WorldWideScience

Sample records for human cadaver study

  1. Use of human cadavers in teaching of human anatomy in brazilian medical faculties

    Directory of Open Access Journals (Sweden)

    Isabela de Sousa Leal Lopes

    2017-05-01

    Full Text Available The Human Anatomy is the study of human body structure and it has been related to the use of cadavers through the history. The aim of this research was to investigate the use of human cadavers in practical classes of human anatomy in Brazilian medical schools, and it was also made the identification of alternative methodologies and new technologies applied to the teaching of Anatomy. The research was conducted at the Faculdade Integral Diferencial from January to December of 2015. The population studied was composed by professors responsible for the Human Anatomy sector of the Brazilian medical faculties. It was addressed all the 242 medical colleges of the Brazil. It was obtained 81 answers. 96% of respondents reported make use of human corpses in its practical lessons of anatomy. It can be observed that 42% of the surveyed medical schools make use of only formaldehyde. 81% of faculties reported to face some difficulties to acquire human cadavers. 84% of medical schools make use of artificial models. 46% of faculties make use of diagnostic images. It can be concluded that human bodies, artificial models and new technologies are widely used in practical classes of anatomy in Brazil, since there is a difficulty to obtain cadavers.

  2. Insect Fauna of Human Cadavers in Tehran District

    Directory of Open Access Journals (Sweden)

    Fahimeh Talebzadeh

    2017-10-01

    Full Text Available Background: Entomological data can provide valuable information for crime scene investigations especially in post- mortem interval (PMI estimation. This study performed to determine insect fauna of human corpses in Tehran dis­trict.Methods: Insect specimens were collected from 12 human cadavers during spring and summer 2014 and were identi­fied using morphological characteristics.Results: Four fly species including two blowflies Chrysomya albiceps and Lucilia sericata (Calliphoridae, one flesh fly Sarcophaga argyrostoma (Sarcophagidae, and one phorid fly Megaselia scalaris (Phoridae and a beetle Der­mestes maculatus (Dermestidae was observed on the human cadavers. Chrysomya albiceps was the most dominant species on the corpses temporally and spatially.Conclusion: Chrysomya albiceps was the most dominant insect species on human cadavers in the area study spatio­temporally. The data make C. albiceps as a valuable entomological indicator for PMI estimation in Tehran and other parts of the country. However, further biological and ecological data such as its behavior, life tables, and consistent developmental time should be investigated when establishing a PMI in the region.

  3. Still Human: A Call for Increased Focus on Ethical Standards in Cadaver Research.

    Science.gov (United States)

    Bach, Michelle C

    2016-12-01

    Research on human cadavers is an important mechanism of scientific progress and comprises a large industry in the United States. However, despite its importance and influence, there is little ethical or regulatory oversight of cadaver-based research. This lack of transparency raises important ethical questions. Thus, this paper serves as a call for ethicists and regulators to pay increased attention to cadaver research. I argue that cadaver research ought to be considered a subset of human subjects research and held accountable to higher ethical standards. After describing current practices, I argue that oversight of cadaver research as a form of human subjects research is appropriate because cadaver research is similar to other types of human research, participants in cadaver research incur risks of harm, and a current lack of oversight has allowed the cadaver industry to entice research participation through ethically questionable practices. This paper urges greater dialogue among human subjects research ethicists and regulators about what constitutes appropriate protections for participants in cadaver research.

  4. Human Cadavers vs. Multimedia Simulation: A Study of Student Learning in Anatomy

    Science.gov (United States)

    Saltarelli, Andrew J.; Roseth, Cary J.; Saltarelli, William A.

    2014-01-01

    Multimedia and simulation programs are increasingly being used for anatomy instruction, yet it remains unclear how learning with these technologies compares with learning with actual human cadavers. Using a multilevel, quasi-experimental-control design, this study compared the effects of "Anatomy and Physiology Revealed" (APR) multimedia…

  5. Anatomical study of prefixed versus postfixed brachial plexuses in adult human cadaver.

    Science.gov (United States)

    Guday, Edengenet; Bekele, Asegedech; Muche, Abebe

    2017-05-01

    The brachial plexus is usually formed by the fusion of anterior primary rami of the fifth to eighth cervical and the first thoracic spinal nerves. Variations in the formation of the brachial plexus may occur. Variations in brachial plexus anatomy are important to radiologists, surgeons and anaesthesiologists performing surgical procedures in the neck, axilla and upper limb regions. These variations may lead to deviation from the expected dermatome distribution as well as differences in the motor innervation of muscles of the upper limb. This study is aimed to describe the anatomical variations of brachial plexus in its formation among 20 Ethiopian cadavers. Observational based study was conducted by using 20 cadavers obtained from the Department of Human Anatomy at University of Gondar, Bahir Dar, Addis Ababa, Hawasa, Hayat Medical College and St Paul Hospital Millennium Medical College. Data analysis was conducted using thematic approaches. A total of 20 cadavers examined bilaterally for the formation of brachial plexus. Of the 40 sides, 30 sides (75%) were found normal, seven sides (17.5%) prefixed, three sides (7.5%) postfixed and one side of the cadaver lacks cord formation. The brachial plexus formation in most subjects is found to be normal. Among the variants, the numbers of the prefixed brachial plexuses are greater than the postfixed brachial plexuses. © 2016 Royal Australasian College of Surgeons.

  6. A human cadaver fascial compartment pressure measurement model.

    Science.gov (United States)

    Messina, Frank C; Cooper, Dylan; Huffman, Gretchen; Bartkus, Edward; Wilbur, Lee

    2013-10-01

    Fresh human cadavers provide an effective model for procedural training. Currently, there are no realistic models to teach fascial compartment pressure measurement. We created a human cadaver fascial compartment pressure measurement model and studied its feasibility with a pre-post design. Three faculty members, following instructions from a common procedure textbook, used a standard handheld intra-compartment pressure monitor (Stryker(®), Kalamazoo, MI) to measure baseline pressures ("unembalmed") in the anterior, lateral, deep posterior, and superficial posterior compartments of the lower legs of a fresh human cadaver. The right femoral artery was then identified by superficial dissection, cannulated distally towards the lower leg, and connected to a standard embalming machine. After a 5-min infusion, the same three faculty members re-measured pressures ("embalmed") of the same compartments on the cannulated right leg. Unembalmed and embalmed readings for each compartment, and baseline readings for each leg, were compared using a two-sided paired t-test. The mean baseline compartment pressures did not differ between the right and left legs. Using the embalming machine, compartment pressure readings increased significantly over baseline for three of four fascial compartments; all in mm Hg (±SD): anterior from 40 (±9) to 143 (±44) (p = 0.08); lateral from 22 (±2.5) to 160 (±4.3) (p cadaver using a standard embalming machine. Set-up is minimal and the model can be incorporated into teaching curricula. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Body composition of two human cadavers by neutron activation and chemical analysis

    International Nuclear Information System (INIS)

    Knight, G.S.; Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1986-01-01

    In vivo neutron activation analysis (NAA) is currently used to measure body composition in metabolic and nutritional studies in many clinical situations, but has not previously been validated by comparison with chemical analysis of human cadavers. Total body nitrogen (TBN) and chlorine (TBCl) were measured in two human cadavers by NAA before homogenization and chemical analysis (CHEM) after (cadaver 1: TBN, 1.47 NAA, 1.51 CHEM; TBCl, 0.144 NAA, 0.147 CHEM; cadaver 2: TBN, 0.576 NAA, 0.572 CHEM; TBCl, 0.0227 NAA, 0.0250 CHEM). The homogenates were also analyzed by NAA, and no significant differences were found, indicating that the effects of elemental inhomogeneity on the measurement of TBN and TBCl are insignificant. Total body water, fat, protein, minerals, and carbohydrates were measured chemically for each cadaver and compared with estimates for these compartments obtained from a body composition model, which when used in vivo involves NAA and tritium dilution. The agreement found justifies the use of the model for the measurement of changes in total body protein, water, and fat in sequential studies in groups of patients

  8. The ethics of human cadaver organ transplantation: a biologist's viewpoint.

    Science.gov (United States)

    Emson, H E

    1987-01-01

    The rights of the various individuals involved in decision-making in cadaver organ donation are considered, and there is discussion of the relation of human cadavers to the planetary biomass. I conclude that the rights of the potential recipient should outweigh those of the other parties concerned and that education and legislation should recognise and promote this. PMID:3669037

  9. Using ATP-driven bioluminescence assay to monitor microbial safety in a contemporary human cadaver laboratory.

    Science.gov (United States)

    Benninger, Brion; Maier, Thomas

    2015-03-01

    The objective of this study was to utilize a cost-effective method for assessing the levels of bacterial, yeast, and mold activity during a human dissection laboratory course. Nowadays, compliance with safety regulations is policed by institutions at higher standards than ever before. Fear of acquiring an unknown infection is one of the top concerns of professional healthcare students, and it provokes anti-laboratory anxiety. Human cadavers are not routinely tested for bacteria and viruses prior to embalming. Human anatomy dissecting rooms that house embalmed cadavers are normally cleaned after the dissected cadavers have been removed. There is no evidence that investigators have ever assessed bacterial and fungal activities using adenosine triphosphate (ATP)-driven bioluminescence assays. A literature search was conducted on texts, journals, and websites regarding bacterial, yeast, and mold activities in an active cadaver laboratory. Midway into a clinical anatomy course, ATP bioluminescence assays were used to swab various sites within the dissection room, including entrance and exiting door handles, water taps, cadaver tables, counter tops, imaging material, X-ray box switches, and the cadaver surfaces. The results demonstrated very low activities on cadaver tables, washing up areas, and exiting door handles. There was low activity on counter tops and X-ray boxes. There was medium activity on the entrance door handles. These findings suggest an inexpensive and accurate method for monitoring safety compliance and microbial activity. Students can feel confident and safe in the environment in which they work. © 2014 Wiley Periodicals, Inc.

  10. Human Cadaver Material in Preclinical Oral Surgery.

    Science.gov (United States)

    Barber, H. Dexter; And Others

    1993-01-01

    A University of Michigan dental school curriculum for oral surgery that uses human cadaver heads is described. Selection, preparation, and laboratory use of the materials are outlined. Faculty and students have received the sequence well and found it prepared them for clinical rotation. (MSE)

  11. Displacement of the medial meniscus within the passive motion characteristics of the human knee joint: an RSA study in human cadaver knees.

    NARCIS (Netherlands)

    Tienen, T. van; Buma, P.; Scholten, J.G.; Kampen, A. van; Veth, R.P.H.; Verdonschot, N.J.J.

    2005-01-01

    The objective of this study was to validate an in vitro human cadaver knee-joint model for the evaluation of the meniscal movement during knee-joint flexion. The question was whether our model showed comparable meniscal displacements to those found in earlier meniscal movement studies in vivo.

  12. Femtosecond laser subsurface scleral treatment in cadaver human sclera and evaluation using two-photon and confocal microscopy

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Yan, Ying; Lian, Fuqiang; Kurtz, Ron; Juhasz, Tibor

    2016-03-01

    Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial-thickness drainage channels can be created with femtosecond laser in the translucent sclera for the potential treatment of glaucoma. We demonstrate the creation of partial-thickness subsurface drainage channels with the femtosecond laser in the cadaver human eyeballs and describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. A femtosecond laser operating at a wavelength of 1700 nm was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of cadaver human eyes. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such partial thickness subsurface scleral channels. Our studies suggest that the confocal and two-photon microscopy can be used to investigate femtosecond-laser created partial-thickness drainage channels in the sclera of cadaver human eyes.

  13. Laparoscopic training model using fresh human cadavers without the establishment of penumoperitoneum

    Directory of Open Access Journals (Sweden)

    Ernesto Sasaki Imakuma

    2016-01-01

    Full Text Available Background: Laparoscopy is a well-established alternative to open surgery for treating many diseases. Although laparoscopy has many advantages, it is also associated with disadvantages, such as slow learning curves and prolonged operation time. Fresh frozen cadavers may be an interesting resource for laparoscopic training, and many institutions have access to cadavers. One of the main obstacles for the use of cadavers as a training model is the difficulty in introducing a sufficient pneumoperitoneum to distend the abdominal wall and provide a proper working space. The purpose of this study was to describe a fresh human cadaver model for laparoscopic training without requiring a pneumoperitoneum. Materials and Methods and Results: A fake abdominal wall device was developed to allow for laparoscopic training without requiring a pneumoperitoneum in cadavers. The device consists of a table-mounted retractor, two rail clamps, two independent frame arms, two adjustable handle and rotating features, and two frames of the abdominal wall. A handycam is fixed over a frame arm, positioned and connected through a USB connection to a television and dissector; scissors and other laparoscopic materials are positioned inside trocars. The laparoscopic procedure is thus simulated. Conclusion: Cadavers offer a very promising and useful model for laparoscopic training. We developed a fake abdominal wall device that solves the limitation of space when performing surgery on cadavers and removes the need to acquire more costly laparoscopic equipment. This model is easily accessible at institutions in developing countries, making it one of the most promising tools for teaching laparoscopy.

  14. Applied anatomic study of testicular veins in adult cadavers and in human fetuses

    Directory of Open Access Journals (Sweden)

    Luciano A. Favorito

    2007-04-01

    Full Text Available OBJECTIVES: Analyze the anatomic variations of the testicular veins in human cadavers and fetuses. MATERIALS AND METHODS: One hundred male adult cadavers and 24 fetuses were studied. Four anatomic aspects were considered: 1 Number of testicular veins, 2 The local of vein termination, 3 Type and number of collaterals present and 4 Testicular vein termination angle. RESULTS: Cadavers - Right side - One testicular vein occurred in 85% and 2 veins in 5% of the cases. There were communicating veins with the colon in 21% of the cases. Left side - One testicular vein occurred in 82%, two veins in 15%, three veins in 2% and four veins in 1% of the cases. There were communicating veins with the colon in 31% of the cases. Fetuses - Right side -One testicular vein occurred in all cases. This vein drained to the vena cava in 83.3% of the cases, to the junction of the vena cava with the renal vein in 12.5% and to the renal vein in 4.2%. There were communicating veins with the colon in 25% of the cases. Left side - One testicular vein occurred in 66.6% of the cases, and 2 veins in occurred 33.3%. Communicating veins with the colon were found in 41.6% of the cases. CONCLUSION: The testicular vein presents numeric variations and also variations in its local of termination. In approximately 30% of the cases, there are collaterals that communicate the testicular vein with retroperitoneal veins. These anatomic findings can help understanding the origin of varicocele and its recurrence after surgical interventions.

  15. Morphometric Study of Vocal Folds in Indian Cadavers

    Directory of Open Access Journals (Sweden)

    Rawal J.D.

    2015-06-01

    Full Text Available Introduction: -The larynx is an air passage and a sphincteric device used in respiration and phonation. The larynx, from inside outwards has a framework of mucosa surrounded by fibro-elastic membrane which in turn is surrounded by cartilages and then a layer of muscles. Vocal folds are intrinsic ligament of larynx covered by mucosal folds. Larynx generates sound through rhythmic opening and closing of the vocal folds. The perceived pitch of human voice mainly depends upon fundamental frequency of sound generated by larynx. Aim: - The aim of present study is to measure various dimensions of vocal folds in Indian cadavers. Material & Methods: - 50 larynx were obtained from embalmed cadavers, of which 10 larynx were of females. Vocal cords were dissected from the larynx and morphometric analysis was done. Results and Conclusions: - The average total length of the vocal folds was found to be 16.11 mm. ± 2.62 mm. in male and 14.10 mm. ± 1.54 mm. in female cadavers. The average width of the vocal folds was found to be 4.38 mm. ± 0.74 mm. in male and 3.60 mm. ± 0.64 mm. in female cadavers. The average total length of the membranous part of the vocal folds was found to be 11.90 mm. ± 1.86 mm. in male and 10.45 mm. ± 1.81 mm. in female cadavers. The average ratio of the length of the membranous and the cartilaginous parts of the vocal folds was calculated to be 3.10 ± 0.96in male and 2.85 ± 0.73in female cadavers.

  16. Successful transplantation of in vitro expanded human cadaver corneal endothelial precursor cells on to a cadaver bovine's eye using a nanocomposite gel sheet.

    Science.gov (United States)

    Parikumar, Periyasamy; Haraguchi, Kazutoshi; Ohbayashi, Akira; Senthilkumar, Rajappa; Abraham, Samuel J K

    2014-05-01

    In vitro expansion of human corneal endothelial precursor (HCEP) cells has been reported via production of cell aggregated spheres. However, to translate this procedure in human patients warrants maintaining the position of the eyeballs facing down for 36 h, which is not feasible. In this study, we report a method using a nanocomposite (NC) gel sheet to accomplish the integration of HCEP cells to the endothelium of cadaver bovine's eyes. HCEP cells were isolated from the corneal endothelium of a cadaver human eye and then expanded using a thermoreversible gelation polymer (TGP) as reported earlier. For the study, three cadaver bovine eyes were used. The NC gel sheets were inserted into the bovine eyes', aligned and suture-fixed in position under the host endothelium. HCEP cells previously expanded in the TGP were harvested and injected using a 26-gauge syringe between the endothelium and the NC gel sheet. The eyes were left undisturbed for three hours following which the NC gel sheets were gently removed. The corneas were harvested and subjected to histopathological studies. Histopathological studies showed that all the three corneas used for NC gel sheet implantation showed the presence of engrafted HCEP cells, seen as multi-layered cells over the native endothelium of the bovine cornea. Examination of the NC gel sheets used for implantation showed that only very few corneal endothelial cells remained on the sheets amounting to what could be considered negligible. The use of the NC gel sheet makes HCEP cell transplantation feasible for human patients. Further in vitro basic studies followed by translational studies are necessary to bring this method for clinical application in appropriate indications.

  17. Evaluation of automatic image quality assessment in chest CT - A human cadaver study.

    Science.gov (United States)

    Franck, Caro; De Crop, An; De Roo, Bieke; Smeets, Peter; Vergauwen, Merel; Dewaele, Tom; Van Borsel, Mathias; Achten, Eric; Van Hoof, Tom; Bacher, Klaus

    2017-04-01

    The evaluation of clinical image quality (IQ) is important to optimize CT protocols and to keep patient doses as low as reasonably achievable. Considering the significant amount of effort needed for human observer studies, automatic IQ tools are a promising alternative. The purpose of this study was to evaluate automatic IQ assessment in chest CT using Thiel embalmed cadavers. Chest CT's of Thiel embalmed cadavers were acquired at different exposures. Clinical IQ was determined by performing a visual grading analysis. Physical-technical IQ (noise, contrast-to-noise and contrast-detail) was assessed in a Catphan phantom. Soft and sharp reconstructions were made with filtered back projection and two strengths of iterative reconstruction. In addition to the classical IQ metrics, an automatic algorithm was used to calculate image quality scores (IQs). To be able to compare datasets reconstructed with different kernels, the IQs values were normalized. Good correlations were found between IQs and the measured physical-technical image quality: noise (ρ=-1.00), contrast-to-noise (ρ=1.00) and contrast-detail (ρ=0.96). The correlation coefficients between IQs and the observed clinical image quality of soft and sharp reconstructions were 0.88 and 0.93, respectively. The automatic scoring algorithm is a promising tool for the evaluation of thoracic CT scans in daily clinical practice. It allows monitoring of the image quality of a chest protocol over time, without human intervention. Different reconstruction kernels can be compared after normalization of the IQs. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. A pilot study comparing the use of Thiel- and formalin-embalmed cadavers in the teaching of human anatomy.

    Science.gov (United States)

    Balta, Joy Y; Lamb, Clare; Soames, Roger W

    2015-01-01

    Formalin had traditionally been used to preserve human material to teach gross anatomy. In 2008 the Centre for Anatomy and Human Identification (CAHID) at the University of Dundee embarked on the use of the Thiel method of embalming. The aim of this pilot study was to assess the difference between formalin-embalmed cadavers (FEC) and Thiel-embalmed cadavers (TEC) used for teaching and surgical training. Three different questionnaires were prepared for data collection from undergraduate and postgraduate students and clinical staff. All undergraduate and postgraduate students as well as clinical staff commented on the appearance of the TEC. There was no overall consensus concerning the use of TEC, some respondents preferred TEC for the entire dissection, some only for certain areas such as the musculoskeletal system. On a technical level TEC were considered less hazardous then FEC by one-third of participants with fewer than 10% regarding TEC as more irritating than FEC. Psychologically, 32.7% of undergraduate students expressed the view that TEC made them feel more uncomfortable compared with FEC because of their life-like appearance. However, 57.1% of undergraduate students encountered the same uncomfortable feelings when viewing both TEC and FEC. The use of Thiel-embalmed cadavers to teach anatomy has an added value, though further research is required over longer periods of time to identify its best usage. © 2014 American Association of Anatomists.

  19. Soul Anatomy: A virtual cadaver

    Directory of Open Access Journals (Sweden)

    Moaz Bambi

    2014-01-01

    Full Text Available In the traditional science of medicine and medical education, teaching human anatomy in the class has always been done using human cadavers. Not only does this violate human sanctity, but according to our research, it is not adequate to provide students with the alleged educational value that it is supposed to deliver. It is very cumbersome to organise all the aspects of cadaver care. Cadavers are also very limited when it comes to controlling their structures and any benefit is almost completely altered the first time the cadaver is used (dissected, and ironically, it is very weak at delivering actual real-life scenarios of a human body to students. Virtual anatomy has been a promising solution that many are counting on. But even today, we have not found a complete solution that combines all the benefits of using human cadavers and those introduced by its technical counterparts. "Soul Anatomy" aims to do just that. It brings the best of all worlds, from a natural intuitive control system, life-like feel of organs, precise accuracy in moving and controlling bodily structures, to the smallest details of being able to show medical information overlays from various medical databases connected to the internet; thus making use of technology in teaching human anatomy by providing a modern learning experience.

  20. Quantitative analysis of transcranial and intraparenchymal light penetration in human cadaver brain tissue.

    Science.gov (United States)

    Tedford, Clark E; DeLapp, Scott; Jacques, Steven; Anders, Juanita

    2015-04-01

    Photobiomodulation (PBM) also known as low-level light therapy has been used successfully for the treatment of injury and disease of the nervous system. The use of PBM to treat injury and diseases of the brain requires an in-depth understanding of light propagation through tissues including scalp, skull, meninges, and brain. This study investigated the light penetration gradients in the human cadaver brain using a Transcranial Laser System with a 30 mm diameter beam of 808 nm wavelength light. In addition, the wavelength-dependence of light scatter and absorbance in intraparenchymal brain tissue using 660, 808, and 940 nm wavelengths was investigated. Intact human cadaver heads (n = 8) were obtained for measurement of light propagation through the scalp/skull/meninges and into brain tissue. The cadaver heads were sectioned in either the transverse or mid-sagittal. The sectioned head was mounted into a cranial fixture with an 808 nm wavelength laser system illuminating the head from beneath with either pulsed-wave (PW) or continuous-wave (CW) laser light. A linear array of nine isotropic optical fibers on a 5 mm pitch was inserted into the brain tissue along the optical axis of the beam. Light collected from each fiber was delivered to a multichannel power meter. As the array was lowered into the tissue, the power from each probe was recorded at 5 mm increments until the inner aspect of the dura mater was reached. Intraparenchymal light penetration measurements were made by delivering a series of wavelengths (660, 808, and 940 nm) through a separate optical fiber within the array, which was offset from the array line by 5 mm. Local light penetration was determined and compared across the selected wavelengths. Unfixed cadaver brains provide good anatomical localization and reliable measurements of light scatter and penetration in the CNS tissues. Transcranial application of 808 nm wavelength light penetrated the scalp, skull, meninges, and brain

  1. Prediction and analysis of human thoracic impact responses and injuries in cadaver impacts using a full human body finite element model.

    Science.gov (United States)

    Ruan, Jesse; El-Jawahri, Raed; Chai, Li; Barbat, Saeed; Prasad, Priya

    2003-10-01

    Human thoracic dynamic responses and injuries associated with frontal impact, side impact, and belt loading were investigated and predicted using a complete human body finite element model for an average adult male. The human body model was developed to study the impact biomechanics of a vehicular occupant. Its geometry was based on the Visible Human Project (National Library of Medicine) and the topographies from human body anatomical texts. The data was then scaled to an average adult male according to available biomechanical data from the literature. The model includes details of the head, neck, ribcage, abdomen, thoracic and lumbar spine, internal organs of the chest and abdomen, pelvis, and the upper and lower extremities. The present study is focused on the dynamic response and injuries of the thorax. The model was validated at various impact speeds by comparing predicted responses with available experimental cadaver data in frontal and side pendulum impacts, as well as belt loading. Model responses were compared with similar individual cadaver tests instead of using cadaver corridors because the large differences between the upper and lower bounds of the corridors may confound the model validation. The validated model was then used to study thorax dynamic responses and injuries in various simulated impact conditions. Parameters that could induce injuries such as force, deflection, and stress were computed from model simulations and were compared with previously proposed thoracic injury criteria to assess injury potential for the thorax. It has been shown that the model exhibited speed sensitive impact characteristics, and the compressibility of the internal organs significantly influenced the overall impact response in the simulated impact conditions. This study demonstrates that the development of a validated FE human body model could be useful for injury assessment in various cadaveric impacts reported in the literature. Internal organ injuries, which are

  2. Emotional response of undergraduates to cadaver dissection.

    Science.gov (United States)

    Wisenden, Patricia A; Budke, Katherine J; Klemetson, Chelsea J; Kurtti, Tana R; Patel, Chandi M; Schwantz, Trenda L; Wisenden, Brian D

    2018-03-01

    The most effective way to learn human anatomy is through cadaver dissection. Historically, cadaver dissection has been the provenance of professional schools. Increasingly, cadaver-based courses in human anatomy are shifting to the undergraduate level, which creates both problems and opportunities because of differences between undergraduate and graduate student populations. Anxiety associated with dissecting cadavers can create a barrier to learning, and ultimately, entry into the health and medical sciences for some demographic subpopulations of undergraduates. We surveyed 76 students in 2007 and 51 students in 2009 at four times in the semester to investigate the timing and sociodemographic predictors of anxiety over cadaver dissection. We followed this with a second survey of 44 students in 2014 to test the effect of humanization of cadaver donors (providing information about donor occupation and cause of death) to reduce student anxiety. Students experienced anxiety upon first exposure to cadaver dissection. Female students experienced greater anxiety than male students upon first exposure to cadavers but this effect was short-lived. Self-identified non-white, non-Christian students experienced sustained anxiety throughout the semester, likely because cadaver stress compounded social and financial stressors unique to international students. Humanization was effective in reducing anxiety in non-white, non-Christian students but had the unexpected effect of increasing anxiety in female students. We recommend that humanizing information be offered to students who seek it out, but not forced upon students for whom the information would only add to their stress. Clin. Anat. 31:224-230, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Construct Validity of Fresh Frozen Human Cadaver as a Training Model in Minimal Access Surgery

    Science.gov (United States)

    Macafee, David; Pranesh, Nagarajan; Horgan, Alan F.

    2012-01-01

    Background: The construct validity of fresh human cadaver as a training tool has not been established previously. The aims of this study were to investigate the construct validity of fresh frozen human cadaver as a method of training in minimal access surgery and determine if novices can be rapidly trained using this model to a safe level of performance. Methods: Junior surgical trainees, novices (cadavers. Expert laparoscopists (>100 laparoscopic procedures) performed 3 repetitions of identical tasks. Performances were scored using a validated, objective Global Operative Assessment of Laparoscopic Skills scale. Scores for 3 consecutive repetitions were compared between experts and novices to determine construct validity. Furthermore, to determine if the novices reached a safe level, a trimmed mean of the experts score was used to define a benchmark. Mann-Whitney U test was used for construct validity analysis and 1-sample t test to compare performances of the novice group with the benchmark safe score. Results: Ten novices and 2 experts were recruited. Four out of 5 tasks (nondominant to dominant hand transfer; simulated appendicectomy; intracorporeal and extracorporeal knot tying) showed construct validity. Novices’ scores became comparable to benchmark scores between the eighth and tenth repetition. Conclusion: Minimal access surgical training using fresh frozen human cadavers appears to have construct validity. The laparoscopic skills of novices can be accelerated through to a safe level within 8 to 10 repetitions. PMID:23318058

  4. History and future of human cadaver preservation for surgical training: from formalin to saturated salt solution method.

    Science.gov (United States)

    Hayashi, Shogo; Naito, Munekazu; Kawata, Shinichi; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Itoh, Masahiro

    2016-01-01

    Traditionally, surgical training meant on-the-job training with live patients in an operating room. However, due to advancing surgical techniques, such as minimally invasive surgery, and increasing safety demands during procedures, human cadavers have been used for surgical training. When considering the use of human cadavers for surgical training, one of the most important factors is their preservation. In this review, we summarize four preservation methods: fresh-frozen cadaver, formalin, Thiel's, and saturated salt solution methods. Fresh-frozen cadaver is currently the model that is closest to reality, but it also presents myriad problems, including the requirement of freezers for storage, limited work time because of rapid putrefaction, and risk of infection. Formalin is still used ubiquitously due to its low cost and wide availability, but it is not ideal because formaldehyde has an adverse health effect and formalin-embalmed cadavers do not exhibit many of the qualities of living organs. Thiel's method results in soft and flexible cadavers with almost natural colors, and Thiel-embalmed cadavers have been appraised widely in various medical disciplines. However, Thiel's method is relatively expensive and technically complicated. In addition, Thiel-embalmed cadavers have a limited dissection time. The saturated salt solution method is simple, carries a low risk of infection, and is relatively low cost. Although more research is needed, this method seems to be sufficiently useful for surgical training and has noteworthy features that expand the capability of clinical training. The saturated salt solution method will contribute to a wider use of cadavers for surgical training.

  5. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  6. Transformation of a Cadaver Population: Analysis of a South African Cadaver Program, 1921-2013

    Science.gov (United States)

    Kramer, Beverley; Hutchinson, Erin F.

    2015-01-01

    Anatomy has served as a cornerstone in the training of various allied and clinical disciplines and has traditionally been based on dissection of the human body. Thus, to pursue this method of teaching and learning, access to cadavers is of continuing importance. Over a significant period of time unclaimed cadavers have performed an essential role…

  7. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study.

    Science.gov (United States)

    De Crop, An; Bacher, Klaus; Van Hoof, Tom; Smeets, Peter V; Smet, Barbara S; Vergauwen, Merel; Kiendys, Urszula; Duyck, Philippe; Verstraete, Koenraad; D'Herde, Katharina; Thierens, Hubert

    2012-01-01

    To determine the correlation between the clinical and physical image quality of chest images by using cadavers embalmed with the Thiel technique and a contrast-detail phantom. The use of human cadavers fulfilled the requirements of the institutional ethics committee. Clinical image quality was assessed by using three human cadavers embalmed with the Thiel technique, which results in excellent preservation of the flexibility and plasticity of organs and tissues. As a result, lungs can be inflated during image acquisition to simulate the pulmonary anatomy seen on a chest radiograph. Both contrast-detail phantom images and chest images of the Thiel-embalmed bodies were acquired with an amorphous silicon flat-panel detector. Tube voltage (70, 81, 90, 100, 113, 125 kVp), copper filtration (0.1, 0.2, 0.3 mm Cu), and exposure settings (200, 280, 400, 560, 800 speed class) were altered to simulate different quality levels. Four experienced radiologists assessed the image quality by using a visual grading analysis (VGA) technique based on European Quality Criteria for Chest Radiology. The phantom images were scored manually and automatically with use of dedicated software, both resulting in an inverse image quality figure (IQF). Spearman rank correlations between inverse IQFs and VGA scores were calculated. A statistically significant correlation (r = 0.80, P chest radiography. © RSNA, 2011.

  8. Development of a human cadaver model for training in laparoscopic donor nephrectomy.

    Science.gov (United States)

    Sutton, Erica R H; Billeter, Adrian; Druen, Devin; Roberts, Henry; Rice, Jonathan

    2017-06-01

    The organ procurement network recommends a surgeon record 15 cases as surgeon or assistant for laparoscopic donor nephrectomies (LDN) prior to independent practice. The literature suggests that the learning curve for improved perioperative and patient outcomes is closer to 35 cases. In this article, we describe our development of a model utilizing fresh tissue and objective, quantifiable endpoints to document surgical progress, and efficiency in each of the major steps involved in LDN. Phase I of model development focused on the modifications necessary to maintain visualization for laparoscopic surgery in a human cadaver. Phase II tested proposed learner-based metrics of procedural competency for multiport LDN by timing procedural steps of LDN in a novice learner. Phases I and II required 12 and nine cadavers, with a total of 35 kidneys utilized. The following metrics improved with trial number for multiport LDN: time taken for dissection of the gonadal vein, ureter, renal hilum, adrenal and lumbrical veins, simulated warm ischemic time (WIT), and operative time. Human cadavers can be used for training in LDN as evidenced by improvements in timed learner-based metrics. This simulation-based model fills a gap in available training options for surgeons. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Flies (Calliphoridae, Muscidae and Beetles (Silphidae from Human Cadavers in Cali, Colombia

    Directory of Open Access Journals (Sweden)

    Barreto Mauricio

    2002-01-01

    Full Text Available Adult specimens of Cochliomyia macellaria, Chrysomya megacephala, Ch. rufifacies, Lucilia sp. (Calliphoridae, Musca domestica (Muscidae, Oxelytrum discicolle (Silphidae and Sarcophagidae were recovered from 12 human cadavers in Cali, Valle, Colombia. Information regarding these findings is presented.

  10. Student Perceptions of an Upper-Level, Undergraduate Human Anatomy Laboratory Course without Cadavers

    Science.gov (United States)

    Wright, Shirley J.

    2012-01-01

    Several programs in health professional education require or are considering requiring upper-level human anatomy as prerequisite for their applicants. Undergraduate students are confronted with few institutions offering such a course, in part because of the expense and logistical issues associated with a cadaver-based human anatomy course. This…

  11. A Qualitative Assessment of Human Cadavers Embalmed by Thiel's Method Used in Laparoscopic Training for Renal Resection

    Science.gov (United States)

    Rai, Bhavan Prasad; Tang, Benjie; Eisma, Roos; Soames, Roger W.; Wen, Haitao; Nabi, Ghulam

    2012-01-01

    Human cadaveric tissue is the fundamental substrate for basic anatomic and surgical skills training. A qualitative assessment of the use of human cadavers preserved by Thiel's method for a British Association of Urological Surgeons--approved, advanced laparoscopic renal resection skills training course is described in the present study. Four…

  12. The Utility of Cadaver-Based Approaches for the Teaching of Human Anatomy: A Survey of British and Irish Anatomy Teachers

    Science.gov (United States)

    Balta, Joy Y.; Cronin, Michael; Cryan, John F.; O'Mahony, Siobhain M.

    2017-01-01

    Utilizing reality anatomy such as dissection and demonstrating using cadavers has been described as a superior way to create meaning. The chemicals used to embalm cadavers differentially alter the tissue of the human body, which has led to the usage of different processes along the hard to soft-fixed spectrum of preserved cadavers. A questionnaire…

  13. Schneiderian membrane detachment using transcrestal hydrodynamic ultrasonic cavitational sinus lift: a human cadaver head study and histologic analysis.

    Science.gov (United States)

    Troedhan, Angelo; Kurrek, Andreas; Wainwright, Marcel; Jank, Siegfried

    2014-08-01

    Recent studies have suggested the osteogenic layer of the periosteum at the base of the sinus membrane to play a key role in bone regeneration after sinus lift procedures. Thus, atraumatic detachment of the sinus membrane with an intact periosteum seems mandatory. The present histologic study of fresh human cadaver heads investigated the detachment behavior and histologic integrity of the detached periosteum after application of the transcrestal hydrodynamic ultrasonic cavitational sinus lift (tHUCSL-INTRALIFT). A total of 15 sinuses in 8 fresh human cadaver heads were treated using tHUCSL-INTRALIFT. After surgery, they were checked macroscopically for damage to the sinus membrane and then processed for histologic inspection under light microscopy. A total of 150 histologic specimens, randomly selected from the core surgical sites, were investigated using hematoxylin-eosin (HE), Azan, and trichrome staining. None of the 150 inspected specimens showed any perforation or dissection of the periosteum from the subepithelial connective tissue and respiratory epithelium and were fully detached from the bony antrum floor. The connecting Sharpey fibers revealed to be cleanly separated from the sinus floor in all specimens. The results of the present study suggest tHUCSL-INTRALIFT should be used to perform predictable and safe detachment of the periosteum from the bony sinus floor as a prerequisite for undisturbed and successful physiologic subantral bone regeneration. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Accuracy of computer-guided implantation in a human cadaver model.

    Science.gov (United States)

    Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi

    2015-10-01

    To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  15. Anatomic study of celiac ganglia using CT in cadavers

    International Nuclear Information System (INIS)

    Zhao Qionghui; Zhang Xiaoming; Zeng Nanlin; Cai Changping; Xie Xingguo; Li Chengjun

    2005-01-01

    Objective: To identify the celiac ganglia in cadavers by using current CT techniques, and to facilitate its identification in vivo by CT. Methods: Fifty cadavers were dissected, moving peritoneal organs such as liver and stomach to expose the celiac ganglia. The location, morphology, and dimensions of celiac ganglia, and their relationship to abutting structures, were noted. The celiac ganglia in 6 of the 50 cadavers without peripancreatic diseases and with clear anatomy were isolated and marked with yellow dye and Iohexol injection. In these 6 cadavers, the moved organs were relocated, the abdomen was closed, and CT was performed. CT derived measurements of celiac ganglia were compared with those from cadavers study. Results: The celiac ganglia of 47 of 50 cadavers (94%) were located between T12-L1, and those of 3 cadavers (6%) were located between T11-12. The superior-inferior diameter of the right ganglia was (25.01 ±6.09) mm, long (left-right) diameter was (13.18 ± 3.62) mm, and short (thickness) diameter was (1.40 ± 0.55) mm. In the left ganglia, these three diameters were (22.74 ± 5.70) mm, (15.07 ± 4.35) mm, and (2.00 ± 0.71 ) mm, respectively. On the CT images of 6 cadavers, the right and left ganglia were all identified and were hyperdense relative to viscus, such as liver and spleen. The long and short diameters on CT images were (15.20 ± 1.64) mm and (1.53 ± 0.52) mm for the right ganglia and (16.25 ± 1.73 ) mm and (2.20 ± 0.73) mm for the left ganglia. There was no significant difference between the diameters of the ganglia measured on CT images and by dissection (P>0.05). Conclusion: Current CT techniques can demonstrate accurately the celiac ganglia in cadavers. This can be a reference for identifying the celiac plexus in vivo. (authors)

  16. Portal placement in elbow arthroscopy by novice surgeons: cadaver study.

    Science.gov (United States)

    Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N

    2017-07-01

    In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p cadaver instruction session alone. Level of evidence V.

  17. Temporal and Spatial Impact of Human Cadaver Decomposition on Soil Bacterial and Arthropod Community Structure and Function

    Science.gov (United States)

    Singh, Baneshwar; Minick, Kevan J.; Strickland, Michael S.; Wickings, Kyle G.; Crippen, Tawni L.; Tarone, Aaron M.; Benbow, M. Eric; Sufrin, Ness; Tomberlin, Jeffery K.; Pechal, Jennifer L.

    2018-01-01

    As vertebrate carrion decomposes, there is a release of nutrient-rich fluids into the underlying soil, which can impact associated biological community structure and function. How these changes alter soil biogeochemical cycles is relatively unknown and may prove useful in the identification of carrion decomposition islands that have long lasting, focal ecological effects. This study investigated the spatial (0, 1, and 5 m) and temporal (3–732 days) dynamics of human cadaver decomposition on soil bacterial and arthropod community structure and microbial function. We observed strong evidence of a predictable response to cadaver decomposition that varies over space for soil bacterial and arthropod community structure, carbon (C) mineralization and microbial substrate utilization patterns. In the presence of a cadaver (i.e., 0 m samples), the relative abundance of Bacteroidetes and Firmicutes was greater, while the relative abundance of Acidobacteria, Chloroflexi, Gemmatimonadetes, and Verrucomicrobia was lower when compared to samples at 1 and 5 m. Micro-arthropods were more abundant (15 to 17-fold) in soils collected at 0 m compared to either 1 or 5 m, but overall, micro-arthropod community composition was unrelated to either bacterial community composition or function. Bacterial community structure and microbial function also exhibited temporal relationships, whereas arthropod community structure did not. Cumulative precipitation was more effective in predicting temporal variations in bacterial abundance and microbial activity than accumulated degree days. In the presence of the cadaver (i.e., 0 m samples), the relative abundance of Actinobacteria increased significantly with cumulative precipitation. Furthermore, soil bacterial communities and C mineralization were sensitive to the introduction of human cadavers as they diverged from baseline levels and did not recover completely in approximately 2 years. These data are valuable for understanding ecosystem

  18. Temporal and Spatial Impact of Human Cadaver Decomposition on Soil Bacterial and Arthropod Community Structure and Function

    Directory of Open Access Journals (Sweden)

    Baneshwar Singh

    2018-01-01

    Full Text Available As vertebrate carrion decomposes, there is a release of nutrient-rich fluids into the underlying soil, which can impact associated biological community structure and function. How these changes alter soil biogeochemical cycles is relatively unknown and may prove useful in the identification of carrion decomposition islands that have long lasting, focal ecological effects. This study investigated the spatial (0, 1, and 5 m and temporal (3–732 days dynamics of human cadaver decomposition on soil bacterial and arthropod community structure and microbial function. We observed strong evidence of a predictable response to cadaver decomposition that varies over space for soil bacterial and arthropod community structure, carbon (C mineralization and microbial substrate utilization patterns. In the presence of a cadaver (i.e., 0 m samples, the relative abundance of Bacteroidetes and Firmicutes was greater, while the relative abundance of Acidobacteria, Chloroflexi, Gemmatimonadetes, and Verrucomicrobia was lower when compared to samples at 1 and 5 m. Micro-arthropods were more abundant (15 to 17-fold in soils collected at 0 m compared to either 1 or 5 m, but overall, micro-arthropod community composition was unrelated to either bacterial community composition or function. Bacterial community structure and microbial function also exhibited temporal relationships, whereas arthropod community structure did not. Cumulative precipitation was more effective in predicting temporal variations in bacterial abundance and microbial activity than accumulated degree days. In the presence of the cadaver (i.e., 0 m samples, the relative abundance of Actinobacteria increased significantly with cumulative precipitation. Furthermore, soil bacterial communities and C mineralization were sensitive to the introduction of human cadavers as they diverged from baseline levels and did not recover completely in approximately 2 years. These data are valuable for understanding

  19. Coordinated Multiple Cadaver Use for Minimally Invasive Surgical Training

    Science.gov (United States)

    Blaschko, Sarah D.; Brooks, H. Mark; Dhuy, S. Michael; Charest-Shell, Cynthia; Clayman, Ralph V.

    2007-01-01

    Background: The human cadaver remains the gold standard for anatomic training and is highly useful when incorporated into minimally invasive surgical training programs. However, this valuable resource is often not used to its full potential due to a lack of multidisciplinary cooperation. Herein, we propose the coordinated multiple use of individual cadavers to better utilize anatomical resources and potentiate the availability of cadaver training. Methods: Twenty-two postgraduate surgeons participated in a robot-assisted surgical training course that utilized shared cadavers. All participants completed a Likert 4-scale satisfaction questionnaire after their training session. Cadaveric tissue quality and the quality of the training session related to this material were assessed. Results: Nine participants rated the quality of the cadaveric tissue as excellent, 7 as good, 5 as unsatisfactory, and 1 as poor. Overall, 72% of participants who operated on a previously used cadaver were satisfied with their training experience and did not perceive the previous use deleterious to their training. Conclusion: The coordinated use of cadavers, which allows for multiple cadaver use for different teaching sessions, is an excellent training method that increases availability of human anatomical material for minimally invasive surgical training. PMID:18237501

  20. Functional and Structural Succession of Soil Microbial Communities below Decomposing Human Cadavers

    Science.gov (United States)

    Cobaugh, Kelly L.; Schaeffer, Sean M.; DeBruyn, Jennifer M.

    2015-01-01

    The ecological succession of microbes during cadaver decomposition has garnered interest in both basic and applied research contexts (e.g. community assembly and dynamics; forensic indicator of time since death). Yet current understanding of microbial ecology during decomposition is almost entirely based on plant litter. We know very little about microbes recycling carcass-derived organic matter despite the unique decomposition processes. Our objective was to quantify the taxonomic and functional succession of microbial populations in soils below decomposing cadavers, testing the hypotheses that a) periods of increased activity during decomposition are associated with particular taxa; and b) human-associated taxa are introduced to soils, but do not persist outside their host. We collected soils from beneath four cadavers throughout decomposition, and analyzed soil chemistry, microbial activity and bacterial community structure. As expected, decomposition resulted in pulses of soil C and nutrients (particularly ammonia) and stimulated microbial activity. There was no change in total bacterial abundances, however we observed distinct changes in both function and community composition. During active decay (7 - 12 days postmortem), respiration and biomass production rates were high: the community was dominated by Proteobacteria (increased from 15.0 to 26.1% relative abundance) and Firmicutes (increased from 1.0 to 29.0%), with reduced Acidobacteria abundances (decreased from 30.4 to 9.8%). Once decay rates slowed (10 - 23 d postmortem), respiration was elevated, but biomass production rates dropped dramatically; this community with low growth efficiency was dominated by Firmicutes (increased to 50.9%) and other anaerobic taxa. Human-associated bacteria, including the obligately anaerobic Bacteroides, were detected at high concentrations in soil throughout decomposition, up to 198 d postmortem. Our results revealed the pattern of functional and compositional succession

  1. Microbial Signatures of Cadaver Gravesoil During Decomposition.

    Science.gov (United States)

    Finley, Sheree J; Pechal, Jennifer L; Benbow, M Eric; Robertson, B K; Javan, Gulnaz T

    2016-04-01

    Genomic studies have estimated there are approximately 10(3)-10(6) bacterial species per gram of soil. The microbial species found in soil associated with decomposing human remains (gravesoil) have been investigated and recognized as potential molecular determinants for estimates of time since death. The nascent era of high-throughput amplicon sequencing of the conserved 16S ribosomal RNA (rRNA) gene region of gravesoil microbes is allowing research to expand beyond more subjective empirical methods used in forensic microbiology. The goal of the present study was to evaluate microbial communities and identify taxonomic signatures associated with the gravesoil human cadavers. Using 16S rRNA gene amplicon-based sequencing, soil microbial communities were surveyed from 18 cadavers placed on the surface or buried that were allowed to decompose over a range of decomposition time periods (3-303 days). Surface soil microbial communities showed a decreasing trend in taxon richness, diversity, and evenness over decomposition, while buried cadaver-soil microbial communities demonstrated increasing taxon richness, consistent diversity, and decreasing evenness. The results show that ubiquitous Proteobacteria was confirmed as the most abundant phylum in all gravesoil samples. Surface cadaver-soil communities demonstrated a decrease in Acidobacteria and an increase in Firmicutes relative abundance over decomposition, while buried soil communities were consistent in their community composition throughout decomposition. Better understanding of microbial community structure and its shifts over time may be important for advancing general knowledge of decomposition soil ecology and its potential use during forensic investigations.

  2. A comparative study of vascular injection fluids in fresh-frozen and embalmed human cadaver forearms

    NARCIS (Netherlands)

    Doomernik, D.E.; Kruse, R.R.; Reijnen, M.M.; Kozicz, T.; Kooloos, J.G.M.

    2016-01-01

    Over the years, various vascular injection products have been developed to facilitate anatomical dissections. This study aimed to compare the most commonly used vascular injection products in fresh-frozen and formalin-embalmed cadaver specimens. An overview of the properties, advantages and

  3. Yield Strength Testing in Human Cadaver Nasal Septal Cartilage and L-Strut Constructs.

    Science.gov (United States)

    Liu, Yuan F; Messinger, Kelton; Inman, Jared C

    2017-01-01

    To our knowledge, yield strength testing in human nasal septal cartilage has not been reported to date. An understanding of the basic mechanics of the nasal septum may help surgeons decide how much of an L-strut to preserve and how much grafting is needed. To determine the factors correlated with yield strength of the cartilaginous nasal septum and to explore the association between L-strut width and thickness in determining yield strength. In an anatomy laboratory, yield strength of rectangular pieces of fresh cadaver nasal septal cartilage was measured, and regression was performed to identify the factors correlated with yield strength. To measure yield strength in L-shaped models, 4 bonded paper L-struts models were constructed for every possible combination of the width and thickness, for a total of 240 models. Mathematical modeling using the resultant data with trend lines and surface fitting was performed to quantify the associations among L-strut width, thickness, and yield strength. The study dates were November 1, 2015, to April 1, 2016. The factors correlated with nasal cartilage yield strength and the associations among L-strut width, thickness, and yield strength in L-shaped models. Among 95 cartilage pieces from 12 human cadavers (mean [SD] age, 67.7 [12.6] years) and 240 constructed L-strut models, L-strut thickness was the only factor correlated with nasal septal cartilage yield strength (coefficient for thickness, 5.54; 95% CI, 4.08-7.00; P cadaver nasal septal cartilage, L-strut thickness was significantly associated with yield strength. In a bonded paper L-strut model, L-strut thickness had a more important role in determining yield strength than L-strut width. Surgeons should consider the thickness of potential L-struts when determining the amount of cartilaginous septum to harvest and graft. NA.

  4. An evaluation of soil chemistry in human cadaver decomposition islands: Potential for estimating postmortem interval (PMI).

    Science.gov (United States)

    Fancher, J P; Aitkenhead-Peterson, J A; Farris, T; Mix, K; Schwab, A P; Wescott, D J; Hamilton, M D

    2017-10-01

    Soil samples from the Forensic Anthropology Research Facility (FARF) at Texas State University, San Marcos, TX, were analyzed for multiple soil characteristics from cadaver decomposition islands to a depth of 5centimeters (cm) from 63 human decomposition sites, as well as depths up to 15cm in a subset of 11 of the cadaver decomposition islands plus control soils. Postmortem interval (PMI) of the cadaver decomposition islands ranged from 6 to 1752 days. Some soil chemistry, including nitrate-N (NO 3 -N), ammonium-N (NH 4 -N), and dissolved inorganic carbon (DIC), peaked at early PMI values and their concentrations at 0-5cm returned to near control values over time likely due to translocation down the soil profile. Other soil chemistry, including dissolved organic carbon (DOC), dissolved organic nitrogen (DON), orthophosphate-P (PO 4 -P), sodium (Na + ), and potassium (K + ), remained higher than the control soil up to a PMI of 1752days postmortem. The body mass index (BMI) of the cadaver appeared to have some effect on the cadaver decomposition island chemistry. To estimate PMI using soil chemistry, backward, stepwise multiple regression analysis was used with PMI as the dependent variable and soil chemistry, body mass index (BMI) and physical soil characteristics such as saturated hydraulic conductivity as independent variables. Measures of soil parameters derived from predator and microbial mediated decomposition of human remains shows promise in estimating PMI to within 365days for a period up to nearly five years. This persistent change in soil chemistry extends the ability to estimate PMI beyond the traditionally utilized methods of entomology and taphonomy in support of medical-legal investigations, humanitarian recovery efforts, and criminal and civil cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Cat dissection and human cadaver prosection versus sculpting human structures from clay: A comparison of alternate approaches to human anatomy laboratory education

    Science.gov (United States)

    Waters, John R.

    Dissection and vivisection are traditional approaches to biology laboratory education. In the case of human anatomy teaching laboratories, there is a long tradition of using human and animal cadaver specimens in the classroom. In a review of the literature comparing traditional dissection and vivisection lessons to alternative lessons designed to reduce the time spent dissecting or the numbers of animals used, we conclude that it is difficult to come to any conclusion regarding the efficacy of different approaches. An analysis of the literature is confounded because many studies have very low statistical power or other methodological weaknesses, and investigators rely on a wide variety of testing instruments to measure an equally varied number of course objectives. Additional well designed studies are necessary before educators can reach any informed conclusions about the efficacy of traditional versus alternative approaches to laboratory education. In our experiments, we compared a traditional cat dissection based undergraduate human anatomy lesson to an alternative where students sculpted human muscles onto plastic human skeletons. Students in the alternative treatment performed significantly better than their peers in the traditional treatment when answering both lower and higher order human anatomy questions. In a subsequent experiment with a similar design, we concluded that the superior performance of the students in the alternative treatment on anatomy exams was likely due to the similarity between the human anatomy representation studied in lab, and the human anatomy questions asked on the exams. When the anatomy questions were presented in the context of a cat specimen, students in the traditional cat dissection treatment outperformed their peers in the alternative treatment. In a final experiment where student performance on a human anatomy exam was compared between a traditional prosected human cadaver treatment and the alternative clay sculpting

  6. A comparative study of vascular injection fluids in fresh-frozen and embalmed human cadaver forearms.

    Science.gov (United States)

    Doomernik, D E; Kruse, R R; Reijnen, M M P J; Kozicz, T L; Kooloos, J G M

    2016-10-01

    Over the years, various vascular injection products have been developed to facilitate anatomical dissections. This study aimed to compare the most commonly used vascular injection products in fresh-frozen and formalin-embalmed cadaver specimens. An overview of the properties, advantages and limitations of each substance was given, and a comparison of vascular infusion procedures in both preservation methods was made. A literature search was performed in order to identify the most commonly used vascular injection products. Acrylic paint, latex, gelatin, silicone, Araldite F and Batson's No. 17 were selected for the study. One fresh-frozen and one embalmed cadaver forearm were infused with each injection product according to a uniform protocol. The curing time, skin- and subcutaneous tissue penetration, degree of filling of the arterial tree, extravasations, consistency of the injected vessels during dissection, and the costs of each injection fluid were noted. There was a large variation between the injection fluids in processing- and curing time, colour intensity, flexibility, fragility, elasticity, strength, toxicity and costs. All fluids were suitable for infusion. The penetration of injection fluid into the skin and subcutaneous tissue was significantly better in fresh-frozen specimens (P = 0.002 and P = 0.009, respectively), with significantly smaller branches casted (P = 0.004). Vascular infusion of fresh-frozen cadaver specimens results in a significantly better filled coloured arterial tree, enabling more detail to be achieved and smaller branches casted. The biomechanical properties of fresh-frozen soft tissues are less affected compared with formalin fixation. All the injection fluids studied are suitable for vascular infusion, but their different properties ensure that certain products and procedures are more suitable for specific study purposes. © 2016 Anatomical Society.

  7. Cadaver embalming fluid for surgical training courses: modified Larssen solution.

    Science.gov (United States)

    Bilge, Okan; Celik, Servet

    2017-11-01

    10% Formalin (F10)-fixed cadavers have disadvantages such as disturbing smell, mucosal irritation, discoloration and rigidity. We aimed to determine a suitable, simple and cost-effective embalming method that preserves color, texture, pliability and flexibility of the tissues for a long time without a disturbing smell and mucosal irritation. The embalmed cadavers were expected to be durable against environmental effects, utilizable for multiple and repetitive surgical trainings and instrumentations. Eight male (six intact, two autopsied bodies) and four female (three intact and one imported trunk) human cadavers were preserved with modified Larssen solution (MLS). Preserved bodies were kept in the deep freezers at -18/-20 °C. Bodies were allowed to thaw at room temperature 3 days prior to use. They were used in postgraduate hands-on courses for several medical disciplines. Each course lasted at least 1 day and during this period the bodies were stayed at room temperature. Assessments of 30 trainers and 252 trainees were collected during the courses. Additionally, the organoleptic characteristics of the fresh frozen (FF), preserved with MLS and F10-fixed cadavers were compared. The colors of muscles, fasciae, fatty tissue, nerves and vessels were evaluated and life-like tissues of MLS cadavers were impressive. There were no obvious or disturbing smell and sign of putrefaction of the MLS cadavers. MLS is a sustainable and relatively affordable soft cadaver embalming method. Its application is same as in other conventional methods and does not need new equipment. This article indicates the success of the MLS method in human cadavers.

  8. The Reliance on Unclaimed Cadavers for Anatomical Teaching by Medical Schools in Africa

    Science.gov (United States)

    Gangata, Hope; Ntaba, Phatheka; Akol, Princess; Louw, Graham

    2010-01-01

    The study of gross Anatomy through the use of cadaveric dissections in medical schools is an essential part of the comprehensive learning of human Anatomy, and unsurprisingly, 90% of the surveyed medical schools in Africa used cadaveric dissections. Donated cadavers now make up 80% of the total cadavers in North American medical schools and all…

  9. Short-term effects of hydrated lime and quicklime on the decay of human remains using pig cadavers as human body analogues: Laboratory experiments.

    Science.gov (United States)

    Schotsmans, Eline M J; Denton, John; Fletcher, Jonathan N; Janaway, Robert C; Wilson, Andrew S

    2014-05-01

    Contradictions and misconceptions regarding the effect of lime on the decay of human remains have demonstrated the need for more research into the effect of different types of lime on cadaver decomposition. This study follows previous research by the authors who have investigated the effect of lime on the decomposition of human remains in burial environments. A further three pig carcasses (Sus scrofa), used as human body analogues, were observed and monitored for 78 days without lime, with hydrated lime (Ca(OH)2) and with quicklime (CaO) in the taphonomy laboratory at the University of Bradford. The results showed that in the early stages of decay, the unlimed and hydrated lime cadavers follow a similar pattern of changes. In contrast, the application of quicklime instigated an initial acceleration of decay. Microbial investigation demonstrated that the presence of lime does not eliminate all aerobic bacteria. The experiment also suggested that lime functions as a sink, buffering the carbon dioxide evolution. This study complements the field observations. It has implications for the investigation of time since death of limed remains. Knowledge of the effects of lime on decomposition processes is of interest to forensic pathologists, archaeologists, humanitarian organisations and those concerned with disposal of animal carcasses or human remains in mass disasters. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Birth and death of human β-cells in pancreas from cadaver donors, autopsies, surgical specimens, and islets transplanted into mice

    Science.gov (United States)

    Caballero, Francisco; Siniakowicz, Karolina; Jennifer-Hollister-Lock; Duran, Luisa; Katsuta, Hitoshi; Yamada, Takatsugu; Lei, Ji; Deng, Shaoping; Westermark, Gunilla T.; Markmann, James; Bonner-Weir, Susan; Weir, Gordon C.

    2013-01-01

    There is great interest in the potential of the human endocrine pancreas for regeneration by β-cell replication or neogenesis. Our aim was to explore this potential in adult human pancreases and in both islet and exocrine tissue transplanted into mice. The design was to examine pancreases obtained from cadaver donors, autopsies and fresh surgical specimens and compare these findings with those obtained from islet and duct tissue grafted into the kidney. Islets and exocrine tissue were transplanted into normoglycemic ICR/SCID mice and studied 4 and 14 wk later. β-cell replication as assessed by double staining for insulin and Ki67 was 0.22 ± 0.03 % at 4 wk and 0.13 ± 0.03 % at 14 wk. In contrast, no evidence of β-cell replication could be found in 11 cadaver donor and 10 autopsy pancreases. However, Ki67 staining of β-cells in frozen sections obtained at surgery was comparable to that found in transplanted islets. Evidence for neogenesis in transplanted pancreatic exocrine tissue was supported by finding β-cells within the duct epithelium, and the presence of cells double stained for insulin and cytokeratin 19 (CK19). However, β-cells within the ducts never constituted more than 1% of the CK19 positive cells. With confocal microscopy, 7 of 12 examined cells expressed both markers, consistent with a neogeneic process. Mice with grafts containing islet or exocrine tissue were treated with various combinations exendin-4, gastrin and epidermal growth factor; none increased β-cell replication or stimulated neogenesis. In summary, human β-cells replicate at a low level in islets transplanted into mice and in surgical pancreatic frozen sections but rarely in cadaver donor or autopsy pancreases. The absence of β-cell replication in many adult cadaver or autopsy pancreases could, in part, be an artifact of the postmortem state. Thus, it appears that adult human β-cells maintain a low level of turnover through replication and neogenesis. PMID:23321263

  11. Birth and death of human β-cells in pancreases from cadaver donors, autopsies, surgical specimens, and islets transplanted into mice.

    Science.gov (United States)

    Caballero, Francisco; Siniakowicz, Karolina; Hollister-Lock, Jennifer; Duran, Luisa; Katsuta, Hitoshi; Yamada, Takatsugu; Lei, Ji; Deng, Shaoping; Westermark, Gunilla T; Markmann, James; Bonner-Weir, Susan; Weir, Gordon C

    2014-02-01

    There is great interest in the potential of the human endocrine pancreas for regeneration by β-cell replication or neogenesis. Our aim was to explore this potential in adult human pancreases and in both islet and exocrine tissue transplanted into mice. The design was to examine pancreases obtained from cadaver donors, autopsies, and fresh surgical specimens and compare these findings with those obtained from islet and duct tissue grafted into the kidney. Islets and exocrine tissue were transplanted into normoglycemic ICR-SCID mice and studied 4 and 14 weeks later. β-Cell replication, as assessed by double staining for insulin and Ki67, was 0.22 ± 0.03% at 4 weeks and 0.13 ± 0.03% at 14 weeks. In contrast, no evidence of β-cell replication could be found in 11 cadaver donor and 10 autopsy pancreases. However, Ki67 staining of β-cells in frozen sections obtained at surgery was comparable to that found in transplanted islets. Evidence for neogenesis in transplanted pancreatic exocrine tissue was supported by finding β-cells within the duct epithelium and the presence of cells double stained for insulin and cytokeratin 19 (CK19). However, β-cells within the ducts never constituted more than 1% of the CK19-positive cells. With confocal microscopy, 7 of 12 examined cells expressed both markers, consistent with a neogeneic process. Mice with grafts containing islet or exocrine tissue were treated with various combinations of exendin-4, gastrin, and epidermal growth factor; none increased β-cell replication or stimulated neogenesis. In summary, human β-cells replicate at a low level in islets transplanted into mice and in surgical pancreatic frozen sections, but rarely in cadaver donor or autopsy pancreases. The absence of β-cell replication in many adult cadaver or autopsy pancreases could, in part, be an artifact of the postmortem state. Thus, it appears that adult human β-cells maintain a low level of turnover through replication and neogenesis.

  12. A new substitute for formalin: Application to embalming cadavers.

    Science.gov (United States)

    Haizuka, Yoshinori; Nagase, Miki; Takashino, Satoshi; Kobayashi, Yasushi; Fujikura, Yoshihisa; Matsumura, George

    2018-01-01

    The development of formalin-free fixatives is an urgent issue in gross anatomy because of the health hazard and the tissue-hardening actions of formalin. We recently identified the fixative, antimicrobial, and preservative effects of N-vinyl-2-pyrrolidone (NVP), a precursor of the water-soluble macromolecular polymer polyvinylpyrrolidone, in animal experiments. The aim of the present study is to investigate whether NVP solution can be used as an alternative to formalin in human cadaveric dissection. Twelve donated cadavers were infused with NVP via the femoral and common carotid arteries using a peristaltic pump. Experienced teaching staff members in our department dissected the cadavers and examined their macroanatomical properties. The NVP-embalmed corpses showed no sign of decomposition or fungal growth. The bodies remained soft and flexible. Notably, the shoulder, elbow, wrist, phalangeal, hip, knee, cervical spine, and temporomandibular joints were highly mobile, almost equivalent to those of living individuals. The range of motion of most joints was greater in the NVP-fixed than formalin-fixed cadavers. Under the dermis, the subcutaneous fat was markedly reduced and the connective tissues were transparent, so the ligaments, cutaneous nerves, and veins were easily discernible. The abdominal wall and the visceral organs remained pliable and elastic, resembling those of fresh cadavers. The lungs, liver, and gastrointestinal tract were moveable in the thoracic and abdominal cavities and were readily isolated. NVP can be used successfully as a fixative and preservative solution for human cadavers; furthermore, NVP-embalmed bodies could be valuable for learning clinical skills and for training, and for developing innovative medical devices. Clin. Anat. 31:90-98, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  14. Effects of human hair on trans-cranial focused ultrasound efficacy in an ex-vivo cadaver model

    Science.gov (United States)

    Hananel, Arik; Snell, John W.; Kassell, Neal F.; Eames, Matthew D. C.

    2012-11-01

    Current practice before a trans-cranial MR guided Focused ultrasound procedure is shaving the patient head on treatment day. Here we present an initial attempt to evaluate the feasibility of trans-cranial FUS, in an unshaved, ex-vivo cadaver skull. We have sonicated using 220kHz and 710kHz head transducers, a cadaver skull filled with tissue mimicking phantom and covered with a wig made of human hair to evaluate feasibility of acoustic energy transfer in a full size model. Heating at focal point was measured using MR proton resonance shift thermometry. Results showed negligible effect of hair in 220kHz, and an 18% drop in temperature elevation when using 710kHz.

  15. Human cadaver retina model for retinal heating during corneal surgery with a femtosecond laser

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Yun, Jin; Zhao, Tianzhuo; Yan, Ying; Kurtz, Ron M.; Juhasz, Tibor

    2014-02-01

    Femtosecond lasers are widely used in everyday clinical procedures to perform minimally invasive corneal refractive surgery. The intralase femtosecond laser (AMO Corp. Santa Ana, CA) is a common example of such a laser. In the present study a numerical simulation was developed to quantify the temperature rise in the retina during femtosecond intracorneal surgery. Also, ex-vivo retinal heating due to laser irradiation was measured with an infrared thermal camera (Fluke Corp. Everett, WA) as a validation of the simulation. A computer simulation was developed using Comsol Multiphysics to calculate the temperature rise in the cadaver retina during femtosecond laser corneal surgery. The simulation showed a temperature rise of less than 0.3 degrees for realistic pulse energies for the various repetition rates. Human cadaver retinas were irradiated with a 150 kHz Intralase femtosecond laser and the temperature rise was measured withan infrared thermal camera. Thermal camera measurements are in agreement with the simulation. During routine femtosecond laser corneal surgery with normal clinical parameters, the temperature rise is well beneath the threshold for retina damage. The simulation predictions are in agreement with thermal measurements providing a level of experimental validation.

  16. "Detached Concern" of Medical Students in a Cadaver Dissection Course: A Phenomenological Study

    Science.gov (United States)

    Tseng, Wei-Ting; Lin, Ya-Ping

    2016-01-01

    The cadaver dissection course remains a time-honored tradition in medical education, partly because of its importance in cultivating professional attitudes in students. This study aims to investigate students' attitudes--specifically characterized as "detached concern"--in a cadaver dissection course. An interpretative phenomenological…

  17. ORIGINAL ARTICLE: A New Embalming Fluid for Preserving Cadavers

    Directory of Open Access Journals (Sweden)

    P.E. Natekar

    2012-07-01

    Full Text Available Background: Dissection laboratory is the only place where the three dimensional structure of the human body is reinforced by visual, auditory and tactile pathways. Cadavers are main teaching tools in Anatomy and are handled by the staff and students routinely. Very often the cadavers enbalmed by various chemicals are not effective in inhibiting growth of fungi, bacteria, maggots etc. To date limited studies have been carried out to overcome this problem hence this study was undertaken to find out safe and effective enbalming fluid. Aims and Objectives: The main object of the present study is to provide a composition of body-preservation fluid which is effective in preventing decomposition of cadavers, maintaining a desired life-like appearance of the body which is non hazardous for dissection and environmentally safe. It was observed that chemical composition of the embalming fluid was very effective in prevention of growth of bacteria, fungus and also decay and discoloration. Results: This study was carried out in the department of Anatomy, Goa Medical College, Bambolim Goa (India from the year 2006 to 2011. Total 100 cadavers were embalmed with the following composition of the embalming fluid. It was observed that the solution in tanks where intact bodies were preserved was clear without any fungus form a period of 5 years whereas the dissected cadavers were kept separately also containing 10 percent formalin showed minimal growth of fungus after 12 months and the solution was replaced after 12 months. Conclusions: In our present study the tank containing undissected cadavers has not shown any growth of fungus for a period of 5 years. Routine dissected parts showed fungal growth only after 12 months, whereupon the scum was removed and the tank solution replaced. The arterial fluid was red in colour and could be differentiated from cavity fluid. The cadavers were free from growth of fungus and maggots during their entire first MBBS course. Not

  18. Formulated arthropod cadavers for pest suppression

    OpenAIRE

    2001-01-01

    Pesticidal and/or antimicrobial biological agent-infected arthropod cadavers are formulated by applying a coating agent once on the surface of the cadaver which either (a) prevents the cadavers from sticking together and/or rupturing or (b) acts as an adhesive for a powder or granule applied to the cadaver to prevent sticking and rupturing. The formulated cadavers maintain or improve infectivity, reproducibility, and survivability. The formulated cadavers can be partially desiccated to improv...

  19. Safety of lumbar spine radiofrequency procedures in the presence of posterior pedicle screws: technical report of a cadaver study.

    Science.gov (United States)

    Gazelka, Halena M; Welch, Tasha L; Nassr, Ahmad; Lamer, Tim J

    2015-05-01

    To determine whether the thermal energy associated with lumbar spine radiofrequency neurotomy (RFN) performed near titanium and stainless steel pedicle screws is conducted to the pedicle screws or adjacent tissues, or both, thus introducing potential for thermal damage to those tissues. Cadaver study. Cadaver laboratory equipped with fluoroscopy, surgical spine implements, and radiofrequency generator. No live human subject; a fresh frozen (and thawed) cadaver torso was used for the study. Titanium and stainless steel pedicle screws were placed in the lumbar spine of a fresh frozen cadaver torso with real-time fluoroscopic guidance. Conventional RFN cannula placement was performed at the level of pedicle screws and a control (nonsurgically altered) lumbar level. Neurotomy was performed with conventional radiofrequency lesioning parameters. Temperatures were recorded at multiple sites through thermistor probes. Direct contact of the radiofrequency cannula with the pedicle screws during conventional RFN produced a substantial increase in temperature in the surrounding soft tissues. A small increase in temperature occurred at the same sites at the control level. Titanium and stainless steel pedicle screws are capable of sustaining large increases in temperature when the radiofrequency probe comes in contact with the screw. These results are suggestive that pedicle screws could serve as a possible source of tissue heating and thermal injury during RFN. Wiley Periodicals, Inc.

  20. Use of cadaver models in point-of-care emergency ultrasound education for diagnostic applications.

    Science.gov (United States)

    Zaia, Brita E; Briese, Beau; Williams, Sarah R; Gharahbaghian, Laleh

    2012-10-01

    As the use of bedside emergency ultrasound (US) increases, so does the need for effective US education. To determine 1) what pathology can be reliably simulated and identified by US in human cadavers, and 2) feasibility of using cadavers to improve the comfort of emergency medicine (EM) residents with specific US applications. This descriptive, cross-sectional survey study assessed utility of cadaver simulation to train EM residents in diagnostic US. First, the following pathologies were simulated in a cadaver: orbital foreign body (FB), retrobulbar (RB) hematoma, bone fracture, joint effusion, and pleural effusion. Second, we assessed residents' change in comfort level with US after using this cadaver model. Residents were surveyed regarding their comfort level with various US applications. After brief didactic sessions on the study's US applications, participants attempted to identify the simulated pathology using US. A post-lab survey assessed for change in comfort level after the training. Orbital FB, RB hematoma, bone fracture, joint effusion, and pleural effusion were readily modeled in a cadaver in ways typical of a live patient. Twenty-two residents completed the pre- and post-lab surveys. After training with cadavers, residents' comfort improved significantly for orbital FB and RB hematoma (mean increase 1.6, pcadavers helpful. Cadavers can simulate orbital FB, RB hematoma, bone fracture, joint effusion, and pleural effusion, and in our center improved the comfort of residents in identifying all but pleural effusion. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Point Organ Radiation Dose in Abdominal CT: Effect of Patient Off-Centering in an Experimental Human Cadaver Study.

    Science.gov (United States)

    Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K

    2017-08-01

    To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p 92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Single-port unilateral transaxillary totally endoscopic thyroidectomy: A survival animal and cadaver feasibility study

    Directory of Open Access Journals (Sweden)

    Henrique Neubarth Phillips

    2016-01-01

    Full Text Available Background: Single-port unilateral axillary thyroidectomy has great potential to become a valid alternative technique for thyroid surgery. We tested the technique in a study on live animals and cadavers to evaluate the feasibility and reproducibility of the procedure. Materials and Methods: Institutional review board (IRB approval was obtained in our university by the Council of Ethics for the study in surviving animals and cadavers. Subtotal thyroidectomy using unilateral axillary single port was performed in five dogs and five cadavers. Performing incision in the axillary fossa, a disposable single port was inserted. The dissection progressed for creating a subcutaneous tunnel to the subplatysmal region; after opening the platysma muscle and separation of the strap muscles, the thyroid gland was identified. After key anatomical landmarks were identified, the dissection was started at the upper pole towards the bottom, and to the isthmus. Specimens were extracted intact through the tunnel. Clinical and laboratorial observations of the experimental study in a 15-day follow-up and intraoperative data were documented. Results: All surgeries were performed in five animals which survived 15 days without postoperative complications. In the surgeries successfully performed in five cadavers, anatomical landmarks were recognised and intraoperative dissection of recurrent nerves and parathyroid glands was performed. Mean operative time was 64 min (46-85 min in animals and 123 min (110-140 min in cadavers, with a good cosmetic outcome since the incision was situated in the axillary fold. Conclusion: The technique of single-port axillary unilateral thyroidectomy was feasible and reproducible in the cadavers and animal survival study, suggesting the procedure as an alternative to minimally invasive surgery of the neck.

  3. Relative device stability of anterior versus axillary needle decompression for tension pneumothorax during casualty movement: Preliminary analysis of a human cadaver model.

    Science.gov (United States)

    Leatherman, Matthew L; Held, Jenny M; Fluke, Laura M; McEvoy, Christian S; Inaba, Kenji; Grabo, Daniel; Martin, Matthew J; Earley, Angela S; Ricca, Robert L; Polk, Travis M

    2017-07-01

    Tension pneumothorax (tPTX) remains a significant cause of potentially preventable death in military and civilian settings. The current prehospital standard of care for tPTX is immediate decompression with a 14-gauge 8-cm angiocatheter; however, failure rates may be as high as 17% to 60%. Alternative devices, such as 10-gauge angiocatheter, modified Veress needle, and laparoscopic trocar, have shown to be potentially more effective in animal models; however, little is known about the relative insertional safety or mechanical stability during casualty movement. Seven soft-embalmed cadavers were intubated and mechanically ventilated. Chest wall thickness was measured at the second intercostal space at the midclavicular line (2MCL) and the fifth intercostal space along the anterior axillary line (5AAL). CO2 insufflation created a PTX, and needle decompression was then performed with a randomized device. Insertional depth was measured between hub and skin before and after simulated casualty transport. Thoracoscopy was used to evaluate for intrapleural placement and/or injury during insertion and after movement. Cadaver demographics, device displacement, device dislodgment, and injuries were recorded. Three decompressions were performed at each site (2MCL/5AAL), totaling 12 events per cadaver. Eighty-four decompressions were performed. Average cadaver age was 59 years, and body mass index was 24 kg/m. The CWT varied between cadavers because of subcutaneous emphysema, but the average was 39 mm at the 2MCL and 31 mm at the 5AAL. Following movement, the 2MCL site was more likely to become dislodged than the 5AAL (67% vs. 17%, p = 0.001). Median displacement also differed between 2MCL and 5AAL (23 vs. 2 mm, p = 0.001). No significant differences were noted in dislodgement or displacement between devices. Five minor lung injuries were noted at the 5AAL position. Preliminary results from this human cadaver study suggest the 5AAL position is a more stable and reliable location

  4. Comparison of Expandable and Fixed Interbody Cages in a Human Cadaver Corpectomy Model: Fatigue Characteristics.

    Science.gov (United States)

    Pekmezci, Murat; Tang, Jessica A; Cheng, Liu; Modak, Ashin; McClellan, Robert T; Buckley, Jenni M; Ames, Christopher P

    2016-11-01

    In vitro cadaver biomechanics study. The goal of this study is to compare the in situ fatigue life of expandable versus fixed interbody cage designs. Expandable cages are becoming more popular, in large part, due to their versatility; however, subsidence and catastrophic failure remain a concern. This in vitro analysis investigates the fatigue life of expandable and fixed interbody cages in a single level human cadaver corpectomy model by evaluating modes of subsidence of expandable and fixed cages as well as change in stiffness of the constructs with cyclic loading. Nineteen specimens from 10 human thoracolumbar spines (T10-L2, L3-L5) were biomechanically evaluated after a single level corpectomy that was reconstructed with an expandable or fixed cage and anterior dual rod instrumentation. All specimens underwent 98 K cycles to simulate 3 months of postoperative weight bearing. In addition, a third group with hyperlordotic cages was used to simulate catastrophic failure that is observed in clinical practice. Three fixed and 2 expandable cages withstood the cyclic loading despite perfect sagittal and coronal plane fitting of the endcaps. The majority of the constructs settled in after initial subsidence. The catastrophic failures that were observed in clinical practice could not be reproduced with hyperlordotic cages. However, all cages in this group subsided, and 60% resulted in endplate fractures during deployment of the cage. Despite greater surface contact area, expandable cages have a trend for higher subsidence rates when compared with fixed cages. When there is edge loading as in the hyperlordotic cage scenario, there is a higher risk of subsidence and intraoperative fracture during deployment of expandable cages.

  5. Upper and Lower Limb Muscle Architecture of a 104 Year-Old Cadaver.

    Science.gov (United States)

    Ruggiero, Marissa; Cless, Daniel; Infantolino, Benjamin

    2016-01-01

    Muscle architecture is an important component to typical musculoskeletal models. Previous studies of human muscle architecture have focused on a single joint, two adjacent joints, or an entire limb. To date, no study has presented muscle architecture for the upper and lower limbs of a single cadaver. Additionally, muscle architectural parameters from elderly cadavers are lacking, making it difficult to accurately model elderly populations. Therefore, the purpose of this study was to present muscle architecture of the upper and lower limbs of a 104 year old female cadaver. The major muscles of the upper and lower limbs were removed and the musculotendon mass, tendon mass, musculotendon length, tendon length, pennation angle, optimal fascicle length, physiological cross-sectional area, and tendon cross-sectional area were determined for each muscle. Data from this complete cadaver are presented in table format. The data from this study can be used to construct a musculoskeletal model of a specific individual who was ambulatory, something which has not been possible to date. This should increase the accuracy of the model output as the model will be representing a specific individual, not a synthesis of measurements from multiple individuals. Additionally, an elderly individual can be modeled which will provide insight into muscle function as we age.

  6. Splenorenal shunt via magnetic compression technique: a feasibility study in canine and cadaver.

    Science.gov (United States)

    Xue, Fei; Li, Jianpeng; Lu, Jianwen; Zhu, Haoyang; Liu, Wenyan; Zhang, Hongke; Yang, Huan; Guo, Hongchang; Lv, Yi

    2016-12-01

    The concept of magnetic compression technique (MCT) has been accepted by surgeons to solve a variety of surgical problems. In this study, we attempted to explore the feasibility of a splenorenal shunt using MCT in canine and cadaver. The diameters of the splenic vein (SV), the left renal vein (LRV), and the vertical interval between them, were measured in computer tomography (CT) images obtained from 30 patients with portal hypertension and in 20 adult cadavers. The magnetic devices used for the splenorenal shunt were then manufactured based on the anatomic parameters measured above. The observation of the anatomical structure showed there were no special structural tissues or any important organs between SV and LRV. Then the magnetic compression splenorenal shunt procedure was performed in three dogs and five cadavers. Seven days later, the necrotic tissue between the two magnets was shed and the magnets were removed with the anchor wire. The feasibility of splenorenal shunt via MCT was successfully shown in both canine and cadaver, thus providing a theoretical support for future clinical application.

  7. Medical Students' Attitudinal Changes towards Cadaver Dissection ...

    African Journals Online (AJOL)

    Background: Recently, not only the medical school curriculum but also medical students' attitude towards cadaver-based learning of anatomy has changed. This investigation is therefore designed to analyse students' attitudes towards human cadaveric dissection before and after exposure to dissection. Methods: A ...

  8. Pulmonary Complications of Mustard Gas Exposure: A Study on Cadavers

    Directory of Open Access Journals (Sweden)

    Behnam Behnoush

    2011-04-01

    Full Text Available Sulfur mustard gas is one of the chemical warfare gases that roughly about 45000 soldiers continue to suffer long-lasting consequences of exposure during the Iran-Iraq war between 1980 and 1988. According to the common pulmonary lesions due to this gas exposure, we studied gross and microscopic pulmonary lesions in cadavers and also assessed the main causes of mortality caused by mustard gas exposure. A case-series study was performed on hospital record files of 100 cadavers that were exposed with documented sulfur mustard gas during the Iran-Iraq war from 1979 to 1988 and autopsied in legal medicine organization In Tehran between 2005 and 2007 and gross and microscopic pathological findings of autopsied organs such as hematological, pulmonary, hepatic, and renal changes were evaluated. All cases were male with the mean age of 43 years. The time interval between the gas exposure and death was almost 20years. The most frequent pulmonary complication was chronic bronchitis in 81% of autopsied cadavers. Other pulmonary findings were progressive pulmonary fibrosis (9%, pulmonary infections and tuberculosis (29%, malignant cellular infiltration (4%, and aspergilloma (1%. According to the chronic progressive lesions caused by mustard gas exposure such as pulmonary lesions and also its high mortality rate, suitable programming for protection of the gas exposed persons and prohibiting chemical warfare are recommended.

  9. Perception of Surgical Faculty on the Utility of Modified Thiel Embalmed Cadavers

    Directory of Open Access Journals (Sweden)

    Ashwini C Appaji

    2017-10-01

    Full Text Available Introduction: Surgical skills training on low and high fidelity simulators have been in practice for over a decade, but due to the high cost of virtual reality simulators it is beyond the reach of institutions and trainees. Among the simulators, high fidelity simulators such as a suitably prepared human anatomical specimen would give a real feel as if doing the procedure in the living. Hence, having soft, supple cadaver with organoleptic properties is an ideal situation for training by simulation and research. To facilitate the surgical skill training and research, chemical embalming was adopted with modifications of the Thiel method, for cadaver preservation. Aim: The aim of this study was to study the perception of the surgical faculty’s experience on the utility of modified Thiel embalmed cadavers for surgical procedures. Materials and Methods: In this cross-sectional study, a feedback was taken from practicing surgeons of broad and sub specialties such as general surgery, orthopedic surgery, neurosurgery, plastic surgery, pediatric surgery, ophthalmology, ENT, OBG, Transplant surgery (n=54. A 5 point Likert scale questionnaire was used with criteria of measurements like skin color, consistency, odour, differentiation of the layers, approach to the area, joint mobility and suitability for the procedure. Results: The scores ranged from 3.9 to 4.46/5. The participants expressed satisfaction on the cadaver quality on their utility for performance of surgical procedures. They expressed that, such embalmed cadavers would be excellent for learning purpose, surgical skills training in orthopedic procedures like arthroscopy. They felt the joint mobility was good, the consistency was soft and differentiation of layers was good. Some felt the tissues were fragile and would easily give away losing their strength. Conclusion: Thiel embalmed cadavers retain their organoleptic properties and hence facilitate surgical skills training. The thiel embalmed

  10. A cadaver study of mastoidectomy using an image-guided human-robot collaborative control system.

    Science.gov (United States)

    Yoo, Myung Hoon; Lee, Hwan Seo; Yang, Chan Joo; Lee, Seung Hwan; Lim, Hoon; Lee, Seongpung; Yi, Byung-Ju; Chung, Jong Woo

    2017-10-01

    Surgical precision would be better achieved with the development of an anatomical monitoring and controlling robot system than by traditional surgery techniques alone. We evaluated the feasibility of robot-assisted mastoidectomy in terms of duration, precision, and safety. Human cadaveric study. We developed a multi-degree-of-freedom robot system for a surgical drill with a balancing arm. The drill system is manipulated by the surgeon, the motion of the drill burr is monitored by the image-guided system, and the brake is controlled by the robotic system. The system also includes an alarm as well as the brake to help avoid unexpected damage to vital structures. Experimental mastoidectomy was performed in 11 temporal bones of six cadavers. Parameters including duration and safety were assessed, as well as intraoperative damage, which was judged via pre- and post-operative computed tomography. The duration of mastoidectomy in our study was comparable with that required for chronic otitis media patients. Although minor damage, such as dura exposure without tearing, was noted, no critical damage to the facial nerve or other important structures was observed. When the brake system was set to 1 mm from the facial nerve, the postoperative average bone thicknesses of the facial nerve was 1.39, 1.41, 1.22, 1.41, and 1.55 mm in the lateral, posterior pyramidal and anterior, lateral, and posterior mastoid portions, respectively. Mastoidectomy can be successfully performed using our robot-assisted system while maintaining a pre-set limit of 1 mm in most cases. This system may thus be useful for more inexperienced surgeons. NA.

  11. Effect of wrist and interphalangeal thumb movement on zone T2 flexor pollicis longus tendon tension in a human cadaver model.

    Science.gov (United States)

    Rappaport, Patricia O; Thoreson, Andrew R; Yang, Tai-Hua; Reisdorf, Ramona L; Rappaport, Stephen M; An, Kai-Nan; Amadio, Peter C

    2015-01-01

    Therapy after flexor pollicis longus (FPL) repair typically mimics finger flexor management, but this ignores anatomic and biomechanical features unique to the FPL. We measured FPL tendon tension in zone T2 to identify biomechanically appropriate exercises for mobilizing the FPL. Eight human cadaver hands were studied to identify motions that generated enough force to achieve FPL movement without exceeding hypothetical suture strength. With the carpometacarpal and metacarpophalangeal joints blocked, appropriate forces were produced for both passive interphalangeal (IP) motion with 30° wrist extension and simulated active IP flexion from 0° to 35° with the wrist in the neutral position. This work provides a biomechanical basis for safely and effectively mobilizing the zone T2 FPL tendon. Our cadaver study suggests that it is safe and effective to perform early passive and active exercise to an isolated IP joint. NA. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  12. Medical students' reactions to anatomic dissection and the phenomenon of cadaver naming.

    Science.gov (United States)

    Williams, Austin D; Greenwald, Emily E; Soricelli, Rhonda L; DePace, Dennis M

    2014-01-01

    The teaching of gross anatomy has, for centuries, relied on the dissection of human cadavers, and this formative experience is known to evoke strong emotional responses. The authors hypothesized that the phenomenon of cadaver naming is a coping mechanism used by medical students and that it correlates with other attitudes about dissection and body donation. The authors developed a 33-question electronic survey to which 1,156 medical students at 12 medical schools in the United States voluntarily responded (November 2011-March 2012). They also surveyed course directors from each institution regarding their curricula and their observations of students' coping mechanisms. The majority of students (574, 67.8%) named their cadaver. Students most commonly cited the cadaver's age as the reason they chose a particular name for the cadaver. A minority of the students who did not name the cadaver reported finding the practice of naming disrespectful. Almost all students indicated that they would have liked to know more about their donor, particularly his or her medical history. Finally, students who knew the birth name of the donor used it less frequently than predicted. The authors found that the practice of naming cadavers is extremely prevalent among medical students and that inventive naming serves as a beneficial coping mechanism. The authors suggest that developing a method of providing students with more information about their cadaver while protecting the anonymity of the donor and family would be useful. © 2012 American Association of Anatomists.

  13. Medical Students' Reactions to Anatomic Dissection and the Phenomenon of Cadaver Naming

    Science.gov (United States)

    Williams, Austin D.; Greenwald, Emily E.; Soricelli, Rhonda L.; DePace, Dennis M.

    2014-01-01

    The teaching of gross anatomy has, for centuries, relied on the dissection of human cadavers, and this formative experience is known to evoke strong emotional responses. The authors hypothesized that the phenomenon of cadaver naming is a coping mechanism used by medical students and that it correlates with other attitudes about dissection and body…

  14. Death, cadavers and post-mortem biomedical research: a point of view from a Christian community.

    Science.gov (United States)

    Charlier, Philippe; Joly, Alain; Champagnat, Julie; Brun, Luc; de la Grandmaison, Geoffroy Lorin; Hervé, Christian

    2013-12-01

    Facing modern developments of medicine and biomedical researches, religious communities are a strong source of ethics principles and orientations. Human dignity does not disappear after life, in a context of biomedical research on cadavers. Moral, political, social and scientific aspects of research on human cadavers (mainly autopsies) have been widely discussed in biomedical publications, whereas the religious ones (which could be predominant for some) have rarely been analyzed and presented. This article will present the results of a survey carried out a French Benedictine Abbey (relative to death, cadaver's status and biomedical research) and subsequent Christian background according to canonic texts and practical cases from anthropological, historical, archeological and biomedical origin.

  15. [Cadavers and mummies as therapeutic means].

    Science.gov (United States)

    Massart, D; Sohawon, S; Noordally, O

    2010-01-01

    Sickness befallen onto him, man found that plant and animal derivatives invigorated him. Thereafter, he found a therapeutic benefit in using man as a means of self cure and especially, dead man from violent death. The foam of the skull of cadaver was an excellent antiepileptic as well as blood coming out from a freshly decapitated man. By applying on diseased parts of his body, so as to get rid of inflammation or infection, cadaver's hands were used against tumors of all kinds. Dead human skin were processed into belts and used therein for helping delivery of parturition women. The mummy must be blackish, foul smelling and hard. Those who were whitish, odorless and powder-like, were unfit for use. Mummy powder applied to the nose would stop nose bleeding. Ambroise Paré (1510-1590) was an adversary of those practices.

  16. Cadaver Thanatomicrobiome Signatures: The Ubiquitous Nature of Clostridium Species in Human Decomposition

    Directory of Open Access Journals (Sweden)

    Gulnaz T. Javan

    2017-10-01

    Full Text Available Human thanatomicrobiome studies have established that an abundant number of putrefactive bacteria within internal organs of decaying bodies are obligate anaerobes, Clostridium spp. These microorganisms have been implicated as etiological agents in potentially life-threatening infections; notwithstanding, the scale and trajectory of these microbes after death have not been elucidated. We performed phylogenetic surveys of thanatomicrobiome signatures of cadavers’ internal organs to compare the microbial diversity between the 16S rRNA gene V4 hypervariable region and V3-4 conjoined regions from livers and spleens of 45 cadavers undergoing forensic microbiological studies. Phylogenetic analyses of 16S rRNA gene sequences revealed that the V4 region had a significantly higher mean Chao1 richness within the total microbiome data. Permutational multivariate analysis of variance statistical tests, based on unweighted UniFrac distances, demonstrated that taxa compositions were significantly different between V4 and V3-4 hypervariable regions (p < 0.001. Of note, we present the first study, using the largest cohort of criminal cases to date, that two hypervariable regions show discriminatory power for human postmortem microbial diversity. In conclusion, here we propose the impact of hypervariable region selection for the 16S rRNA gene in differentiating thanatomicrobiomic profiles to provide empirical data to explain a unique concept, the Postmortem Clostridium Effect.

  17. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  18. A New Electromagnetic Navigation System for Pedicle Screws Placement: A Human Cadaver Study at the Lumbar Spine.

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    Full Text Available Technical developments for improving the safety and accuracy of pedicle screw placement play an increasingly important role in spine surgery. In addition to the standard techniques of free-hand placement and fluoroscopic navigation, the rate of complications is reduced by 3D fluoroscopy, cone-beam CT, intraoperative CT/MRI, and various other navigation techniques. Another important aspect that should be emphasized is the reduction of intraoperative radiation exposure for personnel and patient. The aim of this study was to investigate the accuracy of a new navigation system for the spine based on an electromagnetic field.Twenty pedicle screws were placed in the lumbar spine of human cadavers using EMF navigation. Navigation was based on data from a preoperative thin-slice CT scan. The cadavers were positioned on a special field generator and the system was matched using a patient tracker on the spinous process. Navigation was conducted using especially developed instruments that can be tracked in the electromagnetic field. Another thin-slice CT scan was made postoperatively to assess the result. The evaluation included the position of the screws in the direction of trajectory and any injury to the surrounding cortical bone. The results were classified in 5 groups: grade 1: ideal screw position in the center of the pedicle with no cortical bone injury; grade 2: acceptable screw position, cortical bone injury with cortical penetration ≤ 2 mm; grade 3: cortical bone injury with cortical penetration 2,1-4 mm, grad 4: cortical bone injury with cortical penetration 4,1-6 mm, grade 5: cortical bone injury with cortical penetration >6 mm.The initial evaluation of the system showed good accuracy for the lumbar spine (65% grade 1, 20% grade 2, 15% grade 3, 0% grade 4, 0% grade 5. A comparison of the initial results with other navigation techniques in literature (CT navigation, 2D fluoroscopic navigation shows that the accuracy of this system is

  19. Four Forensic Entomology Case Studies: Records and Behavioral Observations on Seldom Reported Cadaver Fauna With Notes on Relevant Previous Occurrences and Ecology.

    Science.gov (United States)

    Lindgren, Natalie K; Sisson, Melissa S; Archambeault, Alan D; Rahlwes, Brent C; Willett, James R; Bucheli, Sibyl R

    2015-03-01

    A yearlong survey of insect taxa associated with human decomposition was conducted at the Southeast Texas Applied Forensic Science (STAFS) facility located in the Center for Biological Field Studies of Sam Houston State University in Huntsville, TX. During this study, four insect-cadaver interactions were observed that represent previously poorly documented yet forensically significant interactions: Syrphidae maggots colonized a corpse in an aquatic situation; Psychodidae adults mated and oviposited on an algal film that was present on a corpse that had been recently removed from water; several Panorpidae were the first insects to feed upon a freshly placed corpse in the autumn; and a noctuid caterpillar was found chewing and ingesting dried human skin. Baseline knowledge of insect-cadaver interactions is the foundation of forensic entomology, and unique observations have the potential to expand our understanding of decomposition ecology. © The Author 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  20. Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:: A Human Cadaver Study.

    Science.gov (United States)

    Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K

    2016-05-01

    The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Helicopter thermal imaging for detecting insect infested cadavers.

    Science.gov (United States)

    Amendt, Jens; Rodner, Sandra; Schuch, Claus-Peter; Sprenger, Heinz; Weidlich, Lars; Reckel, Frank

    2017-09-01

    One of the most common techniques applied for searching living and even dead persons is the FLIR (Forward Looking Infrared) system fixed on an aircraft like e.g. a helicopter, visualizing the thermal patterns emitted from objects in the long-infrared spectrum. However, as body temperature cools down to ambient values within approximately 24h after death, it is common sense that searching for deceased persons can be just applied the first day post-mortem. We postulated that the insect larval masses on a decomposing body generate a heat which can be considerably higher than ambient temperatures for a period of several weeks and that such heat signatures might be used for locating insect infested human remains. We examined the thermal history of two 70 and 90kg heavy pig cadavers for 21days in May and June 2014 in Germany. Adult and immature insects on the carcasses were sampled daily. Temperatures were measured on and inside the cadavers, in selected maggot masses and at the surroundings. Thermal imaging from a helicopter using the FLIR system was performed at three different altitudes up to 1500ft. during seven day-flights and one night-flight. Insect colonization was dominated by blow flies (Diptera: Calliphoridae) which occurred almost immediately after placement of the cadavers. Larvae were noted first on day 2 and infestation of both cadavers was enormous with several thousand larvae each. After day 14 a first wave of post-feeding larvae left the carcasses for pupation. Body temperature of both cadavers ranged between 15°C and 35°C during the first two weeks of the experiment, while body surface temperatures peaked at about 45°C. Maggot masses temperatures reached values up to almost 25°C above ambient temperature. Detection of both cadavers by thermal imaging was possible on seven of the eight helicopter flights until day 21. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  2. Intrathecal volume changes in lumbar spinal canal stenosis following extension and flexion: An experimental cadaver study.

    Science.gov (United States)

    Teske, Wolfram; Schwert, Martin; Zirke, Sonja; von Schulze Pellengahr, Christoph; Wiese, Matthias; Lahner, Matthias

    2015-01-01

    The spinal canal stenosis is a common disease in elderly. The thecal sac narrowing is considered as the anatomical cause for the disease. There is evidence that the anatomical proportions of the lumbar spinal canal are influenced by postural changes. The liquor volume shift during these postural changes is a valuable parameter to estimate the dynamic qualities of this disease. The aim of this human cadaver study was the determination of intrathecal fluid volume changes during the lumbar flexion and the extension. A special measuring device was designed and built for the study to investigate this issue under controlled conditions. The measuring apparatus fixed the lumbar spine firmly and allowed only flexion and extension. The dural sac was closed water tight. The in vitro changes of the intrathecal volumes during the motion cycle were determined according to the principle of communicating vessels. Thirteen human cadaver spines from the Institute of Anatomy were examined in a test setting with a continuous adjustment of motion. The diagnosis of the lumbar spinal stenosis was confirmed by a positive computer tomography prior testing. The volume changes during flexion and extension cycles were measured stepwise in a 2 degree distance between 18° flexion and 18° extension. Three complete series of measurements were performed for each cadaver. Two specimens were excluded because of fluid leaks from further investigation. The flexion of the lumbar spine resulted in an intrathecal volume increase. The maximum volume effects were seen in the early flexion positions of 2° and 4°. The spine reclination resulted in a volume reduction. The maximum extension effect was seen between 14° and 16°. According to our results, remarkable volume effects were seen in the early movements of the lumbar spine especially for the flexion. The results support the concept of the spinal stenosis as a dynamic disease and allow a better understanding of the pathophysiology of this

  3. Fish as aquatic “sniffer dogs”: Olfactory-mediated behaviors and conditioning of common carps to cadaver odors

    Directory of Open Access Journals (Sweden)

    Brian Wade Jamandre

    2015-12-01

    Full Text Available Even with the aide of modern technology, the search for cadaver or human remains underwater is still assisted by sniffer dogs mainly because of their superior sense of olfaction. However, dogs rely on volatile organic compounds in the air and that this may constraint their ability when searching for submerged cadavers. On the other hand, it has long been recognized that fishes use olfaction to sample odors from their surroundings to accomplish a task and are capable of acquiring new skills through training or conditioning. Despite decades of experimental and observational studies of the olfactory sensitivities of fishes, its potential application to forensic sciences has never been truly explored. In this pioneering research, we explore the possibility of using fish olfaction in detecting cadaver odors (porcine origin, using common carps Cyprinus carpio as model species in a series of experiments under laboratory conditions. We first observed the innate behavior of carps towards cadaver odors. Afterwards, the carps were trained in two-choice chamber experimental tanks by appetitive olfactory conditioning and odor masking methods. We also experimented on the effects of cadaver odors by early exposure using eggs and larval impregnation techniques, and observing the behaviors when they develop to early juveniles. In general, we found out that common carps are naturally repelled to cadaver odors. However using our devised conditioning protocol, results show that the conditioned carps were able to learn to be attracted to cadaver odors despite their innate aversion. The development of fish for cadaver detection is a simple but innovative idea and that it may present a cost-effective and reliable solution for the shortcomings of the existing methods in underwater cadaver search. We anticipate that this research will open up a variety of different studies in pursuit of developing fishes as biosensors and its application to forensic sciences.

  4. A study on preparation of cross sectional anatomy specimen of cadaver

    International Nuclear Information System (INIS)

    Im, C. K.; Choi, B. I.; Park, J. H.; Chang, K. H.; Yeon, K. M.; Han, M. C.; Kim, C. W.

    1984-01-01

    With the advent of cross sectional image of CT, ultrasound and magnetic resonance, the need for knowledge of cross sectional anatomy is stranger than ever. To meet this need, preparation of cross sectional anatomy specimen using cadaver is indispensable, not only because it tis the real cut surface anatomy but also because overt limitations of radiographic image in both contrast and special resolution. Authors prepared cross sectional anatomy specimen using a male cadaver, comprising photographs and slides of the 60 cross cut slices from the head to the pelvis. After photography, each slices was embedded using transparent resin allowing permanent preservation of specimen without altering its original architecture. Author's unique method of preparation is presented and 4 representative specimens are illustrated comparing cadaver's CT image, cross cut surface photography, and photography of resin embedded slice of the same cut surface.

  5. Human cadaver multipotent stromal/stem cells isolated from arteries stored in liquid nitrogen for 5 years

    Science.gov (United States)

    2014-01-01

    Introduction Regenerative medicine challenges researchers to find noncontroversial, safe and abundant stem cell sources. In this context, harvesting from asystolic donors could represent an innovative and unlimited reservoir of different stem cells. In this study, cadaveric vascular tissues were established as an alternative source of human cadaver mesenchymal stromal/stem cells (hC-MSCs). We reported the successful cell isolation from postmortem arterial segments stored in a tissue-banking facility for at least 5 years. Methods After thawing, hC-MSCs were isolated with a high efficiency (12 × 106) and characterized with flow cytometry, immunofluorescence, molecular and ultrastructural approaches. Results In early passages, hC-MSCs were clonogenic, highly proliferative and expressed mesenchymal (CD44, CD73, CD90, CD105, HLA-G), stemness (Stro-1, Oct-4, Notch-1), pericyte (CD146, PDGFR-β, NG2) and neuronal (Nestin) markers; hematopoietic and vascular markers were negative. These cells had colony and spheroid-forming abilities, multipotency for their potential to differentiate in multiple mesengenic lineages and immunosuppressive activity to counteract proliferation of phytohemagglutinin-stimulated blood mononuclear cells. Conclusions The efficient procurement of stem cells from cadaveric sources, as postmortem vascular tissues, demonstrates that such cells can survive to prolonged ischemic insult, anoxia, freezing and dehydration injuries, thus paving the way for a scientific revolution where cadaver stromal/stem cells could effectively treat patients demanding cell therapies. PMID:24429026

  6. Anatomic Assessment of Variations in Kambin's Triangle: A Surgical and Cadaver Study.

    Science.gov (United States)

    Ozer, Ali Fahir; Suzer, Tuncer; Can, Halil; Falsafi, Mani; Aydin, Murat; Sasani, Mehdi; Oktenoglu, Tunc

    2017-04-01

    The relationship of exiting root and Kambin's triangle is discussed in this article. Transforaminal endoscopic surgery as the gold standard of less invasive lumbar disc surgeries is performed through Kambin's triangle. Existing root damage is one of the most important complication for this type of surgery. Anatomic variations in Kambin's triangle may be the main reason for nerve root damage during endoscopic lumbar disc surgery. Kambin's triangle was investigated with surgical views and cadaver studies. Thirty-four patients with far lateral disc herniation were treated with an extraforaminal approach under the microscope. On the other hand, 48 Kambin's triangles were dissected on 8 cadavers. Three main types of triangle were identified, and patients were grouped according to these 3 types of the triangle. Only 6 of the 34 patients had type 3 triangles, which is the wide classical triangle described by Kambin; however, 17 patients had type 2, with a narrow space in the triangle, and 11 patients had type 1, with no space inside the triangle. Cadaver results were similar; only 10 of the 48 specimens had the type 3 classical triangle, whereas 23 specimens had type 2, and 15 specimens had type 1 triangles. Our results disclosed narrowed or no space in 82.4% of the patients and 79.2% of the cadavers. We observed that a wide and safe room of the triangle may not be exist in some patients. Therefore, more care must be taken during endoscopic lumbar disc surgery to avoid nerve damage. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. The Omental Pedicle Flap in Dogs Revised and Refined: A Cadaver Study.

    Science.gov (United States)

    Doom, Marjan; Cornillie, Pieter; Simoens, Paul; Huyghe, Stephanie; de Rooster, Hilde

    2016-08-01

    To expand current knowledge on the canine omental vasculature and refine the existing lengthening technique of the canine omentum. Ex vivo study. Canine cadavers (n=20). In 10 canine cadavers the omental arteries were mapped using intravascular latex injection and these results were used to create an omental pedicle flap based on the splenic artery in 10 additional cadavers. The operating range of the flap was recorded with particular attention to the main regions of interest for omental transposition in dogs (axillary and inguinal regions). The superficial and deep omental leaves were each predominantly supplied by a left and a right marginal omental artery that anastomosed near the caudal omental border into a superficial and a deep omental arch, respectively. Anastomoses between arteries of the superficial and the deep omental leaves were weak and inconsistent, except for 1 anastomosis that was found in 8 of 10 dogs. By transposing the intact omentum, the right axilla could be reached in 3 dogs, both axillae in 1 dog, and both groins in all cadavers. In all cases, the omental pedicle reached to and beyond the axillary and inguinal regions. By unfolding the pedicle leaves, the width of the pedicle tip could be doubled. When lengthening the omentum is necessary to reach extra-abdominal structures, the omental pedicle flap based on the splenic artery appears to preserve the omental vascular supply. These observations warrant further clinical trials to evaluate this new omtental flap technique in vivo. © Copyright 2016 by The American College of Veterinary Surgeons.

  8. Measurement of the tendon of the biceps brachii after tenotomy: study on cadavers

    Directory of Open Access Journals (Sweden)

    Anderson Cunha Machado

    2015-08-01

    Full Text Available ABSTRACTOBJECTIVE: To evaluate the influence of elbow and forearm range of motion on the distal excursion of the long head of the biceps (LHB. METHODS: The distal excursion of the LHB after tenotomy of the shoulders of eight cadavers was ascertained by measuring the distance between a point marked out on the LHB, 3 cm from the anterolateral border of the acromion, and its position at different degrees of elbow flexion, using a digital pachymeter. The measurements at elbow flexion of 135°, 90°, 45° and 0° were noted: these angles were established using a goniometer. The measurements were made with the forearm in neutral, supination and pronation positions. RESULTS: Differences between the mean measurements of the distal excursion of the LHB (total sample were observed between the degrees of elbow flexion ( p< 0.01. However, no statistical differences were observed between the different forearm positions, between the sides, genders and ages of the cadavers studied. CONCLUSION: Progressive extension of the elbow caused progressive distal excursion of the LHB, but without interference in the forearm position, gender, side or age of the cadavers studied.

  9. Deoxycholic Acid and the Marginal Mandibular Nerve: A Cadaver Study.

    Science.gov (United States)

    Blandford, Alexander D; Ansari, Waseem; Young, Jason M; Maley, Bruce; Plesec, Thomas P; Hwang, Catherine J; Perry, Julian D

    2018-06-04

    One of the rare but serious complications observed with deoxycholic acid administration is damage to the marginal mandibular nerve. In this study, we evaluated if deoxycholic acid directly induces histologic damage to fresh cadaveric marginal mandibular nerve. A segment of marginal mandibular nerve was harvested from 12 hemifaces of 6 fresh cadavers. The nerve specimen was exposed to either 0.9% sterile saline for 24 h, deoxycholic acid (10 mg/ml) for 20 min, or deoxycholic acid (10 mg/ml) for 24 h. The nerve specimens were then fixed in glutaraldehyde for a minimum of 24 h. Toluidine blue stained sections were evaluated for stain intensity using light microscopy and color deconvolution image analysis. Supraplatysmal fat was harvested as a positive control and exposed to the same treatments as the marginal mandibular nerve specimens, then evaluated using transmission electron microscopy. Toluidine blue staining was less in the marginal mandibular nerve exposed to deoxycholic acid when compared to saline. The specimen exposed to deoxycholic acid for 24 h showed less toluidine blue staining than that of the nerve exposed to deoxycholic acid for 20 min. Transmission electron microscopy of submental fat exposed to deoxycholic acid revealed disruption of adipocyte cell membrane integrity and loss of cellular organelles when compared to specimens only exposed to saline. Deoxycholic acid (10 mg/ml) damages the marginal mandibular nerve myelin sheath in fresh human cadaver specimens. Direct deoxycholic acid neurotoxicity may cause marginal mandibular nerve injury clinically. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO System: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Guoxin Fan

    Full Text Available Percutaneous transforaminal endoscopic discectomy (PTED usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence.This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO system in puncture reduction of PTED.Cadaver study.Comparative groups.HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A. Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B. On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C.At L4/L5 level, there was significant difference in puncture times between Group A and Group B (P0.05. There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05.Small-sample preclinical study.HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127.

  11. A Cross-sectional Morphometric Study of Thyroid Glands in Cadavers

    Directory of Open Access Journals (Sweden)

    Shrish Patil

    2017-10-01

    Full Text Available Introduction: Thyroid gland is an organ with a highly variable morphology. Despite several studies having been done to assess its measurements, a consensus has not been arrived at as to what constitutes a ‘normal’ thyroid. Aim: To determine the dimensions of the normal thyroid gland obtained from cadavers of South Indian region and to derive the mean and standard deviations of the measurements of the gland in the given population, thus contributing to the existing data. We also aimed to study three common but not constant components of the thyroid gland, namely Pyramidal Lobe (PL, Tubercle of Zukerkandl (TZ and Levator Glandulae Thyroideae (LGT. Materials and Methods: The study was conducted on thyroid glands obtained from cadavers of South Indian region. Institutional ethics committee approval was obtained. Sixty thyroid glands were obtained from cadavers received for either routine dissection or autopsies. The thyroid glands were studied after adequate exposure and fixing in formalin. Dimensions were measured using Vernier calipers. Specimens with anomalies like absent isthmus etc were excluded from the study. Statistical analysis was done using the MedCalc Version 17.0 software. Results: The average dimensions of the lobes were: height 3.83 cm, width 2.62 cm, and thickness 2.69 cm. The average dimensions of the isthmus were: height 1.38 cm, width 1.36 cm and thickness 1.29 cm. The average dimensions of the pyramidal lobe were: height 2.03 cm, width at the base 1.91 cm and thickness 1.16 cm. Pyramidal lobe was present in 60% of cases. Levator glandulae thyroideae was observable in three cases (5%. Significant correlation was found between the dimensions of right and left lobes and regression equations were calculated. Conclusion: The dimensions of the thyroid gland are very variable. Knowledge of the wide ranging variations and measurements will be of help to surgeons and radiologists in correct interpretation, diagnosis and treatment of

  12. 9 CFR 381.90 - Cadavers.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Cadavers. 381.90 Section 381.90 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY... § 381.90 Cadavers. Carcasses of poultry showing evidence of having died from causes other than slaughter...

  13. Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study.

    Science.gov (United States)

    Wagner, Franca; Wimmer, Wilhelm; Leidolt, Lars; Vischer, Mattheus; Weder, Stefan; Wiest, Roland; Mantokoudis, Georgios; Caversaccio, Marco D

    2015-01-01

    Cochlear implants (CIs) are standard treatment for postlingually deafened individuals and prelingually deafened children. This human cadaver study evaluated diagnostic usefulness, image quality and artifacts in 1.5T and 3T magnetic resonance (MR) brain scans after CI with a removable magnet. Three criteria (diagnostic usefulness, image quality, artifacts) were assessed at 1.5T and 3T in five cadaver heads with CI. The brain magnetic resonance scans were performed with and without the magnet in situ. The criteria were analyzed by two blinded neuroradiologists, with focus on image distortion and limitation of the diagnostic value of the acquired MR images. MR images with the magnet in situ were all compromised by artifacts caused by the CI. After removal of the magnet, MR scans showed an unequivocal artifact reduction with significant improvement of the image quality and diagnostic usefulness, both at 1.5T and 3T. Visibility of the brain stem, cerebellopontine angle, and parieto-occipital lobe ipsilateral to the CI increased significantly after magnet removal. The results indicate the possible advantages for 1.5T and 3T MR scanning of the brain in CI carriers with removable magnets. Our findings support use of CIs with removable magnets, especially in patients with chronic intracranial pathologies.

  14. Measurement of electric intensity distribution inside a human cadaver cochlea for multichannel cochlear implants; Multichannel jinko naiji no tame no hito no tekishutsu kagyunai ni okeru denkai kyodo bunpu no sokutei

    Energy Technology Data Exchange (ETDEWEB)

    Miyoshi, S.; Ifukube, T.; Matsushima, J. [Hokkaido University, Sapporo (Japan)

    1998-03-01

    We have proposed a Tripolar Electrode Stimulation Method (TESM) which may succeed in narrowing the stimulation region and continuously moving the stimulation site for cochlear implants. The TESM stimulates the auditory nerve array through lymph liquid using the 3 adjacent electrodes which are selected among the electrodes of an electrode array. The currents from the two electrodes on both sides are emitted and a central electrode receives them. The current received by the central electrode is made equal to the sum of the currents emitted from the electrodes on both sides. In this paper, the electric intensity profiles produced by the TESM and the monopolar stimulation were measured in a human cadaver cochlea and in a saline solution. As a result, in the TESM, the electric intensity profile produced in the human cadaver cochlea was about the same as that in the saline solution In monopolar stimulation, the electric intensity profile was broader than that of TESM in a human cadaver cochlea. 9 refs., 14 figs.

  15. The Dimensions of the Orbital Cavity Based on High-Resolution Computed Tomography of Human Cadavers

    DEFF Research Database (Denmark)

    Felding, Ulrik Ascanius; Bloch, Sune Land; Buchwald, Christian von

    2016-01-01

    for surface area. To authors' knowledge, this study is the first to have measured the entire surface area of the orbital cavity.The volume and surface area of the orbital cavity were estimated in computed tomography scans of 11 human cadavers using unbiased stereological sampling techniques. The mean (± SD......) total volume and total surface area of the orbital cavities was 24.27 ± 3.88 cm and 32.47 ± 2.96 cm, respectively. There was no significant difference in volume (P = 0.315) or surface area (P = 0.566) between the 2 orbital cavities.The stereological technique proved to be a robust and unbiased method...... that may be used as a gold standard for comparison with automated computer software. Future imaging studies in blow-out fracture patients may be based on individual and relative calculation involving both herniated volume and fractured surface area in relation to the total volume and surface area...

  16. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

    Science.gov (United States)

    Fan, Guoxin; Guan, Xiaofei; Sun, Qi; Hu, Annan; Zhu, Yanjie; Gu, Guangfei; Zhang, Hailong; He, Shisheng

    2015-01-01

    Percutaneous transforaminal endoscopic discectomy (PTED) usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence. This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO) system in puncture reduction of PTED. Cadaver study. Comparative groups. HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A). Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B). On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C). At L4/L5 level, there was significant difference in puncture times between Group A and Group B (PHELLO system reduced 39%-45% radiation dosage when comparing Group A and Group B, but there was no significant difference in radiation exposure between Group A and Group C whatever at L4/L5 level or L5/S1 level (P>0.05). There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05). Small-sample preclinical study. HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127).

  17. Navigation of Pedicle Screws in the Thoracic Spine with a New Electromagnetic Navigation System: A Human Cadaver Study

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    2015-01-01

    Full Text Available Introduction. Posterior stabilization of the spine is a standard procedure in spinal surgery. In addition to the standard techniques, several new techniques have been developed. The objective of this cadaveric study was to examine the accuracy of a new electromagnetic navigation system for instrumentation of pedicle screws in the spine. Material and Method. Forty-eight pedicle screws were inserted in the thoracic spine of human cadavers using EMF navigation and instruments developed especially for electromagnetic navigation. The screw position was assessed postoperatively by a CT scan. Results. The screws were classified into 3 groups: grade 1 = ideal position; grade 2 = cortical penetration <2 mm; grade 3 = cortical penetration ≥2 mm. The initial evaluation of the system showed satisfied positioning for the thoracic spine; 37 of 48 screws (77.1%, 95% confidence interval [62.7%, 88%] were classified as group 1 or 2. Discussion. The screw placement was satisfactory. The initial results show that there is room for improvement with some changes needed. The ease of use and short setup times should be pointed out. Instrumentation is achieved without restricting the operator’s mobility during navigation. Conclusion. The results indicate a good placement technique for pedicle screws. Big advantages are the easy handling of the system.

  18. Treatment of middle ear ventilation disorders: sheep as animal model for stenting the human Eustachian tube--a cadaver study.

    Directory of Open Access Journals (Sweden)

    Felicitas Miller

    Full Text Available Eustachian tube disorders can lead to chronic otitis media with consecutive conductive hearing loss. To improve treatment and to develop new types of implants such as stents, an adequate experimental animal model is required. As the middle ear of sheep is known to be comparable to the human middle ear, the dimensions of the Eustachian tube in two strains of sheep were investigated. The Eustachian tube and middle ear of half heads of heathland and blackface sheep were filled with silicone rubber, blended with barium sulfate to induce X-ray visibility. Images were taken by digital volume tomography. The tubes were segmented, and a three-dimensional model of every Eustachian tube was generated. The lengths, diameters and shapes were determined. Additionally, the feasibility of endoscopic stent implantation and fixation was tested in cadaver experiments. The length of the tube between ostium pharyngeum and the isthmus and the diameters were comparable to published values for the human tube. The tube was easily accessible through the nose, and then stents could be implanted and fixed at the isthmus. The sheep appears to be a promising model for testing new stent treatments for middle ear ventilation disorders.

  19. Insect cadaver applications: pros and cons

    Science.gov (United States)

    Application of entomopathogenic nematodes (EPNs) formulated as insect cadavers has become an alternative to aqueous application for the control of agricultural pests. In this approach, the infected insect host cadaver is applied directly to the target site and pest suppression is achieved by the inf...

  20. Subfracture insult to the human cadaver patellofemoral joint produces occult injury.

    Science.gov (United States)

    Atkinson, P J; Haut, R C

    1995-11-01

    The current criterion used by the automotive industry for injury to the lower extremity is based on visible bone fracture. Studies suggest, however, that chronic joint degeneration may occur after subfracture impact loads on the knee. We hypothesized that subfracture loading of the patellofemoral joint could result in previously undocumented microtrauma in areas of high contact pressure. In the current study, seven patellofemoral joints from human cadavers were subjected to impact with successively greater energy until visible fracture was noted. Transverse and comminuted fractures of the patella were noted at 6.7 kN of load. Approximately 45% of the impact energy then was delivered to the contralateral joint. Subfracture loads of 5.2 kN resulted in no gross bone fracture in five of seven specimens. Histological examination of the patellae horizontal split fracture in the subchondral bone, at the tidemark, or at the interface of calcified cartilage and subchondral bone. The trauma appeared predominantly on the lateral facet, adjacent to or directly beneath preexisting fibrillation of the articular surface. Surface fibrillation was noted in histological sections of control patellae (not subjected to impact loading), but occult damages were not observed. Although the mechanism of this occult trauma is unknown, similar damage has been shown to occur from direct shear loading. As these microcracks can potentiate a disease process in the joint, this study may suggest that the current criterion for injury, based on bone fracture alone, is not sufficiently conservative.

  1. Fresh frozen cadaver workshops for advanced vascular surgical training.

    Science.gov (United States)

    Jansen, Shirley; Cowie, Margaret; Linehan, John; Hamdorf, Jeffery M

    2014-11-01

    Reduction in working hours, streamlined training schemes and increasing use of endovascular techniques has meant a reduction in operative experience for newer vascular surgical trainees, especially those exposures which are not routinely performed such as thoracoabdominal, thoracotomy and retroperitoneal aortic, for example. This paper describes an Advanced Anatomy of Exposure course which was designed and convened at the Clinical Training & Evaluation Centre in Western Australia and uses fresh frozen cadavers. Feedback was obtained from the participants who attended over three courses by questionnaire. Feedback was strongly positive for the course meeting both its learning outcomes and personal learning objectives, and in addition, making a significant contribution to specialty skills. Most participants thought the fresh frozen cadaveric model significantly improved the learning objectives for training. The fresh frozen cadaver is an excellent teaching model highly representative of the living open surgical scenario where advanced trainees and newly qualified consultants can improve their operative confidence and consequently patient safety in vascular surgery. An efficient fresh frozen cadaver teaching programme can benefit many health professionals simultaneously maximizing the use of donated human tissue. © 2013 Royal Australasian College of Surgeons.

  2. Intraosseous vascular access through the anterior mandible--a cadaver model pilot study.

    Directory of Open Access Journals (Sweden)

    Christin Goldschalt

    Full Text Available BACKGROUND: Several insertion sites have been described for intraosseous puncture in cases of emergencies when a conventional vascular access cannot be established. This pilot study has been designed to evaluate the feasibility of the mandibular bone for the use of an intraosseous vascular access in a cadaver model. METHODOLOGY/PRINCIPAL FINDINGS: 17 dentistry and 16 medical students participating in a voluntary course received a short introduction into the method and subsequently used the battery powered EZ-IO system with a 15 mm cannula for a puncture of the anterior mandible in 33 cadavers. The time needed to perform each procedure was evaluated. India ink was injected into the accesses and during the anatomy course cadavers were dissected to retrace the success or failure of the puncture. Dental students needed 25.5±18.9(mean±standard deviations and medical students 33±20.4 s for the procedure (p = 0.18. Floor of mouth extravasation occurred in both groups in 3 cases. Success rates were 82 and 75% (p = 0.93. CONCLUSIONS/SIGNIFICANCE: Despite floor of mouth extravasation of injected fluid into a mandibular intraosseous access might severely complicate this procedure, the anterior mandible may be helpful as an alternative to other intraosseous and intravenous insertion sites when these are not available in medical emergencies.

  3. Near-Infrared Confocal Laser Reflectance Cytoarchitectural Imaging of the Substantia Nigra and Cerebellum in the Fresh Human Cadaver.

    Science.gov (United States)

    Cheyuo, Cletus; Grand, Walter; Balos, Lucia L

    2017-01-01

    Cytoarchitectural neuroimaging remains critical for diagnosis of many brain diseases. Fluorescent dye-enhanced, near-infrared confocal in situ cellular imaging of the brain has been reported. However, impermeability of the blood-brain barrier to most fluorescent dyes limits clinical utility of this modality. The differential degree of reflectance from brain tissue with unenhanced near-infrared imaging may represent an alternative technique for in situ cytoarchitectural neuroimaging. We assessed the utility of unenhanced near-infrared confocal laser reflectance imaging of the cytoarchitecture of the cerebellum and substantia nigra in 2 fresh human cadaver brains using a confocal near-infrared laser probe. Cellular images based on near-infrared differential reflectance were captured at depths of 20-180 μm from the brain surface. Parts of the cerebellum and substantia nigra imaged using the probe were subsequently excised and stained with hematoxylin and eosin for histologic correlation. Near-infrared reflectance imaging revealed the 3-layered cytoarchitecture of the cerebellum, with Purkinje cells appearing hyperreflectant. In the substantia nigra, neurons appeared hyporeflectant with hyperreflectant neuromelanin cytoplasmic inclusions. Cytoarchitecture of the cerebellum and substantia nigra revealed on near-infrared imaging closely correlated with the histology on hematoxylin-eosin staining. We showed that unenhanced near-infrared reflectance imaging of fresh human cadaver brain can reliably identify and distinguish neurons and detailed cytoarchitecture of the cerebellum and substantia nigra. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Toxic effects of formalin-treated cadaver on medical students, staff ...

    African Journals Online (AJOL)

    Background: Formaldehyde can be toxic, allergenic and carcinogenic. Evaporation of formaldehyde from formalin-treated cadavers in the anatomy dissection rooms can produce high exposure. This study was conducted to assess acute and chronic toxic effects of formalin-treated cadavers on medical students, staff ...

  5. A novel method to measure femoral component migration by computed tomography: a cadaver study.

    Science.gov (United States)

    Boettner, Friedrich; Sculco, Peter; Lipman, Joseph; Renner, Lisa; Faschingbauer, Martin

    2016-06-01

    Radiostereometric analysis (RSA) is the most accurate technique to measure implant migration. However, it requires special equipment, technical expertise and analysis software and has not gained wide acceptance. The current paper analyzes a novel method to measure implant migration utilizing widely available computer tomography (CT). Three uncemented total hip replacements were performed in three human cadavers and six tantalum beads were inserted into the femoral bone similar to RSA. Six different 28 mm heads (-3, 0, 2.5, 5.0, 7.5 and 10 mm) were added to simulate five reproducible translations (maximum total point migration) of the center of the head. Implant migration was measured in a 3-D analysis software (Geomagic Studio 7). Repeat manual reconstructions of the center of the head were performed by two investigators to determine repeatability and accuracy. The accuracy of measurements between the centers of two head sizes was 0.11 mm with a CI 95 % of 0.22 mm. The intra-observer repeatability was 0.13 mm (CI 95 % 0.25 mm). The interrater-reliability was 0.943. CT based measurement of head displacement in a cadaver model were highly accurate and reproducible.

  6. Primary fit of the Lord cementless total hip : a geometric study in cadavers

    NARCIS (Netherlands)

    Schimmel, J.W.; Huiskes, H.W.J.

    1988-01-01

    Two Lord prostheses, bilaterally implanted in cadavers, were sectioned. The contact areas between bone and prosthesis were studied and measured using a specially developed reproducible method. Primary fixation of the femoral components appeared to be based principally on wedging of the prosthetic

  7. [Identification and preservation of parathyroid glands in cadaver parts].

    Science.gov (United States)

    Melo, Catarina; Bernardes, António; Carvalho, Lina

    2013-01-01

    It is essential to know the thyroid gland morphology and its anatomical relations in the anterior compartment of the neck in order to minimize the rate of thyroid surgery morbidity, especially the lesion of parathyroid glands and laryngeal nerves. The aim of this study was the identification of parathyroid glands in cadaver parts and their histological confirmation. Twenty cadaver parts were used to simulate thyroidectomies. During dissection, the thyroid glands and eventual parathyroid glands were isolated and then submitted to histological study. Twenty cadaver parts (anterior cervical organs) were used for macroscopic dissection during which 48 fragments that corresponded to eventual parathyroid glands were isolated, 35 of which were effectively confirmed through histological observation to be parathyroid glands. The 20 cadaver parts were then divided into three groups according to the number of histologically confirmed parathyroid glands. In the first group, composed of 11 cases, all eventual parathyroid glands were confirmed. In the second group, composed of six cases, only some glands were confirmed. In the third group, composed of three cases, none of the possible glands were confirmed. In seven of the 20 isolated thyroid glands, eight parathyroid glands were identified during histological study: four subcapsular, three extra-capsular, one intra-thyroidal. There was no statistical relation in the dimensions of the parathyroid glands. The knowledge of the anatomy of the central visceral compartment of the neck and its most frequent variations reduces but doesn't eliminate thyroid surgery morbidity, especially parathyroid iatrogenic excision, difficulty which has been demonstrated during the dissection of cadaver parts.

  8. Pullout strength of bone-patellar tendon-bone allograft bone plugs: a comparison of cadaver tibia and rigid polyurethane foam.

    Science.gov (United States)

    Barber, F Alan

    2013-09-01

    To compare the load-to-failure pullout strength of bone-patellar tendon-bone (BPTB) allografts in human cadaver tibias and rigid polyurethane foam blocks. Twenty BPTB allografts were trimmed creating 25 mm × 10 mm × 10 mm tibial plugs. Ten-millimeter tunnels were drilled in 10 human cadaver tibias and 10 rigid polyurethane foam blocks. The BPTB anterior cruciate ligament allografts were inserted into these tunnels and secured with metal interference screws, with placement of 10 of each type in each material. After preloading (10 N), cyclic loading (500 cycles, 10 to 150 N at 200 mm/min) and load-to-failure testing (200 mm/min) were performed. The endpoints were ultimate failure load, cyclic loading elongation, and failure mode. No difference in ultimate failure load existed between grafts inserted into rigid polyurethane foam blocks (705 N) and those in cadaver tibias (669 N) (P = .69). The mean rigid polyurethane foam block elongation (0.211 mm) was less than that in tibial bone (0.470 mm) (P = .038), with a smaller standard deviation (0.07 mm for foam) than tibial bone (0.34 mm). All BPTB grafts successfully completed 500 cycles. The rigid polyurethane foam block showed less variation in test results than human cadaver tibias. Rigid polyurethane foam blocks provide an acceptable substitute for human cadaver bone tibia for biomechanical testing of BPTB allografts and offer near-equivalent results. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Review of forensically important entomological specimens collected from human cadavers in Malaysia (2005-2010).

    Science.gov (United States)

    Kavitha, Rajagopal; Nazni, Wasi Ahmad; Tan, Tian Chye; Lee, Han Lim; Azirun, Mohd Sofian

    2013-07-01

    Forensic entomological specimens collected from human decedents during crime scene investigations in Malaysia in the past 6 years (2005-2010) are reviewed. A total of 80 cases were recorded and 93 specimens were collected. From these specimens, 10 species of cyclorrphagic flies were identified, consisting of Chrysomya rufifacies (Macquart) -38 specimens (40.86%), Chrysomya megacephala (Fabricius) -36 specimens (38.70%), Chrysomya villeneuvi (Patton) -2 specimens (2.15%), Chrysomya nigripes (Aubertin) -2 specimens (2.15%), Chrysomya pinguis (Walker) -1 specimen (1.08%), Hermetia illucens (Linnaeus) -1 specimen (1.08%), Hemipyrellia liguriens (Wiedemann) -5 specimens (5.37%), Synthesiomyia nudiseta (Wulp) -1 specimen (1.08%), Megaselia scalaris (Loew)-1 specimen (1.08%) and Sarcophaga ruficornis (Fabricius) -4 specimens (4.30%). In two specimens (2.15%), the maggots were not identifiable. Ch. megacephala and Ch. rufifacies were the commonest species found in human decedents from three different ecological habitats. S. nudiseta is an uncommon species found only on human cadavers from indoors. A total of 75 cases (93.75%) had a single fly infestation and 5 cases (6.25%) had double fly infestation. In conclusion, although large numbers of fly species were found on human decedents, the predominant species are still those of Chrysomya. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  10. Construction of tomographic head model using sectioned photographic images of cadaver

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Lee, Jai Ki; Park, Jin Seo; Chung, Min Suk

    2004-01-01

    Tomographic models are currently the most complete, developed and realistic models of the human anatomy. They have been used to estimate organ doses for diagnostic radiation examination and radiotherapy treatment planning, and radiation protection. The quality of original anatomic images is a key factor to build a quality tomographic model. Computed tomography (CT) and magnetic resonance imaging (MRI) scan, from which most of current tomographic models are constructed, have their inherent shortcomings. In this study, a tomographic model of Korean adult male head was constructed by using serially sectioned photographs of cadaver. The cadaver was embedded, frozen, serially sectioned and photographed by high resolution digital camera at 0.2 mm interval. The contours of organs and tissues in photographs were segmented by several trained anatomists. The 120 segmented images of head at 2mm interval were converted into binary files and ported into Monte Carlo code to perform an example calculation of organ dose. Whole body tomographic model will be constructed by using the procedure developed in this study

  11. MORPHOMETRIC ANALYSIS OF CORPUS CALLOSUM- A STUDY IN CADAVER AND MRI

    Directory of Open Access Journals (Sweden)

    Ambili Puthanveetil

    2017-07-01

    Full Text Available BACKGROUND The Corpus Callosum (CC can best be seen in the mid-sagittal section of brain both in cadaver and MRI. The morphometric measurements of the same will be of use in neurosurgical procedures. Sexual dimorphism and the age-related changes in its measurements remained controversial. Till date, no studies have been done on corpus callosum in Kerala. MATERIALS AND METHODS Measurements of CC has been taken and studied in detail in 24 formalin fixed brains from the Department of Anatomy and 48 MR images from the Department of Radiology. The changes according to age and sex were analysed. RESULTS The mean length of CC in the cadaver was 7.24 cm, which was 3.38 cm posterior to frontal pole and 5.73 cm anterior to occipital pole. In MR images, the mean length was 7.10 in males and 6.76 in females. The difference we got was not statistically significant. The length increased with age. Thickness of genu and body decreased as the age advances, but the splenial thickness was found to be increasing with age. There was significant correlation between the thicknesses of various parts of CC. CONCLUSION The values were almost similar to those in the previous studies. Morphometrically, a significant gender difference was not identified in the present study. There were changes according to age both in males and females.

  12. Self-Reported Emergency Medicine Residency Applicant Attitudes Towards a Procedural Cadaver Laboratory Curriculum

    Directory of Open Access Journals (Sweden)

    Hoffman, Lance

    2008-08-01

    Full Text Available OBJECTIVE: Residency applicants consider a variety of factors when ranking emergency medicine (EM programs for their NRMP match list. A human cadaver emergency procedure lab curriculum is uncommon. We hypothesized that the presence this curriculum would positively impact the ranking of an EM residency program.METHODS: The EM residency at Nebraska Medical Center is an urban, university-based program with a PGY I-III format. Residency applicants during the interview for a position in the PGY I class of 2006 were surveyed by three weekly electronic mailings. The survey was distributed in March 2006 after the final NRMP match results were released. The survey explored learner preferences and methodological commonality of models of emergency procedural training, as well as the impact of a procedural cadaver lab curriculum on residency ranking. ANOVA of ranks was used to compare responses to ranking questions.RESULTS: Of the 73 potential subjects, 54 (74% completed the survey. Respondents ranked methods of procedural instruction from 1 (most preferred or most common technique to 4 (least preferred or least common technique. Response averages and 95% confidence intervals for the preferred means of learning a new procedure are as follows: textbook (3.69; 3.51-3.87, mannequin (2.83; 2.64-3.02, human cadaver (1.93; 1.72-2.14, and living patient (1.56; 1.33-1.79. Response averages for the commonality of means used to teach a new procedure are as follows: human cadaver (3.63; 3.46-3.80, mannequin (2.70; 2.50-2.90, living patient (2.09; 1.85-2.33, and textbook (1.57; 1.32-1.82. When asked if the University of Nebraska Medical Center residency ranked higher in the individual's match list because of its procedural cadaver lab, 14.8% strongly disagreed, 14.8% disagreed, 40.7% were neutral, 14.8% agreed, and 14.8% strongly agreed.CONCLUSION: We conclude that, although cadaveric procedural training is viewed by senior medical student learners as a desirable means

  13. Long-term effects of hydrated lime and quicklime on the decay of human remains using pig cadavers as human body analogues: Field experiments.

    Science.gov (United States)

    Schotsmans, Eline M J; Fletcher, Jonathan N; Denton, John; Janaway, Robert C; Wilson, Andrew S

    2014-05-01

    An increased number of police enquiries involving human remains buried with lime have demonstrated the need for more research into the effect of different types of lime on cadaver decomposition and its micro-environment. This study follows previous studies by the authors who have investigated the effects of lime on the decay of human remains in laboratory conditions and 6 months of field experiments. Six pig carcasses (Sus scrofa), used as human body analogues, were buried without lime with hydrated lime (Ca(OH)2) and quicklime (CaO) in shallow graves in sandy-loam soil in Belgium and recovered after 17 and 42 months of burial. Analysis of the soil, lime and carcasses included entomology, pH, moisture content, microbial activity, histology and lime carbonation. The results of this study demonstrate that despite conflicting evidence in the literature, the extent of decomposition is slowed down by burial with both hydrated lime and quicklime. The more advanced the decay process, the more similar the degree of liquefaction between the limed and unlimed remains. The end result for each mode of burial will ultimately result in skeletonisation. This study has implications for the investigation of clandestine burials, for a better understanding of archaeological plaster burials and potentially for the interpretation of mass graves and management of mass disasters by humanitarian organisation and DVI teams. Copyright © 2014. Published by Elsevier Ireland Ltd.

  14. Saturated salt solution method: a useful cadaver embalming for surgical skills training.

    Science.gov (United States)

    Hayashi, Shogo; Homma, Hiroshi; Naito, Munekazu; Oda, Jun; Nishiyama, Takahisa; Kawamoto, Atsuo; Kawata, Shinichi; Sato, Norio; Fukuhara, Tomomi; Taguchi, Hirokazu; Mashiko, Kazuki; Azuhata, Takeo; Ito, Masayuki; Kawai, Kentaro; Suzuki, Tomoya; Nishizawa, Yuji; Araki, Jun; Matsuno, Naoto; Shirai, Takayuki; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Fukui, Hidekimi; Ohseto, Kiyoshige; Yukioka, Tetsuo; Itoh, Masahiro

    2014-12-01

    This article evaluates the suitability of cadavers embalmed by the saturated salt solution (SSS) method for surgical skills training (SST). SST courses using cadavers have been performed to advance a surgeon's techniques without any risk to patients. One important factor for improving SST is the suitability of specimens, which depends on the embalming method. In addition, the infectious risk and cost involved in using cadavers are problems that need to be solved. Six cadavers were embalmed by 3 methods: formalin solution, Thiel solution (TS), and SSS methods. Bacterial and fungal culture tests and measurement of ranges of motion were conducted for each cadaver. Fourteen surgeons evaluated the 3 embalming methods and 9 SST instructors (7 trauma surgeons and 2 orthopedists) operated the cadavers by 21 procedures. In addition, ultrasonography, central venous catheterization, and incision with cauterization followed by autosuture stapling were performed in some cadavers. The SSS method had a sufficient antibiotic effect and produced cadavers with flexible joints and a high tissue quality suitable for SST. The surgeons evaluated the cadavers embalmed by the SSS method to be highly equal to those embalmed by the TS method. Ultrasound images were clear in the cadavers embalmed by both the methods. Central venous catheterization could be performed in a cadaver embalmed by the SSS method and then be affirmed by x-ray. Lungs and intestines could be incised with cauterization and autosuture stapling in the cadavers embalmed by TS and SSS methods. Cadavers embalmed by the SSS method are sufficiently useful for SST. This method is simple, carries a low infectious risk, and is relatively of low cost, enabling a wider use of cadavers for SST.

  15. A novel cadaver-based educational program in general surgery training.

    Science.gov (United States)

    Lewis, Catherine E; Peacock, Warwick J; Tillou, Areti; Hines, O Joe; Hiatt, Jonathan R

    2012-01-01

    To describe the development of a cadaver-based educational program and report our residents' assessment of the new program. An anatomy-based educational program was developed using fresh frozen cadavers to teach surgical anatomy and operative skills to general surgery (GS) trainees. Residents were asked to complete a voluntary, anonymous survey evaluating perceptions of the program (6 questions formulated on a 5-point Likert scale) and comparing cadaver sessions to other types of learning (4 rank order questions). Large university teaching hospital. Medical students, residents, and faculty members were participants in the cadaver programs. Only GS residents were asked to complete the survey. Since its implementation, 150 residents of all levels participated in 13 sessions. A total of 40 surveys were returned for a response rate of 89%. Overall, respondents held a positive view of the cadaver sessions and believed them to be useful for learning anatomy (94% agree or strongly agree), learning the steps of an operation (76% agree or strongly agree), and increasing confidence in doing an operation (53% agree or strongly agree). Trainees wanted to have more sessions (87% agree or strongly agree), and believed they would spend free time in the cadaver laboratory (58% agree or strongly agree). Compared with other learning modalities, cadaver sessions were ranked first for learning surgical anatomy, followed by textbooks, simulators, web sites, animate laboratories, and lectures. Respondents also ranked cadaver sessions first for increasing confidence in performing a procedure and for learning the steps of an operation. Cost of cadavers represented the major expense of the program. Fresh cadaver dissections represent a solution to the challenges of efficient, safe, and effective general surgery education. Residents have a positive attitude toward these teaching sessions and found them to be more effective than other learning modalities. Copyright © 2012 Association of

  16. Feasibility of using interstitial ultrasound for intradiscal thermal therapy: a study in human cadaver lumbar discs

    International Nuclear Information System (INIS)

    Nau, William H; Diederich, Chris J; Shu, Richard

    2005-01-01

    Application of heat in the spine using resistive wire heating devices is currently being used clinically for minimally invasive treatment of discogenic low back pain. In this study, interstitial ultrasound was evaluated for the potential to heat intradiscal tissue more precisely by directing energy towards the posterior annular wall while avoiding vertebral bodies. Two single-element directional applicator design configurations were tested: a 1.5 mm OD direct-coupled (DC) applicator which can be implanted directly within the disc, and a catheter-cooled (CC) applicator which is inserted in a 2.4 mm OD catheter with integrated water cooling and implanted within the disc. The transducers were sectored to produce 90 deg. spatial heating patterns for directional control. Both applicator configurations were evaluated in four human cadaver lumbar disc motion segments. Two heating protocols were employed in this study in which the temperature measured 5 mm away from the applicator was controlled to either T = 52 deg. C, or T > 70 deg. C for the treatment period. These temperatures (thermal doses) are representative of those required for thermal necrosis of in-growing nociceptor nerve fibres and disc cellularity alone, or with coagulation and restructuring of annular collagen in the high-temperature case. Steady-state temperature maps, and thermal doses (t 43 ) were used to assess the thermal treatments. Results from these studies demonstrated the capability of controlling temperature distributions within selected regions of the disc and annular wall using interstitial ultrasound, with minimal vertebral end-plate heating. While directional heating was demonstrated with both applicator designs, the CC configuration had greater directional heating capabilities and offered better temperature control than the DC configuration, particularly during the high-temperature protocol. Further, ultrasound energy was capable of penetrating within the highly attenuating disc tissue to

  17. Novel Application of Postmortem CT Angiography for Evaluation of the Intracranial Vascular Anatomy in Cadaver Heads.

    Science.gov (United States)

    van Eijk, Ruben P A; van der Zwan, Albert; Bleys, Ronald L A W; Regli, Luca; Esposito, Giuseppe

    2015-12-01

    Postmortem CT angiography is a common procedure used to visualize the entire human vasculature. For visualization of a specific organ's vascular anatomy, casting is the preferred method. Because of the permanent and damaging nature of casting, the organ cannot be further used as an experimental model after angiography. Therefore, there is a need for a minimally traumatic method to visualize organ-specific vascular anatomy. The purpose of this study was to develop and evaluate a contrast enhancement technique that is capable of visualizing the intracranial vascular anatomy while preserving the anatomic integrity in cadaver heads. Seven human heads were used in this study. Heads were prepared by cannulating the vertebral and internal carotid arteries. Contrast agent was injected as a mixture of tap water, polyethylene glycol 600, and an iodinated contrast agent. Postmortem imaging was executed on a 64-MDCT scanner. Primary image review and 3D reconstruction were performed on a CT workstation. Clear visualization of the major cerebral arteries and smaller intracranial branches was achieved. Adequate visualization was obtained for both the anterior and posterior intracranial circulation. The minimally traumatic angiography method preserved the vascular integrity of the cadaver heads. A novel application of postmortem CT angiography is presented here. The technique can be used for radiologic evaluation of the intracranial circulation in cadaver heads. After CT angiography, the specimen can be used for further experimental or laboratory testing and teaching purposes.

  18. Anatomical aspects of the gastrocnemius muscles: A study in 47 fresh cadavers.

    Science.gov (United States)

    Andjelkov, Katarina; Atanasijevic, Tatjana C; Popovic, Vesna M; Sforza, Marcos; Atkinson, Connor J; Soldatovic, Ivan

    2016-08-01

    This study offers objective dimensions of the gastrocnemius muscle and analyzes correlations between dimensional variables, with a view to providing guidance on the proportions of a healthy gastrocnemius muscle for both genders. This anatomical study was conducted at the Institute of Forensic Medicine Faculty of Medicine University of Belgrade, Serbia, from May until November 2014. We included 47 fresh cadavers (up to 12-h postmortem interval) both male and female. The inclusion criteria were absence of any trauma or degenerative findings in lower limbs, normally weighed, and age between 18 and 60 years. The exclusion criteria were significant difference in dimensions between legs and overweighed cadavers. After statistical analysis of gathered data, we were able to define the exact shape and average measures of the medial and lateral head of gastrocnemius muscle in male and female. Factors affecting muscle dimensions are also defined in this study. The method of dissection that we applied could be recommended for exploration of different anatomical structures of calf region. The reported dimensions and correlations are useful guide in planning cosmetic and reconstructive procedures with high accuracy. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Fabrication and characterization of scaffold from cadaver goat-lung tissue for skin tissue engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sweta K. [Department of Polymer and Process Engineering, Indian Institute of Technology, Roorkee (India); Dinda, Amit K. [Department of Pathology, All India Institute of Medical Sciences, New Delhi (India); Potdar, Pravin D. [Department of Molecular Medicine, Jaslok Hospital and Research Centre, Mumbai (India); Mishra, Narayan C., E-mail: mishrawise@gmail.com [Department of Polymer and Process Engineering, Indian Institute of Technology, Roorkee (India)

    2013-10-15

    The present study aims to fabricate scaffold from cadaver goat-lung tissue and evaluate it for skin tissue engineering applications. Decellularized goat-lung scaffold was fabricated by removing cells from cadaver goat-lung tissue enzymatically, to have cell-free 3D-architecture of natural extracellular matrix. DNA quantification assay and Hematoxylin and eosin staining confirmed the absence of cellular material in the decellularized lung-tissue. SEM analysis of decellularized scaffold shows the intrinsic porous structure of lung tissue with well-preserved pore-to-pore interconnectivity. FTIR analysis confirmed non-denaturation and well maintainance of collagenous protein structure of decellularized scaffold. MTT assay, SEM analysis and H and E staining of human skin-derived Mesenchymal Stem cell, seeded over the decellularized scaffold, confirms stem cell attachment, viability, biocompatibility and proliferation over the decellularized scaffold. Expression of Keratin18 gene, along with CD105, CD73 and CD44, by human skin-derived Mesenchymal Stem cells over decellularized scaffold signifies that the cells are viable, proliferating and migrating, and have maintained their critical cellular functions in the presence of scaffold. Thus, overall study proves the applicability of the goat-lung tissue derived decellularized scaffold for skin tissue engineering applications. - Highlights: • We successfully fabricated decellularized scaffold from cadaver goat-lung tissue. • Decellularized goat-lung scaffolds were found to be highly porous. • Skin derived MSC shows high cell viability and proliferation over the scaffold. • Phenotype of MSCs was well maintained over the scaffold. • The scaffold shows potential for applications in skin tissue engineering.

  20. Fabrication and characterization of scaffold from cadaver goat-lung tissue for skin tissue engineering applications

    International Nuclear Information System (INIS)

    Gupta, Sweta K.; Dinda, Amit K.; Potdar, Pravin D.; Mishra, Narayan C.

    2013-01-01

    The present study aims to fabricate scaffold from cadaver goat-lung tissue and evaluate it for skin tissue engineering applications. Decellularized goat-lung scaffold was fabricated by removing cells from cadaver goat-lung tissue enzymatically, to have cell-free 3D-architecture of natural extracellular matrix. DNA quantification assay and Hematoxylin and eosin staining confirmed the absence of cellular material in the decellularized lung-tissue. SEM analysis of decellularized scaffold shows the intrinsic porous structure of lung tissue with well-preserved pore-to-pore interconnectivity. FTIR analysis confirmed non-denaturation and well maintainance of collagenous protein structure of decellularized scaffold. MTT assay, SEM analysis and H and E staining of human skin-derived Mesenchymal Stem cell, seeded over the decellularized scaffold, confirms stem cell attachment, viability, biocompatibility and proliferation over the decellularized scaffold. Expression of Keratin18 gene, along with CD105, CD73 and CD44, by human skin-derived Mesenchymal Stem cells over decellularized scaffold signifies that the cells are viable, proliferating and migrating, and have maintained their critical cellular functions in the presence of scaffold. Thus, overall study proves the applicability of the goat-lung tissue derived decellularized scaffold for skin tissue engineering applications. - Highlights: • We successfully fabricated decellularized scaffold from cadaver goat-lung tissue. • Decellularized goat-lung scaffolds were found to be highly porous. • Skin derived MSC shows high cell viability and proliferation over the scaffold. • Phenotype of MSCs was well maintained over the scaffold. • The scaffold shows potential for applications in skin tissue engineering

  1. Study of the Artroscopic Anatomy of the Knee in Canine Cadavers Using 2.4 Mm Diameter Lens

    Directory of Open Access Journals (Sweden)

    Gabriel Oswaldo Alonso Cuéllar

    2013-05-01

    Full Text Available Mainly by a limited access to new techniques and technologies, veterinary medicine in developing countries, has been far behind from the human medicine. One of the causes is the limited access to technology and specific techniques. Moreover, it is clear that many new technologies have proven their benefits in the two disciplines, making necessary and almost mandatory their massive implementation in humans and animals. The possibility to use human elements for veterinary techniques would improve the technology access and veterinarians training, at lower costs. The purpose of this study is to verify the feasibility to perform a knee arthroscopy in dogs with small human joints arthroscopic lenses. Under protocols established in veterinary 12 knee arthroscopies were performed in canine cadaver, using a wrist and ankle arthroscope human of 2.4 mm in diameter and 30° of angulation. All the structures reported in the literature were possible to visualize using a 2.4 mm arthroscope. In this sense, it is possible to develop training activities and subsequent implementation of endoscopic techniques in canine femorotibiopatellar joint, using a lens of small joints of human medicine.

  2. Transvaginal Pelvic Floor Muscle Injection Technique: A Cadaver Study.

    Science.gov (United States)

    Gupta, Priyanka; Ehlert, Michael; Sirls, Larry T; Peters, Kenneth

    Women with pelvic floor dysfunction can have tender areas on vaginal examination, which can be treated with trigger-point injections. There are no publications to evaluate the accuracy of pelvic floor muscle injections. Trigger-point injections were performed on 2 fresh cadaveric pelvises using a curved nasal cannula guide and 7-in spinal needle. This was performed using our standard template of 2 sets of injections at the 1-, 3-, and 5-o'clock positions distally and proximally. The first pelvis was dissected to examine dye penetration. Based on these results, we modified our technique and repeated the injections on the second cadaver. We dissected the second pelvis and compared our findings. The 1-o'clock proximal and distal injections stained the obturator internus and externus near the insertion at the ischiopubic ramus. The 3-o'clock injections stained the midbody of the pubococcygeus and puborectalis. The distal 5-o'clock position was too deep and stained the fat of the ischiorectal space. The proximal 5-o'clock injection stained the area of the pudendal nerve. Our goal at the distal 5-o'clock position was to infuse the iliococcygeus muscle, so we shortened the needle depth from 2 to 1 cm beyond the cannula tip. In our second dissection, the distal 5-o'clock injection again stained only the fat of the ischiorectal space. This is the first study to characterize the distribution of pelvic floor muscle injections in a cadaver model and confirms the ability to deliver medications effectively to the pelvic floor muscles.

  3. Spread of Injectate Around Hip Articular Sensory Branches of the Femoral Nerve in Cadavers

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Greher, Manfred; Moriggl, Bernhard

    2018-01-01

    of the femoral nerve. Methods: Fifteen cadaver sides were injected with 5 mL dye in the iliopsoas plane guided by ultrasound. Dissection was performed to verify the spread of injectate around the hip articular branches of the femoral nerve. Results: In 10 dissections (67% [95% confidence interval: 38.......2-32%]) adhesions partially obstructed the spread of dye. Conclusion: An injection of 5 mL in the iliopsoas plane spreads around all hip articular branches of the femoral nerve in 10 of 15 cadaver sides. If these findings translate to living humans, injection of local anaesthetic into the iliopsoas plane could...

  4. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study.

    Science.gov (United States)

    Luo, Jiaquan; Wu, Chunyang; Huang, Zhongren; Pan, Zhimin; Li, Zhiyun; Zhong, Junlong; Chen, Yiwei; Han, Zhimin; Cao, Kai

    2017-04-01

    This is a cadaver specimen study to confirm new pedicle screw (PS) entry point and trajectory for subaxial cervical PS insertion. To assess the accuracy of the lateral vertebral notch-referred PS insertion technique in subaxial cervical spine in cadaver cervical spine. Reported morphometric landmarks used to guide the surgeon in PS insertion show significant variability. In the previous study, we proposed a new technique (as called "notch-referred" technique) primarily based on coronal multiplane reconstruction images (CMRI) and cortical integrity after PS insertion in cadavers. However, the PS position in cadaveric cervical segment was not confirmed radiologically. Therefore, the difference between the pedicle trajectory and the PS trajectory using the notch-referred technique needs to be illuminated. Twelve cadaveric cervical spines were conducted with PS insertion using the lateral vertebral notch-referred technique. The guideline for entry point and trajectory for each vertebra was established based on the morphometric data from our previous study. After 3.5-mm diameter screw insertion, each vertebra was dissected and inspected for pedicle trajectory by CT scan. The pedicle trajectory and PS trajectory were measured and compared in axial plane. The perforation rate was assessed radiologically and was graded from ideal to unacceptable: Grade 0 = screw in pedicle; Grade I = perforation of pedicle wall less than one-fourth of the screw diameter; Grade II = perforation more than one-fourth of the screw diameter but less than one-second; Grade III = perforation more than one-second outside of the screw diameter. In addition, pedicle width between the acceptable and unacceptable screws was compared. A total of 120 pedicle screws were inserted. The perforation rate of pedicle screws was 78.3% in grade 0 (excellent PS position), 10.0% in grade I (good PS position), 8.3% in grade II (fair PS position), and 3.3% in grade III (poor PS position). The

  5. Effects of hydrated lime and quicklime on the decay of buried human remains using pig cadavers as human body analogues.

    Science.gov (United States)

    Schotsmans, Eline M J; Denton, John; Dekeirsschieter, Jessica; Ivaneanu, Tatiana; Leentjes, Sarah; Janaway, Rob C; Wilson, Andrew S

    2012-04-10

    Recent casework in Belgium involving the search for human remains buried with lime, demonstrated the need for more detailed understanding of the effect of different types of lime on cadaver decomposition and its micro-environment. Six pigs (Sus scrofa) were used as body analogues in field experiments. They were buried without lime, with hydrated lime (Ca(OH)(2)) and with quicklime (CaO) in shallow graves in sandy loam soil in Belgium and recovered after 6 months of burial. Observations from these field recoveries informed additional laboratory experiments that were undertaken at the University of Bradford, UK. The combined results of these studies demonstrate that despite conflicting evidence in the literature, hydrated lime and quicklime both delay the decay of the carcass during the first 6 months. This study has implications for the investigation of clandestine burials and for a better understanding of archaeological plaster burials. Knowledge of the effects of lime on decomposition processes also has bearing on practices involving burial of animal carcasses and potentially the management of mass graves and mass disasters by humanitarian organisations and DVI teams. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Does Endoscopic Piriformis Tenotomy Provide Safe and Complete Tendon Release? A Cadaver Study.

    Science.gov (United States)

    Coulomb, Rémy; Khelifi, Anis; Bertrand, Martin; Mares, Olivier; May, Olivier; Marchand, Philippe; Kouyoumdjian, Pascal

    2018-05-28

    Endoscopic piriformis release (EPR) is among the available treatments for piriformis syndrome. This procedure typically involves dividing the muscle near the sciatic nerve in the sub-gluteal space, which contains numerous blood vessels and nerves. The objectives of this prospective cadaver study were: 1) to assess the reproducibility and quality of endoscopic piriformis tenotomy near the greater trochanter; 2) to detect iatrogenic injuries to the lateral hip rotators, nerves, and vessels; 3) and to define the surgical safety margins relative to the sciatic nerve and inferior gluteal bundle. EPR at the greater trochanter ensures full release of the muscle with a limited risk of neuro-vascular injury. EPR was performed via two portals on 10 cadaver hips preserved in zinc chloride and placed in the prone position. A third, ancillary portal was required in 7 cases. The area was then dissected with the Kocher-Langenbeck approach to allow an assessment of the tenotomy, detect iatrogenic injuries, and measure the distances separating the tenotomy site from the sciatic nerve and inferior gluteal artery. Complete tenotomy was achieved in 9 (90%) cases. The tendon adhered to the capsule in 2 (20%) cases and showed acquired avulsion in 1 case. No injuries to the sciatic nerve or inferior gluteal artery occurred. Mean distances from the tenotomy site were 5.21±0.59cm (range, 4.5-6.6cm) for the sciatic nerve and 7.1±0.89cm (range, 5.4-8.5cm) for the inferior gluteal artery. EPR by a tenotomy at the greater trochanter without sciatic nerve release provides full release of the muscle with satisfactory safety margins and a short learning curve. III, prospective cadaver case-control study. Copyright © 2018. Published by Elsevier Masson SAS.

  7. Cadavers Can Be Useful in Teaching Anatomy in College.

    Science.gov (United States)

    Stencel, John; Moore, John

    1989-01-01

    Presents information on student interest, teaching problems, and learning outcomes regarding the use of cadavers as a teaching tool. Provides a list of Illinois Community Colleges using cadavers and a student questionnaire. (RT)

  8. Cadaver-based training is superior to simulation training for cricothyrotomy and tube thoracostomy.

    Science.gov (United States)

    Takayesu, James Kimo; Peak, David; Stearns, Dana

    2017-02-01

    Emergency medicine (EM) training mandates that residents be able to competently perform low-frequency critical procedures upon graduation. Simulation is the main method of training in addition to clinical patient care. Access to cadaver-based training is limited due to cost and availability. The relative fidelity and perceived value of cadaver-based simulation training is unknown. This pilot study sought to describe the relative value of cadaver training compared to simulation for cricothyrotomy and tube thoracostomy. To perform a pilot study to assess whether there is a significant difference in fidelity and educational experience of cadaver-based training compared to simulation training. To understand how important this difference is in training residents in low-frequency procedures. Twenty-two senior EM residents (PGY3 and 4) who had completed standard simulation training on cricothyrotomy and tube thoracostomy participated in a formalin-fixed cadaver training program. Participants were surveyed on the relative fidelity of the training using a 100 point visual analogue scale (VAS) with 100 defined as equal to performing the procedure on a real patient. Respondents were also asked to estimate how much the cadaveric training improved the comfort level with performing the procedures on a scale between 0 and 100 %. Open-response feedback was also collected. The response rate was 100 % (22/22). The average fidelity of the cadaver versus simulation training was 79.9 ± 7.0 vs. 34.7 ± 13.4 for cricothyrotomy (p Cadaver-based training provides superior landmark and tissue fidelity compared to simulation training and may be a valuable addition to EM residency training for certain low-frequency procedures.

  9. Surface Projection of Interosseous Foramen of the Leg: Cadaver Study

    Directory of Open Access Journals (Sweden)

    Eric Arguello

    2016-01-01

    Full Text Available Purpose. This study was conducted to identify the surface projection of the interosseous foramen and associated structures of the proximal leg using the average clinician’s thumb width as a quick measurement to assist in differential diagnosis and treatment. Methods. Twelve cadavers (5 males and 7 females, age range = 51–91 years, and mean age = 76.9 were dissected for analysis. Location and size of interosseous foramen, location of anterior tibial artery, location of deep fibular nerve, and corresponding arterial branches were measured and converted into thumb widths. Results. Mean thumb width measured among the cadavers was 17.94±3.9 mm. The interosseous foramen measured was approximately 1 thumb width vertically (18.47±3.0 mm and 1/2 thumb width horizontally (7.32±2.1 mm and was located approximately 1 thumb width distally to the tibial tuberosity (20.81±6.8 mm and 2 thumb widths (37.47±4.7 mm lateral to the tibial ridge. The anterior tibial artery and deep fibular nerve converged approximately 4 thumb widths (74.31±14.8 mm inferior to the tibial tuberosity and 2 thumb widths (33.46±4.9 mm lateral to the tibial ridge. Conclusion. Clinicians may identify anatomical structures of the proximal leg with palpation using the thumb width for measurement.

  10. SIM Life: a new surgical simulation device using a human perfused cadaver.

    Science.gov (United States)

    Faure, J P; Breque, C; Danion, J; Delpech, P O; Oriot, D; Richer, J P

    2017-02-01

    In primary and continuing medical education, simulation is becoming a mandatory technique. In surgery, simulation spreading is slowed down by the distance which exists between the devices currently available on the market and the reality, in particular anatomical, of an operating room. We propose a new model for surgical simulation with the use of cadavers in a circulation model mimicking pulse and artificial respiration available for both open and laparoscopic surgery. The model was a task trainer designed by four experts in our simulation laboratory combining plastic, electronic, and biologic material. The cost of supplies needed for the construction was evaluated. The model was used and tested over 24 months on 35 participants, of whom 20 were surveyed regarding the realism of the model. The model involved a cadaver, connected to a specific device that permits beating circulation and artificial respiration. The demonstration contributed to teaching small groups of up to four participants and was reproducible over 24 months of courses. Anatomic correlation, realism, and learning experience were highly rated by users CONCLUSION: This model for surgical simulation in both open and laparoscopic surgery was found to be realistic, available to assessed objectively performance in a pedagogic program.

  11. Analysis of ureteral length in adult cadavers

    Directory of Open Access Journals (Sweden)

    Hugo F. F. Novaes

    2013-04-01

    Full Text Available Introduction In some occasions, correlations between human structures can help planning surgical intra-abdominal interventions. The previous determination of ureteral length helps pre-operatory planning of surgeries, reduces costs of auxiliary exams, the correct choice of double-J catheter with low morbidity and fewer symptoms, and an adequate adhesion to treatment. Objective To evaluate ureteral length in adult cadavers and to analyze its correlation with anthropometric measures. Materials and Methods: From April 2009 to January 2012 we determined ureteral length of adult cadavers submitted to necropsy and obtained the following measures: height, distance from shoulder to wrist, elbow-wrist, xiphoid appendix-umbilicus, umbilicus-pubis, xiphoid appendix-pubis and between iliac spines. We analyzed the correlations between ureteral length and those anthropometric measures. Results We dissected 115 ureters from 115 adult corpses from April 2009 to January 2012. Median ureteral length didn't vary between sexes or according to height. It was observed no correlation among ureteral length and all considered anthropometric measures in all analyzed subgroups and in general population. There were no significant differences between right and left ureteral measures. Conclusions There is no difference of ureteral length in relation to height or gender (male or female. There is no significant correlation among ureteral length and the considered anthropometric measures.

  12. Cling film plastic wrap: An innovation for dead body packaging, preservation and transportation by first responders as a replacement for cadaver body bag in large scale disasters.

    Science.gov (United States)

    Khoo, Lay See; Lai, Poh Soon; Saidin, Mohd Hilmi; Noor, Zahari; Mahmood, Mohd Shah

    2018-04-01

    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Development of an ultrasound-guided technique for pudendal nerve block in cat cadavers.

    Science.gov (United States)

    Adami, Chiara; Angeli, Giovanni; Haenssgen, Kati; Stoffel, Michael H; Spadavecchia, Claudia

    2013-10-01

    The objective of this prospective experimental cadaveric study was to develop an ultrasound-guided technique to perform an anaesthetic pudendal nerve block in male cats. Fifteen fresh cadavers were used for this trial. A detailed anatomical dissection was performed on one cat in order to scrutinise the pudendal nerve and its ramifications. In a second step, the cadavers of six cats were used to test three different ultrasonographic approaches to the pudendal nerve: the deep dorso-lateral, the superficial dorso-lateral and the median transperineal. Although none of the approaches allowed direct ultrasonographical identification of the pudendal nerve branches, the deep dorso-lateral was found to be the most advantageous one in terms of practicability and ability to identify useful and reliable landmarks. Based on these findings, the deep dorso-lateral approach was selected as technique of choice for tracer injections (0.1 ml 1% methylene blue injected bilaterally) in six cat cadavers distinct from those used for the ultrasonographical study. Anatomical dissection revealed a homogeneous spread of the tracer around the pudendal nerve sensory branches in all six cadavers. Finally, computed tomography was performed in two additional cadavers after injection of 0.3 ml/kg (0.15 ml/kg per each injection sites, left and right) contrast medium through the deep dorso-lateral approach in order to obtain a model of volume distribution applicable to local anaesthetics. Our findings in cat cadavers indicate that ultrasound-guided pudendal nerve block is feasible and could be proposed to provide peri-operative analgesia in clinical patients undergoing perineal urethrostomy.

  14. Fabrication and characterization of scaffold from cadaver goat-lung tissue for skin tissue engineering applications.

    Science.gov (United States)

    Gupta, Sweta K; Dinda, Amit K; Potdar, Pravin D; Mishra, Narayan C

    2013-10-01

    The present study aims to fabricate scaffold from cadaver goat-lung tissue and evaluate it for skin tissue engineering applications. Decellularized goat-lung scaffold was fabricated by removing cells from cadaver goat-lung tissue enzymatically, to have cell-free 3D-architecture of natural extracellular matrix. DNA quantification assay and Hematoxylin and eosin staining confirmed the absence of cellular material in the decellularized lung-tissue. SEM analysis of decellularized scaffold shows the intrinsic porous structure of lung tissue with well-preserved pore-to-pore interconnectivity. FTIR analysis confirmed non-denaturation and well maintainance of collagenous protein structure of decellularized scaffold. MTT assay, SEM analysis and H&E staining of human skin-derived Mesenchymal Stem cell, seeded over the decellularized scaffold, confirms stem cell attachment, viability, biocompatibility and proliferation over the decellularized scaffold. Expression of Keratin18 gene, along with CD105, CD73 and CD44, by human skin-derived Mesenchymal Stem cells over decellularized scaffold signifies that the cells are viable, proliferating and migrating, and have maintained their critical cellular functions in the presence of scaffold. Thus, overall study proves the applicability of the goat-lung tissue derived decellularized scaffold for skin tissue engineering applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Alfuzosin hydrochloride transdermal films: evaluation of physicochemical, in vitro human cadaver skin permeation and thermodynamic parameters

    Directory of Open Access Journals (Sweden)

    Satyanarayan Pattnaik

    2009-12-01

    Full Text Available Purpose: The main objective of the investigation was to develop a transdermal therapeutic system for alfuzosin hydrochloride and to study the effects of polymeric system and loading dose on the in vitro skin permeation pattern. Materials and methods: Principles of experimental design have been exploited to develop the dosage form. Ratio of ethyl cellulose (EC and polyvinyl pyrrolidone (PVP and loading dose were selected as independent variables and their influence on the cumulative amount of alfuzosin hydrochloride permeated per cm2 of human cadaver skin at 24 h (Q24, permeation flux (J and steady state permeability coefficient (P SS were studied using experimental design. Various physicochemical parameters of the transdermal films were also evaluated. Activation energy for in vitro transdermal permeation has been estimated. Results: Ratio of EC and PVP was found to be the main influential factor for all the dependent variables studied. Drug loading dose was also found to influence the dependent variables but to a lesser extent. Physicochemical parameters of the prepared films were evaluated and found satisfactory. Activation energy for alfuzosin permeation has also been estimated and reported. Conclusion: The therapeutic system was found to be dermatologically non-irritant and hence, a therapeutically effective amount of alfuzosin hydrochloride can be delivered via a transdermal route.

  16. Reprint of: Cling film plastic wrap: An innovation for dead body packaging, preservation and transportation by first responders as a replacement for cadaver body bag in large scale disasters.

    Science.gov (United States)

    Khoo, Lay See; Lai, Poh Soon; Saidin, Mohd Hilmi; Noor, Zahari; Mahmood, Mohd Shah

    2018-07-01

    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Diet influences rates of carbon and nitrogen mineralization from decomposing grasshopper frass and cadavers

    Science.gov (United States)

    Insect herbivory can produce a pulse of mineral nitrogen (N) in soil from the decomposition of frass and cadavers. In this study we examined how diet quality affects rates of N and carbon (C) mineralization from grasshopper frass and cadavers. Frass was collected from grasshoppers fed natural or mer...

  18. HLA AND CROSS·REACTIVE ANTIGEN GROUP MATCHING FOR CADAVER KIDNEY ALLOCATION1

    Science.gov (United States)

    Starzl, Thomas E.; Eliasziw, Michael; Gjertson, David; Terasaki, Paul I.; Fung, John J.; Trucco, Massimo; Martell, Joan; McMichael, John; Scantlebury, Velma; Shapiro, Ron; Donner, Allan

    2010-01-01

    Background Allocation of cadaver kidneys by graded human leukocyte antigen (HLA) compatibility scoring arguably has had little effect on overall survival while prejudicing the transplant candidacy of African-American and other hard to match populations. Consequently, matching has been proposed of deduced amino acid residues of the individual HLA molecules shared by cross-reactive antigen groups (CREGs). We have examined the circumstances under which compatibility with either method impacted graft survival. Methods Using Cox proportional hazards regression modeling, we studied the relationship between levels of conventional HLA mismatch and other donor and recipient factors on primary cadaver kidney survival between 1981 and 1995 at the University of Pittsburgh (n=1,780) and in the United Network for Organ Sharing (UNOS) Scientific Registry during 1991–1995 (n=31,291). The results were compared with those obtained by the matching of amino acid residues that identified CREG-compatible cases with as many as four (but not five and six) HLA mismatches. Results With more than one HLA mismatch (>85% of patients in both series), most of the survival advantage of a zero mismatch was lost. None of the HLA loci were “weak.” In the UNOS (but not Pittsburgh) category of one-HLA mismatch (n=1334), a subgroup of CREG-matched recipients (35.3%) had better graft survival than the remaining 64.7%, who were CREG-mismatched. There was no advantage of a CREG match in the two- to four-HLA incompatibility tiers. Better graft survival with tacrolimus was observed in both the Pittsburgh and UNOS series. Conclusions Obligatory national sharing of cadaver kidneys is justifiable only for zero-HLA-mismatched kidneys. The potential value of CREG matching observed in the one-HLA-mismatched recipients of the UNOS (but not the Pittsburgh) experience deserves further study. PMID:9381546

  19. Pathological study of degenerative changes of finger joints in cadavers of aged persons

    OpenAIRE

    岩田,芳之

    1987-01-01

    In the present study, soft x-ray and light microscopic examinations were carried out on 17 interphalangeal (IP) joints and 85 distal interphalangeal (DIP) joints with Heberden's nodes from 15 cadavers. Microradiograms of the IP and DIP joints were analyzed as to the degenerative changes in the antero-posterior and lateral views according to our own criteria. Degenerative changes were more severe in females than in males. Advanced degeneration was found in the index, middle and little fingers,...

  20. Current Status of Cadaver Sources in Turkey and a Wake-Up Call for Turkish Anatomists

    Science.gov (United States)

    Gürses, Ilke Ali; Coskun, Osman; Öztürk, Adnan

    2018-01-01

    Persisting difficulties in body procurement in Turkey led to the acquisition of donated, unclaimed, autopsied, and imported bodies regulated under current legislature. Yet, no study had investigated the extent of the on-going cadaver problem. This study was aimed to outline cadaver sources in anatomy departments and their effectiveness by means of…

  1. Distribution of sensory nerve endings around the human sinus tarsi: a cadaver study

    Science.gov (United States)

    Rein, Susanne; Manthey, Suzanne; Zwipp, Hans; Witt, Andreas

    2014-01-01

    The aim of this study was to analyse the pattern of sensory nerve endings and blood vessels around the sinus tarsi. The superficial and deep parts of the fat pads at the inferior extensor retinaculum (IER) as well as the subtalar joint capsule inside the sinus tarsi from 13 cadaver feet were dissected. The distribution of the sensory nerve endings and blood vessels were analysed in the resected specimens as the number per cm2 after staining with haematoxylin-eosin, S100 protein, low-affinity neurotrophin receptor p75, and protein gene product 9.5 using the classification of Freeman and Wyke. Free nerve endings were the predominant sensory ending (P < 0.001). Ruffini and Golgi-like endings were rarely found and no Pacini corpuscles were seen. Significantly more free nerve endings (P < 0.001) and blood vessels (P = 0.01) were observed in the subtalar joint capsule than in the superficial part of the fat pad at the IER. The deep part of the fat pad at the IER had significantly more blood vessels than the superficial part of the fat pad at the IER (P = 0.012). Significantly more blood vessels than free nerve endings were seen in all three groups (P < 0.001). No significant differences in distribution were seen in terms of right or left side, except for free nerve endings in the superficial part of the fat pad at the IER (P = 0.003). A greater number of free nerve endings correlated with a greater number of blood vessels. The presence of sensory nerve endings between individual fat cells supports the hypothesis that the fat pad has a proprioceptive role monitoring changes and that it is a source of pain in sinus tarsi syndrome due to the abundance of free nerve endings. PMID:24472004

  2. Upper and Lower Urinary Tract Endoscopy Training on Thiel-embalmed Cadavers.

    Science.gov (United States)

    Bele, Uros; Kelc, Robi

    2016-07-01

    To evaluate Thiel-embalmed cadavers as a new training model for urological endoscopy procedures. Twelve urologists performed upper and lower urinary tract endoscopies on 5 different Thiel-embalmed cadavers to evaluate this potentially new training model in urological endoscopic procedural training. Using a 5-point Likert scale, the participants assessed the quality of the tissue and the overall experience of the endoscopy in comparison to a live patient procedure. Thiel-embalmed cadavers have shown to mimic live patient endoscopy of the upper and lower urinary tract in terms of almost identical overall anatomical conditions and manipulation characteristics of the tissue. The mucosa of the urethra and ureters showed similar colors and consistency in comparison to a live patient, whereas bladder mucosa was lacking the visibility of the vessels, thus was unsuitable for identifying any mucosal abnormalities. The flexibility of the muscles allowed for proper patient positioning, whereas the loss of muscle tonus made ureteroscopy more difficult although sufficiently comparable to the procedure done in a live patient. Thiel-embalmed cadavers have already been proven to be a suitable training model for several medical procedures. They are known for preserving tissue color, consistency, and flexibility without the irritant odors or risk of infection, which make them resemble live patients with real-life surgical challenges. The results of our study strongly suggest that despite some minor drawbacks, Thiel-embalmed cadavers are a suitable simulation model for initial training of urethrocystoscopy and ureteroscopy. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Prediction of skull fracture risk for children 0-9 months old through validated parametric finite element model and cadaver test reconstruction.

    Science.gov (United States)

    Li, Zhigang; Liu, Weiguo; Zhang, Jinhuan; Hu, Jingwen

    2015-09-01

    Skull fracture is one of the most common pediatric traumas. However, injury assessment tools for predicting pediatric skull fracture risk is not well established mainly due to the lack of cadaver tests. Weber conducted 50 pediatric cadaver drop tests for forensic research on child abuse in the mid-1980s (Experimental studies of skull fractures in infants, Z Rechtsmed. 92: 87-94, 1984; Biomechanical fragility of the infant skull, Z Rechtsmed. 94: 93-101, 1985). To our knowledge, these studies contained the largest sample size among pediatric cadaver tests in the literature. However, the lack of injury measurements limited their direct application in investigating pediatric skull fracture risks. In this study, 50 pediatric cadaver tests from Weber's studies were reconstructed using a parametric pediatric head finite element (FE) model which were morphed into subjects with ages, head sizes/shapes, and skull thickness values that reported in the tests. The skull fracture risk curves for infants from 0 to 9 months old were developed based on the model-predicted head injury measures through logistic regression analysis. It was found that the model-predicted stress responses in the skull (maximal von Mises stress, maximal shear stress, and maximal first principal stress) were better predictors than global kinematic-based injury measures (peak head acceleration and head injury criterion (HIC)) in predicting pediatric skull fracture. This study demonstrated the feasibility of using age- and size/shape-appropriate head FE models to predict pediatric head injuries. Such models can account for the morphological variations among the subjects, which cannot be considered by a single FE human model.

  4. Dynamic Response and Residual Helmet Liner Crush Using Cadaver Heads and Standard Headforms.

    Science.gov (United States)

    Bonin, S J; Luck, J F; Bass, C R; Gardiner, J C; Onar-Thomas, A; Asfour, S S; Siegmund, G P

    2017-03-01

    Biomechanical headforms are used for helmet certification testing and reconstructing helmeted head impacts; however, their biofidelity and direct applicability to human head and helmet responses remain unclear. Dynamic responses of cadaver heads and three headforms and residual foam liner deformations were compared during motorcycle helmet impacts. Instrumented, helmeted heads/headforms were dropped onto the forehead region against an instrumented flat anvil at 75, 150, and 195 J. Helmets were CT scanned to quantify maximum liner crush depth and crush volume. General linear models were used to quantify the effect of head type and impact energy on linear acceleration, head injury criterion (HIC), force, maximum liner crush depth, and liner crush volume and regression models were used to quantify the relationship between acceleration and both maximum crush depth and crush volume. The cadaver heads generated larger peak accelerations than all three headforms, larger HICs than the International Organization for Standardization (ISO), larger forces than the Hybrid III and ISO, larger maximum crush depth than the ISO, and larger crush volumes than the DOT. These significant differences between the cadaver heads and headforms need to be accounted for when attempting to estimate an impact exposure using a helmet's residual crush depth or volume.

  5. Flexible Vesiculovasoscopy Using a Microoptical System in a Human Cadaver Model: An Experimental Approach for Atraumatic Endoscopy of the Seminal Tract.

    Science.gov (United States)

    Schlager, Daniel; Maas, Moritz; Hein, Simon; Adams, Fabian; Schoenthaler, Martin; Wetterauer, Ulrich; Diemer, Thorsten; Weidner, Wolfgang; Miernik, Arkadiusz

    2016-08-01

    The most common pathologies of the seminal tract are persistent hematospermia, seminal vesicle stones, and seminal duct obstruction. Endoscopic diagnostic work-up of the seminal tract is impeded by complex anatomy and lack of technical equipment. To date, there is no standardized endoscopic approach. The purpose of this study was to investigate the applicability and feasibility of a flexible microoptical device for atraumatic endoscopy of the seminal tract in a male human cadaver. The transurethral endoscopic examination was performed on a male cadaver. No premortal interventions or diseases of the genitourinary tract had been reported. The seminal orifice was identified via cystoscopy and accessed by the Seldinger technique using a hydrophilic guidewire and ureteral catheter. Retrograde endoscopic inspection of the distal seminal tract was performed using a miniaturized flexible endoscope. An antegrade endoscopic inspection of the seminal tract was carried out via high scrotal access to the vas deferens. Structures of the seminal tract, such as the ejaculatory duct, seminal vesicles, and distal portion of the ductus deferentes, were visualized using the miniaturized endoscope. Image quality allowed identification of anatomical structures and characterization of tissue properties. The technical limitations we observed involved the system's maneuverability. Initial results of this novel endoscopic approach to the seminal tract using a flexible microoptical system are encouraging. However, considerable anatomical limitations of the targeted organs necessitate further refinements of the technical equipment. This approach might improve diagnostics and treatment of genitourinary diseases. Future surgical techniques may include intraseminal laser therapy or endoocclusion to monitor fertility in men.

  6. Optimizing CT technique to reduce radiation dose: effect of changes in kVp, iterative reconstruction, and noise index on dose and noise in a human cadaver.

    Science.gov (United States)

    Chang, Kevin J; Collins, Scott; Li, Baojun; Mayo-Smith, William W

    2017-06-01

    For assessment of the effect of varying the peak kilovoltage (kVp), the adaptive statistical iterative reconstruction technique (ASiR), and automatic dose modulation on radiation dose and image noise in a human cadaver, a cadaver torso underwent CT scanning at 80, 100, 120 and 140 kVp, each at ASiR settings of 0, 30 and 50 %, and noise indices (NIs) of 5.5, 11 and 22. The volume CT dose index (CTDI vol ), image noise, and attenuation values of liver and fat were analyzed for 20 data sets. Size-specific dose estimates (SSDEs) and liver-to-fat contrast-to-noise ratios (CNRs) were calculated. Values for different combinations of kVp, ASiR, and NI were compared. The CTDI vol varied by a power of 2 with kVp values between 80 and 140 without ASiR. Increasing ASiR levels allowed a larger decrease in CTDI vol and SSDE at higher kVp than at lower kVp while image noise was held constant. In addition, CTDI vol and SSDE decreased with increasing NI at each kVp, but the decrease was greater at higher kVp than at lower kVp. Image noise increased with decreasing kVp despite a fixed NI; however, this noise could be offset with the use of ASiR. The CT number of the liver remained unchanged whereas that of fat decreased as the kVp decreased. Image noise and dose vary in a complicated manner when the kVp, ASiR, and NI are varied in a human cadaver. Optimization of CT protocols will require balancing of the effects of each of these parameters to maximize image quality while minimizing dose.

  7. The Wider Importance of Cadavers: Educational and Research Diversity from a Body Bequest Program

    Science.gov (United States)

    Cornwall, Jon; Stringer, Mark D.

    2009-01-01

    The debate surrounding the use of cadavers in teaching anatomy has focused almost exclusively on the pedagogic role of cadaver dissection in medical education. The aim of this study was to explore the wider aspects of a body bequest program for teaching and research into gross anatomy in a University setting. A retrospective audit was undertaken…

  8. Return of the cadaver

    Science.gov (United States)

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-01-01

    Abstract Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques. In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised. Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study. Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures. PMID:28723767

  9. Simulated training in colonoscopic stenting of colonic strictures: validation of a cadaver model.

    Science.gov (United States)

    Iordache, F; Bucobo, J C; Devlin, D; You, K; Bergamaschi, R

    2015-07-01

    There are currently no available simulation models for training in colonoscopic stent deployment. The aim of this study was to validate a cadaver model for simulation training in colonoscopy with stent deployment for colonic strictures. This was a prospective study enrolling surgeons at a single institution. Participants performed colonoscopic stenting on a cadaver model. Their performance was assessed by two independent observers. Measurements were performed for quantitative analysis (time to identify stenosis, time for deployment, accuracy) and a weighted score was devised for assessment. The Mann-Whitney U-test and Student's t-test were used for nonparametric and parametric data, respectively. Cohen's kappa coefficient was used for reliability. Twenty participants performed a colonoscopy with deployment of a self-expandable metallic stent in two cadavers (groups A and B) with 20 strictures overall. The median time was 206 s. The model was able to differentiate between experts and novices (P = 0. 013). The results showed a good consensus estimate of reliability, with kappa = 0.571 (P cadaver model described in this study has content, construct and concurrent validity for simulation training in colonoscopic deployment of self-expandable stents for colonic strictures. Further studies are needed to evaluate the predictive validity of this model in terms of skill transfer to clinical practice. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  10. Validation of an optical system to measure acetabular shell deformation in cadavers.

    Science.gov (United States)

    Dold, Philipp; Bone, Martin C; Flohr, Markus; Preuss, Roman; Joyce, Tom J; Deehan, David; Holland, James

    2014-08-01

    Deformation of the acetabular shell at the time of surgery can result in poor performance and early failure of the hip replacement. The study aim was to validate an ATOS III Triple Scan optical measurement system against a co-ordinate measuring machine using in vitro testing and to check repeatability under cadaver laboratory conditions. Two sizes of custom-made acetabular shells were deformed using a uniaxial/two-point loading frame and measured at different loads. Roundness measurements were performed using both the ATOS III Triple Scan optical system and a co-ordinate measuring machine and then compared. The repeatability was also tested by measuring shells pre- and post-insertion in a cadaver laboratory multiple times. The in vitro comparison with the co-ordinate measuring machine demonstrated a maximum difference of 5 µm at the rim and 9 µm at the measurement closest to the pole of the shell. Maximum repeatability was below 1 µm for the co-ordinate measuring machine and 3 µm for the ATOS III Triple Scan optical system. Repeatability was comparable between the pre-insertion (below 2 µm) and post-insertion (below 3 µm) measurements in the cadaver laboratory. This study supports the view that the ATOS III Triple Scan optical system fulfils the necessary requirements to accurately measure shell deformation in cadavers. © IMechE 2014.

  11. Comparison of 2 canal preparation techniques in the induction of microcracks: a pilot study with cadaver mandibles.

    Science.gov (United States)

    Arias, Ana; Lee, Yoon H; Peters, Christine I; Gluskin, Alan H; Peters, Ove A

    2014-07-01

    The purpose of this pilot study in a cadaver model was to compare 2 different shaping techniques regarding the induction of dentinal microcracks. Three lower incisors from each of 6 adult human cadaver skulls were randomly distributed into 3 groups: the control group (CG, no instrumentation), the GT group (GT Profile hand files; Dentsply Tulsa Dental, Tulsa, OK), and the WO group (WaveOne; Dentsply Tulsa Dental). In the GT group, manual shaping in a crown-down sequence with GT Profile hand files was performed. In the WO group, Primary WaveOne files were used to the working length. Teeth were separated from the mandibles by careful removal of soft tissue and bone under magnification. Roots were sectioned horizontally at 3, 6, and 9 mm from the apex using a low-speed saw. Color photographs at 2 magnifications (25× and 40×) were obtained. Three blinded examiners registered the presence of microcracks (yes/no), extension (incomplete/complete), direction (buccolingual/mesiodistal), and location. Data were analyzed with chi-square tests at P < .05. Microcracks were found in 50% (CG and GT) and 66% (WO) of teeth at 3 mm, 16.6% (CG) and 33.3% (GT and WO) at 6 mm, and 16.6% in all 3 groups at 9 mm from the apex. There were no significant differences in the incidence of microcracks between all groups at 3 (P = .8), 6 (P = .8), or 9 mm (P = 1). All microcracks were incomplete, started at the pulpal wall, and had a buccolingual direction. Within the limitations of this pilot study, a relationship between the shaping techniques (GT hand and WaveOne) and the incidence of microcracks could not be shown compared with uninstrumented controls. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. The dural entrance of cerebral bridging veins into the superior sagittal sinus: an anatomical comparison between cadavers and digital subtraction angiography

    International Nuclear Information System (INIS)

    Han, Hui; Tao, Wei; Zhang, Ming

    2007-01-01

    Intracranial venous structures have received increasing attention due to improved neuroimaging techniques and increased awareness of cerebral venous disease. To date, few studies have attempted to investigate the dural entrance of the cerebral bridging vein (BV). The aim of this study was to use the superior sagittal sinus (SSS) as an example to identify anatomical features of the dural entrance of the BVs into the SSS in both human cadavers and digital subtraction angiography (DSA) images. A total of 30 adult and 7 fetal human cadavers and 36 patients were examined with anatomical dissections, vascular casting and DSA. The number, diameter and angle of the BVs entering the SSS were measured and compared between the cadavers and DSA images. The results demonstrated that (1) the way a BV entered the SSS varied in three dimensions, and thus the BV dural entrance was difficult to precisely localize by DSA, (2) the distribution pattern of the dural entrance of the BVs into the SSS was relatively constant and a nontributary segment of the SSS was centered at the coronal suture and was identifiable by DSA, and (3) nearly all the BVs (97%, 561/581) entered the SSS at an angle opposite to the direction of blood flow. Unique anatomical features of the dural entrance of a BV into the SSS should be considered in neuroimaging interpretation of the sinus and its associated veins. (orig.)

  13. Evaluation of performance of two different chest tubes with either a sharp or a blunt tip for thoracostomy in 100 human cadavers

    Directory of Open Access Journals (Sweden)

    Ortner Clemens M

    2012-02-01

    Full Text Available Abstract Background Emergent placement of a chest tube is a potentially life-saving procedure, but rate of misplacement and organ injury is up to 30%. In principle, chest tube insertion can be performed by using Trocar or Non-trocar techniques. If using trocar technique, two different chest tubes (equipped with sharp or blunt tip are currently commercially available. This study was performed to detect any difference with respect to time until tube insertion, to success and to misplacement rate. Methods Twenty emergency physicians performed five tube thoracostomies using both blunt and sharp tipped tube kits in 100 fresh human cadavers (100 thoracostomies with each kit. Time until tube insertion served as primary outcome. Complications and success rate were examined by pathological dissection and served as further outcomes parameters. Results Difference in mean time until tube insertion (63s vs. 59s was statistically not significant. In both groups, time for insertion decreased from the 1st to the 5th attempt and showed dependency on the cadaver's BMI and on the individual physician. Success rate differed between both groups (92% using blunt vs. 86% using sharp tipped kits and injuries and misplacements occurred significantly more frequently using chest tubes with sharp tips (p = 0.04. Conclusion Data suggest that chest drain insertion with trocars is associated with a 6-14% operator-related complication rate. No difference in average time could be found. However, misplacements and organ injuries occurred more frequently using sharp tips. Consequently, if using a trocar technique, the use of blunt tipped kits is recommended.

  14. perception to cadaver dissection and views on anatomy as a subject

    African Journals Online (AJOL)

    However, literature on medical students' perceptions on cadaver dissection and their opinions on anatomy as a subject is scanty ... Key words: Dissection, Perceptions, Cadaver, Anatomy. INTRODUCTION. Dissection has been the .... attention they give to the learning of anatomy, and this may possibly explain the relatively.

  15. A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations

    Science.gov (United States)

    Li, Xinhua; Shi, Jim Q.; Zhang, Da; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Kalra, Mannudeep K.; Xu, X. George; Liu, Bob

    2015-01-01

    Purpose: To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. Methods: A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was used to simultaneously detect radiation levels across a scan field-of-view. The sampling time was as short as 0.24 ms. To measure the body bow-tie attenuation on a GE Lightspeed Pro 16 CT scanner, the x-ray tube was parked at the 12 o’clock position, and the detector was centered in the scan field at the isocenter height. Two radiation exposures were made with and without the bow-tie in the beam path. Each readout signal was corrected for the detector background offset and signal-level related nonlinear gain, and the ratio of the two exposures gave the bow-tie attenuation. The results were used in the geant4 based simulations of the point doses measured using six thimble chambers placed in a human cadaver with abdomen/pelvis CT scans at 100 or 120 kV, helical pitch at 1.375, constant or variable tube current, and distinct x-ray tube starting angles. Results: Absolute attenuation was measured with the body bow-tie scanned at 80–140 kV. For 24 doses measured in six organs of the cadaver, the median or maximum difference between the simulation results and the measurements on the CT scanner was 8.9% or 25.9%, respectively. Conclusions: The described method allows fast and accurate bow-tie filter characterization. PMID:26520720

  16. A Randomized Cadaver Study Comparing First-Attempt Success Between Tibial and Humeral Intraosseous Insertions Using NIO Device by Paramedics: A Preliminary Investigation.

    Science.gov (United States)

    Szarpak, Lukasz; Truszewski, Zenon; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Adamczyk, Piotr; Czyzewski, Lukasz

    2016-05-01

    Medical personnel may encounter difficulties in obtaining intravenous (IV) access during cardiac arrest. The 2015 American Heart Association guidelines and the 2015 European Resuscitation Council guidelines for cardiopulmonary resuscitation (CPR) suggest that rescuers establish intraosseous (IO) access if an IV line is not easily obtainable.The aim of the study was to compare the success rates of the IO proximal tibia and proximal humerus head access performed by paramedics using the New Intraosseous access device (NIO; Persys Medical, Houston, TX, USA) in an adult cadaver model during simulated CPR.In an interventional, randomized, crossover, single-center cadaver study, a semi-automatic spring-load driven NIO access device was investigated. In total, 84 paramedics with less than 5-year experience in Emergency Medical Service participated in the study. The trial was performed on 42 adult cadavers. In each cadaver, 2 IO accesses to the humerus head, and 2 IO accesses to the proximal tibia were obtained.The success rate of the first IO attempt was 89.3% (75/84) for tibial access, and 73.8% (62/84) for humeral access (P = 0.017). The procedure times were significantly faster for tibial access [16.8 (interquartile range, IQR, 15.1-19.9] s] than humeral access [26.7 (IQR, 22.1-30.9) s] (P < 0.001).Tibial IO access is easier and faster to put in place than humeral IO access. Humeral IO access can be an alternative method to tibial IO access. clinicaltrials.gov Identifier: NCT02700867.

  17. The effect of scapular position on subacromial contact behavior: a cadaver study.

    Science.gov (United States)

    Muraki, Takayuki; Yamamoto, Nobuyuki; Sperling, John W; Steinmann, Scott P; Cofield, Robert H; An, Kai-Nan

    2017-05-01

    Patients with subacromial impingement were reported to show abnormal scapular positions during shoulder elevation. However, the relationship between the scapular positions and subacromial impingement is unclear. The purpose of this study was to biomechanically determine the effect of scapular position on subacromial contact behavior by using fresh frozen cadavers. The peak contact pressure on the coracoacromial arch was measured with a flexible tactile force sensor in 9 fresh frozen cadaver shoulders. The measurement was performed during passive glenohumeral elevation in the scapular plane ranging from 30° to 75°. The scapular downward and internal rotations and anterior tilt were simulated by tilting the scapula in 5° increments up to 20°. The measurement was also performed with combination of scapular downward and internal rotations and anterior tilt positions. The peak contact pressure decreased linearly with anterior tilt, and a significant difference between neutral scapular position (1.06 ± 0.89 MPa) and anterior tilt by 20° (0.46 ± 0.18 MPa) was observed (P < .05). However, the scapular positioning in the other directions did not change the peak contact pressure significantly. Furthermore, any combination of abnormal scapular positions did not affect peak contact pressure significantly. Scapular anterior tilt decreased peak contact pressure during passive shoulder elevation. In addition, scapular downward and internal rotations had little effect on peak contact pressure. The abnormal scapular motion reported in previous studies might not be directly related to symptoms caused by subacromial impingement. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. Fixed-angle plates in patella fractures - a pilot cadaver study

    Directory of Open Access Journals (Sweden)

    Wild M

    2011-01-01

    Full Text Available Abstract Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge, quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65. Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays

  19. An Economical Approach to Teaching Cadaver Anatomy: A 10-Year Retrospective

    Science.gov (United States)

    Simpson, Jeff S.

    2014-01-01

    Because of shrinking budgets and computerized virtual dissection programs, many large and small institutions are closing the door on traditional and expensive cadaver dissection classes. However, many health-care educators would argue there is still a place for cadaver dissection in higher education, so the continuing challenge is to provide the…

  20. Normal mediastinal lymph node size and shape; CT and cadaver study

    International Nuclear Information System (INIS)

    Im, Chung Kie; Lee, Kyung Soo; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    With the view point of size, shape and arrangement pattern, authors present normal mediastinal lymph node from the analysis of 61 cases of CT scan and multidirectional section of 2 cadavers. The result were as follows: 1. Transverse diameter of the lymph nodes, demonstrated in cadaver section, was 3 to 6mm in upper paratracheal area and 5 to 14mm in juxta-carinal and AP-window area. Arrangement of the lymph nodes showed tendency of longitudinal direction in lower paratracheal, and juxtacarinal area, while that of AP window showed tendency of AP direction as long axis. 2. Mean and the largest size of the lymph nodes demonstrated in CT scan were 3.7mm, 8mm in upper paratracheal area, and 6mm, 12mm in lower paratracheal area, and 7.1mm, 14mm in juxtacarinal area, and 6.3mm and 11mm in aorticopulmonary window area. 3. Size of the lymph nodes in CT scan showed linear increasing tendency according to increasing age (y=0.32, p<0.005). 4. Shape of the lymph nodes in CT scan were mostly round in upper paratracheal area while that of aorticopulmonary window showed higher incidence of oval and elongated shape. 5. Recommended size criterior of abnormal lymph node is 10mm in upper paratracheal area and 15mm in the other area

  1. Cadaver study of anatomic landmark identification for placing ankle arthroscopy portals.

    Science.gov (United States)

    Scheibling, B; Koch, G; Clavert, P

    2017-05-01

    , cadaver study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Disease in the Society: Infectious Cadavers Result in Collapse of Ant Sub-Colonies

    Science.gov (United States)

    Loreto, Raquel G.; Hughes, David P.

    2016-01-01

    Despite the growing number of experimental studies on mechanisms of social immunity in ant societies, little is known about how social behavior relates to disease progression within the nests of ants. In fact, when empirically studying disease in ant societies, it is common to remove dead ants from experiments to confirm infection by the studied parasite. This unfortunately does not allow disease to progress within the nest as it may be assumed would happen under natural conditions. Therefore, the approach taken so far has resulted in a limited knowledge of diseases dynamics within the nest environment. Here we introduced a single infectious cadaver killed by the fungus Beauveria bassiana into small nests of the ant Camponotus castaneus. We then observed the natural progression of the disease by not removing the corpses of the ants that died following the first entry of the disease. Because some behaviors such as social isolation of sick individuals or the removal of cadavers by nestmates are considered social immune functions and thus adaptations at the colony level that reduce disease spread, we also experimentally confined some sub-colonies to one or two chamber nests to prevent the expression of such behaviors. Based on 51 small nests and survival studies in 1,003 ants we found that a single introduced infectious cadaver was able to transmit within the nest, and social immunity did not prevent the collapse of the small sub-colonies here tested. This was true whether ants did or did not have the option to remove the infectious cadaver. Therefore, we found no evidence that the typically studied social immunity behaviors can reduce disease spread in the conditions here tested. PMID:27529548

  3. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Camille Chesnel

    Full Text Available Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia.To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers.Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred.Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%: 4 (1% in tendons or muscles, 3 (0.7% in nerves and 1 (0.2% in a vessel.This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  4. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Science.gov (United States)

    Chesnel, Camille; Genêt, François; Almangour, Waleed; Denormandie, Philippe; Parratte, Bernard; Schnitzler, Alexis

    2015-01-01

    Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning) is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia. To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers. Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons) carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred. Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%): 4 (1%) in tendons or muscles, 3 (0.7%) in nerves and 1 (0.2%) in a vessel. This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  5. Analysis of Dual Mobility Liner Rim Damage Using Retrieved Components and Cadaver Models.

    Science.gov (United States)

    Nebergall, Audrey K; Freiberg, Andrew A; Greene, Meridith E; Malchau, Henrik; Muratoglu, Orhun; Rowell, Shannon; Zumbrunn, Thomas; Varadarajan, Kartik M

    2016-07-01

    The objective of this study was to assess the retentive rim of retrieved dual mobility liners for visible evidence of deformation from femoral neck contact and to use cadaver models to determine if anterior soft tissue impingement could contribute to such deformation. Fifteen surgically retrieved polyethylene liners were assessed for evidence of rim deformation. The average time in vivo was 31.4 months, and all patients were revised for reasons other than intraprosthetic dislocation. Liner interaction with the iliopsoas was studied visually and with fluoroscopy in cadaver specimens using a dual mobility system different than the retrieval study. For fluoroscopic visualization, a metal wire was sutured to the iliopsoas and wires were also embedded into grooves on the outer surface of the liner and the inner head. All retrievals showed evidence of femoral neck contact. The cadaver experiments showed that liner motion was impeded by impingement with the iliopsoas tendon in low flexion angles. When observing the hip during maximum hyperextension, 0°, 15°, and 30° of flexion, there was noticeable tenting of the iliopsoas caused by impingement with the liner. Liner rim deformation resulting from contact with the femoral neck likely begins during early in vivo function. The presence of deformation is indicative of a mechanism inhibiting mobility of the liner. The cadaver studies showed that liner motion could be impeded because of its impingement with the iliopsoas. Such soft tissue impingement may be one mechanism by which liner motion is routinely inhibited, which can result in load transfer from the neck to the rim. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Cannula Versus Sharp Needle for Placement of Soft Tissue Fillers: An Observational Cadaver Study.

    Science.gov (United States)

    van Loghem, Jani A J; Humzah, Dalvi; Kerscher, Martina

    2017-12-13

    Soft-tissue fillers have become important products for facial rejuvenation. Deep fat compartments and facial bones lose volume during the natural aging process. For the most natural-looking results, deep volumetric injections at strategic sites are therefore preferred. Supraperiosteal placement is performed with a sharp needle or a non-traumatic cannula. The primary objective was to determine whether there is a difference in precision between supraperiosteal placement with a sharp needle compared with a non-traumatic cannula in cadaver specimens. A secondary objective was to analyze the safety profiles of both injection techniques. Cadaver heads were injected with dye material and soft-tissue fillers at multiple aesthetic facial sites on the supraperiosteum and subsequently dissected for observation of dye and filler placement. The non-traumatic cannula technique resulted in product being confined to the deep anatomic layers. In contrast, with the sharp needle technique, material was placed in multiple anatomic layers, from the periosteum to more superficial skin layers. For both techniques results were consistent for all facial sites. Although direct extrapolation from cadavers to the in vivo situation cannot be made, cannulae showed more precision in placement of product. With the sharp needle, the material was injected on the periosteum, and then migrated in a retrograde direction along the trajectory of the needle path, ending up in multiple anatomic layers. The sharp needle technique also showed a higher complication risk with intra-arterial injection occurring, even though the needle tip was positioned on the periosteum and the product was injected with the needle in constant contact with the periosteum. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  7. The Living Dead: Bacterial Community Structure of a Cadaver at the Onset and End of the Bloat Stage of Decomposition

    OpenAIRE

    Hyde, Embriette R.; Haarmann, Daniel P.; Lynne, Aaron M.; Bucheli, Sibyl R.; Petrosino, Joseph F.

    2013-01-01

    Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphono...

  8. Evaluation of hands-on seminar for reduced port surgery using fresh porcine cadaver model

    Directory of Open Access Journals (Sweden)

    Saseem Poudel

    2016-01-01

    Full Text Available Background: The use of various biological and non-biological simulators is playing an important role in training modern surgeons with laparoscopic skills. However, there have been few reports of the use of a fresh porcine cadaver model for training in laparoscopic surgical skills. The purpose of this study was to report on a surgical training seminar on reduced port surgery using a fresh cadaver porcine model and to assess its feasibility and efficacy. Materials and Methods: The hands-on seminar had 10 fresh porcine cadaver models and two dry boxes. Each table was provided with a unique access port and devices used in reduced port surgery. Each group of 2 surgeons spent 30 min at each station, performing different tasks assisted by the instructor. The questionnaire survey was done immediately after the seminar and 8 months after the seminar. Results: All the tasks were completed as planned. Both instructors and participants were highly satisfied with the seminar. There was a concern about the time allocated for the seminar. In the post-seminar survey, the participants felt that the number of reduced port surgeries performed by them had increased. Conclusion: The fresh cadaver porcine model requires no special animal facility and can be used for training in laparoscopic procedures.

  9. Evaluation of hands-on seminar for reduced port surgery using fresh porcine cadaver model.

    Science.gov (United States)

    Poudel, Saseem; Kurashima, Yo; Shichinohe, Toshiaki; Kitashiro, Shuji; Kanehira, Eiji; Hirano, Satoshi

    2016-01-01

    The use of various biological and non-biological simulators is playing an important role in training modern surgeons with laparoscopic skills. However, there have been few reports of the use of a fresh porcine cadaver model for training in laparoscopic surgical skills. The purpose of this study was to report on a surgical training seminar on reduced port surgery using a fresh cadaver porcine model and to assess its feasibility and efficacy. The hands-on seminar had 10 fresh porcine cadaver models and two dry boxes. Each table was provided with a unique access port and devices used in reduced port surgery. Each group of 2 surgeons spent 30 min at each station, performing different tasks assisted by the instructor. The questionnaire survey was done immediately after the seminar and 8 months after the seminar. All the tasks were completed as planned. Both instructors and participants were highly satisfied with the seminar. There was a concern about the time allocated for the seminar. In the post-seminar survey, the participants felt that the number of reduced port surgeries performed by them had increased. The fresh cadaver porcine model requires no special animal facility and can be used for training in laparoscopic procedures.

  10. Cementless anatomical prosthesis for the treatment of 3-part and 4-part proximal humerus fractures: cadaver study and prospective clinical study with minimum 2 years followup

    Directory of Open Access Journals (Sweden)

    Obert Laurent

    2016-01-01

    Full Text Available Introduction: The purpose of this study was to evaluate the functional and radiological outcomes of a cementless, trauma-specific locked stem for 3- and 4-part proximal humeral fractures. Materials and methods: This study consisted of two parts: a cadaver study with 22 shoulders and a multicenter prospective clinical study of 23 fracture patients evaluated at least 2 years after treatment. In the cadaver study, the locked stem (HumelockTM, FX Solutions and its instrumentation were evaluated. In the clinical study, five senior surgeons at four different hospitals performed the surgical procedures. An independent surgeon evaluated the patients using clinical (Constant score, QuickDASH and radiological (X-rays, CT scans outcome measures. Results: The cadaver study allowed us to validate the height landmarks relative to the pectoralis major tendon. In the clinical study, at the review, abduction was 95° (60–160, forward flexion was 108° (70–160, external rotation (elbow at body was 34° (0–55, the QuickDASH was 31 (4.5–59, the overall Constant score was 54 (27–75, and the weighted Constant score was 76 (31.5–109. Discussion: This preliminary study of hemiarthroplasty (HA with a locked stem found results that were at least equivalent to published series. As all patients had at least a 2-year follow-up, integration of the locked stem did not cause any specific complications. These results suggest that it is possible to avoid using cement when hemiarthroplasty is performed for the humeral stem. This implant makes height adjustment and transosseous suturing of the tuberosities more reproducible.

  11. Practical guidelines for setting up neurosurgery skills training cadaver laboratory in India.

    Science.gov (United States)

    Suri, Ashish; Roy, Tara Sankar; Lalwani, Sanjeev; Deo, Rama Chandra; Tripathi, Manjul; Dhingra, Renu; Bhardwaj, Daya Nand; Sharma, Bhawani Shankar

    2014-01-01

    Though the necessity of cadaver dissection is felt by the medical fraternity, and described as early as 600 BC, in India, there are no practical guidelines available in the world literature for setting up a basic cadaver dissection laboratory for neurosurgery skills training. Hands-on dissection practice on microscopic and endoscopic procedures is essential in technologically demanding modern neurosurgery training where ethical issues, cost constraints, medico-legal pitfalls, and resident duty time restrictions have resulted in lesser opportunities to learn. Collaboration of anatomy, forensic medicine, and neurosurgery is essential for development of a workflow of cadaver procurement, preservation, storage, dissection, and disposal along with setting up the guidelines for ethical and legal concerns.

  12. Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study.

    Science.gov (United States)

    Gutowski, Christina J; Darvish, Kurosh; Ilyas, Asif M; Jones, Christopher M

    2017-02-01

    The interosseous ligament (IOL) is known to be an important longitudinal stabilizer of the forearm. We hypothesize that it may also contribute to transverse stability, with pronosupination tensioning of the radius relative to the ulna. Therefore, when injured, we predict the interosseous space should widen in the transverse plane, enough to be appreciable on plain radiographs. A measurable difference in interosseous space, comparing an injured with an uninjured forearm, can potentially be of diagnostic and clinical value. Ten fresh-frozen cadaver arms (from 5 individuals) were radiographed in 6 different positions of forearm supination, first in an uninjured state and then with the IOL sectioned, both partially (central band only) and completely. The transverse interosseous distance was measured on radiographs using edge detection software and compared using analysis of variance and contrast analysis. The maximum range of pronosupination was also compared before and after injury, using a paired t test. Average maximum supination increased from 84° to 106°, and pronation from 69° to 84°, after the IOL was sectioned completely. Sectioning of the IOL led to a statistically significant increase in the interosseous distance, a minimum of 2 mm, in all but one forearm position. The IOL of the forearm plays an important role in providing transverse stability to the radius and ulna. When the IOL is sectioned, the forearm exhibits increased pronosupination range of motion. Radiographs of bilateral forearms taken in identical rotational position can reliably differentiate between an intact and torn IOL in cadavers. The IOL's stabilizing role during forearm rotation suggests a novel strategy for diagnosing forearm IOL injury using comparative radiographic measurements. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  13. Learning Anatomy through Thiel- vs. Formalin-Embalmed Cadavers: Student Perceptions of Embalming Methods and Effect on Functional Anatomy Knowledge

    Science.gov (United States)

    Kennel, Larissa; Martin, David M. A.; Shaw, Hannah; Wilkinson, Tracey

    2018-01-01

    Thiel-embalmed cadavers, which have been adopted for use in anatomy teaching in relatively few universities, show greater flexibility and color retention compared to formalin-embalmed cadavers, properties which might be considered advantageous for anatomy teaching. This study aimed to investigate student attitudes toward the dissection experience…

  14. Electric cadavers, 'metiphor,' and other medical software marvels.

    Science.gov (United States)

    Weiss, M

    1991-04-01

    "Grateful Med," "Fluids," "Metiphor," virtual reality, and electric cadavers are just some of the programs and buzzwords in the futuristic world of medical software affecting many areas of health care.

  15. Can the gracilis be used to replace the anterior cruciate ligament in the knee? A cadaver study.

    Science.gov (United States)

    Cavaignac, Etienne; Pailhé, Regis; Murgier, Jérôme; Reina, Nicolas; Lauwers, Frederic; Chiron, Philippe

    2014-12-01

    The purpose of this study was to evaluate whether a four-strand gracilis-only graft can be used in anterior cruciate ligament (ACL) reconstruction. Cadaver study. This study involved 16 cadaver knees. The length and diameter of the native ACL were measured in each one. The same measurements were performed on a four-strand graft of the gracilis only, the semitendinosus only and both tendons. Student's t-test was used to compare the various conditions. The average diameter of the G4 construct was 0.07 mm greater (1%) than the native ACL (p=0.044). The average cross-sectional area of the G4 construct was 1.2 mm(2) greater (3.9%) than the native ACL (p=0.049). The G4 was on average 38.9 mm longer than the intra-articular portion of the ACL (p<0.001). A four-strand gracilis construct meets the anatomical specifications for use as an ACL reconstruction graft. By using the gracilis only, the morbidity associated with harvesting the gracilis and semitendinosus tendons should be reduced. Further studies must be performed to compare the biomechanical properties of this graft with other graft types and also to evaluate how this four-strand gracilis graft behaves in a clinical setting. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. The Living Dead: Bacterial Community Structure of a Cadaver at the Onset and End of the Bloat Stage of Decomposition

    Science.gov (United States)

    Hyde, Embriette R.; Haarmann, Daniel P.; Lynne, Aaron M.; Bucheli, Sibyl R.; Petrosino, Joseph F.

    2013-01-01

    Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphonomy and readily attributed to microbial physiology, was targeted. Each cadaver was sampled at two time points, at the onset and end of the bloat stage, from various body sites including internal locations. Bacterial samples were analyzed by pyrosequencing of the 16S rRNA gene. Our data show a shift from aerobic bacteria to anaerobic bacteria in all body sites sampled and demonstrate variation in community structure between bodies, between sample sites within a body, and between initial and end points of the bloat stage within a sample site. These data are best not viewed as points of comparison but rather additive data sets. While some species recovered are the same as those observed in culture-based studies, many are novel. Our results are preliminary and add to a larger emerging data set; a more comprehensive study is needed to further dissect the role of bacteria in human decomposition. PMID:24204941

  17. The living dead: bacterial community structure of a cadaver at the onset and end of the bloat stage of decomposition.

    Science.gov (United States)

    Hyde, Embriette R; Haarmann, Daniel P; Lynne, Aaron M; Bucheli, Sibyl R; Petrosino, Joseph F

    2013-01-01

    Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphonomy and readily attributed to microbial physiology, was targeted. Each cadaver was sampled at two time points, at the onset and end of the bloat stage, from various body sites including internal locations. Bacterial samples were analyzed by pyrosequencing of the 16S rRNA gene. Our data show a shift from aerobic bacteria to anaerobic bacteria in all body sites sampled and demonstrate variation in community structure between bodies, between sample sites within a body, and between initial and end points of the bloat stage within a sample site. These data are best not viewed as points of comparison but rather additive data sets. While some species recovered are the same as those observed in culture-based studies, many are novel. Our results are preliminary and add to a larger emerging data set; a more comprehensive study is needed to further dissect the role of bacteria in human decomposition.

  18. The living dead: bacterial community structure of a cadaver at the onset and end of the bloat stage of decomposition.

    Directory of Open Access Journals (Sweden)

    Embriette R Hyde

    Full Text Available Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphonomy and readily attributed to microbial physiology, was targeted. Each cadaver was sampled at two time points, at the onset and end of the bloat stage, from various body sites including internal locations. Bacterial samples were analyzed by pyrosequencing of the 16S rRNA gene. Our data show a shift from aerobic bacteria to anaerobic bacteria in all body sites sampled and demonstrate variation in community structure between bodies, between sample sites within a body, and between initial and end points of the bloat stage within a sample site. These data are best not viewed as points of comparison but rather additive data sets. While some species recovered are the same as those observed in culture-based studies, many are novel. Our results are preliminary and add to a larger emerging data set; a more comprehensive study is needed to further dissect the role of bacteria in human decomposition.

  19. Response of forest soil euglyphid testate amoebae (Rhizaria: Cercozoa) to pig cadavers assessed by high-throughput sequencing.

    Science.gov (United States)

    Seppey, Christophe V W; Fournier, Bertrand; Szelecz, Ildikò; Singer, David; Mitchell, Edward A D; Lara, Enrique

    2016-03-01

    Decomposing cadavers modify the soil environment, but the effect on soil organisms and especially on soil protists is still poorly documented. We conducted a 35-month experiment in a deciduous forest where soil samples were taken under pig cadavers, control plots and fake pigs (bags of similar volume as the pigs). We extracted total soil DNA, amplified the SSU ribosomal RNA (rRNA) gene V9 region and sequenced it by Illumina technology and analysed the data for euglyphid testate amoebae (Rhizaria: Euglyphida), a common group of protozoa known to respond to micro-environmental changes. We found 51 euglyphid operational taxonomic units (OTUs), 45 of which did not match any known sequence. Most OTUs decreased in abundance underneath cadavers between days 0 and 309, but some responded positively after a time lag. We sequenced the full-length SSU rRNA gene of two common OTUs that responded positively to cadavers; a phylogenetic analysis showed that they did not belong to any known euglyphid family. This study confirmed the existence of an unknown diversity of euglyphids and that they react to cadavers. Results suggest that metabarcoding of soil euglyphids could be used as a forensic tool to estimate the post-mortem interval (PMI) particularly for long-term (>2 months) PMI, for which no reliable tool exists.

  20. Panceratic Complications of Mustard Gas Exposure: A Study on Cadavers

    Directory of Open Access Journals (Sweden)

    Amir Farshid Fayyaz

    2015-06-01

    Full Text Available Background: Sulfur mustard is one of the chemical warfare gases that has been known as a vesicant or blistering agents. It is a chemical alkylating compound agent that can be frequently absorbed through skin, respiratory system, genital tract, and ocular system. This study was done to pathologically analyze the microscopic pancreatic lesions in cadavers. Methods: This case series study was performed during 2007 to 2012 in Legal Medicine Organization. Exposure was confirmed by the written reports of the field hospitals, based on acute presentation of eye, skin and pulmonary symptoms of the exposure. Results: Pancreatic autopsy findings were chronic inflammation, fibrosis and duct ectasia; acinar atrophy was also seen in 4 cases. All 4 cases had chronic pancreatic disease with abdominal pain, steatorrhea and weight loss that was confirmed by sonography. CT scan and Endoscopic Retrograde Cholangio-Pancreatography (ERCP have also demonstrated the chronic pancreatitis. Conclusion: According to the chronic progressive lesions caused by mustard gas exposure such as pulmonary lesions and also its high mortality rate, suitable programming for protection of the mustard gas exposed people in chemical factories is necessary.

  1. Studies on the metabolism of five model drugs by fungi colonizing cadavers using LC-ESI-MS/MS and GC-MS analysis.

    Science.gov (United States)

    Martínez-Ramírez, Jorge A; Voigt, Kerstin; Peters, Frank T

    2012-09-01

    It is well-known that cadavers may be colonized by microorganisms, but there is limited information if or to what extent these microbes are capable of metabolizing drugs or poisons, changing the concentrations and metabolic pattern of such compounds in postmortem samples. The aim of the present study was to develop a fungal biotransformation system as an in vitro model to investigate potential postmortem metabolism by fungi. Five model drugs (amitriptyline, metoprolol, mirtazapine, promethazine, and zolpidem) were each incubated with five model fungi known to colonize cadavers (Absidia repens, Aspergillus repens, Aspergillus terreus, Gliocladium viride, and Mortierella polycephala) and with Cunninghamella elegans (positive control). Incubations were performed in Sabouraud medium at 25 °C for 5 days. After centrifugation, a part of the supernatants was analyzed by liquid chromatography-tandem mass spectrometry with product ion scanning. Another part was analyzed by full scan gas chromatography-mass spectrometry after extraction and derivatization. All model drugs were metabolized by the control fungus resulting in two (metoprolol) to ten (amitriptyline) metabolites. Of the model fungi, only Abs. repens and M. polycephala metabolized the model drugs: amitriptyline was metabolized to six and five, metoprolol to two and two, mirtazapine to five and three, promethazine to six and nine, and zolpidem to three and four metabolites, respectively. The main metabolic reactions were demethylation, oxidation, and hydroxylation. The presented in vitro model is applicable to studying drug metabolism by fungi colonizing cadavers.

  2. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: An experimental cadaver study.

    Science.gov (United States)

    Scheele, Christian; Pietschmann, Matthias F; Schröder, Christian; Grupp, Thomas; Holderied, Melanie; Jansson, Volmar; Müller, Peter E

    2017-03-01

    Unicompartmental total knee arthroplasty (UKA) is a well-established treatment option for unicondylar osteoarthritis, and generally leads to better functional results than tricompartimental total knee arthroplasty (TKA). However, revision rates of UKAs are reported as being higher; a major reason for this is aseptic loosening of the tibial component due to implant-cement-bone interface fatigue. The objective of this study was to determine the effects of trabecular bone preparation, prior to implantation of tibial UKAs, on morphological and biomechanical outcomes in a cadaver study. Cemented UKAs were performed in 18 human cadaver knees after the bone bed was cleaned using pulsed lavage (Group A), conventional brush (Group B) or no cleaning at all (Group C, control). Morphologic cement penetration and primary stability were measured. The area proportion under the tibial component without visible cement penetration was significantly higher in Group C (21.9%, SD 11.9) than in both Group A (7.1%, SD 5.8), and Group B (6.5%, SD 4.2) (P=0.007). The overall cement penetration depth did not differ between groups. However, in the posterior part, cement penetration depth was significantly higher in Group B (1.9mm, SD 0.3) than in both Group A (1.3mm, SD 0.3) and Group C (1.4mm, SD 0.3) (P=0.015). The mode of preparation did not show a substantial effect on primary stability tested under dynamic compression-shear test conditions (P=0.910). Bone preparation significantly enhances cement interdigitation. The application of a brush shows similar results compared with the application of pulsed lavage. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Free manual of cadaver dissection modifiable by other anatomists.

    Science.gov (United States)

    Chung, Beom Sun; Chung, Min Suk

    2015-06-01

    Even in the rapidly changing field of cadaver dissection, published guide books still play an important role in the anatomy lab. However, commercial manuals with lengthy volumes and inflexible copyrights have several limitations which can be complemented by open-source manuals. Recently, the authors have manufactured and distributed a free electronic dissection manual (anatomy.co.kr), where descriptions are written concisely and images are drawn schematically. Moreover, simplified signs are employed to represent the cadaver viewing angles and manner of dissection. Based on the original files of this manual, other anatomists can revise and utilize the descriptions and figures. We expect many updated versions of our manual to be shared between students all over the world.

  4. Optimizing the Use of Cadavers by Integrating Pathology during Anatomy Dissection

    Science.gov (United States)

    Geldenhuys, Elsje-Márie; Burger, Elsie Helena; van Helden, Paul David; Mole, Calvin Gerald; Kotzé, Sanet Henriët

    2016-01-01

    An accurate knowledge of anatomy, especially natural variation within individuals, is of vital clinical importance. Cadaver dissection during anatomical training may be a valuable introduction to pathology for undergraduate students, which can contribute greatly to a successful medical career. The purpose of this study was to determine the extent…

  5. Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study.

    Science.gov (United States)

    García-Sanz, Verónica; Bellot-Arcís, Carlos; Hernández, Virginia; Serrano-Sánchez, Pedro; Guarinos, Juan; Paredes-Gallardo, Vanessa

    2017-09-20

    The accuracy of Cone-Beam Computed Tomography (CBCT) on linear and volumetric measurements on condyles has only been assessed on dry skulls. The aim of this study was to evaluate the reliability and accuracy of linear and volumetric measurements of mandibular condyles in the presence of soft tissues using CBCT. Six embalmed cadaver heads were used. CBCT scans were taken, followed by the extraction of the condyles. The water displacement technique was used to calculate the volumes of the condyles and three linear measurements were made using a digital caliper, these measurements serving as the gold standard. Surface models of the condyles were obtained using a 3D scanner, and superimposed onto the CBCT images. Condyles were isolated on the CBCT render volume using the surface models as reference and volumes were measured. Linear measurements were made on CBCT slices. The CBCT method was found to be reliable for both volumetric and linear measurements (CV  0.90). Highly accurate values were obtained for the three linear measurements and volume. CBCT is a reliable and accurate method for taking volumetric and linear measurements on mandibular condyles in the presence of soft tissue, and so a valid tool for clinical diagnosis.

  6. Biomechanical Analysis of Human Abdominal Impact Responses and Injuries through Finite Element Simulations of a Full Human Body Model.

    Science.gov (United States)

    Ruan, Jesse S; El-Jawahri, Raed; Barbat, Saeed; Prasad, Priya

    2005-11-01

    Human abdominal response and injury in blunt impacts was investigated through finite element simulations of cadaver tests using a full human body model of an average-sized adult male. The model was validated at various impact speeds by comparing model responses with available experimental cadaver test data in pendulum side impacts and frontal rigid bar impacts from various sources. Results of various abdominal impact simulations are presented in this paper. Model-predicted abdominal dynamic responses such as force-time and force-deflection characteristics, and injury severities, measured by organ pressures, for the simulated impact conditions are presented. Quantitative results such as impact forces, abdominal deflections, internal organ stresses have shown that the abdomen responded differently to left and right side impacts, especially in low speed impact. Results also indicated that the model exhibited speed sensitive response characteristics and the compressibility of the abdomen significantly influenced the overall impact response in the simulated impact conditions. This study demonstrates that the development of a validated finite element human body model can be useful for abdominal injury assessment. Internal organ injuries, which are difficult to detect in experimental studies with human cadavers due to the difficulty of instrumentation, may be more easily identified with a validated finite element model through stress-strain analysis.

  7. Acromioclavicular joint dislocations: radiological correlation between Rockwood classification system and injury patterns in human cadaver species.

    Science.gov (United States)

    Eschler, Anica; Rösler, Klaus; Rotter, Robert; Gradl, Georg; Mittlmeier, Thomas; Gierer, Philip

    2014-09-01

    The classification system of Rockwood and Young is a commonly used classification for acromioclavicular joint separations subdividing types I-VI. This classification hypothesizes specific lesions to anatomical structures (acromioclavicular and coracoclavicular ligaments, capsule, attached muscles) leading to the injury. In recent literature, our understanding for anatomical correlates leading to the radiological-based Rockwood classification is questioned. The goal of this experimental-based investigation was to approve the correlation between the anatomical injury pattern and the Rockwood classification. In four human cadavers (seven shoulders), the acromioclavicular and coracoclavicular ligaments were transected stepwise. Radiological correlates were recorded (Zanca view) with 15-kg longitudinal tension applied at the wrist. The resulting acromio- and coracoclavicular distances were measured. Radiographs after acromioclavicular ligament transection showed joint space enlargement (8.6 ± 0.3 vs. 3.1 ± 0.5 mm, p acromioclavicular joint space width increased to 16.7 ± 2.7 vs. 8.6 ± 0.3 mm, p acromioclavicular joint lesions higher than Rockwood type I and II. The clinical consequence for reconstruction of low-grade injuries might be a solely surgical approach for the acromioclavicular ligaments or conservative treatment. High-grade injuries were always based on additional structural damage to the coracoclavicular ligaments. Rockwood type V lesions occurred while muscle attachments were intact.

  8. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    Science.gov (United States)

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (pcadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical

  9. Comparison of in vivo vs. frozen vs. Thiel cadaver specimens in visualisation of anatomical structures of the ankle on proton density Magnetic Resonance Imaging (MRI) through a visual grading analysis (VGA) study

    International Nuclear Information System (INIS)

    Zarb, F.; McNulty, J.; Gatt, A.; Formosa, C.; Chockalingam, N.; Evanoff, M.G.; Rainford, L.

    2017-01-01

    Purpose: The use of cadavers for medical education purposes and for radiology research methodologies which involve subjective image quality evaluation of anatomical criteria is well documented. The aim of this study was to quantify the impact of cadaver tissue preservation in producing MR images that are representative of living tissue by comparing the visualisation of anatomical structures of the ankle obtained from live and cadaver (fresh frozen and Thiel embalmed) specimens through a visual grading analysis (VGA) study. Methods: A VGA study was conducted on an image data set consisting of 4 coronal proton density weighted (PDw) sequences obtained from ankles of a live patient and those of a cadaveric specimen, of which the right ankle was frozen and the left Thiel embalmed. Results: Comparison of the image quality scores obtained from: the live patient vs. the Thiel specimen indicate a significant difference (p ≤ 0.05) between the scores in favour of the Thiel specimen; between the live patient vs. the frozen specimen indicate a significant difference (p ≤ 0.05) in favour of the frozen specimen and between the frozen vs. the Thiel specimen indicate a significant difference (p ≤ 0.05) in favour of the Thiel specimen. Conclusions: The advantages of the use of cadavers (frozen or Thiel embalmed) has been shown to also apply for use with proton density (PD) MR imaging. The preservation of cadavers especially using Thiel is a suitable alternative for MRI optimisation and protocol development purposes. - Highlights: • Thiel preservation: a better alternative compared to frozen methods for MR image analysis. • VGA demonstrated an efficient research study design for the investigation of embalming methods. • Thiel embalmed cadavers: an acceptable alternative from patients for MR imaging optimisation. • Additional MR sequences and increased sample sizes are recommended for further investigation.

  10. Porcine cadaver organ or virtual-reality simulation training for laparoscopic cholecystectomy: a randomized, controlled trial

    NARCIS (Netherlands)

    van Bruwaene, Siska; Schijven, Marlies P.; Napolitano, Daniel; de Win, Gunter; Miserez, Marc

    2015-01-01

    As conventional laparoscopic procedural training requires live animals or cadaver organs, virtual simulation seems an attractive alternative. Therefore, we compared the transfer of training for the laparoscopic cholecystectomy from porcine cadaver organs vs virtual simulation to surgery in a live

  11. Quantifying surgical access in eyebrow craniotomy with and without orbital bar removal: cadaver and surgical phantom studies.

    Science.gov (United States)

    Zador, Zsolt; Coope, David J; Gnanalingham, Kanna; Lawton, Michael T

    2014-04-01

    Eyebrow craniotomy is a recently described minimally invasive approach for tackling primarily pathology of the anterior skull base. The removal of the orbital bar may further expand the surgical corridor of this exposure, but the extent of benefit is poorly quantified. We assessed the effect of orbital bar removal with regards to surgical access in the eyebrow craniotomy using classic morphometric measurements in cadaver heads. Using surgical phantoms and neuronavigation, we also measured the 'working volume', a new parameter for characterising the volume of surgical access in these approaches. Silicon injected cadaver heads (n = 5) were used for morphometric analysis of the eyebrow craniotomy with and without orbital bar removal. Working depths and 'working areas' of surgical access were measured as defined by key anatomical landmarks. The eyebrow craniotomy with or without orbital bar removal was also simulated using surgical phantoms (n = 3, 90-120 points per trial), calibrated against a frameless neuronavigation system. Working volume was derived from reference coordinates recorded along the anatomical borders of the eyebrow craniotomy using the "α-shape algorithm" in R statistics. In cadaver heads, eyebrow craniotomy with removal of the orbital bar reduced the working depth to the ipsilateral anterior clinoid process (42 ± 2 versus 33 ± 3 mm; p < 0.05), but the working areas as defined by deep neurovascular and bony landmarks was statistically unchanged (total working areas of 418 ± 80 cm(2) versus 334 ± 48 cm(2); p = 0.4). In surgical phantom studies, however, working-volume for the simulated eyebrow craniotomies was increased with orbital bar removal (16 ± 1 cm(3) versus 21 ± 1 cm(3); p < 0.01). In laboratory studies, orbital bar removal in eyebrow craniotomy provides a modest reduction in working depth and increase in the working volume. But this must be weighed up against the added morbidity of the

  12. Diagnosis of Complex Pulley Ruptures Using Ultrasound in Cadaver Models.

    Science.gov (United States)

    Schöffl, Isabelle; Hugel, Arnica; Schöffl, Volker; Rascher, Wolfgang; Jüngert, Jörg

    2017-03-01

    Pulley ruptures are common in climbing athletes. The purposes of this study were to determine the specific positioning of each pulley with regards to the joint, and to evaluate the ultrasound diagnostics of various pulley rupture combinations. For this, 34 cadaver fingers were analyzed via ultrasound, the results of which were compared to anatomic measurements. Different pulley ruptures were then simulated and evaluated using ultrasound in standardized dynamic forced flexion. Visualization of the A2 and A4 pulleys was achieved 100% of the time, while the A3 pulley was visible in 74% of cases. Similarly, injuries to the A2 and A4 pulleys were readily observable, while A3 pulley injuries were more challenging to identify (sensitivity of 0.2 for singular A3 pulley, 0.5 for A2/A4 pulley and 0.33 for A3/A4 pulley ruptures). Receiver operating characteristic analysis was used to evaluate the optimal tendon-bone distance for pulley rupture diagnosis, a threshold which was determined to be 1.9 mm for A2 pulley ruptures and 1.85 for A4 pulley ruptures. This study was the first to carry out a cadaver ultrasound examination of a wide variety of pulley ruptures. Ultrasound is a highly accurate tool for visualizing the A2 and A4 pulleys in a cadaver model. This method of pathology diagnosis was determined to be suitable for injuries to the A2 and A4 pulleys, but inadequate for A3 pulley injuries. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Exploring metal artifact reduction using dual-energy CT with pre-metal and post-metal implant cadaver comparison: are implant specific protocols needed?

    NARCIS (Netherlands)

    Wellenberg, Ruud H. H.; Donders, Johanna C. E.; Kloen, Peter; Beenen, Ludo F. M.; Kleipool, Roeland P.; Maas, Mario; Streekstra, Geert J.

    2017-01-01

    To quantify and optimize metal artifact reduction using virtual monochromatic dual-energy CT for different metal implants compared to non-metal reference scans. Dual-energy CT scans of a pair of human cadaver limbs were acquired before and after implanting a titanium tibia plate, a stainless-steel

  14. A comparison of a traditional endotracheal tube versus ETView SL in endotracheal intubation during different emergency conditions: A randomized, crossover cadaver trial.

    Science.gov (United States)

    Truszewski, Zenon; Krajewski, Paweł; Fudalej, Marcin; Smereka, Jacek; Frass, Michael; Robak, Oliver; Nguyen, Bianka; Ruetzler, Kurt; Szarpak, Lukasz

    2016-11-01

    Airway management is a crucial skill essential to paramedics and personnel working in Emergency Medical Services and Emergency Departments: Lack of practice, a difficult airway, or a trauma situation may limit the ability of paramedics to perform direct laryngoscopy during cardiopulmonary resuscitation. Videoscope devices are alternatives for airway management in these situations. The ETView VivaSight SL (ETView; ETView Ltd., Misgav, Israel) is a new, single-lumen airway tube with an integrated high-resolution imaging camera. To assess if the ETView VivaSight SL can be a superior alternative to a standard endotracheal tube for intubation in an adult cadaver model, both during and without simulated CPR. ETView VivaSight SL tube was investigated via an interventional, randomized, crossover, cadaver study. A total of 52 paramedics participated in the intubation of human cadavers in three different scenarios: a normal airway at rest without concomitant chest compression (CC) (scenario A), a normal airway with uninterrupted CC (scenario B) and manual in-line stabilization (scenario C). Time and rate of success for intubation, the glottic view scale, and ease-of-use of ETView vs. sETT intubation were assessed for each emergency scenario. The median time to intubation using ETView vs. sETT was compared for each of the aforementioned scenarios. For scenario A, time to first ventilation was achieved fastest for ETView, 19.5 [IQR, 16.5-22] sec, when compared to that of sETT at 21.5 [IQR, 20-25] sec (p = .013). In scenario B, the time for intubation using ETView was 21 [IQR, 18.5-24.5] sec (p cadavers and the time to ventilation were improved with the ETView. The time to glottis view, tube insertion, and cuff block were all found to be shorter with the ETView. clinicaltrials.gov Identifier: NCT02733536.

  15. Progression of thanatophagy in cadaver brain and heart tissues

    Directory of Open Access Journals (Sweden)

    Gulnaz T. Javan

    2016-03-01

    Full Text Available Autophagy is an evolutionarily conserved catabolic process for maintaining cellular homeostasis during both normal and stress conditions. Metabolic reprogramming in tissues of dead bodies is inevitable due to chronic ischemia and nutrient deprivation, which are well-known features that stimulate autophagy. Currently, it is not fully elucidated whether postmortem autophagy, also known as thanatophagy, occurs in dead bodies is a function of the time of death. In this study, we tested the hypothesis that thanatophagy would increase in proportion to time elapsed since death for tissues collected from cadavers. Brain and heart tissue from corpses at different time intervals after death were analyzed by Western blot. Densitometry analysis demonstrated that thanatophagy occurred in a manner that was dependent on the time of death. The autophagy-associated proteins, LC3 II, p62, Beclin-1 and Atg7, increased in a time-dependent manner in heart tissues. A potent inducer of autophagy, BNIP3, decreased in the heart tissues as time of death increased, whereas the protein levels increased in brain tissues. However, there was no expression of BNIP3 at extended postmortem intervals in both brain and heart samples. Collectively, the present study demonstrates for the first time that thanatophagy occurs in brain and heart tissues of cadavers in a time-dependent manner. Further, our data suggest that cerebral thanatophagy may occur in a Beclin-1- independent manner. This unprecedented study provides potential insight into thanatophagy as a novel method for the estimation of the time of death in criminal investigationsAbstract: Autophagy is an evolutionarily conserved catabolic process for maintaining cellular homeostasis during both normal and stress conditions. Metabolic reprogramming in tissues of dead bodies is inevitable due to chronic ischemia and nutrient deprivation, which are well-known features that stimulate autophagy. Currently, it is not fully

  16. Laser-driven short-duration heating angioplasty: dilatation performance in cadaver atherosclerotic femoral arteries

    Science.gov (United States)

    Shimazaki, Natsumi; Naruse, Sho; Arai, Tsunenori; Imanishi, Nobuaki; Aiso, Sadakazu

    2013-03-01

    The purpose of this study was to investigate the artery dilatation performance of the short-duration heating balloon catheter in cadaver stenotic arteries. We designed a prototype short-duration heating balloon catheter that can heat artery media to around 60 °C in 15-25 s by a combination of laser-driven heat generation and continuous fluid irrigation in the balloon. We performed ex vivo short-duration heating dilatation in the cadaver atherosclerotic femoral arteries (initial percent diameter stenosis was 36-98%), with the maximum balloon temperature of 65+/-5 °C, laser irradiation duration of 25 s, and balloon dilatation pressure of 3.5 atm. The artery lumen configurations before and after the dilatations were assessed with a commercial IVUS system. After the short-duration heating dilatations, the percent diameter stenosis was reduced below 30% without any artery tears or dissections. We estimated that the artery media temperature was raised to around 60 °C in which plaque thickness was below 0.8 mm by a thermal conduction calculation. The estimated maximum temperature in artery adventitia and surrounding tissue was up to 45 °C. We found that the short-duration heating balloon could sufficiently dilate the cadaver stenotic arteries, without thermal injury in artery adventitia and surroundings.

  17. Anatomic variations found on dissection of depressor septi nasi muscles in cadavers.

    Science.gov (United States)

    Ebrahimi, Ali; Nejadsarvari, Nasrin; Motamedi, Mohammad Hosein Kalantar; Rezaee, Maryam; Koushki, Ehsan Shams

    2012-01-01

    To define variations of the depressor septi muscle in Iranians; to provide guidance for modification of this muscle during rhinoplasty in patients with an active muscle and short upper lip; and to correlate our findings with our clinical experience to develop the applied algorithms. This study was conducted by dissecting 82 depressor septi nasi muscles in 41 Iranian cadavers. Origin and insertion points of each muscle were studied. Three variations were found in muscle insertion points: periosteal, orbicularis oris, and floating. Forty-four percent of the muscles were inserted into the periosteum of the maxilla (n = 36); 39% of muscles were inserted into the orbicularis oris muscle (n = 32); and 17% were diminutive or floating (n = 14). Periosteal insertion was thicker and stronger than the other variations. In all cadavers, the origin of the muscle was medial crus of alar cartilage and caudal of the nasal septum. This cadaveric dissection showed that the percentage of depressor septi muscle insertions is not similar to that found in other surveys. In this study, periosteal insertion of the depressor septi muscle was the most common variation.

  18. Introduction of a fresh cadaver laboratory during the surgery clerkship improves emergency technical skills.

    Science.gov (United States)

    Nematollahi, Saman; Kaplan, Stephen J; Knapp, Christopher M; Ho, Hang; Alvarado, Jared; Viscusi, Rebecca; Adamas-Rappaport, William

    2015-08-01

    Student acquisition of technical skills during the clinical years of medical school has been steadily declining. To address this issue, the authors instituted a fresh cadaver-based Emergency Surgical Skills Laboratory (ESSL). Sixty-three medical students rotating through the third-year surgery clerkship participated in a 2-hour, fresh cadaver-based ESSL conducted during the first 2 days of the clerkship. The authors evaluated students utilizing both surgical skills and written examination before the ESSL and at 4 weeks post ESSL. Students demonstrated a mean improvement of 64% (±11) (P cadaver laboratory is an effective method to provide proficiency in emergency technical skills not acquired during the clinical years of medical school. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    DEFF Research Database (Denmark)

    Miles, James Edward; Jensen, Bente Rona; Kirpensteijn, Jolle

    2013-01-01

    . Animals-12 red fox (Vulpes vulpes) cadavers. Procedures-CT images of each hind limb in intact cadavers were obtained; at 1-week intervals, 3 reconstructions were performed that were based on 1 plane passing through the centers of the femoral head and medial condyle and parallel to the caudal femoral...

  20. Learning anatomy through Thiel- vs. formalin-embalmed cadavers: Student perceptions of embalming methods and effect on functional anatomy knowledge.

    Science.gov (United States)

    Kennel, Larissa; Martin, David M A; Shaw, Hannah; Wilkinson, Tracey

    2018-03-01

    Thiel-embalmed cadavers, which have been adopted for use in anatomy teaching in relatively few universities, show greater flexibility and color retention compared to formalin-embalmed cadavers, properties which might be considered advantageous for anatomy teaching. This study aimed to investigate student attitudes toward the dissection experience with Thiel- compared to formalin/ethanol-embalmed cadavers. It also aimed to determine if one embalming method is more advantageous in terms of learning functional anatomy through the comparison of student anterior forearm functional anatomy knowledge. Student opinions and functional anatomy knowledge were obtained through use of a questionnaire from students at two medical schools, one using Thiel-, and one using more traditional formalin/ethanol-embalmed cadavers. Both the Thiel group and the formalin group of students were surveyed shortly after completing an anterior forearm dissection session. Significant differences (P-values <0.01) in some attitudes were found toward the dissection experience between cohorts using Thiel- vs. formalin-embalmed cadavers. The Thiel group of students felt more confident about recognizing anatomy in the living individual, found it easier to identify and dissect anatomical structures, and indicated more active exploration of functional anatomy due to the retained flexibility of the cadaver. However, on testing, no significant difference in functional anatomy knowledge was found between the two cohorts. Overall, although Thiel embalming may provide an advantageous learning experience in some investigated areas, more research needs to be carried out, especially to establish whether student perception is based on reality, at least in terms of structure identification. Anat Sci Educ 11: 166-174. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  1. How to decrease the emotional impact of cadaver dissection in medical students

    Directory of Open Access Journals (Sweden)

    F Javadnia

    2009-03-01

    Full Text Available Background: Teaching anatomy is based on cadaver dissection. Working  with cadavers, whether through active dissection or by examination of prosected specimens, constitutes a potential stressor in medical  education.Purpose.To reduce the anxiety of the medical students by mentally preparing them before going to the dissection room.Methods: The questionnaires were distributed among 68 medical students. The pre-dissection questionnaire comprised questions related to demographic data and the first encounter with a cadaver. The students were randomly divided into experimental and control groups. The experimental group was prepared psychologically prior to dissection, but the control group entered the dissection room without any preparation. After the first dissection class, all students were surveyed by the second questionnaire  which surveyed physical and cognitive symptoms of anxiety, resulting from exposure to the dissection room at the first visit and six weeks later.Results: There was a significant difference (p<.05 in the rate of anxiety between experimental and control group in the initial visit. The difference in the rate of anxiety between the first exposure and six weeks later was significant in control group (p<.008, while it was not significant in the experimental group.Conclusion: The initial preparation could relatively reduce the rate of stress, so that the experimental group experienced less errs tonal effects during dissection compared to control group.Keyword: Emotional impact, cadaver dissection, medical students

  2. Autopsy experience with a radioactive cadaver

    International Nuclear Information System (INIS)

    Johnston, A.S.; Minarcik, J.; Rossi, R.; Pinsky, S.

    1979-01-01

    A patient who received a 200-mCi dose of 131 I for widespread carcinoma died 10 days after treatment with 50 mCi remaining in the cadaver. An autopsy was required. The radiation levels were sufficiently high that personnel radiation protection was needed. An autopsy procedure was designed that prevented ingestion of radioactivity by the pathologist and his assistants, prevented excessive exposure of any involved personnel, and prevented contamination of the autopsy room or other hospital space. (author)

  3. Lessons from dynamic cadaver and invasive bone pin studies: do we know how the foot really moves during gait?

    Directory of Open Access Journals (Sweden)

    Nester Christopher J

    2009-05-01

    Full Text Available Abstract Background This paper provides a summary of a Keynote lecture delivered at the 2009 Australasian Podiatry Conference. The aim of the paper is to review recent research that has adopted dynamic cadaver and invasive kinematics research approaches to better understand foot and ankle kinematics during gait. It is not intended to systematically cover all literature related to foot and ankle kinematics (such as research using surface mounted markers. Since the paper is based on a keynote presentation its focuses on the authors own experiences and work in the main, drawing on the work of others where appropriate Methods Two approaches to the problem of accessing and measuring the kinematics of individual anatomical structures in the foot have been taken, (i static and dynamic cadaver models, and (ii invasive in-vivo research. Cadaver models offer the advantage that there is complete access to all the tissues of the foot, but the cadaver must be manipulated and loaded in a manner which replicates how the foot would have performed when in-vivo. The key value of invasive in-vivo foot kinematics research is the validity of the description of foot kinematics, but the key difficulty is how generalisable this data is to the wider population. Results Through these techniques a great deal has been learnt. We better understand the valuable contribution mid and forefoot joints make to foot biomechanics, and how the ankle and subtalar joints can have almost comparable roles. Variation between people in foot kinematics is high and normal. This includes variation in how specific joints move and how combinations of joints move. The foot continues to demonstrate its flexibility in enabling us to get from A to B via a large number of different kinematic solutions. Conclusion Rather than continue to apply a poorly founded model of foot type whose basis is to make all feet meet criteria for the mechanical 'ideal' or 'normal' foot, we should embrace variation

  4. A novel semi-automatic snake robot for natural orifice transluminal endoscopic surgery: preclinical tests in animal and human cadaver models (with video).

    Science.gov (United States)

    Son, Jaebum; Cho, Chang Nho; Kim, Kwang Gi; Chang, Tae Young; Jung, Hyunchul; Kim, Sung Chun; Kim, Min-Tae; Yang, Nari; Kim, Tae-Yun; Sohn, Dae Kyung

    2015-06-01

    Natural orifice transluminal endoscopic surgery (NOTES) is an emerging surgical technique. We aimed to design, create, and evaluate a new semi-automatic snake robot for NOTES. The snake robot employs the characteristics of both a manual endoscope and a multi-segment snake robot. This robot is inserted and retracted manually, like a classical endoscope, while its shape is controlled using embedded robot technology. The feasibility of a prototype robot for NOTES was evaluated in animals and human cadavers. The transverse stiffness and maneuverability of the snake robot appeared satisfactory. It could be advanced through the anus as far as the peritoneal cavity without any injury to adjacent organs. Preclinical tests showed that the device could navigate the peritoneal cavity. The snake robot has advantages of high transverse force and intuitive control. This new robot may be clinically superior to conventional tools for transanal NOTES.

  5. Coupled Physical and Digital Cadaver Dissection Followed by a Visual Test Protocol Provides Insights into the Nature of Anatomical Knowledge and Its Evaluation

    Science.gov (United States)

    Hisley, Kenneth C.; Anderson, Larry D.; Smith, Stacy E.; Kavic, Stephen M.; Tracy, J. Kathleen

    2008-01-01

    This research effort compared and contrasted two conceptually different methods for the exploration of human anatomy in the first-year dissection laboratory by accomplished students: "physical" dissection using an embalmed cadaver and "digital" dissection using three-dimensional volume modeling of whole-body CT and MRI image sets acquired using…

  6. Development of a desiccated cadaver delivery system to apply entomopathogenic nematodes for control of soil pests

    Science.gov (United States)

    Pentomopathogenic nematodes may be more capable of controlling soil pests when they are harbored by desiccated cadavers. A small-scale system was developed from a modified crop seed planter to effectively deliver desiccated nematode-infected cadavers into the soil. The system mainly consists of a me...

  7. [Proposed difficult airway teaching methodology. Presentation of an interactive fresh frozen cadaver model].

    Science.gov (United States)

    Catalá Bauset, J C; de Andres Ibañez, J A; Valverde Navarro, A; Martinez Soriano, F

    2014-04-01

    The aim of this paper is to present a methodology based on the use of fresh-frozen cadavers for training in the management of the airway, and to evaluate the degree of satisfaction among learning physicians. About 6 fresh-frozen cadavers and 14 workstations were prepared where participants were trained in the different skills needed for airway management. The details of preparation of the cadavers are described. The level of satisfaction of the participant was determined using a Likert rating scale of 5 points, at each of the 14 stations, as well as the overall assessment and clinical usefulness of the course. The mean overall evaluation of the course and its usefulness was 4.75 and 4.9, out of 5, respectively. All parts of the course were rated above 4 out of 5. The high level of satisfaction of the course remained homogeneous in the 2 editions analysed. The overall satisfaction of the course was not finally and uniquely determined by any of its particular parts. The fresh cadaver model for training physicians in techniques of airway management is a proposal satisfactory to the participant, and with a realism that approaches the live patient. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  8. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR "DIE PUNCH" DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY.

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2012-01-01

    the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees.

  9. The relationship between cadaver, living and forensic stature: A review of current knowledge and a test using a sample of adult Portuguese males.

    Science.gov (United States)

    Cardoso, Hugo F V; Marinho, Luísa; Albanese, John

    2016-01-01

    The use of cadaver length and forensic stature as a proxy for living standing height has not been scrutinized in detail. In this paper we present a brief review of the current knowledge on the relationship between cadaver, living and forensic stature; assess the magnitude and nature of the differences between these three measures of stature; and investigate the potential impact of these differences in forensic contexts. The study uses a sample of 84 males who were autopsied in 2008 at the National Institute of Legal Medicine and Forensic Sciences (Porto, Portugal), where stature data were collected from three different sources: cadaver stature was obtained from the corpse prior to autopsy, living stature was obtained from military conscription records and forensic stature was obtained from national citizenship identification card records. Descriptive statistics, ANOVA and linear regression are used to analyze the data. The results show that cadaver stature is the highest measure, followed by forensic and by living stature, and the difference between cadaver and living stature is greater than expected (4.3cm). Results also show considerable individual variation in the differences between the three measures of stature and that differences decrease with stature, although only slightly. This study has shown that the difference between cadaver and living stature is greater than previously thought and suggests that previously reported correction factors are a minimum rather than a mean correction. Forensic stature is likely to be incorrectly estimated and can jeopardize identification if methods estimate living rather than forensic stature. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  11. Perception to Cadaver Dissection and Views on Anatomy as a ...

    African Journals Online (AJOL)

    However, literature on medical students' perceptions on cadaver dissection and their ... Bachelor of Medicine and Bachelor of Surgery at the new school of Medicine, Kenya ... training and counseling to make the experience better for students.

  12. Lengths and Positions of the Vermiform Appendix among Sudanese Cadavers

    Directory of Open Access Journals (Sweden)

    Ehab I. El-Amin

    2015-08-01

    Full Text Available Background/objective: The anatomy of vermiform appendix displays great variations in length and position between different populations. The reports relating these variations to a specific etiological factor are few. This study aims to describe the positions and lengths of vermiform appendix among Sudanese cadavers. Methods: This descriptive study was carried out in Omdurman Teaching Hospital Morgue and Omdurman Islamic University-Sudan. Sixty Sudanese cadavers (30 male and 30 female, were dissected in the period from June 2013 to June 2014. The positions and the lengths of vermiform appendix were measured in millimeters. The data was analyzed by SPSS version 20. Results: The cadavers’ age ranged between 20 to 80 years according to their medico-legal reports. Retrocaecal position was mainly observed in 60%, pelvic in 35%, post-ileal in 3.3%, and pre-ileal in 1.7%. The lengths of the appendix was found < 69 mm in 23.3%, 70-110 mm in 60%, and > 110 mm in 16.7%, also the study showed insignificant difference between the lengths and ages (p < 0.08, and between males and females (p = 0.23. Age was the influencing factor for the positions of vermiform appendixes (p = 0.04. Conclusion: The study showed that the commonest lengths of the appendix were 70-110 mm while the common position was retrocaecal regardless to age or gender. This data should be considered in surgical removal of the inflamed appendix.

  13. Harmonic scalpel versus flexible CO2 laser for tongue resection: A histopathological analysis of thermal damage in human cadavers

    Directory of Open Access Journals (Sweden)

    Wolf Tamir

    2011-08-01

    Full Text Available Abstract Background Monopolar cautery is the most commonly used surgical cutting and hemostatic tool for head and neck surgery. There are newer technologies that are being utilized with the goal of precise cutting, decreasing blood loss, reducing thermal damage, and allowing faster wound healing. Our study compares thermal damage caused by Harmonic scalpel and CO2 laser to cadaveric tongue. Methods Two fresh human cadaver heads were enrolled for the study. Oral tongue was exposed and incisions were made in the tongue akin to a tongue tumor resection using the harmonic scalpel and flexible C02 laser fiber at various settings recommended for surgery. The margins of resection were sampled, labeled, and sent for pathological analysis to assess depth of thermal damage calculated in millimeters. The pathologist was blinded to the surgical tool used. Control tongue tissue was also sent for comparison as a baseline for comparison. Results Three tongue samples were studied to assess depth of thermal damage by harmonic scalpel. The mean depth of thermal damage was 0.69 (range, 0.51 - 0.82. Five tongue samples were studied to assess depth of thermal damage by CO2 laser. The mean depth of thermal damage was 0.3 (range, 0.22 to 0.43. As expected, control samples showed 0 mm of thermal damage. There was a statistically significant difference between the depth of thermal injury to tongue resection margins by harmonic scalpel as compared to CO2 laser, (p = 0.003. Conclusion In a cadaveric model, flexible CO2 laser fiber causes less depth of thermal damage when compared with harmonic scalpel at settings utilized in our study. However, the relevance of this information in terms of wound healing, hemostasis, safety, cost-effectiveness, and surgical outcomes needs to be further studied in clinical settings.

  14. A Proposal for a Policy on the Ethical Care and Use of Cadavers and Their Tissues

    Science.gov (United States)

    Champney, Thomas H.

    2011-01-01

    Recent events have occurred that indicate the need for policies on the ethical care and use of cadavers and their tissues in the United States. At present, there are policies that address the procurement, handling and disposition of cadavers, but there are no national or society sponsored policies that clearly state the ethically appropriate use…

  15. Effectiveness of the Thoracic Pedicle Screw Placement Using the Virtual Surgical Training System: A Cadaver Study.

    Science.gov (United States)

    Hou, Yang; Lin, Yanping; Shi, Jiangang; Chen, Huajiang; Yuan, Wen

    2018-03-14

    The virtual simulation surgery has initially exhibited its promising potentials in neurosurgery training. To evaluate effectiveness of the Virtual Surgical Training System (VSTS) on novice residents placing thoracic pedicle screws in a cadaver study. A total of 10 inexperienced residents participated in this study and were randomly assigned to 2 groups. The group using VSTS to learn thoracic pedicle screw fixation was the simulation training (ST) group and the group receiving an introductory teaching session was the control group. Ten fresh adult spine specimens including 6 males and 4 females with a mean age of 58.5 yr (range: 33-72) were collected and randomly allocated to the 2 groups. After exposing anatomic structures of thoracic spine, the bilateral pedicle screw placement of T6-T12 was performed on each cadaver specimen. The postoperative computed tomography scan was performed on each spine specimen, and experienced observers independently reviewed the placement of the pedicle screws to assess the incidence of pedicle breach. The screw penetration rates of the ST group (7.14%) was significantly lower in comparison to the control group (30%, P < .05). Statistically significant difference in acceptable rates of screws also occurred between the ST (100%) and control (92.86%) group (P < .05). In addition, the average screw penetration distance in control group (2.37 mm ± 0.23 mm) was significantly greater than ST group (1.23 mm ± 0.56 mm, P < .05). The virtual reality surgical training of thoracic pedicle screw instrumentation effectively improves surgical performance of novice residents compared to those with traditional teaching method, and can help new beginners to master the surgical technique within shortest period of time.

  16. Crash-Resistant Crewseat Limit-Load Optimization through Dynamic Testing with Cadavers

    Science.gov (United States)

    1986-01-01

    shell on each surface of the verte- bral centrum is referred to as the bony end plate. Facing this bony end plate is a thin layer of hyaline cartilage ...most realistically, two vertebrae with the included intervertebral disc and hyaline cartilage . This section is referred to as the intervertebral joint...strengths of vertebrae from various studies ......... ... .......................... 5 2 Sumary of the test matrix for the cadaver test program . 33 3 Test

  17. The Histopathologic Reliability of Tissue Taken from Cadavers within the Gross Anatomy Laboratory

    Science.gov (United States)

    Rae, Guenevere; Newman, William P., III; McGoey, Robin; Donthamsetty, Supriya; Karpinski, Aryn C.; Green, Jeffrey

    2018-01-01

    The purpose of this study was to examine the histopathologic reliability of embalmed cadaveric tissue taken from the gross anatomy laboratory. Tissue samples from hearts, livers, lungs, and kidneys were collected after the medical students' dissection course was completed. All of the cadavers were embalmed in a formalin-based fixative solution.…

  18. Efficacy of orthotic immobilization of the unstable subaxial cervical spine of the elderly patient: investigation in a cadaver model

    Science.gov (United States)

    Bednar, Drew A.

    2004-01-01

    Objective To assess the efficacy of soft, semirigid and hard cervical collars to immobilize the neck in a destabilized cadaver model. Design This is a laboratory experiment. Setting The anatomy research lab of McMaster University. Patients None. Fresh cadavers from elderly patients suffering terminal medical illness and free of cervical structural disease were studied. Interventions Destabilizing discoligamentous lesions of the neck were created in the cadavers. Radiographs were taken in maximum displacement in the prone, decubitus and side-bending positions, first unsupported and then with soft, semirigid and hard collars applied. Displacements in angulation and translation were measured from the radiographs. Outcome measures Radiographic displacement under gravity load. Results In all cases there was no effective limitation of pathological displacement, and in many cases displacement was increased after collar application. Conclusions Cervical collars do not effectively support the unstable neck, and may be ineffective in preventing pathological displacements. PMID:15362326

  19. Morphological study of the uncommon rectus sterni muscle in ...

    African Journals Online (AJOL)

    Objective: The present investigation has been designed to study the incidence of the rectus stern muscle in German human cadavers dissected in the Kingdom of Saudi Arabia, trying to find a postulation for the development of such muscle when present. Design: Gross dissection of 130 cadavers, of both sexes, was ...

  20. Fibrocartilage in various regions of the human glenoid labrum. An immunohistochemical study on human cadavers.

    Science.gov (United States)

    Ockert, Ben; Braunstein, Volker; Sprecher, Christoph M; Shinohara, Yasushi; Milz, Stefan

    2012-06-01

    The nature and the distribution of fibrocartilage at the human glenoid labrum are unclear, and a better understanding may help to restore its function in open and arthroscopic Bankart repair. Aim of this study was to describe the fibrocartilage extent within the labrum at clinically relevant sites of the glenoid in order to relate the molecular composition of the labrum to its mechanical environment. Twelve fresh frozen human cadaveric shoulders (mean age 38 years) were obtained, and sections perpendicular to the glenoid rim at the 12, 2, 3, 4, 6 and 9 o' clock position were labelled with antibodies against collagen I and II, aggrecan and link protein. A fibrocartilaginous transition zone with a characteristic collagen fibre orientation was found in 81% of cases, evenly distributed (83-92%) around the glenoid rim. The percentage of labrum cross-sectional area comprised of fibrocartilage averaged 28% and ranged from 26% at 12 o'clock on the glenoid clock face to 30% at 3 o'clock. The highest amount of fibrocartilage (82%) was found in the region neighbouring the hyaline articular cartilage. In the region beyond the bony edge of the glenoid, fibrocartilage cross-sectional area did not exceed 12-17%. Fibrocartilage is present at all examined positions around the glenoid rim and constitutes up to 1/3 of the cross-sectional area of the labrum. In turn, the percentage of fibrocartilage in different regions of its cross-section varies considerably. The findings suggest that the penetration of fibrocartilaginous tissue may be reduced by avoiding the highly fibrocartilage transition zone during restoration of labral detachment.

  1. Optical clearing of vaginal tissues in cadavers

    Science.gov (United States)

    Chang, Chun-Hung; Hardy, Luke A.; Peters, Michael G.; Bastawros, Dina A.; Myers, Erinn M.; Kennelly, Michael J.; Fried, Nathaniel M.

    2018-02-01

    A nonsurgical laser procedure is being developed for treatment of female stress urinary incontinence (SUI). Previous studies in porcine vaginal tissues, ex vivo, as well as computer simulations, showed the feasibility of using near-infrared laser energy delivered through a transvaginal contact cooling probe to thermally remodel endopelvic fascia, while preserving the vaginal wall from thermal damage. This study explores optical properties of vaginal tissue in cadavers as an intermediate step towards future pre-clinical and clinical studies. Optical clearing of tissue using glycerol resulted in a 15-17% increase in optical transmission after 11 min at room temperature (and a calculated 32.5% increase at body temperature). Subsurface thermal lesions were created using power of 4.6 - 6.4 W, 5.2-mm spot, and 30 s irradiation time, resulting in partial preservation of vaginal wall to 0.8 - 1.1 mm depth.

  2. WHAT IS THE BEST RADIOGRAPHIC VIEW FOR “DIE PUNCH” DISTAL RADIUS FRACTURES? A CADAVER MODEL STUDY

    Science.gov (United States)

    Falcochio, Diego Figueira; Crepaldi, Bruno Eiras; Trindade, Christiano Augusto; da Costa, Antonio Carlos; Chakkour, Ivan

    2015-01-01

    Objective: the aim of this study is try to show the best view for distal radius fractures so called die-punch fractures. Methods: There has been used a human cadaver radius bone from the Salvador Arena Tissue Bank. This bone was cleaned up after removing the soft tissues and osteotomies created displaced lunate fossa fractures of 0, 1, 2, 3 and 5 mm. We have fixed this fragment with adhesive tape. Then the joint deviation were significantly increased with step-offs of 1 mm. Radiographs were then taken into 5 different positions: postero-anterior view, lateral view, oblique views and tangencial view for each of the deviations. The resulting lunate fossa depression in each X-ray film was analyzed by the AutoCAD 2010® software. Results: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. The pronated oblique view was the best to see the 2mm degrees and the oblique supinated view wasn't able to see the degrees between 1 and 2mm. Conclusion: The tangencial view was the best one to see the 1mm and 3mm bone degrees and the second one view to see the 2mm and 5 mm degrees. PMID:27027079

  3. Simulation training using cadaver sheep chest in pleuroscopy - A step towards skills enhancement

    International Nuclear Information System (INIS)

    Mahmud, T.; Saqib, M.; Nasir, T.; Siddique, N.

    2017-01-01

    Objectives: For assessing the use of if simulation training on animal cadavers as a useful tool for training in pleuroscopy. Methods: The email-based cross-sectional study was conducted in December 2014 at Shaikh Zayed Hospital, Federal Postgraduate Medical Institute, Lahore, Pakistan, and comprised respiratory physicians and trainees after their participation in a two-day hands-on training course on pleuroscopy and pleural medical procedures. The responses were analysed and the responses of physicians and trainees were compared. Results: Of the 44 individuals who attended the course and were contacted through emails, 38(86.4%) responded, including 20(52.6%) physicians and 18(47.3%) trainees. All the 38(100%) subjects uniformly accepted the utility of simulation training in enhancing education, improving skill, and improving confidence by repeated practice, and felt that the inclusion of animal models for learning fundamental pleuroscopic procedures can help a lot in teaching. Conclusion: Animal cadavers can be used as an effective teaching tool for pleuroscopy training. (author)

  4. A study of the formation and branching pattern of brachial plexus and its variations in adult human cadavers of north Karnataka

    Directory of Open Access Journals (Sweden)

    Sheetal V Pattanshetti

    2012-01-01

    Full Text Available Introduction and Objectives: The brachial plexus is highly variable, in its formation and branching pattern thus, knowledge of its anatomical patterns, may be insufficient for the surgeon operating on or around these nerves or for the regional anesthesiologist working in this area. Therefore, the present study was an attempt to study further about variations of brachial plexus encountered during routine dissection classes. Materials and Methods: The present descriptive study was carried out by dissection of 60 upper limbs of 30 cadavers, in the age group of 18 to 85 years, obtained during a study period of 2 years from the Department of Anatomy. The plexus was studied in its entire course commencing from the formation in cervical region, course through root of the neck and axilla, up to the main terminal branches of the upper extremity. During the dissection, variations of brachial plexus pertaining to its formation from the roots, trunks, divisions and cords and the branching pattern were observed and data was collected. Results: Out of the 60 cadaveric upper limbs studied for the anatomical variations of the brachial plexus, 2 limbs (3.33% were pre-fixed plexuses. Fusion of adjacent trunks was detected in 2 limbs (3.33%. Variations in branches of lateral cord were detected in 8 limbs (13.33%. Among Posterior cord variations 2-thoracodorsal nerves were detected in 2 limbs (3.33%. All the other branches from brachial plexus had been found to have no anatomical variations. Conclusion: In the present study, an attempt has been made to know the possible variations of the brachial plexus. Though the variations mentioned may not alter the normal functioning of the limb of the individual, but knowledge of the variations is of prime importance to be kept in mind, during anaesthetic and surgical procedures.

  5. Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 arthritic cadaver specimens.

    Science.gov (United States)

    Throckmorton, Thomas W; Gulotta, Lawrence V; Bonnarens, Frank O; Wright, Stephen A; Hartzell, Jeffrey L; Rozzi, William B; Hurst, Jason M; Frostick, Simon P; Sperling, John W

    2015-06-01

    The purpose of this study was to compare the accuracy of patient-specific guides for total shoulder arthroplasty (TSA) with traditional instrumentation in arthritic cadaver shoulders. We hypothesized that the patient-specific guides would place components more accurately than standard instrumentation. Seventy cadaver shoulders with radiographically confirmed arthritis were randomized in equal groups to 5 surgeons of varying experience levels who were not involved in development of the patient-specific guidance system. Specimens were then randomized to patient-specific guides based off of computed tomography scanning, standard instrumentation, and anatomic TSA or reverse TSA. Variances in version or inclination of more than 10° and more than 4 mm in starting point were considered indications of significant component malposition. TSA glenoid components placed with patient-specific guides averaged 5° of deviation from the intended position in version and 3° in inclination; those with standard instrumentation averaged 8° of deviation in version and 7° in inclination. These differences were significant for version (P = .04) and inclination (P = .01). Multivariate analysis of variance to compare the overall accuracy for the entire cohort (TSA and reverse TSA) revealed patient-specific guides to be significantly more accurate (P = .01) for the combined vectors of version and inclination. Patient-specific guides also had fewer instances of significant component malposition than standard instrumentation did. Patient-specific targeting guides were more accurate than traditional instrumentation and had fewer instances of component malposition for glenoid component placement in this multi-surgeon cadaver study of arthritic shoulders. Long-term clinical studies are needed to determine if these improvements produce improved functional outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  6. Evaluation of finger A3 pulley rupture in the crimp grip position - a magnetic resonance imaging cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Uder, Michael; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Adler, Werner [University of Erlangen-Nuremberg, Department of Biometry and Epidemiology, Erlangen (Germany); Schweizer, Andreas [Balgrist, University of Zurich, Department of Orthopaedics, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany)

    2015-09-15

    The correct diagnosis of an A3 pulley rupture is challenging for musculoskeletal radiologists. An A3 pulley rupture should in theory influence the shape of the proximal interphalangeal joint volar plate (VP) and the amount of bowstringing at level of the VP during finger flexion. The purpose of this study was to perform MRI with metric analysis of the VP configuration and VP bowstringing in cadaver fingers in the crimp grip position and to determine cut points for A3 pulley rupture. MRI in the crimp grip position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (fingers with A3 pulley rupture n = 16, fingers without A3 pulley rupture n = 5). The distances of the translation of the VP relative to the middle phalanx base, the distances between the flexor tendons and the VP body, and the distances between the flexor tendon and bone (TB) were measured. Statistical analysis showed significantly lower VP translation distances and significantly higher VP tendon distances if the A3 pulley was ruptured. A2 TB and A4 TB distances did not differ significantly in specimens with and without A3 pulley rupture. The optimal cut points for A3 pulley rupture were a VP translation distance <2.8 mm and a VP tendon distance >1.4 mm. Reduction of the VP translation distance and augmentation of the VP tendon distance are suitable indirect signs of A3 pulley rupture. (orig.)

  7. Refinements of the radiographic cadaver injection technique for investigating minute lymphatic vessels.

    Science.gov (United States)

    Suami, Hiroo; Taylor, G Ian; O'Neill, Jennifer; Pan, Wei-Ren

    2007-07-01

    The authors previously reported a new technique with which to delineate the lymphatic vessels, using hydrogen peroxide to identify them and a lead oxide suspension to demonstrate them on radiographs. This technique provided excellent studies of the lymph vessels in human cadavers, but there was still room for improvement. Lymph collecting vessels run superficially in some regions, where they may be damaged while the surgeon is attempting to find them. Vessels smaller than 0.3 mm in diameter could not be cannulated with a 30-gauge needle, which was the smallest the authors had available, and the lead oxide suspension often blocked this cannula. The authors also encountered problems holding the cannula steady. The authors solved these problems by using a mixture of hydrogen peroxide and ink to better identify the lymphatics, an extruded glass tube instead of a metal needle to cannulate them, an agate pestle and mortar to grind the lead oxide into finer particles, powdered milk to suspend the lead oxide, and a micromanipulator to facilitate accurate and steady cannulation of the vessels. This study developed these modifications to focus on tributaries of the collecting lymphatic channels that are smaller than 0.3 mm in diameter.

  8. Break with tradition: donating cadavers for scientific purposes and reducing the use of sentient beings.

    Science.gov (United States)

    Ciliberti, Rosagemma; Martini, Mariano; Bonsignore, Alessandro; Penco, Susanna

    2016-01-01

    In recent years, the development of research and the increased awareness of our moral duties beyond the human species have pushed the scientific community to revise widely-accepted ontological reductionist views that regard non-human animals as mere things. The new horizons offered by the development of advanced research methods therefore require an on-going commitment to new perspectives able to find the right balance between the need for scientific knowledge on one hand and the respect for animal life on the other. This is in line with increasing attention to animal welfare and expansion of the "3Rs model": replacement, reduction, refinement.With the view of promoting the adoption of alternative methods, human body donation for research can contribute not only to the acquisition of important information for human health and for doctors' training, but also can reduce significantly the number of animals sacrificed.By investigating the scientific and ethical reasons that may encourage cadaver donation, the authors aim to promote the adoption of the practice in Italy following other European experiences.

  9. Acute Q fever infection in Thuringia, Germany, after burial of roe deer fawn cadavers (Capreolus capreolus: a case report

    Directory of Open Access Journals (Sweden)

    B.T. Schleenvoigt

    2015-11-01

    Full Text Available We report on a case of a 48-year-old man who presented with acute Q fever infection after burying two fawn cadavers (Capreolus capreolus. Recent outbreaks of Q fever in Europe have been traced back to intensive goat breeding units, sheep flocks in the proximity of highly populated urban areas or to farmed deer. To our knowledge, this is the first case report describing Q fever infection in a human linked to roe deer as a source of infection.

  10. Scoring of Decomposition: A Proposed Amendment to the Method When Using a Pig Model for Human Studies.

    Science.gov (United States)

    Keough, Natalie; Myburgh, Jolandie; Steyn, Maryna

    2017-07-01

    Decomposition studies often use pigs as proxies for human cadavers. However, differences in decomposition sequences/rates relative to humans have not been scientifically examined. Descriptions of five main decomposition stages (humans) were developed and refined by Galloway and later by Megyesi. However, whether these changes/processes are alike in pigs is unclear. Any differences can have significant effects when pig models are used for human PMI estimation. This study compared human decomposition models to the changes observed in pigs. Twenty pigs (50-90 kg) were decomposed over five months and decompositional features recorded. Total body scores (TBS) were calculated. Significant differences were observed during early decomposition between pigs and humans. An amended scoring system to be used in future studies was developed. Standards for PMI estimation derived from porcine models may not directly apply to humans and may need adjustment. Porcine models, however, remain valuable to study variables influencing decomposition. © 2016 American Academy of Forensic Sciences.

  11. Evaluation of serosal patch supplementation of surgical anastomoses in intestinal segments from canine cadavers.

    Science.gov (United States)

    Hansen, Lane A; Monnet, Eric L

    2013-08-01

    To compare leakage and maximum intraluminal pressures of intestinal anastomoses with and without serosal patch supplementation in dogs. Healthy small intestine segments from cadavers of 2 dogs euthanized for reasons unrelated to the study. 12 enterectomy constructs were created by anastomosis of intestinal segments with a standard simple continuous suture pattern. Half of the constructs were randomly selected for additional serosal patch support. Leakage and maximum intraluminal pressures were measured in and compared between patch-supplemented and nonsupplemented constructs. Mean ± SD leakage pressure was significantly greater for the patch-supplemented anastomoses (81.8 ± 6.7 mm Hg) than for the nonsupplemented anastomoses (28.0 ± 6.7 mm Hg). Maximum intraluminal pressures were not significantly different between the groups. Serosal patch-supplemented anastomoses were able to sustain a significantly higher pressure before leakage than were nonsupplemented anastomoses in intestinal specimens from canine cadavers. The serosal patch supplementation may protect against leakage immediately after enterectomy in dogs.

  12. Shoulder Arthroscopy Simulator Training Improves Shoulder Arthroscopy Performance in a Cadaver Model

    Science.gov (United States)

    Henn, R. Frank; Shah, Neel; Warner, Jon J.P.; Gomoll, Andreas H.

    2013-01-01

    Purpose The purpose of this study was to quantify the benefits of shoulder arthroscopy simulator training with a cadaver model of shoulder arthroscopy. Methods Seventeen first year medical students with no prior experience in shoulder arthroscopy were enrolled and completed this study. Each subject completed a baseline proctored arthroscopy on a cadaveric shoulder, which included controlling the camera and completing a standard series of tasks using the probe. The subjects were randomized, and nine of the subjects received training on a virtual reality simulator for shoulder arthroscopy. All subjects then repeated the same cadaveric arthroscopy. The arthroscopic videos were analyzed in a blinded fashion for time to task completion and subjective assessment of technical performance. The two groups were compared with students t-tests, and change over time within groups was analyzed with paired t-tests. Results There were no observed differences between the two groups on the baseline evaluation. The simulator group improved significantly from baseline with respect to time to completion and subjective performance (parthroscopy simulator training resulted in significant benefits in clinical shoulder arthroscopy time to task completion in this cadaver model. This study provides important additional evidence of the benefit of simulators in orthopaedic surgical training. Clinical Relevance There may be a role for simulator training in shoulder arthroscopy education. PMID:23591380

  13. SimLife a new model of simulation using a pulsated revascularized and reventilated cadaver for surgical education.

    Science.gov (United States)

    Delpech, P O; Danion, J; Oriot, D; Richer, J P; Breque, C; Faure, J P

    2017-02-01

    Alike becoming a pilot requires competences, acquisition of technical skills is essential to become a surgeon. Halsted's theory on surgical education "See one, do one, and teach one" is not currently compatible with the reality of socio-economic constraints of the operating room, the patient's safety demand and the reduction of residents' work hours. In all countries, this brings mandatory to simulation education for surgery resident's training. Many models are available: video trainers or pelvi-trainers, computed simulator, animal models or human cadaver… Human cadaveric dissection has long been used to teach surgical anatomy. Surgery on human cadaveric model brings greatest accuracy to the haptic characteristics of surgical procedures. Learning in an appropriate and realistic simulation context increases the level of acquisition of the residents' skills and reduces stress and anxiety when performing real procedures. We present a technique of perfusion and ventilation of a fresh human cadaver that restores pulsatile circulation and respiratory movements of the model. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. A new noninvasive controlled intra-articular ankle distraction technique on a cadaver model.

    Science.gov (United States)

    Aydin, Ahmet T; Ozcanli, Haluk; Soyuncu, Yetkin; Dabak, Tayyar K

    2006-08-01

    Effective joint distraction is crucial in arthroscopic ankle surgery. We describe an effective and controlled intra-articular ankle distraction technique that we have studied by means of a fresh-frozen cadaver model. Using a kyphoplasty balloon, which is currently used in spine surgery, we tried to achieve a controlled distraction. After the fixation of the cadaver model, standard anteromedial and anterolateral portals were used for ankle arthroscopy. From the same portals, the kyphoplasty balloon was inserted and placed in an appropriate position intra-articularly. The necessary amount of distraction was achieved by inflating the kyphoplasty balloon with a pressure regulation pump. All anatomic sites of the ankle joint were easily visualized with the arthroscope during surgery by changing the pressure and the intra-articular position of the kyphoplasty balloon. Ankle distraction was clearly seen on the arthroscopic and image intensifier view. The kyphoplasty balloon is simple to place through the standard portals and the advantage is that it allows easy manipulation of the arthroscopic instruments from the same portal.

  15. The assessment of virtual reality for human anatomy instruction

    Science.gov (United States)

    Benn, Karen P.

    1994-01-01

    This research project seeks to meet the objective of science training by developing, assessing, and validating virtual reality as a human anatomy training medium. In ideal situations, anatomic models, computer-based instruction, and cadaver dissection are utilized to augment the traditional methods of instruction. At many institutions, lack of financial resources limits anatomy instruction to textbooks and lectures. However, human anatomy is three dimensional, unlike the one dimensional depiction found in textbooks and the two dimensional depiction found on the computer. Virtual reality is a breakthrough technology that allows one to step through the computer screen into a three dimensional world. This technology offers many opportunities to enhance science education. Therefore, a virtual testing environment of the abdominopelvic region of a human cadaver was created to study the placement of body parts within the nine anatomical divisions of the abdominopelvic region and the four abdominal quadrants.

  16. The Use of a Fresh-Tissue Cadaver Model for the Instruction of Dermatological Procedures: A Laboratory Study for Training Medical Students.

    Science.gov (United States)

    Cervantes, Jose A; Costello, Collin M; Maarouf, Melody; McCrary, Hilary C; Zeitouni, Nathalie C

    2017-09-01

    A realistic model for the instruction of basic dermatologic procedural skills was developed, while simultaneously increasing medical student exposure to the field of dermatology. The primary purpose of the authors' study was to evaluate the utilization of a fresh-tissue cadaver model (FTCM) as a method for the instruction of common dermatologic procedures. The authors' secondary aim was to assess students' perceived clinical skills and overall perception of the field of dermatology after the lab. Nineteen first- and second-year medical students were pre- and post-tested on their ability to perform punch and excisional biopsies on a fresh-tissue cadaver. Students were then surveyed on their experience. Assessment of the cognitive knowledge gain and technical skills revealed a statistically significant improvement in all categories (p < .001). An analysis of the survey demonstrated that 78.9% were more interested in selecting dermatology as a career and 63.2% of participants were more likely to refer their future patients to a Mohs surgeon. An FTCM is a viable method for the instruction and training of dermatologic procedures. In addition, the authors conclude that an FTCM provides realistic instruction for common dermatologic procedures and enhances medical students' early exposure and interest in the field of dermatology.

  17. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  18. Sex Hormone Receptor Expression in the Human Vocal Fold Subunits.

    Science.gov (United States)

    Kirgezen, Tolga; Sunter, Ahmet Volkan; Yigit, Ozgur; Huq, Gulben Erdem

    2017-07-01

    The study aimed to evaluate the existence of sex hormone receptors in the subunits of vocal fold. This is a cadaver study. The androgen, estrogen, and progesterone receptors were examined in the epithelium (EP), superficial layer of the lamina propria (SLP), vocal ligament (VL), and macula flava (MF) of the vocal folds from 42 human cadavers (21 male, 21 female) by immunohistochemical methods. Their staining ratios were scored and statistically compared. The androgen receptor score was significantly higher for the MF than for the EP and SLP (P vocal fold, mostly in the MF and VLs. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  19. Evaluation of brachial plexus fascicles involvement on infraclavicular block: unfixed cadaver study

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Buarque de Gusmão

    2015-06-01

    Full Text Available BACKGROUND AND OBJECTIVES: This study shows how the diffusion of the anesthetic into the sheath occurs through the axillary infraclavicular space and hence proves the efficacy of the anesthetic block of the brachial plexus, and may thereby allow a consolidation of this pathway, with fewer complications, previously attached to the anesthesia. MATERIALS AND METHODS: 33 armpits of adult cadavers were analyzed and unfixed. We injected a solution of neoprene with latex dye in the infraclavicular space, based on the technique advocated by Gusmão et al., and put the corpses in refrigerators for three weeks. Subsequently, the specimens were thawed and dissected, exposing the axillary sheath along its entire length. RESULTS AND DISCUSSION: Was demonstrated involvement of all fasciculus of the plexus in 51.46%. In partial involvement was 30.30%, 18.24% of cases the acrylic was located outside the auxiliary sheath involving no issue. CONCLUSIONS: The results allow us to establish the infraclavicular as an effective and easy way to access plexus brachial, because the solution involved the fascicles in 81.76% partially or totally, when it was injected inside the axillary sheath. We believe that only the use of this pathway access in practice it may demonstrate the efficiency.

  20. Volume and planar gated cardiac magnetic resonance imaging: a correlative study of normal anatomy with Thallium-201 SPECT and cadaver sections

    International Nuclear Information System (INIS)

    Go, R.T.; MacIntyre, W.J.; Yeung, H.N.

    1984-01-01

    Magnetic resonance (MR) gated cardiac imaging was performed in ten subjects using a prototype 0.15-T resistive magnet imaging system. Volume and planar imaging techniques utilizing saturation recovery, proton TI-weighted relaxation time pulse sequences produced images of the heart and great vessels with exquisite anatomic detail that showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with the thallium-201 cardiac single photon emission computed tomography images. Volume acquisition allowed postprocessing selection of tomographic sections in various orientations to optimize visualization of a particular structure of interest. The excellent spatial and contrast resolution afforded by MR volume imaging, which does not involve the use of ionizing radiation and iodinated contrast material, should assure it a significant role in the diagnostic assessment of the cardiovascular system

  1. da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.

    Science.gov (United States)

    Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar

    2015-04-01

    The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.

  2. Correlations Between the Autolytic Changes and Postmortem Interval in Refrigerated Cadavers

    Directory of Open Access Journals (Sweden)

    Cocariu Ela Andra

    2016-06-01

    Full Text Available Introduction. In forensic pathology the autolytic process has been observed and documented in order to determine the postmortem interval as accurately as possible. The observation and experiments have been carried out on cadavers exposed to environmental conditions – heat, humidity, air currents, soil, water.

  3. Biomechanical evaluation of native acromioclavicular joint ligaments and two reconstruction techniques in the presence of the sternoclavicular joint: A cadaver study.

    Science.gov (United States)

    Masionis, Povilas; Šatkauskas, Igoris; Mikelevičius, Vytautas; Ryliškis, Sigitas; Bučinskas, Vytautas; Griškevičius, Julius; Martin Oliva, Xavier; Monzó Planella, Mariano; Porvaneckas, Narūnas; Uvarovas, Valentinas

    2017-01-01

    Where is over 100 reconstruction techniques described for acromioclavicular (AC) joint reconstruction. Although, it is not clear whether the presence of the sternoclavicular (SC) joint influences the biomechanical properties of native AC ligaments and reconstruction techniques. The purpose of the present study was to investigate the biomechanical properties of native AC joint ligaments and two reconstruction techniques in cadavers with the SC joint still present. We tested eight fresh-frozen cadaver hemithoraces for superior translation (70 N load) and translation increment after 1000 cycles (loading from 20 to 70 N) in a controlled laboratory study. There were three testing groups created: native ligaments, the single coracoclavicular loop (SCL) technique, and the two coracoclavicular loops (TCL) technique. Superior translation was measured after static loading. Translation increment was calculated as the difference between superior translation after cyclic and static loading. Native AC ligaments showed significantly lower translation than the SCL ( p = 0.023) and TCL ( p = 0.046) groups. The SCL had a significantly lower translation increment than native AC ligaments ( p = 0.028). There was no significant difference between reconstruction techniques in terms of translation ( p = 0.865) and translation increment ( p = 0.113). Native AC joint ligaments had better static properties than both reconstruction techniques and worse dynamic biomechanical properties than the SCL technique. The SCL technique appeared to be more secure than the TCL technique. The presence of the SC joint did not have an observable influence on test results.

  4. Safety zone for posterosuperior shoulder access: study on cadavers

    Directory of Open Access Journals (Sweden)

    Miguel Pereira Costa

    2016-08-01

    Full Text Available ABSTRACT OBJECTIVE: The posterosuperior shoulder access used in surgical treatment for acromioclavicular dislocation was constructed through dissection of 20 shoulders from 10 recently chilled adult cadavers, and the distances from this route to the nearby neurovascular structures were analyzed. METHODS: A Kirschner wire was introduced into the top of the base of the coracoid process through the posterosuperior shoulder access, in the area of the origin of the conoid and trapezoid ligaments, thus reproducing the path for inserting two anchors for anatomical reconstruction of the coracoclavicular ligaments. The smallest distance from the insertion point of the Kirschner wire to the suprascapular nerve and artery/vein was measured. RESULTS: The mean distance from the suprascapular nerve to the origin of the coracoclavicular ligaments at the top of the base of the coracoid process was 18.10 mm (range: 13.77-22.80 in the right shoulder and 18.19 mm (range: 12.59-23.75 in the left shoulder. The mean distance from the suprascapular artery/vein to the origin of the coracoclavicular ligaments was 13.10 mm (range: 9.28-15.44 in the right shoulder and 14.11 mm (range: 8.83-18.89 in the left shoulder. Comparison between the contralateral sides did not show any statistical difference. CONCLUSION: The posterosuperior shoulder access route for anatomical reconstruction of the coracoclavicular ligaments in treating acromioclavicular dislocation should be performed respecting the minimum limit of 8.83 mm medially.

  5. Necropsy of a cadaver containing 50 mmCi of Na-131I

    International Nuclear Information System (INIS)

    Parthasarathy, K.L.; Komerek, M.; Quain, B.; Bakshi, S.P.; Qureshi, F.; Shimaoka, K.; Rao, U.; Adamski, J.S.; Bender, M.A.

    1982-01-01

    A patient who received an oral dose of 131 I for the treatment of metastatic thyroid carcinoma unexpectedly died with a large total-body retention of the radioiodine. An autopsy was required and the family requested the body to be transported out of state to their home town. Since the radiation intensity near the surface of the cadaver was above 200 mR/hr, advanced planning and special precautions were necessary in order for the autopsy to proceed safely. This required the immediate cooperation of the pathologists, nuclear medicine physicians, health physicists, an endocrine oncologist, and other hospital staff. As a result of team efforts, personnel radiation exposures were kept as low as reasonably achievable, contamination of the autopsy room was minimal, and the radiation level of the cadaver was adequately reduced for safe transport and burial

  6. Feasibility and Benefit of Incorporating a Multimedia Cadaver Laboratory Training Program into a Didactics Curriculum for Junior and Senior Surgical Residents.

    Science.gov (United States)

    Simmerman, Erika; Simmerman, Andrew; Lassiter, Randi; King, Ray; Ham, Ben; Adam, Bao-Ling; Ferdinand, Colville; Holsten, Steven

    2018-04-17

    As operative experience in general surgery decreases and work hour limitations increase there is less exposure of surgical residents to advanced vascular and trauma exposures. Many institutions have demonstrated benefits of cadaver laboratory courses. We have incorporated a multimedia cadaver laboratory course into our general surgery residency didactics curriculum with the objective to demonstrate a benefit of the program as well as the feasibility of incorporation. This is a prospective study at a tertiary care institution including general surgery residents within our residency program. A curriculum was designed, requiring residents to complete multimedia learning modules before both a trauma cadaver laboratory and vascular exposure cadaver laboratory. Outcome measures included self-efficacy/confidence (precourse and postcourse 5-point Likert surveys), knowledge (net performance on precourse and postcourse multiple choice examinations), and resident perception of the curriculum (postcourse 5-point Likert survey). Data were analyzed using ANOVA paired t-tests. For the vascular cadaver laboratory, resident knowledge improved overall from an average of 41.2% to 50.0% of questions correct (p = 0.032) and self-efficacy/confidence improved by 0.59 from 1.52 to 2.11 out of 5 (p = 0.009). Median confidence is 1.37 out of 5 and 2.32 out of 5, before and after course, respectively. Wilcoxon nonparametric test reveals a p = 0.011. Resident's perception of the usefulness of the laboratory evaluation was 3.85 out 5. There were 85.71% agreed that the laboratory is useful and 14.29% were disagree. The Z-score is -0.1579 (means 0.1579 standard deviations a score of 3.85 below the benchmark). The percentile rank is 56.27%. The coefficient of variation is 24.68%. For the trauma cadaver laboratory, resident knowledge improved overall from an average of 55.89% to 66.17% of questions correct (p = 0.001) and self-efficacy/confidence improved by 0.75 from 1.68 out of 5 to 2.43 out of

  7. A novel supra-temporal approach to retrobulbar anaesthesia in dogs: Preliminary study in cadavers.

    Science.gov (United States)

    Chiavaccini, Ludovica; Micieli, Fabiana; Meomartino, Leonardo; Duffee, Lauren R; Vesce, Giancarlo

    2017-05-01

    A novel supra-temporal technique for retrobulbar anaesthesia in dogs is described and compared to the inferior temporal palpebral approach. Supra-temporal and inferior temporal palpebral retrobulbar injections were performed in 20 orbits of canine cadavers. Distribution of injected contrast medium within the intraconal space and around the optic nerve was analysed using computed tomography. There was adequate distribution of contrast medium within the intraconal space with both techniques. Concurrent intraconal and extraconal distribution was observed using the inferior temporal palpebral approach in 3/10 orbits and using the supra-temporal approach in 5/10 orbits. In 3/10 supra-temporal injections, the injected vehicle was distributed preferentially in the caudal aspect of the retrobulbar cone, closer to the orbital fissure. Accidental intraocular injection was never observed. The supra-temporal approach appears to be a valid alternative to the inferior temporal palpebral approach for retrobulbar anaesthesia in dogs, being less technically challenging. Further studies are required to confirm the clinical efficacy of this approach in dogs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures.

    Science.gov (United States)

    Basso, Trude; Klaksvik, Jomar; Syversen, Unni; Foss, Olav A

    2014-12-18

    Fourth generation composite femurs (4GCFs, models #3406 and #3403) simulate femurs of males cadaver femurs (HCFs) selected to represent patients with hip fractures. Ten 4GCFs (Sawbones, Pacific Research Laboratories, Inc., Vashon, WA, USA) were compared to 24 HCFs from seven females and five males >60 years. Proximal femur anthropometric measurements were noted. Strain gauge rosettes were attached and femurs were mounted in a hip simulator applying a combined subject-specific axial load and torque. Baseline measurements of resistance to deformation were recorded. Standardized femoral neck fractures were surgically stabilized before the constructs were subjected to 20,000 load-cycles. An optical motion tracking system measured relative movements. Median (95% CI) head fragment migration was 0.8mm (0.4 to 1.1) in the 4GCF group versus 2.2mm (1.5 to 4.6) in the cadaver group (p=0.001). This difference in fracture stability could not be explained by observed differences in femoral anthropometry or potential overloading of 4GCFs. 4GCFs failed with fracture-patterns different from those observed in cadavers. To conclude, standard 4GCFs provide unrealistically stable bone-implant constructs and fail with fractures not observed in cadavers. Until a validated osteopenic or osteoporotic composite femur model is provided, standard 4GCFs should only be used when representing the biomechanical properties of young healthy femurs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Evaluation of a novel suture material for closure of intestinal anastomoses in canine cadavers.

    Science.gov (United States)

    Hansen, Lane A; Monnet, Eric L

    2012-11-01

    To compare leakage and maximum intraluminal pressures for a novel suture material with pressures for comparable suture material when used in closure of intestinal anastomoses in canine cadavers. Healthy intestines from cadavers of dogs euthanized for reasons unrelated to the study. 18 anastomoses were performed on intestinal sections within 72 hours after dogs were euthanized and intestinal samples collected. Anastomoses were performed with a simple continuous suture pattern. Leakage and maximum intraluminal pressures were measured and recorded for 6 control segments and 18 anastomosed sections. A barbed glycomer 631 suture (size 4-0 United States Pharmacopeia [USP]) was compared with glycomer 631 sutures (sizes 3-0 and 4-0 USP). Results for leakage and maximum intraluminal pressures were compared via an ANOVA. The barbed glycomer 631 suture material leaked at a significantly higher pressure than did the comparable glycomer 631 suture materials. Maximum intraluminal pressures were not significantly different among the suture materials. Barbed glycomer 631 4-0 USP suture material was as effective as glycomer 631 suture materials and may be a safe alternative for use in closure of enterectomies in dogs.

  10. Computer Modeling and Simulation of Bullet Impact to the Human Thorax

    National Research Council Canada - National Science Library

    Jolly, Johannes

    2000-01-01

    .... The objective of the study was to create a viable finite element model of the human thorax. The model was validated by comparing the results of tests of body armor systems conducted on cadavers to results obtained from finite element analysis...

  11. Mechanized Packing and Delivery System for Entomopathogenic Nematodes in Infected Mealworm Cadavers

    Science.gov (United States)

    This document describes a mechanized system to pack mealworm (Tenebrio molitor) cadavers infected with entomopathogenic nematodes between two sheets of masking tape. The document is also an operation manual for the machine and provides all the machine specifications, and wiring and pneumatic diagram...

  12. Medial extent of the anterior Gerota's fascia: An anatomic study using cadaver and CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jae Hoon; Ryu, Kyung Nam; Kim, Ho Kyun; Yoon, Yup; Lee, Sun Wha; Ko, Young Tae; Choi, Woo Suk; Lee, Dong Ho [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1989-04-15

    To study the anatomy of the perirenal space, authors dissected two cadavers and reviewed 50 computed tomographic (CT) scans, laying special emphasis on the medial extent of the anterior layer of Gerota's fascia. It is concluded that, below the renal hilus level, anterior layers of the right and left Gerota's fascia fuse each other across the midline anterior to the aorta and inferior vena cava. Above the hilus level, anterior layers are very weak and seem to fuse with the parietal peritoneum or adjacent organs. Therefore, the right and left perirenal space may communicate across the midline, anterior to the lower aorta and vena cava. Thus, at least in some subjects, the perirenal fluid or blood of the right or left perirenal space may extend to the opposite perirenal space through the narrow midline extension of each perirenal spaces anterior to the vertebral body.

  13. A study on the resistance at bone-implant interface during implant insertion in a cadaver goat jaw model

    Directory of Open Access Journals (Sweden)

    Goutam Das

    2016-01-01

    Full Text Available Background: The aim of the study is to determine the resistance at bone-implant interface during insertion of dental implant. Materials and Methods: Freshly procured cadaver goat mandibles were collected from slaughterhouses. Four dental implants of two different diameters were inserted into osteotomized sites of the goat mandibles. The gradual changes in resonance frequency (RF were recorded in RF analyzer for the five consecutive turns of implant insertion. Results and Observations: RF was found to be positively correlated with diameter of dental implants. Conclusion: RF analysis can be used to determine the type of resistance the implant faces during insertion and the kind of bone density through which it passes. It gives a forecast of expected initial stability.

  14. Development of a fresh cadaver model for instruction of ultrasound-guided breast biopsy during the surgery clerkship: pre-test and post-test results among third-year medical students.

    Science.gov (United States)

    McCrary, Hilary C; Krate, Jonida; Savilo, Christine E; Tran, Melissa H; Ho, Hang T; Adamas-Rappaport, William J; Viscusi, Rebecca K

    2016-11-01

    The aim of our study was to determine if a fresh cadaver model is a viable method for teaching ultrasound (US)-guided breast biopsy of palpable breast lesions. Third-year medical students were assessed both preinstruction and postinstruction on their ability to perform US-guided needle aspiration or biopsy of artificially created masses using a 10-item checklist. Forty-one third-year medical students completed the cadaver laboratory as part of the surgery clerkship. Eight items on the checklist were found to be significantly different between pre-testing and post-testing. The mean preinstruction score was 2.4, whereas the mean postinstruction score was 7.10 (P cadaver models have been widely used in medical education. However, there are few fresh cadaver models that provide instruction on procedures done in the outpatient setting. Our model was found to be an effective method for the instruction of US-guided breast biopsy among medical students. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Paech, Daniel [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany); Giesel, Frederik L. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Unterhinninghofen, Roland [Institute of Anthropomatics, Karlsruhe Institute of Technology, Karlsruhe (Germany); Schlemmer, Heinz-Peter [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kuner, Thomas; Doll, Sara [Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany)

    2017-05-15

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n{sub 1} = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n{sub 2} = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n{sub 3} = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. circle Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. (orig.)

  16. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy

    International Nuclear Information System (INIS)

    Paech, Daniel; Giesel, Frederik L.; Unterhinninghofen, Roland; Schlemmer, Heinz-Peter; Kuner, Thomas; Doll, Sara

    2017-01-01

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n_1 = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n_2 = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n_3 = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. circle Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. (orig.)

  17. Investigation of radialization and rerouting of the extensor digiti minimi (EDM) in the abduction deformity of the little finger: a cadaver study.

    Science.gov (United States)

    van Aaken, Jan; Zhu, Jin; Fasel, Jean H D; Beaulieu, Jean-Yves

    2011-06-01

    One of several operations to correct abduction deformity of the little finger, (Wartenberg's sign) in ulnar nerve palsy, is a combined procedure that radializes the extensor digiti minimi (EDM) at the level of the fifth metacarpophalangeal (MCP) joint and reroutes it from the fifth to fourth extensor compartment. This cadaveric study was designed to investigate the impact of both elements on adduction. Anatomy of the little finger extensor apparatus was studied in 16 freshly frozen cadaver hands sectioned at mid forearm. We observed little finger motion after different modifications of the EDM. We tested the effect of a rerouting maneuver by pulling on the EDM, as well as radialization of the EDM alone and in combination with rerouting. The EDM was present in all cases. Little finger extensor digitorum communis (EDC(V)) was missing in two cadavers. In no case was adduction created by rerouting the EDM to the fourth compartment. Radialization of the EDM corrected the abduction deformity beyond the axis of abduction/adduction of the fifth MCP joint in 13 cases and only up to it in three cases. In one of the three with limited correction, a rerouting maneuver allowed for further adduction. The key to correct abduction deformity of the little finger is radialization of the EDM, which can be done through a solitary incision at the level of the MCP joint. Rerouting alone does not correct the abduction deformity, and in combination with radialization it does not predictably enhance the correction.

  18. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy.

    Science.gov (United States)

    Paech, Daniel; Giesel, Frederik L; Unterhinninghofen, Roland; Schlemmer, Heinz-Peter; Kuner, Thomas; Doll, Sara

    2017-05-01

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n 1  = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n 2  = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n 3  = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. • Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. • Radiological education integrated into gross anatomy is highly appreciated by medical students. • Simultaneous physical and virtual dissection provide unique conditions to study anatomy.

  19. Examining High School Anatomy and Physiology Teacher Experience in a Cadaver Dissection Laboratory and Impacts on Practice

    Science.gov (United States)

    Mattheis, Allison; Ingram, Debra; Jensen, Murray S.; Jackson, Jon

    2015-01-01

    This article describes the results of a study that investigated the experiences of a group of high school anatomy and physiology teachers who participated in a cadaver dissection laboratory workshop organized through a university-school partnership. Teacher feedback was collected before, during, and after the workshop through pre-arrival surveys,…

  20. Biomechanical analysis of range of motion and failure characteristics of osteoporotic spinal compression fractures in human cadaver

    Directory of Open Access Journals (Sweden)

    Robert F Heary

    2017-01-01

    Full Text Available Background: Vertebroplasty is a treatment for osteoporotic vertebral compression fractures. The optimal location of needle placement for cement injection remains a topic of debate. As such, the authors assessed the effects of location of two types of cement instillations. In addition, the motion and failure modes at the index and adjacent segments were measured. Materials and Methods: Seven human osteoporotic cadaver spines (T1-L4, cut into four consecutive vertebral segments, were utilized. Of these, following the exclusion of four specimens not suitable to utilize for analysis, a total of 24 specimens were evaluable. Segments were randomly assigned into four treatment groups: unipedicular and bipedicular injections into the superior quartile or the anatomic center of the vertebra using confidence (Confidence Spinal Cement System®, DePuy Spine, Raynham, MA, USA or polymethyl methacrylate. The specimens were subjected to nondestructive pure moments of 5 Nm, in 2.5 Nm increments, using pulleys and weights to simulate six degrees of physiological motion. A follower preload of 200 N was applied in flexion extension. Testing sequence: range of motion (ROM of intact specimen, fracture creation, cement injection, ROM after cement, and compression testing until failure. Nonconstrained motion was measured at the index and adjacent levels. Results: At the index level, no significant differences were observed in ROM in all treatment groups (P > 0.05. There was a significant increase in adjacent level motion only for the treatment group that received a unipedicular cement injection at the anatomic center. Conclusion: The location of the needle (superior or central and treatment type (unipedicular or bipedicular had no significant effect on the ROM at the index site. At the adjacent levels, a significant increase occurred with therapy through a unipedicular approach into the centrum of the vertebra at the treated segment.

  1. Electroosmotic pore transport in human skin.

    Science.gov (United States)

    Uitto, Olivia D; White, Henry S

    2003-04-01

    To determine the pathways and origin of electroosmotic flow in human skin. Iontophoretic transport of acetaminophen in full thickness human cadaver skin was visualized and quantified by scanning electrochemical microscopy. Electroosmotic flow in the shunt pathways of full thickness skin was compared to flow in the pores of excised stratum corneum and a synthetic membrane pore. The penetration of rhodamine 6G into pore structures was investigated by laser scanning confocal microscopy. Electroosmotic transport is observed in shunt pathways in full thickness human skin (e.g., hair follicles and sweat glands), but not in pore openings of freestanding stratum corneum. Absolute values of the diffusive and iontophoretic pore fluxes of acetaminophen in full thickness human skin are also reported. Rhodamine 6G is observed to penetrate to significant depths (approximately 200 microm) along pore pathways. Iontophoresis in human cadaver skin induces localized electroosmotic flow along pore shunt paths. Electroosmotic forces arise from the passage of current through negatively charged mesoor nanoscale pores (e.g., gap functions) within cellular regions that define the pore structure beneath the stratum corneum.

  2. Vertebral osteoporosis: perfused animal cadaver model for testing new vertebroplastic agents.

    Science.gov (United States)

    Hoell, Thomas; Huschak, Gerald; Beier, Andre; Holzhausen, Hans-Juergen; Meisel, Hans-Joerg; Emmrich, Frank

    2010-12-01

    Experimental study. It was aimed to establish a cadaver model to imitate osteoporotic perfused vertebral bone and to allow for transpedicular transfer of bone cement and various new materials into vertebrae. The model was perfused to simulate vertebroplasty in the presence of transvertebral blood flow. The injection of bone cement into vertebrae bears the risk of irreversible discharge of material into the venous system of the spinal canal. The bovine cadaver model studied allows visual studies of material distribution in a vertebral bone, the potential spill-out of material, and quantification of washout and disintegration phenomena. Thoracic and lumbar vertebrae from 1-year-old calves were cut transversally into 5 mm slices, macerated, and decalcified. The softened bone slices were compressed between 2 transparent plastic discs. A standard vertebroplasty cannula (outer diameter 3.5 mm, inner diameter 2.5 mm) was inserted into the vertebral body via the pedicle to transfer the different vertebroplasty materials. Arterial blood flow was simulated by means of liquid irrigation via 2 needles in the ventral part of the vertebral body slice. Metal powder was mixed with the solution to indicate the blood flow in the bone. The model was evaluated with the vertebroplasty cement polymethylmethacrylate. The model permitted visualization of the insertion and distribution of vertebroplasty materials. Liquid bone cement was effused into the spinal canal as in the clinical situation. Higher modulus cement acted in the same way as in clinical vertebroplasty. Rigid vertebroplasty agents led to trabecular fractures and stable mechanical interactions with the bone and eventually moved dorsal bone fragments into the spinal canal. Sedimentation of the metal powder indicated regions of perfusion. The model simulated the clinical behavior of liquid and higher modulus vertebroplasty agents in the presence of blood flow. It enabled safe ex vivo testing of the mechanical and physical

  3. Audiovisual Material as Educational Innovation Strategy to Reduce Anxiety Response in Students of Human Anatomy

    Science.gov (United States)

    Casado, Maria Isabel; Castano, Gloria; Arraez-Aybar, Luis Alfonso

    2012-01-01

    This study presents the design, effect and utility of using audiovisual material containing real images of dissected human cadavers as an innovative educational strategy (IES) in the teaching of Human Anatomy. The goal is to familiarize students with the practice of dissection and to transmit the importance and necessity of this discipline, while…

  4. Further evidence on the anatomical placement of the human eyeball for facial approximation and craniofacial superimposition.

    Science.gov (United States)

    Stephan, Carl N; Huang, Anne J R; Davidson, Paavi L

    2009-03-01

    Recently a small sampled cadaver study (n = 4) suggested that the human eyeballs are placed closer to the orbital roof and lateral orbital wall as first reported in the anatomical literature many years previously. This contrasts with central positioning of the eyeball within the orbit as advocated by the facial approximation literature. Given the limits of such small samples, this study re-examined globe position in nine new cadavers to help clarify which relationship is accurate. The results essentially confirm prior empirical findings except that the mean lateral divergences from the orbit center were found to be larger--the eyeball was found to be "displaced" 1.4 mm superiorly and 2.4 mm laterally. Medians calculated across all 13 cadavers from this study and the above-mentioned recent report refine these measurements to 1.4 and 2.3 mm respectively. Globe projection values were identical to those observed for living individuals (c. 16 mm).

  5. Indoors forensic entomology: colonization of human remains in closed environments by specific species of sarcosaprophagous flies.

    Science.gov (United States)

    Pohjoismäki, Jaakko L O; Karhunen, Pekka J; Goebeler, Sirkka; Saukko, Pekka; Sääksjärvi, Ilari E

    2010-06-15

    Fly species that are commonly recovered on human corpses concealed in houses or other dwellings are often dependent on human created environments and might have special features in their biology that allow them to colonize indoor cadavers. In this study we describe nine typical cases involving forensically relevant flies on human remains found indoors in southern Finland. Eggs, larvae and puparia were reared to adult stage and determined to species. Of the five species found the most common were Lucilia sericata Meigen, Calliphora vicina Robineau-Desvoidy and Protophormia terraenovae Robineau-Desvoidy. The flesh fly Sarcophaga caerulescens Zetterstedt is reported for the first time to colonize human cadavers inside houses and a COI gene sequence based DNA barcode is provided for it to help facilitate identification in the future. Fly biology, colonization speed and the significance of indoors forensic entomological evidence are discussed. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  6. Penetrating and Intrastromal Corneal Arcuate Incisions in Rabbit and Human Cadaver Eyes: Manual Diamond Blade and Femtosecond Laser-Created Incisions.

    Science.gov (United States)

    Gray, Brad; Binder, Perry S; Huang, Ling C; Hill, Jim; Salvador-Silva, Mercedes; Gwon, Arlene

    2016-07-01

    To compare morphologic differences between freehand diamond or femtosecond laser-assisted penetrating and intrastromal arcuate incisions. Freehand diamond blade, corneal arcuate incisions (180° apart, 60° arc lengths) and 150 kHz femtosecond laser (80% scheimpflug pachymetry depth corneal thickness) arcuate incisions were performed in rabbits. Intrastromal arcuate incisions (100 μm above Descemet's membrane, 100 μm below epithelium) were performed in rabbit corneas (energy 1.2 μJ, spot line separation 3 × 3 μm, 90° side cut angle). Eyes were examined by slit lamp and light microscopy up to 47 days post-procedure. Freehand diamond blade penetrating incisions, and femtosecond laser penetrating and intrastromal arcuate incisions (energy 1.8 μJ, spot line separation 2 × 2 μm) were performed in cadaver eyes. Optical coherence tomography was performed immediately after surgery and the corneas were fixed for light scanning and transmission electron microscopy. The rabbit model showed anterior stromal inflammation with epithelial hyperplasia in penetrating blade and laser penetrating wounds. The laser intrastromal and penetrating incisions showed localized constriction of the stromal layers of the cornea near the wound. In cadaver eyes, penetrating wound morphology was similar between blade and laser whereas intrastromal wounds did not affect the cornea above or below incisions. Penetrating femtosecond laser arcuate incisions have more predictable and controlled outcomes shown by less post-operative scarring than incisions performed with a diamond blade. Intrastromal incisions do not affect uncut corneal layers as demonstrated by histopathology. The femtosecond laser has significant advantages in its ability to make intrastromal incisions which are not achievable by traditional freehand or mechanical diamond blades.

  7. Insects (Diptera) associated with cadavers at the Institute of Legal Medicine in Pernambuco, Brazil: implications for forensic entomology.

    Science.gov (United States)

    Oliveira, Tatiana Costa; Vasconcelos, Simao Dias

    2010-05-20

    Increasing rates of unsolved homicides in Brazil prompt the need for applied entomological data to be used as a complementary tool by criminal investigators. In that context, we analyzed the occurrence of forensically important insect species (Order Diptera) on 14 cadavers taken into the Institute of Legal Medicine (ILM), in Pernambuco, Brazil, according to the conditions of the body and the pattern of colonisation by insects. Simultaneously, we surveyed the diversity of insects in the surrounding environment using bait traps. Five species were present on cadavers: Chrysomya albiceps, Chrysomya megacephala and Cochliomyia macellaria (Calliphoridae), Oxysarcodexia riograndensis and Ravinia belforti (Sarcophagidae). A total of 4689 adult insects belonging to 24 species of seven dipteran families (Calliphoridae, Sarcophagidae, Muscidae, Fanniidae, Phoridae, Anthomyiidae and Stratiomyidae) was collected at the ILM premises. C. albiceps was the most frequent species on the corpses and the most abundant in the traps. Species referred to as of forensic importance, such as Lucilia eximia, Chrysomya putoria, Oxysarcodexia modesta and Ophyra chalcogaster were collected on traps, but not on cadavers. There seems to be a limited colonisation of cadavers at the scene of the death, despite the ubiquity of necrophagous species in the area. The results contribute to differentiate between species that are involved in decomposition and those found in and around the mortuary installations of the ILM, thus providing potential clues about the locality of death and the post-mortem interval.

  8. Human radicular veins : regulation of venous reflux in the absence of valves

    NARCIS (Netherlands)

    van der Kuip, M; Hoogland, P V; Groen, R J

    1999-01-01

    In the literature it is generally assumed that venous reflux within the radicular veins is prevented by the presence of bicuspid valves and narrowing of the transdural part of these vessels. Recently, we performed a human cadaver study of the internal vertebral venous plexus. Surprisingly, a large

  9. Three Software Tools for Viewing Sectional Planes, Volume Models, and Surface Models of a Cadaver Hand.

    Science.gov (United States)

    Chung, Beom Sun; Chung, Min Suk; Shin, Byeong Seok; Kwon, Koojoo

    2018-02-19

    The hand anatomy, including the complicated hand muscles, can be grasped by using computer-assisted learning tools with high quality two-dimensional images and three-dimensional models. The purpose of this study was to present up-to-date software tools that promote learning of stereoscopic morphology of the hand. On the basis of horizontal sectioned images and outlined images of a male cadaver, vertical planes, volume models, and surface models were elaborated. Software to browse pairs of the sectioned and outlined images in orthogonal planes and software to peel and rotate the volume models, as well as a portable document format (PDF) file to select and rotate the surface models, were produced. All of the software tools were downloadable free of charge and usable off-line. The three types of tools for viewing multiple aspects of the hand could be adequately employed according to individual needs. These new tools involving the realistic images of a cadaver and the diverse functions are expected to improve comprehensive knowledge of the hand shape. © 2018 The Korean Academy of Medical Sciences.

  10. Ability of paramedics to perform endotracheal intubation during continuous chest compressions: a randomized cadaver study comparing Pentax AWS and Macintosh laryngoscopes.

    Science.gov (United States)

    Truszewski, Zenon; Czyzewski, Lukasz; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Madziala, Marcin; Szarpak, Lukasz

    2016-09-01

    The aim of the trial was to compare the time parameters for intubation with the use of the Macintosh (MAC) laryngoscope and Pentax AWS-S100 videolaryngoscope (AWS; Pentax Corporation, Tokyo, Japan) with and without chest compression (CC) by paramedics during simulated cardiopulmonary resuscitation in a cadaver model. This was a randomized crossover cadaver trial. Thirty-five paramedics with no experience in videolaryngoscopy participated in the study. They performed intubation in two emergency scenarios: scenario A, normal airway without CC; scenario B, normal airway with continuous CC. The median time to first ventilation with the use of the AWS and the MAC was similar in scenario A: 25 (IQR, 22-27) seconds vs. 24 (IQR, 22.5-26) seconds (P=.072). A statistically significant difference in TTFV between AWS and MAC was noticed in scenario B (P=.011). In scenario A, the first endotracheal intubation (ETI) attempt success rate was achieved in 97.1% with AWS compared with 94.3% with MAC (P=.43). In scenario B, the success rate after the first ETI attempt with the use of the different intubation methods varied and amounted to 88.6% vs. 77.1% for AWS and MAC, respectively (P=.002). The Pentax AWS offered a superior glottic view as compared with the MAC laryngoscope, which was associated with a higher intubation rate and a shorter intubation time during an uninterrupted CC scenario. However, in the scenario without CC, the results for AWS and MAC were comparable. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Advanced surgical skills for exposure in trauma: a new surgical skills cadaver course for surgery residents and fellows.

    Science.gov (United States)

    Kuhls, Deborah A; Risucci, Donald A; Bowyer, Mark W; Luchette, Fred A

    2013-02-01

    Surgical education is changing owing to workforce and economic demands. Simulation and other technical teaching methods are used to acquire skills transferable to the operating room. Operative management of traumatic injuries has declined, making it difficult to acquire and maintain competence. The ASSET course was developed by the Committee on Trauma's Surgical Skills Committee to fill a surgical skills need in resident and fellow education. Using a human cadaver, standardized rapid exposure of vital structures in the extremities, neck, thorax, abdomen, retroperitoneum, and pelvis is taught. A retrospective analysis of 79 participants in four ASSET courses was performed. Operative experience data were collected, and self-efficacy questionnaires (SEQs) were administered before and after the course. Course evaluations and instructor evaluation data were analyzed. Student's and paired samples t tests as well as analysis of variance and Spearman ρ correlation coefficient analysis were performed using α at p ASSET course would teach new surgical techniques and that learner self-assessed ability would improve. Participants included 27 PGY-4, 20 PGY-5, 24 PGY-6 or PGY-7 and PGY-8 at other levels of training. Self-assessed confidence improved in all body regions (p knowledge rated at 4.8 and learning new techniques at 4.72. A standardized cadaver-based surgical exposures course offered to senior surgical residents adds new surgical skills and improves participant self-assessed ability to perform emergent surgical exposure of vital structures.

  12. Primer registro de artropodofauna cadavérica en sustratos humanos y animales en San Juan, Argentina First record of cadaverous arthropod fauna in human and animal substrates in San Juan, Argentina

    Directory of Open Access Journals (Sweden)

    Fernando H. Aballay

    2008-12-01

    Full Text Available En el presente trabajo se estudiaron los artrópodos carroñeros que acudieron a cadáveres de vertebrados al aire libre en la provincia de San Juan, Argentina. El objetivo fue inventariar la composición específica de la artropodofauna cadavérica, asociada a diferentes sustratos de vertebrados en descomposición. Se colectaron muestras de artrópodos sobre restos animales y humanos en condiciones de campo y sobre cadáveres de cerdos domésticos colocados al aire libre bajo condiciones controladas. Se registraron, por primera vez para la provincia de San Juan, 40 especies de artropodofauna tanatológica incluidas en cuatro órdenes y 15 familias. Se incorpora, como primera cita para la fauna forense argentina, un necrófago: Megelenophorus americanus Lacordaire (Coleoptera: Tenebrionidae, y tres necrófilas: Polybia ruficeps Schrottky (Hymenoptera: Vespidae, Pheidole bergi Mayr (Hymenoptera, Formicidae, Myrmicinae y Ectatomma brunneum Smith (Hymenoptera, Formicidae, Ponerinae. Se citan 18 especies necrófagas, 18 necrófilas, una omnívora y seis oportunistas sobre siete diferentes sustratos cadavéricos de vertebrados. Se brindan nuevos registros de distribución de 18 especies de insectos. Se confirma la estacionalidad invernal de Callíphora vicina Robineau-Desvoidy (Diptera: Calliphoridae.In order to determine the specific composition of cadaverous arthropod fauna associated to different decomposing vertebrate substrates, we studied the carrion arthropods that feed on outdoor carcasses in San Juan province, Argentina. Arthropods were collected on animal and human remains in the field and on carcasses of domestic pig placed outdoors under controlled conditions. Forty species of carrion arthropods belonging to four orders and 15 families were recorded for the first time in this province. We present the first record of forensic fauna in Argentina of the necrophagous species Megelenophorus americanus (Coleoptera: Tenebrionidae and three

  13. Initial insights into bacterial succession during human decomposition.

    Science.gov (United States)

    Hyde, Embriette R; Haarmann, Daniel P; Petrosino, Joseph F; Lynne, Aaron M; Bucheli, Sibyl R

    2015-05-01

    Decomposition is a dynamic ecological process dependent upon many factors such as environment, climate, and bacterial, insect, and vertebrate activity in addition to intrinsic properties inherent to individual cadavers. Although largely attributed to microbial metabolism, very little is known about the bacterial basis of human decomposition. To assess the change in bacterial community structure through time, bacterial samples were collected from several sites across two cadavers placed outdoors to decompose and analyzed through 454 pyrosequencing and analysis of variable regions 3-5 of the bacterial 16S ribosomal RNA (16S rRNA) gene. Each cadaver was characterized by a change in bacterial community structure for all sites sampled as time, and decomposition, progressed. Bacteria community structure is variable at placement and before purge for all body sites. At bloat and purge and until tissues began to dehydrate or were removed, bacteria associated with flies, such as Ignatzschineria and Wohlfahrtimonas, were common. After dehydration and skeletonization, bacteria associated with soil, such as Acinetobacter, were common at most body sites sampled. However, more cadavers sampled through multiple seasons are necessary to assess major trends in bacterial succession.

  14. Hoffa's recess: incidence, morphology and differential diagnosis of the globular-shaped cleft in the infrapatellar fat pad of the knee on MRI and cadaver dissections

    International Nuclear Information System (INIS)

    Vahlensieck, M.; Linneborn, G.; Schild, H.H.; Schmidt, H.-M.

    2002-01-01

    We frequently observed a fluid-like indentation at the inferior posterior margin of Hoffa's fat pad of the knee and sought to establish the incidence and differential diagnostic criteria of this cleft. In total, 133 MRI studies and 35 cadaver specimens were analyzed for the location, size, and shape of clefts at the inferior posterior margin of Hoffa's fat pad. The incidence of a fluid-like ovoid cleft on MR images was 13.5% and in cadavers 14.3%. The cleft was located just below the insertion of the infrapatellar synovial fold (plica synovialis infrapatellaris, ligamentum mucosum). More linear-shaped indentations at the posterior margin were visible in all patients and cadavers due to the horizontal course of the alar folds. A fluid-filled indentation within the inferior posterior margin of Hoffa's fat pad has to be expected in more than 10% of knee studies and should not be confused with tumors like ganglion cysts. We term this cleft the infrahoffatic recess. One hypothesis of its origin concerns the embryological regression process of the infrapatellar membrane into the infrapatellar synovial fold. It should not be confused with linear clefts due to the alar folds. (orig.)

  15. Preliminarily measurement and analysis of sawing forces in fresh cadaver mandible using reciprocating saw for reality-based haptic feedback.

    Science.gov (United States)

    Yua, Dedong; Zhengb, Xiaohu; Chenc, Ming; Shend, Steve G F

    2012-05-01

    The aim of the study was to preliminarily measure and analyze the cutting forces in fresh Chinese cadaver mandible using a clinically widely used reciprocating saw for reality-based haptic feedback. Eight mandibles were taken from fresh Chinese cadavers, 4 females and 4 males, aged between 59 and 95 years. A set of sawing experiments, using a surgery Stryker micro-reciprocating saw and Kistler piezoelectric dynamometer, was carried out by a CNC machining center. Under different vibration frequencies of saw and feeding rates measured from orthognathic surgery, sawing forces were recorded by a signal acquisition system. Remarkably different sawing forces were measured from different cadavers. Feed and vibration frequency of the reciprocating saw could determine the cutting forces only on 1 body. To reduce the impact of bone thickness changes on the cutting force measurements, all the cutting force data should be converted to the force of unit cutting length. The vibration frequency of haptic feedback system is determined by main cutting forces. Fast Fourier transform method can be used to calculate the frequency of this system. To simulate surgery in higher fidelity, all the sawing forces from the experiment should be amended by experienced surgeons before use in virtual reality surgery simulator. Sawing force signals of different ages for force feedback were measured successfully, and more factors related to the bone mechanical properties, such as bone density, should be concerned in the future.

  16. Histological, magnetic resonance imaging, and discographic findings on cervical disc degeneration in cadaver spines. A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Yuichiro [Juntendo Univ., Tokyo (Japan). School of Medicine

    1995-11-01

    A total of 210 cervical intervertebral discs were taken at autopsy from 36 cadavers, and underwent both magnetic resonance imaging (MRI) and discography to compare their diagnostic efficacies for investigating degenerative changes in the cervical spine. The age of the subjects had ranged from 43 to 92 years with an average of 68.1 years. Following the autopsy, MRI and discography were performed on the excised cervical spinal column, and the specimen was then prepared for histological examination. The findings were compared with those of the lumbar spine that had previously been reported by Yasuma et al. on 1238 lumbar discs from 197 cadavers ranging in age from 11 to 92 years. The results were as follows: Low intensity in the T2-weighted MRI was well correlated with histological degeneration in the cervical disc. The rate of appearance of the posterior protrusion of the cervical disc on the MRI was in accordance with the degree of histological disc degeneration, but it did not always correspond with histological posterior protrusion. There was a remarkably high incidence for false-positive posterior protrusion on the MRI, which should be kept in mind on reading the MRI. In the comparison of the MRI with the discography, a certain positive correlation was found as for disc degeneration, but not in complete accordance. There was a considerable difference in the patterns of degeneration and in posterior protrusion of the discs between the cervical spine and the lumbar spine. The posterior protrusion in the cervical disc was more likely related to horizontal fissure and hyalinization of the posterior annulus, while posterior protrusion in the lumbar disc was often related to reversed orientation of the bundles and myxomatous degeneration of the posterior annulus. This difference was attributed to the difference in the mechanical properties of the cervical and lumbar spines. (author).

  17. Histological, magnetic resonance imaging, and discographic findings on cervical disc degeneration in cadaver spines. A comparative study

    International Nuclear Information System (INIS)

    Maruyama, Yuichiro

    1995-01-01

    A total of 210 cervical intervertebral discs were taken at autopsy from 36 cadavers, and underwent both magnetic resonance imaging (MRI) and discography to compare their diagnostic efficacies for investigating degenerative changes in the cervical spine. The age of the subjects had ranged from 43 to 92 years with an average of 68.1 years. Following the autopsy, MRI and discography were performed on the excised cervical spinal column, and the specimen was then prepared for histological examination. The findings were compared with those of the lumbar spine that had previously been reported by Yasuma et al. on 1238 lumbar discs from 197 cadavers ranging in age from 11 to 92 years. The results were as follows: Low intensity in the T2-weighted MRI was well correlated with histological degeneration in the cervical disc. The rate of appearance of the posterior protrusion of the cervical disc on the MRI was in accordance with the degree of histological disc degeneration, but it did not always correspond with histological posterior protrusion. There was a remarkably high incidence for false-positive posterior protrusion on the MRI, which should be kept in mind on reading the MRI. In the comparison of the MRI with the discography, a certain positive correlation was found as for disc degeneration, but not in complete accordance. There was a considerable difference in the patterns of degeneration and in posterior protrusion of the discs between the cervical spine and the lumbar spine. The posterior protrusion in the cervical disc was more likely related to horizontal fissure and hyalinization of the posterior annulus, while posterior protrusion in the lumbar disc was often related to reversed orientation of the bundles and myxomatous degeneration of the posterior annulus. This difference was attributed to the difference in the mechanical properties of the cervical and lumbar spines. (author)

  18. Comparison of Ventilation With One-Handed Mask Seal With an Intraoral Mask Versus Conventional Cuffed Face Mask in a Cadaver Model: A Randomized Crossover Trial.

    Science.gov (United States)

    Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D

    2017-01-01

    We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; Pcadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  19. Anatomy and Humanity: Examining the Effects of a Short Documentary Film and First Anatomy Laboratory Experience on Medical Students

    Science.gov (United States)

    Dosani, Farah; Neuberger, Lindsay

    2016-01-01

    Medical students begin their education inside a laboratory dissecting cadavers to learn human gross anatomy. Many schools use the course experience as a way to instill empathy and some have begun integrating video and recorded interviews with body donors to humanize the experience, but their impact has yet to be measured. This study examines the…

  20. Comparison of reliability of five patellar position indices at various stifle joint angles in pelvic limbs obtained from cadavers of red foxes (Vulpes vulpes)

    DEFF Research Database (Denmark)

    Miles, James E; Nielsen, Dorte H; Jensen, Bente Rona

    2012-01-01

    To compare 5 patellar position indices at various stifle joint angles in cadavers of red foxes, determine measurement reliability, and assess the suitability of these indices for clinical use.......To compare 5 patellar position indices at various stifle joint angles in cadavers of red foxes, determine measurement reliability, and assess the suitability of these indices for clinical use....

  1. Tunical Outer Layer Plays an Essential Role in Penile Veno-occlusive Mechanism Evidenced from Electrocautery Effects to the Corpora Cavernosa in Defrosted Human Cadavers.

    Science.gov (United States)

    Hsieh, Cheng-Hsing; Huang, Yi-Ping; Tsai, Mang-Hung; Chen, Heng-Shen; Huang, Po-Cheng; Lin, Chung-Wu; Hsu, Geng-Long

    2015-12-01

    To determine the exact anatomical structure for establishing penile veno-occlusive function, we sought to conduct a hemodynamic study on defrosted human cadavers. Thirteen penises were used for this experiment, and 11 intact penises were allocated into the electrocautery group (EG, n = 6) and the ligation group (LG, n = 5). A circumcision was made on the penis to access the veins. Two #19 scalp needles were fixed in the 3 and 9 o'clock positions in the distal penis for colloid infusion and intracavernous pressure (ICP) monitoring, respectively. For the EG, the deep dorsal vein and cavernosal vein trunks were freed for 3-5 cm where at least 3 emissary veins were identified via opening Buck's fascia; these veins underwent electrocautery at 45 watts, while the ICP was maintained at 0, 50, 75, 100, 125, and 150 mmHg, respectively. For control, venous ligation was made but at the ICP of 150 mmHg. A tissue block including the emissary vein was then obtained for histological analysis. Except all in the EG and those whose ICP exceed 125 mmHg in the EG, the sinusoids of the corpora cavernosa sustained varied fulgurated fibrosis in every specimen and the severity appeared reversely commensurate with the ICP regarding sinusoidal clumping and darkish bands (P electrocautery damage to intracavernous sinusoids once the ICP reached a level corresponding to a rigid erection. The outer tunica plays an essential role in fulfilling the veno-occlusive mechanism. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Arched abdominal aorta and altered course of right ovarian vessels in a female cadaver: Clinical significance and embryological explanation

    Directory of Open Access Journals (Sweden)

    Sneha Guruprasad Kalthur

    2013-01-01

    Full Text Available Variations in the vascular origin of ovarian artery have been reported in the past. However, the reports on altered course of ovarian artery are very few. In the present paper, we discuss about multiple variations observed in formalin fixed female cadaver. The right ovarian artery was 22 cm long and ran unusually behind the inferior vena cava (IVC. The right ovarian vein drained in to right renal vein at right angle instead of draining into IVC directly. In addition, to these variations, the cadaver had arched abdominal aorta and retro-aortic left renal vein.

  3. Evaluation of diode endoscopic cyclophotocoagulation in bovine cadaver eyes.

    Science.gov (United States)

    Harrington, Jay T; McMullen, Richard J; Cullen, John M; Gilger, Brian C

    2012-09-01

    To evaluate the anterior chamber approach and energy levels for endoscopic cyclophotocoagulation (ECPC) and assess ECPC-induced tissue damage in phakic eyes of bovine cadavers. 12 bovine cadaver eyes. Angle of reach was measured in 6 eyes following placement of a curved endoscopic probe through multiple corneal incisions. In another 6 eyes, each ocular quadrant underwent ECPC at 1 of 3 energy levels (0.75, 0.90, and 1.05 J) or remained untreated. Visible effects on tissues (whitening and contraction of ciliary processes) were scored (scale of 0 [no effects] to 6 [severe effects]), and severity and extent of histologic damage to the pigmented and nonpigmented ciliary epithelium and fibromuscular stroma were each scored (scale of 0 [no effect] to 3 [severe effect]) and summed for each quadrant. Overall mean scores for 6 quadrants/treatment were calculated. Mean ± SD combined angle of reach was 148 ± 24° (range, 123 ± 23° [ventromedial] to 174 ± 11° [dorsolateral]). At the 0.75-, 0.90-, and 1.05-J levels, mean visible tissue effect scores were 3.12 ± 0.47, 3.86 ± 0.35, and 4.68 ± 0.58, respectively; mean histologic damage scores were 4.79 ± 1.38 (mild damage), 6.82 ± 1.47 (moderate damage), and 9.37 ± 1.42 (severe damage), respectively. Occasional popping noises (venting of vaporized interstitial water) were heard at the 1.05-J level. Multiple incisions were necessary to facilitate 360° ECPC treatment in bovine eyes. For ECPC in vivo, the 0.75- and 0.90-J energy levels had the potential to effectively treat the ciliary epithelium.

  4. Forced oral opening for cadavers with rigor mortis: two approaches for the myotomy on the temporal muscles.

    Science.gov (United States)

    Nakayama, Y; Aoki, Y; Niitsu, H; Saigusa, K

    2001-04-15

    Forensic dentistry plays an essential role in personal identification procedures. An adequate interincisal space of cadavers with rigor mortis is required to obtain detailed dental findings. We have developed intraoral and two directional approaches, for myotomy of the temporal muscles. The intraoral approach, in which the temporalis was dissected with scissors inserted via an intraoral incision, was adopted for elderly cadavers, females and emaciated or exhausted bodies, and had a merit of no incision on the face. The two directional approach, in which myotomy was performed with thread-wire saw from behind and with scissors via the intraoral incision, was designed for male muscular youths. Both approaches were effective to obtain a desired degree of an interincisal opening without facial damage.

  5. Porcine cadaver organ or virtual-reality simulation training for laparoscopic cholecystectomy: a randomized, controlled trial.

    Science.gov (United States)

    Van Bruwaene, Siska; Schijven, Marlies P; Napolitano, Daniel; De Win, Gunter; Miserez, Marc

    2015-01-01

    As conventional laparoscopic procedural training requires live animals or cadaver organs, virtual simulation seems an attractive alternative. Therefore, we compared the transfer of training for the laparoscopic cholecystectomy from porcine cadaver organs vs virtual simulation to surgery in a live animal model in a prospective randomized trial. After completing an intensive training in basic laparoscopic skills, 3 groups of 10 participants proceeded with no additional training (control group), 5 hours of cholecystectomy training on cadaver organs (= organ training) or proficiency-based cholecystectomy training on the LapMentor (= virtual-reality training). Participants were evaluated on time and quality during a laparoscopic cholecystectomy on a live anaesthetized pig at baseline, 1 week (= post) and 4 months (= retention) after training. All research was performed in the Center for Surgical Technologies, Leuven, Belgium. In total, 30 volunteering medical students without prior experience in laparoscopy or minimally invasive surgery from the University of Leuven (Belgium). The organ training group performed the procedure significantly faster than the virtual trainer and borderline significantly faster than control group at posttesting. Only 1 of 3 expert raters suggested significantly better quality of performance of the organ training group compared with both the other groups at posttesting (p virtual trainer group did not outperform the control group at any time. For trainees who are proficient in basic laparoscopic skills, the long-term advantage of additional procedural training, especially on a virtual but also on the conventional organ training model, remains to be proven. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  6. The Use of Specially Designed Tasks to Enhance Student Interest in the Cadaver Dissection Laboratory

    Science.gov (United States)

    Kang, Seok Hoon; Shin, Jwa-Seop; Hwang, Young-il

    2012-01-01

    Cadaver dissection is a key component of anatomy education. Unfortunately, students sometimes regard the process of dissection as uninteresting or stressful. To make laboratory time more interesting and to encourage discussion and collaborative learning among medical students, specially designed tasks were assigned to students throughout…

  7. Insects feeding on cadavers as an alternative source of human genetic material

    Directory of Open Access Journals (Sweden)

    Rafał Skowronek

    2015-03-01

    Full Text Available In some criminal cases, the use of classical sources of human genetic material is difficult or even impossible. One solution may be the use of insects, especially blowfly larvae which feed on corpses. A recent review of case reports and experimental studies available in biomedical databases has shown that insects can be a valuable source of human mitochondrial and genomic deoxyribonucleic acid (DNA, allowing for an effective analysis of hypervariable region (HVR sequences and short tandem repeat (STR profiles, respectively. The optimal source of human DNA is the crop (a part of the gut of active third-instar blowfly larvae. Pupae and insect faeces can be also used in forensic genetic practice instead of the contents of the alimentary tract.

  8. MR imaging of the ankle at 3 Tesla and 1.5 Tesla: protocol optimization and application to cartilage, ligament and tendon pathology in cadaver specimens

    International Nuclear Information System (INIS)

    Barr, Cameron; Malfair, David; Henning, Tobias D.; Steinbach, Lynne; Link, Thomas M.; Bauer, Jan S.; Ma, Benjamin

    2007-01-01

    The objective of this study was to optimize ankle joint MR imaging in volunteers at 1.5 Tesla (T) and 3.0 T, and to compare these optimized sequences concerning image quality and performance in assessing cartilage, ligament and tendon pathology in fresh human cadaver specimens. Initially our clinical ankle protocol consisting of T1-weighted (-w), fat-saturated (fs) T2-w, and short τ inversion-recovery fast spinecho (FSE) sequences was optimized at 1.5 T and 3.0 T by two radiologists. For dedicated cartilage imaging, fs-intermediate (IM)-w FSE, fs spoiled gradient echo, and balanced free-precession steady-state sequences were optimized. Using the optimized sequences, thirteen cadaver ankle joints were imaged. Four radiologists independently assessed these images concerning image quality and pathology. All radiologists consistently rated image quality higher at 3.0 T (all sequences p<0.05). For detecting cartilage pathology, diagnostic performance was significantly higher at 3.0 T (ROC-values up to 0.93 vs. 0.77; p<0.05); the fs-IM FSE sequence showed highest values among the different sequences. Average sensitivity for detecting tendon pathology was 63% at 3.0 T vs. 41% at 1.5 T and was significantly higher at 3.0 T for 2 out of 4 radiologists (p<0.05). Compared to 1.5 T, imaging of the ankle joint at 3.0 T significantly improved image quality and diagnostic performance in assessing cartilage pathology. (orig.)

  9. Porcine cadaver iris model for iris heating during corneal surgery with a femtosecond laser

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Wang, Jiang; Yan, Ying; Juhasz, Tibor; Kurtz, Ron

    2015-03-01

    Multiple femtosecond lasers have now been cleared for use for ophthalmic surgery, including for creation of corneal flaps in LASIK surgery. Preliminary study indicated that during typical surgical use, laser energy may pass beyond the cornea with potential effects on the iris. As a model for laser exposure of the iris during femtosecond corneal surgery, we simulated the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser. Additionally, ex-vivo iris heating due to femtosecond laser irradiation was measured with an infrared thermal camera (Fluke corp. Everett, WA) as a validation of the simulation.

  10. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    Science.gov (United States)

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  11. Efficacy of Dorsoradial Capsulodesis for Trapeziometacarpal Joint Instability: A Cadaver Study.

    Science.gov (United States)

    Chenoweth, Brian A; O'Mahony, Gavin D; Fitzgerald, Casey; Stoner, Julie A; O'Donoghue, Daniel L; Rayan, Ghazi M

    2017-01-01

    To test the biomechanical properties of the dorsoradial capsulodesis procedure. Six cadaveric hands were used. After exposing the trapeziometacarpal (TMC) joint, we placed Kirschner wires in the distal radius and thumb metacarpal. The rotation shear test was then performed to test the joint axial laxity, and angular measurements using Kirschner wires as reference points were documented. The dorsoradial (DR) ligament and capsule were released, followed by the intermetacarpal (IM) ligament; angular measurements were obtained. Finally, the DR capsulodesis procedure was performed, and final measurements were obtained. Comparisons were made among the various stages of ligament integrity to determine the amount of stability provided by DR capsulodesis. All cadavers demonstrated axial laxity with transection of the DR ligament; an increase in stability was obtained after DR capsulodesis. Transection of the capsule and IM ligament caused increased laxity relative to the native joint (median, 24° and 35°, respectively, on rotational testing). After we performed DR capsulodesis, rotational stability improved by a median of 41° compared with DR ligament transection, 49° compared with DR and IM ligament transection, and 18° relative to the native joint. Dorsoradial capsulodesis restores rotational stability for TMC joint after division of the DR and IM ligaments. The stability achieved was statistically significant compared with both an intact native TMC joint and induced laxity of the TMC joint. The DR capsulodesis procedure may improve rotational stability to the TMC joint. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Intrathecal Spread of Injectate Following an Ultrasound-Guided Selective C5 Nerve Root Injection in a Human Cadaver Model.

    Science.gov (United States)

    Falyar, Christian R; Abercrombie, Caroline; Becker, Robert; Biddle, Chuck

    2016-04-01

    Ultrasound-guided selective C5 nerve root blocks have been described in several case reports as a safe and effective means to anesthetize the distal clavicle while maintaining innervation of the upper extremity and preserving diaphragmatic function. In this study, cadavers were injected with 5 mL of 0.5% methylene blue dye under ultrasound guidance to investigate possible proximal and distal spread of injectate along the brachial plexus, if any. Following the injections, the specimens were dissected and examined to determine the distribution of dye and the structures affected. One injection revealed dye extended proximally into the epidural space, which penetrated the dura mater and was present on the spinal cord and brainstem. Dye was noted distally to the divisions in 3 injections. The anterior scalene muscle and phrenic nerve were stained in all 4 injections. It appears unlikely that local anesthetic spread is limited to the nerve root following an ultrasound-guided selective C5 nerve root injection. Under certain conditions, intrathecal spread also appears possible, which has major patient safety implications. Additional safety measures, such as injection pressure monitoring, should be incorporated into this block, or approaches that are more distal should be considered for the acute pain management of distal clavicle fractures.

  13. A study of the role and functions of inspectors of anatomy in South Africa

    Directory of Open Access Journals (Sweden)

    P Pillay

    2017-12-01

    Full Text Available Inspectors of anatomy are supposed to monitor and regulate the use of human tissue for teaching and research purposes. In South Africa, provincial inspectors are appointed to oversee this function. However, there is a critical shortage of such persons, and there are only three inspectors currently appointed: one in an acting capacity for KwaZulu-Natal Province, and one each for the Gauteng and Western Cape provinces, respectively. It is imperative, therefore, that the appointment of inspectors of anatomy in the other provinces be addressed urgently. The responsibilities of inspectors of anatomy towards higher-education institutions are to: (i maintain cadaver records; (ii ensure that cadavers are obtained in a legal and ethical manner; (iii carry out inspections of anatomy departments at least once a year; (iv evaluate health and safety with regard to the storage of specimens; and (v monitor cadaver procurement. This study recommends the establishment of a National Consultative Anatomy Forum to make decisions on: (i the type of consent required for donations of bodies; (ii the mechanisms for the donation of bodies for teaching and research; and (iii the treatment of unclaimed and/or unidentified bodies. In addition, the forum should advise government on policy, and provide guidelines for the donation and use of cadavers and human tissue.

  14. Return of the cadaver: Key role of anatomic dissection for plastic surgery resident training.

    Science.gov (United States)

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-07-01

    Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques.In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised.Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study.Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures.

  15. Use of necrophagous insects as evidence of cadaver relocation: myth or reality?

    Science.gov (United States)

    Gosselin, Matthias; Hedouin, Valéry

    2017-01-01

    The use of insects as indicators of post-mortem displacement is discussed in many texts, courses and TV shows, and several studies addressing this issue have been published. Although the concept is widely cited, it is poorly understood, and only a few forensic cases have successfully applied such a method. The use of necrophagous insects as evidence of cadaver relocation actually involves a wide range of biological aspects. Distribution, microhabitat, phenology, behavioral ecology, and molecular analysis are among the research areas associated with this topic. This article provides the first review of the current knowledge and addresses the potential and limitations of different methods to evaluate their applicability. This work reveals numerous weaknesses and erroneous beliefs as well as many possibilities and research opportunities. PMID:28785513

  16. Use of necrophagous insects as evidence of cadaver relocation: myth or reality?

    Directory of Open Access Journals (Sweden)

    Damien Charabidze

    2017-08-01

    Full Text Available The use of insects as indicators of post-mortem displacement is discussed in many texts, courses and TV shows, and several studies addressing this issue have been published. Although the concept is widely cited, it is poorly understood, and only a few forensic cases have successfully applied such a method. The use of necrophagous insects as evidence of cadaver relocation actually involves a wide range of biological aspects. Distribution, microhabitat, phenology, behavioral ecology, and molecular analysis are among the research areas associated with this topic. This article provides the first review of the current knowledge and addresses the potential and limitations of different methods to evaluate their applicability. This work reveals numerous weaknesses and erroneous beliefs as well as many possibilities and research opportunities.

  17. How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    DEFF Research Database (Denmark)

    Janta, Iustina; Morán, Julio; Naredo, Esperanza

    2016-01-01

    between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned......To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance...... a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1...

  18. Comparison between Hybrid III dummy and cadaver knee response in frontal impact

    OpenAIRE

    MASSON, Catherine; CAVALLERO, Claude

    2003-01-01

    Lower limb injuries frequently occur during car accidents. The purpose of this work was to compare the response of the hybrid iii lower limb with the response of cadaver lower limb subjected to similar impacts. These experiments were performed with the objective to evaluate the biofidelity, repeatability and response characteristics of the knee-femur-pelvis HIII dummy. The tests have examined the dynamic response of the knee-femur-pelvis complex to sub injury simple pendulum impacts. The expe...

  19. Opening the medial tibiofemoral compartment by pie-crusting the superficial medial collateral ligament at its tibial insertion: a cadaver study.

    Science.gov (United States)

    Roussignol, X; Gauthe, R; Rahali, S; Mandereau, C; Courage, O; Duparc, F

    2015-09-01

    Arthroscopic treatment of tears in the middle and posterior parts of the medial meniscus can be difficult when the medial tibiofemoral compartment is tight. Passage of the instruments may damage the cartilage. The primary objective of this cadaver study was to perform an arthroscopic evaluation of medial tibiofemoral compartment opening after pie-crusting release (PCR) of the superficial medial collateral ligament (sMCL) at its distal insertion on the tibia. The secondary objective was to describe the anatomic relationships at the site of PCR (saphenous nerve, medial saphenous vein). We studied 10 cadaver knees with no history of invasive procedures. The femur was held in a vise with the knee flexed at 45°, and the medial aspect of the knee was dissected. PCR of the sMCL was performed under arthroscopic vision, in the anteroposterior direction, at the distal tibial insertion of the sMCL, along the lower edge of the tibial insertion of the semi-tendinosus tendon. Continuous 300-N valgus stress was applied to the ankle. Opening of the medial tibiofemoral compartment was measured arthroscopically using graduated palpation hooks after sequential PCR of the sMCL. The compartment opened by 1mm after release of the anterior third, 2.3mm after release of the anterior two-thirds, and 3.9mm after subtotal release. A femoral fracture occurred in 1 case, after completion of all measurements. Both the saphenous nerve and the medial saphenous vein were located at a distance from the PCR site in all 10 knees. PCR of the sMCL is chiefly described as a ligament-balancing method during total knee arthroplasty. This procedure is usually performed at the joint line, where it opens the compartment by 4-6mm at the most, with some degree of unpredictability. PCR of the sMCL at its distal tibial insertion provides gradual opening of the compartment, to a maximum value similar to that obtained with PCR at the joint space. The lower edge of the semi-tendinosus tendon is a valuable landmark

  20. How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    Science.gov (United States)

    Janta, Iustina; Morán, Julio; Naredo, Esperanza; Nieto, Juan Carlos; Uson, Jacqueline; Möller, Ingrid; Bong, David; Bruyn, George A W; D Agostino, Maria Antonietta; Filippucci, Emilio; Hammer, Hilde Berner; Iagnocco, Annamaria; Terslev, Lene; González, Jorge Murillo; Mérida, José Ramón; Carreño, Luis

    2016-06-01

    To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions.

  1. Perfluoroalkyl substances in human bone: concentrations in bones and effects on bone cell differentiation.

    Science.gov (United States)

    Koskela, A; Koponen, J; Lehenkari, P; Viluksela, M; Korkalainen, M; Tuukkanen, J

    2017-07-28

    Perfluoroalkyl substances (PFAS), including two most commonly studied compounds perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA), are widely distributed environmental pollutants, used extensively earlier. Due to their toxicological effects the use of PFAS is now regulated. Based on earlier studies on PFOA's distribution in bone and bone marrow in mice, we investigated PFAS levels and their possible link to bone microarchitecture of human femoral bone samples (n = 18). Soft tissue and bone biopsies were also taken from a 49-year old female cadaver for PFAS analyses. We also studied how PFOA exposure affects differentiation of human osteoblasts and osteoclasts. PFAS were detectable from all dry bone and bone marrow samples, PFOS and PFOA being the most prominent. In cadaver biopsies, lungs and liver contained the highest concentrations of PFAS, whereas PFAS were absent in bone marrow. Perfluorononanoic acid (PFNA) was present in the bones, PFOA and PFOS were absent. In vitro results showed no disturbance in osteogenic differentiation after PFOA exposure, but in osteoclasts, lower concentrations led to increased resorption, which eventually dropped to zero after increase in PFOA concentration. In conclusion, PFAS are present in bone and have the potential to affect human bone cells partly at environmentally relevant concentrations.

  2. First survey of forensically important insects from human corpses in Shiraz, Iran.

    Science.gov (United States)

    Moemenbellah-Fard, Mohammad D; Keshavarzi, Davood; Fereidooni, Mehran; Soltani, Aboozar

    2018-02-01

    The presence of insects on human cadavers has potential judicial value in medicolegal cases. This research emphasized the important role of insects in postmortem decomposition. It was conducted to investigate the composition and abundance of insects from human corpses during autopsies in legal medicine. It was implemented in the city of Shiraz, south Iran. Insects associated with human corpses were carefully collected and put into labelled vials. They were then identified using valid taxonomic keys. Fifteen outdoor (67%) and indoor discovered cadavers were examined. All but one was covered at the time of discovery. From these several species of entomofauna played important roles in the minimum postmortem interval (minPMI) estimate. Insects included the orders of Diptera and Coleoptera. Overall, 14 different species of arthropods were identified. Within Diptera, 2 families of Sarcophagidae and Calliphoridae were present in 73% of the cases with Calliphora vicina Robineau-Desvoidy and Chrysomya albiceps Wiedemann accounting for about half of the cases. The latter family members, Calliphoridae, were more frequently (52%) collected in autumn and winter. Only 4/15 outdoor cadavers had beetles. Four species of Coleopterans; namely Dermestes frischii Kugelann, Nitidula flavomaculata Rossi, Creophilus maxillosus Linnaeus and Saprinus chalcites Illiger; were recorded for the first time from 3 corpses in Iran. The presence and diversity of different insects on human corpses could contribute to the advancement of forensic entomology knowledge and the refined estimates of minPMI in medicolegal cases. Copyright © 2017. Published by Elsevier Ltd.

  3. Management of chest deformity caused by microtia reconstruction: Comparison of autogenous diced cartilage versus cadaver cartilage graft partial filling techniques.

    Science.gov (United States)

    Go, Ju Young; Kang, Bo Young; Hwang, Jin Hee; Oh, Kap Sung

    2017-01-01

    Efforts to prevent chest wall deformity after costal cartilage graft are ongoing. In this study, we introduce a new method to prevent donor site deformation using irradiated cadaver cartilage (ICC) and compare this method to the autogenous diced cartilage (ADC) technique. Forty-two pediatric patients comprised the ADC group (n = 24) and the ICC group (n = 18). After harvesting costal cartilage, the empty perichondrial space was filled with autologous diced cartilage in the ADC group and cadaver cartilage in the ICC group. Digital photographs and rib cartilage three-dimensional computed tomography (CT) data were analyzed to compare the preventive effect of donor site deformity. We compared the pre- and postoperative costal cartilage volumes using 3D-CT and graded the volumes (grade I: 0%-25%, grade II: 25%-50%, grade III: 50%-75%, and grade IV: 75%-100%). The average follow-up period was 20 and 24 months in the ADC and ICC groups, respectively. Grade IV maintenance of previous costal cartilage volume was evident postoperatively in 22% of patients in the ADC group and 82% of patients in the ICC group. Intercostal space narrowing and chest wall depression were less in the ICC group. There were no complications or severe resorption of cadaver cartilage. ICC support transected costal ring and prevented stability loss by acting as a spacer. The ICC technique is more effective in preventing intercostal space narrowing and chest wall depression than the ADC technique. Samsung Medical Center Institution Review Board, Unique protocol ID: 2009-10-006-008. This study is also registered on PRS (ClinicalTrials.gov Record 2009-10-006). Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Desiccation and cold storage of Galleria mellonella cadavers and effects on in vivo production of Steinernema carpocapsae

    NARCIS (Netherlands)

    Wang, X.; Wang, H.; Feng, Q.Z.; Cui, X.Y.; Liu, R.Y.; Sun, Y.B.; Li, G.C.; Tan, H.; Song, D.M.; Liu, W.; Ruan, W.B.; Harvey, J.A.

    2014-01-01

    BACKGROUNDDirect application of insect cadavers infected with entomopathogenic nematodes (EPN) can successfully control target pest insects. Little is known about the effects of environmental factors (desiccation and temperature) on the production process for infective juveniles (IJ) in insects.

  5. Musical preferences and learning outcome of medical students in cadaver dissection laboratory: A Nigerian survey.

    Science.gov (United States)

    Anyanwu, G E; Nto, J N; Agu, A U; Ekezie, J; Esom, E A

    2016-11-01

    Background music has been reported to enhance learning in the cadaver dissection laboratory. This study was designed to determine the impact of various forms of musical genre and some of their characteristics on students' learning outcome in the dissection laboratory. Some selected musical genre in vocal and non-vocal forms and at different tempi and volume were played as background music (BM) to 253 Medical and Dental students during various sessions of cadaver dissection. Psychological Stress assessment was done using Psychological stress measure-9. Participants love for music, preferred musical genre and other musical characteristics were assessed. The impact of the various musical genre and their characteristics on learning was done via written examination on the region dissected during each musical session. A positive relationship was noted between students' preference for musical genre during leisure with their preference for BM during private study time (Pmusical genre on some selected learning factors. Country and Classical music gave the highest positive impact on the various learning factors in CDL followed by R&B. No significant difference was noted between the cognitive values of vocal and non-vocal music. Classical music most effectively reduced the stress induced by dissection in the CDL while Reggae and High life musical genre created a more stressful environment than regular background noise (Pmusical genre and their various characteristics. The inability to isolate the particular musical genre with these desired properties could account for the controversies in the reports of the role of music in academic environment. Copyright © 2016 Elsevier GmbH. All rights reserved.

  6. Desiccation and cold storage of Galleria mellonella cadavers and effects on in vivo production of Steinernema carpocapsae

    NARCIS (Netherlands)

    Wang, Xin; Wang, Huan; Feng, Qing-zhou; Cui, Xi-yang; Liu, Ri-yue; Sun, Yan-bo; Li, Guo-chao; Tan, Hao; Song, Dong-min; Liu, Wen; Ruan, Wei-bin; Harvey, J.A.

    2014-01-01

    BACKGROUND: Direct application of insect cadavers infected with entomopathogenic nematodes (EPN) can successfully control target pest insects. Little is known about the effects of environmental factors (desiccation and temperature) on the production process for infective juveniles (IJ) in insects.

  7. A New Composite Eyeball-Periorbital Transplantation Model in Humans: An Anatomical Study in Preparation for Eyeball Transplantation.

    Science.gov (United States)

    Siemionow, Maria; Bozkurt, Mehmet; Zor, Fatih; Kulahci, Yalcin; Uygur, Safak; Ozturk, Can; Djohan, Risal; Papay, Frank

    2018-04-01

    Vascularized composite allotransplantation offers a new hope for restoration of orbital content and perhaps vision. The aim of this study was to introduce a new composite eyeball-periorbital transplantation model in fresh cadavers in preparation for composite eyeball allotransplantation in humans. The composite eyeball-periorbital transplantation flap borders included the inferior border, outlined by the infraorbital rim; the medial border, created by the nasal dorsum; the lateral border, created by the lateral orbital rim; and the superior border, created by the superior part of the eyebrow. The pedicle of the flap included the facial artery, superficial temporal artery, and external jugular vein. The skin and subcutaneous tissues of the periorbital region were dissected and the bony tissue was reached. A coronal incision was performed and the frontal lobe of the brain was reached by means of frontal osteotomy. Ophthalmic and oculomotor nerves were also included in the flap. After a "box osteotomy" around the orbit, the dissection was completed. Methylene blue and indocyanine green injection (SPY Elite System) was performed to show the integrity of the vascular territories after facial flap harvest. Adequate venous return was observed within the flap after methylene blue dye injection. Laser-assisted indocyanine green angiography identified a well-defined vascular network within the entire composite eyeball-periorbital transplantation flap. For the first time, a novel composite eyeball-periorbital transplantation model in human cadavers was introduced. Good perfusion of the flap confirmed the feasibility of composite eyeball-periorbital transplantation in the clinical setting. Although harvesting of the flap is challenging, it introduces a new option for reconstruction of the periorbital region including the eyeball.

  8. Three-Dimensional Changes in the Midface Following Malar Calcium Hydroxyapatite Injection in a Cadaver Model.

    Science.gov (United States)

    Gatherwright, James R; Brown, Matthew S; Katira, Kristopher M; Rowe, David J

    2015-08-01

    Three-dimensional (3D) changes in the midface following malar calcium hydroxyapatite (CaHa) injection have not been systematically analyzed. The authors analyzed 3D volume changes in midface and naso-labial fold (NLF) volume, as well as lateral movement in the NLF/naso-labial crease (NLC) junction following malar injection of CaHa in a cadaver model. A single surgeon injected CaHa in the supraperiosteal plane. Sequential images were obtained with the VECTRA 3D system pre- and post-1.5- and 3-cc CaHa injections. All measurements were performed by a single examiner. Injection location was verified anatomically. Injections were performed in 16 fresh cadaver hemi-faces. Maximal increases in projection were centered on the malar injection site, with associated decreases in projection and volume in the infero-medial locations. Relative mean increases in volume of 3.16 cc and 4.94 cc were observed following the 1.5-cc and 3-cc injections, respectively. There was a relative decrease in the volume of the NLF of -0.3 cc and -0.4 cc following the 1.5- and 3-cc injections, respectively. Injection of CaHa was associated with lateral movements of the NLF-NLC junction at the level of the nasal sill, philtral columns, and oral commissure, measuring 2.7, 2.5, and 1.9 mm and 2.8, 2.9, and 2.4 mm following the 1.5- and 3-cc injections, respectively. Anatomical dissection verified the location in the supraperiosteal space and within the middle malar fat pad. Following malar CaHa injection, 3D photographic analysis showed a measureable lifting effect with recruitment of ptotic tissue and lateral movement of the NLF-NLC junction in a cadaver model. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  9. Practical training on porcine hearts enhances students' knowledge of human cardiac anatomy.

    Science.gov (United States)

    Musumeci, Giuseppe; Loreto, Carla; Mazzone, Venera; Szychlinska, Marta Anna; Castrogiovanni, Paola; Castorina, Sergio

    2014-05-01

    Historically, cadavers have been used for the study of anatomy. Nowadays, the territorial and legal limitations of this approach have led to the introduction of alternative teaching methods such as the use of practical exercise consisting of dissection and observation of animal organs. The aim of this study was to evaluate the use of practical training on animal organs compared with the traditional method of anatomy teaching, based on the dissection of human cadavers. In this study, we seek to demonstrate the usefulness of practical exercise on animal organs. This practical training was held a week after the series of lectures, thus leaving time for the students to learn and understand the topics discussed. Immediately after the lecture, all of the students completed a preliminary test to assess the immediate effect of the lecture. Immediately before the practical exercise, both control and experimental groups completed a second test to assess the effectiveness of personal study. Immediately after practical training, a third test was completed by the experimental group and the control group (no practical activity on animal organs) to highlight the added value of hands-on practice in addition to the lecture. Data obtained from statistical analysis showed a panatomy learning between control and experimental groups. Thus, the results of this study emphasize the utility of practical training on animal organs in learning and understanding anatomy, considering the limitations of the use of cadavers. Copyright © 2014 Elsevier GmbH. All rights reserved.

  10. A Technique to Perfuse Cadavers that Extends the Useful Life of Fresh Tissues: The Duke Experience

    Science.gov (United States)

    Messmer, Caroline; Kellogg, Ryan T.; Zhang, Yixin; Baiak, Andresa; Leiweke, Clinton; Marcus, Jeffrey R.; Levin, L. Scott; Zenn, Michael R.; Erdmann, Detlev

    2010-01-01

    The demand for laboratory-based teaching and training is increasing worldwide as medical training and education confront the pressures of shorter training time and rising costs. This article presents a cost-effective perfusion technique that extends the useful life of fresh tissue. Refrigerated cadavers are preserved in their natural state for up…

  11. The shape of the human lumbar vertebral canal

    OpenAIRE

    Zarzur,Edmundo

    1996-01-01

    Literature on the anatomy of the human vertebral column characterizes the shape of the lumbar vertebral canal as triangular. The purpose of the present study was to determine the precise shape of the lumbar vertebral canal. Ten lumbar vertebral columns of adult male cadavers were dissected. Two transverse sections were performed in the third lumbar vertebra. One section was performed at the level of the lower border of the ligamenta flava, and the other section was performed at the level of t...

  12. The development, assessment and validation of virtual reality for human anatomy instruction

    Science.gov (United States)

    Marshall, Karen Benn

    1996-01-01

    This research project seeks to meet the objective of science training by developing, assessing, validating and utilizing VR as a human anatomy training medium. Current anatomy instruction is primarily in the form of lectures and usage of textbooks. In ideal situations, anatomic models, computer-based instruction, and cadaver dissection are utilized to augment traditional methods of instruction. At many institutions, lack of financial resources limits anatomy instruction to textbooks and lectures. However, human anatomy is three-dimensional, unlike the one-dimensional depiction found in textbooks and the two-dimensional depiction found on the computer. Virtual reality allows one to step through the computer screen into a 3-D artificial world. The primary objective of this project is to produce a virtual reality application of the abdominopelvic region of a human cadaver that can be taken back to the classroom. The hypothesis is that an immersive learning environment affords quicker anatomic recognition and orientation and a greater level of retention in human anatomy instruction. The goal is to augment not replace traditional modes of instruction.

  13. Bilateral Tensor Fasciae Suralis Muscles in a Cadaver with Unilateral Accessory Flexor Digitorum Longus Muscle

    Directory of Open Access Journals (Sweden)

    Logan S. W. Bale

    2017-01-01

    Full Text Available Muscle variants are routinely encountered in the dissection laboratory and in clinical practice and therefore anatomists and clinicians need to be aware of their existence. Here we describe two different accessory muscles identified while performing educational dissection of a 51-year-old male cadaver. Tensor fasciae suralis, a rare muscle variant, was identified bilaterally and accessory flexor digitorum longus, a more common muscle variant, was present unilaterally. Tensor fasciae suralis and accessory flexor digitorum longus are clinically relevant muscle variants. To our knowledge, the coexistence of tensor fasciae suralis and accessory flexor digitorum longus in the same individual has not been reported in either cadaveric or imaging studies.

  14. Morphology and morphometry of the human sublingual glands in mouth floor enlargements of edentulous patients

    Directory of Open Access Journals (Sweden)

    Josiane Costa Rodrigues de SA

    2013-12-01

    Full Text Available Asymptomatic mouth floor enlargements may be observed in edentulous patients. These masses, which protrude from the mouth floor, may complicate the fitting of dentures and require surgery. Whether this "entity" may be considered an anatomical variation of the mouth floor or represent specific alterations in the sublingual gland is not known. Objective: The aim of this work is to investigate the morphological and morphometric aspects of the sublingual glands of edentulous patients with mouth floor enlargements and compare the glands of these patients with the sublingual glands of human cadavers. Material and Methods: Microscopic evaluation was performed on human sublingual glands from edentulous patients with mouth floor enlargements (n=20 and edentulous cadavers (n=20. The patients and cadavers were of similar ages. The data were compared using Mann-Whitney U, Fisher's exact and Student's t tests (p0.05. Only the variables "autolysis" and "congested blood vessels" presented statistical difference between groups (p=0.014; p=0.043. The morphometric study revealed that the volume densities of acini, ducts, stroma and adipose tissue were similar between the groups (p>0.05. CONCLUSION: The microscopic characteristics of the sublingual glands in mouth floor enlargements in edentulous patients correspond to characteristics associated with the normal aging process. The glands are not pathological and represent an age-related alteration that occurs with or without the presence of the mouth floor enlargements.

  15. Modeling the Biodynamical Response of the Human Thorax with Body Armor from a Bullet Impact

    National Research Council Canada - National Science Library

    Lobuono, John

    2001-01-01

    .... The finite element model of the human thorax is validated by comparing the model's results to experimental data obtained from cadavers wearing a protective body armor system undergoing a projectile impact...

  16. Modeling the Biodynamical Response of the Human Thorax With Body Armor From a Bullet Impact

    National Research Council Canada - National Science Library

    Lobuono, John

    2001-01-01

    .... The finite element model of the human thorax is validated by comparing the model's results to experimental data obtained from cadavers wearing a protective body armor system undergoing a projectile impact...

  17. Too fresh is unattractive! The attraction of newly emerged Nicrophorus vespilloides females to odour bouquets of large cadavers at various stages of decomposition.

    Directory of Open Access Journals (Sweden)

    Christian von Hoermann

    Full Text Available The necrophagous burying beetle Nicrophorus vespilloides reproduces on small carcasses that are buried underground to serve as food for their offspring. Cadavers that are too large to bury have previously been postulated to be important food sources for newly emerged beetles; however, the attractiveness of distinct successive stages of decomposition were not further specified. Therefore, we investigated the potential preference of newly emerged N. vespilloides females for odour bouquets of piglet cadavers at specific stages of decomposition. Analyses of walking tracks on a Kramer sphere revealed a significantly higher mean walking speed and, consequently, a higher mean total track length when beetles were confronted with odour plumes of the decomposition stages 'post-bloating', 'advanced decay' or 'dry remains' in comparison with the solvent control. Such a change of the walking speed of newly emerged N. vespilloides females indicates a higher motivation to locate such food sources. In contrast to less discriminating individuals this behaviour provides the advantage of not wasting time at unsuitable food sources. Furthermore, in the advanced decay stage, we registered a significantly higher preference of beetles for upwind directions to its specific odour plume when compared with the solvent control. Such a change to upwind walking behaviour increases the likelihood that a large cadaver will be quickly located. Our findings are of general importance for applied forensic entomology: newly emerged N. vespilloides females on large cadavers can and should be regarded as potential indicators of prolonged post mortem intervals as our results clearly show that they prefer emitted odour bouquets of later decomposition stages.

  18. Circle of willis and its variations; morphometric study in adult human cadavers

    OpenAIRE

    Raghavendra, Shirol VS, Daksha Dixit, Anil Kumar Reddy Y, Desai SP

    2014-01-01

    Background and Objectives: Circle of Willis plays a vital role in collateral circulation and redistribution of blood to all areas of the brain. Variation in circle of Willis is known to cause grave disorders like cerebrovascular disorders, subarachnoid haemorrhage, cerebral aneurysm and schizophrenia. The objectives of the present study are to study the formation and branching pattern of circle of Willis and also to study the distribution of variations. MATERIALS & Methods: The study was cond...

  19. Morphometric and Statistical Analysis of the Palmaris Longus Muscle in Human and Non-Human Primates

    Science.gov (United States)

    Aversi-Ferreira, Roqueline A. G. M. F.; Bretas, Rafael Vieira; Maior, Rafael Souto; Davaasuren, Munkhzul; Paraguassú-Chaves, Carlos Alberto; Nishijo, Hisao; Aversi-Ferreira, Tales Alexandre

    2014-01-01

    The palmaris longus is considered a phylogenetic degenerate metacarpophalangeal joint flexor muscle in humans, a small vestigial forearm muscle; it is the most variable muscle in humans, showing variation in position, duplication, slips and could be reverted. It is frequently studied in papers about human anatomical variations in cadavers and in vivo, its variation has importance in medical clinic, surgery, radiological analysis, in studies about high-performance athletes, in genetics and anthropologic studies. Most studies about palmaris longus in humans are associated to frequency or case studies, but comparative anatomy in primates and comparative morphometry were not found in scientific literature. Comparative anatomy associated to morphometry of palmaris longus could explain the degeneration observed in this muscle in two of three of the great apes. Hypothetically, the comparison of the relative length of tendons and belly could indicate the pathway of the degeneration of this muscle, that is, the degeneration could be associated to increased tendon length and decreased belly from more primitive primates to those most derivate, that is, great apes to modern humans. In conclusion, in primates, the tendon of the palmaris longus increase from Lemuriformes to modern humans, that is, from arboreal to terrestrial primates and the muscle became weaker and tending to be missing. PMID:24860810

  20. Morphometric and Statistical Analysis of the Palmaris Longus Muscle in Human and Non-Human Primates

    Directory of Open Access Journals (Sweden)

    Roqueline A. G. M. F. Aversi-Ferreira

    2014-01-01

    Full Text Available The palmaris longus is considered a phylogenetic degenerate metacarpophalangeal joint flexor muscle in humans, a small vestigial forearm muscle; it is the most variable muscle in humans, showing variation in position, duplication, slips and could be reverted. It is frequently studied in papers about human anatomical variations in cadavers and in vivo, its variation has importance in medical clinic, surgery, radiological analysis, in studies about high-performance athletes, in genetics and anthropologic studies. Most studies about palmaris longus in humans are associated to frequency or case studies, but comparative anatomy in primates and comparative morphometry were not found in scientific literature. Comparative anatomy associated to morphometry of palmaris longus could explain the degeneration observed in this muscle in two of three of the great apes. Hypothetically, the comparison of the relative length of tendons and belly could indicate the pathway of the degeneration of this muscle, that is, the degeneration could be associated to increased tendon length and decreased belly from more primitive primates to those most derivate, that is, great apes to modern humans. In conclusion, in primates, the tendon of the palmaris longus increase from Lemuriformes to modern humans, that is, from arboreal to terrestrial primates and the muscle became weaker and tending to be missing.

  1. Discectomia lombar transforaminal: estudo quantitativo em cadáveres Discectomía lumbar transforaminal: estudio cuantitativo en cadáveres Transforaminal lumbar discectomy: quantitative study in cadavers

    Directory of Open Access Journals (Sweden)

    Emiliano Neves Vialle

    2009-06-01

    Full Text Available OBJETIVO: avaliar a eficácia da discectomia lombar por via transforaminal, de modo quantitativo, em estudo experimental com cadáveres. MÉTODOS: este estudo utilizou cinco cadáveres humanos frescos, submetidos à discectomia pela via de acesso póstero-lateral nos níveis L3-L4 e L4-L5, visando remover a maior quantidade de material discal possível. Uma abordagem anterior complementar, expondo os mesmos discos intervertebrais, permitiu a remoção do material discal remanescente, para posterior comparação. RESULTADOS: em L3-L4, a remoção transforaminal do disco obteve, em média, 48% do volume total, e em L4-L5, cerca de 38%. CONCLUSÃO: apesar de segura e de fácil realização, a via transforaminal não é tão eficaz quanto à via anterior na remoção do disco intervertebral.OBJETIVO: evaluar la eficacia de la discectomía lumbar por vía transforaminal, de modo cuantitativo, en un estudio experimental con cadáveres. MÉTODOS: este estudio utilizó cinco cadáveres humanos frescos, sometidos à discectomía por vía de acceso posterolateral en los niveles L3-L4 y L4-L5, visando remover la mayor cantidad de material discal posible. Un abordaje anterior complementar, exponiendo los mismos discos intervertebrales, permitió la remoción del material discal remanente, para posterior comparación. RESULTADOS: en L3-L4, la remoción transforaminal del disco obtuvo en promedio 48% del volumen total y en L4-L5, cerca del 38%. CONCLUSIÓN: aunque segura y de fácil realización, la vía transforaminal no es tan eficaz como la vía anterior en la remoción del disco intervertebral.OBJECTIVE: to evaluate the quantitative efficacy of transforaminal lumbar discectomy, through a cadaver study. METHODS: this study used five fresh human cadavers, that underwent L3-L4 and L4-L5 posterolateral discectomy, aiming to remove as much disc material as possible. After that, the remaining disc material was removed through an anterior approach, for further

  2. Validating in vivo Raman spectroscopy of bone in human subjects

    Science.gov (United States)

    Esmonde-White, Francis W. L.; Morris, Michael D.

    2013-03-01

    Raman spectroscopy can non-destructively measure properties of bone related to mineral density, mineral composition, and collagen composition. Bone properties can be measured through the skin in animal and human subjects, but correlations between the transcutaneous and exposed bone measurements have only been reported for human cadavers. In this study, we examine human subjects to collect measurements transcutaneously, on surgically exposed bone, and on recovered bone fragments. This data will be used to demonstrate in vivo feasibility and to compare transcutaneous and exposed Raman spectroscopy of bone. A commercially available Raman spectrograph and optical probe operating at 785 nm excitation are used for the in vivo measurements. Requirements for applying Raman spectroscopy during a surgery are also discussed.

  3. Investigation of index finger triggering force using a cadaver experiment: Effects of trigger grip span, contact location, and internal tendon force.

    Science.gov (United States)

    Chang, Joonho; Freivalds, Andris; Sharkey, Neil A; Kong, Yong-Ku; Mike Kim, H; Sung, Kiseok; Kim, Dae-Min; Jung, Kihyo

    2017-11-01

    A cadaver study was conducted to investigate the effects of triggering conditions (trigger grip span, contact location, and internal tendon force) on index finger triggering force and the force efficiency of involved tendons. Eight right human cadaveric hands were employed, and a motion simulator was built to secure and control the specimens. Index finger triggering forces were investigated as a function of different internal tendon forces (flexor digitorum profundus + flexor digitorum superficialis = 40, 70, and 100 N), trigger grip spans (40, 50, and 60 mm), and contact locations between the index finger and a trigger. Triggering forces significantly increased when internal tendon forces increased from 40 to 100 N. Also, trigger grip spans and contact locations had significant effects on triggering forces; maximum triggering forces were found at a 50 mm span and the most proximal contact location. The results revealed that only 10-30% of internal tendon forces were converted to their external triggering forces. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Stiffness of the ligaments of the human wrist joint

    NARCIS (Netherlands)

    Savelberg, H.H.C.M.; Kooloos, J.G.M.; Huiskes, H.W.J.; Kauer, J.M.G.

    1992-01-01

    The stiffnesses of the superficial ligaments of 14 human cadaver wrist joints have been determined. In these experiments the tested, fresh-frozen carpal joints are divided into a number of bone-ligament-bone complexes, which are loaded in a tensile testing machine at a rate of 66% of the ligaments'

  5. Comparison of fresh-frozen cadaver and high-fidelity virtual reality simulator as methods of laparoscopic training.

    Science.gov (United States)

    Sharma, Mitesh; Horgan, Alan

    2012-08-01

    The aim of this study was to compare fresh-frozen cadavers (FFC) with a high-fidelity virtual reality simulator (VRS) as training tools in minimal access surgery for complex and relatively simple procedures. A prospective comparative face validity study between FFC and VRS (LAP Mentor(™)) was performed. Surgeons were recruited to perform tasks on both FFC and VRS appropriately paired to their experience level. Group A (senior) performed a laparoscopic sigmoid colectomy, Group B (intermediate) performed a laparoscopic incisional hernia repair, and Group C (junior) performed basic laparoscopic tasks (BLT) (camera manipulation, hand-eye coordination, tissue dissection and hand-transferring skills). Each subject completed a 5-point Likert-type questionnaire rating the training modalities in nine domains. Data were analysed using nonparametric tests. Forty-five surgeons were recruited to participate (15 per skill group). Median scores for subjects in Group A were significantly higher for evaluation of FFC in all nine domains compared to VRS (p < 0.01). Group B scored FFC significantly better (p < 0.05) in all domains except task replication (p = 0.06). Group C scored FFC significantly better (p < 0.01) in eight domains but not on performance feedback (p = 0.09). When compared across groups, juniors accepted VRS as a training model more than did intermediate and senior groups on most domains (p < 0.01) except team work. Fresh-frozen cadaver is perceived as a significantly overall better model for laparoscopic training than the high-fidelity VRS by all training grades, irrespective of the complexity of the operative procedure performed. VRS is still useful when training junior trainees in BLT.

  6. Radiofrequency-activated PMMA-augmentation through cannulated pedicle screws: A cadaver study to determine the biomechanical benefits in the osteoporotic spine.

    Science.gov (United States)

    Karius, T; Deborre, C; Wirtz, D C; Burger, C; Prescher, A; Fölsch, A; Kabir, K; Pflugmacher, R; Goost, H

    2017-01-01

    PMMA-augmentation of pedicle screws strengthens the bone-screw-interface reducing cut-out risk. Injection of fluid cement bears a higher risk of extravasation, with difficulty of application because of inconsistent viscosity and limited injection time. To test a new method of cement augmentation of pedicle screws using radiofrequency-activated PMMA, which is suspected to be easier to apply and have less extravasations. Twenty-seven fresh-frozen human cadaver lumbar spines were divided into 18 osteoporotic (BMD ≤ 0.8 g/cm2) and 9 non-osteoporotic (BMD > 0.8 g/cm2) vertebral bodies. Bipedicular cannulated pedicle screws were implanted into the vertebral bodies; right screws were augmented with ultra-high viscosity PMMA, whereas un-cemented left pedicle screws served as negative controls. Cement distribution was controlled with fluoroscopy and CT scans. Axial pullout forces of the screws were measured with a material testing machine, and results were analyzed statistically. Fluoroscopy and CT scans showed that in all cases an adequately big cement depot with homogenous form and no signs of extravasation was injected. Pullout forces showed significant differences (p < 0.001) between the augmented and non-augmented pedicle screws for bone densities below 0.8 g/cm2 (661.9 N ± 439) and over 0.8 g/cm2 (744.9 N ± 415). Pullout-forces were significantly increased in osteoporotic as well as in non-osteoporotic vertebral bodies without a significant difference between these groups using this standardized, simple procedure with increased control and less complications like extravasation.

  7. Chiasma crurale: intersection of the tibialis posterior and flexor digitorum longus tendons above the ankle. Magnetic resonance imaging-anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M. [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Institut fuer Diagnostische Radiologie, Zurich (Switzerland); Gheno, Ramon; Nico, Marcelo A.C.; Trudell, Debra J.; Resnick, Donald [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Haghighi, Parviz [VA San Diego Medical Center, Department of Pathology, San Diego, CA (United States)

    2010-06-15

    To determine the precise anatomy and magnetic resonance (MR) imaging appearance of the chiasma crurale in cadavers, paying special attention to degenerative changes Twelve fresh human ankles were harvested from 11 nonembalmed cadavers (mean age at death 77 years) and used according to institutional guidelines. MR imaging and MR tenography were used to investigate the anatomy of the chiasma crurale using proton density-weighted sequences. The gross anatomy of the chiasma crurale was evaluated and compared to the MR imaging findings. Histology was used to elucidate further the structure of the chiasma crurale. Above the chiasma, five specimens had a small amount of fat tissue between the tibialis posterior and flexor digitorum longus tendon. In all specimens both tendons had a sheath below the chiasma but not above it. At the central portion of the chiasma there was no soft tissue between the tendons, except in two specimens that showed an anatomic variant consisting of a thick septum connecting the tibial periosteum and the deep transverse fascia of the leg. In MR images, eight specimens showed what were believed to be degenerative changes in the tendons at the level of the chiasma. However, during gross inspection and histologic analysis of the specimens, there was no tendon degeneration visible. At the central portion of the chiasma, there is no tissue between the tibialis posterior and flexor digitorum longus tendons unless there is an anatomic variant. At the chiasma crurale, areas with irregular tendon surfaces are normal findings and are not associated with tendon degeneration (fraying). (orig.)

  8. Anatomy of the Human Subthalamic Nucleus: A Combined Morphometric Study

    Directory of Open Access Journals (Sweden)

    Ioannis Mavridis

    2013-01-01

    Full Text Available Purpose. Our purpose was to provide a combined clinically oriented study focused on the detailed anatomy of the human STN, with great respect to its targeting. Methods. For our imaging study, we used cerebral magnetic resonance images (MRIs from 26 neurosurgical patients and for our anatomic study 32 cerebral hemispheres from 18 normal brains from cadaver donors. We measured and analyzed the STN dimensions (based on its stereotactic coordinates. Results. At stereotactic level Z=-4, the STN length was 7.7 mm on MRIs and 8.1 mm in anatomic specimens. Its width was 6 mm on MRIs and 6.3 mm in anatomic specimens. The STN was averagely visible in 3.2 transverse MRI slices and its maximum dimension was 8.5 mm. The intercommissural distance was 26.3 mm on MRIs and 27.3 mm in anatomic specimens. We found statistically significant difference of the STN width and length between individuals <60 and ≥60 years old. Conclusion. The identification of the STN limits was easier in anatomic specimens than on MRIs and easier on T2 compared to T1-weighted MRIs sections. STN dimensions appear slightly smaller on MRIs. Younger people have wider and longer STN.

  9. PAL(TM) 2.0 Human Anatomy Software Tool Use in Community College Traditional and Online Anatomy Laboratory Classes: Student-Perceived Learning Benefits

    Science.gov (United States)

    Kuyatt, Brian Lee

    2012-01-01

    Human anatomy courses, with laboratory, are curricular requirements in graduate medical, undergraduate nursing, and all allied health science programs. Anatomy laboratory courses engage students in hands-on activities, including human cadaver or mammalian dissection, supported by photos from textbooks, detailed plastic models or human anatomical…

  10. Five surgical maneuvers on nasal mucosa movement in cleft palate repair: A cadaver study.

    Science.gov (United States)

    Nguyen, Dennis C; Patel, Kamlesh B; Parikh, Rajiv P; Skolnick, Gary B; Woo, Albert S

    2016-06-01

    This biomechanical study aims to characterize the nasal mucosa during palatoplasty, thereby describing the soft tissue attachments at different zones and quantifying movement following their release. Palatal nasal mucosa was exposed and divided in the midline in 10 adult cadaver heads. Five consecutive maneuvers were performed: (1) elevation of nasal mucosa off the maxilla, (2) dissection of nasal mucosa from soft palate musculature, (3) separation of nasal mucosa from palatine aponeurosis, (4) release of mucosa at the pterygopalatine junction, and (5) mobilization of vomer flaps. The mucosal movements across the midline at the midpalate (MP) and posterior nasal spine (PNS) following each maneuver were measured. At the MP, maneuvers 1-4 cumulatively provided 3.8 mm (36.9%), 4.9 mm (47.6%), 6.1 mm (59.2%), and 10.3 mm, respectively. Vomer flap (10.5 mm) elevation led to mobility equivalent to that of maneuvers 1-4 (p = 0.72). At the PNS, cumulative measurements after maneuvers 1-4 were 1.3 mm (10%), 2.4 mm (18.6%), 5.7 mm (44.2%), and 12.9 mm. Here, vomer flaps (6.5 mm) provided less movement (p < 0.001). Maneuver 4 yielded the greatest amount of movement of the lateral nasal mucosa at both MP (4.2 mm, 40.8%) and PNS (7.2 mm, 55.8%). At the MP, complete release of the lateral nasal mucosa achieves as much movement as the vomer flap. At the hard-soft palate junction, the maneuvers progressively add to the movement of the lateral nasal mucosa. The most powerful step is release of attachments along the posterior aspect of the medial pterygoid. Published by Elsevier Ltd.

  11. Morphology of the human internal vertebral venous plexus : A cadaver study after latex injection in the 21-25-week fetus

    NARCIS (Netherlands)

    Groen, RJM; Grobbelaar, M; Muller, GIF; van Solinge, G; Verhoof, O; du Toit, DF; Hoogland, P.V.J.M.

    The morphology of the anterior and posterior internal vertebral venous plexus (IVVP) in human fetuses between 21-25 weeks of gestational age is described. The results are compared to the findings of a previous morphological study of the IVVP in the aged. The morphological pattern of the anterior

  12. Anatomy and relations of the infraspinatus and the teres minor muscles: a fresh cadaver dissection study.

    Science.gov (United States)

    Bacle, Guillaume; Gregoire, Jean-Marc; Patat, Frédéric; Clavert, Philippe; de Pinieux, Gonzague; Laulan, Jacky; Lakhal, Walid; Favard, Luc

    2017-02-01

    Despite their functional importance, the infraspinatus (ISP) and teres minor (TM) muscles have been little investigated. This study aimed to describe the macroscopic morphology, innervation, and inter-relations of the ISP and TM muscles. Forty fresh cadaver dissections and histologic analysis were performed. Three groups of specimens were distinguished according to the rotator cuff tendon status: (1) intact rotator cuff; (2) supraspinatus tendon tears with intact ISP tendon; and (3) both supraspinatus and ISP tendons torn. Muscle fiber organization and muscle and tendon length were recorded. ISP and TM innervation and fiber structure were studied. ISP muscles were composed of three groups of fiber organized in two planes: two superficial groups, with mean pennation angles of, respectively, 27° ± 4° and 23° ± 3° with respect to the axis of the central tendon of the underlying group. TMs were thick fusiform muscles showing a parallel organization; 26 specimens (67 %) had aponeuroses isolating the TM, with a mean length of 5.2 ± 2.7 cm. Rotator cuff lesions were associated with relatively greater ISP tendon than muscle length. Innervation of the ISP muscle comprised 2-4 main branches from the suprascapular nerve and that of the TM 1 branch from the axillary nerve. ISP muscle body morphology derives from three groups of fibers in two planes. The TM has a parallel organization. Several nerve branches innervate the ISP muscle, whereas only one supplies the TM. The limits between the two muscles bodies consist of an aponeurotic fascia in two-thirds of cases.

  13. Circle of willis and its variations; morphometric study in adult human cadavers

    Directory of Open Access Journals (Sweden)

    Raghavendra, Shirol VS, Daksha Dixit, Anil Kumar Reddy Y, Desai SP

    2014-04-01

    Full Text Available Background and Objectives: Circle of Willis plays a vital role in collateral circulation and redistribution of blood to all areas of the brain. Variation in circle of Willis is known to cause grave disorders like cerebrovascular disorders, subarachnoid haemorrhage, cerebral aneurysm and schizophrenia. The objectives of the present study are to study the formation and branching pattern of circle of Willis and also to study the distribution of variations. MATERIALS & Methods: The study was conducted on 50 adult brain specimens. Each brain was removed in one piece by dissection and the circle of Willis was observed for its formation, pattern and variations. Results: Among the 50 specimens studied, 28 cases (56% had a normal pattern of circle of Willis and variations were observed in the remaining 22 cases (44%. More number of variations was observed on the right side than on the left side. The most common variation observed was hypoplastic posterior communicating artery (7 cases, 31.8%. Posterior communicating artery was found to be the most variable vessel while middle cerebral artery was the least variable vessel. Interpretation and Conclusion: The results with respect to the circle of Willis and all its component arteries were consistent with the results in the available literature. The only exception was the increased incidence of absence of both the anterior and posterior communicating arteries. This finding is of clinical significance to neurologists and neurosurgeons in this geographical location of north Karnataka. A higher incidence of variations in the communicating arteries is likely to manifest as a higher incidence in disorders like migraine, schizophrenia and cerebrovascular disorders due to compromised collateral circulation and poor redistribution of blood.

  14. A preliminary study for non-invasive quantification of manganese in human hand bones

    International Nuclear Information System (INIS)

    Aslam; Pejovic-Milic, A; Chettle, D R; McNeill, F E; Pysklywec, M W; Oudyk, J

    2008-01-01

    Manganese (Mn) is a nutrient essential for regulating neurological and skeletal functions in the human body, but it is also toxic when humans are excessively exposed to Mn. Blood (or serum/plasma) and other body fluids reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive measurement of Mn stored in bone, using in vivo neutron activation analysis. Following feasibility studies, a first pilot study, using neutron activation analysis to measure Mn in the bones of the hand of ten healthy male human subjects, was conducted with the approval of the concerned research ethics boards. The participants of this study had no known history of exposure to Mn. Two volunteers were excluded from this study due to technical problems with their measurements. The inverse variance weighted mean value of Mn/Ca for the participants of this study is 0.12 ± 0.68 μg Mn/g Ca which is comparable within uncertainties with the estimated range of 0.16-0.78 μg Mn/g Ca and mean value of 0.63 ± 0.30 μg Mn/g Ca derived from cadaver data. It is recommended to investigate the use of the diagnostic technique for in vivo measurements of workers exposed occupationally to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. The technique needs further development to improve the precision of in vivo measurements in the non-exposed population. (note)

  15. Investigation into the visual perceptive ability of anaesthetists during ultrasound-guided interscalene and femoral blocks conducted on soft embalmed cadavers: a randomised single-blind study.

    Science.gov (United States)

    Mustafa, A; Seeley, J; Munirama, S; Columb, M; McKendrick, M; Schwab, A; Corner, G; Eisma, R; Mcleod, G

    2018-04-01

    Errors may occur during regional anaesthesia whilst searching for nerves, needle tips, and test doses. Poor visual search impacts on decision making, clinical intervention, and patient safety. We conducted a randomised single-blind study in a single university hospital. Twenty trainees and two consultants examined the paired B-mode and fused B-mode and elastography video recordings of 24 interscalene and 24 femoral blocks conducted on two soft embalmed cadavers. Perineural injection was randomised equally to 0.25, 0.5, and 1.0 ml volumes. Tissue displacement perceived on both imaging modalities was defined as 'target' or 'distractor'. Our primary objective was to test the anaesthetists' perception of the number and proportion of targets and distractors on B-mode and fused elastography videos collected during femoral and sciatic nerve block on soft embalmed cadavers. Our secondary objectives were to determine the differences between novices and experts, and between test-dose volumes, and to measure the area and brightness of spread and strain patterns. All anaesthetists recognised perineural spread using 0.25 ml volumes. Distractor patterns were recognised in 133 (12%) of B-mode and in 403 (38%) of fused B-mode and elastography patterns; P<0.001. With elastography, novice recognition improved from 12 to 37% (P<0.001), and consultant recognition increased from 24 to 53%; P<0.001. Distractor recognition improved from 8 to 31% using 0.25 ml volumes (P<0.001), and from 15 to 45% using 1 ml volumes (P<0.001). Visual search improved with fusion elastography, increased volume, and consultants. A need exists to investigate image search strategies. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  16. Anatomic Customization of Root-Analog Dental Implants With Cone-Beam CT and CAD/CAM Fabrication: A Cadaver-Based Pilot Evaluation.

    Science.gov (United States)

    Evans, Zachary P; Renne, Walter G; Bacro, Thierry R; Mennito, Anthony S; Ludlow, Mark E; Lecholop, Michael K

    2018-02-01

    Existing root-analog dental implant systems have no standardized protocols regarding retentive design, surface manipulation, or prosthetic attachment design relative to the site's unique anatomy. Historically, existing systems made those design choices arbitrarily. For this report, strategies were developed that deliberately reference the adjacent anatomy, implant and restorable path of draw, and bone density for implant and retentive design. For proof of concept, dentate arches from human cadavers were scanned using cone-beam computed tomography and then digitally modeled. Teeth of interest were virtually extracted and manipulated via computer-aided design to generate root-analog implants from zirconium. We created a stepwise protocol for analyzing and developing the implant sites, implant design and retention, and prosthetic emergence and connection all from the pre-op cone-beam data. Root-analog implants were placed at the time of extraction and examined radiographically and mechanically concerning ideal fit and stability. This study provides proof of concept that retentive root-analog implants can be produced from cone-beam data while improving fit, retention, safety, esthetics, and restorability when compared to the existing protocols. These advancements may provide the critical steps necessary for clinical relevance and success of immediately placed root-analog implants. Additional studies are necessary to validate the model prior to clinical trial.

  17. An anatomical study for localisation of zygomatic branch of facial nerve and masseteric nerve – an aid to nerve coaptation for facial reanimation surgery: A cadaver based study in Eastern India

    Directory of Open Access Journals (Sweden)

    Ratnadeep Poddar

    2017-01-01

    Full Text Available Context: In cases of chronic facial palsy, where direct neurotisation is possible, ipsilateral masseteric nerve is a very suitable motor donor. We have tried to specifically locate the masseteric nerve for this purpose. Aims: Describing an approach of localisation and exposure of both the zygomatic branch of Facial nerve and the nerve to masseter, with respect to a soft tissue reference point over face. Settings and Design: Observational cross sectional study, conducted on 12 fresh cadavers. Subjects and Methods: A curved incision was given, passing about 0.5cms in front of the tragal cartilage. A reference point “R” was pointed out. The zygomatic branch of facial nerve and masseteric nerve were dissected out and their specific locations were recorded from fixed reference points with help of copper wire and slide callipers. Statistical Analysis Used: Central Tendency measurements and Unpaired “t” test. Results: Zygomatic branch of the Facial nerve was located within a small circular area of radius 1 cm, the centre of which lies at a distance of 1.1 cms (±0.4cm in males and 0.2cm (±0.1cm in females from the point, 'R', in a vertical (coronal plane. The nerve to masseter was noted to lie within a circular area of 1 cm radius, the centre of which was at a distance of 2.5cms (±0.4cm and 1.7cms (±0.2cm from R, in male and female cadavers, respectively. Finally, Masseteric nerve's depth, from the masseteric surface was found to be 1cm (±0.1cm; male and 0.8cm (±0.1cm; female. Conclusions: This novel approach can reduce the post operative cosmetic morbidity and per-operative complications of facial reanimation surgery.

  18. Foundations for a Lifetime: A Qualitative Inquiry into the Recollection, Reconstruction and Meaning-Making Process of Cadaver Dissection

    Science.gov (United States)

    Skinner, Michelle D.

    2013-01-01

    Cadaver dissection has been a central part of the education of medical professionals for centuries. Throughout that time, anatomists have claimed that dissection is a learning experience rich with life lessons encompassing more than simply gross anatomy. Yet, no published empirical data exist of the long-term impact that dissection has on medical…

  19. Accuracy of specimen-specific nonlinear finite element analysis for evaluation of distal radius strength in cadaver material.

    Science.gov (United States)

    Matsuura, Yusuke; Kuniyoshi, Kazuki; Suzuki, Takane; Ogawa, Yasufumi; Sukegawa, Koji; Rokkaku, Tomoyuki; Takahashi, Kazuhisa

    2014-11-01

    Distal radius fracture, which often occurs in the setting of osteoporosis, can lead to permanent deformity and disability. Great effort has been directed toward developing noninvasive methods for evaluating the distal radius strength, with the goal of assessing fracture risk. The aim of this study was to evaluate distal radius strength using a finite element model and to gauge the accuracy of finite element model measurement using cadaver material. Ten wrists were obtained from cadavers with a mean age of 89.5 years at death. CT images of each wrist in an extended position were obtained. CT-based finite element models were prepared with Mechanical Finder software. Fracture on the models was simulated by applying a mechanical load to the palm in a direction parallel to the forearm axis, after which the fracture load and the site at which the fracture began were identified. For comparison, the wrists were fractured using a universal testing machine and the fracture load and the site of fracture were identified. The fracture load was 970.9 N in the finite element model group and 990.0 N in the actual measurement group. The site of the initial fracture was extra-articular to the distal radius in both groups. The finite element model was predictive for distal radius fracture when compared to the actual measurement. In this study, a finite element model for evaluation of distal radius strength was validated and can be used to predict fracture risk. We conclude that a finite element model is useful for the evaluation of distal radius strength. Knowing distal radius strength might avoid distal radius fracture because appropriate antiosteoporotic treatment can be initiated.

  20. NOTE: A preliminary study for non-invasive quantification of manganese in human hand bones

    Science.gov (United States)

    Aslam; Pejović-Milić, A.; Chettle, D. R.; McNeill, F. E.; Pysklywec, M. W.; Oudyk, J.

    2008-10-01

    Manganese (Mn) is a nutrient essential for regulating neurological and skeletal functions in the human body, but it is also toxic when humans are excessively exposed to Mn. Blood (or serum/plasma) and other body fluids reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive measurement of Mn stored in bone, using in vivo neutron activation analysis. Following feasibility studies, a first pilot study, using neutron activation analysis to measure Mn in the bones of the hand of ten healthy male human subjects, was conducted with the approval of the concerned research ethics boards. The participants of this study had no known history of exposure to Mn. Two volunteers were excluded from this study due to technical problems with their measurements. The inverse variance weighted mean value of Mn/Ca for the participants of this study is 0.12 ± 0.68 µg Mn/g Ca which is comparable within uncertainties with the estimated range of 0.16 0.78 µg Mn/g Ca and mean value of 0.63 ± 0.30 µg Mn/g Ca derived from cadaver data. It is recommended to investigate the use of the diagnostic technique for in vivo measurements of workers exposed occupationally to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. The technique needs further development to improve the precision of in vivo measurements in the non-exposed population.

  1. Right Hepatic Artery: A Cadaver Investigation and Its Clinical Significance

    Directory of Open Access Journals (Sweden)

    Usha Dandekar

    2015-01-01

    Full Text Available The right hepatic artery is an end artery and contributes sole arterial supply to right lobe of the liver. Misinterpretation of normal anatomy and anatomical variations of the right hepatic artery contribute to the major intraoperative mishaps and complications in hepatobiliary surgery. The frequency of inadvertent or iatrogenic hepatobiliary vascular injury rises with the event of an aberrant anatomy. This descriptive study was carried out to document the normal anatomy and different variations of right hepatic artery to contribute to existing knowledge of right hepatic artery to improve surgical safety. This study conducted on 60 cadavers revealed aberrant replaced right hepatic artery in 18.3% and aberrant accessory right hepatic artery in 3.4%. Considering the course, the right hepatic artery ran outside Calot’s triangle in 5% of cases and caterpillar hump right hepatic artery was seen in 13.3% of cases. The right hepatic artery (normal and aberrant crossed anteriorly to the common hepatic duct in 8.3% and posteriorly to it in 71.6%. It has posterior relations with the common bile duct in 16.7% while in 3.4% it did not cross the common hepatic duct or common bile duct. The knowledge of such anomalies is important since their awareness will decrease morbidity and help to keep away from a number of surgical complications.

  2. Cadaver-Based Simulation Increases Resident Confidence, Initial Exposure to Fundamental Techniques, and May Augment Operative Autonomy.

    Science.gov (United States)

    Kim, Steven C; Fisher, Jeremy G; Delman, Keith A; Hinman, Johanna M; Srinivasan, Jahnavi K

    Surgical simulation is an important adjunct in surgical education. The majority of operative procedures can be simplified to core components. This study aimed to quantify a cadaver-based simulation course utility in improving exposure to fundamental maneuvers, resident and attending confidence in trainee capability, and if this led to earlier operative independence. A list of fundamental surgical procedures was established by a faculty panel. Residents were assigned to a group led by a chief resident. Residents performed skills on cadavers appropriate for PGY level. A video-recorded examination where they narrated and demonstrated a task independently was then graded by attendings using standardized rubrics. Participants completed surveys regarding improvements in knowledge and confidence. The course was conducted at the Emory University School of Medicine and the T3 Laboratories in Atlanta, GA. A total of 133 residents and 41 attendings participated in the course. 133 (100%) participating residents and 32 (78%) attendings completed surveys. Resident confidence in completing the assigned skill independently increased from 3 (2-3) to 4 (3-4), p 80%), p < 0.04. Attendings were more likely to grant autonomy in the operating room after this exercise (4 [3-5]). A cadaveric skills course focused on fundamental maneuvers with objective confirmation of success is a viable adjunct to clinical operative experience. Residents were formally exposed to fundamental surgical maneuvers earlier as a result of this course. This activity improved both resident and attending confidence in trainee operative skill, resulting in increased attending willingness to grant a higher level of autonomy in the operating room. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  3. The preservation of a cadaver by a clay sealant: Implications for the disposal of nuclear fuel waste

    International Nuclear Information System (INIS)

    Lee, C.F.; Oscarson, D.W.; Cheung, S.C.H.

    1986-01-01

    This report documents a case history in which a cadaver and the associated burial objects were found well preserved after being buried for more than 2100 years in Southern China. The preservation is attributed to a layer of kaolin that surrounded the coffin and served as a barrier to water and air movement. The implications for the disposal of nuclear fuel waste are discussed

  4. Accuracy of computer-assisted template-guided autotransplantation of teeth with custom three-dimensional designed/printed surgical tooling : A cadaveric study

    NARCIS (Netherlands)

    Anssari Moin, D.; Verweij, J.P.; Waars, H.; van Merkesteyn, R.; Wismeijer, D.

    2017-01-01

    Purpose: The aim of the present cadaveric study was to assess the accuracy of computer-assisted template-guided autotransplantation of teeth with custom 3-dimensional (3D) designed/printed surgical tooling. Materials and Methods: Ten partially edentulous human mandibular cadavers were scanned using

  5. [Ultrastructure of the intima of human pial arteries in arterial hypertension].

    Science.gov (United States)

    Chertok, V M; Kotsiuba, A E; Babich, E V

    2009-01-01

    Ultrastructure of the intima of human pial arteries obtained from 5 male cadavers of practically healthy individuals and from 8 cadavers of the patients with the intravitally diagnosed grade I arterial hypertension (AH) was studied by scanning and transmission electron microscopy. AH was found to be associated with the remodeling of the intimal structural elements in the pial arteries. In most arteries, the changes were detected in the microrelief of the luminal surface and in the permeability of the vascular endothelial lining and of the subendothelial layer. During this remodeling, some endothelial cells were found in the state of structural and functional adaptation to the elevated arterial pressure, while the others were undergoing the dystrophic changes. The latter include the cells containing lipid inclusions, as well as the endothelial cells presumably in the state of apoptosis. The destruction of the intercellular junctions, the disturbances in the endothelium permeability contributed to the development of subendothelial layer edema, resulting in its significant thickening. This layer became looser and contained abundant collagen fibrils.

  6. Insulin and C-peptide in human brain neurons (insulin/C-peptide/brain peptides/immunohistochemistry/radioimmunoassay)

    International Nuclear Information System (INIS)

    Dorn, A.; Bernstein, H.G.; Rinne, A.; Hahn, H.J.; Ziegler, M.

    1983-01-01

    The regional distribution and cellular localization of insulin and C-peptide immunoreactivities were studied in human cadaver brains using the indirect immunofluorescence method, the peroxidase-antiperoxidase technique, and radioimmunoassay. Products of the immune reactions to both polypeptides were observed in most nerve cells in all areas of the brain examined. Immunostaining was mainly restricted to the cell soma and proximal dendrites. Radioimmunoassay revealed that human brain contains insulin and C-peptide in concentrations much higher than the blood, the highest being in the hypothalamus. These findings support the hypothesis that the 'brain insulin' is - at least in part - produced in the CNS. (author)

  7. Nerve supply to the internal anal sphincter differs from that to the distal rectum: an immunohistochemical study of cadavers.

    Science.gov (United States)

    Kinugasa, Yusuke; Arakawa, Takashi; Murakami, Gen; Fujimiya, Mineko; Sugihara, Kenichi

    2014-04-01

    Fecal incontinence is a common problem after anal sphincter-preserving operations. The intersphincteric autonomic nerves supplying the internal anal sphincter (IAS) are formed by the union of: (1) nerve fibers from Auerbach's nerve plexus of the most distal part of the rectum and (2) the inferior rectal branches of the pelvic plexus (IRB-PX) running along the conjoint longitudinal muscle coat. The aim of the present study is to identify the detailed morphology of nerves to the IAS. The study comprised histological and immunohistochemical evaluations of paraffin-embedded sections from a large block of anal canal from the preserved 10 cadavers. The IRB-PX came from the superior aspect of the levator ani and ran into the anal canal on the anterolateral side. These nerves contained both sympathetic and parasympathetic fibers, but the sympathetic content was much higher than in nerves from the distal rectum. All intramural ganglion cells in the distal rectum were neuronal nitric oxide synthase-positive and tyrosine hydroxylase-negative and were restricted to above the squamous-columnar epithelial junction. Parasympathetic nerves formed a lattice-like plexus in the circular smooth muscles of the distal rectum, whereas the IAS contained short, longitudinally running sympathetic and parasympathetic nerves, although sympathetic nerves were dominant. The major autonomic nerve input to the IAS seemed not to originate from the distal rectum but from the IRB-PX. Injury to the IRB-PX during surgery seemed to result in loss of innervation to the major part of the IAS.

  8. Ultrasound-guided block of sciatic and femoral nerves: an anatomical study.

    Science.gov (United States)

    Waag, Sonja; Stoffel, Michael H; Spadavecchia, Claudia; Eichenberger, Urs; Rohrbach, Helene

    2014-04-01

    The sheep is a popular animal model for human biomechanical research involving invasive surgery on the hind limb. These painful procedures can only be ethically justified with the application of adequate analgesia protocols. Regional anaesthesia as an adjunct to general anaesthesia may markedly improve well-being of these experimental animals during the postoperative period due to a higher analgesic efficacy when compared with systemic drugs, and may therefore reduce stress and consequently the severity of such studies. As a first step 14 sheep cadavers were used to establish a new technique for the peripheral blockade of the sciatic and the femoral nerves under sonographic guidance and to evaluate the success rate by determination of the colorization of both nerves after an injection of 0.5 mL of a 0.1% methylene blue solution. First, both nerves were visualized sonographically. Then, methylene blue solution was injected and subsequently the length of colorization was measured by gross anatomical dissection of the target nerves. Twenty-four sciatic nerves were identified sonographically in 12 out of 13 cadavers. In one animal, the nerve could not be ascertained unequivocally and, consequently, nerve colorization failed. Twenty femoral nerves were located by ultrasound in 10 out of 13 cadavers. In three cadavers, signs of autolysis impeded the scan. This study provides a detailed anatomical description of the localization of the sciatic and the femoral nerves and presents an effective and safe yet simple and rapid technique for performing peripheral nerve blocks with a high success rate.

  9. Tendon Interposition and Ligament Reconstruction with ECRL Tendon in the Late Stages of Kienböck’s Disease: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Nazım Karalezli

    2013-01-01

    Full Text Available Background. The optimal surgical treatment for Kienböck’s disease with stages IIIB and IV remains controversial. A cadaver study was carried out to evaluate the use of coiled extensor carpi radialis longus tendon for tendon interposition and a strip obtained from the same tendon for ligament reconstruction in the late stages of Kienböck’s disease. Methods. Coiled extensor carpi radialis longus tendon was used to fill the cavity of the excised lunate, and a strip obtained from this tendon was sutured onto itself after passing through the scaphoid and the triquetrum acting as a ligament to preserve proximal row integrity. Biomechanical tests were carried out in order to evaluate this new ligamentous reconstruction. Results. It was biomechanically confirmed that the procedure was effective against axial compression and distributed the upcoming mechanical stress to the distal row. Conclusion. Extensor carpi radialis longus tendon has not been used for tendon interposition and ligament reconstruction in the treatment of this disease before. In view of the biomechanical data, the procedure seems to be effective for the stabilization of scaphoid and carpal bones.

  10. Flexible nine-channel photodetector probe facilitated intraspinal multisite transcutaneous photobiomodulation therapy dosimetry in cadaver dogs

    Science.gov (United States)

    Piao, Daqing; Sypniewski, Lara A.; Bailey, Christian; Dugat, Danielle; Burba, Daniel J.; De Taboada, Luis

    2018-01-01

    Noninvasive photobiomodulation therapy (PBMT) of spinal cord disease remains speculative due to the lack of evidence for whether photobiomodulatory irradiances can be transcutaneously delivered to the spinal cord under a clinically acceptable PBMT surface irradiation protocol. We developed a flexible nine-channel photodetection probe for deployment within the spinal canal of a cadaver dog after hemilaminectomy to measure transcutaneously transmitted PBMT irradiance at nine sites over an eight-cm spinal canal length. The probe was built upon a 6.325-mm tubular stem, to the surface of which nine photodiodes were epoxied at approximately 1 cm apart. The photodiode has a form factor of 4.80 mm×2.10 mm×1.15 mm (length×width×height). Each photodiode was individually calibrated to deliver 1 V per 7.58 μW/cm2 continuous irradiance at 850 nm. The outputs of eight photodiodes were logged concurrently using a data acquisition module interfacing eight channels of differential analog signals, while the output of the ninth photodiode was measured by a precision multimeter. This flexible probe rendered simultaneous intraspinal (nine-site) measurements of transcutaneous PBMT irradiations at 980 nm in a pilot cadaver dog model. At a surface continuous irradiance of 3.14 W/cm2 applied off-contact between L1 and L2, intraspinal irradiances picked up by nine photodiodes had a maximum of 327.48 μW/cm2 without the skin and 5.68 μW/cm2 with the skin.

  11. Primer registro de artropodofauna cadavérica en sustratos humanos y animales en San Juan, Argentina

    Directory of Open Access Journals (Sweden)

    Fernando H. ABALLAY

    2008-01-01

    Full Text Available En el presente trabajo se estudiaron los artrópodos carroñeros que acudieron a cadáveres de vertebrados al aire libre en la provincia de San Juan, Argentina. El objetivo fue inventariar la composición específica de la artropodofauna cadavérica, asociada a diferentes sustratos de vertebrados en descomposición. Se colectaron muestras de artrópodos sobre restos animales y humanos en condiciones de campo y sobre cadáveres de cerdos domésticos colocados al aire libre bajo condiciones controladas. Se registraron, por primera vez para la provincia de San Juan, 40 especies de artropodofauna tanatológica incluidas en cuatro órdenes y 15 familias. Se incorpora, como primera cita para la fauna forense argentina, un necrófago: Megelenophorus americanus Lacordaire (Coleoptera: Tenebrionidae, y tres necrófilas: Polybia ruficeps Schrottky (Hymenoptera: Vespidae, Pheidole bergi Mayr (Hymenoptera, Formicidae, Myrmicinae y Ectatomma brunneum Smith (Hymenoptera, Formicidae, Ponerinae. Se citan 18 especies necrófagas, 18 necrófilas, una omnívora y seis oportunistas sobre siete diferentes sustratos cadavéricos de vertebrados. Se brindan nuevos registros de distribución de 18 especies de insectos. Se confirma la estacionalidad invernal de Callíphora vicina Robineau-Desvoidy (Diptera: Calliphoridae.

  12. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers

    International Nuclear Information System (INIS)

    Kalender, W.A.; Wolf, H.; Suess, C.; Gies, M.; Greess, H.; Bautz, W.A.

    1999-01-01

    We investigated approaches to reducing the dose in CT without impairing image quality. Dose can be reduced for non-circular object cross-sections without a significant increase in noise if X-ray tube current is reduced at angular tube positions where the X-ray attenuation by the patients is small. We investigated different schemes of current modulation during tube rotation by simulation and phantom measurements. Both pre-programmed sinusoidal modulation functions and attenuation-based on-line control of the tube current were evaluated. All relevant scan parameters were varied, including constraints such as the maximum modulation amplitude. A circular, an elliptical and two oval water phantoms were used. Results were validated on six cadavers. Dose reduction of 10-45 % was obtained both in simulations and in measurements for the different non-circular phantom geometries and current modulation algorithms without an increase in pixel noise values. On-line attenuation-based control yielded higher reductions than modulation by a sinusoidal curve. The maximal dose reduction predicted by simulations could not be achieved due to limits in the modulation amplitude. In cadaver studies, a reduction of typically 20-40 % was achieved for the body and about 10 % for the head. Variations of our technique are possible; a slight increase in nominal tube current for high-attenuation projections combined with attenuation-based current modulation still yields significant dose reduction, but also a reduction in the structured noise that may obscure diagnostic details. We conclude that a significant reduction in dose can be achieved by tube current modulation without compromising image quality. Attenuation-based on-line control and a modulation amplitude of at least 90 % should be employed. (orig.)

  13. Assessment of a new hydrophilic acrylic supplementary IOL for sulcus fixation in pseudophakic cadaver eyes

    Science.gov (United States)

    Reiter, N; Werner, L; Guan, J; Li, J; Tsaousis, K T; Mamalis, N; Srinivasan, S

    2017-01-01

    Purpose Management of refractive errors after cataract surgery includes spectacles or contact lens, secondary laser vision correction, intraocular lens (IOL) exchange, or piggyback lens implantation. We evaluated for the first time a single-piece hydrophilic acrylic IOL designed for supplementary sulcus fixation in postmortem pseudophakic human eyes. Methods Pseudophakic human cadaver eyes were imaged by anterior segment optical coherence tomography (AS-OCT) to assess position of the primary IOL. Eyes were prepared as per the Miyake-Apple technique. The supplementary IOL (Medicontur A4 Addon IOL family) was then inserted into the ciliary sulcus. AS-OCT and photographs from anterior and posterior views were used to assess IOL centration, tilt, and interlenticular distance from the primary IOL. Results Data were obtained from 12 eyes having primary IOLs of varying materials and designs in the bag and representing different sizes of eyes and severity of Soemmering's ring formation. The A4 Addon IOL was successfully inserted into the ciliary sulcus and was well centered in all cases. Four cases of tilt were observed on AS-OCT: three with mild tilt due to pre-existing zonular dehiscence, and one due to a localized area of Soemmering's ring formation. Interlenticular distance ranged from 0.34 to 1.24 mm and was not dependent on severity of Soemmering's ring or type of primary IOL. Conclusions The A4 Addon IOL was designed for sulcus fixation as a supplementary lens, with a large diameter, a square-shaped optic, four smooth loop haptics, and a convex–concave optical surface. It exhibited appropriate centration and interlenticular distance with different primary in-the-bag IOLs. PMID:28106890

  14. Integration of basic science and clinical medicine: the innovative approach of the cadaver biopsy project at the Boston University School of Medicine.

    Science.gov (United States)

    Eisenstein, Anna; Vaisman, Lev; Johnston-Cox, Hillary; Gallan, Alexander; Shaffer, Kitt; Vaughan, Deborah; O'Hara, Carl; Joseph, Lija

    2014-01-01

    Curricular integration has emerged as a consistent theme in medical education reform. Vertical integration of topics such as pathology offers the potential to bring basic science content into the clinical arena, but faculty/student acceptance and curricular design pose challenges for such integration. The authors describe the Cadaver Biopsy Project (CBP) at Boston University School of Medicine as a sustainable model of vertical integration. Faculty and select senior medical students obtained biopsies of cadavers during the first-year gross anatomy course (fall 2009) and used these to develop clinical cases for courses in histology (spring 2010), pathology (fall 2010-spring 2011), and radiology (fall 2011 or spring 2012), thereby linking students' first experiences in basic sciences with other basic science courses and later clinical courses. Project goals included engaging medical stu dents in applying basic science princi ples in all aspects of patient care as they acquire skills. The educational intervention used a patient (cadaver)-centered approach and small-group, collaborative, case-based learning. Through this project, the authors involved clinical and basic science faculty-plus senior medical students-in a collaborative project to design and implement an integrated curriculum through which students revisited, at several different points, the microscopic structure and pathophysiology of common diseases. Developing appropriate, measurable out comes for medical education initiatives, including the CBP, is challenging. Accumu lation of qualitative feedback from surveys will guide continuous improvement of the CBP. Documenting longer-term impact of the curricular innovation on test scores and other competency-based outcomes is an ultimate goal.

  15. Study of physical, chemical and structural effects caused by ionizing radiation and preservation on human costal cartilage

    International Nuclear Information System (INIS)

    Martinho Junior, Antonio Carlos

    2008-01-01

    Tissue Banks around the world have stored human cartilages obtained from cadaver donors for use in several kinds of reconstructive surgeries. To ensure that such tissues are not contaminated, they have been sterilized with ionizing radiation. However, high doses of gamma radiation may cause undesirable changes in the tissues, decreasing the mechanical properties of the grafts. In this work, we evaluate physical/chemical and structural changes in deep-frozen (-70 deg C) or high concentration of glycerol (> 98%) preserved costal cartilage, before and after sterilization by ionizing radiation at 3 different doses (15, 25 and 50 kGy). Samples of human costal cartilage were obtained from 20 cadaver donors ranging between 18 and 55 years old. A 60 Co irradiator was used as irradiation source. Thermogravimetry (TG), Optical Coherence Tomography (OCT) and mechanical tension and compression tests were carried out to evaluate the changes in the cartilage. Regarding the thermogravimetric results, the obtained data has shown that the TG curves have the same pattern independently of the sample irradiated or not. On the other hand, non-irradiated samples showed great variability of thermogravimetric curves among different donors and for the same donor. Concerning the mechanical tests, when cartilages were irradiated with 15 kGy, their mechanical strength to tension was increased about 24%, in both deep-froze and preserved in glycerol samples. Samples deep-frozen, when irradiated with 25 and 50 kGy, presented a decrease of their mechanical behavior smaller than those preserved in high concentrations of glycerol and irradiated with the same dose. Therefore, deep-frozen cartilages can be sterilized with doses until 50 kGy and cartilages preserved in high concentrations of glycerol can be sterilized with doses until 25 kGy without significant changes in their bio-mechanical properties.(author)

  16. Visualizing Iron Deposition in Multiple Sclerosis Cadaver Brains

    International Nuclear Information System (INIS)

    Habib, Charbel A.; Zheng Weili; Mark Haacke, E.; Webb, Sam; Nichol, Helen

    2010-01-01

    Aim: To visualize and validate iron deposition in two cases of multiple sclerosis using rapid scanning X-Ray Fluorescence (RS-XRF) and Susceptibility Weighted Imaging (SWI). Material and Methods: Two (2) coronal cadaver brain slices from patients clinically diagnosed with multiple sclerosis underwent magnetic resonance imaging (MRI), specifically SWI to image iron content. To confirm the presence of iron deposits and the absence of zinc-rich myelin in lesions, iron and zinc were mapped using RS-XRF. Results: MS lesions were visualized using FLAIR and correlated with the absence of zinc by XRF. XRF and SWI showed that in the first MS case, there were large iron deposits proximal to the draining vein of the caudate nucleus as well as iron deposits associated with blood vessels throughout the globus pallidus. Less iron was seen in association with lesions than in the basal ganglia. The presence of larger amounts of iron correlated reasonably well between RS-XRF and SWI. In the second case, the basal ganglia appeared normal and acute perivascular iron deposition was absent. Conclusion: Perivascular iron deposition is seen in some but not all MS cases, giving credence to the use of SWI to assess iron involvement in MS pathology in vivo.

  17. Anatomical variability in the trajectory of the inside-out transobturator vaginal tape technique (TVT-O)

    NARCIS (Netherlands)

    Hinoul, Piet; Vanormelingen, Linda; Roovers, Jan-Paul; de Jonge, Eric; Smajda, Stéfan

    2007-01-01

    An experimental surgical study on human cadavers was undertaken to assess variability in the trajectory followed by the needle during application of the inside-out transobturator tape suspension (TVT-O) technique. The TVT-O surgical procedures were performed on six fresh female cadavers according to

  18. Sonography of the anterior oblique ligament of the trapeziometacarpal joint: a study of cadavers and asymptomatic volunteers.

    Science.gov (United States)

    Chiavaras, Mary M; Harish, Srinivasan; Oomen, Glen; Popowich, Terry; Wainman, Bruce; Bain, James R

    2010-12-01

    The purpose of this study was to evaluate the ability of ultrasound to identify and characterize the anterior oblique ligament of the thumb in cadavers and asymptomatic volunteers. The anterior oblique ligaments of four cadaveric hands were imaged with a high-resolution transducer. The ligaments were then injected with 0.1% methylene blue using ultrasound guidance. To confirm identification of the ligament, the base of the thumb was immediately dissected, revealing the exact location of the dye. The bilateral ligaments in 40 asymptomatic adult volunteers were imaged. Surgical dissection confirmed injection of methylene blue into all cadaveric ligaments. The proximal attachment of the anterior oblique ligament was well defined in all the hands, and the distal attachment was well defined in 94% of the hands. The mean thickness of the anterior oblique ligament at the metacarpal attachment (0.7 mm), midportion (0.98 mm), and trapezial attachment (0.65 mm) did not differ significantly with respect to sex, right and left side, or hand dominance and was weakly correlated with weight, height, body mass index, and age. The length of the ligament was statistically significantly different between the dominant (10.6 mm) and nondominant (9.6 mm) hands. The volar metacarpal translation with palmar abduction stress did not differ significantly between the dominant (0.7 mm) and nondominant (0.8 mm) hands. There was no association between the degree of translation and the biologic characteristics (weight, height, body mass index, and age). High-resolution ultrasound can be used to identify and measure the thickness of the anterior oblique ligament. Dynamic ultrasound imaging can depict volar translation of the metacarpal, which may facilitate diagnosis of ligamentous injury.

  19. The use of time-of-flight camera for navigating robots in computer-aided surgery: monitoring the soft tissue envelope of minimally invasive hip approach in a cadaver study.

    Science.gov (United States)

    Putzer, David; Klug, Sebastian; Moctezuma, Jose Luis; Nogler, Michael

    2014-12-01

    Time-of-flight (TOF) cameras can guide surgical robots or provide soft tissue information for augmented reality in the medical field. In this study, a method to automatically track the soft tissue envelope of a minimally invasive hip approach in a cadaver study is described. An algorithm for the TOF camera was developed and 30 measurements on 8 surgical situs (direct anterior approach) were carried out. The results were compared to a manual measurement of the soft tissue envelope. The TOF camera showed an overall recognition rate of the soft tissue envelope of 75%. On comparing the results from the algorithm with the manual measurements, a significant difference was found (P > .005). In this preliminary study, we have presented a method for automatically recognizing the soft tissue envelope of the surgical field in a real-time application. Further improvements could result in a robotic navigation device for minimally invasive hip surgery. © The Author(s) 2014.

  20. Development and initial porcine and cadaver experience with three-dimensional printing of endoscopic and laparoscopic equipment.

    Science.gov (United States)

    del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim; Landman, Jaime

    2015-01-01

    Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (pcadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future.

  1. Raman spectroscopic analysis of human skin tissue sections ex-vivo: evaluation of the effects of tissue processing and dewaxing

    Science.gov (United States)

    Ali, Syed M.; Bonnier, Franck; Tfayli, Ali; Lambkin, Helen; Flynn, Kathleen; McDonagh, Vincent; Healy, Claragh; Clive Lee, T.; Lyng, Fiona M.; Byrne, Hugh J.

    2013-06-01

    Raman spectroscopy coupled with K-means clustering analysis (KMCA) is employed to elucidate the biochemical structure of human skin tissue sections and the effects of tissue processing. Both hand and thigh sections of human cadavers were analyzed in their unprocessed and formalin-fixed, paraffin-processed (FFPP), and subsequently dewaxed forms. In unprocessed sections, KMCA reveals clear differentiation of the stratum corneum (SC), intermediate underlying epithelium, and dermal layers for sections from both anatomical sites. The SC is seen to be relatively rich in lipidic content; the spectrum of the subjacent layers is strongly influenced by the presence of melanin, while that of the dermis is dominated by the characteristics of collagen. For a given anatomical site, little difference in layer structure and biochemistry is observed between samples from different cadavers. However, the hand and thigh sections are consistently differentiated for all cadavers, largely based on lipidic profiles. In dewaxed FFPP samples, while the SC, intermediate, and dermal layers are clearly differentiated by KMCA of Raman maps of tissue sections, the lipidic contributions to the spectra are significantly reduced, with the result that respective skin layers from different anatomical sites become indistinguishable. While efficient at removing the fixing wax, the tissue processing also efficiently removes the structurally similar lipidic components of the skin layers. In studies of dermatological processes in which lipids play an important role, such as wound healing, dewaxed samples are therefore not appropriate. Removal of the lipids does however accentuate the spectral features of the cellular and protein components, which may be more appropriate for retrospective analysis of disease progression and biochemical analysis using tissue banks.

  2. ANATOMICAL VARIATIONS OF THE GASTROCNEMIUS MUSCLE- A DISSECTION-BASED STUDY

    Directory of Open Access Journals (Sweden)

    Rajat Dutta Roy

    2017-11-01

    Full Text Available BACKGROUND In human, the bulk of the posterior compartment of the leg is formed by the gastrocnemius and the soleus muscle. The superficially-placed gastrocnemius is a bipennate muscle, but according to available literature, it exhibits numerous anatomical variations. The aim of the present study is to find out the anatomical variations of the gastrocnemius muscle in this part of Assam. MATERIALS AND METHODS The present study undertaken in the Department of Anatomy, Jorhat Medical College, from August 2014 to August 2017 included 30 lower limbs from 15 embalmed cadavers of known sexes. These cadavers were provided to the first year MBBS students for routine dissection procedure. After carrying out the dissection as per Cunningham’s Manual of Practical Anatomy, the gastrocnemius muscle was examined for its two heads of origin. Any accessory heads found were noted and recorded. RESULTS Out of the 30 lower limb specimens, 28 (93.33% limbs presented with the normal two-headed gastrocnemius muscle, while 2 (6.66% limbs (1 right and 1 left, presented with four-headed gastrocnemius muscle. Both these limbs belonged to male cadavers. CONCLUSION The precise knowledge of occurrence of multi-headed gastrocnemius muscle should be kept in mind, while performing myocutaneous flaps around the knee joint and also during limb salvage procedures or limb sparing surgery.

  3. Successful transplantation of in vitro expanded human corneal endothelial precursors to corneal endothelial surface using a nanocomposite sheet

    Directory of Open Access Journals (Sweden)

    Parikumar P

    2011-01-01

    Full Text Available Background: Though the transplantation of in vitro expanded human corneal endothelial precursors in animal models of endothelial damage by injecting into the anterior chamber has been reported, the practical difficulties of accomplishing such procedure in human patients have been a hurdle to clinical translation. Here we report the successful transplantation of in vitro expanded human corneal precursor cells to an animal eye using a transparent Nano-composite sheet and their engraftment.Materials and Methods: Human Corneal endothelial cells (HCEC were isolated from human cadaver eyes with informed consent and expanded in the lab using a sphere forming assay in a novel Thermoreversible Gelation Polymer (TGP for 26 days. HCEC obtained by sphere forming assay were seeded in a novel Nano-composite sheet, which was made of PNIPA-NC gels by in-situ, free-radical polymerization of NIPA monomer in the presence of exfoliated clay (synthetic hectorite “Laponite XLG” uniformly dispersed in aqueous media. After a further seven days in vitro culture of HCEC in the Nano-composite sheet, cells were harvested and transplanted on cadaver-bovine eyes (n=3. The cells were injected between the corneal endothelial layer and the Nano-composite sheet that had been placed prior to the injection in close proximity to the endothelial layer. After three hours, the transplanted Nano-composite sheets were removed from the bovine eyes and subjected to microscopic examination. The corneas were subjected to Histo-pathological studies along with controls. Results: HCEC formed sphere like colonies in TGP which expressed relevant markers as confirmed by RT-PCR. Microscopic studies of the Nanosheets and histopathological studies of the cornea of the Bull’s eye revealed that the HCEC got engrafted to the corneal endothelial layer of the bovine eyes with no remnant cells in the Nanosheet. Conclusion: Transplantation of in vitro expanded donor human corneal endothelial cells

  4. Assessment of Morphological Variations and its Specific Location on the Surface of Adult Human Liver in Ethiopian Cadavers University of Gondar, Bahir Dar University, Addis Ababa University, St. Paulos Medical School and Hawassa University, Ethiopia

    Directory of Open Access Journals (Sweden)

    Tsegaye Mehare

    2017-10-01

    Full Text Available Background: Liver is the second largest organ next to skin and located in right hypochondrium, epigastrium and may extend to left hypochondrium in upper abdominal cavity. It accounts 2% to 3% of total body weight of individual. Land marking for interpreting different diagnostic image and localizing lesions in the liver is commonly done by major fissures. Sound knowledge about different morphological variations which are found on the surface of liver is mandatory to have safe surgical outcome. Segments of liver were extensively researched but there are only few studies dealt with the surface variation of the liver. Therefore, this study aims to assess morphological variations and its specific location on the surface of adult human liver in Ethiopian cadaver. Methodology: Institutional based cross sectional descriptive study design was conducted in 33 formalin fixed Ethiopian cadaveric livers in the Anatomy department of University of Gondar, Bahir Dar University, Addis Ababa University, St. Paulos Medical School and Hawassa University. Results: 45.45% of the liver was normal but 54.55% showed one or more variations. Additional fissures and very small left lobe with deep costal impressions were seen 27.27% and 21.21% cases respectively. Pons hepatis connecting left lobe with quadrate lobe and very deep renal impression with corset constriction were noted in 9.09% cases each. Additional lobes and absence of quadrate lobes were found in 6.06% cases each. Conclusion and Recommendation: Morphological variations on the liver surface were accessory fissure, very small left lobe with deep costal impressions, pons hepatis, shape variation and absence of quadrate lobe. The most common one among the variations was accessory fissure on the visceral and diaphragmatic surface.

  5. Impact of Simulated Knee Injuries on the Patellofemoral and Tibiofemoral Kinematics Investigated with an Electromagnetic Tracking Approach: A Cadaver Study

    Directory of Open Access Journals (Sweden)

    Björn Rath

    2018-01-01

    Full Text Available Purpose. The purpose of this study was to evaluate the approach of using an electromagnetic tracking (EMT system for measuring the effects of stepwise, simulated knee injuries on patellofemoral (PF and tibiofemoral (TF kinematics. Methods. Three cadaver knees were placed in a motion rig. EMT sensors were mounted on the patella, the medial/lateral femoral epicondyles, the tibial condyle, and the tibial tuberosity (TT. After determining the motion of an intact knee, three injuries were simulated and the resulting bony motion was tracked. Results. Starting with the intact knee fully extended (0° flexion and bending it to approximately 20°, the patella shifted slightly in the medial direction. Then, while bending the knee to the flexed position (90° flexion, the patella shifted progressively more laterally. After transecting the anterior cruciate ligament (ACL, the base of the medial menisci (MM at the pars intermedia, and the medial collateral ligament (MCL, individual changes were observed. For example, the medial femoral epicondyle displayed a medial lift-off in all knees. Conclusion. We demonstrated that our EMT approach is an acceptable method to accurately measure PF joint motion. This method could also enable visualization and in-depth analysis of in vivo patellar function in total knee arthroplasty, if it is established for routine clinical use.

  6. Differences in intramuscular vascular connections of human and dog latissimus dorsi muscles.

    Science.gov (United States)

    Yang, D; Morris, S F

    1999-02-01

    Distal ischemia and necrosis of the dog latissimus dorsi muscle flap used in experimental cardiomyoplasty have been reported. However, little information on the intramuscular vascular anatomy of the dog latissimus dorsi is available. It is unclear whether there are any anatomic factors relating to the muscle flap ischemia and necrosis, and whether the dog latissimus dorsi is a suitable experimental model. To study the intramuscular vascular territories in the dog latissimus dorsi muscle, and to compare the intramuscular vasculature of the dog with that of the human, 5 fresh dog cadavers and 7 fresh human cadavers were injected with a mixture of lead oxide, gelatin, and water (200 mL/kg) through the carotid artery. Both the dog and the human latissimus dorsi muscles and neurovascular pedicles were dissected and radiographed. The intramuscular vascular anatomy of the latissimus dorsi muscles was compared. Radiographs demonstrate clearly that the pattern of latissimus dorsi intramuscular anastomoses between branches of the thoracodorsal artery and the perforators of posterior intercostal arteries in the proximal half of the muscle are different between the dog and the human. In the dog muscle, vascular connections between the thoracodorsal artery and the posterior intercostal arteries are formed by reduced-caliber choke arteries, whereas four to six true anastomoses without a change in caliber between them are found in the human muscle. The portion of the latissimus dorsi muscle supplied by the dominant thoracodorsal vascular territory was 25.9% +/- 0.3% in the dog and 23.9% +/- 0.5% in the human. For further comparison, an extended vascular territory in the latissimus dorsi muscle was demonstrated, including both the thoracodorsal territory and the posterior intercostal territories. The area of the extended vascular territory was 52% +/- 0.5% of the total muscle. The dog latissimus dorsi model may not be a perfect predictor of the behavior of the human latissimus

  7. Use of corrosion casting techniques to evaluate coronary collateral vessels and anastomoses in hearts of canine cadavers.

    Science.gov (United States)

    Noestelthaller, Arne; Probst, Alexander; Koenig, Horst E

    2005-10-01

    To study and investigate branching patterns of the canine coronary arteries and collateral circulation by use of corrosion casting techniques. 31 hearts obtained from cadavers of clinically normal dogs of various ages and breeds and of either sex. 3-dimensional reproduction of coronary arteries was achieved by postmortem injection and perfusion with casting materials into the aortic sinus via the ascending aorta. Perfused hearts were macerated and carefully irrigated; the air-dried specimens were examined macroscopically and with a magnifying headset. Collateral arteries and inter- and intra-arterial anastomoses were successfully detected in 8 corrosion cast specimens. In total, 9 coronary collateral arteries and 3 interarterial anastomoses were found. Our finding of coronary collateral arteries in canine hearts is in agreement with recent findings in coronary flow study. On the basis of our results, vasodilation treatment to improve collateral vessel remodeling in dogs with myocardial dysfunction may be warranted.

  8. Sodium magnetic resonance imaging of ankle joint in cadaver specimens, volunteers, and patients after different cartilage repair techniques at 7 T: initial results.

    Science.gov (United States)

    Zbýň, Štefan; Brix, Martin O; Juras, Vladimir; Domayer, Stephan E; Walzer, Sonja M; Mlynarik, Vladimir; Apprich, Sebastian; Buckenmaier, Kai; Windhager, Reinhard; Trattnig, Siegfried

    2015-04-01

    The goal of cartilage repair techniques such as microfracture (MFX) or matrix-associated autologous chondrocyte transplantation (MACT) is to produce repair tissue (RT) with sufficient glycosaminoglycan (GAG) content. Sodium magnetic resonance imaging (MRI) offers a direct and noninvasive evaluation of the GAG content in native cartilage and RT. In the femoral cartilage, this method was able to distinguish between RTs produced by MFX and MACT having different GAG contents. However, it needs to be clarified whether sodium MRI can be useful for evaluating RT in thin ankle cartilage. Thus, the aims of this 7-T study were (1) to validate our sodium MRI protocol in cadaver ankle samples, (2) to evaluate the sodium corrected signal intensities (cSI) in cartilage of volunteers, (3) and to compare sodium values in RT between patients after MFX and MACT treatment. Five human cadaver ankle samples as well as ankles of 9 asymptomatic volunteers, 6 MFX patients and 6 MACT patients were measured in this 7-T study. Sodium values from the ankle samples were compared with histochemically evaluated GAG content. In the volunteers, sodium cSI values were calculated in the cartilages of ankle and subtalar joint. In the patients, sodium cSI in RT and reference cartilage were measured, morphological appearance of RT was evaluated using the magnetic resonance observation of cartilage repair tissue (MOCART) scoring system, and clinical outcome before and after surgery was assessed using the American Orthopaedic Foot and Ankle Society score and Modified Cincinnati Knee Scale. All regions of interest were defined on morphological images and subsequently transferred to the corresponding sodium images. Analysis of variance, t tests, and Pearson correlation coefficients were evaluated. In the patients, significantly lower sodium cSI values were found in RT than in reference cartilage for the MFX (P = 0.007) and MACT patients (P = 0.008). Sodium cSI and MOCART scores in RT did not differ between

  9. A practical femtosecond laser procedure for DLEK endothelial transplantation: cadaver eye histology and topography.

    Science.gov (United States)

    Terry, Mark A; Ousley, Paula J; Will, Brian

    2005-05-01

    The manual dissection technique for deep lamellar endothelial keratoplasty (DLEK) surgery is technically difficult and may not be smooth enough for consistently optimal postoperative vision. We evaluated the feasibility and efficacy of using a femtosecond laser to perform the dissections in the DLEK procedure. The Intralase femtosecond laser (with standard LASIK surgery spot settings) was used to create a 9.4-mm wide, 400-microm deep lamellar pocket dissection and a 5.0-mm wide side cut near-exit incision in 10 "recipient" whole cadaver eyes and in 10 "donor" cadaver corneal-scleral caps mounted onto an artificial anterior chamber. Recipient and donor disks were resected with special scissors, and the donor tissue was transplanted using the small incision (5.0-mm) DLEK technique. Topography of the recipient eyes was measured pre- and postlaser dissection, and the recipient and donor tissues were sent for scanning electron microscopy (SEM) analysis of the smoothness of the dissections. Successful lamellar dissections were obtained in all tissues. The mean recipient topographic corneal curvature postoperatively was 43.3 +/- 1.7 diopters, which was not a significant change from the preoperative curvature of 44.0 +/- 0.8 diopters (P = 0.430). The mean recipient topographic astigmatism postoperatively was 1.7 +/- 0.8 diopters, which was not a significant change from the preoperative recipient astigmatism of 1.6 +/- 0.7 diopters (P = 0.426). Comparison of the histology of the laser-formed stromal dissections by scanning electron microscopy, however, did not appear significantly better than histology after manual DLEK dissections in either the recipient or the donor tissues. A femtosecond laser can create the lamellar dissections for the DLEK procedure, making this procedure easier and faster. As in the manual technique, corneal topography is unchanged by this surgery. More work will need to be done, however, to optimize the laser settings to provide even smoother

  10. Biomechanical evaluation of the impact of various facet joint lesions on the primary stability of anterior plate fixation in cervical dislocation injuries: a cadaver study: Laboratory investigation.

    Science.gov (United States)

    Oberkircher, Ludwig; Born, Sebastian; Struewer, Johannes; Bliemel, Christopher; Buecking, Benjamin; Wack, Christina; Bergmann, Martin; Ruchholtz, Steffen; Krüger, Antonio

    2014-10-01

    Injuries of the subaxial cervical spine including facet joints and posterior ligaments are common. Potential surgical treatments consist of anterior, posterior, or anterior-posterior fixation. Because each approach has its advantages and disadvantages, the best treatment is debated. This biomechanical cadaver study compared the effect of different facet joint injuries on primary stability following anterior plate fixation. Fractures and plate fixation were performed on 15 fresh-frozen intact cervical spines (C3-T1). To simulate a translation-rotation injury in all groups, complete ligament rupture and facet dislocation were simulated by dissecting the entire posterior and anterior ligament complex between C-4 and C-5. In the first group, the facet joints were left intact. In the second group, one facet joint between C-4 and C-5 was removed and the other side was left intact. In the third group, both facet joints between C-4 and C-5 were removed. The authors next performed single-level anterior discectomy and interbody grafting using bone material from the respective thoracic vertebral bodies. An anterior cervical locking plate was used for fixation. Continuous loading was performed using a servohydraulic test bench at 2 N/sec. The mean load failure was measured when the implant failed. In the group in which both facet joints were intact, the mean load failure was 174.6 ± 46.93 N. The mean load failure in the second group where only one facet joint was removed was 127.8 ± 22.83 N. In the group in which both facet joints were removed, the mean load failure was 73.42 ± 32.51 N. There was a significant difference between the first group (both facet joints intact) and the third group (both facet joints removed) (p cadaver study, primary stability of anterior plate fixation for dislocation injuries of the subaxial cervical spine was dependent on the presence of the facet joints. If the bone in one or both facet joints is damaged in the clinical setting, anterior plate

  11. Virtual Reality Anatomy: Is It Comparable with Traditional Methods in the Teaching of Human Forearm Musculoskeletal Anatomy?

    Science.gov (United States)

    Codd, Anthony M.; Choudhury, Bipasha

    2011-01-01

    The use of cadavers to teach anatomy is well established, but limitations with this approach have led to the introduction of alternative teaching methods. One such method is the use of three-dimensional virtual reality computer models. An interactive, three-dimensional computer model of human forearm anterior compartment musculoskeletal anatomy…

  12. The First Survey of Forensically Important Entomofauna Collected from Medicolegal Autopsies in South Korea

    Directory of Open Access Journals (Sweden)

    Sang Eon Shin

    2015-01-01

    Full Text Available Forensic entomology applies insect evidence to legal problems such as the estimation of minimum postmortem interval (mPMI. For this purpose, knowledge of the insect fauna that are attracted to human cadavers in each geographic region is a prerequisite. Despite many studies investigating the insect fauna attracted to meat, there has been no survey of the entomofauna on human cadavers in the East Asian temperate climate zone, particularly in Korea. Therefore, this study reports the entomofauna collected from medicolegal autopsies in northeastern Seoul and its suburbs. Insect samples were collected from 35 medicolegal autopsies in 2010, 2011, and 2013. Molecular and morphological methods were utilized for taxonomic identification. Among 1398 individual samples belonging to 3 orders, 13 families, 18 genera, and 32 species, the dominant family and species were Calliphoridae and Lucilia sericata, respectively. Despite its limited scale, this study provides a snapshot of the general entomofauna that are attracted to human cadavers in this region.

  13. The First Survey of Forensically Important Entomofauna Collected from Medicolegal Autopsies in South Korea

    Science.gov (United States)

    Shin, Sang Eon; Lee, Hyun Ju; Park, Ji Hye; Ko, Kwang Soo; Kim, Yu-Hoon; Kim, Kyung Ryoul

    2015-01-01

    Forensic entomology applies insect evidence to legal problems such as the estimation of minimum postmortem interval (mPMI). For this purpose, knowledge of the insect fauna that are attracted to human cadavers in each geographic region is a prerequisite. Despite many studies investigating the insect fauna attracted to meat, there has been no survey of the entomofauna on human cadavers in the East Asian temperate climate zone, particularly in Korea. Therefore, this study reports the entomofauna collected from medicolegal autopsies in northeastern Seoul and its suburbs. Insect samples were collected from 35 medicolegal autopsies in 2010, 2011, and 2013. Molecular and morphological methods were utilized for taxonomic identification. Among 1398 individual samples belonging to 3 orders, 13 families, 18 genera, and 32 species, the dominant family and species were Calliphoridae and Lucilia sericata, respectively. Despite its limited scale, this study provides a snapshot of the general entomofauna that are attracted to human cadavers in this region. PMID:26185759

  14. Heating produced by therapeutic ultrasound in the presence of a metal plate in the femur of canine cadavers

    Directory of Open Access Journals (Sweden)

    A.O. Andrades

    2014-10-01

    Full Text Available The present study aimed to assess the heat generated by a therapeutic ultrasound (TUS in a metal bone plate and adjacent structures after fixation to the femur of canine cadavers. Ten pairs of hind limbs were used, and they were equally distributed between groups that were subjected to 1- and 3-MHz frequencies, with each frequency testing 1- and 2-W/cm² intensities. The right hind limb was defined as the control group (absence of the metal plate, and the left hind limb was the test group (presence of the metal plate. Therefore, the control groups (CG were denominated CGI, using TUS with 1-MHz frequency and 1-W/cm² intensity; CGII, using 1-MHz frequency and 2-W/cm² intensity; CGIII, using 3-MHz frequency and 1-W/cm² intensity; and CGIV, using 3-MHz frequency and 2-W/cm² intensity. For each control group, its respective test group (TG was denominated TGI, TGII, TGIII and TGIV. The TUS was applied to the lateral aspect of the thigh using the continuous mode and a 3.5-cm² transducer in a 6.25-cm² area for 2 minutes. Sensors were coupled to digital thermometers that measured the temperature in different sites before (t0 and after (t1 of the TUS application. The temperatures in t1 were higher in all tested groups. The intramuscular temperature was significantly higher (P<0.05 in the groups used to test the 3-MHz frequency in the presence of the metal plate. The therapeutic ultrasound in the continuous mode using frequencies of 1 and 3 MHz and intensities of 1 and 2 W/cm2 for 2 minutes caused heating of the metal plate and adjacent structures after fixation to the femur of canine cadavers.

  15. First record of Talaromyces udagawae in soil related to decomposing human remains in Argentina.

    Science.gov (United States)

    Tranchida, María C; Centeno, Néstor D; Stenglein, Sebastián A; Cabello, Marta N

    2016-01-01

    The morphologic features of Talaromyces udagawae Stolk and Samson are here described and illustrated. This teleomorphic Ascomycota fungus was isolated from soil obtained in Buenos Aires province (Argentina) from beneath a human cadaver in an advanced state of decomposition. After washing and serial dilution of the soil along with moist-chamber techniques for fungal cultivation, T. udagawae formed very restricted colonies of bright yellow color on different growth media with 8-ascospored asci. The ascospores were ellipsoidal and ornamented. The anamorphic state was not observed. Molecular-genetic techniques identified the species. The present record is the first of the species in Argentina, pointing it as a tool to identify soils where cadaver decomposition occurs. Copyright © 2015 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Virtual reality haptic human dissection.

    Science.gov (United States)

    Needham, Caroline; Wilkinson, Caroline; Soames, Roger

    2011-01-01

    This project aims to create a three-dimensional digital model of the human hand and wrist which can be virtually 'dissected' through a haptic interface. Tissue properties will be added to the various anatomical structures to replicate a realistic look and feel. The project will explore the role of the medical artist and investigate the cross-discipline collaborations required in the field of virtual anatomy. The software will be used to train anatomy students in dissection skills before experience on a real cadaver. The effectiveness of the software will be evaluated and assessed both quantitatively as well as qualitatively.

  17. Correlations between radiographic, magnetic resonance and histological examinations on the degeneration of human lumbar intervertebral discs

    Directory of Open Access Journals (Sweden)

    Delio Eulalio Martins

    Full Text Available CONTEXT AND OBJECTIVE: There is controversy regarding which imaging method is best for identifying early degenerative alterations in intervertebral discs. No correlations between such methods and histological finds are presented in the literature. The aim of this study was to correlate the thickness of intervertebral discs measured on simple radiographs with the degree of degeneration seen on magnetic resonance images and the histological findings relating to nerve ends inside the discs. DESIGN AND SETTING: Cross-sectional correlation study on the lumbar spines of human cadavers, at Universidade Federal de São Paulo (Unifesp, São Paulo, Brazil. METHODS: Ten lumbar spinal columns were extracted from human cadavers and subjected to magnetic resonance imaging and simple radiography. They were classified according to the degree of disc degeneration seen on magnetic resonance, and the thickness of the discs was measured on radiographs. The intervertebral discs were then extracted, embedded in paraffin and analyzed immunohistochemically with protein S100, and the nerve fibers were counted and classified. RESULTS: No correlation was observed between the thickness of the intervertebral discs and the degree of degeneration seen on magnetic resonance images. Only the uppermost lumbar discs (L1/L2 and L2/L3 presented a correlation between their thickness and type I and IV nerve endings. CONCLUSION: Reduced disc thickness is unrelated to increased presence of nerve ends in intervertebral discs, or to the degree of disc degeneration.

  18. Clinical evaluation of lumbar CT assisted discography in comparison with human cadaver

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shigehiko

    1988-04-01

    In order to estimate the clinical value of lumbar CT assisted discography (CTD), results obtained by this method were compared with histological findings of the cross section of the spine in fresh human cadavera. Based on these findings, preoperative CTD of lumbar disc herniation was investigated. In the discs of human cadavera, the contrast medium mainly invaded the fissures of nucleus pulposus and the ruptures of annulus fibrosus and then diffused to the surrounding tissues. These ruptures were classified into two categories: radial and circumferential. This indentification was possible only in CTD and was obscure in the usual discogram. Not all the ruptures could be dyed in a severe degenerative disc, and a rupture which was not communicated with nucleus pulposus was not dyed in a mild degenerative disc. In the preoperative CTD of lumbar disc herniation, the posterior radial ruptures representing the route of herniated nuclei were characteristic and the circumferential ruptures were found complicated.

  19. Transfer of extensor digiti minimi and extensor carpi ulnaris nerve branches to the intrinsic motor nerve branches: A histological study on cadaver.

    Science.gov (United States)

    Namazi, H; Haji Vandi, S

    2017-06-01

    In cases of high ulnar and median nerve palsy, result of nerve repair in term of intrinsic muscle recovery is unsatisfactory. Distal nerve transfer can alleviate the regeneration time and improve the results. Transfer of the extensor digiti minimi (EDM) and extensor carpi ulnaris (ECU) nerve branches to the deep branch of ulnar nerve (DBUN)/recurrent branch of median nerve (RMN) at wrist had been used to restore intrinsic hand function but, incomplete recovery occurred. The axon count at the donor nerve has a strong influence on the final results. This cadaveric study aims to analyses the histology of this nerve transfer to evaluate whether these donor nerves are suitable for this transfer or another donor nerve may be considered. Ten cadaveric upper limbs dissected to identify the location of the EDM, ECU, RMN and DBUN. Surface area, fascicle count, and axon number was determined by histological methods. The mean of axon number in the EDM, ECU, RMN and DBUN branches was 5931, 7355, 30960 and 35426, respectively. In this study, the number of axons in the EDM and ECU branches was 37% (13281/35426) of that in the DBUN. Also, the number of axons in the EDM and ECU branches was 42% (13281/30960) of that in the RMN. The axon count data showed an unfavorable match between the EDM, ECU and DBUN/RMN. Therefore, it is suggested that another donor nerve with higher axon number to be considered. Cadaver study (histological study). Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Medical Student Dissection of CadaversImproves Performance on Practical Exams, but not Dissection-Relevant Questions in the NBME Gross Anatomy and Embryology Final Exam

    Directory of Open Access Journals (Sweden)

    Leslie Sargent Jones

    2001-03-01

    Full Text Available We have examined whether cadaver dissection by first year medical students (MIs affected their performance in two test measures: the NBME Gross Anatomy and Embryology Subject Exam (dissection-relevant questions only, and practical exams given at the end of each major section within the course. The dissections for the entire course were divided into 18 regional dissection units and each student was assigned to dissect one third of the regional units; the other two-thirds of the material was learned from the partner-prosected cadavers. Performance for each student on the exams was then assessed as a function of the regions those students actually dissected. While the results indicated a small performance advantage for MIs answering questions on material they had dissected on the NBME Subject Exam questions relevant to dissection (78-88% of total exam, the results were not statistically significant. However, a similar, small performance advantage on the course practical exams was highly significant.

  1. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver

    Science.gov (United States)

    Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-07-01

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.

  2. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver

    International Nuclear Information System (INIS)

    Yeom, Yeon Soo; Kim, Chan Hyeong; Han, Min Cheol; Jeong, Jong Hwi; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-01-01

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms. (paper)

  3. HDRK-Woman: whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver.

    Science.gov (United States)

    Yeom, Yeon Soo; Jeong, Jong Hwi; Kim, Chan Hyeong; Han, Min Cheol; Ham, Bo Kyoung; Cho, Kun Woo; Hwang, Sung Bae

    2014-07-21

    In a previous study, we constructed a male reference Korean phantom; HDRK-Man (High-Definition Reference Korean-Man), to represent Korean adult males for radiation protection purposes. In the present study, a female phantom; HDRK-Woman (High-Definition Reference Korean-Woman), was constructed to represent Korean adult females. High-resolution color photographic images obtained by serial sectioning of a 26 year-old Korean adult female cadaver were utilized. The body height and weight, the skeletal mass, and the dimensions of the individual organs and tissues were adjusted to the reference Korean data. The phantom was then compared with the International Commission on Radiological Protection (ICRP) female reference phantom in terms of calculated organ doses and organ-depth distributions. Additionally, the effective doses were calculated using both the HDRK-Man and HDRK-Woman phantoms, and the values were compared with those of the ICRP reference phantoms.

  4. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Science.gov (United States)

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Development and application of the Chinese adult female computational phantom Rad-HUMAN

    International Nuclear Information System (INIS)

    Wu, Yican; Cheng, Mengyun; Wang, Wen; Fan, Yanchang; Zhao, Kai; He, Tao; Pei, Xi; Shang, Leiming; Chen, Chaobin; Long, Pengcheng; Cao, Ruifen; Wang, Guozhong; Zhou, Shaoheng; Yu, Shengpeng; Hu, Liqin; Zeng, Q.

    2013-01-01

    Rad-HUMAN is a whole-body numerical phantom of a Chinese adult woman which contains 46 organs and tissues and was created by MCAM6 software using the color photographs of the Chinese Visible Human dataset. This dataset was obtained from a 22-year old Chinese female cadaver judged to represent normal human anatomy as much as possible. The density and elemental composition recommended in the ICRP Publication 89 and in the ICRU report 44 were assigned to the organ and tissue in Rad-HUMAN for radiation protection purpose. The last step was to implement the anatomical data into a Monte Carlo code. Rad-HUMAN contains more than 28.8 billion tiny volume units, which produces an accurately whole-body numerical phantom of a Chinese adult female

  6. In situ measurement and modeling of biomechanical response of human cadaveric soft tissues for physics-based surgical simulation.

    Science.gov (United States)

    Lim, Yi-Je; Deo, Dhanannjay; Singh, Tejinder P; Jones, Daniel B; De, Suvranu

    2009-06-01

    Development of a laparoscopic surgery simulator that delivers high-fidelity visual and haptic (force) feedback, based on the physical models of soft tissues, requires the use of empirical data on the mechanical behavior of intra-abdominal organs under the action of external forces. As experiments on live human patients present significant risks, the use of cadavers presents an alternative. We present techniques of measuring and modeling the mechanical response of human cadaveric tissue for the purpose of developing a realistic model. The major contribution of this paper is the development of physics-based models of soft tissues that range from linear elastic models to nonlinear viscoelastic models which are efficient for application within the framework of a real-time surgery simulator. To investigate the in situ mechanical, static, and dynamic properties of intra-abdominal organs, we have developed a high-precision instrument by retrofitting a robotic device from Sensable Technologies (position resolution of 0.03 mm) with a six-axis Nano 17 force-torque sensor from ATI Industrial Automation (force resolution of 1/1,280 N along each axis), and used it to apply precise displacement stimuli and record the force response of liver and stomach of ten fresh human cadavers. The mean elastic modulus of liver and stomach is estimated as 5.9359 kPa and 1.9119 kPa, respectively over the range of indentation depths tested. We have also obtained the parameters of a quasilinear viscoelastic (QLV) model to represent the nonlinear viscoelastic behavior of the cadaver stomach and liver over a range of indentation depths and speeds. The models are found to have an excellent goodness of fit (with R (2) > 0.99). The data and models presented in this paper together with additional ones based on the principles presented in this paper would result in realistic physics-based surgical simulators.

  7. Use of the iTClamp versus standard suturing techniques for securing chest tubes: A randomized controlled cadaver study

    Directory of Open Access Journals (Sweden)

    Jessica Mckee

    2018-03-01

    Full Text Available Objectives: Tube thoracostomy (TT is a common yet potentially life-saving trauma procedure. After successful placement however, securing a TT through suturing is a skillset that requires practice, risking that the TT may become dislodged during prehospital transport. The purpose of this study was to examine if the iTClamp was a simpler technique with equivalent effectiveness for securing TTs. Materials and methods: In a cadaver model, a 1.5 inch incision was utilized along the upper border of the rib below the 5th intercostal space at the anterior axillary line. TTs (sizes 28Fr, 32Fr, 36Fr and 40Fr were inserted and secured with both suturing and iTClamp techniques according to the preset randomization. TT were then functionally tested for positive and negative pressure as well as the force required to remove the TT (pull test-up to 5 lbs. Time to secure the TT was also recorded. Results: When sutured is placed by a trained surgeon, the sutures and iTClamp were functionally equivalent for holding a positive and negative pressure. Mean pull force for both sutures and iTClamp exceeded the 5 lb threshold; there was no significant difference between the groups. Securing the TT with the iTClamp was significantly faster (p < 0.0001 with the iTClamp having a mean application time of 37.0 ± 22.8 s and using a suture had a man application time of 96.3 ± 29.0 s. Conclusion: The iTClamp was effective in securing TTs. The main benefit to the iTClamp is that minimal skill is required to adequately secure a TT to ensure that it does not become dislodged during transport to a trauma center. Keywords: Chest tube, Tube thoracostomy, Securing chest tubes

  8. Acinar autolysis and mucous extravasation in human sublingual glands: a microscopic postmortem study.

    Science.gov (United States)

    Azevedo-Alanis, Luciana Reis; Tolentino, Elen de Souza; de Assis, Gerson Francisco; Cestari, Tânia Mary; Lara, Vanessa Soares; Damante, José Humberto

    2015-10-01

    Although some morphological investigations on aged human sublingual glands (HSG) found eventual phenomena identified as autolysis and mucous extravasation, the exact meaning of these findings has not been elucidated. The aim of this work is to investigate whether acinar autolysis and mucous extravasation are related to the aging process in human sublingual glands. We also speculate if autolytic changes may assist forensic pathologists in determining time of death. 186 cadavers' glands were allocated to age groups: I (0-30 years); II (31-60), and III (61-90). Time and mode of death were also recorded. Acinar autolysis and mucous extravasation were classified as present or absent. Ultrastructural analysis was performed using transmission electron microscopy (TEM). Data were compared using Mann-Whitney U, Spearman's correlation coefficient, Kruskal-Wallis, and Dunn tests (pautolysis (r=0.38; p=0.0001). However, there was no correlation between autolysis and time of death. No differences were observed between genders. TEM showed mucous and serous cells presenting nuclear and membrane alterations and mucous cells were more susceptible to autolysis. Acinar autolysis occurred in all age groups and increased with age while mucous extravasation was rarely found. Both findings are independent. Autolysis degrees in HSG could not be used to determine time of death.

  9. Differential Gene Expression in Explanted Human Retinal Pigment Epithelial Cells 24-Hours Post-Exposure to 532 nm, 3.0 ns Pulsed Laser Light and 1064 nm, 170 ps Pulsed Laser Light 12-Hours Post-Exposure: Results Compendium

    National Research Council Canada - National Science Library

    Obringer, John

    2004-01-01

    .... We assessed the sublethal insult to human retinal pigment epithelial cells using a cadaver organ donor explant system for genes differentially expressed 12 and 24 hours post- exposure using gene...

  10. Pedicle distraction increases intervertebral and spinal canal area in a cadaver and bone model.

    Science.gov (United States)

    Hughes, Matthew; Papadakos, Nikolaos; Bishop, Tim; Bernard, Jason

    2018-01-01

    Lumbar spinal stenosis is degenerative narrowing of the spinal canal and/or intervertebral foramen causing compression of the spinal cord and nerve roots. Traditional decompression techniques can often cause significant trauma and vertebral instability. This paper evaluates a method of increasing pedicle length to decompress the spinal and intervertebral foramen, which could be done minimally invasive. Three Sawbone (Sawbones Europe, Sweden) and 1 cadaveric lumbar spine underwent bilateral pedicle distraction at L4. A pedicle channel was drilled between the superior articular process and transverse process into the vertebral body. The pedicles underwent osteotomy at the midpoint. Screws were inserted bilaterally and fixated distraction of 0 mm, 2 mm, 4 mm and 6 mm. CT images were taken at each level of distraction. Foramen area was measured in the sagittal plane at L3/4. Spinal canal area was measured at L4 in the axial images. The cadaver was used to evaluate safety of osteotomy and soft tissue interactions preventing distraction. Statistical analysis was by student paired t-test and Pearson rank test. Increasing distraction led to greater Spinal canal area. From 4.27 cm 2 to 5.72 cm 2 (p = 0.002) with 6 mm distraction. A Maximal increase of 34.1%. Vertebral foramen area also increased with increasing pedicle distraction. From 2.43 cm 2 to 3.22 cm 2 (p = 0.022) with 6 mm distraction. A maximal increase of 32.3%. The cadaver spinal canal increased in area by 21.7%. The vertebral foramen increased in area by 36.2% (left) and 22.6% (right). For each increase in pedicle distraction the area of the spinal and vertebral foramen increases. Pedicle distraction could potentially be used to alleviate spinal stenosis and root impingement. A potential osteotomy plane could be at the midpoint of the pedicle with minimal risk to nerve roots and soft tissue restrictions to prevent distraction. © The Authors, published by EDP Sciences, 2018.

  11. Balloon osteoplasty--a new technique for reduction and stabilisation of impression fractures in the tibial plateau: a cadaver study and first clinical application.

    Science.gov (United States)

    Ahrens, Philipp; Sandmann, Gunther; Bauer, Jan; König, Benjamin; Martetschläger, Frank; Müller, Dirk; Siebenlist, Sebastian; Kirchhoff, Chlodwig; Neumaier, Markus; Biberthaler, Peter; Stöckle, Ulrich; Freude, Thomas

    2012-09-01

    Fractures of the tibial plateau are among the most severe injuries of the knee joint and lead to advanced gonarthrosis if the reduction does not restore perfect joint congruency. Many different reduction techniques focusing on open surgical procedures have been described in the past. In this context we would like to introduce a novel technique which was first tested in a cadaver setup and has undergone its successful first clinical application. Since kyphoplasty demonstrated effective ways of anatomical correction in spine fractures, we adapted the inflatable instruments and used the balloon technique to reduce depressed fragments of the tibial plateau. The technique enabled us to restore a congruent cartilage surface and bone reduction. In this technique we see a useful new method to reduce depressed fractures of the tibial plateau with the advantages of low collateral damage as it is known from minimally invasive procedures.

  12. Radiological assessment of the inferior alveolar artery course in human corpse mandibles

    Energy Technology Data Exchange (ETDEWEB)

    Bertl, Kristina [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Malmoe University, Department of Periodontology, Faculty of Odontology, Malmoe (Sweden); Hirtler, Lena [Medical University of Vienna, Center for Anatomy and Cell Biology, Department of Systematic Anatomy, Vienna (Austria); Dobsak, Toni [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Medical University of Vienna, Karl Donath Laboratory for Hard Tissue and Biomaterial Research, Division of Oral Surgery, Vienna (Austria); Austrian Cluster for Tissue Regeneration, Vienna (Austria); Heimel, Patrick [Medical University of Vienna, Karl Donath Laboratory for Hard Tissue and Biomaterial Research, Division of Oral Surgery, Vienna (Austria); Austrian Cluster for Tissue Regeneration, Vienna (Austria); Ludwig Boltzmann Institute for Clinical and Experimental Traumatology, Vienna (Austria); Gahleitner, Andre [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Medical University of Vienna, Department of Diagnostic Radiology, Division of Osteoradiology, General Hospital, Vienna (Austria); Ulm, Christian [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Plenk, Hanns [Medical University of Vienna, Bone and Biomaterials Research, Institute for Histology and Embryology, Vienna (Austria)

    2015-04-01

    CT assessment of the entire course of the inferior alveolar artery (IAA) within the mandibular canal. After contrast medium injection (180 or 400 mg/ml iodine concentration) into the external carotid arteries of 15 fresh human cadaver heads, the main IAA's position in the canal (cranial, buccal, lingual or caudal) was assessed in dental CT images of partially edentulous mandibles. The course of the main IAA could be followed at both iodine concentrations. The higher concentration gave the expected better contrast, without creating artefacts, and improved visibility of smaller arteries, such as anastomotic sections, dental branches and the incisive branch. The main IAA changed its position in the canal more often than so far known (mean 4.3 times, SD 1.24, range 2-7), but with a similar bilateral course. A cranial position was most often detected (42 %), followed by lingual (36 %), caudal (16 %) and buccal (6 %). With this non-invasive radiologic method, the entire course of the main IAA in the mandibular canal could be followed simultaneously with other bone structures on both sides of human cadaver mandibles. This methodology allows one to amend existing anatomical and histological data, which are important for surgical interventions near the mandibular canal. (orig.)

  13. Radiological assessment of the inferior alveolar artery course in human corpse mandibles

    International Nuclear Information System (INIS)

    Bertl, Kristina; Hirtler, Lena; Dobsak, Toni; Heimel, Patrick; Gahleitner, Andre; Ulm, Christian; Plenk, Hanns

    2015-01-01

    CT assessment of the entire course of the inferior alveolar artery (IAA) within the mandibular canal. After contrast medium injection (180 or 400 mg/ml iodine concentration) into the external carotid arteries of 15 fresh human cadaver heads, the main IAA's position in the canal (cranial, buccal, lingual or caudal) was assessed in dental CT images of partially edentulous mandibles. The course of the main IAA could be followed at both iodine concentrations. The higher concentration gave the expected better contrast, without creating artefacts, and improved visibility of smaller arteries, such as anastomotic sections, dental branches and the incisive branch. The main IAA changed its position in the canal more often than so far known (mean 4.3 times, SD 1.24, range 2-7), but with a similar bilateral course. A cranial position was most often detected (42 %), followed by lingual (36 %), caudal (16 %) and buccal (6 %). With this non-invasive radiologic method, the entire course of the main IAA in the mandibular canal could be followed simultaneously with other bone structures on both sides of human cadaver mandibles. This methodology allows one to amend existing anatomical and histological data, which are important for surgical interventions near the mandibular canal. (orig.)

  14. The persistence of human DNA in soil following surface decomposition.

    Science.gov (United States)

    Emmons, Alexandra L; DeBruyn, Jennifer M; Mundorff, Amy Z; Cobaugh, Kelly L; Cabana, Graciela S

    2017-09-01

    Though recent decades have seen a marked increase in research concerning the impact of human decomposition on the grave soil environment, the fate of human DNA in grave soil has been relatively understudied. With the purpose of supplementing the growing body of literature in forensic soil taphonomy, this study assessed the relative persistence of human DNA in soil over the course of decomposition. Endpoint PCR was used to assess the presence or absence of human nuclear and mitochondrial DNA, while qPCR was used to evaluate the quantity of human DNA recovered from the soil beneath four cadavers at the University of Tennessee's Anthropology Research Facility (ARF). Human nuclear DNA from the soil was largely unrecoverable, while human mitochondrial DNA was detectable in the soil throughout all decomposition stages. Mitochondrial DNA copy abundances were not significantly different between decomposition stages and were not significantly correlated to soil edaphic parameters tested. There was, however, a significant positive correlation between mitochondrial DNA copy abundances and the human associated bacteria, Bacteroides, as estimated by 16S rRNA gene abundances. These results show that human mitochondrial DNA can persist in grave soil and be consistently detected throughout decomposition. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  15. Radiographic Detectability of Retained Neuropatties in a Cadaver Model.

    Science.gov (United States)

    Luo, Wangjian Thomas; Almack, Robert; Mawson, John B; Cochrane, David Douglas

    2015-08-01

    Counts are the commonest method used to ensure that all sponges and neuropatties are removed from a surgical site before closure. When the count is not reconciled, plain radiographs of the operative site are taken to determine whether the missing patty has been left in the wound. The purpose of this study was to describe the detectability of commonly used neuropatties in the clinical setting using digital technologies. Neuropatties were implanted into the anterior and posterior cranial fossae and the thoracolumbar extradural space of a mature male cadaver. Four neuropatty sizes were used: 3 × 1 in, 2 × ½ in, ½ × ½ in, and ¼ × ¼ in. Neuropatties, with size and location chosen at random, were placed in the surgical sites and anteroposterior/posterior-anterior and lateral radiographs were taken using standard portable digital radiographic equipment. Six clinicians reviewed the digital images for the presence or absence of neuropatties. The readers were not aware of the number and size of the patties that were included in each image. The detectability of neuropatties is dependent on the size of the neuropatty's radiopaque marker and the operative site. Neuropatties measuring 2 × ½ in and 3 × 1 in were detected reliably regardless of the operative site. ¼ × ¼ in neuropatties were poorly detected by neurosurgeons and radiologists in all three operative sites. Readers of various experience and background were similar in their ability to detect neuropatties under these conditions. Under simulated operating room conditions and using currently available neuropatties and plain radiograph imaging technology, small ¼-in and ½-in neuropatties are poorly visible/detectable on digital images. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. The Search for a Volatile Human Specific Marker in the Decomposition Process.

    Directory of Open Access Journals (Sweden)

    E Rosier

    Full Text Available In this study, a validated method using a thermal desorber combined with a gas chromatograph coupled to mass spectrometry was used to identify the volatile organic compounds released during decomposition of 6 human and 26 animal remains in a laboratory environment during a period of 6 months. 452 compounds were identified. Among them a human specific marker was sought using principle component analysis. We found a combination of 8 compounds (ethyl propionate, propyl propionate, propyl butyrate, ethyl pentanoate, pyridine, diethyl disulfide, methyl(methylthioethyl disulfide and 3-methylthio-1-propanol that led to the distinction of human and pig remains from other animal remains. Furthermore, it was possible to separate the pig remains from human remains based on 5 esters (3-methylbutyl pentanoate, 3-methylbutyl 3-methylbutyrate, 3-methylbutyl 2-methylbutyrate, butyl pentanoate and propyl hexanoate. Further research in the field with full bodies has to corroborate these results and search for one or more human specific markers. These markers would allow a more efficiently training of cadaver dogs or portable detection devices could be developed.

  17. The Search for a Volatile Human Specific Marker in the Decomposition Process

    Science.gov (United States)

    Rosier, E.; Loix, S.; Develter, W.; Van de Voorde, W.; Tytgat, J.; Cuypers, E.

    2015-01-01

    In this study, a validated method using a thermal desorber combined with a gas chromatograph coupled to mass spectrometry was used to identify the volatile organic compounds released during decomposition of 6 human and 26 animal remains in a laboratory environment during a period of 6 months. 452 compounds were identified. Among them a human specific marker was sought using principle component analysis. We found a combination of 8 compounds (ethyl propionate, propyl propionate, propyl butyrate, ethyl pentanoate, pyridine, diethyl disulfide, methyl(methylthio)ethyl disulfide and 3-methylthio-1-propanol) that led to the distinction of human and pig remains from other animal remains. Furthermore, it was possible to separate the pig remains from human remains based on 5 esters (3-methylbutyl pentanoate, 3-methylbutyl 3-methylbutyrate, 3-methylbutyl 2-methylbutyrate, butyl pentanoate and propyl hexanoate). Further research in the field with full bodies has to corroborate these results and search for one or more human specific markers. These markers would allow a more efficiently training of cadaver dogs or portable detection devices could be developed. PMID:26375029

  18. Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.

    Science.gov (United States)

    Chang, David F; Mamalis, Nick; Werner, Liliana

    2016-02-01

    To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Human cadaver eyes and New Zealand white rabbits. Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy discharge to produce a perfectly round anterior capsulotomy instantaneously and simultaneously along all 360°. Capsulotomies are performed using a disposable handpiece with a soft collapsible tip and circular nitinol cutting element. Miyake-Apple imaging and scanning electron microscopy (SEM) of PPC were conducted in human cadaver eyes. Surgical, postoperative slit-lamp, and histopathologic assessments of PPC were performed in 20 live rabbits and were compared with manual continuous curvilinear capsulorrhexis (CCC) in the fellow eye. Anterior chamber (AC) thermocouple temperature measurements were evaluated in a subset of rabbit eyes. Capsulotomy edge circularity, SEM morphologic features and zonular movement with PPC in human cadaver eyes. Anterior chamber temperature during PPC and grading of ocular inflammation, corneal endothelial damage, anterior capsular opacification (ACO), and posterior capsular opacification (PCO). Miyake-Apple imaging showed minimal zonular stress, and thermocouple measurements demonstrated negligible AC temperature changes during PPC. Precision pulse capsulotomy produced round, complete capsulotomies in all 20 rabbit eyes, leading to successful in-the-bag intraocular lens (IOL) implantation. Slit-lamp examinations at 3 days and 1, 2, and 4 weeks after surgery showed no significant differences between PPC and CCC in corneal edema, AC inflammatory reaction, capsular fibrosis, ACO, and PCO. Postmortem studies showed no difference in the corneal endothelium between PPC and CCC eyes. All IOLs were well centered in PPC eyes, and histopathologic analysis showed no greater inflammatory

  19. A new beating-heart off-pump coronary artery bypass grafting training model

    NARCIS (Netherlands)

    Bouma, Wobbe; Kuijpers, Michiel; Bijleveld, Aanke; De Maat, Gijs E.; Koene, Bart M.; Erasmus, Michiel E.; Natour, Ehsan; Mariani, Massimo A.

    OBJECTIVES: Training models are essential in mastering the skills required for off-pump coronary artery bypass grafting (OPCAB). We describe a new, high-fidelity, effective and reproducible beating-heart OPCAB training model in human cadavers. METHODS: Human cadavers were embalmed according to the

  20. Influence of meniscus on cartilage and subchondral bone features of knees from older individuals: A cadaver study.

    Science.gov (United States)

    Touraine, Sébastien; Bouhadoun, Hamid; Engelke, Klaus; Laredo, Jean Denis; Chappard, Christine

    2017-01-01

    Cartilage and subchondral bone form a functional unit. Here, we aimed to examine the effect of meniscus coverage on the characteristics of this unit in knees of older individuals. We assessed the hyaline cartilage, subchondral cortical plate (SCP), and subchondral trabecular bone in areas covered or uncovered by the meniscus from normal cadaver knees (without degeneration). Bone cores harvested from the medial tibial plateau at locations uncovered (central), partially covered (posterior), and completely covered (peripheral) by the meniscus were imaged by micro-CT. The following were measured on images: cartilage volume (Cart.Vol, mm3) and thickness (Cart.Th, mm); SCP thickness (SCP.Th, μm) and porosity (SCP.Por, %); bone volume to total volume fraction (BV/TV, %); trabecular thickness (Tb.Th, μm), spacing (Tb.Sp, μm), and number (Tb.N, 1/mm); structure model index (SMI); trabecular pattern factor (Tb.Pf); and degree of anisotropy (DA). Among the 28 specimens studied (18 females) from individuals with mean age 82.8±10.2 years, cartilage and SCP were thicker at the central site uncovered by the meniscus than the posterior and peripheral sites, and Cart.Vol was greater. SCP.Por was highest in posterior samples. In the upper 1-5 mm of subchondral bone, central samples were characterized by higher values for BV/TV, Tb.N, Tb.Th, and connectivity (Tb.Pf), a more plate-like trabecular structure and lower anisotropy than with other samples. Deeper down, at 6-10 mm, the differences were slightly higher for Tb.Th centrally, DA peripherally and SMI posteriorly. The coverage or not by meniscus in the knee of older individuals is significantly associated with Cart.Th, SCP.Th, SCP.Por and trabecular microarchitectural parameters in the most superficial 5 mm and to a lesser extent the deepest area of subchondral trabecular bone. These results suggest an effect of differences in local loading conditions. In subchondral bone uncovered by the meniscus, the trabecular architecture

  1. Influence of meniscus on cartilage and subchondral bone features of knees from older individuals: A cadaver study.

    Directory of Open Access Journals (Sweden)

    Sébastien Touraine

    Full Text Available Cartilage and subchondral bone form a functional unit. Here, we aimed to examine the effect of meniscus coverage on the characteristics of this unit in knees of older individuals.We assessed the hyaline cartilage, subchondral cortical plate (SCP, and subchondral trabecular bone in areas covered or uncovered by the meniscus from normal cadaver knees (without degeneration. Bone cores harvested from the medial tibial plateau at locations uncovered (central, partially covered (posterior, and completely covered (peripheral by the meniscus were imaged by micro-CT. The following were measured on images: cartilage volume (Cart.Vol, mm3 and thickness (Cart.Th, mm; SCP thickness (SCP.Th, μm and porosity (SCP.Por, %; bone volume to total volume fraction (BV/TV, %; trabecular thickness (Tb.Th, μm, spacing (Tb.Sp, μm, and number (Tb.N, 1/mm; structure model index (SMI; trabecular pattern factor (Tb.Pf; and degree of anisotropy (DA.Among the 28 specimens studied (18 females from individuals with mean age 82.8±10.2 years, cartilage and SCP were thicker at the central site uncovered by the meniscus than the posterior and peripheral sites, and Cart.Vol was greater. SCP.Por was highest in posterior samples. In the upper 1-5 mm of subchondral bone, central samples were characterized by higher values for BV/TV, Tb.N, Tb.Th, and connectivity (Tb.Pf, a more plate-like trabecular structure and lower anisotropy than with other samples. Deeper down, at 6-10 mm, the differences were slightly higher for Tb.Th centrally, DA peripherally and SMI posteriorly.The coverage or not by meniscus in the knee of older individuals is significantly associated with Cart.Th, SCP.Th, SCP.Por and trabecular microarchitectural parameters in the most superficial 5 mm and to a lesser extent the deepest area of subchondral trabecular bone. These results suggest an effect of differences in local loading conditions. In subchondral bone uncovered by the meniscus, the trabecular architecture

  2. Anatomical variations of the iliolumbar vein with application to the anterior retroperitoneal approach to the lumbar spine: a cadaver study.

    Science.gov (United States)

    Unruh, Kenneth P; Camp, Christopher L; Zietlow, Scott P; Huddleston, Paul M

    2008-10-01

    Objectives of this study include identification of lumbosacral venous variations, designation of a critical area of dissection for surgical exposure, and comparison between both male/female and right/left-sided anatomy. Attempts were made to provide anatomic nomenclature that accurately describes these structures. Thirty-eight iliolumbar venous systems in 20 cadavers (11 females/9 males) were dissected. Each system was identified as one of three patterns of variation: common venous trunk (combining ascending lumbar and iliolumbar venous systems) with distal veins, common venous trunk without distal veins, and venous systems without a common venous trunk. Dimensions including distances to the inferior vena cava (IVC) confluence, the obturator nerve, and the lumbosacral trunk, and venous stem length were obtained to aid surgical dissection. Differences between males and females and those between right and left sides were compared. Anterior lumbosacral venous variations could be organized into three groups. A Type 1 venous system (common venous trunk with distal veins) was most common (53% of systems). The anatomical name "lateral lumbosacral veins" adequately describes the anatomical location of these veins and does not assume a direction of venous flow or the lack of individual distal veins. A critical area bordered by the obturator nerve anteriorly, the psoas muscle laterally, the spinal column medially, and sacrum posteriorly within 8.2 cm of the IVC confluence should be defined to adequately dissect the lateral lumbosacral veins. Differences in male and female lateral lumbosacral venous anatomy do not alter surgeon's approach to the anterior lumbar spine. (c) 2008 Wiley-Liss, Inc.

  3. In-vitro percutaneous absorption of losartan potassium in human skin and prediction of human skin permeability

    Directory of Open Access Journals (Sweden)

    Petkar K.C.

    2007-05-01

    Full Text Available This study describes the feasibility of transdermal controlled administration of Losartan potassium (LP across human cadaver skin. Study also defines the influence of capsaicin, sex and site of application on permeation characteristics and determined an appropriate animal model for human skin permeability. The permeation of LP of various formulations was studied using Keshary-Chein diffusion cell. Optimized controlled formulation (without capsaicin released 42.17% (±1.85 of LP in 12 hr whereas treatment formulation (with capsaicin 0.028 % w/v released 48.94% (±1.71 of LP with significant difference on null hypothesis. Influence of sex showed statistically significant difference for permeation of LP through male and female rats, as well as male and female mice across both the abdominal and dorsal sides of the skin (p<0.05. Similarly statistically significant differences were noted for permeation of LP across male and female mice abdomen-dorsal, but not for male rat abdomen-dorsal and female rat abdomen-dorsal. Furthermore, in-vitro permeation of LP across human skin was compared with the permeation across rat and mice skins. Male rat and male mice dorsal skin was found to have closer permeability characteristics to human than other skin membranes, but the Factor of Difference values were < 3 for all membranes which were used suggesting the membranes are good models for human skin permeability. In conclusion simple transdermal adhesive patches formulations incorporating high molecular weight of LP can deliver a dose in-vivo and proposed model skin membranes can be utilized for future pharmacokineic and toxicokinetic studies as well as metabolism studies of LP

  4. The Vesalius Project: Interactive Computers in Anatomical Instruction.

    Science.gov (United States)

    McCracken, Thomas O.; Spurgeon, Thomas L.

    1991-01-01

    Described is a high-resolution, interactive 3-D atlas of human/animal anatomy that students will use to learn the structure of the body and to understand their own bodies in health and disease. This system can be used to reinforce cadaver study or to serve as a substitute for institutions where it is not practical to use cadavers. (KR)

  5. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model.

    Science.gov (United States)

    Somberg, Andrew Max; Whiteside, William K; Nilssen, Erik; Murawski, Daniel; Liu, Wei

    2016-03-01

    Many types of screws, plates, and strut grafts have been utilized for ankle arthrodesis. Biomechanical testing has shown that these constructs can have variable stiffness. More recently, headless compression screws have emerged as an evolving method of achieving compression in various applications but there is limited literature regarding ankle arthrodesis. The aim of this study was to determine the biomechanical stability provided by a second generation fully threaded headless compression screw compared to a standard headed, partially threaded cancellous screw in a cadaveric ankle arthrodesis model. Twenty fresh frozen human cadaver specimens were subjected to simulated ankle arthrodesis with either three standard cancellous-bone screws (InFix 7.3mm) or with three headless compression screws (Acumed Acutrak 2 7.5mm). The specimens were subjected to cyclic loading and unloading at a rate of 1Hz, compression of 525 Newtons (N) and distraction of 20N for a total of 500 cycles using an electromechanical load frame (Instron). The amount of maximum distraction was recorded as well as the amount of motion that occurred through 1, 10, 50, 100, and 500 cycles. No significant difference (p=0.412) was seen in the amount of distraction that occurred across the fusion site for either screw. The average maximum distraction after 500 cycles was 201.9μm for the Acutrak 2 screw and 235.4μm for the InFix screw. No difference was seen throughout each cycle over time for the Acutrak 2 screw (p-value=0.988) or the InFix screw (p-value=0.991). Both the traditional InFix type screw and the second generation Acumed Acutrak headless compression screws provide adequate fixation during ankle arthrodesis under submaximal loads. There is no demonstrable difference between traditional cannulated partially threaded screws and headless compression screws studied in this model. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  6. Estudo das propriedades mecânicas do ligamento cruzado posterior e do ligamento patelar de cadáveres de seres humanos após utilização de radiofreqüência Study of the mechanical properties of the posterior cruciate ligament and patellar tendon on fresh human cadavers after radiofrequency shrinkage

    Directory of Open Access Journals (Sweden)

    Aline Fazzolari Dota

    2007-01-01

    Full Text Available Este trabalho visou estudar os efeitos da radiofreqüência sobre os ligamentos patelares (LP e ligamentos cruzados posteriores (LCP de cadáveres, levando em conta as características de rigidez e deformação máxima. Foram utilizados 11 LCP e 14 LP, sendo feitas as aferições com o aparelho Kratos® K5002 . Foi realizada a termoabrasão das estruturas, com encurtamento obtido entre 15 e 20% do comprimento inicial. Observou-se que essas deformações (encurtamento não se mantiveram no ensaio pós RF. Conclusão: A radiofreqüência permite o encurtamento do LP e LCP. O encurtamento obtido não se mantém completamente quando os ligamentos são submetidos a cargas tensionais padronizadas neste ensaio biomecânico. O uso de radiofrequência causa redução da rigidez do tecido (LP e LCP.This study intended to examine the effects of radiofrequency shrinkage (RF on patellar ligament (PL and posterior cruciate ligaments (PCL of fresh human cadavers, measuring stiffness and maximum deformation. Eleven PCLs and 14 PLs were studied with traction tests being performed with the aid of a Kratos® K5002 machine. The structures were reduced by 15-20%, after the shrinkage. However, this reduction was partially lost after the traction test. Conclusion: RF was successful in reducing the length of the structures studied, in spite of the statistically significant stiffness loss. Then, RF was not fully successful in maintaining the reduction of ligament length under the traction forces of the test.

  7. Micro-computed tomography assessment of human alveolar bone: bone density and three-dimensional micro-architecture.

    Science.gov (United States)

    Kim, Yoon Jeong; Henkin, Jeffrey

    2015-04-01

    Micro-computed tomography (micro-CT) is a valuable means to evaluate and secure information related to bone density and quality in human necropsy samples and small live animals. The aim of this study was to assess the bone density of the alveolar jaw bones in human cadaver, using micro-CT. The correlation between bone density and three-dimensional micro architecture of trabecular bone was evaluated. Thirty-four human cadaver jaw bone specimens were harvested. Each specimen was scanned with micro-CT at resolution of 10.5 μm. The bone volume fraction (BV/TV) and the bone mineral density (BMD) value within a volume of interest were measured. The three-dimensional micro architecture of trabecular bone was assessed. All the parameters in the maxilla and the mandible were subject to comparison. The variables for the bone density and the three-dimensional micro architecture were analyzed for nonparametric correlation using Spearman's rho at the significance level of p architecture parameters were consistently higher in the mandible, up to 3.3 times greater than those in the maxilla. The most linear correlation was observed between BV/TV and BMD, with Spearman's rho = 0.99 (p = .01). Both BV/TV and BMD were highly correlated with all micro architecture parameters with Spearman's rho above 0.74 (p = .01). Two aspects of bone density using micro-CT, the BV/TV and BMD, are highly correlated with three-dimensional micro architecture parameters, which represent the quality of trabecular bone. This noninvasive method may adequately enhance evaluation of the alveolar bone. © 2013 Wiley Periodicals, Inc.

  8. HISTOLOGICAL STUDY OF HUMAN MAMMARY GLAND IN WOMEN OF NORTH EASTERN REGION OF INDIA

    Directory of Open Access Journals (Sweden)

    Santona

    2015-09-01

    Full Text Available INTRODUCTION: The “mamma” or “breast” is a modified, ectodermal, glandular structure located in the superficial fascia of the anterior chest wall. In female they are evolved to secrete milk for the nourishment of their offspring. They are also present in a rudimentary form in males. MATERIALS AND METHODS: After obtaining institutional ethical clearance t he specimens of human mammary gland were divided into two groups i.e. reproductive (14 to 49 and post - menopausal (50 and above age. The specimens of both the age group were collected from fresh unembalmed human cadaver. The slides were prepared using the standard laboratory procedure. Stained slides were studied for different structures of the mammary gland such as the glandular structures, ducts and myoepithelial cells. Diameters of the ducts were measured in both age groups. The data were analyzed to ca lculate the mean and ‘t’ test was applied to find out the significant difference between mean values. RESULTS: The average diameter of the lactiferous duct as measured by micrometer scale was 2.0 mm and 0.83 mm in reproductive and post - menopausal age group respectively. Calculated value of t’= 4.68. d. f. (degree of freedom =18, P <0.01. Therefore the diameter of lactiferous duct between reproductive and postmenopausal age group differs significantly. DISCUSSION: The results obtained in this study are comp ared with the available established findings of other workers to draw a definite conclusion in the histomorphological aspect of reproductive and postmenopausal age group. CONCLUSION: Though different generations of sophisticated investigations such as mole cular level studies have evolved for the early detection of breast carcinoma, the knowledge of the normal developmental histological changes is most important which will help to detect early abnormal changes of the breast if any

  9. Histomorphologic study of the pituitary glands of Korean cadavers and correlation with computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Kim, Dong Ik; Chung, In Hyuk; Suh, Jung Ho

    1989-01-01

    Histomorphological analysis of the pituitary glands of 62 Korean Adult cadavers was performed, and its results were compared to the findings of high resolution CT scan in 6 cases and magnetic resonance imaging in 2 cases. The CT attenuation density of pituitary glands was also evaluated with coronal scans of 103 normal Korean adults who had no clinical evidence of pituitary abnormalities. The pituitary gland was classified into 4 types based on the contours of superior margin of the glands; slightly convex (type I and type II), slightly concave (type III) and deeply concave (type IV). Among them type III was the most common (44.4%). The size and shape of each lobe of gland were varied. The mean length and height of gland were 10.9 ± 1.4 mm and 4.6 ± 1.2 mm. Rathke's cleft cysts over 0.5 mm in diameter was found in 54.8%, but it rarely exceeded 3 mm in diameter. Rathke's cleft cysts were commonly located at the middle one third between anterior lobe and pars intermedia of pituitary gland. The CT attenuation density of pituitary gland varied depending on the anatomic location and was roughly corresponding to the compactness of cellularity. Focal low attenuation density areas could be consider to represent Rathke's cleft cysts. In one of two pituitary glands, the posterior lobe showed high signal intensity in T1-weighted MRI, which was not corresponding to the intrasellar fat pad or cellularity of gland

  10. Permeation studies of novel terbinafine formulations containing hydrophobins through human nails in vitro.

    Science.gov (United States)

    Vejnovic, Ivana; Huonder, Cornelia; Betz, Gabriele

    2010-09-15

    Existing treatments of onychomycosis are not satisfactory. Oral therapies have many side effects and topical formulations are not able to penetrate into the human nail plate and deliver therapeutical concentrations of active agent in situ. The purpose of the present study was to determine the amount of terbinafine, which permeates through the human nail plate, from liquid formulations containing enhancers, namely hydrophobins A-C in the concentration of 0.1% (w/v). The used reference solution contained 10% (w/v) of terbinafine in 60% (v/v) ethanol/water without enhancer. Permeability studies have been performed on cadaver nails using Franz diffusion cells modified to mount nail plates and filled with 60% (v/v) ethanol/water in the acceptor chamber. Terbinafine was quantitatively determined by HPLC. The amount of terbinafine remaining in the nail was extracted by 96% ethanol from pulverized nail material after permeation experiment and presented as percentage of the dry nail weight before the milling test. Permeability coefficient (PC) of terbinafine from reference solution was determined to be 1.52E-10 cm/s. Addition of hydrophobins improved PC in the range of 3E-10 to 2E-9 cm/s. Remaining terbinafine reservoir in the nail from reference solution was 0.83% (n=2). An increase of remaining terbinafine reservoir in the nail was observed in two out of three tested formulations containing hydrophobins compared to the reference. In all cases, known minimum inhibitory concentration of terbinafine for dermatophytes (0.003 microg/ml) has been exceeded in the acceptor chamber of the diffusion cells. All tested proteins (hydrophobins) facilitated terbinafine permeation after 10 days of permeation experiment, however one of them achieved an outstanding enhancement factor of 13.05 compared to the reference. Therefore, hydrophobins can be included in the list of potential enhancers for treatment of onychomycosis. Copyright 2010 Elsevier B.V. All rights reserved.

  11. MR patterns of rotator cuff impingement lesions and histopathologic correlation of cadaver tendons

    International Nuclear Information System (INIS)

    Rafii, M.; Firooznia, H.; Minkoff, J.; Sherman, O.; Schinella, R.; Weinreb, J.C.; Golimbu, C.; Zazlav, K.

    1989-01-01

    This paper reports shoulder MR examinations of 250 patients retrospectively evaluated and correlated with surgical/arthrographic results in 68 patients and with clinical data in all for assessment of the signal pattern and the configuration of rotator cuff lesions. MR-histopathologic evaluation of the supraspinatus tendon of 8 cadaver shoulders was also correlated with these findings. MR imaging had a sensitivity of 92% in the diagnosis of cuff tears. The most common and accurate criterion for a tear was a tendinous defect, characterized by intense signal on T2-weighted images; less often the torn region consisted of an extremely degenerated and attenuated tendon or was obscured by scar. Presence of secondary findings was mandatory for diagnosis in the latter group. Signal pattern associated with tendonitis varied, and in some simulated that of tendon degeneration (fatty infiltration and fibrillation) or cellular proliferation observed on anatomic specimens. Associated tendinous enlargement and subacromial-subdeltoid bursitis in these patients best correlated with the severity of clinical and surgical findings

  12. A Comparison of Computed Tomographic, Radiographic, Gross and Histological, Dental, and Alveolar Findings in 30 Abnormal Cheek Teeth from Equine Cadavers.

    Science.gov (United States)

    Liuti, Tiziana; Smith, Sionagh; Dixon, Padraic M

    2017-01-01

    Equine cheek teeth disorders, especially pulpar/apical infections, can have very serious consequences due to the frequent extension of infection to the supporting bones and/or adjacent paranasal sinuses. Limited studies have assessed the accuracy of computed tomographic (CT) imaging in the diagnosis of these disorders, and no study has directly compared imaging and pathological findings of the alveoli of diseased equine cheek teeth. To validate the accuracy of CT and radiographic imaging of cheek teeth disorders by comparing CT and radiographic imaging, gross and histological findings in abnormal cheek teeth and their alveoli extracted from equine cadaver heads. Ex vivo original study. Fifty-four cadaver heads from horses with unknown histories that had died or been euthanized on humane grounds obtained from a rendering plant had radiography, CT imaging, and gross pathological examinations performed. Based on imaging and gross examination findings, 30 abnormal cheek teeth (26 maxillary and 4 mandibular) identified in 26 heads were extracted along with their dental alveoli where possible, and further CT imaging, gross, and histological examinations were performed. Eight maxillary cheek teeth (including four with attached alveolar bone) from these heads, that were normal on gross and CT examinations, were used as controls. Gross pathological and histological examinations indicated that 28/30 teeth, including two supernumerary teeth, had pulpar/apical infection, including pulpar and apical changes. A further supernumerary and a dysplastic tooth were also identified. Abnormal calcified tissue architecture was present in all three supernumerary and in the dysplastic tooth. CT imaging strongly indicated the presence of pulpar/apical infection in 27 of the 28 (96.4%) pulpar/apically infected teeth, including the presence of intrapulpar gas ( N  = 19/28), apical clubbing ( N  = 20), periapical halo ( N  = 4), root lysis or fragmentation ( N  = 7), and

  13. Astrocitary niches in human adult medulla oblongata.

    Science.gov (United States)

    Rusu, Mugurel Constantin; Dermengiu, Dan; Loreto, Carla; Motoc, Andrei Gheorghe Marius; Pop, Elena

    2013-04-01

    Astrocytes are considered as neuromodulators of the CNS. Whereas experimental studies on astrocitary functions are gaining importance, the anatomy of the astrocitary niches in the human CNS has been overlooked. The study was performed on the brainstem of 10 adult cadavers. We aimed to determine astrocitary niches in the human medulla oblongata using immunohistochemical labeling with vimentin and also CD34 immunostaining to accurately diagnose associated microvessels. Niches rich in astrocytes were identified as follows: (a) the superficial layer of astrocytes, ventral and ventrolateral, in the rostral medulla oblongata; (b) the median raphe; (c) medullary nuclei: arcuate nucleus, area postrema, nucleus of the solitary tract; (d) the subependymal zone (SEZ, caudal medulla) and subventricular zone (SVZ, rostral medulla). Astrocytes were scarce in the ventrolateral medulla, and mostly present within the pyramidal tract and the olivary nucleus. Apart from the SEZ and SVZ, the brainstem niches of astrocytes mostly overlap those regions known to perform roles as central respiratory chemoreceptors. The astrocytes of the SEZ and SVZ, which are known as stem cell niches, are related to an increased microvascular density. Copyright © 2012 Elsevier GmbH. All rights reserved.

  14. Sex differences in the branching position of the nerve to the abductor digiti minimi muscle: an anatomical study of cadavers.

    Science.gov (United States)

    Mizuno, Daisuke; Naito, Munekazu; Hayashi, Shogo; Ohmichi, Yusuke; Ohmichi, Mika; Nakano, Takashi

    2015-01-01

    The nerve to the abductor digiti minimi muscle (ADMM nerve) is the first branch of the lateral plantar nerve or originates directly from the posterior tibial nerve. Damage to the ADMM nerve is a cause of heel pain and eventually results in ADMM atrophy. It is known that ADMM atrophy occurs more often in females than in males, and the reason remains unclear. This study aimed to explore sex differences in the branching pattern, position, and angle of the ADMM nerve. Forty-two cadavers (20 males, 22 females) were dissected at Aichi Medical University between 2011 and 2015. Cases of foot deformity or atrophy were excluded and 67 ft (30 male, 37 female) were examined to assess the branching pattern, position, and angle of the ADMM nerve. The branching positions of the ADMM nerve were superior to the malleolar-calcaneal axis (MCA) in 37 ft (55 %), on the MCA in 10 ft (15 %), and inferior to the MCA in 20 ft (30 %). There was no case among male feet in which the ADMM nerve branched inferior to the MCA, whereas this pattern was observed in 19 of 37 female feet (51 %). The branching position of the ADMM nerve was significantly closer to the MCA in female feet than in male feet. There were no significant sex differences in the branching pattern and angle of the ADMM nerve. The ADMM nerve sometimes branches off inferior to the MCA in females, but not in males. This difference may be the reason for the more frequent occurrence of ADMM atrophy in females than in males.

  15. Lower pole anatomy and mid-renal-zone classification applied to flexible ureteroscopy: experimental study using human three-dimensional endocasts.

    Science.gov (United States)

    Marroig, Bruno; Favorito, Luciano Alves; Fortes, Marco A; Sampaio, Francisco J B

    2015-12-01

    The aim of this study was to analyze the anatomy of the inferior pole collecting system and the mid-renal-zone classification in human endocasts applied to flexible ureteroscopy. 170 three-dimensional polyester resin endocasts of the kidney collecting system were obtained from 85 adult cadavers. We divided the endocasts into four groups: A1--kidney midzone (KM), drained by minor calices (mc) that are dependent on the superior or the inferior caliceal groups; A2--KM drained by crossed calices; B1--KM drained by a major caliceal group independent of both the superior and inferior groups; and B2--KM drained by mc entering directly into the renal pelvis. We studied the number of calices, the angle between the lower infundibulum and renal pelvis and the angle between the lower infundibulum and the inferior mc (LIICA). Means were statistically compared using ANOVA and the unpaired T test (p kidney midzone drained by minor calices that are dependent on the superior or on the inferior caliceal groups presented at least two restrictive anatomical features. The mid-renal-zone classification was predictive of anatomical risk factors for lower pole ureteroscopy difficulties.

  16. Investigation into Seasonal Scavenging Patterns of Raccoons on Human Decomposition.

    Science.gov (United States)

    Jeong, Yangseung; Jantz, Lee Meadows; Smith, Jake

    2016-03-01

    Although raccoons are known as one of the most common scavengers in the U.S., scavenging by these animals has seldom been studied in terms of forensic significance. In this research, the seasonal pattern of raccoon scavenging and its effect on human decomposition was investigated using 178 human cadavers placed at the Anthropological Research Facility (ARF) of the University of Tennessee, Knoxville (UTK) between February 2011 and December 2013. The results reveal that (i) the frequency of scavenging increases during summer, (ii) scavenging occurs relatively immediately and lasts shorter in summer months, and (iii) scavenging influences the decomposition process by hollowing limbs and by disturbing insect activities, both of which eventually increases the chance of mummification on the affected body. This information is expected to help forensic investigators identify raccoon scavenging as well as make a more precise interpretation of the effect of raccoon scavenging on bodies at crime scenes. © 2015 American Academy of Forensic Sciences.

  17. Electron microscopy of human peripheral nerves of clinical relevance to the practice of nerve blocks. A structural and ultrastructural review based on original experimental and laboratory data.

    Science.gov (United States)

    Reina, M A; Arriazu, R; Collier, C B; Sala-Blanch, X; Izquierdo, L; de Andrés, J

    2013-12-01

    The goal is to describe the ultrastructure of normal human peripheral nerves, and to highlight key aspects that are relevant to the practice of peripheral nerve block anaesthesia. Using samples of sciatic nerve obtained from patients, and dural sac, nerve root cuff and brachial plexus dissected from fresh human cadavers, an analysis of the structure of peripheral nerve axons and distribution of fascicles and topographic composition of the layers that cover the nerve is presented. Myelinated and unmyelinated axons, fascicles, epineurium, perineurium and endoneurium obtained from patients and fresh cadavers were studied by light microscopy using immunohistochemical techniques, and transmission and scanning electron microscopy. Structure of perineurium and intrafascicular capillaries, and its implications in blood-nerve barrier were revised. Each of the anatomical elements is analyzed individually with regard to its relevance to clinical practice to regional anaesthesia. Routine practice of regional anaesthetic techniques and ultrasound identification of nerve structures has led to conceptions, which repercussions may be relevant in future applications of these techniques. In this regard, the ultrastructural and histological perspective accomplished through findings of this study aims at enlightening arising questions within the field of regional anaesthesia. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  18. Advertising cadavers in the republic of letters: anatomical publications in the early modern Netherlands.

    Science.gov (United States)

    Margócsy, Dániel

    2009-06-01

    This paper sketches how late seventeenth-century Dutch anatomists used printed publications to advertise their anatomical preparations, inventions and instructional technologies to an international clientele. It focuses on anatomists Frederik Ruysch (1638-1732) and Lodewijk de Bils (1624-69), inventors of two separate anatomical preparation methods for preserving cadavers and body parts in a lifelike state for decades or centuries. Ruysch's and de Bils's publications functioned as an 'advertisement' for their preparations. These printed volumes informed potential customers that anatomical preparations were aesthetically pleasing and scientifically important but did not divulge the trade secrets of the method of production. Thanks to this strategy of non-disclosure and advertisement, de Bils and Ruysch could create a well-working monopoly market of anatomical preparations. The 'advertising' rhetorics of anatomical publications highlight the potential dangers of equating the growth of print culture with the development of an open system of knowledge exchange.

  19. Too Fresh Is Unattractive! The Attraction of Newly Emerged Nicrophorus vespilloides Females to Odour Bouquets of Large Cadavers at Various Stages of Decomposition

    OpenAIRE

    von Hoermann, Christian; Steiger, Sandra; M?ller, Josef K.; Ayasse, Manfred

    2013-01-01

    The necrophagous burying beetle Nicrophorus vespilloides reproduces on small carcasses that are buried underground to serve as food for their offspring. Cadavers that are too large to bury have previously been postulated to be important food sources for newly emerged beetles; however, the attractiveness of distinct successive stages of decomposition were not further specified. Therefore, we investigated the potential preference of newly emerged N. vespilloides females for odour bouquets of pi...

  20. Preclinical cadaveric study of transanal endoscopic da Vinci® surgery.

    Science.gov (United States)

    Hompes, R; Rauh, S M; Hagen, M E; Mortensen, N J

    2012-08-01

    Single-port platforms are increasingly being used for transanal surgery and may be associated with a shorter learning curve than transanal endoscopic microsurgery. However, these procedures remain technically challenging, and robotic technology could overcome some of the limitations and increase intraluminal manoeuvrability. An initial experimental experience with transanal endoscopic da Vinci(®) surgery (TEdS) using a glove port on human cadavers is reported. After initial dry laboratory experiments, the feasibility of TEdS and ideal set-up were further evaluated in human cadavers. For transanal access a glove port was constructed on-table by using a circular anal dilator, a standard wound retractor and a surgical glove. A da Vinci(®) Si HD system was used in combination with the glove port for transanal endoscopic resections. It was possible to perform all necessary tasks to complete a full-thickness excision and closure of the rectal wall, with cadavers in both prone and supine positions. The stable magnified view, combined with the EndoWrist(®) technology of the robotic instruments, made every task straightforward. Intraluminal manoeuvrability could be improved further by intersecting the robotic instruments. The glove port proved to be very reliable and the inherent flexibility of the glove facilitated docking of the robotic arms in a narrow confined space. Using a reliable and universally available glove port, TEdS was feasible and a preferred set-up was determined. Further clinical trials will be necessary to assess the safety and efficacy of this technique. Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.

  1. An Experimental Study to Measure the Mechanical Properties of the Human Liver.

    Science.gov (United States)

    Karimi, Alireza; Shojaei, Ahmad

    2018-01-01

    Since the liver is one of the most important organs of the body that can be injured during trauma, that is, during accidents like car crashes, understanding its mechanical properties is of great interest. Experimental data is needed to address the mechanical properties of the liver to be used for a variety of applications, such as the numerical simulations for medical purposes, including the virtual reality simulators, trauma research, diagnosis objectives, as well as injury biomechanics. However, the data on the mechanical properties of the liver capsule is limited to the animal models or confined to the tensile/compressive loading under single direction. Therefore, this study was aimed at experimentally measuring the axial and transversal mechanical properties of the human liver capsule under both the tensile and compressive loadings. To do that, 20 human cadavers were autopsied and their liver capsules were excised and histologically analyzed to extract the mean angle of a large fibers population (bundle of the fine collagen fibers). Thereafter, the samples were cut and subjected to a series of axial and transversal tensile/compressive loadings. The results revealed the tensile elastic modulus of 12.16 ± 1.20 (mean ± SD) and 7.17 ± 0.85 kPa under the axial and transversal loadings respectively. Correspondingly, the compressive elastic modulus of 196.54 ± 13.15 and 112.41 ± 8.98 kPa were observed under the axial and transversal loadings respectively. The compressive axial and transversal maximum/failure stress of the capsule were 32.54 and 37.30 times higher than that of the tensile ones respectively. The capsule showed a stiffer behavior under the compressive load compared to the tensile one. In addition, the axial elastic modulus of the capsule was found to be higher than that of the transversal one. The findings of the current study have implications not only for understanding the mechanical properties of the human capsule tissue under tensile

  2. Transoral robotic thyroidectomy: a preclinical feasibility study using the da Vinci Xi platform.

    Science.gov (United States)

    Russell, Jonathon O; Noureldine, Salem I; Al Khadem, Mai G; Chaudhary, Hamad A; Day, Andrew T; Kim, Hoon Yub; Tufano, Ralph P; Richmon, Jeremy D

    2017-09-01

    Transoral thyroid surgery allows the surgeon to conceal incisions within the oral cavity without significantly increasing the amount of required dissection. TORT provides an ideal scarless, midline access to the thyroid gland and bilateral central neck compartments. This approach, however, presents multiple technical challenges. Herein, we present our experience using the latest generation robotic surgical system to accomplish transoral robotic thyroidectomy (TORT). In two human cadavers, the da Vinci Xi surgical system (Intuitive Surgical, Sunnyvale, CA, USA) was used to complete TORT. Total thyroidectomy and bilateral central neck dissection was successfully completed in both cadavers. The da Vinci Xi platform offered several technologic advantages over previous robotic generations including overhead docking, narrower arms, and improved range of motion allowing for improved execution of previously described TORT techniques.

  3. A prática anatômica e a formação médica

    Directory of Open Access Journals (Sweden)

    Liana Albernaz de Melo Bastos

    2000-06-01

    Full Text Available Medical education is committed to a distant and impersonal model of medical care that does not take into consideration the complexity of the encounter between physician and patient. Some authors believe that the "dehumanizing posture" of physicians is encouraged by the pedagogical practice of dissecting cadavers. In this sense the relationship between student and cadaver would be a model preceding and shaping the relationship between physician and patient. This article describes a study on the impact of anatomy practice on first-semester medical students enrolled in the anatomy course at the Federal University of Rio de Janeiro, Brazil. Groups of 16 students attended four 1-hour meetings over the semester. Thirty-two groups were assessed over four semesters, with a total of 384 students. The activity was coordinated by medical psychology and anatomy professors, who took notes during the sessions. At the end of each semester the students filled out a questionnaire to help evaluate this teaching activity. In the groups, the most frequent themes were the first encounter with the cadaver, respect for the cadaver, and the presence or absence of humanity in the cadaver. In general the questionnaire showed that the students found the experience to be positive. We believe that the pedagogical activity described here provides an opportunity to reverse the gloomy state of affairs of dehumanized medical care. Group discussions help decrease students' anxiety with the cadaver. This in turn results in a more humane model for the physician-patient relationship and promotes change in the ideology of coldness and distance on the part of the physician. The paradox of medical education--being technical and also having to take into account the complexity of human relationships--can be resolved through activities such as this one.

  4. A prática anatômica e a formação médica

    Directory of Open Access Journals (Sweden)

    Bastos Liana Albernaz de Melo

    2000-01-01

    Full Text Available Medical education is committed to a distant and impersonal model of medical care that does not take into consideration the complexity of the encounter between physician and patient. Some authors believe that the "dehumanizing posture" of physicians is encouraged by the pedagogical practice of dissecting cadavers. In this sense the relationship between student and cadaver would be a model preceding and shaping the relationship between physician and patient. This article describes a study on the impact of anatomy practice on first-semester medical students enrolled in the anatomy course at the Federal University of Rio de Janeiro, Brazil. Groups of 16 students attended four 1-hour meetings over the semester. Thirty-two groups were assessed over four semesters, with a total of 384 students. The activity was coordinated by medical psychology and anatomy professors, who took notes during the sessions. At the end of each semester the students filled out a questionnaire to help evaluate this teaching activity. In the groups, the most frequent themes were the first encounter with the cadaver, respect for the cadaver, and the presence or absence of humanity in the cadaver. In general the questionnaire showed that the students found the experience to be positive. We believe that the pedagogical activity described here provides an opportunity to reverse the gloomy state of affairs of dehumanized medical care. Group discussions help decrease students' anxiety with the cadaver. This in turn results in a more humane model for the physician-patient relationship and promotes change in the ideology of coldness and distance on the part of the physician. The paradox of medical education--being technical and also having to take into account the complexity of human relationships--can be resolved through activities such as this one.

  5. Immunohistochemical profile of VEGF, TGF-β and PGE₂ in human pterygium and normal conjunctiva: experimental study and review of the literature.

    Science.gov (United States)

    Bianchi, E; Scarinci, F; Grande, C; Plateroti, R; Plateroti, P; Plateroti, A M; Fumagalli, L; Capozzi, P; Feher, J; Artico, M

    2012-01-01

    Human pterygium is made up of chronic proliferative fibro-vascular tissue growing on the ocular surface. This disease exhibits both degenerative and hyperplastic properties. Some fibroangiogenic factors have recently been shown to play a potential role in fibrovascular diseases via the angiogenesis process. The aim of this study is to evaluate VEGF, TGF-β and PGE₂ expression in the epithelial, endothelial and stromal cells of human pterygium and normal conjunctiva in order to determine whether these factors participate in the development of pterygium. Ten specimens from patients with pterygium and two normal conjunctivas (cadavers) were analyzed by immunohistochemistry using specific antibodies against these growth factors. The technique used was ABC/HRP (Avidin complexed with biotinylated peroxidase). Immunoreactivity of VEGF was significantly increased in the epithelium, vascular endothelium and stromal cells in primary pterygium as compared with normal conjunctiva. A moderate expression of TGF-β in the pterygium was observed in the epithelial and stromal layers. On the contrary, immunolabeling of this growth factor in the human normal conjunctiva was weak. PGE₂ was strongly expressed in the epithelium of patients with pterygium, as in control conjunctival tissues, and the immunolabeling was moderate in the stroma from the same patients. Our results suggest that these growth factors may contribute to the progression of primary pterygium by increasing angiogenesis, thus leading to the formation of new blood vessels from the pre-existing vasculature. We conclude that VEGF, TGF-β and PGE₂ may be potential therapeutic targets in the treatment of this disease although proof of this evidence requires further studies.

  6. Microbial communities associated with human decomposition and their potential use as postmortem clocks.

    Science.gov (United States)

    Finley, Sheree J; Benbow, M Eric; Javan, Gulnaz T

    2015-05-01

    Most forensic research that is used to better understand how to estimate the postmortem interval (PMI) entails the study of the physiochemical characteristics of decomposition and the effects that environmental factors have on the decomposition process. Forensic entomology exploits the life cycles of arthropods like Diptera (blow flies or flesh flies) and Coleoptera (beetles) deposited on the decaying carcass to determine PMI. Forensic taphonomy, from the Greek word taphos meaning burial, studies the creation of the fossils of decomposed cadavers to ascertain information as to the nature and time of death. Compared to other areas of taphonomy, there have been relatively few forensic science studies that have investigated the impact of human decomposition on the microbial changes occurring on or in a corpse or in the soil communities underneath a body. Such research may facilitate the critical determination of PMI. Therefore, the scope of this review is to provide a concise summary of the current progress in the newly emerging field of microbial diversity and the next-generation metagenomic sequencing approaches for assessing these communities in humans and in the soil beneath decomposing human.

  7. Elongamento do enxerto de tendões do músculo grácial e semitendinoso humanos: estudo realizado em cadáveres de adultos jovens Graft semitendinosus and gracilis human muscle tendons elongation: a study carried out on young adult human cadavers

    Directory of Open Access Journals (Sweden)

    Sérgio Rocha Piedade

    2005-01-01

    Full Text Available Na cirurgia de reconstrução do ligamento cruzado anterior do joelho, os enxertos de tendões autólogos são a principal opção como substitutos ligamentares. Entretanto, uma das razões da falha da reconstrução ligamentar com tecidos moles é o estiramento ou elongamento do enxerto com o tempo. Neste trabalho, foram ensaiados oito tendões do músculo grácil e oito do músculo semitendinoso humanos, obtidos de quatro cadáveres do sexo masculino, com idade média de 24,5 anos. Cada tendão foi submetido a uma deformação relativa constante de 2,5% durante 600 s, com registro contínuo do relaxamento de força. A seguir, o tendão retornava ao seu comprimento inicial e era mantido num período de repouso de 300 s. Após este intervalo, um segundo ensaio, semelhante ao primeiro, era realizado. A velocidade de carregamento empregada foi de 10% do comprimento inicial do corpo de prova por segundo. Foram obtidos valores de força inicial, com 300 s e 600 s nos dois ensaios. A análise estatística sugere um comportamento mecânico mais uniforme para o tendão do músculo semitendinoso quando comparado ao tendão do músculo grácil.In the anterior cruciate ligament knee surgery reconstruction, autologous tendons graft remains as a main option as substitutive ligaments. However time effect on graft elongation is the main reason of ligament reconstruction failure. Traction tests have been performed on eight gracilis as well as on eight semitendinosus human muscles tendons obtained from four male cadavers at an average of 24.5 years. Each tendon specimen has been submitted to a deformation of 2.5% of its initial length for a time interval of 600 s with continuous recording of the corresponding force relaxation. The tendon specimen was then kept at rest for 300 s as soon as it returned to its initial length. The same specimen was then submitted to a similar test. Deformation rate for both tests was 10% of its initial length per second. Initial

  8. An incidence study on thyroglossal duct cysts in adults

    International Nuclear Information System (INIS)

    Kurt, A.; Ortug, C.; Aydar, Y.; Ortug, G.

    2007-01-01

    To investigate the incidence of the asymptomatic thyroglossal duct anomalies and to review the literature and make comments on the significance of this condition. A total of 80 cadavers were dissected in the present study. This study was carried out during 2005, where the cadavers were randomly included from the criminal laboratories of the Ministry of Justice, Republic of Turkey in Istanbul. None of the cadavers had laryngeal and cervical injuries resulting from a trauma or the cause of their death. The examined cadavers included 59 men and 21 females, and their ages were ranged from 35-80 years old. The larynges were removed and fixed in 10% formalin and then dissected. The sections were examined using surgical SMZ 10 Nikon stereomicroscope. We evaluated the presence, localization and diameter of the cysts with regard to age and sex of the cadavers. We observed a total of 12 different localization of thyroglossal ducts and cysts among the 80 dissected cadavers. Ten of these ducts cysts were found in males with an age range of 35-68 years and 2 female cadavers aged 45-65 years. In 6 cases, the thyroglossal ducts and cysts were located in the left of the midline of the neck, while 3 cases were from the right of the midline, and the remaining was located on the midline of the neck. In all cases, thryoglossal ducts and cysts were complete and restricted to the infrahyoid region: all of them had connection with the hyoid bone, but not with the perichondrium of the cartilage. In addition, the thyroglossal ducts have connection with the left lobe of the thyroid glands in 3 cases, one case in the right lobe, and 2 cases with the isthmus of the thyroid gland. Finally in 5 cases thyroglossal ducts were complete and had well developed cysts. Thyroglossal duct remnants are one of the most often seen congenital asymptomatic masses of the neck region (7%). The presence of these duct remnants may lead to abnormal phonation and epithelial carcinomas. Therefore, correlation of

  9. Comparison of the diagnostic accuracy of FBP, ASiR, and MBIR reconstruction during CT angiography in the evaluation of a vessel phantom with calcified stenosis in a distal superficial femoral artery in a cadaver extremity.

    Science.gov (United States)

    Tsukada, Jitsuro; Yamada, Minoru; Yamada, Yoshitake; Yamazaki, Shun; Imanishi, Nobuaki; Tamura, Kentaro; Hashimoto, Masahiro; Nakatsuka, Seishi; Jinzaki, Masahiro

    2016-07-01

    To investigate whether adaptive statistical iterative reconstruction (ASiR) or model-based iterative reconstruction (MBIR) improves the diagnostic performance of computed tomography angiography (CTA) for small-vessel calcified lesions relative to filtered back projection (FBP) using cadaver extremities and a calcified stenosis phantom. A cadaver was used in accordance with our institutional regulations, and a calcified stenosis phantom simulating 4 grades of stenosis was prepared. The phantom was inserted within the distal superficial femoral artery of the cadaver leg. Ten CT images per reconstruction type and stenosis grade were acquired using a 64-slice multidetector-row CTA.As an objective measurement, the first and second derivatives of the CT value function profiles were calculated. As a subjective measurement, 2 blinded reviewers measured the stenosis ratio using a quantitative scale. The Wilcoxon rank-sum test was used to evaluate the data. Objective measurements of both 25% and 50% stenosis differed significantly (P ASiR and FBP.Reviewer 2's subjective measurements of 25% stenosis differed significantly (P ASiR (40.89 ± 3.14%), and the measurements of 50% stenosis differed significantly (P ASiR and FBP. MBIR improves the diagnostic performance of CTA for small-vessel calcified lesions relative to FBP.

  10. Computational modeling to predict mechanical function of joints: application to the lower leg with simulation of two cadaver studies.

    Science.gov (United States)

    Liacouras, Peter C; Wayne, Jennifer S

    2007-12-01

    Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as predictive devices for understanding joint function and serve as clinical tools for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading. Three-dimensional computational models of the lower leg were created to illustrate the application of this new approach. Model development began with generating three-dimensional surfaces of each bone from CT images and then importing into the three-dimensional solid modeling software SOLIDWORKS and motion simulation package COSMOSMOTION. Through SOLIDWORKS and COSMOSMOTION, each bone surface file was filled to create a solid object and positioned necessary components added, and simulations executed. Three-dimensional contacts were added to inhibit intersection of the bones during motion. Ligaments were represented as linear springs. Model predictions were then validated by comparison to two different cadaver studies, syndesmotic injury and repair and ankle inversion following ligament transection. The syndesmotic injury model was able to predict tibial rotation, fibular rotation, and anterior/posterior displacement. In the inversion simulation, calcaneofibular ligament extension and angles of inversion compared well. Some experimental data proved harder to simulate accurately, due to certain software limitations and lack of complete experimental data. Other parameters that could not be easily obtained experimentally can be predicted and analyzed by the computational simulations. In the syndesmotic injury study, the force generated in the tibionavicular and calcaneofibular ligaments reduced with the insertion of the staple, indicating how this repair technique changes joint function. After transection of the calcaneofibular

  11. Use of Eye Tracking as an Innovative Instructional Method in Surgical Human Anatomy.

    Science.gov (United States)

    Sánchez-Ferrer, María Luísa; Grima-Murcia, María Dolores; Sánchez-Ferrer, Francisco; Hernández-Peñalver, Ana Isabel; Fernández-Jover, Eduardo; Sánchez Del Campo, Francisco

    Tobii glasses can record corneal infrared light reflection to track pupil position and to map gaze focusing in the video recording. Eye tracking has been proposed for use in training and coaching as a visually guided control interface. The aim of our study was to test the potential use of these glasses in various situations: explanations of anatomical structures on tablet-type electronic devices, explanations of anatomical models and dissected cadavers, and during the prosection thereof. An additional aim of the study was to test the use of the glasses during laparoscopies performed on Thiel-embalmed cadavers (that allows pneumoinsufflation and exact reproduction of the laparoscopic surgical technique). The device was also tried out in actual surgery (both laparoscopy and open surgery). We performed a pilot study using the Tobii glasses. Dissection room at our School of Medicine and in the operating room at our Hospital. To evaluate usefulness, a survey was designed for use among students, instructors, and practicing physicians. The results were satisfactory, with the usefulness of this tool supported by more than 80% positive responses to most questions. There was no inconvenience for surgeons and that patient safety was ensured in the real laparoscopy. To our knowledge, this is the first publication to demonstrate the usefulness of eye tracking in practical instruction of human anatomy, as well as in teaching clinical anatomy and surgical techniques in the dissection and operating rooms. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  12. Terrestrial laser scanning and a degenerated cylinder model to determine gross morphological change of cadavers under conditions of natural decomposition.

    Science.gov (United States)

    Zhang, Xiao; Glennie, Craig L; Bucheli, Sibyl R; Lindgren, Natalie K; Lynne, Aaron M

    2014-08-01

    Decomposition can be a highly variable process with stages that are difficult to quantify. Using high accuracy terrestrial laser scanning a repeated three-dimensional (3D) documentation of volumetric changes of a human body during early decomposition is recorded. To determine temporal volumetric variations as well as 3D distribution of the changed locations in the body over time, this paper introduces the use of multiple degenerated cylinder models to provide a reasonable approximation of body parts against which 3D change can be measured and visualized. An iterative closest point algorithm is used for 3D registration, and a method for determining volumetric change is presented. Comparison of the laser scanning estimates of volumetric change shows good agreement with repeated in-situ measurements of abdomen and limb circumference that were taken diurnally. The 3D visualizations of volumetric changes demonstrate that bloat is a process with a beginning, middle, and end rather than a state of presence or absence. Additionally, the 3D visualizations show conclusively that cadaver bloat is not isolated to the abdominal cavity, but also occurs in the limbs. Detailed quantification of the bloat stage of decay has the potential to alter how the beginning and end of bloat are determined by researchers and can provide further insight into the effects of the ecosystem on decomposition. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Magnetic resonance imaging susceptibility artifacts in the cervical vertebrae and spinal cord related to monocortical screw-polymethylmethacrylate implants in canine cadavers.

    Science.gov (United States)

    Jones, Brian G; Fosgate, Geoffrey T; Green, Eric M; Habing, Amy M; Hettlich, Bianca F

    2017-04-01

    OBJECTIVE To characterize and compare MRI susceptibility artifacts related to titanium and stainless steel monocortical screws in the cervical vertebrae and spinal cord of canine cadavers. SAMPLE 12 canine cadavers. PROCEDURES Cervical vertebrae (C4 and C5) were surgically stabilized with titanium or stainless steel monocortical screws and polymethylmethacrylate. Routine T1-weighted, T2-weighted, and short tau inversion recovery sequences were performed at 3.0 T. Magnetic susceptibility artifacts in 20 regions of interest (ROIs) across 4 contiguous vertebrae (C3 through C6) were scored by use of an established scoring system. RESULTS Artifact scores for stainless steel screws were significantly greater than scores for titanium screws at 18 of 20 ROIs. Artifact scores for titanium screws were significantly higher for spinal cord ROIs within the implanted vertebrae. Artifact scores for stainless steel screws at C3 were significantly less than at the other 3 cervical vertebrae. CONCLUSIONS AND CLINICAL RELEVANCE Evaluation of routine MRI sequences obtained at 3.0 T revealed that susceptibility artifacts related to titanium monocortical screws were considered mild and should not hinder the overall clinical assessment of the cervical vertebrae and spinal cord. However, mild focal artifacts may obscure small portions of the spinal cord or intervertebral discs immediately adjacent to titanium screws. Severe artifacts related to stainless steel screws were more likely to result in routine MRI sequences being nondiagnostic; however, artifacts may be mitigated by implant positioning.

  14. Development and validation of a computational model to study the effect of foot constraint on ankle injury due to external rotation.

    Science.gov (United States)

    Wei, Feng; Hunley, Stanley C; Powell, John W; Haut, Roger C

    2011-02-01

    Recent studies, using two different manners of foot constraint, potted and taped, document altered failure characteristics in the human cadaver ankle under controlled external rotation of the foot. The posterior talofibular ligament (PTaFL) was commonly injured when the foot was constrained in potting material, while the frequency of deltoid ligament injury was higher for the taped foot. In this study an existing multibody computational modeling approach was validated to include the influence of foot constraint, determine the kinematics of the joint under external foot rotation, and consequently obtain strains in various ligaments. It was hypothesized that the location of ankle injury due to excessive levels of external foot rotation is a function of foot constraint. The results from this model simulation supported this hypothesis and helped to explain the mechanisms of injury in the cadaver experiments. An excessive external foot rotation might generate a PTaFL injury for a rigid foot constraint, and an anterior deltoid ligament injury for a pliant foot constraint. The computational models may be further developed and modified to simulate the human response for different shoe designs, as well as on various athletic shoe-surface interfaces, so as to provide a computational basis for optimizing athletic performance with minimal injury risk.

  15. The Pedicled Buccal Fat Pad: Anatomical Study of the New Flap for Skull Base Defect Reconstruction After Endoscopic Endonasal Transpterygoid Surgery

    Science.gov (United States)

    Golbin, Denis A.; Lasunin, Nikolay V.; Cherekaev, Vasily A.; Polev, Georgiy A.

    2016-01-01

    Objectives To evaluate the efficacy and safety of using a buccal fat pad for endoscopic skull base defect reconstruction. Design Descriptive anatomical study with an illustrative case presentation. Setting Anatomical study was performed on 12 fresh human cadaver specimens with injected arteries (24 sides). Internal carotid artery was exposed in the coronal plane via the endoscopic transpterygoid approach. The pedicled buccal fat pad was used for reconstruction. Participants: 12 human cadaver head specimens; one patient operated using the proposed technique. Main outcome measures: Proximity of the buccal fat pad flap to the defect, compliance of the flap, comfort and safety of harvesting procedure, and compatibility with the Hadad–Bassagasteguy nasoseptal flap. Results: Harvesting procedure was performed using anterior transmaxillary corridor. The pedicled buccal fat pad flap can be used to pack the sphenoid sinus or cover the internal carotid artery from cavernous to upper parapharyngeal segment. Conclusion The buccal fat pad can be safely harvested through the same approach without external incisions and is compliant enough to conform to the skull base defect. The proposed pedicled flap can replace free abdominal fat in central skull base reconstruction. The volume of the buccal fat pad allows obliteration of the sphenoid sinus or upper parapharyngeal space. PMID:28180047

  16. Impact of environmental factors on biometric matching during human decomposition

    Energy Technology Data Exchange (ETDEWEB)

    Bolme, David S [ORNL; Tokola, Ryan A [ORNL; Boehnen, Chris Bensing [ORNL; Saul, Tiffany B [ORNL; Sauerwein, Kelly A [ORNL; Steadman, Dawnie W [ORNL

    2016-01-01

    Automatic recognition systems are a valuable tool for identifying unknown deceased individuals. Immediately af- ter death fingerprint and face biometric samples are easy to collect using standard sensors and cameras and can be easily matched to anti-mortem biometric samples. Even though post-mortem fingerprints and faces have been used for decades, there are no studies that track these biomet- rics through the later stages of decomposition to determine the length of time the biometrics remain viable. This paper discusses a multimodal dataset of fingerprints, faces, and irises from 14 human cadavers that decomposed outdoors under natural conditions. Results include predictive models relating time and temperature, measured as Accumulated Degree Days (ADD), and season (winter, spring, summer) to the predicted probably of automatic verification using a commercial algorithm.

  17. From the Cover: Cell-replacement therapy for diabetes: Generating functional insulin-producing tissue from adult human liver cells

    Science.gov (United States)

    Sapir, Tamar; Shternhall, Keren; Meivar-Levy, Irit; Blumenfeld, Tamar; Cohen, Hamutal; Skutelsky, Ehud; Eventov-Friedman, Smadar; Barshack, Iris; Goldberg, Iris; Pri-Chen, Sarah; Ben-Dor, Lya; Polak-Charcon, Sylvie; Karasik, Avraham; Shimon, Ilan; Mor, Eytan; Ferber, Sarah

    2005-05-01

    Shortage in tissue availability from cadaver donors and the need for life-long immunosuppression severely restrict the large-scale application of cell-replacement therapy for diabetic patients. This study suggests the potential use of adult human liver as alternate tissue for autologous beta-cell-replacement therapy. By using pancreatic and duodenal homeobox gene 1 (PDX-1) and soluble factors, we induced a comprehensive developmental shift of adult human liver cells into functional insulin-producing cells. PDX-1-treated human liver cells express insulin, store it in defined granules, and secrete the hormone in a glucose-regulated manner. When transplanted under the renal capsule of diabetic, immunodeficient mice, the cells ameliorated hyperglycemia for prolonged periods of time. Inducing developmental redirection of adult liver offers the potential of a cell-replacement therapy for diabetics by allowing the patient to be the donor of his own insulin-producing tissue. pancreas | transdifferentiation

  18. Exploring metal artifact reduction using dual-energy CT with pre-metal and post-metal implant cadaver comparison: are implant specific protocols needed?

    Science.gov (United States)

    Wellenberg, Ruud H H; Donders, Johanna C E; Kloen, Peter; Beenen, Ludo F M; Kleipool, Roeland P; Maas, Mario; Streekstra, Geert J

    2017-08-25

    To quantify and optimize metal artifact reduction using virtual monochromatic dual-energy CT for different metal implants compared to non-metal reference scans. Dual-energy CT scans of a pair of human cadaver limbs were acquired before and after implanting a titanium tibia plate, a stainless-steel tibia plate and a titanium intramedullary nail respectively. Virtual monochromatic images were analyzed from 70 to 190 keV. Region-of-interest (ROI), used to determine fluctuations and inaccuracies in CT numbers of soft tissues and bone, were placed in muscle, fat, cortical bone and intramedullary tibia canal. The stainless-steel implant resulted in more pronounced metal artifacts compared to both titanium implants. CT number inaccuracies in 70 keV reference images were minimized at 130, 180 and 190 keV for the titanium tibia plate, stainless-steel tibia plate and titanium intramedullary nail respectively. Noise, measured as the standard deviation of pixels within a ROI, was minimized at 130, 150 and 140 keV for the titanium tibia plate, stainless-steel tibia plate and titanium intramedullary nail respectively. Tailoring dual-energy CT protocols using implant specific virtual monochromatic images minimizes fluctuations and inaccuracies in CT numbers in bone and soft tissues compared to non-metal reference scans.

  19. [Attempt to reduce the formaldehyde concentration by blowing cooled fresh air down in to the breathing zone of medical students from an admission port on the ceiling during gross anatomy class].

    Science.gov (United States)

    Takayanagi, Masaaki; Sakai, Makoto; Ishikawa, Youichi; Murakami, Kunio; Kimura, Akihiko; Kakuta, Sachiko; Sato, Fumi

    2008-09-01

    Cadavers in gross anatomy laboratories at most medical schools are conventionally embalmed in formaldehyde solution, which is carcinogenic to humans. Medical students and instructors are thus exposed to formaldehyde vapors emitted from cadavers during dissection. To reduce high formaldehyde concentrations in the breathing zone above cadavers being examined by anatomy medical students provisionally, dissection beds were located under existing admission ports on the ceiling to supply cooled fresh air from the admission port blowing downward on to the cadaver. In all cases, compared to normal condition, the downward flow of cooled fresh air from an admission port reduced formaldehyde concentrations by 0.09-0.98 ppm and reduced to 12.6-65.4% in the air above a cadaver in the breathing zone of students. The formaldehyde concentrations above cadavers under admission ports were not more than the formaldehyde concentrations between beds representing the indoor formaldehyde concentrations. Although the application of an existing admission port on the ceiling in this study did not remove formaldehyde, the downflow of cooled fresh air using this system reduced the formaldehyde concentration in the air above cadavers being attended by anatomy students during dissections. These results suggest the need for reducing formaldehyde levels in gross anatomy laboratories using fundamental countermeasures in order to satisfy the guidelines of 0.08 ppm established by the World Health Organization and the Japan Ministry of Health, Labor and Welfare.

  20. Comparison of Point Placement by Veterinary Professionals with Different Levels of Acupuncture Training in a Canine Cadaver Model.

    Science.gov (United States)

    Yang, Toni; Shmalberg, Justin; Hochman, Lindsay; Miscioscia, Erin; Brumby, Meghan; McKenna, Kelsey; Roth, Amber

    2017-10-01

    Veterinary acupuncture is becoming increasingly implemented for various disease processes, with growing numbers of veterinarians pursuing advanced training to meet the rising demand for this relatively new intervention. Accurate acupoint placement remains challenging, with individual practitioners relying on varying methods of point identification, often compounded by the transpositional nature of points for companion animals. The aim of this study was to assess for differences in acupuncture needle placement of select points between veterinary professionals with three different levels of acupuncture training in an academic teaching environment. Seven participants placed a total of six acupoints on a canine cadaver. Digital radiography was used to document each participant's point placement. Each participant's point location was then compared to a control "correct" point, and the distance between the two points was measured. A significant difference in placement accuracy was identified between the participants when grouped by training level (p = 0.03). These results indicate that veterinary patients receiving acupuncture treatment from veterinarians with different levels of training may subsequently experience varying effects, although further studies are warranted on more specific acupoint description as well as the clinical implications of needle placement accuracy. Copyright © 2017. Published by Elsevier B.V.

  1. In situ measurements of human articular cartilage stiffness by means of a scanning force microscope

    International Nuclear Information System (INIS)

    Imer, Raphael; Akiyama, Terunobu; Rooij, Nico F de; Stolz, Martin; Aebi, Ueli; Kilger, Robert; Friederich, Niklaus F; Wirz, Dieter; Daniels, A U; Staufer, Urs

    2007-01-01

    Osteoarthritis is a painful and disabling progressive joint disease, characterized by degradation of articular cartilage. In order to study this disease at early stages, we have miniaturized and integrated a complete scanning force microscope into a standard arthroscopic device fitting through a standard orthopedic canula. This instrument will allow orthopedic surgeons to measure the mechanical properties of articular cartilage at the nanometer and micrometer scale in-vivo during a standard arthroscopy. An orthopedic surgeon assessed the handling of the instrument. First measurements of the elasticity-modulus of human cartilage were recorded in a cadaver knee non minimal invasive. Second, minimally invasive experiments were performed using arthroscopic instruments. Load-displacement curves were successfully recorded

  2. In situ measurements of human articular cartilage stiffness by means of a scanning force microscope

    Energy Technology Data Exchange (ETDEWEB)

    Imer, Raphael [Institute of Microtechnology, University of Neuchatel, Jaquet-Droz 1, 2007 Neuchatel (Switzerland); Akiyama, Terunobu [Institute of Microtechnology, University of Neuchatel, Jaquet-Droz 1, 2007 Neuchatel (Switzerland); Rooij, Nico F de [Institute of Microtechnology, University of Neuchatel, Jaquet-Droz 1, 2007 Neuchatel (Switzerland); Stolz, Martin [Maurice E. Mueller Institute, University of Basel, Klingelbergstr. 70, 4056 Basel (Switzerland); Aebi, Ueli [Maurice E. Mueller Institute, University of Basel, Klingelbergstr. 70, 4056 Basel (Switzerland); Kilger, Robert [Clinics for Orthopedic Surgery and Traumatology, Kantonsspital, 4101 Bruderholz (Switzerland); Friederich, Niklaus F [Clinics for Orthopedic Surgery and Traumatology, Kantonsspital, 4101 Bruderholz (Switzerland); Wirz, Dieter [Lab. for Orthopaedic Biomechanics, University of Basel, Klingelbergstr. 50-70, 4056 Basel (Switzerland); Daniels, A U [Lab. for Orthopaedic Biomechanics, University of Basel, Klingelbergstr. 50-70, 4056 Basel (Switzerland); Staufer, Urs [Institute of Microtechnology, University of Neuchatel, Jaquet-Droz 1, 2007 Neuchatel (Switzerland)

    2007-03-15

    Osteoarthritis is a painful and disabling progressive joint disease, characterized by degradation of articular cartilage. In order to study this disease at early stages, we have miniaturized and integrated a complete scanning force microscope into a standard arthroscopic device fitting through a standard orthopedic canula. This instrument will allow orthopedic surgeons to measure the mechanical properties of articular cartilage at the nanometer and micrometer scale in-vivo during a standard arthroscopy. An orthopedic surgeon assessed the handling of the instrument. First measurements of the elasticity-modulus of human cartilage were recorded in a cadaver knee non minimal invasive. Second, minimally invasive experiments were performed using arthroscopic instruments. Load-displacement curves were successfully recorded.

  3. Chloroform and trichloroethylene uptake from water into human skin in vitro: Kinetics and risk implications

    International Nuclear Information System (INIS)

    Bogen, K.T.; Keating, G.A.; Vogel, J.S.

    1995-03-01

    A model recently proposed by the US Environmental Protection Agency (EPA) predicts that short-term dermal uptakes of organic environmental water contaminants are proportional to the square root of exposure time. The model appears to underestimate dermal uptake, based on very limited in vivo uptake data obtained primarily using human subjects. To further assess this model, we examined in vitro dermal uptake kinetics for aqueous organic chemicals using accelerator mass spectrometry (AMS). Specifically, we examined the kinetics of in vitro dermal uptake of 14 C-labeled chloroform and trichloroethylene from dilute (5-ppb) aqueous solutions using full-thickness human cadaver skin exposed for (≤1 hr)

  4. Optical spectroscopic characterization of human meniscus biomechanical properties

    Science.gov (United States)

    Ala-Myllymäki, Juho; Danso, Elvis K.; Honkanen, Juuso T. J.; Korhonen, Rami K.; Töyräs, Juha; Afara, Isaac O.

    2017-12-01

    This study investigates the capacity of optical spectroscopy in the visible (VIS) and near-infrared (NIR) spectral ranges for estimating the biomechanical properties of human meniscus. Seventy-two samples obtained from the anterior, central, and posterior locations of the medial and lateral menisci of 12 human cadaver joints were used. The samples were subjected to mechanical indentation, then traditional biomechanical parameters (equilibrium and dynamic moduli) were calculated. In addition, strain-dependent fibril network modulus and permeability strain-dependency coefficient were determined via finite-element modeling. Subsequently, absorption spectra were acquired from each location in the VIS (400 to 750 nm) and NIR (750 to 1100 nm) spectral ranges. Partial least squares regression, combined with spectral preprocessing and transformation, was then used to investigate the relationship between the biomechanical properties and spectral response. The NIR spectral region was observed to be optimal for model development (83.0%≤R2≤90.8%). The percentage error of the models are: Eeq (7.1%), Edyn (9.6%), Eɛ (8.4%), and Mk (8.9%). Thus, we conclude that optical spectroscopy in the NIR range is a potential method for rapid and nondestructive evaluation of human meniscus functional integrity and health in real time during arthroscopic surgery.

  5. Gross anatomical study on the human myocardial bridges with special reference to the spatial relationship among coronary arteries, cardiac veins, and autonomic nerves.

    Science.gov (United States)

    Watanabe, Yuko; Arakawa, Takamitsu; Kageyama, Ikuo; Aizawa, Yukio; Kumaki, Katsuji; Miki, Akinori; Terashima, Toshio

    2016-04-01

    Coronary arteries are frequently covered by cardiac muscles. This arrangement is termed a myocardial bridge. Previous studies have shown that myocardial bridges can cause myocardial ischemic diseases or cardiac arrhythmia, but the relevant pathogenic mechanisms remain unknown. We examined 60 hearts from Japanese cadavers macroscopically to clarify the spatial relationships among coronary arteries, cardiac veins and autonomic nerves. We found 86 myocardial bridges in 47 hearts from the 60 cadavers examined (78.3%). Next, we dissected out nine hearts with myocardial bridges in detail under the operating microscope. We found no additional branches of coronary arteries on the myocardial bridge surfaces. However, the cardiac veins, which usually accompany the coronary arteries, ran independently on the myocardial bridge surfaces in the same region. Cardiac autonomic nerves comprised two rami: one was associated with the coronary artery under the myocardial bridge and the other ran on the surface of the bridge. Such spatial relationships among the coronary arteries, cardiac veins and cardiac autonomic nerves at the myocardial bridges are quite similar to those in mouse embryo hearts. © 2015 Wiley Periodicals, Inc.

  6. The application of amplicon length heterogeneity PCR (LH-PCR) for monitoring the dynamics of soil microbial communities associated with cadaver decomposition.

    Science.gov (United States)

    Moreno, Lilliana I; Mills, DeEtta; Fetscher, Jill; John-Williams, Krista; Meadows-Jantz, Lee; McCord, Bruce

    2011-03-01

    The placement of cadavers in shallow, clandestine graves may alter the microbial and geochemical composition of the underlying and adjacent soils. Using amplicon length heterogeneity-PCR (LH-PCR) the microbial community changes in these soils can be assessed. In this investigation, nine different grave sites were examined over a period of 16weeks. The results indicated that measurable changes occurred in the soil bacterial community during the decomposition process. In this study, amplicons corresponding to anaerobic bacteria, not indigenous to the soil, were shown to produce differences between grave sites and control soils. Among the bacteria linked to these amplicons are those that are most often part of the commensal flora of the intestines, mouth and skin. In addition, over the 16week sampling interval, the level of indicator organisms (i.e., nitrogen fixing bacteria) dropped as the body decomposed and after four weeks of environmental exposure they began to increase again; thus differences in the abundance of nitrogen fixing bacteria were also found to contribute to the variation between controls and grave soils. These results were verified using primers that specifically targeted the nifH gene coding for nitrogenase reductase. LH-PCR provides a fast, robust and reproducible method to measure microbial changes in soil and could be used to determine potential cadaveric contact in a given area. The results obtained with this method could ultimately provide leads to investigators in criminal or missing person scenarios and allow for further analysis using human specific DNA assays to establish the identity of the buried body. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. [The taphonomic aspects of cadaverous changes in corpses, buried in the plastic foils].

    Science.gov (United States)

    Stuller, F; Straka, L; Macko, V; Krivos, D; Krajcovic, J; Novomeský, F

    2008-10-01

    The forensic expertise of the 6 human bodies, being murdered in organised crime activities, had been realised by the authors. All the cadavers were packed in plastic bags or plastic foils, then buried to the illegal graves, being prepared in advance. The detail overlook and autopsy of the bodies had disclosed, that due of almost airtight sealing of the cadavers in plastic materials, the postmortal cadaverous changes went on much slower and were manifested under a different picture, as seen in the human cadavers being buried in the standard wooden coffins. The authors point out the peculiarities of such a postmortal changes, with particular focusing on the estimation of postmortal period.

  8. Biomechanical evaluation of an integrated fixation cage during fatigue loading: a human cadaver study.

    Science.gov (United States)

    Palepu, Vivek; Peck, Jonathan H; Simon, David D; Helgeson, Melvin D; Nagaraja, Srinidhi

    2017-04-01

    OBJECTIVE Lumbar cages with integrated fixation screws offer a low-profile alternative to a standard cage with anterior supplemental fixation. However, the mechanical stability of integrated fixation cages (IFCs) compared with a cage with anterior plate fixation under fatigue loading has not been investigated. The purpose of this study was to compare the biomechanical stability of a screw-based IFC with a standard cage coupled with that of an anterior plate under fatigue loading. METHODS Eighteen functional spinal units were implanted with either a 4-screw IFC or an anterior plate and cage (AP+C) without integrated fixation. Flexibility testing was conducted in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) on intact spines, immediately after device implantation, and post-fatigue up to 20,000 cycles of FE loading. Stability parameters such as range of motion (ROM) and lax zone (LZ) for each loading mode were compared between the 2 constructs at multiple stages of testing. In addition, construct loosening was quantified by subtracting post-instrumentation ROM from post-fatigue ROM. RESULTS IFC and AP+C configurations exhibited similar stability (ROM and LZ) at every stage of testing in FE (p ≥ 0.33) and LB (p ≥ 0.23) motions. In AR, however, IFCs had decreased ROM compared with AP+C constructs at pre-fatigue (p = 0.07) and at all post-fatigue time points (p ≤ 0.05). LZ followed a trend similar to that of ROM in AR. ROM increased toward intact motion during fatigue cycling for AP+C and IFC implants. IFC specimens remained significantly (p < 0.01) more rigid than specimens in the intact condition during fatigue for each loading mode, whereas AP+C construct motion did not differ significantly (p ≥ 0.37) in FE and LB and was significantly greater (p < 0.01) in AR motion compared with intact specimens after fatigue. Weak to moderate correlations (R 2 ≤ 56%) were observed between T-scores and construct loosening, with lower T

  9. STUDIES ON HUMAN FALLOPIAN TUBAL EPITHELIUM IN DIFFERENT AGE GROUPS

    Directory of Open Access Journals (Sweden)

    Jayasri

    2016-02-01

    Full Text Available BACKGROUND AND AIMS The “fallopian tubes” (oviducts or uterine tubes are long paired flexuous reproductive organ which transports ova, spermatozoa, zygotes, the pre-implantation morulae and blastocyst. It has major role during reproductive period, but it remains as if vestigial organ before puberty and after menopause. Due to increasing rate of tubal block and infertility, oviducts and their structures gaining importance and have become a subject of research in present days particularly epithelium. The aim of the study is to ascertain any histological difference of tubal epithelium in different age groups and the research work could be utilized for investigation and management of infertility. MATERIALS AND METHODS Seven samples of each group i.e., prereproductive, reproductive & postmenopausal were collected from fresh unembalmed human cadavers received in the department of Anatomy, FAA Medical College, Barpeta, Assam. The slides were prepared using the standard laboratory procedure. Under low and high power objectives the type of cells were observed and epithelial height was measured in the different segments. Stress was given for any significant difference of epithelial height between the different age groups. RESULTS Study revealed that among the groups within the same segment, epithelial height was recorded highest (33.57µm in reproductive group as against the lowest (22.91µm in post-menopausal group. Epithelial structures of the prereproductive and reproductive groups were significantly differed (p<0.01 from the postmenopausal group. CONCLUSIONS From the findings of the present study it can be concluded that: 1. In all the groups fallopian tubal epithelium is of simple columnar type and contains three types of cells. Cells are ciliated, secretory & peg (intercalary cells. 2. In all the groups same type of increasing trend of epithelial height from intramural segment to ampullary segment was recorded. 3. In intergroup comparison of

  10. Tendons in the plantar aspect of the foot: MR imaging and anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Rodrigo [University of California San Diego, Radiology, San Diego, CA (United States); Fleury Medical Center, Radiology, Sao Paulo, SP (Brazil); Aguiar, Rodrigo; Trudell, Debra; Resnick, Donald [University of California San Diego, Radiology, San Diego, CA (United States)

    2007-02-15

    The purpose of this anatomic imaging study was to illustrate the normal complex anatomy of tendons of the plantar aspect of the ankle and foot using magnetic resonance (MR) imaging with anatomic correlation in cadavers. Seven fresh cadaveric feet (obtained and used according to institutional guidelines, with informed consent from relatives of the deceased) were studied with intermediate-weighted fast-spin-echo MR imaging. For anatomic analysis, cadaveric specimens were sectioned in 3-mm-thick slices in the coronal and axial planes that approximated the sections acquired at MR imaging. The entire courses of the tendons into the plantar aspect of the foot were analyzed. The tibialis posterior tendon has a complex distal insertion. The insertions in the navicular, second, and third cuneiforms bones were identify in all cases using axial and coronal planes. A tendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons was identified in five of our specimens (71%). The coronal plane provided the best evaluation. The peroneus longus tendon changes its direction at three points then obliquely crosses the sole and inserts in the base of the first metatarsal bone and the plantar aspect of the first cuneiform. MR imaging provides detailed information about the anatomy of tendons in the plantar aspect of the ankle and foot. It allows analysis of their insertions and the intertendinous connection between the flexor hallucis longus and the flexor digitorum longus tendons. (orig.)

  11. Effects of Er:YAG laser irradiation on human cartilage

    Science.gov (United States)

    Glinkowski, Wojciech; Brzozowska, Malgorzata; Ciszek, Bogdan; Rowinski, Jan; Strek, Wieslaw

    1996-03-01

    Irradiation of the hyaline or fibrous cartilage excised from the body of a human cadaver with Er:YAG laser beam, single pulse with a dose of 1 J, produces a crater with a depth of approximately 500 micrometers and a diameter varying from 5 to 300 micrometers. Histological examination has revealed that the laser-made craters were surrounded by a thin rim (2-10 micrometer) of charred and coagulated tissue. No damage was observed in the cartilage surrounding the rim. The presence of sharp demarcation between the tissue areas ablated by laser energy and the undamaged areas argues for the potential usefulness of the Er:YAG laser in surgery of cartilages.

  12. Nasal Unit Transplantation: A Cadaveric Anatomical Feasibility Study.

    Science.gov (United States)

    Dorafshar, Amir H; Mundinger, Gerhard S; Robinson, Brent; Tuffaha, Sami; Brandacher, Gerald; Byrne, Patrick; Walton, Robert L

    2017-05-01

    Background  The science and technical acumen in the field of vascularized composite allotransplantation has progressed rapidly over the past 15 years, and transplantation of specialized units of the face, such as the nose, appears possible. No study to date has evaluated the technical feasibility of isolated nasal unit transplantation (NUT). In this study, we explore the anatomy and technical specifics of NUT. Methods  In this study, four fresh cadaver heads were studied. Bilateral vascular pedicle dissections were performed in each cadaver. The facial artery was cannulated and injected with food dye under physiologic pressure in two cadavers, and with lead oxide mixture in two cadavers to evaluate perfusion territories supplied by each vascular pedicle. Results  The facial artery and vein were found to be adequate pedicles for NUT. Divergent courses of the vein and artery were consistently identified, which made for a bulky pedicle with necessary inclusion of large amounts of subcutaneous tissue. In all cases, the artery remained superficial, while the vein coursed in a deeper plane, and demonstrated consistent anastomoses with the superior transverse orbital arcade. While zinc oxide injection of the facial artery demonstrated filling of the nasal vasculature across the midline, dye perfusion studies suggested that unilateral arterial inflow may be insufficient to perfuse contralateral NUT components. Discrepancies in these two studies underscore the limitations of nondynamic assessment of nutritive perfusion. Conclusion  NUT based on the facial artery and facial vein is technically feasible. Angiosome evaluation suggests that bilateral pedicle anastomoses may be required to ensure optimal perfusion. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. Cadaver wrapping and arrival performance of adult flies in an oil palm plantation in northern Peninsular Malaysia.

    Science.gov (United States)

    Ahmad, Azwani; Ahmad, Abu Hassan; Dieng, Hamady; Satho, Tomomitsu; Ahmad, Hamdan; Aziz, Al Thbyani; Boots, Michael

    2011-11-01

    There is accumulating evidence that criminals wrap dead bodies in an attempt to conceal evidence. To anticipate the forensic implications of this phenomenon, we examined whether flies that are naturally associated with cadavers exhibit a delay in attendance or differ in species composition and abundance patterns because of the presence of wrapping material. Wrapped and exposed carcasses of dead monkeys placed in an oil plantation in Kedah, Malaysia, were visited over 50 d. On daily visits to each of the six carcasses, visiting adult flies were sampled using hand nets. Flies of 12 families were encountered. Calliphoridae (Chrysomya rufifacies Macquart and C. megacephala (F.) was the most prevalent family, followed by Sphaeroceridae. Some families tended to be more abundant in WRCs (i.e., Calliphoridae, Muscidae, and Phoridae), whereas others (i.e., Piophilidae, Sepsidae, and Psychodidae) were more prevalent in exposed carcasses. Wrapping delayed the arrival of all fly species encountered, with delays varying from 1 to 13 d depending on species. Wrapping did not affect species composition of flies, but prolong the occurrence of some species. The results of the current study emphasize the need to take into consideration the presence of a wrap when estimating postmortem interval.

  14. Variability in anatomical features of human clavicle: Its forensic anthropological and clinical significance

    Directory of Open Access Journals (Sweden)

    Jagmahender Singh Sehrawat

    2016-06-01

    Full Text Available Bones can reflect the basic framework of human body and may provide valuable information about the biological identity of the deceased. They, often, survive the morphological alterations, taphonomic destructions, decay/mutilation and decomposition insults. In-depth knowledge of variations in clavicular shape, size and its dimensions is very important from both clinical (fixation of clavicular fractures using external or inter-medullary devices, designing orthopedic fixation devices as well as forensic anthropological perspectives. Human clavicle is the most frequently fractured bone of human skeleton, possessing high degree of variability in its anatomical, biomechanical and morphological features. Extended period of skeletal growth (up to third decade in clavicle imparts it an additional advantage for forensic identification purposes. In present study, five categories of clavicular features like lengths, diameters, angles, indices and robustness were examined to explore the suitability of collarbone for forensic and clinical purposes. For this purpose, 263 pairs of adult clavicles (195 Males and 68 Females were collected from autopsied cadavers and were studied for 13 anatomical features. Gender and occupational affiliations of cadavers were found to have significant influences on anatomical dimensions of their clavicles. Product index, weight and circumference of collarbone were found the best univariate variables, discriminating sex of more than 80% individuals. The best multivariate Function-I (DF: -17.315 + 0.054 CL-L+0.196 CC-R+0.184 DM-L could identify sex and occupation of 89.4% (89.2% Male and 89.7% Female and 65.4% individuals, respectively. All clavicular variables were found bilaterally asymmetric; left clavicles being significantly longer in length, lighter in weight, smooth in texture and less curved than the right side bones. Among non-metric traits, sub-clavian groove, nutrient foramina and ‘type’ of clavicle exhibited

  15. Sulfated glycosaminoglycans in human vocal fold lamina propria

    Directory of Open Access Journals (Sweden)

    Sung Woo Park

    Full Text Available Abstract Introduction: The distribution, concentration and function of glycosaminoglycans in the various vocal fold tissues are still unclear. Objective: To evaluate the distribution and concentration of sulfated glycosaminoglycans in different layers of the human vocal fold according to gender and age. Methods: We used 11 vocal folds obtained from cadavers (7 men and 4 women with no laryngeal lesion, less than 12 h after death, and aged between 35 and 98 years. The folds underwent glycosaminoglycans extraction from the cover and ligament, and post-electrophoresis analysis. Data were compared according to the layer, age and gender. Results: The concentration of dermatan sulfate was significantly higher in all layers. No differences were observed in the total concentrations of glycosaminoglycans in layers studied according to gender. It is significantly lower in the cover of individuals aged below 60 years. Conclusion: Dermatan sulfate, chondroitin sulfate, and heparan sulfate were observed in the human vocal folds cover and ligament of both genders, with the concentration of dermatan sulfate being significantly higher in all layers. Glycosaminoglycans concentration on the cover is significantly lower in individuals below 60 years compared with elderly.

  16. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  17. The histopathologic reliability of tissue taken from cadavers within the gross anatomy laboratory.

    Science.gov (United States)

    Rae, Guenevere; Newman, William P; McGoey, Robin; Donthamsetty, Supriya; Karpinski, Aryn C; Green, Jeffrey

    2018-03-01

    The purpose of this study was to examine the histopathologic reliability of embalmed cadaveric tissue taken from the gross anatomy laboratory. Tissue samples from hearts, livers, lungs, and kidneys were collected after the medical students' dissection course was completed. All of the cadavers were embalmed in a formalin-based fixative solution. The tissue was processed, embedded in paraffin, sectioned at six micrometers, and stained with H&E. The microscope slides were evaluated by a board certified pathologist to determine whether the cellular components of the tissues were preserved at a high enough quality to allow for histopathologic diagnosis. There was a statistically significant relationship between ratings and organ groups. Across all organs, there was a smaller proportion of "poor" ratings. The lung group had the highest percentage of "poor" ratings (23.1%). The heart group had the least "poor" ratings (0.0%). The largest percentage of "satisfactory" ratings were in the lung group (52.8%), and the heart group contained the highest percentage of "good" ratings (58.5%) The lung group had the lowest percentage of "good" ratings (24.2%). These results indicate that heart tissue is more reliable than lung, kidney, or liver tissue when utilizing tissue from the gross anatomy laboratory for research and/or educational purposes. This information advises educators and researchers about the quality and histopathologic reliability of tissue samples obtained from the gross anatomy laboratory. Anat Sci Educ 11: 207-214. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  18. Device-length changes and implant function following surgical implantation of the KineSpring in cadaver knees

    Directory of Open Access Journals (Sweden)

    McNicholas MJ

    2015-01-01

    Full Text Available Michael J McNicholas,1 Stefan M Gabriel,2 Anton G Clifford,2 Evelyne M Hasler2 1Aintree University Hospital, Teaching Hospital, Major Trauma Centre, NHS Foundation Trust, Liverpool, UK; 2Moximed, Hayward, CA, USA Introduction: The KineSpring implant system has been shown to provide load reductions at the medial compartment of the knee, and has demonstrated clinical success in reducing pain and increasing function in patients with medial knee osteoarthritis. These results depend on the ability of the KineSpring to rotate, lengthen, and shorten to accommodate knee motions, and in response to knee position and loading. Purpose: The present study was undertaken to determine length changes of the implanted KineSpring in response to a range of knee positions, external knee loads, and placements by different orthopedic surgeons. Materials and methods: KineSpring system components were implanted in ten cadaver leg specimens by ten orthopedic surgeons, and absorber-length changes were measured under combined loading and in different positions of the knee. Results and conclusion: Spring compression consistent with knee-load reduction, and device lengthening and shortening to accommodate knee loads and motions were seen. These confirm the functionality of the KineSpring when implanted medially to the knee. Keywords: KineSpring, knee, function, preservation, offloading, osteoarthritis

  19. Evaluation of Potential Infectivity of Alzheimer and Parkinson Disease Proteins in Recipients of Cadaver-Derived Human Growth Hormone

    Science.gov (United States)

    Irwin, David J.; Abrams, Joseph Y.; Schonberger, Lawrence B.; Leschek, Ellen Werber; Mills, James L.; Lee, Virginia M.-Y.; Trojanowski, John Q.

    2013-01-01

    Importance Growing evidence of cell-to-cell transmission of neurodegenerative disease (ND)–associated proteins (NDAPs) (ie, tau, Aβ, and α-synuclein) suggests possible similarities in the infectious prion protein (PrPsc) in spongiform encephalopathies. There are limited data on the potential human-to-human transmission of NDAPs associated with Alzheimer disease (AD) and other non-PrPsc ND. Objective To examine evidence for human-to-human transmission of AD, Parkinson disease (PD), and related NDAPs in cadaveric human growth hormone (c-hGH) recipients. Design We conducted a detailed immunohistochemical analysis of pathological NDAPs other than PrPsc in human pituitary glands. We also searched for ND in recipients of pituitary-derived c-hGH by reviewing the National Hormone and Pituitary Program (NHPP) cohort database and medical literature. Setting University-based academic center and agencies of the US Department of Health and Human Services. Participants Thirty-four routine autopsy subjects (10 non-ND controls and 24 patients with ND) and a US cohort of c-hGH recipients in the NHPP. Main Outcome Measures Detectable NDAPs in human pituitary sections and death certificate reports of non-PrPsc ND in the NHPP database. Results We found mild amounts of pathological tau, Aβ, and α-synuclein deposits in the adeno/neurohypophysis of patients with ND and control patients. No cases of AD or PD were identified, and 3 deaths attributed to amyotrophic lateral sclerosis (ALS) were found among US NHPP c-hGH recipients, including 2 of the 796 decedents in the originally confirmed NHPP c-hGH cohort database. Conclusions and Relevance Despite the likely frequent exposure of c-hGH recipients to NDAPs, and their markedly elevated risk of PrPsc-related disease, this population of NHPP c-hGH recipients does not appear to be at increased risk of AD or PD. We discovered 3 ALS cases of unclear significance among US c-hGH recipients despite the absence of pathological deposits of ALS

  20. Voluntary Body Donation: The Gift that Lives on Forever

    Science.gov (United States)

    Saritha, S.; Rao, M. Vittoo; Sumangala; Supriya, G.; Kumar, Praveen

    2012-10-01

    Body donation is a gracious act, Shankarcharaya firmly believed in concept of Body Donation or Organ Donation and said Iddham sharirum paropakarum i.e. the body is for use of others and death is not the end, it is the beginning. Anatomy is important basic subject for medicalstudents, both U.G. & P.G. Best method of Anatomy learning is by dissection on human cadavers, which remains principle teaching tool. Human cadavers for purpose of study are a scarcity with mushrooming of medical institutions in this country. Unclaimed bodies are no more origin of cadavers. Whole Body donation is the need of the hour. A Voluntary Body Donation is defined as the act of giving oneís Body after death for Medical research and education. In this article a survey was done in S.V.S. Medical & Dental Colleges Faculty members and medical exhibition visitors which include lawyers, engineers, teachers and others during the year of 2010. The body donation including organ donation and various factors such as age, religion, culture and donorís attitude are discussed. Body donation provides the students and medical researchers with unparalleled opportunities to study the human body. Computers nor books cannot totally replace body dissection in learning the anatomy.

  1. Human corneal endothelial cell transplantation using nanocomposite gel sheet in bullous keratopathy.

    Science.gov (United States)

    Parikumar, Periasamy; Haraguchi, Kazutoshi; Senthilkumar, Rajappa; Abraham, Samuel Jk

    2018-01-01

    Transplantation of in vitro expanded human corneal endothelial precursors (HCEP) cells using a nanocomposite (D25-NC) gel sheet as supporting material in bovine's cornea has been earlier reported. Herein we report the transplantation of HCEP cells derived from a cadaver donor cornea to three patients using the NC gel sheet. In three patients with bullous keratopathy, one after cataract surgery, one after trauma and another in the corneal graft, earlier performed for congenital corneal dystrophy, not amenable to medical management HCEP cells isolated from a human cadaver donor cornea in vitro expanded using a thermoreversible gelation polymer (TGP) for 26 days were divided into three equal portions and 1.6 × 10 5 HCEP cells were injected on to the endothelium of the affected eye in each patient using the D25-NC gel sheet as a supporting material. The sheets were removed after three days. The bullae in the cornea disappeared by the 3 rd -11 th post-operative day in all the three patients. Visual acuity improved from Perception of light (PL)+/Projection of rays (PR)+ to Hand movements (HM)+ in one of the patients by post-operative day 3 which was maintained at 18 months follow-up. At 18 months follow-up, in another patient the visual acuity had improved from HM+ to 6/60 while in the third patient, visual acuity remained HM+ as it was prior to HCEP transplantation. There were no adverse effects during the follow-up in any of the patients.

  2. Anatomical study of terminal peroneal artery perforators and their clinical applications

    Directory of Open Access Journals (Sweden)

    Rajendran Purushothaman

    2013-01-01

    Full Text Available Introduction: Peroneal artery gives off plenty of perforators that pass through fascial septum to supply skin and tenosynovium of peroneal muscles. Aim: The aim of this study was to study the anatomical basis of perforators from terminal part of peroneal artery axiality and to make use of this knowledge in reconstructing defects of posterior heel with the advantage of reducing the morbidity of conventional flaps. Materials and Methods: Our study was conducted at Department of Plastic surgery, Madras Medical College and Rajiv Gandhi Government General Hospital, India. We have carried out eleven cadaver dissections (from six cadavers-four fresh cadavers and two preserved cadavers and delineated all septocutaneous and septosynovial perforators of distal peroneal axis and studied their relation with short saphenous vein (SSV and sural nerve. Using this anatomical knowledge we have fashioned perforator based flaps in 13 patients (three propeller, four V-Y advancement, six tenosynovial flaps for reconstruction of defects over tendo achilles and pericalcaneal region . Results: In all cases, SSV and sural nerve were preserved and donor site was closed primarily. No total flap loss was noted. Conclusion: Perforator based flaps from distal most part of peroneal artery provide a good and reliable method for reconstruction of pericalcaneal and tendo achilles region defects with preservation of SSV and sural nerve. It also avoids contour deformity of the grafted donor site of the classical lateral calcaneal artery axial flap.

  3. An aetiological study on spondylolysis from a biomechanical aspect.

    Science.gov (United States)

    Ichikawa, N.; Ohara, Y.; Morishita, T.; Taniguichi, Y.; Koshikawa, A.; Matsukura, N.

    1982-01-01

    The authors report clinical studies on lumbar disorders (clinical symptoms, X-ray findings) in athletes in various sports. The sport items were divided into three groups according to the main dynamic load applied to the lumbar region. As a result, over 60% of the athletes suffered from "lumbago", and among them spondylolysis reached the high rate of 27%. Arising from these clinical observations, we performed biomechanical laboratory analyses on human cadaver material, axial compression and rotational bending. Our results suggest that the incidence of spondylolysis depends upon the extent and direction of the loads. Images Fig. 4 Fig. 5 Fig. 8 Fig. 9 Fig. 10 PMID:7139222

  4. Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabula.

    Science.gov (United States)

    Müller, L P; Degreif, J; Rudig, L; Mehler, D; Hely, H; Rommens, P M

    2004-12-01

    Studies of hip arthroplasty have dealt mainly with total endoprosthesis, while tribology measurement values of hemi-endoprosthetic implants are rare. The small amount of experimental tribological data concerning materials of hemi-endoprosthetic implants in the form of pendulum trials, animal experiments, in vivo measurements on human hip joints and pin on disc studies report friction coefficients between 0.014 and 0.57; the friction coefficients measured in fresh human cadaver hip joints were determined between 0.001 and 0.08. The HEPFlEx-hip simulator was constructed to test the friction coefficients of unipolar femur head hemi-endoprostheses made of metal or ceramic against fresh cadaveric acetabula. Its plane of movement is uniaxial with a flexion-extension movement of +30/-18 degrees . The force is produced pneumatically dynamic with amounts of 2.5 kN. Newborn calf serum serves as a lubricant. We mounted 20 fresh porcine acetabula and 10 fresh human cadaver acetabula in the HEPFlEx-hip simulator and compared the two unipolar femur head hemi-endoprostheses (metal vs. ceramic). The mean friction coefficients against porcine acetabula were micro=0.017-0.082 for ceramic and micro=0.020-0.101 for metal; against human cadaver acetabula micro=0.017-0.083 for ceramic and micro=0.019-0.118 for metal. The frictional coefficient deltas (metal-ceramic) values of all measurements were Deltamicro=0.004 for porcine acetabula and Deltamicro=0.001 for cadaver acetabula. Box-plots graphics document significantly lower frictional coefficients of the ceramics. The lower frictional coefficients of ceramic compared to metal against fresh cadaveric acetabula may have a clinical impact on the process of the protrusion of the corresponding femoral head through the acetabulum.

  5. Biomechanical Comparison of Standard and Linked Single-Row Rotator Cuff Repairs in a Human Cadaver Model.

    Science.gov (United States)

    Meisel, Adam F; Henninger, Heath B; Barber, F Alan; Getelman, Mark H

    2017-05-01

    The purpose of this study was to evaluate the time zero cyclic and failure loading properties of a linked single-row rotator cuff repair compared with a standard simple suture single-row repair using triple-loaded suture anchors. Eighteen human cadaveric shoulders from 9 matched pairs were dissected, and full-thickness supraspinatus tears were created. The tendon cross-sectional area was recorded. In each pair, one side was repaired with a linked single-row construct and the other with a simple suture single-row construct, both using 2 triple-loaded suture anchors. After preloading, specimens were cycled to 1 MPa of effective stress at 1 Hz for 500 cycles, and gap formation was recorded with a digital video system. Samples were then loaded to failure, and modes of failure were recorded. There was no statistical difference in peak gap formation between the control and linked constructs (3.6 ± 0.9 mm and 3.6 ± 1.2 mm, respectively; P = .697). Both constructs averaged below a 5-mm cyclic failure threshold. There was no statistical difference in ultimate load to failure between the control and linked repair (511.1 ± 139.0 N and 561.2 ± 131.8 N, respectively; P = .164), and both groups reached failure at loads similar to previous studies. Constructs failed predominantly via tissue tearing parallel to the medial suture line. The linked repair performed similarly to the simple single-row repair. Both constructs demonstrated high ultimate load to failure and good resistance to gap formation with cyclic loading, validating the time zero strength of both constructs in a human cadaveric model. The linked repair provided equivalent resistance to gap formation and failure loads compared with simple suture single-row repairs with triple-loaded suture anchors. This suggests that the linked repair is a simplified rip-stop configuration using the existing suture that may perform similarly to current rotator cuff repair techniques. Copyright © 2016 Arthroscopy

  6. Increased signal intensity at the proximal patellar tendon: correlation between MR imaging and histology in eight cadavers and clinical MR imaging studies

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Seong Jong; Jin, Wook; Yoon, So Hee; Park, So Young [Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Yong-Koo [Kyung Hee University Medical Center, Department of Pathology, Seoul (Korea, Republic of); Kim, Gou Young [Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Department of Pathology, Seoul (Korea, Republic of); Lee, Jung Eun; Park, Ji Seon; Ryu, Kyung Nam [Kyung Hee University Medical Center, Department of Radiology, Seoul (Korea, Republic of)

    2015-10-15

    We set out to investigate the cause of persistently increased signal intensity (SI) in the posterior portion of the proximal patellar tendon (pPT) on T1-weighted images (T1WI). MR imaging was performed in eight cadavers, followed by gross histological examination. In addition, 84 patients without trauma history or anterior knee pain were included to compare the SI of the PTs. The patients were divided according to their age, sex, and Kellgren-Lawrence (KL) grades. The length and thickness of the increased SI portion in the pPT and whole PT (wPT) on T1WI were recorded. Histological specimens demonstrated that the adipose tissue, vessels, and perivascular connective tissue invaginated into the posterior portion of the pPT. This histological anatomy corresponded to the pPT signal change on MR imaging. There was linear and interdigitating increased SI of the pPT in all of the 84 patients (100 %). There were no differences in the lengths and thicknesses of the increased SI portion of pPTs and wPTs according to age, sex, and KL grade (all p > 0.05). The increased SI of the pPT on T1WI and fluid-sensitive MR images results from invaginating fat, vessels, and perivascular connective tissue. It is not pathological, but a normal and common finding. (orig.)

  7. Blow fly maggots (Diptera: Calliphoridae)from a human corpse in a vehicle.

    Science.gov (United States)

    Sribanditmongkol, Pongruk; Monum, Tawachai; Wannasan, Anchalee; Tomberlin, Jeffery K; Sukontason, Kom; Sukontason, Kabkaew L

    2014-09-01

    Correct species identification and development data of insects associated with a cadaver can help estimate the time of colonization which could be used to infer a minimal post-mortem interval (minPMI) for forensic investigations. Human remains are found in a variety of locations ranging from open fields to inside automobiles. We report the investigation of blow fly larvae collected from a decomposing body located in the trunk of a car. There were two blow fly (Diptera: Calliphoridae) species: Achoetandrus rufifacies (Macquart) and Chrysomya megacephala (Fabricius). Blow flies can enter the vehicle and colonize human remains. Based on age estimations of third stage larvae of A. rufifacies, the minPMI was estimated to be 4-5 days, which was within the range of 3-5 days estimated by other forensically relevant information.

  8. Quantitative and qualitative analysis of cadaveric human pinealocytes in various age groups

    International Nuclear Information System (INIS)

    Rabia, A.

    2011-01-01

    Objective: To determine age-related quantitative and qualitative changes in human pinealocytes using cadaveric material. Study Design: Analytical cross-sectional study. Place and Duration of Study: The study was conducted in the Department of Anatomy, University of Health Sciences, Lahore, from January to December 2008. Methodology: Thirty pineal glands from human cadavers ranging from 16-80 years of age were collected from mortuary of King Edward Medical University, Lahore, using purposive non-probability sampling. These were divided into three different age groups: I, II and III each between 16 to 30, 31 to 45 and 46 to 80 years of age respectively. Pinealocytes were counted; their mean diameter and that of their nuclei was calculated from a total of 30 cells per slide, using 4 macro m thick H and E stained histological sections. Mean +- S.E.M. was calculated for quantitative variables. One-way ANOVA was applied to observe group mean differences among three groups. Results: The number of pinealocytes decreased with aging but the difference was statistically insignificant when compared between groups (p=0.234). There was no change in size of pinealocyte soma and its nucleus (p=0.889 and 0.898 respectively). Conclusion: The number and size of pinealocytes, and their nuclei remained unaltered with advancing age. (author)

  9. Willingness toward Organ and Body Donation among Anatomy Professors and Students in Mexico

    Science.gov (United States)

    Quiroga-Garza, Alejandro; Reyes-Hernández, Cynthia Guadalupe; Zarate-Garza, Pablo Patricio; Esparza-Hernández, Claudia Nallely; Gutierrez-de la O, Jorge; de la Fuente-Villarreal, David; Elizondo-Omaña, Rodrigo Enrique; Guzman-Lopez, Santos

    2017-01-01

    Most anatomists agree that cadaver dissection serves as a superior teaching tool in human anatomy education. However, attitudes toward body donation vary widely between different individuals. A questionnaire was developed to determine the attitudes toward body and organ donation among those who learn the most from cadavers: medical students,…

  10. Optimal training for emergency needle thoracostomy placement by prehospital personnel: didactic teaching versus a cadaver-based training program.

    Science.gov (United States)

    Grabo, Daniel; Inaba, Kenji; Hammer, Peter; Karamanos, Efstathios; Skiada, Dimitra; Martin, Matthew; Sullivan, Maura; Demetriades, Demetrios

    2014-09-01

    Tension pneumothorax can rapidly progress to cardiac arrest and death if not promptly recognized and appropriately treated. We sought to evaluate the effectiveness of traditional didactic slide-based lectures (SBLs) as compared with fresh tissue cadaver-based training (CBT) for placement of needle thoracostomy (NT). Forty randomly selected US Navy corpsmen were recruited to participate from incoming classes of the Navy Trauma Training Center at the LAC + USC Medical Center and were then randomized to one of two NT teaching methods. The following outcomes were compared between the two study arms: (1) time required to perform the procedure, (2) correct placement of the needle, and (3) magnitude of deviation from the correct position. During the study period, a total of 40 corpsmen were enrolled, 20 randomized to SBL and 20 to CBT arms. When outcomes were analyzed, time required to NT placement was not different between the two arms. Examination of the location of needle placement revealed marked differences between the two study groups. Only a minority of the SBL group (35%) placed the NT correctly in the second intercostal space. In comparison, the majority of corpsmen assigned to the CBT group demonstrated accurate placement in the second intercostal space (75%). In a CBT module, US Navy corpsmen were better trained to place NT accurately than their traditional didactic SBL counterparts. Further studies are indicated to identify the optimal components of effective simulation training for NT and other emergent interventions.

  11. Earliest directly-dated human skull-cups.

    Directory of Open Access Journals (Sweden)

    Silvia M Bello

    Full Text Available BACKGROUND: The use of human braincases as drinking cups and containers has extensive historic and ethnographic documentation, but archaeological examples are extremely rare. In the Upper Palaeolithic of western Europe, cut-marked and broken human bones are widespread in the Magdalenian (∼15 to 12,000 years BP and skull-cup preparation is an element of this tradition. PRINCIPAL FINDINGS: Here we describe the post-mortem processing of human heads at the Upper Palaeolithic site of Gough's Cave (Somerset, England and identify a range of modifications associated with the production of skull-cups. New analyses of human remains from Gough's Cave demonstrate the skilled post-mortem manipulation of human bodies. Results of the research suggest the processing of cadavers for the consumption of body tissues (bone marrow, accompanied by meticulous shaping of cranial vaults. The distribution of cut-marks and percussion features indicates that the skulls were scrupulously 'cleaned' of any soft tissues, and subsequently modified by controlled removal of the facial region and breakage of the cranial base along a sub-horizontal plane. The vaults were also 'retouched', possibly to make the broken edges more regular. This manipulation suggests the shaping of skulls to produce skull-cups. CONCLUSIONS: Three skull-cups have been identified amongst the human bones from Gough's Cave. New ultrafiltered radiocarbon determinations provide direct dates of about 14,700 cal BP, making these the oldest directly dated skull-cups and the only examples known from the British Isles.

  12. Optical spectroscopic determination of human meniscus composition.

    Science.gov (United States)

    Ala-Myllymäki, Juho; Honkanen, Juuso T J; Töyräs, Juha; Afara, Isaac O

    2016-02-01

    This study investigates the correlation between the composition of human meniscus and its absorption spectrum in the visible (VIS) and near infrared (NIR) spectral range. Meniscus samples (n = 24) were obtained from nonarthritic knees of human cadavers with no history of joint diseases. Specimens (n = 72) were obtained from three distinct sections of the meniscus, namely; anterior, center, posterior. Absorption spectra were acquired from each specimen in the VIS and NIR spectral range (400-1,100 nm). Following spectroscopic probing, the specimens were subjected to biochemical analyses to determine the matrix composition, that is water, hydroxyproline, and uronic acid contents. Multivariate analytical techniques, including principal component analysis (PCA) and partial least squares (PLS) regression, were then used to investigate the correlation between the matrix composition and it spectral response. Our results indicate that the optical absorption of meniscus matrix is related to its composition, and this relationship is optimal in the NIR spectral range (750-1,100 nm). High correlations (R(2) (uronic)  = 86.9%, R(2) (water)  = 83.8%, R(2) (hydroxyproline)  = 81.7%, p meniscus composition, thus suggesting that spectral data in the NIR range can be utilized for estimating the matrix composition of human meniscus. In conclusion, optical spectroscopy, particularly in the NIR spectral range, is a potential method for evaluating the composition of human meniscus. This presents a promising technique for rapid and nondestructive evaluation of meniscus integrity in real-time during arthroscopic surgery. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  13. A probabilistic model of human variability in physiology for future application to dose reconstruction and QIVIVE.

    Science.gov (United States)

    McNally, Kevin; Loizou, George D

    2015-01-01

    The risk assessment of environmental chemicals and drugs is undergoing a paradigm shift in approach which seeks the full replacement of animal testing with high throughput, mechanistic, in vitro systems. This new approach will be reliant on the measurement in vitro, of concentration-dependent responses where prolonged excessive perturbations of specific biochemical pathways are likely to lead to adverse health effects in an intact organism. Such an approach requires a framework, into which disparate data generated by in vitro, in silico, and in chemico systems can be integrated and utilized for quantitative in vitro-to-in vivo extrapolation (QIVIVE), ultimately to the human population level. Physiologically based pharmacokinetic (PBPK) models are ideally suited to this and are needed to translate in vitro concentration- response relationships to an exposure or dose, route and duration regime in human populations. Thus, a realistic description of the variation in the physiology of the human population being modeled is critical. Whilst various studies in the past decade have made progress in describing human variability, the algorithms are typically coded in computer programs and as such are unsuitable for reverse dosimetry. In this report we overcome this limitation by developing a hierarchical statistical model using standard probability distributions for the specification of a virtual US and UK human population. The work draws on information from both population databases and cadaver studies.

  14. A probabilistic model of human variability in physiology for future application to dose reconstruction and QIVIVE

    Directory of Open Access Journals (Sweden)

    Kevin eMcNally

    2015-10-01

    Full Text Available The risk assessment of environmental chemicals and drugs is undergoing a paradigm shift in approach which seeks the full replacement of animal testing with high throughput, mechanistic, in vitro systems. This new approach will be reliant on the measurement in vitro, of concentration-dependent responses where prolonged excessive perturbations of specific biochemical pathways are likely to lead to adverse health effects in an intact organism. Such an approach requires a framework, into which disparate data generated by in vitro, in silico and in chemico systems can be integrated and utilised for quantitative in vitro-to-in vivo extrapolation (QIVIVE, ultimately to the human population level. Physiologically based pharmacokinetic (PBPK models are ideally suited to this and are needed to translate in vitro concentration- response relationships to an exposure or dose, route and duration regime in human populations. Thus a realistic description of the variation in the physiology of the human population being modelled is critical. Whilst various studies in the past decade have made progress in describing human variability, the algorithms are typically coded in computer programs and as such are unsuitable for reverse dosimetry. In this report we overcome this limitation by developing a hierarchical statistical model using standard probability distributions for the specification of a virtual US and UK human population. The work draws on information from both population databases and cadaver studies.

  15. Estudo anatômico do ligamento patelofemoral lateral em joelho de cadáveres Anatomical study of the lateral patellofemoral ligament in cadaver knees

    Directory of Open Access Journals (Sweden)

    Marcelo Schmidt Navarro

    2008-07-01

    Full Text Available OBJETIVOS: Descrever o ligamento patelofemoral lateral (LPFL por meio de dissecação anatômica de joelhos de cadáveres frescos. Na literatura existe particular interesse pelo LPFL. Essa especial atenção é dada pela sua importância anatômica, biomecânica e pela necessidade da sua reconstrução nos casos de instabilidade medial da patela. MÉTODOS: O LPFL foi estudado em 20 joelhos de 20 cadáveres frescos por meio de dissecações anatômicas. As dissecações foram padronizadas e os dados anotados enviados para análise estatística. RESULTADOS: O LPFL apresentou em média 16,05mm de largura (desvio-padrão: 2,48, 42,10mm de comprimento (desvio-padrão: 8,84. Sua inserção femoral mostrou-se no epicôndilo femoral lateral e com expansão em forma de leque das suas fibras, predominantemente na região posterior e proximal ao epicôndilo lateral. Na patela a inserção encontrada foi na região súpero-lateral (na metade do terço superior no plano coronal, também com expansão das fibras, mas com menor intensidade. No plano sagital, o ligamento situava-se na metade posterior da borda da patela. O LPFL foi isolado na segunda camada retinacular lateral, o retináculo transverso profundo. CONCLUSÃO: O LPFL situa-se na camada retinacular transversa profunda, com a presença de uma expansão das suas fibras em forma de leque, tanto na inserção femoral quanto na patelar. No epicôndilo femoral a inserção encontra-se mais posterior e proximalmente e na patela está na metade posterior da borda patelar (plano sagital e no aspecto súpero-lateral.OBJECTIVES: To describe the lateral patellofemoral ligament (LPFL after anatomical dissection of fresh cadaver knees. The literature shows a particular interest for the LPFL. Such special attention is due to its anatomical and biomechanical importance, and also due to the need to reconstruct the ligament in the cases of medial patellar instability. METHODS: The LPFL was studied in 20 knees of 20

  16. Merkel cell distribution in the human eyelid

    Directory of Open Access Journals (Sweden)

    C.A. May

    2013-10-01

    Full Text Available Although Merkel cell carcinoma of the eye lid is reported frequently in the literature, only limited information exists about the distribution of Merkel cells in this tissue. Therefore, serial sections of 18 human cadaver eye lids (donors ages ranging between 63 and 97 years were stained for cytokeratin 20 in various planes. The overall appearance of Merkel cells in these samples was low and mainly located in the outer root layer of the cilia hair follicles. Merkel cells were more frequent in the middle, and almost not detectable at the nasal and temporal edges. The localization is in accordance with that of Merkel cell carcinoma, but concerning the scarce appearance within this adulthood group, a specific physiological role of these cells in the eye lid is difficult to establish.

  17. Patterns of oviposition and development of Chrysomya megacephala (Fabricius) (Diptera: Calliphoridae) and Chrysomya rufifacies (Macquart) (Diptera: Calliphoridae) on burned rabbit carcasses.

    Science.gov (United States)

    Mahat, N A; Zainol-Abidin, N L; Nordin, N H; Abdul-Wahab, R; Jayaprakash, P T

    2016-03-01

    Considering that crimes against animals such as illegal killing and cruelty have been alarmingly increasing and since burning is one of the common ways for disposing cadavers, ability to estimate minimum postmortem interval (PMI) using entomological data merits consideration. Chrysomya megacephala and Chrysomya rufifacies are common necrophagous species recovered from cadavers in many countries including Malaysia. Specific studies focusing on the oviposition and developmental patterns of both species on cadavers manifesting different levels of burn as described by the Crow-Glassman Scale (CGS) remain scarce. In four replicates, rabbit carcasses were burned to CGS levels #1, #2 and #3 by varying the amount of petrol used and duration of burning. Oviposition by C. megacephala and C. rufifacies was delayed by one day in the case of carcasses burned to the CGS level #3 (p0.05) in the duration of development were found between control and burned carcasses. These findings deserve consideration while estimating minimum PMI since burning as a mean for disposing animal and human cadavers is gaining popularity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. [Landmark-based automatic registration of serial cross-sectional images of Chinese digital human using Photoshop and Matlab software].

    Science.gov (United States)

    Su, Xiu-yun; Pei, Guo-xian; Yu, Bin; Hu, Yan-ling; Li, Jin; Huang, Qian; Li, Xu; Zhang, Yuan-zhi

    2007-12-01

    This paper describes automatic registration of the serial cross-sectional images of Chinese digital human by projective registration method based on the landmarks using the commercially available software Photoshop and Matlab. During cadaver embedment for acquisition of the Chinese digital human images, 4 rods were placed parallel to the vertical axis of the frozen cadaver to allow orientation. Projective distortion of the rod positions on the cross-sectional images was inevitable due to even slight changes of the relative position of the camera. The original cross-sectional images were first processed using Photoshop software firstly to obtain the images of the orientation rods, and the centroid coordinate of every rod image was acquired with Matlab software. With the average coordinate value of the rods as the fiducial point, two-dimensional projective transformation coefficient of each image was determined. Projective transformation was then carried out and projective distortion from each original serial image was eliminated. The rectified cross-sectional images were again processed using Photoshop to obtain the image of the first orientation rod, the coordinate value of first rod image was calculated using Matlab software, and the cross-sectional images were cut into images of the same size according to the first rod spatial coordinate, to achieve automatic registration of the serial cross-sectional images. sing Photoshop and Matlab softwares, projective transformation can accurately accomplish the image registration for the serial images with simpler calculation processes and easier computer processing.

  19. Is there a superior simulator for human anatomy education? How virtual dissection can overcome the anatomic and pedagogic limitations of cadaveric dissection.

    Science.gov (United States)

    Darras, Kathryn E; de Bruin, Anique B H; Nicolaou, Savvas; Dahlström, Nils; Persson, Anders; van Merriënboer, Jeroen; Forster, Bruce B

    2018-03-23

    Educators must select the best tools to teach anatomy to future physicians and traditionally, cadavers have always been considered the "gold standard" simulator for living anatomy. However, new advances in technology and radiology have created new teaching tools, such as virtual dissection, which provide students with new learning opportunities. Virtual dissection is a novel way of studying human anatomy through patient computed tomography (CT) scans. Through touchscreen technology, students can work together in groups to "virtually dissect" the CT scans to better understand complex anatomic relationships. This article presents the anatomic and pedagogic limitations of cadaveric dissection and explains what virtual dissection is and how this new technology may be used to overcome these limitations.

  20. Nudge, nudge or shove, shove-the right way for nudges to increase the supply of donated cadaver organs.

    Science.gov (United States)

    Whyte, Kyle Powys; Selinger, Evan; Caplan, Arthur L; Sadowski, Jathan

    2012-01-01

    Richard Thaler and Cass Sunstein (2008) contend that mandated choice is the most practical nudge for increasing organ donation. We argue that they are wrong, and their mistake results from failing to appreciate how perceptions of meaning can influence people's responses to nudges. We favor a policy of default to donation that is subject to immediate family veto power, includes options for people to opt out (and be educated on how to do so), and emphasizes the role of organ procurement organizations and in-house transplant donation coordinators creating better environments for increasing the supply of organs and tissues obtained from cadavers. This policy will provide better opportunities for offering nudges in contexts where in-house coordinators work with families. We conclude by arguing that nudges can be introduced ethically and effectively into these contexts only if nudge designers collaborate with in-house coordinators and stakeholders.

  1. Pregnant woman and road safety: experimental crash test with post mortem human subject.

    Science.gov (United States)

    Delotte, Jerome; Behr, Michel; Thollon, Lionel; Arnoux, Pierre-Jean; Baque, Patrick; Bongain, Andre; Brunet, Christian

    2008-05-01

    Trauma affect between 3 and 7% of all pregnancies in industrialized countries, and the leading cause of these traumas is car crashes. The difficulty to appreciate physiologic and anatomic changes occurring during pregnancy explain that majority of studies were not based on anatomical data. We present a protocol to create a realistic anatomical model of pregnant woman using a post mortem human subject (PMHS). We inserted a physical model of the gravid uterus into the pelvis of a PMHS. 3D acceleration sensors were placed on the subject to measure the acceleration on different body segments. We simulated three frontal impact situations at 20 km/h between two average European cars. Two main kinematics events were identified as possible causes of injuries: lap belt loading and backrest impact. Cadaver experiments provide one interesting complementary approach to study injury mechanisms related to road accidents involving pregnant women. This anatomical accuracy makes it possible to progress in the field of safety devices.

  2. Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

    Science.gov (United States)

    Osterhoff, Georg; Dodd, Andrew E; Unno, Florence; Wong, Angus; Amiri, Shahram; Lefaivre, Kelly A; Guy, Pierre

    2016-11-01

    Sacroiliac screw fixation in elderly patients with pelvic fractures is prone to failure owing to impaired bone quality. Cement augmentation has been proposed as a possible solution, because in other anatomic areas this has been shown to reduce screw loosening. However, to our knowledge, this has not been evaluated for sacroiliac screws. We investigated the potential biomechanical benefit of cement augmentation of sacroiliac screw fixation in a cadaver model of osteoporotic bone, specifically with respect to screw loosening, construct survival, and fracture-site motion. Standardized complete sacral ala fractures with intact posterior ligaments in combination with ipsilateral upper and lower pubic rami fractures were created in osteoporotic cadaver pelves and stabilized by three fixation techniques: sacroiliac (n = 5) with sacroiliac screws in S1 and S2, cemented (n = 5) with addition of cement augmentation, and transsacral (n = 5) with a single transsacral screw in S1. A cyclic loading protocol was applied with torque (1.5 Nm) and increasing axial force (250-750 N). Screw loosening, construct survival, and sacral fracture-site motion were measured by optoelectric motion tracking. A sample-size calculation revealed five samples per group to be required to achieve a power of 0.80 to detect 50% reduction in screw loosening. Screw motion in relation to the sacrum during loading with 250 N/1.5 Nm was not different among the three groups (sacroiliac: 1.2 mm, range, 0.6-1.9; cemented: 0.7 mm, range, 0.5-1.3; transsacral: 1.1 mm, range, 0.6-2.3) (p = 0.940). Screw subsidence was less in the cemented group (3.0 mm, range, 1.2-3.7) compared with the sacroiliac (5.7 mm, range, 4.7-10.4) or transsacral group (5.6 mm, range, 3.8-10.5) (p = 0.031). There was no difference with the numbers available in the median number of cycles needed until failure; this was 2921 cycles (range, 2586-5450) in the cemented group, 2570 cycles (range, 2500-5107) for the sacroiliac specimens, and

  3. In vivo reconstruction of lumbar erector spinae architecture using diffusion tensor MRI

    NARCIS (Netherlands)

    Sieben, Judith M.; Van Otten, Ilse; Lataster, Arno; Froeling, Martijn; Nederveen, Aart J.; Strijkers, Gustav J.; Drost, Maarten R.

    2016-01-01

    Study Design: Diffusion tensor magnetic resonance imaging (DTMRI) reconstruction of lumbar erector spinae (ES) compared with cadaver dissection. Objective: The aim of this study was to reconstruct the human lumbar ES from in vivo DT-MRI measurements and to compare the results with literature and

  4. Effects of five hindfoot arthrodeses on foot and ankle motion: Measurements in cadaver specimens

    Science.gov (United States)

    Zhang, Kun; Chen, Yanxi; Qiang, Minfei; Hao, Yini

    2016-01-01

    Single, double, and triple hindfoot arthrodeses are used to correct hindfoot deformities and relieve chronic pain. However, joint fusion may lead to dysfunction in adjacent articular surfaces. We compared range of motion in adjacent joints before and after arthrodesis to determine the effects of each procedure on joint motion. The theory of moment of couple, bending moment and balanced loading was applied to each of 16 fresh cadaver feet to induce dorsiflexion, plantarflexion, internal rotation, external rotation, inversion, and eversion. Range of motion was measured with a 3-axis coordinate measuring machine in a control foot and in feet after subtalar, talonavicular, calcaneocuboid, double, or triple arthrodesis. All arthrodeses restricted mainly internal-external rotation and inversion-eversion. The restriction in a double arthrodesis was more than that in a single arthrodesis, but that in a calcaneocuboid arthrodesis was relatively low. After triple arthrodeses, the restriction on dorsiflexion and plantarflexion movements was substantial, and internal-external rotation and inversion-eversion were almost lost. Considering that different arthrodesis procedures cause complex, three-dimensional hindfoot motion reductions, we recommend talonavicular or calcaneocuboid arthrodesis for patients with well-preserved functions of plantarflexion/dorsiflexion before operation, subtalar or calcaneocuboid arthrodesis for patients with well-preserved abduction/adduction, and talonavicular arthrodesis for patients with well-preserved eversion/inversion. PMID:27752084

  5. Comparing the Scoring of Human Decomposition from Digital Images to Scoring Using On-site Observations.

    Science.gov (United States)

    Dabbs, Gretchen R; Bytheway, Joan A; Connor, Melissa

    2017-09-01

    When in forensic casework or empirical research in-person assessment of human decomposition is not possible, the sensible substitution is color photographic images. To date, no research has confirmed the utility of color photographic images as a proxy for in situ observation of the level of decomposition. Sixteen observers scored photographs of 13 human cadavers in varying decomposition stages (PMI 2-186 days) using the Total Body Score system (total n = 929 observations). The on-site TBS was compared with recorded observations from digital color images using a paired samples t-test. The average difference between on-site and photographic observations was -0.20 (t = -1.679, df = 928, p = 0.094). Individually, only two observers, both students with human decomposition based on digital images can be substituted for assessments based on observation of the corpse in situ, when necessary. © 2017 American Academy of Forensic Sciences.

  6. Mechanical properties of the human scalp in tension.

    Science.gov (United States)

    Falland-Cheung, Lisa; Scholze, Mario; Lozano, Pamela F; Ondruschka, Benjamin; Tong, Darryl C; Brunton, Paul A; Waddell, J Neil; Hammer, Niels

    2018-08-01

    Mechanical properties of the human scalp have not been investigated to a great extent with limited information available. The purpose of this study was to provide new baseline material data for human scalp tissue of various ages, which can be applied to experimental and constitutive models, such as in the area of impact biomechanics. This study used specimens from the left and right temporal, fronto-parietal and occipital regions of the human scalp. It investigated the tensile behavior of scalp tissue using tissues harvested from unfixed, fresh cadavers. These samples were subjected to an osmotic stress analysis and upon testing, cyclic loading followed by stretching until failure in a universal testing machine. Strain evaluation was conducted using digital image correlation in a highly standardized approach. Elastic modulus, tensile strength, strain at maximum load and strain to failure were evaluated computationally. No significant differences were observed comparing the tensile strength between males and females. In contrast to that, a sex-dependent difference was found for the elastic modulus of the occipital scalp region and for the elongation properties. Additionally, regional differences within the male group, as well as an age dependent correlation for females were found in the elastic modulus and tensile strength. Scanning electron microscope analyses have shown the ultrastructural failure patterns, indicated by damaged keratin plates, as well as partially disrupted and retraced collagens at the failure site. The novel data obtained in this study could add valuable information to be used for modeling purposes, as well as provide baseline data for simulant materials and comparisons of tissue properties following head injury or forensic investigations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Study of physical, chemical and structural effects caused by ionizing radiation and preservation on human costal cartilage; Estudo dos efeitos fisicos, quimicos e estruturais ocasionados pela radiacao ionizante e preservacao em cartilagem costal humana

    Energy Technology Data Exchange (ETDEWEB)

    Martinho, Junior, Antonio Carlos

    2008-07-01

    Tissue Banks around the world have stored human cartilages obtained from cadaver donors for use in several kinds of reconstructive surgeries. To ensure that such tissues are not contaminated, they have been sterilized with ionizing radiation. However, high doses of gamma radiation may cause undesirable changes in the tissues, decreasing the mechanical properties of the grafts. In this work, we evaluate physical/chemical and structural changes in deep-frozen (-70 deg C) or high concentration of glycerol (> 98%) preserved costal cartilage, before and after sterilization by ionizing radiation at 3 different doses (15, 25 and 50 kGy). Samples of human costal cartilage were obtained from 20 cadaver donors ranging between 18 and 55 years old. A {sup 60}Co irradiator was used as irradiation source. Thermogravimetry (TG), Optical Coherence Tomography (OCT) and mechanical tension and compression tests were carried out to evaluate the changes in the cartilage. Regarding the thermogravimetric results, the obtained data has shown that the TG curves have the same pattern independently of the sample irradiated or not. On the other hand, non-irradiated samples showed great variability of thermogravimetric curves among different donors and for the same donor. Concerning the mechanical tests, when cartilages were irradiated with 15 kGy, their mechanical strength to tension was increased about 24%, in both deep-froze and preserved in glycerol samples. Samples deep-frozen, when irradiated with 25 and 50 kGy, presented a decrease of their mechanical behavior smaller than those preserved in high concentrations of glycerol and irradiated with the same dose. Therefore, deep-frozen cartilages can be sterilized with doses until 50 kGy and cartilages preserved in high concentrations of glycerol can be sterilized with doses until 25 kGy without significant changes in their bio-mechanical properties.(author)

  8. The development of neural stimulators: a review of preclinical safety and efficacy studies.

    Science.gov (United States)

    Shepherd, Robert K; Villalobos, Joel; Burns, Owen; Nayagam, David

    2018-05-14

    Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technology. The present review examines basic design principles associated with the development of a safe neural stimulator and describes the suite of preclinical safety studies that need to be considered when taking a device to clinical trial. Neural stimulators are active implantable devices that provide therapeutic intervention, sensory feedback or improved motor control via electrical stimulation of neural or neuro-muscular tissue in response to trauma or disease. Because of their complexity, regulatory bodies classify these devices in the highest risk category (Class III), and they are therefore required to go through a rigorous regulatory approval process before progressing to market. The successful development of these devices is achieved through close collaboration across disciplines including engineers, scientists and a surgical/clinical team, and the adherence to clear design principles. Preclinical studies form one of several key components in the development pathway from concept to product release of neural stimulators. Importantly, these studies provide iterative feedback in order to optimise the final design of the device. Key components of any preclinical evaluation include: in vitro studies that are focussed on device reliability and include accelerated testing under highly controlled environments; in vivo studies using animal models of the disease or injury in order to assess safety and, given an appropriate animal model, the efficacy of the technology under both passive and electrically active conditions; and human cadaver and ex vivo studies designed to ensure the device's form factor conforms to human anatomy, to optimise the surgical approach and to

  9. Effect of sodium lauryl sulfate (SLS) on in vitro percutaneous penetration of water, hydrocortisone and nickel

    DEFF Research Database (Denmark)

    Frankild, S; Andersen, Klaus Ejner; Nielsen, Gunnar

    1995-01-01

    The dose- and time-related effect of sodium lauryl sulfate (SLS) on in vitro percutaneous penetration was studied using 3 radiolabeled tracer compounds with different physicochemical properties: tritiated water, hydrocortisone and nickel. Human cadaver abdominal skin from caucasian women was used...

  10. An anatomical study of variations in termination of brachial artery, with its embryological basis and clinical significance

    Directory of Open Access Journals (Sweden)

    Deepa T. K

    2016-03-01

    Full Text Available The brachial artery is the main artery of the arm. It begins as the continuation of 3rd part of axillary artery, at the level of inferior border of teres major muscle. It ends at the level of the neck of radius by dividing into radial and ulnar arteries. In the present study we found higher division of brachial artery at mid arm level into its terminal branches with superficial course of radial artery. The present study was done on 51 cadavers from our dept. of Anatomy. The upper limbs of the cadaver were dissected and observed for any variations in the branching pattern of brachial artery. In the present study, a total number of 51 cadaver’s, 102 upper limbs were studied. In one male cadaver we found bilateral higher division of brachial artery, trifurcation on left side and bifurcation on right side brachial artery, with superficial course of radial artery. The knowledge of variation in origin and course of brachial artery is useful for orthopaedicians, physicians, radiologist, vascular and plastic surgeons.

  11. Development of a new biofidelity ranking system for anthropomorphic test devices.

    Science.gov (United States)

    Rhule, Heather H; Maltese, Matthew R; Donnelly, Bruce R; Eppinger, Rolf H; Brunner, Jill K; Bolte, John H

    2002-11-01

    A new biofidelity assessment system is being developed and applied to three side impact dummies: the WorldSID-alpha, the ES-2 and the SID-HIII. This system quantifies (1) the ability of a dummy to load a vehicle as a cadaver does, "External Biofidelity," and (2) the ability of a dummy to replicate those cadaver responses that best predict injury potential, "Internal Biofidelity." The ranking system uses cadaver and dummy responses from head drop tests, thorax and shoulder pendulum tests, and whole body sled tests. Each test condition is assigned a weight factor based on the number of human subjects tested to form the biomechanical response corridor and how well the biofidelity tests represent FMVSS 214, side NCAP (SNCAP) and FMVSS 201 Pole crash environments. For each response requirement, the cumulative variance of the dummy response relative to the mean cadaver response (DCV) and the cumulative variance of the mean cadaver response relative to the mean plus one standard deviation (CCV) are calculated. The ratio of DCV/CCV expresses how well the dummy response duplicates the mean cadaver response: a smaller ratio indicating better biofidelity. For each test condition, the square root is taken of each Response Comparison Value (DCV/CCV), and then these values are averaged and multiplied by the appropriate Test Condition Weight. The weighted and averaged comparison values are then summed and divided by the sum of the Test Condition Weights to obtain a rank for each body region. Each dummy obtains an overall rank for External Biofidelity and an overall rank for Internal Biofidelity comprised of an average of the ranks from each body region. Of the three dummies studied, the selected comparison test data indicate that the WorldSID-alpha prototype dummy demonstrated the best overall External Biofidelity although improvement is needed in all of the dummies to better replicate human kinematics. All three dummies estimate potential injury assessment with similar levels of

  12. Perceptions of cadaveric dissection in anatomy teaching.

    Science.gov (United States)

    Naz, Saima; Nazir, Ghazala; Iram, Samia; Mohammad, Malik; Umair; Qari, Iftikhar Hussain; Mohammad, Shaheen

    2011-01-01

    Anatomy professors world over are lamenting about medical students' lack of interest in dissections and its diminishing utilisation in medical studies. The objective of our study was to find out the reasons why some of the Pakistani medical students were avoiding dissections. We conducted this study in 5 medical colleges of Pakistan from Dec 2010-Oct 2011. Questionnaires were prepared and administered to more than 500 Pakistani medical students, at least 6 months after their first cadaver dissecting session. Mostly 1st and 2nd year medical students participated in this study. Around 43% students have actually performed dissections in some form, whereas around 57% had never touched the cadaver. Further evaluation of these results revealed that out of 57% of students, 45% avoided dissection due to bad smell of formaldehyde, 37% due to moral/ethical grounds, 22% due to low motivation and respect of human body, 19.4% due to anxiety, 18.6% due to religious reason, 16% due to fear, asthma and emotional reaction, 9.4% due to toxic chemical, 8.6% due to laziness and 7% due to nightmares. In spite of availability of required number of cadavers in all 5 medical colleges and a clear realisation amongst the students that dissecting cadaver is an effective way of learning anatomy; majority of students were not very keen and had therefore not performed dissection even once.

  13. The Effect of Polymethyl Methacrylate Augmentation on the Primary Stability of Cannulated Bone Screws in an Anterolateral Plate in Osteoporotic Vertebrae: A Human Cadaver Study.

    Science.gov (United States)

    Rüger, Matthias; Sellei, Richard M; Stoffel, Marcus; von Rüden, Christian

    2016-02-01

    Study Design Cohort study. Objective Expandable anterolateral plates facilitate the reduction of posttraumatic deformities of thoracolumbar spine injuries and are commonly used in cases of unstable injuries or compromised bone quality. In this in vitro study, the craniocaudal yield load of the osseous fixation of an anterior angular stable plate fixation system and the effect of polymethyl methacrylate (PMMA) screw augmentation on the primary stability of the screw-bone interface during kyphosis reduction was evaluated in 12 osteoporotic human thoracolumbar vertebrae. Methods The anterolateral stabilization device used for this study is comprised of two swiveling flanges and an expandable midsection. It facilitates the controlled reduction of kyphotic deformities in situ with a geared distractor. Single flanges were attached to 12 thoracolumbar vertebrae. Six specimens were augmented with PMMA by means of cannulated bone screws. The constructs were subjected to static, displacement-controlled craniocaudal loading to failure in a servohydraulic testing machine. Results The uncemented screws cut out at a mean 393 ± 66 N, whereas the cemented screws showed significantly higher yield load of 966 ± 166 N (p augmentation is an effective method to increase two- to threefold the primary stability of the screw-bone interface of an anterolateral spine stabilization system in osteoporotic bone. We recommend it in cases of severely compromised bone quality to reduce the risk of screw loosening during initial kyphosis correction and to increase long-term construct stability.

  14. Quantitative and qualitative analysis of cadaveric human pinealocytes in various age groups.

    Science.gov (United States)

    Rabia, Ansa; Tahir, Mohammad; Munir, Bushra; Sami, Waqas

    2011-07-01

    To determine age-related quantitative and qualitative changes in human pinealocytes using cadaveric material. Analytical cross-sectional study. The study was conducted in the Department of Anatomy, University of Health Sciences, Lahore, from January to December 2008. Thirty pineal glands from human cadavers ranging from 16-80 years of age were collected from mortuary of King Edward Medical University, Lahore, using purposive non-probability sampling. These were divided into three different age groups: I, II and III each between 16 to 30, 31 to 45 and 46 to 80 years of age respectively. Pinealocytes were counted; their mean diameter and that of their nuclei was calculated from a total of 30 cells per slide, using 4 μm thick H and E stained histological sections. Mean ± S.E.M. was calculated for quantitative variables. One-way ANOVA was applied to observe group mean differences among three groups. The number of pinealocytes decreased with aging but the difference was statistically insignificant when compared between groups (p=0.234). There was no change in size of pinealocyte soma and its nucleus (p=0.889 and 0.898 respectively). The number and size of pinealocytes, and their nuclei remained unaltered with advancing age.

  15. The availability of teaching–pedagogical resources used for promotion of learning in teaching human anatomy

    Science.gov (United States)

    Aragão, José Aderval; Fonseca-Barreto, Ana Terra; Brito, Ciro José; Guerra, Danilo Ribeiro; Nunes-Mota, José Carlos; Reis, Francisco Prado

    2013-01-01

    Five hundred students attending higher education institutions in northeastern Brazil responded to questionnaires about their anatomy classes; students represented a variety of different health sciences disciplines. Analysis of the responses revealed the participation of teaching assistants in a large percentage of classes and the use of teaching resources, particularly images, from conventional radiographs to magnetic resonance images. The number of classes for cadaver dissection and the number of students with access to that type of class were small. In most cases, dissection was performed according to anatomic regions or systems. Medicine and nursing students had the highest number of practical dissection classes. Most students were assessed using practical and theoretical tests. Findings revealed conditions similar to those found elsewhere. Resources should be renewed and used to improve teaching for students whose courses demand the study of human anatomy. PMID:24062622

  16. The availability of teaching-pedagogical resources used for promotion of learning in teaching human anatomy.

    Science.gov (United States)

    Aragão, José Aderval; Fonseca-Barreto, Ana Terra; Brito, Ciro José; Guerra, Danilo Ribeiro; Nunes-Mota, José Carlos; Reis, Francisco Prado

    2013-01-01

    Five hundred students attending higher education institutions in northeastern Brazil responded to questionnaires about their anatomy classes; students represented a variety of different health sciences disciplines. Analysis of the responses revealed the participation of teaching assistants in a large percentage of classes and the use of teaching resources, particularly images, from conventional radiographs to magnetic resonance images. The number of classes for cadaver dissection and the number of students with access to that type of class were small. In most cases, dissection was performed according to anatomic regions or systems. Medicine and nursing students had the highest number of practical dissection classes. Most students were assessed using practical and theoretical tests. Findings revealed conditions similar to those found elsewhere. Resources should be renewed and used to improve teaching for students whose courses demand the study of human anatomy.

  17. Robotic hip arthroscopy in human anatomy.

    Science.gov (United States)

    Kather, Jens; Hagen, Monika E; Morel, Philippe; Fasel, Jean; Markar, Sheraz; Schueler, Michael

    2010-09-01

    Robotic technology offers technical advantages that might offer new solutions for hip arthroscopy. Two hip arthroscopies were performed in human cadavers using the da Vinci surgical system. During both surgeries, a robotic camera and 5 or 8 mm da Vinci trocars with instruments were inserted into the hip joint for manipulation. Introduction of cameras and working instruments, docking of the robotic system and instrument manipulation was successful in both cases. The long articulating area of 5 mm instruments limited movements inside the joint; an 8 mm instrument with a shorter area of articulation offered an improved range of motion. Hip arthroscopy using the da Vinci standard system appears a feasible alternative to standard arthroscopy. Instruments and method of application must be modified and improved before routine clinical application but further research in this area seems justified, considering the clinical value of such an approach. Copyright 2010 John Wiley & Sons, Ltd.

  18. Trasplante renal con HLA idéntico de donante vivo y cadavérico: experiencia de la Fundación Valle de Lili, Cali, Colombia

    OpenAIRE

    Caicedo, Luis Armando; Gómez-Vega, Juan Carlos; Duque, Mauricio Francisco; Serrano, Óscar Javier; Manzi, Eliana; Arrunátegui, Ana María; Posada, Juan Guillermo; Mesa, Liliana; Schweineberg, Johanna; Durán, Carlos Eduardo; Villegas, Jorge Iván; Dávalos, Diana María; Echeverri, Gabriel Jaime

    2016-01-01

    Introducción: En el trasplante renal con HLA idéntico los episodios de rechazo agudo son menores y tienen mejores tasas de supervivencia del injerto, comparado con los receptores con HLA no idéntico; a pesar de esto, persiste el dilema en cuanto al retiro o la disminución de la dosis de inmunosupresión. El objetivo de este trabajo es describir la experiencia de los trasplantes renales con HLA idéntico de donante vivo y cadavérico que se han realizado en la Fundación Valle del Lili desde 1995 ...

  19. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    Science.gov (United States)

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Vascular Complications of Intercavernous Sinuses during Transsphenoidal Surgery: An Anatomical Analysis Based on Autopsy and Magnetic Resonance Venography.

    Science.gov (United States)

    Deng, Xuefei; Chen, Shijun; Bai, Ya; Song, Wen; Chen, Yongchao; Li, Dongxue; Han, Hui; Liu, Bin

    2015-01-01

    Vascular complications induced by intercavernous sinus injury during dural opening in the transsphenoidal surgery may contribute to incomplete tumour resections. Preoperative neuro-imaging is of crucial importance in planning surgical approach. The aim of this study is to correlate the microanatomy of intercavernous sinuses with its contrast-enhanced magnetic resonance venography (CE-MRV). Eighteen human adult cadavers and 24 patients were examined based on autopsy and CE-MRV. Through dissection of the cadavers and CE-MRV, the location, shape, number, diameter and type of intercavernous sinuses were measured and compared. Different intercavernous sinuses were identified by their location and shape in all the cadavers and CE-MRV. Compared to the cadavers, CE-MRV revealed 37% of the anterior intercavernous sinus, 48% of the inferior intercavernous sinus, 30% of the posterior intercavernous sinus, 30% of the dorsum sellae sinus and 100% of the basilar sinus. The smaller intercavernous sinuses were not seen in the neuro-images. According to the presence of the anterior and inferior intercavernous sinus, four types of the intercavernous sinuses were identified in cadavers and CE-MRV, and the corresponding operative space in the transsphenoidal surgical approach was implemented. The morphology and classification of the cavernous sinus can be identified by CE-MRV, especially for the larger vessels, which cause bleeding more easily. Therefore, CE-MRV provides a reliable measure for individualized preoperative planning during transsphenoidal surgery.