WorldWideScience

Sample records for human cadaver head

  1. Dynamic Response and Residual Helmet Liner Crush Using Cadaver Heads and Standard Headforms.

    Science.gov (United States)

    Bonin, S J; Luck, J F; Bass, C R; Gardiner, J C; Onar-Thomas, A; Asfour, S S; Siegmund, G P

    2017-03-01

    Biomechanical headforms are used for helmet certification testing and reconstructing helmeted head impacts; however, their biofidelity and direct applicability to human head and helmet responses remain unclear. Dynamic responses of cadaver heads and three headforms and residual foam liner deformations were compared during motorcycle helmet impacts. Instrumented, helmeted heads/headforms were dropped onto the forehead region against an instrumented flat anvil at 75, 150, and 195 J. Helmets were CT scanned to quantify maximum liner crush depth and crush volume. General linear models were used to quantify the effect of head type and impact energy on linear acceleration, head injury criterion (HIC), force, maximum liner crush depth, and liner crush volume and regression models were used to quantify the relationship between acceleration and both maximum crush depth and crush volume. The cadaver heads generated larger peak accelerations than all three headforms, larger HICs than the International Organization for Standardization (ISO), larger forces than the Hybrid III and ISO, larger maximum crush depth than the ISO, and larger crush volumes than the DOT. These significant differences between the cadaver heads and headforms need to be accounted for when attempting to estimate an impact exposure using a helmet's residual crush depth or volume.

  2. Human Cadaver Material in Preclinical Oral Surgery.

    Science.gov (United States)

    Barber, H. Dexter; And Others

    1993-01-01

    A University of Michigan dental school curriculum for oral surgery that uses human cadaver heads is described. Selection, preparation, and laboratory use of the materials are outlined. Faculty and students have received the sequence well and found it prepared them for clinical rotation. (MSE)

  3. Novel Application of Postmortem CT Angiography for Evaluation of the Intracranial Vascular Anatomy in Cadaver Heads.

    Science.gov (United States)

    van Eijk, Ruben P A; van der Zwan, Albert; Bleys, Ronald L A W; Regli, Luca; Esposito, Giuseppe

    2015-12-01

    Postmortem CT angiography is a common procedure used to visualize the entire human vasculature. For visualization of a specific organ's vascular anatomy, casting is the preferred method. Because of the permanent and damaging nature of casting, the organ cannot be further used as an experimental model after angiography. Therefore, there is a need for a minimally traumatic method to visualize organ-specific vascular anatomy. The purpose of this study was to develop and evaluate a contrast enhancement technique that is capable of visualizing the intracranial vascular anatomy while preserving the anatomic integrity in cadaver heads. Seven human heads were used in this study. Heads were prepared by cannulating the vertebral and internal carotid arteries. Contrast agent was injected as a mixture of tap water, polyethylene glycol 600, and an iodinated contrast agent. Postmortem imaging was executed on a 64-MDCT scanner. Primary image review and 3D reconstruction were performed on a CT workstation. Clear visualization of the major cerebral arteries and smaller intracranial branches was achieved. Adequate visualization was obtained for both the anterior and posterior intracranial circulation. The minimally traumatic angiography method preserved the vascular integrity of the cadaver heads. A novel application of postmortem CT angiography is presented here. The technique can be used for radiologic evaluation of the intracranial circulation in cadaver heads. After CT angiography, the specimen can be used for further experimental or laboratory testing and teaching purposes.

  4. Construction of tomographic head model using sectioned photographic images of cadaver

    International Nuclear Information System (INIS)

    Lee, Choon Sik; Lee, Jai Ki; Park, Jin Seo; Chung, Min Suk

    2004-01-01

    Tomographic models are currently the most complete, developed and realistic models of the human anatomy. They have been used to estimate organ doses for diagnostic radiation examination and radiotherapy treatment planning, and radiation protection. The quality of original anatomic images is a key factor to build a quality tomographic model. Computed tomography (CT) and magnetic resonance imaging (MRI) scan, from which most of current tomographic models are constructed, have their inherent shortcomings. In this study, a tomographic model of Korean adult male head was constructed by using serially sectioned photographs of cadaver. The cadaver was embedded, frozen, serially sectioned and photographed by high resolution digital camera at 0.2 mm interval. The contours of organs and tissues in photographs were segmented by several trained anatomists. The 120 segmented images of head at 2mm interval were converted into binary files and ported into Monte Carlo code to perform an example calculation of organ dose. Whole body tomographic model will be constructed by using the procedure developed in this study

  5. Schneiderian membrane detachment using transcrestal hydrodynamic ultrasonic cavitational sinus lift: a human cadaver head study and histologic analysis.

    Science.gov (United States)

    Troedhan, Angelo; Kurrek, Andreas; Wainwright, Marcel; Jank, Siegfried

    2014-08-01

    Recent studies have suggested the osteogenic layer of the periosteum at the base of the sinus membrane to play a key role in bone regeneration after sinus lift procedures. Thus, atraumatic detachment of the sinus membrane with an intact periosteum seems mandatory. The present histologic study of fresh human cadaver heads investigated the detachment behavior and histologic integrity of the detached periosteum after application of the transcrestal hydrodynamic ultrasonic cavitational sinus lift (tHUCSL-INTRALIFT). A total of 15 sinuses in 8 fresh human cadaver heads were treated using tHUCSL-INTRALIFT. After surgery, they were checked macroscopically for damage to the sinus membrane and then processed for histologic inspection under light microscopy. A total of 150 histologic specimens, randomly selected from the core surgical sites, were investigated using hematoxylin-eosin (HE), Azan, and trichrome staining. None of the 150 inspected specimens showed any perforation or dissection of the periosteum from the subepithelial connective tissue and respiratory epithelium and were fully detached from the bony antrum floor. The connecting Sharpey fibers revealed to be cleanly separated from the sinus floor in all specimens. The results of the present study suggest tHUCSL-INTRALIFT should be used to perform predictable and safe detachment of the periosteum from the bony sinus floor as a prerequisite for undisturbed and successful physiologic subantral bone regeneration. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Quantitative analysis of transcranial and intraparenchymal light penetration in human cadaver brain tissue.

    Science.gov (United States)

    Tedford, Clark E; DeLapp, Scott; Jacques, Steven; Anders, Juanita

    2015-04-01

    Photobiomodulation (PBM) also known as low-level light therapy has been used successfully for the treatment of injury and disease of the nervous system. The use of PBM to treat injury and diseases of the brain requires an in-depth understanding of light propagation through tissues including scalp, skull, meninges, and brain. This study investigated the light penetration gradients in the human cadaver brain using a Transcranial Laser System with a 30 mm diameter beam of 808 nm wavelength light. In addition, the wavelength-dependence of light scatter and absorbance in intraparenchymal brain tissue using 660, 808, and 940 nm wavelengths was investigated. Intact human cadaver heads (n = 8) were obtained for measurement of light propagation through the scalp/skull/meninges and into brain tissue. The cadaver heads were sectioned in either the transverse or mid-sagittal. The sectioned head was mounted into a cranial fixture with an 808 nm wavelength laser system illuminating the head from beneath with either pulsed-wave (PW) or continuous-wave (CW) laser light. A linear array of nine isotropic optical fibers on a 5 mm pitch was inserted into the brain tissue along the optical axis of the beam. Light collected from each fiber was delivered to a multichannel power meter. As the array was lowered into the tissue, the power from each probe was recorded at 5 mm increments until the inner aspect of the dura mater was reached. Intraparenchymal light penetration measurements were made by delivering a series of wavelengths (660, 808, and 940 nm) through a separate optical fiber within the array, which was offset from the array line by 5 mm. Local light penetration was determined and compared across the selected wavelengths. Unfixed cadaver brains provide good anatomical localization and reliable measurements of light scatter and penetration in the CNS tissues. Transcranial application of 808 nm wavelength light penetrated the scalp, skull, meninges, and brain

  7. Effects of human hair on trans-cranial focused ultrasound efficacy in an ex-vivo cadaver model

    Science.gov (United States)

    Hananel, Arik; Snell, John W.; Kassell, Neal F.; Eames, Matthew D. C.

    2012-11-01

    Current practice before a trans-cranial MR guided Focused ultrasound procedure is shaving the patient head on treatment day. Here we present an initial attempt to evaluate the feasibility of trans-cranial FUS, in an unshaved, ex-vivo cadaver skull. We have sonicated using 220kHz and 710kHz head transducers, a cadaver skull filled with tissue mimicking phantom and covered with a wig made of human hair to evaluate feasibility of acoustic energy transfer in a full size model. Heating at focal point was measured using MR proton resonance shift thermometry. Results showed negligible effect of hair in 220kHz, and an 18% drop in temperature elevation when using 710kHz.

  8. Accuracy of computer-guided implantation in a human cadaver model.

    Science.gov (United States)

    Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi

    2015-10-01

    To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  9. Still Human: A Call for Increased Focus on Ethical Standards in Cadaver Research.

    Science.gov (United States)

    Bach, Michelle C

    2016-12-01

    Research on human cadavers is an important mechanism of scientific progress and comprises a large industry in the United States. However, despite its importance and influence, there is little ethical or regulatory oversight of cadaver-based research. This lack of transparency raises important ethical questions. Thus, this paper serves as a call for ethicists and regulators to pay increased attention to cadaver research. I argue that cadaver research ought to be considered a subset of human subjects research and held accountable to higher ethical standards. After describing current practices, I argue that oversight of cadaver research as a form of human subjects research is appropriate because cadaver research is similar to other types of human research, participants in cadaver research incur risks of harm, and a current lack of oversight has allowed the cadaver industry to entice research participation through ethically questionable practices. This paper urges greater dialogue among human subjects research ethicists and regulators about what constitutes appropriate protections for participants in cadaver research.

  10. Use of human cadavers in teaching of human anatomy in brazilian medical faculties

    Directory of Open Access Journals (Sweden)

    Isabela de Sousa Leal Lopes

    2017-05-01

    Full Text Available The Human Anatomy is the study of human body structure and it has been related to the use of cadavers through the history. The aim of this research was to investigate the use of human cadavers in practical classes of human anatomy in Brazilian medical schools, and it was also made the identification of alternative methodologies and new technologies applied to the teaching of Anatomy. The research was conducted at the Faculdade Integral Diferencial from January to December of 2015. The population studied was composed by professors responsible for the Human Anatomy sector of the Brazilian medical faculties. It was addressed all the 242 medical colleges of the Brazil. It was obtained 81 answers. 96% of respondents reported make use of human corpses in its practical lessons of anatomy. It can be observed that 42% of the surveyed medical schools make use of only formaldehyde. 81% of faculties reported to face some difficulties to acquire human cadavers. 84% of medical schools make use of artificial models. 46% of faculties make use of diagnostic images. It can be concluded that human bodies, artificial models and new technologies are widely used in practical classes of anatomy in Brazil, since there is a difficulty to obtain cadavers.

  11. Insect Fauna of Human Cadavers in Tehran District

    Directory of Open Access Journals (Sweden)

    Fahimeh Talebzadeh

    2017-10-01

    Full Text Available Background: Entomological data can provide valuable information for crime scene investigations especially in post- mortem interval (PMI estimation. This study performed to determine insect fauna of human corpses in Tehran dis­trict.Methods: Insect specimens were collected from 12 human cadavers during spring and summer 2014 and were identi­fied using morphological characteristics.Results: Four fly species including two blowflies Chrysomya albiceps and Lucilia sericata (Calliphoridae, one flesh fly Sarcophaga argyrostoma (Sarcophagidae, and one phorid fly Megaselia scalaris (Phoridae and a beetle Der­mestes maculatus (Dermestidae was observed on the human cadavers. Chrysomya albiceps was the most dominant species on the corpses temporally and spatially.Conclusion: Chrysomya albiceps was the most dominant insect species on human cadavers in the area study spatio­temporally. The data make C. albiceps as a valuable entomological indicator for PMI estimation in Tehran and other parts of the country. However, further biological and ecological data such as its behavior, life tables, and consistent developmental time should be investigated when establishing a PMI in the region.

  12. A human cadaver fascial compartment pressure measurement model.

    Science.gov (United States)

    Messina, Frank C; Cooper, Dylan; Huffman, Gretchen; Bartkus, Edward; Wilbur, Lee

    2013-10-01

    Fresh human cadavers provide an effective model for procedural training. Currently, there are no realistic models to teach fascial compartment pressure measurement. We created a human cadaver fascial compartment pressure measurement model and studied its feasibility with a pre-post design. Three faculty members, following instructions from a common procedure textbook, used a standard handheld intra-compartment pressure monitor (Stryker(®), Kalamazoo, MI) to measure baseline pressures ("unembalmed") in the anterior, lateral, deep posterior, and superficial posterior compartments of the lower legs of a fresh human cadaver. The right femoral artery was then identified by superficial dissection, cannulated distally towards the lower leg, and connected to a standard embalming machine. After a 5-min infusion, the same three faculty members re-measured pressures ("embalmed") of the same compartments on the cannulated right leg. Unembalmed and embalmed readings for each compartment, and baseline readings for each leg, were compared using a two-sided paired t-test. The mean baseline compartment pressures did not differ between the right and left legs. Using the embalming machine, compartment pressure readings increased significantly over baseline for three of four fascial compartments; all in mm Hg (±SD): anterior from 40 (±9) to 143 (±44) (p = 0.08); lateral from 22 (±2.5) to 160 (±4.3) (p cadaver using a standard embalming machine. Set-up is minimal and the model can be incorporated into teaching curricula. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Prediction and analysis of human thoracic impact responses and injuries in cadaver impacts using a full human body finite element model.

    Science.gov (United States)

    Ruan, Jesse; El-Jawahri, Raed; Chai, Li; Barbat, Saeed; Prasad, Priya

    2003-10-01

    Human thoracic dynamic responses and injuries associated with frontal impact, side impact, and belt loading were investigated and predicted using a complete human body finite element model for an average adult male. The human body model was developed to study the impact biomechanics of a vehicular occupant. Its geometry was based on the Visible Human Project (National Library of Medicine) and the topographies from human body anatomical texts. The data was then scaled to an average adult male according to available biomechanical data from the literature. The model includes details of the head, neck, ribcage, abdomen, thoracic and lumbar spine, internal organs of the chest and abdomen, pelvis, and the upper and lower extremities. The present study is focused on the dynamic response and injuries of the thorax. The model was validated at various impact speeds by comparing predicted responses with available experimental cadaver data in frontal and side pendulum impacts, as well as belt loading. Model responses were compared with similar individual cadaver tests instead of using cadaver corridors because the large differences between the upper and lower bounds of the corridors may confound the model validation. The validated model was then used to study thorax dynamic responses and injuries in various simulated impact conditions. Parameters that could induce injuries such as force, deflection, and stress were computed from model simulations and were compared with previously proposed thoracic injury criteria to assess injury potential for the thorax. It has been shown that the model exhibited speed sensitive impact characteristics, and the compressibility of the internal organs significantly influenced the overall impact response in the simulated impact conditions. This study demonstrates that the development of a validated FE human body model could be useful for injury assessment in various cadaveric impacts reported in the literature. Internal organ injuries, which are

  14. The ethics of human cadaver organ transplantation: a biologist's viewpoint.

    Science.gov (United States)

    Emson, H E

    1987-01-01

    The rights of the various individuals involved in decision-making in cadaver organ donation are considered, and there is discussion of the relation of human cadavers to the planetary biomass. I conclude that the rights of the potential recipient should outweigh those of the other parties concerned and that education and legislation should recognise and promote this. PMID:3669037

  15. Body composition of two human cadavers by neutron activation and chemical analysis

    International Nuclear Information System (INIS)

    Knight, G.S.; Beddoe, A.H.; Streat, S.J.; Hill, G.L.

    1986-01-01

    In vivo neutron activation analysis (NAA) is currently used to measure body composition in metabolic and nutritional studies in many clinical situations, but has not previously been validated by comparison with chemical analysis of human cadavers. Total body nitrogen (TBN) and chlorine (TBCl) were measured in two human cadavers by NAA before homogenization and chemical analysis (CHEM) after (cadaver 1: TBN, 1.47 NAA, 1.51 CHEM; TBCl, 0.144 NAA, 0.147 CHEM; cadaver 2: TBN, 0.576 NAA, 0.572 CHEM; TBCl, 0.0227 NAA, 0.0250 CHEM). The homogenates were also analyzed by NAA, and no significant differences were found, indicating that the effects of elemental inhomogeneity on the measurement of TBN and TBCl are insignificant. Total body water, fat, protein, minerals, and carbohydrates were measured chemically for each cadaver and compared with estimates for these compartments obtained from a body composition model, which when used in vivo involves NAA and tritium dilution. The agreement found justifies the use of the model for the measurement of changes in total body protein, water, and fat in sequential studies in groups of patients

  16. Using ATP-driven bioluminescence assay to monitor microbial safety in a contemporary human cadaver laboratory.

    Science.gov (United States)

    Benninger, Brion; Maier, Thomas

    2015-03-01

    The objective of this study was to utilize a cost-effective method for assessing the levels of bacterial, yeast, and mold activity during a human dissection laboratory course. Nowadays, compliance with safety regulations is policed by institutions at higher standards than ever before. Fear of acquiring an unknown infection is one of the top concerns of professional healthcare students, and it provokes anti-laboratory anxiety. Human cadavers are not routinely tested for bacteria and viruses prior to embalming. Human anatomy dissecting rooms that house embalmed cadavers are normally cleaned after the dissected cadavers have been removed. There is no evidence that investigators have ever assessed bacterial and fungal activities using adenosine triphosphate (ATP)-driven bioluminescence assays. A literature search was conducted on texts, journals, and websites regarding bacterial, yeast, and mold activities in an active cadaver laboratory. Midway into a clinical anatomy course, ATP bioluminescence assays were used to swab various sites within the dissection room, including entrance and exiting door handles, water taps, cadaver tables, counter tops, imaging material, X-ray box switches, and the cadaver surfaces. The results demonstrated very low activities on cadaver tables, washing up areas, and exiting door handles. There was low activity on counter tops and X-ray boxes. There was medium activity on the entrance door handles. These findings suggest an inexpensive and accurate method for monitoring safety compliance and microbial activity. Students can feel confident and safe in the environment in which they work. © 2014 Wiley Periodicals, Inc.

  17. Soul Anatomy: A virtual cadaver

    Directory of Open Access Journals (Sweden)

    Moaz Bambi

    2014-01-01

    Full Text Available In the traditional science of medicine and medical education, teaching human anatomy in the class has always been done using human cadavers. Not only does this violate human sanctity, but according to our research, it is not adequate to provide students with the alleged educational value that it is supposed to deliver. It is very cumbersome to organise all the aspects of cadaver care. Cadavers are also very limited when it comes to controlling their structures and any benefit is almost completely altered the first time the cadaver is used (dissected, and ironically, it is very weak at delivering actual real-life scenarios of a human body to students. Virtual anatomy has been a promising solution that many are counting on. But even today, we have not found a complete solution that combines all the benefits of using human cadavers and those introduced by its technical counterparts. "Soul Anatomy" aims to do just that. It brings the best of all worlds, from a natural intuitive control system, life-like feel of organs, precise accuracy in moving and controlling bodily structures, to the smallest details of being able to show medical information overlays from various medical databases connected to the internet; thus making use of technology in teaching human anatomy by providing a modern learning experience.

  18. Emotional response of undergraduates to cadaver dissection.

    Science.gov (United States)

    Wisenden, Patricia A; Budke, Katherine J; Klemetson, Chelsea J; Kurtti, Tana R; Patel, Chandi M; Schwantz, Trenda L; Wisenden, Brian D

    2018-03-01

    The most effective way to learn human anatomy is through cadaver dissection. Historically, cadaver dissection has been the provenance of professional schools. Increasingly, cadaver-based courses in human anatomy are shifting to the undergraduate level, which creates both problems and opportunities because of differences between undergraduate and graduate student populations. Anxiety associated with dissecting cadavers can create a barrier to learning, and ultimately, entry into the health and medical sciences for some demographic subpopulations of undergraduates. We surveyed 76 students in 2007 and 51 students in 2009 at four times in the semester to investigate the timing and sociodemographic predictors of anxiety over cadaver dissection. We followed this with a second survey of 44 students in 2014 to test the effect of humanization of cadaver donors (providing information about donor occupation and cause of death) to reduce student anxiety. Students experienced anxiety upon first exposure to cadaver dissection. Female students experienced greater anxiety than male students upon first exposure to cadavers but this effect was short-lived. Self-identified non-white, non-Christian students experienced sustained anxiety throughout the semester, likely because cadaver stress compounded social and financial stressors unique to international students. Humanization was effective in reducing anxiety in non-white, non-Christian students but had the unexpected effect of increasing anxiety in female students. We recommend that humanizing information be offered to students who seek it out, but not forced upon students for whom the information would only add to their stress. Clin. Anat. 31:224-230, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. A novel method to measure femoral component migration by computed tomography: a cadaver study.

    Science.gov (United States)

    Boettner, Friedrich; Sculco, Peter; Lipman, Joseph; Renner, Lisa; Faschingbauer, Martin

    2016-06-01

    Radiostereometric analysis (RSA) is the most accurate technique to measure implant migration. However, it requires special equipment, technical expertise and analysis software and has not gained wide acceptance. The current paper analyzes a novel method to measure implant migration utilizing widely available computer tomography (CT). Three uncemented total hip replacements were performed in three human cadavers and six tantalum beads were inserted into the femoral bone similar to RSA. Six different 28 mm heads (-3, 0, 2.5, 5.0, 7.5 and 10 mm) were added to simulate five reproducible translations (maximum total point migration) of the center of the head. Implant migration was measured in a 3-D analysis software (Geomagic Studio 7). Repeat manual reconstructions of the center of the head were performed by two investigators to determine repeatability and accuracy. The accuracy of measurements between the centers of two head sizes was 0.11 mm with a CI 95 % of 0.22 mm. The intra-observer repeatability was 0.13 mm (CI 95 % 0.25 mm). The interrater-reliability was 0.943. CT based measurement of head displacement in a cadaver model were highly accurate and reproducible.

  20. Femtosecond laser subsurface scleral treatment in cadaver human sclera and evaluation using two-photon and confocal microscopy

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Yan, Ying; Lian, Fuqiang; Kurtz, Ron; Juhasz, Tibor

    2016-03-01

    Glaucoma is the second-leading cause of blindness worldwide and is often associated with elevated intraocular pressure (IOP). Partial-thickness drainage channels can be created with femtosecond laser in the translucent sclera for the potential treatment of glaucoma. We demonstrate the creation of partial-thickness subsurface drainage channels with the femtosecond laser in the cadaver human eyeballs and describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. A femtosecond laser operating at a wavelength of 1700 nm was scanned along a rectangular raster pattern to create the partial thickness subsurface drainage channels in the sclera of cadaver human eyes. Analysis of the dimensions and location of these channels is important in understanding their effects. We describe the application of two-photon microscopy and confocal microscopy for noninvasive imaging of the femtosecond laser created partial-thickness scleral channels in cadaver human eyes. High-resolution images, hundreds of microns deep in the sclera, were obtained to allow determination of the shape and dimension of such partial thickness subsurface scleral channels. Our studies suggest that the confocal and two-photon microscopy can be used to investigate femtosecond-laser created partial-thickness drainage channels in the sclera of cadaver human eyes.

  1. Laparoscopic training model using fresh human cadavers without the establishment of penumoperitoneum

    Directory of Open Access Journals (Sweden)

    Ernesto Sasaki Imakuma

    2016-01-01

    Full Text Available Background: Laparoscopy is a well-established alternative to open surgery for treating many diseases. Although laparoscopy has many advantages, it is also associated with disadvantages, such as slow learning curves and prolonged operation time. Fresh frozen cadavers may be an interesting resource for laparoscopic training, and many institutions have access to cadavers. One of the main obstacles for the use of cadavers as a training model is the difficulty in introducing a sufficient pneumoperitoneum to distend the abdominal wall and provide a proper working space. The purpose of this study was to describe a fresh human cadaver model for laparoscopic training without requiring a pneumoperitoneum. Materials and Methods and Results: A fake abdominal wall device was developed to allow for laparoscopic training without requiring a pneumoperitoneum in cadavers. The device consists of a table-mounted retractor, two rail clamps, two independent frame arms, two adjustable handle and rotating features, and two frames of the abdominal wall. A handycam is fixed over a frame arm, positioned and connected through a USB connection to a television and dissector; scissors and other laparoscopic materials are positioned inside trocars. The laparoscopic procedure is thus simulated. Conclusion: Cadavers offer a very promising and useful model for laparoscopic training. We developed a fake abdominal wall device that solves the limitation of space when performing surgery on cadavers and removes the need to acquire more costly laparoscopic equipment. This model is easily accessible at institutions in developing countries, making it one of the most promising tools for teaching laparoscopy.

  2. Prediction of skull fracture risk for children 0-9 months old through validated parametric finite element model and cadaver test reconstruction.

    Science.gov (United States)

    Li, Zhigang; Liu, Weiguo; Zhang, Jinhuan; Hu, Jingwen

    2015-09-01

    Skull fracture is one of the most common pediatric traumas. However, injury assessment tools for predicting pediatric skull fracture risk is not well established mainly due to the lack of cadaver tests. Weber conducted 50 pediatric cadaver drop tests for forensic research on child abuse in the mid-1980s (Experimental studies of skull fractures in infants, Z Rechtsmed. 92: 87-94, 1984; Biomechanical fragility of the infant skull, Z Rechtsmed. 94: 93-101, 1985). To our knowledge, these studies contained the largest sample size among pediatric cadaver tests in the literature. However, the lack of injury measurements limited their direct application in investigating pediatric skull fracture risks. In this study, 50 pediatric cadaver tests from Weber's studies were reconstructed using a parametric pediatric head finite element (FE) model which were morphed into subjects with ages, head sizes/shapes, and skull thickness values that reported in the tests. The skull fracture risk curves for infants from 0 to 9 months old were developed based on the model-predicted head injury measures through logistic regression analysis. It was found that the model-predicted stress responses in the skull (maximal von Mises stress, maximal shear stress, and maximal first principal stress) were better predictors than global kinematic-based injury measures (peak head acceleration and head injury criterion (HIC)) in predicting pediatric skull fracture. This study demonstrated the feasibility of using age- and size/shape-appropriate head FE models to predict pediatric head injuries. Such models can account for the morphological variations among the subjects, which cannot be considered by a single FE human model.

  3. History and future of human cadaver preservation for surgical training: from formalin to saturated salt solution method.

    Science.gov (United States)

    Hayashi, Shogo; Naito, Munekazu; Kawata, Shinichi; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Itoh, Masahiro

    2016-01-01

    Traditionally, surgical training meant on-the-job training with live patients in an operating room. However, due to advancing surgical techniques, such as minimally invasive surgery, and increasing safety demands during procedures, human cadavers have been used for surgical training. When considering the use of human cadavers for surgical training, one of the most important factors is their preservation. In this review, we summarize four preservation methods: fresh-frozen cadaver, formalin, Thiel's, and saturated salt solution methods. Fresh-frozen cadaver is currently the model that is closest to reality, but it also presents myriad problems, including the requirement of freezers for storage, limited work time because of rapid putrefaction, and risk of infection. Formalin is still used ubiquitously due to its low cost and wide availability, but it is not ideal because formaldehyde has an adverse health effect and formalin-embalmed cadavers do not exhibit many of the qualities of living organs. Thiel's method results in soft and flexible cadavers with almost natural colors, and Thiel-embalmed cadavers have been appraised widely in various medical disciplines. However, Thiel's method is relatively expensive and technically complicated. In addition, Thiel-embalmed cadavers have a limited dissection time. The saturated salt solution method is simple, carries a low risk of infection, and is relatively low cost. Although more research is needed, this method seems to be sufficiently useful for surgical training and has noteworthy features that expand the capability of clinical training. The saturated salt solution method will contribute to a wider use of cadavers for surgical training.

  4. Transformation of a Cadaver Population: Analysis of a South African Cadaver Program, 1921-2013

    Science.gov (United States)

    Kramer, Beverley; Hutchinson, Erin F.

    2015-01-01

    Anatomy has served as a cornerstone in the training of various allied and clinical disciplines and has traditionally been based on dissection of the human body. Thus, to pursue this method of teaching and learning, access to cadavers is of continuing importance. Over a significant period of time unclaimed cadavers have performed an essential role…

  5. Construct Validity of Fresh Frozen Human Cadaver as a Training Model in Minimal Access Surgery

    Science.gov (United States)

    Macafee, David; Pranesh, Nagarajan; Horgan, Alan F.

    2012-01-01

    Background: The construct validity of fresh human cadaver as a training tool has not been established previously. The aims of this study were to investigate the construct validity of fresh frozen human cadaver as a method of training in minimal access surgery and determine if novices can be rapidly trained using this model to a safe level of performance. Methods: Junior surgical trainees, novices (cadavers. Expert laparoscopists (>100 laparoscopic procedures) performed 3 repetitions of identical tasks. Performances were scored using a validated, objective Global Operative Assessment of Laparoscopic Skills scale. Scores for 3 consecutive repetitions were compared between experts and novices to determine construct validity. Furthermore, to determine if the novices reached a safe level, a trimmed mean of the experts score was used to define a benchmark. Mann-Whitney U test was used for construct validity analysis and 1-sample t test to compare performances of the novice group with the benchmark safe score. Results: Ten novices and 2 experts were recruited. Four out of 5 tasks (nondominant to dominant hand transfer; simulated appendicectomy; intracorporeal and extracorporeal knot tying) showed construct validity. Novices’ scores became comparable to benchmark scores between the eighth and tenth repetition. Conclusion: Minimal access surgical training using fresh frozen human cadavers appears to have construct validity. The laparoscopic skills of novices can be accelerated through to a safe level within 8 to 10 repetitions. PMID:23318058

  6. Development of a human cadaver model for training in laparoscopic donor nephrectomy.

    Science.gov (United States)

    Sutton, Erica R H; Billeter, Adrian; Druen, Devin; Roberts, Henry; Rice, Jonathan

    2017-06-01

    The organ procurement network recommends a surgeon record 15 cases as surgeon or assistant for laparoscopic donor nephrectomies (LDN) prior to independent practice. The literature suggests that the learning curve for improved perioperative and patient outcomes is closer to 35 cases. In this article, we describe our development of a model utilizing fresh tissue and objective, quantifiable endpoints to document surgical progress, and efficiency in each of the major steps involved in LDN. Phase I of model development focused on the modifications necessary to maintain visualization for laparoscopic surgery in a human cadaver. Phase II tested proposed learner-based metrics of procedural competency for multiport LDN by timing procedural steps of LDN in a novice learner. Phases I and II required 12 and nine cadavers, with a total of 35 kidneys utilized. The following metrics improved with trial number for multiport LDN: time taken for dissection of the gonadal vein, ureter, renal hilum, adrenal and lumbrical veins, simulated warm ischemic time (WIT), and operative time. Human cadavers can be used for training in LDN as evidenced by improvements in timed learner-based metrics. This simulation-based model fills a gap in available training options for surgeons. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Flies (Calliphoridae, Muscidae and Beetles (Silphidae from Human Cadavers in Cali, Colombia

    Directory of Open Access Journals (Sweden)

    Barreto Mauricio

    2002-01-01

    Full Text Available Adult specimens of Cochliomyia macellaria, Chrysomya megacephala, Ch. rufifacies, Lucilia sp. (Calliphoridae, Musca domestica (Muscidae, Oxelytrum discicolle (Silphidae and Sarcophagidae were recovered from 12 human cadavers in Cali, Valle, Colombia. Information regarding these findings is presented.

  8. Student Perceptions of an Upper-Level, Undergraduate Human Anatomy Laboratory Course without Cadavers

    Science.gov (United States)

    Wright, Shirley J.

    2012-01-01

    Several programs in health professional education require or are considering requiring upper-level human anatomy as prerequisite for their applicants. Undergraduate students are confronted with few institutions offering such a course, in part because of the expense and logistical issues associated with a cadaver-based human anatomy course. This…

  9. The Utility of Cadaver-Based Approaches for the Teaching of Human Anatomy: A Survey of British and Irish Anatomy Teachers

    Science.gov (United States)

    Balta, Joy Y.; Cronin, Michael; Cryan, John F.; O'Mahony, Siobhain M.

    2017-01-01

    Utilizing reality anatomy such as dissection and demonstrating using cadavers has been described as a superior way to create meaning. The chemicals used to embalm cadavers differentially alter the tissue of the human body, which has led to the usage of different processes along the hard to soft-fixed spectrum of preserved cadavers. A questionnaire…

  10. Anatomical study of prefixed versus postfixed brachial plexuses in adult human cadaver.

    Science.gov (United States)

    Guday, Edengenet; Bekele, Asegedech; Muche, Abebe

    2017-05-01

    The brachial plexus is usually formed by the fusion of anterior primary rami of the fifth to eighth cervical and the first thoracic spinal nerves. Variations in the formation of the brachial plexus may occur. Variations in brachial plexus anatomy are important to radiologists, surgeons and anaesthesiologists performing surgical procedures in the neck, axilla and upper limb regions. These variations may lead to deviation from the expected dermatome distribution as well as differences in the motor innervation of muscles of the upper limb. This study is aimed to describe the anatomical variations of brachial plexus in its formation among 20 Ethiopian cadavers. Observational based study was conducted by using 20 cadavers obtained from the Department of Human Anatomy at University of Gondar, Bahir Dar, Addis Ababa, Hawasa, Hayat Medical College and St Paul Hospital Millennium Medical College. Data analysis was conducted using thematic approaches. A total of 20 cadavers examined bilaterally for the formation of brachial plexus. Of the 40 sides, 30 sides (75%) were found normal, seven sides (17.5%) prefixed, three sides (7.5%) postfixed and one side of the cadaver lacks cord formation. The brachial plexus formation in most subjects is found to be normal. Among the variants, the numbers of the prefixed brachial plexuses are greater than the postfixed brachial plexuses. © 2016 Royal Australasian College of Surgeons.

  11. Successful transplantation of in vitro expanded human cadaver corneal endothelial precursor cells on to a cadaver bovine's eye using a nanocomposite gel sheet.

    Science.gov (United States)

    Parikumar, Periyasamy; Haraguchi, Kazutoshi; Ohbayashi, Akira; Senthilkumar, Rajappa; Abraham, Samuel J K

    2014-05-01

    In vitro expansion of human corneal endothelial precursor (HCEP) cells has been reported via production of cell aggregated spheres. However, to translate this procedure in human patients warrants maintaining the position of the eyeballs facing down for 36 h, which is not feasible. In this study, we report a method using a nanocomposite (NC) gel sheet to accomplish the integration of HCEP cells to the endothelium of cadaver bovine's eyes. HCEP cells were isolated from the corneal endothelium of a cadaver human eye and then expanded using a thermoreversible gelation polymer (TGP) as reported earlier. For the study, three cadaver bovine eyes were used. The NC gel sheets were inserted into the bovine eyes', aligned and suture-fixed in position under the host endothelium. HCEP cells previously expanded in the TGP were harvested and injected using a 26-gauge syringe between the endothelium and the NC gel sheet. The eyes were left undisturbed for three hours following which the NC gel sheets were gently removed. The corneas were harvested and subjected to histopathological studies. Histopathological studies showed that all the three corneas used for NC gel sheet implantation showed the presence of engrafted HCEP cells, seen as multi-layered cells over the native endothelium of the bovine cornea. Examination of the NC gel sheets used for implantation showed that only very few corneal endothelial cells remained on the sheets amounting to what could be considered negligible. The use of the NC gel sheet makes HCEP cell transplantation feasible for human patients. Further in vitro basic studies followed by translational studies are necessary to bring this method for clinical application in appropriate indications.

  12. Human Cadavers vs. Multimedia Simulation: A Study of Student Learning in Anatomy

    Science.gov (United States)

    Saltarelli, Andrew J.; Roseth, Cary J.; Saltarelli, William A.

    2014-01-01

    Multimedia and simulation programs are increasingly being used for anatomy instruction, yet it remains unclear how learning with these technologies compares with learning with actual human cadavers. Using a multilevel, quasi-experimental-control design, this study compared the effects of "Anatomy and Physiology Revealed" (APR) multimedia…

  13. Coordinated Multiple Cadaver Use for Minimally Invasive Surgical Training

    Science.gov (United States)

    Blaschko, Sarah D.; Brooks, H. Mark; Dhuy, S. Michael; Charest-Shell, Cynthia; Clayman, Ralph V.

    2007-01-01

    Background: The human cadaver remains the gold standard for anatomic training and is highly useful when incorporated into minimally invasive surgical training programs. However, this valuable resource is often not used to its full potential due to a lack of multidisciplinary cooperation. Herein, we propose the coordinated multiple use of individual cadavers to better utilize anatomical resources and potentiate the availability of cadaver training. Methods: Twenty-two postgraduate surgeons participated in a robot-assisted surgical training course that utilized shared cadavers. All participants completed a Likert 4-scale satisfaction questionnaire after their training session. Cadaveric tissue quality and the quality of the training session related to this material were assessed. Results: Nine participants rated the quality of the cadaveric tissue as excellent, 7 as good, 5 as unsatisfactory, and 1 as poor. Overall, 72% of participants who operated on a previously used cadaver were satisfied with their training experience and did not perceive the previous use deleterious to their training. Conclusion: The coordinated use of cadavers, which allows for multiple cadaver use for different teaching sessions, is an excellent training method that increases availability of human anatomical material for minimally invasive surgical training. PMID:18237501

  14. Functional and Structural Succession of Soil Microbial Communities below Decomposing Human Cadavers

    Science.gov (United States)

    Cobaugh, Kelly L.; Schaeffer, Sean M.; DeBruyn, Jennifer M.

    2015-01-01

    The ecological succession of microbes during cadaver decomposition has garnered interest in both basic and applied research contexts (e.g. community assembly and dynamics; forensic indicator of time since death). Yet current understanding of microbial ecology during decomposition is almost entirely based on plant litter. We know very little about microbes recycling carcass-derived organic matter despite the unique decomposition processes. Our objective was to quantify the taxonomic and functional succession of microbial populations in soils below decomposing cadavers, testing the hypotheses that a) periods of increased activity during decomposition are associated with particular taxa; and b) human-associated taxa are introduced to soils, but do not persist outside their host. We collected soils from beneath four cadavers throughout decomposition, and analyzed soil chemistry, microbial activity and bacterial community structure. As expected, decomposition resulted in pulses of soil C and nutrients (particularly ammonia) and stimulated microbial activity. There was no change in total bacterial abundances, however we observed distinct changes in both function and community composition. During active decay (7 - 12 days postmortem), respiration and biomass production rates were high: the community was dominated by Proteobacteria (increased from 15.0 to 26.1% relative abundance) and Firmicutes (increased from 1.0 to 29.0%), with reduced Acidobacteria abundances (decreased from 30.4 to 9.8%). Once decay rates slowed (10 - 23 d postmortem), respiration was elevated, but biomass production rates dropped dramatically; this community with low growth efficiency was dominated by Firmicutes (increased to 50.9%) and other anaerobic taxa. Human-associated bacteria, including the obligately anaerobic Bacteroides, were detected at high concentrations in soil throughout decomposition, up to 198 d postmortem. Our results revealed the pattern of functional and compositional succession

  15. Measurement repeatability of tibial tuberosity-trochlear groove offset distance in red fox (Vulpes vulpes) cadavers

    DEFF Research Database (Denmark)

    Miles, James Edward; Jensen, Bente Rona; Kirpensteijn, Jolle

    2013-01-01

    . Animals-12 red fox (Vulpes vulpes) cadavers. Procedures-CT images of each hind limb in intact cadavers were obtained; at 1-week intervals, 3 reconstructions were performed that were based on 1 plane passing through the centers of the femoral head and medial condyle and parallel to the caudal femoral...

  16. The state of head injury biomechanics: past, present, and future part 2: physical experimentation.

    Science.gov (United States)

    Goldsmith, Werner; Monson, Kenneth L

    2005-01-01

    This presentation is the continuation of the article published in Critical Reviews of Biomedical Engineering, 29(5-6), 2001. That issue contained topics dealing with components and geometry of the human head, classification of head injuries, some early experimental studies, and tolerance considerations. It then dealt with head motion and load characterization, investigations during the period from 1939 to 1966, injury causation and early modeling efforts, the 1966 Head Injury Conference and its sequels, mechanical properties of solid tissues, fluid characterization, and early investigation of the mechanical properties of cranial materials. It continued with a description of the systematic investigations of solid cranial components and structural properties since 1966, fetal cranial properties, analytical head modeling, and numerical solutions of head injury. The paper concluded with experimental dynamic loading of human living and cadaver heads, dynamic loading of surrogate heads, and head injury mechanics. This portion of the paper describes physical head injury experimentation involving animals, primarily primates, human cadavers, volunteers, and inanimate physical models. In order to address the entire domain of head injury biomechanics in the two-part survey, it was intended that this information be supplemented by discussions of head injury tolerance and criteria, automotive and sports safety considerations, and the design of protective equipment, but Professor Goldsmith passed away before these sections could be completed. It is nevertheless anticipated that this attenuated installment will provide, in conjunction with the first part of the survey, a valuable resource for students and practitioners of head injury biomechanics.

  17. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  18. An evaluation of soil chemistry in human cadaver decomposition islands: Potential for estimating postmortem interval (PMI).

    Science.gov (United States)

    Fancher, J P; Aitkenhead-Peterson, J A; Farris, T; Mix, K; Schwab, A P; Wescott, D J; Hamilton, M D

    2017-10-01

    Soil samples from the Forensic Anthropology Research Facility (FARF) at Texas State University, San Marcos, TX, were analyzed for multiple soil characteristics from cadaver decomposition islands to a depth of 5centimeters (cm) from 63 human decomposition sites, as well as depths up to 15cm in a subset of 11 of the cadaver decomposition islands plus control soils. Postmortem interval (PMI) of the cadaver decomposition islands ranged from 6 to 1752 days. Some soil chemistry, including nitrate-N (NO 3 -N), ammonium-N (NH 4 -N), and dissolved inorganic carbon (DIC), peaked at early PMI values and their concentrations at 0-5cm returned to near control values over time likely due to translocation down the soil profile. Other soil chemistry, including dissolved organic carbon (DOC), dissolved organic nitrogen (DON), orthophosphate-P (PO 4 -P), sodium (Na + ), and potassium (K + ), remained higher than the control soil up to a PMI of 1752days postmortem. The body mass index (BMI) of the cadaver appeared to have some effect on the cadaver decomposition island chemistry. To estimate PMI using soil chemistry, backward, stepwise multiple regression analysis was used with PMI as the dependent variable and soil chemistry, body mass index (BMI) and physical soil characteristics such as saturated hydraulic conductivity as independent variables. Measures of soil parameters derived from predator and microbial mediated decomposition of human remains shows promise in estimating PMI to within 365days for a period up to nearly five years. This persistent change in soil chemistry extends the ability to estimate PMI beyond the traditionally utilized methods of entomology and taphonomy in support of medical-legal investigations, humanitarian recovery efforts, and criminal and civil cases. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Temporal and Spatial Impact of Human Cadaver Decomposition on Soil Bacterial and Arthropod Community Structure and Function

    Science.gov (United States)

    Singh, Baneshwar; Minick, Kevan J.; Strickland, Michael S.; Wickings, Kyle G.; Crippen, Tawni L.; Tarone, Aaron M.; Benbow, M. Eric; Sufrin, Ness; Tomberlin, Jeffery K.; Pechal, Jennifer L.

    2018-01-01

    As vertebrate carrion decomposes, there is a release of nutrient-rich fluids into the underlying soil, which can impact associated biological community structure and function. How these changes alter soil biogeochemical cycles is relatively unknown and may prove useful in the identification of carrion decomposition islands that have long lasting, focal ecological effects. This study investigated the spatial (0, 1, and 5 m) and temporal (3–732 days) dynamics of human cadaver decomposition on soil bacterial and arthropod community structure and microbial function. We observed strong evidence of a predictable response to cadaver decomposition that varies over space for soil bacterial and arthropod community structure, carbon (C) mineralization and microbial substrate utilization patterns. In the presence of a cadaver (i.e., 0 m samples), the relative abundance of Bacteroidetes and Firmicutes was greater, while the relative abundance of Acidobacteria, Chloroflexi, Gemmatimonadetes, and Verrucomicrobia was lower when compared to samples at 1 and 5 m. Micro-arthropods were more abundant (15 to 17-fold) in soils collected at 0 m compared to either 1 or 5 m, but overall, micro-arthropod community composition was unrelated to either bacterial community composition or function. Bacterial community structure and microbial function also exhibited temporal relationships, whereas arthropod community structure did not. Cumulative precipitation was more effective in predicting temporal variations in bacterial abundance and microbial activity than accumulated degree days. In the presence of the cadaver (i.e., 0 m samples), the relative abundance of Actinobacteria increased significantly with cumulative precipitation. Furthermore, soil bacterial communities and C mineralization were sensitive to the introduction of human cadavers as they diverged from baseline levels and did not recover completely in approximately 2 years. These data are valuable for understanding ecosystem

  20. Temporal and Spatial Impact of Human Cadaver Decomposition on Soil Bacterial and Arthropod Community Structure and Function

    Directory of Open Access Journals (Sweden)

    Baneshwar Singh

    2018-01-01

    Full Text Available As vertebrate carrion decomposes, there is a release of nutrient-rich fluids into the underlying soil, which can impact associated biological community structure and function. How these changes alter soil biogeochemical cycles is relatively unknown and may prove useful in the identification of carrion decomposition islands that have long lasting, focal ecological effects. This study investigated the spatial (0, 1, and 5 m and temporal (3–732 days dynamics of human cadaver decomposition on soil bacterial and arthropod community structure and microbial function. We observed strong evidence of a predictable response to cadaver decomposition that varies over space for soil bacterial and arthropod community structure, carbon (C mineralization and microbial substrate utilization patterns. In the presence of a cadaver (i.e., 0 m samples, the relative abundance of Bacteroidetes and Firmicutes was greater, while the relative abundance of Acidobacteria, Chloroflexi, Gemmatimonadetes, and Verrucomicrobia was lower when compared to samples at 1 and 5 m. Micro-arthropods were more abundant (15 to 17-fold in soils collected at 0 m compared to either 1 or 5 m, but overall, micro-arthropod community composition was unrelated to either bacterial community composition or function. Bacterial community structure and microbial function also exhibited temporal relationships, whereas arthropod community structure did not. Cumulative precipitation was more effective in predicting temporal variations in bacterial abundance and microbial activity than accumulated degree days. In the presence of the cadaver (i.e., 0 m samples, the relative abundance of Actinobacteria increased significantly with cumulative precipitation. Furthermore, soil bacterial communities and C mineralization were sensitive to the introduction of human cadavers as they diverged from baseline levels and did not recover completely in approximately 2 years. These data are valuable for understanding

  1. Cadaver embalming fluid for surgical training courses: modified Larssen solution.

    Science.gov (United States)

    Bilge, Okan; Celik, Servet

    2017-11-01

    10% Formalin (F10)-fixed cadavers have disadvantages such as disturbing smell, mucosal irritation, discoloration and rigidity. We aimed to determine a suitable, simple and cost-effective embalming method that preserves color, texture, pliability and flexibility of the tissues for a long time without a disturbing smell and mucosal irritation. The embalmed cadavers were expected to be durable against environmental effects, utilizable for multiple and repetitive surgical trainings and instrumentations. Eight male (six intact, two autopsied bodies) and four female (three intact and one imported trunk) human cadavers were preserved with modified Larssen solution (MLS). Preserved bodies were kept in the deep freezers at -18/-20 °C. Bodies were allowed to thaw at room temperature 3 days prior to use. They were used in postgraduate hands-on courses for several medical disciplines. Each course lasted at least 1 day and during this period the bodies were stayed at room temperature. Assessments of 30 trainers and 252 trainees were collected during the courses. Additionally, the organoleptic characteristics of the fresh frozen (FF), preserved with MLS and F10-fixed cadavers were compared. The colors of muscles, fasciae, fatty tissue, nerves and vessels were evaluated and life-like tissues of MLS cadavers were impressive. There were no obvious or disturbing smell and sign of putrefaction of the MLS cadavers. MLS is a sustainable and relatively affordable soft cadaver embalming method. Its application is same as in other conventional methods and does not need new equipment. This article indicates the success of the MLS method in human cadavers.

  2. A Qualitative Assessment of Human Cadavers Embalmed by Thiel's Method Used in Laparoscopic Training for Renal Resection

    Science.gov (United States)

    Rai, Bhavan Prasad; Tang, Benjie; Eisma, Roos; Soames, Roger W.; Wen, Haitao; Nabi, Ghulam

    2012-01-01

    Human cadaveric tissue is the fundamental substrate for basic anatomic and surgical skills training. A qualitative assessment of the use of human cadavers preserved by Thiel's method for a British Association of Urological Surgeons--approved, advanced laparoscopic renal resection skills training course is described in the present study. Four…

  3. A study on preparation of cross sectional anatomy specimen of cadaver

    International Nuclear Information System (INIS)

    Im, C. K.; Choi, B. I.; Park, J. H.; Chang, K. H.; Yeon, K. M.; Han, M. C.; Kim, C. W.

    1984-01-01

    With the advent of cross sectional image of CT, ultrasound and magnetic resonance, the need for knowledge of cross sectional anatomy is stranger than ever. To meet this need, preparation of cross sectional anatomy specimen using cadaver is indispensable, not only because it tis the real cut surface anatomy but also because overt limitations of radiographic image in both contrast and special resolution. Authors prepared cross sectional anatomy specimen using a male cadaver, comprising photographs and slides of the 60 cross cut slices from the head to the pelvis. After photography, each slices was embedded using transparent resin allowing permanent preservation of specimen without altering its original architecture. Author's unique method of preparation is presented and 4 representative specimens are illustrated comparing cadaver's CT image, cross cut surface photography, and photography of resin embedded slice of the same cut surface.

  4. Yield Strength Testing in Human Cadaver Nasal Septal Cartilage and L-Strut Constructs.

    Science.gov (United States)

    Liu, Yuan F; Messinger, Kelton; Inman, Jared C

    2017-01-01

    To our knowledge, yield strength testing in human nasal septal cartilage has not been reported to date. An understanding of the basic mechanics of the nasal septum may help surgeons decide how much of an L-strut to preserve and how much grafting is needed. To determine the factors correlated with yield strength of the cartilaginous nasal septum and to explore the association between L-strut width and thickness in determining yield strength. In an anatomy laboratory, yield strength of rectangular pieces of fresh cadaver nasal septal cartilage was measured, and regression was performed to identify the factors correlated with yield strength. To measure yield strength in L-shaped models, 4 bonded paper L-struts models were constructed for every possible combination of the width and thickness, for a total of 240 models. Mathematical modeling using the resultant data with trend lines and surface fitting was performed to quantify the associations among L-strut width, thickness, and yield strength. The study dates were November 1, 2015, to April 1, 2016. The factors correlated with nasal cartilage yield strength and the associations among L-strut width, thickness, and yield strength in L-shaped models. Among 95 cartilage pieces from 12 human cadavers (mean [SD] age, 67.7 [12.6] years) and 240 constructed L-strut models, L-strut thickness was the only factor correlated with nasal septal cartilage yield strength (coefficient for thickness, 5.54; 95% CI, 4.08-7.00; P cadaver nasal septal cartilage, L-strut thickness was significantly associated with yield strength. In a bonded paper L-strut model, L-strut thickness had a more important role in determining yield strength than L-strut width. Surgeons should consider the thickness of potential L-struts when determining the amount of cartilaginous septum to harvest and graft. NA.

  5. Treatment of middle ear ventilation disorders: sheep as animal model for stenting the human Eustachian tube--a cadaver study.

    Directory of Open Access Journals (Sweden)

    Felicitas Miller

    Full Text Available Eustachian tube disorders can lead to chronic otitis media with consecutive conductive hearing loss. To improve treatment and to develop new types of implants such as stents, an adequate experimental animal model is required. As the middle ear of sheep is known to be comparable to the human middle ear, the dimensions of the Eustachian tube in two strains of sheep were investigated. The Eustachian tube and middle ear of half heads of heathland and blackface sheep were filled with silicone rubber, blended with barium sulfate to induce X-ray visibility. Images were taken by digital volume tomography. The tubes were segmented, and a three-dimensional model of every Eustachian tube was generated. The lengths, diameters and shapes were determined. Additionally, the feasibility of endoscopic stent implantation and fixation was tested in cadaver experiments. The length of the tube between ostium pharyngeum and the isthmus and the diameters were comparable to published values for the human tube. The tube was easily accessible through the nose, and then stents could be implanted and fixed at the isthmus. The sheep appears to be a promising model for testing new stent treatments for middle ear ventilation disorders.

  6. Microbial Signatures of Cadaver Gravesoil During Decomposition.

    Science.gov (United States)

    Finley, Sheree J; Pechal, Jennifer L; Benbow, M Eric; Robertson, B K; Javan, Gulnaz T

    2016-04-01

    Genomic studies have estimated there are approximately 10(3)-10(6) bacterial species per gram of soil. The microbial species found in soil associated with decomposing human remains (gravesoil) have been investigated and recognized as potential molecular determinants for estimates of time since death. The nascent era of high-throughput amplicon sequencing of the conserved 16S ribosomal RNA (rRNA) gene region of gravesoil microbes is allowing research to expand beyond more subjective empirical methods used in forensic microbiology. The goal of the present study was to evaluate microbial communities and identify taxonomic signatures associated with the gravesoil human cadavers. Using 16S rRNA gene amplicon-based sequencing, soil microbial communities were surveyed from 18 cadavers placed on the surface or buried that were allowed to decompose over a range of decomposition time periods (3-303 days). Surface soil microbial communities showed a decreasing trend in taxon richness, diversity, and evenness over decomposition, while buried cadaver-soil microbial communities demonstrated increasing taxon richness, consistent diversity, and decreasing evenness. The results show that ubiquitous Proteobacteria was confirmed as the most abundant phylum in all gravesoil samples. Surface cadaver-soil communities demonstrated a decrease in Acidobacteria and an increase in Firmicutes relative abundance over decomposition, while buried soil communities were consistent in their community composition throughout decomposition. Better understanding of microbial community structure and its shifts over time may be important for advancing general knowledge of decomposition soil ecology and its potential use during forensic investigations.

  7. Formulated arthropod cadavers for pest suppression

    OpenAIRE

    2001-01-01

    Pesticidal and/or antimicrobial biological agent-infected arthropod cadavers are formulated by applying a coating agent once on the surface of the cadaver which either (a) prevents the cadavers from sticking together and/or rupturing or (b) acts as an adhesive for a powder or granule applied to the cadaver to prevent sticking and rupturing. The formulated cadavers maintain or improve infectivity, reproducibility, and survivability. The formulated cadavers can be partially desiccated to improv...

  8. Displacement of the medial meniscus within the passive motion characteristics of the human knee joint: an RSA study in human cadaver knees.

    NARCIS (Netherlands)

    Tienen, T. van; Buma, P.; Scholten, J.G.; Kampen, A. van; Veth, R.P.H.; Verdonschot, N.J.J.

    2005-01-01

    The objective of this study was to validate an in vitro human cadaver knee-joint model for the evaluation of the meniscal movement during knee-joint flexion. The question was whether our model showed comparable meniscal displacements to those found in earlier meniscal movement studies in vivo.

  9. Applied anatomic study of testicular veins in adult cadavers and in human fetuses

    Directory of Open Access Journals (Sweden)

    Luciano A. Favorito

    2007-04-01

    Full Text Available OBJECTIVES: Analyze the anatomic variations of the testicular veins in human cadavers and fetuses. MATERIALS AND METHODS: One hundred male adult cadavers and 24 fetuses were studied. Four anatomic aspects were considered: 1 Number of testicular veins, 2 The local of vein termination, 3 Type and number of collaterals present and 4 Testicular vein termination angle. RESULTS: Cadavers - Right side - One testicular vein occurred in 85% and 2 veins in 5% of the cases. There were communicating veins with the colon in 21% of the cases. Left side - One testicular vein occurred in 82%, two veins in 15%, three veins in 2% and four veins in 1% of the cases. There were communicating veins with the colon in 31% of the cases. Fetuses - Right side -One testicular vein occurred in all cases. This vein drained to the vena cava in 83.3% of the cases, to the junction of the vena cava with the renal vein in 12.5% and to the renal vein in 4.2%. There were communicating veins with the colon in 25% of the cases. Left side - One testicular vein occurred in 66.6% of the cases, and 2 veins in occurred 33.3%. Communicating veins with the colon were found in 41.6% of the cases. CONCLUSION: The testicular vein presents numeric variations and also variations in its local of termination. In approximately 30% of the cases, there are collaterals that communicate the testicular vein with retroperitoneal veins. These anatomic findings can help understanding the origin of varicocele and its recurrence after surgical interventions.

  10. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study.

    Science.gov (United States)

    De Crop, An; Bacher, Klaus; Van Hoof, Tom; Smeets, Peter V; Smet, Barbara S; Vergauwen, Merel; Kiendys, Urszula; Duyck, Philippe; Verstraete, Koenraad; D'Herde, Katharina; Thierens, Hubert

    2012-01-01

    To determine the correlation between the clinical and physical image quality of chest images by using cadavers embalmed with the Thiel technique and a contrast-detail phantom. The use of human cadavers fulfilled the requirements of the institutional ethics committee. Clinical image quality was assessed by using three human cadavers embalmed with the Thiel technique, which results in excellent preservation of the flexibility and plasticity of organs and tissues. As a result, lungs can be inflated during image acquisition to simulate the pulmonary anatomy seen on a chest radiograph. Both contrast-detail phantom images and chest images of the Thiel-embalmed bodies were acquired with an amorphous silicon flat-panel detector. Tube voltage (70, 81, 90, 100, 113, 125 kVp), copper filtration (0.1, 0.2, 0.3 mm Cu), and exposure settings (200, 280, 400, 560, 800 speed class) were altered to simulate different quality levels. Four experienced radiologists assessed the image quality by using a visual grading analysis (VGA) technique based on European Quality Criteria for Chest Radiology. The phantom images were scored manually and automatically with use of dedicated software, both resulting in an inverse image quality figure (IQF). Spearman rank correlations between inverse IQFs and VGA scores were calculated. A statistically significant correlation (r = 0.80, P chest radiography. © RSNA, 2011.

  11. A pilot study comparing the use of Thiel- and formalin-embalmed cadavers in the teaching of human anatomy.

    Science.gov (United States)

    Balta, Joy Y; Lamb, Clare; Soames, Roger W

    2015-01-01

    Formalin had traditionally been used to preserve human material to teach gross anatomy. In 2008 the Centre for Anatomy and Human Identification (CAHID) at the University of Dundee embarked on the use of the Thiel method of embalming. The aim of this pilot study was to assess the difference between formalin-embalmed cadavers (FEC) and Thiel-embalmed cadavers (TEC) used for teaching and surgical training. Three different questionnaires were prepared for data collection from undergraduate and postgraduate students and clinical staff. All undergraduate and postgraduate students as well as clinical staff commented on the appearance of the TEC. There was no overall consensus concerning the use of TEC, some respondents preferred TEC for the entire dissection, some only for certain areas such as the musculoskeletal system. On a technical level TEC were considered less hazardous then FEC by one-third of participants with fewer than 10% regarding TEC as more irritating than FEC. Psychologically, 32.7% of undergraduate students expressed the view that TEC made them feel more uncomfortable compared with FEC because of their life-like appearance. However, 57.1% of undergraduate students encountered the same uncomfortable feelings when viewing both TEC and FEC. The use of Thiel-embalmed cadavers to teach anatomy has an added value, though further research is required over longer periods of time to identify its best usage. © 2014 American Association of Anatomists.

  12. Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study.

    Science.gov (United States)

    Wagner, Franca; Wimmer, Wilhelm; Leidolt, Lars; Vischer, Mattheus; Weder, Stefan; Wiest, Roland; Mantokoudis, Georgios; Caversaccio, Marco D

    2015-01-01

    Cochlear implants (CIs) are standard treatment for postlingually deafened individuals and prelingually deafened children. This human cadaver study evaluated diagnostic usefulness, image quality and artifacts in 1.5T and 3T magnetic resonance (MR) brain scans after CI with a removable magnet. Three criteria (diagnostic usefulness, image quality, artifacts) were assessed at 1.5T and 3T in five cadaver heads with CI. The brain magnetic resonance scans were performed with and without the magnet in situ. The criteria were analyzed by two blinded neuroradiologists, with focus on image distortion and limitation of the diagnostic value of the acquired MR images. MR images with the magnet in situ were all compromised by artifacts caused by the CI. After removal of the magnet, MR scans showed an unequivocal artifact reduction with significant improvement of the image quality and diagnostic usefulness, both at 1.5T and 3T. Visibility of the brain stem, cerebellopontine angle, and parieto-occipital lobe ipsilateral to the CI increased significantly after magnet removal. The results indicate the possible advantages for 1.5T and 3T MR scanning of the brain in CI carriers with removable magnets. Our findings support use of CIs with removable magnets, especially in patients with chronic intracranial pathologies.

  13. Cat dissection and human cadaver prosection versus sculpting human structures from clay: A comparison of alternate approaches to human anatomy laboratory education

    Science.gov (United States)

    Waters, John R.

    Dissection and vivisection are traditional approaches to biology laboratory education. In the case of human anatomy teaching laboratories, there is a long tradition of using human and animal cadaver specimens in the classroom. In a review of the literature comparing traditional dissection and vivisection lessons to alternative lessons designed to reduce the time spent dissecting or the numbers of animals used, we conclude that it is difficult to come to any conclusion regarding the efficacy of different approaches. An analysis of the literature is confounded because many studies have very low statistical power or other methodological weaknesses, and investigators rely on a wide variety of testing instruments to measure an equally varied number of course objectives. Additional well designed studies are necessary before educators can reach any informed conclusions about the efficacy of traditional versus alternative approaches to laboratory education. In our experiments, we compared a traditional cat dissection based undergraduate human anatomy lesson to an alternative where students sculpted human muscles onto plastic human skeletons. Students in the alternative treatment performed significantly better than their peers in the traditional treatment when answering both lower and higher order human anatomy questions. In a subsequent experiment with a similar design, we concluded that the superior performance of the students in the alternative treatment on anatomy exams was likely due to the similarity between the human anatomy representation studied in lab, and the human anatomy questions asked on the exams. When the anatomy questions were presented in the context of a cat specimen, students in the traditional cat dissection treatment outperformed their peers in the alternative treatment. In a final experiment where student performance on a human anatomy exam was compared between a traditional prosected human cadaver treatment and the alternative clay sculpting

  14. Birth and death of human β-cells in pancreas from cadaver donors, autopsies, surgical specimens, and islets transplanted into mice

    Science.gov (United States)

    Caballero, Francisco; Siniakowicz, Karolina; Jennifer-Hollister-Lock; Duran, Luisa; Katsuta, Hitoshi; Yamada, Takatsugu; Lei, Ji; Deng, Shaoping; Westermark, Gunilla T.; Markmann, James; Bonner-Weir, Susan; Weir, Gordon C.

    2013-01-01

    There is great interest in the potential of the human endocrine pancreas for regeneration by β-cell replication or neogenesis. Our aim was to explore this potential in adult human pancreases and in both islet and exocrine tissue transplanted into mice. The design was to examine pancreases obtained from cadaver donors, autopsies and fresh surgical specimens and compare these findings with those obtained from islet and duct tissue grafted into the kidney. Islets and exocrine tissue were transplanted into normoglycemic ICR/SCID mice and studied 4 and 14 wk later. β-cell replication as assessed by double staining for insulin and Ki67 was 0.22 ± 0.03 % at 4 wk and 0.13 ± 0.03 % at 14 wk. In contrast, no evidence of β-cell replication could be found in 11 cadaver donor and 10 autopsy pancreases. However, Ki67 staining of β-cells in frozen sections obtained at surgery was comparable to that found in transplanted islets. Evidence for neogenesis in transplanted pancreatic exocrine tissue was supported by finding β-cells within the duct epithelium, and the presence of cells double stained for insulin and cytokeratin 19 (CK19). However, β-cells within the ducts never constituted more than 1% of the CK19 positive cells. With confocal microscopy, 7 of 12 examined cells expressed both markers, consistent with a neogeneic process. Mice with grafts containing islet or exocrine tissue were treated with various combinations exendin-4, gastrin and epidermal growth factor; none increased β-cell replication or stimulated neogenesis. In summary, human β-cells replicate at a low level in islets transplanted into mice and in surgical pancreatic frozen sections but rarely in cadaver donor or autopsy pancreases. The absence of β-cell replication in many adult cadaver or autopsy pancreases could, in part, be an artifact of the postmortem state. Thus, it appears that adult human β-cells maintain a low level of turnover through replication and neogenesis. PMID:23321263

  15. Birth and death of human β-cells in pancreases from cadaver donors, autopsies, surgical specimens, and islets transplanted into mice.

    Science.gov (United States)

    Caballero, Francisco; Siniakowicz, Karolina; Hollister-Lock, Jennifer; Duran, Luisa; Katsuta, Hitoshi; Yamada, Takatsugu; Lei, Ji; Deng, Shaoping; Westermark, Gunilla T; Markmann, James; Bonner-Weir, Susan; Weir, Gordon C

    2014-02-01

    There is great interest in the potential of the human endocrine pancreas for regeneration by β-cell replication or neogenesis. Our aim was to explore this potential in adult human pancreases and in both islet and exocrine tissue transplanted into mice. The design was to examine pancreases obtained from cadaver donors, autopsies, and fresh surgical specimens and compare these findings with those obtained from islet and duct tissue grafted into the kidney. Islets and exocrine tissue were transplanted into normoglycemic ICR-SCID mice and studied 4 and 14 weeks later. β-Cell replication, as assessed by double staining for insulin and Ki67, was 0.22 ± 0.03% at 4 weeks and 0.13 ± 0.03% at 14 weeks. In contrast, no evidence of β-cell replication could be found in 11 cadaver donor and 10 autopsy pancreases. However, Ki67 staining of β-cells in frozen sections obtained at surgery was comparable to that found in transplanted islets. Evidence for neogenesis in transplanted pancreatic exocrine tissue was supported by finding β-cells within the duct epithelium and the presence of cells double stained for insulin and cytokeratin 19 (CK19). However, β-cells within the ducts never constituted more than 1% of the CK19-positive cells. With confocal microscopy, 7 of 12 examined cells expressed both markers, consistent with a neogeneic process. Mice with grafts containing islet or exocrine tissue were treated with various combinations of exendin-4, gastrin, and epidermal growth factor; none increased β-cell replication or stimulated neogenesis. In summary, human β-cells replicate at a low level in islets transplanted into mice and in surgical pancreatic frozen sections, but rarely in cadaver donor or autopsy pancreases. The absence of β-cell replication in many adult cadaver or autopsy pancreases could, in part, be an artifact of the postmortem state. Thus, it appears that adult human β-cells maintain a low level of turnover through replication and neogenesis.

  16. A new substitute for formalin: Application to embalming cadavers.

    Science.gov (United States)

    Haizuka, Yoshinori; Nagase, Miki; Takashino, Satoshi; Kobayashi, Yasushi; Fujikura, Yoshihisa; Matsumura, George

    2018-01-01

    The development of formalin-free fixatives is an urgent issue in gross anatomy because of the health hazard and the tissue-hardening actions of formalin. We recently identified the fixative, antimicrobial, and preservative effects of N-vinyl-2-pyrrolidone (NVP), a precursor of the water-soluble macromolecular polymer polyvinylpyrrolidone, in animal experiments. The aim of the present study is to investigate whether NVP solution can be used as an alternative to formalin in human cadaveric dissection. Twelve donated cadavers were infused with NVP via the femoral and common carotid arteries using a peristaltic pump. Experienced teaching staff members in our department dissected the cadavers and examined their macroanatomical properties. The NVP-embalmed corpses showed no sign of decomposition or fungal growth. The bodies remained soft and flexible. Notably, the shoulder, elbow, wrist, phalangeal, hip, knee, cervical spine, and temporomandibular joints were highly mobile, almost equivalent to those of living individuals. The range of motion of most joints was greater in the NVP-fixed than formalin-fixed cadavers. Under the dermis, the subcutaneous fat was markedly reduced and the connective tissues were transparent, so the ligaments, cutaneous nerves, and veins were easily discernible. The abdominal wall and the visceral organs remained pliable and elastic, resembling those of fresh cadavers. The lungs, liver, and gastrointestinal tract were moveable in the thoracic and abdominal cavities and were readily isolated. NVP can be used successfully as a fixative and preservative solution for human cadavers; furthermore, NVP-embalmed bodies could be valuable for learning clinical skills and for training, and for developing innovative medical devices. Clin. Anat. 31:90-98, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  17. Morphometric Study of Vocal Folds in Indian Cadavers

    Directory of Open Access Journals (Sweden)

    Rawal J.D.

    2015-06-01

    Full Text Available Introduction: -The larynx is an air passage and a sphincteric device used in respiration and phonation. The larynx, from inside outwards has a framework of mucosa surrounded by fibro-elastic membrane which in turn is surrounded by cartilages and then a layer of muscles. Vocal folds are intrinsic ligament of larynx covered by mucosal folds. Larynx generates sound through rhythmic opening and closing of the vocal folds. The perceived pitch of human voice mainly depends upon fundamental frequency of sound generated by larynx. Aim: - The aim of present study is to measure various dimensions of vocal folds in Indian cadavers. Material & Methods: - 50 larynx were obtained from embalmed cadavers, of which 10 larynx were of females. Vocal cords were dissected from the larynx and morphometric analysis was done. Results and Conclusions: - The average total length of the vocal folds was found to be 16.11 mm. ± 2.62 mm. in male and 14.10 mm. ± 1.54 mm. in female cadavers. The average width of the vocal folds was found to be 4.38 mm. ± 0.74 mm. in male and 3.60 mm. ± 0.64 mm. in female cadavers. The average total length of the membranous part of the vocal folds was found to be 11.90 mm. ± 1.86 mm. in male and 10.45 mm. ± 1.81 mm. in female cadavers. The average ratio of the length of the membranous and the cartilaginous parts of the vocal folds was calculated to be 3.10 ± 0.96in male and 2.85 ± 0.73in female cadavers.

  18. Medical Students' Attitudinal Changes towards Cadaver Dissection ...

    African Journals Online (AJOL)

    Background: Recently, not only the medical school curriculum but also medical students' attitude towards cadaver-based learning of anatomy has changed. This investigation is therefore designed to analyse students' attitudes towards human cadaveric dissection before and after exposure to dissection. Methods: A ...

  19. Evaluation of automatic image quality assessment in chest CT - A human cadaver study.

    Science.gov (United States)

    Franck, Caro; De Crop, An; De Roo, Bieke; Smeets, Peter; Vergauwen, Merel; Dewaele, Tom; Van Borsel, Mathias; Achten, Eric; Van Hoof, Tom; Bacher, Klaus

    2017-04-01

    The evaluation of clinical image quality (IQ) is important to optimize CT protocols and to keep patient doses as low as reasonably achievable. Considering the significant amount of effort needed for human observer studies, automatic IQ tools are a promising alternative. The purpose of this study was to evaluate automatic IQ assessment in chest CT using Thiel embalmed cadavers. Chest CT's of Thiel embalmed cadavers were acquired at different exposures. Clinical IQ was determined by performing a visual grading analysis. Physical-technical IQ (noise, contrast-to-noise and contrast-detail) was assessed in a Catphan phantom. Soft and sharp reconstructions were made with filtered back projection and two strengths of iterative reconstruction. In addition to the classical IQ metrics, an automatic algorithm was used to calculate image quality scores (IQs). To be able to compare datasets reconstructed with different kernels, the IQs values were normalized. Good correlations were found between IQs and the measured physical-technical image quality: noise (ρ=-1.00), contrast-to-noise (ρ=1.00) and contrast-detail (ρ=0.96). The correlation coefficients between IQs and the observed clinical image quality of soft and sharp reconstructions were 0.88 and 0.93, respectively. The automatic scoring algorithm is a promising tool for the evaluation of thoracic CT scans in daily clinical practice. It allows monitoring of the image quality of a chest protocol over time, without human intervention. Different reconstruction kernels can be compared after normalization of the IQs. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Human cadaver retina model for retinal heating during corneal surgery with a femtosecond laser

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Yun, Jin; Zhao, Tianzhuo; Yan, Ying; Kurtz, Ron M.; Juhasz, Tibor

    2014-02-01

    Femtosecond lasers are widely used in everyday clinical procedures to perform minimally invasive corneal refractive surgery. The intralase femtosecond laser (AMO Corp. Santa Ana, CA) is a common example of such a laser. In the present study a numerical simulation was developed to quantify the temperature rise in the retina during femtosecond intracorneal surgery. Also, ex-vivo retinal heating due to laser irradiation was measured with an infrared thermal camera (Fluke Corp. Everett, WA) as a validation of the simulation. A computer simulation was developed using Comsol Multiphysics to calculate the temperature rise in the cadaver retina during femtosecond laser corneal surgery. The simulation showed a temperature rise of less than 0.3 degrees for realistic pulse energies for the various repetition rates. Human cadaver retinas were irradiated with a 150 kHz Intralase femtosecond laser and the temperature rise was measured withan infrared thermal camera. Thermal camera measurements are in agreement with the simulation. During routine femtosecond laser corneal surgery with normal clinical parameters, the temperature rise is well beneath the threshold for retina damage. The simulation predictions are in agreement with thermal measurements providing a level of experimental validation.

  1. Short-term effects of hydrated lime and quicklime on the decay of human remains using pig cadavers as human body analogues: Laboratory experiments.

    Science.gov (United States)

    Schotsmans, Eline M J; Denton, John; Fletcher, Jonathan N; Janaway, Robert C; Wilson, Andrew S

    2014-05-01

    Contradictions and misconceptions regarding the effect of lime on the decay of human remains have demonstrated the need for more research into the effect of different types of lime on cadaver decomposition. This study follows previous research by the authors who have investigated the effect of lime on the decomposition of human remains in burial environments. A further three pig carcasses (Sus scrofa), used as human body analogues, were observed and monitored for 78 days without lime, with hydrated lime (Ca(OH)2) and with quicklime (CaO) in the taphonomy laboratory at the University of Bradford. The results showed that in the early stages of decay, the unlimed and hydrated lime cadavers follow a similar pattern of changes. In contrast, the application of quicklime instigated an initial acceleration of decay. Microbial investigation demonstrated that the presence of lime does not eliminate all aerobic bacteria. The experiment also suggested that lime functions as a sink, buffering the carbon dioxide evolution. This study complements the field observations. It has implications for the investigation of time since death of limed remains. Knowledge of the effects of lime on decomposition processes is of interest to forensic pathologists, archaeologists, humanitarian organisations and those concerned with disposal of animal carcasses or human remains in mass disasters. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Medical students' reactions to anatomic dissection and the phenomenon of cadaver naming.

    Science.gov (United States)

    Williams, Austin D; Greenwald, Emily E; Soricelli, Rhonda L; DePace, Dennis M

    2014-01-01

    The teaching of gross anatomy has, for centuries, relied on the dissection of human cadavers, and this formative experience is known to evoke strong emotional responses. The authors hypothesized that the phenomenon of cadaver naming is a coping mechanism used by medical students and that it correlates with other attitudes about dissection and body donation. The authors developed a 33-question electronic survey to which 1,156 medical students at 12 medical schools in the United States voluntarily responded (November 2011-March 2012). They also surveyed course directors from each institution regarding their curricula and their observations of students' coping mechanisms. The majority of students (574, 67.8%) named their cadaver. Students most commonly cited the cadaver's age as the reason they chose a particular name for the cadaver. A minority of the students who did not name the cadaver reported finding the practice of naming disrespectful. Almost all students indicated that they would have liked to know more about their donor, particularly his or her medical history. Finally, students who knew the birth name of the donor used it less frequently than predicted. The authors found that the practice of naming cadavers is extremely prevalent among medical students and that inventive naming serves as a beneficial coping mechanism. The authors suggest that developing a method of providing students with more information about their cadaver while protecting the anonymity of the donor and family would be useful. © 2012 American Association of Anatomists.

  3. Medical Students' Reactions to Anatomic Dissection and the Phenomenon of Cadaver Naming

    Science.gov (United States)

    Williams, Austin D.; Greenwald, Emily E.; Soricelli, Rhonda L.; DePace, Dennis M.

    2014-01-01

    The teaching of gross anatomy has, for centuries, relied on the dissection of human cadavers, and this formative experience is known to evoke strong emotional responses. The authors hypothesized that the phenomenon of cadaver naming is a coping mechanism used by medical students and that it correlates with other attitudes about dissection and body…

  4. The Reliance on Unclaimed Cadavers for Anatomical Teaching by Medical Schools in Africa

    Science.gov (United States)

    Gangata, Hope; Ntaba, Phatheka; Akol, Princess; Louw, Graham

    2010-01-01

    The study of gross Anatomy through the use of cadaveric dissections in medical schools is an essential part of the comprehensive learning of human Anatomy, and unsurprisingly, 90% of the surveyed medical schools in Africa used cadaveric dissections. Donated cadavers now make up 80% of the total cadavers in North American medical schools and all…

  5. Death, cadavers and post-mortem biomedical research: a point of view from a Christian community.

    Science.gov (United States)

    Charlier, Philippe; Joly, Alain; Champagnat, Julie; Brun, Luc; de la Grandmaison, Geoffroy Lorin; Hervé, Christian

    2013-12-01

    Facing modern developments of medicine and biomedical researches, religious communities are a strong source of ethics principles and orientations. Human dignity does not disappear after life, in a context of biomedical research on cadavers. Moral, political, social and scientific aspects of research on human cadavers (mainly autopsies) have been widely discussed in biomedical publications, whereas the religious ones (which could be predominant for some) have rarely been analyzed and presented. This article will present the results of a survey carried out a French Benedictine Abbey (relative to death, cadaver's status and biomedical research) and subsequent Christian background according to canonic texts and practical cases from anthropological, historical, archeological and biomedical origin.

  6. [Cadavers and mummies as therapeutic means].

    Science.gov (United States)

    Massart, D; Sohawon, S; Noordally, O

    2010-01-01

    Sickness befallen onto him, man found that plant and animal derivatives invigorated him. Thereafter, he found a therapeutic benefit in using man as a means of self cure and especially, dead man from violent death. The foam of the skull of cadaver was an excellent antiepileptic as well as blood coming out from a freshly decapitated man. By applying on diseased parts of his body, so as to get rid of inflammation or infection, cadaver's hands were used against tumors of all kinds. Dead human skin were processed into belts and used therein for helping delivery of parturition women. The mummy must be blackish, foul smelling and hard. Those who were whitish, odorless and powder-like, were unfit for use. Mummy powder applied to the nose would stop nose bleeding. Ambroise Paré (1510-1590) was an adversary of those practices.

  7. Helicopter thermal imaging for detecting insect infested cadavers.

    Science.gov (United States)

    Amendt, Jens; Rodner, Sandra; Schuch, Claus-Peter; Sprenger, Heinz; Weidlich, Lars; Reckel, Frank

    2017-09-01

    One of the most common techniques applied for searching living and even dead persons is the FLIR (Forward Looking Infrared) system fixed on an aircraft like e.g. a helicopter, visualizing the thermal patterns emitted from objects in the long-infrared spectrum. However, as body temperature cools down to ambient values within approximately 24h after death, it is common sense that searching for deceased persons can be just applied the first day post-mortem. We postulated that the insect larval masses on a decomposing body generate a heat which can be considerably higher than ambient temperatures for a period of several weeks and that such heat signatures might be used for locating insect infested human remains. We examined the thermal history of two 70 and 90kg heavy pig cadavers for 21days in May and June 2014 in Germany. Adult and immature insects on the carcasses were sampled daily. Temperatures were measured on and inside the cadavers, in selected maggot masses and at the surroundings. Thermal imaging from a helicopter using the FLIR system was performed at three different altitudes up to 1500ft. during seven day-flights and one night-flight. Insect colonization was dominated by blow flies (Diptera: Calliphoridae) which occurred almost immediately after placement of the cadavers. Larvae were noted first on day 2 and infestation of both cadavers was enormous with several thousand larvae each. After day 14 a first wave of post-feeding larvae left the carcasses for pupation. Body temperature of both cadavers ranged between 15°C and 35°C during the first two weeks of the experiment, while body surface temperatures peaked at about 45°C. Maggot masses temperatures reached values up to almost 25°C above ambient temperature. Detection of both cadavers by thermal imaging was possible on seven of the eight helicopter flights until day 21. Copyright © 2017 The Chartered Society of Forensic Sciences. Published by Elsevier B.V. All rights reserved.

  8. Measurement of the tendon of the biceps brachii after tenotomy: study on cadavers

    Directory of Open Access Journals (Sweden)

    Anderson Cunha Machado

    2015-08-01

    Full Text Available ABSTRACTOBJECTIVE: To evaluate the influence of elbow and forearm range of motion on the distal excursion of the long head of the biceps (LHB. METHODS: The distal excursion of the LHB after tenotomy of the shoulders of eight cadavers was ascertained by measuring the distance between a point marked out on the LHB, 3 cm from the anterolateral border of the acromion, and its position at different degrees of elbow flexion, using a digital pachymeter. The measurements at elbow flexion of 135°, 90°, 45° and 0° were noted: these angles were established using a goniometer. The measurements were made with the forearm in neutral, supination and pronation positions. RESULTS: Differences between the mean measurements of the distal excursion of the LHB (total sample were observed between the degrees of elbow flexion ( p< 0.01. However, no statistical differences were observed between the different forearm positions, between the sides, genders and ages of the cadavers studied. CONCLUSION: Progressive extension of the elbow caused progressive distal excursion of the LHB, but without interference in the forearm position, gender, side or age of the cadavers studied.

  9. Use of cadaver models in point-of-care emergency ultrasound education for diagnostic applications.

    Science.gov (United States)

    Zaia, Brita E; Briese, Beau; Williams, Sarah R; Gharahbaghian, Laleh

    2012-10-01

    As the use of bedside emergency ultrasound (US) increases, so does the need for effective US education. To determine 1) what pathology can be reliably simulated and identified by US in human cadavers, and 2) feasibility of using cadavers to improve the comfort of emergency medicine (EM) residents with specific US applications. This descriptive, cross-sectional survey study assessed utility of cadaver simulation to train EM residents in diagnostic US. First, the following pathologies were simulated in a cadaver: orbital foreign body (FB), retrobulbar (RB) hematoma, bone fracture, joint effusion, and pleural effusion. Second, we assessed residents' change in comfort level with US after using this cadaver model. Residents were surveyed regarding their comfort level with various US applications. After brief didactic sessions on the study's US applications, participants attempted to identify the simulated pathology using US. A post-lab survey assessed for change in comfort level after the training. Orbital FB, RB hematoma, bone fracture, joint effusion, and pleural effusion were readily modeled in a cadaver in ways typical of a live patient. Twenty-two residents completed the pre- and post-lab surveys. After training with cadavers, residents' comfort improved significantly for orbital FB and RB hematoma (mean increase 1.6, pcadavers helpful. Cadavers can simulate orbital FB, RB hematoma, bone fracture, joint effusion, and pleural effusion, and in our center improved the comfort of residents in identifying all but pleural effusion. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. 9 CFR 381.90 - Cadavers.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Cadavers. 381.90 Section 381.90 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY... § 381.90 Cadavers. Carcasses of poultry showing evidence of having died from causes other than slaughter...

  11. ORIGINAL ARTICLE: A New Embalming Fluid for Preserving Cadavers

    Directory of Open Access Journals (Sweden)

    P.E. Natekar

    2012-07-01

    Full Text Available Background: Dissection laboratory is the only place where the three dimensional structure of the human body is reinforced by visual, auditory and tactile pathways. Cadavers are main teaching tools in Anatomy and are handled by the staff and students routinely. Very often the cadavers enbalmed by various chemicals are not effective in inhibiting growth of fungi, bacteria, maggots etc. To date limited studies have been carried out to overcome this problem hence this study was undertaken to find out safe and effective enbalming fluid. Aims and Objectives: The main object of the present study is to provide a composition of body-preservation fluid which is effective in preventing decomposition of cadavers, maintaining a desired life-like appearance of the body which is non hazardous for dissection and environmentally safe. It was observed that chemical composition of the embalming fluid was very effective in prevention of growth of bacteria, fungus and also decay and discoloration. Results: This study was carried out in the department of Anatomy, Goa Medical College, Bambolim Goa (India from the year 2006 to 2011. Total 100 cadavers were embalmed with the following composition of the embalming fluid. It was observed that the solution in tanks where intact bodies were preserved was clear without any fungus form a period of 5 years whereas the dissected cadavers were kept separately also containing 10 percent formalin showed minimal growth of fungus after 12 months and the solution was replaced after 12 months. Conclusions: In our present study the tank containing undissected cadavers has not shown any growth of fungus for a period of 5 years. Routine dissected parts showed fungal growth only after 12 months, whereupon the scum was removed and the tank solution replaced. The arterial fluid was red in colour and could be differentiated from cavity fluid. The cadavers were free from growth of fungus and maggots during their entire first MBBS course. Not

  12. Relative device stability of anterior versus axillary needle decompression for tension pneumothorax during casualty movement: Preliminary analysis of a human cadaver model.

    Science.gov (United States)

    Leatherman, Matthew L; Held, Jenny M; Fluke, Laura M; McEvoy, Christian S; Inaba, Kenji; Grabo, Daniel; Martin, Matthew J; Earley, Angela S; Ricca, Robert L; Polk, Travis M

    2017-07-01

    Tension pneumothorax (tPTX) remains a significant cause of potentially preventable death in military and civilian settings. The current prehospital standard of care for tPTX is immediate decompression with a 14-gauge 8-cm angiocatheter; however, failure rates may be as high as 17% to 60%. Alternative devices, such as 10-gauge angiocatheter, modified Veress needle, and laparoscopic trocar, have shown to be potentially more effective in animal models; however, little is known about the relative insertional safety or mechanical stability during casualty movement. Seven soft-embalmed cadavers were intubated and mechanically ventilated. Chest wall thickness was measured at the second intercostal space at the midclavicular line (2MCL) and the fifth intercostal space along the anterior axillary line (5AAL). CO2 insufflation created a PTX, and needle decompression was then performed with a randomized device. Insertional depth was measured between hub and skin before and after simulated casualty transport. Thoracoscopy was used to evaluate for intrapleural placement and/or injury during insertion and after movement. Cadaver demographics, device displacement, device dislodgment, and injuries were recorded. Three decompressions were performed at each site (2MCL/5AAL), totaling 12 events per cadaver. Eighty-four decompressions were performed. Average cadaver age was 59 years, and body mass index was 24 kg/m. The CWT varied between cadavers because of subcutaneous emphysema, but the average was 39 mm at the 2MCL and 31 mm at the 5AAL. Following movement, the 2MCL site was more likely to become dislodged than the 5AAL (67% vs. 17%, p = 0.001). Median displacement also differed between 2MCL and 5AAL (23 vs. 2 mm, p = 0.001). No significant differences were noted in dislodgement or displacement between devices. Five minor lung injuries were noted at the 5AAL position. Preliminary results from this human cadaver study suggest the 5AAL position is a more stable and reliable location

  13. Measurement of electric intensity distribution inside a human cadaver cochlea for multichannel cochlear implants; Multichannel jinko naiji no tame no hito no tekishutsu kagyunai ni okeru denkai kyodo bunpu no sokutei

    Energy Technology Data Exchange (ETDEWEB)

    Miyoshi, S.; Ifukube, T.; Matsushima, J. [Hokkaido University, Sapporo (Japan)

    1998-03-01

    We have proposed a Tripolar Electrode Stimulation Method (TESM) which may succeed in narrowing the stimulation region and continuously moving the stimulation site for cochlear implants. The TESM stimulates the auditory nerve array through lymph liquid using the 3 adjacent electrodes which are selected among the electrodes of an electrode array. The currents from the two electrodes on both sides are emitted and a central electrode receives them. The current received by the central electrode is made equal to the sum of the currents emitted from the electrodes on both sides. In this paper, the electric intensity profiles produced by the TESM and the monopolar stimulation were measured in a human cadaver cochlea and in a saline solution. As a result, in the TESM, the electric intensity profile produced in the human cadaver cochlea was about the same as that in the saline solution In monopolar stimulation, the electric intensity profile was broader than that of TESM in a human cadaver cochlea. 9 refs., 14 figs.

  14. Comparison of Expandable and Fixed Interbody Cages in a Human Cadaver Corpectomy Model: Fatigue Characteristics.

    Science.gov (United States)

    Pekmezci, Murat; Tang, Jessica A; Cheng, Liu; Modak, Ashin; McClellan, Robert T; Buckley, Jenni M; Ames, Christopher P

    2016-11-01

    In vitro cadaver biomechanics study. The goal of this study is to compare the in situ fatigue life of expandable versus fixed interbody cage designs. Expandable cages are becoming more popular, in large part, due to their versatility; however, subsidence and catastrophic failure remain a concern. This in vitro analysis investigates the fatigue life of expandable and fixed interbody cages in a single level human cadaver corpectomy model by evaluating modes of subsidence of expandable and fixed cages as well as change in stiffness of the constructs with cyclic loading. Nineteen specimens from 10 human thoracolumbar spines (T10-L2, L3-L5) were biomechanically evaluated after a single level corpectomy that was reconstructed with an expandable or fixed cage and anterior dual rod instrumentation. All specimens underwent 98 K cycles to simulate 3 months of postoperative weight bearing. In addition, a third group with hyperlordotic cages was used to simulate catastrophic failure that is observed in clinical practice. Three fixed and 2 expandable cages withstood the cyclic loading despite perfect sagittal and coronal plane fitting of the endcaps. The majority of the constructs settled in after initial subsidence. The catastrophic failures that were observed in clinical practice could not be reproduced with hyperlordotic cages. However, all cages in this group subsided, and 60% resulted in endplate fractures during deployment of the cage. Despite greater surface contact area, expandable cages have a trend for higher subsidence rates when compared with fixed cages. When there is edge loading as in the hyperlordotic cage scenario, there is a higher risk of subsidence and intraoperative fracture during deployment of expandable cages.

  15. Harmonic scalpel versus flexible CO2 laser for tongue resection: A histopathological analysis of thermal damage in human cadavers

    Directory of Open Access Journals (Sweden)

    Wolf Tamir

    2011-08-01

    Full Text Available Abstract Background Monopolar cautery is the most commonly used surgical cutting and hemostatic tool for head and neck surgery. There are newer technologies that are being utilized with the goal of precise cutting, decreasing blood loss, reducing thermal damage, and allowing faster wound healing. Our study compares thermal damage caused by Harmonic scalpel and CO2 laser to cadaveric tongue. Methods Two fresh human cadaver heads were enrolled for the study. Oral tongue was exposed and incisions were made in the tongue akin to a tongue tumor resection using the harmonic scalpel and flexible C02 laser fiber at various settings recommended for surgery. The margins of resection were sampled, labeled, and sent for pathological analysis to assess depth of thermal damage calculated in millimeters. The pathologist was blinded to the surgical tool used. Control tongue tissue was also sent for comparison as a baseline for comparison. Results Three tongue samples were studied to assess depth of thermal damage by harmonic scalpel. The mean depth of thermal damage was 0.69 (range, 0.51 - 0.82. Five tongue samples were studied to assess depth of thermal damage by CO2 laser. The mean depth of thermal damage was 0.3 (range, 0.22 to 0.43. As expected, control samples showed 0 mm of thermal damage. There was a statistically significant difference between the depth of thermal injury to tongue resection margins by harmonic scalpel as compared to CO2 laser, (p = 0.003. Conclusion In a cadaveric model, flexible CO2 laser fiber causes less depth of thermal damage when compared with harmonic scalpel at settings utilized in our study. However, the relevance of this information in terms of wound healing, hemostasis, safety, cost-effectiveness, and surgical outcomes needs to be further studied in clinical settings.

  16. Insect cadaver applications: pros and cons

    Science.gov (United States)

    Application of entomopathogenic nematodes (EPNs) formulated as insect cadavers has become an alternative to aqueous application for the control of agricultural pests. In this approach, the infected insect host cadaver is applied directly to the target site and pest suppression is achieved by the inf...

  17. Fresh frozen cadaver workshops for advanced vascular surgical training.

    Science.gov (United States)

    Jansen, Shirley; Cowie, Margaret; Linehan, John; Hamdorf, Jeffery M

    2014-11-01

    Reduction in working hours, streamlined training schemes and increasing use of endovascular techniques has meant a reduction in operative experience for newer vascular surgical trainees, especially those exposures which are not routinely performed such as thoracoabdominal, thoracotomy and retroperitoneal aortic, for example. This paper describes an Advanced Anatomy of Exposure course which was designed and convened at the Clinical Training & Evaluation Centre in Western Australia and uses fresh frozen cadavers. Feedback was obtained from the participants who attended over three courses by questionnaire. Feedback was strongly positive for the course meeting both its learning outcomes and personal learning objectives, and in addition, making a significant contribution to specialty skills. Most participants thought the fresh frozen cadaveric model significantly improved the learning objectives for training. The fresh frozen cadaver is an excellent teaching model highly representative of the living open surgical scenario where advanced trainees and newly qualified consultants can improve their operative confidence and consequently patient safety in vascular surgery. An efficient fresh frozen cadaver teaching programme can benefit many health professionals simultaneously maximizing the use of donated human tissue. © 2013 Royal Australasian College of Surgeons.

  18. Development, Validation and Parametric study of a 3-Year-Old Child Head Finite Element Model

    Science.gov (United States)

    Cui, Shihai; Chen, Yue; Li, Haiyan; Ruan, ShiJie

    2015-12-01

    Traumatic brain injury caused by drop and traffic accidents is an important reason for children's death and disability. Recently, the computer finite element (FE) head model has been developed to investigate brain injury mechanism and biomechanical responses. Based on CT data of a healthy 3-year-old child head, the FE head model with detailed anatomical structure was developed. The deep brain structures such as white matter, gray matter, cerebral ventricle, hippocampus, were firstly created in this FE model. The FE model was validated by comparing the simulation results with that of cadaver experiments based on reconstructing the child and adult cadaver experiments. In addition, the effects of skull stiffness on the child head dynamic responses were further investigated. All the simulation results confirmed the good biofidelity of the FE model.

  19. Near-Infrared Confocal Laser Reflectance Cytoarchitectural Imaging of the Substantia Nigra and Cerebellum in the Fresh Human Cadaver.

    Science.gov (United States)

    Cheyuo, Cletus; Grand, Walter; Balos, Lucia L

    2017-01-01

    Cytoarchitectural neuroimaging remains critical for diagnosis of many brain diseases. Fluorescent dye-enhanced, near-infrared confocal in situ cellular imaging of the brain has been reported. However, impermeability of the blood-brain barrier to most fluorescent dyes limits clinical utility of this modality. The differential degree of reflectance from brain tissue with unenhanced near-infrared imaging may represent an alternative technique for in situ cytoarchitectural neuroimaging. We assessed the utility of unenhanced near-infrared confocal laser reflectance imaging of the cytoarchitecture of the cerebellum and substantia nigra in 2 fresh human cadaver brains using a confocal near-infrared laser probe. Cellular images based on near-infrared differential reflectance were captured at depths of 20-180 μm from the brain surface. Parts of the cerebellum and substantia nigra imaged using the probe were subsequently excised and stained with hematoxylin and eosin for histologic correlation. Near-infrared reflectance imaging revealed the 3-layered cytoarchitecture of the cerebellum, with Purkinje cells appearing hyperreflectant. In the substantia nigra, neurons appeared hyporeflectant with hyperreflectant neuromelanin cytoplasmic inclusions. Cytoarchitecture of the cerebellum and substantia nigra revealed on near-infrared imaging closely correlated with the histology on hematoxylin-eosin staining. We showed that unenhanced near-infrared reflectance imaging of fresh human cadaver brain can reliably identify and distinguish neurons and detailed cytoarchitecture of the cerebellum and substantia nigra. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Laxity of the elbow after experimental excision of the radial head and division of the medial collateral ligament. Efficacy of ligament repair and radial head prosthetic replacement

    DEFF Research Database (Denmark)

    Jensen, S.L.; Deutch, S.R.; Olsen, B.S.

    2003-01-01

    We studied the stabilising effect of prosthetic replacement of the radial head and repair of the medial collateral ligament (MCL) after excision of the radial head and section of the MCL in five cadaver elbows. Division of the MCL increased valgus angulation (mean 3.9 +/- 1.5 degrees) and internal...

  1. Analysis of Dual Mobility Liner Rim Damage Using Retrieved Components and Cadaver Models.

    Science.gov (United States)

    Nebergall, Audrey K; Freiberg, Andrew A; Greene, Meridith E; Malchau, Henrik; Muratoglu, Orhun; Rowell, Shannon; Zumbrunn, Thomas; Varadarajan, Kartik M

    2016-07-01

    The objective of this study was to assess the retentive rim of retrieved dual mobility liners for visible evidence of deformation from femoral neck contact and to use cadaver models to determine if anterior soft tissue impingement could contribute to such deformation. Fifteen surgically retrieved polyethylene liners were assessed for evidence of rim deformation. The average time in vivo was 31.4 months, and all patients were revised for reasons other than intraprosthetic dislocation. Liner interaction with the iliopsoas was studied visually and with fluoroscopy in cadaver specimens using a dual mobility system different than the retrieval study. For fluoroscopic visualization, a metal wire was sutured to the iliopsoas and wires were also embedded into grooves on the outer surface of the liner and the inner head. All retrievals showed evidence of femoral neck contact. The cadaver experiments showed that liner motion was impeded by impingement with the iliopsoas tendon in low flexion angles. When observing the hip during maximum hyperextension, 0°, 15°, and 30° of flexion, there was noticeable tenting of the iliopsoas caused by impingement with the liner. Liner rim deformation resulting from contact with the femoral neck likely begins during early in vivo function. The presence of deformation is indicative of a mechanism inhibiting mobility of the liner. The cadaver studies showed that liner motion could be impeded because of its impingement with the iliopsoas. Such soft tissue impingement may be one mechanism by which liner motion is routinely inhibited, which can result in load transfer from the neck to the rim. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. A Randomized Cadaver Study Comparing First-Attempt Success Between Tibial and Humeral Intraosseous Insertions Using NIO Device by Paramedics: A Preliminary Investigation.

    Science.gov (United States)

    Szarpak, Lukasz; Truszewski, Zenon; Smereka, Jacek; Krajewski, Paweł; Fudalej, Marcin; Adamczyk, Piotr; Czyzewski, Lukasz

    2016-05-01

    Medical personnel may encounter difficulties in obtaining intravenous (IV) access during cardiac arrest. The 2015 American Heart Association guidelines and the 2015 European Resuscitation Council guidelines for cardiopulmonary resuscitation (CPR) suggest that rescuers establish intraosseous (IO) access if an IV line is not easily obtainable.The aim of the study was to compare the success rates of the IO proximal tibia and proximal humerus head access performed by paramedics using the New Intraosseous access device (NIO; Persys Medical, Houston, TX, USA) in an adult cadaver model during simulated CPR.In an interventional, randomized, crossover, single-center cadaver study, a semi-automatic spring-load driven NIO access device was investigated. In total, 84 paramedics with less than 5-year experience in Emergency Medical Service participated in the study. The trial was performed on 42 adult cadavers. In each cadaver, 2 IO accesses to the humerus head, and 2 IO accesses to the proximal tibia were obtained.The success rate of the first IO attempt was 89.3% (75/84) for tibial access, and 73.8% (62/84) for humeral access (P = 0.017). The procedure times were significantly faster for tibial access [16.8 (interquartile range, IQR, 15.1-19.9] s] than humeral access [26.7 (IQR, 22.1-30.9) s] (P < 0.001).Tibial IO access is easier and faster to put in place than humeral IO access. Humeral IO access can be an alternative method to tibial IO access. clinicaltrials.gov Identifier: NCT02700867.

  3. Supernumerary head of biceps brachii and branching pattern of the musculocutaneous nerve

    Directory of Open Access Journals (Sweden)

    Mohan Basavaraj Angadi

    2016-01-01

    Full Text Available During routine dissection by medical undergraduates, third head of the biceps brachii muscle was found on the left side of a 75-year-old male cadaver in a total of 48 arms dissected in Department of Anatomy Armed Forces Medical College, Pune. Biceps brachii is a muscle of arm having two heads hence the name. The most frequent variation of the muscle is in the number of heads with a prevalence range of 9.1-22.9%. The origin of the supernumerary head in this case was from the humerus, between the insertion of the coracobrachialis and the upper part of the origin of the brachialis, and also from the medial intermuscular septum. The supernumerary head joined the common belly. It was supplied by the musculocutaneous nerve which after emerging from brachialis pierced it near the middle and terminated by finally supplying the biceps belly. In our study, 2.08% (1 of 48 of male cadavers were found to have the third head of biceps. The incidence of this variation can be as much as 10% as, shown in previous studies on Indian population, as reported in standard textbooks of anatomy.

  4. Perception of Surgical Faculty on the Utility of Modified Thiel Embalmed Cadavers

    Directory of Open Access Journals (Sweden)

    Ashwini C Appaji

    2017-10-01

    Full Text Available Introduction: Surgical skills training on low and high fidelity simulators have been in practice for over a decade, but due to the high cost of virtual reality simulators it is beyond the reach of institutions and trainees. Among the simulators, high fidelity simulators such as a suitably prepared human anatomical specimen would give a real feel as if doing the procedure in the living. Hence, having soft, supple cadaver with organoleptic properties is an ideal situation for training by simulation and research. To facilitate the surgical skill training and research, chemical embalming was adopted with modifications of the Thiel method, for cadaver preservation. Aim: The aim of this study was to study the perception of the surgical faculty’s experience on the utility of modified Thiel embalmed cadavers for surgical procedures. Materials and Methods: In this cross-sectional study, a feedback was taken from practicing surgeons of broad and sub specialties such as general surgery, orthopedic surgery, neurosurgery, plastic surgery, pediatric surgery, ophthalmology, ENT, OBG, Transplant surgery (n=54. A 5 point Likert scale questionnaire was used with criteria of measurements like skin color, consistency, odour, differentiation of the layers, approach to the area, joint mobility and suitability for the procedure. Results: The scores ranged from 3.9 to 4.46/5. The participants expressed satisfaction on the cadaver quality on their utility for performance of surgical procedures. They expressed that, such embalmed cadavers would be excellent for learning purpose, surgical skills training in orthopedic procedures like arthroscopy. They felt the joint mobility was good, the consistency was soft and differentiation of layers was good. Some felt the tissues were fragile and would easily give away losing their strength. Conclusion: Thiel embalmed cadavers retain their organoleptic properties and hence facilitate surgical skills training. The thiel embalmed

  5. Pullout strength of bone-patellar tendon-bone allograft bone plugs: a comparison of cadaver tibia and rigid polyurethane foam.

    Science.gov (United States)

    Barber, F Alan

    2013-09-01

    To compare the load-to-failure pullout strength of bone-patellar tendon-bone (BPTB) allografts in human cadaver tibias and rigid polyurethane foam blocks. Twenty BPTB allografts were trimmed creating 25 mm × 10 mm × 10 mm tibial plugs. Ten-millimeter tunnels were drilled in 10 human cadaver tibias and 10 rigid polyurethane foam blocks. The BPTB anterior cruciate ligament allografts were inserted into these tunnels and secured with metal interference screws, with placement of 10 of each type in each material. After preloading (10 N), cyclic loading (500 cycles, 10 to 150 N at 200 mm/min) and load-to-failure testing (200 mm/min) were performed. The endpoints were ultimate failure load, cyclic loading elongation, and failure mode. No difference in ultimate failure load existed between grafts inserted into rigid polyurethane foam blocks (705 N) and those in cadaver tibias (669 N) (P = .69). The mean rigid polyurethane foam block elongation (0.211 mm) was less than that in tibial bone (0.470 mm) (P = .038), with a smaller standard deviation (0.07 mm for foam) than tibial bone (0.34 mm). All BPTB grafts successfully completed 500 cycles. The rigid polyurethane foam block showed less variation in test results than human cadaver tibias. Rigid polyurethane foam blocks provide an acceptable substitute for human cadaver bone tibia for biomechanical testing of BPTB allografts and offer near-equivalent results. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Review of forensically important entomological specimens collected from human cadavers in Malaysia (2005-2010).

    Science.gov (United States)

    Kavitha, Rajagopal; Nazni, Wasi Ahmad; Tan, Tian Chye; Lee, Han Lim; Azirun, Mohd Sofian

    2013-07-01

    Forensic entomological specimens collected from human decedents during crime scene investigations in Malaysia in the past 6 years (2005-2010) are reviewed. A total of 80 cases were recorded and 93 specimens were collected. From these specimens, 10 species of cyclorrphagic flies were identified, consisting of Chrysomya rufifacies (Macquart) -38 specimens (40.86%), Chrysomya megacephala (Fabricius) -36 specimens (38.70%), Chrysomya villeneuvi (Patton) -2 specimens (2.15%), Chrysomya nigripes (Aubertin) -2 specimens (2.15%), Chrysomya pinguis (Walker) -1 specimen (1.08%), Hermetia illucens (Linnaeus) -1 specimen (1.08%), Hemipyrellia liguriens (Wiedemann) -5 specimens (5.37%), Synthesiomyia nudiseta (Wulp) -1 specimen (1.08%), Megaselia scalaris (Loew)-1 specimen (1.08%) and Sarcophaga ruficornis (Fabricius) -4 specimens (4.30%). In two specimens (2.15%), the maggots were not identifiable. Ch. megacephala and Ch. rufifacies were the commonest species found in human decedents from three different ecological habitats. S. nudiseta is an uncommon species found only on human cadavers from indoors. A total of 75 cases (93.75%) had a single fly infestation and 5 cases (6.25%) had double fly infestation. In conclusion, although large numbers of fly species were found on human decedents, the predominant species are still those of Chrysomya. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  7. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures.

    Science.gov (United States)

    Basso, Trude; Klaksvik, Jomar; Syversen, Unni; Foss, Olav A

    2014-12-18

    Fourth generation composite femurs (4GCFs, models #3406 and #3403) simulate femurs of males cadaver femurs (HCFs) selected to represent patients with hip fractures. Ten 4GCFs (Sawbones, Pacific Research Laboratories, Inc., Vashon, WA, USA) were compared to 24 HCFs from seven females and five males >60 years. Proximal femur anthropometric measurements were noted. Strain gauge rosettes were attached and femurs were mounted in a hip simulator applying a combined subject-specific axial load and torque. Baseline measurements of resistance to deformation were recorded. Standardized femoral neck fractures were surgically stabilized before the constructs were subjected to 20,000 load-cycles. An optical motion tracking system measured relative movements. Median (95% CI) head fragment migration was 0.8mm (0.4 to 1.1) in the 4GCF group versus 2.2mm (1.5 to 4.6) in the cadaver group (p=0.001). This difference in fracture stability could not be explained by observed differences in femoral anthropometry or potential overloading of 4GCFs. 4GCFs failed with fracture-patterns different from those observed in cadavers. To conclude, standard 4GCFs provide unrealistically stable bone-implant constructs and fail with fractures not observed in cadavers. Until a validated osteopenic or osteoporotic composite femur model is provided, standard 4GCFs should only be used when representing the biomechanical properties of young healthy femurs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    International Nuclear Information System (INIS)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M

    2016-01-01

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  9. SU-F-I-46: Optimizing Dose Reduction in Adult Head CT Protocols While Maintaining Image Quality in Postmortem Head Scans

    Energy Technology Data Exchange (ETDEWEB)

    Lipnharski, I; Carranza, C; Quails, N; Correa, N; Rajderkar, D; Bennett, J; Rill, L; Arreola, M [University of Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: To optimize adult head CT protocol by reducing dose to an appropriate level while providing CT images of diagnostic quality. Methods: Five cadavers were scanned from the skull base to the vertex using a routine adult head CT protocol (120 kVp, 270 mA, 0.75 s rotation, 0.5 mm × 32 detectors, 70.8 mGy CTDIvol) followed by seven reduced-dose protocols with varying combinations of reduced tube current, reduced rotation time, and increased detectors with CTDIvol ranging from 38.2 to 65.6 mGy. Organ doses were directly measured with 21 OSL dosimeters placed on the surface and implanted in the head by a neurosurgeon. Two neuroradiologists assessed grey-white matter differentiation, fluid space, ventricular size, midline shift, brain mass, edema, ischemia, and skull fractures on a three point scale: (1) Unacceptable, (2) Borderline Acceptable, and (3) Acceptable. Results: For the standard scan, doses to the skin, lens of the eye, salivary glands, thyroid, and brain were 37.55 mGy, 49.65 mGy, 40.67 mGy, 4.63 mGy, and 27.33 mGy, respectively. Two cadavers had cerebral edema due to changing dynamics of postmortem effects, causing the grey-white matter differentiation to appear less distinct. Two cadavers with preserved grey-white matter received acceptable scores for all image quality features for the protocol with a CTDIvol of 57.3 mGy, allowing organ dose savings ranging from 34% to 45%. One cadaver allowed for greater dose reduction for the protocol with a CTDIvol of 42 mGy. Conclusion: Efforts to optimize scan protocol should consider both dose and clinical image quality. This is made possible with postmortem subjects, whose brains are similar to patients, allowing for an investigation of ideal scan parameters. Radiologists at our institution accepted scan protocols acquired with lower scan parameters, with CTDIvol values closer to the American College of Radiology’s (ACR) Achievable Dose level of 57 mGy.

  10. Upper and Lower Limb Muscle Architecture of a 104 Year-Old Cadaver.

    Science.gov (United States)

    Ruggiero, Marissa; Cless, Daniel; Infantolino, Benjamin

    2016-01-01

    Muscle architecture is an important component to typical musculoskeletal models. Previous studies of human muscle architecture have focused on a single joint, two adjacent joints, or an entire limb. To date, no study has presented muscle architecture for the upper and lower limbs of a single cadaver. Additionally, muscle architectural parameters from elderly cadavers are lacking, making it difficult to accurately model elderly populations. Therefore, the purpose of this study was to present muscle architecture of the upper and lower limbs of a 104 year old female cadaver. The major muscles of the upper and lower limbs were removed and the musculotendon mass, tendon mass, musculotendon length, tendon length, pennation angle, optimal fascicle length, physiological cross-sectional area, and tendon cross-sectional area were determined for each muscle. Data from this complete cadaver are presented in table format. The data from this study can be used to construct a musculoskeletal model of a specific individual who was ambulatory, something which has not been possible to date. This should increase the accuracy of the model output as the model will be representing a specific individual, not a synthesis of measurements from multiple individuals. Additionally, an elderly individual can be modeled which will provide insight into muscle function as we age.

  11. Human cadaver multipotent stromal/stem cells isolated from arteries stored in liquid nitrogen for 5 years

    Science.gov (United States)

    2014-01-01

    Introduction Regenerative medicine challenges researchers to find noncontroversial, safe and abundant stem cell sources. In this context, harvesting from asystolic donors could represent an innovative and unlimited reservoir of different stem cells. In this study, cadaveric vascular tissues were established as an alternative source of human cadaver mesenchymal stromal/stem cells (hC-MSCs). We reported the successful cell isolation from postmortem arterial segments stored in a tissue-banking facility for at least 5 years. Methods After thawing, hC-MSCs were isolated with a high efficiency (12 × 106) and characterized with flow cytometry, immunofluorescence, molecular and ultrastructural approaches. Results In early passages, hC-MSCs were clonogenic, highly proliferative and expressed mesenchymal (CD44, CD73, CD90, CD105, HLA-G), stemness (Stro-1, Oct-4, Notch-1), pericyte (CD146, PDGFR-β, NG2) and neuronal (Nestin) markers; hematopoietic and vascular markers were negative. These cells had colony and spheroid-forming abilities, multipotency for their potential to differentiate in multiple mesengenic lineages and immunosuppressive activity to counteract proliferation of phytohemagglutinin-stimulated blood mononuclear cells. Conclusions The efficient procurement of stem cells from cadaveric sources, as postmortem vascular tissues, demonstrates that such cells can survive to prolonged ischemic insult, anoxia, freezing and dehydration injuries, thus paving the way for a scientific revolution where cadaver stromal/stem cells could effectively treat patients demanding cell therapies. PMID:24429026

  12. Self-Reported Emergency Medicine Residency Applicant Attitudes Towards a Procedural Cadaver Laboratory Curriculum

    Directory of Open Access Journals (Sweden)

    Hoffman, Lance

    2008-08-01

    Full Text Available OBJECTIVE: Residency applicants consider a variety of factors when ranking emergency medicine (EM programs for their NRMP match list. A human cadaver emergency procedure lab curriculum is uncommon. We hypothesized that the presence this curriculum would positively impact the ranking of an EM residency program.METHODS: The EM residency at Nebraska Medical Center is an urban, university-based program with a PGY I-III format. Residency applicants during the interview for a position in the PGY I class of 2006 were surveyed by three weekly electronic mailings. The survey was distributed in March 2006 after the final NRMP match results were released. The survey explored learner preferences and methodological commonality of models of emergency procedural training, as well as the impact of a procedural cadaver lab curriculum on residency ranking. ANOVA of ranks was used to compare responses to ranking questions.RESULTS: Of the 73 potential subjects, 54 (74% completed the survey. Respondents ranked methods of procedural instruction from 1 (most preferred or most common technique to 4 (least preferred or least common technique. Response averages and 95% confidence intervals for the preferred means of learning a new procedure are as follows: textbook (3.69; 3.51-3.87, mannequin (2.83; 2.64-3.02, human cadaver (1.93; 1.72-2.14, and living patient (1.56; 1.33-1.79. Response averages for the commonality of means used to teach a new procedure are as follows: human cadaver (3.63; 3.46-3.80, mannequin (2.70; 2.50-2.90, living patient (2.09; 1.85-2.33, and textbook (1.57; 1.32-1.82. When asked if the University of Nebraska Medical Center residency ranked higher in the individual's match list because of its procedural cadaver lab, 14.8% strongly disagreed, 14.8% disagreed, 40.7% were neutral, 14.8% agreed, and 14.8% strongly agreed.CONCLUSION: We conclude that, although cadaveric procedural training is viewed by senior medical student learners as a desirable means

  13. Effect of wrist and interphalangeal thumb movement on zone T2 flexor pollicis longus tendon tension in a human cadaver model.

    Science.gov (United States)

    Rappaport, Patricia O; Thoreson, Andrew R; Yang, Tai-Hua; Reisdorf, Ramona L; Rappaport, Stephen M; An, Kai-Nan; Amadio, Peter C

    2015-01-01

    Therapy after flexor pollicis longus (FPL) repair typically mimics finger flexor management, but this ignores anatomic and biomechanical features unique to the FPL. We measured FPL tendon tension in zone T2 to identify biomechanically appropriate exercises for mobilizing the FPL. Eight human cadaver hands were studied to identify motions that generated enough force to achieve FPL movement without exceeding hypothetical suture strength. With the carpometacarpal and metacarpophalangeal joints blocked, appropriate forces were produced for both passive interphalangeal (IP) motion with 30° wrist extension and simulated active IP flexion from 0° to 35° with the wrist in the neutral position. This work provides a biomechanical basis for safely and effectively mobilizing the zone T2 FPL tendon. Our cadaver study suggests that it is safe and effective to perform early passive and active exercise to an isolated IP joint. NA. Copyright © 2015 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  14. Saturated salt solution method: a useful cadaver embalming for surgical skills training.

    Science.gov (United States)

    Hayashi, Shogo; Homma, Hiroshi; Naito, Munekazu; Oda, Jun; Nishiyama, Takahisa; Kawamoto, Atsuo; Kawata, Shinichi; Sato, Norio; Fukuhara, Tomomi; Taguchi, Hirokazu; Mashiko, Kazuki; Azuhata, Takeo; Ito, Masayuki; Kawai, Kentaro; Suzuki, Tomoya; Nishizawa, Yuji; Araki, Jun; Matsuno, Naoto; Shirai, Takayuki; Qu, Ning; Hatayama, Naoyuki; Hirai, Shuichi; Fukui, Hidekimi; Ohseto, Kiyoshige; Yukioka, Tetsuo; Itoh, Masahiro

    2014-12-01

    This article evaluates the suitability of cadavers embalmed by the saturated salt solution (SSS) method for surgical skills training (SST). SST courses using cadavers have been performed to advance a surgeon's techniques without any risk to patients. One important factor for improving SST is the suitability of specimens, which depends on the embalming method. In addition, the infectious risk and cost involved in using cadavers are problems that need to be solved. Six cadavers were embalmed by 3 methods: formalin solution, Thiel solution (TS), and SSS methods. Bacterial and fungal culture tests and measurement of ranges of motion were conducted for each cadaver. Fourteen surgeons evaluated the 3 embalming methods and 9 SST instructors (7 trauma surgeons and 2 orthopedists) operated the cadavers by 21 procedures. In addition, ultrasonography, central venous catheterization, and incision with cauterization followed by autosuture stapling were performed in some cadavers. The SSS method had a sufficient antibiotic effect and produced cadavers with flexible joints and a high tissue quality suitable for SST. The surgeons evaluated the cadavers embalmed by the SSS method to be highly equal to those embalmed by the TS method. Ultrasound images were clear in the cadavers embalmed by both the methods. Central venous catheterization could be performed in a cadaver embalmed by the SSS method and then be affirmed by x-ray. Lungs and intestines could be incised with cauterization and autosuture stapling in the cadavers embalmed by TS and SSS methods. Cadavers embalmed by the SSS method are sufficiently useful for SST. This method is simple, carries a low infectious risk, and is relatively of low cost, enabling a wider use of cadavers for SST.

  15. A novel cadaver-based educational program in general surgery training.

    Science.gov (United States)

    Lewis, Catherine E; Peacock, Warwick J; Tillou, Areti; Hines, O Joe; Hiatt, Jonathan R

    2012-01-01

    To describe the development of a cadaver-based educational program and report our residents' assessment of the new program. An anatomy-based educational program was developed using fresh frozen cadavers to teach surgical anatomy and operative skills to general surgery (GS) trainees. Residents were asked to complete a voluntary, anonymous survey evaluating perceptions of the program (6 questions formulated on a 5-point Likert scale) and comparing cadaver sessions to other types of learning (4 rank order questions). Large university teaching hospital. Medical students, residents, and faculty members were participants in the cadaver programs. Only GS residents were asked to complete the survey. Since its implementation, 150 residents of all levels participated in 13 sessions. A total of 40 surveys were returned for a response rate of 89%. Overall, respondents held a positive view of the cadaver sessions and believed them to be useful for learning anatomy (94% agree or strongly agree), learning the steps of an operation (76% agree or strongly agree), and increasing confidence in doing an operation (53% agree or strongly agree). Trainees wanted to have more sessions (87% agree or strongly agree), and believed they would spend free time in the cadaver laboratory (58% agree or strongly agree). Compared with other learning modalities, cadaver sessions were ranked first for learning surgical anatomy, followed by textbooks, simulators, web sites, animate laboratories, and lectures. Respondents also ranked cadaver sessions first for increasing confidence in performing a procedure and for learning the steps of an operation. Cost of cadavers represented the major expense of the program. Fresh cadaver dissections represent a solution to the challenges of efficient, safe, and effective general surgery education. Residents have a positive attitude toward these teaching sessions and found them to be more effective than other learning modalities. Copyright © 2012 Association of

  16. Fish as aquatic “sniffer dogs”: Olfactory-mediated behaviors and conditioning of common carps to cadaver odors

    Directory of Open Access Journals (Sweden)

    Brian Wade Jamandre

    2015-12-01

    Full Text Available Even with the aide of modern technology, the search for cadaver or human remains underwater is still assisted by sniffer dogs mainly because of their superior sense of olfaction. However, dogs rely on volatile organic compounds in the air and that this may constraint their ability when searching for submerged cadavers. On the other hand, it has long been recognized that fishes use olfaction to sample odors from their surroundings to accomplish a task and are capable of acquiring new skills through training or conditioning. Despite decades of experimental and observational studies of the olfactory sensitivities of fishes, its potential application to forensic sciences has never been truly explored. In this pioneering research, we explore the possibility of using fish olfaction in detecting cadaver odors (porcine origin, using common carps Cyprinus carpio as model species in a series of experiments under laboratory conditions. We first observed the innate behavior of carps towards cadaver odors. Afterwards, the carps were trained in two-choice chamber experimental tanks by appetitive olfactory conditioning and odor masking methods. We also experimented on the effects of cadaver odors by early exposure using eggs and larval impregnation techniques, and observing the behaviors when they develop to early juveniles. In general, we found out that common carps are naturally repelled to cadaver odors. However using our devised conditioning protocol, results show that the conditioned carps were able to learn to be attracted to cadaver odors despite their innate aversion. The development of fish for cadaver detection is a simple but innovative idea and that it may present a cost-effective and reliable solution for the shortcomings of the existing methods in underwater cadaver search. We anticipate that this research will open up a variety of different studies in pursuit of developing fishes as biosensors and its application to forensic sciences.

  17. Anatomic study of celiac ganglia using CT in cadavers

    International Nuclear Information System (INIS)

    Zhao Qionghui; Zhang Xiaoming; Zeng Nanlin; Cai Changping; Xie Xingguo; Li Chengjun

    2005-01-01

    Objective: To identify the celiac ganglia in cadavers by using current CT techniques, and to facilitate its identification in vivo by CT. Methods: Fifty cadavers were dissected, moving peritoneal organs such as liver and stomach to expose the celiac ganglia. The location, morphology, and dimensions of celiac ganglia, and their relationship to abutting structures, were noted. The celiac ganglia in 6 of the 50 cadavers without peripancreatic diseases and with clear anatomy were isolated and marked with yellow dye and Iohexol injection. In these 6 cadavers, the moved organs were relocated, the abdomen was closed, and CT was performed. CT derived measurements of celiac ganglia were compared with those from cadavers study. Results: The celiac ganglia of 47 of 50 cadavers (94%) were located between T12-L1, and those of 3 cadavers (6%) were located between T11-12. The superior-inferior diameter of the right ganglia was (25.01 ±6.09) mm, long (left-right) diameter was (13.18 ± 3.62) mm, and short (thickness) diameter was (1.40 ± 0.55) mm. In the left ganglia, these three diameters were (22.74 ± 5.70) mm, (15.07 ± 4.35) mm, and (2.00 ± 0.71 ) mm, respectively. On the CT images of 6 cadavers, the right and left ganglia were all identified and were hyperdense relative to viscus, such as liver and spleen. The long and short diameters on CT images were (15.20 ± 1.64) mm and (1.53 ± 0.52) mm for the right ganglia and (16.25 ± 1.73 ) mm and (2.20 ± 0.73) mm for the left ganglia. There was no significant difference between the diameters of the ganglia measured on CT images and by dissection (P>0.05). Conclusion: Current CT techniques can demonstrate accurately the celiac ganglia in cadavers. This can be a reference for identifying the celiac plexus in vivo. (authors)

  18. Cadaver Thanatomicrobiome Signatures: The Ubiquitous Nature of Clostridium Species in Human Decomposition

    Directory of Open Access Journals (Sweden)

    Gulnaz T. Javan

    2017-10-01

    Full Text Available Human thanatomicrobiome studies have established that an abundant number of putrefactive bacteria within internal organs of decaying bodies are obligate anaerobes, Clostridium spp. These microorganisms have been implicated as etiological agents in potentially life-threatening infections; notwithstanding, the scale and trajectory of these microbes after death have not been elucidated. We performed phylogenetic surveys of thanatomicrobiome signatures of cadavers’ internal organs to compare the microbial diversity between the 16S rRNA gene V4 hypervariable region and V3-4 conjoined regions from livers and spleens of 45 cadavers undergoing forensic microbiological studies. Phylogenetic analyses of 16S rRNA gene sequences revealed that the V4 region had a significantly higher mean Chao1 richness within the total microbiome data. Permutational multivariate analysis of variance statistical tests, based on unweighted UniFrac distances, demonstrated that taxa compositions were significantly different between V4 and V3-4 hypervariable regions (p < 0.001. Of note, we present the first study, using the largest cohort of criminal cases to date, that two hypervariable regions show discriminatory power for human postmortem microbial diversity. In conclusion, here we propose the impact of hypervariable region selection for the 16S rRNA gene in differentiating thanatomicrobiomic profiles to provide empirical data to explain a unique concept, the Postmortem Clostridium Effect.

  19. Spread of Injectate Around Hip Articular Sensory Branches of the Femoral Nerve in Cadavers

    DEFF Research Database (Denmark)

    Nielsen, Niels Dalsgaard; Greher, Manfred; Moriggl, Bernhard

    2018-01-01

    of the femoral nerve. Methods: Fifteen cadaver sides were injected with 5 mL dye in the iliopsoas plane guided by ultrasound. Dissection was performed to verify the spread of injectate around the hip articular branches of the femoral nerve. Results: In 10 dissections (67% [95% confidence interval: 38.......2-32%]) adhesions partially obstructed the spread of dye. Conclusion: An injection of 5 mL in the iliopsoas plane spreads around all hip articular branches of the femoral nerve in 10 of 15 cadaver sides. If these findings translate to living humans, injection of local anaesthetic into the iliopsoas plane could...

  20. Systematic biases in human heading estimation.

    Directory of Open Access Journals (Sweden)

    Luigi F Cuturi

    Full Text Available Heading estimation is vital to everyday navigation and locomotion. Despite extensive behavioral and physiological research on both visual and vestibular heading estimation over more than two decades, the accuracy of heading estimation has not yet been systematically evaluated. Therefore human visual and vestibular heading estimation was assessed in the horizontal plane using a motion platform and stereo visual display. Heading angle was overestimated during forward movements and underestimated during backward movements in response to both visual and vestibular stimuli, indicating an overall multimodal bias toward lateral directions. Lateral biases are consistent with the overrepresentation of lateral preferred directions observed in neural populations that carry visual and vestibular heading information, including MSTd and otolith afferent populations. Due to this overrepresentation, population vector decoding yields patterns of bias remarkably similar to those observed behaviorally. Lateral biases are inconsistent with standard bayesian accounts which predict that estimates should be biased toward the most common straight forward heading direction. Nevertheless, lateral biases may be functionally relevant. They effectively constitute a perceptual scale expansion around straight ahead which could allow for more precise estimation and provide a high gain feedback signal to facilitate maintenance of straight-forward heading during everyday navigation and locomotion.

  1. Point Organ Radiation Dose in Abdominal CT: Effect of Patient Off-Centering in an Experimental Human Cadaver Study.

    Science.gov (United States)

    Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K

    2017-08-01

    To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p 92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Quantifying surgical access in eyebrow craniotomy with and without orbital bar removal: cadaver and surgical phantom studies.

    Science.gov (United States)

    Zador, Zsolt; Coope, David J; Gnanalingham, Kanna; Lawton, Michael T

    2014-04-01

    Eyebrow craniotomy is a recently described minimally invasive approach for tackling primarily pathology of the anterior skull base. The removal of the orbital bar may further expand the surgical corridor of this exposure, but the extent of benefit is poorly quantified. We assessed the effect of orbital bar removal with regards to surgical access in the eyebrow craniotomy using classic morphometric measurements in cadaver heads. Using surgical phantoms and neuronavigation, we also measured the 'working volume', a new parameter for characterising the volume of surgical access in these approaches. Silicon injected cadaver heads (n = 5) were used for morphometric analysis of the eyebrow craniotomy with and without orbital bar removal. Working depths and 'working areas' of surgical access were measured as defined by key anatomical landmarks. The eyebrow craniotomy with or without orbital bar removal was also simulated using surgical phantoms (n = 3, 90-120 points per trial), calibrated against a frameless neuronavigation system. Working volume was derived from reference coordinates recorded along the anatomical borders of the eyebrow craniotomy using the "α-shape algorithm" in R statistics. In cadaver heads, eyebrow craniotomy with removal of the orbital bar reduced the working depth to the ipsilateral anterior clinoid process (42 ± 2 versus 33 ± 3 mm; p < 0.05), but the working areas as defined by deep neurovascular and bony landmarks was statistically unchanged (total working areas of 418 ± 80 cm(2) versus 334 ± 48 cm(2); p = 0.4). In surgical phantom studies, however, working-volume for the simulated eyebrow craniotomies was increased with orbital bar removal (16 ± 1 cm(3) versus 21 ± 1 cm(3); p < 0.01). In laboratory studies, orbital bar removal in eyebrow craniotomy provides a modest reduction in working depth and increase in the working volume. But this must be weighed up against the added morbidity of the

  3. Cadavers Can Be Useful in Teaching Anatomy in College.

    Science.gov (United States)

    Stencel, John; Moore, John

    1989-01-01

    Presents information on student interest, teaching problems, and learning outcomes regarding the use of cadavers as a teaching tool. Provides a list of Illinois Community Colleges using cadavers and a student questionnaire. (RT)

  4. Portal placement in elbow arthroscopy by novice surgeons: cadaver study.

    Science.gov (United States)

    Claessen, Femke M A P; Kachooei, Amir R; Kolovich, Gregory P; Buijze, Geert A; Oh, Luke S; van den Bekerom, Michel P J; Doornberg, Job N

    2017-07-01

    In this anatomical cadaver study, the distance between major nerves and ligaments at risk for injury and portal sites created by trainees was measured. Trainees, inexperienced in elbow arthroscopy, have received a didactic lecture and cadaver instruction prior to portal placement. The incidence of iatrogenic injury from novice portal placement was also determined. Anterolateral, direct lateral, and anteromedial arthroscopic portals were created in ten cadavers by ten inexperienced trainees in elbow arthroscopy. After creating each portal, the trajectory of the portal was marked with a guide pin. Subsequently, the cadavers were dissected and the distances between the guide pin in the anterolateral, direct lateral, and anteromedial portals and important ligaments and nerves were measured. The difference between the distance of the direct lateral portal and the posterior antebrachial cutaneous nerve (PABCN) (22 mm, p cadaver instruction session alone. Level of evidence V.

  5. SIM Life: a new surgical simulation device using a human perfused cadaver.

    Science.gov (United States)

    Faure, J P; Breque, C; Danion, J; Delpech, P O; Oriot, D; Richer, J P

    2017-02-01

    In primary and continuing medical education, simulation is becoming a mandatory technique. In surgery, simulation spreading is slowed down by the distance which exists between the devices currently available on the market and the reality, in particular anatomical, of an operating room. We propose a new model for surgical simulation with the use of cadavers in a circulation model mimicking pulse and artificial respiration available for both open and laparoscopic surgery. The model was a task trainer designed by four experts in our simulation laboratory combining plastic, electronic, and biologic material. The cost of supplies needed for the construction was evaluated. The model was used and tested over 24 months on 35 participants, of whom 20 were surveyed regarding the realism of the model. The model involved a cadaver, connected to a specific device that permits beating circulation and artificial respiration. The demonstration contributed to teaching small groups of up to four participants and was reproducible over 24 months of courses. Anatomic correlation, realism, and learning experience were highly rated by users CONCLUSION: This model for surgical simulation in both open and laparoscopic surgery was found to be realistic, available to assessed objectively performance in a pedagogic program.

  6. A dictionary learning approach for human sperm heads classification.

    Science.gov (United States)

    Shaker, Fariba; Monadjemi, S Amirhassan; Alirezaie, Javad; Naghsh-Nilchi, Ahmad Reza

    2017-12-01

    To diagnose infertility in men, semen analysis is conducted in which sperm morphology is one of the factors that are evaluated. Since manual assessment of sperm morphology is time-consuming and subjective, automatic classification methods are being developed. Automatic classification of sperm heads is a complicated task due to the intra-class differences and inter-class similarities of class objects. In this research, a Dictionary Learning (DL) technique is utilized to construct a dictionary of sperm head shapes. This dictionary is used to classify the sperm heads into four different classes. Square patches are extracted from the sperm head images. Columnized patches from each class of sperm are used to learn class-specific dictionaries. The patches from a test image are reconstructed using each class-specific dictionary and the overall reconstruction error for each class is used to select the best matching class. Average accuracy, precision, recall, and F-score are used to evaluate the classification method. The method is evaluated using two publicly available datasets of human sperm head shapes. The proposed DL based method achieved an average accuracy of 92.2% on the HuSHeM dataset, and an average recall of 62% on the SCIAN-MorphoSpermGS dataset. The results show a significant improvement compared to a previously published shape-feature-based method. We have achieved high-performance results. In addition, our proposed approach offers a more balanced classifier in which all four classes are recognized with high precision and recall. In this paper, we use a Dictionary Learning approach in classifying human sperm heads. It is shown that the Dictionary Learning method is far more effective in classifying human sperm heads than classifiers using shape-based features. Also, a dataset of human sperm head shapes is introduced to facilitate future research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Analysis of ureteral length in adult cadavers

    Directory of Open Access Journals (Sweden)

    Hugo F. F. Novaes

    2013-04-01

    Full Text Available Introduction In some occasions, correlations between human structures can help planning surgical intra-abdominal interventions. The previous determination of ureteral length helps pre-operatory planning of surgeries, reduces costs of auxiliary exams, the correct choice of double-J catheter with low morbidity and fewer symptoms, and an adequate adhesion to treatment. Objective To evaluate ureteral length in adult cadavers and to analyze its correlation with anthropometric measures. Materials and Methods: From April 2009 to January 2012 we determined ureteral length of adult cadavers submitted to necropsy and obtained the following measures: height, distance from shoulder to wrist, elbow-wrist, xiphoid appendix-umbilicus, umbilicus-pubis, xiphoid appendix-pubis and between iliac spines. We analyzed the correlations between ureteral length and those anthropometric measures. Results We dissected 115 ureters from 115 adult corpses from April 2009 to January 2012. Median ureteral length didn't vary between sexes or according to height. It was observed no correlation among ureteral length and all considered anthropometric measures in all analyzed subgroups and in general population. There were no significant differences between right and left ureteral measures. Conclusions There is no difference of ureteral length in relation to height or gender (male or female. There is no significant correlation among ureteral length and the considered anthropometric measures.

  8. Anatomical aspects of the gastrocnemius muscles: A study in 47 fresh cadavers.

    Science.gov (United States)

    Andjelkov, Katarina; Atanasijevic, Tatjana C; Popovic, Vesna M; Sforza, Marcos; Atkinson, Connor J; Soldatovic, Ivan

    2016-08-01

    This study offers objective dimensions of the gastrocnemius muscle and analyzes correlations between dimensional variables, with a view to providing guidance on the proportions of a healthy gastrocnemius muscle for both genders. This anatomical study was conducted at the Institute of Forensic Medicine Faculty of Medicine University of Belgrade, Serbia, from May until November 2014. We included 47 fresh cadavers (up to 12-h postmortem interval) both male and female. The inclusion criteria were absence of any trauma or degenerative findings in lower limbs, normally weighed, and age between 18 and 60 years. The exclusion criteria were significant difference in dimensions between legs and overweighed cadavers. After statistical analysis of gathered data, we were able to define the exact shape and average measures of the medial and lateral head of gastrocnemius muscle in male and female. Factors affecting muscle dimensions are also defined in this study. The method of dissection that we applied could be recommended for exploration of different anatomical structures of calf region. The reported dimensions and correlations are useful guide in planning cosmetic and reconstructive procedures with high accuracy. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Cling film plastic wrap: An innovation for dead body packaging, preservation and transportation by first responders as a replacement for cadaver body bag in large scale disasters.

    Science.gov (United States)

    Khoo, Lay See; Lai, Poh Soon; Saidin, Mohd Hilmi; Noor, Zahari; Mahmood, Mohd Shah

    2018-04-01

    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. A comparative study of vascular injection fluids in fresh-frozen and embalmed human cadaver forearms

    NARCIS (Netherlands)

    Doomernik, D.E.; Kruse, R.R.; Reijnen, M.M.; Kozicz, T.; Kooloos, J.G.M.

    2016-01-01

    Over the years, various vascular injection products have been developed to facilitate anatomical dissections. This study aimed to compare the most commonly used vascular injection products in fresh-frozen and formalin-embalmed cadaver specimens. An overview of the properties, advantages and

  11. Coexistence of a pectoralis quartus muscle, a supernumerary head of biceps brachii muscle and an accessory head of flexor digitorum profundus muscle.

    Science.gov (United States)

    Song, Halim; Kim, Jinu; Yoon, Sang-Pil

    2018-05-26

    Although anatomical variations in the upper limb are frequent, coexistence of multiple combined variations is rare. During a routine educational dissection at Jeju National University Medical School, three muscular variations were found in a 75-year-old Korean male cadaver, in which a supraclavicular cephalic vein was also found in ipsilateral upper extremity during skinning (Go et al., 2017). Here we describe characteristics of the pectoralis quartus muscle, the supernumerary head of biceps brachii muscle and an accessory head of flexor digitorum profundus muscle, and discuss their coexistence from morphological and embryological points of view.

  12. Anne-Sylvie Catherin, Head of the Human Resources Department

    CERN Multimedia

    2009-01-01

    Anne-Sylvie Catherin has been appointed Head of the Human Resources Department with effect from 1 August 2009. Mrs Catherin is a lawyer specialized in International Administration and joined CERN in 1996 as legal advisor within the Office of the HR Department Head. After having been promoted to the position of Group Leader responsible for social and statutory conditions in 2000, Mrs Catherin was appointed Deputy of the Head of the Human Resources Department and Group Leader responsible for Strategy, Management and Development from 2005 to date. Since 2005, she has also served as a member of CCP and TREF. In the execution of her mandate as Deputy HR Department Head, Mrs Catherin closely assisted the HR Department Head in the organization of the Department and in devising new HR policies and strategies. She played an instrumental role in the last five-yearly review and in the revision of the Staff Rules and Regulations.

  13. Reprint of: Cling film plastic wrap: An innovation for dead body packaging, preservation and transportation by first responders as a replacement for cadaver body bag in large scale disasters.

    Science.gov (United States)

    Khoo, Lay See; Lai, Poh Soon; Saidin, Mohd Hilmi; Noor, Zahari; Mahmood, Mohd Shah

    2018-07-01

    Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. The Dimensions of the Orbital Cavity Based on High-Resolution Computed Tomography of Human Cadavers

    DEFF Research Database (Denmark)

    Felding, Ulrik Ascanius; Bloch, Sune Land; Buchwald, Christian von

    2016-01-01

    for surface area. To authors' knowledge, this study is the first to have measured the entire surface area of the orbital cavity.The volume and surface area of the orbital cavity were estimated in computed tomography scans of 11 human cadavers using unbiased stereological sampling techniques. The mean (± SD......) total volume and total surface area of the orbital cavities was 24.27 ± 3.88 cm and 32.47 ± 2.96 cm, respectively. There was no significant difference in volume (P = 0.315) or surface area (P = 0.566) between the 2 orbital cavities.The stereological technique proved to be a robust and unbiased method...... that may be used as a gold standard for comparison with automated computer software. Future imaging studies in blow-out fracture patients may be based on individual and relative calculation involving both herniated volume and fractured surface area in relation to the total volume and surface area...

  15. Oncogenic impact of human papilloma virus in head and neck cancer.

    LENUS (Irish Health Repository)

    Heffernan, C B

    2012-02-01

    There is considerable debate within the literature about the significance of human papilloma virus in head and neck squamous cell carcinoma, and its potential influence on the prevention, diagnosis, grading, treatment and prognosis of these cancers. Cigarette smoking and alcohol consumption have traditionally been cited as the main risk factors for head and neck cancers. However, human papilloma virus, normally associated with cervical and other genital carcinomas, has emerged as a possible key aetiological factor in head and neck squamous cell carcinoma, especially oropharyngeal cancers. These cancers pose a significant financial burden on health resources and are increasing in incidence. The recent introduction of vaccines targeted against human papilloma virus types 16 and 18, to prevent cervical cancer, has highlighted the need for ongoing research into the importance of human papilloma virus in head and neck squamous cell carcinoma.

  16. Cannula Versus Sharp Needle for Placement of Soft Tissue Fillers: An Observational Cadaver Study.

    Science.gov (United States)

    van Loghem, Jani A J; Humzah, Dalvi; Kerscher, Martina

    2017-12-13

    Soft-tissue fillers have become important products for facial rejuvenation. Deep fat compartments and facial bones lose volume during the natural aging process. For the most natural-looking results, deep volumetric injections at strategic sites are therefore preferred. Supraperiosteal placement is performed with a sharp needle or a non-traumatic cannula. The primary objective was to determine whether there is a difference in precision between supraperiosteal placement with a sharp needle compared with a non-traumatic cannula in cadaver specimens. A secondary objective was to analyze the safety profiles of both injection techniques. Cadaver heads were injected with dye material and soft-tissue fillers at multiple aesthetic facial sites on the supraperiosteum and subsequently dissected for observation of dye and filler placement. The non-traumatic cannula technique resulted in product being confined to the deep anatomic layers. In contrast, with the sharp needle technique, material was placed in multiple anatomic layers, from the periosteum to more superficial skin layers. For both techniques results were consistent for all facial sites. Although direct extrapolation from cadavers to the in vivo situation cannot be made, cannulae showed more precision in placement of product. With the sharp needle, the material was injected on the periosteum, and then migrated in a retrograde direction along the trajectory of the needle path, ending up in multiple anatomic layers. The sharp needle technique also showed a higher complication risk with intra-arterial injection occurring, even though the needle tip was positioned on the periosteum and the product was injected with the needle in constant contact with the periosteum. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com

  17. Subfracture insult to the human cadaver patellofemoral joint produces occult injury.

    Science.gov (United States)

    Atkinson, P J; Haut, R C

    1995-11-01

    The current criterion used by the automotive industry for injury to the lower extremity is based on visible bone fracture. Studies suggest, however, that chronic joint degeneration may occur after subfracture impact loads on the knee. We hypothesized that subfracture loading of the patellofemoral joint could result in previously undocumented microtrauma in areas of high contact pressure. In the current study, seven patellofemoral joints from human cadavers were subjected to impact with successively greater energy until visible fracture was noted. Transverse and comminuted fractures of the patella were noted at 6.7 kN of load. Approximately 45% of the impact energy then was delivered to the contralateral joint. Subfracture loads of 5.2 kN resulted in no gross bone fracture in five of seven specimens. Histological examination of the patellae horizontal split fracture in the subchondral bone, at the tidemark, or at the interface of calcified cartilage and subchondral bone. The trauma appeared predominantly on the lateral facet, adjacent to or directly beneath preexisting fibrillation of the articular surface. Surface fibrillation was noted in histological sections of control patellae (not subjected to impact loading), but occult damages were not observed. Although the mechanism of this occult trauma is unknown, similar damage has been shown to occur from direct shear loading. As these microcracks can potentiate a disease process in the joint, this study may suggest that the current criterion for injury, based on bone fracture alone, is not sufficiently conservative.

  18. Toxic effects of formalin-treated cadaver on medical students, staff ...

    African Journals Online (AJOL)

    Background: Formaldehyde can be toxic, allergenic and carcinogenic. Evaporation of formaldehyde from formalin-treated cadavers in the anatomy dissection rooms can produce high exposure. This study was conducted to assess acute and chronic toxic effects of formalin-treated cadavers on medical students, staff ...

  19. Optimizing CT technique to reduce radiation dose: effect of changes in kVp, iterative reconstruction, and noise index on dose and noise in a human cadaver.

    Science.gov (United States)

    Chang, Kevin J; Collins, Scott; Li, Baojun; Mayo-Smith, William W

    2017-06-01

    For assessment of the effect of varying the peak kilovoltage (kVp), the adaptive statistical iterative reconstruction technique (ASiR), and automatic dose modulation on radiation dose and image noise in a human cadaver, a cadaver torso underwent CT scanning at 80, 100, 120 and 140 kVp, each at ASiR settings of 0, 30 and 50 %, and noise indices (NIs) of 5.5, 11 and 22. The volume CT dose index (CTDI vol ), image noise, and attenuation values of liver and fat were analyzed for 20 data sets. Size-specific dose estimates (SSDEs) and liver-to-fat contrast-to-noise ratios (CNRs) were calculated. Values for different combinations of kVp, ASiR, and NI were compared. The CTDI vol varied by a power of 2 with kVp values between 80 and 140 without ASiR. Increasing ASiR levels allowed a larger decrease in CTDI vol and SSDE at higher kVp than at lower kVp while image noise was held constant. In addition, CTDI vol and SSDE decreased with increasing NI at each kVp, but the decrease was greater at higher kVp than at lower kVp. Image noise increased with decreasing kVp despite a fixed NI; however, this noise could be offset with the use of ASiR. The CT number of the liver remained unchanged whereas that of fat decreased as the kVp decreased. Image noise and dose vary in a complicated manner when the kVp, ASiR, and NI are varied in a human cadaver. Optimization of CT protocols will require balancing of the effects of each of these parameters to maximize image quality while minimizing dose.

  20. A comparative study of vascular injection fluids in fresh-frozen and embalmed human cadaver forearms.

    Science.gov (United States)

    Doomernik, D E; Kruse, R R; Reijnen, M M P J; Kozicz, T L; Kooloos, J G M

    2016-10-01

    Over the years, various vascular injection products have been developed to facilitate anatomical dissections. This study aimed to compare the most commonly used vascular injection products in fresh-frozen and formalin-embalmed cadaver specimens. An overview of the properties, advantages and limitations of each substance was given, and a comparison of vascular infusion procedures in both preservation methods was made. A literature search was performed in order to identify the most commonly used vascular injection products. Acrylic paint, latex, gelatin, silicone, Araldite F and Batson's No. 17 were selected for the study. One fresh-frozen and one embalmed cadaver forearm were infused with each injection product according to a uniform protocol. The curing time, skin- and subcutaneous tissue penetration, degree of filling of the arterial tree, extravasations, consistency of the injected vessels during dissection, and the costs of each injection fluid were noted. There was a large variation between the injection fluids in processing- and curing time, colour intensity, flexibility, fragility, elasticity, strength, toxicity and costs. All fluids were suitable for infusion. The penetration of injection fluid into the skin and subcutaneous tissue was significantly better in fresh-frozen specimens (P = 0.002 and P = 0.009, respectively), with significantly smaller branches casted (P = 0.004). Vascular infusion of fresh-frozen cadaver specimens results in a significantly better filled coloured arterial tree, enabling more detail to be achieved and smaller branches casted. The biomechanical properties of fresh-frozen soft tissues are less affected compared with formalin fixation. All the injection fluids studied are suitable for vascular infusion, but their different properties ensure that certain products and procedures are more suitable for specific study purposes. © 2016 Anatomical Society.

  1. [Identification and preservation of parathyroid glands in cadaver parts].

    Science.gov (United States)

    Melo, Catarina; Bernardes, António; Carvalho, Lina

    2013-01-01

    It is essential to know the thyroid gland morphology and its anatomical relations in the anterior compartment of the neck in order to minimize the rate of thyroid surgery morbidity, especially the lesion of parathyroid glands and laryngeal nerves. The aim of this study was the identification of parathyroid glands in cadaver parts and their histological confirmation. Twenty cadaver parts were used to simulate thyroidectomies. During dissection, the thyroid glands and eventual parathyroid glands were isolated and then submitted to histological study. Twenty cadaver parts (anterior cervical organs) were used for macroscopic dissection during which 48 fragments that corresponded to eventual parathyroid glands were isolated, 35 of which were effectively confirmed through histological observation to be parathyroid glands. The 20 cadaver parts were then divided into three groups according to the number of histologically confirmed parathyroid glands. In the first group, composed of 11 cases, all eventual parathyroid glands were confirmed. In the second group, composed of six cases, only some glands were confirmed. In the third group, composed of three cases, none of the possible glands were confirmed. In seven of the 20 isolated thyroid glands, eight parathyroid glands were identified during histological study: four subcapsular, three extra-capsular, one intra-thyroidal. There was no statistical relation in the dimensions of the parathyroid glands. The knowledge of the anatomy of the central visceral compartment of the neck and its most frequent variations reduces but doesn't eliminate thyroid surgery morbidity, especially parathyroid iatrogenic excision, difficulty which has been demonstrated during the dissection of cadaver parts.

  2. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  3. perception to cadaver dissection and views on anatomy as a subject

    African Journals Online (AJOL)

    However, literature on medical students' perceptions on cadaver dissection and their opinions on anatomy as a subject is scanty ... Key words: Dissection, Perceptions, Cadaver, Anatomy. INTRODUCTION. Dissection has been the .... attention they give to the learning of anatomy, and this may possibly explain the relatively.

  4. A new technique to characterize CT scanner bow-tie filter attenuation and applications in human cadaver dosimetry simulations

    Science.gov (United States)

    Li, Xinhua; Shi, Jim Q.; Zhang, Da; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Kalra, Mannudeep K.; Xu, X. George; Liu, Bob

    2015-01-01

    Purpose: To present a noninvasive technique for directly measuring the CT bow-tie filter attenuation with a linear array x-ray detector. Methods: A scintillator based x-ray detector of 384 pixels, 307 mm active length, and fast data acquisition (model X-Scan 0.8c4-307, Detection Technology, FI-91100 Ii, Finland) was used to simultaneously detect radiation levels across a scan field-of-view. The sampling time was as short as 0.24 ms. To measure the body bow-tie attenuation on a GE Lightspeed Pro 16 CT scanner, the x-ray tube was parked at the 12 o’clock position, and the detector was centered in the scan field at the isocenter height. Two radiation exposures were made with and without the bow-tie in the beam path. Each readout signal was corrected for the detector background offset and signal-level related nonlinear gain, and the ratio of the two exposures gave the bow-tie attenuation. The results were used in the geant4 based simulations of the point doses measured using six thimble chambers placed in a human cadaver with abdomen/pelvis CT scans at 100 or 120 kV, helical pitch at 1.375, constant or variable tube current, and distinct x-ray tube starting angles. Results: Absolute attenuation was measured with the body bow-tie scanned at 80–140 kV. For 24 doses measured in six organs of the cadaver, the median or maximum difference between the simulation results and the measurements on the CT scanner was 8.9% or 25.9%, respectively. Conclusions: The described method allows fast and accurate bow-tie filter characterization. PMID:26520720

  5. Fabrication and characterization of scaffold from cadaver goat-lung tissue for skin tissue engineering applications

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Sweta K. [Department of Polymer and Process Engineering, Indian Institute of Technology, Roorkee (India); Dinda, Amit K. [Department of Pathology, All India Institute of Medical Sciences, New Delhi (India); Potdar, Pravin D. [Department of Molecular Medicine, Jaslok Hospital and Research Centre, Mumbai (India); Mishra, Narayan C., E-mail: mishrawise@gmail.com [Department of Polymer and Process Engineering, Indian Institute of Technology, Roorkee (India)

    2013-10-15

    The present study aims to fabricate scaffold from cadaver goat-lung tissue and evaluate it for skin tissue engineering applications. Decellularized goat-lung scaffold was fabricated by removing cells from cadaver goat-lung tissue enzymatically, to have cell-free 3D-architecture of natural extracellular matrix. DNA quantification assay and Hematoxylin and eosin staining confirmed the absence of cellular material in the decellularized lung-tissue. SEM analysis of decellularized scaffold shows the intrinsic porous structure of lung tissue with well-preserved pore-to-pore interconnectivity. FTIR analysis confirmed non-denaturation and well maintainance of collagenous protein structure of decellularized scaffold. MTT assay, SEM analysis and H and E staining of human skin-derived Mesenchymal Stem cell, seeded over the decellularized scaffold, confirms stem cell attachment, viability, biocompatibility and proliferation over the decellularized scaffold. Expression of Keratin18 gene, along with CD105, CD73 and CD44, by human skin-derived Mesenchymal Stem cells over decellularized scaffold signifies that the cells are viable, proliferating and migrating, and have maintained their critical cellular functions in the presence of scaffold. Thus, overall study proves the applicability of the goat-lung tissue derived decellularized scaffold for skin tissue engineering applications. - Highlights: • We successfully fabricated decellularized scaffold from cadaver goat-lung tissue. • Decellularized goat-lung scaffolds were found to be highly porous. • Skin derived MSC shows high cell viability and proliferation over the scaffold. • Phenotype of MSCs was well maintained over the scaffold. • The scaffold shows potential for applications in skin tissue engineering.

  6. Fabrication and characterization of scaffold from cadaver goat-lung tissue for skin tissue engineering applications

    International Nuclear Information System (INIS)

    Gupta, Sweta K.; Dinda, Amit K.; Potdar, Pravin D.; Mishra, Narayan C.

    2013-01-01

    The present study aims to fabricate scaffold from cadaver goat-lung tissue and evaluate it for skin tissue engineering applications. Decellularized goat-lung scaffold was fabricated by removing cells from cadaver goat-lung tissue enzymatically, to have cell-free 3D-architecture of natural extracellular matrix. DNA quantification assay and Hematoxylin and eosin staining confirmed the absence of cellular material in the decellularized lung-tissue. SEM analysis of decellularized scaffold shows the intrinsic porous structure of lung tissue with well-preserved pore-to-pore interconnectivity. FTIR analysis confirmed non-denaturation and well maintainance of collagenous protein structure of decellularized scaffold. MTT assay, SEM analysis and H and E staining of human skin-derived Mesenchymal Stem cell, seeded over the decellularized scaffold, confirms stem cell attachment, viability, biocompatibility and proliferation over the decellularized scaffold. Expression of Keratin18 gene, along with CD105, CD73 and CD44, by human skin-derived Mesenchymal Stem cells over decellularized scaffold signifies that the cells are viable, proliferating and migrating, and have maintained their critical cellular functions in the presence of scaffold. Thus, overall study proves the applicability of the goat-lung tissue derived decellularized scaffold for skin tissue engineering applications. - Highlights: • We successfully fabricated decellularized scaffold from cadaver goat-lung tissue. • Decellularized goat-lung scaffolds were found to be highly porous. • Skin derived MSC shows high cell viability and proliferation over the scaffold. • Phenotype of MSCs was well maintained over the scaffold. • The scaffold shows potential for applications in skin tissue engineering

  7. Development of a human head FE model for the impact analysis using VOXEL approach and simulation for the assessment on the focal brain injury

    International Nuclear Information System (INIS)

    Watanabe, Dai; Yuge, Kohei; Nishimoto, Tetsuya; Murakami, Shigeyuki; Takao, Hiroyuki

    2008-01-01

    In this paper, a three-dimensional digital human-head model was developed and several dynamic analyses on the head trauma were conducted. This model was built up by the VOXEL approach using 433 slice CT images (512 x 512 pixels) and made of 1.22 million parallelepiped finite elements with 10 anatomical tissue properties such as scalp, cerebrospinal fluid (CSF), skull, brain, dura mater and so on. The numerical analyses were conducted using a finite element code the authors have developed. The main features of the code are it is based on the explicit time integration method and it uses the one point integration method to evaluate the equivalent nodal forces with the hourglass control proposed by Flanagan and Belythcko and it utilizes the parallel computation with the Massage Passing Interface (MPI). In order to verify the developed model, the head impact experiment for a cadaver by Nahum et al. was simulated. The calculated results showed good agreement with experimental ones. A front and rear impact analyses were also performed investigate the relation between the impact direction and the positions of the high measurement of pressure and stresses in brain. The obtained results represent that brain injury has a closer relation with the Mises equivalent stress rather than the pressure. At this time, the large deformation of a frontal cranial base was observed in both frontal and occipital impact analyses. We expect that it induces the brain injury in a frontal lobe regardless of the impact positions. (author)

  8. An Economical Approach to Teaching Cadaver Anatomy: A 10-Year Retrospective

    Science.gov (United States)

    Simpson, Jeff S.

    2014-01-01

    Because of shrinking budgets and computerized virtual dissection programs, many large and small institutions are closing the door on traditional and expensive cadaver dissection classes. However, many health-care educators would argue there is still a place for cadaver dissection in higher education, so the continuing challenge is to provide the…

  9. Accuracy and Reliability of Cone-Beam Computed Tomography for Linear and Volumetric Mandibular Condyle Measurements. A Human Cadaver Study.

    Science.gov (United States)

    García-Sanz, Verónica; Bellot-Arcís, Carlos; Hernández, Virginia; Serrano-Sánchez, Pedro; Guarinos, Juan; Paredes-Gallardo, Vanessa

    2017-09-20

    The accuracy of Cone-Beam Computed Tomography (CBCT) on linear and volumetric measurements on condyles has only been assessed on dry skulls. The aim of this study was to evaluate the reliability and accuracy of linear and volumetric measurements of mandibular condyles in the presence of soft tissues using CBCT. Six embalmed cadaver heads were used. CBCT scans were taken, followed by the extraction of the condyles. The water displacement technique was used to calculate the volumes of the condyles and three linear measurements were made using a digital caliper, these measurements serving as the gold standard. Surface models of the condyles were obtained using a 3D scanner, and superimposed onto the CBCT images. Condyles were isolated on the CBCT render volume using the surface models as reference and volumes were measured. Linear measurements were made on CBCT slices. The CBCT method was found to be reliable for both volumetric and linear measurements (CV  0.90). Highly accurate values were obtained for the three linear measurements and volume. CBCT is a reliable and accurate method for taking volumetric and linear measurements on mandibular condyles in the presence of soft tissue, and so a valid tool for clinical diagnosis.

  10. Safety of lumbar spine radiofrequency procedures in the presence of posterior pedicle screws: technical report of a cadaver study.

    Science.gov (United States)

    Gazelka, Halena M; Welch, Tasha L; Nassr, Ahmad; Lamer, Tim J

    2015-05-01

    To determine whether the thermal energy associated with lumbar spine radiofrequency neurotomy (RFN) performed near titanium and stainless steel pedicle screws is conducted to the pedicle screws or adjacent tissues, or both, thus introducing potential for thermal damage to those tissues. Cadaver study. Cadaver laboratory equipped with fluoroscopy, surgical spine implements, and radiofrequency generator. No live human subject; a fresh frozen (and thawed) cadaver torso was used for the study. Titanium and stainless steel pedicle screws were placed in the lumbar spine of a fresh frozen cadaver torso with real-time fluoroscopic guidance. Conventional RFN cannula placement was performed at the level of pedicle screws and a control (nonsurgically altered) lumbar level. Neurotomy was performed with conventional radiofrequency lesioning parameters. Temperatures were recorded at multiple sites through thermistor probes. Direct contact of the radiofrequency cannula with the pedicle screws during conventional RFN produced a substantial increase in temperature in the surrounding soft tissues. A small increase in temperature occurred at the same sites at the control level. Titanium and stainless steel pedicle screws are capable of sustaining large increases in temperature when the radiofrequency probe comes in contact with the screw. These results are suggestive that pedicle screws could serve as a possible source of tissue heating and thermal injury during RFN. Wiley Periodicals, Inc.

  11. Long-term effects of hydrated lime and quicklime on the decay of human remains using pig cadavers as human body analogues: Field experiments.

    Science.gov (United States)

    Schotsmans, Eline M J; Fletcher, Jonathan N; Denton, John; Janaway, Robert C; Wilson, Andrew S

    2014-05-01

    An increased number of police enquiries involving human remains buried with lime have demonstrated the need for more research into the effect of different types of lime on cadaver decomposition and its micro-environment. This study follows previous studies by the authors who have investigated the effects of lime on the decay of human remains in laboratory conditions and 6 months of field experiments. Six pig carcasses (Sus scrofa), used as human body analogues, were buried without lime with hydrated lime (Ca(OH)2) and quicklime (CaO) in shallow graves in sandy-loam soil in Belgium and recovered after 17 and 42 months of burial. Analysis of the soil, lime and carcasses included entomology, pH, moisture content, microbial activity, histology and lime carbonation. The results of this study demonstrate that despite conflicting evidence in the literature, the extent of decomposition is slowed down by burial with both hydrated lime and quicklime. The more advanced the decay process, the more similar the degree of liquefaction between the limed and unlimed remains. The end result for each mode of burial will ultimately result in skeletonisation. This study has implications for the investigation of clandestine burials, for a better understanding of archaeological plaster burials and potentially for the interpretation of mass graves and management of mass disasters by humanitarian organisation and DVI teams. Copyright © 2014. Published by Elsevier Ireland Ltd.

  12. Cadaver-based training is superior to simulation training for cricothyrotomy and tube thoracostomy.

    Science.gov (United States)

    Takayesu, James Kimo; Peak, David; Stearns, Dana

    2017-02-01

    Emergency medicine (EM) training mandates that residents be able to competently perform low-frequency critical procedures upon graduation. Simulation is the main method of training in addition to clinical patient care. Access to cadaver-based training is limited due to cost and availability. The relative fidelity and perceived value of cadaver-based simulation training is unknown. This pilot study sought to describe the relative value of cadaver training compared to simulation for cricothyrotomy and tube thoracostomy. To perform a pilot study to assess whether there is a significant difference in fidelity and educational experience of cadaver-based training compared to simulation training. To understand how important this difference is in training residents in low-frequency procedures. Twenty-two senior EM residents (PGY3 and 4) who had completed standard simulation training on cricothyrotomy and tube thoracostomy participated in a formalin-fixed cadaver training program. Participants were surveyed on the relative fidelity of the training using a 100 point visual analogue scale (VAS) with 100 defined as equal to performing the procedure on a real patient. Respondents were also asked to estimate how much the cadaveric training improved the comfort level with performing the procedures on a scale between 0 and 100 %. Open-response feedback was also collected. The response rate was 100 % (22/22). The average fidelity of the cadaver versus simulation training was 79.9 ± 7.0 vs. 34.7 ± 13.4 for cricothyrotomy (p Cadaver-based training provides superior landmark and tissue fidelity compared to simulation training and may be a valuable addition to EM residency training for certain low-frequency procedures.

  13. Effects of hydrated lime and quicklime on the decay of buried human remains using pig cadavers as human body analogues.

    Science.gov (United States)

    Schotsmans, Eline M J; Denton, John; Dekeirsschieter, Jessica; Ivaneanu, Tatiana; Leentjes, Sarah; Janaway, Rob C; Wilson, Andrew S

    2012-04-10

    Recent casework in Belgium involving the search for human remains buried with lime, demonstrated the need for more detailed understanding of the effect of different types of lime on cadaver decomposition and its micro-environment. Six pigs (Sus scrofa) were used as body analogues in field experiments. They were buried without lime, with hydrated lime (Ca(OH)(2)) and with quicklime (CaO) in shallow graves in sandy loam soil in Belgium and recovered after 6 months of burial. Observations from these field recoveries informed additional laboratory experiments that were undertaken at the University of Bradford, UK. The combined results of these studies demonstrate that despite conflicting evidence in the literature, hydrated lime and quicklime both delay the decay of the carcass during the first 6 months. This study has implications for the investigation of clandestine burials and for a better understanding of archaeological plaster burials. Knowledge of the effects of lime on decomposition processes also has bearing on practices involving burial of animal carcasses and potentially the management of mass graves and mass disasters by humanitarian organisations and DVI teams. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  14. Digital Cadavers: Online 2D Learning Resources Enhance Student Learning in Practical Head and Neck Anatomy within Dental Programs

    Directory of Open Access Journals (Sweden)

    Mahmoud M. Bakr

    2016-01-01

    Full Text Available Head and neck anatomy provides core concepts within preclinical dental curricula. Increased student numbers, reduced curricula time, and restricted access to laboratory-based human resources have increased technology enhanced learning approaches to support student learning. Potential advantages include cost-effectiveness, off-campus access, and self-directed review or mastery opportunities for students. This study investigated successful student learning within a first-year head and neck anatomy course at the School of Dentistry and Oral Health, Griffith University, Australia, taught by the same teaching team, between 2010 and 2015. Student learning success was compared, for cohorts before and after implementation of a supplementary, purpose-designed online digital library and quiz bank. Success of these online resources was confirmed using overall students’ performance within the course assessment tasks and Student Evaluation of Course surveys and online access data. Engagement with these supplementary 2D online resources, targeted at improving laboratory study, was positively evaluated by students (mean 85% and significantly increased their laboratory grades (mean difference 6%, P<0.027, despite being assessed using cadaveric resources. Written assessments in final exams were not significantly improved. Expanded use of supplementary online resources is planned to support student learning and success in head and neck anatomy, given the success of this intervention.

  15. Absence of musculocutaneous nerve and accessory head of biceps brachii: a case report

    Directory of Open Access Journals (Sweden)

    Arora L

    2005-01-01

    Full Text Available During dissection of a 55-year-old female cadaver, we observed that three nerve roots contributed to the formation of Median nerve in her right upper limb. Along with this variation, absence of Musculocutaneous nerve was noticed. The muscles of front of arm i.e. Biceps Brachii, Brachialis and Coracobrachialis received their nerve supply from Median nerve. The Lateral cutaneous nerve of forearm was derived from Median nerve. Also an accessory head of Biceps Brachii muscle was present in the right arm of the same cadaver. It is extremely important to be aware of these variations while planning a surgery in the region of axilla or arm as these nerves are more liable to be injured during operations.

  16. THREE DIMENSIONAL DIGITIZATION OF HUMAN HEAD BY FUSING STRUCTURED LIGHT AND CONTOURS

    Institute of Scientific and Technical Information of China (English)

    Jin Gang; Li Dehua; Hu Hanping; Hu Bing

    2002-01-01

    Three dimensional digitization of human head is desired in many applications. In this paper, an information fusion based scheme is presented to obtain 3-D information of human head. Structured light technology is employed to measure depth. For the special reflection areas,in which the structured light stripe can not be detected directly, the shape of the structured light stripe can be calculated from the corresponding contour. By fusing the information of structured light and the contours, the problem of reflectance influence is solved, and the whole shape of head,including hair area, can be obtained. Some good results are obtained.

  17. Upper and Lower Urinary Tract Endoscopy Training on Thiel-embalmed Cadavers.

    Science.gov (United States)

    Bele, Uros; Kelc, Robi

    2016-07-01

    To evaluate Thiel-embalmed cadavers as a new training model for urological endoscopy procedures. Twelve urologists performed upper and lower urinary tract endoscopies on 5 different Thiel-embalmed cadavers to evaluate this potentially new training model in urological endoscopic procedural training. Using a 5-point Likert scale, the participants assessed the quality of the tissue and the overall experience of the endoscopy in comparison to a live patient procedure. Thiel-embalmed cadavers have shown to mimic live patient endoscopy of the upper and lower urinary tract in terms of almost identical overall anatomical conditions and manipulation characteristics of the tissue. The mucosa of the urethra and ureters showed similar colors and consistency in comparison to a live patient, whereas bladder mucosa was lacking the visibility of the vessels, thus was unsuitable for identifying any mucosal abnormalities. The flexibility of the muscles allowed for proper patient positioning, whereas the loss of muscle tonus made ureteroscopy more difficult although sufficiently comparable to the procedure done in a live patient. Thiel-embalmed cadavers have already been proven to be a suitable training model for several medical procedures. They are known for preserving tissue color, consistency, and flexibility without the irritant odors or risk of infection, which make them resemble live patients with real-life surgical challenges. The results of our study strongly suggest that despite some minor drawbacks, Thiel-embalmed cadavers are a suitable simulation model for initial training of urethrocystoscopy and ureteroscopy. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Growth trajectories of the human embryonic head and periconceptional maternal conditions.

    Science.gov (United States)

    Koning, I V; Baken, L; Groenenberg, I A L; Husen, S C; Dudink, J; Willemsen, S P; Gijtenbeek, M; Koning, A H J; Reiss, I K M; Steegers, E A P; Steegers-Theunissen, R P M

    2016-05-01

    Can growth trajectories of the human embryonic head be created using 3D ultrasound (3D-US) and virtual reality (VR) technology, and be associated with second trimester fetal head size and periconceptional maternal conditions? Serial first trimester head circumference (HC) and head volume (HV) measurements were used to create reliable growth trajectories of the embryonic head, which were significantly associated with fetal head size and periconceptional maternal smoking, age and ITALIC! in vitro fertilization (IVF)/intra-cytoplasmic sperm injection (ICSI) treatment. Fetal growth is influenced by periconceptional maternal conditions. We selected 149 singleton pregnancies with a live born non-malformed fetus from the Rotterdam periconception cohort. Bi-parietal diameter and occipital frontal diameter to calculate HC, HV and crown-rump length (CRL) were measured weekly between 9 + 0 and 12 + 6 weeks gestational age (GA) using 3D-US and VR. Fetal HC was obtained from second trimester structural anomaly scans. Growth trajectories of the embryonic head were created with general additive models and linear mixed models were used to estimate associations with maternal periconceptional conditions as a function of GA and CRL, respectively. A total of 303 3D-US images of 149 pregnancies were eligible for embryonic head measurements (intra-class correlation coefficients >0.99). Associations were found between embryonic HC and fetal HC ( ITALIC! ρ = 0.617, ITALIC! P head measured by HC and HV (All ITALIC! P head may be of benefit in future early antenatal care. This study was funded by the Department of Obstetrics and Gynaecology, Erasmus MC University Medical Centre and Sophia Foundation for Medical Research, Rotterdam, The Netherlands (SSWO grant number 644). No competing interests are declared. © The Author 2016. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please email

  19. "Detached Concern" of Medical Students in a Cadaver Dissection Course: A Phenomenological Study

    Science.gov (United States)

    Tseng, Wei-Ting; Lin, Ya-Ping

    2016-01-01

    The cadaver dissection course remains a time-honored tradition in medical education, partly because of its importance in cultivating professional attitudes in students. This study aims to investigate students' attitudes--specifically characterized as "detached concern"--in a cadaver dissection course. An interpretative phenomenological…

  20. Development of an ultrasound-guided technique for pudendal nerve block in cat cadavers.

    Science.gov (United States)

    Adami, Chiara; Angeli, Giovanni; Haenssgen, Kati; Stoffel, Michael H; Spadavecchia, Claudia

    2013-10-01

    The objective of this prospective experimental cadaveric study was to develop an ultrasound-guided technique to perform an anaesthetic pudendal nerve block in male cats. Fifteen fresh cadavers were used for this trial. A detailed anatomical dissection was performed on one cat in order to scrutinise the pudendal nerve and its ramifications. In a second step, the cadavers of six cats were used to test three different ultrasonographic approaches to the pudendal nerve: the deep dorso-lateral, the superficial dorso-lateral and the median transperineal. Although none of the approaches allowed direct ultrasonographical identification of the pudendal nerve branches, the deep dorso-lateral was found to be the most advantageous one in terms of practicability and ability to identify useful and reliable landmarks. Based on these findings, the deep dorso-lateral approach was selected as technique of choice for tracer injections (0.1 ml 1% methylene blue injected bilaterally) in six cat cadavers distinct from those used for the ultrasonographical study. Anatomical dissection revealed a homogeneous spread of the tracer around the pudendal nerve sensory branches in all six cadavers. Finally, computed tomography was performed in two additional cadavers after injection of 0.3 ml/kg (0.15 ml/kg per each injection sites, left and right) contrast medium through the deep dorso-lateral approach in order to obtain a model of volume distribution applicable to local anaesthetics. Our findings in cat cadavers indicate that ultrasound-guided pudendal nerve block is feasible and could be proposed to provide peri-operative analgesia in clinical patients undergoing perineal urethrostomy.

  1. Flexible Vesiculovasoscopy Using a Microoptical System in a Human Cadaver Model: An Experimental Approach for Atraumatic Endoscopy of the Seminal Tract.

    Science.gov (United States)

    Schlager, Daniel; Maas, Moritz; Hein, Simon; Adams, Fabian; Schoenthaler, Martin; Wetterauer, Ulrich; Diemer, Thorsten; Weidner, Wolfgang; Miernik, Arkadiusz

    2016-08-01

    The most common pathologies of the seminal tract are persistent hematospermia, seminal vesicle stones, and seminal duct obstruction. Endoscopic diagnostic work-up of the seminal tract is impeded by complex anatomy and lack of technical equipment. To date, there is no standardized endoscopic approach. The purpose of this study was to investigate the applicability and feasibility of a flexible microoptical device for atraumatic endoscopy of the seminal tract in a male human cadaver. The transurethral endoscopic examination was performed on a male cadaver. No premortal interventions or diseases of the genitourinary tract had been reported. The seminal orifice was identified via cystoscopy and accessed by the Seldinger technique using a hydrophilic guidewire and ureteral catheter. Retrograde endoscopic inspection of the distal seminal tract was performed using a miniaturized flexible endoscope. An antegrade endoscopic inspection of the seminal tract was carried out via high scrotal access to the vas deferens. Structures of the seminal tract, such as the ejaculatory duct, seminal vesicles, and distal portion of the ductus deferentes, were visualized using the miniaturized endoscope. Image quality allowed identification of anatomical structures and characterization of tissue properties. The technical limitations we observed involved the system's maneuverability. Initial results of this novel endoscopic approach to the seminal tract using a flexible microoptical system are encouraging. However, considerable anatomical limitations of the targeted organs necessitate further refinements of the technical equipment. This approach might improve diagnostics and treatment of genitourinary diseases. Future surgical techniques may include intraseminal laser therapy or endoocclusion to monitor fertility in men.

  2. Why infest the loved ones--inherent human behaviour indicates former mutualism with head lice.

    Science.gov (United States)

    Rózsa, Lajos; Apari, Péter

    2012-05-01

    Head lice transmit to new hosts when people lean their heads together. Humans frequently touch their heads to express friendship or love, while this behaviour is absent in apes. We hypothesize that this behaviour was adaptive because it enabled people to acquire head lice infestations as early as possible to provoke an immune response effective against both head lice and body lice throughout the subsequent periods of their life. This cross-immunity could provide some defence against the body-louse-borne lethal diseases like epidemic typhus, trench fever, relapsing fever and the classical plague. Thus the human 'touching heads' behaviour probably acts as an inherent and unconscious 'vaccination' against body lice to reduce the threat exposed by the pathogens they may transmit. Recently, the eradication of body-louse-borne diseases rendered the transmission of head lice a maladaptive, though still widespread, behaviour in developed societies.

  3. Practical guidelines for setting up neurosurgery skills training cadaver laboratory in India.

    Science.gov (United States)

    Suri, Ashish; Roy, Tara Sankar; Lalwani, Sanjeev; Deo, Rama Chandra; Tripathi, Manjul; Dhingra, Renu; Bhardwaj, Daya Nand; Sharma, Bhawani Shankar

    2014-01-01

    Though the necessity of cadaver dissection is felt by the medical fraternity, and described as early as 600 BC, in India, there are no practical guidelines available in the world literature for setting up a basic cadaver dissection laboratory for neurosurgery skills training. Hands-on dissection practice on microscopic and endoscopic procedures is essential in technologically demanding modern neurosurgery training where ethical issues, cost constraints, medico-legal pitfalls, and resident duty time restrictions have resulted in lesser opportunities to learn. Collaboration of anatomy, forensic medicine, and neurosurgery is essential for development of a workflow of cadaver procurement, preservation, storage, dissection, and disposal along with setting up the guidelines for ethical and legal concerns.

  4. Electric cadavers, 'metiphor,' and other medical software marvels.

    Science.gov (United States)

    Weiss, M

    1991-04-01

    "Grateful Med," "Fluids," "Metiphor," virtual reality, and electric cadavers are just some of the programs and buzzwords in the futuristic world of medical software affecting many areas of health care.

  5. Animation of 3D Model of Human Head

    Directory of Open Access Journals (Sweden)

    V. Michalcin

    2007-04-01

    Full Text Available The paper deals with the new algorithm of animation of 3D model of the human head in combination with its global motion. The designed algorithm is very fast and with low calculation requirements, because it does not need the synthesis of the input videosequence for estimation of the animation parameters as well as the parameters of global motion. The used 3D model Candide generates different expressions using its animation units which are controlled by the animation parameters. These ones are estimated on the basis of optical flow without the need of extracting of the feature points in the frames of the input videosequence because they are given by the selected vertices of the animation units of the calibrated 3D model Candide. The established multiple iterations inside the designed animation algorithm of 3D model of the human head between two successive frames significantly improved its accuracy above all for the large motion.

  6. Return of the cadaver

    Science.gov (United States)

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-01-01

    Abstract Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques. In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised. Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study. Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures. PMID:28723767

  7. Variations of the attachment of the superior head of human lateral pterygoid muscle.

    Science.gov (United States)

    Antonopoulou, Maria; Iatrou, Ioannis; Paraschos, Alexandros; Anagnostopoulou, Sophia

    2013-09-01

    The superior head of the lateral pterygoid muscle (LPM), is closely related to the temporomandibular joint (TMJ) and plays a role in the aetiology of temporomandibular disorders. Increased activity of this muscle has been implicated in the anterior displacement of the TMJ disc. However, there is uncertainty about the manner of the LPM attachment to the disc-condyle complex. The aim of this study was to investigate the exact anatomy of the attachment of the superior head of the LPM (SLPM) to the disc-condyle complex of the TMJ. Thirty-six TMJs were examined - both sides of 18 Greek cadavers (eight males and 10 females, mean age 79.6 years). Examination of the attachment of the SLPM was undertaken viewed under the dissecting microscope. Variation in the attachment of the SLPM was categorized into three types: in type I, the SLPM inserted into the condyle and the disc-capsule complex (55.5%). In type II, the SLPM only inserted into the condyle (27.8%). In type III, the SLPM inserted purely into the disc-capsule complex (16.7%). This study demonstrates that there are three different attachment types of the SLPM to the disc-condyle complex. The type III variation could be involved in the TMJ pathology. The knowledge of the variations of the SLPM attachment could be useful for precise surgical and pharmaceutical approaches. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Genotyping of human lice suggests multiple emergencies of body lice from local head louse populations.

    Directory of Open Access Journals (Sweden)

    Wenjun Li

    Full Text Available BACKGROUND: Genetic analyses of human lice have shown that the current taxonomic classification of head lice (Pediculus humanus capitis and body lice (Pediculus humanus humanus does not reflect their phylogenetic organization. Three phylotypes of head lice A, B and C exist but body lice have been observed only in phylotype A. Head and body lice have different behaviours and only the latter have been involved in outbreaks of infectious diseases including epidemic typhus, trench fever and louse borne recurrent fever. Recent studies suggest that body lice arose several times from head louse populations. METHODS AND FINDINGS: By introducing a new genotyping technique, sequencing variable intergenic spacers which were selected from louse genomic sequence, we were able to evaluate the genotypic distribution of 207 human lice. Sequence variation of two intergenic spacers, S2 and S5, discriminated the 207 lice into 148 genotypes and sequence variation of another two intergenic spacers, PM1 and PM2, discriminated 174 lice into 77 genotypes. Concatenation of the four intergenic spacers discriminated a panel of 97 lice into 96 genotypes. These intergenic spacer sequence types were relatively specific geographically, and enabled us to identify two clusters in France, one cluster in Central Africa (where a large body louse outbreak has been observed and one cluster in Russia. Interestingly, head and body lice were not genetically differentiated. CONCLUSIONS: We propose a hypothesis for the emergence of body lice, and suggest that humans with both low hygiene and head louse infestations provide an opportunity for head louse variants, able to ingest a larger blood meal (a required characteristic of body lice, to colonize clothing. If this hypothesis is ultimately supported, it would help to explain why poor human hygiene often coincides with outbreaks of body lice. Additionally, if head lice act as a reservoir for body lice, and that any social degradation in

  9. Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:: A Human Cadaver Study.

    Science.gov (United States)

    Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K

    2016-05-01

    The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. Fabrication and characterization of scaffold from cadaver goat-lung tissue for skin tissue engineering applications.

    Science.gov (United States)

    Gupta, Sweta K; Dinda, Amit K; Potdar, Pravin D; Mishra, Narayan C

    2013-10-01

    The present study aims to fabricate scaffold from cadaver goat-lung tissue and evaluate it for skin tissue engineering applications. Decellularized goat-lung scaffold was fabricated by removing cells from cadaver goat-lung tissue enzymatically, to have cell-free 3D-architecture of natural extracellular matrix. DNA quantification assay and Hematoxylin and eosin staining confirmed the absence of cellular material in the decellularized lung-tissue. SEM analysis of decellularized scaffold shows the intrinsic porous structure of lung tissue with well-preserved pore-to-pore interconnectivity. FTIR analysis confirmed non-denaturation and well maintainance of collagenous protein structure of decellularized scaffold. MTT assay, SEM analysis and H&E staining of human skin-derived Mesenchymal Stem cell, seeded over the decellularized scaffold, confirms stem cell attachment, viability, biocompatibility and proliferation over the decellularized scaffold. Expression of Keratin18 gene, along with CD105, CD73 and CD44, by human skin-derived Mesenchymal Stem cells over decellularized scaffold signifies that the cells are viable, proliferating and migrating, and have maintained their critical cellular functions in the presence of scaffold. Thus, overall study proves the applicability of the goat-lung tissue derived decellularized scaffold for skin tissue engineering applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. HLA AND CROSS·REACTIVE ANTIGEN GROUP MATCHING FOR CADAVER KIDNEY ALLOCATION1

    Science.gov (United States)

    Starzl, Thomas E.; Eliasziw, Michael; Gjertson, David; Terasaki, Paul I.; Fung, John J.; Trucco, Massimo; Martell, Joan; McMichael, John; Scantlebury, Velma; Shapiro, Ron; Donner, Allan

    2010-01-01

    Background Allocation of cadaver kidneys by graded human leukocyte antigen (HLA) compatibility scoring arguably has had little effect on overall survival while prejudicing the transplant candidacy of African-American and other hard to match populations. Consequently, matching has been proposed of deduced amino acid residues of the individual HLA molecules shared by cross-reactive antigen groups (CREGs). We have examined the circumstances under which compatibility with either method impacted graft survival. Methods Using Cox proportional hazards regression modeling, we studied the relationship between levels of conventional HLA mismatch and other donor and recipient factors on primary cadaver kidney survival between 1981 and 1995 at the University of Pittsburgh (n=1,780) and in the United Network for Organ Sharing (UNOS) Scientific Registry during 1991–1995 (n=31,291). The results were compared with those obtained by the matching of amino acid residues that identified CREG-compatible cases with as many as four (but not five and six) HLA mismatches. Results With more than one HLA mismatch (>85% of patients in both series), most of the survival advantage of a zero mismatch was lost. None of the HLA loci were “weak.” In the UNOS (but not Pittsburgh) category of one-HLA mismatch (n=1334), a subgroup of CREG-matched recipients (35.3%) had better graft survival than the remaining 64.7%, who were CREG-mismatched. There was no advantage of a CREG match in the two- to four-HLA incompatibility tiers. Better graft survival with tacrolimus was observed in both the Pittsburgh and UNOS series. Conclusions Obligatory national sharing of cadaver kidneys is justifiable only for zero-HLA-mismatched kidneys. The potential value of CREG matching observed in the one-HLA-mismatched recipients of the UNOS (but not the Pittsburgh) experience deserves further study. PMID:9381546

  12. Muecas: A Multi-Sensor Robotic Head for Affective Human Robot Interaction and Imitation

    Directory of Open Access Journals (Sweden)

    Felipe Cid

    2014-04-01

    Full Text Available This paper presents a multi-sensor humanoid robotic head for human robot interaction. The design of the robotic head, Muecas, is based on ongoing research on the mechanisms of perception and imitation of human expressions and emotions. These mechanisms allow direct interaction between the robot and its human companion through the different natural language modalities: speech, body language and facial expressions. The robotic head has 12 degrees of freedom, in a human-like configuration, including eyes, eyebrows, mouth and neck, and has been designed and built entirely by IADeX (Engineering, Automation and Design of Extremadura and RoboLab. A detailed description of its kinematics is provided along with the design of the most complex controllers. Muecas can be directly controlled by FACS (Facial Action Coding System, the de facto standard for facial expression recognition and synthesis. This feature facilitates its use by third party platforms and encourages the development of imitation and of goal-based systems. Imitation systems learn from the user, while goal-based ones use planning techniques to drive the user towards a final desired state. To show the flexibility and reliability of the robotic head, the paper presents a software architecture that is able to detect, recognize, classify and generate facial expressions in real time using FACS. This system has been implemented using the robotics framework, RoboComp, which provides hardware-independent access to the sensors in the head. Finally, the paper presents experimental results showing the real-time functioning of the whole system, including recognition and imitation of human facial expressions.

  13. A novel device for head gesture measurement system in combination with eye-controlled human machine interface

    Science.gov (United States)

    Lin, Chern-Sheng; Ho, Chien-Wa; Chang, Kai-Chieh; Hung, San-Shan; Shei, Hung-Jung; Yeh, Mau-Shiun

    2006-06-01

    This study describes the design and combination of an eye-controlled and a head-controlled human-machine interface system. This system is a highly effective human-machine interface, detecting head movement by changing positions and numbers of light sources on the head. When the users utilize the head-mounted display to browse a computer screen, the system will catch the images of the user's eyes with CCD cameras, which can also measure the angle and position of the light sources. In the eye-tracking system, the program in the computer will locate each center point of the pupils in the images, and record the information on moving traces and pupil diameters. In the head gesture measurement system, the user wears a double-source eyeglass frame, so the system catches images of the user's head by using a CCD camera in front of the user. The computer program will locate the center point of the head, transferring it to the screen coordinates, and then the user can control the cursor by head motions. We combine the eye-controlled and head-controlled human-machine interface system for the virtual reality applications.

  14. The immunologic considerations in human head transplantation.

    Science.gov (United States)

    Hardy, Mark A; Furr, Allen; Barret, Juan P; Barker, John H

    2017-05-01

    The idea of head transplantation appears at first as unrealistic, unethical, and futile. Here we discuss immunological considerations in human head transplantation. In a separate accompanying article we discuss surgical, ethical, and psychosocial issues concerned in body-to-head transplantation (BHT) [1]. The success of such an unusual allograft, where the donor and the recipient can reject each other, depends on prevention of complex immunologic reactions, especially rejection of the head by the body (graft-vs-host) or probably less likely, the possibility of the head rejecting the total body allograft (host-vs-graft). The technical and immunologic difficulties are enormous, especially since rapid nerve and cord connections and regeneration have not yet been possible to achieve. In this article we begin by briefly reviewing neuro-immunologic issues that may favor BHT such as the blood brain barrier (BBB) and point out its shortcomings. And we touch on the cellular and humoral elements in the brain proper that differ in some respects from those in other organs and in the periphery. Based on recent successes in vascular composite allografts (VCAs), we will elaborate on potential specific advantages and difficulties in BHT of various available immunosuppressive medications already utilized in VCAs. The risk/benefit ratio of these drugs will be emphasized in relation to direct brain toxicity such as seizure disorders, interference, or promotion of nerve regeneration, and potentiation of cerebral viral infections. The final portion of this article will focus on pre-transplant immunologic manipulation of the deceased donor body along with pretreatment of the recipient. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  15. Evaluation of performance of two different chest tubes with either a sharp or a blunt tip for thoracostomy in 100 human cadavers

    Directory of Open Access Journals (Sweden)

    Ortner Clemens M

    2012-02-01

    Full Text Available Abstract Background Emergent placement of a chest tube is a potentially life-saving procedure, but rate of misplacement and organ injury is up to 30%. In principle, chest tube insertion can be performed by using Trocar or Non-trocar techniques. If using trocar technique, two different chest tubes (equipped with sharp or blunt tip are currently commercially available. This study was performed to detect any difference with respect to time until tube insertion, to success and to misplacement rate. Methods Twenty emergency physicians performed five tube thoracostomies using both blunt and sharp tipped tube kits in 100 fresh human cadavers (100 thoracostomies with each kit. Time until tube insertion served as primary outcome. Complications and success rate were examined by pathological dissection and served as further outcomes parameters. Results Difference in mean time until tube insertion (63s vs. 59s was statistically not significant. In both groups, time for insertion decreased from the 1st to the 5th attempt and showed dependency on the cadaver's BMI and on the individual physician. Success rate differed between both groups (92% using blunt vs. 86% using sharp tipped kits and injuries and misplacements occurred significantly more frequently using chest tubes with sharp tips (p = 0.04. Conclusion Data suggest that chest drain insertion with trocars is associated with a 6-14% operator-related complication rate. No difference in average time could be found. However, misplacements and organ injuries occurred more frequently using sharp tips. Consequently, if using a trocar technique, the use of blunt tipped kits is recommended.

  16. Splenorenal shunt via magnetic compression technique: a feasibility study in canine and cadaver.

    Science.gov (United States)

    Xue, Fei; Li, Jianpeng; Lu, Jianwen; Zhu, Haoyang; Liu, Wenyan; Zhang, Hongke; Yang, Huan; Guo, Hongchang; Lv, Yi

    2016-12-01

    The concept of magnetic compression technique (MCT) has been accepted by surgeons to solve a variety of surgical problems. In this study, we attempted to explore the feasibility of a splenorenal shunt using MCT in canine and cadaver. The diameters of the splenic vein (SV), the left renal vein (LRV), and the vertical interval between them, were measured in computer tomography (CT) images obtained from 30 patients with portal hypertension and in 20 adult cadavers. The magnetic devices used for the splenorenal shunt were then manufactured based on the anatomic parameters measured above. The observation of the anatomical structure showed there were no special structural tissues or any important organs between SV and LRV. Then the magnetic compression splenorenal shunt procedure was performed in three dogs and five cadavers. Seven days later, the necrotic tissue between the two magnets was shed and the magnets were removed with the anchor wire. The feasibility of splenorenal shunt via MCT was successfully shown in both canine and cadaver, thus providing a theoretical support for future clinical application.

  17. Head Pose Estimation Using Multilinear Subspace Analysis for Robot Human Awareness

    Science.gov (United States)

    Ivanov, Tonislav; Matthies, Larry; Vasilescu, M. Alex O.

    2009-01-01

    Mobile robots, operating in unconstrained indoor and outdoor environments, would benefit in many ways from perception of the human awareness around them. Knowledge of people's head pose and gaze directions would enable the robot to deduce which people are aware of the its presence, and to predict future motions of the people for better path planning. To make such inferences, requires estimating head pose on facial images that are combination of multiple varying factors, such as identity, appearance, head pose, and illumination. By applying multilinear algebra, the algebra of higher-order tensors, we can separate these factors and estimate head pose regardless of subject's identity or image conditions. Furthermore, we can automatically handle uncertainty in the size of the face and its location. We demonstrate a pipeline of on-the-move detection of pedestrians with a robot stereo vision system, segmentation of the head, and head pose estimation in cluttered urban street scenes.

  18. Free manual of cadaver dissection modifiable by other anatomists.

    Science.gov (United States)

    Chung, Beom Sun; Chung, Min Suk

    2015-06-01

    Even in the rapidly changing field of cadaver dissection, published guide books still play an important role in the anatomy lab. However, commercial manuals with lengthy volumes and inflexible copyrights have several limitations which can be complemented by open-source manuals. Recently, the authors have manufactured and distributed a free electronic dissection manual (anatomy.co.kr), where descriptions are written concisely and images are drawn schematically. Moreover, simplified signs are employed to represent the cadaver viewing angles and manner of dissection. Based on the original files of this manual, other anatomists can revise and utilize the descriptions and figures. We expect many updated versions of our manual to be shared between students all over the world.

  19. Mapping the articular contact area of the long head of the biceps tendon on the humeral head.

    Science.gov (United States)

    Morris, Brent J; Byram, Ian R; Lathrop, Ray A; Dunn, Warren R; Kuhn, John E

    2014-01-01

    The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB) in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P = 0.002) with a median ratio of 41% (36%, 47.5%). Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho = 1, P = 0.017) as were ratios of abduction area to full articular surface area (rho = 0.97, P = 0.005). The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  20. Probabilistic Mapping of Human Visual Attention from Head Pose Estimation

    Directory of Open Access Journals (Sweden)

    Andrea Veronese

    2017-10-01

    Full Text Available Effective interaction between a human and a robot requires the bidirectional perception and interpretation of actions and behavior. While actions can be identified as a directly observable activity, this might not be sufficient to deduce actions in a scene. For example, orienting our face toward a book might suggest the action toward “reading.” For a human observer, this deduction requires the direction of gaze, the object identified as a book and the intersection between gaze and book. With this in mind, we aim to estimate and map human visual attention as directed to a scene, and assess how this relates to the detection of objects and their related actions. In particular, we consider human head pose as measurement to infer the attention of a human engaged in a task and study which prior knowledge should be included in such a detection system. In a user study, we show the successful detection of attention to objects in a typical office task scenario (i.e., reading, working with a computer, studying an object. Our system requires a single external RGB camera for head pose measurements and a pre-recorded 3D point cloud of the environment.

  1. SAR in human head model due to resonant wireless power transfer system.

    Science.gov (United States)

    Zhang, Chao; Liu, Guoqiang; Li, Yanhong; Song, Xianjin

    2016-04-29

    Efficient mid-range wireless power transfer between transmitter and the receiver has been achieved based on the magnetic resonant coupling method. The influence of electromagnetic field on the human body due to resonant wireless power transfer system (RWPT) should be taken into account during the design process of the system. To analyze the transfer performance of the RWPT system and the change rules of the specific absorption rate (SAR) in the human head model due to the RWPT system. The circuit-field coupling method for a RWPT system with consideration of the displacement current was presented. The relationship between the spiral coil parameters and transfer performance was studied. The SAR in the human head model was calculated under two different exposure conditions. A system with output power higher than 10 W at 0.2 m distance operating at a frequency of approximately 1 MHz was designed. The FEM simulation results show the peak SAR value is below the safety limit which appeared when the human head model is in front of the transmitter. The simulation results agreed well with the experimental results, which verified the validity of the analysis and design.

  2. Alfuzosin hydrochloride transdermal films: evaluation of physicochemical, in vitro human cadaver skin permeation and thermodynamic parameters

    Directory of Open Access Journals (Sweden)

    Satyanarayan Pattnaik

    2009-12-01

    Full Text Available Purpose: The main objective of the investigation was to develop a transdermal therapeutic system for alfuzosin hydrochloride and to study the effects of polymeric system and loading dose on the in vitro skin permeation pattern. Materials and methods: Principles of experimental design have been exploited to develop the dosage form. Ratio of ethyl cellulose (EC and polyvinyl pyrrolidone (PVP and loading dose were selected as independent variables and their influence on the cumulative amount of alfuzosin hydrochloride permeated per cm2 of human cadaver skin at 24 h (Q24, permeation flux (J and steady state permeability coefficient (P SS were studied using experimental design. Various physicochemical parameters of the transdermal films were also evaluated. Activation energy for in vitro transdermal permeation has been estimated. Results: Ratio of EC and PVP was found to be the main influential factor for all the dependent variables studied. Drug loading dose was also found to influence the dependent variables but to a lesser extent. Physicochemical parameters of the prepared films were evaluated and found satisfactory. Activation energy for alfuzosin permeation has also been estimated and reported. Conclusion: The therapeutic system was found to be dermatologically non-irritant and hence, a therapeutically effective amount of alfuzosin hydrochloride can be delivered via a transdermal route.

  3. Acromioclavicular joint dislocations: radiological correlation between Rockwood classification system and injury patterns in human cadaver species.

    Science.gov (United States)

    Eschler, Anica; Rösler, Klaus; Rotter, Robert; Gradl, Georg; Mittlmeier, Thomas; Gierer, Philip

    2014-09-01

    The classification system of Rockwood and Young is a commonly used classification for acromioclavicular joint separations subdividing types I-VI. This classification hypothesizes specific lesions to anatomical structures (acromioclavicular and coracoclavicular ligaments, capsule, attached muscles) leading to the injury. In recent literature, our understanding for anatomical correlates leading to the radiological-based Rockwood classification is questioned. The goal of this experimental-based investigation was to approve the correlation between the anatomical injury pattern and the Rockwood classification. In four human cadavers (seven shoulders), the acromioclavicular and coracoclavicular ligaments were transected stepwise. Radiological correlates were recorded (Zanca view) with 15-kg longitudinal tension applied at the wrist. The resulting acromio- and coracoclavicular distances were measured. Radiographs after acromioclavicular ligament transection showed joint space enlargement (8.6 ± 0.3 vs. 3.1 ± 0.5 mm, p acromioclavicular joint space width increased to 16.7 ± 2.7 vs. 8.6 ± 0.3 mm, p acromioclavicular joint lesions higher than Rockwood type I and II. The clinical consequence for reconstruction of low-grade injuries might be a solely surgical approach for the acromioclavicular ligaments or conservative treatment. High-grade injuries were always based on additional structural damage to the coracoclavicular ligaments. Rockwood type V lesions occurred while muscle attachments were intact.

  4. Diet influences rates of carbon and nitrogen mineralization from decomposing grasshopper frass and cadavers

    Science.gov (United States)

    Insect herbivory can produce a pulse of mineral nitrogen (N) in soil from the decomposition of frass and cadavers. In this study we examined how diet quality affects rates of N and carbon (C) mineralization from grasshopper frass and cadavers. Frass was collected from grasshoppers fed natural or mer...

  5. Single-port unilateral transaxillary totally endoscopic thyroidectomy: A survival animal and cadaver feasibility study

    Directory of Open Access Journals (Sweden)

    Henrique Neubarth Phillips

    2016-01-01

    Full Text Available Background: Single-port unilateral axillary thyroidectomy has great potential to become a valid alternative technique for thyroid surgery. We tested the technique in a study on live animals and cadavers to evaluate the feasibility and reproducibility of the procedure. Materials and Methods: Institutional review board (IRB approval was obtained in our university by the Council of Ethics for the study in surviving animals and cadavers. Subtotal thyroidectomy using unilateral axillary single port was performed in five dogs and five cadavers. Performing incision in the axillary fossa, a disposable single port was inserted. The dissection progressed for creating a subcutaneous tunnel to the subplatysmal region; after opening the platysma muscle and separation of the strap muscles, the thyroid gland was identified. After key anatomical landmarks were identified, the dissection was started at the upper pole towards the bottom, and to the isthmus. Specimens were extracted intact through the tunnel. Clinical and laboratorial observations of the experimental study in a 15-day follow-up and intraoperative data were documented. Results: All surgeries were performed in five animals which survived 15 days without postoperative complications. In the surgeries successfully performed in five cadavers, anatomical landmarks were recognised and intraoperative dissection of recurrent nerves and parathyroid glands was performed. Mean operative time was 64 min (46-85 min in animals and 123 min (110-140 min in cadavers, with a good cosmetic outcome since the incision was situated in the axillary fold. Conclusion: The technique of single-port axillary unilateral thyroidectomy was feasible and reproducible in the cadavers and animal survival study, suggesting the procedure as an alternative to minimally invasive surgery of the neck.

  6. Human papilloma virus: a new risk factor in a subset of head and neck cancers.

    Science.gov (United States)

    Bisht, Manisha; Bist, Sampan Singh

    2011-01-01

    Head and neck cancer is the sixth most common malignancy worldwide. Tobacco smoking and alcohol consumption are two well known behavioral risk factors associated with head and neck cancer. Recently, evidence is mounting that infection with human papilloma virus, most commonly human papilloma virus-16 is responsible for a subset of head and neck squamous cell carcinoma especially tumors of tonsillar origin. The molecular pathway used by human papilloma virus to trigger malignant transformation of tissue is different from that of other well known risk factors, i.e. smoking and alcohol, associated with squamous cell carcinoma. Apparently, these subsets of patients with human papilloma virus positive tumor are more likely to have a better prognosis than human papilloma virus negative tumor. Considering this fact, the human papilloma virus infection should be determined in all oropharyngeal cancers since it can have a major impact on the decision making process of the treatment.

  7. A Comparison of Computed Tomographic, Radiographic, Gross and Histological, Dental, and Alveolar Findings in 30 Abnormal Cheek Teeth from Equine Cadavers.

    Science.gov (United States)

    Liuti, Tiziana; Smith, Sionagh; Dixon, Padraic M

    2017-01-01

    Equine cheek teeth disorders, especially pulpar/apical infections, can have very serious consequences due to the frequent extension of infection to the supporting bones and/or adjacent paranasal sinuses. Limited studies have assessed the accuracy of computed tomographic (CT) imaging in the diagnosis of these disorders, and no study has directly compared imaging and pathological findings of the alveoli of diseased equine cheek teeth. To validate the accuracy of CT and radiographic imaging of cheek teeth disorders by comparing CT and radiographic imaging, gross and histological findings in abnormal cheek teeth and their alveoli extracted from equine cadaver heads. Ex vivo original study. Fifty-four cadaver heads from horses with unknown histories that had died or been euthanized on humane grounds obtained from a rendering plant had radiography, CT imaging, and gross pathological examinations performed. Based on imaging and gross examination findings, 30 abnormal cheek teeth (26 maxillary and 4 mandibular) identified in 26 heads were extracted along with their dental alveoli where possible, and further CT imaging, gross, and histological examinations were performed. Eight maxillary cheek teeth (including four with attached alveolar bone) from these heads, that were normal on gross and CT examinations, were used as controls. Gross pathological and histological examinations indicated that 28/30 teeth, including two supernumerary teeth, had pulpar/apical infection, including pulpar and apical changes. A further supernumerary and a dysplastic tooth were also identified. Abnormal calcified tissue architecture was present in all three supernumerary and in the dysplastic tooth. CT imaging strongly indicated the presence of pulpar/apical infection in 27 of the 28 (96.4%) pulpar/apically infected teeth, including the presence of intrapulpar gas ( N  = 19/28), apical clubbing ( N  = 20), periapical halo ( N  = 4), root lysis or fragmentation ( N  = 7), and

  8. Porcine cadaver organ or virtual-reality simulation training for laparoscopic cholecystectomy: a randomized, controlled trial

    NARCIS (Netherlands)

    van Bruwaene, Siska; Schijven, Marlies P.; Napolitano, Daniel; de Win, Gunter; Miserez, Marc

    2015-01-01

    As conventional laparoscopic procedural training requires live animals or cadaver organs, virtual simulation seems an attractive alternative. Therefore, we compared the transfer of training for the laparoscopic cholecystectomy from porcine cadaver organs vs virtual simulation to surgery in a live

  9. Effects of External Loads on Human Head Movement Control Systems

    Science.gov (United States)

    Nam, M. H.; Choi, O. M.

    1984-01-01

    The central and reflexive control strategies underlying movements were elucidated by studying the effects of external loads on human head movement control systems. Some experimental results are presented on dynamic changes weigh the addition of aviation helmet (SPH4) and lead weights (6 kg). Intended time-optimal movements, their dynamics and electromyographic activity of neck muscles in normal movements, and also in movements made with external weights applied to the head were measured. It was observed that, when the external loads were added, the subject went through complex adapting processes and the head movement trajectory and its derivatives reached steady conditions only after transient adapting period. The steady adapted state was reached after 15 to 20 seconds (i.e., 5 to 6 movements).

  10. The dural entrance of cerebral bridging veins into the superior sagittal sinus: an anatomical comparison between cadavers and digital subtraction angiography

    International Nuclear Information System (INIS)

    Han, Hui; Tao, Wei; Zhang, Ming

    2007-01-01

    Intracranial venous structures have received increasing attention due to improved neuroimaging techniques and increased awareness of cerebral venous disease. To date, few studies have attempted to investigate the dural entrance of the cerebral bridging vein (BV). The aim of this study was to use the superior sagittal sinus (SSS) as an example to identify anatomical features of the dural entrance of the BVs into the SSS in both human cadavers and digital subtraction angiography (DSA) images. A total of 30 adult and 7 fetal human cadavers and 36 patients were examined with anatomical dissections, vascular casting and DSA. The number, diameter and angle of the BVs entering the SSS were measured and compared between the cadavers and DSA images. The results demonstrated that (1) the way a BV entered the SSS varied in three dimensions, and thus the BV dural entrance was difficult to precisely localize by DSA, (2) the distribution pattern of the dural entrance of the BVs into the SSS was relatively constant and a nontributary segment of the SSS was centered at the coronal suture and was identifiable by DSA, and (3) nearly all the BVs (97%, 561/581) entered the SSS at an angle opposite to the direction of blood flow. Unique anatomical features of the dural entrance of a BV into the SSS should be considered in neuroimaging interpretation of the sinus and its associated veins. (orig.)

  11. Validation of an optical system to measure acetabular shell deformation in cadavers.

    Science.gov (United States)

    Dold, Philipp; Bone, Martin C; Flohr, Markus; Preuss, Roman; Joyce, Tom J; Deehan, David; Holland, James

    2014-08-01

    Deformation of the acetabular shell at the time of surgery can result in poor performance and early failure of the hip replacement. The study aim was to validate an ATOS III Triple Scan optical measurement system against a co-ordinate measuring machine using in vitro testing and to check repeatability under cadaver laboratory conditions. Two sizes of custom-made acetabular shells were deformed using a uniaxial/two-point loading frame and measured at different loads. Roundness measurements were performed using both the ATOS III Triple Scan optical system and a co-ordinate measuring machine and then compared. The repeatability was also tested by measuring shells pre- and post-insertion in a cadaver laboratory multiple times. The in vitro comparison with the co-ordinate measuring machine demonstrated a maximum difference of 5 µm at the rim and 9 µm at the measurement closest to the pole of the shell. Maximum repeatability was below 1 µm for the co-ordinate measuring machine and 3 µm for the ATOS III Triple Scan optical system. Repeatability was comparable between the pre-insertion (below 2 µm) and post-insertion (below 3 µm) measurements in the cadaver laboratory. This study supports the view that the ATOS III Triple Scan optical system fulfils the necessary requirements to accurately measure shell deformation in cadavers. © IMechE 2014.

  12. A cadaver study of mastoidectomy using an image-guided human-robot collaborative control system.

    Science.gov (United States)

    Yoo, Myung Hoon; Lee, Hwan Seo; Yang, Chan Joo; Lee, Seung Hwan; Lim, Hoon; Lee, Seongpung; Yi, Byung-Ju; Chung, Jong Woo

    2017-10-01

    Surgical precision would be better achieved with the development of an anatomical monitoring and controlling robot system than by traditional surgery techniques alone. We evaluated the feasibility of robot-assisted mastoidectomy in terms of duration, precision, and safety. Human cadaveric study. We developed a multi-degree-of-freedom robot system for a surgical drill with a balancing arm. The drill system is manipulated by the surgeon, the motion of the drill burr is monitored by the image-guided system, and the brake is controlled by the robotic system. The system also includes an alarm as well as the brake to help avoid unexpected damage to vital structures. Experimental mastoidectomy was performed in 11 temporal bones of six cadavers. Parameters including duration and safety were assessed, as well as intraoperative damage, which was judged via pre- and post-operative computed tomography. The duration of mastoidectomy in our study was comparable with that required for chronic otitis media patients. Although minor damage, such as dura exposure without tearing, was noted, no critical damage to the facial nerve or other important structures was observed. When the brake system was set to 1 mm from the facial nerve, the postoperative average bone thicknesses of the facial nerve was 1.39, 1.41, 1.22, 1.41, and 1.55 mm in the lateral, posterior pyramidal and anterior, lateral, and posterior mastoid portions, respectively. Mastoidectomy can be successfully performed using our robot-assisted system while maintaining a pre-set limit of 1 mm in most cases. This system may thus be useful for more inexperienced surgeons. NA.

  13. Exploring metal artifact reduction using dual-energy CT with pre-metal and post-metal implant cadaver comparison: are implant specific protocols needed?

    NARCIS (Netherlands)

    Wellenberg, Ruud H. H.; Donders, Johanna C. E.; Kloen, Peter; Beenen, Ludo F. M.; Kleipool, Roeland P.; Maas, Mario; Streekstra, Geert J.

    2017-01-01

    To quantify and optimize metal artifact reduction using virtual monochromatic dual-energy CT for different metal implants compared to non-metal reference scans. Dual-energy CT scans of a pair of human cadaver limbs were acquired before and after implanting a titanium tibia plate, a stainless-steel

  14. Four Forensic Entomology Case Studies: Records and Behavioral Observations on Seldom Reported Cadaver Fauna With Notes on Relevant Previous Occurrences and Ecology.

    Science.gov (United States)

    Lindgren, Natalie K; Sisson, Melissa S; Archambeault, Alan D; Rahlwes, Brent C; Willett, James R; Bucheli, Sibyl R

    2015-03-01

    A yearlong survey of insect taxa associated with human decomposition was conducted at the Southeast Texas Applied Forensic Science (STAFS) facility located in the Center for Biological Field Studies of Sam Houston State University in Huntsville, TX. During this study, four insect-cadaver interactions were observed that represent previously poorly documented yet forensically significant interactions: Syrphidae maggots colonized a corpse in an aquatic situation; Psychodidae adults mated and oviposited on an algal film that was present on a corpse that had been recently removed from water; several Panorpidae were the first insects to feed upon a freshly placed corpse in the autumn; and a noctuid caterpillar was found chewing and ingesting dried human skin. Baseline knowledge of insect-cadaver interactions is the foundation of forensic entomology, and unique observations have the potential to expand our understanding of decomposition ecology. © The Author 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  15. The Wider Importance of Cadavers: Educational and Research Diversity from a Body Bequest Program

    Science.gov (United States)

    Cornwall, Jon; Stringer, Mark D.

    2009-01-01

    The debate surrounding the use of cadavers in teaching anatomy has focused almost exclusively on the pedagogic role of cadaver dissection in medical education. The aim of this study was to explore the wider aspects of a body bequest program for teaching and research into gross anatomy in a University setting. A retrospective audit was undertaken…

  16. Radiological assessment of the inferior alveolar artery course in human corpse mandibles

    Energy Technology Data Exchange (ETDEWEB)

    Bertl, Kristina [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Malmoe University, Department of Periodontology, Faculty of Odontology, Malmoe (Sweden); Hirtler, Lena [Medical University of Vienna, Center for Anatomy and Cell Biology, Department of Systematic Anatomy, Vienna (Austria); Dobsak, Toni [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Medical University of Vienna, Karl Donath Laboratory for Hard Tissue and Biomaterial Research, Division of Oral Surgery, Vienna (Austria); Austrian Cluster for Tissue Regeneration, Vienna (Austria); Heimel, Patrick [Medical University of Vienna, Karl Donath Laboratory for Hard Tissue and Biomaterial Research, Division of Oral Surgery, Vienna (Austria); Austrian Cluster for Tissue Regeneration, Vienna (Austria); Ludwig Boltzmann Institute for Clinical and Experimental Traumatology, Vienna (Austria); Gahleitner, Andre [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Medical University of Vienna, Department of Diagnostic Radiology, Division of Osteoradiology, General Hospital, Vienna (Austria); Ulm, Christian [Medical University of Vienna, Division of Oral Surgery, Bernhard Gottlieb School of Dentistry, Vienna (Austria); Plenk, Hanns [Medical University of Vienna, Bone and Biomaterials Research, Institute for Histology and Embryology, Vienna (Austria)

    2015-04-01

    CT assessment of the entire course of the inferior alveolar artery (IAA) within the mandibular canal. After contrast medium injection (180 or 400 mg/ml iodine concentration) into the external carotid arteries of 15 fresh human cadaver heads, the main IAA's position in the canal (cranial, buccal, lingual or caudal) was assessed in dental CT images of partially edentulous mandibles. The course of the main IAA could be followed at both iodine concentrations. The higher concentration gave the expected better contrast, without creating artefacts, and improved visibility of smaller arteries, such as anastomotic sections, dental branches and the incisive branch. The main IAA changed its position in the canal more often than so far known (mean 4.3 times, SD 1.24, range 2-7), but with a similar bilateral course. A cranial position was most often detected (42 %), followed by lingual (36 %), caudal (16 %) and buccal (6 %). With this non-invasive radiologic method, the entire course of the main IAA in the mandibular canal could be followed simultaneously with other bone structures on both sides of human cadaver mandibles. This methodology allows one to amend existing anatomical and histological data, which are important for surgical interventions near the mandibular canal. (orig.)

  17. Radiological assessment of the inferior alveolar artery course in human corpse mandibles

    International Nuclear Information System (INIS)

    Bertl, Kristina; Hirtler, Lena; Dobsak, Toni; Heimel, Patrick; Gahleitner, Andre; Ulm, Christian; Plenk, Hanns

    2015-01-01

    CT assessment of the entire course of the inferior alveolar artery (IAA) within the mandibular canal. After contrast medium injection (180 or 400 mg/ml iodine concentration) into the external carotid arteries of 15 fresh human cadaver heads, the main IAA's position in the canal (cranial, buccal, lingual or caudal) was assessed in dental CT images of partially edentulous mandibles. The course of the main IAA could be followed at both iodine concentrations. The higher concentration gave the expected better contrast, without creating artefacts, and improved visibility of smaller arteries, such as anastomotic sections, dental branches and the incisive branch. The main IAA changed its position in the canal more often than so far known (mean 4.3 times, SD 1.24, range 2-7), but with a similar bilateral course. A cranial position was most often detected (42 %), followed by lingual (36 %), caudal (16 %) and buccal (6 %). With this non-invasive radiologic method, the entire course of the main IAA in the mandibular canal could be followed simultaneously with other bone structures on both sides of human cadaver mandibles. This methodology allows one to amend existing anatomical and histological data, which are important for surgical interventions near the mandibular canal. (orig.)

  18. An experimental and numerical investigation of head dynamics due to stick impacts in girls' lacrosse.

    Science.gov (United States)

    Morse, Justin D; Franck, Jennifer A; Wilcox, Bethany J; Crisco, Joseph J; Franck, Christian

    2014-12-01

    A method of investigating head acceleration and intracranial dynamics from stick impacts in girls' and women's lacrosse was developed using headform impact experiments and a finite element head model. Assessing the likelihood of head injury due to stick-head impacts is of interest in girls' and women's lacrosse due to the current lack of head protection during play. Experimental and simulation data were compared to characterize the head acceleration caused by stick-head impacts. Validation against cadaver head impact experiments ensures that the finite element model, with its relatively simple material properties, can provide means to develop a better understanding of the intracranial dynamics during lacrosse stick impacts. Our numerical results showed the peak acceleration at the center of gravity increased linearly with impact force, and was generally in agreement with the experimental data. von Mises stresses and peak principal strains, two common literature injury indicators, were examined within the finite element model, and peak values were below the previously reported thresholds for mild traumatic brain injury. By reconstructing typical in-game, unprotected stick-head impacts, this investigation lays the foundation for a quantitative methodology of injury prediction in girls' and womens' lacrosse.

  19. Enrico Chiaveri, new Head of the Human Resources Department

    CERN Document Server

    2005-01-01

    Enrico Chiaveri has been appointed Head of the Human Resources Department of with effect from 1st April 2005. A senior physicist, Dr Chiaveri joined CERN in 1973. During his career, he has performed various management roles, including that of Deputy Leader of the SPS/LEP Division, and has acquired extensive experience in human resources matters. Over the transition period up to 1st August 2005 he will gradually relinquish his current functions as Group Leader within the AB Department.

  20. Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: A comparative study on Phantom and cadaver head scans

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); University Hospital Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Schoellchen, Maximilian; Hanken, H.; Precht, C.; Heiland, M. [University Medical Center Hamburg, Department of Oral- and Maxillofacial Surgery, Hamburg (Germany); Henes, F.O.; Adam, G.; Regier, M. [University Medical Center Hamburg, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Schoen, G. [University Medical Center Hamburg, Department of Medical Biometry and Epidemiology, Hamburg (Germany); Nagel, H.D. [Science and Technology for Radiology, Buchholz (Germany); Schumacher, U. [University Medical Center Hamburg, Institute of Anatomy, Hamburg (Germany)

    2017-02-15

    To compare multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) regarding radiation, resolution, image noise, and image quality. CBCT and 256-MDCT were compared based on three scan protocols: Standard-dose (∼24 mGy), reduced-dose (∼9 mGy), and low-dose (∼4 mGy). MDCT images were acquired in standard- and high-resolution mode (HR-MDCT) and reconstructed using filtered back projection (FBP) and iterative reconstruction (IR). Spatial resolution in linepairs (lp) and objective image noise (OIN) were assessed using dedicated phantoms. Image quality was assessed in scans of 25 cadaver heads using a Likert scale. OIN was markedly higher in FBP-MDCT when compared to CBCT. IR lowered the OIN to comparable values in standard-mode MDCT only. CBCT provided a resolution of 13 lp/cm at standard-dose and 11 lp/cm at reduced-dose vs. 11 lp/cm and 10 lp/cm in HR-MDCT. Resolution of 10 lp/cm was observed for both devices using low-dose settings. Quality scores of MDCT and CBCT did not differ at standard-dose (CBCT, 3.4; MDCT, 3.3-3.5; p > 0.05). Using reduced- and low-dose protocols, CBCT was superior (reduced-dose, 3.2 vs. 2.8; low dose, 3.0 vs. 2.3; p < 0.001). Using the low-dose protocol, the assessed CBCT provided better objective and subjective image quality and equality in resolution. Similar image quality, but better resolution using CBCT was observed at higher exposure settings. (orig.)

  1. Human Papilloma Virus (HPV) Induced Head & Neck Squamous Cell Carcinoma: A Comprehensive Retrospect

    Science.gov (United States)

    Nishat, Roquaiya; Ramachandra, Sujatha; Kumar, Harish; Bandyopadhyay, Alokenath

    2015-01-01

    Head and Neck Squamous Cell Carcinoma accounts for the sixth most common malignancy occurring worldwide with tobacco and alcohol being the two well established risk factors. In the recent years, substantial evidence has been obtained that Human Papilloma Virus (HPV) associated head and neck cancers are on the rise. This article provides an insight into the structure of HPV genome, molecular pathogenesis, detection methods and clinical implications of HPV positive Head and Neck Squamous Cell Carcinoma. PMID:26266234

  2. A structurally detailed finite element human head model for simulation of transcranial magnetic stimulation.

    Science.gov (United States)

    Chen, Ming; Mogul, David Jeffery

    2009-04-30

    Computational studies of the head utilizing finite element models (FEMs) have been used to investigate a wide variety of brain-electromagnetic (EM) field interaction phenomena including magnetic stimulation of the head using transcranial magnetic stimulation (TMS), direct electric stimulation of the brain for electroconvulsive therapy, and electroencephalography source localization. However, no human head model of sufficient complexity for studying the biophysics under these circumstances has been developed which utilizes structures at both the regional and cellular levels and provides well-defined smooth boundaries between tissues of different conductivities and orientations. The main barrier for building such accurate head models is the complex modeling procedures that include 3D object reconstruction and optimized meshing. In this study, a structurally detailed finite element model of the human head was generated that includes details to the level of cerebral gyri and sulci by combining computed tomography and magnetic resonance images. Furthermore, cortical columns that contain conductive processes of pyramidal neurons traversing the neocortical layers were included in the head model thus providing structure at or near the cellular level. These refinements provide a much more realistic model to investigate the effects of TMS on brain electrophysiology in the neocortex.

  3. A New Electromagnetic Navigation System for Pedicle Screws Placement: A Human Cadaver Study at the Lumbar Spine.

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    Full Text Available Technical developments for improving the safety and accuracy of pedicle screw placement play an increasingly important role in spine surgery. In addition to the standard techniques of free-hand placement and fluoroscopic navigation, the rate of complications is reduced by 3D fluoroscopy, cone-beam CT, intraoperative CT/MRI, and various other navigation techniques. Another important aspect that should be emphasized is the reduction of intraoperative radiation exposure for personnel and patient. The aim of this study was to investigate the accuracy of a new navigation system for the spine based on an electromagnetic field.Twenty pedicle screws were placed in the lumbar spine of human cadavers using EMF navigation. Navigation was based on data from a preoperative thin-slice CT scan. The cadavers were positioned on a special field generator and the system was matched using a patient tracker on the spinous process. Navigation was conducted using especially developed instruments that can be tracked in the electromagnetic field. Another thin-slice CT scan was made postoperatively to assess the result. The evaluation included the position of the screws in the direction of trajectory and any injury to the surrounding cortical bone. The results were classified in 5 groups: grade 1: ideal screw position in the center of the pedicle with no cortical bone injury; grade 2: acceptable screw position, cortical bone injury with cortical penetration ≤ 2 mm; grade 3: cortical bone injury with cortical penetration 2,1-4 mm, grad 4: cortical bone injury with cortical penetration 4,1-6 mm, grade 5: cortical bone injury with cortical penetration >6 mm.The initial evaluation of the system showed good accuracy for the lumbar spine (65% grade 1, 20% grade 2, 15% grade 3, 0% grade 4, 0% grade 5. A comparison of the initial results with other navigation techniques in literature (CT navigation, 2D fluoroscopic navigation shows that the accuracy of this system is

  4. Introduction of a fresh cadaver laboratory during the surgery clerkship improves emergency technical skills.

    Science.gov (United States)

    Nematollahi, Saman; Kaplan, Stephen J; Knapp, Christopher M; Ho, Hang; Alvarado, Jared; Viscusi, Rebecca; Adamas-Rappaport, William

    2015-08-01

    Student acquisition of technical skills during the clinical years of medical school has been steadily declining. To address this issue, the authors instituted a fresh cadaver-based Emergency Surgical Skills Laboratory (ESSL). Sixty-three medical students rotating through the third-year surgery clerkship participated in a 2-hour, fresh cadaver-based ESSL conducted during the first 2 days of the clerkship. The authors evaluated students utilizing both surgical skills and written examination before the ESSL and at 4 weeks post ESSL. Students demonstrated a mean improvement of 64% (±11) (P cadaver laboratory is an effective method to provide proficiency in emergency technical skills not acquired during the clinical years of medical school. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Mapping the Articular Contact Area of the Long Head of the Biceps Tendon on the Humeral Head

    Directory of Open Access Journals (Sweden)

    Brent J. Morris

    2014-01-01

    Full Text Available The purpose of this investigation was to calculate the contact surface area of the long head of the biceps (LHB in neutral position and abduction. We sought to determine whether the LHB articulates with the humeral head in a consistent pattern comparing articular contact area in neutral position and abduction. Eleven fresh frozen matched cadaveric shoulders were analyzed. The path of the biceps tendon on the articular surface of the humeral head and the total articular surface were digitized using a MicronTracker 2 H3-60 three-dimensional optical tracker. Contact surface area was significantly less in abduction than in neutral position (P=0.002 with a median ratio of 41% (36%, 47.5%. Ratios of contact area in neutral position to full articular surface area were consistent between left and right shoulders (rho=1, P=0.017 as were ratios of abduction area to full articular surface area (rho= 0.97, P=0.005. The articular contact surface area is significantly greater in neutral position than abduction. The ratios of articular contact surface areas to total humeral articular surface areas have a narrow range and are consistent between left and right shoulders of the same cadaver.

  6. How to decrease the emotional impact of cadaver dissection in medical students

    Directory of Open Access Journals (Sweden)

    F Javadnia

    2009-03-01

    Full Text Available Background: Teaching anatomy is based on cadaver dissection. Working  with cadavers, whether through active dissection or by examination of prosected specimens, constitutes a potential stressor in medical  education.Purpose.To reduce the anxiety of the medical students by mentally preparing them before going to the dissection room.Methods: The questionnaires were distributed among 68 medical students. The pre-dissection questionnaire comprised questions related to demographic data and the first encounter with a cadaver. The students were randomly divided into experimental and control groups. The experimental group was prepared psychologically prior to dissection, but the control group entered the dissection room without any preparation. After the first dissection class, all students were surveyed by the second questionnaire  which surveyed physical and cognitive symptoms of anxiety, resulting from exposure to the dissection room at the first visit and six weeks later.Results: There was a significant difference (p<.05 in the rate of anxiety between experimental and control group in the initial visit. The difference in the rate of anxiety between the first exposure and six weeks later was significant in control group (p<.008, while it was not significant in the experimental group.Conclusion: The initial preparation could relatively reduce the rate of stress, so that the experimental group experienced less errs tonal effects during dissection compared to control group.Keyword: Emotional impact, cadaver dissection, medical students

  7. Blood flow and microdialysis in the human femoral head

    DEFF Research Database (Denmark)

    Bøgehøj, Morten; Emmeluth, Claus; Overgaard, Søren

    2007-01-01

    BACKGROUND: If it would be possible to detect lack of flow and/or the development of ischemia in bone, we might have a way of predicting whether a broken bone will heal. We established microdialysis (MD) and laser Doppler (LD) flow measurement in the human femoral head in order to be able to detect...

  8. Intrathecal volume changes in lumbar spinal canal stenosis following extension and flexion: An experimental cadaver study.

    Science.gov (United States)

    Teske, Wolfram; Schwert, Martin; Zirke, Sonja; von Schulze Pellengahr, Christoph; Wiese, Matthias; Lahner, Matthias

    2015-01-01

    The spinal canal stenosis is a common disease in elderly. The thecal sac narrowing is considered as the anatomical cause for the disease. There is evidence that the anatomical proportions of the lumbar spinal canal are influenced by postural changes. The liquor volume shift during these postural changes is a valuable parameter to estimate the dynamic qualities of this disease. The aim of this human cadaver study was the determination of intrathecal fluid volume changes during the lumbar flexion and the extension. A special measuring device was designed and built for the study to investigate this issue under controlled conditions. The measuring apparatus fixed the lumbar spine firmly and allowed only flexion and extension. The dural sac was closed water tight. The in vitro changes of the intrathecal volumes during the motion cycle were determined according to the principle of communicating vessels. Thirteen human cadaver spines from the Institute of Anatomy were examined in a test setting with a continuous adjustment of motion. The diagnosis of the lumbar spinal stenosis was confirmed by a positive computer tomography prior testing. The volume changes during flexion and extension cycles were measured stepwise in a 2 degree distance between 18° flexion and 18° extension. Three complete series of measurements were performed for each cadaver. Two specimens were excluded because of fluid leaks from further investigation. The flexion of the lumbar spine resulted in an intrathecal volume increase. The maximum volume effects were seen in the early flexion positions of 2° and 4°. The spine reclination resulted in a volume reduction. The maximum extension effect was seen between 14° and 16°. According to our results, remarkable volume effects were seen in the early movements of the lumbar spine especially for the flexion. The results support the concept of the spinal stenosis as a dynamic disease and allow a better understanding of the pathophysiology of this

  9. Current Status of Cadaver Sources in Turkey and a Wake-Up Call for Turkish Anatomists

    Science.gov (United States)

    Gürses, Ilke Ali; Coskun, Osman; Öztürk, Adnan

    2018-01-01

    Persisting difficulties in body procurement in Turkey led to the acquisition of donated, unclaimed, autopsied, and imported bodies regulated under current legislature. Yet, no study had investigated the extent of the on-going cadaver problem. This study was aimed to outline cadaver sources in anatomy departments and their effectiveness by means of…

  10. Autopsy experience with a radioactive cadaver

    International Nuclear Information System (INIS)

    Johnston, A.S.; Minarcik, J.; Rossi, R.; Pinsky, S.

    1979-01-01

    A patient who received a 200-mCi dose of 131 I for widespread carcinoma died 10 days after treatment with 50 mCi remaining in the cadaver. An autopsy was required. The radiation levels were sufficiently high that personnel radiation protection was needed. An autopsy procedure was designed that prevented ingestion of radioactivity by the pathologist and his assistants, prevented excessive exposure of any involved personnel, and prevented contamination of the autopsy room or other hospital space. (author)

  11. Friction of ceramic and metal hip hemi-endoprostheses against cadaveric acetabula.

    Science.gov (United States)

    Müller, L P; Degreif, J; Rudig, L; Mehler, D; Hely, H; Rommens, P M

    2004-12-01

    Studies of hip arthroplasty have dealt mainly with total endoprosthesis, while tribology measurement values of hemi-endoprosthetic implants are rare. The small amount of experimental tribological data concerning materials of hemi-endoprosthetic implants in the form of pendulum trials, animal experiments, in vivo measurements on human hip joints and pin on disc studies report friction coefficients between 0.014 and 0.57; the friction coefficients measured in fresh human cadaver hip joints were determined between 0.001 and 0.08. The HEPFlEx-hip simulator was constructed to test the friction coefficients of unipolar femur head hemi-endoprostheses made of metal or ceramic against fresh cadaveric acetabula. Its plane of movement is uniaxial with a flexion-extension movement of +30/-18 degrees . The force is produced pneumatically dynamic with amounts of 2.5 kN. Newborn calf serum serves as a lubricant. We mounted 20 fresh porcine acetabula and 10 fresh human cadaver acetabula in the HEPFlEx-hip simulator and compared the two unipolar femur head hemi-endoprostheses (metal vs. ceramic). The mean friction coefficients against porcine acetabula were micro=0.017-0.082 for ceramic and micro=0.020-0.101 for metal; against human cadaver acetabula micro=0.017-0.083 for ceramic and micro=0.019-0.118 for metal. The frictional coefficient deltas (metal-ceramic) values of all measurements were Deltamicro=0.004 for porcine acetabula and Deltamicro=0.001 for cadaver acetabula. Box-plots graphics document significantly lower frictional coefficients of the ceramics. The lower frictional coefficients of ceramic compared to metal against fresh cadaveric acetabula may have a clinical impact on the process of the protrusion of the corresponding femoral head through the acetabulum.

  12. A novel semi-automatic snake robot for natural orifice transluminal endoscopic surgery: preclinical tests in animal and human cadaver models (with video).

    Science.gov (United States)

    Son, Jaebum; Cho, Chang Nho; Kim, Kwang Gi; Chang, Tae Young; Jung, Hyunchul; Kim, Sung Chun; Kim, Min-Tae; Yang, Nari; Kim, Tae-Yun; Sohn, Dae Kyung

    2015-06-01

    Natural orifice transluminal endoscopic surgery (NOTES) is an emerging surgical technique. We aimed to design, create, and evaluate a new semi-automatic snake robot for NOTES. The snake robot employs the characteristics of both a manual endoscope and a multi-segment snake robot. This robot is inserted and retracted manually, like a classical endoscope, while its shape is controlled using embedded robot technology. The feasibility of a prototype robot for NOTES was evaluated in animals and human cadavers. The transverse stiffness and maneuverability of the snake robot appeared satisfactory. It could be advanced through the anus as far as the peritoneal cavity without any injury to adjacent organs. Preclinical tests showed that the device could navigate the peritoneal cavity. The snake robot has advantages of high transverse force and intuitive control. This new robot may be clinically superior to conventional tools for transanal NOTES.

  13. 'Goats that stare at men': dwarf goats alter their behaviour in response to human head orientation, but do not spontaneously use head direction as a cue in a food-related context.

    Science.gov (United States)

    Nawroth, Christian; von Borell, Eberhard; Langbein, Jan

    2015-01-01

    Recently, comparative research on the mechanisms and species-specific adaptive values of attributing attentive states and using communicative cues has gained increased interest, particularly in non-human primates, birds, and dogs. Here, we investigate these phenomena in a farm animal species, the dwarf goat (Capra aegagrus hircus). In the first experiment, we investigated the effects of different human head and body orientations, as well as human experimenter presence/absence, on the behaviour of goats in a food-anticipating paradigm. Over a 30-s interval, the experimenter engaged in one of four different postures or behaviours (head and body towards the subject-'Control', head to the side, head and body away from the subject, or leaving the room) before delivering a reward. We found that the level of subjects' active anticipatory behaviour was highest in the control condition and decreased with a decreasing level of attention paid to the subject by the experimenter. Additionally, goats 'stared' (i.e. stood alert) at the experimental set-up for significantly more time when the experimenter was present but paid less attention to the subject ('Head' and 'Back' condition) than in the 'Control' and 'Out' conditions. In a second experiment, the experimenter provided different human-given cues that indicated the location of a hidden food reward in a two-way object choice task. Goats were able to use both 'Touch' and 'Point' cues to infer the correct location of the reward but did not perform above the level expected by chance in the 'Head only' condition. We conclude that goats are able to differentiate among different body postures of a human, including head orientation; however, despite their success at using multiple physical human cues, they fail to spontaneously use human head direction as a cue in a food-related context.

  14. Coupled Physical and Digital Cadaver Dissection Followed by a Visual Test Protocol Provides Insights into the Nature of Anatomical Knowledge and Its Evaluation

    Science.gov (United States)

    Hisley, Kenneth C.; Anderson, Larry D.; Smith, Stacy E.; Kavic, Stephen M.; Tracy, J. Kathleen

    2008-01-01

    This research effort compared and contrasted two conceptually different methods for the exploration of human anatomy in the first-year dissection laboratory by accomplished students: "physical" dissection using an embalmed cadaver and "digital" dissection using three-dimensional volume modeling of whole-body CT and MRI image sets acquired using…

  15. Development of a desiccated cadaver delivery system to apply entomopathogenic nematodes for control of soil pests

    Science.gov (United States)

    Pentomopathogenic nematodes may be more capable of controlling soil pests when they are harbored by desiccated cadavers. A small-scale system was developed from a modified crop seed planter to effectively deliver desiccated nematode-infected cadavers into the soil. The system mainly consists of a me...

  16. [Proposed difficult airway teaching methodology. Presentation of an interactive fresh frozen cadaver model].

    Science.gov (United States)

    Catalá Bauset, J C; de Andres Ibañez, J A; Valverde Navarro, A; Martinez Soriano, F

    2014-04-01

    The aim of this paper is to present a methodology based on the use of fresh-frozen cadavers for training in the management of the airway, and to evaluate the degree of satisfaction among learning physicians. About 6 fresh-frozen cadavers and 14 workstations were prepared where participants were trained in the different skills needed for airway management. The details of preparation of the cadavers are described. The level of satisfaction of the participant was determined using a Likert rating scale of 5 points, at each of the 14 stations, as well as the overall assessment and clinical usefulness of the course. The mean overall evaluation of the course and its usefulness was 4.75 and 4.9, out of 5, respectively. All parts of the course were rated above 4 out of 5. The high level of satisfaction of the course remained homogeneous in the 2 editions analysed. The overall satisfaction of the course was not finally and uniquely determined by any of its particular parts. The fresh cadaver model for training physicians in techniques of airway management is a proposal satisfactory to the participant, and with a realism that approaches the live patient. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  17. Simulated training in colonoscopic stenting of colonic strictures: validation of a cadaver model.

    Science.gov (United States)

    Iordache, F; Bucobo, J C; Devlin, D; You, K; Bergamaschi, R

    2015-07-01

    There are currently no available simulation models for training in colonoscopic stent deployment. The aim of this study was to validate a cadaver model for simulation training in colonoscopy with stent deployment for colonic strictures. This was a prospective study enrolling surgeons at a single institution. Participants performed colonoscopic stenting on a cadaver model. Their performance was assessed by two independent observers. Measurements were performed for quantitative analysis (time to identify stenosis, time for deployment, accuracy) and a weighted score was devised for assessment. The Mann-Whitney U-test and Student's t-test were used for nonparametric and parametric data, respectively. Cohen's kappa coefficient was used for reliability. Twenty participants performed a colonoscopy with deployment of a self-expandable metallic stent in two cadavers (groups A and B) with 20 strictures overall. The median time was 206 s. The model was able to differentiate between experts and novices (P = 0. 013). The results showed a good consensus estimate of reliability, with kappa = 0.571 (P cadaver model described in this study has content, construct and concurrent validity for simulation training in colonoscopic deployment of self-expandable stents for colonic strictures. Further studies are needed to evaluate the predictive validity of this model in terms of skill transfer to clinical practice. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  18. Comparative evaluation of the cadaveric, radiographic and computed tomographic anatomy of the heads of green iguana (Iguana iguana), common tegu (Tupinambis merianae) and bearded dragon (Pogona vitticeps).

    Science.gov (United States)

    Banzato, Tommaso; Selleri, Paolo; Veladiano, Irene A; Martin, Andrea; Zanetti, Emanuele; Zotti, Alessandro

    2012-05-11

    Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of: 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (-20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any imaging modality involving these

  19. Comparative evaluation of the cadaveric, radiographic and computed tomographic anatomy of the heads of green iguana (Iguana iguana) , common tegu ( Tupinambis merianae) and bearded dragon ( Pogona vitticeps)

    Science.gov (United States)

    2012-01-01

    Background Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. Results 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of : 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (−20°C) until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. Conclusions The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be useful in interpreting any

  20. Comparative evaluation of the cadaveric, radiographic and computed tomographic anatomy of the heads of green iguana (Iguana iguana , common tegu ( Tupinambis merianae and bearded dragon ( Pogona vitticeps

    Directory of Open Access Journals (Sweden)

    Banzato Tommaso

    2012-05-01

    Full Text Available Abstract Background Radiology and computed tomography are the most commonly available diagnostic tools for the diagnosis of pathologies affecting the head and skull in veterinary practice. Nevertheless, accurate interpretation of radiographic and CT studies requires a thorough knowledge of the gross and the cross-sectional anatomy. Despite the increasing success of reptiles as pets, only a few reports over their normal imaging features are currently available. The aim of this study is to describe the normal cadaveric, radiographic and computed tomographic features of the heads of the green iguana, tegu and bearded dragon. Results 6 adult green iguanas, 4 tegus, 3 bearded dragons, and, the adult cadavers of : 4 green iguana, 4 tegu, 4 bearded dragon were included in the study. 2 cadavers were dissected following a stratigraphic approach and 2 cadavers were cross-sectioned for each species. These latter specimens were stored in a freezer (−20°C until completely frozen. Transversal sections at 5 mm intervals were obtained by means of an electric band-saw. Each section was cleaned and photographed on both sides. Radiographs of the head of each subject were obtained. Pre- and post- contrast computed tomographic studies of the head were performed on all the live animals. CT images were displayed in both bone and soft tissue windows. Individual anatomic structures were first recognised and labelled on the anatomic images and then matched on radiographs and CT images. Radiographic and CT images of the skull provided good detail of the bony structures in all species. In CT contrast medium injection enabled good detail of the soft tissues to be obtained in the iguana whereas only the eye was clearly distinguishable from the remaining soft tissues in both the tegu and the bearded dragon. Conclusions The results provide an atlas of the normal anatomical and in vivo radiographic and computed tomographic features of the heads of lizards, and this may be

  1. Pulmonary Complications of Mustard Gas Exposure: A Study on Cadavers

    Directory of Open Access Journals (Sweden)

    Behnam Behnoush

    2011-04-01

    Full Text Available Sulfur mustard gas is one of the chemical warfare gases that roughly about 45000 soldiers continue to suffer long-lasting consequences of exposure during the Iran-Iraq war between 1980 and 1988. According to the common pulmonary lesions due to this gas exposure, we studied gross and microscopic pulmonary lesions in cadavers and also assessed the main causes of mortality caused by mustard gas exposure. A case-series study was performed on hospital record files of 100 cadavers that were exposed with documented sulfur mustard gas during the Iran-Iraq war from 1979 to 1988 and autopsied in legal medicine organization In Tehran between 2005 and 2007 and gross and microscopic pathological findings of autopsied organs such as hematological, pulmonary, hepatic, and renal changes were evaluated. All cases were male with the mean age of 43 years. The time interval between the gas exposure and death was almost 20years. The most frequent pulmonary complication was chronic bronchitis in 81% of autopsied cadavers. Other pulmonary findings were progressive pulmonary fibrosis (9%, pulmonary infections and tuberculosis (29%, malignant cellular infiltration (4%, and aspergilloma (1%. According to the chronic progressive lesions caused by mustard gas exposure such as pulmonary lesions and also its high mortality rate, suitable programming for protection of the gas exposed persons and prohibiting chemical warfare are recommended.

  2. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  3. Anatomic Assessment of Variations in Kambin's Triangle: A Surgical and Cadaver Study.

    Science.gov (United States)

    Ozer, Ali Fahir; Suzer, Tuncer; Can, Halil; Falsafi, Mani; Aydin, Murat; Sasani, Mehdi; Oktenoglu, Tunc

    2017-04-01

    The relationship of exiting root and Kambin's triangle is discussed in this article. Transforaminal endoscopic surgery as the gold standard of less invasive lumbar disc surgeries is performed through Kambin's triangle. Existing root damage is one of the most important complication for this type of surgery. Anatomic variations in Kambin's triangle may be the main reason for nerve root damage during endoscopic lumbar disc surgery. Kambin's triangle was investigated with surgical views and cadaver studies. Thirty-four patients with far lateral disc herniation were treated with an extraforaminal approach under the microscope. On the other hand, 48 Kambin's triangles were dissected on 8 cadavers. Three main types of triangle were identified, and patients were grouped according to these 3 types of the triangle. Only 6 of the 34 patients had type 3 triangles, which is the wide classical triangle described by Kambin; however, 17 patients had type 2, with a narrow space in the triangle, and 11 patients had type 1, with no space inside the triangle. Cadaver results were similar; only 10 of the 48 specimens had the type 3 classical triangle, whereas 23 specimens had type 2, and 15 specimens had type 1 triangles. Our results disclosed narrowed or no space in 82.4% of the patients and 79.2% of the cadavers. We observed that a wide and safe room of the triangle may not be exist in some patients. Therefore, more care must be taken during endoscopic lumbar disc surgery to avoid nerve damage. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. The Omental Pedicle Flap in Dogs Revised and Refined: A Cadaver Study.

    Science.gov (United States)

    Doom, Marjan; Cornillie, Pieter; Simoens, Paul; Huyghe, Stephanie; de Rooster, Hilde

    2016-08-01

    To expand current knowledge on the canine omental vasculature and refine the existing lengthening technique of the canine omentum. Ex vivo study. Canine cadavers (n=20). In 10 canine cadavers the omental arteries were mapped using intravascular latex injection and these results were used to create an omental pedicle flap based on the splenic artery in 10 additional cadavers. The operating range of the flap was recorded with particular attention to the main regions of interest for omental transposition in dogs (axillary and inguinal regions). The superficial and deep omental leaves were each predominantly supplied by a left and a right marginal omental artery that anastomosed near the caudal omental border into a superficial and a deep omental arch, respectively. Anastomoses between arteries of the superficial and the deep omental leaves were weak and inconsistent, except for 1 anastomosis that was found in 8 of 10 dogs. By transposing the intact omentum, the right axilla could be reached in 3 dogs, both axillae in 1 dog, and both groins in all cadavers. In all cases, the omental pedicle reached to and beyond the axillary and inguinal regions. By unfolding the pedicle leaves, the width of the pedicle tip could be doubled. When lengthening the omentum is necessary to reach extra-abdominal structures, the omental pedicle flap based on the splenic artery appears to preserve the omental vascular supply. These observations warrant further clinical trials to evaluate this new omtental flap technique in vivo. © Copyright 2016 by The American College of Veterinary Surgeons.

  5. Human Papillomavirus Induced Transformation in Cervical and Head and Neck Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Allie K. [Cancer and Blood Diseases Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229 (United States); Wise-Draper, Trisha M. [Division of Hematology/Oncology, University of Cincinnati Medical Center, University of Cincinnati, Cincinnati, OH 45229 (United States); Wells, Susanne I., E-mail: Susanne.Wells@cchmc.org [Cancer and Blood Diseases Institute, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH 45229 (United States)

    2014-09-15

    Human papillomavirus (HPV) is one of the most widely publicized and researched pathogenic DNA viruses. For decades, HPV research has focused on transforming viral activities in cervical cancer. During the past 15 years, however, HPV has also emerged as a major etiological agent in cancers of the head and neck, in particular squamous cell carcinoma. Even with significant strides achieved towards the screening and treatment of cervical cancer, and preventive vaccines, cervical cancer remains the leading cause of cancer-associated deaths for women in developing countries. Furthermore, routine screens are not available for those at risk of head and neck cancer. The current expectation is that HPV vaccination will prevent not only cervical, but also head and neck cancers. In order to determine if previous cervical cancer models for HPV infection and transformation are directly applicable to head and neck cancer, clinical and molecular disease aspects must be carefully compared. In this review, we briefly discuss the cervical and head and neck cancer literature to highlight clinical and genomic commonalities. Differences in prognosis, staging and treatment, as well as comparisons of mutational profiles, viral integration patterns, and alterations in gene expression will be addressed.

  6. Human Papillomavirus Induced Transformation in Cervical and Head and Neck Cancers

    International Nuclear Information System (INIS)

    Adams, Allie K.; Wise-Draper, Trisha M.; Wells, Susanne I.

    2014-01-01

    Human papillomavirus (HPV) is one of the most widely publicized and researched pathogenic DNA viruses. For decades, HPV research has focused on transforming viral activities in cervical cancer. During the past 15 years, however, HPV has also emerged as a major etiological agent in cancers of the head and neck, in particular squamous cell carcinoma. Even with significant strides achieved towards the screening and treatment of cervical cancer, and preventive vaccines, cervical cancer remains the leading cause of cancer-associated deaths for women in developing countries. Furthermore, routine screens are not available for those at risk of head and neck cancer. The current expectation is that HPV vaccination will prevent not only cervical, but also head and neck cancers. In order to determine if previous cervical cancer models for HPV infection and transformation are directly applicable to head and neck cancer, clinical and molecular disease aspects must be carefully compared. In this review, we briefly discuss the cervical and head and neck cancer literature to highlight clinical and genomic commonalities. Differences in prognosis, staging and treatment, as well as comparisons of mutational profiles, viral integration patterns, and alterations in gene expression will be addressed

  7. Evaluation of hands-on seminar for reduced port surgery using fresh porcine cadaver model

    Directory of Open Access Journals (Sweden)

    Saseem Poudel

    2016-01-01

    Full Text Available Background: The use of various biological and non-biological simulators is playing an important role in training modern surgeons with laparoscopic skills. However, there have been few reports of the use of a fresh porcine cadaver model for training in laparoscopic surgical skills. The purpose of this study was to report on a surgical training seminar on reduced port surgery using a fresh cadaver porcine model and to assess its feasibility and efficacy. Materials and Methods: The hands-on seminar had 10 fresh porcine cadaver models and two dry boxes. Each table was provided with a unique access port and devices used in reduced port surgery. Each group of 2 surgeons spent 30 min at each station, performing different tasks assisted by the instructor. The questionnaire survey was done immediately after the seminar and 8 months after the seminar. Results: All the tasks were completed as planned. Both instructors and participants were highly satisfied with the seminar. There was a concern about the time allocated for the seminar. In the post-seminar survey, the participants felt that the number of reduced port surgeries performed by them had increased. Conclusion: The fresh cadaver porcine model requires no special animal facility and can be used for training in laparoscopic procedures.

  8. Evaluation of hands-on seminar for reduced port surgery using fresh porcine cadaver model.

    Science.gov (United States)

    Poudel, Saseem; Kurashima, Yo; Shichinohe, Toshiaki; Kitashiro, Shuji; Kanehira, Eiji; Hirano, Satoshi

    2016-01-01

    The use of various biological and non-biological simulators is playing an important role in training modern surgeons with laparoscopic skills. However, there have been few reports of the use of a fresh porcine cadaver model for training in laparoscopic surgical skills. The purpose of this study was to report on a surgical training seminar on reduced port surgery using a fresh cadaver porcine model and to assess its feasibility and efficacy. The hands-on seminar had 10 fresh porcine cadaver models and two dry boxes. Each table was provided with a unique access port and devices used in reduced port surgery. Each group of 2 surgeons spent 30 min at each station, performing different tasks assisted by the instructor. The questionnaire survey was done immediately after the seminar and 8 months after the seminar. All the tasks were completed as planned. Both instructors and participants were highly satisfied with the seminar. There was a concern about the time allocated for the seminar. In the post-seminar survey, the participants felt that the number of reduced port surgeries performed by them had increased. The fresh cadaver porcine model requires no special animal facility and can be used for training in laparoscopic procedures.

  9. Perception to Cadaver Dissection and Views on Anatomy as a ...

    African Journals Online (AJOL)

    However, literature on medical students' perceptions on cadaver dissection and their ... Bachelor of Medicine and Bachelor of Surgery at the new school of Medicine, Kenya ... training and counseling to make the experience better for students.

  10. Navigation of Pedicle Screws in the Thoracic Spine with a New Electromagnetic Navigation System: A Human Cadaver Study

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    2015-01-01

    Full Text Available Introduction. Posterior stabilization of the spine is a standard procedure in spinal surgery. In addition to the standard techniques, several new techniques have been developed. The objective of this cadaveric study was to examine the accuracy of a new electromagnetic navigation system for instrumentation of pedicle screws in the spine. Material and Method. Forty-eight pedicle screws were inserted in the thoracic spine of human cadavers using EMF navigation and instruments developed especially for electromagnetic navigation. The screw position was assessed postoperatively by a CT scan. Results. The screws were classified into 3 groups: grade 1 = ideal position; grade 2 = cortical penetration <2 mm; grade 3 = cortical penetration ≥2 mm. The initial evaluation of the system showed satisfied positioning for the thoracic spine; 37 of 48 screws (77.1%, 95% confidence interval [62.7%, 88%] were classified as group 1 or 2. Discussion. The screw placement was satisfactory. The initial results show that there is room for improvement with some changes needed. The ease of use and short setup times should be pointed out. Instrumentation is achieved without restricting the operator’s mobility during navigation. Conclusion. The results indicate a good placement technique for pedicle screws. Big advantages are the easy handling of the system.

  11. Response of forest soil euglyphid testate amoebae (Rhizaria: Cercozoa) to pig cadavers assessed by high-throughput sequencing.

    Science.gov (United States)

    Seppey, Christophe V W; Fournier, Bertrand; Szelecz, Ildikò; Singer, David; Mitchell, Edward A D; Lara, Enrique

    2016-03-01

    Decomposing cadavers modify the soil environment, but the effect on soil organisms and especially on soil protists is still poorly documented. We conducted a 35-month experiment in a deciduous forest where soil samples were taken under pig cadavers, control plots and fake pigs (bags of similar volume as the pigs). We extracted total soil DNA, amplified the SSU ribosomal RNA (rRNA) gene V9 region and sequenced it by Illumina technology and analysed the data for euglyphid testate amoebae (Rhizaria: Euglyphida), a common group of protozoa known to respond to micro-environmental changes. We found 51 euglyphid operational taxonomic units (OTUs), 45 of which did not match any known sequence. Most OTUs decreased in abundance underneath cadavers between days 0 and 309, but some responded positively after a time lag. We sequenced the full-length SSU rRNA gene of two common OTUs that responded positively to cadavers; a phylogenetic analysis showed that they did not belong to any known euglyphid family. This study confirmed the existence of an unknown diversity of euglyphids and that they react to cadavers. Results suggest that metabarcoding of soil euglyphids could be used as a forensic tool to estimate the post-mortem interval (PMI) particularly for long-term (>2 months) PMI, for which no reliable tool exists.

  12. A Proposal for a Policy on the Ethical Care and Use of Cadavers and Their Tissues

    Science.gov (United States)

    Champney, Thomas H.

    2011-01-01

    Recent events have occurred that indicate the need for policies on the ethical care and use of cadavers and their tissues in the United States. At present, there are policies that address the procurement, handling and disposition of cadavers, but there are no national or society sponsored policies that clearly state the ethically appropriate use…

  13. Human Papilloma Virus Associated Squamous Cell Carcinoma of the Head and Neck

    OpenAIRE

    Ajila, Vidya; Shetty, Harish; Babu, Subhas; Shetty, Veena; Hegde, Shruthi

    2015-01-01

    Oral cancer is one of the commonest causes for mortality and morbidity with squamous cell carcinoma being the sixth most frequent malignant tumour worldwide. In addition to tobacco and alcohol, human papilloma virus (HPV) is associated with a proportion of head and neck cancers. As in cervical cancers, HPV types 16 and 18 are the cause of malignant transformation. HPV-positive cancers of head and neck have unique characteristics such as occurrence in a younger age group, distinct clinical and...

  14. Integration of visual and non-visual self-motion cues during voluntary head movements in the human brain.

    Science.gov (United States)

    Schindler, Andreas; Bartels, Andreas

    2018-05-15

    Our phenomenological experience of the stable world is maintained by continuous integration of visual self-motion with extra-retinal signals. However, due to conventional constraints of fMRI acquisition in humans, neural responses to visuo-vestibular integration have only been studied using artificial stimuli, in the absence of voluntary head-motion. We here circumvented these limitations and let participants to move their heads during scanning. The slow dynamics of the BOLD signal allowed us to acquire neural signal related to head motion after the observer's head was stabilized by inflatable aircushions. Visual stimuli were presented on head-fixed display goggles and updated in real time as a function of head-motion that was tracked using an external camera. Two conditions simulated forward translation of the participant. During physical head rotation, the congruent condition simulated a stable world, whereas the incongruent condition added arbitrary lateral motion. Importantly, both conditions were precisely matched in visual properties and head-rotation. By comparing congruent with incongruent conditions we found evidence consistent with the multi-modal integration of visual cues with head motion into a coherent "stable world" percept in the parietal operculum and in an anterior part of parieto-insular cortex (aPIC). In the visual motion network, human regions MST, a dorsal part of VIP, the cingulate sulcus visual area (CSv) and a region in precuneus (Pc) showed differential responses to the same contrast. The results demonstrate for the first time neural multimodal interactions between precisely matched congruent versus incongruent visual and non-visual cues during physical head-movement in the human brain. The methodological approach opens the path to a new class of fMRI studies with unprecedented temporal and spatial control over visuo-vestibular stimulation. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Web-based visualisation of head pose and facial expressions changes: monitoring human activity using depth data

    OpenAIRE

    Kalliatakis, Grigorios; Vidakis, Nikolaos; Triantafyllidis, Georgios

    2017-01-01

    Despite significant recent advances in the field of head pose estimation and facial expression recognition, raising the cognitive level when analysing human activity presents serious challenges to current concepts. Motivated by the need of generating comprehensible visual representations from different sets of data, we introduce a system capable of monitoring human activity through head pose and facial expression changes, utilising an affordable 3D sensing technology (Microsoft Kinect sensor)...

  16. Deoxycholic Acid and the Marginal Mandibular Nerve: A Cadaver Study.

    Science.gov (United States)

    Blandford, Alexander D; Ansari, Waseem; Young, Jason M; Maley, Bruce; Plesec, Thomas P; Hwang, Catherine J; Perry, Julian D

    2018-06-04

    One of the rare but serious complications observed with deoxycholic acid administration is damage to the marginal mandibular nerve. In this study, we evaluated if deoxycholic acid directly induces histologic damage to fresh cadaveric marginal mandibular nerve. A segment of marginal mandibular nerve was harvested from 12 hemifaces of 6 fresh cadavers. The nerve specimen was exposed to either 0.9% sterile saline for 24 h, deoxycholic acid (10 mg/ml) for 20 min, or deoxycholic acid (10 mg/ml) for 24 h. The nerve specimens were then fixed in glutaraldehyde for a minimum of 24 h. Toluidine blue stained sections were evaluated for stain intensity using light microscopy and color deconvolution image analysis. Supraplatysmal fat was harvested as a positive control and exposed to the same treatments as the marginal mandibular nerve specimens, then evaluated using transmission electron microscopy. Toluidine blue staining was less in the marginal mandibular nerve exposed to deoxycholic acid when compared to saline. The specimen exposed to deoxycholic acid for 24 h showed less toluidine blue staining than that of the nerve exposed to deoxycholic acid for 20 min. Transmission electron microscopy of submental fat exposed to deoxycholic acid revealed disruption of adipocyte cell membrane integrity and loss of cellular organelles when compared to specimens only exposed to saline. Deoxycholic acid (10 mg/ml) damages the marginal mandibular nerve myelin sheath in fresh human cadaver specimens. Direct deoxycholic acid neurotoxicity may cause marginal mandibular nerve injury clinically. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  17. Subchondral bone density distribution in the human femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Wright, David A.; Meguid, Michael; Lubovsky, Omri; Whyne, Cari M. [Sunnybrook Research Institute, Orthopaedic Biomechanics Laboratory, Toronto, Ontario (Canada)

    2012-06-15

    This study aims to quantitatively characterize the distribution of subchondral bone density across the human femoral head using a computed tomography derived measurement of bone density and a common reference coordinate system. Femoral head surfaces were created bilaterally for 30 patients (14 males, 16 females, mean age 67.2 years) through semi-automatic segmentation of reconstructed CT data and used to map bone density, by shrinking them into the subchondral bone and averaging the greyscale values (linearly related to bone density) within 5 mm of the articular surface. Density maps were then oriented with the center of the head at the origin, the femoral mechanical axis (FMA) aligned with the vertical, and the posterior condylar axis (PCA) aligned with the horizontal. Twelve regions were created by dividing the density maps into three concentric rings at increments of 30 from the horizontal, then splitting into four quadrants along the anterior-posterior and medial-lateral axes. Mean values for each region were compared using repeated measures ANOVA and a Bonferroni post hoc test, and side-to-side correlations were analyzed using a Pearson's correlation. The regions representing the medial side of the femoral head's superior portion were found to have significantly higher densities compared to other regions (p < 0.05). Significant side-to-side correlations were found for all regions (r {sup 2} = 0.81 to r {sup 2} = 0.16), with strong correlations for the highest density regions. Side-to-side differences in measured bone density were seen for two regions in the anterio-lateral portion of the femoral head (p < 0.05). The high correlation found between the left and right sides indicates that this tool may be useful for understanding 'normal' density patterns in hips affected by unilateral pathologies such as avascular necrosis, fracture, developmental dysplasia of the hip, Perthes disease, and slipped capital femoral head epiphysis. (orig.)

  18. The Living Dead: Bacterial Community Structure of a Cadaver at the Onset and End of the Bloat Stage of Decomposition

    OpenAIRE

    Hyde, Embriette R.; Haarmann, Daniel P.; Lynne, Aaron M.; Bucheli, Sibyl R.; Petrosino, Joseph F.

    2013-01-01

    Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphono...

  19. An Innovate Robotic Endoscope Guidance System for Transnasal Sinus and Skull Base Surgery: Proof of Concept.

    Science.gov (United States)

    Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J

    2017-12-01

    Objective  Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods  The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results  Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion  The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.

  20. Acoustic pressure waves induced in human heads by RF pulses from high-field MRI scanners.

    Science.gov (United States)

    Lin, James C; Wang, Zhangwei

    2010-04-01

    The current evolution toward greater image resolution from magnetic resonance image (MRI) scanners has prompted the exploration of higher strength magnetic fields and use of higher levels of radio frequencies (RFs). Auditory perception of RF pulses by humans has been reported during MRI with head coils. It has shown that the mechanism of interaction for the auditory effect is caused by an RF pulse-induced thermoelastic pressure wave inside the head. We report a computational study of the intensity and frequency of thermoelastic pressure waves generated by RF pulses in the human head inside high-field MRI and clinical scanners. The U.S. Food and Drug Administration (U.S. FDA) guides limit the local specific absorption rate (SAR) in the body-including the head-to 8 W kg(-1). We present results as functions of SAR and show that for a given SAR the peak acoustic pressures generated in the anatomic head model were essentially the same at 64, 300, and 400 MHz (1.5, 7.0, and 9.4 T). Pressures generated in the anatomic head are comparable to the threshold pressure of 20 mPa for sound perception by humans at the cochlea for 4 W kg(-1). Moreover, results indicate that the peak acoustic pressure in the brain is only 2 to 3 times the auditory threshold at the U.S. FDA guideline of 8 W kg(-1). Even at a high SAR of 20 W kg(-1), where the acoustic pressure in the brain could be more than 7 times the auditory threshold, the sound pressure levels would not be more than 17 db above threshold of perception at the cochlea.

  1. Brain response to primary blast wave using validated finite element models of human head and advanced combat helmet

    Directory of Open Access Journals (Sweden)

    Liying eZhang

    2013-08-01

    Full Text Available Blast-induced traumatic brain injury has emerged as a signature injury in combat casualty care. Present combat helmets are designed primarily to protect against ballistic and blunt impacts, but the current issue with helmets is protection concerning blasts. In order to delineate the blast wave attenuating capability of the Advanced Combat Helmet (ACH, a finite element (FE study was undertaken to evaluate the head response against blast loadings with and without helmet using a partially validated FE model of the human head and ACH. Four levels of overpressures (0.27-0.66 MPa from the Bowen’s lung iso-damage threshold curves were used to simulate blast insults. Effectiveness of the helmet with respect to head orientation was also investigated. The resulting biomechanical responses of the brain to blast threats were compared for human head with and without the helmet. For all Bowen’s cases, the peak intracranial pressures (ICP in the head ranged from 0.68-1.8 MPa in the coup cortical region. ACH was found to mitigate ICP in the head by 10-35%. Helmeted head resulted in 30% lower average peak brain strains and product of strain and strain rate. Among three blast loading directions with ACH, highest reduction in peak ICP (44% was due to backward blasts whereas the lowest reduction in peak ICP and brain strains was due to forward blast (27%. The biomechanical responses of a human head to primary blast insult exhibited directional sensitivity owing to the different geometry contours and coverage of the helmet construction and asymmetric anatomy of the head. Thus, direction-specific tolerances are needed in helmet design in order to offer omni-directional protection for the human head. The blasts of varying peak overpressures and durations that are believed to produce the same level of lung injury produce different levels of mechanical responses in the brain, and hence "iso-damage" curves for brain injury are likely different than the Bowen curves

  2. ANATOMICAL VARIATIONS OF THE GASTROCNEMIUS MUSCLE- A DISSECTION-BASED STUDY

    Directory of Open Access Journals (Sweden)

    Rajat Dutta Roy

    2017-11-01

    Full Text Available BACKGROUND In human, the bulk of the posterior compartment of the leg is formed by the gastrocnemius and the soleus muscle. The superficially-placed gastrocnemius is a bipennate muscle, but according to available literature, it exhibits numerous anatomical variations. The aim of the present study is to find out the anatomical variations of the gastrocnemius muscle in this part of Assam. MATERIALS AND METHODS The present study undertaken in the Department of Anatomy, Jorhat Medical College, from August 2014 to August 2017 included 30 lower limbs from 15 embalmed cadavers of known sexes. These cadavers were provided to the first year MBBS students for routine dissection procedure. After carrying out the dissection as per Cunningham’s Manual of Practical Anatomy, the gastrocnemius muscle was examined for its two heads of origin. Any accessory heads found were noted and recorded. RESULTS Out of the 30 lower limb specimens, 28 (93.33% limbs presented with the normal two-headed gastrocnemius muscle, while 2 (6.66% limbs (1 right and 1 left, presented with four-headed gastrocnemius muscle. Both these limbs belonged to male cadavers. CONCLUSION The precise knowledge of occurrence of multi-headed gastrocnemius muscle should be kept in mind, while performing myocutaneous flaps around the knee joint and also during limb salvage procedures or limb sparing surgery.

  3. Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers

    International Nuclear Information System (INIS)

    Kalender, W.A.; Wolf, H.; Suess, C.; Gies, M.; Greess, H.; Bautz, W.A.

    1999-01-01

    We investigated approaches to reducing the dose in CT without impairing image quality. Dose can be reduced for non-circular object cross-sections without a significant increase in noise if X-ray tube current is reduced at angular tube positions where the X-ray attenuation by the patients is small. We investigated different schemes of current modulation during tube rotation by simulation and phantom measurements. Both pre-programmed sinusoidal modulation functions and attenuation-based on-line control of the tube current were evaluated. All relevant scan parameters were varied, including constraints such as the maximum modulation amplitude. A circular, an elliptical and two oval water phantoms were used. Results were validated on six cadavers. Dose reduction of 10-45 % was obtained both in simulations and in measurements for the different non-circular phantom geometries and current modulation algorithms without an increase in pixel noise values. On-line attenuation-based control yielded higher reductions than modulation by a sinusoidal curve. The maximal dose reduction predicted by simulations could not be achieved due to limits in the modulation amplitude. In cadaver studies, a reduction of typically 20-40 % was achieved for the body and about 10 % for the head. Variations of our technique are possible; a slight increase in nominal tube current for high-attenuation projections combined with attenuation-based current modulation still yields significant dose reduction, but also a reduction in the structured noise that may obscure diagnostic details. We conclude that a significant reduction in dose can be achieved by tube current modulation without compromising image quality. Attenuation-based on-line control and a modulation amplitude of at least 90 % should be employed. (orig.)

  4. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO System: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Guoxin Fan

    Full Text Available Percutaneous transforaminal endoscopic discectomy (PTED usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence.This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO system in puncture reduction of PTED.Cadaver study.Comparative groups.HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A. Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B. On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C.At L4/L5 level, there was significant difference in puncture times between Group A and Group B (P0.05. There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05.Small-sample preclinical study.HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127.

  5. 3D printed reproductions of orbital dissections: a novel mode of visualising anatomy for trainees in ophthalmology or optometry.

    Science.gov (United States)

    Adams, Justin W; Paxton, Lisa; Dawes, Kathryn; Burlak, Kateryna; Quayle, Michelle; McMenamin, Paul G

    2015-09-01

    The teaching of human head, neck and orbital anatomy forms a critical part of undergraduate and postgraduate medical and allied health professional training, including optometry. While still largely grounded in cadaveric dissection, this method of instruction is constrained in some countries and regional areas by access to real human cadavers, costs of cadaver bequest programmes, health and safety of students and staff and the shortage of adequate time in modern curricula. Many candidates choosing a postgraduate pathway in ophthalmological training, such as those accepted into the Royal Colleges of Ophthalmology in the UK, Australia and New Zealand programmes and the American Academy of Ophthalmologists in the USA, are compelled as adult learners to revise or revisit human orbital anatomy, ocular anatomy and select areas of head and neck anatomy. These candidates are often then faced with the issue of accessing facilities with dissected human cadaveric material. In light of these difficulties, we developed a novel means of creating high-resolution reproductions of prosected human cadaver orbits suitable for education and training. 3D printed copies of cadaveric orbital dissections (superior, lateral and medial views) showing a range of anatomical features were created. These 3D prints offer many advantages over plastinated specimens as they are suitable for rapid reproduction and as they are not human tissue they avoid cultural and ethical issues associated with viewing cadaver specimens. In addition, they are suitable for use in the office, home, laboratory or clinical setting in any part of the world for patient and doctor education. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Analysis of two colliding fractionally damped spherical shells in modelling blunt human head impacts

    Science.gov (United States)

    Rossikhin, Yury A.; Shitikova, Marina V.

    2013-06-01

    The collision of two elastic or viscoelastic spherical shells is investigated as a model for the dynamic response of a human head impacted by another head or by some spherical object. Determination of the impact force that is actually being transmitted to bone will require the model for the shock interaction of the impactor and human head. This model is indended to be used in simulating crash scenarios in frontal impacts, and provide an effective tool to estimate the severity of effect on the human head and to estimate brain injury risks. The model developed here suggests that after the moment of impact quasi-longitudinal and quasi-transverse shock waves are generated, which then propagate along the spherical shells. The solution behind the wave fronts is constructed with the help of the theory of discontinuities. It is assumed that the viscoelastic features of the shells are exhibited only in the contact domain, while the remaining parts retain their elastic properties. In this case, the contact spot is assumed to be a plane disk with constant radius, and the viscoelastic features of the shells are described by the fractional derivative standard linear solid model. In the case under consideration, the governing differential equations are solved analytically by the Laplace transform technique. It is shown that the fractional parameter of the fractional derivative model plays very important role, since its variation allows one to take into account the age-related changes in the mechanical properties of bone.

  7. Disease in the Society: Infectious Cadavers Result in Collapse of Ant Sub-Colonies

    Science.gov (United States)

    Loreto, Raquel G.; Hughes, David P.

    2016-01-01

    Despite the growing number of experimental studies on mechanisms of social immunity in ant societies, little is known about how social behavior relates to disease progression within the nests of ants. In fact, when empirically studying disease in ant societies, it is common to remove dead ants from experiments to confirm infection by the studied parasite. This unfortunately does not allow disease to progress within the nest as it may be assumed would happen under natural conditions. Therefore, the approach taken so far has resulted in a limited knowledge of diseases dynamics within the nest environment. Here we introduced a single infectious cadaver killed by the fungus Beauveria bassiana into small nests of the ant Camponotus castaneus. We then observed the natural progression of the disease by not removing the corpses of the ants that died following the first entry of the disease. Because some behaviors such as social isolation of sick individuals or the removal of cadavers by nestmates are considered social immune functions and thus adaptations at the colony level that reduce disease spread, we also experimentally confined some sub-colonies to one or two chamber nests to prevent the expression of such behaviors. Based on 51 small nests and survival studies in 1,003 ants we found that a single introduced infectious cadaver was able to transmit within the nest, and social immunity did not prevent the collapse of the small sub-colonies here tested. This was true whether ants did or did not have the option to remove the infectious cadaver. Therefore, we found no evidence that the typically studied social immunity behaviors can reduce disease spread in the conditions here tested. PMID:27529548

  8. A Study Of EMR And SAR Distribution In Human Head Phantom ...

    African Journals Online (AJOL)

    power of 0.32W for both simulations were well below the limit of 1.6 W/kg of ICNIRP standard and FCC/IEEE standard of 2W/kg. Keywords: Electromagnetic radiation (EMR), Specific Absorption Rate (SAR), Electromagnetic simulation software (FEKO emss), Radio frequency field, human head, mobile phone, mobile phone ...

  9. A Novel Instrumented Human Head Surrogate for the Impact Evaluation of Helmets

    Directory of Open Access Journals (Sweden)

    Nicola Petrone

    2018-02-01

    Full Text Available A novel Human Head Surrogate was obtained from available MRI scans of a 50th percentile male human head. Addictive manufacturing was used to produce the skull, the brain and the skin. All original MRI geometries were partially smoothed and adjusted to provide the best biofidelity compatible with printing and molding technology. The skull was 3D-printed in ABS and ten pressure sensors were placed into it. The brain surrogate was cast from silicon rubber in the 3D-printed plastic molds. Nine tri-axial accelerometers (placed at the tops of the lobes, at the sides of the lobes, in the cerebellum and in the center of mass and a three-axis gyroscope (at the center of mass were inserted into the silicon brain during casting. The cranium, after assembly with brain, was filled with silicon oil mimicking the cerebral fluid. Silicon rubber was cast in additional 3D-printed molds to form the skin surrounding the cranium. The skull base was adapted to be compatible with the Hybrid-III neck and allow the exit of brain sensors cabling. Preliminary experiments were carried out proving the functionality of the surrogate. Results showed how multiple accelerometers and pressure sensors allowed a better comprehension of the head complex motion during impacts.

  10. A comparison of a traditional endotracheal tube versus ETView SL in endotracheal intubation during different emergency conditions: A randomized, crossover cadaver trial.

    Science.gov (United States)

    Truszewski, Zenon; Krajewski, Paweł; Fudalej, Marcin; Smereka, Jacek; Frass, Michael; Robak, Oliver; Nguyen, Bianka; Ruetzler, Kurt; Szarpak, Lukasz

    2016-11-01

    Airway management is a crucial skill essential to paramedics and personnel working in Emergency Medical Services and Emergency Departments: Lack of practice, a difficult airway, or a trauma situation may limit the ability of paramedics to perform direct laryngoscopy during cardiopulmonary resuscitation. Videoscope devices are alternatives for airway management in these situations. The ETView VivaSight SL (ETView; ETView Ltd., Misgav, Israel) is a new, single-lumen airway tube with an integrated high-resolution imaging camera. To assess if the ETView VivaSight SL can be a superior alternative to a standard endotracheal tube for intubation in an adult cadaver model, both during and without simulated CPR. ETView VivaSight SL tube was investigated via an interventional, randomized, crossover, cadaver study. A total of 52 paramedics participated in the intubation of human cadavers in three different scenarios: a normal airway at rest without concomitant chest compression (CC) (scenario A), a normal airway with uninterrupted CC (scenario B) and manual in-line stabilization (scenario C). Time and rate of success for intubation, the glottic view scale, and ease-of-use of ETView vs. sETT intubation were assessed for each emergency scenario. The median time to intubation using ETView vs. sETT was compared for each of the aforementioned scenarios. For scenario A, time to first ventilation was achieved fastest for ETView, 19.5 [IQR, 16.5-22] sec, when compared to that of sETT at 21.5 [IQR, 20-25] sec (p = .013). In scenario B, the time for intubation using ETView was 21 [IQR, 18.5-24.5] sec (p cadavers and the time to ventilation were improved with the ETView. The time to glottis view, tube insertion, and cuff block were all found to be shorter with the ETView. clinicaltrials.gov Identifier: NCT02733536.

  11. Break with tradition: donating cadavers for scientific purposes and reducing the use of sentient beings.

    Science.gov (United States)

    Ciliberti, Rosagemma; Martini, Mariano; Bonsignore, Alessandro; Penco, Susanna

    2016-01-01

    In recent years, the development of research and the increased awareness of our moral duties beyond the human species have pushed the scientific community to revise widely-accepted ontological reductionist views that regard non-human animals as mere things. The new horizons offered by the development of advanced research methods therefore require an on-going commitment to new perspectives able to find the right balance between the need for scientific knowledge on one hand and the respect for animal life on the other. This is in line with increasing attention to animal welfare and expansion of the "3Rs model": replacement, reduction, refinement.With the view of promoting the adoption of alternative methods, human body donation for research can contribute not only to the acquisition of important information for human health and for doctors' training, but also can reduce significantly the number of animals sacrificed.By investigating the scientific and ethical reasons that may encourage cadaver donation, the authors aim to promote the adoption of the practice in Italy following other European experiences.

  12. Acute Q fever infection in Thuringia, Germany, after burial of roe deer fawn cadavers (Capreolus capreolus: a case report

    Directory of Open Access Journals (Sweden)

    B.T. Schleenvoigt

    2015-11-01

    Full Text Available We report on a case of a 48-year-old man who presented with acute Q fever infection after burying two fawn cadavers (Capreolus capreolus. Recent outbreaks of Q fever in Europe have been traced back to intensive goat breeding units, sheep flocks in the proximity of highly populated urban areas or to farmed deer. To our knowledge, this is the first case report describing Q fever infection in a human linked to roe deer as a source of infection.

  13. The ultimate intrinsic signal-to-noise ratio of loop- and dipole-like current patterns in a realistic human head model.

    Science.gov (United States)

    Pfrommer, Andreas; Henning, Anke

    2018-03-13

    The ultimate intrinsic signal-to-noise ratio (UISNR) represents an upper bound for the achievable SNR of any receive coil. To reach this threshold a complete basis set of equivalent surface currents is required. This study systematically investigated to what extent either loop- or dipole-like current patterns are able to reach the UISNR threshold in a realistic human head model between 1.5 T and 11.7 T. Based on this analysis, we derived guidelines for coil designers to choose the best array element at a given field strength. Moreover, we present ideal current patterns yielding the UISNR in a realistic body model. We distributed generic current patterns on a cylindrical and helmet-shaped surface around a realistic human head model. We excited electromagnetic fields in the human head by using eigenfunctions of the spherical and cylindrical Helmholtz operator. The electromagnetic field problem was solved by a fast volume integral equation solver. At 7 T and above, adding curl-free current patterns to divergence-free current patterns substantially increased the SNR in the human head (locally >20%). This was true for the helmet-shaped and the cylindrical surface. On the cylindrical surface, dipole-like current patterns had high SNR performance in central regions at ultra-high field strength. The UISNR increased superlinearly with B0 in most parts of the cerebrum but only sublinearly in the periphery of the human head. The combination of loop and dipole elements could enhance the SNR performance in the human head at ultra-high field strength. © 2018 International Society for Magnetic Resonance in Medicine.

  14. Learning Anatomy through Thiel- vs. Formalin-Embalmed Cadavers: Student Perceptions of Embalming Methods and Effect on Functional Anatomy Knowledge

    Science.gov (United States)

    Kennel, Larissa; Martin, David M. A.; Shaw, Hannah; Wilkinson, Tracey

    2018-01-01

    Thiel-embalmed cadavers, which have been adopted for use in anatomy teaching in relatively few universities, show greater flexibility and color retention compared to formalin-embalmed cadavers, properties which might be considered advantageous for anatomy teaching. This study aimed to investigate student attitudes toward the dissection experience…

  15. Effectiveness of isopropyl myristate/cyclomethicone D5 solution of removing cuticular hydrocarbons from human head lice (Pediculus humanus capitis

    Directory of Open Access Journals (Sweden)

    Barnett Eric

    2012-09-01

    Full Text Available Abstract Background In the treatment of human head lice infestation, healthcare providers are increasingly concerned about lice becoming resistant to existing pesticide treatments. Traditional pesticides, used to control these pests, have a neurological mechanism of action. This publication describes a topical solution with a non-traditional mechanism of action, based on physical disruption of the wax layer that covers the cuticle of the louse exoskeleton. This topical solution has been shown clinically to cure 82% of patients with only a 10-minute treatment time, repeated once after 7 days. All insects, including human head lice, have a wax-covered exoskeleton. This wax, composed of hydrocarbons, provides the insect with protection against water loss and is therefore critical to its survival. When the protective wax is disrupted, water loss becomes uncontrollable and irreversible, leading to dehydration and death. A specific pattern of hydrocarbons has been found in all of the head louse cuticular wax studied. Iso-octane effectively removes these hydrocarbons from human head lice’s cuticular wax. Methods A method of head louse cuticle wax extraction and analysis by gas chromatography was developed. Human head lice (Pediculus humanus capitis were collected from infested patients and subjected to any of three extraction solvents comprising either the test product or one of two solvents introduced as controls. A gas chromatograph equipped with a flame ionization detector (GC/FID was used to determine the presence of hydrocarbons in the three head lice extracts. Results In the study reported herein, the test product isopropyl myristate/cyclomethicone D5 (IPM/D5 was shown to perform comparably with iso-octane, effectively extracting the target hydrocarbons from the cuticular wax that coats the human head louse exoskeleton. Conclusions Disruption of the integrity of the insect cuticle by removal of specific hydrocarbons found in the cuticular wax

  16. Intraosseous vascular access through the anterior mandible--a cadaver model pilot study.

    Directory of Open Access Journals (Sweden)

    Christin Goldschalt

    Full Text Available BACKGROUND: Several insertion sites have been described for intraosseous puncture in cases of emergencies when a conventional vascular access cannot be established. This pilot study has been designed to evaluate the feasibility of the mandibular bone for the use of an intraosseous vascular access in a cadaver model. METHODOLOGY/PRINCIPAL FINDINGS: 17 dentistry and 16 medical students participating in a voluntary course received a short introduction into the method and subsequently used the battery powered EZ-IO system with a 15 mm cannula for a puncture of the anterior mandible in 33 cadavers. The time needed to perform each procedure was evaluated. India ink was injected into the accesses and during the anatomy course cadavers were dissected to retrace the success or failure of the puncture. Dental students needed 25.5±18.9(mean±standard deviations and medical students 33±20.4 s for the procedure (p = 0.18. Floor of mouth extravasation occurred in both groups in 3 cases. Success rates were 82 and 75% (p = 0.93. CONCLUSIONS/SIGNIFICANCE: Despite floor of mouth extravasation of injected fluid into a mandibular intraosseous access might severely complicate this procedure, the anterior mandible may be helpful as an alternative to other intraosseous and intravenous insertion sites when these are not available in medical emergencies.

  17. Eyewear Computing – Augmenting the Human with Head-mounted Wearable Assistants (Dagstuhl Seminar 16042)

    OpenAIRE

    Bulling, Andreas; Cakmakci, Ozan; Kunze, Kai; Rehg, James M.

    2016-01-01

    The seminar was composed of workshops and tutorials on head-mounted eye tracking, egocentric vision, optics, and head-mounted displays. The seminar welcomed 30 academic and industry researchers from Europe, the US, and Asia with a diverse background, including wearable and ubiquitous computing, computer vision, developmental psychology, optics, and human-computer interaction. In contrast to several previous Dagstuhl seminars, we used an ignite talk format to reduce the time of talks to...

  18. Effect of cell-phone radiofrequency on angiogenesis and cell invasion in human head and neck cancer cells.

    Science.gov (United States)

    Alahmad, Yaman M; Aljaber, Mohammed; Saleh, Alaaeldin I; Yalcin, Huseyin C; Aboulkassim, Tahar; Yasmeen, Amber; Batist, Gerald; Moustafa, Ala-Eddin Al

    2018-05-13

    Today, the cell phone is the most widespread technology globally. However, the outcome of cell-phone radiofrequency on head and neck cancer progression has not yet been explored. The chorioallantoic membrane (CAM) and human head and neck cancer cell lines, FaDu and SCC25, were used to explore the outcome of cell-phone radiofrequency on angiogenesis, cell invasion, and colony formation of head and neck cancer cells, respectively. Western blot analysis was used to investigate the impact of the cell phone on the regulation of E-cadherin and Erk1/Erk2 genes. Our data revealed that cell-phone radiofrequency promotes angiogenesis of the CAM. In addition, the cell phone enhances cell invasion and colony formation of human head and neck cancer cells; this is accompanied by a downregulation of E-cadherin expression. More significantly, we found that the cell phone can activate Erk1/Erk2 in our experimental models. Our investigation reveals that cell-phone radiofrequency could enhance head and neck cancer by stimulating angiogenesis and cell invasion via Erk1/Erk2 activation. © 2018 Wiley Periodicals, Inc.

  19. SimLife a new model of simulation using a pulsated revascularized and reventilated cadaver for surgical education.

    Science.gov (United States)

    Delpech, P O; Danion, J; Oriot, D; Richer, J P; Breque, C; Faure, J P

    2017-02-01

    Alike becoming a pilot requires competences, acquisition of technical skills is essential to become a surgeon. Halsted's theory on surgical education "See one, do one, and teach one" is not currently compatible with the reality of socio-economic constraints of the operating room, the patient's safety demand and the reduction of residents' work hours. In all countries, this brings mandatory to simulation education for surgery resident's training. Many models are available: video trainers or pelvi-trainers, computed simulator, animal models or human cadaver… Human cadaveric dissection has long been used to teach surgical anatomy. Surgery on human cadaveric model brings greatest accuracy to the haptic characteristics of surgical procedures. Learning in an appropriate and realistic simulation context increases the level of acquisition of the residents' skills and reduces stress and anxiety when performing real procedures. We present a technique of perfusion and ventilation of a fresh human cadaver that restores pulsatile circulation and respiratory movements of the model. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Learning anatomy through Thiel- vs. formalin-embalmed cadavers: Student perceptions of embalming methods and effect on functional anatomy knowledge.

    Science.gov (United States)

    Kennel, Larissa; Martin, David M A; Shaw, Hannah; Wilkinson, Tracey

    2018-03-01

    Thiel-embalmed cadavers, which have been adopted for use in anatomy teaching in relatively few universities, show greater flexibility and color retention compared to formalin-embalmed cadavers, properties which might be considered advantageous for anatomy teaching. This study aimed to investigate student attitudes toward the dissection experience with Thiel- compared to formalin/ethanol-embalmed cadavers. It also aimed to determine if one embalming method is more advantageous in terms of learning functional anatomy through the comparison of student anterior forearm functional anatomy knowledge. Student opinions and functional anatomy knowledge were obtained through use of a questionnaire from students at two medical schools, one using Thiel-, and one using more traditional formalin/ethanol-embalmed cadavers. Both the Thiel group and the formalin group of students were surveyed shortly after completing an anterior forearm dissection session. Significant differences (P-values <0.01) in some attitudes were found toward the dissection experience between cohorts using Thiel- vs. formalin-embalmed cadavers. The Thiel group of students felt more confident about recognizing anatomy in the living individual, found it easier to identify and dissect anatomical structures, and indicated more active exploration of functional anatomy due to the retained flexibility of the cadaver. However, on testing, no significant difference in functional anatomy knowledge was found between the two cohorts. Overall, although Thiel embalming may provide an advantageous learning experience in some investigated areas, more research needs to be carried out, especially to establish whether student perception is based on reality, at least in terms of structure identification. Anat Sci Educ 11: 166-174. © 2017 American Association of Anatomists. © 2017 American Association of Anatomists.

  1. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

    Science.gov (United States)

    Fan, Guoxin; Guan, Xiaofei; Sun, Qi; Hu, Annan; Zhu, Yanjie; Gu, Guangfei; Zhang, Hailong; He, Shisheng

    2015-01-01

    Percutaneous transforaminal endoscopic discectomy (PTED) usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence. This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO) system in puncture reduction of PTED. Cadaver study. Comparative groups. HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A). Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B). On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C). At L4/L5 level, there was significant difference in puncture times between Group A and Group B (PHELLO system reduced 39%-45% radiation dosage when comparing Group A and Group B, but there was no significant difference in radiation exposure between Group A and Group C whatever at L4/L5 level or L5/S1 level (P>0.05). There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05). Small-sample preclinical study. HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127).

  2. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    Science.gov (United States)

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (pcadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical

  3. The Living Dead: Bacterial Community Structure of a Cadaver at the Onset and End of the Bloat Stage of Decomposition

    Science.gov (United States)

    Hyde, Embriette R.; Haarmann, Daniel P.; Lynne, Aaron M.; Bucheli, Sibyl R.; Petrosino, Joseph F.

    2013-01-01

    Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphonomy and readily attributed to microbial physiology, was targeted. Each cadaver was sampled at two time points, at the onset and end of the bloat stage, from various body sites including internal locations. Bacterial samples were analyzed by pyrosequencing of the 16S rRNA gene. Our data show a shift from aerobic bacteria to anaerobic bacteria in all body sites sampled and demonstrate variation in community structure between bodies, between sample sites within a body, and between initial and end points of the bloat stage within a sample site. These data are best not viewed as points of comparison but rather additive data sets. While some species recovered are the same as those observed in culture-based studies, many are novel. Our results are preliminary and add to a larger emerging data set; a more comprehensive study is needed to further dissect the role of bacteria in human decomposition. PMID:24204941

  4. The living dead: bacterial community structure of a cadaver at the onset and end of the bloat stage of decomposition.

    Science.gov (United States)

    Hyde, Embriette R; Haarmann, Daniel P; Lynne, Aaron M; Bucheli, Sibyl R; Petrosino, Joseph F

    2013-01-01

    Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphonomy and readily attributed to microbial physiology, was targeted. Each cadaver was sampled at two time points, at the onset and end of the bloat stage, from various body sites including internal locations. Bacterial samples were analyzed by pyrosequencing of the 16S rRNA gene. Our data show a shift from aerobic bacteria to anaerobic bacteria in all body sites sampled and demonstrate variation in community structure between bodies, between sample sites within a body, and between initial and end points of the bloat stage within a sample site. These data are best not viewed as points of comparison but rather additive data sets. While some species recovered are the same as those observed in culture-based studies, many are novel. Our results are preliminary and add to a larger emerging data set; a more comprehensive study is needed to further dissect the role of bacteria in human decomposition.

  5. The living dead: bacterial community structure of a cadaver at the onset and end of the bloat stage of decomposition.

    Directory of Open Access Journals (Sweden)

    Embriette R Hyde

    Full Text Available Human decomposition is a mosaic system with an intimate association between biotic and abiotic factors. Despite the integral role of bacteria in the decomposition process, few studies have catalogued bacterial biodiversity for terrestrial scenarios. To explore the microbiome of decomposition, two cadavers were placed at the Southeast Texas Applied Forensic Science facility and allowed to decompose under natural conditions. The bloat stage of decomposition, a stage easily identified in taphonomy and readily attributed to microbial physiology, was targeted. Each cadaver was sampled at two time points, at the onset and end of the bloat stage, from various body sites including internal locations. Bacterial samples were analyzed by pyrosequencing of the 16S rRNA gene. Our data show a shift from aerobic bacteria to anaerobic bacteria in all body sites sampled and demonstrate variation in community structure between bodies, between sample sites within a body, and between initial and end points of the bloat stage within a sample site. These data are best not viewed as points of comparison but rather additive data sets. While some species recovered are the same as those observed in culture-based studies, many are novel. Our results are preliminary and add to a larger emerging data set; a more comprehensive study is needed to further dissect the role of bacteria in human decomposition.

  6. Laser-driven short-duration heating angioplasty: dilatation performance in cadaver atherosclerotic femoral arteries

    Science.gov (United States)

    Shimazaki, Natsumi; Naruse, Sho; Arai, Tsunenori; Imanishi, Nobuaki; Aiso, Sadakazu

    2013-03-01

    The purpose of this study was to investigate the artery dilatation performance of the short-duration heating balloon catheter in cadaver stenotic arteries. We designed a prototype short-duration heating balloon catheter that can heat artery media to around 60 °C in 15-25 s by a combination of laser-driven heat generation and continuous fluid irrigation in the balloon. We performed ex vivo short-duration heating dilatation in the cadaver atherosclerotic femoral arteries (initial percent diameter stenosis was 36-98%), with the maximum balloon temperature of 65+/-5 °C, laser irradiation duration of 25 s, and balloon dilatation pressure of 3.5 atm. The artery lumen configurations before and after the dilatations were assessed with a commercial IVUS system. After the short-duration heating dilatations, the percent diameter stenosis was reduced below 30% without any artery tears or dissections. We estimated that the artery media temperature was raised to around 60 °C in which plaque thickness was below 0.8 mm by a thermal conduction calculation. The estimated maximum temperature in artery adventitia and surrounding tissue was up to 45 °C. We found that the short-duration heating balloon could sufficiently dilate the cadaver stenotic arteries, without thermal injury in artery adventitia and surroundings.

  7. Field Distribution of Transcranial Static Magnetic Stimulation in Realistic Human Head Model.

    Science.gov (United States)

    Tharayil, Joseph J; Goetz, Stefan M; Bernabei, John M; Peterchev, Angel V

    2017-10-10

    The objective of this work was to characterize the magnetic field (B-field) that arises in a human brain model from the application of transcranial static magnetic field stimulation (tSMS). The spatial distribution of the B-field magnitude and gradient of a cylindrical, 5.08 cm × 2.54 cm NdFeB magnet were simulated in air and in a human head model using the finite element method and calibrated with measurements in air. The B-field was simulated for magnet placements over prefrontal, motor, sensory, and visual cortex targets. The impact of magnetic susceptibility of head tissues on the B-field was quantified. Peak B-field magnitude and gradient respectively ranged from 179-245 mT and from 13.3-19.0 T/m across the cortical targets. B-field magnitude, focality, and gradient decreased with magnet-cortex distance. The variation in B-field strength and gradient across the anatomical targets largely arose from the magnet-cortex distance. Head magnetic susceptibilities had negligible impact on the B-field characteristics. The half-maximum focality of the tSMS B-field ranged from 7-12 cm 3 . This is the first presentation and characterization of the three-dimensional (3D) spatial distribution of the B-field generated in a human brain model by tSMS. These data can provide quantitative dosing guidance for tSMS applications across various cortical targets and subjects. The finding that the B-field gradient is high near the magnet edges should be considered in studies where neural tissue is placed close to the magnet. The observation that susceptibility has negligible effects confirms assumptions in the literature. © 2017 International Neuromodulation Society.

  8. Kinematics of the human mandible for different head postures.

    Science.gov (United States)

    Visscher, C M; Huddleston Slater, J J; Lobbezoo, F; Naeije, M

    2000-04-01

    The influence of head posture on movement paths of the incisal point (IP) and of the mandibular condyles during free open-close movements was studied. Ten persons, without craniomandibular or cervical spine disorders, participated in the study. Open close mandibular movements were recorded with the head in five postures, viz., natural head posture, forward head posture, military posture, and lateroflexion to the right and to the left side, using the Oral Kinesiologic Analysis System (OKAS-3D). This study showed that in a military head posture, the opening movement path of the incisal point is shifted anteriorly relative to the path in a natural head posture. In a forward head posture, the movement path is shifted posteriorly whereas during lateroflexion, it deviates to the side the head has moved to. Moreover, the intra-articular distance in the temporomandibular joint during closing is smaller with the head in military posture and greater in forward head posture, as compared to the natural head posture. During lateroflexion, the intra-articular distance on the ipsilateral side is smaller. The influence of head posture upon the kinematics of the mandible is probably a manifestation of differences in mandibular loading in the different head postures.

  9. Analysis of SAR distribution in human head of antenna used in wireless power transform based on magnetic resonance.

    Science.gov (United States)

    Gong, Feixiang; Wei, Zhiqiang; Cong, Yanping; Chi, Haokun; Yin, Bo; Sun, Mingui

    2017-07-20

    In this paper, a novel wireless power transfer antenna system was designed for human head implantable devices. The antenna system used the structure of three plates and four coils and operated at low frequencies to transfer power via near field. In order to verify the electromagnetic radiation safety on the human head, the electromagnetic intensity and specific absorption rate (SAR) were studied by finite-difference-time-domain (FDTD) method. A three-layer model of human head including skin, bone and brain tissues was constructed. The transmitting and receiving antenna were set outside and inside the model. The local and average SAR were simulated at the resonance frequency of 18.67 MHz in two situations, in one scenario both transmitting and receiving coil worked, while in the other scenario only the transmitting coil worked. The results showed that the maximum of 10 g SAR average value of human thoracic were 0.142 W/kg and 0.148 W/kg, respectively, both were lower than the international safety standards for human body of the ICNIRP and FCC, which verified the safety of the human body in wireless power transmission based on magnetic coupling resonance.

  10. Heads of household programme in Argentina: a human rights-based policy?

    Science.gov (United States)

    Colina, Jorge; Giordano, Osvaldo; Torres, Alejandra; Cárdenas, Marcelo

    2009-01-01

    This study analyses the consultative councils (CC) of the Argentinian conditional cash transfer heads of household programme as an institutional innovation directed to put into practice some of the principles of the human rights' approach for eradicating poverty. Since the main responsibilities assigned to the CCs coincided with some of the main principles of the human rights' approach, the research is focused on how CCs responded in practice. Using a case study methodology we show that even when, in theory, the CCs incorporate some of the principles of the human rights' approach to the programme, they deviated from this purpose due to a persistent phenomenon in the social policy arena in developing countries: political clientelism. Policy recommendations are formulated in order to deal with clientelism in the framework of the human rights' approach.

  11. Correlations Between the Autolytic Changes and Postmortem Interval in Refrigerated Cadavers

    Directory of Open Access Journals (Sweden)

    Cocariu Ela Andra

    2016-06-01

    Full Text Available Introduction. In forensic pathology the autolytic process has been observed and documented in order to determine the postmortem interval as accurately as possible. The observation and experiments have been carried out on cadavers exposed to environmental conditions – heat, humidity, air currents, soil, water.

  12. Toolbox of assessment tools of technical skills in otolaryngology-head and neck surgery: A systematic review.

    Science.gov (United States)

    Labbé, Mathilde; Young, Meredith; Nguyen, Lily H P

    2017-10-08

    To support the development of programs of assessment of technical skills in the operating room (OR), we systematically reviewed the literature to identify assessment tools specific to otolaryngology-head and neck surgery (OTL-HNS) core procedures and summarized their characteristics. We systematically searched Embase, MEDLINE, PubMed, and Cochrane to identify and report on assessment tools that can be used to assess residents' technical surgical skills in the operating room for OTL-HNS core procedures. Of the 736 unique titles retrieved, 16 articles met inclusion criteria, covering 11 different procedures (in otology, rhinology, laryngology, head and neck, and general otolaryngology). The tools were composed of a task-specific checklist and/or global rating scale and were developed in the OR, on human cadavers, or in a simulation setting. Our study reports on published tools for assessing technical skills for OTL-HNS residents during core procedures conducted in the OR. These assessment tools could facilitate the provision of timely feedback to trainees including specific goals for improvement. However, the paucity of publications suggests little agreement on how to best perform work-based direct-observation assessment for core surgical procedures in OTL-HNS. The sparsity of tools specific to OTL-HNS may become a barrier to a fluid transition to competency-based medical education. Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Transoral robotic surgery in head and neck cancer.

    Science.gov (United States)

    Hans, S; Delas, B; Gorphe, P; Ménard, M; Brasnu, D

    2012-02-01

    Robots have invaded industry and, more recently, the field of medicine. Following the development of various prototypes, Intuitive Surgical® has developed the Da Vinci surgical robot. This robot, designed for abdominal surgery, has been widely used in urology since 2000. The many advantages of this transoral robotic surgery (TORS) are described in this article. Its disadvantages are essentially its high cost and the absence of tactile feedback. The first feasibility studies in head and neck cancer, conducted in animals, dummies and cadavers, were performed in 2005, followed by the first publications in patients in 2006. The first series including more than 20 patients treated by TORS demonstrated the feasibility for the following sites: oropharynx, supraglottic larynx and hypopharynx. However, these studies did not validate the oncological results of the TORS technique. TORS decreases the number of tracheotomies, and allows more rapid swallowing rehabilitation and a shorter length of hospital stay. Technical improvements are expected. Smaller, more ergonomic, new generation robots, therefore more adapted to the head and neck, will probably be available in the future. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  14. Biomechanical Analysis of Human Abdominal Impact Responses and Injuries through Finite Element Simulations of a Full Human Body Model.

    Science.gov (United States)

    Ruan, Jesse S; El-Jawahri, Raed; Barbat, Saeed; Prasad, Priya

    2005-11-01

    Human abdominal response and injury in blunt impacts was investigated through finite element simulations of cadaver tests using a full human body model of an average-sized adult male. The model was validated at various impact speeds by comparing model responses with available experimental cadaver test data in pendulum side impacts and frontal rigid bar impacts from various sources. Results of various abdominal impact simulations are presented in this paper. Model-predicted abdominal dynamic responses such as force-time and force-deflection characteristics, and injury severities, measured by organ pressures, for the simulated impact conditions are presented. Quantitative results such as impact forces, abdominal deflections, internal organ stresses have shown that the abdomen responded differently to left and right side impacts, especially in low speed impact. Results also indicated that the model exhibited speed sensitive response characteristics and the compressibility of the abdomen significantly influenced the overall impact response in the simulated impact conditions. This study demonstrates that the development of a validated finite element human body model can be useful for abdominal injury assessment. Internal organ injuries, which are difficult to detect in experimental studies with human cadavers due to the difficulty of instrumentation, may be more easily identified with a validated finite element model through stress-strain analysis.

  15. Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations.

    Science.gov (United States)

    Thurtell, M J; Black, R A; Halmagyi, G M; Curthoys, I S; Aw, S T

    1999-05-01

    Vertical eye position-dependence of the human vestibuloocular reflex during passive and active yaw head rotations. The effect of vertical eye-in-head position on the compensatory eye rotation response to passive and active high acceleration yaw head rotations was examined in eight normal human subjects. The stimuli consisted of brief, low amplitude (15-25 degrees ), high acceleration (4,000-6,000 degrees /s2) yaw head rotations with respect to the trunk (peak velocity was 150-350 degrees /s). Eye and head rotations were recorded in three-dimensional space using the magnetic search coil technique. The input-output kinematics of the three-dimensional vestibuloocular reflex (VOR) were assessed by finding the difference between the inverted eye velocity vector and the head velocity vector (both referenced to a head-fixed coordinate system) as a time series. During passive head impulses, the head and eye velocity axes aligned well with each other for the first 47 ms after the onset of the stimulus, regardless of vertical eye-in-head position. After the initial 47-ms period, the degree of alignment of the eye and head velocity axes was modulated by vertical eye-in-head position. When fixation was on a target 20 degrees up, the eye and head velocity axes remained well aligned with each other. However, when fixation was on targets at 0 and 20 degrees down, the eye velocity axis tilted forward relative to the head velocity axis. During active head impulses, the axis tilt became apparent within 5 ms of the onset of the stimulus. When fixation was on a target at 0 degrees, the velocity axes remained well aligned with each other. When fixation was on a target 20 degrees up, the eye velocity axis tilted backward, when fixation was on a target 20 degrees down, the eye velocity axis tilted forward. The findings show that the VOR compensates very well for head motion in the early part of the response to unpredictable high acceleration stimuli-the eye position- dependence of the

  16. Human papilloma virus infection in head and neck cancer.

    Science.gov (United States)

    Tribius, Silke; Hoffmann, Markus

    2013-03-01

    The causal link between cervical cancer and human papilloma virus (HPV) is well known. It is now becoming clear that some types of squamous-cell carcinoma of the head and neck, particularly oropharyngeal carcinoma (OPC), are also linked to HPV infection. The development of vaccines against certain HPV genotypes has changed the management strategy for HPV-associated diseases of the uterine cervix. An analogous approach is now being considered for the prevention of HPV-associated diseases of the head and neck. We review pertinent articles retrieved by a selective search of the literature for phase II and III trials providing evidence about a possible effect of HPV status on the survival rates of patients with OPC. Seven trials fulfilled our search criteria: four phase III trials with retrospective HPV analysis and three phase II trials with retrospective and prospective HPV analysis. Patients with HPV-positive OPC survive significantly longer than those with HPV-negative OPC. Tobacco smoking has been identified as a negative prognostic factor in patients with either HPV-negative or HPV-positive disease. The established treatment strategy for OPC in patients with and without the traditional risk factors (tobacco and alcohol consumption) is now being reconsidered in the light of what we have learned about the role of HPV infection. Ongoing and projected clinical trials with risk-factor stratification may soon lead to changes in treatment. Further study is needed to answer the question whether HPV infection in the head and neck region is carcinogenic.

  17. Necropsy of a cadaver containing 50 mmCi of Na-131I

    International Nuclear Information System (INIS)

    Parthasarathy, K.L.; Komerek, M.; Quain, B.; Bakshi, S.P.; Qureshi, F.; Shimaoka, K.; Rao, U.; Adamski, J.S.; Bender, M.A.

    1982-01-01

    A patient who received an oral dose of 131 I for the treatment of metastatic thyroid carcinoma unexpectedly died with a large total-body retention of the radioiodine. An autopsy was required and the family requested the body to be transported out of state to their home town. Since the radiation intensity near the surface of the cadaver was above 200 mR/hr, advanced planning and special precautions were necessary in order for the autopsy to proceed safely. This required the immediate cooperation of the pathologists, nuclear medicine physicians, health physicists, an endocrine oncologist, and other hospital staff. As a result of team efforts, personnel radiation exposures were kept as low as reasonably achievable, contamination of the autopsy room was minimal, and the radiation level of the cadaver was adequately reduced for safe transport and burial

  18. Optimizing the Use of Cadavers by Integrating Pathology during Anatomy Dissection

    Science.gov (United States)

    Geldenhuys, Elsje-Márie; Burger, Elsie Helena; van Helden, Paul David; Mole, Calvin Gerald; Kotzé, Sanet Henriët

    2016-01-01

    An accurate knowledge of anatomy, especially natural variation within individuals, is of vital clinical importance. Cadaver dissection during anatomical training may be a valuable introduction to pathology for undergraduate students, which can contribute greatly to a successful medical career. The purpose of this study was to determine the extent…

  19. Anatomical variations of pronator teres muscle: predispositional role for nerve entrapment

    Directory of Open Access Journals (Sweden)

    Edie Benedito Caetano

    Full Text Available ABSTRACT OBJECTIVE: To assess the anatomical variations of the pronator teres muscle (PTM and its implication in the compression of the median nerve, which passes through the humeral and ulnar heads of the PTM. METHODS: For the present study, 100 upper limbs from human cadavers from the anatomy laboratory were dissected. Forty-six specimens were male and four, female, whose aged ranged from 28 to 77 years; 27 were white and 23, non-white. A pilot study consisting of six hands from three fresh cadaver dissections was conducted to familiarize the authors with the local anatomy; these were not included in the present study. RESULTS: The humeral and ulnar heads of PTM were present in 86 limbs. In 72 out of the 86 limbs, the median nerve was positioned between the two heads of the PTM; in 11, it passed through the muscle belly of ulnar head of the PTM, and in three, posteriorly to both heads of the PTM. When both heads were present, the median nerve was not observed as passing through the muscle belly of the humeral head of PTM. In 14 out of the 100 dissected limbs, the ulnar head of the PTM was not observed; in this situation, the median nerve was positioned posteriorly to the humeral head in 11 limbs, and passed through the humeral head in three. In 17 limbs, the ulnar head of PTM was little developed, with a fibrous band originating from the ulnar coronoid process, associated with a distal muscle component near the union with the humeral head. In four limbs, the ulnar head of the MPR was represented by a fibrous band. In both limbs of one cadaver, a fibrous band was observed between the supinator muscle and the humeral head of the PTM, passing over median nerve. CONCLUSION: The results suggest that these anatomical variations in relationship median nerve and PTM are potential factors for median nerve compression, as they narrow the space through which the median nerve passes.

  20. Diagnosis of Complex Pulley Ruptures Using Ultrasound in Cadaver Models.

    Science.gov (United States)

    Schöffl, Isabelle; Hugel, Arnica; Schöffl, Volker; Rascher, Wolfgang; Jüngert, Jörg

    2017-03-01

    Pulley ruptures are common in climbing athletes. The purposes of this study were to determine the specific positioning of each pulley with regards to the joint, and to evaluate the ultrasound diagnostics of various pulley rupture combinations. For this, 34 cadaver fingers were analyzed via ultrasound, the results of which were compared to anatomic measurements. Different pulley ruptures were then simulated and evaluated using ultrasound in standardized dynamic forced flexion. Visualization of the A2 and A4 pulleys was achieved 100% of the time, while the A3 pulley was visible in 74% of cases. Similarly, injuries to the A2 and A4 pulleys were readily observable, while A3 pulley injuries were more challenging to identify (sensitivity of 0.2 for singular A3 pulley, 0.5 for A2/A4 pulley and 0.33 for A3/A4 pulley ruptures). Receiver operating characteristic analysis was used to evaluate the optimal tendon-bone distance for pulley rupture diagnosis, a threshold which was determined to be 1.9 mm for A2 pulley ruptures and 1.85 for A4 pulley ruptures. This study was the first to carry out a cadaver ultrasound examination of a wide variety of pulley ruptures. Ultrasound is a highly accurate tool for visualizing the A2 and A4 pulleys in a cadaver model. This method of pathology diagnosis was determined to be suitable for injuries to the A2 and A4 pulleys, but inadequate for A3 pulley injuries. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. The science of shrinking human heads: tribal warfare and revenge among the South American Jivaro-Shuar.

    Science.gov (United States)

    Jandial, Rahul; Hughes, Samuel A; Aryan, Henry E; Marshall, Lawrence F; Levy, Michael L

    2004-11-01

    THE PRACTICE OF "head-shrinking" has been the proper domain not of Africa but rather of the denizens of South America. Specifically, in the post-Columbian period, it has been most famously the practice of a tribe of indigenous people commonly called the Jivaro or Jivaro-Shuar. The evidence suggests that the Jivaro-Shuar are merely the last group to retain a custom widespread in northwestern South America. In both ceramic and textile art of the pre-Columbian residents of Peru, the motif of trophy heads smaller than normal life-size heads commonly recurs; the motif is seen even in surviving carvings in stone and shell. Moreover, although not true shrunken heads, trophy heads found in late pre-Columbian and even post-Columbian graves of the region demonstrate techniques of display very similar to those used by the Jivaro-Shuar, at least some of which are best understood in the context of head-shrinking. Regardless, the Jivaro-Shuar and their practices provide an illustrative counterexample to popular myth regarding the culture and science of the shrinking of human heads.

  2. From fish to modern humans--comparative anatomy, homologies and evolution of the head and neck musculature.

    Science.gov (United States)

    Diogo, R; Abdala, V; Lonergan, N; Wood, B A

    2008-10-01

    In a recent paper Diogo (2008) reported the results of the first part of an investigation of the comparative anatomy, homologies and evolution of the head and neck muscles of osteichthyans (bony fish + tetrapods). That report mainly focused on actinopterygian fish, but also compared these fish with certain non-mammalian sarcopterygians. The present paper focuses mainly on sarcopterygians, and particularly on how the head and neck muscles have evolved during the transitions from sarcopterygian fish and non-mammalian tetrapods to monotreme and therian mammals, including modern humans. The data obtained from our dissections of the head and neck muscles of representative members of sarcopterygian fish, amphibians, reptiles, monotremes and therian mammals, such as rodents, tree-shrews, colugos and primates, including modern humans, are compared with the information available in the literature. Our observations and comparisons indicate that the number of mandibular and true branchial muscles (sensu this work) present in modern humans is smaller than that found in mammals such as tree-shrews, rats and monotremes, as well as in reptiles such as lizards. Regarding the pharyngeal musculature, there is an increase in the number of muscles at the time of the evolutionary transition leading to therian mammals, but there was no significant increase during the transition leading to the emergence of higher primates and modern humans. The number of hypobranchial muscles is relatively constant within the therian mammals we examined, although in this case modern humans have more muscles than other mammals. The number of laryngeal and facial muscles in modern humans is greater than that found in most other therian taxa. Interestingly, modern humans possess peculiar laryngeal and facial muscles that are not present in the majority of the other mammalian taxa; this seems to corroborate the crucial role played by vocal communication and by facial expressions in primate and especially in

  3. Do the radial head prosthesis components fit with the anatomical structures of the proximal radioulnar joint?

    Science.gov (United States)

    Wegmann, Kilian; Hain, Moritz K; Ries, Christian; Neiss, Wolfram F; Müller, Lars P; Burkhart, Klaus J

    2015-09-01

    The fitting accuracy of radial head components has been investigated in the capitulo-radial joint, and reduced contact after prosthetic replacement of the radial head has been observed. The kinematics of the proximal radioulnar joint (PRUJ) are affected by radial head arthroplasty as well, but have not yet been investigated in this regard. The elbow joints of 60 upper extremities of formalin-fixed body donors were disarticulated to obtain a good view of the PRUJ. Each specimen was mounted on the examining table and radial head position in the native PRUJ was assessed in neutral position, full pronation, and full supination. Measurements were repeated after implantation of mono- and bi-polar prostheses. Analysis of the distribution of the joint contacts in the compartments showed significant differences after radial head replacement. In comparison to the native joint, after bipolar and monopolar radial head replacement, the physiological shift of the proximal radius was altered. The physiological shift of the joint contact of the radial head from anterior to posterior during forearm rotation that was found in the native joint in our cadaver model was not observed after prosthetic replacement. With higher conformity and physiological kinematic of radial head prostheses, possibly lower shear forces and lower contact pressures would be generated. The tested radial head prostheses do not replicate the physiological kinematics of the radial head. Further development in the prosthesis design has to be made. The meticulous reconstruction of the annular ligament seems to be of importance to increase joint contact.

  4. Mechanized Packing and Delivery System for Entomopathogenic Nematodes in Infected Mealworm Cadavers

    Science.gov (United States)

    This document describes a mechanized system to pack mealworm (Tenebrio molitor) cadavers infected with entomopathogenic nematodes between two sheets of masking tape. The document is also an operation manual for the machine and provides all the machine specifications, and wiring and pneumatic diagram...

  5. Study of the Artroscopic Anatomy of the Knee in Canine Cadavers Using 2.4 Mm Diameter Lens

    Directory of Open Access Journals (Sweden)

    Gabriel Oswaldo Alonso Cuéllar

    2013-05-01

    Full Text Available Mainly by a limited access to new techniques and technologies, veterinary medicine in developing countries, has been far behind from the human medicine. One of the causes is the limited access to technology and specific techniques. Moreover, it is clear that many new technologies have proven their benefits in the two disciplines, making necessary and almost mandatory their massive implementation in humans and animals. The possibility to use human elements for veterinary techniques would improve the technology access and veterinarians training, at lower costs. The purpose of this study is to verify the feasibility to perform a knee arthroscopy in dogs with small human joints arthroscopic lenses. Under protocols established in veterinary 12 knee arthroscopies were performed in canine cadaver, using a wrist and ankle arthroscope human of 2.4 mm in diameter and 30° of angulation. All the structures reported in the literature were possible to visualize using a 2.4 mm arthroscope. In this sense, it is possible to develop training activities and subsequent implementation of endoscopic techniques in canine femorotibiopatellar joint, using a lens of small joints of human medicine.

  6. Averaged head phantoms from magnetic resonance images of Korean children and young adults

    Science.gov (United States)

    Han, Miran; Lee, Ae-Kyoung; Choi, Hyung-Do; Jung, Yong Wook; Park, Jin Seo

    2018-02-01

    Increased use of mobile phones raises concerns about the health risks of electromagnetic radiation. Phantom heads are routinely used for radiofrequency dosimetry simulations, and the purpose of this study was to construct averaged phantom heads for children and young adults. Using magnetic resonance images (MRI), sectioned cadaver images, and a hybrid approach, we initially built template phantoms representing 6-, 9-, 12-, 15-year-old children and young adults. Our subsequent approach revised the template phantoms using 29 averaged items that were identified by averaging the MRI data from 500 children and young adults. In females, the brain size and cranium thickness peaked in the early teens and then decreased. This is contrary to what was observed in males, where brain size and cranium thicknesses either plateaued or grew continuously. The overall shape of brains was spherical in children and became ellipsoidal by adulthood. In this study, we devised a method to build averaged phantom heads by constructing surface and voxel models. The surface model could be used for phantom manipulation, whereas the voxel model could be used for compliance test of specific absorption rate (SAR) for users of mobile phones or other electronic devices.

  7. The influence of gravity on regional lung blood flow in humans: SPECT in the upright and head-down posture.

    Science.gov (United States)

    Ax, M; Sanchez-Crespo, A; Lindahl, S G E; Mure, M; Petersson, J

    2017-06-01

    Previous studies in humans have shown that gravity has little influence on the distribution of lung blood flow while changing posture from supine to prone. This study aimed to evaluate the maximal influence of posture by comparison of regional lung blood flow in the upright and head-down posture in 8 healthy volunteers, using a tilt table. Regional lung blood flow was marked by intravenous injection of macroaggregates of human albumin labeled with 99m Tc or 113m In, in the upright and head-down posture, respectively, during tidal breathing. Both radiotracers remain fixed in the lung after administration. The distribution of radioactivity was mapped using quantitative single photon emission computed tomography (SPECT) corrected for attenuation and scatter. All images were obtained supine during tidal breathing. A shift from upright to the head-down posture caused a clear redistribution of blood flow from basal to apical regions. We conclude that posture plays a role for the distribution of lung blood flow in upright humans, and that the influence of posture, and thereby gravity, is much greater in the upright and head-down posture than in horizontal postures. However, the results of the study demonstrate that lung structure is the main determinant of regional blood flow and gravity is a secondary contributor to the distribution of lung blood flow in the upright and head-down positions. NEW & NOTEWORTHY Using a dual-isotope quantitative SPECT method, we demonstrated that although a shift in posture redistributes blood flow in the direction of gravity, the results are also consistent with lung structure being a greater determinant of regional blood flow than gravity. To our knowledge, this is the first study to use modern imaging methods to quantify the shift in regional lung blood flow in humans at a change between the upright and head-down postures. Copyright © 2017 the American Physiological Society.

  8. A Cross-sectional Morphometric Study of Thyroid Glands in Cadavers

    Directory of Open Access Journals (Sweden)

    Shrish Patil

    2017-10-01

    Full Text Available Introduction: Thyroid gland is an organ with a highly variable morphology. Despite several studies having been done to assess its measurements, a consensus has not been arrived at as to what constitutes a ‘normal’ thyroid. Aim: To determine the dimensions of the normal thyroid gland obtained from cadavers of South Indian region and to derive the mean and standard deviations of the measurements of the gland in the given population, thus contributing to the existing data. We also aimed to study three common but not constant components of the thyroid gland, namely Pyramidal Lobe (PL, Tubercle of Zukerkandl (TZ and Levator Glandulae Thyroideae (LGT. Materials and Methods: The study was conducted on thyroid glands obtained from cadavers of South Indian region. Institutional ethics committee approval was obtained. Sixty thyroid glands were obtained from cadavers received for either routine dissection or autopsies. The thyroid glands were studied after adequate exposure and fixing in formalin. Dimensions were measured using Vernier calipers. Specimens with anomalies like absent isthmus etc were excluded from the study. Statistical analysis was done using the MedCalc Version 17.0 software. Results: The average dimensions of the lobes were: height 3.83 cm, width 2.62 cm, and thickness 2.69 cm. The average dimensions of the isthmus were: height 1.38 cm, width 1.36 cm and thickness 1.29 cm. The average dimensions of the pyramidal lobe were: height 2.03 cm, width at the base 1.91 cm and thickness 1.16 cm. Pyramidal lobe was present in 60% of cases. Levator glandulae thyroideae was observable in three cases (5%. Significant correlation was found between the dimensions of right and left lobes and regression equations were calculated. Conclusion: The dimensions of the thyroid gland are very variable. Knowledge of the wide ranging variations and measurements will be of help to surgeons and radiologists in correct interpretation, diagnosis and treatment of

  9. Earliest directly-dated human skull-cups.

    Directory of Open Access Journals (Sweden)

    Silvia M Bello

    Full Text Available BACKGROUND: The use of human braincases as drinking cups and containers has extensive historic and ethnographic documentation, but archaeological examples are extremely rare. In the Upper Palaeolithic of western Europe, cut-marked and broken human bones are widespread in the Magdalenian (∼15 to 12,000 years BP and skull-cup preparation is an element of this tradition. PRINCIPAL FINDINGS: Here we describe the post-mortem processing of human heads at the Upper Palaeolithic site of Gough's Cave (Somerset, England and identify a range of modifications associated with the production of skull-cups. New analyses of human remains from Gough's Cave demonstrate the skilled post-mortem manipulation of human bodies. Results of the research suggest the processing of cadavers for the consumption of body tissues (bone marrow, accompanied by meticulous shaping of cranial vaults. The distribution of cut-marks and percussion features indicates that the skulls were scrupulously 'cleaned' of any soft tissues, and subsequently modified by controlled removal of the facial region and breakage of the cranial base along a sub-horizontal plane. The vaults were also 'retouched', possibly to make the broken edges more regular. This manipulation suggests the shaping of skulls to produce skull-cups. CONCLUSIONS: Three skull-cups have been identified amongst the human bones from Gough's Cave. New ultrafiltered radiocarbon determinations provide direct dates of about 14,700 cal BP, making these the oldest directly dated skull-cups and the only examples known from the British Isles.

  10. The accuracy of the lateral vertebral notch-referred pedicle screw insertion technique in subaxial cervical spine: a human cadaver study.

    Science.gov (United States)

    Luo, Jiaquan; Wu, Chunyang; Huang, Zhongren; Pan, Zhimin; Li, Zhiyun; Zhong, Junlong; Chen, Yiwei; Han, Zhimin; Cao, Kai

    2017-04-01

    This is a cadaver specimen study to confirm new pedicle screw (PS) entry point and trajectory for subaxial cervical PS insertion. To assess the accuracy of the lateral vertebral notch-referred PS insertion technique in subaxial cervical spine in cadaver cervical spine. Reported morphometric landmarks used to guide the surgeon in PS insertion show significant variability. In the previous study, we proposed a new technique (as called "notch-referred" technique) primarily based on coronal multiplane reconstruction images (CMRI) and cortical integrity after PS insertion in cadavers. However, the PS position in cadaveric cervical segment was not confirmed radiologically. Therefore, the difference between the pedicle trajectory and the PS trajectory using the notch-referred technique needs to be illuminated. Twelve cadaveric cervical spines were conducted with PS insertion using the lateral vertebral notch-referred technique. The guideline for entry point and trajectory for each vertebra was established based on the morphometric data from our previous study. After 3.5-mm diameter screw insertion, each vertebra was dissected and inspected for pedicle trajectory by CT scan. The pedicle trajectory and PS trajectory were measured and compared in axial plane. The perforation rate was assessed radiologically and was graded from ideal to unacceptable: Grade 0 = screw in pedicle; Grade I = perforation of pedicle wall less than one-fourth of the screw diameter; Grade II = perforation more than one-fourth of the screw diameter but less than one-second; Grade III = perforation more than one-second outside of the screw diameter. In addition, pedicle width between the acceptable and unacceptable screws was compared. A total of 120 pedicle screws were inserted. The perforation rate of pedicle screws was 78.3% in grade 0 (excellent PS position), 10.0% in grade I (good PS position), 8.3% in grade II (fair PS position), and 3.3% in grade III (poor PS position). The

  11. Differential protective effects of motorcycle helmets against head injury.

    Science.gov (United States)

    Singleton, Michael D

    2017-05-19

    Although numerous observational studies have demonstrated a protective effect of motorcycle helmets against head injury, the degree of protection against specific head injury types remains unclear. Experimental biomechanics studies involving cadavers, animals, and computer models have established that head injuries have varying etiologies. This retrospective cross-sectional study compared helmet protection against skull fracture, cerebral contusion, intracranial hemorrhage, and cerebral concussion in a consecutive series of motorcycle operators involved in recent traffic crashes in Kentucky. Police collision reports linked to hospital inpatient and emergency department (ED) claims were analyzed for the period 2008 to 2012. Motorcycle operators with known helmet use who were not killed at the crash scene were included in the study. Helmet use was ascertained from the police report. Skull fracture, cerebral contusion, intracranial hemorrhage, and cerebral concussion were identified from International Classification of Diseases, Ninth Revision, Clinical Modification (ICD-9-CM) codes on the claims records. The relative risks of each type of head injury for helmeted versus unprotected operators were estimated using generalized estimating equations. Helmets offer substantial protection against skull fracture (relative risk [RR] = 0.31, 95% confidence interval [CI], 0.23, 0.34), cerebral contusion (RR = 0.29, 95% CI, 0.16, 0.53), and intracranial hemorrhage (RR = 0.47, 95% CI, 0.35, 0.63). The findings pertaining to uncomplicated concussion (RR = 0.80, 95% CI, 0.64, 1.01) were inconclusive. A modest protective effect (20% risk reduction) was suggested by the relative risk estimate, but the 95% confidence interval included the null value. Motorcycle helmets were associated with a 69% reduction in skull fractures, 71% reduction in cerebral contusion, and 53% reduction in intracranial hemorrhage. This study finds that current motorcycle helmets do not protect equally against

  12. Channel heads in mountain catchments subject to human impact - The Skrzyczne range in Southern Poland

    Science.gov (United States)

    Wrońska-Wałach, Dominika; Żelazny, Mirosław; Małek, Stanisław; Krakowian, Katarzyna; Dąbek, Natalia

    2018-05-01

    Channel heads in mountain catchments are increasingly influenced by human activity. The disturbance of mountain headwater areas in moderate latitudes by the clearing of trees and the associated logging, road building and hydrotechnical constructions contribute to changes in the water cycle and consequently may induce a change in channel head development. Here we examine channel heads in the Beskid Śląski Mts., one of the areas most affected by ecological disaster in the Polish Flysch Carpathians. An ecological disaster associated with the decline of spruce trees in the 1980s and 1990s caused a substantial decrease (of about 50%) in the land area occupied by spruce forest in the Beskid Śląski Mts. As a result, headwater areas were subject to multidirectional changes in the environment. The purpose of this paper is to determine the detailed characteristics of channel heads currently developing in the analyzed headwater areas, as well as to identify independent factors that affect the evolution of channel heads. Geomorphological mapping was conducted in 2012 in the vicinity of springs in the study area. One-way ANOVA was used to determine the significance of differences between mean values calculated for groups identified based on: i) geomorphologic processes (hollows with rock veneer - h, spring niches - sn, gullies - g), ii) location vs. transformation of channel heads (forested areas vs., deforested areas with road constructions). Principal component analysis (PCA) was used to determine the structure and general patterns associated with relationships between the parameters of a channel head and its contribution area, as well as to identify and interpret new (orthogonal) spaces defined using distinct factors. As far as we know, this kind of approach has been never applied before. A total of 80 channel heads surrounding 104 springs were surveyed close to the main ridge in the study area. A total of 14 morphometric parameters were taken into account in this study

  13. EVALUATION OF EMF EXPOSURE OF MOBILE PHONES ON HUMAN HEAD

    Directory of Open Access Journals (Sweden)

    N. I. Vtornikova

    2017-01-01

    Full Text Available Introduction. Mobile phones are worldwide spread nowadays. Smartphones penetration is growing year after year. Numerous studies indicate the negative effect of EMF exposure of these devices on humans. Therefore, it is important to study the peculiarities of their influence on the target organ-the brain. It is important for solving this problem to find out the real situation of the distribution of energy flux density (EFD of EMF exposure near the front panel of the apparatus.The aim of the study is to determine and compare EMF exposure from smartphones and classic mobile phones on human head.Material and methods. The original method patented in the Russian Federation was used in this study. The used original measuring setup is also patented, developed and assembled by the authors of the study. The object of the study was classical mobile phones and smartphones widespread at the time of work.Results. We got the graphic of matrices of distribution of energy flux density (EFD of EMF exposure in the plane against the front panel of 10 apparatus corresponding to the topography of a human head. The study revealed peculiarities of this distribution in smartphones and the classic mobile phones and got the values of energy flux density (EFD of EMF exposure in the investigated devices acting primarily on the brain.Conclusions. The design of smartphones and mobile phones determines the overall picture of distribution of EFD of EMF exposure in the plane against the front panel for devices of a particular type. This picture must be taken into account when planning epidemiological and experimental studies to obtain comparable results. Progress in the development of mobile communication technologies has led to an increase in the electromagnetic load on users of modern devices.

  14. Multi-element determination in cancellous bone of human femoral head by PIXE

    International Nuclear Information System (INIS)

    Yuanxun Zhang; Yongping Zhang; Yongpeng Tong; Shijing Qiu; Xiaotao Wu; Kerong Dai

    1996-01-01

    Proton Induced X-ray Emission (PIXE) method is used for the determination of elemental concentrations in cancellous bone of human femoral head from five autopsies and seven patients with femoral neck broken. The specimen preparation and experimental procedure are described in detail. Using the t test, the results show that the concentrations of P, Ca, Fe, Cu, Sr in control group are higher than those in patient group, but the concentrations of S, K, Zn, Mn are not significantly different. The physiological functions of metallic elements in human bone are also discussed. (author). 19 refs., 1 fig., 4 tabs

  15. Human Papilloma Virus Associated Squamous Cell Carcinoma of the Head and Neck

    Science.gov (United States)

    Ajila, Vidya; Shetty, Harish; Babu, Subhas; Shetty, Veena; Hegde, Shruthi

    2015-01-01

    Oral cancer is one of the commonest causes for mortality and morbidity with squamous cell carcinoma being the sixth most frequent malignant tumour worldwide. In addition to tobacco and alcohol, human papilloma virus (HPV) is associated with a proportion of head and neck cancers. As in cervical cancers, HPV types 16 and 18 are the cause of malignant transformation. HPV-positive cancers of head and neck have unique characteristics such as occurrence in a younger age group, distinct clinical and molecular features, and better prognosis as compared to HPV-negative carcinomas. They also possess the potential for prevention by using vaccination. The present review describes in detail the salient features of HPV associated oral squamous cell carcinoma (OSCC), its differences from HPV-negative OSCC, diagnostic features, and recent strategies in prevention and management. PMID:26483987

  16. Human Papilloma Virus Associated Squamous Cell Carcinoma of the Head and Neck.

    Science.gov (United States)

    Ajila, Vidya; Shetty, Harish; Babu, Subhas; Shetty, Veena; Hegde, Shruthi

    2015-01-01

    Oral cancer is one of the commonest causes for mortality and morbidity with squamous cell carcinoma being the sixth most frequent malignant tumour worldwide. In addition to tobacco and alcohol, human papilloma virus (HPV) is associated with a proportion of head and neck cancers. As in cervical cancers, HPV types 16 and 18 are the cause of malignant transformation. HPV-positive cancers of head and neck have unique characteristics such as occurrence in a younger age group, distinct clinical and molecular features, and better prognosis as compared to HPV-negative carcinomas. They also possess the potential for prevention by using vaccination. The present review describes in detail the salient features of HPV associated oral squamous cell carcinoma (OSCC), its differences from HPV-negative OSCC, diagnostic features, and recent strategies in prevention and management.

  17. Biomechanical analysis of range of motion and failure characteristics of osteoporotic spinal compression fractures in human cadaver

    Directory of Open Access Journals (Sweden)

    Robert F Heary

    2017-01-01

    Full Text Available Background: Vertebroplasty is a treatment for osteoporotic vertebral compression fractures. The optimal location of needle placement for cement injection remains a topic of debate. As such, the authors assessed the effects of location of two types of cement instillations. In addition, the motion and failure modes at the index and adjacent segments were measured. Materials and Methods: Seven human osteoporotic cadaver spines (T1-L4, cut into four consecutive vertebral segments, were utilized. Of these, following the exclusion of four specimens not suitable to utilize for analysis, a total of 24 specimens were evaluable. Segments were randomly assigned into four treatment groups: unipedicular and bipedicular injections into the superior quartile or the anatomic center of the vertebra using confidence (Confidence Spinal Cement System®, DePuy Spine, Raynham, MA, USA or polymethyl methacrylate. The specimens were subjected to nondestructive pure moments of 5 Nm, in 2.5 Nm increments, using pulleys and weights to simulate six degrees of physiological motion. A follower preload of 200 N was applied in flexion extension. Testing sequence: range of motion (ROM of intact specimen, fracture creation, cement injection, ROM after cement, and compression testing until failure. Nonconstrained motion was measured at the index and adjacent levels. Results: At the index level, no significant differences were observed in ROM in all treatment groups (P > 0.05. There was a significant increase in adjacent level motion only for the treatment group that received a unipedicular cement injection at the anatomic center. Conclusion: The location of the needle (superior or central and treatment type (unipedicular or bipedicular had no significant effect on the ROM at the index site. At the adjacent levels, a significant increase occurred with therapy through a unipedicular approach into the centrum of the vertebra at the treated segment.

  18. Progression of thanatophagy in cadaver brain and heart tissues

    Directory of Open Access Journals (Sweden)

    Gulnaz T. Javan

    2016-03-01

    Full Text Available Autophagy is an evolutionarily conserved catabolic process for maintaining cellular homeostasis during both normal and stress conditions. Metabolic reprogramming in tissues of dead bodies is inevitable due to chronic ischemia and nutrient deprivation, which are well-known features that stimulate autophagy. Currently, it is not fully elucidated whether postmortem autophagy, also known as thanatophagy, occurs in dead bodies is a function of the time of death. In this study, we tested the hypothesis that thanatophagy would increase in proportion to time elapsed since death for tissues collected from cadavers. Brain and heart tissue from corpses at different time intervals after death were analyzed by Western blot. Densitometry analysis demonstrated that thanatophagy occurred in a manner that was dependent on the time of death. The autophagy-associated proteins, LC3 II, p62, Beclin-1 and Atg7, increased in a time-dependent manner in heart tissues. A potent inducer of autophagy, BNIP3, decreased in the heart tissues as time of death increased, whereas the protein levels increased in brain tissues. However, there was no expression of BNIP3 at extended postmortem intervals in both brain and heart samples. Collectively, the present study demonstrates for the first time that thanatophagy occurs in brain and heart tissues of cadavers in a time-dependent manner. Further, our data suggest that cerebral thanatophagy may occur in a Beclin-1- independent manner. This unprecedented study provides potential insight into thanatophagy as a novel method for the estimation of the time of death in criminal investigationsAbstract: Autophagy is an evolutionarily conserved catabolic process for maintaining cellular homeostasis during both normal and stress conditions. Metabolic reprogramming in tissues of dead bodies is inevitable due to chronic ischemia and nutrient deprivation, which are well-known features that stimulate autophagy. Currently, it is not fully

  19. Electroosmotic pore transport in human skin.

    Science.gov (United States)

    Uitto, Olivia D; White, Henry S

    2003-04-01

    To determine the pathways and origin of electroosmotic flow in human skin. Iontophoretic transport of acetaminophen in full thickness human cadaver skin was visualized and quantified by scanning electrochemical microscopy. Electroosmotic flow in the shunt pathways of full thickness skin was compared to flow in the pores of excised stratum corneum and a synthetic membrane pore. The penetration of rhodamine 6G into pore structures was investigated by laser scanning confocal microscopy. Electroosmotic transport is observed in shunt pathways in full thickness human skin (e.g., hair follicles and sweat glands), but not in pore openings of freestanding stratum corneum. Absolute values of the diffusive and iontophoretic pore fluxes of acetaminophen in full thickness human skin are also reported. Rhodamine 6G is observed to penetrate to significant depths (approximately 200 microm) along pore pathways. Iontophoresis in human cadaver skin induces localized electroosmotic flow along pore shunt paths. Electroosmotic forces arise from the passage of current through negatively charged mesoor nanoscale pores (e.g., gap functions) within cellular regions that define the pore structure beneath the stratum corneum.

  20. Exploratory study on the methodology of fast imaging of unilateral stroke lesions by electrical impedance asymmetry in human heads.

    Science.gov (United States)

    Ma, Jieshi; Xu, Canhua; Dai, Meng; You, Fusheng; Shi, Xuetao; Dong, Xiuzhen; Fu, Feng

    2014-01-01

    Stroke has a high mortality and disability rate and should be rapidly diagnosed to improve prognosis. Diagnosing stroke is not a problem for hospitals with CT, MRI, and other imaging devices but is difficult for community hospitals without these devices. Based on the mechanism that the electrical impedance of the two hemispheres of a normal human head is basically symmetrical and a stroke can alter this symmetry, a fast electrical impedance imaging method called symmetrical electrical impedance tomography (SEIT) is proposed. In this technique, electrical impedance tomography (EIT) data measured from the undamaged craniocerebral hemisphere (CCH) is regarded as reference data for the remaining EIT data measured from the other CCH for difference imaging to identify the differences in resistivity distribution between the two CCHs. The results of SEIT imaging based on simulation data from the 2D human head finite element model and that from the physical phantom of human head verified this method in detection of unilateral stroke.

  1. Primary fit of the Lord cementless total hip : a geometric study in cadavers

    NARCIS (Netherlands)

    Schimmel, J.W.; Huiskes, H.W.J.

    1988-01-01

    Two Lord prostheses, bilaterally implanted in cadavers, were sectioned. The contact areas between bone and prosthesis were studied and measured using a specially developed reproducible method. Primary fixation of the femoral components appeared to be based principally on wedging of the prosthetic

  2. BrainK for Structural Image Processing: Creating Electrical Models of the Human Head

    Directory of Open Access Journals (Sweden)

    Kai Li

    2016-01-01

    Full Text Available BrainK is a set of automated procedures for characterizing the tissues of the human head from MRI, CT, and photogrammetry images. The tissue segmentation and cortical surface extraction support the primary goal of modeling the propagation of electrical currents through head tissues with a finite difference model (FDM or finite element model (FEM created from the BrainK geometries. The electrical head model is necessary for accurate source localization of dense array electroencephalographic (dEEG measures from head surface electrodes. It is also necessary for accurate targeting of cerebral structures with transcranial current injection from those surface electrodes. BrainK must achieve five major tasks: image segmentation, registration of the MRI, CT, and sensor photogrammetry images, cortical surface reconstruction, dipole tessellation of the cortical surface, and Talairach transformation. We describe the approach to each task, and we compare the accuracies for the key tasks of tissue segmentation and cortical surface extraction in relation to existing research tools (FreeSurfer, FSL, SPM, and BrainVisa. BrainK achieves good accuracy with minimal or no user intervention, it deals well with poor quality MR images and tissue abnormalities, and it provides improved computational efficiency over existing research packages.

  3. The relationship between cadaver, living and forensic stature: A review of current knowledge and a test using a sample of adult Portuguese males.

    Science.gov (United States)

    Cardoso, Hugo F V; Marinho, Luísa; Albanese, John

    2016-01-01

    The use of cadaver length and forensic stature as a proxy for living standing height has not been scrutinized in detail. In this paper we present a brief review of the current knowledge on the relationship between cadaver, living and forensic stature; assess the magnitude and nature of the differences between these three measures of stature; and investigate the potential impact of these differences in forensic contexts. The study uses a sample of 84 males who were autopsied in 2008 at the National Institute of Legal Medicine and Forensic Sciences (Porto, Portugal), where stature data were collected from three different sources: cadaver stature was obtained from the corpse prior to autopsy, living stature was obtained from military conscription records and forensic stature was obtained from national citizenship identification card records. Descriptive statistics, ANOVA and linear regression are used to analyze the data. The results show that cadaver stature is the highest measure, followed by forensic and by living stature, and the difference between cadaver and living stature is greater than expected (4.3cm). Results also show considerable individual variation in the differences between the three measures of stature and that differences decrease with stature, although only slightly. This study has shown that the difference between cadaver and living stature is greater than previously thought and suggests that previously reported correction factors are a minimum rather than a mean correction. Forensic stature is likely to be incorrectly estimated and can jeopardize identification if methods estimate living rather than forensic stature. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Penetrating and Intrastromal Corneal Arcuate Incisions in Rabbit and Human Cadaver Eyes: Manual Diamond Blade and Femtosecond Laser-Created Incisions.

    Science.gov (United States)

    Gray, Brad; Binder, Perry S; Huang, Ling C; Hill, Jim; Salvador-Silva, Mercedes; Gwon, Arlene

    2016-07-01

    To compare morphologic differences between freehand diamond or femtosecond laser-assisted penetrating and intrastromal arcuate incisions. Freehand diamond blade, corneal arcuate incisions (180° apart, 60° arc lengths) and 150 kHz femtosecond laser (80% scheimpflug pachymetry depth corneal thickness) arcuate incisions were performed in rabbits. Intrastromal arcuate incisions (100 μm above Descemet's membrane, 100 μm below epithelium) were performed in rabbit corneas (energy 1.2 μJ, spot line separation 3 × 3 μm, 90° side cut angle). Eyes were examined by slit lamp and light microscopy up to 47 days post-procedure. Freehand diamond blade penetrating incisions, and femtosecond laser penetrating and intrastromal arcuate incisions (energy 1.8 μJ, spot line separation 2 × 2 μm) were performed in cadaver eyes. Optical coherence tomography was performed immediately after surgery and the corneas were fixed for light scanning and transmission electron microscopy. The rabbit model showed anterior stromal inflammation with epithelial hyperplasia in penetrating blade and laser penetrating wounds. The laser intrastromal and penetrating incisions showed localized constriction of the stromal layers of the cornea near the wound. In cadaver eyes, penetrating wound morphology was similar between blade and laser whereas intrastromal wounds did not affect the cornea above or below incisions. Penetrating femtosecond laser arcuate incisions have more predictable and controlled outcomes shown by less post-operative scarring than incisions performed with a diamond blade. Intrastromal incisions do not affect uncut corneal layers as demonstrated by histopathology. The femtosecond laser has significant advantages in its ability to make intrastromal incisions which are not achievable by traditional freehand or mechanical diamond blades.

  5. 45 CFR 1308.21 - Parent participation and transition of children into Head Start and from Head Start to public...

    Science.gov (United States)

    2010-10-01

    ... into Head Start and from Head Start to public school. 1308.21 Section 1308.21 Public Welfare... AND HUMAN SERVICES THE ADMINISTRATION FOR CHILDREN, YOUTH AND FAMILIES, HEAD START PROGRAM HEAD START... Standards § 1308.21 Parent participation and transition of children into Head Start and from Head Start to...

  6. Efficacy of orthotic immobilization of the unstable subaxial cervical spine of the elderly patient: investigation in a cadaver model

    Science.gov (United States)

    Bednar, Drew A.

    2004-01-01

    Objective To assess the efficacy of soft, semirigid and hard cervical collars to immobilize the neck in a destabilized cadaver model. Design This is a laboratory experiment. Setting The anatomy research lab of McMaster University. Patients None. Fresh cadavers from elderly patients suffering terminal medical illness and free of cervical structural disease were studied. Interventions Destabilizing discoligamentous lesions of the neck were created in the cadavers. Radiographs were taken in maximum displacement in the prone, decubitus and side-bending positions, first unsupported and then with soft, semirigid and hard collars applied. Displacements in angulation and translation were measured from the radiographs. Outcome measures Radiographic displacement under gravity load. Results In all cases there was no effective limitation of pathological displacement, and in many cases displacement was increased after collar application. Conclusions Cervical collars do not effectively support the unstable neck, and may be ineffective in preventing pathological displacements. PMID:15362326

  7. Tribological changes in the articular cartilage of a human femoral head with avascular necrosis.

    Science.gov (United States)

    Seo, Eun-Min; Shrestha, Suman K; Duong, Cong-Truyen; Sharma, Ashish Ranjan; Kim, Tae-Woo; Vijayachandra, Ayyappan; Thompson, Mark S; Cho, Myung Guk; Park, Sungchan; Kim, Kwanghoon; Park, Seonghun; Lee, Sang-Soo

    2015-06-29

    The present study evaluated the tribological properties of the articular cartilage surface of the human femoral head with postcollapse stage avascular necrosis (AVN) using atomic force microscopy. The cartilage surface in the postcollapse stage AVN of the femoral head was reported to resemble those of disuse conditions, which suggests that the damage could be reversible and offers the possibilities of success of head-sparing surgeries. By comparing the tribological properties of articular cartilage in AVN with that of osteoarthritis, the authors intended to understand the cartilage degeneration mechanism and reversibility of AVN. Human femoral heads with AVN were explanted from the hip replacement surgery of four patients (60-83 years old). Nine cylindrical cartilage samples (diameter, 5 mm and height, 0.5 mm) were sectioned from the weight-bearing areas of the femoral head with AVN, and the cartilage surface was classified according to the Outerbridge Classification System (AVN0, normal; AVN1, softening and swelling; and AVN2, partial thickness defect and fissuring). Tribological properties including surface roughness and frictional coefficients and histochemistry including Safranin O and lubricin staining were compared among the three groups. The mean surface roughness Rq values of AVN cartilage increased significantly with increasing Outerbridge stages: Rq = 137 ± 26 nm in AVN0, Rq = 274 ± 49 nm in AVN1, and Rq = 452 ± 77 nm in AVN2. Significant differences in Rq were observed among different Outerbridge stages in all cases (p AVN0, μ = 0.143 ± 0.025 in AVN1, and μ = 0.171 ± 0.039 in AVN2. Similarly to the statistical analysis of surface roughness, significant statistical differences were detected between different Outerbridge stages in all cases (p AVN. The underlying mechanism of these results can be related to proteoglycan loss within the articular cartilage that is also observed in osteoarthritis. With regard to the tribological properties, the

  8. Proteomics Analyses of Human Optic Nerve Head Astrocytes Following Biomechanical Strain*

    OpenAIRE

    Rogers, Ronan S.; Dharsee, Moyez; Ackloo, Suzanne; Sivak, Jeremy M.; Flanagan, John G.

    2011-01-01

    We investigate the role of glial cell activation in the human optic nerve caused by raised intraocular pressure, and their potential role in the development of glaucomatous optic neuropathy. To do this we present a proteomics study of the response of cultured, optic nerve head astrocytes to biomechanical strain, the magnitude and mode of strain based on previously published quantitative models. In this case, astrocytes were subjected to 3 and 12% stretches for either 2 h or 24 h. Proteomic me...

  9. Feasibility of using interstitial ultrasound for intradiscal thermal therapy: a study in human cadaver lumbar discs

    International Nuclear Information System (INIS)

    Nau, William H; Diederich, Chris J; Shu, Richard

    2005-01-01

    Application of heat in the spine using resistive wire heating devices is currently being used clinically for minimally invasive treatment of discogenic low back pain. In this study, interstitial ultrasound was evaluated for the potential to heat intradiscal tissue more precisely by directing energy towards the posterior annular wall while avoiding vertebral bodies. Two single-element directional applicator design configurations were tested: a 1.5 mm OD direct-coupled (DC) applicator which can be implanted directly within the disc, and a catheter-cooled (CC) applicator which is inserted in a 2.4 mm OD catheter with integrated water cooling and implanted within the disc. The transducers were sectored to produce 90 deg. spatial heating patterns for directional control. Both applicator configurations were evaluated in four human cadaver lumbar disc motion segments. Two heating protocols were employed in this study in which the temperature measured 5 mm away from the applicator was controlled to either T = 52 deg. C, or T > 70 deg. C for the treatment period. These temperatures (thermal doses) are representative of those required for thermal necrosis of in-growing nociceptor nerve fibres and disc cellularity alone, or with coagulation and restructuring of annular collagen in the high-temperature case. Steady-state temperature maps, and thermal doses (t 43 ) were used to assess the thermal treatments. Results from these studies demonstrated the capability of controlling temperature distributions within selected regions of the disc and annular wall using interstitial ultrasound, with minimal vertebral end-plate heating. While directional heating was demonstrated with both applicator designs, the CC configuration had greater directional heating capabilities and offered better temperature control than the DC configuration, particularly during the high-temperature protocol. Further, ultrasound energy was capable of penetrating within the highly attenuating disc tissue to

  10. Insects (Diptera) associated with cadavers at the Institute of Legal Medicine in Pernambuco, Brazil: implications for forensic entomology.

    Science.gov (United States)

    Oliveira, Tatiana Costa; Vasconcelos, Simao Dias

    2010-05-20

    Increasing rates of unsolved homicides in Brazil prompt the need for applied entomological data to be used as a complementary tool by criminal investigators. In that context, we analyzed the occurrence of forensically important insect species (Order Diptera) on 14 cadavers taken into the Institute of Legal Medicine (ILM), in Pernambuco, Brazil, according to the conditions of the body and the pattern of colonisation by insects. Simultaneously, we surveyed the diversity of insects in the surrounding environment using bait traps. Five species were present on cadavers: Chrysomya albiceps, Chrysomya megacephala and Cochliomyia macellaria (Calliphoridae), Oxysarcodexia riograndensis and Ravinia belforti (Sarcophagidae). A total of 4689 adult insects belonging to 24 species of seven dipteran families (Calliphoridae, Sarcophagidae, Muscidae, Fanniidae, Phoridae, Anthomyiidae and Stratiomyidae) was collected at the ILM premises. C. albiceps was the most frequent species on the corpses and the most abundant in the traps. Species referred to as of forensic importance, such as Lucilia eximia, Chrysomya putoria, Oxysarcodexia modesta and Ophyra chalcogaster were collected on traps, but not on cadavers. There seems to be a limited colonisation of cadavers at the scene of the death, despite the ubiquity of necrophagous species in the area. The results contribute to differentiate between species that are involved in decomposition and those found in and around the mortuary installations of the ILM, thus providing potential clues about the locality of death and the post-mortem interval.

  11. Anatomic variations found on dissection of depressor septi nasi muscles in cadavers.

    Science.gov (United States)

    Ebrahimi, Ali; Nejadsarvari, Nasrin; Motamedi, Mohammad Hosein Kalantar; Rezaee, Maryam; Koushki, Ehsan Shams

    2012-01-01

    To define variations of the depressor septi muscle in Iranians; to provide guidance for modification of this muscle during rhinoplasty in patients with an active muscle and short upper lip; and to correlate our findings with our clinical experience to develop the applied algorithms. This study was conducted by dissecting 82 depressor septi nasi muscles in 41 Iranian cadavers. Origin and insertion points of each muscle were studied. Three variations were found in muscle insertion points: periosteal, orbicularis oris, and floating. Forty-four percent of the muscles were inserted into the periosteum of the maxilla (n = 36); 39% of muscles were inserted into the orbicularis oris muscle (n = 32); and 17% were diminutive or floating (n = 14). Periosteal insertion was thicker and stronger than the other variations. In all cadavers, the origin of the muscle was medial crus of alar cartilage and caudal of the nasal septum. This cadaveric dissection showed that the percentage of depressor septi muscle insertions is not similar to that found in other surveys. In this study, periosteal insertion of the depressor septi muscle was the most common variation.

  12. Simulation training using cadaver sheep chest in pleuroscopy - A step towards skills enhancement

    International Nuclear Information System (INIS)

    Mahmud, T.; Saqib, M.; Nasir, T.; Siddique, N.

    2017-01-01

    Objectives: For assessing the use of if simulation training on animal cadavers as a useful tool for training in pleuroscopy. Methods: The email-based cross-sectional study was conducted in December 2014 at Shaikh Zayed Hospital, Federal Postgraduate Medical Institute, Lahore, Pakistan, and comprised respiratory physicians and trainees after their participation in a two-day hands-on training course on pleuroscopy and pleural medical procedures. The responses were analysed and the responses of physicians and trainees were compared. Results: Of the 44 individuals who attended the course and were contacted through emails, 38(86.4%) responded, including 20(52.6%) physicians and 18(47.3%) trainees. All the 38(100%) subjects uniformly accepted the utility of simulation training in enhancing education, improving skill, and improving confidence by repeated practice, and felt that the inclusion of animal models for learning fundamental pleuroscopic procedures can help a lot in teaching. Conclusion: Animal cadavers can be used as an effective teaching tool for pleuroscopy training. (author)

  13. Feasibility and Benefit of Incorporating a Multimedia Cadaver Laboratory Training Program into a Didactics Curriculum for Junior and Senior Surgical Residents.

    Science.gov (United States)

    Simmerman, Erika; Simmerman, Andrew; Lassiter, Randi; King, Ray; Ham, Ben; Adam, Bao-Ling; Ferdinand, Colville; Holsten, Steven

    2018-04-17

    As operative experience in general surgery decreases and work hour limitations increase there is less exposure of surgical residents to advanced vascular and trauma exposures. Many institutions have demonstrated benefits of cadaver laboratory courses. We have incorporated a multimedia cadaver laboratory course into our general surgery residency didactics curriculum with the objective to demonstrate a benefit of the program as well as the feasibility of incorporation. This is a prospective study at a tertiary care institution including general surgery residents within our residency program. A curriculum was designed, requiring residents to complete multimedia learning modules before both a trauma cadaver laboratory and vascular exposure cadaver laboratory. Outcome measures included self-efficacy/confidence (precourse and postcourse 5-point Likert surveys), knowledge (net performance on precourse and postcourse multiple choice examinations), and resident perception of the curriculum (postcourse 5-point Likert survey). Data were analyzed using ANOVA paired t-tests. For the vascular cadaver laboratory, resident knowledge improved overall from an average of 41.2% to 50.0% of questions correct (p = 0.032) and self-efficacy/confidence improved by 0.59 from 1.52 to 2.11 out of 5 (p = 0.009). Median confidence is 1.37 out of 5 and 2.32 out of 5, before and after course, respectively. Wilcoxon nonparametric test reveals a p = 0.011. Resident's perception of the usefulness of the laboratory evaluation was 3.85 out 5. There were 85.71% agreed that the laboratory is useful and 14.29% were disagree. The Z-score is -0.1579 (means 0.1579 standard deviations a score of 3.85 below the benchmark). The percentile rank is 56.27%. The coefficient of variation is 24.68%. For the trauma cadaver laboratory, resident knowledge improved overall from an average of 55.89% to 66.17% of questions correct (p = 0.001) and self-efficacy/confidence improved by 0.75 from 1.68 out of 5 to 2.43 out of

  14. Three-dimensional computed tomographic evaluation of bilateral sagittal split osteotomy lingual fracture line and le fort I pterygomaxillary separation in orthognathic surgery using cadaver heads: ultrasonic osteotome versus conventional saw.

    Science.gov (United States)

    Dammous, Sophie; Dupont, Quentin; Gilles, Roland

    2015-06-01

    The purpose of this study was to observe the quality of the fracture line on the lingual side of the mandible after sagittal split osteotomy and the quality of pterygomaxillary separation after Le Fort I osteotomy using the BoneScalpel ultrasonic osteotome. Bimaxillary procedures, according to the standard protocol, were performed using 10 fresh cadaver heads. The ultrasonic osteotome was used in the study group, and a reciprocating saw was used in the control group. Three-dimensional reconstructions of postoperative computed tomographic scans were obtained. The lingual ramus fracture pattern and the pterygomaxillary separation pattern were observed, classified, and compared. Postoperative dissections of the skulls were performed to assess the integrity of the infra-alveolar nerve and the descending palatine artery. No significant differences were found in the cutting time of bone between the BoneScalpel and the sagittal saw. Of the sagittal split osteotomies in the study group, 90% showed a good pattern (vertical pattern of fracture line extending to the inferior border of the mandible running behind the mandibular canal) compared with 50% of the sagittal split osteotomies in the control group. Ideal separation of the pterygoid plates without fractures was observed in 80% of the Le Fort I osteotomies in the study group compared with 50% of the osteotomies in the control group. High-level fractures occurred in 30% of cases in the control group compared with none in the study group. The integrities of the infra-alveolar nerve and the descending palatine artery were preserved in all cases. Use of the ultrasonic BoneScalpel did not require more time than the conventional method. An improved pattern of lingual fracture lines in mandibular sagittal split osteotomy procedures and the pattern of pterygomaxillary separation in Le Fort I osteotomy procedures were observed. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc

  15. The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ganguly, Rumpa; Ramesh, Aruna; Pagni, Sarah [Tufts University School of Dental Medicine, Boston (United States)

    2016-06-15

    The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view (13 cm×16 cm) and small field of view (5 cm×8 cm) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

  16. Density distribution of currents induced inside the brain in the head part of the human model exposed to power frequency electric field

    Energy Technology Data Exchange (ETDEWEB)

    Chiba, Atsuo [Yongo National Collage of Technology (Japan); Isaka, Katsuo [University of Tokushima (Japan)

    1999-07-01

    The health effect of the weak current induced in the human body as a result of the interaction between human body and power frequency electric fields has been investigated. However, the current density inside the head part tissues of the human body exposed to the electric fields has rarely been discussed. In this paper, the finite element method is applied to the analysis of the current density distribution of the head part composed of scalp, skull, cerebrospinal liquid and brain tissues. The basic characteristics of the current density distributions of the brain in the asymmetrical human model have been made clear. (author)

  17. Crash-Resistant Crewseat Limit-Load Optimization through Dynamic Testing with Cadavers

    Science.gov (United States)

    1986-01-01

    shell on each surface of the verte- bral centrum is referred to as the bony end plate. Facing this bony end plate is a thin layer of hyaline cartilage ...most realistically, two vertebrae with the included intervertebral disc and hyaline cartilage . This section is referred to as the intervertebral joint...strengths of vertebrae from various studies ......... ... .......................... 5 2 Sumary of the test matrix for the cadaver test program . 33 3 Test

  18. 'Goats that stare at men'--revisited: do dwarf goats alter their behaviour in response to eye visibility and head direction of a human?

    Science.gov (United States)

    Nawroth, Christian; von Borell, Eberhard; Langbein, Jan

    2016-05-01

    Being able to recognise when one is being observed by someone else is thought to be adaptive during cooperative or competitive events. In particular for prey species, this ability should be of use in the context of predation. A previous study reported that goats (Capra aegagrus hircus) alter their behaviour according to the body and head orientation of a human experimenter. During a food anticipation task, an experimenter remained in a particular posture for 30 s before delivering a reward, and the goats' active anticipation and standing alert behaviour were analysed. To further evaluate the specific mechanisms at work, we here present two additional test conditions. In particular, we investigated the effects of the eye visibility and head orientation of a human experimenter on the behaviour of the goats (N = 7). We found that the level of the subjects' active anticipatory behaviour was highest in the conditions where the experimenter was directing his head and body towards the goat ('Control' and 'Eyes closed' conditions), but the anticipatory behaviour was significantly decreased when the body ('Head only') or the head and body of the experimenter were directed away from the subject ('Back' condition). For standing alert, we found no significant differences between the three conditions in which the experimenter was directing his head towards the subject ('Control', 'Eyes closed' and 'Head only'). This lack of differences in the expression of standing alert suggests that goats evaluate the direction of a human's head as an important cue in their anticipatory behaviour. However, goats did not respond to the visibility of the experimenter's eyes alone.

  19. Advanced surgical skills for exposure in trauma: a new surgical skills cadaver course for surgery residents and fellows.

    Science.gov (United States)

    Kuhls, Deborah A; Risucci, Donald A; Bowyer, Mark W; Luchette, Fred A

    2013-02-01

    Surgical education is changing owing to workforce and economic demands. Simulation and other technical teaching methods are used to acquire skills transferable to the operating room. Operative management of traumatic injuries has declined, making it difficult to acquire and maintain competence. The ASSET course was developed by the Committee on Trauma's Surgical Skills Committee to fill a surgical skills need in resident and fellow education. Using a human cadaver, standardized rapid exposure of vital structures in the extremities, neck, thorax, abdomen, retroperitoneum, and pelvis is taught. A retrospective analysis of 79 participants in four ASSET courses was performed. Operative experience data were collected, and self-efficacy questionnaires (SEQs) were administered before and after the course. Course evaluations and instructor evaluation data were analyzed. Student's and paired samples t tests as well as analysis of variance and Spearman ρ correlation coefficient analysis were performed using α at p ASSET course would teach new surgical techniques and that learner self-assessed ability would improve. Participants included 27 PGY-4, 20 PGY-5, 24 PGY-6 or PGY-7 and PGY-8 at other levels of training. Self-assessed confidence improved in all body regions (p knowledge rated at 4.8 and learning new techniques at 4.72. A standardized cadaver-based surgical exposures course offered to senior surgical residents adds new surgical skills and improves participant self-assessed ability to perform emergent surgical exposure of vital structures.

  20. Transvaginal Pelvic Floor Muscle Injection Technique: A Cadaver Study.

    Science.gov (United States)

    Gupta, Priyanka; Ehlert, Michael; Sirls, Larry T; Peters, Kenneth

    Women with pelvic floor dysfunction can have tender areas on vaginal examination, which can be treated with trigger-point injections. There are no publications to evaluate the accuracy of pelvic floor muscle injections. Trigger-point injections were performed on 2 fresh cadaveric pelvises using a curved nasal cannula guide and 7-in spinal needle. This was performed using our standard template of 2 sets of injections at the 1-, 3-, and 5-o'clock positions distally and proximally. The first pelvis was dissected to examine dye penetration. Based on these results, we modified our technique and repeated the injections on the second cadaver. We dissected the second pelvis and compared our findings. The 1-o'clock proximal and distal injections stained the obturator internus and externus near the insertion at the ischiopubic ramus. The 3-o'clock injections stained the midbody of the pubococcygeus and puborectalis. The distal 5-o'clock position was too deep and stained the fat of the ischiorectal space. The proximal 5-o'clock injection stained the area of the pudendal nerve. Our goal at the distal 5-o'clock position was to infuse the iliococcygeus muscle, so we shortened the needle depth from 2 to 1 cm beyond the cannula tip. In our second dissection, the distal 5-o'clock injection again stained only the fat of the ischiorectal space. This is the first study to characterize the distribution of pelvic floor muscle injections in a cadaver model and confirms the ability to deliver medications effectively to the pelvic floor muscles.

  1. Initial insights into bacterial succession during human decomposition.

    Science.gov (United States)

    Hyde, Embriette R; Haarmann, Daniel P; Petrosino, Joseph F; Lynne, Aaron M; Bucheli, Sibyl R

    2015-05-01

    Decomposition is a dynamic ecological process dependent upon many factors such as environment, climate, and bacterial, insect, and vertebrate activity in addition to intrinsic properties inherent to individual cadavers. Although largely attributed to microbial metabolism, very little is known about the bacterial basis of human decomposition. To assess the change in bacterial community structure through time, bacterial samples were collected from several sites across two cadavers placed outdoors to decompose and analyzed through 454 pyrosequencing and analysis of variable regions 3-5 of the bacterial 16S ribosomal RNA (16S rRNA) gene. Each cadaver was characterized by a change in bacterial community structure for all sites sampled as time, and decomposition, progressed. Bacteria community structure is variable at placement and before purge for all body sites. At bloat and purge and until tissues began to dehydrate or were removed, bacteria associated with flies, such as Ignatzschineria and Wohlfahrtimonas, were common. After dehydration and skeletonization, bacteria associated with soil, such as Acinetobacter, were common at most body sites sampled. However, more cadavers sampled through multiple seasons are necessary to assess major trends in bacterial succession.

  2. The Histopathologic Reliability of Tissue Taken from Cadavers within the Gross Anatomy Laboratory

    Science.gov (United States)

    Rae, Guenevere; Newman, William P., III; McGoey, Robin; Donthamsetty, Supriya; Karpinski, Aryn C.; Green, Jeffrey

    2018-01-01

    The purpose of this study was to examine the histopathologic reliability of embalmed cadaveric tissue taken from the gross anatomy laboratory. Tissue samples from hearts, livers, lungs, and kidneys were collected after the medical students' dissection course was completed. All of the cadavers were embalmed in a formalin-based fixative solution.…

  3. A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures.

    Science.gov (United States)

    Jenkins, Paul J; Ramaesh, Rishikesan; Pankaj, Pankaj; Patton, James T; Howie, Colin R; Goffin, Jérôme M; Merwe, Andrew van der; Wallace, Robert J; Porter, Daniel E; Simpson, A Hamish

    2013-10-01

    The micro-architecture of bone has been increasingly recognized as an important determinant of bone strength. Successful operative stabilization of fractures depends on bone strength. We evaluated the osseous micro-architecture and strength of the osteoporotic human femoral head. 6 femoral heads, obtained during arthroplasty surgery for femoral neck fracture, underwent micro-computed tomography (microCT) scanning at 30 μm, and bone volume ratio (BV/TV), trabecular thickness, structural model index, connection density, and degree of anisotropy for volumes of interest throughout the head were derived. A further 15 femoral heads underwent mechanical testing of compressive failure stress of cubes of trabecular bone from different regions of the head. The greatest density and trabecular thickness was found in the central core that extended from the medial calcar to the physeal scar. This region also correlated with the greatest degree of anisotropy and proportion of plate-like trabeculae. In the epiphyseal region, the trabeculae were organized radially from the physeal scar. The weakest area was found at the apex and peripheral areas of the head. The strongest region was at the center of the head. The center of the femoral head contained the strongest trabecular bone, with the thickest, most dense trabeculae. The apical region was weaker. From an anatomical and mechanical point of view, implants that achieve fixation in or below this central core may achieve the most stable fixation during fracture healing.

  4. Influence of stiffness and shape of contact surface on skull fractures and biomechanical metrics of the human head of different population underlateral impacts.

    Science.gov (United States)

    Shaoo, Debasis; Deck, Caroline; Yoganandan, Narayan; Willinger, Rémy

    2015-07-01

    The objective of this study was to determine the responses of 5th-percentile female, and 50th- and 95th-percentile male human heads during lateral impacts at different velocities and determine the role of the stiffness and shape of the impacting surface on peak forces and derived skull fracture metrics. A state-of-the-art validated finite element (FE) head model was used to study the influence of different population human heads on skull fracture for lateral impacts. The mass of the FE head model was altered to match the adult size dummies. Numerical simulations of lateral head impacts for 45 cases (15 experiments×3 different population human heads) were performed at velocities ranging from 2.4 to 6.5m/s and three impacting conditions (flat and cylindrical 90D; and flat 40D padding). The entire force-time signals from simulations were compared with experimental mean and upper/lower corridors at each velocity, stiffness (40 and 90 durometer) and shapes (flat and cylindrical) of the impacting surfaces. Average deviation of peak force from the 50th male to 95th male and 5th female were 6.4% and 10.6% considering impacts on the three impactors. These results indicate hierarchy of variables which can be used in injury mitigation efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Does Endoscopic Piriformis Tenotomy Provide Safe and Complete Tendon Release? A Cadaver Study.

    Science.gov (United States)

    Coulomb, Rémy; Khelifi, Anis; Bertrand, Martin; Mares, Olivier; May, Olivier; Marchand, Philippe; Kouyoumdjian, Pascal

    2018-05-28

    Endoscopic piriformis release (EPR) is among the available treatments for piriformis syndrome. This procedure typically involves dividing the muscle near the sciatic nerve in the sub-gluteal space, which contains numerous blood vessels and nerves. The objectives of this prospective cadaver study were: 1) to assess the reproducibility and quality of endoscopic piriformis tenotomy near the greater trochanter; 2) to detect iatrogenic injuries to the lateral hip rotators, nerves, and vessels; 3) and to define the surgical safety margins relative to the sciatic nerve and inferior gluteal bundle. EPR at the greater trochanter ensures full release of the muscle with a limited risk of neuro-vascular injury. EPR was performed via two portals on 10 cadaver hips preserved in zinc chloride and placed in the prone position. A third, ancillary portal was required in 7 cases. The area was then dissected with the Kocher-Langenbeck approach to allow an assessment of the tenotomy, detect iatrogenic injuries, and measure the distances separating the tenotomy site from the sciatic nerve and inferior gluteal artery. Complete tenotomy was achieved in 9 (90%) cases. The tendon adhered to the capsule in 2 (20%) cases and showed acquired avulsion in 1 case. No injuries to the sciatic nerve or inferior gluteal artery occurred. Mean distances from the tenotomy site were 5.21±0.59cm (range, 4.5-6.6cm) for the sciatic nerve and 7.1±0.89cm (range, 5.4-8.5cm) for the inferior gluteal artery. EPR by a tenotomy at the greater trochanter without sciatic nerve release provides full release of the muscle with satisfactory safety margins and a short learning curve. III, prospective cadaver case-control study. Copyright © 2018. Published by Elsevier Masson SAS.

  6. A new noninvasive controlled intra-articular ankle distraction technique on a cadaver model.

    Science.gov (United States)

    Aydin, Ahmet T; Ozcanli, Haluk; Soyuncu, Yetkin; Dabak, Tayyar K

    2006-08-01

    Effective joint distraction is crucial in arthroscopic ankle surgery. We describe an effective and controlled intra-articular ankle distraction technique that we have studied by means of a fresh-frozen cadaver model. Using a kyphoplasty balloon, which is currently used in spine surgery, we tried to achieve a controlled distraction. After the fixation of the cadaver model, standard anteromedial and anterolateral portals were used for ankle arthroscopy. From the same portals, the kyphoplasty balloon was inserted and placed in an appropriate position intra-articularly. The necessary amount of distraction was achieved by inflating the kyphoplasty balloon with a pressure regulation pump. All anatomic sites of the ankle joint were easily visualized with the arthroscope during surgery by changing the pressure and the intra-articular position of the kyphoplasty balloon. Ankle distraction was clearly seen on the arthroscopic and image intensifier view. The kyphoplasty balloon is simple to place through the standard portals and the advantage is that it allows easy manipulation of the arthroscopic instruments from the same portal.

  7. Evaluation of serosal patch supplementation of surgical anastomoses in intestinal segments from canine cadavers.

    Science.gov (United States)

    Hansen, Lane A; Monnet, Eric L

    2013-08-01

    To compare leakage and maximum intraluminal pressures of intestinal anastomoses with and without serosal patch supplementation in dogs. Healthy small intestine segments from cadavers of 2 dogs euthanized for reasons unrelated to the study. 12 enterectomy constructs were created by anastomosis of intestinal segments with a standard simple continuous suture pattern. Half of the constructs were randomly selected for additional serosal patch support. Leakage and maximum intraluminal pressures were measured in and compared between patch-supplemented and nonsupplemented constructs. Mean ± SD leakage pressure was significantly greater for the patch-supplemented anastomoses (81.8 ± 6.7 mm Hg) than for the nonsupplemented anastomoses (28.0 ± 6.7 mm Hg). Maximum intraluminal pressures were not significantly different between the groups. Serosal patch-supplemented anastomoses were able to sustain a significantly higher pressure before leakage than were nonsupplemented anastomoses in intestinal specimens from canine cadavers. The serosal patch supplementation may protect against leakage immediately after enterectomy in dogs.

  8. Multi-sector thermo-physiological head simulator for headgear research

    Science.gov (United States)

    Martinez, Natividad; Psikuta, Agnes; Corberán, José Miguel; Rossi, René M.; Annaheim, Simon

    2017-02-01

    A novel thermo-physiological human head simulator for headgear testing was developed by coupling a thermal head manikin with a thermo-physiological model. As the heat flux at head-site is directly measured by the head manikin, this method provides a realistic quantification of the heat transfer phenomena occurring in the headgear, such as moisture absorption-desorption cycles, condensation, or moisture migration across clothing layers. Before coupling, the opportunities of the head manikin for representing the human physiology were evaluated separately. The evaluation revealed reduced precision in forehead and face temperature predictions under extreme heterogeneous temperature distributions and no initial limitation for simulating temperature changes observed in the human physiology. The thermo-physiological model predicted higher sweat rates when applied for coupled than for pure virtual simulations. After coupling, the thermo-physiological human head simulator was validated using eight human experiments. It precisely predicted core, mean skin, and forehead temperatures with average rmsd values within the average experimental standard deviation (rmsd of 0.20 ± 0.15, 0.83 ± 0.34, and 1.04 ± 0.54 °C, respectively). However, in case of forehead, precision was lower for the exposures including activity than for the sedentary exposures. The representation of the human sweat evaporation could be affected by a reduced evaporation efficiency and the manikin sweat dynamics. The industry will benefit from this thermo-physiological human head simulator leading to the development of helmet designs with enhanced thermal comfort and, therefore, with higher acceptance by users.

  9. Multi-sector thermo-physiological head simulator for headgear research.

    Science.gov (United States)

    Martinez, Natividad; Psikuta, Agnes; Corberán, José Miguel; Rossi, René M; Annaheim, Simon

    2017-02-01

    A novel thermo-physiological human head simulator for headgear testing was developed by coupling a thermal head manikin with a thermo-physiological model. As the heat flux at head-site is directly measured by the head manikin, this method provides a realistic quantification of the heat transfer phenomena occurring in the headgear, such as moisture absorption-desorption cycles, condensation, or moisture migration across clothing layers. Before coupling, the opportunities of the head manikin for representing the human physiology were evaluated separately. The evaluation revealed reduced precision in forehead and face temperature predictions under extreme heterogeneous temperature distributions and no initial limitation for simulating temperature changes observed in the human physiology. The thermo-physiological model predicted higher sweat rates when applied for coupled than for pure virtual simulations. After coupling, the thermo-physiological human head simulator was validated using eight human experiments. It precisely predicted core, mean skin, and forehead temperatures with average rmsd values within the average experimental standard deviation (rmsd of 0.20 ± 0.15, 0.83 ± 0.34, and 1.04 ± 0.54 °C, respectively). However, in case of forehead, precision was lower for the exposures including activity than for the sedentary exposures. The representation of the human sweat evaporation could be affected by a reduced evaporation efficiency and the manikin sweat dynamics. The industry will benefit from this thermo-physiological human head simulator leading to the development of helmet designs with enhanced thermal comfort and, therefore, with higher acceptance by users.

  10. Surface Projection of Interosseous Foramen of the Leg: Cadaver Study

    Directory of Open Access Journals (Sweden)

    Eric Arguello

    2016-01-01

    Full Text Available Purpose. This study was conducted to identify the surface projection of the interosseous foramen and associated structures of the proximal leg using the average clinician’s thumb width as a quick measurement to assist in differential diagnosis and treatment. Methods. Twelve cadavers (5 males and 7 females, age range = 51–91 years, and mean age = 76.9 were dissected for analysis. Location and size of interosseous foramen, location of anterior tibial artery, location of deep fibular nerve, and corresponding arterial branches were measured and converted into thumb widths. Results. Mean thumb width measured among the cadavers was 17.94±3.9 mm. The interosseous foramen measured was approximately 1 thumb width vertically (18.47±3.0 mm and 1/2 thumb width horizontally (7.32±2.1 mm and was located approximately 1 thumb width distally to the tibial tuberosity (20.81±6.8 mm and 2 thumb widths (37.47±4.7 mm lateral to the tibial ridge. The anterior tibial artery and deep fibular nerve converged approximately 4 thumb widths (74.31±14.8 mm inferior to the tibial tuberosity and 2 thumb widths (33.46±4.9 mm lateral to the tibial ridge. Conclusion. Clinicians may identify anatomical structures of the proximal leg with palpation using the thumb width for measurement.

  11. Lengths and Positions of the Vermiform Appendix among Sudanese Cadavers

    Directory of Open Access Journals (Sweden)

    Ehab I. El-Amin

    2015-08-01

    Full Text Available Background/objective: The anatomy of vermiform appendix displays great variations in length and position between different populations. The reports relating these variations to a specific etiological factor are few. This study aims to describe the positions and lengths of vermiform appendix among Sudanese cadavers. Methods: This descriptive study was carried out in Omdurman Teaching Hospital Morgue and Omdurman Islamic University-Sudan. Sixty Sudanese cadavers (30 male and 30 female, were dissected in the period from June 2013 to June 2014. The positions and the lengths of vermiform appendix were measured in millimeters. The data was analyzed by SPSS version 20. Results: The cadavers’ age ranged between 20 to 80 years according to their medico-legal reports. Retrocaecal position was mainly observed in 60%, pelvic in 35%, post-ileal in 3.3%, and pre-ileal in 1.7%. The lengths of the appendix was found < 69 mm in 23.3%, 70-110 mm in 60%, and > 110 mm in 16.7%, also the study showed insignificant difference between the lengths and ages (p < 0.08, and between males and females (p = 0.23. Age was the influencing factor for the positions of vermiform appendixes (p = 0.04. Conclusion: The study showed that the commonest lengths of the appendix were 70-110 mm while the common position was retrocaecal regardless to age or gender. This data should be considered in surgical removal of the inflamed appendix.

  12. Infrared Non-Contact Head Sensor for Control of Wheelchair Movements

    DEFF Research Database (Denmark)

    Christensen, Henrik Vie; Garcia, Juan Carlos

    2005-01-01

    This paper presents a new human-machine interface for controlling a wheelchair by head movements. The position of the head is determined by use of infrared sensors, with no parts attached to the head of the user. The placement of the infrared sensors are behind the head of the user, so that the f......This paper presents a new human-machine interface for controlling a wheelchair by head movements. The position of the head is determined by use of infrared sensors, with no parts attached to the head of the user. The placement of the infrared sensors are behind the head of the user, so...

  13. The role of Human papillomavirus in head and neck cancer and the impact on radiotherapy outcome

    International Nuclear Information System (INIS)

    Lassen, Pernille

    2010-01-01

    The profound influence of Human papillomavirus (HPV) on the epidemiological pattern and clinical course of head and neck cancer (HNSCC) has led to a change in the traditional understanding of this disease entity. Separate therapeutic strategies based on tumour HPV status are under consideration and in this light provision of knowledge concerning the influence of tumour HPV on the radiation response in HNSCC appears highly relevant. This review provides a summary of the current understanding of the role of HPV in head and neck cancer with specific focus on the viral impact on radiotherapy outcome of HNSCC.

  14. Comparison of reliability of five patellar position indices at various stifle joint angles in pelvic limbs obtained from cadavers of red foxes (Vulpes vulpes)

    DEFF Research Database (Denmark)

    Miles, James E; Nielsen, Dorte H; Jensen, Bente Rona

    2012-01-01

    To compare 5 patellar position indices at various stifle joint angles in cadavers of red foxes, determine measurement reliability, and assess the suitability of these indices for clinical use.......To compare 5 patellar position indices at various stifle joint angles in cadavers of red foxes, determine measurement reliability, and assess the suitability of these indices for clinical use....

  15. The assessment of virtual reality for human anatomy instruction

    Science.gov (United States)

    Benn, Karen P.

    1994-01-01

    This research project seeks to meet the objective of science training by developing, assessing, and validating virtual reality as a human anatomy training medium. In ideal situations, anatomic models, computer-based instruction, and cadaver dissection are utilized to augment the traditional methods of instruction. At many institutions, lack of financial resources limits anatomy instruction to textbooks and lectures. However, human anatomy is three dimensional, unlike the one dimensional depiction found in textbooks and the two dimensional depiction found on the computer. Virtual reality is a breakthrough technology that allows one to step through the computer screen into a three dimensional world. This technology offers many opportunities to enhance science education. Therefore, a virtual testing environment of the abdominopelvic region of a human cadaver was created to study the placement of body parts within the nine anatomical divisions of the abdominopelvic region and the four abdominal quadrants.

  16. Arched abdominal aorta and altered course of right ovarian vessels in a female cadaver: Clinical significance and embryological explanation

    Directory of Open Access Journals (Sweden)

    Sneha Guruprasad Kalthur

    2013-01-01

    Full Text Available Variations in the vascular origin of ovarian artery have been reported in the past. However, the reports on altered course of ovarian artery are very few. In the present paper, we discuss about multiple variations observed in formalin fixed female cadaver. The right ovarian artery was 22 cm long and ran unusually behind the inferior vena cava (IVC. The right ovarian vein drained in to right renal vein at right angle instead of draining into IVC directly. In addition, to these variations, the cadaver had arched abdominal aorta and retro-aortic left renal vein.

  17. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model.

    Science.gov (United States)

    Somberg, Andrew Max; Whiteside, William K; Nilssen, Erik; Murawski, Daniel; Liu, Wei

    2016-03-01

    Many types of screws, plates, and strut grafts have been utilized for ankle arthrodesis. Biomechanical testing has shown that these constructs can have variable stiffness. More recently, headless compression screws have emerged as an evolving method of achieving compression in various applications but there is limited literature regarding ankle arthrodesis. The aim of this study was to determine the biomechanical stability provided by a second generation fully threaded headless compression screw compared to a standard headed, partially threaded cancellous screw in a cadaveric ankle arthrodesis model. Twenty fresh frozen human cadaver specimens were subjected to simulated ankle arthrodesis with either three standard cancellous-bone screws (InFix 7.3mm) or with three headless compression screws (Acumed Acutrak 2 7.5mm). The specimens were subjected to cyclic loading and unloading at a rate of 1Hz, compression of 525 Newtons (N) and distraction of 20N for a total of 500 cycles using an electromechanical load frame (Instron). The amount of maximum distraction was recorded as well as the amount of motion that occurred through 1, 10, 50, 100, and 500 cycles. No significant difference (p=0.412) was seen in the amount of distraction that occurred across the fusion site for either screw. The average maximum distraction after 500 cycles was 201.9μm for the Acutrak 2 screw and 235.4μm for the InFix screw. No difference was seen throughout each cycle over time for the Acutrak 2 screw (p-value=0.988) or the InFix screw (p-value=0.991). Both the traditional InFix type screw and the second generation Acumed Acutrak headless compression screws provide adequate fixation during ankle arthrodesis under submaximal loads. There is no demonstrable difference between traditional cannulated partially threaded screws and headless compression screws studied in this model. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  18. Evaluation of diode endoscopic cyclophotocoagulation in bovine cadaver eyes.

    Science.gov (United States)

    Harrington, Jay T; McMullen, Richard J; Cullen, John M; Gilger, Brian C

    2012-09-01

    To evaluate the anterior chamber approach and energy levels for endoscopic cyclophotocoagulation (ECPC) and assess ECPC-induced tissue damage in phakic eyes of bovine cadavers. 12 bovine cadaver eyes. Angle of reach was measured in 6 eyes following placement of a curved endoscopic probe through multiple corneal incisions. In another 6 eyes, each ocular quadrant underwent ECPC at 1 of 3 energy levels (0.75, 0.90, and 1.05 J) or remained untreated. Visible effects on tissues (whitening and contraction of ciliary processes) were scored (scale of 0 [no effects] to 6 [severe effects]), and severity and extent of histologic damage to the pigmented and nonpigmented ciliary epithelium and fibromuscular stroma were each scored (scale of 0 [no effect] to 3 [severe effect]) and summed for each quadrant. Overall mean scores for 6 quadrants/treatment were calculated. Mean ± SD combined angle of reach was 148 ± 24° (range, 123 ± 23° [ventromedial] to 174 ± 11° [dorsolateral]). At the 0.75-, 0.90-, and 1.05-J levels, mean visible tissue effect scores were 3.12 ± 0.47, 3.86 ± 0.35, and 4.68 ± 0.58, respectively; mean histologic damage scores were 4.79 ± 1.38 (mild damage), 6.82 ± 1.47 (moderate damage), and 9.37 ± 1.42 (severe damage), respectively. Occasional popping noises (venting of vaporized interstitial water) were heard at the 1.05-J level. Multiple incisions were necessary to facilitate 360° ECPC treatment in bovine eyes. For ECPC in vivo, the 0.75- and 0.90-J energy levels had the potential to effectively treat the ciliary epithelium.

  19. Morphology and morphometry of the ulnar head of the pronator teres muscle in relation to median nerve compression at the proximal forearm.

    Science.gov (United States)

    Gurses, I A; Altinel, L; Gayretli, O; Akgul, T; Uzun, I; Dikici, F

    2016-12-01

    The pronator syndrome is a rare compression neuropathy of the median nerve. Ulnar head of the pronator teres muscle may cause compression at proximal forearm. Detailed morphologic and morphometric studies on the anatomy of the ulnar head of pronator teres is scarce. We dissected 112 forearms of fresh cadavers. We evaluated the morphology and morphometry of the ulnar head of pronator teres muscle. The average ulnar head width was 16.3±8.2mm. The median nerve passed anterior to the ulnar head at a distance of 50.4±10.7mm from the interepicondylar line. We classified the morphology of the ulnar head into 5 types. In type 1, the ulnar head was fibromuscular in 60 forearms (53.6%). In type 2, it was muscular in 23 forearms (20.5%). In type 3, it was just a fibrotic band in 18 forearms (16.1%). In type 4, it was absent in 9 forearms (8%). In type 5, the ulnar head had two arches in 2 forearms (1.8%). In 80 forearms (71.5%: types 1, 3, and 5), the ulnar head was either fibromuscular or a fibrotic band. Although the pronator syndrome is a rare compression syndrome, the ulnar head of pronator teres is reported as the major cause of entrapment in the majority of the cases. The location of the compression of the median nerve in relation to the ulnar head of pronator teres muscle and the morphology of the ulnar head is important for open or minimally-invasive surgical treatment. Sectional study. Basic science study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Diagnostics of femoral head status in humans using laser spectroscopy - In vitro studies.

    Science.gov (United States)

    Lin, Huiying; Li, Wansha; Zhang, Hao; Chen, Peng; Chen, Delong; He, Wei; Svanberg, Sune; Svanberg, Katarina

    2017-10-01

    Osteonecrosis of the femoral head (ONFH), a recalcitrant and disabling disease, is caused by inadequate or fully disrupted blood supply to the affected segment of the subchondral bone. Theoretically, there will develop gas-filled pores during the bone decay process due to lacking blood supply. Unfortunately, the relationship between the gas-filled pores and ONFH is still unclear. Here, we have introduced diode laser absorption spectroscopy to detect oxygen and water vapor signals in the femoral heads from hip replacement in 19 patients. Five samples are affected by osteoarthritis (OA) and the others are related to ONFH. Oxygen and water vapor signals could be obtained, demonstrating the presence of gas-filled pores in both the OA and ONFH groups while the measurement results showed no significant difference. A study of gas exchange was also performed on one excised bone sample to study how these gas pores communicate with the ambient air. The results suggested that the obtained oxygen signals inside the bone samples originate from the invasion of ambient air, which is not expected in vivo. In conclusion, the ability to detect the gas signal of laser absorption spectroscopy shows the potential for the medical application of assessing the human femoral head in vivo. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Radio frequency-induced temperature elevations in the human head considering small anatomical structures

    International Nuclear Information System (INIS)

    Schmid, G.; Ueberbacher, R.; Samaras, T.

    2007-01-01

    In order to enable a detailed numerical radio frequency (RF) dosimetry and the computations of RF-induced temperature elevations, high-resolution (0.1 mm) numerical models of the human eye, the inner ear organs and the pineal gland were developed and inserted into a commercially available head model. As radiation sources, generic models of handsets at 400, 900 and 1850 MHz operating in close proximity to the head were considered. The results, obtained by finite-difference time domain-based computations, showed a highly heterogeneous specific absorption rate (SAR) distribution and SAR-peaks inside the inner ear structures; however, the corresponding RF-induced temperature elevations were well below 0.1 deg. C, when considering typical output power values of hand-held devices. In case of frontal exposure, with the radiation sources ∼2.5 cm in front of the closed eye, maximum temperature elevations in the eye in the range of ∼0.2-0.6 deg. C were found for typical device output powers. A reduction in tissue perfusion mainly affected the maximum RF-induced temperature elevation of tissues deep inside the head. Similarly, worst-case considerations regarding pulsed irradiation affected temperature elevations in deep tissue significantly more than in superficial tissues. (authors)

  2. Normal mediastinal lymph node size and shape; CT and cadaver study

    International Nuclear Information System (INIS)

    Im, Chung Kie; Lee, Kyung Soo; Han, Man Chung; Kim, Chu Wan

    1985-01-01

    With the view point of size, shape and arrangement pattern, authors present normal mediastinal lymph node from the analysis of 61 cases of CT scan and multidirectional section of 2 cadavers. The result were as follows: 1. Transverse diameter of the lymph nodes, demonstrated in cadaver section, was 3 to 6mm in upper paratracheal area and 5 to 14mm in juxta-carinal and AP-window area. Arrangement of the lymph nodes showed tendency of longitudinal direction in lower paratracheal, and juxtacarinal area, while that of AP window showed tendency of AP direction as long axis. 2. Mean and the largest size of the lymph nodes demonstrated in CT scan were 3.7mm, 8mm in upper paratracheal area, and 6mm, 12mm in lower paratracheal area, and 7.1mm, 14mm in juxtacarinal area, and 6.3mm and 11mm in aorticopulmonary window area. 3. Size of the lymph nodes in CT scan showed linear increasing tendency according to increasing age (y=0.32, p<0.005). 4. Shape of the lymph nodes in CT scan were mostly round in upper paratracheal area while that of aorticopulmonary window showed higher incidence of oval and elongated shape. 5. Recommended size criterior of abnormal lymph node is 10mm in upper paratracheal area and 15mm in the other area

  3. MORPHOMETRIC ANALYSIS OF CORPUS CALLOSUM- A STUDY IN CADAVER AND MRI

    Directory of Open Access Journals (Sweden)

    Ambili Puthanveetil

    2017-07-01

    Full Text Available BACKGROUND The Corpus Callosum (CC can best be seen in the mid-sagittal section of brain both in cadaver and MRI. The morphometric measurements of the same will be of use in neurosurgical procedures. Sexual dimorphism and the age-related changes in its measurements remained controversial. Till date, no studies have been done on corpus callosum in Kerala. MATERIALS AND METHODS Measurements of CC has been taken and studied in detail in 24 formalin fixed brains from the Department of Anatomy and 48 MR images from the Department of Radiology. The changes according to age and sex were analysed. RESULTS The mean length of CC in the cadaver was 7.24 cm, which was 3.38 cm posterior to frontal pole and 5.73 cm anterior to occipital pole. In MR images, the mean length was 7.10 in males and 6.76 in females. The difference we got was not statistically significant. The length increased with age. Thickness of genu and body decreased as the age advances, but the splenial thickness was found to be increasing with age. There was significant correlation between the thicknesses of various parts of CC. CONCLUSION The values were almost similar to those in the previous studies. Morphometrically, a significant gender difference was not identified in the present study. There were changes according to age both in males and females.

  4. Forced oral opening for cadavers with rigor mortis: two approaches for the myotomy on the temporal muscles.

    Science.gov (United States)

    Nakayama, Y; Aoki, Y; Niitsu, H; Saigusa, K

    2001-04-15

    Forensic dentistry plays an essential role in personal identification procedures. An adequate interincisal space of cadavers with rigor mortis is required to obtain detailed dental findings. We have developed intraoral and two directional approaches, for myotomy of the temporal muscles. The intraoral approach, in which the temporalis was dissected with scissors inserted via an intraoral incision, was adopted for elderly cadavers, females and emaciated or exhausted bodies, and had a merit of no incision on the face. The two directional approach, in which myotomy was performed with thread-wire saw from behind and with scissors via the intraoral incision, was designed for male muscular youths. Both approaches were effective to obtain a desired degree of an interincisal opening without facial damage.

  5. Porcine cadaver organ or virtual-reality simulation training for laparoscopic cholecystectomy: a randomized, controlled trial.

    Science.gov (United States)

    Van Bruwaene, Siska; Schijven, Marlies P; Napolitano, Daniel; De Win, Gunter; Miserez, Marc

    2015-01-01

    As conventional laparoscopic procedural training requires live animals or cadaver organs, virtual simulation seems an attractive alternative. Therefore, we compared the transfer of training for the laparoscopic cholecystectomy from porcine cadaver organs vs virtual simulation to surgery in a live animal model in a prospective randomized trial. After completing an intensive training in basic laparoscopic skills, 3 groups of 10 participants proceeded with no additional training (control group), 5 hours of cholecystectomy training on cadaver organs (= organ training) or proficiency-based cholecystectomy training on the LapMentor (= virtual-reality training). Participants were evaluated on time and quality during a laparoscopic cholecystectomy on a live anaesthetized pig at baseline, 1 week (= post) and 4 months (= retention) after training. All research was performed in the Center for Surgical Technologies, Leuven, Belgium. In total, 30 volunteering medical students without prior experience in laparoscopy or minimally invasive surgery from the University of Leuven (Belgium). The organ training group performed the procedure significantly faster than the virtual trainer and borderline significantly faster than control group at posttesting. Only 1 of 3 expert raters suggested significantly better quality of performance of the organ training group compared with both the other groups at posttesting (p virtual trainer group did not outperform the control group at any time. For trainees who are proficient in basic laparoscopic skills, the long-term advantage of additional procedural training, especially on a virtual but also on the conventional organ training model, remains to be proven. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  6. Heads Up: Concussion in Youth Sports

    Medline Plus

    Full Text Available ... with HEADS UP & CDC's Injury Center HEADS UP Resources File Formats Help: How do I view different ... 6348 Email CDC-INFO U.S. Department of Health & Human Services HHS/Open USA.gov Top

  7. The Use of Specially Designed Tasks to Enhance Student Interest in the Cadaver Dissection Laboratory

    Science.gov (United States)

    Kang, Seok Hoon; Shin, Jwa-Seop; Hwang, Young-il

    2012-01-01

    Cadaver dissection is a key component of anatomy education. Unfortunately, students sometimes regard the process of dissection as uninteresting or stressful. To make laboratory time more interesting and to encourage discussion and collaborative learning among medical students, specially designed tasks were assigned to students throughout…

  8. Humanoid Robot Head Design Based on Uncanny Valley and FACS

    Directory of Open Access Journals (Sweden)

    Jizheng Yan

    2014-01-01

    Full Text Available Emotional robots are always the focus of artificial intelligence (AI, and intelligent control of robot facial expression is a hot research topic. This paper focuses on the design of humanoid robot head, which is divided into three steps to achieve. The first step is to solve the uncanny valley about humanoid robot, to find and avoid the relationship between human being and robot; the second step is to solve the association between human face and robot head; compared with human being and robots, we analyze the similarities and differences and explore the same basis and mechanisms between robot and human analyzing the Facial Action Coding System (FACS, which guides us to achieve humanoid expressions. On the basis of the previous two steps, the third step is to construct a robot head; through a series of experiments we test the robot head, which could show some humanoid expressions; through human-robot interaction, we find people are surprised by the robot head expression and feel happy.

  9. Refinements of the radiographic cadaver injection technique for investigating minute lymphatic vessels.

    Science.gov (United States)

    Suami, Hiroo; Taylor, G Ian; O'Neill, Jennifer; Pan, Wei-Ren

    2007-07-01

    The authors previously reported a new technique with which to delineate the lymphatic vessels, using hydrogen peroxide to identify them and a lead oxide suspension to demonstrate them on radiographs. This technique provided excellent studies of the lymph vessels in human cadavers, but there was still room for improvement. Lymph collecting vessels run superficially in some regions, where they may be damaged while the surgeon is attempting to find them. Vessels smaller than 0.3 mm in diameter could not be cannulated with a 30-gauge needle, which was the smallest the authors had available, and the lead oxide suspension often blocked this cannula. The authors also encountered problems holding the cannula steady. The authors solved these problems by using a mixture of hydrogen peroxide and ink to better identify the lymphatics, an extruded glass tube instead of a metal needle to cannulate them, an agate pestle and mortar to grind the lead oxide into finer particles, powdered milk to suspend the lead oxide, and a micromanipulator to facilitate accurate and steady cannulation of the vessels. This study developed these modifications to focus on tributaries of the collecting lymphatic channels that are smaller than 0.3 mm in diameter.

  10. Distribution of sensory nerve endings around the human sinus tarsi: a cadaver study

    Science.gov (United States)

    Rein, Susanne; Manthey, Suzanne; Zwipp, Hans; Witt, Andreas

    2014-01-01

    The aim of this study was to analyse the pattern of sensory nerve endings and blood vessels around the sinus tarsi. The superficial and deep parts of the fat pads at the inferior extensor retinaculum (IER) as well as the subtalar joint capsule inside the sinus tarsi from 13 cadaver feet were dissected. The distribution of the sensory nerve endings and blood vessels were analysed in the resected specimens as the number per cm2 after staining with haematoxylin-eosin, S100 protein, low-affinity neurotrophin receptor p75, and protein gene product 9.5 using the classification of Freeman and Wyke. Free nerve endings were the predominant sensory ending (P < 0.001). Ruffini and Golgi-like endings were rarely found and no Pacini corpuscles were seen. Significantly more free nerve endings (P < 0.001) and blood vessels (P = 0.01) were observed in the subtalar joint capsule than in the superficial part of the fat pad at the IER. The deep part of the fat pad at the IER had significantly more blood vessels than the superficial part of the fat pad at the IER (P = 0.012). Significantly more blood vessels than free nerve endings were seen in all three groups (P < 0.001). No significant differences in distribution were seen in terms of right or left side, except for free nerve endings in the superficial part of the fat pad at the IER (P = 0.003). A greater number of free nerve endings correlated with a greater number of blood vessels. The presence of sensory nerve endings between individual fat cells supports the hypothesis that the fat pad has a proprioceptive role monitoring changes and that it is a source of pain in sinus tarsi syndrome due to the abundance of free nerve endings. PMID:24472004

  11. SAR analysis of a needle type applicator made from a shape memory alloy using 3-D anatomical human head model

    International Nuclear Information System (INIS)

    Kubo, Mitsunori; Mimoto, Naoki; Hirashima, Taku; Morita, Emi; Shindo, Yasuhiro; Kato, Kazuo; Takahashi, Hideaki; Uzuka, Takeo; Fujii, Yukihiko

    2009-01-01

    This paper describes the possibility of a new heating method with a needle applicator made of a shape memory alloy (SMA) to expand the heating area for interstitial brain tumor hyperthermia treatments. The purpose of the study described here is to show the capability of the method to expand a defined heating region with the developed three-dimensional (3-D) anatomical human head model using the finite element method (FEM). One major disadvantage of radiofrequency (RF) interstitial hyperthermia treatment is that this heating method has a small heating area. To overcome this problem, a new type of needle made of a SMA was developed. The specific absorption rate (SAR) distributions of this proposed method, when applied to the 3-D anatomical human head model reconstructed from two-dimensional (2-D) MRI and X-ray CT images, were calculated with computer simulations. The calculated SAR distributions showed no unexpected hot spots within the model. The heated area was localized around the tumor. These results suggest that the proposed heating method using the SMA needle applicator and the developed method for reconstructing a 3-D anatomical human head model are capable of being used for invasive brain tumor hyperthermia treatments. (author)

  12. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    Science.gov (United States)

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  13. Optical clearing of vaginal tissues in cadavers

    Science.gov (United States)

    Chang, Chun-Hung; Hardy, Luke A.; Peters, Michael G.; Bastawros, Dina A.; Myers, Erinn M.; Kennelly, Michael J.; Fried, Nathaniel M.

    2018-02-01

    A nonsurgical laser procedure is being developed for treatment of female stress urinary incontinence (SUI). Previous studies in porcine vaginal tissues, ex vivo, as well as computer simulations, showed the feasibility of using near-infrared laser energy delivered through a transvaginal contact cooling probe to thermally remodel endopelvic fascia, while preserving the vaginal wall from thermal damage. This study explores optical properties of vaginal tissue in cadavers as an intermediate step towards future pre-clinical and clinical studies. Optical clearing of tissue using glycerol resulted in a 15-17% increase in optical transmission after 11 min at room temperature (and a calculated 32.5% increase at body temperature). Subsurface thermal lesions were created using power of 4.6 - 6.4 W, 5.2-mm spot, and 30 s irradiation time, resulting in partial preservation of vaginal wall to 0.8 - 1.1 mm depth.

  14. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy

    Energy Technology Data Exchange (ETDEWEB)

    Paech, Daniel [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany); Giesel, Frederik L. [University Hospital Heidelberg, Department of Nuclear Medicine, Heidelberg (Germany); Unterhinninghofen, Roland [Institute of Anthropomatics, Karlsruhe Institute of Technology, Karlsruhe (Germany); Schlemmer, Heinz-Peter [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Kuner, Thomas; Doll, Sara [Heidelberg University, Institute of Anatomy and Cell Biology, Heidelberg (Germany)

    2017-05-15

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n{sub 1} = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n{sub 2} = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n{sub 3} = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. circle Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. (orig.)

  15. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy

    International Nuclear Information System (INIS)

    Paech, Daniel; Giesel, Frederik L.; Unterhinninghofen, Roland; Schlemmer, Heinz-Peter; Kuner, Thomas; Doll, Sara

    2017-01-01

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n_1 = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n_2 = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n_3 = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p < 0.001). The incorporation of cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. circle Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. (orig.)

  16. Conceiving Human Interaction by Visualising Depth Data of Head Pose Changes and Emotion Recognition via Facial Expressions

    Directory of Open Access Journals (Sweden)

    Grigorios Kalliatakis

    2017-07-01

    Full Text Available Affective computing in general and human activity and intention analysis in particular comprise a rapidly-growing field of research. Head pose and emotion changes present serious challenges when applied to player’s training and ludology experience in serious games, or analysis of customer satisfaction regarding broadcast and web services, or monitoring a driver’s attention. Given the increasing prominence and utility of depth sensors, it is now feasible to perform large-scale collection of three-dimensional (3D data for subsequent analysis. Discriminative random regression forests were selected in order to rapidly and accurately estimate head pose changes in an unconstrained environment. In order to complete the secondary process of recognising four universal dominant facial expressions (happiness, anger, sadness and surprise, emotion recognition via facial expressions (ERFE was adopted. After that, a lightweight data exchange format (JavaScript Object Notation (JSON is employed, in order to manipulate the data extracted from the two aforementioned settings. Motivated by the need to generate comprehensible visual representations from different sets of data, in this paper, we introduce a system capable of monitoring human activity through head pose and emotion changes, utilising an affordable 3D sensing technology (Microsoft Kinect sensor.

  17. Conceiving Human Interaction by Visualising Depth Data of Head Pose Changes and Emotion Recognition via Facial Expressions

    NARCIS (Netherlands)

    Kalliatakis, Grigorios; Stergiou, A.G.; Vidakis, Nikolaos

    2017-01-01

    Affective computing in general and human activity and intention analysis in particular comprise a rapidly-growing field of research. Head pose and emotion changes present serious challenges when applied to player’s training and ludology experience in serious games, or analysis of customer

  18. Evaluation of a novel suture material for closure of intestinal anastomoses in canine cadavers.

    Science.gov (United States)

    Hansen, Lane A; Monnet, Eric L

    2012-11-01

    To compare leakage and maximum intraluminal pressures for a novel suture material with pressures for comparable suture material when used in closure of intestinal anastomoses in canine cadavers. Healthy intestines from cadavers of dogs euthanized for reasons unrelated to the study. 18 anastomoses were performed on intestinal sections within 72 hours after dogs were euthanized and intestinal samples collected. Anastomoses were performed with a simple continuous suture pattern. Leakage and maximum intraluminal pressures were measured and recorded for 6 control segments and 18 anastomosed sections. A barbed glycomer 631 suture (size 4-0 United States Pharmacopeia [USP]) was compared with glycomer 631 sutures (sizes 3-0 and 4-0 USP). Results for leakage and maximum intraluminal pressures were compared via an ANOVA. The barbed glycomer 631 suture material leaked at a significantly higher pressure than did the comparable glycomer 631 suture materials. Maximum intraluminal pressures were not significantly different among the suture materials. Barbed glycomer 631 4-0 USP suture material was as effective as glycomer 631 suture materials and may be a safe alternative for use in closure of enterectomies in dogs.

  19. Surgical dummy: a surrogate to live animal in teaching Veterinary ...

    African Journals Online (AJOL)

    The ethos of the course veterinary surgery is to install core surgical skills at the very start of a ... 2d to 4d nail gauges with large nail head. Cadaver ... Teaching model. Virtual surgery. Dummy. Cadaver. Live animal. Motor skill. -. ++. ++. ++.

  20. Trichostatin A, a histone deacetylase inhibitor, potentiated cytotoxic effect of lionizing radiation in human head and neck cancer cell lines

    International Nuclear Information System (INIS)

    Kim, Jin Ho; Shin, Jin Hee; Chie, Eui Kyu; Wu, Hong Gyun; Kim, Jae Sung; Kim, Il Han; Ha, Sung Whan; Park, Charn Il; Kang, Wee Saing

    2004-01-01

    We have previously reported that human glioblastoma cells are sensitized to radiation-induced death after their exposure to trichostatin A (TSA), a histone deacetylase inhibitor (HDAC-I), prior to the irradiation. We aimed to measure the magnitude of the radiosensitizing effect of TSA in human head and neck cancer cell lines. human head and neck cancer cell lines, HN-3 and HN-9, were exposed to 0, 50, 100, and 200 nM TSA for 18 hr prior to irradiation. Then, the TSA-treated cells were irradiated with 0, 2, 4, 6, and 8 Gy, and cell survival was measured by clonogenic assay. Pre-irradiation exposure to TSA was found to radiosensitize HN-3 and HN-9 cell lines. In HN-9 cells, the fraction surviving after 2 Gy (SF2) was significantly reduced by treatment of TSA at concentration as low as 50 nM. However, a treatment with 200 nM TSA was required to significantly decrease SF2 in the HN-3 cell line. SER of pre-irradiation treatment with 200 nM TSA was 1.84 in HN-3 and 7.24 in HN-9, respectively. Our results clearly showed that human head and neck cancer cell lines can be sensitized to ionizing radiation by pre-irradiation inhibition of histone deacetylase (HDAC) using TSA, and that this potentiation might well be a general phenomenon

  1. Thermal effects of dorsal head immersion in cold water on nonshivering humans.

    Science.gov (United States)

    Giesbrecht, Gordon G; Lockhart, Tamara L; Bristow, Gerald K; Steinman, Allan M

    2005-11-01

    Personal floatation devices maintain either a semirecumbent flotation posture with the head and upper chest out of the water or a horizontal flotation posture with the dorsal head and whole body immersed. The contribution of dorsal head and upper chest immersion to core cooling in cold water was isolated when the confounding effect of shivering heat production was inhibited with meperidine (Demerol, 2.5 mg/kg). Six male volunteers were immersed four times for up to 60 min, or until esophageal temperature = 34 degrees C. An insulated hoodless dry suit or two different personal floatation devices were used to create four conditions: 1) body insulated, head out; 2) body insulated, dorsal head immersed; 3) body exposed, head (and upper chest) out; and 4) body exposed, dorsal head (and upper chest) immersed. When the body was insulated, dorsal head immersion did not affect core cooling rate (1.1 degrees C/h) compared with head-out conditions (0.7 degrees C/h). When the body was exposed, however, the rate of core cooling increased by 40% from 3.6 degrees C/h with the head out to 5.0 degrees C/h with the dorsal head and upper chest immersed (P immersed (approximately 10%). The exaggerated core cooling during dorsal head immersion (40% increase) may result from the extra heat loss affecting a smaller thermal core due to intense thermal stimulation of the body and head and resultant peripheral vasoconstriction. Dorsal head and upper chest immersion in cold water increases the rate of core cooling and decreases potential survival time.

  2. Development of a child head analytical dynamic model considering cranial nonuniform thickness and curvature - Applying to children aged 0-1 years old.

    Science.gov (United States)

    Li, Zhigang; Ji, Cheng; Wang, Lishu

    2018-07-01

    Although analytical models have been used to quickly predict head response under impact condition, the existing models generally took the head as regular shell with uniform thickness which cannot account for the actual head geometry with varied cranial thickness and curvature at different locations. The objective of this study is to develop and validate an analytical model incorporating actual cranial thickness and curvature for child aged 0-1YO and investigate their effects on child head dynamic responses at different head locations. To develop the new analytical model, the child head was simplified into an irregular fluid-filled shell with non-uniform thickness and the cranial thickness and curvature at different locations were automatically obtained from CT scans using a procedure developed in this study. The implicit equation of maximum impact force was derived as a function of elastic modulus, thickness and radius of curvature of cranium. The proposed analytical model are compared with cadaver test data of children aged 0-1 years old and it is shown to be accurate in predicting head injury metrics. According to this model, obvious difference in injury metrics were observed among subjects with the same age, but different cranial thickness and curvature; and the injury metrics at forehead location are significant higher than those at other locations due to large thickness it owns. The proposed model shows good biofidelity and can be used in quickly predicting the dynamics response at any location of head for child younger than 1 YO. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. TCGA head Neck

    Science.gov (United States)

    Investigators with The Cancer Genome Atlas (TCGA) Research Network have discovered genomic differences – with potentially important clinical implications – in head and neck cancers caused by infection with the human papillomavirus (HPV).

  4. Rural neurosurgical and spinal laboratory setup.

    Science.gov (United States)

    Smith, Adam; Gagliardi, Filippo; Pelzer, Nicholas Robert; Hampton, Jacob; Chau, Anthony Minh Tien; Stewart, Fiona; Mortini, Pietro; Gragnaniello, Cristian

    2015-12-01

    Increasing focus has been placed on the use of simulation in neurosurgical and spinal surgical training worldwide, with the establishment of many surgical laboratories dedicated to such purpose. So far, the opportunities for hands-on cadaveric training in the areas of neurosurgery and spine surgery remain limited in Australia, owing to various factors, including the abolition of dissection in many medical schools, high maintenance requirements and widespread geographical distribution of surgical trainees. We established a cadaver-based neurosurgical laboratory based at the medical school of the University of New England in Armidale, Australia, which is used by the surgical dissection course for junior surgical trainees offered by the university. We reported our experiences in setting up a neurosurgical research laboratory, and explored the feasibility of establishing a cost-effective anatomical research facility in a rural setting in Australia. We found that Genelyn(TM)-fixed cadavers had limited movements of the head as required for adequate surgical positioning and exposure. Furthermore, we discovered that bodies embalmed via the femoral vein had poorly perfused heads after surgical exposure, and thus decapitation had to be performed unfortunately for our purpose. Cadaver samples and surgical equipment were sourced from various veterinary practices and commercial companies. Using human and animal cadavers, this laboratory provided trainees with hands-on opportunities to improve their surgical skills and neuroanatomical knowledge, as well as develop familiarity with highly specialized surgical equipment. We demonstrated the feasibility of establishing a cost-effective neurosurgical research laboratory in Australia and discussed various aspects of its maintenance.

  5. Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery

    International Nuclear Information System (INIS)

    Bachar, G.; Siewerdsen, J. H.; Daly, M. J.; Jaffray, D. A.; Irish, J. C.

    2007-01-01

    The image quality and localization accuracy for C-arm tomosynthesis and cone-beam computed tomography (CBCT) guidance of head and neck surgery were investigated. A continuum in image acquisition was explored, ranging from a single exposure (radiograph) to multiple projections acquired over a limited arc (tomosynthesis) to a full semicircular trajectory (CBCT). Experiments were performed using a prototype mobile C-arm modified to perform 3D image acquisition (a modified Siemens PowerMobil). The tradeoffs in image quality associated with the extent of the source-detector arc (θ tot ), the number of projection views, and the total imaging dose were evaluated in phantom and cadaver studies. Surgical localization performance was evaluated using three cadaver heads imaged as a function of θ tot . Six localization tasks were considered, ranging from high-contrast feature identification (e.g., tip of a K-wire pointer) to more challenging soft-tissue delineation (e.g., junction of the hard and soft palate). Five head and neck surgeons and one radiologist participated as observers. For each localization task, the 3D coordinates of landmarks pinpointed by each observer were analyzed as a function of θ tot . For all tomosynthesis angles, image quality was highest in the coronal plane, whereas sagittal and axial planes exhibited a substantial decrease in spatial resolution associated with out-of-plane blur and distortion. Tasks involving complex, lower-contrast features demonstrated steeper degradation with smaller tomosynthetic arc. Localization accuracy in the coronal plane was correspondingly high, maintained to tot ∼30 deg. , whereas sagittal and axial localization degraded rapidly below θ tot ∼60 deg. . Similarly, localization precision was better than ∼1 mm within the coronal plane, compared to ∼2-3 mm out-of-plane for tomosynthesis angles below θ tot ∼45 deg. . An overall 3D localization accuracy of ∼2.5 mm was achieved with θ tot ∼ 90 deg. for most

  6. How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    DEFF Research Database (Denmark)

    Janta, Iustina; Morán, Julio; Naredo, Esperanza

    2016-01-01

    between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned......To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance...... a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1...

  7. A Novel Cellular Handset Design for an Enhanced Antenna Performance and a Reduced SAR in the Human Head

    Directory of Open Access Journals (Sweden)

    Salah I. Al-Mously

    2008-01-01

    Full Text Available This paper presents a novel cellular handset design with a bottom-mounted short loaded-whip antenna. This new handset design is modeled and simulated using a finite difference time-domain (FDTD-based platform SEMCAD. The proposed handset is based on a current commercially available bar-phone type with a curvature shape, keypad positioned above the screen, and top-mounted antenna. The specific absorption rates (SARs are determined computationally in the specific anthropomorphic mannequin (SAM and anatomically correct model of a human head when exposed to the EM-field radiation of the proposed cellular handset and the handset with top-mounted antenna. The two cellular handsets are simulated to operate at both GSM standards, 900 MHz as well as 1800 MHz, having different antenna dimensions and intput power of 0.6 W and 0.125 W, respectively. The proposed human hand holding the two handset models is a semirealistic hand model consists of three tissues: skin, muscle, and bone. The simulations are conducted with handset positions based on the IEEE standard 1528-2003. The results show that the proposed handset has a significant improvement of antenna efficiency when it is hand-held close to head, as compared with the handset of top-mounted antenna. Also, the results show that a significant reduction of the induced SAR in the human head-tissues can be achieved with the proposed handset.

  8. Comparison between Hybrid III dummy and cadaver knee response in frontal impact

    OpenAIRE

    MASSON, Catherine; CAVALLERO, Claude

    2003-01-01

    Lower limb injuries frequently occur during car accidents. The purpose of this work was to compare the response of the hybrid iii lower limb with the response of cadaver lower limb subjected to similar impacts. These experiments were performed with the objective to evaluate the biofidelity, repeatability and response characteristics of the knee-femur-pelvis HIII dummy. The tests have examined the dynamic response of the knee-femur-pelvis complex to sub injury simple pendulum impacts. The expe...

  9. How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    Science.gov (United States)

    Janta, Iustina; Morán, Julio; Naredo, Esperanza; Nieto, Juan Carlos; Uson, Jacqueline; Möller, Ingrid; Bong, David; Bruyn, George A W; D Agostino, Maria Antonietta; Filippucci, Emilio; Hammer, Hilde Berner; Iagnocco, Annamaria; Terslev, Lene; González, Jorge Murillo; Mérida, José Ramón; Carreño, Luis

    2016-06-01

    To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions.

  10. Development of a fresh cadaver model for instruction of ultrasound-guided breast biopsy during the surgery clerkship: pre-test and post-test results among third-year medical students.

    Science.gov (United States)

    McCrary, Hilary C; Krate, Jonida; Savilo, Christine E; Tran, Melissa H; Ho, Hang T; Adamas-Rappaport, William J; Viscusi, Rebecca K

    2016-11-01

    The aim of our study was to determine if a fresh cadaver model is a viable method for teaching ultrasound (US)-guided breast biopsy of palpable breast lesions. Third-year medical students were assessed both preinstruction and postinstruction on their ability to perform US-guided needle aspiration or biopsy of artificially created masses using a 10-item checklist. Forty-one third-year medical students completed the cadaver laboratory as part of the surgery clerkship. Eight items on the checklist were found to be significantly different between pre-testing and post-testing. The mean preinstruction score was 2.4, whereas the mean postinstruction score was 7.10 (P cadaver models have been widely used in medical education. However, there are few fresh cadaver models that provide instruction on procedures done in the outpatient setting. Our model was found to be an effective method for the instruction of US-guided breast biopsy among medical students. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. First survey of forensically important insects from human corpses in Shiraz, Iran.

    Science.gov (United States)

    Moemenbellah-Fard, Mohammad D; Keshavarzi, Davood; Fereidooni, Mehran; Soltani, Aboozar

    2018-02-01

    The presence of insects on human cadavers has potential judicial value in medicolegal cases. This research emphasized the important role of insects in postmortem decomposition. It was conducted to investigate the composition and abundance of insects from human corpses during autopsies in legal medicine. It was implemented in the city of Shiraz, south Iran. Insects associated with human corpses were carefully collected and put into labelled vials. They were then identified using valid taxonomic keys. Fifteen outdoor (67%) and indoor discovered cadavers were examined. All but one was covered at the time of discovery. From these several species of entomofauna played important roles in the minimum postmortem interval (minPMI) estimate. Insects included the orders of Diptera and Coleoptera. Overall, 14 different species of arthropods were identified. Within Diptera, 2 families of Sarcophagidae and Calliphoridae were present in 73% of the cases with Calliphora vicina Robineau-Desvoidy and Chrysomya albiceps Wiedemann accounting for about half of the cases. The latter family members, Calliphoridae, were more frequently (52%) collected in autumn and winter. Only 4/15 outdoor cadavers had beetles. Four species of Coleopterans; namely Dermestes frischii Kugelann, Nitidula flavomaculata Rossi, Creophilus maxillosus Linnaeus and Saprinus chalcites Illiger; were recorded for the first time from 3 corpses in Iran. The presence and diversity of different insects on human corpses could contribute to the advancement of forensic entomology knowledge and the refined estimates of minPMI in medicolegal cases. Copyright © 2017. Published by Elsevier Ltd.

  12. Desiccation and cold storage of Galleria mellonella cadavers and effects on in vivo production of Steinernema carpocapsae

    NARCIS (Netherlands)

    Wang, X.; Wang, H.; Feng, Q.Z.; Cui, X.Y.; Liu, R.Y.; Sun, Y.B.; Li, G.C.; Tan, H.; Song, D.M.; Liu, W.; Ruan, W.B.; Harvey, J.A.

    2014-01-01

    BACKGROUNDDirect application of insect cadavers infected with entomopathogenic nematodes (EPN) can successfully control target pest insects. Little is known about the effects of environmental factors (desiccation and temperature) on the production process for infective juveniles (IJ) in insects.

  13. Shoulder Arthroscopy Simulator Training Improves Shoulder Arthroscopy Performance in a Cadaver Model

    Science.gov (United States)

    Henn, R. Frank; Shah, Neel; Warner, Jon J.P.; Gomoll, Andreas H.

    2013-01-01

    Purpose The purpose of this study was to quantify the benefits of shoulder arthroscopy simulator training with a cadaver model of shoulder arthroscopy. Methods Seventeen first year medical students with no prior experience in shoulder arthroscopy were enrolled and completed this study. Each subject completed a baseline proctored arthroscopy on a cadaveric shoulder, which included controlling the camera and completing a standard series of tasks using the probe. The subjects were randomized, and nine of the subjects received training on a virtual reality simulator for shoulder arthroscopy. All subjects then repeated the same cadaveric arthroscopy. The arthroscopic videos were analyzed in a blinded fashion for time to task completion and subjective assessment of technical performance. The two groups were compared with students t-tests, and change over time within groups was analyzed with paired t-tests. Results There were no observed differences between the two groups on the baseline evaluation. The simulator group improved significantly from baseline with respect to time to completion and subjective performance (parthroscopy simulator training resulted in significant benefits in clinical shoulder arthroscopy time to task completion in this cadaver model. This study provides important additional evidence of the benefit of simulators in orthopaedic surgical training. Clinical Relevance There may be a role for simulator training in shoulder arthroscopy education. PMID:23591380

  14. Desiccation and cold storage of Galleria mellonella cadavers and effects on in vivo production of Steinernema carpocapsae

    NARCIS (Netherlands)

    Wang, Xin; Wang, Huan; Feng, Qing-zhou; Cui, Xi-yang; Liu, Ri-yue; Sun, Yan-bo; Li, Guo-chao; Tan, Hao; Song, Dong-min; Liu, Wen; Ruan, Wei-bin; Harvey, J.A.

    2014-01-01

    BACKGROUND: Direct application of insect cadavers infected with entomopathogenic nematodes (EPN) can successfully control target pest insects. Little is known about the effects of environmental factors (desiccation and temperature) on the production process for infective juveniles (IJ) in insects.

  15. Comparison of 2 canal preparation techniques in the induction of microcracks: a pilot study with cadaver mandibles.

    Science.gov (United States)

    Arias, Ana; Lee, Yoon H; Peters, Christine I; Gluskin, Alan H; Peters, Ove A

    2014-07-01

    The purpose of this pilot study in a cadaver model was to compare 2 different shaping techniques regarding the induction of dentinal microcracks. Three lower incisors from each of 6 adult human cadaver skulls were randomly distributed into 3 groups: the control group (CG, no instrumentation), the GT group (GT Profile hand files; Dentsply Tulsa Dental, Tulsa, OK), and the WO group (WaveOne; Dentsply Tulsa Dental). In the GT group, manual shaping in a crown-down sequence with GT Profile hand files was performed. In the WO group, Primary WaveOne files were used to the working length. Teeth were separated from the mandibles by careful removal of soft tissue and bone under magnification. Roots were sectioned horizontally at 3, 6, and 9 mm from the apex using a low-speed saw. Color photographs at 2 magnifications (25× and 40×) were obtained. Three blinded examiners registered the presence of microcracks (yes/no), extension (incomplete/complete), direction (buccolingual/mesiodistal), and location. Data were analyzed with chi-square tests at P < .05. Microcracks were found in 50% (CG and GT) and 66% (WO) of teeth at 3 mm, 16.6% (CG) and 33.3% (GT and WO) at 6 mm, and 16.6% in all 3 groups at 9 mm from the apex. There were no significant differences in the incidence of microcracks between all groups at 3 (P = .8), 6 (P = .8), or 9 mm (P = 1). All microcracks were incomplete, started at the pulpal wall, and had a buccolingual direction. Within the limitations of this pilot study, a relationship between the shaping techniques (GT hand and WaveOne) and the incidence of microcracks could not be shown compared with uninstrumented controls. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Three-Dimensional Changes in the Midface Following Malar Calcium Hydroxyapatite Injection in a Cadaver Model.

    Science.gov (United States)

    Gatherwright, James R; Brown, Matthew S; Katira, Kristopher M; Rowe, David J

    2015-08-01

    Three-dimensional (3D) changes in the midface following malar calcium hydroxyapatite (CaHa) injection have not been systematically analyzed. The authors analyzed 3D volume changes in midface and naso-labial fold (NLF) volume, as well as lateral movement in the NLF/naso-labial crease (NLC) junction following malar injection of CaHa in a cadaver model. A single surgeon injected CaHa in the supraperiosteal plane. Sequential images were obtained with the VECTRA 3D system pre- and post-1.5- and 3-cc CaHa injections. All measurements were performed by a single examiner. Injection location was verified anatomically. Injections were performed in 16 fresh cadaver hemi-faces. Maximal increases in projection were centered on the malar injection site, with associated decreases in projection and volume in the infero-medial locations. Relative mean increases in volume of 3.16 cc and 4.94 cc were observed following the 1.5-cc and 3-cc injections, respectively. There was a relative decrease in the volume of the NLF of -0.3 cc and -0.4 cc following the 1.5- and 3-cc injections, respectively. Injection of CaHa was associated with lateral movements of the NLF-NLC junction at the level of the nasal sill, philtral columns, and oral commissure, measuring 2.7, 2.5, and 1.9 mm and 2.8, 2.9, and 2.4 mm following the 1.5- and 3-cc injections, respectively. Anatomical dissection verified the location in the supraperiosteal space and within the middle malar fat pad. Following malar CaHa injection, 3D photographic analysis showed a measureable lifting effect with recruitment of ptotic tissue and lateral movement of the NLF-NLC junction in a cadaver model. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  17. Foot-controlled robotic-enabled endoscope holder for endoscopic sinus surgery: A cadaveric feasibility study.

    Science.gov (United States)

    Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F

    2016-03-01

    To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  18. Head Start Impact Study

    Data.gov (United States)

    U.S. Department of Health & Human Services — Nationally representative, longitudinal information from an evaluation where children were randomly assigned to Head Start or community services as usual;direct...

  19. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  20. Sex Hormone Receptor Expression in the Human Vocal Fold Subunits.

    Science.gov (United States)

    Kirgezen, Tolga; Sunter, Ahmet Volkan; Yigit, Ozgur; Huq, Gulben Erdem

    2017-07-01

    The study aimed to evaluate the existence of sex hormone receptors in the subunits of vocal fold. This is a cadaver study. The androgen, estrogen, and progesterone receptors were examined in the epithelium (EP), superficial layer of the lamina propria (SLP), vocal ligament (VL), and macula flava (MF) of the vocal folds from 42 human cadavers (21 male, 21 female) by immunohistochemical methods. Their staining ratios were scored and statistically compared. The androgen receptor score was significantly higher for the MF than for the EP and SLP (P vocal fold, mostly in the MF and VLs. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  1. Early Head Start Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — Longitudinal information from an evaluation where children were randomly assigned to Early Head Start or community services as usual;direct assessments and...

  2. Stretching positions for the coracohumeral ligament: Strain measurement during passive motion using fresh/frozen cadaver shoulders

    Directory of Open Access Journals (Sweden)

    Izumi Tomoki

    2011-01-01

    Full Text Available Abstract Background Contracture of the coracohumeral ligament is reported to restrict external rotation of the shoulder with arm at the side and restrict posterior-inferior shift of the humeral head. The contracture is supposed to restrict range of motion of the glenohumeral joint. Methods To obtain stretching position of the coracohumeral ligament, strain on the ligament was measured at the superficial fibers of the ligament using 9 fresh/frozen cadaver shoulders. By sequential measurement using a strain gauge, the ligament strain was measured from reference length (L0. Shoulder positions were determined using a 3 Space Tracker System. Through a combination of previously reported coracohumeral stretching positions and those observed in preliminary measurement, ligament strain were measured by passive external rotation from 10° internal rotation, by adding each 10° external rotation, to maximal external rotation. Results Stretching positions in which significantly larger strain were obtained compared to the L0 values were 0° elevation in scapula plane with 40°, 50° and maximum external rotation (5.68%, 7.2%, 7.87%, 30° extension with 50°, maximum external rotation (4.20%, 4.79%, and 30° extension + adduction with 30°, 40°, 50° and maximum external rotation (4.09%, 4.67%, 4.78%, 5.05%(P Conclusions Significant strain of the coracohumeral ligament will be achieved by passive external rotation at lower shoulder elevations, extension, and extension with adduction.

  3. Cadaver-specific CT scans visualized at the dissection table combined with virtual dissection tables improve learning performance in general gross anatomy.

    Science.gov (United States)

    Paech, Daniel; Giesel, Frederik L; Unterhinninghofen, Roland; Schlemmer, Heinz-Peter; Kuner, Thomas; Doll, Sara

    2017-05-01

    The purpose of this study was to quantify the benefit of the incorporation of radiologic anatomy (RA), in terms of student training in RA seminars, cadaver CT scans and life-size virtual dissection tables on the learning success in general anatomy. Three groups of a total of 238 students were compared in a multiple choice general anatomy exam during first-year gross anatomy: (1) a group (year 2015, n 1  = 50) that received training in radiologic image interpretation (RA seminar) and additional access to cadaver CT scans (CT + seminar group); (2) a group (2011, n 2  = 90) that was trained in the RA seminar only (RA seminar group); (3) a group (2011, n 3  = 98) without any radiologic image interpretation training (conventional anatomy group). Furthermore, the students' perception of the new curriculum was assessed qualitatively through a survey. The average test score of the CT + seminar group (21.8 ± 5.0) was significantly higher when compared to both the RA seminar group (18.3 ± 5.0) and the conventional anatomy group (17.1 ± 4.7) (p cadaver CT scans and life-size virtual dissection tables significantly improved the performance of medical students in general gross anatomy. Medical imaging and virtual dissection should therefore be considered to be part of the standard curriculum of gross anatomy. • Students provided with cadaver CT scans achieved 27 % higher scores in anatomy. • Radiological education integrated into gross anatomy is highly appreciated by medical students. • Simultaneous physical and virtual dissection provide unique conditions to study anatomy.

  4. Heading-vector navigation based on head-direction cells and path integration.

    Science.gov (United States)

    Kubie, John L; Fenton, André A

    2009-05-01

    , heading-based navigation is used in small mammals and humans. Copyright 2008 Wiley-Liss, Inc.

  5. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Directory of Open Access Journals (Sweden)

    Camille Chesnel

    Full Text Available Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia.To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers.Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred.Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%: 4 (1% in tendons or muscles, 3 (0.7% in nerves and 1 (0.2% in a vessel.This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  6. Effectiveness and Complications of Percutaneous Needle Tenotomy with a Large Needle for Muscle Contractures: A Cadaver Study.

    Science.gov (United States)

    Chesnel, Camille; Genêt, François; Almangour, Waleed; Denormandie, Philippe; Parratte, Bernard; Schnitzler, Alexis

    2015-01-01

    Twenty-two percent of institutionalised elderly persons have muscle contractures. Contractures have important functional consequences, rendering hygiene and positioning in bed or in a chair difficult. Medical treatment (such as botulinum toxin injections, physiotherapy or positioning) is not very effective and surgery may be required. Surgery is carried out in the operating theatre, under local or general anaesthesia but is often not possible in fragile patients. Mini-invasive tenotomy could be a useful alternative as it can be carried out in ambulatory care, under local anaesthesia. To evaluate the effectiveness of percutaneous needle tenotomy and the risks of damage to adjacent structures in cadavers. Thirty two doctors who had never practiced the technique (physical medicine and rehabilitation specialists, geriatricians and orthopaedic surgeons) carried out 401 tenotomies on the upper and lower limbs of 8 fresh cadavers. A 16G needle was used percutaneous following location of the tendons. After each tenotomy, a neuro-orthopaedic surgeon and an anatomist dissected the area in order to evaluate the success of the tenotomy and any adjacent lesions which had occurred. Of the 401 tenotomies, 72% were complete, 24.9% partial and 2.7% failed. Eight adjacent lesions occurred (2%): 4 (1%) in tendons or muscles, 3 (0.7%) in nerves and 1 (0.2%) in a vessel. This percutaneous needle technique effectively ruptured the desired tendons, with few injuries to adjacent structures. Although this study was carried out on cadavers, the results suggest it is safe to carry out on patients.

  7. Human Papillomavirus Genome Integration and Head and Neck Cancer.

    Science.gov (United States)

    Pinatti, L M; Walline, H M; Carey, T E

    2018-06-01

    We conducted a critical review of human papillomavirus (HPV) integration into the host genome in oral/oropharyngeal cancer, reviewed the literature for HPV-induced cancers, and obtained current data for HPV-related oral and oropharyngeal cancers. In addition, we performed studies to identify HPV integration sites and the relationship of integration to viral-host fusion transcripts and whether integration is required for HPV-associated oncogenesis. Viral integration of HPV into the host genome is not required for the viral life cycle and might not be necessary for cellular transformation, yet HPV integration is frequently reported in cervical and head and neck cancer specimens. Studies of large numbers of early cervical lesions revealed frequent viral integration into gene-poor regions of the host genome with comparatively rare integration into cellular genes, suggesting that integration is a stochastic event and that site of integration may be largely a function of chance. However, more recent studies of head and neck squamous cell carcinomas (HNSCCs) suggest that integration may represent an additional oncogenic mechanism through direct effects on cancer-related gene expression and generation of hybrid viral-host fusion transcripts. In HNSCC cell lines as well as primary tumors, integration into cancer-related genes leading to gene disruption has been reported. The studies have shown that integration-induced altered gene expression may be associated with tumor recurrence. Evidence from several studies indicates that viral integration into genic regions is accompanied by local amplification, increased expression in some cases, interruption of gene expression, and likely additional oncogenic effects. Similarly, reported examples of viral integration near microRNAs suggest that altered expression of these regulatory molecules may also contribute to oncogenesis. Future work is indicated to identify the mechanisms of these events on cancer cell behavior.

  8. Interosseous Ligament and Transverse Forearm Stability: A Biomechanical Cadaver Study.

    Science.gov (United States)

    Gutowski, Christina J; Darvish, Kurosh; Ilyas, Asif M; Jones, Christopher M

    2017-02-01

    The interosseous ligament (IOL) is known to be an important longitudinal stabilizer of the forearm. We hypothesize that it may also contribute to transverse stability, with pronosupination tensioning of the radius relative to the ulna. Therefore, when injured, we predict the interosseous space should widen in the transverse plane, enough to be appreciable on plain radiographs. A measurable difference in interosseous space, comparing an injured with an uninjured forearm, can potentially be of diagnostic and clinical value. Ten fresh-frozen cadaver arms (from 5 individuals) were radiographed in 6 different positions of forearm supination, first in an uninjured state and then with the IOL sectioned, both partially (central band only) and completely. The transverse interosseous distance was measured on radiographs using edge detection software and compared using analysis of variance and contrast analysis. The maximum range of pronosupination was also compared before and after injury, using a paired t test. Average maximum supination increased from 84° to 106°, and pronation from 69° to 84°, after the IOL was sectioned completely. Sectioning of the IOL led to a statistically significant increase in the interosseous distance, a minimum of 2 mm, in all but one forearm position. The IOL of the forearm plays an important role in providing transverse stability to the radius and ulna. When the IOL is sectioned, the forearm exhibits increased pronosupination range of motion. Radiographs of bilateral forearms taken in identical rotational position can reliably differentiate between an intact and torn IOL in cadavers. The IOL's stabilizing role during forearm rotation suggests a novel strategy for diagnosing forearm IOL injury using comparative radiographic measurements. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Pathological study of degenerative changes of finger joints in cadavers of aged persons

    OpenAIRE

    岩田,芳之

    1987-01-01

    In the present study, soft x-ray and light microscopic examinations were carried out on 17 interphalangeal (IP) joints and 85 distal interphalangeal (DIP) joints with Heberden's nodes from 15 cadavers. Microradiograms of the IP and DIP joints were analyzed as to the degenerative changes in the antero-posterior and lateral views according to our own criteria. Degenerative changes were more severe in females than in males. Advanced degeneration was found in the index, middle and little fingers,...

  10. Head Start Impact Study. Technical Report

    Science.gov (United States)

    Puma, Michael; Bell, Stephen; Cook, Ronna; Heid, Camilla; Shapiro, Gary; Broene, Pam; Jenkins, Frank; Fletcher, Philip; Quinn, Liz; Friedman, Janet; Ciarico, Janet; Rohacek, Monica; Adams, Gina; Spier, Elizabeth

    2010-01-01

    This Technical Report is designed to provide technical detail to support the analysis and findings presented in the "Head Start Impact Study Final Report" (U.S. Department of Health and Human Services, January 2010). Chapter 1 provides an overview of the Head Start Impact Study and its findings. Chapter 2 provides technical information on the…

  11. Indoors forensic entomology: colonization of human remains in closed environments by specific species of sarcosaprophagous flies.

    Science.gov (United States)

    Pohjoismäki, Jaakko L O; Karhunen, Pekka J; Goebeler, Sirkka; Saukko, Pekka; Sääksjärvi, Ilari E

    2010-06-15

    Fly species that are commonly recovered on human corpses concealed in houses or other dwellings are often dependent on human created environments and might have special features in their biology that allow them to colonize indoor cadavers. In this study we describe nine typical cases involving forensically relevant flies on human remains found indoors in southern Finland. Eggs, larvae and puparia were reared to adult stage and determined to species. Of the five species found the most common were Lucilia sericata Meigen, Calliphora vicina Robineau-Desvoidy and Protophormia terraenovae Robineau-Desvoidy. The flesh fly Sarcophaga caerulescens Zetterstedt is reported for the first time to colonize human cadavers inside houses and a COI gene sequence based DNA barcode is provided for it to help facilitate identification in the future. Fly biology, colonization speed and the significance of indoors forensic entomological evidence are discussed. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  12. Lessons from dynamic cadaver and invasive bone pin studies: do we know how the foot really moves during gait?

    Directory of Open Access Journals (Sweden)

    Nester Christopher J

    2009-05-01

    Full Text Available Abstract Background This paper provides a summary of a Keynote lecture delivered at the 2009 Australasian Podiatry Conference. The aim of the paper is to review recent research that has adopted dynamic cadaver and invasive kinematics research approaches to better understand foot and ankle kinematics during gait. It is not intended to systematically cover all literature related to foot and ankle kinematics (such as research using surface mounted markers. Since the paper is based on a keynote presentation its focuses on the authors own experiences and work in the main, drawing on the work of others where appropriate Methods Two approaches to the problem of accessing and measuring the kinematics of individual anatomical structures in the foot have been taken, (i static and dynamic cadaver models, and (ii invasive in-vivo research. Cadaver models offer the advantage that there is complete access to all the tissues of the foot, but the cadaver must be manipulated and loaded in a manner which replicates how the foot would have performed when in-vivo. The key value of invasive in-vivo foot kinematics research is the validity of the description of foot kinematics, but the key difficulty is how generalisable this data is to the wider population. Results Through these techniques a great deal has been learnt. We better understand the valuable contribution mid and forefoot joints make to foot biomechanics, and how the ankle and subtalar joints can have almost comparable roles. Variation between people in foot kinematics is high and normal. This includes variation in how specific joints move and how combinations of joints move. The foot continues to demonstrate its flexibility in enabling us to get from A to B via a large number of different kinematic solutions. Conclusion Rather than continue to apply a poorly founded model of foot type whose basis is to make all feet meet criteria for the mechanical 'ideal' or 'normal' foot, we should embrace variation

  13. A Technique to Perfuse Cadavers that Extends the Useful Life of Fresh Tissues: The Duke Experience

    Science.gov (United States)

    Messmer, Caroline; Kellogg, Ryan T.; Zhang, Yixin; Baiak, Andresa; Leiweke, Clinton; Marcus, Jeffrey R.; Levin, L. Scott; Zenn, Michael R.; Erdmann, Detlev

    2010-01-01

    The demand for laboratory-based teaching and training is increasing worldwide as medical training and education confront the pressures of shorter training time and rising costs. This article presents a cost-effective perfusion technique that extends the useful life of fresh tissue. Refrigerated cadavers are preserved in their natural state for up…

  14. Statistical analysis of biomechanical properties of the adult skull and age-related structural changes by sex in a Japanese forensic sample.

    Science.gov (United States)

    Torimitsu, Suguru; Nishida, Yoshifumi; Takano, Tachio; Koizumi, Yoshinori; Makino, Yohsuke; Yajima, Daisuke; Hayakawa, Mutsumi; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Otsuka, Katsura; Kobayashi, Kazuhiro; Odo, Yuriko; Iwase, Hirotaro

    2014-01-01

    The purpose of this research was to investigate the biomechanical properties of the adult human skull and the structural changes that occur with age in both sexes. The heads of 94 Japanese cadavers (54 male cadavers, 40 female cadavers) autopsied in our department were used in this research. A total of 376 cranial samples, four from each skull, were collected. Sample fracture load was measured by a bending test. A statistically significant negative correlation between the sample fracture load and cadaver age was found. This indicates that the stiffness of cranial bones in Japanese individuals decreases with age, and the risk of skull fracture thus probably increases with age. Prior to the bending test, the sample mass, the sample thickness, the ratio of the sample thickness to cadaver stature (ST/CS), and the sample density were measured and calculated. Significant negative correlations between cadaver age and sample thickness, ST/CS, and the sample density were observed only among the female samples. Computerized tomographic (CT) images of 358 cranial samples were available. The computed tomography value (CT value) of cancellous bone which refers to a quantitative scale for describing radiodensity, cancellous bone thickness and cortical bone thickness were measured and calculated. Significant negative correlation between cadaver age and the CT value or cortical bone thickness was observed only among the female samples. These findings suggest that the skull is substantially affected by decreased bone metabolism resulting from osteoporosis. Therefore, osteoporosis prevention and treatment may increase cranial stiffness and reinforce the skull structure, leading to a decrease in the risk of skull fractures. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Modelling and assessment of the electric field strength caused by mobile phone to the human head.

    Science.gov (United States)

    Buckus, Raimondas; Strukcinskiene, Birute; Raistenskis, Juozas; Stukas, Rimantas

    2016-06-01

    Electromagnetic field exposure is the one of the most important physical agents that actively affects live organisms and environment. Active use of mobile phones influences the increase of electromagnetic field radiation. The aim of the study was to measure and assess the electric field strength caused by mobile phones to the human head. In this paper the software "COMSOL Multiphysics" was used to establish the electric field strength created by mobile phones around the head. The second generation (2G) Global System for Mobile (GSM) phones that operate in the frequency band of 900 MHz and reach the power of 2 W have a stronger electric field than (2G) GSM mobile phones that operate in the higher frequency band of 1,800 MHz and reach the power up to 1 W during conversation. The third generation of (3G) UMTS smart phones that effectively use high (2,100 MHz) radio frequency band emit the smallest electric field strength values during conversation. The highest electric field strength created by mobile phones is around the ear, i.e. the mobile phone location. The strength of mobile phone electric field on the phantom head decreases exponentially while moving sidewards from the center of the effect zone (the ear), and constitutes 1-12% of the artificial head's surface. The highest electric field strength values of mobile phones are associated with their higher power, bigger specific energy absorption rate (SAR) and lower frequency of mobile phone. The stronger electric field emitted by the more powerful mobile phones takes a higher percentage of the head surface. The highest electric field strength created by mobile phones is distributed over the user's ear.

  16. Computer Modeling and Simulation of Bullet Impact to the Human Thorax

    National Research Council Canada - National Science Library

    Jolly, Johannes

    2000-01-01

    .... The objective of the study was to create a viable finite element model of the human thorax. The model was validated by comparing the results of tests of body armor systems conducted on cadavers to results obtained from finite element analysis...

  17. The development, assessment and validation of virtual reality for human anatomy instruction

    Science.gov (United States)

    Marshall, Karen Benn

    1996-01-01

    This research project seeks to meet the objective of science training by developing, assessing, validating and utilizing VR as a human anatomy training medium. Current anatomy instruction is primarily in the form of lectures and usage of textbooks. In ideal situations, anatomic models, computer-based instruction, and cadaver dissection are utilized to augment traditional methods of instruction. At many institutions, lack of financial resources limits anatomy instruction to textbooks and lectures. However, human anatomy is three-dimensional, unlike the one-dimensional depiction found in textbooks and the two-dimensional depiction found on the computer. Virtual reality allows one to step through the computer screen into a 3-D artificial world. The primary objective of this project is to produce a virtual reality application of the abdominopelvic region of a human cadaver that can be taken back to the classroom. The hypothesis is that an immersive learning environment affords quicker anatomic recognition and orientation and a greater level of retention in human anatomy instruction. The goal is to augment not replace traditional modes of instruction.

  18. Modeling the Biodynamical Response of the Human Thorax with Body Armor from a Bullet Impact

    National Research Council Canada - National Science Library

    Lobuono, John

    2001-01-01

    .... The finite element model of the human thorax is validated by comparing the model's results to experimental data obtained from cadavers wearing a protective body armor system undergoing a projectile impact...

  19. Modeling the Biodynamical Response of the Human Thorax With Body Armor From a Bullet Impact

    National Research Council Canada - National Science Library

    Lobuono, John

    2001-01-01

    .... The finite element model of the human thorax is validated by comparing the model's results to experimental data obtained from cadavers wearing a protective body armor system undergoing a projectile impact...

  20. Three Software Tools for Viewing Sectional Planes, Volume Models, and Surface Models of a Cadaver Hand.

    Science.gov (United States)

    Chung, Beom Sun; Chung, Min Suk; Shin, Byeong Seok; Kwon, Koojoo

    2018-02-19

    The hand anatomy, including the complicated hand muscles, can be grasped by using computer-assisted learning tools with high quality two-dimensional images and three-dimensional models. The purpose of this study was to present up-to-date software tools that promote learning of stereoscopic morphology of the hand. On the basis of horizontal sectioned images and outlined images of a male cadaver, vertical planes, volume models, and surface models were elaborated. Software to browse pairs of the sectioned and outlined images in orthogonal planes and software to peel and rotate the volume models, as well as a portable document format (PDF) file to select and rotate the surface models, were produced. All of the software tools were downloadable free of charge and usable off-line. The three types of tools for viewing multiple aspects of the hand could be adequately employed according to individual needs. These new tools involving the realistic images of a cadaver and the diverse functions are expected to improve comprehensive knowledge of the hand shape. © 2018 The Korean Academy of Medical Sciences.

  1. Too fresh is unattractive! The attraction of newly emerged Nicrophorus vespilloides females to odour bouquets of large cadavers at various stages of decomposition.

    Directory of Open Access Journals (Sweden)

    Christian von Hoermann

    Full Text Available The necrophagous burying beetle Nicrophorus vespilloides reproduces on small carcasses that are buried underground to serve as food for their offspring. Cadavers that are too large to bury have previously been postulated to be important food sources for newly emerged beetles; however, the attractiveness of distinct successive stages of decomposition were not further specified. Therefore, we investigated the potential preference of newly emerged N. vespilloides females for odour bouquets of piglet cadavers at specific stages of decomposition. Analyses of walking tracks on a Kramer sphere revealed a significantly higher mean walking speed and, consequently, a higher mean total track length when beetles were confronted with odour plumes of the decomposition stages 'post-bloating', 'advanced decay' or 'dry remains' in comparison with the solvent control. Such a change of the walking speed of newly emerged N. vespilloides females indicates a higher motivation to locate such food sources. In contrast to less discriminating individuals this behaviour provides the advantage of not wasting time at unsuitable food sources. Furthermore, in the advanced decay stage, we registered a significantly higher preference of beetles for upwind directions to its specific odour plume when compared with the solvent control. Such a change to upwind walking behaviour increases the likelihood that a large cadaver will be quickly located. Our findings are of general importance for applied forensic entomology: newly emerged N. vespilloides females on large cadavers can and should be regarded as potential indicators of prolonged post mortem intervals as our results clearly show that they prefer emitted odour bouquets of later decomposition stages.

  2. Highly preserved consensus gene modules in human papilloma virus 16 positive cervical cancer and head and neck cancers.

    Science.gov (United States)

    Zhang, Xianglan; Cha, In-Ho; Kim, Ki-Yeol

    2017-12-26

    In this study, we investigated the consensus gene modules in head and neck cancer (HNC) and cervical cancer (CC). We used a publicly available gene expression dataset, GSE6791, which included 42 HNC, 14 normal head and neck, 20 CC and 8 normal cervical tissue samples. To exclude bias because of different human papilloma virus (HPV) types, we analyzed HPV16-positive samples only. We identified 3824 genes common to HNC and CC samples. Among these, 977 genes showed high connectivity and were used to construct consensus modules. We demonstrated eight consensus gene modules for HNC and CC using the dissimilarity measure and average linkage hierarchical clustering methods. These consensus modules included genes with significant biological functions, including ATP binding and extracellular exosome. Eigengen network analysis revealed the consensus modules were highly preserved with high connectivity. These findings demonstrate that HPV16-positive head and neck and cervical cancers share highly preserved consensus gene modules with common potentially therapeutic targets.

  3. A three dimensional children head database for acoustical research and development

    DEFF Research Database (Denmark)

    Harder, Stine; Paulsen, Rasmus Reinhold; Larsen, Martin

    2013-01-01

    Most computational-acoustic work within spatial hearing relies on head-related transfer functions from databases of measurements taken on adult humans or dummy heads. We aim to provide a set of 3D digital heads including children, from which head-related transfer functions can be computed instead...

  4. Tridimensional pose estimation of a person head

    International Nuclear Information System (INIS)

    Perez Berenguer, Elisa; Soria, Carlos; Nasisi, Oscar; Mut, Vicente

    2007-01-01

    In this work, we present a method for estimating 3-D motion parameters; this method provides an alternative way for 3D head pose estimation from image sequence in the current computer vision literature. This method is robust over extended sequences and large head motions and accurately extracts the orientation angles of head from a single view. Experimental results show that this tracking system works well for development a human-computer interface for people that possess severe motor incapacity

  5. Preliminarily measurement and analysis of sawing forces in fresh cadaver mandible using reciprocating saw for reality-based haptic feedback.

    Science.gov (United States)

    Yua, Dedong; Zhengb, Xiaohu; Chenc, Ming; Shend, Steve G F

    2012-05-01

    The aim of the study was to preliminarily measure and analyze the cutting forces in fresh Chinese cadaver mandible using a clinically widely used reciprocating saw for reality-based haptic feedback. Eight mandibles were taken from fresh Chinese cadavers, 4 females and 4 males, aged between 59 and 95 years. A set of sawing experiments, using a surgery Stryker micro-reciprocating saw and Kistler piezoelectric dynamometer, was carried out by a CNC machining center. Under different vibration frequencies of saw and feeding rates measured from orthognathic surgery, sawing forces were recorded by a signal acquisition system. Remarkably different sawing forces were measured from different cadavers. Feed and vibration frequency of the reciprocating saw could determine the cutting forces only on 1 body. To reduce the impact of bone thickness changes on the cutting force measurements, all the cutting force data should be converted to the force of unit cutting length. The vibration frequency of haptic feedback system is determined by main cutting forces. Fast Fourier transform method can be used to calculate the frequency of this system. To simulate surgery in higher fidelity, all the sawing forces from the experiment should be amended by experienced surgeons before use in virtual reality surgery simulator. Sawing force signals of different ages for force feedback were measured successfully, and more factors related to the bone mechanical properties, such as bone density, should be concerned in the future.

  6. A unified model of heading and path perception in primate MSTd.

    Directory of Open Access Journals (Sweden)

    Oliver W Layton

    2014-02-01

    Full Text Available Self-motion, steering, and obstacle avoidance during navigation in the real world require humans to travel along curved paths. Many perceptual models have been proposed that focus on heading, which specifies the direction of travel along straight paths, but not on path curvature, which humans accurately perceive and is critical to everyday locomotion. In primates, including humans, dorsal medial superior temporal area (MSTd has been implicated in heading perception. However, the majority of MSTd neurons respond optimally to spiral patterns, rather than to the radial expansion patterns associated with heading. No existing theory of curved path perception explains the neural mechanisms by which humans accurately assess path and no functional role for spiral-tuned cells has yet been proposed. Here we present a computational model that demonstrates how the continuum of observed cells (radial to circular in MSTd can simultaneously code curvature and heading across the neural population. Curvature is encoded through the spirality of the most active cell, and heading is encoded through the visuotopic location of the center of the most active cell's receptive field. Model curvature and heading errors fit those made by humans. Our model challenges the view that the function of MSTd is heading estimation, based on our analysis we claim that it is primarily concerned with trajectory estimation and the simultaneous representation of both curvature and heading. In our model, temporal dynamics afford time-history in the neural representation of optic flow, which may modulate its structure. This has far-reaching implications for the interpretation of studies that assume that optic flow is, and should be, represented as an instantaneous vector field. Our results suggest that spiral motion patterns that emerge in spatio-temporal optic flow are essential for guiding self-motion along complex trajectories, and that cells in MSTd are specifically tuned to extract

  7. A Unified Model of Heading and Path Perception in Primate MSTd

    Science.gov (United States)

    Layton, Oliver W.; Browning, N. Andrew

    2014-01-01

    Self-motion, steering, and obstacle avoidance during navigation in the real world require humans to travel along curved paths. Many perceptual models have been proposed that focus on heading, which specifies the direction of travel along straight paths, but not on path curvature, which humans accurately perceive and is critical to everyday locomotion. In primates, including humans, dorsal medial superior temporal area (MSTd) has been implicated in heading perception. However, the majority of MSTd neurons respond optimally to spiral patterns, rather than to the radial expansion patterns associated with heading. No existing theory of curved path perception explains the neural mechanisms by which humans accurately assess path and no functional role for spiral-tuned cells has yet been proposed. Here we present a computational model that demonstrates how the continuum of observed cells (radial to circular) in MSTd can simultaneously code curvature and heading across the neural population. Curvature is encoded through the spirality of the most active cell, and heading is encoded through the visuotopic location of the center of the most active cell's receptive field. Model curvature and heading errors fit those made by humans. Our model challenges the view that the function of MSTd is heading estimation, based on our analysis we claim that it is primarily concerned with trajectory estimation and the simultaneous representation of both curvature and heading. In our model, temporal dynamics afford time-history in the neural representation of optic flow, which may modulate its structure. This has far-reaching implications for the interpretation of studies that assume that optic flow is, and should be, represented as an instantaneous vector field. Our results suggest that spiral motion patterns that emerge in spatio-temporal optic flow are essential for guiding self-motion along complex trajectories, and that cells in MSTd are specifically tuned to extract complex trajectory

  8. Examining High School Anatomy and Physiology Teacher Experience in a Cadaver Dissection Laboratory and Impacts on Practice

    Science.gov (United States)

    Mattheis, Allison; Ingram, Debra; Jensen, Murray S.; Jackson, Jon

    2015-01-01

    This article describes the results of a study that investigated the experiences of a group of high school anatomy and physiology teachers who participated in a cadaver dissection laboratory workshop organized through a university-school partnership. Teacher feedback was collected before, during, and after the workshop through pre-arrival surveys,…

  9. Influência do ligamento da cabeça do fêmur na mecânica do quadril Influence of the femoral head ligament on hip mechanical function

    Directory of Open Access Journals (Sweden)

    Marco Kawamura Demange

    2007-01-01

    Full Text Available Investigamos a influência do ligamento da cabeça do fêmur no arco de movimento de flexão-extensão e de adução-abdução do quadril. Para isso foram realizadas medidas em 7 quadris de cadáveres humanos, inicialmente com os ligamentos íntegros; posteriormente com a artroscopia e a seguir com os ligamentos seccionados também através de técnica artroscópica. Foi utilizado para isso um dispositivo elaborado para se medir o arco de movimento submetido a um torque de 2,5 N.m . Foi observado aumento com significância estatística no arco de abdução-adução às custas de adução. Concluímos que o ligamento da cabeça do fêmur influi limitando a adução do quadril.The authors investigated the femoral head ligament at hip flexion-extension and adduction-abduction ranges of motion. Seven human cadavers' hips were measured, initially with intact ligaments, and, subsequently, through arthroscopy, and then with sectioned ligaments also by means of arthroscopy. A specifically prepared device was used for measuring the range of motion which was submitted to a 2.5 N.m torque. An increased abduction-adduction range of motion was observed, which was statistically significant. We concluded that the femoral head ligament restricts hip adduction.

  10. Thermal effects of whole head submersion in cold water on nonshivering humans.

    Science.gov (United States)

    Pretorius, Thea; Bristow, Gerald K; Steinman, Alan M; Giesbrecht, Gordon G

    2006-08-01

    This study isolated the effect of whole head submersion in cold water, on surface heat loss and body core cooling, when the confounding effect of shivering heat production was pharmacologically eliminated. Eight healthy male subjects were studied in 17 degrees C water under four conditions: the body was either insulated or uninsulated, with the head either above the water or completely submersed in each body-insulation subcondition. Shivering was abolished with buspirone (30 mg) and meperidine (2.5 mg/kg), and subjects breathed compressed air throughout all trials. Over the first 30 min of immersion, exposure of the head increased core cooling both in the body-insulated conditions (head out: 0.47 +/- 0.2 degrees C, head in: 0.77 +/- 0.2 degrees C; P body-exposed conditions (head out: 0.84 +/- 0.2 degrees C and head in: 1.17 +/- 0.5 degrees C; P body surface area) in the body-exposed conditions increased total heat loss by only 10%. In both body-exposed and body-insulated conditions, head submersion increased core cooling rate much more (average of 42%) than it increased total heat loss. This may be explained by a redistribution of blood flow in response to stimulation of thermosensitive and/or trigeminal receptors in the scalp, neck and face, where a given amount of heat loss would have a greater cooling effect on a smaller perfused body mass. In 17 degrees C water, the head does not contribute relatively more than the rest of the body to surface heat loss; however, a cold-induced reduction of perfused body mass may allow this small increase in heat loss to cause a relatively larger cooling of the body core.

  11. Simplified realistic human head model for simulating Tumor Treating Fields (TTFields).

    Science.gov (United States)

    Wenger, Cornelia; Bomzon, Ze'ev; Salvador, Ricardo; Basser, Peter J; Miranda, Pedro C

    2016-08-01

    Tumor Treating Fields (TTFields) are alternating electric fields in the intermediate frequency range (100-300 kHz) of low-intensity (1-3 V/cm). TTFields are an anti-mitotic treatment against solid tumors, which are approved for Glioblastoma Multiforme (GBM) patients. These electric fields are induced non-invasively by transducer arrays placed directly on the patient's scalp. Cell culture experiments showed that treatment efficacy is dependent on the induced field intensity. In clinical practice, a software called NovoTalTM uses head measurements to estimate the optimal array placement to maximize the electric field delivery to the tumor. Computational studies predict an increase in the tumor's electric field strength when adapting transducer arrays to its location. Ideally, a personalized head model could be created for each patient, to calculate the electric field distribution for the specific situation. Thus, the optimal transducer layout could be inferred from field calculation rather than distance measurements. Nonetheless, creating realistic head models of patients is time-consuming and often needs user interaction, because automated image segmentation is prone to failure. This study presents a first approach to creating simplified head models consisting of convex hulls of the tissue layers. The model is able to account for anisotropic conductivity in the cortical tissues by using a tensor representation estimated from Diffusion Tensor Imaging. The induced electric field distribution is compared in the simplified and realistic head models. The average field intensities in the brain and tumor are generally slightly higher in the realistic head model, with a maximal ratio of 114% for a simplified model with reasonable layer thicknesses. Thus, the present pipeline is a fast and efficient means towards personalized head models with less complexity involved in characterizing tissue interfaces, while enabling accurate predictions of electric field distribution.

  12. Effects of cooling portions of the head on human thermoregulatory response.

    Science.gov (United States)

    Katsuura, T; Tomioka, K; Harada, H; Iwanaga, K; Kikuchi, Y

    1996-03-01

    Seven healthy young male students participated in this study. Each subject sat on a chair in an anteroom at 25 degrees C for 30 min and then entered a climatic chamber, controlled at 40 degrees C and R.H. 50%, and sat on a chair for 90 min. Cooling of frontal portion including the region around the eyes (FC), occipital portion (OC), and temporal portion (TC) began after 50 min of entering. An experiment without head cooling (NC) was also made for the control measurement. Thermal comfort and thermal sensation were improved by head cooling, but response was the same regardless of portion cooled. Although rectal temperature, mean skin temperature and heart rate showed no significant effect due to head cooling, forearm skin blood flow (FBF), sweat rate (SR), and body weight loss (delta Wt) had a tendency to be depressed. FBF in FC and TC decreased during head cooling, but that in OC and NC did not change significantly, while SR in FC was depressed. delta Wt showed total sweating to decrease by FC and TC, and FC to have greater inhibitory effect on sweating than OC. Thermal strain was evaluated by the modified Craig Index (I(s)). I(s) in FC decreased significantly more than in NC. Cooling of other portions of the head had no significant effect on I(s). Cooling of the frontal portion of the head may thus be concluded to have the most effect on thermoregulatory response in a hot environment.

  13. Stiffness of the ligaments of the human wrist joint

    NARCIS (Netherlands)

    Savelberg, H.H.C.M.; Kooloos, J.G.M.; Huiskes, H.W.J.; Kauer, J.M.G.

    1992-01-01

    The stiffnesses of the superficial ligaments of 14 human cadaver wrist joints have been determined. In these experiments the tested, fresh-frozen carpal joints are divided into a number of bone-ligament-bone complexes, which are loaded in a tensile testing machine at a rate of 66% of the ligaments'

  14. Motion control of the Twente humanoid head

    NARCIS (Netherlands)

    Visser, L.C.; Carloni, Raffaella; Stramigioli, Stefano

    2009-01-01

    In this work, we present the design and the realization of the motion control algorithm implemented in the Twente hu- manoid head, a seven degrees of freedom (dof) robotic sys- tem. The aim of the project is to have a humanoid head that can serve as a research platform for human-machine interac-

  15. The role of human papilloma virus and p16 in occult primary of the head and neck: a comprehensive review of the literature.

    Science.gov (United States)

    Fotopoulos, George; Pavlidis, Nicholas

    2015-02-01

    Cancer of unknown primary of the head and neck is a challenging entity for the oncologist. The role of human papilloma virus/p16 in carcinogenesis and in prognosis is well established in certain HNSCC especially in that of the oropharynx. In the case of occult primary of the head and neck the role of HPV/p16 positivity is not well defined regarding prognosis and localization of the primary. An independent review of PubMed and ScienceDirect database was performed up to May 2014 using combinations of terms such as "occult primary of the head and neck", "CUP of the head and neck" "metastatic cervical squamous cell carcinoma of unknown primary", "HPV" and "HPV and head and neck cancer". Literature review shows a strong association between HPV/p16 positivity and primary location in the oropharynx in patients with CUP of the head and neck as well as a better clinical outcome. HPV positivity and p16 overexpression could be used as surrogate markers in the search of the primary site of patients with CUP of the head and neck therefore maybe guiding treatment decisions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Introduction of the Canadian CT Head Rule Reduces CT Scan Use ...

    African Journals Online (AJOL)

    amnesia or witnessed disorientation in a patient with a GCS score of 13–15 who has suffered a traumatic event, the evaluation of minor head injury using. Computerized Axial Tomography Scan of the Head. (CT-head) has remained controversial.(1,3). CT–head is expensive, time consuming, strenuous to human resource ...

  17. Clinical and scientific impact of human papillomavirus on head and neck cancer.

    Science.gov (United States)

    Friedman, Jeffrey M; Stavas, Mark J; Cmelak, Anthony J

    2014-10-10

    Head and neck cancer (HNC) arises from the skull base to the clavicles and is the fifth most common cancer in the world by incidence. Historically, in the developed world HNC was associated with tobacco use and alcohol consumption, and the combination of the two produced a synergistic increase in risk. However, beginning in 1983, investigators have found a significant and growing proportion of HNC patients with human papillomavirus-positive (HPV) tumors who neither drank nor used tobacco. Since that time, there has been increased interest in the molecular biology of HPV-positive HNC. Multiple studies now show that HPV has shifted the epidemiological landscape and prognosis of head and neck squamous cell carcinoma (HNSCC). These studies provide strong evidence for improved survival outcomes in patients with HPV-positive HNSCC compared to those with HPV-negative HNSCC. In many reports, HPV status is the strongest predictor of locoregional control, disease specific survival and overall survival. In response to these findings, there has been significant interest in the best management of HPV-positive disease. Discussions within major cooperative groups consider new trials designed to maintain the current strong survival outcomes while reducing the long-term treatment-related toxicities. This review will highlight the epidemiological, clinical and molecular discoveries surrounding HPV-related HNSCC over the recent decades and we conclude by suggesting how these findings may guide future treatment approaches.

  18. Tunical Outer Layer Plays an Essential Role in Penile Veno-occlusive Mechanism Evidenced from Electrocautery Effects to the Corpora Cavernosa in Defrosted Human Cadavers.

    Science.gov (United States)

    Hsieh, Cheng-Hsing; Huang, Yi-Ping; Tsai, Mang-Hung; Chen, Heng-Shen; Huang, Po-Cheng; Lin, Chung-Wu; Hsu, Geng-Long

    2015-12-01

    To determine the exact anatomical structure for establishing penile veno-occlusive function, we sought to conduct a hemodynamic study on defrosted human cadavers. Thirteen penises were used for this experiment, and 11 intact penises were allocated into the electrocautery group (EG, n = 6) and the ligation group (LG, n = 5). A circumcision was made on the penis to access the veins. Two #19 scalp needles were fixed in the 3 and 9 o'clock positions in the distal penis for colloid infusion and intracavernous pressure (ICP) monitoring, respectively. For the EG, the deep dorsal vein and cavernosal vein trunks were freed for 3-5 cm where at least 3 emissary veins were identified via opening Buck's fascia; these veins underwent electrocautery at 45 watts, while the ICP was maintained at 0, 50, 75, 100, 125, and 150 mmHg, respectively. For control, venous ligation was made but at the ICP of 150 mmHg. A tissue block including the emissary vein was then obtained for histological analysis. Except all in the EG and those whose ICP exceed 125 mmHg in the EG, the sinusoids of the corpora cavernosa sustained varied fulgurated fibrosis in every specimen and the severity appeared reversely commensurate with the ICP regarding sinusoidal clumping and darkish bands (P electrocautery damage to intracavernous sinusoids once the ICP reached a level corresponding to a rigid erection. The outer tunica plays an essential role in fulfilling the veno-occlusive mechanism. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Chiasma crurale: intersection of the tibialis posterior and flexor digitorum longus tendons above the ankle. Magnetic resonance imaging-anatomic correlation in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M. [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Institut fuer Diagnostische Radiologie, Zurich (Switzerland); Gheno, Ramon; Nico, Marcelo A.C.; Trudell, Debra J.; Resnick, Donald [VA San Diego Medical Center, Department of Radiology, San Diego, CA (United States); Haghighi, Parviz [VA San Diego Medical Center, Department of Pathology, San Diego, CA (United States)

    2010-06-15

    To determine the precise anatomy and magnetic resonance (MR) imaging appearance of the chiasma crurale in cadavers, paying special attention to degenerative changes Twelve fresh human ankles were harvested from 11 nonembalmed cadavers (mean age at death 77 years) and used according to institutional guidelines. MR imaging and MR tenography were used to investigate the anatomy of the chiasma crurale using proton density-weighted sequences. The gross anatomy of the chiasma crurale was evaluated and compared to the MR imaging findings. Histology was used to elucidate further the structure of the chiasma crurale. Above the chiasma, five specimens had a small amount of fat tissue between the tibialis posterior and flexor digitorum longus tendon. In all specimens both tendons had a sheath below the chiasma but not above it. At the central portion of the chiasma there was no soft tissue between the tendons, except in two specimens that showed an anatomic variant consisting of a thick septum connecting the tibial periosteum and the deep transverse fascia of the leg. In MR images, eight specimens showed what were believed to be degenerative changes in the tendons at the level of the chiasma. However, during gross inspection and histologic analysis of the specimens, there was no tendon degeneration visible. At the central portion of the chiasma, there is no tissue between the tibialis posterior and flexor digitorum longus tendons unless there is an anatomic variant. At the chiasma crurale, areas with irregular tendon surfaces are normal findings and are not associated with tendon degeneration (fraying). (orig.)

  20. Virtual Reality Model of the Three-Dimensional Anatomy of the Cavernous Sinus Based on a Cadaveric Image and Dissection.

    Science.gov (United States)

    Qian, Zeng-Hui; Feng, Xu; Li, Yang; Tang, Ke

    2018-01-01

    Studying the three-dimensional (3D) anatomy of the cavernous sinus is essential for treating lesions in this region with skull base surgeries. Cadaver dissection is a conventional method that has insurmountable flaws with regard to understanding spatial anatomy. The authors' research aimed to build an image model of the cavernous sinus region in a virtual reality system to precisely, individually and objectively elucidate the complete and local stereo-anatomy. Computed tomography and magnetic resonance imaging scans were performed on 5 adult cadaver heads. Latex mixed with contrast agent was injected into the arterial system and then into the venous system. Computed tomography scans were performed again following the 2 injections. Magnetic resonance imaging scans were performed again after the cranial nerves were exposed. Image data were input into a virtual reality system to establish a model of the cavernous sinus. Observation results of the image models were compared with those of the cadaver heads. Visualization of the cavernous sinus region models built using the virtual reality system was good for all the cadavers. High resolutions were achieved for the images of different tissues. The observed results were consistent with those of the cadaver head. The spatial architecture and modality of the cavernous sinus were clearly displayed in the 3D model by rotating the model and conveniently changing its transparency. A 3D virtual reality model of the cavernous sinus region is helpful for globally and objectively understanding anatomy. The observation procedure was accurate, convenient, noninvasive, and time and specimen saving.

  1. Pigeons (C. livia Follow Their Head during Turning Flight: Head Stabilization Underlies the Visual Control of Flight

    Directory of Open Access Journals (Sweden)

    Ivo G. Ros

    2017-12-01

    Full Text Available Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades, and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles.

  2. PAL(TM) 2.0 Human Anatomy Software Tool Use in Community College Traditional and Online Anatomy Laboratory Classes: Student-Perceived Learning Benefits

    Science.gov (United States)

    Kuyatt, Brian Lee

    2012-01-01

    Human anatomy courses, with laboratory, are curricular requirements in graduate medical, undergraduate nursing, and all allied health science programs. Anatomy laboratory courses engage students in hands-on activities, including human cadaver or mammalian dissection, supported by photos from textbooks, detailed plastic models or human anatomical…

  3. Absorbed dose estimates to structures of the brain and head using a high-resolution voxel-based head phantom

    International Nuclear Information System (INIS)

    Evans, Jeffrey F.; Blue, Thomas E.; Gupta, Nilendu

    2001-01-01

    The purpose of this article is to demonstrate the viability of using a high-resolution 3-D head phantom in Monte Carlo N-Particle (MCNP) for boron neutron capture therapy (BNCT) structure dosimetry. This work describes a high-resolution voxel-based model of a human head and its use for calculating absorbed doses to the structures of the brain. The Zubal head phantom is a 3-D model of a human head that can be displayed and manipulated on a computer. Several changes were made to the original head phantom which now contains over 29 critical structures of the brain and head. The modified phantom is a 85x109x120 lattice of voxels, where each voxel is 2.2x2.2x1.4 mm 3 . This model was translated into MCNP lattice format. As a proof of principle study, two MCNP absorbed dose calculations were made (left and right lateral irradiations) using a uniformly distributed neutron disk source with an 1/E energy spectrum. Additionally, the results of these two calculations were combined to estimate the absorbed doses from a bilateral irradiation. Radiobiologically equivalent (RBE) doses were calculated for all structures and were normalized to 12.8 Gy-Eq. For a left lateral irradiation, the left motor cortex receives the limiting RBE dose. For a bilateral irradiation, the insula cortices receive the limiting dose. Among the nonencephalic structures, the parotid glands receive RBE doses that were within 15% of the limiting dose

  4. Simulation of Cardiovascular Response to the Head-Up/Head-Down Tilt at Different Angles

    Science.gov (United States)

    Liu, Yang; Lu, Hong-Bing; Jiao, Chun; Zhang, Li-Fan

    2008-06-01

    The disappearance of hydrostatic pressure is the original factor that causes the changes of cardiovascular system under microgravity. The hydrostatical changes can be simulated by postural changes. Especially the head-down position can be used to simulate the effects of microgravity. The goal of this investigation was to develop a mathematical model for simulation of the human cardiovascular responses to acute and prolonged exposure under microgravity environment. We were particularly interested in the redistribution of transmural pressures, flows, blood volume, and the consequent alterations in local hemodynamics in different cardiovascular compartments during acute exposure and chronic adjustments. As a preliminary study, we first developed a multi-element, distributed hemodynamic model of human cardiovascular system, and verified the model to simulate cardiovascular changes during head up/down tilt at various angles.

  5. Vertebral osteoporosis: perfused animal cadaver model for testing new vertebroplastic agents.

    Science.gov (United States)

    Hoell, Thomas; Huschak, Gerald; Beier, Andre; Holzhausen, Hans-Juergen; Meisel, Hans-Joerg; Emmrich, Frank

    2010-12-01

    Experimental study. It was aimed to establish a cadaver model to imitate osteoporotic perfused vertebral bone and to allow for transpedicular transfer of bone cement and various new materials into vertebrae. The model was perfused to simulate vertebroplasty in the presence of transvertebral blood flow. The injection of bone cement into vertebrae bears the risk of irreversible discharge of material into the venous system of the spinal canal. The bovine cadaver model studied allows visual studies of material distribution in a vertebral bone, the potential spill-out of material, and quantification of washout and disintegration phenomena. Thoracic and lumbar vertebrae from 1-year-old calves were cut transversally into 5 mm slices, macerated, and decalcified. The softened bone slices were compressed between 2 transparent plastic discs. A standard vertebroplasty cannula (outer diameter 3.5 mm, inner diameter 2.5 mm) was inserted into the vertebral body via the pedicle to transfer the different vertebroplasty materials. Arterial blood flow was simulated by means of liquid irrigation via 2 needles in the ventral part of the vertebral body slice. Metal powder was mixed with the solution to indicate the blood flow in the bone. The model was evaluated with the vertebroplasty cement polymethylmethacrylate. The model permitted visualization of the insertion and distribution of vertebroplasty materials. Liquid bone cement was effused into the spinal canal as in the clinical situation. Higher modulus cement acted in the same way as in clinical vertebroplasty. Rigid vertebroplasty agents led to trabecular fractures and stable mechanical interactions with the bone and eventually moved dorsal bone fragments into the spinal canal. Sedimentation of the metal powder indicated regions of perfusion. The model simulated the clinical behavior of liquid and higher modulus vertebroplasty agents in the presence of blood flow. It enabled safe ex vivo testing of the mechanical and physical

  6. Cadaver study of anatomic landmark identification for placing ankle arthroscopy portals.

    Science.gov (United States)

    Scheibling, B; Koch, G; Clavert, P

    2017-05-01

    Arthroscopy-assisted surgery is now widely used at the ankle for osteochondral lesions of the talus, anterior and posterior impingement syndromes, talocrural or subtalar fusion, foreign body removal, and ankle instability. Injuries to the vessels and nerves may occur during these procedures. To determine whether ultrasound topographic identification of vulnerable structures decreased the risk of iatrogenic injuries to vessels, nerves, and tendons and influenced the distance separating vulnerable structures from the arthroscope introduced through four different portals. Ultrasonography to identify vulnerable structures before or during arthroscopic surgery on the ankle may be useful. Twenty fresh cadaver ankles from body donations to the anatomy institute in Strasbourg, France, were divided into two equal groups. Preoperative ultrasonography to mark the trajectories of vessels, nerves, and tendons was performed in one group but not in the other. The portals were created using a 4-mm trocar. Each portal was then dissected. The primary evaluation criterion was the presence or absence of injuries to vessels, nerves, and tendons. The secondary evaluation criterion was the distance between these structures and the arthroscope. No tendon injuries occurred with ultrasonography. Without ultrasonography, there were two full-thickness tendon lesions, one to the extensor hallucis longus and the other to the Achilles tendon. Furthermore, with the anterolateral, anteromedial, and posteromedial portals, the distance separating the vessels and nerves from the arthroscope was greater with than without ultrasonography (P=0.041, P=0.005, and P=0.002), respectively; no significant difference was found with the anterior portal. Preoperative ultrasound topographic identification decreases the risk of iatrogenic injury to the vessels, nerves, and tendons during ankle arthroscopy and places these structures at a safer distance from the arthroscope. Our hypothesis was confirmed. IV

  7. Effects of face/head and whole body cooling during passive heat stress on human somatosensory processing.

    Science.gov (United States)

    Nakata, Hiroki; Namba, Mari; Kakigi, Ryusuke; Shibasaki, Manabu

    2017-06-01

    We herein investigated the effects of face/head and whole body cooling during passive heat stress on human somatosensory processing recorded by somatosensory-evoked potentials (SEPs) at C4' and Fz electrodes. Fourteen healthy subjects received a median nerve stimulation at the left wrist. SEPs were recorded at normothermic baseline (Rest), when esophageal temperature had increased by ~1.2°C (heat stress: HS) during passive heating, face/head cooling during passive heating (face/head cooling: FHC), and after HS (whole body cooling: WBC). The latencies and amplitudes of P14, N20, P25, N35, P45, and N60 at C4' and P14, N18, P22, and N30 at Fz were evaluated. Latency indicated speed of the subcortical and cortical somatosensory processing, while amplitude reflected the strength of neural activity. Blood flow in the internal and common carotid arteries (ICA and CCA, respectively) and psychological comfort were recorded in each session. Increases in esophageal temperature due to HS significantly decreased the amplitude of N60, psychological comfort, and ICA blood flow in the HS session, and also shortened the latencies of SEPs (all, P body temperature. Copyright © 2017 the American Physiological Society.

  8. A Novel Method for Intraoral Access to the Superior Head of the Human Lateral Pterygoid Muscle

    Directory of Open Access Journals (Sweden)

    Aleli Tôrres Oliveira

    2014-01-01

    Full Text Available Background. The uncoordinated activity of the superior and inferior parts of the lateral pterygoid muscle (LPM has been suggested to be one of the causes of temporomandibular joint (TMJ disc displacement. A therapy for this muscle disorder is the injection of botulinum toxin (BTX, of the LPM. However, there is a potential risk of side effects with the injection guide methods currently available. In addition, they do not permit appropriate differentiation between the two bellies of the muscle. Herein, a novel method is presented to provide intraoral access to the superior head of the human LPM with maximal control and minimal hazards. Methods. Computational tomography along with digital imaging software programs and rapid prototyping techniques were used to create a rapid prototyped guide to orient BTX injections in the superior LPM. Results. The method proved to be feasible and reliable. Furthermore, when tested in one volunteer it allowed precise access to the upper head of LPM, without producing side effects. Conclusions. The prototyped guide presented in this paper is a novel tool that provides intraoral access to the superior head of the LPM. Further studies will be necessary to test the efficacy and validate this method in a larger cohort of subjects.

  9. Audiovisual Material as Educational Innovation Strategy to Reduce Anxiety Response in Students of Human Anatomy

    Science.gov (United States)

    Casado, Maria Isabel; Castano, Gloria; Arraez-Aybar, Luis Alfonso

    2012-01-01

    This study presents the design, effect and utility of using audiovisual material containing real images of dissected human cadavers as an innovative educational strategy (IES) in the teaching of Human Anatomy. The goal is to familiarize students with the practice of dissection and to transmit the importance and necessity of this discipline, while…

  10. Primer registro de artropodofauna cadavérica en sustratos humanos y animales en San Juan, Argentina First record of cadaverous arthropod fauna in human and animal substrates in San Juan, Argentina

    Directory of Open Access Journals (Sweden)

    Fernando H. Aballay

    2008-12-01

    Full Text Available En el presente trabajo se estudiaron los artrópodos carroñeros que acudieron a cadáveres de vertebrados al aire libre en la provincia de San Juan, Argentina. El objetivo fue inventariar la composición específica de la artropodofauna cadavérica, asociada a diferentes sustratos de vertebrados en descomposición. Se colectaron muestras de artrópodos sobre restos animales y humanos en condiciones de campo y sobre cadáveres de cerdos domésticos colocados al aire libre bajo condiciones controladas. Se registraron, por primera vez para la provincia de San Juan, 40 especies de artropodofauna tanatológica incluidas en cuatro órdenes y 15 familias. Se incorpora, como primera cita para la fauna forense argentina, un necrófago: Megelenophorus americanus Lacordaire (Coleoptera: Tenebrionidae, y tres necrófilas: Polybia ruficeps Schrottky (Hymenoptera: Vespidae, Pheidole bergi Mayr (Hymenoptera, Formicidae, Myrmicinae y Ectatomma brunneum Smith (Hymenoptera, Formicidae, Ponerinae. Se citan 18 especies necrófagas, 18 necrófilas, una omnívora y seis oportunistas sobre siete diferentes sustratos cadavéricos de vertebrados. Se brindan nuevos registros de distribución de 18 especies de insectos. Se confirma la estacionalidad invernal de Callíphora vicina Robineau-Desvoidy (Diptera: Calliphoridae.In order to determine the specific composition of cadaverous arthropod fauna associated to different decomposing vertebrate substrates, we studied the carrion arthropods that feed on outdoor carcasses in San Juan province, Argentina. Arthropods were collected on animal and human remains in the field and on carcasses of domestic pig placed outdoors under controlled conditions. Forty species of carrion arthropods belonging to four orders and 15 families were recorded for the first time in this province. We present the first record of forensic fauna in Argentina of the necrophagous species Megelenophorus americanus (Coleoptera: Tenebrionidae and three

  11. Five surgical maneuvers on nasal mucosa movement in cleft palate repair: A cadaver study.

    Science.gov (United States)

    Nguyen, Dennis C; Patel, Kamlesh B; Parikh, Rajiv P; Skolnick, Gary B; Woo, Albert S

    2016-06-01

    This biomechanical study aims to characterize the nasal mucosa during palatoplasty, thereby describing the soft tissue attachments at different zones and quantifying movement following their release. Palatal nasal mucosa was exposed and divided in the midline in 10 adult cadaver heads. Five consecutive maneuvers were performed: (1) elevation of nasal mucosa off the maxilla, (2) dissection of nasal mucosa from soft palate musculature, (3) separation of nasal mucosa from palatine aponeurosis, (4) release of mucosa at the pterygopalatine junction, and (5) mobilization of vomer flaps. The mucosal movements across the midline at the midpalate (MP) and posterior nasal spine (PNS) following each maneuver were measured. At the MP, maneuvers 1-4 cumulatively provided 3.8 mm (36.9%), 4.9 mm (47.6%), 6.1 mm (59.2%), and 10.3 mm, respectively. Vomer flap (10.5 mm) elevation led to mobility equivalent to that of maneuvers 1-4 (p = 0.72). At the PNS, cumulative measurements after maneuvers 1-4 were 1.3 mm (10%), 2.4 mm (18.6%), 5.7 mm (44.2%), and 12.9 mm. Here, vomer flaps (6.5 mm) provided less movement (p < 0.001). Maneuver 4 yielded the greatest amount of movement of the lateral nasal mucosa at both MP (4.2 mm, 40.8%) and PNS (7.2 mm, 55.8%). At the MP, complete release of the lateral nasal mucosa achieves as much movement as the vomer flap. At the hard-soft palate junction, the maneuvers progressively add to the movement of the lateral nasal mucosa. The most powerful step is release of attachments along the posterior aspect of the medial pterygoid. Published by Elsevier Ltd.

  12. Oral sex and human papilloma virus-related head and neck squamous cell cancer: a review of the literature.

    Science.gov (United States)

    Shah, Ankit; Malik, Akshat; Garg, Apurva; Mair, Manish; Nair, Sudhir; Chaturvedi, Pankaj

    2017-11-01

    Head neck squamous cell carcinomas (HNSCCs) are a significant cause of morbidity and mortality all around the world. Just like tobacco and alcohol, Human papilloma virus (HPV) infection is now recognized to play a role in the pathogenesis of a subset of HNSCCs. Unprotected sexual behaviours with the HPV carrier plays an important role in transmission of this virus. The global incidence of head and neck cancers is declining, but the incidence of HPV related head and neck cancers is rapidly increasing over the last few decades. However, most institutions do not mandate documentation of sexual history or counselling of patients regarding sexual practices like they do for tobacco and alcohol addictions in HNSCC patients. The aim of this review of literature is to analyse if there is a strong evidence to correlate oral sex with HPV related HNSCC and counsel the patient's regarding sexual behaviours. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. Anatomical study of the proximal origin of hamstring muscles.

    Science.gov (United States)

    Sato, Kengo; Nimura, Akimoto; Yamaguchi, Kumiko; Akita, Keiichi

    2012-09-01

    It is relatively well accepted that the long head of the biceps femoris and the semitendinosus both originate from the ischial tuberosity as a common tendon. However, it is also widely known that the biceps femoris is consistently injured more than the semitendinosus. The purpose of this study was to examine the origins of the hamstring muscles, to find an anatomic basis for diagnosis and treatment of injuries of the posterior thigh regions. Twenty-eight hips of fourteen adult Japanese cadavers were used in this study. In twenty hips of ten cadavers, the positional relationships among the origins on the ischial tuberosity were examined. In eight hips of four cadavers, histological examination of the origins of the hamstrings was also performed. The origin of the long head of the biceps femoris adjoined that of the semitendinosus. In the proximal regions of these muscles, the long head consisted of the tendinous part; however, the semitendinosus mainly consisted of the muscular part. Some of the fibers of the biceps tendon extended to fuse with the sacrotuberous ligament. The semimembranosus muscle broadly originated from the lateral surface of the ischial tuberosity. The origins of the long head of the biceps femoris and the semitendinosus are found to be almost independent, and the tendon of the long head is partly fused with the sacrotuberous ligament. The high incidence of injuries to the long head of the biceps femoris could be explained by these anatomical configurations.

  14. A video, text, and speech-driven realistic 3-d virtual head for human-machine interface.

    Science.gov (United States)

    Yu, Jun; Wang, Zeng-Fu

    2015-05-01

    A multiple inputs-driven realistic facial animation system based on 3-D virtual head for human-machine interface is proposed. The system can be driven independently by video, text, and speech, thus can interact with humans through diverse interfaces. The combination of parameterized model and muscular model is used to obtain a tradeoff between computational efficiency and high realism of 3-D facial animation. The online appearance model is used to track 3-D facial motion from video in the framework of particle filtering, and multiple measurements, i.e., pixel color value of input image and Gabor wavelet coefficient of illumination ratio image, are infused to reduce the influence of lighting and person dependence for the construction of online appearance model. The tri-phone model is used to reduce the computational consumption of visual co-articulation in speech synchronized viseme synthesis without sacrificing any performance. The objective and subjective experiments show that the system is suitable for human-machine interaction.

  15. Development of a new biofidelity ranking system for anthropomorphic test devices.

    Science.gov (United States)

    Rhule, Heather H; Maltese, Matthew R; Donnelly, Bruce R; Eppinger, Rolf H; Brunner, Jill K; Bolte, John H

    2002-11-01

    A new biofidelity assessment system is being developed and applied to three side impact dummies: the WorldSID-alpha, the ES-2 and the SID-HIII. This system quantifies (1) the ability of a dummy to load a vehicle as a cadaver does, "External Biofidelity," and (2) the ability of a dummy to replicate those cadaver responses that best predict injury potential, "Internal Biofidelity." The ranking system uses cadaver and dummy responses from head drop tests, thorax and shoulder pendulum tests, and whole body sled tests. Each test condition is assigned a weight factor based on the number of human subjects tested to form the biomechanical response corridor and how well the biofidelity tests represent FMVSS 214, side NCAP (SNCAP) and FMVSS 201 Pole crash environments. For each response requirement, the cumulative variance of the dummy response relative to the mean cadaver response (DCV) and the cumulative variance of the mean cadaver response relative to the mean plus one standard deviation (CCV) are calculated. The ratio of DCV/CCV expresses how well the dummy response duplicates the mean cadaver response: a smaller ratio indicating better biofidelity. For each test condition, the square root is taken of each Response Comparison Value (DCV/CCV), and then these values are averaged and multiplied by the appropriate Test Condition Weight. The weighted and averaged comparison values are then summed and divided by the sum of the Test Condition Weights to obtain a rank for each body region. Each dummy obtains an overall rank for External Biofidelity and an overall rank for Internal Biofidelity comprised of an average of the ranks from each body region. Of the three dummies studied, the selected comparison test data indicate that the WorldSID-alpha prototype dummy demonstrated the best overall External Biofidelity although improvement is needed in all of the dummies to better replicate human kinematics. All three dummies estimate potential injury assessment with similar levels of

  16. Controversies surrounding Human Papilloma Virus infection, head & neck vs oral cancer, implications for prophylaxis and treatment

    OpenAIRE

    Campisi, G.; Giovannelli, L.

    2009-01-01

    Head & Neck Cancer (HNC) represents the sixth most common malignancy worldwide and it is historically linked to well-known behavioural risk factors, i.e., tobacco smoking and/or the alcohol consumption. Recently, substantial evidence has been mounting that Human Papillomavirus (HPV) infection is playing an increasing important role in oral cancer. Because of the attention and clamor surrounding oral HPV infection and related cancers, as well as the use of HPV prophylactic vaccines, in this in...

  17. The effect of scapular position on subacromial contact behavior: a cadaver study.

    Science.gov (United States)

    Muraki, Takayuki; Yamamoto, Nobuyuki; Sperling, John W; Steinmann, Scott P; Cofield, Robert H; An, Kai-Nan

    2017-05-01

    Patients with subacromial impingement were reported to show abnormal scapular positions during shoulder elevation. However, the relationship between the scapular positions and subacromial impingement is unclear. The purpose of this study was to biomechanically determine the effect of scapular position on subacromial contact behavior by using fresh frozen cadavers. The peak contact pressure on the coracoacromial arch was measured with a flexible tactile force sensor in 9 fresh frozen cadaver shoulders. The measurement was performed during passive glenohumeral elevation in the scapular plane ranging from 30° to 75°. The scapular downward and internal rotations and anterior tilt were simulated by tilting the scapula in 5° increments up to 20°. The measurement was also performed with combination of scapular downward and internal rotations and anterior tilt positions. The peak contact pressure decreased linearly with anterior tilt, and a significant difference between neutral scapular position (1.06 ± 0.89 MPa) and anterior tilt by 20° (0.46 ± 0.18 MPa) was observed (P < .05). However, the scapular positioning in the other directions did not change the peak contact pressure significantly. Furthermore, any combination of abnormal scapular positions did not affect peak contact pressure significantly. Scapular anterior tilt decreased peak contact pressure during passive shoulder elevation. In addition, scapular downward and internal rotations had little effect on peak contact pressure. The abnormal scapular motion reported in previous studies might not be directly related to symptoms caused by subacromial impingement. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. 64Cu-DOTATATE PET for Neuroendocrine Tumors: a Prospective Head-to-Head Comparison with 111In-DTPA-octreotide in 112 Patients

    DEFF Research Database (Denmark)

    Pfeifer, Andreas Klaus; Knigge, Ulrich; Binderup, Tina

    2015-01-01

    Neuroendocrine tumors (NETs) can be visualized using radiolabeled somatostatin analogs. We have previously shown the clinical potential of (64)Cu-DOTATATE in a small first-in-human feasibility study. The aim of the present study was, in a larger prospective design, to compare on a head-to-head ba...

  19. Heading and head injuries in soccer.

    Science.gov (United States)

    Kirkendall, D T; Jordan, S E; Garrett, W E

    2001-01-01

    In the world of sports, soccer is unique because of the purposeful use of the unprotected head for controlling and advancing the ball. This skill obviously places the player at risk of head injury and the game does carry some risk. Head injury can be a result of contact of the head with another head (or other body parts), ground, goal post, other unknown objects or even the ball. Such impacts can lead to contusions, fractures, eye injuries, concussions or even, in rare cases, death. Coaches, players, parents and physicians are rightly concerned about the risk of head injury in soccer. Current research shows that selected soccer players have some degree of cognitive dysfunction. It is important to determine the reasons behind such deficits. Purposeful heading has been blamed, but a closer look at the studies that focus on heading has revealed methodological concerns that question the validity of blaming purposeful heading of the ball. The player's history and age (did they play when the ball was leather and could absorb significant amounts of water), alcohol intake, drug intake, learning disabilities, concussion definition and control group use/composition are all factors that cloud the ability to blame purposeful heading. What does seem clear is that a player's history of concussive episodes is a more likely explanation for cognitive deficits. While it is likely that the subconcussive impact of purposeful heading is a doubtful factor in the noted deficits, it is unknown whether multiple subconcussive impacts might have some lingering effects. In addition, it is unknown whether the noted deficits have any affect on daily life. Proper instruction in the technique is critical because if the ball contacts an unprepared head (as in accidental head-ball contacts), the potential for serious injury is possible. To further our understanding of the relationship of heading, head injury and cognitive deficits, we need to: learn more about the actual impact of a ball on the

  20. Visualization of light propagation in visible Chinese human head for functional near-infrared spectroscopy

    Science.gov (United States)

    Li, Ting; Gong, Hui; Luo, Qingming

    2011-04-01

    Using the visible Chinese human data set, which faithfully represents human anatomy, we visualize the light propagation in the head in detail based on Monte Carlo simulation. The simulation is verified to agree with published experimental results in terms of a differential path-length factor. The spatial sensitivity profile turns out to seem like a fat tropical fish with strong distortion along the folding cerebral surface. The sensitive brain region covers the gray matter and extends to the superficial white matter, leading to a large penetration depth (>3 cm). Finally, the optimal source-detector separation is suggested to be narrowed down to 3-3.5 cm, while the sensitivity of the detected signal to brain activation reaches the peak of 8%. These results indicate that the cerebral cortex folding geometry actually has substantial effects on light propagation, which should be necessarily considered for applications of functional near-infrared spectroscopy.

  1. Mummified trophy heads from Peru: diagnostic features and medicolegal significance.

    Science.gov (United States)

    Verano, John W

    2003-05-01

    Several forms of mummified human trophy heads were produced by prehistoric and historic native groups in South America. This paper describes the diagnostic features of trophy heads produced by the Nasca culture of ancient Peru. A growing interest in these mummified heads among collectors of Pre-Columbian art and antiquities has led to their illegal exportation from Peru, in violation of national and international antiquities laws. Requests from the Peruvian government to protect its cultural patrimony led the United States in 1997 to declare these heads as items subject to U.S. import restriction, along with six other categories of human remains. Despite such restrictions, Nasca trophy heads continue to reach private collectors outside of Peru and thus may be encountered by local, state, or federal law enforcement officials unfamiliar with their characteristic features and origin. The objective of this paper is to describe the features that allow Nasca trophy heads to be identified and distinguished from other archaeological and forensic specimens that may be submitted to a forensic anthropologist for identification.

  2. Axis of eye rotation changes with head-pitch orientation during head impulses about earth-vertical.

    Science.gov (United States)

    Migliaccio, Americo A; Schubert, Michael C; Clendaniel, Richard A; Carey, John P; Della Santina, Charles C; Minor, Lloyd B; Zee, David S

    2006-06-01

    The goal of this study was to assess how the axis of head rotation, Listing's law, and eye position influence the axis of eye rotation during brief, rapid head rotations. We specifically asked how the axis of eye rotation during the initial angular vestibuloocular reflex (VOR) changed when the pitch orientation of the head relative to Earth-vertical was varied, but the initial position of the eye in the orbit and the orientation of Listing's plane with respect to the head were fixed. We measured three-dimensional eye and head rotation axes in eight normal humans using the search coil technique during head-and-trunk (whole-body) and head-on-trunk (head-only) "impulses" about an Earth-vertical axis. The head was initially oriented at one of five pitch angles (30 degrees nose down, 15 degrees nose down, 0 degrees, 15 degrees nose up, 30 degrees nose up). The fixation target was always aligned with the nasooccipital axis. Whole-body impulses were passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 80 degrees /s, and peak-acceleration of approximately 1000 degrees /s2. Head-only impulses were also passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 150 degrees /s, and peak-acceleration of approximately 3000 degrees /s2. During whole-body impulses, the axis of eye rotation tilted in the same direction, and by an amount proportional (0.51 +/- 0.09), to the starting pitch head orientation (P rotation could be predicted from vectorial summation of the gains (eye velocity/head velocity) obtained for rotations about the pure yaw and roll head axes. Thus, even when the orientation of Listing's plane and eye position in the orbit are fixed, the axis of eye rotation during the VOR reflects a compromise between the requirements of Listing's law and a perfectly compensatory VOR.

  3. Knowledge of human papillomavirus and its association with head and neck benign and malignant lesions in a group of dental patients in pakistan.

    Science.gov (United States)

    Gichki, Abdul Samad; Buajeeb, Waranun; Doungudomdacha, Sombhun; Khovidhunkit, Siribang-On Pibooniyom

    2015-01-01

    Human papillomaviruses (HPVs) remain a serious world health problem due to their association with cervical and head and neck cancers. While over 100 HPV types have been identified, only a few subtypes are associated with malignancies. HPV 16 and 18 are the most prevalent oncogenic types in head and neck cancers. Although it has been proven that some subsets of benign and malignant head and neck lesions are associated with HPV, the general population have very little awareness and knowledge of their association with HPV. Therefore, the purpose of this study was to determine the knowledge of HPV and its links with head and neck benign and malignant lesions in a group of Pakistani dental patients who attended the Dental Department of the Sandeman provincial hospital in Quetta, Pakistan. One hundred and ninety-two patients were recruited and requested to answer a questionnaire. It was revealed that there was a low level of knowledge about HPV and its association with head and neck benign and malignant lesions among the participants. This result suggested that more education regarding the relationship of HPV in inducing head and neck benign and malignant lesions is required in this group of patients.

  4. Primary Radiation Therapy for Head-and-Neck Cancer in the Setting of Human Immunodeficiency Virus

    International Nuclear Information System (INIS)

    Klein, Emily A.; Guiou, Michael; Farwell, D. Gregory; Luu, Quang; Lau, Derick H.; Stuart, Kerri; Vaughan, Andrew; Vijayakumar, Srinivasan; Chen, Allen M.

    2011-01-01

    Purpose: To analyze outcomes after radiation therapy for head-and-neck cancer among a cohort of patients with human immunodeficiency virus (HIV). Methods and Materials: The medical records of 12 patients with serologic evidence of HIV who subsequently underwent radiation therapy to a median dose of 68 Gy (range, 64-72 Gy) for newly diagnosed squamous cell carcinoma of the head and neck were reviewed. Six patients (50%) received concurrent chemotherapy. Intensity-modulated radiotherapy was used in 6 cases (50%). All patients had a Karnofsky performance status of 80 or 90. Nine patients (75%) were receiving antiretroviral therapies at the time of treatment, and the median CD4 count was 460 (range, 266-800). Toxicity was graded according to the Radiation Therapy Oncology Group / European Organization for the Treatment of Cancer toxicity criteria. Results: The 3-year estimates of overall survival and local-regional control were 78% and 92%, respectively. Acute Grade 3+ toxicity occurred in 7 patients (58%), the most common being confluent mucositis (5 patients) and moist skin desquamation (4 patients). Two patients experienced greater than 10% weight loss, and none experienced more than 15% weight loss from baseline. Five patients (42%) experienced treatment breaks in excess of 10 cumulative days, although none required hospitalization. There were no treatment-related fatalities. Conclusions: Radiation therapy for head-and-neck cancer seems to be relatively well tolerated among appropriately selected patients with HIV. The observed rates of toxicity were comparable to historical controls without HIV.

  5. Pocket Proteins Suppress Head and Neck Cancer

    Science.gov (United States)

    Shin, Myeong-Kyun; Pitot, Henry C.; Lambert, Paul F.

    2012-01-01

    Head and neck squamous cell carcinomas (HNSCC) is a common cancer in humans long known to be caused by tobacco and alcohol use, but now an increasing percentage of HNSCC is recognized to be caused by the same human papillomaviruses (HPVs) that cause cervical and other anogenital cancers. HPV-positive HNSCCs differ remarkably from HPV-negative HNSCCs in their clinical response and molecular properties. From studies in mice, we know that E7 is the dominant HPV oncoprotein in head and neck cancer. E7 is best known for its ability to inactivate pRb, the product of the retinoblastoma tumor susceptibility gene. However loss of pRb function does not fully account for E7’s potency in causing head and neck cancer. In this study, we characterized the cancer susceptibility of mice deficient in the expression of pRb and either of two related “pocket” proteins, p107 and p130, that are also inactivated by E7. pRb/p107 deficient mice developed head and neck cancer as frequently as do HPV16 E7 transgenic mice. The head and neck epithelia of the pRb/p107 deficient mice also displayed the same acute phenotypes and biomarker readouts as observed in the epithelia of E7 transgenic mice. Mice deficient for pRb and p130 in their head and neck epithelia showed intermediate acute and tumor phenotypes. We conclude that pRb and p107 act together to efficiently suppress head and neck cancer, and are therefore highly relevant targets of HPV16 E7 in its contribution to HPV-positive HNSCC. PMID:22237625

  6. Head-Mounted Display Technology for Low Vision Rehabilitation and Vision Enhancement

    Science.gov (United States)

    Ehrlich, Joshua R.; Ojeda, Lauro V.; Wicker, Donna; Day, Sherry; Howson, Ashley; Lakshminarayanan, Vasudevan; Moroi, Sayoko E.

    2017-01-01

    Purpose To describe the various types of head-mounted display technology, their optical and human factors considerations, and their potential for use in low vision rehabilitation and vision enhancement. Design Expert perspective. Methods An overview of head-mounted display technology by an interdisciplinary team of experts drawing on key literature in the field. Results Head-mounted display technologies can be classified based on their display type and optical design. See-through displays such as retinal projection devices have the greatest potential for use as low vision aids. Devices vary by their relationship to the user’s eyes, field of view, illumination, resolution, color, stereopsis, effect on head motion and user interface. These optical and human factors considerations are important when selecting head-mounted displays for specific applications and patient groups. Conclusions Head-mounted display technologies may offer advantages over conventional low vision aids. Future research should compare head-mounted displays to commonly prescribed low vision aids in order to compare their effectiveness in addressing the impairments and rehabilitation goals of diverse patient populations. PMID:28048975

  7. MR imaging of the ankle at 3 Tesla and 1.5 Tesla: protocol optimization and application to cartilage, ligament and tendon pathology in cadaver specimens

    International Nuclear Information System (INIS)

    Barr, Cameron; Malfair, David; Henning, Tobias D.; Steinbach, Lynne; Link, Thomas M.; Bauer, Jan S.; Ma, Benjamin

    2007-01-01

    The objective of this study was to optimize ankle joint MR imaging in volunteers at 1.5 Tesla (T) and 3.0 T, and to compare these optimized sequences concerning image quality and performance in assessing cartilage, ligament and tendon pathology in fresh human cadaver specimens. Initially our clinical ankle protocol consisting of T1-weighted (-w), fat-saturated (fs) T2-w, and short τ inversion-recovery fast spinecho (FSE) sequences was optimized at 1.5 T and 3.0 T by two radiologists. For dedicated cartilage imaging, fs-intermediate (IM)-w FSE, fs spoiled gradient echo, and balanced free-precession steady-state sequences were optimized. Using the optimized sequences, thirteen cadaver ankle joints were imaged. Four radiologists independently assessed these images concerning image quality and pathology. All radiologists consistently rated image quality higher at 3.0 T (all sequences p<0.05). For detecting cartilage pathology, diagnostic performance was significantly higher at 3.0 T (ROC-values up to 0.93 vs. 0.77; p<0.05); the fs-IM FSE sequence showed highest values among the different sequences. Average sensitivity for detecting tendon pathology was 63% at 3.0 T vs. 41% at 1.5 T and was significantly higher at 3.0 T for 2 out of 4 radiologists (p<0.05). Compared to 1.5 T, imaging of the ankle joint at 3.0 T significantly improved image quality and diagnostic performance in assessing cartilage pathology. (orig.)

  8. Investigating the Prevalence of Human Papilloma Virus in Squamous Cell Carcinoma of the Larynx and Its Correlation with Disease Prognosis.

    Science.gov (United States)

    Atighechi, Saeid; Meybodian, Mojtaba; Dadgarnia, Mohammad Hossein; Baradaranfar, Mohammad Hossein; Behniafard, Nasim

    2016-05-01

    The human papilloma virus (HPV) can play a role in the development of head and neck squamous cell carcinoma (SCC). Our aim was to assess the prevalence of HPV DNA in SCC of the larynx. The impact of HPV infection on patient survival was also evaluated. This case-control study was performed in 44 patients with SCC of the larynx (case group), while the control group comprised samples obtained from cadavers with no previous history of malignancy. A preliminary pathologic evaluation was performed on all samples in the control group (36 samples) to ensure the absence of dysplasia or malignancy. Polymerase chain reaction (PCR) was used to detect HPV DNA. After completing the treatment protocol, patients were followed to assess the impact of HPV infection on overall survival (OS). PCR evaluation in the case group showed that HPV DNA was successfully isolated from 11 (25%) samples, while only two (5.6%) HPV DNA-positive were obtained from cadavers. According to these results, a significant difference was obtained in the prevalence of HPV DNA and laryngeal SCC between cases and controls (P=0.031). No statistically significant difference was observed in the OS of patients with or without HPV infection in the case group (P=0.235). Based on these results, we suggest that the prevalence of HPV infection is higher in laryngeal SCC subjects compared with healthy individuals. Although a longer OS was seen in HPV-positive patients, survival analysis did not show a significant difference in the comparison of HPV-positive and negative findings in SCC patients.

  9. Foundations for a Lifetime: A Qualitative Inquiry into the Recollection, Reconstruction and Meaning-Making Process of Cadaver Dissection

    Science.gov (United States)

    Skinner, Michelle D.

    2013-01-01

    Cadaver dissection has been a central part of the education of medical professionals for centuries. Throughout that time, anatomists have claimed that dissection is a learning experience rich with life lessons encompassing more than simply gross anatomy. Yet, no published empirical data exist of the long-term impact that dissection has on medical…

  10. Human radicular veins : regulation of venous reflux in the absence of valves

    NARCIS (Netherlands)

    van der Kuip, M; Hoogland, P V; Groen, R J

    1999-01-01

    In the literature it is generally assumed that venous reflux within the radicular veins is prevented by the presence of bicuspid valves and narrowing of the transdural part of these vessels. Recently, we performed a human cadaver study of the internal vertebral venous plexus. Surprisingly, a large

  11. Survey of Permethrin and Malathion Resistance in Human Head Lice Populations from Denmark

    DEFF Research Database (Denmark)

    Kristensen, Michael; Knorr, Mette; Rasmussen, Anne-Marie

    2006-01-01

    was selected, 2 ng of permethrin and 100 ng of malathion per head louse, respectively. Head lice were collected from heads of infested children in Denmark at 33 primary schools, one kindergarten, and seven boarding schools. The lice were collected by combing of dry hair, with a fine-toothed antilouse comb...

  12. Cross-sectional anatomy, computed tomography and magnetic resonance imaging of the head of common dolphin (Delphinus delphis) and striped dolphin (Stenella coeruleoalba).

    Science.gov (United States)

    Alonso-Farré, J M; Gonzalo-Orden, M; Barreiro-Vázquez, J D; Barreiro-Lois, A; André, M; Morell, M; Llarena-Reino, M; Monreal-Pawlowsky, T; Degollada, E

    2015-02-01

    Computed tomography (CT) and low-field magnetic resonance imaging (MRI) were used to scan seven by-caught dolphin cadavers, belonging to two species: four common dolphins (Delphinus delphis) and three striped dolphins (Stenella coeruleoalba). CT and MRI were obtained with the animals in ventral recumbency. After the imaging procedures, six dolphins were frozen at -20°C and sliced in the same position they were examined. Not only CT and MRI scans, but also cross sections of the heads were obtained in three body planes: transverse (slices of 1 cm thickness) in three dolphins, sagittal (5 cm thickness) in two dolphins and dorsal (5 cm thickness) in two dolphins. Relevant anatomical structures were identified and labelled on each cross section, obtaining a comprehensive bi-dimensional topographical anatomy guide of the main features of the common and the striped dolphin head. Furthermore, the anatomical cross sections were compared with their corresponding CT and MRI images, allowing an imaging identification of most of the anatomical features. CT scans produced an excellent definition of the bony and air-filled structures, while MRI allowed us to successfully identify most of the soft tissue structures in the dolphin's head. This paper provides a detailed anatomical description of the head structures of common and striped dolphins and compares anatomical cross sections with CT and MRI scans, becoming a reference guide for the interpretation of imaging studies. © 2014 Blackwell Verlag GmbH.

  13. Nintendo Wii remote controllers for head posture measurement: accuracy, validity, and reliability of the infrared optical head tracker.

    Science.gov (United States)

    Kim, Jongshin; Nam, Kyoung Won; Jang, Ik Gyu; Yang, Hee Kyung; Kim, Kwang Gi; Hwang, Jeong-Min

    2012-03-15

    To evaluate the accuracy, validity, and reliability of a newly developed infrared optical head tracker (IOHT) using Nintendo Wii remote controllers (WiiMote; Nintendo Co. Ltd., Kyoto, Japan) for measurement of the angle of head posture. The IOHT consists of two infrared (IR) receivers (WiiMote) that are fixed to a mechanical frame and connected to a monitoring computer via a Bluetooth communication channel and an IR beacon that consists of four IR light-emitting diodes (LEDs). With the use of the Cervical Range of Motion (CROM; Performance Attainment Associates, St. Paul, MN) as a reference, one- and three-dimensional (1- and 3-D) head postures of 20 normal adult subjects (20-37 years of age; 9 women and 11 men) were recorded with the IOHT. In comparison with the data from the CROM, the IOHT-derived results showed high consistency. The measurements of 1- and 3-D positions of the human head with the IOHT were very close to those of the CROM. The correlation coefficients of 1- and 3-D positions between the IOHT and the CROM were more than 0.99 and 0.96 (P < 0.05, Pearson's correlation test), respectively. Reliability tests of the IOHT for the normal adult subjects for 1- and 3-D positions of the human head had 95% limits of agreement angles of approximately ±4.5° and ±8.0°, respectively. The IOHT showed strong concordance with the CROM and relatively good test-retest reliability, thus proving its validity and reliability as a head-posture-measuring device. Considering its high performance, ease of use, and low cost, the IOHT has the potential to be widely used as a head-posture-measuring device in clinical practice.

  14. Comparison of in vivo vs. frozen vs. Thiel cadaver specimens in visualisation of anatomical structures of the ankle on proton density Magnetic Resonance Imaging (MRI) through a visual grading analysis (VGA) study

    International Nuclear Information System (INIS)

    Zarb, F.; McNulty, J.; Gatt, A.; Formosa, C.; Chockalingam, N.; Evanoff, M.G.; Rainford, L.

    2017-01-01

    Purpose: The use of cadavers for medical education purposes and for radiology research methodologies which involve subjective image quality evaluation of anatomical criteria is well documented. The aim of this study was to quantify the impact of cadaver tissue preservation in producing MR images that are representative of living tissue by comparing the visualisation of anatomical structures of the ankle obtained from live and cadaver (fresh frozen and Thiel embalmed) specimens through a visual grading analysis (VGA) study. Methods: A VGA study was conducted on an image data set consisting of 4 coronal proton density weighted (PDw) sequences obtained from ankles of a live patient and those of a cadaveric specimen, of which the right ankle was frozen and the left Thiel embalmed. Results: Comparison of the image quality scores obtained from: the live patient vs. the Thiel specimen indicate a significant difference (p ≤ 0.05) between the scores in favour of the Thiel specimen; between the live patient vs. the frozen specimen indicate a significant difference (p ≤ 0.05) in favour of the frozen specimen and between the frozen vs. the Thiel specimen indicate a significant difference (p ≤ 0.05) in favour of the Thiel specimen. Conclusions: The advantages of the use of cadavers (frozen or Thiel embalmed) has been shown to also apply for use with proton density (PD) MR imaging. The preservation of cadavers especially using Thiel is a suitable alternative for MRI optimisation and protocol development purposes. - Highlights: • Thiel preservation: a better alternative compared to frozen methods for MR image analysis. • VGA demonstrated an efficient research study design for the investigation of embalming methods. • Thiel embalmed cadavers: an acceptable alternative from patients for MR imaging optimisation. • Additional MR sequences and increased sample sizes are recommended for further investigation.

  15. Intrathecal Spread of Injectate Following an Ultrasound-Guided Selective C5 Nerve Root Injection in a Human Cadaver Model.

    Science.gov (United States)

    Falyar, Christian R; Abercrombie, Caroline; Becker, Robert; Biddle, Chuck

    2016-04-01

    Ultrasound-guided selective C5 nerve root blocks have been described in several case reports as a safe and effective means to anesthetize the distal clavicle while maintaining innervation of the upper extremity and preserving diaphragmatic function. In this study, cadavers were injected with 5 mL of 0.5% methylene blue dye under ultrasound guidance to investigate possible proximal and distal spread of injectate along the brachial plexus, if any. Following the injections, the specimens were dissected and examined to determine the distribution of dye and the structures affected. One injection revealed dye extended proximally into the epidural space, which penetrated the dura mater and was present on the spinal cord and brainstem. Dye was noted distally to the divisions in 3 injections. The anterior scalene muscle and phrenic nerve were stained in all 4 injections. It appears unlikely that local anesthetic spread is limited to the nerve root following an ultrasound-guided selective C5 nerve root injection. Under certain conditions, intrathecal spread also appears possible, which has major patient safety implications. Additional safety measures, such as injection pressure monitoring, should be incorporated into this block, or approaches that are more distal should be considered for the acute pain management of distal clavicle fractures.

  16. Further evidence on the anatomical placement of the human eyeball for facial approximation and craniofacial superimposition.

    Science.gov (United States)

    Stephan, Carl N; Huang, Anne J R; Davidson, Paavi L

    2009-03-01

    Recently a small sampled cadaver study (n = 4) suggested that the human eyeballs are placed closer to the orbital roof and lateral orbital wall as first reported in the anatomical literature many years previously. This contrasts with central positioning of the eyeball within the orbit as advocated by the facial approximation literature. Given the limits of such small samples, this study re-examined globe position in nine new cadavers to help clarify which relationship is accurate. The results essentially confirm prior empirical findings except that the mean lateral divergences from the orbit center were found to be larger--the eyeball was found to be "displaced" 1.4 mm superiorly and 2.4 mm laterally. Medians calculated across all 13 cadavers from this study and the above-mentioned recent report refine these measurements to 1.4 and 2.3 mm respectively. Globe projection values were identical to those observed for living individuals (c. 16 mm).

  17. Effect of lavage and brush preparation on cement penetration and primary stability in tibial unicompartmental total knee arthroplasty: An experimental cadaver study.

    Science.gov (United States)

    Scheele, Christian; Pietschmann, Matthias F; Schröder, Christian; Grupp, Thomas; Holderied, Melanie; Jansson, Volmar; Müller, Peter E

    2017-03-01

    Unicompartmental total knee arthroplasty (UKA) is a well-established treatment option for unicondylar osteoarthritis, and generally leads to better functional results than tricompartimental total knee arthroplasty (TKA). However, revision rates of UKAs are reported as being higher; a major reason for this is aseptic loosening of the tibial component due to implant-cement-bone interface fatigue. The objective of this study was to determine the effects of trabecular bone preparation, prior to implantation of tibial UKAs, on morphological and biomechanical outcomes in a cadaver study. Cemented UKAs were performed in 18 human cadaver knees after the bone bed was cleaned using pulsed lavage (Group A), conventional brush (Group B) or no cleaning at all (Group C, control). Morphologic cement penetration and primary stability were measured. The area proportion under the tibial component without visible cement penetration was significantly higher in Group C (21.9%, SD 11.9) than in both Group A (7.1%, SD 5.8), and Group B (6.5%, SD 4.2) (P=0.007). The overall cement penetration depth did not differ between groups. However, in the posterior part, cement penetration depth was significantly higher in Group B (1.9mm, SD 0.3) than in both Group A (1.3mm, SD 0.3) and Group C (1.4mm, SD 0.3) (P=0.015). The mode of preparation did not show a substantial effect on primary stability tested under dynamic compression-shear test conditions (P=0.910). Bone preparation significantly enhances cement interdigitation. The application of a brush shows similar results compared with the application of pulsed lavage. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Precise Head Tracking in Hearing Applications

    Science.gov (United States)

    Helle, A. M.; Pilinski, J.; Luhmann, T.

    2015-05-01

    The paper gives an overview about two research projects, both dealing with optical head tracking in hearing applications. As part of the project "Development of a real-time low-cost tracking system for medical and audiological problems (ELCoT)" a cost-effective single camera 3D tracking system has been developed which enables the detection of arm and head movements of human patients. Amongst others, the measuring system is designed for a new hearing test (based on the "Mainzer Kindertisch"), which analyzes the directional hearing capabilities of children in cooperation with the research project ERKI (Evaluation of acoustic sound source localization for children). As part of the research project framework "Hearing in everyday life (HALLO)" a stereo tracking system is being used for analyzing the head movement of human patients during complex acoustic events. Together with the consideration of biosignals like skin conductance the speech comprehension and listening effort of persons with reduced hearing ability, especially in situations with background noise, is evaluated. For both projects the system design, accuracy aspects and results of practical tests are discussed.

  19. Regional differences in islet distribution in the human pancreas--preferential beta-cell loss in the head region in patients with type 2 diabetes.

    Directory of Open Access Journals (Sweden)

    Xiaojun Wang

    Full Text Available While regional heterogeneity in islet distribution has been well studied in rodents, less is known about human pancreatic histology. To fill gaps in our understanding, regional differences in the adult human pancreas were quantitatively analyzed including the pathogenesis of type 2 diabetes (T2D. Cadaveric pancreas specimens were collected from the head, body and tail regions of each donor, including subjects with no history of diabetes or pancreatic diseases (n = 23 as well as patients with T2D (n = 12. The study further included individuals from whom islets were isolated (n = 7 to study islet yield and function in a clinical setting of islet transplantation. The whole pancreatic sections were examined using an innovative large-scale image capture and unbiased detailed quantitative analyses of the characteristics of islets from each individual (architecture, size, shape and distribution. Islet distribution/density is similar between the head and body regions, but is >2-fold higher in the tail region. In contrast to rodents, islet cellular composition and architecture were similar throughout the pancreas and there was no difference in glucose-stimulated insulin secretion in islets isolated from different regions of the pancreas. Further studies revealed preferential loss of large islets in the head region in patients with T2D. The present study has demonstrated distinct characteristics of the human pancreas, which should provide a baseline for the future studies integrating existing research in the field and helping to advance bi-directional research between humans and preclinical models.

  20. Return of the cadaver: Key role of anatomic dissection for plastic surgery resident training.

    Science.gov (United States)

    Krähenbühl, Swenn Maxence; Čvančara, Paul; Stieglitz, Thomas; Bonvin, Raphaël; Michetti, Murielle; Flahaut, Marjorie; Durand, Sébastien; Deghayli, Lina; Applegate, Lee Ann; Raffoul, Wassim

    2017-07-01

    Successful Plastic Surgery Residency training is subjected to evolving society pressure of lower hourly work weeks imposed by external committees, labor laws, and increased public awareness of patient care quality. Although innovative measures for simulation training of surgery are appearing, there is also the realization that basic anatomy training should be re-enforced and cadaver dissection is of utmost importance for surgical techniques.In the development of new technology for implantable neurostimulatory electrodes for the management of phantom limb pain in amputee patients, a design of a cadaveric model has been developed with detailed steps for innovative transfascicular insertion of electrodes. Overall design for electrode and cable implantation transcutaneous was established and an operating protocol devised.Microsurgery of the nerves of the upper extremities for interfascicular electrode implantation is described for the first time. Design of electrode implantation in cadaver specimens was adapted with a trocar delivery of cables and electrodes transcutaneous and stabilization of the electrode by suturing along the nerve. In addition, the overall operating arena environment with specific positions of the multidisciplinary team necessary for implantable electrodes was elaborated to assure optimal operating conditions and procedures during the organization of a first-in-man implantation study.Overall importance of plastic surgery training for new and highly technical procedures is of importance and particularly there is a real need to continue actual cadaveric training due to patient variability for nerve anatomic structures.

  1. Studies on the metabolism of five model drugs by fungi colonizing cadavers using LC-ESI-MS/MS and GC-MS analysis.

    Science.gov (United States)

    Martínez-Ramírez, Jorge A; Voigt, Kerstin; Peters, Frank T

    2012-09-01

    It is well-known that cadavers may be colonized by microorganisms, but there is limited information if or to what extent these microbes are capable of metabolizing drugs or poisons, changing the concentrations and metabolic pattern of such compounds in postmortem samples. The aim of the present study was to develop a fungal biotransformation system as an in vitro model to investigate potential postmortem metabolism by fungi. Five model drugs (amitriptyline, metoprolol, mirtazapine, promethazine, and zolpidem) were each incubated with five model fungi known to colonize cadavers (Absidia repens, Aspergillus repens, Aspergillus terreus, Gliocladium viride, and Mortierella polycephala) and with Cunninghamella elegans (positive control). Incubations were performed in Sabouraud medium at 25 °C for 5 days. After centrifugation, a part of the supernatants was analyzed by liquid chromatography-tandem mass spectrometry with product ion scanning. Another part was analyzed by full scan gas chromatography-mass spectrometry after extraction and derivatization. All model drugs were metabolized by the control fungus resulting in two (metoprolol) to ten (amitriptyline) metabolites. Of the model fungi, only Abs. repens and M. polycephala metabolized the model drugs: amitriptyline was metabolized to six and five, metoprolol to two and two, mirtazapine to five and three, promethazine to six and nine, and zolpidem to three and four metabolites, respectively. The main metabolic reactions were demethylation, oxidation, and hydroxylation. The presented in vitro model is applicable to studying drug metabolism by fungi colonizing cadavers.

  2. The estimation of 3D SAR distributions in the human head from mobile phone compliance testing data for epidemiological studies

    International Nuclear Information System (INIS)

    Wake, Kanako; Watanabe, Soichi; Taki, Masao; Varsier, Nadege; Wiart, Joe; Mann, Simon; Deltour, Isabelle; Cardis, Elisabeth

    2009-01-01

    A worldwide epidemiological study called 'INTERPHONE' has been conducted to estimate the hypothetical relationship between brain tumors and mobile phone use. In this study, we proposed a method to estimate 3D distribution of the specific absorption rate (SAR) in the human head due to mobile phone use to provide the exposure gradient for epidemiological studies. 3D SAR distributions due to exposure to an electromagnetic field from mobile phones are estimated from mobile phone compliance testing data for actual devices. The data for compliance testing are measured only on the surface in the region near the device and in a small 3D region around the maximum on the surface in a homogeneous phantom with a specific shape. The method includes an interpolation/extrapolation and a head shape conversion. With the interpolation/extrapolation, SAR distributions in the whole head are estimated from the limited measured data. 3D SAR distributions in the numerical head models, where the tumor location is identified in the epidemiological studies, are obtained from measured SAR data with the head shape conversion by projection. Validation of the proposed method was performed experimentally and numerically. It was confirmed that the proposed method provided good estimation of 3D SAR distribution in the head, especially in the brain, which is the tissue of major interest in epidemiological studies. We conclude that it is possible to estimate 3D SAR distributions in a realistic head model from the data obtained by compliance testing measurements to provide a measure for the exposure gradient in specific locations of the brain for the purpose of exposure assessment in epidemiological studies. The proposed method has been used in several studies in the INTERPHONE.

  3. Human Cloning

    Science.gov (United States)

    2006-07-20

    Human Fertilization and Embryology Authority (HFEA). A team of scientists headed by Alison Murdoch at the University of Newcastle received permission...not yet reported success in isolating stem cells from a cloned human embryo. A research team headed by Ian Wilmut at the University of Edinburgh...research group, headed by Douglas Melton and Kevin Eggan, submitted their proposal to a Harvard committee composed of ethicists, scientists and public

  4. Hoffa's recess: incidence, morphology and differential diagnosis of the globular-shaped cleft in the infrapatellar fat pad of the knee on MRI and cadaver dissections

    International Nuclear Information System (INIS)

    Vahlensieck, M.; Linneborn, G.; Schild, H.H.; Schmidt, H.-M.

    2002-01-01

    We frequently observed a fluid-like indentation at the inferior posterior margin of Hoffa's fat pad of the knee and sought to establish the incidence and differential diagnostic criteria of this cleft. In total, 133 MRI studies and 35 cadaver specimens were analyzed for the location, size, and shape of clefts at the inferior posterior margin of Hoffa's fat pad. The incidence of a fluid-like ovoid cleft on MR images was 13.5% and in cadavers 14.3%. The cleft was located just below the insertion of the infrapatellar synovial fold (plica synovialis infrapatellaris, ligamentum mucosum). More linear-shaped indentations at the posterior margin were visible in all patients and cadavers due to the horizontal course of the alar folds. A fluid-filled indentation within the inferior posterior margin of Hoffa's fat pad has to be expected in more than 10% of knee studies and should not be confused with tumors like ganglion cysts. We term this cleft the infrahoffatic recess. One hypothesis of its origin concerns the embryological regression process of the infrapatellar membrane into the infrapatellar synovial fold. It should not be confused with linear clefts due to the alar folds. (orig.)

  5. Gene Expression Changes in Femoral Head Necrosis of Human Bone Tissue

    Directory of Open Access Journals (Sweden)

    Bernadett Balla

    2011-01-01

    Full Text Available Osteonecrosis of the femoral head (ONFH is the result of an interruption of the local circulation and the injury of vascular supply of bone. Multiple factors have been implicated in the development of the disease. However the mechanism of ischemia and necrosis in non-traumatic ONFH is not clear. The aim of our investigation was to identify genes that are differently expressed in ONFH vs. non-ONFH human bone and to describe the relationships between these genes using multivariate data analysis. Six bone tissue samples from ONFH male patients and 8 bone tissue samples from non-ONFH men were examined. The expression differences of selected 117 genes were analyzed by TaqMan probe-based quantitative real-time RT-PCR system. The significance test indicated marked differences in the expression of nine genes between ONFH and non-ONFH individuals. These altered genes code for collagen molecules, an extracellular matrix digesting metalloproteinase, a transcription factor, an adhesion molecule, and a growth factor. Canonical variates analysis demonstrated that ONFH and non-ONFH bone tissues can be distinguished by the multiple expression profile analysis of numerous genes controlled via canonical TGFB pathway as well as genes coding for extracellular matrix composing collagen type molecules. The markedly altered gene expression profile observed in the ONFH of human bone tissue may provide further insight into the pathogenetic process of osteonecrotic degeneration of bone.

  6. Factors affecting the aluminium content of human femoral head and neck.

    Science.gov (United States)

    Zioła-Frankowska, Anetta; Dąbrowski, Mikołaj; Kubaszewski, Łukasz; Rogala, Piotr; Frankowski, Marcin

    2015-11-01

    Tissues for the study were obtained intraoperatively during hip replacement procedures from 96 patients. In all the cases, the indication for this treatment was primary or secondary degenerative changes in the hip joint. The subject of the study was the head and neck of the femur, resected in situ. Aluminium concentrations measured in femoral head and neck samples from patients aged between 25 and 91 were varied. Statistical methods were applied to determine the variations in relation to the parameters from the background survey. Significant differences in the aluminium content of femoral head samples were observed between patients under and over 60 years of age. Based on the results, it was confirmed that the aluminium accumulates in bones over a lifetime. The study showed that the content of aluminium in the head and neck of the femur depends on the factors such as: type of medicines taken, contact with chemicals at work, differences in body anatomy and sex. The study on the levels of aluminium in bones and the factors affecting its concentration is a valuable source of information for further research on the role of aluminium in bone diseases. Based on the investigations, it was found that the GF-AAS technique is the best analytical tool for routine analysis of aluminium in complex matrix samples. The use of femoral heads in the investigations was approved by the Bioethics Committee of the University of Medical Sciences in Poznań (Poland). Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Fixed-angle plates in patella fractures - a pilot cadaver study

    Directory of Open Access Journals (Sweden)

    Wild M

    2011-01-01

    Full Text Available Abstract Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge, quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65. Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays

  8. The preservation of a cadaver by a clay sealant: Implications for the disposal of nuclear fuel waste

    International Nuclear Information System (INIS)

    Lee, C.F.; Oscarson, D.W.; Cheung, S.C.H.

    1986-01-01

    This report documents a case history in which a cadaver and the associated burial objects were found well preserved after being buried for more than 2100 years in Southern China. The preservation is attributed to a layer of kaolin that surrounded the coffin and served as a barrier to water and air movement. The implications for the disposal of nuclear fuel waste are discussed

  9. Modelling and assessment of the electric field strength caused by mobile phone to the human head

    Directory of Open Access Journals (Sweden)

    Buckus Raimondas

    2016-01-01

    Full Text Available Background/Aim. Electromagnetic field exposure is the one of the most important physical agents that actively affects live organisms and environment. Active use of mobile phones influences the increase of electromagnetic field radiation. The aim of the study was to measure and assess the electric field strength caused by mobile phones to the human head. Methods. In this paper the software “COMSOL Multiphysics” was used to establish the electric field strength created by mobile phones around the head. Results. The second generation (2G Global System for Mobile (GSM phones that operate in the frequency band of 900 MHz and reach the power of 2 W have a stronger electric field than (2G GSM mobile phones that operate in the higher frequency band of 1,800 MHz and reach the power up to 1 W during conversation. The third generation of (3G UMTS smart phones that effectively use high (2,100 MHz radio frequency band emit the smallest electric field strength values during conversation. The highest electric field strength created by mobile phones is around the ear, i.e. the mobile phone location. The strength of mobile phone electric field on the phantom head decreases exponentially while moving sidewards from the center of the effect zone (the ear, and constitutes 1-12% of the artificial head’s surface. Conclusion. The highest electric field strength values of mobile phones are associated with their higher power, bigger specific energy absorption rate (SAR and lower frequency of mobile phone. The stronger electric field emitted by the more powerful mobile phones takes a higher percentage of the head surface. The highest electric field strength created by mobile phones is distributed over the user ear.

  10. Mechanical properties of the human scalp in tension.

    Science.gov (United States)

    Falland-Cheung, Lisa; Scholze, Mario; Lozano, Pamela F; Ondruschka, Benjamin; Tong, Darryl C; Brunton, Paul A; Waddell, J Neil; Hammer, Niels

    2018-08-01

    Mechanical properties of the human scalp have not been investigated to a great extent with limited information available. The purpose of this study was to provide new baseline material data for human scalp tissue of various ages, which can be applied to experimental and constitutive models, such as in the area of impact biomechanics. This study used specimens from the left and right temporal, fronto-parietal and occipital regions of the human scalp. It investigated the tensile behavior of scalp tissue using tissues harvested from unfixed, fresh cadavers. These samples were subjected to an osmotic stress analysis and upon testing, cyclic loading followed by stretching until failure in a universal testing machine. Strain evaluation was conducted using digital image correlation in a highly standardized approach. Elastic modulus, tensile strength, strain at maximum load and strain to failure were evaluated computationally. No significant differences were observed comparing the tensile strength between males and females. In contrast to that, a sex-dependent difference was found for the elastic modulus of the occipital scalp region and for the elongation properties. Additionally, regional differences within the male group, as well as an age dependent correlation for females were found in the elastic modulus and tensile strength. Scanning electron microscope analyses have shown the ultrastructural failure patterns, indicated by damaged keratin plates, as well as partially disrupted and retraced collagens at the failure site. The novel data obtained in this study could add valuable information to be used for modeling purposes, as well as provide baseline data for simulant materials and comparisons of tissue properties following head injury or forensic investigations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Automatic annotation of head velocity and acceleration in Anvil

    DEFF Research Database (Denmark)

    Jongejan, Bart

    2012-01-01

    We describe an automatic face tracker plugin for the ANVIL annotation tool. The face tracker produces data for velocity and for acceleration in two dimensions. We compare the annotations generated by the face tracking algorithm with independently made manual annotations for head movements....... The annotations are a useful supplement to manual annotations and may help human annotators to quickly and reliably determine onset of head movements and to suggest which kind of head movement is taking place....

  12. Administrative Strategies of Departmental Heads as Determinants for the Effective Management of Human Resources in Tertiary Institutions in Delta State, Nigeria

    Science.gov (United States)

    Osakwe, Regina N.

    2015-01-01

    This study investigated administrative strategies of departmental heads as determinants of effective management of human resources in tertiary institutions. Four research questions were asked and four hypotheses were formulated to guide the study. As a descriptive survey, the population comprised all the eight tertiary institutions in the state…

  13. Insects feeding on cadavers as an alternative source of human genetic material

    Directory of Open Access Journals (Sweden)

    Rafał Skowronek

    2015-03-01

    Full Text Available In some criminal cases, the use of classical sources of human genetic material is difficult or even impossible. One solution may be the use of insects, especially blowfly larvae which feed on corpses. A recent review of case reports and experimental studies available in biomedical databases has shown that insects can be a valuable source of human mitochondrial and genomic deoxyribonucleic acid (DNA, allowing for an effective analysis of hypervariable region (HVR sequences and short tandem repeat (STR profiles, respectively. The optimal source of human DNA is the crop (a part of the gut of active third-instar blowfly larvae. Pupae and insect faeces can be also used in forensic genetic practice instead of the contents of the alimentary tract.

  14. Development and validation of a human biomechanical model for rib fracture and thorax injuries in blunt impact.

    Science.gov (United States)

    Cai, Zhihua; Lan, Fengchong; Chen, Jiqing

    2015-07-01

    From 1990 to approximately 50,000-120,000 people die annually of road traffic accidents in China. Traffic accidents are the main cause of death of Chinese adults aged 15-45 years. This study aimed to determine the biomechanical response and injury tolerance of the human body in traffic accidents. The subject was a 35-year-old male with a height of 170 cm, weight of 70 kg and Chinese characteristics at the 50th percentile. Geometry was generated by computed tomography and magnetic resonance imaging. A human-body biomechanical model was then developed. The model featured in great detail the main anatomical characteristics of skeletal tissues, soft tissues and internal organs, including the head, neck, shoulder, thoracic cage, abdomen, spine, pelvis, pleurae and lungs, heart, aorta, arms, legs, and other muscle tissues and skeletons. The material properties of all tissues in the human body model were obtained from the literature. Material properties were developed in the LS-DYNA code to simulate the mechanical behaviour of the biological tissues in the human body. The model was validated against cadaver responses to frontal and side impact. The predicted model response reasonably agreed with the experimental data, and the model can further be used to evaluate thoracic injury in real-world crashes. We believe that the transportation industry can use numerical models in the future to simultaneously reduce physical testing and improve automotive safety.

  15. Volume and planar gated cardiac magnetic resonance imaging: a correlative study of normal anatomy with Thallium-201 SPECT and cadaver sections

    International Nuclear Information System (INIS)

    Go, R.T.; MacIntyre, W.J.; Yeung, H.N.

    1984-01-01

    Magnetic resonance (MR) gated cardiac imaging was performed in ten subjects using a prototype 0.15-T resistive magnet imaging system. Volume and planar imaging techniques utilizing saturation recovery, proton TI-weighted relaxation time pulse sequences produced images of the heart and great vessels with exquisite anatomic detail that showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with the thallium-201 cardiac single photon emission computed tomography images. Volume acquisition allowed postprocessing selection of tomographic sections in various orientations to optimize visualization of a particular structure of interest. The excellent spatial and contrast resolution afforded by MR volume imaging, which does not involve the use of ionizing radiation and iodinated contrast material, should assure it a significant role in the diagnostic assessment of the cardiovascular system

  16. Analysis of linear head accelerations from collegiate football impacts.

    Science.gov (United States)

    Brolinson, P Gunnar; Manoogian, Sarah; McNeely, David; Goforth, Mike; Greenwald, Richard; Duma, Stefan

    2006-02-01

    Sports-related concussions result in 300,000 brain injuries in the United States each year. We conducted a study utilizing an in-helmet system that measures and records linear head accelerations to analyze head impacts in collegiate football. The Head Impact Telemetry (HIT) System is an in-helmet system with six spring-mounted accelerometers and an antenna that transmits data via radio frequency to a sideline receiver and laptop computer system. A total of 11,604 head impacts were recorded from the Virginia Tech football team throughout the 2003 and 2004 football seasons during 22 games and 62 practices from a total of 52 players. Although the incidence of injury data are limited, this study presents an extremely large data set from human head impacts that provides valuable insight into the lower limits of head acceleration that cause mild traumatic brain injuries.

  17. Development of Realistic Head Models for Electromagnetic Source Imaging of the Human Brain

    National Research Council Canada - National Science Library

    Akalin, Z

    2001-01-01

    In this work, a methodology is developed to solve the forward problem of electromagnetic source imaging using realistic head models, For this purpose, first segmentation of the 3 dimensional MR head...

  18. Anatomy and Humanity: Examining the Effects of a Short Documentary Film and First Anatomy Laboratory Experience on Medical Students

    Science.gov (United States)

    Dosani, Farah; Neuberger, Lindsay

    2016-01-01

    Medical students begin their education inside a laboratory dissecting cadavers to learn human gross anatomy. Many schools use the course experience as a way to instill empathy and some have begun integrating video and recorded interviews with body donors to humanize the experience, but their impact has yet to be measured. This study examines the…

  19. Porcine cadaver iris model for iris heating during corneal surgery with a femtosecond laser

    Science.gov (United States)

    Sun, Hui; Fan, Zhongwei; Wang, Jiang; Yan, Ying; Juhasz, Tibor; Kurtz, Ron

    2015-03-01

    Multiple femtosecond lasers have now been cleared for use for ophthalmic surgery, including for creation of corneal flaps in LASIK surgery. Preliminary study indicated that during typical surgical use, laser energy may pass beyond the cornea with potential effects on the iris. As a model for laser exposure of the iris during femtosecond corneal surgery, we simulated the temperature rise in porcine cadaver iris during direct illumination by the femtosecond laser. Additionally, ex-vivo iris heating due to femtosecond laser irradiation was measured with an infrared thermal camera (Fluke corp. Everett, WA) as a validation of the simulation.

  20. Flexible nine-channel photodetector probe facilitated intraspinal multisite transcutaneous photobiomodulation therapy dosimetry in cadaver dogs

    Science.gov (United States)

    Piao, Daqing; Sypniewski, Lara A.; Bailey, Christian; Dugat, Danielle; Burba, Daniel J.; De Taboada, Luis

    2018-01-01

    Noninvasive photobiomodulation therapy (PBMT) of spinal cord disease remains speculative due to the lack of evidence for whether photobiomodulatory irradiances can be transcutaneously delivered to the spinal cord under a clinically acceptable PBMT surface irradiation protocol. We developed a flexible nine-channel photodetection probe for deployment within the spinal canal of a cadaver dog after hemilaminectomy to measure transcutaneously transmitted PBMT irradiance at nine sites over an eight-cm spinal canal length. The probe was built upon a 6.325-mm tubular stem, to the surface of which nine photodiodes were epoxied at approximately 1 cm apart. The photodiode has a form factor of 4.80 mm×2.10 mm×1.15 mm (length×width×height). Each photodiode was individually calibrated to deliver 1 V per 7.58 μW/cm2 continuous irradiance at 850 nm. The outputs of eight photodiodes were logged concurrently using a data acquisition module interfacing eight channels of differential analog signals, while the output of the ninth photodiode was measured by a precision multimeter. This flexible probe rendered simultaneous intraspinal (nine-site) measurements of transcutaneous PBMT irradiations at 980 nm in a pilot cadaver dog model. At a surface continuous irradiance of 3.14 W/cm2 applied off-contact between L1 and L2, intraspinal irradiances picked up by nine photodiodes had a maximum of 327.48 μW/cm2 without the skin and 5.68 μW/cm2 with the skin.

  1. Modeling heading and path perception from optic flow in the case of independently moving objects

    Science.gov (United States)

    Raudies, Florian; Neumann, Heiko

    2013-01-01

    Humans are usually accurate when estimating heading or path from optic flow, even in the presence of independently moving objects (IMOs) in an otherwise rigid scene. To invoke significant biases in perceived heading, IMOs have to be large and obscure the focus of expansion (FOE) in the image plane, which is the point of approach. For the estimation of path during curvilinear self-motion no significant biases were found in the presence of IMOs. What makes humans robust in their estimation of heading or path using optic flow? We derive analytical models of optic flow for linear and curvilinear self-motion using geometric scene models. Heading biases of a linear least squares method, which builds upon these analytical models, are large, larger than those reported for humans. This motivated us to study segmentation cues that are available from optic flow. We derive models of accretion/deletion, expansion/contraction, acceleration/deceleration, local spatial curvature, and local temporal curvature, to be used as cues to segment an IMO from the background. Integrating these segmentation cues into our method of estimating heading or path now explains human psychophysical data and extends, as well as unifies, previous investigations. Our analysis suggests that various cues available from optic flow help to segment IMOs and, thus, make humans' heading and path perception robust in the presence of such IMOs. PMID:23554589

  2. Use of necrophagous insects as evidence of cadaver relocation: myth or reality?

    Science.gov (United States)

    Gosselin, Matthias; Hedouin, Valéry

    2017-01-01

    The use of insects as indicators of post-mortem displacement is discussed in many texts, courses and TV shows, and several studies addressing this issue have been published. Although the concept is widely cited, it is poorly understood, and only a few forensic cases have successfully applied such a method. The use of necrophagous insects as evidence of cadaver relocation actually involves a wide range of biological aspects. Distribution, microhabitat, phenology, behavioral ecology, and molecular analysis are among the research areas associated with this topic. This article provides the first review of the current knowledge and addresses the potential and limitations of different methods to evaluate their applicability. This work reveals numerous weaknesses and erroneous beliefs as well as many possibilities and research opportunities. PMID:28785513

  3. Use of necrophagous insects as evidence of cadaver relocation: myth or reality?

    Directory of Open Access Journals (Sweden)

    Damien Charabidze

    2017-08-01

    Full Text Available The use of insects as indicators of post-mortem displacement is discussed in many texts, courses and TV shows, and several studies addressing this issue have been published. Although the concept is widely cited, it is poorly understood, and only a few forensic cases have successfully applied such a method. The use of necrophagous insects as evidence of cadaver relocation actually involves a wide range of biological aspects. Distribution, microhabitat, phenology, behavioral ecology, and molecular analysis are among the research areas associated with this topic. This article provides the first review of the current knowledge and addresses the potential and limitations of different methods to evaluate their applicability. This work reveals numerous weaknesses and erroneous beliefs as well as many possibilities and research opportunities.

  4. Preference Bias of Head Orientation in Choosing between Two Non-durables

    Directory of Open Access Journals (Sweden)

    Hiroyuki eFunaya

    2015-06-01

    Full Text Available The goal of this study is to investigate how customers’ gaze, head and body orientations reflect their choices. Although the relationship between human choice and gaze behavior has been well studied, other behaviors such as head and body are unknown. We conducted a two-alternatives-forced-choice task to examine (1 whether preference bias, i.e. a positional bias in gaze, head and body toward the item that was later chosen, exists in choice, (2 when preference bias is observed and when prediction of the resulting choice becomes possible (3 whether human choice is affected when the body orientations are manipulated. We used real non-durable products (cheap snacks and clothing on a shopping shelf. The results showed that there was a significant preference bias in head orientation at the beginning one second when the subjects stood straight toward the shelf, and that the head orientation was more biased toward the selected item than the gaze and the center of pressure at the ending one second. Manipulating body orientation did not affect the result of choice. The preference bias detected by observing the head orientation would be useful in marketing science for predicting customers’ choice.

  5. Preference bias of head orientation in choosing between two non-durables.

    Science.gov (United States)

    Funaya, Hiroyuki; Shibata, Tomohiro

    2015-01-01

    The goal of this study is to investigate how customers' gaze, head and body orientations reflect their choices. Although the relationship between human choice and gaze behavior has been well-studied, other behaviors such as head and body are unknown. We conducted a two-alternatives-forced-choice task to examine (1) whether preference bias, i.e., a positional bias in gaze, head and body toward the item that was later chosen, exists in choice, (2) when preference bias is observed and when prediction of the resulting choice becomes possible (3) whether human choice is affected when the body orientations are manipulated. We used real non-durable products (cheap snacks and clothing) on a shopping shelf. The results showed that there was a significant preference bias in head orientation at the beginning 1 s when the subjects stood straight toward the shelf, and that the head orientation was more biased toward the selected item than the gaze and the center of pressure at the ending 1 s. Manipulating body orientation did not affect the result of choice. The preference bias detected by observing the head orientation would be useful in marketing science for predicting customers' choice.

  6. Primer registro de artropodofauna cadavérica en sustratos humanos y animales en San Juan, Argentina

    Directory of Open Access Journals (Sweden)

    Fernando H. ABALLAY

    2008-01-01

    Full Text Available En el presente trabajo se estudiaron los artrópodos carroñeros que acudieron a cadáveres de vertebrados al aire libre en la provincia de San Juan, Argentina. El objetivo fue inventariar la composición específica de la artropodofauna cadavérica, asociada a diferentes sustratos de vertebrados en descomposición. Se colectaron muestras de artrópodos sobre restos animales y humanos en condiciones de campo y sobre cadáveres de cerdos domésticos colocados al aire libre bajo condiciones controladas. Se registraron, por primera vez para la provincia de San Juan, 40 especies de artropodofauna tanatológica incluidas en cuatro órdenes y 15 familias. Se incorpora, como primera cita para la fauna forense argentina, un necrófago: Megelenophorus americanus Lacordaire (Coleoptera: Tenebrionidae, y tres necrófilas: Polybia ruficeps Schrottky (Hymenoptera: Vespidae, Pheidole bergi Mayr (Hymenoptera, Formicidae, Myrmicinae y Ectatomma brunneum Smith (Hymenoptera, Formicidae, Ponerinae. Se citan 18 especies necrófagas, 18 necrófilas, una omnívora y seis oportunistas sobre siete diferentes sustratos cadavéricos de vertebrados. Se brindan nuevos registros de distribución de 18 especies de insectos. Se confirma la estacionalidad invernal de Callíphora vicina Robineau-Desvoidy (Diptera: Calliphoridae.

  7. Investigating the Prevalence of Human Papilloma Virus in Squamous Cell Carcinoma of the Larynx and Its Correlation with Disease Prognosis

    Directory of Open Access Journals (Sweden)

    Saeid Atighechi

    2016-05-01

    Full Text Available Introduction: The human papilloma virus (HPV can play a role in the development of head and neck squamous cell carcinoma (SCC. Our aim was to assess the prevalence of HPV DNA in SCC of the larynx. The impact of HPV infection on patient survival was also evaluated.  Materials and Methods: This case-control study was performed in 44 patients with SCC of the larynx (case group, while the control group comprised samples obtained from cadavers with no previous history of malignancy. A preliminary pathologic evaluation was performed on all samples in the control group (36 samples to ensure the absence of dysplasia or malignancy. Polymerase chain reaction (PCR was used to detect HPV DNA. After completing the treatment protocol, patients were followed to assess the impact of HPV infection on overall survival (OS.  Results: PCR evaluation in the case group showed that HPV DNA was successfully isolated from 11 (25% samples, while only two (5.6% HPV DNA-positive were obtained from cadavers. According to these results, a significant difference was obtained in the prevalence of HPV DNA and laryngeal SCC between cases and controls (P=0.031. No statistically significant difference was observed in the OS of patients with or without HPV infection in the case group (P=0.235.  Conclusion: Based on these results, we suggest that the prevalence of HPV infection is higher in laryngeal SCC subjects compared with healthy individuals. Although a longer OS was seen in HPV-positive patients, survival analysis did not show a significant difference in the comparison of HPV-positive and negative findings in SCC patients.

  8. The Relationship between Robot's Nonverbal Behaviour and Human's Likability Based on Human's Personality.

    Science.gov (United States)

    Thepsoonthorn, Chidchanok; Ogawa, Ken-Ichiro; Miyake, Yoshihiro

    2018-05-30

    At current state, although robotics technology has been immensely developed, the uncertainty to completely engage in human-robot interaction is still growing among people. Many current studies then started to concern about human factors that might influence human's likability like human's personality, and found that compatibility between human's and robot's personality (expressions of personality characteristics) can enhance human's likability. However, it is still unclear whether specific means and strategy of robot's nonverbal behaviours enhances likability from human with different personality traits and whether there is a relationship between robot's nonverbal behaviours and human's likability based on human's personality. In this study, we investigated and focused on the interaction via gaze and head nodding behaviours (mutual gaze convergence and head nodding synchrony) between introvert/extravert participants and robot in two communication strategies (Backchanneling and Turn-taking). Our findings reveal that the introvert participants are positively affected by backchanneling in robot's head nodding behaviour, which results in substantial head nodding synchrony whereas the extravert participants are positively influenced by turn-taking in gaze behaviour, which leads to significant mutual gaze convergence. This study demonstrates that there is a relationship between robot's nonverbal behaviour and human's likability based on human's personality.

  9. Assessment of a new hydrophilic acrylic supplementary IOL for sulcus fixation in pseudophakic cadaver eyes

    Science.gov (United States)

    Reiter, N; Werner, L; Guan, J; Li, J; Tsaousis, K T; Mamalis, N; Srinivasan, S

    2017-01-01

    Purpose Management of refractive errors after cataract surgery includes spectacles or contact lens, secondary laser vision correction, intraocular lens (IOL) exchange, or piggyback lens implantation. We evaluated for the first time a single-piece hydrophilic acrylic IOL designed for supplementary sulcus fixation in postmortem pseudophakic human eyes. Methods Pseudophakic human cadaver eyes were imaged by anterior segment optical coherence tomography (AS-OCT) to assess position of the primary IOL. Eyes were prepared as per the Miyake-Apple technique. The supplementary IOL (Medicontur A4 Addon IOL family) was then inserted into the ciliary sulcus. AS-OCT and photographs from anterior and posterior views were used to assess IOL centration, tilt, and interlenticular distance from the primary IOL. Results Data were obtained from 12 eyes having primary IOLs of varying materials and designs in the bag and representing different sizes of eyes and severity of Soemmering's ring formation. The A4 Addon IOL was successfully inserted into the ciliary sulcus and was well centered in all cases. Four cases of tilt were observed on AS-OCT: three with mild tilt due to pre-existing zonular dehiscence, and one due to a localized area of Soemmering's ring formation. Interlenticular distance ranged from 0.34 to 1.24 mm and was not dependent on severity of Soemmering's ring or type of primary IOL. Conclusions The A4 Addon IOL was designed for sulcus fixation as a supplementary lens, with a large diameter, a square-shaped optic, four smooth loop haptics, and a convex–concave optical surface. It exhibited appropriate centration and interlenticular distance with different primary in-the-bag IOLs. PMID:28106890

  10. Design and fabrication of a realistic anthropomorphic heterogeneous head phantom for MR purposes.

    Directory of Open Access Journals (Sweden)

    Sossena Wood

    Full Text Available The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications.An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application that involves electromagnetic-tissue interactions: MRI (due to it being an available resource. The developed phantom was filled with media possessing electromagnetic constitutive parameters that correspond to biological tissues at ~297 MHz. A preliminary comparison between an in-vivo human volunteer (based on whom the anthropomorphic head phantom was created and various phantoms types, one being the anthropomorphic heterogeneous head phantom, were performed using a 7 Tesla human MRI scanner.Echo planar imaging was performed and minimal ghosting and fluctuations were observed using the proposed anthropomorphic phantom. The magnetic field distributions (during MRI experiments at 7 Tesla and the scattering parameter (measured using a network analyzer were most comparable between the anthropomorphic heterogeneous head phantom and an in-vivo human volunteer.The developed anthropomorphic heterogeneous head phantom can be used as a resource to various researchers in applications that involve electromagnetic-biological tissue interactions such as MRI.

  11. Feasibility and implementation of a literature information management system for human papillomavirus in head and neck cancers with imaging.

    Science.gov (United States)

    Wu, Dee H; Matthiesen, Chance L; Alleman, Anthony M; Fournier, Aaron L; Gunter, Tyler C

    2014-01-01

    This work examines the feasibility and implementation of information service-orientated architecture (ISOA) on an emergent literature domain of human papillomavirus, head and neck cancer, and imaging. From this work, we examine the impact of cancer informatics and generate a full set of summarizing clinical pearls. Additionally, we describe how such an ISOA creates potential benefits in informatics education, enhancing utility for creating enduring digital content in this clinical domain.

  12. Comparison of Ventilation With One-Handed Mask Seal With an Intraoral Mask Versus Conventional Cuffed Face Mask in a Cadaver Model: A Randomized Crossover Trial.

    Science.gov (United States)

    Amack, Andrew J; Barber, Gary A; Ng, Patrick C; Smith, Thomas B; April, Michael D

    2017-01-01

    We compare received minute volume with an intraoral mask versus conventional cuffed face mask among medics obtaining a 1-handed mask seal on a cadaver model. This study comprised a randomized crossover trial of adult US Army combat medic volunteers participating in a cadaver laboratory as part of their training. We randomized participants to obtain a 1-handed mask seal during ventilation of a fresh unembalmed cadaver, first using either an intraoral airway device or conventional cuffed face mask. Participants obtained a 1-handed mask seal while a ventilator delivered 10 standardized 750-mL breaths during 1 minute. After a 5-minute rest period, they repeated the study with the alternative mask. The primary outcome measure was received minute volume as measured by a respirometer. Of 27 recruited participants, all completed the study. Median received minute volume was higher with the intraoral mask compared with conventional cuffed mask by 1.7 L (95% confidence interval 1.0 to 1.9 L; Pcadaver model. The intraoral mask may prove a useful airway adjunct for ventilation. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  13. Visual perception of axes of head rotation

    Science.gov (United States)

    Arnoldussen, D. M.; Goossens, J.; van den Berg, A. V.

    2013-01-01

    Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. (1) Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit. We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow's rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals. (2) Do transformed visual self-rotation signals reflect the arrangement of the semi-circular canals (SCC)? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those Blood oxygenated level-dependent (BOLD) signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes. (3) We investigated if subject's sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is

  14. Visual perception of axes of head rotation

    Directory of Open Access Journals (Sweden)

    David Mattijs Arnoldussen

    2013-02-01

    Full Text Available Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. 1. Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit.We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow’s rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals.2. Do transformed visual self-rotation signals reflect the arrangement of the semicircular canals (SCC? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those BOLD signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes.3. We investigated if subject’s sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is not arranged into

  15. Tensile Properties of the Deep Transverse Metatarsal Ligament in Hallux Valgus: A CONSORT-Compliant Article.

    Science.gov (United States)

    Abdalbary, Sahar Ahmed; Elshaarawy, Ehab A A; Khalid, Bahaa E A

    2016-02-01

    The deep transverse metatarsal ligament (DTML) connects the neighboring2 metatarsal heads and is one of the stabilizers connecting the lateral sesamoid and second metatarsal head. In this study, we aimed to determine the tensile properties of the DTML in normal specimens and to compare these results with hallux valgus specimens. We hypothesized that the tensile properties of the DTML would be different between the 2 groups of specimens.The DTML in the first interspace was dissected from 12 fresh frozen human cadaveric specimens. Six cadavers had bilateral hallux valgus and the other 6 cadavers had normal feet. The initial length (L0) and cross-sectional area (A0) of the DTML were measured using a digital caliper, and tensile tests with load failure were performed using a material testing machine.There were significant between-groups differences in the initial length (L0) P = 0.009 and cross-sectional area (A0) of the DTML P = 0.007. There were also significant between-groups differences for maximum force (N) P = 0.004, maximum distance (mm) P = 0.005, maximum stress (N/mm) P = 0.003, and maximum strain (%) P = 0.006.The DTML is an anatomical structure for which the tensile properties differ in hallux valgus.

  16. Heads Up

    Science.gov (United States)

    ... Connect with Us HEADS UP Apps Reshaping the Culture Around Concussion in Sports Get HEADS UP on Your Web Site Concussion ... HEADS UP on your web site! Create a culture of safety for young athletes Officials, learn how you can ... UP to Providers HEADS UP to Youth Sports HEADS UP to School Sports HEADS UP to ...

  17. Integration of basic science and clinical medicine: the innovative approach of the cadaver biopsy project at the Boston University School of Medicine.

    Science.gov (United States)

    Eisenstein, Anna; Vaisman, Lev; Johnston-Cox, Hillary; Gallan, Alexander; Shaffer, Kitt; Vaughan, Deborah; O'Hara, Carl; Joseph, Lija

    2014-01-01

    Curricular integration has emerged as a consistent theme in medical education reform. Vertical integration of topics such as pathology offers the potential to bring basic science content into the clinical arena, but faculty/student acceptance and curricular design pose challenges for such integration. The authors describe the Cadaver Biopsy Project (CBP) at Boston University School of Medicine as a sustainable model of vertical integration. Faculty and select senior medical students obtained biopsies of cadavers during the first-year gross anatomy course (fall 2009) and used these to develop clinical cases for courses in histology (spring 2010), pathology (fall 2010-spring 2011), and radiology (fall 2011 or spring 2012), thereby linking students' first experiences in basic sciences with other basic science courses and later clinical courses. Project goals included engaging medical stu dents in applying basic science princi ples in all aspects of patient care as they acquire skills. The educational intervention used a patient (cadaver)-centered approach and small-group, collaborative, case-based learning. Through this project, the authors involved clinical and basic science faculty-plus senior medical students-in a collaborative project to design and implement an integrated curriculum through which students revisited, at several different points, the microscopic structure and pathophysiology of common diseases. Developing appropriate, measurable out comes for medical education initiatives, including the CBP, is challenging. Accumu lation of qualitative feedback from surveys will guide continuous improvement of the CBP. Documenting longer-term impact of the curricular innovation on test scores and other competency-based outcomes is an ultimate goal.

  18. Management of chest deformity caused by microtia reconstruction: Comparison of autogenous diced cartilage versus cadaver cartilage graft partial filling techniques.

    Science.gov (United States)

    Go, Ju Young; Kang, Bo Young; Hwang, Jin Hee; Oh, Kap Sung

    2017-01-01

    Efforts to prevent chest wall deformity after costal cartilage graft are ongoing. In this study, we introduce a new method to prevent donor site deformation using irradiated cadaver cartilage (ICC) and compare this method to the autogenous diced cartilage (ADC) technique. Forty-two pediatric patients comprised the ADC group (n = 24) and the ICC group (n = 18). After harvesting costal cartilage, the empty perichondrial space was filled with autologous diced cartilage in the ADC group and cadaver cartilage in the ICC group. Digital photographs and rib cartilage three-dimensional computed tomography (CT) data were analyzed to compare the preventive effect of donor site deformity. We compared the pre- and postoperative costal cartilage volumes using 3D-CT and graded the volumes (grade I: 0%-25%, grade II: 25%-50%, grade III: 50%-75%, and grade IV: 75%-100%). The average follow-up period was 20 and 24 months in the ADC and ICC groups, respectively. Grade IV maintenance of previous costal cartilage volume was evident postoperatively in 22% of patients in the ADC group and 82% of patients in the ICC group. Intercostal space narrowing and chest wall depression were less in the ICC group. There were no complications or severe resorption of cadaver cartilage. ICC support transected costal ring and prevented stability loss by acting as a spacer. The ICC technique is more effective in preventing intercostal space narrowing and chest wall depression than the ADC technique. Samsung Medical Center Institution Review Board, Unique protocol ID: 2009-10-006-008. This study is also registered on PRS (ClinicalTrials.gov Record 2009-10-006). Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  19. Renewing Head Start's Promise: Invest in What Works for Disadvantaged Preschoolers

    Science.gov (United States)

    Mead, Sara

    2014-01-01

    Since Head Start's last reauthorization in 2007, the Department of Health and Human Services, which oversees Head Start, has implemented significant reforms that are improving the program. In "Renewing Head Start's Promise: Invest in What Works for Disadvantaged Preschoolers," Sara Mead offers several recommendations to enable…

  20. Visualizing Iron Deposition in Multiple Sclerosis Cadaver Brains

    International Nuclear Information System (INIS)

    Habib, Charbel A.; Zheng Weili; Mark Haacke, E.; Webb, Sam; Nichol, Helen

    2010-01-01

    Aim: To visualize and validate iron deposition in two cases of multiple sclerosis using rapid scanning X-Ray Fluorescence (RS-XRF) and Susceptibility Weighted Imaging (SWI). Material and Methods: Two (2) coronal cadaver brain slices from patients clinically diagnosed with multiple sclerosis underwent magnetic resonance imaging (MRI), specifically SWI to image iron content. To confirm the presence of iron deposits and the absence of zinc-rich myelin in lesions, iron and zinc were mapped using RS-XRF. Results: MS lesions were visualized using FLAIR and correlated with the absence of zinc by XRF. XRF and SWI showed that in the first MS case, there were large iron deposits proximal to the draining vein of the caudate nucleus as well as iron deposits associated with blood vessels throughout the globus pallidus. Less iron was seen in association with lesions than in the basal ganglia. The presence of larger amounts of iron correlated reasonably well between RS-XRF and SWI. In the second case, the basal ganglia appeared normal and acute perivascular iron deposition was absent. Conclusion: Perivascular iron deposition is seen in some but not all MS cases, giving credence to the use of SWI to assess iron involvement in MS pathology in vivo.

  1. Realistic Avatar Eye and Head Animation Using a Neurobiological Model of Visual Attention

    National Research Council Canada - National Science Library

    Itti, L; Dhavale, N; Pighin, F

    2003-01-01

    We describe a neurobiological model of visual attention and eye/head movements in primates, and its application to the automatic animation of a realistic virtual human head watching an unconstrained...

  2. SizeChina : A 3D Anthropometric Survey of the Chinese Head

    NARCIS (Netherlands)

    Ball, R.M.

    2011-01-01

    Problem The design of consumer products that are worn on the head relies on the availability of accurate anthropometric information describing the shape and size of the human head and face. Historical anthropometric studies with univariate data have documented the existence of shape differences

  3. Segmentation process significantly influences the accuracy of 3D surface models derived from cone beam computed tomography

    NARCIS (Netherlands)

    Fourie, Zacharias; Damstra, Janalt; Schepers, Rutger H; Gerrits, Pieter; Ren, Yijin

    AIMS: To assess the accuracy of surface models derived from 3D cone beam computed tomography (CBCT) with two different segmentation protocols. MATERIALS AND METHODS: Seven fresh-frozen cadaver heads were used. There was no conflict of interests in this study. CBCT scans were made of the heads and 3D

  4. Morphology and morphometry of the human sublingual glands in mouth floor enlargements of edentulous patients

    Directory of Open Access Journals (Sweden)

    Josiane Costa Rodrigues de SA

    2013-12-01

    Full Text Available Asymptomatic mouth floor enlargements may be observed in edentulous patients. These masses, which protrude from the mouth floor, may complicate the fitting of dentures and require surgery. Whether this "entity" may be considered an anatomical variation of the mouth floor or represent specific alterations in the sublingual gland is not known. Objective: The aim of this work is to investigate the morphological and morphometric aspects of the sublingual glands of edentulous patients with mouth floor enlargements and compare the glands of these patients with the sublingual glands of human cadavers. Material and Methods: Microscopic evaluation was performed on human sublingual glands from edentulous patients with mouth floor enlargements (n=20 and edentulous cadavers (n=20. The patients and cadavers were of similar ages. The data were compared using Mann-Whitney U, Fisher's exact and Student's t tests (p0.05. Only the variables "autolysis" and "congested blood vessels" presented statistical difference between groups (p=0.014; p=0.043. The morphometric study revealed that the volume densities of acini, ducts, stroma and adipose tissue were similar between the groups (p>0.05. CONCLUSION: The microscopic characteristics of the sublingual glands in mouth floor enlargements in edentulous patients correspond to characteristics associated with the normal aging process. The glands are not pathological and represent an age-related alteration that occurs with or without the presence of the mouth floor enlargements.

  5. Proteome reference map of Drosophila melanogaster head.

    Science.gov (United States)

    Lee, Tian-Ren; Huang, Shun-Hong; Lee, Chi-Ching; Lee, Hsiao-Yun; Chan, Hsin-Tzu; Lin, Kuo-Sen; Chan, Hong-Lin; Lyu, Ping-Chiang

    2012-06-01

    Drosophila melanogaster has been used as a genetic model organism to understand the fundamental molecular mechanisms in human biology including memory formation that has been reported involving protein synthesis and/or post-translational modification. In this study, we employed a proteomic platform based on fluorescent 2DE and MALDI-TOF MS to build a standard D. melanogaster head proteome map for proteome-proteome comparison. In order to facilitate the comparison, an interactive database has been constructed for systematically integrating and analyzing the proteomes from different conditions and further implicated to study human diseases related to D. melanogaster model. In summary, the fundamental head proteomic database and bioinformatic analysis will be useful for further elucidating the biological mechanisms such as memory formation and neurodegenerative diseases. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Musical preferences and learning outcome of medical students in cadaver dissection laboratory: A Nigerian survey.

    Science.gov (United States)

    Anyanwu, G E; Nto, J N; Agu, A U; Ekezie, J; Esom, E A

    2016-11-01

    Background music has been reported to enhance learning in the cadaver dissection laboratory. This study was designed to determine the impact of various forms of musical genre and some of their characteristics on students' learning outcome in the dissection laboratory. Some selected musical genre in vocal and non-vocal forms and at different tempi and volume were played as background music (BM) to 253 Medical and Dental students during various sessions of cadaver dissection. Psychological Stress assessment was done using Psychological stress measure-9. Participants love for music, preferred musical genre and other musical characteristics were assessed. The impact of the various musical genre and their characteristics on learning was done via written examination on the region dissected during each musical session. A positive relationship was noted between students' preference for musical genre during leisure with their preference for BM during private study time (Pmusical genre on some selected learning factors. Country and Classical music gave the highest positive impact on the various learning factors in CDL followed by R&B. No significant difference was noted between the cognitive values of vocal and non-vocal music. Classical music most effectively reduced the stress induced by dissection in the CDL while Reggae and High life musical genre created a more stressful environment than regular background noise (Pmusical genre and their various characteristics. The inability to isolate the particular musical genre with these desired properties could account for the controversies in the reports of the role of music in academic environment. Copyright © 2016 Elsevier GmbH. All rights reserved.

  7. Modeling Heading and Path Perception from Optic Flow in the Case of Independently Moving Objects

    Directory of Open Access Journals (Sweden)

    Florian eRaudies

    2013-04-01

    Full Text Available Humans are usually accurate when estimating heading or path from optic flow, even in the presence of independently moving objects (IMO in an otherwise rigid scene. To invoke significant biases in perceived heading, IMOs have to be large and obscure the focus of expansion (FOE in the image plane, which is the point of approach. For the estimation of path during curvilinear self-motion no significant biases were found in the presence of IMOs. What makes humans robust in their estimation of heading or path using optic flow? We derive analytical models of optic flow for linear and curvilinear self-motion using geometric scene models. Heading biases of a linear least squares method, which builds upon these analytical models, are large, larger than those reported for humans. This motivated us to study segmentation cues that are available from optic flow. We derive models of accretion / deletion, expansion / contraction, acceleration / deceleration, local spatial curvature, and local temporal curvature, to be used as cues to segment an IMO from the background. Integrating these segmentation cues into our method of estimating heading or path now explains human psychophysical data and extends, as well as unifies, previous investigations. Our analysis suggests that various cues available from optic flow help to segment IMOs and, thus, make humans’ heading and path perception robust in the presence of such IMOs.

  8. Development and initial porcine and cadaver experience with three-dimensional printing of endoscopic and laparoscopic equipment.

    Science.gov (United States)

    del Junco, Michael; Okhunov, Zhamshid; Yoon, Renai; Khanipour, Ramtin; Juncal, Samuel; Abedi, Garen; Lusch, Achim; Landman, Jaime

    2015-01-01

    Recent advances in three-dimensional (3D) printing technology have made it possible to print surgical devices. We report our initial experience with the printing and deployment of endoscopic and laparoscopic equipment. We created computer-aided designs for ureteral stents and laparoscopic trocars using SolidWorks. We developed three generations of stents, which were printed with an Objet500 Connex printer, and a fourth generation was printed with an EOSINT P395 printer. The trocars were printed with an Objet30 Pro printer. We deployed the printed stents and trocars in a female cadaver and in vivo porcine model. We compared the printed trocars to two standard trocars for defect area and length using a digital caliper. Paired T-tests and ANOVA were used to test for statistical difference. The first two generations of stents (7F and 9F) were functional failures as their diminutive inner lumen failed to allow the passage of a 0.035 guidewire. The third generation 12F stent allowed passage of a 0.035 guidewire. The 12F diameter limited its deployment, but it was introduced in a cadaver through a ureteral access sheath. The fourth-generation 9F stents were printed and deployed in a porcine model using the standard Seldinger technique. The printed trocars were functional for the maintenance of the pneumoperitoneum and instrument passage. The printed trocars had larger superficial defect areas (pcadaver models. Three-dimensional printing is rapidly advancing and may be clinically viable in the future.

  9. Can the gracilis be used to replace the anterior cruciate ligament in the knee? A cadaver study.

    Science.gov (United States)

    Cavaignac, Etienne; Pailhé, Regis; Murgier, Jérôme; Reina, Nicolas; Lauwers, Frederic; Chiron, Philippe

    2014-12-01

    The purpose of this study was to evaluate whether a four-strand gracilis-only graft can be used in anterior cruciate ligament (ACL) reconstruction. Cadaver study. This study involved 16 cadaver knees. The length and diameter of the native ACL were measured in each one. The same measurements were performed on a four-strand graft of the gracilis only, the semitendinosus only and both tendons. Student's t-test was used to compare the various conditions. The average diameter of the G4 construct was 0.07 mm greater (1%) than the native ACL (p=0.044). The average cross-sectional area of the G4 construct was 1.2 mm(2) greater (3.9%) than the native ACL (p=0.049). The G4 was on average 38.9 mm longer than the intra-articular portion of the ACL (p<0.001). A four-strand gracilis construct meets the anatomical specifications for use as an ACL reconstruction graft. By using the gracilis only, the morbidity associated with harvesting the gracilis and semitendinosus tendons should be reduced. Further studies must be performed to compare the biomechanical properties of this graft with other graft types and also to evaluate how this four-strand gracilis graft behaves in a clinical setting. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Dynamic head-neck stabilization and modulation with perturbation bandwidth investigated using a multisegment neuromuscular model

    NARCIS (Netherlands)

    Happee, R. (Riender); de Bruijn, E. (Edo); Forbes, P.A. (Patrick A.); F.C.T. van der Helm (Frans C.)

    2017-01-01

    textabstractThe human head-neck system requires continuous stabilization in the presence of gravity and trunk motion. We investigated contributions of the vestibulocollic reflex (VCR), the cervicocollic reflex (CCR), and neck muscle co-contraction to head-in-space and head-on-trunk stabilization,

  11. Dynamic head-neck stabilization and modulation with perturbation bandwidth investigated using a multisegment neuromuscular model

    NARCIS (Netherlands)

    Happee, R.; de Bruijn, E.; Forbes, P.A.; van der Helm, F.C.T.

    2017-01-01

    The human head-neck system requires continuous stabilization in the presence of gravity and trunk motion. We investigated contributions of the vestibulocollic reflex (VCR), the cervicocollic reflex (CCR), and neck muscle co-contraction to head-in-space and head-on-trunk stabilization, and

  12. Comparison of swallowing outcomes of laryngotracheal separation versus total laryngectomy in a validated ovine model of profound oropharyngeal dysphagia.

    Science.gov (United States)

    Venkatesan, N N; Johnson, C M; Siddiqui, M T; Cates, D J; Kuhn, M A; Postma, G N; Belafsky, P C

    2017-04-01

    To validate the ovine model of profound oropharyngeal dysphagia and compare swallowing outcomes of laryngotracheal separation with those of total laryngectomy. Under real-time fluoroscopy, swallowing trials were conducted using the head and neck of two Dorper cross ewes and one human cadaver, secured in lateral fluoroscopic orientation. Barium trials were administered at baseline, pre- and post-laryngohyoid suspension, following laryngotracheal separation, and following laryngectomy in the ovine model. Mean pre-intervention Penetration Aspiration Scale and National Institutes of Health Swallow Safety Scale scores were 8 ± 0 and 6 ± 0 respectively in sheep and human cadavers, with 100 per cent intra- and inter-species reproducibility. These scores improved to 1 ± 0 and 2 ± 0 post-laryngohyoid suspension (p < 0.01). Aerodigestive tract residue was 18.6 ± 2.4 ml at baseline, 15.4 ± 3.8 ml after laryngotracheal separation and 3.0 ± 0.7 ml after total laryngectomy (p < 0.001). The ovine model displayed perfect intra- and inter- species reliability for the Penetration Aspiration Scale and Swallow Safety Scale. Less aerodigestive tract residue after narrow-field laryngectomy suggests that swallowing outcomes after total laryngectomy are superior to those after laryngotracheal separation.

  13. Proteomics analyses of human optic nerve head astrocytes following biomechanical strain.

    Science.gov (United States)

    Rogers, Ronan S; Dharsee, Moyez; Ackloo, Suzanne; Sivak, Jeremy M; Flanagan, John G

    2012-02-01

    We investigate the role of glial cell activation in the human optic nerve caused by raised intraocular pressure, and their potential role in the development of glaucomatous optic neuropathy. To do this we present a proteomics study of the response of cultured, optic nerve head astrocytes to biomechanical strain, the magnitude and mode of strain based on previously published quantitative models. In this case, astrocytes were subjected to 3 and 12% stretches for either 2 h or 24 h. Proteomic methods included nano-liquid chromatography, tandem mass spectrometry, and iTRAQ labeling. Using controls for both stretch and time, a six-plex iTRAQ liquid chromatography- tandem MS (LC/MS/MS) experiment yielded 573 proteins discovered at a 95% confidence limit. The pathways included transforming growth factor β1, tumor necrosis factor, caspase 3, and tumor protein p53, which have all been implicated in the activation of astrocytes and are believed to play a role in the development of glaucomatous optic neuropathy. Confirmation of the iTRAQ analysis was performed by Western blotting of various proteins of interest including ANXA 4, GOLGA2, and αB-Crystallin.

  14. Proteomics Analyses of Human Optic Nerve Head Astrocytes Following Biomechanical Strain*

    Science.gov (United States)

    Rogers, Ronan S.; Dharsee, Moyez; Ackloo, Suzanne; Sivak, Jeremy M.; Flanagan, John G.

    2012-01-01

    We investigate the role of glial cell activation in the human optic nerve caused by raised intraocular pressure, and their potential role in the development of glaucomatous optic neuropathy. To do this we present a proteomics study of the response of cultured, optic nerve head astrocytes to biomechanical strain, the magnitude and mode of strain based on previously published quantitative models. In this case, astrocytes were subjected to 3 and 12% stretches for either 2 h or 24 h. Proteomic methods included nano-liquid chromatography, tandem mass spectrometry, and iTRAQ labeling. Using controls for both stretch and time, a six-plex iTRAQ liquid chromatography- tandem MS (LC/MS/MS) experiment yielded 573 proteins discovered at a 95% confidence limit. The pathways included transforming growth factor β1, tumor necrosis factor, caspase 3, and tumor protein p53, which have all been implicated in the activation of astrocytes and are believed to play a role in the development of glaucomatous optic neuropathy. Confirmation of the iTRAQ analysis was performed by Western blotting of various proteins of interest including ANXA 4, GOLGA2, and αB-Crystallin. PMID:22126795

  15. Canine spontaneous head and neck squamous cell carcinomas represent their human counterparts at the molecular level.

    Directory of Open Access Journals (Sweden)

    Deli Liu

    2015-06-01

    Full Text Available Spontaneous canine head and neck squamous cell carcinoma (HNSCC represents an excellent model of human HNSCC but is greatly understudied. To better understand and utilize this valuable resource, we performed a pilot study that represents its first genome-wide characterization by investigating 12 canine HNSCC cases, of which 9 are oral, via high density array comparative genomic hybridization and RNA-seq. The analyses reveal that these canine cancers recapitulate many molecular features of human HNSCC. These include analogous genomic copy number abnormality landscapes and sequence mutation patterns, recurrent alteration of known HNSCC genes and pathways (e.g., cell cycle, PI3K/AKT signaling, and comparably extensive heterogeneity. Amplification or overexpression of protein kinase genes, matrix metalloproteinase genes, and epithelial-mesenchymal transition genes TWIST1 and SNAI1 are also prominent in these canine tumors. This pilot study, along with a rapidly growing body of literature on canine cancer, reemphasizes the potential value of spontaneous canine cancers in HNSCC basic and translational research.

  16. What's the risk? Identifying potential human pathogens within grey-headed flying foxes faeces.

    Directory of Open Access Journals (Sweden)

    Rebekah Henry

    Full Text Available Pteropus poliocephalus (grey-headed flying foxes are recognised vectors for a range of potentially fatal human pathogens. However, to date research has primarily focused on viral disease carriage, overlooking bacterial pathogens, which also represent a significant human disease risk. The current study applied 16S rRNA amplicon sequencing, community analysis and a multi-tiered database OTU picking approach to identify faecal-derived zoonotic bacteria within two colonies of P. poliocephalus from Victoria, Australia. Our data show that sequences associated with Enterobacteriaceae (62.8% ± 24.7%, Pasteurellaceae (19.9% ± 25.7% and Moraxellaceae (9.4% ± 11.8% dominate flying fox faeces. Further colony specific differences in bacterial faecal colonisation patterns were also identified. In total, 34 potential pathogens, representing 15 genera, were identified. However, species level definition was only possible for Clostridium perfringens, which likely represents a low infectious risk due to the low proportion observed within the faeces and high infectious dose required for transmission. In contrast, sequences associated with other pathogenic species clusters such as Haemophilus haemolyticus-H. influenzae and Salmonella bongori-S. enterica, were present at high proportions in the faeces, and due to their relatively low infectious doses and modes of transmissions, represent a greater potential human disease risk. These analyses of the microbial community composition of Pteropus poliocephalus have significantly advanced our understanding of the potential bacterial disease risk associated with flying foxes and should direct future epidemiological and quantitative microbial risk assessments to further define the health risks presented by these animals.

  17. Head ballistocardiogram based on wireless multi-location sensors.

    Science.gov (United States)

    Onizuka, Kohei; Sodini, Charles G

    2015-08-01

    Recently a wearable BCG monitoring technique based on an accelerometer worn at the ear was demonstrated to replace a conventional bulky BCG acquisition system. In this work, a multi-location wireless vital signs monitor was developed, and at least two common acceleration vectors correlating to sitting-BCG were found in the supine position by using head PPG signal as a reference for eight healthy human subjects. The head side amplitude in the supine position is roughly proportional to the sitting amplitude that is in turn proportional to the stroke volume. Signal processing techniques to identify J-waves in a subject having small amplitude was also developed based on the two common vectors at the head side and top.

  18. Characterization of HPV and host genome interactions in primary head and neck cancers

    Science.gov (United States)

    Parfenov, Michael; Pedamallu, Chandra Sekhar; Gehlenborg, Nils; Freeman, Samuel S.; Danilova, Ludmila; Bristow, Christopher A.; Lee, Semin; Hadjipanayis, Angela G.; Ivanova, Elena V.; Wilkerson, Matthew D.; Protopopov, Alexei; Yang, Lixing; Seth, Sahil; Song, Xingzhi; Tang, Jiabin; Ren, Xiaojia; Zhang, Jianhua; Pantazi, Angeliki; Santoso, Netty; Xu, Andrew W.; Mahadeshwar, Harshad; Wheeler, David A.; Haddad, Robert I.; Jung, Joonil; Ojesina, Akinyemi I.; Issaeva, Natalia; Yarbrough, Wendell G.; Hayes, D. Neil; Grandis, Jennifer R.; El-Naggar, Adel K.; Meyerson, Matthew; Park, Peter J.; Chin, Lynda; Seidman, J. G.; Hammerman, Peter S.; Kucherlapati, Raju; Ally, Adrian; Balasundaram, Miruna; Birol, Inanc; Bowlby, Reanne; Butterfield, Yaron S.N.; Carlsen, Rebecca; Cheng, Dean; Chu, Andy; Dhalla, Noreen; Guin, Ranabir; Holt, Robert A.; Jones, Steven J.M.; Lee, Darlene; Li, Haiyan I.; Marra, Marco A.; Mayo, Michael; Moore, Richard A.; Mungall, Andrew J.; Robertson, A. Gordon; Schein, Jacqueline E.; Sipahimalani, Payal; Tam, Angela; Thiessen, Nina; Wong, Tina; Protopopov, Alexei; Santoso, Netty; Lee, Semin; Parfenov, Michael; Zhang, Jianhua; Mahadeshwar, Harshad S.; Tang, Jiabin; Ren, Xiaojia; Seth, Sahil; Haseley, Psalm; Zeng, Dong; Yang, Lixing; Xu, Andrew W.; Song, Xingzhi; Pantazi, Angeliki; Bristow, Christopher; Hadjipanayis, Angela; Seidman, Jonathan; Chin, Lynda; Park, Peter J.; Kucherlapati, Raju; Akbani, Rehan; Casasent, Tod; Liu, Wenbin; Lu, Yiling; Mills, Gordon; Motter, Thomas; Weinstein, John; Diao, Lixia; Wang, Jing; Fan, You Hong; Liu, Jinze; Wang, Kai; Auman, J. Todd; Balu, Saianand; Bodenheimer, Tom; Buda, Elizabeth; Hayes, D. Neil; Hoadley, Katherine A.; Hoyle, Alan P.; Jefferys, Stuart R.; Jones, Corbin D.; Kimes, Patrick K.; Marron, J.S.; Meng, Shaowu; Mieczkowski, Piotr A.; Mose, Lisle E.; Parker, Joel S.; Perou, Charles M.; Prins, Jan F.; Roach, Jeffrey; Shi, Yan; Simons, Janae V.; Singh, Darshan; Soloway, Mathew G.; Tan, Donghui; Veluvolu, Umadevi; Walter, Vonn; Waring, Scot; Wilkerson, Matthew D.; Wu, Junyuan; Zhao, Ni; Cherniack, Andrew D.; Hammerman, Peter S.; Tward, Aaron D.; Pedamallu, Chandra Sekhar; Saksena, Gordon; Jung, Joonil; Ojesina, Akinyemi I.; Carter, Scott L.; Zack, Travis I.; Schumacher, Steven E.; Beroukhim, Rameen; Freeman, Samuel S.; Meyerson, Matthew; Cho, Juok; Chin, Lynda; Getz, Gad; Noble, Michael S.; DiCara, Daniel; Zhang, Hailei; Heiman, David I.; Gehlenborg, Nils; Voet, Doug; Lin, Pei; Frazer, Scott; Stojanov, Petar; Liu, Yingchun; Zou, Lihua; Kim, Jaegil; Lawrence, Michael S.; Sougnez, Carrie; Lichtenstein, Lee; Cibulskis, Kristian; Lander, Eric; Gabriel, Stacey B.; Muzny, Donna; Doddapaneni, HarshaVardhan; Kovar, Christie; Reid, Jeff; Morton, Donna; Han, Yi; Hale, Walker; Chao, Hsu; Chang, Kyle; Drummond, Jennifer A.; Gibbs, Richard A.; Kakkar, Nipun; Wheeler, David; Xi, Liu; Ciriello, Giovanni; Ladanyi, Marc; Lee, William; Ramirez, Ricardo; Sander, Chris; Shen, Ronglai; Sinha, Rileen; Weinhold, Nils; Taylor, Barry S.; Aksoy, B. Arman; Dresdner, Gideon; Gao, Jianjiong; Gross, Benjamin; Jacobsen, Anders; Reva, Boris; Schultz, Nikolaus; Sumer, S. Onur; Sun, Yichao; Chan, Timothy; Morris, Luc; Stuart, Joshua; Benz, Stephen; Ng, Sam; Benz, Christopher; Yau, Christina; Baylin, Stephen B.; Cope, Leslie; Danilova, Ludmila; Herman, James G.; Bootwalla, Moiz; Maglinte, Dennis T.; Laird, Peter W.; Triche, Timothy; Weisenberger, Daniel J.; Van Den Berg, David J.; Agrawal, Nishant; Bishop, Justin; Boutros, Paul C.; Bruce, Jeff P; Byers, Lauren Averett; Califano, Joseph; Carey, Thomas E.; Chen, Zhong; Cheng, Hui; Chiosea, Simion I.; Cohen, Ezra; Diergaarde, Brenda; Egloff, Ann Marie; El-Naggar, Adel K.; Ferris, Robert L.; Frederick, Mitchell J.; Grandis, Jennifer R.; Guo, Yan; Haddad, Robert I.; Hammerman, Peter S.; Harris, Thomas; Hayes, D. Neil; Hui, Angela BY; Lee, J. Jack; Lippman, Scott M.; Liu, Fei-Fei; McHugh, Jonathan B.; Myers, Jeff; Ng, Patrick Kwok Shing; Perez-Ordonez, Bayardo; Pickering, Curtis R.; Prystowsky, Michael; Romkes, Marjorie; Saleh, Anthony D.; Sartor, Maureen A.; Seethala, Raja; Seiwert, Tanguy Y.; Si, Han; Tward, Aaron D.; Van Waes, Carter; Waggott, Daryl M.; Wiznerowicz, Maciej; Yarbrough, Wendell; Zhang, Jiexin; Zuo, Zhixiang; Burnett, Ken; Crain, Daniel; Gardner, Johanna; Lau, Kevin; Mallery, David; Morris, Scott; Paulauskis, Joseph; Penny, Robert; Shelton, Candance; Shelton, Troy; Sherman, Mark; Yena, Peggy; Black, Aaron D.; Bowen, Jay; Frick, Jessica; Gastier-Foster, Julie M.; Harper, Hollie A.; Lichtenberg, Tara M.; Ramirez, Nilsa C.; Wise, Lisa; Zmuda, Erik; Baboud, Julien; Jensen, Mark A.; Kahn, Ari B.; Pihl, Todd D.; Pot, David A.; Srinivasan, Deepak; Walton, Jessica S.; Wan, Yunhu; Burton, Robert; Davidsen, Tanja; Demchok, John A.; Eley, Greg; Ferguson, Martin L.; Shaw, Kenna R. Mills; Ozenberger, Bradley A.; Sheth, Margi; Sofia, Heidi J.; Tarnuzzer, Roy; Wang, Zhining; Yang, Liming; Zenklusen, Jean Claude; Saller, Charles; Tarvin, Katherine; Chen, Chu; Bollag, Roni; Weinberger, Paul; Golusiński, Wojciech; Golusiński, Paweł; Ibbs, Matthiew; Korski, Konstanty; Mackiewicz, Andrzej; Suchorska, Wiktoria; Szybiak, Bartosz; Wiznerowicz, Maciej; Burnett, Ken; Curley, Erin; Gardner, Johanna; Mallery, David; Penny, Robert; Shelton, Troy; Yena, Peggy; Beard, Christina; Mitchell, Colleen; Sandusky, George; Agrawal, Nishant; Ahn, Julie; Bishop, Justin; Califano, Joseph; Khan, Zubair; Bruce, Jeff P; Hui, Angela BY; Irish, Jonathan; Liu, Fei-Fei; Perez-Ordonez, Bayardo; Waldron, John; Boutros, Paul C.; Waggott, Daryl M.; Myers, Jeff; Lippman, Scott M.; Egea, Sophie; Gomez-Fernandez, Carmen; Herbert, Lynn; Bradford, Carol R.; Carey, Thomas E.; Chepeha, Douglas B.; Haddad, Andrea S.; Jones, Tamara R.; Komarck, Christine M.; Malakh, Mayya; McHugh, Jonathan B.; Moyer, Jeffrey S.; Nguyen, Ariane; Peterson, Lisa A.; Prince, Mark E.; Rozek, Laura S.; Sartor, Maureen A.; Taylor, Evan G.; Walline, Heather M.; Wolf, Gregory T.; Boice, Lori; Chera, Bhishamjit S.; Funkhouser, William K.; Gulley, Margaret L.; Hackman, Trevor G.; Hayes, D. Neil; Hayward, Michele C.; Huang, Mei; Rathmell, W. Kimryn; Salazar, Ashley H.; Shockley, William W.; Shores, Carol G.; Thorne, Leigh; Weissler, Mark C.; Wrenn, Sylvia; Zanation, Adam M.; Chiosea, Simion I.; Diergaarde, Brenda; Egloff, Ann Marie; Ferris, Robert L.; Romkes, Marjorie; Seethala, Raja; Brown, Brandee T.; Guo, Yan; Pham, Michelle; Yarbrough, Wendell G.

    2014-01-01

    Previous studies have established that a subset of head and neck tumors contains human papillomavirus (HPV) sequences and that HPV-driven head and neck cancers display distinct biological and clinical features. HPV is known to drive cancer by the actions of the E6 and E7 oncoproteins, but the molecular architecture of HPV infection and its interaction with the host genome in head and neck cancers have not been comprehensively described. We profiled a cohort of 279 head and neck cancers with next generation RNA and DNA sequencing and show that 35 (12.5%) tumors displayed evidence of high-risk HPV types 16, 33, or 35. Twenty-five cases had integration of the viral genome into one or more locations in the human genome with statistical enrichment for genic regions. Integrations had a marked impact on the human genome and were associated with alterations in DNA copy number, mRNA transcript abundance and splicing, and both inter- and intrachromosomal rearrangements. Many of these events involved genes with documented roles in cancer. Cancers with integrated vs. nonintegrated HPV displayed different patterns of DNA methylation and both human and viral gene expressions. Together, these data provide insight into the mechanisms by which HPV interacts with the human genome beyond expression of viral oncoproteins and suggest that specific integration events are an integral component of viral oncogenesis. PMID:25313082

  19. Targeting ADAM12 in human disease: head, body or tail?

    DEFF Research Database (Denmark)

    Jacobsen, J; Wewer, U M

    2009-01-01

    ) and insulin-like growth factor receptor signaling. The body of the protein (consisting of the disintegrin, cysteine-rich, and EGF-like domains) is involved in contacts with the extracellular matrix and other cells through interactions with integrins and syndecans. Finally, the tail of the protein (consisting......ADAM12/meltrin alpha is a type I transmembrane multidomain protein involved in tumor progression and other severe diseases, including osteoarthritis, and as such could be considered as a potential drug target. In addition to protease activity, ADAM12 possesses cell binding and cell signaling...... properties. This functional trinity is reflected in the structure of ADAM12, which can be divided into head, body, and tail. The head of the protein (consisting of the pro and catalytic domains) mediates processing of growth factors and cytokines and has been implicated in epidermal growth factor (EGF...

  20. Characterizing occipital condyle loads under high-speed head rotation.

    Science.gov (United States)

    Pintar, Frank A; Yoganandan, Narayan; Baisden, Jamie

    2005-11-01

    Because of the need to evaluate anthropomorphic test device (ATD) biofidelity under high-head angular accelerations, the purpose of the present investigation was to develop appropriate instrumentation for intact post mortem human subject (PMHS) testing, validate the instrumentation, and obtain information to characterize the response of the head-neck complex under this loading scenario. A series of rigid-arm pendulum, inertially loaded ATD tests was conducted. Head and neck ATD hydraulic piston chin pull tests were conducted. Subsequently, a series of PMHS tests was conducted to derive the response of the human head-neck under high-rate chin loading. Finally, Hybrid III and THOR-NT ATD head-neck systems were evaluated under the same scenario as the PMHS. A parametric analysis for center of gravity (CG) location and accelerometer orientation determined that even small errors (+/- 3 mm or 2 degrees), produced errors in the force and moment calculations by as much as 17 %. If the moment of inertia (MOI) term was varied by 5 %, resulting moment calculations were affected by as much as 8 %. If the 5 % error in MOI was used to compute occipital condyle moments, and results compared to upper load cell derived moments, peaks differed by as much as 24 %. The head CG and mass MOI should be directly measured for each preparation to obtain accurate results. The injury run on each specimen resulted in predominantly C1-C2 separations or partial separations. The 50(th) percentile probability of AIS=2+ neck injury using tensile force was about 2400 N; for AIS=3+ neck injury the 50(th) percentile risk was about 3180 N. When inserting extension moment as the criteria, the 50(th) percentile probability of an AIS=2+ injury was 51 Nm. The AIS=3+ extension moment at the 50(th) percentile probability was 75 Nm. The new THOR-NT ATD head-neck produced more biofidelic responses with an alternate head-neck junction design compared to the Hybrid III ATD.