WorldWideScience

Sample records for hpd devices

  1. Software of the control computer of HPD scanning device

    International Nuclear Information System (INIS)

    Belyaev, A.V.; Rubtsov, V.F.; Slepnev, S.K.; Susov, Yu.I.

    1979-01-01

    Specific features of HPD measuring system are considered which are important for TPA-1001i computer programming, being the control computer of scanning device. The instruction language intended for interacting the computer with HPD electronics is given. Resident, auxiliary and test subprograms including those for interrupt handling, for monitoring, a driver for the operation with a teletype, a loader, a cross-assembler are described

  2. Design and qualification of HPD based designs for safety systems

    International Nuclear Information System (INIS)

    Sharma, Mukesh Kr.; Chavan, Madhavi A.; Sawhney, Pratibha A.; Mohanty, Ashutos; John, Ajith K.; Ganesh, G.

    2014-01-01

    Field Programmable Gate Arrays (FPGA) and Complex Programmable Logic Devices (CPLD) are increasingly being used in C and I system of NPPs. The function of such an integrated circuit is not defined by the supplier of the physical component or micro-electronic technology but by the C and I designer. The hardware subsystems implemented in these devices typically use Hardware Description Language (HDL) like VHDL or Verilog to describe the functionality at the design entry level. These circuits are commonly known as 'HDL-Programmed Devices', (HPD). RCnD has developed a set of hardware boards to be used in next generation C and I systems. The boards have been designed based on present day technology and components. The intelligence of these boards has been implemented in HPDs (FPGA/CPLD) using VHDL. Since these boards are used in the safety and safety related systems, they have undergone a rigorous V and V process and qualification tests. This paper discusses the design attributes and qualification of these HPD based designs for nuclear class safety systems. (author)

  3. Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

    CERN Multimedia

    Maximilien Brice

    2004-01-01

    Two members of the CERN HPD team present their babies. André Braem (left) holds in his hands a 5-inch glass HPD, while a ceramic HPD for medical applications is shown by Christian Joram. The large detector in the middle is a 10-inch HPD developed for an astrophysics experiment.

  4. The early history of the HPD

    International Nuclear Information System (INIS)

    Powell, B.

    1994-01-01

    The initial stages of the development of a system for the rapid measurement of bubble chamber photographs are described. At first called the IEP-X and then IEP-Y, the device which came to be known as the HPD was adopted by several groups both in Europe and the USA. Based on a mechanically generated flying spot, it was the first machine to use this technique for bubble chamber film measurement. Operated in the ''road guidance'' mode, it provided considerable measurement capacity combined with excellent precision and very acceptable bubble density measurements. ((orig.))

  5. Scintillator studies for the HPD-PET concept

    CERN Document Server

    Braem, D; Ciocia, F; De Leo, R; Joram, C; Lagamba, L; Nappi, E; Séguinot, Jacques; Vilardi, I; Weilhammer, P

    2007-01-01

    The spatial, energy, and time resolutions of 10 cm long polished YAP:Ce and LYSO:Ce crystals have been measured. The work is part of the novel HPD-PET concept, based on a full three-dimensional, free of parallax errors, reconstruction of the γ-ray interaction point in 10–15 cm long scintillators. The effective light attenuation length, a key parameter of the HPD-PET concept, and the resolutions have been measured for various wrappings and coatings of the crystal lateral surfaces. Even if the final HPD-PET prototype could use scintillators and/or wrappings different from those tested, the results here presented prove the feasibility of the concept and provide hints on its potential capabilities.

  6. Development of a 10-inch HPD with integrated readout electronics

    CERN Document Server

    Braem, André; Joram, C; Séguinot, Jacques; Weilhammer, Peter; Giunta, M; Malakhov, N; Menzione, A; Pegna, R; Piccioli, A; Raffaelli, F; Sartori, G

    2003-01-01

    A round 10-in. diameter Hybrid Photodiode (HPD) with spherical entrance window is under development for Cherenkov imaging applications in cosmic ray astronomy. The HPD adopts the fountain focusing electron optics, which, as already demonstrated in the 5 inch Pad HPD, allows for a linear demagnification of the image over practically the full tube diameter. Self-triggering front-end electronics providing also sparse readout capability, has been tested. High-efficiency Rb//2Te cathodes have been produced on a UV extended borosilicate glass windows with very thin conductive underlayers of Indium Tin Oxide. We report on the design of the 10- in. HPD, the fabrication procedure and first tests of a 5-in. HPD with Rb//2Te photocathode and 2048 channels.

  7. Hourly Precipitation Data (HPD) Publication

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Hourly Precipitation Data (HPD) Publication is archived and available from the National Climatic Data Center (NCDC). This publication contains hourly precipitation...

  8. HPD application for film processing from the BEBC bubble chamber at IHEP

    International Nuclear Information System (INIS)

    Borovikov, A.A.; Bryzgalov, V.V.; Gritsaenko, I.A.; Gubaeva, M.M.; Gumenyuk, S.A.; Zajtsev, L.F.; Petrovykh, Yu.L.; Khromova, G.N.; Fenyuk, A.B.

    1982-01-01

    The capabilities and advantages of using HPD for processing of the films from the big hydrogen bubble chamber BEBC for K + p 70 GeV/c experiment are described. Some characteristics of operational features of HPD system are presented. The HPD accuracy of pressed crossing measurements constitutes from 0.75 to 2.75 μm, and chamber crossing - from 6.5 to 13.0 μm [ru

  9. Design, fabrication and performance of the 10-in TOM HPD

    CERN Document Server

    Braem, André; Joram, C; Séguinot, Jacques; Weilhammer, P; Giunta, M; Malakhov, N; Menzione, A; Pegna, R; Piccioli, A; Raffaelli, F; Sartori, G

    2004-01-01

    The first sealed TOM Hybrid Photon Detector (HPD) with 10-in. diameter has been fabricated and successfully tested at CERN. This HPD has a spherical entrance window and a bialkali photocathode. The fountain focusing optics produces a demagnified image (D = 4) on the round segmented silicon sensor. The signals of the 2048 cells are read out through analog front-end electronics encapsulated in the vacuum envelope. We report on the design, fabrication technique and the experimental results obtained with laboratory test benches. The large TOM HPD is a prototype tube developed for the CLUE cosmic ray experiment. The final tubes, now under development, will be equipped with a solar-blind Rb//2Te photocathode and self triggering front-end electronics.

  10. Design, fabrication and performance of the 10-in. TOM HPD

    International Nuclear Information System (INIS)

    Braem, A.; Chesi, E.; Joram, C.; Seguinot, J.; Weilhammer, P.; Giunta, M.; Malakhov, N.; Menzione, A.; Pegna, R.; Piccioli, A.; Raffaelli, F.; Sartori, G.

    2004-01-01

    The first sealed TOM Hybrid Photon Detector (HPD) with 10-in. diameter has been fabricated and successfully tested at CERN. This HPD has a spherical entrance window and a bialkali photocathode. The fountain focusing optics produces a demagnified image (D=4) on the round segmented silicon sensor. The signals of the 2048 cells are read out through analog front-end electronics encapsulated in the vacuum envelope. We report on the design, fabrication technique and the experimental results obtained with laboratory test benches. The large TOM HPD is a prototype tube developed for the CLUE cosmic ray experiment. The final tubes, now under development, will be equipped with a solar-blind Rb 2 Te photocathode and self triggering front-end electronics

  11. Extensive tests of Hybrid Photon Detectors (HPD) used to collect Cherenkov light

    International Nuclear Information System (INIS)

    Borsato, E.; Buccheri, A.; DalCorso, F.; Ferroni, F.; Iacovella, F.; Mazzoni, M.A.; Morandin, M.; Morganti, S.; Piredda, G.; Posocco, M.; Santacesaria, R.; Stroili, R.; Torassa, E.; Voci, C.

    1997-01-01

    The principle of operation of a newly developed proximity focused Hybrid Photon Detector is described. The HPD characteristics, performance and calibration are reported. Results from beam tests of aerogel threshold counters read out by HPD and the particle identification performance are presented. (orig.)

  12. Review of the hybrid photo diode tube (HPD) an advanced light detector for physics

    International Nuclear Information System (INIS)

    Anzivino, G.; Baillon, P.; Benetti, P.; Boskma, L.; Burger, P.; Contin, A.; DeSalvo, R.; Gorodetzky, P.; Grassi, D.; Hao, W.; He, H.; Liu, L.; Lundin, M.; Mondardini, M.R.; Paolucci, S.; Rossella, M.; Santiard, J.C.; Schomaker, R.; You, K.; Wang, K.; Wang, Y.; Xia, X.; Xu, C.; Yang, C.; Zhao, M.

    1995-01-01

    The HPD is a nonmultiplicative light detector with typical gain of 1000 to 5000. Its development project, mainly supported by the CERN LAA project and by the INFN group V, was originally intended to find a replacement for the photo multiplier (PM) tubes for scintillating fibre calorimeter readout. After five years of development the HPD has become a versatile light detector, commercially available for everyday use, that can outperform PM tubes in photon counting efficiency and resolution, multi tesla magnetic field operation, uniformity of response, fast pulse dynamic range, and gain stability. The HPD has also a wide edge on PMs on pixelization potential and it is getting more and more competitive on timing properties. A review of the HPD performances and its latest advances are reported. (orig.)

  13. Review of the hybrid photo diode tube (HPD) an advanced light detector for physics

    Energy Technology Data Exchange (ETDEWEB)

    Anzivino, G. [Istituto Nazionale di Fisica Nucleare, Frascati (Italy). Lab. Nazionale di Frascati; Arnaudon, H. [Universite` L. Pasteur, 4, rue B. Pascal, F-67000 Strasbourg (France); Baillon, P. [CERN, CH-1211 Geneva 23 (Switzerland); Benetti, P. [INFN Sezione di Pavia and Universita` di Pavia, via A. Bassi 6, I-27100 Pavia (Italy); Boskma, L. [DEP, P.O. box 60, NL-9300 AB Roden (Netherlands); Burger, P. [Canberra, Lammerdries 25, B-2250 Olen (Belgium); Contin, A. [CERN, CH-1211 Geneva 23 (Switzerland)]|[INFN Sezione di Bologna and Universita` di Bologna, via Irnerio 46, I-40126 Bologna (Italy); DeSalvo, R. [CERN, CH-1211 Geneva 23 (Switzerland); Gorodetzky, P. [CNRS, Strasbourg (France); Grassi, D. [INFN Sezione di Pavia and Universita` di Pavia, via A. Bassi 6, I-27100 Pavia (Italy); Hao, W. [IHEP, Beijing (China); He, H. [IHEP, Beijing (China); Liu, L. [IHEP, Beijing (China); Lundin, M. [Cornell University, Ithaca, NY 14853 (United States); Mondardini, M.R. [Cornell University, Ithaca, NY 14853 (United States); Paolucci, S. [INFN Sezione di Pavia and Universita` di Pavia, via A. Bassi 6, I-27100 Pavia (Italy); Rossella, M. [INFN Sezione di Pavia and Universita` di Pavia, via A. Bassi 6, I-27100 Pavia (Italy); Santiard, J.C. [CERN, CH-1211 Geneva 23 (Switzerland); Schomaker, R. [DEP, P.O. box 60, NL-9300 AB Roden (Netherlands); You, K. [IHEP, Beijing (China); Wang, K. [IHEP, Beijing (China); Wang, Y. [IHEP, Beijing (China); Xia, X. [IHEP, Beijing (China); Xu, C. [IHEP, Beijing (China); Yang, C. [IHEP, Beijing (China); Zhao, M. [IHEP, Beijing (China)

    1995-11-01

    The HPD is a nonmultiplicative light detector with typical gain of 1000 to 5000. Its development project, mainly supported by the CERN LAA project and by the INFN group V, was originally intended to find a replacement for the photo multiplier (PM) tubes for scintillating fibre calorimeter readout. After five years of development the HPD has become a versatile light detector, commercially available for everyday use, that can outperform PM tubes in photon counting efficiency and resolution, multi tesla magnetic field operation, uniformity of response, fast pulse dynamic range, and gain stability. The HPD has also a wide edge on PMs on pixelization potential and it is getting more and more competitive on timing properties. A review of the HPD performances and its latest advances are reported. (orig.).

  14. Bubble chamber film exposure for measurement by HPD

    International Nuclear Information System (INIS)

    Oxley, A.J.

    1978-03-01

    It is not easy for HPD measuring machines to detect tracks of low contrast in film from bubble chambers with bright-field illumination. Some of the basic aspects and limitations are considered in this paper. (author)

  15. A large spherical HPD for a novel deep-sea neutrino experiment

    International Nuclear Information System (INIS)

    Ball, A.E.; Braem, A.; Camilleri, L.; Catinaccio, A.; Chelkov, G.; Dydak, F.; Elagin, A.; Frandsen, P.; Grant, A.; Gostkin, M.; Guskov, A.; Joram, C.; Krumshteyn, Z.; Lustermann, W.; Postema, H.; Price, M.; Rovelli, T.; Schinzel, D.; Seguinot, J.; Valenti, G.; Voss, R.; Wotschack, J.; Zhemchugov, A.

    2005-01-01

    An underwater neutrino experiment has been proposed which provides precise measurements of the neutrino mixing parameters θ 23 and Δm 23 2 and permits an increase of sensitivity for the small angle θ 13 by more than one order of magnitude. A Cherenkov detector of about 1.5Mt active mass, deployed in the Gulf of Taranto, utilizes the CNGS beam in off-axis configuration which represents an essentially mono-energetic source of muon neutrinos. A unique feature of the experiment is the possibility to move the detector and therefore exploit different baselines around 1200km where the oscillation pattern is fully developed. The conceptual detector design consists of O(30,000) large area and acceptance photosensors arranged in a matrix of ∼300x300m 2 size. Hybrid photon detectors are considered as promising candidates as they provide clean signal characteristics and uniform collection efficiency. We discuss the design and expected performance of a large spherical HPD with 380mm diameter, which is housed in a high-pressure glass container. A scaled prototype HPD of 208mm diameter is currently under development using the existing CERN HPD facility

  16. Design, fabrication and characterization of an 8-in. X-HPD

    CERN Document Server

    Braem, André; Séguinot, Jacques; Solevi, Paola; Dehaine, Anne-Gaelle

    2009-01-01

    The X-HPD is a modern implementation of the hybrid concept first employed by the Philips SMART and the QUASAR tubes of the Lake Baikal experiment, aiming at improved performance and maximum simplicity. The glass envelope is essentially spherical and a spatial scintillator crystal is mounted in its center. Photoelectrons from the cathode are accelerated by a potential difference of 20–30 kV and deposit their kinetic energy in the scintillator (or Phosphor). The generated scintillation light is detected by a small and low cost photodetector, e.g. a conventional PMT. The spherical symmetry leads to a uniform collection efficiency and very small intrinsic time spread over the full viewing angle of 120 (3π solid angle). We report about the design, fabrication and test results of a first X-HPD prototype of 208 mm diameter with a conical LYSO crystal anode. Monte Carlo studies with Geant4 led to a qualitative understanding of the light transport in the anode assembly.

  17. The X-HPD-A modern implementation of a SMART concept

    International Nuclear Information System (INIS)

    Braem, Andre; Joram, Christian; Seguinot, Jacques; Solevi, Paola; Pierre, Leo

    2009-01-01

    The concept of hybrid photodetectors which combine a large area photocathode with a crystal scintillator anode in the centre of a hemispherical vacuum tube was demonstrated first with the Philips SMART tubes and, more recently, with the QUASAR tubes of the Lake Baikal experiment. Photoelectrons from the cathode are accelerated by a potential difference of 20-30 kV and deposit their kinetic energy in the scintillator (or Phosphor). The generated scintillation light is detected by a small and low cost photodetector, e.g. a conventional PMT. The X-HPD study is a variation of this concept aiming at improved performance and maximum simplicity. The glass envelope is essentially spherical and a spatial scintillator crystal is mounted in its centre. The spherical symmetry leads to a uniform collection efficiency and very small intrinsic time spread over the full viewing angle of 120 deg. (3π solid angle). We report about test results of a the first X-HPD prototypes of 208 mm diameter with cylindrical and conical LYSO crystal anodes.

  18. Usefulness of the protection motivation theory in explaining hearing protection device use among male industrial workers.

    Science.gov (United States)

    Melamed, S; Rabinowitz, S; Feiner, M; Weisberg, E; Ribak, J

    1996-05-01

    The present study examined the usefulness of personal variables: noise annoyance, and components of the protection motivation theory (R. W. Rogers, 1983) along with social-organizational factors in explaining hearing protection device (HPD) use among Israeli manufacturing workers. Participants were 281 men exposed to harmful noise levels for which routine HPD use is required by regulation. In practice, 3 HPD user groups were identified: nonusers (n = 38), occasional users (n = 125), and regular users (n = 118). HPD use was objectively verified. HPD use was primarily related to the personal variables but not to management pressure, coworker pressure, or family support. The most powerful predictors of HPD use were perceived self-efficacy (for long-term HPD use), perceived susceptibility (to hearing loss), and noise annoyance, together explaining 48% of the outcome variance. These findings have implications for interventions aimed at motivating workers to use HPDs regularly.

  19. Measurement of the Photoelectron Detection Efficiency of the HPD Anode

    CERN Document Server

    Carson, L; Soler, P

    2009-01-01

    This paper reports on measurements carried out on the Hybrid Photon Detectors (HPDs) of the LHCb RICH detectors. The purpose of these tests is to determine the photoelectron detection efficiency $\\eta$ of the HPD anode. Knowledge of $\\eta$ is required for an accurate simulation of the RICH detectors. It is found that this efficiency is $(93.3\\pm0.7)\\%$ for a 50 ns digital readout window, and $(87.9\\pm1.4)\\%$ for a 25 ns digital readout window. The 25 ns result exceeds the LHCb-RICH requirement of 85\\%, and is in agreement both with direct $\\eta$ measurements using preseries HPDs, and with indirect measurements from testbeams using preseries and production HPDs.

  20. Gender differences in use of hearing protection devices among farm operators

    Directory of Open Access Journals (Sweden)

    Marjorie C McCullagh

    2016-01-01

    Full Text Available Purpose: Although farm operators have frequent exposure to hazardous noise and high rates of noise-induced hearing loss, they have low use of hearing protection devices (HPDs. Women represent about one-third of farm operators, and their numbers are climbing. However, among published studies examining use of HPDs in this worker group, none have examined gender-related differences. The purpose of this study was to examine gender-related differences in use of hearing protection and related predictors among farm operators. Materials and Methods: Data previously collected at farm shows and by telephone were analyzed using t-tests and generalized linear model with zero inflated negative binomial (ZINB distribution. Findings: The difference in rate of hearing protector use between men and women farm operators was not significant. There was no difference between men and women in most hearing protector-related attitudes and beliefs. Conclusion: Although men and women farm operators had similar rates of use of hearing protectors when working in high-noise environments, attitudes about HPD use differed. Specifically, interpersonal role modeling was a predictor of HPD use among women, but not for men. This difference suggests that while farm operators of both genders may benefit from interventions designed to reduce barriers to HPD use (e.g., difficulty communicating with co-workers and hearing warning sounds, farm women have unique needs in relation to cognitive-perceptual factors that predict HPD use. Women farm operators may lack role models for use of HPDs (e.g., in peers and advertising, contributing to their less frequent use of protection.

  1. Towards an Active Hearing Protection Device for Musicians =

    Science.gov (United States)

    Bernier, Antoine

    Professional musicians are oftentimes exposed to high levels of sound. Prolonged or severe exposure to high sound levels could lead to permanent hearing loss and compromise their career. The logical solution would be to wear hearing protection devices (HPDs) when appropriate. However, perceptual discomfort associated with wearing HPD can discourage their use by musicians. The perceptual discomfort is caused by two detrimental effects: the occlusion effect and the isolation effect. The occlusion effect is often reported as an augmented, unnatural and annoying perception of one's own voice or instrument mechanically coupled to the head when wearing HPDs. The isolation effect is the unnatural sensation of being isolated from a given sound environment and can be caused by wearing HPDs that do not compensate for psychoacoustical factors and therefore alter the wearer's auditory perception. Both effects are highly unfavorable to the musicians' auditory perception and compromise their capacity to perform to the best of their abilities for their audience. They are among the reasons most often reported by musicians to decide not to wear HPDs. This master's project presents the concept and first prototype of an active HPD for musicians that aims at solving the detrimental effects while protecting the musician's hearing. A solution for the occlusion effect is presented in the form of an earplug complemented with in-ear active noise control. Practical design issues and required trade-off are analyzed through a literature review and the implementation and characterization of an active occlusion effect reduction system, allowing reduction of the occlusion effect between 8.5 and 12 dB at 250 Hz. A solution for the isolation effect is presented in the form of an earplug complemented with digital signal processing capabilities. Factors that may cause the isolation effect are identified through a literature review and corresponding algorithms that aim at re-establishing the

  2. Evaluation of personal dose equivalent 'HP(d)' in a external individual monitoring system for X and gamma radiation

    International Nuclear Information System (INIS)

    Santoro, C.; Antonio Filho, J.; Santos, M.A.P.

    2007-01-01

    The good of individual monitoring for external radiation is the assessment of occupational exposure from X and γ radiations in order to assure that the radiological conditions of the workplace are acceptable, safe and satisfactory. The evaluation of radiations doses for workers must not exceed dose limits specified for workers, according to national regulatory agencies. Nowadays, there are two external monitoring systems in use, both based on ICRU definitions. In the conventional system, the workers doses are evaluated in terms of Hx. The personal dosimeter is worn over chest surface and it is calibrated in function of air kerma. In the new system, the workers doses are evaluated in terms of HP(d) and the personal dosimeter is calibrated in function of phantom doses. The aim of this paper is to adapt an external dosimetry laboratory (based on photographic dosimetry) to evaluate the personal dosimeters in terms of HP(d). In this way, a simple methodology, based on linear programming, was utilized. In this adaptation, calibration curves were obtained for radiation qualities (W and N series) described by International Organization for Standardization (ISO 4037-1, 1995). These calibration curves offer a better accuracy on dose determinations and energy below 140 keV, improving the quality of service rendered the society. (author)

  3. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    Science.gov (United States)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen; Falk, Tiago H.; Voix, Jérémie

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12 different talkers at 5 different distances in 3…

  4. An overview of review guidelines for HDL programmable devices in nuclear safety systems

    International Nuclear Information System (INIS)

    Komanduri, Raghavan; Srivani, L.; Thirugnana Murthy, D.

    2013-01-01

    HDL programmable devices viz. CPLDs and FPGAs are increasingly being used to implement digital designs in the I and C systems performing safety functions of nuclear power plants. Synthesizable RTL descriptions manually written in HDLs are the first step in developing industry standard large scale digital designs. The reliability of the implementation is determined by the methodologies followed by the designer during development. Very few guidelines on HPD design practices, specific to nuclear industry are available. This paper presents an overview of the existing guidelines such as IEC 62566 and U.S. NRC's 'Review guidelines for FPGAs in nuclear power plant safety systems'. (author)

  5. Predictors of Hearing Protection Use Among Industrial Workers.

    Science.gov (United States)

    Tantranont, Kunlayanee; Codchanak, Nuntanat

    2017-08-01

    Promoting the use of hearing protection devices (HPDs) can prevent noise-induced hearing loss (NIHL) among workers who are exposed to excessive noise. In the present study, the authors examine factors that may explain HPD use among industrial workers from 15 manufacturing plants in Thailand. Participants consisted of 268 randomly selected workers exposed to harmful noise levels for which routine HPD use was required. Logistic regression analysis of study variables revealed the most powerful predictors of HPD use were perceived hearing status ( b = 0.66, p workers to use HPDs regularly.

  6. Modeling Speech Level as a Function of Background Noise Level and Talker-to-Listener Distance for Talkers Wearing Hearing Protection Devices

    DEFF Research Database (Denmark)

    Bouserhal, Rachel E.; Bockstael, Annelies; MacDonald, Ewen

    2017-01-01

    Purpose: Studying the variations in speech levels with changing background noise level and talker-to-listener distance for talkers wearing hearing protection devices (HPDs) can aid in understanding communication in background noise. Method: Speech was recorded using an intra-aural HPD from 12...... complements the existing model presented by Pelegrín-García, Smits, Brunskog, and Jeong (2011) and expands on it by taking into account the effects of occlusion and background noise level on changes in speech sound level. Conclusions: Three models of the relationship between vocal effort, background noise...

  7. Hearing Health in College Instrumental Musicians and Prevention of Hearing Loss.

    Science.gov (United States)

    Olson, Anna D; Gooding, Lori F; Shikoh, Fara; Graf, Julie

    2016-03-01

    College musicians exhibit greater declines in hearing than the general population and are at particular risk because they rehearse and perform daily in loud environments. Also, they engage in use of personal listening devices which increases the amount of "exposure" time. Despite increased risk, many do not use hearing protection devices (HPD). The purpose of this study was to (1) to identify the present level of education about hearing health, (2) identify the perceived advantages and disadvantages of using HPD, and (3) evaluate results among different musical instrument groups. A mixed-methods group design was used including both quantitative and qualitative instruments. SPSS was used to generate descriptive statistics, and non-parametric statistical analysis was performed on quantitative data. NVivo software was used to evaluate qualitative responses. Of the 90 college instrumental music students who participated, 12% reported a history of hearing loss, and over one-third reported tinnitus. Seventy-seven percent of participants had never received any training about hearing health and only a small percentage of students used HPD. The most cited reason for lack of protection use was its negative impact on sound quality. However, group differences were noted between brass, woodwind, and percussion musicians in terms of HPD uptake. Improving the type of information disseminated to college musicians may reduce the risk of ear-related deficits. Noise dosage information, HPD information, and prevention education grounded in theories like the Health Belief Model may increase awareness and promote greater use of HPDs in this population.

  8. Performance Studies of Pixel Hybrid Photon Detectors for the LHCb RICH Counters

    CERN Document Server

    Aglieri Rinella, G; Piedigrossi, D; Van Lysebetten, A

    2004-01-01

    The Pixel Hybrid Photon Detector is a vacuum tube with a multi-alkali photo cathode, high voltage cross-focused electron optics and an anode consisting of a silicon pixel detector bump-bonded to a readout CMOS electronic chip fully encapsulated in the device. The Pixel HPD fulfils the requirements of the Ring Imaging Cherenkov counters of the LHCb experiment at LHC. The performances of the Pixel HPD will be discussed with reference to laboratory measurements, Cherenkov light imaging in recent beam tests, image distortions due to a magnetic field.

  9. Noise-Induced Hearing Loss - A Preventable Disease?

    DEFF Research Database (Denmark)

    Frederiksen, Thomas W.; Ramlau-Hansen, Cecilia H.; Stokholm, Zara A.

    2017-01-01

    AIMS: To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD) over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and...

  10. Development of heat pump and infrared-convective dryer and performance analysis for stale bread drying

    International Nuclear Information System (INIS)

    Aktaş, Mustafa; Şevik, Seyfi; Aktekeli, Burak

    2016-01-01

    Highlights: • Investigation of stale bread drying behaviors by developing the HPD and IRD. • New techniques for the HP and IR dryers are proposed and found to be efficient. • Evaluations on potential uses low temperature applications of the dryers were reported. • 35.6% of energy saving was provided by heat recovery device. • The overall system efficiency of HPD was calculated as 13–60%. - Abstract: This experimental study aims to develop a heat pump dryer (HPD) and an infrared dryer (IRD) also the comparative empirical analyses of these two methods and to analyze the drying kinetic of stale bread sliced 15 mm thickness and effectiveness on the drying kinetics of the stale bread of dryers. Dryers have been developed by using different techniques such as heat recovery unit, proportional control (PC) of drying air temperature, simultaneous control of the relative humidity–temperature–air flow rate, water cycle dehumidifier and closed-loop cycle to increase the drying efficiency of industrial drying applications. The highest coefficient of performance of the whole heat pump system (COP_w_s_,_H_P) was calculated as 3.7 and drying efficiencies of the IRD and HPD systems were calculated as 39% and 25%, respectively. When the HPD and IRD systems were compared in terms of drying time and energy consumption, it was observed that the IRD system did not only shortened the drying time up to 69%, but also decreased the energy consumption of the system by 43.2%. Based on the obtained results the effective moisture diffusivity (D_e) was calculated in the range from 8.3 × 10"−"8 to 3.2 × 10"−"7 m"2/s and mass transfer coefficient (h_m) was varied from 1.17 × 10"−"5 to 4.52 × 10"−"5 m/s. It was concluded that both dryers have significant effect in reduction of water content; the relative humidity controlled HPD can be applied efficiently for dryers and the dried stale bread can be reused as bread crumb by food industry.

  11. Computational Environments and Analysis methods available on the NCI High Performance Computing (HPC) and High Performance Data (HPD) Platform

    Science.gov (United States)

    Evans, B. J. K.; Foster, C.; Minchin, S. A.; Pugh, T.; Lewis, A.; Wyborn, L. A.; Evans, B. J.; Uhlherr, A.

    2014-12-01

    The National Computational Infrastructure (NCI) has established a powerful in-situ computational environment to enable both high performance computing and data-intensive science across a wide spectrum of national environmental data collections - in particular climate, observational data and geoscientific assets. This paper examines 1) the computational environments that supports the modelling and data processing pipelines, 2) the analysis environments and methods to support data analysis, and 3) the progress in addressing harmonisation of the underlying data collections for future transdisciplinary research that enable accurate climate projections. NCI makes available 10+ PB major data collections from both the government and research sectors based on six themes: 1) weather, climate, and earth system science model simulations, 2) marine and earth observations, 3) geosciences, 4) terrestrial ecosystems, 5) water and hydrology, and 6) astronomy, social and biosciences. Collectively they span the lithosphere, crust, biosphere, hydrosphere, troposphere, and stratosphere. The data is largely sourced from NCI's partners (which include the custodians of many of the national scientific records), major research communities, and collaborating overseas organisations. The data is accessible within an integrated HPC-HPD environment - a 1.2 PFlop supercomputer (Raijin), a HPC class 3000 core OpenStack cloud system and several highly connected large scale and high-bandwidth Lustre filesystems. This computational environment supports a catalogue of integrated reusable software and workflows from earth system and ecosystem modelling, weather research, satellite and other observed data processing and analysis. To enable transdisciplinary research on this scale, data needs to be harmonised so that researchers can readily apply techniques and software across the corpus of data available and not be constrained to work within artificial disciplinary boundaries. Future challenges will

  12. Photobiology of porphyrins

    International Nuclear Information System (INIS)

    Gomer, C.J.

    1984-01-01

    Hematoporphyrin derivative (HpD) photoradiation therapy (PRT) continues to show promise as a modality for the treatment of certain solid tumors. However, there are still numerous photobiological parameters pertaining to HpD PRT which are not fully defined. This presentation describes preclinical studies performed to examine the efficacy of HpD PRT for the treatment of ocular tumors. In addition, results of photobiological experiments designed to define the action spectrum characteristics, light dose rate properties and mutagenic potential of HpD PRT are discussed. Preclinical studies have examined the pharmacology of HpD and the toxicology of HpD PRT in both normal and malignant structures in the eye of pigmented rabbits. Distribution of HpD was measured by an acid extraction procedure. Vascular structures of the eye such as the choroid, iris and the experimental tumor retained significant levels of HpD following I.V. administration. Non-vascular structures such as cornea and lens did not take up HpD. Toxicity studies demonstrated that HpD administration (1-10 mg/kg) followed 48 hr later with a transpupil irradiation of red light (630 nm, 40-90 J/cm/sup 2/) resulted in well defined areas of retinal damage within the treatment field. The lenses of 18 eyes have remained clear during a 24 month follow-up. Tumor response following HpD PRT is rapid and is characterized by massive vascular disruption and tumor tissue necrosis

  13. Effects of Active and Passive Hearing Protection Devices on Sound Source Localization, Speech Recognition, and Tone Detection.

    Directory of Open Access Journals (Sweden)

    Andrew D Brown

    Full Text Available Hearing protection devices (HPDs such as earplugs offer to mitigate noise exposure and reduce the incidence of hearing loss among persons frequently exposed to intense sound. However, distortions of spatial acoustic information and reduced audibility of low-intensity sounds caused by many existing HPDs can make their use untenable in high-risk (e.g., military or law enforcement environments where auditory situational awareness is imperative. Here we assessed (1 sound source localization accuracy using a head-turning paradigm, (2 speech-in-noise recognition using a modified version of the QuickSIN test, and (3 tone detection thresholds using a two-alternative forced-choice task. Subjects were 10 young normal-hearing males. Four different HPDs were tested (two active, two passive, including two new and previously untested devices. Relative to unoccluded (control performance, all tested HPDs significantly degraded performance across tasks, although one active HPD slightly improved high-frequency tone detection thresholds and did not degrade speech recognition. Behavioral data were examined with respect to head-related transfer functions measured using a binaural manikin with and without tested HPDs in place. Data reinforce previous reports that HPDs significantly compromise a variety of auditory perceptual facilities, particularly sound localization due to distortions of high-frequency spectral cues that are important for the avoidance of front-back confusions.

  14. In vivo distribution of Mn-hematoporphyrin derivative in tumor bearing mice54

    International Nuclear Information System (INIS)

    Crone Escanye, M.C.; Anghilleri, L.T.; Robert, J.

    1988-01-01

    This paper presents results of preliminary studies of the in vivo uptake and biodistribution of manganese labbelled hematoporphyrin derivative (HpD). The results indicate that: (1) Mn-HpD 54 is crhomatographically very similar to HpD; (2) the tissue distribution of Mn-HpD 54 are overal compareble to that reported by other. Authors for C 14 -HpD and H 3 -HpD in tumor bearing mice. It seems therefore that maanganese labelled HpD for the non invasivequantitation of HpD concetration in tumor and normal tissues and may be hepful in assessing the potential usefulness of Mn-HpD in NMR imaging of living animals

  15. Prevalence and predictors of hair pulling disorder and excoriation disorder in Tourette syndrome.

    Science.gov (United States)

    Greenberg, Erica; Tung, Esther S; Gauvin, Caitlin; Osiecki, Lisa; Yang, Kelly G; Curley, Erin; Essa, Angela; Illmann, Cornelia; Sandor, Paul; Dion, Yves; Lyon, Gholson J; King, Robert A; Darrow, Sabrina; Hirschtritt, Matthew E; Budman, Cathy L; Grados, Marco; Pauls, David L; Keuthen, Nancy J; Mathews, Carol A; Scharf, Jeremiah M

    2017-11-02

    Trichotillomania/hair pulling disorder (HPD) and excoriation/skin picking disorder (SPD) are childhood-onset, body-focused repetitive behaviors that are thought to share genetic susceptibility and underlying pathophysiology with obsessive-compulsive disorder (OCD) and Tourette syndrome (TS). We sought to determine the prevalence of DSM-5 HPD and SPD in TS patients, and to identify clinical factors most associated with their co-morbidity with TS. Participants included 811 TS patients recruited from TS specialty clinics for a multi-center genetic study. Patients were assessed using standardized, validated semi-structured interviews. HPD and SPD diagnoses were determined using a validated self-report questionnaire. HPD/SPD prevalence rates were calculated, and clinical predictors were evaluated using regression modeling. 3.8 and 13.0% of TS patients met DSM-5 criteria for HPD and SPD, respectively. In univariable analyses, female sex, OCD, and both tic and obsessive-compulsive symptom severity were among those associated with HPD and/or SPD. In multivariable analyses, only lifetime worst-ever motor tic severity remained significantly associated with HPD. Female sex, co-occurring OCD, ADHD, and motor tic severity remained independently associated with SPD. This is the first study to examine HPD and SPD prevalence in a TS sample using semi-structured diagnostic instruments. The prevalence of HPD and SPD in TS patients, and their association with increased tic severity and co-occurring OCD, suggests that clinicians should screen children with TS and related disorders for HPD/SPD, particularly in females and in those with co-occurring OCD. This study also helps set a foundation for subsequent research regarding HPD/SPD risk factors, pathophysiology, and treatment models.

  16. The effect of high protein diet and exercise on irisin, eNOS, and iNOS expressions in kidney.

    Science.gov (United States)

    Tastekin, Ebru; Palabiyik, Orkide; Ulucam, Enis; Uzgur, Selda; Karaca, Aziz; Vardar, Selma Arzu; Yilmaz, Ali; Aydogdu, Nurettin

    2016-08-01

    Long-term effects of high protein diets (HPDs) on kidneys are still not sufficiently studied. Irisin which increases oxygen consumption and thermogenesis in white fat cells was shown in skeletal muscles and many tissues. Nitric oxide synthases (NOS) are a family of enzymes catalyzing the production of nitric oxide (NO) from L-arginine. We aimed to investigate the effects of HPD, irisin and NO expression in kidney and relation of them with exercise and among themselves. Animals were grouped as control, exercise, HPD and exercise combined with HPD (exercise-HPD). Rats were kept on a HPD for 5 weeks and an exercise program was given them as 5 exercise and 2 rest days per week exercising on a treadmill with increasing speed and angle. In our study, while HPD group had similar total antioxidant capacity (TAC) levels with control group, exercise and exercise-HPD groups had lower levels (p highly selective and quite clear in this study. Effects of exercise and HPD on kidney should be evaluated with different exercise protocols and contents of the diet. İrisin, eNOS, and iNOS staining localizations should be supported with various research studies.

  17. Lowering the Barriers to Using Data: Enabling Desktop-based HPD Science through Virtual Environments and Web Data Services

    Science.gov (United States)

    Druken, K. A.; Trenham, C. E.; Steer, A.; Evans, B. J. K.; Richards, C. J.; Smillie, J.; Allen, C.; Pringle, S.; Wang, J.; Wyborn, L. A.

    2016-12-01

    The Australian National Computational Infrastructure (NCI) provides access to petascale data in climate, weather, Earth observations, and genomics, and terascale data in astronomy, geophysics, ecology and land use, as well as social sciences. The data is centralized in a closely integrated High Performance Computing (HPC), High Performance Data (HPD) and cloud facility. Despite this, there remain significant barriers for many users to find and access the data: simply hosting a large volume of data is not helpful if researchers are unable to find, access, and use the data for their particular need. Use cases demonstrate we need to support a diverse range of users who are increasingly crossing traditional research discipline boundaries. To support their varying experience, access needs and research workflows, NCI has implemented an integrated data platform providing a range of services that enable users to interact with our data holdings. These services include: - A GeoNetwork catalog built on standardized Data Management Plans to search collection metadata, and find relevant datasets; - Web data services to download or remotely access data via OPeNDAP, WMS, WCS and other protocols; - Virtual Desktop Infrastructure (VDI) built on a highly integrated on-site cloud with access to both the HPC peak machine and research data collections. The VDI is a fully featured environment allowing visualization, code development and analysis to take place in an interactive desktop environment; and - A Learning Management System (LMS) containing User Guides, Use Case examples and Jupyter Notebooks structured into courses, so that users can self-teach how to use these facilities with examples from our system across a range of disciplines. We will briefly present these components, and discuss how we engage with data custodians and consumers to develop standardized data structures and services that support the range of needs. We will also highlight some key developments that have

  18. Understanding speech when wearing communication headsets and hearing protectors with subband processing.

    Science.gov (United States)

    Brammer, Anthony J; Yu, Gongqiang; Bernstein, Eric R; Cherniack, Martin G; Peterson, Donald R; Tufts, Jennifer B

    2014-08-01

    An adaptive, delayless, subband feed-forward control structure is employed to improve the speech signal-to-noise ratio (SNR) in the communication channel of a circumaural headset/hearing protector (HPD) from 90 Hz to 11.3 kHz, and to provide active noise control (ANC) from 50 to 800 Hz to complement the passive attenuation of the HPD. The task involves optimizing the speech SNR for each communication channel subband, subject to limiting the maximum sound level at the ear, maintaining a speech SNR preferred by users, and reducing large inter-band gain differences to improve speech quality. The performance of a proof-of-concept device has been evaluated in a pseudo-diffuse sound field when worn by human subjects under conditions of environmental noise and speech that do not pose a risk to hearing, and by simulation for other conditions. For the environmental noises employed in this study, subband speech SNR control combined with subband ANC produced greater improvement in word scores than subband ANC alone, and improved the consistency of word scores across subjects. The simulation employed a subject-specific linear model, and predicted that word scores are maintained in excess of 90% for sound levels outside the HPD of up to ∼115 dBA.

  19. Eugenia uniflora fruit (red type) standardized extract: a potential pharmacological tool to diet-induced metabolic syndrome damage management.

    Science.gov (United States)

    Oliveira, Pathise Souto; Chaves, Vitor Clasen; Bona, Natália Pontes; Soares, Mayara Sandrielly Pereira; Cardoso, Juliane de Souza; Vasconcellos, Flávia Aleixo; Tavares, Rejane Giacomelli; Vizzotto, Marcia; Silva, Luísa Mariano Cerqueira da; Grecco, Fabiane Borelli; Gamaro, Giovana Duzzo; Spanevello, Roselia Maria; Lencina, Claiton Leoneti; Reginatto, Flávio Henrique; Stefanello, Francieli Moro

    2017-08-01

    The aim of this study was to investigate the effect of Eugenia uniflora fruit (red type) extract on metabolic status, as well as on neurochemical and behavioral parameters in an animal model of metabolic syndrome induced by a highly palatable diet (HPD). Rats were treated for 150days and divided into 4 experimental groups: standard chow (SC) and water orally, SC and E. uniflora extract (200mg/kg daily, p.o), HPD and water orally, HPD and extract. Our data showed that HPD caused glucose intolerance, increased visceral fat, weight gain, as well as serum glucose, triacylglycerol, total cholesterol and LDL cholesterol; however, E. uniflora prevented these alterations. The extract decreased lipid peroxidation and prevented the reduction of superoxide dismutase and catalase activities in the prefrontal cortex, hippocampus and striatum of animals submitted to HPD. We observed a HPD-induced reduction of thiol content in these cerebral structures. The extract prevented increased acetylcholinesterase activity in the prefrontal cortex caused by HPD and the increase in immobility time observed in the forced swim test. Regarding chemical composition, LC/MS analysis showed the presence of nine anthocyanins as the major compounds. In conclusion, E. uniflora extract showed benefits against metabolic alterations caused by HPD, as well as exhibited antioxidant and antidepressant-like effects. Copyright © 2017. Published by Elsevier Masson SAS.

  20. Effectiveness of deep cleaning followed by hydrogen peroxide decontamination during high Clostridium difficile infection incidence.

    Science.gov (United States)

    Best, E L; Parnell, P; Thirkell, G; Verity, P; Copland, M; Else, P; Denton, M; Hobson, R P; Wilcox, M H

    2014-05-01

    Clostridium difficile infection (CDI) remains an infection control challenge, especially when environmental spore contamination and suboptimal cleaning may increase transmission risk. To substantiate the long-term effectiveness throughout a stroke rehabilitation unit (SRU) of deep cleaning and hydrogen peroxide decontamination (HPD), following a high incidence of CDI. Extensive environmental sampling (342 sites on each occasion) for C. difficile using sponge wipes was performed: before and after deep cleaning with detergent/chlorine agent; immediately following HPD; and on two further occasions, 19 days and 20 weeks following HPD. C. difficile isolates underwent polymerase chain reaction ribotyping and multi-locus variable repeat analysis (MLVA). C. difficile was recovered from 10.8%, 6.1%, 0.9%, 0% and 3.5% of sites at baseline, following deep cleaning, immediately after HPD, and 19 days and 20 weeks after HPD, respectively. C. difficile ribotypes recovered after deep cleaning matched those from CDI cases in the SRU during the previous 10 months. Similarly, 10/12 of the positive sites identified at 20 weeks post-HPD harboured the same C. difficile ribotype (002) and MLVA pattern as the isolate from the first post-HPD CDI case. CDI incidence [number of cases on SRU per 10 months (January-October 2011)] declined from 20 before to seven after the intervention. HPD, after deep cleaning with a detergent/chlorine agent, was highly effective for removing environmental C. difficile contamination. Long-term follow-up demonstrated that a CDI symptomatic patient can rapidly recontaminate the immediate environment. Determining a role for HPD should include long-term cost-effectiveness evaluations. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. High-protein diet selectively reduces fat mass and improves glucose tolerance in Western-type diet-induced obese rats

    Science.gov (United States)

    Stengel, Andreas; Goebel-Stengel, Miriam; Wang, Lixin; Hu, Eugenia; Karasawa, Hiroshi; Pisegna, Joseph R.

    2013-01-01

    Obesity is an increasing health problem. Because drug treatments are limited, diets remain popular. High-protein diets (HPD) reduce body weight (BW), although the mechanisms are unclear. We investigated physiological mechanisms altered by switching diet induced obesity (DIO) rats from Western-type diet (WTD) to HPD. Male rats were fed standard (SD) or WTD (45% calories from fat). After developing DIO (50% of rats), they were switched to SD (15% calories from protein) or HPD (52% calories from protein) for up to 4 weeks. Food intake (FI), BW, body composition, glucose tolerance, insulin sensitivity, and intestinal hormone plasma levels were monitored. Rats fed WTD showed an increased FI and had a 25% greater BW gain after 9 wk compared with SD (P Diet-induced obese rats switched from WTD to HPD reduced daily FI by 30% on day 1, which lasted to day 9 (−9%) and decreased BW during the 2-wk period compared with SD/SD (P < 0.05). During these 2 wk, WTD/HPD rats lost 72% more fat mass than WTD/SD (P < 0.05), whereas lean mass was unaltered. WTD/HPD rats had lower blood glucose than WTD/SD at 30 min postglucose gavage (P < 0.05). The increase of pancreatic polypeptide and peptide YY during the 2-h dark-phase feeding was higher in WTD/HPD compared with WTD/SD (P < 0.05). These data indicate that HPD reduces BW in WTD rats, which may be related to decreased FI and the selective reduction of fat mass accompanied by improved glucose tolerance, suggesting relevant benefits of HPD in the treatment of obesity. PMID:23883680

  2. High-protein diet improves sensitivity to cholecystokinin and shifts the cecal microbiome without altering brain inflammation in diet-induced obesity in rats.

    Science.gov (United States)

    Wang, Lixin; Jacobs, Jonathan P; Lagishetty, Venu; Yuan, Pu-Qing; Wu, Shuping V; Million, Mulugeta; Reeve, Joseph R; Pisegna, Joseph R; Taché, Yvette

    2017-10-01

    High-protein diet (HPD) curtails obesity and/or fat mass, but it is unknown whether it reverses neuroinflammation or alters glucose levels, CCK sensitivity, and gut microbiome in rats fed a Western diet (WD)-induced obesity (DIO). Male rats fed a WD (high fat and sugar) for 12 wk were switched to a HPD for 6 wk. Body composition, food intake, meal pattern, sensitivity to intraperitoneal CCK-8S, blood glucose, brain signaling, and cecal microbiota were assessed. When compared with a normal diet, WD increased body weight (9.3%) and fat mass (73.4%). CCK-8S (1.8 or 5.2 nmol/kg) did not alter food intake and meal pattern in DIO rats. Switching to a HPD for 6 wk reduced fat mass (15.7%) with a nonsignificantly reduced body weight gain, normalized blood glucose, and decreased feeding after CCK-8S. DIO rats on the WD or switched to a HPD showed comparable microbial diversity. However, in HPD versus WD rats, there was enrichment of 114 operational taxonomic units (OTUs) and depletion of 188 OTUs. Of those, Akkermansia muciniphila (enriched on a HPD), an unclassified Clostridiales, a member of the RF39 order, and a Phascolarctobacterium were significantly associated with fat mass. The WD increased cytokine expression in the hypothalamus and dorsal medulla that was unchanged by switching to HPD. These data indicate that HPD reduces body fat and restores glucose homeostasis and CCK sensitivity, while not modifying brain inflammation. In addition, expansion of cecal Akkermansia muciniphila correlated to fat mass loss may represent a potential peripheral mechanism of HPD beneficial effects.

  3. The Effect of a High-Protein Diet and Exercise on Cardiac AQP7 and GLUT4 Gene Expression.

    Science.gov (United States)

    Palabiyik, Orkide; Karaca, Aziz; Taştekin, Ebru; Yamasan, Bilge Eren; Tokuç, Burcu; Sipahi, Tammam; Vardar, Selma Arzu

    2016-10-01

    High-protein (HP) diets are commonly consumed by athletes despite their potential health hazard, which is postulated to enforce a negative effect on bone and renal health. However, its effects on heart have not been known yet. Aquaporin-7 (AQP7) is an aquaglyceroporin that facilitates glycerol and water transport. Glycerol is an important cardiac energy production substrate, especially during exercise, in conjunction with fatty acids and glucose. Glucose transporter 4 (GLUT4) is an insulin-sensitive glucose transporter in heart. We aimed to investigate the effect of HPD on AQP7 and GLUT4 levels in the rat heart subjected to exercise. Male Sprague-Dawley rats were divided into control (n = 12), exercise (E) training (n = 10), HPD (n = 12), and HPD-E training (n = 9) groups. The HPD groups were fed a 45 % protein-containing diet 5 weeks. The HPD-E and E groups were performed the treadmill exercise during the 5-week study period. Real-time polymerase chain reaction and immunohistochemistry techniques were used to determine the gene expression and localization of AQP7 and GLUT4 in heart tissue. Results of relative gene expression were calculated by the 'Pfaffl' mathematical method using the REST program. Differences in AQP7 and GLUT4 gene expression were expressed as fold change compared to the control group. Heart weight/tibia ratio and ventricular wall thickness were evaluated as markers of cardiac hypertrophy. Further, serum glucose, glycerol, and insulin levels were also measured. AQP7 gene expression was found to be increased in the E (3.47-fold, p protein expression was also increased in the HPD and HPD-E groups (p protein expression was significantly increased in the E, HPD, and HPD-E groups compared to the control group (p = 0.024, p protein diet groups (C and E). Serum insulin levels were higher for HPD groups compared with the normal-protein diet groups (p < 0.001), whereas no differences were observed between the exercise and sedentary

  4. Sheep model for osteoporosis: The effects of peripheral hormone therapy on centrally induced systemic bone loss in an osteoporotic sheep model.

    Science.gov (United States)

    Oheim, Ralf; Simon, Maciej J K; Steiner, Malte; Vettorazzi, Eik; Barvencik, Florian; Ignatius, Anita; Amling, Michael; Clarke, Iain J; Pogoda, Pia; Beil, F Timo

    2017-04-01

    Hypothalamic-pituitary disconnection (HPD) leads to low bone turnover followed by bone loss and reduced biomechanical properties in sheep. To investigate the role of peripheral hormones in this centrally induced systemic bone loss model, we planned a hormone replacement experiment. Therefore, estrogen (OHE), thyroxin (OHT) or a combination of both (OHTE) was substituted in ovariectomized HPD sheep, as both hormones are decreased in HPD sheep and are known to have a significant but yet not fully understood impact on bone metabolism. Bone turnover and structural parameters were analyzed in comparison to different control groups - untreated sheep (C), ovariectomized (O) and ovariectomized+HPD sheep (OH). We performed histomorphometric and HR-pQCT analyses nine months after the HPD procedure, as well as biomechanical testing of all ewes studied. In HPD sheep (OH) the low bone turnover led to a significant bone loss. Treatment with thyroxin alone (OHT) mainly increased bone resorption, leading to a further reduction in bone volume. In contrast, the treatment with estrogen alone (OHE) and the combined treatment with estrogen and thyroxin (OHTE) prevented HPD-induced bone loss completely. In conclusion, peripheral hormone substitution was able to prevent HPD-induced low-turnover osteoporosis in sheep. But only the treatment with estrogen alone or in combination with thyroxin was able to completely preserve bone mass and structure. These findings demonstrate the importance of peripheral hormones for a balanced bone remodeling and a physiological bone turnover. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. MDEP Generic Common Position No DICWG-05. Common position on the treatment of hardware description language (HDL) programmed devices for use in nuclear safety systems

    International Nuclear Information System (INIS)

    2013-01-01

    Following other industries, the nuclear industry developed increasing interest in the use of programmable logic components that are implemented using hardware description language (HDL) such as such as FPGAs, CPLDs or ASICs. HDL programmed devices (HPD) has both characteristics of software and hardware. Therefore applications using HPDs has many similarities with the traditional software (in particular the design may be affected by errors) and characteristics of traditional electronic design (e.g. electronic-level timing and electrical issues). However, due to the unique nature of HPDs, there exist several differences between HPDs and traditional software. Some key differences include: - HPDs use parallel processing with dedicated hardware for each function instead of executing instructions sequentially as in the case of traditional software. - Safety critical software uses imperative languages which specify each instruction of the program whereas HPDs use declarative languages. - The target of software is a microprocessor, which guarantees properties such as memory consistency after each instruction. Such properties are not inherent in HPDs and thus the design process needs different steps to build and guarantee behavioural properties. - Translation of the HDL description to bit-streams in HPDs is much more involved than the translation of source code to binary in software compilation. In the HPD case, this process is not fully automatic, and therefore designer must guide the tools, which may result in undetectable errors. The Digital Instrumentation and Controls Working Group (DICWG) has agreed that a common position on this topic is warranted given the increase of use of Digital I and C in new reactor designs, its safety implications, and the need to develop a common understanding from the perspectives of regulatory authorities. This action follows the DICWG examination of the regulatory requirements of the participating members and of relevant industry

  6. The NCI High Performance Computing (HPC) and High Performance Data (HPD) Platform to Support the Analysis of Petascale Environmental Data Collections

    Science.gov (United States)

    Evans, B. J. K.; Pugh, T.; Wyborn, L. A.; Porter, D.; Allen, C.; Smillie, J.; Antony, J.; Trenham, C.; Evans, B. J.; Beckett, D.; Erwin, T.; King, E.; Hodge, J.; Woodcock, R.; Fraser, R.; Lescinsky, D. T.

    2014-12-01

    The National Computational Infrastructure (NCI) has co-located a priority set of national data assets within a HPC research platform. This powerful in-situ computational platform has been created to help serve and analyse the massive amounts of data across the spectrum of environmental collections - in particular the climate, observational data and geoscientific domains. This paper examines the infrastructure, innovation and opportunity for this significant research platform. NCI currently manages nationally significant data collections (10+ PB) categorised as 1) earth system sciences, climate and weather model data assets and products, 2) earth and marine observations and products, 3) geosciences, 4) terrestrial ecosystem, 5) water management and hydrology, and 6) astronomy, social science and biosciences. The data is largely sourced from the NCI partners (who include the custodians of many of the national scientific records), major research communities, and collaborating overseas organisations. By co-locating these large valuable data assets, new opportunities have arisen by harmonising the data collections, making a powerful transdisciplinary research platformThe data is accessible within an integrated HPC-HPD environment - a 1.2 PFlop supercomputer (Raijin), a HPC class 3000 core OpenStack cloud system and several highly connected large scale and high-bandwidth Lustre filesystems. New scientific software, cloud-scale techniques, server-side visualisation and data services have been harnessed and integrated into the platform, so that analysis is performed seamlessly across the traditional boundaries of the underlying data domains. Characterisation of the techniques along with performance profiling ensures scalability of each software component, all of which can either be enhanced or replaced through future improvements. A Development-to-Operations (DevOps) framework has also been implemented to manage the scale of the software complexity alone. This ensures that

  7. Epithelial response to a high-protein diet in rat colon.

    Science.gov (United States)

    Beaumont, Martin; Andriamihaja, Mireille; Armand, Lucie; Grauso, Marta; Jaffrézic, Florence; Laloë, Denis; Moroldo, Marco; Davila, Anne-Marie; Tomé, Daniel; Blachier, François; Lan, Annaïg

    2017-01-31

    High-protein diets (HPD) alter the large intestine microbiota composition in association with a metabolic shift towards protein degradation. Some amino acid-derived metabolites produced by the colon bacteria are beneficial for the mucosa while others are deleterious at high concentrations. The aim of the present work was to define the colonic epithelial response to an HPD. Transcriptome profiling was performed on colonocytes of rats fed an HPD or an isocaloric normal-protein diet (NPD) for 2 weeks. The HPD downregulated the expression of genes notably implicated in pathways related to cellular metabolism, NF-κB signaling, DNA repair, glutathione metabolism and cellular adhesion in colonocytes. In contrast, the HPD upregulated the expression of genes related to cell proliferation and chemical barrier function. These changes at the mRNA level in colonocytes were not associated with detrimental effects of the HPD on DNA integrity (comet assay), epithelium renewal (quantification of proliferation and apoptosis markers by immunohistochemistry and western blot) and colonic barrier integrity (Ussing chamber experiments). The modifications of the luminal environment after an HPD were associated with maintenance of the colonic homeostasis that might be the result of adaptive processes in the epithelium related to the observed transcriptional regulations.

  8. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Kamoya, Masatoshi

    2001-01-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  9. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kamoya, Masatoshi [Kanazawa Medical Univ., Ishikawa (Japan)

    2001-03-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  10. Histrionic personality disorder and antisocial personality disorder: sex-differentiated manifestations of psychopathy?

    Science.gov (United States)

    Cale, Ellison M; Lilienfeld, Scott O

    2002-02-01

    Little is known about the etiology of histrionic personality disorder (HPD) or its relation to other personality disorders. In this study, we examined whether HPD is etiologically related to psychopathy and more specifically whether HPD and antisocial personality disorder (ASPD) are sex-typed alternative manifestations of psychopathy. In addition, based on Newman's (1987) response modulation hypothesis of psychopathy, we examined the associations between psychopathic, HPD, and ASPD features and performance on laboratory measures of passive avoidance errors and interference effects. Seventy-five live theater actors completed self-report questionnaires and two laboratory measures of response modulation, and peers completed questionnaires concerning the participants' personality disorder features. The results provided weak and inconsistent support for the hypotheses that HPD is a female-typed variant of psychopathy and that ASPD is a male-typed variant of psychopathy. Contrary to previous findings, scores on response modulation tasks were not significantly related to psychopathy, or to either HPD or ASPD. The limitations of this study and possibilities for future research in this area are outlined.

  11. Is the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, histrionic personality disorder category a valid construct?

    Science.gov (United States)

    Bakkevig, Jonas F; Karterud, Sigmund

    2010-01-01

    The study investigated crucial aspects of the construct validity of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) histrionic personality disorder (HPD) category. The study included 2289 patients from the Norwegian Network of Psychotherapeutic Day Hospitals. Construct validity was assessed by means of prevalence, comorbidity with other personality disorders, internal consistency among HPD criteria, severity indices, as well as factor analyses. The prevalence of HPD was very low (0.4 %). The comorbidity was high, especially with borderline, narcissistic, and dependent personality disorders. The internal consistency was low. The criteria seemed to form 2 separate clusters: the first contained exhibitionistic and attention-seeking traits and the other contained impressionistic traits. The results indicated poor construct validity of the HPD category. Different options for the future of the category are discussed. The authors suggest the HPD category to be deleted from the DSM system. However, the clinical phenomena of exhibitionism and attention-seeking, which are the dominant personality features of HPD, should be preserved in an exhibitionistic subtype of narcissism. Copyright 2010 Elsevier Inc. All rights reserved.

  12. Noise-Induced Hearing Loss - A Preventable Disease? Results of a 10-Year Longitudinal Study of Workers Exposed to Occupational Noise.

    Science.gov (United States)

    Frederiksen, Thomas W; Ramlau-Hansen, Cecilia H; Stokholm, Zara A; Grynderup, Matias B; Hansen, Åse M; Kristiansen, Jesper; Vestergaard, Jesper M; Bonde, Jens P; Kolstad, Henrik A

    2017-01-01

    To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD) over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and the follow-up populations according to first year of occupational noise exposure is evaluated. In 2001-2003, we conducted a baseline survey of noise- and hearing-related disorders in 11 industries with suspected high noise levels. In 2009-2010, we were able to follow up on 271 out of the 554 baseline workers (49%). Mean noise levels per industry and self-reported HPD use are described at baseline and follow-up. The association between cumulative occupational noise exposure and hearing threshold shift over the 10-year period was assessed using linear regression, and the risk of hearing loss according to year of first occupational noise exposure was evaluated with logistic regression. Over the 10-year period, mean noise levels declined from 83.9 dB(A) to 82.8 dB(A), and for workers exposed >85 dB(A), the use of HPD increased from 70.1 to 76.1%. We found a weak, statistically insignificant, inverse association between higher ambient cumulative noise exposure and poorer hearing (-0.10 dB hearing threshold shift per dB-year (95% confidence interval (CI): -0.36; 0.16)). The risk of hearing loss seemed to increase with earlier first year of noise exposure, but odds ratios were only statistically significant among baseline participants with first exposure before the 1980s (odds ratio: 1.90, 95% CI: 1.11; 3.22). We observed declining industrial noise levels, increased use of HPD and no significant impact on hearing thresholds from current ambient industrial noise levels, which indicated a successful implementation of Danish hearing conservation programs.

  13. The Colonic Microbiome and Epithelial Transcriptome Are Altered in Rats Fed a High-Protein Diet Compared with a Normal-Protein Diet.

    Science.gov (United States)

    Mu, Chunlong; Yang, Yuxiang; Luo, Zhen; Guan, Leluo; Zhu, Weiyun

    2016-03-01

    A high-protein diet (HPD) can produce hazardous compounds and reduce butyrate-producing bacteria in feces, which may be detrimental to gut health. However, information on whether HPD affects intestinal function is limited. The aim of this study was to determine the impact of an HPD on the microbiota, microbial metabolites, and epithelial transcriptome in the colons of rats. Adult male Wistar rats were fed either a normal-protein diet (20% protein, 56% carbohydrate) or an HPD (45% protein, 30% carbohydrate) for 6 wk (n = 10 rats per group, individually fed). After 6 wk, the colonic microbiome, microbial metabolites, and epithelial transcriptome were determined. Compared with the normal-protein diet, the HPD adversely altered the colonic microbiota by increasing (P 0.7, P < 0.05) with genes and metabolites generally regarded as being involved in disease pathogenesis, suggesting these bacteria may mediate the detrimental effects of HPDs on colonic health. Our findings suggest that the HPD altered the colonic microbial community, shifted the metabolic profile, and affected the host response in the colons of rats toward an increased risk of colonic disease. © 2016 American Society for Nutrition.

  14. A New Murine Model of Chronic Kidney Disease-Mineral and Bone Disorder

    Directory of Open Access Journals (Sweden)

    Bianca Frauscher

    2017-01-01

    Full Text Available Chronic kidney disease (CKD is associated with mineral and bone disorder (MBD, which is the main cause of the extensively increased cardiovascular mortality in the CKD population. We now aimed to establish a new murine experimental CKD-MBD model. Dilute brown non-Agouti (DBA/2 mice were fed with high-phosphate diet for 4 (HPD4 or 7 (HPD7 days, then with standard chow diet (SCD and subsequently followed until day 84. They were compared to DBA/2 mice maintained on SCD during the whole study period. Both 4 and 7 days HPD-fed mice developed phosphate nephropathy with tubular atrophy, interstitial fibrosis, decreased glomerular filtration rate, and increased serum urea levels. The abdominal aorta of HPD-treated mice showed signs of media calcification. Histomorphometric analysis of HPD-treated mice showed decreased bone volume/tissue volume, low mineral apposition rate, and low bone formation rate as compared to SCD-fed mice, despite increased parathyroid hormone levels. Overall, the observed phenotype was more pronounced in the HPD7 group. In summary, we established a new, noninvasive, and therefore easy to perform reproducible CKD-MBD model, which showed media calcification, secondary hyperparathyroidism, and low-turnover bone disease.

  15. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Science.gov (United States)

    Binks, Michael J; Temple, Beth; Kirkham, Lea-Ann; Wiertsema, Selma P; Dunne, Eileen M; Richmond, Peter C; Marsh, Robyn L; Leach, Amanda J; Smith-Vaughan, Heidi C

    2012-01-01

    Unambiguous identification of nontypeable Haemophilus influenzae (NTHi) is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh); however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22), Hh (n = 27) or equivocal (n = 11), were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3) and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  16. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Directory of Open Access Journals (Sweden)

    Michael J Binks

    Full Text Available BACKGROUND: Unambiguous identification of nontypeable Haemophilus influenzae (NTHi is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh; however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. METHODOLOGY/PRINCIPAL FINDINGS: Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22, Hh (n = 27 or equivocal (n = 11, were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3 and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. CONCLUSIONS/SIGNIFICANCE: Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  17. Numerical simulation of current-free double layers created in a helicon plasma device

    Science.gov (United States)

    Rao, Sathyanarayan; Singh, Nagendra

    2012-09-01

    Two-dimensional simulations reveal that when radially confined source plasma with magnetized electrons and unmagnetized ions expands into diverging magnetic field B, a current-free double layer (CFDL) embedded in a conical density structure forms, as experimentally measured in the Australian helicon plasma device (HPD). The magnetized electrons follow the diverging B while the unmagnetized ions tend to flow directly downstream of the source, resulting in a radial electric field (E⊥) structure, which couples the ion and electron flows. Ions are transversely (radially) accelerated by E⊥ on the high potential side of the double layer in the CFDL. The accelerated ions are trapped near the conical surface, where E⊥ reverses direction. The potential structure of the CFDL is U-shaped and the plasma density is enhanced on the conical surface. The plasma density is severely depleted downstream of the parallel potential drop (φ||o) in the CFDL; the density depletion and the potential drop are related by quasi-neutrality condition, including the divergence in the magnetic field and in the plasma flow in the conical structure. The potential and density structures, the CFDL spatial size, its electric field strengths and the electron and ion velocities and energy distributions in the CFDL are found to be in good agreements with those measured in the Australian experiment. The applicability of our results to measured axial potential profiles in magnetic nozzle experiments in HPDs is discussed.

  18. Community-based blood pressure measurement by non-health workers using electronic devices: a validation study

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2012-06-01

    Full Text Available Introduction: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers. Method: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis. Results: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5–7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: −2.9 to −10.0 for diastolic blood pressure. Conclusion: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.

  19. Questioning the coherence of histrionic personality disorder: borderline and hysterical personality subtypes in adults and adolescents.

    Science.gov (United States)

    Blagov, Pavel S; Westen, Drew

    2008-11-01

    After the introduction of histrionic personality disorder (HPD), nosologists struggled to reduce its overlap with borderline personality disorder and other PDs. We studied the coherence of HPD in adults and adolescents as part of 2 larger studies. Clinicians described a random patient with personality pathology using rigorous psychometrics, including the SWAP-II (a Q-sort that captures personality and its pathology in adults) in study 1 and the SWAP-II-A (the adolescent version) in study 2. Using DSM-IV-based measures, we identified patients who met HPD criteria with varying degrees of diagnostic confidence. Central tendencies in the SWAP-II and SWAP-II-A profiles revealed that both the most descriptive and most distinctive features of the patients included some features of HPD but also many features of borderline personality disorder. Q-factor analyses of the SWAP data yielded 3 types of patients in each of the 2 samples. The HPD diagnosis may not be sufficiently coherent or valid.

  20. Serum levels of hematoporphyrin derivatives in the photodynamic therapy of malignant tumors

    Science.gov (United States)

    Chan, H. K.; Low, K. S.; Haji Baba, A. S.; Arimbalam, S.; Yip, C. H.; Chang, K. W.; Baskaran, G.; Lo, Y. L.; Jayalakshmi, P.; Looi, L. M.; Tan, N. H.

    1995-03-01

    In photodynamic therapy (PDT), red light is administered 24 - 72 hours post intravenous (i.v.) injection of hematoporphyrin derivatives (HpD). In an earlier animal model study, more effective therapeutic response was obtained when red light irradiation was carried out 15 mins after the injection of HpD. The effectiveness of this immediate PDT protocol has been correlated to the high serum level of HpD immediately after administration and the destruction of the microcirculation system as the dominant tumor destruction mechanism. This study examines the pharmacokinetics and the serum levels of HpD in rats and also in human patients. Such data can assist in defining the optimum time delay for light irradiation in the PDT of cancer.

  1. Feasibility analysis of heat pump dryer to dry hawthorn cake

    International Nuclear Information System (INIS)

    Wang, D.C.; Zhang, G.; Han, Y.P.; Zhang, J.P.; Tian, X.L.

    2011-01-01

    Highlights: → A heat pump dryer (HPD) is effectively proposed to dry hawthorn cake-likely materials. → Low drying temperature and high COP of heat pump are obtained in drying beginning. → HPD is more effective, economic than a traditional hot air dryer. → Feasibility of the HPD is also validated by the operation economy estimation. - Abstract: A heat pump dryer (HPD) would be an economic, environmentally friendly, hygienic drying machine used to dry some food, such as hawthorn cakes. Based on the production process of the hawthorn cake, a HPD is proposed and its basic principle is introduced. The experimental drying curves of the hawthorn cake using the heat pump drying method and the traditional hot air drying method are compared and analyzed. The drying process of hawthorn cakes is similar to that of the other drying materials. The higher drying temperature causes a faster drying process. But in the initial stage of the heat pump drying process, the water content of the hawthorn cake is not sensitive to the drying temperature, so a lower drying air temperature can be available in order to get a higher coefficient of performance (COP) of the heat pump (HP). The experimental results and the economic analysis indicate that the HPD is feasibly used to dry hawthorn cakes.

  2. Feasibility analysis of heat pump dryer to dry hawthorn cake

    Energy Technology Data Exchange (ETDEWEB)

    Wang, D.C., E-mail: wdechang@163.com [College of Electromechanical Engineering, Qingdao University, Qingdao 266071 (China); Zhang, G.; Han, Y.P.; Zhang, J.P.; Tian, X.L. [College of Electromechanical Engineering, Qingdao University, Qingdao 266071 (China)

    2011-08-15

    Highlights: {yields} A heat pump dryer (HPD) is effectively proposed to dry hawthorn cake-likely materials. {yields} Low drying temperature and high COP of heat pump are obtained in drying beginning. {yields} HPD is more effective, economic than a traditional hot air dryer. {yields} Feasibility of the HPD is also validated by the operation economy estimation. - Abstract: A heat pump dryer (HPD) would be an economic, environmentally friendly, hygienic drying machine used to dry some food, such as hawthorn cakes. Based on the production process of the hawthorn cake, a HPD is proposed and its basic principle is introduced. The experimental drying curves of the hawthorn cake using the heat pump drying method and the traditional hot air drying method are compared and analyzed. The drying process of hawthorn cakes is similar to that of the other drying materials. The higher drying temperature causes a faster drying process. But in the initial stage of the heat pump drying process, the water content of the hawthorn cake is not sensitive to the drying temperature, so a lower drying air temperature can be available in order to get a higher coefficient of performance (COP) of the heat pump (HP). The experimental results and the economic analysis indicate that the HPD is feasibly used to dry hawthorn cakes.

  3. Dentate gyrus and hilus transection blocks seizure propagation and granule cell dispersion in a mouse model for mesial temporal lobe epilepsy.

    Science.gov (United States)

    Pallud, Johan; Häussler, Ute; Langlois, Mélanie; Hamelin, Sophie; Devaux, Bertrand; Deransart, Colin; Depaulis, Antoine

    2011-03-01

    Epilepsy-associated changes of the anatomical organization of the dentate gyrus and hilus may play a critical role in the initiation and propagation of seizures in mesial temporal lobe epilepsy (MTLE). This study evaluated the role of longitudinal projections in the propagation of hippocampal paroxysmal discharges (HPD) in dorsal hippocampus by performing a selective transection in a mouse model for MTLE obtained by a single unilateral intrahippocampal injection of kainic acid (KA). Full transections of the dentate gyrus and hilus were performed in the transverse axis at 22 days after KA injection when spontaneous HPD were fully developed. They: (i) significantly reduced the occurrence of HPD; (ii) increased their duration at the KA injection site; (iii) abolished their spread along the longitudinal axis of the hippocampal formation and; (iv) limited granule cell dispersion (GCD) of the dentate gyrus posterior to the transection. These data suggest that: (i) longitudinal projections through the dentate gyrus and hilus are involved in HPD spread; (ii) distant hippocampal circuits participate in the generation and cessation of HPD and; (iii) GCD requires continuous HPD to develop, even when seizures are established. Our data reveal a critical role for longitudinal projections in the generation and spread of hippocampal seizures. Copyright © 2010 Wiley-Liss, Inc.

  4. NCI's High Performance Computing (HPC) and High Performance Data (HPD) Computing Platform for Environmental and Earth System Data Science

    Science.gov (United States)

    Evans, Ben; Allen, Chris; Antony, Joseph; Bastrakova, Irina; Gohar, Kashif; Porter, David; Pugh, Tim; Santana, Fabiana; Smillie, Jon; Trenham, Claire; Wang, Jingbo; Wyborn, Lesley

    2015-04-01

    The National Computational Infrastructure (NCI) has established a powerful and flexible in-situ petascale computational environment to enable both high performance computing and Data-intensive Science across a wide spectrum of national environmental and earth science data collections - in particular climate, observational data and geoscientific assets. This paper examines 1) the computational environments that supports the modelling and data processing pipelines, 2) the analysis environments and methods to support data analysis, and 3) the progress so far to harmonise the underlying data collections for future interdisciplinary research across these large volume data collections. NCI has established 10+ PBytes of major national and international data collections from both the government and research sectors based on six themes: 1) weather, climate, and earth system science model simulations, 2) marine and earth observations, 3) geosciences, 4) terrestrial ecosystems, 5) water and hydrology, and 6) astronomy, social and biosciences. Collectively they span the lithosphere, crust, biosphere, hydrosphere, troposphere, and stratosphere. The data is largely sourced from NCI's partners (which include the custodians of many of the major Australian national-scale scientific collections), leading research communities, and collaborating overseas organisations. New infrastructures created at NCI mean the data collections are now accessible within an integrated High Performance Computing and Data (HPC-HPD) environment - a 1.2 PFlop supercomputer (Raijin), a HPC class 3000 core OpenStack cloud system and several highly connected large-scale high-bandwidth Lustre filesystems. The hardware was designed at inception to ensure that it would allow the layered software environment to flexibly accommodate the advancement of future data science. New approaches to software technology and data models have also had to be developed to enable access to these large and exponentially

  5. In vivo assessment of 111In-labeled hematoporphyrin derivative in breast tumor-bearing animals

    International Nuclear Information System (INIS)

    Wong, D.W.; Mandal, Ashis; Brown, Jerry; Reese, I.C.; Siegler, Richard; Hyman, Shigeyo

    1989-01-01

    The biological behavior of 111 In-labeled HPD has been investigated in tumor-bearing animals. Mice mammary adenocarcinomas and 7,12-dimethylbenz(a)anthracine induced breast tumors in Sprague-Dawley female rats were clearly visualized by 111 In-HPD nuclear scintigraphy. Optimal scans were obtained after a 48 h delay. In normal and tumor-bearing animals, the highest uptake of 111 In-HPD 72 h post-injection was found in the liver, the spleen and the kidneys. Depending on the size and the extent of necrosis, the uptake of 111 In-HPD by malignant breast tumors varied from 2.5% injected dose (ID) in mice to 1% ID in rats. Benign breast tumor uptake of 111 In-HPD was less than 1% ID. No significant amount of the radiopharmaceutical was found in pulmonary abscesses and abdominal cysts. Scintigrams of these infectious or inflammatory lesions were normal. Malignant tumor to blood, heart and lung ratios averaged 50:1, 10:1 and 3:1 respectively. Tumor to brain ratio ranged from 72 to 444:1. (author)

  6. Noise-Induced Hearing Loss – A Preventable Disease? Results of a 10-Year Longitudinal Study of Workers Exposed to Occupational Noise

    Science.gov (United States)

    Frederiksen, Thomas W.; Ramlau-Hansen, Cecilia H.; Stokholm, Zara A.; Grynderup, Matias B.; Hansen, Åse M.; Kristiansen, Jesper; Vestergaard, Jesper M.; Bonde, Jens P.; Kolstad, Henrik A.

    2017-01-01

    Aims: To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD) over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and the follow-up populations according to first year of occupational noise exposure is evaluated. Materials and Methods: In 2001–2003, we conducted a baseline survey of noise- and hearing-related disorders in 11 industries with suspected high noise levels. In 2009–2010, we were able to follow up on 271 out of the 554 baseline workers (49%). Mean noise levels per industry and self-reported HPD use are described at baseline and follow-up. The association between cumulative occupational noise exposure and hearing threshold shift over the 10-year period was assessed using linear regression, and the risk of hearing loss according to year of first occupational noise exposure was evaluated with logistic regression. Results: Over the 10-year period, mean noise levels declined from 83.9 dB(A) to 82.8 dB(A), and for workers exposed >85 dB(A), the use of HPD increased from 70.1 to 76.1%. We found a weak, statistically insignificant, inverse association between higher ambient cumulative noise exposure and poorer hearing (−0.10 dB hearing threshold shift per dB-year (95% confidence interval (CI): −0.36; 0.16)). The risk of hearing loss seemed to increase with earlier first year of noise exposure, but odds ratios were only statistically significant among baseline participants with first exposure before the 1980s (odds ratio: 1.90, 95% CI: 1.11; 3.22). Conclusions: We observed declining industrial noise levels, increased use of HPD and no significant impact on hearing thresholds from current ambient industrial noise levels, which indicated a successful implementation of Danish hearing conservation programs. PMID:29192620

  7. Noise-Induced Hearing Loss – A Preventable Disease? Results of a 10-Year Longitudinal Study of Workers Exposed to Occupational Noise

    Directory of Open Access Journals (Sweden)

    Thomas W Frederiksen

    2017-01-01

    Full Text Available Aims: To survey current, Danish industrial noise levels and the use of hearing protection devices (HPD over a 10-year period and to characterise the association between occupational noise and hearing threshold shift in the same period. Furthermore, the risk of hearing loss among the baseline and the follow-up populations according to first year of occupational noise exposure is evaluated. Materials and Methods: In 2001–2003, we conducted a baseline survey of noise- and hearing-related disorders in 11 industries with suspected high noise levels. In 2009–2010, we were able to follow up on 271 out of the 554 baseline workers (49%. Mean noise levels per industry and self-reported HPD use are described at baseline and follow-up. The association between cumulative occupational noise exposure and hearing threshold shift over the 10-year period was assessed using linear regression, and the risk of hearing loss according to year of first occupational noise exposure was evaluated with logistic regression. Results: Over the 10-year period, mean noise levels declined from 83.9 dB(A to 82.8 dB(A, and for workers exposed >85 dB(A, the use of HPD increased from 70.1 to 76.1%. We found a weak, statistically insignificant, inverse association between higher ambient cumulative noise exposure and poorer hearing (−0.10 dB hearing threshold shift per dB-year (95% confidence interval (CI: −0.36; 0.16. The risk of hearing loss seemed to increase with earlier first year of noise exposure, but odds ratios were only statistically significant among baseline participants with first exposure before the 1980s (odds ratio: 1.90, 95% CI: 1.11; 3.22. Conclusions: We observed declining industrial noise levels, increased use of HPD and no significant impact on hearing thresholds from current ambient industrial noise levels, which indicated a successful implementation of Danish hearing conservation programs.

  8. Molecular dynamics simulations of Hsp40 J-domain mutants identifies disruption of the critical HPD-motif as the key factor for impaired curing in vivo of the yeast prion [URE3].

    Science.gov (United States)

    Xue, You-Lin; Wang, Hao; Riedy, Michael; Roberts, Brittany-Lee; Sun, Yuna; Song, Yong-Bo; Jones, Gary W; Masison, Daniel C; Song, Youtao

    2018-05-01

    Genetic screens using Saccharomyces cerevisiae have identified an array of Hsp40 (Ydj1p) J-domain mutants that are impaired in the ability to cure the yeast [URE3] prion through disrupting functional interactions with Hsp70. However, biochemical analysis of some of these Hsp40 J-domain mutants has so far failed to provide major insight into the specific functional changes in Hsp40-Hsp70 interactions. To explore the detailed structural and dynamic properties of the Hsp40 J-domain, 20 ns molecular dynamic simulations of 4 mutants (D9A, D36A, A30T, and F45S) and wild-type J-domain were performed, followed by Hsp70 docking simulations. Results demonstrated that although the Hsp70 interaction mechanism of the mutants may vary, the major structural change was targeted to the critical HPD motif of the J-domain. Our computational analysis fits well with previous yeast genetics studies regarding highlighting the importance of J-domain function in prion propagation. During the molecular dynamics simulations several important residues were identified and predicted to play an essential role in J-domain structure. Among these residues, Y26 and F45 were confirmed, using both in silico and in vivo methods, as being critical for Ydj1p function.

  9. The effects of diet-induced obesity on hepatocyte insulin signaling pathways and induction of non-alcoholic liver damage

    Directory of Open Access Journals (Sweden)

    Sameer Fatani

    2011-03-01

    Full Text Available Sameer Fatani1, Imose Itua2, Paul Clark3, Christopher Wong3, Ebrahim K Naderali21Obesity Biology Unit, School of Clinical Sciences, University of Liverpool, Liverpool, UK; 2Department of Health and Applied Social Sciences, Liverpool Hope University, Hope Park, Liverpool UK; 3Aintree University Hospital NHS Foundation Trust, Longmoor Lane, Liverpool, UKAbstract: The prevalence of diet-induced obesity is increasing amongst adults and children worldwide, predisposing millions of people to an array of health problems that include metabolic syndrome, non-alcoholic fatty liver disease and non-alcoholic steatohepatitis. In this study we used experimental animals to investigate the effects of dietary obesity on markers of hepatic insulin signaling as well as structural changes in hepatocytes. Adult male Wistar rats were randomized and assigned to either a control group or a test group. Controls were fed standard laboratory pelleted diet (chow-fed, while the test group had free access to a highly-palatable diet (HPD. After eight weeks, the HPD-fed animals were subdivided into three subgroups and their diets altered as follows: HPD-to-chow, HPD with the addition of fenofibrate given by oral gavage for a further seven weeks, or HPD with vehicle (1% carboxymethylcellulose at 1 mL/kg body weight given by oral gavage for a further seven weeks, respectively. Untreated diet-fed animals had significantly higher body weight, liver weight, and all measured metabolic profiles compared with chow-fed and treated diet-fed groups. Expression of kinases IRβ, IRS-1, AKt, eNOS, Shc and ERK1/2 were unaffected by obesity, while IRS-2 and P I3 kinase levels were significantly reduced in untreated HPD animals. Compared with chow-fed animals, steatosis and steatohepatitis were almost doubled in animals from untreated HPD, while removal of HPD and fenofibrate-treatment reduced steatosis by 40% and 80% respectively. These data suggest that diet-induced obesity affects

  10. Vaccinium virgatum fruit extract as an important adjuvant in biochemical and behavioral alterations observed in animal model of metabolic syndrome.

    Science.gov (United States)

    Oliveira, Pathise Souto; Gazal, Marta; Flores, Natália Porto; Zimmer, Aline Rigon; Chaves, Vitor Clasen; Reginatto, Flávio Henrique; Kaster, Manuella Pinto; Tavares, Rejane Giacomelli; Spanevello, Roselia Maria; Lencina, Claiton Leoneti; Stefanello, Francieli Moro

    2017-04-01

    The aim of this study was to investigate the effect of blueberry (Vaccinium virgatum) fruit extract on metabolic, behavioral and oxidative stress parameters in the hippocampus and cerebral cortex of mice submitted to an experimental model of metabolic syndrome induced by a highly palatable diet (HPD). Mice C57BL/6 were divided into 4 experimental groups: (1) received standard chow and saline orally, (2) received standard chow and blueberry hydroalcoholic extract, (3) received HPD and saline orally, (4) received HPD and blueberry hydroalcoholic extract. The animals were treated for 150days. Our results showed that the animals fed with HPD presented insulin resistance, increased body weight, visceral fat, glucose, triglycerides, and total cholesterol when compared to the control group. The blueberry extract prevented the increase of these metabolic parameters. Also, the extract was able to reduce the levels of thiobarbituric acid reactive substances in the cerebral cortex and hippocampus of animals submitted to HPD. In contrast, no differences were observed in the total thiol content, activity of the antioxidant enzymes catalase and superoxide dismutase. In addition, the HPD fed animals showed a significant increase in immobility time in the forced swimming test and blueberry prevented this alteration, although no changes were observed in the ambulatory behavior, as well as in the anxiolytic profile of these animals. Overall, our findings suggest that chronic consumption of blueberry extract exhibits hypoglycemic, hypolipidemic, antidepressant-like and antiperoxidative effects in an animal model of metabolic syndrome. Copyright © 2017. Published by Elsevier Masson SAS.

  11. PubMed search strategies for the identification of etiologic associations between hypothalamic-pituitary disorders and other medical conditions.

    Science.gov (United States)

    Guaraldi, Federica; Grottoli, Silvia; Arvat, Emanuela; Mattioli, Stefano; Ghigo, Ezio; Gori, Davide

    2013-12-01

    Biomedical literature has enormously grown in the last decades and become broadly available through online databases. Ad-hoc search methods, created on the basis of research field and goals, are required to enhance the quality of searching. Aim of this study was to formulate efficient, evidence-based PubMed search strategies to retrieve articles assessing etiologic associations between a condition of interest and hypothalamic-pituitary disorders (HPD). Based on expert knowledge, 17 MeSH (Medical Subjects Headings) and 79 free terms related to HPD were identified to search PubMed. Using random samples of abstracts retrieved by each term, we estimated the proportion of articles containing pertinent information and formulated two strings (one more specific, one more sensitive) for the detection of articles focusing on the etiology of HPD, that were then applied to retrieve articles identifying possible etiologic associations between HPD and three diseases (malaria, LHON and celiac disease) considered not associated to HPD, and define the number of abstracts needed to read (NNR) to find one potentially pertinent article. We propose two strings: one sensitive string derived from the combination of articles providing the largest literature coverage in the field and one specific including combined terms retrieving ≥40% of potentially pertinent articles. NNR were 2.1 and 1.6 for malaria, 3.36 and 2.29 for celiac disease, 2.8 and 2.2 for LHON, respectively. For the first time, two reliable, readily applicable strings are proposed for the retrieval of medical literature assessing putative etiologic associations between HPD and other medical conditions of interest.

  12. Blood flow in transplantable bladder tumors treated with hematoporphyrin derivative and light

    International Nuclear Information System (INIS)

    Selman, S.H.; Kreimer-Birnbaum, M.; Klaunig, J.E.; Goldblatt, P.J.; Keck, R.W.; Britton, S.L.

    1984-01-01

    Following hematoporphyrin derivative (HPD) photochemotherapy, blood flow to transplantable N-[4-(5-nitro-2-furyl)-2-thia-zolyl] formamide-induced urothelial tumors was determined by a radioactive microsphere technique using either 103 Ru or 141 Ce. Two tumors were implanted s.c. on the abdominal wall of Fischer 344 weanling rats. HPD (10 mg/kg body weight) was administered 24 hr prior to phototherapy (red light, greater than 590 nm; 360 J/sq cm). One of the two tumors was shielded from light exposure and served as an internal control. Blood flows were determined in control animals that received no treatment (Group 1), HPD only (Group 2), or light only (Group 3). In Groups 4 and 5, animals received the combination of HPD and light but differed in the time interval between treatment and blood flow determinations (10 min and 24 hr, respectively). Only blood flow to tumors treated with HPD and light showed a significant decrease (p less than 0.05) when compared with their internal controls both at 10 min (Group 4) and 24 hr (Group 5) after completion of phototherapy. These studies suggest that disruption of tumor blood flow may be an important mechanism of action of this method of cancer therapy

  13. Level-Dependent Nonlinear Hearing Protector Model in the Auditory Hazard Assessment Algorithm for Humans

    Science.gov (United States)

    2015-04-01

    HPD model. In an article on measuring HPD attenuation, Berger (1986) points out that Real Ear Attenuation at Threshold (REAT) tests are...men. Audiology . 1991;30:345–356. Fedele P, Binseel M, Kalb J, Price GR. Using the auditory hazard assessment algorithm for humans (AHAAH) with

  14. A bright side, facet analysis of histrionic personality disorder: the relationship between the HDS Colourful factor and the NEO-PI-R facets in a large adult sample.

    Science.gov (United States)

    Furnham, Adrian

    2014-01-01

    This study looks at "bright-side," Big Five Personality trait correlates of a "dark-side" Personality Disorder, namely Histrionic Personality Disorder (HPD). More than 5000 British adults completed the Neuroticism Extraversion Openness Personality Inventory-Revised (Costa & McCrae, 1985), which measures the Big Five Personality factors at the Domain (Super Factor) and the Facet (Factor) level, as well as the Hogan Development Survey (HDS; Hogan & Hogan, 2009), which has a measure of HPD, exclusively called "Colourful" in the HDS terminology. Correlation and regression results confirmed many of the associations between these "bright" and "dark" side individual difference variables. The Colourful (HPD) score from the HDS was the criterion variable in all analyses. Colourful individuals are high on Extraversion and Openness, but also Stable and disagreeable. The Facet analysis identified Assertiveness and Immodesty as particularly characteristic of that type. The study confirmed work on HPD using different population groups and different measures, showing that personality traits are predictable and correlated with various personality disorders.

  15. In vitro human periodontal ligament-like tissue formation with porous poly-L-lactide matrix

    International Nuclear Information System (INIS)

    Liao, Wen; Okada, Masahiro; Sakamoto, Fumito; Okita, Naoya; Inami, Kaoru; Nishiura, Aki; Hashimoto, Yoshiya; Matsumoto, Naoyuki

    2013-01-01

    This study aimed to establish an in vitro human periodontal ligament-like tissue (HPdLLT) by three-dimensional culturing of human periodontal ligament fibroblasts (HPdLFs) in a porous poly-L-lactide (PLLA) matrix modified hydrophilically with ammonia solution. After ammonia modification, the surface roughness and culture-medium-soaking-up ability of the PLLA matrix increased, whereas the contact angle of water drops decreased. The thickness, porosity, and pore size of the PLLA matrix were 400 ± 50 μm, 83.3%, and 75–150 μm, respectively. HPdLFs (1 × 10 5 cells) were seeded on the modified PLLA matrix and centrifuged to facilitate seeding into its interior and cultured for 14 days. Scanning electron microscope (SEM) observation, proliferation assay, picrosirius-red staining, and real-time polymerase chain reaction (RT-PCR) for type-1 collagen (COL1), periodontal ligament associated protein-1 (PLAP-1), fibroblast growth factor-2 (FGF-2), and alkaline phosphatase (ALP) mRNA were conducted on days 1, 3, 7, and 14. HPdLFs were observed entirely from the surface to the rear side of the matrix. Cell proliferation analysis, SEM observation, and picrosirius-red staining showed both progressive growth of 3D-cultured HPdLFs and extracellular matrix maturation by the secretion of COL1 and type 3 collagen (COL3) from days 1 to 14. Expressions of COL1, PLAP-1, and FGF-2 mRNA suggested the formation of cellular components and supplementation of extracellular components. Expressions of ALP, COL1, and PLAP-1 mRNA suggested the osteogenic potential of the HPdLLT. The results indicated in vitro HPdLLT formation, and it could be used in future periodontal ligament tissue engineering to achieve optimal periodontal regeneration. - Highlights: • First report on ammonia treated PLLA matrix for in vitro human periodontal ligament-like tissue generation. • Good combination of matrix thickness, pore size, and porosity. • Biodegradable PLLA is also possible to be used in vivo

  16. In vitro human periodontal ligament-like tissue formation with porous poly-L-lactide matrix

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Wen [Graduate School of Dentistry, Department of Orthodontics, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata-shi, Osaka-fu 573-1121 (Japan); Okada, Masahiro [Department of Biomaterials, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata-shi, Osaka-fu 573-1121 (Japan); Sakamoto, Fumito; Okita, Naoya [Graduate School of Dentistry, Department of Orthodontics, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata-shi, Osaka-fu 573-1121 (Japan); Inami, Kaoru; Nishiura, Aki [Department of Orthodontics, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata-shi, Osaka-fu 573-1121 (Japan); Hashimoto, Yoshiya, E-mail: yoshiya@cc.osaka-dent.ac.jp [Department of Biomaterials, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata-shi, Osaka-fu 573-1121 (Japan); Matsumoto, Naoyuki [Department of Orthodontics, Osaka Dental University, 8-1 Kuzuha-hanazono-cho, Hirakata-shi, Osaka-fu 573-1121 (Japan)

    2013-08-01

    This study aimed to establish an in vitro human periodontal ligament-like tissue (HPdLLT) by three-dimensional culturing of human periodontal ligament fibroblasts (HPdLFs) in a porous poly-L-lactide (PLLA) matrix modified hydrophilically with ammonia solution. After ammonia modification, the surface roughness and culture-medium-soaking-up ability of the PLLA matrix increased, whereas the contact angle of water drops decreased. The thickness, porosity, and pore size of the PLLA matrix were 400 ± 50 μm, 83.3%, and 75–150 μm, respectively. HPdLFs (1 × 10{sup 5} cells) were seeded on the modified PLLA matrix and centrifuged to facilitate seeding into its interior and cultured for 14 days. Scanning electron microscope (SEM) observation, proliferation assay, picrosirius-red staining, and real-time polymerase chain reaction (RT-PCR) for type-1 collagen (COL1), periodontal ligament associated protein-1 (PLAP-1), fibroblast growth factor-2 (FGF-2), and alkaline phosphatase (ALP) mRNA were conducted on days 1, 3, 7, and 14. HPdLFs were observed entirely from the surface to the rear side of the matrix. Cell proliferation analysis, SEM observation, and picrosirius-red staining showed both progressive growth of 3D-cultured HPdLFs and extracellular matrix maturation by the secretion of COL1 and type 3 collagen (COL3) from days 1 to 14. Expressions of COL1, PLAP-1, and FGF-2 mRNA suggested the formation of cellular components and supplementation of extracellular components. Expressions of ALP, COL1, and PLAP-1 mRNA suggested the osteogenic potential of the HPdLLT. The results indicated in vitro HPdLLT formation, and it could be used in future periodontal ligament tissue engineering to achieve optimal periodontal regeneration. - Highlights: • First report on ammonia treated PLLA matrix for in vitro human periodontal ligament-like tissue generation. • Good combination of matrix thickness, pore size, and porosity. • Biodegradable PLLA is also possible to be used in vivo.

  17. Study of the occlusion effect induced by an earplug: Numerical modelling and experimental validation

    Science.gov (United States)

    Brummund, Martin

    Despite existing limits for occupational noise exposure, professional hearing loss remains a high priority problem both in Quebec and worldwide. Several approaches exist to protect workers from harmful noise levels. The most frequently employed short term solution includes the distribution of hearing protection devices (HPD) such as earplugs and ear muffs. While HPDs offer an inexpensive (e.g. direct cost) and efficient means of protection workers often only tend to wear HPDs for limited amounts of time and, thus, remain at risk of developing professional hearing loss. Discomfort while using HPDs contributes to HPD underutilization and non-use. Two more general categories of discomfort can be distinguished. The category physical discomfort includes, for instance, problems such as heating of the ear and irritation of the ear canal that that occur upon earplug insertion. The category auditory discomfort refers to alterations in the auditory perception of sounds and one's own voice as well as hindered workplace communications. One important auditory discomfort that promotes HPD non-use is the occlusion effect. The occlusion effect occurs upon earplug insertion and describes sound amplification phenomena in the occluded ear canal at the low frequencies. The sound amplification is both perceivable and measurable (e.g., open and occluded sound pressure levels, hearing threshold shift). Additionally, the occlusion effect causes the HPD wearer to perceive his/her own voice as being distorted (e.g. hollow sounding) and physiological noises (e.g. respiration, blood circulation) are amplified also subsequent to earplug insertion. Reducing the occlusion effect has the potential to increase the auditory comfort of HPDs and could help preventing occupational hearing loss in the future. In order to improve this and other shortcomings observed with currently existing HPDs a large research collaboration between the Robert-Sauve research institute in occupational health and safety

  18. A 'LEGO' Hybrid Photon Detector - assembled from standard mass-produced vacuum components

    International Nuclear Information System (INIS)

    Ferenc, Daniel; Lorenz, Eckart; Mirzoyan, Razmik

    2000-01-01

    Motivated primarily by the MAGIC atmospheric Cherenkov telescope project, we have developed a 'LEGO' Hybrid Photon Detector (HPD) comprising excellent focusing properties and protection against positive ion feedback. LEGO-HPD is supposed to be assembled from standard high vacuum components, which insures simplicity in the assembly procedure and reliability of operation

  19. A time series evaluation of the treatment of histrionic personality disorder with cognitive analytic therapy.

    Science.gov (United States)

    Kellett, Stephen

    2007-09-01

    The central aim of this study was to assess the effectiveness of cognitive analytic therapy (CAT) with a patient presenting with Histrionic Personality Disorder (HPD). The methodology employed an A/B single case time-series experimental design, with additionally 6 months of continuous follow-up in the experimental measures. Five HPD experimental variables were collected on a daily basis, creating 357 days of continual data for analysis, across various phases of assessment baseline (A), treatment (B) and follow-up. The therapy contract was 24 sessions of CAT, with 4 additional follow-up sessions, spread over the 6-month's post-therapy period. Three out of the five HPD experimental variables (focus on physical appearance, emptiness and child inside) displayed statistically significant phase of treatment effects. Graphing of such data indicated that a 'sudden deterioration' occurred at the point of termination, with eventual recovery and maintenance of the progress made during the intervention. A battery of validated clinical measures were also completed at assessment, termination and final follow-up sessions; analysis of the general measures illustrated clinically significant change, indexing personality integration and reductions to depression. The study is discussed in terms of methodological and clinical limitations, the central importance of process issues and effective termination in HPD, plus the potential utility of CAT in the treatment of HPD presentations.

  20. X-ray study of a SODART flight telescope using the expanded beam x-ray optics beamline at the Daresbury synchrotron

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Hornstrup, Allan; Frederiksen, P. K.

    1995-01-01

    to contribute to the HPD by approximately 10%. If 33% of the geometric telescope area near the edges of the quadrants are covered a reduction of 10% of the HPD can be obtained. On- and off-axis images generated from the one dimensional intensity distribution are presented. Finally the data have been used...

  1. High-Resolution and Lightweight X-ray Optics for the X-Ray Surveyor

    Science.gov (United States)

    Zhang, William

    Envisioned in "Enduring Quest, Daring Visions" and under study by NASA as a potential major mission for the 2020s, the X-ray Surveyor mission will likely impose three requirements on its optics: (1) high angular resolution: 0.5 PSF, (2) large effective area: e10,000 cm2 or more, and (3) affordable production cost: $500M. We propose a technology that can meet these requirements by 2020. It will help the X-ray Surveyor secure the endorsement of the coming decadal survey and enable its implementation following WFIRST. The technology comprises four elements: (1) fabrication of lightweight single crystal silicon mirrors, (2) coating these mirrors with iridium to maximize effective area without figure degradation, (3) alignment and bonding of these mirrors to form meta-shells that will be integrated to make a mirror assembly, and (4) systems engineering to ensure that the mirror assembly meet all science performance and spaceflight environmental requirements. This approach grows out of our existing approach based on glass slumping. Using glass slumping technology, we have been able to routinely build and test mirror modules of 10half-power diameter (HPD). While comparable in HPD to XMM-Newtons electroformed nickel mirrors, these mirror modules are 10 times lighter. Likewise, while comparable in weight to Suzakus epoxy-replicated aluminum foil mirrors, these modules have 10 times better HPD. These modules represent the current state of the art of lightweight X-ray optics. Although both successful and mature, the glass slumping technology has reached its limit and cannot achieve sub-arc second HPD. Therefore, we are pursuing the new approach based on polishing single crystal silicon. The new approach will enable the building and testing of mirror modules, called meta-shells, capable of 3HPD by 2018 and 1HPD by 2020, and has the potential to reach diffraction limits ( 0.1) in the 2020s.

  2. Large-aperture hybrid photo-detector

    International Nuclear Information System (INIS)

    Kawai, Y.; Nakayama, H.; Kusaka, A.; Kakuno, H.; Abe, T.; Iwasaki, M.; Aihara, H.; Tanaka, M.; Shiozawa, M.; Kyushima, H.; Suyama, M.

    2007-01-01

    We have developed the first complete large-aperture (13-inch diameter) hybrid photo-detector (HPD). The withstanding voltage problem has been overcome and we were able to attain an HPD operating voltage of +20 kV. Adoption of our newly developed backside illumination avalanche diode (AD) was also critical in successfully countering the additional problem of an increase in AD leakage after the activation process. We observed single photon signal timing jitter of under 450 ps in FWHM, electron transit time of ∼12 ns, and clear pulse height separation up to several photoelectron peaks, all greatly superior to the performance of any conventional large-aperture photomultiplier tubes (PMTs). In addition, our HPD has a much simpler structure than conventional large-aperture PMTs, which simplifies mass production and lowers manufacturing cost. We believe that these attributes position our HPD as the most suitable photo-detector for the next generation mega-ton class water-Cherenkov detector, which is expected to be more than 20x larger than the Super-Kamiokande (SK) detector

  3. Photodynamic effect of hematoporphyrin derivative as a function of optical spectrum and incident energy density

    International Nuclear Information System (INIS)

    Kinsey, J.H.; Cortese, D.A.; Moses, H.L.; Ryan, R.J.; Branum, E.L.

    1981-01-01

    Tumor cell killing effect of hematoporphyrin derivative (HPD) and light was studied in culture to determine the dependence of this effect on treatment variables. Particular attention has been given to the spectral characteristics of the light and the absorption properties of hematoporphyrin. A human tumor cell line was treated using HPD and three broad bands of light ranging from the short- to the long-wavelength end of the visible spectrum. Cell killing was assessed by trypan blue exclusion. A transformed mouse embryo cell line was treated in a similar manner, and its reproductive efficiency was determined following treatment. Results of both studies are consistent with the hypothesis that the photocytotoxic action of HPD plus light is directly proportional to the number of light quanta absorbed by the HPD in each cell. For thin layers of cells, such as in situ carcinoma, it appears that short-wavelength radiation falling in the porphyrin Soret band around 400 nm may have from 12 to 30 times the killing power as does red light

  4. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  5. Fundamental study of photoradiation therapy for cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kashimura, Hiromasa; Kawakita, Isao; Nakahara, Akira; Sai, Shoki; Mitamura, Keiji; Fukutomi, Hisayuki; Sakita, Takao

    1984-12-01

    In an attempt to obtain basic data for endoscopical photoactivation therapy for cancer, photoactivation effect of various porphyrins have been studied using a human hepatoceller carcinoma cell line (PLC/PRF/5) and its transplanted tumors. Porphyrins tested were hematoporphyrin derivative (HpD), protoporphyrin disodium (PPNa), hematoporphyrin (Hp), coproporphyrin, and cobalt-protoporphyrin (COPP). To investigate cytocidal effects by laser irradiation with these drugs, the /sup 51/Cr release assay was used. The results indicate that laser irradiation only has no cytocidal effect, while PPNa has more intense cytocidal effect than that of HpD. To investigate anti-tumor effect by PRT further, 2mg of HpD, 2mg of PPNa or 0.9% NaCl were injected into human hepatocellar cartinomas transplanted to the flanks of BALB/c nu nu mice 48 hours before laser irradiation (514.5nm, 0.1 W, 30 min). The results were analized with respect to effects on tumor regression curve and their histology. The results suggest that laser irradiation alone has no antitumor effect, while PRT with PPNa has stronger anti-tumor effect than PRT with HpD. Therefore, PPNa may be used as a new photosensitizer for photoradiation therapy for cancer. (author).

  6. Anti-tumor immunotherapy by blockade of the PD-1/PD-L1 pathway with recombinant human PD-1-IgV.

    Science.gov (United States)

    Zhang, C; Wu, S; Xue, X; Li, M; Qin, X; Li, W; Han, W; Zhang, Y

    2008-01-01

    Blockade of the programmed death-1 (PD-1)/PD-ligand 1 (PD-L1) pathway can delay tumor growth and prolong the survival of tumor-bearing mice. The extracellular immunoglobulin (Ig) V domain of PD-1 is important for the interaction between PD-1 and PD-L1, suggesting that PD-1-IgV may be a potential target for anti-tumor immunotherapy. The extracellular sequence of human PD-1-IgV (hPD-1-IgV) was expressed in Escherichia coli and purified. The anti-tumor effect of hPD-1-IgV on tumor-bearing mice was tested. hPD-1-IgV recombinant protein could bind PD-L1 at molecular and cellular levels and enhance Cytotoxic T Lymphocyte (CTL) activity and anti-tumor effect on tumor-bearing mice in vivo. The percentage of CD4(+)CD25(+) T cells in tumor-bearing mice was decreased compared with control mice after administration of the recombinant protein. Our results suggest that inhibition of the interaction between PD-1 and PD-L1 by hPD-1-IgV may be a promising strategy for specific tumor immunotherapy.

  7. Computation of posterior distribution in Bayesian analysis – application in an intermittently used reliability system

    Directory of Open Access Journals (Sweden)

    V. S.S. Yadavalli

    2002-09-01

    Full Text Available Bayesian estimation is presented for the stationary rate of disappointments, D∞, for two models (with different specifications of intermittently used systems. The random variables in the system are considered to be independently exponentially distributed. Jeffreys’ prior is assumed for the unknown parameters in the system. Inference about D∞ is being restrained in both models by the complex and non-linear definition of D∞. Monte Carlo simulation is used to derive the posterior distribution of D∞ and subsequently the highest posterior density (HPD intervals. A numerical example where Bayes estimates and the HPD intervals are determined illustrates these results. This illustration is extended to determine the frequentistical properties of this Bayes procedure, by calculating covering proportions for each of these HPD intervals, assuming fixed values for the parameters.

  8. Application of symplectic integrator to numerical fluid analysis

    International Nuclear Information System (INIS)

    Tanaka, Nobuatsu

    2000-01-01

    This paper focuses on application of the symplectic integrator to numerical fluid analysis. For the purpose, we introduce Hamiltonian particle dynamics to simulate fluid behavior. The method is based on both the Hamiltonian formulation of a system and the particle methods, and is therefore called Hamiltonian Particle Dynamics (HPD). In this paper, an example of HPD applications, namely the behavior of incompressible inviscid fluid, is solved. In order to improve accuracy of HPD with respect to space, CIVA, which is a highly accurate interpolation method, is combined, but the combined method is subject to problems in that the invariants of the system are not conserved in a long-time computation. For solving the problems, symplectic time integrators are introduced and the effectiveness is confirmed by numerical analyses. (author)

  9. Device-Centric Monitoring for Mobile Device Management

    Directory of Open Access Journals (Sweden)

    Luke Chircop

    2016-03-01

    Full Text Available The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centric properties (e.g. the user may not send more than 100 messages per day across all applications being difficult or impossible to verify. In this paper we present a device-centric approach to runtime verify the device behaviour against a device policy with the different applications acting as independent components contributing to the overall behaviour of the device. We also present an implementation for Android devices, and evaluate it on a number of device-centric policies, reporting the empirical results obtained.

  10. Power source device for thermonuclear device

    International Nuclear Information System (INIS)

    Ozaki, Akira.

    1992-01-01

    The present invention provides a small sized and economical power source device for a thermonuclear device. That is, the device comprises a conversion device having a rated power determined by a power required during a plasma current excitation period and a conversion device having a rated power determined by a power required during a plasma current maintaining period, connected in series to each other. Then, for the former conversion device, power is supplied from an electric power generator and, for the latter, power is supplied from a power system. With such a constitution, during the plasma electric current maintaining period for substantially continuous operation, it is possible to conduct bypassing paired operation for the former conversion device while the electric power generator is put under no load. Further, since a short period rated power may be suffice for the former conversion device and the electric power generator having the great rated power required for the plasma electric current excitation period, they can be reduced in the size and made economical. On the other hand, since the power required for the plasma current maintaining period is relatively small, the capacity of the continuous rated conversion device may be small, and the power can be received from the power system. (I.S.)

  11. A compact readout system for multi-pixel hybrid photodiodes

    International Nuclear Information System (INIS)

    Datema, C.P.; Meng, L.J.; Ramsden, D.

    1999-01-01

    Although the first Multi-pixel Hybrid Photodiode (M-HPD) was developed in the early 1990s by Delft Electronic Products, the main obstacle to its application has been the lack of availability of a compact read-out system. A fast, parallel readout system has been constructed for use with the earlier 25-pixel tube with High-energy Physics applications in mind. The excellent properties of the recently developed multi-pixel hybrid photodiodes (M-HPD) will be easier to exploit following the development of the new hybrid read-out circuits described in this paper. This system will enable all of the required read-out functions to be accommodate on a single board into which the M-HPD is plugged. The design and performance of a versatile system is described in which a trigger-signal, derived from the common-side of the silicon anode in the M-HPD, is used to trigger the readout of the 60-anode pixels in the M-HPD. The multi-channel amplifier section is based on the use of a new, commercial VLSI chip, whilst the read-out sequencer uses a chip of its own design. The common anode signal is processed by a fast amplifier and discriminator to provide a trigger signal when a single event is detected. In the prototype version, the serial analogue output data-stream is processed using a PC-mounted, high speed ADC. Results obtained using the new read-out system in a compact gamma-camera and with a small muon tracking-chamber demonstrate the low-noise performance of the system. The application of this read-out system in other position-sensitive or multi-anode photomultiplier tube applications are also described

  12. Device-Centric Monitoring for Mobile Device Management

    OpenAIRE

    Chircop, Luke; Colombo, Christian; Pace, Gordon J.

    2016-01-01

    The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centri...

  13. Long-Term Intake of a High-Protein Diet Affects Body Phenotype, Metabolism, and Plasma Hormones in Mice.

    Science.gov (United States)

    Vu, John P; Luong, Leon; Parsons, William F; Oh, Suwan; Sanford, Daniel; Gabalski, Arielle; Lighton, John Rb; Pisegna, Joseph R; Germano, Patrizia M

    2017-12-01

    Background: High-protein diets (HPDs) recently have been used to obtain body weight and fat mass loss and expand muscle mass. Several studies have documented that HPDs reduce appetite and food intake. Objective: Our goal was to determine the long-term effects of an HPD on body weight, energy intake and expenditure, and metabolic hormones. Methods: Male C57BL/6 mice (8 wk old) were fed either an HPD (60% of energy as protein) or a control diet (CD; 20% of energy as protein) for 12 wk. Body composition and food intakes were determined, and plasma hormone concentrations were measured in mice after being fed and after overnight feed deprivation at several time points. Results: HPD mice had significantly lower body weight (in means ± SEMs; 25.73 ± 1.49 compared with 32.5 ± 1.31 g; P = 0.003) and fat mass (9.55% ± 1.24% compared with 15.78% ± 2.07%; P = 0.05) during the first 6 wk compared with CD mice, and higher lean mass throughout the study starting at week 2 (85.45% ± 2.25% compared with 75.29% ± 1.90%; P = 0.0001). Energy intake, total energy expenditure, and respiratory quotient were significantly lower in HPD compared with CD mice as shown by cumulative energy intake and eating rate. Water vapor was significantly higher in HPD mice during both dark and light phases. In HPD mice, concentrations of leptin [feed-deprived: 41.31 ± 11.60 compared with 3041 ± 683 pg/mL ( P = 0.0004); postprandial: 112.5 ± 102.0 compared with 8273 ± 1415 pg/mL ( P < 0.0001)] and glucagon-like peptide 1 (GLP-1) [feed-deprived: 5.664 ± 1.44 compared with 21.31 ± 1.26 pg/mL ( P = <0.0001); postprandial: 6.54 ± 2.13 compared with 50.62 ± 11.93 pg/mL ( P = 0.0037)] were significantly lower, whereas postprandial glucagon concentrations were higher than in CD-fed mice. Conclusions: In male mice, the 12-wk HPD resulted in short-term body weight and fat mass loss, but throughout the study preserved body lean mass and significantly reduced energy intake and expenditure as well as

  14. DSM-5 field survey

    DEFF Research Database (Denmark)

    Lochner, Christine; Grant, Jon E; Odlaug, Brian Lawrence

    2012-01-01

    The aim of this multisite field survey was to examine the DSM-IV-TR criteria, proposed DSM-5 diagnostic criteria, as well as a number of possible additional diagnostic criteria, in patients with hair-pulling disorder (HPD, or trichotillomania).......The aim of this multisite field survey was to examine the DSM-IV-TR criteria, proposed DSM-5 diagnostic criteria, as well as a number of possible additional diagnostic criteria, in patients with hair-pulling disorder (HPD, or trichotillomania)....

  15. Molecular diversity in irregular or refugee immigrant patients with HBV-genotype-E infection living in the metropolitan area of Naples.

    Science.gov (United States)

    Sagnelli, Caterina; Ciccozzi, Massimo; Coppola, Nicola; Minichini, Carmine; Lo Presti, Alessandra; Starace, Mario; Alessio, Loredana; Macera, Margherita; Cella, Eleonora; Gualdieri, Luciano; Caprio, Nunzio; Pasquale, Giuseppe; Sagnelli, Evangelista

    2017-06-01

    In a recent testing in the metropolitan area of Naples, Italy, on 945 irregular immigrants or refugees, 87 HBsAg chronic carriers were identified, 53 of whom were infected by HBV-genotype E. The aim of the present study was to identify the genetic diversity of HBV-genotype E in these 53 immigrants. The 53 immigrant patients with HBV-genotype-E infection were born in Africa, central or eastern Asia, eastern Europe or Latin America. These patients had been seen for a clinical consultation at one of the four first-level units from January 2012 to 2013. The first dataset contained 53 HBV-S gene isolates plus 128 genotype/subgenotype specific reference sequences downloaded from the National Center for Biotechnology Information. The second dataset, comprising the 53 HBV-S gene isolates, previously classified as HBV-genotype E, was used to perform the time-scaled phylogeny reconstruction using a Bayesian approach. Phylogenetic analysis showed that all 53 HBV-S isolates belonged to HBV-genotype E. Bayes factor analysis showed that the relaxed clock exponential growth model fitted the data significantly better than the other models. The time-scaled Bayesian phylogenetic tree of the second dataset showed that the root of the tree dated back to the year 1990 (95% HPD:1984-2000). Four statistically supported clusters were identified. Cluster A dated back to 2012 (95% HPD:1997-2012); cluster B dated back to 2008 (95% HPD:2001-2015); cluster C to 2006 (95% HPD:1999-2013); cluster D to 2004 (95% HPD:1998-2011). This study disclosed the genetic evolution and phylogenesis in a group of HBV-genotype-E-infected immigrants. J. Med. Virol. 89:1015-1024, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Use of FPGA and CPLD in nuclear reactor safety systems and its regulatory review requirements for reactor safety

    International Nuclear Information System (INIS)

    Roy, Suvadip; Biswas, Animesh; Pradhan, S.K.

    2015-01-01

    Field Programmable Gate Arrays (FPGA) and Complex Programmable Logic Devices (CPLD) is being used widely in safety critical and safety related systems in nuclear power plans like in trip logic units, Engineered Safety Feature (ESF) actuation decision logic and neutronic signal processing for their reprogrammability feature and compact design. These HDL Programmable devices (HPD) are complex devices consisting of both hardware and software which is used to implement the logic on the FPGA. It is observed that these Programmable devices suffer from various modes of failure and the major failures in these devices are due to Single Event Upset (SEU), where a highly energetic ionizing radiation may lead to device failure which can even occur in radiologically benign environment. Other failures can occur during steps of developing the hardware using software tools like during Synthesis and placement and routing of the desired hardware. Here a study on use of such devices in Nuclear Reactors, study on mode of failures of these devices, way to tackle such failure and development of review guidelines for review of such devices used in safety critical and safety related systems with special emphasis on choice of software tools, way to mitigate effects of SEU and simulation and hardware testing results to be reviewed by regulatory body during design safety review is done. (author)

  17. Ontology-Based Device Descriptions and Device Repository for Building Automation Devices

    Directory of Open Access Journals (Sweden)

    Dibowski Henrik

    2011-01-01

    Full Text Available Device descriptions play an important role in the design and commissioning of modern building automation systems and help reducing the design time and costs. However, all established device descriptions are specialized for certain purposes and suffer from several weaknesses. This hinders a further design automation, which is strongly needed for the more and more complex building automation systems. To overcome these problems, this paper presents novel Ontology-based Device Descriptions (ODDs along with a layered ontology architecture, a specific ontology view approach with virtual properties, a generic access interface, a triple store-based database backend, and a generic search mask GUI with underlying query generation algorithm. It enables a formal, unified, and extensible specification of building automation devices, ensures their comparability, and facilitates a computer-enabled retrieval, selection, and interoperability evaluation, which is essential for an automated design. The scalability of the approach to several ten thousand devices is demonstrated.

  18. Multi-Device to Multi-Device (MD2MD Content-Centric Networking Based on Multi-RAT Device

    Directory of Open Access Journals (Sweden)

    Cheolhoon Kim

    2017-11-01

    Full Text Available This paper proposes a method whereby a device can transmit and receive information using a beacon, and also describes application scenarios for the proposed method. In a multi-device to multi-device (MD2MD content-centric networking (CCN environment, the main issue involves searching for and connecting to nearby devices. However, if a device can’t find another device that satisfies its requirements, the connection is delayed due to the repetition of processes. It is possible to rapidly connect to a device without repetition through the selection of the optimal device using the proposed method. Consequently, the proposed method and scenarios are advantageous in that they enable efficient content identification and delivery in a content-centric Internet of Things (IoT environment, in which multiple mobile devices coexist.

  19. Scanning table BIP 101 for bubble chamber pictures

    International Nuclear Information System (INIS)

    Calmels, C.

    1966-09-01

    BIP 101 is a new scanning table for bubble chamber pictures, especially aimed at the full scale projection of the CERN 2 m hydrogen chamber. The table itself is divided in two half tables, each of them receiving, successively or simultaneously, the projections of 2 of the 4 films. Projectors with film transport are located in the central space between both half tables. Their light is reflected on 2 mirrors fixed at the ceiling. Thus the 4 sides of the table are freely accessible to the scanners. It will be possible to equip later the table with digitizers, allowing pre-measurements of the events for HPD device, or even measurements. (author) [fr

  20. Characterisation of the NA62 GigaTracker End of Column Demonstrator Hybrid Pixel Detector

    Science.gov (United States)

    Noy, M.; Aglieri Rinella, G.; Cotta Ramusino, A.; Fiorini, M.; Jarron, P.; Kaplon, J.; Kluge, A.; Martin, E.; Morel, M.; Perktold, L.; Poltorak, K.; Riedler, P.

    2011-11-01

    The architecture and characterisation of the NA62 GigaTracker End of Column Demonstrator Hybrid Pixel Detector (HPD) are presented. This detector must perform time stamping to 200 ps (RMS) or better, provide 300 μm pitch position information and operate with a dead time of 1% or less for 800 MHz-1 GHz beam rate. The demonstrator HPD Assembly comprises a readout chip with a test column of 45 pixels, alongside other test structures, bump bonded to a p-in-n detector 200 μm in thickness. Validation of the performance of the HPD and the time-over-threshold timewalk compensation mechanism with both beam particles and a high precision laser system was performed and is presented. Confirmation of better than the required time stamping precision has been demonstrated and subsequent work on the design of the full-scale ASIC, dubbed TDCPix, is underway. An overview of the TDCPix architecure is given.

  1. Separation of scutellarin from crude extracts of Erigeron breviscapus (vant.) Hand. Mazz. by macroporous resins.

    Science.gov (United States)

    Gao, Min; Huang, Wei; Liu, Chun-Zhao

    2007-10-15

    Scutellarin, a flavone glycoside, popularly used in the treatment of heart disease, has been efficiently separated using macroporous resins from crude extracts of Chinese medicinal plant Erigeron breviscapus (vant.) Hand. Mazz. HPD-800 resin offered the best adsorption and desorption capacity for scutellarin among the eight macroporous resins tested, and its adsorption data at 25 degrees C fit best to the Langmuir isotherm. The dynamic adsorption and desorption experiments have been carried out on a HPD-800 resin packed column to optimize the separation process of scutellarin from the crude extracts of E. breviscapus. After one run treatment with HPD-800 resin, the scutellarin content in the product was increased 15.69-fold from 2.61% to 40.96% with a recovery yield of 95.01%. The preparative separation process via adsorption-desorption method developed in this study provides a new approach for scale-up separation and purification of scutellarin for its wide pharmaceutical use.

  2. Effect of different drying techniques on bioactive components, fatty acid composition, and volatile profile of robusta coffee beans.

    Science.gov (United States)

    Dong, Wenjiang; Hu, Rongsuo; Chu, Zhong; Zhao, Jianping; Tan, Lehe

    2017-11-01

    This study investigated the effect of different drying techniques, namely, room-temperature drying (RTD), solar drying (SD), heat-pump drying (HPD), hot-air drying (HAD), and freeze drying (FD), on bioactive components, fatty acid composition, and the volatile compound profile of robusta coffee beans. The data showed that FD was an effective method to preserve fat, organic acids, and monounsaturated fatty acids. In contrast, HAD was ideal for retaining polyunsaturated fatty acids and amino acids. Sixty-two volatile compounds were identified in the differently dried coffee beans, representing 90% of the volatile compounds. HPD of the coffee beans produced the largest number of volatiles, whereas FD resulted in the highest volatile content. A principal component analysis demonstrated a close relationship between the HPD, SD, and RTD methods whereas the FD and HAD methods were significantly different. Overall, the results provide a basis for potential application to other similar thermal sensitive materials. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Mechanical cell disruption of Parachlorella kessleri microalgae: Impact on lipid fraction composition.

    Science.gov (United States)

    Clavijo Rivera, E; Montalescot, V; Viau, M; Drouin, D; Bourseau, P; Frappart, M; Monteux, C; Couallier, E

    2018-05-01

    Samples of nitrogen-starved Parachlorella kessleri containing intact cells (IC), cells ground by bead milling (BM), and cells subjected to high-pressure cell disruption (HPD), together with their supernatants after centrifugation, were compared for granulometry and lipid profiles. The effects of disruption on the lipid profile and organisation were evaluated. The quantity of lipids available for extraction increased with disruption, and up to 81% could be recovered in supernatants after centrifugation, but a marked reorganization occurred. The proportion of amphiphilic free fatty acids and lysophosphatidylcholine increased during disruption due to their release or owing to lipid degradation by enzymes or physical conditions. This effect was more marked in HPD than in BM. Lipids contained in the aqueous phase, after disruption and centrifugation, were enriched in unsaturated fatty acids, BM leading to larger droplets than HPD. The larger liquid lipid droplet would be easier to recover in the following downstream processing. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Graphene device and method of using graphene device

    Science.gov (United States)

    Bouchiat, Vincent; Girit, Caglar; Kessler, Brian; Zettl, Alexander K.

    2015-08-11

    An embodiment of a graphene device includes a layered structure, first and second electrodes, and a dopant island. The layered structure includes a conductive layer, an insulating layer, and a graphene layer. The electrodes are coupled to the graphene layer. The dopant island is coupled to an exposed surface of the graphene layer between the electrodes. An embodiment of a method of using a graphene device includes providing the graphene device. A voltage is applied to the conductive layer of the graphene device. Another embodiment of a method of using a graphene device includes providing the graphene device without the dopant island. A dopant island is placed on an exposed surface of the graphene layer between the electrodes. A voltage is applied to the conductive layer of the graphene device. A response of the dopant island to the voltage is observed.

  5. Humanitarian Use Devices/Humanitarian Device Exemptions in cardiovascular medicine.

    Science.gov (United States)

    Kaplan, Aaron V; Harvey, Elisa D; Kuntz, Richard E; Shiran, Hadas; Robb, John F; Fitzgerald, Peter

    2005-11-01

    The Second Dartmouth Device Development Symposium held in October 2004 brought together leaders from the medical device community, including clinical investigators, senior representatives from the US Food and Drug Administration, large and small device manufacturers, and representatives from the financial community to examine difficult issues confronting device development. The role of the Humanitarian Use Device/Humanitarian Device Exemption (HUD/HDE) pathway in the development of new cardiovascular devices was discussed in this forum. The HUD/HDE pathway was created by Congress to facilitate the availability of medical devices for "orphan" indications, ie, those affecting HDEs have been granted (23 devices, 6 diagnostic tests). As the costs to gain regulatory approval for commonly used devices increase, companies often seek alternative ways to gain market access, including the HUD/HDE pathway. For a given device, there may be multiple legitimate and distinct indications, including indications that meet the HUD criteria. Companies must choose how and when to pursue each of these indications. The consensus of symposium participants was for the HUD/HDE pathway to be reserved for true orphan indications and not be viewed strategically as part of the clinical development plan to access a large market.

  6. A review of heat pump drying: Part 1 - systems, models and studies

    Energy Technology Data Exchange (ETDEWEB)

    Colak, Neslihan [Dept. of Food Engineering, Faculty of Engineering, Pamukkale Univ., 20070 Denizli (Turkey); Hepbasli, Arif [Dept. of Mechanical Engineering, Faculty of Engineering, Ege Univ., 35100 Bornova, Izmir (Turkey)

    2009-09-15

    The first heat pump dryer (HPD) patent applications were started in 1973, while recently, there has been a great interest in utilizing HPDs for drying fruits, vegetables and biological materials. This study deals with reviewing heat pump drying studies and consists of two parts. In the first part of this study, historical development of HPDs was briefly given first. Description of these systems was then presented. Finally, studies conducted on HPD were reviewed in terms of process efficiency modeling and progress of quality. (author)

  7. Effect of a High-Protein Diet versus Standard-Protein Diet on Weight Loss and Biomarkers of Metabolic Syndrome: A Randomized Clinical Trial.

    Science.gov (United States)

    Campos-Nonato, Ismael; Hernandez, Lucia; Barquera, Simon

    2017-01-01

    Some studies have shown that protein-enriched diets can lead to greater weight loss and improvements in biomarkers of metabolic syndrome (MeS) than standard protein diets. Therefore, the aim of this study was to determine the effect of increased protein intake on weight loss in Mexican adults with MeS. Randomized controlled trial in 118 adults aged 47.4 ± 11.5 years and meeting the established criteria for MeS were randomized to prescribed hypocaloric diets (500 kcal less than resting metabolic rate) providing either 0.8 g/kg body weight (standard protein diet (SPD)) or 1.34 g/kg body weight (higher protein diet (HPD)) for 6 months. Body weight, waist circumference, percent body fat by bioimpedance analysis, fasting blood glucose, fasting insulin, hemoglobin A1c, total cholesterol, high-density lipoprotein (HDL) cholesterol, very-low-density lipoprotein (VLDL) cholesterol, triglycerides, C-reactive protein, creatinine, blood urea nitrogen, alanine aminotransferase, aspartate aminotransferase, and gamma-glutamyl transferase were measured at baseline, 3 months and at 6 months. There were 105 subjects (51 for SPD and 54 for HPD) who completed the trial. Overall weight loss was 5.1 ± 3.6 kg in the SPD group compared to 7.0 ± 3.7 kg in the in HPD group. Both groups lost a significant percent of centimeters of waist circumference (SPD -6.5 ± 2.6 cm and HPD -8.8 ± 2.6 cm). There was no statistical difference Except for the varying weight losses the two groups did not show any further differences overall. However in the subgroup judged to be adherent more than 75% of the time with the prescribed diets, there was a significant difference in mean weight loss (SPD -5.8% vs. HPD -9.5%) after adjusting for baseline BMI. Both groups demonstrated significant decreases in waist circumference, glucose, insulin, triglycerides, and VLDL cholesterol, but there were no differences between the groups. There were no changes in blood tests for liver or renal function. There were no

  8. Effect of a High-Protein Diet versus Standard-Protein Diet on Weight Loss and Biomarkers of Metabolic Syndrome: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Ismael Campos-Nonato

    2017-06-01

    Full Text Available Background: Some studies have shown that protein-enriched diets can lead to greater weight loss and improvements in biomarkers of metabolic syndrome (MeS than standard protein diets. Therefore, the aim of this study was to determine the effect of increased protein intake on weight loss in Mexican adults with MeS. Methods: Randomized controlled trial in 118 adults aged 47.4 ± 11.5 years and meeting the established criteria for MeS were randomized to prescribed hypocaloric diets (500 kcal less than resting metabolic rate providing either 0.8 g/kg body weight (standard protein diet (SPD or 1.34 g/kg body weight (higher protein diet (HPD for 6 months. Body weight, waist circumference, percent body fat by bioimpedance analysis, fasting blood glucose, fasting insulin, hemoglobin A1c, total cholesterol, high-density lipoprotein (HDL cholesterol, very-low-density lipoprotein (VLDL cholesterol, triglycerides, C-reactive protein, creatinine, blood urea nitrogen, alanine aminotransferase, aspartate aminotransferase, and gamma-glutamyl transferase were measured at baseline, 3 months and at 6 months. Results: There were 105 subjects (51 for SPD and 54 for HPD who completed the trial. Overall weight loss was 5.1 ± 3.6 kg in the SPD group compared to 7.0 ± 3.7 kg in the in HPD group. Both groups lost a significant percent of centimeters of waist circumference (SPD -6.5 ± 2.6 cm and HPD -8.8 ± 2.6 cm. There was no statistical difference Except for the varying weight losses the two groups did not show any further differences overall. However in the subgroup judged to be adherent more than 75% of the time with the prescribed diets, there was a significant difference in mean weight loss (SPD -5.8% vs. HPD -9.5% after adjusting for baseline BMI. Both groups demonstrated significant decreases in waist circumference, glucose, insulin, triglycerides, and VLDL cholesterol, but there were no differences between the groups. There were no changes in blood tests for

  9. DeviceNet-based device-level control in SSRF

    CERN Document Server

    Leng Yong Bin; Lu Cheng Meng; Miao Hai Feng; Liu Song Qiang; Shen Guo Bao

    2002-01-01

    The control system of Shanghai Synchrotron Radiation Facility is an EPICS-based distributed system. One of the key techniques to construct the system is the device-level control. The author describes the design and implementation of the DeviceNet-based device controller. A prototype of the device controller was tested in the experiments of magnet power supply and the result showed a precision of 3 x 10 sup - sup 5

  10. Hypocaloric high-protein diet improves fatty liver and hypertriglyceridemia in sucrose-fed obese rats via two pathways.

    Science.gov (United States)

    Uebanso, Takashi; Taketani, Yutaka; Fukaya, Makiko; Sato, Kazusa; Takei, Yuichiro; Sato, Tadatoshi; Sawada, Naoki; Amo, Kikuko; Harada, Nagakatsu; Arai, Hidekazu; Yamamoto, Hironori; Takeda, Eiji

    2009-07-01

    The mechanism by which replacement of some dietary carbohydrates with protein during weight loss favors lipid metabolism remains obscure. In this study, we investigated the effect of an energy-restricted, high-protein/low-carbohydrate diet on lipid metabolism in obese rats. High-sucrose-induced obese rats were assigned randomly to one of two energy-restricted dietary interventions: a carbohydrate-based control diet (CD) or a high-protein diet (HPD). Lean rats of the same age were assigned as normal control. There was significantly greater improvement in fatty liver and hypertriglyceridemia with the HPD diet relative to the CD diet. Expression of genes regulated by fibroblast growth factor-21 (FGF21) and involved in liver lipolysis and lipid utilitization, such as lipase and acyl-CoA oxidase, increased in obese rats fed the HPD. Furthermore, there was an inverse correlation between levels of FGF21 gene expression (regulated by glucagon/insulin balance) and increased triglyceride concentrations in liver from obese rats. Expression of hepatic stearoyl-CoA desaturase-1 (SCD1), regulated primarily by the dietary carbohydrate, was also markedly reduced in the HPD group (similar to plasma triglyceride levels in fasting animals) relative to the CD group. In conclusion, a hypocaloric high-protein diet improves fatty liver and hypertriglyceridemia effectively relative to a carbohydrate diet. The two cellular pathways at work behind these benefits include stimulation of hepatic lipolysis and lipid utilization mediated by FGF21 and reduction of hepatic VLDL-TG production by SCD1 regulation.

  11. Hearing protection use in manufacturing workers: A qualitative study

    Directory of Open Access Journals (Sweden)

    Ravi K Reddy

    2012-01-01

    Full Text Available Occupational noise is a significant contributor to disabling hearing loss worldwide. Noise-induced hearing loss (NIHL has resulted in huge human and economic consequences costing New Zealand approximately $53M annually and rising. A high proportion of hearing loss claims are made by workers in the manufacturing sector. Hearing protection devices (HPDs are used together with engineering and administrative controls to minimize noise exposure and to prevent hearing loss. Unfortunately, inconsistent and improper use of HPDs has hindered efforts to prevent NIHL. The purpose of this study was to understand the factors that influence the use of HPDs amongst a group of manufacturing workers in New Zealand. A purposive sample of twenty-five workers was recruited to take part in semi-structured interviews. The open-ended questions were aimed at exploring the participants′ knowledge, attitude, beliefs, and behavior towards noise and HPDs. The data were analyzed using conventional content analysis and key themes emerged in relation to HPD use. Themes that emerged from the interviews either supported good hearing protection behavior or acted as barriers against it. Five major themes, (perception of noise, hearing preservation, reluctance to use HPDs, workplace interaction, and value of hearing and sub-themes described various factors that influence hearing protection use. Both personal and environmental factors influence the use of HPDs. Based on this study, personal and environmental factors need to be targeted for further research using ecological models to develop interventions that promote HPD use amongst workers.

  12. Intracellular Growth Is Dependent on Tyrosine Catabolism in the Dimorphic Fungal Pathogen Penicillium marneffei

    Science.gov (United States)

    Boyce, Kylie J.; McLauchlan, Alisha; Schreider, Lena; Andrianopoulos, Alex

    2015-01-01

    During infection, pathogens must utilise the available nutrient sources in order to grow while simultaneously evading or tolerating the host’s defence systems. Amino acids are an important nutritional source for pathogenic fungi and can be assimilated from host proteins to provide both carbon and nitrogen. The hpdA gene of the dimorphic fungus Penicillium marneffei, which encodes an enzyme which catalyses the second step of tyrosine catabolism, was identified as up-regulated in pathogenic yeast cells. As well as enabling the fungus to acquire carbon and nitrogen, tyrosine is also a precursor in the formation of two types of protective melanin; DOPA melanin and pyomelanin. Chemical inhibition of HpdA in P. marneffei inhibits ex vivo yeast cell production suggesting that tyrosine is a key nutrient source during infectious growth. The genes required for tyrosine catabolism, including hpdA, are located in a gene cluster and the expression of these genes is induced in the presence of tyrosine. A gene (hmgR) encoding a Zn(II)2-Cys6 binuclear cluster transcription factor is present within the cluster and is required for tyrosine induced expression and repression in the presence of a preferred nitrogen source. AreA, the GATA-type transcription factor which regulates the global response to limiting nitrogen conditions negatively regulates expression of cluster genes in the absence of tyrosine and is required for nitrogen metabolite repression. Deletion of the tyrosine catabolic genes in the cluster affects growth on tyrosine as either a nitrogen or carbon source and affects pyomelanin, but not DOPA melanin, production. In contrast to other genes of the tyrosine catabolic cluster, deletion of hpdA results in no growth within macrophages. This suggests that the ability to catabolise tyrosine is not required for macrophage infection and that HpdA has an additional novel role to that of tyrosine catabolism and pyomelanin production during growth in host cells. PMID:25812137

  13. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  14. Virtual MIMO Beamforming and Device Pairing Enabled by Device-to-Device Communications for Multidevice Networks

    Directory of Open Access Journals (Sweden)

    Yeonjin Jeong

    2017-01-01

    Full Text Available We consider a multidevice network with asymmetric antenna configurations which supports not only communications between an access point and devices but also device-to-device (D2D communications for the Internet of things. For the network, we propose the transmit and receive beamforming with the channel state information (CSI for virtual multiple-input multiple-output (MIMO enabled by D2D receive cooperation. We analyze the sum rate achieved by a device pair in the proposed method and identify the strategies to improve the sum rate of the device pair. We next present a distributed algorithm and its equivalent algorithm for device pairing to maximize the throughput of the multidevice network. Simulation results confirm the advantages of the transmit CSI and D2D cooperation as well as the validity of the distributive algorithm.

  15. Release strategies for making transferable semiconductor structures, devices and device components

    Science.gov (United States)

    Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J

    2014-11-25

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  16. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    Science.gov (United States)

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  17. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  18. Anti-early pregnancy by PDT

    Science.gov (United States)

    Ding, Ai-Hua; Chen, Hui-Ling

    1993-03-01

    The effect of laser on anti-early pregnancy in rabbits showed that laser in combination with HPD could induce necrosis of blastocysts and complete absorption. The anti-fertility efficiency of the combined treatment was more effective than that of the He-Ne laser or the HPD treatment alone. The fluorescence spectrum of HPD determined by PNQ3 showed that its affinity to embryonic tissue was about 4 times greater than that to uterine tissue. This may underlie the mechanisms of anti-early pregnancy of the laser. The operation of artificial abortion is a routine method to terminate early pregnancy. Though it is simple and easy, its syndrome and complications can not be absolutely avoided. Many antifertility drugs have been reported, however, they often bring in general reaction. Our present work is to explore a new way of anti-early pregnancy in rabbits by means of the light inhibitory and light sensitive effects of laser. It is a quite safe and painless treatment without expanding and scraping of the uterus.

  19. Temporal microbiota changes of high-protein diet intake in a rat model.

    Science.gov (United States)

    Mu, Chunlong; Yang, Yuxiang; Luo, Zhen; Zhu, Weiyun

    2017-10-01

    Alterations of specific microbes serve as important indicators that link gut health with specific diet intake. Although a six-week high-protein diet (45% protein) upregulates the pro-inflammatory response and oxidative stress in colon of rats, the dynamic alteration of gut microbiota remains unclear. To dissect temporal changes of microbiota, dynamic analyses of fecal microbiota were conducted using a rat model. Adult rats were fed a normal-protein diet or an HPD for 6 weeks, and feces collected at different weeks were used for microbiota and metabolite analysis. The structural alteration of fecal microbiota was observed after 4 weeks, especially for the decreased appearance of bands related to Akkermansia species. HPD increased numbers of Escherichia coli while decreased Akkermansia muciniphila, Bifidobacterium, Prevotella, Ruminococcus bromii, and Roseburia/Eubacterium rectale (P protein diet. HPD also decreased the copies of genes encoding butyryl-CoA:acetate CoA-transferase and Prevotella-associated methylmalonyl-CoA decarboxylase α-subunit (P high-protein diet. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. HADRON CALORIMETER (HCAL)

    CERN Multimedia

    A. Skuja

    HCAL installation and commissioning is approaching completion. Work continues on commissioning of HE-, HF- and the minus wheels of HO. We expect that all commissioning will be completed by mid-March. HCAL commissioning is interleaved with integration of HCAL and the Global Calorimeter Trigger (GCT). HCAL is attempting to take data using the HPD self-trigger as part of the GCT trigger path. Initial attempts in mid-February have not succeeded. Work continues on HCAL and the GCT. HPD lifetimes at 4 Tesla are being measured in Princeton. After more than a month of testing in a 4 Tesla field there are no sur¬prises. As the lifetime measurements proceed, the HPD response at intermediate fields of 1 Tesla will be verified and analyzed. Work also continues on HCAL calibration and DCS/DSS at Point 5. More details for some of the subsystems are presented in what follows. HE HE plus The cooling system of HE+ is functional now. The HE+ final connections to the LV system are complete. LV and HV tests to ev...

  1. Hostility and hearing protection behavior: the mediating role of personal beliefs and low frustration tolerance.

    Science.gov (United States)

    Rabinowitz, S; Melamed, S; Feiner, M; Weisberg, E; Ribak, J

    1996-10-01

    The authors examined whether hostility would negatively be associated with occupational health behavior, namely, the use of hearing protection devices (HPDs). Also examined as possible mediators were the protection motivation theory (PMT) components and low frustration tolerance (LFT). Participants were 226 male industrial workers, all exposed to potentially hearing-damaging noise. Hostility was negatively related to HPD use. It moderately correlated with the PMT components: negatively with perceived susceptibility, severity, effectiveness, and self-efficacy and positively with perceived barriers. Hostility correlated highly with LFT. Regression analyses confirmed the mediating role of perceived barriers, low self-efficacy, and LFT in the negative relationship between hostility and the use of HPDs. Thus, intrapsychic characteristics of hostile people may be significant for hearing protection behavior.

  2. Metabolic and mitochondrial dysfunction in early mouse embryos following maternal dietary protein intervention.

    Science.gov (United States)

    Mitchell, Megan; Schulz, Samantha L; Armstrong, David T; Lane, Michelle

    2009-04-01

    Dietary supply of nutrients, both periconception and during pregnancy, influence the growth and development of the fetus and offspring and their health into adult life. Despite the importance of research efforts surrounding the developmental origins of health and disease hypothesis, the biological mechanisms involved remain elusive. Mitochondria are of major importance in the oocyte and early embryo, particularly as a source of ATP generation, and perturbations in their function have been related to reduced embryo quality. The present study examined embryo development following periconception exposure of females to a high-protein diet (HPD) or a low-protein diet (LPD) relative to a medium-protein diet (MPD; control), and we hypothesized that perturbed mitochondrial metabolism in the mouse embryo may be responsible for the impaired embryo and fetal development reported by others. Although the rate of development to the blastocyst stage did not differ between diets, both the HPD and LPD reduced the number of inner cell mass cells in the blastocyst-stage embryo. Furthermore, mitochondrial membrane potential was reduced and mitochondrial calcium levels increased in the 2-cell embryo. Embryos from HPD females had elevated levels of reactive oxygen species and ADP concentrations, indicative of metabolic stress and, potentially, the uncoupling of oxidative phosphorylation, whereas embryos from LPD females had reduced mitochondrial clustering around the nucleus, suggestive of an overall quietening of metabolism. Thus, although periconception dietary supply of different levels of protein is permissive of development, mitochondrial metabolism is altered in the early embryo, and the nature of the perturbation differs between HPD and LPD exposure.

  3. Phylodynamic and Genetic Diversity of Canine Parvovirus Type 2c in Taiwan

    Directory of Open Access Journals (Sweden)

    Yung-Cheng Lin

    2017-12-01

    Full Text Available Canine parvovirus type 2c (CPV-2c emerged in 2000 and is known for causing a more severe disease than other CPV-2 variants in puppies. In 2015, the emerging CPV-2c variant was isolated in Taiwan and it subsequently became the predominant variant. To trace the evolution of Taiwanese CPV-2c, we compared complete VP2 genes of CPV-2c from Taiwan and sequences obtained from GenBank. The evolutionary rate of CPV-2c was estimated to be 4.586 × 10−4 substitutions per site per year (95% highest posterior density (HPD was 3.284–6.076 × 10−4. The time to the most recent common ancestor (TMRCA dated to 1990 (95% HPD: 1984–1996 and 2011 (95% HPD: 2010–2013 for the CPV-2c variant and Taiwanese isolates, respectively. The CPV-2c variant isolated from Taiwan was clustered with CPV-2c from China. This phylogenetic clade began to branch off in approximately 2010 (95% HPD was 3.823–6.497. Notably, two unique mutations of Taiwanese CPV-2c were found, Q383R and P410L. In summary, this is the first report on the genome evolution of CPV-2c in Taiwan, revealing that this CPV-2c variant shares a common evolutionary origin with strains from China. The demographic history inferred by the Bayesian skyline plot showed that the effective population of CPV-2c increased until 2006 and then slowly declined until 2011.

  4. Meta-analysis of lamb birth weight as influenced by pregnancy nutrition of multiparous ewes.

    Science.gov (United States)

    Roca Fraga, Fernando J; Lagisz, Malgorzata; Nakagawa, Shinichi; Lopez-Villalobos, Nicolas; Blair, Hugh; Kenyon, Paul

    2018-02-28

    Across the literature there is large variation in lamb birth weight responses to changes in the ewe pregnancy nutrition. Much of this heterogeneity has been attributed to several factors inherent to each experiment, however, the relative contribution of these experimental factors has not yet been quantified. This meta-analysis aimed to systematically review the variation in lamb birth weight responses across nutritional studies involving adult multiparous ewes. Effect sizes for individual studies were estimated using the unbiased estimator Hedges' g, whereby, positive and negative values indicate heavier and lighter treatment lambs vs. controls, respectively. Heterogeneity varied between early-, mid- and late-pregnancy undernutrition studies (I2total [early-pregnancy] = 19.90%, I2total [mid-pregnancy] = 52.10%, I2total [late-pregnancy] = 68.70%). The small average effects for early- (0.04, Highest Posterior Density (HPD) interval = -0.22 , 0.28) and mid-pregnancy undernutrition (-0.15, HPD interval = -0.35 , 0.05) suggest that if farmers anticipate a potential feed shortage, ewes can be allowed to lose weight providing nutrition is resumed to adequate levels later in pregnancy. On the contrary, late-pregnancy undernutrition was associated with a significant decrease in lamb birth weight (-0.72, HPD interval = -0.86 , -0.55). Thus, management practices should focus on ensuring adequate nutrition in late-pregnancy. Increasing lamb birth weight could be possible by feeding ewes above their pregnancy maintenance requirement (0.23, HPD interval = 0.002 , 0.48), though the number of studies is limited and further research is needed.

  5. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  6. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  7. Fabrication, performance, and figure metrology of epoxy-replicated aluminum foils for hard x-ray focusing multilayer-coated segmented conical optics

    DEFF Research Database (Denmark)

    Jimenez-Garate, M.A.; Craig, W.W.; Hailey, C.J.

    2000-01-01

    We fabricated x-ray mirrors for hard x-ray (greater than or equal to 10 keV) telescopes using multilayer coatings and an improved epoxy-replicated aluminum foil (ERAF) nonvacuum technology. The ERAF optics have similar to1 arcmin axial figure half-power diameter (HPD) and passed environmental...... telescope HPD, we designed a figure metrology system and a new mounting technique. We describe a cylindrical metrology system built for fast axial and roundness figure measurement of hard x-ray conical optics. These developments lower cost and improve the optics performance of the HEFT (high-energy focusing...

  8. Selection of performance-tested young bulls and indirect responses in commercial beef cattle herds on pasture and in feedlots.

    Science.gov (United States)

    Raidan, Fernanda S S; Santos, Dalinne C C; Moraes, Mariana M; Araújo, Andresa E M; Ventura, Henrique T; Bergmann, José A G; Turra, Eduardo M; Toral, Fabio L B

    2016-11-09

    Central testing is used to select young bulls which are likely to contribute to increased net income of the commercial beef cattle herd. We present genetic parameters for growth and reproductive traits on performance-tested young bulls and commercial animals that are raised on pasture and in feedlots. Records on young bulls and heifers in performance tests or commercial herds were used. Genetic parameters for growth and reproductive traits were estimated. Correlated responses for commercial animals when selection was applied on performance-tested young bulls were computed. The 90% highest posterior density (HPD90) intervals for heritabilities of final weight (FW), average daily gain (ADG) and scrotal circumference (SC) ranged from 0.41 to 0.49, 0.23 to 0.30 and 0.47 to 0.57, respectively, for performance-tested young bulls on pasture, from 0.45 to 0.60, 0.20 to 0.32 and 0.56 to 0.70, respectively, for performance-tested young bulls in feedlots, from 0.29 to 0.33, 0.14 to 0.18 and 0.35 to 0.45, respectively, for commercial animals on pasture, and from 0.24 to 0.44, 0.13 to 0.24 and 0.35 to 0.57 respectively, for commercial animals in feedlots. The HPD90 intervals for genetic correlations of FW, ADG and SC in performance-tested young bulls on pasture (feedlots) with FW, ADG and SC in commercial animals on pasture (feedlots) ranged from 0.86 to 0.96 (0.83 to 0.94), 0.78 to 0.90 (0.40 to 0.79) and from 0.92 to 0.97 (0.50 to 0.83), respectively. Age at first calving was genetically related to ADG (HPD90 interval = -0.48 to -0.06) and SC (HPD90 interval = -0.41 to -0.05) for performance-tested young bulls on pasture, however it was not related to ADG (HPD90 interval = -0.29 to 0.10) and SC (HPD90 interval = -0.35 to 0.13) for performance-tested young bulls in feedlots. Heritabilities for growth and SC are higher for performance-tested young bulls than for commercial animals. Evaluating and selecting for increased growth and SC on performance-tested young bulls is

  9. Medical Devices; General Hospital and Personal Use Devices; Classification of the Ultraviolet Radiation Chamber Disinfection Device. Final order.

    Science.gov (United States)

    2015-11-20

    The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  10. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  11. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  12. High voltage semiconductor devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    2018-01-23

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias. The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.

  13. Process control device

    International Nuclear Information System (INIS)

    Hayashi, Toshifumi; Kobayashi, Hiroshi.

    1994-01-01

    A process control device comprises a memory device for memorizing a plant operation target, a plant state or a state of equipments related with each other as control data, a read-only memory device for storing programs, a plant instrumentation control device or other process control devices, an input/output device for performing input/output with an operator, and a processing device which conducts processing in accordance with the program and sends a control demand or a display demand to the input/output device. The program reads out control data relative to a predetermined operation target, compares and verify them with actual values to read out control data to be a practice premise condition which is further to be a practice premise condition if necessary, thereby automatically controlling the plant or requiring or displaying input. Practice presuming conditions for the operation target can be examined succesively in accordance with the program without constituting complicated logical figures and AND/OR graphs. (N.H.)

  14. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  15. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  16. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  17. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  18. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood mixing devices and blood weighing devices. 864.9195 Section 864.9195 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That...

  19. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  20. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  1. Radioactive waste processing device

    International Nuclear Information System (INIS)

    Inaguma, Masahiko; Takahara, Nobuaki; Hara, Satomi.

    1996-01-01

    In a processing device for filtering laundry liquid wastes and shower drains incorporated with radioactive materials, a fiber filtration device is disposed and an activated carbon filtration device is also disposed subsequent to the fiber filtration device. In addition, a centrifugal dewatering device is disposed for dewatering spent granular activated carbon in the activated carbon filtration device, and a minute filtering device is disposed for filtering the separated dewatering liquid. Filtrates filtered by the minute filtration device are recovered in a collecting tank. Namely, at first, suspended solid materials in laundry liquid wastes and shower drains are captured, and then, ingredients concerning COD are adsorbed in the activated carbon filtration device. The radioactive liquid wastes of spent granular activated carbon in the activated carbon filtration device are reduced by dewatering them by the centrifugal dewatering device, and then the granular activated carbon is subjected to an additional processing. Further, it is separated by filtration using the minute filtration device and removed as cakes. Since the filtrates are recovered to the collecting tank and filtered again, the water quality of the drains is not degraded. (N.H.)

  2. Normal protein intake is required for body weight loss and weight maintenance, and elevated protein intake for additional preservation of resting energy expenditure and fat free mass.

    Science.gov (United States)

    Soenen, Stijn; Martens, Eveline A P; Hochstenbach-Waelen, Ananda; Lemmens, Sofie G T; Westerterp-Plantenga, Margriet S

    2013-05-01

    Energy-restricted high-protein diets (HPDs) have shown favorable results for body weight (BW) management, yet studies differ in their outcomes depending on the dietary protein content. Our objective was to determine the effects of dietary protein content on BW loss-related variables during a 6-mo energy restriction with the use of diets containing protein at the level of requirement [normal-protein diet (NPD), 0.8 g · kg BW(-1) (.) d(-1)] and above (HPD, 1.2 g · kg BW(-1) (.) d(-1)). In overweight and obese participants (24 men and 48 women), BW, body composition, and metabolic responses were assessed before and after subsequent energy intakes of 100, 33, and 67% of the original individual daily energy requirements. Protein intake was consistent in the NPD (0.8 ± 0.3 g · kg BW(-1) (.) d(-1)) and HPD (1.2 ± 0.3 g · kg BW(-1) (.) d(-1)) groups throughout the study (P body fat mass similarly decreased in the NPD and HPD groups (P initial sparing effect of FFM and lowering of DBP.

  3. High heat flux device of thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo.

    1994-01-01

    The present invention provides an equipments for high heat flux device (divertor) of a thermonuclear device, which absorbs thermal deformation during operation, has a high installation accuracy, and sufficiently withstands for thermal stresses. Namely, a heat sink member is joined to a structural base. Armour tiles are joined on the heat sink member. Cooling pipes are disposed between the heat sink member and the armour tiles. With such a constitution, the heat sink member using a highly heat conductive material having ductility, such as oxygen free copper, the cooling pipes using a material having excellent high temperature resistance and excellent elongation, such as aluminum-dispersed reinforced copper, and the armour tiles are completely joined on the structural base. Therefore, when thermal deformation tends to cause in the high heat flux device such as a divertor, cooling pipes cause no plastic deformation because of their high temperature resistance, but the heat sink member such as a oxygen free copper causes plastic deformation to absorb thermal deformation. As a result, the high heat flux device such as a divertor causes no deformation. (I.S.)

  4. Repairing method and device for thermonuclear device

    International Nuclear Information System (INIS)

    Sakurai, Akiko; Masumoto, Hiroshi; Tachikawa, Nobuo.

    1995-01-01

    The present invention provides a method of and a device for repairing a first wall and a divertor disposed in a vacuum vessel of a thermonuclear device. Namely, an armour tile of the divertor secured, by a brazing material, in a vacuum vessel of the thermonuclear device in which high temperature plasmas of deuterium and tritium are confined to cause fusion reaction is induction-heated or heated by microwaves to melt the brazing material. Only the armour tile is thus exchanged by its attachment/detachment. This device comprises, in the vacuum vessel, an armour tile attaching/detaching manipulator and a repairing manipulator comprising a heating manipulator having induction heating coils at the top end thereof. Induction heating coils are connected to an AC power source. According to the present invention, the armour tile is exchanged without taking the divertor out of the vacuum vessel. Therefore, cutting of a divertor cooling tube for taking the divertor out of the vacuum vessel and re-welding of the divertor for attaching it to the vacuum vessel again are no more necessary. (I.S.)

  5. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  6. Probing absorption of deuterium into palladium cathodes during D2O electrolysis with an in situ electrochemical microbalance technique

    International Nuclear Information System (INIS)

    Oyama, Noboru; Yamamoto, Nobushige; Hatozaki, Osamu; Ohsaka, Takeo

    1990-01-01

    The in situ observation of the absorption of deuterium (or hydrogen) into the Pd cathode during D 2 O (or H 2 O) electrolysis was made by an electrochemical microbalance technique which is based on the quartz-crystal electrode. The resonant frequency of the Pd-coated quartz-crystal electrode decreased with increasing amount of charge passed during electrolysis, and the frequency change for the D 2 O electrolysis was about twice that for the H 2 O electrolysis. The atom ratios of H/Pd and D/Pd of the H-Pd and D-Pd compounds resulting from the electrolysis were estimated to be 0.59 and 0.57, respectively. (author)

  7. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  8. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-06-10

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... certain electronic devices, including wireless communication devices, portable music and data processing...

  9. Novel Concepts for Device to Device Communication using Network Coding

    DEFF Research Database (Denmark)

    Pahlevani, Peyman; Hundebøll, Martin; Pedersen, Morten Videbæk

    2014-01-01

    Device-to-device communication is currently a hot research topic within 3GPP. Even though D2D communication has been part of previous ad hoc, meshed and sensor networks proposals, the main contribution by 3GPP is that the direct communication among two devices is carried out over a dynamically as...

  10. Device configuration-management system

    International Nuclear Information System (INIS)

    Nowell, D.M.

    1981-01-01

    The Fusion Chamber System, a major component of the Magnetic Fusion Test Facility, contains several hundred devices which report status to the Supervisory Control and Diagnostic System for control and monitoring purposes. To manage the large number of diversity of devices represented, a device configuration management system was required and developed. Key components of this software tool include the MFTF Data Base; a configuration editor; and a tree structure defining the relationships between the subsystem devices. This paper will describe how the configuration system easily accomodates recognizing new devices, restructuring existing devices, and modifying device profile information

  11. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  12. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  13. Device-independent randomness amplification with a single device

    International Nuclear Information System (INIS)

    Plesch, Martin; Pivoluska, Matej

    2014-01-01

    Expansion and amplification of weak randomness with untrusted quantum devices has recently become a very fruitful topic of research. Here we contribute with a procedure for amplifying a single weak random source using tri-partite GHZ-type entangled states. If the quality of the source reaches a fixed threshold R=log 2 ⁡(10), perfect random bits can be produced. This technique can be used to extract randomness from sources that can't be extracted neither classically, nor by existing procedures developed for Santha–Vazirani sources. Our protocol works with a single fault-free device decomposable into three non-communicating parts, that is repeatedly reused throughout the amplification process. - Highlights: • We propose a protocol for device independent randomness amplification. • Our protocol repeatedly re-uses a single device decomposable into three parts. • Weak random sources with min-entropy rate greater than 1/4 log 2 ⁡(10) can be amplified. • Security against all-quantum adversaries is achieved

  14. Smart portable rehabilitation devices

    Directory of Open Access Journals (Sweden)

    Leahey Matt

    2005-07-01

    Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

  15. Smart portable rehabilitation devices.

    Science.gov (United States)

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-07-12

    The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

  16. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Incore instrumentation device

    International Nuclear Information System (INIS)

    Fujita, Kazuhiko.

    1996-01-01

    A position of a detector is detected by a driving device, and the detected values are sampled by a newly disposed central processing unit for sampling the detected values depending on the sampling position of the detected values. Since the sampling position of the detected values is detected by the driving device, the sampling position for the detection values does not rely on the speed of the driving motor of the driving device. The load on the central processing device for controlling the device is lowered by newly disposing the central processing unit for sampling detected values. When the values for the position of the detector counted after conversion to digital values reach the digital values corresponding to the detection value sampling position outputted from the central processing unit for controlling the device, a counted value comparison circuit causes the central processing unit for controlling the device to sample the detection values outputted from the detector. Then, the processing speed can be increased without interruption processings, which can save the central processing unit for sampling detection values. In addition, software can be simplified and loads can be lowered. (N.H.)

  18. Inspection device in liquid

    International Nuclear Information System (INIS)

    Nagaoka, Etsuo.

    1996-01-01

    The present invention provides an inspection device in PWR reactor core in which inspection operations are made efficient by stabilizing a posture of the device in front-to-back, vertical and left-to-right directions by a simple structure. When the device conducts inspection while running in liquid, the front and the back directions of the device main body are inspected using a visual device while changing the posture by operating a front-to-back direction propulsion device and a right-to-left direction propulsion device, and a vertical direction propulsion device against to rolling, pitching and yawing of the device main body. In this case, a spherical magnet moves freely in the gravitational direction in a vibration-damping fluid in a non-magnetic spherical shell following the change of the posture of the device main body, in which the vibrations due to the movement of the spherical magnet is settled by the vibration-damping fluid thereby stabilizing the posture of the device main body. At a typical inspection posture, the settling effect is enhanced by the attraction force between the spherical magnets in the spherical shell and each of magnetic force-attracted magnetic members disposed to the outer circumference of the shell, and the posture of the device main body can be confirmed in front-to-back, right-to-left and vertical directions by each of the posture confirming magnetic sensors. (N.H.)

  19. 78 FR 16865 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-03-19

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... certain electronic devices, including wireless communication devices, portable music and data processing...

  20. Predistortion control device and method, assembly including a predistortion control device

    NARCIS (Netherlands)

    Kokkeler, Andre B.J.

    2003-01-01

    A predistortion control device (1). The device has a first predistortion control input connectable to a power amplifier output (21); a second predistortion control input (11) connectable to a signal contact of a predistortion device; and a predistortion control output (12) connectable to a control

  1. 78 FR 1247 - Certain Electronic Devices, Including Wireless Communication Devices, Tablet Computers, Media...

    Science.gov (United States)

    2013-01-08

    ... Wireless Communication Devices, Tablet Computers, Media Players, and Televisions, and Components Thereof... devices, including wireless communication devices, tablet computers, media players, and televisions, and... wireless communication devices, tablet computers, media players, and televisions, and components thereof...

  2. Initiation devices, initiation systems including initiation devices and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Michael A.; Condit, Reston A.; Rasmussen, Nikki; Wallace, Ronald S.

    2018-04-10

    Initiation devices may include at least one substrate, an initiation element positioned on a first side of the at least one substrate, and a spark gap electrically coupled to the initiation element and positioned on a second side of the at least one substrate. Initiation devices may include a plurality of substrates where at least one substrate of the plurality of substrates is electrically connected to at least one adjacent substrate of the plurality of substrates with at least one via extending through the at least one substrate. Initiation systems may include such initiation devices. Methods of igniting energetic materials include passing a current through a spark gap formed on at least one substrate of the initiation device, passing the current through at least one via formed through the at least one substrate, and passing the current through an explosive bridge wire of the initiation device.

  3. High energy devices versus low energy devices in orthopedics treatment modalities

    Science.gov (United States)

    Schultheiss, Reiner

    2003-10-01

    The orthopedic consensus group defined in 1997 the 42 most likely relevant parameters of orthopedic shock wave devices. The idea of this approach was to correlate the different clinical outcomes with the physical properties of the different devices with respect to their acoustical waves. Several changes in the hypothesis of the dose effect relationship have been noticed since the first orthopedic treatments. The relation started with the maximum pressure p+, followed by the total energy, the energy density; and finally the single treatment approach using high, and then the multiple treatment method using low energy. Motivated by the reimbursement situation in Germany some manufacturers began to redefine high and low energy devices independent of the treatment modality. The OssaTron as a high energy, single treatment electro hydraulic device gained FDA approval as the first orthopedic ESWT device for plantar fasciitis and, more recently, for lateral epicondylitis. Two low energy devices have now also gained FDA approval based upon a single treatment. Comparing the acoustic data, differences between the OssaTron and the other devices are obvious and will be elaborated upon. Cluster analysis of the outcomes and the acoustical data are presented and new concepts will be suggested.

  4. 77 FR 70464 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-11-26

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... wireless communication devices, portable music and data processing devices, and tablet computers, by reason...

  5. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  6. 77 FR 60720 - Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-10-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data Processing Devices, and Tablet Computers... communication devices, portable music and data processing devices, and tablet computers, imported by Apple Inc...

  7. 78 FR 29672 - Cardiovascular Devices; Reclassification of External Counter-Pulsating Devices for Treatment of...

    Science.gov (United States)

    2013-05-21

    .... FDA-2013-N-0487] Cardiovascular Devices; Reclassification of External Counter- Pulsating Devices for... proposed rule (44 FR 13426, March 9, 1979), the Cardiovascular Device Classification Panel (the 1979 Panel... of Subjects in 21 CFR Part 870 Medical devices, Cardiovascular devices...

  8. Recoil transporter devices

    International Nuclear Information System (INIS)

    Madhavan, N.

    2005-01-01

    The study of sparsely produced nuclear reaction products in the direction of intense primary beam is a challenging task, the pursuit of which has given rise to the advent or several types of selective devices. These range from a simple parallel plate electrostatic deflector to state-of-the-art electromagnetic separators. There is no single device which can satisfy all the requirements of an ideal recoil transporter, simultaneously. An overview of such devices and their building blocks is presented, which may help in the proper choice of the device as per the experimental requirements. (author)

  9. Dietary variety is associated with larger meals in female rhesus monkeys.

    Science.gov (United States)

    Moore, Carla J; Michopoulos, Vasiliki; Johnson, Zachary P; Toufexis, Donna; Wilson, Mark E

    2013-07-02

    The complex, interacting influences on eating behavior and energy expenditure prevent elucidation of the causal role of any single factor in the current obesity epidemic. However, greater variety in the food supply, particularly in the form of highly palatable, energy-dense foods, has likely made a contribution. This study was undertaken to test the hypothesis that greater dietary variety is associated with greater caloric intake within individual meals consumed by free-feeding, socially-housed female rhesus monkeys. Meal patterns were assessed during two, two-week dietary phases. One phase consisted of a choice between a standard chow diet and a highly palatable diet (HPD). The other phase consisted of access to the chow only. Food intake for each subject was recorded continuously using previously validated, automated feeders, and a meal was defined based on a minimum kilocalorie requirement and a minimum inter-meal interval. During the choice condition, animals electively consumed mixed meals that incorporated both diets as well as other meals that consisted exclusively of a single diet - chow-only or HPD-only. Animals consumed the most calories per meal when the meal was comprised of both the chow and HPD, which differed in caloric density, flavor, and texture. Interestingly, however, there was no significant difference in the amount of calories consumed as HPD-only meals in the choice condition compared to meals in the chow-only, no choice condition, suggesting consumption of a single food during a meal, regardless of palatability, provides a constant sensory experience that may lead to more rapid habituation and subsequent meal cessation. Additionally, during the dietary choice condition, animals consumed fewer calories in the form of chow-only meals. Thus, the present results suggest that limiting dietary variety, regardless of palatability, may be a useful strategy for weight loss in overweight and obese individuals by reducing caloric intake within

  10. Energy aAnalysis and Kinetics of Mint Leaves Dehydration Using Vibro-Fluidized Bed Heat Pump Dryer

    Directory of Open Access Journals (Sweden)

    S. M Ataei Ardestani

    2015-03-01

    Full Text Available Fluidized bed dryers have not yet been used for drying products such as mint leaves. This could be due to high porosity and low mechanical resistance resulting in poor quality of fluidization. Applying vibration has been recommended to overcome problems such as channeling and defluidization, and hence improving the fluidization quality. In this research, a laboratory scale vibro-fluidized bed heat pump dryer was designed and constructed for drying mint leaves. The experiments were conducted at vibration frequency of 80 Hz and amplitude of 3 mm. The velocity and temperature of the inlet air was controlled by an automatic control system. Experiments were carried out at 40, 50 and 60 °C, and two methods: heat pump drying (HPD and non-heat pump drying (NHPD. The results revealed that drying process primarily occurred in the falling rate period. Effective moisture diffusivity of the samples increased with increase in drying air temperature and varied from 4.26656×10-11 to 2.95872×10-10 m2 s-1 for the HPD method, and 3.71918×10-11 to 1.29196×10-10 m2 s-1 for the NHPD method and was within the reported range of 10-9 to 10-11 m2 s-1 for drying of food materials. The activation energy was determined to be 84 kJ mol-1 for the HPD and 54.34 kJ mol-1 for the NHPD, both have very good agreement with the results of other investigators. The coefficient of performance and specific moisture evaporation rate showed the acceptable performance of the heat pump system. Moreover, the energy consumption of the dryer for the NHPD method was more than the HPD method.

  11. Multiplexed charge-locking device for large arrays of quantum devices

    Energy Technology Data Exchange (ETDEWEB)

    Puddy, R. K., E-mail: rkp27@cam.ac.uk; Smith, L. W; Chong, C. H.; Farrer, I.; Griffiths, J. P.; Ritchie, D. A.; Smith, C. G. [Cavendish Laboratory, University of Cambridge, Cambridge CB3 0HE (United Kingdom); Al-Taie, H.; Kelly, M. J. [Cavendish Laboratory, University of Cambridge, Cambridge CB3 0HE (United Kingdom); Centre for Advanced Photonics and Electronics, Electrical Engineering Division, Department of Engineering, 9 J. J. Thomson Avenue, University of Cambridge, Cambridge CB3 0FA (United Kingdom); Pepper, M. [Department of Electronic and Electrical Engineering, University College London, WC1E 7JE (United Kingdom)

    2015-10-05

    We present a method of forming and controlling large arrays of gate-defined quantum devices. The method uses an on-chip, multiplexed charge-locking system and helps to overcome the restraints imposed by the number of wires available in cryostat measurement systems. The device architecture that we describe here utilises a multiplexer-type scheme to lock charge onto gate electrodes. The design allows access to and control of gates whose total number exceeds that of the available electrical contacts and enables the formation, modulation and measurement of large arrays of quantum devices. We fabricate such devices on n-type GaAs/AlGaAs substrates and investigate the stability of the charge locked on to the gates. Proof-of-concept is shown by measurement of the Coulomb blockade peaks of a single quantum dot formed by a floating gate in the device. The floating gate is seen to drift by approximately one Coulomb oscillation per hour.

  12. MemFlash device: floating gate transistors as memristive devices for neuromorphic computing

    Science.gov (United States)

    Riggert, C.; Ziegler, M.; Schroeder, D.; Krautschneider, W. H.; Kohlstedt, H.

    2014-10-01

    Memristive devices are promising candidates for future non-volatile memory applications and mixed-signal circuits. In the field of neuromorphic engineering these devices are especially interesting to emulate neuronal functionality. Therefore, new materials and material combinations are currently investigated, which are often not compatible with Si-technology processes. The underlying mechanisms of the device often remain unclear and are paired with low device endurance and yield. These facts define the current most challenging development tasks towards a reliable memristive device technology. In this respect, the MemFlash concept is of particular interest. A MemFlash device results from a diode configuration wiring scheme of a floating gate transistor, which enables the persistent device resistance to be varied according to the history of the charge flow through the device. In this study, we investigate the scaling conditions of the floating gate oxide thickness with respect to possible applications in the field of neuromorphic engineering. We show that MemFlash cells exhibit essential features with respect to neuromorphic applications. In particular, cells with thin floating gate oxides show a limited synaptic weight growth together with low energy dissipation. MemFlash cells present an attractive alternative for state-of-art memresitive devices. The emulation of associative learning is discussed by implementing a single MemFlash cell in an analogue circuit.

  13. MemFlash device: floating gate transistors as memristive devices for neuromorphic computing

    International Nuclear Information System (INIS)

    Riggert, C; Ziegler, M; Kohlstedt, H; Schroeder, D; Krautschneider, W H

    2014-01-01

    Memristive devices are promising candidates for future non-volatile memory applications and mixed-signal circuits. In the field of neuromorphic engineering these devices are especially interesting to emulate neuronal functionality. Therefore, new materials and material combinations are currently investigated, which are often not compatible with Si-technology processes. The underlying mechanisms of the device often remain unclear and are paired with low device endurance and yield. These facts define the current most challenging development tasks towards a reliable memristive device technology. In this respect, the MemFlash concept is of particular interest. A MemFlash device results from a diode configuration wiring scheme of a floating gate transistor, which enables the persistent device resistance to be varied according to the history of the charge flow through the device. In this study, we investigate the scaling conditions of the floating gate oxide thickness with respect to possible applications in the field of neuromorphic engineering. We show that MemFlash cells exhibit essential features with respect to neuromorphic applications. In particular, cells with thin floating gate oxides show a limited synaptic weight growth together with low energy dissipation. MemFlash cells present an attractive alternative for state-of-art memresitive devices. The emulation of associative learning is discussed by implementing a single MemFlash cell in an analogue circuit. (paper)

  14. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a...

  15. Electronic security device

    Science.gov (United States)

    Eschbach, Eugene A.; LeBlanc, Edward J.; Griffin, Jeffrey W.

    1992-01-01

    The present invention relates to a security device having a control box (12) containing an electronic system (50) and a communications loop (14) over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system (50) and a detection module (72) capable of registering changes in the voltage and phase of the signal transmitted over the loop.

  16. Electronic security device

    International Nuclear Information System (INIS)

    Eschbach, E.A.; LeBlanc, E.J.; Griffin, J.W.

    1992-01-01

    The present invention relates to a security device having a control box containing an electronic system and a communications loop over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system and a detection module capable of registering changes in the voltage and phase of the signal transmitted over the loop. 11 figs

  17. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  18. Three fundamental devices in one: a reconfigurable multifunctional device in two-dimensional WSe2

    Science.gov (United States)

    Dhakras, Prathamesh; Agnihotri, Pratik; Lee, Ji Ung

    2017-06-01

    The three pillars of semiconductor device technologies are (1) the p-n diode, (2) the metal-oxide-semiconductor field-effect transistor and (3) the bipolar junction transistor. They have enabled the unprecedented growth in the field of information technology that we see today. Until recently, the technological revolution for better, faster and more efficient devices has been governed by scaling down the device dimensions following Moore’s Law. With the slowing of Moore’s law, there is a need for alternative materials and computing technologies that can continue the advancement in functionality. Here, we describe a single, dynamically reconfigurable device that implements these three fundamental device functions. The device uses buried gates to achieve n- and p-channels and fits into a larger effort to develop devices with enhanced functionalities, including logic functions, over device scaling. As they are all surface conducting devices, we use one material parameter, the interface trap density of states, to describe the key figure-of-merit of each device.

  19. Devices, Distractions and Digital Literacy: "Bring Your Own Device" to Polytech

    Science.gov (United States)

    Drew, Leoni; Forbes, Dianne

    2017-01-01

    The purpose of this study is to investigate the ways polytechnic students use personal mobile devices to support their learning. This study used purposive sampling and mixed methods to generate data about student ownership and use of mobile digital devices within a single institution. Findings reveal patterns of device ownership, insights into how…

  20. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  1. Metallic spintronic devices

    CERN Document Server

    Wang, Xiaobin

    2014-01-01

    Metallic Spintronic Devices provides a balanced view of the present state of the art of metallic spintronic devices, addressing both mainstream and emerging applications from magnetic tunneling junction sensors and spin torque oscillators to spin torque memory and logic. Featuring contributions from well-known and respected industrial and academic experts, this cutting-edge work not only presents the latest research and developments but also: Describes spintronic applications in current and future magnetic recording devicesDiscusses spin-transfer torque magnetoresistive random-access memory (STT-MRAM) device architectures and modelingExplores prospects of STT-MRAM scaling, such as detailed multilevel cell structure analysisInvestigates spintronic device write and read optimization in light of spintronic memristive effectsConsiders spintronic research directions based on yttrium iron garnet thin films, including spin pumping, magnetic proximity, spin hall, and spin Seebeck effectsProposes unique solutions for ...

  2. Solar cell of 6.3% efficiency employing high deposition rate (8 nm/s) microcrystalline silicon photovoltaic layer

    Energy Technology Data Exchange (ETDEWEB)

    Sobajima, Yasushi; Nishino, Mitsutoshi; Fukumori, Taiga; Kurihara, Masanori; Higuchi, Takuya; Nakano, Shinya; Toyama, Toshihiko; Okamoto, Hiroaki [Department of Systems Innovation, Graduate School of Engineering Science, Osaka University, Toyonaka, Machikaneyama-cho 1-3, Osaka 560-8531 (Japan)

    2009-06-15

    Microcrystalline silicon ({mu}c-Si) films deposited at high growth rates up to 8.1 nm/s prepared by very-high-frequency-plasma-enhanced chemical vapor deposition (VHF-PECVD) at 18-24 Torr have been investigated. The relation between the deposition rates and input power revealed the depletion of silane. Under high-pressure deposition (HPD) conditions, the structural properties were improved. Furthermore, applying {mu}c-Si to n-i-p solar cells, short-circuit current density (J{sub SC}) was increased in accordance with the improvement of microstructure of i-layer. As a result, a conversion efficiency of 6.30% has been achieved employing the i-layer deposited at 8.1 nm/s under the HPD conditions. (author)

  3. Robust Covariance Estimators Based on Information Divergences and Riemannian Manifold

    Directory of Open Access Journals (Sweden)

    Xiaoqiang Hua

    2018-03-01

    Full Text Available This paper proposes a class of covariance estimators based on information divergences in heterogeneous environments. In particular, the problem of covariance estimation is reformulated on the Riemannian manifold of Hermitian positive-definite (HPD matrices. The means associated with information divergences are derived and used as the estimators. Without resorting to the complete knowledge of the probability distribution of the sample data, the geometry of the Riemannian manifold of HPD matrices is considered in mean estimators. Moreover, the robustness of mean estimators is analyzed using the influence function. Simulation results indicate the robustness and superiority of an adaptive normalized matched filter with our proposed estimators compared with the existing alternatives.

  4. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  5. Delay reduction in multi-hop device-to-device communication using network coding

    KAUST Repository

    Douik, Ahmed S.; Sorour, Sameh; Al-Naffouri, Tareq Y.; Yang, Hong-Chuan; Alouini, Mohamed-Slim

    2015-01-01

    This paper considers the problem of reducing the broadcast delay of wireless networks using instantly decodable network coding (IDNC) based device-to-device (D2D) communications. In D2D-enabled networks, devices help hasten the recovery of the lost

  6. Leaf Senescence, Root Morphology, and Seed Yield of Winter Oilseed Rape (Brassica napus L. at Varying Plant Densities

    Directory of Open Access Journals (Sweden)

    Ming Li

    2017-01-01

    Full Text Available In this study, the yield and yield components were studied using a conventional variety Zhongshuang 11 (ZS 11 and a hybrid variety Zhongyouza 12 (ZYZ 12 at varying plant densities. The increase in plant density led to an initial increase in seed yield and pod numbers per unit area, followed by a decrease. The optimal plant density was 58.5 × 104 plants ha−1 in both ZS 11 and ZYZ 12. The further researches on physiological traits showed a rapid decrease in the green leaf area index (GLAI and chlorophyll content and a remarkable increase in malondialdehyde content in high plant density (HPD population than did the low plant density (LPD population, which indicated the rapid leaf senescence. However, HPD had higher values in terms of pod area index (PAI, pod photosynthesis, and radiation use efficiency (RUE after peak anthesis. A significantly higher level of dry matter accumulation and nitrogen utilization efficiency were observed, which resulted in higher yield. HPD resulted in a rapid decrease in root morphological parameters (root length, root tips, root surface area, and root volume. These results suggested that increasing the plant density within a certain range was a promising option for high seed yield in winter rapeseed in China.

  7. Temperature indicating device

    International Nuclear Information System (INIS)

    Angus, J.P.; Salt, D.

    1988-01-01

    A temperature indicating device comprises a plurality of planar elements some undergoing a reversible change in appearance at a given temperature the remainder undergoing an irreversible change in appearance at a given temperature. The device is useful in indicating the temperature which an object has achieved as well as its actual temperature. The reversible change is produced by liquid crystal devices. The irreversible change is produced by an absorbent surface carrying substances e.g. waxes which melt at predetermined temperatures and are absorbed by the surface; alternatively paints may be used. The device is used for monitoring processes of encapsulation of radio active waste. (author)

  8. Thermal energy storage devices, systems, and thermal energy storage device monitoring methods

    Science.gov (United States)

    Tugurlan, Maria; Tuffner, Francis K; Chassin, David P.

    2016-09-13

    Thermal energy storage devices, systems, and thermal energy storage device monitoring methods are described. According to one aspect, a thermal energy storage device includes a reservoir configured to hold a thermal energy storage medium, a temperature control system configured to adjust a temperature of the thermal energy storage medium, and a state observation system configured to provide information regarding an energy state of the thermal energy storage device at a plurality of different moments in time.

  9. Simulations indicate that scores of lionfish (Pterois volitans) colonized the Atlantic Ocean.

    Science.gov (United States)

    Selwyn, Jason D; Johnson, John E; Downey-Wall, Alan M; Bynum, Adam M; Hamner, Rebecca M; Hogan, J Derek; Bird, Christopher E

    2017-01-01

    The invasion of the western Atlantic Ocean by the Indo-Pacific red lionfish ( Pterois volitans ) has had devastating consequences for marine ecosystems. Estimating the number of colonizing lionfish can be useful in identifying the introduction pathway and can inform policy decisions aimed at preventing similar invasions. It is well-established that at least ten lionfish were initially introduced. However, that estimate has not faced probabilistic scrutiny and is based solely on the number of haplotypes in the maternally-inherited mitochondrial control region. To rigorously estimate the number of lionfish that were introduced, we used a forward-time, Wright-Fisher, population genetic model in concert with a demographic, life-history model to simulate the invasion across a range of source population sizes and colonizing population fecundities. Assuming a balanced sex ratio and no Allee effects, the simulations indicate that the Atlantic population was founded by 118 (54-514, 95% HPD) lionfish from the Indo-Pacific, the Caribbean by 84 (22-328, 95% HPD) lionfish from the Atlantic, and the Gulf of Mexico by at least 114 (no upper bound on 95% HPD) lionfish from the Caribbean. Increasing the size, and therefore diversity, of the Indo-Pacific source population and fecundity of the founding population caused the number of colonists to decrease, but with rapidly diminishing returns. When the simulation was parameterized to minimize the number of colonists (high θ and relative fecundity), 96 (48-216, 95% HPD) colonists were most likely. In a more realistic scenario with Allee effects (e.g., 50% reduction in fecundity) plaguing the colonists, the most likely number of lionfish increased to 272 (106-950, 95% HPD). These results, in combination with other published data, support the hypothesis that lionfish were introduced to the Atlantic via the aquarium trade, rather than shipping. When building the model employed here, we made assumptions that minimize the number of

  10. EPICS GPIB device support

    International Nuclear Information System (INIS)

    Winans, J.

    1993-01-01

    A GPIB device support module is used to provide access to the operating parameters of a GPIB device. GPIB devices may be accessed via National Instruments 1014 cards or via Bitbus Universal Gateways. GPIB devices typically have many parameters, each of which may be thought of in terms of the standard types of database records available in EPICS. It is the job of the device support module designer to decide how the mapping of these parameters will be made to the available record types. Once this mapping is complete, the device support module may be written. The writing of the device support module consists primarily of the construction of a parameter table. This table is used to associate the database record types with the operating parameters of the GPIB instrument. Other aspects of module design include the handling of SRQ events and errors. SRQ events are made available to the device support module if so desired. The processing of an SRQ event is completely up to the designer of the module. They may be ignored, tied to event based record processing, or anything else the designer wishes. Error conditions may be handled in a similar fashion

  11. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    Energy Technology Data Exchange (ETDEWEB)

    Lijuan Zou

    2003-08-05

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm{sup 2}, the optimal radiance R could reach 0.38 mW/cm{sup 2}, and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be {approx} 10{sup -5} cm{sup 2}/Vs and {approx} 10{sup -4} cm{sup 2}/Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces.

  12. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    International Nuclear Information System (INIS)

    Lijuan Zou

    2003-01-01

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm 2 , the optimal radiance R could reach 0.38 mW/cm 2 , and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be ∼ 10 -5 cm 2 /Vs and ∼ 10 -4 cm 2 /Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces

  13. 77 FR 51571 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-08-24

    ... Music and Data Processing Devices, Computers, and Components Thereof; Notice of Receipt of Complaint... complaint entitled Wireless Communication Devices, Portable Music and Data Processing Devices, Computers..., portable music and data processing devices, computers, and components thereof. The complaint names as...

  14. Integrated control rod monitoring device

    International Nuclear Information System (INIS)

    Saito, Katsuhiro

    1997-01-01

    The present invention provides a device in which an entire control rod driving time measuring device and a control rod position support device in a reactor building and a central control chamber are integrated systematically to save hardwares such as a signal input/output device and signal cables between boards. Namely, (1) functions of the entire control rod driving time measuring device for monitoring control rods which control the reactor power and a control rod position indication device are integrated into one identical system. Then, the entire devices can be made compact by the integration of the functions. (2) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated in a central operation board and a board in the site. Then, the place for the installation of them can be used in common in any of the cases. (3) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated to one identical system to save hardware to be used. Then, signal input/output devices and drift branching panel boards in the site and the central operation board can be saved, and cables for connecting both of the boards is no more necessary. (I.S.)

  15. 76 FR 45860 - In the Matter of Certain Electronic Devices, Including Wireless Communication Devices, Portable...

    Science.gov (United States)

    2011-08-01

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... electronic devices, including wireless communication devices, portable music and data processing devices, and...''). The complaint further alleges that an industry in the United States exists or is in the process of...

  16. Medical devices; exemption from premarket notification; class II devices; wheelchair elevator. Final order.

    Science.gov (United States)

    2013-03-04

    The Food and Drug Administration (FDA) is publishing an order granting a petition requesting exemption from premarket notification requirements for wheelchair elevator devices commonly known as inclined platform lifts and vertical platform lifts. These devices are used to provide a means for a person with a mobility impairment caused by injury or other disease to move from one level to another, usually in a wheelchair. This order exempts wheelchair elevators, class II devices, from premarket notification and establishes conditions for exemption for this device that will provide a reasonable assurance of the safety and effectiveness of the device without submission of a premarket notification (510(k)). This exemption from 510(k), subject to these conditions, is immediately in effect for wheelchair elevators. All other devices classified under FDA's wheelchair elevator regulations, including attendant-operated stair climbing devices for wheelchairs and portable platform lifts, continue to require submission of 510(k)s. FDA is publishing this order in accordance with the section of the Food, Drug, and Cosmetic Act (the FD&C Act) permitting the exemption of a device from the requirement to submit a 510(k).

  17. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  18. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2018-06-05

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  19. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  20. Fuel pattern recognition device

    International Nuclear Information System (INIS)

    Sato, Tomomi.

    1995-01-01

    The device of the present invention monitors normal fuel exchange upon fuel exchanging operation carried out in a reactor of a nuclear power plant. Namely, a fuel exchanger is movably disposed to the upper portion of the reactor and exchanges fuels. An exclusive computer receives operation signals of the fuel exchanger during operation as inputs, and outputs reactor core fuel pattern information signals to a fuel arrangement diagnosis device. An underwater television camera outputs image signals of a fuel pattern in the reactor core to an image processing device. If there is any change in the image signals for the fuel pattern as a result of the fuel exchange operation of the fuel exchanger, the image processing device outputs the change as image signals to the fuel pattern diagnosis device. The fuel pattern diagnosis device compares the pattern information signals from the exclusive computer with the image signals from the image processing device, to diagnose the result of the fuel exchange operation performed by the fuel exchanger and inform the diagnosis by means of an image display. (I.S.)

  1. 77 FR 58576 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-09-21

    ... Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof; Institution of... communication devices, portable music and data processing devices, computers, and components thereof by reason... alleges that an industry in the United States exists as required by subsection (a)(2) of section 337. The...

  2. Firewood preparation devices in 1994

    International Nuclear Information System (INIS)

    Mutikainen, A.

    1994-01-01

    A review of the market situation regarding firewood preparation devices is presented. The information was collected from the answers to a mail questionnaire. The review is assumed to include all the leading manufacturers and importers. Firewood production devices were available from 26 manufacturers. The range of models amounted to over 70. These may be divided into three categories: 1. cutting devices: the most common solution being a cross-cutting circular saw. There were only a few of these on sale as it is quite easy to include a splitting device on the same frame. 2. Splitting devices: e.g. screw splitter and hydraulically powered splitter. About 20 models are available on the markets. Cross cutting and splitting devices: these are the most popular devices. A cross-cutting circular saw with screw or hydraulic splitter is the most common type. There are about 50 models available on the markets. Cross-cutting and splitting devices are often equipped with conveyor for transferring the split wood e.g. into a trailer. Chopping devices are delivered as tractor powered devices, as electric motor powered devices or as combustion engine powered devices. Some of them are equipped with a time saving feeding device enabling the next stem to be lifted into position while the previous one is being chopped. The Finnish Work Efficiency Institute's studies show that when cross-cutting and splitting of stems into pieces of 35-50 cm in length, productivity for one operator varies in between 0.8 - 3.2 m 3 /h, depending on the device and work method used. (6 refs., 1 fig., 2 tabs.)

  3. Flaw detection device

    International Nuclear Information System (INIS)

    Sasahara, Toshihiko

    1998-01-01

    The present invention provides a device for detecting welded portions of a reactor pressure vessel. Namely, the device of the present invention comprises (1) a casing to be disposed on the surface to be detected, (2) a probe driving means loaded to the casing, (3) a probe driven along the surface to be detected and (4) a pressure reduction means for keeping the hollow portion in the casing to an evacuated atmosphere. The casing comprises a flexible suction edge to be tightly in contact with the surface to be tested for maintaining the air tight state, (6) a guide wheel for moving the casing along the surface to be tested and (7) a handle for performing transferring operation. The flaw detection device thus constituted has following features. The working efficiency upon conducting detection is improved. The influence of the weight of the device on the detection is small. The device can be applied on the surface of a nonmagnetic material. The efficiency for the flaw detection can be improved. (I.S.)

  4. Fuel inspection device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi.

    1990-01-01

    The fuel inspection device of the present invention has a feature of obtaining an optimum illumination upon fuel rod interval inspection operation in a fuel pool. That is, an illumination main body used underwater is connected to a cable which is led out on a floor. A light control device is attached to the other end of the cable and an electric power cable is connected to the light control device. A light source (for example, incandescent lamp) is incorporated in the casing of the illumination main body, and a diffusion plate is disposed at the front to provide a plane light source. The light control device has a light control knob capable of remote-controlling the brightness of the light of the illumination main body. In the fuel inspection device thus constituted, halation is scarcely caused on the image screen upon inspection of fuels by a submerged type television camera to facilitate control upon inspection. Accordingly, efficiency of the fuel inspection can be improved to shorten the operation time. (I.S.)

  5. Medical Devices; Immunology and Microbiology Devices; Classification of the Device To Detect and Identify Microbial Pathogen Nucleic Acids in Cerebrospinal Fluid. Final order.

    Science.gov (United States)

    2017-10-20

    The Food and Drug Administration (FDA or we) is classifying the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid into class II (special controls). The special controls that will apply to the device type are identified in this order and will be part of the codified language for the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid’s classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  6. Smart devices are different

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Bhattacharya, Sourav

    2015-01-01

    research results. This is due to variations in training and test device hardware and their operating system characteristics among others. In this paper, we systematically investigate sensor-, device- and workload-specific heterogeneities using 36 smartphones and smartwatches, consisting of 13 different...... device models from four manufacturers. Furthermore, we conduct experiments with nine users and investigate popular feature representation and classification techniques in HAR research. Our results indicate that on-device sensor and sensor handling heterogeneities impair HAR performances significantly...

  7. Rooting an Android Device

    Science.gov (United States)

    2015-09-01

    1. Overview The purpose of this document is to demonstrate how to gain administrative privileges on an Android device. The term “rooting” is...is applicable for the Samsung Galaxy S3 as well as many other Android devices, but there are several steps involved in rooting an Android device (as...root access has been granted. 4. Conclusion This document serves as a tutorial on how to grant user administrative privilege to an Android device by

  8. Novel Magnetic Devices

    National Research Council Canada - National Science Library

    Schuller, Ivan

    2007-01-01

    ...: ballistic magnetoresistance, magnetic field proximity effect and spin drag. These three phenomena would then be exploited for the design of novel device architectures and to investigate the physical principles behind these devices...

  9. Evaluating imaging devices

    International Nuclear Information System (INIS)

    Rollo, F.D.

    1977-01-01

    The performance of any imaging device depends on two principal factors inherent to the device, namely, plane sensitivity and spatial resolution. These factors may be defined as follows: plane sensitivity is the counts per second recorded by the imaging device for each disintegration per second per square centimeter occurring within a plane sheet of radioactivity. Spatial resolution may be defined as the fidelity with which the imaging device reproduces the activity distribution of an object in the image plane. In all imaging devices, a trade-off exists between these two parameters; that is, as sensitivity improves, spatial resolution is degraded, and vice versa. Therefore, to fully evaluate an imaging system a technique should be selected that measures both parameters and reflects the trade-off between the two. In addition, the method should approximate the clinical problem, namely, the detection of a focal lesion within an activity distribution. Several methods have been described to evaluate nuclear imaging devices. The more common techniques include the use of organ phantoms, bar phantoms, line-spread functions, modulation transfer functions, contrast efficiency functions, and performance index functions. Each of these techniques is briefly described in this chapter, and their advantages and disadvantages are discussed. In addition, a phantom that can be used to simply and completely measure overall imaging system performance is described

  10. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  11. Materials for electrochemical device safety

    Science.gov (United States)

    Vissers, Daniel R.; Amine, Khalil; Thackeray, Michael M.; Kahaian, Arthur J.; Johnson, Christopher S.

    2015-04-07

    An electrochemical device includes a thermally-triggered intumescent material or a gas-triggered intumescent material. Such devices prevent or minimize short circuits in a device that could lead to thermal run-away. Such devices may include batteries or supercapacitors.

  12. Heterostructures and quantum devices

    CERN Document Server

    Einspruch, Norman G

    1994-01-01

    Heterostructure and quantum-mechanical devices promise significant improvement in the performance of electronic and optoelectronic integrated circuits (ICs). Though these devices are the subject of a vigorous research effort, the current literature is often either highly technical or narrowly focused. This book presents heterostructure and quantum devices to the nonspecialist, especially electrical engineers working with high-performance semiconductor devices. It focuses on a broad base of technical applications using semiconductor physics theory to develop the next generation of electrical en

  13. Plasma shutdown device

    International Nuclear Information System (INIS)

    Hosogane, Nobuyuki; Nakayama, Takahide.

    1985-01-01

    Purpose: To prevent concentration of plasma currents to the plasma center upon plasma shutdown in a torus type thermonuclear device by the injection of fuels to the plasma center thereby prevent plasma disruption at the plasma center. Constitution: The plasma shutdown device comprises a plasma current measuring device that measures the current distribution of plasmas confined within a vacuum vessel and outputs a control signal for cooling the plasma center when the plasma currents concentrate to the plasma center and a fuel supply device that supplies fuels to the plasma center for cooling the center. The fuels are injected in the form of pellets into the plasmas. The direction and the velocity of the injection are set such that the pellets are ionized at the center of the plasmas. (Horiuchi, T.)

  14. Photovoltaic device and method

    Science.gov (United States)

    Cleereman, Robert J; Lesniak, Michael J; Keenihan, James R; Langmaid, Joe A; Gaston, Ryan; Eurich, Gerald K; Boven, Michelle L

    2015-01-27

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  15. Magnet-assisted device-level alignment for the fabrication of membrane-sandwiched polydimethylsiloxane microfluidic devices

    International Nuclear Information System (INIS)

    Lu, J-C; Liao, W-H; Tung, Y-C

    2012-01-01

    Polydimethylsiloxane (PDMS) microfluidic device is one of the most essential techniques that advance microfluidics research in recent decades. PDMS is broadly exploited to construct microfluidic devices due to its unique and advantageous material properties. To realize more functionalities, PDMS microfluidic devices with multi-layer architectures, especially those with sandwiched membranes, have been developed for various applications. However, existing alignment methods for device fabrication are mainly based on manual observations, which are time consuming, inaccurate and inconsistent. This paper develops a magnet-assisted alignment method to enhance device-level alignment accuracy and precision without complicated fabrication processes. In the developed alignment method, magnets are embedded into PDMS layers at the corners of the device. The paired magnets are arranged in symmetric positions at each PDMS layer, and the magnetic attraction force automatically pulls the PDMS layers into the aligned position during assembly. This paper also applies the method to construct a practical microfluidic device, a tunable chaotic micromixer. The results demonstrate the successful operation of the device without failure, which suggests the accurate alignment and reliable bonding achieved by the method. Consequently, the fabrication method developed in this paper is promising to be exploited to construct various membrane-sandwiched PDMS microfluidic devices with more integrated functionalities to advance microfluidics research. (paper)

  16. Hot gas handling device and motorized vehicle comprising the device

    NARCIS (Netherlands)

    Klein Geltink, J.; Beukers, A.; Van Tooren, M.J.L.; Koussios, S.

    2012-01-01

    The invention relates to a device for handling hot exhaust gasses discharged from an internal combustion engine. The device comprises a housing (2), enclosing a space (3) for transporting the exhaust gasses. The housing (2) is provided with an entrance - opening (4) for the exhaust gasses discharged

  17. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  18. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  19. Powering biomedical devices

    CERN Document Server

    Romero, Edwar

    2013-01-01

    From exoskeletons to neural implants, biomedical devices are no less than life-changing. Compact and constant power sources are necessary to keep these devices running efficiently. Edwar Romero's Powering Biomedical Devices reviews the background, current technologies, and possible future developments of these power sources, examining not only the types of biomedical power sources available (macro, mini, MEMS, and nano), but also what they power (such as prostheses, insulin pumps, and muscular and neural stimulators), and how they work (covering batteries, biofluids, kinetic and ther

  20. Study of In-Cylinder Reactions of High Power-Density Direct Injection Diesel Engines

    National Research Council Canada - National Science Library

    Jansons, M

    2004-01-01

    Direct-injection (DI) Diesel or compression-ignition (CI) engine combustion process is investigated when new design and operational strategies are employed in order to achieve a high power-density (HPD) engine...

  1. 78 FR 24775 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2013-04-26

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers... '826 patent''). The complaint further alleges the existence of a domestic industry. The Commission's...

  2. 77 FR 38826 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2012-06-29

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof, Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers... further alleges the existence of a domestic industry. The Commission's notice of investigation named Apple...

  3. 78 FR 12785 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2013-02-25

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers... further alleges the existence of a domestic industry. The Commission's notice of investigation named Apple...

  4. Humanitarian Use Device and Humanitarian Device Exemption regulatory programs: pros and cons.

    Science.gov (United States)

    Bernad, Daniel Maxwell

    2009-03-01

    The US FDA established the Humanitarian Use Device (HUD) and Humanitarian Device Exemption (HDE) program to encourage medical device firms to address rare diseases. Despite being in existence for over a decade, there has only been one peer-reviewed publication examining this field. The objective of this report is to investigate how the HUD/HDE program differs from the standard regulatory system, discuss its potential advantages and disadvantages, and to speculate which humanitarian devices will be brought to market within the next 5 years. A total of 40 semistructured interviews with stakeholders, representing approximately half (n = 20, 49%) of the firms that have successfully obtained HDE-approved products, were performed in order to acquire the primary data for this paper. There appear to be short-term gains and long-term drains associated with launching humanitarian devices to market. This report aims to provide sponsors with information that may allow them to make better decisions during their product development of humanitarian devices and may, hopefully, also play a role in encouraging other sponsors to take the necessary steps forward in helping to find treatments for patients with rare diseases.

  5. 77 FR 14272 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-03-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus... AND MICROBIOLOGY DEVICES 0 1. The authority citation for 21 CFR part 866 continues to read as follows...

  6. 21 CFR 882.5050 - Biofeedback device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Biofeedback device. 882.5050 Section 882.5050 Food... DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5050 Biofeedback device. (a) Identification. A biofeedback device is an instrument that provides a visual or auditory signal corresponding to...

  7. 77 FR 52759 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2012-08-30

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Notice of... communication devices, portable music and data processing devices, computers and components thereof by reason of... complaint further alleges the existence of a domestic industry. The Commission's notice of investigation...

  8. Plasma facing device of thermonuclear device

    International Nuclear Information System (INIS)

    Sumita, Hideo; Ioki, Kimihiro.

    1993-01-01

    The present invention improves integrity of thermal structures of a plasma facing device. That is, in the plasma facing device, an armour block portion from a metal cooling pipe to a carbon material comprises a mixed material of the metal as the constituent material of the cooling pipe and ceramics. Then, the mixing ratio of the composition is changed continuously or stepwise to suppress peakings of remaining stresses upon production and thermal stresses upon exertion of thermal loads. Accordingly, thermal integrity of the structural materials can further be improved. In this case, a satisfactory characteristic can be obtained also by using ceramics instead of carbon for the mixed material, and the characteristic such as heat expansion coefficient is similar to that of the armour tile. (I.S.)

  9. Cybersecurity for Connected Diabetes Devices.

    Science.gov (United States)

    Klonoff, David C

    2015-04-16

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. © 2015 Diabetes Technology Society.

  10. Human Factors and Medical Devices

    International Nuclear Information System (INIS)

    Dick Sawyer

    1998-01-01

    Medical device hardware- and software-driven user interfaces should be designed to minimize the likelihood of use-related errors and their consequences. The role of design-induced errors in medical device incidents is attracting widespread attention. The U.S. Food and Drug Administration (FDA) is fully cognizant that human factors engineering is critical to the design of safe medical devices, and user interface design is receiving substantial attention by the agency. Companies are paying more attention to the impact of device design, including user instructions, upon the performance of those health professionals and lay users who operate medical devices. Concurrently, the FDA is monitoring human factors issues in its site inspections, premarket device approvals, and postmarket incident evaluations. Overall, the outlook for improved designs and safer device operation is bright

  11. Radiation emitting devices act

    International Nuclear Information System (INIS)

    1970-01-01

    This Act, entitled the Radiation Emitting Devices Act, is concerned with the sale and importation of radiation emitting devices. Laws relating to the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of these devices are listed as well as penalties for any person who is convicted of breaking these laws

  12. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  13. 76 FR 69034 - Microbiology Devices; Classification of In Vitro Diagnostic Device for Yersinia Species Detection

    Science.gov (United States)

    2011-11-07

    ... Drug Administration 21 CFR Part 866 Microbiology Devices; Classification of In Vitro Diagnostic Device... CFR Part 866 [Docket No. FDA-2011-N-0729] Microbiology Devices; Classification of In Vitro Diagnostic... of the Microbiology Devices Advisory Panel (the panel). FDA is publishing in this document the...

  14. 76 FR 28689 - Microbiology Devices; Classification of In Vitro Diagnostic Device for Bacillus Species Detection

    Science.gov (United States)

    2011-05-18

    .... FDA-2011-N-0103] Microbiology Devices; Classification of In Vitro Diagnostic Device for Bacillus... of the Microbiology Devices Advisory Panel (the Panel). In addition, the proposed rule would... in the Federal Register. 1. Transcript of the FDA Microbiology Devices Panel meeting, March 7, 2002...

  15. Organic bistable light-emitting devices

    Science.gov (United States)

    Ma, Liping; Liu, Jie; Pyo, Seungmoon; Yang, Yang

    2002-01-01

    An organic bistable device, with a unique trilayer structure consisting of organic/metal/organic sandwiched between two outmost metal electrodes, has been invented. [Y. Yang, L. P. Ma, and J. Liu, U.S. Patent Pending, U.S. 01/17206 (2001)]. When the device is biased with voltages beyond a critical value (for example 3 V), the device suddenly switches from a high-impedance state to a low-impedance state, with a difference in injection current of more than 6 orders of magnitude. When the device is switched to the low-impedance state, it remains in that state even when the power is off. (This is called "nonvolatile" phenomenon in memory devices.) The high-impedance state can be recovered by applying a reverse bias; therefore, this bistable device is ideal for memory applications. In order to increase the data read-out rate of this type of memory device, a regular polymer light-emitting diode has been integrated with the organic bistable device, such that it can be read out optically. These features make the organic bistable light-emitting device a promising candidate for several applications, such as digital memories, opto-electronic books, and recordable papers.

  16. Semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2011-03-15

    Novel articles and methods to fabricate the same resulting in flexible, large-area, triaxially textured, single-crystal or single-crystal-like, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  17. Secure-Network-Coding-Based File Sharing via Device-to-Device Communication

    OpenAIRE

    Wang, Lei; Wang, Qing

    2017-01-01

    In order to increase the efficiency and security of file sharing in the next-generation networks, this paper proposes a large scale file sharing scheme based on secure network coding via device-to-device (D2D) communication. In our scheme, when a user needs to share data with others in the same area, the source node and all the intermediate nodes need to perform secure network coding operation before forwarding the received data. This process continues until all the mobile devices in the netw...

  18. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  19. 78 FR 26786 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Microbiology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  20. 76 FR 48871 - Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-08-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Immunology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  1. Solar panel foundation device

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1983-03-29

    A transportable solar panel foundation device which has a bottom member, at least one upstanding side member, and an essentially open top. The side members are angled to permit nesting of a plurality of the foundation devices, and reinforcement pads are carried by the foundation device to support legs for one or more solar panels.

  2. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  3. After-heat removing device

    International Nuclear Information System (INIS)

    Iwashige, Kengo; Otsuka, Masaya; Yokoyama, Iwao; Yamakawa, Masanori.

    1990-01-01

    The present invention concerns an after-heat removing device for first reactors. A heat accumulation portion provided in a cooling channel of an after-heat removing device is disposed before a coil-like heat conduction pipe for cooling of the after-heat removing device. During normal reactor operation, the temperature in the heat accumulation portion is near the temperature of the high temperature plenum due to heat conduction and heat transfer from the high temperature plenum. When the reactor is shutdown and the after-heat removing device is started, coolants cooled in the air cooler start circulation. The coolants arriving at the heat accumulation portion deprive heat from the heat accumulation portion and, ion turn, increase their temperature and then reach the cooling coil. Subsequently, the heat calorie possessed in the heat accumulation portion is reduced and the after-heat removing device is started for the operation at a full power. This can reduce the thermal shocks applied to the cooling coil or structures in a reactor vessel upon starting the after-heat removing device. (I.N.)

  4. Utilization technique on variable speed device

    International Nuclear Information System (INIS)

    1989-12-01

    This reports of workshop on power technology describes using technique on variable speed device, which deals with alternating current situation and prospect of current variable speed device, technical trend and prospect of electronics, reduce expenses by variable speed device, control technique, measurement technology, high voltage variable speed device, recent trend of inverter technology, low voltage and high voltage variable speed device control device, operating variable speed device in cooling fan, FDF application and defect case of variable speed device, cooling pump application of water variable transformer, inverter application and energy effect of ventilation equipment, application of variable speed device and analysis of the result of operation and study for application of variable speed technology.

  5. Hardware device binding and mutual authentication

    Science.gov (United States)

    Hamlet, Jason R; Pierson, Lyndon G

    2014-03-04

    Detection and deterrence of device tampering and subversion by substitution may be achieved by including a cryptographic unit within a computing device for binding multiple hardware devices and mutually authenticating the devices. The cryptographic unit includes a physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a binding PUF value. The cryptographic unit uses the binding PUF value during an enrollment phase and subsequent authentication phases. During a subsequent authentication phase, the cryptographic unit uses the binding PUF values of the multiple hardware devices to generate a challenge to send to the other device, and to verify a challenge received from the other device to mutually authenticate the hardware devices.

  6. Partial Device Fingerprints

    NARCIS (Netherlands)

    Ciere, M.; Hernandez Ganan, C.; van Eeten, M.J.G.

    2017-01-01

    In computing, remote devices may be identified by means of device fingerprinting, which works by collecting a myriad of clientside attributes such as the device’s browser and operating system version, installed plugins, screen resolution, hardware artifacts, Wi-Fi settings, and anything else

  7. A randomized trial of energy-restricted high-protein versus high-carbohydrate, low-fat diet in morbid obesity.

    Science.gov (United States)

    Dalle Grave, Riccardo; Calugi, Simona; Gavasso, Ilaria; El Ghoch, Marwan; Marchesini, Giulio

    2013-09-01

    Conflicting evidence exists as to weight loss produced by diets with different carbohydrate/protein ratio. The aim was to compare the long-term effects of high-protein vs. high-carbohydrate diet (HPD, HCD), combined with cognitive behavior therapy (CBT). In a randomized trial, 88 obese participants (mean age, 46.7; mean BMI, 45.6 kg m(-2) ) were enrolled in a 3-week inpatient and 48-week outpatient treatment, with continuous CBT during the study period. All subjects consumed a restricted diet (1,200 kcal day(-1) for women, 1,500 for men; 20% energy from fat, fat). HPD derived 34% energy from proteins, 46% from carbohydrates; HCD 17% from proteins, 64% from carbohydrates. The primary outcome was 1-year percent weight loss. Secondary outcomes were attrition rates and changes in cardiovascular risk factors and psychological profile. Attrition rates were similar between groups (25.6%). In the intention-to-treat analysis, weight loss averaged 15.0% in HPD and 13.3% in HCD at 1 year, without any difference throughout the study period. Both diets produced a similar improvement in secondary outcomes. The relative carbohydrate and protein content of the diet, when combined with intensive CBT, does not significantly affect attrition rate, weight loss and psychosocial outcome in patients with severe obesity. Copyright © 2013 The Obesity Society.

  8. Vibro-fluidized bed heat pump drying of mint leaves with respect to phenolic content, antioxidant activity, and color indices

    Directory of Open Access Journals (Sweden)

    Ataei Ardestani Seyed Majid

    2015-01-01

    Full Text Available Because of high porosity and stickiness of mint leaves, they could not be fluidized well during fluidization. In this study, a vibro-fluidized bed dryer assisted heat pump system was designed and fabricated to overcome this problem. The drying experiments were carried out at temperatures of 40, 50 and 60 °C. The quality of the dehydrated samples was assessed based on color indices, antioxidant activity, and total phenolic content. Drying process primarily occurred in falling rate period. The effective coefficient of moisture transfer of the samples was increased with air temperature and varied from 4.26656×10-11 to 2.95872×10-10 m2 s-1 for heat pump drying (HPD method, and 3.71918×10-11 to 1.29196×10-10 m2 s-1 for none-heat pump drying (NHPD method. The color indices for temperatures of 40 and 50 °C were very close to each other, whereas by increasing temperature to 60 °C, a remarkable loss of green color was observed. The highest phenolic content was found in methanolic extract for HPD at 60 °C, and NHPD at 50 °C contained the lowest amount of phenolic compounds. NHPD treatments showed lower antioxidant activity compared to HPD treatments at the same temperature due to the longer drying times.

  9. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  10. High-Fidelity Piezoelectric Audio Device

    Science.gov (United States)

    Woodward, Stanley E.; Fox, Robert L.; Bryant, Robert G.

    2003-01-01

    ModalMax is a very innovative means of harnessing the vibration of a piezoelectric actuator to produce an energy efficient low-profile device with high-bandwidth high-fidelity audio response. The piezoelectric audio device outperforms many commercially available speakers made using speaker cones. The piezoelectric device weighs substantially less (4 g) than the speaker cones which use magnets (10 g). ModalMax devices have extreme fabrication simplicity. The entire audio device is fabricated by lamination. The simplicity of the design lends itself to lower cost. The piezoelectric audio device can be used without its acoustic chambers and thereby resulting in a very low thickness of 0.023 in. (0.58 mm). The piezoelectric audio device can be completely encapsulated, which makes it very attractive for use in wet environments. Encapsulation does not significantly alter the audio response. Its small size (see Figure 1) is applicable to many consumer electronic products, such as pagers, portable radios, headphones, laptop computers, computer monitors, toys, and electronic games. The audio device can also be used in automobile or aircraft sound systems.

  11. Nuclear fuel shipping inspection device

    International Nuclear Information System (INIS)

    Takahashi, Toshio; Hada, Koji.

    1988-01-01

    Purpose: To provide an nuclear fuel shipping inspection device having a high detection sensitivity and capable of obtaining highly reliable inspection results. Constitution: The present invention concerns a device for distinguishing a fuel assembly having failed fuel rods in LMFBR type reactors. Coolants in a fuel assembly to be inspected are collected by a sampling pipeway and transferred to a filter device. In the filter device, granular radioactive corrosion products (CP) in the coolants are captured, to reduce the background. The coolants, after being passed through the filter device, are transferred to an FP catching device and gamma-rays of iodine and cesium nuclides are measured in FP radiation measuring device. Subsequently, the coolants transferred to a degasing device to separate rare gas FP in the coolants from the liquid phase. In a case if rare gas fission products are detected by the radiation detector, it means that there is a failed fuel rod in the fuel assembly to be inspected. Since the CP and the soluble FP are separated and extracted for the radioactivity measurement, the reliability can be improved. (Kamimura, M.)

  12. Delay reduction in multi-hop device-to-device communication using network coding

    KAUST Repository

    Douik, Ahmed S.

    2015-08-12

    This paper considers the problem of reducing the broadcast delay of wireless networks using instantly decodable network coding (IDNC) based device-to-device (D2D) communications. In D2D-enabled networks, devices help hasten the recovery of the lost packets of devices in their transmission range by sending network coded packets. To solve the problem, the different events occurring at each device are identified so as to derive an expression for the probability distribution of the decoding delay. The joint optimization problem over the set of transmitting devices and the packet combinations of each is formulated. Due to the high complexity of finding the optimal solution, this paper focuses on cooperation without interference between the transmitting users. The optimal solution, in such interference-less scenario, is expressed using a graph theory approach by introducing the cooperation graph. Extensive simulations compare the decoding delay experienced in the Point to Multi-Point (PMP), the fully connected D2D (FC-D2D) and the more practical partially connected D2D (PC-D2D) configurations and suggest that the PC-D2D outperforms the FC-D2D in all situations and provides an enormous gain for poorly connected networks.

  13. Triboluminescent tamper-indicating device

    Science.gov (United States)

    Johnston, Roger G.; Garcia, Anthony R. E.

    2002-01-01

    A tamper-indicating device is described. The device has a transparent or translucent cylindrical body that includes triboluminescent material, and an outer opaque layer that prevents ambient light from entering. A chamber in the body holds an undeveloped piece of photographic film bearing an image. The device is assembled from two body members. One of the body members includes a recess for storing film and an optical assembly that can be adjusted to prevent light from passing through the assembly and exposing the film. To use the device with a hasp, the body members are positioned on opposite sides of a hasp, inserted through the hasp, and attached. The optical assembly is then manipulated to allow any light generated from the triboluminescent materials during a tampering activity that damages the device to reach the film and destroy the image on the film.

  14. Safety device of thermonuclear device

    International Nuclear Information System (INIS)

    Aoki, Isao; Ueda, Shuzo; Seki, Yasushi; Sakurai, Akiko; Kasahara, Fumio; Obara, Atsushi; Yamauchi, Michinori.

    1997-01-01

    The present invention provides a safety device against an event of intrusion of coolants in a vacuum vessel. Namely, a coolant supply system comprises cooling tubes for supplying coolants to main reactor structure components including a vacuum vessel. A detection means detects leakage of coolants in the vacuum vessel. A coolant supply control means controls the supply of coolants to the main reactor structural components based on the leakage detection signals of the detection means. A stagnated material discharging means discharges stagnated materials in the main reactor structural components caused by the leakage of coolants. The leakage of coolants (for example, water) in the vacuum vessel can thus be detected by the water detection device in the vacuum vessel. A control value of a coolant supply means is closed by the leakage detection signals. The supply of coolants to the main reactor structural components is restricted to suppress the leakage. The stagnated materials are discharged to a tank by way of a water draining valve. (I.S.)

  15. Diamond semiconducting devices

    International Nuclear Information System (INIS)

    Polowczyk, M.; Klugmann, E.

    1999-01-01

    Many efforts to apply the semiconducting diamond for construction of electronic elements: resistors, thermistors, photoresistors, piezoresistors, hallotrons, pn diodes, Schottky diodes, IMPATT diodes, npn transistor, MESFETs and MISFETs are reviewed. Considering the possibilities of acceptor and donor doping, electrical resistivity and thermal conductivity of diamond as well as high electric-field breakdown points, that diamond devices could be used at about 30-times higher frequency and more then 8200 times power than silicon devices. Except that, due to high heat resistant of diamond, it is concluded that diamond devices can be used in environment at high temperature, range of 600 o C. (author)

  16. A gauge device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1982-01-01

    A readily transportable device of relative light weight comprising a pair of tensioned guides for providing accurate and stable reference planes. An embodiment comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a pair of arcuate compression members. The tensioned guides provide planes of reference for measuring devices moved therealong adjacent to a component to be measured. The device is especially useful for making on-site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (author)

  17. Digital communication device

    DEFF Research Database (Denmark)

    2005-01-01

    The invention concerns a digital communication device like a hearing aid or a headset. The hearing aid or headset has a power supply, a signal processing device, means for receiving a wireless signal and a receiver or loudspeaker, which produces an audio signal based on a modulated pulsed signal...... point is provided which is in electrical contact with the metal of the metal box and whereby this third connection point is connected to the electric circuitry of the communication device at a point having a stable and well defined electrical potential. In this way the electro-and magnetic radiation...

  18. Pop-rock musicians: assessment of their satisfaction provided by hearing protectors.

    Science.gov (United States)

    Santoni, Cristiane Bolzachini; Fiorini, Ana Claudia

    2010-01-01

    Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Contemporary cohort study. A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. The prevalence of hearing loss was of 21.7%. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p= 0.044), discomfort with the sound intensity in the work place (p= 0.009) and intolerance to loud sound (p= 0.029). There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.

  19. Innovative instrumentation for detecting optical transients in the hypothesis of a new improved mirror at solar furnace of Almeria

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, D.; Bartolini, C.; Cosentino, G.; Guarnieri, A.; Piccioni, A.; Beskin, G.; La Padula, C.

    2002-07-01

    The improvement of the solar Furnace mirror as light collector, with an expected Point Spread Function (PSF) of about less than 0.1 degree centigree, could provide a sufficient image definition for astronomical observations of Optical Transients (OTs). Wide-angle large aperture optics, combined with a finely pixelated imaging camera located in the focal plane 7.50 meters away from the mirrors, could offer a field of view (FOV) of 3 degree centigree diameter (30cm length). All these requirements involve the filling of focal plane by means of light having a spatial resolution of few millimeters and a time-resolution of the imager in the range of 50-1000 frame/s. A realistic approach, with regard to such demanding resolution, could be reached exploring properties of devices alternative to Photo-Multipliers tube (PMT) such as Multi Anode Photomultiplier tubes (MAPMT), semiconductor and hybrid devices (CCD, CMOS, HPD, Amorphous silicon detector etc.). These sensors, that during the last years have had a rapid development triggered by scientific, industrial and medical requirement, used or individually or coupled with optical field de magnifier (e. g. Tapers), present an efficient photon detection and a very high spatial resolution. (Author) 12 refs.

  20. Resource management for device-to-device underlay communication

    CERN Document Server

    Song, Lingyang; Xu, Chen

    2013-01-01

    Device-to-Device (D2D) communication will become a key feature supported by next generation cellular networks, a topic of enormous importance to modern communication. Currently, D2D serves as an underlay to the cellular network as a means to increase spectral efficiency. Although D2D communication brings large benefits in terms of system capacity, it also causes interference as well as increased computation complexity to cellular networks as a result of spectrum sharing. Thus, efficient resource management must be performed to guarantee a target performance level of cellular communication.This

  1. Articulating feedstock delivery device

    Science.gov (United States)

    Jordan, Kevin

    2013-11-05

    A fully articulable feedstock delivery device that is designed to operate at pressure and temperature extremes. The device incorporates an articulating ball assembly which allows for more accurate delivery of the feedstock to a target location. The device is suitable for a variety of applications including, but not limited to, delivery of feedstock to a high-pressure reaction chamber or process zone.

  2. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  3. 22 years of photodynamic therapy in China

    Science.gov (United States)

    Li, Jun-Heng

    2005-07-01

    The development of laser medicine in China is correlated with the development of laser science in China. The first Chinese ruby laser was created in 1961. Chinese pharmacists produced the Chinese HpD in 1981 and the first case of PDT was treated using Chinese HpD and Chinese laser equipment in the same year in Beijing. Its success brought attention establishing a research group supported by the government in 1982. A systemic research on PDT was then carried out and obvious results were achieved. The step taken for PDT also accelerated the researches on other kinds of laser medicine and surgery. Since 1982, thousands of patients of malignant tumors including tumors of the lung, esophagus, cardia, stomach, rectum, bladder, other urinary genital organs, face and mouth, eyes, ENT, head and neck, breast, and skin were treated using PDT in China. HpD fluorescence was examined in some centers. Except the superficial tumor cases, PDT procedures were done through the endoscopes. Since 1990"s, imaging guided percutaneous PDT was adopted in the organs cannot be reached by the endoscopes, such as liver cancer, peripheral lung cancer and others. PDT can be used for non-malignant cases such as occlusion of blood vessels, for example, we invented the treatment of port wine stains by PDT. Regular surgical operation combined with PDT for cerebral glioma showed to be a very good combination. HpD has been approved by the Chinese Government as a photosensitizer, so it is legal to be used in PDT. There are some second generation photosensitizers under studying in China, such as Hematoporphyrin monomethyl ether (HMME) etc. Lasers used for PDT now are mostly the diode laser of 630nm for the cancers. Research studies for PDT in China may be focalized on the aspects as new photosensitizers; the dosimetry in laser irradiation; atoptosis induced by PDT; preclinical and clinical studies for PDT new indications and new technologies.

  4. Organic 'Plastic' Optoelectronic Devices

    International Nuclear Information System (INIS)

    Sariciftci, N.S.

    2006-01-01

    Recent developments on conjugated polymer based photovoltaic diodes and photoactive organic field effect transistors (photOFETs) are discussed. The photophysics of such devices is based on the photoinduced charge transfer from donor type semiconducting conjugated polymers onto acceptor type conjugated polymers or acceptor molecules such as Buckminsterfullerene, C 6 0. Potentially interesting applications include sensitization of the photoconductivity and photovoltaic phenomena as well as photoresponsive organic field effect transistors (photOFETs). Furthermore, organic polymeric/inorganic nanoparticle based 'hybrid' solar cells will be discussed. This talk gives an overview of materials' aspect, charge-transport, and device physics of organic diodes and field-effect transistors. Furthermore, due to the compatibility of carbon/hydrogen based organic semiconductors with organic biomolecules and living cells there can be a great opportunity to integrate such organic semiconductor devices (biOFETs) with the living organisms. In general the largely independent bio/lifesciences and information technology of today, can be thus bridged in an advanced cybernetic approach using organic semiconductor devices embedded in bio-lifesciences. This field of bio-organic electronic devices is proposed to be an important mission of organic semiconductor devices

  5. Medical device-related pressure ulcers

    Directory of Open Access Journals (Sweden)

    Black JM

    2016-08-01

    Full Text Available Joyce M Black,1 Peggy Kalowes2 1Adult Health and Illness Department, College of Nursing, University of Nebraska Medical Center, Omaha, NE, 2Nursing Research and Innovation, Long Beach Memorial Miller Children’s & Women’s Hospital, Long Beach, CA, USA Abstract: Pressure ulcers from medical devices are common and can cause significant morbidity in patients of all ages. These pressure ulcers appear in the shape of the device and are most often found from the use of oxygen delivery devices. A hospital program designed to reduce the number of pressure ulcers from medical devices was successful. The program involved the development of a team that focused on skin, the results were then published for the staff to track their performance, and it was found that using foam dressings helped reduce the pressure from the device. The incidence of ulcers from medical devices has remained at zero at this hospital since this program was implemented. Keywords: pressure ulcer, medical device related

  6. Control rod drive hydraulic device

    International Nuclear Information System (INIS)

    Takekawa, Toru.

    1994-01-01

    The device of the present invention can reliably prevent a possible erroneous withdrawal of control rod driving mechanism when the pressure of a coolant line is increased by isolation operation of hydraulic control units upon periodical inspection for a BWR type reactor. That is, a coolant line is connected to the downstream of a hydraulic supply device. The coolant line is connected to a hydraulic control unit. A coolant hydraulic detection device and a pressure setting device are disposed to the coolant line. A closing signal line and a returning signal line are disposed, which connect the hydraulic supply device and a flow rate control valve for the hydraulic setting device. In the device of the present invention, even if pressure of supplied coolants is elevated due to isolation of hydraulic control units, the elevation of the hydraulic pressure can be prevented. Accordingly, reliability upon periodical reactor inspection can be improved. Further, the facility is simplified and the installation to an existent facility is easy. (I.S.)

  7. Device for cutting protrusions

    Science.gov (United States)

    Bzorgi, Fariborz M [Knoxville, TN

    2011-07-05

    An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

  8. Recent progress in power electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Yasuhiko; Yatsuo, Tsutomu

    1987-02-01

    Recent progress and future trends of power semiconductor devices (especially with respect to motor speed control) were described. Conventional discrete devices such as thyristors, bipolar transistors, unipolar transistors and Bi-MOS devices were referenced to. Reference was also made to High Voltage ICs. There has been steady progress with each of these power devices in current carrying capability, voltage blocking capability and switching speed. The Bipolar-MOS integreated device and the High Voltage IC are particularly interesting because their abilities and performances are much enhanced by skillful combination with conventional discrete devices. However, no one device meets all the needs, and it will always be necessary to select the right device for a specific task. (11 figs, 35 refs)

  9. Magnetic sensor device

    NARCIS (Netherlands)

    2009-01-01

    The present invention provides a sensor device and a method for detg. the presence and/or amt. of target moieties in a sample fluid, the target moieties being labeled with magnetic or magnetizable objects. The sensor device comprises a magnetic field generating means adapted for applying a retention

  10. Firewood processing devices in Finland 2002

    International Nuclear Information System (INIS)

    Mutikainen, A.; Kaerhae, K.

    2002-01-01

    This Forestry Bulletin presents a review of the market situation for firewood processing devices in Finland during March 2002. The review is based on a questionnaire sent to device manufacturers. The firewood processing devices have traditionally been divided into three groups according to their functions: cross-cutting devices, splitting devices and cross-cutting and splitting devices. With a cross-cutting device the tree can be cross-cut only. Because it is easily possible to build the splitting function into a cross-cutting device, merely manufacturing a cross-cutting devices is rare. In all the splitting machines on the market, the splitting is carried out on a horizontally operated hydraulic cylinder pushing against a splitting blade. The types of cross-cutting blade mostly used in cross-cutting and splitting devices are circular i.e. circular saw blade, and chain saw. These devices are called firewood sawing machines. In firewood chopping machines that have a chopping blade, the wood is cross-cut using a spiral or guillotine blade. The splitting is done by a wedge blade or an axe blade. The firewood chopping machines can cross-cut and split stems up to a maximum of 20-22 cm in diameter. Circular blade firewood machines use either a cone screw or hydraulic cylinder and counter blade for splitting. They can handle wood of 20-30 cm thick in diameter. Machines using a chain saw can process stems of a maximum 30-45 cm thick in diameter. All firewood machines that work with a chain saw use a hydraulic cylinder and counter blade for splitting. According to the questionnaire responses, there were 14 (12 Finnish, one Norwegian and one Italian) manufacturers of firewood processing devices in the market. There were over 80 device models. There were only three cross-cutting devices, thirty splitting devices and forty cross-cutting splitting devices. The price range of the devices was 500-66,000 euros (including 22% VAT). According to the MTT Agrifood Research Finland

  11. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  12. Simulations indicate that scores of lionfish (Pterois volitans colonized the Atlantic Ocean

    Directory of Open Access Journals (Sweden)

    Jason D. Selwyn

    2017-12-01

    Full Text Available The invasion of the western Atlantic Ocean by the Indo-Pacific red lionfish (Pterois volitans has had devastating consequences for marine ecosystems. Estimating the number of colonizing lionfish can be useful in identifying the introduction pathway and can inform policy decisions aimed at preventing similar invasions. It is well-established that at least ten lionfish were initially introduced. However, that estimate has not faced probabilistic scrutiny and is based solely on the number of haplotypes in the maternally-inherited mitochondrial control region. To rigorously estimate the number of lionfish that were introduced, we used a forward-time, Wright-Fisher, population genetic model in concert with a demographic, life-history model to simulate the invasion across a range of source population sizes and colonizing population fecundities. Assuming a balanced sex ratio and no Allee effects, the simulations indicate that the Atlantic population was founded by 118 (54–514, 95% HPD lionfish from the Indo-Pacific, the Caribbean by 84 (22–328, 95% HPD lionfish from the Atlantic, and the Gulf of Mexico by at least 114 (no upper bound on 95% HPD lionfish from the Caribbean. Increasing the size, and therefore diversity, of the Indo-Pacific source population and fecundity of the founding population caused the number of colonists to decrease, but with rapidly diminishing returns. When the simulation was parameterized to minimize the number of colonists (high θ and relative fecundity, 96 (48–216, 95% HPD colonists were most likely. In a more realistic scenario with Allee effects (e.g., 50% reduction in fecundity plaguing the colonists, the most likely number of lionfish increased to 272 (106–950, 95% HPD. These results, in combination with other published data, support the hypothesis that lionfish were introduced to the Atlantic via the aquarium trade, rather than shipping. When building the model employed here, we made assumptions that minimize

  13. Development of a high-speed single-photon pixellated detector for visible wavelengths

    CERN Document Server

    Mac Raighne, Aaron; Mathot, Serge; McPhate, Jason; Vallerga, John; Jarron, Pierre; Brownlee, Colin; O’Shea, Val

    2009-01-01

    We present the development of a high-speed, single-photon counting, Hybrid Photo Detector (HPD). The HPD consists of a vacuum tube, containing the detector assembly, sealed with a transparent optical input window. Photons incident on the photocathode eject a photoelectron into a large electric field, which accelerates the incident electron onto a silicon detector. The silicon detector is bump bonded to a Medipix readout chip. This set-up allows for the detection and readout of low incident photon intensities at rates that are otherwise unattainable with current camera technology. Reported is the fabrication of the camera that brings together a range of sophisticated design and fabrication techniques and the expected theoretical imaging performance. Applications to cellular and molecular microscopy are also described in which single-photon-counting abilities at high frame rates are crucial

  14. Proton therapy device

    International Nuclear Information System (INIS)

    Tronc, D.

    1994-01-01

    The invention concerns a proton therapy device using a proton linear accelerator which produces a proton beam with high energies and intensities. The invention lies in actual fact that the proton beam which is produced by the linear accelerator is deflected from 270 deg in its plan by a deflecting magnetic device towards a patient support including a bed the longitudinal axis of which is parallel to the proton beam leaving the linear accelerator. The patient support and the deflecting device turn together around the proton beam axis while the bed stays in an horizontal position. The invention applies to radiotherapy. 6 refs., 5 figs

  15. 78 FR 79304 - Cardiovascular Devices; Reclassification of External Counter-Pulsating Devices for Treatment of...

    Science.gov (United States)

    2013-12-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 870 [Docket No. FDA-2013-N-0487] Cardiovascular Devices; Reclassification of External Counter- Pulsating Devices for...--CARDIOVASCULAR DEVICES 0 1. The authority citation for 21 CFR part 870 continues to read as follows: Authority...

  16. 75 FR 68200 - Medical Devices; Radiology Devices; Reclassification of Full-Field Digital Mammography System

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 892 [Docket No. FDA-2008-N-0273] Medical Devices; Radiology Devices; Reclassification of Full- Field Digital... and Drugs, 21 CFR part 892 is amended as follows: PART 892--RADIOLOGY DEVICES 0 1. The authority...

  17. Plasma devices for hydrocarbon reformation

    KAUST Repository

    Cha, Min

    2017-01-01

    Plasma devices for hydrocarbon reformation are provided. Methods of using the devices for hydrocarbon reformation are also provided. The devices can include a liquid container to receive a hydrocarbon source, and a plasma torch configured

  18. 21 CFR 866.2580 - Gas-generating device.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2580 Gas-generating device. (a) Identification. A gas-generating device is a device intended for medical purposes that produces...

  19. 77 FR 18829 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-03-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  20. 76 FR 71983 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  1. Safety rod driving device

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Kurosaki, Akira.

    1988-01-01

    Purpose: To rapidly insert safety rods for a criticality experiment device into a reactor core container to stop the criticality reaction thereby prevent reactivity accidents. Constitution: A cylinder device having a safety rod as a cylinder rod attached with a piston at one end is constituted. The piston is elevated by pressurized air and attracted and fixed by an electromagnet which is a stationary device disposed at the upper portion of the cylinder. If the current supply to the electromagnet is disconnected, the safety rod constituting the cylinder rod is fallen together with the piston to the lower portion of the cylinder. Since the cylinder rod driving device has neither electrical motor nor driving screw as in the conventional device, necessary space can be reduced and the weight is decreased. In addition, since the inside of the nuclear reactor can easily be shielded completely from the external atmosphere, leakage of radioactive materials can be prevented. (Horiuchi, T.)

  2. Compound semiconductor device modelling

    CERN Document Server

    Miles, Robert

    1993-01-01

    Compound semiconductor devices form the foundation of solid-state microwave and optoelectronic technologies used in many modern communication systems. In common with their low frequency counterparts, these devices are often represented using equivalent circuit models, but it is often necessary to resort to physical models in order to gain insight into the detailed operation of compound semiconductor devices. Many of the earliest physical models were indeed developed to understand the 'unusual' phenomena which occur at high frequencies. Such was the case with the Gunn and IMPATI diodes, which led to an increased interest in using numerical simulation methods. Contemporary devices often have feature sizes so small that they no longer operate within the familiar traditional framework, and hot electron or even quantum­ mechanical models are required. The need for accurate and efficient models suitable for computer aided design has increased with the demand for a wider range of integrated devices for operation at...

  3. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  4. Fluid circulation control device

    International Nuclear Information System (INIS)

    Benard, Henri; Henocque, Jean.

    1982-01-01

    Horizontal fluid circulation control device, of the type having a pivoting flap. This device is intended for being fitted in the pipes of hydraulic installation, particularly in a bleed and venting system of a nuclear power station shifting radioactive or contaminated liquids. The characteristic of this device is the cut-out at the top of the flap to allow the air contained in the pipes to flow freely [fr

  5. 75 FR 61507 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-10-05

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the..., FDA announced that a meeting of the General and Plastic Surgery Devices Panel of the Medical Devices...

  6. Sodium aerosol recovering device

    International Nuclear Information System (INIS)

    Fujimori, Koji; Ueda, Mitsuo; Tanaka, Kazuhisa.

    1997-01-01

    A main body of a recovering device is disposed in a sodium cooled reactor or a sodium cooled test device. Air containing sodium aerosol is sucked into the main body of the recovering device by a recycling fan and introduced to a multi-staged metal mesh filter portion. The air about against each of the metal mesh filters, and the sodium aerosol in the air is collected. The air having a reduced sodium aerosol concentration circulates passing through a recycling fan and pipelines to form a circulation air streams. Sodium aerosol deposited on each of the metal mesh filters is scraped off periodically by a scraper driving device to prevent clogging of each of the metal filters. (I.N.)

  7. 75 FR 57968 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-09-23

    ...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... committee will discuss, make recommendations, and vote on information related to the PMA for the LAP-BAND...

  8. 78 FR 21129 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-04-09

    ... radiofrequency band ranging between 13 megahertz to 27.12 megahertz and is intended for the treatment of medical...] Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices...

  9. 76 FR 55398 - Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of...

    Science.gov (United States)

    2011-09-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of Meeting AGENCY... postponing the meeting of the Immunology Devices Panel of the Medical Devices Advisory Committee scheduled...

  10. A New Tool for Assessing Mobile Device Proficiency in Older Adults: The Mobile Device Proficiency Questionnaire.

    Science.gov (United States)

    Roque, Nelson A; Boot, Walter R

    2018-02-01

    Mobile device proficiency is increasingly required to participate in society. Unfortunately, there still exists a digital divide between younger and older adults, especially with respect to mobile devices (i.e., tablet computers and smartphones). Training is an important goal to ensure that older adults can reap the benefits of these devices. However, efficient/effective training depends on the ability to gauge current proficiency levels. We developed a new scale to accurately assess the mobile device proficiency of older adults: the Mobile Device Proficiency Questionnaire (MDPQ). We present and validate the MDPQ and a short 16-question version of the MDPQ (MDPQ-16). The MDPQ, its subscales, and the MDPQ-16 were found to be highly reliable and valid measures of mobile device proficiency in a large sample. We conclude that the MDPQ and MDPQ-16 may serve as useful tools for facilitating mobile device training of older adults and measuring mobile device proficiency for research purposes.

  11. Extraglottic airway devices: technology update

    Directory of Open Access Journals (Sweden)

    Sharma B

    2017-08-01

    Full Text Available Bimla Sharma, Chand Sahai, Jayashree Sood Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, New Delhi, India Abstract: Extraglottic airway devices (EADs have revolutionized the field of airway management. The invention of the laryngeal mask airway was a game changer, and since then, there have been several innovations to improve the EADs in design, functionality, safety and construction material. These have ranged from changes in the shape of the mask, number of cuffs and material used, like rubber, polyvinylchloride and latex. Phthalates, which were added to the construction material in order to increase device flexibility, were later omitted when this chemical was found to have serious adverse reproductive outcomes. The various designs brought out by numerous companies manufacturing EADs resulted in the addition of several devices to the airway market. These airway devices were put to use, many of them with inadequate or no evidence base regarding their efficacy and safety. To reduce the possibility of compromising the safety of the patient, the Difficult Airway Society (DAS formed the Airway Device Evaluation Project Team (ADEPT to strengthen the evidence base for airway equipment and vet the new extraglottic devices. A preuse careful analysis of the design and structure may help in better understanding of the functionality of a particular device. In the meantime, the search for the ideal EAD continues. Keywords: extraglottic airway devices, laryngeal mask airway, other extraglottic airway devices, safety, technology update

  12. Biomedical devices and systems security.

    Science.gov (United States)

    Arney, David; Venkatasubramanian, Krishna K; Sokolsky, Oleg; Lee, Insup

    2011-01-01

    Medical devices have been changing in revolutionary ways in recent years. One is in their form-factor. Increasing miniaturization of medical devices has made them wearable, light-weight, and ubiquitous; they are available for continuous care and not restricted to clinical settings. Further, devices are increasingly becoming connected to external entities through both wired and wireless channels. These two developments have tremendous potential to make healthcare accessible to everyone and reduce costs. However, they also provide increased opportunity for technology savvy criminals to exploit them for fun and profit. Consequently, it is essential to consider medical device security issues. In this paper, we focused on the challenges involved in securing networked medical devices. We provide an overview of a generic networked medical device system model, a comprehensive attack and adversary model, and describe some of the challenges present in building security solutions to manage the attacks. Finally, we provide an overview of two areas of research that we believe will be crucial for making medical device system security solutions more viable in the long run: forensic data logging, and building security assurance cases.

  13. Uranium material removing and recovering device

    International Nuclear Information System (INIS)

    Takita, Shin-ichi.

    1997-01-01

    A uranium material removing and recovering device for use in removing surplus uranium heavy metal (UO 2 ) generated in a uranium handling facility comprises a uranium material removing device and a uranium material recovering device. The uranium material removing device comprises an adsorbing portion filled with a uranium adsorbent, a control portion for controlling the uranium adsorbent of the uranium adsorbing portion by a controlling agent, a uranium adsorbing device connected thereto and a jetting device for jetting the adsorbing liquid to equipments deposited with uranium. The recovering device comprises a recovering apparatus for recovering uranium materials deposited with the adsorbent liquid removed by the jetting device and a recovering tank for storing the recovered uranium materials. The device of the present invention can remove surplus uranium simply and safely, mitigate body's load upon removing and recovering operations, facilitate the processing for the exchange of the adsorbent and reduces the radioactive wastes. (T.M.)

  14. Deformable paper origami optoelectronic devices

    KAUST Repository

    He, Jr-Hau

    2017-01-19

    Deformable optoelectronic devices are provided, including photodetectors, photodiodes, and photovoltaic cells. The devices can be made on a variety of paper substrates, and can include a plurality of fold segments in the paper substrate creating a deformable pattern. Thin electrode layers and semiconductor nanowire layers can be attached to the substrate, creating the optoelectronic device. The devices can be highly deformable, e.g. capable of undergoing strains of 500% or more, bending angles of 25° or more, and/or twist angles of 270° or more. Methods of making the deformable optoelectronic devices and methods of using, e.g. as a photodetector, are also provided.

  15. Plasma devices for hydrocarbon reformation

    KAUST Repository

    Cha, Min Suk

    2017-02-16

    Plasma devices for hydrocarbon reformation are provided. Methods of using the devices for hydrocarbon reformation are also provided. The devices can include a liquid container to receive a hydrocarbon source, and a plasma torch configured to be submerged in the liquid. The plasma plume from the plasma torch can cause reformation of the hydrocarbon. The device can use a variety of plasma torches that can be arranged in a variety of positions in the liquid container. The devices can be used for the reformation of gaseous hydrocarbons and/or liquid hydrocarbons. The reformation can produce methane, lower hydrocarbons, higher hydrocarbons, hydrogen gas, water, carbon dioxide, carbon monoxide, or a combination thereof.

  16. [Innovation of characteristic medicinal cupping devices].

    Science.gov (United States)

    Li, Jianping; Zhang, Hui; Yang, Jianmei; Xu, Xinchun; Niu, Yanxia; Cai, Jun

    2015-08-01

    To compare the differences in the characteristic medicinal cupping therapy between the traditional cupping device and the innovated cupping device. Fifty patients of neck and low back pain were selected. The self-comparison was adopted. The cupping therapy was applied to the acupoints located on the left or right side with the traditional cupping device and the innovated cupping device. The cupping sites were centered at bilateral Quyuan (SI 13) and Dachangshu (BL 25). The cups were retained for 10 min. The traditional cupping device was the glass with smooth border, 100mL. The innovated cupping device was the vacuum-sucking cup. The operative time, medicinal leakage, comfort and cupping marks were observed for the two different cupping devices. The operative time with the innovated medicinal cupping device was shorter obviously compared with the traditional one at Quyuan (SI 13) and Dachangshu (BL 25, both Pcupping device was remarkably improved as compared with the traditional one at the two acupoints (both Pcupping operation (both P>0. 05). The cupping marks with the innovated medicinal cupping device were much deeper than those with the traditional one after cupping therapy. The innovated cupping device is more convenent and comfortable in operation during the characteristic medicinal cupping therapy.

  17. Methods of forming semiconductor devices and devices formed using such methods

    Science.gov (United States)

    Fox, Robert V; Rodriguez, Rene G; Pak, Joshua

    2013-05-21

    Single source precursors are subjected to carbon dioxide to form particles of material. The carbon dioxide may be in a supercritical state. Single source precursors also may be subjected to supercritical fluids other than supercritical carbon dioxide to form particles of material. The methods may be used to form nanoparticles. In some embodiments, the methods are used to form chalcopyrite materials. Devices such as, for example, semiconductor devices may be fabricated that include such particles. Methods of forming semiconductor devices include subjecting single source precursors to carbon dioxide to form particles of semiconductor material, and establishing electrical contact between the particles and an electrode.

  18. 21 CFR 872.1740 - Caries detection device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Caries detection device. 872.1740 Section 872.1740...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification. The caries detection device is a device intended to show the existence of decay in a patient's tooth...

  19. 76 FR 64223 - Cardiovascular Devices; Reclassification of External Pacemaker Pulse Generator Devices

    Science.gov (United States)

    2011-10-17

    ... Drug Administration 21 CFR Part 870 Cardiovascular Devices; Reclassification of External Pacemaker... Special Controls Guidance Document: External Pacemaker Pulse Generator; Availability; Proposed Rule and... [Docket No. FDA-2011-N-0650] Cardiovascular Devices; Reclassification of External Pacemaker Pulse...

  20. Mobile Device Encryption Systems

    OpenAIRE

    Teufl , Peter; Zefferer , Thomas; Stromberger , Christof

    2013-01-01

    Part 4: Software Security; International audience; The initially consumer oriented iOS and Android platforms, and the newly available Windows Phone 8 platform start to play an important role within business related areas. Within the business context, the devices are typically deployed via mobile device management (MDM) solutions, or within the bring-your-own-device (BYOD) context. In both scenarios, the security depends on many platform security functions, such as permission systems, manageme...

  1. Magnetic-bubble devices

    International Nuclear Information System (INIS)

    Fairholme, R.J.

    1978-01-01

    Magnetic bubbles were first described only ten years ago when research workers were discussing orthoferrites containing μm diameter bubbles. However, problems of material fabrication limit crystals to a few mm across which severely curtailed device development. Since then materials have changed and rare-earth-iron garnet films can be grown up 3 inches in diameter with bubble diameters down to sizes below 1 μm. The first commercial products have device capacities in the range 64 000 to 100 000 bits with bubble diameters between 4 and 6 μm. Chip capacities of 1 Mbit are presently under development in the laboratory, as are new techniques to use submicrometre bubbles. The operation and fabrication of a bubble device is described using the serial loop devices currently being manufactured at Plessey as models. Chip organization is one important variable which directly affects the access time. A range of access times and capacities is available which offers a wide range of market opportunities, ranging from consumer products to fixed head disc replacements. some of the application areas are described. (author)

  2. Underwater running device

    International Nuclear Information System (INIS)

    Kogure, Sumio; Matsuo, Takashiro; Yoshida, Yoji

    1996-01-01

    An underwater running device for an underwater inspection device for detecting inner surfaces of a reactor or a water vessel has an outer frame and an inner frame, and both of them are connected slidably by an air cylinder and connected rotatably by a shaft. The outer frame has four outer frame legs, and each of the outer frame legs is equipped with a sucker at the top end. The inner frame has four inner frame legs each equipped with a sucker at the top end. The outer frame legs and the inner frame legs are each connected with the outer frame and the inner frame by the air cylinder. The outer and the inner frame legs can be elevated or lowered (or extended or contracted) by the air cylinder. The sucker is connected with a jet pump-type negative pressure generator. The device can run and move by repeating attraction and releasing of the outer frame legs and the inner frame legs alternately while maintaining the posture of the inspection device stably. (I.N.)

  3. Neutron measuring device

    International Nuclear Information System (INIS)

    Hatayama, Akiyoshi; Seki, Eiji; Kita, Yoshio; Nishitani, Takeo.

    1993-01-01

    The device of the present invention concerns measurement for neutrons in a tokamak type thermonuclear device and it can measure total amount of generated neutrons accurately throughout the operation period even if an error is caused in counted values by plasma disruption. That is, the device comprises (1) a means for detecting presence or absence of occurrence of plasma disruption and the time for the initiation of the occurrence, (2) a first data processing means for processing detection signals, (3) a means for detecting neutrons generated in plasmas and (4) a second data processing means for calculating integrated values for the number of neutrons generated from the start to the completion of electric discharge when no disruption occurs and calculating integrated values for the number of generated neutrons from the start of electric discharge to the time at the initiation of occurrence of the disruption when disruption is present. In the thus constituted device, even if an error is caused by frequent occurrence of plasma disruption, total time integrated amount of neutrons generated in the plasmas can be measured accurately. (I.S.)

  4. Plant monitoring device

    International Nuclear Information System (INIS)

    Moriyama, Kunio.

    1991-01-01

    The monitoring device of the present invention is most suitable to early detection for equipment abnormality, or monitoring of state upon transient conditions such as startup and shutdown of an electric power plant, a large-scaled thermonuclear device and an accelerator plant. That is, in existent moitoring devices, acquired data are stored and the present operation states are monitored in comparison. A plant operation aquisition data reproduction section is disposed to the device. From the past operation conditions stored in the plant operation data aquisition reproducing section, the number of operation cycles that agrees with the present plant operation conditions is sought, to determine the agreed aquired data. Since these aquired data are time sequential data measured based on the standard time determined by the operation sequence, aquired data can be reproduced successively on every sample pitches. With such a constitution, aquired data under the same operation conditions as the present conditions are displayed together with the measured data. Accordingly, accurate monitoring can be conducted from the start-up to the shutdown of the plant. (I.S.)

  5. Criticality alarm device

    International Nuclear Information System (INIS)

    Kasai, Kenji.

    1994-01-01

    The device of the present invention is utilized, for example, to a reprocessing facility for storing and processing nuclear fuels and measures and controls the nuclear fuel assembly system so as not to exceed criticality. That is, a conventional criticality alarm device applies a predetermined processing to neutron fluxes generated from a nuclear fuel assembly system containing nuclear fuels and outputs an alarm. The device of the present invention comprises (1) a neutron flux supply source for increasing and decreasing neutron fluxes periodically and supplying them to nuclear fuel assemblies, (2) a detector for detecting neutron fluxes in the nuclear fuel assemblies, (3) a critical state judging section for judging the critical state of the nuclear fuel assemblies based on the periodically changing signals obtained from the detector (2) and (4) an alarm section for outputting criticality alarms depending on the result of the judgement. The device of the present invention can accurately recognize the critical state of the nuclear fuel assembly system and can forecast reaching of the nuclear fuel assembly to criticality or prompt neutron critical state. (I.S.)

  6. Impact of AlO x layer on resistive switching characteristics and device-to-device uniformity of bilayered HfO x -based resistive random access memory devices

    Science.gov (United States)

    Chuang, Kai-Chi; Chung, Hao-Tung; Chu, Chi-Yan; Luo, Jun-Dao; Li, Wei-Shuo; Li, Yi-Shao; Cheng, Huang-Chung

    2018-06-01

    An AlO x layer was deposited on HfO x , and bilayered dielectric films were found to confine the formation locations of conductive filaments (CFs) during the forming process and then improve device-to-device uniformity. In addition, the Ti interposing layer was also adopted to facilitate the formation of oxygen vacancies. As a result, the resistive random access memory (RRAM) device with TiN/Ti/AlO x (1 nm)/HfO x (6 nm)/TiN stack layers demonstrated excellent device-to-device uniformity although it achieved slightly larger resistive switching characteristics, which were forming voltage (V Forming) of 2.08 V, set voltage (V Set) of 1.96 V, and reset voltage (V Reset) of ‑1.02 V, than the device with TiN/Ti/HfO x (6 nm)/TiN stack layers. However, the device with a thicker 2-nm-thick AlO x layer showed worse uniformity than the 1-nm-thick one. It was attributed to the increased oxygen atomic percentage in the bilayered dielectric films of the 2-nm-thick one. The difference in oxygen content showed that there would be less oxygen vacancies to form CFs. Therefore, the random growth of CFs would become severe and the device-to-device uniformity would degrade.

  7. Network-Assisted Device-to-Device (D2D) Direct Proximity Discovery with Underlay Communication

    DEFF Research Database (Denmark)

    Pratas, Nuno; Popovski, Petar

    2015-01-01

    ) direct communication between proximate devices. While (ii) is treated extensively in the recent literature, (i) has received relatively little attention. In this paper we analyze a network-assisted underlay proximity discovery protocol, where a cellular device can take the role of: announcer (which......Device-to-Device communications are expected to play an important role in current and future cellular generations, by increasing the spatial reuse of spectrum resources and enabling lower latency communication links. This paradigm has two fundamental building blocks: (i) proximity discovery and (ii......, we consider the case where the announcers underlay their messages in the downlink transmissions that are directed towards the monitoring devices. We propose a power control scheme applied to the downlink transmission, which copes with the underlay transmission via additional power expenditure, while...

  8. CIRSE Vascular Closure Device Registry

    NARCIS (Netherlands)

    Reekers, Jim A.; Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2011-01-01

    Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. The CIRSE registry of closure devices

  9. Case outsourcing medical device reprocessing.

    Science.gov (United States)

    Haley, Deborah

    2004-04-01

    IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.

  10. U.S. Hourly Precipitation Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Hourly Precipitation Data (HPD) is digital data set DSI-3240, archived at the National Climatic Data Center (NCDC). The primary source of data for this file is...

  11. Compressed optimization of device architectures

    Energy Technology Data Exchange (ETDEWEB)

    Frees, Adam [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Gamble, John King [Microsoft Research, Redmond, WA (United States). Quantum Architectures and Computation Group; Ward, Daniel Robert [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Center for Computing Research; Blume-Kohout, Robin J [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Center for Computing Research; Eriksson, M. A. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Friesen, Mark [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Coppersmith, Susan N. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics

    2014-09-01

    Recent advances in nanotechnology have enabled researchers to control individual quantum mechanical objects with unprecedented accuracy, opening the door for both quantum and extreme- scale conventional computation applications. As these devices become more complex, designing for facility of control becomes a daunting and computationally infeasible task. Here, motivated by ideas from compressed sensing, we introduce a protocol for the Compressed Optimization of Device Architectures (CODA). It leads naturally to a metric for benchmarking and optimizing device designs, as well as an automatic device control protocol that reduces the operational complexity required to achieve a particular output. Because this protocol is both experimentally and computationally efficient, it is readily extensible to large systems. For this paper, we demonstrate both the bench- marking and device control protocol components of CODA through examples of realistic simulations of electrostatic quantum dot devices, which are currently being developed experimentally for quantum computation.

  12. Baking exhaustion device in thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Mitsunori.

    1987-02-02

    Purpose: To rapidly remove tritium and impurity from the vacuum region in the access port of the baking exhaustion device in a thermonuclear device. Constitution: Each of the gaps at the boundary between a fixed shielding member and a blanket module and at the boundary between the blanket and a divertor is made extremely small so as to minimize the neutron streaming from plasmas. Accordingly, in the case of evacuating the vacuum region in the access port, the gap conductance is extremely poor and the exhaustion speed is low. Then, baking pipeways for flowing high temperature fluids are embedded to the surface layer at the position facing to the vacuum region and the plasma evacuation duct and the vacuum region are connected with an evacuation duct of the access port. By flowing high temperature fluids in the pipeways and conducting evacuation, baking exhaustion can be carried out rapidly. (Kamimura, M.).

  13. Geometry and Cloaking Devices

    Science.gov (United States)

    Ochiai, T.; Nacher, J. C.

    2011-09-01

    Recently, the application of geometry and conformal mappings to artificial materials (metamaterials) has attracted the attention in various research communities. These materials, characterized by a unique man-made structure, have unusual optical properties, which materials found in nature do not exhibit. By applying the geometry and conformal mappings theory to metamaterial science, it may be possible to realize so-called "Harry Potter cloaking device". Although such a device is still in the science fiction realm, several works have shown that by using such metamaterials it may be possible to control the direction of the electromagnetic field at will. We could then make an object hidden inside of a cloaking device. Here, we will explain how to design invisibility device using differential geometry and conformal mappings.

  14. Nuclear reactor monitoring device

    International Nuclear Information System (INIS)

    Mihashi, Ishi; Honma, Hitoshi.

    1993-01-01

    The monitoring device of the present invention comprises a reactor core/reactor system data measuring and controlling device, a radioactivity concentration calculation device for activated coolants for calculating a radioactivity concentration of activated coolants in a main steam and reactor water by using an appropriate physical model, a radioactivity concentration correlation and comparison device for activated coolants for comparing correlationship with a radiation dose and an abnormality alarm device. Since radioactivity of activated primary coolants is monitored at each of positions in the reactor system and occurrence of leakage and the amount thereof from a primary circuit to a secondary circuit is monitored if the reactor has secondary circuit, integrity of the reactor system can be ensured and an abnormality can be detected rapidly. Further, radioactivity concentration of activated primary circuit coolants, represented by 16 N or 15 C, is always monitored at each of positions of PWR primary circuits. When a heat transfer pipe is ruptured in a steam generator, leakage of primary circuit coolants is detected rapidly, as well as the amount of the leakage can be informed. (N.H.)

  15. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    Science.gov (United States)

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  16. Encapsulation methods for organic electrical devices

    Science.gov (United States)

    Blum, Yigal D.; Chu, William Siu-Keung; MacQueen, David Brent; Shi, Yijian

    2013-06-18

    The disclosure provides methods and materials suitable for use as encapsulation barriers in electronic devices. In one embodiment, for example, there is provided an electroluminescent device or other electronic device encapsulated by alternating layers of a silicon-containing bonding material and a ceramic material. The encapsulation methods provide, for example, electronic devices with increased stability and shelf-life. The invention is useful, for example, in the field of microelectronic devices.

  17. Implantation damage in silicon devices

    International Nuclear Information System (INIS)

    Nicholas, K.H.

    1977-01-01

    Ion implantation, is an attractive technique for producing doped layers in silicon devices but the implantation process involves disruption of the lattice and defects are formed, which can degrade device properties. Methods of minimizing such damage are discussed and direct comparisons made between implantation and diffusion techniques in terms of defects in the final devices and the electrical performance of the devices. Defects are produced in the silicon lattice during implantation but they are annealed to form secondary defects even at room temperature. The annealing can be at a low temperature ( 0 C) when migration of defects in silicon in generally small, or at high temperature when they can grow well beyond the implanted region. The defect structures can be complicated by impurity atoms knocked into the silicon from surface layers by the implantation. Defects can also be produced within layers on top of the silicon and these can be very important in device fabrication. In addition to affecting the electrical properties of the final device, defects produced during fabrication may influence the chemical properties of the materials. The use of these properties to improve devices are discussed as well as the degradation they can cause. (author)

  18. An introduction to electrooptic devices

    CERN Document Server

    Kaminow, Ivan P

    1974-01-01

    An Introduction to Electrooptic Devices aims to present an introduction to the electrooptic effect and to summarize work on devices employing the electrooptic effect. The book provides the necessary background in classical crystal optics. The text then discusses topics including crystal symmetry, the tensor description of linear dielectric properties, propagation in anisotropic media, and passive crystal optic devices. The book also describes the phenomenological description of tensor nonlinear dielectric properties of crystals, with emphasis on the electrooptic effect; device design and appli

  19. Medical Devices; Obstetrical and Gynecological Devices; Classification of the Fetal Head Elevator. Final order.

    Science.gov (United States)

    2017-12-19

    The Food and Drug Administration (FDA or we) is classifying the fetal head elevator into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the fetal head elevator's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  20. A microfluidic device with pillars

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a microfluidic device for mixing liquid reagents, the device comprises, a chip forming at least one reaction chamber between a bottom and a top and extending between an inlet and an outlet. To enable manufacturing from less rigid materials, the device comprises pillars...

  1. 76 FR 44489 - Medical Devices; Neurological Devices; Classification of Repetitive Transcranial Magnetic...

    Science.gov (United States)

    2011-07-26

    ... is an external device that delivers transcranial repetitive pulsed magnetic fields of sufficient... premarket notification, prior to marketing the device, which contains information about the rTMS system they... significant effect on the human environment. Thus, neither an environmental assessment nor an environmental...

  2. Reactor water clean-up device

    International Nuclear Information System (INIS)

    Tanaka, Koji; Egashira, Yasuo; Shimada, Fumie; Igarashi, Noboru.

    1983-01-01

    Purpose: To save a low temperature reactor water clean-up system indispensable so far and significantly simplify the system by carrying out the reactor water clean-up solely in a high temperature reactor water clean-up system. Constitution: The reactor water clean-up device comprises a high temperature clean-up pump and a high temperature adsorption device for inorganic adsorbents. The high temperature adsorption device is filled with amphoteric ion adsorbing inorganic adsorbents, or amphoteric ion adsorbing inorganic adsorbents and anionic adsorbing inorganic adsorbents. The reactor water clean-up device introduces reactor water by the high temperature clean-up pump through a recycling system to the high temperature adsorption device for inorganic adsorbents. Since cations such as cobalt ions and anions such as chlorine ions in the reactor water are simultaneously removed in the device, a low temperature reactor water clean-up system which has been indispensable so far can be saved to realize the significant simplification for the entire system. (Seki, T.)

  3. Graphene nanoribbons for electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Geng, Zhansong; Granzner, Ralf; Kittler, Mario; Schwierz, Frank [FG Festkoerperelektronik, Institut fuer Mikro- und Nanoelektronik und Institut fuer Mikro- und Nanotechnologien MacroNano registered, Technische Universitaet Ilmenau (Germany); Haehnlein, Bernd; Auge, Manuel; Pezoldt, Joerg [FG Nanotechnologie, Institut fuer Mikro- und Nanoelektronik und Institut fuer Mikro- und Nanotechnologien MacroNano registered, Technische Universitaet Ilmenau (Germany); Lebedev, Alexander A. [National Research University of Information Technologies, Mechanics and Optics, St. Petersburg (Russian Federation); Division Solid State Electronics, Ioffe Institute, Sankt-Peterburg (Russian Federation); Davydov, Valery Y. [Division Solid State Electronics, Ioffe Institute, Sankt-Peterburg (Russian Federation)

    2017-11-15

    Graphene nanoribbons show unique properties and have attracted a lot of attention in the recent past. Intensive theoretical and experimental studies on such nanostructures at both the fundamental and application-oriented levels have been performed. The present paper discusses the suitability of graphene nanoribbons devices for nanoelectronics and focuses on three specific device types - graphene nanoribbon MOSFETs, side-gate transistors, and three terminal junctions. It is shown that, on the one hand, experimental devices of each type of the three nanoribbon-based structures have been reported, that promising performance of these devices has been demonstrated and/or predicted, and that in part they possess functionalities not attainable with conventional semiconductor devices. On the other hand, it is emphasized that - in spite of the remarkable progress achieved during the past 10 years - graphene nanoribbon devices still face a lot of problems and that their prospects for future applications remain unclear. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Value-based procurement of medical devices: Application to devices for mechanical thrombectomy in ischemic stroke.

    Science.gov (United States)

    Trippoli, Sabrina; Caccese, Erminia; Marinai, Claudio; Messori, Andrea

    2018-03-01

    In the acute ischemic stroke, endovascular devices have shown promising clinical results and are also likely to represent value for money, as several modeling studies have shown. Pharmacoeconomic evaluations in this field, however, have little impact on the procurement of these devices. The present study explored how complex pharmacoeconomic models that evaluate effectiveness and cost can be incorporated into the in-hospital procurement of thrombectomy devices. As regards clinical modeling, we extracted outcomes at three months from randomized trials conducted for four thrombectomy devices, and we projected long-term results using standard Markov modeling. In estimating QALYs, the same model was run for the four devices. As regards economic modeling, we firstly estimated for each device the net monetary benefit (NMB) per patient (threshold = $60,000 per QALY); then, we simulated a competitive tender across the four products by determining the tender-based score (on a 0-to-100 scale). Prices of individual devices were obtained from manufacturers. Extensive sensitivity testing was applied to our analyses. For the four devices (Solitaire, Trevo, Penumbra, Solumbra), QALYs were 1.86, 1.52, 1,79, 1.35, NMB was $101,824, $83,546, $101,923, $69,440, and tender-based scores were 99.70, 43.43, 100, 0, respectively. Sensitivity analysis confirmed findings from base-case. Our results indicate that, in the field of thrombectomy devices, incorporating the typical tools of cost-effectiveness into the processes of tenders and procurement is feasible. Bridging the methodology of cost-effectiveness with the every-day practice of in-hospital procurement can contribute to maximizing the health returns that are generated by in-hospital expenditures for medical devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Fragment capture device

    Science.gov (United States)

    Payne, Lloyd R.; Cole, David L.

    2010-03-30

    A fragment capture device for use in explosive containment. The device comprises an assembly of at least two rows of bars positioned to eliminate line-of-sight trajectories between the generation point of fragments and a surrounding containment vessel or asset. The device comprises an array of at least two rows of bars, wherein each row is staggered with respect to the adjacent row, and wherein a lateral dimension of each bar and a relative position of each bar in combination provides blockage of a straight-line passage of a solid fragment through the adjacent rows of bars, wherein a generation point of the solid fragment is located within a cavity at least partially enclosed by the array of bars.

  6. Bolometric Device Based on Fluxoid Quantization

    Science.gov (United States)

    Bonetti, Joseph A.; Kenyon, Matthew E.; Leduc, Henry G.; Day, Peter K.

    2010-01-01

    The temperature dependence of fluxoid quantization in a superconducting loop. The sensitivity of the device is expected to surpass that of other superconducting- based bolometric devices, such as superconducting transition-edge sensors and superconducting nanowire devices. Just as important, the proposed device has advantages in sample fabrication.

  7. Fingerprinting 802.11 Devices

    National Research Council Canada - National Science Library

    Ellch, Jonathan P

    2006-01-01

    The research presented in this thesis provides the reader with a set of algorithms and techniques that enable the user to remotely determine what chipset and device driver an 802.11 device is using...

  8. Device Applications of Nonlinear Dynamics

    CERN Document Server

    Baglio, Salvatore

    2006-01-01

    This edited book is devoted specifically to the applications of complex nonlinear dynamic phenomena to real systems and device applications. While in the past decades there has been significant progress in the theory of nonlinear phenomena under an assortment of system boundary conditions and preparations, there exist comparatively few devices that actually take this rich behavior into account. "Device Applications of Nonlinear Dynamics" applies and exploits this knowledge to make devices which operate more efficiently and cheaply, while affording the promise of much better performance. Given the current explosion of ideas in areas as diverse as molecular motors, nonlinear filtering theory, noise-enhanced propagation, stochastic resonance and networked systems, the time is right to integrate the progress of complex systems research into real devices.

  9. Electronic Payments using Mobile Communication Devices

    NARCIS (Netherlands)

    Waaij, B.D. van der; Siljee, B.I.J.; Broekhuijsen, B.J.; Ponsioen, C.; Maas, A.; Aten, R.M.; Hoepman, J.H.; Loon, J.H. van; Smit, M.

    2009-01-01

    A method of making a payment uses a first mobile communication device (1) and a second mobile communication device (2), each mobile communication device being provided with a respective near field communication unit (11, 21) and at least one of the mobile communication devices being provided with an

  10. Nanoscale MOS devices: device parameter fluctuations and low-frequency noise (Invited Paper)

    Science.gov (United States)

    Wong, Hei; Iwai, Hiroshi; Liou, J. J.

    2005-05-01

    It is well-known in conventional MOS transistors that the low-frequency noise or flicker noise is mainly contributed by the trapping-detrapping events in the gate oxide and the mobility fluctuation in the surface channel. In nanoscale MOS transistors, the number of trapping-detrapping events becomes less important because of the large direct tunneling current through the ultrathin gate dielectric which reduces the probability of trapping-detrapping and the level of leakage current fluctuation. Other noise sources become more significant in nanoscale devices. The source and drain resistance noises have greater impact on the drain current noise. Significant contribution of the parasitic bipolar transistor noise in ultra-short channel and channel mobility fluctuation to the channel noise are observed. The channel mobility fluctuation in nanoscale devices could be due to the local composition fluctuation of the gate dielectric material which gives rise to the permittivity fluctuation along the channel and results in gigantic channel potential fluctuation. On the other hand, the statistical variations of the device parameters across the wafer would cause the noise measurements less accurate which will be a challenge for the applicability of analytical flicker noise model as a process or device evaluation tool for nanoscale devices. Some measures for circumventing these difficulties are proposed.

  11. Device independence for two-party cryptography and position verification with memoryless devices

    Science.gov (United States)

    Ribeiro, Jérémy; Thinh, Le Phuc; Kaniewski, Jedrzej; Helsen, Jonas; Wehner, Stephanie

    2018-06-01

    Quantum communication has demonstrated its usefulness for quantum cryptography far beyond quantum key distribution. One domain is two-party cryptography, whose goal is to allow two parties who may not trust each other to solve joint tasks. Another interesting application is position-based cryptography whose goal is to use the geographical location of an entity as its only identifying credential. Unfortunately, security of these protocols is not possible against an all powerful adversary. However, if we impose some realistic physical constraints on the adversary, there exist protocols for which security can be proven, but these so far relied on the knowledge of the quantum operations performed during the protocols. In this work we improve the device-independent security proofs of Kaniewski and Wehner [New J. Phys. 18, 055004 (2016), 10.1088/1367-2630/18/5/055004] for two-party cryptography (with memoryless devices) and we add a security proof for device-independent position verification (also memoryless devices) under different physical constraints on the adversary. We assess the quality of the devices by observing a Bell violation, and, as for Kaniewski and Wehner [New J. Phys. 18, 055004 (2016), 10.1088/1367-2630/18/5/055004], security can be attained for any violation of the Clauser-Holt-Shimony-Horne inequality.

  12. Location tracking forensics on mobile devices

    Science.gov (United States)

    Sack, Stefan; Kröger, Knut; Creutzburg, Reiner

    2013-03-01

    The spread of navigation devices has increased significantly over the last 10 years. With the help of the current development of even smaller navigation receiver units it is to navigate with almost any current smart phone. Modern navigation systems are no longer limited to satellite navigation, but use current techniques, e.g. WLAN localization. Due to the increased use of navigation devices their relevance to forensic investigations has risen rapidly. Because navigation, for example with navigation equipment and smartphones, have become common place these days, also the amount of saved navigation data has risen rapidly. All of these developments lead to a necessary forensic analysis of these devices. However, there are very few current procedures for investigating of navigation devices. Navigation data is forensically interesting because by the position of the devices in most cases the location and the traveled path of the owner can be reconstructed. In this work practices for forensic analysis of navigation devices are developed. Different devices will be analyzed and it is attempted, by means of forensic procedures to restore the traveled path of the mobile device. For analysis of the various devices different software and hardware is used. There will be presented common procedures for securing and testing of mobile devices. Further there will be represented the specials in the investigation of each device. The different classes considered are GPS handhelds, mobile navigation devices and smartphones. It will be attempted, wherever possible, to read all data of the device. The aim is to restore complete histories of the navigation data and to forensically study and analyze these data. This is realized by the usage of current forensic software e.g. TomTology or Oxygen Forensic Suite. It is also attempted to use free software whenever possible. Further alternative methods are used (e.g. rooting) to access locked data of the unit. To limit the practical work the

  13. 75 FR 47606 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of... General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee scheduled for August...

  14. Control rod selecting and driving device

    International Nuclear Information System (INIS)

    Isobe, Hideo.

    1981-01-01

    Purpose: To simultaneously drive a predetermined number of control rods in a predetermined mode by the control of addresses for predetermined number of control rods and read or write of driving codified data to and from the memory by way of a memory controller. Constitution: The system comprises a control rod information selection device for selecting predetermined control rods from a plurality of control rods disposed in a reactor and outputting information for driving them in a predetermined mode, a control rod information output device for codifying the information outputted from the above device and outputting the addresses to the predetermined control rods and driving mode coded data, and a driving device for driving said predetermined control rods in a predetermined mode in accordance with the codified data outputted from the above device, said control rod infromation output device comprising a memory device capable of storing a predetermined number of the codified data and a memory control device for storing the predetermined number of data into the above memory device at a predetermined timing while successively outputting the thus stored predetermined number of data at a predetermined timing. (Seki, T.)

  15. Providing Device Independence to Mobile Services

    OpenAIRE

    Nylander, Stina; Bylund, Markus

    2002-01-01

    People want user interfaces to services that are functional and well suited to the device they choose for access. To provide this, services must be able to offer device specific user interfaces for the wide range of devices available today. We propose to combine the two dominant approaches to platform independence, "Write Once, Run Every-where™" and "different version for each device", to create multiple device specific user interfaces for mobile services. This gives possibilities to minimize...

  16. Streamline-based microfluidic device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Kasdan, Harvey (Inventor)

    2013-01-01

    The present invention provides a streamline-based device and a method for using the device for continuous separation of particles including cells in biological fluids. The device includes a main microchannel and an array of side microchannels disposed on a substrate. The main microchannel has a plurality of stagnation points with a predetermined geometric design, for example, each of the stagnation points has a predetermined distance from the upstream edge of each of the side microchannels. The particles are separated and collected in the side microchannels.

  17. Physics of photonic devices

    CERN Document Server

    Chuang, Shun Lien

    2009-01-01

    The most up-to-date book available on the physics of photonic devices This new edition of Physics of Photonic Devices incorporates significant advancements in the field of photonics that have occurred since publication of the first edition (Physics of Optoelectronic Devices). New topics covered include a brief history of the invention of semiconductor lasers, the Lorentz dipole method and metal plasmas, matrix optics, surface plasma waveguides, optical ring resonators, integrated electroabsorption modulator-lasers, and solar cells. It also introduces exciting new fields of research such as:

  18. Nanoelectronic device applications handbook

    CERN Document Server

    Morris, James E

    2013-01-01

    Nanoelectronic Device Applications Handbook gives a comprehensive snapshot of the state of the art in nanodevices for nanoelectronics applications. Combining breadth and depth, the book includes 68 chapters on topics that range from nano-scaled complementary metal-oxide-semiconductor (CMOS) devices through recent developments in nano capacitors and AlGaAs/GaAs devices. The contributors are world-renowned experts from academia and industry from around the globe. The handbook explores current research into potentially disruptive technologies for a post-CMOS world.These include: Nanoscale advance

  19. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  20. Mobile device security for dummies

    CERN Document Server

    Campagna, Rich; Krishnan, Ashwin

    2011-01-01

    The information you need to avoid security threats on corporate mobile devices Mobile devices have essentially replaced computers for corporate users who are on the go and there are millions of networks that have little to no security. This essential guide walks you through the steps for securing a network and building a bulletproof framework that will protect and support mobile devices in the enterprise. Featuring real-world case scenarios, this straightforward guide shares invaluable advice for protecting mobile devices from the loss of sensitive and confidential corporate informati

  1. 78 FR 16684 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  2. 77 FR 20642 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  3. 76 FR 14415 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  4. 76 FR 62419 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-10-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  5. 75 FR 49940 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  6. 78 FR 30928 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  7. 76 FR 39882 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0478] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  8. High Protein Diet and Huntington's Disease

    Science.gov (United States)

    Wu, Yih-Ru; Chen, Pei; Tsai, Fuu-Jen; Yang, Chueh-Lien; Tsao, Ya-Tzu; Chang, Wen; Hsieh, I-Shan; Chern, Yijuang; Soong, Bing-Wen

    2015-01-01

    Huntington’s disease (HD) is a neurodegenerative disorder caused by the huntingtin (HTT) gene with expanded CAG repeats. In addition to the apparent brain abnormalities, impairments also occur in peripheral tissues. We previously reported that mutant Huntingtin (mHTT) exists in the liver and causes urea cycle deficiency. A low protein diet (17%) restores urea cycle activity and ameliorates symptoms in HD model mice. It remains unknown whether the dietary protein content should be monitored closely in HD patients because the normal protein consumption is lower in humans (~15% of total calories) than in mice (~22%). We assessed whether dietary protein content affects the urea cycle in HD patients. Thirty HD patients were hospitalized and received a standard protein diet (13.7% protein) for 5 days, followed by a high protein diet (HPD, 26.3% protein) for another 5 days. Urea cycle deficiency was monitored by the blood levels of citrulline and ammonia. HD progression was determined by the Unified Huntington’s Disease Rating Scale (UHDRS). The HPD increased blood citrulline concentration from 15.19 μmol/l to 16.30 μmol/l (p = 0.0378) in HD patients but did not change blood ammonia concentration. A 2-year pilot study of 14 HD patients found no significant correlation between blood citrulline concentration and HD progression. Our results indicated a short period of the HPD did not markedly compromise urea cycle function. Blood citrulline concentration is not a reliable biomarker of HD progression. PMID:25992839

  9. High Protein Diet and Huntington's Disease.

    Directory of Open Access Journals (Sweden)

    Chiung-Mei Chen

    Full Text Available Huntington's disease (HD is a neurodegenerative disorder caused by the huntingtin (HTT gene with expanded CAG repeats. In addition to the apparent brain abnormalities, impairments also occur in peripheral tissues. We previously reported that mutant Huntingtin (mHTT exists in the liver and causes urea cycle deficiency. A low protein diet (17% restores urea cycle activity and ameliorates symptoms in HD model mice. It remains unknown whether the dietary protein content should be monitored closely in HD patients because the normal protein consumption is lower in humans (~15% of total calories than in mice (~22%. We assessed whether dietary protein content affects the urea cycle in HD patients. Thirty HD patients were hospitalized and received a standard protein diet (13.7% protein for 5 days, followed by a high protein diet (HPD, 26.3% protein for another 5 days. Urea cycle deficiency was monitored by the blood levels of citrulline and ammonia. HD progression was determined by the Unified Huntington's Disease Rating Scale (UHDRS. The HPD increased blood citrulline concentration from 15.19 μmol/l to 16.30 μmol/l (p = 0.0378 in HD patients but did not change blood ammonia concentration. A 2-year pilot study of 14 HD patients found no significant correlation between blood citrulline concentration and HD progression. Our results indicated a short period of the HPD did not markedly compromise urea cycle function. Blood citrulline concentration is not a reliable biomarker of HD progression.

  10. Devices for hearing loss

    Science.gov (United States)

    ... the sounds you want to hear. Assistive listening devices bring certain sounds directly to your ears. This can ... a small room or on a stage. Other devices can bring the sound from your TV, radio, or music ...

  11. Secure-Network-Coding-Based File Sharing via Device-to-Device Communication

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2017-01-01

    Full Text Available In order to increase the efficiency and security of file sharing in the next-generation networks, this paper proposes a large scale file sharing scheme based on secure network coding via device-to-device (D2D communication. In our scheme, when a user needs to share data with others in the same area, the source node and all the intermediate nodes need to perform secure network coding operation before forwarding the received data. This process continues until all the mobile devices in the networks successfully recover the original file. The experimental results show that secure network coding is very feasible and suitable for such file sharing. Moreover, the sharing efficiency and security outperform traditional replication-based sharing scheme.

  12. Cardiovascular RiskprofilE - IMaging and gender-specific disOrders (CREw-IMAGO): rationale and design of a multicenter cohort study

    NARCIS (Netherlands)

    Zoet, G.A.; Meun, C.; Benschop, L.; Boersma, E.; Budde, R.P.; Fauser, B.; Groot, C.J. de; Lugt, A. van der; Maas, A.H.E.M.; Moons, K.G.; Lennep, J.E. Roeters van; Roos-Hesselink, J.W.; Steegers, E.A.; Rijn, B.B. van; Laven, J.S.; Franx, A.; Velthuis, B.K.

    2017-01-01

    BACKGROUND: Reproductive disorders, such as polycystic ovary syndrome (PCOS), primary ovarian insufficiency (POI) and hypertensive pregnancy disorders (HPD) like pre-eclampsia (PE), are associated with an increased risk of cardiovascular disease (CVD). Detection of early signs of cardiovascular

  13. Cardiovascular RiskprofilE - IMaging and gender-specific disOrders (CREw-IMAGO) : Rationale and design of a multicenter cohort study

    NARCIS (Netherlands)

    Zoet, Gerbrand A.; Meun, Cindy; Benschop, Laura; Boersma, Eric; Budde, Ricardo P.J.; Fauser, Bart C.J.M.; de Groot, Christianne J. M.; van der Lugt, Aad; Maas, Angela H E M; Moons, Karl G.M.; Roeters Van Lennep, Jeanine E.; Roos-Hesselink, Jolien W; Steegers, Eric A. P.; van Rijn, Bas B.; Laven, Joop S E; Franx, Arie; Velthuis, Birgitta K.

    2017-01-01

    Background: Reproductive disorders, such as polycystic ovary syndrome (PCOS), primary ovarian insufficiency (POI) and hypertensive pregnancy disorders (HPD) like pre-eclampsia (PE), are associated with an increased risk of cardiovascular disease (CVD). Detection of early signs of cardiovascular

  14. Cardiovascular RiskprofilE - IMaging and gender-specific disOrders (CREw-IMAGO): Rationale and design of a multicenter cohort study

    NARCIS (Netherlands)

    Zoet, G.A. (Gerbrand A.); C. Meun (Cindy); Benschop, L. (Laura); H. Boersma (Eric); R.P.J. Budde (Ricardo); B.C.J.M. Fauser (Bart); C.J.M. de Groot (Christianne); A. van der Lugt (Aad); A.H.E.M. Maas (Angela H.E.M.); K.G.M. Moons (Karel); J.E. Roeters van Lennep (Jeanine); J.W. Roos-Hesselink (Jolien); E.A.P. Steegers (Eric); B.B. van Rijn (Bas); J.S.E. Laven (Joop); A. Franx (Arie); B.K. Velthuis (Birgitta)

    2017-01-01

    textabstractBackground: Reproductive disorders, such as polycystic ovary syndrome (PCOS), primary ovarian insufficiency (POI) and hypertensive pregnancy disorders (HPD) like pre-eclampsia (PE), are associated with an increased risk of cardiovascular disease (CVD). Detection of early signs of

  15. Computing and Automation Division quarterly report 30 June -28 September 1975

    International Nuclear Information System (INIS)

    Walkinshaw, W.; Lea, A.T.

    1975-10-01

    The work of the Division is reported under the following heads: 360/195 operations; workload; remote facilities; system development (HASP, graphics support, ELECTRIC); user support; applications (GEC 4080); film measuring (HPD measurement, operation, and system development). (U.K.)

  16. Device independent quantum key distribution secure against coherent attacks with memoryless measurement devices

    International Nuclear Information System (INIS)

    McKague, Matthew

    2009-01-01

    Device independent quantum key distribution (QKD) aims to provide a higher degree of security than traditional QKD schemes by reducing the number of assumptions that need to be made about the physical devices used. The previous proof of security by Pironio et al (2009 New J. Phys. 11 045021) applies only to collective attacks where the state is identical and independent and the measurement devices operate identically for each trial in the protocol. We extend this result to a more general class of attacks where the state is arbitrary and the measurement devices have no memory. We accomplish this by a reduction of arbitrary adversary strategies to qubit strategies and a proof of security for qubit strategies based on the previous proof by Pironio et al and techniques adapted from Renner.

  17. Mobile Device Usage in Higher Education

    Science.gov (United States)

    Delcker, Jan; Honal, Andrea; Ifenthaler, Dirk

    2016-01-01

    This paper focuses on mobile device usage of students in higher education. While more and more students embrace mobile devices in their daily life, institutions attempt to profit from those devices for educational purposes. It is therefore crucial for institutional development to identify students' needs and how mobile devices may facilitate these…

  18. Electrical device fabrication from nanotube formations

    Science.gov (United States)

    Nicholas, Nolan Walker; Kittrell, W. Carter; Kim, Myung Jong; Schmidt, Howard K.

    2013-03-12

    A method for forming nanotube electrical devices, arrays of nanotube electrical devices, and device structures and arrays of device structures formed by the methods. Various methods of the present invention allow creation of semiconducting and/or conducting devices from readily grown SWNT carpets rather than requiring the preparation of a patterned growth channel and takes advantage of the self-controlling nature of these carpet heights to ensure a known and controlled channel length for reliable electronic properties as compared to the prior methods.

  19. Loose part monitoring device

    International Nuclear Information System (INIS)

    Nomura, Hiroshi.

    1992-01-01

    The device of the present invention estimates a place where loose parts occur and structural components as the loose parts in a fluid flow channel of a reactor device, to provide information thereof to a plant operator. That is, the device of the present invention comprises (1) a plurality of detectors disposed to each of equipments constituting fluid channels, (2) an abnormal sound sensing device for sensing signals from the detectors, (3) an estimation section for estimating the place where the loose parts occur and the structural components thereof based on the signals sensed by the abnormal sound sensing section, (4) a memory section for storing data of the plant structure necessary for the estimation, and (5) a display section for displaying the result of the estimation. In such a device, the position where the loose parts collide against the plant structural component and the energy thereof are estimated. The dropping path of the loose parts is estimated from the estimation position. Parts to be loose parts in the path are listed up. The parts on the list is selected based on the estimated energy thereby enabling to determine the loose parts. (I.S.)

  20. Reactor container cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Koji; Kinoshita, Shoichiro

    1995-11-10

    The device of the present invention efficiently lowers pressure and temperature in a reactor container upon occurrence of a severe accident in a BWR-type reactor and can cool the inside of the container for a long period of time. That is, (1) pipelines on the side of an exhaustion tower of a filter portion in a filter bent device of the reactor container are in communication with pipelines on the side of a steam inlet of a static container cooling device by way of horizontal pipelines, (2) a back flow check valve is disposed to horizontal pipelines, (3) a steam discharge valve for a pressure vessel is disposed closer to the reactor container than the joint portion between the pipelines on the side of the steam inlet and the horizontal pipelines. Upon occurrence of a severe accident, when the pressure vessel should be ruptured and steams containing aerosol in the reactor core should be filled in the reactor container, the inlet valve of the static container cooling device is closed. Steams are flown into the filter bent device of the reactor container, where the aerosols can be removed. (I.S.).

  1. MRI-powered biomedical devices.

    Science.gov (United States)

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  2. Reactor noise monitoring device

    International Nuclear Information System (INIS)

    Yamanaka, Hiroto.

    1990-01-01

    The present invention concerns a reactor noise monitoring device by detecting abnormal sounds in background noises. Vibration sounds detected by accelerometers are applied to a loose parts detector. The detector generates high alarm if there are sudden impact sounds in the background noises and applies output signals to an accumulation device. If there is slight impact sounds in the vicinity of any of the accelerometers, the accumulation device accumulates the abnormal sounds assumed to be generated from an identical site while synchronizing the waveforms for all of the channels. Then, the device outputs signals in which the background noises are cancelled, as detection signals. Therefore, S/N ratio can be improved and the abnormal sounds contained in the background noises can be detected, to thereby improve the accuracy for estimating the position where the abnormal sounds are generated. (I.S.)

  3. Integrated Ultrasonic-Photonic Devices

    DEFF Research Database (Denmark)

    Barretto, Elaine Cristina Saraiva

    in channel waveguides and Mach-Zehnder interferometers. Numerical models are developed based on the finite element method, and applied to several scenarios, such as optimization of the geometrical parameters of waveguides, use of slow light in photonic crystal waveguides and use of Lamb waves in membranized......This thesis deals with the modeling, design, fabrication and characterization of integrated ultrasonic-photonic devices, with particular focus on the use of standard semiconductor materials such as GaAs and silicon. The devices are based on the use of guided acoustic waves to modulate the light...... investigated. Comparisons are made with the numerical and experimental results, and they validate the obtained response of the acoustic and photonic components of the device. Finally, a new design for an optical frequency shifter is proposed, posing several advantages over existing devices in terms of size...

  4. [Design of SCM inoculation device].

    Science.gov (United States)

    Qian, Mingli; Xie, Haiyuan

    2014-01-01

    The first step of bacilli culture is inoculation bacteria on culture medium. Designing a device to increase efficiency of inoculation is significative. The new device is controlled by SCM. The stepper motor can drive the culture medium rotating, accelerating, decelerating, overturn and suspending. The device is high practicability and efficient, let inoculation easy for operator.

  5. Spill-Detector-and-Shutoff Device

    Science.gov (United States)

    Jarvis, M. R.; Fulton, D. S.

    1985-01-01

    Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.

  6. Evolution of atherectomy devices.

    Science.gov (United States)

    Al Khoury, G; Chaer, R

    2011-08-01

    Percutaneous atherectomy provides an alternative approach to the endovascular treatment of peripheral atherosclerotic occlusive disease beyond angioplasty and stenting, and has the theoretical advantage of lesion debulking and minimizing barotrauma to the vessel wall. Atherectomy has evolved greatly during the last decade, with currently four FDA approved devices for the treatment of peripheral arterial disease. Several reports have focused on the initial technical success rates, and demonstrated the safety and short as well as mid-term efficacy of atherectomy devices. This article will review the evolution of current atherectomy devices and the associated literature.

  7. Fundamentals of semiconductor devices

    CERN Document Server

    Lindmayer, Joseph

    1965-01-01

    Semiconductor properties ; semiconductor junctions or diodes ; transistor fundamentals ; inhomogeneous impurity distributions, drift or graded-base transistors ; high-frequency properties of transistors ; band structure of semiconductors ; high current densities and mechanisms of carrier transport ; transistor transient response and recombination processes ; surfaces, field-effect transistors, and composite junctions ; additional semiconductor characteristics ; additional semiconductor devices and microcircuits ; more metal, insulator, and semiconductor combinations for devices ; four-pole parameters and configuration rotation ; four-poles of combined networks and devices ; equivalent circuits ; the error function and its properties ; Fermi-Dirac statistics ; useful physical constants.

  8. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1972-01-01

    Electronic Devices and Circuits, Volume 3 provides a comprehensive account on electronic devices and circuits and includes introductory network theory and physics. The physics of semiconductor devices is described, along with field effect transistors, small-signal equivalent circuits of bipolar transistors, and integrated circuits. Linear and non-linear circuits as well as logic circuits are also considered. This volume is comprised of 12 chapters and begins with an analysis of the use of Laplace transforms for analysis of filter networks, followed by a discussion on the physical properties of

  9. Compound semiconductor device physics

    CERN Document Server

    Tiwari, Sandip

    2013-01-01

    This book provides one of the most rigorous treatments of compound semiconductor device physics yet published. A complete understanding of modern devices requires a working knowledge of low-dimensional physics, the use of statistical methods, and the use of one-, two-, and three-dimensional analytical and numerical analysis techniques. With its systematic and detailed**discussion of these topics, this book is ideal for both the researcher and the student. Although the emphasis of this text is on compound semiconductor devices, many of the principles discussed will also be useful to those inter

  10. Multifunctional Energy Storage and Conversion Devices.

    Science.gov (United States)

    Huang, Yan; Zhu, Minshen; Huang, Yang; Pei, Zengxia; Li, Hongfei; Wang, Zifeng; Xue, Qi; Zhi, Chunyi

    2016-10-01

    Multifunctional energy storage and conversion devices that incorporate novel features and functions in intelligent and interactive modes, represent a radical advance in consumer products, such as wearable electronics, healthcare devices, artificial intelligence, electric vehicles, smart household, and space satellites, etc. Here, smart energy devices are defined to be energy devices that are responsive to changes in configurational integrity, voltage, mechanical deformation, light, and temperature, called self-healability, electrochromism, shape memory, photodetection, and thermal responsivity. Advisable materials, device designs, and performances are crucial for the development of energy electronics endowed with these smart functions. Integrating these smart functions in energy storage and conversion devices gives rise to great challenges from the viewpoint of both understanding the fundamental mechanisms and practical implementation. Current state-of-art examples of these smart multifunctional energy devices, pertinent to materials, fabrication strategies, and performances, are highlighted. In addition, current challenges and potential solutions from materials synthesis to device performances are discussed. Finally, some important directions in this fast developing field are considered to further expand their application. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Testing device for pipeline groups and control method for testing device

    International Nuclear Information System (INIS)

    Naito, Shinji; Kajiyama, Shigeru; Takahashi, Fuminobu; Tsuchida, Kenji; Tachibana, Yukio; Shigehiro, Katsuya; Mahara, Yoichi.

    1995-01-01

    The device of the present invention comprises a testing device main body disposed to a rail, a movable mechanism positioning from a reference point, a circumferential direction scanning mechanism, an axial direction scanning mechanism, a posture control mechanism, and a testing probe. Upon testing of pipelines, the detection device main body and auxiliary members are moved from a reference point previously set on a rail for numerical control toward pipelines to be tested in a state where the axial direction scanning mechanism and the testing probe are suspended in the axial direction. The testing is conducted by controlling the position of the testing probe in the axial direction of the pipeline by means of the axial direction scanning mechanism, and scanning the testing probe to the outer circumference of the pipeline along the circumferential track by way of the circumferential direction scanning mechanism. The device can be extremely reduced in the thickness, and can be moved with no interference with pipelines and other obstacles by remote operation even under such undesired condition as the pipelines being crowded, so that non-destructive testing can be conducted accurately. (N.H.)

  12. RF and dc desensitized electroexplosive device

    Science.gov (United States)

    Krainiak, John W.; Speaks, Paul D.; Cornett, Michael S.

    1989-07-01

    This patent application relates to electroexplosive devices (EEDs) such as detonators, blasting caps and squibs, in particular to a method and device for desensitizing EEDs to electromagnetic radiation and electrostatic charges with the added ability to desensitize the device to essentially dc currents. An insensitive electroexplosive device to electrically ignite explosive is disclosed. This device is inherently immune to radio frequency (RF) radiation, and also provides protection against dc or very low frequency RF induced by arcing. A central feature is use of zeners and capacitors to form a reactively balanced bridge circuit. When constructed in semiconductor form, as described in this application, the device is capable of incorporation in small caliber ordnance.

  13. Unconventional device concepts for polymer solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Veenstra, S.C.; Slooff, L.H.; Verhees, W.J.H.; Cobussen-Pool, E.M.; Lenzmann, F.O.; Kroon, J.M. [ECN Solar Energy, Petten (Netherlands); Sessolo, M.; Bolink, H.J. [Instituto de Ciencia Molecular, Universidad de Valencia, Valencia (Spain)

    2009-09-15

    The inclusion of metal-oxide layers in polymer solar cells enables the fabrication of a series of unconventional device architectures. These devices include: semi-transparent polymer solar cells, devices with inverted polarity, as well as devices with air stable electrodes. A proof-of-principle of these devices is presented. The anticipated benefits of these novel device structures over conventional polymer solar cells are discussed.

  14. Unconventional Quantum Computing Devices

    OpenAIRE

    Lloyd, Seth

    2000-01-01

    This paper investigates a variety of unconventional quantum computation devices, including fermionic quantum computers and computers that exploit nonlinear quantum mechanics. It is shown that unconventional quantum computing devices can in principle compute some quantities more rapidly than `conventional' quantum computers.

  15. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    Barnes, C.E.

    1977-03-01

    A summary is given of studies on radiation effects in light-emitting diodes, laser diodes, detectors, optical isolators and optical fibers. It is shown that the study of radiation damage in these devices can provide valuable information concerning the nature of the devices themselves, as well as methods of hardening these devices for applications in radiation environments

  16. Digital device for synchronous storage

    International Nuclear Information System (INIS)

    Kobzar', Yu.M.; Kovtun, V.G.; Pashechko, N.I.

    1991-01-01

    Synchronous storage digital device for IR electron-photon emission spectrometer operating with analogue-to-digital converter F4223 or monocrystal converter K572PV1 is described. The device accomplished deduction of noise-background in each storage cycle. Summation and deduction operational time equals 90 ns, device output code discharge - 20, number of storages -2 23

  17. Social-Aware Relay Selection for Cooperative Multicast Device-to-Device Communications

    Directory of Open Access Journals (Sweden)

    Francesco Chiti

    2017-12-01

    Full Text Available The increasing use of social networks such as Facebook, Twitter, and Instagram to share photos, video streaming, and music among friends has generated a huge increase in the amount of data traffic over wireless networks. This social behavior has triggered new communication paradigms such as device-to-device (D2D and relaying communication schemes, which are both considered as strong drivers for the next fifth-generation (5G cellular systems. Recently, the social-aware layer and its relationship to and influence on the physical communications layer have gained great attention as emerging focus points. We focus here on the case of relaying communications to pursue the multicast data dissemination to a group of users forming a social community through a relay node, according to the extension of the D2D mode to the case of device-to-many devices. Moreover, in our case, the source selects the device to act as the relay among different users of the multicast group by taking into account both the propagation link conditions and the relay social-trust level with the constraint of minimizing the end-to-end content delivery delay. An optimization procedure is also proposed in order to achieve the best performance. Finally, numerical results are provided to highlight the advantages of considering the impact of social level on the end-to-end delivery delay in the integrated social–physical network in comparison with the classical relay-assisted multicast communications for which the relay social-trust level is not considered.

  18. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  19. Automatic liquid nitrogen feeding device

    International Nuclear Information System (INIS)

    Gillardeau, J.; Bona, F.; Dejachy, G.

    1963-01-01

    An automatic liquid nitrogen feeding device has been developed (and used) in the framework of corrosion tests realized with constantly renewed uranium hexafluoride. The issue was to feed liquid nitrogen to a large capacity metallic trap in order to condensate uranium hexafluoride at the exit of the corrosion chambers. After having studied various available devices, a feeding device has been specifically designed to be robust, secure and autonomous, as well as ensuring a high liquid nitrogen flowrate and a highly elevated feeding frequency. The device, made of standard material, has been used during 4000 hours without any problem [fr

  20. Detecting device of atomic probe

    International Nuclear Information System (INIS)

    Nikonenkov, N.V.

    1979-01-01

    Operation of an atomic-probe recording device is discussed in detail and its flowsheet is given. The basic elements of the atomic-probe recording device intented for microanalysis of metals and alloys in an atomic level are the storage oscillograph with a raster-sweep unit, a two-channel timer using frequency meters, a digital printer, and a control unit. The digital printer records information supplied by four digital devices (two frequency meters and two digital voltmeters) in a four-digit binary-decimal code. The described device provides simultaneous recording of two ions produced per one vaporation event

  1. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices.

    Science.gov (United States)

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization.

  2. PDT for malignant tumors: a clinical analysis of 152 cases

    Science.gov (United States)

    Zhuang, Shi-Zhang; Wang, Yun-Zhen; Li, Xin; Zhang, Changjun; Wang, Jian-Zhao; Zhang, Da-Ren

    1993-03-01

    Hematoporphyrin derivative (HPD) laser photodynamic therapy (PDT) was applied for the patients of 152 cases of malignant tumors, including tumors of the lip, tongue, esophagus, urinary bladder, skin, larynx, vagina, etc. Since early 1981 good results have been obtained.

  3. Progress and Prospects in Stretchable Electroluminescent Devices

    Directory of Open Access Journals (Sweden)

    Wang Jiangxin

    2017-03-01

    Full Text Available Stretchable electroluminescent (EL devices are a new form of mechanically deformable electronics that are gaining increasing interests and believed to be one of the essential technologies for next generation lighting and display applications. Apart from the simple bending capability in flexible EL devices, the stretchable EL devices are required to withstand larger mechanical deformations and accommodate stretching strain beyond 10%. The excellent mechanical conformability in these devices enables their applications in rigorous mechanical conditions such as flexing, twisting, stretching, and folding.The stretchable EL devices can be conformably wrapped onto arbitrary curvilinear surface and respond seamlessly to the external or internal forces, leading to unprecedented applications that cannot be addressed with conventional technologies. For example, they are in demand for wide applications in biomedical-related devices or sensors and soft interactive display systems, including activating devices for photosensitive drug, imaging apparatus for internal tissues, electronic skins, interactive input and output devices, robotics, and volumetric displays. With increasingly stringent demand on the mechanical requirements, the fabrication of stretchable EL device is encountering many challenges that are difficult to resolve. In this review, recent progresses in the stretchable EL devices are covered with a focus on the approaches that are adopted to tackle materials and process challenges in stretchable EL devices and delineate the strategies in stretchable electronics. We first introduce the emission mechanisms that have been successfully demonstrated on stretchable EL devices. Limitations and advantages of the different mechanisms for stretchable EL devices are also discussed. Representative reports are reviewed based on different structural and material strategies. Unprecedented applications that have been enabled by the stretchable EL devices are

  4. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.; Buttner, Ulrich; Yi, Ying

    2016-01-01

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  5. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.

    2016-03-31

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  6. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touchscreen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may include a small gas cartridge or may be provided from an external source.

  7. Projected phase-change memory devices.

    Science.gov (United States)

    Koelmans, Wabe W; Sebastian, Abu; Jonnalagadda, Vara Prasad; Krebs, Daniel; Dellmann, Laurent; Eleftheriou, Evangelos

    2015-09-03

    Nanoscale memory devices, whose resistance depends on the history of the electric signals applied, could become critical building blocks in new computing paradigms, such as brain-inspired computing and memcomputing. However, there are key challenges to overcome, such as the high programming power required, noise and resistance drift. Here, to address these, we present the concept of a projected memory device, whose distinguishing feature is that the physical mechanism of resistance storage is decoupled from the information-retrieval process. We designed and fabricated projected memory devices based on the phase-change storage mechanism and convincingly demonstrate the concept through detailed experimentation, supported by extensive modelling and finite-element simulations. The projected memory devices exhibit remarkably low drift and excellent noise performance. We also demonstrate active control and customization of the programming characteristics of the device that reliably realize a multitude of resistance states.

  8. 21 CFR 864.6100 - Bleeding time device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...

  9. Smoothing type buffer memory device

    International Nuclear Information System (INIS)

    Podorozhnyj, D.M.; Yashin, I.V.

    1990-01-01

    The layout of the micropower 4-bit smoothing type buffer memory device allowing one to record without counting the sequence of input randomly distributed pulses in multi-channel devices with serial poll, is given. The power spent by a memory cell for one binary digit recording is not greater than 0.15 mW, the device dead time is 10 mus

  10. 47 CFR 2.801 - Radiofrequency device defined.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  11. Medical devices; neurological devices; classification of the transcranial magnetic stimulator for headache. Final order.

    Science.gov (United States)

    2014-07-08

    The Food and Drug Administration (FDA) is classifying the transcranial magnetic stimulator for headache into class II (special controls). The special controls that will apply to the device are identified in this order, and will be part of the codified language for the transcranial magnetic stimulator for headache classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  12. Analysis and simulation of semiconductor devices

    CERN Document Server

    Selberherr, Siegfried

    1984-01-01

    The invention of semiconductor devices is a fairly recent one, considering classical time scales in human life. The bipolar transistor was announced in 1947, and the MOS transistor, in a practically usable manner, was demonstrated in 1960. From these beginnings the semiconductor device field has grown rapidly. The first integrated circuits, which contained just a few devices, became commercially available in the early 1960s. Immediately thereafter an evolution has taken place so that today, less than 25 years later, the manufacture of integrated circuits with over 400.000 devices per single chip is possible. Coincident with the growth in semiconductor device development, the literature concerning semiconductor device and technology issues has literally exploded. In the last decade about 50.000 papers have been published on these subjects. The advent of so called Very-Large-Scale-Integration (VLSI) has certainly revealed the need for a better understanding of basic device behavior. The miniaturization of the s...

  13. [Medical Devices Law for pain therapists].

    Science.gov (United States)

    Regner, M; Sabatowski, R

    2016-08-01

    Medical Devices Law is a relatively new legal system, which has replaced the Medical Devices Regulations still well-known in Germany. German Medical Devices Law is based on European directives, which are, in turn, incorporated into national law by the Medical Devices Act. The Medical Devices Act is a framework law and covers a number of regulations that address specific topics within Medical Devices Law. In turn, in individual regulations, reference is made to guidelines, recommendations, etc. from other sources that provide detailed technical information on specific topics. Medical Devices Law is a very complex legal system, which needs to be permanently observed due to constant updating and adjustment. In the current article, the design and the structure of the system will be described, but special emphasis will be laid on important problem areas that need to be considered when applying and operating medical products, in this case by pain therapists in particular.

  14. Medical Devices; Neurological Devices; Classification of the External Vagal Nerve Stimulator for Headache. Final order.

    Science.gov (United States)

    2017-12-27

    The Food and Drug Administration (FDA or we) is classifying the external vagal nerve stimulator for headache into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the external vagal nerve stimulator for headache's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  15. Processes for multi-layer devices utilizing layer transfer

    Science.gov (United States)

    Nielson, Gregory N; Sanchez, Carlos Anthony; Tauke-Pedretti, Anna; Kim, Bongsang; Cederberg, Jeffrey; Okandan, Murat; Cruz-Campa, Jose Luis; Resnick, Paul J

    2015-02-03

    A method includes forming a release layer over a donor substrate. A plurality of devices made of a first semiconductor material are formed over the release layer. A first dielectric layer is formed over the plurality of devices such that all exposed surfaces of the plurality of devices are covered by the first dielectric layer. The plurality of devices are chemically attached to a receiving device made of a second semiconductor material different than the first semiconductor material, the receiving device having a receiving substrate attached to a surface of the receiving device opposite the plurality of devices. The release layer is etched to release the donor substrate from the plurality of devices. A second dielectric layer is applied over the plurality of devices and the receiving device to mechanically attach the plurality of devices to the receiving device.

  16. Are Portable Stereophotogrammetric Devices Reliable in Facial Imaging? A Validation Study of VECTRA H1 Device.

    Science.gov (United States)

    Gibelli, Daniele; Pucciarelli, Valentina; Cappella, Annalisa; Dolci, Claudia; Sforza, Chiarella

    2018-01-31

    Modern 3-dimensional (3D) image acquisition systems represent a crucial technologic development in facial anatomy because of their accuracy and precision. The recently introduced portable devices can improve facial databases by increasing the number of applications. In the present study, the VECTRA H1 portable stereophotogrammetric device was validated to verify its applicability to 3D facial analysis. Fifty volunteers underwent 4 facial scans using portable VECTRA H1 and static VECTRA M3 devices (2 for each instrument). Repeatability of linear, angular, surface area, and volume measurements was verified within the device and between devices using the Bland-Altman test and the calculation of absolute and relative technical errors of measurement (TEM and rTEM, respectively). In addition, the 2 scans obtained by the same device and the 2 scans obtained by different devices were registered and superimposed to calculate the root mean square (RMS; point-to-point) distance between the 2 surfaces. Most linear, angular, and surface area measurements had high repeatability in M3 versus M3, H1 versus H1, and M3 versus H1 comparisons (range, 82.2 to 98.7%; TEM range, 0.3 to 2.0 mm, 0.4° to 1.8°; rTEM range, 0.2 to 3.1%). In contrast, volumes and RMS distances showed evident differences in M3 versus M3 and H1 versus H1 comparisons and reached the maximum when scans from the 2 different devices were compared. The portable VECTRA H1 device proved reliable for assessing linear measurements, angles, and surface areas; conversely, the influence of involuntary facial movements on volumes and RMS distances was more important compared with the static device. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Giant magneto-resistance devices

    CERN Document Server

    Hirota, Eiichi; Inomata, Koichiro

    2002-01-01

    This book deals with the application of giant magneto-resistance (GMR) effects to electronic devices. It will appeal to engineers and graduate students in the fields of electronic devices and materials. The main subjects are magnetic sensors with high resolution and magnetic read heads with high sensitivity, required for hard-disk drives with recording densities of several gigabytes. Another important subject is novel magnetic random-access memories (MRAM) with non-volatile non-destructive and radiation-resistant characteristics. Other topics include future GMR devices based on bipolar spin transistors, spin field-effect transistors (FETs) and double-tunnel junctions.

  18. Operation training aid device

    International Nuclear Information System (INIS)

    Yoshimura, Sadanori.

    1994-01-01

    The device of the present invention evaluates the propriety of an operation which is conducted optionally by a trainee depending on the state of the plant, analyzes the cause of an operation error and aids the preparation of training policy and teaching materials based on the results of the evaluation and the analysis. Namely, an operation data collection device collects operation data for the plant operation conducted by the trainee and the state of the plant during the operation. Since an operation evaluation device evaluates the plant operation in a short period of time based on the evaluation criteria of an operation evaluation knowledge base, an operation error is never overlooked. Accordingly, uniform and highly reliable operation training at definite evaluation criteria can be obtained. In addition, an error-cause analyzing device and a training policy knowledge base analyze the cause of an error inherent to each of the trainee, and it is recorded systematically independently on every trainees. Since a training policy guide device retrieves and presents an operation error and a cause of the error, there can be prepared a training policy incorporating training with respect to the operation error that each of the trainee tends to commit. (I.S.)

  19. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  20. Microfluidic chip-capillary electrophoresis devices

    CERN Document Server

    Fung, Ying Sing; Du, Fuying; Guo, Wenpeng; Ma, Tongmei; Nie, Zhou; Sun, Hui; Wu, Ruige; Zhao, Wenfeng

    2015-01-01

    Capillary electrophoresis (CE) and microfluidic chip (MC) devices are relatively mature technologies, but this book demonstrates how they can be integrated into a single, revolutionary device that can provide on-site analysis of samples when laboratory services are unavailable. By introducing the combination of CE and MC technology, Microfluidic Chip-Capillary Electrophoresis Devices broadens the scope of chemical analysis, particularly in the biomedical, food, and environmental sciences. The book gives an overview of the development of MC and CE technology as well as technology that now allows for the fabrication of MC-CE devices. It describes the operating principles that make integration possible and illustrates some achievements already made by the application of MC-CE devices in hospitals, clinics, food safety, and environmental research. The authors envision further applications for private and public use once the proof-of-concept stage has been passed and obstacles to increased commercialization are ad...

  1. 77 FR 19534 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-04-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological Reagents; Correction AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; correction...

  2. 76 FR 21237 - Medical Devices; Obstetrical and Gynecological Devices; Classification of the Hemorrhoid...

    Science.gov (United States)

    2011-04-15

    ... type of device must submit to FDA a premarket notification, prior to marketing the device, which... directs agencies to assess all costs and benefits of available regulatory alternatives and, when... economic, environmental, public health and safety, and other advantages; distributive impacts; and equity...

  3. Fibre Optic Communication Key Devices

    CERN Document Server

    Grote, Norbert

    2012-01-01

    The book gives an in-depth description of the key devices of current and next generation fibre optic communication networks. In particular, the book covers devices such as semiconductor lasers, optical amplifiers, modulators, wavelength filters, and detectors but the relevant properties of optical fibres as well. The presentations include the physical principles underlying the various devices, the technologies used for the realization of the different devices, typical performance characteristics and limitations, and development trends towards more advanced components are also illustrated. Thus the scope of the book spans relevant principles, state-of-the-art implementations, the status of current research and expected future components.

  4. The analysis of track chamber photographs using flying spot digitizers

    CERN Multimedia

    Powell, Brian W

    1966-01-01

    A vast quantity of data pours from the experiments on particle accelerators throughout the world. For example, over 300 000 photographs per week came from the three bubble chambers operating on the CERN PS at the end of 1965. The conventional method of processing these bubble chamber photographs is for each one of them to be examined ('scanned') to see whether it records an interesting particle interaction. The interesting photographs are then passed to hand operated measuring machines to obtain precise measurements of the particle trajectories recorded on the film. Similar measurements are carried out on photographs taken in film spark chamber experiments. This article on the Flying Spot Digitizers at CERN describes one of the most fruitful attempts to speed and make more accurate the process of analysis of bubble and spark chamber photographs. There are two types of Flying Spot Digitizer at CERN — the HPD or Hough Powell Device (named after Professor Hough and the author who, together, initiated the devel...

  5. 21 CFR 892.2040 - Medical image hardcopy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  6. Plant abnormality inspection device

    International Nuclear Information System (INIS)

    Takenaka, Toshio.

    1990-01-01

    The present invention concerns a plant abnormality inspection device for conducting remote or automatic patrolling inspection in a plant and, more particularly, relates to such a device as capable of detecting abnormal odors. That is, the device comprises a moving device for moving to a predetermined position in the plant, a plurality of gas sensors for different kind of gases to be inspected mounted thereon, a comparator for comparing the concentration of a gas detected by the gas sensor with the normal gas concentration at the predetermined position and a judging means for judging the absence or presence of abnormality depending on the combination of the result of the comparison and deliverying a signal if the state is abnormal. As a result, a slight amount of gas responsible to odors released upon abnormality of the plant can be detected by a plurality of gas sensors for different kinds gases to rapidly and easily find abnormal portions in the plant. (I.S.)

  7. Authenticated sensor interface device

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, Jody Rustyn; Poland, Richard W.

    2018-05-01

    A system and method for the secure storage and transmission of data is provided. A data aggregate device can be configured to receive secure data from a data source, such as a sensor, and encrypt the secure data using a suitable encryption technique, such as a shared private key technique, a public key encryption technique, a Diffie-Hellman key exchange technique, or other suitable encryption technique. The encrypted secure data can be provided from the data aggregate device to different remote devices over a plurality of segregated or isolated data paths. Each of the isolated data paths can include an optoisolator that is configured to provide one-way transmission of the encrypted secure data from the data aggregate device over the isolated data path. External data can be received through a secure data filter which, by validating the external data, allows for key exchange and other various adjustments from an external source.

  8. Zero-Power Radio Device.

    Energy Technology Data Exchange (ETDEWEB)

    Brocato, Robert W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    This report describes an unpowered radio receiver capable of detecting and responding to weak signals transmit ted from comparatively long distances . This radio receiver offers key advantages over a short range zero - power radio receiver previously described in SAND2004 - 4610, A Zero - Power Radio Receiver . The device described here can be fabricated as an integrated circuit for use in portable wireless devices, as a wake - up circuit, or a s a stand - alone receiver operating in conjunction with identification decoders or other electroni cs. It builds on key sub - components developed at Sandia National Laboratories over many years. It uses surface acoustic wave (SAW) filter technology. It uses custom component design to enable the efficient use of small aperture antennas. This device uses a key component, the pyroelectric demodulator , covered by Sandia owned U.S. Patent 7397301, Pyroelectric Demodulating Detector [1] . This device is also described in Sandia owned U.S. Patent 97266446, Zero Power Receiver [2].

  9. Three-terminal superconducting devices

    International Nuclear Information System (INIS)

    Gallagher, W.J.

    1985-01-01

    The transistor has a number of properties that make it so useful. The authors discuss these and the additional properties a transistor would need to have for high performance applications at temperatures where superconductivity could contribute advantages to system-level performance. These properties then serve as criteria by which to evaluate three-terminal devices that have been proposed for applications at superconducting temperatures. FETs can retain their transistor properties at low temperatures, but their power consumption is too large for high-speed, high-density cryogenic applications. They discuss in detail why demonstrated superconducting devices with three terminals -Josephson effect based devices, injection controlled weak links, and stacked tunnel junction devices such as the superconducting transistor proposed by K. Gray and the quiteron -- each fail to have true transistor-like properties. They conclude that the potentially very rewarding search for a transistor compatible with superconductivity in high performance applications must be in new directions

  10. Fabrication of integrated metallic MEMS devices

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Ravnkilde, Jan Tue; Hansen, Ole

    2002-01-01

    A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators are characteri......A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators...

  11. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  12. Flexible devices: from materials, architectures to applications

    Science.gov (United States)

    Zou, Mingzhi; Ma, Yue; Yuan, Xin; Hu, Yi; Liu, Jie; Jin, Zhong

    2018-01-01

    Flexible devices, such as flexible electronic devices and flexible energy storage devices, have attracted a significant amount of attention in recent years for their potential applications in modern human lives. The development of flexible devices is moving forward rapidly, as the innovation of methods and manufacturing processes has greatly encouraged the research of flexible devices. This review focuses on advanced materials, architecture designs and abundant applications of flexible devices, and discusses the problems and challenges in current situations of flexible devices. We summarize the discovery of novel materials and the design of new architectures for improving the performance of flexible devices. Finally, we introduce the applications of flexible devices as key components in real life. Project supported by the National Key R&D Program of China (Nos. 2017YFA0208200, 2016YFB0700600, 2015CB659300), the National Natural Science Foundation of China (Nos. 21403105, 21573108), and the Fundamental Research Funds for the Central Universities (No. 020514380107).

  13. An evaluation of sharp safety blood evacuation devices.

    Science.gov (United States)

    Ford, Joanna; Phillips, Peter

    This article describes an evaluation of three sharp safety blood evacuation devices in seven Welsh NHS boards and the Welsh Blood Service. Products consisted of two phlebotomy needles possessing safety shields and one phlebotomy device with wings, tubing and a retractable needle. The device companies provided the devices and appropriate training. Participating healthcare workers used the safety device instead of the conventional device to sample blood during the evaluation period and each type of device was evaluated in random order. Participants filled in a questionnaire for each type of device and then a further questionnaire comparing the two shielded evacuation needles with each other Results showed that responses to all three products were fairly positive, although each device was not liked by everyone who used it. When the two shielded evacuation devices were compared with each other, most users preferred the device with the shield positioned directly above the needle to the device with the shield at the side. However, in laboratory tests, the preferred device produced more fluid splatter than the other shielded device on activation.

  14. Wireless device connection problems and design solutions

    Science.gov (United States)

    Song, Ji-Won; Norman, Donald; Nam, Tek-Jin; Qin, Shengfeng

    2016-09-01

    Users, especially the non-expert users, commonly experience problems when connecting multiple devices with interoperability. While studies on multiple device connections are mostly concentrated on spontaneous device association techniques with a focus on security aspects, the research on user interaction for device connection is still limited. More research into understanding people is needed for designers to devise usable techniques. This research applies the Research-through-Design method and studies the non-expert users' interactions in establishing wireless connections between devices. The "Learning from Examples" concept is adopted to develop a study focus line by learning from the expert users' interaction with devices. This focus line is then used for guiding researchers to explore the non-expert users' difficulties at each stage of the focus line. Finally, the Research-through-Design approach is used to understand the users' difficulties, gain insights to design problems and suggest usable solutions. When connecting a device, the user is required to manage not only the device's functionality but also the interaction between devices. Based on learning from failures, an important insight is found that the existing design approach to improve single-device interaction issues, such as improvements to graphical user interfaces or computer guidance, cannot help users to handle problems between multiple devices. This study finally proposes a desirable user-device interaction in which images of two devices function together with a system image to provide the user with feedback on the status of the connection, which allows them to infer any required actions.

  15. High speed serdes devices and applications

    CERN Document Server

    Stauffer, David R; Sorna, Michael A; Dramstad, Kent; Ogilvie, Clarence Rosser; Amanullah, Mohammad; Rockrohr, James Donald

    2008-01-01

    Offers an understanding of the features and functions typically found on HSS devices. This book explains how these HSS devices are used in protocol applications and the analysis which must be performed to use such HSS devices.

  16. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    International Nuclear Information System (INIS)

    Elshurafa, Amro M; El-Masry, Ezz I

    2010-01-01

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch.

  17. 76 FR 36548 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-06-22

    ... information related to the humanitarian device exemption for the Berlin Heart EXCOR Pediatric Ventricular Assist Device (VAD) sponsored by Berlin Heart, Inc. The Berlin Heart EXCOR Pediatric VAD device is a..., please contact AnnMarie Williams, Conference Management Staff, at 301-796-5966, at least 7 days in...

  18. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  19. Performance of Installed Cooking Exhaust Devices

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Delp, William W.; Apte, Michael G.; Price, Philip N.

    2011-11-01

    The performance metrics of airflow, sound, and combustion product capture efficiency (CE) were measured for a convenience sample of fifteen cooking exhaust devices, as installed in residences. Results were analyzed to quantify the impact of various device- and installation-dependent parameters on CE. Measured maximum airflows were 70% or lower than values noted on product literature for 10 of the devices. Above-the-cooktop devices with flat bottom surfaces (no capture hood) – including exhaust fan/microwave combination appliances – were found to have much lower CE at similar flow rates, compared to devices with capture hoods. For almost all exhaust devices and especially for rear-mounted downdraft exhaust and microwaves, CE was substantially higher for back compared with front burner use. Flow rate, and the extent to which the exhaust device extends over the burners that are in use, also had a large effect on CE. A flow rate of 95 liters per second (200 cubic feet per minute) was necessary, but not sufficient, to attain capture efficiency in excess of 75% for the front burners. A-weighted sound levels in kitchens exceeded 57 dB when operating at the highest fan setting for all 14 devices evaluated for sound performance.

  20. Building Evacuation with Mobile Devices

    OpenAIRE

    Merkel, Sabrina

    2014-01-01

    The rapidly growing world population and increasingly dense settlements demand ever-larger and more complex buildings from today's engineers. In comparison to this technological progress, a building's equipment for emergency evacuation has been hardly developed further. This work presents a concept for a building evacuation system based on mobile devices. Furthermore, various algorithms for route planning with mobile devices and for indoor localization of mobile devices are addressed.

  1. Scanning device for a spectrometer

    International Nuclear Information System (INIS)

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  2. Floating Oil-Spill Containment Device

    Science.gov (United States)

    Jones, Jack A.

    2012-01-01

    Previous oil containment booms have an open top that allows natural gas to escape, and have significant oil leakage due to wave action. Also, a subsea pyramid oil trap exists, but cannot move relative to moving oil plumes from deepsea oil leaks. The solution is to have large, moveable oil traps. One version floats on the sea surface and has a flexible tarp cover and a lower weighted skirt to completely entrap the floating oil and natural gas. The device must have at least three sides with boats pulling at each apex, and sonar or other system to track the slowly moving oil plume, so that the boats can properly locate the booms. The oil trap device must also have a means for removal of the oil and the natural gas. A second design version has a flexible pyramid cover that is attached by lines to ballast on the ocean floor. This is similar to fixed, metal pyramid oil capture devices in the Santa Barbara Channel off the coast of California. The ballast lines for the improved design, however, would have winches that can move the pyramid to always be located above the oil and gas plume. A third design is a combination of the first two. It uses a submerged pyramid to trap oil, but has no anchor and uses boats to locate the trap. It has ballast weights located along the bottom of the tarp and/or at the corners of the trap. The improved floating oil-spill containment device has a large floating boom and weighted skirt surrounding the oil and gas entrapment area. The device is triangular (or more than three sides) and has a flexible tarp cover with a raised gas vent area. Boats pull on the apex of the triangles to maintain tension and to allow the device to move to optimum locations to trap oil and gas. The gas is retrieved from a higher buoyant part of the tarp, and oil is retrieved from the floating oil layer contained in the device. These devices can be operated in relatively severe weather, since waves will break over the devices without causing oil leaking. Also, natural

  3. A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices

    NARCIS (Netherlands)

    Hoeben, F.P.; Hoeben, F.P.; de Mul, F.F.M.; Stokkink, J.S.D.; Stokkink, H.S.D.; Koelink, M.H.; Koelink, M.H.; Greve, Jan

    1992-01-01

    A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several

  4. Structure and application of galvanomagnetic devices

    CERN Document Server

    Weiss, H

    1969-01-01

    International Series of Monographs on Semiconductors, Volume 8: Structure and Application of Galvanomagnetic Devices focuses on the composition, reactions, transformations, and applications of galvanomagnetic devices. The book first ponders on basic physical concepts, design and fabrication of galvanomagnetic devices, and properties of galvanomagnetic devices. Discussions focus on changes in electrical properties on irradiation with high-energy particles, magnetoresistor field-plate, Hall generator, preparation of semiconductor films by vacuum deposition, structure of field-plate magnetoresist

  5. Introduction to Semiconductor Devices

    Science.gov (United States)

    Brennan, Kevin F.

    2005-03-01

    This volume offers a solid foundation for understanding the most important devices used in the hottest areas of electronic engineering today, from semiconductor fundamentals to state-of-the-art semiconductor devices in the telecommunications and computing industries. Kevin Brennan describes future approaches to computing hardware and RF power amplifiers, and explains how emerging trends and system demands of computing and telecommunications systems influence the choice, design and operation of semiconductor devices. In addition, he covers MODFETs and MOSFETs, short channel effects, and the challenges faced by continuing miniaturization. His book is both an excellent senior/graduate text and a valuable reference for practicing engineers and researchers.

  6. Wireless Communications Device Wakeup Method and System

    NARCIS (Netherlands)

    Drago, S.; Sebastiano, F.; Leenaerts, D.M.W.; Breems, L.J.

    2008-01-01

    Abstract of WO 2009044368 Disclosed are wakeable wireless communications devices, and methods for waking wireless communications devices, for use in a wireless network of such devices. The devices communicate during respectively-designated timeslots according to a communications protocol. The

  7. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  8. Design of wheel-type walking-assist device

    International Nuclear Information System (INIS)

    Jung, Seung Ho; Kim, Seung Ho; Kim, Chang Hoi; Seo, Yong Chil; Jung, Kyung Min; Lee, Sung Uk

    2006-03-01

    In this research, a outdoor wheel-type walking-assist device is developed to help an elder having a poor muscular strength at legs for walking, sitting and standing up easily at outdoors, and also for going and downing stairs. In conceptually designing, the environments of an elder's activity, the size of an elder's body and a necessary function of helping an elder are considered. This device has 4 wheels for stability. When an elder walks in incline plane with the proposed device, a rear-wing is rotated to keep the supporting device horizontal, regardless of an angle of inclination. A height-controlling device, which can control the height of the supporting device for adjusting an elder's height, is varied vertically to help an elder to sit and stand-up easily. Moreover, a outdoor wheel-type walking-assist device is conceptually designed and is made. In order to design it, the preview research is investigated firstly. On the basis of the proposed walking-assist device, the outdoor walking-assist device is designed and made. The outdoor wheel-type walking-assist device can go and down stairs automatically. This device go up and down the stair of having maximum 20cm height and an angle of 25 degrees with maximum 4 sec/stairs speed, and move at flatland with 60cm/sec speed

  9. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    KAUST Repository

    Elshurafa, Amro M.

    2010-03-22

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch. © 2010 IOP Publishing Ltd.

  10. Flexural pivot device

    International Nuclear Information System (INIS)

    Flaherty, Robert.

    1986-01-01

    A flexural pivot device or rotational actuator comprises first and sceond tubular members connected by flexural members of shape-memory-alloy. These are curved in the austenitic phase at a first temperature and after cooling to the martensitic phase are flattened. On heating one of the flexural members, it bends causing relative rotation of the tubular members. Heating of another member can produce opposite rotation. Heating is electrical or by hot gas. The device may be used in a nuclear reactor. (author)

  11. 47 CFR 15.103 - Exempted devices.

    Science.gov (United States)

    2010-10-01

    ... any transportation vehicle including motor vehicles and aircraft. (b) A digital device used... digital device utilized exclusively in an appliance, e.g., microwave oven, dishwasher, clothes dryer, air conditioner (central or window), etc. (e) Specialized medical digital devices (generally used at the direction...

  12. S-Band POSIX Device Drivers for RTEMS

    Science.gov (United States)

    Lux, James P.; Lang, Minh; Peters, Kenneth J.; Taylor, Gregory H.

    2011-01-01

    This is a set of POSIX device driver level abstractions in the RTEMS RTOS (Real-Time Executive for Multiprocessor Systems real-time operating system) to SBand radio hardware devices that have been instantiated in an FPGA (field-programmable gate array). These include A/D (analog-to-digital) sample capture, D/A (digital-to-analog) sample playback, PLL (phase-locked-loop) tuning, and PWM (pulse-width-modulation)-controlled gain. This software interfaces to Sband radio hardware in an attached Xilinx Virtex-2 FPGA. It uses plug-and-play device discovery to map memory to device IDs. Instead of interacting with hardware devices directly, using direct-memory mapped access at the application level, this driver provides an application programming interface (API) offering that easily uses standard POSIX function calls. This simplifies application programming, enables portability, and offers an additional level of protection to the hardware. There are three separate device drivers included in this package: sband_device (ADC capture and DAC playback), pll_device (RF front end PLL tuning), and pwm_device (RF front end AGC control).

  13. Memory attacks on device-independent quantum cryptography.

    Science.gov (United States)

    Barrett, Jonathan; Colbeck, Roger; Kent, Adrian

    2013-01-04

    Device-independent quantum cryptographic schemes aim to guarantee security to users based only on the output statistics of any components used, and without the need to verify their internal functionality. Since this would protect users against untrustworthy or incompetent manufacturers, sabotage, or device degradation, this idea has excited much interest, and many device-independent schemes have been proposed. Here we identify a critical weakness of device-independent protocols that rely on public communication between secure laboratories. Untrusted devices may record their inputs and outputs and reveal information about them via publicly discussed outputs during later runs. Reusing devices thus compromises the security of a protocol and risks leaking secret data. Possible defenses include securely destroying or isolating used devices. However, these are costly and often impractical. We propose other more practical partial defenses as well as a new protocol structure for device-independent quantum key distribution that aims to achieve composable security in the case of two parties using a small number of devices to repeatedly share keys with each other (and no other party).

  14. CDC field mapping device - ''ROTOTRACK''

    International Nuclear Information System (INIS)

    Yamada, R.; Hawtree, J.; Kaczar, K.; Leverence, R.; McGuire, K.; Newman-Holmes, C.; Schmidt, E.E.; Shallenberger, J.

    1985-10-01

    A field mapping device for the magnet of the Collider Detector at Fermilab (CDF) was constructed. The device was used for extensive study of the CDF magnetic field distribution. The mechanical and electrical features of the device, as well as the data acquisition system and software, are described. The mechanical system was designed so that the errors on the position and angle of the probe were +-0.75 mm and +-1 mrad, respectively

  15. X-ray spot film device

    International Nuclear Information System (INIS)

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  16. Progesterone-releasing devices for cattle estrus induction and synchronization: Device optimization to anticipate shorter treatment durations and new device developments.

    Science.gov (United States)

    de Graaff, W; Grimard, B

    2018-05-01

    Synchronization programs using progesterone-releasing intravaginal devices that allow for fixed time artificial insemination are still finding increasing application in bovine reproduction. This practice is useful for rationalizing livestock management because an increased number of cows can be inseminated in one session without the need for estrus detection. Although much of the innovation related to the design and development of intravaginal devices for use in cattle took place in the previous century, progress in understanding the physiology of the bovine estrous cycle resulted in shorter treatment durations, a trend which is still continuing. In this competitive market, with little functional differentiation between the existing devices, the shorter treatment duration prompted for optimization of the progesterone content in the device, as the cost of the drug significantly contributes to the price per unit. For CIDR ® a reduction of the progesterone content of about 30 per cent was realized. Price reduction remained an important target for further device development. Next to reduction of progesterone content, cheaper and easier to process materials like polyethylene vinyl acetate (EVA) copolymers have been explored to replace the commonly used silicone elastomers. The reengineering effort of CIDR ® demonstrated that knowledge of release kinetics and insight into gradual depletion patterns in the device is critical for optimization of drug content without compromising performance (blood levels). More recent publications related to the use of alternative polymers like EVA and polyisoprene (IP) indicated encouraging results regarding further reduction of progesterone content. The use of EVA seems most promising, because it is in principle a low-cost polymer available in many grades and this thermoplastic polymer can be processed easily by means of commonly used techniques like injection molding and extrusion. The use of thermoplastic polymers, however, requires

  17. Synaptic electronics: materials, devices and applications.

    Science.gov (United States)

    Kuzum, Duygu; Yu, Shimeng; Wong, H-S Philip

    2013-09-27

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented.

  18. Securing IoT Devices at CERN

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    CERN has more than 1000 Internet of Things (IoT) devices, which are connected to the office network. We have been doing the research to find all vulnerable IoT devices in CERN and mitigated them. We are currently working on detecting IoT devices automatically and, moreover, identifying the manufacturer, model and the running firmware version. This will help the CERN Computer Security Team to spot vulnerable devices and to show the security risks associated with them.

  19. Synaptic electronics: materials, devices and applications

    International Nuclear Information System (INIS)

    Kuzum, Duygu; Yu, Shimeng; Philip Wong, H-S

    2013-01-01

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented. (topical review)

  20. Flaw detection device for plasma facing wall in thermonuclear device

    International Nuclear Information System (INIS)

    Doi, Akira.

    1996-01-01

    The present invention concerns plasma facing walls of a thermonuclear device and provides a device for detecting a thickness of amour tiles accurately and efficiently with no manual operation. Namely, the position of the plasma facing surface of the amour tile is measured using a structure to which the amour tiles are to be disposed as a reference. Also in a case of disposing new armor tiles, the position of the plasma facing surface of the armor tiles is measured to thereby measure the wearing amount of the amour tiles based on the difference between the reference and the measured value. If a measuring means capable of measuring a plurality of amour tiles at once is used efficiency of the measurement and the detection can be enhanced. Several ten thousands of amour tiles are disposed to the plasma facing wall in a large scaled thermonuclear device, and a plenty of time was required for the detection. However, the present invention can improve the accuracy for the measurement and detection and provide time and labors-saving. (I.S.)

  1. Optoelectronic Devices Advanced Simulation and Analysis

    CERN Document Server

    Piprek, Joachim

    2005-01-01

    Optoelectronic devices transform electrical signals into optical signals and vice versa by utilizing the sophisticated interaction of electrons and light within micro- and nano-scale semiconductor structures. Advanced software tools for design and analysis of such devices have been developed in recent years. However, the large variety of materials, devices, physical mechanisms, and modeling approaches often makes it difficult to select appropriate theoretical models or software packages. This book presents a review of devices and advanced simulation approaches written by leading researchers and software developers. It is intended for scientists and device engineers in optoelectronics, who are interested in using advanced software tools. Each chapter includes the theoretical background as well as practical simulation results that help to better understand internal device physics. The software packages used in the book are available to the public, on a commercial or noncommercial basis, so that the interested r...

  2. Microfabricated fuel heating value monitoring device

    Science.gov (United States)

    Robinson, Alex L [Albuquerque, NM; Manginell, Ronald P [Albuquerque, NM; Moorman, Matthew W [Albuquerque, NM

    2010-05-04

    A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

  3. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  4. Nova Southeastern University Calendars

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  5. Using the Nova Southeastern University Web Site

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  6. Nova Southeastern University (NSU) Guy Harvey Oceanographic Center

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  7. NSU Undergraduate Student Tuition and Fees

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  8. NSU Undergraduate Academic Advising Center

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  9. Privacy Statement for Nova Southeastern University

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  10. Undergraduate Events | Nova Southeastern University

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  11. NSU Emergency Advisory Information

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  12. Alumni Association | Nova Southeastern University

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  13. Student Financial Assistance | Nova Southeastern University

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  14. Employment & Careers | Nova Southeastern Universtiy

    Science.gov (United States)

    College of Psychology Dr. Kiran C. Patel College of Allopathic Medicine Dr. Kiran C. Patel College of , dentistry, law, and psychology. Certificate Receive a graduate level certificate to enhance your skills Institute Core Services & Equipment HPD Research Undergraduate Research Community Community Outreach

  15. Digital Device Architecture and the Safe Use of Flash Devices in Munitions

    Science.gov (United States)

    Katz, Richard B.; Flowers, David; Bergevin, Keith

    2017-01-01

    Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Digital devices of interest to designers include flash-based microcontrollers and field programmable gate arrays (FPGAs). Almost a decade ago, a study was undertaken to determine if flash-based microcontrollers could be safely used in fuzes and, if so, how should such devices be applied. The results were documented in the Technical Manual for the Use of Logic Devices in Safety Features. This paper will first review the Technical Manual and discuss the rationale behind the suggested architectures for microcontrollers and a brief review of the concern about data retention in flash cells. An architectural feature in the microcontroller under study will be discussed and its use will show how to screen for weak or failed cells during manufacture, storage, or immediately prior to use. As was done for microcontrollers a decade ago, architectures for a flash-based FPGA will be discussed, showing how it can be safely used in fuzes. Additionally, architectures for using non-volatile (including flash-based) storage will be discussed for SRAM-based FPGAs.

  16. Medical device software: defining key terms.

    Science.gov (United States)

    Pashkov, Vitalii; Gutorova, Nataliya; Harkusha, Andrii

    one of the areas of significant growth in medical devices has been the role of software - as an integral component of a medical device, as a standalone device and more recently as applications on mobile devices. The risk related to a malfunction of the standalone software used within healthcare is in itself not a criterion for its qualification or not as a medical device. It is therefore, necessary to clarify some criteria for the qualification of stand-alone software as medical devices Materials and methods: Ukrainian, European Union, United States of America legislation, Guidelines developed by European Commission and Food and Drug Administration's, recommendations represented by international voluntary group and scientific works. This article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. the legal regulation of software which is used for medical purpose in Ukraine limited to one definition. In European Union and United States of America were developed and applying special guidelines that help developers, manufactures and end users to difference software on types standing on medical purpose criteria. Software becomes more and more incorporated into medical devices. Developers and manufacturers may not have initially appreciated potential risks to patients and users such situation could have dangerous results for patients or users. It is necessary to develop and adopt the legislation that will intend to define the criteria for the qualification of medical device software and the application of the classification criteria to such software, provide some illustrative examples and step by step recommendations to qualify software as medical device.

  17. Nanostructured transparent conducting oxide electrochromic device

    Science.gov (United States)

    Milliron, Delia; Tangirala, Ravisubhash; Llordes, Anna; Buonsanti, Raffaella; Garcia, Guillermo

    2016-05-17

    The embodiments described herein provide an electrochromic device. In an exemplary embodiment, the electrochromic device includes (1) a substrate and (2) a film supported by the substrate, where the film includes transparent conducting oxide (TCO) nanostructures. In a further embodiment, the electrochromic device further includes (a) an electrolyte, where the nanostructures are embedded in the electrolyte, resulting in an electrolyte, nanostructure mixture positioned above the substrate and (b) a counter electrode positioned above the mixture. In a further embodiment, the electrochromic device further includes a conductive coating deposited on the substrate between the substrate and the mixture. In a further embodiment, the electrochromic device further includes a second substrate positioned above the mixture.

  18. Steam cleaning device

    International Nuclear Information System (INIS)

    Karaki, Mikio; Muraoka, Shoichi.

    1985-01-01

    Purpose: To clean complicated and long objects to be cleaned having a structure like that of nuclear reactor fuel assembly. Constitution: Steams are blown from the bottom of a fuel assembly and soon condensated initially at the bottom of a vertical water tank due to water filled therein. Then, since water in the tank is warmed nearly to the saturation temperature, purified water is supplied from a injection device below to the injection device above the water tank on every device. In this way, since purified water is sprayed successively from below to above and steams are condensated in each of the places, the entire fuel assembly elongated in the vertical direction can be cleaned completely. Water in the reservoir goes upward like the steam flow and is drained together with the eliminated contaminations through an overflow pipe. After the cleaning has been completed, a main steam valve is closed and the drain valve is opened to drain water. (Kawakami, Y.)

  19. Photoelectric transfer device

    Energy Technology Data Exchange (ETDEWEB)

    Shinomiya, Takuji; Murao, Fumihide

    1987-12-07

    Concerning the conventional photoelectric transfer device, a short-circuit current of photodiodes is switched over with MOS transistors. However, since the backgate voltage of the MOS transistor which is to be used as the switching element, is provided by the source voltage, the leakage current between the backgate and the source/drain/ channel is great and due to this leakage current, errors occur in the photoelectric transfer power output. Especially, when the leakage current of the photodiodes is small, the error becomes large. In order to solve the above problem, this invention aims at offering a photoelectric transfer device which can provide the high precision photoelectric transfer even the short-circuit current generated in the photodiodes is small and proposes a photoelectric transfer device in which the backgate voltage of the MOS transistor switching over the short-circuit current of the photodiodes is made equal to the electric potential of the mutually connected anodes (or cathodes) of the photodiodes. (3 figs)

  20. Assistive Devices for Students with Disabilities.

    Science.gov (United States)

    Wisniewski, Lech; Sedlak, Robert

    1992-01-01

    Describes a variety of devices that can assist students with disabilities. Highlights recently developed devices for students with specific learning disabilities, and with vision, hearing, health, physical, and speech and language impairments. The devices can help rehabilitate, reeducate, facilitate normalcy, or augment current functioning. (GLR)

  1. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  2. Virtual Reality Interaction Using Mobile Devices

    KAUST Repository

    Aseeri, Sahar A.

    2013-07-01

    With the use of an immersive display system such as CAVE system, the user is able to realize a 3D immersive virtual environment realistically. However, interacting with virtual worlds in CAVE systems using traditional input devices to perform easy operations such as manipulation, object selection, and navigation is often difficult. This difficulty could diminish the immersion and sense of presence when it comes to 3D virtual environment tasks. Our research aims to implement and evaluate alternative approaches of interaction with immersive virtual environments on mobile devices for manipulation and object selection tasks. As many researchers have noted, using a mobile device as an interaction device has a number of advantages, including built-in display, built-in control, and touch screen facility. These advantages facilitate simple tasks within immersive virtual environments. This research proposes new methods using mobile devices like Smart-phones to perform di↵erent kinds of interactions both as an input device, (e.g. performing selection and manipulation of objects) and as an output device (e.g. utilizing the screen as an extra view for a virtual camera or information display). Moreover, we developed a prototype system to demonstrate and informally evaluate these methods. The research conclusion suggests using mobile devices as a 3D-controller. This will be a more intuitive approach to interact within the virtual environment.

  3. Standardization of splash device

    Science.gov (United States)

    Fernández Raga, María; Peters, Piet

    2017-04-01

    The erosion is a complex process that has been studied extensively by numerous researchers, requiring a prolongued time effort and a large economic investment. To be effective, the measurements of erosion should be precise, controlled and replicable, and to assure efectiveness, measurement devices of erosion should be properly designed, constructed, well calibrated and also they should be operated by a trained person (Stroosnijder, 2005). Because researchers try to improve old devices, the equipment is constantly being redesigned, making the measurements not comparable and furthermore, producing a lack of available standarized device. The lack of standardization of erosion equipment is more obvious in the case of the local splash erosion, where the nature of the process makes very difficult to isolate its effects. In this article we compare the results obtained from five of the most common splash erosion devices (selected from more than 16 different currently types), under the same rain conditions, with the objective of facilitate the standardization of the method that will be more easy to build, minimizing the error. A set of six splash devices were setted in well known positions under simulated rain, to measured the differences, among devices and the accuracy of the data recovered after 10 minutes of rainfall simulation under different intensities (from 60 to 130 mm/h). The rainfall simulator of Wageningen was used, using sand as splash erosion source. Differences in the infiltration were also measured, and a calibration of sizes and speeds of the raindrops was done using the photography method (Hamidreza-Sadeghi et al., 2013). The splash devices selected for this study were unbounded splash devices (like the funnel, the cup (Fernandez-Raga et al., 2010) and the splash flume (Jomaa et al., 2010)), and bounded devices that allow the calculation of splash rate, (like the new cup (Scholten et al., 2011) and the Morgan tray). The behaviour of different splash devices

  4. Historical roots of histrionic personality disorder.

    Science.gov (United States)

    Novais, Filipa; Araújo, Andreia; Godinho, Paula

    2015-01-01

    Histrionic Personality Disorder is one of the most ambiguous diagnostic categories in psychiatry. Hysteria is a classical term that includes a wide variety of psychopathological states. Ancient Egyptians and Greeks blamed a displaced womb, for many women's afflictions. Several researchers from the 18th and 19th centuries studied this theme, namely, Charcot who defined hysteria as a "neurosis" with an organic basis and Sigmund Freud who redefined "neurosis" as a re-experience of past psychological trauma. Histrionic personality disorder (HPD) made its first official appearance in the Diagnostic and Statistical Manual of Mental Disorders II (DSM-II) and since the DSM-III, HPD is the only disorder that kept the term derived from the old concept of hysteria. The subject of hysteria has reflected positions about health, religion and relationships between the sexes in the last 4000 years, and the discussion is likely to continue.

  5. Development of a System for Absolute Quantum Efficiency Determination of Hybrid Photo Diodes

    CERN Document Server

    Hammarstedt, P

    2001-01-01

    At CERN, the European Laboratory for Particle Physics, a new particle accelerator, the Large Hadron Collider (LHC), is under development. The detectors at LHC require development of highly sophisticated technologies, including Hybrid Photo Diodes (HPD) for high efficiency, high resolution single photon detection with a large area coverage. During the HPD development phase, one of the crucial parameters in the optimization of the photocathode creation process is the quantum efficiency. The aim of this Master Thesis has been to design and implement a system for high precision, high resolution quantum efficiency determination over a large, 200-700 nm photon wavelength range. Commercially available components have been obtained, an optomechanical system has been designed and built, and all the necessary data acquisition, control and analysis software has been implemented. The relative precision of the measurement system has been determined to 2%, with additional possible systematic errors less than 2%. Various qu...

  6. Photosensitization of liposomes by porphyrins

    Energy Technology Data Exchange (ETDEWEB)

    Grossweiner, L I; Goyal, G C

    1984-01-01

    Lipid peroxidation was photosensitized in egg phosphatidylcholine (EPC) liposomes by hematoporphyrin (HP), hematoporphyrin derivative (HpD) and uroporphyrin I (Uro-I). Photosensitization by HP was type II via singlet oxygen (/sup 1/O/sub 2/) for the monomeric and dimeric states and type I for aggregated HP. Uro-I was an efficient type II /sup 1/O/sub 2/ photosensitizer. The HpD fraction enriched in the active biological component (HpD-A) was a type II /sup 1/O/sub 2/ photosensitizer at high and low concentrations. The spectral differences between HpD-A in buffer and solubilized in small EPC liposomes are attributed to a conformation change of a key dimer constituent from a folded to a planar geometry. The implications of the results for the action mechanism in photoradiation therapy of tumors with these porphyrins are discussed. 73 references, 1 figure, 5 tables.

  7. Operation control device under radiation exposure

    International Nuclear Information System (INIS)

    Kimura, Kiichi; Murakami, Toichi.

    1994-01-01

    The device of the present invention performs smooth progress of operation by remote control for a plurality of operations in periodical inspections in controlled areas of a nuclear power plant, thereby reducing the operator's exposure dose. Namely, the device monitors the progressing state of the operation by displaying the progress of operation on a CRT of a centralized control device present in a low dose area remote from an operation field through an ITV camera disposed in the vicinity of the operation field. Further, operation sequence and operation instruction procedures previously inputted in the device are indicated to the operation field through an operation instruction outputting device (field CRT) in accordance with the progress of the operation steps. On the other hand, the operation progress can be aided by inputting information from the operation field such as start or completion of the operation steps. Further, the device of the present invention can monitor the change of operation circumstances and exposure dose of operators based on the information from a radiation dose measuring device disposed in the operation circumstance and to individual operators. (I.S.)

  8. Silicon photonics fundamentals and devices

    CERN Document Server

    Deen, M Jamal

    2012-01-01

    The creation of affordable high speed optical communications using standard semiconductor manufacturing technology is a principal aim of silicon photonics research. This would involve replacing copper connections with optical fibres or waveguides, and electrons with photons. With applications such as telecommunications and information processing, light detection, spectroscopy, holography and robotics, silicon photonics has the potential to revolutionise electronic-only systems. Providing an overview of the physics, technology and device operation of photonic devices using exclusively silicon and related alloys, the book includes: * Basic Properties of Silicon * Quantum Wells, Wires, Dots and Superlattices * Absorption Processes in Semiconductors * Light Emitters in Silicon * Photodetectors , Photodiodes and Phototransistors * Raman Lasers including Raman Scattering * Guided Lightwaves * Planar Waveguide Devices * Fabrication Techniques and Material Systems Silicon Photonics: Fundamentals and Devices outlines ...

  9. Devices for collecting chemical compounds

    Science.gov (United States)

    Scott, Jill R; Groenewold, Gary S

    2013-12-24

    A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from a fixed surface so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

  10. Next-Generation Multifunctional Electrochromic Devices.

    Science.gov (United States)

    Cai, Guofa; Wang, Jiangxin; Lee, Pooi See

    2016-08-16

    The rational design and exploration of electrochromic devices will find a wide range of applications in smart windows for energy-efficient buildings, low-power displays, self-dimming rear mirrors for automobiles, electrochromic e-skins, and so on. Electrochromic devices generally consist of multilayer structures with transparent conductors, electrochromic films, ion conductors, and ion storage films. Synthetic strategies and new materials for electrochromic films and transparent conductors, comprehensive electrochemical kinetic analysis, and novel device design are areas of active study worldwide. These are believed to be the key factors that will help to significantly improve the electrochromic performance and extend their application areas. In this Account, we present our strategies to design and fabricate electrochromic devices with high performance and multifunctionality. We first describe the synthetic strategies, in which a porous tungsten oxide (WO3) film with nearly ideal optical modulation and fast switching was prepared by a pulsed electrochemical deposition method. Multiple strategies, such as sol-gel/inkjet printing methods, hydrothermal/inkjet printing methods, and a novel hybrid transparent conductor/electrochromic layer have been developed to prepare high-performance electrochromic films. We then summarize the recent advances in transparent conductors and ion conductor layers, which play critial roles in electrochromic devices. Benefiting from the developments of soft transparent conductive substrates, highly deformable electrochromic devices that are flexible, foldable, stretchable, and wearable have been achieved. These emerging devices have great potential in applications such as soft displays, electrochromic e-skins, deformable electrochromic films, and so on. We finally present a concept of multifunctional smart glass, which can change its color to dynamically adjust the daylight and solar heat input of the building or protect the users' privacy

  11. An Overview of Biofield Devices

    Science.gov (United States)

    Muehsam, David; Chevalier, Gaétan; Barsotti, Tiffany

    2015-01-01

    Advances in biophysics, biology, functional genomics, neuroscience, psychology, psychoneuroimmunology, and other fields suggest the existence of a subtle system of “biofield” interactions that organize biological processes from the subatomic, atomic, molecular, cellular, and organismic to the interpersonal and cosmic levels. Biofield interactions may bring about regulation of biochemical, cellular, and neurological processes through means related to electromagnetism, quantum fields, and perhaps other means of modulating biological activity and information flow. The biofield paradigm, in contrast to a reductionist, chemistry-centered viewpoint, emphasizes the informational content of biological processes; biofield interactions are thought to operate in part via low-energy or “subtle” processes such as weak, nonthermal electromagnetic fields (EMFs) or processes potentially related to consciousness and nonlocality. Biofield interactions may also operate through or be reflected in more well-understood informational processes found in electroencephalographic (EEG) and electrocardiographic (ECG) data. Recent advances have led to the development of a wide variety of therapeutic and diagnostic biofield devices, defined as physical instruments best understood from the viewpoint of a biofield paradigm. Here, we provide a broad overview of biofield devices, with emphasis on those devices for which solid, peer-reviewed evidence exists. A subset of these devices, such as those based upon EEG- and ECG-based heart rate variability, function via mechanisms that are well understood and are widely employed in clinical settings. Other device modalities, such a gas discharge visualization and biophoton emission, appear to operate through incompletely understood mechanisms and have unclear clinical significance. Device modes of operation include EMF-light, EMF-heat, EMF-nonthermal, electrical current, vibration and sound, physical and mechanical, intentionality and nonlocality

  12. Medical devices regulations, standards and practices

    CERN Document Server

    Ramakrishna, Seeram; Wang, Charlene

    2015-01-01

    Medical Devices and Regulations: Standards and Practices will shed light on the importance of regulations and standards among all stakeholders, bioengineering designers, biomaterial scientists and researchers to enable development of future medical devices. Based on the authors' practical experience, this book provides a concise, practical guide on key issues and processes in developing new medical devices to meet international regulatory requirements and standards. Provides readers with a global perspective on medical device regulationsConcise and comprehensive information on how to desig

  13. SOR/72-43 Radiation Emitting Devices Regulations

    International Nuclear Information System (INIS)

    1972-01-01

    These Regulations of 10 February 1972, supplemented by SOR/77-895, lay down the classes of radiation emitting devices for the purposes of the Radiation Emitting Devices Act. They lay down their standards of design and construction and warning sign specifications and provide for the procedure to be followed by inspectors of such devices. The devices include inter alia extra-oral dental x-ray equipment, baggage inspection x-ray devices, laser scanners, television receivers. (NEA)

  14. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Seki, Eiji; Kobayashi, Yoshihiro.

    1989-01-01

    The present invention concerns a device of ionizing radioactive gases to be processed in gaseous nuclear fission products in nuclear fuel reprocessing plants, etc., and injecting them into metal substrates for storage. The device comprises a vessel for a tightly closed type outer electrode in which gases to be processed are introduced, an electrode disposed to the inside of the vessel and the target material, a high DC voltage power source for applying high voltage to the electrodes, etc. There are disposed a first electric discharging portion for preparting discharge plasma for ion injection of different electrode distance and a second electric discharging portion for causing stable discharge between the vessel and the electrode. The first electric discharging portion for the ion injection provides an electrode distance suitable to acceleration sputtering and the second electric discharging portion is used for stable discharge. Accordingly, if the gas pressure in the radioactive gas storage device is reduced by the external disturbance, etc., since the second electric discharging portion satisfies the electric discharging conditions, the device can continue electric discharge. (K.M.)

  15. 21 CFR 882.5940 - Electroconvulsive therapy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroconvulsive therapy device. 882.5940 Section 882.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Electroconvulsive therapy device. (a) Identification. An electroconvulsive therapy device is a device used for...

  16. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  17. Nonimaging radiant energy device

    Science.gov (United States)

    Winston, Roland; Ning, Xiaohui

    1993-01-01

    A nonimaging radiant energy device may include a hyperbolically shaped reflective element with a radiant energy inlet and a radiant energy outlet. A convex lens is provided at the radiant energy inlet and a concave lens is provided at the radiant energy outlet. Due to the provision of the lenses and the shape of the walls of the reflective element, the radiant energy incident at the radiant energy inlet within a predetermined angle of acceptance is emitted from the radiant energy outlet exclusively within an acute exit angle. In another embodiment, the radiant energy device may include two interconnected hyperbolically shaped reflective elements with a respective convex lens being provided at each aperture of the device.

  18. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  19. Medical Devices; Clinical Chemistry and Clinical Toxicology Devices; Classification of the Organophosphate Test System. Final order.

    Science.gov (United States)

    2017-10-18

    The Food and Drug Administration (FDA or we) is classifying the organophosphate test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the organophosphate test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  20. Medical Devices; Hematology and Pathology Devices; Classification of a Cervical Intraepithelial Neoplasia Test System. Final order.

    Science.gov (United States)

    2018-01-03

    The Food and Drug Administration (FDA or we) is classifying the cervical intraepithelial neoplasia (CIN) test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the CIN test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  1. Organic material reducing device in nuclear power plant

    International Nuclear Information System (INIS)

    Minakata, Noriyuki; Takada, Takao

    1998-01-01

    A total organic carbon (TOC) removing device is disposed between a filtration device and a desalting device or between a condensator and the desalting device disposed to a radioactive liquid waste processing facility or a condensate cleaning system of a BWR type nuclear reactor. Since the removing ratio of the TOC removing device is generally high if impurities are not contained, and ionic ingredients are formed after decomposition, TOC can be decomposed and removed more efficiently and removal in a short period of time can be expected by disposing the TOC device downstream of the filtration device or a condensator to be disposed instead of the filtration device and upstream of the desalting device. Then, further enhanced effect can be expected, if two series of the TOC removing line and the bypass line are disposed between the filtration device or the condensator and the desalting device so as to enable selection of processed liquids. (T.M.)

  2. 77 FR 65580 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-10-29

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-856] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International...

  3. Flexible spin-orbit torque devices

    Energy Technology Data Exchange (ETDEWEB)

    Lee, OukJae; You, Long; Jang, Jaewon; Subramanian, Vivek [Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California 94720 (United States); Salahuddin, Sayeef [Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2015-12-21

    We report on state-of-the-art spintronic devices synthesized and fabricated directly on a flexible organic substrate. Large perpendicular magnetic anisotropy was achieved in ultrathin ferromagnetic heterostructures of Pt/Co/MgO sputtered on a non-rigid plastic substrate at room temperature. Subsequently, a full magnetic reversal of the Co was observed by exploiting the spin orbit coupling in Pt that leads to a spin accumulation at the Pt/Co interface when an in-plane current is applied. Quasi-static measurements show the potential for operating these devices at nano-second speeds. Importantly, the behavior of the devices remained unchanged under varying bending conditions (up to a bending radius of ≈ ±20–30 mm). Furthermore, the devices showed robust operation even after application of 10{sup 6} successive pulses, which is likely sufficient for many flexible applications. Thus, this work demonstrates the potential for integrating high performance spintronic devices on flexible substrates, which could lead to many applications ranging from flexible non-volatile magnetic memory to local magnetic resonance imaging.

  4. Flexible spin-orbit torque devices

    International Nuclear Information System (INIS)

    Lee, OukJae; You, Long; Jang, Jaewon; Subramanian, Vivek; Salahuddin, Sayeef

    2015-01-01

    We report on state-of-the-art spintronic devices synthesized and fabricated directly on a flexible organic substrate. Large perpendicular magnetic anisotropy was achieved in ultrathin ferromagnetic heterostructures of Pt/Co/MgO sputtered on a non-rigid plastic substrate at room temperature. Subsequently, a full magnetic reversal of the Co was observed by exploiting the spin orbit coupling in Pt that leads to a spin accumulation at the Pt/Co interface when an in-plane current is applied. Quasi-static measurements show the potential for operating these devices at nano-second speeds. Importantly, the behavior of the devices remained unchanged under varying bending conditions (up to a bending radius of ≈ ±20–30 mm). Furthermore, the devices showed robust operation even after application of 10 6 successive pulses, which is likely sufficient for many flexible applications. Thus, this work demonstrates the potential for integrating high performance spintronic devices on flexible substrates, which could lead to many applications ranging from flexible non-volatile magnetic memory to local magnetic resonance imaging

  5. 21 CFR 864.6400 - Hematocrit measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematocrit measuring device. 864.6400 Section 864.6400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6400 Hematocrit measuring...

  6. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  7. Employment of mobile devices in chemistry education

    OpenAIRE

    Švehla, Martin

    2013-01-01

    This diploma thesis is focused on the use of mobile devices in chemistry education. Describes various mobile devices, including different operating systems and technology and shows huge potential that these devices bring to education. It also includes an overview of existing educational programs with a chemical theme on mobile devices. Part of this work was to create a custom supportive program Chemical helper for mobile devices, which can be used in chemistry education, laboratory and also i...

  8. Non-logic devices in logic processes

    CERN Document Server

    Ma, Yanjun

    2017-01-01

    This book shows readers how to design semiconductor devices using the most common and lowest cost logic CMOS processes.  Readers will benefit from the author’s extensive, industrial experience and the practical approach he describes for designing efficiently semiconductor devices that typically have to be implemented using specialized processes that are expensive, time-consuming, and low-yield. The author presents an integrated picture of semiconductor device physics and manufacturing techniques, as well as numerous practical examples of device designs that are tried and true.

  9. Fabrication of coplanar HF analog devices

    International Nuclear Information System (INIS)

    Schulz, G.; Kratz, H.

    1993-01-01

    A thin film technology has to be built up, which allows the reliable and reproducible production of such devices. This technology has to fulfill some general requirements and many specific ones due to the difference of the devices. The general requirements concern the suitability of the technology for industrial production. That means, that the production processes should be reliable, they should allow a high trough-put, and up-scaling should be possible. Processes as passivation or cryo-packaging of the devices belong to this group of requirements as well. The technology for fabrication of the devices splits up into three well distinguishable techniques: deposition of thin films, control of the quality of the deposited layers and patterning of the device structures and contacts. (orig.)

  10. Organic optoelectronics:materials,devices and applications

    Institute of Scientific and Technical Information of China (English)

    LIU Yi; CUI Tian-hong

    2005-01-01

    The interest in organic materials for optoelectronic devices has been growing rapidly in the last two decades. This growth has been propelled by the exciting advances in organic thin films for displays, low-cost electronic circuits, etc. An increasing number of products employing organic electronic devices have become commercialized, which has stimulated the age of organic optoelectronics. This paper reviews the recent progress in organic optoelectronic technology. First, organic light emitting electroluminescent materials are introduced. Next, the three kinds of most important organic optoelectronic devices are summarized, including light emitting diode, organic photovoltaic cell, and photodetectors. The various applications of these devices are also reviewed and discussed in detail. Finally, the market and future development of optoelectronic devices are also demonstrated.

  11. Design of wearable health monitoring device

    Science.gov (United States)

    Devara, Kresna; Ramadhanty, Savira; Abuzairi, Tomy

    2018-02-01

    Wearable smart health monitoring devices have attracted considerable attention in both research community and industry. Some of the causes are the increasing healthcare costs, along with the growing technology. To address this demand, in this paper, design and evaluation of wearable health monitoring device integrated with smartphone were presented. This device was designed for patients in need of constant health monitoring. The performance of the proposed design has been tested by conducting measurement once in 2 minutes for 10 minutes to obtain heart rate and body temperature data. The comparation between data measured by the proposed device and that measured by the reference device yields only an average error of 1.45% for heart rate and 1.04% for body temperature.

  12. Cross-Device Tracking: Measurement and Disclosures

    Directory of Open Access Journals (Sweden)

    Brookman Justin

    2017-04-01

    Full Text Available Internet advertising and analytics technology companies are increasingly trying to find ways to link behavior across the various devices consumers own. This cross-device tracking can provide a more complete view into a consumer’s behavior and can be valuable for a range of purposes, including ad targeting, research, and conversion attribution. However, consumers may not be aware of how and how often their behavior is tracked across different devices. We designed this study to try to assess what information about cross-device tracking (including data flows and policy disclosures is observable from the perspective of the end user. Our paper demonstrates how data that is routinely collected and shared online could be used by online third parties to track consumers across devices.

  13. The homogentisate pathway: a central catabolic pathway involved in the degradation of L-phenylalanine, L-tyrosine, and 3-hydroxyphenylacetate in Pseudomonas putida.

    Science.gov (United States)

    Arias-Barrau, Elsa; Olivera, Elías R; Luengo, José M; Fernández, Cristina; Galán, Beatriz; García, José L; Díaz, Eduardo; Miñambres, Baltasar

    2004-08-01

    Pseudomonas putida metabolizes Phe and Tyr through a peripheral pathway involving hydroxylation of Phe to Tyr (PhhAB), conversion of Tyr into 4-hydroxyphenylpyruvate (TyrB), and formation of homogentisate (Hpd) as the central intermediate. Homogentisate is then catabolized by a central catabolic pathway that involves three enzymes, homogentisate dioxygenase (HmgA), fumarylacetoacetate hydrolase (HmgB), and maleylacetoacetate isomerase (HmgC), finally yielding fumarate and acetoacetate. Whereas the phh, tyr, and hpd genes are not linked in the P. putida genome, the hmgABC genes appear to form a single transcriptional unit. Gel retardation assays and lacZ translational fusion experiments have shown that hmgR encodes a specific repressor that controls the inducible expression of the divergently transcribed hmgABC catabolic genes, and homogentisate is the inducer molecule. Footprinting analysis revealed that HmgR protects a region in the Phmg promoter that spans a 17-bp palindromic motif and an external direct repetition from position -16 to position 29 with respect to the transcription start site. The HmgR protein is thus the first IclR-type regulator that acts as a repressor of an aromatic catabolic pathway. We engineered a broad-host-range mobilizable catabolic cassette harboring the hmgABC, hpd, and tyrB genes that allows heterologous bacteria to use Tyr as a unique carbon and energy source. Remarkably, we show here that the catabolism of 3-hydroxyphenylacetate in P. putida U funnels also into the homogentisate central pathway, revealing that the hmg cluster is a key catabolic trait for biodegradation of a small number of aromatic compounds.

  14. Phylogeny of Dengue and Chikungunya viruses in Al Hudayda governorate, Yemen.

    Science.gov (United States)

    Ciccozzi, Massimo; Lo Presti, Alessandra; Cella, Eleonora; Giovanetti, Marta; Lai, Alessia; El-Sawaf, Gamal; Faggioni, Giovanni; Vescio, Fenicia; Al Ameri, Ranya; De Santis, Riccardo; Helaly, Ghada; Pomponi, Alice; Metwally, Dalia; Fantini, Massimo; Qadi, Hussein; Zehender, Gianguglielmo; Lista, Florigio; Rezza, Giovanni

    2014-10-01

    Yemen, which is located in the southwestern end of the Arabian Peninsula, is one of countries most affected by recurrent epidemics caused by emerging vector-borne viruses. Dengue virus (DENV) outbreaks have been reported with increasing frequency in several governorates since the year 2000, and the Chikungunya virus (CHIKV) has been also responsible of large outbreaks and it is now a major public health problem in Yemen. We report the results of the phylogenetic analysis of DENV-2 and CHIKV isolates (NS1 and E1 genes, respectively) detected in an outbreak occurred in Al-Hudayda in 2012. Estimates of the introduction date of CHIKV and DENV-2, and the phylogeographic analysis of DENV-2 are also presented. Phylogenetic analysis showed that the Yemen isolates of DENV belonged to the lineage 2 Cosmopolitan subtype, whereas CHIKV isolates from Yemen belonged to the ECSA genotype. All the CHIKV isolates from Yemen were statistically supported and dated back to the year 2010 (95% HPD: 2009-2011); these sequences showed an alanine in the aminoacid position 226 of the E1 protein. Phylogeographic analysis of DENV-2 virus showed that cluster 1, which included Yemen isolates, dated back to 2003 Burkina Faso strains (95% HPD 1999-2007). The Yemen, cluster dated back to 2011 (95% HPD 2009-2012). Our study sheds light on the global spatiotemporal dynamics of DENV-2 and CHIKV in Yemen. This study reinforces both the need to monitor the spread of CHIKV and DENV, and to apply significant measures for vector control. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Chronic effects of ambient air pollution on respiratory morbidities among Chinese children: a cross-sectional study in Hong Kong.

    Science.gov (United States)

    Gao, Yang; Chan, Emily Yy; Li, Liping; Lau, Patrick Wc; Wong, Tze Wai

    2014-02-03

    The chronic health effects from exposure to ambient air pollution are still unclear. This study primarily aims to examine the relationship between long-term exposure to ambient air pollution and respiratory morbidities in Chinese children. A cross-sectional study was conducted among 2,203 school children aged 8-10 in three districts with different air pollution levels in Hong Kong. Annual means for ambient PM10, SO2, NO2 and O3 in each district were used to estimate participants' individual exposure. Two questionnaires were used to collect children's respiratory morbidities and other potential risk factors. Multivariable logistic regression was fitted to estimate the risks of air pollution for respiratory morbidities. Compared to those in the low-pollution district (LPD), girls in the high-pollution district (HPD) were at significantly higher risk for cough at night (ORadj. = 1.81, 95% CI: 1.71-2.78) and phlegm without colds (ORadj. = 3.84, 95% CI: 1.74-8.47). In addition, marginal significance was reached for elevated risks for asthma, wheezing symptoms, and phlegm without colds among boys in HPD (adjusted ORs: 1.71-2.82), as well as chronic cough among girls in HPD (ORadj. = 2.03, 95% CI: 0.88-4.70). Results have confirmed certain adverse effects on children's respiratory health from long-term exposure to ambient air pollution. PM10 may be the most relevant pollutant with adverse effects on wheezing and phlegm in boys. Both PM10 and NO2 may be contributing to cough and phlegm in girls.

  16. Evolution of the intercontinental disjunctions in six continents in the Ampelopsis clade of the grape family (Vitaceae)

    Science.gov (United States)

    2012-01-01

    Background The Ampelopsis clade (Ampelopsis and its close allies) of the grape family Vitaceae contains ca. 43 species disjunctly distributed in Asia, Europe, North America, South America, Africa, and Australia, and is a rare example to study both the Northern and the Southern Hemisphere intercontinental disjunctions. We reconstruct the temporal and spatial diversification of the Ampelopsis clade to explore the evolutionary processes that have resulted in their intercontinental disjunctions in six continents. Results The Bayesian molecular clock dating and the likelihood ancestral area analyses suggest that the Ampelopsis clade most likely originated in North America with its crown group dated at 41.2 Ma (95% HPD 23.4 - 61.0 Ma) in the middle Eocene. Two independent Laurasian migrations into Eurasia are inferred to have occurred in the early Miocene via the North Atlantic land bridges. The ancestor of the Southern Hemisphere lineage migrated from North America to South America in the early Oligocene. The Gondwanan-like pattern of intercontinental disjunction is best explained by two long-distance dispersals: once from South America to Africa estimated at 30.5 Ma (95% HPD 16.9 - 45.9 Ma), and the other from South America to Australia dated to 19.2 Ma (95% HPD 6.7 - 22.3 Ma). Conclusions The global disjunctions in the Ampelopsis clade are best explained by a diversification model of North American origin, two Laurasian migrations, one migration into South America, and two post-Gondwanan long-distance dispersals. These findings highlight the importance of both vicariance and long distance dispersal in shaping intercontinental disjunctions of flowering plants. PMID:22316163

  17. Origin and evolutionary dynamics of Hepatitis B virus (HBV) genotype E in Madagascar.

    Science.gov (United States)

    Lo Presti, Alessandra; Andriamandimby, Soa Fy; Lai, Alessia; Angeletti, Silvia; Cella, Eleonora; Mottini, Giovanni; Guarino, Michele Pier Luca; Balotta, Claudia; Galli, Massimo; Heraud, Jean-Michel; Zehender, Gianguglielmo; Ciccozzi, Massimo

    2017-02-01

    Africa is one of the endemic regions of HBV infection. In particular, genotype E is highly endemic in most of sub-Saharan Africa such as West African countries where it represents more than 90% of total infections. Madagascar, which is classified as a high endemic area for HBV and where the most prevalent genotype is E, might play a relevant role in the dispersion of this genotype due to its crucial position in the Indian Ocean. The aim of this study was to investigate the origin, population dynamics, and circulation of HBV-E genotype in Madagascar through high-resolution phylogenetic and phylodynamic approaches. The phylogenetic tree indicated that Malagasy isolates were intermixed and closely related with sequences mostly from West African countries. The Bayesian tree highlighted three statistically supported clusters of Malagasy strains which dated back to the years 1981 (95% HPD: 1971-1992), 1986 (95% HPD: 1974-1996), and 1989 (95% HPD: 1974-2001). Population dynamics analysis showed an exponential increase in the number of HBV-E infections approximately from the year 1975 until 2000s. The migration analysis was also performed and a dynamic pattern of gene flow was identified. In conclusion, this study confirms previous observation of HBV-E circulation in Africa and expands these findings at Madagascar demonstrating its recent introduction, and highlighting the role of the African countries in the spread of HBV-E genotype. Further studies on molecular epidemiology of HBV genotype E are needed to clarify the evolutionary history of this genotype.

  18. Molecular phylogenetic analysis of the Persea group (Lauraceae) and its biogeographic implications on the evolution of tropical and subtropical Amphi-Pacific disjunctions.

    Science.gov (United States)

    Li, Lang; Li, Jie; Rohwer, Jens G; van der Werff, Henk; Wang, Zhi-Hua; Li, Hsi-Wen

    2011-09-01

    The Persea group (Lauraceae) has a tropical and subtropical amphi-pacific disjunct distribution with most of its members, and it includes two Macaronesian species. The relationships within the group are still controversial, and its intercontinental disjunction has not been investigated with extensive sampling and precise time dating. • ITS and LEAFY intron II sequences of 78 Persea group species and nine other Lauraceae species were analyzed with maximum parsimony and Bayesian inference. Divergence time estimation employed Bayesian Markov chain Monte Carlo method under a relaxed clock. • Several traditional genera or subgenera within the Persea group form well-supported monophyletic groups except Alseodaphne and Dehaasia. The divergence time of the Persea group is estimated as ∼55.3 (95% higher posterior densities [HPD] 41.4-69.9) million years ago (mya). Two major divergences within the Persea group are estimated as ∼51.9 (95% HPD 38.9-63.9) mya and ∼48.5 (95% HPD 35.9-59.9) mya. • Persea can be retained as a genus by the inclusion of Apollonias barbujana and exclusion a few species that do not fit into the established subgenera. A major revision is recommended for the delimitation between Alseodaphne, Dehaasia, and Nothaphoebe. We suggest that the Persea group originated from the Perseeae-Laureae radiation in early Eocene Laurasia. Its amphi-pacific disjunction results from the disruption of boreotropical flora by climatic cooling during the mid- to late Eocene. The American-Macaronesian disjunction may be explained by the long-distance dispersal.

  19. Psychological, situational and application-related determinants of the intention to self-test: a factorial survey among students.

    Science.gov (United States)

    Kuecuekbalaban, Pinar; Rostalski, Tim; Schmidt, Silke; Muehlan, Holger

    2017-07-10

    The Internet enables an unprecedented opportunity to access a broad range of self-tests (e.g. testing for HIV, cancer, hepatitis B/C), which can be conducted by lay consumers without the help of a health professional. However, there is only little knowledge about the determinants of the use of self-tests. Thus, the aims of this study were (1) to experimentally investigate the impact of situational and application-related characteristics on the intention to use a self-test (ST), compared to being tested by a health professional at home (HPH) or at a doctor's office (HPD), (2) to examine the applicability of social-cognitive health behaviour theories on self-testing, and (3) to explore the advantages of integrating technological affinity into social-cognitive health behaviour models to predict self-testing. In a factorial survey, 1248 vignettes were rated by 208 students. The core concepts of social-cognitive health behaviour theories, technological affinity, and different situational and application-related characteristics were investigated. Intention to ST was only predicted by the medical expertise of the tested person, while HPH and HPD were also associated with the application purpose of the test and the presence of an emotionally supporting person. Perceived severity and outcome-expectancy significantly predicted intention to self-test. Technological enthusiastic people had a higher intention to use a self-test. Intention to ST, HPH and HPD were predicted by different situational and application-related characteristics. Social-cognitive health behaviour theories can be applied to predict self-testing and do not need to be extended by technological affinity.

  20. Intra-uterine contraceptive devices.

    Science.gov (United States)

    Elias, J

    1985-05-01

    Among the advantages of IUDs are the device's high continuation rate, the lack of systemic side effects, and the absence of a need for continual motivation to practice contraception. The effectiveness of plastic IUDs is directly proportional to their surface area, but the degree of excessive bleeding experienced is inversely related to device size. Thus, devices represent a compromise between large size for effectiveness and small size for acceptability. The optimum time to fit an IUD is during the 1st hald of the menstrual cycle. Absolute contraindications to IUD use include the presence of active pelvic inflammatory disease, undiagnosed irregular bleeding, a history of ectopic pregnancy or tubal surgery, and a distorted uteine cavity. Failure rates associated with IUD use range from 2-3% in the 1st year and then decrease. Since the main mechanism of action appears to be production of a sterile inflammatory reaction in the uterine cavity, the IUD prevents intrauterine pregnancy more effectively than ectopic pregnancy. Nonetheless, there is little evidence to suggest that IUD use actually increases the incidence of ectopic pregnancy. Resumption of fertility after IUD removal is not delayed. There is not need to change inert plastic IUDs in women who remain symptom free. The copper devices should be changed every 3-4 years. A search is under way for antifertility agents that can be incorporated into the device to reduce side effects. In general, the IUD is most suitable for older, parous women.