WorldWideScience

Sample records for house dust concentrations

  1. Lead in Chinese villager house dust: Geographical variation and influencing factors

    International Nuclear Information System (INIS)

    Bi, Xiangyang; Liu, Jinling; Han, Zhixuan; Yang, Wenlin

    2015-01-01

    House dust has been recognized as an important contributor to Pb exposure of children. Here we conducted a comprehensive study to investigate geographical variation of Pb in Chinese villager house dust. The influences of outdoor soil Pb concentrations, dates of construction, house decoration materials, heating types, and site specific pollution on Pb concentrations in house dust were evaluated. The concentrations of Pb in 477 house dust samples collected from twenty eight areas throughout China varied from 12 to 2510 mg/kg, with a median concentration of 42 mg/kg. The median Pb concentrations in different geographical areas ranged from 16 (Zhangjiakou, Hebei) to 195 mg/kg (Loudi, Hunan). No correlations were found between the house dust Pb concentrations and the age of houses, as well as house decoration materials. Whereas outdoor soil, coal combustion, and site specific pollution may be potential Pb sources. Principal component analysis (PCA) confirmed that elemental compositions of the house dust were controlled by both anthropogenic and geogenic sources. Using scanning electron microscopy (SEM), the Pb bearing particles in the house dust were also studied. - Highlights: • Geographical variation in house dust Pb concentrations were observed. • Dust Pb concentrations were not associated with house age and decoration materials. • Soil, coal combustion, and site specific pollution were potential Pb sources. • Pb bearing particles were identified by SEM-EDX. - The variations of Pb in Chinese villager house dust were controlled by outdoor soil, coal combustion, and site specific pollution sources.

  2. Lead in Chinese villager house dust: Geographical variation and influencing factors.

    Science.gov (United States)

    Bi, Xiangyang; Liu, Jinling; Han, Zhixuan; Yang, Wenlin

    2015-12-01

    House dust has been recognized as an important contributor to Pb exposure of children. Here we conducted a comprehensive study to investigate geographical variation of Pb in Chinese villager house dust. The influences of outdoor soil Pb concentrations, dates of construction, house decoration materials, heating types, and site specific pollution on Pb concentrations in house dust were evaluated. The concentrations of Pb in 477 house dust samples collected from twenty eight areas throughout China varied from 12 to 2510 mg/kg, with a median concentration of 42 mg/kg. The median Pb concentrations in different geographical areas ranged from 16 (Zhangjiakou, Hebei) to 195 mg/kg (Loudi, Hunan). No correlations were found between the house dust Pb concentrations and the age of houses, as well as house decoration materials. Whereas outdoor soil, coal combustion, and site specific pollution may be potential Pb sources. Principal component analysis (PCA) confirmed that elemental compositions of the house dust were controlled by both anthropogenic and geogenic sources. Using scanning electron microscopy (SEM), the Pb bearing particles in the house dust were also studied. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. The management of house dust mite allergies

    NARCIS (Netherlands)

    Bronswijk, van J.E.M.H.; Schober, G.; Kniest, F.M.

    1990-01-01

    A safe and practical home sanitation procedure for the removal of house dust mites (Dermatophagoides pteronyssinus) and their allergens is described. The severity of mite infestation was assessed with the use of the Acarex test, which measures the concentration of guanine in house dust, and all

  4. Seasonal and occupational trends of five organophosphate pesticides in house dust.

    Science.gov (United States)

    Smith, Marissa N; Workman, Tomomi; McDonald, Katie M; Vredevoogd, Melinda A; Vigoren, Eric M; Griffith, William C; Thompson, Beti; Coronado, Gloria D; Barr, Dana; Faustman, Elaine M

    2017-07-01

    Since 1998, the University of Washington's Center for Child Environmental Health Risks Research has followed a community-based participatory research strategy in the Lower Yakima Valley of Washington State to assess pesticide exposure among families of Hispanic farmworkers. As a part of this longitudinal study, house dust samples were collected from both farmworker and non-farmworker households, across three agricultural seasons (thinning, harvest and non-spray). The household dust samples were analyzed for five organophosphate pesticides: azinphos-methyl, phosmet, malathion, diazinon, and chlorpyrifos. Organophosphate pesticide levels in house dust were generally reflective of annual use rates and varied by occupational status and agricultural season. Overall, organophosphate pesticide concentrations were higher in the thinning and harvest seasons than in the non-spray season. Azinphos-methyl was found in the highest concentrations across all seasons and occupations. Farmworker house dust had between 5- and 9-fold higher concentrations of azinphos-methyl than non-farmworker house dust. Phosmet was found in 5-7-fold higher concentrations in farmworker house dust relative to non-farmworker house dust. Malathion and chlorpyriphos concentrations in farmworker house dust ranged between 1.8- and 9.8-fold higher than non-farmworker house dust. Diazinon showed a defined seasonal pattern that peaked in the harvest season and did not significantly differ between farmworker and non-farmworker house dust. The observed occupational differences in four out of five of the pesticide residues measured provides evidence supporting an occupational take home pathway, in which workers may bring pesticides home on their skin or clothing. Further, these results demonstrate the ability of dust samples to inform the episodic nature of organophosphate pesticide exposures and the need to collect multiple samples for complete characterization of exposure potential.

  5. Canadian House Dust Study: Population-based concentrations, loads and loading rates of arsenic, cadmium, chromium, copper, nickel, lead, and zinc inside urban homes

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Pat E. [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Levesque, Christine [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Chénier, Marc; Gardner, H. David [Exposure and Biomonitoring Division, Healthy Environments and Consumer Safety Branch, Health Canada, 50 Colombine Driveway, Ottawa, ON, Canada K1A 0K9 (Canada); Department of Earth Sciences, University of Ottawa, 140 Louis Pasteur, Ottawa, ON, Canada K1N 6N5 (Canada); Jones-Otazo, Heather [Regions and Programs Branch, Health Canada, 180 Queen Street West, Toronto, ON, Canada M5V 3L7 (Canada); Petrovic, Sanya [Contaminated Sites Division, Healthy Environments and Consumer Safety Branch, Health Canada, 269 Laurier Ave West, Ottawa, ON, Canada K1A 0K9 (Canada)

    2013-01-15

    The Canadian House Dust Study was designed to obtain nationally representative urban house dust metal concentrations (μg g{sup −1}) and metal loadings (μg m{sup −2}) for arsenic (As), cadmium (Cd), chromium (Cr), copper (Cu), nickel (Ni), lead (Pb), and zinc (Zn). Consistent sampling of active dust of known age and provenance (area sampled) also permitted the calculation of indoor loading rates (mg m{sup −2} day{sup −1} for dust and μg m{sup −2} day{sup −1} for metals) for the winter season (from 2007 to 2010) when houses are most tightly sealed. Geomean/median indoor dust loading rates in homes located more than 2 km away from industry of any kind (9.6/9.1 mg m{sup −2} day{sup −1}; n = 580) were significantly lower (p < .001) than geomean (median) dust loading rates in homes located within 2 km of industry (13.5/13.4 mg m{sup −2} day{sup −1}; n = 421). Proximity to industry was characterized by higher indoor metal loading rates (p < .003), but no difference in dust metal concentrations (.29 ≥ p ≤ .97). Comparisons of non-smokers' and smokers' homes in non-industrial zones showed higher metal loading rates (.005 ≥ p ≤ .038) in smokers' homes, but no difference in dust metal concentrations (.15 ≥ p ≤ .97). Relationships between house age and dust metal concentrations were significant for Pb, Cd and Zn (p < .001) but not for the other four metals (.14 ≥ p ≤ .87). All seven metals, however, displayed a significant increase in metal loading rates with house age (p < .001) due to the influence of higher dust loading rates in older homes (p < .001). Relationships between three measures of metals in house dustconcentration, load, and loading rate – in the context of house age, smoking behavior and urban setting consistently show that concentration data is a useful indicator of the presence of metal sources in the home, whereas dust mass is the overriding influence on metal loadings and loading rates

  6. House dust-mite allergen exposure is associated with serum specific IgE but not with respiratory outcomes.

    Science.gov (United States)

    Bakolis, I; Heinrich, J; Zock, J P; Norbäck, D; Svanes, C; Chen, C M; Accordini, S; Verlato, G; Olivieri, M; Jarvis, D

    2015-06-01

    Exposure to house dust has been associated with asthma in adults, and this is commonly interpreted as a direct immunologic response to dust-mite allergens in those who are IgE sensitized to house dust-mite. Mattress house dust-mite concentrations were measured in a population-based sample of 2890 adults aged between 27 and 56 years living in 22 centers in 10 countries. Generalized linear mixed models were employed to explore the association of respiratory symptoms with house dust-mite concentrations, adjusting for individual and household confounders. There was no overall association of respiratory outcomes with measured house dust-mite concentrations, even in those who reported they had symptoms on exposure to dust and those who had physician-diagnosed asthma. However, there was a positive association of high serum specific IgE levels to HDM (>3.5 kUA /l) with mattress house dust-mite concentrations and a negative association of sensitization to cat with increasing house dust-mite concentrations. In conclusion, there was no evidence that respiratory symptoms in adults were associated with exposure to house dust-mite allergen in the mattress, but an association of house mite with strong sensitization was observed. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. House dust extracts contain potent immunological adjuvants

    NARCIS (Netherlands)

    Beukelman, C.J.; Dijk, H. van; Aerts, P.C.; Rademaker, P.M.; Berrens, L.; Willers, J.M.N.

    1987-01-01

    A crude aqueous extract of house dust and two house dust subfractions were tested for adjuvant activity in a sensitivity assay performed in mice. Evidence is presented that house dust contains at least two potent immunological adjuvants. One of these, present in both subfractions, was probably

  8. Farmers' exposure to dusts and gases in modern Finnish cubicle cow houses

    Directory of Open Access Journals (Sweden)

    K. LOUHELAINEN

    2008-12-01

    Full Text Available The occurrence of airborne dust, gases, microbes, endotoxin and bovine epithelial antigens (BEA, BDA20 was studied in 26 modern, mainly cubicle, cow houses. Air samples of total dust, total spores, endotoxin and bovine epithelial allergens were collected on membrane filters with portable or piston pumps and analyzed with appropriate methods. Concentrations of gases (ammonia, carbon dioxide, hydrogen sulfide were measured with diffusion tubes. Airborne viable spores were collected with a cascade impactor on five selective culture media for the identification of xerophilic, mesophilic and thermotolerant fungi and thermophilic actinomycetes. The geometric mean concentrations of total dust, BEA and BDA20 were 0.2-1.9 mg/m 3 , 5.2- 9.7 mg/m 3 and 50-260 ng/m 3 , respectively. The mean concentrations of ammonia and carbon dioxide were between 2.8-15 ppm and 2200-3200 ppm, respectively. The geometric mean of endotoxins was 19 ng/m 3 and the concentrations of fungi were at the 10 1 -10 3 cfu/m 3 level. In general, the variation in concentrations of total dust, viable fungi and endotoxin was large. The concentrations of total dust and fungi were lower than in earlier studies. Thus new cubicle houses provide a better working environment with regard to airborne hazards than the traditional cow houses.;

  9. Stability evaluation of house dust mite vaccines for sublingual immunotherapy

    Directory of Open Access Journals (Sweden)

    MARIJA GAVROVIĆ-JANKULOVIĆ

    2010-01-01

    Full Text Available Allergen-specific immunotherapy with house dust mite (HDM allergen extracts can effectively alleviate the symptoms of allergic rhinitis and asthma. The efficacy of the immunotherapeutic treatment is highly dependent on the quality of house dust mite vaccines. This study was performed to assess the stability of house dust mite allergen vaccines prepared for sublingual immunotherapy. Lyophilized Dermatophagoides pteronyssinus (Dpt mite bodies were the starting material for the production of sublingual vaccines in four therapeutic concentrations. The stability of the extract for vaccine production, which was stored below 4 °C for one month, showed consistence in the protein profile in SDS PAGE. ELISA-inhibition showed that the potencies of Dpt vaccines during a 12 month period were to 65–80 % preserved at all analyzed therapeutic concentrations. This study showed that glycerinated Dpt vaccines stored at 4 °C preserved their IgE-binding potential during a 12 month period, implying their suitability for sublingual immunotherapeutic treatment of HDM allergy.

  10. Concentration of the genera Aspergillus, Eurotium and Penicillium in 63-μm house dust fraction as a method to predict hidden moisture damage in homes

    Directory of Open Access Journals (Sweden)

    Assadian Ojan

    2009-07-01

    Full Text Available Abstract Background Quantitative measurements of mould enrichment of indoor air or house dust might be suitable surrogates to evaluate present but hidden moisture damage. Our intent was to develop a house-dust monitoring method to detect hidden moisture damage excluding the influence of outdoor air, accumulated old dust, and dust swirled up from room surfaces. Methods Based on standardized measurement of mould spores in the 63-μm fraction of house dust yielded by carpets, the background concentrations were determined and compared to simultaneously obtained colony numbers and total spore numbers of the indoor air in 80 non-mouldy living areas during summer and winter periods. Additionally, sampling with a vacuum-cleaner or manual sieve was compared to sampling with a filter holder or sieving machine, and the evaluative power of an established two-step assessment model (lower and upper limits was compared to that of a one-step model (one limit in order to derive concentration limits for mould load in house dust. Results Comparison with existing evaluation procedures proved the developed method to be the most reliable means of evaluating hidden moisture damage, yielding the lowest false-positive results (specificity 98.7%. Background measurements and measurements in 14 mouldy rooms show that even by evaluating just the indicator genera in summer and winter, a relatively certain assessment of mould infestation is possible. Conclusion A one-step evaluation is finally possible for house dust. The house-dust evaluation method is based on analysis of the indicator genera Aspergillus, Eurotium and Penicillium spp., which depend on the total fungal count. Inclusion of further moisture indicators currently appears questionable, because of outdoor air influence and the paucity of measurements.

  11. Determinants, reproducibility, and seasonal variation of ergosterol levels in house dust.

    Science.gov (United States)

    Leppänen, H K; Nevalainen, A; Vepsäläinen, A; Roponen, M; Täubel, M; Laine, O; Rantakokko, P; von Mutius, E; Pekkanen, J; Hyvärinen, A

    2014-06-01

    This study aimed to clarify the determinants that affect the concentrations of ergosterol and viable fungi in house dust and to examine the seasonal variation and reproducibility of ergosterol concentrations indoors. In studying the determinants, dust samples from living room floors and vacuum cleaner dust bags were collected from 107 farming and 105 non-farming homes. Ergosterol levels were determined with gas chromatography-mass spectrometry,and the dust bag dust was cultivated for enumeration of fungal genera. Lifestyle and environmental factors, for example using of the fireplace, and visible mold observations in homes, explained 20–26% of the variation of fungal concentrations. For the reproducibility study, samples were collected from five urban homes in four different seasons. The reproducibility of ergosterol determinations within a sample was excellent (ICC = 89.8) for floor dust and moderate (ICC = 63.8) for dust bag dust, but poor when sampling the same home throughout a year (ICC = 31.3 and 12.6, respectively) due to large temporal variation in ergosterol concentrations. In conclusion, environmental characteristics only partially predicted the variation of fungal concentrations. Based on these studies, we recommend repeated sampling of dust over time if one seeks to adequately describe overall fungal levels and exposure in a home. This study shows that levels of ergosterol and viable fungi in house dust are related to visible mold observations. Only 20% of the variation in fungal levels can be explained with questionnaires, and therefore, environmental samples need to be taken in addition. Reproducibility of ergosterol determination was excellent for floor dust, and thus, ergosterol measurements from floor dust samples could be suitable for assessing the fungal load in building investigations. The temporal variation needs to be taken into account when describing the ergosterol concentration of urban homes.

  12. Radionuclides in house dust

    Energy Technology Data Exchange (ETDEWEB)

    Fry, F A; Green, N; Dodd, N J; Hammond, D J

    1985-04-01

    Discharges of radionuclides from the British Nuclear Fuel plc (BNFL) reprocessing plant at Sellafield in Cumbria have led to elevated concentrations radionuclides in the local environment. The major routes of exposure of the public are kept under review by the appropriate authorising Government departments and monitoring is carried out both by the departments and by BNFL itself. Recently, there has been increasing public concern about general environmental contamination resulting from the discharges and, in particular, about possible exposure of members of the public by routes not previously investigated in detail. One such postulated route of exposure that has attracted the interest of the public, the press and Parliament arises from the presence of radionuclides within houses. In view of this obvious and widespread concern, the Board has undertaken a sampling programme in a few communities in Cumbria to assess the radiological significance of this source of exposure. From the results of our study, we conclude that, although radionuclides originating rom the BNFL site can be detected in house dust, this source of contamination is a negligible route of exposure for members of the public in West Cumbria. This report presents the results of the Board's study of house dust in twenty homes in Cumbria during the spring and summer of 1984. A more intensive investigation is being carried out by Imperial College. (author)

  13. Clinical benefits of treatment with SQ house dust mite sublingual tablet in house dust mite allergic rhinitis.

    Science.gov (United States)

    Demoly, P; Kleine-Tebbe, J; Rehm, D

    2017-10-01

    Treatment with SQ (standardised quality) house dust mite sublingual tablet for 1 year resulted in a decreased probability of having an allergic rhinitis (AR) exacerbation day (from 11% [placebo] to 5% [SQ house dust mite sublingual tablet]) and an increased probability of having a mild AR day (from 16% [placebo] to 34% [SQ house dust mite sublingual tablet]). © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  14. Ventilation in homes infested by house-dust mites.

    Science.gov (United States)

    Sundell, J; Wickman, M; Pershagen, G; Nordvall, S L

    1995-02-01

    Thirty single-family homes with either high (> or = 2000 ng/g) or low (< or = 1000 ng/g) house-dust mite (HDM) allergen levels in mattress dust were examined for ventilation, thermal climate, and air quality (formaldehyde and total volatile organic compounds (TVOC). Elevated concentrations of HDM allergen in mattress and floor dust were associated with the difference in absolute humidity between indoor and outdoor air, as well as with low air-change rates of the home, particularly the bedroom. No correlation was found between concentration of TVOC or formaldehyde in bedroom air and HDM allergen concentration. In regions with a cold winter climate, the air-change rate of the home and the infiltration of outdoor air into the bedroom appear to be important for the infestation of HDM.

  15. Occurrence of polybrominated diphenyl ethers in floor and elevated surface house dust from Shanghai, China.

    Science.gov (United States)

    Niu, Dong; Qiu, Yanling; Li, Li; Zhou, Yihui; Du, Xinyu; Zhu, Zhiliang; Chen, Ling; Lin, Zhifen

    2018-04-24

    House dust is the main source of human exposure to flame retardants by ingestion. This study investigated the occurrence of polybrominated diphenyl ethers (PBDEs) in indoor dust from 22 houses in Shanghai, China. House dust was separately collected from the floor and elevated furnishings surface (mostly between 0.5 and 2 m height) for comparison. The concentrations of ∑ 22 PBDEs ranged from 19.4 to 3280 ng/g (with a geometric mean of 203 ng/g) and from 55.1 to 792 ng/g (with a geometric mean of 166 ng/g) in floor dust (FD) and elevated surface dust (ESD), respectively. BDE-209 was the predominant congener, accounting for about 73.1% of total PBDE burdens. In terms of congener profiles, the comparison of FD and ESD revealed no significant differences except for the ratio of BDE-47/BDE-99. ESD samples displayed a ratio of BDE-47/BDE-99 very similar to commercial penta-BDE products DE-71 while the ratio in FD was exceptionally higher. Significant correlation was found between concentrations of commercial penta-BDE compositions in FD and ESD (p house dust exhibited temporal stability. Human exposure to PBDEs via dust ingestion was estimated. The highest daily intake of PBDEs was for toddlers by using 95th percentile concentrations of PBDEs via high dust ingestion in FD (23.07 ng/kg bw/day). About 20-fold difference in exposure estimates between toddlers and adults supports that toddlers are facing greater risk from indoor floor dust. Expectedly, this study highlighted the point that residents in Shanghai were exposed to low doses of PBDEs in house dust.

  16. The effects of a newsletter on bedding control on house dust mite allergen concentrations in childcare centers in Korea

    Directory of Open Access Journals (Sweden)

    Jeonghoon Kim

    2015-08-01

    Full Text Available Objectives Bedding in childcare centers (CCCs can hold house dust mite (HDM allergens. This study examined whether HDM allergen levels can be reduced through the distribution of an educational newsletter on bedding control to parents of CCC children in Korea. Methods All 38 CCCs were measured for Der 1 (sum of Der f 1 and Der p 1 concentrations on classroom floors and bedding before the intervention. Educational newsletters on children’s bedding control were sent to 21 CCCs by mail, and teachers were asked to distribute the newsletters to the parents of the children (intervention group. The remaining 17 CCCs were not sent newsletters (control group. The measurement of Der 1 concentrations in 38 CCCs was repeated after the intervention. Dust samples were collected with a vacuum cleaner and analyzed using enzyme-linked immunosorbent assay methods. Results The Der 1 concentrations on the bedding were significantly higher than those on the floors in 38 CCCs at baseline (p<0.05. Although changes of the Der 1 concentrations for the control group (n=17 were not significant, Der 1 concentrations for the intervention group (n=21 decreased significantly from 2077.9 ng/g dust to 963.5 ng/g dust on the floors and from 3683.9 ng/g dust to 610.4 ng/g dust on bedding (p<0.05. Conclusions The distribution of educational newsletters on bedding control to parents may be an effective means of controlling HDMs in CCCs.

  17. Associations between brominated flame retardants in house dust and hormone levels in men

    International Nuclear Information System (INIS)

    Johnson, Paula I.; Stapleton, Heather M.; Mukherjee, Bhramar; Hauser, Russ; Meeker, John D.

    2013-01-01

    Brominated flame retardants (BFRs) are used in the manufacture of a variety of materials and consumer products in order to meet fire safety standards. BFRs may persist in the environment and have been detected in wildlife, humans and indoor dust and air. Some BFRs have demonstrated endocrine and reproductive effects in animals, but human studies are limited. In this exploratory study, we measured serum hormone levels and flame retardant concentrations [31 polybrominated diphenyl ether (PBDE) congeners and 6 alternate flame retardants] in house dust from men recruited through a US infertility clinic. PBDE congeners in dust were grouped by commercial mixtures (i.e. penta-, octa- and deca-BDE). In multivariable linear regression models adjusted by age and body mass index (BMI), significant positive associations were found between house dust concentrations of pentaBDEs and serum levels of free T4, total T3, estradiol, and sex hormone binding globulin (SHBG), along with an inverse association with follicle stimulating hormone (FSH). There were also positive associations of octaBDE concentrations with serum free T4, thyroid stimulating hormone (TSH), luteinizing hormone (LH) and testosterone and an inverse association of decaBDE concentrations with testosterone. Hexabromocyclododecane (HBCD) was associated with decreased SHBG and increased free androgen index. Dust concentrations of bis-tribromophenoxyethane (BTBPE) and tetrabromo-diethylhexylphthalate (TBPH) were positively associated with total T3. These findings are consistent with our previous report of associations between PBDEs (BDE 47, 99 and 100) in house dust and hormone levels in men, and further suggest that exposure to contaminants in indoor dust may be leading to endocrine disruption in men. - Highlights: ► Brominated flame retardants (BFRs) including PBDEs and alternates were measured. ► Exposure to BFRs is characterized from concentrations in participant vacuum bag dust. ► Exposure to PBDEs and

  18. Associations between brominated flame retardants in house dust and hormone levels in men

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Paula I. [Department of Environmental Health Sciences, University of Michigan, 1415 Washington Heights, Ann Arbor, MI 48109 (United States); Stapleton, Heather M. [Nicholas School of the Environment, Box 90328, Duke University, Durham, NC 27708 (United States); Mukherjee, Bhramar [Department of Biostatistics, University of Michigan, 1415 Washington Heights, Ann Arbor, MI 48109 (United States); Hauser, Russ [Department of Environmental Health, Harvard School of Public Health, 677 Huntington Ave., Boston, MA 02115 (United States); Meeker, John D., E-mail: meekerj@umich.edu [Department of Environmental Health Sciences, University of Michigan, 1415 Washington Heights, Ann Arbor, MI 48109 (United States)

    2013-02-15

    Brominated flame retardants (BFRs) are used in the manufacture of a variety of materials and consumer products in order to meet fire safety standards. BFRs may persist in the environment and have been detected in wildlife, humans and indoor dust and air. Some BFRs have demonstrated endocrine and reproductive effects in animals, but human studies are limited. In this exploratory study, we measured serum hormone levels and flame retardant concentrations [31 polybrominated diphenyl ether (PBDE) congeners and 6 alternate flame retardants] in house dust from men recruited through a US infertility clinic. PBDE congeners in dust were grouped by commercial mixtures (i.e. penta-, octa- and deca-BDE). In multivariable linear regression models adjusted by age and body mass index (BMI), significant positive associations were found between house dust concentrations of pentaBDEs and serum levels of free T4, total T3, estradiol, and sex hormone binding globulin (SHBG), along with an inverse association with follicle stimulating hormone (FSH). There were also positive associations of octaBDE concentrations with serum free T4, thyroid stimulating hormone (TSH), luteinizing hormone (LH) and testosterone and an inverse association of decaBDE concentrations with testosterone. Hexabromocyclododecane (HBCD) was associated with decreased SHBG and increased free androgen index. Dust concentrations of bis-tribromophenoxyethane (BTBPE) and tetrabromo-diethylhexylphthalate (TBPH) were positively associated with total T3. These findings are consistent with our previous report of associations between PBDEs (BDE 47, 99 and 100) in house dust and hormone levels in men, and further suggest that exposure to contaminants in indoor dust may be leading to endocrine disruption in men. - Highlights: ► Brominated flame retardants (BFRs) including PBDEs and alternates were measured. ► Exposure to BFRs is characterized from concentrations in participant vacuum bag dust. ► Exposure to PBDEs and

  19. Organophosphate Flame Retardants in House Dust from South China and Related Human Exposure Risks.

    Science.gov (United States)

    Tan, Hongli; Peng, Changfeng; Guo, Ying; Wang, Xiaodong; Wu, Yan; Chen, Da

    2017-09-01

    House dust associated with organic pollutants is not only a potential source of pollutants to the outdoor environment, but also a source to human exposure. The present study investigated the occurrence and concentrations of organophosphate flame retardants (OPFRs) in house dust collected from South China dwellings (n = 20). The results revealed a universal presence of most target OPFRs in house dust, with concentrations of ΣOPFRs ranging from 2.06 to 19.95 μg/g. The median concentration of ΣOPFR (9.20 μg/g) was one order of magnitude greater than that of polybrominated diphenyl ethers (0.80 μg/g). The composition of OPFR chemicals in house dust was dominated by chlorinated OPFRs, such as tris(1,3-dichloro-2-propyl) phosphate (TDCPP) and tris(1-chloro-2-propyl) phosphate (TCPP). This compositional pattern was different from what has been reported in indoor dust from many other countries, where tris(2-butoxyethyl) phosphate (TBEP) was generally dominant. The daily intake of OPFRs by adults was estimated to be 1.6 and 4.2 ng/kg body weight/day under average and high exposure scenarios, respectively, and 31.7 and 127 ng/kg body weight/day for toddlers.

  20. Particle size distribution of brominated flame retardants in house dust from Japan

    Directory of Open Access Journals (Sweden)

    Natsuko Kajiwara

    2016-06-01

    Full Text Available The present study was conducted to examine the concentrations, profiles, and mass distributions of polybrominated diphenyl ethers (PBDEs, hexabromocyclododecanes (HBCDs, and polybrominated dibenzo-p-dioxins/furans (PBDD/Fs based on the particle sizes of house dust samples from five homes in Japan. After removal of impurities from house dust from vacuum cleaner bags, selected indoor dust samples were size fractionated (>2 mm, 1–2 mm, 0.5–1 mm, 250–500 μm, 106–250 μm, 53–106 μm, and 250 μm in size and fluffy dust were included. The conclusion is that particulate dust <250 μm in size without fluffy dust should be used to analyze dust for brominated flame retardants.

  1. House-dust mites in our homes are a contamination from outdoor sources.

    Science.gov (United States)

    Hallas, Thorkil E

    2010-05-01

    Avoidance advices for house-dust mite sensitized persons are currently based upon the idea, that the mites (Dermatophagoides spp.) are part of the indoor fauna. A closer look at development stages in the house-dust samples shows, however, that only the mites' active stages are present there and that the stages between them, the inactive moulting stages, are absent. Therefore the mites probably do not carry out their life cycles in our dwellings, but are more likely contaminations from the open. Findings of low level concentrations can be explained by mites coming from outdoors and sedimented in accordance with known physical laws. The occasional finding of higher concentrations is the result of synchronized populations of the mites developing outdoors and being passively transported into our homes by wind and dust. The hypothesis explains why we find mites in our homes but nonetheless have no effect of avoidance measures. The verification of the entire hypothesis or part of it may have great impact on the management of the disease house-dust mite allergy.

  2. House-dust mites in our homes are a contamination from outdoor sources

    DEFF Research Database (Denmark)

    Hallas, Thorkil E.

    2010-01-01

    there and that the stages between them, the inactive moulting stages, are absent. Therefore the mites probably do not carry out their life cycles in our dwellings, but are more likely contaminations from the open. Findings of low level concentrations can be explained by mites coming from outdoors and sedimented......Avoidance advices for house-dust mite sensitized persons are currently based upon the idea, that the mites (Dermatophagoides spp.) are part of the indoor fauna. A closer look at development stages in the house-dust samples shows, however, that only the mites' active stages are present...... no effect of avoidance measures. The verification of the entire hypothesis or part of it may have great impact on the management of the disease house-dust mite allergy....

  3. Determinants of manganese levels in house dust samples from the CHAMACOS cohort

    Energy Technology Data Exchange (ETDEWEB)

    Gunier, R.B., E-mail: gunier@berkeley.edu [Center for Environmental Research and Children’s Health (CERCH), School of Public Health, University of California, Berkeley, CA (United States); Jerrett, M. [Center for Environmental Research and Children’s Health (CERCH), School of Public Health, University of California, Berkeley, CA (United States); Smith, D.R.; Jursa, T. [Microbiology and Environmental Toxicology, University of California, Santa Cruz, CA (United States); Yousefi, P.; Camacho, J.; Hubbard, A.; Eskenazi, B.; Bradman, A. [Center for Environmental Research and Children’s Health (CERCH), School of Public Health, University of California, Berkeley, CA (United States)

    2014-11-01

    Introduction: Manganese (Mn) is an essential nutrient, but at high exposure levels Mn is a neurotoxicant. The fungicides maneb and mancozeb are approximately 21% Mn by weight and more than 150,000 kg are applied each year to crops in the Salinas Valley, California. It is not clear, however, whether agricultural use of these fungicides increases Mn levels in homes. Materials and methods: We collected house dust samples from 378 residences enrolled in the Center for the Health Assessment of Mothers and Children of Salinas (CHAMACOS) study with a second sample collected approximately nine months later from 90 of the residences. House dust samples were analyzed for Mn using inductively coupled plasma optical emission spectroscopy. Information from interviews, home inspections, and pesticide use reports was used to identify potential predictors of Mn dust concentrations and loadings. Results: Mn was detectable in all dust samples. The median Mn concentration was 171 μg/g and median Mn loading was 1,910 μg/m{sup 2} at first visit. In multivariable models, Mn dust concentrations and loadings increased with the number of farmworkers in the home and the amount of agricultural Mn fungicides applied within three kilometers of the residence during the month prior to dust sample collection. Dust concentrations of Mn and other metals (lead, cadmium and chromium) were higher in residences located in the southern Salinas Valley compared those located in other areas of the Salinas Valley. Dust loadings of Mn and other metals were also higher in residences located on Antioch Loam soil than other soil types, and in homes with poor or average housekeeping practices. Conclusions: Agricultural use of Mn containing fungicides was associated with Mn dust concentrations and loadings in nearby residences and farmworker homes. Housekeeping practices and soil type at residence were also important factors related to dust metal concentrations and loadings. - Highlights: • Manganese dust

  4. Investigating A Novel Flame Retardant Known as V6: Measurements in Baby Products, House Dust and Car Dust

    Science.gov (United States)

    Fang, Mingliang; Webster, Thomas F.; Gooden, David; Cooper, Ellen M.; McClean, Michael D.; Carignan, Courtney; Makey, Colleen; Stapleton, Heather M.

    2013-01-01

    With the phase-out of polybrominated diphenyl ether (PBDE) flame retardants, the use of new and alternate flame retardants has been increasing. 2,2-bis(chloromethyl)propane-1,3-diyltetrakis(2-chloroethyl) bisphosphate, known as V6, is a flame retardant applied to polyurethane foam commonly found in furniture and automobile foam. However, to the authors’ knowledge, no research has been conducted on V6 levels in the environment. The intention of this study was to measure the concentration of V6 in foam collected from baby products where it was recently detected, and measure levels in dust samples collected from homes and automobiles in the Boston, MA area. To accomplish this a pure V6 commercial standard was purchased from a Chinese manufacturer and purified (> 98%). An analytical method to measure V6 in dust samples using liquid chromatography tandem mass spectrometry (LC/MS-MS) was developed. Extraction was conducted using Accelerated Solvent Extraction (ASE) and extracts were purified using an ENVI-Florisil SPE column (500 mg, 3mL). V6 was measured in foam samples collected from baby products with a concentration ranging from 24,500,000 to 59,500,000 ng/g of foam (n = 12, average ± sd: 46,500,000 ± 12,000,000 ng/g; i.e., on average, 4.6 % of the foam mass was V6). V6 was also detected in 19 of 20 car dust samples and 14 of 20 house dust samples analyzed. The concentration of V6 in the house dust ranged from car dust with a median of 103.0 ng/g. Concentrations in car dust were significantly higher than the house dust, potentially indicating higher use of V6 in automobiles compared to products found in the home. Furthermore, tris (2-chloroethyl) phosphate (TCEP), a known carcinogen, was found in the V6 commercial mixture (14% by weight) as an impurity and was consistently detected with V6 in the foam samples analyzed. A significant correlation was also observed between V6 and TCEP in the dust samples, suggesting that the use of V6 is a significant source of TCEP

  5. House dust mite control measures for asthma

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C.; Johansen, Helle Krogh

    2008-01-01

    BACKGROUND: The major allergen in house dust comes from mites. Chemical, physical and combined methods of reducing mite allergen levels are intended to reduce asthma symptoms in people who are sensitive to house dust mites. OBJECTIVES: To assess the effects of reducing exposure to house dust mite...... antigens in the homes of people with mite-sensitive asthma. SEARCH STRATEGY: PubMed and The Cochrane Library (last searches Nov 2007), reference lists. SELECTION CRITERIA: Randomised trials of mite control measures vs placebo or no treatment in people with asthma known to be sensitive to house dust mites......), the standardised mean difference was 0.00 (95% confidence interval (CI) -0.10 to 0.10). There were no statistically significant differences either in number of patients improved (relative risk 1.01, 95% CI 0.80 to 1.27), asthma symptom scores (standardised mean difference -0.04, 95% CI -0.15 to 0...

  6. Investigating a novel flame retardant known as V6: measurements in baby products, house dust, and car dust.

    Science.gov (United States)

    Fang, Mingliang; Webster, Thomas F; Gooden, David; Cooper, Ellen M; McClean, Michael D; Carignan, Courtney; Makey, Colleen; Stapleton, Heather M

    2013-05-07

    With the phase-out of polybrominated diphenyl ether (PBDE) flame retardants, the use of new and alternate flame retardants has been increasing. 2,2-bis(chloromethyl)propane-1,3-diyltetrakis(2-chloroethyl) bisphosphate, known as V6, is a flame retardant applied to polyurethane foam commonly found in furniture and automobile foam. However, to the authors' knowledge, no research has been conducted on V6 levels in the environment. The intention of this study was to measure the concentration of V6 in foam collected from baby products where it was recently detected and measure levels in dust samples collected from homes and automobiles in the Boston, MA area. To accomplish this, a pure V6 commercial standard was purchased from a Chinese manufacturer and purified (>98%). An analytical method to measure V6 in dust samples using liquid chromatography tandem mass spectrometry (LC/MS-MS) was developed. Extraction was conducted using accelerated solvent extraction (ASE) and extracts were purified using an ENVI-Florisil SPE column (500 mg, 3 mL). V6 was measured in foam samples collected from baby products with a concentration ranging from 24,500,000 to 59,500,000 ng/g of foam (n = 12, average ± sd: 46,500,000 ± 12,000,000 ng/g; i.e., on average, 4.6% of the foam mass was V6). V6 was also detected in 19 of 20 car dust samples and 14 of 20 house dust samples analyzed. The concentration of V6 in the house dust ranged from <5 ng/g to 1110 ng/g with a median of 12.5 ng/g, and <5 ng/g to 6160 ng/g in the car dust with a median of 103.0 ng/g. Concentrations in car dust were significantly higher than in the house dust potentially indicating higher use of V6 in automobiles compared to products found in the home. Furthermore, tris (2-chloroethyl) phosphate (TCEP), a known carcinogen, was found in the V6 commercial mixture (14% by weight) as an impurity and was consistently detected with V6 in the foam samples analyzed. A significant correlation was also observed between V6 and TCEP in

  7. House dust as possible route of environmental exposure to cadmium and lead in the adult general population

    International Nuclear Information System (INIS)

    Hogervorst, Janneke; Plusquin, Michelle; Vangronsveld, Jaco; Nawrot, Tim; Cuypers, Ann; Van Hecke, Etienne; Roels, Harry A.; Carleer, Robert; Staessen, Jan A.

    2007-01-01

    Contaminated soil particles and food are established routes of exposure. We investigated the relations between biomarkers of exposure to cadmium and lead, and the metal loading rates in house dust in the adult residents of an area with a soil cadmium concentration of >=3mg/kg (n=268) and a reference area (n=205). We determined the metal concentrations in house dust allowed to settle for 3 months in Petri dishes placed in the participants' bedrooms. The continuously distributed vegetable index was the first principal component derived from the metal concentrations in six different vegetables. The biomarkers of exposure (blood cadmium 9.2 vs. 6.2nmol/L; 24-h urinary cadmium 10.5 vs. 7.0nmol; blood lead 0.31 vs. 0.24μmol/L), the loading rates of cadmium and lead in house dust (0.29 vs. 0.12 and 7.52 vs. 3.62ng/cm 2 /92 days), and the vegetable indexes (0.31 vs. -0.44 and 0.13 vs. -0.29 standardized units) were significantly higher in the contaminated area. A two-fold increase in the metal loading rate in house dust was associated with increases (P<0.001) in blood cadmium (+2.3%), 24-h urinary cadmium (+3.0%), and blood lead (+2.0%), independent of the vegetable index and other covariates. The estimated effect sizes on the biomarkers of internal exposure were three times greater for house dust than vegetables. In conclusion, in the adult population, house dust is potentially an important route of exposure to heavy metals in areas with contaminated soils, and should be incorporated in the assessment of health risks

  8. Use of Monte Carlo analysis in a risk-based prioritization of toxic constituents in house dust.

    Science.gov (United States)

    Ginsberg, Gary L; Belleggia, Giuliana

    2017-12-01

    Many chemicals have been detected in house dust with exposures to the general public and particularly young children of potential health concern. House dust is also an indicator of chemicals present in consumer products and the built environment that may constitute a health risk. The current analysis compiles a database of recent house dust concentrations from the United States and Canada, focusing upon semi-volatile constituents. Seven constituents from the phthalate and flame retardant categories were selected for risk-based screening and prioritization: diethylhexyl phthalate (DEHP), butyl benzyl phthalate (BBzP), diisononyl phthalate (DINP), a pentabrominated diphenyl ether congener (BDE-99), hexabromocyclododecane (HBCDD), tris(1,3-dichloro-2-propyl) phosphate (TDCIPP) and tris(2-chloroethyl) phosphate (TCEP). Monte Carlo analysis was used to represent the variability in house dust concentration as well as the uncertainty in the toxicology database in the estimation of children's exposure and risk. Constituents were prioritized based upon the percentage of the distribution of risk results for cancer and non-cancer endpoints that exceeded a hazard quotient (HQ) of 1. The greatest percent HQ exceedances were for DEHP (cancer and non-cancer), BDE-99 (non-cancer) and TDCIPP (cancer). Current uses and the potential for reducing levels of these constituents in house dust are discussed. Exposure and risk for other phthalates and flame retardants in house dust may increase if they are used to substitute for these prioritized constituents. Therefore, alternative assessment and green chemistry solutions are important elements in decreasing children's exposure to chemicals of concern in the indoor environment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Exposures Related to House Dust Microbiota in a U.S. Farming Population.

    Science.gov (United States)

    Lee, Mi Kyeong; Carnes, Megan U; Butz, Natasha; Azcarate-Peril, M Andrea; Richards, Marie; Umbach, David M; Thorne, Peter S; Beane Freeman, Laura E; Peddada, Shyamal D; London, Stephanie J

    2018-06-01

    Environmental factors can influence the house dust microbiota, which may impact health outcomes. Little is known about how farming exposures impact the indoor microbiota. We aimed to identify exposures related to bacterial communities in house dust in a U.S. farming population. We used 16S rRNA amplicon sequencing to characterize bacterial communities in vacuumed dust samples from the bedrooms of a subset of 879 households of farmers and farmers' spouses enrolled in the Agricultural Lung Health Study (ALHS), a case-control study of asthma nested within the Agricultural Health Study (AHS) in North Carolina and Iowa. Information on current farming (past 12 mo), including both crop and animal farming, and other potential microbial sources was obtained via questionnaires. We used linear regression to evaluate associations between exposures and bacterial diversity within each sample, analysis of similarity (ANOSIM), and permutational multivariate analysis of variance (PERMANOVA) to identify exposures related to diversity between samples, and analysis of composition of microbiome to examine whether exposures related to diversity were also related to differential abundance of specific operational taxonomic units (OTUs). Current farming was positively associated with bacterial diversity in house dust, with or without adjustment for nonfarm exposures related to diversity, including presence of indoor pets, home condition, and season of dust collection. Many taxa exhibited differential abundance related to farming. Some taxa in the phyla Chloroflexi and Verrucomicrobia were associated [false discovery rate (FDR)<0.05] with farming but not with other nonfarm factors. Many taxa correlated with the concentration of house dust of endotoxin, commonly studied as a general marker of exposure to the farming environment. In this farming population, house dust microbiota differed by current farming status. Understanding the determinants of the indoor microbiota is the first step

  10. House dust mites in the city of Lima, Peru.

    Science.gov (United States)

    Croce, M; Costa-Manso, E; Baggio, D; Croce, J

    2000-01-01

    Since mites are the most common house dust allergens, knowledge about the species most prevalent in a region is important for diagnostic and specific immunotherapy purposes. In order to establish the prevalence of house dust mites in different city districts, 100 house dust samples were collected from different parts of Lima. Lima is a city of tropical climate located along the coast of the Pacific Ocean. The relative air humidity is 80-90% and the various districts studied are located at altitudes ranging from 37-355 meters. The mite Blomia tropicalis was the organism most frequently detected, being present in 59% of the house dust samples. Dermatophagoides pteronyssinus occupied second place (15.9%), followed by Chortoglyphus arcuatus and Tyrophagus putrescentiae. These four mites, taken together, represented more than 90% of the mites detected. No specimen of the species Dermatophagoides farinae was detected. We conclude that B. tropicalis and D. pteronyssinus are the most common house dust mites in Lima. Considering the high prevalence of B. tropicalis in Lima and the fact that its cross-reactivity with antigens of the mites of the family Pyroglyphidae is minimal, we conclude that sensitization to this mite should be investigated separately in allergic patients living in Lima.

  11. House Dust Mite Respiratory Allergy

    DEFF Research Database (Denmark)

    Calderón, Moisés A; Kleine-Tebbe, Jörg; Linneberg, Allan

    2015-01-01

    Although house dust mite (HDM) allergy is a major cause of respiratory allergic disease, specific diagnosis and effective treatment both present unresolved challenges. Guidelines for the treatment of allergic rhinitis and asthma are well supported in the literature, but specific evidence on the e......Although house dust mite (HDM) allergy is a major cause of respiratory allergic disease, specific diagnosis and effective treatment both present unresolved challenges. Guidelines for the treatment of allergic rhinitis and asthma are well supported in the literature, but specific evidence...... not extend beyond the end of treatment. Finally, allergen immunotherapy has a poor but improving evidence base (notably on sublingual tablets) and its benefits last after treatment ends. This review identifies needs for deeper physician knowledge on the extent and impact of HDM allergy in respiratory disease...... and therapy of HDM respiratory allergy in practice....

  12. Exposure to phthalates in house dust and associated allergies in children aged 6-12years.

    Science.gov (United States)

    Ait Bamai, Yu; Araki, Atsuko; Kawai, Toshio; Tsuboi, Tazuru; Saito, Ikue; Yoshioka, Eiji; Cong, Shi; Kishi, Reiko

    2016-11-01

    Phthalates are widely used as plasticizers in household products. Several studies have reported an association between phthalate exposure and an increased risk of allergies. The present study estimated phthalate exposure in children aged 6-12years and assessed potential correlations with allergies. House dust samples were collected from floors and multi-surface objects >35cm above the floor. Urine samples were collected from the first morning void of the day. Daily phthalate intake (DI dust and DI) was estimated using both house dust and urinary metabolite concentrations. Exposure to di-2-ethylhexyl phthalate (DEHP) in floor dust was associated with parental-reported rhino-conjunctivitis. After stratification by gender, this trend was found to only occur in boys. Furthermore, urinary mono-isobutyl phthalate was inversely associated with parental-reported wheeze in boys. DI dust of benzyl butyl phthalate (BBzP) and DEHP were significantly correlated with DI_BBzP and DI_DEHP, respectively. These correlations were stronger with floor than with multi-surface dust. Our results suggest that, among Japanese children, house dust from low surfaces, such as living room floors, might play a meaningful role in the indoor environmental exposure pathway for BBzP and DEHP. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Measurement of the flame retardants polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCDD) in house dust

    Energy Technology Data Exchange (ETDEWEB)

    Stapleton, H.; Dodder, N.; Schantz, M.; Wise, S. [National Institute of Standards and Technology, Gaithersburg, MD (United States)

    2004-09-15

    Current monitoring of polybrominated diphenyl ethers (PBDEs) has shown that concentrations are increasing in the environment very rapidly with doubling times as short as three to five years. North America consumes a large percentage of the global market demand for PBDEs, and as a result, concentrations of PBDEs in human milk and serum are an order of magnitude higher in women from North America relative to Europe. Within sampled populations, PBDE levels in human serum have been shown to range over an order of magnitude, and high levels cannot always be attributed to occupational exposure, age or diet. One source that may be responsible for these observations is exposure in the home. These compounds are liberally applied to many common household items such as furniture, mattresses, computers and TVs to retard or hinder the outbreak of fire. Over time, these flame retardants may leach out into the home environment, where they may be inhaled or ingested, resulting in elevated levels in human serum. Very few studies have examined PBDE levels within the home and only one study has measured the concentrations of two PBDE congeners in house dust. The present study was undertaken to measure a suite PBDE congeners in house dust from a variety of homes and to assess the contribution of the three commercial PBDE mixtures (penta-, octa- and decaBDE) to the house dust composition. In addition, we also measured the concentrations of hexabromocyclododecane (HBCDD), another flame retardant. Correlations with properties of the houses such as year of construction, square footage, carpeting coverage and number of computers in the house were also examined for any positive influences.

  14. Sensitization of children in the Stockholm area to house dust mites.

    Science.gov (United States)

    Nordvall, S L; Eriksson, M; Rylander, E; Schwartz, B

    1988-09-01

    Atopic sensitization of children in the Stockholm area to house dust mites (HDM) was investigated in a case-control study. Sixty children with and 60 without positive skin prick tests for HDM were matched for age and sex. HDM-sensitized children had previously more often lived in other areas known to be mite infested than the control children. Sensitization to mites was related to dampness in the homes, but no significant relationship was found to the type of residence, frequent visits to a summer house in the archipelago or parental smoking. Dust samples from mattresses of the children with the strongest positive reactions to mites in skin prick tests and the respective controls were subjected to an enzyme immunoassay, to measure the content of the major allergens of the Dermatophagoides (D.) species D. pterinyssinus, D. farinae and D. microceras. Mattress dust samples from the beds of HDM-sensitized children contained significantly higher HDM antigen concentrations than those from the beds of controls. Private houses contained significantly more HDM antigens than flats and 10 of 11 homes in which a dampness problem was recognized contained mite antigens. It is postulated that mite infestation is increasing in the area, energy-saving measures creating improved conditions for HDM survival.

  15. Phthalates in dormitory and house dust of northern Chinese cities: Occurrence, human exposure, and risk assessment.

    Science.gov (United States)

    Li, Hai-Ling; Song, Wei-Wei; Zhang, Zi-Feng; Ma, Wan-Li; Gao, Chong-Jing; Li, Jia; Huo, Chun-Yan; Mohammed, Mohammed O A; Liu, Li-Yan; Kannan, Kurunthachalam; Li, Yi-Fan

    2016-09-15

    Phthalates are widely used chemicals in household products, which severely affect human health. However, there were limited studies emphasized on young adults' exposure to phthalates in dormitories. In this study, seven phthalates were extracted from indoor dust that collected in university dormitories in Harbin, Shenyang, and Baoding, in the north of China. Dust samples were also collected in houses in Harbin for comparison. The total concentrations of phthalates in dormitory dust in Harbin and Shenyang samples were significantly higher than those in Baoding samples. The total geometric mean concentration of phthalates in dormitory dust in Harbin was lower than in house dust. Di-(2-ethylhexyl) phthalate (DEHP) was the most abundant phthalate in both dormitory and house dust. The daily intakes of the total phthalates, carcinogenic risk (CR) of DEHP, hazard index (HI) of di-isobutyl phthalate (DiBP), dibutyl phthalate (DBP), and DEHP were estimated, the median values for all students in dormitories were lower than adults who live in the houses. Monte Carlo simulation was applied to predict the human exposure risk of phthalates. HI of DiBP, DBP, and DEHP was predicted according to the reference doses (RfD) provided by the United States Environmental Protection Agency (U.S.EPA) and the reference doses for anti-androgenicity (RfD AA) developed by Kortenkamp and Faust. The results indicated that the risks of some students had exceeded the limitation, however, the measured results were not exceeded the limitation. Risk quotients (RQ) of DEHP were predicted based on China specific No Significant Risk Level (NSRL) and Maximum Allowable Dose Level (MADL). The predicted results of CR and RQ of DEHP suggested that DEHP could pose a health risk through intake of indoor dust. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Exposure assessment of organophosphorus and organobromine flame retardants via indoor dust from elementary schools and domestic houses.

    Science.gov (United States)

    Mizouchi, Shigekazu; Ichiba, Masayoshi; Takigami, Hidetaka; Kajiwara, Natsuko; Takamuku, Toshiyuki; Miyajima, Toru; Kodama, Hiroki; Someya, Takashi; Ueno, Daisuke

    2015-03-01

    To assess the exposure of flame retardants (FRs) for school-children, organophosphorus flame retardants and plasticizers (PFRs) and organobromine flame retardants (BFRs) were determined in the indoor dust samples collected from elementary schools and domestic houses in Japan in 2009 and 2010. PFRs were detected in all the dust samples analyzed and the highest concentration of total PFRs was thousand-fold higher than that of BFRs. Among the PFRs, tris(butoxyethyl)phosphate (TBOEP) showed the highest concentration with a median (med.) of 270,000 ng g(-1) dry weight (3700-5,500,000 ng g(-1) dry weight), followed by tris(methylphenyl)phosphate (TMPPs)>triphenyl phosphate (TPHP)=tris(1,3-dichloro-2-propyl)phosphate (TDCIPP)=tris(2-chloroisopropyl)phosphate (TCIPP)=tris(2chloroethyl)phosphate (TCEP)>ethylhexyl diphenyl phosphate (EHDPP). Significantly higher concentrations of TBOEP, tri-n-butyl phosphate (TNBP), TPHP, TMPPs, and total-PFRs were found in dust samples from elementary schools than from domestic houses. It might be due to that higher concentrations of TBOEP (as leveling agent) were detected from the floor polisher/wax products collected in those elementary schools. On the other hand, significantly higher concentrations of TCEP, TCIPPs, and total chloroalkyl-PFRs were found in domestic houses than in elementary schools. Exposure assessments of PFRs via indoor dust from elementary schools and domestic houses were conducted by calculating the hazard quotient (HQ). Among PFRs, HQs for TBOEP exceeded 1 (higher than reference dose: RfD) and its highest value was 1.9. To reduce the intake of TBOEP by school-children, it is recommended that the use of floor polisher/wax containing TBOEP be reduced in schools. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Lead and other elements in house dust of Japanese residences – Source of lead and health risks due to metal exposure

    International Nuclear Information System (INIS)

    Yoshinaga, Jun; Yamasaki, Kumiko; Yonemura, Ayumi; Ishibashi, Yuri; Kaido, Takaya; Mizuno, Kodai; Takagi, Mai; Tanaka, Atsushi

    2014-01-01

    The levels of 25 elements in house dust collected from 100 general Japanese residences were measured. Factor analysis was applied on the multi-element data to explore source of Pb (median concentration 49.1 mg/kg) in house dust. Six factors were extracted and Pb was found to have great loading on the fifth factor with Sb and Sn, suggesting solder (Sn), and plastic and metals (Sb) may be the sources of Pb in the house dust of Japanese residences. No significant loading was found on soil-related factors indicating non-significant contribution of Pb in track-in soil. Seven heavy metals (Cd, Cu, Mo, Pb, Sb, Sn, and Zn) were found in house dust at >10 times more condensed than crustal abundance. Health risk of these elements to children via the ingestion of house dust was estimated based on the comparison with tolerable daily intake and found to be non-significant for most of the elements. - Highlights: • Multi-element analysis was carried out for house dust from households in Japan. • Factor analysis was applied on the multivariate data set. • The abundance of lead had a close relationship with antimony and tin in house dust. • Health risk of heavy metals in house dust for children was not serious. - Major source of Pb in house dust of Japanese residences was not track-in soil but unknown materials that contain Pb and Sb and/or Sn

  18. Garden soil and house dust as exposure media for lead uptake in the mining village of Stratoni, Greece.

    Science.gov (United States)

    Argyraki, Ariadne

    2014-08-01

    The relationships between two exposure media, garden soil and house dust, were studied for Pb uptake in Stratoni village in northern Greece, an industrial area of mining and processing of sulphide ore. Lead data for the two media were assessed in terms of total and bioaccessible content, measurement and geochemical variability, and mineralogical composition. It was found that total Pb was enriched in house dust samples by a factor of 2 on average. Total Pb concentration in soil samples had a maximum of 2,040 mg/kg and reached a maximum of 7,000 mg/kg in house dust samples. The estimated variability due to measurement uncertainty was dominated by the sampling process, and the proportion of sampling variance was greater for soil samples, indicating a higher degree of Pb heterogeneity in soil on the given spatial scale of sampling strata. Although the same general spatial trend was observed for both sampling media with decreasing Pb concentration by increasing distance from the ore-processing plant, Pb in dust samples displayed the highest concentrations within a 300-600-m zone from the ore-processing facility. The significant differences which were observed in Pb speciation between the studied media were explained by differences in mineralogical composition of outdoor soil and indoor dust. Lead-enriched Fe and Mn oxides predominated in soil samples while fine galena grains (<10-20 μm diameter) were the major Pb-bearing phase in dust samples. The integrated exposure uptake biokinetic model was used to predict the risk of elevated blood lead levels in children of Stratoni. Model prediction indicated an average probability of 61 % for blood-Pb to exceed 10 μg/dl. The results underline the importance of house dust in risk assessment and highlight the effect of outdoor and indoor conditions on the fate of Pb in the particular environment of Stratoni.

  19. Levels of house dust mite allergen in cars.

    Science.gov (United States)

    Mason, Howard J; Smith, Ian; Anua, Siti Marwanis; Tagiyeva, Nargiz; Semple, Sean; Devereux, Graham

    2015-09-01

    This small study investigated house dust mite (HDM) allergen levels in cars and their owners' homes in north-east Scotland. Dust samples from twelve households and cars were collected in a standardised manner. The dust samples were extracted and measured for the Dermatophagoides group 2 allergens (Der p 2 and Der f 2) and total soluble protein. Allergen levels at homes tended to be higher than in the cars, but not significantly. However, they significantly correlated with paired car dust samples expressed either per unit weight of dust or soluble protein (rho=0.657; p=0.02 and 0.769; p=0.003, respectively). This points to house-to-car allergen transfer, with the car allergen levels largely reflecting levels in the owner's home. Car HDM allergen levels were lower than those reported in Brazil and the USA. Twenty-five percent of the houses and none of the cars had allergen levels in dust greater than 2000 ng g(-1). This value is often quoted as a threshold for the risk of sensitisation, although a number of studies report increased risk of sensitisation at lower levels. This small study does not allow for characterisation of the distribution of HDM allergen in vehicles in this geographic area, or of the likely levels in other warmer and more humid areas of the UK. Cars and other vehicles are an under-investigated micro-environment for exposure to allergenic material.

  20. Relevancy of human exposure via house dust to the contaminants lead and asbestos

    NARCIS (Netherlands)

    Oomen AG; Lijzen JPA; SIR; LER

    2004-01-01

    The present report addresses the issues whether house dust is likely to contribute substantially to the exposure of humans, in particular for the contaminants lead and asbestos. House dust consists for 30-70% of soil material, indicating that contaminated soil can lead to contaminated house dust. It

  1. Measurement of nicotine in household dust

    International Nuclear Information System (INIS)

    Kim, Sungroul; Aung, Ther; Berkeley, Emily; Diette, Gregory B.; Breysse, Patrick N.

    2008-01-01

    An analytical method of measuring nicotine in house dust was optimized and associations among three secondhand smoking exposure markers were evaluated, i.e., nicotine concentrations of both house dust and indoor air, and the self-reported number of cigarettes smoked daily in a household. We obtained seven house dust samples from self-reported nonsmoking homes and 30 samples from smoking homes along with the information on indoor air nicotine concentrations and the number of cigarettes smoked daily from an asthma cohort study conducted by the Johns Hopkins Center for Childhood Asthma in the Urban Environment. House dust nicotine was analyzed by isotope dilution gas chromatography-mass spectrometry (GC/MS). Using our optimized method, the median concentration of nicotine in the dust of self-reported nonsmoking homes was 11.7 ng/mg while that of smoking homes was 43.4 ng/mg. We found a substantially positive association (r=0.67, P<0.0001) between house dust nicotine concentrations and the numbers of cigarettes smoked daily. Optimized analytical methods showed a feasibility to detect nicotine in house dust. Our results indicated that the measurement of nicotine in house dust can be used potentially as a marker of longer term SHS exposure

  2. Protective effect of the DNA vaccine encoding the major house dust mite allergens on allergic inflammation in the murine model of house dust mite allergy

    Directory of Open Access Journals (Sweden)

    Lee Jaechun

    2006-02-01

    Full Text Available Abstract Background Vaccination with naked DNA encoding antigen induces cellular and humoral immunity characterized by the activation of specific Th1 cells. Objective To evaluate the effects of vaccination with mixed naked DNA plasmids encoding Der p 1, Der p 2, Der p 3, Der f 1, Der f 2, and Der f 3, the major house dust mite allergens on the allergic inflammation to the whole house dust mites (HDM crude extract. Methods Three hundred micrograms of these gene mixtures were injected into muscle of BALB/c mice. Control mice were injected with the pcDNA 3.1 blank vector. After 3 weeks, the mice were actively sensitized and inhaled with the whole house dust mite extract intranasally. Results The vaccinated mice showed a significantly decreased synthesis of total and HDM-specific IgE compared with controls. Analysis of the cytokine profile of lymphocytes after challenge with HDM crude extract revealed that mRNA expression of interferon-γ was higher in the vaccinated mice than in the controls. Reduced infiltration of inflammatory cells and the prominent infiltration of CD8+ T cells were observed in histology of lung tissue from the vaccinated mice. Conclusion Vaccination with DNA encoding the major house dust mite allergens provides a promising approach for treating allergic responses to whole house dust mite allergens.

  3. Elemental composition of airborne dust in the Shale Shaker House during an offshore drilling operation.

    Science.gov (United States)

    Hansen, A B; Larsen, E; Hansen, L V; Lyngsaae, M; Kunze, H

    1991-12-01

    During 2 days of an offshore drilling operation in the North Sea, 16 airborne dust samples from the atmosphere of the Shale Shaker House were collected onto filters. During this operation, drilling mud composed of a water slurry of barite (BaSO4) together with minor amounts of additives, among them chrome lignosulphonate and chrome lignite, was circulated between the borehole and the Shale Shaker House. The concentration of airborne dust in the atmosphere was determined and the elemental composition of the particles analysed by both PIXE (proton-induced X-ray emission) and ICP-MS (inductively coupled plasma-mass spectrometry). The total amount of dust collected varied from 0.04 to 1.41 mg m-3 with barium (Ba) as the single most abundant element. The open shale shakers turned out to be the major cause of generation of dust from the solid components of the drilling mud.

  4. Contribution from indoor sources to particle number and mass concentrations in residential houses

    Science.gov (United States)

    He, Congrong; Morawska, Lidia; Hitchins, Jane; Gilbert, Dale

    As part of a large study investigating indoor air in residential houses in Brisbane, Australia, the purpose of this work was to quantify emission characteristics of indoor particle sources in 15 houses. Submicrometer particle number and approximation of PM 2.5 concentrations were measured simultaneously for more than 48 h in the kitchen of all the houses by using a condensation particle counter (CPC) and a photometer (DustTrak), respectively. In addition, characterizations of particles resulting from cooking conducted in an identical way in all the houses were measured by using a scanning mobility particle sizer (SMPS), an aerodynamic particle sizer (APS) and a DustTrak. All the events of elevated particle concentrations were linked to indoor activities using house occupants diary entries, and catalogued into 21 different types of indoor activities. This enabled quantification of the effect of indoor sources on indoor particle concentrations as well as quantification of emission rates from the sources. For example, the study found that frying, grilling, stove use, toasting, cooking pizza, cooking, candle vaporizing eucalyptus oil and fan heater use, could elevate the indoor submicrometer particle number concentration levels by more than five times, while PM 2.5 concentrations could be up to 3, 30 and 90 times higher than the background levels during smoking, frying and grilling, respectively.

  5. Application of synchrotron microprobe methods to solid-phase speciation of metals and metalloids in house dust.

    Science.gov (United States)

    Walker, S R; Jamieson, H E; Rasmussen, P E

    2011-10-01

    Determination of the source and form of metals in house dust is important to those working to understand human and particularly childhood exposure to metals in residential environments. We report the development of a synchrotron microprobe technique for characterization of multiple metal hosts in house dust. We have applied X-ray fluorescence for chemical characterization and X-ray diffraction for crystal structure identification using microfocused synchrotron X-rays at a less than 10 μm spot size. The technique has been evaluated by application to archived house dust samples containing elevated concentrations of Pb, Zn, and Ba in bedroom dust, and Pb and As in living room dust. The technique was also applied to a sample of soil from the corresponding garden to identify linkages between indoor and outdoor sources of metals. Paint pigments including white lead (hydrocerussite) and lithopone (wurtzite and barite) are the primary source of Pb, Zn, and Ba in bedroom dust, probably related to renovation activity in the home at the time of sampling. The much lower Pb content in the living room dust shows a relationship to the exterior soil and no specific evidence of Pb and Zn from the bedroom paint pigments. The technique was also successful at confirming the presence of chromated copper arsenate treated wood as a source of As in the living room dust. The results of the study have confirmed the utility of this approach in identifying specific metal forms within the dust.

  6. Mite fauna and fungal flora in house dust from homes of asthmatic children.

    Science.gov (United States)

    Ishii, A; Takaoka, M; Ichinoe, M; Kabasawa, Y; Ouchi, T

    1979-12-01

    Mite fauna and fungal flora in the house dust from homes of asthmatic children with positive and negative skin test to house dust allergen and non-asthmatic controls were examined. There was no conspicuous difference in mite species distribution among the three groups. Pyroglyphid mites dominate the mite fauna in house dust more than half of which being Dermatophagoides: D. pteronyssinus and D. farinae. There was no statistically significant difference in numbers between the two species and either species could dominate depending on the conditions of the individual houses. The average number of acarina in 0.5 g of fine dust did not differ statistically among the three groups; however, mite number per square meter floor differed between patients with positive skin test and negative skin test. The results suggest that house-cleaning might influence the possible sensitization of children. The genetic distribution of mould fungi in house dust was largely similar to that of airborne fungi. The average number of fungal colonies detected in 0.5 g of dust did not differ statistically among the three groups. Wallemia with its minute spores may cause sensitization but has so far been insufficiently investigated.

  7. Life cycle and reproduction of house-dust mites: environmental factors influencing mite populations.

    Science.gov (United States)

    Hart, B J

    1998-01-01

    An understanding of the life cycle of house-dust mites, as well as environmental factors influencing mite populations, can be exploited in mite control. The most important limiting factor for house-dust-mite populations is air humidity. House-dust mites osmoregulate through the cuticle and therefore require a high ambient air humidity to prevent excessive water loss. In addition, the supracoxal glands actively take up ambient water vapour, and the protonynph stage of the life cycle is resistant to desiccation. Larger house-dust-mite populations are found when the absolute indoor air humidity is above 7 g/kg (45% relative humidity at 20 degrees C). Consequently, ventilation by air-conditioning systems is being developed as a means of control. A number of other aspects of the domestic environment are also being manipulated in an integrated approach to render the habitat less suitable for mites. The potential exists for developing models for house-dust mite populations, environmental characteristics, and the effects of various approaches to control.

  8. Bioaccessibility of Fipronil Sorbed to Soil and House Dust

    Science.gov (United States)

    Fipronil is a phenylpyrazole insecticide with uses ranging from soil treatment, to the control of household pests and ectoparasites on pets. Soils and house dusts readily sorb fipronil and when these soils and dusts are ingested, the fipronil may become bioaccessible for uptake ...

  9. Comparative efficacy of house dust mite extermination products.

    Science.gov (United States)

    Schober, G; Kniest, F M; Kort, H S; De Saint Georges Gridelet, D M; Van Bronswijk, J E

    1992-06-01

    The acaricidal efficacy of nine marketed products, i.e. Acardust, Acarosan (foam and powder), Actelic 50, Artilin 3A (spirit and water base), liquid nitrogen, Paragerm AK, and Tymasil, and of intensive vacuum-cleaning have been compared on four different test surfaces: mattress, tufted carpet, gypsum board and rough wooden board, all covered with artificial house dust. They were inoculated with the house dust mite, Dermatophagoides pteronyssinus or the house-dust fungus Aspergillus repens for evaluation of the fungistatic claims of some products. The acaricidal activity of Tymasil did not surpass that of vacuuming; its fungistatic effect was not apparent. The other products showed complete to almost complete eradication on at least one of the substrates tested. Taking into account the results of acaricidal efficacy as well as the data on safety and practicality acquired earlier, Acarosan powder was considered first choice for carpet treatment. Acarosan and liquid nitrogen, were found to be effective in the treatment of mattress, pillow, upholstered furniture and heavy curtains. On wooden surfaces Acarosan was found to be both effective and safe, while Acardust, Actelic 50, Artilin 3A (both fungistatic as well as acaricidal), liquid nitrogen and Paragerm also passed the efficiency test.

  10. Child car seats – a habitat for house dust mites and reservoir for harmful allergens

    Directory of Open Access Journals (Sweden)

    David Clarke

    2015-02-01

    Full Text Available [b]Introduction and objective[/b]. House dust mites produce allergens which can cause or aggravate diseases such as asthma, eczema and rhinitis. The objectives of this study are to quantify typical house dust mite and Der p 1 allergen levels in child car seats, and to determine external variables that may influence mite populations in cars. [b]Materials and Methods[/b]. Dust samples were collected from the child car seats and driver seats of 106 cars using a portable vacuum sampling pump over a two minute sampling period. Mites were counted and identified and results were expressed as mites per gram (mites/g of dust, while Der p 1 content of samples were measured by enzyme-linked immunosorbent assay (ELISA. Questionnaires were completed by participants to identify environmental and behavioural effects on mite populations. Results were analysed using General Linear Model (GLM procedures. [b]Results[/b]. Twelve species of mites, of which nine are known to produce harmful allergens, were recorded from 212 dust samples. Over 80% of drivers’ seats and over 77% of child car seats harboured dust mites with a significant correlation (p = 0.001 between the mites/g of dust and Der p 1 content recovered from each seat. A mean of 53 mites/g of dust per seat was recovered, with a mean Der p 1 level of 1.1µg/g. Over 12% of driver seats and 15% of child car seats contained house dust mite levels sufficient to be risk factors for sensitisation and allergic reactions. [b]Conclusions[/b]. Child car seats and driver seats are habitats to a range of mite species which can be present in sufficient concentrations to cause or aggravate allergen related illnesses in individuals who are genetically predisposed.

  11. Human exposure to per- and polyfluoroalkyl substances (PFASs) via house dust in Korea: Implication to exposure pathway.

    Science.gov (United States)

    Tian, Zhexi; Kim, Seung-Kyu; Shoeib, Mahiba; Oh, Jeong-Eun; Park, Jong-Eun

    2016-05-15

    A wide range of per- and polyfluoroalkyl substances (PFASs), including fluorotelomer alcohols (FTOHs), perfluorooctane sulfonamidoethanols (FOSEs), perfluoroalkyl carboxylic acids (PFCAs), and perfluoroalkane sulfonic acids (PFSAs), were measured in fifteen house dust and two nonresidential indoor dust of Korea. Total concentrations of PFASs in house dust ranged from 29.9 to 97.6 ng g(-1), with a dominance of perfluorooctane sulfonic acid (PFOS), followed by 8:2 FTOH, N-Ethyl perfluorooctane sulfonamidoethanol (EtFOSE), perfluoroctanoic acid (PFOA). In a typical exposure scenario, the estimated daily intakes (EDIs) of total PFASs via house dust ingestion were 2.83 ng d(-1) for toddlers and 1.13 ng d(-1) for adults, which were within the range of the mean EDIs reported from several countries. For PFOA and PFOS exposure via house dust ingestion, indirect exposure (via precursors) was a minor contributor, accounting for 5% and 12%, respectively. An aggregated exposure (hereafter, overall-EDIs) of PFOA and PFOS occurring via all pathways, estimated using data compiled from the literature, were 53.6 and 14.8 ng d(-1) for toddlers, and 20.5 and 40.6 ng d(-1) for adults, respectively, in a typical scenario. These overall-EDIs corresponded to 82% (PFOA) and 92% (PFOS) of a pharmacokinetic model-based EDIs estimated from adults' serum data. Direct dietary exposure was a major contributor (>89% of overall-EDI) to PFOS in both toddlers and adults, and PFOA in toddlers. As for PFOA exposure of adults, however direct exposure via tap water drinking (37%) and indirect exposure via inhalation (22%) were as important as direct dietary exposure (41%). House dust-ingested exposure (direct+indirect) was responsible for 5% (PFOS in toddlers) and house-dust ingestion was a minor contributor in this study, but should not be ignored for toddlers' PFOS exposure due to its significance in the worst-case scenario. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Group 1 and 2 Dermatophagoides house dust mite allergens in the microenvironment of cats.

    Science.gov (United States)

    Loft, Klaus Earl; Rosser, Edmund J

    2010-04-01

    House dust mite allergens (HDMAs) are some of the most common allergens associated with allergic diseases in humans and dogs. The purpose of this study was to determine whether HDMAs could be detected in cat-associated household microenvironments. From 50 cat-only households with 95 cats, dust samples were collected by vacuuming for 2 min m(-2) from three areas where cats slept or rested regularly from September to October 2006. Relative humidity and temperature were measured in each household using a data logger. Each owner completed a questionnaire on potential factors that might influence the prevalence of house dust mites (HDMs). Dust samples were analysed utilizing an ELISA for Der p 1, Der f 1 and HDM group 2 allergens. In 38 of 50 households there was greater than 2 microg g(-1) of dust for at least one HDMA. Using stepwise logistic regression, factors associated with increased HDMA levels included: free-standing houses, number of humans in household, longhaired cats and age of the cat. Factors associated with decreased HDMA concentrations included: forced air heating and central air conditioning, less than 50% carpeting of the home, use of flea control, cats suffering from dermatological disease and the average temperature of the household. Many sleeping/resting areas utilized by cats contain sufficiently high levels of HDMAs to be potential sources of sensitization. This finding should lead to further determination of the role of HDMs in cats suffering from putative allergic conditions such as atopic dermatitis or asthma.

  13. Elemental composition of airborne dust in the shale shaker house during an offshore drilling operation

    DEFF Research Database (Denmark)

    Hansen, A.B.; Larsen, E.; Hansen, L.V.

    1991-01-01

    chrome lignosulphonate and chrome lignite, was circulated between the borehole and the Shale Shaker House. The concentration of airborne dust in the atmosphere was determined and the elemental composition of the particles analysed by both PIXE (proton-induced X-ray emission) and ICP-MS (inductively...

  14. Tetrabromobisphenol A in Indoor Dust from Houses and Internet Cafes

    Directory of Open Access Journals (Sweden)

    Ma. Pythias B. Espino

    2011-12-01

    Full Text Available Tetrabromobisphenol A or TBBPA is a widely used brominated flame retardant in modern materials such as electronic products, plastics and building materials. TBBPA can leach out of flame retardant-treated products during production, use, reuse, and final disposal of these consumer products. It has thus become a contemporary environmental contaminant. This study reports the levels of TBBPA in indoor dust from houses (n=4 and internet cafes (n=5 in Angono and Quezon City, in the Philippines. TBBPA in indoor dust was analyzed by ultrasonication-assisted hexane extraction and HPLC-UV determination. The instrument and method detection limits were 0.004 ng uL-1 and 1275 ng g-1, respectively. The standard calibration solutions ranged from 0.03 to 0.30 ng uL-1 (r2=0.9956. The extraction recovery was 78% (n=3. TBBPA was found in six of the nine indoor dust samples studied where the concentrations ranged from not detected to 4916 ng g-1. The occurrence and levels of TBBPA in indoor dusts are significant and suggest the need for further investigations especially in other microenvironments where people may be exposed to this contaminant.

  15. Endotoxin and dust at respirable and nonrespirable particle sizes are not consistent between cage- and floor-housed poultry operations.

    Science.gov (United States)

    Kirychuk, Shelley P; Reynolds, Stephen J; Koehncke, Niels K; Lawson, Joshua; Willson, Philip; Senthilselvan, Ambikaipakan; Marciniuk, Darcy; Classen, Henry L; Crowe, Trever; Just, Natasha; Schneberger, David; Dosman, James A

    2010-10-01

    Individuals engaged in work in intensive animal houses experience some of the highest rates of occupationally related respiratory symptoms. Organic dust and in particular endotoxin has been most closely associated with respiratory symptoms and lung function changes in workers. It has previously been shown that for intensive poultry operations, type of poultry housing [cage-housed (CH) versus floor-housed (FH)] can influence the levels of environmental contaminants. The goal of the study was to determine the differences in endotoxin and dust levels at different size fractions between CH and FH poultry operations. Fifteen CH and 15 FH poultry operations were sampled for stationary measurements (area) of dust and associated endotoxin. Fractioned samples were collected utilizing Marple cascade impactors. Gravimetric and endotoxin analysis were conducted on each of the filters. When assessed by individual Marple stage, there was significantly greater airborne endotoxin concentration (endotoxin units per cubic meter) in the size fraction >9.8 μm for the FH operations whereas at the size fraction 1.6-3.5 μm, the CH operations had significantly greater airborne endotoxin concentration than the FH operations. Endotoxin concentration in the dust mass (endotoxin units per milligram) was significantly greater in the CH operations as compared to the FH operations for all size fractions >1.6 μm. As such, endotoxin in the respirable fraction accounted for 24% of the total endotoxin in the CH operations whereas it accounted for only 11% in the FH operations. There was significantly more dust in all size fractions in the FH operations as compared to the CH poultry operations. There is more endotoxin in the presence of significantly lower dust levels in the respirable particle size fractions in CH poultry operations as compared to the FH poultry operations. This difference in respirable endotoxin may be important in relation to the differential respiratory response experienced by

  16. Determinants of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in house dust samples from four areas of the United States

    NARCIS (Netherlands)

    Deziel, N.C.; Nuckols, J.R.; Colt, J.S.; Roos, A.J. de; Pronk, A.; Gourley, C.; Severson, R.K.; Cozen, W.; Cerhan, J.R.; Hartge, P.; Ward, M.H.

    2012-01-01

    Determinants of levels of polychlorinated dibenzo- p-dioxins and polychlorinated dibenzofurans (PCDD/F) in dust in U.S. homes are not well characterized. We conducted a pilot study to evaluate the relationship between concentrations of PCDD/F in house dust and residential proximity to known sources,

  17. Per- and polyfluorinated compounds (PFCs) in house dust and indoor air in Catalonia, Spain: implications for human exposure.

    Science.gov (United States)

    Ericson Jogsten, I; Nadal, M; van Bavel, B; Lindström, G; Domingo, J L

    2012-02-01

    A total of 27 per- and polyfluorinated compounds (PFCs) were determined in both house dust (n=10) and indoor air (n=10) from selected homes in Catalonia, Spain. Concentrations were found to be similar or lower than those previously reported for household microenvironments in other countries. Ten PFCs were detected in all house dust samples. The highest mean concentrations corresponded to perfluorodecanoic acid (PFDA) and perfluorononanoic acid (PFNA), 10.7 ng/g (median: 1.5 ng/g) and 10.4 ng/g (median: 5.4 ng/g), respectively, while the 8:2 fluorotelomer alcohol (FTOH) was the dominating neutral PFC at a concentration of 0.41 ng/g (median: 0.35 ng/g). The indoor air was dominated by the FTOHs, especially the 8:2 FTOH at a mean (median) concentration of 51 pg/m(3) (median: 42 pg/m(3)). A limited number of ionic PFCs were also detected in the indoor air samples. Daily intakes of PFCs were estimated for average and worst case scenarios of human exposure from indoor sources. For toddlers, this resulted in average intakes of ∑ionic PFCs of 4.9ng/day (0.33 ng/kg(bw)/day for a 15 kg toddlers) and ∑neutral PFCs of 0.072 ng/day (0.005 ng/kg(bw)/day) from house dust. For adults, the average daily intakes of dust were 3.6 and 0.053 ng/day (0.05 and 0.001 ng/kg(bw)/day for a 70 kg adult) for ∑ionic and ∑neutral PFCs, respectively. The average daily inhalation of ∑neutral PFCs was estimated to be 0.9 and 1.3 ng/day (0.06 and 0.02 ng/kg(bw)/day) for toddlers and adults, respectively. For PFOS, the main ionic PFC detected in indoor air samples, the median intakes (based on those samples where PFOS was detected), resulted in indoor exposures of 0.06 and 0.11 ng/day (0.004 and 0.002 ng/kg(bw)/day) for toddlers and adults, respectively. Based on previous studies on dietary intake and drinking water consumption, both house dust and indoor air contribute significantly less to PFC exposure within this population. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Respiratory allergy caused by house dust mites

    DEFF Research Database (Denmark)

    Calderón, Moisés A; Linneberg, Allan; Kleine-Tebbe, Jörg

    2015-01-01

    consequences in patients with respiratory allergic diseases. We investigate the epidemiology of HDM allergy to explore the interaction between mites and human subjects at the population, individual, and molecular levels. Core and recent publications were identified by using "house dust mite" as a key search...

  19. Characterization of high concentration dust generator

    International Nuclear Information System (INIS)

    Shimura, Toichiro; Yokochi, Akira

    1999-01-01

    This paper describes the development of fluidized bed type high concentration dust generator that keeps for long period dust concentration range of about 10 mg/m 3 for the study of working place monitoring system and evaluation of respirator. The generator is keeping constant powder in fluidized bed for keeping the dust concentration. It is necessary to keep constant feeding rate of powder in order to keep the quantity of dust in the fluidized bed. Our generator enables to obtain constant feeding rate by a screw feeder and by using mixed powder with fluidising particles (glass beads) before feeding. The generator produces high concentration dust of 11.3 mg/m 3 ± 1.0 mg/m 3 for about 5 hours and keeps the dust size 4.2-4.6 μm in mass median aerodynamic diameter with reasonable reproducibility. (author)

  20. Prevailing indoor climate classification to predict house-dust mite abundance in Dutch homes

    NARCIS (Netherlands)

    Schober, G.; Verstappen, I.; Snijders, M.C.L.; Bronswijk, van J.E.M.H.

    1995-01-01

    In Europe 10-15 % of the human population is sensitized to allergens of house dust mites (Pyroglyphidae). Population development of house dust mites is primarily influenced by water activity (aw) of the mite habitat. The availability of H20 (water-activity and relative humidity) in the niches of

  1. Air Quality in Alternative Housing Systems May Have an Impact on Laying Hen Welfare. Part I—Dust

    Directory of Open Access Journals (Sweden)

    Bruce David

    2015-07-01

    Full Text Available The new legislation for laying hens in the European Union put a ban on conventional cages. Production systems must now provide the hens with access to a nest, a perch, and material for dust bathing. These requirements will improve the behavioral aspects of animal welfare. However, when hens are kept with access to litter, it is a concern that polluted air may become an increased threat to health and therefore also a welfare problem. This article reviews the literature regarding the health and welfare effects birds experience when exposed to barn dust. Dust is composed of inorganic and organic compounds, from the birds themselves as well as from feed, litter, and building materials. Dust may be a vector for microorganisms and toxins. In general, studies indicate that housing systems where laying hens have access to litter as aviaries and floor systems consistently have higher concentrations of suspended dust than caged hens with little (furnished cages or no access to litter (conventional cages. The higher dust levels in aviaries and floor housing are also caused by increased bird activity in the non-cage systems. There are gaps in both the basic and applied knowledge of how birds react to dust and aerosol contaminants, i.e., what levels they find aversive and/or impair health. Nevertheless, high dust levels may compromise the health and welfare of both birds and their caretakers and the poor air quality often found in new poultry housing systems needs to be addressed. It is necessary to develop prophylactic measures and to refine the production systems in order to achieve the full welfare benefits of the cage ban.

  2. The SQ House Dust Mite SLIT-Tablet Is Well Tolerated in Patients with House Dust Mite Respiratory Allergic Disease

    DEFF Research Database (Denmark)

    Emminger, Waltraud; Hernández, María Dolores; Cardona, Victòria

    2017-01-01

    BACKGROUND: The SQ house dust mite (HDM) SLIT-tablet (ALK, Denmark) addresses the underlying cause of HDM respiratory allergic disease, and a clinical effect has been demonstrated for both HDM allergic rhinitis and allergic asthma. Here, we present pooled safety data from an adult population with...

  3. The distribution of dust mite allergen in the houses of patients with asthma

    International Nuclear Information System (INIS)

    Tovey, E.R.; Chapman, M.D.; Wells, C.W.; Platts-Mills, T.A.

    1981-01-01

    Using an inhibition radioimmunoassay for the major allergen from Dermatophagoides pteronyssinus (antigen P1), we studied the distribution of this dust allergen in the houses of patients with asthma. Both bed and floor dust samples contained a wide range of antigen P1, 100 to 100,000 ng/g of fine dust, and this concentration correlated well with the number of mite bodies (r . 0.81, p less than 0.001). We were unable to detect antigen P1 in the air of undisturbed rooms. However, during domestic activity, between 1 and 30 ng were collected on a filter than sampled air for 45 min at 17 L/min. Using a cascade impactor it was shown that greater than 80% of the airborne antigen P1 was associated with particles greater than 10 mu in diameter. Some of the particles containing allergen could be identified because they formed precipitin rings when impacted onto agarose containing rabbit antimite antiserum. These particles had the physical appearance of mite feces, which are the major source of antigen P1 in mite cultures. The results suggested that natural exposure to this dust allergen allows occasional fecal particles to enter the lungs and that these particles contain very concentrated allergen

  4. Development of water scrubbers to reduce fine dust emission from poultry houses

    NARCIS (Netherlands)

    Ogink, N.W.M.; Aarnink, A.J.A.; Harn, van J.; Melse, R.W.; Cambra-Lopez, M.

    2010-01-01

    Poultry housings with litter are a major contributor to fine dust emissions (PM10/PM2.5) in the Netherlands. Poultry producers are in need of dust mitigation options that are cost effective. Such an option could be provided by adequately designed water scrubbers. Catchment of dust particles by water

  5. Analysis of mechanism of PM2.5 and house dust mite antigen Der p1 in attack stage of child asthma.

    Science.gov (United States)

    Cheng, Q; Yang, C-Y; Guo, B-Y; Wei, X; Liu, M

    2017-05-01

    We analyzed the influence of PM2.5 and house dust mite antigen Der p1 on the treatment of child asthma attack. A total of 96 children with asthma attack were included into the study. The patients were randomly divided into the PM2.5 group, the house dust mite antigen group, the synergistic group and the control group (n= 24 in each group). The PM2.5 concentration in the PM2.5 group was twice higher than standard level (≤ the average value of PM2.5 in local air). All cases were given with same treatment, and the treatment effects were compared and analyzed. It was found that the asthma control rate in the control group was significantly higher than that in the PM2.5 group and the house dust mite antigen group, and the synergistic group was the lowest. The control time in the synergistic group was significantly longest, followed by the PM2.5 group and the house dust mite antigen group, and the control group was significantly short (pasthma attack by an inflammatory reaction and oxidative stress.

  6. Pesticides in house dust from urban and farmworker households in California: an observational measurement study

    Directory of Open Access Journals (Sweden)

    McKone Thomas E

    2011-03-01

    Full Text Available Abstract Background Studies report that residential use of pesticides in low-income homes is common because of poor housing conditions and pest infestations; however, exposure data on contemporary-use pesticides in low-income households is limited. We conducted a study in low-income homes from urban and agricultural communities to: characterize and compare house dust levels of agricultural and residential-use pesticides; evaluate the correlation of pesticide concentrations in samples collected several days apart; examine whether concentrations of pesticides phased-out for residential uses, but still used in agriculture (i.e., chlorpyrifos and diazinon have declined in homes in the agricultural community; and estimate resident children's pesticide exposures via inadvertent dust ingestion. Methods In 2006, we collected up to two dust samples 5-8 days apart from each of 13 urban homes in Oakland, California and 15 farmworker homes in Salinas, California, an agricultural community (54 samples total. We measured 22 insecticides including organophosphates (chlorpyrifos, diazinon, diazinon-oxon, malathion, methidathion, methyl parathion, phorate, and tetrachlorvinphos and pyrethroids (allethrin-two isomers, bifenthrin, cypermethrin-four isomers, deltamethrin, esfenvalerate, imiprothrin, permethrin-two isomers, prallethrin, and sumithrin, one phthalate herbicide (chlorthal-dimethyl, one dicarboximide fungicide (iprodione, and one pesticide synergist (piperonyl butoxide. Results More than half of the households reported applying pesticides indoors. Analytes frequently detected in both locations included chlorpyrifos, diazinon, permethrin, allethrin, cypermethrin, and piperonyl butoxide; no differences in concentrations or loadings were observed between locations for these analytes. Chlorthal-dimethyl was detected solely in farmworker homes, suggesting contamination due to regional agricultural use. Concentrations in samples collected 5-8 days apart in

  7. Coal-tar-based parking lot sealcoat: An unrecognized source of PAH to settled house dust

    Science.gov (United States)

    Mahler, B.J.; Van Metre, P.C.; Wilson, J.T.; Musgrove, M.; Burbank, T.L.; Ennis, T.E.; Bashara, T.J.

    2010-01-01

    Despite much speculation, the principal factors controlling concentrations of polycyclic aromatic hydrocarbons (PAH) in settled house dust (SHD) have not yet been identified. In response to recent reports that dust from pavement with coaltar-based sealcoat contains extremely high concentrations of PAH, we measured PAH in SHD from 23 apartments and in dust from their associated parking lots, one-half of which had coal-tar-based sealcoat (CT). The median concentration of total PAH (T-PAH) in dust from CT parking lots (4760 ??g/g, n = 11) was 530 times higher than that from parking lots with other pavement surface types (asphalt-based sealcoat, unsealed asphalt, concrete [median 9.0 ??g/g, n = 12]). T-PAH in SHD from apartments with CT parking lots (median 129 ??g/g) was 25 times higher than that in SHD from apartments with parking lots with other pavement surface types (median 5.1 ??g/g). Presence or absence of CT on a parking lot explained 48% of the variance in log-transformed T-PAH in SHD. Urban land-use intensity near the residence also had a significant but weaker relation to T-PAH. No other variables tested, including carpeting, frequency of vacuuming, and indoor burning, were significant. ?? 2010 American Chemical Society.

  8. Radiocesium contamination in house dust within evacuation areas close to the Fukushima Daiichi nuclear power plant.

    Science.gov (United States)

    Shinohara, Naohide; Yoshida-Ohuchi, Hiroko

    2018-05-01

    Outdoor decontamination efforts have been ongoing since the Fukushima Daiichi nuclear power plant (FDNPP) accident; however, little is known about indoor contamination. Therefore, house dust was sampled based on particle size in 21 wooden buildings (19 residential houses and 2 community centers) within the evacuation area close to the FDNPP, Fukushima Prefecture, Japan. Activities of radiocesium ( 137 Cs) per gram of house dust increased with decreasing particle size (mean: 6.1 × 10 3 , 2.6 × 10 3 , 1.6 × 10 3 , 7.5 × 10 2 , 5.0 × 10 2 , and 4.6 × 10 2  Bq/g for house dust were inversely related to the square of distance from the FDNPP for house dust. It was found that 19%, 33%, and 48% of 137 Cs in house dust were extracted in water, 1 M HCl, and not extracted, respectively. Considering the bioaccessibility and assuming a 20 mg/day daily intake of house dust, the daily doses would be 7.2 Bq/day (mean) and 18 Bq/day (95th percent quantile). These results provide valuable insight into indoor radioactive Cs contamination in the area around the FDNPP and possible oral exposure to indoor radioactive Cs after returning home. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. A study on the prevalence of house dust mites in Al-Arish city, North Sinai Governorate, Egypt.

    Science.gov (United States)

    El-Sherbiny, Gihad T; El-Sherbini, Eman T; Saled, Nagla Mostafa K; Haridy, Fouad M; Morsy, Ayman T A

    2010-04-01

    Free living mites comprise a huge and various groups of tiny arthropods in the class Arachida, mainly of the Pyroglyphidae family. Exposure to allergens derived from house dust mite (HDM) feces is a postulated risk factor for allergic sensitization, asthma development and asthma morbidity. However, practical and effective method to mitigate these allergens in low-income, urban home environments remains elusive. It well known that (HDM) physiology is greatly affected by hydrothermal microclimatic condition. El Arish has subtropical climate and warm humid summer, such situation are favourable to proliferate house dust mites. As no valid data are available for house dust mites fauna of El Arish, this study was carried out to determine the prevalence and contamination rates of homes in El Arish city. Samples of house dust collected in 2008 from 50 houses in El Arish city were subjected to acarological examination. Acri were found in (34.6 %) of the samples collected from these homes. Results indicated that dust mites were present in all humid environments. Also, hypersensitivity to dust mites was common among patients with asthma.

  10. House dust mite reduction and avoidance measures for treating eczema.

    Science.gov (United States)

    Nankervis, Helen; Pynn, Emma V; Boyle, Robert J; Rushton, Lesley; Williams, Hywel C; Hewson, Deanne M; Platts-Mills, Thomas

    2015-01-19

    Eczema is an inflammatory skin disease that tends to involve skin creases, such as the folds of the elbows or knees; it is an intensely itchy skin condition, which can relapse and remit over time. As many as a third of people with eczema who have a positive test for allergy to house dust mite have reported worsening of eczema or respiratory symptoms when exposed to dust. To assess the effects of all house dust mite reduction and avoidance measures for the treatment of eczema. We searched the following databases up to 14 August 2014: the Cochrane Skin Group Specialised Register, CENTRAL in The Cochrane Library (2014, Issue 8), MEDLINE (from 1946), Embase (from 1974), LILACS (from 1982), and the GREAT database. We also searched five trials registers and checked the reference lists of included and excluded studies for further references to relevant studies. We handsearched abstracts from international eczema and allergy meetings. Randomised controlled trials (RCTs) of any of the house dust mite reduction and avoidance measures for the treatment of eczema, which included participants of any age diagnosed by a clinician with eczema as defined by the World Allergy Organization. We included all non-pharmacological and pharmacological interventions that sought to reduce or avoid exposure to house dust mite and their allergenic faeces. The comparators were any active treatment, no treatment, placebo, or standard care only. Two authors independently checked the titles and abstracts identified, and there were no disagreements. We contacted authors of included studies for additional information. We assessed the risk of bias using Cochrane methodology. We included seven studies of 324 adults and children with eczema. Overall, the included studies had a high risk of bias. Four of the seven trials tested interventions with multiple components, and three tested a single intervention. Two of the seven trials included only children, four included children and adults, and one

  11. Associations between flame retardant applications in furniture foam, house dust levels, and residents' serum levels.

    Science.gov (United States)

    Hammel, Stephanie C; Hoffman, Kate; Lorenzo, Amelia M; Chen, Albert; Phillips, Allison L; Butt, Craig M; Sosa, Julie Ann; Webster, Thomas F; Stapleton, Heather M

    2017-10-01

    Polyurethane foam (PUF) in upholstered furniture frequently is treated with flame retardant chemicals (FRs) to reduce its flammability and adhere to rigorous flammability standards. For decades, a commercial mixture of polybrominated diphenyl ethers (PBDEs) called PentaBDE was commonly applied to foam to fulfill these regulations; however, concerns over toxicity, bioaccumulation, and persistence led to a global phase-out in the mid-2000s. Although PentaBDE is still detected in older furniture, other FR compounds such as tris(1,3-dichloroisopropyl) phosphate (TDCIPP) and Firemaster® 550 (FM550) have been increasingly used as replacements. While biomonitoring studies suggest exposure is widespread, the primary sources of exposure are not clearly known. Here, we investigated the relationships between specific FR applications in furniture foam and human exposure. Paired samples of furniture foam, house dust and serum samples were collected from a cohort in North Carolina, USA and analyzed for FRs typically used in PUF. In general, the presence of a specific FR in the sofa of a home was associated with an increase in the concentration of that FR in house dust. For example, the presence of PentaBDE in sofas was associated with significantly higher levels of BDE-47, a major component of PentaBDE, in house dust (10 β =6.4, phouse dust when FM550 was identified in the sofa foam (p<0.01). These relationships were modified by dust loading rates in the living room and the ratio of sofa size to room size. Interestingly, levels of TDCIPP and tris(1-chloro-2-isopropyl) phosphate (TCIPP) were also higher in dust with detections in sofa foam; however, these associations were not statistically significant and may suggest there are other prominent sources of these compounds in the home. In addition, the presence of PentaBDE in sofa foam was associated with significantly higher levels of BDE-47 in serum (p<0.01). These results suggest that FR applications in sofas are likely major

  12. Control of house-dust mites with home disinfectants

    NARCIS (Netherlands)

    Schober, G.; Wetter, G.; Bischoff, E.; Bronswijk, van J.E.M.H.; Kniest, F.M.

    1987-01-01

    Chemical disinfectants and biocidal preparations used in households were tested in the laboratory for their ability to kill the house-dust miteDermatophagoides farinae. Batches of ten specimens were soaked in aqueous solutions or suspensions containing 0.0, 0.1, 0.3, 1.0, 3.0 and 10.0% (by volume)

  13. House dust mites on skin, clothes, and bedding of atopic dermatitis patients.

    Science.gov (United States)

    Teplitsky, Valery; Mumcuoglu, Kosta Y; Babai, Ilan; Dalal, Ilan; Cohen, Rifka; Tanay, Amir

    2008-08-01

    Atopic dermatitis is a common allergic condition in children, often associated with a positive skin reaction to house dust mite allergens. To determine the presence of house dust mites on the skin, clothes, and bedding of patients with atopic dermatitis. Nineteen patients with atopic dermatitis were examined during a 2-year period. Samples from affected and healthy skin surfaces were obtained with adhesive tape, and dust samples from bedding and clothes were collected with a vacuum cleaner at the start of the study and 3-6 weeks later, and examined for the presence of house dust mites. The findings were compared with those of 21 healthy controls. The most common mite species on skin were Dermatophagoides pteronyssinus and Dermatophagoides farinae, which were found in nine patients and three controls. The patient group showed a significantly larger percentage of samples with mites than did the control group (34.9% and 7.9%, respectively) (P bedding of patients, or between patients and controls with regard to the number of mites on the clothes and bedding. Patients with atopic dermatitis showed a higher prevalence of mites on their skin than did healthy individuals, which could be involved in allergic sensitization and disease exacerbation.

  14. Pheromonal Communication in the European House Dust Mite, Dermatophagoides pteronyssinus

    Directory of Open Access Journals (Sweden)

    Johannes L.M. Steidle

    2014-08-01

    Full Text Available Despite the sanitary importance of the European house dust mite Dermatophagoides pteronyssinus (Trouessart, 1897, the pheromonal communication in this species has not been sufficiently studied. Headspace analysis using solid phase micro extraction (SPME revealed that nerol, neryl formate, pentadecane, (6Z,9Z-6,9-heptadecadiene, and (Z-8-heptadecene are released by both sexes whereas neryl propionate was released by males only. Tritonymphs did not produce any detectable volatiles. In olfactometer experiments, pentadecane and neryl propionate were attractive to both sexes as well as to tritonymphs. (Z-8-heptadecene was only attractive to male mites. Therefore it is discussed that pentadecane and neryl propionate are aggregation pheromones and (Z-8-heptadecene is a sexual pheromone of the European house dust mite D. pteronyssinus. To study the potential use of pheromones in dust mite control, long-range olfactometer experiments were conducted showing that mites can be attracted to neryl propionate over distances of at least 50 cm. This indicates that mite pheromones might be useable to monitor the presence or absence of mites in the context of control strategies.

  15. The crystal structure of recombinant proDer p 1, a major house dust mite proteolytic allergen

    DEFF Research Database (Denmark)

    Meno, Kåre; Thorsted, Peter B; Ipsen, Henrik

    2005-01-01

    Allergy to house dust mite is among the most prevalent allergic diseases worldwide. Most house dust mite allergic patients react to Der p 1 from Dermatophagoides pteronyssinus, which is a cysteine protease. To avoid heterogeneity in the sample used for crystallization, a modified recombinant...

  16. Effect of Bedding Material on Dust and Ammonia Emission from Broiler Houses

    NARCIS (Netherlands)

    Harn, van J.; Aarnink, A.J.A.; Mosquera Losada, J.; Riel, van J.W.; Ogink, N.W.M.

    2012-01-01

    Ammonia emission, Bedding material, Broilers, Dust emission The objective of this study was to determine the effects of different bedding materials on fine dust (PM10 and PM2.5) and ammonia emissions from broiler houses. The effects on broiler performance and footpad lesions were also studied. The

  17. Acaricidal activities of some essential oils and their monoterpenoidal constituents against house dust mite, Dermatophagoides pteronyssinus (Acari: Pyroglyphidae).

    Science.gov (United States)

    Saad, El-Zemity; Hussien, Rezk; Saher, Farok; Ahmed, Zaitoon

    2006-12-01

    The acaricidal activities of fourteen essential oils and fourteen of their major monoterpenoids were tested against house dust mites Dermatophagoides pteronyssinus. Five concentrations were used over two different time intervals 24 and 48 h under laboratory conditions. In general, it was noticed that the acaricidal effect based on LC(50) of either essential oils or monoterpenoids against the mite was time dependant. The LC(50) values were decreased by increasing of exposure time. Clove, matrecary, chenopodium, rosemary, eucalyptus and caraway oils were shown to have high activity. As for the monoterpenoids, cinnamaldehyde and chlorothymol were found to be the most effective followed by citronellol. This study suggests the use of the essential oils and their major constituents as ecofriendly biodegradable agents for the control of house dust mite, D. pteronyssinus.

  18. Effect of mattress and pillow encasings on children with asthma and house dust mite allergy

    DEFF Research Database (Denmark)

    Halken, Susanne; Høst, Arne; Niklassen, Ulla

    2003-01-01

    House dust mite (HDM) allergy is a frequent cause of allergic asthma in children. Reduction of exposure seems to be the most logical way to treat these patients.......House dust mite (HDM) allergy is a frequent cause of allergic asthma in children. Reduction of exposure seems to be the most logical way to treat these patients....

  19. Electronic design of air dust concentration gauge

    International Nuclear Information System (INIS)

    Machaj, B.; Strzalkowski, J.; Krawczynska, B.

    1993-01-01

    A new version of isotope dust concentration gauge for monitoring airborne dust pollution of air employs a ready made personal computer as the control and processing unit in the gauge instead of specialized electronics. That solution of the gauge reduces the needed specialized electronics to a simple computer interface coupling the computer to the measuring head. This also reduced electronics of the measuring head itself, i.e. GM detector circuit, power supplies and electronic circuits to switch on/off driving motors. The functioning and operation of the gauge is controlled by the computer program that can be easily modified if needed. The computer program for the gauge enables automatic measurements of dust concentration. Up to fifty measuring cycles can be easily programmed for a day. The results of measurements are presented in the form of data collection, diagram of dust concentration distribution during one day, diagram of dust distribution during 30 successive days or diagram of average dust concentration distribution during a day which may be computed by combining data of the selected number of measurements. Recalibration of the gauge and checking up of the gauge are also carried out under the program control. (author). 6 refs, 9 figs

  20. Sublingual immunotherapy in patients with house dust mite allergic rhinitis: prospective study of clinical outcomes over a two-year period.

    Science.gov (United States)

    Soh, J Y; Thalayasingam, M; Ong, S; Loo, E X L; Shek, L P; Chao, S S

    2016-03-01

    Sublingual immunotherapy in patients with allergic rhinitis sensitised to house dust mites is safe, but its efficacy is controversial and sublingual immunotherapy with Blomia tropicalis has not yet been studied. This study sought to evaluate the efficacy of sublingual immunotherapy with house dust mite extract in children and adults with house dust mite allergic rhinitis over a period of two years. A prospective observational study was conducted of children and adults diagnosed with house dust mite allergic rhinitis who were treated with sublingual immunotherapy from 2008 to 2012. Total Nasal Symptom Scores, Mini Rhinoconjunctivitis Quality of Life scores and medication usage scores were assessed prospectively. Thirty-nine patients, comprising 24 children and 15 adults, were studied. Total Nasal Symptom Scores and Mini Rhinoconjunctivitis Quality of Life scores dropped significantly at three months into therapy, and continued to improve. Medication usage scores improved at one year into immunotherapy. Sublingual immunotherapy with house dust mite extracts, including B tropicalis, is efficacious as a treatment for patients with house dust mite allergic rhinitis.

  1. Mice housed on coal dust-contaminated sand: A model to evaluate the impacts of coal mining on health.

    Science.gov (United States)

    Caballero-Gallardo, Karina; Olivero-Verbel, Jesus

    2016-03-01

    Coal dust is the most important air pollutant in coal mining in regards to producing deleterious health effects. It permeates the surrounding environment threatening public health. The aim of this study was to evaluate the toxic effects associated with exposure to sand contaminated with coal dust particles below 38 μm in diameter, obtained from a mineral sample collected in the largest coal mine in South America, La Loma, Cesar, Colombia. Sterilized sand was spiked with coal dust to obtain concentrations ranging from zero to 4% coal dust. To model natural exposure, mice were housed for eight weeks in boxes containing this mixture as bedding after which, they were euthanized and blood and tissue samples were collected. Real time PCR analysis revealed an increase in Cyp1A1 mRNA for living on sand with coal dust concentrations greater than 2% compared to mice living on sand without coal dust. Unexpectedly, for mice on coal dust-polluted sand, Sod1, Scd1 and Nqo1 hepatic mRNA were downregulated. The Comet assay in peripheral blood cells and the micronucleus test in blood smears, showed a significant potential genotoxic effect only at the highest coal dust concentration. Histopathological analysis revealed vascular congestion and peribronchial inflammation in the lungs. A dose-response relationship for the presence of hepatic steatosis, vacuolization and nuclei enlargements was observed in the exposed animals. The data suggest living on a soil polluted with coal dust induces molecular, cellular and histopathological changes in mice. Accordingly, the proposed model can be used to identify deleterious effects of exposure to coal dust deposited in soils that may pose health risks for surrounding wildlife populations. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. House dust in seven Danish offices

    Science.gov (United States)

    Mølhave, L.; Schneider, T.; Kjærgaard, S. K.; Larsen, L.; Norn, S.; Jørgensen, O.

    Floor dust from Danish offices was collected and analyzed. The dust was to be used in an exposure experiment. The dust was analyzed to show the composition of the dust which can be a source of airborne dust indoors. About 11 kg of dust from vacuum cleaner bags from seven Danish office buildings with about 1047 occupants (12 751 m 2) was processed according to a standardized procedure yielding 5.5 kg of processed bulk dust. The bulk dust contained 130.000-160.000 CFU g -1 microorganisms and 71.000-90.000 CFU g -1 microfungi. The content of culturable microfungi was 65-123 CFU 30 g -1 dust. The content of endotoxins ranged from 5.06-7.24 EU g -1 (1.45 ng g -1 to 1.01 ng g -1). Allergens (ng g -1) were from 147-159 (Mite), 395-746 (dog) and 103-330 (cat). The macro molecular organic compounds (the MOD-content) varied from 7.8-9.8 mg g -1. The threshold of release of histamine from basophil leukocytes provoked by the bulk dust was between 0.3 and 1.0 mg ml -1. The water content was 2% (WGT) and the organic fraction 33%. 6.5-5.9% (dry) was water soluble. The fiber content was less than 0.2-1.5% (WGT) and the desorbable VOCs was 176-319 μg g -1. Most of the VOC were aldehydes. However, softeners for plastic (DBP and DEHP) were present. The chemical composition includes human and animal skin fragments, paper fibers, glass wool, wood and textilefibers and inorganic and metal particles. The sizes ranged from 0.001-1 mm and the average specific density was 1.0 g m -3. The bulk dust was resuspended and injected into an exposure chamber. The airborne dust was sampled and analyzed to illustrate the exposures that can result from sedimented dirt and dust. The airborne dust resulting from the bulk dust reached concentrations ranging from 0.26-0.75 mg m -3 in average contained 300-170 CFU m -3. The organic fraction was from 55-70% and the water content about 2.5% (WGT). The content of the dust was compared to the similar results reported in the literature and its toxic potency is

  3. Mice housed on coal dust-contaminated sand: A model to evaluate the impacts of coal mining on health

    Energy Technology Data Exchange (ETDEWEB)

    Caballero-Gallardo, Karina, E-mail: kcaballerog@unicartagena.edu.co; Olivero-Verbel, Jesus, E-mail: joliverov@unicartagena.edu.co

    2016-03-01

    Coal dust is the most important air pollutant in coal mining in regards to producing deleterious health effects. It permeates the surrounding environment threatening public health. The aim of this study was to evaluate the toxic effects associated with exposure to sand contaminated with coal dust particles below 38 μm in diameter, obtained from a mineral sample collected in the largest coal mine in South America, La Loma, Cesar, Colombia. Sterilized sand was spiked with coal dust to obtain concentrations ranging from zero to 4% coal dust. To model natural exposure, mice were housed for eight weeks in boxes containing this mixture as bedding after which, they were euthanized and blood and tissue samples were collected. Real time PCR analysis revealed an increase in Cyp1A1 mRNA for living on sand with coal dust concentrations greater than 2% compared to mice living on sand without coal dust. Unexpectedly, for mice on coal dust-polluted sand, Sod1, Scd1 and Nqo1 hepatic mRNA were downregulated. The Comet assay in peripheral blood cells and the micronucleus test in blood smears, showed a significant potential genotoxic effect only at the highest coal dust concentration. Histopathological analysis revealed vascular congestion and peribronchial inflammation in the lungs. A dose–response relationship for the presence of hepatic steatosis, vacuolization and nuclei enlargements was observed in the exposed animals. The data suggest living on a soil polluted with coal dust induces molecular, cellular and histopathological changes in mice. Accordingly, the proposed model can be used to identify deleterious effects of exposure to coal dust deposited in soils that may pose health risks for surrounding wildlife populations. - Highlights: • Mice were exposed to coal dust-contaminated sand. • mRNA Markers for PAH exposure, lipid metabolism and oxidative stress increased. • ALT activity in plasma increased at the highest exposure to coal dust. • Liver tissues of exposed

  4. Antigenic relationship between the house dust mite Dermatophagoides farinae and the predacious mite Phytoseiulus persimilis.

    Science.gov (United States)

    Homma, R; Ando, T; Miyahara, A; Kimura, H; Ito, G; Uesato, N; Ino, Y; Iwaki, M

    1994-12-01

    We have examined the antigenic relationship between the house dust mite Dermatophagoides farinae and the predacious mite Phytoseiulus persimilis. Immunoblotting analysis demonstrated that there was a very weak antigenic cross-reactivity between these different suborder of mites but that this cross-reactivity was not attributed to D. farinaes major allergen's, Der fI and Der fII. These results suggest that P. persimilis might scarcely provoke allergic symptoms in patients sensitized to house dust mites.

  5. On the abundance of Dermatophagoides pteronyssinus (Trouessart, 1897) (Pyroglyphidae: Acarina) in house dust

    NARCIS (Netherlands)

    Bronswijk, van J.E.M.H.; Schoonen, J.M.C.P.; Berlie, M.A.F.; Lukoschus, F.S.

    1971-01-01

    The dominance of the Pyroglyphidae in house dust has been influenced by a number of factors. The humidity in houses dropped recently to such an extent that only Pyroglyphidae can survive. When temperature and relative humidity are favorable for Acarus siro and Glycyphagus destructor as well as

  6. House dust and storage mite contamination of dry dog food stored in open bags and sealed boxes in 10 domestic households.

    Science.gov (United States)

    Gill, Christina; McEwan, Neil; McGarry, John; Nuttall, Tim

    2011-04-01

    Dry pet food is a potential source of exposure to house dust and storage mite allergens in canine atopic dermatitis. This study evaluated contamination of house dust and dry dog food stored in paper bags, sealable plastic bags and sealable plastic boxes in 10 households for 90 days using Acarex(®) tests for guanine, a Der p 1 ELISA and mite flotation. Acarex(®) tests were negative in all the food samples but positive in all the house dust samples. The Der p 1 levels and mite numbers significantly increased in food from paper bags (P = 0.0073 and P = 0.02, respectively), but not plastic bags or boxes. Mite numbers and Der p 1 levels were 10-1000 times higher in house dust than the corresponding food samples (P bags (P = 0.003), and mite numbers in house dust and food from the paper bags (P = 0.0007). Bedding and carpets were significantly associated with Der p 1 levels in house dust (P = 0.015 and P = 0.01, respectively), and food from the paper (both P = 0.02) and plastic bags (P = 0.03 and P = 0.04, respectively). Mites were identified in six of 10 paper bag, three of 10 plastic bag, one of 10 plastic box and nine of 10 house dust samples. These comprised Dermatophagoides (54%), Tyrophagus (10%; all from food) and unidentified mites (36%). Storage of food in sealable plastic boxes largely prevented contamination for 3 months. Exposure to mites and mite proteins in all the stored food, however, appeared to be trivial compared with house dust. © 2010 The Authors. Journal compilation © 2010 ESVD and ACVD.

  7. [Clinical investigation of basophil activation test as a complementary test for house dust mite allergen].

    Science.gov (United States)

    Ren, H L; Li, J D; Miao, Y H; Xu, T

    2018-03-01

    Objective: To investigate the clinical application of glass micro fiber basophil activation test (BAT) used as a complementary test for house dust mite allergen. Method: Forty patients with clinical diagnosed allergic rhinitis was test by three methods for house dust mite allergen, skin prick test(SPT),Immuno CAP sIgE, and BAT in vitro. The sensitivity and specificity of glass micro fiber were accessed, and the consistency between BAT, SPT, and Immuno sIgE was analyzed. As in vivo provocation was not performed, gold standard is regarded as the combination of medical history and positive reports of SPT and/or ImmunoCAP sIgE test. Result: Twentythree patients are diagnosed as house dust mite allergic rhinitis by gold standard. The sensitivity and specificity of glass micro fiber BAT were 60.9% and 88.2%, the sensitivity of SPT and sIgE was 87.0% and sIgE 73.9%. The correlation rates between BAT with SPT is 0.67( P house dust mite allergic rhinitis, BAT have a good consistency with SPT and sIgE, while as it has only moderate consistency with "gold standard", further studies are needed to prove its clinical significance. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  8. The Spatial Variation of Dust Particulate Matter Concentrations during Two Icelandic Dust Storms in 2015

    Directory of Open Access Journals (Sweden)

    Pavla Dagsson-Waldhauserova

    2016-06-01

    Full Text Available Particulate matter mass concentrations and size fractions of PM1, PM2.5, PM4, PM10, and PM15 measured in transversal horizontal profile of two dust storms in southwestern Iceland are presented. Images from a camera network were used to estimate the visibility and spatial extent of measured dust events. Numerical simulations were used to calculate the total dust flux from the sources as 180,000 and 280,000 tons for each storm. The mean PM15 concentrations inside of the dust plumes varied from 10 to 1600 µg·m−3 (PM10 = 7 to 583 µg·m−3. The mean PM1 concentrations were 97–241 µg·m−3 with a maximum of 261 µg·m−3 for the first storm. The PM1/PM2.5 ratios of >0.9 and PM1/PM10 ratios of 0.34–0.63 show that suspension of volcanic materials in Iceland causes air pollution with extremely high PM1 concentrations, similar to polluted urban areas in Europe or Asia. Icelandic volcanic dust consists of a higher proportion of submicron particles compared to crustal dust. Both dust storms occurred in relatively densely inhabited areas of Iceland. First results on size partitioning of Icelandic dust presented here should challenge health authorities to enhance research in relation to dust and shows the need for public dust warning systems.

  9. Determinants of house dust, endotoxin, and β-(1→3)-d-glucan in homes of Danish children

    DEFF Research Database (Denmark)

    Holst, Gitte Juel; Høst, Arne; Doekes, G

    2015-01-01

    Little is known about the geographic variation and determinants of bacterial endotoxin and β -(1,3)-d-glucan in Danish house dust. In a population of 317 children, we: (i) described loads and concentrations of floor dust, endotoxin, and β-(1→3)-d-glucan and (ii) their correlations and (iii......) assessed their determinants; (iv) Finally, we compared our findings with previous European studies. Bedroom floor dust was analyzed for endotoxin content by the kinetic limulus amoebocyte lysate assay and for β-(1→3)-d-glucan by the inhibition enzyme immunoassay. The parents answered questions regarding...... potential determinants. We found: geometric means (geometric standard deviations) 186 mg/m(2) (4.3) for dust; 5.46 × 10(3) EU/m(2) (8.0) and 31.1 × 10(3) EU/g (2.6) for endotoxin; and 142 μg/m(2) (14.3) and 0.71 × 10(3) μg/g (7.3) for β-(1→3)-d-glucan. High correlations (r > 0.75) were found between floor...

  10. Dust in Snow in the Colorado River Basin: Spatial Variability in Dust Concentrations, Radiative Forcing, and Snowmelt Rates

    Science.gov (United States)

    Skiles, M.; Painter, T.; Deems, J. S.; Landry, C.; Bryant, A.

    2012-12-01

    Since the disturbance of the western US that began with the Anglo settlement in the mid 19th century, the mountain snow cover of the Colorado River Basin (CRB) has been subject to five-fold greater dust loading. This dust deposition accelerates snowmelt through its direct reduction of albedo and its further reduction of albedo by accelerating the growth of snow effective grain size. We have previously quantified the impacts of dust in snow using a 6-year record of dust concentration and energy balance fluxes at the alpine and subalpine towers in the Senator Beck Basin Study Area (SBBSA), San Juan Mountains in southwestern Colorado, USA. Dust loading exhibited interannual variability, and end of year dust concentrations were not necessarily related to the number of dust deposition events. Radiative forcing enhanced springtime melt by 21 to 51 days with the magnitude of advanced loss being linearly related to total dust concentration at the end of snow cover. To expand our understanding of dust on snow deposition patterns we utilize collections of dust concentration at the Colorado Dust on Snow (CODOS) study sites, established in 2009 along the western side of the CRB, to assess spatial variability in dust loading. In situ sampling of dust stratigraphy and concentration occurs twice each season, once over peak snow water equivalent (15 April), and again during melt (15 May). Dust loading occurs at all sites; dust concentrations are always higher in May, vary between sites, and the highest and lowest dust years were 2009 and 2012, respectively. In the absence of regular sampling and energy balance instrumentation these sites do not allow us to quantify the advanced melt due to dust. To facilitate this a new energy balance site, Grand Mesa Study plot (GMSP), was established for water year 2010 in west central Colorado, 150 km north of SBBSA. Back trajectories indicate similar Colorado Plateau dust sources at both SBBSA and GMSP, yet GMSP exhibits slightly lower dust

  11. Activation of human peroxisome-activated receptor-gamma (PPARy) by house dust extracts

    Science.gov (United States)

    Obesity in children has become an epidemic and recent research suggests a possible contribution from exposure to environmental chemicals. Several chemicals, such as phthalates, brominated flame retardants, and perfluorinated chemicals, are common in house dust on floors where chi...

  12. Evaluation of Airborne MDF Dust Concentration in Furniture Factories

    Directory of Open Access Journals (Sweden)

    Renilson Luiz Teixeira

    2017-10-01

    Full Text Available ABSTRACT High concentrations of airborne dust are observed during the cutting of medium density fiberboard (MDF boards. This dust, at first considered just uncomfortable for workers, may be harmful to their health. The objective of this work was to evaluate the concentration of airborne dust during the cutting of medium density fiberboard (MDF. The experiment was developed in the MDF cutting sector of three furniture factories located in the city of Lavras/MG. The results showed that the mean concentrations of total dust suspended in these three furniture factories were above the tolerance limit set by the American Conference of Governmental Industrial Hygienists (ACGIH, giving evidence of a serious problem in these companies related to this type of risk agent.

  13. A Three-Year Course of House Dust Mite Sublingual Immunotherapy Appears Effective in Controlling the Symptoms of Allergic Rhinitis.

    Science.gov (United States)

    Novakova, Silviya M; Novakova, Plamena I; Yakovliev, Plamen H; Staevska, Maria T; Mateva, Nonka G; Dimcheva, Teodora D; Peichev, Jivko L

    2018-05-01

    Background Allergic rhinitis is the most common allergic disorder. Although the management of the disease is successful in many patients, based on guidelines, some of them remain with symptoms uncontrolled with pharmacotherapy. Presently, there is no substantiated information on the control of allergic rhinitis in patients who underwent sublingual immunotherapy. Objective The purpose of this prospective follow-up study was to assess the control of allergic rhinitis in adults after a three-year course of house dust mite sublingual immunotherapy. Methods This prospective real-life study was designed to include adults with moderate to severe allergic rhinitis sensitized to house dust mite who underwent a three-year course of sublingual immunotherapy. Control of symptoms was assessed by Rhinitis Control Assessment Test (RCAT) after three years of house dust mite sublingual immunotherapy. Additionally, patients assessed their symptoms by utilizing a visual analog scale. Results A total number of 86 consecutively enrolled patients (46 (53.49%) men; mean age 26.10 years (SD = 5.85)) with moderate to severe allergic rhinitis and clinically relevant sensitization to house dust mite were evaluated. When assessed by RCAT on the third year, 74 (86.05%) had well-controlled symptoms and 20 (27.03%) of them were completely controlled. A significant reduction in visual analog scale scores-from 7.52 cm at baseline to 2.31 cm-was established ( P house dust mite sublingual immunotherapy appears effective in controlling the symptoms of allergic rhinitis.

  14. An assessment of hopanes in settled dust and air as indicators of exposure to traffic-related air pollution in Windsor, Ontario

    Science.gov (United States)

    Curran, Jason

    Traffic-related air pollution (TRAP) has been linked with several adverse health effects. We investigated hopanes, markers of primary particle emissions from gasoline and diesel engines, in house dust as an alternative approach for assessing exposure to TRAP in Windsor, Ontario. Settled house dust was collected from the homes of 28 study participants (10 -- 13 yrs). The dust was then analyzed for a suite of hopanes by gas chromatography-mass spectrometry. We calculated correlations between dust hopane concentrations and estimates of annual average NO2 concentrations derived from an existing LUR model. Hopanes were consistently present in detectable quantities in house dust. Annual average outdoor NO2 estimated was moderately correlated with hopanes in house dust (r = 0.46; pefficiency or the presence of an attached garage. Hopanes measured in settled house dust show promise as an indicator of long-term exposure to traffic-related air pollution. Keywords: hopane; air pollution; traffic; dust; exposure; TRAP.

  15. Dust Concentration and Emission in Protoplanetary Disks Vortices

    Science.gov (United States)

    Sierra, Anibal; Lizano, Susana; Barge, Pierre

    2017-12-01

    We study the dust concentration and emission in protoplanetary disks vortices. We extend the Lyra-Lin solution for the dust concentration of a single grain size to a power-law distribution of grain sizes n(a)\\propto {a}-p. Assuming dust conservation in the disk, we find an analytic dust surface density as a function of the grain radius. We calculate the increase of the dust-to-gas mass ratio ɛ and the slope p of the dust size distribution due to grain segregation within the vortex. We apply this model to a numerical simulation of a disk containing a persistent vortex. Due to the accumulation of large grains toward the vortex center, ɛ increases by a factor of 10 from the background disk value, and p decreases from 3.5 to 3.0. We find the disk emission at millimeter wavelengths corresponding to synthetic observations with ALMA and VLA. The simulated maps at 7 mm and 1 cm show a strong azimuthal asymmetry. This happens because, at these wavelengths, the disk becomes optically thin while the vortex remains optically thick. The large vortex opacity is mainly due to an increase in the dust-to-gas mass ratio. In addition, the change in the slope of the dust size distribution increases the opacity by a factor of two. We also show that the inclusion of the dust scattering opacity substantially changes the disks images.

  16. The effect of sub-floor heating on house-dust-mite populations on floors and in furniture.

    Science.gov (United States)

    de Boer, Rob

    2003-01-01

    It is well known that dehydrating conditions for house dust mites can be created by simply raising the temperature, causing loss of body water and eventually death. Thus, it can be expected that conditions for dust mites are less favourable on floors supplied with sub-floor heating. This was examined in a study of 16 houses with sub-floor heating and 21 without. The pattern of changes in air humidity and temperature on the floors was investigated and compared to known data of the tolerance of dust mites. Also the resident mite populations were compared. Floors with sub-floor heating had, on average, fewer mites, but the difference with unheated floors was small. It was remarkable that mite numbers were also lower in upholstered furniture. Another important observation was that some houses with sub-floor heating had high mite numbers, indicating that this type of heating is compatible with a thriving mite population. Temperature and humidity conditions of heated floors may allow mites not only to survive, but also to remain active in winter. A moderate increase in temperature, a moderate decrease in (absolute) air humidity, or a combination of both, will suffice to keep the humidity all winter below the Critical Equilibrium Humidity, the level of air humidity that is critical for mite growth and reproduction, hence for allergen production. However, it is argued that measures to suppress allergen production by house dust mites are likely to be far more effective if taken in summer rather than in winter.

  17. Experimental studies of two-stage centrifugal dust concentrator

    Science.gov (United States)

    Vechkanova, M. V.; Fadin, Yu M.; Ovsyannikov, Yu G.

    2018-03-01

    The article presents data of experimental results of two-stage centrifugal dust concentrator, describes its design, and shows the development of a method of engineering calculation and laboratory investigations. For the experiments, the authors used quartz, ceramic dust and slag. Experimental dispersion analysis of dust particles was obtained by sedimentation method. To build a mathematical model of the process, dust collection was built using central composite rotatable design of the four factorial experiment. A sequence of experiments was conducted in accordance with the table of random numbers. Conclusion were made.

  18. Interlaboratory comparison on 137Cs activity concentration in fume dust

    International Nuclear Information System (INIS)

    Tzika, Faidra; Hult, Mikael; Burda, Oleksiy; Arnold, Dirk; Sibbens, Goedele; Caro Marroyo, Belén; Gómez–Mancebo, Maria Belén; Peyrés, Virginia; Moser, Hannah; Ferreux, Laurent; Šolc, Jaroslav; Dryák, Pavel; Fazio, Aldo; Luca, Aurelian; Vodenik, Branko; Reis, Mario

    2015-01-01

    A comparison was conducted, between 11 European National Metrology Institutes and EC-JRC, on measurement of 137 Cs activity concentration in fume dust. As test material an activity standard produced from real contaminated fume dust was used. The standard material consisted of 13 cylindrical samples of compressed fume dust. The material contained 137 Cs and 60 Co of reference activity concentrations of (9.72±0.10) Bq/g and (0.450±0.018) Bq/g, respectively, for the reference date of 1 June 2013, determined using the comparison results. The organization and results of the intercomparison, as well as the process of obtaining reliable reference values are presented. - Highlights: • A European comparison was conducted on measurement of 137 Cs activity in fume dust. • Participants used high resolution gamma ray spectrometry. • Efficiency calibration included Monte Carlo, numerical and experimental methods. • Reference 137 Cs and 60 Co activity concentrations in the fume dust were determined. • A new traceable activity standard of fume dust matrix is available to end-users.

  19. Polybrominated diphenyl ethers (PBDEs) contents in house and car dust of Portugal by pressurized liquid extraction (PLE) and gas chromatography-mass spectrometry (GC-MS).

    Science.gov (United States)

    Cunha, S C; Kalachova, K; Pulkrabova, J; Fernandes, J O; Oliveira, M B P P; Alves, A; Hajslova, J

    2010-03-01

    Dust is the repository of various compounds including flame retardants. In this study an analytical method based on PLE extraction and gas chromatography-mass spectrometry was selected for the analysis of 16 PBDEs congeners in house and car dust samples collected in Portugal. The analytical performance of the method was validated using standard reference material (SRM); values from 90% to 109% and from 2% to 11% were obtained for recovery and precision, respectively. The PBDE congeners distribution in whole and sieved fractions of the dust samples, as well as influence of the source on the levels of these contaminants, were obtained. The wide range of PBDEs contents found in the dust samples indicates heterogeneous levels of contamination in these matrices. The clearest feature of the results obtained was that Deca-BDE was the main PBDE in both house and car dust samples. The total PBDEs measured in house dust (ranging from 34 to 1928 ng g(-1)) was lower than those found in car dust (ranging from 193 to 22955 ng g(-1)). However, house dust provides a major contribution to human exposure due to the time spent there, much higher than in cars. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  20. The effect of environmental parameters to dust concentration in air-conditioned space

    Science.gov (United States)

    Ismail, A. M. M.; Manssor, N. A. S.; Nalisa, A.; Yahaya, N.

    2017-08-01

    Malaysia has a wet and hot climate, therefore most of the spaces are air conditioned. The environment might affect dust concentration inside a space and affect the indoor air quality (IAQ). The main objective of this study is to study the dust concentration collected inside enclosed air-conditioned space. The measurement was done physically at four selected offices and two classrooms using a number of equipment to measure the dust concentration and environmental parameters which are temperature and relative air humidity. It was found that the highest dust concentration produced in office (temperature of 24.7°C, relative humidity of 66.5%) is 0.075 mg/m3, as compared to classroom, the highest dust concentration produced is 0.060 mg/m3 office (temperature of 25.9°C, relative humidity of 64.0%). However, both measurements show that value still within the safety level set by DOSH Malaysia (2005-2010) and ASHRAE 62.2 2016. The office contained higher dust concentration compared to classroom because of frequent movement transpires daily due to the functional of the offices.

  1. Radon concentration distribution mapping in a small detached house

    International Nuclear Information System (INIS)

    Muellerova, Monika; Moravcsik, Attila; Holy, Karol; Hutka, Miroslav; Hola, Olga

    2013-01-01

    Radon activity concentration was investigated in an older, single storey detached house. The rooms of the house are in contact with the bedrock. The house is fitted with plastic windows and populated mostly during the summer. Integral (Raduet) and continuous (AlphaGUARD) methods were used to measure the radon activity concentration. Average radon and thoron activity concentrations in the house were 150 Bq/m 3 and 40 Bq/m 3 , respectively. The impact of the house occupancy on radon activity concentration was significant only during the summer months when a decrease of radon activity concentration was recorded due to an increased ventilation rate. In the autumn and winter months, the impact of the house occupancy on radon activity concentration was relatively small - up to 20 %. The increases in radon activity concentration after the room had been thoroughly ventilated were analysed in order to estimate the ventilation rate and the rate of radon supply into the house. (orig.)

  2. Analysis of the CD4(+) T cell responses to house dust mite allergoid

    NARCIS (Netherlands)

    Kalinski, P.; Lebre, M. C.; Kramer, D.; de Jong, E. C.; van Schijndel, J. W. P. M.; Kapsenberg, M. L.

    2003-01-01

    Background: Modified allergen extracts (allergoids) with reduced IgE-binding capacity are successfully used in immunotherapy of atopic allergy. Their reduced T-cell stimulatory capacity is less well studied and is a subject of the present study. Methods: We compared the ability of native house dust

  3. Seasonal variations in house dust mite influence the circadian peak expiratory flow amplitude

    NARCIS (Netherlands)

    Postma, DS; vanderHeide, S; deReus, DM; Koeter, GH; vanAalderen, WMC; Meijer, G.

    1996-01-01

    The aim of the study was to investigate whether seasonal differences in house dust mite (HDM) allergen exposure influence the circadian peak expiratory flow (PEF) amplitude in asthmatic children. Asthmatic children (n = 25) with a solitary allergy to HDM were studied in spring and in autumn. All

  4. Time-dependent distinct roles of Toll-like receptor 4 in a house dust mite-induced asthma mouse model.

    Science.gov (United States)

    Ishii, T; Niikura, Y; Kurata, K; Muroi, M; Tanamoto, K; Nagase, T; Sakaguchi, M; Yamashita, N

    2018-03-01

    House dust mites (HDMs) are a common source of allergens that trigger both allergen-specific and innate immune responses in humans. Here, we examined the effect of allergen concentration and the involvement of Toll-like receptor 4 (TLR4) in the process of sensitization to house dust mite allergens in an HDM extract-induced asthma mouse model. Intranasal administration of HDM extract induced an immunoglobulin E response and eosinophilic inflammation in a dose-dependent manner from 2.5 to 30 μg/dose. In TLR4-knockout mice, the infiltration of eosinophils and neutrophils into the lung was decreased compared with that in wild-type mice in the early phase of inflammation (total of three doses). However, in the late phase of inflammation (total of seven doses), eosinophil infiltration was significantly greater in TLR4-knockout mice than in wild-type mice. This suggests that the roles of TLR4 signaling are different between the early phase and the later phase of HDM allergen-induced inflammation. Thus, innate immune response through TLR4 regulated the response to HDM allergens, and the regulation was altered during the phase of inflammation. © 2018 The Foundation for the Scandinavian Journal of Immunology.

  5. Long-range Transported African Dust in the Caribbean Region: Dust Concentrations and Water-soluble Ions

    Science.gov (United States)

    Santos-Figueroa, G.; Avilés-Piñeiro, G. M.; Mayol-Bracero, O. L.

    2017-12-01

    Long-range transported African dust (LRTAD) particles reach the Caribbean region every year during the summer months causing an increase in PM10 concentrations and by consequence degradation of air quality. During African dust (AD) incursions at the Caribbean region, PM10 concentration could exceeds the exposure limit of 50 µg/m³ 24-hour mean established by the World Health Organization (WHO). To have a better understanding of the impacts of AD particles to climate and public health at the Caribbean region it is necessary to study and determine the spatial and temporal distribution of dust particles. In order to address this, aerosols samples were collected during and absence of AD incursions during the summer of 2017 using a Hi-Volume (Hi-Vol) sampler for total suspended particles (TSP) at two sampling stations in Puerto Rico. The first station is a marine site located at Cabezas de San Juan (CSJ) Nature Reserve in Fajardo, and the second station is an urban site located at the Facundo Bueso (FB) building at the University of Puerto Rico-Rio Piedras. Aerosol samples were collected using Whatman 41 grade filters from which we determined the concentration of dust particles and the water-soluble ions (e.g., Na+, NH4+, Ca+2, Cl-, SO4-2) in the presence and absence of LRTAD particles. Saharan Air Layer (SAL) imagery, the results from the air mass backward trajectories calculated with the NOAA Hybrid Single Particle Lagrangian Integrated Trajectory Model (HYSPLIT), and the spectral coefficients from measurements at CSJ were used to monitor and confirm the presence of air masses coming from North Africa. Average dust concentrations using the Stacked-Filter Units (SFUs) at CSJ are around 4 μg/m3. LRTAD concentrations and ionic speciation results using the Hi-Vol for the marine and urban sites will be presented at the conference.

  6. Ecological relationships between xerophilic fungi and house-dust mites (Acarida: Pyroglyphidae).

    Science.gov (United States)

    Lustgraaf, B V D

    1978-01-01

    At. 75 and 80% relative humidity (RH), on a wheat germ flake medium, Aspergillus penicilloides grew abundantly and suppressed the population growth of Dermatophagoides pteronyssiunus. At 71% RH, A. penicilloides grew moderately and was only antagonistic to D. pteronyssinus when the fungus was previously incubated on the medium.On a human dander medium and on mattress dust, A. penicilloides grew moderately at 71% and 75% RH and stimulated the development of D. pteronyssinus populations. Also a moderate growth of Eurotium repens on human dander positively influenced D. pteronyssinus. Wallemia sebi and Penicillium brevicompactum grew slightly or did not grow at all at 75% RH. No effect was observed on D. pteronyssinus.It appears that xerophilic fungi may stimulate, and occasionally may reduce, the growth of house-dust mite populations in the natural environment.

  7. Acaricidal activity of Cymbopogon citratus and Azadirachta indica against house dust mites.

    Science.gov (United States)

    Hanifah, Azima Laili; Awang, Siti Hazar; Ming, Ho Tze; Abidin, Suhaili Zainal; Omar, Maizatul Hashima

    2011-10-01

    To examine the acaricidal effects of the essential oil of Cymbopogon citratus leaf extract (lemongrass) and ethanolic Azadirachta indica leaf extract (neem) against house dust mites Dermatophagoides farinae (D. farinae) and Dermatophagoides pteronyssinus (D. pteronyssinus). Twenty-five adults mites were placed onto treated filter paper that is soaked with plant extract and been tested at different concentrations (50.00%, 25.00%, 12.50%, 6.25% and 3.13%) and exposure times (24hrs, 48hrs, 72hrs and 96 hrs). All treatments were replicated 7 times, and the experiment repeated once. The topical and contact activities of the two herbs were investigated. Mortalities from lemongrass extract were higher than neem for both topical and contact activities. At 50 % concentration, both 24 hrs topical and contact exposures to lemongrass resulted in more than 91% mortalities for both species of mites. At the same concentration and exposure time, neem resulted in topical mortalities of 40.3% and 15.7% against D. pteronyssinus and D. farinae respectively; contact mortalities were 8.0% and 8.9% against the 2 mites, respectively. There was no difference in topical mortalities of D. pteronyssinus from exposure to concentrations of lemongrass and neem up to 12.50%; lemongrass was more effective than neem at the higher concentrations. Generally, topical mortalities of D. farinae due to lemongrass are higher than that due to neem. Contact mortalities of lemongrass are always higher that neem against both species of mites.

  8. Using house dust extracts to understand the immunostimulatory activities of living environments.

    Science.gov (United States)

    Batzer, Glenda; Lam, Diane P; Paulus, Petra; Boasen, Jared; Ng, Nicholas; Horner, Anthony A

    2007-01-01

    Laboratory and epidemiological studies have provided indirect but compelling evidence that toll-like receptor (TLR) signaling pathways play an important role in host responsiveness to ambient immunostimulatory factors. Nonetheless, direct evidence is limited. This paper will present our experience investigating the innate immunostimulatory activities of sterile house dust extracts (HDEs). In initial studies, bone marrow derived dendritic cells (BMDDCs) were cultured with HDEs, and cytokine production and co-stimulatory molecule expression were evaluated. In additional experiments, the TLR dependence of these responses was determined. HDEs induced concentration-dependent BMDDC activation. Moreover, the relative bioactivities of HDEs correlated with their endotoxin content. Finally, HDE-mediated responses were found to be partially dependent on TLR2, TLR4, and TLR9 and almost completely dependent on MyD88. These investigations provide the first direct evidence that TLR signaling pathways play a key role in innate responsiveness to non-infectious factors ubiquitous in living environments.

  9. Asthma, Airway Symptoms and Rhinitis in Office Workers in Malaysia: Associations with House Dust Mite (HDM Allergy, Cat Allergy and Levels of House Dust Mite Allergens in Office Dust.

    Directory of Open Access Journals (Sweden)

    Fang Lee Lim

    Full Text Available A prevalence study was conducted among office workers in Malaysia (N= 695. The aim of this study was to examine associations between asthma, airway symptoms, rhinitis and house dust mites (HDM and cat allergy and HDM levels in office dust. Medical data was collected by a questionnaire. Skin prick tests were performed for HDM allergens (Dermatophagoides pteronyssinus, Dermatophagoides farinae and cat allergen Felis domesticus. Indoor temperature and relative air humidity (RH were measured in the offices and vacuumed dust samples were analyzed for HDM allergens. The prevalence of D. pteronyssinus, D. farinae and cat allergy were 50.3%, 49.0% and 25.5% respectively. Totally 9.6% had doctor-diagnosed asthma, 15.5% had current wheeze and 53.0% had current rhinitis. The Der p 1 (from D. pteronyssinus and Der f 1 (from D. farinae allergens levels in dust were 556 ng/g and 658 ng/g respectively. Statistical analysis was conducted by multilevel logistic regression, adjusting for age, gender, current smoking, HDM or cat allergy, home dampness and recent indoor painting at home. Office workers with HDM allergy had more wheeze (p= 0.035, any airway symptoms (p= 0.032, doctor-diagnosed asthma (p= 0.005, current asthma (p= 0.007, current rhinitis (p= 0.021 and rhinoconjuctivitis (p< 0.001. Cat allergy was associated with wheeze (p= 0.021, wheeze when not having a cold (p= 0.033, any airway symptoms (p= 0.034, doctor-diagnosed asthma (p= 0.010, current asthma (p= 0.020 and nasal allergy medication (p= 0.042. Der f 1 level in dust was associated with daytime breathlessness (p= 0.033 especially among those with HDM allergy. Der f 1 levels were correlated with indoor temperature (p< 0.001 and inversely correlated with RH (p< 0.001. In conclusion, HDM and cat allergies were common and independently associated with asthma, airway symptoms and rhinitis. Der f 1 allergen can be a risk factor for daytime breathlessness.

  10. Using house dust extracts to understand the immunostimulatory activities of living environments

    OpenAIRE

    Batzer, Glenda; Lam, Diane P.; Paulus, Petra; Boasen, Jared; Ng, Nicholas; Horner, Anthony A.

    2007-01-01

    Laboratory and epidemiological studies have provided indirect but compelling evidence that toll like receptor (TLR) signaling pathways play an important role in host responsiveness to ambient immunostimulatory factors. Nonetheless, direct evidence is limited. This review will present our experience investigating the innate immunostimulatory activities of sterile house dust extracts (HDEs). In initial studies, bone marrow derived dendritic cells (BMDDCs) were cultured with HDEs and cytokine pr...

  11. Impact of cement dust on the mineral and energy concentration of Psidium guayava

    Energy Technology Data Exchange (ETDEWEB)

    Lai, B.; Ambasht, R.S.

    1982-12-01

    The impact of cement dust deposition on mineral and energy concentration of leaves of guava Psidium guayava growing in the vicinity of Churk Dement Factory situated at Churk, District-Mirzapur (India) was studied. Concentrations of calcium (Ca), potassium (K), sodium (Na) and phosphorus (P) were increased while energy content (cal g/sup -1/ dry weight) was reduced (12.3%) more in cement-dust-covered leaves than in dust-free leaves of Psidium guayava. Statistically it was found that the difference in the concentration of Ca, K, and P industry and dust-free leaves was highly correlated and significant with the amount of cement dust deposited (gm/sup -2/ leaf surface) on the leaf surface of P. guayava while the difference in the concentration of Na--although positively correlated--is not significant. Maximum values of concentrations of Ca, K, Na, P and energy were 5.20%, 0.48%, 0.025%, 0.15% and 4936.7 cal g/sup -1/ dry weight in dust-covered leaves and 3.50%, 0.30%, 0.018%, 0.12% and 5301.4 cal g/sup -1/ dry weight in dust-free leaves, respectively.

  12. Product screening for sources of halogenated flame retardants in Canadian house and office dust

    Energy Technology Data Exchange (ETDEWEB)

    Abbasi, Golnoush [Department of Geography, University of Toronto, 100 St. George St., Toronto M5S 3G3 (Canada); Saini, Amandeep [Department of Physical and Environmental Sciences, University of Toronto, 1265 Military Trail, Toronto M1C 1A4 (Canada); Goosey, Emma [Department of Earth Sciences, University of Toronto, 22 Russell Street, Toronto M5S 3B1 (Canada); Diamond, Miriam L., E-mail: miriam.diamond@utoronto.ca [Department of Earth Sciences, University of Toronto, 22 Russell Street, Toronto M5S 3B1 (Canada); Department of Physical and Environmental Sciences, University of Toronto, 1265 Military Trail, Toronto M1C 1A4 (Canada)

    2016-03-01

    Human exposure to halogenated flame retardants (HFRs) such as polybrominated diphenyl ethers (PBDEs) and their replacements, can be related to exposure to indoor dust and direct contact with HFR-containing products. This study aimed to identify electronic products that contributed to HFRs measured in indoor dust and to develop a screening method for identifying HFRs in hard polymer products. Concentrations of 10 PBDEs and 12 halogenated replacements in dust and surface wipe samples of hard polymer casings of electronic products plus Br in the surfaces of those casing measured using X-ray fluorescence (XRF) were analyzed from 35 homes and 10 offices in Toronto (ON, Canada). HFR concentrations in dust and product wipes were positively correlated. Thus, we hypothesize that electronic products with the highest HFR concentrations contribute the most to concentrations in dust, regardless of the volatility of the HFR. Abundant HFRs in dust and product wipes were PBDEs (BDE-47, 99, 100, 153, 154, 183, 209), TDCPP, DBDPE, EH-TBB and BEHTBP. Older CRT TVs had the highest concentration of BDE-209 of all products tested. This was followed by higher concentrations of HFRs in PCs, Audio/Video (A/V) devices, small household appliances (HHAs) and flat screen TVs. The removal of HFRs from polymer surfaces using wipes supports concerns that HFRs could be transferred from these surfaces to hands as a result of direct contact with HFR-containing products. Surface wipe testing shows promise for screening additive HFRs. In comparison, the Br-content obtained using a handheld XRF analyzer did not correspond to concentrations obtained from surface wipe testing. - Highlights: • Concentrations of flame retardants in dust correlated with product surface wipes • Most abundant FRs in electronics were PBDEs, TDCPP, DBDPE, EH-TBB and BEHTBP. • Descending order of FRs in CRTs, TVs, PCs, A-V devices, and small household appliances • Product wipe testing, but not XRF, useful for non

  13. Product screening for sources of halogenated flame retardants in Canadian house and office dust

    International Nuclear Information System (INIS)

    Abbasi, Golnoush; Saini, Amandeep; Goosey, Emma; Diamond, Miriam L.

    2016-01-01

    Human exposure to halogenated flame retardants (HFRs) such as polybrominated diphenyl ethers (PBDEs) and their replacements, can be related to exposure to indoor dust and direct contact with HFR-containing products. This study aimed to identify electronic products that contributed to HFRs measured in indoor dust and to develop a screening method for identifying HFRs in hard polymer products. Concentrations of 10 PBDEs and 12 halogenated replacements in dust and surface wipe samples of hard polymer casings of electronic products plus Br in the surfaces of those casing measured using X-ray fluorescence (XRF) were analyzed from 35 homes and 10 offices in Toronto (ON, Canada). HFR concentrations in dust and product wipes were positively correlated. Thus, we hypothesize that electronic products with the highest HFR concentrations contribute the most to concentrations in dust, regardless of the volatility of the HFR. Abundant HFRs in dust and product wipes were PBDEs (BDE-47, 99, 100, 153, 154, 183, 209), TDCPP, DBDPE, EH-TBB and BEHTBP. Older CRT TVs had the highest concentration of BDE-209 of all products tested. This was followed by higher concentrations of HFRs in PCs, Audio/Video (A/V) devices, small household appliances (HHAs) and flat screen TVs. The removal of HFRs from polymer surfaces using wipes supports concerns that HFRs could be transferred from these surfaces to hands as a result of direct contact with HFR-containing products. Surface wipe testing shows promise for screening additive HFRs. In comparison, the Br-content obtained using a handheld XRF analyzer did not correspond to concentrations obtained from surface wipe testing. - Highlights: • Concentrations of flame retardants in dust correlated with product surface wipes • Most abundant FRs in electronics were PBDEs, TDCPP, DBDPE, EH-TBB and BEHTBP. • Descending order of FRs in CRTs, TVs, PCs, A-V devices, and small household appliances • Product wipe testing, but not XRF, useful for non

  14. HOUSE DUST MITE CONTAMINATION IN HOTELS AND INNS IN BANDAR ABBAS, SOUTH OF IRAN

    Directory of Open Access Journals (Sweden)

    M. Soleimani, J. Rafinejad

    2008-07-01

    Full Text Available House dust mites have been shown to be strongly associated with allergic respiratory diseases such as, bronchial asthma, rhinitis and atopic dermatitis in the world. The climatic conditions of Bandar-Abbas, which is located in a coastal area and has a humid subtropical climate, provide a suitable place to proliferate mites. The aim of this study was to determine the contamination rate and analyze the house dust mite fauna in hotels and inns in Bandar-Abbas that had not been investigated previously. In this study 6 hotels and 6 inns were selected randomly in six areas of Bandar-Abbas. Two dust samples were collected from each place with a vacuum cleaner. One square meter of carpets and mattresses were vacuumed for a period of 1 min. Then the samples were cleared in lactic acid and then mites were mounted in Hoyer's medium for study and identification. A total of 2644 mites were collected and identified. The major mite family was Pyroglyphidae (98%. Dermatophagoides pteronyssinus was the most frequent and most numerous species recorded, occurring in 91% of samples examined and forming 88% of the Pyroglyphidae and 86% of the total mite populations. The family Cheyletidae was less commonly found with Cheyletus malaccensis (2%. Most of the mites were isolated from the carpets (57.5%, and a smaller number from mattresses (42.5%. Mites were present in 96% of the dust samples. Results revealed that all inns and 83% of hotels were contaminated by more than one species of mite and 34% of them had a population of more than 100 mites /g dust. This rate of contamination can be a major risk factor in asthma and other respiratory allergic diseases

  15. Particle size fractionation and human exposure of polybrominated diphenyl ethers in indoor dust from Chicago.

    Science.gov (United States)

    Wei, Hua; Turyk, Mary; Cali, Salvatore; Dorevitch, Samuel; Erdal, Serap; Li, An

    2009-11-01

    The objective of this study was to investigate the concentration level, the mass distribution based on dust particle size, and the associated human exposure of polybrominated diphenyl ethers (PBDEs) in indoor dust. The total concentration of 13 PBDEs Sigma(13)(BDEs) was found to be 500-6,944 ng/g in indoor dusts, 4,000 ng/g in car interior dust, 260-300 ng/g in outdoor ambient air particles, 30 ng/g in carpet fibers, and as high as 0.5% in carpet padding. Selected dust samples were fractionated based on particle size, and over 80% of the Sigma(13)BDEs were associated with particles exposure of Americans to PBDEs via hand-to-mouth transfer of house dust was estimated under the central tendency exposure and reasonable maximum exposure scenarios. The results suggest that ingestion of PBDE-laden house dust via hand-to-mouth contact is likely a significant exposure pathway, especially for children.

  16. Effect of wind speed and relative humidity on atmospheric dust concentrations in semi-arid climates.

    Science.gov (United States)

    Csavina, Janae; Field, Jason; Félix, Omar; Corral-Avitia, Alba Y; Sáez, A Eduardo; Betterton, Eric A

    2014-07-15

    Atmospheric particulate have deleterious impacts on human health. Predicting dust and aerosol emission and transport would be helpful to reduce harmful impacts but, despite numerous studies, prediction of dust events and contaminant transport in dust remains challenging. In this work, we show that relative humidity and wind speed are both determinants in atmospheric dust concentration. Observations of atmospheric dust concentrations in Green Valley, AZ, USA, and Juárez, Chihuahua, México, show that PM10 concentrations are not directly correlated with wind speed or relative humidity separately. However, selecting the data for high wind speeds (>4m/s at 10 m elevation), a definite trend is observed between dust concentration and relative humidity: dust concentration increases with relative humidity, reaching a maximum around 25% and it subsequently decreases with relative humidity. Models for dust storm forecasting may be improved by utilizing atmospheric humidity and wind speed as main drivers for dust generation and transport. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Human apolipoprotein E genotypes differentially modify house dust mite-induced airway disease in mice

    DEFF Research Database (Denmark)

    Yao, Xianglan; Dai, Cuilian; Fredriksson, Karin

    2012-01-01

    Apolipoprotein E (apoE) is an endogenous negative regulator of airway hyperreactivity (AHR) and mucous cell metaplasia in experimental models of house dust mite (HDM)-induced airway disease. The gene encoding human apoE is polymorphic, with three common alleles (e2, e3, and e4) reflecting single ...

  18. Associations between bacterial communities of house dust and infant gut

    Energy Technology Data Exchange (ETDEWEB)

    Konya, T.; Koster, B. [Division of Occupational and Environmental Health, Dalla Lana School of Public Health, University of Toronto (Canada); Maughan, H. [Department of Cell and Systems Biology, University of Toronto (Canada); Escobar, M. [Division of Occupational and Environmental Health, Dalla Lana School of Public Health, University of Toronto (Canada); Azad, M. B. [Department of Pediatrics, University of Alberta (Canada); Guttman, D. S. [Department of Cell and Systems Biology, University of Toronto (Canada); Sears, M. R. [Department of Medicine, McMaster University (Canada); Becker, A. B. [University of Manitoba (Canada); Brook, J. R. [Division of Occupational and Environmental Health, Dalla Lana School of Public Health, University of Toronto (Canada); Environment Canada (Canada); Takaro, T. K. [Faculty of Health Science, Simon Fraser University (Canada); Kozyrskyj, A. L. [Department of Pediatrics, University of Alberta (Canada); Scott, J.A., E-mail: james.scott@utoronto.ca [Division of Occupational and Environmental Health, Dalla Lana School of Public Health, University of Toronto (Canada)

    2014-05-01

    The human gut is host to a diverse and abundant community of bacteria that influence health and disease susceptibility. This community develops in infancy, and its composition is strongly influenced by environmental factors, notably perinatal anthropogenic exposures such as delivery mode (Cesarean vs. vaginal) and feeding method (breast vs. formula); however, the built environment as a possible source of exposure has not been considered. Here we report on a preliminary investigation of the associations between bacteria in house dust and the nascent fecal microbiota from 20 subjects from the Canadian Healthy Infant Longitudinal Development (CHILD) Study using high-throughput sequence analysis of portions of the 16S rRNA gene. Despite significant differences between the dust and fecal microbiota revealed by Nonmetric Multidimensional Scaling (NMDS) analysis, permutation analysis confirmed that 14 bacterial OTUs representing the classes Actinobacteria (3), Bacilli (3), Clostridia (6) and Gammaproteobacteria (2) co-occurred at a significantly higher frequency in matched dust–stool pairs than in randomly permuted pairs, indicating an association between these dust and stool communities. These associations could indicate a role for the indoor environment in shaping the nascent gut microbiota, but future studies will be needed to confirm that our findings do not solely reflect a reverse pathway. Although pet ownership was strongly associated with the presence of certain genera in the dust for dogs (Agrococcus, Carnobacterium, Exiguobacterium, Herbaspirillum, Leifsonia and Neisseria) and cats (Escherichia), no clear patterns were observed in the NMDS-resolved stool community profiles as a function of pet ownership.

  19. Associations between bacterial communities of house dust and infant gut

    International Nuclear Information System (INIS)

    Konya, T.; Koster, B.; Maughan, H.; Escobar, M.; Azad, M.B.; Guttman, D.S.; Sears, M.R.; Becker, A.B.; Brook, J.R.; Takaro, T.K.; Kozyrskyj, A.L.; Scott, J.A.

    2014-01-01

    The human gut is host to a diverse and abundant community of bacteria that influence health and disease susceptibility. This community develops in infancy, and its composition is strongly influenced by environmental factors, notably perinatal anthropogenic exposures such as delivery mode (Cesarean vs. vaginal) and feeding method (breast vs. formula); however, the built environment as a possible source of exposure has not been considered. Here we report on a preliminary investigation of the associations between bacteria in house dust and the nascent fecal microbiota from 20 subjects from the Canadian Healthy Infant Longitudinal Development (CHILD) Study using high-throughput sequence analysis of portions of the 16S rRNA gene. Despite significant differences between the dust and fecal microbiota revealed by Nonmetric Multidimensional Scaling (NMDS) analysis, permutation analysis confirmed that 14 bacterial OTUs representing the classes Actinobacteria (3), Bacilli (3), Clostridia (6) and Gammaproteobacteria (2) co-occurred at a significantly higher frequency in matched dust–stool pairs than in randomly permuted pairs, indicating an association between these dust and stool communities. These associations could indicate a role for the indoor environment in shaping the nascent gut microbiota, but future studies will be needed to confirm that our findings do not solely reflect a reverse pathway. Although pet ownership was strongly associated with the presence of certain genera in the dust for dogs (Agrococcus, Carnobacterium, Exiguobacterium, Herbaspirillum, Leifsonia and Neisseria) and cats (Escherichia), no clear patterns were observed in the NMDS-resolved stool community profiles as a function of pet ownership

  20. Elemental concentrations in deposited dust on leaves along an urbanization gradient.

    Science.gov (United States)

    Simon, Edina; Baranyai, Edina; Braun, Mihály; Cserháti, Csaba; Fábián, István; Tóthmérész, Béla

    2014-08-15

    Environmental health is an essential component of the quality of life in modern societies. Monitoring of environmental quality and the assessment of environmental risks are often species based on the elemental concentration of deposited dust. Our result suggested that stomata size and distribution were the most important factors influencing the accumulation of air contaminants in leaves. We found that the leaves' surfaces of Acer negundo and Celtis occidentalis were covered by a large number of trichomes, and these species have proven to be suitable biomonitors for atmospheric pollution difficult; these can be overcome using bioindicator species. Leaves of Padus serotina, Acer campestre, A. negundo, Quercus robur and C. occidentalis were used to assess the amount of deposited dust and the concentration of contaminants in deposited dust in and around the city of Debrecen, Hungary. Samples were collected from an urban, suburban and rural area along an urbanization gradient. The concentrations of Ba, Cu, Fe, Mn, Ni, Pb, S, Sr and Zn were determined in deposited dust using ICP-OES. Scanning electron microscopy (SEM) was used to explore the morphological structure and dust absorbing capacity of leaves. We found significant differences in dust deposition among species, and dust deposition correlated with trichomes' density. Principal component analysis (PCA) also showed a total separation of tree. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Elemental concentrations in deposited dust on leaves along an urbanization gradient

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Edina, E-mail: edina.simon@gmail.com [Department of Ecology, University of Debrecen, H-4010 Debrecen, P.O. Box 71 (Hungary); Baranyai, Edina [Department of Inorganic and Analytical Chemistry, University of Debrecen, H-4010 Debrecen, P.O. Box 21 (Hungary); Agilent Atomic Spectroscopy Partner Laboratory, University of Debrecen, Egyetem tér 1, H-4032 Debrecen (Hungary); Braun, Mihály [Institute of Nuclear Research of the Hungarian Academy of Sciences, Herteleni Laboratory of Environmental Studies, 4026 Debrecen, Bem tér 18/C (Hungary); Cserháti, Csaba [Department of Solid State Physics, University of Debrecen, H-4010 Debrecen, P.O. Box 2 (Hungary); Fábián, István [Department of Inorganic and Analytical Chemistry, University of Debrecen, H-4010 Debrecen, P.O. Box 21 (Hungary); Tóthmérész, Béla [HAS-UD Biodiversity and Ecosystem Services Research Group, H-4010 Debrecen, P.O. Box 71 (Hungary)

    2014-08-15

    Environmental health is an essential component of the quality of life in modern societies. Monitoring of environmental quality and the assessment of environmental risks are often species based on the elemental concentration of deposited dust. Our result suggested that stomata size and distribution were the most important factors influencing the accumulation of air contaminants in leaves. We found that the leaves' surfaces of Acer negundo and Celtis occidentalis were covered by a large number of trichomes, and these species have proven to be suitable biomonitors for atmospheric pollution difficult; these can be overcome using bioindicator species. Leaves of Padus serotina, Acer campestre, A. negundo, Quercus robur and C. occidentalis were used to assess the amount of deposited dust and the concentration of contaminants in deposited dust in and around the city of Debrecen, Hungary. Samples were collected from an urban, suburban and rural area along an urbanization gradient. The concentrations of Ba, Cu, Fe, Mn, Ni, Pb, S, Sr and Zn were determined in deposited dust using ICP–OES. Scanning electron microscopy (SEM) was used to explore the morphological structure and dust absorbing capacity of leaves. We found significant differences in dust deposition among species, and dust deposition correlated with trichomes' density. Principal component analysis (PCA) also showed a total separation of tree. - Highlights: • Dust is used as indicators of the accumulation of inorganic pollutants. • Scanning EM was used to explore the morphological structure of leaves. • Amount of dust deposited of leaves correlated with trichomes' density. • A. negundo, C. occidentalis and Q. robur are suitable to indicate air contaminants. • A. negundo and C. occidentalis are suitable to decrease the amount of dust in air.

  2. Elemental concentrations in deposited dust on leaves along an urbanization gradient

    International Nuclear Information System (INIS)

    Simon, Edina; Baranyai, Edina; Braun, Mihály; Cserháti, Csaba; Fábián, István; Tóthmérész, Béla

    2014-01-01

    Environmental health is an essential component of the quality of life in modern societies. Monitoring of environmental quality and the assessment of environmental risks are often species based on the elemental concentration of deposited dust. Our result suggested that stomata size and distribution were the most important factors influencing the accumulation of air contaminants in leaves. We found that the leaves' surfaces of Acer negundo and Celtis occidentalis were covered by a large number of trichomes, and these species have proven to be suitable biomonitors for atmospheric pollution difficult; these can be overcome using bioindicator species. Leaves of Padus serotina, Acer campestre, A. negundo, Quercus robur and C. occidentalis were used to assess the amount of deposited dust and the concentration of contaminants in deposited dust in and around the city of Debrecen, Hungary. Samples were collected from an urban, suburban and rural area along an urbanization gradient. The concentrations of Ba, Cu, Fe, Mn, Ni, Pb, S, Sr and Zn were determined in deposited dust using ICP–OES. Scanning electron microscopy (SEM) was used to explore the morphological structure and dust absorbing capacity of leaves. We found significant differences in dust deposition among species, and dust deposition correlated with trichomes' density. Principal component analysis (PCA) also showed a total separation of tree. - Highlights: • Dust is used as indicators of the accumulation of inorganic pollutants. • Scanning EM was used to explore the morphological structure of leaves. • Amount of dust deposited of leaves correlated with trichomes' density. • A. negundo, C. occidentalis and Q. robur are suitable to indicate air contaminants. • A. negundo and C. occidentalis are suitable to decrease the amount of dust in air

  3. Dependence of indoor radon concentration on the year of house construction

    International Nuclear Information System (INIS)

    Fujimoto, K.; Sanada, T.

    1999-01-01

    The dependence of indoor radon concentration on the year of house construction was studied using the results of two nationwide indoor radon surveys in Japan. The data of radon concentration in the surveys were classified into structure type as well as year of construction to obtain the current radon concentration for each structure type as a function of year of construction. The indoor radon concentration in wooden houses was found to be relatively constant with year of house construction until 1960, and then decreased, whereas the radon concentration in concrete houses increased sharply in houses constructed after 1970. The concentration in concrete houses built before 1975 was almost the same as that in contemporary wooden houses. However, the concentration in concrete houses built at present was about two times higher than that in wooden houses. The time trends found for wooden and concrete houses in the first nationwide indoor radon survey were confirmed by the second nationwide survey. In addition, these same time trends were mostly observed in the data classified into 7 districts in Japan. The increase of indoor radon concentration in concrete houses provides relatively high dose, and this increasing trend seems to continue, judging from the results of two nationwide surveys

  4. Saharan Dust Particle Size And Concentration Distribution In Central Ghana

    Science.gov (United States)

    Sunnu, A. K.

    2010-12-01

    A.K. Sunnu*, G. M. Afeti* and F. Resch+ *Department of Mechanical Engineering, Kwame Nkrumah University of Science and Technology (KNUST) Kumasi, Ghana. E-mail: albertsunnu@yahoo.com +Laboratoire Lepi, ISITV-Université du Sud Toulon-Var, 83162 La Valette cedex, France E-mail: resch@univ-tln.fr Keywords: Atmospheric aerosol; Saharan dust; Particle size distributions; Particle concentrations. Abstract The Saharan dust that is transported and deposited over many countries in the West African atmospheric environment (5°N), every year, during the months of November to March, known locally as the Harmattan season, have been studied over a 13-year period, between 1996 and 2009, using a location at Kumasi in central Ghana (6° 40'N, 1° 34'W) as the reference geographical point. The suspended Saharan dust particles were sampled by an optical particle counter, and the particle size distributions and concentrations were analysed. The counter gives the total dust loads as number of particles per unit volume of air. The optical particle counter used did not discriminate the smoke fractions (due to spontaneous bush fires during the dry season) from the Saharan dust. Within the particle size range measured (0.5 μm-25 μm.), the average inter-annual mean particle diameter, number and mass concentrations during the northern winter months of January and February were determined. The average daily number concentrations ranged from 15 particles/cm3 to 63 particles/cm3 with an average of 31 particles/cm3. The average daily mass concentrations ranged from 122 μg/m3 to 1344 μg/m3 with an average of 532 μg/m3. The measured particle concentrations outside the winter period were consistently less than 10 cm-3. The overall dust mean particle diameter, analyzed from the peak representative Harmattan periods over the 13-year period, ranged from 0.89 μm to 2.43 μm with an average of 1.5 μm ± 0.5. The particle size distributions exhibited the typical distribution pattern for

  5. Method and equipment to determine fine dust concentrations

    International Nuclear Information System (INIS)

    Breuer, H.; Gebhardt, J.; Robock, K.

    1979-01-01

    The measured values for the fine dust concentration are obtained by optical means which where possible agree with the probable deposited quantity of fine dust in the pulmonary alveoli. This is done by receiving the strong radiation produced in dependence of the particle size at an angle of 70 0 to the angle of incidence of the primary beam. The wavelength of the primary radiation is in the region of 1000 to 2000 nm. (RW) [de

  6. Heavy metal concentration of settled surface dust in residential building

    International Nuclear Information System (INIS)

    Nor Aimi abdul Wahab; Fairus Muhamad Darus; Norain Isa; Siti Mariam Sumari; Nur Fatihah Muhamad Hanafi

    2012-01-01

    The concentrations of heavy metals (Cu, Ni, Pb and Zn) in settled surface dust were collected from nine residential buildings in different areas in Seberang Prai Tengah District, Pulau Pinang. The samples of settled surface dust were collected in 1 m 2 area by using a polyethylene brush and placed in the dust pan by sweeping the living room floor most accessible to the occupants. Heavy metals concentrations were determined by using inductively coupled plasma optical emission spectrometer (ICP-OES) after digestion with nitric acid and sulphuric acid. The results show that the range of heavy metals observed in residential buildings at Seberang Prai Tengah were in the range of 2.20-14.00 mg/ kg, 1.50-32.70 mg/ kg, 1.50-76.80 mg/ kg and 14.60-54.40 mg/ kg for Cu, Ni, Pb and Zn respectively. The heavy metal concentration in the investigated areas followed the order: Pb > Zn > Ni > Cu. Statistical analysis indicates significant correlation between all the possible pairs of heavy metal. The results suggest a likely common source for the heavy metal contamination, which could be traced most probably to vehicular emissions, street dust and other related activities. (author)

  7. Dust control for draglines

    Energy Technology Data Exchange (ETDEWEB)

    Grad, P.

    2009-09-15

    Monitoring dust levels inside draglines reveals room for improvement in how filtration systems are used and maintained. The Australian firm BMT conducted a field test program to measure airflow parameters, dust fallout rates and dust concentrations, inside and outside the machine house, on four draglines and one shovel. The study involved computational fluid dynamics (CFD) simulations. The article describes how the tests were made and gives results. It was not possible to say which of the two main filtration systems currently used on Australian draglines - Dynavane or Floseps - performs better. It would appear that more frequent maintenance and cleaning would increase the overall filtration performance and systems could be susceptible to repeat clogging in a short time. 2 figs., 1 photos.

  8. A 12-week DBPC dose-finding study with sublingual monomeric allergoid tablets in house dust mite-allergic patients.

    Science.gov (United States)

    Hüser, C; Dieterich, P; Singh, J; Shah-Hosseini, K; Allekotte, S; Lehmacher, W; Compalati, E; Mösges, R

    2017-01-01

    In sublingual immunotherapy, optimal doses are a key factor for therapeutic outcomes. The aim of this study with tablets containing carbamylated monomeric house dust mite allergoids was to determine the most effective and safe dose. In this double-blind, placebo-controlled dose-finding study, 131 patients with house dust mite-induced allergic rhinoconjunctivitis were randomized to 12-week treatments with 300 UA/day, 1000 UA/day, 2000 UA/day, 3000 UA/day or placebo. Conjunctival provocation tests (CPT) were performed before, during and after treatment. The change in mean allergic severity (primary endpoint), calculated from the severity of the CPT reaction, and the proportion of patients with an improved CPT threshold (secondary endpoint) determined the treatment effect. The mean allergic severity decreased in all groups, including the placebo group. It was lower in all active treatment groups (300 UA/day: 0.14, 1000 UA/day: 0.15, 2000 UA/day: 0.10, 3000 UA/day: 0.15) than in the placebo group (0.30). However, this difference was not statistically significant (P allergoid sublingual tablets is well tolerated and reduces the CPT reaction in house dust mite-allergic patients. © 2016 The Authors. Allergy Published by John Wiley & Sons Ltd.

  9. Sensitivity to House Dust Mites Allergens with Atopic Asthma and Its Relationship with CD14 C(-159T) Polymorphism in Patients of West Bengal, India.

    Science.gov (United States)

    Ghosh, Amlan; Dutta, Shampa; Podder, Sanjoy; Mondal, Priti; Laha, Arghya; Saha, Nimai Chandra; Moitra, Saibal; Saha, Goutam Kumar

    2018-01-10

    India is the home to around 15-20 million asthmatics, and asthma prevalence is increasing in Indian metropolitan area, including Kolkata, West Bengal. Complex interactions of genetic and environmental factors are involved in asthma. Genome-wide search for susceptible loci regulating IgE response (atopy) have identified a candidate gene CD14 which is most important in the context of allergic responses of respiratory system. This study was aimed to investigate the role of house dust and house dust mites in development of bronchial asthma and to explore the possible association of candidate gene CD14 with disease manifestation among Kolkata patient population. Skin-prick test was done among 950 asthmatic patients against 8 aeroallergens, including house dust and house dust mites and total serum IgE and allergen-specific IgE were measured. Polymerase chain reaction-restriction fragment length polymorphism was done in patients and nonasthmatic control (n = 255 in each) to characterize a functional polymorphism, C(-159)T, of CD14, a positional candidate gene for allergy. We identified house dust as the most common aeroallergen sensitizer among atopic patients in Kolkata followed by Dermatophagoides pteronyssinus and Dermatophagoides farinae Hughes (Acari: Pyroglyphidae) mites. Patient's sera contain significantly higher IgE level than that of control. Allergen-specific IgE antibody test revealed that 76.36% patients had specific IgE antibody against D. pteronyssinus mite. There was a significant difference in the distribution of alleles and genotypes for CD14 polymorphism with an increase in disease severity. So, in Kolkata, house dust mite is a common aeroallergen and D. pteronyssinus is predominant among mites. The present study revealed that bronchial asthma has a genetic background. © The Author(s) 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Alternative Flame Retardant, 2,4,6-Tris(2,4,6-tribromophenoxy)-1,3,5-triazine, in an E-waste Recycling Facility and House Dust in North America.

    Science.gov (United States)

    Guo, Jiehong; Stubbings, William A; Romanak, Kevin; Nguyen, Linh V; Jantunen, Liisa; Melymuk, Lisa; Arrandale, Victoria; Diamond, Miriam L; Venier, Marta

    2018-03-20

    A high molecular weight compound, 2,4,6-tris(2,4,6-tribromophenoxy)-1,3,5-triazine (TTBP-TAZ), was detected during the analysis of brominated flame retardants in dust samples collected from an electrical and electronic waste (e-waste) recycling facility in Ontario, Canada. Gas chromatography coupled with both high-resolution and low-resolution mass spectrometry (MS) was used to determine TTBP-TAZ's chemical structure and concentrations. To date, TTBP-TAZ has only been detected in plastic casings of electrical and electronic equipment and house dust from The Netherlands. Here we report on the concentrations of TTBP-TAZ in selected samples from North America: e-waste dust ( n = 7) and air ( n = 4), residential dust ( n = 30), and selected outdoor air ( n = 146), precipitation ( n = 19), sediment ( n = 11) and water ( n = 2) samples from the Great Lakes environment. TTBP-TAZ was detected in all the e-waste dust and air samples, and in 70% of residential dust samples. The median concentrations of TTBP-TAZ in these three types of samples were 5540 ng/g, 5.75 ng/m 3 and 6.76 ng/g, respectively. The flame retardants 2,4,6-tribromophenol, tris(2,3-dibromopropyl) isocyanurate, and 3,3',5,5'-tetrabromobisphenol A bis(2,3-dibromopropyl) ether, BDE-47 and BDE-209 were also measured for comparison. None of these other flame retardants concentrations was significantly correlated with those of TTBP-TAZ in any of the sample types suggesting different sources. TTBP-TAZ was not detected in any of the outdoor environmental samples, which may relate to its application history and physicochemical properties. This is the first report of TTBP-TAZ in North America.

  11. Effect of mattress and pillow encasings on children with asthma and house dust mite allergy

    DEFF Research Database (Denmark)

    Halken, Susanne; Høst, Arne; Niklassen, Ulla

    2003-01-01

    BACKGROUND: House dust mite (HDM) allergy is a frequent cause of allergic asthma in children. Reduction of exposure seems to be the most logical way to treat these patients. OBJECTIVE: Our aim was to investigate whether mattress and pillow encasings resulted in an effective long-term control of H...

  12. A controlled intervention study concerning the effect of intended temperature rise on house dust mite load

    DEFF Research Database (Denmark)

    Sidenius, Kirsten E; Hallas, Thorkil E; Poulsen, Lars K.

    2002-01-01

    In epidemiological studies, increased indoor temperature--producing a lower relative humidity--is associated with low house dust mite (HDM) load. Twenty-eight dwellings were allocated for either intervention (12/15 completed) or control (11/13 completed). In the intervention group, participants w...

  13. Gene-by-environment effect of house dust mite on purinergic receptor P2Y12 (P2RY12) and lung function in children with asthma.

    Science.gov (United States)

    Bunyavanich, S; Boyce, J A; Raby, B A; Weiss, S T

    2012-02-01

    Distinct receptors likely exist for leukotriene (LT)E(4), a potent mediator of airway inflammation. Purinergic receptor P2Y12 is needed for LTE(4)-induced airways inflammation, and P2Y12 antagonism attenuates house dust mite-induced pulmonary eosinophilia in mice. Although experimental data support a role for P2Y12 in airway inflammation, its role in human asthma has never been studied. To test for association between variants in the P2Y12 gene (P2RY12) and lung function in human subjects with asthma, and to examine for gene-by-environment interaction with house dust mite exposure. Nineteen single nucleotide polymorphisms (SNPs) in P2RY12 were genotyped in 422 children with asthma and their parents (n = 1266). Using family based methods, we tested for associations between these SNPs and five lung function measures. We performed haplotype association analyses and tested for gene-by-environment interactions using house dust mite exposure. We used the false discovery rate to account for multiple comparisons. Five SNPs in P2RY12 were associated with multiple lung function measures (P-values 0.006–0.025). Haplotypes in P2RY12 were also associated with lung function (P-values 0.0055–0.046). House dust mite exposure modulated associations between P2RY12 and lung function, with minor allele homozygotes exposed to house dust mite demonstrating worse lung function than those unexposed (significant interaction P-values 0.0028–0.040). The P2RY12 variants were associated with lung function in a large family-based asthma cohort. House dust mite exposure caused significant gene-by-environment effects. Our findings add the first human evidence to experimental data supporting a role for P2Y12 in lung function. P2Y12 could represent a novel target for asthma treatment.

  14. House dust exposure mediates gut microbiome Lactobacillus enrichment and airway immune defense against allergens and virus infection.

    Science.gov (United States)

    Fujimura, Kei E; Demoor, Tine; Rauch, Marcus; Faruqi, Ali A; Jang, Sihyug; Johnson, Christine C; Boushey, Homer A; Zoratti, Edward; Ownby, Dennis; Lukacs, Nicholas W; Lynch, Susan V

    2014-01-14

    Exposure to dogs in early infancy has been shown to reduce the risk of childhood allergic disease development, and dog ownership is associated with a distinct house dust microbial exposure. Here, we demonstrate, using murine models, that exposure of mice to dog-associated house dust protects against ovalbumin or cockroach allergen-mediated airway pathology. Protected animals exhibited significant reduction in the total number of airway T cells, down-regulation of Th2-related airway responses, as well as mucin secretion. Following dog-associated dust exposure, the cecal microbiome of protected animals was extensively restructured with significant enrichment of, amongst others, Lactobacillus johnsonii. Supplementation of wild-type animals with L. johnsonii protected them against both airway allergen challenge or infection with respiratory syncytial virus. L. johnsonii-mediated protection was associated with significant reductions in the total number and proportion of activated CD11c(+)/CD11b(+) and CD11c(+)/CD8(+) cells, as well as significantly reduced airway Th2 cytokine expression. Our results reveal that exposure to dog-associated household dust results in protection against airway allergen challenge and a distinct gastrointestinal microbiome composition. Moreover, the study identifies L. johnsonii as a pivotal species within the gastrointestinal tract capable of influencing adaptive immunity at remote mucosal surfaces in a manner that is protective against a variety of respiratory insults.

  15. Mast cell-deficient kit mice develop house dust mite-induced lung inflammation despite impaired eosinophil recruitment

    NARCIS (Netherlands)

    de Boer, J. Daan; Yang, Jack; van den Boogaard, Florry E.; Hoogendijk, Arie J.; de Beer, Regina; van der Zee, Jaring S.; Roelofs, Joris J. T. H.; van 't Veer, Cornelis; de Vos, Alex F.; van der Poll, Tom

    2014-01-01

    Mast cells are implicated in allergic and innate immune responses in asthma, although their role in models using an allergen relevant for human disease is incompletely understood. House dust mite (HDM) allergy is common in asthma patients. Our aim was to investigate the role of mast cells in

  16. Pollution distribution and health risk assessment of heavy metals in indoor dust in Anhui rural, China.

    Science.gov (United States)

    Lin, Yuesheng; Fang, Fengman; Wang, Fei; Xu, Minglu

    2015-09-01

    Zn, Pb, Cu, Cr, V, Ni, Co, and As concentrations of indoor dust in Anhui rural were determined by inductively coupled plasma-optical emission spectroscopy (ICP-OES). The degrees of metal pollution in indoor dust ranked as follows: Zn > Pb > Cr > Cu > V > Ni > Co > As, on average. The arithmetic means of Zn, Pb, Cu, Cr, V, Ni, Co, and As were 427.17, 348.73, 107.05, 113.68, 52.64, 38.93, 10.29, and 4.46 mg/kg, respectively. These were higher than background values of Anhui soil for Zn, Pb, Cu, Cr, and Ni, especially for Pb with the mean value of 13.21 times the background value. Heavy metal concentrations of indoor dust were different from different rural areas. House type (bungalows or storied house), sweeping frequency, and external environment around the house (such as the road grade) affected heavy metal concentrations in indoor dust. The results of factor analysis and correlation analysis indicated that Cu, Cr, Ni, Zn, and Co concentrations were mainly due to interior paint, metal objects, and building materials. Pb and As concentrations were due to vehicle emissions. V concentration was mainly of natural source. Average daily doses for the exposure pathway of the studied heavy metals decreased in children in the following order: hand-to-mouth ingestion > dermal contact > inhalation. The non-carcinogenic risks of heavy metals ranked as Pb > V > Cr > Cu > Zn > As > Co > Ni, and the carcinogenic risks of metals decreased in the order of Cr > Co > As > Ni. The non-carcinogenic hazard indexes and carcinogenic risks of metals in indoor dust were both lower than the safe values.

  17. Lead Concentration in Primary School Soil-Dust in Nigeria, Africa

    Directory of Open Access Journals (Sweden)

    Ekwumemgbo P. A.

    2013-04-01

    Full Text Available Lead in soil has been recognized as a public health problem, particularly among children. In recent years, attention has been directed to cumulative adverse effects of lead at low levels of intake. Leadcontaminated soil and dust have been identified as important contributors to blood lead levels. This work examines the total concentration of lead in primary school soil-dust in Nigeria. Soil-dusts were collected randomly from six geopolitical areas of Nigeria, digested and analysed for total lead concentration by Atomic Absorption Spectrophotometry. The mean lead concentration in the dry season for the North East (NE, North West (NW, North Central (NC, South South (SS, South East (SE, South West (SW were 131.60 ± 70.98 mg/kg, 108.04 ± 47.33 mg/kg, 72.94 ± 55.45 mg/kg, 66.14 ± 43.9 mg/kg, 45.98 ± 34.60 mg/kg and 67.98 ± 34.89 mg/kg respectively. In the raining season the mean lead concentration were 130.78 ± 70.80 mg/kg, 106.24 ± 47.02 mg/kg, 70.96 ± 55.52 mg/kg, 64.12 ± 48.00 mg/kg, 44.58 ± 28.90 mg/kg, and 66.26 ± 41.87 mg/kg respectively. This analysis is necessary to provide scientific data base for the loading of lead in classroom soil-dust in each zone. The authors recommend measurement and surveillance of lead blood level of the primary school children and a clean-up of both classrooms and the school environment.

  18. Open-label parallel dose tolerability study of three subcutaneous immunotherapy regimens in house dust mite allergic patients

    NARCIS (Netherlands)

    Rieker-Schwienbacher, Juliane; Nell, Marja J.; Diamant, Zuzana; van Ree, Ronald; Distler, Andreas; Boot, Johan D.; Kleine-Tebbe, Jörg

    2013-01-01

    BACKGROUND: The current maintenance dose (10,000 AUeq/monthly) of a subcutaneous allergoid for house dust mite (HDM) immunotherapy has previously shown significant clinical efficacy in patients with HDM induced allergic rhinitis or rhinoconjunctivitis. In order to comply with the 2009 EMA guidelines

  19. Effect of ecological restoration programs on dust concentrations in the North China Plain: a case study

    Science.gov (United States)

    Long, Xin; Tie, Xuexi; Li, Guohui; Cao, Junji; Feng, Tian; Zhao, Shuyu; Xing, Li; An, Zhisheng

    2018-05-01

    In recent decades, the Chinese government has made a great effort in initiating large-scale ecological restoration programs (ERPs) to reduce the dust concentrations in China, especially for dust storm episodes. Using the Moderate Resolution Imaging Spectroradiometer (MODIS) land cover product, the ERP-induced land cover changes are quantitatively evaluated in this study. Two obvious vegetation protective barriers arise throughout China from the southwest to the northeast, which are well known as the Green Great Wall (GGW). Both the grass GGW and forest GGW are located between the dust source region (DSR) and the densely populated North China Plain (NCP). To assess the effect of ERPs on dust concentrations, a regional transport/dust model (WRF-DUST, Weather Research and Forecast model with dust) is applied to investigate the evolution of dust plumes during a strong dust storm episode from 2 to 8 March 2016. The WRF-DUST model generally performs reasonably well in reproducing the temporal variations and spatial distributions of near-surface [PMC] (mass concentration of particulate matter with aerodynamic diameter between 2.5 and 10 µm) during the dust storm event. Sensitivity experiments have indicated that the ERP-induced GGWs help to reduce the dust concentration in the NCP, especially in BTH (Beijing, Tianjin, and Hebei). When the dust storm is transported from the upwind DSR to the downwind NCP, the [PMC] reduction ranges from -5 to -15 % in the NCP, with a maximum reduction of -12.4 % (-19.2 µg m-3) in BTH and -7.6 % (-10.1 µg m-3) in the NCP. We find the dust plumes move up to the upper atmosphere and are transported from the upwind DSR to the downwind NCP, accompanied by dust decrease. During the episode, the forest GGW is nonsignificant in dust concentration control because it is of benefit for dry deposition and not for emission. Conversely, the grass GGW is beneficial in controlling dust erosion and is the dominant reason for [PMC] decrease in the NCP

  20. Effect of ecological restoration programs on dust concentrations in the North China Plain: a case study

    Directory of Open Access Journals (Sweden)

    X. Long

    2018-05-01

    Full Text Available In recent decades, the Chinese government has made a great effort in initiating large-scale ecological restoration programs (ERPs to reduce the dust concentrations in China, especially for dust storm episodes. Using the Moderate Resolution Imaging Spectroradiometer (MODIS land cover product, the ERP-induced land cover changes are quantitatively evaluated in this study. Two obvious vegetation protective barriers arise throughout China from the southwest to the northeast, which are well known as the Green Great Wall (GGW. Both the grass GGW and forest GGW are located between the dust source region (DSR and the densely populated North China Plain (NCP. To assess the effect of ERPs on dust concentrations, a regional transport/dust model (WRF-DUST, Weather Research and Forecast model with dust is applied to investigate the evolution of dust plumes during a strong dust storm episode from 2 to 8 March 2016. The WRF-DUST model generally performs reasonably well in reproducing the temporal variations and spatial distributions of near-surface [PMC] (mass concentration of particulate matter with aerodynamic diameter between 2.5 and 10 µm during the dust storm event. Sensitivity experiments have indicated that the ERP-induced GGWs help to reduce the dust concentration in the NCP, especially in BTH (Beijing, Tianjin, and Hebei. When the dust storm is transported from the upwind DSR to the downwind NCP, the [PMC] reduction ranges from −5 to −15 % in the NCP, with a maximum reduction of −12.4 % (−19.2 µg m−3 in BTH and −7.6 % (−10.1 µg m−3 in the NCP. We find the dust plumes move up to the upper atmosphere and are transported from the upwind DSR to the downwind NCP, accompanied by dust decrease. During the episode, the forest GGW is nonsignificant in dust concentration control because it is of benefit for dry deposition and not for emission. Conversely, the grass GGW is beneficial in controlling dust erosion and is the

  1. Investigating the size, shape and surface roughness dependence of polarization lidars with light-scattering computations on real mineral dust particles: Application to dust particles' external mixtures and dust mass concentration retrievals

    Science.gov (United States)

    Mehri, Tahar; Kemppinen, Osku; David, Grégory; Lindqvist, Hannakaisa; Tyynelä, Jani; Nousiainen, Timo; Rairoux, Patrick; Miffre, Alain

    2018-05-01

    Our understanding of the contribution of mineral dust to the Earth's radiative budget is limited by the complexity of these particles, which present a wide range of sizes, are highly-irregularly shaped, and are present in the atmosphere in the form of particle mixtures. To address the spatial distribution of mineral dust and atmospheric dust mass concentrations, polarization lidars are nowadays frequently used, with partitioning algorithms allowing to discern the contribution of mineral dust in two or three-component particle external mixtures. In this paper, we investigate the dependence of the retrieved dust backscattering (βd) vertical profiles with the dust particle size and shape. For that, new light-scattering numerical simulations are performed on real atmospheric mineral dust particles, having determined mineralogy (CAL, DOL, AGG, SIL), derived from stereogrammetry (stereo-particles), with potential surface roughness, which are compared to the widely-used spheroidal mathematical shape model. For each dust shape model (smooth stereo-particles, rough stereo-particles, spheroids), the dust depolarization, backscattering Ångström exponent, lidar ratio are computed for two size distributions representative of mineral dust after long-range transport. As an output, two Saharan dust outbreaks involving mineral dust in two, then three-component particle mixtures are studied with Lyon (France) UV-VIS polarization lidar. If the dust size matters most, under certain circumstances, βd can vary by approximately 67% when real dust stereo-particles are used instead of spheroids, corresponding to variations in the dust backscattering coefficient as large as 2 Mm- 1·sr- 1. Moreover, the influence of surface roughness in polarization lidar retrievals is for the first time discussed. Finally, dust mass-extinction conversion factors (ηd) are evaluated for each assigned shape model and dust mass concentrations are retrieved from polarization lidar measurements. From

  2. African Dust Transport Captured by Rare Earth Elemental Concentrations in Coral Microatolls

    Science.gov (United States)

    Ouellette, G., Jr.; DeLong, K.; Herrmann, A.; Huang, C. Y.; Shen, C. C.

    2017-12-01

    Winds are integral components of the climate system; unfortunately, windsare also among the climate variables that are most difficult to study prior to the instrumentalrecord. Paleoclimatologists use sedimentary dust records (e.g., lake and ocean cores) tounderstand past wind circulation conditions; however, these types of records typically are notamenable to sub-annual interpretation due to their limited temporal resolution. Here wedeveloped a coral-based dust-wind proxy to overcome these temporal limitations by usingtrace (nmol/mol) rare earth elemental concentrations recorded in the skeletons of coralmicroatolls. The rare earth elements (REE; the lanthanides as well as scandium and yttrium)behave similarly in geologic and geochemical systems, and have served as useful proxies ofgeological processes in both deep and shallow time. Corals incorporate REE as they deposittheir exoskeletons that extend incrementally with time forming annual density band couplets.Coral microatolls grow at or near the sea surface, where coral REE concentrations are mostsensitive to dust deposition. Our study site off the west coast of Haiti is down stream of light-REE depleted bedrock whereas REE in African dust, transported by the easterly trade winds,reflect average crustal abundances. This unique "upstream" source signature allows forterrestrial contamination of the dust-wind signal to be ruled out. Light REE concentrations (esp.Nd and Pr) demonstrate an order of magnitude increase within coral aragonite coincident withmajor African dust plume events throughout the past decade, with Nd/Ca and Pr/Ca increasingfrom an average of 27 nmol/mol to an average 144 nmol/mol and an average of 5 nmol/mol toan average of 37 nmol/mol, respectively, during major African dust plume events. Monthly-resolved REE analysis shows these REE peaks coincide with the summer dust season rather thanHaiti's two wet seasons in spring and autumn. Regression of our coral REE dust proxy tosatellite records of

  3. Der p 11 Is a Major Allergen for House Dust Mite-Allergic Patients Suffering from Atopic Dermatitis

    Czech Academy of Sciences Publication Activity Database

    Banerjee, S.; Resch, Y.; Chen, K. W.; Swoboda, I.; Focke-Tejkl, M.; Blatt, K.; Novak, N.; Wickman, M.; van Hage, M.; Ferrara, R.; Mari, A.; Purohit, A.; Pauli, G.; Sibanda, E. N.; Ndlovu, P.; Thomas, W. R.; Krzyžánek, Vladislav; Tacke, S.; Malkus, U.; Valent, P.; Valenta, R.; Vrtala, S.

    2015-01-01

    Roč. 135, č. 1 (2015), s. 102-109 ISSN 0022-202X R&D Projects: GA MŠk(CZ) LO1212 Institutional support: RVO:68081731 Keywords : allergen * house dust mites * immunogold electron microscopy Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 6.915, year: 2015

  4. ADAM10 mediates the house dust mite-induced release of chemokine ligand CCL20 by airway epithelium

    NARCIS (Netherlands)

    Post, S.; Rozeveld, D.; Jonker, M. R.; Bischoff, R.; van Oosterhout, A. J.; Heijink, I. H.

    2015-01-01

    Background: House dust mite (HDM) acts on the airway epithelium to induce airway inflammation in asthma. We previously showed that the ability of HDM to induce allergic sensitization in mice is related to airway epithelial CCL20 secretion. Objective: As a disintegrin and metalloprotease (ADAM)s have

  5. Efficacy and safety of sublingual tablets of house dust mite allergen extracts in adults with allergic rhinitis

    NARCIS (Netherlands)

    Bergmann, Karl-Christian; Demoly, Pascal; Worm, Margitta; Fokkens, Wytske J.; Carrillo, Teresa; Tabar, Ana I.; Nguyen, Hélène; Montagut, Armelle; Zeldin, Robert K.

    2014-01-01

    Preliminary studies have suggested the efficacy of sublingual tablets of house dust mite (HDM) extracts in adults with allergic rhinitis. We sought to assess the efficacy and safety of 2 doses of HDM sublingual tablets over 1 treatment year and the subsequent immunotherapy-free year. Adults with

  6. The evaluation and quantification of respirable coal and silica dust concentrations: a task-based approach.

    Science.gov (United States)

    Grové, T; Van Dyk, T; Franken, A; Du Plessis, J

    2014-01-01

    Silicosis and coal worker's pneumoconiosis are serious occupational respiratory diseases associated with the coal mining industry and the inhalation of respirable dusts containing crystalline silica. The purpose of this study (funded by the Mine Health and Safety Council of South Africa) was to evaluate the individual contributions of underground coal mining tasks to the respirable dust and respirable silica dust concentrations in an underground section by sampling the respirable dust concentrations at the intake and return of each task. The identified tasks were continuous miner (CM) cutting, construction, transfer of coal, tipping, and roof bolting. The respirable dust-generating hierarchy of the tasks from highest to lowest was: transfer of coal > CM right cutting > CM left cutting > CM face cutting > construction > roof bolting > tipping; and for respirable silica dust: CM left cutting > construction > transfer of coal > CM right cutting. Personal exposure levels were determined by sampling the exposures of workers performing tasks in the section. Respirable dust concentrations and low concentrations of respirable silica dust were found at the intake air side of the section, indicating that air entering the section is already contaminated. The hierarchy for personal respirable dust exposures was as follows, from highest to lowest: CM operator > cable handler > miner > roof bolt operator > shuttle car operator, and for respirable silica dust: shuttle car operator > CM operator > cable handler > roof bolt operator > miner. Dust control methods to lower exposures should include revision of the position of workers with regard to the task performed, positioning of the tasks with regard to the CM cutting, and proper use of the line curtains to direct ventilation appropriately. The correct use of respiratory protection should also be encouraged.

  7. SQ house dust mite sublingually administered immunotherapy tablet (ALK) improves allergic rhinitis in patients with house dust mite allergic asthma and rhinitis symptoms

    DEFF Research Database (Denmark)

    Mosbech, Holger; Canonica, G Walter; Backer, Vibeke

    2015-01-01

    BACKGROUND: House dust mite (HDM) allergy is associated with persistent allergic rhinitis (AR) and allergic asthma. OBJECTIVE: To investigate the efficacy and safety of a SQ HDM sublingually administered immunotherapy tablet (ALK, Hørsholm, Denmark) in adults and adolescents with HDM respiratory...... allergic disease and report the AR results. METHODS: Six hundred four subjects at least 14 years old with HDM AR and mild to moderate HDM allergic asthma were randomized 1:1:1:1 to double-blinded daily treatment with 1, 3, 6 SQ-HDM or placebo. End-of-treatment rhinoconjunctivitis symptoms and medication...... score were predefined extrapulmonary end points. A subgroup analysis was conducted post hoc in subjects with a total combined rhinitis score (TCRS) > 0 (ie, with AR symptoms and/or AR medication use during the 4-week baseline period). The subgroup was comprised of 498 subjects (82%). RESULTS...

  8. Radionuclides in house dust

    CERN Document Server

    Fry, F A; Green, N; Hammond, D J

    1985-01-01

    Discharges of radionuclides from the British Nuclear Fuel plc (BNFL) reprocessing plant at Sellafield in Cumbria have led to elevated concentrations radionuclides in the local environment. The major routes of exposure of the public are kept under review by the appropriate Government departments and monitoring is carried out both by the departments and by BNFL itself. Recently, there has been increasing public concern about general environmental contamination resulting from the discharges and, in particular, about possible exposure of members of the public by routes not previously investigated in detail. One such postulated route of exposure that has attracted the interest of the public, the press and Parliament arises from the presence of radionuclides within houses. In view of this obvious and widespread concern, the Board has undertaken a sampling programme in a few communities in Cumbria to assess the radiological significance of this source of exposure. From the results of our study, we conclude that, alt...

  9. Long-term measurement of radon concentration in the family house

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.

    2009-01-01

    The aim of this report was monitored the family house with radon concentration above radon limit for inhabited areas during one year. We were studied radon concentration changes in different rooms this house. Knowledge concerning of variations of radon activity concentration in family house were obtained. Daily variations show a maximum in the morning and a minimum in the afternoon. The seasonal variations show a minimum in spring months (March -April) and a maximum in early autumn (September). The radon concentration in the upstairs room was similar but ten-times lower than radon concentration in the downstairs room. In next period, the obtained results will be analysed in detail and different model describing the behaviour of radon in indoor air will be tested too. (authors)

  10. The Allergen Der p3 from House Dust Mite Stimulates Store-Operated Ca2+ Channels and Mast Cell Migration through PAR4 Receptors.

    Science.gov (United States)

    Lin, Yu-Ping; Nelson, Charmaine; Kramer, Holger; Parekh, Anant B

    2018-04-19

    The house dust mite is the principal source of perennial aeroallergens in man. How these allergens activate innate and adaptive immunity is unclear, and therefore, there are no therapies targeting mite allergens. Here, we show that house dust mite extract activates store-operated Ca 2+ channels, a common signaling module in numerous cell types in the lung. Activation of channel pore-forming Orai1 subunits by mite extract requires gating by STIM1 proteins. Although mite extract stimulates both protease-activated receptor type 2 (PAR2) and PAR4 receptors, Ca 2+ influx is more tightly coupled to the PAR4 pathway. We identify a major role for the serine protease allergen Der p3 in stimulating Orai1 channels and show that a therapy involving sub-maximal inhibition of both Der p3 and Orai1 channels suppresses mast cell activation to house dust mite. Our results reveal Der p3 as an important aeroallergen that activates Ca 2+ channels and suggest a therapeutic strategy for treating mite-induced asthma. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Maatregelen ter vermindering van fijnstofemissie uit pluimveehouderij: validatie van een luchtwassysteem met water als wasvloeistof bij twee pluimveebedrijven = Measures to reduce fine dust emissions from poultry housings: validation of a scrubber system with water as scrubbing solution at two poultry farms

    NARCIS (Netherlands)

    Melse, R.W.; Hol, J.M.G.; Dousma, F.; Nijeboer, G.M.; Huis in 'T Veld, J.W.H.

    2011-01-01

    In this study the removal efficiency for fine dust (PM10 and PM2.5) has been determined at two scrubbers located at two different poultry houses in addition, inlet and outlet concentrations were measured for ammonia, greenhouse gases and odour.

  12. Modeling of surface dust concentrations using neural networks and kriging

    Science.gov (United States)

    Buevich, Alexander G.; Medvedev, Alexander N.; Sergeev, Alexander P.; Tarasov, Dmitry A.; Shichkin, Andrey V.; Sergeeva, Marina V.; Atanasova, T. B.

    2016-12-01

    Creating models which are able to accurately predict the distribution of pollutants based on a limited set of input data is an important task in environmental studies. In the paper two neural approaches: (multilayer perceptron (MLP)) and generalized regression neural network (GRNN)), and two geostatistical approaches: (kriging and cokriging), are using for modeling and forecasting of dust concentrations in snow cover. The area of study is under the influence of dust emissions from a copper quarry and a several industrial companies. The comparison of two mentioned approaches is conducted. Three indices are used as the indicators of the models accuracy: the mean absolute error (MAE), root mean square error (RMSE) and relative root mean square error (RRMSE). Models based on artificial neural networks (ANN) have shown better accuracy. When considering all indices, the most precision model was the GRNN, which uses as input parameters for modeling the coordinates of sampling points and the distance to the probable emissions source. The results of work confirm that trained ANN may be more suitable tool for modeling of dust concentrations in snow cover.

  13. Evaluating Ice Nucleating Particle Concentrations From Prognostic Dust Minerals in an Earth System Model

    Science.gov (United States)

    Perlwitz, J. P.; Knopf, D. A.; Fridlind, A. M.; Miller, R. L.; Pérez García-Pando, C.; DeMott, P. J.

    2016-12-01

    The effect of aerosol particles on the radiative properties of clouds, the so-called, indirect effect of aerosols, is recognized as one of the largest sources of uncertainty in climate prediction. The distribution of water vapor, precipitation, and ice cloud formation are influenced by the atmospheric ice formation, thereby modulating cloud albedo and thus climate. It is well known that different particle types possess different ice formation propensities with mineral dust being a superior ice nucleating particle (INP) compared to soot particles. Furthermore, some dust mineral types are more proficient INP than others, depending on temperature and relative humidity.In recent work, we have presented an improved dust aerosol module in the NASA GISS Earth System ModelE2 with prognostic mineral composition of the dust aerosols. Thus, there are regional variations in dust composition. We evaluated the predicted mineral fractions of dust aerosols by comparing them to measurements from a compilation of about 60 published literature references. Additionally, the capability of the model to reproduce the elemental composition of the simulated dusthas been tested at Izana Observatory at Tenerife, Canary Islands, which is located off-shore of Africa and where frequent dust events are observed. We have been able to show that the new approach delivers a robust improvement of the predicted mineral fractions and elemental composition of dust.In the current study, we use three-dimensional dust mineral fields and thermodynamic conditions, which are simulated using GISS ModelE, to calculate offline the INP concentrations derived using different ice nucleation parameterizations that are currently discussed. We evaluate the calculated INP concentrations from the different parameterizations by comparing them to INP concentrations from field measurements.

  14. Decreased Mitochondrial DNA Content in Association with Exposure to Polycyclic Aromatic Hydrocarbons in House Dust during Wintertime: From a Population Enquiry to Cell Culture

    Science.gov (United States)

    Pieters, Nicky; Koppen, Gudrun; Smeets, Karen; Napierska, Dorota; Plusquin, Michelle; De Prins, Sofie; Van De Weghe, Hendrik; Nelen, Vera; Cox, Bianca; Cuypers, Ann; Hoet, Peter; Schoeters, Greet; Nawrot, Tim S.

    2013-01-01

    Polycyclic aromatic hydrocarbons (PAHs) are widespread environmental pollutants that are formed in combustion processes. At the cellular level, exposure to PAHs causes oxidative stress and/or some of it congeners bind to DNA, which may interact with mitochondrial function. However, the influence of these pollutants on mitochondrial DNA (mtDNA) content remains largely unknown. We determined whether indoor exposure to PAHs is associated with mitochondrial damage as represented by blood mtDNA content. Blood mtDNA content (ratio mitochondrial/nuclear DNA copy number) was determined by real-time qPCR in 46 persons, both in winter and summer. Indoor PAH exposure was estimated by measuring PAHs in sedimented house dust, including 6 volatile PAHs and 8 non-volatile PAHs. Biomarkers of oxidative stress at the level of DNA and lipid peroxidation were measured. In addition to the epidemiologic enquiry, we exposed human TK6 cells during 24 h at various concentrations (range: 0 to 500 µM) of benzo(a)pyrene and determined mtDNA content. Mean blood mtDNA content averaged (±SD) 0.95±0.185. The median PAH content amounted 554.1 ng/g dust (25th–75th percentile: 390.7–767.3) and 1385ng/g dust (25th–75th percentile: 1000–1980) in winter for volatile and non-volatile PAHs respectively. Independent for gender, age, BMI and the consumption of grilled meat or fish, blood mtDNA content decreased by 9.85% (95% CI: −15.16 to −4.2; p = 0.002) for each doubling of non-volatile PAH content in the house dust in winter. The corresponding estimate for volatile PAHs was −7.3% (95% CI: −13.71 to −0.42; p = 0.04). Measurements of oxidative stress were not correlated with PAH exposure. During summer months no association was found between mtDNA content and PAH concentration. The ability of benzo(a)pyrene (range 0 µM to 500 µM) to lower mtDNA content was confirmed in vitro in human TK6 cells. Based on these findings, mtDNA content can be a target of PAH toxicity in humans

  15. Decreased mitochondrial DNA content in association with exposure to polycyclic aromatic hydrocarbons in house dust during wintertime: from a population enquiry to cell culture.

    Directory of Open Access Journals (Sweden)

    Nicky Pieters

    Full Text Available Polycyclic aromatic hydrocarbons (PAHs are widespread environmental pollutants that are formed in combustion processes. At the cellular level, exposure to PAHs causes oxidative stress and/or some of it congeners bind to DNA, which may interact with mitochondrial function. However, the influence of these pollutants on mitochondrial DNA (mtDNA content remains largely unknown. We determined whether indoor exposure to PAHs is associated with mitochondrial damage as represented by blood mtDNA content. Blood mtDNA content (ratio mitochondrial/nuclear DNA copy number was determined by real-time qPCR in 46 persons, both in winter and summer. Indoor PAH exposure was estimated by measuring PAHs in sedimented house dust, including 6 volatile PAHs and 8 non-volatile PAHs. Biomarkers of oxidative stress at the level of DNA and lipid peroxidation were measured. In addition to the epidemiologic enquiry, we exposed human TK6 cells during 24 h at various concentrations (range: 0 to 500 µM of benzo(apyrene and determined mtDNA content. Mean blood mtDNA content averaged (± SD 0.95 ± 0.185. The median PAH content amounted 554.1 ng/g dust (25(th-75(th percentile: 390.7-767.3 and 1385 ng/g dust (25(th-75(th percentile: 1000-1980 in winter for volatile and non-volatile PAHs respectively. Independent for gender, age, BMI and the consumption of grilled meat or fish, blood mtDNA content decreased by 9.85% (95% CI: -15.16 to -4.2; p = 0.002 for each doubling of non-volatile PAH content in the house dust in winter. The corresponding estimate for volatile PAHs was -7.3% (95% CI: -13.71 to -0.42; p = 0.04. Measurements of oxidative stress were not correlated with PAH exposure. During summer months no association was found between mtDNA content and PAH concentration. The ability of benzo(apyrene (range 0 µM to 500 µM to lower mtDNA content was confirmed in vitro in human TK6 cells. Based on these findings, mtDNA content can be a target of PAH toxicity in humans.

  16. Dust and airborne exposure to allergens derived from cockroach (Blattella germanica) in low-cost public housing in Strasbourg (France).

    Science.gov (United States)

    de Blay, F; Sanchez, J; Hedelin, G; Perez-Infante, A; Vérot, A; Chapman, M; Pauli, G

    1997-01-01

    Although a strong association between allergy to cockroach (CR) and asthma has been observed in the United States and Asia, there are little data about the extent of exposure to CR allergen in Europe. To determine the levels of CR allergens in dust samples from apartments in Strasbourg and to determine the concentration and size of CR allergens in the air. Nine apartments in a public housing complex were chosen on the basis of visual evidence of CR infestation. Levels of CR allergens (Bla g 1 and Bla g 2) in kitchen and mattress dust samples were measured by immunoassay with the use of monoclonal antibodies. Air was sampled for 3 to 8 hours in the kitchen under undisturbed conditions, during artificial disturbance, and during normal domestic activity by using an impinger and a parallel glass fiber filter and at flow rates of 2 to 20 L/min. Airborne CR and mite allergens were measured concurrently in the bedroom of one apartment before, during, and after artificial disturbance. High levels of Bla g 1 and Bla g 2 were found in kitchen dust from the nine apartments (geometric means of 3919 U/gm [range 530 to 14306 U/gm] and 497 U/gm [range 73 to 1946 U/gm], respectively). Under undisturbed conditions, airborne CR allergens were not detectable in any of the apartments. During vigorous artificial disturbance, Bla g 1 and Bla g 2 were detectable in air samples from seven apartments (geometric means of 4.5 U/m3 [range 0.7 to 17.2 U/m3] and 1.0 U/m3 [range 0.4 to 3.4 U/m3], respectively). Both allergens were predominantly collected on the first stage of the impinger, and 76% to 80% of the airborne allergen was associated with particles greater than 10 microns in diameter. The levels were significantly higher than those collected on the second or third stages of the impinger (p low-cost public housing in Strasbourg can be as high as or higher than the levels measured in towns in the United States. CR allergens become airborne during disturbance and are primarily associated

  17. Mitigation of houses with extremely high indoor radon concentrations

    International Nuclear Information System (INIS)

    Jiranek, M.; Neznal, M.

    2006-01-01

    Full text of publication follows: The paper reports on the experience of the Czech Technical University in dealing with mitigation of houses in which unusually high indoor radon concentrations were found. The whole process of remediation is illustrated by example of an old single-family house that was built in the area formed by highly permeable soils with high radon content in the soil air. T he house has a small cellar located under 1/5 of the ground floor area. Two types of floors, i.e. timber floors and cracked concrete slabs were found in the house. As a result of extremely high radon concentration in the sub-floor region (up to 600 kBq/m 3 ) and leaky structures in contact with soil, radon concentrations around 100 kBq/m 3 in the cellar and up to 60 kBq/m 3 in the living rooms on the ground floor were measured prior to mitigation. Mitigation measures that were carried out in the house consist of reconstruction of timber floors and installation of active soil depressurization. Timber floors were replaced with concrete slab fitted with damp proof membrane, thermal insulation and floor covering. The soil depressurization system was made up of two sections. The first section is composed of the network of perforated pipes inserted in the drainage layer placed under the new floors and four perforated tubes drilled under the existing floors. The soil air from this section is extracted by means of a roof fan installed at the top of the vertical exhaust pipe running inside the living space and terminating above the roof. The second section was designed to withdraw by means of a small fan radon-laden air from the filling in the floor above the cellar and from perforated tubes drilled into the sub-floor region under the rooms adjacent to the cellar. It serves also for the active ventilation of the cellar. Pressure, temperature and radon concentration sensors were installed into the drainage layer during the reconstruction of floors to record variations in these

  18. Large-scale coherent structures of suspended dust concentration in the neutral atmospheric surface layer: A large-eddy simulation study

    Science.gov (United States)

    Zhang, Yangyue; Hu, Ruifeng; Zheng, Xiaojing

    2018-04-01

    Dust particles can remain suspended in the atmospheric boundary layer, motions of which are primarily determined by turbulent diffusion and gravitational settling. Little is known about the spatial organizations of suspended dust concentration and how turbulent coherent motions contribute to the vertical transport of dust particles. Numerous studies in recent years have revealed that large- and very-large-scale motions in the logarithmic region of laboratory-scale turbulent boundary layers also exist in the high Reynolds number atmospheric boundary layer, but their influence on dust transport is still unclear. In this study, numerical simulations of dust transport in a neutral atmospheric boundary layer based on an Eulerian modeling approach and large-eddy simulation technique are performed to investigate the coherent structures of dust concentration. The instantaneous fields confirm the existence of very long meandering streaks of dust concentration, with alternating high- and low-concentration regions. A strong negative correlation between the streamwise velocity and concentration and a mild positive correlation between the vertical velocity and concentration are observed. The spatial length scales and inclination angles of concentration structures are determined, compared with their flow counterparts. The conditionally averaged fields vividly depict that high- and low-concentration events are accompanied by a pair of counter-rotating quasi-streamwise vortices, with a downwash inside the low-concentration region and an upwash inside the high-concentration region. Through the quadrant analysis, it is indicated that the vertical dust transport is closely related to the large-scale roll modes, and ejections in high-concentration regions are the major mechanisms for the upward motions of dust particles.

  19. An analysis of the correlation between dust storms in Korea and 137Cs nuclide concentration

    International Nuclear Information System (INIS)

    Choi, Soo-won; Kim, Jeong-hun; Shin, Sang-hwa; Hwang, Joo-ho

    2008-01-01

    Dust storms occur in Korea during spring time when fine dust is blown in from the far western regions of western China and Mongolia. A fine powdery dust is blown up into the sky and enters the upper reaches of the atmosphere where it is carried easterly across China then slowly falls to the ground on the Korean peninsula and Japan. The dust originates mostly in the Gobi dessert of China, as well as the yellow earth regions in the middle and upper streams of the Yellow river in China. Previous studies on dust storms have been limited to following or estimating their courses, distribution and frequency, or distribution of the heavy metals they transmit. However, since radionuclides exist in the dust, they must also exist in the dust storms. In this study, we analyzed the correlation of :1 37 Cs nuclide concentration based on a count of annual dust storm occurrence in the city of Suwon, South Korea and assessed seasonal differences of 137 Cs nuclide concentration

  20. Nunavut housing ventilation research 2003-2005

    Energy Technology Data Exchange (ETDEWEB)

    Fugler, D.

    2005-11-15

    Inuit children in Alaska and Nunavut have high rates of severe lower respiratory tract infections, with hospitalization rates of 300 per year for each 1000 infants. The aim of this research report was to summarize the findings of a pilot project measuring the indoor air quality (IAQ) in 20 Cape Dorset houses as well as a study measuring the ventilation rates of 100 house from 4 communities in Nunavut. The 20 house pilot study included a respiratory questionnaire; a detailed home inspection and data collection; a blower door airtightness test; 7 day measurements of nitrogen dioxide (NO{sub 2}), nicotine, carbon dioxide (CO{sub 2}), relative humidity and temperature; a natural air change rate testing using Brookhaven tracer gas technology; and settled floor dust and bed dust collection followed by biological analysis. The 100 house study recorded 3 to 5 days of house temperatures, relative humidity and CO{sub 2}. The Brookhaven tracer gas technique was used to establish house air change rate. A questionnaire was used to assess ventilation devices. A medical questionnaire was administered and an evaluation of hospitalization data was carried out. Results indicated that a large number of Nunavut houses were not adequately ventilated. In the 20 house study, a third of the houses showed air change rates that would be considered low by any ventilation standards, and that were very low when considering the high occupancy of the houses. In the hundred house study, almost all houses indicated a mean CO{sub 2} level over 1000 ppm, and peaks exceeded 2000 ppm in approximately half the houses. The concentrations were far higher than those seen in southern Canadian homes. It was concluded that the development and promotion of energy-efficient ventilation devices could help to resolve ventilation deficiencies in Nunavut. 2 figs.

  1. [Research on dust mite allergen gathered from filters of air-conditioners].

    Science.gov (United States)

    Zhan, Xiao-dong; Wu, Hua; Hu, Hui-min; Li, Chao-pin

    2015-12-01

    To discuss the relation between the dust mite allergen (Der) in air-conditioner filters and the asthma attack. The dust samples were collected from the filters of air-conditioners in dining rooms, shopping malls, hotels and households, respectively. The concentrations of Der f 1 and Der p1 were detected by ELISA, and the dust mite immune activities were determined by dot-ELISA. The concentrations of Der f 1 in the dining rooms, shopping malls, hotels and households were 1.52, 1.24, 1.31 µg/g and 1.46 µg/g respectively, and the concentrations of Der p 1 were 1.23, 1.12, 1.16 µg/ g and 1.18 µg, respectively. One hour after the running of air-conditioners, the concentrations of Der f 1 and Der p 1 in the air were higher than those before the running of air-conditioners, and the differences were significant (P air-conditioners in domestic houses in Wuhu City, and the allergens can induce asthma.

  2. Human health effects of dust exposure in anmial confinement buildings

    NARCIS (Netherlands)

    Iversen, M.; Kirychuk, S.; Drost, H.; Jacobson, L.

    2001-01-01

    Work in swine and poultry units is associated with exposure to significant levels of organic dust and endotoxins with the highest concentrations found in poultry houses, whereas values found in dairy and in cattle farming are much lower. Corresponding to this is an excess of work-related respiratory

  3. House Dust Mite Prevalence in the House of Patients with Atopic Dermatitis in Mashhad, Iran

    Directory of Open Access Journals (Sweden)

    Toktam Ziyaei

    2017-06-01

    Full Text Available Background: Being exposed to house dust mites intensifies atopic dermatitis. This study has investigated the con­tamination rate with Dermatophagoides mites in patient's residential home with atopic dermatitis.Methods: In this cross-sectional study, 40 patients took part with atopic dermatitis (positive or negative for mites by prick Dermal Test. Samples were collected from 3 locations (living room, bedroom and bed by vacuum cleaner. Dust samples (transferred to freezer -20 ˚C were examined by direct method and flotation. The data were analyzed using statistical SPSS vr.20 software.Results: Twenty patients of positive prick test included 8 (40% male and 12 (60% female. The results of direct observation of mites: 7 cases (35% in bedding sheets, 6 cases (30% bedrooms' carpet, 3 cases (15% living room's carpet. Twenty patients of negative prick test included 8 (40% male and 12 (60% female. Only mites were found (5% in living room's carpets of negative prick test patients. Dermatophagoides pteronyssinus was more frequent than Dermatophagoides farinae. (98% vs 83%.Conclusion: Fifty-five percent of residential homes of prick test positive patients and only 5% of residential homes of prick test negative patients were positive for mite. Sunshine provided home had fewer mites than home where sunshine is not provided. Prick test positive patients used handmade carpets more than machine made ones. In posi­tive prick test patients, mites were found in bed sheet and bedroom’s carpet more than negative prick test patient's sheets and carpets.

  4. The effect of mineral dust transport on PM10 concentrations and physical properties in Istanbul during 2007-2014

    Science.gov (United States)

    Flores, Rosa M.; Kaya, Nefel; Eşer, Övgü; Saltan, Şehnaz

    2017-11-01

    Mineral dust is the most significant source of natural particulate matter. In urban regions, where > 50% of the world population is currently living, local emissions of particulate matter are further aggravated by mineral dust loadings from deserts. The megacity of Istanbul is located in an area sensitive to local pollution due to transportation (i.e., private cars, public transportation, aircrafts, ships, heavy diesel trucks, etc.), industrial emissions, residential heating, and long-range transport from Europe, Asia, and deserts. In this work, the effect of desert dust transport on PM10 concentrations and physical properties was investigated for the period of 2007-2014 in the touristic area of Aksaray, Istanbul. The Dust Regional Atmospheric Model (DREAM8b) was used to predict dust loading in Istanbul during dust transport events. Variations on surface PM10 concentrations were investigated according to seasons and during dust transport events. Cluster analysis of air mass backward trajectories was useful to understand frequency analysis and air mass trajectory dependence of PM10 concentrations on dust loadings. The effect of desert dust transport on aerosol optical depths was also investigated. It was observed that PM10 concentrations exceeded the air quality standard of 50 μg m- 3 50% of the time during the study period. The largest number of exceedances in air quality standard occurred during the spring and winter seasons. Approximately 40-60% of the dust loading occurs during the spring. Desert dust and non-desert dust sources contribute to 22-72% and 48-81% of the ground-level PM10 concentrations in Aksaray, Istanbul during the study period. Averaged AOD observed during dust transport events in spring and summer ranged 0.35-0.55. Cluster analysis resolved over 82% the variability of individual air mass backward trajectories into 5 clusters. Overall, air masses arriving to Istanbul at 500 m are equally distributed into northern (52%) and southern (48

  5. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  6. PARTICULATE MATTER CONCENTRATION AND EMISSION FACTOR IN THREE DIFFERENT LAYING HEN HOUSING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Annamaria Costa

    2009-09-01

    Full Text Available The aim of this study was to evaluate PM10 concentration in three different laying hens houses (traditional battery cages with aerated open manure storage, aviary system and vertical tiered cages with manure belts with forced air drying and to evaluate particulate matter emission into atmosphere during one year of observation. Internal and external temperature and relative humidity, ventilation rate, PM10 concentration have been continuously monitored in order to evaluate particulate matter concentration changes during the day and the season and to define PM10 emission factors. PM10 concentration was corrected by gravimetric technique to lower measurements error. In the aviary system house, TSP and fine particulate matter (particles smaller than 2.5 micron concentration was measured. Average yearly PM10 concentration was remarkably higher in the aviary system house with 0.215 mg m-3 vs 108 mg m-3 for the ventilated belt house and vs 0.094 mg m-3 for the traditional battery cages house. In the Aviary system housing, TSP concentration was 0.444 mg m-3 and PM2.5 was 0.032 mg m-3, highlighting the existence of a severe working environment for men and animals. Recorded values for PM10 emission were 0.433 mg h-1 hen-1 for battery cages housing type, 0.081 mg h-1 hen-1 for ventilated belt cages house, values lower than those available in literature, while the aviary system housing type showed the highest PM10 emission (1.230 mg h-1 hen-1 with appreciable peaks during the morning, together with the increased animal activity and daily farmer operations, as feed administration, cleaning and droppings removal.

  7. Impact of dust filter installation in ironworks and construction on brownfield area on the toxic metal concentration in street and house dust (Celje, Slovenia).

    Science.gov (United States)

    Zibret, Gorazd

    2012-05-01

    This article presents the impact of the ecological investment in ironworks (dust filter installation) and construction works at a highly contaminated brownfield site on the chemical composition of household dust (HD) and street sediment (SS) in Celje, Slovenia. The evaluation is based on two sampling campaigns: the first was undertaken 1 month before the ecological investment became operational and the second 3 years later. The results show that dust filter installations reduced the content of Co, Cr, Fe, Mn, Mo, W and Zn on average by 58% in HD and by 51% in SS. No reduction was observed at sampling points in the upwind direction from the ironworks. By contrast, the impact of the construction works on the highly contaminated brownfield site was detected by a significant increase (on average by 37%) of elements connected to the brownfield contamination in SS. Such increase was not detected in HD.

  8. Housing and population sprawl near tailings storage facilities in the Witwatersrand: 1952 to current

    Directory of Open Access Journals (Sweden)

    Melanie A. Kneen

    2015-11-01

    Full Text Available Mining, tailings storage facilities (TSFs, dust pollution and growth in residential housing development are synonymous with the Witwatersrand, South Africa. Encroachment of housing onto land close to TSFs, i.e. areas rendered marginal because of the dust hazard and risk of structural failure, has continued unabated for decades, intensifying human exposure to windblown mineral dust. Recent research indicates that the finer milling used for modern gold extraction results in aeolian dust emanating from the TSFs which contributes to a higher proportion of inhalable particles in the source material. Air quality dispersion modelling, validated by ambient aerosol monitoring campaigns, indicates that episodic dust events generate particulate matter (PM10 and, specifically, quartz dust concentrations that are unhealthy at distances of up to 2 km downwind from TSFs. This contribution documented residential development from 1952 to 2011 (using historical aerial photographs, census data from 2001 and 2011 and ancillary information to determine the population exposed to dust emanations from the TSFs. Using the images, land use was classified into residential areas, TSF footprints and open areas, onto which a series of 500 m buffer zone contours were superimposed. The resulting statistics were used to assess the populations exposed to dust hazard within the defined buffer zones. Overall, housing development has experienced a growth of approximately 700% since 1952 at a rate of 14% per year. Analysis of recent monitoring campaign data has confirmed multiple occurrences of quartzrich inhalable dust in residential settings at levels that exceed occupational health standards, extrapolated to values for population exposure.

  9. A study on the optimal design of a cyclone system for vacuum cleaner with the consideration of house dust

    International Nuclear Information System (INIS)

    Ha, Gun Ho; Kim, Eung Dal; Kim, Young Soo; Lee, Jae Keun; Ahn, Young Chull; Kim, Dong Gyu

    2011-01-01

    Cyclone, a type of particle collector widely used in the field of ambient sampling and industrial particulate control, is the principal type of gas-solids separator that use a centrifugal force. The goal of this study is to transform conventional cyclone into a new type of cyclone that can be used for the household vacuum cleaners. To meet the goal, first, the analysis about local environment and dust is carried out. Second, it must have enough high-efficiency not to reduce suction power due to clogging of exhaust filter unit. Two single cyclones with central-hopper-dust-outlet and side-wall-dust-outlet and a twin cyclone are designed and fabricated to evaluate, and compare, their dust collection efficiencies and pressure drops. The measurements of separation efficiency for dust by using DMT test dust type 08 are carried out. House dust experiment is additionally performed to check the local matters applicability such as tissue papers, fur and hairs. The collection efficiency of the twin cyclone is found to be 3-6% greater than those of two single cyclones with the same body diameter, inlet and inner cylinder diameter. Twin cyclone with a large body diameter, a small inner cylinder diameter, a short inner cylinder, a narrow inlet has high separation efficiency. This result indicates the possibility of achieving higher collection efficiencies with a twin cyclone

  10. Air pollution assessment based on elemental concentration of leaves tissue and foliage dust along an urbanization gradient in Vienna

    International Nuclear Information System (INIS)

    Simon, Edina; Braun, Mihaly; Vidic, Andreas; Bogyo, David; Fabian, Istvan; Tothmeresz, Bela

    2011-01-01

    Foliage dust contains heavy metal that may have harmful effects on human health. The elemental contents of tree leaves and foliage dust are especially useful to assess air environmental pollution. We studied the elemental concentrations in foliage dust and leaves of Acer pseudoplatanus along an urbanization gradient in Vienna, Austria. Samples were collected from urban, suburban and rural areas. We analysed 19 elements in both kind of samples: aluminium, barium, calcium, copper, iron, potassium, magnesium, sodium, phosphor, sulphur, strontium and zinc. We found that the elemental concentrations of foliage dust were significantly higher in the urban area than in the rural area for aluminium, barium, iron, lead, phosphor and selenium. Elemental concentrations of leaves were significantly higher in urban than in rural area for manganese and strontium. Urbanization changed significantly the elemental concentrations of foliage dust and leaves and the applied method can be useful for monitoring the environmental load. - Highlights: → We studied the elements in dust and leaves along an urbanization gradient, Austria. → We analysed 19 elements: Al, Ba, Ca, Cd, Cu, Fe, K, Mg, Na, P, Pb, S, Sr and Zn. → Elemental concentrations were higher in urban area than in the rural area. → Studied areas were separated by CDA based on the elemental concentrations. → Dust and leaves can be useful for monitoring the environmental load. - Studying the elements (Al, Ba, Ca, Cu, Fe, K, Mg, Na, P, S, Sr, Zn) in dust and leaves along an urbanization gradient in Wien, Austria we found that the elemental concentrations of foliage dust were significantly higher in the urban area than in the rural area for Al, Ba, Fe, Pb, P and Se, and concentrations of leaves were significantly higher in urban than in rural area for Mn and Sr.

  11. Air pollution assessment based on elemental concentration of leaves tissue and foliage dust along an urbanization gradient in Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Edina, E-mail: edina.simon@gmail.com [Department of Ecology, University of Debrecen, H-4010 Debrecen, P.O. Box 71 (Hungary); Braun, Mihaly [Department of Inorganic and Analytical Chemistry, University of Debrecen, H-4010 Debrecen, P.O. Box 21 (Hungary); Vidic, Andreas [Department fuer Naturschutzbiologie, Vegetations- und Landschaftsoekologie, Universitat Wien, Althanstrasse 14, 1090 Wien (Austria); Bogyo, David [Department of Ecology, University of Debrecen, H-4010 Debrecen, P.O. Box 71 (Hungary); Fabian, Istvan [Department of Inorganic and Analytical Chemistry, University of Debrecen, H-4010 Debrecen, P.O. Box 21 (Hungary); Tothmeresz, Bela [Department of Ecology, University of Debrecen, H-4010 Debrecen, P.O. Box 71 (Hungary)

    2011-05-15

    Foliage dust contains heavy metal that may have harmful effects on human health. The elemental contents of tree leaves and foliage dust are especially useful to assess air environmental pollution. We studied the elemental concentrations in foliage dust and leaves of Acer pseudoplatanus along an urbanization gradient in Vienna, Austria. Samples were collected from urban, suburban and rural areas. We analysed 19 elements in both kind of samples: aluminium, barium, calcium, copper, iron, potassium, magnesium, sodium, phosphor, sulphur, strontium and zinc. We found that the elemental concentrations of foliage dust were significantly higher in the urban area than in the rural area for aluminium, barium, iron, lead, phosphor and selenium. Elemental concentrations of leaves were significantly higher in urban than in rural area for manganese and strontium. Urbanization changed significantly the elemental concentrations of foliage dust and leaves and the applied method can be useful for monitoring the environmental load. - Highlights: > We studied the elements in dust and leaves along an urbanization gradient, Austria. > We analysed 19 elements: Al, Ba, Ca, Cd, Cu, Fe, K, Mg, Na, P, Pb, S, Sr and Zn. > Elemental concentrations were higher in urban area than in the rural area. > Studied areas were separated by CDA based on the elemental concentrations. > Dust and leaves can be useful for monitoring the environmental load. - Studying the elements (Al, Ba, Ca, Cu, Fe, K, Mg, Na, P, S, Sr, Zn) in dust and leaves along an urbanization gradient in Wien, Austria we found that the elemental concentrations of foliage dust were significantly higher in the urban area than in the rural area for Al, Ba, Fe, Pb, P and Se, and concentrations of leaves were significantly higher in urban than in rural area for Mn and Sr.

  12. Using paired soil and house dust samples in an in vitro assay to assess the post ingestion bioaccessibility of sorbed fipronil

    Science.gov (United States)

    For children, ingestion of soils and house dusts can be an important exposure pathway for regulated organic compounds. Following ingestion, the extent to which compounds desorb and become bioaccessible is a critical determinant of systemic adsorption.We characterized the physicoc...

  13. Radon concentrations in houses around the Plomin coal-fired power plant

    International Nuclear Information System (INIS)

    Lokobauer, N.; Franic, Z.; Sencar, J.; Bauman, A.; Sokolovic, E.

    1997-01-01

    Investigation of radon activity concentration in houses around the Plomin coal-fired power plant (Istrian Peninsula) started in the winter of 1990 upon the assumption that certain old houses in this region were built using mortar and plaster prepared from slag and ash. This paper presents the results of a preliminary investigation carried out in the winter of 1990 and spring of 1991, when the difference between radon levels in old and newly built houses was first noted, and the subsequent data obtained by radon measurements in 40 selected houses in the period from 1992 to 1994. The average annual radon activity concentrations in the old houses ranged from 55 Bqm -3 to 426 Bqm -3 (mean value 146 ± 91 Bqm -3 ) and in more recently built houses from 16 Bqm -3 to 67 Bqm -3 (mean value 36 ± 13 Bqm -3 ). The average annual effective doses from inhalation of radon progeny for the inhabitants living in the old and newly built houses were estimated to be 2.7 mSv and 0.7 mSv, respectively. (Author)

  14. Ambiência aérea em alojamento de frangos de corte: poeira e gases Aerial environment in broiler housing: dust and gases

    Directory of Open Access Journals (Sweden)

    Irenilza de A. Nääs

    2007-08-01

    Full Text Available A qualidade do ar em ambientes de produção animal vem sendo referenciada como ponto de interesse em estudos de sistema de controle ambiental, focando tanto a saúde dos animais que vivem em total confinamento, quanto a dos trabalhadores. O objetivo do trabalho foi determinar a variação da qualidade da ambiência aérea em dois tipos de galpões criatórios de frangos de corte: convencional (Gc e tipo túnel (Gt. Os valores de poeira total, em ambos os galpões, ofereceram condições adequadas às aves; entretanto, as concentrações de poeira respirável no ar estiveram acima do limite recomendado para humanos. A concentração de monóxido de carbono, na fase de aquecimento, esteve acima dos 10 ppm máximos recomendados, no período avaliado, sendo superior na época de frio no galpão Gt (30 ppm, comparada ao galpão Gc (18 ppm. Os picos de concentração de amônia no ar estiveram acima dos 20 ppm máximos recomendados às aves a partir do 20º dia de produção, em ambos os galpões, e na média diária, por período superior no galpão Gt (4h30, quando comparado ao Gc (2h45. Foram encontrados apenas traços de óxido nítrico e metano, enquanto a concentração de gás carbônico, avaliada em condições diurnas, atendeu aos limites máximos permitidos, tanto para aves quanto para o trabalhador.Air quality in animal production environment has been refereed as an interesting point for studies in environmental control systems with the focus both to the animal health which live in total confinement, as to the workers. The objective of this research was to determine the variation on the aerial environmental quality in two types of broiler housing: conventional (Gc and tunnel type (Gt. The total dust values in both houses offered adequate rearing conditions to the birds; however, regarding the inhale dust in the air was above the limits recommended for humans. Carbon monoxide concentration in the heating phase during the evaluated period

  15. Radon concentration in a house of Calvados

    International Nuclear Information System (INIS)

    Leleyter, L.; Riffault, B.; Mazenc, B.

    2010-01-01

    Recent studies indicate a link between the risk of lung cancer and residential radon exposure. However, in France, awareness of this problem was made relatively late. Accordingly this study examines the radon concentration in a private home in Calvados (Normandy region). Findings show that the presence of a fireplace in a house can accelerate radon convective transfer, and that simple adjustments to interior and exterior accommodation can significantly reduce radon concentrations in the home. (authors)

  16. Quantitative detection of mass concentration of sand-dust storms via wind-profiling radar and analysis of Z- M relationship

    Science.gov (United States)

    Wang, Minzhong; Ming, Hu; Ruan, Zheng; Gao, Lianhui; Yang, Di

    2018-02-01

    With the aim to achieve quantitative monitoring of sand-dust storms in real time, wind-profiling radar is applied to monitor and study the process of four sand-dust storms in the Tazhong area of the Taklimakan Desert. Through evaluation and analysis of the spatial-temporal distribution of reflectivity factor, it is found that reflectivity factor ranges from 2 to 18 dBz under sand-dust storm weather. Using echo power spectrum of radar vertical beams, sand-dust particle spectrum and sand-dust mass concentration at the altitude of 600 ˜ 1500 m are retrieved. This study shows that sand-dust mass concentration reaches 700 μg/m3 under blowing sand weather, 2000 μg/m3 under sand-dust storm weather, and 400 μg/m3 under floating dust weather. The following equations are established to represent the relationship between the reflectivity factor and sand-dust mass concentration: Z = 20713.5 M 0.995 under floating dust weather, Z = 22988.3 M 1.006 under blowing sand weather, and Z = 24584.2 M 1.013 under sand-dust storm weather. The retrieval results from this paper are almost consistent with previous monitoring results achieved by former researchers; thus, it is implied that wind-profiling radar can be used as a new reference device to quantitatively monitor sand-dust storms.

  17. Fungi of the house dust in Riyadh, Saudi Arabia.

    Science.gov (United States)

    Saad, R R; el-Gindy, A A

    1990-01-01

    30 species belonging to 18 genera were isolated from floor dust of 30 homes in Riyadh. Out of them 16 species and 10 genera were isolated from dust of air conditioners of the same homes. The most common genera in floor dust were Aspergillus, Penicillium and Cladosporium. Aspergillus repens, A. amstelodami, A. versicolor, A. fumigatus, Penicillium purpurogenum, P. crustosum, Cladosporium cladosporoides and C. herbarum were frequently isolated. The most abundant genera in air conditioner dust were Aspergillus and Penicillium. Aspergillus fumigatus, A. ochraceus, A. terreus, Penicillium oxalicium and P. crustosum were most frequent species.

  18. Surface dust wipes are the best predictors of blood leads in young children with elevated blood lead levels

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Macquarie University, North Ryde NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113 (Australia); Anderson, Phil [Information and Statistics Group, Australian Institute of Health and Welfare, Canberra ACT 2601 (Australia); Faculty of Health, University of Canberra, Canberra ACT 2601 (Australia); Taylor, Alan [Department of Psychology, Macquarie University, Sydney NSW 2109 (Australia)

    2013-10-15

    Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floor wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10

  19. Concentrations of polychlorinated biphenyls in soil and indoor dust associated with electricity generation facilities in Lagos, Nigeria.

    Science.gov (United States)

    Folarin, Bilikis Temitope; Abdallah, Mohamed Abou-Elwafa; Oluseyi, Temilola; Olayinka, Kehinde; Harrad, Stuart

    2018-09-01

    Concentrations of 7 indicator polychlorinated biphenyls (PCBs) were measured in dust and soil samples from 12 power stations collected over the two major seasons of the Nigerian climate. Median ƩPCB 7 concentrations in soil ranged from 2 ng/g for power station A to 220 ng/g for power station I; while those in dust ranged from 21 ng/g for power station L to 2200 ng/g for power station I. For individual congeners, median PCB concentrations ranged from 3.8 ng/g for PCB 101 to 52 ng/g for PCB 180 in dust, and  transmission > distribution). Congener patterns in dust and soil samples were compared using principal component analysis (PCA) with those in transformer oil samples from 3 of the power stations studied and with common PCB mixtures (Aroclors). This revealed congener patterns in soil were more closely related to that in the transformer oil than dust. Congener patterns in most samples were similar to Aroclor 1260. Concentrations of PCBs in soil samples close to the transformers significantly exceeded those in soil sampled further away. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Windows pollution problems of the dust concentration measurement based on scattering method

    International Nuclear Information System (INIS)

    Zhao Yanjun; Zhang Yongtao; Shi Xinyue; Xu Chuanlong; Wang Shimin

    2009-01-01

    The windows are separated the measurement system from the dust space in the light Scattering dust concentration measurement system. The windows are polluted unavoidably by the dust and the measurement error is produced. Based on the Mie Scattering theory, the measurement error is researched in this paper. The numerical simulation results show that the measurement error is related to the particles diameter distribution and the refractive index, but is independent of the particles average diameter. A novel photoelectricity sensor is developed in this paper in order to solve the measurement error by the windows pollution. The calculated method is brought out which can amend the measurement errors by the windows pollution and improve the measurement accuracy.

  1. The effect of encasings on quality of life in adult house dust mite allergic patients with rhinitis, asthma and/or atopic dermatitis

    NARCIS (Netherlands)

    Terreehorst, I.; Duivenvoorden, H. J.; Tempels-Pavlica, Z.; Oosting, A. J.; de Monchy, J. G. R.; Bruijnzeel-Koomen, C. A. F. M.; van Wijk, R. Gerth

    2005-01-01

    BACKGROUND: Environmental control has been put forward as an integral part of the management of house dust mite (HDM) allergy in sensitized patients. To validate this statement allergic disorders involved in HDM allergy--allergic asthma, rhinitis and atopic eczema/dermatitis syndrome (AEDS)--should

  2. The effect of encasings on quality of life in adult house dust mite allergic patients with rhinitis, asthma and/or atopic dermatitis

    NARCIS (Netherlands)

    Terreehorst, [No Value; Duivenvoorden, HJ; Tempels-Pavlica, Z; Oosting, AJ; de Monchy, JGR; Bruijnzeel-Koomen, CAFM; van Wijk, R.

    Background: Environmental control has been put forward as an integral part of the management of house dust mite (HDM) allergy in sensitized patients. To validate this statement allergic disorders involved in HDM allergy - allergic asthma, rhinitis and atopic eczema/dermatitis syndrome (AEDS) -

  3. Bacterial and fungal components in house dust of farm children, Rudolf Steiner school children and reference children--the PARSIFAL Study.

    Science.gov (United States)

    Schram, D; Doekes, G; Boeve, M; Douwes, J; Riedler, J; Ublagger, E; von Mutius, E; Budde, J; Pershagen, G; Nyberg, F; Alm, J; Braun-Fahrländer, C; Waser, M; Brunekreef, B

    2005-05-01

    Growing up on a farm and an anthroposophic lifestyle are associated with a lower prevalence of allergic diseases in childhood. It has been suggested that the enhanced exposure to endotoxin is an important protective factor of farm environments. Little is known about exposure to other microbial components on farms and exposure in anthroposophic families. To assess the levels and determinants of bacterial endotoxin, mould beta(1,3)-glucans and fungal extracellular polysaccharides (EPS) in house dust of farm children, Steiner school children and reference children. Mattress and living room dust was collected in the homes of 229 farm children, 122 Steiner children and 60 and 67 of their respective reference children in five European countries. Stable dust was collected as well. All samples were analysed in one central laboratory. Determinants were assessed by questionnaire. Levels of endotoxin, EPS and glucans per gram of house dust in farm homes were 1.2- to 3.2-fold higher than levels in reference homes. For Steiner children, 1.1- to 1.6-fold higher levels were observed compared with their reference children. These differences were consistently found across countries, although mean levels varied considerably. Differences between groups and between countries were also significant after adjustment for home and family characteristics. Farm children are not only consistently exposed to higher levels of endotoxin, but also to higher levels of mould components. Steiner school children may also be exposed to higher levels of microbial agents, but differences with reference children are much less pronounced than for farm children. Further analyses are, however, required to assess the association between exposure to these various microbial agents and allergic and airway diseases in the PARSIFAL population.

  4. Air pollution assessment based on elemental concentration of leaves tissue and foliage dust along an urbanization gradient in Vienna.

    Science.gov (United States)

    Simon, Edina; Braun, Mihály; Vidic, Andreas; Bogyó, Dávid; Fábián, István; Tóthmérész, Béla

    2011-05-01

    Foliage dust contains heavy metal that may have harmful effects on human health. The elemental contents of tree leaves and foliage dust are especially useful to assess air environmental pollution. We studied the elemental concentrations in foliage dust and leaves of Acer pseudoplatanus along an urbanization gradient in Vienna, Austria. Samples were collected from urban, suburban and rural areas. We analysed 19 elements in both kind of samples: aluminium, barium, calcium, copper, iron, potassium, magnesium, sodium, phosphor, sulphur, strontium and zinc. We found that the elemental concentrations of foliage dust were significantly higher in the urban area than in the rural area for aluminium, barium, iron, lead, phosphor and selenium. Elemental concentrations of leaves were significantly higher in urban than in rural area for manganese and strontium. Urbanization changed significantly the elemental concentrations of foliage dust and leaves and the applied method can be useful for monitoring the environmental load. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. House dust bioactivities predict skin prick test reactivity for children with high risk of allergy.

    Science.gov (United States)

    Kim, Haejin; Tse, Kevin; Levin, Linda; Bernstein, David; Reponen, Tiina; LeMasters, Grace; Lummus, Zana; Horner, Anthony A

    2012-06-01

    Although evidence suggests that ambient exposures to endotoxin and other immunostimulants during early life influence allergic risk, efforts to understand this host-environment relationship have been hampered by a paucity of relevant assays. These investigations determined whether parameters of house dust extract (HDE) bioactivity were predictive of allergen skin prick test (SPT) reactivity for infants at high risk of allergy participating in the Cincinnati Childhood Allergy and Air Pollution Study (CCAAPS). We conducted a nested case-control study, selecting 99 CCAAPS children who had positive SPT results to at least 1 aeroallergen at age 3 years and 101 subjects with negative SPT results. HDEs were prepared from dust samples collected from the subjects' homes at age 1 year. Murine splenocytes and bone marrow-derived dendritic cells were incubated with HDEs, and supernatant cytokine concentrations were determined by means of ELISA. Alternatively, bone marrow-derived dendritic cells were preincubated with HDEs, and then LPS-induced IL-6 responses were assessed. HDE endotoxin levels were determined by using the limulus amebocyte lysate assay. HDEs derived from the homes of children with positive (cases) and negative (control subjects) SPT results had similar bioactivities. However, when cases were considered in isolation, HDEs with higher levels of bioactivity were significantly associated with children who had lower numbers of positive SPT results. Analogous statistical analyses did not identify any association between HDE endotoxin levels and the aeroallergen sensitization profiles of children included in this study. HDE immunostimulatory activities predicted the aeroallergen sensitization status of CCAAPS subjects better than HDE endotoxin levels. These results provide the first published evidence that HDE bioassays have clinical relevance in predicting atopic risk. Copyright © 2012 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All

  6. Evaluation of errors and limits of the 63-μm house-dust-fraction method, a surrogate to predict hidden moisture damage

    Directory of Open Access Journals (Sweden)

    Assadian Ojan

    2009-10-01

    Full Text Available Abstract Background The aim of this study is to analyze possible random and systematic measurement errors and to detect methodological limits of the previously established method. Findings To examine the distribution of random errors (repeatability standard deviation of the detection procedure, collective samples were taken from two uncontaminated rooms using a sampling vacuum cleaner, and 10 sub-samples each were examined with 3 parallel cultivation plates (DG18. In this two collective samples of new dust, the total counts of Aspergillus spp. varied moderately by 25 and 29% (both 9 cfu per plate. At an average of 28 cfu/plate, the total number varied only by 13%. For the evaluation of the influence of old dust, old and fresh dust samples were examined. In both cases with old dust, the old dust influenced the results indicating false positive results, where hidden moist was indicated but was not present. To quantify the influence of sand and sieving, 13 sites were sampled in parallel using the 63-μm- and total dust collection approaches. Sieving to 63-μm resulted in a more then 10-fold enrichment, due to the different quantity of inert sand in each total dust sample. Conclusion The major errors during the quantitative evaluation from house dust samples for mould fungi as reference values for assessment resulted from missing filtration, contamination with old dust and the massive influence of soil. If the assessment is guided by indicator genera, the percentage standard deviation lies in a moderate range.

  7. Heavy Metal Concentrations in Ceiling Fan Dusts Sampled at Schools Around Serdang Area, Selangor

    International Nuclear Information System (INIS)

    Yap, C.K.; Krishnan, T.; Chew, W.

    2011-01-01

    In this study, ceiling fan dust samples were collected from three schools in the district of Serdang Selangor, Malaysia. The sampled dust were analysed for the concentrations of Cd, Cu, Fe, Ni, Pb and Zn. The heavy metal ranges found in all the schools were 2.96-7.74 μg/ g dry weight for Cd, 75-442 μg/ g dry weight for Cu, 3445-3852 μg/ g dry weight for Fe, 24-66 μg/ g dry weight for Ni, 140-734 μg/ g dry weight for Pb and 439-880 μg/ g dry weight for Zn. SMK Seri Serdang School was found to have elevated concentrations of Cd, Cu, Ni, Pb, and Zn which indicated the anthropogenic sources of the study sites. In comparison to other reported studies in the literature, the maximum levels of Cd, Cu, Ni, and Pb were comparable or higher to those cities reported. Therefore, more monitoring studies should be conducted in future since dusts could be related to human health hazards and the dusts can be used as a potential monitoring tool for heavy metal pollution in the atmosphere. (author)

  8. Sources of radioactive contamination inside houses

    International Nuclear Information System (INIS)

    Sajet, A.S.

    2010-01-01

    People may be exposed at home to multiple sources of nuclear radiation such as gamma, beta and alpha rays emitters. House atmosphere is polluted with nuclear radiation from water pollutants and rocks used in the construction. Radon is the only radioactive non-metallic element. Environmental organizations estimated that all houses contain varying concentrations of radon gas, and the residents are exposed to levels of radon over the years. The source of radon in houses is uranium, which may be found in rocks of the house, soil of the garden, water of the deep artesian wells and building materials, especially granite rocks. Breathing air that contains high levels of radon causes lung cancer. Radon is the second cause of lung disease after smoking. There are many means to reduce house pollution including: utilisation of air filters to remove contaminated dust particles, keep residential areas away from the establishments that use nuclear technology or embedded by nuclear waste, avoid using materials made from asbestos in construction works and proper use and disposal of chemicals and medicines containing radioactive isotopes. (author)

  9. Dust radiative forcing in snow of the Upper Colorado River Basin: 1. A 6 year record of energy balance, radiation, and dust concentrations

    Science.gov (United States)

    Painter, Thomas H.; Skiles, S. Mckenzie; Deems, Jeffrey S.; Bryant, Ann C.; Landry, Christopher C.

    2012-07-01

    Dust in snow accelerates snowmelt through its direct reduction of snow albedo and its further indirect reduction of albedo by accelerating the growth of snow grains. Since the westward expansion of the United States that began in the mid-19th century, the mountain snow cover of the Colorado River Basin has been subject to five-fold greater dust loading, largely from the Colorado Plateau and Great Basin. Radiative forcing of snowmelt by dust is not captured by conventional micrometeorological measurements, and must be monitored by a more comprehensive suite of radiation instruments. Here we present a 6 year record of energy balance and detailed radiation measurements in the Senator Beck Basin Study Area, San Juan Mountains, Colorado, USA. Data include broadband irradiance, filtered irradiance, broadband reflected flux, filtered reflected flux, broadband and visible albedo, longwave irradiance, wind speed, relative humidity, and air temperatures. The gradient of the snow surface is monitored weekly and used to correct albedo measurements for geometric effects. The snow is sampled weekly for dust concentrations in plots immediately adjacent to each tower over the melt season. Broadband albedo in the last weeks of snow cover ranged from 0.33 to 0.55 across the 6 years and two sites. Total end of year dust concentration in the top 3 cm of the snow column ranged from 0.23 mg g-1 to 4.16 mg g-1. These measurements enable monitoring and modeling of dust and climate-driven snowmelt forcings in the Upper Colorado River Basin.

  10. Variability in the correlation between Asian dust storms and chlorophyll a concentration from the North to Equatorial Pacific.

    Directory of Open Access Journals (Sweden)

    Sai-Chun Tan

    Full Text Available A long-term record of Asian dust storms showed seven high-occurrence-frequency centers in China. The intrusion of Asian dust into the downwind seas, including the China seas, the Sea of Japan, the subarctic North Pacific, the North Pacific subtropical gyre, and the western and eastern Equatorial Pacific, has been shown to add nutrients to ocean ecosystems and enhance their biological activities. To explore the relationship between the transported dust from various sources to the six seas and oceanic biological activities with different nutrient conditions, the correlation between monthly chlorophyll a concentration in each sea and monthly dust storm occurrence frequencies reaching the sea during 1997-2007 was examined in this study. No correlations were observed between dust and chlorophyll a concentration in the 50 m China seas and the North Pacific subtropical gyre, the correlation coefficients were in the range 0.32-0.57. The correlation coefficients for the western and eastern Equatorial Pacific were relatively low (<0.36. These correlation coefficients were further interpreted in terms of the geographical distributions of dust sources, the transport pathways, the dust deposition, the nutrient conditions of oceans, and the probability of dust storms reaching the seas.

  11. Investigation of coal dust explosion hazard at the Nikola Tesla-A thermal power station

    Energy Technology Data Exchange (ETDEWEB)

    Golubovic, D

    1987-10-01

    Reports on investigations into coal dust explosion hazards in working places with high coal dust exposure, done in the Tesla-A thermal power station by Mining Institute of Belgrade specialists. Settled and floating coal dust concentrations were monitored for six months and samples analyzed for explosibility under lab conditions. Samples from transport and preparation facilities and the power station boiler house were taken. The entire plant was divided into 4 zones, depending on intensity of dust settlement and ventilation system. Coal dust generation varied from 0.3-65 g/min. Daily dust settlement ranged between 40 and 300 g/m/sup 2/. Total quantity of accumulated coal dust in the power plant ranged from 0.8-650 kg/day; 250 g/m/sup 3/ of coal dust may cause an explosion. Thus, a dangerous amount of coal dust, depending on work-site, will settle in 3.3.-21.8 days. Disturbance of settled dust may create explodable clouds. Details of measurements taken and data evaluation are included. 4 refs.

  12. Seasonal variations of radon concentrations in single-family houses with different sub-structures

    DEFF Research Database (Denmark)

    Majborn, B.

    1992-01-01

    Seasonal variations of indoor radon concentrations have been studied in 70 single-family houses selected according to the type of sub-structure and the type of soil underneath the house. Five categories of sub-structure were included - slab-on-grade, crawl space, basement, and combinations...... of basement with slab-on-grade or crawl space. Half of the houses are located on clayey till and the other half on glaciofluvial gravel. In each house radon was measured in a living room and a bedroom, in the basement if present, and in the crawl space if present and accessible. The measurements were made...... with track detectors on a quarterly basis throughout a year. For living rooms and bedrooms the seasonal variations range from being highly significant for the slab-on-grade houses to being insignificant for the crawl space houses. For basements and crawl spaces the geometric mean radon concentrations do...

  13. Measuring instrument for the determination of dust concentrations. [air filter with. beta. radiometric gage

    Energy Technology Data Exchange (ETDEWEB)

    Dresia, H; Spohr, F

    1975-05-22

    The measuring instrument enables a continuous determination of the dust concentration or total dust content in gases on the basis of the radiometric mass determination of dusts. The partial current method is employed, with the gas fetched through a filter cell with a topped intake by a suction pump. A filter band to take up the dust deposit is continuously driven through the filter cell. The filter point and the measuring point with a ..beta..-radionuclide and a detector are both inside the filter cell. The filter cell is sealed all around, at the entrance and exit of the filter band. The band itself acts as a seal. The filter band also has borders strengthened with, e.g., plastic strips which engage the drive. The widths of the slits are adjustable in height.

  14. Occurrence and levels of polybrominated diphenyl ethers (PBDEs) in house dust and hair samples from Northern Poland; an assessment of human exposure.

    Science.gov (United States)

    Król, Sylwia; Namieśnik, Jacek; Zabiegała, Bożena

    2014-09-01

    Polybrominated diphenyl ethers (PBDEs) are among most ubiquitous compounds to be found in indoor environment and ingestion of household dust is considered an important route of exposure to PBDEs, especially in toddlers and young children. The present work reported concentration levels of PBDE congeners (PBDE-28, -47, -99, -100, -153, -154, -183 and -209) in hair and dust samples from selected households from Northern Poland. The concentrations of PBDEs in dust ranged from human hair. PBDE-209 was reported the dominating congener. Two separated exposure scenarios (mean and 95th percentile) were used to provide a comprehensive overview of possible risks arising from ingestion of household dust. The estimated exposure to ∑PBDEs via ingestion of household dust varied from 21 to 92ngd(-1) in toddlers and from 3.7 to 20ngd(-1) in adults. By comparison of correlation between the concentrations of PBDEs in paired hair and dust samples the present work also investigated the possibility of use of hair for reflecting the actual exposure to PBDEs in humans. Finally the possible uncertainties associated with exposure assessment were investigated in the present study. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Maternal house dust mite exposure during pregnancy enhances severity of house dust mite-induced asthma in murine offspring.

    Science.gov (United States)

    Richgels, Phoebe K; Yamani, Amnah; Chougnet, Claire A; Lewkowich, Ian P

    2017-11-01

    Atopic status of the mother and maternal exposure to environmental factors are associated with increased asthma risk. Moreover, animal models demonstrate that exposure to allergens in strongly sensitized mothers influences offspring asthma development, suggesting that in utero exposures can influence offspring asthma. However, it is unclear whether maternal exposure to common human allergens such as house dust mite (HDM), in the absence of additional adjuvants, influences offspring asthma development. We sought to determine whether maternal HDM exposure influences asthma development in offspring. Pregnant female mice were exposed to PBS or HDM during pregnancy. Using offspring of PBS- or HDM-exposed mothers, the magnitude of HDM or Aspergillus fumigatus (AF) extract-induced airway hyperresponsiveness (AHR), airway inflammation, immunoglobulin production, T H 2-associated cytokine synthesis, and pulmonary dendritic cell activity was assessed. Compared with offspring of PBS-exposed mothers, offspring of HDM-exposed mothers demonstrate increased AHR, airway inflammation, T H 2 cytokine production, and immunoglobulin levels and a modest decrease in the phagocytic capacity of pulmonary macrophage populations following HDM exposure. Increased sensitivity to AF-induced airway disease was not observed. Offspring of HDM-exposed B-cell-deficient mothers also demonstrated increased HDM-induced AHR, suggesting that transfer of maternal immunoglobulins is not required. Our data demonstrate that maternal exposure to HDM during pregnancy increases asthma sensitivity in offspring in an HDM-specific manner, suggesting that vertical transmission of maternal immune responses may be involved. These findings have important implications for regulation of asthma risk, and suggest that exposure to HDM in the developed world may have underappreciated influences on the overall prevalence of allergic asthma. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by

  16. [Dust concentration analysis in non-coal mining. Exposure evaluation based on measurements performed by occupational hygiene laboratories in the years 2001-2005 in Poland].

    Science.gov (United States)

    Bujak-Pietrek, Stella; Mikołajczyk, Urszula; Szadkowska-Stańczyk, Irena

    2011-01-01

    Non-coal mining includes the extraction of materials for construction (stone, gravel, sand and clay), chemical industry (salt and sulfur), metallurgy (metal ores, uranium and thorium) and other mining and quarrying. Regardless of the type of mining company one of the most common health hazards in this sector is exposure to high concentrations of dust occurring during the extraction of materials. Such activities as drilling, use of blasting agents, processing of raw material, its transportation and loading are the source of large amounts of dust containing crystalline silica. Data on exposure to dust, collected by industrial hygiene laboratories on the basis of dust concentration measurements in the work environment, were obtained from the sanitary inspection service. The analysis of dust concentrations at workplaces in non-coal mining covered the years 2001-2005. The average concentration of inhalable and respirable dust and the degree of results dispersion at workposts in different branches of non-coal mining (according to NACE rev1.1) were evaluated. Also there was estimated the percentage of surveys indicating dust concentrations above hygiene standards. Almost 5000 measurements of dust concentrations were performed in the years under study. The highest concentration of inhalable dust was noted for the production of salt (5.51 mg/m3), other mining and quarrying (4.30 mg/m3) and quarrying of slate (3.77 mg/m3). For respirable dust the highest concentrations were noted in other mining and quarrying (1.10 mg/m3), quarrying of slate (1.09 mg/m3) and quarrying of stone (0.81 mg/m3). Exposure to high concentrations of dust during the extraction of non-carbon is still an important hazard to human health. Almost for all workposts under study the excess of hygiene standards were observed.

  17. Cat, dog and house dust mite allergen levels on children's soft toys.

    Science.gov (United States)

    Wu, Francis Fu-Sheng; Wu, Mei-Wen; Ting, Ming-Hui; Crane, Julian; Siebers, Rob

    2014-02-01

    Children's soft toys are known to harbour house dust mite (HDM) allergens, but little is known whether they harbour cat or dog allergens. The objective of the study was to measure cat (Fel d 1), dog (Can f 1) and HDM allergens on children's soft toys. Dust was collected from 40 children's soft toys and their mattresses. Data were collected on pet ownership. Dust samples were analysed for Fel d 1, Can f 1, Der p 1 and Der f 1 by enzyme-linked immunosorbent assay (ELISA) and results are expressed as median levels with inter-quartile ranges. Thirty-five (87.5%) soft toys had detectable Fel d 1 levels (median: 0.73 µg/g; inter-quartile range: 0.26-2.56 µg/g) while 34 (85%) had detectable Can f 1 levels (1.20 µg/g; 0.53-2.68). Correspondingly, 32 (80%) mattresses had detectable Fel d 1 levels (0.18 µg/g, 0.07-1.01) while 34 (85%) had detectable Can f 1 levels (0.50 µg/g; 0.33-1.06). All mattresses and soft toys had detectable HDM allergen (Der p 1 + Der f 1) levels with soft toys containing about three times higher levels than mattresses. In homes with cats (n = 10) Fel d 1 levels were higher on soft toys than homes without cats (2.49 versus 0.48 µg/g; p = 0.0009). In homes with dogs (n = 25) Can f 1 levels were generally higher on soft toys (1.38 versus 0.63 µg/g; p = 0.10). This study has shown that soft toys can harbour cat and dog allergen as well as HDM allergens, some with very high levels. Cat and dog ownership resulted in higher Fel d 1 and Can f 1 levels on soft toys and mattresses. The levels of Fel d 1, Can f 1 and HDM allergens on soft toys could be of importance to sensitized asthmatic children.

  18. Concentrations and size distribution of inhalable and respirable dust among sugar industry workers: a pilot study in Khon Kaen, Thailand.

    Science.gov (United States)

    Sakunkoo, Pornpun; Chaiear, Naesinee; Chaikittiporn, Chalermchai; Sadhra, Steven

    2011-11-01

    There has been very limited information regarding bagasse exposure among workers in sugar industries as well as on health outcomes. The authors determined the occupational exposure of sugar industry workers in Khon Kaen to airborne bagasse dust. The size of the bagasse dust ranged from 0.08 to 9 µm with the highest size concentration of 2.1 to 4.7 µm. The most common size had a geometric mean diameter of 5.2 µm, with a mass concentration of 6.89 mg/m(3)/log µm. The highest mean values of inhalable and respirable dust were found to be 9.29 mg/m(3) from February to April in bagasse storage, 5.12 mg/m(3) from May to September, and 4.12 mg/m(3) from October to January. Inhalable dust concentrations were 0.33, 0.47, and 0.41 mg/m(3), respectively. Workers are likely to be exposed to high concentrations of bagasse dust and are at risk of respiratory diseases. Preventive measures, both in the form of engineering designs and personal protective devices, should be implemented.

  19. African dust outbreaks over the Mediterranean Basin during 2001-2011: concentrations, phenomenology and trends

    Science.gov (United States)

    Pey, Jorge; Querol, Xavier; Alastuey, Andres; Forastiere, Franceso; Stafoggia, Massimo

    2013-04-01

    Concentrations, phenomenology and trends of African dust outbreaks over the whole Mediterranean Basin werestudied on an 11-year period (2001-2011). This work has been performed in the context of the MED-PARTICLES (LIFE programme, EU) project, devoted to quantify short-term health effects of particulate matter over the Mediterranean region by distinguishing different particle sizes, chemical components and sources, with emphasis in the effects of African dust. In order to evaluate conduct this investigation, PM10 data from 19 regional and suburban background sites West to East in the Mediterranean area were compiled. After identifying the daily occurrence of African dust outbreaks, a methodology for estimating natural dust contributions on daily PM10 concentrations was applied. Our findings point out that African dust outbreaks are sensibly more frequent in southern sitesacross the Mediterranean, from 30 to 37 % of the annual days, whereas they occur less than 20% of the annual days in northern sites. The central Mediterranean emerges as a transitional area, with slightly higher frequency of dust episodes in its lower extreme when compared to similar latitudinal positions in western and eastern sides of the Basin. A decreasing south to north gradient of African dust contribution to PM10, driven by the latitudinal position of the monitoring sites at least 25°E westwards across the Basin,is patent across the Mediterranean. From 25°E eastwards, higher annual dust contributions are encountered due to the elevated annual occurrence of severe episodesof dust but also because of inputs from Middle Eastern deserts. Concerning seasonality patterns and intensity characteristics, a clear summer prevalence is observed in the western part, with low occurrence of severe episodes (daily dust averages over 100 µg m-3 in PM10); no seasonal trend is detected in the central region, with moderate-intensity episodes; and significantly higher contributions are common in autumn

  20. Polybrominated diphenyl ethers and “novel” brominated flame retardants in floor and elevated surface house dust from Iraq: Implications for human exposure assessment

    Directory of Open Access Journals (Sweden)

    Layla Salih Al-Omran

    2016-03-01

    Full Text Available Concentrations of polybrominated diphenyl ethers (PBDEs and selected novel brominated flame retardants (NBFRs were measured in indoor dust from the living areas of 18 homes in Basrah, Iraq. This is the first report of contamination of the Iraqi environment with these chemicals. To evaluate the implications for human exposure, samples were collected from both the floor and from elevated surfaces like tables, shelves and chairs. When normalised for the organic carbon content of the dust sample, concentrations in elevated surface dust of BDE-99, BDE-209, pentabromoethylbenzene (PBEB, bis (2-ethylhexyl 3,4,5,6-tetrabromophthalate (BEH-TEBP, and decabromodiphenylethane (DBDPE exceeded significantly (p < 0.05 those in floor dust from the same rooms. This suggests that previous studies that base estimates of adult exposure via dust ingestion on floor dust, may underestimate exposure. Such underestimation is less likely for toddlers who are far more likely to ingest floor dust. Concentrations of PBDEs and NBFRs in indoor dust from Basrah, Iraq are at the lower end of levels reported elsewhere. The PBDE contamination pattern in our samples suggests that use in Iraq of the Deca-BDE formulation, exceeds substantially that of Penta-BDE, but that use of the Octa-BDE formulation has been higher in Iraq than in some other regions. Reassuringly, our estimates of exposure to our target BFRs via dust ingestion for the Iraqi population fall well below the relevant health-based limit values.

  1. Comparison of Respirable Mass Concentrations Measured by a Personal Dust Monitor and a Personal DataRAM to Gravimetric Measurements.

    Science.gov (United States)

    Halterman, Andrew; Sousan, Sinan; Peters, Thomas M

    2017-12-15

    In 2016, the Mine Safety and Health Administration required the use of continuous monitors to measure respirable dust in mines and better protect miner health. The Personal Dust Monitor, PDM3700, has met stringent performance criteria for this purpose. In a laboratory study, respirable mass concentrations measured with the PDM3700 and a photometer (personal DataRam, pDR-1500) were compared to those measured gravimetrically for five aerosols of varying refractive index and density (diesel exhaust fume, welding fume, coal dust, Arizona road dust (ARD), and salt [NaCl] aerosol) at target concentrations of 0.38, 0.75, and 1.5 mg m-3. For all aerosols except coal dust, strong, near-one-to-one, linear relationships were observed between mass concentrations measured with the PDM3700 and gravimetrically (diesel fume, slope = 0.99, R2 = 0.99; ARD, slope = 0.98, R2 = 0.99; and NaCl, slope = 0.95, R2 = 0.99). The slope deviated substantially from unity for coal dust (slope = 0.55; R2 = 0.99). Linear relationships were also observed between mass concentrations measured with the pDR-1500 and gravimetrically, but one-to-one behavior was not exhibited (diesel fume, slope = 0.23, R2 = 0.76; coal dust, slope = 0.54, R2 = 0.99; ARD, slope = 0.61, R2 = 0.99; NaCl, slope = 1.14, R2 = 0.98). Unlike the pDR-1500, mass concentrations measured with the PDM3700 appear independent of refractive index and density, suggesting that it could have applications in a variety of occupational settings. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  2. Evaluation of the Role of IgE Responses to Der p 1 and Der p 2 in Chinese House Dust Mite-Allergic Patients

    NARCIS (Netherlands)

    Wang, Hui-Ying; Gao, Zhong-Shan; Zhou, Xiang; Dai, Yu; Yao, Wo; Zhang, Xiao-Feng; Yang, Zhao-Wei; Wu, Shan-Dong; Yu, Chao-Hui; Yang, Xu-Yan; van Ree, Ronald

    2015-01-01

    The role of specific IgE (sIgE) against Der p 1 and Der p 2 in Chinese patients with house dust mite (HDM) allergy has not yet been well investigated. One hundred patients were enrolled, based on sensitization and doctor-diagnosed allergy to HDM. Questionnaires were administered to document

  3. Is there a threshold concentration of cat allergen exposure on respiratory symptoms in adults?

    NARCIS (Netherlands)

    Chen, C.M.; Thiering, E.; Zock, J.P.; Villani, S.; Olivieri, M.; Modig, L.; Jarvis, D.; Norbäck, D.; Verlato, G.; Heinrich, J.

    2015-01-01

    Background and Objective: Cat allergen concentrations higher than 8 μg/g in settled house dust, have been suggested to provoke exacerbation of allergic respiratory symptoms. However, whether the 8μg/g of indoor cat allergen concentration is indeed the minimal exposure required for triggering the

  4. Radioactive dust concentration around the Ranger uranium mine

    International Nuclear Information System (INIS)

    Kavasnicka, Jiri.

    1988-07-01

    Environmental dust sampling and wind direction/velocity monitory were carried out between July and November 1987 at five points around the Ranger Uranium Mines project near Jabiru, Northern Territory. The measured radioactive dust alpha activities in the air were used to calculate the radioactive dust source-term and develop a site-specific air dispersion model which takes the depletion of the dust plume into account. The above model was used to estimate the effective committed dose equivalent as 15 μSv/year to children in Jabiru East. This corresponds to an increase of 2.6 x 10 -4 Bq. m -3 in the annual average dust alpha activity above the natural background. The dose to the children in Jabiru is about 5 μSv/year, so that the critical group of the public is in Jabiru East. 12 refs., 11 tabs., 2 maps

  5. Inactivation of dust mites, dust mite allergen, and mold from carpet.

    Science.gov (United States)

    Ong, Kee-Hean; Lewis, Roger D; Dixit, Anupma; MacDonald, Maureen; Yang, Mingan; Qian, Zhengmin

    2014-01-01

    Carpet is known to be a reservoir for biological contaminants, such as dust mites, dust mite allergen, and mold, if it is not kept clean. The accumulation of these contaminants in carpet might trigger allergies or asthma symptoms in both children and adults. The purpose of this study is to compare methods for removal of dust mites, dust mite allergens, and mold from carpet. Carpets were artificially worn to simulate 1 to 2 years of wear in a four-person household. The worn carpets were inoculated together with a common indoor mold (Cladosporium species) and house dust mites and incubated for 6 weeks to allow time for dust mite growth on the carpet. The carpets were randomly assigned to one of the four treatment groups. Available treatment regimens for controlling carpet contaminants were evaluated through a literature review and experimentation. Four moderately low-hazard, nondestructive methods were selected as treatments: vacuuming, steam-vapor, Neem oil (a natural tree extract), and benzalkonium chloride (a quaternary ammonium compound). Steam vapor treatment demonstrated the greatest dust mite population reduction (p 0.05) for both physical and chemical methods. The steam-vapor treatment effectively killed dust mites and denatured dust mite allergen in the laboratory environment.

  6. Molecular, Structural and Immunological Characterization of Der p 18, a Chitinase-Like House Dust Mite Allergen.

    Directory of Open Access Journals (Sweden)

    Yvonne Resch

    Full Text Available The house dust mite (HDM allergen Der p 18 belongs to the glycoside hydrolase family 18 chitinases. The relevance of Der p 18 for house dust mite allergic patients has only been partly investigated.To perform a detailed characterization of Der p 18 on a molecular, structural and immunological level.Der p 18 was expressed in E. coli, purified to homogeneity, tested for chitin-binding activity and its secondary structure was analyzed by circular dichroism. Der p 18-specific IgG antibodies were produced in rabbits to localize the allergen in mites using immunogold electron microscopy and to search for cross-reactive allergens in other allergen sources (i.e. mites, crustacea, mollusca and insects. IgE reactivity of rDer p 18 was tested with sera from clinically well characterized HDM-allergic patients (n = 98 and its allergenic activity was analyzed in basophil activation experiments.Recombinant Der p 18 was expressed and purified as a folded, biologically active protein. It shows weak chitin-binding activity and partial cross-reactivity with Der f 18 from D. farinae but not with proteins from the other tested allergen sources. The allergen was mainly localized in the peritrophic matrix of the HDM gut and to a lower extent in fecal pellets. Der p 18 reacted with IgE from 10% of mite allergic patients from Austria and showed allergenic activity when tested for basophil activation in Der p 18-sensitized patients.Der p 18 is a rather genus-specific minor allergen with weak chitin-binding activity but exhibits allergenic activity and therefore should be included in diagnostic test panels for HDM allergy.

  7. Concentrations of polycyclic aromatic hydrocarbons in resuspendable fraction of settled bus dust and its implications for human exposure.

    Science.gov (United States)

    Gao, Peng; Liu, Sa; Feng, Yujie; Lin, Nan; Lu, Binyu; Zhang, Zhaohan; Cui, Fuyi; Xing, Baoshan; Hammond, S Katharine

    2015-03-01

    This preliminary study measured Polycyclic Aromatic Hydrocarbons (PAHs) concentrations in the resuspendable fraction of settled dust on 39 bus lines, to evaluate the impact of engine type (gasoline and compressed natural gas) on exposure for commuters and drivers. Benzo(b)fluoranthene(BbF) was the predominant PAH in resuspendable fraction of settled bus dust. The concentration of total PAHs was 92.90 ± 116.00 μg/g (range: 0.57-410) in gasoline buses and 3.97 ± 1.81 (range: 2.01-9.47) in compressed natural gas (CNG) buses. Based on Benzo[a]pyrene (BaP) equivalent concentrations for the sum of 16 PAHs, the average daily dose (ADD) via dust ingestion and dermal contact was calculated. The ADD of PAHs was higher for commuters and drivers in gasoline-powered buses than in buses using CNG buses. For both short and long duration journeys, young commuters were exposed to higher levels of PAHs via dust ingestion and dermal contact than adult commuters. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Influence of radon-daughter exposure rate and uranium ore dust concentration on occurrence of lung tumors

    International Nuclear Information System (INIS)

    Cross, F.T.; Palmer, R.F.; Busch, R.H.

    1980-01-01

    Groups of male SPF Wistar rats were exposed concurrently to several levels of radon daughters and uranium ore dust to study the effect of these variables on pulmonary disease states. Clinical pathology data at 1 yr postexposure indicate no significant differences among exposed animals when compared with controls. Preliminary histopathologic data suggest a trend toward increasing lung tumor risk as the exposure rate is decreased (constant total dose), but the differences are not statistically significant at the 0.05 level. A similar trend occurs with decrease in ore dust concentration (except for the 2560-WLM exposure group), but these differences are also not significant at the 0.05 level. The tumor risk is significantly (0.05 level) increased as the exposure level increases from approximately 320 and 640 WLM to 2560 WLM at the high ore dust concentration

  9. An analysis of factors affecting the high radon concentration in different types of houses

    Directory of Open Access Journals (Sweden)

    Gulan Ljiljana

    2017-01-01

    Full Text Available This paper presents an analysis of indoor radon measurements carried out in municipality of Zubin Potok, northwestern part of Kosovo and Metohija. Annual measurements in two rooms of each house were performed by solid state nuclear track detectors commercially known as Gammadata. Average indoor radon concentration in different type of houses varied from 29-326 Bq/m3. A different year of house's construction including various types of building materials were selected for survey. A detail analysis showed that the differences in radon concentration occur between various building materials used for construction, flooring level, type of room and behavior of inhabitants. It was found that building materials in some houses contribute additionally to indoor radon.

  10. The spatial concentration of dust emissions measured by using 3D scanning lidar in the open storage yards of steel-making company

    Science.gov (United States)

    Chiang, Chih-Wei; Chiang, Hong-Wei; Chou, Huann-Ming; Sun, Shu-Huang; Lee, Jiann-Shen

    2017-06-01

    The wind-blown dust emissions frequently occur in the open storage yards of steel-making companies. Tracking the dust source and monitoring their dispersion are rather difficult. This type of open-air storage yards poses many environmental hazards. The 3-D scanning lidar system is effective in environmental monitoring (e.g., dust) with high temporal and spatial resolution, which is lacking in traditional ground-based measurement. The objective of this paper is to make an attempt for the flux estimation of dust concentration by using lidar system. Further, we investigate the dynamical process of dust and their relationship with local air quality monitoring data. The results show that the material storage erosion by wind ( 3.6 m/s) could cause dust to elevate up to 20m height above the material storage, and produces the flux of dust around 674 mg/s. The flux of dust is proportional to the dust mass concentration (PM10) measured by commercial ambient particular monitors.

  11. The role of dust storms in total atmospheric particle concentrations at two sites in the western U.S.

    Science.gov (United States)

    Neff, Jason C.; Reynolds, Richard L.; Munson, Seth M.; Fernandez, Daniel; Belnap, Jayne

    2013-01-01

    Mineral aerosols are produced during the erosion of soils by wind and are a common source of particles (dust) in arid and semiarid regions. The size of these particles varies widely from less than 2 µm to larger particles that can exceed 50 µm in diameter. In this study, we present two continuous records of total suspended particle (TSP) concentrations at sites in Mesa Verde and Canyonlands National Parks in Colorado and Utah, USA, respectively, and compare those values to measurements of fine and coarse particle concentrations made from nearby samplers. Average annual concentrations of TSP at Mesa Verde were 90 µg m−3 in 2011 and at Canyonlands were 171 µg m−3 in 2009, 113 µg m−3 in 2010, and 134 µg m−3 in 2011. In comparison, annual concentrations of fine (diameter of 2.5 µm and below) and coarse (2.5–10 µm diameter) particles at these sites were below 10 µg m−3 in all years. The high concentrations of TSP appear to be the result of regional dust storms with elevated concentrations of particles greater than 10 µm in diameter. These conditions regularly occur from spring through fall with 2 week mean TSP periodically in excess of 200 µg m−3. Measurement of particles on filters indicates that the median particle size varies between approximately 10 µm in winter and 40 µm during the spring. These persistently elevated concentrations of large particles indicate that regional dust emission as dust storms and events are important determinants of air quality in this region.

  12. Factors influencing indoor PM2.5 concentration in rural houses of northern China

    Science.gov (United States)

    Zhang, Xueyan; Chen, Bin

    2018-02-01

    In traditional houses in rural areas of Northern China, most traditional heating systems, heated by mini-stove in the kitchen, usually take agricultural residues as fuels resources. Besides, burning cave under the ground-floor of a rural house is also widely used. The higher PM2.5 concentration is crisis for human health. In this study, PM2.5 concentration, temperature, relative humidity inside and outside the houses have been measured, moreover the factors impact on I/O rate coefficient has been discussed. The results show that the I/O rate coefficient in the evening is 2.5 times greater than the I/O rate coefficient in the daytime. I/O rate coefficient of PM2.5 concentration is positive related to air temperature difference between indoor and outdoor. In addition, the impact of outdoor wind speed and predominant wind direction on the PM2.5 emission has been studied.

  13. Characterizing temporal changes of agricultural particulate matter number concentrations

    Science.gov (United States)

    Docekal, G. P.; Mahmood, R.; Larkin, G. P.; Silva, P. J.

    2017-12-01

    It is widely accepted among literature that particulate matter (PM) are of detriment to human health and the environment as a whole. These effects can vary depending on the particle size. This study examines PM size distributions and number concentrations at a poultry house. Despite much literature on PM concentrations at agricultural facilities, few studies have looked at the size distribution of particles at such facilities from the nucleation up through the coarse mode. Two optical particle counters (OPCs) were placed, one inside of a chicken house, and one on the outside of an exhaust fan to determine particle size distributions. In addition, a scanning mobility particle sizer (SMPS) and aerodynamic particle sizer (APS) sampled poultry house particles to give sizing information from a full size range of 10 nm - 20 mm. The data collected show several different types of events where observed size distributions changed. While some of these are due to expected dust generation events producing coarse mode particles, others suggest particle nucleation and accumulation events at the smaller size ranges that also occurred. The data suggest that agricultural facilities have an impact one the presence of PM in the environment beyond just generation of coarse mode dust. Data for different types of size distribution changes observed will be discussed.

  14. Bee Venom Phospholipase A2 Alleviate House Dust Mite-Induced Atopic Dermatitis-Like Skin Lesions by the CD206 Mannose Receptor

    OpenAIRE

    Dasom Shin; Won Choi; Hyunsu Bae

    2018-01-01

    Atopic dermatitis (AD) is a chronic inflammatory skin disease characterized by highly pruritic, erythematous, and eczematous skin plaques. We previously reported that phospholipase A2 (PLA2) derived from bee venom alleviates AD-like skin lesions induced by 2,4-dinitrochlorobenzene (DNCB) and house dust mite extract (Dermatophagoides farinae extract, DFE) in a murine model. However, the underlying mechanisms of PLA2 action in actopic dermatitis remain unclear. In this study, we showed that PLA...

  15. Concentrations of polycyclic aromatic hydrocarbons in resuspendable fraction of settled bus dust and its implications for human exposure

    International Nuclear Information System (INIS)

    Gao, Peng; Liu, Sa; Feng, Yujie; Lin, Nan; Lu, Binyu; Zhang, Zhaohan; Cui, Fuyi; Xing, Baoshan; Hammond, S. Katharine

    2015-01-01

    This preliminary study measured Polycyclic Aromatic Hydrocarbons (PAHs) concentrations in the resuspendable fraction of settled dust on 39 bus lines, to evaluate the impact of engine type (gasoline and compressed natural gas) on exposure for commuters and drivers. Benzo(b)fluoranthene(BbF) was the predominant PAH in resuspendable fraction of settled bus dust. The concentration of total PAHs was 92.90 ± 116.00 μg/g (range: 0.57–410) in gasoline buses and 3.97 ± 1.81 (range: 2.01–9.47) in compressed natural gas (CNG) buses. Based on Benzo[a]pyrene (BaP) equivalent concentrations for the sum of 16 PAHs, the average daily dose (ADD) via dust ingestion and dermal contact was calculated. The ADD of PAHs was higher for commuters and drivers in gasoline-powered buses than in buses using CNG buses. For both short and long duration journeys, young commuters were exposed to higher levels of PAHs via dust ingestion and dermal contact than adult commuters. - Highlights: • Resuspendable fraction of settled dust from microenvironment of buses in Harbin monitored for PAHs exposure assessment. • Higher levels of PAHs pollutants at gasoline-powered buses than at compressed natural gas-powered buses. • Non-occupational and occupational exposures in the microenvironment of buses are assessed. - Occupational and non-occupational exposure to PAHs from the microenvironment of bus

  16. Influence of ventilation strategies on indoor radon concentrations based on a semiempirical model for Florida-style houses

    International Nuclear Information System (INIS)

    Hintenlang, D.E.; Al-Ahmady, K.K.

    1994-01-01

    Measurements in a full-scale experimental facility are used to benchmark a semiempirical model for predicting indoor radon concentrations for Florida-style houses built using slab-on-grade construction. The model is developed to provide time-averaged indoor radon concentrations from quantitative relationships between the time-dependent radon entry and elimination mechanisms that have been demonstrated to be important for this style of residential construction. The model successfully predicts indoor radon concentrations in the research structure for several pressure and ventilation conditions. Parametric studies using the model illustrate how different ventilation strategies affect indoor radon concentrations. It is demonstrated that increasing house ventilation rates by increasing the effective leakage area of the house shell does not reduce indoor radon concentrations as effectively as increasing house ventilation rates by controlled duct ventilation associated with the heating, ventilating, and air conditioning system. The latter strategy provides the potential to minimize indoor radon concentrations while providing positive control over the quality of infiltration air. 9 refs., 5 figs

  17. Cow allergen (Bos d2) and endotoxin concentrations are higher in the settled dust of homes proximate to industrial-scale dairy operations.

    Science.gov (United States)

    Williams, D' Ann L; McCormack, Meredith C; Matsui, Elizabeth C; Diette, Gregory B; McKenzie, Shawn E; Geyh, Alison S; Breysse, Patrick N

    2016-01-01

    Airborne contaminants produced by industrial agricultural facilities contain chemical and biological compounds that can impact the health of residents living in close proximity. Settled dust can be a reservoir for these contaminants and can influence long-term exposures. In this study, we sampled the indoor- and outdoor-settled dust from 40 homes that varied in proximity to industrial-scale dairies (ISD; industrial-scale dairy, a term used in this paper to describe a large dairy farm and adjacent waste sprayfields, concentrated animal feeding operation or animal feeding operation, that uses industrial processes) in the Yakima Valley, Washington. We analyzed settled dust samples for cow allergen (Bos d2, a cow allergen associated with dander, hair, sweat and urine, it is a member of the lipocalin family of allergens associated with mammals), mouse allergen (Mus m1; major mouse allergen, a mouse urinary allergen, in the lipocalin family), dust mite allergens (Der p1 (Dermatophagoides pteronissinus 1) and Der f1 (Dermatophagoides farinae 1)), and endotoxin (a component of the cell walls of gram negative bacteria, lipopolysaccharide, which can be found in air and dust and can produce a strong inflammatory response). A concentration gradient was observed for Bos d2 and endotoxin measured in outdoor-settled dust samples based on proximity to ISD. Indoor-settled dust concentrations of Bos d2 and endotoxin were also highest in proximal homes. While the associated health effects of exposure to cow allergen in settled dust is unknown, endotoxin at concentrations observed in these proximal homes (100 EU/mg) has been associated with increased negative respiratory health effects. These findings document that biological contaminants emitted from ISDs are elevated in indoor- and outdoor-settled dust samples at homes close to these facilities and extend to as much as three miles (4.8 km) away.

  18. Energy savings in dust collector plants of bag house filter type. Phase 1 - Literature study; Energieffektivisering av anlaeggningar foer stoftrening med slangfilter. Etapp 1-Litteraturstudie

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Lars; Wikman, Karin; Berg, Magnus [AaF-Energi and Miljoe AB, Stockholm (Sweden)

    2004-01-01

    The largest energy demands in connection with the operation of bag house filters are the electric energy consumption for the fans, securing the flow of flue gas through the filter, and the electric energy consumption when producing the pressurized air (compressors or high pressure fans). Considering the significantly increased fan work when having a non-optimised cleaning of the filters, it seems justified to investigate the possibilities to minimise the unnecessary pressure drop. There is also a saving potential in the filter cleaning process, which otherwise may cost an unacceptable amount of pressurized air or other energy. The main purpose of this work is to develop methods to optimize the operation of bag house filters, which is started up with this report containing a follow-up of what has been done in Denmark and a confirmation of the technology status. In the next step, a case study where two-three plants are examined more in detail is suggested followed by a potential study to estimate the total energy saving potential in Sweden. Dust precipitation with bag house filters is basically a rather simple technique, which has existed in flue gas cleaning for about 50 years. From the literature study it can be established that there has been no revolutionary development in the field, but there are some work being done mainly to introduce new filter material but also to optimise the use of bag house filters with new computer based control systems. The largest potential of energy saving prevails if the filter from the beginning is overloaded, which usually is the case. The reason for overload may be a too large volume flow in relation to the filter area, that the dust has penetrated and blocked the filter, a defective filter cleaning process or that wrong filter material has been chosen. In Denmark a study has been made with the purpose to investigate the possibilities to optimise the energy consumption for bag house filters. For the three plants studied, an

  19. ANALYSIS OF SOIL AND DUST SAMPLES FOR POLYCHLORINATED BIPHENYLS BY ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

    Science.gov (United States)

    An inhibition enzyme-linked immunosorbent assay (ELISA) was used to determine polychlorinated biphenyls (PCBs) in house dust and soil. Soil and house dust samples were analyzed for PCB by both gas chromatography/electron capture detection (GC/ECD) and ELISA methods. A correlati...

  20. Relation between residential radon concentrations and housing characteristics. The Cracow study

    International Nuclear Information System (INIS)

    Jedrychowski, W.; Flak, E.; Wesolowski, J.; Liu Kaishen

    1995-01-01

    The survey on indoor radon exposure was undertaken to explain whether the excess in lung cancer deaths in the Cracow city center may be attributed to this particular exposure. A total of 310 detectors was placed in households randomly chosen from three homogeneous strata of residential buildings. The first stratum included houses in the old city center constructed predominantly from stone bricks. The second stratum covered the city area with big apartment condominiums built from concrete blocks. The third stratum consisted of single family houses located in a suburban area. From each of these residency strata a random sample of an equal number of households was chosen, and the radon detectors were placed in households located at various levels of the buildings. The three-month radon sampling data were used to determine the distribution of various levels of radon in the households. In the measurement of radon exposure, Landauer α-track samplers were used. The data collected show that the type of building was the best single predictor of indoor radon concentrations. Other variables found to be associated significantly with indoor concentrations were the household level in the building and the house age. In general, residences with concrete slabs and dwellings with rarely-opened windows were found to have slightly higher radon concentrations. (author) 2 tabs., 15 refs

  1. Experimental human exposure to inhaled grain dust and ammonia: towards a model of concentrated animal feeding operations.

    Science.gov (United States)

    Sigurdarson, Sigurdur T; O'Shaughnessy, Patrick T; Watt, Janet A; Kline, Joel N

    2004-10-01

    Ammonia and endotoxin-rich dust are present in high concentrations in swine confinement facilities; exposure to this environment is linked to workers' respiratory problems. We hypothesized that experimental exposure to ammonia and dust would impair pulmonary function, and that these exposures would be synergistic. We exposed six normal subjects and eight subjects with mild asthma to ammonia (16-25 ppm) and/or endotoxin-rich grain dust (4 mg/m3). Pulmonary function and exhaled NOx were measured before and after exposure. There was no significant change in pulmonary function in the normal subjects following any of the exposure conditions. Among asthmatics, a significant transient decrease in FEV1 was induced by grain dust, but was not altered by ammonia; increased bronchial hyperreactivity was also noted in this group. In a vulnerable population, exposure to grain dust results in transient airflow obstruction. Short-term exposure to ammonia does not increase this response.

  2. Measurements of radon concentrations in dwelling houses

    International Nuclear Information System (INIS)

    Birkholz, W.; Klink, T.

    1993-01-01

    Radon and its daughter products gain in importance in health protection and radiation safety. Especially in the southern region of Saxony radon concentrations in dwellings may be high by former silver and uranium mines. We found radon contents of about 20.000 Bq/m 3 in dwellings. To redevelop such houses it is necessary to know intrude path of radon. In present work we studied different measuring systems, active and passive detectors, short and long term integrating devices. By means of investigation of radon sources several redeveloping methods are rates as well from radiological as from civil engineering point of view. (author)

  3. Bee Venom Phospholipase A2 Ameliorates House Dust Mite Extract Induced Atopic Dermatitis Like Skin Lesions in Mice.

    Science.gov (United States)

    Jung, Kyung-Hwa; Baek, Hyunjung; Kang, Manho; Kim, Namsik; Lee, Seung Young; Bae, Hyunsu

    2017-02-18

    Atopic dermatitis (AD) is a biphasic inflammatory skin disease that is provoked by epidermal barrier defects, immune dysregulation, and increased skin infections. Previously, we have demonstrated that bvPLA2 evoked immune tolerance by inducing regulatory T cells (Treg), and thus alleviated Th2 dominant allergic asthma in mice. Here, we would like to determine whether treatment with bvPLA2 exacerbates the AD-like allergic inflammations induced by house dust mite extract (DFE) in a murine model. Epidermal thickness, immune cell infiltration, serum immunoglobulin, and cytokines were measured. Ear swelling, skin lesions, and the levels of total serum IgE and Th1/Th2 cytokines were elevated in DFE/DNCB-induced AD mice. Topical application of bvPLA2 elicited significant suppression of the increased AD symptoms, including ear thickness, serum IgE concentration, inflammatory cytokines, and histological changes. Furthermore, bvPLA2 treatment inhibited mast cell infiltration into the ear. On the other hand, Treg cell depletion abolished the anti-atopic effects of bvPLA2, suggesting that the effects of bvPLA2 depend on the existence of Tregs. Taken together, the results revealed that topical exposure to bvPLA2 aggravated atopic skin inflammation, suggesting that bvPLA2 might be a candidate for the treatment of AD.

  4. Depigmented and polymerised house dust mite allergoid: allergen content, induction of IgG4 and clinical response.

    Science.gov (United States)

    Gallego, M T; Iraola, V; Himly, M; Robinson, D S; Badiola, C; García-Robaina, J C; Briza, P; Carnés, J

    2010-01-01

    Polymerised allergenic extracts (allergoids) are commonly used in allergen immunotherapy. Clinical efficacy and safety of these extracts have been demonstrated. Recently, allergen sequences have been identified by mass spectrometry in depigmented and polymerised (Dpg-Pol) extracts. The objectives of this study were to investigate the presence of allergens in Dpg-Pol extracts of house dust mite and to analyze the immunological changes induced by these extracts in asthmatic patients enrolled in a double-blind, placebo-controlled study. Dpg-Pol extracts were manufactured and vaccines with a composition of 50% Dermatophagoides pteronyssinus and 50% D. farinae (100 HEPL/ml) were prepared. Allergen composition was analyzed by mass spectrometry. Patients with asthma and rhinoconjunctivitis were treated in a 1-year, double-blind, placebo-controlled, parallel-group study with 6 up-dosing and monthly maintenance injections. Specific IgE and IgG4 titres to D. pteronyssinus, Der p 1 and Der p 2 were measured in patients' sera using the CAP system and direct ELISA experiments. Sequences from the major allergens Der p 1 and Der p 2 and from other allergens were identified in native and Dpg-Pol extracts. There was a statistically significant increase in specific IgG4, a decrease in the ratio of IgE/IgG4 to D. pteronyssinus and a significant increase in specific IgG4 to Der p 1 and Der p 2 in the patients allotted to active treatment. The detection of allergen sequences suggests preservation of major and minor allergens in Dpg-Pol allergoids from house dust mites. Efficacy in asthma treatment and the increase in specific IgG4 seem to be associated with the presence of major allergens in Dpg-Pol allergen extracts. Copyright (c) 2010 S. Karger AG, Basel.

  5. Identification of historical lead sources in roof dust and recent lake sediments from an industrialized are: Indications from lead isotopes

    International Nuclear Information System (INIS)

    Chenhall, B.E.; Depers, A.M.; Jones, B.G.; Chiaradia, M.

    1997-01-01

    X-ray fluorescence and stable lead (Pb) isotopic analyses have been undertaken on dusts, known from microscopic investigation to contain significant quantities of industrially- and urban-derived particulate matter, present in the roof cavities of houses in the Illawarra region (N.S.W., Australia), with the objective of examining the historic record of Pb pollution. All investigated houses contained in excess of 250 μg g -1 Pb, with dwellings close to a copper smelter, in a large industrial complex including a major steelworks, containing higher (>2500 μg g -1 ) Pb concentrations. The isotopic composition in the dusts, expressed here as 206 Pb/ 204 Pb, is relatively constant at 17.0, irrespective of dwelling age or distance from the industrial complex. Contamination of the dusts by Pb sourced from paint cannot explain the isotopic uniformity of the dust samples. Isotopic modelling indicates that the dusts contain Pb derived from the copper smelter, gasoline-air Pb and a minor contribution from the steelworks. Isotopic calculations, together with records of particulate pollution emission, indicate a link between the Pb in roof dusts and Pb contamination of the near surface lagoonal sediments. Over the last five decades, atmospheric fallout of Pb-bearing particulate matter appears to have been the dominant pathway for addition of Pb to the lagoon and dwellings in the Illawarra region

  6. Indoor house pollution: appliance emissions and indoor ambient concentrations

    Energy Technology Data Exchange (ETDEWEB)

    Caceres, T [Univ. of Santiago, Chile; Soto, H; Lissi, E; Cisternas, R

    1983-01-01

    Emissions rates for CO, NO, NO/sub 2/ adn CH/sub 2/O from several unvented gas and kerosene heaters frequently employed in domestic heating have been measured. The indoor concentrations generated by these emissions are evaluated and compared to those determined in typical houses. It is found that both the predicted and measured values exceed the short term air quality standards accepted in most countries.

  7. Radon concentrations in residential housing in hiroshima and nagasaki

    International Nuclear Information System (INIS)

    Aoyama, Takashi; Radford, E.P.; Yonehara, Hidenori; Kato, Hiroo; Sakanoue, Masanobu.

    1993-05-01

    A survey of indoor radon ( 222 Rn) concentrations in Hiroshima and Nagasaki was carried out to assess the range of exposures expected among atomic-bomb survivors. Two hundred dwellings (100 from each city), chiefly of members of the Radiation Effects Research Foundation Life Span Study, were selected for this survey. We used two types of etched-track alpha-particle detectors: a Terradex detector (type SF) and an improved bare-track detector. Comparative measurements showed that although there was an adequate correlation between the values obtained using the two detectors, the geometric mean value for the bare-track detector was 45% lower than that for the Terradex detector. This difference was considered to be due to differences in the calibration methods and in the sensitivities of the detectors to thoron ( 220 Rn). The geometric mean values of the radon concentrations for 193 locations in Hiroshima and 192 locations in Nagasaki measured by Terradex SF detectors were 51.8 Bq/m 3 and 26.5 Bq/m 3 , respectively. The large difference is attributable to the different geological environments of the two cities. Factors correlating with the indoor radon concentrations were also studied. The geometric mean concentration was significantly higher in wooden houses with clay walls than in other types of house. This tendency was especially strong in Hiroshima. The difference between the estimated dose equivalents for exposure to radon decay products in dwellings in Hiroshima and Nagasaki during the last 30 years might amount to 0.8 Sv; however, no statistically significant difference was observed in lung-cancer mortality in the low-dose range in either city. Nevertheless, the indoor radon concentrations estimated in this survey could have a significant influence on the dose-response relationship for atomic-bomb exposure. (author)

  8. Bioavailability of House Dust Mite Allergens in Sublingual Allergy Tablets Is Highly Dependent on the Formulation.

    Science.gov (United States)

    Ohashi-Doi, Katsuyo; Kito, Hirokazu; Du, Weibin; Nakazawa, Hiroshi; Ipsen, Henrik; Gudmann, Pernille; Lund, Kaare

    2017-01-01

    In sublingual immunotherapy (SLIT), the immune system is addressed by solubilized allergen that interacts with immunocompetent cells of the oral mucosa, the efficiency of which is governed by 2 main factors of SLIT allergen bioavailability: the allergen concentration and the mucosal contact time. Recently, 3 house dust mite (HDM) SLIT tablets were developed that differ with regard to allergen content, nominal strength (maintenance doses: 6 SQ-HDM/10,000 Japanese Allergen Units [JAU], 12 SQ-HDM/ 20,000 JAU, and 300 IR/57,000 JAU), and formulation (freeze-dried/compressed). Here, the importance of the SLIT tablet formulation for HDM major allergen bioavailability is examined. The HDM major allergen content, tablet disintegration times, and allergen release kinetics were determined. Dissolution kinetics (allergen concentration vs. time) of Der f 1, Der p 1, and Der 2 were measured. Area under the curve (AUC) was used as a surrogate parameter for allergen bioavailability. The release of HDM major allergens from the freeze-dried tablets was complete after 30 s, while only partial release was achieved with the compressed tablets, even after prolonged dissolution. At 1 min, i.e., the recommended sublingual holding time for the freeze-dried tablets, the allergen bioavailability (AUC) of the compressed 300 IR/57,000 JAU tablet was 4.7-fold (Der f 1), 10.8-fold (Der p 1), and 23.6-fold (Der 2) lower than that of the freeze-dried 12 SQ-HDM/20,000 JAU tablet and similar to (Der f 1) and 5.3-fold (Der p 1) and 12.5-fold (Der 2) lower than that of the freeze-dried 6 SQ-HDM/10,000 JAU tablet. SLIT tablet allergen bioavailability depends highly on the tablet formulation. Only the fast-dissolving freeze-dried tablets provide maximal delivery of soluble allergens and achieve allergen concentrations that reflect the nominal tablet strengths within the recommended sublingual holding time. © 2017 S. Karger AG, Basel.

  9. Biological contaminants and house characteristics : an interim analysis of data from the PEI study

    Energy Technology Data Exchange (ETDEWEB)

    Onysko, D.M. [DMO Associates (Canada); Ruest, K. [Canada Mortgage and Housing Corp., Ottawa, ON (Canada); Lawton, M. [Morrison Hershfield Ltd., Ottawa, ON (Canada); Miller, D. [Carleton Univ., Ottawa, ON (Canada); Fraser, B. [Jacques Whitford and Associates Limited, Ottawa, ON (Canada); Dale, R. [Health Canada, Ottawa, ON (Canada); Kazimierz, K.F.

    2005-07-01

    This paper discussed the results of a joint study on housing conditions, biological exposure and the health of infants in Prince Edward Island (PEI). The study was a longitudinal cohort investigation of the exposure of infants to biological materials in their home environments. Possible associations between housing data, biological data, operational circumstances and relevant family life style information were presented. A methodology of the study was presented, in which a total of 366 dwellings with newborn infants were monitored over a period of 6 years. All tests and inspections were presented, as well as the nature of variables in the study. House investigations included the following: housing and operational characteristics; variables related to the measure of molds in the air; mold areas as determined by visual inspection; the presence/absence of visible molds; past wetting events; and concentrations of endotoxins, ergosterol and allergens in various air and settled dust samples. It was concluded that there was support for the presumption that some housing characteristics were related to factors that may influence the health of occupants and their children. Moisture related concerns dominated the experimental design. Details of the following housing characteristics were summarized: ground moisture source coupling; operation of the residence by the occupant; analysis of dust samples; visible molds; and wetting events. It was concluded that further work is needed to review the final database in order to further correlate studies with the health of newborns who lived in the houses studied. 3 refs., 8 tabs., 4 figs.

  10. Lead dust in broken hill homes--a potential hazard for young children?

    Science.gov (United States)

    Boreland, F; Lyle, D M; Wlodarczyk, J; Balding, W A; Reddan, S

    2002-01-01

    To determine the potential hazard posed by indoor lead dust to young children in Broken Hill, a silver-lead-zinc mining town in outback Australia, and the degree to which lead flux is influenced by factors such as geographical location, house construction type and condition. 116 homes were selected and 93 (80%) studied from 10 localities in Broken Hill during the spring of 1995. Lead flux was measured using 85 mm diameter polystyrene petri dishes. Dishes were placed in four rooms of each house to collect dust over a six-to-eight-week period. Data on the location, condition and construction type of each house were recorded. Multiple linear regression was used to determine predictors of lead flux. Flux data were log transformed for the analysis. Average household lead flux varied nearly seven-fold across districts from a low of 166 (distant from the mines), to a high of 1,104 microg/m2/30-day period (adjacent to the mines). Houses that were 'adequately sealed' had 2.9 times the lead flux, and 'poorly sealed' houses 4.3 times the flux, of 'very well sealed' houses. Construction material did not significantly affect these flux levels, and no statistically significant interactions were found between house condition and location or house type. Many Broken Hill homes have high levels of lead flux that pose a potential risk to young children. Quantification of this hazard provides useful information for the community that can help focus efforts on actions required to minimise lead dust in the home. Household dust is a potential source of lead for young children in at-risk communities. Information on lead flux in homes can assist these communities and public health agencies to better understand and deal more effectively with the problem.

  11. Radon in indoor concentrations and indoor concentrations of metal dust particles in museums and other public buildings.

    Science.gov (United States)

    Carneiro, G L; Braz, D; de Jesus, E F; Santos, S M; Cardoso, K; Hecht, A A; Dias da Cunha, Moore K

    2013-06-01

    The aim of this study was to evaluate the public and occupational exposure to radon and metal-bearing particles in museums and public buildings located in the city of Rio de Janeiro, Brazil. For this study, four buildings were selected: two historic buildings, which currently house an art gallery and an art museum; and two modern buildings, a chapel and a club. Integrated radon concentration measurements were performed using passive radon detectors with solid state nuclear track detector-type Lexan used as nuclear track detector. Air samplers with a cyclone were used to collect the airborne particle samples that were analyzed by the particle-induced X-ray emission technique. The average unattached-radon concentrations in indoor air in the buildings were above 40 Bq/m(3), with the exception of Building D as measured in 2009. The average radon concentrations in indoor air in the four buildings in 2009 were below the recommended reference level by World Health Organization (100 Bq/m(3)); however, in 2011, the average concentrations of radon in Buildings A and C were above this level, though lower than 300 Bq/m(3). The average concentrations of unattached radon were lower than 148 Bq/m(3) (4pCi/L), the USEPA level recommended to take action to reduce the concentrations of radon in indoor air. The unattached-radon average concentrations were also lower than the value recommended by the European Union for new houses. As the unattached-radon concentrations were below the international level recommended to take action to reduce the radon concentration in air, it was concluded that during the period of sampling, there was low risk to human health due to the inhalation of unattached radon in these four buildings.

  12. Correlation between Yellow Dust and Radioactivity

    International Nuclear Information System (INIS)

    AIZaabia, Mouza A; Kim, Byoung-Jik

    2015-01-01

    In East Asia, yellow dust or Asian Dust (AD) outbreaks are among the largest contributors of wind-blown dust that carry natural and anthropogenic radionuclides and subsequently alter their concentration and distribution throughout the environment. Although the Korean Peninsula has been experiencing AD events since ancient times, the research has tended to focus on the transport routes and characteristics of AD, rather than on its impact on radionuclide activity levels. This paper examines the relationship between radionuclide concentration in the air and the frequency of dusty days in South Korea during AD intrusion events. It also investigates whether increased radionuclide concentration is a function of either more mass or more dust contamination. In this study, significant linear correlations of gamma-emitting radionuclides were found with mass of dust and occurrence frequency of AD. Regardless of the source origin of the dust, 137 Cs and 7 Be concentration primarily depended on dust mass in the filter. Nonetheless, the correlations were greatly distorted in 2011 and in the spring season, particularly the correlations with AD days that were far below that of the correlations obtained for the whole study period. A possible explanation of these conflicting results is that a change in the dust source could appreciably alter the concentration, deposition, and distribution of airborne radionuclides

  13. The concentration, source and deposition flux of ammonium and nitrate in atmospheric particles during dust events at a coastal site in northern China

    Science.gov (United States)

    Qi, Jianhua; Liu, Xiaohuan; Yao, Xiaohong; Zhang, Ruifeng; Chen, Xiaojing; Lin, Xuehui; Gao, Huiwang; Liu, Ruhai

    2018-01-01

    Asian dust has been reported to carry anthropogenic reactive nitrogen during transport from source areas to the oceans. In this study, we attempted to characterize NH4+ and NO3- in atmospheric particles collected at a coastal site in northern China during spring dust events from 2008 to 2011. Based on the mass concentrations of NH4+ and NO3- in each total suspended particle (TSP) sample, the samples can be classified into increasing or decreasing types. In Category 1, the concentrations of NH4+ and NO3- were 20-440 % higher in dust day samples relative to samples collected immediately before or after a dust event. These concentrations decreased by 10-75 % in the dust day samples in Categories 2 and 3. Back trajectory analysis suggested that multiple factors, such as the transport distance prior to the reception site, the mixing layer depth on the transport route and the residence time across highly polluted regions, might affect the concentrations of NH4+ and NO3-. NH4+ in the dust day samples was likely either in the form of ammonium salts existing separately to dust aerosols or as the residual of incomplete reactions between ammonium salts and carbonate salts. NO3- in the dust day samples was attributed to various formation processes during the long-range transport. The positive matrix factorization (PMF) receptor model results showed that the contribution of soil dust increased from 23 to 36 % on dust days, with decreasing contributions from local anthropogenic inputs and associated secondary aerosols. The estimated deposition flux of NNH4++NO3- varied greatly from event to event; e.g., the dry deposition flux of NNH4++NO3- increased by 9-285 % in Category 1 but decreased by 46-73 % in Category 2. In Category 3, the average dry deposition fluxes of particulate nitrate and ammonium decreased by 46 % and increased by 10 %, respectively, leading to 11-48 % decrease in the fluxes of NNH4++NO3-.

  14. Hierarchy and molecular properties of house dust mite allergens

    Directory of Open Access Journals (Sweden)

    Wayne R. Thomas

    2015-10-01

    Full Text Available The allergenic load of house dust mite allergy is largely constituted by a few proteins with a hierarchical pattern of allergenicity. The serodominant specificities are the group 1&2 and the group 23 faecal allergens. The collective IgE binding to the group 1&2 allergens can measure unequivocal HDM sensitisation better than HDM extracts although discrepancies have been found in regions with complex acarofauna suggesting a need to investigate the specificity with allergen components. The group 4, 5, 7&21 allergens that each induce responses in about 40% of subjects are mid-tier allergens accounting for most of the remaining IgE binding. Their titres are proportional to the concomitant responses to Der p1&2. Group 2 allergen variants have different antibody binding. Body proteins only occasionally induce sensitisation although a higher prevalence of binding by atopic dermatitis patients provides a new avenue of research. A broad spectrum of IgE binding has been associated with diverse symptoms but not with the severity of asthma which is associated with low IgG antibody. Some allergens such as the group 14 large lipid binding proteins and the recently described proteins Der f 24–33, need further investigation but with the cognoscence that other denominated allergens have been found to be minor sensitisers by comparative quantitative analyses. Scabies is a confounder for diagnosis with extracts, inducing cross-reactive antibodies with Der p 4&20 as is seafood allergy with cross reactivity to Der p 10 a minor HDM allergen. The HDM genome sequence can now be used to verify allelic and paralogous variations.

  15. CHARACTERIZATION OF THE DUST GENERATED IN THE RECYCLING PROCESS OF THE ELECTRIC ARC FURNACE DUST

    Directory of Open Access Journals (Sweden)

    Fábio Gonçalves Rizz

    2013-10-01

    Full Text Available Electric Arc Furnace Dust (EAFD is a solid waste generated by the production of steel through the Electric Arc Furnace. This waste is labeled dangerous, which motivates studies aiming its recycling. Experiments were made to study a pyrometallurgical process for the recycling of the dust, using the insertion of dust briquettes in molten pig iron in three temperatures. In the briquettes, there were made additions of calcium fluoride in four different concentrations. This paper has the objective to characterize the dust that results from this process, verifying the influence of the temperature and the concentration of calcium fluoride in the briquette in the morphology and chemical composition of the new dust, determining the optimal conditions for the recovery of the zinc content of the dust. This newly generated dust was analyzed in an Scanning Electronic Microscope, used to capture micrographs and chemical composition by EDS. The micrographs show that the temperature and the calcium fluoride concentration interfere in the way the dust particles agglomerate. Chemical analysis points that the higher zinc recuperation occurrs in the experiments at 1500°C with 7% addition of calcium fluoride.

  16. Human exposure to brominated flame retardants through dust in different indoor environments: Identifying the sources of concentration differences in hair from men and women.

    Science.gov (United States)

    Li, Junqi; Dong, Zheng; Wang, Ying; Bao, Junsong; Yan, Yijun; Liu, Anming; Jin, Jun

    2018-08-01

    Brominated flame retardants (BFRs) can accumulate in humans and are associated with adverse health effects. The study was conducted to determine the differences in Polybrominated diphenyl ethers (PBDEs) and alternative brominated flame retardant (Alt-BFR) concentrations between men and women. We analyzed hair samples from 14 male and 20 female university students, paired dust samples from their dormitories (10 for males and 8 for females), and six dust samples from university teaching buildings. The total PBDE concentrations in hair from females were significantly (three times) higher (p = 0.012) than that from males (means 372 and 109 ng/g, respectively). The mean total PBDE concentrations in classroom and dormitory dust were 36100 and 2012 ng/g, respectively. The PBDE patterns were different in the male and female hair samples, as were the patterns in the classroom and dormitory dust. There are no reports concerning human exposure to BFRs through dust that was assessed considering academic and residential environments simultaneously. The differences between BFR exposure for males and females and the differences between BFR concentrations in hair samples from males and females were consistent for 71.4% of the compounds. However, using only dormitory dust in the calculations gave consistent differences only for 28.6% of the compounds, suggesting that the BFR concentration differences in hair were mainly because females spent much more time than males in classrooms. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Correlation between Yellow Dust and Radioactivity

    Energy Technology Data Exchange (ETDEWEB)

    AIZaabia, Mouza A [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Kim, Byoung-Jik [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-10-15

    In East Asia, yellow dust or Asian Dust (AD) outbreaks are among the largest contributors of wind-blown dust that carry natural and anthropogenic radionuclides and subsequently alter their concentration and distribution throughout the environment. Although the Korean Peninsula has been experiencing AD events since ancient times, the research has tended to focus on the transport routes and characteristics of AD, rather than on its impact on radionuclide activity levels. This paper examines the relationship between radionuclide concentration in the air and the frequency of dusty days in South Korea during AD intrusion events. It also investigates whether increased radionuclide concentration is a function of either more mass or more dust contamination. In this study, significant linear correlations of gamma-emitting radionuclides were found with mass of dust and occurrence frequency of AD. Regardless of the source origin of the dust, {sup 137}Cs and {sup 7}Be concentration primarily depended on dust mass in the filter. Nonetheless, the correlations were greatly distorted in 2011 and in the spring season, particularly the correlations with AD days that were far below that of the correlations obtained for the whole study period. A possible explanation of these conflicting results is that a change in the dust source could appreciably alter the concentration, deposition, and distribution of airborne radionuclides.

  18. Paleo-dust insights onto dust-climate interactions

    Science.gov (United States)

    Albani, S.; Mahowald, N. M.

    2017-12-01

    Mineral dust emissions are affected by changing climate conditions, and in turn dust impacts the atmospheric radiation budget, clouds and biogeochemical cycles. Climate and public health dust-related issues call for attention on the fate of the dust cycle in the future, and the representation of the dust cycle is now part of the strategy of the Paleoclimate Modelling Intercomparison Project phase 4 and the Coupled Model Intercomparison Project phase 6 (PMIP4-CMIP6). Since mineral aerosols are one of the most important natural aerosols, understanding past dust responses to climate in the paleoclimate will allow us to better understand mineral aerosol feedbacks with climate and biogeochemistry in the Anthropocene. Modern observations and paleoclimate records offer the possibility of multiple, complementary views on the global dust cycle, and allow to validate and/or constrain the numerical representation of dust in climate and Earth system models. We present our results from a set of simulations with the Community Earth System Model for different climate states, including present and past climates such as the pre-industrial, the mid-Holocene and the Last Glacial Maximum. A set of simulations including a prognostic dust cycle was thoroughly compared with a wide set of present day observations from different platforms and regions, in order to realistically constrain the magnitude of dust load, surface concentration, deposition, optical properties, and particle size distributions. The magnitude of emissions for past climate regimes was constrained based on compilations of paleodust mass accumulation rates and size distributions, as well as based on information on dust provenance. The comparison with a parallel set of simulations without dust allows estimating the impacts of dust on surface climate. We analyze impacts of dust on the mean and variability of surface temperature and precipitation in each climate state, as well as the impacts that changing dust emissions had

  19. β Absorption dust concentration monitor system based on the PLC

    International Nuclear Information System (INIS)

    Lian Dexing; Zhou Xiuliang; Liu Liyan; Li Zonglun; Cao Guanghui; Mao Wanchong

    2011-01-01

    To provide an on-line automatic system for dust concentration monitor is the purpose of this design.The system based on β-ray-absorption-method,employing PLC (Programmable Logic Controller) control technology, is presented. The user input parameter setup,the data acquisition and processing, and the communication with computer can be effectively regulated using the advanced PLC control technology. It has the features of high reliability, easy operation and easy maintenance, and the ability to monitor remotely. Measurement range: 0.1-1500 mg/m 3 , Accuracy: ±9%. The structure,working principle, electric circuit and software development of the system are introduced in detail. (authors)

  20. Bee Venom Phospholipase A2 Ameliorates House Dust Mite Extract Induced Atopic Dermatitis Like Skin Lesions in Mice

    Directory of Open Access Journals (Sweden)

    Kyung-Hwa Jung

    2017-02-01

    Full Text Available Atopic dermatitis (AD is a biphasic inflammatory skin disease that is provoked by epidermal barrier defects, immune dysregulation, and increased skin infections. Previously, we have demonstrated that bvPLA2 evoked immune tolerance by inducing regulatory T cells (Treg, and thus alleviated Th2 dominant allergic asthma in mice. Here, we would like to determine whether treatment with bvPLA2 exacerbates the AD-like allergic inflammations induced by house dust mite extract (DFE in a murine model. Epidermal thickness, immune cell infiltration, serum immunoglobulin, and cytokines were measured. Ear swelling, skin lesions, and the levels of total serum IgE and Th1/Th2 cytokines were elevated in DFE/DNCB-induced AD mice. Topical application of bvPLA2 elicited significant suppression of the increased AD symptoms, including ear thickness, serum IgE concentration, inflammatory cytokines, and histological changes. Furthermore, bvPLA2 treatment inhibited mast cell infiltration into the ear. On the other hand, Treg cell depletion abolished the anti-atopic effects of bvPLA2, suggesting that the effects of bvPLA2 depend on the existence of Tregs. Taken together, the results revealed that topical exposure to bvPLA2 aggravated atopic skin inflammation, suggesting that bvPLA2 might be a candidate for the treatment of AD.

  1. Concentration Levels, Pollution Characteristics and Potential Ecological Risk of Dust Heavy Metals in the Metropolitan Area of Beijing, China.

    Science.gov (United States)

    Xiong, Qiulin; Zhao, Wenji; Zhao, Jiayin; Zhao, Wenhui; Jiang, Lei

    2017-09-30

    This study aims to investigate the concentration levels, pollution characteristics and the associated potential ecological risks of the heavy metals found in dust in the metropolitan area of Beijing, China during the winter. Dust samples were collected at 49 different spatial locations of Beijing's metropolitan area from November 2013 to January 2014, in which the concentration levels of Cd, Cr, Pb, Cu, Zn, Ni, Co, V, Bi and Mo were measured by Elan DRC II type inductively coupled plasma mass spectrometry (ICP-MS). Test results showed that the concentrations of dust heavy metals Pb, Cr, Cu and Zn in the urban areas (147.1 mg·kg -1 , 195.9 mg·kg -1 , 239.2 mg·kg -1 and 713.2 mg·kg -1 ) were significantly higher than those in the suburbs (91.6 mg·kg -1 , 125.1 mg·kg -1 , 131.9 mg·kg -1 and 514.5 mg·kg -1 ). Enrichment factors and the geo-accumulation index were used to describe the pollution characteristics of dust heavy metals in urban and suburban areas. Results indicated that Zn and Cu were moderately polluting in both urban and suburban areas, Cd was severely polluting in urban areas and heavily polluting in the suburbs. Furthermore, potential ecological risk assessment revealed that the degrees of ecological harm of dust heavy metals were very strong in both urban and suburban areas, but especially in urban areas. The potential ecological risk of heavy metal Cd, whose single factor of ecological damage was extremely strong, accounted for about 90% of the total ecological risk.

  2. House Dust Mite Allergen Regulates Constitutive Apoptosis of Normal and Asthmatic Neutrophils via Toll-Like Receptor 4.

    Directory of Open Access Journals (Sweden)

    Do Hyung Kim

    Full Text Available House dust mites (HDMs induce allergic diseases such as asthma. Neutrophil apoptosis is an important process of innate immunity, and its dysregulation is associated with asthma. In this study, we examined the effects of HDM on constitutive apoptosis of normal and asthmatic neutrophils. Extract of Dermatophagoides pteronissinus (DP inhibited neutrophil apoptosis, but Dermatophagoides farinae extract had no effect. Anti-apoptotic signaling mediated by DP involves in TLR4, Lyn, PI3K, Akt, ERK, and NF-κB in normal neutrophils. DP delayed cleavage of procaspase 9 and procaspase 3 and the decrease in Mcl-1 expression. Supernatant collected from DP-treated normal neutrophils inhibited the constitutive apoptosis of normal neutrophils, and S100A8 and S100A9 were identified as anti-apoptotic proteins in the supernatant. S100A8 and S100A9 transduced the anti-apoptotic signal via TLR4, Lyn, PI3K, Akt, ERK, and NF-κB. DP also suppressed asthmatic neutrophil apoptosis and induced secretion of S100A8 and S100A9, which delayed the constitutive apoptosis. The anti-apoptotic effects of DP, S100A8 and S100A9 in asthmatic neutrophils are associated with TLR4, Lyn, PI3K, Akt, ERK, and NF-κB. The concentrations of S100A8 and S100A9 were significantly elevated in asthmatic bronchoalveolar lavage fluid (BALF when compared to normal BALF (p<0.01, but not in serum. S100A8 concentration in BALF was positively correlated with the number of BALF neutrophils and negatively correlated with FEV1(%. These findings improve our understanding of the role of HDM in regulation of neutrophil apoptosis in normal individuals and asthmatics and will enable elucidation of asthma pathogenesis.

  3. Nocturnal thoracoabdominal asynchrony in house dust mite-sensitive nonhuman primates

    Directory of Open Access Journals (Sweden)

    XiaoJia Wang

    2010-07-01

    Full Text Available XiaoJia Wang, Shaun Reece, Stephen Olmstead, Robert L Wardle, Michael R Van ScottDepartment of Physiology, East Carolina University, Greenville, North Carolina, USAAbstract: Nocturnal bronchoconstriction is a common symptom of asthma in humans, but is poorly documented in animal models. Thoracoabdominal asynchrony (TAA is a noninvasive clinical indication of airway obstruction. In this study, respiratory inductive plethysmography (RIP was used to document nocturnal TAA in house dust mite (HDM-sensitive Cynomolgus macaques. Dynamic compliance (Cdyn and lung resistance (RL measured in anesthetized ­animals at rest and following exposure to HDM allergen, methacholine, and albuterol were highly ­correlated with three RIP parameters associated with TAA, ie, phase angle of the rib cage and abdomen waveforms (PhAng, baseline effort phase relation (eBPRL and effort phase relation (ePhRL. Twenty-one allergic subjects were challenged with HDM early in the morning, and eBPRL and ePhRL were monitored for 20 hours after provocation. Fifteen of the allergic subjects exhibited gradual increases in eBPRL and ePhRL between midnight and 6 am, with peak activity at 4 am. However, as in humans, this nocturnal response was highly variable both between subjects and within subjects over time. The results document that TAA in this nonhuman primate model of asthma is highly correlated with Cdyn and RL, and demonstrate that animals exhibiting acute responses to allergen exposure during the day also exhibit nocturnal TAA.Keywords: nocturnal asthma, late phase asthmatic response, respiratory inductive plethysmography

  4. Allergic asthma induced in rhesus monkeys by house dust mite (Dermatophagoides farinae).

    Science.gov (United States)

    Schelegle, E S; Gershwin, L J; Miller, L A; Fanucchi, M V; Van Winkle, L S; Gerriets, J P; Walby, W F; Omlor, A M; Buckpitt, A R; Tarkington, B K; Wong, V J; Joad, J P; Pinkerton, K B; Wu, R; Evans, M J; Hyde, D M; Plopper, C G

    2001-01-01

    To establish whether allergic asthma could be induced experimentally in a nonhuman primate using a common human allergen, three female rhesus monkeys (Macaca mulatta) were sensitized with house dust mite (Dermatophagoides farinae) allergen (HDMA) by subcutaneous injection, followed by four intranasal sensitizations, and exposure to allergen aerosol 3 hours per day, 3 days per week for up to 13 weeks. Before aerosol challenge, all three monkeys skin-tested positive for HDMA. During aerosol challenge with HDMA, sensitized monkeys exhibited cough and rapid shallow breathing and increased airway resistance, which was reversed by albuterol aerosol treatment. Compared to nonsensitized monkeys, there was a fourfold reduction in the dose of histamine aerosol necessary to produce a 150% increase in airway resistance in sensitized monkeys. After aerosol challenge, serum levels of histamine were elevated in sensitized monkeys. Sensitized monkeys exhibited increased levels of HDMA-specific IgE in serum, numbers of eosinophils and exfoliated cells within lavage, and elevated CD25 expression on circulating CD4(+) lymphocytes. Intrapulmonary bronchi of sensitized monkeys had focal mucus cell hyperplasia, interstitial infiltrates of eosinophils, and thickening of the basement membrane zone. We conclude that a model of allergic asthma can be induced in rhesus monkeys using a protocol consisting of subcutaneous injection, intranasal instillation, and aerosol challenge with HDMA.

  5. HLA class II association with Type I allergy to house dust mite and Japanese cedar pollen in Japanese subjects

    Directory of Open Access Journals (Sweden)

    Yasuaki Sadanaga

    1998-01-01

    Full Text Available We evaluated the incidence of the association of HLA class II phenotype and specific IgE responsiveness against house dust mite (HDM and/or Japanese cedar pollen (Jc in 176 patients with allergic rhinitis, with or without bronchial asthma, and 107 nonallergic subjects. Specific IgE antibody titration against the purified allergens Der f1 and Der f2 from HDM, and against Cry J1 and Cry J2 from Jc, was performed by using enzyme-linked immunosorbent assay (ELISA and radioimmunoassay (RIA in sera from all subjects. HLA class II oligotyping was performed by the polymerase chain reaction sequence specific oligonucleotide (PCR-SSO method on the DRB1*, DQA1*, DQB1* and DPB1* alleles using peripheral blood cells. The high IgE responders ≥ class 4 to the purified allergens were identified by using the IgE antibody reference concentration obtained by ELISA, RIA and routine IgE CAP RAST. Compared to the controls, the patients with both rhinitis and asthma showed significantly higher frequencies of DRB1* 0901, DQB1* 0303, and DPB1* 0401 alleles. High IgE responsiveness to HDM was associated with DRB1* 1101, 0901, DQB1* 0303, and DPB1*0401 alleles. The patients with anti-Der f1 IgE antibody concentration exceeding 72.2 ng/mL showed significantly elevated frequencies for DQB1*0401 and DPB1*0401 alleles, and those with anti Der f2 IgE antibody concentration exceeding 46.2 ng/mL showed significantly elevated frequencies for DPB1*0401 and 0901 alleles. High IgE responsiveness to Jc with Cry j1 and Cryj2was associated with the DRB1* 1201 alleles.

  6. Radon concentration studies in houses on the territory of the former German Democratic Republic

    International Nuclear Information System (INIS)

    Lehmann, R.

    1993-01-01

    In cooperation with the Federal Institute of Water, Soil and Air Hygiene, studies have been made since March 1990 in mining centers in the South of the former GDR territory on radon concentration in as many differently used houses as possible, predominantly in dwelling houses, but also in plant buildings, schools, kindergartens, recreation homes, etc. Under this program, measurements were performed until October 1990 in the cities of Schneeberg, Johanngeorgenstadt and Ronneburg and in the municipality of Schlema. The results obtained from this radon screening covering almost the whole affected area, qualitatively correspond to those obtained from small random samples taken under a regional measuring program performed in the respective muncipalities. A summary presentation is given of the range of radon concentration in houses to be expected in East Germany, relating it to geologically different areas in accordance with the present state of knowledge. (orig./DG) [de

  7. The Relationship between Aerosol Composition and Concentration and Visual Range on Barbados, West Indies: The Impact of African Dust

    Science.gov (United States)

    Huang, J.; Prospero, J.; Zhang, C.; Arimoto, R.

    2006-12-01

    Visual Range (VR) measured at Grantley Adams Airport on Barbados shows a very strong annual cycle with the minimum VR values occurring in June or July. This cycle closely matches the annual cycle of African dust concentrations measured in the trade winds at Barbados (13°15'N, 59°30'W) where observations first began in 1965. In winter, monthly mean VR was typically around 30 km or greater while in summer it frequently dipped below 20 km. This same clear signal is observed in the VR records from near-by islands where the same seasonal cycle of dust would be expected: St. Lucia, Martinique and Trinidad and Tobago. We examined the relationship between VR on Barbados and the concentrations of the three major aerosol constituents that we would expect to have the strongest influence on VR: mineral dust, sea salt, and non-sea- salt sulfate (nss-SO4^{=}). We used VR data for the period from 1973, when measurements first began, up to 2006. We found a large discrepancy between the observed VR at the airport and the VR derived from the Koschmieder equation using literature values for the optical properties of the aerosol components; this simple approach would require a much smaller constant than the commonly-used value, 3.912. We further explored the effects of particle size distribution and relative humidity. During boreal summer when VR is lowest, dust is the dominant supramicron aerosol component and it clearly is the major factor in controlling VR. Nonetheless the submicron fraction also has a comparable impact due to its significantly higher light scattering efficiency. During winter, when there is little or no dust, sea salt aerosol and sulfate are dominant. In this report we focus on the various factors that affect visibility on Barbados especially the role of aerosols dominated by supramicrometer particles. We also consider the effects of other factors such as wind speed and precipitation. Finally, we note that the close relationship between summertime VR and dust

  8. Laboratory study of PCB transport from primary sources to settled dust

    Science.gov (United States)

    Transport of house dust and Arizona Test Dust on polychlorinated biphenyl (PCB)-containing panels and PCB-free panels was investigated in a 30-m3 stainless steel chamber. The PCB-containing panels were aluminum sheets coated with a PCB-spiked, oil-based primer or two-part polysul...

  9. Maatregelen ter vermindering van fijnstofemissie uit de pluimveehouderij; studie naar mogelijkheden van aanbrengen waterfilm op strooisel = Measures to reduce fine dust emissions from poultry houses; possibility of supplying a waterfilm on litter

    NARCIS (Netherlands)

    Ellen, H.H.; Harn, van J.

    2010-01-01

    In this desk study the possibilities of reducing fine dust emission from poultry housings by applying a water film on bedding material was studied. This measure can be perspective in laying hens, but not in broilers and parent stock.

  10. A case of extreme particulate matter concentrations over Central Europe caused by dust emitted over the southern Ukraine

    Directory of Open Access Journals (Sweden)

    W. Birmili

    2008-02-01

    Full Text Available On 24 March 2007, an extraordinary dust plume was observed in the Central European troposphere. Satellite observations revealed its origins in a dust storm in Southern Ukraine, where large amounts of soil were resuspended from dried-out farmlands at wind gusts up to 30 m s−1. Along the pathway of the plume, maximum particulate matter (PM10 mass concentrations between 200 and 1400 μg m−3 occurred in Slovakia, the Czech Republic, Poland, and Germany. Over Germany, the dust plume was characterised by a volume extinction coefficient up to 400 Mm−1 and a particle optical depth of 0.71 at wavelength 0.532 μm. In-situ size distribution measurements as well as the wavelength dependence of light extinction from lidar and Sun photometer measurements confirmed the presence of a coarse particle mode with diameters around 2–3 μm. Chemical particle analyses suggested a fraction of 75% crustal material in daily average PM10 and up to 85% in the coarser fraction PM10–2.5. Based on the particle characteristics as well as a lack of increased CO and CO2 levels, a significant impact of biomass burning was ruled out. The reasons for the high particle concentrations in the dust plume were twofold: First, dust was transported very rapidly into Central Europe in a boundary layer jet under dry conditions. Second, the dust plume was confined to a relatively stable boundary layer of 1.4–1.8 km height, and could therefore neither expand nor dilute efficiently. Our findings illustrate the capacity of combined in situ and remote sensing measurements to characterise large-scale dust plumes with a variety of aerosol parameters. Although such plumes from Southern Eurasia seem to occur rather infrequently in Central Europe, its unexpected features highlights the need to improve the description of dust emission, transport and transformation processes needs, particularly when facing the

  11. The Continuous Monitoring of Desert Dust using an Infrared-based Dust Detection and Retrieval Method

    Science.gov (United States)

    Duda, David P.; Minnis, Patrick; Trepte, Qing; Sun-Mack, Sunny

    2006-01-01

    Airborne dust and sand are significant aerosol sources that can impact the atmospheric and surface radiation budgets. Because airborne dust affects visibility and air quality, it is desirable to monitor the location and concentrations of this aerosol for transportation and public health. Although aerosol retrievals have been derived for many years using visible and near-infrared reflectance measurements from satellites, the detection and quantification of dust from these channels is problematic over bright surfaces, or when dust concentrations are large. In addition, aerosol retrievals from polar orbiting satellites lack the ability to monitor the progression and sources of dust storms. As a complement to current aerosol dust retrieval algorithms, multi-spectral thermal infrared (8-12 micron) data from the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Meteosat-8 Spinning Enhanced Visible and Infrared Imager (SEVIRI) are used in the development of a prototype dust detection method and dust property retrieval that can monitor the progress of Saharan dust fields continuously, both night and day. The dust detection method is incorporated into the processing of CERES (Clouds and the Earth s Radiant Energy System) aerosol retrievals to produce dust property retrievals. Both MODIS (from Terra and Aqua) and SEVERI data are used to develop the method.

  12. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings.

    Science.gov (United States)

    Beamer, P I; Sugeng, A J; Kelly, M D; Lothrop, N; Klimecki, W; Wilkinson, S T; Loh, M

    2014-05-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites.

  13. Protocol Implementation for Radon Concentration Measurements in Houses in Croatia - Baranja Case

    International Nuclear Information System (INIS)

    Radolic, V.; Miklavcic, I.; Poje, M.; Stanic, D.; Varga Pajtler, M.; Vukovic, B.

    2011-01-01

    The newly established protocol for radon measurements in homes was implemented on the radon survey in houses of Baranja region which was carried out from July 2009 until July 2010. The radon measurements were performed with passive track etched detectors. The method consists of cylindrical plastic vessel and two strippable LR-115 films type II (Kodak-Path, France). This method with two detector films enables the estimation of equilibrium factor as well.Croatian territory is divided in 10 x 10 km 2 cells which were part of a reference grid map which is used in a preparation of European radon concentration map. Detector locations were randomly chosen inside each grid and their number was determined by the number of inhabitants inside (one locations per 350 inhabitants). Radon detectors were exposed for a year in a living room or a bedroom away from strong ventilation and 30 cm from side walls (usually on closet at height of 2 m). After the exposure, detectors were collected and etched in 10 % NaOH aqueous solution at 50 degrees of C for 180 minutes. The tracks were automatically counted using spark counter AIST-2V. The obtained results were in the range from 6 to 355 Bq m -3 with arithmetic mean of 88 Bq m -3 and standard deviation of 69.0 Bq m -3 . The geometric mean was 67.2 Bq m -3 while the geometric standard deviation was 2.1 Bq m -3 . The statistical χ2 -test showed that the empirical frequency distribution for radon in houses of Baranja region belonged to the log-normal distribution. The percentage of houses with radon concentrations between 200 and 400 Bq m -3 was 6.7% and 1.0% of houses have radon concentration above 400 Bq m -3 . The annual effective dose from the indoor radon and its short-lived progenies for the inhabitants of Baranja region (for the average equilibrium factor of 0.53 and occupancy factor of 0.6) was 1.5 mSv. (author)

  14. Polybrominated diphenyl ethers and alternative flame retardants in house dust in Denmark – levels, patterns and changes over time

    DEFF Research Database (Denmark)

    Vorkamp, Katrin; Frederiksen, Marie; Nielsen, Jesper Bo

    2016-01-01

    -DBPE) and dechlorane plus (DDC-CO). Furthermore, hexabromocyclododecane (HBCD) was included although globally banned since 2013. While TBP-DBPE was below detection limits in several dust samples, the remaining NFRs were detected in all samples from 2007 and 2014. DDC-CO had relatively low concentrations (median

  15. Dust-Tolerant Intelligent Electrical Connection System

    Science.gov (United States)

    Lewis, Mark; Dokos, Adam; Perotti, Jose; Calle, Carlos; Mueller, Robert; Bastin, Gary; Carlson, Jeffrey; Townsend, Ivan, III; Immer, Chirstopher; Medelius, Pedro

    2012-01-01

    Faults in wiring systems are a serious concern for the aerospace and aeronautic (commercial, military, and civilian) industries. Circuit failures and vehicle accidents have occurred and have been attributed to faulty wiring created by open and/or short circuits. Often, such circuit failures occur due to vibration during vehicle launch or operation. Therefore, developing non-intrusive fault-tolerant techniques is necessary to detect circuit faults and automatically route signals through alternate recovery paths while the vehicle or lunar surface systems equipment is in operation. Electrical connector concepts combining dust mitigation strategies and cable diagnostic technologies have significant application for lunar and Martian surface systems, as well as for dusty terrestrial applications. The dust-tolerant intelligent electrical connection system has several novel concepts and unique features. It combines intelligent cable diagnostics (health monitoring) and automatic circuit routing capabilities into a dust-tolerant electrical umbilical. It retrofits a clamshell protective dust cover to an existing connector for reduced gravity operation, and features a universal connector housing with three styles of dust protection: inverted cap, rotating cap, and clamshell. It uses a self-healing membrane as a dust barrier for electrical connectors where required, while also combining lotus leaf technology for applications where a dust-resistant coating providing low surface tension is needed to mitigate Van der Waals forces, thereby disallowing dust particle adhesion to connector surfaces. It also permits using a ruggedized iris mechanism with an embedded electrodynamic dust shield as a dust barrier for electrical connectors where required.

  16. Association of Children’s Urinary CC16 Levels with Arsenic Concentrations in Multiple Environmental Media

    Directory of Open Access Journals (Sweden)

    Paloma I. Beamer

    2016-05-01

    Full Text Available Arsenic exposure has been associated with decreased club cell secretory protein (CC16 levels in adults. Further, both arsenic exposure and decreased levels of CC16 in childhood have been associated with decreased adult lung function. Our objective was to determine if urinary CC16 levels in children are associated with arsenic concentrations in environmental media collected from their homes. Yard soil, house dust, and tap water were taken from 34 homes. Urine and toenail samples were collected from 68 children. All concentrations were natural log-transformed prior to data analysis. There were associations between urinary CC16 and arsenic concentration in soil (b = −0.43, p = 0.001, R2 = 0.08, water (b = −0.22, p = 0.07, R2 = 0.03, house dust (b = −0.37, p = 0.07, R2 = 0.04, and dust loading (b = −0.21, p = 0.04, R2 = 0.04. In multiple analyses, only the concentration of arsenic in soil was associated with urinary CC16 levels (b = −0.42, p = 0.02, R2 = 0.14 (full model after accounting for other factors. The association between urinary CC16 and soil arsenic may suggest that localized arsenic exposure in the lungs could damage the airway epithelium and predispose children for diminished lung function. Future work to assess this possible mechanism should examine potential associations between airborne arsenic exposures, CC16 levels, lung function, and other possible confounders in children in arsenic-impacted communities.

  17. Normal and anomalous diffusion in fluctuations of dust concentration nearby emission source

    Science.gov (United States)

    Szczurek, Andrzej; Maciejewska, Monika; Wyłomańska, Agnieszka; Sikora, Grzegorz; Balcerek, Michał; Teuerle, Marek

    2018-02-01

    Particulate matter (PM) is an important component of air. Nowadays, major attention is payed to fine dust. It has considerable environmental impact, including adverse effect on human health. One of important issues regarding PM is the temporal variation of its concentration. The variation contains information about factors influencing this quantity in time. The work focuses on the character of PM concentration dynamics indoors, in the vicinity of emission source. The objective was to recognize between the homogeneous or heterogeneous dynamics. The goal was achieved by detecting normal and anomalous diffusion in fluctuations of PM concentration. For this purpose we used anomalous diffusion exponent, β which was derived from Mean Square Displacement (MSD) analysis. The information about PM concentration dynamics may be used to design sampling strategy, which serves to attain representative information about PM behavior in time. The data analyzed in this work was collected from single-point PM concentration monitoring in the vicinity of seven emission sources in industrial environment. In majority of cases we observed heterogeneous character of PM concentration dynamics. It confirms the complexity of interactions between the emission sources and indoor environment. This result also votes against simplistic approach to PM concentration measurement indoors, namely their occasional character, short measurement periods and long term averaging.

  18. House Dust Mite Der p 1 Effects on Sinonasal Epithelial Tight Junctions

    Science.gov (United States)

    Henriquez, Oswaldo A.; Beste, Kyle Den; Hoddeson, Elizabeth K.; Parkos, Charles A.; Nusrat, Asma; Wise, Sarah K.

    2013-01-01

    Background Epithelial permeability is highly dependent upon the integrity of tight junctions, cell-cell adhesion complexes located at the apical aspect of the lateral membrane of polarized epithelial cells. We hypothesize that sinonasal epithelial exposure to Der p 1 house dust mite antigen decreases expression of tight junction proteins (TJPs), representing a potential mechanism for increased permeability and presentation of antigens across the sinonasal epithelial layer. Methods Confluent cultured primary human sinonasal epithelial cells were exposed to recombinant Der p 1 antigen versus control, and transepithelial resistance measurements were performed over 24 hours. Antibody staining for a panel of tight junction proteins was examined with immunofluorescence/confocal microscopy and Western blotting. Tissue for these experiments was obtained from 4 patients total. Results Der p 1 exposed sinonasal cells showed a marked decrease in transepithelial resistance when compared to control cells. In addition, results of Western immunoblot and immunofluorescent labeling demonstrated decreased expression of TJPs claudin-1 and junction adhesion molecule-A (JAM-A) in Der p 1 exposed cultured sinonasal cells versus controls. Conclusion Der p 1 antigen exposure decreases sinonasal epithelium TJP expression, most notably seen in JAM-A and claudin-1 in these preliminary experiments. This decreased TJP expression likely contributes to increased epithelial permeability and represents a potential mechanism for transepithelial antigen exposure in allergic rhinitis. PMID:23592402

  19. Personal exposure to inhalable cement dust among construction workers.

    Science.gov (United States)

    Peters, Susan; Thomassen, Yngvar; Fechter-Rink, Edeltraud; Kromhout, Hans

    2009-01-01

    Objective- A case study was carried out to assess cement dust exposure and its determinants among construction workers and for comparison among workers in cement and concrete production.Methods- Full-shift personal exposure measurements were performed and samples were analysed for inhalable dust and its cement content. Exposure variability was modelled with linear mixed models.Results- Inhalable dust concentrations at the construction site ranged from 0.05 to 34 mg/m(3), with a mean of 1.0 mg/m(3). Average concentration for inhalable cement dust was 0.3 mg/m(3) (GM; range 0.02-17 mg/m(3)). Levels in the ready-mix and pre-cast concrete plants were on average 0.5 mg/m(3) (GM) for inhalable dust and 0.2 mg/m(3) (GM) for inhalable cement dust. Highest concentrations were measured in cement production, particularly during cleaning tasks (inhalable dust GM = 55 mg/m(3); inhalable cement dust GM = 33 mg/m(3)) at which point the workers wore personal protective equipment. Elemental measurements showed highest but very variable cement percentages in the cement plant and very low percentages during reinforcement work and pouring. Most likely other sources were contributing to dust concentrations, particularly at the construction site. Within job groups, temporal variability in exposure concentrations generally outweighed differences in average concentrations between workers. 'Using a broom', 'outdoor wind speed' and 'presence of rain' were overall the most influential factors affecting inhalable (cement) dust exposure.Conclusion- Job type appeared to be the main predictor of exposure to inhalable (cement) dust at the construction site. Inhalable dust concentrations in cement production plants, especially during cleaning tasks, are usually considerably higher than at the construction site.

  20. Grain dust and the lungs.

    Science.gov (United States)

    Chan-Yeung, M.; Ashley, M. J.; Grzybowski, S.

    1978-01-01

    Grain dust is composed of a large number of materials, including various types of grain and their disintegration products, silica, fungi, insects and mites. The clinical syndromes described in relation to exposure to grain dust are chronic bronchitis, grain dust asthma, extrinsic allergic alveolitis, grain fever and silo-filler's lung. Rhinitis and conjunctivitis are also common in grain workers. While the concentration and the quality of dust influence the frequency and the type of clinical syndrome in grain workers, host factors are also important. Of the latter, smoking is the most important factor influencing the frequency of chronic bronchitis. The role of atopy and of bronchial hyperreactivity in grain dust asthma has yet to be assessed. Several well designed studies are currently being carried out in North America not only to delineate the frequency of the respiratory abnormalities, the pathogenetic mechanisms and the host factors, but also to establish a meaningful threshold limit concentration for grain dust. Images p1272-a PMID:348288

  1. Further Analysis on the Mystery of the Surveyor III Dust Deposits

    Science.gov (United States)

    Metzger, Philip; Hintze, Paul; Trigwell, Steven; Lane, John

    2012-01-01

    The Apollo 12 lunar module (LM) landing near the Surveyor III spacecraft at the end of 1969 has remained the primary experimental verification of the predicted physics of plume ejecta effects from a rocket engine interacting with the surface of the moon. This was made possible by the return of the Surveyor III camera housing by the Apollo 12 astronauts, allowing detailed analysis of the composition of dust deposited by the LM plume. It was soon realized after the initial analysis of the camera housing that the LM plume tended to remove more dust than it had deposited. In the present study, coupons from the camera housing have been reexamined. In addition, plume effects recorded in landing videos from each Apollo mission have been studied for possible clues.

  2. Analysis of the Difference of Radon Concentration between Water Treatment Plant and Tap water in house

    International Nuclear Information System (INIS)

    Seo, Jeongil; Yoo, Donghan; Kim, Heereyoung

    2013-01-01

    As importance for the health, measurements and analysis about radon is active recently. Especially, radon concentration measurement about underground water which people drink was been carried out by the environment organizations in Korea and has been hot-issued because of the high radon concentration in water source. In present study, the difference of radon concentration among water source, water treatment plant and tap water in house is analyzed. It makes sense that the radon concentration in water treatment plant can represent the radon concentration in the tap water. Through the above experiments, the difference of the radon concentration between water treatment plant and tap water in house is figured out. It contributes to confirm more specific basis for estimating the annual radon exposure for the public. With further experiments and analysis, it is thought that it will be used as tool to assess more qualitatively for the radon concentration in tap water. Finally, this Fundamental approach will help in making new regulations about radon

  3. Analysis of the Difference of Radon Concentration between Water Treatment Plant and Tap water in house

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeongil; Yoo, Donghan; Kim, Heereyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2013-05-15

    As importance for the health, measurements and analysis about radon is active recently. Especially, radon concentration measurement about underground water which people drink was been carried out by the environment organizations in Korea and has been hot-issued because of the high radon concentration in water source. In present study, the difference of radon concentration among water source, water treatment plant and tap water in house is analyzed. It makes sense that the radon concentration in water treatment plant can represent the radon concentration in the tap water. Through the above experiments, the difference of the radon concentration between water treatment plant and tap water in house is figured out. It contributes to confirm more specific basis for estimating the annual radon exposure for the public. With further experiments and analysis, it is thought that it will be used as tool to assess more qualitatively for the radon concentration in tap water. Finally, this Fundamental approach will help in making new regulations about radon.

  4. Personal exposure to inhalable cement dust among construction workers

    International Nuclear Information System (INIS)

    Peters, Susan; Kromhout, Hans; Thomassen, Yngvar; Fechter-Rink, Edeltraud

    2009-01-01

    A case study was carried out in 2006-2007 to assess the actual cement dust exposure among construction workers involved in a full-scale construction project and as a comparison among workers involved in various stages of cement and concrete production. Full-shift personal exposure measurements were performed for several job types. Inhalable dust and cement dust (based on analysis of elemental calcium) concentrations were determined. Inhalable dust exposures at the construction site ranged from 0.05 to 34 mg/m3, with a mean concentration of 1.0 mg/m3. For inhalable cement dust mean exposure was 0.3 mg/m3 (range 0.02-17 mg/m3). Reinforcement and pouring workers had the lowest average concentrations. Inhalable dust levels in the ready-mix and pre-cast concrete plants were, on average, below 0.5 mg/m3 for inhalable dust and below 0.2 mg/m3 for inhalable cement dust. Highest dust concentrations were measured in cement production, particularly during cleaning tasks (inhalable dust GM=55 mg/m3; inhalable cement dust GM=33 mg/m3) at which point the workers wore personal protective equipment. Elemental measurements showed highest but very variable cement percentages in the cement plant and very low percentages of cement during reinforcement work and pouring.

  5. Temporal Trends in Airborne Dust Concentrations at a Large Chrysotile Mine and its Asbestos-enrichment Factories in the Russian Federation During 1951-2001

    NARCIS (Netherlands)

    Schonfeld, Sara J; Kovalevskiy, Evgeny V; Feletto, Eleonora; Bukhtiyarov, Igor V; Kashanskiy, Sergey V; Moissonier, Monika; Straif, Kurt; McCormack, Valerie A; Schüz, Joachim; Kromhout, Hans

    2017-01-01

    Objectives: Mining and processing of chrysotile, an established carcinogen, has been undertaken in Asbest, Russian Federation since the late 1800s. Dust concentrations were routinely recorded at the open-pit mine and its asbestos-enrichment factories. We examined the temporal trends in these dust

  6. Concentration levels of radon in air, indoors and outdoors in houses of Mexico City

    International Nuclear Information System (INIS)

    Pena Garcia, P.

    1992-01-01

    Concentration levels of radon in air, indoors and outdoors have been obtained in houses from Mexico City, with the purpose of relating them with the local environment. Measurements were performed both outdoors and indoors in 60 unifamiliar houses. Track detectors, LR-115, Type II, were used in several detection arrangements during four recording periods with times of exposure of three months each, with the purpose of analyzing the fluctuations due to seasonal changes. Data were obtained about the construction materials were the detection systems were located in order to establish a correlation of radon levels with the climatic parameters and the construction materials. The results of radon concentrations both indoors or outdoors were lower than the international recommendations (148 Bq/m 3 ) (Author)

  7. The impact of housing policies and housing markets on ethnic spatial segregation

    DEFF Research Database (Denmark)

    Andersen, Hans Skifter; Andersson, Roger; Wessel, Terje

    2015-01-01

    This paper examines how ethnic segregation is connected to an ethnic division of the housing market and a spatial separation of different housing tenures in four Nordic cities. Explanations for the differences across the cities are found by comparing housing markets and housing policies....... The housing markets are in all four cities ethnically segmented with high concentrations of immigrants in some forms of tenures (especially social/public housing) and low concentrations in others. We further discuss the reasons for the observed pattern. The paper shows that the spatial distribution...... housing, while co-operative housing is crucial in the fourth. It is also shown that a policy of neighbourhood tenure mix in one of the cities has resulted in a relatively low degree of segregation in spite of high concentrations of immigrants in social/public housing....

  8. House dust extracts have both TH2 adjuvant and tolerogenic activities.

    Science.gov (United States)

    Ng, Nicholas; Lam, Diane; Paulus, Petra; Batzer, Glenda; Horner, Anthony A

    2006-05-01

    Although mechanisms remain a subject of controversy, there is general agreement that living environments influence allergic risk during the first years of life. We reasoned that sterile house dust extracts (HDEs) would have immunologic activities reflective of their environments of origin and therefore would be useful surrogates for investigations of how ambient exposures influence immune homeostasis. These experiments determined how airway HDE exposures influence adaptive responses to a coadministered antigen and subsequent airway hypersensitivity responses to antigen challenge. Mice received intranasal ovalbumin (OVA) vaccinations on a weekly basis. Select groups of mice also received intranasal HDE weekly with OVA; daily at one seventh the weekly dose, beginning 7 days before the first OVA sensitization; or both. Weekly intranasal vaccinations with OVA and HDE primed mice for the development of T(H)2-biased immune and airway hypersensitivity responses. In contrast, daily low-dose intranasal HDE exposures protected against the immunologic and pathologic outcomes associated with weekly intranasal OVA/HDE vaccinations. The T(H)2 adjuvant activities of HDEs were found to be dependant on MyD88, a molecule critical for signaling through a majority of Toll-like receptors. Moreover, the tolerogenic activity associated with daily intranasal HDE exposures could be replicated with LPS. These investigations demonstrate that in addition to allergens, living environments contain immunomodulatory materials with both T(H)2 adjuvant and tolerogenic activities. As the contents of HDEs are ubiquitous, these experiments might recapitulate and help explain clinically relevant immunologic events involved in the maintenance of aeroallergen tolerance and the dysregulated responses that lead to allergic respiratory diseases.

  9. Polybrominated diphenyl ethers in paired samples of maternal and umbilical cord blood plasma and associations with house dust in a Danish cohort

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Thomsen, Cathrine; Frøshaug, May

    2010-01-01

    determined in placental tissue from the same individuals, and the relationship with the external exposure from house dust from the participants' homes was explored. Samples of maternal and umbilical cord plasma from a cohort of 51 pregnant women from the Copenhagen area were collected. Paired maternal...... and umbilical cord plasma were analysed for BDE-28, 37, 47, 85, 99, 100, 119, 138, 153, 154, 183, 209 and the brominated biphenyl BB-153 using automated SPE extraction and GC-HRMS for the tri- to hepta-BDEs and GC-LRMS (ECNI) for BDE-209. PBDEs were detected in all maternal and umbilical cord plasma samples...

  10. [Sampling of allergens in dust deposited in the workplace].

    Science.gov (United States)

    Perfetti, L; Galdi, E; Pozzi, V; Moscato, G

    2001-01-01

    Some workplaces share with domestic dwellings many characteristics favouring house dust mite growth. Moreover it has recently been shown that pets owners can bring allergens to public places with their clothes. So it is possible that significant exposure to indoor allergens can occur outside homes, at the workplace. The recent availability of immunoassays with monoclonal antibodies for indoor allergens has enabled many investigators to quantify exposure to such allergens in epidemiological studies. Analysis of allergens in settled dust is a simple method of quantification exposure to indoor allergens. The concentrations of indoor allergens in public places have already been investigated and high levels of indoor allergens have been reported. A study performed by our group in offices (banks and media) in different regions of Italy has also shown significant levels of indoor allergens. Thus, evaluating exposure to indoor allergens at the workplace is critical to evaluate risk factors for sensitization and elicitation of symptoms in sensitized subjects and such data help in addressing correctly the problem of reducing exposure levels.

  11. PM10 concentration levels at an urban and background site in Cyprus: the impact of urban sources and dust storms.

    Science.gov (United States)

    Achilleos, Souzana; Evans, John S; Yiallouros, Panayiotis K; Kleanthous, Savvas; Schwartz, Joel; Koutrakis, Petros

    2014-12-01

    Air quality in Cyprus is influenced by both local and transported pollution, including desert dust storms. We examined PM10 concentration data collected in Nicosia (urban representative) from April 1, 1993, through December 11, 2008, and in Ayia Marina (rural background representative) from January 1, 1999, through December 31, 2008. Measurements were conducted using a Tapered Element Oscillating Micro-balance (TEOM). PM10 concentrations, meteorological records, and satellite data were used to identify dust storm days. We investigated long-term trends using a Generalized Additive Model (GAM) after controlling for day of week, month, temperature, wind speed, and relative humidity. In Nicosia, annual PM10 concentrations ranged from 50.4 to 63.8 μg/m3 and exceeded the EU annual standard limit enacted in 2005 of 40 μg/m3 every year A large, statistically significant impact of urban sources (defined as the difference between urban and background levels) was seen in Nicosia over the period 2000-2008, and was highest during traffic hours, weekdays, cold months, and low wind conditions. Our estimate of the mean (standard error) contribution of urban sources to the daily ambient PM10 was 24.0 (0.4) μg/m3. The study of yearly trends showed that PM10 levels in Nicosia decreased from 59.4 μg/m3 in 1993 to 49.0 μg/m3 in 2008, probably in part as a result of traffic emission control policies in Cyprus. In Ayia Marina, annual concentrations ranged from 27.3 to 35.6 μg/m3, and no obvious time trends were observed. The levels measured at the Cyprus background site are comparable to background concentrations reported in other Eastern Mediterranean countries. Average daily PM10 concentrations during desert dust storms were around 100 μg/m3 since 2000 and much higher in earlier years. Despite the large impact ofdust storms and their increasing frequency over time, dust storms were responsible for a small fraction of the exceedances of the daily PM10 limit. Implications: This

  12. The continuing impact of lead dust on children's blood lead: comparison of public and private properties in New Orleans.

    Science.gov (United States)

    Mielke, Howard W; Gonzales, Chris R; Mielke, Paul W

    2011-11-01

    Compared with a maximum collective lead (Pb) estimate of ∼1811 metric tons (MT) in exterior paint on 86,000 New Orleans houses, Pb additives in gasoline were estimated at ∼12,000 MT in New Orleans, yielding ∼9100 MT Pb exhausted as aerosols from vehicles; ∼4850 MT were particles>10 μm and ∼4200 MT were particles New Orleans. This study includes 224 soil samples from 10 public housing properties and 363 soil samples from residential private properties within an 800 m radius of centroids of public housing census tracts. The Louisiana Childhood Lead Poisoning Prevention Program data from 2000 to 2005 (pre-Hurricane Katrina) was the source for 9807 children's blood Pb (μg/dL) results. Soil and blood Pb data were grouped by public housing census tracts and private residential properties. This study uses Multi-Response Permutation Procedures for statistical analysis. Brick public properties in the city core had significantly more soil Pb contamination and higher prevalence of elevated children's blood Pb than same-aged brick public properties in the outer areas of the city. The pre-Hurricane Katrina New Orleans concentration of Pb dust in the inner-city soil displayed a median of 438 mg/kg or 3.7 times larger than Pb dust in outlying areas where the median soil Pb was 117 mg/kg (p-value=2.9×10(-15)). Also, the pre-Hurricane Katrina prevalence of children's blood Pb≥10 μg/dL was 22.9% within the inner-city compared with 9.1% in the outer areas of New Orleans (p-value=3.4×10(-74)). Comparing the quantities of Pb dust from paint and Pb additives to gasoline, this study supports the later source as a more plausible explanation for the differences in soil Pb and children's blood Pb within public and private housing in the higher traffic congested inner-city core compared with the lower traffic congested outer areas of New Orleans. Similar patterns of environmental Pb dust contamination and childhood Pb exposure are expected in all cities. Copyright © 2011

  13. Air-conditioner filters enriching dust mites allergen.

    Science.gov (United States)

    Zhan, Xiaodong; Li, Chaopin; Xu, Haifeng; Xu, Pengfei; Zhu, Haibin; Diao, Jidong; Li, Na; Zhao, Beibei

    2015-01-01

    We detected the concentration of dust mites allergen (Der f1 & Der p1) in the air of different places before and after the starting of air-conditioners in Wuhu City, Anhui, China, and to discuss the relation between the dust mites allergen in air-conditioner filters and the asthma attack. The dust samples were collected from the air-conditioner filters in dining rooms, shopping malls, hotels and households respectively. Concentrations of dust mites major group allergen 1 (Der f 1, Der p1) were detected with enzyme linked immunosorbent assay (ELISA), and the dust mite immune activities were determined by dot-ELISA. The concentration of Der f1 in dining rooms, shopping malls, hotels and households was 1.52 μg/g, 1.24 μg/g, 1.31 μg/g and 1.46 μg/g respectively, and the concentration of Der p1 in above-mentioned places was 1.23 μg/g, 1.12 μg/g, 1.16 μg/g and 1.18 μg/g respectively. The concentration of Der f1 & Der p1 in air was higher after the air-conditioners starting one hours later, and the difference was significant (Pair-conditioner filters can enrich dust mites major group allergen, and the allergens can induce asthma. The air-conditioner filters shall be cleaned or replaced regularly to prevent or reduce accumulation of the dust mites and its allergens.

  14. Dust Effect on The Performance of Optical Wireless Communication System

    Directory of Open Access Journals (Sweden)

    Fadel Abdul-Zahra Murad

    2017-11-01

    Full Text Available In this paper wireless optical communication system (FSO is designed through the use of software (Optisystem . The paper also study  the effect of atmospheric dust on the performance of communication system (FSO, the effect of dust concentration on the visibility by taking a different concentrations of dust (9, 20, 40, 60, 80 100, 120 gm / month / m2 . The effect of the visibility on the attenuation of dust concentration on each of these concentrations , and calculate attenuation of dust for the  wavelengths  (784 nm, 1550 nm. The Paper also deals with effect of the transmitted laser  power on the transmitter range (propagation distance where five different values of transmitted laser power (10mw, 20mw, 30mw, 40mw, 50mw are taken  and the study calculates the maximum transmitter range of  each value of the transmitted power under the influence of attenuation atmospheric dust concentrations for each concentration of dust used and also for the two wavelengths (1550nm, 784nm.

  15. Identification of lead sources in residential environments: Sydney Australia

    International Nuclear Information System (INIS)

    Laidlaw, M.A.S.; Zahran, S.; Pingitore, N.; Clague, J.; Devlin, G.; Taylor, M.P.

    2014-01-01

    Interior and exterior dust, soil and paint were analysed at five brick urban Sydney homes over 15 months to evaluate temporal variations and discriminate sources of lead (Pb) exposure. Exterior dust gauge Pb loading rates (μg/m 2 /28 days), interior vacuum dust Pb concentrations (mg/kg) and interior petri-dish Pb loading rates (μg/m 2 /28 days), were correlated positively with soil Pb concentrations. Exterior dust gauge Pb loading rates and interior vacuum dust Pb concentrations peaked in the summer. Lead isotope and Pb speciation (XAS) were analysed in soil and vacuum dust samples from three of the five houses that had elevated Pb concentrations. Results show that the source of interior dust lead was primarily from soil in two of the three houses and from soil and Pb paint in the third home. IEUBK child blood Pb modelling predicts that children's blood Pb levels could exceed 5 μg/dL in two of the five houses. -- Highlights: • Exterior Pb loading and interior Pb dust loading and concentrations correlate with soil Pb. • Exterior dust gauge Pb loading rates and interior vacuum dust Pb concentrations peak in the summer. • Interior dust lead came from soil in two of the three houses and from soil and Pb paint in the third home. • Modelling predicts that children's blood Pb levels could exceed 5 μg/dL in two of the five houses. -- Interior and exterior dust, soil and paint were analysed at five brick urban Sydney homes over 15 months to evaluate temporal variations and discriminate sources of lead (Pb) exposure

  16. The effect of house design and environment on fungal movement in homes of bronchial asthma patients.

    Science.gov (United States)

    Takatori, K; Saito, A; Yasueda, H; Akiyama, K

    2001-01-01

    The effect of house building design and environment on the fungal movement in the houses of 41 bronchial asthma (BA) patients has been investigated by examining house dust. The presence and composition of fungi were determined and compared in relation to building structure, house age, size of living room, main flooring material, presence of a living-room rug or air purifier, and frequency of vacuum cleaning. Among these elements, fungal CFU apparently varied only between building structure: wooden-board houses had significantly higher numbers of fungi than reinforced concrete houses (p prefabricated houses had significantly higher numbers of fungi than reinforced concrete houses (p < 0.05). Classification of the types of fungi present in the house dust of BA patients showed that, regardless of the building designs, there were high levels of osmophilic fungi (group A) and fungi that survive at relatively dry conditions (group B), whereas fungi that survive in very wet conditions (group D) were present at low frequency.

  17. Dust in planetary nebulae

    International Nuclear Information System (INIS)

    Mathis, J.S.

    1978-01-01

    The author's review concentrates on theoretical aspects of dust in planetary nebulae (PN). He considers the questions: how much dust is there is PN; what is its composition; what effects does it have on the ionization structure, on the dynamics of the nebula. (Auth.)

  18. Aspergillus, Penicillium and Talaromyces isolated from house dust samples collected around the world

    NARCIS (Netherlands)

    Visagie, C M; Hirooka, Y; Tanney, J B; Whitfield, E; Mwange, K; Meijer, M; Amend, A S; Seifert, K A; Samson, R A

    As part of a worldwide survey of the indoor mycobiota, dust was collected from nine countries. Analyses of dust samples included the culture-dependent dilution-to-extinction method and the culture-independent 454-pyrosequencing. Of the 7 904 isolates, 2 717 isolates were identified as belonging to

  19. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece

    International Nuclear Information System (INIS)

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-01-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑ 21 PBDE) in A/C dust ranged between 84 and 4062 ng g −1 with a median value of 1092 ng g −1 , while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day −1 (median 12 ng day −1 ). - Highlights: • PBDEs were investigated in dust of A/C filters in occupational settings in Thessaloniki, Greece. • BDE-209 was found to be the most abundant BDE congener. • High levels of PBDEs were found in a newspaper building, internet cafes and electronic shops. • PBDEs were attributable to the extensive presence and/or usage of electronic devices. • Exposure of employees to PBDEs via indoor dust ingestion was estimated at 12 ng day −1 . - PBDEs were for the first time measured in dust from central A/C filters in workplaces of Greece and their concentrations were used to estimate the non-dietary human exposure

  20. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    Science.gov (United States)

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the

  1. Genetically engineered Lactococcus lactis protect against house dust mite allergy in a BALB/c mouse model.

    Directory of Open Access Journals (Sweden)

    Chunqing Ai

    Full Text Available Mucosal vaccine based on lactic acid bacteria is an attractive concept for the prevention and treatment of allergic diseases, but their mechanisms of action in vivo are poorly understood. Therefore, we sought to investigate how recombinant major dust mite allergen Der p2-expressing Lactococcus lactis as a mucosal vaccine induced the immune tolerance against house dust mite allergy in a mouse model.Three strains of recombinant L. lactis producing Der p2 in different cell components (extracellular, intracellular and cell wall were firstly constructed. Their prophylactic potential was evaluated in a Der p2-sensitised mouse model, and immunomodulation properties at the cellular level were determined by measuring cytokine production in vitro.Der p2 expressed in the different recombinant L. lactis strains was recognized by a polyclonal anti-Der p2 antibody. Oral treatment with the recombinant L. lactis prior sensitization significantly prevented the development of airway inflammation in the Der p2-sensitized mice, as determined by the attenuation of inflammatory cells infiltration in the lung tissues and decrease of Th2 cytokines IL-4 and IL-5 levels in bronchoalveolar lavage. In addition, the serum allergen-specific IgE levels were significantly reduced, and the levels of IL-4 in the spleen and mesenteric lymph nodes cell cultures were also markedly decreased upon allergen stimulation in the mice fed with the recombinant L. lactis strains. These protective effects correlated with a significant up-regulation of regulatory T cells in the mesenteric lymph nodes.Oral pretreatment with live recombinant L. lactis prevented the development of allergen-induced airway inflammation primarily by the induction of specific mucosal immune tolerance.

  2. Lead in residential soil and dust in a mining and smelting district in northern Armenia: a pilot study

    International Nuclear Information System (INIS)

    Petrosyan, Varduhi; Orlova, Anna; Dunlap, Charles E.; Babayan, Emil; Farfel, Mark; Braun, Margrit von

    2004-01-01

    This pilot study of sources of lead exposure in residential settings was conducted in a mining and smelting district in northern Armenia. Samples of exterior soil and dust and interior house dust were collected in and around apartment buildings in Alaverdi where the country's largest polymetallic smelter is located, and in nearby mining towns of Aghtala and Shamlugh. The NITON XL-723 Multi-Element XRF analyzer was used for lead testing. Lead levels in samples from Alaverdi were higher than those in Shamlugh and Aghtala. In all three towns, the highest lead levels were found in loose exterior dust samples, and lead concentrations in yard soil were higher than those in garden soil. Many soil samples (34%) and the majority of loose dust samples (77%) in Alaverdi exceeded the US Environmental Protection Agency standard of 400 mg/kg for bare soil in children's play areas. In addition, 36% of floor dust samples from apartments in Alaverdi exceeded the US Environmental Protection Agency standard of 40 μg/ft 2 for lead loading in residential floor dust. The Armenian Ministry of Health and other interested agencies are being informed about the findings of the study so that they can consider and develop educational and preventive programs including blood lead screening among sensitive populations

  3. Concentrations of legacy and novel brominated flame retardants in indoor dust in Melbourne, Australia: An assessment of human exposure.

    Science.gov (United States)

    McGrath, Thomas J; Morrison, Paul D; Ball, Andrew S; Clarke, Bradley O

    2018-04-01

    Polybrominated diphenyl ethers (PBDEs) and novel brominated flame retardants (NBFR) have been used in a range of polymers to inhibit the spread of fires but also have a propensity to migrate out of consumer materials and contaminate indoor dust. In this study, a total of 57 dust samples were collected from 12 homes, eight offices and eight vehicles in Melbourne, Australia and analysed for eight PBDEs (-28, -47, -99, -100, -153, -154, -183 and -209) and seven NBFRs (PBT, PBEB, HBB, EH-TBB, BEH-TEBP, BTBPE and DBDPE) to determine human exposure risks from dust ingestion. Samples were analysed using selective pressurized liquid extraction (S-PLE) and gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). Legacy and replacement flame retardants were detected in all samples with overall ∑PBDE concentrations ranging from 120 to 1700,000 ng/g (median 2100 ng/g) and ∑NBFRs ranging from 1.1 to 10,000 ng/g (median 1800 ng/g). BDE-209 and DBDPE were the dominant compounds in dust samples, followed by congeners associated with commercial Penta-BDE formulations (-47, -99, -100, -153 and -154) and then EH-TBB of the FireMaster 550 and BZ-54 products. ∑Penta-BDE concentrations were elevated in office samples compared with homes and vehicles, while EH-TBB and BDE-209 measured higher concentrations in vehicles compared with their respective levels in homes and offices. Risk assessment estimates revealed the majority of exposure to occur in the home for both adults and toddlers in the City of Melbourne. Generally, body weight adjusted exposure to PBDEs and NBFRs was predicted to be 1 to 2 orders of magnitude higher for toddlers than adults. Estimated rates of BDE-47, -99, -153 and -209 ingestion were each 2 orders of magnitude or more below the USEPA's prescribed oral reference dose values (RfDs) for typical exposure scenarios. However, exposure rates for BDE-47 and -99 reached as high as 52 and 95% of RfDs, respectively, for adults and 4.4 and 7

  4. Estimation of the in vitro eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust by using reconstituted human corneal epithelium tissue cultures.

    Science.gov (United States)

    Cao, Yi; Bindslev, Dorthe A; Kjærgaard, Søren K

    2015-01-01

    Eye irritation is a common complaint in indoor environment, but the causes have still not been identified among the multiple exposures in house environments. To identify the potential environmental factors responsible for eye irritation and study the possible mechanisms, an in vitro model for eye irritation is suggested. In this study, reconstituted human corneal epithelium (HCE) tissue cultures were used to study the eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust. HCE tissue cultures were exposed to a range of concentrations of LPS for 6 h and dust for 24 h, respectively. After exposure, viability and secretion of interleukins (IL) IL-1β, IL-8, and tumor necrosis factor (TNFα) were examined. Histology was used to indicate the morphological changes after dust exposure. Both LPS and dust affected HCE viability. There was an increased level of IL-8 after LPS exposure, while the concentrations of IL-1β and TNFα remained unaffected. Dust exposure resulted in an elevation of both IL-1β and IL-8, but not TNFα. Histology study showed increased vacuolization and reduced thickness after 24 h exposure to 5 mg/mL dust. LPS and dust showed in vitro eye irritating and inflammatory potential, and cytokines/chemokines like IL-1β and IL-8 may be involved in the mechanisms of eye irritation. The HCE tissue culture may be used as an in vitro model to study environmental exposure induced eye irritation and inflammation.

  5. Fipronil and its degradates in indoor and outdoor dust

    Science.gov (United States)

    Mahler, B.J.; Van Metre, P.C.; Wilson, J.T.; Musgrove, M.; Zaugg, S.D.; Burkhardt, M.R.

    2009-01-01

    Fipronil is a potent insecticide used for control of termites, fleas, roaches, ants, and other pests. We measured fipronil, fipronil sulfide, and desulfinyl fipronil concentrations in indoor and outdoor dust from 24 residences in Austin, Texas. At least one of these three fipronil compounds was detected in every sample. Fipronil accounted for most of the total fipronil (T-fipronil; fipronil+desulfinyl fipronil+fipronil sulfide), followed by desulfinyl fipronil and fipronil sulfide. Nineteen of 24 samples of indoor dust had T-fipronil concentrations less than 270 ??g/kg; the remaining five had concentrations from 1320 to 14,200 ??g/kg. All three of the residences with a dog on which a flea-control product containing fipronil was used were among the five residences with elevated fipronil concentrations. In outdoor dust, all concentrations of T-fipronil were less than 70??g/kg with one exception (430??g/kg). For every residence, the concentration of T-fipronil in indoor dust exceeded that in outdoor dust, and the median concentration of T-fipronil was 15 times higher indoors than outdoors.

  6. Paradoxical effects of rapamycin on experimental house dust mite-induced asthma.

    Directory of Open Access Journals (Sweden)

    Karin Fredriksson

    Full Text Available The mammalian target of rapamycin (mTOR modulates immune responses and cellular proliferation. The objective of this study was to assess whether inhibition of mTOR with rapamycin modifies disease severity in two experimental murine models of house dust mite (HDM-induced asthma. In an induction model, rapamycin was administered to BALB/c mice coincident with nasal HDM challenges for 3 weeks. In a treatment model, nasal HDM challenges were performed for 6 weeks and rapamycin treatment was administered during weeks 4 through 6. In the induction model, rapamycin significantly attenuated airway inflammation, airway hyperreactivity (AHR and goblet cell hyperplasia. In contrast, treatment of established HDM-induced asthma with rapamycin exacerbated AHR and airway inflammation, whereas goblet cell hyperplasia was not modified. Phosphorylation of the S6 ribosomal protein, which is downstream of mTORC1, was increased after 3 weeks, but not 6 weeks of HDM-challenge. Rapamycin reduced S6 phosphorylation in HDM-challenged mice in both the induction and treatment models. Thus, the paradoxical effects of rapamycin on asthma severity paralleled the activation of mTOR signaling. Lastly, mediastinal lymph node re-stimulation experiments showed that treatment of rapamycin-naive T cells with ex vivo rapamycin decreased antigen-specific Th2 cytokine production, whereas prior exposure to in vivo rapamycin rendered T cells refractory to the suppressive effects of ex vivo rapamycin. We conclude that rapamycin had paradoxical effects on the pathogenesis of experimental HDM-induced asthma. Thus, consistent with the context-dependent effects of rapamycin on inflammation, the timing of mTOR inhibition may be an important determinant of efficacy and toxicity in HDM-induced asthma.

  7. Antibiotics in dust originating from a pig-fattening farm: a new source of health hazard for farmers?

    Science.gov (United States)

    Hamscher, Gerd; Pawelzick, Heike Theresia; Sczesny, Silke; Nau, Heinz; Hartung, Jörg

    2003-10-01

    Pig-house dust originates from feed, bedding, feces, and the animals themselves. If the animals receive drugs such as antibiotics, residues of these substances may occur in manure, in the air, or on surfaces of the respective animal house. In a retrospective study, we investigated dust samples collected during two decades from the same piggery for the occurrence of various antibiotics. In 90% of these samples, we detected up to five different antibiotics, including tylosin, various tetracyclines, sulfamethazine, and chloramphenicol, in total amounts up to 12.5 mg/kg dust. High dust exposure in animal confinement buildings is believed to be a respiratory health hazard because of the high content of microorganisms, endotoxins, and allergens. Further risks may arise from the inhalation of dust contaminated with a cocktail of antibiotics. Apart from that, our data provide first evidence for a new route of entry for veterinary drugs in the environment.

  8. House dust mite allergen Der p 1 effects on sinonasal epithelial tight junctions.

    Science.gov (United States)

    Henriquez, Oswaldo A; Den Beste, Kyle; Hoddeson, Elizabeth K; Parkos, Charles A; Nusrat, Asma; Wise, Sarah K

    2013-08-01

    Epithelial permeability is highly dependent upon the integrity of tight junctions, which are cell-cell adhesion complexes located at the apical aspect of the lateral membrane of polarized epithelial cells. We hypothesize that sinonasal epithelial exposure to Der p 1 house dust mite antigen decreases expression of tight junction proteins (TJPs), representing a potential mechanism for increased permeability and presentation of antigens across the sinonasal epithelial layer. Confluent cultured primary human sinonasal epithelial cells were exposed to recombinant Der p 1 antigen vs control, and transepithelial resistance measurements were performed over 24 hours. Antibody staining for a panel of TJPs was examined with immunofluorescence/confocal microscopy and Western blotting. Tissue for these experiments was obtained from 4 patients total. Der p 1 exposed sinonasal cells showed a marked decrease in transepithelial resistance when compared to control cells. In addition, results of Western immunoblot and immunofluorescent labeling demonstrated decreased expression of TJPs claudin-1 and junction adhesion molecule-A (JAM-A) in Der p 1-exposed cultured sinonasal cells vs controls. Der p 1 antigen exposure decreases sinonasal epithelium TJP expression, most notably seen in JAM-A and claudin-1 in these preliminary experiments. This decreased TJP expression likely contributes to increased epithelial permeability and represents a potential mechanism for transepithelial antigen exposure in allergic rhinitis. © 2013 ARS-AAOA, LLC.

  9. Dust exposure and pneumoconiosis in a South African pottery. 1. Study objectives and dust exposure.

    Science.gov (United States)

    Rees, D; Cronje, R; du Toit, R S

    1992-07-01

    Dust exposure and pneumoconiosis were investigated in a South African pottery that manufactured wall tiles and bathroom fittings. This paper describes the objectives of the investigation and presents dust measurement data. x Ray diffraction showed that the clays used by the pottery had a high quartz content (range 58%-23%, mean 38%). Exposure to respirable dust was measured for 43 workers and was highest (6.6 mg/m3) in a bathroom fitting fettler. Quartz concentrations in excess of 0.1 mg/m3 were found in all sections of the manufacturing process from slip production to biscuit firing and sorting. The proportion of quartz in the respirable dust of these sections was 24% to 33%. This is higher than is usually reported in English potteries. Four hundred and six (80%) of the 509 workers employed at the pottery were potentially at risk of occupational lung disease. The finding of large numbers of pottery workers exposed to unacceptable dust concentrations is not surprising as poor dust control was found in all six wall tile and sanitary ware factories surveyed by the National Centre for Occupational Health between 1973 and 1989. Dust related occupational disease can be expected in potters for many years to come.

  10. A STUDY OF FISCHER 344 RATS EXPOSED TO SILICA DUST FOR SIX MONTHS AT CONCENTRATIONS OF 0, 2, 10 OR 20 MG / M3.

    Energy Technology Data Exchange (ETDEWEB)

    KUTZMAN,R.S.

    1984-02-01

    The major objective of this study was to relate the results of a series of functional tests to the compositional and structural alterations in the rat lung induced by subchronic exposure to silica dust. Fischer-344 rats were exposed for 6 hours/day, 5 days/week for 6 months to either 0, 2, 10, or 20 mg SiO{sub 2}/m{sup 3}. The general appearance of the exposed rats was not different from that of the controls. Interestingly, female rats exposed to silica dust, at all tested concentrations, gained more weight than the controls. The lung weight and the lung-to-body weight ratio was greater in the male rats exposed to the highest concentration of silica dust.

  11. Volatile Organic Compound Concentrations and Emission Rates in New Manufactured and Site-Built Houses

    Energy Technology Data Exchange (ETDEWEB)

    Armin Rudd

    2008-10-30

    This study was conducted with the primary objective of characterizing and comparing the airborne concentrations and the emission rates of total VOCs and selected individual VOCs, including formaldehyde, among a limited number of new manufactured and site-built houses.

  12. Respirable quartz hazard associated with coal mine roof bolter dust

    International Nuclear Information System (INIS)

    Joy, G.J.; Beck, T.W.; Listak, J.M.

    2010-01-01

    Pneumoconiosis has been reported to be increasing among underground coal miners in the Southern Appalachian Region. The National Institute for Occupational Safety and Health conducted a study to examine the particle size distribution and quartz content of dust generated by the installation of roof bolts in mines. Forty-six bulk samples of roof bolting machine pre-cleaner cyclone dump dust and collector box dust were collected from 26 underground coal mines. Real-time and integrated airborne respirable dust concentrations were measured on 3 mining sections in 2 mines. The real-time airborne dust concentrations profiles were examined to identify any concentration changes that might be associated with pre-cleaner cyclone dust discharge events. The study showed that bolter dust is a potential inhalation hazard due to the fraction of dust less than 10 μm in size, and the quartz content of the dust. The pre-cleaner cyclone dust was significantly larger than the collector box dust, indicating that the pre-cleaner functioned properly in removing the larger dust size fraction from the airstream. However, the pre-cleaner dust still contained a substantial amount of respirable dust. It was concluded that in order to maintain the effectiveness of a roof bolter dust collector, periodic removal of dust is required. Appropriate work procedures and equipment are necessary to minimize exposure during this cleaning task. 13 refs., 3 tabs., 2 figs.

  13. Lepidoglyphus destructor acarus in the urban house environment.

    Science.gov (United States)

    Juliá, J C; Martorell, A; Ventas, P; Cerdá, J C; Torró, I; Carreira, J; Guinot, E; Sanz, J; Alvarez, V

    1995-01-01

    To assess the presence of Lepidoglyphus destructor in the household environment of sensitized children living in an urban environment, samples of house dust were collected at the homes where two groups of patients were living, as well as in two bakeries in the city of Valencia, which were taken as a reference. Patients were divided into two groups. Group A included atopic children suffering from rhinitis and/or asthma, who were sensitized to L. destructor, as proven by prick test and specific IgE (CAP). Group B included children with the same features as those included in Group A, who were sensitized to Dermatophagoides pteronyssinus, with prick and CAP tests showing no significant sensitization to L. destructor. The samples of dust were analyzed, and the amounts of Der p I, Der f I, Der II and Lep d I per gram of dust were assessed through a solid-phase ELISA with monoclonal antibodies. In Group A, all patients but two showed a sensitization to D. pteronyssinus by prick test and serum IgE. At the homes of the patients from both groups, significant levels of Dermatophagoides were found. In Group A, only three houses showed levels of L. destructor which were comparable to those found in bakeries. Lep d I was not found in the houses of Group B patients. This means that a sensitization to L. destructor, as assessed with full extracts, is not always an indicator of its presence at the patient's house environment; it may rather refer to cross-reactivity to Dermatophagoides. Thus, availability of the main antigen Lep d I seems necessary to increase the specificity of the allergologic study.

  14. Assessment of current techniques for reduction of indoor radon concentration in existing and new houses in European countries

    International Nuclear Information System (INIS)

    Holmgren, O.; Arvela, H.

    2012-03-01

    Radon control technologies aim at the reduction of indoor radon concentrations in existing buildings and in new construction through remedial and preventive measures. In recent years, rising ecological awareness and rising energy costs have stimulated the development of low energy and passive houses to save energy. This report contains the analysis and assessment of current techniques and technologies used to achieve the reduction of indoor radon concentrations in existing and new houses with regard to the reduction efficiency and potential impact on energy consumption (qualitative analysis). A questionnaire was prepared and sent to all RADPAR partners in 14 different countries in order to gather national information about the current remediation and prevention techniques. Responses with variable amounts of information were obtained. Based on the questionnaire responses, the status of radon remediation and prevention in each country was assessed, in addition to the reduction efficiency and potential impact on energy consumption of the current remediation and prevention techniques. The number of dwellings with an elevated indoor radon concentration typically ranges from tens of thousands to a million. The percentage of these houses already remediated varies from zero to 15%. Preventive measures in new construction have been taken from a small number of houses to over half a million houses. The research data on the current situation, the number of houses with preventive measures and the efficiency of these measures is currently still quite inadequate. Assessment of the techniques and also the surveys aiming at exploring the impact of remedial and preventive measures is greatly needed in order to promote the work at the national level. The most efficient remediation method is the active sub-slab depressurization (SSD) and the radon well, for which the reduction in the radon concentration is typically 70 - 95%. Other methods, such as sealing entry routes and improving

  15. Asian dust events of April 1998

    Science.gov (United States)

    Husar, R.B.; Tratt, D.M.; Schichtel, B.A.; Falke, S.R.; Li, F.; Jaffe, D.; Gasso, S.; Gill, T.; Laulainen, N.S.; Lu, F.; Reheis, M.C.; Chun, Y.; Westphal, D.; Holben, B.N.; Gueymard, C.; McKendry, I.; Kuring, N.; Feldman, G.C.; McClain, C.; Frouin, R.J.; Merrill, J.; DuBois, D.; Vignola, F.; Murayama, T.; Nickovic, S.; Wilson, W.E.; Sassen, K.; Sugimoto, N.; Malm, W.C.

    2001-01-01

    On April 15 and 19, 1998, two intense dust storms were generated over the Gobi desert by springtime low-pressure systems descending from the northwest. The windblown dust was detected and its evolution followed by its yellow color on SeaWiFS satellite images, routine surface-based monitoring, and through serendipitous observations. The April 15 dust cloud was recirculating, and it was removed by a precipitating weather system over east Asia. The April 19 dust cloud crossed the Pacific Ocean in 5 days, subsided to the surface along the mountain ranges between British Columbia and California, and impacted severely the optical and the concentration environments of the region. In east Asia the dust clouds increased the albedo over the cloudless ocean and land by up to 10-20%, but it reduced the near-UV cloud reflectance, causing a yellow coloration of all surfaces. The yellow colored backscattering by the dust eludes a plausible explanation using simple Mie theory with constant refractive index. Over the West Coast the dust layer has increased the spectrally uniform optical depth to about 0.4, reduced the direct solar radiation by 30-40%, doubled the diffuse radiation, and caused a whitish discoloration of the blue sky. On April 29 the average excess surface-level dust aerosol concentration over the valleys of the West Coast was about 20-50 ??g/m3 with local peaks >100 ??g/m3. The dust mass mean diameter was 2-3 ??m, and the dust chemical fingerprints were evident throughout the West Coast and extended to Minnesota. The April 1998 dust event has impacted the surface aerosol concentration 2-4 times more than any other dust event since 1988. The dust events were observed and interpreted by an ad hoc international web-based virtual community. It would be useful to set up a community-supported web-based infrastructure to monitor the global aerosol pattern for such extreme aerosol events, to alert and to inform the interested communities, and to facilitate collaborative

  16. Raman spectroscopic analysis of the carotenoid concentration in egg yolks depending on the feeding and housing conditions of the laying hens.

    Science.gov (United States)

    Hesterberg, Karoline; Schanzer, Sabine; Patzelt, Alexa; Sterry, Wolfram; Fluhr, Joachim W; Meinke, Martina C; Lademann, Jürgen; Darvin, Maxim E

    2012-01-01

    Resonance Raman spectroscopic measurements are suited to analyze the concentration of carotenoid antioxidants in biological samples. Previously, it has been shown that the carotenoid concentration of nutritional egg yolks has a direct influence on the carotenoid content of human skin in vivo. In the present study, resonance Raman spectroscopy was used to analyze the carotenoid concentration in the yolks of hen eggs, which were housed in battery cages or alternatively on free-range grassland. The egg yolks of hens, which had access to grassland, contained approximately double the amount of carotenoid concentration than the egg yolks of hens housed in battery cages (p egg yolks, depending on fodder, housing and weather conditions, were investigated. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Exposure to dust and its particle size distribution in shoe manufacture and repair workplaces measured with GRIMM laser dust monitor.

    Science.gov (United States)

    Stroszejn-Mrowca, Grazyna; Szadkowska-Stańczyk, Irena

    2003-01-01

    Owing to a diversified technological process and a great variety of products and materials used in shoe manufacture, workers may be exposed to dusts that contain different chemicals and particles of various shapes and sizes. The aim of this study was to assess the dust exposure, taking account of concentration of particular size fractions according to the European Standard Norm, and to analyze particle size distribution in inhalable dust at selected workplaces in a modern shoe manufacture plant and in a small shoe repair workshop in comparison with other industrial branches. In these two workplaces, the concentrations of dust, representing the inhalable, thoracic, and respirable fractions, were measured with the GRIMM 1.105 laser dust monitor. The particle size distribution in inhaled dust in the most characteristic workposts was analyzed. In the shoe manufacture plant, the concentrations ranged from 124 microg/m3 (leather cutting out) to 724 microg/m3 (scouring and milling of soles); concentrations of the thoracic and respirable fractions in the same workposts ranged from 74 microg/m3 to 412 microg/m3 and from 24 microg/m3 to 120 microg/m3, respectively. In the shoe repair workshop, the recorded concentrations were higher: the values ranged from 521 microg/m3 (gluing of shoes and soles, zipper exchange and heel abrasion) to 916 microg/m3 (uppers sewing and heel scouring) for the inhaled fraction; from 335 microg/m3 to 499 microg/m3 for the thoracic fraction; and from 88 microg/m3 to 120 microg/m3 for the respirable fraction. The mass median aerodynamic diameters of inhalable dust particles fell within the limits of 6.2-25.0 mm. Dust with the smallest particles (MMAD = 6.2 mm) was observed in shoe brushing and polishing, and with the largest particles (MMAD = 25.0 mm) in uppers sewing. The modern process of shoe manufacture is characterized by very low concentrations of inhalable dust and its fractions, they are considerably lower than occupational exposure limits

  18. Potential human exposure to halogenated flame-retardants in elevated surface dust and floor dust in an academic environment

    International Nuclear Information System (INIS)

    Allgood, Jaime M.; Jimah, Tamara; McClaskey, Carolyn M.; La Guardia, Mark J.; Hammel, Stephanie C.; Zeineddine, Maryam M.; Tang, Ian W.; Runnerstrom, Miryha G.; Ogunseitan, Oladele A.

    2017-01-01

    Most households and workplaces all over the world possess furnishings and electronics, all of which contain potentially toxic flame retardant chemicals to prevent fire hazards. Indoor dust is a recognized repository of these types of chemicals including polybrominated diphenyl ethers (PBDEs) and non-polybrominated diphenyl ethers (non-PBDEs). However, no previous U.S. studies have differentiated concentrations from elevated surface dust (ESD) and floor dust (FD) within and across microenvironments. We address this information gap by measuring twenty-two flame-retardant chemicals in dust on elevated surfaces (ESD; n=10) and floors (FD; n=10) from rooms on a California campus that contain various concentrations of electronic products. We hypothesized a difference in chemical concentrations in ESD and FD. Secondarily, we examined whether or not this difference persisted: (a) across the studied microenvironments and (b) in rooms with various concentrations of electronics. A Wilcoxon signed-rank test demonstrated that the ESD was statistically significantly higher than FD for BDE-47 (p=0.01), BDE-99 (p=0.01), BDE-100 (p=0.01), BDE-153 (p=0.02), BDE-154 (p=0.02), and 3 non-PBDEs including EH-TBB (p=0.02), BEH-TEBP (p=0.05), and TDCIPP (p=0.03). These results suggest different levels and kinds of exposures to flame-retardant chemicals for individuals spending time in the sampled locations depending on the position of accumulated dust. Therefore, further research is needed to estimate human exposure to flame retardant chemicals based on how much time and where in the room individuals spend their time. Such sub-location estimates will likely differ from assessments that assume continuous unidimensional exposure, with implications for improved understanding of potential health impacts of flame retardant chemicals. - Highlights: • Brominated flame retardants used in electronic products accumulate in room dust • Various chemical moieties of flame retardants leach

  19. Potential human exposure to halogenated flame-retardants in elevated surface dust and floor dust in an academic environment

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, Jaime M.; Jimah, Tamara [Department of Population Health & Disease Prevention, Program in Public Health, University of California, Irvine, CA 92697-3957 (United States); McClaskey, Carolyn M. [Department of Cognitive Sciences, School of Social Sciences, University of California, Irvine, CA 92697-5100 (United States); La Guardia, Mark J. [Department of Aquatic Health Sciences, Virginia Institute of Marine Science, College of William and Mary, Gloucester Point, VA 23062 (United States); Hammel, Stephanie C.; Zeineddine, Maryam M.; Tang, Ian W.; Runnerstrom, Miryha G. [Department of Population Health & Disease Prevention, Program in Public Health, University of California, Irvine, CA 92697-3957 (United States); Ogunseitan, Oladele A., E-mail: Oladele.Ogunseitan@uci.edu [Department of Population Health & Disease Prevention, Program in Public Health, University of California, Irvine, CA 92697-3957 (United States)

    2017-02-15

    Most households and workplaces all over the world possess furnishings and electronics, all of which contain potentially toxic flame retardant chemicals to prevent fire hazards. Indoor dust is a recognized repository of these types of chemicals including polybrominated diphenyl ethers (PBDEs) and non-polybrominated diphenyl ethers (non-PBDEs). However, no previous U.S. studies have differentiated concentrations from elevated surface dust (ESD) and floor dust (FD) within and across microenvironments. We address this information gap by measuring twenty-two flame-retardant chemicals in dust on elevated surfaces (ESD; n=10) and floors (FD; n=10) from rooms on a California campus that contain various concentrations of electronic products. We hypothesized a difference in chemical concentrations in ESD and FD. Secondarily, we examined whether or not this difference persisted: (a) across the studied microenvironments and (b) in rooms with various concentrations of electronics. A Wilcoxon signed-rank test demonstrated that the ESD was statistically significantly higher than FD for BDE-47 (p=0.01), BDE-99 (p=0.01), BDE-100 (p=0.01), BDE-153 (p=0.02), BDE-154 (p=0.02), and 3 non-PBDEs including EH-TBB (p=0.02), BEH-TEBP (p=0.05), and TDCIPP (p=0.03). These results suggest different levels and kinds of exposures to flame-retardant chemicals for individuals spending time in the sampled locations depending on the position of accumulated dust. Therefore, further research is needed to estimate human exposure to flame retardant chemicals based on how much time and where in the room individuals spend their time. Such sub-location estimates will likely differ from assessments that assume continuous unidimensional exposure, with implications for improved understanding of potential health impacts of flame retardant chemicals. - Highlights: • Brominated flame retardants used in electronic products accumulate in room dust • Various chemical moieties of flame retardants leach

  20. Size fraction effect on phthalate esters accumulation, bioaccessibility and in vitro cytotoxicity of indoor/outdoor dust, and risk assessment of human exposure.

    Science.gov (United States)

    Wang, Wei; Wu, Fu-Yong; Huang, Min-Juan; Kang, Yuan; Cheung, Kwai Chung; Wong, Ming Hung

    2013-10-15

    Indoor and outdoor dusts from two urban centers in the Pearl River Delta, China, were analyzed and phthalate esters varied from 4.95 to 2,220 μg g(-1) in indoor dust, significantly higher than outdoor dust (1.70-869 μg g(-1)). Di-2-ethylhexyl phthalate (DEHP) was the dominant phthalate found and the highest distribution factor (DF) (1.56 ± 0.41) was noted in the human T cell lymphoblast leukemic cell line (CCRF-CEM) indicated by Lethal Concentration 50 (LC50) decreased with particle size. The power model was found as a better fit for explaining the relationship between LC50 and phthalates (R(2)=0.46, passessment indicated that indoor dust ingestion accounted for the major source for DEHP exposure (81.4-96.4% of non-dietary exposure and 36.5% of total exposure), especially for toddlers. The cancer risks associated with DEHP via home dust were high (10(-6)-10(-4)), with 10% of houses estimated with unacceptable risks (>10(-4)). After corrected with the bioaccessibility of phthalates, the cancer risks of dust exposure were moderate (10(-7)-10(-5)). Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Antibiotics in dust originating from a pig-fattening farm: a new source of health hazard for farmers?

    OpenAIRE

    Hamscher, Gerd; Pawelzick, Heike Theresia; Sczesny, Silke; Nau, Heinz; Hartung, Jörg

    2003-01-01

    Pig-house dust originates from feed, bedding, feces, and the animals themselves. If the animals receive drugs such as antibiotics, residues of these substances may occur in manure, in the air, or on surfaces of the respective animal house. In a retrospective study, we investigated dust samples collected during two decades from the same piggery for the occurrence of various antibiotics. In 90% of these samples, we detected up to five different antibiotics, including tylosin, various tetracycli...

  2. Airborne concentrations of metals and total dust during solid catalyst loading and unloading operations at a petroleum refinery.

    Science.gov (United States)

    Lewis, Ryan C; Gaffney, Shannon H; Le, Matthew H; Unice, Ken M; Paustenbach, Dennis J

    2012-09-01

    Workers handle catalysts extensively at petroleum refineries throughout the world each year; however, little information is available regarding the airborne concentrations and plausible exposures during this type of work. In this paper, we evaluated the airborne concentrations of 15 metals and total dust generated during solid catalyst loading and unloading operations at one of the largest petroleum refineries in the world using historical industrial hygiene samples collected between 1989 and 2006. The total dust and metals, which included aluminum, cadmium, chromium, cobalt, copper, iron, lead, manganese, molybdenum, nickel, platinum, silicon, silver, vanadium, and zinc, were evaluated in relation to the handling of four different types of solid catalysts associated with three major types of catalytic processes. Consideration was given to the known components of the solid catalysts and any metals that were likely deposited onto them during use. A total of 180 analytical results were included in this analysis, representing 13 personal and 54 area samples. Of the long-term personal samples, airborne concentrations of metals ranged from refinery and perhaps other modern refineries during the timeframe examined. Copyright © 2011 Elsevier GmbH. All rights reserved.

  3. Concentrations of Semivolatile Organic Compounds Associated with African Dust Air Masses in Mali, Cape Verde, Trinidad and Tobago, and the U.S. Virgin Islands, 2001-2008

    Science.gov (United States)

    Garrison, Virginia H.; Foreman, William T.; Genualdi, Susan A.; Majewski, Michael S.; Mohammed, Azad; Simonich, Staci Massey

    2011-01-01

    Every year, billions of tons of fine particles are eroded from the surface of the Sahara Desert and the Sahel of West Africa, lifted into the atmosphere by convective storms, and transported thousands of kilometers downwind. Most of the dust is carried west to the Americas and the Caribbean in the Saharan Air Layer (SAL). Dust air masses predominately impact northern South America during the Northern Hemisphere winter and the Caribbean and Southeastern United States in summer. Dust concentrations vary considerably temporally and spatially. In a dust source region (Mali), concentrations range from background levels of 575 micrograms per cubic meter (mu/u g per m3) to 13,000 mu/u g per m3 when visibility degrades to a few meters (Gillies and others, 1996). In the Caribbean, concentrations of 200 to 600 mu/u g per m3 in the mid-Atlantic and Barbados (Prospero and others, 1981; Talbot and others, 1986), 3 to 20 mu/u g per m3 in the Caribbean (Prospero and Nees, 1986; Perry and others, 1997); and >100 mu/u g per m3 in the Virgin Islands (this dataset) have been reported during African dust conditions. Mean dust particle size decreases as the SAL traverses from West Africa to the Caribbean and Americas as a result of gravitational settling. Mean particle size reaching the Caribbean is <1 micrometer (mu/u m) (Perry and others, 1997), and even finer particles are carried into Central America, the Southeastern United States, and maritime Canada. Particles less than 2.5 mu/u m diameter (termed PM2.5) can be inhaled deeply into human lungs. A large body of literature has shown that increased PM2.5 concentrations are linked to increased cardiovascular/respiratory morbidity and mortality (for example, Dockery and others, 1993; Penn and others, 2005).

  4. Concentrations of polybrominated diphenyl ethers (PBDEs) in central air-conditioner filter dust and relevance of non-dietary exposure in occupational indoor environments in Greece.

    Science.gov (United States)

    Besis, Athanasios; Katsoyiannis, Athanasios; Botsaropoulou, Elisavet; Samara, Constantini

    2014-05-01

    Polybrominated Diphenyl Ethers (PBDEs) are ubiquitous in the indoor environment owing to their use in consumer products and various studies around the world have found higher concentrations indoors than outdoors. Central air conditioner (A/C) systems have been widely used in many workplaces, therefore, studying of PBDEs in central A/C filter dust is useful to better understand the occurrences and health implications of PBDEs in indoor environments. The present study examined the occurrence of PBDEs in central A/C filter dust collected from various workplaces (n = 20) in Thessaloniki, Greece. The sum concentrations of 21 target congeners (∑21PBDE) in A/C dust ranged between 84 and 4062 ng g(-1) with a median value of 1092 ng g(-1), while BDE-209 was found to be the most abundant BDE congener. The daily intake via dust ingestion of PBDEs estimated for the employees of the occupational settings ranged from 3 to 45 ng day(-1) (median 12 ng day(-1)). Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Experimental Method for Measuring Dust Load on Surfaces in Rooms

    DEFF Research Database (Denmark)

    Lengweiler, Philip; Nielsen, Peter V.; Moser, Alfred

    A new experimental setup to investigate the physical process of dust deposition and resuspension on and from surfaces is introduced. Dust deposition can reduce the airborne dust concentration considerably. As a basis for developing methods to eliminate dust-related problems in rooms, there is a n......A new experimental setup to investigate the physical process of dust deposition and resuspension on and from surfaces is introduced. Dust deposition can reduce the airborne dust concentration considerably. As a basis for developing methods to eliminate dust-related problems in rooms......, there is a need for better understanding of the mechanism of dust deposition and resuspension. With the presented experimental setup, the dust load on surfaces in a channel can be measured as a function of the environmental and surface conditions and the type of particles under controlled laboratory conditions....

  6. Galactic dust and extinction

    International Nuclear Information System (INIS)

    Lyngaa, G.

    1979-01-01

    The ratio R between visual extinction and colour excess, is slightly larger than 3 and does not vary much throughout our part of the Galaxy. The distribution of dust in the galactic plane shows, on the large scale, a gradient with higher colour excesses towards l=50 0 than towards l=230 0 . On the smaller scale, much of the dust responsible for extinction is situated in clouds which tend to group together. The correlation between positions of interstellar dust clouds and positions of spiral tracers seems rather poor in our Galaxy. However, concentrated dark clouds as well as extended regions of dust show an inclined distribution similar to the Gould belt of bright stars. (Auth.)

  7. Organophosphate esters and phthalate esters in human hair from rural and urban areas, Chongqing, China: Concentrations, composition profiles and sources in comparison to street dust.

    Science.gov (United States)

    He, Ming-Jing; Lu, Jun-Feng; Ma, Jing-Ye; Wang, Huan; Du, Xiao-Fan

    2018-06-01

    Human hair and street dust from rural and urban areas in Chongqing were collected to analyze Organophosphate esters (OPEs) and phthalate esters (PAEs). Concentrations of OPEs in urban hair were significantly higher than those in rural hair, whereas PAEs concentrations in rural hair were significantly higher than those in urban hair. Different composition patterns of OPEs were observed in rural and urban hair, where tris (2-chloroisopropyl) phosphate (TCIPP), tris (butyl) phosphate (TNBP) and triphenyl phosphate (TPHP) were the dominating analogues in rural hair, accounting for 62.1% of the OPEs burden, and tris (methylphenyl) phosphate (TMPP) exhibited a high contribution in urban hair, responsible for 51.3% of total OPEs, which differed from the composition profiles in corresponding street dust. Analogous composition patterns of PAEs were found in hair of both areas. Di-(2-ethylhexyl) phthalate (DEHP), dibutyl phthalate (DNBP), diisobutyl phthalate (DIBP) and diethyl phthalate (DEP) were the most abundant analogues in hair samples, while DEHP was the predominant analogue in dust samples. No clear tendency was obtained between the increasing ages and the concentrations of both compounds. Most OPEs and PAEs congeners showed significantly positive correlation with one another in rural hair. On the contrary, different correlation patterns were observed in urban hair for OPEs and PAEs, indicating multiple or additional sources existed in urban areas. Significant correlations of OPEs and PAEs were found between hair and corresponding street dust samples, but poor correlations of OPEs and PAEs were observed between rural hair and rural indoor dust, suggesting that street dust may be a predominant exogenous source for human exposure to OPEs and PAEs in this area. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Simulation of the mineral dust content over Western Africa from the event to the annual scale with the CHIMERE-DUST model

    Directory of Open Access Journals (Sweden)

    C. Schmechtig

    2011-07-01

    Full Text Available The chemistry and transport model CHIMERE-DUST have been used to simulate the mineral dust cycle over the Sahara in 2006. Surface measurements deployed during the AMMA field campaign allow to test the capability of the model to correctly reproduce the atmospheric dust load and surface concentrations from the daily to the seasonal time-scale. The simulated monthly mean Aerosol Optical Depths (AOD and surface concentrations are significantly correlated with the measured ones. The simulated daily concentrations and hourly AOD are in the same range of magnitude than the observed ones despite relatively high simulated dust emissions. The level of agreement between the simulations and the observations has been quantified at different time scales using statistical parameters classically used to evaluate air quality models. The capability of the model to reproduce the altitude of the dust transport was tested for two contrasted cases of low and high altitude transport. These results highlight the sensitivity of the simulations to the surface winds used as external forcing and the necessity to further constrain the dust mass budget at the regional scale.

  9. Feather bedding and childhood asthma associated with house dust mite sensitisation: a randomised controlled trial.

    Science.gov (United States)

    Glasgow, Nicholas J; Ponsonby, Anne-Louise; Kemp, Andrew; Tovey, Euan; van Asperen, Peter; McKay, Karen; Forbes, Samantha

    2011-06-01

    Observational studies report inverse associations between the use of feather upper bedding (pillow and/or quilt) and asthma symptoms but there is no randomised controlled trial (RCT) evidence assessing the role of feather upper bedding as a secondary prevention measure. To determine whether, among children not using feather upper bedding, a new feather pillow and feather quilt reduces asthma severity among house dust mite (HDM) sensitised children with asthma over a 1-year period compared with standard dust mite avoidance advice, and giving children a new mite-occlusive mattress cover. RCT. The Calvary Hospital in the Australian Capital Territory and the Children's Hospital at Westmead, Sydney, New South Wales. 197 children with HDM sensitisation and moderate to severe asthma. Intervention New upper bedding duck feather pillow and quilt and a mite-occlusive mattress cover (feather) versus standard care and a mite-occlusive mattress cover (standard). The proportion of children reporting four or more episodes of wheeze in the past year; an episode of speech-limiting wheeze; or one or more episodes of sleep disturbance caused by wheezing; and spirometry with challenge testing. Statistical analysis included multiple logistic and linear regression. No differences between groups were found for primary end points--frequent wheeze (OR 1.51, 95% CI 0.83 to 2.76, p=0.17), speech-limiting wheeze (OR 0.70, 95% CI 0.32 to 1.48, p=0.35), sleep disturbed because of wheezing (OR 1.17, 95% CI 0.64 to 2.13, p=0.61) or for any secondary end points. Secondary analyses indicated the intervention reduced the risk of sleep being disturbed because of wheezing and severe wheeze to a greater extent for children who slept supine. No differences in respiratory symptoms or lung function were observed 1 year after children with moderate-severe asthma and HDM sensitisation were given a mite-occlusive mattress cover and then received either feather upper bedding (pillow and quilt) or standard

  10. Investigation of indoor radon concentration in block houses in Omderman

    International Nuclear Information System (INIS)

    Ahmed, H. A. M.

    2010-12-01

    Radon is one of the naturally occurring radioactive elements in the environment as a member of the natural uranium decay. Exposure to radon in the home and workplace is one of the main risks of ionizing radiation thought to cause tens of thousands of deaths from lung cancer each year. In order to reduce this burden it is important that national authorities have methods and tools bases on solid scientific evidence and sound public health policy. The public needs to be aware of radon risks and the means to reduce and prevent these. This study presents of the studies dealing with the investigation of exposure from ionizing radiation. The radon levels in some selected type of building styles (Bricks Albulk) were investigated in Omderman city (public housing). The radon level in most of the houses found to range between 87.63 and 206 Bq/m 3 with average value of 127±23 Bq/m 3 . This is well lay within the allowable limit with average. The study indicates that building materials used does not add significant concentration of radon to indoor. It can be considered as safe type of building style from radiation protection point of view. (Author)

  11. Saharan dust levels in Greece and received inhalation doses

    Directory of Open Access Journals (Sweden)

    C. Mitsakou

    2008-12-01

    Full Text Available The desert of Sahara is one of the major sources of mineral dust on Earth, producing around 2×108 tons/yr. Under certain weather conditions, dust particles from Saharan desert get transported over the Mediterranean Sea and most of Europe. The limiting values set by the directive EC/30/1999 of European Union can easily be exceeded by the transport of desert dust particles in the south European Region and especially in urban areas, where there is also significant contribution from anthropogenic sources. In this study, the effects of dust transport on air quality in several Greek urban areas are quantified. PM10 concentration values from stationary monitoring stations are compared to dust concentrations for the 4-year period 2003–2006. The dust concentration values in the Greek areas were estimated by the SKIRON modelling system coupled with embedded algorithms describing the dust cycle. The mean annual dust contribution to daily-averaged PM10 concentration values was found to be around or even greater than 10% in the urban areas throughout the years examined. Natural dust transport may contribute by more than 20% to the annual number of exceedances – PM10 values greater than EU limits – depending on the specific monitoring location. In a second stage of the study, the inhaled lung dose received by the residents in various Greek locations is calculated. The particle deposition efficiency of mineral dust at the different parts of the human respiratory tract is determined by applying a lung dosimetry numerical model, which incorporates inhalation dynamics and aerosol physical processes. The inhalation dose from mineral dust particles was greater in the upper respiratory system (extrathoracic region and less significant in the lungs, especially in the sensitive alveolar region. However, in cases of dust episodes, the amounts of mineral dust deposited along the human lung are comparable to those

  12. Bio-processing of copper from combined smelter dust and flotation concentrate: A comparative study on the stirred tank and airlift reactors

    Energy Technology Data Exchange (ETDEWEB)

    Vakylabad, Ali Behrad, E-mail: alibehzad86@yahoo.co.uk [Department of Mining Engineering, Shahid Bahonar University, Kerman (Iran, Islamic Republic of); Engineers of Nano and Bio Advanced Sciences Company (ENBASCo.), ATIC, Mohaghegh University (Iran, Islamic Republic of); Schaffie, Mahin [Department of Chemical Engineering, Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Mineral Industries Research Centre (MIRC), Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Ranjbar, Mohammad [Department of Mining Engineering, Shahid Bahonar University, Kerman (Iran, Islamic Republic of); Mineral Industries Research Centre (MIRC), Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Manafi, Zahra [Sarcheshmeh Copper Complex, National Iranian Copper Industry Company (Iran, Islamic Republic of); Darezereshki, Esmaeel [Mineral Industries Research Centre (MIRC), Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of); Energy and Environmental Engineering Research Center (EERC), Shahid Bahonar University of Kerman, Kerman (Iran, Islamic Republic of)

    2012-11-30

    Highlights: Black-Right-Pointing-Pointer Flotation concentrate and smelter dust were sampled and combined. Black-Right-Pointing-Pointer Copper bioleaching from the combined was investigated. Black-Right-Pointing-Pointer Two bio-reactors were investigated and optimized: stirred and airlift. Black-Right-Pointing-Pointer STRs had better technical conditions and situations for bacterial leaching. - Abstract: To scrutinize the influence of the design and type of the bioreactors on the bioleaching efficiency, the bioleaching were evaluated in a batch airlift and a batch stirred tank bioreactors with mixed mesophilic and mixed moderately thermophilic bacteria. According to the results, maximum copper recoveries were achieved using the cultures in the stirred tank bioreactors. It is worth noting that the main phase of the flotation concentrate was chalcopyrite (as a primary sulphide), but the smelter dust mainly contained secondary copper sulphides such as Cu{sub 2}S, CuS, and Cu{sub 5}FeS{sub 4}.Under optimum conditions, copper dissolution from the combined flotation concentrate and smelter dust (as an environmental hazard) reached 94.50% in the STR, and 88.02% in the airlift reactor with moderately thermophilic, after 23 days. Also, copper extractions calculated for the bioleaching using mesophilic bacteria were 48.73% and 37.19% in the STR (stirred tank reactor) and the airlift bioreactor, respectively. In addition, the SEM/EDS, XRD, chemical, and mineralogical analyses and studies confirmed the above results.

  13. Bio-processing of copper from combined smelter dust and flotation concentrate: A comparative study on the stirred tank and airlift reactors

    International Nuclear Information System (INIS)

    Vakylabad, Ali Behrad; Schaffie, Mahin; Ranjbar, Mohammad; Manafi, Zahra; Darezereshki, Esmaeel

    2012-01-01

    Highlights: ► Flotation concentrate and smelter dust were sampled and combined. ► Copper bioleaching from the combined was investigated. ► Two bio-reactors were investigated and optimized: stirred and airlift. ► STRs had better technical conditions and situations for bacterial leaching. - Abstract: To scrutinize the influence of the design and type of the bioreactors on the bioleaching efficiency, the bioleaching were evaluated in a batch airlift and a batch stirred tank bioreactors with mixed mesophilic and mixed moderately thermophilic bacteria. According to the results, maximum copper recoveries were achieved using the cultures in the stirred tank bioreactors. It is worth noting that the main phase of the flotation concentrate was chalcopyrite (as a primary sulphide), but the smelter dust mainly contained secondary copper sulphides such as Cu 2 S, CuS, and Cu 5 FeS 4 .Under optimum conditions, copper dissolution from the combined flotation concentrate and smelter dust (as an environmental hazard) reached 94.50% in the STR, and 88.02% in the airlift reactor with moderately thermophilic, after 23 days. Also, copper extractions calculated for the bioleaching using mesophilic bacteria were 48.73% and 37.19% in the STR (stirred tank reactor) and the airlift bioreactor, respectively. In addition, the SEM/EDS, XRD, chemical, and mineralogical analyses and studies confirmed the above results.

  14. Characteristics of mineral dust impacting the Persian Gulf

    Science.gov (United States)

    Ahmady-Birgani, Hesam; McQueen, Kenneth G.; Mirnejad, Hassan

    2018-02-01

    It is generally assumed that severe dust events in western Iran could be responsible for elevated levels of toxic and radioactive elements in the region. Over a period of 5 months, from January 2012 to May 2012, dust particles in the size range PM10 (i.e. chemical compositions of dust and aerosol samples collected during the non-dusty periods and during two severe dust events. Results of ICP-MS analysis of components indicate that during dust events the concentrations of major elements such as Ca, Mg, Al and K increase relative to ambient conditions when Fe and trace elements such as Cu, Cr, Ni, Pb and Zn are in higher proportions. Toxic trace elements that are generally ascribed to human activities, including industrial and urban pollution, are thus proportionately more abundant in the dust under calm conditions than during dust events, when their concentration is diluted by more abundant mineral particles of quartz, calcite and clay. The variability of chemical species during two dust events, noted by tracking the dust plumes in satellite images, was also assessed and the results relate to two different source areas, namely northern Iraq and northwestern Syria.

  15. Vertical profiles of aerosol mass concentration derived by unmanned airborne in situ and remote sensing instruments during dust events

    Science.gov (United States)

    Mamali, Dimitra; Marinou, Eleni; Sciare, Jean; Pikridas, Michael; Kokkalis, Panagiotis; Kottas, Michael; Binietoglou, Ioannis; Tsekeri, Alexandra; Keleshis, Christos; Engelmann, Ronny; Baars, Holger; Ansmann, Albert; Amiridis, Vassilis; Russchenberg, Herman; Biskos, George

    2018-05-01

    In situ measurements using unmanned aerial vehicles (UAVs) and remote sensing observations can independently provide dense vertically resolved measurements of atmospheric aerosols, information which is strongly required in climate models. In both cases, inverting the recorded signals to useful information requires assumptions and constraints, and this can make the comparison of the results difficult. Here we compare, for the first time, vertical profiles of the aerosol mass concentration derived from light detection and ranging (lidar) observations and in situ measurements using an optical particle counter on board a UAV during moderate and weak Saharan dust episodes. Agreement between the two measurement methods was within experimental uncertainty for the coarse mode (i.e. particles having radii > 0.5 µm), where the properties of dust particles can be assumed with good accuracy. This result proves that the two techniques can be used interchangeably for determining the vertical profiles of aerosol concentrations, bringing them a step closer towards their systematic exploitation in climate models.

  16. Raapzaadeiwitconcentraat en erwteneiwitconcentraat in biologisch biggenvoer = Canola protein concentrate and pea protein concentratrate in diets for organically housed piglets

    NARCIS (Netherlands)

    Peet-Schwering, van der C.M.C.; Binnendijk, G.P.; Diepen, van J.T.M.

    2011-01-01

    At the Experimental Farm Raalte it was investigated whether canola protein concentrate and pea protein concentrate are suitable protein-rich feedstuffs for organically housed piglets. It is concluded that both protein concentrates are suitable protein-rich feedstuffs for piglets. Feed intake and

  17. Air Pollution Modelling to Predict Maximum Ground Level Concentration for Dust from a Palm Oil Mill Stack

    Directory of Open Access Journals (Sweden)

    Regina A. A.

    2010-12-01

    Full Text Available The study is to model emission from a stack to estimate ground level concentration from a palm oil mill. The case study is a mill located in Kuala Langat, Selangor. Emission source is from boilers stacks. The exercise determines the estimate the ground level concentrations for dust to the surrounding areas through the utilization of modelling software. The surround area is relatively flat, an industrial area surrounded by factories and with palm oil plantations in the outskirts. The model utilized in the study was to gauge the worst-case scenario. Ambient air concentrations were garnered calculate the increase to localized conditions. Keywords: emission, modelling, palm oil mill, particulate, POME

  18. Association of pediatric asthma severity with exposure to common household dust allergens

    International Nuclear Information System (INIS)

    Gent, Janneane F.; Belanger, Kathleen; Triche, Elizabeth W.; Bracken, Michael B.; Beckett, William S.; Leaderer, Brian P.

    2009-01-01

    Background: Reducing exposure to household dust inhalant allergens has been proposed as one strategy to reduce asthma. Objective: To examine the dose-response relationships and health impact of five common household dust allergens on disease severity, quantified using both symptom frequency and medication use, in atopic and non-atopic asthmatic children. Methods: Asthmatic children (N=300) aged 4-12 years were followed for 1 year. Household dust samples from two indoor locations were analyzed for allergens including dust mite (Der p 1, Der f 1), cat (Fel d 1), dog (Can f 1), cockroach (Bla g 1). Daily symptoms and medication use were collected in monthly telephone interviews. Annual disease severity was examined in models including allergens, specific IgE sensitivity and adjusted for age, gender, atopy, ethnicity, and mother's education. Results: Der p 1 house dust mite allergen concentration of 2.0 μg/g or more from the main room and the child's bed was related to increased asthma severity independent of allergic status (respectively, OR 2.93, 95% CI 1.37, 6.30 for 2.0-10.0 μg/g and OR 2.55 95% CI 1.13, 5.73 for ≥10.0 μg/g). Higher pet allergen levels were associated with greater asthma severity, but only for those sensitized (cat OR 2.41 95% CI 1.19, 4.89; dog OR 2.06 95% CI 1.01, 4.22). Conclusion: Higher levels of Der p 1 and pet allergens were associated with asthma severity, but Der p 1 remained an independent risk factor after accounting for pet allergens and regardless of Der p 1 specific IgE status.

  19. Association of pediatric asthma severity with exposure to common household dust allergens

    Energy Technology Data Exchange (ETDEWEB)

    Gent, Janneane F., E-mail: janneane.gent@yale.edu [Yale Center for Perinatal, Pediatric and Environmental Epidemiology, Department of Epidemiology and Public Health, Yale University School of Medicine, One Church Street, 6th Floor, New Haven, CT 06510 (United States); Belanger, Kathleen [Yale Center for Perinatal, Pediatric and Environmental Epidemiology, Department of Epidemiology and Public Health, Yale University School of Medicine, One Church Street, 6th Floor, New Haven, CT 06510 (United States); Triche, Elizabeth W. [Brown University, Department of Community Health/Epidemiology, Providence, RI (United States); Bracken, Michael B. [Yale Center for Perinatal, Pediatric and Environmental Epidemiology, Department of Epidemiology and Public Health, Yale University School of Medicine, One Church Street, 6th Floor, New Haven, CT 06510 (United States); Beckett, William S. [Mount Auburn Hospital, Department of Internal Medicine, Cambridge, MA (United States); Leaderer, Brian P. [Yale Center for Perinatal, Pediatric and Environmental Epidemiology, Department of Epidemiology and Public Health, Yale University School of Medicine, One Church Street, 6th Floor, New Haven, CT 06510 (United States)

    2009-08-15

    Background: Reducing exposure to household dust inhalant allergens has been proposed as one strategy to reduce asthma. Objective: To examine the dose-response relationships and health impact of five common household dust allergens on disease severity, quantified using both symptom frequency and medication use, in atopic and non-atopic asthmatic children. Methods: Asthmatic children (N=300) aged 4-12 years were followed for 1 year. Household dust samples from two indoor locations were analyzed for allergens including dust mite (Der p 1, Der f 1), cat (Fel d 1), dog (Can f 1), cockroach (Bla g 1). Daily symptoms and medication use were collected in monthly telephone interviews. Annual disease severity was examined in models including allergens, specific IgE sensitivity and adjusted for age, gender, atopy, ethnicity, and mother's education. Results: Der p 1 house dust mite allergen concentration of 2.0 {mu}g/g or more from the main room and the child's bed was related to increased asthma severity independent of allergic status (respectively, OR 2.93, 95% CI 1.37, 6.30 for 2.0-10.0 {mu}g/g and OR 2.55 95% CI 1.13, 5.73 for {>=}10.0 {mu}g/g). Higher pet allergen levels were associated with greater asthma severity, but only for those sensitized (cat OR 2.41 95% CI 1.19, 4.89; dog OR 2.06 95% CI 1.01, 4.22). Conclusion: Higher levels of Der p 1 and pet allergens were associated with asthma severity, but Der p 1 remained an independent risk factor after accounting for pet allergens and regardless of Der p 1 specific IgE status.

  20. Immunoinformatics and Similarity Analysis of House Dust Mite Tropomyosin

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Ranjbar

    2015-10-01

    Full Text Available Background: Dermatophagoides farinae and Dermatophagoides pteronyssinus are house dust mites (HDM that they cause severe asthma and allergic symptoms. Tropomyosin protein plays an important role in mentioned immune and allergic reactions to HDMs. Here, tropomyosin protein from Dermatophagoides spp. was comprehensively screened in silico for its allergenicity, antigenicity and similarity/conservation.Materials and Methods: The amino acid sequences of D. farinae tropomyosin, D. pteronyssinus and other mites were retrieved. We included alignments and evaluated conserved/ variable regions along sequences, constructed their phylogenetic tree and estimated overall mean distances. Then, followed by with prediction of linear B-cell epitope based on different approaches, and besides in-silico evaluation of IgE epitopes allergenicity (by SVMc, IgE epitope, ARPs BLAST, MAST and hybrid method. Finally, comparative analysis of results by different approaches was made.Results: Alignment results revealed near complete identity between D. farina and D. pteronyssinus members, and also there was close similarity among Dermatophagoides spp. Most of the variations among mites' tropomyosin were approximately located at amino acids 23 to 80, 108 to 120, 142 to 153 and 220 to 230. Topology of tree showed close relationships among mites in tropomyosin protein sequence, although their sequences in D. farina, D. pteronyssinus and Psoroptes ovis are more similar to each other and clustered. Dermanyssus gallinae (AC: Q2WBI0 has less relationship to other mites, being located in a separate branch. Hydrophilicity and flexibility plots revealed that many parts of this protein have potential to be hydrophilic and flexible. Surface accessibility represented 7 different epitopes. Beta-turns in this protein are with high probability in the middle part and its two terminals. Kolaskar and Tongaonkar method analysis represented 11 immunogenic epitopes between amino acids 7-16. From

  1. Ground level and Lidar monitoring of volcanic dust and dust from Patagonia

    Science.gov (United States)

    Otero, L. A.; Losno, R.; Salvador, J. O.; Journet, E.; Qu, Z.; Triquet, S.; Monna, F.; Balkanski, Y.; Bulnes, D.; Ristori, P. R.; Quel, E. J.

    2013-05-01

    A combined approach including ground level aerosol sampling, lidar and sunphotometer measurements is used to monitor suspended particles in the atmosphere at several sites in Patagonia. Motivated by the Puyehue volcanic eruption in June 2011 two aerosol monitoring stations with several passive and active instruments were installed in Bariloche and Comodoro Rivadavia. The main goal which is to monitor ground lifted and transported ashes and dust involving danger to civil aviation, is achieved by measuring continuously aerosol concentration at ground level and aerosol vertical distribution using lidar. In addition, starting from December 2011, continuous series of weekly accumulated aerosol concentrations at Rio Gallegos are being measured to study the impact of Patagonian dust over the open ocean on phytoplankton primary productivity and CO2 removal. These measurements are going to be coupled with LIDAR monitoring and a dust optical response models to test if aerosol extrapolation can be done from the ground to the top of the layer. Laboratory chemical analysis of the aerosols will include elemental composition, solubilisation kinetic and mineralogical determination. Expected deliverables for this study is the estimation of the amount of dust exported from Patagonia towards the South Atlantic, its chemical properties, including bioavailability simulation, from model and comparison to experimental measurements.

  2. 'Nuisance Dust' - a Case for Recalibration?

    Science.gov (United States)

    Datson, Hugh; Marker, Brian

    2013-04-01

    This paper considers the case for a review and recalibration of limit values and acceptability criteria for 'nuisance dust', a widely encountered but poorly defined and regulated aspect of particulate matter pollution. Specific dust fractions such as PM10 and asbestiforms are well characterised and have limit values enshrined in legislation. National, and international, limit values for acceptable concentrations of PM10 and other fractions of particulate matter have been defined and agreed. In the United Kingdom (UK), these apply to both public and workplace exposures. By contrast, there is no standard definition or universal criteria against which acceptable levels for 'nuisance dust' can be assessed. This has implications for land-use planning and resource utilisation. Without meaningful limit values, inappropriate development might take place too near to residential dwellings or land containing economically important mineral resources may be effectively sterilised. Furthermore, the expression 'nuisance dust' is unhelpful in that 'nuisance' has a specific meaning in environmental law whilst 'nuisance dust' is often taken to mean 'generally visible particulate matter'. As such, it is associated with the social and broader environmental impacts of particulate matter. PM10 concentrations are usually expressed as a mass concentration over time. These can be determined using a range of techniques. While results from different instruments are generally comparable, data obtained from alternative methods for measuring 'nuisance dust' are rarely interchangeable. In the UK, many of the methods typically used are derived from approaches developed under the HMIP (Her Majesty's Inspectorate of Pollution) regime in the 1960s onwards. Typical methods for 'nuisance dust' sampling focus on measurement of dust mass (from the weight of dust collected in an open container over time) or dust soiling (from loss of reflectance and or obscuration of a surface discoloured by dust over

  3. Air exchanges and indoor carbon dioxide concentration in Australian pig buildings: Effect of housing and management factors

    DEFF Research Database (Denmark)

    Banhazi, T. M.; Stott, P.; Rutley, D.

    2011-01-01

    There has been a growing interest in improving air quality within livestock buildings. However, the influence of housing and management factors on air exchange rates and indoor gas concentrations is not well understood. The aim of this study was to determine the effects of housing and management...... production, although these buildings may not always provide an optimal environment for pig production. (C) 2011 IAgrE. Published by Elsevier Ltd. All rights reserved....

  4. Radon in Syrian houses

    International Nuclear Information System (INIS)

    Othman, I.; Hushari, M.; Raja, G.; Alsawaf, A.

    1996-01-01

    A nationwide investigation of radon levels in Syrian houses was carried out during the period 1991-1993. Passive radon diffusion dosemeters using polycarbonate detectors were distributed in houses all over Syria. Detectors were subjected to electrochemical etching to reveal latent tracks of alpha particles. The mean radon concentration in Syrian houses was found to be 45 Bq m -3 with some values several times higher. This investigation indicated that there were a few houses in Syria that require remedial action. Most houses that have high levels of radon were found in the southern area, especially in the Damascus governorate. The study also indicated that radon concentrations were higher in old houses built from mud with no tiling. (author)

  5. Investigation of indoor radon concentration in block houses in Omderman

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, H A. M. [Atomic Energy Council, Sudan Academy of Sciences (SAS), Khartoum (Sudan)

    2010-12-15

    Radon is one of the naturally occurring radioactive elements in the environment as a member of the natural uranium decay. Exposure to radon in the home and workplace is one of the main risks of ionizing radiation thought to cause tens of thousands of deaths from lung cancer each year. In order to reduce this burden it is important that national authorities have methods and tools bases on solid scientific evidence and sound public health policy. The public needs to be aware of radon risks and the means to reduce and prevent these. This study presents of the studies dealing with the investigation of exposure from ionizing radiation. The radon levels in some selected type of building styles (Bricks Albulk) were investigated in Omderman city (public housing). The radon level in most of the houses found to range between 87.63 and 206 Bq/m{sup 3} with average value of 127{+-}23 Bq/m{sup 3}. This is well lay within the allowable limit with average. The study indicates that building materials used does not add significant concentration of radon to indoor. It can be considered as safe type of building style from radiation protection point of view. (Author)

  6. Radioisotope dust pollution monitor

    International Nuclear Information System (INIS)

    Szepke, R.; Harasimczuk, J.; Dobrowiecki, J.

    1990-01-01

    Measuring principles and specification of two dust monitors: station-type AMIZ and portable-type PIK-10 for ambient air pollution are presented. The first one, a fully automatic instrument is destined for permanent monitoring of air pollution in preset sampling time from .25 to 24 hours. The second one was developed as a portable working model. Both instruments display their results in digital form in dust concentration units. (author)

  7. Long-term airborne contamination studied by attic dust in an industrial area: Ajka, Hungary

    Science.gov (United States)

    Völgyesi, P.; Jordan, G.; Szabo, Cs.

    2012-04-01

    Heavy industrial activities such as mining, metal industry, coal fired power plants have produced large amount of by-products and wide-spread pollution, particularly in the period of centrally dictated economy after WWII, in Hungary. Several studies suggest that significant amount of these pollutants have been deposited in the urban environment. Nowadays, more than half of the world's population is living in urban areas and people spend almost 80% of their lives indoors in developed countries increasing human health risk due to contamination present in urban dwellings. Attic dust sampling was applied to determine the long-term airborne contamination load in the industrial town of Ajka (Hungary). There has been a high industrial activity in Ajka since the end of the 19th century. In addition to aluminum and alumina industry, coal mining, coal fired power plant and glass industry sites, generated numerous waste heaps which act as multi-contamination sources in the area. In October 2010 the Ajka red mud tailings pond failed and caused an accidental regional contamination of international significance. The major objective of this research was to study and map the spatial distribution of heavy metal contamination in airborne attic dust samples. At 27 sampling sites 30 attic dust samples were collected. Sampling strategy followed a grid-based stratified random sampling design. In each cell a house for attic dust sample collection was selected that was located the closest to a randomly generated point in the grid cell. The project area covers a 8x8 grid of 1x1 km cells with a total area of 64 km2. In order to represent long-term industrial pollution, houses with attics kept intact for at least 30-40 years were selected for sampling. Sampling included the collection of background samples remotely placed from the industrialized urban area. The concentration of the major and toxic elements (Al, Ca, Fe, K, Mg, Mn, Na, P, S, and As, Ba, Cd, Co, Cr, Cu, Li, Mo, Ni, Pb, Se, Sn

  8. Allergic Responses Induced by a Fungal Biopesticide Metarhizium anisopliae and House Dust Mite Are Compared in a Mouse Model

    Directory of Open Access Journals (Sweden)

    Marsha D. W. Ward

    2011-01-01

    Full Text Available Biopesticides can be effective in controlling their target pest. However, research regarding allergenicity and asthma development is limited. We compared the ability of fungal biopesticide Metarhizium anisopliae (MACA and house dust mite (HDM extracts to induce allergic responses in BALB/c mice. The extracts were administered by intratracheal aspiration at doubling doses (2.5–80 g protein 4X over a four-week period. Three days after the last exposure, serum and bronchoalveolar lavage fluid (BALF were collected. The extracts' relative allergenicity was evaluated based on response robustness (lowest significant dose response compared to control (0 g. MACA induced a more robust serum total IgE response than HDM. However, in the antigen-specific IgE assay, a similar dose of both MACA and HDM was required to achieve the same response level. Our data suggest a threshold dose of MACA for allergy induction and that M. anisopliae may be similar to HDM in allergy induction potential.

  9. Aerosol-ozone correlations during dust transport episodes

    Directory of Open Access Journals (Sweden)

    P. Bonasoni

    2004-01-01

    Full Text Available Its location in the Mediterranean region and its physical characteristics render Mt. Cimone (44°11′ N, 10°42′ E, the highest peak of the Italian northern Apennines (2165 m asl, particularly suitable to study the transport of air masses from the north African desert area to Europe. During these northward transports 12 dust events were registered in measurements of the aerosol concentration at the station during the period June–December 2000, allowing the study of the impact of mineral dust transports on free tropospheric ozone concentrations, which were also measured at Mt. Cimone. Three-dimensional backward trajectories were used to determine the air mass origin, while TOMS Aerosol Index data for the Mt. Cimone area were used to confirm the presence of absorbing aerosol over the measurement site. A trajectory statistical analysis allowed identifying the main source areas of ozone and aerosols. The analysis of these back trajectories showed that central Europe and north and central Italy are the major pollution source areas for ozone and fine aerosol, whereas the north African desert regions were the most important source areas for coarse aerosol and low ozone concentrations. During dust events, the Mt. Cimone mean volume concentration for coarse particles was 6.18 µm3/cm3 compared to 0.63 µm3/cm3 in dust-free conditions, while the ozone concentrations were 4% to 21% lower than the monthly mean background values. Our observations show that surface ozone concentrations were lower than the background values in air masses coming from north Africa, and when these air masses were also rich in coarse particles, the lowest ozone values were registered. Moreover, preliminary results on the possible impact of the dust events on PM10 and ozone values measured in Italian urban and rural areas showed that during the greater number of the considered dust events, significant PM10 increases and ozone decreases have occurred in the Po valley.

  10. Prevalencia de la sensibilización a tres ácaros domésticos en la población infantil alérgica de un consultorio médico Prevalence of sensitization to three house dust mites in the allergic infantile population of a family physician's office

    Directory of Open Access Journals (Sweden)

    Mayda González León

    2005-04-01

    Full Text Available Se realizó un estudio con el objetivo de investigar si la sensibilización a estos ácaros ( Dermatophagoides pteronyssinus [ Dp ], Dermatophagoides siboney [ Ds ] y Blomia tropicalis [ Bt ] constituye un problema de salud en nuestra población infantil, pues el estudio de los problemas alérgicos ha identificado a los ácaros domésticos como los principales agentes causales de asma y otras afecciones. Se seleccionaron 32 niños alérgicos de nuestro consultorio que se clasificaron según su grado de exposición al polvo doméstico. A todos se les realizó la prueba por punción cutánea en el brazo derecho, y se utilizaron 3 extractos alergénicos estandarizados Valergen Ò ( Blomia tropicalis, Dermatophagoides siboney y Dermatophagoides pteronyssinus de producción nacional (BIOCEN. La prevalencia de la sensibilización fue mayor de forma significativa (pA study was conducted aimed at investigating if the sensitization to these dust mites (Dermatophagoides pteronyssinus [Dp], Dermatophagoides siboney [Ds] and Blomia tropicalis [Bt] is a health problem in our infantile population, since the study of the allergic problems has identified the house dust mites as the main agents causing asthma and other affections. 32 allergic children of our office were selected and classified according to their degree of exposure to house dust. All of them underwent the skin test in the right arm. 3 standardized allergenic extracts ValergenÒ (Blomia tropicalis, Dermatophagoides siboney y Dermatophagoides pteronyssinus of national production (BIOCEN were used. The prevalence of sensitization was significantly higher (p<0.05 for all the dust mites in patients with a greater exposure to house dust compared with those with lower exposure to it. A higher sensitization was attained for the dust mites of the genus Dermatophagoides. The extract of Dp produced a wheal with a mean size greater than the one caused by other products.

  11. [The epidemiological validation of the MPEL for grain dust in the atmosphere].

    Science.gov (United States)

    Pinigin, M A; Cherepov, E M; Safiulin, A A; Petrova, I V; Mukhambetova, L Kh; Osipova, E M; Veselov, A P

    1998-01-01

    The use of calculating and gravimetric methods for examining the grain dust pollution of the ambient air at the site of an elevator determined the maximum single, mean daily, and mean annual concentrations at different distances from the source of dust emission. The mean ratio of these concentrations was 12.1:4.3:1, respectively. The calculated concentration-effect and concentration-time relationships provided evidence for the maximum single, mean daily, and mean annual allowable concentrations for grain dust in the ambient air.

  12. Housing conditions and respiratory health in a Boston public housing community.

    Science.gov (United States)

    Brugge, D; Rice, P W; Terry, P; Howard, L; Best, J

    2001-01-01

    To determine frequency of and possible associations between environmental housing factors and self-reported respiratory symptoms in public housing. We used a community-participatory method in which trained residents conducted in-person interviews with a random sample of 53 households in one housing development in Boston, Massachusetts. Environmental factors suspected of affecting respiratory health that were reported by more than 30 percent of respondents included: Moisture (43 percent), mold (43 percent), cracks in walls, floors and ceilings (49 percent), sewage leaks (33 percent), unexplained odor (35 percent), use of air fresheners (91 percent), use of gas ovens for heating (38 percent), no vent for the oven (74 percent), stuffy air (66 percent), overheating at least part of the winter (73 percent), cockroaches (70 percent), rodents (40 percent), pets (39 percent), frequent renovations (40 percent), repeated requests for repairs (52 percent), dust from construction (45 percent), use of more than three hazardous household products (32 percent), vehicle traffic nearby (81 percent), and smoking in the household (57 percent). Forty percent of respondents reported having asthma. Respondents also reported that 56 percent of their children had asthma. Forty percent of respondents reported wheeze and 48 percent reported coughing or sneezing episodes in the preceding month. We found the following positive statistically significant associations, adjusted for age, sex, Black or Hispanic origin, and years lived in public housing: wheeze with moisture problems (OR = 4.8; CI = 1.2, 19.3), sewage leaks (OR = 6.3; CI = 1.3, 30.3), odor (OR = 7.5; CI = 1 .4, 39.0), cracks in walls,floors and ceilings (OR = 8.6; CI 1.9, 38.0), and frequency of renovations (OR = 9.8; CI = 1.8, 54.4); cough with moisture problems (OR = 5.3; CI = 1.3, 20.8), stuffy air (OR = 4.4; CI = 1.2, 16.7), cockroaches (OR = 5.4; CI = 1.2, 24.2), smoking (OR = 5.0; CI = 1.2, 20.5), odor (OR = 10.9; CI = 2

  13. Short-term variability of mineral dust, metals and carbon emission from road dust resuspension

    Science.gov (United States)

    Amato, Fulvio; Schaap, Martijn; Denier van der Gon, Hugo A. C.; Pandolfi, Marco; Alastuey, Andrés; Keuken, Menno; Querol, Xavier

    2013-08-01

    Particulate matter (PM) pollution in cities has severe impact on morbidity and mortality of their population. In these cities, road dust resuspension contributes largely to PM and airborne heavy metals concentrations. However, the short-term variation of emission through resuspension is not well described in the air quality models, hampering a reliable description of air pollution and related health effects. In this study we experimentally show that the emission strength of resuspension varies widely among road dust components/sources. Our results offer the first experimental evidence of different emission rates for mineral dust, heavy metals and carbon fractions due to traffic-induced resuspension. Also, the same component (or source) recovers differently in a road in Barcelona (Spain) and a road in Utrecht (The Netherlands). This finding has important implications on atmospheric pollution modelling, mostly for mineral dust, heavy metals and carbon species. After rain events, recoveries were generally faster in Barcelona rather than in Utrecht. The largest difference was found for the mineral dust (Al, Si, Ca). Tyre wear particles (organic carbon and zinc) recovered faster than other road dust particles in both cities. The source apportionment of road dust mass provides useful information for air quality management.

  14. Saharan Dust Event Impacts on Cloud Formation and Radiation over Western Europe

    Science.gov (United States)

    Bangert, M.; Nenes, A.; Vogel, B.; Vogel, H.; Barahona, D.; Karydis, V. A.; Kumar, P.; Kottmeier, C.; Blahak, U.

    2013-01-01

    We investigated the impact of mineral dust particles on clouds, radiation and atmospheric state during a strong Saharan dust event over Europe in May 2008, applying a comprehensive online-coupled regional model framework that explicitly treats particle-microphysics and chemical composition. Sophisticated parameterizations for aerosol activation and ice nucleation, together with two-moment cloud microphysics are used to calculate the interaction of the different particles with clouds depending on their physical and chemical properties. The impact of dust on cloud droplet number concentration was found to be low, with just a slight increase in cloud droplet number concentration for both uncoated and coated dust. For temperatures lower than the level of homogeneous freezing, no significant impact of dust on the number and mass concentration of ice crystals was found, though the concentration of frozen dust particles reached up to 100 l-1 during the ice nucleation events. Mineral dust particles were found to have the largest impact on clouds in a temperature range between freezing level and the level of homogeneous freezing, where they determined the number concentration of ice crystals due to efficient heterogeneous freezing of the dust particles and modified the glaciation of mixed phase clouds. Our simulations show that during the dust events, ice crystals concentrations were increased twofold in this temperature range (compared to if dust interactions are neglected). This had a significant impact on the cloud optical properties, causing a reduction in the incoming short-wave radiation at the surface up to -75Wm-2. Including the direct interaction of dust with radiation caused an additional reduction in the incoming short-wave radiation by 40 to 80Wm-2, and the incoming long-wave radiation at the surface was increased significantly in the order of +10Wm-2. The strong radiative forcings associated with dust caused a reduction in surface temperature in the order of -0

  15. Characterization of wood dust emission from hand-held woodworking machines.

    Science.gov (United States)

    Keller, F-X; Chata, F

    2018-01-01

    This article focuses on the prevention of exposure to wood dust when operating electrical hand-held sawing and sanding machines. A laboratory methodology was developed to measure the dust concentration around machines during operating processes. The main objective was to characterize circular saws and sanders, with the aim of classifying the different power tools tested in terms of dust emission (high dust emitter vs. low dust emitter). A test set-up was developed and is described and a measurement methodology was determined for each of the two operations studied. The robustness of the experimental results is discussed and shows good tendencies. The impact of air-flow extraction rate was assessed and the pressure loss of the system for each machine established. For the circular saws, three machines over the nine tested could be classified in the low dust emitter group. Their mean concentration values measured are between 0.64 and 0.98 mg/m 3 for the low dust emitter group and from 2.55 and 4.37 mg/m 3 for the high dust emitter group. From concentration measurements, a machine classification is possible-one for sanding machines and one for sawing machines-and a ratio from 1-7 is obtained when comparing the results. This classification will be helpful when a choice of high performance power tools, in terms of dust emission, must be made by professionals.

  16. On the Role of Dust in the Universe

    Science.gov (United States)

    Martin, P. G.

    2004-05-01

    This article is a personal discourse on the various aspects of dust in the universe, its so-called role. My conclusion is that dust does make a difference. It directly alters the way we view the universe. It also changes the nature of the universe that we see. Finally, it is woven into the big picture of our own place in the universe and our understanding and responses. In arriving at this conclusion I explore a range of topics: the curse of extinction, dust as a photon converter, diversity, Galactic ecology, and a cosmic bawdy house. I also reflect on dust and (in)humanity. I argue that we must advance the post-Copernican enlightenment, so that a coherent understanding of our place in the universe, the big picture, becomes widely held, to provide a basis for improving life here and now, bringing humans into harmony with one another, other living fauna and flora, and the shared environment. Countering pernicious trends to the contrary will require a social revolution to accompany the scientific, through ``ideas transfer.'' This is much more challenging than propagating technology. Astronomers, particularly those versed in the beauties and multiple dimensions of dust in the universe, have an opportunity to participate, indeed to intervene. Since ``dust is us,'' this too is a role of dust in the universe, arguably the most profound if it is accepted that continued human existence has any importance.

  17. Quality of life improvement after a three-year course of sublingual immunotherapy in patients with house dust mite and grass pollen induced allergic rhinitis: results from real-life.

    Science.gov (United States)

    Novakova, Silviya Mihaylova; Staevska, Maria Toncheva; Novakova, Plamena Ivanova; Yoncheva, Manuela Dimitrova; Bratoycheva, Maria Stoykova; Musurlieva, Nina Mihaylova; Tzekov, Valeri Dimitrov; Nicolov, Dimitar Georgiev

    2017-09-29

    Along with its high prevalence, the burden of allergic rhinitis rests upon the serious impact on quality of life of patients. Allergic rhinitis is associated with impairments in daily activities, work and school performance, and practical problems. Patients suffer from sleep disorders and emotional problems. Тhe advantages of sublingual immunotherapy on quality of life have only recently begun to emerge. The objective of this prospective real-life study was to evaluate the effect of a three-year course of sublingual immunotherapy with house dust mite (HDM) and grass pollen extracts on quality of life in adults with allergic rhinitis. A total number of 191 adult patients [105 (54,979%) men; mean age 27.3 years (SD-6.14)] with moderate to severe allergic rhinitis and clinically relevant sensitization to house dust mites or grass pollen were prospectively evaluated in the course of management of their disease. Health-related quality of life was assessed by Rhinoconjunctivitis Quality of Life Questionnaire at baseline and after three-year course of sublingual immunotherapy. The mean overall Qol score assessed at baseline and at the end of the third year of treatment decreased significantly in patients treated with HDM extract (from 2.95 to 0.76) as well as with Grass pollen extract (from 2.83 to 1.22) (р life provided evidence that a three-year course of SLIT with HDM extract as well as with grass pollen extract significantly increased QoL in patients with allergic rhinitis.

  18. House dust mite induces expression of intercellular adhesion molecule-1 in EoL-1 human eosinophilic leukemic cells.

    Science.gov (United States)

    Kwon, Byoung Chul; Sohn, Myung Hyun; Kim, Kyung Won; Kim, Eun Soo; Kim, Kyu-Earn; Shin, Myeong Heon

    2007-10-01

    The house dust mite (HDM) is considered to be the most common indoor allergen associated with bronchial asthma. In this study, we investigated whether crude extract of the HDM Dermatophagoides farinae could activate human eosinophilic leukemic cells (EoL-1) to induce upregulation of cell-surface adhesion molecules. When EoL-1 cells were incubated with D. farinae extract, expression of intercellular adhesion molecule-1 (ICAM-1) significantly increased on the cell surfaces compared to cells incubated with medium alone. In contrast, surface expression of CD11b and CD49d in EoL-1 cells was not affected by D. farinae extract. In addition, pretreatment of cells with NF-kappaB inhibitor (MG-132) or JNK inhibitor (SP600125) significantly inhibited ICAM-1 expression promoted by HDM extract. However, neither p38 MAP kinase inhibitor nor MEK inhibitor prevented HDM-induced ICAM-1 expression in EoL-1 cells. These results suggest that crude extract of D. farinae induces ICAM-1 expression in EoL-1 cells through signaling pathways involving both NF-kappaB and JNK.

  19. Effect of freezing, hot tumble drying and washing with eucalyptus oil on house dust mites in soft toys.

    Science.gov (United States)

    Chang, Chin-Fu; Wu, Francis Fu-Sheng; Chen, Chi-Ying; Crane, Julian; Siebers, Rob

    2011-09-01

    Soft toys are a major source of house dust mites (HDM) and HDM allergens, and sleeping with soft toys is a significant risk factor for HDM sensitization. We studied three techniques to eliminate HDM from soft toys, namely freezing, hot tumble drying and washing with eucalyptus oil. Thirty-six toys (12 in each treatment group) were enumerated for live HDM by the heat escape method before and after freezing overnight, hot tumble drying for 1 h and washing in 0.2% to 0.4% eucalyptus oil. Freezing, hot tumble drying and washing with eucalyptus oil resulted in significant reductions in live HDM, an average reduction of 95.1%, 89.1% and 95.1%, respectively. Additionally, washing with eucalyptus oil resulted in a significant reduction in HDM allergens as well from a geometric mean of 9.12 μg/g to 0.37 μg/g (p = 0.033). These three HDM elimination techniques give parents of infants effective and acceptable methods of limiting HDM exposure. © 2011 John Wiley & Sons A/S.

  20. Bee Venom Phospholipase A2 Alleviate House Dust Mite-Induced Atopic Dermatitis-Like Skin Lesions by the CD206 Mannose Receptor.

    Science.gov (United States)

    Shin, Dasom; Choi, Won; Bae, Hyunsu

    2018-04-02

    Atopic dermatitis (AD) is a chronic inflammatory skin disease characterized by highly pruritic, erythematous, and eczematous skin plaques. We previously reported that phospholipase A2 (PLA2) derived from bee venom alleviates AD-like skin lesions induced by 2,4-dinitrochlorobenzene (DNCB) and house dust mite extract ( Dermatophagoides farinae extract, DFE) in a murine model. However, the underlying mechanisms of PLA2 action in actopic dermatitis remain unclear. In this study, we showed that PLA2 treatment inhibited epidermal thickness, serum immunoglobulin E (IgE) and cytokine levels, macrophage and mast cell infiltration in the ear of an AD model induced by DFE and DNCB. In contrast, these effects were abrogated in CD206 mannose receptor-deficient mice exposed to DFE and DNCB in the ear. These data suggest that bvPLA2 alleviates atopic skin inflammation via interaction with CD206.

  1. Pantoea agglomerans: a mysterious bacterium of evil and good. Part II--Deleterious effects: Dust-borne endotoxins and allergens--focus on grain dust, other agricultural dusts and wood dust.

    Science.gov (United States)

    Dutkiewicz, Jacek; Mackiewicz, Barbara; Lemieszek, Marta Kinga; Golec, Marcin; Skórska, Czesława; Góra-Florek, Anna; Milanowski, Janusz

    2016-01-01

    Pantoea agglomerans, a Gram-negative bacterium developing in a variety of plants as epiphyte or endophyte is particularly common in grain and grain dust, and has been identified by an interdisciplinary group from Lublin, eastern Poland, as a causative agent of work-related diseases associated with exposure to grain dust and other agricultural dusts. The concentration of P. agglomerans in grain as well as in the settled grain and flour dust was found to be high, ranging from 10(4)-10(8) CFU/g, while in the air polluted with grain or flour dust it ranged from 10(3)-10(5) CFU/m(3) and formed 73.2-96% of the total airborne Gram-negative bacteria. The concentration of P. agglomerans was also relatively high in the air of the facilities processing herbs and other plant materials, while it was lower in animal farms and in wood processing facilities. Pantoea agglomerans produces a biologically-potent endotoxin (cell wall lipopolysaccharide, LPS). The significant part of this endotoxin occurs in dusts in the form of virus-sized globular nanoparticles measuring 10-50 nm that could be described as the 'endotoxin super-macromolecules'. A highly significant relationship was found (R=0.804, P=0.000927) between the concentration of the viable P. agglomerans in the air of various agricultural and wood industry settings and the concentration of bacterial endotoxin in the air, as assessed by the Limulus test. Although this result may be interfered by the presence of endotoxin produced by other Gram-negative species, it unequivocally suggests the primary role of the P. agglomerans endotoxin as an adverse agent in the agricultural working environment, causing toxic pneumonitis (ODTS). Numerous experiments by the inhalation exposure of animals to various extracts of P. agglomerans strains isolated from grain dust, including endotoxin isolated with trichloroacetic acid (LPS-TCA), endotoxin nanoparticles isolated in sucrose gradient (VECN), and mixture of proteins and endotoxin obtained

  2. The development of allergic inflammation in a murine house dust mite asthma model is suppressed by synbiotic mixtures of non-digestible oligosaccharides and Bifidobacterium breve M-16V.

    Science.gov (United States)

    Verheijden, K A T; Willemsen, L E M; Braber, S; Leusink-Muis, T; Jeurink, P V; Garssen, J; Kraneveld, A D; Folkerts, G

    2016-04-01

    The incidence and severity of allergic asthma is rising, and novel strategies to prevent or treat this disease are needed. This study investigated the effects of different mixtures of non-digestible oligosaccharides combined with Bifidobacterium breve M-16V (BB) on the development of allergic airway inflammation in an animal model for house dust mite (HDM)-induced allergic asthma. BALB/c mice were sensitized intranasally (i.n.) with HDM and subsequently challenged (i.n.) with PBS or HDM while being fed diets containing different oligosaccharide mixtures in combination with BB or an isocaloric identical control diet. Bronchoalveolar lavage fluid (BALF) inflammatory cell influx, chemokine and cytokine concentrations in lung homogenates and supernatants of ex vivo HDM-restimulated lung cells were analyzed. The HDM-induced influx of eosinophils and lymphocytes was reduced by the diet containing the short-chain and long-chain fructo-oligosaccharides and BB (FFBB). In addition to the HDM-induced cell influx, concentrations of IL-33, CCL17, CCL22, IL-6, IL-13 and IL-5 were increased in supernatants of lung homogenates or BALF and IL-4, IFN-γ and IL-10 were increased in restimulated lung cell suspensions of HDM-allergic mice. The diet containing FFBB reduced IL-6, IFN-γ, IL-4 and IL-10 concentrations, whereas the combination of galacto-oligosaccharides and long-chain fructo-oligosaccharides with BB was less potent in this model. These findings show that synbiotic dietary supplementation can affect respiratory allergic inflammation induced by HDM. The combination of FFBB was most effective in the prevention of HDM-induced airway inflammation in mice.

  3. High temperature and dust load in mines

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, V V; Bolonova, L N; Donets, I K; Mukhina, K Sh

    1989-02-01

    Presents results of study of combined load on the human system of heat and dust as encountered in deep coal mines in the Donbass. Groups of coal miners were studied to ascertain the state of their lungs, particularly the presence of free silica, dust, collagen, etc. The sickness records for a number of Donbass mining associations for the past 25 years were analyzed. Multiple regression analysis of the data obtained led to curves relating the number of shifts worked to dust levels, pulmonary ventilation (0.01 and 0.04 m/sup 3//min) and maximum admissible dust concentrations (2, 4, 6 and 10 mg/m/sup 3/). In the 25-35 C temperature range a rise of 1 C is accompanied by increases of 9.9% in dust mass, 15.4% in silica content, 10.7% in mineral impurities and 2.3% in pathomorphological changes in the lungs. An adjustment to the maximum admissible concentration correction coefficient of 10% for every 1 C over 26 C is recommended. 1 ref.

  4. Computational algorithm for molybdenite concentrate annealing

    International Nuclear Information System (INIS)

    Alkatseva, V.M.

    1995-01-01

    Computational algorithm is presented for annealing of molybdenite concentrate with granulated return dust and that of granulated molybdenite concentrate. The algorithm differs from the known analogies for sulphide raw material annealing by including the calculation of return dust mass in stationary annealing; the latter quantity varies form the return dust mass value obtained in the first iteration step. Masses of solid products are determined by distribution of concentrate annealing products, including return dust and benthonite. The algorithm is applied to computations for annealing of other sulphide materials. 3 refs

  5. Pantoea agglomerans : a mysterious bacterium of evil and good. Part II. Deleterious effects: Dust-borne endotoxins and allergens – focus on grain dust, other agricultural dusts and wood dust

    Directory of Open Access Journals (Sweden)

    Jacek Dutkiewicz

    2015-12-01

    Full Text Available Pantoea agglomerans , a Gram-negative bacterium developing in a variety of plants as epiphyte or endophyte is particularly common in grain and grain dust, and has been identified by an interdisciplinary group from Lublin, eastern Poland, as a causative agent of work-related diseases associated with exposure to grain dust and other agricultural dusts. The concentration of [i]P. agglomerans[/i] in grain as well as in the settled grain and flour dust was found to be high, ranging from 10 4 –10 8 CFU/g, while in the air polluted with grain or flour dust it ranged from 10 3 –10 5 CFU/m 3 and formed 73.2–96% of the total airborne Gram-negative bacteria. The concentration of P. agglomerans was also relatively high in the air of the facilities processing herbs and other plant materials, while it was lower in animal farms and in wood processing facilities. Pantoea agglomerans produces a biologically-potent endotoxin (cell wall lipopolysaccharide, LPS. The significant part of this endotoxin occurs in dusts in the form of virus-sized globular nanoparticles measuring 10–50 nm that could be described as the ‘endotoxin super-macromolecules’. A highly significant relationship was found (R=0.804, P=0.000927 between the concentration of the viable P. agglomerans in the air of various agricultural and wood industry settings and the concentration of bacterial endotoxin in the air, as assessed by the Limulus test. Although this result may be interfered by the presence of endotoxin produced by other Gram-negative species, it unequivocally suggests the primary role of the P. agglomerans endotoxin as an adverse agent in the agricultural working environment, causing toxic pneumonitis (ODTS. Numerous experiments by the inhalation exposure of animals to various extracts of P. agglomerans strains isolated from grain dust, including endotoxin isolated with trichloroacetic acid (LPS-TCA, endotoxin nanoparticles isolated in sucrose gradient (VECN, and mixture of

  6. Analysis of basophil activation by flow cytometry in pediatric house dust mite allergy.

    Science.gov (United States)

    González-Muñoz, Miguel; Villota, Julian; Moneo, Ignacio

    2008-06-01

    Detection of allergen-induced basophil activation by flow cytometry has been shown to be a useful tool for allergy diagnosis. The aim of this study was to assess the potential of this technique for the diagnosis of pediatric house dust mite allergy. Quantification of total and specific IgE and basophil activation test were performed to evaluate mite allergic (n = 24), atopic (n = 23), and non-allergic children (n = 9). Allergen-induced basophil activation was detected as a CD63-upregulation. Receiver operating characteristics (ROC) curve analysis was performed to calculate the optimal cut-off value of activated basophils discriminating mite allergic and non-allergic children. ROC curve analysis yielded a threshold value of 18% activated basophils when mite-sensitized and atopic children were studied [area under the curve (AUC) = 0.99, 95% confidence interval (CI) = 0.97-1.01, p 43 kU/l) values for Dermatophagoides pteronyssinus allergen. They also showed positive prick (wheal diameter >1.0 cm) and basophil activation (>87%) tests and high specific IgE (>100 kU/l) with shrimp allergen. Shrimp sensitization was demonstrated by high levels of Pen a 1-specific IgE (>100 kU/l). Cross-reactivity between mite and shrimp was confirmed by fluorescence enzyme immunoassay (FEIA-CAP) inhibition study in these two cases. This study demonstrated that the analysis of allergen-induced CD63 upregulation by flow cytometry is a reliable tool for diagnosis of mite allergy in pediatric patients, with sensitivity similar to routine diagnostic tests and a higher specificity. Furthermore, this method can provide additional information in case of disagreement between in vivo and in vitro test results.

  7. Dust exposure in workers from grain storage facilities in Costa Rica.

    Science.gov (United States)

    Rodríguez-Zamora, María G; Medina-Escobar, Lourdes; Mora, Glend; Zock, Jan-Paul; van Wendel de Joode, Berna; Mora, Ana M

    2017-08-01

    About 12 million workers are involved in the production of basic grains in Central America. However, few studies in the region have examined the occupational factors associated with inhalable dust exposure. (i) To assess the exposure to inhalable dust in workers from rice, maize, and wheat storage facilities in Costa Rica; (ii) to examine the occupational factors associated with this exposure; and (iii) to measure concentrations of respirable and thoracic particles in different areas of the storage facilities. We measured inhalable (dust concentrations in 176 personal samples collected from 136 workers of eight grain storage facilities in Costa Rica. We also measured respirable (dust particles in several areas of the storage facilities. Geometric mean (GM) and geometric standard deviation (GSD) inhalable dust concentrations were 2.0mg/m 3 and 7.8 (range=dust concentrations were associated with job category [GM for category/GM for administrative staff and other workers (95% CI)=4.4 (2.6, 7.2) for packing; 20.4 (12.3, 34.7) for dehulling; 109.6 (50.1, 234.4) for unloading in flat bed sheds; 24.0 (14.5, 39.8) for unloading in pits; and 31.6 (18.6, 52.5) for drying], and cleaning task [15.8 (95% CI: 10.0, 26.3) in workers who cleaned in addition to their regular tasks]. Higher area concentrations of thoracic dust particles were found in wheat (GM and GSD=4.3mg/m 3 and 4.5) and maize (3.0mg/m 3 and 3.9) storage facilities, and in grain drying (2.3mg/m 3 and 3.1) and unloading (1.5mg/m 3 and 4.8) areas. Operators of grain storage facilities showed elevated inhalable dust concentrations, mostly above international exposure limits. Better engineering and administrative controls are needed. Copyright © 2017 Elsevier GmbH. All rights reserved.

  8. Development of novel immunogens on the hypersensitivity induced proteins by the combination of radiation technology and biotechnology

    International Nuclear Information System (INIS)

    Lee, Ju Woon; Byun, Myung Woo; Kim, Jae Hun; Seo, Ji Hyun

    2006-01-01

    The irradiated house dust mite allergen showed the conformational change with disappearance of major allergen and aggregation to higher molecular weights. The irradiated house dust mite allergens showed the change of epitope from results of the reduction of binding ability of house dust mite-allergic patients' serum (IgE) and polyclonal rabbit IgG against the irradiated allergens. In assessment of immunogenicity and allergenicity, irradiated house dust mite allergen showed the reduction of allergenicity with decrease of concentration for IL-4 and IL-5, the cytokine inducing allergy. For the assessment of the possibility as therapeutic immunogen of irradiated house dust mite allergen, allergic induced-mouse model were established. Irradiated allergen showed the maintainment of immunogenicity and the reduction of allergenicity from the result of maintain of IgG and reduction of IgE. Blue spots against irradiated allergen decreased raising with radiation dose in passive cutaneous anaphylaxis. The therapeutic effect was measured by reduction of house dust mite-specific IgE, IL-4 and IL-5. Induction of allergy after immunization of irradiated house dust mite allergen decreased by the reduction of house dust mite-specific IgE and IL-4 release. Therefore, house dust mite allergen modified by irradiation could be used as an effective immunogens for the prevention and treatment of allergy

  9. Residential metal contamination and potential health risks of exposure in adobe brick houses in Potosí, Bolivia.

    Science.gov (United States)

    McEwen, Abigail R; Hsu-Kim, Heileen; Robins, Nicholas A; Hagan, Nicole A; Halabi, Susan; Barras, Olivo; Richter, Daniel deB; Vandenberg, John J

    2016-08-15

    Potosí, Bolivia, is the site of centuries of historic and present-day mining of the Cerro Rico, a mountain known for its rich polymetallic deposits, and was the site of large-scale Colonial era silver refining operations. In this study, the concentrations of several metal and metalloid elements were quantified in adobe brick, dirt floor, and surface dust samples from 49 houses in Potosí. Median concentrations of total mercury (Hg), lead (Pb), and arsenic (As) were significantly greater than concentrations measured in Sucre, Bolivia, a non-mining town, and exceeded US-based soil screening levels. Adobe brick samples were further analyzed for bioaccessible concentrations of trace elements using a simulated gastric fluid (GF) extraction. Median GF extractable concentrations of Hg, As, and Pb were 0.085, 13.9, and 32.2% of the total element concentration, respectively. Total and GF extractable concentrations of Hg, As, and Pb were used to estimate exposure and potential health risks to children following incidental ingestion of adobe brick particles. Risks were assessed using a range of potential ingestion rates (50-1000mg/day). Overall, the results of the risk assessment show that the majority of households sampled contained concentrations of bioaccessible Pb and As, but not Hg, that represent a potential health risk. Even at the lowest ingestion rate considered, the majority of households exceeded the risk threshold for Pb, indicating that the concentrations of this metal are of particular concern. To our knowledge, this is the first study to quantify key trace elements in building materials in adobe brick houses and the results indicate that these houses are a potential source of exposure to metals and metalloids in South American mining communities. Additional studies are needed to fully characterize personal exposure and to understand potential adverse health outcomes within the community. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Saharan dust event impacts on cloud formation and radiation over Western Europe

    Directory of Open Access Journals (Sweden)

    M. Bangert

    2012-05-01

    Full Text Available We investigated the impact of mineral dust particles on clouds, radiation and atmospheric state during a strong Saharan dust event over Europe in May 2008, applying a comprehensive online-coupled regional model framework that explicitly treats particle microphysics and chemical composition. Sophisticated parameterizations for aerosol activation and ice nucleation, together with two-moment cloud microphysics are used to calculate the interaction of the different particles with clouds depending on their physical and chemical properties.

    The impact of dust on cloud droplet number concentration was found to be low, with just a slight increase in cloud droplet number concentration for both uncoated and coated dust. For temperatures lower than the level of homogeneous freezing, no significant impact of dust on the number and mass concentration of ice crystals was found, though the concentration of frozen dust particles reached up to 100 l−1 during the ice nucleation events. Mineral dust particles were found to have the largest impact on clouds in a temperature range between freezing level and the level of homogeneous freezing, where they determined the number concentration of ice crystals due to efficient heterogeneous freezing of the dust particles and modified the glaciation of mixed phase clouds.

    Our simulations show that during the dust events, ice crystals concentrations were increased twofold in this temperature range (compared to if dust interactions are neglected. This had a significant impact on the cloud optical properties, causing a reduction in the incoming short-wave radiation at the surface up to −75 W m−2. Including the direct interaction of dust with radiation caused an additional reduction in the incoming short-wave radiation by 40 to 80 W m−2, and the incoming long-wave radiation at the surface was increased significantly in the order of +10 W m−2.

    The

  11. Creation of Wood Dust during Wood Processing: Size Analysis, Dust Separation, and Occupational Health

    Directory of Open Access Journals (Sweden)

    Eva Mračková

    2015-11-01

    Full Text Available Mechanical separators and fabric filters are being used to remove airborne fine particles generated during the processing and handling of wood. Such particles might have a harmful effect on employee health, not only in small- but also in large-scale wood processing facilities. The amount of wood dust and its dispersion conditions vary according to geometric boundary conditions. Thus, the dispersion conditions could be changed by changing the linear size of the particles. Moreover, the smaller the particles are, the more harmful they can be. It is necessary to become familiar with properties, from a health point of view, of wood dust generated from processing. Wood dust has to be sucked away from the processing area. The fractional separation efficiency of wood dust can be improved using exhaust and filtering devices. Filtration efficiency depends on moisture content, particle size, and device performance. Because of the carcinogenicity of wood dust, the concentration of wood dust in air has to be monitored regularly. Based on the results hereof, a conclusion can be made that both mechanical separators of types SEA and SEB as well as the fabric filters with FINET PES 1 textile are suitable for the separation of wet saw dust from all types of wooden waste produced within the process.

  12. Phthalate and PAH concentrations in dust collected from Danish homes and daycare centers

    DEFF Research Database (Denmark)

    Langer, Sarka; Weschler, Charles J.; Fischer, Andreas

    2010-01-01

    (diethyl phthalate (DEP), di(n-butyl) phthalate (DnBP), di(isobutyl) phthalate (DiBP), butyl benzyl phthalate (BBzP), di(2-ethylhexyl) phthalate (DEHP)) and three PAHs (pyrene, benz[a]anthracene (B[a]A) and benzo[a]pyrene (B[a]P)). The three PAHs and DEHP were detected in dust samples from all sites, while...... DEP. DnBP, DiBP and BBzP were detected in more than 75% of the bedrooms and more than 90% of the daycare centers. The dust mass-fractions of both phthalates and PAHs were log-normally distributed. With the exception of DEP, the mass-fractions of phthalates in dust were higher in daycare centers than...... homes: PAH mass-fractions in dust were similar in the two locations. There was no correlation among the different phthalates in either homes or daycare centers. In contrast, the PAH were correlated with one another more strongly so in homes (R-2 = 0.80-0.90) than in daycare centers (R-2 = 0...

  13. Desert Dust Outbreaks in Southern Europe: Contribution to Daily PM10 Concentrations and Short-Term Associations with Mortality and Hospital Admissions

    Science.gov (United States)

    Stafoggia, Massimo; Zauli-Sajani, Stefano; Pey, Jorge; Samoli, Evangelia; Alessandrini, Ester; Basagaña, Xavier; Cernigliaro, Achille; Chiusolo, Monica; Demaria, Moreno; Díaz, Julio; Faustini, Annunziata; Katsouyanni, Klea; Kelessis, Apostolos G.; Linares, Cristina; Marchesi, Stefano; Medina, Sylvia; Pandolfi, Paolo; Pérez, Noemí; Querol, Xavier; Randi, Giorgia; Ranzi, Andrea; Tobias, Aurelio; Forastiere, Francesco

    2015-01-01

    Background: Evidence on the association between short-term exposure to desert dust and health outcomes is controversial. Objectives: We aimed to estimate the short-term effects of particulate matter ≤ 10 μm (PM10) on mortality and hospital admissions in 13 Southern European cities, distinguishing between PM10 originating from the desert and from other sources. Methods: We identified desert dust advection days in multiple Mediterranean areas for 2001–2010 by combining modeling tools, back-trajectories, and satellite data. For each advection day, we estimated PM10 concentrations originating from desert, and computed PM10 from other sources by difference. We fitted city-specific Poisson regression models to estimate the association between PM from different sources (desert and non-desert) and daily mortality and emergency hospitalizations. Finally, we pooled city-specific results in a random-effects meta-analysis. Results: On average, 15% of days were affected by desert dust at ground level (desert PM10 > 0 μg/m3). Most episodes occurred in spring–summer, with increasing gradient of both frequency and intensity north–south and west–east of the Mediterranean basin. We found significant associations of both PM10 concentrations with mortality. Increases of 10 μg/m3 in non-desert and desert PM10 (lag 0–1 days) were associated with increases in natural mortality of 0.55% (95% CI: 0.24, 0.87%) and 0.65% (95% CI: 0.24, 1.06%), respectively. Similar associations were estimated for cardio-respiratory mortality and hospital admissions. Conclusions: PM10 originating from the desert was positively associated with mortality and hospitalizations in Southern Europe. Policy measures should aim at reducing population exposure to anthropogenic airborne particles even in areas with large contribution from desert dust advections. Citation: Stafoggia M, Zauli-Sajani S, Pey J, Samoli E, Alessandrini E, Basagaña X, Cernigliaro A, Chiusolo M, Demaria M, Díaz J, Faustini A

  14. Desert Dust Outbreaks in Southern Europe: Contribution to Daily PM₁₀ Concentrations and Short-Term Associations with Mortality and Hospital Admissions.

    Science.gov (United States)

    Stafoggia, Massimo; Zauli-Sajani, Stefano; Pey, Jorge; Samoli, Evangelia; Alessandrini, Ester; Basagaña, Xavier; Cernigliaro, Achille; Chiusolo, Monica; Demaria, Moreno; Díaz, Julio; Faustini, Annunziata; Katsouyanni, Klea; Kelessis, Apostolos G; Linares, Cristina; Marchesi, Stefano; Medina, Sylvia; Pandolfi, Paolo; Pérez, Noemí; Querol, Xavier; Randi, Giorgia; Ranzi, Andrea; Tobias, Aurelio; Forastiere, Francesco

    2016-04-01

    Evidence on the association between short-term exposure to desert dust and health outcomes is controversial. We aimed to estimate the short-term effects of particulate matter ≤ 10 μm (PM10) on mortality and hospital admissions in 13 Southern European cities, distinguishing between PM10 originating from the desert and from other sources. We identified desert dust advection days in multiple Mediterranean areas for 2001-2010 by combining modeling tools, back-trajectories, and satellite data. For each advection day, we estimated PM10 concentrations originating from desert, and computed PM10 from other sources by difference. We fitted city-specific Poisson regression models to estimate the association between PM from different sources (desert and non-desert) and daily mortality and emergency hospitalizations. Finally, we pooled city-specific results in a random-effects meta-analysis. On average, 15% of days were affected by desert dust at ground level (desert PM10 > 0 μg/m3). Most episodes occurred in spring-summer, with increasing gradient of both frequency and intensity north-south and west-east of the Mediterranean basin. We found significant associations of both PM10 concentrations with mortality. Increases of 10 μg/m3 in non-desert and desert PM10 (lag 0-1 days) were associated with increases in natural mortality of 0.55% (95% CI: 0.24, 0.87%) and 0.65% (95% CI: 0.24, 1.06%), respectively. Similar associations were estimated for cardio-respiratory mortality and hospital admissions. PM10 originating from the desert was positively associated with mortality and hospitalizations in Southern Europe. Policy measures should aim at reducing population exposure to anthropogenic airborne particles even in areas with large contribution from desert dust advections. Stafoggia M, Zauli-Sajani S, Pey J, Samoli E, Alessandrini E, Basagaña X, Cernigliaro A, Chiusolo M, Demaria M, Díaz J, Faustini A, Katsouyanni K, Kelessis AG, Linares C, Marchesi S, Medina S, Pandolfi P, P

  15. Assessment of occupational exposure to wood dust in the Polish furniture industry

    Directory of Open Access Journals (Sweden)

    Małgorzata Szewczyńska

    2017-02-01

    Full Text Available Background: Occupational exposure to wood dust can be responsible for many different harmful health effects, especially in workers employed in the wood industry. The assessment of wood dust adverse effects to humans, as well as the interpretation of its concentration measurements carried out to assess potential occupational exposure are very difficult. First of all, it is due to possible occurrence of different kind of wood dust in the workplace air, namely wood dust from dozens of species of trees belonging to 2 kinds of botanical gymnosperms and angiosperms, as well as to its different chemical composition. Material and Methods: Total dust and respirable wood dust in the workplace air in the furniture industry was determined using the filtration-gravimetric method in accordance with Polish Standards PN-Z-04030-05:1991 and PN-Z-04030-06:1991. Air samples were collected based on the principles of individual dosimetry. Results: Total dust concentrations were 0.84–13.92 mg/m3 and inhalable fraction concentrations, obtained after the conversion of total dust by applying a conversion factor of 1.59, were 1.34–22.13 mg/m3. Respirable fraction concentrations were 0.38–4.04 mg/m3, which makes approx. 25% of the inhalable fraction on average. The highest concentrations occurred in grinding and the lowest during milling processes of materials used in the manufacture of furniture. Conclusions: The results indicate that the share of respirable fraction in the inhalable fraction of wood dust is considerable. Due to the determination of the threshold limit value (TLV for the inhalable fraction of wood dust, it is necessary to replace the previously used samplers for total dust with samplers that provide quantitative separation of wood dust inhalable fractions in accordance with the convention of this fraction as defined in PN-EN 481:1998. Med Pr 2017;68(1:45–60

  16. [Assessment of occupational exposure to wood dust in the Polish furniture industry].

    Science.gov (United States)

    Szewczyńska, Małgorzata; Pośniak, Małgorzata

    2017-02-28

    Occupational exposure to wood dust can be responsible for many different harmful health effects, especially in workers employed in the wood industry. The assessment of wood dust adverse effects to humans, as well as the interpretation of its concentration measurements carried out to assess potential occupational exposure are very difficult. First of all, it is due to possible occurrence of different kind of wood dust in the workplace air, namely wood dust from dozens of species of trees belonging to 2 kinds of botanical gymnosperms and angiosperms, as well as to its different chemical composition. Total dust and respirable wood dust in the workplace air in the furniture industry was determined using the filtration-gravimetric method in accordance with Polish Standards PN-Z-04030-05:1991 and PN-Z-04030-06:1991. Air samples were collected based on the principles of individual dosimetry. Total dust concentrations were 0.84-13.92 mg/m3 and inhalable fraction concentrations, obtained after the conversion of total dust by applying a conversion factor of 1.59, were 1.34-22.13 mg/m3. Respirable fraction concentrations were 0.38-4.04 mg/m3, which makes approx. 25% of the inhalable fraction on average. The highest concentrations occurred in grinding and the lowest during milling processes of materials used in the manufacture of furniture. The results indicate that the share of respirable fraction in the inhalable fraction of wood dust is considerable. Due to the determination of the threshold limit value (TLV) for the inhalable fraction of wood dust, it is necessary to replace the previously used samplers for total dust with samplers that provide quantitative separation of wood dust inhalable fractions in accordance with the convention of this fraction as defined in PN-EN 481:1998. Med Pr 2017;68(1):45-60. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  17. Radon in houses

    International Nuclear Information System (INIS)

    Toohey, R.E.; Essling, M.A.; Markun, F.

    1985-01-01

    The purpose of this study is to determine the concentrations of 222 Rn and its short-lived daughter products in the air of single-family houses in the midwestern US. During the past year, more than 200 houses were added to the study, resulting in a total of more than 400 houses. So far, results are available for 270 of these houses, equally divided between the Chicago area and Bloomsburg, Pennsylvania. 6 refs

  18. Research and development in dust and silicosis suppression

    Energy Technology Data Exchange (ETDEWEB)

    Breuer, H

    1975-08-21

    MAK values of 4 mg/m/sup 3/ for respirable dust containing quartz and 0.15 mg/m/sup 3/ for respirable quartz dust have been established for 5 years' exposure in West German hard coal mines. Routine gravimetric measurements were introduced in 1974 and these are supplemented by the digital Tyndallometer which indicates short-term variations. Gravimetric measurements have indicated the main sources of dust and improved dust suppression measures have considerably reduced respirable dust concentrations in some cases, e.g., by seam infusion, by spraying of the face machine path and at crushers, and by dedusters on heading machines.

  19. Bla g 1 allergen levels in Zagreb area household dust.

    Science.gov (United States)

    Prester, Ljerka; Macan, Jelena

    2011-03-01

    Cockroach allergy is a health problem in many parts of the world. In urban environments, indoor exposure to cockroach allergens involves a risk of asthma. The aim of this study was to measure the mass fraction of Bla g 1, a major allergen of the German cockroach (Blatella germanica) in 30 house samples, collected at random from Zagreb area households, Croatia. Dust samples were collected on cellulose filters by vacuuming living rooms floors. After extraction, Bla g 1 was detected using the commercial enzyme-linked immunosorbent assay (ELISA). Only four of the thirty households had detectable Bla g 1 levels, and only in one was its concentration higher than 2.0 U g(-1), the threshold associated with sensitisation. The Bla g 1 ELISA proved highly sensitive, with the detection limit of 0.12 U g(-1). The within- and between-assay imprecision was 8.9 % and 14.4 %, respectively, and accuracy 85 % to 120 %. Low Bla g 1 levels in the household dust support previously reported low prevalence of skin sensitisation to B. germanica among Zagreb residents. Further monitoring should reveal if there are differences in cockroach allergen exposure and sensitisation between households from other geographic areas in Croatia.

  20. Magnetic studies of dusts in the urban environment

    International Nuclear Information System (INIS)

    Xie, S.

    2000-12-01

    Dusts are one of the major public health concerns in the urban environment. This study investigates the application of magnetic techniques in the studies of urban dust pollution. Measurements of magnetic properties, element concentrations, and the organic matter content were carried out on Liverpool (UK) street dust and/or Bootle (UK) deposited dust. Mixed dominant ferrimagnetic phases are found in Liverpool street dust although magnetite is probably a major one. The partial susceptibility technique is able to model the contributions of main magnetic components satisfactorily in Liverpool street dust. There are similar spatial distributions for some measurements, such as χLF and Pb, whilst there are different patterns for some measurements, such as χLF and the organic matter content. There are good linear correlations between the organic matter content and some magnetic mineral concentration-related parameters for < 1mm (bulk) samples. Among them, frequency dependent susceptibility (χFD) shows the highest correlation coefficient value. χFD percentage demonstrates a significant correlation with the organic matter content for size fraction and bulk samples. This suggests that re-entrainment of soil is probably a major source of the organic material present in street dust. The ratio χARM /SIRM shows a highly significant correlation with the organic matter content for <150μm fraction samples. The study demonstrates that the simple, rapid, and non-destructive magnetic measurements may be used as proxies for the organic matter content in street dust. Associations between magnetic properties and element concentrations are investigated by using correlation analysis and factor analysis, which may be a potential approach for source identification of magnetic material in the environment. The study suggests that ferrimagnetic minerals are the dominant magnetic component in Bootle dust samples. Both studied sites show similar magnetic properties, but they can be

  1. Dust-Plasma Interactions

    International Nuclear Information System (INIS)

    Rosenberg, Marelene

    2005-01-01

    Our theoretical research on dust-plasma interactions has concentrated on three main areas: (a)studies of grain charging and applications; (b) waves and instabilities in weakly correlated dusty plasma with applications to space and laboratory plasmas; (c) waves in strongly coupled dusty plasmas.

  2. Elemental Concentration of Harmattan Dust Sample in Iwo and Oyo ...

    African Journals Online (AJOL)

    ADOWIE PERE

    According to Balogun (1979), two sources of dust plumes were identified .... metals. Heavy metals are known to be harmful to human health if they are more than the recommended ... Chemical. Characterization and Source Apportionment of.

  3. [Analysis and prevention of dust pollution caused by 5 common prosthetic materials].

    Science.gov (United States)

    Yang, Xiang-Wen; Wei, Bin; Zhu, Cao-Yun; Qian, Liang; Li, Yi-Han

    2017-10-01

    To analyze and evaluate dust pollution in prosthodontic clinic and make proposal for reasonable protection. This study analyzed the particle size, element composition and dust concentration of 5 materials which were commonly used in dental restorations (veneering ceramics, cobalt-chromium alloy, photosensitive plastic, hard base resin, advanced artificial teeth) by using scanning electron microscopy (SEM), X-ray energy dispersive spectrometer(EDS) and dust concentration laser tester, in order to assess the effects of prosthodontic dust posed on medical staff health and put forward reasonable suggestions for prevention and control of dust pollution. The particle size of veneering ceramics, cobalt-chromium alloy, photosensitive plastic, hard base resin and advanced artificial teeth was (2.15±3.00), (33.78±24.33), (7.78±11.86), (31.16±44.35) and (28.45±39.21)μm, respectively. The time weighted average respirable dust concentration of veneering ceramics was 0.393 mg/m 2 which was beyond the scope of national security. Dust pollution is serious in prosthodontic clinic to which we should pay more attention and take appropriate prevention measures.

  4. Effectiveness of multi-stage scrubbers in reducing emissions of air pollutants from pig houses

    OpenAIRE

    Zhao, Y.; Aarnink, A.J.A.; Jong, de, M.C.M.; Ogink, N.W.M.; Groot Koerkamp, P.W.G.

    2011-01-01

    Emissions of air pollutants from livestock houses may raise environmental problems and pose hazards to public health. They can be reduced by scrubbers installed at the air outlets of livestock houses. In this study, three multi-stage scrubbers were evaluated in terms of their effectiveness in reducing emissions of airborne dust, total bacteria, ammonia, and CO2 from pig houses in winter. The three multi-stage scrubbers were one double-stage scrubber (acid stage+ bio-filter), one double-stage ...

  5. [Asthma due to grain dust].

    Science.gov (United States)

    Baur, X; Preisser, A; Wegner, R

    2003-06-01

    The actual literature as well as two case reports described in detail show that grain dust induces asthmatic reactions and ODTS which are obviously not of allergic origin. For diagnosis occupational-type exposure tests are decisive whereas allergological testing usually is not. Endotoxins which are present in the grain dust samples in high concentrations have to be regarded as the major causative components. To avoid irreversible lung function impairment a comprehensive early diagnosis is necessary. Generally, a remarkable reduction of exposure to dust with high levels of airborne endotoxin in agriculture has to be achieved since in many workplaces corresponding exposures are still rather high.

  6. Dust Quantization and Effects on Agriculture Over Uttar Pradesh, India

    Science.gov (United States)

    Munshi, Pavel; Tiwari, Shubhansh

    2017-01-01

    Dust plays a very important role in the atmosphere and the biosphere. In this communication, the effect of atmospheric dust on the yields of certain crops grown in Uttar Pradesh, India is assessed. Coherent physical and thermodynamic fingerprints of dust parameters such as from Satellite data- KALPANA-1, MODIS, OMI, CALIPSO; Model data- DREAM, HYSPLIT, ECMWF; have been considered to run the APSIM model to derive the impacts. This paper assesses dust as a physical atmospheric phenomenon including its Long Range Transport (LRT) and dispersion along with considerable variations of Aerosol Optical Depths (AODs) over the subcontinent of India. While AODs significantly increase by more dust concentration, the local dispersion of pollutants is a major concern with deposition of atmospheric dust such as sulphates and other chemical constituents that affect agricultural land. An approach in atmospheric physics is also taken to parameterize the model outputs. This communication indicates dust to be a positive factor for the cultivation of certain crops such as wheat, maize in the experimental location. Initial results suggest that LRT dust is a viable counterpart to decrease the concentration of soil acidity and related parameters thus enhancing the vitality of crops.

  7. Toxicity of lunar dust assessed in inhalation-exposed rats.

    Science.gov (United States)

    Lam, Chiu-wing; Scully, Robert R; Zhang, Ye; Renne, Roger A; Hunter, Robert L; McCluskey, Richard A; Chen, Bean T; Castranova, Vincent; Driscoll, Kevin E; Gardner, Donald E; McClellan, Roger O; Cooper, Bonnie L; McKay, David S; Marshall, Linda; James, John T

    2013-10-01

    Humans will again set foot on the moon. The moon is covered by a layer of fine dust, which can pose a respiratory hazard. We investigated the pulmonary toxicity of lunar dust in rats exposed to 0, 2.1, 6.8, 20.8 and 60.6 mg/m(3) of respirable-size lunar dust for 4 weeks (6 h/day, 5 days/week); the aerosols in the nose-only exposure chambers were generated from a jet-mill ground preparation of a lunar soil collected during the Apollo 14 mission. After 4 weeks of exposure to air or lunar dust, groups of five rats were euthanized 1 day, 1 week, 4 weeks or 13 weeks after the last exposure for assessment of pulmonary toxicity. Biomarkers of toxicity assessed in bronchoalveolar fluids showed concentration-dependent changes; biomarkers that showed treatment effects were total cell and neutrophil counts, total protein concentrations and cellular enzymes (lactate dehydrogenase, glutamyl transferase and aspartate transaminase). No statistically significant differences in these biomarkers were detected between rats exposed to air and those exposed to the two low concentrations of lunar dust. Dose-dependent histopathology, including inflammation, septal thickening, fibrosis and granulomas, in the lung was observed at the two higher exposure concentrations. No lesions were detected in rats exposed to ≤6.8 mg/m(3). This 4-week exposure study in rats showed that 6.8 mg/m(3) was the highest no-observable-adverse-effect level (NOAEL). These results will be useful for assessing the health risk to humans of exposure to lunar dust, establishing human exposure limits and guiding the design of dust mitigation systems in lunar landers or habitats.

  8. Dust retaining properties of leaves of some tree species

    Energy Technology Data Exchange (ETDEWEB)

    Gusev, M I

    1960-05-01

    A study was made in Tashkent, Russia of the dust-retaining power of leaves of several tree species. Investigations were made in a park where these tree species were growing in close proximity, exposed to the effects of dust from the main city street and from the highway passing through the park. Observations on the dust-retaining power of leaves were made mostly during the summer and fall months. The dust-retaining power of leaves of different tree species varied with the dust concentration in the air. In the summer and fall when rains are scarce a steady accumulation of dust was observed on the surface of the leaves. 1 table.

  9. Development of novel immunogens on the hypersensitivity induced proteins by the combination of radiation technology and biotechnology

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ju Woon; Byun, Myung Woo; Kim, Jae Hun; Seo, Ji Hyun

    2006-01-15

    The irradiated house dust mite allergen showed the conformational change with disappearance of major allergen and aggregation to higher molecular weights. The irradiated house dust mite allergens showed the change of epitope from results of the reduction of binding ability of house dust mite-allergic patients' serum (IgE) and polyclonal rabbit IgG against the irradiated allergens. In assessment of immunogenicity and allergenicity, irradiated house dust mite allergen showed the reduction of allergenicity with decrease of concentration for IL-4 and IL-5, the cytokine inducing allergy. For the assessment of the possibility as therapeutic immunogen of irradiated house dust mite allergen, allergic induced-mouse model were established. Irradiated allergen showed the maintainment of immunogenicity and the reduction of allergenicity from the result of maintain of IgG and reduction of IgE. Blue spots against irradiated allergen decreased raising with radiation dose in passive cutaneous anaphylaxis. The therapeutic effect was measured by reduction of house dust mite-specific IgE, IL-4 and IL-5. Induction of allergy after immunization of irradiated house dust mite allergen decreased by the reduction of house dust mite-specific IgE and IL-4 release. Therefore, house dust mite allergen modified by irradiation could be used as an effective immunogens for the prevention and treatment of allergy.

  10. Immune response to allergens in sheep sensitized to house dust mite

    Directory of Open Access Journals (Sweden)

    Velden Joanne

    2008-10-01

    Full Text Available Abstract Background House dust mite (HDM allergens are a major cause of allergic asthma. Most studies using animal models of allergic asthma have used rodents sensitized with the 'un-natural' allergen ovalbumin. It has only recently been recognized that the use of animal models based on HDM provide a more relevant insight into the allergen-induced mechanisms that underpin human allergic disease. We have previously described a sheep model of human allergic asthma that uses Dermatophagoides pteronyssinus HDM. The present study extends our understanding of the immune effects of HDM and the allergens Der p 1 and Der p 2 in the sheep model of asthma. Methods Peripheral blood sera from non-sensitized (control sheep and sheep sensitized to HDM was collected to determine immunoglobulin (Ig reactivities to HDM, Der p 1 and Der p 2 by ELISA. Bronchoalveolar lavage (BAL fluid collected following allergen challenge was also assessed for the presence of HDM-specific antibodies. To examine the cellular immune response to HDM allergens, T cell proliferation and cutaneous responses were assessed in sensitized and control sheep. Results Strong HDM- and Der p 1-specific IgE, IgG1, IgG2 and IgA serum responses were observed in sensitized sheep, while detectable levels of HDM-specific IgG1 and IgA were seen in BAL fluid of allergen-challenged lungs. In contrast, minimal antibody reactivity was observed to Der p 2. Marked T cell proliferation and late phase cutaneous responses, accompanied by the recruitment of eosinophils, indicates the induction of a cellular and delayed-type hypersensitivity (DTH type II response by HDM and Der p 1 allergen, but not Der p 2. Conclusion This work characterizes the humoral and cellular immune effects of HDM extract and its major constituent allergens in sheep sensitized to HDM. The effects of allergen in HDM-sensitized sheep were detectable both locally and systemically, and probably mediated via enzymatic and immune actions of the

  11. Vaccination against IL-33 Inhibits Airway Hyperresponsiveness and Inflammation in a House Dust Mite Model of Asthma.

    Directory of Open Access Journals (Sweden)

    Ying Lei

    Full Text Available In several clinical and experimental studies IL-33 and its receptor have been found to play important roles in the development of asthma and allergic airway inflammation. We evaluated the effects of vaccination against IL-33 in a mouse model of airway inflammation induced by house dust mite (HDM allergen. Balb/c mice received the IL-33 vaccine subcutaneously, followed by intranasal administration of HDM for up to six weeks. Vaccination against IL-33 induced high titers of specific anti-IL-33 IgG antibodies that inhibited HDM-induced airway hyperresponsiveness (AHR in the conducting airways and tissue damping. The vaccination also attenuated the HDM-induced elevation in the numbers of eosinophils in bronchoalveolar lavage fluid (BALF and suppressed the accumulation of inflammatory cells in the airways. Furthermore, the levels of IL-17A, IL-25, IL-33 and TSLP in lung tissue homogenates were reduced by vaccination against IL-33. These observations demonstrate that vaccination against IL-33 inhibits HDM-induced development of AHR, airway inflammation and production of inflammatory cytokines. The results also indicate an important role of IL-33 in the regulation of AHR of the distal lung compartments. Thus, administration of such a vaccine is potentially an effective therapeutic tool for treating allergic asthma.

  12. Biomonitoring spatial and temporal impact of atmospheric dust from a cement industry

    International Nuclear Information System (INIS)

    Branquinho, Cristina; Gaio-Oliveira, Gisela; Augusto, Sofia; Pinho, Pedro; Maguas, Cristina; Correia, Otilia

    2008-01-01

    The objective of this work was to evaluate the spatial and temporal impact of dust-pollution in the vicinity of a cement industry, located in an area with dry climate. The spatial impact integrated over time was evaluated from the concentrations of Ca, Fe and Mg in in-situ Xanthoria parietina. The temporal pattern was assessed through one-month transplants of the lichen Ramalina canariensis. Four potential sources of atmospheric dust were evaluated: the limestone-quarry; the unpaved roads, the deposit area and the cement mill. Calcium concentration in lichens was considered the best cement-dust indicator. Different types of dust (clinker and grinded-limestone-dust) resulted in different time-patterns of Ca accumulation, which was also related with the different influence that wet and dry periods have in the lichen accumulation process. The dust pollution was found to be deposited locally and dependent on: the nature of dust particles and the volume and frequency of precipitation. - Biomonitoring Spatial and Temporal dust emissions in dry climates

  13. Biomonitoring spatial and temporal impact of atmospheric dust from a cement industry

    Energy Technology Data Exchange (ETDEWEB)

    Branquinho, Cristina [Universidade de Lisboa, Faculdade de Ciencias, Centro de Ecologia e Biologia Vegetal, Campo Grande, Edificio C2, Piso 4, 1749-016 Lisbon (Portugal); Universidade Atlantica, Antiga Fabrica da Polvora de Barcarena, 2745-615 Barcarena (Portugal)], E-mail: cmbranquinho@fc.ul.pt; Gaio-Oliveira, Gisela; Augusto, Sofia; Pinho, Pedro; Maguas, Cristina; Correia, Otilia [Universidade de Lisboa, Faculdade de Ciencias, Centro de Ecologia e Biologia Vegetal, Campo Grande, Edificio C2, Piso 4, 1749-016 Lisbon (Portugal)

    2008-01-15

    The objective of this work was to evaluate the spatial and temporal impact of dust-pollution in the vicinity of a cement industry, located in an area with dry climate. The spatial impact integrated over time was evaluated from the concentrations of Ca, Fe and Mg in in-situ Xanthoria parietina. The temporal pattern was assessed through one-month transplants of the lichen Ramalina canariensis. Four potential sources of atmospheric dust were evaluated: the limestone-quarry; the unpaved roads, the deposit area and the cement mill. Calcium concentration in lichens was considered the best cement-dust indicator. Different types of dust (clinker and grinded-limestone-dust) resulted in different time-patterns of Ca accumulation, which was also related with the different influence that wet and dry periods have in the lichen accumulation process. The dust pollution was found to be deposited locally and dependent on: the nature of dust particles and the volume and frequency of precipitation. - Biomonitoring Spatial and Temporal dust emissions in dry climates.

  14. An analysis of the dust deposition on solar photovoltaic modules.

    Science.gov (United States)

    Styszko, Katarzyna; Jaszczur, Marek; Teneta, Janusz; Hassan, Qusay; Burzyńska, Paulina; Marcinek, Ewelina; Łopian, Natalia; Samek, Lucyna

    2018-03-29

    Solid particles impair the performance of the photovoltaic (PV) modules. This results in power losses which lower the efficiency of the system as well as the increases of temperature which additionally decreases the performance and lifetime. The deposited dust chemical composition, concentration and formation of a dust layer on the PV surface differ significantly in reference to time and location. In this study, an evaluation of dust deposition on the PV front cover glass during the non-heating season in one of the most polluted European cities, Kraków, was performed. The time-dependent particle deposition and its correlation to the air pollution with particulate matter were analysed. Dust deposited on several identical PV modules during variable exposure periods (from 1 day up to 1 week) and the samples of total suspended particles (TSP) on quartz fibre filters using a low volume sampler were collected during the non-heating season in the period of 5 weeks. The concentration of TSP in the study period ranged between 12.5 and 60.05 μg m -3 while the concentration of PM10 observed in the Voivodeship Inspectorate of Environmental Protection traffic station, located 1.2 km from the TSP sampler, ranged from 14 to 47 μg m -3 . It was revealed that dust deposition density on a PV surface ranged from 7.5 to 42.1 mg m -2 for exposure periods of 1 day while the measured weekly dust deposition densities ranged from 25.8 to 277.0 mg m -2 . The precipitation volume and its intensity as well as humidity significantly influence the deposited dust. The rate of dust accumulation reaches approximately 40 mg m -2 day -1 in the no-precipitation period and it was at least two times higher than fluxes calculated on the basis of PM10 and TSP concentrations which suggest that additional forces such as electrostatic forces significantly influence dust deposition.

  15. Cosmological simulation with dust formation and destruction

    Science.gov (United States)

    Aoyama, Shohei; Hou, Kuan-Chou; Hirashita, Hiroyuki; Nagamine, Kentaro; Shimizu, Ikkoh

    2018-06-01

    To investigate the evolution of dust in a cosmological volume, we perform hydrodynamic simulations, in which the enrichment of metals and dust is treated self-consistently with star formation and stellar feedback. We consider dust evolution driven by dust production in stellar ejecta, dust destruction by sputtering, grain growth by accretion and coagulation, and grain disruption by shattering, and treat small and large grains separately to trace the grain size distribution. After confirming that our model nicely reproduces the observed relation between dust-to-gas ratio and metallicity for nearby galaxies, we concentrate on the dust abundance over the cosmological volume in this paper. The comoving dust mass density has a peak at redshift z ˜ 1-2, coincident with the observationally suggested dustiest epoch in the Universe. In the local Universe, roughly 10 per cent of the dust is contained in the intergalactic medium (IGM), where only 1/3-1/4 of the dust survives against dust destruction by sputtering. We also show that the dust mass function is roughly reproduced at ≲ 108 M⊙, while the massive end still has a discrepancy, which indicates the necessity of stronger feedback in massive galaxies. In addition, our model broadly reproduces the observed radial profile of dust surface density in the circum-galactic medium (CGM). While our model satisfies the observational constraints for the dust extinction on cosmological scales, it predicts that the dust in the CGM and IGM is dominated by large (>0.03 μm) grains, which is in tension with the steep reddening curves observed in the CGM.

  16. Cost-effectiveness of SQ® HDM SLIT-tablet in addition to pharmacotherapy for the treatment of house dust mite allergic rhinitis in Germany

    Directory of Open Access Journals (Sweden)

    Green W

    2017-02-01

    Full Text Available William Green,1 Jörg Kleine-Tebbe,2 Ludger Klimek,3 Julie Hahn-Pedersen,4 Jakob Nørgaard Andreasen,4 Matthew Taylor1 1York Health Economics Consortium, University of York, York, UK; 2Allergy and Asthma Center, Westend, Berlin, 3Center for Rhinology and Allergology, Wiesbaden, Germany; 4ALK-Abelló, Hørsholm, Denmark Background: Allergic rhinitis is a global health problem that burdens society due to associated health care costs and its impact on health. Standardized quality (SQ® house dust mite (HDM sublingual immunotherapy (SLIT-tablet is a sublingually administered allergy immunotherapy tablet for patients with persistent moderate to severe HDM allergic rhinitis despite use of allergy pharmacotherapy.Objective: To assess the cost-effectiveness of SQ HDM SLIT-tablet in Germany for patients suffering from HDM allergic rhinitis.Methods: A pharmacoeconomic analysis, based on data collected in a double-blinded, phase III randomized placebo-controlled trial (n=992, was undertaken to compare SQ HDM SLIT-tablet in addition to allergy pharmacotherapy to placebo plus allergy pharmacotherapy. Quality-adjusted life year (QALY scores and health care resource use data recorded in the trial were applied to each treatment group and extrapolated over a nine-year time horizon. A series of scenarios were used to investigate the impact of changes on long-term patient health for both treatment groups, which was measured by annual changes in QALY scores. Deterministic and probabilistic sensitivity analyses were also performed. Results: In the base case analysis, compared with allergy pharmacotherapy, SQ HDM SLIT-tablet led to a QALY gain of 0.31 at an incremental cost of €2,276 over the nine-year time horizon, equating to an incremental cost-effectiveness ratio of €7,519. The treatment was cost-effective for all scenarios analyzed; however, results were sensitive to changes in individual parameter values during the deterministic sensitivity analysis

  17. THE VISUALIZATION METHOD OF THE 3D CONCENTRATION DISTRIBUTION OF ASIAN DUST IN THE GOOGLE EARTH

    Directory of Open Access Journals (Sweden)

    W. Okuda

    2012-07-01

    Full Text Available The Asian dust (called "Kosa" in Japan transported from desert areas in the northern China often covers over East Asia in the late winter and spring seasons. In this study, first of all, for dust events observed at various places in Japan on April 1, 2007 and March 21, 2010, the long-range transport simulation of Asian dust from desert areas in the northern China to Japan is carried out. Next, the method for representing 3D dust clouds by means of the image overlay functionality provided in the Google Earth is described. Since it is very difficult to display 3D dust clouds along the curvature of the Earth on the global scale, the 3D dust cloud distributed at the altitude of about 6300m was divided into many thin layers, each of which is the same thickness. After each of layers was transformed to the image layer, each image layer was displayed at the appropriate altitude in the Google Earth. Thus obtained image layers were displayed every an hour in the Google Earth. Finally, it is shown that 3D Asian dust clouds generated by the method described in this study are represented as smooth 3D cloud objects even if we looked at Asian dust clouds transversely in the Google Earth.

  18. High Proportions of Sub-micron Particulate Matter in Icelandic Dust Storms in 2015

    Science.gov (United States)

    Dagsson Waldhauserova, Pavla; Arnalds, Olafur; Olafsson, Haraldur; Magnusdottir, Agnes

    2017-04-01

    Iceland is extremely active dust region and desert areas of over 44,000 km2 acknowledge Iceland as the largest Arctic and European desert. Frequent dust events, up to 135 dust days annually, transport dust particles far distances towards the Arctic and Europe. Satellite MODIS pictures have revealed dust plumes exceeding 1,000 km. The annual dust deposition was calculated as 40.1 million tons yr-1. Two dust storms were measured in transverse horizontal profile about 90 km far from different dust sources in southwestern Iceland in the summer of 2015. Aerosol monitor DustTrak DRX 8533EP was used to measure PM mass concentrations corresponding to PM1, PM2.5, PM4, PM10 and the total PM15 at several places within the dust plume. Images from camera network operated by the Icelandic Road and Coastal Administration were used to estimate the visibility and spatial extent of measured dust events. A numerical simulation of surface winds was carried out with the numerical model HIRLAM with horizontal resolution of 5 km and used to calculate the total dust flux from the sources. The in situ measurements inside the dust plumes showed that aeolian dust can be very fine. The study highlights that suspended volcanic dust in Iceland causes air pollution with extremely high PM1 concentrations comparable to the polluted urban stations in Europe or Asia rather than reported dust event observations from around the world. The PM1/PM2.5 ratios are generally low during dust storms outside of Iceland, much lower than > 0.9 and PM1/PM10 ratios of 0.34-0.63 found in our study. It shows that Icelandic volcanic dust consists of higher proportion of submicron particles compared to crustal dust. The submicron particles are predicted to travel long distances. Moreover, such submicron particles pose considerable health risk because of high potential for entering the lungs. Icelandic volcanic glass has often fine pipe-vesicular structures known from asbestos and high content of heavy metals. Previous

  19. Control of dust hazards in mines

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, V V

    1981-09-01

    This paper analyzes health hazards associated with air pollution by respirable coal dust which causes pneumoconioses. The following directions in pneumoconioses prevention are discussed: improved protective systems (e.g. respirators), mining schemes optimized from a health hazards point of view, correct determination of the maximum permissible level of respirable dusts, reducing working time. Safety regulations in the USSR on the critical amount of coal dust in the miner respiratory system are insufficient as the 20 g limit is too high and does not guarantee safety. Using regression analysis influence of the factors which cause pneumoconioses is analyzed. This influence is described by an equation which considers the following factors: number of shifts associated with contact of a miner with coal dusts, dust concentration in mine air, amount of air with coal dust being respirated, miner's age, years as miner, coal rank. It is stated that use of the proposed equation (derived by computer calculations) permits the safe working time to be correctly determined considering all factors which cause pneumoconioses.

  20. Nasal lavage cellularity, grain dust, and airflow obstruction.

    Science.gov (United States)

    Blaski, C A; Watt, J L; Quinn, T J; Thorne, P S; Schwartz, D A

    1996-04-01

    To evaluate the clinical utility of nasal lavage (NL), we performed post-work shift NL on 172 grain workers and 78 postal worker control subjects. The grain worker group included a higher percentage of current smokers (25.7% vs 16.7%) and a lower percentage of former smokers (21.15% vs 35.9%) compared with the postal workers. The control subjects included more female workers and were slightly older than the grain workers. Compared with the postal workers, the grain workers were exposed to significantly greater concentrations of total dust (0.1 +/- 0.0 vs 6.8 +/- 1.4 mg/m3; mean +/- SEM) and total endotoxin (4.3 +/- 0.8 vs 2,372.4 +/- 653.8 endotoxin units/m3). NL from gain workers showed a higher concentration of total cells (55,000 +/- 14,000 vs 25,000 +/- 5,000 cells per milliliter; p=0.03), a higher concentration of squamous epithelial cells (17,029.0 +/- 4,177 .0 vs 7,103.7 +/- 1,479.8 cells per milliliter; p=0.03), and a higher concentration of neutrophils (40,058.0 +/- 12,803.2 vs 17,891.0 +/- 3,822.3 cells per milliliter; p=0.10) compared with postal workers. Importantly, these differences in NL cellularity between grain workers and postal workers were observed within the three strata of smokers. To further assess the importance of total cells, squamous epithelial cells, and neutrophils in the NL fluid of grain workers, we investigated the relationship between these cell concentrations and (1) measures of dust and endotoxin exposure during the work shift. (2) spirometric measures of airflow obtained immediately before the NL, and (3) work-related respiratory symptoms. The concentration of total cells, the concentration of squamous epithelial cells, or the concentration of neutrophils in the NL was not associated with ambient levels of dust or endotoxin, with baseline or cross-shift changes in lung function, or with work-related respiratory symptoms. These findings suggest that increased NL cellularity may be seen in workers exposed to high dust levels

  1. Exposure to dust mixtures containing free crystalline silica and mineral fibers

    International Nuclear Information System (INIS)

    Wozniak, H.; Wiecek, E.; Bielichowska-Cybula, G.

    1996-01-01

    Exposure to dust mixture containing at the same time respirable mineral fibres and free crystalline silica may occur in Poland in mines and in the Lower Silesia plants processing mineral raw materials as well as in all plants which use asbestos products and MMMF. Workposts where thermal insulation is exchange with possible phase transformations during operations under conditions of high temperature, expose particularly complex problems. In the work environment of this kind, dust concentration of free crystalline silica becomes important but not sufficient criterion for evaluating working conditions and it may be misleading. A range of studies indispensable for the proper evaluation of exposure to dust, covering together with measurement of dust and SiO 2 concentrations, determination of the mineral composition of dust, was developed. It was also found that the acceptable level of risk for neoplastic disease, namely 10(-3) can be attained in the work environment only if the concentration ranges from 0.05 to 0.1 f/cm 3 , that is equal to 20% of MAC value which is now binding in Poland. Cancer risk (lung cancer and mesothelioma jointly) during a 20-year exposure to concentrations equal to present MAC values should be estimated as about 10(-2) what indicates that risk is too high and it is necessary to diminish MAC values for asbestos dust. (author). 17 refs, 3 tabs

  2. Contamination of indoor dust and air by polychlorinated biphenyls and brominated flame retardants and relevance of non-dietary exposure in Vietnamese informal e-waste recycling sites.

    Science.gov (United States)

    Tue, Nguyen Minh; Takahashi, Shin; Suzuki, Go; Isobe, Tomohiko; Viet, Pham Hung; Kobara, Yuso; Seike, Nobuyasu; Zhang, Gan; Sudaryanto, Agus; Tanabe, Shinsuke

    2013-01-01

    This study investigated the occurrence of polychlorinated biphenyls (PCBs), and several additive brominated flame retardants (BFRs) in indoor dust and air from two Vietnamese informal e-waste recycling sites (EWRSs) and an urban site in order to assess the relevance of these media for human exposure. The levels of polybrominated diphenyl ethers (PBDEs), hexabromocyclododecane (HBCD), 1,2-bis-(2,4,6-tribromophenoxy)ethane (BTBPE) and decabromodiphenyl ethane (DBDPE) in settled house dust from the EWRSs (130-12,000, 5.4-400, 5.2-620 and 31-1400 ng g(-1), respectively) were significantly higher than in urban house dust but the levels of PCBs (4.8-320 ng g(-1)) were not higher. The levels of PCBs and PBDEs in air at e-waste recycling houses (1000-1800 and 620-720 pg m(-3), respectively), determined using passive sampling, were also higher compared with non-e-waste houses. The composition of BFRs in EWRS samples suggests the influence from high-temperature processes and occurrence of waste materials containing older BFR formulations. Results of daily intake estimation for e-waste recycling workers are in good agreement with the accumulation patterns previously observed in human milk and indicate that dust ingestion contributes a large portion of the PBDE intake (60%-88%), and air inhalation to the low-chlorinated PCB intake (>80% for triCBs) due to their high levels in dust and air, respectively. Further investigation of both indoor dust and air as the exposure media for other e-waste recycling-related contaminants and assessment of health risk associated with exposure to these contaminant mixtures is necessary. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Vertical transport of desert particulates by dust devils and clear thermals

    International Nuclear Information System (INIS)

    Sinclair, P.C.

    1974-01-01

    While the vertical and horizontal transport of natural surface material by dust devils is not in itself a critical environmental problem, the transport and downwind fallout of toxic or hazardous materials from dust devil activity may be a contributing factor in the development of future ecological-biological problems. Direct quantitative measurements of the dust particle size distribution near and within the visible dust devil vortex and analyses of the upper level clear thermal plume have been made to provide estimates of the vertical and horizontal transport of long half-life radioactive substances such as plutonium. Preliminary measurements and calculations of dust concentrations within dust devils indicate that over 7 x 10 3 tons of desert dust and sand may be transported downwind from an area 285 km 2 during an average dust devil season (May to August). Near the ground these dust concentrations contain particles in the size range from approximately 1 μm to 250 μm diameter. Since the vertical velocity distribution greatly exceeds the particle(s) fall velocities, the detrainment of particles within the vortex is controlled primarily by the spatial distribution of the radial (v/sub r/) and tangential (v/sub theta/) velocity fields. Above the visible dust devil vortex, a clear thermal plume may extend upward to 15,000 to 18,000 ft MSL. A new airborne sampling and air data system has been developed to provide direct measurements of the dust concentration and air motion near and within the upper thermal plume. The air sampler has been designed to operate isokinetically over a considerable portion of the low-speed flight regime of a light aircraft. A strapped down, gyro-reference platform and a boom-vane system is used to determine the vertical air motions as well as the temperature and turbulence structure within the thermal plume. (U.S.)

  4. The role of endotoxin in grain dust-induced lung disease.

    Science.gov (United States)

    Schwartz, D A; Thorne, P S; Yagla, S J; Burmeister, L F; Olenchock, S A; Watt, J L; Quinn, T J

    1995-08-01

    To identify the role of endotoxin in grain dust-induced lung disease, we conducted a population-based, cross-sectional investigation among grain handlers and postal workers. The study subjects were selected by randomly sampling all grain facilities and post offices within 100 miles of Iowa City. Our study population consisted of 410 grain workers and 201 postal workers. Grain workers were found to be exposed to higher concentrations of airborne dust (p = 0.0001) and endotoxin (p = 0.0001) when compared with postal workers. Grain workers had a significantly higher prevalence of work-related (cough, phlegm, wheezing, chest tightness, and dyspnea) and chronic (usual cough or phlegm production) respiratory symptoms than postal workers. Moreover, after controlling for age, gender, and cigarette smoking status, work-related respiratory symptoms were strongly associated with the concentration of endotoxin in the bioaerosol in the work setting. The concentration of total dust in the bioaerosol was marginally related to these respiratory problems. After controlling for age, gender, and cigarette smoking status, grain workers were found to have reduced spirometric measures of airflow (FEV1, FEV1/FVC, and FEF25-75) and enhanced airway reactivity to inhaled histamine when compared with postal workers. Although the total dust concentration in the work environment appeared to have little effect on these measures of airflow obstruction, higher concentrations of endotoxin in the bioaerosol were associated with diminished measures of airflow and enhanced bronchial reactivity. Our results indicate that the concentration of endotoxin in the bioaerosol may be particularly important in the development of grain dust-induced lung disease.

  5. Bio-processing of copper from combined smelter dust and flotation concentrate: a comparative study on the stirred tank and airlift reactors.

    Science.gov (United States)

    Vakylabad, Ali Behrad; Schaffie, Mahin; Ranjbar, Mohammad; Manafi, Zahra; Darezereshki, Esmaeel

    2012-11-30

    To scrutinize the influence of the design and type of the bioreactors on the bioleaching efficiency, the bioleaching were evaluated in a batch airlift and a batch stirred tank bioreactors with mixed mesophilic and mixed moderately thermophilic bacteria. According to the results, maximum copper recoveries were achieved using the cultures in the stirred tank bioreactors. It is worth noting that the main phase of the flotation concentrate was chalcopyrite (as a primary sulphide), but the smelter dust mainly contained secondary copper sulphides such as Cu(2)S, CuS, and Cu(5)FeS(4).Under optimum conditions, copper dissolution from the combined flotation concentrate and smelter dust (as an environmental hazard) reached 94.50% in the STR, and 88.02% in the airlift reactor with moderately thermophilic, after 23 days. Also, copper extractions calculated for the bioleaching using mesophilic bacteria were 48.73% and 37.19% in the STR (stirred tank reactor) and the airlift bioreactor, respectively. In addition, the SEM/EDS, XRD, chemical, and mineralogical analyses and studies confirmed the above results. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Dust acoustic solitary and shock excitations in a Thomas-Fermi magnetoplasma

    Energy Technology Data Exchange (ETDEWEB)

    Rahim, Z.; Qamar, A. [Institute of Physics and Electronics, University of Peshawar, Peshawar 25000 (Pakistan); National Center for Physics (NCP) at QAU Campus, Shahdra Valley Road, Islamabad 44000 (Pakistan); Ali, S. [National Center for Physics (NCP) at QAU Campus, Shahdra Valley Road, Islamabad 44000 (Pakistan)

    2014-07-15

    The linear and nonlinear properties of dust-acoustic waves are investigated in a collisionless Thomas-Fermi magnetoplasma, whose constituents are electrons, ions, and negatively charged dust particles. At dust time scale, the electron and ion number densities follow the Thomas-Fermi distribution, whereas the dust component is described by the classical fluid equations. A linear dispersion relation is analyzed to show that the wave frequencies associated with the upper and lower modes are enhanced with the variation of dust concentration. The effect of the latter is seen more strongly on the upper mode as compared to the lower mode. For nonlinear analysis, we obtain magnetized Korteweg-de Vries (KdV) and Zakharov-Kuznetsov (ZK) equations involving the dust-acoustic solitary waves in the framework of reductive perturbation technique. Furthermore, the shock wave excitations are also studied by allowing dissipation effects in the model, leading to the Korteweg-de Vries-Burgers (KdVB) and ZKB equations. The analysis reveals that the dust-acoustic solitary and shock excitations in a Thomas-Fermi plasma are strongly influenced by the plasma parameters, e.g., dust concentration, dust temperature, obliqueness, magnetic field strength, and dust fluid viscosity. The present results should be important for understanding the solitary and shock excitations in the environments of white dwarfs or supernova, where dust particles can exist.

  7. Dust acoustic solitary and shock excitations in a Thomas-Fermi magnetoplasma

    International Nuclear Information System (INIS)

    Rahim, Z.; Qamar, A.; Ali, S.

    2014-01-01

    The linear and nonlinear properties of dust-acoustic waves are investigated in a collisionless Thomas-Fermi magnetoplasma, whose constituents are electrons, ions, and negatively charged dust particles. At dust time scale, the electron and ion number densities follow the Thomas-Fermi distribution, whereas the dust component is described by the classical fluid equations. A linear dispersion relation is analyzed to show that the wave frequencies associated with the upper and lower modes are enhanced with the variation of dust concentration. The effect of the latter is seen more strongly on the upper mode as compared to the lower mode. For nonlinear analysis, we obtain magnetized Korteweg-de Vries (KdV) and Zakharov-Kuznetsov (ZK) equations involving the dust-acoustic solitary waves in the framework of reductive perturbation technique. Furthermore, the shock wave excitations are also studied by allowing dissipation effects in the model, leading to the Korteweg-de Vries-Burgers (KdVB) and ZKB equations. The analysis reveals that the dust-acoustic solitary and shock excitations in a Thomas-Fermi plasma are strongly influenced by the plasma parameters, e.g., dust concentration, dust temperature, obliqueness, magnetic field strength, and dust fluid viscosity. The present results should be important for understanding the solitary and shock excitations in the environments of white dwarfs or supernova, where dust particles can exist

  8. Shifting of Immune Responsiveness to House Dust Mite by Influenza A Infection: Genomic Insights

    KAUST Repository

    Al-Garawi, A.

    2011-12-14

    Respiratory viral infections have been associated with an increased incidence of allergic asthma. However, the mechanisms by which respiratory infections facilitate allergic airway disease are incompletely understood.We previously showed that exposure to a low dose of house dust mite (HDM) resulted in enhanced HDM-mediated allergic airway inflammation, and, importantly, marked airway hyperreactivity only when allergen exposure occurred during an acute influenza A infection. In this study, we evaluated the impact of concurrent influenza infection and allergen exposure at the genomic level, using whole-genome micro-array. Our data showed that, in contrast to exposure to a low dose of HDM, influenza A infection led to a dramatic increase in gene expression, particularly of TLRs, C-type lectin receptors, several complement components, as well as FcεR1. Additionally, we observed increased expression of a number of genes encoding chemokines and cytokines associated with the recruitment of proinflammatory cells. Moreover, HDM exposure in the context of an influenza A infection resulted in the induction of unique genes, including calgranulin A (S100a8), an endogenous damage-associated molecular pattern and TLR4 agonist. In addition, we observed significantly increased expression of serum amyloid A (Saa3) and serine protease inhibitor 3n (Serpina3n). This study showed that influenza infection markedly increased the expression of multiple gene classes capable of sensing allergens and amplifying the ensuing immune-inflammatory response. We propose that influenza A infection primes the lung environment in such a way as to lower the threshold of allergen responsiveness, thus facilitating the emergence of a clinically significant allergic phenotype. Copyright © 2012 by The American Association of Immunologists, Inc.

  9. Occurrence of imidacloprid, carbendazim, and other biocides in Italian house dust: Potential relevance for intakes in children and pets.

    Science.gov (United States)

    Salis, Severyn; Testa, Cecilia; Roncada, Paola; Armorini, Sara; Rubattu, Nicola; Ferrari, Angelo; Miniero, Roberto; Brambilla, Gianfranco

    2017-09-02

    The occurrence of pesticides intended for non-agricultural use was investigated in 206 dust samples drawn from vacuum-cleaner bags from residential flats in Italy. The multi-residue analysis targeted on 95 different active principles was performed with UPLC-MS/MS, with a Limit of Quantification (LOQ) of 0.008 μg/g dry weight. The results indicated the presence of imidacloprid (IMI) and carbendazim (CARB) in 30% and 26% of the samples, with a mean and P95 concentration between 1.6 and 39 and between 0.08 and 4.9 μg/g, respectively. Combined presence of two biocides was noted in 19.4% samples, of three biocides in 9.2% samples, of four biocides in 3.4% samples, and of five and six biocides in 0.5% and 1% samples, respectively. According to the estimated dust intake in infants/toddlers aged 6-24 months (16-100 mg d -1 ) and cats (200 mg d -1 ), it was possible to obtain risk characterization with respect to the Acceptable Daily Intake (ADI) for IMI of 0.060 mg/kg body weight (bw) proposed by the European Food Safety Authority (EFSA) and the chronic Population Adjusted Dose (cPAD) of 0.019 mg/kg bw d -1 by US-EPA. Under the worst-case scenario, the presence of IMI in dust indicates potential exceedance of the cPAD in kittens, to be considered as sentinel also accounting for combined exposure. This study highlights the relevance of consumer empowerment about the responsible use of pesticides as biocidal products in indoor environment.

  10. Application of slightly acidic electrolyzed water for inactivating microbes in a layer breeding house.

    Science.gov (United States)

    Hao, X X; Li, B M; Wang, C Y; Zhang, Q; Cao, W

    2013-10-01

    Lots of microorganisms exist in layer houses can cause bird diseases and worker health concerns. Spraying chemical disinfectants is an effective way to decontaminate pathogenic microorganisms in the air and on surfaces in poultry houses. Slightly acidic electrolyzed water (SAEW, pH 5.0-6.5) is an ideal, environmentally friendly broad-spectrum disinfectant to prevent and control bacterial or viral infection in layer farms. The purpose of this work was to investigate the cleaning effectiveness of SAEW for inactivating the microbes in layer houses. The effect of SAEW was evaluated by solid materials and surface disinfection in a hen house. Results indicate that SAEW with an available chlorine concentration of 250 mg/L, pH value of 6.19, and oxygen reduction potential of 974 mV inactivated 100% of bacteria and fungi in solid materials (dusts, feces, feather, and feed), which is more efficient than common chemical disinfectant such as benzalkonium chloride solution (1:1,000 vol/vol) and povidone-iodine solution (1:1,000 vol/vol). Also, it significantly reduced the microbes on the equipment or facility surfaces (P < 0.05), including floor, wall, feed trough, and water pipe surfaces. Moreover, SAEW effectively decreased the survival rates of Salmonella and Escherichia coli by 21 and 16 percentage points. In addition, spraying the target with tap water before disinfection plays an important role in spray disinfection.

  11. Suspended dust in Norwegian cities

    International Nuclear Information System (INIS)

    2001-01-01

    According to calculations, at least 80 000 people in Oslo and 8 000 in Trondheim were annoyed by too much suspended dust in 2000. The dust concentration is greatest in the spring, presumably because dust is swirling up from melting snow and ice on the streets. Car traffic is the main source of the dust, except for some of the most highly exposed regions where wood-firing from old stoves contributes up to 70 percent of the dust. National targets for air quality include suspended dust, nitrogen dioxide, sulphur dioxide and benzene. Calculations show that nitrogen dioxide emissions exceeding the limit affected 4 000 people in Oslo and 1 000 people in Trondheim. The sulphur dioxide emissions in the major cities did non exceed the national quality limit; they did exceed the limit in some of the smaller industrial centres. In Trondheim, measurements show that the national limit for benzene was exceeded. Most of the emission of nitrogen dioxide comes from the road traffic. Local air pollution at times causes considerable health- and well-being problems in the larger cities and industrial centres, where a great part of the population may be at risk of early death, infection of the respiratory passage, heart- and lung diseases and cancer

  12. Estimation of the in vitro eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust by using reconstituted human corneal epithelium tissue cultures

    DEFF Research Database (Denmark)

    Cao, Yi; Arenholt-Bindslev, Dorthe; Kjærgaard, Søren K

    2015-01-01

    CONTEXT: Eye irritation is a common complaint in indoor environment, but the causes have still not been identified among the multiple exposures in house environments. To identify the potential environmental factors responsible for eye irritation and study the possible mechanisms, an in vitro model...... AND CONCLUSION: LPS and dust showed in vitro eye irritating and inflammatory potential, and cytokines/chemokines like IL-1β and IL-8 may be involved in the mechanisms of eye irritation. The HCE tissue culture may be used as an in vitro model to study environmental exposure induced eye irritation and inflammation....... for eye irritation is suggested. MATERIALS AND METHODS: In this study, reconstituted human corneal epithelium (HCE) tissue cultures were used to study the eye irritating and inflammatory potential of lipopolysaccharide (LPS) and dust. HCE tissue cultures were exposed to a range of concentrations of LPS...

  13. Trace-metal concentrations in African dust: effects of long-distance transport and implications for human health

    Science.gov (United States)

    Garrison, Virginia; Lamothe, Paul; Morman, Suzette; Plumlee, Geoffrey S.; Gilkes, Robert; Prakongkep, Nattaporn

    2010-01-01

    The Sahara and Sahel lose billions of tons of eroded mineral soils annually to the Americas and Caribbean, Europe and Asia via atmospheric transport. African dust was collected from a dust source region (Mali, West Africa) and from downwind sites in the Caribbean [Trinidad-Tobago (TT) and U.S. Virgin Islands (VI)] and analysed for 32 trace-elements. Elemental composition of African dust samples was similar to that of average upper continental crust (UCC), with some enrichment or depletion of specific trace-elements. Pb enrichment was observed only in dust and dry deposition samples from the source region and was most likely from local use of leaded gasoline. Dust particles transported long-distances (VI and TT) exhibited increased enrichment of Mo and minor depletion of other elements relative to source region samples. This suggests that processes occurring during long-distance transport of dust produce enrichment/depletion of specific elements. Bioaccessibility of trace-metals in samples was tested in simulated human fluids (gastric and lung) and was found to be greater in downwind than source region samples, for some metals (e.g., As). The large surface to volume ratio of the dust particles (<2.5 µm) at downwind sites may be a factor.

  14. Dust particle removal efficiency of a venturi scrubber

    International Nuclear Information System (INIS)

    Ali, Majid; Yan, Changqi; Sun, Zhongning; Gu, Haifeng; Mehboob, Khurram

    2013-01-01

    Highlights: ► Experimental and theoretical study of dust removal efficiency in venturi scrubber. ► Dust removal efficiency 99.5% is achieved at throat gas velocity 220 m/s. ► Results obtained from mathematical model concur well with experimental results. - Abstract: The venturi scrubber is one of the most efficient gas cleaning devices to remove the contaminated particles from gaseous stream during severe accident in nuclear power plant. This study is focused on the dust particle removal efficiency of the venturi scrubber experimentally and theoretically. The venturi scrubber encapsulates the dust particles in petite water droplets flowing into it. The water injected into the scrubber is in the form of water film. The study investigates the removal efficiency of venturi scrubber for throat gas velocities of 130, 165 and 200 m/s and liquid flow rates 0.3–1 m 3 /h, whereas dust concentration ranges between 0.1 and 1 g/m 3 . The hydrophobic titanium dioxide (TiO 2 ) particles having density 4.23 g/cm 3 and mean diameter of 1 μm are used as dust particles in this research. Filtration technique is used to measure the concentration of dust particles at inlet and outlet. Experimental results show that the removal efficiency is higher with the increase of throat gas velocity and liquid flow rate. A mathematical model is employed for the verification of experimental results. The model concurs well with the experimental results

  15. Regularities of dust formation during stone cutting for construction works

    Directory of Open Access Journals (Sweden)

    V.G. Lebedev

    2016-09-01

    Full Text Available When cutting stone, a large amount of dust release, which is a mixture of small, mostly sharp, mineral particles. Shallow dry dust with inhalation causes the pathological changes in organs that are a consequence of infiltration of acute and solids particles. Despite the importance of this problem, the questions of dust generation during the various working processes and its fractions distribution are practically not considered. This determines the time of dust standing in the air and its negative impact on a person. Aim: The aim of this research is to study the process of dusting during stones cutting and dust distribution on fractions regularities and quantification of dust formation process in order to improve the production equipment, staff individual and collective safety equipment. Materials and Methods: Many types of cutting can be divided into two types - a “dry” cutting and cutting with fluid. During “dry” cutting a dust represents a set of micro-chips which are cut off by the abrasive grains. The size of such chips very small: from a micrometer to a few micrometers fraction. Thus, the size of chips causes the possibility of creating dust slurry with low fall velocity, and which is located in the working space in large concentrations. Results: The following characteristic dependences were obtained as a result of research: dependence of the dust fall from the size of the dust particles, size of dust particles from minute feeding and grain range wheel, the specific amount of dust from the number of grit abrasive wheel and the temperature of the dust particles from the feeding at wheel turnover. It was shown that the distribution of chips (dust by size will request of a normal distribution low. Dimensions of chips during cut are in the range of 0.4...6 μm. Thus, dust slurry is formed with time of particles fall of several hours. This creates considerable minute dust concentration - within 0.28∙10^8...1.68∙10^8 units/m3.

  16. Simulating indoor concentrations of NO(2) and PM(2.5) in multifamily housing for use in health-based intervention modeling.

    Science.gov (United States)

    Fabian, P; Adamkiewicz, G; Levy, J I

    2012-02-01

    Residents of low-income multifamily housing can have elevated exposures to multiple environmental pollutants known to influence asthma. Simulation models can characterize the health implications of changing indoor concentrations, but quantifying the influence of interventions on concentrations is challenging given complex airflow and source characteristics. In this study, we simulated concentrations in a prototype multifamily building using CONTAM, a multizone airflow and contaminant transport program. Contaminants modeled included PM(2.5) and NO(2) , and parameters included stove use, presence and operability of exhaust fans, smoking, unit level, and building leakiness. We developed regression models to explain variability in CONTAM outputs for individual sources, in a manner that could be utilized in simulation modeling of health outcomes. To evaluate our models, we generated a database of 1000 simulated households with characteristics consistent with Boston public housing developments and residents and compared the predicted levels of NO(2) and PM(2.5) and their correlates with the literature. Our analyses demonstrated that CONTAM outputs could be readily explained by available parameters (R(2) between 0.89 and 0.98 across models), but that one-compartment box models would mischaracterize concentrations and source contributions. Our study quantifies the key drivers for indoor concentrations in multifamily housing and helps to identify opportunities for interventions. Many low-income urban asthmatics live in multifamily housing that may be amenable to ventilation-related interventions such as weatherization or air sealing, wall and ceiling hole repairs, and exhaust fan installation or repair, but such interventions must be designed carefully given their cost and their offsetting effects on energy savings as well as indoor and outdoor pollutants. We developed models to take into account the complex behavior of airflow patterns in multifamily buildings, which can

  17. Concentration of urine from fatteners combined with ammonia removal by scrubbing exhaust air of a pig house

    NARCIS (Netherlands)

    Willers, H.C.; Melse, R.W.; Ogink, N.W.M.

    2003-01-01

    In the Dutch Hercules project feces and urine from pigs are collected separately and treated in two processes: feces are composted and urine is concentrated by water evaporation. Water unsaturated exhaust air from the pig house is used for evaporation in a packed bed scrubber. The urine is acidified

  18. Can We Trust Real Time Measurements of Lung Deposited Surface Area Concentrations in Dust from Powder Nanomaterials?

    DEFF Research Database (Denmark)

    Levin, Marcus; Witschger, Olivier; Bau, Sebastien

    2016-01-01

    A comparison between various methods for real-time measurements of lung deposited surface area (LDSA) using spherical particles and powder dust with specific surface area ranging from 0.03 to 112 m2 g-1 was conducted. LDSA concentrations measured directly using Nanoparticle Surface Area Monitor...... gravimetrical filter measurements and specific surface areas. Measurement of LDSA showed very good correlation in measurements of spherical particles (R2 > 0.97, Ratio 1.0 to 1.04). High surface area nanomaterial powders showed a fairly reliable correlation between NSAM and Aerotrak (R2 0...... present. We conclude that there is currently insufficient reliability and comparability between methods in the measurement of LDSA concentrations. Further development is required to enable use of LDSA for reliable dose metric and regulatory enforcement of exposure....

  19. DUST-BATHING BEHAVIORS OF AFRICAN HERBIVORES AND THE POTENTIAL RISK OF INHALATIONAL ANTHRAX.

    Science.gov (United States)

    Barandongo, Zoe R; Mfune, John K E; Turner, Wendy C

    2018-01-01

    :  Anthrax in herbivorous wildlife and livestock is generally assumed to be transmitted via ingestion or inhalation of Bacillus anthracis spores. Although recent studies have highlighted the importance of the ingestion route for anthrax transmission, little is known about the inhalational route in natural systems. Dust bathing could aerosolize soilborne pathogens such as B. anthracis, exposing dust-bathing individuals to inhalational infections. We investigated the potential role of dust bathing in the transmission of inhalational anthrax to herbivorous wildlife in Etosha National Park, Namibia, an area with endemic seasonal anthrax outbreaks. We 1) cultured soils from dust-bathing sites for the presence and concentration of B. anthracis spores, 2) monitored anthrax carcass sites, the locations with the highest B. anthracis concentrations, for evidence of dust bathing, including a site where a zebra died of anthrax on a large dust bath, and 3) characterized the ecology and seasonality of dust bathing in plains zebra ( Equus quagga), blue wildebeest ( Connochaetes taurinus), and African savanna elephant ( Loxodonta africana) using a combination of motion-sensing camera traps and direct observations. Only two out of 83 dust-bath soils were positive for B. anthracis, both with low spore concentrations (≤20 colony-forming units per gram). We also detected no evidence of dust baths occurring at anthrax carcass sites, perhaps due to carcass-induced changes in soil composition that may deter dust bathing. Finally, despite observing some seasonal variation in dust bathing, preliminary evidence suggests that the seasonality of dust bathing and anthrax mortalities are not correlated. Thus, although dust bathing creates a dramatic cloud of aerosolized soil around an individual, our microbiologic, ecologic, and behavioral results in concert demonstrate that dust bathing is highly unlikely to transmit inhalational anthrax infections.

  20. Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section.

    Science.gov (United States)

    Patts, Justin R; Barone, Teresa L

    2017-05-01

    Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may

  1. 30 CFR 71.100 - Respirable dust standard.

    Science.gov (United States)

    2010-07-01

    ... concentration of respirable dust in the mine atmosphere during each shift to which each miner in the active... shall be measured with an approved sampling device and expressed in terms of an equivalent concentration determined in accordance with § 71.206 (Approved sampling devices; equivalent concentrations). ...

  2. Peak nasal inspiratory flow as outcome for provocation studies in allergen exposure chambers

    DEFF Research Database (Denmark)

    Boelke, Georg; Berger, Uwe; Bergmann, Karl-Christian

    2017-01-01

    : In a randomized controlled blinded setting subjects suffering from allergic rhinitis were exposed to grass pollen, birch pollen, house dust mite and/or placebo in the GA(2)LEN chamber. Different allergen concentrations were used to evaluate symptom severities. Patients had to perform PNIF before and every 30 min...... during a challenge using a portable PNIF meter. RESULTS: 86 subjects participated in 203 challenges, altogether. House dust mite provocations caused the greatest reduction in PNIF values, followed by grass pollen and birch pollen. Provocations with every allergen or pollen concentration led...... symptoms. CONCLUSION: PNIF is a helpful and feasible tool for conducting provocation trials with allergens, especially grass pollen and house dust mite, in an AEC....

  3. Respirable dust measured downwind during rock dust application.

    Science.gov (United States)

    Harris, M L; Organiscak, J; Klima, S; Perera, I E

    2017-05-01

    The Pittsburgh Mining Research Division of the U.S. National Institute for Occupational Safety and Health (NIOSH) conducted underground evaluations in an attempt to quantify respirable rock dust generation when using untreated rock dust and rock dust treated with an anticaking additive. Using personal dust monitors, these evaluations measured respirable rock dust levels arising from a flinger-type application of rock dust on rib and roof surfaces. Rock dust with a majority of the respirable component removed was also applied in NIOSH's Bruceton Experimental Mine using a bantam duster. The respirable dust measurements obtained downwind from both of these tests are presented and discussed. This testing did not measure miners' exposure to respirable coal mine dust under acceptable mining practices, but indicates the need for effective continuous administrative controls to be exercised when rock dusting to minimize the measured amount of rock dust in the sampling device.

  4. Endotoxins in indoor air and settled dust in primary schools in a subtropical climate.

    Science.gov (United States)

    Salonen, Heidi; Duchaine, Caroline; Létourneau, Valérie; Mazaheri, Mandana; Clifford, Sam; Morawska, Lidia

    2013-09-03

    Endotoxins can significantly affect the air quality in school environments. However, there is currently no reliable method for the measurement of endotoxins, and there is a lack of reference values for endotoxin concentrations to aid in the interpretation of measurement results in school settings. We benchmarked the "baseline" range of endotoxin concentration in indoor air, together with endotoxin load in floor dust, and evaluated the correlation between endotoxin levels in indoor air and settled dust, as well as the effects of temperature and humidity on these levels in subtropical school settings. Bayesian hierarchical modeling indicated that the concentration in indoor air and the load in floor dust were generally (EU/m(3) and EU/m(2), respectively. Exceeding these levels would indicate abnormal sources of endotoxins in the school environment and the need for further investigation. Metaregression indicated no relationship between endotoxin concentration and load, which points to the necessity for measuring endotoxin levels in both the air and settled dust. Temperature increases were associated with lower concentrations in indoor air and higher loads in floor dust. Higher levels of humidity may be associated with lower airborne endotoxin concentrations.

  5. Influence of fly dust from coking plants on some biological processes of plants

    Energy Technology Data Exchange (ETDEWEB)

    Masek, V

    1972-03-01

    The influence of three typical samples of fly dust from a coking plant on enzymatic reactions, photosynthesis, chlorophyll concentration in leaves of bean plants was studied. The hydrolysis of starch with amylases and of the albumen with pepsin at 37 C and the inversion of sacharosis by invertase in a buffered environment were also examined. None of the three dust samples had a significant effect on enzymatic reactions. Applying the dust samples to the leaves of young bean plants reduced the intensity of photosynthesis and chlorophyll concentration. In aqueous extracts, the dust samples liberated only small quantities of nutrients, plants which were grown in a dust suspension showed no increase of dry substance and growth rate. A stimulating effect of the dust samples on root growth was determined. Mixing the dust samples with the soil influenced the accessibility of water to plants. 17 references, 6 figures, 9 tables.

  6. Influenza A facilitates sensitization to house dust mite in infant mice leading to an asthma phenotype in adulthood

    KAUST Repository

    Al-Garawi, A

    2011-08-31

    The origins of allergic asthma, particularly in infancy, remain obscure. Respiratory viral infections and allergen sensitization in early life have been associated with asthma in young children. However, a causal link has not been established. We investigated whether an influenza A infection in early life alters immune responses to house dust mite (HDM) and promotes an asthmatic phenotype later in life. Neonatal (8-day-old) mice were infected with influenza virus and 7 days later, exposed to HDM for 3 weeks. Unlike adults, neonatal mice exposed to HDM exhibited negligible immune responsiveness to HDM, but not to influenza A. HDM responsiveness in adults was associated with distinct Ly6c + CD11b + inflammatory dendritic cell and CD8α + plasmacytoid (pDC) populations that were absent in HDM-exposed infant mice, suggesting an important role in HDM-mediated inflammation. Remarkably, HDM hyporesponsiveness was overcome when exposure occurred concurrently with an acute influenza infection; young mice now displayed robust allergen-specific immunity, allergic inflammation, and lung remodeling. Remodeling persisted into early adulthood, even after prolonged discontinuation of allergen exposure and was associated with marked impairment of lung function. Our data demonstrate that allergen exposure coincident with acute viral infection in early life subverts constitutive allergen hyporesponsiveness and imprints an asthmatic phenotype in adulthood.

  7. House dust mite (Der p 10) and crustacean allergic patients may react to food containing Yellow mealworm proteins.

    Science.gov (United States)

    Verhoeckx, Kitty C M; van Broekhoven, Sarah; den Hartog-Jager, Constance F; Gaspari, Marco; de Jong, Govardus A H; Wichers, Harry J; van Hoffen, Els; Houben, Geert F; Knulst, André C

    2014-03-01

    Due to the imminent growth of the world population, shortage of protein sources for human consumption will arise in the near future. Alternative and sustainable protein sources (e.g. insects) are being explored for the production of food and feed. In this project, the safety of Yellow mealworms (Tenebrio molitor L.) for human consumption was tested using approaches as advised by the European Food Safety Authority for allergenicity risk assessment. Different Yellow mealworm protein fractions were prepared, characterised, and tested for cross-reactivity using sera from patients with an inhalation or food allergy to biologically related species (House dust mite (HDM) and crustaceans) by immunoblotting and basophil activation. Furthermore, the stability was investigated using an in vitro pepsin digestion test. IgE from HDM- and crustacean allergic patients cross-reacted with Yellow mealworm proteins. This cross-reactivity was functional, as shown by the induction of basophil activation. The major cross-reactive proteins were identified as tropomyosin and arginine kinase, which are well known allergens in arthropods. These proteins were moderately stable in the pepsin stability test. Based on these cross-reactivity studies, there is a realistic possibility that HDM- and crustacean allergic patients may react to food containing Yellow mealworm proteins. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Linkages between observed, modeled Saharan dust loading and meningitis in Senegal during 2012 and 2013

    Science.gov (United States)

    Diokhane, Aminata Mbow; Jenkins, Gregory S.; Manga, Noel; Drame, Mamadou S.; Mbodji, Boubacar

    2016-04-01

    The Sahara desert transports large quantities of dust over the Sahelian region during the Northern Hemisphere winter and spring seasons (December-April). In episodic events, high dust concentrations are found at the surface, negatively impacting respiratory health. Bacterial meningitis in particular is known to affect populations that live in the Sahelian zones, which is otherwise known as the meningitis belt. During the winter and spring of 2012, suspected meningitis cases (SMCs) were with three times higher than in 2013. We show higher surface particular matter concentrations at Dakar, Senegal and elevated atmospheric dust loading in Senegal for the period of 1 January-31 May during 2012 relative to 2013. We analyze simulated particulate matter over Senegal from the Weather Research and Forecasting (WRF) model during 2012 and 2013. The results show higher simulated dust concentrations during the winter season of 2012 for Senegal. The WRF model correctly captures the large dust events from 1 January-31 March but has shown less skill during April and May for simulated dust concentrations. The results also show that the boundary conditions are the key feature for correctly simulating large dust events and initial conditions are less important.

  9. Measurements of radon concentrations in a sample representative of housing in Franche-Comte

    International Nuclear Information System (INIS)

    Aury, K.; Clinard, F.; Tillier, C.; Catelinois, O.; Pirard, P.; Aury, K.; Nourry, L.; Hochart, A.

    2008-01-01

    Three departments on four ones in Franche-Comte are classified at risk for radon: measurements are so compulsory in establishments receiving public. For the residential sector, no obligation of measurement are compulsory when french people spend 70% of their time in it. The data concerning homes are fragmentary and deserve to be completed. This campaign of measurements has confirmed the existence of radon in relatively high concentrations in Franche-Comte, including the sedimentary areas, justifying the necessity to realize a precise evaluation of the sanitary impact. The model will allow to study different strategies to reduce radon in houses. (N.C.)

  10. House dust mite allergen causes certain features of steroid resistant asthma in high fat fed obese mice.

    Science.gov (United States)

    Singh, Vijay Pal; Mabalirajan, Ulaganathan; Pratap, Kunal; Bahal, Devika; Maheswari, Deepanshu; Gheware, Atish; Bajaj, Aabha; Panda, Lipsa; Jaiswal, Ashish; Ram, Arjun; Agrawal, Anurag

    2018-02-01

    Obesity is a high risk factor for diseases such as cardiovascular, metabolic syndrome and asthma. Obese-asthma is another emerging phenotype in asthma which is typically refractive to steroid treatment due to its non-classical features such as non-eosinophilic cellular inflammation. The overall increased morbidity, mortality and economical burden in asthma is mainly due to steroid resistant asthma. In the present study, we used high fat diet induced obese mice which when sensitized with house dust mite (HDM) showed steroid resistant features. While the steroid, dexamethasone (DEX), treatment to high fat fed naïve mice could not reduce the airway hyperresponsiveness (AHR) induced by high fat, DEX treatment to high fat fed allergic mice could not reduce the HDM allergen induced airway remodeling features though it reduced airway inflammation. Further, these HDM induced high fat fed mice with or without DEX treatment had shown the increased activity and expression of arginase as well as the inducible nitric oxide synthase (iNOS) expression. However, DEX treatment had reduced the expressions of high iNOS and arginase I in control chow diet fed mice. Thus, we speculate that the steroid resistance seen in human obese asthmatics could be stemming from altered NO metabolism and its induced airway remodeling and with further investigations, it would encourage new treatments specific to obese-asthma phenotype. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Measurement of IgG antibodies to house dust mite and grass pollen by a solid-phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Delespesse, G; Debisschop, M J; Flament, J [Hopital Saint Pierre, Louvain (Belgium). Lab. de Recherches de la Clinique Medicale

    1979-09-01

    A solid-phase radioimmunoassay was used to measure specific IgG antibodies to either Dermatophagoides pteronyssinus (DPT) or grass pollens. Radiolabelled protein A from Staphylococcus aureus (SpA) was used to determine the IgG antibodies attached to the microtubes. The binding of IgG from either normal or allergic sera to DPT-coated tubes was antigen specific and mediated by the Fab fragment of the immunoglobulin. IgG antibodies from non-allergic serum competed with IgE antibodies to DPT. IgE antibodies did not significantly interfere with the assay. Indeed heating a reaginic serum resulted in a striking reduction of the (/sup 125/I) anti- IgE binding to allergen-coated tubes without modifying the (/sup 125/I)-SpA binding. Furthermore, filtration of a reaginic serum through Sephacryl S-200 separated a peak of IgE antibodies. The solid phase method was more sensitive than a double-antibody technique employing the same DPT extract as labelled antigen. Non-allergic subjects had less IgG antibodies to DPT or grass pollens than allergic patients. In untreated patients, there was a good correlation between levels of IgG and IgE antibodies to grass pollens but not to DPT. Patients hyposensitized to house dust mite had on the average three times more specific IgG antibodies than untreated cases. (author).

  12. Measurement of IgG antibodies to house dust mite and grass pollen by a solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Delespesse, G.; Debisschop, M.J.; Flament, J.

    1979-01-01

    A solid-phase radioimmunoassay was used to measure specific IgG antibodies to either Dermatophagoides pteronyssinus (DPT) or grass pollens. Radiolabelled protein A from Staphylococcus aureus (SpA) was used to determine the IgG antibodies attached to the microtubes. The binding of IgG from either normal or allergic sera to DPT-coated tubes was antigen specific and mediated by the Fab fragment of the immunoglobulin. IgG antibodies from non-allergic serum competed with IgE antibodies to DPT. IgE antibodies did not significantly interfere with the assay. Indeed heating a reaginic serum resulted in a striking reduction of the ( 125 I) anti- IgE binding to allergen-coated tubes without modifying the ( 125 I)-SpA binding. Furthermore, filtration of a reaginic serum through Sephacryl S-200 separated a peak of IgE antibodies. The solid phase method was more sensitive than a double-antibody technique employing the same DPT extract as labelled antigen. Non-allergic subjects had less IgG antibodies to DPT or grass pollens than allergic patients. In untreated patients, there was a good correlation between levels of IgG and IgE antibodies to grass pollens but not to DPT. Patients hyposensitized to house dust mite had on the average three times more specific IgG antibodies than untreated cases. (author)

  13. THE MEASUREMENT AND DISTRIBUTION OF WOOD DUST

    Directory of Open Access Journals (Sweden)

    Andrea Rosario Proto

    2010-03-01

    Full Text Available In Italy, the woodworking industry presents many issues in terms of occupational health and safety. This study on exposure to wood dust could contribute to the realization of a prevention model in order to limit exposure to carcinogenic agents to the worker. The sampling methodology illustrated the analysis of dust emissions from the woodworking machinery in operation throughout the various processing cycles. The quantitative and qualitative assessment of exposure was performed using two different methodologies. The levels of wood dust were determined according to EN indications and sampling was conducted using IOM and Cyclon personal samplers. The qualitative research of wood dust was performed using an advanced laser air particle counter. This allowed the number of particles present to be counted in real time. The results obtained allowed for an accurate assessment of the quality of the dust emitted inside the workplace during the various processing phases. The study highlighted the distribution of air particles within the different size classes, the exact number of both thin and ultra-thin dusts, and confirmed the high concentration of thin dust particles which can be very harmful to humans.

  14. Interannual Variability in Dust Deposition, Radiative Forcing, and Snowmelt Rates in the Colorado River Basin

    Science.gov (United States)

    Skiles, M.; Painter, T. H.; Deems, J. S.; Barrett, A. P.

    2011-12-01

    Dust in snow accelerates snowmelt through its direct reduction of albedo and its further reduction of albedo by accelerating the growth of snow effective grain size. Since the Anglo expansion and disturbance of the western US that began in the mid 19th century, the mountain snow cover of the Colorado River Basin has been subject to five-fold greater dust loading. Here we present the impacts of dust deposition onto alpine snow cover using a 7-year energy balance record at the alpine and subalpine towers in the Senator Beck Basin Study Area (SBBSA), San Juan Mountains in southwestern Colorado, USA. We assess the radiative and hydrologic impacts with a two-layer point snow energy balance snowmelt model that calculates snowmelt and predicts point runoff using measured inputs of energy exchanges and snow properties. By removing the radiative forcing due to dust, we can determine snowmelt under observed dusty and modeled clean conditions. Additionally, we model the relative response of melt rates to simulated increases in air temperature. Our modeling results indicate that the number of days that dust advances retreat of snow cover and cumulative radiative forcing are linearly related to total dust concentration. The greatest dust radiative impact occurred in 2009, when the highest observed end of year dust concentrations reduced visible albedo to less than 0.35 during the last three weeks of snowcover and snow cover duration was shortened by 50 days. This work also shows that dust radiative forcing has a markedly greater impact on snow cover duration than increases in temperature in terms of acceleration of snowmelt. We have completed the same analysis over a 2-year energy balance record at the Grand Mesa Study plot (GMSP) in west central Colorado, 150 km north of SBBSA. This new location allows us to assess site variability. For example, at SBBSA 2010 and 2011 were the second and third highest dust deposition years, respectively, but 2010 was a larger year with 3

  15. Raw Cow’s Milk Prevents the Development of Airway Inflammation in a Murine House Dust Mite-Induced Asthma Model

    Directory of Open Access Journals (Sweden)

    Suzanne Abbring

    2017-08-01

    Full Text Available Epidemiological studies show an inverse relation between raw cow’s milk consumption and the development of asthma. This protective effect seems to be abolished by milk processing. However, evidence for a causal relationship is lacking, and direct comparisons between raw and processed milk are hardly studied. Therefore, this study investigated the preventive capacity of raw and heated raw milk on the development of house dust mite (HDM-induced allergic asthma in mice. Six- to seven-week-old male BALB/c mice were intranasally (i.n. sensitized with 1 µg HDM or PBS on day 0, followed by an i.n. challenge with 10 µg HDM or PBS on days 7–11. In addition, mice were fed 0.5 mL raw cow’s milk, heated raw cow’s milk, or PBS three times a week throughout the study, starting 1 day before sensitization. On day 14, airway hyperresponsiveness (AHR in response to increasing doses of methacholine was measured to assess lung function. Bronchoalveolar lavage fluid (BALF and lungs were furthermore collected to study the extent of airway inflammation. Raw milk prevented both HDM-induced AHR and pulmonary eosinophilic inflammation, whereas heated raw milk did not. Both milk types suppressed the Th2-polarizing chemokine CCL17 in lung homogenates and reduced lung Th2 and Th17 cell frequency. IL-4 and IL-13 production after ex vivo restimulation of lung T cells with HDM was also reduced by both milk types. However, local IL-5 and IL-13 concentrations were only suppressed by raw milk. These findings support the asthma-protective capacity of raw cow’s milk and show the importance of reduced local type 2 cytokine levels. Heated raw milk did not show an asthma-protective effect, which indicates the involvement of heat-sensitive components. Besides causal evidence, this study provides the basis for further mechanistic studies.

  16. Characterization of atmospheric bioaerosols along the transport pathway of Asian dust during the Dust-Bioaerosol 2016 Campaign

    Science.gov (United States)

    Tang, Kai; Huang, Zhongwei; Huang, Jianping; Maki, Teruya; Zhang, Shuang; Shimizu, Atsushi; Ma, Xiaojun; Shi, Jinsen; Bi, Jianrong; Zhou, Tian; Wang, Guoyin; Zhang, Lei

    2018-05-01

    Previous studies have shown that bioaerosols are injected into the atmosphere during dust events. These bioaerosols may affect leeward ecosystems, human health, and agricultural productivity and may even induce climate change. However, bioaerosol dynamics have rarely been investigated along the transport pathway of Asian dust, especially in China where dust events affect huge areas and massive numbers of people. Given this situation, the Dust-Bioaerosol (DuBi) Campaign was carried out over northern China, and the effects of dust events on the amount and diversity of bioaerosols were investigated. The results indicate that the number of bacteria showed remarkable increases during the dust events, and the diversity of the bacterial communities also increased significantly, as determined by means of microscopic observations with 4,6-diamidino-2-phenylindole (DAPI) staining and MiSeq sequencing analysis. These results indicate that dust clouds can carry many bacteria of various types into downwind regions and may have potentially important impacts on ecological environments and climate change. The abundances of DAPI-stained bacteria in the dust samples were 1 to 2 orders of magnitude greater than those in the non-dust samples and reached 105-106 particles m-3. Moreover, the concentration ratios of DAPI-stained bacteria to yellow fluorescent particles increased from 5.1 % ± 6.3 % (non-dust samples) to 9.8 % ± 6.3 % (dust samples). A beta diversity analysis of the bacterial communities demonstrated the distinct clustering of separate prokaryotic communities in the dust and non-dust samples. Actinobacteria, Bacteroidetes, and Proteobacteria remained the dominant phyla in all samples. As for Erenhot, the relative abundances of Acidobacteria and Chloroflexi had a remarkable rise in dust events. In contrast, the relative abundances of Acidobacteria and Chloroflexi in non-dust samples of R-DzToUb were greater than those in dust samples. Alphaproteobacteria made the major

  17. Carpet-dust chemicals as measures of exposure: Implications of variability

    Directory of Open Access Journals (Sweden)

    Whitehead Todd P

    2012-03-01

    Full Text Available Abstract Background There is increasing interest in using chemicals measured in carpet dust as indicators of chemical exposures. However, investigators have rarely sampled dust repeatedly from the same households and therefore little is known about the variability of chemical levels that exist within and between households in dust samples. Results We analyzed 9 polycyclic aromatic hydrocarbons, 6 polychlorinated biphenyls, and nicotine in 68 carpet-dust samples from 21 households in agricultural communities of Fresno County, California collected from 2003-2005. Chemical concentrations (ng per g dust ranged from Conclusions Our findings suggest that attenuation bias should be relatively modest when using these semi-volatile carpet-dust chemicals as exposure surrogates in epidemiologic studies.

  18. Mechanisms of metal dusting corrosion

    DEFF Research Database (Denmark)

    Hummelshøj, Thomas Strabo

    In this thesis the early stages of metal dusting corrosion is addressed; the development of carbon expanded austenite, C, and the decomposition hereof into carbides. Later stages of metal dusting corrosion are explored by a systematic study of stainless steel foils exposed to metal dusting...... deformed stainless steel flakes is transformed to expanded martensite/austenite during low-temperature carburization. Various experimental procedures to experimentally determine the concentration dependent diffusion coefficient of carbon in expanded austenite are evaluated. The most promising procedure...... powders and flakes. The nature of the decomposition products, carbides of the form M23C6 and M7C3, were evaluated by X-ray diffraction, light optical microscopy, scanning electron microscopy and thermodynamic modelling. The decomposition was found to be dependent on several parameters such as thermal...

  19. Pulmonary Toxicity Studies of Lunar Dust in Rodents

    Science.gov (United States)

    Lam, Chiu-Wing; James, John T.

    2012-01-01

    NASA has been contemplating returning astronauts to the moon for long-duration habitation and research and using it as a stepping-stone to Mars. Other spacefaring nations are planning to send humans to the moon for the first time. The surface of the moon is covered by a layer of fine dust. Fine terrestrial dusts, if inhaled, are known to pose a health risk to humans. Some Apollo crews briefly exposed to moon dust that adhered to spacesuits and became airborne in the Lunar Module reported eye and throat irritation. The habitable area of any lunar landing vehicle or outpost would inevitably become contaminated with lunar dust. To assess the health risks of exposure of humans to airborne lunar dust, we evaluated the toxicity of Apollo 14 moon dust in animal lungs. Studies of the pulmonary toxicity of a dust are generally first done by intratracheal instillation (ITI) of aqueous suspensions of the test dust into the lungs of rodents. If a test dust is irritating or cytotoxic to the lungs, the alveolar macrophages, after phagocytizing the dust particles, will release cellular messengers to recruit white blood cells (WBCs) and to induce dilation of blood capillary walls to make them porous, allowing the WBCs to gain access to the alveolar space. The dilation of capillary walls also allows serum proteins and water entering the lung. Besides altering capillary integrity, a toxic dust can also directly kill the cells that come into contact with it or ingest it, after which the dead cells would release their contents, including lactate dehydrogenase (a common enzyme marker of cell death or tissue damage). In the treated animals, we lavaged the lungs 1 and 4 weeks after the dust instillation and measured the concentrations of these biomarkers of toxicity in the bronchioalveolar lavage fluids to determine the toxicity of the dust. To assess whether the inflammation and cellular injury observed in the biomarker study would lead to persistent or progressive histopathological

  20. Fully kinetic simulation of ion acoustic and dust-ion acoustic waves

    International Nuclear Information System (INIS)

    Hosseini Jenab, S. M.; Kourakis, I.; Abbasi, H.

    2011-01-01

    A series of numerical simulations is presented, based on a recurrence-free Vlasov kinetic model using kinetic phase point trajectories. All plasma components are modeled kinetically via a Vlasov evolution equation, then coupled through Poisson's equation. The dynamics of ion acoustic waves in an electron-ion and in a dusty (electron-ion-dust) plasma configuration are investigated, focusing on wave decay due to Landau damping and, in particular, on the parametric dependence of the damping rate on the dust concentration and on the electron-to-ion temperature ratio. In the absence of dust, the occurrence of damping was observed, as expected, and its dependence to the relative magnitude of the electron vs ion temperature(s) was investigated. When present, the dust component influences the charge balance, enabling dust-ion acoustic waves to survive Landau damping even in the extreme regime where T e ≅ T i . The Landau damping rate is shown to be minimized for a strong dust concentration or/and for a high value of the electron-to-ion temperature ratio. Our results confirm earlier theoretical considerations and contribute to the interpretation of experimental observations of dust-ion acoustic wave characteristics.

  1. Implementation of dust emission and chemistry into the Community Multiscale Air Quality modeling system and initial application to an Asian dust storm episode

    Directory of Open Access Journals (Sweden)

    K. Wang

    2012-11-01

    Full Text Available The US Environmental Protection Agency's (EPA Community Multiscale Air Quality (CMAQ modeling system version 4.7 is further developed to enhance its capability in simulating the photochemical cycles in the presence of dust particles. The new model treatments implemented in CMAQ v4.7 in this work include two online dust emission schemes (i.e., the Zender and Westphal schemes, nine dust-related heterogeneous reactions, an updated aerosol inorganic thermodynamic module ISORROPIA II with an explicit treatment of crustal species, and the interface between ISORROPIA II and the new dust treatments. The resulting improved CMAQ (referred to as CMAQ-Dust, offline-coupled with the Weather Research and Forecast model (WRF, is applied to the April 2001 dust storm episode over the trans-Pacific domain to examine the impact of new model treatments and understand associated uncertainties. WRF/CMAQ-Dust produces reasonable spatial distribution of dust emissions and captures the dust outbreak events, with the total dust emissions of ~111 and 223 Tg when using the Zender scheme with an erodible fraction of 0.5 and 1.0, respectively. The model system can reproduce well observed meteorological and chemical concentrations, with significant improvements for suspended particulate matter (PM, PM with aerodynamic diameter of 10 μm, and aerosol optical depth than the default CMAQ v4.7. The sensitivity studies show that the inclusion of crustal species reduces the concentration of PM with aerodynamic diameter of 2.5 μm (PM2.5 over polluted areas. The heterogeneous chemistry occurring on dust particles acts as a sink for some species (e.g., as a lower limit estimate, reducing O3 by up to 3.8 ppb (~9% and SO2 by up to 0.3 ppb (~27% and as a source for some others (e.g., increasing fine-mode SO42− by up to 1.1 μg m−3 (~12% and PM2.5 by up to 1.4 μg m−3 (~3% over the domain. The

  2. Analysis of Dust and Fission Products in PBMR Turbine

    International Nuclear Information System (INIS)

    Stempniewicz, M.M.; Wessels, D.

    2014-01-01

    A 400 MWth direct cycle Pebble Bed Modular reactor was under development in South Africa. The work performed included design and safety analyses. In HTR/PBMR, graphite dust is generated during normal reactor operation due to pebble-to-pebble scratching. This dust will be deposited throughout the primary system. Furthermore, the dust will become radioactive due to sorption of fission products released, although in very small quantities, during normal operation. This paper presents a model and analyses of the PBMR turbine with the SPECTRA code. The purpose of the present work was to estimate the amount and distribution of deposited dust and the fission products, namely cesium, iodine, and silver, during plant life-time, which was assumed to be 40 full-power years. The performed work showed that after 40 years of plant life-time deposited layers are very small. The largest deposition is of course observed on the dust filters. Apart from the dust filters, the largest dust deposition is observed on the: • Outer Casing (inner walls) • Turbine Rotor Cooling Cavity (inner walls) • HPC Cold Cooling Gas Header (inner walls) This is caused by relatively low gas velocities in these volumes. The low velocities allow a continuous build-up of the dust layer. About 90% of cesium, 40% of iodine, and 99.9% of silver is adsorbed on the metallic structures of the turbine. The sorption rate increases along the turbine due to decreasing temperatures. In case of cesium and iodine the highest concentrations are observed in the last stage (stage 12) of the turbine. In the case of silver the sorption is so large that the silver vapor is significantly depleted in the last stages of the turbine. This is a reason for having a maximum in silver concentration in the stage 10. In the following stages the concentration decreases due to very small silver vapor fraction in the gas. (author)

  3. Exposure assessment of lead from food and airborne dusts and biomonitoring in pregnant mothers, their fetus and siblings in Karachi, Pakistan and Shimotsuke, Japan.

    Science.gov (United States)

    Kayama, Fujio; Fatmi, Zafar; Ikegami, Akihiko; Mizuno, Atsuko; Ohtsu, Mayumi; Mise, Nathern; Cui, Xiaoyi; Ogawa, Masanori; Sakamoto, Takako; Nakagi, Yoshiko; Yoshida, Takahiko; Sahito, Ambreen; Naeem, Shahla; Ghias, Kulsoom; Zuberi, Hina; Tariq, Kanwal; Kobayashi, Yayoi; Nohara, Keiko

    2016-03-01

    Exposure assessment of lead (Pb) and Arsenic (As) from food, water, and house dust intake were assessed among pregnant women, their children and fetuses in Pakistan and Japan, as well as their body burden of the metals in their blood. Fifty families which included a pregnant woman, a fetus and the 1-3-year-old siblings were recruited in Karachi and Khairpur in Pakistan, and Shimotsuke and Asahikawa in Japan, respectively. Their dietary exposure to Pb and As was measured in 3-day food duplicates and drinking water by ICP-MP. Pb in house dust and respirable dust was evaluated with an energy dispersive X-ray fluorescence spectrometry. Non-radioactive isotope Pb profiles of blood specimens will be compared with those of the exposure origins, such as food duplicates, respirable house dust, the soils nearby, and gasoline. Judging from the data collected and analyzed so far, contribution from dietary intake is highly correlated to higher body burden of Pb among Pakistani mothers. Additional data analyses will reveal the status of Pb and As body burden in Pakistani mothers, fetuses and their siblings, and causal sources of high body burden is delineated by Pb isotope profile analysis of different sources of Pb exposure.

  4. Endotoxin, Coliform, and Dust Levels in Various Types of Rodent Bedding

    OpenAIRE

    Whiteside, Tanya E; Thigpen, Julius E; Kissling, Grace E; Grant, Mary G; Forsythe, Diane B

    2010-01-01

    Endotoxins in grain dust, household dust, and animal bedding may induce respiratory symptoms in rodents and humans. We assayed the endotoxin, coliform, and dust levels in 20 types of rodent bedding. Endotoxin concentrations were measured by using a commercial test kit, coliform counts were determined by using conventional microbiologic procedures, and dust content was evaluated by using a rotating–tapping shaker. Paper bedding types contained significantly less endotoxin than did other beddin...

  5. Concentration and Size Distribution of Particulate Matter in a Broiler House Ambient Air

    Directory of Open Access Journals (Sweden)

    Ismael Rodrigues Amador

    2016-07-01

    Full Text Available Atmospheric particulate matter (PM is an important constituent of ambient air. The determination of its concentration and size distribution in different environments is essential because of its ability to penetrate deeply into animal and human respiratory tract. In this study, air sampling was performed in a broiler house to estimate the concentration and size distribution of PM emitted along with its activities. Low-vol impactor (< 10 mm, cyclones (< 2.5 e < 1.0 mm, and Sioutas cascade impactor (> 2.5; 1.0 – 2.5; 0.50 – 1.0; 0.25 – 0.50; < 0.25 mm connected with membrane pumps were used. PM10 showed high concentration (209 - 533 mg m-3. PM2.5 and PM1.0 initially showed relatively low concentration (20.8 and 16.0 mg m-3 respectively with significantly increasing levels (412.9 and 344.8 mg m-3 respectively during the samplings. It was also possible to observe the contribution of fine particles. This was evidenced by the high correlation between PM2.5 and PM1.0 and by the profile of particle distribution in the Sioutas sampler. PM concentration levels are considered excessively high, with great potential to affect animal and human health. DOI: http://dx.doi.org/10.17807/orbital.v8i3.847 

  6. Predictors of Airborne Endotoxin Concentrations in Inner City Homes

    Science.gov (United States)

    Mazique, D; Diette, GB; Breysse, PN; Matsui, EC; McCormack, MC; Curtin-Brosnan, J; Williams, D; Peng, RD; Hansel, NN

    2011-01-01

    Few studies have assessed in-home factors which contribute to airborne endotoxin concentrations. In 85 inner-city Baltimore homes, we found no significant correlation between settled dust and airborne endotoxin concentrations. Certain household activities and characteristics, including frequency of dusting, air conditioner use and type of flooring, explained 36–42% of the variability of airborne concentrations. Measurements of both airborne and settled dust endotoxin concentrations may be needed to fully characterize domestic exposure in epidemiologic investigations. PMID:21429483

  7. Growth of lowland broccoli coconut coir dust and peat based growing media using fertigation system

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Asiah; Abdul Rahman, Shyful Azizi; Nordin, Latiffah; Abdullah, Hazlina; Ruslan, Abdul Razak [Malaysian Inst. for Nuclear Technology Research MINT, Bangi (Malaysia). Agrotechnology and Bioscineces Div.; Taib, Mohd Idris [Malaysian Inst. for Nuclear Technology Research MINT, Bangi (Malaysia). Intelligent Group

    2004-07-01

    A study was carried out inside the greenhouse to determine the response of lowland broccoli (Brassica oleracea) plants grown in five mixtures of coconut coir dust and peat as the growing media. The growing mixes were prepared in the following ratios (% by vol): 100% coconut coir dust, 75% coconut coir dust + 25% peat, 50% coconut coir dust + 50% peat, 25% coconut coir dust + 75% peat and 100% peat. The plants were supplied with 200 mg 1-1 nitrogen using a computerized fertigation system developed at MINT Plants grown on 100% peat exhibited reduced plant growth and yield compared to plants grown on mixes containing coconut coir dust. Plants growth and yield were increased on growing media contained > 50% coconut coir dust; however, the highest total plant dry weight, plant height and yield were obtained from plants grown on 100% coconut coir dust. Total nitrogen concentration in the leaves and stems was not significantly different in all mixture of the growing media regardless of whether coconut coir dust or peat was used. In general, nitrate -nitrogen concentrations were lowest in the floret than in the leaves and stem tissues of plants grown on all growing media used in the study. However, nitrate-nitrogen concentrations in the leaves, stems and florets were lowest in the plants grown on 100% peat compared to the plants grown on growing media containing coconut coir dust. The concentrations of nitrate-nitrogen in the florets, which ranged from 290 to 450 mg N kg-l/dry weight, are considered to be under permissible levels by European standards. (Author)

  8. Growth of lowland broccoli coconut coir dust and peat based growing media using fertigation system

    International Nuclear Information System (INIS)

    Asiah Ahmad; Shyful Azizi Abdul Rahman; Latiffah Nordin; Hazlina Abdullah; Abdul Razak Ruslan; Mohd Idris Taib

    2004-01-01

    A study was carried out inside the greenhouse to determine the response of lowland broccoli (Brassica oleracea) plants grown in five mixtures of coconut coir dust and peat as the growing media. The growing mixes were prepared in the following ratios (% by vol): 100% coconut coir dust, 75% coconut coir dust + 25% peat, 50% coconut coir dust + 50% peat, 25% coconut coir dust + 75% peat and 100% peat. The plants were supplied with 200 mg 1-1 nitrogen using a computerized fertigation system developed at MINT Plants grown on 100% peat exhibited reduced plant growth and yield compared to plants grown on mixes containing coconut coir dust. Plants growth and yield were increased on growing media contained > 50% coconut coir dust; however, the highest total plant dry weight, plant height and yield were obtained from plants grown on 100% coconut coir dust. Total nitrogen concentration in the leaves and stems was not significantly different in all mixture of the growing media regardless of whether coconut coir dust or peat was used. In general, nitrate -nitrogen concentrations were lowest in the floret than in the leaves and stem tissues of plants grown on all growing media used in the study. However, nitrate-nitrogen concentrations in the leaves, stems and florets were lowest in the plants grown on 100% peat compared to the plants grown on growing media containing coconut coir dust. The concentrations of nitrate-nitrogen in the florets, which ranged from 290 to 450 mg N kg-l/dry weight, are considered to be under permissible levels by European standards. (Author)

  9. NRC's limit on intake of uranium-ore dust

    International Nuclear Information System (INIS)

    McGuire, S.A.

    1983-04-01

    In 1960 the Atomic Energy Commission adopted an interim limit on the intake by inhalation of airborne uranium-ore dust. This report culminates two decades of research aimed at establishing the adequacy of that limit. The report concludes that the AEC underestimated the time that thorium-230, a constituent of uranium-ore dust, would remain in the human lung. The AEC assumed that thorium-230 in ore dust would behave like uranium with a 120-day biological half-life in the lung. This report concludes that the biological half-life is actually on the order of 1 year. Correcting the AEC's underestimate would cause a reduction in the permitted airborne concentration of uranium-ore dust. However, another factor that cancels the need for that reduction was found. The uranium ore dust in uranium mills was found to occur with very large particle sizes (10-micron activity median aerodynamic diameter). The particles are so large that relatively few of them are deposited in the pulmonary region of the lung, where they would be subject to long-term retention. Instead they are trapped in the upper regions of the respiratory tract, subsequently swallowed, and then rapidly excreted from the body through the gastrointestinal tract. The two effects are of about the same magnitude but in opposing directions. Thus the present uranium-ore dust intake limit in NRC regulations should provide a level of protection consistent with that provided for other airborne radioactive materials. The report recalculates the limit on intake of uranium-ore dust using the derived air concentrations (DAC) from the International Commission on Radiological Protection's recent Publication 30. The report concludes that the silica contained in uranium-ore dust is a greater hazard to workers than the radiological hazard

  10. Accumulation and distribution characteristics of platinum group elements in roadside dusts in Beijing, China.

    Science.gov (United States)

    Gao, Bo; Yu, Yanke; Zhou, Huaidong; Lu, Jin

    2012-06-01

    The concentrations, distribution, and accumulation of platinum group elements (PGEs) were investigated in roadside dusts collected in four different foundational areas in Beijing during February to May 2010. The results showed that PGE levels in all samples were above the average upper crust values, with mean concentrations of 57.5 ng · g(-1) Pd, 28.2 ng · g(-1) Pt, and 9.8 ng · g(-1) Rh, respectively. Palladium concentration has increased rapidly in recent years. The rank of PGE levels in four different functional regions for roadside dusts was: heavy density traffic area > residential area > educational area > tourism area. Palladium, Pt, and Rh concentrations in dusts showed strong positive correlations, indicating a common traffic-related source of these metals. Meanwhile, PGEs in these samples were not correlated with other traffic-related metals except for Cr. The average PGE ratios of road dusts from Beijing were consistent with those in Germany and Western Australia, but lower than those in the United States and Mexico, indicating that various catalyst productions were used in different countries. In addition, grain-size partitioning of PGEs in dusts indicated that concentrations of PGEs differed from one particle size to another. The coarse fraction had higher PGE concentrations than the fine fraction in roadside dusts. These results showed that autocatalyst PGE contamination estimates in the environment would be significantly underestimated if only a fine-grain size fraction (<0.063 mm) is analyzed. Copyright © 2012 SETAC.

  11. Real-time measurement of dust in the workplace using video exposure monitoring: Farming to pharmaceuticals

    International Nuclear Information System (INIS)

    Walsh, P T; Forth, A R; Clark, R D R; Dowker, K P; Thorpe, A

    2009-01-01

    Real-time, photometric, portable dust monitors have been employed for video exposure monitoring (VEM) to measure and highlight dust levels generated by work activities, illustrate dust control techniques, and demonstrate good practice. Two workplaces, presenting different challenges for measurement, were used to illustrate the capabilities of VEM: (a) poultry farming activities and (b) powder transfer operations in a pharmaceutical company. For the poultry farm work, the real-time monitors were calibrated with respect to the respirable and inhalable dust concentrations using cyclone and IOM reference samplers respectively. Different rankings of exposure for typical activities were found on the small farm studied here compared to previous exposure measurements at larger poultry farms: these were mainly attributed to the different scales of operation. Large variations in the ratios of respirable, inhalable and real-time monitor TWA concentrations of poultry farm dust for various activities were found. This has implications for the calibration of light-scattering dust monitors with respect to inhalable dust concentration. In the pharmaceutical application, the effectiveness of a curtain barrier for dust control when dispensing powder in a downflow booth was rapidly demonstrated.

  12. Ice Nucleating Particle Properties in the Saharan Air Layer Close to the Dust Source

    Science.gov (United States)

    Boose, Y.; Garcia, I. M.; Rodríguez, S.; Linke, C.; Schnaiter, M.; Nickovic, S.; Lohmann, U.; Kanji, Z. A.; Sierau, B.

    2015-12-01

    In August 2013 and 2014 measurements of ice nucleating particle (INP) concentrations, aerosol particle size distributions, chemistry and fluorescence were conducted at the Izaña Atmospheric Observatory located at 2373 m asl on Tenerife, west off the African shore. During summer, the observatory is frequently within the Saharan Air Layer and thus often exposed to dust. Absolute INP concentrations and activated fractions at T=-40 to -15°C and RHi=100-150 % were measured. In this study, we discuss the in-situ measured INP properties with respect to changes in the chemical composition, the biological content, the source regions as well as transport pathways and thus aging processes of the dust aerosol. For the first time, ice crystal residues were also analyzed with regard to biological content by means of their autofluorescence signal close to a major dust source region. Airborne dust samples were collected with a cyclone for additional offline analysis in the laboratory under similar conditions as in the field. Both, in-situ and offline dust samples were chemically characterized using single-particle mass spectrometry. The DREAM8 dust model extended with dust mineral fractions was run to simulate meteorological and dust aerosol conditions for ice nucleation. Results show that the background aerosol at Izaña was dominated by carbonaceous particles, which were hardly ice-active under the investigated conditions. When Saharan dust was present, INP concentrations increased by up to two orders of magnitude even at water subsaturated conditions at T≤-25°C. Differences in the ice-activated fraction were found between different dust periods which seem to be linked to variations in the aerosol chemical composition (dust mixed with changing fractions of sea salt and differences in the dust aerosol itself). Furthermore, two biomass burning events in 2014 were identified which led to very low INP concentrations under the investigated temperature and relative humidity

  13. Environmentally dependent dust chemistry of a super Asian dust storm in March 2010: observation and simulation

    Directory of Open Access Journals (Sweden)

    Q. Wang

    2018-03-01

    Full Text Available Near-surface and vertical in situ measurements of atmospheric particles were conducted in Shanghai during 19–23 March 2010 to explore the transport and chemical evolution of dust particles in a super dust storm. An air quality model with optimized physical dust emission scheme and newly implemented dust chemistry was utilized to study the impact of dust chemistry on regional air quality. Two discontinuous dust periods were observed with one traveling over northern China (DS1 and the other passing over the coastal regions of eastern China (DS2. Stronger mixing extents between dust and anthropogenic emissions were found in DS2, reflected by the higher SO2 ∕ PM10 and NO2 ∕ PM10 ratios as well as typical pollution elemental species such as As, Cd, Pb, and Zn. As a result, the concentrations of SO42− and NO3− and the ratio of Ca2+ ∕ Ca were more elevated in DS2 than in DS1 but opposite for the [NH4+] ∕ [SO42−+NO3−] ratio, suggesting the heterogeneous reactions between calcites and acid gases were significantly promoted in DS2 due to the higher level of relative humidity and gaseous pollution precursors. Lidar observation showed a columnar effect on the vertical structure of particle optical properties in DS1 that dust dominantly accounted for ∼ 80–90 % of the total particle extinction from near the ground to ∼ 700 m. In contrast, the dust plumes in DS2 were restrained within lower altitudes while the extinction from spherical particles exhibited a maximum at a high altitude of ∼ 800 m. The model simulation reproduced relatively consistent results with observations that strong impacts of dust heterogeneous reactions on secondary aerosol formation occurred in areas where the anthropogenic emissions were intensive. Compared to the sulfate simulation, the nitrate formation on dust is suggested to be improved in the future modeling efforts.

  14. Environmentally dependent dust chemistry of a super Asian dust storm in March 2010: observation and simulation

    Science.gov (United States)

    Wang, Qiongzhen; Dong, Xinyi; Fu, Joshua S.; Xu, Jian; Deng, Congrui; Jiang, Yilun; Fu, Qingyan; Lin, Yanfen; Huang, Kan; Zhuang, Guoshun

    2018-03-01

    Near-surface and vertical in situ measurements of atmospheric particles were conducted in Shanghai during 19-23 March 2010 to explore the transport and chemical evolution of dust particles in a super dust storm. An air quality model with optimized physical dust emission scheme and newly implemented dust chemistry was utilized to study the impact of dust chemistry on regional air quality. Two discontinuous dust periods were observed with one traveling over northern China (DS1) and the other passing over the coastal regions of eastern China (DS2). Stronger mixing extents between dust and anthropogenic emissions were found in DS2, reflected by the higher SO2 / PM10 and NO2 / PM10 ratios as well as typical pollution elemental species such as As, Cd, Pb, and Zn. As a result, the concentrations of SO42- and NO3- and the ratio of Ca2+ / Ca were more elevated in DS2 than in DS1 but opposite for the [NH4+] / [SO42-+NO3-] ratio, suggesting the heterogeneous reactions between calcites and acid gases were significantly promoted in DS2 due to the higher level of relative humidity and gaseous pollution precursors. Lidar observation showed a columnar effect on the vertical structure of particle optical properties in DS1 that dust dominantly accounted for ˜ 80-90 % of the total particle extinction from near the ground to ˜ 700 m. In contrast, the dust plumes in DS2 were restrained within lower altitudes while the extinction from spherical particles exhibited a maximum at a high altitude of ˜ 800 m. The model simulation reproduced relatively consistent results with observations that strong impacts of dust heterogeneous reactions on secondary aerosol formation occurred in areas where the anthropogenic emissions were intensive. Compared to the sulfate simulation, the nitrate formation on dust is suggested to be improved in the future modeling efforts.

  15. Mortality associated with particulate concentration and Asian dust storms in Metropolitan Taipei

    Science.gov (United States)

    Wang, Yu-Chun; Lin, Yu-Kai

    2015-09-01

    This study evaluates mortality risks from all causes, circulatory diseases, and respiratory diseases associated with particulate matter (PM10 and PM2.5) concentrations and Asian dust storms (ADS) from 2000 to 2008 in Metropolitan Taipei. This study uses a distributed lag non-linear model with Poisson distribution to estimate the cumulative 5-day (lags 0-4) relative risks (RRs) and confidence intervals (CIs) of cause-specific mortality associated with daily PM10 and PM2.5 concentrations, as well as ADS, for total (all ages) and elderly (≥65 years) populations based on study periods (ADS frequently inflicted period: 2000-2004; and less inflicted period: 2005-2008). Risks associated with ADS characteristics, including inflicted season (winter and spring), strength (the ratio of stations with Pollutant Standard Index >100 is increase in PM10 from 10 μg/m3 to 50 μg/m3 was associated with increased all-cause mortality risk with cumulative 5-day RR of 1.10 (95% CI: 1.04, 1.17) for the total population and 1.10 (95% CI: 1.02, 1.18) for elders. Mortality from circulatory diseases for the elderly was related to increased PM2.5 from 5 μg/m3 to 30 μg/m3, with cumulative 5-day RR of 1.21 (95% CI: 1.02, 1.44) from 2005 to 2008. Compared with normal days, the mortality from all causes and circulatory diseases for the elderly population was associated with winter ADS with RRs of 1.05 (95% CI: 1.01, 1.08) and 1.08 (95% CI: 1.01, 1.15), respectively. Moreover, all-cause mortality was associated with shorter and less area-affected ADS with an RR of 1.04 for total and elderly populations from 2000 to 2004. Population health risk differed not only with PM concentration but also with ADS characteristics.

  16. Short-term variability of mineral dust, metals and carbon emission from road dust resuspension

    NARCIS (Netherlands)

    Amato, F.; Schaap, M.; Denier van der Gon, H.A.C.; Pandolfi, M.; Alastuey, A.; Keuken, M.; Querol, X.

    2013-01-01

    Particulate matter (PM) pollution in cities has severe impact on morbidity and mortality of their population. In these cities, road dust resuspension contributes largely to PM and airborne heavy metals concentrations. However, the short-term variation of emission through resuspension is not well

  17. Guanine as a hygienic index for allergological relevant mite infestation in mattress dust

    NARCIS (Netherlands)

    Bronswijk, van J.E.M.H.

    1986-01-01

    Since guanine is not only an essential constituent of vital nucleic acids, but also the main end product of nitrogenous waste excretion in arachnids, it is a potential candidate for a hygienic index for mite activity in house dust. The public health significance of these mites is based on their

  18. Experience with dust suppression in mining a thick, dirty seam

    Energy Technology Data Exchange (ETDEWEB)

    Siepmann, D; Kohlhauer, H

    1975-11-20

    Dust suppression measures used when mining a thick, dirty seam are described. Dust sprays inside and outside the shearer drum helped to reduce coarse dust, but the resulting increase in moisture content of the coal limits the extent to which this method can be used. The shields were also fitted with sprays. Because of the dirt in the seam, continuous, remotely controlled deep infusion was used. This reduced the dust concentration from more than 10 mg/m/sup 3/ to between 3.9 and 6.6 mg/m/sup 3/.

  19. Simulating the meteorology and PM10 concentrations in Arizona dust storms using the Weather Research and Forecasting model with Chemistry (Wrf-Chem).

    Science.gov (United States)

    Hyde, Peter; Mahalov, Alex; Li, Jialun

    2018-03-01

    Nine dust storms in south-central Arizona were simulated with the Weather Research and Forecasting with Chemistry model (WRF-Chem) at 2 km resolution. The windblown dust emission algorithm was the Air Force Weather Agency model. In comparison with ground-based PM 10 observations, the model unevenly reproduces the dust-storm events. The model adequately estimates the location and timing of the events, but it is unable to precisely replicate the magnitude and timing of the elevated hourly concentrations of particles 10 µm and smaller ([PM 10 ]).Furthermore, the model underestimated [PM 10 ] in highly agricultural Pinal County because it underestimated surface wind speeds and because the model's erodible fractions of the land surface data were too coarse to effectively resolve the active and abandoned agricultural lands. In contrast, the model overestimated [PM 10 ] in western Arizona along the Colorado River because it generated daytime sea breezes (from the nearby Gulf of California) for which the surface-layer speeds were too strong. In Phoenix, AZ, the model's performance depended on the event, with both under- and overestimations partly due to incorrect representation of urban features. Sensitivity tests indicate that [PM 10 ] highly relies on meteorological forcing. Increasing the fraction of erodible surfaces in the Pinal County agricultural areas improved the simulation of [PM 10 ] in that region. Both 24-hr and 1-hr measured [PM 10 ] were, for the most part, and especially in Pinal County, extremely elevated, with the former exceeding the health standard by as much as 10-fold and the latter exceeding health-based guidelines by as much as 70-fold. Monsoonal thunderstorms not only produce elevated [PM 10 ], but also cause urban flash floods and disrupt water resource deliveries. Given the severity and frequency of these dust storms, and conceding that the modeling system applied in this work did not produce the desired agreement between simulations and

  20. Geochemical characterization of critical dust source regions in the American West

    Science.gov (United States)

    Aarons, Sarah M.; Blakowski, Molly A.; Aciego, Sarah M.; Stevenson, Emily I.; Sims, Kenneth W. W.; Scott, Sean R.; Aarons, Charles

    2017-10-01

    The generation, transport, and deposition of mineral dust are detectable in paleoclimate records from land, ocean, and ice, providing valuable insight into earth surface conditions and cycles on a range of timescales. Dust deposited in marine and terrestrial ecosystems can provide critical nutrients to nutrient-limited ecosystems, and variations in dust provenance can indicate changes in dust production, sources and transport pathways as a function of climate variability and land use change. Thus, temporal changes in locations of dust source areas and transport pathways have implications for understanding interactions between mineral dust, global climate, and biogeochemical cycles. This work characterizes dust from areas in the American West known for dust events and/or affected by increasing human settlement and livestock grazing during the last 150 years. Dust generation and uplift from these dust source areas depends on climate and land use practices, and the relative contribution of dust has likely changed since the expansion of industrialization and agriculture into the western United States. We present elemental and isotopic analysis of 28 potential dust source area samples analyzed using Thermal Ionization Mass Spectrometry (TIMS) for 87Sr/86Sr and 143Nd/144Nd composition and Multi-Collector Inductively Coupled Plasma Mass Spectrometer (MC-ICPMS) for 176Hf/177Hf composition, and ICPMS for major and trace element concentrations. We find significant variability in the Sr, Nd, and Hf isotope compositions of potential source areas of dust throughout western North America, ranging from 87Sr/86Sr = 0.703699 to 0.740236, εNd = -26.6 to 2.4, and εHf = -21.7 to -0.1. We also report differences in the trace metal and phosphorus concentrations in the geologic provinces sampled. This research provides an important resource for the geochemical tracing of dust sources and sinks in western North America, and will aid in modeling the biogeochemical impacts of increased

  1. The Spatio-Temporal Distribution of Particulate Matter during Natural Dust Episodes at an Urban Scale.

    Directory of Open Access Journals (Sweden)

    Helena Krasnov

    Full Text Available Dust storms are a common phenomenon in arid and semi-arid areas, and their impacts on both physical and human environments are of great interest. Number of studies have associated atmospheric PM pollution in urban environments with origin in natural soil/dust, but less evaluated the dust spatial patterns over a city. We aimed to analyze the spatial-temporal behavior of PM concentrations over the city of Beer Sheva, in southern Israel, where dust storms are quite frequent. PM data were recorded during the peak of each dust episode simultaneously in 23 predetermined fixed points around the city. Data were analyzed for both dust days and non-dust days (background. The database was constructed using Geographic Information System and includes distributions of PM that were derived using inverse distance weighted (IDW interpolation. The results show that the daily averages of atmospheric PM10 concentrations during the background period are within a narrow range of 31 to 48 μg m-3 with low variations. During dust days however, the temporal variations are significant and can range from an hourly PM10 concentration of 100 μg m-3 to more than 1280 μg m-3 during strong storms. IDW analysis demonstrates that during the peak time of the storm the spatial variations in PM between locations in the city can reach 400 μg m-3. An analysis of site and storm contribution to total PM concentration revealed that higher concentrations are found in parts of the city that are proximal to dust sources. The results improve the understanding of the dynamics of natural PM and the dependence on wind direction. This may have implications for environmental and health outcomes.

  2. Assessment of elemental contamination in road dust using EDXRF

    International Nuclear Information System (INIS)

    Saradhi, I.V.; Sandeep, P.; Pandit, G.G.

    2014-01-01

    Road dust samples were collected in different locations of heavy traffic, medium traffic, express way and industrial areas of Mumbai. The concentrations of various elements (Mg, Al, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn and Pb) in road dust samples were analyzed using EDXRF. The average elemental profile of road dust in Mumbai was comparable with studies carried out in other countries with slight variations. The estimated geo accumulation indices and enrichment factors indicated moderate elemental contamination and enrichment of anthropogenic elements in road dust samples. Factor analysis of elemental data resolved four sources namely crustal, tyre wear, vehicular/industrial emissions and break wear. (author)

  3. Continuous dust monitoring in headings in underground coal mines

    Directory of Open Access Journals (Sweden)

    Kazimierz Lebecki

    2016-01-01

    Full Text Available The article presents hazardous conditions of airborne dust based on the results of measurements of dust concentration taken at work-places at a underground rock-coal face drilled by a heading machine with combined ventilation (suction and forced ventilation with dust collector. The measurements were taken using three methods in order to examine and assess the actual conditions within the excavation subject to the study. The measurement results and conclusions show major difficulties in achieving MAC levels. Research conclusions indicate the low efficiency of collective and personal measures applied to protect against dust harmful to health as well as the need to improve them.

  4. Particulate emission abatement for Krakow boiler houses

    Energy Technology Data Exchange (ETDEWEB)

    Wysk, R.

    1995-12-31

    Among the many strategies for improving air quality in Krakow, one possible method is to adapt new and improved emission control technology. This project focuses on such a strategy. In order to reduce dust emissions from coal-fueled boilers, a new device called a Core Separator has been introduced in several boiler house applications. This advanced technology has been successfully demonstrated in Poland and several commercial units are now in operation. Particulate emissions from the Core Separator are typically 3 to 5 times lower than those from the best cyclone collectors. It can easily meet the new standard for dust emissions which will be in effect in Poland after 1997. The Core Separator is a completely inertial collector and is based on a unique recirculation method. It can effectively remove dust particles below 10 microns in diameter, the so-called PM-10 emissions. Its performance approaches that of fabric filters, but without the attendant cost and maintenance. It is well-suited to the industrial size boilers located in Krakow. Core Separators are now being marketed and sold by EcoInstal, one of the leading environmental firms in Poland, through a cooperative agreement with LSR Technologies.

  5. Trichothecene mycotoxins and their determinants in settled dust related to grain production.

    Science.gov (United States)

    Nordby, Karl-Christian; Halstensen, Anne Straumfors; Elen, Oleif; Clasen, Per-Erik; Langseth, Wenche; Kristensen, Petter; Eduard, Wijnand

    2004-01-01

    We hypothesise that inhalant exposure to mycotoxins causes developmental outcomes and certain hormone-related cancers that are associated with grain farming in an epidemiological study. The aim of the present study was to identify and validate determinants of measured trichothecene mycotoxins in grain dust as work environmental trichothecene exposure indicators. Settled grain dust was collected in 92 Norwegian farms during seasons of 1999 and 2000. Production characteristics and climatic data were studied as determinants of trichothecenes in settled dust samples obtained during the production of barley (N = 59), oats (N = 32), and spring wheat (N = 13). Median concentrations of trichothecenes in grain dust were grain dust in this study. Differences in cereal species, production properties and districts contributed less to explain mycotoxin concentrations. Fungal forecasts are validated as indicators of mycotoxin exposure of grain farmers and their use in epidemiological studies may be warranted.

  6. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  7. Can Asian Dust Trigger Phytoplankton Blooms in the Oligotrophic Northern South China Sea?

    Science.gov (United States)

    Wang, Sheng Hsiang; Hsu, Nai-Yung Christina; Tsay, Si-Chee; Lin, Neng-Huei; Sayer, Andrew M.; Huang, Shih-Jen; Lau, William K. M.

    2012-01-01

    Satellite data estimate a high dust deposition flux (approximately 18 g m(exp-2 a(exp-1) into the northern South China Sea (SCS). However, observational evidence concerning any biological response to dust fertilization is sparse. In this study, we combined long-term aerosol and chlorophyll-a (Chl-a) measurements from satellite sensors (MODIS and SeaWiFS) with a 16-year record of dust events from surface PM10 observations to investigate dust transport, flux, and the changes in Chl-a concentration over the northern SCS. Our result revealed that readily identifiable strong dust events over this region, although relatively rare (6 cases since 1994) and accounting for only a small proportion of the total dust deposition (approximately 0.28 g m(exp-2 a(exp-1), do occur and could significantly enhance phytoplankton blooms. Following such events, the Chl-a concentration increased up to 4-fold, and generally doubled the springtime background value (0.15 mg m(exp-3). We suggest these heavy dust events contain readily bioavailable iron and enhance the phytoplankton growth in the oligotrophic northern SCS.

  8. Tropomyosin or not tropomyosin, what is the relevant allergen in house dust mite and snail cross allergies?

    Science.gov (United States)

    Bessot, J C; Metz-Favre, C; Rame, J M; De Blay, F; Pauli, G

    2010-02-01

    Since tropomyosin is cross reactive in many arthropods, it was assumed that this highly conserved protein could be responsible for cross reactions in house dust mite (HDM) allergic patients who experienced adverse reactions after crustacean and mollusc ingestion. Here we report two clinical cases where the role of tropomyosin is a matter of debate. In the first case, the clinical history, as well as the results of in vivo and in vitro investigations, are in favour of a shrimp allergy without any snail allergy in a patient sensitized to HDM. In the second, the clinical history and the cutaneous tests are in favour of an allergy to snails without any allergy to shrimps in a patient suffering from HDM allergies. The clinical presentation is different in shrimp and snail allergies. In shrimp allergy, symptoms are mainly urticaria or angio-oedema. In snail allergies, adverse reactions are especially severe asthma. Shrimp tropomyosin is a dominant allergen in crustaceans whereas has a much less prominent role in HDM sensitization. Cross reactivities between HDM and snails have been confirmed by inhibition experiments. However, tropomyosin appears to be a minor allergen or even is not involved in snail allergy. It is necessary to clarify the allergens shared between HDMI and snails. The effects of HDM immunotherapy in snail allergy are questioned. Knowledge of taxonomy can contribute to more precise evaluation of cross reactivities between crustaceans and molluscs.

  9. Microbial degradation of coconut coir dust for biomass production

    Energy Technology Data Exchange (ETDEWEB)

    Uyenco, F.R.; Ochoa, J.A.K.

    Several species of white-rot fungi were studied for its ability to degrade the lignocellulose components of coir dust at optimum conditions. The most effective fungi was Phanerochaeta chrysosporium UPCC 4003. This organism degraded the lignocellulose complex of coir dust at a rate of about 25 percent in 4 weeks. The degradation process was carried on with minimal nitrogen concentration, coconut water supplementation and moisture levels between 85-90 percent. Shake flask cultures of the degraded coir dust using cellulolytic fungi were not effective. In fermentor cultures with Chaetomium cellulolyticum UPCC 3934, supplemented coir dust was converted into a microbial biomass product (MBP) with 15.58 percent lignin, 19.20 percent cellulose and 18.87 percent protein. More work is being done on the utilization of coir dust on a low technology.

  10. Intrapulmonary reactions of workers exposed to dust and ozone

    Energy Technology Data Exchange (ETDEWEB)

    Tsunoda, T; Nakadate, T; Sakurai, M; Sakurai, Y

    1984-01-01

    Forty-one dust-and-ozone-exposed and 37 nonexposed workers, belonging to the Research and Development Division of a photo-copier manufacturing industry, were examined to assess the effect of the exposure to carbon, iron and resin dust and ozone in the air of the work environment by means of questionnaires on their physical condition, smoking habits and exposure history by interview, chest X-rays, testing of ventilatory functions, transcutaneous PO2 (tcPO2) test and H2O2-induced hemolysis test. The following results were obtained. Respirable dust concentrations in the air of the work place were 0.1-1.0 mg/m3, total dust concentrations 0.2-2.0 mg/m3, and ozone concentrations 0.004-0.06 ppm (0.008-0.12 mg/m3). According to the Japanese Classification of Radiographs of Pneumoconioses, the exposed workers showed a higher rate of profusion 0/1 and over, and category 1 and over (1/0 and over) than the nonexposed workers. Ventilatory function testing revealed no difference between exposed workers and nonexposed workers, but small airway narrowing was suspected in smoking workers in comparison with nonsmoking workers. Transcutaneous PO2 showed no difference between exposed and nonexposed workers, between smoking and nonsmoking workers, and between any of the paired six combinations out of the four groups of workers, i.e., nonsmoking and nonexposed, nonsmoking and exposed, smoking and nonexposed, and smoking and exposed. It was estimated by H2O2-induced hemolysis test that smoking and/or dust exposure, especially long-term exposure, gave rise to aggravation of fragility of the erythrocyte membrane by lipid peroxidation with ozone or active oxygen produced by the reaction of dust and alveolar macrophages.

  11. [Effect of 1-year specific immunotherapy with standardized house dust mite vaccine on mild to moderate allergic asthmatic patients].

    Science.gov (United States)

    Wang, Hong-yu; Lin, Xiao-ping; Hao, Chuang-li; Zhang, Chun-qing; Sun, Bao-qing; Zheng, Jin-ping; Chen, Ping; Sheng, Jin-yun; Wu, Adrian; Zhong, Nan-shan

    2006-10-01

    To evaluate the clinical efficacy and safety of specific immunotherapy (SIT) with standardized house dust mite (HDM) vaccine on allergic asthmatic patients. The investigation was a multicentre, randomized, double-blind, placebo-controlled clinical study. 132 patients with mild to moderate asthma who were allergic to HDM, recruited from three hospitals of China (The First Affiliated Hospital of Guangzhou Medical College, Shenyang General Military Hospital, Suzhou Children's Hospital), were randomly allocated to the active group (n = 66) or the control group (n = 66) respectively. The active group received SIT with a standardized depot Dermatophagoides pteronyssinus (Der p) extract absorbed to aluminium hydroxide (Alutard SQ, ALK-Abelló, Denmark), while the control group received a placebo containing histamine dihydrochloride by subcutaneous injections for 1 year. Treatment of each group was started from the initial concentration. Updosing was performed with weekly injections from four 10-fold dose-increase vials (active group: 100, 1,000, 10,000, 100,000 SQ-U/ml, control group: 0.01, 0.1, 1.0, 10 microg/ml. 100,000 SQ-U/ml of Der p extract contains 9.8 microg/ml of the majoy allergen Der p1). The single-dose was injected weekly with 0.2, 0.4, 0.8 ml of each concentration in turn from the preceding 3 vials, totally for 9 weeks. Subsequently, the dose with 0.1, 0.2, 0.4, 0.6, 0.8 ml of the highest concentration was injected weekly from the 10th-14th week and a maintenance dose with 1 ml was reached at the 15th week. The dosing interval was then gradually increased to 2, 4, 6 weeks until the end of the first 26-weeks updosing phase (phase I, H(1)). Thereafter, the dosing continued at 6-week intervals for maintenance phase (phase II, H(2)) till the end of the complete treatment. The patient was observed for at least 30 minutes in the clinic after each injection. A total of 132 subjects were randomized and 129 subjects (64 in the active group, 65 in the control group

  12. Are housing professionals born or made? The role of education and identity amongst housing professionals in Ireland.

    OpenAIRE

    Butler, Deborah

    2010-01-01

    The concept of a housing professional is a new and often disputed term. Qualitative research into the culture and identity of occupational groups involved in social housing provision and management has been relatively scarce. Research has concentrated, almost exclusively, on the individual involved in the housing construction and output side of housing provision. This neglect is surprising given the importance of housing in people‟s lives. The thesis examines the identities, experiences and e...

  13. Application of aerosol speciation data as an in situ dust proxy for validation of the Dust Regional Atmospheric Model (DREAM)

    Science.gov (United States)

    Shaw, Patrick

    The Dust REgional Atmospheric Model (DREAM) predicts concentrations of mineral dust aerosols in time and space, but validation is challenging with current in situ particulate matter (PM) concentration measurements. Measured levels of ambient PM often contain anthropogenic components as well as windblown mineral dust. In this study, two approaches to model validation were performed with data from preexisting air quality monitoring networks: using hourly concentrations of total PM with aerodynamic diameter less than 2.5 μm (PM 2.5); and using a daily averaged speciation-derived soil component. Validation analyses were performed for point locations within the cities of El Paso (TX), Austin (TX), Phoenix (AZ), Salt Lake City (UT) and Bakersfield (CA) for most of 2006. Hourly modeled PM 2.5 did not validate at all with hourly observations among the sites (combined R hourly values). Aerosol chemical speciation data distinguished between mineral (soil) dust from anthropogenic ambient PM. As expected, statistically significant improvements in correlation among all stations (combined R = 0.16, N = 343 daily values) were found when the soil component alone was used to validate DREAM. The validation biases that result from anthropogenic aerosols were also reduced using the soil component. This is seen in the reduction of the root mean square error between hourly in situ versus hourly modeled (RMSE hourly = 18.6 μg m -3) and 24-h in situ speciation values versus daily averaged observed (RMSE soil = 12.0 μg m -3). However, the lack of a total reduction in RMSE indicates there is still room for improvement in the model. While the soil component is the theoretical proxy of choice for a dust transport model, the current sparse and infrequent sampling is not ideal for routine hourly air quality forecast validation.

  14. Long-term variability of dust-storms in Iceland

    Science.gov (United States)

    Dagsson-Waldhauserová, Pavla; Ólafsson, Haraldur; Arnalds, Ólafur

    2013-04-01

    Iceland is a volcanic island in the North Atlantic Ocean with maritime climate. In spite of moist climate, large areas are with limited vegetation cover where >40% of Iceland is classified with considerable to very severe erosion and 21% of Iceland are volcanic sandy deserts. Natural emissions from these sources influenced by strong winds affect not only regional air quality in Iceland ("Reykjavik haze") but dust particles are transported over the Atlantic ocean and Arctic Ocean > 1000 km at times. The study places Icelandic dust production area into international perspective, present long term frequency of dust storm events in NE Iceland, and estimate dust aerosol concentrations during reported dust events. Meteorological observations with dust presence codes and related visibility were used to identify the frequency and the long-term changes in dust production in NE Iceland. There were annually 16.4 days on average with reported dust observations on weather stations within the NE erosion area, indicating extreme dust plume activity and erosion within the NE deserts, even though the area is covered with snow during the major part of winter. During the 2000s the highest occurrence of dust events in six decades was reported. We have measured saltation and aeolian transport during dust/volcanic ash storms in Iceland which give some of the most intense wind erosion events ever measured. Icelandic dust affects the ecosystems over much of Iceland and causes regional haze. It is likely to affect the ecosystems of the oceans around Iceland, and it brings dust that lowers the albedo of the Icelandic glaciers, increasing melt-off due to global warming. The study indicates that Icelandic dust is not only a substantial source for regional air pollution, but may be considered to contribute to the Arctic haze phenomena and Arctic air pollution.

  15. [Investigation of heavy metal and polycyclic aromatic hydrocarbons contamination in street dusts in urban Beijing].

    Science.gov (United States)

    Xiang, Li; Li, Ying-Xia; Shi, Jiang-Hong; Liu, Jing-Ling

    2010-01-01

    This paper investigated the contamination levels of heavy metal and polycyclic aromatic hydrocarbons (PAHs) in street dusts in different functional areas in urban Beijing. Results show that the mean concentrations of Cd, Hg, Cr, Cu, Ni, Pb and Zn in street dusts in Beijing are 710 ng/g, 307 ng/g, 85.0 microg/g, 78.3 microg/g, 41.1 microg/g, 69.6 microg/g and 248.5 microg/g, respectively, which are significantly lower than those in most cities around the world and Shenyang, Shanghai in China. The mean concentration of Sigma 16PAHs in street dusts in Beijing is 0.398 microg/g, which is also lower than those of Handan, Tianjin and Shanghai. Non-parametric Friedman test demonstrates significant differences of heavy metal contents on street dusts from different functional zones. Street dusts in residential area and parks have lower heavy metal and PAHs concentrations than the street dusts from areas of high traffic density. The concentrations of heavy metals follow the order Zn > Cr > Cu > Pb > Ni > Cd > Hg, which is consistent with the situation in other cities around the world. The geoaccumulation index analysis shows that street dust in urban Beijing is moderately polluted by Cd, Zn and Cu, little polluted by Cr and Pb and practically unpolluted by Ni. The contamination levels of Sigma 16PAHs on street dusts vary greatly in different functional zones with parks little polluted, residential areas moderately to strongly polluted and traffic related areas strongly polluted to extremely polluted. Mass loading of heavy metals and PAHs is largely associated with street dusts of size range < 300 microm. Therefore, the urban sweeping vehicles should update the dust sweeping devices to remove not only the fine particle but also the coarser particles.

  16. Inert dusts and their effects on the poultry red mite (Dermanyssus gallinae)

    DEFF Research Database (Denmark)

    Kilpinen, Ole; Steenberg, Tove

    2009-01-01

    commonly applied alternative control methods for poultry red mite in Europe. This development has occurred despite a lack of knowledge of the efficacy of the different types of inert dusts and how this is affected by environmental parameters, e.g. the high relative humidity found in poultry houses....... In this laboratory study the efficacy of different commercial inert dust products against D. gallinae is compared. All tested compounds killed mites, but there was a clear ranking of efficacy (measured as weight loss after 24 h and as time until 50% mortality), particularly at 75% relative humidity (RH). At 85% RH...

  17. Effect of Saw Dust Biochar and NPK 15:15:15 Inorganic Fertilizer on ...

    African Journals Online (AJOL)

    A factorialexperiment was conducted in the screen house of Bowen University, Iwo, Nigeria to examine the response of Moringa oleifera Lam. seedlings to saw dust biochar and NPK 15:15:15 inorganic fertilizer amendments. The plants were grown for twelve weeks in top soil (0-30cm) collected from an Oxisol in the ...

  18. Coal dust contiguity-induced changes in the concentration of TNF- and NF- B p65 on the ocular surface

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z.Y.; Hong, J.; Liu, Z.Y.; Jin, X.D.; Gu, C.H. [China Medical University, Shenyang (China)

    2009-07-01

    To observe the influence of coal dust on ocular surface of coal miners and rabbits with coal dust contiguity on expression TNF- and NF- Bp65 and dry eye occurrence. Expression TNF- and NF- Bp65 in ocular surface were determined. Results showed tear production, BUT and lysozyme decreased for coal miners and rabbits with coal dust contiguity. Coal dust exposure was linked to development of xerophthalmia, and induced a higher expression of NF- B p65 and TNF- perhaps as a mechanism to resist coal dust ocular surface injury.

  19. Respiratory allergen from house dust mite is present in human milk and primes for allergic sensitization in a mouse model of asthma.

    Science.gov (United States)

    Macchiaverni, P; Rekima, A; Turfkruyer, M; Mascarell, L; Airouche, S; Moingeon, P; Adel-Patient, K; Condino-Neto, A; Annesi-Maesano, I; Prescott, S L; Tulic, M K; Verhasselt, V

    2014-03-01

    There is an urgent need to identify environmental risk and protective factors in early life for the prevention of allergy. Our study demonstrates the presence of respiratory allergen from house dust mite, Der p 1, in human breast milk. Der p 1 in milk is immunoreactive, present in similar amounts as dietary egg antigen, and can be found in breast milk from diverse regions of the world. In a mouse model of asthma, oral exposure to Der p through breast milk strongly promotes sensitization rather than protect the progeny as we reported with egg antigen. These data highlight that antigen administration to the neonate through the oral route may contribute to child allergic sensitization and have important implications for the design of studies assessing early oral antigen exposure for allergic disease prevention. The up-to-now unknown worldwide presence of respiratory allergen in maternal milk allows new interpretation and design of environmental control epidemiological studies for allergic disease prevention. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. The effect of encasings on quality of life in adult house dust mite allergic patients with rhinitis, asthma and/or atopic dermatitis.

    Science.gov (United States)

    Terreehorst, I; Duivenvoorden, H J; Tempels-Pavlica, Z; Oosting, A J; de Monchy, J G R; Bruijnzeel-Koomen, C A F M; van Wijk, R Gerth

    2005-07-01

    Environmental control has been put forward as an integral part of the management of house dust mite (HDM) allergy in sensitized patients. To validate this statement allergic disorders involved in HDM allergy--allergic asthma, rhinitis and atopic eczema/dermatitis syndrome (AEDS)--should be taken together and studied in terms of the efficacy of environmental control. Because a generic quality of life questionnaire exceeds the border of disease, this may be used as major outcome parameter. To study the effects of bedding encasings in HDM allergic patients with asthma, rhinitis and AEDS. A total of 224 adult HDM allergic patients with rhinitis and/or asthma and/or dermatitis were randomly allocated impermeable or nonimpermeable encasings for mattress, pillow and duvet. Short form 36 (SF-36) was filled in at baseline and after 12 months. Lower physical (P = 0.01) and emotional (P effect was seen of encasings on either sumscore. Bedding encasings do not improve quality of life in a mixed population of subjects with combinations with rhinitis, asthma and atopic dermatitis and sensitized to HDMs.

  1. Assessment of respirable dust exposures in an opencast coal mine.

    Science.gov (United States)

    Onder, M; Yigit, E

    2009-05-01

    All major opencast mining activities produce dust. The major operations that produce dust are drilling, blasting, loading, unloading, and transporting. Dust not only deteriorates the environmental air quality in and around the mining site but also creates serious health hazards. Therefore, assessment of dust levels that arise from various opencast mining operations is required to prevent and minimize the health risks. To achieve this objective, an opencast coal mining area was selected to generate site-specific emission data and collect respirable dust measurement samples. The study covered various mining activities in different locations including overburden loading, stock yard, coal loading, drilling, and coal handling plant. The dust levels were examined to assess miners' exposure to respirable dust in each of the opencast mining areas from 1994 to 2005. The data obtained from the dust measurement studies were evaluated by using analysis of variance (ANOVA) and the Tukey-Kramer procedure. The analyses were performed by using Minitab 14 statistical software. It was concluded that, drilling operations produce higher dust concentration levels and thus, drill operators may have higher incidence of respiratory disorders related to exposure to dust in their work environment.

  2. The influence of organic-containing soil dust on ice nucleation and cloud properties

    Science.gov (United States)

    Hummel, Matthias; Grini, Alf; Berntsen, Terje K.; Ekman, Annica

    2017-04-01

    Natural mineral dust from desert regions is known to be the most important contributor to atmospheric ice-nucleating particles (INP) which induce heterogeneous ice nucleation in mixed-phase clouds. Its ability to nucleate ice effectively is shown by various laboratory (Hoose and Möhler 2012) and field results (DeMott et al. 2015) and its abundance in ice crystal residuals has also been shown (Cziczo et al. 2013). Thus it is an important player when representing mixed-phase clouds in climate models. MODIS satellite data indicate that 1 /4 of the global dust emission originates from semi-arid areas rather than from arid deserts (Ginoux et al. 2012). Here, organic components can mix with minerals within the soil and get into the atmosphere. These so-called 'soil dust' particles are ice-nucleating active at high sub-zero temperatures, i.e. at higher temperatures than pure desert dust (Steinke et al. 2016). In this study, soil dust is incorporated into the Norwegian Earth System Model (NorESM, Bentsen et al. 2013) and applied to a modified ice nucleation parameterization (Steinke et al. 2016). Its influence on the cloud ice phase is evaluated by comparing a control run, where only pure desert dust is considered, and a sensitivity experiment, where a fraction of the dust emissions are classified as soil dust. Both simulations are nudged to ERA-interim meteorology and they have the same loading of dust emissions. NorESM gives a lower annual soil dust emission flux compared to Ginoux et al. (2012), but the desert dust flux is similar to the MODIS-retrieved data. Although soil dust concentrations are much lower than desert dust, the NorESM simulations indicate that the annual INP concentrations from soil dust are on average lower by a just a factor of 4 than INP concentrations from pure desert dust. The highest soil dust INP concentrations occur at a lower height than for desert dust, i.e at warmer temperatures inside mixed-phase clouds. Furthermore, soil dust INP

  3. DustEM: Dust extinction and emission modelling

    Science.gov (United States)

    Compiègne, M.; Verstraete, L.; Jones, A.; Bernard, J.-P.; Boulanger, F.; Flagey, N.; Le Bourlot, J.; Paradis, D.; Ysard, N.

    2013-07-01

    DustEM computes the extinction and the emission of interstellar dust grains heated by photons. It is written in Fortran 95 and is jointly developed by IAS and CESR. The dust emission is calculated in the optically thin limit (no radiative transfer) and the default spectral range is 40 to 108 nm. The code is designed so dust properties can easily be changed and mixed and to allow for the inclusion of new grain physics.

  4. Indoor environment in Swedish passive houses

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Langer, Sarka; Bloom, Erica Bloom

    2014-01-01

    The purpose of this study was to evaluate the indoor air quality (IAQ) in newly built low energy houses. Measurements were performed in 22 passive houses and 21 conventional buildings during 2012-2013 and 2013-2014 heating seasons. The measured parameters were temperature, relative humidity......, concentration of CO2, NO2, formaldehyde, volatile organic compounds, and live microbiological flora. Air exchange rates (AER) were determined from the concentration-time profiles of CO2. The median AER was slightly higher in the passive houses than in conventional buildings (0.66 h-1 vs. 0.60 h-1). The median...... concentrations in passive houses and conventional buildings were 9.7 and 11 μg/m3, respectively, for NO2, 12 and 16 μg/m3 for formaldehyde, and 230 and 145 μg/m3 for TVOC. The indoor microbiological flora did not differ, with a few exceptions, from outdoors. The IAQ in the passive buildings was judged...

  5. Impact of Dust Radiative Forcing upon Climate. Chapter 13

    Science.gov (United States)

    Miller, Ronald L.; Knippertz, Peter; Perez Garcia-Pando, Carlos; Perlwitz, Jan P.; Tegan, Ina

    2014-01-01

    Dust aerosols perturb the atmospheric radiative flux at both solar and thermal wavelengths, altering the energy and water cycles. The climate adjusts by redistributing energy and moisture, so that local temperature perturbations, for example, depend upon the forcing over the entire extent of the perturbed circulation. Within regions frequently mixed by deep convection, including the deep tropics, dust particles perturb the surface air temperature primarily through radiative forcing at the top of the atmosphere (TOA). Many models predict that dust reduces global precipitation. This reduction is typically attributed to the decrease of surface evaporation in response to dimming of the surface. A counterexample is presented, where greater shortwave absorption by dust increases evaporation and precipitation despite greater dimming of the surface. This is attributed to the dependence of surface evaporation upon TOA forcing through its influence upon surface temperature and humidity. Perturbations by dust to the surface wind speed and vegetation (through precipitation anomalies) feed back upon the dust aerosol concentration. The current uncertainty of radiative forcing attributed to dust and the resulting range of climate perturbations calculated by models remain a useful test of our understanding of the mechanisms relating dust radiative forcing to the climate response.

  6. Long-term variability of dust events in Iceland (1949-2011)

    Science.gov (United States)

    Dagsson-Waldhauserova, P.; Arnalds, O.; Olafsson, H.

    2014-12-01

    The long-term frequency of atmospheric dust observations was investigated for the southern part of Iceland and interpreted together with earlier results obtained from northeastern (NE) Iceland (Dagsson-Waldhauserova et al., 2013). In total, over 34 dust days per year on average occurred in Iceland based on conventionally used synoptic codes for dust observations. However, frequent volcanic eruptions, with the re-suspension of volcanic materials and dust haze, increased the number of dust events fourfold (135 dust days annually). The position of the Icelandic Low determined whether dust events occurred in the NE (16.4 dust days annually) or in the southern (S) part of Iceland (about 18 dust days annually). The decade with the most frequent dust days in S Iceland was the 1960s, but the 2000s in NE Iceland. A total of 32 severe dust storms (visibility typically warm, occurring during summer/autumn (May-September) and during mild southwesterly winds, while the subarctic dust events (S Iceland) were mainly cold, occurring during winter/spring (March-May) and during strong northeasterly winds. About half of the dust events in S Iceland occurred in winter or at sub-zero temperatures. A good correlation was found between particulate matter (PM10) concentrations and visibility during dust observations at the stations Vík and Stórhöfði. This study shows that Iceland is among the dustiest areas of the world and that dust is emitted year-round.

  7. Studies on airborne dust particles by neutron activation analysis

    International Nuclear Information System (INIS)

    Aoki, Atsushi; Ishii, Taka; Tomiyama, Tsuyoshi; Yamamoto, Isao.

    1974-01-01

    Neutron activation analysis was performed on the airborne dust particles collected at six places with different contaminating circumstances in Kyoto city and the suburbs of Okayama city, using an open type low volume air sampler with a membrance filter attached. Radioactivation by neutrons was performed with the reactor in the Research Reactor Institute of Kyoto University. Short half-life nuclides activated by thermal neutrons were measured. The concentration of airborne dust was usually high in November and December, while Na, Mn, K, etc. probably owing to soil origin showed similar seasonal change to the dust particles, as expected. The concentrations Cl and Br were in proportion to traffic volume, and it was considered to be caused by the exhaust gas from cars. Zn, V. et. were thick in factory areas, which seemed to show the relationship with oil fuel consumption. (Kobatake, H.)

  8. Signaling Pathways Involved in Lunar Dust Induced Cytotoxicity

    Science.gov (United States)

    Zhang, Ye; Lam, Chiu-Wing; Scully, Robert R.; Williams, Kyle; Zalesak, Selina; Wu, Honglu; James, John T.

    2014-01-01

    The Moon's surface is covered by a layer of fine, reactive dust. Lunar dust contain about 1-2% of very fine dust (pathways involved in lunar dust-induced toxicity. F344 rats were exposed for 4 weeks (6h/d; 5d/wk) in nose-only inhalation chambers to concentrations of 0 (control air), 2.1, 6.1, 21, and 61 mg/m(exp 3) of lunar dust. Five rats per group were euthanized 1 day, 1 week, 1 month, and 3 months after the last inhalation exposure. The total RNAs were isolated from the blood or lung tissue after being lavaged, using the Qigen RNeasy kit. The Rat Fibrosis RT2 Profile PCR Array was used to profile the expression of 84 genes relevant to fibrosis. The genes with significant expression changes are identified and the gene expression data were further analyzed using IPA pathway analysis tool to determine the signaling pathways with significant changes.

  9. Carbon dioxide production in animal houses

    DEFF Research Database (Denmark)

    Pedersen, Søren; Blanes-Vidal, Victoria; Joergensen, H.

    2008-01-01

    cellars are emptied regularly in a four weeks interval. Due to a high and variable carbon dioxide production in deep straw litter houses and houses with indoor storage of manure longer than four weeks, we do not recommend to calculate the ventilation flow based on the carbon dioxide concentration......This article deals with carbon dioxide production from farm animals; more specifically, it addresses the possibilities of using the measured carbon dioxide concentration in animal houses as basis for estimation of ventilation flow (as the ventilation flow is a key parameter of aerial emissions from...... animal houses). The investigations include measurements in respiration chambers and in animal houses, mainly for growing pigs and broilers. Over the last decade a fixed carbon dioxide production of 185 litres per hour per heat production unit, hpu (i.e. 1000 W of the total animal heat production at 20o...

  10. Pesticides Present in Migrant Farmworker Housing in North Carolina

    Science.gov (United States)

    Arcury, Thomas A.; Lu, Chensheng; Chen, Haiying; Quandt, Sara A.

    2014-01-01

    Background Migrant farmworkers are exposed to pesticides at work. Housing provided to migrant farmworkers may also expose them to pesticides, increasing their health risks. This analysis (1) describes the presence of organophosphorous (OP) and pyrethroid pesticides in North Carolina migrant farmworker houses, and (2) delineates associations of farmworker camp characteristics with pesticide detection and concentration. Methods In 2010, 186 migrant farmworkers camps in NC were recruited (participation rate of 82.3%); pesticide wipe samples for 176 houses were analyzed. Tobacco is the predominant hand-harvested crop in this region. Two farmworkers per camp completed interviews; a third assisted with a housing inspection. Gas chromatography–mass spectrometry was used to detect OP and pyrethroid pesticides. Covariates of pesticide detection and concentration were determined with ANOVA and Tobit regression. Results OPs were found in 166 of 176 houses (average of 2.4/house); pyrethroids were found in 171 houses (average of 4.3/house). The number of different OPs detected in each camp and concentrations of these OPs were not associated with camp and housing characteristics. The number of different pyrethroids detected in each camp and concentrations of these pyrethroids were associated with camps having residents with H2-A visas, a posted North Carolina Department of Labor Certificate of Inspection, no barracks, fewer residents, no bedroom weather protection or floor violations, and no roaches. Conclusions Farmworkers are exposed to pesticides where they live. Policy on removing pesticides from farmworker houses is needed. Reducing pesticides in farmworker houses will reduce one health risk confronted by this vulnerable population. PMID:24038176

  11. Interannual Variability in Radiative Forcing and Snowmelt Rates by Desert Dust in Snowcover in the Colorado River Basin

    Science.gov (United States)

    Skiles, S.; Painter, T. H.; Barrett, A. P.; Landry, C.; Deems, J. S.; Winstral, A. H.

    2010-12-01

    Dust in snow accelerates snowmelt through its direct reduction of albedo and its further reduction of albedo by accelerating the growth of snow effective grain size. Since the Anglo expansion and disturbance of the western US that began in the mid 19th century, the mountain snow cover of the Colorado River Basin has been subject to five-fold greater dust loading. This research expands on the work done in Painter et al. (2007) by assessing the interannual variability in radiative forcing, melt rates, and shortening of snow cover duration from 2005 to 2010, and the relative response of melt rates to simulated increases in air temperature. We ran the SNOBAL snowmelt model over the 6 year energy balance record at the alpine and subalpine towers in the Senator Beck Basin Study Area, San Juan Mountains, Colorado, USA. Observations indicate that dust concentrations are not correlated with total number of dust events and that dust loading and concentrations vary by an order of magnitude during the 6 year record. Our modeling results indicate that the number of days that dust advances retreat of snow cover and cumulative radiative forcing are linearly related to total dust concentration. Over the 6 years of record we have shown that for all years dust advances melt relative to a clean snowpack, even in lowest dust concentration years melt is advanced by up to 26 days. The greatest dust radiative impact occurred in 2009, when snow cover duration was shortened by 50 days, and the highest observed end of year dust concentrations reduced visible albedo to less than 0.35 during the last three weeks of snowcover. This work also shows that dust radiative forcing has a markedly greater impact on snow cover duration than increases in temperature. In the presence of dust there is little impact from temperature increases of 2 °C and 4 °C (0-4 days) and, in the absence of dust radiative forcing, temperature increases shorten snow cover duration by 5-18 days, compared with the 26

  12. Airborne fungal and bacterial components in PM1 dust from biofuel plants.

    Science.gov (United States)

    Madsen, Anne Mette; Schlünssen, Vivi; Olsen, Tina; Sigsgaard, Torben; Avci, Hediye

    2009-10-01

    Fungi grown in pure cultures produce DNA- or RNA-containing particles smaller than spore size ( 3)-beta-D-glucans. In the 29 PM(1) samples, cultivable fungi were found in six samples and with a median concentration below detection level. Using microscopy, fungal spores were identified in 22 samples. The components NAGase and (1 --> 3)-beta-D-glucans, which are mainly associated with fungi, were present in all PM(1) samples. Thermophilic actinomycetes were present in 23 of the 29 PM(1) samples [average = 739 colony-forming units (CFU) m(-3)]. Cultivable and 'total bacteria' were found in average concentrations of, respectively, 249 CFU m(-3) and 1.8 x 10(5) m(-3). DNA- and RNA-containing particles of different lengths were counted by microscopy and revealed a high concentration of particles with a length of 0.5-1.5 microm and only few particles >1.5 microm. The number of cultivable fungi and beta-glucan in the total dust correlated significantly with the number of DNA/RNA-containing particles with lengths of between 1.0 and 1.5 microm, with DNA/RNA-containing particles >1.5 microm, and with other fungal components in PM(1) dust. Airborne beta-glucan and NAGase were found in PM(1) samples where no cultivable fungi were present, and beta-glucan and NAGase were found in higher concentrations per fungal spore in PM(1) dust than in total dust. This indicates that fungal particles smaller than fungal spore size are present in the air at the plants. Furthermore, many bacteria, including actinomycetes, were present in PM(1) dust. Only 0.2% of the bacteria in PM(1) dust were cultivable.

  13. Improved dust representation in the Community Atmosphere Model

    Science.gov (United States)

    Albani, S.; Mahowald, N. M.; Perry, A. T.; Scanza, R. A.; Zender, C. S.; Heavens, N. G.; Maggi, V.; Kok, J. F.; Otto-Bliesner, B. L.

    2014-09-01

    Aerosol-climate interactions constitute one of the major sources of uncertainty in assessing changes in aerosol forcing in the anthropocene as well as understanding glacial-interglacial cycles. Here we focus on improving the representation of mineral dust in the Community Atmosphere Model and assessing the impacts of the improvements in terms of direct effects on the radiative balance of the atmosphere. We simulated the dust cycle using different parameterization sets for dust emission, size distribution, and optical properties. Comparing the results of these simulations with observations of concentration, deposition, and aerosol optical depth allows us to refine the representation of the dust cycle and its climate impacts. We propose a tuning method for dust parameterizations to allow the dust module to work across the wide variety of parameter settings which can be used within the Community Atmosphere Model. Our results include a better representation of the dust cycle, most notably for the improved size distribution. The estimated net top of atmosphere direct dust radiative forcing is -0.23 ± 0.14 W/m2 for present day and -0.32 ± 0.20 W/m2 at the Last Glacial Maximum. From our study and sensitivity tests, we also derive some general relevant findings, supporting the concept that the magnitude of the modeled dust cycle is sensitive to the observational data sets and size distribution chosen to constrain the model as well as the meteorological forcing data, even within the same modeling framework, and that the direct radiative forcing of dust is strongly sensitive to the optical properties and size distribution used.

  14. Levels of fungi and mycotoxins in the samples of grain and grain dust collected from five various cereal crops in eastern Poland.

    Science.gov (United States)

    Krysińska-Traczyk, Ewa; Perkowski, Juliusz; Dutkiewicz, Jacek

    2007-01-01

    During combine harvesting of 5 various cereal crops (rye, barley, oats, buckwheat, corn) 24 samples of grain and 24 samples of settled grain dust were collected on farms located in the Lublin province of eastern Poland. The samples were examined for the concentration of total microfungi, Fusarium species, deoxynivalenol (DON), nivalenol (NIV), and ochratoxin A (OTA). Microfungi able to grow on malt agar were present in 79.2% of grain samples and in 91.7% of grain dust samples in the concentrations of 1.0-801.3x10(3) cfu/g and 1.5-12440.0x10(3) cfu/g, respectively. The concentration of microfungi in grain dust samples was significantly greater than in grain samples (pgrain samples and from 58.3% of grain dust samples in the concentrations of 0.1-375.0x10(3) cfu/g and 4.0-7,700.0x10(3) cfu/g, respectively. They were found in all samples of grain and grain dust from rye, barley and corn, but only in 0-16.7% of samples of grain and grain dust from oats and buckwheat. DON was found in 79.2% of grain samples and in 100% of grain dust samples in the concentrations of 0.001-0.18 microg/g and 0.006-0.283 microg/g, respectively. NIV was detected in 62.5% of grain samples and in 94.4% of grain dust samples in the concentrations of 0.004-0.502 microg/g and 0.005-0.339 microg/g, respectively. OTA was detected in 58.3% of grain samples and in 91.7% of grain dust samples in the concentrations of 0.00039- 0.00195 microg/g and 0.00036-0.00285 microg/g, respectively. The concentrations of DON, total fusariotoxins (DON+NIV) and OTA were significantly greater in grain dust samples than in grain samples (pgrain and dust was significantly correlated with the concentrations of DON (pgrain and dust was significantly correlated with the concentration of total fusariotoxins (pgrain dust collected from 5 various cereals on farms in eastern Poland was not large, the persistent presence of these mycotoxins in over 90% of examined samples poses a potential health risk of chronic respiratory

  15. Lung macrophages contribute to house dust mite driven airway remodeling via HIF-1α.

    Directory of Open Access Journals (Sweden)

    Adam J Byrne

    Full Text Available HIF-1α is a transcription factor that is activated during hypoxia and inflammation and is a key regulator of angiogenesis in vivo. During the development of asthma, peribronchial angiogenesis is induced in response to aeroallergens and is thought to be an important feature of sustained chronic allergic inflammation. Recently, elevated HIF-1α levels have been demonstrated in both the lung tissue and bronchoalveolar lavage of allergic patients, respectively. Therefore, we investigated the role of HIF-1α on the development of angiogenesis and inflammation following acute and chronic allergen exposure. Our data shows that intranasal exposure to house dust mite (HDM increases the expression of HIF-1α in the lung, whilst reducing the expression of the HIF-1α negative regulators, PHD1 and PHD3. Blockade of HIF-1α in vivo, significantly decreased allergic inflammation and eosinophilia induced by allergen, due to a reduction in the levels of IL-5 and Eotaxin-2. Importantly, HIF-1α blockade significantly decreased levels of VEGF-A and CXCL1 in the lungs, which in turn led to a profound decrease in the recruitment of endothelial progenitor cells and a reduction of peribronchial angiogenesis. Furthermore, HDM or IL-4 treatment of primary lung macrophages resulted in significant production of both VEGF-A and CXCL1; inhibition of HIF-1α activity abrogated the production of these factors via an up-regulation of PHD1 and PHD3. These findings suggest that novel strategies to reduce the expression and activation of HIF-1α in lung macrophages may be used to attenuate allergen-induced airway inflammation and angiogenesis through the modulation of VEGF-A and CXCL1 expression.This study provides new insights into the role of HIF-1α in the development of peribronchial angiogenesis and inflammation in a murine model of allergic airway disease. These findings indicate that strategies to reduce activation of macrophage derived HIF-1α may be used as a target to

  16. Recirculation of Chilean copper smelting dust with high impurities contents to the smelting process

    Energy Technology Data Exchange (ETDEWEB)

    Sano, H.; Fujisawa, T. [Nagoya Univ., Nagoya (Japan). EcoTopia Science Inst.; Montenegro, V. [Nagoya Univ., Nagoya (Japan). Dept. of Materials Science and Engineering

    2007-07-01

    Dust generated during the copper smelting process is generally stabilized using hydrometallurgical methods as it contains high concentrations of arsenic. In this laboratory study, dust was recirculated during the smelting process in order to recover more copper and decrease dust emissions while recovering more copper. The behaviour of impurities and their influence on matte quality was also investigated. Industrial matte, flue dust, slag, and copper concentrates from a Chilean smelter were used as test materials. Dust recirculation tests were conducted in a simulated electric furnace. Off-gases were collected in a reaction tube, and the condensed volatile matter, slag, and matte phases were analyzed for their elemental content by inductively coupled plasma atomic emission spectrometry. The distribution of arsenic (As); antimony (Sb), bismuth (Bi), lead (Pb), and zinc (Zn) were investigated by varying the amounts of dust recirculating to the smelting stage with 21 per cent of the oxygen. Results showed that distributions of all analyzed elements increased with recirculation. It was concluded that copper can be recovered using the dust recirculation technique. However, impurities may limit the efficacy of the dust recirculation process. 6 refs., 3 tabs., 4 figs.

  17. Composition of Trace Metals in Dust Samples Collected from Selected High Schools in Pretoria, South Africa

    Directory of Open Access Journals (Sweden)

    J. O. Olowoyo

    2016-01-01

    Full Text Available Potential health risks associated with trace metal pollution have necessitated the importance of monitoring their levels in the environment. The present study investigated the concentrations and compositions of trace metals in dust samples collected from classrooms and playing ground from the selected high schools In Pretoria. Schools were selected from Pretoria based on factors such as proximity to high traffic ways, industrial areas, and residential areas. Thirty-two dust samples were collected from inside and outside the classrooms, where learners often stay during recess period. The dust samples were analysed for trace metal concentrations using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS. The composition of the elements showed that the concentrations of Zn were more than all other elements except from one of the schools. There were significant differences in the concentrations of trace metals from the schools (p<0.05. Regular cleaning, proximity to busy road, and well maintained gardens seem to have positive effects on the concentrations of trace metals recorded from the classrooms dust. The result further revealed a positive correlation for elements such as Pb, Cu, Zn, Mn, and Sb, indicating that the dust might have a common source.

  18. WRF-Chem Model Simulations of Arizona Dust Storms

    Science.gov (United States)

    Mohebbi, A.; Chang, H. I.; Hondula, D.

    2017-12-01

    The online Weather Research and Forecasting model with coupled chemistry module (WRF-Chem) is applied to simulate the transport, deposition and emission of the dust aerosols in an intense dust outbreak event that took place on July 5th, 2011 over Arizona. Goddard Chemistry Aerosol Radiation and Transport (GOCART), Air Force Weather Agency (AFWA), and University of Cologne (UoC) parameterization schemes for dust emission were evaluated. The model was found to simulate well the synoptic meteorological conditions also widely documented in previous studies. The chemistry module performance in reproducing the atmospheric desert dust load was evaluated using the horizontal field of the Aerosol Optical Depth (AOD) from Moderate Resolution Imaging Spectro (MODIS) radiometer Terra/Aqua and Aerosol Robotic Network (AERONET) satellites employing standard Dark Target (DT) and Deep Blue (DB) algorithms. To assess the temporal variability of the dust storm, Particulate Matter mass concentration data (PM10 and PM2.5) from Arizona Department of Environmental Quality (AZDEQ) ground-based air quality stations were used. The promising performance of WRF-Chem indicate that the model is capable of simulating the right timing and loading of a dust event in the planetary-boundary-layer (PBL) which can be used to forecast approaching severe dust events and to communicate an effective early warning.

  19. Influence of indoor air conditions on radon concentration in a detached house

    International Nuclear Information System (INIS)

    Akbari, Keramatollah; Mahmoudi, Jafar; Ghanbari, Mahdi

    2013-01-01

    Radon is released from soil and building materials and can accumulate in residential buildings. Breathing radon and radon progeny for extended periods hazardous to health and can lead to lung cancer. Indoor air conditions and ventilation systems strongly influence indoor radon concentrations. This paper focuses on effects of air change rate, indoor temperature and relative humidity on indoor radon concentrations in a one family detached house in Stockholm, Sweden. In this study a heat recovery ventilation system unit was used to control the ventilation rate and a continuous radon monitor (CRM) was used to measure radon levels. FLUENT, a computational fluid dynamics (CFD) software package was used to simulate radon entry into the building and air change rate, indoor temperature and relative humidity effects using a numerical approach. The results from analytical solution, measurements and numerical simulations showed that air change rate, indoor temperature and moisture had significant effects on indoor radon concentration. Increasing air change rate reduces radon level and for a specific air change rate (in this work Ach = 0.5) there was a range of temperature and relative humidity that minimized radon levels. In this case study minimum radon levels were obtained at temperatures between 20 and 22 °C and a relative humidity of 50–60%. - Highlights: ► We use CFD to simulate indoor radon concentration and distribution. ► The effects of ventilation rate, temperature and moisture are investigated. ► Model validation is performed through analytical solution and measurement results. ► Results show that ventilation rate is inversely proportional to radon level. ► There is a range of temperature and relative humidity that minimize radon level.

  20. Engineering gravimetric monitoring methods to cope with excessively high dust levels-2.

    CSIR Research Space (South Africa)

    Belle, BK

    1999-11-01

    Full Text Available -test and F-test), the mean dust concentration measured by pairs of cyclones is not significantly affected at 95 percent level of confidence. In other words, there is no difference between the measured mean dust concentration levels between various sampler... List of Figures . . . . . . . 8 List of Tables . . . .. . . 11 Glossary of Abbreviations and Symbols . . . . . 12 Acknowledgements . . . . . . . . 13 1 Introduction . . . . . . . 14 2 Background . . . . . . . 14 3 Test Samplers . . . . . . . 16...

  1. Dust deposition effects on growth and physiology of the endangered Astragalus jaegerianus (Fabaceae)

    Science.gov (United States)

    Wijayratne, Upekala C.; Scoles-Sciulla, Sara J.; Defalco, Lesley A.

    2009-01-01

    Human expansion into the Mojave Desert is a significant threat to rare desert plants. While immediate habitat loss is often the greatest concern, rare plants situated near areas where soil surfaces experience frequent disturbance may be indirectly impacted when fine particulate dust accumulates on leaf surfaces. Remaining populations of the federally listed Astragalus jaegerianus (Lane Mountain milkvetch) occur on land open to expanding military activities and on adjacent public land with increasing recreational use. This study was initiated to determine whether dust accumulation could decrease the vigor and fitness of A. jaegerianus through reduced growth. Beginning in early May 2004, plants located on Bureau of Land Management (BLM) land were dusted bimonthly at canopy-level dust concentrations ranging from 0 to 32 g/m2, and physiology and growth were monitored until late June when plants senesced. The maximum experimental dust level simulates dust concentrations of Mojave Desert perennials neighboring military activities at a nearby army training center. Average shoot growth declined with increasing dust accumulation, but seasonal net photosynthesis increased. Further investigation of plants grown in a greenhouse supported similar trends. This pattern of greater net photosynthesis with increasing dust accumulation may be explained by higher leaf temperatures of dusted individuals. Ambient dust deposition measured in traps near field plants (May 2004–July 2004) ranged from 0.04–0.17 g/m2/ d, which was well below the lowest level of dust on experimental plants (3.95 g/m2/d). With this low level of ambient deposition, we expect that A. jaegerianus plants in this population were not greatly affected by the dust they receive at the level of recreational use during the study.

  2. Uso da poeira e do ar como indicadores de contaminação ambiental em áreas circunvizinhas a uma fonte de emissão estacionária de chumbo Use of dust and air as indicators of environmental pollution in areas adjacent to a source of stationary lead emission

    Directory of Open Access Journals (Sweden)

    Simone Lorena Quiterio

    2001-06-01

    Full Text Available Neste trabalho, determinou-se o nível de chumbo (Pb presente no ar em ambientes externos e na poeira doméstica de residências localizadas próximo a uma reformadora de baterias (RB. Uma das principais fontes de exposição ao Pb são empresas do setor de RB, que ainda utilizam processos e tecnologia obsoletos em instalações precárias. Na área externa à RB foram realizadas coletas em seis pontos localizados a aproximadamente 25m e a 500m da RB. Os resultados obtidos mostram que o limite para Pb no ar atmosférico (Pb-Ar de 1,5µg Pb.m-3 foi excedido em 50% das amostras coletadas, variando de 0,03 a 183,3µg Pb.m-3. As coletas nas dependências internas e externas das residências foram realizadas em seis pontos de quatorze residências localizadas a aproximadamente 25m, 50m e a 500m da RB. O limite de Pb na poeira doméstica (Pb-Pd de 1.500µg Pb.m-2 foi excedido em 44% das amostras coletadas, apresentando valores variáveis de 2,2 a 54.338,9µg Pb.m-2.This study measured lead concentrations in both the outdoor air and household dust from houses located around a lead-acid battery repair shop. Such installations are one of the largest sources of lead exposure, since outdated technology is still used, coupled with the lack of strict air-quality control programs. Measurements of the air lead concentration around the repair shop were carried out at 6 points, approximately 25 and 500m from the shop. Over 50% of the air samples exceeded the limit of 1.5µg Pb.m-3 (range 0.03 - 183.3µg Pb.m-3. House dust samples were collected from 6 places in houses located at approximately 25, 50, and 500m from the repair shop, and the concentration of 1,500µg Pb.m-2 for lead in house dust was exceeded in 44% of the samples, with results varying from 2.2 to 54,338.9µg Pb.m-2.

  3. Dust acoustic shock wave at high dust density

    International Nuclear Information System (INIS)

    Ghosh, Samiran; Sarkar, Susmita; Khan, Manoranjan; Avinash, K.; Gupta, M. R.

    2003-01-01

    Dust acoustic (DA) shock wave at high dust density, i.e., the dust electroacoustic (DEA) or dust Coulomb (DC) shock wave has been investigated incorporating the nonadiabatic dust charge variation. The nonlinear DEA (DC) shock wave is seen to be governed by the Korteweg-de Vries Burger equation, in which the Burger term is proportional to the nonadiabaticity generated dissipation. It is seen that the shock strength decreases but after reaching minimum, it increases as the dust space charge density |q d n d | increases and the shock strength of DA wave is greater than that of DEA (DC) wave. Moreover the DEA (DC) shock width increases appreciably with increase mass m i of the ion component of the dusty plasma but for DA shock wave the effect is weak

  4. An experimental model of allergic asthma in cats sensitized to house dust mite or bermuda grass allergen.

    Science.gov (United States)

    Norris Reinero, Carol R; Decile, Kendra C; Berghaus, Roy D; Williams, Kurt J; Leutenegger, Christian M; Walby, William F; Schelegle, Edward S; Hyde, Dallas M; Gershwin, Laurel J

    2004-10-01

    Animal models are used to mimic human asthma, however, not all models replicate the major characteristics of the human disease. Spontaneous development of asthma with hallmark features similar to humans has been documented to occur with relative frequency in only one animal species, the cat. We hypothesized that we could develop an experimental model of feline asthma using clinically relevant aeroallergens identified from cases of naturally developing feline asthma, and characterize immunologic, physiologic, and pathologic changes over 1 year. House dust mite (HDMA) and Bermuda grass (BGA) allergen were selected by screening 10 privately owned pet cats with spontaneous asthma using a serum allergen-specific IgE ELISA. Parenteral sensitization and aerosol challenges were used to replicate the naturally developing disease in research cats. The asthmatic phenotype was characterized using intradermal skin testing, serum allergen-specific IgE ELISA, serum and bronchoalveolar lavage fluid (BALF) IgG and IgA ELISAs, airway hyperresponsiveness testing, BALF cytology, cytokine profiles using TaqMan PCR, and histopathologic evaluation. Sensitization with HDMA or BGA in cats led to allergen-specific IgE production, allergen-specific serum and BALF IgG and IgA production, airway hyperreactivity, airway eosinophilia, an acute T helper 2 cytokine profile in peripheral blood mononuclear cells and BALF cells, and histologic evidence of airway remodeling. Using clinically relevant aeroallergens to sensitize and challenge the cat provides an additional animal model to study the immunopathophysiologic mechanisms of allergic asthma. Chronic exposure to allergen in the cat leads to a variety of immunologic, physiologic, and pathologic changes that mimic the features seen in human asthma.

  5. Trace-element concentrations and water-soluble ions in size-segregated dust-borne and soil samples in Sistan, southeast Iran

    Science.gov (United States)

    Behrooz, Reza Dahmardeh; Esmaili-Sari, Abbas; Bahramifar, Nader; Kaskaoutis, D. G.; Saeb, Keivan; Rajaei, Fatemeh

    2017-04-01

    This study analyzes the chemical composition (water-soluble ions and trace elements) of the total suspended particles (TSP) and particulate matter less than 10 and 2.5 μm (PM10 and PM2.5) in the Sistan basin, southeast Iran during the dusty and windy period June - October 2014. Extreme TSP, PM10 and PM2.5 concentrations, means of 1624.8, 433.4 and 320.8 μgm-3, respectively, were recorded in the Zabol sampling site, while the examined water-soluble ions and trace metals constitute small fractions (∼4.1%-17.7%) of the particulate masses. Intense winds on the dust-storm days result in weathering of soil crust and deflation of evaporate minerals from the dried Hamoun lake beds in the Sistan basin. The soil samples are rich in Ca2+, SO42-, Na+ and Cl- revealing the existence of non-sea salts, as well as in Al, Fe and Mg, while the similarity in the chemical composition between soil and airborne samples indicates that the dust events over Sistan are local in origin. In contrast, low concentrations of secondary ions (i.e., nitrate) and heavy metals (i.e., Pb, Cr, Ni, Cu) indicate less anthropogenic and industrial emissions. Enrichment Factor analysis for TSP, PM10 and PM2.5 reveals that the anthropogenic sources contribute a substantial amount in the heavy metals rather than soil crust, while Al, Fe, Sn, Mg are mostly of crustal origin. The results provide essential knowledge in atmospheric chemistry over Sistan and in establishing mitigation strategies for air pollution control.

  6. Dust Dynamics Near Planetary Surfaces

    Science.gov (United States)

    Colwell, Joshua; Hughes, Anna; Grund, Chris

    streams observed by Apollo astronauts and potentially also by the Clementine spacecraft. In addition to the Surveyor images of lunar horizon glow and the high altitude streamer measurements, the Apollo 17 Lunar Ejecta and Meteorite surface package detected signals consistent with the impact of relatively slow-moving dust particles that may have been charged dust electrostatically levitated from the surface. There is renewed interest in this near-surface dust environment with plans to return robotic landers and astronauts to the lunar surface. No Apollo-era instruments were specifically designed to detect or measure dust levitated off the lunar surface. One new experiment under study is the Autonomous Lunar Dust Observer (ALDO). ALDO is a high-sensitivity scanning lidar (laser radar) that autonomously maps and records its 3-D dust environment. Flexibility of programmable scan pattern enables ALDO to characterize the dust context in and around experiment sites. Repeated shallow angle scans in a vertical plane enable high vertical resolution studies of dust levitation near the ground. Single elevation angle sector or full azimuth scans enable large-area statistical surveys of the frequency and size of ejecta plumes from micrometeoroid impacts, and vertical or fixed-angle stares enable very high sensitivity dust profiles to extended ranges. It is estimated that backscatter from dust concentrations as low as 1/cm3 can be measured. The concept is equally applicable to surface and atmospheric studies of other airless bodies.

  7. Simulation and analysis of synoptic scale dust storms over the Arabian Peninsula

    Science.gov (United States)

    Beegum, S. Naseema; Gherboudj, Imen; Chaouch, Naira; Temimi, Marouane; Ghedira, Hosni

    2018-01-01

    Dust storms are among the most severe environmental problems in arid and semi-arid regions of the world. The predictability of seven dust events, viz. D1: April 2-4, 2014; D2: February 23-24, 2015; D3: April 1-3, 2015; D4: March 26-28, 2016; D5: August 3-5, 2016; D6: March 13-14, 2017 and D7:March 19-21, 2017, are investigated over the Arabian Peninsula using a regionally adapted chemistry transport model CHIMERE coupled with the Weather Research and Forecast (WRF) model. The hourly forecast products of particulate matter concentrations (PM10) and aerosol optical depths (AOD) are compared against both satellite-based (MSG/SEVRI RGB dust, MODIS Deep Blue Aerosol Optical Depth: DB-AOD, Ozone Monitoring Instrument observed UV Aerosol Absorption Index: OMI-AI) and ground-based (AERONET AOD) remote sensing products. The spatial pattern and the time series of the simulations show good agreement with the observations in terms of the dust intensity as well as the spatiotemporal distribution. The causative mechanisms of these dust events are identified by the concurrent analyses of the meteorological data. From these seven storms, five are associated with synoptic scale meteorological processes, such as prefrontal storms (D1 and D7), postfrontal storms of short (D2), and long (D3) duration types, and a summer shamal storm (D6). However, the storms D4 and D6 are partly associated with mesoscale convective type dust episodes known as haboobs. The socio-economic impacts of the dust events have been assessed by estimating the horizontal visibility, air quality index (AQI), and the dust deposition flux (DDF) from the forecasted dust concentrations. During the extreme dust events, the horizontal visibility drops to near-zero values co-occurred withhazardous levels of AQI and extremely high dust deposition flux (250 μg cm- 2 day- 1).

  8. Systematic characterization of structural, dynamical and electrical properties of dust devils and implications for dust lifting processes

    Science.gov (United States)

    Franzese, Gabriele; Esposito, Francesca; Lorenz, Ralph D.; Popa, Ciprian; Silvestro, Simone; Deniskina, Natalia; Cozzolino, Fabio

    2017-04-01

    Dust devils are convective vortices able to lift sand and dust grains from the soil surface, even in conditions of low wind speed environment. They have been observed not only on Earth but also on other planets of the solar system; in particular, they are largely studied on Mars. Indeed, the contribution of the dust devils to the Martian climate is a highly debated question. In order to investigate this topic, it is important to understand the nature of the dust lifting mechanism by the vortex and characterize the induced electric field. As part of the development process of DREAMS, the meteorological station on board the Schiapparelli lander of the ExoMars 2016 mission, and of the Dust complex package of the ExoMars 2020 mission, we performed various field campaigns in the Sahara desert (Tafilalt region, Morocco). We deployed a fully equipped meteorological station and, during the 2014 summer, we observed three months of dust devils activity, collecting almost six hundreds events. For each dust devil, we monitored the horizontal wind speed and direction, the vertical wind speed, the pressure drop due to the vortex core, the temperature, the induced electric field and the concentration of dust lifted. This data set is unique in literature and represents up to now the most comprehensive one available for the dusty convective vortices. Here we will present the analysis of the Moroccan data with particular emphasis on the study of the atmospheric electric field variations due to the passage of the vortices. The distribution of the vortex parameters (wind speed and direction, pressure, E-field and dust lifted) are showed and compared, when possible, to the ones observed by the Martian surveys. The connection between the E-field and the other parameters will be presented. In the terrestrial environment, the development of the convective vortices is restricted by the presence of the vegetation and of the urban areas, hence dust devils can impact the climate only on local

  9. Injurious effects of wool and grain dusts on alveolar epithelial cells and macrophages in vitro.

    Science.gov (United States)

    Brown, D M; Donaldson, K

    1991-01-01

    Epidemiological studies of workers in wool textile mills have shown a direct relation between the concentration of wool dust in the air and respiratory symptoms. Injurious effects of wool dust on the bronchial epithelium could be important in causing inflammation and irritation. A pulmonary epithelial cell line in vitro was therefore used to study the toxic effects of wool dust. Cells of the A549 epithelial cell line were labelled with 51Cr and treated with whole wool dusts and extracts of wool, after which injury was assessed. Also, the effects of grain dust, which also causes a form of airway obstruction, were studied. The epithelial injury was assessed by measuring 51Cr release from cells as an indication of lysis, and by monitoring cells which had detached from the substratum. No significant injury to A549 cells was caused by culture with any of the dusts collected from the air but surface "ledge" dust caused significant lysis at some doses. Quartz, used as a toxic control dust, caused significant lysis at the highest concentration of 100 micrograms/well. To determine whether any injurious material was soluble the dusts were incubated in saline and extracts collected. No extracts caused significant injury to epithelial cells. A similar lack of toxicity was found when 51Cr labelled control alveolar macrophages were targets for injury. Significant release of radiolabel was evident when macrophages were exposed to quartz at concentrations of 10 and 20 micrograms/well, there being no significant injury with either wool or grain dusts. These data suggest that neither wool nor grain dust produce direct injury to epithelial cells, and further studies are necessary to explain inflammation leading to respiratory symptoms in wool and grain workers. PMID:2015211

  10. Airborne dust distribution in a farrowing pen in dependence of other microclimatic parameters during spring-summer period

    Directory of Open Access Journals (Sweden)

    Boris Antunović

    2010-01-01

    Full Text Available The study was carried out in a farrowing pen during 6 production cycles of 24 days in the spring-summer period. The effect of season and other microclimate parameters on airborne dust concentration was investigated. Study results showed a decrease in airborne dust concentration in summer period that yielded negative correlation with air temperature (P<0.05. Relative humidity was expected to decrease due to higher ventilation rates, however, a significant increase was recorded in summer (P<0.05 because of higher evaporation caused by floor wash. The decrease in airborne dust concentration was ascribed to temperature elevation due to intensified ventilation rate and relative humidity resulting in higher rate of dust settling.

  11. The association between phthalates in dust and allergic diseases among Bulgarian children

    DEFF Research Database (Denmark)

    Kolarik, Barbara; Naydenov, Kiril Georgiev; Larsson, Martin

    2008-01-01

    BACKGROUND: Recent studies have identified associations between the concentration of phthalates in indoor dust and allergic symptoms in the airways, nose, and skin. OBJECTIVES: Our goal was to investigate the associations between allergic symptoms in children and the concentration of phthalate...... (controls). The dust samples were analyzed for their content of dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DnBP), butyl benzyl phthalate (BBzP), di(2-ethylhexyl) phthalate (DEHP), and di-n-octyl phthalate (DnOP). RESULTS: A higher concentration of DEHP was found in homes...

  12. Determinants of wood dust exposure in the Danish furniture industry.

    Science.gov (United States)

    Mikkelsen, Anders B; Schlunssen, Vivi; Sigsgaard, Torben; Schaumburg, Inger

    2002-11-01

    This paper investigates the relation between wood dust exposure in the furniture industry and occupational hygiene variables. During the winter 1997-98 54 factories were visited and 2362 personal, passive inhalable dust samples were obtained; the geometric mean was 0.95 mg/m(3) and the geometric standard deviation was 2.08. In a first measuring round 1685 dust concentrations were obtained. For some of the workers repeated measurements were carried out 1 (351) and 2 weeks (326) after the first measurement. Hygiene variables like job, exhaust ventilation, cleaning procedures, etc., were documented. A multivariate analysis based on mixed effects models was used with hygiene variables being fixed effects and worker, machine, department and factory being random effects. A modified stepwise strategy of model making was adopted taking into account the hierarchically structured variables and making possible the exclusion of non-influential random as well as fixed effects. For woodworking, the following determinants of exposure increase the dust concentration: manual and automatic sanding and use of compressed air with fully automatic and semi-automatic machines and for cleaning of work pieces. Decreased dust exposure resulted from the use of compressed air with manual machines, working at fully automatic or semi-automatic machines, functioning exhaust ventilation, work on the night shift, daily cleaning of rooms, cleaning of work pieces with a brush, vacuum cleaning of machines, supplementary fresh air intake and safety representative elected within the last 2 yr. For handling and assembling, increased exposure results from work at automatic machines and presence of wood dust on the workpieces. Work on the evening shift, supplementary fresh air intake, work in a chair factory and special cleaning staff produced decreased exposure to wood dust. The implications of the results for the prevention of wood dust exposure are discussed.

  13. Cometary Dust

    Science.gov (United States)

    Levasseur-Regourd, Anny-Chantal; Agarwal, Jessica; Cottin, Hervé; Engrand, Cécile; Flynn, George; Fulle, Marco; Gombosi, Tamas; Langevin, Yves; Lasue, Jérémie; Mannel, Thurid; Merouane, Sihane; Poch, Olivier; Thomas, Nicolas; Westphal, Andrew

    2018-04-01

    This review presents our understanding of cometary dust at the end of 2017. For decades, insight about the dust ejected by nuclei of comets had stemmed from remote observations from Earth or Earth's orbit, and from flybys, including the samples of dust returned to Earth for laboratory studies by the Stardust return capsule. The long-duration Rosetta mission has recently provided a huge and unique amount of data, obtained using numerous instruments, including innovative dust instruments, over a wide range of distances from the Sun and from the nucleus. The diverse approaches available to study dust in comets, together with the related theoretical and experimental studies, provide evidence of the composition and physical properties of dust particles, e.g., the presence of a large fraction of carbon in macromolecules, and of aggregates on a wide range of scales. The results have opened vivid discussions on the variety of dust-release processes and on the diversity of dust properties in comets, as well as on the formation of cometary dust, and on its presence in the near-Earth interplanetary medium. These discussions stress the significance of future explorations as a way to decipher the formation and evolution of our Solar System.

  14. Foehn-induced effects on dust pollution, frontal clouds and solar radiation in the Dead Sea valley

    Science.gov (United States)

    Kishcha, Pavel; Starobinets, Boris; Alpert, Pinhas; Kaplan, Michael

    2017-04-01

    The significant drying up of the Dead Sea over the past 40 years has led to an increase in an exposed area contributing to local dust pollution. Measurements show that, sometimes, in the Dead Sea valley, dust pollution can reach extreme concentrations up to several thousands of micrograms per cubic meters. Our analysis of a meteorological situation shows that a foehn phenomenon can be a causal factor for the aforementioned extreme local dust concentration. This foehn phenomenon creates strong warm and dry winds, which are accompanied by air turbulence and temperature inversion. In our study, foehn-induced effects on dust pollution, frontal clouds and solar radiation were analyzed over the Judean Mountains ( 1000 m) and over the Dead Sea valley (-420 m), using high-resolution numerical simulations and in-situ observations at meteorological stations located across the mountain ridge. An extreme dust episode occurring on March 22, 2013, was analyzed, which was characterized by measured surface dust concentrations of up to 7000 µg m-3 in the Dead Sea valley. We simulated this foehn phenomenon with the 3-km resolution COSMO-ART model. Our analysis has shown that the foehn phenomenon could be observed even over the relatively low Judean Mountains. This analysis was based on various meteorological, pyranometer, radar, and aerosol measurements together with high-resolution model data. In the Dead Sea valley, the maximum aerosol optical depth (AOD) did not coincide with the maximum surface dust concentration. This lack of coincidence indicates difficulties in using satellite-based AOD for initializing dust concentration within numerical forecast systems over this region with complex terrain. In the western Dead Sea valley, strong foehn winds of over 20 m/s were accompanied by maximal air turbulence leading to maximal local dust emissions. Thus, the model showed that, by creating significant turbulence, the foehn phenomenon intensified the saltation (bombardment) mechanism

  15. Effect of two doses of carbamylated allergoid extract of dust mite on nasal reactivity.

    Science.gov (United States)

    Scalone, G; Compalati, E; Bruno, M E; Mistrello, G

    2013-11-01

    Background and Objective. Single SLIT studies with native allergen extracts support a dose-response effect for clinical and immunological outcomes. Conversely for carbamylated allergoids this dose-response effects is less evident, likely because the threshold for efficacy is more easily reached through the enhanced bioavailability of the extract consequent to the selective chemical modification. Thus this pilot study investigates the dose-response effect on nasal specific reactivity and safety of two unusual doses of carbamylated allergoid in patients mono-sensitized to house dust mites. Methods. A prospective open randomized study involved 6-65 year-old Italian patients with clinically relevant sensitization to house dust mites and positive response to nasal provocation challenge. Monomeric carbamylated allergoid was delivered once daily at the dose of 1000 AU or 2000 AU from June to September 2009, during the lowest level of mites exposure. Primary outcomes were the change of the threshold of allergen concentration for a positive nasal provocation test (NPT) before and after the treatment and the product safety. Secondary outcome was the change  in the mean percentage fall of peak nasal inspiratory flow (PNIF) following nasal challenge. Results. Thirty-four patients were enrolled. Fifteen in group 1 and 14 in group 2 concluded the study. After 12 weeks all patients treated in group 1 and all but one in group 2 showed an increase in the threshold dose provoking a positive NPT. Those with no symptoms onset with the highest dose delivered were 80% in group 1 and 78.6% in group 2 (p=0.92). From first to second challenge, the mean percentage fall of PNIF  was reduced with no statistical difference between groups (p=0.95), and with no difference between the final mean percentage falls (p=0.65). No serious adverse reactions occurred and the frequency of events, all mild, was similar in the two groups. Conclusions. Twelve weeks of carbamylated sublingual allergoid

  16. Radiation dose to workers due to the inhalation of dust during granite fabrication

    International Nuclear Information System (INIS)

    Zwack, L M; Stewart, J H; McCarthy, J F; Allen, J G; McCarthy, W B

    2014-01-01

    There has been very little research conducted to determine internal radiation doses resulting from worker exposure to ionising radiation in granite fabrication shops. To address this issue, we estimated the effective radiation dose of granite workers in US fabrication shops who were exposed to the maximum respirable dust and silica concentrations allowed under current US regulations, and also to concentrations reported in the literature. Radiation doses were calculated using standard methods developed by the International Commission on Radiological Protection. The calculated internal doses were very low, and below both US occupational standards (50 mSv yr −1 ) and limits applicable to the general public (1 mSv yr −1 ). Workers exposed to respirable granite dust concentrations at the US Occupational Safety and Health Administration (OSHA) respirable dust permissible exposure limit (PEL) of 5 mg m −3 over a full year had an estimated radiation dose of 0.062 mSv yr −1 . Workers exposed to respirable granite dust concentrations at the OSHA silica PEL and at the American Conference of Governmental Industrial Hygienists Threshold Limit Value for a full year had expected radiation doses of 0.007 mSv yr −1 and 0.002 mSv yr −1 , respectively. Using data from studies of respirable granite dust and silica concentrations measured in granite fabrication shops, we calculated median expected radiation doses that ranged from <0.001 to 0.101 mSv yr −1 . (paper)

  17. Building-related symptoms and inflammatory potency of dust from office buildings

    DEFF Research Database (Denmark)

    Allermann, L; Pejtersen, J; Gunnarsen, L

    2007-01-01

    UNLABELLED: The aim was to investigate the association between building-related symptoms (BRS) in office buildings and the inflammatory potency of dust (PD). Furthermore, the association between dust potency and various building characteristics was investigated. Occupants of 22 office buildings...... received a retrospective questionnaire about BRS (2301 respondents). Dust was collected from groups of offices and building characteristics were recorded. The potency of a dust sample to induce interleukin-8 (IL-8) secretion from the lung epithelial cell line A549 was measured as the slope of the initial...... linear part of the concentration-response curve. Symptoms of the central nervous system (CNS) were associated with the potency of surface dust (OR = 1.4). This association may be due to an association between an index of CNS symptoms and dust potency in offices of 1-6 occupants (OR = 1.5). No single...

  18. The accumulation of dust mite allergens on mattresses made of different kinds of materials.

    Science.gov (United States)

    Visitsunthorn, Nualanong; Chirdjirapong, Varakorn; Pootong, Visanu; Jirapongsananuruk, Orathai; Pacharn, Punchama; Weeravejsukit, Sirirat; Mahakittikun, Vanna; Vichyanond, Pakit

    2010-01-01

    Different mattress materials may affect the accumulation of allergens. To compare the amount of group 1 dust mite allergens (Der p1 + Der f1) on mattresses made of different kinds of materials before and after use. Sixty new mattresses made of kapok, synthetic fiber, coconut fiber and sponge-like polyurethane, were placed in the house officers' dormitory at Siriraj hospital, Thailand. The dust samples were collected before (0), 1, 2, 3, 6, 9 and 12 months after the mattresses were used. Group 1 dust mite allergens were analyzed using two-site monoclonal antibody ELISA. Der f1 made up 86.7 % of group 1 allergens found in the matress dust. After the 2nd month, only the mean level in sponge-like polyurethane mattress was under 2 microg/g dust (sensitized level). At the 6th month, the mean levels were 13.1 in coconut, 21.7 in kapok and 17.3 microg/g dust in synthetic fiber, all of which were more than 10 microg/g dust (symptomatic level). At the 9th month, the level in sponge-like polyurethane mattress was increased to 11.2 microg/g. At 12th month the level in coconut fiber, sponge-like polyurethane synthetic fiber and kapok mattresses were 20.2, 22.4, 28.9 and 32.2 microg/g dust respectively. The accumulation rate in kapok and synthetic mattresses was significantly higher than coconut and sponge-like polyurethane mattresses. The mean level of group 1 mite allergens exceeded 10 microg/g dust after the 6th month of use in coconut fiber, kapok and synthetic fiber and at the 9th month in sponge-like polyurethane mattress.

  19. Diagnosis and evaluation of fungi presence in the air of two different ventilation sytems for broiler houses

    Directory of Open Access Journals (Sweden)

    ACS Gigli

    2005-12-01

    Full Text Available Intensive broiler production in tropical climates requires adequate air circulation to control heat stress. Excess of air speed may lead to dust production and reduction of air quality and, consequently, production parameters. Brazilian regulations prohibit the presence of pathogens that may deteriorate air quality, and the presence of fungi in the air inside the poultry houses is limited to 750CFU/m³. The aim of this study was to evaluate the presence of fungi in two distinct types of broiler houses. The research compared two types of air ventilation: conventional (G1 and positive tunnel ventilation (G2. The fungi were collected using a dust sampling pump, with the air flow calibrated to 1.5 L/min. The filter impregnated with dust was submitted to growth for two days using five Petri dishes. Microbiology analysis showed that there were 1,239 CFU and 2,011 CFU in G1 and G2, respectively. The different genera of fungi found and their percentages were: Penicillium 29.16%, Aspergillus 37.5% and Fusarium 29.16% in G1 and Penicillium 33.34%, Aspergillus 26.64%, Fusarium 23.34% and Neurospora 3.34% in G2.

  20. Evaluation of the concentration of allergens from mites in fur and households dust of dogs with atopic dermatitis

    Directory of Open Access Journals (Sweden)

    Dévaki L. de Assunção

    Full Text Available ABSTRACT: This study evaluated the concentration of Der p 1, Der f 1 and Blo t 5 in the fur and households of 20 dogs with atopic dermatitis (AD and 20 healthy dogs. The diagnosis of AD was clinical based on Favrot’s criteria. Dust samples were collected with a domestic vacuum cleaner. For each site, 1m2 was vacuumed for 2 min. The samples were collected in separate filters, transferred into plastic containers, sealed and kept frozen until ELISA analysis. In the fur of atopic dogs the average concentration of Der p 1 was 0.25μg/g compared to 0.03μg/g in healthy dogs. In households with atopic dogs the highest concentrations of Der p 1 were found in carpets (2.18μg/g, followed by couches (1.53μg/g, beds (1.14μg/g, dogs’ bed linen (0.64μg/g and floors (0.14μg/g. The concentrations of Der p 1 on carpets, couches and beds were significantly higher than in atopic dogs’ fur (p0.05. The concentrations of Der p 1, Der f 1 and Blo t 5 were equivalent in atopic and non-atopic dog’s households. Among the allergens studied, Der p 1 was the most commonly found, predominantly in carpets and couches.