WorldWideScience

Sample records for hot flue gas

  1. Diatomaceous earth and activated bauxite used as granular sorbents for the removal of sodium chloride vapor from hot flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.H.D.; Swift, W.M.; Johnson, I.

    1980-01-01

    Diatomaceous earth and activated bauxite were tested as granular sorbents for use as filter media in granular-bed filters for the removal of gaseous alkali metal compounds from the hot (800/sup 0/C) flue gas of PFBC. Tests were performed at atmospheric pressure, using NaCl vapor transported in relatively dry simulated flue gas of PFBC. Either a fixed-bed combustor or a high-temperature sorption test rig was used. The effects of sorbent bed temperature, superficial gas velocity, gas hourly space velocity, and NaCl-vapor concentration in flue gas on the sorption behavior of these two sorbents and their ultimate sorption capacities were determined. Both diatomaceous earth and activated bauxite were found to be very effective in removing NaCl vapor from flue gas. Preliminary cost evaluations showed that they are economically attractive as granular sorbents for cleaning alkali vapor from simulated flue gas.

  2. Hot gas filtration: Investigations to remove gaseous pollutant components out of flue gas during hot gas filtration. Final report; HGR: Untersuchung zur Minimierung von gasfoermigen Schadstoffen aus Rauchgasen bei der Heissgasfiltration. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Christ, A; Gross, R; Renz, U

    1998-07-01

    Power plants with gas and steam turbines in pressurized fluidized bed or pressurized gasification processes enable power generation of coal with high efficiency and little emissions. To run these plants the cleaning of the flue gas is necessary before entering the turbines under the conditions of high temperature and pressure. Ceramic filter elements are the most probable method for hot gas cleaning. A simultaneous reduction of gaseous pollutant components under these conditions could help to make the whole process more efficient. The aim of the project is to integrate the catalytic reduction of carbon monoxide, hydrocarbons and nitric oxides into the hot gas filtration with ceramic filter elements as a one step mecanism. The project is focused on: - the catalytic behaviour of ferruginous ashes of brown coal, - the effectiveness of calcinated aluminates as a catalyst to remove uncombusted hydrocarbons in a hot gas filtration unit, - numerical simulation of the combined removal of particles and gaseous pollutant components out of the flue gas. (orig.) [Deutsch] Gas- und Dampfturbinen-Kraftwerke mit Druckwirbelschicht- oder mit Druckvergasungsverfahren ermoeglichen die Verstromung von Kohle mit hohem Wirkungsgrad und niedrigen Emissionen. Eine Voraussetzung fuer den Betrieb dieser Anlagen ist die Entstaubung der Rauchgase bei hohen Temperaturen und Druecken. Abreinigungsfilter mit keramischen Elementen werden dazu eingesetzt. Eine Reduzierung gasfoermiger Schadstoffe unter den gleichen Bedingungen koennte die Rauchgaswaesche ersetzen. Ziel des Gesamtvorhabens ist es, die Integration von Heissgasfiltration und katalytischem Abbau der Schadstoffe Kohlenmonoxid, Kohlenwasserstoffe und Stickoxide in einem Verfahrensschritt zu untersuchen. Die Arbeitsschwerpunkte dieses Teilvorhabens betreffen - die katalytische Wirkung eisenhaltiger Braunkohlenaschen, - die Wirksamkeit des Calciumaluminats als Katalysator des Abbaus unverbrannter Kohlenwasserstoffe im Heissgasfilter

  3. System of treating flue gas

    International Nuclear Information System (INIS)

    Ziegler, D.L.

    1975-01-01

    A system is described for treating or cleaning incinerator flue gas containing acid gases and radioactive and fissionable contaminants. Flue gas and a quench solution are fed into a venturi and then tangentially into the lower portion of a receptacle for restricting volumetric content of the solution. The upper portion of the receptacle contains a scrub bed to further treat or clean the flue gas

  4. Evaluation of a flue gas driven open absorption system for heat and water recovery from fossil fuel boilers

    International Nuclear Information System (INIS)

    Wang, Zhenying; Zhang, Xiaoyue; Li, Zhen

    2016-01-01

    Highlights: • Flue gas driven open absorption system that efficiently recovers total heat. • Efficient heat and water recovery for various kinds of fossil fuel boilers. • Heat and water recovery efficiencies increase with moisture content of flue gas. • Temperature requirements for district heat supply and domestic hot water were met. • Experimental system surpasses conventional condensing system in total heat recovery. - Abstract: This paper presents an open absorption system for total heat recovery from fossil fuel boilers using the high temperature flue gas as the regeneration heat source. In this system, liquid desiccant serves as the recycling medium, which absorbs waste heat and moisture contained in the low temperature flue gas in the packed tower and then regenerates in the regenerator by the high temperature flue gas. Water vapor generated in the regenerator gets condensed after releasing heat to the heating water system and the condensing water also gets recycled. The return water collects heat from the solution water heat exchanger, the flue gas water heat exchanger and the condenser respectively and is then used for district heating. Driven by the vapor pressure difference between high humidity flue gas and the liquid desiccant, the heat recovery efficiency of the system is not limited by the dew point of the flue gas, enabling a warmer water to be heated up than the conventional condensing boiler. The performance of this system was analyzed theoretically and experimentally and the results showed that the system operated well for both district heat supply and domestic hot water supply. The system efficiency increased with the moisture content of flue gas and the total heat recovery was about 8.5%, 17.2%, 21.2%, and 9.2% higher than the conventional condensing system in the case of coal fired boiler, fuel oil boiler, natural gas boiler, and coke oven gas boiler, respectively.

  5. Process for catalytic flue gas denoxing

    International Nuclear Information System (INIS)

    Woldhuis, A.; Goudriaan, F.; Groeneveld, M.; Samson, R.

    1991-01-01

    With the increasing concern for the environment, stringency of legislation and industry's awareness of its own environmental responsibility, the demand for the reduction of emission levels of nitrogen oxides is becoming increasingly urgent. This paper reports that Shell has developed a low temperature catalytic deNOx system for deep removal of nitrogen oxides, which includes a low-pressure-drop reactor. This process is able to achieve over 90% removal of nitrogen oxides and therefore can be expected to meet legislation requirements for the coming years. The development of a low-temperature catalyst makes it possible to operate at temperatures as low as 120 degrees C, compared to 300-400 degrees C for the conventional honeycomb and plate-type catalysts. This allows an add-on construction, which is most often a more economical solution than the retrofits in the hot section required with conventional deNOx catalysts. The Lateral Flow Reactor (LFR), which is used for dust-free flue gas applications, and the Parallel Passage Reactor (PPR) for dust-containing flue gas applications, have been developed to work with pressure drops below 10 mbar

  6. Water recovery from flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Heijboer, R.; Van Deelen-Bremer, M.H.; de Vos, F.; Zeijseink, A.G.L. [KEMA Nederland B.V. (Netherlands)

    2007-07-01

    In the power generation process a large amount of water is needed, for steam generation, flue gas cleaning etc. On the other hand a large amount of water is emitted to the atmosphere via the stack. For example a 400 MW coal fired power plant with a flue gas desulfurisation plant emits about 1,500,000 m{sup 3} per hour with a water concentration of about 11%. The emitted water has a rather good quality compared to surface water and needs less effort to be treated for use as make-up water. As the available amount of water in the flue gas from the earlier mentioned power plant is about 150 tons per hour, recovering 20% of this amount covers the make-up water needs of this 400 MW power plant. Direct condensation of the flue gas needs large cooling power and the condensed water is acidic and corrosive and needs cleanup treatment before it can be used in the water/steam cycle. KEMA developed a technology based on gas separation membranes which makes it possible to recover water from flue gas. The process is covered by a wide patent. The principle of the membrane is comparable to the material that is used in fabric like SympaTex{reg_sign} and GORE-TEX{reg_sign}. The GORE-TEX material is permeable to water vapor but rejects liquid water. The driving force is the water vapor pressure close to the human skin which is the higher than the water vapor pressure open the outside of the clothing. The selectivity of the GORE-TEX material however is not good enough to be used at the temperature of flue gas. The University of Twente (Netherlands) developed a membrane material based on modified PEEK which is highly selective of water vapor at flue gas temperatures. Based on the fact that flat membranes have an uneconomical surface to volume ratio, the choice has been made to use hollow fibre membranes. 6 figs.

  7. Fundamental mechanisms in flue gas conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, T.R.; Vann Bush, P. [Southern Research Institute, Birmingham, AL (United States)

    1995-11-01

    The overall goal of this research project has been to formulate a model describing effects of flue gas conditioning on particulate properties. By flue gas conditioning we mean any process by which solids, gases, or liquids are added to the combustor and/or the exhaust stream to the extent that flue gas and particulate properties may be altered. Our modeling efforts, which are included in our Final Report, are based on an understanding of how ash properties, such as cohesivity and resistivity, are changed by conditioning. Flue gas conditioning involves the modification of one or more of the parameters that determine the magnitude of forces acting on the fly ash particles, and can take place through many different methods. Modification of particulate properties can alter ash resistivity or ash cohesivity and result in improved or degraded control device performance. Changes to the flue gas, addition or particulate matter such as flue gas desulfurization (FGD) sorbents, or the addition of reactive gases or liquids can modify these properties. If we can better understand how conditioning agents react with fly ash particles, application of appropriate conditioning agents or processes may result in significantly improved fine particle collection at low capital and operating costs.

  8. ABB wet flue gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Niijhawan, P.

    1994-12-31

    The wet limestone process for flue gas desulfurization (FGD) is outlined. The following topics are discussed: wet flue gas desulfurization, wet FGD characteristics, wet scrubbers, ABB wet FGD experience, wet FGD forced oxidation, advanced limestone FGD systems, key design elements, open spray tower design, spray tower vs. packed tower, important performance parameters, SO{sub 2} removal efficiency, influence by L/G, limestone utilization, wet FGD commercial database, particulate removal efficiencies, materials of construction, nozzle layout, spray nozzles, recycle pumps, mist elimination, horizontal flow demister, mist eliminator washing, reagent preparation system, spray tower FGDS power consumption, flue gas reheat options, byproduct conditioning system, and wet limestone system.

  9. Biological flue gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Buisman, C.J.N.; Dijkman, H.; Wijte, G.; Prins, W.L.; Verbraak, P.; Hartog, H.A.J. den [Paper B.V. Blak (Netherlands)

    1995-08-01

    A new biological flue gas desulfurization process (BIO-FGD) producing sulphur as a by-product was invented by Paques BV and Hoogens Technical Services in 1993. Sulphur dioxide is absorbed from flue gas using a combination of a sodium based scrubber and two biological reactors, an anaerobic and an aerobic biological reactor. The article describes the process and its evaluation in a pilot plant at 2 MW scale, designed to remove 6 kg/hr SO{sub 2} of the 2 million m{sup 3}/hr of flue gas produced at the 600 MW coal fired power station Amer-8 situated in Geertruidenberg in the south of the Netherlands. Research so far has proved the process works successfully and at low cost. A second pilot plant due to start-up in May 1995 will provide data on scale up and further information on sulphur recovery. 5 refs., 5 figs.

  10. System and method for treatment of a flue gas

    Science.gov (United States)

    Spiry, Irina Pavlovna; Wood, Benjamin Rue; Singh, Surinder Prabhjot; Perry, Robert James; McDermott, John Brian

    2017-09-19

    A method for treatment of a flue gas involves feeding the flue gas and a lean solvent to an absorber. The method further involves reacting the flue gas with the lean solvent within the absorber to generate a clean flue gas and a rich solvent. The method also involves feeding the clean flue gas from the absorber and water from a source, to a wash tower to separate a stripped portion of the lean solvent from the clean flue gas to generate a washed clean flue gas and a mixture of the water and the stripped portion of the lean solvent. The method further involves treating at least a portion of the mixture of the water and the stripped portion of the lean solvent via a separation system to separate the water from the stripped portion of the lean solvent.

  11. A modeling and experimental study of flue gas desulfurization in a dense phase tower

    International Nuclear Information System (INIS)

    Chang, Guanqin; Song, Cunyi; Wang, Li

    2011-01-01

    We used a dense phase tower as the reactor in a novel semi-dry flue gas desulfurization process to achieve a high desulfurization efficiency of over 95% when the Ca/S molar ratio reaches 1.3. Pilot-scale experiments were conducted for choosing the parameters of the full-scale reactor. Results show that with an increase in the flue gas flow rate the rate of the pressure drop in the dense phase tower also increases, however, the rate of the temperature drop decreases in the non-load hot gas. We chose a water flow rate of 0.6 kg/min to minimize the approach to adiabatic saturation temperature difference and maximize the desulfurization efficiency. To study the flue gas characteristics under different processing parameters, we simulated the desulfurization process in the reactor. The simulated data matched very well with the experimental data. We also found that with an increase in the Ca/S molar ratio, the differences between the simulation and experimental data tend to decrease; conversely, an increase in the flue gas flow rate increases the difference; this may be associated with the surface reactions caused by collision, coalescence and fragmentation between the dispersed phases.

  12. Investigation of a combined gas-steam system with flue gas recirculation

    Directory of Open Access Journals (Sweden)

    Chmielniak Tadeusz

    2016-06-01

    Full Text Available This article presents changes in the operating parameters of a combined gas-steam cycle with a CO2 capture installation and flue gas recirculation. Parametric equations are solved in a purpose-built mathematical model of the system using the Ebsilon Professional code. Recirculated flue gases from the heat recovery boiler outlet, after being cooled and dried, are fed together with primary air into the mixer and then into the gas turbine compressor. This leads to an increase in carbon dioxide concentration in the flue gases fed into the CO2 capture installation from 7.12 to 15.7%. As a consequence, there is a reduction in the demand for heat in the form of steam extracted from the turbine for the amine solution regeneration in the CO2 capture reactor. In addition, the flue gas recirculation involves a rise in the flue gas temperature (by 18 K at the heat recovery boiler inlet and makes it possible to produce more steam. These changes contribute to an increase in net electricity generation efficiency by 1%. The proposed model and the obtained results of numerical simulations are useful in the analysis of combined gas-steam cycles integrated with carbon dioxide separation from flue gases.

  13. High power electron accelerators for flue gas treatment

    International Nuclear Information System (INIS)

    Zimek, Z.

    2011-01-01

    Flue gas treatment process based on electron beam application for SO 2 and NO x removal was successfully demonstrated in number of laboratories, pilot plants and industrial demonstration facilities. The industrial scale application of an electron beam process for flue gas treatment requires accelerators modules with a beam power 100-500 kW and electron energy range 0.8-1.5 MeV. The most important accelerator parameters for successful flue gas radiation technology implementation are related to accelerator reliability/availability, electrical efficiency and accelerator price. Experience gained in high power accelerators exploitation in flue gas treatment industrial demonstration facility was described and high power accelerator constructions have been reviewed. (author)

  14. New particle formation in the fresh flue-gas plume from a coal-fired power plant: effect of flue-gas cleaning

    Science.gov (United States)

    Mylläri, Fanni; Asmi, Eija; Anttila, Tatu; Saukko, Erkka; Vakkari, Ville; Pirjola, Liisa; Hillamo, Risto; Laurila, Tuomas; Häyrinen, Anna; Rautiainen, Jani; Lihavainen, Heikki; O'Connor, Ewan; Niemelä, Ville; Keskinen, Jorma; Dal Maso, Miikka; Rönkkö, Topi

    2016-06-01

    Atmospheric emissions, including particle number and size distribution, from a 726 MWth coal-fired power plant were studied experimentally from a power plant stack and flue-gas plume dispersing in the atmosphere. Experiments were conducted under two different flue-gas cleaning conditions. The results were utilized in a plume dispersion and dilution model taking into account particle formation precursor (H2SO4 resulted from the oxidation of emitted SO2) and assessment related to nucleation rates. The experiments showed that the primary emissions of particles and SO2 were effectively reduced by flue-gas desulfurization and fabric filters, especially the emissions of particles smaller than 200 nm in diameter. Primary pollutant concentrations reached background levels in 200-300 s. However, the atmospheric measurements indicated that new particles larger than 2.5 nm are formed in the flue-gas plume, even in the very early phases of atmospheric ageing. The effective number emission of nucleated particles were several orders of magnitude higher than the primary particle emission. Modelling studies indicate that regardless of continuing dilution of the flue gas, nucleation precursor (H2SO4 from SO2 oxidation) concentrations remain relatively constant. In addition, results indicate that flue-gas nucleation is more efficient than predicted by atmospheric aerosol modelling. In particular, the observation of the new particle formation with rather low flue-gas SO2 concentrations changes the current understanding of the air quality effects of coal combustion. The results can be used to evaluate optimal ways to achieve better air quality, particularly in polluted areas like India and China.

  15. Mercury sorbent delivery system for flue gas

    Science.gov (United States)

    Klunder,; Edgar, B [Bethel Park, PA

    2009-02-24

    The invention presents a device for the removal of elemental mercury from flue gas streams utilizing a layer of activated carbon particles contained within the filter fabric of a filter bag for use in a flue gas scrubbing system.

  16. High power electron accelerators for flue gas treatment

    Energy Technology Data Exchange (ETDEWEB)

    Zimek, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    2011-07-01

    Flue gas treatment process based on electron beam application for SO{sub 2} and NO{sub x} removal was successfully demonstrated in number of laboratories, pilot plants and industrial demonstration facilities. The industrial scale application of an electron beam process for flue gas treatment requires accelerators modules with a beam power 100-500 kW and electron energy range 0.8-1.5 MeV. The most important accelerator parameters for successful flue gas radiation technology implementation are related to accelerator reliability/availability, electrical efficiency and accelerator price. Experience gained in high power accelerators exploitation in flue gas treatment industrial demonstration facility was described and high power accelerator constructions have been reviewed. (author)

  17. Sorbents for mercury removal from flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Granite, Evan J.; Hargis, Richard A.; Pennline, Henry W.

    1998-01-01

    A review of the various promoters and sorbents examined for the removal of mercury from flue gas is presented. Commercial sorbent processes are described along with the chemistry of the various sorbent-mercury interactions. Novel sorbents for removing mercury from flue gas are suggested. Since activated carbons are expensive, alternate sorbents and/or improved activated carbons are needed. Because of their lower cost, sorbent development work can focus on base metal oxides and halides. Additionally, the long-term sequestration of the mercury on the sorbent needs to be addressed. Contacting methods between the flue gas and the sorbent also merit investigation.

  18. Incineration and flue gas treatment technologies

    International Nuclear Information System (INIS)

    1997-01-01

    The proceedings are presented of an international symposium on Incineration and Flue Gas Treatment Technologies, held at Sheffield University in July 1997. Papers from each of the six sessions cover the behaviour of particles in incinerator clean-up systems, pollution control technologies, the environmental performance of furnaces and incinerators, controlling nitrogen oxide emissions, separation processes during flue gas treatment and regulatory issues relating to these industrial processes. (UK)

  19. Method of treating final products from flue gas desulfurization

    International Nuclear Information System (INIS)

    Bloss, W.; Mohn, U.

    1984-01-01

    A method of treating final products from a flue gas desulfurization. The flue gas desulfurization is carried out by the absorption of sulfur oxide in a spray dryer with a suspension which contains lime, or in a reactor with a dry, fine-grained, absorbent which contains lime. Prior to desulfurization, the fly ash carried along by the flue gas which is to be desulfurized is separated entirely, partially, or not at all from the flue gas, and the final products from the flue gas desulfurization, prior to any further treatment thereof, amount to 1-99% by weight, preferably 1-70% by weight, of fly ash, and 1-99% by weight, preferably 30-99% by weight, of the sum of the desulfurization products, preferably calcium sulfite hemihydrate, and/or calcium sulfite, and/or calcium sulfate dyhydrate, and/or calcium sulfate hemihydrate, and/or calcium sulfate, as well as residue of the absorbent. The reduction of the amount of calcium sulfite is implemented by a dry oxidation with air

  20. Determination of Penetration Depth of 800 keV Electron Beam into Coal Fired Power Plant Flue Gas at in a Electron Beam Machine Flue Gas Treatment System

    International Nuclear Information System (INIS)

    Rany Saptaaji

    2008-01-01

    Penetration depth calculation of 800 keV electron beam into flue gas from coal fired power plan is presented in this paper. Electron Beam for Flue Gas Treatment (EB-FGT) is a dry treatment process using electron beam to simultaneously reduce SO 2 and NO x . Flue gas irradiation produces active radicals and then reaction with SO 2 and NO x produces nitrate acid and sulphate acid. Process vessel is needed in this process as reaction container of flue gas with electron beam. The calculation of electron beam penetration depth into flue gas is used to determine the process vessel dimension. The result of calculation of optimum penetration depth of 800 keV electron beam into flue gas is 188.67 cm. (author)

  1. Flue gas injection into gas hydrate reservoirs for methane recovery and carbon dioxide sequestration

    International Nuclear Information System (INIS)

    Yang, Jinhai; Okwananke, Anthony; Tohidi, Bahman; Chuvilin, Evgeny; Maerle, Kirill; Istomin, Vladimir; Bukhanov, Boris; Cheremisin, Alexey

    2017-01-01

    Highlights: • Flue gas was injected for both methane recovery and carbon dioxide sequestration. • Kinetics of methane recovery and carbon dioxide sequestration was investigated. • Methane-rich gas mixtures can be produced inside methane hydrate stability zones. • Up to 70 mol% of carbon dioxide in the flue gas was sequestered as hydrates. - Abstract: Flue gas injection into methane hydrate-bearing sediments was experimentally investigated to explore the potential both for methane recovery from gas hydrate reservoirs and for direct capture and sequestration of carbon dioxide from flue gas as carbon dioxide hydrate. A simulated flue gas from coal-fired power plants composed of 14.6 mol% carbon dioxide and 85.4 mol% nitrogen was injected into a silica sand pack containing different saturations of methane hydrate. The experiments were conducted at typical gas hydrate reservoir conditions from 273.3 to 284.2 K and from 4.2 to 13.8 MPa. Results of the experiments show that injection of the flue gas leads to significant dissociation of the methane hydrate by shifting the methane hydrate stability zone, resulting in around 50 mol% methane in the vapour phase at the experimental conditions. Further depressurisation of the system to pressures well above the methane hydrate dissociation pressure generated methane-rich gas mixtures with up to 80 mol% methane. Meanwhile, carbon dioxide hydrate and carbon dioxide-mixed hydrates were formed while the methane hydrate was dissociating. Up to 70% of the carbon dioxide in the flue gas was converted into hydrates and retained in the silica sand pack.

  2. Pilot test of flue gas treatment by electron beam

    International Nuclear Information System (INIS)

    Tokunaga, Okihiro

    1995-01-01

    The development of the technology of the desulfurization and denitration for flue gas by using electron beam was started in Japan in 1970s, and since then, the development research for putting it to practical use and the basic research on the subjects which must be resolved for promoting the practical use have been advanced. Based on these results, the verifying test using a pilot scale plant was carried out from 1991 to 1994 for the treatment of coal-burning flue gas, municipal waste-burning flue gas and highway tunnel exhaust gas. The operation of the pilot plant was already finished, and the conceptual design of a practical scale plant based on the results and the assessment of the economical efficiency were performed. As for the coal-burning flue gas treatment by using electron beam, the basic test, the pilot test and the conceptual design of a practical scale plant and the assessment of the economical efficiency are reported. As for the municipal waste-burning flue gas treatment by using electron beam, the basic test and the pilot test are reported. Also the pilot test on the denitration of exhaust gas in highway tunnels in reported. In Poland, the pilot test on the treatment of flue gas in coal-burning thermal power stations is carried out. In Germany, the technical development for cleaning the air contaminated by volatile organic compounds by electron beam irradiation is advanced. (K.I.)

  3. Mollier-h,x diagram for moist flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, H; Hultsch, T; Suder, M

    1984-07-01

    Diagrams and formulae are presented for calculation of enthalpy and moisture content of flue gas from brown coal, heating oil, black coal and brown coal briquet combustion. The enthalpy (in kJ/kg) and moisture (g/kg) diagrams were established by computer graphics for pressure 0.1 MPa. A further diagram is provided for enthalpy and flue gas moisture, varying the combustion air supply according to coal dust and to grate firing. These thermodynamic calculations are regarded as significant for assessing methods of flue gas cooling below the moisture dew point and for waste heat recovery. 3 references.

  4. Overview of flue gas treatment in Brazil

    International Nuclear Information System (INIS)

    Calvo, W.A.P.; Duarte, C.L.; Omi, N.M.; Poli, D.C.R.; Lima, W.

    2011-01-01

    The coal mines in Brazil are primarily located in southern part areas. The total coal reserves are approximately 32.8 billions tons, 89% of which are located in Rio Grande do Sul state. The Brazilian agriculture potentiality is very high, mainly due to the availability of flat land and the existence of industrial capacity to supply the main fertilizers needs. Electron beam flue gas treatment process ensures simultaneous removal of SO 2 and NO X from flue gases by single process, requiring no additional wastewater treatment system and can produce useful nitrogen fertilizer consisting of ammonium sulfate (NH 4 ) 2 SO 4 and ammonium nitrate NH 4 NO 3 as by-products. During the TC Project BRA/8/021 - Pilot Plant for Electron Beam Purification of Flue Gas supported by IAEA (1995-1996), a laboratory facility for electron beam flue gas treatment was set at IPEN. In 1997, an official request from Brazilian Government, Ministry of Science & Technology (MCT) and IPEN was made for the Japan Consulting Institute (JCI) to prepare feasibility studies of air pollution control by electron beam flue gas treatment in three power generation companies. These companies are responsible for the power generation, the transmission and the supply of electricity to Brazil: Jorge Lacerda – Eletrosul Centrais Eletricas do Sul do Brasil S.A., Presidente Medici – Companhia Estadual de Energia Eletrica (CEEE) and Piratininga – AES Eletropaulo Thermal Power Plants. (author)

  5. Overview of flue gas treatment in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Calvo, W. A.P.; Duarte, C. L.; Omi, N. M. [National Nuclear Energy Commission (CNEN), Institute for Nuclear and Energy Research (IPEN), Radiation Technology Center - CTR, Sao Paulo (Brazil); Poli, D. C.R.; Lima, W. [National Nuclear Energy Commission (CNEN), Institute for Nuclear and Energy Research (IPEN), Cyclotron Accelerator Center - CAC, Sao Paulo (Brazil)

    2011-07-01

    The coal mines in Brazil are primarily located in southern part areas. The total coal reserves are approximately 32.8 billions tons, 89% of which are located in Rio Grande do Sul state. The Brazilian agriculture potentiality is very high, mainly due to the availability of flat land and the existence of industrial capacity to supply the main fertilizers needs. Electron beam flue gas treatment process ensures simultaneous removal of SO{sub 2} and NO{sub X} from flue gases by single process, requiring no additional wastewater treatment system and can produce useful nitrogen fertilizer consisting of ammonium sulfate (NH{sub 4}){sub 2}SO{sub 4} and ammonium nitrate NH{sub 4}NO{sub 3} as by-products. During the TC Project BRA/8/021 - Pilot Plant for Electron Beam Purification of Flue Gas supported by IAEA (1995-1996), a laboratory facility for electron beam flue gas treatment was set at IPEN. In 1997, an official request from Brazilian Government, Ministry of Science & Technology (MCT) and IPEN was made for the Japan Consulting Institute (JCI) to prepare feasibility studies of air pollution control by electron beam flue gas treatment in three power generation companies. These companies are responsible for the power generation, the transmission and the supply of electricity to Brazil: Jorge Lacerda – Eletrosul Centrais Eletricas do Sul do Brasil S.A., Presidente Medici – Companhia Estadual de Energia Eletrica (CEEE) and Piratininga – AES Eletropaulo Thermal Power Plants. (author)

  6. Flue Gas Desulphurization Processes

    International Nuclear Information System (INIS)

    Aly, A.I.M.; Halhouli, K.A.; Abu-Ashur, B.M.

    1999-01-01

    Flue gas desulphurization process are discussed. These processes can be grouped into non-regenerable systems and regenerable systems. The non-regenerable systems produce a product which is either disposed of as waste or sold as a by-product e.g. lime/limestone process. While in the regenerable systems, e.g. Wellman-Lord process, the SO 2 is regenerated from the sorbent(sodium sulphite), which is returned to absorb more SO 2 . Also a newer technology for flue gas desulphurization is discussed. The Ispra process uses bromine as oxidant, producing HBr, from which bromine is regenerated by electrolysis. The only by-products of this process are sulphuric acid and hydrogen, which are both valuable products, and no waste products are produced. Suggested modifications on the process are made based on experimental investigations to improve the efficiency of the process and to reduce its costs

  7. Effects of simulated flue gas on components of Scenedesmus raciborskii WZKMT.

    Science.gov (United States)

    Li, Xie-kun; Xu, Jing-liang; Guo, Ying; Zhou, Wei-zheng; Yuan, Zhen-hong

    2015-08-01

    Scenedesmus raciborskii WZKMT cultured with simulated flue gas was investigated. Cellular components, including total sugar, starch, chlorophyll, protein and lipid, were compared between simulated flue gas and 7% (v/v) CO2. Dissolution of SO2 and NO in simulated flue gas led to pH decrease and toxicity to microalgae cells. Furthermore, the death or aging of microalgae cells reduced the buffer capacity and caused decrease of simulated flue gas absorption. With 7% CO2, the highest total sugar and starch content could attain to 66.76% and 53.16%, respectively, which indicated S. raciborskii WZKMT is a desired feedstock candidate for bioethanol production. Microalgae growth and starch accumulation was inhibited, while cells produced more chlorophyll, protein and lipid when simulated flue gas was the carbon source. Fatty acids composition analysis indicated that there was no significant distinction on fatty acids relative content (fatty acid/TFA) between cells aerated using simulated flue gas and 7% CO2. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Improvements in or relating to handling of flue gas

    International Nuclear Information System (INIS)

    Ingham, R.V.

    1986-01-01

    The patent describes improvements in the method for handling flue gas from the burning of fossil fuels. The method relates to cleaning the flue gas, from which the sulphur compounds are removed. The gas in then heated by heat derived from a nuclear source, which may be nuclear waste. The heat treatment gives efficient atmospheric dispersion from the chimney. (U.K.)

  9. Flue gas cleaning chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Gutberlet, H [VEBA Kraftwerke Ruhr AG, Gelsenkirchen (Germany)

    1996-12-01

    The introduction of modern flue gas cleaning technology into fossil-fueled power stations has repeatedly confronted the power station chemists with new and interesting problems over the last 15 - 20 years. Both flue gas desulphurization by lime washing and catalytic removal of nitrogen oxides are based on simple basic chemical reactions. Owing to the use of readily available starting materials, the production of safe, useful end products and, last but not least, the possibility of implementing all this on an industrial scale by means of efficient process engineering, limestone desulphurization and catalytic removal of nitrogen oxides dominate the world market and, little by little, are becoming still more widespread. The origin and thus the quality of fuels and starting materials, the firing method, the mode of operation and engineering peculiarities in each plant interact in a complex manner. Simple cause/effect relationships are frequently incapable of explaining phenomena; thinking in complex interrelationships is needed. (EG)

  10. Pilot plant experience in electron-beam treatment of iron-ore sintering flue gas and its application to coal boiler flue gas cleanup

    International Nuclear Information System (INIS)

    Kawamura, K.

    1984-01-01

    The present development status of the electron-beam flue gas treatment process, which is a dry process capable of removing SOx and NOx simultaneously, is described. The most advanced demonstration of this process was accomplished with a pilot plant in Japan where the maximum gas flow rate of 10,000 Nm 3 /h of an iron-ore sintering machine flue gas was successfully treated. The byproduct produced in this process is collected as a dry powder which is a mixture of ammonia sulfate and ammonium nitrate and is saleable as a fertilizer or a fertilizer component. A preliminary economic projection showed that this process costs less than the lime scrubber which removes SOx but does not remove NOx. Tests using simulated coal combustion gases suggest that this process will be applicable to coal-fired boiler flue gas treatment as well. However, tests on actual coal-fired flue gases are still required for commercial application decisions. A process development unit program consisting of the design, construction and testing of actual coal-fired power station flue gases is underway in the U.S.A. The design and engineering of the test plant is far advanced and the construction phase will be launched in the very near future. (author)

  11. Development of electron beam flue gas treatment technology

    International Nuclear Information System (INIS)

    Tanaka, T.

    1995-01-01

    The electron beam flue gas treatment technology is expected to bring many advantages such as the simultaneous reduction of SO x and NO x emissions, a dry process without waste water, valuable fertilizer byproducts, etc. In order to verify the feasibility and performances of the process, a practical application test is carried out with a pilot plant which treats the actual flue gas from a coal-fired boiler. Results are presented. 4 figs., 2 tabs

  12. First operational tests of an oxycoal hot gas cleaning facility; Erste Betriebstests einer Oxycoal-Heissgasreinigung

    Energy Technology Data Exchange (ETDEWEB)

    Kellermann, A.; Habermehl, M.; Foerster, M.; Kneer, R. [RWTH Aachen University (Germany). Lehrstuhl fuer Waerme- und Stoffuebertragung

    2009-07-01

    An oxyfuel power plant process using a ceramic high temperature membrane for oxygen supply is investigated within the scope of the OXYCOAL-AC project at RWTH Aachen Uni-versity. Implementing the membrane requires a clean gas at a temperature of 850 C. There-fore a hot gas cleaning facility based on porous ceramic candle filters is used, which is state-of-the-art for the gas cleaning of synthesis gas or for flue gas cleaning in pressurised fluid-ised bed furnaces. However, these applications operate at lower temperatures and in a sig-nificantly different atmosphere. Thus, experiences for dust removal at high temperatures in oxyfuel atmoshere are not available. Experiments with a hot gas cleaning facility were con-ducted at the experimental combustion plant of the Institute of Heat and Mass Transfer, us-ing different candle filter materials. The flue gas was provided by a coal fired 100 kW{sub th} oxy-fuel furnace. The operational behaviour of the filtration facility, the adhesion and dedusting properties of the filter cake were investigated. (orig.)

  13. Coal fired flue gas mercury emission controls

    International Nuclear Information System (INIS)

    Wu, Jiang; Pan, Weiguo; Cao, Yan; Pan, Weiping

    2015-01-01

    Mercury (Hg) is one of the most toxic heavy metals, harmful to both the environment and human health. Hg is released into the atmosphere from natural and anthropogenic sources and its emission control has caused much concern. This book introduces readers to Hg pollution from natural and anthropogenic sources and systematically describes coal-fired flue gas mercury emission control in industry, especially from coal-fired power stations. Mercury emission control theory and experimental research are demonstrated, including how elemental mercury is oxidized into oxidized mercury and the effect of flue gas contents on the mercury speciation transformation process. Mercury emission control methods, such as existing APCDs (air pollution control devices) at power stations, sorbent injection, additives in coal combustion and photo-catalytic methods are introduced in detail. Lab-scale, pilot-scale and full-scale experimental studies of sorbent injection conducted by the authors are presented systematically, helping researchers and engineers to understand how this approach reduces the mercury emissions in flue gas and to apply the methods in mercury emission control at coal-fired power stations.

  14. Coal fired flue gas mercury emission controls

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Jiang; Pan, Weiguo [Shanghai Univ. of Electric Power (China); Cao, Yan; Pan, Weiping [Western Kentucky Univ., Bowling Green, KY (United States)

    2015-05-01

    Mercury (Hg) is one of the most toxic heavy metals, harmful to both the environment and human health. Hg is released into the atmosphere from natural and anthropogenic sources and its emission control has caused much concern. This book introduces readers to Hg pollution from natural and anthropogenic sources and systematically describes coal-fired flue gas mercury emission control in industry, especially from coal-fired power stations. Mercury emission control theory and experimental research are demonstrated, including how elemental mercury is oxidized into oxidized mercury and the effect of flue gas contents on the mercury speciation transformation process. Mercury emission control methods, such as existing APCDs (air pollution control devices) at power stations, sorbent injection, additives in coal combustion and photo-catalytic methods are introduced in detail. Lab-scale, pilot-scale and full-scale experimental studies of sorbent injection conducted by the authors are presented systematically, helping researchers and engineers to understand how this approach reduces the mercury emissions in flue gas and to apply the methods in mercury emission control at coal-fired power stations.

  15. Simultaneous flue gas bioremediation and reduction of microalgal biomass production costs

    Energy Technology Data Exchange (ETDEWEB)

    Douskova, I.; Doucha, J.; Livansky, K.; Umysova, D.; Zachleder, V.; Vitova, M. [Academy of Sciences of the Czech Republic, Trebon (Czech Republic). Laboratory of Cell Cycles of Algae; Machat, J. [Masaryk University, Brno (Czech Republic). Research Centre for Environmental Chemistry and Ecotoxicology; Novak, P. [Termizo Inc., Liberec (Czech Republic)

    2009-02-15

    A flue gas originating from a municipal waste incinerator was used as a source of CO{sub 2} for the cultivation of the microalga Chlorella vulgaris, in order to decrease the biomass production costs and to bioremediate CO{sub 2} simultaneously. The utilization of the flue gas containing 10-13% ({nu}/{nu}) CO2 and 8-10% ({nu}/{nu}) O{sub 2} for the photobioreactor agitation and CO{sub 2} supply was proven to be convenient. The growth rate of algal cultures on the flue gas was even higher when compared with the control culture supplied by a mixture of pure CO{sub 2} and air (11% ({nu}/{nu}) CO{sub 2}). Correspondingly, the CO{sub 2} fixation rate was also higher when using the flue gas (4.4 g CO{sub 2} l{sup -1} 24 h{sup -1}) than using the control gas (3.0 g CO{sub 2} l{sup -1} 24 h{sup -1}). The toxicological analysis of the biomass produced using untreated flue gas showed only a slight excess of mercury while all the other compounds (other heavy metals, polycyclic aromatic hydrocarbons, polychlorinated dibenzodioxins and dibenzofurans, and polychlorinated biphenyls) were below the limits required by the European Union foodstuff legislation. Fortunately, extending the flue gas treatment prior to the cultivation unit by a simple granulated activated carbon column led to an efficient absorption of gaseous mercury and to the algal biomass composition compliant with all the foodstuff legislation requirements. (orig.)

  16. Current status of electron beam treatment of flue gas in China

    International Nuclear Information System (INIS)

    Wang Zhiguang

    2006-01-01

    Fossil resource especially coal will remain the main energy resource in China over the next 3 ∼4 decades. Pollution of flue gas from fossil power station is one problem being desiderated to solve since 1990's. Electron beam treatment of flue gas as an advanced technique has been developed and used by some institutes and industries in China. The current status of flue gas treatment using electron beam and the development of electron accelerator in China are reviewed. (author)

  17. Flue gas recirculation to pellets burner

    International Nuclear Information System (INIS)

    Loefgren, B.E.; Blohm, T.

    1999-05-01

    The aim of this project has been to study the influence of flue gas recirculation on the combustion results. Primarily regarding the turbulence, stability and air surplus of the flame, but also the influence on environmental factors (CO and unburnt hydrocarbons). Also studied was the possibility of automatic control of the mixing of recirculating flue gases in the combustion process through the use of a λ-sond and O 2 control Project report from the program: Small scale combustion of biofuels. 9 figs, 8 tabs

  18. Electrochemical flue gas desulfurization: Reactions in a pyrosulfate-based electrolyte

    International Nuclear Information System (INIS)

    Scott, K.; Fannon, T.; Winnick, J.

    1988-01-01

    A new electrolyte has been found suitable for use in an electrochemical membrane cell for flue gas desulfurization (FGD). The electrolyte is primarily K/sub 2/S/sub 2/O/sub 7/ and K/sub 2/SO/sub 4/ with V/sub 2/O/sub 5/ as oxidation enhancer. This electrolyte has a melting point near 300/sup 0/C which is compatible with flue gas exiting the economizer of coal-burning power plants. Standard electrochemical tests have revealed high exchange current densities around 30 mA/cm/sup 2/, in the free electrolyte. Sulfur dioxide is found to be removed from simulated flue gas in a multiple-step process, the first of which is electrochemical reduction of pyrosulfate

  19. The benefits of flue gas recirculation in waste incineration.

    Science.gov (United States)

    Liuzzo, Giuseppe; Verdone, Nicola; Bravi, Marco

    2007-01-01

    Flue gas recirculation in the incinerator combustion chamber is an operative technique that offers substantial benefits in managing waste incineration. The advantages that can be obtained are both economic and environmental and are determined by the low flow rate of fumes actually emitted if compared to the flue gas released when recirculation is not conducted. Simulations of two incineration processes, with and without flue gas recirculation, have been carried out by using a commercial flowsheeting simulator. The results of the simulations demonstrate that, from an economic point of view, the proposed technique permits a greater level of energy recovery (up to +3%) and, at the same time, lower investment costs as far as the equipment and machinery constituting the air pollution control section of the plant are concerned. At equal treatment system efficiencies, the environmental benefits stem from the decrease in the emission of atmospheric pollutants. Throughout the paper reference is made to the EC legislation in the field of environmental protection, thus ensuring the general validity in the EU of the foundations laid and conclusions drawn henceforth. A numerical example concerning mercury emission quantifies the reported considerations and illustrates that flue gas recirculation reduces emission of this pollutant by 50%.

  20. Flue gas condensing with heat pump; Roekgaskondensering med vaermepump

    Energy Technology Data Exchange (ETDEWEB)

    Axby, Fredrik; Pettersson, Camilla [Carl Bro Energikonsult AB, Malmoe (Sweden)

    2004-11-01

    Flue gas condensing is often both a technically and economically efficient method to increase the thermal efficiency in a plant using fuels with high moisture and/or high hydrogen content. The temperature of the return water in district heating systems in Sweden is normally 50 deg C, which gives quite high efficiency for a flue gas condenser. The flue gas after the flue gas condenser still contains energy that to some extent can be recovered by a combustion air humidifier or a heat pump. The object of this project is to technically and economically analyse flue gas condensing with heat pump. The aim is that plant owners get basic data to evaluate if a coupling between a flue gas condenser and a heat pump could be of interest for their plant. With a heat pump the district heating water can be 'sub cooled' to increase the heat recover in the flue gas condenser and thereby increase the total efficiency. The project is set up as a case study of three different plants that represent different types of technologies and sizes; Aabyverket in Oerebro, Amagerforbraending in Copenhagen and Staffanstorp district heating central. In this report a system with a partial flow through the condenser of the heat pump is studied. For each plant one case with the smallest heat pump and a total optimization regarding total efficiency and cost for investment has been calculated. In addition to the optimizations sensitivity analyzes has been done of the following parameters: Moisture in fuel; Type of heat pump; Temperature of the return water in the district heating system; and, Size of plant. The calculations shows that the total efficiency increases with about 6 % by the installation of the heat pump at a temperature of the return water in the district heating system of 50 deg C at Aabyverket. The cost for production of heat is just below 210 kr/MWh and the straight time for pay-off is 5,4 years at 250 kr/MWh in heat credit and at 300 kr/MWh in basic price for electricity. The

  1. Theoretical prediction the removal of mercury from flue gas by MOFs

    KAUST Repository

    Liu, Yang; Li, Hailong; Liu, Jing

    2016-01-01

    Removal of mercury from flue gas has been considered as one of the hot topics in both the scientific and industrial world. Adsorption of elemental mercury (Hg) and oxidized mercury species (HgCl, HgO, and HgS) on a novel metal organic framework (MOF) material, named Mg/DOBDC, with unsaturated metal centers was investigated using density functional theory (DFT) calculations. The results show that Hg stably physi-sorbed on the unsaturated metal center (magnesium ion) of Mg/DOBDC with a binding energy (BE) of −27.5 kJ/mol. A direct interaction between Hg and magnesium ion was revealed by the partial density of state (PDOS) analysis. HgCl multi-interacts with two neighboring magnesium ions simultaneously by its Cl endings and thus resulted in strong adsorption strength (−89.0 kJ/mol). The adsorption energies of HgO and HgS on the Mg/DOBDC were as high as −117.0 kJ/mol and −169.7 kJ/mol, respectively, indicating a strong chemisorption. Theoretical calculations in this study reveal that Mg/DOBDC has the potential to serve as an efficient material for removal of mercury from flue gas.

  2. Theoretical prediction the removal of mercury from flue gas by MOFs

    KAUST Repository

    Liu, Yang

    2016-07-19

    Removal of mercury from flue gas has been considered as one of the hot topics in both the scientific and industrial world. Adsorption of elemental mercury (Hg) and oxidized mercury species (HgCl, HgO, and HgS) on a novel metal organic framework (MOF) material, named Mg/DOBDC, with unsaturated metal centers was investigated using density functional theory (DFT) calculations. The results show that Hg stably physi-sorbed on the unsaturated metal center (magnesium ion) of Mg/DOBDC with a binding energy (BE) of −27.5 kJ/mol. A direct interaction between Hg and magnesium ion was revealed by the partial density of state (PDOS) analysis. HgCl multi-interacts with two neighboring magnesium ions simultaneously by its Cl endings and thus resulted in strong adsorption strength (−89.0 kJ/mol). The adsorption energies of HgO and HgS on the Mg/DOBDC were as high as −117.0 kJ/mol and −169.7 kJ/mol, respectively, indicating a strong chemisorption. Theoretical calculations in this study reveal that Mg/DOBDC has the potential to serve as an efficient material for removal of mercury from flue gas.

  3. Dosimetry for combustion flue gas treatment with electron beam

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, K.; Bułka, S.; Sun, Y. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    2011-07-01

    The electron beam treatment of flue gas is one of the new technologies. There are several reasons for carrying out dosimetry at various phases of the project as understanding the process and optimizing the equipment, for process control and for troubleshooting in case of malfunction etc. The main challenge in measuring dose for flue gas applications is that the medium being irradiated is gaseous. Two general approaches for dose measurements are: adding/placing some dosimeters in the reaction vessel (gas) and using the components of the gas itself as a dosimeter. Various techniques and methods have been tried which are discussed in this paper. (author)

  4. Flue gas condensation in straw fired CHP plants; Roeggaskondensation i halmfyrede kraftvarmeanlaeg

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-06-15

    The high price of straw and a general demand for increased use of straw in power and heat production are expected to result in an increased need for efficient fuel utilization. The use of flue gas condensation in straw fired CHP plants can contribute to a higher exploitation of energy, and at the same time open of the possibility of utilization of wet (cheaper) fuels without energy loss. Furthermore flue gas condensation can contribute to the flue gas cleaning process through removal of HCl and SO{sub 2} as well as in particle cleaning in wet cleaning processes. With starting point in a straw fired CHP plant the technical and economic consequences of installation of a flue gas condensation system are investigated. Fuel exploitation and power/heat production distribution is included in the investigation. (BA)

  5. Fundamental mechanisms in flue-gas conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Dahlin, R.S.; Vann Bush, P.; Snyder, T.R.

    1992-01-09

    The overall goal of this research project is to formulate a mathematical model of flue gas conditioning. This model will be based on an understanding of why ash properties, such as cohesivity and resistivity, are changed by conditioning. Such a model could serve as a component of the performance models of particulate control devices where flue gas conditioning is used. There are two specific objectives of this research project, which divide the planned research into two main parts. One part of the project is designed to determine how ash particles are modified by interactions with sorbent injection processes and to describe the mechanisms by which these interactions affect fine particle collection. The objective of the other part of the project is to identify the mechanisms by which conditioning agents, including chemically active compounds, modify the key properties of fine fly ash particles.

  6. Thermodynamic properties calculation of the flue gas based on its composition estimation for coal-fired power plants

    International Nuclear Information System (INIS)

    Xu, Liang; Yuan, Jingqi

    2015-01-01

    Thermodynamic properties of the working fluid and the flue gas play an important role in the thermodynamic calculation for the boiler design and the operational optimization in power plants. In this study, a generic approach to online calculate the thermodynamic properties of the flue gas is proposed based on its composition estimation. It covers the full operation scope of the flue gas, including the two-phase state when the temperature becomes lower than the dew point. The composition of the flue gas is online estimated based on the routinely offline assays of the coal samples and the online measured oxygen mole fraction in the flue gas. The relative error of the proposed approach is found less than 1% when the standard data set of the dry and humid air and the typical flue gas is used for validation. Also, the sensitivity analysis of the individual component and the influence of the measurement error of the oxygen mole fraction on the thermodynamic properties of the flue gas are presented. - Highlights: • Flue gas thermodynamic properties in coal-fired power plants are online calculated. • Flue gas composition is online estimated using the measured oxygen mole fraction. • The proposed approach covers full operation scope, including two-phase flue gas. • Component sensitivity to the thermodynamic properties of flue gas is presented.

  7. Membranes for Flue Gas Treatment - Transport behavior of water and gas in hydrophilic polymer membranes

    NARCIS (Netherlands)

    Potreck, Jens

    2009-01-01

    Fossil fuel fired power plants produce electricity and in addition to that large volume flows of flue gas, which mainly contain N2, O2, and CO2, but also large quantities of water vapor. To prevent condensation of the water vapor present in this flue gas stream, water needs to be removed before

  8. Assessment of corrosion in the flue gas cleaning system using on-line monitoring

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Vendelbo Nielsen, Lars; Berggreen Petersen, Michael

    2015-01-01

    Amager unit 1 is a 350 MW multifuel suspension-fired plant commissioned in 2009 to fire biomass (straw and wood pellets). Increasing corrosion problems in the flue gas cleaning system were observed in the gas-gas preheater (GAFO), the booster fan and flue gas ducts. Chlorine containing corrosion ...

  9. Feature of flue gas treatment by electron-beam irradiation and details of its development

    International Nuclear Information System (INIS)

    Tokunaga, Okihiro; Suzuki, Nobutake.

    1986-01-01

    The method of flue gas treatment with an electron beam, developed jointly by Japan Atomic Energy Research Institute and Ebara Corporation, is promising as a simple, dry process, not using a catalyst, of the desulfurization and denitration. In the procedure, flue gas is irradiated with an electron beam in the presence of ammonia, so that sulfurous acid gas and nitrogen oxide are converted to ammonium sulfate and ammonium nitrate particles, which are then removed. The method is already demonstrated in the flue gas treatment of an iron ore sintering furnace as pilot test. And further, the pilot tests in coal combustion flue gas treatment are proceeding in the United States and West Germany. For the flue gas treatment method using an electron beam, the mechanisms of desulfurization and denitration, the course taken in its development and the present state of development are described, and also the future outlook and problems. (Mori, K.)

  10. An analysis of main factors in electron beam flue gas purification

    International Nuclear Information System (INIS)

    Zhang Ming; Xu Guang

    2003-01-01

    Electron beam flue gas purification method is developing very quickly in recent years. Based on the experiment setting for electron beam flue gas purification in Institute of Nuclear Energy and Technology, Tsinghua University, how the technique factors affect the ratio of desulphurization and denitrogenation are described. Radiation dose (D), temperature (T), humidity (H), pour ammonia quantity (α) and initial concentration of SO 2 (C SO 2 ) and NO x (C NO x ) are main factors influencing flue gas purification. Using the methods of correlation analysis and regression analysis, the primary effect factors are found out and the regression equations are set to optimize the system process, predigest the system structure and to forecast the experimental results. (authors)

  11. Stress analysis of the O-element pipe during the process of flue gases purification

    Directory of Open Access Journals (Sweden)

    Nekvasil R.

    2008-11-01

    Full Text Available Equipment for flue gases purification from undesired substances is used throughout power and other types of industry. This paper deals with damaging of the O-element pipe designed to remove sulphur from the flue gases, i.e. damaging of the pipe during flue gases purification. This purification is conducted by spraying the water into the O-shaped pipe where the flue gases flow. Thus the sulphur binds itself onto the water and gets removed from the flue gas. Injection of cold water into hot flue gases, however, causes high stress on the inside of the pipe, which can gradually damage the O-element pipe. In this paper initial injection of water into hot pipe all the way to stabilization of temperature fields will be analyzed and the most dangerous places which shall be considered for fatigue will be determined.

  12. Potential flue gas impurities in carbon dioxide streams separated from coal-fired power plants.

    Science.gov (United States)

    Lee, Joo-Youp; Keener, Tim C; Yang, Y Jeffery

    2009-06-01

    For geological sequestration of carbon dioxide (CO2) separated from pulverized coal combustion flue gas, it is necessary to adequately evaluate the potential impacts of flue gas impurities on groundwater aquifers in the case of the CO2 leakage from its storage sites. This study estimated the flue gas impurities to be included in the CO2 stream separated from a CO2 control unit for a different combination of air pollution control devices and different flue gas compositions. Specifically, the levels of acid gases and mercury vapor were estimated for the monoethanolamine (MEA)-based absorption process on the basis of published performance parameters of existing systems. Among the flue gas constituents considered, sulfur dioxide (SO2) is known to have the most adverse impact on MEA absorption. When a flue gas contains 3000 parts per million by volume (ppmv) SO2 and a wet flue gas desulfurization system achieves its 95% removal, approximately 2400 parts per million by weight (ppmw) SO2 could be included in the separated CO2 stream. In addition, the estimated concentration level was reduced to as low as 135 ppmw for the SO2 of less than 10 ppmv in the flue gas entering the MEA unit. Furthermore, heat-stable salt formation could further reduce the SO2 concentration below 40 ppmw in the separated CO2 stream. In this study, it is realized that the formation rates of heat-stable salts in MEA solution are not readily available in the literature and are critical to estimating the levels and compositions of flue gas impurities in sequestered CO2 streams. In addition to SO2, mercury, and other impurities in separated CO2 streams could vary depending on pollutant removal at the power plants and impose potential impacts on groundwater. Such a variation and related process control in the upstream management of carbon separation have implications for groundwater protection at carbon sequestration sites and warrant necessary considerations in overall sequestration planning

  13. Flue gas adsorption by single-wall carbon nanotubes: A Monte Carlo study.

    Science.gov (United States)

    Romero-Hermida, M I; Romero-Enrique, J M; Morales-Flórez, V; Esquivias, L

    2016-08-21

    Adsorption of flue gases by single-wall carbon nanotubes (SWCNT) has been studied by means of Monte Carlo simulations. The flue gas is modeled as a ternary mixture of N2, CO2, and O2, emulating realistic compositions of the emissions from power plants. The adsorbed flue gas is in equilibrium with a bulk gas characterized by temperature T, pressure p, and mixture composition. We have considered different SWCNTs with different chiralities and diameters in a range between 7 and 20 Å. Our results show that the CO2 adsorption properties depend mainly on the bulk flue gas thermodynamic conditions and the SWCNT diameter. Narrow SWCNTs with diameter around 7 Å show high CO2 adsorption capacity and selectivity, but they decrease abruptly as the SWCNT diameter is increased. For wide SWCNT, CO2 adsorption capacity and selectivity, much smaller in value than for the narrow case, decrease mildly with the SWCNT diameter. In the intermediate range of SWCNT diameters, the CO2 adsorption properties may show a peculiar behavior, which depend strongly on the bulk flue gas conditions. Thus, for high bulk CO2 concentrations and low temperatures, the CO2 adsorption capacity remains high in a wide range of SWCNT diameters, although the corresponding selectivity is moderate. We correlate these findings with the microscopic structure of the adsorbed gas inside the SWCNTs.

  14. Flue gas adsorption by single-wall carbon nanotubes: A Monte Carlo study

    International Nuclear Information System (INIS)

    Romero-Hermida, M. I.; Romero-Enrique, J. M.; Morales-Flórez, V.; Esquivias, L.

    2016-01-01

    Adsorption of flue gases by single-wall carbon nanotubes (SWCNT) has been studied by means of Monte Carlo simulations. The flue gas is modeled as a ternary mixture of N 2 , CO 2 , and O 2 , emulating realistic compositions of the emissions from power plants. The adsorbed flue gas is in equilibrium with a bulk gas characterized by temperature T, pressure p, and mixture composition. We have considered different SWCNTs with different chiralities and diameters in a range between 7 and 20 Å. Our results show that the CO 2 adsorption properties depend mainly on the bulk flue gas thermodynamic conditions and the SWCNT diameter. Narrow SWCNTs with diameter around 7 Å show high CO 2 adsorption capacity and selectivity, but they decrease abruptly as the SWCNT diameter is increased. For wide SWCNT, CO 2 adsorption capacity and selectivity, much smaller in value than for the narrow case, decrease mildly with the SWCNT diameter. In the intermediate range of SWCNT diameters, the CO 2 adsorption properties may show a peculiar behavior, which depend strongly on the bulk flue gas conditions. Thus, for high bulk CO 2 concentrations and low temperatures, the CO 2 adsorption capacity remains high in a wide range of SWCNT diameters, although the corresponding selectivity is moderate. We correlate these findings with the microscopic structure of the adsorbed gas inside the SWCNTs.

  15. Advanced CFD modelling of air and recycled flue gas staging in a waste wood-fired grate boiler for higher combustion efficiency and greater environmental benefits.

    Science.gov (United States)

    Rajh, Boštjan; Yin, Chungen; Samec, Niko; Hriberšek, Matjaž; Kokalj, Filip; Zadravec, Matej

    2018-07-15

    Grate-fired boilers are commonly used to burn biomass/wastes for heat and power production. In spite of the recent breakthrough in integration of advanced secondary air systems in grate boilers, grate-firing technology needs to be advanced for higher efficiency and lower emissions. In this paper, innovative staging of combustion air and recycled flue gas in a 13 MW th waste wood-fired grate boiler is comprehensively studied based on a numerical model that has been previously validated. In particular, the effects of the jet momentum, position and orientation of the combustion air and recycled flue gas streams on in-furnace mixing, combustion and pollutant emissions from the boiler are examined. It is found that the optimized air and recycled flue gas jets remarkably enhance mixing and heat transfer, result in a more uniform temperature and velocity distribution, extend the residence time of the combustibles in the hot zone and improve burnout in the boiler. Optimizing the air and recycled flue gas jet configuration can reduce carbon monoxide emission from the boiler by up to 86%, from the current 41.0 ppm to 5.7 ppm. The findings of this study can serve as useful guidelines for novel design and optimization of the combustion air supply and flue gas recycling for grate boilers of this type. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Solubility of flue gas components in NaOH based scrubber solutions

    Energy Technology Data Exchange (ETDEWEB)

    Sandelin, K; Backman, R

    1997-11-01

    The work reported here is a thermodynamic study on the solubility of flue gas components in aqueous solutions containing sodium salts. The result of the work is an equilibrium model. The model presented here includes sodium hydroxide and sodium salts that makes it possible to study simultaneous absorption of flue gas components in alkaline scrubber solutions. The model is applied on the absorption of a flue gas into a NaOH scrubber solution. The calculations show that it is possible to simultaneously absorb sulfur dioxide, sulfuric acid, and ammonia without carbon dioxide co-absorption. The calculations also show that gaseous NO and N{sub 2}O cannot be scrubbed unless they are oxidized to nitrate or reduced to ammonia. (author) SIHTI 2 Research Programme. 59 refs.

  17. Incineration and flue gas cleaning in China - a Review

    International Nuclear Information System (INIS)

    Buekens, Alfons; Yan, Mi; Jiang, Xuguan; Li, Xiaodong; Lu, Shengyong; Chi, Yong; Yan, Jianhua; Cen, Kefa

    2010-01-01

    Waste incineration is rapidly developing in China. Different technologies are proposed for Municipal Solid Waste (MSW), Hazardous Waste (HW), and Medical Waste (MW). The required technologies are either imported, or developed locally. Some data are cited to illustrate these rapid developments. Incinerator flue gas arises at rather limited scale (10,000-100,000 Nm 3 /h), compared to power generation, yet the number of pollutants to be counted with is huge: dust and grit, acid gases, NO x , selected heavy metals, aerosols and nanoparticles, Polycyclic Aromatic Hydrocarbons, and dioxins. Major options in flue gas cleaning can be derived from Best Available Technologies (BAT), as were developed in the European Union. Hence, E.U. practice is analyzed in some detail, by considering the present situation in selected E.U. countries (Germany, Sweden, the Netherlands, Denmark, Belgium). A comparison is made with China. Also, the situation in Japan is examined. Based on this wide experience, a number of technical suggestions regarding incineration, flue gas cleaning, and emission control are formulated. Also, the possibility of co incineration is considered. Starting from the particular experience of Zhejiang University (as a designer of Fluid Bed and Rotary Kiln plant, with large experience in Fluid Bed processes, coal firing, gasification and pyrolysis, and actively monitoring thermal units throughout China) some specific Case Studies are examined, e.g., a fluidized bed incinerator and its gas cleaning system (MSWI and HWI from ITPE). Some attention is paid to the potential threats in China from uncontrolled combustion sources. As a conclusion, some recommendations are formulated regarding flue gas cleaning in Developing Nations at large and in China in particular. (author)

  18. Calculating the flue gas dew point for raw brown coal fired steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Schinkel, W.

    1977-01-01

    The paper analyzes parameters influencing the sulfuric acid dew point in flue gas of steam generators. Sulfur content and alkaline earths content in the fuel air ratio during combustion, fly ash content in the flue gas (which absorbs sulfur dioxide and sulfur trioxide) and combustion conditions in steam generators are relevant parameters in the combustion process. A thermodynamic and reaction kinetic calculation of the sulfuric acid dew point is, however, not yet possible. A statistical evaluation of dew point measurements in steam generators is, therefore, employed. Various diagrams show results of dew point measurements carried out at generators with steam capacities ranging from 40 to 660 t/h, which demonstrate relations of these parameters to flue gas dew points, in particular the relative sulfur content (sulfur content in the raw brown coal compared to coal ash content and alkaline earths content). A function is derived for the conversion of fuel sulfur to sulfur trioxide. A diagram presents the relation of the flue gas dew point to partial pressures of sulfuric acid and steam. Direct calculation of the flue gas dew point was achieved by the proposed method. It is applied in steam generator design. (17 refs.)

  19. Flue gas adsorption by single-wall carbon nanotubes: A Monte Carlo study

    Energy Technology Data Exchange (ETDEWEB)

    Romero-Hermida, M. I. [Departamento de Química Física, Facultad de Ciencias, Universidad de Cádiz, Campus Río San Pedro s/n, 11510 Puerto Real (Spain); Departamento de Física Condensada, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla (Spain); Romero-Enrique, J. M. [Departamento de Física Atómica, Molecular y Nuclear, Área de Física Teórica, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla (Spain); Morales-Flórez, V.; Esquivias, L. [Departamento de Física Condensada, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla (Spain); Instituto de Ciencia de Materiales de Sevilla (CSIC/US), Av. Américo Vespucio 49, 41092 Sevilla (Spain)

    2016-08-21

    Adsorption of flue gases by single-wall carbon nanotubes (SWCNT) has been studied by means of Monte Carlo simulations. The flue gas is modeled as a ternary mixture of N{sub 2}, CO{sub 2}, and O{sub 2}, emulating realistic compositions of the emissions from power plants. The adsorbed flue gas is in equilibrium with a bulk gas characterized by temperature T, pressure p, and mixture composition. We have considered different SWCNTs with different chiralities and diameters in a range between 7 and 20 Å. Our results show that the CO{sub 2} adsorption properties depend mainly on the bulk flue gas thermodynamic conditions and the SWCNT diameter. Narrow SWCNTs with diameter around 7 Å show high CO{sub 2} adsorption capacity and selectivity, but they decrease abruptly as the SWCNT diameter is increased. For wide SWCNT, CO{sub 2} adsorption capacity and selectivity, much smaller in value than for the narrow case, decrease mildly with the SWCNT diameter. In the intermediate range of SWCNT diameters, the CO{sub 2} adsorption properties may show a peculiar behavior, which depend strongly on the bulk flue gas conditions. Thus, for high bulk CO{sub 2} concentrations and low temperatures, the CO{sub 2} adsorption capacity remains high in a wide range of SWCNT diameters, although the corresponding selectivity is moderate. We correlate these findings with the microscopic structure of the adsorbed gas inside the SWCNTs.

  20. Flue gas desulfurization/denitrification using metal-chelate additives

    Science.gov (United States)

    Harkness, J.B.L.; Doctor, R.D.; Wingender, R.J.

    1985-08-05

    A method of simultaneously removing SO/sub 2/ and NO from oxygen-containing flue gases resulting from the combustion of carbonaceous material by contacting the flue gas with an aqueous scrubber solution containing an aqueous sulfur dioxide sorbent and an active metal chelating agent which promotes a reaction between dissolved SO/sub 2/ and dissolved NO to form hydroxylamine N-sulfonates. The hydroxylamine sulfonates are then separated from the scrubber solution which is recycled. 3 figs.

  1. Techno-economic analysis and optimization of the heat recovery of utility boiler flue gas

    International Nuclear Information System (INIS)

    Xu, Gang; Huang, Shengwei; Yang, Yongping; Wu, Ying; Zhang, Kai; Xu, Cheng

    2013-01-01

    Highlights: • Four typical flue gas heat recovery schemes are quantitatively analyzed. • The analysis considers thermodynamic, heat transfer and hydrodynamics factors. • Techno-economic analysis and optimization design are carried out. • High-stage steam substitute scheme obtains better energy-saving effect. • Large heat transfer area and high flue gas resistances weaken overall performance. - Abstract: Coal-fired power plants in China consume nearly half of available coals, and the resulting CO 2 emissions cover over 40% of total national emissions. Therefore, reducing the energy expenditure of coal-fired power plants is of great significance to China’s energy security and greenhouse gas reduction programs. For coal-fired power plants, the temperature of a boiler’s exhaust gas reaches 120–150 °C or even higher. The thermal energy of boiler’s exhaust accounts for approximately 3–8% of the total energy of fuel input. Given these factors, we conducted a techno-economic analysis and optimization design of the heat recovery system using boiler exhaust gas. This research is conformed to the principles of thermodynamic, heat transfer, and hydrodynamics. Based on the data from an existing 1000 MW typical power generation unit in China, four typical flue gas heat recovery schemes are quantitatively analyzed from the thermodynamics perspective. The impacts of flue gas heat recovery on net work output and standard coal consumption rate of various schemes are performed. Furthermore, the transfer area of heat recovery exchanger and the draft fan work increment due to the flue gas pressure drop are analyzed. Finally, a techno-economic analysis of the heat recovery schemes is conducted, and some recommendations on optimization design parameters are proposed, with full consideration of various factors such as the decrease on fuel cost due to energy conservation as well as the investment cost of heat recovery retrofitting. The results revealed that, high

  2. Method for removing heavy metal and nitrogen oxides from flue gas, device for removing heavy metal and nitrogen oxides from flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Hann-Sheng; Livengood, Charles David

    1997-12-01

    A method for the simultaneous removal of oxides and heavy metals from a fluid is provided comprising combining the fluid with compounds containing alkali and sulfur to create a mixture; spray drying the mixture to create a vapor phase and a solid phase; and isolating the vapor phase from the solid phase. A device is also provided comprising a means for spray-drying flue gas with alkali-sulfide containing liquor at a temperature sufficient to cause the flue gas to react with the compounds so as to create a gaseous fraction and a solid fraction and a means for directing the gaseous fraction to a fabric filter.

  3. Pilot-scale tests for EB flue gas treatment process in Japan

    International Nuclear Information System (INIS)

    Sato, S.; Tokunaga, O.; Namba, H.

    1994-01-01

    A review of electron beam applications for flue gas treatment in Japan has been done. Several pilot plants are being performed for commercial use of electron beams process for cleaning of flue gas from low-sulfur coal burning boiler, a municipal waste incinerator and for removal of NO x from a ventilation exhaust of a highway tunnel. Outlines of three pilot-scale tests are introduced. 9 refs, 4 figs

  4. Current Techniques of Growing Algae Using Flue Gas from Exhaust Gas Industry: a Review.

    Science.gov (United States)

    Huang, Guanhua; Chen, Feng; Kuang, Yali; He, Huan; Qin, An

    2016-03-01

    The soaring increase of flue gas emission had caused global warming, environmental pollution as well as climate change. Widespread concern on reduction of flue gas released from industrial plants had considered the microalgae as excellent biological materials for recycling the carbon dioxide directly emitted from exhaust industries. Microalgae also have the potential to be the valuable feedback for renewable energy production due to their high growth rate and abilities to sequester inorganic carbon through photosynthetic process. In this review article, we will illustrate important relative mechanisms in the metabolic processes of biofixation by microalgae and their recent experimental researches and advances of sequestration of carbon dioxide by microalgae on actual industrial and stimulate flue gases, novel photobioreactor cultivation systems as well as the perspectives and limitations of microalgal cultivation in further development.

  5. Utilization of carbon dioxide in industrial flue gases for the cultivation of microalga Chlorella sp.

    Science.gov (United States)

    Kao, Chien-Ya; Chen, Tsai-Yu; Chang, Yu-Bin; Chiu, Tzai-Wen; Lin, Hsiun-Yu; Chen, Chun-Da; Chang, Jo-Shu; Lin, Chih-Sheng

    2014-08-01

    The biomass and lipid productivity of Chlorella sp. MTF-15 cultivated using aeration with flue gases from a coke oven, hot stove or power plant in a steel plant of the China Steel Corporation in Taiwan were investigated. Using the flue gas from the coke oven, hot stove or power plant for cultivation, the microalgal strain obtained a maximum specific growth rate and lipid production of (0.827 d(-1), 0.688 g L(-1)), (0.762 d(-1), 0.961 g L(-1)), and (0.728 d(-1), 0.792 g L(-1)), respectively. This study demonstrated that Chlorella sp. MTF-15 could efficiently utilize the CO₂, NOX and SO₂ present in the different flue gases. The results also showed that the growth potential, lipid production and fatty acid composition of the microalgal strain were dependent on the composition of the flue gas and on the operating strategy deployed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Conditions for lowering the flue gas temperature; Foerutsaettning foer saenkning av roekgastemperatur

    Energy Technology Data Exchange (ETDEWEB)

    Nordling, Magnus

    2012-02-15

    In heat and power production, the efficiency of the power plant increases the larger share of heat from the flue gas that is converted to power. However, this also implies that the temperature of the heat exchanging surfaces is lowered. If the temperature is lowered to a temperature below the dew point of the flue gas, this would result in condensation of the gas, which in turn elevates the risk of serious corrosion attack on the surfaces where condensation occurs. Thus, it is important to determine the dew point temperature. One way of determining the dew point temperature is to use data on composition of the fuel together with operation parameters of the plant, thus calculating the dew point temperature. However, this calculation of the dew point is not so reliable, especially if hygroscopic salts are present. Therefore, for safety reasons, the temperature of the flue gas is kept well above the dew point temperature. This results in lowered over-all efficiency of the plant. It could also be expected that for a certain plant, some construction materials under certain operation conditions would have corrosion characteristics that may allow condensation on the surface without severe and unpredictable corrosion attack. However, by only using operation parameters and fuel composition, it is even harder to predict the composition of the condensate at different operation temperatures than to calculate the dew point temperature. If the dew point temperature was known with a greater certainty, the temperature of the flue gas could be kept lower, just above the estimated value of the dew point, without any increased risk for condensation. If, in addition, also the resulting composition of the condensate at different temperatures below the dew point is known, it can be predicted if the construction materials of the flue gas channel were compatible with the formed condensate. If they are compatible, the flue gas temperature can be further lowered from the dew point

  7. Carbon dioxide absorber and regeneration assemblies useful for power plant flue gas

    Science.gov (United States)

    Vimalchand, Pannalal; Liu, Guohai; Peng, Wan Wang

    2012-11-06

    Disclosed are apparatus and method to treat large amounts of flue gas from a pulverized coal combustion power plant. The flue gas is contacted with solid sorbents to selectively absorb CO.sub.2, which is then released as a nearly pure CO.sub.2 gas stream upon regeneration at higher temperature. The method is capable of handling the necessary sorbent circulation rates of tens of millions of lbs/hr to separate CO.sub.2 from a power plant's flue gas stream. Because pressurizing large amounts of flue gas is cost prohibitive, the method of this invention minimizes the overall pressure drop in the absorption section to less than 25 inches of water column. The internal circulation of sorbent within the absorber assembly in the proposed method not only minimizes temperature increases in the absorber to less than 25.degree. F., but also increases the CO.sub.2 concentration in the sorbent to near saturation levels. Saturating the sorbent with CO.sub.2 in the absorber section minimizes the heat energy needed for sorbent regeneration. The commercial embodiments of the proposed method can be optimized for sorbents with slower or faster absorption kinetics, low or high heat release rates, low or high saturation capacities and slower or faster regeneration kinetics.

  8. Fluid dynamic computations of the flue-gas channel in an evaporative gas turbine

    Energy Technology Data Exchange (ETDEWEB)

    Engdar, Ulf

    1999-12-01

    A new pilot power plant, based on an advanced thermodynamic cycle, called Evaporative Gas Turbine (EvGT), has been erected at the department for Heat- and Power Engineering, Lund University. The pilot plant is a part of the Evaporative Gas Turbine project, a cooperation between universities and industry in Sweden. The fluid dynamics layout of the plant is not optimized and hence no pressure drop reduction modifications have been made on the plant. A pressure drop will decrease the efficiency of the plant. Temperature measurements have shown that there maybe is a temperature stratification of the flow on the flue-gas side downstream the recuperator. A temperature stratification will influence the measurements and heat exchangers. The objective of this thesis is to investigate pressure drops and temperature stratification in the flue-gas channel between the recuperator and the economizer at the present pilot plant. Further, suggest modifications that can reduce pressure drops and/or a temperature stratification of the flow. The way of dealing with these problems was to utilize computational fluid dynamics (CFD), which makes it possible to compute the flue-gas channel in detail. The CFD-computations were conducted with a commercial computer program, called Star-CD. The pressure drop was calculated as the sum of the static- and the dynamic- pressure drop. No information about the shape of the temperature stratification was available to investigate whether a stratification will sustain or vanish. Therefore, two different temperature profiles was applied at the outlet of the recuperator. To compare modifications with the present plant, concerning the temperature stratification, a temperature rms-value was utilized as a measure of the deviation from a flow with constant temperature over a cross-section. The computations show that the pressure drop in the flue-gas channel is small compared to the pressure drop over the recuperator. Therefore, no pressure drop reducing

  9. Heat recovery from flue gas of coal fired installations with reduced pollutant emission - the Zittau process

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, H; Strauss, R; Hofmann, K -D; Suder, M; Hultsch, T; Wetzel, W; Gabrysch, H; Jung, J [Technische Hochschule, Zittau (German Democratic Republic)

    1989-01-01

    Explains the Zittau technology of combined flue gas heat recovery and flue gas desulfurization in small brown coal fired power plants. Steam generators to be equipped with this technology have 6.5 or 10 t/h steam capacity and are intended for combustion of low-grade brown coal (8.2 MJ/kg). An industrial 6.5 t/h prototype steam generator is in operation and it achieves 95% SO{sub 2} removal from flue gas with 5600 to 7800 mg SO{sub 2} per m{sup 3} of dry flue gas. The Zittau technology is available in 3 variants: with maximum waste heat recovery, with partial waste heat recovery or without waste heat recovery and only wet flue gas scrubbing. Two flowsheets of flue gas and suspension circulation are provided. The first variant recovers 25.7% of nominal heat capacity (1.1 thermal MW from a 4.2 MW steam generator with 6.5 t/h steam capacity), which amounts to economizing 2,400 t/a brown coal equivalent over 4,000 annual operating hours. The second variant recovers 6.5% of waste heat, requiring less investment by installing smaller heat exchangers than used in the first variant. All three variants have contact spray separators, suction units and suspension preparation equipment. Flue gas suspension scrubbing is carried out with fly ash produced by the steam generator. This ash is capable of absorbing 50 to 70% of flue gas SO{sub 2}. Supply of additional ash from other plants achieve a further 25% SO{sub 2} removal; a higher desulfurization degree is obtained by adding limestone to suspensions. 5 refs.

  10. Production of activated char from Illinois coal for flue gas cleanup

    Science.gov (United States)

    Lizzio, A.A.; DeBarr, J.A.; Kruse, C.W.

    1997-01-01

    Activated chars were produced from Illinois coal and tested in several flue gas cleanup applications. High-activity chars that showed excellent potential for both SO2 and NOx removal were prepared from an Illinois No. 2 bituminous coal. The SO2 (120 ??C) and NOx (25 ??C) removal performance of one char compared favorably with that of a commercial activated carbon (Calgon Centaur). The NOx removal performance of the same char at 120 ??C exceeded that of the Centaur carbon by more than 1 order of magnitude. Novel char preparation methods were developed including oxidation/thermal desorption and hydrogen treatments, which increased and preserved, respectively, the active sites for SO2 and NOx adsorption. The results of combined SO2/NOx removal tests, however, suggest that SO2 and NOx compete for similar adsorption sites and SO2 seems to be more strongly adsorbed than NO. A low-activity, low-cost char was also developed for cleanup of incinerator flue gas. A three-step method involving coal preoxidation, pyrolysis, and CO2 activation was used to produce the char from Illinois coal. Five hundred pounds of the char was tested on a slipstream of flue gas from a commercial incinerator in Germany. The char was effective in removing >97% of the dioxins and furans present in the flue gas; mercury levels were below detectable limits.

  11. Heat recovery from flue gas of coal fired installations with reduced pollutant emission - the Zittau process

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, H; Strauss, R; Hofmann, K -D; Suder, M; Hultsch, T; Wetzel, W; Gabrysch, H; Jung, J [Technische Hochschule, Zittau (German Democratic Republic)

    1988-12-01

    Reviews the technology applied in the Zittau process for flue gas heat recovery and flue gas desulfurization in small brown coal fired power plants. Steam generators have a capacity of 6.5 or 10 t/h, low grade fuel with 8.2 MJ/kg calorific value is combusted. Technology has been developed on an experimental 10 t/h steam generator since 1986; an industrial 6.5 t/h prototype steam generator is now in operation achieving 95% SO{sub 2} removal from flue gas with 5600 to 7800 mg SO{sub 2} per m{sup 3} of dry flue gas. The Zittau technology is available in 3 variants: with maximum waste heat recovery, with partial waste heat recovery or without waste heat recovery and only wet flue gas scrubbing. Two flowsheets of flue gas and suspension circulation are provided. The first variant recovers 25.7% of nominal heat capacity (1.1 thermal MW from a 4.2 MW steam generator with 6.5 t/h steam capacity), the second variant recovers 6.5% of waste heat by reducing heat exchangers to 20% of the size of the first variant. Flue gas suspension scrubbing utilizes power plant ash, which is capable of absorbing 50 to 70% of SO{sub 2}, additional 25% SO{sub 2} removal is achieved by providing either 40% ash from another power plant or limestone for suspensions. Various technological details are included. 5 refs.

  12. Method and aparatus for flue gas cleaning by separation and liquefaction of sulfur dioxide and carbon dioxide

    International Nuclear Information System (INIS)

    Abdelmalek, F.T.

    1992-01-01

    This patent describes a method for recovering sulfur dioxide, carbon dioxide, and cleaning flue gases emitted from power plants. It comprises: electronically treating the flue gases to neutralize its electrostatic charges and to enhance the coagulation of its molecules and particles; exchanging sensible and latent heat of the neutralized flue gases to lower its temperature down to a temperature approaching the ambient temperature while recovering its separating the flue gas in a first stage; cooling the separated enriched carbon dioxide gas fraction, after each separation stage, while removing its vapor condensate, then compressing the enriched carbon dioxide gas fraction and simultaneously cooling the compressed gas to liquefy the sulfur dioxide gas then; allowing the sulfur dioxide gas to condense, and continuously removing the liquefied sulfur dioxide; compressing he desulfurized enriched carbon dioxide fraction to further increase its pressure, and simultaneously cooling he compressed gas to liquefy the carbon dioxide gas, then; allowing the carbon dioxide gas to condense and continuously removing the liquefied carbon dioxide; allowing the light components of the flue gas to be released in a cooling tower discharge plume

  13. Investigation and optimization of the depth of flue gas heat recovery in surface heat exchangers

    Science.gov (United States)

    Bespalov, V. V.; Bespalov, V. I.; Melnikov, D. V.

    2017-09-01

    Economic issues associated with designing deep flue gas heat recovery units for natural gas-fired boilers are examined. The governing parameter affecting the performance and cost of surface-type condensing heat recovery heat exchangers is the heat transfer surface area. When firing natural gas, the heat recovery depth depends on the flue gas temperature at the condenser outlet and determines the amount of condensed water vapor. The effect of the outlet flue gas temperature in a heat recovery heat exchanger on the additionally recovered heat power is studied. A correlation has been derived enabling one to determine the best heat recovery depth (or the final cooling temperature) maximizing the anticipated reduced annual profit of a power enterprise from implementation of energy-saving measures. Results of optimization are presented for a surface-type condensing gas-air plate heat recovery heat exchanger for the climatic conditions and the economic situation in Tomsk. The predictions demonstrate that it is economically feasible to design similar heat recovery heat exchangers for a flue gas outlet temperature of 10°C. In this case, the payback period for the investment in the heat recovery heat exchanger will be 1.5 years. The effect of various factors on the optimal outlet flue gas temperature was analyzed. Most climatic, economical, or technological factors have a minor effect on the best outlet temperature, which remains between 5 and 20°C when varying the affecting factors. The derived correlation enables us to preliminary estimate the outlet (final) flue gas temperature that should be used in designing the heat transfer surface of a heat recovery heat exchanger for a gas-fired boiler as applied to the specific climatic conditions.

  14. Influence of reaction products of K-getter fuel additives on commercial vanadia-based SCR catalysts Part II. Simultaneous addition of KCl, Ca(OH)(2), H3PO4 and H2SO4 in a hot flue gas at a SCR pilot-scale setup

    DEFF Research Database (Denmark)

    Castellino, Francesco; Jensen, Anker Degn; Johnsson, Jan Erik

    2009-01-01

    A commercial V2O5-WO3-TiO2 corrugated-type SCR monolith has been exposed for 1000 h in a pilot-scale setup to a flue gas doped with KCl, Ca(OH)(2), H3PO4 and H2SO4 by spraying a water solution of the components into the hot flue gas. The mixture composition has been adjusted in order to have P...... surface and did not proceed at the fast rates known for KCl. This fact indicates that binding K in P-K-Ca compounds is an effective way to reduce the negative influence of alkali metals on the lifetime of the vanadia-based SCR catalysts. On the other hand, P-deposition was favoured by the formation...

  15. Progress on flue gas desulfurization and denitration with electron beam irradiation in CAEP

    International Nuclear Information System (INIS)

    Ren Min; Wang Baojian; Yang Ruizhuang; Huang Wenfeng; He Xiaohai; Mao Benjiang

    2005-01-01

    The first pilot plant with electron beam irradiation for desulfurization and denitration of flue gas in China and the experimental results based on the pilot plant are briefly introduced in this paper. The FGD (flue gas desulfurization) demonstration installation designed by CAEP (China Academy of Engineering Physics) in Beijing Jingfeng Thermal Powe Co., Ltd. is recommended. (author)

  16. Organic lining materials test in flue gas ducts

    International Nuclear Information System (INIS)

    Raveh, R.; Sfez, D.; Johannsson, L.

    1998-01-01

    Corrosion protection solutions are being widely used in electric power plants equipped with Flue Gas Desulfurization (FGD) systems. Organic lining materials are one of many solutions available on the market for corrosion protection. This market segment is found in a continuous development in order to fulfill the severe demands of these materials. The main goal of this test is to obtain information about the high temperature resistance of the materials as occurs when the FGD system is by-passed. Aster initial investigation of this market segment only a few lining materials were found compatible according to their manufacturer data. Seven of these materials were installed in the outlet flue gas duct of the Israeli power station M.D. B. This power station is not equipped with a FGD system, thus it gives a real simulation of the environmental conditions into which the lining material is subjected when the FGD system is by-passed. The materials installation was observed carefully and performed by representatives from the manufacturers in order to avoid material failure due to a non-adequate application. The power station was shut down and the lining materials were inspected three and a half months after the lining materials were applied. The inspection results were good and besides changes in the lining color, most materials did not show any damages. During that time the flue gas temperature at the duct was 134?C except some temperature fluctuations

  17. Problems of flue gas desulphurization in the Matra power plants

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, I.

    1999-07-01

    Main parameters of the investment are summarized and the technology of desulphurization is outlined. The use of wet limestone in the process, the path of flue gases (sulphur dioxide, hydrogen chloride and hydrogen fluoride) from the place of burning to the dust separation unit are dealt with. Emission values are evaluated in annual average and corrosion problems related to the technology of flue gas desulphurization are discussed.

  18. A Flue Gas Tube for Thermoelectric Generator

    DEFF Research Database (Denmark)

    2013-01-01

    The invention relates to a flue gas tube (FGT) (1) for generation of thermoelectric power having thermoelectric elements (8) that are integrated in the tube. The FTG may be used in combined heat and power (CHP) system (13) to produce directly electricity from waste heat from, e.g. a biomass boiler...

  19. Water Extraction from Coal-Fired Power Plant Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Bruce C. Folkedahl; Greg F. Weber; Michael E. Collings

    2006-06-30

    The overall objective of this program was to develop a liquid disiccant-based flue gas dehydration process technology to reduce water consumption in coal-fired power plants. The specific objective of the program was to generate sufficient subscale test data and conceptual commercial power plant evaluations to assess process feasibility and merits for commercialization. Currently, coal-fired power plants require access to water sources outside the power plant for several aspects of their operation in addition to steam cycle condensation and process cooling needs. At the present time, there is no practiced method of extracting the usually abundant water found in the power plant stack gas. This project demonstrated the feasibility and merits of a liquid desiccant-based process that can efficiently and economically remove water vapor from the flue gas of fossil fuel-fired power plants to be recycled for in-plant use or exported for clean water conservation. After an extensive literature review, a survey of the available physical and chemical property information on desiccants in conjunction with a weighting scheme developed for this application, three desiccants were selected and tested in a bench-scale system at the Energy and Environmental Research Center (EERC). System performance at the bench scale aided in determining which desiccant was best suited for further evaluation. The results of the bench-scale tests along with further review of the available property data for each of the desiccants resulted in the selection of calcium chloride as the desiccant for testing at the pilot-scale level. Two weeks of testing utilizing natural gas in Test Series I and coal in Test Series II for production of flue gas was conducted with the liquid desiccant dehumidification system (LDDS) designed and built for this study. In general, it was found that the LDDS operated well and could be placed in an automode in which the process would operate with no operator intervention or

  20. Basics of ammonia slip measurement at the flue gas exit of boilers; Grundlagen zur Ammoniak-Schlupfmessung am Kesselende

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, Sascha [IBK-Verfahrenstechnik, Bad Berka (Germany); Krueger, Joerg [VWT Ing.-Buero, Schwandorf (Germany); Karau, Friedrich [Industrieberatung Karau, Wetzlar (Germany)

    2013-09-01

    When using SNCR in WtE-, biomass- and RDF combustion plants, it is not only the reduction rate of nitrogen oxide in the flue gas which is important to control but also the adherence to the limiting values for ammonia slip. Ammonia concentration in the flue gas upstream of stack is of course always in the operators' focus as limiting values have to be hold. Measuring ammonia in the flue gas downstream of boiler is not trivial due to behaviour of ammonia which occurs in bonded state (compounds) in significant amounts also at flue gas temperatures above 400 C. Ammonia compounds can occur on one hand as chemical compounds e.g. to chlorine as ammonium chlorine (chemical bonding) and on the other hand they can occur bonded to surfaces (physically adsorbed). Basic additives of the dry and quasi dry flue gas treatment cause the fractional release of bounded ammonia, therefore, after flue gas treatment, the ammonia slip can be partially measured. (orig.)

  1. Experimental study of influence characteristics of flue gas fly ash on acid dew point

    Science.gov (United States)

    Song, Jinhui; Li, Jiahu; Wang, Shuai; Yuan, Hui; Ren, Zhongqiang

    2017-12-01

    The long-term operation experience of a large number of utility boilers shows that the measured value of acid dew point is generally lower than estimated value. This is because the influence of CaO and MgO on acid dew point in flue gas fly ash is not considered in the estimation formula of acid dew point. On the basis of previous studies, the experimental device for acid dew point measurement was designed and constructed, and the acid dew point under different smoke conditions was measured. The results show that the CaO and MgO in the flue gas fly ash have an obvious influence on the acid dew point, and the content of the fly ash is negatively correlated with the temperature of acid dew point At the same time, the concentration of H2SO4 in flue gas is different, and the acid dew point of flue gas is different, and positively correlated with the acid dew point.

  2. Effect of temperature on a free energy and equilibrium constants during dry flue gas desulphurisation chemical reactions

    Directory of Open Access Journals (Sweden)

    Kuburović Miloš

    2002-01-01

    Full Text Available During dry flue gas desulphurisation (FGD dry particles of reagents are inserted (injected in the stream of flue gas, where they bond SO2. As reagents, the most often are used compounds of calcium (CaCO3, CaO or Ca(OH2. Knowledge of free energy and equilibrium constants of chemical reactions during dry FGD is necessary for understanding of influence of flue gas temperature to course of these chemical reactions as well as to SO2 bonding from flue gases.

  3. Preliminary exploitation of industrial facility for flue gas treatment

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Zimek, Z.; Iller, E.; Tyminski, B.; Licki, J.

    2001-01-01

    Full text: High emission of SO 2 and NO x in the process of fossil fuel combustion creates a major world environmental problem. Poland which uses for energy production mainly pit and brown coal produces these pollutants as well. The certain amount of SO 2 and slightly less NO x pollutants is introduced into the atmosphere. 1/2 of SO 2 and 1/3 NO x pollution is contributed by heat and electricity generating boilers. The biggest sources of pollution are located in south west side of Poland and are connected with industrial centers but over 45% of the total 802 and 69% of NO x pollutants distributed over polish territory come from external sources. The laboratory facility for flue gas treatment radiation technology was organized in Institute of Nuclear Chemistry and Technology at Warsaw at the end of 80s. Soon after the pilot plant for flue gas treatment with electron beam has been installed at Power Plant Kaweczyn near Warsaw. The flow capacity trough those installations was respectively 400 and 20000 Nm /h. Three new elements have been introduced to the construction of the radiation chamber in Polish pilot installation. Those are: cascade double stage irradiation, longitudinal irradiation, (beam scanned along the chamber axis) and the air blow under the chamber window with the purpose to create air curtain separating the window from the flue gases causing corrosion. Three different system for filtration aid has been constructed and tested: bag filter, gravel bead filter and electrostatic precipitator. The pilot plant installation was used to establish the optimal parameters of industrial facility: optimizing of the process parameters leading to reduction of energy with high efficiency of SO 2 and NO x removal; selecting and testing filter devices and filtration process; developing of the monitoring and control systems at industrial plant for flue gas cleaning, preparation of the design for industrial scale facility. The positive results of the tests performed on

  4. Numerical simulation and field test study of desulfurization wastewater evaporation treatment through flue gas.

    Science.gov (United States)

    Deng, Jia-Jia; Pan, Liang-Ming; Chen, De-Qi; Dong, Yu-Quan; Wang, Cheng-Mu; Liu, Hang; Kang, Mei-Qiang

    2014-01-01

    Aimed at cost saving and pollution reduction, a novel desulfurization wastewater evaporation treatment system (DWETS) for handling wet flue gas desulfurization (WFGD) wastewater of a coal-fired power plant was studied. The system's advantages include simple process, and less investment and space. The feasibility of this system has been proven and the appropriate position and number of nozzles, the spray droplet size and flue gas temperature limitation have been obtained by computational fluid dynamics (CFD) simulation. The simulation results show that a longer duct, smaller diameter and higher flue gas temperature could help to increase the evaporation rate. The optimal DWETS design of Shangdu plant is 100 μm droplet sprayed by two nozzles located at the long duct when the flue gas temperature is 130 °C. Field tests were carried out based on the simulation results. The effects of running DWETS on the downstream devices have been studied. The results show that DWETS has a positive impact on ash removal efficiency and does not have any negative impact on the electrostatic precipitator (ESP), flue gas heat exchanger and WFGD. The pH values of the slurry of WFGD slightly increase when the DWETS is running. The simulation and field test of the DWETS show that it is a feasible future technology for desulfurization wastewater treatment.

  5. Use of Flue Gas Desulfurization (FGD) Gypsum as a Heavy Metal Stabilizer in Contaminated Soils

    Science.gov (United States)

    Flue Gas Desulfurization (FGD) gypsum is a synthetic by-product generated from the flue gas desulfurization process in coal power plants. It has several beneficial applications such as an ingredient in cement production, wallboard production and in agricultural practice as a soil...

  6. Electron-beam flue gas treatment

    International Nuclear Information System (INIS)

    Aoki, Shinji

    1990-01-01

    A new flue gas treatment process (EBA process) using an electron beam will be discussed. This EBA process is attracting worldwide attention as a new effective measure for solving acid rain problems and jointly developed by Ebara Corporation and the Japan Atomic Energy Research Institute. This process has many advantages: a) a dry process capable of removing high level SO x and NO x simultaneously, b) a process simple and easy to operate, c) production of agricultural fertilizers as salable by-products, and d) minimal installation space. Test results from the demonstration plant (max. gas flow rate of 24,000 m 3 N/h) which was erected in a coal-fired power station in Indianapolis, Indiana, U.S.A. will be presented. (author)

  7. Process for fabrication of dry flue gas gypsum. Verfahren zur Herstellung von trockenem Rauchgasgips

    Energy Technology Data Exchange (ETDEWEB)

    Wirsching, F.; Hueller, R.; Limmer, B.

    1984-06-20

    According to the invention gypsum from flue gas wet desulfurization is dried without loss of crystallization water by a 1-4% sidestream of the flue gas in a suspended bed dryer and is subsequently separated in a cyclone. The sidestream is removed after the electrostatic precipitator, where the gas temperature is 100-130 degrees, and returned to the main gas stream prior to desulfurization, thus preventing the dehydration of the gypsum and eliminating the energy costs of reheating the gas stream to prevent acid condensation.

  8. MARKETING OF BYPRODUCT GYPSUM FROM FLUE GAS DESULFURIZATION

    Science.gov (United States)

    The report gives results of an evaluation of the 1985 marketing potential of byproduct gypsum from utility flue gas desulfurization (FGD), for the area east of the Rocky Mountains, using the calculated gypsum production rates of 14 selected power plants. The 114 cement plants and...

  9. Adsorption of mercury by activated carbon prepared from dried sewage sludge in simulated flue gas.

    Science.gov (United States)

    Park, Jeongmin; Lee, Sang-Sup

    2018-04-25

    Conversion of sewage sludge to activated carbon is attractive as an alternative method to ocean dumping for the disposal of sewage sludge. Injection of activated carbon upstream of particulate matter control devices has been suggested as a method to remove elemental mercury from flue gas. Activated carbon was prepared using various activation temperatures and times and was tested for their mercury adsorption efficiency using lab-scale systems. To understand the effect of the physical property of the activated carbon, its mercury adsorption efficiency was investigated as a function of their Brunauer-Emmett-Teller (BET) surface area. Two simulated flue gas conditions: (1) without hydrogen chloride (HCl) and (2) with 20 ppm HCl, were used to investigate the effect of flue gas composition on the mercury adsorption capacity of activated carbon. Despite very low BET surface area of the prepared sewage sludge activated carbons, their mercury adsorption efficiencies were comparable under both simulated flue gas conditions to those of pinewood and coal activated carbons. After injecting HCl into the simulated flue gas, all sewage sludge activated carbons demonstrated high adsorption efficiencies, i.e., more than 87%, regardless of their BET surface area. IMPLICATIONS We tested activated carbons prepared from dried sewage sludge to investigate the effect of their physical properties on their mercury adsorption efficiency. Using two simulated flue gas conditions, we conducted mercury speciation for the outlet gas. We found that the sewage sludge activated carbon had comparable mercury adsorption efficiency to pinewood and coal activated carbons, and the presence of HCl minimized the effect of physical property of the activated carbon on its mercury adsorption efficiency.

  10. Control and monitoring systems for electron beam flue gas treatment technology

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Licki, J.; Mazurekc, J.; Nelskic, L.; Sobolewskic, L.

    2011-01-01

    The reliable and accurate measurements of gas parameters in essential points of industrial plant are necessary for its proper operation and control. Natural flue gases there are only at the inlet. At other points of plant gas parameters are strongly modified by process control system. The principal role of process monitoring system is to provide the Computer System for Monitoring and Control with continuous recording of process parameters. The main goal of control system is to obtain the optimal SO 2 and NO x removal efficiencies by control of amount of spray water at the spray cooler, amount of NH 3 injection to flue gas and adjustment of electron beam current. The structure of the process control system is based on algorithms describing functional dependence of SO 2 and NO x removal efficiencies. The best available techniques should be applied for measurements of flue gases parameters at essential points of installation and for digital control system to assist plant operators in the analysis and optimization of plant operation, including integrated emission control. (author)

  11. Control and monitoring systems for electron beam flue gas treatment technology

    Energy Technology Data Exchange (ETDEWEB)

    Chmielewski, A. G. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland); Licki, J. [Institute of Atomic Energy, Otwock-Świerk (Poland); Mazurekc, J.; Nelskic, L.; Sobolewskic, L. [Dolna Odra Group, Pomorzany Power Plant, Szczecin (Poland)

    2011-07-01

    The reliable and accurate measurements of gas parameters in essential points of industrial plant are necessary for its proper operation and control. Natural flue gases there are only at the inlet. At other points of plant gas parameters are strongly modified by process control system. The principal role of process monitoring system is to provide the Computer System for Monitoring and Control with continuous recording of process parameters. The main goal of control system is to obtain the optimal SO{sub 2} and NO{sub x} removal efficiencies by control of amount of spray water at the spray cooler, amount of NH{sub 3} injection to flue gas and adjustment of electron beam current. The structure of the process control system is based on algorithms describing functional dependence of SO{sub 2} and NO{sub x} removal efficiencies. The best available techniques should be applied for measurements of flue gases parameters at essential points of installation and for digital control system to assist plant operators in the analysis and optimization of plant operation, including integrated emission control. (author)

  12. Process for the removal of sulfur oxides and nitrogen oxides from flue gas

    International Nuclear Information System (INIS)

    Elshout, R.V.

    1992-01-01

    This patent describes a continuous process for removing sulfur oxide and nitrogen oxide contaminants from the flue gas generated by industrial power plants and boiler systems burning sulfur containing fossil fuels and for converting these contaminants, respectively, into recovered elemental liquid sulfur and nitrogen ammonia and mixtures thereof. It comprises removing at least a portion of the flue gas generated by a power plant or boiler system upstream of the stack thereof; passing the cooled and scrubbed flue gas through an adsorption system; combining a first portion of the reducing gas stream leaving the adsorbers of the adsorption system during regeneration thereof and containing sulfur oxide and nitrogen oxide contaminants with a hydrogen sulfide rich gas stream at a temperature of about 400 degrees F to about 600 degrees F and passing the combined gas streams through a Claus reactor-condenser system over a catalyst in the reactor section thereof which is suitable for promoting the equilibrium reaction between the hydrogen sulfide and the sulfur dioxide of the combined streams to form elemental sulfur

  13. The Coupling Effect Research of Ash Deposition and Condensation in Low Temperature Flue Gas

    Directory of Open Access Journals (Sweden)

    Lei Ma

    2016-01-01

    Full Text Available Ash deposition is a key factor that deteriorates the heat transfer performance and leads to higher energy consumption of low pressure economizer working in low temperature flue gas. In order to study the ash deposition of heat exchange tubes in low temperature flue gas, two experiments are carried out with different types of heat exchange tubes in different flue gas environments. In this paper, Nusselt Number Nu and fouling factor ε are calculated to describe the heat transfer characteristics so as to study the ash deposition condition. The scanning electron microscope (SEM is used for the analysis of ash samples obtained from the outer wall of heat exchange tubes. The dynamic process of ash deposition is studied under different temperatures of outer wall. The results showed that ash deposition of heat exchanger will achieve a stable state in constant flue gas environment. According to the condition of condensation of acid vapor and water vapor, the process of ash deposition can be distinguished as mere ash deposition, acid-ash coupling deposition, and acid-water-ash coupling deposition.

  14. Purification of coal fired boiler flue gas and fertilizer production by using electron beam

    International Nuclear Information System (INIS)

    Maezawa, Akihiko

    1996-01-01

    Electron beam irradiation technology which is applied in electron accelerators is used in a variety of fields, including industry, medicine and etc.. In collaboration with the Japan Atomic Energy Research Institute, Ebara Corporation has developed a novel flue-gas treatment process by making use of the electron beam for the purification of flue gas emitted from industrial plant such as thermal power station. The E-beam flue gas treatment process (EBA Process) is applied to clean flue gas generated in the combustion of coal containing sulfur oxides (SOx) and nitrogen oxides (NOx), which are chemical pollutants responsible for acid rain. As a by-product of this process, ammonium sulfate and ammonium nitrate mixture is obtained. This mixture can be recovered from the process as a valuable fertilizer to promote the growth of agricultural produce. The EBA process thus serves two important purposes at the same time: It helps prevent environmental pollution and produces a fertilizer that is vitally important for increasing food production to meet the world's future population growth. (J.P.N.)

  15. Thief process for the removal of mercury from flue gas

    Science.gov (United States)

    Pennline, Henry W.; Granite, Evan J.; Freeman, Mark C.; Hargis, Richard A.; O'Dowd, William J.

    2003-02-18

    A system and method for removing mercury from the flue gas of a coal-fired power plant is described. Mercury removal is by adsorption onto a thermally activated sorbent produced in-situ at the power plant. To obtain the thermally activated sorbent, a lance (thief) is inserted into a location within the combustion zone of the combustion chamber and extracts a mixture of semi-combusted coal and gas. The semi-combusted coal has adsorptive properties suitable for the removal of elemental and oxidized mercury. The mixture of semi-combusted coal and gas is separated into a stream of gas and semi-combusted coal that has been converted to a stream of thermally activated sorbent. The separated stream of gas is recycled to the combustion chamber. The thermally activated sorbent is injected into the duct work of the power plant at a location downstream from the exit port of the combustion chamber. Mercury within the flue gas contacts and adsorbs onto the thermally activated sorbent. The sorbent-mercury combination is removed from the plant by a particulate collection system.

  16. Demonstration test of electron beam flue gas treatment pilot plant of a coal fired thermal power station

    International Nuclear Information System (INIS)

    Doi, Yoshitaka; Hayashi, Kazuaki; Izutsu, Masahiro; Watanabe, Shigeharu; Namba, Hideki; Tokunaga, Okihiro; Hashimoto, Shoji; Tanaka, Tadashi; Ogura, Yoshimi.

    1995-01-01

    The Japan Atomic Energy Research Institute, Chubu Electric Power Company and Ebara Corporation jointly constructed a pilot plant for electron beam flue gas treatment (dry process) capable of treating 12,000 m 3 /h (NTP) of flue gas from a coal fired boiler, at Shin-Nagoya Thermal Power Station, Chubu Electric Power Company. Various tests carried out at the plant over a period extending one year verified the followings. By appropriately controlling parameters such as electron beam dosage, flue gas temperature, and ammonia stoichiometric amount, highly efficient simultaneous SO 2 and NOx removal from flue gas was achieved under all gas conditions, equal to or more efficient than that by the highest level conventional treatment. The operation of the pilot plant was stable and trouble-free over a long term, and the operation and the process was easy to operate and control. By-products (ammonium sulfate and ammonium nitrate) produced by the flue gas treatment were proven to have superior quality, equivalent to that of market-available nitrogen fertilizers. These by-products had been registered as by-product nitrogen fertilizers. (author)

  17. The use of flue gas for the growth of microalgal biomass

    International Nuclear Information System (INIS)

    Zeiler, K.G.; Kadam, K.L.; Heacox, D.A.

    1995-01-01

    Capture and utilization of carbon dioxide (CO 2 ) by microalgae is a promising technology to help reduce emissions from fossil fuel-fired power plants. Microalgae are of particular interest because of their rapid growth rates and tolerance to varying environmental conditions. Laboratory work is directed toward investigating the effects of simulated flue gas on microalgae, while engineering studies have focused on the economics of the technology. One strain of a green algae, Monoraphidium minutum, has shown excellent tolerance and growth when exposed to simulated flue gas which meets the requirements of the 1990 Clean Air Act Amendments (1990 CAAA). Biomass concentrations of ∼2g/L have been measured in batch culture. Several other microalgae have also shown tolerance to simulated flue gas; however, the growth of these strains is not equivalent to that observed for M. minutum. Coupling the production of biodiesel or other microalgae-derived commodity chemicals with the use of flue gas carbon dioxide is potentially a zero-cost method of reducing the amount of carbon dioxide contributed to the atmosphere by fossil fuel-fired power plants. We have identified two major biological performance parameters which can provide sufficient improvement in this technology to render it cost-competitive with other existing CO x mitigation technologies. These are algal growth rate and lipid content. An updated economic analysis shows that growth rate is the more important of the two, and should be the focus of near term research activities. The long term goal of achieving zero cost will require other, non-biological, improvements in the process

  18. The use of flue gas for the growth of microalgal biomass

    Energy Technology Data Exchange (ETDEWEB)

    Zeiler, K.G.; Kadam, K.L.; Heacox, D.A. [National Renewable Energy Lab., Golden, CO (United States)] [and others

    1995-11-01

    Capture and utilization of carbon dioxide (CO{sub 2}) by microalgae is a promising technology to help reduce emissions from fossil fuel-fired power plants. Microalgae are of particular interest because of their rapid growth rates and tolerance to varying environmental conditions. Laboratory work is directed toward investigating the effects of simulated flue gas on microalgae, while engineering studies have focused on the economics of the technology. One strain of a green algae, Monoraphidium minutum, has shown excellent tolerance and growth when exposed to simulated flue gas which meets the requirements of the 1990 Clean Air Act Amendments (1990 CAAA). Biomass concentrations of {similar_to}2g/L have been measured in batch culture. Several other microalgae have also shown tolerance to simulated flue gas; however, the growth of these strains is not equivalent to that observed for M. minutum. Coupling the production of biodiesel or other microalgae-derived commodity chemicals with the use of flue gas carbon dioxide is potentially a zero-cost method of reducing the amount of carbon dioxide contributed to the atmosphere by fossil fuel-fired power plants. We have identified two major biological performance parameters which can provide sufficient improvement in this technology to render it cost-competitive with other existing CO{sub x} mitigation technologies. These are algal growth rate and lipid content. An updated economic analysis shows that growth rate is the more important of the two, and should be the focus of near term research activities. The long term goal of achieving zero cost will require other, non-biological, improvements in the process.

  19. Confined zone dispersion flue gas desulfurization demonstration. Quarterly report No. 8, August 17, 1992--November 16, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-27

    The CZD process involves injecting a finely atomized slurry of reactive lime into the flue gas duct work of a coal-fired utility boiler. The principle of the confined zone is to form a wet zone of slurry droplets in the middle of the duct confined in an envelope of hot gas between the wet zone and the duct walls. The lime slurry reacts with part of the SO{sub 2} in the gas, and the reaction products dry to form solid particles. A solids collector, typically an electrostatic precipitator (ESP) downstream from the point of injection, captures the reaction products along with the fly ash entrained in the flue gas. The goal of this demonstration is to prove the technical and economic feasibility of the CZD technology on a commercial scale. The process is expected to achieve 50% SO{sub 2} removal at lower capital and O&M costs than other systems. To achieve its objectives, the project is divided into the following three phases: Phase 1: Design and Permitting, Phase 2: Construction and Start-up, Phase 3: Operation and Disposition. Phase 1 activities were completed on January 31, 1991. Phase 2 activities were essentially concluded on July 31, 1991, and Phase 3a, Parametric Testing, was initiated on July 1, 1991. This Quarterly Technical Progress Report covers Phase 3b activities from August 17, 1992 through November 16, 1992.

  20. Power by waste heat recovery from low temperature industrial flue gas by Organic Flash Cycle (OFC) and transcritical-CO_2 power cycle: A comparative study through combined thermodynamic and economic analysis

    International Nuclear Information System (INIS)

    Mondal, Subha; De, Sudipta

    2017-01-01

    Both Organic flash cycle and transcritical CO_2 power cycle (T-CO_2 power cycle) allow cooling of hot flue gas stream to an appreciably lower temperature due to the absence of pinch limitation. In the present study, a combined thermodynamic and economic comparison is conducted between a T-CO_2 power cycle and Organic flash cycles using R-245fa and R600 as the working fluids. It is observed that work output per kg of flue gas flow rate is slightly higher for the T-CO_2 power cycle if the flue gas is allowed to cool to the corresponding lowest possible temperature in the Heat Recovery Unit (HRU). It is also observed that with maximum possible cooling of flue gas, minimum bare module costs (BMCs) for each kW power output of OFCs are somewhat higher compared to that of T-CO_2 power cycle. Minimum BMCs for each kW output of OFCs can be reduced substantially by increasing terminal temperature difference at the low temperature end of the HRU. However, the increasing terminal temperature difference at the low temperature end of the HRU is having negligible effect on BMC ($/kW) of T-CO_2 power cycle. - Highlights: • Combined thermodynamic and economic analysis done for T-CO_2 power cycle and OFC. • With highest heat recovery, T-CO_2 cycle produces slightly higher work output/kg of flue gas. • With highest heat recovery, minimum bare module costs in $/kW is slightly higher for OFCs. • Work outputs/kg of flue gas of all cycles are almost equal for these minimum BMCs. • BMCs in $/kW for OFCs sharply decrease with larger flue gas exit temperature.

  1. Control systems for condensing flue-gas coolers related to natural-gas-fired heating plants

    International Nuclear Information System (INIS)

    Krighaar, M.; Paulsen, O.

    1992-01-01

    A theoretical study is made of the enthalpy-efficiency for a water-cooled heat exchanger added to a natural gas-fired boiler. Under varying conditions of both water flow and temperature and flue-gas flow and temperature, both in condensing and non-condensing mode, the efficiency seems to be constant. The result is very useful for comparison between two different working conditions. The efficiency is used to calculate the savings achieved for a district heating plant by using a heat exchanger. The energy economic calculations are also helpful for estimating the most appropriate size of heat exchanger. The annual savings are calculated by means of data regarding heat production, flue gas temperature and water return temperature. The savings achieved by using different connection principles such as bypass, reheating and controlled water temperature are also calculated. (author)

  2. Biological (flue) gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Buisman, C.J.N.; Dijkman, H. [PAQUES, Balk (Netherlands); Prins, W.L.; Verbraak, P. [Biostar CV, Balk (Netherlands); Den Hartog, A.J. [Hoogovens Groep BV, IJmuiden (Netherlands)

    1995-12-31

    Biotechnological research has been carried out to find new micro-organisms and processes to make useful products, and to reveal new ways and biotechnological mechanisms to produce elemental sulfur in waste water treatment. Biotechnological development work has been carried out and the first commercial installation (on 300 m{sup 3}/hr scale) to produce sulfur from polluted waste water was started up in 1992. The importance of this recent research and development in the area of waste water treatment was recognized. In an intensive cooperation between Hoogovens Technical Services and PACQUES the concept for a totally new Biological Flue Gas Desulfurization process (BIO-FGD), producing sulfur as by-product, was invented. It consists of the combination of a sodium scrubber with two biological reactors resulting in a very attractive new concept for a gas cleaning process. A description of the process is given and the pilot plant results are outlined. 4 figs., 5 refs.

  3. Electron beam flue gas treatment process. Review

    International Nuclear Information System (INIS)

    Honkonen, V.A.

    1996-01-01

    The basis of the process for electron beam flue gas treatment are presented in the report. In tabular form the history of the research is reviewed. Main dependences of SO 2 and NO x removal efficiencies on different physico-chemical parameters are discussed. Trends concerning industrial process implementation are presented in the paper,finally. (author). 74 refs, 11 figs, 1 tab

  4. Workshop on sulfur chemistry in flue gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Wallace, W.E. Jr.

    1980-05-01

    The Flue Gas Desulfurization Workshop was held at Morgantown, West Virginia, June 7-8, 1979. The presentations dealt with the chemistry of sulfur and calcium compounds in scrubbers. DOE and EPRI programs in this area are described. Ten papers have been entered individually into EDB and ERA. (LTN)

  5. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Edward Levy; Harun Bilirgen; John DuPoint

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: (1) An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing high-moisture, low rank coals. (2) Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. (3) Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. (4) Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. (5) Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. (6) Condensed flue gas water treatment needs and costs. (7) Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. (8) Results of cost-benefit studies of condensing heat exchangers.

  6. Recovery of Water from Boiler Flue Gas Using Condensing Heat Exchangers

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Edward; Bilirgen, Harun; DuPont, John

    2011-03-31

    Most of the water used in a thermoelectric power plant is used for cooling, and DOE has been focusing on possible techniques to reduce the amount of fresh water needed for cooling. DOE has also been placing emphasis on recovery of usable water from sources not generally considered, such as mine water, water produced from oil and gas extraction, and water contained in boiler flue gas. This report deals with development of condensing heat exchanger technology for recovering moisture from flue gas from coal-fired power plants. The report describes: • An expanded data base on water and acid condensation characteristics of condensing heat exchangers in coal-fired units. This data base was generated by performing slip stream tests at a power plant with high sulfur bituminous coal and a wet FGD scrubber and at a power plant firing highmoisture, low rank coals. • Data on typical concentrations of HCl, HNO{sub 3} and H{sub 2}SO{sub 4} in low temperature condensed flue gas moisture, and mercury capture efficiencies as functions of process conditions in power plant field tests. • Theoretical predictions for sulfuric acid concentrations on tube surfaces at temperatures above the water vapor dewpoint temperature and below the sulfuric acid dew point temperature. • Data on corrosion rates of candidate heat exchanger tube materials for the different regions of the heat exchanger system as functions of acid concentration and temperature. • Data on effectiveness of acid traps in reducing sulfuric acid concentrations in a heat exchanger tube bundle. • Condensed flue gas water treatment needs and costs. • Condensing heat exchanger designs and installed capital costs for full-scale applications, both for installation immediately downstream of an ESP or baghouse and for installation downstream of a wet SO{sub 2} scrubber. • Results of cost-benefit studies of condensing heat exchangers.

  7. Fluoroplastic materials for pressure tubes in flue gas heat exchangers under corrosive conditions of flue gas desulfurisation plants; Fluorkunststoffe fuer Druckrohre in Rauchgaswaermetauschern unter korrosiven Bedingungen fuer die Rauchgasentschwefelung

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk-Gaudig, Gabriele [Dyneon GmbH, Burgkirchen (Germany); Broda, Siegfried [Heatec Co., Ltd., Chonburi (Thailand); Adamczyk, Frank; Kreilos, Klaus [Babcock Borsig Service GmbH, Oberhausen (Germany). Bereich Waermenutzung

    2010-07-01

    Since the 1980s, power plants have been required to have flue gas desulphurising plants. For the cooling of flue gases to below the acid dew point and subsequent reheating, corrosion-resistant gas-gas heat exchanger systems had already been developed at this time by what is now Babcock Borsig Service GmbH (BBS). The best results were achieved using 100 % plastic piping as a vital component. In addition to the development of the plastic heat exchangers and the differences in design relative to alternative models, the various types of fluoroplastics will be discussed, and in particular the difference between PFA and PTFE. (orig.)

  8. CH4 recovery and CO2 sequestration using flue gas in natural gas hydrates as revealed by a micro-differential scanning calorimeter

    International Nuclear Information System (INIS)

    Lee, Yohan; Kim, Yunju; Lee, Jaehyoung; Lee, Huen; Seo, Yongwon

    2015-01-01

    Highlights: • The extent of the replacement was improved due to the enclathration of N 2 in small cages. • The dissociation enthalpies of the replaced gas hydrates were measured. • There was no noticeable heat flow change during the CH 4 –flue gas replacement. • The replacement could occur without significant destruction of gas hydrates. - Abstract: The CH 4 –flue gas replacement in naturally occurring gas hydrates has attracted significant attention due to its potential as a method of exploitation of clean energy and sequestration of CO 2 . In the replacement process, the thermodynamic and structural properties of the mixed gas hydrates are critical factors to predict the heat flow in the hydrate-bearing sediments and the heat required for hydrate dissociation, and to evaluate the CO 2 storage capacity of hydrate reservoirs. In this study, the 13 C NMR and gas composition analyses confirmed that the preferential enclathration of N 2 molecules in small 5 12 cages of structure I hydrates improved the extent of the CH 4 recovery. A high pressure micro-differential scanning calorimeter (HP μ-DSC) provided reliable hydrate stability conditions and heat of dissociation values in the porous silica gels after the replacement, which confirmed that CH 4 in the hydrates was successfully replaced with flue gas. A heat flow change associated with the dissociation and formation of hydrates was not noticeable during the CH 4 –flue gas replacement. Therefore, this study reveals that CH 4 –flue gas swapping occurs without structural transitions and significant hydrate dissociations

  9. Flue gas moisture capacity calculation at the outlet of the condensation heat recovery unit

    Directory of Open Access Journals (Sweden)

    Galashov Nikolay

    2017-01-01

    Full Text Available As a result, study equation has been obtained which determine the flue gas moisture capacity at the outlet of the condensation heat recovery unit with an error of less than 1%. It possible to at the temperature of the flue gas below the dew point and the known air-fuel ratio efficient. The equation can be used to calculate plants operating on products of gas combustion without Use of tables and programs for calculating the water-vapor saturation pressure.

  10. Adsorption separation of carbon dioxide from flue gas by a molecularly imprinted adsorbent.

    Science.gov (United States)

    Zhao, Yi; Shen, Yanmei; Ma, Guoyi; Hao, Rongjie

    2014-01-01

    CO2 separation by molecularly imprinted adsorbent from coal-fired flue gas after desulfurization system has been studied. The adsorbent was synthesized by molecular imprinted technique, using ethanedioic acid, acrylamide, and ethylene glycol dimethacrylate as the template, functional monomer, and cross-linker, respectively. According to the conditions of coal-fired flue gas, the influencing factors, including adsorption temperature, desorption temperature, gas flow rate, and concentrations of CO2, H2O, O2, SO2, and NO, were studied by fixed bed breakthrough experiments. The experimental conditions were optimized to gain the best adsorption performance and reduce unnecessary energy consumption in future practical use. The optimized adsorption temperature, desorption temperature, concentrations of CO2, and gas flow rate are 60 °C, 80 °C, 13%, and 170 mL/min, respectively, which correspond to conditions of practical flue gases to the most extent. The CO2 adsorption performance was nearly unaffected by H2O, O2, and NO in the flue gas, and was promoted by SO2 within the emission limit stipulated in the Chinese emission standards of air pollutants for a thermal power plant. The maximum CO2 adsorption capacity, 0.57 mmol/g, was obtained under the optimized experimental conditions, and the SO2 concentration was 150 mg/m(3). The influence mechanisms of H2O, O2, SO2, and NO on CO2 adsorption capacity were investigated by infrared spectroscopic analysis.

  11. FTIR analysis of flue gases - combined in-situ and dry extractive gas sampling; Kombination av in-situ och kallextraktiv roekgasmaetning med FTIR

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Christer; Soederbom, J [Vattenfall Utveckling AB, Aelvkarleby (Sweden)

    1996-10-01

    Fourier Transform Infra Red (FTIR) spectroscopy is a promising and versatile technique for gas analysis which lately has moved from the laboratory to industrial applications such as emission monitoring of combustion plants. This has been made possible by recent developments of spectrometers and software. The single most important advantage of the FTIR is its capability to simultaneously analyse virtually all gas species of interest in flue gas applications. The project has studied the feasibility of using the technique as a multi-component emission monitoring system. A specific aim was to evaluate different implementations of the technique to flue gas analysis: in-situ, hot/dry and cold extraction or combinations of these. The goal was to demonstrate a system in which gas components that normally require hot extraction (NH{sub 3}, HCl, H{sub 2}O) could instead be measured in-situ. In this way potential sampling artefacts e.g. for ammonia monitoring, can be avoided. The remaining gas components are measured using cold extraction and thereby minimizing interference from water. The latter advantage can be crucial for the accuracy of e.g. NO{sub x} measurements. Prior to the project start in-situ monitoring using FTIR was, a to a large extent, an untried method. The fact that broad band IR radiation can not be guided through optical fibres, presented a major technical obstacle. An `in-situ probe` was developed to serve the purpose. The probe is equipped with a gold plated mirror at the end and is mounted on the support structure of the FTIR-spectrometer. The arrangement proved to be a robust solution without being unnecessary complex or cumbersome to use. 10 refs, 45 figs, 10 tabs

  12. Japan’s experience of flue gas treatment by electron beams

    International Nuclear Information System (INIS)

    Machi, S.

    2011-01-01

    The electron beam flue gas treatment technology was invented in Japan in 1970's. The paper presents the outlook of the Japanese activities on the development and present state of EBFGT technology. (author)

  13. Japan’s experience of flue gas treatment by electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Machi, S.

    2011-07-01

    The electron beam flue gas treatment technology was invented in Japan in 1970's. The paper presents the outlook of the Japanese activities on the development and present state of EBFGT technology. (author)

  14. Performance evaluation of non-thermal plasma injection for elemental mercury oxidation in a simulated flue gas

    Energy Technology Data Exchange (ETDEWEB)

    An, Jiutao; Shang, Kefeng; Lu, Na [Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian 116024 (China); Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education of the People' s Republic of China, Dalian 116024 (China); Jiang, Yuze [Shandong Electric Power Research Institute, Jinan 250002 (China); Wang, Tiecheng [Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian 116024 (China); Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education of the People' s Republic of China, Dalian 116024 (China); Li, Jie, E-mail: lijie@dlut.edu.cn [Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian 116024 (China); Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education of the People' s Republic of China, Dalian 116024 (China); Wu, Yan [Institute of Electrostatics and Special Power, Dalian University of Technology, Dalian 116024 (China); Key Laboratory of Industrial Ecology and Environmental Engineering, Ministry of Education of the People' s Republic of China, Dalian 116024 (China)

    2014-03-01

    Graphical abstract: - Highlights: • The use of non-thermal plasma injection approach to oxidize Hg{sup 0} in simulated flue gas at 110 °C was studied. • A high Hg{sup 0} oxidation efficiency was observed in the mixed flue gas that included O{sub 2}, H{sub 2}O, SO{sub 2}, NO and HCl. • Chemical and physical processes (e.g., ozone, N{sub 2} metastable states and UV-light) contributed to Hg{sup 0} oxidation. • Mercury species mainly existed in the form of HgO(s) adhering to the suspended aerosols in the gas-phase. - Abstract: The use of non-thermal plasma (NTP) injection approach to oxidize elemental mercury (Hg{sup 0}) in simulated flue gas at 110 °C was studied, where a surface discharge plasma reactor (SDPR) inserted in the simulated flue duct was used to generate and inject active species into the flue gas. Approximately 81% of the Hg{sup 0} was oxidized and 20.5 μg kJ{sup −1} of energy yield was obtained at a rate of 3.9 J L{sup −1}. A maximal Hg{sup 0} oxidation efficiency was found with a change in the NTP injection air flow rate. A high Hg{sup 0} oxidation efficiency was observed in the mixed flue gas that included O{sub 2}, H{sub 2}O, SO{sub 2}, NO and HCl. Chemical and physical processes (e.g., ozone, N{sub 2} metastable states and UV-light) were found to contribute to Hg{sup 0} oxidation, with ozone playing a dominant role. The deposited mercury species on the internal surface of the flue duct was analyzed using X-ray photoelectron spectroscopy (XPS) and electronic probe microanalysis (EPMA), and the deposit was identified as HgO. The mercury species is thought to primarily exist in the form of HgO(s) by adhering to the suspended aerosols in the gas-phase.

  15. Influence of carbonation under oxy-fuel combustion flue gas on the leachability of heavy metals in MSWI fly ash.

    Science.gov (United States)

    Ni, Peng; Xiong, Zhuo; Tian, Chong; Li, Hailong; Zhao, Yongchun; Zhang, Junying; Zheng, Chuguang

    2017-09-01

    Due to the high cost of pure CO 2 , carbonation of MSWI fly ash has not been fully developed. It is essential to select a kind of reaction gas with rich CO 2 instead of pure CO 2 . The CO 2 uptake and leaching toxicity of heavy metals in three typical types of municipal solid waste incinerator (MSWI) fly ash were investigated with simulated oxy-fuel combustion flue gas under different reaction temperatures, which was compared with both pure CO 2 and simulated air combustion flue gas. The CO 2 uptake under simulated oxy-fuel combustion flue gas were similar to that of pure CO 2 . The leaching concentration of heavy metals in all MSWI fly ash samples, especially in ash from Changzhou, China (CZ), decreased after carbonation. Specifically, the leached Pb concentration of the CZ MSWI fly ash decreased 92% under oxy-fuel combustion flue gas, 95% under pure CO 2 atmosphere and 84% under the air combustion flue gas. After carbonation, the leaching concentration of Pb was below the Chinese legal limit. The leaching concentration of Zn from CZ sample decreased 69% under oxy-fuel combustion flue gas, which of Cu, As, Cr and Hg decreased 25%, 33%, 11% and 21%, respectively. In the other two samples of Xuzhou, China (XZ) and Wuhan, China (WH), the leaching characteristics of heavy metals were similar to the CZ sample. The speciation of heavy metals was largely changed from the exchangeable to carbonated fraction because of the carbonation reaction under simulated oxy-fuel combustion flue gas. After carbonation reaction, most of heavy metals bound in carbonates became more stable and leached less. Therefore, oxy-fuel combustion flue gas could be a low-cost source for carbonation of MSWI fly ash. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Flue gas cleaning by electron beam technology in 21st

    International Nuclear Information System (INIS)

    Xu Guang; Luo Jingyu; Zhang Ming

    2005-01-01

    China is paying great attention to the pollution caused by flue gases including sulfur oxides, nitrogen oxides, fine particles, and volatile organic compounds (VOC) for the environmental protection and sustainable development of China economy for 21st century. Among several promising processes, applicable to industrial scale, the electron beam (EB) scrubbing process can simultaneously remove SO 2 , NOx, PM-10 (particulate matter 10 μm or less in diameter), VOC and CO 2 from the flue gas is a new high technology combined with radiation chemistry and electron accelerator technique. The EB flue gas purification process consists of the producing ionization in the EB irradiated gases followed by the formation of free radicals and active species which ultimately forming foggy sulfur acid and nitrate acid. These acids react further with added ammonia to form ammonium sulfate and nitrates as by-products, which can be fertilizer usable in agriculture. The next stage for this technology is its optimization for the reduction of electricity energy consumption and an effective collection of by-products. Lastly the investment cost for EB method is shown to be the most economic compared with other competing methods. (S. Ohno)

  17. A thermodynamic approach on vapor-condensation of corrosive salts from flue gas on boiler tubes in waste incinerators

    International Nuclear Information System (INIS)

    Otsuka, Nobuo

    2008-01-01

    Thermodynamic equilibrium calculation was conducted to understand the effects of tube wall temperature, flue gas temperature, and waste chemistry on the type and amount of vapor-condensed 'corrosive' salts from flue gas on superheater and waterwall tubes in waste incinerators. The amount of vapor-condensed compounds from flue gases at 650-950 deg. C on tube walls at 350-850 deg. C was calculated, upon combustion of 100 g waste with 1.6 stoichiometry (in terms of the air-fuel ratio). Flue gas temperature, rather than tube wall temperature, influenced the deposit chemistry of boiler tubes significantly. Chlorine, sulfur, sodium, potassium, and calcium contents in waste affected it as well

  18. Hg⁰ removal from flue gas by ionic liquid/H₂O₂.

    Science.gov (United States)

    Cheng, Guangwen; Bai, Bofeng; Zhang, Qiang; Cai, Ming

    2014-09-15

    1-Alkyl-3-methylimidazolium chloride ionic liquids ([Cnmim] Cl, n=4, 6, 8) were prepared. The ionic liquid was then mixed with hydrogen peroxide (H2O2) to form an absorbent. The Hg(0) removal performance of the absorbent was investigated in a gas/liquid scrubber using simulated flue gas. It was found that the ionic liquid/H2O2 mixture was an excellent absorbent and could be used to remove Hg(0) from flue gas. When the mass ratio of H2O2 to ionic liquid was 0.5, the absorbent showed high Hg(0) removal efficiency (up to 98%). The Hg(0) removal efficiency usually increased with the absorption temperature, while decreased with the increase of alkyl chain length in ionic liquid molecule. The Hg(0) removal mechanism involved with Hg(0) oxidation by H2O2 and Hg(2+) transfer from aqueous phase to ionic liquid phase. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Handwriting on the power plant wall: flue gas treatment

    Energy Technology Data Exchange (ETDEWEB)

    Troupe, J.S.

    1979-08-01

    This paper reviews the present state of flue gas treatment technology. Describes the operation of four basic types of devices used by electric utilities:- mechanical dust collectors, electrostatic precipitators, wet scrubbers and fabric filters. Considers their reliability and cost, and outlines possible future trends.

  20. Flue gas conditioning for improved particle collection in electrostatic precipitators

    Energy Technology Data Exchange (ETDEWEB)

    Durham, M.D.

    1992-04-27

    The purpose of this research program is to identify and evaluate a variety of additives capable of increasing particle cohesion which could be used for improving collection efficiency in an ESP. A three-phase screening process will be used to provide the, evaluation of many additives in a logical and cost-effective manner. The three step approach involves the following experimental setups: 1. Provide a preliminary screening in the laboratory by measuring the effects of various conditioning agents on reentrainment of flyash particles in an electric field operating at simulated flue gas conditions. 2. Evaluate the successful additives using a 100 acfm bench-scale ESP operating on actual flue gas. 3. Obtain the data required for scaling up the technology by testing the two or three most promising conditioning agents at the pilot scale.

  1. The effectiveness of recirculating flue gasses on a gas-fuel oil boiler unit with hearth burners

    Energy Technology Data Exchange (ETDEWEB)

    Eremeev, V V; Kovalenko, A L; Kozlov, V G

    1981-01-01

    The results of investigating the effect of recirculating flue gasses on a TP-87 boiler (D = 420 tons per hour, 14 MPa, 560 C) with a hearth composition of four gas-fuel oil burners are presented. The heat-release rate of the volume of the furnace is 136 Kw per m/sup 3/; that if a cross section of the combustion chamber is 3.2 MW/m/sup 2/. The hot air temperature is 420 C. The tests were carried out during the combustion of M-100 petroleum oil which has a moisture content of 3 / 4% and a sulfur content of 2.4%. The pressure of the oil against the mechanical sprayers is 2.9-3.0 MPa at the rated load; the temperature is 125-130 C. The recirculation of the flue gasses was organized in order to expand the regulatory stress range and decrease the discharge of nitric oxides into the atmosphere. Moreover, flue gasses with a temperature of 330-370/sup 0/C were removed from a first-degree BE gas conduit, and, using two BGD-15.5 type exhaust fans, were fed into the annular channels around the burners. The calculated velocity of the gasses at the output of the burner is equal to 35 M/s; the air velocity is 64 M/s. It is shown that the TP-87 furnace--with fuel oil hearth burners and recirculation to obtain flue gasses into independent burner ducts--makes it possible to obtain a useful stress range during almost complete fuel oil combustion with minimal air exceses by maintaining the calculated temperature of the superheated vapor. Recirculating flue gasses in a duct around the burners constitutes an effective means of decreasing the discharge of nitric oxides, and of decreasing local heat stress on the screens. However, increasing the recirculation coefficient to 0.17 causes a 0.35% increase in the loss of heat with the departing gasses (the temperature of which increases by 7 C), and a 0.15% decrease in the heat flow rate for SN, which leads to an overall drop of approx. 0.5% in the efficiency coefficient of the boiler.

  2. Modeling and parametric analysis of hollow fiber membrane system for carbon capture from multicomponent flue gas

    KAUST Repository

    Khalilpour, Rajab

    2011-08-12

    The modeling and optimal design/operation of gas membranes for postcombustion carbon capture (PCC) is presented. A systematic methodology is presented for analysis of membrane systems considering multicomponent flue gas with CO 2 as target component. Simplifying assumptions is avoided by namely multicomponent flue gas represented by CO 2/N 2 binary mixture or considering the co/countercurrent flow pattern of hollow-fiber membrane system as mixed flow. Optimal regions of flue gas pressures and membrane area were found within which a technoeconomical process system design could be carried out. High selectivity was found to not necessarily have notable impact on PCC membrane performance, rather, a medium selectivity combined with medium or high permeance could be more advantageous. © 2011 American Institute of Chemical Engineers (AIChE).

  3. Reaction behavior of SO2 in the sintering process with flue gas recirculation.

    Science.gov (United States)

    Yu, Zhi-Yuan; Fan, Xiao-Hui; Gan, Min; Chen, Xu-Ling; Chen, Qiang; Huang, Yun-Song

    2016-07-01

    The primary goal of this paper is to reveal the reaction behavior of SO2 in the sinter zone, combustion zone, drying-preheating zone, and over-wet zone during flue gas recirculation (FGR) technique. The results showed that SO2 retention in the sinter zone was associated with free-CaO in the form of CaSO3/CaSO4, and the SO2 adsorption reached a maximum under 900ºC. SO2 in the flue gas came almost from the combustion zone. One reaction behavior was the oxidation of sulfur in the sintering mix when the temperature was between 800 and 1000ºC; the other behavior was the decomposition of sulfite/sulfate when the temperature was over 1000ºC. However, the SO2 adsorption in the sintering bed mainly occurred in the drying-preheating zone, adsorbed by CaCO3, Ca(OH)2, and CaO. When the SO2 adsorption reaction in the drying-preheating zone reached equilibrium, the excess SO2 gas continued to migrate to the over-wet zone and was then absorbed by Ca(OH)2 and H2O. The emission rising point of SO2 moved forward in combustion zone, and the concentration of SO2 emissions significantly increased in the case of flue gas recirculation (FGR) technique. Aiming for the reuse of the sensible heat and a reduction in exhaust gas emission, the FGR technique is proposed in the iron ore sintering process. When using the FGR technique, SO2 emission in exhaust gas gets changed. In practice, the application of the FGR technique in a sinter plant should be cooperative with the flue gas desulfurization (FGD) technique. Thus, it is necessary to study the influence of the FGR technique on SO2 emissions because it will directly influence the demand and design of the FGD system.

  4. Design considerations for wet flue gas desulfurization systems - wet scrubber hardware issues

    Energy Technology Data Exchange (ETDEWEB)

    Hurwitz, H.

    1994-12-31

    About 20 years ago the first wet flue gas desulfurization systems installed on coal fired utility boilers in the United States were experiencing extreme operating problems. In addition to their failure to achieve the necessary SO{sub 2} removal efficiencies, these FGD systems required a major investment in maintenance, both material and labor, just to remain operational. These first generation systems demonstrated that a lack of understanding of the chemistry and operating conditions of wet flue gas desulfurization can lead to diastrous results. As the air pollution control industry developed, both in the United States and in Japan, a second generation of FGD systems was introduced. These designs incorporated major improvements in both system chemistry control and in the equipment utilized in the process. Indeed, the successful introduction of utility gas desulfurization systems in Germany was possible only through the transfer of the technology improvements developed in the US and in Japan. Today, technology has evolved to a third generation of wet flue gas desulfurication systems and these systems are now offered worldwide through a series of international licensing agreements. The rapid economic growth and development in Asia and the Pacific Rim combined with existing problems in ambient air quality in these same geographic areas, has resulted in the use of advanced air pollution control systems; including flue gas desulfurization both for new utility units and for many retrofit projects. To meet the requirements of the utility industry, FGD systems must meet high standards of reliability, operability and performance. Key components in achieving these objectives are: FGD System reliability/operability/performance; FGD system supplier qualifications; process design; equipment selection. This paper will discuss each of the essential factors with a concentration on the equipment selection and wet scrubber hardware issues.

  5. Simultaneous removal of sulfur dioxide and polycyclic aromatic hydrocarbons from incineration flue gas using activated carbon fibers.

    Science.gov (United States)

    Liu, Zhen-Shu; Li, Wen-Kai; Hung, Ming-Jui

    2014-09-01

    Incineration flue gas contains polycyclic aromatic hydrocarbons (PAHs) and sulfur dioxide (SO2). The effects of SO2 concentration (0, 350, 750, and 1000 ppm), reaction temperature (160, 200, and 280 degrees C), and the type of activated carbon fibers (ACFs) on the removal of SO2 and PAHs by ACFs were examined in this study. A fluidized bed incinerator was used to simulate practical incineration flue gas. It was found that the presence of SO2 in the incineration flue gas could drastically decrease removal of PAHs because of competitive adsorption. The effect of rise in the reaction temperature from 160 to 280 degrees C on removal of PAHs was greater than that on SO2 removal at an SO2 concentration of 750 ppm. Among the three ACFs studied, ACF-B, with the highest microporous volume, highest O content, and the tightest structure, was the best adsorbent for removing SO2 and PAHs when these gases coexisted in the incineration flue gas. Implications: Simultaneous adsorption of sulfur dioxide (SO2) and polycyclic aromatic hydrocarbons (PAHs) emitted from incineration flue gas onto activated carbon fibers (ACFs) meant to devise a new technique showed that the presence of SO2 in the incineration flue gas leads to a drastic decrease in removal of PAHs because of competitive adsorption. Reaction temperature had a greater influence on PAHs removal than on SO2 removal. ACF-B, with the highest microporous volume, highest O content, and tightest structure among the three studied ACFs, was found to be the best adsorbent for removing SO2 and PAHs.

  6. Flue Gas Cleaning With Alternative Processes and Reaction Media

    DEFF Research Database (Denmark)

    Rasmussen, Søren Birk; Huang, Jun; Riisager, Anders

    2007-01-01

    Alternative methods to the traditional industrial NOX and SOXflue gas cleaning processes working at lower temperatures and/orleading to useful products are desired. In this work we presentour latest results regarding the use of molten ionic media inelectrocatalytic membrane separation, ionic liquid...... reversibleabsorption and supported ionic liquid deNOX catalysis. Furtherdevelopment of the methods will hopefully make them suitable forinstallation in different positions in the flue gas duct ascompared to the industrial methods available today....

  7. The British flue gas desulphurisation programme

    Energy Technology Data Exchange (ETDEWEB)

    Longhurst, J.W.S.

    1989-09-01

    Retrofitting UK power plants with flue gas desulfurization equipment should reduce SO{sub 2} emission by around 15%. Three systems appear suitable for UK installations: limestone/gypsum, regenerative Wellman Lord, and spray dry. The CEGB has used limestone/gypsum at Drax A B, West Burton, Fawley and Kingsnorth, and Wellman Lord at Fiddlers Ferry. Despite the environmental benefits, however, there is concern that the negative aspects of the programme (choice of technology, waste disposal, by-product disposal) may delay implementation and thus threaten Britain's aim of 30% reduction by 1999. 3 tabs.

  8. Desulfurization reaction of high sulfur content flue gas treated by electron beam

    International Nuclear Information System (INIS)

    Hirosawa, Shojiro; Suzuki, Ryoji; Aoki, Shinji; Kojima, Takuji; Hashimoto, Shoji

    2002-01-01

    Experiments of flue gas treatment by electron beam were carried out, using simulated ligniteburning flue gas containing SO 2 (5500 ppm), NO (390 ppm) and H 2 O (22%). Removal efficiency of SO 2 was more than 90% at a dose of 1-2 kGy. It shows applicability of electron beam for treatment of lignite-burning flue gas. Another removal reaction besides the radiation-induced radical reaction and the thermal reaction occurring without irradiation was suggested by the facts that removal of SO 2 by the radical reaction is only a few hundreds of ppm and the removal amounts by thermal reaction under irradiation is lower than a half of total desulfurization. The mechanism similar to thermal reaction was proposed, assuming simultaneous uptake reaction of SO 2 and NH 3 on the surface of liquid aerosol. It was suggested that ammonium nitrate having deliquescence relative humidity (DRH) of 60% at 25 deg C plays an important role in producing liquid aerosols. Decrease of DRH of ammonium nitrate with elevating temperature and with formation of double salt of ammonium sulfate results in enhancement of formation of liquid aerosols. (author)

  9. The Flakt-Hydro process: flue gas desulfurization by use of seawater

    Energy Technology Data Exchange (ETDEWEB)

    Xia, W.Z. [ABB China Limited, Shanghai (China)

    1999-07-01

    ABB's seawater scrubbing process (the Flakt-Hydro process) for flue gas desulfurization has recently triggered interest among power producers because of its simple operating principle and high reliability. The process uses seawater to absorb and neutralize sulfur dioxide in flue gases. The absorbed gas is oxidized and returned to the ocean in the form it originated in the first place, namely as dissolved sulfate salts. The process uses the seawater downstream of the power plant condensers. This paper gives an introduction to the basic principle of the process and presents some of the recent power plant applications, namely at the Paiton Private Power Project; Phase 1 (2 x 670 MWe) in Indonesia and at the Shenzhen West Power Plant, Unit 2 (300 MWe) in China.

  10. Hot Gas Particulate Cleaning Technology Applied for PFBC/IGFC -The Ceramic Tube Filter (CTF) and Metal Filter-

    Energy Technology Data Exchange (ETDEWEB)

    Sasatsu, H; Misawa, N; Kobori, K; Iritani, J

    2002-09-18

    Coal is a fossil fuel abundant and widespread all over world. It is a vital resource for energy security, because the supply is stable. However, its CO2 emission per unit calorific value is greater than that of other fossil fuels. It is necessary to develop more efficient coal utilization technologies to expand the coal utilization that meets the social demand for better environment. The Pressurized Fluidized Bed Combustion (PFBC) combined cycle has become a subject of world attention in terms of better plant operation, improved plant efficiency, lower flue gas emission and fuel flexibility. The gas turbine, one of the most important components in the PFBC, is eager for a hot gas (approximately 650-850C) cleaning system in order to eliminate the severe erosion problem with the less thermal loss. The cyclone is most popular system for a hot gas cleaning, however, the severe damage for gas turbine blades by highly concentrated fine fly ash from PFBC boiler is reported.

  11. Measurements for the determination of acid dew point and SO[sub 3] concentration in the flue gas of utility boilers

    Energy Technology Data Exchange (ETDEWEB)

    Derichs, W.; Menden, W.; Ebel, P.K. (RWE Energie AG, Bergheim (Germany))

    1991-10-01

    Until now, the well-known measuring systems for determining acid dewpoint have been applied primarily to flue gases from oil-fired combustion. Using an acid dewpoint measuring system which has now been available on the market for some time, it is possible to measure the acid dewpoint reliably and continuously in flue gas from coal-fired combustion, with low SO[sub 3] concentrations. This measuring system has also been used for flue gas from which the dust and sulphur have been removed as well as for untreated flue gas of conventional combustion systems with gas, oil, hard coal and brown coal firing and also in fluidized bed combustion systems. 6 refs., 11 figs., 2 tabs.

  12. Emission of gaseous organic pollutants and flue gas treatment technology

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Sun, Y.

    2007-01-01

    Gaseous organic pollutants are emitted into atmosphere from various sources, creating a threat to the environment and man. New, economical technologies are needed for flue gas treatment. Emission sources of pollutants are reviewed and different treatment technologies are discussed in this report. (authors)

  13. Review of technologies for mercury removal from flue gas from cement production processes

    DEFF Research Database (Denmark)

    Zheng, Yuanjing; Jensen, Anker Degn; Windelin, Christian

    2012-01-01

    sources of mercury in the cement kiln flue gas. Cement plants are quite different from power plants and waste incinerators regarding the flue gas composition, temperature, residence time, and material circulation. Cement kiln systems have some inherent ability to retain mercury in the solid materials due...... to the adsorption of mercury on the solids in the cold zone. However, recirculation of the kiln dust to the kiln will cause release of the captured mercury. The mercury chemistry in cement kiln systems is complicated and knowledge obtained from power plants and incinerators cannot be directly applied in cement...

  14. Measuring ammonia content in flue gas. Maaling af ammoniak i roeggas

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, P. R.

    1988-05-15

    As ammonia is utilized in the desulfurization of emission from power plants, there is a standing need for efficient instruments for measuring ammonia content in flue gas. Analysis is hampered by the tendency of ammonia to be adsorbed on solid surfaces when temperatures are under 350 deg. C., and to form ammonium sulfate and ammonium bisulfate when combined with sulfur oxides. A number of measuring principles and systems are described in connection with extraction systems, and the immediate removal of sulfur oxides from flue gas is recommended. At the present time (May 1988) the only efficient measuring principle seems to be infrared gas filter correlation, IR-GFC, which has been demonstrated in extraction systems, but the principle can also be used in in-situ analysis, and here the serious problem of how to keep the extraction system operating under very high temperatures is thus eliminated. High temperatures could solve the problems of adsorption and bisulfate formation in extraction systems with regard to power plants. (AB).

  15. Electron beam coal combustion flue gas treatment developments in Poland

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    1994-01-01

    The research on EB(electron beam) flue gas treatment has started in Poland since 1985. It followed early tests performed in Japan, USA and Germany. The first tests using batch method were carried out in Institute of Atomic Energy. The continuous flow laboratory installation (400 Nm 3 /h) has been constructed in the Institute of Nuclear Chemistry and Technology (INCT) then. This installation containing ILV-6 electron beam accelerator (power 20 kW, energy of electrons 0-2 MeV) is equipped with additional microwaves generator. The eb or eb/mw energy can be applied to treated flue gas. On the basis of laboratory test an industrial pilot plant has been constructed at EPS Kaweczyn near Warsaw. At this plant being the biggest of this kind (20 000 Nm 3 /h) for the first time in industrial conditions multistage irradiation has been applied (two ELW-3 accelerators 50 kW each, energy of electrons 600-800 keV). High efficiency of SO 2 and NO x simultaneous removal, usable product (fertilizer), lower (in comparison with conventional technologies - FGD/SCR) investment and operational costs are the main advantages which have led to decision about starting demonstration industrial project. Feasibility study has been prepared for EPS Pomorzany, Szczecin, Poland. The plant planned will treat flue gases from power/heat generation block (2 Benson type boilers 56 MW e plus 40 MW th each). To meet Polish limits of 1997 half of flue gases will be treated with removal efficiency of 90% for SO 2 and 70% for NO x . Total flow rate will be equal to 270 000 Nm 3 /h. (author)

  16. Study of flue gas condensing for biofuel fired heat and power plants; Studie av roekgaskondensering foer biobraensleeldade kraftvaermeanlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Axby, Fredrik; Gustafsson, J O; Nystroem, Johan; Johansson, Kent

    2000-11-01

    This report considers questions regarding flue gas condensing plants connected to bio-fuelled heat and power plants. The report consists of two parts, one where nine existing plants are described regarding technical issues and regarding the experience from the different plants. Part two is a theoretical study where heat balance calculations are made to show the technical and economical performance in different plant configurations and operating conditions. Initially the different parts in the flue gas condensing plant are described. Tube, plate and scrubber condensers are described briefly. The different types of humidifiers are also described, rotor, cross-stream plate heat exchanger and scrubber. Nine flue gas-condensing plants have been visited. The plants where chosen considering it should be bio-fuel fired plant primarily heat and power plants. Furthermore we tried to get a good dissemination considering plant configuration, supplier, geographical position, operating situation and plant size. The description of the different plants focuses on the flue gas condenser and the belonging components. The fuel, flue gas and condensate composition is described as well as which materials are used in the different parts of the plant. The experience from operating the plants and the reasons of why they decided to chose the actual condenser supplier are reported.

  17. Materials in flue gas condensation plants; Materialval vid roekgaskondensering

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmidt, Barbara; Nordling Magnus

    2003-02-01

    This project is the first part of a larger project. In the part reported here, materials for flue gas condensers have been investigated by contact with plant owners and suppliers and by a literature review of reported failures. If it is decided to continue with another part of the project, a number of materials will be long term tested on site. The project is complementary to an earlier project, which investigated the operating experiences from flue gas condensers in biomass fired cogeneration plants. In the project materials (steel and polymeric) suitable for long term testing in existing plants are discussed. It is proposed that testing in the second part of the project is made with material coupons in one plant fired with only biomass and one plant where biomass is co fired with other fuels. In the biomass fired plant a number of steel materials should be tested. In the co fired plant, with its harsher operating conditions, the same steel materials plus a number of polymeric materials should be tested. Materials suitable for testing are summarised in the report.

  18. Plasma excitation processes in flue gas simulated with Monte Carlo electron dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Tas, M.A.; Veldhuizen, E.M. van; Rutgers, W.R. [Eindhoven University of Technology (Netherlands). Div. of Electrical Energy Systems

    1997-06-07

    The excitation of gas molecules in flue gas by electron impact is calculated with a Monte Carlo (MC) algorithm for electron dynamics in partially ionized gases. The MC algorithm is straightforward for any mixture of molecules for which cross sections are available. Electron drift is simulated in the first case for homogeneous electric fields and in the second case for secondary electrons which are produced by electron-beam irradiation. The electron energy distribution function {epsilon}-bar{sub {theta}}, V-bar{sub d}, {lambda}-bar, the energy branching and the rate of excitation are calculated for standard gas mixtures of Ar-N{sub 2}, O{sub 2} and H{sub 2}O. These fundamental process parameters are needed for the study of reactions to remove NO{sub x} from flue gas. The calculated results indicate that the production of highly excited molecules in the high electric field of a streamer corona discharge has an efficiency similar to that of electron-beam irradiation. (author)

  19. The centralized control of elemental mercury emission from the flue gas by a magnetic rengenerable Fe-Ti-Mn spinel.

    Science.gov (United States)

    Liao, Yong; Xiong, Shangchao; Dang, Hao; Xiao, Xin; Yang, Shijian; Wong, Po Keung

    2015-12-15

    A magnetic Fe-Ti-Mn spinel was developed to adsorb gaseous Hg(0) in our previous study. However, it is currently extremely restricted in the control of Hg(0) emission from the flue gas for at least three reasons: sorbent recovery, sorbent regeneration and the interference of the chemical composition in the flue gas. Therefore, the effect of SO2 and H2O on the adsorption of gaseous Hg(0) on the Fe-Ti-Mn spinel and the regeneration of spent Fe-Ti-Mn spinel were investigated in this study. Meanwhile, the procedure of the centralized control of Hg(0) emission from the flue gas by the magnetic Fe-Ti-Mn spinel has been analyzed for industrial application. The spent Fe-Ti-Mn spinel can be regenerated by water washing followed by the thermal treatment at 450 °C with no obvious decrease of its ability for Hg(0) capture. Meanwhile, gaseous Hg(0) in the flue gas can be remarkably concentrated during the regeneration, facilitating its safe disposal. Initial pilot test demonstrated that gaseous Hg(0) in the real flue gas can be concentrated at least 100 times by the Fe-Ti-Mn spinel. Therefore, Fe-Ti-Mn spinel was a novel magnetic regenerable sorbent, which can be used for the centralized control of Hg(0) emission from the flue gas. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Possibilities of mercury removal in the dry flue gas cleaning lines of solid waste incineration units.

    Science.gov (United States)

    Svoboda, Karel; Hartman, Miloslav; Šyc, Michal; Pohořelý, Michael; Kameníková, Petra; Jeremiáš, Michal; Durda, Tomáš

    2016-01-15

    Dry methods of the flue gas cleaning (for HCl and SO2 removal) are useful particularly in smaller solid waste incineration units. The amount and forms of mercury emissions depend on waste (fuel) composition, content of mercury and chlorine and on the entire process of the flue gas cleaning. In the case of high HCl/total Hg molar ratio in the flue gas, the majority (usually 70-90%) of mercury is present in the form of HgCl2 and a smaller amount in the form of mercury vapors at higher temperatures. Removal of both main forms of mercury from the flue gas is dependent on chemical reactions and sorption processes at the temperatures below approx. 340 °C. Significant part of HgCl2 and a small part of elemental Hg vapors can be adsorbed on fly ash and solid particle in the air pollution control (APC) processes, which are removed in dust filters. Injection of non-impregnated active carbon (AC) or activated lignite coke particles is able to remove mainly the oxidized Hg(2+) compounds. Vapors of metallic Hg(o) are adsorbed relatively weakly. Much better chemisorption of Hg(o) together with higher sorbent capacity is achieved by AC-based sorbents impregnated with sulfur, alkali poly-sulfides, ferric chloride, etc. Inorganic sorbents with the same or similar chemical impregnation are also applicable for deeper Hg(o) removal (over 85%). SCR catalysts convert part of Hg(o) into oxidized compounds (HgO, HgCl2, etc.) contributing to more efficient Hg removal, but excess of NH3 has a negative effect. Both forms, elemental Hg(o) and HgCl2, can be converted into HgS particles by reacting with droplets/aerosol of poly-sulfides solutions/solids in flue gas. Mercury captured in the form of water insoluble HgS is more advantageous in the disposal of solid waste from APC processes. Four selected options of the dry flue gas cleaning with mercury removal are analyzed, assessed and compared (in terms of efficiency of Hg-emission reduction and costs) with wet methods and retrofits for more

  1. Comparison of Elemental Mercury Oxidation Across Vanadium and Cerium Based Catalysts in Coal Combustion Flue Gas: Catalytic Performances and Particulate Matter Effects.

    Science.gov (United States)

    Wan, Qi; Yao, Qiang; Duan, Lei; Li, Xinghua; Zhang, Lei; Hao, Jiming

    2018-03-06

    This paper discussed the field test results of mercury oxidation activities over vanadium and cerium based catalysts in both coal-fired circulating fluidized bed boiler (CFBB) and chain grate boiler (CGB) flue gases. The characterizations of the catalysts and effects of flue gas components, specifically the particulate matter (PM) species, were also discussed. The catalytic performance results indicated that both catalysts exhibited mercury oxidation preference in CGB flue gas rather than in CFBB flue gas. Flue gas component studies before and after dust removal equipment implied that the mercury oxidation was well related to PM, together with gaseous components such as NO, SO 2 , and NH 3 . Further investigations demonstrated a negative PM concentration-induced effect on the mercury oxidation activity in the flue gases before the dust removal, which was attributed to the surface coverage by the large amount of PM. In addition, the PM concentrations in the flue gases after the dust removal failed in determining the mercury oxidation efficiency, wherein the presence of different chemical species in PM, such as elemental carbon (EC), organic carbon (OC) and alkali (earth) metals (Na, Mg, K, and Ca) in the flue gases dominated the catalytic oxidation of mercury.

  2. EB technology for the purification of flue gases

    International Nuclear Information System (INIS)

    Kojima, Takuji

    2003-01-01

    Sulfur oxides and nitrogen oxides in flue gas from coal-combustion boilers in power plants, dioxins in flue gas from municipal waste incineration facilities and toxic volatile organic compounds (VOCs) in off-gas from painting or cleaning factories are among air pollutants for which emission is regulated by a law in Japan. Electron beam is the effective and easy controllable radiation source for treatment of these flue gases. This report describes outline of the results so far obtained at JAERI on electron beam treatment of flue gas. The removal performance higher than 90% at 10 kGy for flue gas containing 800 ppm SOx and 225 ppm NOx were achieved and being applied to real-scale power plants in Poland and China with expectation of cost reduction of 20% compared to conventional plants. Decomposition of dioxins in flue gas from solid waste incinerators is another project. Using an accelerator of 300 keV and 40 mA for treatment of real incineration gas at 200degC, we obtain 90% decomposition of dioxins at 15 kGy irradiation. Expansion of these flue gas purification technologies combined with low-energy electron accelerators is expected. (S. Ohno)

  3. Electron beam flue gas treatment. Research cooperation among JAERI, IAEA and INCT

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    The research co-operation is conducted among Japan Atomic Energy Research Institute (JAERI), International Atomic Energy Agency (IAEA) and Institute of Nuclear Chemistry and Technology in Poland (INCT) on Electron Beam Flue Gas Treatment from January 1993 to March 1997. The first phase of the cooperation was carried out for 3 years from January 1993 to March 1995. This cooperation was performed through information exchange meetings (Coordination Meetings), held in Takasaki and Warsaw, and experiments and discussions by exchange scientists. Many useful results were obtained on electron beam treatment of flue gas from coal-combustion heat generation plant in Kaweczyn within the frame work of the research co-operation. This report includes the main results of the tripartite research cooperation. (author)

  4. Analysis of CO2 Separation from Flue Gas, Pipeline Transportation, and Sequestration in Coal

    Energy Technology Data Exchange (ETDEWEB)

    Eric P. Robertson

    2007-09-01

    This report was written to satisfy a milestone of the Enhanced Coal Bed Methane Recovery and CO2 Sequestration task of the Big Sky Carbon Sequestration project. The report begins to assess the costs associated with separating the CO2 from flue gas and then injecting it into an unminable coal seam. The technical challenges and costs associated with CO2 separation from flue gas and transportation of the separated CO2 from the point source to an appropriate sequestration target was analyzed. The report includes the selection of a specific coal-fired power plant for the application of CO2 separation technology. An appropriate CO2 separation technology was identified from existing commercial technologies. The report also includes a process design for the chosen technology tailored to the selected power plant that used to obtain accurate costs of separating the CO2 from the flue gas. In addition, an analysis of the costs for compression and transportation of the CO2 from the point-source to an appropriate coal bed sequestration site was included in the report.

  5. Biomimetic Membrane for CO2 Capture from Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Michael C. Trachtenberg

    2007-05-31

    These Phase III experiments successfully addressed several issues needed to characterize a permeator system for application to a pulverized coal (PC) burning furnace/boiler assuming typical post-combustion cleanup devices in place. We completed key laboratory stage optimization and modeling efforts needed to move towards larger scale testing. The SOPO addressed six areas. Task 1--Post-Combustion Particle Cleanup--The first object was to determine if the Carbozyme permeator performance was likely to be reduced by particles (materials) in the flue gas stream that would either obstruct the mouth of the hollow fibers (HF) or stick to the HF bore wall surface. The second, based on the Acceptance Standards (see below), was to determine whether it would be preferable to clean the inlet gas stream (removing acid gases and particulates) or to develop methods to clean the Carbozyme permeator if performance declined due to HF block. We concluded that condensation of particle and particulate emissions, in the heat exchanger, could result in the formation of very sticky sulfate aerosols with a strong likelihood of obtruding the HF. These must be managed carefully and minimized to near-zero status before entering the permeator inlet stream. More extensive post-combustion cleanup is expected to be a necessary expense, independent of CO{sub 2} capture technology This finding is in agreement with views now emerging in the literature for a variety of CO{sub 2} capture methods. Task 2--Water Condensation--The key goal was to monitor and control temperature distributions within the permeator and between the permeator and its surroundings to determine whether water condensation in the pores or the HF bore would block flow, decreasing performance. A heat transfer fluid and delivery system were developed and employed. The result was near isothermal performance that avoided all instances of flow block. Direct thermocouple measurements provided the basis for developing a heat transfer

  6. Hot Gas Halos in Galaxies

    Science.gov (United States)

    Mulchaey, John

    Most galaxy formation models predict that massive low-redshift disk galaxies are embedded in extended hot halos of externally accreted gas. Such gas appears necessary to maintain ongoing star formation in isolated spirals like the Milky Way. To explain the large population of red galaxies in rich groups and clusters, most galaxy evolution models assume that these hot gas halos are stripped completely when a galaxy enters a denser environment. This simple model has been remarkably successful at reproducing many observed properties of galaxies. Although theoretical arguments suggest hot gas halos are an important component in galaxies, we know very little about this gas from an observational standpoint. In fact, previous observations have failed to detect soft X-ray emission from such halos in disk galaxies. Furthermore, the assumption that hot gas halos are stripped completely when a galaxy enters a group or cluster has not been verified. We propose to combine proprietary and archival XMM-Newton observations of galaxies in the field, groups and clusters to study how hot gas halos are impacted by environment. Our proposed program has three components: 1) The deepest search to date for a hot gas halo in a quiescent spiral galaxy. A detection will confirm a basic tenet of disk galaxy formation models, whereas a non-detection will seriously challenge these models and impose new constraints on the growth mode and feedback history of disk galaxies. 2) A detailed study of the hot gas halos properties of field early-type galaxies. As environmental processes such as stripping are not expected to be important in the field, a study of hot gas halos in this environment will allow us to better understand how feedback and other internal processes impact hot gas halos. 3) A study of hot gas halos in the outskirts of groups and clusters. By comparing observations with our suite of simulations we can begin to understand what role the stripping of hot gas halos plays in galaxy

  7. Preheating of manure utilizing heat exchanger and flue gas. Forvarmning af gylle ved varmeveksling med roeggas

    Energy Technology Data Exchange (ETDEWEB)

    Weber, J.

    1987-07-15

    It has been shown that preheating of manures in biomass conversion plants to a temperature of 50-60 deg. C, before the anaerobic digestion takes place at a temperature of 35-45 deg. C, results in an increase of methane production. But the method normally involves an increase in energy consumption. The aim of the project was to develope methods of utilizing heat from flue gas emitted from the boiler connected to the plant, with the help of a heat exchanger. The heat thus recovered would be used to preheat the manure. The chosen method was to inject the flue gas directly into the manure mass, following this up with heat exchanging and condensing. In order to mix the flue gas thoroughly into the manure an ejector was used, this was driven by the manure flow. Results were satisfactory. (AB).

  8. STUDY OF THE EFFECT OF CHLORINE ADDITION ON MERCURY OXIDATION BY SCR CATALYST UNDER SIMULATED SUBBITUMINOUS COAL FLUE GAS

    Science.gov (United States)

    An entrained flow reactor is used to study the effect of addition of chlorine-containing species on the oxidation of elemental mercury (Hgo)by a selective catalytic reduction (SCR) catalyst in simulated subbituminous coal combustion flue gas. The combustion flue gas was doped wit...

  9. Wettability determination by contact angle measurements: hvbB coal-water system with injection of synthetic flue gas and CO2.

    Science.gov (United States)

    Shojai Kaveh, Narjes; Rudolph, E Susanne J; Wolf, Karl-Heinz A A; Ashrafizadeh, Seyed Nezameddin

    2011-12-01

    Geological sequestration of pure carbon dioxide (CO(2)) in coal is one of the methods to sequester CO(2). In addition, injection of CO(2) or flue gas into coal enhances coal bed methane production (ECBM). The success of this combined process depends strongly on the wetting behavior of the coal, which is function of coal rank, ash content, heterogeneity of the coal surface, pressure, temperature and composition of the gas. The wetting behavior can be evaluated from the contact angle of a gas bubble, CO(2) or flue gas, on a coal surface. In this study, contact angles of a synthetic flue gas, i.e. a 80/20 (mol%) N(2)/CO(2) mixture, and pure CO(2) on a Warndt Luisenthal (WL) coal have been determined using a modified pendant drop cell in a pressure range from atmospheric to 16 MPa and a constant temperature of 318 K. It was found that the contact angles of flue gas on WL coal were generally smaller than those of CO(2). The contact angle of CO(2) changes from water-wet to gas-wet by increasing pressure above 8.5 MPa while the one for the flue gas changes from water-wet to intermediate-wet by increasing pressure above 10 MPa. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Coal fired flue gas mercury emission controls

    CERN Document Server

    Wu, Jiang; Pan, Weiguo; Pan, Weiping

    2015-01-01

    Mercury (Hg) is one of the most toxic heavy metals, harmful to both the environment and human health. Hg is released into the atmosphere from natural and anthropogenic sources and its emission control has caused much concern. This book introduces readers to Hg pollution from natural and anthropogenic sources and systematically describes coal-fired flue gas mercury emission control in industry, especially from coal-fired power stations. Mercury emission control theory and experimental research are demonstrated, including how elemental mercury is oxidized into oxidized mercury and the effect of

  11. Furnace draft dynamics analysis after a flue gas desulphurization system incorporation

    Energy Technology Data Exchange (ETDEWEB)

    Zazo, J.F.L. [Tecnatom, S.A. (Spain)

    2007-07-01

    Due to environmental regulations some utilities are modifying coal-fired power groups by installing a flue gas desulfurisation system (FGDS) in order to remove SO{sub 2} from a gas stream. These studies have been ordered by 'Endesa Generacion' for the following power plant groups: C.T. Teruel Grs. 1-3, C.T. Litoral Gr. 2, C.T. Compostilla Gr. 3, C.T. Alucdia Grs. 1-2, C.T. Compostilla Grs. 4-5 (on-going); and C.T. Los Barrios (on-going). The pictures that appear in this abstract correspond to Compostilla Gr.4 and Los Barrios projects. In both cases FGDS installation implies a new booster fan and heat exchanger keeping former Induced Draft Fans (IDFs). The main goal for these projects is to analyze the new flue-gas dynamic, in order to: detect risk situations to equipment, particularly to boiler integrity, test control system strategies and interlocks, select parameters to valves and control system to minimize pressure transients, and test operation strategies. 14 figs.

  12. Numerical simulation of flue gas purification from NOx, SO2 by electron beam

    International Nuclear Information System (INIS)

    Morgunov, V.V.; Shkilko, A.M.; Fainchtein, O.L.

    2011-01-01

    Complete text of publication follows. The paper is devoted to numerical simulation of radiation-chemical processes in gas phase, which are take place during electron beam (EB) treatments of flue gases. A mathematical model of EB processes in gas phase was created. Also, a computer code which numerically simulates radiation-chemical processes during EB treatment of flue gases was created. The needed data such as chemical species, radiation-chemical yields and rate constants of the chemical reactions were collected and putted into database. The computer code allows do following: 1. The following technological parameters: irradiation dose, temperature, initial composition of the flue gases, time of irradiation (time which flue gases spend in an irradiation zone), one- or two-stage irradiation can be defined by the user in the code shell; 2. In accordance with the initial composition of flue gases selects chemical species from database of the chemical species (total amount of species in database is 522) which took part in simulation taking into account species that are formed due to irradiation; 3. In accordance with the selected chemical species selects chemical and radiation-chemical reactions from the database of reactions (total amount of chemical and radiation-chemical reaction is 2275) which are took part in the simulation; 4. Creates a stiff system of ordinary differential equations (ODEs) which describes chemical and radiation-chemical reactions; 5. Solves the received system of ODEs by backward differentiation formula (Gear's method); 6. Creates plots of dependencies: concentrations of chemical species versus time of irradiation under different parameters of modeled EB-processes. The received results. For the following technological parameters: irradiation dose is 8.0 kGy; two stage irradiation; initial temperature is 353 deg K; time of the irradiation - 4 s; initial composition of the flue gases - typical for power plant, following removal efficiencies were

  13. SNCR method of flue gas denitrification

    Energy Technology Data Exchange (ETDEWEB)

    Kuropka, J. [Politechniki Wroclawskiej, Wroclaw (Poland). Instytut Inzynierii Ochrony Srodowiska

    1998-12-31

    Current achievements in experiments on selective non-catalytic reduction of nitrogen oxides from flue gases were presented. Some basic parameters of denitrification process (temperature of reaction, contact time, molar ratio of agents, additions to reacting substances) which influence the rate of nitrogen oxides emission from flue gases were analysed. On the basis of conducted experiments with calcium hydroxide and urea or calcium carbonate and urea on full-scale FGD installation on WP-120 boiler it was found that SNCR method can be applied to simultaneous denitrification and desulfurisation of flue gases. 27 refs., 10 figs.

  14. Carbon Mineralization by Aqueous Precipitation for Beneficial Use of CO2 from Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Devenney, Martin; Gilliam, Ryan; Seeker, Randy

    2014-06-01

    The objective of this project is to demonstrate an innovative process to mineralize CO2 from flue gas directly to reactive carbonates and maximize the value and versatility of its beneficial use products. The program scope includes the design, construction, and testing of a CO2 Conversion to Material Products (CCMP) Pilot Demonstration Plant utilizing CO2 from the flue gas of a power production facility in Moss Landing, CA as well as flue gas from coal combustion. This topical report covers Phase 2b, which is the construction phase of pilot demonstration subsystems that make up the integrated plant. The subsystems included are the mineralization subsystem, the Alkalinity Based on Low Energy (ABLE) subsystem, the waste calcium oxide processing subsystem, and the fiber cement board production subsystem. The fully integrated plant is now capable of capturing CO2 from various sources (gas and coal) and mineralizing into a reactive calcium carbonate binder and subsequently producing commercial size (4ftx8ft) fiber cement boards. The topical report provides a description of the “as built” design of these subsystems and the results of the commissioning activities that have taken place to confirm operability. At the end of Phase 2b, the CCMP pilot demonstration is fully ready for testing.

  15. Criteria for selecting a flue gas purification system for waste incineration plants

    Energy Technology Data Exchange (ETDEWEB)

    Mosch, H

    1985-12-01

    This paper evaluates the available systems with a view to three basic principles of gaseous effluent removal, relating to dust, SO/sub 2/, HCl and HF, by discussing criteria such as performance with regard to environmental hygiene, performance with regard to material or energy consumption, terms and conditions, operational conditions, and economics. The three methods discussed are: (1) Scrubbing and effluent treatment including evaporation and flue gas reheating or other means of treating the flue gas cooled down to about 65/sup 0/C. (2) Spray sorption by means of flash drying reactors, similar to the spray drying method. (3) Blow-in sorption, as the method may be called. The dry, powdered reagent, in general slack lime with at least 90 p.c. of Ca(OH)/sub 2/, is blown into the reactors. (orig./HP).

  16. Possibility study of gasifier with axial circulating flue gas for reducing Tar

    Science.gov (United States)

    Poowadin, T.; Polsongkram, M.; Khantikomol, P.

    2018-01-01

    This present research article aims to study the possibility of gasification by axial core flue gas circulating kiln and find the efficiency of syngas production. An axial core flue gas circulating tube was installed in the center of the updraft gasifier in purposing of tar reducing. In the present study, the eucalyptus wood chip 4, 8, and 10 kg with the moisture content 16% were examined. Several type-K thermocouples were employed to measure the temperatures at preheat, combustion, reduction, pyrolysis, drying, and gas outlet zone. The results showed that the temperatures in the combustion and the reduction zone of the kiln with the axial core flue gas recirculating were lower than the kiln without the core owing to installing the core would reduce the combustion zone area in biomass burning. Obviously, the temperature in the pyrolysis and drying zone were nearly the same as both with and without the core. In consideration of syngas components, it was found that CO production from the gasifier with the core was higher than the gasifier without the core about 25%. Other gases, however, were almost same. The syngas production efficiency obtained from the gasifier with the core decreased with increasing the mass of biomass. It showed that the highest efficiency was 30% at 4 kg supplying biomass. In comparison, the efficiencies of both the kilns with and without the core were not different. For liquid product, the amount of liquid decreased about 47.23% comparing with the gasifier without the core.

  17. Near-Zero Emissions Oxy-Combustion Flue Gas Purification Task 2: SOx/Nox/Hg Removal for High Sulfur Coal

    Energy Technology Data Exchange (ETDEWEB)

    Nick Degenstein; Minish Shah; Doughlas Louie

    2012-05-01

    The goal of this project is to develop a near-zero emissions flue gas purification technology for existing PC (pulverized coal) power plants that are retrofitted with oxy-combustion technology. The objective of Task 2 of this project was to evaluate an alternative method of SOx, NOx and Hg removal from flue gas produced by burning high sulfur coal in oxy-combustion power plants. The goal of the program was not only to investigate a new method of flue gas purification but also to produce useful acid byproduct streams as an alternative to using a traditional FGD and SCR for flue gas processing. During the project two main constraints were identified that limit the ability of the process to achieve project goals. 1) Due to boiler island corrosion issues >60% of the sulfur must be removed in the boiler island with the use of an FGD. 2) A suitable method could not be found to remove NOx from the concentrated sulfuric acid product, which limits sale-ability of the acid, as well as the NOx removal efficiency of the process. Given the complexity and safety issues inherent in the cycle it is concluded that the acid product would not be directly saleable and, in this case, other flue gas purification schemes are better suited for SOx/NOx/Hg control when burning high sulfur coal, e.g. this project's Task 3 process or a traditional FGD and SCR.

  18. Method of flash evaporation and condensation – heat pump for deep cooling of coal-fired power plant flue gas: Latent heat and water recovery

    International Nuclear Information System (INIS)

    Li, Yuzhong; Yan, Min; Zhang, Liqiang; Chen, Guifang; Cui, Lin; Song, Zhanlong; Chang, Jingcai; Ma, Chunyuan

    2016-01-01

    Highlights: • A method is developed for deep cooling of flue gas in coal-fired boilers. • The method can recover both latent heat and water from flue gas. • The method utilizes FGD scrubber as a deep cooling exchanger. • The method adopts the direct heat exchange mode to avoid the corrosion problem. - Abstract: Flue gas waste heat recovery and utilization is an efficient means to improve the energy efficiency of coal-fired power plants. At present, the surface corrosion and fouling problems of heat exchanger hinder the development of flue gas deep cooling. In this study, a novel flue gas deep cooling method that can reduce flue gas temperature below the dew point of vapor to recover latent heat and obtain clean water simultaneously is proposed to achieve improved energy efficiency. The heat transfer mode of this method is the direct contact mode, which takes the scrubber, e.g. the flue gas desulfurization (FGD) scrubber, as the deep cooling exchanger. The flash evaporation and condensation (FEC) device and heat pump (HP) are utilized to provide low-temperature medium, such as FGD slurry or water, for washing and deep cooling flue gas, to collect recovered water, and to absorb recovered waste heat. This method is called as the FEC–HP method. This paper elaborated on two optional models of the proposed method. The mechanism for recovering heat and water was also analyzed using the customized flue gas humidity chart, and the method to quantitate recovered heat and water, as well as the results of the case of a 300 MW coal-fired generator set were provided. Net present value calculations showed that this method is profitable in the scenario of burning high-water-content coals. Several potential advantages of this method and suggestions for practical application were also discussed.

  19. Dew point of flue gas in the combustion of brown coal briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Schinkel, W

    1977-08-01

    Economical operation of small steam generators can follow two courses, viz. to channel the emitted gases through the plant and reduce waste gas loss. Two possibilities exist to achieve this: firstly a steam generating process with only slight excess air; secondly a reduction of the emitted gas temperature. The lowest waste gas temperature found in sulphur-containing combustion materials is measured by finding the acid dew-point of the waste gas. The following results in the case of brown coal briquettes were found. Measurements of the dew point of flue gas in two steam generators, both of the double flue type, one having a capacity of 12.5 t/h, the other 25 t/h, one using brown coal briquettes with 1% sulphur content, the other with 3%, resulted in the fact that the dew point can be measured. It was shown that a low air ratio leads to a lowering of the dew point. However this process is unfortunately economically unviable in chain grate generators as the waste gas becomes so thin under a high air ratio that the dew point can only be minimally reduced. Further the acid dew point is only slightly influenced by partial operation of the generator and the infusion of briquette residue.

  20. Advanced separation technology for flue gas cleanup. Final report, February 1998

    Energy Technology Data Exchange (ETDEWEB)

    Bhown, A.S.; Alvarado, D.; Pakala, N.; Tagg, T.; Riggs, T.; Ventura, S.; Sirkar, K.K.; Majumdar, S.; Bhaumick, D.

    1998-06-01

    The objective of this work by SRI International was to develop a novel system for regenerable SO{sub 2} and NO{sub x} scrubbing of flue gas that focuses on (1) a novel method for regenerating spent SO{sub 2} scrubbing liquor and (2) novel chemistry for reversible absorption of NO{sub x}. High efficiency, hollow fiber contactors (HFCs) were proposed as the devices for scrubbing the SO{sub 2} and NO{sub x} from the flue gas. The system would be designed to remove more than 95% of the SO{sub 2} and more than 75% of the NO{sub x} from flue gases typical of pulverized coal-fired power plants at a cost that is at least 20% less than combined wet limestone scrubbing of SO{sub x} and selective catalytic reduction of NO{sub x}. In addition, the process would generate only marketable by-products, if any (no waste streams are anticipated). The major cost item in existing technology is capital investment. Therefore, the approach was to reduce the capital cost by using high-efficiency, hollow fiber devices for absorbing and desorbing the SO{sub 2} and NO{sub x}. The authors also introduced new process chemistry to minimize traditionally well-known problems with SO{sub 2} and NO{sub x} absorption and desorption. The process and progress in its development are described.

  1. Mechanical, Hygric and Thermal Properties of Flue Gas Desulfurization Gypsum

    Directory of Open Access Journals (Sweden)

    P. Tesárek

    2004-01-01

    Full Text Available The reference measurements of basic mechanical, thermal and hygric parameters of hardened flue gas desulfurization gypsum are carried out. Moisture diffusivity, water vapor diffusion coefficient, thermal conductivity, volumetric heat capacity and linear thermal expansion coefficient are determined with the primary aim of comparison with data obtained for various types of modified gypsum in the future. 

  2. Microalgal biomass production and on-site bioremediation of carbon dioxide, nitrogen oxide and sulfur dioxide from flue gas using Chlorella sp. cultures.

    Science.gov (United States)

    Chiu, Sheng-Yi; Kao, Chien-Ya; Huang, Tzu-Ting; Lin, Chia-Jung; Ong, Seow-Chin; Chen, Chun-Da; Chang, Jo-Shu; Lin, Chih-Sheng

    2011-10-01

    The growth and on-site bioremediation potential of an isolated thermal- and CO₂-tolerant mutant strain, Chlorella sp. MTF-7, were investigated. The Chlorella sp. MTF-7 cultures were directly aerated with the flue gas generated from coke oven of a steel plant. The biomass concentration, growth rate and lipid content of Chlorella sp. MTF-7 cultured in an outdoor 50-L photobioreactor for 6 days was 2.87 g L⁻¹ (with an initial culture biomass concentration of 0.75 g L⁻¹), 0.52 g L⁻¹ d⁻¹ and 25.2%, respectively. By the operation with intermittent flue gas aeration in a double-set photobioreactor system, average efficiency of CO₂ removal from the flue gas could reach to 60%, and NO and SO₂ removal efficiency was maintained at approximately 70% and 50%, respectively. Our results demonstrate that flue gas from coke oven could be directly introduced into Chlorella sp. MTF-7 cultures to potentially produce algal biomass and efficiently capture CO₂, NO and SO₂ from flue gas. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Application of Module System for Processing a Large Capacity of Coal Steam Power Plant Flue gas by Electron Beam Machine

    International Nuclear Information System (INIS)

    Rukijatmo; Munawir Z, M.

    2003-01-01

    Conceptual design of SOx dan NOx flue gas treatment base on 25% of 400 M We capacity and 90% efficiency reduction of SOx, the electron beam machine will be utilized to performed the environment quality standard of air pollution. The technical specification of electron beam machine, processing system and chamber dimension should conformed to the regulation. The discussion is focused on the selection of electron beam machine type and the dimension of radiation vessel for perfect reaction and exact time processing. The design calculation is indicated that we need two electron beam machines of 500 mA, 800 kV installed in parallel and 3 up to 3.4 metres diameter, the speed of flue gas in the vessel around 16.4 up to 18.14 metre per second, 80% treatment of 0,7% sulphur content coal is conform to regulation on emission of flue gas environment, and only 50% of flue gas needed to be treated by 4 modular. (author)

  4. Semi-dry flue gas desulfurization using Ca(OH)2 in a fluidized bed reactor with bed materials

    International Nuclear Information System (INIS)

    Park, Young Oak; Roh, Hak Jae; Oh, Chang Sup; Kim, Yong Ha

    2010-01-01

    The main objective of present work is to reduce sulfur dioxide emission from power plant for the environment protection. The fluidized bed (FB) was used as the reactor with bed materials in a new semi-dry flue gas desulfurization (FGD) process to achieve high desulfurization efficiency (>98%). Fine powder of Ca(OH) 2 as sorbent and water were continuously fed separately to the bed reactor where bed materials (2 mm glass beads) were fluidized vigorously with flue gas (flow 720 Nm 3 / hr) using bench scale plant of stainless steel column. We have investigated different effects of water injection flow rate, Ca/ S molar ratio and weight of bed materials on SO 2 removal. The increments in the Ca/ S molar ratio and water injection flow rate have been resulted higher desulfurization efficiency with certain disadvantages such as higher sorbent cost and lower temperature of the treated flue gas, respectively. (author)

  5. Numerical Study Of Flue Gas Flow In A Multi Cyclone Separator

    OpenAIRE

    Ganga Reddy C; Umesh Kuppuraj

    2015-01-01

    The removal of harmful particulate matter from power plant flue gas is of critical importance to the environment and its inhabitants. The present work illustrates the use of multi-cyclone separators to remove the particulate matter from the bulk of the gas exhausted to the atmosphere. The method has potential to replace conventional systems like electrostatic precipitator due to inherent low power requirement and low maintenance. A parametric model may be employed to design the sy...

  6. Flue gas conditioning for improved particle collection in electrostatic precipitators. Quarterly technical report

    Energy Technology Data Exchange (ETDEWEB)

    Durham, M.D.

    1992-04-27

    The purpose of this research program is to identify and evaluate a variety of additives capable of increasing particle cohesion which could be used for improving collection efficiency in an ESP. A three-phase screening process will be used to provide the, evaluation of many additives in a logical and cost-effective manner. The three step approach involves the following experimental setups: 1. Provide a preliminary screening in the laboratory by measuring the effects of various conditioning agents on reentrainment of flyash particles in an electric field operating at simulated flue gas conditions. 2. Evaluate the successful additives using a 100 acfm bench-scale ESP operating on actual flue gas. 3. Obtain the data required for scaling up the technology by testing the two or three most promising conditioning agents at the pilot scale.

  7. CO2 Capture from Flue Gas using Amino Acid Salt Solutions

    DEFF Research Database (Denmark)

    Lerche, Benedicte Mai; Stenby, Erling Halfdan; Thomsen, Kaj

    2009-01-01

    difficult. Amino acid salt solutions have emerged as an alternative to the alkanolamine solutions. A number of advantages make amino acid salt solutions attractive solvents for CO2 capture from flue gas. In the present study CO2 absorption in aqueous solutions of 0.5 M potassium glycinate and 0.5 M...

  8. Carbon Mineralization by Aqueous Precipitation for Beneficial Use of CO2 from Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Devenney, Martin [Calera Corporation, Moss Landing, CA (United States); Gilliam, Ryan [Calera Corporation, Moss Landing, CA (United States); Seeker, Randy [Calera Corporation, Moss Landing, CA (United States)

    2015-06-30

    The objective of this project was to demonstrate an innovative process to mineralize CO2 from flue gas directly to reactive carbonates and maximize the value and versatility of its beneficial use products. The program scope includes the design, construction, and testing of a CO2 Conversion to Material Products (CCMP) Pilot Demonstration Plant utilizing CO2 from the flue gas of a power production facility in Moss Landing, CA as well as flue gas from coal combustion. This final report details all development, analysis, design and testing of the project. Also included in the final report are an updated Techno-Economic Analysis and CO2 Lifecycle Analysis. The subsystems included in the pilot demonstration plant are the mineralization subsystem, the Alkalinity Based on Low Energy (ABLE) subsystem, the waste calcium oxide processing subsystem, and the fiber cement board production subsystem. The fully integrated plant was proven to be capable of capturing CO2 from various sources (gas and coal) and mineralizing it into a reactive calcium carbonate binder and subsequently producing commercial size (4ftx8ft) fiber cement boards. The final report provides a description of the “as built” design of these subsystems and the results of the commissioning activities that have taken place to confirm operability. The report also discusses the results of the fully integrated operation of the facility. Fiber cement boards have been produced in this facility exclusively using reactive calcium carbonate from captured CO2 from flue gas. These boards meet all US and China appropriate acceptance standards. Use demonstrations for these boards are now underway.

  9. Carbon Dioxide Removal from Flue Gas Using Microporous Metal Organic Frameworks

    Energy Technology Data Exchange (ETDEWEB)

    Lesch, David A

    2010-06-30

    UOP LLC, a Honeywell Company, in collaboration with Professor Douglas LeVan at Vanderbilt University (VU), Professor Adam Matzger at the University of Michigan (UM), Professor Randall Snurr at Northwestern University (NU), and Professor Stefano Brandani at the University of Edinburgh (UE), supported by Honeywell's Specialty Materials business unit and the Electric Power Research Institute (EPRI), have completed a three-year project to develop novel microporous metal organic frameworks (MOFs) and an associated vacuum-pressure swing adsorption (vPSA) process for the removal of CO{sub 2} from coal-fired power plant flue gas. The project leveraged the team's complementary capabilities: UOP's experience in materials development and manufacturing, adsorption process design and process commercialization; LeVan and Brandani's expertise in high-quality adsorption measurements; Matzger's experience in syntheis of MOFs and the organic components associated with MOFs; Snurr's expertise in molecular and other modeling; Honeywell's expertise in the manufacture of organic chemicals; and, EPRI's knowledge of power-generation technology and markets. The project was successful in that a selective CO{sub 2} adsorbent with good thermal stability and reasonable contaminant tolerance was discovered, and a low cost process for flue gas CO{sub 2} capture process ready to be evaluated further at the pilot scale was proposed. The team made significant progress toward the current DOE post-combustion research targets, as defined in a recent FOA issued by NETL: 90% CO{sub 2} removal with no more than a 35% increase in COE. The team discovered that favorable CO{sub 2} adsorption at more realistic flue gas conditions is dominated by one particular MOF structure type, M/DOBDC, where M designates Zn, Co, Ni, or Mg and DOBDC refers to the form of the organic linker in the resultant MOF structure, dioxybenzenedicarboxylate. The structure of the M/DOBDC MOFs

  10. Pilot-plant for NOx, SO2, HCl removal from flue-gas of municipal waste incinerator by electron beam irradiation

    International Nuclear Information System (INIS)

    Doi, Takeshi; Suda, Shoichi; Morishige, Atsushi; Tokunaga, Okihiro; Aoki, Yasushi; Sato, Shoichi; Komiya, Mikihisa; Hashimoto, Nobuo; Nakajima, Michihiro.

    1992-01-01

    A pilot-Plant for NO x , SO 2 and HCl removal from flue-gas of municipal waste incinerator by electron beam irradiation was designed and its construction at Matsudo City Waste Disposal Center was planned. The flue-gas of 1,000 Nm 3 /hr is guided from the waste incinerator flue-gas line of 30,000 Nm 3 /hr to the Pilot-Plant to be processed by spraying Ca(OH) 2 slurry (NKK-LIMAR Process) and irradiating high-energy electron beam of an accelerator. NO x , SO 2 and HCl are removed simultaneously from the flue-gas by the enhanced reaction with Ca(OH) 2 under irradiation. According to the basic research performed using a small size reactor at TRCRE of JAERI, the electron beam irradiation process was proved to be very effective for these harmful gases removal. Based on this result, the Pilot-Plant was designed for the demonstration of NO x , SO 2 and HCl removal performance using electron accelerator of maximum energy 0.95 MeV and maximum power 15 kW. The designing and planning were promoted by NKK in cooperation with JAERI and Matsudo City. (author)

  11. ENHANCED CONTROL OF MERCURY BY WET FLUE GAS DESULFURIZATION SYSTEMS; FINAL

    International Nuclear Information System (INIS)

    Unknown

    2001-01-01

    The U.S. Department of Energy and EPRI co-funded this project to improve the control of mercury emissions from coal-fired power plants equipped with wet flue gas desulfurization (FGD) systems. The project has investigated catalytic oxidation of vapor-phase elemental mercury to a form that is more effectively captured in wet FGD systems. If successfully developed, the process could be applicable to over 90,000 MW of utility generating capacity with existing FGD systems, and to future FGD installations. Field tests were conducted to determine whether candidate catalyst materials remain active towards mercury oxidation after extended flue gas exposure. Catalyst life will have a large impact on the cost effectiveness of this potential process. A mobile catalyst test unit was used to test the activity of four different catalyst materials for a period of up to six months each at three utility sites. Catalyst testing was completed at the first site, which fires Texas lignite, in December 1998; at the second test site, which fires a Powder River Basin subbituminous coal, in November 1999; and at the third site, which fires a medium- to high-sulfur bituminous coal, in January 2001. Results of testing at each of the three sites were reported in previous technical notes. At Site 1, catalysts were tested only as powders dispersed in sand bed reactors. At Sites 2 and 3, catalysts were tested in two forms, including powders dispersed in sand and in commercially available forms such as extruded pellets and coated honeycomb structures. This final report summarizes and presents results from all three sites, for the various catalyst forms tested. Field testing was supported by laboratory tests to screen catalysts for activity at specific flue gas compositions, to investigate catalyst deactivation mechanisms and methods for regenerating spent catalysts. Laboratory results are also summarized and discussed in this report

  12. The Ispra flue gas desulphurization process: research, development and marketing aspects

    Energy Technology Data Exchange (ETDEWEB)

    Velzen, D. van (JRC, Ispra (Italy))

    1993-01-01

    The most widely used method of reducing sulphur dioxide emission is flue gas desulphurisation (FGD). The combustion gases produced by large combustion units (for example power stations) are in contact with a liquid or a slurry containing a reactant for SO[sub 2]. This operation produces a waste gas which is essentially free of sulphur dioxide. This paper describes the steps involved in the research and development of the new Ispra FGD process. Details of market consideration are also given.

  13. Distribution of heavy metals from flue gas in algal bioreactor

    Science.gov (United States)

    Napan, Katerine

    Flue gas from coal-fired power plants is a major source of CO2 to the atmosphere. Microalgae can use this enriched form of CO2 as carbon source and in turn the biomass can be used to produce food, feed, fertilizer and biofuels. However, along with CO2, coal-based flue gas will inevitably introduce heavy metals, which have a high affinity to bind algal cells, could be toxic to the organisms and if transferred to the products could limit their uses. This study seeks to address the distribution and impact of heavy metals present in flue gas on microalgae production systems. To comprehend its effects, algae Scenedesmus obliquus was grown in batch reactors in a multimetal system. Ten heavy metals (Cu, Co, Zn, Pb, As, Se, Cr, Hg, Ni and Cd) were selected and were evaluated at four concentrations (1X, 2X, 5X and 10X). Results show that most heavy metals accumulated mainly in biomass and were found in very low concentrations in media. Hg was shown to be lost from the culture, with low amounts present in the biomass. An upper limit for As uptake was observed, suggesting its likelihood to build-up in the system during medium recycle. The As limited bioaccumulation was overcome by addition of sulfur to the algal medium. Heavy metal at 2X, 5X and 10X inhibited both growth and lipid production, while at the reference concentration both biomass and lipids yields were increased. Heavy metal concentrations in the medium and biomass were time dependent, and at the end of the cultivation most heavy metals in the supernatant solution complied with the recommendations for irrigation water, while biomass was below limits for cattle and poultry feed, fertilizer, plastic and paper. This research shows that bioremediation of CO2 and heavy metals in combination with energy production can be integrated, which is an environmentally friendly form of biotechnology.

  14. Estimation of combustion flue gas acid dew point during heat recovery and efficiency gain

    Energy Technology Data Exchange (ETDEWEB)

    Bahadori, A. [Curtin University of Technology, Perth, WA (Australia)

    2011-06-15

    When cooling combustion flue gas for heat recovery and efficiency gain, the temperature must not be allowed to drop below the sulfur trioxide dew point. Below the SO{sub 3} dew point, very corrosive sulfuric acid forms and leads to operational hazards on metal surfaces. In the present work, simple-to-use predictive tool, which is easier than existing approaches, less complicated with fewer computations is formulated to arrive at an appropriate estimation of acid dew point during combustion flue gas cooling which depends on fuel type, sulfur content in fuel, and excess air levels. The resulting information can then be applied to estimate the acid dew point, for sulfur in various fuels up to 0.10 volume fraction in gas (0.10 mass fraction in liquid), excess air fractions up to 0.25, and elemental concentrations of carbon up to 3. The proposed predictive tool shows a very good agreement with the reported data wherein the average absolute deviation percent was found to be around 3.18%. This approach can be of immense practical value for engineers and scientists for a quick estimation of acid dew point during combustion flue gas cooling for heat recovery and efficiency gain for wide range of operating conditions without the necessity of any pilot plant setup and tedious experimental trials. In particular, process and combustion engineers would find the tool to be user friendly involving transparent calculations with no complex expressions for their applications.

  15. An energetic analysis of CO2 capture on a gas turbine combining flue gas recirculation and membrane separation

    International Nuclear Information System (INIS)

    Belaissaoui, Bouchra; Cabot, Gilles; Cabot, Marie-Sophie; Willson, David; Favre, Eric

    2012-01-01

    Post-combustion Carbon Capture and Storage (CCS) is currently intensively investigated as a key issue for the mitigation of greenhouse gases emissions. A very large number of studies is dedicated to coal power plants. In this paper, the possibility to achieve carbon capture on a gas turbine, based on a combination of flue gas recycle and membrane separation is reported. Membrane processes are effectively known to offer attractive performances in terms of energy efficiency, as soon as concentrated and/or pressure mixtures have to be treated. Two different flow schemes have been simulated and compared: flue gas recycle with air combustion and flue gas recycle with an oxygen enriched feed mixture. The energy requirement of the different processes, expressed in GJ (thermal basis) per ton of recovered CO 2 , and the size of the membrane capture process (expressed in m 2 of membrane area) have been systematically estimated for different membrane separation performances. It is shown that an overall energy requirement down to 2.6 GJ per ton can possibly be achieved when optimal operating conditions, based on oxygen enriched air (OEA) combustion together with a highly selective membrane (CO 2 /N 2 selectivity of 200) are combined. Additional possibilities in order to minimise the energy penalty of the process are discussed. -- Highlights: ► A carbon capture process for gas turbine has been investigated for the first time, with membrane separation unit. ► Air combustion systematically induces CO 2 capture specific energy requirement far above alternative capture processes. ► Remarkably, a very low energy requirement can be achieved (down to 2.6 GJ/ton) with Oxygen Enriched Air combustion. ► Target membrane selectivities and optimal oxygen content for combustion have been identified.

  16. Biomass fast pyrolysis for bio-oil production in a fluidized bed reactor under hot flue atmosphere.

    Science.gov (United States)

    Li, Ning; Wang, Xiang; Bai, Xueyuan; Li, Zhihe; Zhang, Ying

    2015-10-01

    Fast pyrolysis experiments of corn stalk were performed to investigate the optimal pyrolysis conditions of temperature and bed material for maximum bio-oil production under flue gas atmosphere. Under the optimized pyrolysis conditions, furfural residue, xylose residue and kelp seaweed were pyrolyzed to examine their yield distributions of products, and the physical characteristics of bio-oil were studied. The best flow rate of the flue gas at selected temperature is obtained, and the pyrolysis temperature at 500 degrees C and dolomite as bed material could give a maximum bio-oil yield. The highest bio-oil yield of 43.3% (W/W) was achieved from corn stalk under the optimal conditions. Two main fractions were recovered from the stratified bio-oils: light oils and heavy oils. The physical properties of heavy oils from all feedstocks varied little. The calorific values of heavy oils were much higher than that of light oils. The pyrolysis gas could be used as a gaseous fuel due to a relatively high calorific value of 6.5-8.5 MJ/m3.

  17. CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS

    Energy Technology Data Exchange (ETDEWEB)

    David A. Green; Brian S. Turk; Raghubir P. Gupta; Alejandro Lopez-Ortiz; Douglas P. Harrison; Ya Liang

    2001-07-01

    Sodium based sorbents including sodium carbonate may be used to capture carbon dioxide from flue gas. A relatively concentrated carbon dioxide stream may be recoverable for sequestration when the sorbent is regenerated. Electrobalance tests indicated that sodium carbonate monohydrate was formed in a mixture of helium and water vapor at temperatures below 65 C. Additional compounds may also form, but this could not be confirmed. In the presence of carbon dioxide and water vapor, both the initial reaction rate of sodium carbonate with carbon dioxide and water and the sorbent capacity decreased with increasing temperature, consistent with the results from the previous quarter. Increasing the carbon dioxide concentration at constant temperature and water vapor concentration produced a measurable increase in rate, as did increasing the water vapor concentration at constant carbon dioxide concentration and temperature. Runs conducted with a flatter TGA pan resulted in a higher initial reaction rate, presumably due to improved gas-solid contact, but after a short time, there was no significant difference in the rates measured with the different pans. Analyses of kinetic data suggest that the surface of the sodium carbonate particles may be much hotter than the bulk gas due to the highly exothermic reaction with carbon dioxide and water, and that the rate of heat removal from the particle may control the reaction rate. A material and energy balance was developed for a cyclic carbonation/calcination process which captures about 26 percent of the carbon dioxide present in flue gas available at 250 C.

  18. Results using flue gas desulfurization gypsum in soilless substrates for greenhouse crops

    Science.gov (United States)

    Recent availability of Flue Gas Desulfurization gypsum (FGDG) has led to interested in its possible use in horticulture greenhouse production. Three studies were conducted to determine the effects of increasing rates of FGDG on six greenhouse crops. In the first study, substrates (6:1 pine bark:san...

  19. Heterogeneous reactions and aerosol formation in flue gas cleaning by electron beam

    International Nuclear Information System (INIS)

    Baumann, W.; Jordan, S.; Leichsenring, C.H.; Maetzing, H.; Paur, H.R.; Schikarski, W.

    1990-08-01

    The electron beam dry scrubbing process is a simultaneous method for the removal of SO 2 and NO x from flue gas. By electron irradiation radicals (OH, O 2 H, O) are formed from the main flue gas components which oxidize NO x and SO 2 into the acids HNO 3 and H 2 SO 4 . These are then neutralized by the injection of NH 3 . A submicron aerosol consisting of ammonium salts is formed which is filtered from the offgas. The main pathways of the gas phase chemistry and product formation have been elucidated by experimental and theoretical studies. Back reactions which occur in the gas and the particle phase limit the energy efficiency of the process. By recirculation of irradiated gas into the reaction vessel (multiple irradiation) a significant improvement of removal yields was obtained. This enhancement of the energy efficiency requires the removal of products between the irradiation steps. Studies show that the material balance is complete. Deficits in the N and S balance of the process are due to the additional formation of molecular nitrogen and the deposition of ammonium sulfate in the ducts. Aerosol formation participates only with 30% in the material balance. The remaining 70% of the product are formed by surface reactions in the filter cake (40%) and in the ducts (30%). (orig.) With 38 figs., 29 tabs [de

  20. Ecological aspects of coal combustion - utilization of CO2 from flue gas

    Directory of Open Access Journals (Sweden)

    Markoš Jozef

    1998-09-01

    Full Text Available Slovakia belongs to the group of twenty worst polluters throughout the world, releasing 10 - 12 tons of carbon dioxide per capita, whereas the worldwide average value is about 5 tons. It is known that the big electric and thermal power stations produce only 25 % of the overall production of carbon dioxide in Slovakia, whereas the biggest producer of carbon dioxide is the industry by 31%. The aim of the present contribution is to show possibilities of the further chemical conversion of the separated carbon dioxide from flue gas as a chemical raw material. We focused our attention to the feasibility of the conversion of carbon dioxide into carbon oxide or synthesis gas and its further conversion into methanol. The production of synthesis gas from carbon dioxide, coke (coal and natural gas was assumed. On the basis of our studies we can claim that the fulfilment of the national target of the Slovak Republic set up for 2005, i.e., the reduction of carbon dioxide emissions by 20 % against 1988 by the chemical transformation of carbon dioxide from the electric power stations flue gas is not realistic. In our opinion a profound reduction of carbon dioxide emission can be reached by lower demands for energy produced by burning fossil fuels or by the substitution of these fuels by alternative energy sources.

  1. Technical and economic feasibility study of flue gas injection in an Iranian oil field

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ahmadi

    2015-09-01

    The main aim of this research is to investigate various gas injection methods (N2, CO2, produced reservoir gas, and flue gas in one of the northern Persian gulf oil fields by a numerical simulation method. Moreover, for each scenario of gas injection technical and economical considerations are took into account. Finally, an economic analysis is implemented to compare the net present value (NPV of the different gas injection scenarios in the aforementioned oil field.

  2. State of the art of flue gas desulphurisation in power plants; Stand der Technik bei Rauchgasreinigungsanlagen in Grosskraftwerken

    Energy Technology Data Exchange (ETDEWEB)

    Heiting, Bernd [VGB PowerTech e.V., Essen (Germany)

    2011-07-01

    Published measured data from modern power plants erected in the 80s show little emission concentrations of heavy metal and fine dust particles. Very low emission concentrations are also expected for new power plants, which are in the planning or erection phase, due to the flue gas cleaning stages DENOX, flue gas cooling in air pre-heater, ESP and FGD scrubber. Mercury components are also effectively removed through the combination high-dust SCR plant and FGD absorber. (orig.)

  3. Re-use of stabilised flue gas ashes from solid waste incineration in cement-treated base layers for pavements

    DEFF Research Database (Denmark)

    Cai, Zuansi; Jensen, Dorthe Lærke; Christensen, Thomas Højlund

    2003-01-01

    Fly ash from coal-burning power plants has been used extensively as a pozzolan and fine filter in concrete for many years. Laboratory experiments were performed investigating the effect of substituting the coal-based fly ash with chemically stabilised flue gas ashes (FGA) from waste incineration...... more than 5 MPa after 7 days. The tank leaching tests revealed that leaching of heavy metals was not significantly affected by the use of chemically stabilised flue gas ashes from waste incineration. Assuming that diffusion controls the leaching process it was calculated that less than 1% of the metals...... would teach during a 100-year period from a 0.5 m thick concrete stab exposed to water on one side. Leaching of the common ions Ca, Cl, Na and SO4 was increased 3-20 times from the specimens with chemically stabilised flue gas ashes from waste incineration. However, the quantities leached were still...

  4. Flue gas recovery system for natural gas combined heat and power plant with distributed peak-shaving heat pumps

    International Nuclear Information System (INIS)

    Zhao, Xiling; Fu, Lin; Wang, Xiaoyin; Sun, Tao; Wang, Jingyi; Zhang, Shigang

    2017-01-01

    Highlights: • A flue gas recovery system with distributed peak-shaving heat pumps is proposed. • The system can improve network transmission and distribution capacity. • The system is advantageous in energy saving, emission reduction and economic benefits. - Abstract: District heating systems use distributed heat pump peak-shaving technology to adjust heat in secondary networks of substations. This technology simultaneously adjusts the heat of the secondary network and reduces the return-water temperature of the primary network by using the heat pump principle. When optimized, low temperature return-water is able to recycle more waste heat, thereby further improving the heating efficiency of the system. This paper introduces a flue gas recovery system for a natural gas combined heat and power plant with distributed peak-shaving heat pumps. A pilot system comprising a set of two 9F gas-steam combined cycle-back pressure heating units was used to analyse the system configuration and key parameters. The proposed system improved the network transmission and distribution capacity, increased heating capacity, and reduced heating energy consumption without compromising heating safety issues. As such, the proposed system is advantageous in terms of energy saving, emission reduction, and economic benefits.

  5. Facile synthesis of triazine-triphenylamine-based microporous covalent polymer adsorbent for flue gas CO2 capture

    KAUST Repository

    Das, Swapan Kumar; Wang, Xinbo; Lai, Zhiping

    2017-01-01

    The sustainable capture and sequestration of CO2 from flue gas emission is an important and unavoidable challenge to control greenhouse gas release and climate change. In this report, we describe a triazine-triphenylamine-based microporous covalent

  6. Flue gas desulphurization in a spray tower with de-coupled recycling of soda ash

    Energy Technology Data Exchange (ETDEWEB)

    Liebgott, H.

    1983-05-01

    RD project to develop a ''dry'' process for the desulphurization of flue gases. The process is based on a desulphurization step with a solution of soda ash which is sprayed into the flue gas. The gas is cooled by evaporation but its temperature is still higher than the dew point; reheating is not necessary. The product of the desulphurization is a dry mixture of sodium sulphite and -carbonate. It is intended to reprocess this powder to soda in a central plant - serving several power stations. First sulphite is oxidized to sulphate, which in turn is reacted with calcium chloride to form calcium sulphate and sodium chloride. The latter is introduced into the Solvay-soda ash process which yields calcium chloride as a by-product. Tests were carried out for the desulphurization step and the oxidation of sulphite. The desulphurization tests resulted in poor degrees of SO/sub 2/-removal even with high stoichiometric ratios of soda ash to sulphur dioxide. The preliminary estimates of process economics made before start of experimental work could not be verified. Furthermore, during work on the project, new processes were revealed whereby flue gas is desulphurized in a spray-drying apparatus with a slurry of calcium hydroxide. In an extension of the project, tests were carried out which confirmed these findings. The project was abandoned.

  7. A technical pilot plant assessment of flue gas desulfurisation in a circulating fluidised bed

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, F.J.; Ollero, P. [Universidad de Sevilla (Spain). Dept. de Ingenieria Quimica y Ambiental; Cabanillas, A.; Otero, J. [Centro de Investigaciones Energeticas y Medioambientales, (CIEMAT), Madrid (Spain)

    2002-11-01

    Flue gas desulfurisation in a circulating fluidised bed absorber (CFBA) is quite a novel dry desulfurisation technology [6th International Conference on Circulating Fluidised Beds (1999) 601] that shows significant advantages in comparison with other dry technologies and that could also be competitive with the widely-used wet FGD technology. This experimental study analyses the performance of a flue gas treatment plant comprising a CFBA and an electrostatic precipitator (ESP). The most significant aspects considered in this study are: the effect of precollecting the fly ash, the effect of the SO{sub 2} inlet concentration, the effect of power plant load changes, the contribution of the final particulate control equipment to the overall SO{sub 2} removal efficiency and the impact of the desulfurisation unit on the ESP behaviour and its final dust emissions. In addition, the behaviour of the integrated CFBA-ESP system with respect to the main operating parameters was studied by means of a fractional factorial design of experiments. All this experimental work was carried out in a 3-MWe equivalent pilot plant that processes real gases withdrawn from the Los Barrios Power Plant. Processing a flue gas with up to 2000 ppm SO{sub 2} concentration, a sulfur removal of 95-97% with a lime utilisation of 75% was achieved. A simple regression model to evaluate the efficiency of the whole system is also proposed.(author)

  8. ADVANCED FLUE GAS CONDITIONING AS A RETROFIT UPGRADE TO ENHANCE PM COLLECTION FROM COAL-FIRED ELECTRIC UTILITY BOILERS

    International Nuclear Information System (INIS)

    Kenneth E. Baldrey

    2002-01-01

    The U.S. Department of Energy and ADA Environmental Solutions are engaged in a project to develop commercial flue gas conditioning additives. The objective is to develop conditioning agents that can help improve particulate control performance of smaller or under-sized electrostatic precipitators on utility coal-fired boilers. The new chemicals will be used to control both the electrical resistivity and the adhesion or cohesivity of the fly ash. There is a need to provide cost-effective and safer alternatives to traditional flue gas conditioning with SO(sub 3) and ammonia. During this reporting quarter, performance testing of flue gas conditioning was underway at the PacifiCorp Jim Bridger Power Plant. The product tested, ADA-43, was a combination resistivity modifier with cohesivity polymers. This represents the first long-term full-scale testing of this class of products. Modifications to the flue gas conditioning system at Jim Bridger, including development of alternate injection lances, was also undertaken to improve chemical spray distribution and to avoid spray deposition to duct interior surfaces. Also in this quarter, a firm commitment was received for another long-term test of the cohesivity additives. This plant fires a bituminous coal and has opacity and particulate emissions performance issues related to fly ash re-entrainment. Ammonia conditioning is employed here on one unit, but there is interest in liquid cohesivity additives as a safer alternative

  9. Simulation of a heat pump system for total heat recovery from flue gas

    International Nuclear Information System (INIS)

    Wei, Maolin; Yuan, Weixing; Song, Zhijia; Fu, Lin; Zhang, Shigang

    2015-01-01

    This paper introduces an approach of using an open-cycle absorption heat pump (OAHP) for recovering waste heat from the flue gas of a gas boiler with a system model. And equivalent energy efficiency is used to evaluate two other heat recovery systems that integrate an electric compression heat pump (EHP) or an absorption heat pump (AHP) with a boiler. The key factors influencing the systems are evaluated. The OAHP system efficiency is improved by 11% compared to the base case. And the OAHP system is more efficient than the AHP or the EHP systems, especially when the solution mass flow rate is only a little less than the cold water mass flow rate. The energy efficiency comparison is supplemented with a simplified economic analysis. The results indicate that the OAHP system is the best choice for the current prices of electricity and natural gas in Beijing. - Highlights: • An OAHP system is analyzed to improve heat recovery from natural gas flue gas. • OAHP system models are presented and analyzed. • The key factors influencing the OAHP systems are analyzed. • The OAHP system is most efficient for most cases compared with other systems. • The OAHP system is more economic than other systems

  10. Flue gas wells to minimize dust and acidic components in small-scale burning of field fuel, further development; Roekgasbrunn foer minimering av stoft och sura komponenter vid smaaskalig foerbraenning av aakerbraenslen, vidareutveckling

    Energy Technology Data Exchange (ETDEWEB)

    Yngvesson, Johan; Roennbaeck, Marie; Arkeloev, Olof

    2011-01-15

    Agricultural derived solid fuels are more problematic to combust in small-scale heating plants than conventional wood fuels. Their high content of ash, chlorine and sulphur leads to increased emissions of dust, sulphur dioxide and hydrogen chloride in the flue gases. By transporting the flue gases to a flue gas well where it condenses, and separates dust and sour components, enables a cost effective flue gas purification for small-scale heating plants (50 kW - 10 MW) of agricultural derived solid fuels. This project have studied two heating plants using flue gas wells with the aim to add to the knowledge about how a flue gas wells may look like and to quantify how much emissions of dust, chlorine and sulphur in the flue gases are reduced. The project also aimed to summon regulations and laws regarding the handling of the condensate that develop in the flue gas well. In the project measures were conducted on two different heating plants with mounted flue gas wells: a 60 kW biofuels boiler combusting grains and red canary grass and a 1 MW batch fired boiler combusting wheat straw. Measurements on flue gases were conducted with and without water injection in the flue gases. The flue gas wells reduced dust emissions of up to 80 %. The best reduction was achieved at the 60 kW heating plant when firing red canary grass. Firing grains in the same plant lead to 7 % reduction of the dust emissions. In the 1 MW heating plant firing wheat straw the flue gas well accomplished 40 % reduction of dust emissions. The boiler ability to achieve complete combustion, hence minimize the content of volatile and semi-volatile components in the flue gas, is largely affecting the flue gas well ability to reduce dust emissions. This did not, however, affect the reduction of dust in the flue. Chlorine emissions was reduced by up to 88 % by a flue gas well. Water injection made a big difference on reduction of chlorine emission from grain combustion. Sulphur emissions was reduced by 50

  11. Experimental investigation of a pilot-scale jet bubbling reactor for wet flue gas desulphurisation

    DEFF Research Database (Denmark)

    Zheng, Yuanjing; Kiil, Søren; Johnsson, Jan Erik

    2003-01-01

    In the present work, an experimental parameter study was conducted in a pilot-scale jet bubbling reactor for wet flue gas desulphurisation (FGD). The pilot plant is downscaled from a limestone-based, gypsum producing full-scale wet FGD plant. Important process parameters, such as slurry pH, inlet...... flue gas concentration of SO2, reactor temperature, and slurry concentration of Cl- have been varied. The degree of desulphurisation, residual limestone content of the gypsum, liquid phase concentrations, and solids content of the slurry were measured during the experimental series. The SO2 removal...... efficiency increased from 66.1% to 71.5% when the reactor slurry pH was changed from 3.5 to 5.5. Addition of Cl(in the form of CaCl2 . 2H(2)O) to the slurry (25 g Cl-/l) increased the degree of desulphurisation to above 99%, due to the onset of extensive foaming, which substantially increased the gas...

  12. New configurations of a heat recovery absorption heat pump integrated with a natural gas boiler for boiler efficiency improvement

    International Nuclear Information System (INIS)

    Qu, Ming; Abdelaziz, Omar; Yin, Hongxi

    2014-01-01

    Highlights: • Thermal and heat transfer models of absorption heat pumps driven by exhaust gas, hot water, or natural gas. • Natural gas boiler combustion model. • Heat exchanger for condensing. • Experimental data of a hot water absorption heat pump. • Economic assessment of heat recovery absorption heat pump for improving natural gas boilers. - Abstract: Conventional natural gas-fired boilers exhaust flue gas direct to the atmosphere at 150–200 °C, which, at such temperatures, contains large amount of energy and results in relatively low thermal efficiency ranging from 70% to 80%. Although condensing boilers for recovering the heat in the flue gas have been developed over the past 40 years, their present market share is still less than 25%. The major reason for this relatively slow acceptance is the limited improvement in the thermal efficiency of condensing boilers. In the condensing boiler, the temperature of the hot water return at the range of 50–60 °C, which is used to cool the flue gas, is very close to the dew point of the water vapor in the flue gas. Therefore, the latent heat, the majority of the waste heat in the flue gas, which is contained in the water vapor, cannot be recovered. This paper presents a new approach to improve boiler thermal efficiency by integrating absorption heat pumps with natural gas boilers for waste heat recovery (HRAHP). Three configurations of HRAHPs are introduced and discussed. The three configurations are modeled in detail to illustrate the significant thermal efficiency improvement they attain. Further, for conceptual proof and validation, an existing hot water-driven absorption chiller is operated as a heat pump at operating conditions similar to one of the devised configurations. An overall system performance and economic analysis are provided for decision-making and as evidence of the potential benefits. These three configurations of HRAHP provide a pathway to achieving realistic high-efficiency natural

  13. Removal of mercury (II), elemental mercury and arsenic from simulated flue gas by ammonium sulphide.

    Science.gov (United States)

    Ning, Ping; Guo, Xiaolong; Wang, Xueqian; Wang, Ping; Ma, Yixing; Lan, Yi

    2015-01-01

    A tubular resistance furnace was used as a reactor to simulate mercury and arsenic in smelter flue gases by heating mercury and arsenic compounds. The flue gas containing Hg(2+), Hg(0) and As was treated with ammonium sulphide. The experiment was conducted to investigate the effects of varying the concentration of ammonium sulphide, the pH value of ammonium sulphide, the temperature of ammonium sulphide, the presence of SO2 and the presence of sulphite ion on removal efficiency. The prepared adsorption products were characterized by Fourier transform infrared spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy and scanning electron microscopy. The results showed that the optimal concentration of ammonium sulphide was 0.8 mol/L. The optimal pH value of ammonium sulphide was 10, and the optimal temperature of ammonium sulphide was 20°C.Under the optimum conditions, the removal efficiency of Hg(2+), Hg(0) and As could reach 99%, 88.8%, 98%, respectively. In addition, SO2 and sulphite ion could reduce the removal efficiency of mercury and arsenic from simulated flue gas.

  14. Amino acid salt solutions as solvents in CO2 capture from flue gas

    DEFF Research Database (Denmark)

    Lerche, Benedicte Mai; Thomsen, Kaj; Stenby, Erling Halfdan

    New solvents based on the salts of amino acids have emerged as an alternative to the alkanolamine solutions, for the chemical absorption of CO2 from flue gas. But only few studies on amino acids as CO2 capturing agents have been performed so far. One of the interesting features of amino acid salt...... solutions is their ability to form solid precipitates upon the absorption of CO2. The occurrence of crystallization offers the possibility of increasing the CO2 loading capacity of the solvent. However, precipitation can also have negative effect on the CO2 capture process. The chemical nature of the solid...... of glycine, taurine, and lysine, while in the case of proline, and glutamic acid, the precipitate was found to be bicarbonate. These results give an important contribution to further understanding the potential of amino acid salt solutions in CO2 capture from flue gas....

  15. Separation of carbon dioxide from flue gas by mixed matrix membranes using dual phase microporous polymeric constituents.

    Science.gov (United States)

    Sekizkardes, Ali K; Kusuma, Victor A; Dahe, Ganpat; Roth, Elliot A; Hill, Lawrence J; Marti, Anne; Macala, Megan; Venna, Surendar R; Hopkinson, David

    2016-09-27

    This study presents the fabrication of a new mixed matrix membrane using two microporous polymers: a polymer of intrinsic microporosity PIM-1 and a benzimidazole linked polymer, BILP-101, and their CO 2 separation properties from post-combustion flue gas. 17, 30 and 40 wt% loadings of BILP-101 into PIM-1 were tested, resulting in mechanically stable films showing very good interfacial interaction due to the inherent H-bonding capability of the constituent materials. Gas transport studies showed that BILP-101/PIM-1 membranes exhibit high CO 2 permeability (7200 Barrer) and selectivity over N 2 (15). The selected hybrid membrane was further tested for CO 2 separation using actual flue gas from a coal-fired power plant.

  16. Retrofit flue gas desulfurization system at Indianapolis Power and Light Co. Petersburg Station Units 1 and 2

    International Nuclear Information System (INIS)

    Watson, W.K.; Wolsiffer, S.R.; Youmans, J.; Martin, J.E.; Wedig, C.P.

    1992-01-01

    This paper briefly describes the status of the retrofit wet limestone flue gas desulfurization system (FGDS) project at Indianapolis Power and Light Company (IPL), Petersburg Units 1 and 2. This project was initiated by IPL in response to the Clean Air Act of 1990 and is intended to treat the flue gas from two base load units with a combined capacity of approximately 700 MW gross electrical output. IPL is the owner and operator of the Petersburg Station located in southwestern Indiana. Stone and Webster Engineering Corporation (Stone and Webster) is the Engineer and Constructor for the project. Radian Corporation is a subcontractor to Stone and Webster in the area of flue gas desulfurization (FGD) process. General Electric Environmental Systems, Inc. (GEESI) is the supplier of the FGDS. The project is organized as a team with each company providing services. The supplier of the new stack is scheduled to be selected and join the team in early 1992. Other material suppliers and field contractors will be selected in 1992

  17. Carbon Dioxide Capture from Flue Gas Using Dry Regenerable Sorbents

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Nelson; David Green; Paul Box; Raghubir Gupta; Gennar Henningsen

    2007-06-30

    Regenerable sorbents based on sodium carbonate (Na{sub 2}CO{sub 3}) can be used to separate carbon dioxide (CO{sub 2}) from coal-fired power plant flue gas. Upon thermal regeneration and condensation of water vapor, CO{sub 2} is released in a concentrated form that is suitable for reuse or sequestration. During the research project described in this report, the technical feasibility and economic viability of a thermal-swing CO{sub 2} separation process based on dry, regenerable, carbonate sorbents was confirmed. This process was designated as RTI's Dry Carbonate Process. RTI tested the Dry Carbonate Process through various research phases including thermogravimetric analysis (TGA); bench-scale fixed-bed, bench-scale fluidized-bed, bench-scale co-current downflow reactor testing; pilot-scale entrained-bed testing; and bench-scale demonstration testing with actual coal-fired flue gas. All phases of testing showed the feasibility of the process to capture greater than 90% of the CO{sub 2} present in coal-fired flue gas. Attrition-resistant sorbents were developed, and these sorbents were found to retain their CO{sub 2} removal activity through multiple cycles of adsorption and regeneration. The sodium carbonate-based sorbents developed by RTI react with CO{sub 2} and water vapor at temperatures below 80 C to form sodium bicarbonate (NaHCO3) and/or Wegscheider's salt. This reaction is reversed at temperatures greater than 120 C to release an equimolar mixture of CO{sub 2} and water vapor. After condensation of the water, a pure CO{sub 2} stream can be obtained. TGA testing showed that the Na{sub 2}CO3 sorbents react irreversibly with sulfur dioxide (SO{sub 2}) and hydrogen chloride (HCl) (at the operating conditions for this process). Trace levels of these contaminants are expected to be present in desulfurized flue gas. The sorbents did not collect detectable quantities of mercury (Hg). A process was designed for the Na{sub 2}CO{sub 3}-based sorbent that

  18. Membrane Process to Capture CO{sub 2} from Coal-Fired Power Plant Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Merkel, Tim; Wei, Xiaotong; Firat, Bilgen; He, Jenny; Amo, Karl; Pande, Saurabh; Baker, Richard; Wijmans, Hans; Bhown, Abhoyjit

    2012-03-31

    This final report describes work conducted for the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL) on development of an efficient membrane process to capture carbon dioxide (CO{sub 2}) from power plant flue gas (award number DE-NT0005312). The primary goal of this research program was to demonstrate, in a field test, the ability of a membrane process to capture up to 90% of CO{sub 2} in coal-fired flue gas, and to evaluate the potential of a full-scale version of the process to perform this separation with less than a 35% increase in the levelized cost of electricity (LCOE). Membrane Technology and Research (MTR) conducted this project in collaboration with Arizona Public Services (APS), who hosted a membrane field test at their Cholla coal-fired power plant, and the Electric Power Research Institute (EPRI) and WorleyParsons (WP), who performed a comparative cost analysis of the proposed membrane CO{sub 2} capture process. The work conducted for this project included membrane and module development, slipstream testing of commercial-sized modules with natural gas and coal-fired flue gas, process design optimization, and a detailed systems and cost analysis of a membrane retrofit to a commercial power plant. The Polaris? membrane developed over a number of years by MTR represents a step-change improvement in CO{sub 2} permeance compared to previous commercial CO{sub 2}-selective membranes. During this project, membrane optimization work resulted in a further doubling of the CO{sub 2} permeance of Polaris membrane while maintaining the CO{sub 2}/N{sub 2} selectivity. This is an important accomplishment because increased CO{sub 2} permeance directly impacts the membrane skid cost and footprint: a doubling of CO{sub 2} permeance halves the skid cost and footprint. In addition to providing high CO{sub 2} permeance, flue gas CO{sub 2} capture membranes must be stable in the presence of contaminants including SO{sub 2}. Laboratory tests showed no

  19. Performance evaluation of a green process for microalgal CO2 sequestration in closed photobioreactor using flue gas generated in-situ.

    Science.gov (United States)

    Yadav, Geetanjali; Karemore, Ankush; Dash, Sukanta Kumar; Sen, Ramkrishna

    2015-09-01

    In the present study, carbon-dioxide capture from in situ generated flue gas was carried out using Chlorella sp. in bubble column photobioreactors to develop a cost effective process for concomitant carbon sequestration and biomass production. Firstly, a comparative analysis of CO2 sequestration with varying concentrations of CO2 in air-CO2 and air-flue gas mixtures was performed. Chlorella sp. was found to be tolerant to 5% CO2 concentration. Subsequently, inhibitory effect of pure flue gas was minimized using various strategies like use of high initial cell density and photobioreactors in series. The final biofixation efficiency was improved by 54% using the adopted strategies. Further, sequestered microalgal biomass was analyzed for various biochemical constituents for their use in food, feed or biofuel applications. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Mixotrophic cultivation of oleaginous Chlorella sp. KR-1 mediated by actual coal-fired flue gas for biodiesel production.

    Science.gov (United States)

    Praveenkumar, Ramasamy; Kim, Bohwa; Choi, Eunji; Lee, Kyubock; Cho, Sunja; Hyun, Ju-Soo; Park, Ji-Yeon; Lee, Young-Chul; Lee, Hyun Uk; Lee, Jin-Suk; Oh, You-Kwan

    2014-10-01

    Flue gases mainly consist of CO2 that can be utilized to facilitate microalgal culture for bioenergy production. In the present study, to evaluate the feasibility of the utilization of flue gas from a coal-burning power plant, an indigenous and high-CO2-tolerant oleaginous microalga, Chlorella sp. KR-1, was cultivated under mixotrophic conditions, and the results were evaluated. When the culture was mediated by flue gas, highest biomass (0.8 g cells/L·d) and FAME (fatty acid methyl esters) productivity (121 mg/L·d) were achieved in the mixotrophic mode with 5 g/L glucose, 5 mM nitrate, and a flow rate of 0.2 vvm. By contrast, the photoautotrophic cultivation resulted in a lower biomass (0.45 g cells/L·d) and a lower FAME productivity (60.2 mg/L·d). In general, the fatty acid profiles of Chlorella sp. KR-1 revealed meaningful contents (>40 % of saturated and mono-unsaturated fatty acids) under the mixotrophic condition, which enables the obtainment of a better quality of biodiesel than is possible under the autotrophic condition. Conclusively then, it was established that a microalgal culture mediated by flue gas can be improved by adoption of mixotrophic cultivation systems.

  1. Process using sorbents for the removal of SOx from flue gas

    International Nuclear Information System (INIS)

    Pinnavaia, T.J.; Amareskera, J.; Polansky, C.A.

    1992-01-01

    This patent describes a process for removing the SO x components from a flue gas stream containing oxygen, sulfur dioxide and sulfur trioxide from the combustion of coal from a coal-fired boiler which comprises combusting the coal in the boiler to provide the flue gas stream and contacting the the gas stream with a heated sorbent composition at 400 degrees to 1000 degrees C wherein the the sorbent before being heated is selected from the group consisting of a layered double hydroxide composition of formula: [M 1-x II M x III (OH) 2 ](A n- ) x/n · yH 2 O wherein M II is a divalent metal cation and M III is a trivalent metal cation selected from the group consisting of Group IIA. IIB and IIIA metals as the cation which form metal oxides and which are capable of reacting with SO 2 to form metal sulfites and SO 3 to form metal sulfates, A is an interlayer anion of charge n- which comprises at least one metal atoms selected from the group consisting of main group metals and transition metals which provide oxidation of sulfur dioxide to sulfur trioxide in an amount sufficient that the layered double hydroxide structure promotes the oxidation of the sulfur dioxide to the sulfur trioxide at the combustion conditions within the coal-fired boiler, wherein y is moles of water

  2. Purification technology for flue/off gases using electron beams

    International Nuclear Information System (INIS)

    Kojima, Takuji

    2004-01-01

    The present paper describes research and development on purification technology using electron beams for flue/off gases containing pollutants: removal of sulfate oxide and nitrogen oxide from flue gases of coal/oil combustion power plants, decomposition of dioxins in waste incineration flue gas, and decomposition/removal of toxic volatile organic compounds from off gas. (author)

  3. Investigation of the chemical pathway of gaseous nitrogen dioxide formation during flue gas desulfurization with dry sodium bicarbonate injection

    Science.gov (United States)

    Stein, Antoinette Weil

    The chemical reaction pathway for the viable flue gas desulfurization process, dry sodium bicarbonate injection, was investigated to mitigate undesirable plume discoloration. Based on a foundation of past findings, a simplified three-step reaction pathway was hypothesized for the formation of the plume-discoloring constituent, NO2. As the first step, it was hypothesized that sodium sulfite formed by sodium bicarbonate reaction with flue gas SO 2. As the second step, it was hypothesized that sodium nitrate formed by sodium sulfite reaction with flue gas NO. And as the third step, it was hypothesized that NO2 and sodium sulfate formed by sodium nitrate reaction with SO2. The second and third hypothesized steps were experimentally investigated using an isothermal fixed bed reactor. As reported in the past, technical grade sodium sulfite was found to be un-reactive with NO and O2. Freshly prepared sodium sulfite, maintained unexposed to moist air, was shown to react with NO and O2 resulting in a mixture of sodium nitrite and sodium nitrate together with a significant temperature rise. This reaction was found to proceed only when oxygen was present in the flue gas. As reported in the past, technical grade sodium nitrate was shown to be un-reactive with SO2. But freshly formed sodium nitrate kept unexposed to humidity was found to be reactive with SO2 and O 2 resulting in the formation of NO2 and sodium sulfate polymorphic Form I. The NO2 formation by this reaction was shown to be temperature dependent with maximum formation at 175°C. Plume mitigation methods were studied based on the validated three-step reaction pathway. Mitigation of NO2 was exhibited by limiting oxygen concentration in the flue gas to a level below 5%. It was also shown that significant NO2 mitigation was achieved by operating below 110°C or above 250°C. An innovative NO2 mitigation method was patented as a result of the findings of this study. The patented process incorporated a process step of

  4. Revegetation of flue gas desulfurization sludge pond disposal sites

    International Nuclear Information System (INIS)

    Artiola, J.F.

    1994-12-01

    A comprehensive search of published literature was conducted to summarize research undertaken to date on revegetation of flue gas desulfurization (FGD) waste disposal ponds. A review of the physical and chemical properties of FGD sludges and wastes with similar characteristics is also included in order to determine the advantages and limitations of FGD sludge for plant growth. No specific guidelines have been developed for the revegetation of FGD sludge disposal sites. Survey studies showed that the wide-ranging composition of FGD wastes was determined primarily by the sulfur dioxide and other flue gas scrubbing processes used at powerplants. Sulfate rich (>90%CaSO 4 ) FGD sludges are physically and chemically more stable, and thus more amenable to revegetation. Because of lack of macronutrients and extremely limited microbial activity, FBD sludge ponds presented a poor plant growth environment without amendment. Studies showed the natural process of inoculation of the FGD sludge with soil microbes that promote plant growth be can after disposal but proceeded slowly. Revegetation studies reviewed showed that FGD sludges amended with soils supported a wider variety of plant species better and longer than abandoned FGD ponds. Two major types of plants have been successful in revegetation of FGD waste ponds and similar wastes: salt-tolerant plants and aquatic plants. A comprehensive list of plant species with potential for regetation of FGD sludge disposal pond sites is presented along with successful revegetation techniques

  5. Investigation of sewage sludge gasification with use of flue gas as a gasifying agent

    Directory of Open Access Journals (Sweden)

    Maj Izabella

    2017-01-01

    Full Text Available The paper presents results of investigation of low-temperature sewage sludge gasification with use of flue gas as a gasifying agent. Tests were conducted in a laboratory stand, equipped with a gasification reactor designed and constructed specifically for this purpose. During presented tests, gas mixture with a composition of typical flue gases was used as a gasifying agent. The measuring system ensures online measurements of syngas composition: CO, CO2, H2, CH4. As a result of gasification process a syngas with combustible components has been obtained. The aim of the research was to determine the usability of sewage sludge for indirect cofiring in power boilers with the use of flue gas from the boiler as a gasifying agent and recirculating the syngas to the boiler’s combustion chamber. Results of presented investigation will be used as a knowledge base for industrial-scale sewage sludge gasification process. Furthermore, toxicity of solid products of the process has been determined by the use of Microtox bioassay. Before tests, solid post-gasification residues have been ground to two particle size fractions and extracted into Milli-Q water. The response of test organisms (bioluminescent Aliivibrio fischeri bacteria in reference to a control sample (bacteria exposed to 2% NaCl solution was measured after 5 and 15 minutes of exposure. The obtained toxicity results proved that thermal treatment of sewage sludge by their gasification reduces their toxicity relative to water organisms.

  6. Hot fuel gas dedusting after sorbent-based gas cleaning

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Advanced power generation technologies, such as Air Blown Gasification Cycle (ABGC), require gas cleaning at high temperatures in order to meet environmental standards and to achieve high thermal efficiencies. The primary hot gas filtration process, which removes particulates from the cooled raw fuel gas at up to 600{degree}C is the first stage of gas cleaning prior to desulphurization and ammonia removal processes. The dust concentration in the fuel gas downstream of the sorbent processes would be much lower than for the hot gas filtration stage and would have a lower sulphur content and possibly reduced chlorine concentration. The main aim of this project is to define the requirements for a hot gas filter for dedusting fuel gas under these conditions, and to identify a substantially simpler and more cost effective solution using ceramic or metal barrier filters.

  7. Large-scale biodiesel production using flue gas from coal-fired power plants with Nannochloropsis microalgal biomass in open raceway ponds.

    Science.gov (United States)

    Zhu, Baohua; Sun, Faqiang; Yang, Miao; Lu, Lin; Yang, Guanpin; Pan, Kehou

    2014-12-01

    The potential use of microalgal biomass as a biofuel source has raised broad interest. Highly effective and economically feasible biomass generating techniques are essential to realize such potential. Flue gas from coal-fired power plants may serve as an inexpensive carbon source for microalgal culture, and it may also facilitate improvement of the environment once the gas is fixed in biomass. In this study, three strains of the genus Nannochloropsis (4-38, KA2 and 75B1) survived this type of culture and bloomed using flue gas from coal-fired power plants in 8000-L open raceway ponds. Lower temperatures and solar irradiation reduced the biomass yield and lipid productivities of these strains. Strain 4-38 performed better than the other two as it contained higher amounts of triacylglycerols and fatty acids, which are used for biodiesel production. Further optimization of the application of flue gas to microalgal culture should be undertaken. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Analysis of Flue Gas Desulfurization (FGD) Processes for Potential Use on Army Coal-Fired Boilers

    Science.gov (United States)

    1980-09-01

    SYSTEMS ALKALI- LIME/LIMESTONE AMMONIA SCRUBBING LIME OR LIMESTONE HC SCRUBBER INJECTION DRY SYSTEMS NAHCOLITE INJECTION BOILER INJECTION...requirements, and flexibility. Single-alkali flue gas scrubbers are gas-Hquid contacting devices that use the chemical reactions between soluble alkali... scrubbers are gas-liquid contacting devices that use the chemical reactions between limestone (mostly CaC03) and SOp to remove the oxides of sulfur from

  9. Flue gas conditioning today

    Energy Technology Data Exchange (ETDEWEB)

    Southam, B.J.; Coe, E.L. Jr. [Wahlco Engineering International Ltd., Santa Ana, CA (United States)

    1995-12-01

    Many relatively small electrostatic precipitators (ESP`s) exist which collect fly ash at remarkably high efficiencies and have been tested consistently at correspondingly high migration velocities. But the majority of the world`s coal supplies produce ashes which are collected at much lower migration velocities for a given efficiency and therefore require correspondingly large specific collection areas to achieve acceptable results. Early trials of flue gas conditioning (FGC) showed benefits in maximizing ESP performance and minimizing expense which justified continued experimentation. Trials of several dozen ways of doing it wrong eventually developed a set of reliable rules for doing it right. One result is that the use of sulfur trioxide (SO{sub 3}) for adjustment of the resistivity of fly ash from low sulfur coal has been widely applied and has become an automatically accepted part of the option of burning low sulfur coal for compliance with the Clean Air Act of l990 in the U.S.A. Currently, over 100,000 MW of generating capacity is using FGC, and it is estimated that approximately 45,800 MW will utilize coal-switching with FGC for Clean Air Act emission compliance. Guarantees that this equipment will be available to operate at least 98 percent of the time it is called upon are routinely fulfilled.

  10. Flue gas cleanup using the Moving-Bed Copper Oxide Process

    Energy Technology Data Exchange (ETDEWEB)

    Pennline, Henry W; Hoffman, James S

    2013-10-01

    The use of copper oxide on a support had been envisioned as a gas cleanup technique to remove sulfur dioxide (SO{sub 2}) and nitric oxides (NO{sub x}) from flue gas produced by the combustion of coal for electric power generation. In general, dry, regenerable flue gas cleanup techniques that use a sorbent can have various advantages, such as simultaneous removal of pollutants, production of a salable by-product, and low costs when compared to commercially available wet scrubbing technology. Due to the temperature of reaction, the placement of the process into an advanced power system could actually increase the thermal efficiency of the plant. The Moving-Bed Copper Oxide Process is capable of simultaneously removing sulfur oxides and nitric oxides within the reactor system. In this regenerable sorbent technique, the use of the copper oxide sorbent was originally in a fluidized bed, but the more recent effort developed the use of the sorbent in a moving-bed reactor design. A pilot facility or life-cycle test system was constructed so that an integrated testing of the sorbent over absorption/regeneration cycles could be conducted. A parametric study of the total process was then performed where all process steps, including absorption and regeneration, were continuously operated and experimentally evaluated. The parametric effects, including absorption temperature, sorbent and gas residence times, inlet SO{sub 2} and NO{sub x} concentration, and flyash loadings, on removal efficiencies and overall operational performance were determined. Although some of the research results have not been previously published because of previous collaborative restrictions, a summary of these past findings is presented in this communication. Additionally, the potential use of the process for criteria pollutant removal in oxy-firing of fossil fuel for carbon sequestration purposes is discussed.

  11. Hot gas cleaning, a targeted project

    Energy Technology Data Exchange (ETDEWEB)

    Romey, I. [University of Essen, Essen (Germany)

    1998-11-01

    Advanced hot gas cleaning systems will play a key role in future integrated combined cycle technologies. IGCC demonstration plants in operation or under construction are at present equipped with conventional wet gas scrubbing and cleaning systems. Feasibility studies for those IGCC plants have shown that the total efficiency of the processes can be improved using hot gas cleaning systems. However, this technology has not been developed and tested at a technical scale. Six well-known European industrial companies and research centres jointly worked together since January 1996 on a Targeted Project `Hot Gas Cleaning` to investigate and develop new hot gas cleaning systems for advanced clean coal power generation processes. In addition project work on chemical analysis and modelling was carried out in universities in England and Germany. The latest main findings were presented at the workshop. The main project aims are summarised as follows: to increase efficiency of advanced power generation processes; to obtain a reduction of alkalis and environmental emissions e.g. SO{sub 2}, NO{sub x}, CO{sub 2} and dust; and to develop the design basis for future industrial plants based on long-term operation of laboratory, pilot and demo-plants. To cover a range of possible process routes for future hot gas cleaning systems the following research programme is under investigation: removal of trace elements by different commercial and self developed sorbents; gas separation by membranes; separation of gas turbine relevant pollutants by hot filter dust and; H{sub 2}S removal and gas dedusting at high temperatures. 13 figs.

  12. Calcium and organic matter removal by carbonation process with waste incineration flue gas towards improvement of leachate biotreatment performance.

    Science.gov (United States)

    Zhang, Cheng; Zhu, Xuedong; Wu, Liang; Li, Qingtao; Liu, Jianyong; Qian, Guangren

    2017-09-01

    Municipal solid wastes incineration (MSWI) flue gas was employed as the carbon source for in-situ calcium removal from MSWI leachate. Calcium removal efficiency was 95-97% with pH of 10.0-11.0 over 100min of flue gas aeration, with both bound Ca and free Ca being removed effectively. The fluorescence intensity of tryptophan, protein-like and humic acid-like compounds increased after carbonation process. The decrease of bound Ca with the increase of precipitate indicated that calcium was mainly converted to calcium carbonate precipitate. It suggested that the interaction between dissolved organic matter and Ca 2+ was weakened. Moreover, 10-16% of chemical oxygen demand removal and the decrease of ultraviolet absorption at 254nm indicated that some organics, especially aromatic compound decreased via adsorption onto the surface of calcium carbonate. The results indicate that introduce of waste incineration flue gas could be a feasible way for calcium removal from leachate. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Evaluation of Synthetic Gypsum Recovered via Wet Flue-Gas Desulfurization from Electric Power Plants for Use in Foundries

    Directory of Open Access Journals (Sweden)

    R. Biernacki

    2012-09-01

    Full Text Available This article investigates possible use of waste gypsum (synthetic, recovered via flue-gas desulfurization from coal-fired electric powerplants, in foundries. Energy sector, which in Eastern Europe is mostly composed from coal-fired electric power plants, is one of the largestproducers of sulfur dioxide (SO2.In order to protect the environment and reduce the amount of pollution flue-gas desulfurization (FGD is used to remove SO2 fromexhaust flue gases of fossil-fuel power plants. As a result of this process gypsum waste is produced that can be used in practicalapplications.Strength and permeability tests have been made and also in-depth analysis of energy consumption of production process to investigateways of preparing the synthetic gypsum for casting moulds application. This paper also assesses the chemical composition, strength andpermeability of moulds made with synthetic gypsum, in comparison with moulds made with traditional GoldStar XL gypsum and withceramic molds. Moreover examination of structure of synthetic gypsum, the investigations on derivatograph and calculations of energyconsumption during production process of synthetic gypsum in wet flue-gas desulfurization were made.After analysis of gathered data it’s possible to conclude that synthetic gypsum can be used as a material for casting mould. There is nosignificant decrease in key properties, and on the other hand there is many additional benefits including low energy consumption,decreased cost, and decreased environmental impact.

  14. Multi-component removal in flue gas by aqua ammonia

    Science.gov (United States)

    Yeh, James T [Bethel Park, PA; Pennline, Henry W [Bethel Park, PA

    2007-08-14

    A new method for the removal of environmental compounds from gaseous streams, in particular, flue gas streams. The new method involves first oxidizing some or all of the acid anhydrides contained in the gas stream such as sulfur dioxide (SO.sub.2) and nitric oxide (NO) and nitrous oxide (N.sub.2O) to sulfur trioxide (SO.sub.3) and nitrogen dioxide (NO.sub.2). The gas stream is subsequently treated with aqua ammonia or ammonium hydroxide which captures the compounds via chemical absorption through acid-base or neutralization reactions. The products of the reactions can be collected as slurries, dewatered, and dried for use as fertilizers, or once the slurries have been dewatered, used directly as fertilizers. The ammonium hydroxide can be regenerated and recycled for use via thermal decomposition of ammonium bicarbonate, one of the products formed. There are alternative embodiments which entail stoichiometric scrubbing of nitrogen oxides and sulfur oxides with subsequent separate scrubbing of carbon dioxide.

  15. The hot gas cleaning with multifunctional sorbent technique at 1-20 bar pressure; Kaasujen kuumapuhdistus multifunktionaalisella sorbenttitekniikalla 1-20 bar:n paineessa

    Energy Technology Data Exchange (ETDEWEB)

    Jaanu, K.; Orjala, M.; Paakkinen, K.; Rantanen, J. [VTT Energy, Espoo (Finland)

    1996-12-01

    The aim of the research was to study the simultaneous hot gas cleanup of alkali metals and selected heavy metals under pressure of 1-20 bar using multifunctional sorbent technology, to investigate effects of it on sulfur and nitrogen emissions and to improve the total efficiency of the hot gas cleanup method by reducing the concentrations of harmful components to the level required by the gas turbines. The research has started in the year 1993. The optimization of the test facility at 900 deg C and 20 bar has been accomplished, as targeted. The main topics have been the alkali metals. The main targets of the year 1994 was to concentrate on the research of sorbent effectiveness to remove the impurities like alkalies etc. from the flue gas. Furthermore researches on kinetics and mechanisms were started. The results showed that the developed multifunctional sorbent are highly effective to remove alkalies from the flue gas. Also a mechanism for alkali and lead sorption was proposed. The main topics for 1995 were scheduled to be the completion of the kinetic and mechanical studies and the modelling and the estimation of the data for the pilot scale unit. The kinetic data for one sorbent has been completed and a model for that has also been developed. The measured and calculated results are indicating that the developed multifunctional sorption process is highly effective to remove alkalies and heavy metals such as lead and cadmium from high-temperature combustion gases. The tests are carried out mainly using the pressurized entrained flow reactor of VTT Energy, located in Jyvaeskylae, and in the university of Arizona, where the tests are conducted under atmospheric pressure. Some comparisons of the results might be made with those of Aabo Akademi during the future modelling. 3. The results are applied to purification of the hot gases in boilers, power and process industry. (Abstract Truncated)

  16. Wet Flue Gas Desulfurization Using a New O-Element Design Which Replaces the Venturi Scrubber

    OpenAIRE

    P. Lestinsky; D. Jecha; V. Brummer; P. Stehlik

    2015-01-01

    Scrubbing by a liquid spraying is one of the most effective processes used for removal of fine particles and soluble gas pollutants (such as SO2, HCl, HF) from the flue gas. There are many configurations of scrubbers designed to provide contact between the liquid and gas stream for effectively capturing particles or soluble gas pollutants, such as spray plates, packed bed towers, jet scrubbers, cyclones, vortex and venturi scrubbers. The primary function of venturi scrubb...

  17. Crystallisation of Gypsum and Prevention of Foaming in Wet Flue Gas Desulphurisation (FGD) Plants

    DEFF Research Database (Denmark)

    Hansen, Brian Brun

    The aim of this project is to investigate two operational problems, which have been experienced during wet flue gas desulphurisation (FGD) operation, i.e. poor gypsum dewatering properties and foaming. The results of this work can be used for the optimization of wet FGD-plants in terms of reliabi......The aim of this project is to investigate two operational problems, which have been experienced during wet flue gas desulphurisation (FGD) operation, i.e. poor gypsum dewatering properties and foaming. The results of this work can be used for the optimization of wet FGD-plants in terms....... Experiments in a falling film wet FGD pilot plant have shown a strong non-linear behaviour (in a ln(n(l)) vs. l plot) at the lower end of the particle size range, compared to the well-known linear “mixed suspension mixed product removal (MSMPR)” model. A transient population balance model, fitted...

  18. HOT GAS HALOS IN EARLY-TYPE FIELD GALAXIES

    International Nuclear Information System (INIS)

    Mulchaey, John S.; Jeltema, Tesla E.

    2010-01-01

    We use Chandra and XMM-Newton to study the hot gas content in a sample of field early-type galaxies. We find that the L X -L K relationship is steeper for field galaxies than for comparable galaxies in groups and clusters. The low hot gas content of field galaxies with L K ∼ * suggests that internal processes such as supernovae-driven winds or active galactic nucleus feedback expel hot gas from low-mass galaxies. Such mechanisms may be less effective in groups and clusters where the presence of an intragroup or intracluster medium can confine outflowing material. In addition, galaxies in groups and clusters may be able to accrete gas from the ambient medium. While there is a population of L K ∼ * galaxies in groups and clusters that retain hot gas halos, some galaxies in these rich environments, including brighter galaxies, are largely devoid of hot gas. In these cases, the hot gas halos have likely been removed via ram pressure stripping. This suggests a very complex interplay between the intragroup/intracluster medium and hot gas halos of galaxies in rich environments, with the ambient medium helping to confine or even enhance the halos in some cases and acting to remove gas in others. In contrast, the hot gas content of more isolated galaxies is largely a function of the mass of the galaxy, with more massive galaxies able to maintain their halos, while in lower mass systems the hot gas escapes in outflowing winds.

  19. Characterization and Regeneration of Pt-Catalysts Deactivated in Municipal Waste Flue Gas

    DEFF Research Database (Denmark)

    Rasmussen, Søren Birk; Kustov, Arkadii; Due-Hansen, Johannes

    2006-01-01

    Severe deactivation was observed for industrially aged catalysts used in waste incineration plants and tested in lab-scale. Possible compounds that cause deactivation of these Pt-based CO oxidation catalysts have been studied. Kinetic observations of industrial and model catalysts showed...... that siloxanes were the most severe catalyst poisons, although acidic sulfur compounds also caused deactivation. Furthermore, a method for on-site regeneration without shutdown of the catalytic flue gas cleaning system has been developed, i.e. an addition of H-2/N-2 gas to the off-gas can completely restore...... the activity of the deactivated catalysts. (c) 2006 Elsevier B.V. All rights reserved....

  20. Experimental Investigation and Modelling of a Wet Flue Gas Desulphurisation Pilot Plant

    DEFF Research Database (Denmark)

    Kiil, Søren; Michelsen, Michael Locht; Dam-Johansen, Kim

    1998-01-01

    A detailed model for a wet flue gas desulphurisation (FGD) pilot plant, based on the packed tower concept, has been developed. All important rate determining steps, absorption of SO2, oxidation of HSO3-, dissolution of limestone, and crystallisation of gypsum were included. Population balance...... equations, governing the description of particle size distributions of limestone in the plant, were derived. Model predictions were compared to experimental data such as gas phase concentration profiles of SO2, slurry pH-profiles, solids content of the slurry, liquid phase concentrations, and residual...

  1. A hybrid plasma-chemical system for high-NOx flue gas treatment

    Science.gov (United States)

    Chmielewski, Andrzej G.; Zwolińska, Ewa; Licki, Janusz; Sun, Yongxia; Zimek, Zbigniew; Bułka, Sylwester

    2018-03-01

    The reduction of high concentrations of NOx and SO2 from simulated flue gas has been studied. Our aim was to optimise energy consumption for NOx and SO2 removal from off-gases from a diesel generator using heavy fuel oil. A hybrid process: electron beam (EB) plasma and wet scrubber has been applied. A much higher efficiency of NOx and SO2 removal was achieved in comparison to dry, ammonia free, electron beam flue gas treatment (EBFGT). A recorded removal from a concentration of 1500 ppm NOx reached 49% at a low dose of 6.5 kGy, while only 2% NOx was removed at the same dose if EB only was applied. For SO2, removal efficiency at a dose of 6.5 kGy increased from 15% (EB only) to 84% when sea water was used as a wet scrubber agent for 700 ppm SO2. The results of this study indicate that EB combined with wet scrubber is a very promising technology to be applied for removal of high concentrations of NOx and SO2 emitted from diesel engines operated e.g. on cargo ships, which are the main sources of SO2 and NOx pollution along their navigation routes.

  2. CO2 Capture by Cold Membrane Operation with Actual Power Plant Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Chaubey, Trapti [American Air Liquide Inc., Houston, TX (United States); Kulkarni, Sudhir [American Air Liquide Inc., Houston, TX (United States); Hasse, David [American Air Liquide Inc., Houston, TX (United States); Augustine, Alex [American Air Liquide Inc., Houston, TX (United States)

    2017-07-28

    The main objective of the project was to develop a post-combustion CO2 capture process based on the hybrid cold temperature membrane operation. The CO2 in the flue gas from coal fired power plant is pre-concentrated to >60% CO2 in the first stage membrane operation followed by further liquefaction of permeate stream to achieve >99% CO2 purity. The aim of the project was based on DOE program goal of 90% CO2 capture with >95% CO2 purity from Pulverized Coal (PC) fired power plants with $40/tonne of carbon capture cost by 2025. The project moves the technology from TRL 4 to TRL 5. The project involved optimization of Air Liquide commercial 12” PI-1 bundle to improve the bundle productivity by >30% compared to the previous baseline (DE-FE0004278) using computational fluid dynamics (CFD) modeling and bundle testing with synthetic flue gas at 0.1 MWe bench scale skid located at Delaware Research and Technology Center (DRTC). In parallel, the next generation polyimide based novel PI-2 membrane was developed with 10 times CO2 permeance compared to the commercial PI-1 membrane. The novel PI-2 membrane was scaled from mini-permeator to 1” permeator and 1” bundle for testing. Bundle development was conducted with a Development Spin Unit (DSU) installed at MEDAL. Air Liquide’s cold membrane technology was demonstrated with real coal fired flue gas at the National Carbon Capture Center (NCCC) with a 0.3 MWe field-test unit (FTU). The FTU was designed to incorporate testing of two PI-1 commercial membrane bundles (12” or 6” diameter) in parallel or series. A slip stream was sent to the next generation PI-2 membrane for testing with real flue gas. The system exceeded performance targets with stable PI-1 membrane operation for over 500 hours of single bundle, steady state testing. The 12” PI-1 bundle exceeded the productivity target by achieving ~600 Nm3/hr, where the target was set at ~455

  3. Handbook - Status assessment of polymeric materials in flue gas cleaning systems; Handbok - Statusbedoemning av polymera material i roekgassystem

    Energy Technology Data Exchange (ETDEWEB)

    Roemhild, Stefanie

    2011-01-15

    In today's flue gas cleaning systems with advanced energy recovery systems and improved flue gas cleaning, the use of polymeric materials has continuously increased in applications where the flue gas environment is to corrosive to be handled with metallic materials. Typical polymeric materials used are fibre reinforced plastics (FRP), glassflake-filled linings, polypropylene (PP) and fluoropolymers. Demands on increased profitability and efficiency at incineration plants involve that also polymeric materials have to face more demanding environments with increased temperature, temperature changes, changes in fuel composition and therewith fluegas composition and longer service intervals. The knowledge on how polymeric materials perform in general and how these service conditions influence them, is, however, poor and continuous status assessment is therefore necessary. The overall aim of this project has been to assess simple techniques for status assessment of polymeric materials in flue gas cleaning equipment and to perform an inventory of present experience and knowledge on the use of polymeric materials. The project consisted of an inventory of present experience, analysis of material from shut-down plants and plants still in service, field testing in a plant adding sulphur during combustion and the assessment of different non-destructive testing (NDT) methods by laboratory experiments. The results of the project are summarised in the form of a handbook which in the first place addresses plant owners and maintenance staff at incineration plants and within the pulp and paper industry. In the introductory chapter typical polymeric materials (FRP, flake linings, PP and fluoropolymers) used in flue gas cleaning equipment are described as well as the occurring corrosion mechanisms. The inventory of process equipment is divided into sections about scrubbers, flue gas ducts, stacks, internals and other equipment such as storage tanks. Typical damages are

  4. Flue gas desulfurization gypsum: Its effectiveness as an alternative bedding material for broiler production

    Science.gov (United States)

    Flue gas desulfurization gypsum (FGDG) may be a viable low-cost alternative bedding material for broiler production. In order to evaluate FGD gypsum’s viability, three consecutive trials were conducted to determine its influence on live performance (body weight, feed consumption, feed efficiency, an...

  5. Subsequent flue gas desulfurization of coal-fired power plant units

    International Nuclear Information System (INIS)

    Willibal, U.; Braun, Gy.

    1998-01-01

    The presently operating coal-fired power plant in Hungary do not satisfy the pollution criteria prescribed by the European Union norms. The main polluting agent is the sulfur dioxide emitted by some of the power plants in Hungary in quantities over the limit standards. The power plant units that are in good operating state could be made competitive by using subsequent desulfurization measures. Various flue gas desulfurization technologies are presented through examples that can be applied to existing coal-fired power plants. (R.P.)

  6. Developing low-cost carbon-based sorbents for Hg capture from flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Perry, R.; Lakatos, J.; Snape, C.E.; Sun, C. [University of Nottingham, Nottingham (United Kingdom). Nottingham Fuel and Energy Centre

    2005-07-01

    To help reduce the cost of Hg capture from flue gas a number of low-cost carbons are being investigated, including activated tyre char and PFA carbon, in conjunction with some of the pre-treatments that have been found to be effective for commercial actived carbons. Experimental conditions for screening the sorbents have been selected to determine breakthrough capacities rapidly. The unactivated carbons have low breakthrough capacities under the test conditions employed (around 0.1 mg g{sup -1}) but these improve upon steam activation (around 0.25 mg g{sup -1}) but are still lower than those of non-impregnated commercial activated carbons (around 0.4-0.7 mg g{sup -1}), due to their lower surface areas. Comparable improvements to the commercial carbons have been achieved for impregnation treatments, including sulfur and bromine. However, certain gasification chars do have much higher breakthrough capacities than commercial carbons used for flue gas injection. Manganese oxide impregnation with low concentration is particularly effective for the activated and unactivated carbons giving breakthrough capacities comparable to the commercial carbons. Pointers for further increasing breakthrough and equilibrium capacities for carbon-based sorbents are discussed. 7 refs., 1 fig., 3 tabs.

  7. Depressurization test on hot gas duct

    International Nuclear Information System (INIS)

    Tanihira, Masanori; Kunitomi; Kazuhiko; Inagaki, Yoshiyuki; Miyamoto, Yoshiaki; Sato, Yutaka.

    1989-05-01

    To study the integrity of internal structures and the characteristics in a hot gas duct under the rapid depressurization accident, depressurization tests have been carried out using a test apparatus installed the hot gas duct with the same size and the same structures as that of the High Temperature Engineering Test Reactor (HTTR). The tests have been performed with three parameters: depressurization rate (0.14-3.08 MPa/s) determined by orifice diameter, area of the open space at the slide joint (11.9-2036 mm 2 ), and initial pressure (1.0-4.0 MPa) filled up in a pressure vessel, by using nitrogen gas and helium gas. The maximum pressure difference applied on the internal structures of the hot gas duct was 2.69 MPa on the liner tube and 0.45 MPa on the separating plate. After all tests were completed, the hot gas duct which was used in the tests was disassembled. Inspection revealed that there were no failure and no deformation on the internal structures such as separating plates, insulation layers, a liner tube and a pressure tube. (author)

  8. CFD analysis of a rotary kiln using for plaster production and discussion of the effects of flue gas recirculation application

    Science.gov (United States)

    Gürtürk, Mert; Oztop, Hakan F.; Pambudi, Nugroho Agung

    2018-04-01

    In this study, the CFD analysis of the rotary kiln is carried out for examining effects of various parameters on energy consumption and efficiency of the rotary kiln. The flue gas recirculation using in many applications is a useful method for combusting of fuel unburned in the flue gas. Also, effects of flue gas recirculation on the combusting of fuel, operating temperature and efficiency of the rotary kiln are discussed in this study. The rotary kiln, which is considered in this study, is used in plaster plant. Two different CFD models were created and these models are compared according to many parameters such as temperature distribution, mixture fraction, the mass fraction of O2, CO, CO and CH4 in the combustion chamber. It is found that the plaster plant has a great potential for an increase in energy efficiency. Results obtained for producers of rotary kiln and burner will be useful for determining better design parameters.

  9. Potential Agricultural Uses of Flue Gas Desulfurization Gypsum in the Northern Great Plains

    Energy Technology Data Exchange (ETDEWEB)

    DeSutter, T.M.; Cihacek, L.J. [North Dakota State University, Fargo, ND (United States). Department of Soil Science

    2009-07-15

    Flue gas desulfurization gypsum (FGDG) is a byproduct from the combustion of coal for electrical energy production. Currently, FGDG is being produced by 15 electrical generating stations in Alabama, Florida, Indiana, Iowa, Kentucky, Ohio, North Carolina, South Carolina, Tennessee, Texas, and Wisconsin. Much of this byproduct is used in the manufacturing of wallboard. The National Network for Use of FGDG in Agriculture was initiated to explore alternative uses of this byproduct. In the northern Great Plains (North Dakota, South Dakota, and Montana), FGDG has the potential to be used as a Ca or S fertilizer, as an acid soil ameliorant, and for reclaiming or mitigating sodium-affected soils. Greater than 1.4 million Mg of FGDG could initially be used in these states for these purposes. Flue gas desulfurization gypsum can be an agriculturally important resource for helping to increase the usefulness of problem soils and to increase crop and rangeland production. Conducting beneficial use audits would increase the public awareness of this product and help identify to coal combustion electrical generating stations the agriculturally beneficial outlets for this byproduct.

  10. Microalgae Production from Power Plant Flue Gas: Environmental Implications on a Life Cycle Basis

    Energy Technology Data Exchange (ETDEWEB)

    Kadam, K. L.

    2001-06-22

    Power-plant flue gas can serve as a source of CO{sub 2} for microalgae cultivation, and the algae can be cofired with coal. This life cycle assessment (LCA) compared the environmental impacts of electricity production via coal firing versus coal/algae cofiring. The LCA results demonstrated lower net values for the algae cofiring scenario for the following using the direct injection process (in which the flue gas is directly transported to the algae ponds): SOx, NOx, particulates, carbon dioxide, methane, and fossil energy consumption. Carbon monoxide, hydrocarbons emissions were statistically unchanged. Lower values for the algae cofiring scenario, when compared to the burning scenario, were observed for greenhouse potential and air acidification potential. However, impact assessment for depletion of natural resources and eutrophication potential showed much higher values. This LCA gives us an overall picture of impacts across different environmental boundaries, and hence, can help in the decision-making process for implementation of the algae scenario.

  11. Pilot-scale multistage membrane process for the separation of CO2 from LNG-fired flue gas

    KAUST Repository

    Choi, Seung Hak

    2013-06-01

    In this study, a multistage pilot-scale membrane plant was constructed and operated for the separation of CO2 from Liquefied Natural Gas (LNG)-fired boiler flue gas of 1000 Nm3/day. The target purity and recovery of CO2 were 99 vol.% and 90%, respectively. For this purpose, asymmetric polyethersulfone (PES) hollow fibers membranes has been developed in our previous work and has evaluated the effects of operating pressure and feed concentration of CO2 on separation performance. The operating and permeation data obtained were also analyzed in relation with the numerical simulation data using countercurrent flow model. Based on these results, in this study, four-staged membrane process including dehumidification process has been designed, installed, and operated to demonstrate the feasibility of multistage membrane systems for removing CO2 from flue gases. The operation results using this plant were compared to the numerical simulation results on multistage membrane process. The experimental results matched well with the numerical simulation data. The concentration and the recovery of CO2 in the permeate stream of final stage were ranged from 95-99 vol.% and 70-95%, respectively, depending on the operating conditions. This study demonstrated the applicability of the membrane-based pilot plant for CO2 recovery from flue gas. © 2013 Elsevier B.V. All rights reserved.

  12. Materials in flue gas condensation plants. Stage 2; Materialval vid roekgaskondensering. Etapp 2

    Energy Technology Data Exchange (ETDEWEB)

    Nordling, Magnus; Bergman, Gunnar; Baeck, Gustaf; Jacobsson, Karin; Pahverk, Helen; Roemhild, Stefanie

    2004-12-01

    The corrosion resistance of some metallic and polymeric materials has been investigated in the flue gas scrubbers/condensers in the power plants at Igelsta using waste wood and Brista using bio fuel in the boilers. The materials were exposed inside the inlet part of the condenser and inside the flue gas duct after the condenser. In Brista, the polymeric materials were also exposed to the hot flue gases inside the duct before the condenser. The temperature of the gases before and after the condenser in Brista was 140 deg C and 50-60 deg C, respectively. In Igelsta, the flue gas temperature after the condenser was 45 deg C. The metallic coupons in the condenser were located in the spray-zone, both in Igelsta and Brista. That was true also for the polymeric material in Brista. In both plants, the wash-solution had a pH of 7-8, a temperature of 30 deg C, and a low content of chloride. The metallic materials investigated were stainless steels of the following grades: 17-12-2.5, 2205, SAF2507 and 254SMO. The major part of the polymeric materials investigated consisted of FRP laminates, which were made with different combinations of resin type of surface veil and type of chopped strand mat (CSM). Laminates with a new type of vinyl ester resin, Atlac E-Nova FW 1045, a new type of a stress-corrosion-resistant glass-fibre called Arcotex, and two types of surface reinforcement of carbon fibre have been compared to laminates of common type. Laminates with a special reinforcement of the type 3-D fabric were also included as well as five polypropylene materials (PP) with varying degree of stabilisation, two glass-flake materials applied on carbon steel and a butyl rubber. The corrosion resistance of the materials was evaluated after seven a months exposure at the different positions in the plants. The stainless steel materials were evaluated with respect to uniform corrosion, pitting and crevice attack. The corrosion resistance of the polymeric materials was evaluated with

  13. Effect of flue gas recirculation on heat transfer in a supercritical circulating fluidized bed combustor

    Directory of Open Access Journals (Sweden)

    Błaszczuk Artur

    2015-09-01

    Full Text Available This paper focuses on assessment of the effect of flue gas recirculation (FGR on heat transfer behavior in 1296t/h supercritical coal-fired circulating fluidized bed (CFB combustor. The performance test in supercritical CFB combustor with capacity 966 MWth was performed with the low level of flue gas recirculation rate 6.9% into furnace chamber, for 80% unit load at the bed pressure of 7.7 kPa and the ratio of secondary air to the primary air SA/PA = 0.33. Heat transfer behavior in a supercritical CFB furnace between the active heat transfer surfaces (membrane wall and superheater and bed material has been analyzed for Geldart B particle with Sauter mean diameters of 0.219 and 0.246 mm. Bed material used in the heat transfer experiments had particle density of 2700 kg/m3. A mechanistic heat transfer model based on cluster renewal approach was used in this work. A heat transfer analysis of CFB combustion system with detailed consideration of bed-to-wall heat transfer coefficient distributions along furnace height is investigated. Heat transfer data for FGR test were compared with the data obtained for representative conditions without recycled flue gases back to the furnace through star-up burners.

  14. SO{sub 2} removal from flue gas by activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Nilgun Karatepe; Ilkun Orbak; Reha Yavuz; Ayse Ozyuguran [Istanbul Technical University, Maslak-Istanbul (Turkey). Institute of Energy

    2007-07-01

    Adsorption of sulphur dioxide (SO{sub 2}) onto activated carbons prepared from Tuncbilek lignite with different methods was investigated. Experimental results showed that the adsorption temperature, initial SO{sub 2} concentration, particle size of the activated carbon and H{sub 2}O content in the flue gas had significantly effect on the amounts of SO{sub 2} adsorbed. Textural (BET surface area, micropore surface area, total pore volume, micropore volume and average pore size) characteristics of activated carbons also played an important role on adsorption of SO{sub 2}. 10 refs., 5 figs., 4 tabs.

  15. Mathematical modelling of flue gas tempered flames produced from pulverised coal fired with oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Breussin, A.; Weber, R.; Kamp, W.L. van de

    1997-10-01

    The combustion of pulverised coal in conventional utility boilers contributes significantly to global CO{sub 2} emissions. Because atmospheric air is used as the combustion medium, the exhaust gases of conventional pulverised coal fired utility boilers contain approximately 15 % CO{sub 2}. This relatively low concentration makes separating and recovering CO{sub 2} a very energy-intensive process. This process can be simplified if N{sub 2} is eliminated from the comburent before combustion by firing the pulverised coal with pure oxygen. However, this concept will result in very high flames temperatures. Flue gas recirculation can be used to moderate the flame temperature, whilst generating a flue gas with a CO{sub 2} concentration of 95 %. In this presentation, both experimental and modelling work will be described. The former deals with identifying the issues related to the combustion of pulverised coal in simulated turbine exhaust gas, particularly with respect to stability, burnout and pollutant emissions. The second part of this presentation describes mathematical modelling of type 2 as well as type 1 swirling pulverised coal flames. Future work will concentrate on high CO{sub 2} levels environments. (orig.)

  16. Advanced Flue Gas Desulfurization (AFGD) Demonstration Project. Technical progress report No. 15, July 1, 1993--September 30, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1994-08-01

    The goal of this project is to demonstrate that, by combining state-of-the-art technology, highly efficient plant operation and maintenance capabilities and by-product gypsum sales, significant reductions of SO{sub 2} emissions can be achieved at approximately one-half the life cycle cost of a conventional Flue Gas Desulfurization (FGD) system. Further, this emission reduction is achieved without generating solid waste and while minimizing liquid wastewater effluent. Basically, this project entails the design, construction and operation of a nominal 600 MWe AFGD facility to remove SO{sub 2} from coal-fired power plant flue gas at the Northern Indiana Public Service Company`s Bailly Generating Station.

  17. Degradation mechanisms of organic rubber and glass flake/vinyl ester linings in flue gas desulphurization plants

    Energy Technology Data Exchange (ETDEWEB)

    Weber, R [Allianz-Centre for Technology GmbH, Ismaning (Germany)

    1996-12-01

    In recent years, there have been reports in numerous publications about damage to rubber and glass flake coatings in flue gas desulphurization plants. The pattern of damage has been described and attempts have frequently been made to determine and explain the cause of the damage. Oxidation/hydrolytic changes were generally observed as the damage mechanisms. In addition, blistering occurs in both the chloroprene coatings in the absorbers and in the glass flake coatings in clean gas ducts. This blistering may be considered as the end of the useful life and leads to cost-intensive and time-intensive repair and restoration measures. The present state of knowledge suggests that the blistering is mainly due to osmotic processes preceded by permeation processes and with permeation processes superimposed on them. Among other things, the reports describe the permeation behaviour of water and other flue gas constituents; the blistering in chloroprene rubber coatings and glass flake coatings is explained by means of the knowledge gained. (au) 16 refs.

  18. Effects of water vapor on flue gas conditioning in the electric fields with corona discharge.

    Science.gov (United States)

    Liqiang, Qi; Yajuan, Zhang

    2013-07-15

    Sulfur dioxide (SO2) removal via pulsed discharge nonthermal plasma in the absence of ammonia was investigated to determine how electrostatic precipitators (ESPs) can effectively collect particulate matter less than 2.5μm in diameter from flue gas. SO2 removal increased as water vapor concentration increased. In a wet-type plasma reactor, directing a gas-phase discharge plasma toward the water film surface significantly enhanced the liquid-phase oxidation of HSO3(-) to SO4(2-). Comparisons of various absorbents revealed that the hydroxyl radical is a key factor in plasma-induced liquid-phase reactions. The resistivity, size distribution, and cohesive force of fly ash at different water vapor contents were measured using a Bahco centrifuge, which is a dust electrical resistivity test instrument, as well as a cohesive force test apparatus developed by the researchers. When water vapor content increased by 5%, fly ash resistivity in flue gas decreased by approximately two orders of magnitude, adhesive force and size increased, and specific surface area decreased. Therefore, ESP efficiency increased. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Integrating Waste Heat from CO2 Removal and Coal-Fired Flue Gas to Increase Plant Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Irvin, Nick [Southern Company Services, Inc., Birmingham, AL (United States); Kowalczyk, Joseph [Southern Company Services, Inc., Birmingham, AL (United States)

    2017-04-01

    In project DE-FE0007525, Southern Company Services demonstrated heat integration methods for the capture and sequestration of carbon dioxide produced from pulverized coal combustion. A waste heat recovery technology (termed High Efficiency System) from Mitsubishi Heavy Industries America was integrated into an existing 25-MW amine-based CO2 capture process (Kansai Mitsubishi Carbon Dioxide Recovery Process®1) at Southern Company’s Plant Barry to evaluate improvements in the energy performance of the pulverized coal plant and CO2 capture process. The heat integration system consists of two primary pieces of equipment: (1) the CO2 Cooler which uses product CO2 gas from the capture process to heat boiler condensate, and (2) the Flue Gas Cooler which uses air heater outlet flue gas to further heat boiler condensate. Both pieces of equipment were included in the pilot system. The pilot CO2 Cooler used waste heat from the 25-MW CO2 capture plant (but not always from product CO2 gas, as intended). The pilot Flue Gas Cooler used heat from a slipstream of flue gas taken from downstream of Plant Barry’s air heater. The pilot also included a 0.25-MW electrostatic precipitator. The 25-MW High Efficiency System operated for approximately six weeks over a four month time period in conjunction with the 25-MW CO2 capture facility at Plant Barry. Results from the program were used to evaluate the technical and economic feasibility of full-scale implementation of this technology. The test program quantified energy efficiency improvements to a host power plant that could be realized due to the High Efficiency System. Through the execution of this project, the team verified the integrated operation of the High Efficiency System and Kansai Mitsubishi Carbon Dioxide Recovery Process®. The ancillary benefits of the High Efficiency System were also quantified, including reduced water consumption

  20. Facile synthesis of triazine-triphenylamine-based microporous covalent polymer adsorbent for flue gas CO2 capture

    KAUST Repository

    Das, Swapan Kumar

    2017-07-17

    The sustainable capture and sequestration of CO2 from flue gas emission is an important and unavoidable challenge to control greenhouse gas release and climate change. In this report, we describe a triazine-triphenylamine-based microporous covalent organic polymer under mild synthetic conditions. 13C and 15N solid-state NMR and FTIR analyses confirm the linkage of the triazine and triphenylamine components in the porous polymer skeleton. The material is composed of spherical particles 1.0 to 2.0 μm in size and possesses a high surface area (1104 m2/g). The material exhibits superb chemical robustness under acidic and basic conditions and high thermal stability. Single-component gas adsorption exhibits an enhanced CO2 uptake of 3.12 mmol/g coupled with high sorption selectivity for CO2/N2 of 64 at 273 K and 1 bar, whereas the binary gas mixture breakthrough study using a model flue gas composition at 298 K shows a high CO2/N2 selectivity of 58. The enhanced performance is attributed to the high Lewis basicity of the framework, as it favors the interaction with CO2.

  1. Mixed microalgae consortia growth under higher concentration of CO2 from unfiltered coal fired flue gas: Fatty acid profiling and biodiesel production.

    Science.gov (United States)

    Aslam, Ambreen; Thomas-Hall, Skye R; Manzoor, Maleeha; Jabeen, Faiza; Iqbal, Munawar; Uz Zaman, Qamar; Schenk, Peer M; Asif Tahir, M

    2018-02-01

    Biodiesel is produced by transesterification of fatty acid methyl esters (FAME) from oleaginous microalgae feedstock. Biodiesel fuel properties were studied and compared with biodiesel standards. Qualitative analysis of FAME was done while cultivating mixed microalgae consortia under three concentrations of coal fired flue gas (1%, 3.0% and 5.5% CO 2 ). Under 1% CO 2 concentration (flue gas), the FAME content was 280.3 μg/mL, whereas the lipid content was 14.03 μg/mL/D (day). Both FAMEs and lipid contents were low at other CO 2 concentrations (3.0 and 5.5%). However, mixed consortia in the presence of phosphate buffer and flue gas (PB + FG) showed higher saturated fatty acids (SFA) (36.28%) and unsaturated fatty acids (UFA) (63.72%) versus 5.5% CO 2 concentration, which might be responsible for oxidative stability of biodiesel. Subsequently, higher cetane number (52) and low iodine value (136.3 gI 2 /100 g) biodiesel produced from mixed consortia (PB + FG) under 5.5% CO 2 along with 50 mM phosphate buffer were found in accordance with European (EN 14214) standard. Results revealed that phosphate buffer significantly enhanced the biodiesel quality, but reduced the FAME yield. This study intended to develop an integrated approach for significant improvement in biodiesel quality under surplus phosphorus by utilizing waste flue gas (as CO 2 source) using microalgae. The CO 2 sequestration from industrial flue gas not only reduced greenhouse gases, but may also ensure the sustainable and eco-benign production of biodiesel. Copyright © 2018. Published by Elsevier B.V.

  2. Chemical kinetics of flue gas cleaning by electron beam

    International Nuclear Information System (INIS)

    Maetzing, H.

    1989-02-01

    By electron beam treatment of flue gases, NO x and SO 2 are converted to nitric and sulfuric acids simultaneously. Upon ammonia addition, the corresponding salts are collected in solid state and can be sold as fertilizer. Both homogeneous gas phase reactions and physico-chemical aerosol dynamics are involved in product formation. These processes have been analyzed by model calculations. In part 1, the present report summarizes the model results and gives an account of the theoretical understanding of the EBDS process and its performance characteristics. Part 2 of this report gives a complete listing of the reactions used in the AGATE code. (orig.) [de

  3. Removal of fine particles in wet flue gas desulfurization system by heterogeneous condensation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, L.J.; Bao, J.J.; Yan, J.P.; Liu, J.H.; Song, S.J.; Fan, F.X. [Southeast University, Nanjing (China). School of Energy & Environment

    2010-01-01

    A novel process to remove fine particles with high efficiency by heterogeneous condensation in a wet flue gas desulfurization (WFGD) system is presented. A supersaturated vapor phase, necessary for condensational growth of fine particles, was achieved in the SO{sub 2} absorption zone and at the top of the wet FGD scrubber by adding steam in the gas inlet and above the scrubbing liquid inlet of the scrubber, respectively. The condensational grown droplets were then removed by the scrubbing liquid and a high-efficiency demister. The results show that the effectiveness of the WFGD system for removal of fine particles is related to the SO{sub 2} absorbent employed. When using CaCO{sub 3} and NH{sub 3} {center_dot} H{sub 2}O to remove SO{sub 2} from flue gas, the fine particle removal efficiencies are lower than those for Na2CO{sub 3} and water, and the morphology and elemental composition of fine particles are changed. This effect can be attributed to the formation of aerosol particles in the limestone and ammonia-based FGD processes. The performance of the WFGD system for removal of fine particles can be significantly improved for both steam addition cases, for which the removal efficiency increases with increasing amount of added steam. A high liquid to gas ratio is beneficial for efficient removal of fine particles by heterogeneous condensation of water vapor.

  4. Comparison of surface area changes during sulfation of sodium bicarbonate in a simulated flue gas with and without NO

    Energy Technology Data Exchange (ETDEWEB)

    Weil, A.E.; Keener, T.C.; Khang, S.J. [University of Cincinnati, Cincinnati, OH (United States). Department of Civil and Environmental Engineering

    1994-12-31

    Sodium bicarbonate has been identified as one of the most efficient reagents for flue gas desulfurization. Sodium bicarbonate has been demonstrated both in bench scale and large scale applications by a number of researchers globally. Scattered reporting of plume discolouration during demonstrations of sodium bicarbonate injection have been attributed to the formation of the reddish-brown gas NO{sub 2}. The purpose of this study was to compare the surface area changes of sodium bicarbonate during flue gas desulfurization as it relates to the formation of NO{sub 2} The results of this study have indicated an anomolous behaviour with respect to previously published data for non reactive gas environments. Notably it was shown that flue gas with NO lowered the surface area, most likely due to the formation of a low melting eutectic of sodium nitrate and sulphate. Nitrogen uptake was found to coincide with water evolution from decomposition. The results of this study more clearly define, on the microstructural level, the sulphur uptake mode. A unique laboratory differential fixed bed reactor was designed for this study. The setup included a quick quench zone to quench the reactions for data acquisition. BET surface area, IR elemental analysis, XRD crystallographic identification and SEM imaging were used to characterize microstructural mechanisms and to confirm reaction paths. 4 refs., 3 figs., 2 tabs.

  5. Detailed modelling of a flue-gas desulfurisation plant

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, A.; Fueyo, N.; Tomas, A. [University of Zaragoza, Zaragoza (Spain)

    2007-11-15

    This paper presents a CFD model for a flue-gas desulfurisation plant, and its application to an operating plant. The FGD plant is of the wet-scrubber type, with co-current and counter-current sections. The sorbent used is limestone, and, after cleaning the flue gases, the limestone slurry is collected in an oxidation tank for the production of gypsum. The model uses an Eulerian-Eulerian treatment of the multiphase flow in the absorber and the tank. The essential mass-transfer mechanisms (such as SO{sub 2} and O{sub 2} absorption and CO{sub 2} desorption) are accounted for, as are also the main chemical kinetics leading to the formation of gypsum. Given the different nature of the flow in the absorber and tank, two separate simulations are conducted for each of these domains, and the solutions are iteratively coupled through boundary conditions during the calculations. The model is applied to the FGD plant of the Teruel powerstation located in Andorra (Teruel, Spain). The powerstation is fired with a high-sulfur coal (up to 4.5 percent), and the FGD system has been designed for a desulfurisation capacity of 1.4 million N m{sup 3}/hr for a desulfurisation efficiency in excess of 90 percent. Validation of the model is conducted by comparison with available plant data for two design coals and two desulfurisation efficiencies. The model accuracy is reasonable, given the complexity of the aero/hydrodynamical and thermo-chemical phenomena involved.

  6. Installation of laboratory scale flue gas treatment system at ALURTRON, MINT

    International Nuclear Information System (INIS)

    Siti A'iasah Hashim; Khairul Zaman Dahlan; Zulkafli Ghazali; Khomsaton Abu Bakar, Ayub Muhamad

    2002-01-01

    A laboratory scale test rig to treat simulated flue gas using electron beam technology was installed at the Alurtron EB-irradiation center, MINT. The experiment test rig was proposed as a result of a feasibility studies conducted jointly by IAEA, MINT and TNB Research in 1997. The test rig system consisted of several components, among other, diesel generator, gas analyzers and spray cooler. The installation was completed and commissioned in October 2001. Results from the commissioning test runs and subsequent experimental work showed that the efficiency of the gas treatment is high. It was proven that electron beam technology might be applied in the treatment of air pollutants. This paper describes the design and work function of the individual major components as well as the full system function. Results from the initial experimental works are also presented. (Author)

  7. Flue gas carbon capture using hollow fiber membrane diffuser-separator

    Science.gov (United States)

    Ariono, D.; Chandranegara, A. S.; Widodo, S.; Khoiruddin; Wenten, I. G.

    2018-01-01

    In this work, CO2 removal from flue gas using membrane diffuser-separator was investigated. Hollow fiber polypropylene membrane was used as the diffuser while pure water was used as the absorbent. Separation performance of the membrane diffuser-separator as a function of CO2 concentration (6-28%-vol.) and flow rate (gas: 0.8-1.55 L.min-1 and liquid: 0.2-0.7 L.min-1) was investigated and optimized. It was found that CO2 removal was significantly affected by CO2 concentration in the feed gas. On the other hand, CO2 flux was more influenced by flow rates of liquid and gas rather than concentration. The optimized CO2 removal (64%) and flux (1 x 10-4 mol.m-2.s-1) were obtained at the highest gas flow rate (1.55 L.min-1), the lowest liquid flow rate (0.2 L.min-1), and 6.2%-vol. of CO2 concentration. Outlet gas of the membrane diffuser system tends to carry some water vapor, which is affected by gas and liquid flow rate. Meanwhile, in the steady-state operation of the separator, the gas bubbles generated by the membrane diffuser take a long time to be completely degassed from the liquid phase, thus a portion of gas stream was exiting separator through liquid outlet.

  8. Direct gas-solid carbonation kinetics of steel slag and the contribution to in situ sequestration of flue gas CO(2) in steel-making plants.

    Science.gov (United States)

    Tian, Sicong; Jiang, Jianguo; Chen, Xuejing; Yan, Feng; Li, Kaimin

    2013-12-01

    Direct gas-solid carbonation of steel slag under various operational conditions was investigated to determine the sequestration of the flue gas CO2 . X-ray diffraction analysis of steel slag revealed the existence of portlandite, which provided a maximum theoretical CO2 sequestration potential of 159.4 kg CO 2 tslag (-1) as calculated by the reference intensity ratio method. The carbonation reaction occurred through a fast kinetically controlled stage with an activation energy of 21.29 kJ mol(-1) , followed by 10(3) orders of magnitude slower diffusion-controlled stage with an activation energy of 49.54 kJ mol(-1) , which could be represented by a first-order reaction kinetic equation and the Ginstling equation, respectively. Temperature, CO2 concentration, and the presence of SO2 impacted on the carbonation conversion of steel slag through their direct and definite influence on the rate constants. Temperature was the most important factor influencing the direct gas-solid carbonation of steel slag in terms of both the carbonation conversion and reaction rate. CO2 concentration had a definite influence on the carbonation rate during the kinetically controlled stage, and the presence of SO2 at typical flue gas concentrations enhanced the direct gas-solid carbonation of steel slag. Carbonation conversions between 49.5 % and 55.5 % were achieved in a typical flue gas at 600 °C, with the maximum CO2 sequestration amount generating 88.5 kg CO 2 tslag (-1) . Direct gas-solid carbonation of steel slag showed a rapid CO2 sequestration rate, high CO2 sequestration amounts, low raw-material costs, and a large potential for waste heat utilization, which is promising for in situ carbon capture and sequestration in the steel industry. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Flue gas CO{sub 2} capture by a green liquid membrane

    Energy Technology Data Exchange (ETDEWEB)

    Michael C. Trachtenberg; Lihong Bao; Stefanie L. Goldman; David A. Smith; Xiaoqiu Wu [Carbozyme, Inc., Monmouth Junction, NJ (United States)

    2005-07-01

    We have designed, developed, modeled and tested several different membrane-based, facilitated transport carbonate / bicarbonate reactors (conjoint absorber-strippers) for the post-combustion extraction of CO{sub 2} from both air and flue gas. We have assessed separately the reactive chemistry, the reactor design and the process engineering. Facilitation is achieved by means of the most efficient CO{sub 2} conversion catalyst, the enzyme carbonic anhydrase. Experimental data mirror model predictions very closely. CO{sub 2} permeance value for 10% feed stream (balanced dry air) is 3.35E-8 mole/m{sup 2} s Pa, and the selectivity vs. N{sub 2} and vs. O{sub 2} were 250 and 150. The only moving elements in this design are the feed gas and the sweep gas streams. Gas separation is driven by partial pressure difference alone. As a consequence, this design is extremely energy efficient. 10 refs., 4 figs., 1 tab.

  10. COMPARISON OF WEST GERMAN AND U.S. FLUE GAS DESULFURIZATION AND SELECTIVE CATALYTIC REDUCTION COSTS

    Science.gov (United States)

    The report documents a comparison of the actual cost retrofitting flue gas desulfurization (FGD) and selective catalytic reduction (SCR) on Federal Republic of German (FRG) boilers to cost estimating procedures used in the U.S. to estimate the retrofit of these controls on U.S. b...

  11. Simultaneous adsorption of SO2 and NO from flue gas over mesoporous alumina.

    Science.gov (United States)

    Sun, Xin; Tang, Xiaolong; Yi, Honghong; Li, Kai; Ning, Ping; Huang, Bin; Wang, Fang; Yuan, Qin

    2015-01-01

    Mesoporous alumina (MA) with a higher ability to simultaneously remove SO2 and NO was prepared by the evaporation-induced self-assembly process. The adsorption capacities of MA are 1.79 and 0.702 mmol/g for SO2 and NO, respectively. The Brunauer-Emmett-Teller method was used to characterize the adsorbent. Simultaneous adsorption of SO2 and NO from flue gas over MA in different operating conditions had been studied in a fixed bed reactor. The effects of temperature, oxygen concentration and water vapour were investigated. The experimental results showed that the optimum temperature for MA to simultaneously remove SO2 and NO was 90°C. The simultaneous adsorption capacities of SO2 and NO could be enhanced by increasing O2 when its concentration was below 5%. The changes of simultaneous adsorption capacities were not obvious when O2 concentration was above 5%. The increase in relative humidity results in an increase after dropping of SO2 adsorption capacity, whereas the adsorption capacity of NO showed an opposite trend. The results suggest that MA is a great adsorbent for simultaneous removal of SO2 and NO from flue gas.

  12. A model for dry sodium bicarbonate duct injection flue gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Changfa Wu; Soon-Jai Khang; Tim C. Keener; Sang-Kwun Lee [University of Cincinnati, Cincinnati, OH (United States). Department of Chemical Engineering

    2004-03-01

    A mathematical model is developed for simulation of dry sodium bicarbonate (NaHCO{sub 3}) duct injection for the removal of sulfur dioxide (SO{sub 2}) in flue gases across a fabric filter (baghouse). The model employs parallel reaction kinetics and assumes that the sodium bicarbonate injection process can be separated into two stages. The first stage is a transport duct section where NaHCO{sub 3} particles are injected into the sulfur dioxide laden gas stream. The second stage is the fabric filter section where sodium sorbents are collected and behave as a variable depth fixed bed reactor. The process simulation for the efficiency of desulfurization in flue gas is performed and evaluated for a variety of operating conditions. It is found that the removal of SO{sub 2} within the duct section is small and negligible for most practical conditions, with a contribution normally less than 5% of total SO{sub 2} removal. The major removal of SO{sub 2} occurs across the filter cake, which accumulates the sorbent particles on the fabric filter. These particles are periodically disposed as the filter is cleaned. The major factors for the process are temperature, particle size and SO{sub 2} gas concentration for all operating conditions. At low temperatures, the removal of SO{sub 2} increases as temperature increases, but the removal decreases at higher temperatures due to the impact of the thermal decomposition reaction of NaHCO{sub 3} on SO{sub 2} removal. It was found that the temperature for the highest removal of SO{sub 2} is within the range of 127-150{sup o}C and the removal efficiency also depends on particle size.

  13. Experiments on the possible usage of liquid industrial wastes from a paint and lacquer factory for flue gas desulphurization

    Energy Technology Data Exchange (ETDEWEB)

    Trzepierczynska, I.; Lech-Brzyk, K. [Technical University of Wroclaw, Wroclaw (Poland). Inst. of Environment Protection Engineering

    1995-12-31

    In this paper, the complex solution of environment protection against flue gases (comprising sulphur dioxide) and alkaline industrial wastewater is provided. Industrial wastes from a paint and lacquer factory were examined and their usage for sulphur dioxide absorption was determined. The combined method of alkaline waste neutralization and flue gas desulphurization is proposed. The liquid wastes come from the POLIFARB SA plant in Wroclaw. 9 refs., 7 tabs.

  14. Effects of flue gas components on removal of elemental mercury over Ce–MnO_x/Ti-PILCs

    International Nuclear Information System (INIS)

    He, Chuan; Shen, Boxiong; Li, Fukuan

    2016-01-01

    Highlights: • Ce–MnO_x/Ti-PILC exhibited high Hg"0 removal activity. • SO_2 restrained Hg"0 oxidation and adsorption due to the formation of SO_4"2"−. • The formation of NH_3 to NH_4"+ restrained the Hg"0 adsorption and oxidation. - Abstract: The adsorption and oxidation of elemental mercury (Hg"0) under various flue gas components were investigated over a series of Ce–MnO_x/Ti-PILC catalysts, which were synthesized by an impregnation method. To discuss the mechanism, the catalysts were characterized by various techniques such as N_2 adsorption–desorption, scanning electron microscope (SEM), X-ray diffraction (XRD), Fourier transform infrared (FTIR) analysis and X-ray photoelectron spectroscopy (XPS). The results indicated that the presence of 500 ppm SO_2 in the flue gas significantly restrained the Hg"0 adsorption and oxidation over 6%Ce–6%MnO_x/Ti-PILC due to the formation of SO_4"2"− species. Hg"0 could be oxidized to HgCl_2 in the presence of HCl, because the Deacon process occurred. NO would react with active oxygen to form NO_2-containing species, which facilitated Hg"0 oxidation. While the presence of NO limited the Hg"0 adsorption on 6%Ce–6%MnO_x/Ti-PILC due to the competitive adsorption of NO with Hg"0. The addition of NH_3 in the flue gas significantly restrained Hg"0 adsorption and oxidation, because the formed NH_4"+ species covered the active adsorption sites on the surfaces, and further limited Hg"0 oxidation. However, when NO and NH_3 were simultaneously added into the flue gas, the Hg"0 oxidation efficiency of 6%Ce–6%MnO_x/Ti-PILC exhibited a relatively high value (72%) at 250 °C, which indicated the practicability to use Ce–MnO_x/Ti-PILC for Hg"0 removal under SCR conditions.

  15. Increasing draft capability for retrofit flue gas desulfurization systems

    International Nuclear Information System (INIS)

    Petersen, R.D.; Basel, B.E.; Mosier, R.J.

    1992-01-01

    The retrofit installation of flue gas desulfurization (FGD) systems results in significantly higher draft losses for existing generating stations. Consequently, the means for increasing draft capability must be included in many FGD retrofit projects. Consideration is given to several alternatives for increasing draft capability. Alternatives are developed for new induced draft (ID) fans to replace the existing ID fans and for new booster fans to supplement the existing ID fans. Both centrifugal and axial fans are evaluated, as are different means of fan volume control. Each alternative is evaluated on the basis of technical merit and economics. Presented are the development of fan alternatives and results of the technical and economic evaluations

  16. Simultaneous desulfurization and denitrification of flue gas by ·OH radicals produced from O2+ and water vapor in a duct.

    Science.gov (United States)

    Bai, Mindi; Zhang, Zhitao; Bai, Mindong

    2012-09-18

    In the present study, simultaneous flue gas desulfurization and denitrification are achieved with ·OH radicals generated from O(2)(+) reacting with water vapor in a duct. The O(2)(+) ions are generated by a strong ionization dielectric barrier discharge and then injected into the duct. Compared with conventional gas discharge treatment, the present method does not need a plasma reaction reactor, additional catalysts, reductants, or oxidants. The main recovered products are the liquids H(2)SO(4) and HNO(3), which can be used in many processes. Removal rates of 97% for NO and 82% for SO(2) are obtained under the following optimal experimental conditions: molar ratio of reactive oxygen species (O(2)(+), O(3)) to SO(2) and NO, 5; inlet flue gas temperature, 65 °C; reaction time, 0.94 s; and H(2)O volume fraction, 8%. Production of O(2)(+) and the plasma reaction mechanisms are discussed, and the recovered acid is characterized. The experimental results show that the present method performs better for denitrification than for desulfurization. Compared with conventional air discharge flue gas treatments, the present method has lower initial investment and operating costs, and the equipment is more compact.

  17. Regeneration of Pt-catalysts deactivated in municipal waste flue gas with H2/N2 and the effect of regeneration step on the SCR catalyst

    DEFF Research Database (Denmark)

    Due-Hansen, Johannes; Rasmussen, Søren Birk; Kustov, Arkadii

    Municipal waste flue gas was previously found to deactivate the Pt-based CO oxidation catalyst severely. In the specific case studied, siloxanes were found to cause the deactivation. An on-site method for complete regeneration of the catalyst activity was found without shutdown of the flue gas...... stream, i.e. by in situ treatment of the Pt-catalyst by reductive H2-gas. However, introduction of H2 gas in the gas stream could also affect other units in the tail pipe gas cleaning system. Of special interest here, is the effect of hydrogen gas on the performance of the deNOx + SCR catalytic process...

  18. A briefing paper for the status of the flue gas desulfurization system at Indianapolis Power ampersand Light Company Petersburg Station Units 1 and 2

    International Nuclear Information System (INIS)

    Rutledge, C.K.; Wolsiffer, S.R.; Gray, S.M.; Martin, J.E.; Wedig, C.P.

    1992-01-01

    This paper presents a brief description of the status of the retrofit wet limestone flue gas desulfurization system project at Indianapolis Power ampersand Light Company (IPL) Petersburg Units 1 and 2. This project was initiated by IPL in response to the Clean Air Act of 1990 and is intended to treat the flue gas from two base load units with a combined capacity of approximately 700 MW gross electrical output

  19. Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Carl Richardson; Katherine Dombrowski; Douglas Orr

    2006-12-31

    This project Final Report is submitted to the U.S. Department of Energy (DOE) as part of Cooperative Agreement DE-FC26-03NT41987, 'Sorbent Injection for Small ESP Mercury Control in Low Sulfur Eastern Bituminous Coal Flue Gas.' Sorbent injection technology is targeted as the primary mercury control process on plants burning low/medium sulfur bituminous coals equipped with ESP and ESP/FGD systems. About 70% of the ESPs used in the utility industry have SCAs less than 300 ft2/1000 acfm. Prior to this test program, previous sorbent injection tests had focused on large-SCA ESPs. This DOE-NETL program was designed to generate data to evaluate the performance and economic feasibility of sorbent injection for mercury control at power plants that fire bituminous coal and are configured with small-sized electrostatic precipitators and/or an ESP-flue gas desulfurization (FGD) configuration. EPRI and Southern Company were co-funders for the test program. Southern Company and Reliant Energy provided host sites for testing and technical input to the project. URS Group was the prime contractor to NETL. ADA-ES and Apogee Scientific Inc. were sub-contractors to URS and was responsible for all aspects of the sorbent injection systems design, installation and operation at the different host sites. Full-scale sorbent injection for mercury control was evaluated at three sites: Georgia Power's Plant Yates Units 1 and 2 [Georgia Power is a subsidiary of the Southern Company] and Reliant Energy's Shawville Unit 3. Georgia Power's Plant Yates Unit 1 has an existing small-SCA cold-side ESP followed by a Chiyoda CT-121 wet scrubber. Yates Unit 2 is also equipped with a small-SCA ESP and a dual flue gas conditioning system. Unit 2 has no SO2 control system. Shawville Unit 3 is equipped with two small-SCA cold-side ESPs operated in series. All ESP systems tested in this program had SCAs less than 250 ft2/1000 acfm. Short-term parametric tests were conducted on Yates

  20. Experimental evidence of nitrous acid formation in the electron beam treatment of flue gas

    International Nuclear Information System (INIS)

    Maetzing, H.; Namba, H.; Tokunaga, O.

    1994-01-01

    In the Electron Beam Dry Scrubbing (EBDS) process, flue gas from fossil fuel burning power plants is irradiated with accelerated (300-800 keV) electrons. Thereby, nitrogen oxide (NO x ) and sulfur dioxide (SO 2 ) traces are transformed into nitric and sulfuric acids, respectively, which are converted into particulate ammonium nitrate and sulfate upon the addition of ammonia. The powdery product can be filtered from the main gas stream and can be sold as agricultural fertilizer. A lot of experimental investigations have been performed on the EBDS process and computer models have been developed to interpret the experimental results and to predict economic improvements. According to the model calculations, substantial amounts of intermediate nitrous acid (HNO 2 ) are formed in the electron beam treatment of flue gas. The first experimental investigation about the formation of nitrous acid in an irradiated mixture of NO in synthetic air has been undertaken. Under these conditions, aerosol formation is avoided. UV spectra of the irradiated gas were recorded in the wavelength range λ = 345-375 nm. Both NO 2 and HNO 2 have characteristic absorption bands in this wavelength range. Calibration spectra of NO 2 were subtracted from the sample spectra. The remaining absorption bands can clearly be assigned to nitrous acid. The concentration of nitrous acid was determined by differential optical absorption. It was found lower than the model prediction. The importance of nitrous acid formation in the EBDS process needs to be clarified. (author)

  1. Possibilities of Mercury Removal in the Dry Flue Gas Cleaning Lines of Solid Waste Incineration Units

    Czech Academy of Sciences Publication Activity Database

    Svoboda, Karel; Hartman, Miloslav; Šyc, Michal; Pohořelý, Michael; Kameníková, Petra; Jeremiáš, Michal; Durda, Tomáš

    2016-01-01

    Roč. 166, JAN 15 (2016), s. 499-511 ISSN 0301-4797 R&D Projects: GA TA ČR TE02000236 Institutional support: RVO:67985858 Keywords : waste incineration * mercury removal * flue gas Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 4.010, year: 2016

  2. Organic Rankine cycle for power recovery of exhaust flue gas

    International Nuclear Information System (INIS)

    Guo, Cong; Du, Xiaoze; Yang, Lijun; Yang, Yongping

    2015-01-01

    To study the effects of different working fluids on the performance of organic Rankine cycle (ORC), three working fluids, a mixture that matches with heat source, a mixture that matches with heat sink and a pure working fluid, are selected in this paper. Thermodynamic models were built in Matlab together with REFPROP, with which, the physical properties of the selected working fluids can be acquired. Heat source of the ORC system is the exhaust flue gas of boiler in a 240 MW pulverized coal-fired power plant. Some indicators such as thermal efficiency, inlet temperature of expander, superheat degree, mass flow, volumetric flow, and exergy destruction distribution, as well as the influence of recuperator are studied. The analytical results show that the mixture that matches with heat sink has the greatest efficiency and the mixture that matches with heat source has the lowest superheat degree. The rate of heat exchanged in recuperator to that in evaporator has a maximum value with evaporating pressure. There exists no optimal working fluid for all indicators (thermal efficiency, heat exchanger area, mass flow and volumetric flow etc.). An appropriate working fluid should be chosen by taking both investment cost and power generating benefits into account. The cost-benefit ratio of the proposed ORC plant was evaluated either. - Highlights: • Three types of working fluids are selected for ORC using exhaust flue gas. • The mixture that matches with heat sink has the greatest efficiency. • The mixture that matches with heat source has the lowest superheat degree. • There does not exist a working fluid that satisfies all the indicators

  3. Land application uses for dry flue gas desulfurization by-products: Phase 3

    Energy Technology Data Exchange (ETDEWEB)

    Dick, W.; Bigham, J.; Forster, R.; Hitzhusen, F.; Lal, R.; Stehouwer, R.; Traina, S.; Wolfe, W.; Haefner, R.; Rowe, G.

    1999-01-31

    New flue gas desulfurization (FGD) scrubbing technologies create a dry, solid by-product material consisting of excess sorbent, reaction product that contains sulfate and sulfite, and coal fly ash. Generally, dry FGD by-products are treated as solid wastes and disposed in landfills. However, landfill sites are becoming scarce and tipping fees are constantly increasing. Provided the environmental impacts are socially and scientifically acceptable, beneficial uses via recycling can provide economic benefits to both the producer and the end user of the FGD. A study titled ''Land Application Uses for Dry Flue Gas Desulfurization By-Products'' was initiated in December, 1990 to develop and demonstrate large volume, beneficial uses of FGD by-products. Phase 1 and Phase 2 reports have been published by the Electric Power Research Institute (EPRI), Palo Alto, CA. Phase 3 objectives were to demonstrate, using field studies, the beneficial uses of FGD by-products (1) as an amendment material on agricultural lands and on abandoned surface coal mine land, (2) as an engineering material for soil stabilization and raid repair, and (3) to assess the environmental and economic impacts of such beneficial uses. Application of dry FGD by-product to three soils in place of agricultural limestone increased alfalfa (Medicago sativa L.) and corn (Zea may L.) yields. No detrimental effects on soil and plant quality were observed.

  4. Removal of Sulfur Dioxide from Flue Gas Using the Sludge Sodium Humate

    Directory of Open Access Journals (Sweden)

    Yu Zhao

    2013-01-01

    Full Text Available This study shows the ability of sodium humate from alkaline treatment sludge on removing sulfur dioxide (SO2 in the simulated flue gas. Experiments were conducted to examine the effect of various operating parameters, like the inlet SO2 concentration or temperature or O2, on the SO2 absorption efficiency and desulfurization time in a lab-scale bubbling reactor. The sludge sodium humate in the supernatant after alkaline sludge treatment shows great performance in SO2 absorption, and such efficiency can be maintained above 98% with 100 mL of this absorption solution at 298 K (flue gas rate of 0.12 m3/h. The highest SO2 absorption by 1.63 g SHA-Na is 0.946 mmol in the process, which is translated to 0.037 g SO2 g−1 SHA-Na. The experimental results indicate that the inlet SO2 concentration slightly influences the SO2 absorption efficiency and significantly influences the desulfurization time. The pH of the absorption solution should be above 3.5 in this process in order to make an effective desulfurization. The products of this process were characterized by Fourier transform infrared spectroscopy and X-ray diffraction. It can be seen that the desulfurization products mainly contain sludge humic acid sediment, which can be used as fertilizer components.

  5. Measurement of slurry droplets in coal-fired flue gas after WFGD.

    Science.gov (United States)

    Wu, Xue-Cheng; Zhao, Hua-Feng; Zhang, Yong-Xin; Zheng, Cheng-Hang; Gao, Xiang

    2015-10-01

    China owns the world's largest capacity of coal-fired power units. By the end of 2012, the capacity of installed national thermal power has been 819.68 million kilowatts. The latest standard requires that newly built power plants emit SO2 in no more than 100 mg/m(3) and the emission of old ones be lower than 200 mg/m(3) while in some key areas the emission should be controlled under 50 mg/m(3). So by the end of 2012, 90% of the active coal-fired units have been equipped with flue gas desulfurization devices. Among the desulfurization methods adopted, limestone-gypsum wet flue gas desulphurization accounts for 92%, causing the problem of fine droplets in the exhaust gas after defogger, which may even form "gypsum rain." At present, sampling methods are widely used at home and abroad, such as magnesium ion tracer method, modified magnesium ion tracer method and chemical analysis. In addition, some scholars use aerodynamic methods, such as ELPI, to measure the diameter distribution and concentration. The methods mentioned above all have their own demerits, such as the inability to on-line, continuous measurements and the need of prolonged measuring time. Thus, in this paper some potential optical on-line methods are presented, such as Fraunhofer diffraction pattern analysis and wavelength-multiplexed laser extinction. Also brought up are their measuring scope and merits. These methods have already been utilized to measure small liquid droplets and their demonstrations and evaluations are as well stated. Finally, a 3D imaging method based on digital holographic microscope is proposed for in-line measurement of size and concentration of slurry droplets. The feasibility of this method is demonstrated by preliminary experimental investigation.

  6. Removal of mercury from coal-combustion flue gas using regenerable sorbents

    Energy Technology Data Exchange (ETDEWEB)

    Turchi, C S; Albiston, J; Broderick, T E; Stewart, R M

    1999-07-01

    The US EPA estimates that coal-fired power plants constitute the largest anthropogenic source of mercury emissions in the US. The Agency has contemplated emission regulations for power plants, but the large gas-flow rates and low mercury concentrations involved have made current treatment options prohibitively expensive. ADA Technologies, Inc. (Englewood, Colorado), in conjunction with the US DOE, is developing regenerable sorbents for the removal and recovery of mercury from flue gas. These sorbents are based on the ability of noble metals to amalgamate mercury at typical flue-gas temperatures and release mercury at higher temperatures. The process allows for recovery of mercury with minimal volumes of secondary wastes and no impact on fly ash quality. In 1997 and 1998, ADA tested a 20-cfm sorbent unit at CONSOL Inc.'s coal-combustion test facility in Library, PA. Results from the 1997 tests indicated that the sorbent can remove elemental and oxidized mercury and can be regenerated without loss of capacity. Design changes were implemented in 1998 to enhance the thermal efficiency of the process and to recover the mercury in a stable form. Testing during autumn, 1998 demonstrated 60% to 90% removal efficiency of mercury from a variety of different coals. However, contradictory removal results were obtained at the end of the test period. Subsequent laboratory analyses indicated that the sorbent had lost over half its capacity for mercury due to a decrease in available sites for mercury sorption. The presence of sulfur compounds on the sorbent suggests that thermal cycling may have condensed acid gases on the sorbent leading to deterioration of the active sorption sites. The regeneration time/temperature profile has been altered to minimize this potential in the upcoming power plant tests.

  7. Industrial plant for electron beam flue gas treatment

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Iller, E.; Tyminnski, B.; Zimek, Z; Ostapczuk, A.; Licki, J.

    2001-01-01

    The electron beam flue gas treatment technology was invented many years ago. Research on the process has been carried out in Japan, USA, Germany and Poland. However, the recent fidings, based on the experiments performed at pilot plant at Electric Power Station Kaweczyn, led to developments which made process mature just at the dawn of the XXI century. The process is being implemented in the full industrial scale at Electric Power Station Pomorzany (Dolna Odra EPS Group). Other developments are reported in Japan and after Nagoya's pilot plant experiments, an industrial plant has been built in China and another one is constructed in Japan. There are remarkable differences in technological and design solutions applied in all these installations. Developments achieved at EPS Kaweczyn pilot plant and INCT laboratory unit were the basis for the project realized at EPS Pomorzan

  8. Hot gas path component having near wall cooling features

    Science.gov (United States)

    Miranda, Carlos Miguel; Kottilingam, Srikanth Chandrudu; Lacy, Benjamin Paul

    2017-11-28

    A method for providing micro-channels in a hot gas path component includes forming a first micro-channel in an exterior surface of a substrate of the hot gas path component. A second micro-channel is formed in the exterior surface of the hot gas path component such that it is separated from the first micro-channel by a surface gap having a first width. The method also includes disposing a braze sheet onto the exterior surface of the hot gas path component such that the braze sheet covers at least of portion of the first and second micro-channels, and heating the braze sheet to bond it to at least a portion of the exterior surface of the hot gas path component.

  9. CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS

    Energy Technology Data Exchange (ETDEWEB)

    David A. Green; Brian S. Turk; Raghubir Gupta; Alejandro Lopez-Ortiz

    2001-01-01

    Four grades of sodium bicarbonate and two grades of trona were characterized in terms of particle size distribution, surface area, pore size distribution, and attrition. Surface area and pore size distribution determinations were conducted after calcination of the materials. The sorbent materials were subjected to thermogravimetric testing to determine comparative rates and extent of calcination (in inert gas) and sorption (in a simulated coal combustion flue gas mixture). Selected materials were exposed to five calcination/sorption cycles and showed no decrease in either sorption capacity or sorption rate. Process simulations were conducted involving different heat recovery schemes. The process is thermodynamically feasible. The sodium-based materials appear to have suitable physical properties for use as regenerable sorbents and, based on thermogravimetric testing, are likely to have sorption and calcination rates that are rapid enough to be of interest in full-scale carbon sequestration processes.

  10. Two-Phase Phenomena In Wet Flue Gas Desulfurization Process

    International Nuclear Information System (INIS)

    Minzer, U.; Moses, E.J.; Toren, M.; Blumenfeld, Y.

    1998-01-01

    In order to reduce sulfur oxides discharge, Israel Electric Corporation (IEC) is building a wet Flue Gas Desulfurization (FGD) facility at Rutenberg B power station. The primary objective of IEC is to minimize the occurrence of stack liquid discharge and avoid the discharge of large droplets, in order to prevent acid rain around the stack. Liquid discharge from the stack is the integrated outcome of two-phase processes, which are discussed in this work. In order to estimate droplets discharge the present investigation employs analytical models, empirical tests, and numerical calculations of two-phase phenomena. The two-phase phenomena are coupled and therefore cannot be investigated separately. The present work concerns the application of Computational Fluid Dynamic (CFD) as an engineering complementary tool in the IEC investigation

  11. Torrefaction of cedarwood in a pilot scale rotary kiln and the influence of industrial flue gas.

    Science.gov (United States)

    Mei, Yanyang; Liu, Rujie; Yang, Qing; Yang, Haiping; Shao, Jingai; Draper, Christopher; Zhang, Shihong; Chen, Hanping

    2015-02-01

    Torrefaction of cedarwood was performed in a pilot-scale rotary kiln at various temperatures (200, 230, 260 and 290°C). The torrefaction properties, the influence on the grindability and hydroscopicity of the torrefied biomass were investigated in detail as well as the combustion performance. It turned out that, compared with raw biomass, the grindability and the hydrophobicity of the torrefied biomass were significantly improved, and the increasing torrefaction temperature resulted in a decrease in grinding energy consumption and an increase in the proportion of smaller-sized particles. The use of industrial flue gas had a significant influence on the behavior of cedarwood during torrefaction and the properties of the resultant solid products. To optimize the energy density and energy yield, the temperature of torrefaction using flue gas should be controlled within 260°C. Additionally, the combustion of torrefied samples was mainly the combustion of chars, with similar combustion characteristics to lignite. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Use of sulfide-containing liquors for removing mercury from flue gases

    Science.gov (United States)

    Nolan, Paul S.; Downs, William; Bailey, Ralph T.; Vecci, Stanley J.

    2006-05-02

    A method and apparatus for reducing and removing mercury in industrial gases, such as a flue gas, produced by the combustion of fossil fuels, such as coal, adds sulfide ions to the flue gas as it passes through a scrubber. Ideally, the source of these sulfide ions may include at least one of: sulfidic waste water, kraft caustic liquor, kraft carbonate liquor, potassium sulfide, sodium sulfide, and thioacetamide. The sulfide ion source is introduced into the scrubbing liquor as an aqueous sulfide species. The scrubber may be either a wet or dry scrubber for flue gas desulfurization systems.

  13. Impact of Leaching Conditions on Constituents Release from Flue Gas Desulfurization Gypsum (FGDG) and FGDG-Soil Mixture

    Science.gov (United States)

    The interest in using Flue Gas Desulfurization Gypsum(FGDG) has increased recently. This study evaluates the leaching characteristics of trace elements in "modern" FGDG (produced after fly ash removal) and FGDG-mixed soil (SF) under different environmental conditions using rece...

  14. Thermal preparation effects on the x-ray diffractograms of compounds produced during flue gas desulfurization

    International Nuclear Information System (INIS)

    Wertz, D.L.; Burns, K.H.; Keeton, R.W.

    1995-01-01

    The diffractograms of syn-gypsum and of flue gas desulfurization products indicate that CaSO 4 · 2H 2 O is converted to other phase(s) when heated to 100 degrees C. Syn-hannebachite CaSO 3 ·0.5H 2 O is unaffected by similar thermal treatment. 6 refs., 3 figs

  15. Mixotrophic cultivation of microalgae using industrial flue gases for biodiesel production.

    Science.gov (United States)

    Kandimalla, Pooja; Desi, Sreekanth; Vurimindi, Himabindu

    2016-05-01

    In the present study, an attempt has been made to grow microalgae Scenedesmus quadricauda, Chlorella vulgaris and Botryococcus braunii in mixotropic cultivation mode using two different substrates, i.e. sewage and glucose as organic carbon sources along with flue gas inputs as inorganic carbon source. The experiments were carried out in 500 ml flasks with sewage and glucose-enriched media along with flue gas inputs. The composition of the flue gas was 7 % CO2, 210 ppm of NO x and 120 ppm of SO x . The results showed that S. quadricauda grown in glucose-enriched medium yielded higher biomass, lipid and fatty acid methyl esters (FAME) (biodiesel) yields of 2.6, 0.63 and 0.3 g/L, respectively. Whereas with sewage, the biomass, lipid and FAME yields of S. quadricauda were 1.9, 0.46, and 0.21 g/L, respectively. The other two species showed closer results as well. The glucose utilization was measured in terms of Chemical Oxygen Demand (COD) reduction, which was up to 93.75 % by S. quadricauda in the glucose-flue gas medium. In the sewage-flue gas medium, the COD removal was achieved up to 92 % by S. quadricauda. The other nutrients and pollutants from the sewage were removed up to 75 % on an average by the same. Concerning the flue gas treatment studies, S. quadricauda could remove CO2 up to 85 % from the flue gas when grown in glucose medium and 81 % when grown in sewage. The SO x and NO x concentrations were reduced up to 50 and 62 %, respectively, by S. quadricauda in glucose-flue gas medium. Whereas, in the sewage-flue gas medium, the SO x and NO x concentrations were reduced up to 45 and 50 %, respectively, by the same. The other two species were equally efficient however with little less significant yields and removal percentages. This study laid emphasis on comparing the feasibility in utilization of readily available carbon sources like glucose and inexpensive leftover carbon sources like sewage by microalgae to generate energy coupled with economical

  16. Mercury Speciation in Coal-Fired Power Plant Flue Gas-Experimental Studies and Model Development

    Energy Technology Data Exchange (ETDEWEB)

    Radisav Vidic; Joseph Flora; Eric Borguet

    2008-12-31

    The overall goal of the project was to obtain a fundamental understanding of the catalytic reactions that are promoted by solid surfaces present in coal combustion systems and develop a mathematical model that described key phenomena responsible for the fate of mercury in coal-combustion systems. This objective was achieved by carefully combining laboratory studies under realistic process conditions using simulated flue gas with mathematical modeling efforts. Laboratory-scale studies were performed to understand the fundamental aspects of chemical reactions between flue gas constituents and solid surfaces present in the fly ash and their impact on mercury speciation. Process models were developed to account for heterogeneous reactions because of the presence of fly ash as well as the deliberate addition of particles to promote Hg oxidation and adsorption. Quantum modeling was used to obtain estimates of the kinetics of heterogeneous reactions. Based on the initial findings of this study, additional work was performed to ascertain the potential of using inexpensive inorganic sorbents to control mercury emissions from coal-fired power plants without adverse impact on the salability fly ash, which is one of the major drawbacks of current control technologies based on activated carbon.

  17. Application of radioisotope tracer techniques in evaluation of irradiation vessel of flue gas treatment system

    International Nuclear Information System (INIS)

    Joon-Ha Jin; Myun-Joo Lee; Sung-Hee Jung; Young-Chang Nho

    1998-01-01

    The proper design of the irradiation vessel of electron beam flue gases treatment plant and resultant optimum gas flow pattern is a very important factor to get a high removal efficiency of toxic materials from flue gases. Radioisotope tracer experiments were conducted to study the residence time distribution of gas flow in a cylindrical irradiation vessel. A few mCi of gaseous radioisotope tracer Ar-41 was injected to the upstream of the vessel and the input and output response were measured with two NaI scintillation detectors. The same experiment was conducted after the modification of the vessel by introducing 4 baffles. The experimental data were analyzed to calculate mean residence times and mixing characteristics of each system using the residence time distribution (RTD) analysis software. A method to estimate pollutant removal efficiencies of an irradiation vessel from the residence time distributions measured by radiotracer experiments was suggested. The analytical results were compared to evaluate the effect of the baffles on the removal efficiency of the plant

  18. Experimental optimization of temperature distribution in the hot-gas duct through the installation of internals in the hot-gas plenum of a high-temperature reactor

    International Nuclear Information System (INIS)

    Henssen, J.; Mauersberger, R.

    1990-01-01

    The flow conditions in the hot-gas plenum and in the adjacent hot-gas ducts and hot-gas pipes for the high-temperature reactor project PNP-1000 (nuclear process heat project for 1000 MW thermal output) have been examined experimentally. The experiments were performed in a closed loop in which the flow model to be analyzed, representing a 60deg sector of the core bottom of the PNP-1000 with connecting hot-gas piping and diverting arrangements, was installed. The model scale was approx. 1:5.6. The temperature and flow velocity distribution in the hot-gas duct was registered by means of 14 dual hot-wire flowmeters. Through structural changes and/or the installation of internals into the hot-gas plenum of the core bottom offering little flow resistance coolant gas temperature differentials produced in the core could be reduced to such an extent that a degree of mixture amounting to over 80% was achieved at the entrance of the connected heat exchanger systems. Thereby the desired goal of an adequate degree of mixture of the hot gas involving an acceptable pressure loss was reached. (orig.)

  19. Analysis of Halogen-Mercury Reactions in Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Paula Buitrago; Geoffrey Silcox; Constance Senior; Brydger Van Otten

    2010-01-01

    Oxidized mercury species may be formed in combustion systems through gas-phase reactions between elemental mercury and halogens, such as chorine or bromine. This study examines how bromine species affect mercury oxidation in the gas phase and examines the effects of mixtures of bromine and chlorine on extents of oxidation. Experiments were conducted in a bench-scale, laminar flow, methane-fired (300 W), quartz-lined reactor in which gas composition (HCl, HBr, NO{sub x}, SO{sub 2}) and temperature profile were varied. In the experiments, the post-combustion gases were quenched from flame temperatures to about 350 C, and then speciated mercury was measured using a wet conditioning system and continuous emissions monitor (CEM). Supporting kinetic calculations were performed and compared with measured levels of oxidation. A significant portion of this report is devoted to sample conditioning as part of the mercury analysis system. In combustion systems with significant amounts of Br{sub 2} in the flue gas, the impinger solutions used to speciate mercury may be biased and care must be taken in interpreting mercury oxidation results. The stannous chloride solution used in the CEM conditioning system to convert all mercury to total mercury did not provide complete conversion of oxidized mercury to elemental, when bromine was added to the combustion system, resulting in a low bias for the total mercury measurement. The use of a hydroxylamine hydrochloride and sodium hydroxide solution instead of stannous chloride showed a significant improvement in the measurement of total mercury. Bromine was shown to be much more effective in the post-flame, homogeneous oxidation of mercury than chlorine, on an equivalent molar basis. Addition of NO to the flame (up to 400 ppmv) had no impact on mercury oxidation by chlorine or bromine. Addition of SO{sub 2} had no effect on mercury oxidation by chlorine at SO{sub 2} concentrations below about 400 ppmv; some increase in mercury oxidation

  20. Screening of metal-organic frameworks for carbon dioxide capture from flue gas using a combined experimental and modeling approach.

    Science.gov (United States)

    Yazaydin, A Ozgür; Snurr, Randall Q; Park, Tae-Hong; Koh, Kyoungmoo; Liu, Jian; Levan, M Douglas; Benin, Annabelle I; Jakubczak, Paulina; Lanuza, Mary; Galloway, Douglas B; Low, John J; Willis, Richard R

    2009-12-30

    A diverse collection of 14 metal-organic frameworks (MOFs) was screened for CO(2) capture from flue gas using a combined experimental and modeling approach. Adsorption measurements are reported for the screened MOFs at room temperature up to 1 bar. These data are used to validate a generalized strategy for molecular modeling of CO(2) and other small molecules in MOFs. MOFs possessing a high density of open metal sites are found to adsorb significant amounts of CO(2) even at low pressure. An excellent correlation is found between the heat of adsorption and the amount of CO(2) adsorbed below 1 bar. Molecular modeling can aid in selection of adsorbents for CO(2) capture from flue gas by screening a large number of MOFs.

  1. Technical aspects of flue gas irradiation

    International Nuclear Information System (INIS)

    Cleland, M.R.; Galloway, R.A.; Stichelbaut, F.; Abs, M.

    2011-01-01

    Removal of SO 2 and NO x from flue gases in fossil-fueled power plants by irradiation with accelerated electrons was first investigated in Japan more than 30 years ago. This process has since been extensively evaluated in several pilot facilities in Japan, the USA, Germany, Poland, Bulgaria and China. Recently, it has advanced to the demonstration plant stage in Poland, Japan and China. Except for the initial research facility in Japan, which had a 5.5 MeV microwave linear accelerator, these facilities have used relatively low-energy dc accelerators rated from 0.3 MeV to 0.8 MeV. An attractive feature of such accelerators is their high electrical efficiency, which can exceed 90%. However, the electron beam power dissipated in the two titanium beam windows, the first on the accelerator and the second on the flue gas duct, and in the air space between the windows must also be taken into account. These beam power losses have been calculated as 54% at 0.50 MeV and 28% at 0.75 MeV, but they decrease further to 17% at 1.0 MeV, 9.3% at 1.5 MeV, 6.7% at 2.0 MeV, 5.2% at 2.5 MeV and 4.6% at 3.0 MeV. The use of accelerators providing electron energies higher than 0.75 MeV could facilitate the generation and delivery of the high beam current and beam power requirements for large electric power plants, which are about 1% to 2% of the electrical power output of the plant. Most of the pilot and demonstration facilities have used ammonia gas to neutralize the acid vapors produced during the irradiation process. The resulting by-products are ammonium sulfate and ammonium nitrate, which have value as agricultural fertilizers. On the other hand, two pilot facilities, one in the USA and the other in Japan, have shown that slaked lime (calcium hydroxide) is a possible alternative to ammonia. The resulting by-products in this case are calcium sulfate and calcium nitrate, which can be used as soil amendments or to make gypsum board (drywall) for interior construction in homes and

  2. Technical aspects of flue gas irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Cleland, M. R.; Galloway, R. A. [IBA Industrial, Inc., Edgewood, NY (United States); Stichelbaut, F.; Abs, M. [IBA Industrial, Inc., Louvain-la-Neuve (Belgium)

    2011-07-01

    Removal of SO{sub 2} and NO{sub x} from flue gases in fossil-fueled power plants by irradiation with accelerated electrons was first investigated in Japan more than 30 years ago. This process has since been extensively evaluated in several pilot facilities in Japan, the USA, Germany, Poland, Bulgaria and China. Recently, it has advanced to the demonstration plant stage in Poland, Japan and China. Except for the initial research facility in Japan, which had a 5.5 MeV microwave linear accelerator, these facilities have used relatively low-energy dc accelerators rated from 0.3 MeV to 0.8 MeV. An attractive feature of such accelerators is their high electrical efficiency, which can exceed 90%. However, the electron beam power dissipated in the two titanium beam windows, the first on the accelerator and the second on the flue gas duct, and in the air space between the windows must also be taken into account. These beam power losses have been calculated as 54% at 0.50 MeV and 28% at 0.75 MeV, but they decrease further to 17% at 1.0 MeV, 9.3% at 1.5 MeV, 6.7% at 2.0 MeV, 5.2% at 2.5 MeV and 4.6% at 3.0 MeV. The use of accelerators providing electron energies higher than 0.75 MeV could facilitate the generation and delivery of the high beam current and beam power requirements for large electric power plants, which are about 1% to 2% of the electrical power output of the plant. Most of the pilot and demonstration facilities have used ammonia gas to neutralize the acid vapors produced during the irradiation process. The resulting by-products are ammonium sulfate and ammonium nitrate, which have value as agricultural fertilizers. On the other hand, two pilot facilities, one in the USA and the other in Japan, have shown that slaked lime (calcium hydroxide) is a possible alternative to ammonia. The resulting by-products in this case are calcium sulfate and calcium nitrate, which can be used as soil amendments or to make gypsum board (drywall) for interior construction in homes

  3. Recent status of purging SO2 and NOx in flue gas by EB and R and D of electron accelerator in China

    International Nuclear Information System (INIS)

    Liu Zhenhao

    2005-01-01

    The main energy resource is coal in China. Flue gas from burning coal is the most fearful pollution. Chinese Government pays more attention to reduction of SO 2 in flue gas from 1990's. Various technical facilities of reducing SO 2 have been imported from developed countries especially from Japanese companies. For example, A largest project is that Chongqing-luohuang electric power station imported limestone-gypsum process FGD technology and facility from Mitsubishi of Japan in 1980s for 300 MW generator spending 36.4 million US$ and 27.3 million RMB. Recently an example is EBA technology in Chengdu thermal plant. Some of Chinese institute is going to improve the technology to treat larger amount of flue gas from one generator such as 200 - 300 MW generator. And an R and D program of manufacturing higher voltage accelerator is being implemented. Otherwise, electron accelerator of industry application has been successfully made from 20 kW - 100 kW with 2.5 MeV energy in China. (author)

  4. Biological carbon fixation: A study of Isochrysis sp. growth under actual coal-fired power plant's flue gas

    International Nuclear Information System (INIS)

    Yahya, Liyana; Chik, Muhammad Nazry; Pang, Mohd Asyraf Mohd Azmir

    2013-01-01

    Preliminary study on the growth of marine microalgae Isochrysis sp. was carried out using actual flue gas from a coal-fired power station. The species was cultured using a 2×10-L customized bubble column photobioreactor skid under specified culture conditions. With an initial culture density of 0.459 Abs (optical density at 560 nm wavelength), the species was found able to survive – observed by increases in optical densities, number of cells and weights – in the presence of actual coal-fired flue gas containing on average 4.08 % O 2 , 200.21 mg/m 3 SO 2 , 212.29 mg/m 3 NO x , 4.73 % CO 2 and 50.72 mg/m 3 CO. Results thus add value to the potential and capability of microalgae, especially for Isochrysis sp., to be the biological carbon fixer in neutralizing carbon emissions from power plants.

  5. The Clean Coal Technology Program 100 MWe demonstration of gas suspension absorption for flue gas desulfurization

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, F.E.; Hedenhag, J.G. [AirPol Inc., Teterboro, NJ (United States); Marchant, S.K.; Pukanic, G.W. [Dept. of Energy, Pittsburgh, PA (United States). Pittsburgh Energy Technology Center; Norwood, V.M.; Burnett, T.A. [Tennessee Valley Authority, Chattanooga, TN (United States)

    1997-12-31

    AirPol Inc., with the cooperation of the Tennessee Valley Authority (TVA) under a Cooperative Agreement with the United States Department of Energy, installed and tested a 10 MWe Gas Suspension Absorption (GSA) Demonstration system at TVA`s Shawnee Fossil Plant near Paducah, Kentucky. This low-cost retrofit project demonstrated that the GSA system can remove more than 90% of the sulfur dioxide from high-sulfur coal-fired flue gas, while achieving a relatively high utilization of reagent lime. This paper presents a detailed technical description of the Clean Coal Technology demonstration project. Test results and data analysis from the preliminary testing, factorial tests, air toxics texts, 28-day continuous demonstration run of GSA/electrostatic precipitator (ESP), and 14-day continuous demonstration run of GSA/pulse jet baghouse (PJBH) are also discussed within this paper.

  6. Microbial reduction of SO[sub 2] and NO[sub x] as a means of by- product recovery/disposal from regenerable processes for the desulfurization of flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Sublette, K.L.

    1992-01-01

    Based on the work described simultaneous SO[sub 2]/No[sub x] removal from flue gas based on direct contact of the gas with SRB and T. denitrificans co-cultures or cultures-in-series has been eliminated as a viable process concept at this time. The technical reasons are as follows: (1) NO inhibition of SO[sub 2] reduction by D. desulfuricans - Although the NO concentrations used in the experiments described above are somewhat higher than that found in a typical flue gas, it is quite possible that at lower NO concentrations (or partial pressures) the inhibiting effects will simply take longer to become apparent. (2) Nitrate suppression of NO removal - As noted previously, the cultivation of T. denitrificans in a microbial flue gas treatment system (either one or two stages) would require sulfide-limiting conditions. Therefore, the electron acceptor must be in excess, requiring nitrate in the T. denitrificans process culture. As shown in experiments described above, nitrate significantly suppresses the removal of NO from a feed gas making simultaneous SO[sub 2]/NO[sub x] removal impractical by microbial means. (3) O[sub 2] inhibition of SO[sub 2] and NO reduction - It has been demonstrated that D. desulfuricans working cultures are tolerant of up to 1.7% O[sub 2] in the feed gas. However, further increases in the O[sub 2] partial pressure in the feed gas resulted in O[sub 2] inhibition of SO[sub 2] reduction. These inhibiting levels of O[sub 2] are comparable to those concentrations found in flue gases (3). Therefore, in any process in which raw flue gas contacts a D. desulfuricans culture marginal stability at best can be expected.

  7. Ion swarm data for electrical discharge modeling in air and flue gas mixtures

    International Nuclear Information System (INIS)

    Nelson, D.; Benhenni, M.; Eichwald, O.; Yousfi, M.

    2003-01-01

    The first step of this work is the determination of the elastic and inelastic ion-molecule collision cross sections for the main ions (N 2 + , O 2 + , CO 2 + , H 2 O + and O - ) usually present either in the air or flue gas discharges. The obtained cross section sets, given for ion kinetic energies not exceeding 100 eV, correspond to the interactions of each ion with its parent molecule (symmetric case) or nonparent molecule (asymmetric case). Then by using these different cross section sets, it is possible to obtain the ion swarm data for the different gas mixtures involving N 2 , CO 2 , H 2 O and O 2 molecules whatever their relative proportions. These ion swarm data are obtained from an optimized Monte Carlo method well adapted for the ion transport in gas mixtures. This also allows us to clearly show that the classical linear approximations usually applied for the ion swarm data in mixtures such as Blanc's law are far to be valid. Then, the ion swarm data are given in three cases of gas mixtures: a dry air (80% N 2 , 20% O 2 ), a ternary gas mixture (82% N 2 , 12% CO 2 , 6% O 2 ) and a typical flue gas (76% N 2 , 12% CO 2 , 6% O 2 , 6% H 2 O). From these reliable ion swarm data, electrical discharge modeling for a wire to plane electrode configuration has been carried out in these three mixtures at the atmospheric pressure for different applied voltages. Under the same discharge conditions, large discrepancies in the streamer formation and propagation have been observed in these three mixture cases. They are due to the deviations existing not only between the different effective electron-molecule ionization rates but also between the ion transport properties mainly because of the presence of a highly polar molecule such as H 2 O. This emphasizes the necessity to properly consider the ion transport in the discharge modeling

  8. Wet flue gas desulphurization and new fuels

    Energy Technology Data Exchange (ETDEWEB)

    Kiil, S.; Dam-Johansen, K.; Michelsen, M.L.

    1998-04-01

    This thesis describes experimental and theoretical investigations of wet flue gas desulphurization (FGD). A review of the current knowledge of the various rate determining steps in wet FDG plants is presented. The mechanism underlying the rate of dissolution of finely grained limestone particles was examined in a laboratory batch apparatus using acid titration. Three Danish limestones of different origin were tested. A transient, mass transport controlled, mathematical model was developed to describe the dissolution process. Model predictions were found to be qualitatively in good agreement with experimental data. Empirical correlations for the dimensionless mass transfer coefficients in a pilot plant (falling-film column) were determined. The presence of inert particles in the liquid phase was found to decrease the rate of gas phase mass transport with up to 15%, though the effect could not be correlated. A detailed model for a wet FGD pilot plant, based on the falling film principle, was developed. All important rate determining steps, absorption of SO{sub 2}, oxidation of HSO{sub 3}{sup -}, dissolution of limestone, and crystallisation of gypsum were included. Model predictions were compared to experimental data such as gas phase concentration profiles of SO{sub 2}, slurry pH-profiles, solids contents of slurry, liquid phase concentrations, and residual limestone in the gypsum. The possibility of co-firing straw and coal was investigated in a full-scale power plant. No effects on the overall performance of the wet FGD plant were observed, though laboratory experiments with fine dust and fly ash from the full-scale experiments showed a decrease in limestone reactivity. (EG) EFP-95. 45 refs.; Also ph.d. thesis of Soeren Kiil

  9. Effects of foaming and antifoaming agents on the performance of a wet flue gas desulfurization pilot plant

    DEFF Research Database (Denmark)

    Qin, Siqiang; Hansen, Brian Brun; Kiil, Søren

    2014-01-01

    Foaming is a common phenomenon in industrial processes, including wet flue gas desulfurization (FGD) plants. A systemic investigation of the influence of two foaming agents, sodium dodecyl sulphate (SDS) and egg white albumin (protein), and two commercial antifoams on a wet FGD pilot plant...

  10. Computer simulation f the genetic controller for the EB flue gas treatment process

    International Nuclear Information System (INIS)

    Moroz, Z.; Bouzyk, J.; Sowinski, M.; Chmielewski, A.G.

    2001-01-01

    The use of computer genetic algorithm (GA) for driving a controller device for the industrial flue gas purification systems employing the electron beam irradiation, has been studied. As the mathematical model of the installation the properly trained artificial neural net (ANN) was used. Various cost functions and optimising strategies of the genetic code were tested. These computer simulations proved, that ANN + GA controller can be sufficiently precise and fast to be applied in real installations. (author)

  11. Determination of the main parameters of the cyclone separator of the flue gas produced during the smelting of secondary aluminum

    Science.gov (United States)

    Matusov, Jozef; Gavlas, Stanislav

    2016-06-01

    One way how is possible to separate the solid particulate pollutants from the flue gas is use the cyclone separators. The cyclone separators are very frequently used separators due to the simplicity of their design and their low operating costs. Separation of pollutants in the form of solids is carried out using three types of forces: inertia force, centrifugal force, gravity force. The main advantage is that cyclone consist of the parts which are resistant to wear and have long life time, e.g. various rotating and sliding parts. Mostly are used as pre-separators, because they have low efficiency in the separation of small particles. Their function is to separate larger particles from the flue gases which are subsequently cleaned in the other device which is capable of removing particles smaller than 1 µm, which is limiting size of particle separation. The article will deal with the issue of calculating the basic dimensions and main parameters of the cyclone separator from flue gas produced during the smelting of secondary aluminum.

  12. A study on removal of elemental mercury in flue gas using fenton solution

    International Nuclear Information System (INIS)

    Liu, Yangxian; Wang, Yan; Wang, Qian; Pan, Jianfeng; Zhang, Yongchun; Zhou, Jianfei; Zhang, Jun

    2015-01-01

    Highlights: • A novel technique on oxidation of Hg 0 using Fenton was proposed. • The effects of several process parameters on Hg 0 removal were studied. • Products and ·OH in solution were detected. • Reaction mechanism of Hg 0 removal was studied. • Simultaneous removal of Hg 0 , NO and SO 2 was also studied. - Abstract: A novel technique on oxidation-separation of elemental mercury (Hg 0 ) in flue gas using Fenton solution in a bubbling reactor was proposed. The effects of several process parameters (H 2 O 2 concentration, Hg 0 inlet concentration, Fe 2+ concentration, solution temperature, solution pH, gas flow) and several flue gas components (NO, SO 2 , O 2 , CO 2 , inorganic ions and particulate matters on Hg 0 removal were studied. The results indicate that H 2 O 2 concentration, Fe 2+ concentration, solution pH and gas flow have great effects on Hg 0 removal. Solution temperature, Hg 0 , NO, SO 2 , CO 3 2− and HCO 3 − concentrations also have significant effects on Hg 0 removal. However, Cl − , SO 4 2− , NO 3 − , O 2 and CO 2 concentrations only have slight effects on Hg 0 removal. Furthermore, reaction mechanism of Hg 0 removal and simultaneous removal process of Hg 0 , NO and SO 2 were also studied. Hg 0 is removed by oxidation of ·OH and oxidation of H 2 O 2 . The simultaneous removal efficiencies of 100% for SO 2 , 100% for Hg 0 and 88.3% for NO were obtained under optimal test conditions. The results demonstrated the feasibility of Hg 0 removal and simultaneous removal of Hg 0 , SO 2 and NO using Fenton solution in a bubbling reactor

  13. Status and perspectives for the electron beam technology for flue gases treatment

    International Nuclear Information System (INIS)

    Frank, N.W.

    1992-01-01

    The electron-beam process is one of the most effective methods of removing SO 2 and NO x from industrial flue gases. This flue gas treatment consists of adding a small amount of ammonia to the flue gas and irradiating the gas by means of an electron beam, thereby causing reactions which convert the SO 2 and NO x to ammonium sulfate and ammonium sulfate-nitrate. These salts may then be collected from the flue gas by means of such conventional collectors as an electrostatic precipitator or baghouse. This process has numerous advantages over currently-used conventional processes as follows: (1) the process simultaneously removes SO 2 and NO x from flue gas at high efficiency levels; (2) it is a dry process which is easily controlled and has excellent load-following capability; (3) stack-gas reheat is not required; (4) the pollutants are converted into a saleable agricultural fertilizer; (5) the process has low capital and operating cost requirements. The history of the process is shown with a summary of the work that is presently underway. All of the current work is for the purpose of fine tuning the process for commercial usage. It is believed that with current testing and improvements, the process will be very competitive with existing processes and it will find its place in an environmentally conscious world. (Author)

  14. Thermo Dynamics and Economics Evaluations: Substitution of the Extraction Steam with the Wasted Heat of Flue Gas

    Science.gov (United States)

    Hao, Lifen; Qiu, Lixia; Li, Jinping; Li, Dongxiong

    2018-01-01

    A new heat supplying system is proposed that utilizes the exhausted gas of the boiler to substitute the extraction steam from the turbine as the driving force for the adsorption heat pump regarding the recovery of the condensation heat of power plant. However, our system is not subject to the low efficiency of wasted heat utilization due to the low temperature of flue gas, which hence possesses higher performance in COP factors in the utilization of heat than that of the conventional techniques of using flues gas, so the amount of extracted gas from turbine can be reduced and the power generate rate be enhanced. Subsequently, detailed evaluation of the performance of this system in the point of views of thermodynamics and economics are presented in this work. For the instance of a 330 MW heat supply unit, 5 sample cities are chosen to demonstrate and confirm our economic analysis. It is revealed that when the heating coefficient of the heat pump is 1.8, the investment payback periods for these 5 cities are within the range of 2.4 to 4.8 years, which are far below the service year of the heat pump, demonstrating remarkable economic benefits for our system.

  15. Evolution and perspectives in waste incineration emissions and flue gas cleaning systems in the last 20 years

    International Nuclear Information System (INIS)

    Giugliano, M.; Cernuschi, S.; Grosso, M.

    2006-01-01

    The evolution of the technology of waste combustion, energy recovery and flue gas treatment allows to redefine the role of the incineration plant as a basic component of integrated waste management systems. Starting with an overview of the evaluation of emission limits and of the new Best Available Techniques (BAT) approach, strongly recommended by the European Union, the paper reports an overview of the stack emission concentrations measured in recent plants in Italy compared to older ones, with special attention to the dioxin issue. Concerning this topic, it is demonstrated that BAT-equipped plants can act as actual dioxin destroyer rather than producers, even when all the fluxes released in the environment (gaseous, solid and liquid residues) are taken into account. The second part of the paper deals with the evolution of the flue gas control technologies of the last 20 years, pointing out the major trends and the future perspectives for further increases of the removal monitoring of conventional and trace pollutants are briefly described [it

  16. Simulation of the influence of flue gas cleaning system on the energetic efficiency of a waste-to-energy plant

    Energy Technology Data Exchange (ETDEWEB)

    Grieco, E.; Poggio, A. [Politecnico di Torino, Corso Duca degli Abruzzi 24, Torino 10121 (Italy)

    2009-09-15

    Municipal solid waste incinerators are designed to enhance the electrical efficiency obtained by the plant as much as possible. For this reason strong integration between the flue gas cleaning system and the heat recovery system is required. To provide higher electrical efficiencies acid gas neutralization process has the major importance in flue gas cleaning system. At least four technologies are usually applied for acid gas removal: dry neutralization with Ca(OH){sub 2} or with NaHCO{sub 3}, semi-dry neutralization with milk of lime and wet scrubbing. Nowadays, wet scrubbers are rarely used as a result of the large amount of liquid effluents produced; wet scrubbing technology is often applied as a final treatment after a dry neutralization. Operating conditions of the plant were simulated by using Aspen Plus in order to investigate the influences of four different technologies on the electrical efficiency of the plant. The results of the simulations did not show a great influence of the gas cleaning system on the net electrical efficiency, as the difference between the most advantageous technology (neutralization with NaHCO{sub 3}) and the worst one, is about 1%. (author)

  17. SOx-NOx-Rox Box{trademark} flue gas clean-up demonstration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    Babcock and Wilcox`s (B and W) SOx-NOx-Rox Box{trademark} process effectively removes SOx, NOx and particulate (Rox) from flue gas generated from coal-fired boilers in a single unit operation, a high temperature baghouse. The SNRB technology utilizes dry sorbent injection upstream of the baghouse for removal of SOx and ammonia injection upstream of a zeolitic selective catalytic reduction (SCR) catalyst incorporated in the baghouse to reduce NOx emissions. Because the SOx and NOx removal processes require operation at elevated gas temperatures (800--900 F) for high removal efficiency, high-temperature fabric filter bags are used in the baghouse. The SNRB technology evolved from the bench and laboratory pilot scale to be successfully demonstrated at the 5-MWe field scale. This report represents the completion of Milestone M14 as specified in the Work Plan. B and W tested the SNRB pollution control system at a 5-MWe demonstration facility at Ohio Edison`s R.E. Burger Plant located near Shadyside, Ohio. The design and operation were influenced by the results from laboratory pilot testing at B and W`s Alliance Research Center. The intent was to demonstrate the commercial feasibility of the SNRB process. The SNRB facility treated a 30,000 ACFM flue gas slipstream from Boiler No. 8. Operation of the facility began in May 1992 and was completed in May 1993. About 2,300 hours of high-temperature operation were achieved. The main emissions control performance goals of: greater than 70% SO{sub 2} removal using a calcium-based sorbent; greater than 90% NOx removal with minimal ammonia slip; and particulate emissions in compliance with the New Source Performance Standards (NSPS) of 0.03 lb/million Btu were exceeded simultaneously in the demonstration program when the facility was operated at optimal conditions. Testing also showed significant reductions in emissions of some hazardous air pollutants.

  18. The impact of wet flue gas desulfurization scrubbing on mercury emissions from coal-fired power stations.

    Science.gov (United States)

    Niksa, Stephen; Fujiwara, Naoki

    2005-07-01

    This article introduces a predictive capability for Hg retention in any Ca-based wet flue gas desulfurization (FGD) scrubber, given mercury (Hg) speciation at the FGD inlet, the flue gas composition, and the sulphur dioxide (SO2) capture efficiency. A preliminary statistical analysis of data from 17 full-scale wet FGDs connects flue gas compositions, the extents of Hg oxidation at FGD inlets, and Hg retention efficiencies. These connections clearly signal that solution chemistry within the FGD determines Hg retention. A more thorough analysis based on thermochemical equilibrium yields highly accurate predictions for total Hg retention with no parameter adjustments. For the most reliable data, the predictions were within measurement uncertainties for both limestone and Mg/lime systems operating in both forced and natural oxidation mode. With the U.S. Environmental Protection Agency's (EPA) Information Collection Request (ICR) database, the quantitative performance was almost as good for the most modern FGDs, which probably conform to the very high SO2 absorption efficiencies assumed in the calculations. The large discrepancies for older FGDs are tentatively attributed to the unspecified SO2 capture efficiencies and operating temperatures and to the possible elimination of HCl in prescrubbers. The equilibrium calculations suggest that Hg retention is most sensitive to inlet HCl and O2 levels and the FGD temperature; weakly dependent on SO2 capture efficiency; and insensitive to HgCl2, NO, CA:S ratio, slurry dilution level in limestone FGDs, and MgSO3 levels in Mg/lime systems. Consequently, systems with prescrubbers to eliminate HCl probably retain less Hg than fully integrated FGDs. The analysis also predicts re-emission of Hg(O) but only for inlet O2 levels that are much lower than those in full-scale FGDs.

  19. MSW oxy-enriched incineration technology applied in China: combustion temperature, flue gas loss and economic considerations.

    Science.gov (United States)

    Fu, Zhe; Zhang, Shihong; Li, Xiangpeng; Shao, Jingai; Wang, Ke; Chen, Hanping

    2015-04-01

    To investigate the application prospect of MSW oxy-enriched incineration technology in China, the technical and economical analyses of a municipal solid waste (MSW) grate furnace with oxy-fuel incineration technology in comparison to co-incineration with coal are performed. The rated capacity of the grate furnace is 350 tonnes MSW per day. When raw MSW is burned, the amount of pure oxygen injected should be about 14.5 wt.% under 25% O2 oxy-fuel combustion conditions with the mode of oxygen supply determined by the actual situation. According to the isothermal combustion temperature (Ta), the combustion effect of 25% O2 oxy-enriched incineration (α = 1.43) is identical with that of MSW co-incineration with 20% mass ratio of coal (α = 1.91). However, the former is better than the latter in terms of plant cost, flue gas loss, and environmental impact. Despite the lower costs of MSW co-incineration with mass ratio of 5% and 10% coal (α = 1.91), 25% O2 oxy-enriched incineration (α = 1.43) is far more advantageous in combustion and pollutant control. Conventional combustion flue gas loss (q2) for co-incineration with 0% coal, 20% coal, 10% coal, 5% coal are around 17%, 13%, 14% and 15%, respectively, while that under the condition of 25% O2 oxy-enriched combustion is approximately 12% (α = 1.43). Clearly, q2 of oxy-enriched incineration is less than other methods under the same combustion conditions. High moisture content presents challenges for MSW incineration, therefore it is necessary to dry MSW prior to incineration, and making oxy-enriched incineration technology achieves higher combustion temperature and lower flue gas loss. In conclusion, based on technical and economical analysis, MSW oxy-enriched incineration retains obvious advantages and demonstrates great future prospects for MSW incineration in China. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Carbon Mineralization by Aqueous Precipitation for Beneficial Use of CO2 from Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Devenney, Martin; Gilliam, Ryan; Seeker, Randy

    2013-08-01

    The objective of this project is to demonstrate an innovative process to mineralize CO2 from flue gas directly to reactive carbonates and maximize the value and versatility of its beneficial use products. The program scope includes the design, construction, and testing of a CO2 Conversion to Material Products (CCMP) Pilot Demonstration Plant utilizing CO2 from the flue gas of a power production facility in Moss Landing, CA. This topical report covers Subphase 2a which is the design phase of pilot demonstration subsystems. Materials of construction have been selected and proven in both lab scale and prototype testing to be acceptable for the reagent conditions of interest. The target application for the reactive carbonate material has been selected based upon small-scale feasibility studies and the design of a continuous fiber board production line has been completed. The electrochemical cell architecture and components have been selected based upon both lab scale and prototype testing. The appropriate quality control and diagnostic techniques have been developed and tested along with the required instrumentation and controls. Finally the demonstrate site infrastructure, NEPA categorical exclusion, and permitting is all ready for the construction and installation of the new units and upgrades.

  1. Performance prediction of heat exchanger for waste heat recovery from humid flue gases

    International Nuclear Information System (INIS)

    Jeong, Dong Woon; Lee, Sang Yong; Lee, Han Ju

    2000-01-01

    A simulation program using the mass transfer correlation was constructed to analyze 1-D simplified condensing flow across the tube bank. Higher efficiency was anticipated by reducing the flue gas temperature down below the dew point where the water vapor in the flue gas is condensed at the surface of the heat exchanger; that is, the heat transfer by the latent heat is added to that by the sensible heat. Thus, there can be an optimum operating condition to maximize the heat recovery from the flue gas. The temperature rises of the flue gas and the cooling water between the inlet and the outlet of the tube bank were compared with the experimental data reported previously. The predicted results agree well with the experimental data. Using this simulation program, the parametric studies have been conducted for various operating conditions, such as the velocities and temperatures of the vapor/gas mixture and the cooling water, the number of the rows, and the conductivity of the wall material

  2. Dynamic modeling of fixed-bed adsorption of flue gas using a variable mass transfer model

    International Nuclear Information System (INIS)

    Park, Jehun; Lee, Jae W.

    2016-01-01

    This study introduces a dynamic mass transfer model for the fixed-bed adsorption of a flue gas. The derivation of the variable mass transfer coefficient is based on pore diffusion theory and it is a function of effective porosity, temperature, and pressure as well as the adsorbate composition. Adsorption experiments were done at four different pressures (1.8, 5, 10 and 20 bars) and three different temperatures (30, 50 and 70 .deg. C) with zeolite 13X as the adsorbent. To explain the equilibrium adsorption capacity, the Langmuir-Freundlich isotherm model was adopted, and the parameters of the isotherm equation were fitted to the experimental data for a wide range of pressures and temperatures. Then, dynamic simulations were performed using the system equations for material and energy balance with the equilibrium adsorption isotherm data. The optimal mass transfer and heat transfer coefficients were determined after iterative calculations. As a result, the dynamic variable mass transfer model can estimate the adsorption rate for a wide range of concentrations and precisely simulate the fixed-bed adsorption process of a flue gas mixture of carbon dioxide and nitrogen.

  3. Study of flue-gas temperature difference in supercritical once-through boiler

    Science.gov (United States)

    Kang, Yanchang; Li, Bing; Song, Ang

    2018-02-01

    The 600 MW coal-fired once-through Boilers with opposed firing at a power plant are found to experience marked temperature variation and even overtemperature on the wall of the heating surface as a result of flue-gas temperature (FGT) variation in the boiler. In this study, operational adjustments were made to the pulverizing, combustion, and secondary air box systems in these boilers, in order to solve problems in internal combustion. The adjustments were found to reduce FGT difference and optimize the boiler’ combustion conditions. The results of this study can provide a reference for optimization of coal-fired boiler of the same type in similar conditions.

  4. PH adjustment of power plant cooling water with flue gas/fly ash

    Science.gov (United States)

    Brady, Patrick V.; Krumhansl, James L.

    2015-09-22

    A system including a vessel including a heat source and a flue; a turbine; a condenser; a fluid conduit circuit disposed between the vessel, the turbine and the condenser; and a diverter coupled to the flue to direct a portion of an exhaust from the flue to contact with a cooling medium for the condenser water. A method including diverting a portion of exhaust from a flue of a vessel; modifying the pH of a cooling medium for a condenser with the portion of exhaust; and condensing heated fluid from the vessel with the pH modified cooling medium.

  5. Pilot-scale test on electron beam treatment of municipal solid waste flue gas with spraying slaked-lime slurry

    International Nuclear Information System (INIS)

    You Osada; Masahiro Sudo; Koichi Hirota

    1995-01-01

    Simultaneous removal of NO x , SO 2 and HCl in flue gas of a municipal solid waste incinerator was studied by using electron beam irradiation technology. The flue gas of around 1000 Nm 3 /h was led to a spray-dryer-type reactor from an inlet of ESP of the municipal waste incinerator by spraying slaked-lime slurry with one or more stoichiometric amount of the pollutants, concentrations of HCl (400 ppm) and SO 2 (50 ppm) decreased almost completely, while concentrations of NO x (100 ppm) were markedly decreased to about 20 ppm by electron beam irradiation with a dose of 10 kGy at 150 o C under spraying slaked-lime slurry of two stoichiometric amounts. The removal of NO x was improved by increasing the dose and the amount of spraying slaked-lime slurry, and by lowering of the irradiation temperature. (Author)

  6. Hot-Gas Filter Ash Characterization Project

    Energy Technology Data Exchange (ETDEWEB)

    Swanson, M.L.; Hurley, J.P.; Dockter, B.A.; O`Keefe, C.A.

    1997-07-01

    Large-scale hot-gas filter testing over the past 10 years has revealed numerous cases of cake buildup on filter elements that has been difficult, if not impossible, to remove. At times, the cake can blind or bridge between candle filters, leading to filter failure. Physical factors, including particle-size distribution, particle shape, the aerodynamics of deposition, and system temperature, contribute to the difficulty in removing the cake, but chemical factors such as surface composition and gas-solid reactions also play roles in helping to bond the ash to the filters or to itself. This project is designed to perform the research necessary to determine the fuel-, sorbent-, and operations-related conditions that lead to blinding or bridging of hot-gas particle filters. The objectives of the project are threefold: (1) Determine the mechanisms by which a difficult-to-clean ash is formed and how it bridges hot-gas filters (2) Develop a method to determine the rate of bridging based on analyses of the feed coal and sorbent, filter properties, and system operating conditions and (3) Suggest and test ways to prevent filter bridging.

  7. CO_2 capture from flue gas using clathrate formation in the presence of thermodynamic promoters

    International Nuclear Information System (INIS)

    Kim, Soyoung; Choi, Sung-Deuk; Seo, Yongwon

    2017-01-01

    Tetrahydrofuran (THF) as a water-soluble sII clathrate former, cyclopentane (CP) as a water-insoluble sII clathrate former, and tetra n-butyl ammonium chloride (TBAC) as a water-soluble semiclathrate former were used to investigate their thermodynamic promotion effects on clathrate-based CO_2 capture from simulated flue gas. The phase equilibria of CO_2 (20%) + N_2 (80%) + promoter clathrates at different promoter concentrations revealed that the presence of THF, CP, and TBAC could significantly reduce the clathrate formation pressure. THF solutions provided the highest gas uptake and steepest CO_2 concentration changes in the vapor phase, whereas TBAC solutions showed the highest CO_2 selectivity (∼61%) in the clathrate phase. CP solutions exhibited a slower formation rate, but their final gas uptake and CO_2 selectivity in the clathrate phase were comparable to the THF solutions. Raman spectroscopy confirmed the enclathration of both CO_2 and N_2 in the clathrate cages and a structural transition due to the inclusion of promoters in the clathrate phase. The overall experimental results indicate that TBAC is a viable thermodynamic promoter for clathrate-based CO_2 capture from simulated flue gas, considering the lower pressure requirement for clathrate formation, higher CO_2 enrichment in the clathrate phase, non-toxicity, and non-volatility. - Highlights: • Clathrate-based CO_2 capture was investigated in the presence of thermodynamic promoters. • THF, CP, and TBAC demonstrated a significant thermodynamic promotion for CO_2 (20%) + N_2 (80%) clathrates. • The highest gas uptake was observed for the THF (5.6 mol%) solution. • TBAC solutions showed the highest CO_2 selectivity in the clathrate phase (∼61%). • Raman spectroscopy confirmed the guest gas enclathration and clathrate structure.

  8. Thermal performance test of the hot gas ducts of HENDEL

    International Nuclear Information System (INIS)

    Hishida, M.; Kunitomi, K.; Ioka, I.; Umenishi, K.; Tanaka, T.; Shimomura, H.; Sanokawa, K.

    1984-01-01

    A hot gas duct provided with internal thermal insulation is to be used for high-temperature gas-cooled reactors (HTGR). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of a hot gas duct have been conducted. The present report deals with the results of the thermal performance of the single tube type hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL). Uniform temperature and heat flux distribution at the surface of the duct were observed, the experimental correlations being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of the co-axial hot gas duct was evaluated and no hot spot was detected. These results would be very valuable for the design and development of HTGR. (orig.)

  9. Permitting and solid waste management issues for the Bailly Station wet limestone Advanced Flue Gas Desulfurization (AFGD) system

    International Nuclear Information System (INIS)

    Bolinsky, F.T.; Ross, J.; Dennis, D.S.

    1991-01-01

    Pure Air (a general partnership between Air Products and Chemicals, Inc., and Mitsubishi Heavy Industries America, Inc.). is constructing a wet limestone co-current advanced flue gas desulfurization (AFGD) system that has technological and commercial advantages over conventional FGD systems in the United States. The AFGD system is being installed at the Northern Indiana Public Service Company's Bailly Generating Station near Gary, Indiana. The AFGD system is scheduled to be operational by the Summer, 1992. The AFGD system will remove at least 90 percent of the sulfur dioxide (SO 2 ) in the flue gas from Boilers 7 and 8 at the Station while burning 3.2 percent sulfur coal. Also as part of testing the AFGD system, 95 percent removal of SO 2 will be demonstrated on coals containing up to 4.5 percent sulfur. At the same time that SO 2 is removed from the flue gas, a gypsum by-product will be produced which will be used for wallboard manufacturing. Since the AFGD system is a pollution control device, one would expect its installation to be received favorably by the public and regulatory agencies. Although the project was well received by regulatory agencies, on public group (Save the Dunes Council) was initially concerned since the project is located adjacent to the Indiana Dunes National Lakeshore. The purpose of this paper is to describe the project team's experiences in obtaining permits/approvals from regulatory agencies and in dealing with the public. 1 ref., 1 fig., 2 tabs

  10. Design of CO{sub 2} absorption plant for recovery of CO{sub 2} from flue gases of gas turbine

    Energy Technology Data Exchange (ETDEWEB)

    Mofarahi, Masoud [Chemical Engineering Department, Persian Gulf University, Boushehr (Iran); Khojasteh, Yaser; Khaledi, Hiwa; Farahnak, Arsalan [Delta Consultant Engineering Group, Tehran (Iran)

    2008-08-15

    The ongoing human-induced emission of carbon dioxide (CO{sub 2}) threatens to change the earth's climate. A major factor in global warming is CO{sub 2} emission from thermal power plants, which burn fossil fuels. One possible way of decreasing CO{sub 2} emissions is to apply CO{sub 2} removal, which involves recovering of CO{sub 2} from energy conversion processes. This study is focused on recovery of CO{sub 2} from gas turbine exhaust of Sarkhun gas refinery power station. The purpose of this study is to recover the CO{sub 2} with minimum energy requirement. Many of CO{sub 2} recovery processes from flue gases have been studied. Among all CO{sub 2} recovery processes which were studied, absorption process was selected as the optimum one, due to low CO{sub 2} concentration in flue gas. The design parameters considered in this regard, are: selection of suitable solvent, solvent concentration, solvent circulation rate, reboiler and condenser duty and number of stages in absorber and stripper columns. In the design of this unit, amine solvent such as, diethanolamine (DEA), diglycolamine (DGA), methyldiethanolamine (MDEA), and monoethanolamine (MEA) were considered and the effect of main parameters on the absorption and stripping columns is presented. Some results with simultaneous changing of the design variables have been obtained. The results show that DGA is the best solvent with minimum energy requirement for recovery of CO{sub 2} from flue gases at atmospheric pressure. (author)

  11. GE`s worldwide experience with IFO based gypsum producing flue gas desulfurization systems

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, A. [GE Environmental Systems, Lebanon, PA (United States)

    1994-12-31

    The In-Situ Forced Oxidation (IFO) process to produce gypsum in a commercial scale flue gas desulfurization (FGD) system was first demonstrated by GE Environmental Systems in 1980 at the Monticello Generating Station of Texas Utilities. Since then, the IFO technology developed and demonstrated by GE has become the industry standard and is used extensively on a world-wide basis to produce both commercial and disposable-grade gypsum. The paper gives an overview of the development, demonstration, commercial design and current status of the IFO technology.

  12. Operational improvement to the flue gas cleaning system in radioactive waste incineration facilities

    International Nuclear Information System (INIS)

    Zheng Bowen; Li Xiaohai; Wang Peiyi

    2012-01-01

    After years of operation, some problems, such as corrosion and waste water treatment, have been found in the first domestic whole-scale radioactive waste incineration facility. According to the origin of the problems, the flue gas cleaning system has been optimized and improved in terms of technical process, material and structure. It improves the operational stability, extends the equipment life-time, and also reduces the amount of secondary waste. In addition, as major sources of problems, waste management, operational experiences and information exchange deserve more attention. (authors)

  13. Experimental study of swirl flow patterns in Gas Conditioning Tower at various entry conditions

    DEFF Research Database (Denmark)

    Jinov, Andrei A.; Larsen, Poul Scheel

    1999-01-01

    In a gas conditioning tower hot flue gas with relatively high dust loads is cooled by injecting water spray near the top. For satisfactory operation wet particles should be kept off walls and all water should have evaporated to yield a uniformly cooled flow before it reaches the bottom of the tower...

  14. Advanced separation technology for flue gas cleanup. Quarterly technical report No. 11, October 1994--December 1994

    Energy Technology Data Exchange (ETDEWEB)

    Bhown, A.S.; Alvarado, D.; Pakala, N. [and others

    1994-12-01

    The objective of this work is to develop a novel system for regenerable SO{sub 2} and NO{sub x} scrubbing of flue gas that focuses on (a) a novel method for regeneration of spent SO{sub 2} scrubbing liquor and (b) novel chemistry for reversible absorption of NO{sub x}. In addition, high efficiency hollow fiber contactors (HFC) are proposed as the devices for scrubbing the SO{sub 2} and NO{sub x} from the flue gas. The system will be designed to remove more than 95% of the SO{sub x} and more than 75% of the NO{sub x} from flue gases typical of pulverized coal-fired power plants at a cost that is at least 20% less than combined wet limestone scrubbing of SO{sub x} and selective catalytic reduction of NO{sub x}. In addition, the process will make only marketable byproducts, if any (no waste streams). The major cost item in existing technology is capital investment. Therefore, our approach is to reduce the capital cost by using high efficiency hollow fiber devices for absorbing and desorbing the SO{sub 2} and NO{sub x}. We will also introduce new process chemistry to minimize traditionally well-known problems with SO{sub 2} and NO{sub x} absorption and desorption. For example, we will extract the SO{sub 2} from the aqueous scrubbing liquor into an oligomer of dimethylaniline to avoid the problem of organic liquid losses in the regeneration of the organic liquid.

  15. Characterisation of the interaction between liquid film and flue gas flow at walls and internals in FGD scrubbers; Beschreibung der gegenseitigen Beeinflussung von Fluessigkeitsschicht und Rauchgasstroemung an Waenden und internen Einbauten in REA-Waeschern

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, Mario [Technische Univ. Dortmund (Germany). Lehrstuhl Mechanische Verfahrenstechnik; Fahlenkamp, Hans

    2012-07-01

    The VGB Research Project 'Characterisation of the interaction between liquid film and flue gas flow at walls and internals in FGD scrubbers' covers the droplet wall interaction in flue gas scrubbers. In the context of optimised FGD design, especially in fulfilling the increasing requirements on the conventional flue gas treatment by the CCS design, a better understanding of the flow behaviour near the wall is crucial. Within the framework of the research project an experimental setup is designed, built up and run. (orig.)

  16. Flue gas desulfurization: Physicochemical and biotechnological approaches

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, R.A.; Biswas, R.; Chakrabarti, T.; Devotta, S. [National Environmental Engineering Research Institute, Nagpur (India)

    2005-07-01

    Various flue gas desulfurization processes - physicochemical, biological, and chemobiological - for the reduction of emission of SO{sub 2} with recovery of an economic by-product have been reviewed. The physicochemical processes have been categorized as 'once-through' and 'regenerable.' The prominent once-through technologies include wet and dry scrubbing. The wet scrubbing technologies include wet limestone, lime-inhibited oxidation, limestone forced oxidation, and magnesium-enhanced lime and sodium scrubbing. The dry scrubbing constitutes lime spray drying, furnace sorbent injection, economizer sorbent injection, duct sorbent injection, HYPAS sorbent injection, and circulating fluidized bed treatment process. The regenerable wet and dry processes include the Wellman Lord's process, citrate process, sodium carbonate eutectic process, magnesium oxide process, amine process, aqueous ammonia process, Berglau Forchung's process, and Shell's process. Besides these, the recently developed technologies such as the COBRA process, the OSCAR process, and the emerging biotechnological and chemobiological processes are also discussed. A detailed outline of the chemistry, the advantages and disadvantages, and the future research and development needs for each of these commercially viable processes is also discussed.

  17. The combined effect of thermodynamic promoters tetrahydrofuran and cyclopentane on the kinetics of flue gas hydrate formation

    DEFF Research Database (Denmark)

    Daraboina, Nagu; von Solms, Nicolas

    2015-01-01

    ) hydrate formation using a rocking cell apparatus. Hydrate formation and decomposition kinetics were investigated by constant cooling (hydrate nucleation temperature) and isothermal (hydrate nucleation time) methods. Improved (synergistic) hydrate formation kinetics (hydrate nucleation and growth) were...... of these two promoters is favorable both thermodynamically and kinetically for hydrate formation from flue gas....

  18. Utilization of flue gas for cultivation of microalgae (Chlorella sp.) in an outdoor open thin-layer photobioreactor

    Czech Academy of Sciences Publication Activity Database

    Doucha, Jiří; Straka, F.; Lívanský, Karel

    2005-01-01

    Roč. 17, - (2005), s. 403-412 ISSN 0921-8971 R&D Projects: GA ČR GV104/97/S055; GA ČR GA104/02/0410 Institutional research plan: CEZ:AV0Z50200510 Keywords : microalgae * flue gas * carbon dioxide Subject RIV: EE - Microbiology, Virology Impact factor: 0.992, year: 2005

  19. Dew point measurements of flue gases in steam generators with brown coal combustion

    Energy Technology Data Exchange (ETDEWEB)

    Schinkel, W.

    1980-01-01

    This paper examines empirical data on sulfuric acid condensation and resulting internal corrosion in brown coal fired steam generators. Due to the high sulfur content in brown coal (0.5% to 5.0%) and relative short duration of the gases in the combustion chamber the concentrations of sulfur trioxide present in the flue gases can condense at the heat exchange surfaces of the steam generators. A number of diagrams show sulfuric acid dew point temperatures depending on brown coal sulfur content, the influence of combustion air supply on the dew point, and condensing speed and the rate of corrosion in relation to different heat exchange surface temperatures. The conclusion is made that a five-fold increase in corrosion can be caused by a 10 K higher flue gas dew point, a 5 K cooling of heating surfaces can also cause heavy corrosion at a certain dew point. Maximum corrosion results at 20 to 50 K differences between flue gas dew point and heat exchange surfaces. Optimum operation of steam generators with minimal internal corrosion requires the consideration of flue gas and heating surface temperatures as well as flue gas sulfur acid dew points. (10 refs.) (In German)

  20. The design of the extraction window of high power electron accelerator used in flue gas desulfurization

    International Nuclear Information System (INIS)

    He Tongqi; Chinese Academy of Sciences, Shanghai; Hu Wei; Sun Guangkui; Shi Weiguo; Li Minxi; Zhang Yutian; Pu Gengqiang

    2007-01-01

    Recently, the pollution caused by industrial exhaust gas, especially, the air pollution and acid rain resulting from the sulfur of exhaust gas, is increasingly drawing people's attention. The flue gas desulfurization by electron beam produced by high-power electron accelerator has the characteristics of high efficiency and non-secondary contamination. As one of the most pivotal part of accelerator, the service lifetime of this extraction window directly effects the stable operation of the device. In this paper, a brief review is given to summarize the advantages, material selecting, structure, replacing, maintaining of the extraction window of high-power electron accelerator developed by SINAP. (authors)

  1. The production and utilization of by-product agricultural fertilizer from flue gases

    International Nuclear Information System (INIS)

    Frank, N.W.; Hirano, S.

    1991-01-01

    The electron-beam process is one of the most effective methods for removing SO 2 and NO x from industrial flue gases and producing a usable by-product. This flue gas treatment consists of adding a small amount of ammonia to the flue gas and irradiating the gas by means of an electron beam. This causes reactions which convert SO 2 and NO x to ammonium sulfate and ammonium nitrate. These salts are then collected from the flue gas by conventional collectors, such as a baghouse or electrostatic precipitator. This paper will describe the potential for production of the fertilizer and will analyze the market potential and consumption of the by-product. A principal focus of the work is an analysis and quantification of the major large-scale, growing and profitable markets for utility solid wastes that can be generated in the form of agricultural fertilizer. Cost study data is arranged to define the impact of commercial by-product field and revenue on the economics of full scale SO 2 and NO x emission reduction activity

  2. Corrosion in the Flue Gas Cleaning System of a Biomass-Fired Power Plant

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Olesen, R. E.; Gensmann, P.

    2017-01-01

    After only a few years operation, corrosiondamage was observed in the flue gas cleaning system of abiomass power plant. The corrosion was on the lower partof the gas/gas heat exchanger fabricated from A242weathering steel, where UNS S31600 bolts were used toattach sealing strips to the rotor. Thick...... iron oxides (up to5 mm) had formed on the weathering steel, and theseoxides also contained chlorine and sulfur. In this area of theheat exchanger, weathering steel has not had the optimalwet/dry cycles required to achieve a protective oxide. Dueto the thick growing oxide on the rotor, the UNS S31600......bolts were under stress and this together with the presenceof accumulated chlorine between the sealing strips andbolts resulted in stress corrosion cracking and rupture. Inaddition, Zn-K-Cl deposits were agglomerated in the ductafter the DeNOx unit. Zn was also a constituent of corrosionproducts...

  3. CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS

    International Nuclear Information System (INIS)

    David A. Green; Brian S. Turk; Raghubir P. Gupta; Douglas P. Harrison; Ya Liang

    2001-01-01

    The objective of this project is to develop a simple, inexpensive process to separate CO(sub 2) as an essentially pure stream from a fossil fuel combustion system using a regenerable, sodium-based sorbent. The sorbent being used in this project is sodium carbonate which is converted to sodium bicarbonate, ''baking soda,'' through reaction with carbon dioxide and water vapor. Sodium bicarbonate is regenerated to sodium carbonate when heated, producing a nearly pure CO(sub 2) stream after condensation of water vapor. Testing conducted previously confirmed that the reaction rate and achievable CO(sub 2) capacity of sodium carbonate decreased with increasing temperature, and that the global rate of reaction of sodium carbonate to sodium bicarbonate increased with an increase in both CO(sub 2) and H(sub 2)O concentrations. Energy balance calculations indicated that the rate of heat removal from the particle surface may determine the reaction rate for a particular particle system. This quarter, thermogravimetric analyses (TGA) were conducted which indicated that calcination of sodium bicarbonate at temperatures as high as 200 C did not cause a significant decrease in activity in subsequent carbonation testing. When sodium bicarbonate was subjected to a five cycle calcination/carbonation test, activity declined slightly over the first two cycles but was constant thereafter. TGA tests were also conducted with two other potential sorbents. Potassium carbonate was found to be less active than sodium carbonate, at conditions of interest in preliminary TGA tests. Sodium carbonate monohydrate showed negligible activity. Testing was also conducted in a 2-inch internal diameter quartz fluidized-bed reactor system. A five cycle test demonstrated that initial removals of 10 to 15 percent of the carbon dioxide in a simulated flue gas could be achieved. The carbonation reaction proceeded at temperatures as low as 41 C. Future work by TGA and in fixed-bed, fluidized-bed, and transport

  4. CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS

    Energy Technology Data Exchange (ETDEWEB)

    David A. Green; Brian S. Turk; Raghubir P. Gupta; Douglas P. Harrison; Ya Liang

    2001-10-01

    The objective of this project is to develop a simple, inexpensive process to separate CO{sub 2} as an essentially pure stream from a fossil fuel combustion system using a regenerable, sodium-based sorbent. The sorbent being used in this project is sodium carbonate which is converted to sodium bicarbonate, ''baking soda,'' through reaction with carbon dioxide and water vapor. Sodium bicarbonate is regenerated to sodium carbonate when heated, producing a nearly pure CO{sub 2} stream after condensation of water vapor. Testing conducted previously confirmed that the reaction rate and achievable CO{sub 2} capacity of sodium carbonate decreased with increasing temperature, and that the global rate of reaction of sodium carbonate to sodium bicarbonate increased with an increase in both CO{sub 2} and H{sub 2}O concentrations. Energy balance calculations indicated that the rate of heat removal from the particle surface may determine the reaction rate for a particular particle system. This quarter, thermogravimetric analyses (TGA) were conducted which indicated that calcination of sodium bicarbonate at temperatures as high as 200 C did not cause a significant decrease in activity in subsequent carbonation testing. When sodium bicarbonate was subjected to a five cycle calcination/carbonation test, activity declined slightly over the first two cycles but was constant thereafter. TGA tests were also conducted with two other potential sorbents. Potassium carbonate was found to be less active than sodium carbonate, at conditions of interest in preliminary TGA tests. Sodium carbonate monohydrate showed negligible activity. Testing was also conducted in a 2-inch internal diameter quartz fluidized-bed reactor system. A five cycle test demonstrated that initial removals of 10 to 15 percent of the carbon dioxide in a simulated flue gas could be achieved. The carbonation reaction proceeded at temperatures as low as 41 C. Future work by TGA and in fixed

  5. Effects of water vapor on flue gas conditioning in the electric fields with corona discharge

    Energy Technology Data Exchange (ETDEWEB)

    Liqiang, QI, E-mail: qi_liqiang@163.com; Yajuan, Zhang

    2013-07-15

    Highlights: • The influence mechanism of water vapor humidification on SO{sub 2} oxidation was analyzed. •The effects of water vapor on the specific resistance in fly ash in ESPs were reported. • The effects of water vapor on the size distribution and specific surface area of fly ash were discussed. • The adhesive characteristic of fly ash in different water vapor was experimented. -- Abstract: Sulfur dioxide (SO{sub 2}) removal via pulsed discharge nonthermal plasma in the absence of ammonia was investigated to determine how electrostatic precipitators (ESPs) can effectively collect particulate matter less than 2.5 μm in diameter from flue gas. SO{sub 2} removal increased as water vapor concentration increased. In a wet-type plasma reactor, directing a gas-phase discharge plasma toward the water film surface significantly enhanced the liquid-phase oxidation of HSO{sub 3}{sup −} to SO{sub 4}{sup 2−}. Comparisons of various absorbents revealed that the hydroxyl radical is a key factor in plasma-induced liquid-phase reactions. The resistivity, size distribution, and cohesive force of fly ash at different water vapor contents were measured using a Bahco centrifuge, which is a dust electrical resistivity test instrument, as well as a cohesive force test apparatus developed by the researchers. When water vapor content increased by 5%, fly ash resistivity in flue gas decreased by approximately two orders of magnitude, adhesive force and size increased, and specific surface area decreased. Therefore, ESP efficiency increased.

  6. Biomass gasification hot gas cleanup for power generation

    Energy Technology Data Exchange (ETDEWEB)

    Wiant, B.C.; Bachovchin, D.M. [Westinghouse Electric Corp., Orlando, FL (United States); Carty, R.H.; Onischak, M. [Institute of Gas Technology, Chicago, IL (United States); Horazak, D.A. [Gilbert/Commonwealth, Reading, PA (United States); Ruel, R.H. [The Pacific International Center for High Technology Research, Honolulu, HI (United States)

    1993-12-31

    In support of the US Department of Energy`s Biomass Power Program, a Westinghouse Electric led team consisting of the Institute of Gas Technology (IGT), Gilbert/Commonwealth (G/C), and the Pacific International Center for High Technology Research (PICHTR), is conducting a 30 month research and development program. The program will provide validation of hot gas cleanup technology with a pressurized fluidized bed, air-blown, biomass gasifier for operation of a gas turbine. This paper discusses the gasification and hot gas cleanup processes, scope of work and approach, and the program`s status.

  7. A plug flow model for chemical reactions and aerosol nucleation and growth in an alkali-containing flue gas

    DEFF Research Database (Denmark)

    Christensen, K. A.; Livbjerg, Hans

    2000-01-01

    multicomponent growth models are treated. The local gas phase composition is determined from a gas phase chemical equilibrium calculation combined with finite reaction rate kinetics for slower reactions. The model is useful in the analysis of boiler operation with respect to the formation of particles, HCl, SO2......The paper presents a numerical model for the simulation of gas to particle conversion and the chemical changes during cooling of a flue gas from the combustion of fuels rich in volatile alkali species. For the homogeneous nucleation of alkali species the model uses the classical theory modified...

  8. Measurements to determine the sulfuric acid dew point and the SO sub 3 concentration in flue gas of power plant vessels. Messungen zur Bestimmung des Saeuretaupunktes und der SO sub 3 -Konzentration im Rauchgas von Kraftwerkskesseln

    Energy Technology Data Exchange (ETDEWEB)

    Derichs, W.; Menden, W. (RWE Energie AG, Bergheim (Germany)); Ebel, P.K. (Apparatebau Hundsbach GmbH, Baden-Baden (Germany))

    1990-01-01

    Among the customary methods of dew point determination, the technique of recording the increase in conductivity between two electrodes at the moment of acid condensing onto them, and measuring at the same time the temperature of the sensor, is appropriate to determine the sulfuric acid dew point in dust-laden flue gas. By means of the sensitivity of a newly developed sensor, the accuracy of the measurement method could be improved to such an extent that also low acid dew points and rapid changes can be recorded reliably. Measurements have shown that the acid dew point primarily depends on the SO{sub 3} content which is substantially determined by the sulfur content of the fuel and the type of flue gas ducts. Further influential quantities include flue gas humidity, air surplus, other gaseous flue gas components such as HCl and HF, as well as the quantity, composition and temperature-dependent adsorption capability of the flue dusts. (orig./BBR).

  9. Optimising the flow characteristic of a coke-oven flue-gas valve by means of Computational Fluid Dynamics (CFD); Stroemungsoptimierung eines Abgasventils von Koksoefen durch Computational Fluid Dynamics (CFD)

    Energy Technology Data Exchange (ETDEWEB)

    Hiller, R.; Cremer, I.; Bertling, J. [Fraunhofer-Institut fuer Umwelt-, Sicherheits- und Energietechnik UMSICHT, Oberhausen (Germany); Dittie, J.; Kim, R.; Reinke, M. [Krupp Uhde GmbH, Dortmund (Germany)

    1999-06-01

    In coke-oven operations flue-gas valves are used to switch the regenerator function from rich gas firing to lean gas firing. Compared with the simple geometry of the other parts of the flow path, which comprise flues and regenerators, the narrow and winding passages of the flue-gas valves give rise to relatively high losses in pressure. Without the construction of high (and therefore expensive) chimneys, this means that operating problems may well arise due the inadequate suction capacity. The project focused on the theoretical and experimental analysis of a coke-oven flue-gas valve. The primary aim was to reduce the pressure drop through the valve without modifying its external geomerty. The internal flow characteristics created by different valve geometries under a variety of operating conditions were simulated using the commercial CFD code Fluent/UNS, which provided velocity and pressure distributions. A half-scale model valve was constructed in order to characterise the internal flow behaviour by pressure measurement. (orig.) [Deutsch] In einem bei Fraunhofer UMSICHT durchgefuehrten Projekt wurde die Stroemung in einem Abgasventil eines Koksofens, das der Umschaltung der Regeneratorfunktion von Starkgasbeheizung auf Schwachgasbeheizung dient, theoretisch und experimentell untersucht, um die relativ hohen Druckverluste zu vermindern. Vorgeschlagen wurde eine Modifikation der Abgasventilkonstruktion, die den Druckverlust um mehr als das Zehnfache vermindert und zu einer baulichen Vereinfachung des Ventils fuehrt. (orig.)

  10. Recovery of flue gas energy in heat-integrated gasification combined cycle (IGCC) power plants using the contact economizer system

    CSIR Research Space (South Africa)

    Madzivhandila, VA

    2011-03-01

    Full Text Available (flue gas) stream of a heat-integrated gasification combined cycle (IGCC) design of the Elcogas plant adopted from previous studies. The underlying support for this idea was the direct relationship between efficiency of the IGCC and the boiler feedwater...

  11. CO₂ Capture Membrane Process for Power Plant Flue Gas

    Energy Technology Data Exchange (ETDEWEB)

    Toy, Lora [Research Triangle Inst. International, Research Triangle Park, NC (United States); Kataria, Atish [Research Triangle Inst. International, Research Triangle Park, NC (United States); Gupta, Raghubir [Research Triangle Inst. International, Research Triangle Park, NC (United States)

    2012-04-01

    Because the fleet of coal-fired power plants is of such importance to the nation's energy production while also being the single largest emitter of CO₂, the development of retrofit, post-combustion CO₂ capture technologies for existing and new, upcoming coal power plants will allow coal to remain a major component of the U.S. energy mix while mitigating global warming. Post-combustion carbon capture technologies are an attractive option for coal-fired power plants as they do not require modification of major power-plant infrastructures, such as fuel processing, boiler, and steam-turbine subsystems. In this project, the overall objective was to develop an advanced, hollow-fiber, polymeric membrane process that could be cost-effectively retrofitted into current pulverized coal-fired power plants to capture at least 90% of the CO₂ from plant flue gas with 95% captured CO₂ purity. The approach for this project tackled the technology development on three different fronts in parallel: membrane materials R&D, hollow-fiber membrane module development, and process development and engineering. The project team consisted of RTI (prime) and two industrial partners, Arkema, Inc. and Generon IGS, Inc. Two CO₂-selective membrane polymer platforms were targeted for development in this project. For the near term, a next-generation, high-flux polycarbonate membrane platform was spun into hollow-fiber membranes that were fabricated into both lab-scale and larger prototype (~2,200 ft²) membrane modules. For the long term, a new fluoropolymer membrane platform based on poly(vinylidene fluoride) [PVDF] chemistry was developed using a copolymer approach as improved capture membrane materials with superior chemical resistance to flue-gas contaminants (moisture, SO₂, NOx, etc.). Specific objectives were: - Development of new, highly chemically resistant, fluorinated polymers as membrane materials with minimum selectivity of 30 for CO₂ over N₂ and CO

  12. Effects of magnetic fields on improving mass transfer in flue gas desulfurization using a fluidized bed

    Science.gov (United States)

    Zhang, Qi; Gui, Keting; Wang, Xiaobo

    2016-02-01

    The effects of magnetic fields on improving the mass transfer in flue gas desulfurization using a fluidized bed are investigated in the paper. In this research, the magnetically fluidized bed (MFB) is used as the reactor in which ferromagnetic particles are fluidized with simulated flue gas under the influence of an external magnetic field. Lime slurry is continuously sprayed into the reactor. As a consequence, the desulfurization reaction and the slurry drying process take place simultaneously in the MFB. In this paper, the effects of ferromagnetic particles and external magnetic fields on the desulphurization efficiency are studied and compared with that of quartz particles as the fluidized particles. Experimental results show that the ferromagnetic particles not only act as a platform for lime slurry to precipitate on like quartz particles, but also take part in the desulfurization reaction. The results also show that the specific surface area of ferromagnetic particles after reaction is enlarged as the magnetic intensity increases, and the external magnetic field promotes the oxidation of S(IV), improving the mass transfer between sulphur and its sorbent. Hence, the efficiency of desulphurization under the effects of external magnetic fields is higher than that in general fluidized beds.

  13. Electrospun cerium-based TiO2 nanofibers for photocatalytic oxidation of elemental mercury in coal combustion flue gas.

    Science.gov (United States)

    Wang, Lulu; Zhao, Yongchun; Zhang, Junying

    2017-10-01

    Photocatalytic oxidation is an attractive method for Hg-rich flue gas treatment. In the present study, a novel cerium-based TiO 2 nanofibers was prepared and selected as the catalyst to remove mercury in flue gas. Accordingly, physical/chemical properties of those nanofibers were clarified. The effects of some important parameters, such as calcination temperature, cerium dopant content and different illumination conditions on the removal of Hg 0 using the photocatalysis process were investigated. In addition, the removal mechanism of Hg 0 over cerium-based TiO 2 nanofibers focused on UV irradiation was proposed. The results show that catalyst which was calcined at 400 °C exhibited better performance. The addition of 0.3 wt% Ce into TiO 2 led to the highest removal efficiency at 91% under UV irradiation. As-prepared samples showed promising stability for long-term use in the test. However, the photoluminescence intensity of nanofibers incorporating ceria was significantly lower than TiO 2 , which was attributed to better photoelectron-hole separation. Although UV and O 2 are essential factors, the enhancement of Hg 0 removal is more obviously related to the participation of catalyst. The coexistence of Ce 3+ and Ce 4+ , which leads to the efficient oxidation of Hg 0 , was detected on samples. Hg 2+ is the final product in the reaction of Hg 0 removal. As a consequence, the emissions of Hg 0 from flue gas can be significantly suppressed. These indicate that combining photocatalysis technology with cerium-based TiO 2 nanofibers is a promising strategy for reducing Hg 0 efficiently. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Status of the development of hot gas ducts for HTRs

    International Nuclear Information System (INIS)

    Stehle, H.; Klas, E.

    1984-01-01

    In the PNP nuclear process heat system the heat generated in the helium cooled core is transferred to the steam reformer and to the successive steam generator or to the intermediate heat exchanger by the primary helium via suitable hot gas ducts. The heat is carried over to the steam gasifier by the intermediate heat exchanger and a secondary helium loop. In both the primary and the secondary loop, the hot gas ducts are internally insulated by a ceramic fibre insulation to protect the support tube and the pressure housing from the high helium temperatures. A graphite hot gas liner will be used for the coaxial primary duct with an annular gap between support tube and pressure shell for the cold gas counterflow. A metallic hot gas liner will be installed in the secondary duct

  15. A study on removal of elemental mercury in flue gas using fenton solution

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yangxian; Wang, Yan; Wang, Qian; Pan, Jianfeng [School of Energy and Power Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013 (China); Zhang, Yongchun [Jiangsu Province Special Equipment Safety Supervision Inspection Institute (Branch of Wuxi), Wuxi 214000 (China); Zhou, Jianfei [School of Energy and Power Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013 (China); Zhang, Jun [Key Laboratory of Energy Thermal Conversion and Control of Ministry of Education, Southeast University, Nanjing 210096 (China)

    2015-07-15

    Highlights: • A novel technique on oxidation of Hg{sup 0} using Fenton was proposed. • The effects of several process parameters on Hg{sup 0} removal were studied. • Products and ·OH in solution were detected. • Reaction mechanism of Hg{sup 0} removal was studied. • Simultaneous removal of Hg{sup 0}, NO and SO{sub 2} was also studied. - Abstract: A novel technique on oxidation-separation of elemental mercury (Hg{sup 0}) in flue gas using Fenton solution in a bubbling reactor was proposed. The effects of several process parameters (H{sub 2}O{sub 2} concentration, Hg{sup 0} inlet concentration, Fe{sup 2+} concentration, solution temperature, solution pH, gas flow) and several flue gas components (NO, SO{sub 2}, O{sub 2}, CO{sub 2}, inorganic ions and particulate matters on Hg{sup 0} removal were studied. The results indicate that H{sub 2}O{sub 2} concentration, Fe{sup 2+} concentration, solution pH and gas flow have great effects on Hg{sup 0} removal. Solution temperature, Hg{sup 0}, NO, SO{sub 2}, CO{sub 3}{sup 2−} and HCO{sub 3}{sup −} concentrations also have significant effects on Hg{sup 0} removal. However, Cl{sup −}, SO{sub 4}{sup 2−}, NO{sub 3}{sup −}, O{sub 2} and CO{sub 2} concentrations only have slight effects on Hg{sup 0} removal. Furthermore, reaction mechanism of Hg{sup 0} removal and simultaneous removal process of Hg{sup 0}, NO and SO{sub 2} were also studied. Hg{sup 0} is removed by oxidation of ·OH and oxidation of H{sub 2}O{sub 2}. The simultaneous removal efficiencies of 100% for SO{sub 2}, 100% for Hg{sup 0} and 88.3% for NO were obtained under optimal test conditions. The results demonstrated the feasibility of Hg{sup 0} removal and simultaneous removal of Hg{sup 0}, SO{sub 2} and NO using Fenton solution in a bubbling reactor.

  16. Study on removal of elemental mercury from simulated flue gas over activated coke treated by acid

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Jinfeng [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control, Hunan University, Ministry of Education, Changsha 410082 (China); Li, Caiting, E-mail: ctli@hnu.edu.cn [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control, Hunan University, Ministry of Education, Changsha 410082 (China); Zhao, Lingkui; Zhang, Jie; Song, Jingke; Zeng, Guangming; Zhang, Xunan; Xie, Yine [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control, Hunan University, Ministry of Education, Changsha 410082 (China)

    2015-02-28

    Highlights: • HClO{sub 4} treated AC was developed for effective Hg{sup 0} removal from simulated flue gas. • The exceptional effect of SO{sub 2} on Hg{sup 0} removal by AC{sub 4.5} was discussed. • Possible reaction mechanism of Hg{sup 0} removal over AC{sub 4.5} was put forward. - Abstract: This work addressed the investigation of activated coke (AC) treated by acids. Effects of AC samples, modified by ether different acids (H{sub 2}SO{sub 4}, HNO{sub 3} and HClO{sub 4}) or HClO{sub 4} of varied concentrations, on Hg{sup 0} removal were studied under simulated flue gas conditions. In addition, effects of reaction temperature and individual flue gas components including O{sub 2}, NO, SO{sub 2} and H{sub 2}O were discussed. In the experiments, Brunauer–Emmett–Teller (BET), X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR) were applied to explore the surface properties of sorbents and possible mechanism of Hg{sup 0} oxidation. Results showed that AC sample treated by HClO{sub 4} of 4.5 mol/L exhibited maximum promotion of efficiency on Hg{sup 0} removal at 160 °C. NO was proved to be positive in the removal of Hg{sup 0}. And SO{sub 2} displayed varied impact in capturing Hg{sup 0} due to the integrated reactions between SO{sub 2} and modified AC. The addition of O{sub 2} could improve the advancement further to some extent. Besides, the Hg{sup 0} removal capacity had a slight declination when H{sub 2}O was added in gas flow. Based on the analysis of XPS and FTIR, the selected sample absorbed Hg{sup 0} mostly in chemical way. The reaction mechanism, deduced from results of characterization and performance of AC samples, indicated that Hg{sup 0} could firstly be absorbed on sorbent and then react with oxygen-containing (C−O) or chlorine-containing groups (C−Cl) on the surface of sorbent. And the products were mainly in forms of mercuric chloride (HgCl{sub 2}) and mercuric oxide (HgO)

  17. Hydroquinone and quinone-grafted porous carbons for highly selective CO2 capture from flue gases and natural gas upgrading

    NARCIS (Netherlands)

    Wang, J.; Krishna, R.; Yang, J.; Deng, S.

    2015-01-01

    Hydroquinone and quinone functional groups were grafted onto a hierarchical porous carbon framework via the Friedel-Crafts reaction to develop more efficient adsorbents for the selective capture and removal of carbon dioxide from flue gases and natural gas. The oxygen-doped porous carbons were

  18. Investigations on electron beam flue gas treatment held in the Institute of Nuclear Chemistry and Technology

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Iller, E.; Zimek, Z.; Licki, J.

    1992-01-01

    Two different research installations have been built. The first one, laboratory unit has a flow capacity of approx. 400 Nm 3 /h of flue gas from two gas fired boilers. The composition of gas can be adjusted. An irradiator, accelerator ILU-6, is used with electron beam energy in the range 600-1000 keV. The unit is mostly used for aerosol formation and filtration research. This laboratory installation is being adapted for electron beam/microwave combined gas molecule excitation. The second unit, a pilot with a plant of flow rate up to 20 000 Nm 3 /h has been constructed in EPS Kaweczyn. Pit coal is used as a fuel in a boiler from which flue gas is purified. Two accelerators, ELW-3, of beam power 40-50 kW and electrons energy 700 keV are applied. The arrangement of accelerators in series allows cascade, step by step gas mixture irradiation. The installation is equipped in a spray cooler, ammonia dosage system and bag filter. The irradiation/reaction part of the plant was put in operation in April 1991. Separately, laboratory research on grain bed aerosol filtration is performed to study the possibility of such filtration unit as a prefilter application. Agriculture tests of the byproduct have been performed. Two types of the byproduct with and without additive were tested. Comparative vegetation tests have shown that application of the pure product gives similar results as application of market fertilizer - ammonia sulfate. The elemental analysis have shown that content of the heavy metals do not exceed acceptable value. For both systems dosimetric measurements were performed. The electron penetration depth and dose distribution profiles were established. The results of preliminary tests both laboratory and pilot plant units have proved high efficiency of SO 2 and NO X removal. (J.P.N.)

  19. Pilot-scale demonstration of the OSCAR process for high-temperature multipollutant control of coal combustion flue gas, using carbonated fly ash and mesoporous calcium carbonate

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, H.; Thomas, T.J.; Park, A.H.A.; Iyer, M.V.; Gupta, P.; Agnihotri, R.; Jadhav, R.A.; Walker, H.W.; Weavers, L.K.; Butalia, T.; Fan, L.S. [Ohio State University, Columbus, OH (United States)

    2007-07-15

    A pilot-scale study of the Ohio State Carbonation Ash Reactivation (OSCAR) process was performed to demonstrate the reactivity of two novel calcium-based sorbents toward sulfur and trace heavy metal (arsenic, selenium, and mercury) capture in the furnace sorbent injection (FSI) mode on a 0.365 m{sup 3}/s slipstream of a bituminous coal-fired stoker boiler. The sorbents were synthesized by bubbling CO{sub 2} to precipitate calcium carbonate (a) from the unreacted calcium present in the lime spray dryer ash and (b) from calcium hydroxide slurry that contained a negatively charged dispersant. The heterogeneous reaction between these sorbents and SO{sub 2} gas occurred under entrained flow conditions by injecting fine sorbent powders into the flue gas slipstream. The reacted sorbents were captured either in a hot cyclone (about 650{sup o}C) or in the relatively cooler downstream baghouse (about 230{sup o}C). The baghouse samples indicated about 90% toward sulfation and captured arsenic, selenium and mercury to 800 ppmw, 175 ppmw and 3.6 ppmw, respectively.

  20. Online measurements of non-organic components in flue gas; Online-maetning av oorganiska komponenter i roekgas

    Energy Technology Data Exchange (ETDEWEB)

    Niklasson, Fredrik; Claesson, Frida; Haraldsson, Conny

    2010-03-15

    In combined heat and power plants firing biomass and waste, the power efficiency is generally limited by the steam temperature, which in turn is restricted by the fouling and corrosion caused by alkali chlorides. Such alkali induced problems usually increase with both temperature and concentrations of alkali chlorides. This work investigates the prospect of reducing the concentrations of alkali and zinc chlorides in the flue gas by the addition of SO{sub 2} in a fluidized bed (FB). Addition of HCl to the bed was also investigated in order to simulate high chlorine content in the fuel. The aim with the project is to determine the changes in the release of alkali and zinc compounds when adding HCl and SO{sub 2} in the combustion of waste pellets and straw pellets. The results are intended for plant owners as well as boiler manufacturers. The experiments were carried out in a FB-reactor fluidized with a gas mixture of air and nitrogen at 850 deg C. Single fuel pellets were added to the reactor after which the concentrations of various substances (mainly zinc and alkali metals) in the flue gas were measured using ICP-MS (Inductively Coupled Plasma - Mass Spectrometry). The waste fuel used was from Boraas (BEM). The results show that the addition of HCl into the reactor significantly increases the release of alkali and zinc compounds when burning a single waste pellets. Addition of solely SO{sub 2} to the combustion air shows no effect. When adding both HCl and SO{sub 2} there is a clear reduction of alkali and zinc release compared to when only HCl is added. This shows that the addition of SO{sub 2} decreases the release of alkali and zinc at high Cl-concentrations. However, the ICP-MS instrument only shows the total amount of alkali and zinc, not considering whether they are associated with chlorine or sulfur, thus the experiments do not provide all information on possible changes of the chemical composition of the fly ash. Within the present project, it is shown that

  1. Acid dispersion abatement: the use of flue gas desulphurisation in the UK

    Energy Technology Data Exchange (ETDEWEB)

    Longhurst, J.W.S.; Health, B.A.; Gibber, D.C. [Manchester Metropolitan University, Manchester (United Kingdom). Atmospheric Research and Information Centre, Dept. of Environmental and Geographical Sciences

    1995-12-31

    This paper reviews and evaluates the development of the UK flue gas desulphurisation (FGD) programme. This programme on establishment in 1986 represented a planned and coherent approach to acid deposition abatement which would progressively reduce emissions whilst maintaining the UK`s coal fired power generation capacity. It was anticipated that at least 12000 MW of electricity generating plant would be retrofitted with FGD. The programme has effectively been abandoned in favour of market based approach to emission control which sets the targets to be achieved but not the means. As a consequence the retrofitted capacity in 1995 is just 6000 MW. 17 refs., 1 tab.

  2. An innovative process for simultaneous removal of CO2 and SO2 from flue gas of a power plant by energy integration

    International Nuclear Information System (INIS)

    Yu, Y.S.; Li, Y.; Li, Q.; Jiang, J.; Zhang, Z.X.

    2009-01-01

    With the fast development of the society, the amount of carbon dioxide has been increased enormously in the atmosphere all over the world, which has already endangered the survival of human being. More and more people or organizations are studying new technologies to reduce the cost of capturing CO 2 . The recovery and sequestration of CO 2 from flue gas of the power plant is regarded as a feasible way to mitigate the greenhouse gas emissions. Therefore, the process of recovering carbon dioxide by chemical absorption with monoethanolamine (MEA) in industry was emphatically described in this paper. Based on energy integration, a coupled process was proposed which included MEA absorption of CO 2 and SO 2 , and the heat recovery from the flue gas's waste heat recovery unit and compressor inter-stage cooling unit. Compared the innovative process with an original process, 9% of thermal energy could be reduced in the new flowsheet. Meanwhile decarbonization and desulphurization could be carried on in the absorber simultaneously without the usual wet flue gas desulphurization (FGD) system. An exergy analysis model was established and validated by the literature data with a deviation less than 5.40%. The exergy results indicated that the exergy loss of the improved process was 15.48-20.75% less than that of the original one, which proved that the innovative process was reasonable and effective from the perspective of energy utilization.

  3. Metals in soil and runoff from a piedmont hayfield amended with broiler litter and flue gas desulfurization gypsum

    Science.gov (United States)

    Flue gas desulfurization gypsum (FGDG) from coal-fired power plants is available for agricultural use in many US regions. Broiler litter (BL) provides plant available N, P, and K but may be a source of unwanted arsenic (As), copper (Cu), and zinc (Zn). FGDG provides Ca and S and can reduce runoff lo...

  4. Mercury emission and plant uptake of trace elements during early stage of soil amendment using flue gas desulfurization materials.

    Science.gov (United States)

    A pilot-scale field study was carried out to investigate the distribution of Hg and other selected elements in the three potential mitigation pathways, i.e., emission to ambient air, uptake by surface vegetation (i.e., grass), and rainfall infiltration, after flue gas desulfurization (FGD) material ...

  5. Simulation studies of the influence of HCl absorption on the performance of a wet flue gas desulphurisation pilot plant

    DEFF Research Database (Denmark)

    Kiil, Søren; Nygaard, Helle; Johnsson, Jan Erik

    2002-01-01

    The mathematical model of Kiil et al, (Ind. Eng, Chem. Res. 37 (1998) 2792) for a wet flue gas desulphurisation (FGD) pilot plant was extended to include the simultaneous absorption of HCl. In contrast to earlier models for wet FGD plants, the inclusion of population balance equations...

  6. Evolution of Hot Gas in Elliptical Galaxies

    Science.gov (United States)

    Mathews, William G.

    2004-01-01

    This theory grant was awarded to study the curious nature, origin and evolution of hot gas in elliptical galaxies and their surrounding groups. Understanding the properties of this X-ray emitting gas has profound implications over the broad landscape of modern astrophysics: cosmology, galaxy formation, star formation, cosmic metal enrichment, galactic structure and dynamics, and the physics of hot gases containing dust and magnetic fields. One of our principal specific objectives was to interpret the marvelous new observations from the XMM and Chandru satellite X-ray telescopes.

  7. Treatment of waste water from flue gas cleaning; Behandlung von Abwasser der Rauchgasreinigung

    Energy Technology Data Exchange (ETDEWEB)

    Ogiermann, Klaus; Meyerhoff, Thomas [Berkefeld - VWS Deutschland GmbH, Celle (Germany); Hagen, Klaus [Berkefeld - VWS Deutschland GmbH, Bayreuth (Germany); Basabe, Juan Luis [HPD Process Engineering S.A., Bilbao (Spain); Vendrup, Michael [Krueger A/S, Soeborg (Denmark)

    2012-11-01

    Strict limits must be adhered to for treating waste water incurred during flue gas desulphurisation (FGD). One and two-stage precipitation processes have proven themselves in FGD waste water treatment. Metals can be removed with the MetClean {sup registered} process. Another option is evaporation. Waste water ZLD systems (Zero Liquid Discharge) recover, via a falling film evaporator with subsequent crystallisation, more than 98 % of the water and produce, aside from the condensate, only solid material that can be disposed of in landfill. A further development, named ZLD CoLD trademark, significantly reduces the investment and operating costs of this solution. (orig.)

  8. Collection and application of by-product formed in e-b flue gas treatment process

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Tyminski, B.; Zakrzewska-Trznadel, G.; Tokunaga, O.; Machi, S.

    1998-01-01

    In the e-b process SO 2 and NO x are converted into ammonium sulphate and ammonium nitrate, which condenses from gas phase in the form of submicrone particles. These salts are a valuable fertilizer and should be removed from cleaned gas. Bag filter, ESP and wet gravel bed filter were applied for collecting of salt particles in pilot plant facilities. Up to now ESP is considered to be the best filtration method of aerosols formed after irradiation of flue gas. Collected salts after granulation may be used as a fertilizer enriching soil in nitrogen and sulphur or as a component of mixed fertilizer. Analysis of by-products from different e-b pilot plants confirms that it does not contain any harmful substances like heavy metals and fulfill all standards for commercial fertilizers. Also field experiments show that the by-products have the same properties as a commercial fertilizer

  9. Adsorption and reaction mechanism of arsenic vapors over γ-Al2O3 in the simulated flue gas containing acid gases.

    Science.gov (United States)

    Hu, Hongyun; Chen, Dunkui; Liu, Huan; Yang, Yuhan; Cai, Hexun; Shen, Junhao; Yao, Hong

    2017-08-01

    Arsenic emission from fuel combustion and metal smelting flue gas causes serious pollution. Addition of sorbents is a promising way for the arsenic capture from high temperature flue gas. However, it is difficult to remove arsenic from SO 2 /HCl-rich flue gas due to the competitive reaction of the sorbents with arsenic and these acid gases. To solve this problem, arsenic adsorption over γ-Al 2 O 3 was studied in this work to evaluate its adsorption mechanism, resistance to acid gases as well as regeneration behavior. The results show that γ-Al 2 O 3 had good resistance to acid gases and the arsenic adsorption by γ-Al 2 O 3 could be effectively carried out at a wide temperature range between 573 and 1023 K. Nevertheless, adsorption at higher-temperature (like 1173 K) leaded to the decrease of surface area and the rearrangement of crystal structure of γ-Al 2 O 3 , reducing the active sites for arsenic adsorption. The adsorption of arsenic was confirmed to occur at different active sites in γ-Al 2 O 3 by forming various adsorbed species. Increasing temperature facilitated arsenic transformation into more stable chemisorbed As 3+ and As 5+ which were difficult to remove through thermal treatment regeneration. Fortunately, the regeneration of spent γ-Al 2 O 3 could be well performed using NaOH solution. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. The removal of alkali metals from hot gas

    Energy Technology Data Exchange (ETDEWEB)

    Orjala, M.; Haukka, P. (Valtion Teknillinen Tutkimuskeskus, Jyvaeskylae (Finland). Polttoaine- ja Polttotekniikan Lab.)

    1990-01-01

    In investigations in progress at the Fuel and Combustion Laboratory of the Technical Research Centre of Finland, we have been studying in co-operation with A. Ahlstrom Boiler Works, the removal of alkali metals from flue gases of ash-rich fuel with a dense suspension particle cooler. The applications of the particle cooler can be found in combined cycles and in industrial gas cleaning and heat recovery. We have also developed a general mathematical model of heat and mass transfer as well as chemical and physical reactions in multiphase systems.

  11. SOx-NOx-Rox Box{trademark} flue gas clean-up demonstration. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    The SNRB{trademark} Flue Gas Cleanup Demonstration Project was cooperatively funded by the U.S. Department of Energy (DOE), the Ohio Coal Development Office (OCDO), B&W, the Electric Power Research Institute (EPRI), Ohio Edison, Norton Chemical Process Products Company and the 3M Company. The SNRB{trademark} technology evolved from the bench and laboratory pilot scale to be successfully demonstrated at the 5-MWe field scale. Development of the SNRB{trademark} process at B&W began with pilot testing of high-temperature dry sorbent injection for SO{sub 2} removal in the 1960`s. Integration of NO{sub x} reduction was evaluated in the 1970`s. Pilot work in the 1980`s focused on evaluation of various NO{sub x} reduction catalysts, SO{sub 2} sorbents and integration of the catalyst with the baghouse. This early development work led to the issuance of two US process patents to B&W - No. 4,309,386 and No. 4,793,981. An additional patent application for improvements to the process is pending. The OCDO was instrumental in working with B&W to develop the process to the point where a larger scale demonstration of the technology was feasible. This report represents the completion of Milestone M14 as specified in the Work Plan. B&W tested the SNRB{trademark} pollution control system at a 5-MWe demonstration facility at Ohio Edison`s R. E. Burger Plant located near Shadyside, Ohio. The design and operation were influenced by the results from laboratory pilot testing at B&W`s Alliance Research Center. The intent was to demonstrate the commercial feasibility of the SNRB{trademark} process. The SNRB{trademark} facility treated a 30,000 ACFM flue gas slipstream from Boiler No. 8. Operation of the facility began in May 1992 and was completed in May 1993.

  12. Regenerable cobalt oxide loaded magnetosphere catalyst from fly ash for mercury removal in coal combustion flue gas.

    Science.gov (United States)

    Yang, Jianping; Zhao, Yongchun; Zhang, Junying; Zheng, Chuguang

    2014-12-16

    To remove Hg(0) in coal combustion flue gas and eliminate secondary mercury pollution of the spent catalyst, a new regenerable magnetic catalyst based on cobalt oxide loaded magnetospheres from fly ash (Co-MF) was developed. The catalyst, with an optimal loading of 5.8% cobalt species, attained approximately 95% Hg(0) removal efficiency at 150 °C under simulated flue gas atmosphere. O2 could enhance the Hg(0) removal activity of magnetospheres catalyst via the Mars-Maessen mechanism. SO2 displayed an inhibitive effect on Hg(0) removal capacity. NO with lower concentration could promote the Hg(0) removal efficiency. However, when increasing the NO concentration to 300 ppm, a slightly inhibitive effect of NO was observed. In the presence of 10 ppm of HCl, greater than 95.5% Hg(0) removal efficiency was attained, which was attributed to the formation of active chlorine species on the surface. H2O presented a seriously inhibitive effect on Hg(0) removal efficiency. Repeated oxidation-regeneration cycles demonstrated that the spent Co-MF catalyst could be regenerated effectively via thermally treated at 400 °C for 2 h.

  13. Positive dielectrophoresis used for selective trapping of nanoparticles from flue gas in a gradient field electrodes device

    Energy Technology Data Exchange (ETDEWEB)

    Lungu, Mihail, E-mail: lmihai@physics.uvt.ro; Neculae, Adrian; Lungu, Antoanetta [West University of Timisoara, Faculty of Physics (Romania)

    2015-12-15

    This paper investigates the possibility to use positive dielectrophoresis (pDEP) for selective trapping of nanoparticle dispersed in flue gas in a vertical pDEP-based microfluidic system. The experimental gradient field electrodes device contains as main part a vertical deposition plate with parallel planar electrodes in single connection on an insulating substrate, parallel to the reference electrode—a dielectric plate with a metalized side. The performances of the device were described and analyzed by numerical simulations and experimental tests in terms of two new specific parameters, called Retention rate and Filtration, related to the trapping of nanoparticles in suspension inside the device and the consequent purification of flue gas. It is outlined, both numerically and experimentally, that the concentration of particles trapped inside the device decreases as they are moving away from the inlet zone. The experimental results also highlight the nanoparticle size distribution of the particles collected from the deposition plate, using a nanoparticle tracking analysis method, and their selective capture on the deposition plate, depending on the amplitude and shape of the applied voltage, in a good agreement with the numerical simulations results.

  14. Investigation of the gypsum quality at three full-scale wet flue gas desulphurisation plants

    DEFF Research Database (Denmark)

    Hansen, Brian Brun; Kiil, Søren; Johnsson, Jan Erik

    2011-01-01

    In the present study the gypsum (CaSO4·2H2O) quality at three full-scale wet flue gas desulphurisation (FGD) plants and a pilot plant were examined and compared. Gypsum quality can be expressed in terms of moisture content (particle size and morphology dependent) and the concentration of residual......, low moisture content and low impurity content). An episode concerning a sudden deterioration in the gypsum dewatering properties was furthermore investigated, and a change in crystal morphology, as well as an increased impurity content (aluminium, iron and fluoride), was detected....

  15. Non-carbon sorbents for mercury removal from flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Alptekin, G.O.; Dubovik, M.; Cesario, M. [TDA Research Inc., Wheat Ridge, CO (United States)

    2005-07-01

    TDA Research Inc. is developing a new sorbent that can effectively remove mercury from flue gases. It is made of non-carbon based materials and will therefore not alter the properties of the fly ash. The sorbent can be produced as an injectable powder. The paper summarises the initial testing results of the new sorbent. The sorbent exhibited 7.5 to 11.0 mg/g mercury absorption capacity under representative flue gas streams depending on the operating temperature and gas hourly space velocity. The sorbent also showed resistance to sulfur poisoning by sulfur dioxide. 6 refs., 3 figs., 1 tab.

  16. On-line monitoring of trace compounds in the flue gas of an incineration pilot plant: Formation of polycyclic aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Heger, H. J.; Zimmermann, R.; Dorfner, R.; Kettrup, A.; Boesl, U.

    1998-01-01

    Laser mass spectrometry is applied for on-line analysis of PAHs from a complex flue gas matrix in the combustion chamber of an incineration plant. Process monitoring of industrial processes can be performed. New insights into the formation of toxic combustion byproducts are possible

  17. Near-Zero Emissions Oxy-Combustion Flue Gas Purification

    Energy Technology Data Exchange (ETDEWEB)

    Minish Shah; Nich Degenstein; Monica Zanfir; Rahul Solunke; Ravi Kumar; Jennifer Bugayong; Ken Burgers

    2012-06-30

    The objectives of this project were to carry out an experimental program to enable development and design of near zero emissions (NZE) CO{sub 2} processing unit (CPU) for oxy-combustion plants burning high and low sulfur coals and to perform commercial viability assessment. The NZE CPU was proposed to produce high purity CO{sub 2} from the oxycombustion flue gas, to achieve > 95% CO{sub 2} capture rate and to achieve near zero atmospheric emissions of criteria pollutants. Two SOx/NOx removal technologies were proposed depending on the SOx levels in the flue gas. The activated carbon process was proposed for power plants burning low sulfur coal and the sulfuric acid process was proposed for power plants burning high sulfur coal. For plants burning high sulfur coal, the sulfuric acid process would convert SOx and NOx in to commercial grade sulfuric and nitric acid by-products, thus reducing operating costs associated with SOx/NOx removal. For plants burning low sulfur coal, investment in separate FGD and SCR equipment for producing high purity CO{sub 2} would not be needed. To achieve high CO{sub 2} capture rates, a hybrid process that combines cold box and VPSA (vacuum pressure swing adsorption) was proposed. In the proposed hybrid process, up to 90% of CO{sub 2} in the cold box vent stream would be recovered by CO{sub 2} VPSA and then it would be recycled and mixed with the flue gas stream upstream of the compressor. The overall recovery from the process will be > 95%. The activated carbon process was able to achieve simultaneous SOx and NOx removal in a single step. The removal efficiencies were >99.9% for SOx and >98% for NOx, thus exceeding the performance targets of >99% and >95%, respectively. The process was also found to be suitable for power plants burning both low and high sulfur coals. Sulfuric acid process did not meet the performance expectations. Although it could achieve high SOx (>99%) and NOx (>90%) removal efficiencies, it could not produce by

  18. Determination of lead, zinc and benzo(a)pyrene in incineration flue gas

    International Nuclear Information System (INIS)

    Han Baohua; Gao Zhuqin; Guo Qian

    2003-01-01

    An analitical method was developed for the determination of lead(Pb), zinc(Zn) and benzo(a)pyrene (BaP) in flue gas of radwaste pyroysis incinerator, respectively using Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and High Performance Liquid Chromatography (HPLC). The sample preparation and the influence of major components in back-ground were researched. Interference correction coefficient for Pb and Zn are given in this article. The recovery of Pb, Zn and BaP are all above 84.0% and the relative standard deviation (RSD) were 3.51% for Pb, 7.28% for Zn and 4.50% for BaP, respectively. It shows that this analytical method can meet the incineration processes. (authors)

  19. Fouling reduction characteristics of a no-distributor-fluidized-bed heat exchanger for flue gas heat recovery

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Y.D.; Lee, K.B.; Islam, S.Z.; Ko, S.B. [Kongju National University, Kong Ju (Republic of Korea). Dept. for Mechanical Engineering

    2008-07-01

    In conventional flue gas heat recovery systems, the fouling by fly ashes and the related problems such as corrosion and cleaning are known to be major drawbacks. To overcome these problems, a single-riser no-distributor-fluidized-bed heat exchanger is devised and studied. Fouling and cleaning tests are performed for a uniquely designed fluidized bed-type heat exchanger to demonstrate the effect of particles on the fouling reduction and heat transfer enhancement. The tested heat exchanger model (1 m high and 54 mm internal diameter) is a gas-to-water type and composed of a main vertical tube and four auxiliary tubes through which particles circulate and transfer heat. Through the present study, the fouling on the heat transfer surface could successfully be simulated by controlling air-to-fuel ratios rather than introducing particles through an external feeder, which produced soft deposit layers with 1 to 1.5 mm thickness on the inside pipe wall. Flue gas temperature at the inlet of heat exchanger was maintained at 450{sup o}C at the gas volume rate of 0.738 to 0.768 CMM (0.0123 to 0.0128 m{sup 3}/sec). From the analyses of the measured data, heat transfer performances of the heat exchanger before and after fouling and with and without particles were evaluated. Results showed that soft deposits were easily removed by introducing glass bead particles, and also heat transfer performance increased two times by the particle circulation. In addition, it was found that this type of heat exchanger had high potential to recover heat of waste gases from furnaces, boilers, and incinerators effectively and to reduce fouling related problems.

  20. Highly integrated CO2 capture and conversion: Direct synthesis of cyclic carbonates from industrial flue gas

    KAUST Repository

    Barthel, Alexander; Saih, Youssef; Gimenez, Michel; Pelletier, Jeremie; Kü hn, Fritz Elmar; D´ Elia, Valerio; Basset, Jean-Marie

    2016-01-01

    Robust and selective catalytic systems based on early transition metal halides (Y, Sc, Zr) and organic nucleophiles were found able to quantitatively capture CO2 from diluted streams via formation of hemicarbonate species and to convert it to cyclic organic carbonates under ambient conditions. This observation was exploited in the direct and selective chemical fixation of flue gas CO2 collected from an industrial exhaust, affording high degrees of CO2 capture and conversion.

  1. Highly integrated CO2 capture and conversion: Direct synthesis of cyclic carbonates from industrial flue gas

    KAUST Repository

    Barthel, Alexander

    2016-02-08

    Robust and selective catalytic systems based on early transition metal halides (Y, Sc, Zr) and organic nucleophiles were found able to quantitatively capture CO2 from diluted streams via formation of hemicarbonate species and to convert it to cyclic organic carbonates under ambient conditions. This observation was exploited in the direct and selective chemical fixation of flue gas CO2 collected from an industrial exhaust, affording high degrees of CO2 capture and conversion.

  2. Methods for dry desulfurization of flue gas

    International Nuclear Information System (INIS)

    Bjondahl, F.

    2002-01-01

    In this report different types of dry desulfurization processes are de-scribed. These processes are utilized for the removal of SO 2 from flue gases. Basic process descriptions, information on different sorbent types and their properties and some comments based on the authors own experience are included. Information on disposal or use of the end product from these processes is also provided. (orig.)

  3. Overview of the EBFGT installation solutions applicable for flue gases from various fuels combustion

    International Nuclear Information System (INIS)

    Chmielewski, A.G.; Tyminski, B.; Pawelec, A.; Zimek, Z.; Licki, J.

    2011-01-01

    The overview of the solutions used in EBFGT process and adaptation of process parameters for flue gas from combustion of various fuels was presented. The inlets parameters of flue gas from four fuels with high emission of pollutants, process parameters and process constrain were analysed. Also the main problems of this technology and their solutions were presented. (author)

  4. Overview of the EBFGT installation solutions applicable for flue gases from various fuels combustion

    Energy Technology Data Exchange (ETDEWEB)

    Chmielewski, A. G.; Tyminski, B.; Pawelec, A.; Zimek, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland); Licki, J. [Institute of Atomic Energy, Otwock-Świerk (Poland)

    2011-07-01

    The overview of the solutions used in EBFGT process and adaptation of process parameters for flue gas from combustion of various fuels was presented. The inlets parameters of flue gas from four fuels with high emission of pollutants, process parameters and process constrain were analysed. Also the main problems of this technology and their solutions were presented. (author)

  5. Integrated hot fuel gas cleaning for advanced gasification combined cycle process

    Energy Technology Data Exchange (ETDEWEB)

    Nieminen, M.; Kangasmaa, K.; Laatikainen, J.; Staahlberg, P.; Kurkela, E. [VTT Energy, Espoo (Finland). Gasification and Advanced Combustion

    1996-12-01

    The fate of halogens in pressurised fluidized-bed gasification and hot gas filtration is determined. Potential halogen removal sorbents, suitable for integrated hot gas cleaning, are screened and some selected sorbents are tested in bench scale. Finally, halogen removal results are verified using the PDU-scale pressurised fluidized-bed gasification and integrated hot gas cleaning facilities of VTT. The project is part of the JOULE II Extension programme of the European Union. (author)

  6. Effect of gas release in hot molding on flexural strength of composite friction brake

    Science.gov (United States)

    Rusdja, Andy Permana; Surojo, Eko; Muhayat, Nurul; Raharjo, Wijang Wisnu

    2018-02-01

    Composite friction brake is a vital part of braking system which serves to reduce the speed of vehicle. To fulfill the requirement of brake performance, composite friction brake must have friction and mechanical characteristic as required. The characteristics of composite friction brake are affected by brake material formulation and manufacturing parameter. In the beginning of hot molding, intermittent hot pressing was carried out to release the gases that consist of ammonia gas and water vapor. In composite friction brake, phenolic resin containing hexamethylenetetramine (HMTA) is often used as a binder. During hot molding, the reaction of phenolic resin and HMTA forms ammonia gas. Hot molding also generates water vapor because raw materials absorb moisture from environment when they are placed in storage. The gas release in hot molding is supposed affecting mechanical properties because it avoid entrapped gas in composite, so that this research investigated effect of gas release on flexural strength. Manufacturing of composite specimen was carried out as follow: mixing of raw materials, cold molding, and hot molding. In this research, duration of intermittent hot pressing and number of gas release were varied. The flexural strength of specimen was measured using three point bending test. The results showed that flexural strength specimens that were manufactured without gas release, using 4 times gas release with intermittent hot pressing for 5 and 10 seconds were not remarkably different. Conversely, hot molding using 4 times gas release with intermittent hot pressing for 15 seconds decreased flexural strength of composite. Hot molding using 2, 4, and 8 times gas release with intermittent hot pressing for 10 seconds also had no effect on increasing flexural strength. Increasing of flexural strength of composite was obtained only by using 6 times gas release with intermittent hot pressing for 10 seconds.

  7. Avoiding Carbon Bed Hot Spots in Thermal Process Off-Gas Systems

    International Nuclear Information System (INIS)

    Soelberg, Nick; Enneking, Joe

    2011-01-01

    Mercury has had various uses in nuclear fuel reprocessing and other nuclear processes, and so is often present in radioactive and mixed (radioactive and hazardous) wastes. Test programs performed in recent years have shown that mercury in off-gas streams from processes that treat radioactive wastes can be controlled using fixed beds of activated sulfur-impregnated carbon, to levels low enough to comply with air emission regulations such as the Hazardous Waste Combustor (HWC) Maximum Achievable Control Technology (MACT) standards. Carbon bed hot spots or fires have occurred several times during these tests, and also during a remediation of tanks that contained mixed waste. Hot spots occur when localized areas in a carbon bed become heated to temperatures where oxidation occurs. This heating typically occurs due to heat of absorption of gas species onto the carbon, but it can also be caused through external means such as external heaters used to heat the carbon bed vessel. Hot spots, if not promptly mitigated, can grow into bed fires. Carbon bed hot spots and fires must be avoided in processes that treat radioactive and mixed waste. Hot spots are detected by (a) monitoring in-bed and bed outlet gas temperatures, and (b) more important, monitoring of bed outlet gas CO concentrations. Hot spots are mitigated by (a) designing for appropriate in-bed gas velocity, for avoiding gas flow maldistribution, and for sufficient but not excessive bed depth, (b) appropriate monitoring and control of gas and bed temperatures and compositions, and (c) prompt implementation of corrective actions if bed hot spots are detected. Corrective actions must be implemented quickly if bed hot spots are detected, using a graded approach and sequence starting with corrective actions that are simple, quick, cause the least impact to the process, and are easiest to recover from.

  8. Producing ammonium sulfate from flue gas desulfurization by-products

    Science.gov (United States)

    Chou, I.-Ming; Bruinius, J.A.; Benig, V.; Chou, S.-F.J.; Carty, R.H.

    2005-01-01

    Emission control technologies using flue gas desulfurization (FGD) have been widely adopted by utilities burning high-sulfur fuels. However, these technologies require additional equipment, greater operating expenses, and increased costs for landfill disposal of the solid by-products produced. The financial burdens would be reduced if successful high-volume commercial applications of the FGD solid by-products were developed. In this study, the technical feasibility of producing ammonium sulfate from FGD residues by allowing it to react with ammonium carbonate in an aqueous solution was preliminarily assessed. Reaction temperatures of 60, 70, and 80??C and residence times of 4 and 6 hours were tested to determine the optimal conversion condition and final product evaluations. High yields (up to 83%) of ammonium sulfate with up to 99% purity were achieved under relatively mild conditions. The optimal conversion condition was observed at 60??C and a 4-hour residence time. The results of this study indicate the technical feasibility of producing ammonium sulfate fertilizer from an FGD by-product. Copyright ?? Taylor & Francis Inc.

  9. Recovery of flue gas energy in heat integrated IGCC power plants using the contact economizer system

    CSIR Research Space (South Africa)

    Madzivhandila, V

    2010-10-01

    Full Text Available Asia Pacific Confederation of APCChE 2010 Chemical Engineering Congress October 5-8, 2010, Taipei � �� Recovery of flue gas energy in heat integrated IGCC power plants using the contact economizer system Vhutshilo Madzivhandilaa, Thokozani... temperature and the thermal efficiency of the plant. The 13th Asia Pacific Confederation of APCChE 2010 Chemical Engineering Congress October 5-8, 2010, Taipei � �� 1. Introduction The IGCC (Integrated Gasification Combined Cycle) is one...

  10. Manufacture and qualification of hot roll-clad composites with nickel base cladding material for use in flue gas desulphurization plants. Final report; Herstellung und Qualifizierung warmwalzplattierter Verbundwerkstoffe mit Nickelbasisauflagen fuer den Einsatz in Rauchgasentschwefelungsanlagen. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Kirchheiner, R.; Stenner, F.

    1992-03-16

    Flue gas desulphurization plants (FGD), which have been required by law since 1983, mainly apply wet scrubbing techniques. The chemical reactions taking place in those plants lead to extremely corrosive situations. Unprotected carbon steel surfaces or organic based anticorrosive systems are extremely affected after being in operation for only a few years. NiCrM alloys applied by the chemical industry in comparable situations have proved their efficiency for decades. When such massive components are newly built in FDGs, economic aspects require the use of those NiCrMo alloys in clad form. Within the frame of this project tests included the manufacture of hot roll-clad composites comprising cladding materials of the type NiMo16Cr15W (2.4819) and NiCr21Mo14W (2.4602) on the base steel RST 37-2. Large-sized sheets (10000 x 2000 x 10+2 mm) were made by means of an optimized cladding technique. The behaviour of the cladding material in case of uniform and local corrosion exposure was examined in standard laboratory tests. An increased susceptibility to intercrystalline corrosion was not detected, according to the excellent microstructure. Further laboratory tests under simulated FGD conditions and exposure tests in FGDs in operation permitted the transfer of those positive test results to practical work. The same applies without limitation to the joint-welded state with similar filler material of clad a comparable chemical composition. With respect to their technological behaviour the new hot roll-clad composites correspond to that of solid sheets of NiCrMo alloys; therefore they are qualified for use in flue gas desulphurization plants. (orig./BBR) With 32 refs., 13 tabs., 29 figs. [Deutsch] In den seit 1983 gesetzlich vorgeschriebenen Anlagen zur Rauchgasentschwefelung (REA) werden ueberwiegend nasse Waschverfahren eingesetzt. Die in diesen Anlagen ablaufenden chemischen Reaktionen fuehren zu extrem korrosiven Bedingungen. Ungeschuetzte C-Stahl-Oberflaechen bzw

  11. A breakthrough in flue gas cleanup, CO2 mitigation and H2S removal

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Wolf; Wasas, James; Stenger, Raymond; Howell, Evan

    2010-09-15

    SWAPSOL Corp. is developing commercial processes around a newly discovered reaction that reduces H2S below detectable levels while reacting with CO2 to form water, sulfur and carsuls, a carbon-sulfur polymer. The Stenger-Wasas Process (SWAP) stands to simplify sulfur removal technology as it consumes CO2 in an exothermic reaction. The SWAP has applications in landfill, sour, flue and Claus tail gas cleanup and may replace Claus technology. Destruction of waste hydrocarbons provides a source of H2S. The primary reactions and variants have been independently verified and the chemical kinetics determined by a third party laboratory.

  12. Using 13X, LiX, and LiPdAgX zeolites for CO_2 capture from post-combustion flue gas

    International Nuclear Information System (INIS)

    Chen, S.J.; Zhu, M.; Fu, Y.; Huang, Y.X.; Tao, Z.C.; Li, W.L.

    2017-01-01

    Highlights: • We synthesized a novel adsorbent named LiPdAgX zeolite. • CCS was proposed from microstructure, selectivity and separation factor of zeolite. • The static and flowing adsorption using CO_2/N_2 mixture on X zeolites were studied. • LiPdAgX zeolite required less energy for regeneration compared to 13X and MEA. • LiPdAgX zeolite can effectively capture CO_2 from post-combustion flue gas. - Abstract: This work investigates the application of X zeolites for capturing CO_2 from post-combustion flue gas. LiX and LiPdAgX zeolites were prepared by an ion-exchange method using 13X zeolite. X-ray diffraction analysis showed that all samples exhibited characteristic peaks of X zeolites, where the peak intensities increased in the order: LiPdAgX > LiX > 13X. The enhanced intensity of the diffraction peaks can increase the activity of the X zeolites and improve their adsorption performance. Scanning electron microscopy imaging showed that the intergranular pore canals of LiPdAgX zeolite were more concentrated. Pore structure analysis indicated that addition of Li"+ to the 13X zeolite enhanced the specific surface areas and pore volumes of the zeolites. Among the 13X, LiX, and LiPdAgX zeolites, LiPdAgX showed the highest CO_2/N_2selectivity, where the difference in the CO_2 adsorption capacity was due to differences in the number of adsorption sites and thermal conductivities of the X zeolites. The CO_2 breakthrough time increased in succession for the 13X, LiX, and LiPdAgX zeolites. The CO_2/N_2 separation factor of the LiPdAgX zeolite was twice that of the 13X zeolite at a CO_2 concentration of 20 vol.%. The temperature variations during the adsorption process were used to determine the regeneration energy and adsorption capacity of the X zeolites. LiPdAgX zeolite required less energy for regeneration than 13X zeolite and MEA. After regeneration, the separation factor of LiPdAgX zeolite remained at 6.38 for 20 vol.% CO_2 in the flue gas. Therefore, Li

  13. Two-branch Gas Experiments for Hot Gas Mixing of HTR-PM

    International Nuclear Information System (INIS)

    Zhou Yangping; Hao Pengefei; He Heng; Li Fu; Shi Lei

    2014-01-01

    A model experiment is proposed to investigate the hot gas mixing efficiency of HTR-PM reactor outlet. The test facility is introduced which is set at a scale of 1:2.5 comparing with the design of thermal mixing structure at HTR-PM reactor outlet. The test facility using air as its flow media includes inlet pipe system, electric heaters, main body of test facility, hot gas duct, exhaust pipe system and I&C system. Two-branch gas experiments are conducted on the test facility and the values of thermal-fluid parameters are collected and analyzed which include the temperature, pressure and velocity of the flow as well as the temperature of the tube wall. The analysis result shows the mixing efficiency is higher than the requirement of thermal mixing by steam generator even with conservative assumption which indicates that the design of hog gas mixing structure of HTR-PM fulfills the requirement for thermal mixing at two-branch working conditions. (author)

  14. An electron beam flue gas treatment plant for a coal fired thermal power station. EBA demonstration plant in Chengdu thermal power station (China EBA Project)

    International Nuclear Information System (INIS)

    Doi, Yoshitaka; Nakanishi, Ikuo; Shi, Jingke

    1999-01-01

    Ebara's electron beam flue gas treatment plant was installed and is being demonstrated in Chengdu Thermal Power Station, Sichuan, China. The demonstration is proving that this plant is fully capable of meeting the target removal of sulfur dioxides from flue gas (flow rate : 300-thousand m 3 /h). Recovered by-products, namely ammonium sulfate and ammonium nitrate, from the treatment were actually tested as fertilizers, the result of which was favorable. The sale and distribution of these by-products are already underway. In May 1995, this plant was presented the certificate of authorization by China's State Power Corporation. It is noted that this was the first time a sulfur dioxide removal plant was certified as such in China. (author)

  15. CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS

    International Nuclear Information System (INIS)

    David A. Green; Brian S. Turk; Raghubir P. Gupta; Alejandro Lopez-Ortiz; Douglas P. Harrison; Ya Liang

    2001-01-01

    Electrobalance studies of calcination and carbonation of sodium bicarbonate materials were conducted at Louisiana State University. Calcination in an inert atmosphere was rapid and complete at 120 C. Carbonation was temperature dependent, and both the initial rate and the extent of reaction were found to decrease as temperature was increased between 60 and 80 C. A fluidization test apparatus was constructed at RTI and two sodium bicarbonate materials were fluidized in dry nitrogen at 22 C. The bed was completely fluidized at between 9 and 11 in. of water pressure drop. Kinetic rate expression derivations and thermodynamic calculations were conducted at RTI. Based on literature data, a simple reaction rate expression, which is zero order in carbon dioxide and water, was found to provide the best fit against reciprocal temperature. Simulations based on process thermodynamics suggested that approximately 26 percent of the carbon dioxide in flue gas could be recovered using waste heat available at 240 C

  16. CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS

    Energy Technology Data Exchange (ETDEWEB)

    David A. Green; Brian S. Turk; Raghubir P. Gupta; Alejandro Lopez-Ortiz; Douglas P. Harrison; Ya Liang

    2001-05-01

    Electrobalance studies of calcination and carbonation of sodium bicarbonate materials were conducted at Louisiana State University. Calcination in an inert atmosphere was rapid and complete at 120 C. Carbonation was temperature dependent, and both the initial rate and the extent of reaction were found to decrease as temperature was increased between 60 and 80 C. A fluidization test apparatus was constructed at RTI and two sodium bicarbonate materials were fluidized in dry nitrogen at 22 C. The bed was completely fluidized at between 9 and 11 in. of water pressure drop. Kinetic rate expression derivations and thermodynamic calculations were conducted at RTI. Based on literature data, a simple reaction rate expression, which is zero order in carbon dioxide and water, was found to provide the best fit against reciprocal temperature. Simulations based on process thermodynamics suggested that approximately 26 percent of the carbon dioxide in flue gas could be recovered using waste heat available at 240 C.

  17. Addressing the Impact of Environmental Xenobiotics in Coal-Fired Flue Gas

    Directory of Open Access Journals (Sweden)

    Cornelia A. Bulucea

    2015-03-01

    Full Text Available Dangerous and unstable situations can result from the presence of environmental xenobiotics since their harmful effects on humans and ecosystems are often unpredictable, and building awareness of the environmental risk should be a main concern of humankind. The environmental xenobiotics in the flue gas from a fossil fuel-fired electrical generating station, such as particulate matter (PM, sulfur dioxide (SO2, nitrogen oxides (NOx, and carbon dioxide (CO2, are analyzed in this study, since these xenobiotics are persistent pollutants. Mathematical models of the environmental pollutant vector, estimating the emission factors specific to fossil fuel combustion, are applied to the operation of thermal units in the Turceni electrical generating station, each of which produces a net electrical power of 330 MW. For each stack gas component in the pollutant vector, emission factors and pollutant concentrations are determined. A pattern is also examined depicting the mathematically modelled processes of resonant absorption of an environmental xenobiotic harmonic oscillation by an organism modulated as an absorbing oscillator structure. The xenobiotic concentration degree is represented through a spatial concentration vector, which allows further modelling and simulation of the oscillating regime of environmental xenobiotic absorption.

  18. Simultaneous removal of SO2, NO and Hg0 from flue gas by ferrate (VI) solution

    International Nuclear Information System (INIS)

    Zhao, Yi; Han, Yinghui; Guo, Tianxiang; Ma, Tianzhong

    2014-01-01

    Simultaneously removing SO 2 , NO and Hg 0 from flue gas was examined by ferrate (VI) solution at a bubbling reactor. The removal efficiencies of 100% for SO 2 , 64.8% for NO and 81.4% for Hg 0 were achieved respectively, under the optimum experimental conditions, in which concentration of ferrate (VI) solution was 0.25 mmol/L, solution pH was 8.0, flue gas flow rate was 1 L/min and reaction temperature was 320 K. Based on the discussions of the ferrate (VI) solution characteristics, the comparisons of the standard electrode potential (E 0 ) of ferrate (VI) solution with E 0 values of reactant, and the analysis of the reaction products, a mechanism of simultaneous removal was proposed. In the process of simultaneous removal, FeO 4 2− and HFeO 4 − as the dominant species of ferrate (VI), could rapidly oxidize SO 2 , NO, and Hg 0 into SO 4 2− , NO 3 − and Hg 2+ . - Highlights: • Prepared ferrate (VI) absorbent has excellent property of removing SO 2 , NO and Hg 0 . • 100% of SO 2 , 63.8% of NO and 83.6% of Hg 0 were simultaneously removed. • The simultaneous removal mechanism of SO 2 , NO and Hg 0 was proposed

  19. Study on the associated removal of pollutants from coal-firing flue gas using biomass activated carbon pellets

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Cuiping; Yuan, Wanli [Qingdao Univ., Shandong (China). Electrical and Mechanical Engineering College; Qi, Haiying [Tsinghua Univ., Beijing (China). Dept. of Thermal Engineering

    2013-07-01

    A pilot-scale multi-layer system was developed for the adsorption of SO{sub 2}/NO{sub x}/Hg from flue gas (real flue gases of an heating boiler house) at various operating conditions, including operating temperature and activated carbon materials. Excellent SO{sub 2}/NO{sub x}/Hg removal efficiency was achieved with the multi-layer design with carbons pellets. The SO{sub 2} removal efficiency achieved with the first layer adsorption bed clearly decreased as the operating temperature was increased due to the decrease of physisorption performance. The NO{sub x} removal efficiency measured at the second layer adsorption bed was very higher when the particle carbon impregnated with NH{sub 3}. The higher amounts of Hg absorbed by cotton-seed-skin activated carbon (CSAC) were mainly contributed by chlorinated congeners content. The simultaneously removal of SO{sub 2}/NO{sub x}/Hg was optimization characterized with different carbon layer functions. Overall, The alkali function group and chloride content in CSAC impelled not only the outstanding physisorption but also better chemisorptions. The system for simultaneously removal of multi-pollutant-gas with biomass activated carbon pellets in multi-layer reactor was achieved and the removal results indicated was strongly depended on the activated carbon material and operating temperature.

  20. Irradiation induced aerosol formation in flue gas: experiments on low doses

    International Nuclear Information System (INIS)

    Maekelae, J.M.

    1992-01-01

    Laboratory experiments on irradiation induced aerosol formation from gaseous sulphur dioxide in humid air are presented. This work is connected to the aerosol particle formation process in the electron beam technique for cleaning flue gas. As a partial process of this method primary products of the radiolysis of water vapour convert sulphur dioxide into gaseous sulphuric acid which then nucleates with water vapour forming small acid droplets. This experimental work has been performed on relatively low absorbed doses. Aerosol particle formation is strongly dependent on dose. In the experiments, the first aerosol particles were detected already on absorbed doses of 0.1-10 mGy. The particle size in these cases is in the so-called ultrafine size range (1-20 nm). In this article three experimental set-ups with some characteristic results are presented. (Author)

  1. Desulfurization of chemical waste gases and flue gases with economic utilization of air pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, K.; Wischnewski, W.

    1983-09-01

    The technological state of recovery of sulfur dioxide from waste and flue gases in the GDR is discussed. Two examples of plants are presented: a pyrosulfuric acid plant in Coswig, recovering sulfur dioxide from gases by absorption with sodium hydroxide, followed by catalytic oxidation to sulfur trioxide, and a plant for waste sulfuric acid recovery from paraffin refining, where the diluted waste acid is sprayed into a furnace and recovered by an ammonium-sulfite-bisulfite solution from the combustion gas (with 4 to 10% sulfur dioxide content). Investment and operation costs as well as profits of both plants are given. Methods employed for power plant flue gas desulfurization in major industrial countries are further assessed: about 90% of these methods uses wet flue gas scrubbing with lime. In the USA flue gas from 25,000 MW of power plant capacity is desulfurized. In the USSR, a 35,000 m/sup 3//h trial plant at Severo-Donetzk is operating using lime, alkali and magnesite. At the 150 MW Dorogobush power plant in the USSR a desulfurization plant using a cyclic ammonia process is under construction.

  2. Ecological comparison between hydrated lime and sodium bicarbonate when used for dry flue gas purification; Oekologischer Vergleich von Kalkhydrat und Natriumbicarbonat beim Einsatz in der trockenen Rauchgasreinigung

    Energy Technology Data Exchange (ETDEWEB)

    Wecker, Andreas [Federal German Association of the Lime Industry, Koeln (Germany)

    2009-07-01

    Lime plays an important role in environmental protection. Not only due to its properties but also due to its natural occurrence, it is suitable and accepted for universal application in the environment sector. Lime and its refined products can be used in various processes to remove the acid gases, the gaseous metal compounds and organic trace constituents from the flue gas of waste incineration plants. The choice of the suitable process depends on the raw gas load, the separation efficiency to be achieved and the way of recovery of the reaction product obtained as a result of flue gas cleaning. The dry sorption processes have been established for many years and have been continuously further developed, in which lime is injected into the flue gas flow and the reaction product is retained via a filtering separator. As an alternative to lime products, it is also possible, under certain boundary conditions, to use sodium hydrogen-carbonate NaHCO{sub 3} (below called sodium bicarbonate) as a basic reaction component in the dry sorption process. As opposed to calcium hydroxide, there are differences, for example as regards the reaction temperature required and the necessary amount of sorbent to achieve the desired purification effect. (orig.)

  3. Increasing the efficiency of heating systems by reducing the flue gas temperature below the dew point

    Energy Technology Data Exchange (ETDEWEB)

    Kremer, H.

    1981-06-01

    This paper deals with the fundamentals and technical possibilities of increasing the combustion efficiency of gas-fired heating units for domestic heating by cooling the flue gases below their water vapor saturation temperature. The improvement of the efficiency can be more than 15% in comparison even to modern warm water heating boilers. Important however is the availability of cooling fluids of sufficiently low temperatures which could be recirculated heating water, freshwater and air. Different possible applications of this method are discussed in detail.

  4. Advanced air/flue gas staging based on CFD modelling for enhanced combustion and burnout in a waste-wood fired boiler

    DEFF Research Database (Denmark)

    Rajh, Boštjan; Yin, Chungen; Samec, Niko

    2017-01-01

    The paper presents the impacts of the jet momentum, position and orientation of air and Recycled Flue Gas (RFG) streams on the performance of a grate-fired boiler burning waste wood via a comprehensive CFD-based parametric study. It is found that the air and RFG jets can be optimized to enhance m...

  5. Advanced sulfur control concepts for hot gas desulfurization technology

    International Nuclear Information System (INIS)

    1998-01-01

    The objective of this project is to develop a hot-gas desulfurization process scheme for control of H 2 S in HTHP coal gas that can be more simply and economically integrated with known regenerable sorbents in DOE/METC-sponsored work than current leading hot-gas desulfurization technologies. In addition to being more economical, the process scheme to be developed must yield an elemental sulfur byproduct. The Direct Sulfur Recovery Process (DSRP), a leading process for producing an elemental sulfur byproduct in hot-gas desulfurization systems, incurs a coal gas use penalty, because coal gas is required to reduce the SO 2 in regeneration off-gas to elemental sulfur. Alternative regeneration schemes, which avoid coal gas use and produce elemental sulfur, will be evaluated. These include (i) regeneration of sulfided sorbent using SO 2 ; (ii) partial oxidation of sulfided sorbent in an O 2 starved environment; and (iii) regeneration of sulfided sorbent using steam to produce H 2 S followed by direct oxidation of H 2 S to elemental sulfur. Known regenerable sorbents will be modified to improve the feasibility of the above alternative regeneration approaches. Performance characteristics of the modified sorbents and processes will be obtained through lab- and bench-scale testing. Technical and economic evaluation of the most promising processes concept(s) will be carried out

  6. Physics of dust grains in hot gas

    International Nuclear Information System (INIS)

    Draine, B.T.; Salpeter, E.E.

    1979-01-01

    Charging of dust grains in hot (10 4 --10 9 K) plasma is studied, including photoelectron and secondary electron emission, field emission, and transmission of electrons and ions through the grain; resulting grain potentials are (for T > or approx. = 10 5 K) considerably smaller in magnitude than found by Burke and Silk. Even so, large electrostatic stresses can cause ion field emission and rapid destruction of small grains in very hot gas. Rapid rotation can also disrupt small grains, but damping (by microwave emission) usually limits the centrifugal stress to acceptable values for plasma densities n/sub H/ -3 . Sputtering rates are estimated for grains in hot gas, based upon a semiempirical fit to experimental data. Predicted sputtering rates for possible grain constituents are similar to estimates by Barlow, but in some cases differ significantly. Useful approximation formulae are given for the drag forces acting on a grain with arbitrary Mach number

  7. A hot air driven thermoacoustic-Stirling engine

    Energy Technology Data Exchange (ETDEWEB)

    Tijani, M.E.H.; Spoelstra, S. [ECN Biomass and Energy Efficiency, Petten (Netherlands)

    2012-09-15

    Significant energy savings can be obtained by implementing a thermally driven heat pump into industrial or domestic applications. Such a thermally driven heat pump uses heat from a high-temperature source to drive the system which upgrades an abundantly available heat source (industrial waste heat, air, water, geothermal). A way to do this is by coupling a thermoacoustic engine with a thermoacoustic heat pump. The engine is driven by a burner and produces acoustic power and heat at the required temperature. The acoustic power is used to pump heat in the heat pump to the required temperature. This system is attractive since it uses a noble gas as working medium and has no moving mechanical parts. This paper deals with the first part of this system: the engine. In this study, hot air is used to simulate the flue gases originating from a gas burner. This is in contrast with a lot of other studies of thermoacoustic engines that use an electrical heater as heat source. Using hot air resembles to a larger extent the real world application. The engine produces about 300W of acoustic power with a performance of 41% of the Carnot efficiency at a hot air temperature of 620C.

  8. A Diaminopropane-Appended Metal-Organic Framework Enabling Efficient CO2 Capture from Coal Flue Gas via a Mixed Adsorption Mechanism.

    Science.gov (United States)

    Milner, Phillip J; Siegelman, Rebecca L; Forse, Alexander C; Gonzalez, Miguel I; Runčevski, Tomče; Martell, Jeffrey D; Reimer, Jeffrey A; Long, Jeffrey R

    2017-09-27

    A new diamine-functionalized metal-organic framework comprised of 2,2-dimethyl-1,3-diaminopropane (dmpn) appended to the Mg 2+ sites lining the channels of Mg 2 (dobpdc) (dobpdc 4- = 4,4'-dioxidobiphenyl-3,3'-dicarboxylate) is characterized for the removal of CO 2 from the flue gas emissions of coal-fired power plants. Unique to members of this promising class of adsorbents, dmpn-Mg 2 (dobpdc) displays facile step-shaped adsorption of CO 2 from coal flue gas at 40 °C and near complete CO 2 desorption upon heating to 100 °C, enabling a high CO 2 working capacity (2.42 mmol/g, 9.1 wt %) with a modest 60 °C temperature swing. Evaluation of the thermodynamic parameters of adsorption for dmpn-Mg 2 (dobpdc) suggests that the narrow temperature swing of its CO 2 adsorption steps is due to the high magnitude of its differential enthalpy of adsorption (Δh ads = -73 ± 1 kJ/mol), with a larger than expected entropic penalty for CO 2 adsorption (Δs ads = -204 ± 4 J/mol·K) positioning the step in the optimal range for carbon capture from coal flue gas. In addition, thermogravimetric analysis and breakthrough experiments indicate that, in contrast to many adsorbents, dmpn-Mg 2 (dobpdc) captures CO 2 effectively in the presence of water and can be subjected to 1000 humid adsorption/desorption cycles with minimal degradation. Solid-state 13 C NMR spectra and single-crystal X-ray diffraction structures of the Zn analogue reveal that this material adsorbs CO 2 via formation of both ammonium carbamates and carbamic acid pairs, the latter of which are crystallographically verified for the first time in a porous material. Taken together, these properties render dmpn-Mg 2 (dobpdc) one of the most promising adsorbents for carbon capture applications.

  9. BENCH-SCALE DEMONSTRATION OF HOT-GAS DESULFURIZATION TECHNOLOGY

    International Nuclear Information System (INIS)

    Unknown

    2000-01-01

    The U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL), is sponsoring research in advanced methods for controlling contaminants in hot coal gasifier gas (coal-derived fuel-gas) streams of integrated gasification combined-cycle (IGCC) power systems. The hot gas cleanup work seeks to eliminate the need for expensive heat recovery equipment, reduce efficiency losses due to quenching, and minimize wastewater treatment costs. Hot-gas desulfurization research has focused on regenerable mixed-metal oxide sorbents that can reduce the sulfur in coal-derived fuel-gas to less than 20 ppmv and can be regenerated in a cyclic manner with air for multicycle operation. Zinc titanate (Zn(sub 2)TiO(sub 4) or ZnTiO(sub 3)), formed by a solid-state reaction of zinc oxide (ZnO) and titanium dioxide (TiO(sub 2)), is currently one of the leading sorbents. Overall chemical reactions with Zn(sub 2)TiO(sub 4) during the desulfurization (sulfidation)-regeneration cycle are shown. The sulfidation/regeneration cycle can be carried out in a fixed-bed, moving-bed, or fluidized-bed reactor configuration. The fluidized-bed reactor configuration is most attractive because of several potential advantages including faster kinetics and the ability to handle the highly exothermic regeneration to produce a regeneration offgas containing a constant concentration of SO(sub 2)

  10. BENCH-SCALE DEMONSTRATION OF HOT-GAS DESULFURIZATION TECHNOLOGY

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    The U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL), is sponsoring research in advanced methods for controlling contaminants in hot coal gasifier gas (coal-derived fuel-gas) streams of integrated gasification combined-cycle (IGCC) power systems. The hot gas cleanup work seeks to eliminate the need for expensive heat recovery equipment, reduce efficiency losses due to quenching, and minimize wastewater treatment costs. Hot-gas desulfurization research has focused on regenerable mixed-metal oxide sorbents that can reduce the sulfur in coal-derived fuel-gas to less than 20 ppmv and can be regenerated in a cyclic manner with air for multicycle operation. Zinc titanate (Zn(sub 2)TiO(sub 4) or ZnTiO(sub 3)), formed by a solid-state reaction of zinc oxide (ZnO) and titanium dioxide (TiO(sub 2)), is currently one of the leading sorbents. Overall chemical reactions with Zn(sub 2)TiO(sub 4) during the desulfurization (sulfidation)-regeneration cycle are shown. The sulfidation/regeneration cycle can be carried out in a fixed-bed, moving-bed, or fluidized-bed reactor configuration. The fluidized-bed reactor configuration is most attractive because of several potential advantages including faster kinetics and the ability to handle the highly exothermic regeneration to produce a regeneration offgas containing a constant concentration of SO(sub 2)

  11. Mechanical design and testing of a hot-gas turbine on a test facility

    International Nuclear Information System (INIS)

    Staude, R.

    1981-01-01

    Advanced calculation methods and specific solutions for any particular problem are basic requirements for the mechanical design of hot-gas components for gas turbines. The mechanical design contributes a great deal to the smooth running and operational reliability and thus to the quality of the machine. By reference to an expander, the present paper discusses the strength of hot components, such as the casing and the rotor, for both stationary and transient temperature distribution. Mechanical testing under hot-gas conditions fully confirmed the reliability of the rating and design of the hot-gas turbines supplied by M:A.N.-GHH STERKRADE. (orig.) [de

  12. Flue gas heat recovery operating below the dew point and its utilisation for low temperature heating installations

    Energy Technology Data Exchange (ETDEWEB)

    Wilsdorf, J.

    1986-11-01

    This paper deals at first with the characteristics of two principal systems for the flue gas heat recovery by reducing the temperature below the dew point. With test results on experimental plants are shown the typical differences between surface and direct contact heat exchange. A second part informs about experiences from the application for low temperature heating installations, especially about thermodynamics condensate quality and technical design. The possible increasing of the efficiency ranges between 10 to 20 per cent.

  13. Microbial reduction of SO{sub 2} and NO{sub x} as a means of by- product recovery/disposal from regenerable processes for the desulfurization of flue gas. Technical progress report, June 11, 1992--September 11, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Sublette, K.L.

    1992-12-31

    Based on the work described simultaneous SO{sub 2}/No{sub x} removal from flue gas based on direct contact of the gas with SRB and T. denitrificans co-cultures or cultures-in-series has been eliminated as a viable process concept at this time. The technical reasons are as follows: (1) NO inhibition of SO{sub 2} reduction by D. desulfuricans - Although the NO concentrations used in the experiments described above are somewhat higher than that found in a typical flue gas, it is quite possible that at lower NO concentrations (or partial pressures) the inhibiting effects will simply take longer to become apparent. (2) Nitrate suppression of NO removal - As noted previously, the cultivation of T. denitrificans in a microbial flue gas treatment system (either one or two stages) would require sulfide-limiting conditions. Therefore, the electron acceptor must be in excess, requiring nitrate in the T. denitrificans process culture. As shown in experiments described above, nitrate significantly suppresses the removal of NO from a feed gas making simultaneous SO{sub 2}/NO{sub x} removal impractical by microbial means. (3) O{sub 2} inhibition of SO{sub 2} and NO reduction - It has been demonstrated that D. desulfuricans working cultures are tolerant of up to 1.7% O{sub 2} in the feed gas. However, further increases in the O{sub 2} partial pressure in the feed gas resulted in O{sub 2} inhibition of SO{sub 2} reduction. These inhibiting levels of O{sub 2} are comparable to those concentrations found in flue gases (3). Therefore, in any process in which raw flue gas contacts a D. desulfuricans culture marginal stability at best can be expected.

  14. Separation of Flue-Gas Scrubber Sludge into Marketable Products

    International Nuclear Information System (INIS)

    1998-01-01

    The reduction of sulfur oxides from high sulfur coal burning utility companies has resulted in the production of huge quantities of wet flue-gas desulfurization scrubber sludge. A typical 400 MW power station burning a coal containing 3.5% sulfur by weight and using a limestone absorbent would produce approximately 177,000 tons (dry weight) of scrubber sludge per year. This brownish colored, finely divided material contains calcium sulfite (CaSO 3 · 1/2 H 2 O), calcium sulfate (CaSO 4 · 2H 2 O), unreacted limestone (CaCO 3 ), and various other impurities such as fly-ash and iron oxide particles. The physical separation of the components of scrubber sludge would result in the re-use of this material. The primary use would be conversion to a highly pure synthetic gypsum. This technical report concentrates on the effect of baffle configuration on the separation of calcium sulfite/sulfate from limestone. The position of the baffles as they related to the feed inlet, and the quantity of the baffles were examined. A clean calcium sulfite/sulfate (less than 2.0% limestone by weight) was achieved with the combination of water-only cyclone and horizontally baffled column

  15. Thermal performance test of hot gas ducts of helium engineering demonstration loop (HENDEL)

    International Nuclear Information System (INIS)

    Hishida, Makoto; Kunitomi, Kazuhiko; Ioka, Ikuo; Umenishi, Koji; Kondo, Yasuo; Tanaka, Toshiyuki; Shimomura, Hiroaki

    1984-01-01

    A hot gas duct provided with internal thermal insulation is supposed to be used for an experimental very high-temperature gas-cooled reactor (VHTR) which has been developed by the Japan Atomic Energy Research Institute (JAERI). This type of hot gas duct has not been used so far in industrial facilities, and only a couple of tests on such a large-scale model of hot gas duct have been conducted. The present test was to investigate the thermal performance of the hot gas ducts which are installed as parts of a helium engineering demonstration loop (HENDEL) of JAERI. Uniform temperature and heat flux distributions at the surface of the duct were observed, the experimental correlation being obtained for the effective thermal conductivity of the internal thermal insulation layer. The measured temperature distribution of the pressure tube was in good agreement with the calculation by a TRUMP heat transfer computer code. The temperature distribution of the inner tube of VHTR hot gas duct was evaluated, and no hot spot was detected. These results would be very valuable for the design and development of VHTR. (author)

  16. NOx and PAHs removal from industrial flue gas by using electron beam technology in the alcohol addition

    International Nuclear Information System (INIS)

    Sun, Y.X.; Chmielewski, A.G.; Bulka, S.; Zimek, Z.; Licki, J.; Kubica, K.

    2002-01-01

    Complete text of publication follows. The preliminary test of NO x and Polycyclic Aromatic Hydrocarbons (PAHs) removal from flue gas were investigated in the alcohol addition by using electron beam irradiation in EPS Kaweczyn. Experimental conditions were as follows: flue gas flow rate 5000 nM 3 /hr; humidity 4-5%; inlet concentrations of SO 2 and NO x , which were emitted from power station, were 192 ppm and 106 ppm, respectively; ammonia addition is 2.75 m 3 /hr; alcohol addition is 600 l/hr. It was found that NO x removal efficiency in the presence of alcohol was increased by 10% than without alcohol addition when the absorbed dose was below 6 kGy. The NO x removal efficiency was decreased when the absorbed dose was higher than 10 kGy. In order to understand PAHs' behavior under EB irradiation, inlet PAHs (emitted from coal combustion process) sample and outlet PAHs (after irradiation) sample were collected by using a condensed bottle connected with XAD-2 adsorbent and active carbon adsorbent and were analyzed by a GC-MS. It is found that: at the 8 kGy adsorbed dose, concentrations of PAHs with small aromatic rings (≤3, except Acenaphthylene) are reduced and concentrations of PAHs with large aromatic rings (≤4) are increased. A possible mechanism is proposed

  17. NOx removal from the flue gas of oil-fired boiler using a multistage plasma-catalyst hybrid system

    International Nuclear Information System (INIS)

    Park, Sung Youl; Deshwal, Bal Raj; Moon, Seung Hyun

    2008-01-01

    The study on removal of NO x from the flue gas of oil-fired boiler has been carried out using non-thermal plasma cum catalyst hybrid reactor at 150 C. Propylene (C 3 H 6 ) was used as a reducing agent. A multistage plasma-catalyst hybrid reactor was newly designed and successfully operated to clean up the flue gas stream having a flow rate of 30 Nm 3 /h. TiO 2 and Pd/ZrO 2 wash-coated on cordierite honeycomb were used as catalysts in the present study. Though the plasma-catalyst hybrid reactor with TiO 2 showed good activity on the removal of NO yet it removed only 50-60% of NO x because a significant portion of NO oxidized to NO 2 . On the contrary, the plasma-catalyst hybrid reactor with Pd/ZrO 2 removed about 50% of inlet NO with a negligible amount of NO oxidation into NO 2 . The plasma/dual-catalysts hybrid system (front two units of plasma-Pd/ZrO 2 + rear two units of plasma/TiO 2 ) proved to be very promising in NO x removal in the presence of C 3 H 6 . DeNO x efficiency of about 74% has been achieved at a space velocity of 3300/h at 150 C. (author)

  18. Control apparatus for hot gas engine

    Science.gov (United States)

    Stotts, Robert E.

    1986-01-01

    A mean pressure power control system for a hot gas (Stirling) engine utilizing a plurality of supply tanks for storing a working gas at different pressures. During pump down operations gas is bled from the engine by a compressor having a plurality of independent pumping volumes. In one embodiment of the invention, a bypass control valve system allows one or more of the compressor volumes to be connected to the storage tanks. By selectively sequencing the bypass valves, a capacity range can be developed over the compressor that allows for lower engine idle pressures and more rapid pump down rates.

  19. Electrospun metal oxide-TiO{sub 2} nanofibers for elemental mercury removal from flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Yuan; Zhao, Yongchun [State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Li, Hailong [State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); School of Energy Science and Engineering, Central South University, Changsha, Hunan 410083 (China); Li, Yang [State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); State Key Laboratory of Fine Chemicals, School of Chemical Engineering, Dalian University of Technology, Dalian, Liaoning 116024 (China); Gao, Xiang [State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou, Zhejiang 310027 (China); Zheng, Chuguang [State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Zhang, Junying, E-mail: jyzhang@hust.edu.cn [State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Developed the metal oxides (CuO, In{sub 2}O{sub 3}, V{sub 2}O{sub 5}, WO{sub 3} and Ag{sub 2}O) doped TiO{sub 2} nanofibers. Black-Right-Pointing-Pointer The fibers are applied to control Hg{sup 0} from coal combustion flue gas. Black-Right-Pointing-Pointer WO{sub 3} doped TiO{sub 2} exhibited the highest Hg{sup 0} removal efficiency of 100% under UV irradiation. Black-Right-Pointing-Pointer V{sub 2}O{sub 5} doped TiO{sub 2} greatly enhanced Hg{sup 0} removal under visible light irradiation. Black-Right-Pointing-Pointer TiO{sub 2}-Ag{sub 2}O showed a steady Hg{sup 0} removal efficiency of 95% without any light. - Abstract: Nanofibers prepared by an electrospinning method were used to remove elemental mercury (Hg{sup 0}) from simulated coal combustion flue gas. The nanofibers composed of different metal oxides (MO{sub x}) including CuO, In{sub 2}O{sub 3}, V{sub 2}O{sub 5}, WO{sub 3} and Ag{sub 2}O supported on TiO{sub 2} have been characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), energy dispersing X-ray (EDX) and UV-vis spectra. The average diameters of these nanofibers were about 200 nm. Compared to pure TiO{sub 2}, the UV-vis absorption intensity for MO{sub x}-TiO{sub 2} increased significantly and the absorption bandwidth also expanded, especially for Ag{sub 2}O-TiO{sub 2} and V{sub 2}O{sub 5}-TiO{sub 2}. Hg{sup 0} oxidation efficiencies over the MO{sub x}-TiO{sub 2} nanofibers were tested under dark, visible light (vis) irradiation and UV irradiation, respectively. The results showed that WO{sub 3} doped TiO{sub 2} exhibited the highest Hg{sup 0} removal efficiency of 100% under UV irradiation. Doping V{sub 2}O{sub 5} into TiO{sub 2} enhanced Hg{sup 0} removal efficiency greatly from 6% to 63% under visible light irradiation. Ag{sub 2}O doped TiO{sub 2} showed a steady Hg{sup 0} removal efficiency of around 95% without any light due to the formation of silver amalgam. An extended experiment

  20. Research progress of SO2 removal from flue gas by functionalized ionic liquids

    Directory of Open Access Journals (Sweden)

    Xinle SHI

    2017-02-01

    Full Text Available Functionalized ionic liquids are receiving increasing attention in the field of flue gas desulfurization due to its unique physical and chemical properties. Research progress on the field of SO2 removal by ionic liquids (ILs including guanidinium-based, amines-based and ether-based ILs is summarized. Industrial application of polymerization ILs and loaded ILs to desulfurization is reviewed. Relevant suggestions on industrial application of ionic liquids based on fundamental research are put forward. The first thing is to develop functional ionic liquid for desulfurization,and thus investigate and propose its desulfurization mechanism and model; the second is to carry out the research work on immobilized ionic liquid, and explore its recycling properties, thus prolonging its service life.

  1. Partial oxidation process for producing a stream of hot purified gas

    Science.gov (United States)

    Leininger, T.F.; Robin, A.M.; Wolfenbarger, J.K.; Suggitt, R.M.

    1995-03-28

    A partial oxidation process is described for the production of a stream of hot clean gas substantially free from particulate matter, ammonia, alkali metal compounds, halides and sulfur-containing gas for use as synthesis gas, reducing gas, or fuel gas. A hydrocarbonaceous fuel comprising a solid carbonaceous fuel with or without liquid hydrocarbonaceous fuel or gaseous hydrocarbon fuel, wherein said hydrocarbonaceous fuel contains halides, alkali metal compounds, sulfur, nitrogen and inorganic ash containing components, is reacted in a gasifier by partial oxidation to produce a hot raw gas stream comprising H{sub 2}, CO, CO{sub 2}, H{sub 2}O, CH{sub 4}, NH{sub 3}, HCl, HF, H{sub 2}S, COS, N{sub 2}, Ar, particulate matter, vapor phase alkali metal compounds, and molten slag. The hot raw gas stream from the gasifier is split into two streams which are separately deslagged, cleaned and recombined. Ammonia in the gas mixture is catalytically disproportionated into N{sub 2} and H{sub 2}. The ammonia-free gas stream is then cooled and halides in the gas stream are reacted with a supplementary alkali metal compound to remove HCl and HF. Alkali metal halides, vaporized alkali metal compounds and residual fine particulate matter are removed from the gas stream by further cooling and filtering. The sulfur-containing gases in the process gas stream are then reacted at high temperature with a regenerable sulfur-reactive mixed metal oxide sulfur sorbent material to produce a sulfided sorbent material which is then separated from the hot clean purified gas stream having a temperature of at least 1000 F. 1 figure.

  2. Fundamental mechanisms in flue-gas conditioning. Topical report No. 1, Literature review and assembly of theories on the interactions of ash and FGD sorbents

    Energy Technology Data Exchange (ETDEWEB)

    Dahlin, R.S.; Vann Bush, P.; Snyder, T.R.

    1992-01-09

    The overall goal of this research project is to formulate a mathematical model of flue gas conditioning. This model will be based on an understanding of why ash properties, such as cohesivity and resistivity, are changed by conditioning. Such a model could serve as a component of the performance models of particulate control devices where flue gas conditioning is used. There are two specific objectives of this research project, which divide the planned research into two main parts. One part of the project is designed to determine how ash particles are modified by interactions with sorbent injection processes and to describe the mechanisms by which these interactions affect fine particle collection. The objective of the other part of the project is to identify the mechanisms by which conditioning agents, including chemically active compounds, modify the key properties of fine fly ash particles.

  3. On the analysis of mercuric nitrate in flue gas by GC-MS

    Energy Technology Data Exchange (ETDEWEB)

    Olson, Edwin S.; Sharma, Ramesh K.; Pavlish, John H. [Energy and Environmental Research Center, University of North Dakota, Grand Forks, ND 58202 (United States)

    2002-11-01

    Recent research has demonstrated that in a simulated flue gas stream containing NO{sub 2} and SO{sub 2} elemental mercury is initially captured on a carbon or manganese oxide sorbent. After approximately an hour, however, mercury breaks through relatively rapidly, and the volatile form of mercury emitted is an oxidized species. The volatile mercury species emitted from a granular MnO{sub 2} sorbent was trapped in an impinger containing cold acetonitrile. Subsequent evaporation of 95% of the acetonitrile in a Kuderna-Danish apparatus and gas chromatography (GC) of the concentrate resulted in a single mercury-containing GC peak at 5.5 min; the retention time and mass spectrum of this compound matched exactly those of a standard mercury(II) nitrate hydrate, Hg(NO{sub 3}){sub 2}.H{sub 2}O dissolved in acetonitrile. The volatile mercury component analyzed from injection of this standard solution was shown to be a form of methylmercury that is produced in the GC column by reaction of the highly reactive mercury nitrate with the methylsiloxane GC phase. Because the on-column derivatization reaction seems to be unique to mercury nitrate, the GC-MS (gas chromatography-mass spectroscopic) analysis provides strong evidence for identification of the trapped oxidized mercury species as mercury nitrate although, because the nitrate becomes detached from the mercury atom in the on-column reaction, the identity is not proven. (orig.)

  4. Simulation of the operation of an industrial wet flue gas desulfurization system

    International Nuclear Information System (INIS)

    Kallinikos, L.E.; Farsari, E.I.; Spartinos, D.N.; Papayannakos, N.G.

    2010-01-01

    In this work the simulation of a wet flue gas desulfurization (FGD) unit with spray tower of a power plant is presented, aiming at an efficient follow-up and the optimization of the FGD system operation. The dynamic model developed to simulate the performance of the system has been validated with operation data collected over a long period of time. All the partaking physical and chemical processes like the limestone dissolution, the crystallization of calcium sulfite and gypsum and the oxidation of sulfite ions have been taken into account for the development of the simulation model while the gas absorption by the liquid droplets was based on the two-film theory. The effect of the mean diameter of the slurry droplets on the performance of the system was examined, as it was used as an index factor of the normal operation of the system. The operation limits of the system were investigated on the basis of the model developed. It is concluded that the model is capable of simulating the system for significantly different SO 2 loads and that the absorption rate of SO 2 is strongly affected by the liquid dispersion in the tower. (author)

  5. Separation of submicron particles from biofuel combustion with flue gas condensation or wet condensing electrostatic precipitator. Analysis of possibilities; Avskiljning av submikrona partiklar vid biobraenslefoerbraenning med roekgaskondensering eller kondenserande vaata elfilter. Analys av moejligheterna

    Energy Technology Data Exchange (ETDEWEB)

    Roennbaeck, Marie; Gustavsson, Lennart [Swedish National Testing and Research Inst., Boraas (Sweden)

    2006-11-15

    Dust particles in flue gas larger than 1 {mu}m are well separated by conventional techniques, while submicron particles are poorly separated. As the use of biofuels with high ash content is increasing, as well as knowledge about negative health effects from inhalation of submicron particles, the interest for reduction of emissions of submicron particles will probably increase. The aim of this project is to investigate possible techniques for separation of submicron particles during flue gas condensation through modification of conventional technique, or with available techniques not usually used with combustion of biofuels, e.g. a wet electrostatic precipitator. Mechanisms for separation of dust particles are briefly described. Cyclones separates particles larger than about 1 {mu}m. Fabric filters separates all particles sizes, but the efficiency reduces as the size reduces. In flue gas condensers and scrubbers the speed and size of water droplets are important for the reduction efficiency. Dry electrostatic precipitators work for all particle sizes, but with reduced efficiency for sizes between 0.1 and 3 {mu}m. Wet electrostatic precipitators separates submicron particles much better. One reason for this is that the potential between the electrodes can be higher. Among conventional flue gas condensers and scrubbers there are two types that, properly designed, can separate submicron particles, namely 'type venturi scrubbers', i.e. a scrubber where a high flue gas velocity is used to form many, small water droplets by friction forces in a nozzle, and 'type scrubber with nozzles', i.e. a scrubber where nozzles supply droplets to the flue gas. For a scrubber with nozzles, the falling velocity of the droplets must be lower and the size smaller than is common today. Also the wet electrostatic precipitator separates submicron particles with high efficiency. They are used today mainly for problematic particles, e.g. sticky or corrosive ones, or for

  6. Experimental study on Hg{sup 0} removal from flue gas over columnar MnO{sub x}-CeO{sub 2}/activated coke

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Yine [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control, Hunan University, Ministry of Education, Changsha 410082 (China); Li, Caiting, E-mail: ctli@hnu.edu.cn [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control, Hunan University, Ministry of Education, Changsha 410082 (China); Zhao, Lingkui; Zhang, Jie; Zeng, Guangming; Zhang, Xunan; Zhang, Wei; Tao, Shasha [College of Environmental Science and Engineering, Hunan University, Changsha 410082 (China); Key Laboratory of Environmental Biology and Pollution Control, Hunan University, Ministry of Education, Changsha 410082 (China)

    2015-04-01

    Highlights: • The Hg{sup 0} removal efficiency over columnar MnCe6/activated coke up to 94%. • MnO{sub x} and CeO{sub 2} exhibited a significant synergistic role in Hg{sup 0} removal over MnCe/AC. • Lattice oxygen, chemisorbed oxygen and OH groups on the surface of MnCe/AC contributed to Hg{sup 0} oxidation. • Hg{sup 0} removal mechanisms over MnCe/AC were identified firstly. - Abstract: Mn-Ce mixed oxides supported on commercial columnar activated coke (MnCe/AC) were employed to remove elemental mercury (Hg{sup 0}) at low temperatures (100–250 °C) without the assistance of HCl in flue gas. The samples were characterized by X-ray diffraction (XRD), Brunauer–Emmett–Teller (BET), X-ray photoelectron spectroscopy (XPS) and temperature programmed desorption (TPD). Effects of some factors, including Mn-Ce loading values, active component, reaction temperatures and flue gas components (O{sub 2}, SO{sub 2}, NO, H{sub 2}O), on Hg{sup 0} removal efficiency were investigated. Results indicated that the optimal Mn-Ce loading value and reaction temperature were 6% and 190 °C, respectively. Considerable high Hg{sup 0} removal efficiency (>90%) can be obtained over MnCe6/AC under both N{sub 2}/O{sub 2} atmosphere and simulated flue gas atmosphere at 190 °C. Besides, it was observed that O{sub 2} and NO exerted a promotional effect on Hg{sup 0} removal, H{sub 2}O exhibited a suppressive effect, and SO{sub 2} hindered Hg{sup 0} removal seriously when in the absence of O{sub 2}. Furthermore, the XPS spectra of Hg 4f and Hg-TPD results showed that the captured mercury were existed as Hg{sup 0} and HgO on the MnCe6/AC, and HgO was the major species, which illustrated that adsorption and catalytic oxidation process were included for Hg{sup 0} removal over MnCe6/AC, and catalytic oxidation played the critical role. What's more, both lattice oxygen and chemisorbed oxygen or OH groups on MnCe6/AC contributed to Hg{sup 0} oxidation. MnCe6/AC, which exhibited

  7. Gas manufacture

    Energy Technology Data Exchange (ETDEWEB)

    Fell, J W

    1915-05-03

    Retorts for the distillation of shale or coal for the production of oil or illuminating-gas are heated by gas from a generator or a gas-holder, and a portion of the gas from the flue leading to the heating-flues is forced by a steam jet through a by-pass and is injected into the bottom of the retorts. If the gas to be admitted to the retort is cold, it is first heated.

  8. Surprisingly low natural gas consumption for hot water in the Netherlands in 1996

    International Nuclear Information System (INIS)

    Geerse, C.

    1997-01-01

    The Dutch use hot water more efficient than previously expected. This conclusion is drawn from a recent study of hot water consumption in Dutch households and the corresponding natural gas consumption. Based on that (once-only) hot water use survey the hot water use models, as applied in the annual Basic Survey of Natural Gas Consumption of Small-scale Consumers in the Netherlands (BAK), will be modified. 6 tabs

  9. Study of flue gas condensers with reference to corrosion risks, biofuel quality, techniques and choice of material; Kartlaeggning av roekgaskondenseringsanlaeggningar med avseende paa korrosionsrisker, biobraenslekvaliteter, teknik och materialval

    Energy Technology Data Exchange (ETDEWEB)

    Stenqvist, Per-Aake

    2012-02-15

    Corrosion in flue gas appliances installed in small and medium sized biomass fired boiler plants has become a problem in an increasing number of sites around Sweden. A trend seems to be that the problems are greater in those plants that use so called terminal chips than those that utilize more homogeneous fuels. In pace with the increasing number of biomass power plants in the country, the demand for cheaper fuel is increased. Through the increasing number of fuel terminals the market is provided even with biofuel mixes in the form of traditional wood chips mixed with bark, forest residue, sawdust, willow, returned wood, etc. Both users and suppliers of boiler and flue gas systems, and fuel suppliers have currently no clear rules or guidelines for relationships between different chemical properties of fuels, technologies, operating data and material. In this report has experience in the form of questionnaires completed by field visits, interviews of operational personnel and literature studies been compiled from a number of plants using different types of flue gas condensers for increased energy output from various types of bio fuels. The purpose of this assignment is to survey the flue gas condensation plant in biomass fired boiler plants for the presence of corrosion damage made in relation to the use of technologies and fuel qualities. A milestone is that the report will be able to be used to support the selection of materials and appropriate techniques for both new facilities and for the repair and improvement of existing ones. Another objective is to compile existing experience and assessment criteria which are reported in the literature. This report describes some typical construction techniques, whenever applicable harmful images and links to various substances present in fuels, ash and condensate

  10. Dynamic measurement of mercury adsorption and oxidation on activated carbon in simulated cement kiln flue gas

    DEFF Research Database (Denmark)

    Zheng, Yuanjing; Jensen, Anker Degn; Windelin, Christian

    2012-01-01

    of the sulfite converter is short and typically within 2min. Dynamic mercury adsorption and oxidation tests on commercial activated carbons Darco Hg and HOK standard were performed at 150°C using simulated cement kiln gas and a fixed bed reactor system. It is shown that the converter and analyzer system...... are still under development and are investigated in this work. A commercial red brass converter was tested at 180°C and it was found that the red brass chips work in nitrogen atmosphere only, but do not work properly under simulated cement kiln flue gas conditions. Test of the red brass converter using only...... elemental mercury shows that when HCl is present with either SO2 or NOx the mercury measurement after the converter is unstable and lower than the elemental mercury inlet level. The conclusion is that red brass chips cannot fully reduce oxidized mercury to elemental mercury when simulated cement kiln gas...

  11. Hydroquinone and Quinone-Grafted Porous Carbons for Highly Selective CO2 Capture from Flue Gases and Natural Gas Upgrading.

    Science.gov (United States)

    Wang, Jun; Krishna, Rajamani; Yang, Jiangfeng; Deng, Shuguang

    2015-08-04

    Hydroquinone and quinone functional groups were grafted onto a hierarchical porous carbon framework via the Friedel-Crafts reaction to develop more efficient adsorbents for the selective capture and removal of carbon dioxide from flue gases and natural gas. The oxygen-doped porous carbons were characterized with scanning electron microscopy, transmission electron microscopy, X-ray powder diffraction, Fourier transform infrared spectroscopy, and Raman spectroscopy. CO2, CH4, and N2 adsorption isotherms were measured and correlated with the Langmuir model. An ideal adsorbed solution theory (IAST) selectivity for the CO2/N2 separation of 26.5 (298 K, 1 atm) was obtained on the hydroquinone-grafted carbon, which is 58.7% higher than that of the pristine porous carbon, and a CO2/CH4 selectivity value of 4.6 (298 K, 1 atm) was obtained on the quinone-grafted carbon (OAC-2), which represents a 28.4% improvement over the pristine porous carbon. The highest CO2 adsorption capacity on the oxygen-doped carbon adsorbents is 3.46 mmol g(-1) at 298 K and 1 atm. In addition, transient breakthrough simulations for CO2/CH4/N2 mixture separation were conducted to demonstrate the good separation performance of the oxygen-doped carbons in fixed bed adsorbers. Combining excellent adsorption separation properties and low heats of adsorption, the oxygen-doped carbons developed in this work appear to be very promising for flue gas treatment and natural gas upgrading.

  12. Silicon carbide based sensor system for minimized emissions in flue gases; Kiselkarbidbaserat sensorsystem foer minimering av emissioner i roekgaser

    Energy Technology Data Exchange (ETDEWEB)

    Lloyd Spetz, Anita; Bjorklund, Robert

    2012-02-15

    Control of the combustion process is necessary in order to operate boilers in an economic and environmentally acceptable manner. Large power plants can afford expensive measurement instruments to continuously monitor the composition of flue gas. Smaller facilities often lack complete gas analysis systems and it would be to their advantage to have access to inexpensive measurement equipment which could be installed at several points in the flue gas channel. Since oxygen concentration is such an important parameter for describing the combustion process the lambdasond is currently being used as an oxygen sensor in flue gas. It has the advantage of usage for more than 30 years in the automobile industry. Experience from that application has aided its introduction in the power industry. Conditions are not the same in the two branches but the lambdasond is an established technology, produced in large volume, widely available and inexpensive. Vehicle manufacturers continue to develop sensor technology and monitoring capabilities have been extended to CO, NOx and NH3. The latter is the result of SCR (selective catalytic reduction) of NOx by addition of NH3 (from urea), which has been introduced as an exhaust gas aftertreatment technology in diesel powered vehicles. The power industry can be expected to follow this trend by incorporating sensors for monitoring and control of SCR and SNCR (non-catalytic selective reduction) in flue gas applications. This report describes evaluation of silicon carbide based transistors, which have previously been studied in diesel exhaust gas and small boiler flue gas, for applications in larger power plants

  13. Fractionation of mercury stable isotopes during coal combustion and seawater flue gas desulfurization

    International Nuclear Information System (INIS)

    Huang, Shuyuan; Yuan, Dongxing; Lin, Haiying; Sun, Lumin; Lin, Shanshan

    2017-01-01

    In the current study, fractionation of mercury isotopes during coal combustion and seawater flue gas desulfurization (SFGD) in a coal-fired power plant using a SFGD system was investigated. Fourteen samples were collected from the power plant. The samples were pretreated with a combustion-trapping method and were analyzed with a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS). Compared with the raw coal, the bottom ash was enriched with lighter mercury isotopes with δ 202 Hg values ranging from −0.45 to −0.03‰. The fly ash was enriched with lighter mercury isotopes with δ 202 Hg values ranging from −1.49 to −0.73‰ for Chinese coal and from −1.47 to −0.62‰ for Indonesian coal. The δ 202 Hg of fresh seawater and desulfurized seawater was found to be −1.32 and −0.32‰ respectively. These δ 202 Hg values indicated that the desulfurized seawater was enriched with heavier mercury isotopes. Based upon the calculated results obtained from the mass balance equation, it was suggested that the stack emissions were enriched with lighter mercury isotopes. Mass independent fractionation was observed in most of the samples with a Δ 199 Hg/Δ 201 Hg ratio of approximately 0.96. The results help in improving the understanding of mercury isotope fractionation during coal combustion and SFGD, and are also useful in tracing the mercury emissions from coal fired power plants. - Highlights: • Spread of 1.5‰ was observed in δ 202 Hg values of raw coals and coal related samples. • The δ 202 Hg values were more negative in fly ash than those in the raw coal. • The flue gas had a significant Hg fractionation after desulfurization. • The stack emissions were enriched with lighter isotopes compared with the raw coal.

  14. Fuel saving, carbon dioxide emission avoidance, and syngas production by tri-reforming of flue gases from coal- and gas-fired power stations, and by the carbothermic reduction of iron oxide

    International Nuclear Information System (INIS)

    Halmann, M.; Steinfeld, A.

    2006-01-01

    Flue gases from coal, gas, or oil-fired power stations, as well as from several heavy industries, such as the production of iron, lime and cement, are major anthropogenic sources of global CO 2 emissions. The newly proposed process for syngas production based on the tri-reforming of such flue gases with natural gas could be an important route for CO 2 emission avoidance. In addition, by combining the carbothermic reduction of iron oxide with the partial oxidation of the carbon source, an overall thermoneutral process can be designed for the co-production of iron and syngas rich in CO. Water-gas shift (WGS) of CO to H 2 enables the production of useful syngas. The reaction process heat, or the conditions for thermoneutrality, are derived by thermochemical equilibrium calculations. The thermodynamic constraints are determined for the production of syngas suitable for methanol, hydrogen, or ammonia synthesis. The environmental and economic consequences are assessed for large-scale commercial production of these chemical commodities. Preliminary evaluations with natural gas, coke, or coal as carbon source indicate that such combined processes should be economically competitive, as well as promising significant fuel saving and CO 2 emission avoidance. The production of ammonia in the above processes seems particularly attractive, as it consumes the nitrogen in the flue gases

  15. HGR: Flow models, dust cake and cleaning models for hot flue gas filters. Project part: Design, flow regimes and cleaning of dust cakes at high temperatures. Final report; HGR: Stroemungs-, Filterkuchen- und Abreinigungsmodelle fuer Heissgasfilter. Teilprojekt: Aufbau, Durchstroemung und Abreinigung von Filterkuchen bei hohen Temperaturen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hemmer, G.

    1998-12-31

    As separators for the dedusting of hot flue gases from pressurized coal combustion or from product gases of coal gasification there are in principle filtration and centrifugal force and electrical separators. In this project bases shall be determined for methods of interpretation, carcateristic quantities and guide values for the hot gas filtration. As primary sizes for the interpretation to filter plants the pressure drop of dust cakes and filter elements on one hand and the forces necessary for regeneration on the other hand are of fundamental importance. Measurements were carried out at a high temperature filtration unit and at a laboratory filter plant and completed at a high temperature shear cell and a dilatometer. It was shown that the material composition of the dusts has a very decisive influence. Furthermore, the relative humidity has a considerable influence at ambient temperature. Aims of further examinations should therefore be the quantification of the material influences and the meaning of water vapour at high temperatures in order to be able to develop methods of interpretation for hot gas filters. (orig.) [Deutsch] Als Abscheideprinzipien fuer die Entstaubung von heissen Rauchgasen aus der Kohledruckverbrennung oder von Produktgasen aus der Kohlevergasung kommen Filtrations-, Fliehkraft- und elektrische Abscheider in Frage. In diesem Projekt sollen fuer die Heissgasfiltration Grundlagen fuer die Auslegungsmethoden, Kenngroessen und Richtwerte ermittelt werden. Als Primaergroessen fuer die Auslegung von Filteranlagen sind der Druckverlust von Staubkuchen und Filterelement einerseits und die zur Abreinigung noetige Abreinigungsintensitaet andererseits einzuschaetzen. Dabei wurden Messungen an einer Hochtemperaturfiltrationsanlage und einer Laborfilteranlage durchgefuehrt und durch Untersuchungen an einer Hochtemperaturscherzelle und einem Dilatometer ergaenzt. Es zeigte sich, dass die stoffliche Zusammensetzung der Staeube einen sehr entscheidenden

  16. Industrial applications of electron beam flue gas treatment - From laboratory to the practice

    International Nuclear Information System (INIS)

    Chmielewski, Andrzej G.

    2007-01-01

    The electron beam technology for flue gas treatment (EBFGT) has been developed in Japan in the early 1980s. Later on, this process was investigated in pilot scale in the USA, Germany, Japan, Poland, Bulgaria and China. The new engineering and process solutions have been developed during the past two decades. Finally industrial plants have been constructed in Poland and China. The high efficiency of SO x and NO x removal was achieved (up to 95% for SO x and up to 70% for NO x ) and by-product is a high quality fertilizer. Since the power of accelerators applied in industrial installation is over 1 MW and requested operational availability of the plant is equal to 8500 h in year, it is a new challenge for radiation processing applications

  17. Selective gas absorption by ionic liquids

    DEFF Research Database (Denmark)

    Shunmugavel, Saravanamurugan; Kegnæs, Søren; Due-Hansen, Johannes

    2010-01-01

    Reversible absorption performance for the flue gas components CO 2, NO and SO2 has been tested for several different ionic liquids (ILs) at different temperatures and flue gas compositions. Furthermore, different porous, high surface area carriers have been applied as supports for the ionic liquids...... to obtain Supported Ionic Liquid-Phase (SILP) absorber materials. The use of solid SILP absorbers with selected ILs were found to significantly improve the absorption capacity and sorption dynamics at low flue gas concentration, thus making the applicability of ILs viable in technical, continuous flow...... processes for flue gas cleaning. The results show that CO 2, NO and SO2 can be reversible and selective absorbed using different ILs and that Supported Ionic Liquid-Phase (SILP) absorbers are promising materials for industrial flue gas cleaning. Absorption/desorption dynamics can be tuned by temperatures...

  18. Integrated strategy for N-methylformanilide production from carbon dioxide of flue gas in coal-fired power plant

    International Nuclear Information System (INIS)

    Han, Jeehoon

    2017-01-01

    Highlights: • A ‘green’ N-methylformanilide production process based new carbon dioxide conversion technologies is developed. • Monoethanolamine-based system for capturing carbon dioxide from the flue gas of a coal-fired power plant is deployed. • Gamma-valerolactone is used a solvent and catalyst for converting carbon dioxide to N-methylformanilide. • New separations for recovery of N-methylformanilide and gamma-valerolactone are developed. • Economic evaluation of the proposed process is performed. - Abstract: In this work, an integrated strategy is developed for producing N-methylformanilide from the carbon dioxide of flue gas in a coal-fired power plant. Based on lab-scale experimental studies presenting maximum yields (96%) with low reaction concentrations (below 25 wt% reactants) using large volumes of gamma-valerolactone as a solvent and catalyst, the integrated strategy focuses on the development of commercial-scale processes that consist of a monoethanolamine-based carbon dioxide separation subsystem and a catalytic conversion subsystem of N-Methylaniline with carbon dioxide to N-methylformanilide. Moreover, a heat exchanger network is designed to minimize the total energy requirements by transferring the heat between subsystems. In the proposed integrated strategy, the energy efficiency after heat integration (77.5%) is higher than that before heat integration (74.5%). Economic analysis results show that the minimum selling price of N-methylformanilide ($1592.1 Mt"−"1 using the best possible parameters) for use in this integrated strategy is cost-competitive with the current market price ($2984 Mt"−"1).

  19. Long-time experience in catalytic flue gas cleaning and catalytic NO{sub x} reduction in biofueled boilers

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, M [Tampella Power Inc., Tampere (Finland)

    1997-12-31

    NO emissions are reduced by primary or secondary methods. Primary methods are based on NO reduction in the combustion zone and secondary methods on flue gas cleaning. The most effective NO reduction method is selective catalytic reduction (SCR). It is based on NO reduction by ammonia on the surface of a catalyst. Reaction products are water and nitrogen. A titanium-dioxide-based catalyst is very durable and selective in coal-fired power plants. It is not poisoned by sulphur dioxide and side reactions with ammonia and sulphur dioxide hardly occur. The long time experience and suitability of a titanium-dioxide-based catalyst for NO reduction in biofuel-fired power plants was studied. The biofuels were: peat, wood and bark. It was noticed that deactivation varied very much due to the type of fuel and content of alkalinities in fuel ash. The deactivation in peat firing was moderate, close to the deactivation noticed in coal firing. Wood firing generally had a greater deactivation effect than peat firing. Fuel and fly ash were analyzed to get more information on the flue gas properties. The accumulation of alkali and alkaline earth metals and sulphates was examined together with changes in the physical composition of the catalysts. In the cases where the deactivation was the greatest, the amount of alkali and alkaline earth metals in fuels and fly ashes and their accumulation were very significant. (author) (3 refs.)

  20. Long-time experience in catalytic flue gas cleaning and catalytic NO{sub x} reduction in biofueled boilers

    Energy Technology Data Exchange (ETDEWEB)

    Ahonen, M. [Tampella Power Inc., Tampere (Finland)

    1996-12-31

    NO emissions are reduced by primary or secondary methods. Primary methods are based on NO reduction in the combustion zone and secondary methods on flue gas cleaning. The most effective NO reduction method is selective catalytic reduction (SCR). It is based on NO reduction by ammonia on the surface of a catalyst. Reaction products are water and nitrogen. A titanium-dioxide-based catalyst is very durable and selective in coal-fired power plants. It is not poisoned by sulphur dioxide and side reactions with ammonia and sulphur dioxide hardly occur. The long time experience and suitability of a titanium-dioxide-based catalyst for NO reduction in biofuel-fired power plants was studied. The biofuels were: peat, wood and bark. It was noticed that deactivation varied very much due to the type of fuel and content of alkalinities in fuel ash. The deactivation in peat firing was moderate, close to the deactivation noticed in coal firing. Wood firing generally had a greater deactivation effect than peat firing. Fuel and fly ash were analyzed to get more information on the flue gas properties. The accumulation of alkali and alkaline earth metals and sulphates was examined together with changes in the physical composition of the catalysts. In the cases where the deactivation was the greatest, the amount of alkali and alkaline earth metals in fuels and fly ashes and their accumulation were very significant. (author) (3 refs.)

  1. The co-existence of hot and cold gas in debris discs

    Science.gov (United States)

    Rebollido, I.; Eiroa, C.; Montesinos, B.; Maldonado, J.; Villaver, E.; Absil, O.; Bayo, A.; Canovas, H.; Carmona, A.; Chen, Ch.; Ertel, S.; Garufi, A.; Henning, Th.; Iglesias, D. P.; Launhardt, R.; Liseau, R.; Meeus, G.; Moór, A.; Mora, A.; Olofsson, J.; Rauw, G.; Riviere-Marichalar, P.

    2018-06-01

    Context. Debris discs have often been described as gas-poor discs as the gas-to-dust ratio is expected to be considerably lower than in primordial, protoplanetary discs. However, recent observations have confirmed the presence of a non-negligible amount of cold gas in the circumstellar (CS) debris discs around young main-sequence stars. This cold gas has been suggested to be related to the outgassing of planetesimals and cometary-like objects. Aims: The goal of this paper is to investigate the presence of hot gas in the immediate surroundings of the cold-gas-bearing debris-disc central stars. Methods: High-resolution optical spectra of all currently known cold-gas-bearing debris-disc systems, with the exception of β Pic and Fomalhaut, have been obtained from La Palma (Spain), La Silla (Chile), and La Luz (Mexico) observatories. To verify the presence of hot gas around the sample of stars, we have analysed the Ca II H&K and the Na I D lines searching for non-photospheric absorptions of CS origin, usually attributed to cometary-like activity. Results: Narrow, stable Ca II and/or Na I absorption features have been detected superimposed to the photospheric lines in 10 out of the 15 observed cold-gas-bearing debris-disc stars. Features are found at the radial velocity of the stars, or slightly blue- or red-shifted, and/or at the velocity of the local interstellar medium (ISM). Some stars also present transient variable events or absorptions extended towards red wavelengths (red wings). These are the first detections of such Ca II features in 7 out of the 15 observed stars. Although an ISM origin cannot categorically be excluded, the results suggest that the stable and variable absorptions arise from relatively hot gas located in the CS close-in environment of the stars. This hot gas is detected in at least 80%, of edge-on cold-gas-bearing debris discs, while in only 10% of the discs seen close to face-on. We interpret this result as a geometrical effect, and suggest

  2. Power control system for a hot gas engine

    Science.gov (United States)

    Berntell, John O.

    1986-01-01

    A power control system for a hot gas engine of the type in which the power output is controlled by varying the mean pressure of the working gas charge in the engine has according to the present invention been provided with two working gas reservoirs at substantially different pressure levels. At working gas pressures below the lower of said levels the high pressure gas reservoir is cut out from the control system, and at higher pressures the low pressure gas reservoir is cut out from the system, thereby enabling a single one-stage compressor to handle gas within a wide pressure range at a low compression ratio.

  3. Mixotrophic cultivation of a microalga Scenedesmus obliquus in municipal wastewater supplemented with food wastewater and flue gas CO2 for biomass production.

    Science.gov (United States)

    Ji, Min-Kyu; Yun, Hyun-Shik; Park, Young-Tae; Kabra, Akhil N; Oh, In-Hwan; Choi, Jaeyoung

    2015-08-15

    The biomass and lipid/carbohydrate production by a green microalga Scenedesmus obliquus under mixotrophic condition using food wastewater and flue gas CO2 with municipal wastewater was investigated. Different dilution ratios (0.5-2%) of municipal wastewater with food wastewater were evaluated in the presence of 5, 10 and 14.1% CO2. The food wastewater (0.5-1%) with 10-14.1% CO2 supported the highest growth (0.42-0.44 g L(-1)), nutrient removal (21-22 mg TN L(-1)), lipid productivity (10-11 mg L(-1)day(-1)) and carbohydrate productivity (13-16 mg L(-1)day(-1)) by S. obliquus after 6 days of cultivation. Food wastewater increased the palmitic and oleic acid contents up to 8 and 6%, respectively. Thus, application of food wastewater and flue gas CO2 can be employed for enhancement of growth, lipid/carbohydrate productivity and wastewater treatment efficiency of S. obliquus under mixotrophic condition, which can lead to development of a cost effective strategy for microalgal biomass production. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. DYNAMIC S0 GALAXIES. II. THE ROLE OF DIFFUSE HOT GAS

    International Nuclear Information System (INIS)

    Li Jiangtao; Chen Yang; Daniel Wang, Q.; Li Zhiyuan

    2011-01-01

    Cold gas loss is thought to be important in star formation quenching and morphological transition during the evolution of S0 galaxies. In high-density environments, this gas loss can be achieved via many external mechanisms. However, in relatively isolated environments, where these external mechanisms cannot be efficient, the gas loss must then be dominated by some internal processes. We have performed Chandra analysis of hot gas in five nearby isolated S0 galaxies, based on the quantitative subtraction of various stellar contributions. We find that all the galaxies studied in the present work are X-ray faint, with the luminosity of the hot gas (L X ) typically accounting for ∼ X at the low-mass end (typically with K-band luminosity L K ∼ 11 L sun,K ). However, at the high-mass end, S0 galaxies tend to have significantly lower L X than elliptical galaxies of the same stellar masses, as already shown in previous observational and theoretical works. We further discuss the potential relationship of the diffuse X-ray emission with the cold (atomic and molecular) gas content in the S0 and elliptical galaxies included in our study. We find that L X /L 2 K tends to correlate positively with the total cold gas mass (M H 2 +H i ) for cold-gas-poor galaxies with M H 2 +H i ∼ 8 M sun , while they anti-correlate with each other for cold-gas-rich galaxies. This cold-hot gas relationship can be explained in a scenario of early-type galaxy evolution, with the leftover cold gas from the precursor star-forming galaxy mainly removed by the long-lasting Type Ia supernova (SN) feedback. The two different trends for cold-gas-rich and cold-gas-poor galaxies may be the results of the initial fast decreasing SN rate and the later fast decreasing mass loading to hot gas, respectively.

  5. Electricity of Vietnam and problem of flue gases

    International Nuclear Information System (INIS)

    Tran Khac An

    2005-01-01

    After reporting the present status and development of electricity in Vietnam, the author points out the most pollutant source is coal-fired power plants followed by listing pollutant substances by coal, oil and gas fired plants and Vietnamese standards of industrial emission and ambient air quality. To conclude, it is time to prepare staff and technology for the utilization of electron accelerators to flue gas treatment. (S. Ohno)

  6. BENCH-SCALE DEMONSTRATION OF HOT-GAS DESULFURIZATION TECHNOLOGY

    International Nuclear Information System (INIS)

    Unknown

    1999-01-01

    The U.S. Department of Energy (DOE), Federal Energy Technology Center (FETC), is sponsoring research in advanced methods for controlling contaminants in hot coal gasifier gas (coal-derived fuel-gas) streams of integrated gasification combined-cycle (IGCC) power systems. The hot gas cleanup work seeks to eliminate the need for expensive heat recovery equipment, reduce efficiency losses due to quenching, and minimize wastewater treatment costs. Hot-gas desulfurization research has focused on regenerable mixed-metal oxide sorbents that can reduce the sulfur in coal-derived fuel-gas to less than 20 ppmv and can be regenerated in a cyclic manner with air for multicycle operation. Zinc titanate (Zn(sub 2) TiO(sub 4) or ZnTiO(sub 3)), formed by a solid-state reaction of zinc oxide (ZnO) and titanium dioxide (TiO(sub 2)), is currently one of the leading sorbents. Overall chemical reactions with Zn(sub 2) TiO(sub 4) during the desulfurization (sulfidation)-regeneration cycle are shown below: Sulfidation: Zn(sub 2) TiO(sub 4)+ 2H(sub 2)S(yields) 2ZnS+ TiO(sub 2)+ 2H(sub 2)O; Regeneration: 2ZnS+ TiO(sub 2)+ 3O(sub 2)(yields) Zn(sub 2) TiO(sub 4)+ 2SO(sub 2) The sulfidation/regeneration cycle can be carried out in a fixed-bed, moving-bed, or fluidized-bed reactor configuration. The fluidized-bed reactor configuration is most attractive because of several potential advantages including faster kinetics and the ability to handle the highly exothermic regeneration to produce a regeneration offgas containing a constant concentration of SO(sub 2)

  7. Mathematical Model of Two Phase Flow in Natural Draft Wet-Cooling Tower Including Flue Gas Injection

    Directory of Open Access Journals (Sweden)

    Hyhlík Tomáš

    2016-01-01

    Full Text Available The previously developed model of natural draft wet-cooling tower flow, heat and mass transfer is extended to be able to take into account the flow of supersaturated moist air. The two phase flow model is based on void fraction of gas phase which is included in the governing equations. Homogeneous equilibrium model, where the two phases are well mixed and have the same velocity, is used. The effect of flue gas injection is included into the developed mathematical model by using source terms in governing equations and by using momentum flux coefficient and kinetic energy flux coefficient. Heat and mass transfer in the fill zone is described by the system of ordinary differential equations, where the mass transfer is represented by measured fill Merkel number and heat transfer is calculated using prescribed Lewis factor.

  8. Gas-heating alternatives to the residential electric heat pump. Gas Appliance Technology Center 1987 program. Topical report for Work Area 1.1, October 1989-March 1990

    International Nuclear Information System (INIS)

    Haas, C.

    1990-05-01

    The characteristics of electric heat pumps are described. Options are defined and assessed for utilizing gas heating in conjunction with existing residential electric heat pumps. These options include gas heat introduced into the refrigeration circuit, a flue gas-heated tube bank in the air supply duct, and a hot-water-to-air coil in the supply duct. Economics are presented for conversion of a residence's total space and water heating from electric to gas in New York City and Atlanta. Potential marketing strategies are discussed, and potential gas sales volumes from conversions are estimated. The study concludes that the use of gas water heating coupled with a hydronic coil in the supply ductwork from the air handler is the most advantageous option for the gas industry

  9. CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS

    International Nuclear Information System (INIS)

    David A. Green; Brian S. Turk; Raghubir P. Gupta; William J. McMichael; Douglas P. Harrison; Ya Liang

    2002-01-01

    The objective of this project is to develop a simple, inexpensive process to separate CO(sub 2) as an essentially pure stream from a fossil fuel combustion system using a regenerable, sodium-based sorbent. The sorbents being investigated in this project are primarily alkali carbonates, and particularly sodium carbonate and potassium carbonate, which are converted to bicarbonates, through reaction with carbon dioxide and water vapor. Bicarbonates are regenerated to carbonates when heated, producing a nearly pure CO(sub 2) stream after condensation of water vapor. This quarter, electrobalance tests conducted at LSU indicated that exposure of sorbent to water vapor prior to contact with carbonation gas does not significantly increase the reaction rate. Calcined fine mesh trona has a greater initial carbonation rate than calcined sodium bicarbonate, but appears to be more susceptible to loss of reactivity under severe calcination conditions. The Davison attrition indices for Grade 5 sodium bicarbonate, commercial grade sodium carbonate and extra fine granular potassium carbonate were, as tested, outside of the range suitable for entrained bed reactor testing. Fluidized bed testing at RTI indicated that in the initial stages of reaction potassium carbonate removed 35% of the carbon dioxide in simulated flue gas, and is reactive at higher temperatures than sodium carbonate. Removals declined to 6% when 54% of the capacity of the sorbent was exhausted. Carbonation data from electrobalance testing was correlated using a shrinking core reaction model. The activation energy of the reaction of sodium carbonate with carbon dioxide and water vapor was determined from nonisothermal thermogravimetry

  10. The Interaction of Hot and Cold Gas in the Disk and Halo of Galaxies

    Science.gov (United States)

    Slavin, Jonathan; Salamon, Michael (Technical Monitor)

    2004-01-01

    Most of the thermal energy in the Galaxy and perhaps most of the baryons in the Universe are found in hot (log T approximately 5.5 - 7) gas. Hot gas is detected in the local interstellar medium, in supernova remnants (SNR), the Galactic halo, galaxy clusters and the intergalactic medium (IGM). In our own Galaxy, hot gas exists in large superbubbles up to several hundred pc in diameter that locally dominate the interstellar medium (ISM) and determine its thermal and dynamic evolution. While X-ray observations using ROSAT, Chandra and XMM have allowed us to make dramatic progress in mapping out the morphology of the hot gas and in understanding some of its spectral characteristics, there remain fundamental questions that are unanswered. Chief among these questions is the way that hot gas interacts with cooler phase gas and the effects these interactions have on hot gas energetics. The theoretical investigations we proposed in this grant aim to explore these interactions and to develop observational diagnostics that will allow us to gain much improved information on the evolution of hot gas in the disk and halo of galaxies. The first of the series of investigations that we proposed was a thorough exploration of turbulent mixing layers and cloud evaporation. We proposed to employ a multi-dimensional hydrodynamical code that includes non-equilibrium ionization (NEI), radiative cooling and thermal conduction. These models are to be applied to high velocity clouds in our galactic halo that are seen to have O VI by FUSE (Sembach et ai. 2000) and other clouds for which sufficient constraining observations exist.

  11. A Numerical Study on Using Air Cooler Heat Exchanger for Low Grade Energy Recovery from Exhaust Flue Gas in Natural Gas Pressure Reduction Stations

    OpenAIRE

    Mansoor Naderi; Ghasem Zargar; Ebrahim Khalili

    2018-01-01

    Heat EXchangers (HEX) that are used in City Gate Station (CGS) systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the cooling fluid. Then, the effects of sizes and numbers of fins and tube rows on recovered heat rate were in...

  12. Comparison of alternative flue gas dry treatment technologies in waste-to-energy processes.

    Science.gov (United States)

    Dal Pozzo, Alessandro; Antonioni, Giacomo; Guglielmi, Daniele; Stramigioli, Carlo; Cozzani, Valerio

    2016-05-01

    Acid gases such as HCl and SO2 are harmful both for human health and ecosystem integrity, hence their removal is a key step of the flue gas treatment of Waste-to-Energy (WtE) plants. Methods based on the injection of dry sorbents are among the Best Available Techniques for acid gas removal. In particular, systems based on double reaction and filtration stages represent nowadays an effective technology for emission control. The aim of the present study is the simulation of a reference two-stage (2S) dry treatment system performance and its comparison to three benchmarking alternatives based on single stage sodium bicarbonate injection. A modelling procedure was applied in order to identify the optimal operating configuration of the 2S system for different reference waste compositions, and to determine the total annual cost of operation. Taking into account both operating and capital costs, the 2S system appears the most cost-effective solution for medium to high chlorine content wastes. A Monte Carlo sensitivity analysis was carried out to assess the robustness of the results. Copyright © 2016. Published by Elsevier Ltd.

  13. Optimized CO2-flue gas separation model for a coal fired power plant

    Energy Technology Data Exchange (ETDEWEB)

    Arachchige, Udara S.P.R. [Telemark University College, Porsgrunn (Norway); Mohsin, Muhammad [Telemark University College, Porsgrunn (Norway); Melaaen, Morten C. [Telemark University College, Porsgrunn (Norway); Tel-Tek, Porsgrunn (Norway)

    2013-07-01

    The detailed description of the CO2 removal process using mono-ethylamine (MEA) as a solvent for coal-fired power plant is present in this paper. The rate based Electrolyte NRTL activity coefficient model was used in the Aspen Plus. The complete removal process with re-circulating solvent back to the absorber was implemented with the sequential modular method in Aspen Plus. The most significant cost related to CO2 capture is the energy requirement for re-generating solvent, i.e. re-boiler duty. Parameters’ effects on re-boiler duty were studied, resulting decreased re-boiler duty with the packing height and absorber packing diameter, absorber pressure, solvent temperature, stripper packing height and diameter. On the other hand, with the flue gas temperature, re-boiler duty is increased. The temperature profiles and CO2 loading profiles were used to check the model behavior.

  14. Bench-Scale Demonstration of Hot-Gas Desulfurization Technology

    International Nuclear Information System (INIS)

    Portzer, Jeffrey W.; Gangwal, Santosh K.

    1997-01-01

    Prior to the current project, development of the DSRP was done in a laboratory setting, using synthetic gas mixtures to simulate the regeneration off-gas and coal gas feeds. The objective of the current work is to further the development of zinc titanate fluidized-bed desulfurization (ZTFBD) and the DSRP for hot-gas cleanup by testing with actual coal gas. The objectives of this project are to: (1) Develop and test an integrated, skid-mounted, bench-scale ZTFBD/DSRP reactor system with a slipstream of actual coal gas; (2) Test the bench-scale DSRP over an extended period with a slipstream of actual coal gas to quantify the degradation in performance, if any, caused by the trace contaminants present in coal gas (including heavy metals, chlorides, fluorides, and ammonia); (3) Expose the DSRP catalyst to actual coal gas for extended periods and then test its activity in a laboratory reactor to quantify the degradation in performance, if any, caused by static exposure to the trace contaminants in coal gas; (4) Design and fabricate a six-fold larger-scale DSRP reactor system for future slipstream testing; (5) Further develop the fluidized-bed DSRP to handle high concentrations (up to 14 percent) of SO 2 that are likely to be encountered when pure air is used for regeneration of desulfurization sorbents; and (6) Conduct extended field testing of the 6X DSRP reactor with actual coal gas and high concentrations of SO 2 . The accomplishment of the first three objectives--testing the DSRP with actual coal gas, integration with hot-gas desulfurization, and catalyst exposure testing--was described previously (Portzer and Gangwal, 1994, 1995; Portzer et al., 1996). This paper summarizes the results of previous work and describes the current activities and plans to accomplish the remaining objectives

  15. Regenerable sorbents for mercury capture in simulated coal combustion flue gas.

    Science.gov (United States)

    Rodríguez-Pérez, Jorge; López-Antón, M Antonia; Díaz-Somoano, Mercedes; García, Roberto; Martínez-Tarazona, M Rosa

    2013-09-15

    This work demonstrates that regenerable sorbents containing nano-particles of gold dispersed on an activated carbon are efficient and long-life materials for capturing mercury species from coal combustion flue gases. These sorbents can be used in such a way that the high investment entailed in their preparation will be compensated for by the recovery of all valuable materials. The characteristics of the support and dispersion of gold in the carbon surface influence the efficiency and lifetime of the sorbents. The main factor that determines the retention of mercury and the regeneration of the sorbent is the presence of reactive gases that enhance mercury retention capacity. The capture of mercury is a consequence of two mechanisms: (i) the retention of elemental mercury by amalgamation with gold and (ii) the retention of oxidized mercury on the activated carbon support. These sorbents were specifically designed for retaining the mercury remaining in gas phase after the desulfurization units in coal power plants. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Field measurements of flue gases from combustion of miscellaneous fuels using a low-resolution FTIR gas analyzer

    International Nuclear Information System (INIS)

    Larjava, K.T.; Tormonen, K.E.; Jaakkola, P.T.; Roos, A.A.

    1997-01-01

    Combustion flue gases of three different industrial boilers firing miscellaneous fuels (peat, wood, and bark, sawdust and biological sludge) were monitored for a two-week period. Nitric oxide (NO), sulfur dioxide (SO 2 ), carbon monoxide (CO), carbon dioxide (CO 2 ), and total hydrocarbons (C x H y ) were continuously measured using single-component gas analyzers in parallel with a low-resolution Fourier Transform Infrared (FTIR) gas analyzer. Hydrogen chloride (HCl) was measured continuously using the FTIR analyzer and semi-continuously using a traditional liquid-absorption technique. Nitrous oxide (N 2 O), nitrogen dioxide (NO 2 ), and water vapor (H 2 O) were continuously measured using the FTIR analyzer only. Laboratory tests were conducted prior to the field measurements to assess the detection limits of the different measurement methods for each gas component. No significant differences were found between the results of the low-resolution FTIR analyzer and the single-component analyzers or the liquid absorption method. 11 refs., 10 figs., 3 tabs

  17. Heat and mass transfer in a vertical flue ring furnace

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, Mona

    1997-12-31

    The main emphasis of this thesis was the design of a mathematical simulation model for studying details in the baking of anodes in the Hydro Aluminium anode baking furnace. The change of thermal conductivity, density, porosity and permeability during heat treatment was investigated. The Transient Plane Source technique for measuring thermal conductivity of solids was used on green carbon materials during the baking process in the temperature range 20-600 {sup o}C. Next, change of mass, density, porosity and permeability of anode samples were measured after being baked to temperatures between 300 and 1200 {sup o}C. The experimental data were used for parameter estimation and verification of property models for use in the anode baking models. Two distinct mathematical models have been modified to study the anode baking. A transient one-dimensional model for studying temperature, pressure and gas evolution in porous anodes during baking was developed. This was extended to a two-dimensional model incorporating the flue gas flow. The mathematical model which included porous heat and mass transfer, pitch pyrolysis, combustion of volatiles, radiation and turbulent channel flow, was developed by source code modification of the Computational Fluid Dynamics code FLUENT. The two-dimensional geometry of a flue gas channel adjacent to a porous flue gas wall, packing coke and anode was used for studying the effect of different firing strategies, raw materials properties and packing coke thickness. The model proved useful for studying the effects of heating rate, geometry and anode properties. 152 refs., 73 figs, 11 tabs.

  18. Sulfur transformations related to revegetation of flue gas desulfurization sludge disposal sites

    Energy Technology Data Exchange (ETDEWEB)

    Barlas, S.A.; Artiola, J.F.; Salo, L.F.; Goodrich-Mahoney, J.W. [University of Arizona, Tucson, AZ (United States). Dept. of Soil, Water and Environmental Sciences

    1999-10-01

    This study investigated factors controlling redox conditions in flue gas desulfurization (FGD) sludge and identified ways to minimize the production of phytotoxic reduced sulfur species at FGD sludge disposal sites. The oxidation of reduced FGD sludge (Eh-385 mV) appears to be a two-step process mostly controlled by water content. Eighty percent of total sulfide in reduced sludge was oxidized within 20 h of exposure to air with constant water evaporation. When organic carbon (OC) was added to saturated oxidized sludge, the Eh dropped exponentially. Sulfate reduction began at an Eh of about -75 mV and reached a maximum at -265 to -320 mV. Water content, degree of mixing, concentration of OC, and temperature control the rate and extent of reduction of FGD sludge. This suggests that water saturation and OC inputs to revegetated disposal sites should be controlled, especially during warm temperatures, to prevent production of phytotoxic levels of sulfides.

  19. The method of determination of mercury adsorption from flue gases

    Directory of Open Access Journals (Sweden)

    Budzyń Stanisław

    2017-01-01

    Full Text Available For several recent years Faculty of Energy and Fuels of the AGH University of Science and Technology in Krakow conduct intensive studies on the occurrence of mercury contained in thermal and coking coals, as well as on the possible reduction of fossil-fuel mercury emissions. This research focuses, among others, on application of sorbents for removal of mercury from flue gases. In this paper we present the methodology for testing mercury adsorption using various types of sorbents, in laboratory conditions. Our model assumes burning a coal sample, with a specific mercury content, in a strictly determined time period and temperature conditions, oxygen or air flow rates, and the flow of flue gases through sorbent in a specific temperature. It was developed for particular projects concerning the possibilities of applying different sorbents to remove mercury from flue gases. Test stand itself is composed of a vertical pipe furnace inside which a quartz tube was mounted for sample burning purposes. At the furnace outlet, there is a heated glass vessel with a sorbent sample through which flue gases are passing. Furnace allows burning at a defined temperature. The exhaust gas flow path is heated to prevent condensation of the mercury vapor prior to contact with a sorbent. The sorbent container is positioned in the heating element, with controlled and stabilized temperature, which allows for testing mercury sorption in various temperatures. Determination of mercury content is determined before (coal and sorbent, as well as after the process (sorbent and ash. The mercury balance is calculated based on the Hg content determination results. This testing method allows to study sorbent efficiency, depending on sorption temperature, sorbent grain size, and flue-gas rates.

  20. Exergy analysis of a combined vapor power cycle and boiler flue gas driven double effect water–LiBr absorption refrigeration system

    International Nuclear Information System (INIS)

    Talukdar, K.; Gogoi, T.K.

    2016-01-01

    Highlights: • A combined vapor power and double effect water–LiBr absorption refrigeration system is proposed. • The flue gas of the power cycle boiler is the heat source for the double effect refrigeration system. • Energy and exergy analyses are performed to evaluate performance of the combined system. • Effect of high pressure generator temperature on combined system performance is highlighted. • Comparison is provided with a single effect absorption system integrated combined system. - Abstract: A combined vapor power cycle (PC) and double effect water–LiBr absorption refrigeration system (ARS) is proposed in this study. The boiler leaving flue gas of the PC is the heat source for the high pressure generator (HPG) of the double effect ARS. Exergy analysis of the proposed system is performed to show the performance variation of both the topping PC and the bottoming ARS with changing HPG temperature from 120 °C to 150 °C. Further the performance of double effect ARS integrated combined power and cooling system is compared with a similar system integrated with a single effect ARS. HPG temperature of the double effect ARS and generator temperature of the single effect ARS are considered as 120 °C and 80 °C respectively. Results show that the power and efficiency of the topping PC decreases with HPG temperature due to reduction in steam generation rate in the boiler. COP and exergy efficiency of the double effect ARS also reduces with increasing HPG temperature. The irreversible losses in the PC components decrease while the total irreversibility of the combined power and cooling system increases with HPG temperature due to increase in exergy loss with the HPG leaving flue gas and irreversibility of the ARS components. PC performance does not vary much due to replacement of the double effect ARS with the single effect ARS, however higher COP and exergy efficiency of the double effect system are achieved with much lower irreversible losses in the

  1. Method of removing hydrogen sulphide from hot gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Furimsky, E.; Yumura, M.

    1987-12-22

    Hydrogen sulphide can be removed from hot gas mixtures by contacting the hot gas mixture at temperatures in the range of 500-900/sup 0/C with an adsorbent consisting of managanese nodules. The nodules may contain additional calcium cations. In sulphided form, the nodules are catalytically active for hydrogen sulphide decomposition to produce hydrogen. Regeneration of the adsorbent can be accomplished by roasting in an oxidizing atmosphere. The nodules can be used to treat gaseous mixtures containing up to 20% hydrogen sulfide, for example, gases produced during pyrolysis, cracking, coking, and hydrotreating processes. Experiments using the processes described in this patent are also outlined. 6 tabs.

  2. HOT GAS HALOS AROUND DISK GALAXIES: CONFRONTING COSMOLOGICAL SIMULATIONS WITH OBSERVATIONS

    International Nuclear Information System (INIS)

    Rasmussen, Jesper; Sommer-Larsen, Jesper; Pedersen, Kristian; Toft, Sune; Grove, Lisbeth F.; Benson, Andrew; Bower, Richard G.

    2009-01-01

    Models of disk galaxy formation commonly predict the existence of an extended reservoir of accreted hot gas surrounding massive spirals at low redshift. As a test of these models, we use X-ray and Hα data of the two massive, quiescent edge-on spirals NGC 5746 and NGC 5170 to investigate the amount and origin of any hot gas in their halos. Contrary to our earlier claim, the Chandra analysis of NGC 5746, employing more recent calibration data, does not reveal any significant evidence for diffuse X-ray emission outside the optical disk, with a 3σ upper limit to the halo X-ray luminosity of 4 x 10 39 erg s -1 . An identical study of the less massive NGC 5170 also fails to detect any extraplanar X-ray emission. By extracting hot halo properties of disk galaxies formed in cosmological hydrodynamical simulations, we compare these results to expectations for cosmological accretion of hot gas by spirals. For Milky-Way-sized galaxies, these high-resolution simulations predict hot halo X-ray luminosities which are lower by a factor of ∼2 compared to our earlier results reported by Toft et al. We find the new simulation predictions to be consistent with our observational constraints for both NGC 5746 and NGC 5170, while also confirming that the hot gas detected so far around more actively star-forming spirals is in general probably associated with stellar activity in the disk. Observational results on quiescent disk galaxies at the high-mass end are nevertheless providing powerful constraints on theoretical predictions, and hence on the assumed input physics in numerical studies of disk galaxy formation and evolution.

  3. Catalytic Activity and Deactivation of SO2 Oxidation Catalysts in Simulated Power Plant Flue Gases

    DEFF Research Database (Denmark)

    Masters, Stephen G.; Chrissanthopoulos, Asthanassios; Eriksen, Kim Michael

    1997-01-01

    The catalyst deactivation and the simultaneious formation of compounds in commercial SO2 oxidation catalysts have been studied by combined activity measurements and in situ EPR spectroscopy in the temperature range 350-480 C in wet and dry simulated power plant flue gas.......The catalyst deactivation and the simultaneious formation of compounds in commercial SO2 oxidation catalysts have been studied by combined activity measurements and in situ EPR spectroscopy in the temperature range 350-480 C in wet and dry simulated power plant flue gas....

  4. Rheinbraun`s experience in hot gas cleaning

    Energy Technology Data Exchange (ETDEWEB)

    Renzenbrink, W.; Wischnewski, R. [Rheinbraun AG, Koeln (Germany)

    1998-11-01

    For the introduction of modern types of power stations like IGCC, PCFBC, etc. the application of a functional hot gas filter is of essential importance. A hot gas filter with two tiers for dry and complete dedusting of the entire raw gas flow of 53,000 m{sup 3}(STP)/h was started up in 1993 in the High Temperature Winkler (HTW) coal gasification demonstration plant in Hurth/Berrenrath near Cologne, Germany. The operational data of the filter are a pressure of 10 bar and a temperature of 270{degree}C. The filter was supplied by the `LLB` company and is characterised by the principle of upright arrangement of the ceramic filter elements. During nearly 8,000 h of plant operation up to September 1995 the filter showed stable and safe operation, a separation efficiency of {gt}99.98%, a 21% reduction in filtration surface, reduction in cleaning gas requirement by factor 10, reduction in cleaning gas pressure to 16 bar and a significant reduction in maintenance and operating costs. The resultant clean gas dust content was {lt} 3 mg/m{sup 3}(STP) compared to the design value of 5 mg/m{sup 3}(STP). In a test to the limit of operation one failure occurred when 20 candles broke. In order to yield larger filtering surfaces in very large filter units, e.g. for IGCCs, without using more than one filter the multistage design is the only sensible solution. Prior to industrial-scale application such a system has to be tested. Therefore the two-tier filter was converted into a three-tier type with separate filter modules at the end of 1995. After another 5,400 h of plant operation this three-tier filter shows safe and stable operation with a clean gas dust content of {lt} 2 mg/m{sup 3}(STP). 3 refs., 5 figs., 1 tab.

  5. Potential for preparation of hot gas cleanup sorbents from spent hydroprocessing catalysts

    Energy Technology Data Exchange (ETDEWEB)

    Furimsky, E.; Biagini, M. [Canada Centre for Mineral and Energy Technology, Ottawa, ON (Canada). Energy Research Labs.

    1996-01-01

    Three spent-decoked hydroprocessing catalysts and two corresponding fresh catalysts were tested as hot gas clean-up sorbents and compared with the zinc ferrite using a simulated coal gasification gas mixture. The catalysts deposited only by coke exhibited relatively good cleaning efficiency. The catalyst deposited by coke and metals such as vanadium and nickel was less efficient. The useful life of the spent hydroprocessing catalysts may be extended if utilized as hot gas clean-up sorbents. 12 refs., 3 figs., 4 tabs.

  6. Cosmic X-ray background from hot gas

    International Nuclear Information System (INIS)

    Rogers, R.D.; Field, G.B.

    1991-01-01

    This paper considers constraints on models of the cosmic X-ray background (XRB) in which the XRB is produced by optically thin thermal bremsstrahlung from hot gas. It is shown that models in which the gas is gravitationally confined in a spherical configuration and is heated only once are contradicted by the observed number of gravitationally lensed quasars together with the lower limit on the number of XRB sources required by limits on fluctuations in the XRB and the cosmic microwave background. In addition, it is shown that, for models in which the gas is not gravitationally confined, the expansion time of the gas is much shorter than the radiative cooling time, so that such models cannot explain the XRB. It is concluded that thermal bremsstrahlung models cannot account for the XRB if the emitting gas is heated only once. 31 refs

  7. Desain Pabrik Sodium Karbonat Dari CO2 Flue Gas Pabrik Semen

    Directory of Open Access Journals (Sweden)

    Muhammad Fadlan Minallah

    2017-03-01

    Full Text Available Dengan semakin meningkatnya kebutuhan energi di Indonesia selama beberapa tahunn terakhir ini, semakin juga meningkatkan bertambahnya gas rumah kaca yang dihasilkan. Gas rumah kaca (GRK yang terdiri dari CO2, CH4, N2O, HCFC, dan CFC serta uap air (H2O, dimana yang menjadi sumber utama terjadinya pemasan global. Terutama pada pabrik yang menghasilkan GRK itu sendiri selama proses produksi, seperti pabrik semen 15.107.267 ton, pabrik produksi kapur 3.688.147 ton, dan pabrik kaca/gelas 170.000 ton. Prospek soda abu (nama pasar sodium karbonat di Indonesia masih dalam kondisi baik karena kebutuhan komoditas ini semakin bertambah dengan rate 3,4% pertahun untuk industri kapur, industri gelas, dan industri keramik. Selama ini kebutuhan soda abu di Indonesia masih dipenuhi dengan adanya impor dari negara lain, karena belum adanya produsen natrium karbonat di dalam negeri yang menjadikan komoditas ini sebagai produk utama dari pabriknya. Pabrik ini direncanakan akan didirikan di Kabupaten Tuban, JawaTimur dengan estimasi waktu mulai produksi pada tahun 2017. Penentuan lokasi pabrik berdasarkan pada sumber bahan baku. Hal ini karena bahan baku yang digunakan adalah flue gas dari pabrik semen. Untuk menemuhi kebutuhan akan sodium karbonat kapasitas produk sodium karbonat ini sebesar 86,37 ton/jam. Pabrik beroperasi selama 24 jam per hari dengan hari kerja 330 hari per tahun. Proses pembuatan soda abu dengan proses karbonasi terdiri dari empat unit proses, yaitu dust removal unit, absorption unit, crystalization unit, dan soda ash unit. Dari analisa perhitungan ekonomi didapat Investasi Rp79.285.526.850, IRR sebesar 26%, POT selama 4,39 tahun, dan NPV positif 15 tahun sebesar Rp589.068.911.634. Umur dari pabrik ini diperkirakan selama 15 tahun dengan masa periode pembangunannya selama 2 tahun di mana operasi pabrik ini 330 hari/tahun.

  8. Method and device for incinerating radioactive wastes and preparing burnable wastes for non-polluting storage

    International Nuclear Information System (INIS)

    Hempelmann, W.

    1975-01-01

    An apparatus for incinerating radioactive wastes includes a furnace which has air inlet conduits and a flue gas outlet conduit and air heaters as well as blowers connected to the air inlets for forcing hot air into the furnace. The apparatus further has a feeding device connected to the charging end of the furnace for introducing liquid or solid wastes thereinto and a device which communicates with the discharge end of the furnace for removing solid reaction products from the furnace. In the flue gas conduit there is connected a plurality of flue gas filters each containing filter candles, a flue gas chamber and a mechanism for removing ashes from the flue gas chamber. The apparatus also includes a mixer section connected with the outlet of each flue gas filter and having a mechanism for mixing cool air with the flue gas filtered by the flue gas filters. Gas blowers connected to the output of the mixer section draw the gas from the apparatus. 18 Claims, 8 Drawing Figures

  9. Non-catalytic recuperative reformer

    Science.gov (United States)

    Khinkis, Mark J.; Kozlov, Aleksandr P.; Kurek, Harry

    2015-12-22

    A non-catalytic recuperative reformer has a flue gas flow path for conducting hot flue gas from a thermal process and a reforming mixture flow path for conducting a reforming mixture. At least a portion of the reforming mixture flow path is embedded in the flue gas flow path to permit heat transfer from the hot flue gas to the reforming mixture. The reforming mixture flow path contains substantially no material commonly used as a catalyst for reforming hydrocarbon fuel (e.g., nickel oxide, platinum group elements or rhenium), but instead the reforming mixture is reformed into a higher calorific fuel via reactions due to the heat transfer and residence time. In a preferred embodiment, extended surfaces of metal material such as stainless steel or metal alloy that are high in nickel content are included within at least a portion of the reforming mixture flow path.

  10. Economic assessment of advanced flue gas desulfurization processes. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bierman, G. R.; May, E. H.; Mirabelli, R. E.; Pow, C. N.; Scardino, C.; Wan, E. I.

    1981-09-01

    This report presents the results of a project sponsored by the Morgantown Energy Technology Center (METC). The purpose of the study was to perform an economic and market assessment of advanced flue gas desulfurization (FGD) processes for application to coal-fired electric utility plants. The time period considered in the study is 1981 through 1990, and costs are reported in 1980 dollars. The task was divided into the following four subtasks: (1) determine the factors affecting FGD cost evaluations; (2) select FGD processes to be cost-analyzed; (3) define the future electric utility FGD system market; and (4) perform cost analyses for the selected FGD processes. The study was initiated in September 1979, and separate reports were prepared for the first two subtasks. The results of the latter two subtasks appear only in this final reprot, since the end-date of those subtasks coincided with the end-date of the overall task. The Subtask 1 report, Criteria and Methods for Performing FGD Cost Evaluations, was completed in October 1980. A slightly modified and condensed version of that report appears as appendix B to this report. The Subtask 2 report, FGD Candidate Process Selection, was completed in January 1981, and the principal outputs of that subtask appear in Appendices C and D to this report.

  11. A Diaminopropane-Appended Metal–Organic Framework Enabling Efficient CO 2 Capture from Coal Flue Gas via a Mixed Adsorption Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Milner, Phillip J.; Siegelman, Rebecca L.; Forse, Alexander C.; Gonzalez, Miguel I.; Runčevski, Tomče [Materials; Martell, Jeffrey D.; Reimer, Jeffrey A.; Long, Jeffrey R. [Materials

    2017-09-14

    A new diamine-functionalized metal–organic framework comprised of 2,2-dimethyl-1,3-diaminopropane (dmpn) appended to the Mg2+ sites lining the channels of Mg2(dobpdc) (dobpdc4– = 4,4'-dioxidobiphenyl-3,3'-dicarboxylate) is characterized for the removal of CO2 from the flue gas emissions of coal-fired power plants. Unique to members of this promising class of adsorbents, dmpn–Mg2(dobpdc) displays facile step-shaped adsorption of CO2 from coal flue gas at 40 °C and near complete CO2 desorption upon heating to 100 °C, enabling a high CO2 working capacity (2.42 mmol/g, 9.1 wt %) with a modest 60 °C temperature swing. Evaluation of the thermodynamic parameters of adsorption for dmpn–Mg2(dobpdc) suggests that the narrow temperature swing of its CO2 adsorption steps is due to the high magnitude of its differential enthalpy of adsorption (Δhads = -73 ± 1 kJ/mol), with a larger than expected entropic penalty for CO2 adsorption (Δsads = -204 ± 4 J/mol·K) positioning the step in the optimal range for carbon capture from coal flue gas. In addition, thermogravimetric analysis and breakthrough experiments indicate that, in contrast to many adsorbents, dmpn–Mg2(dobpdc) captures CO2 effectively in the presence of water and can be subjected to 1000 humid adsorption/desorption cycles with minimal degradation. Solid-state 13C NMR spectra and single-crystal X-ray diffraction structures of the Zn analogue reveal that this material adsorbs CO2 via formation of both ammonium carbamates and carbamic acid pairs, the latter of which are crystallographically verified for the first time in a porous material. Taken together, these properties render dmpn–Mg2(dobpdc) one of the most promising adsorbents for carbon capture applications.

  12. Advanced Flue Gas Desulfurization (AFGD) demonstration project: Volume 2, Project performance and economics. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-30

    The project objective is to demonstrate removal of 90--95% or more of the SO{sub 2} at approximately one-half the cost of conventional scrubbing technology; and to demonstrate significant reduction of space requirements. In this project, Pure Air has built a single SO{sub 2} absorber for a 528-MWe power plant. The absorber performs three functions in a single vessel: prequencher, absorber, and oxidation of sludge to gypsum. Additionally, the absorber is of a co- current design, in which the flue gas and scrubbing slurry move in the same direction and at a relatively high velocity compared to conventional scrubbers. These features all combine to yield a state- of-the-art SO{sub 2} absorber that is more compact and less expensive than conventional scrubbers. The project incorporated a number of technical features including the injection of pulverized limestone directly into the absorber, a device called an air rotary sparger located within the base of the absorber, and a novel wastewater evaporation system. The air rotary sparger combines the functions of agitation and air distribution into one piece of equipment to facilitate the oxidation of calcium sulfite to gypsum. Additionally, wastewater treatment is being demonstrated to minimize water disposal problems inherent in many high-chloride coals. Bituminous coals primarily from the Indiana, Illinois coal basin containing 2--4.5% sulfur were tested during the demonstration. The Advanced Flue Gas Desulfurization (AFGD) process has demonstrated removal of 95% or more of the SO{sub 2} while providing a commercial gypsum by-product in lieu of solid waste. A portion of the commercial gypsum is being agglomerated into a product known as PowerChip{reg_sign} gypsum which exhibits improved physical properties, easier flowability and more user friendly handling characteristics to enhance its transportation and marketability to gypsum end-users.

  13. Methods for the analysis of SO/sub 2/, SO/sub 3/ and H/sub 2/S in flue gas and the calculation of the acid dew point

    Energy Technology Data Exchange (ETDEWEB)

    Albertyn, C.H.

    1986-02-01

    Methods are given for the analysis of SO/sub 2/, SO/sub 3/, and H/sub 2/S in flue gas. Two methods are described for the determination of SO/sub 2/. The method to be used depends on whether or not H/sub 2/S is present in the gas stream. An equation for the calculation of acid dew point is given as well.

  14. Experimental Studies of CO2 Capturing from the Flue Gases

    Directory of Open Access Journals (Sweden)

    Ehsan Rahmandoost

    2014-10-01

    Full Text Available CO2 emissions from combustion flue gases have turned into a major factor in global warming. Post-combustion carbon capture (PCC from industrial utility flue gases by reactive absorption can substantially reduce the emissions of the greenhouse gas CO2. To test a new solvent (AIT600 for this purpose, a small pilot plant was used. This paper presents the results of studies on chemical methods of absorbing CO2 from flue gases with the new solvent, and evaluates the effects of operating conditions on CO2 absorption efficiency. CO2 removal rate of the AIT600 solvent was higher in comparison to the conventional monoethanolamine (MEA solvent. The optimized temperature of the absorber column was 60 °C for CO2 absorption in this pilot plant. The overall absorption rate (Φ and the volumetric overall mass transfer coefficient (KGaV were also investigated.

  15. Effect of flue gas recirculation during oxy-fuel combustion in a rotary cement kiln

    International Nuclear Information System (INIS)

    Granados, David A.; Chejne, Farid; Mejía, Juan M.; Gómez, Carlos A.; Berrío, Ariel; Jurado, William J.

    2014-01-01

    The effect of Flue Gas Recirculation (FGR) during Oxy-Fuel Combustion in a Rotary Cement Kiln was analyzed by using a CFD model applied to coal combustion process. The CFD model is based on 3D-balance equations for mass, species, energy and momentum. Turbulence and radiation model coupled to a chemical kinetic mechanism for pyrolysis processes, gas–solid and gas–gas reactions was included to predicts species and flame temperature distribution, as well as convective and radiation energy fluxes. The model was used to study coal combustion with air and with oxygen for FGR between 30 and 85% as controller parameter for temperature in the process. Flame length effect and heat transfer by convection and radiation to the clinkering process for several recirculation ratios was studied. Theoretical studies predicted a located increase of energy flux and a reduction in flame length with respect to the traditional system which is based on air combustion. The impact of FGR on the oxy-fuel combustion process and different energy scenarios in cement kilns to increase energy efficiency and clinker production were studied and evaluated. Simulation results were in close agreement with experimental data, where the maximum deviation was 7%

  16. Pilot-scale test for electron beam purification of flue gas from coal-combustion boiler

    International Nuclear Information System (INIS)

    Namba, Hideki; Tokunaga, Okihiro; Hashimoto, Shoji; Doi, Yoshitaka; Aoki, Shinji; Izutsu, Masahiro

    1995-01-01

    A pilot-scale test for electron beam treatment of flue gas (12,000m 3 N/hr) from coal-fired boiler was conducted by Japan Atomic Energy Research Institute, Chubu Electric Power Company and Ebara Corporation, in the site of Shin-Nagoya Thermal Power Plant in Nagoya, Japan. During 14 months operation, it was proved that the method is possible to remove SO 2 and NO x simultaneously in wide concentration range of SO 2 (250-2,000ppm) and NO x (140-240ppm) with higher efficiency than the conventional methods, with appropriate operation conditions (dose, temperature etc.). The pilot plant was easily operated with well controllability and durability, and was operated for long period of time without serious problems. The byproduct, ammonium sulfate and ammonium nitrate, produced by the treatment was proved to be a nitrogenous fertilizer with excellent quality. (author)

  17. Advanced Flue Gas Desulfurization (AFGD) Demonstration Project, A DOE Assessment; FINAL

    International Nuclear Information System (INIS)

    National Energy Technology Laboratory

    2001-01-01

    The AFGD process as demonstrated by Pure Air at the Bailly Station offers a reliable and cost-effective means of achieving a high degree of SO(sub 2) emissions reduction when burning high-sulfur coals. Many innovative features have been successfully incorporated in this process, and it is ready for widespread commercial use. The system uses a single-loop cocurrent scrubbing process with in-situ oxidation to produce wallboard-grade gypsum instead of wet sludge. A novel wastewater evaporation system minimizes effluents. The advanced scrubbing process uses a common absorber to serve multiple boilers, thereby saving on capital through economies of scale. Major results of the project are: (1) SO(sub 2) removal of over 94 percent was achieved over the three-year demonstration period, with a system availability exceeding 99.5 percent; (2) a large, single absorber handled the combined flue gas of boilers generating 528 MWe of power, and no spares were required; (3) direct injection of pulverized limestone into the absorber was successful; (4) Wastewater evaporation eliminated the need for liquid waste disposal; and (5) the gypsum by-product was used directly for wallboard manufacture, eliminating the need to dispose of waste sludge

  18. Simultaneous absorption of SO2 and NO from flue gas with KMnO4/NaOH solutions

    International Nuclear Information System (INIS)

    Chu, H.; Chien, T.W.; Li, S.Y.

    2001-01-01

    The wet scrubbing combined SO x /NO x removal system is an advanced air pollution control device. This study attempts to understand the absorption kinetics in the system. The absorption of diluted SO 2 and simultaneous absorption of diluted SO 2 and NO, as occurs in flue gases, in a stirred tank reactor with KMnO 4 /NaOH solutions were carried out at 50C. The liquid-side and gas-side mass transfer coefficients of the system were determined. The results indicate that the absorption of SO 2 is close to completely gas-film controlled where the NaOH concentration is greater than 0.1 M or the KMnO 4 concentration is greater than 0.05 M. The increasing gas flow rate has a positive effect on the absorption rate of SO 2 . The existence of O 2 has no significant effect on the absorption rate of SO 2 . Adding SO 2 would decrease the absorption rate of NO; however, the addition of NO has no effect on the absorption rate of SO 2

  19. Corrosivity of hot flue gases in the fluidized bed combustion of recovered waste wood

    Energy Technology Data Exchange (ETDEWEB)

    Enestam, S.

    2011-07-01

    In recent years, recovered waste wood has become a fuel of interest due to its green energy benefits and low price compared to virgin wood-based fuels. However, waste wood is often contaminated with paint, plastic, and metal components, producing concentrations of heavy metals such as zinc and lead, chlorine, sodium, and sometimes sulphur that are elevated relative to those in virgin wood. In several cases, boilers burning waste wood have experienced increased fouling and corrosion of furnace walls, superheaters, and economizers, problems associated with chlorine, zinc, lead, and alkali metals in the deposits. The location of the deposits and the corrosion as well as the composition of the deposits vary with the fuel composition, boiler design, combustion parameters, flue gas temperature, and material temperature. Experience gained from the operation of biofuel and waste boilers shows that corrosion damage can be reduced, or even avoided, by the selection of optimum materials or for heat exchanger surfaces, by the use of fuel mixtures or additives that decrease the corrosivity of the combustion environment, by the placement of superheaters in a less corrosive environment, and by adjusting the steam parameters. Finding the right solutions for boilers burning RWW requires a thorough understanding of the whole process, including the fuel fed into the boiler, the combustion atmosphere, the corrosivity of the flue gas and the deposits, and the corrosion resistance of different boiler materials under the prevailing conditions. The objective of this work was to shed more light on the combustion environment in bubbling fluidized bed boilers burning RWW and thus increase knowledge about the corrosivity of zinc- and lead-rich deposits formed during the combustion of RWW, with the final goal of developing a corrosion prediction tool for use in the design of boilers for RWW combustion. With such a tool, it would be possible to optimize boiler design and material selection with

  20. Improved biomass and lipid production in a mixotrophic culture of Chlorella sp. KR-1 with addition of coal-fired flue-gas.

    Science.gov (United States)

    Praveenkumar, Ramasamy; Kim, Bohwa; Choi, Eunji; Lee, Kyubock; Park, Ji-Yeon; Lee, Jin-Suk; Lee, Young-Chul; Oh, You-Kwan

    2014-11-01

    Industrial CO2-rich flue-gases, owing to their eco-toxicity, have yet to be practically exploited for microalgal biomass and lipid production. In this study, various autotrophic and mixotrophic culture modes for an oleaginous microalga, Chlorella sp. KR-1 were compared for the use in actual coal-fired flue-gas. Among the mixotrophic conditions tested, the fed-batch feedings of glucose and the supply of air in dark cycles showed the highest biomass (561 mg/L d) and fatty-acid methyl-ester (168 mg/L d) productivities. This growth condition also resulted in the maximal population of microalgae and the minimal population and types of KR-1-associated-bacterial species as confirmed by particle-volume-distribution and denaturing-gradient-gel-electrophoresis (DGGE) analyses. Furthermore, microalgal lipid produced was assessed, based on its fatty acid profile, to meet key biodiesel standards such as saponification, iodine, and cetane numbers. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Amelioration of alkali soil using flue gas desulfurization byproducts: productivity and environmental quality

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.J.; Chen, C.H.; Xu, X.C.; Li, Y.J. [Tsing Hua University, Beijing (China). Ministry of Education

    2008-01-15

    In this study, flue gas desulfurization (FGD) byproducts are used to ameliorate alkali soil. The average application rates for soils with low exchangeable sodium percentage (ESP), mid ESP, and high ESP are 20.9, 30.6, and 59.3 Mg ha{sup -1} respectively. The experimental results obtained for 3 consecutive years reveal that the emergence ratios and yields of the crops were 1.1-7.6 times and 1.1-13.9 times those of the untreated control, respectively. The concentrations of Cr, Pb, Cd, As, and Hg in the treated soils are far below the background values stipulated by the Environmental Quality Standard for Soils (GB 15618-1995). Their concentrations in the seeds of corn and alfalfa grown in the treated soils are far below the tolerance limits regulated by National Food Standards of China. The results of this research demonstrate that the amelioration of alkali soils using FGD byproducts is promising.

  2. LIFAC flue gas desulfurization process an alternative SO{sub 2} control strategy

    Energy Technology Data Exchange (ETDEWEB)

    Patel, J.G. [Tampella Power Corp., Atlanta, GA (United States); Vilala, J. [Tampella Power Inc., Tampere (Finland)

    1995-12-01

    This paper discusses the results from two recently completed LIFAC flue gas desulfurization plants - 300 MW Shand lignite powered station owned by Saskatchewan Power Corporation and 60 MW Whitewater Valley high sulfur coal fired station owned by Richmond Powerand Light. LIFACis a dry FGD process in which limestone is injected into the upper regions of the boiler furnace and an activation reactor is used to humidify the unreacted limestone to achieve additional sulfur capture. The performance in both plants indicates that 70 to 80% sulfur is removed at a Ca/S ratio of 2. Cost performance data from these plants has shown that LI FAC both on construction cost and $/ton SO{sub 2} removed basis is very cost competitive compared to other SO{sub 2} control technologies. The Richmond plant has been realized under the auspices of the U.S. Department of Energy`s Clean Coal Technology program. The Shand plant is the first commercial installation in North America. The paper also discusses highlights of operating and maintenance experience, availability and handling of the solid waste product.

  3. A Green Desulfurization Technique: Utilization of Flue Gas SO2 to Produce H2 via a Photoelectrochemical Process Based on Mo-Doped BiVO4

    Directory of Open Access Journals (Sweden)

    Jin Han

    2017-12-01

    Full Text Available A green photoelectrochemical (PEC process with simultaneous SO2 removal and H2 production has attracted an increasing attention. The proposed process uses flue gas SO2 to improve H2 production. The improvement of the efficiency of this process is necessary before it can become industrial viable. Herein, we reported a Mo modified BiVO4 photocatalysts for a simultaneous SO2 removal and H2 production. And the PEC performance could be significantly improved with doping and flue gas removal. The evolution rate of H2 and removal of SO2 could be enhanced by almost three times after Mo doping as compared with pristine BiVO4. The enhanced H2 production and SO2 removal is attributed to the improved bulk charge carrier transportation after Mo doping, and greatly enhanced oxidation reaction kinetics on the photoanode due to the formation of SO32− after SO2 absorption by the electrolyte. Due to the utilization of SO2 to improve the production of H2, the proposed PEC process may become a profitable desulfurization technique.

  4. A green desulfurization technique: utilization of flue gas SO2 to produce H2 via a photoelectrochemical process based on Mo-doped BiVO4

    Science.gov (United States)

    Han, Jin; Li, Kejian; Cheng, Hanyun; Zhang, Liwu

    2017-12-01

    A green photoelectrochemical (PEC) process with simultaneous SO2 removal and H2 production has attracted an increasing attention. The proposed process uses flue gas SO2 to improve H2 production. The improvement of the efficiency of this process is necessary before it can become industrial viable. Herein, we reported a Mo modified BiVO4 photocatalysts for a simultaneous SO2 removal and H2 production. And the PEC performance could be significantly improved with doping and flue gas removal. The evolution rate of H2 and removal of SO2 could be enhanced by almost 3 times after Mo doping as compared with pristine BiVO4. The enhanced H2 production and SO2 removal is attributed to the improved bulk charge carrier transportation after Mo doping, and greatly enhanced oxidation reaction kinetics on the photoanode due to the formation of SO32- after SO2 absorption by the electrolyte. Due to the utilization of SO2 to improve the production of H2, the proposed PEC process may become a profitable desulfurization technique.

  5. Influence of the technique for injection of flue gas and the configuration of the swirl burner throat on combustion of gaseous fuel and formation of nitrogen oxides in the flame

    Science.gov (United States)

    Dvoinishnikov, V. A.; Khokhlov, D. A.; Knyaz'kov, V. P.; Ershov, A. Yu.

    2017-05-01

    How the points at which the flue gas was injected into the swirl burner and the design of the burner outlet influence the formation and development of the flame in the submerged space, as well as the formation of nitrogen oxides in the combustion products, have been studied. The object under numerical investigation is the flame of the GMVI combined (oil/gas) burner swirl burner fitted with a convergent, biconical, cylindrical, or divergent throat at the burner outlet with individual supply of the air and injection of the gaseous fuel through tubing. The burners of two designs were investigated; they differ by the absence or presence of an inlet for individual injection of the flue gas. A technique for numerical simulation of the flame based on the CFD methods widely used in research of this kind underlies the study. Based on the summarized results of the numerical simulation of the processes that occur in jet flows, the specific features of the aerodynamic pattern of the flame have been established. It is shown that the flame can be conventionally divided into several sections over its length in all investigations. The lengths of each of the sections, as well as the form of the fields of axial velocity, temperatures, concentrations of the fuel, oxygen, and carbon and nitrogen oxides, are different and determined by the design features of the burner, the flow rates of the agent, and the compositions of the latter in the burner ducts as well as the configuration of the burner throat and the temperature of the environment. To what degree the burner throat configuration and the techniques for injection of the flue gas at different ambient temperatures influence the formation of nitrogen oxides has been established. It is shown that the supply of the recirculation of flue gas into the fuel injection zone enables a considerable reduction in the formation of nitrogen oxides in the flame combustion products. It has been established that the locations of the zones of

  6. Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler

    Science.gov (United States)

    Cao, Weixue; Liu, Fengguo; You, Xue-yi

    2018-01-01

    Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.

  7. Radiant non-catalytic recuperative reformer

    Energy Technology Data Exchange (ETDEWEB)

    Khinkis, Mark J.; Kozlov, Aleksandr P.

    2017-10-31

    A radiant, non-catalytic recuperative reformer has a flue gas flow path for conducting hot exhaust gas from a thermal process and a reforming mixture flow path for conducting a reforming mixture. At least a portion of the reforming mixture flow path is positioned adjacent to the flue gas flow path to permit heat transfer from the hot exhaust gas to the reforming mixture. The reforming mixture flow path contains substantially no material commonly used as a catalyst for reforming hydrocarbon fuel (e.g., nickel oxide, platinum group elements or rhenium), but instead the reforming mixture is reformed into a higher calorific fuel via reactions due to the heat transfer and residence time. In a preferred embodiment, a portion of the reforming mixture flow path is positioned outside of flue gas flow path for a relatively large residence time.

  8. Energy Requirement and Comfort of Gas- and Electric-powered Hot-water Systems

    International Nuclear Information System (INIS)

    Luedemann, B.; Schmitz, G.

    1999-01-01

    In view of the continuous reduction in the specific heating energy demand of new buildings the power demand for hot-water supply increasingly dominates the heating supply of residential buildings. Furthermore, the German energy-savings-regulation 2000 (ESVO) is intended to evaluate the techniques installed such as domestic heating or hot-water supply within an overall energetic view of the building. Planning advice for domestic heating, ventilation and hot-water systems in gas-heated, low-energy buildings has therefore been developed in a common research project of the Technical University of Hamburg Harburg (TUHH) and four energy supply companies. In this article different gas-or electricity-based hot-water systems in one family houses and multiple family houses are compared with one another with regard to the aspects of comfort and power requirements considering the user's behaviour. (author)

  9. Description of dedusting in wet flue gas scrubbers with purposeful utilization of the secondary dispersion; Detailliertere Simulation der Staubabscheidung in Nasswaeschern durch Beruecksichtigung der Sekundaerdispersion

    Energy Technology Data Exchange (ETDEWEB)

    Feldkamp, M.; Lessmann, B.; Neumann, J.; Fahlenkamp, H. [Dortmund Univ. (Germany). Lehrstuhl Umwelttechnik

    2003-07-01

    Modern wet gas scrubbers are used in the power plant technology for the flue gas desulphurisation of coal-fired plants. For this the washing liquid is sprayed by numerous nozzles. The specific arrangement of the nozzles in several levels makes it possible for the spray to penetrate mutually. The penetration and overlapping of the spray in the wet scrubber causes the effect of secondary dispersion. This effect can be used effectively to improve the efficiency of the atomisation and to improve the absorption of the pollution gases in a flue gas desulphurisation scrubber. Analyses show that the cleaning efficiency of a wet scrubber depends on the distribution and the size of the drops. (orig.) [German] Moderne Gaswaescher werden in der Kraftwerkstechnik fuer die Rauchgasentschwefelung kohlebefeuerter Anlagen eingesetzt. Hierzu wird Waschfluessigkeit mit Hilfe zahlreicher Duesen zerstaeubt. Eine gezielte Anordnung der Duesen in mehreren Spruehebenen ermoeglicht es den Sprays der Duesen, sich gegenseitig zu durchdringen. Der Effekt der Sekundaerdisperson, der beim Ueberschneiden und Durchdringen der Sprays waehrend der Zerstaeubung im Rauchgaswaescher auftritt, laesst sich wirksam zur Verbesserung des Wirkungsgrades einer Rauchgasentschwefelungsanlage nutzen. Durchgefuehrte Untersuchungen zeigen, dass die Reinigungsleistung eines nassen REA-Waeschers von der Verteilung und der Groesse der Tropfen abhaengt. (orig.)

  10. Process analysis of biofuelled heat and power plants integrated with a flue gas dryer; Processtudie av biobraensleeldade kraftvaermeverk integrerade med roekgastork

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, Kent; Steinwall, Pontus [Sycon Energikonsult AB, Malmoe (Sweden)

    2000-01-01

    In this report three different processes for combined heat and power production from biomass have been evaluated and compared. Both economical and technical questions have been investigated. The examined processes are: 1. CFB fuelled with wet biomass; 2. A boiler fuelled with pulverised biomass integrated with a traditional flue gas dryer; and 3. A boiler fuelled with pulverized biomass integrated with a flue gas dryer with a closed loop. All the processes have a district heat output of 80 MW. Calculations have been made at three different loads: 100, 70 and 40 % respectively. The performance characteristics in form of electric efficiency and fuel utilisation are very similar for the processes. To evaluate the thermodynamic differences between the processes, calculations have been made with extreme temperatures in the district heating net, 65 deg C/100 deg C. The process with a closed loop drier has a saturation temperature in the flue gas of 95 deg C. Therefore this process has a high fuel utilization even if the incoming water has a high temperature. The fuel utilization for alternatives 1 and 2 decreases almost down to the efficiency of the furnace. This shows that the temperature of the water is too high to recapture the latent heat in the flue gases. The investment costs for the processes have been estimated. Also these are very similar for the three alternatives. The cost for the process with the CFB is 412 million SEK. The boiler in alternative 2 and 3 is approximately 20 million SEK cheaper than the CFB. The decreased cost for the boiler is compensated by the cost for the dryers. The investment cost for the traditional dryer has been estimated to 20 million SEK and 30 million SEK for the closed loop dryer. The total cost for alternative 2 is then 417 million SEK and 414 million SEK for alternative 3. Operation and maintenance costs for the processes with dryer are supposed to be 1 respectively 1.5 million SEK higher than for alternative 1. The dryers may

  11. Basic research on flue gas smoke treatment by electron beam

    International Nuclear Information System (INIS)

    Namba, Hideki

    1995-01-01

    Recently, accompanying the increase of the use of fossil fuel, the environment destruction due to the sulfur oxides and nitrogen oxides contained in combustion smoke has become a serious problem. The development of flue gas smoke treatment technology by using electron beam was started in Japan, and attention has been paid worldwide as the promising dry type simultaneous desulfurizing and denitrating process. In this process, by adding ammonia to smoke, and irradiating electron beam on it, ammonium nitrate and ammonium sulfate are formed. As to the reaction mechanism of denitration and desulfurization, radical formation, radical reaction, denitration mechanism, desulfurization mechanism, the particle size distribution of the formed aerosol, the amounts of denitration and desulfurization by electron beam smoke treatment process, the improvement of the denitration efficiency by multi-stage irradiation method and the improvement of the desulfurization rate by low temperature irradiation, and the basic test toward the pilot test are explained. The basic research for putting this system to practical use was carried out jointly by Japan Atomic Energy Research Institute, Chubu Electric Power Co., Inc., and Ebara Seisakusho for standard coal burning smoke in Japan. The verifying test at the pilot plant in Shinnagoya Thermal Power Station was carried out, and it was verified that this process can be used practically for treating coal-burning smoke. (K.I.)

  12. Hot Gas Cleanup Test Facility for gasification and pressurized combustion. Quarterly report, October--December 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-02-01

    The objective of this project is to evaluate hot gas particle control technologies using coal-derived gas streams. This will entail the design, construction, installation, and use of a flexible test facility which can operate under realistic gasification and combustion conditions. The major particulate control device issues to be addressed include the integration of the particulate control devices into coal utilization systems, on-line cleaning techniques, chemical and thermal degradation of components, fatigue or structural failures, blinding, collection efficiency as a function of particle size, and scale-up of particulate control systems to commercial size. The conceptual design of the facility was extended to include a within scope, phased expansion of the existing Hot Gas Cleanup Test Facility Cooperative Agreement to also address systems integration issues of hot particulate removal in advanced coal-based power generation systems. This expansion included the consideration of the following modules at the test facility in addition to the original Transport Reactor gas source and Hot Gas Cleanup Units: carbonizer/pressurized circulating fluidized bed gas source; hot gas cleanup units to mate to all gas streams; combustion gas turbine; and fuel cell and associated gas treatment. The major emphasis during this reporting period was continuing the detailed design of the facility and integrating the particulate control devices (PCDs) into structural and process designs. Substantial progress in underground construction activities was achieved during the quarter. Delivery and construction of coal handling and process structural steel began during the quarter. Delivery and construction of coal handling and process structural steel began during the quarter. MWK equipment at the grade level and the first tier are being set in the structure.

  13. Next Generation Pressurized Oxy-Coal Combustion: High Efficiency and No Flue Gas Recirculation

    Energy Technology Data Exchange (ETDEWEB)

    Rue, David

    2013-09-30

    The Gas Technology Institute (GTI) has developed a pressurized oxy-coal fired molten bed boiler (MBB) concept, in which coal and oxygen are fired directly into a bed of molten coal slag through burners located on the bottom of the boiler and fired upward. Circulation of heat by the molten slag eliminates the need for a flue gas recirculation loop and provides excellent heat transfer to steam tubes in the boiler walls. Advantages of the MBB technology over other boilers include higher efficiency (from eliminating flue gas recirculation), a smaller and less expensive boiler, modular design leading to direct scalability, decreased fines carryover and handling costs, smaller exhaust duct size, and smaller emissions control equipment sizes. The objective of this project was to conduct techno-economic analyses and an engineering design of the MBB project and to support this work with thermodynamic analyses and oxy-coal burner testing. Techno-economic analyses of GTI’s pressurized oxy-coal fired MBB technology found that the overall plant with compressed CO2 has an efficiency of 31.6%. This is a significant increase over calculated 29.2% efficiency of first generation oxy-coal plants. Cost of electricity (COE) for the pressurized MBB supercritical steam power plant with CO2 capture and compression was calculated to be 134% of the COE for an air-coal supercritical steam power plant with no CO2 capture. This compares positively with a calculated COE for first generation oxy-coal supercritical steam power plants with CO2 capture and compression of 164%. The COE for the MBB power plant is found to meet the U.S. Department of Energy (DOE) target of 135%, before any plant optimization. The MBB power plant was also determined to be simpler than other oxy-coal power plants with a 17% lower capital cost. No other known combustion technology can produce higher efficiencies or lower COE when CO2 capture and compression are included. A thermodynamic enthalpy and exergy analysis

  14. Efficiency enhancement in IGCC power plants with air-blown gasification and hot gas clean-up

    International Nuclear Information System (INIS)

    Giuffrida, Antonio; Romano, Matteo C.; Lozza, Giovanni

    2013-01-01

    Air-blown IGCC systems with hot fuel gas clean-up are investigated. In detail, the gas clean-up station consists of two reactors: in the first, the raw syngas exiting the gasifier and passed through high-temperature syngas coolers is desulfurized by means of a zinc oxide-based sorbent, whereas in the second the sulfided sorbent is duly regenerated. The hot fuel gas clean-up station releases H 2 S-free syngas, which is ready to fuel the combustion turbine after hot gas filtration, and a SO 2 -laden stream, which is successively treated in a wet scrubber. A thermodynamic analysis of two air-blown IGCC systems, the first with cold fuel gas clean-up and the second with hot fuel gas clean-up, both with a state-of-the-art combustion turbine as topping cycle, shows that it is possible to obtain a really attractive net efficiency (more than 51%) for the second system, with significant improvements in comparison with the first system. Nevertheless, higher efficiency is accomplished with a small reduction in the power output and no sensible efficiency improvements seem to be appreciated when the desulfurization temperature increases. Other IGCC systems, with an advanced 1500 °C-class combustion turbine as the result of technology improvements, are investigated as well, with efficiency as high as 53%. - Highlights: ► Hot fuel gas clean-up is a highly favorable technology for IGCC concepts. ► Significant IGCC efficiency improvements are possible with hot fuel gas clean-up. ► Size reductions of several IGCC components are possible. ► Higher desulfurization temperatures do not sensibly affect IGCC efficiency. ► IGCC efficiency as high as 53% is possible with a 1500°C-class combustion turbine

  15. Laboratory scale electron beam system for treatment of flue gases from diesel combustion

    International Nuclear Information System (INIS)

    Siti Aiasah Hashim; Khairul Zaman Mohd Dahlan; Khomsaton Abu Bakar; Ayub Muhammad

    2004-01-01

    Laboratory scale test rig to treat simulated flue gas using electron beam technology was installed at the Alurtron EB-Irradiation Center, MINT. The experiment test rig was proposed as a result of feasibility studies conducted jointly by IAEA, MINT and TNB Research in 1997. The test rig system consists of several components, among other, diesel generator sets, pipe ducts, spray cooler, ammonia dosage system, irradiation vessel, bag filter and gas analyzers. The installation was completed and commissioned in October 2001. results from the commissioning test runs and subsequent experimental work showed that the efficiency of flue gas treatment is high. It was proven that electron beam technology might be applied in the treatment of air pollutants. This paper describes the design and work function of the individual major components as well as the full system function. Results from the initial experimental works are also presented. (Author)

  16. Mercury isotope signatures of seawater discharged from a coal-fired power plant equipped with a seawater flue gas desulfurization system.

    Science.gov (United States)

    Lin, Haiying; Peng, Jingji; Yuan, Dongxing; Lu, Bingyan; Lin, Kunning; Huang, Shuyuan

    2016-07-01

    Seawater flue gas desulfurization (SFGD) systems are commonly used to remove acidic SO2 from the flue gas with alkaline seawater in many coastal coal-fired power plants in China. However, large amount of mercury (Hg) originated from coal is also transferred into seawater during the desulfurization (De-SO2) process. This research investigated Hg isotopes in seawater discharged from a coastal plant equipped with a SFGD system for the first time. Suspended particles of inorganic minerals, carbon residuals and sulfides are enriched in heavy Hg isotopes during the De-SO2 process. δ(202)Hg of particulate mercury (PHg) gradually decreased from -0.30‰ to -1.53‰ in study sea area as the distance from the point of discharge increased. The results revealed that physical mixing of contaminated De-SO2 seawater and uncontaminated fresh seawater caused a change in isotopic composition of PHg isotopes in the discharging area; and suggested that both De-SO2 seawater and local background contributed to PHg. The impacted sea area predicted with isotopic tracing technique was much larger than that resulted from a simple comparison of pollutant concentration. It was the first attempt to apply mercury isotopic composition signatures with two-component mixing model to trace the mercury pollution and its influence in seawater. The results could be beneficial to the coal-fired plants with SFGD systems to assess and control Hg pollution in sea area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. High-BTU gas production from tar-bearing hot coke oven gas over iron catalyst

    Energy Technology Data Exchange (ETDEWEB)

    L.Y. Li; K. Morishita; T. Takarada [Gunma University, Gunma (Japan). Department of Biological and Chemical Engineering

    2005-07-01

    To utilize the tar-bearing hot coke oven gas (the by-product of coke making process) more effectively, a process was developed by converting the hot coke oven gas into a methane rich high-BTU gas over iron-bearing catalysts. The catalytic behaviour of Indonesian limonite ore was mainly discussed. For a reference, a conventional nickel catalyst (Ni/Al{sub 2}O{sub 3}) was employed. Laboratory scale tests were carried out in a two-stage fixed-bed reactor at ambient pressure. A bituminous coal sample was heated at first stage, the volatiles was carried by feed gas and decomposed at second stage. The limonite promoted hydropyrolysis of coal volatiles similar to Ni/Al{sub 2}O{sub 3} catalyst. High yields of total product gas and methane were obtained at 50 vol.% hydrogen atmosphere with a feed gas of 60 ml min{sup -1} hydrogen and 60 ml min{sup -1} nitrogen. After experiments, hydrocarbons heavier than ethane were not observed. Also that, carbon balance was more than 99.8% in coal char, product gases and carbon deposits. It was considered that coal volatiles converted into light gases and carbon almost completely in catalyst bed. Yields of product gas and methane depended upon catalytic temperature. At 923 K, the maximum yield of product gas was achieved at 74.3% for limonite catalyst on carbon balance with methane 83.2 vol.% of the carbonaceous gas products. Comparing with limonite, Fe/Al{sub 2}O{sub 3} and BOF dust samples showed low activities on coal volatiles catalytic decomposition. 21 refs., 5 figs., 3 tabs.

  18. Savings on natural gas consumption by doubling thermal efficiencies of balanced-flue space heaters

    Energy Technology Data Exchange (ETDEWEB)

    Juanico, Luis E. [Conicet, and Centro Atomico Bariloche e Instituto Balseiro, Av. Bustillo 9500, 8400 Bariloche, Rio Negro (Argentina); Gonzalez, Alejandro D. [Grupo de Estudios Ambientales, Instituto de Investigaciones en Biodiversidad y Medio Ambiente (Inibioma-Conicet), 8400 Bariloche, Rio Negro (Argentina)

    2008-07-01

    Natural gas is a relatively clean fossil fuel for space heating. However, when it is not used efficiently high consumption can become an environmental problem. In Argentina, individual balanced-flue space heaters are the most extensively used in temperate and cold regions. This furnace is a simple device with a burner set into a metal chamber, separated from the indoor ambient by an enclosing cabinet, and both inlet and outgas chimneys are connected to the outdoor ambient. In previous studies, we measured the performance of these commercial devices, and found very low thermal efficiency (in the range of 39-63% depending on the chimney configuration). The extensive use of these devices is possible due to the availability of unlimited amount of subsidised natural gas to households and businesses. In the present work, we developed a prototype with simple and low cost modifications made on commercial models, and measured the improvements on the thermal efficiency. Findings showed better infrared radiation, enhanced indoor air convection, and passive chimney flow regulation leading to thermal efficiency in the range of 75-85%. These values represent an improvement of 100% when compared to marketed models, and hence, the specific cost of the heater per unit of useful heating power delivered was actually reduced. Considering the large market presence of these furnaces in both residential and business sectors in Argentina, the potential benefits related to gas consumption and environmental emissions are very significant. (author)

  19. Management of dry flue gas desulfurization by-products in underground mines. Annual report, October 1994--September 1995

    Energy Technology Data Exchange (ETDEWEB)

    Chugh, Y.P.; Dutta, D.; Esling, S. [and others

    1995-10-01

    On September 30, 1993, the U.S. Department of Energy-Morgantown Energy Technology Center (DOE-METC) and Southern Illinois University at Carbondale (SIUC) entered into a cooperative research agreement entitled {open_quotes}Management of Dry Flue Gas Desulfurization By-Products in Underground Mines{close_quotes} (DE-FC21-93MC30252). Under the agreement Southern Illinois University at Carbondale will develop and demonstrate several technologies for the placement of coal combustion residues (CCBs) in abandoned coal mines, and will assess the environmental impact of such underground CCB placement. This report describes progress in the following areas: environmental characterization, mix development and geotechnical characterization, material handling and system economics, underground placement, and field demonstration.

  20. Applying ACF to desulfurization process from flue gas

    International Nuclear Information System (INIS)

    Liu Yi; Zhang Zhigang; Tang Qiang; Cao Zidong

    2004-01-01

    Inasmuch as the status of environmental pollution caused by SO 2 is more and more serious and the policy of environmental protection is executed more and more strictly, desulfurization from flue gas (FGD) is introduced to a wide-spread field of national economy. By a comparison with lime-limestone method, the application of adsorption method in FGD is more effective in desulfurization and more adapted to the situation of our country in respect of its more valuable byproduct. However, the technique of adsorption method is limited by the large amount of adsorbent used. In this paper, activated carbon fiber (ACF) is proposed as a new type of adsorbent to apply in FGD. A series of experiments have been made in order to compare the performances between ACF and granular activated carbon (GAC) which has been mostly used. Experiments show that under the same working conditions ACF's adsorption capacity is 16.6 times as high as that of GAC, mass loss rate is 1/12 of GAC's, desorption efficiency of ACF can reach 99.9%. The theory of micropore adsorption dynamics is adopted to analyze the characteristics of both adsorbents. It is indicated that adsorbability and perfectibility of desorption are tightly related to the distribution of pores and the surface micromechanism of adsorbent surface. The accessibility of pores for specified adsorptive and the effects of capillary condensation are crucial factors to influence the process of FGD. According to the research of different adsorbents, conclusion can be drawn that ACF is a kind of good material with a strong selectivity for SO 2 . Compared with the traditional methods of FGD, the use of ACF can greatly economize the consumption of adsorbent and obviously reduce the introduction of new adsorbent, and at the same time keep down the equipment investment and operating cost. (authors)

  1. The effect of carbon dioxide during the desulfurization of flue gas with Mardin-Mazidagi phosphate rock

    Energy Technology Data Exchange (ETDEWEB)

    Melike Sinirkaya; Hatice Bayrakceken; A. Kadir Ozer; M. Sahin Gulaboglu [Ataturk University, Erzurum (Turkey). Department of Chemical Engineering

    2008-11-15

    The effects of temperature, CO{sub 2} concentration and particle size on simultaneous calcination/sulfation of Mardin-Mazidagi phosphate rock in fluidized-bed reactor were investigated. For this, a raw sample was exposed to calcination and sulfation processes in a fluidized-bed reactor to determine the effects of parameters by using a model gas mixture similar to the flue gas composition. The calcination ratio increased with increasing temperature and decreasing particle size, but decreased with increasing CO{sub 2} concentration. In sulfation process, however, sulphate conversion ratio increased with increasing CO{sub 2} ratio and decreased with decreasing particle size. The sulfation reaction is well represented by the shrinking core model and can be divided into two regions with different rate controlling step. For low conversions, the controlling step was found to be chemical reaction at the interface, but the diffusion through the product layer for high conversion. The activation energies for the chemical reaction at the interface and diffusion through the product layer cases were calculated as 100 and 296 kJ mol{sup -1}, respectively. 23 refs., 13 figs., 1 tab.

  2. Simulation of a bubbling fluidized bed process for capturing CO2 from flue gas

    International Nuclear Information System (INIS)

    Choi, Jeong-Hoo; Yi, Chang-Keun; Jo, Sung-Ho; Ryu, Ho-Jung; Park, Young-Cheol

    2014-01-01

    We simulated a bubbling bed process capturing CO 2 from flue gas. It applied for a laboratory scale process to investigate effects of operating parameters on capture efficiency. The adsorber temperature had a stronger effect than the regenerator temperature. The effect of regenerator temperature was minor for high adsorber temperature. The effect of regenerator temperature decreased to level off for the temperature >250 .deg. C. The capture efficiency was rather dominated by the adsorption reaction than the regeneration reaction. The effect of gas velocity was as appreciable as that of adsorber temperature. The capture efficiency increased with the solids circulation rate since it was ruled by the molar ratio of K to CO 2 for solids circulation smaller than the minimum required one (G s, min ). However, it leveled off for solids circulation rate >G s, min . As the ratio of adsorber solids inventory to the total solids inventory (x w1 ) increased, the capture efficiency increased until x w1 =0.705, but decreased for x w1 >0.705 because the regeneration time decreased too small. It revealed that the regeneration reaction was faster than the adsorption reaction. Increase of total solids inventory is a good way to get further increase in capture efficiency

  3. Modelling of hot surface ignition within gas turbines subject to flammable gas in the intake

    DEFF Research Database (Denmark)

    Pedersen, Lea Duedahl; Nielsen, Kenny Krogh; Yin, Chungen

    2017-01-01

    Controlling risks associated with fires and explosions from leaks of flammable fluids at oil and gas facilities is paramount to ensuring safe operations. The gas turbine is a significant potential source of ignition; however, the residual risk is still not adequately understood. A model has been...... but decreases with increase in initial mixture temperature and pressure. The model shows a great potential in reliable prediction of the risk of hot surface ignition within gas turbines in the oil and gas industry. In the future, a dedicated experimental study will be performed not only to improve...

  4. Hot gas cleanup test facility for gasification and pressurized combustion. Quarterly technical progress report, July 1--September 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1992-12-31

    The objective of this project is to evaluate hot gas particle control technologies using coal-derived gas streams. This will entail the design, construction, installation, and use of a flexible test facility which can operate under realistic gasification and combustion conditions. The major particulate control device issues to be addressed include the integration of the particulate control devices into coal utilization systems, on-line cleaning techniques, chemical and thermal degradation of components, fatigue or structural failures, blinding, collection efficiency as a function of particle size, and scale-up of particulate control systems to commercial size. The conceptual design of the facility was extended to include a within scope, phased expansion of the existing Hot Gas Cleanup Test Facility Cooperative Agreement to also address systems integration issues of hot particulate removal in advanced coal-based power generation systems. This expansion included the consideration of the following modules at the test facility in addition to the existing Transport Reactor gas source and Hot Gas Cleanup Units: Carbonizer/Pressurized Circulating Fluidized Bed Gas Source; hot Gas Cleanup Units to mate to all gas streams; and Combustion Gas Turbine. Fuel Cell and associated gas treatment. This expansion to the Hot Gas Cleanup Test Facility is herein referred to as the Power Systems Development Facility (PSDF).

  5. Effect of process parameters on power requirements of vacuum swing adsorption technology for CO2 capture from flue gas

    International Nuclear Information System (INIS)

    Zhang, Jun; Webley, Paul A.; Xiao, Penny

    2008-01-01

    This study focuses on the effects of process and operating parameters - feed gas temperature, evacuation pressure and feed concentration - on the performance of carbon dioxide vacuum swing adsorption (CO 2 VSA) processes for CO 2 capture from gas, especially as it affects power consumption. To obtain reliable data on the VSA process, experimental work was conducted on a purposely built three bed CO 2 VSA pilot plant using commercial 13X zeolite. Both 6 step and 9 step cycles were used to determine the influences of temperature, evacuation pressure and feed concentration on process performance (recovery, purity, power and corresponding capture cost). A simple economic model for CO 2 capture was developed and employed herein. Through experiments and analysis, it is found that the feed gas temperature, evacuation pressure and feed concentration have significant effects on power consumption and CO 2 capture cost. Our data demonstrate that the CO 2 VSA process has good recovery (>70%), purity (>90%) and low power cost (4-10 kW/TPDc) when operating with 40 C feed gas provided relatively deep vacuum is used. Enhanced performance is obtained when higher feed gas concentration is fed to the plant, as expected. Our data indicates large potential for application of CO 2 VSA to CO 2 capture from flue gas. (author)

  6. Reclamation of acid, toxic coal spoils using wet flue gas desulfurization by-product, fly ash and sewage sludge. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kost, D.A.; Vimmerstedt, J.P.; Stehouwer, R.C.

    1997-03-01

    Establishment of vegetation on acid abandoned minelands requires modification of soil physical and chemical conditions. Covering the acid minesoil with topsoil or borrow soil is a common practice but this method may be restricted by availability of borrow soil and cause damage to the borrow site. An alternative approach is to use waste materials as soil amendments. There is a long history of using sewage sludge and fly ash as amendments for acid minesoils. Flue gas desulfurization (FGD) by-products are newer materials that are also promising amendments. Most flue gas sludges are mixtures of Calcium sulfate (CaSO{sub 4}), calcium sulfite (CaSO{sub 3}), calcium carbonate (CaCO{sub 3}), calcium hydroxide [Ca(OH){sub 2}], and fly ash. Some scrubbing processes produce almost pure gypsum (CaSO{sub 4}2H{sub 2}O). The primary purpose of the project is to evaluate two wet FGD by-products for effects on vegetation establishment and surface and ground water quality on an acid minesoil. One by-product from the Conesville, OH power plant (American Electric Power Service Corporation) contains primarily calcium sulfite and fly ash. The other by-product (Mg-gypsum FGD) from an experimental scrubber at the Zimmer power plant (Cincinnati Gas and Electric Company) is primarily gypsum with 4% magnesium hydroxide. These materials were compared with borrow soil and sewage sludge as minesoil amendments. Combinations of each FGD sludge with sewage sludge were also tested. This report summarizes two years of measurements of chemical composition of runoff water, ground water at two depths in the subsoil, soil chemical properties, elemental composition and yield of herbaceous ground cover, and elemental composition, survival and height of trees planted on plots treated with the various amendments. The borrow soil is the control for comparison with the other treatments.

  7. Reclamation of acid, toxic coal spoils using wet flue gas desulfurization by-product, fly ash and sewage sludge. Final report

    International Nuclear Information System (INIS)

    Kost, D.A.; Vimmerstedt, J.P.; Stehouwer, R.C.

    1997-03-01

    Establishment of vegetation on acid abandoned minelands requires modification of soil physical and chemical conditions. Covering the acid minesoil with topsoil or borrow soil is a common practice but this method may be restricted by availability of borrow soil and cause damage to the borrow site. An alternative approach is to use waste materials as soil amendments. There is a long history of using sewage sludge and fly ash as amendments for acid minesoils. Flue gas desulfurization (FGD) by-products are newer materials that are also promising amendments. Most flue gas sludges are mixtures of Calcium sulfate (CaSO 4 ), calcium sulfite (CaSO 3 ), calcium carbonate (CaCO 3 ), calcium hydroxide [Ca(OH) 2 ], and fly ash. Some scrubbing processes produce almost pure gypsum (CaSO 4 2H 2 O). The primary purpose of the project is to evaluate two wet FGD by-products for effects on vegetation establishment and surface and ground water quality on an acid minesoil. One by-product from the Conesville, OH power plant (American Electric Power Service Corporation) contains primarily calcium sulfite and fly ash. The other by-product (Mg-gypsum FGD) from an experimental scrubber at the Zimmer power plant (Cincinnati Gas and Electric Company) is primarily gypsum with 4% magnesium hydroxide. These materials were compared with borrow soil and sewage sludge as minesoil amendments. Combinations of each FGD sludge with sewage sludge were also tested. This report summarizes two years of measurements of chemical composition of runoff water, ground water at two depths in the subsoil, soil chemical properties, elemental composition and yield of herbaceous ground cover, and elemental composition, survival and height of trees planted on plots treated with the various amendments. The borrow soil is the control for comparison with the other treatments

  8. A novel oxidative method for the absorption of Hg0 from flue gas of coal fired power plants using task specific ionic liquid scrubber

    International Nuclear Information System (INIS)

    Barnea, Zach; Sachs, Tatyana; Chidambaram, Mandan; Sasson, Yoel

    2013-01-01

    Highlights: ► Ionic liquid used as absorption media due to negligible vapor pressure. ► Formation of a stable complex between the oxidation agent and the absorption liquid prevents its sublimation. ► Remarkable concentration factor of six orders of magnitude of mercury/IL unlike active carbon injection that absorb ppb of Hg from flue. ► Reduced metallic mercury swiftly precipitated from the solution and could be quantitatively separated and collected. -- Abstract: A simple continuous process is described for the removal of mercury from gas streams (such as flue gas of a coal fired power stations) using imidazolium based Task Specific Ionic Liquids [TSILs] with the general structure ([RMIM][XI 2 − ]) where X = Cl, Br or I. The latter are formed by blending dialkylimidazolium halide salts with iodine. When applied in a gas/liquid scrubber, these salts were shown to absorb >99% of elemental mercury originally present in a gas stream in concentration of 75–400 ppb. The mercury abatement is attained by oxidating the mercury to HgI 2 which is bound as a stable IL complex ([RMIM + ][XHgI 2 − ]. The novel absorption system exhibits a remarkable mercury concentration factor of seven orders of magnitude. The final solution obtained contains up to 50% (w/w) mercury in the IL. Upon exposure to sodium formate, directly added to the saturated IL at 45 °C, reduced metallic mercury swiftly precipitated from the solution and could be quantitatively separated and collected. The free IL could be fully recycled

  9. Photooxidative removal of Hg0 from simulated flue gas using UV/H2O2 advanced oxidation process: Influence of operational parameters

    International Nuclear Information System (INIS)

    Zhang, Bo; Zhong, Zhaoping; Ding, Kuan; Yu, Lulu

    2014-01-01

    Element mercury (Hg 0 ) from flue gas is difficult to remove because of its low solubility in water and high volatility. A new technology for photooxidative removal of Hg 0 with an ultraviolet (UV)/H 2 O 2 advanced oxidation process is studied in an efficient laboratory-scale bubble column reactor. Influence of several key operational parameters on Hg 0 removal efficiency is investigated. The results show that an increase in the UV light power, H 2 O 2 initial concentration or H 2 O 2 solution volume will enhance Hg 0 removal. The Hg 0 removal is inhibited by an increase of the Hg 0 initial concentration. The solution initial pH and pH conditioning agent have a remarkable synergistic effect. The highest Hg 0 removal efficiencies are achieved at the UV light power of 36W, H 2 O 2 initial concentration of 0.125 mol/L, Hg 0 initial concentration of 25.3 - g/Nm 3 , solution initial pH of 5, H 2 O 2 solution volume of 600 ml, respectively. In addition, the O 2 percentage has little effect on the Hg 0 removal efficiency. This study is beneficial for the potential practical application of Hg 0 removal from coal-fired flue gas with UV/H 2 O 2 advanced oxidation process

  10. Investigation of the biofuel flue and producer gases cleaning efficiency using ESP

    Science.gov (United States)

    Poškas, Robertas; Sirvydas, Arūnas; Poškas, Povilas; Striūgas, Nerijus; Pedišius, Nerijus; Valinčius, Vitas

    2017-11-01

    The use of biofuel has been increasing in Europe over the last years, and the reason for that is acceptable cost and the least negative impact on the environment. However, NOx and emissions of fine particulates are important, and biofuel is still a disadvantage compared to oil and natural gas fired systems. Usually, flue gas is filtered in multicyclones or fibre filters before discharge into the atmosphere. Yet, in the case of fine particulates, the filters of such type do not show high effectiveness, thus electrostatic precipitators are used. In this comparative study on biofuel (wood pellets), the collection efficiency of solid particles from a class 3 boiler (50 kW) and from a gasification unit (100 kW) was investigated. Although releases of solid particles from modern boilers are low, a combination of such a boiler with an electrostatic precipitator may reduce the releases of particles to the minimum, and the collection efficiency of the electrostatic precipitator obtained during the investigation was 98-99%. There is a big difference in particle concentrations comparing the systems with flue gas and producer gas. As the working conditions in the test section with producer gas were harder, it led to lower efficiency of the electrostatic precipitator ( 75%).

  11. Investigation of the biofuel flue and producer gases cleaning efficiency using ESP

    Directory of Open Access Journals (Sweden)

    Poškas Robertas

    2017-01-01

    Full Text Available The use of biofuel has been increasing in Europe over the last years, and the reason for that is acceptable cost and the least negative impact on the environment. However, NOx and emissions of fine particulates are important, and biofuel is still a disadvantage compared to oil and natural gas fired systems. Usually, flue gas is filtered in multicyclones or fibre filters before discharge into the atmosphere. Yet, in the case of fine particulates, the filters of such type do not show high effectiveness, thus electrostatic precipitators are used. In this comparative study on biofuel (wood pellets, the collection efficiency of solid particles from a class 3 boiler (50 kW and from a gasification unit (100 kW was investigated. Although releases of solid particles from modern boilers are low, a combination of such a boiler with an electrostatic precipitator may reduce the releases of particles to the minimum, and the collection efficiency of the electrostatic precipitator obtained during the investigation was ~98-99%. There is a big difference in particle concentrations comparing the systems with flue gas and producer gas. As the working conditions in the test section with producer gas were harder, it led to lower efficiency of the electrostatic precipitator (~75%.

  12. Microbial reduction of SO{sub 2} and NO{sub x} as a means of by-product recovery/disposal from regenerable processes for the desulfurization of flue gas. Technical progress report, March 11, 1993--June 11, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Sublette, K.L.

    1993-11-01

    There are two basic approaches to addressing the problem of SO{sub 2} and NO{sub x} emissions: (1) desulfurize (and denitrogenate) the feedstock prior to or during combustion; or (2) scrub the resultant SO{sub 2} and oxides of nitrogen from the boiler flue gases. The flue gas processing alternative has been addressed in this project via microbial reduction of SO{sub 2} and NO{sub x} by sulfate-reducing bacteria

  13. Review of hot corrosion of thermal barrier coatings of gas turbine

    Directory of Open Access Journals (Sweden)

    LIU Yongbao

    2017-03-01

    Full Text Available The review was done in order to make clear the problem of the hot corrosion of the Thermal Barrier Coatings(TBCsduring gas turbine serving. This paper summarizes the factors resulting from the hot corrosion of TBCs during turbine service and classifies methods for enhancing the corrosive resistance of TBCs. A prospective methodology for improving corrosion resistance is also formulated. The main types of corrosion coating include phase reaction, oxidizing of the bond coating, salt-fog corrosion, CMAS corrosion and fuel impurity corrosion. So far, methods for improving the corrosion resistance of TBCs include developing new coating materials, anticorrosive treatment on the surface of TBCs, modifying the stacking configuration and improving the cleansing functions of the gas turbines. In the future, developing new materials with excellent performance will still be the main direction for boosting the improvement of the hot corrosion resistance of TBCs. Simultaneously, improving the tacking configuration and nanotechnology of TBC coatings are potential approaches for improving corrosion resistance. With the development of a Ceramic Matrix Composite (CMC, the focus of the hot corrosion of TBCs may turn to that of Environmental Barrier Coatings (EBCs.

  14. A GIS based national assessment of algal bio-oil production potential through flue gas and wastewater co-utilization

    International Nuclear Information System (INIS)

    Orfield, Nolan D.; Keoleian, Gregory A.; Love, Nancy G.

    2014-01-01

    The high theoretical productivity of microalgae makes it a promising energy crop, but economically viable large-scale production facilities have yet to emerge. Coupling algae cultivation ponds with flue gas emissions from power utilities to provide carbon dioxide and municipal wastewater to provide nutrients has been recommended as a solution. This flue gas and wastewater co-utilization (FWC) strategy not only reduces the upstream impacts and costs associated with providing inputs, but also provides a credit for wastewater treatment, a service currently required to reduce production costs to a viable level. This study provides the first national assessment of the potential for producing algal bio-oil in the United States using FWC. Spatial-temporal algae growth was simulated using solar radiation and temperature data to calculate the average annual algae yield for any location, which significantly impacts feasibility. The results of this model were integrated into a geospatial analysis which establishes the economically viable bio-oil production potential of FWC by accounting for the relative abundance of the input resources and their proximity. At most, 1.7 billion liters of bio-oil could be produced annually in a manner economically competitive with crude oil prices of $80 per barrel. The amount of nutrients in wastewater limits yields to 20.5 L of bio-oil per capita annually, and climatic constraints further reduce this potential by nearly 60%. Carbon dioxide constraints play a negligible role. Although the bio-oil production potential of FWC is relatively small, it does provide an opportunity to increase national biofuel output while providing a needed service. - Highlights: • Spatial-temporal algae growth was simulated using historical climate data. • A geospatial overlay analysis was used to assess national production potential. • Nutrient availability in wastewater is most limiting. • At most, 1.7 billion liters of algal biofuel per year could be

  15. Removal potential of toxic 2378-substituted PCDD/F from incinerator flue gases by waste-derived activated carbons.

    Science.gov (United States)

    Hajizadeh, Yaghoub; Onwudili, Jude A; Williams, Paul T

    2011-06-01

    The application of activated carbons has become a commonly used emission control protocol for the removal or adsorption of persistent organic pollutants from the flue gas streams of waste incinerators. In this study, the 2378-substituted PCDD/F removal efficiency of three types of activated carbons derived from the pyrolysis of refuse derived fuel, textile waste and scrap tyre was investigated and compared with that of a commercial carbon. Experiments were carried out in a laboratory scale fixed-bed reactor under a simulated flue gas at 275°C with a reaction period of four days. The PCDD/F in the solid matrices and exhaust gas, were analyzed using gas chromatography coupled with a triple quadrupole mass spectrometer. In the absence of activated carbon adsorbent, there was a significant increase in the concentration of toxic PCDD/F produced in the reacted flyash, reaching up to 6.6 times higher than in the raw flyash. In addition, there was a substantial release of PCDD/F into the gas phase, which was found in the flue gas trapping system. By application of the different commercial, refuse derived fuel, textile and tyre activated carbons the total PCDD/F toxic equivalent removal efficiencies in the exhaust gas stream were 58%, 57%, 64% and 52%, respectively. In general, the removal of the PCDDs was much higher with an average of 85% compared to PCDFs at 41%. Analysis of the reacted activated carbons showed that there was some formation of PCDD/F, for instance, a total of 60.6 μg I-TEQ kg(-1) toxic PCDD/F was formed in the refuse derived fuel activated carbon compared to 34 μg I-TEQ kg(-1) in the commercial activated carbon. The activated carbons derived from the pyrolysis of waste, therefore, showed good potential as a control material for PCDD/F emissions in waste incinerator flue gases. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Research on thermal insulation for hot gas ducts

    International Nuclear Information System (INIS)

    Broeckerhoff, P.

    1984-01-01

    The inner surfaces of prestressed reactor vessels and hot gas ducts of Gas Cooled High Temperature Reactors need internal thermal insulation to protect the pressure bearing walls from high temperatures. The design parameters of the insulation depend on the reactor type. In a PNP-plant temperature and pressure of the cooling medium helium are proposed to be 950 deg. C and 40 bars, respectively. The experimental work was started at KFA in 1971 for the HHT-project using three test facilities. At first metallic foil insulation and stuffed fibre insulating systems, the hot gas ducting shrouds of which were made of metal, have been tested. Because of the elevated helium temperature in case of PNP and the resulting lower strength of the metallic parts the interest was directed to rigid ceramic materials for the spacers and the inner shrouds. This led to modified structures designed by the INTERATOM company. Tests were performed at KFA. The main object of the investigations was to study the influence of temperature, pressure and axial pressure gradients on the thermal efficiency of the structures. Moreover, the temperatures within the insulation, at the pressure tube, and at the elements which bear the inner shrouds were measured. Thermal fluxes and effective thermal conductivities in axial and circumferential direction of the pressure tube are given, mainly for the INTERATOM-design with spherical spacers. (author)

  17. Integrated removal of NO and mercury from coal combustion flue gas using manganese oxides supported on TiO2.

    Science.gov (United States)

    Zhang, Shibo; Zhao, Yongchun; Wang, Zonghua; Zhang, Junying; Wang, Lulu; Zheng, Chuguang

    2017-03-01

    A catalyst composed of manganese oxides supported on titania (MnO x /TiO 2 ) synthesized by a sol-gel method was selected to remove nitric oxide and mercury jointly at a relatively low temperature in simulated flue gas from coal-fired power plants. The physico-chemical characteristics of catalysts were investigated by X-ray fluorescence (XRF), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) analyses, etc. The effects of Mn loading, reaction temperature and individual flue gas components on denitration and Hg 0 removal were examined. The results indicated that the optimal Mn/Ti molar ratio was 0.8 and the best working temperature was 240°C for NO conversion. O 2 and a proper ratio of [NH 3 ]/[NO] are essential for the denitration reaction. Both NO conversion and Hg 0 removal efficiency could reach more than 80% when NO and Hg 0 were removed simultaneously using Mn0.8Ti at 240°C. Hg 0 removal efficiency slightly declined as the Mn content increased in the catalysts. The reaction temperature had no significant effect on Hg 0 removal efficiency. O 2 and HCl had a promotional effect on Hg 0 removal. SO 2 and NH 3 were observed to weaken Hg 0 removal because of competitive adsorption. NO first facilitated Hg 0 removal and then had an inhibiting effect as NO concentration increased without O 2 , and it exhibited weak inhibition of Hg 0 removal efficiency in the presence of O 2 . The oxidation of Hg 0 on MnO x /TiO 2 follows the Mars-Maessen and Langmuir-Hinshelwood mechanisms. Copyright © 2016. Published by Elsevier B.V.

  18. Recovery of SO2 and MgO from By-Products of MgO Wet Flue Gas Desulfurization.

    Science.gov (United States)

    Yan, Liyun; Lu, Xiaofeng; Wang, Quanhai; Guo, Qiang

    2014-11-01

    An industrial demonstration unit using natural gas as a heat source was built to calcine the by-products of MgO wet flue gas desulfurization from power plants; influencing factors on the SO 2 content in calciner gas were comprehensively analyzed; and an advantageous recycling condition of MgO and SO 2 from by-products was summarized. Results showed that the SO 2 content in the calciner gas was increased by more than 10 times under a lower excess air coefficient, a higher feed rate, a lower crystal water in by-products, and a higher feed port position. For the tests conducted under the excess air coefficient above and below one, the effect of the furnace temperature on the SO 2 content in the calciner gas was reversed. Results of activity analysis indicate that particles of MgO generated under the calcination temperature of 900-1,000°C had a high activity. In contrast, due to the slight sintering, MgO generated under the calcination temperature of 1,100°C had a low activity. To recycle SO 2 as well as MgO, a temperature range of 900-927°C for TE103 is proposed. These studies will prompt the desulfurization market diversification, reduce the sulfur's dependence on imports for making sulfuric acid, be meaningful to balance the usage of the natural resource in China, and be regarded as a reference for the development of this technology for other similar developing countries.

  19. Slipstream pilot-scale demonstration of a novel amine-based post-combustion technology for carbon dioxide capture from coal-fired power plant flue gas

    Energy Technology Data Exchange (ETDEWEB)

    Krishnamurthy, Krish R. [Linde LLC, Murray Hill, NJ (United States)

    2017-02-03

    Post-combustion CO2 capture (PCC) technology offers flexibility to treat the flue gas from both existing and new coal-fired power plants and can be applied to treat all or a portion of the flue gas. Solvent-based technologies are today the leading option for PCC from commercial coal-fired power plants as they have been applied in large-scale in other applications. Linde and BASF have been working together to develop and further improve a PCC process incorporating BASF’s novel aqueous amine-based solvent technology. This technology offers significant benefits compared to other solvent-based processes as it aims to reduce the regeneration energy requirements using novel solvents that are very stable under the coal-fired power plant feed gas conditions. BASF has developed the desired solvent based on the evaluation of a large number of candidates. In addition, long-term small pilot-scale testing of the BASF solvent has been performed on a lignite-fired flue gas. In coordination with BASF, Linde has evaluated a number of options for capital cost reduction in large engineered systems for solvent-based PCC technology. This report provides a summary of the work performed and results from a project supported by the US DOE (DE-FE0007453) for the pilot-scale demonstration of a Linde-BASF PCC technology using coal-fired power plant flue gas at a 1-1.5 MWe scale in Wilsonville, AL at the National Carbon Capture Center (NCCC). Following a project kick-off meeting in November 2011 and the conclusion of pilot plant design and engineering in February 2013, mechanical completion of the pilot plant was achieved in July 2014, and final commissioning activities were completed to enable start-up of operations in January 2015. Parametric tests were performed from January to December 2015 to determine optimal test conditions and evaluate process performance over a variety of operation parameters. A long-duration 1500-hour continuous test campaign was performed from May to

  20. Robust C–C bonded porous networks with chemically designed functionalities for improved CO2 capture from flue gas

    Directory of Open Access Journals (Sweden)

    Damien Thirion

    2016-10-01

    Full Text Available Effective carbon dioxide (CO2 capture requires solid, porous sorbents with chemically and thermally stable frameworks. Herein, we report two new carbon–carbon bonded porous networks that were synthesized through metal-free Knoevenagel nitrile–aldol condensation, namely the covalent organic polymer, COP-156 and 157. COP-156, due to high specific surface area (650 m2/g and easily interchangeable nitrile groups, was modified post-synthetically into free amine- or amidoxime-containing networks. The modified COP-156-amine showed fast and increased CO2 uptake under simulated moist flue gas conditions compared to the starting network and usual industrial CO2 solvents, reaching up to 7.8 wt % uptake at 40 °C.