WorldWideScience

Sample records for hot box detectors

  1. Determination of a source in a box with two detectors. I. non-absorbing media

    CERN Document Server

    Presler, O; German, U; Leichter, Y; Alfassi, Z B

    2002-01-01

    It was found that the activity and the position of a radioactive point source (hot spot) in a large box containing low absorbing material can be measured accurately using two NaI(Tl) gamma-ray detectors at the opposite sides of the box i.e. at 180 deg. one to another. The harmonic mean of the count rates square roots measured with the two detectors was found to be independent of the hot spot position and depends only on the source activity, the box size and the gamma-rays energy. The activity of the radioactive point source can be calculated from the above-mentioned mean. The position of the point source can be calculated from the ratio of the two detectors count rates.

  2. Experimental study of multipurpose solar hot box at Freiburg, Germany

    Energy Technology Data Exchange (ETDEWEB)

    Nandwani, S.S. [Iowa State University, Ames (United States). International Inst. of Theoretical and Applied Physics; Steinhart, J.; Henning, H.M.; Rommel, M.; Wittwer, V. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany)

    1997-12-31

    With the aim to test an compare some properties of materials and common geometries that are used for designing solar cookers, water heaters, etc. we have made a solar hot box with two similar compartments. In the present study this hot box has been used for, (a) comparing the behavior of a metallic slab filled with a phase change material for short term heat storage, with a conventional absorbing sheet, (b) the use of a selectively coated, as compared to a normal black painted, cooking pot, and (c) for finding the overall heat loss coefficient and thermal capacity of the box. Experiments with the solar hot box will yield valuable information on solar systems that are to be constructed. Besides its use for research this multi-purpose device has been used both to pasteurize up to 14-16 l of water and for cooking. (author)

  3. Light box for investigation of characteristics of optoelectronics detectors

    Science.gov (United States)

    Szreder, Agnieszka; Mazikowski, Adam

    2017-09-01

    In this paper, a light box for investigation of characteristics of optoelectronic detectors is described. The light box consists of an illumination device, an optical power sensor and a mechanical enclosure. The illumination device is based on four types of high-power light emitting diodes (LED): white light, red, green and blue. The illumination level can be varied for each LED independently by the driver and is measured by optical power sensor. The mechanical enclosure provides stable mounting points for the illumination device, sensor and the examined detector and protects the system from external light, which would otherwise strongly influence the measurement results. Uniformity of illumination distribution provided by the light box for all colors is good, making the measurement results less dependent on the position of the examined detector. The response of optoelectronic detectors can be investigated using the developed light box for each LED separately or for any combination of up to four LED types. As the red, green and blue LEDs are rather narrow bandwidth sources, spectral response of different detectors can be examined for these wavelength ranges. The described light box can be used for different applications. Its primary use is in a student laboratory setup for investigation of characteristics of optoelectronic detectors. Moreover, it can also be used in various colorimetric or photographic applications. Finally, it will be used as a part of demonstrations from the fields of vision and color, performed during science fairs and outreach activities increasing awareness of optics and photonics.

  4. Measuring Pu in a glove box using portable NaI and germanium detectors

    International Nuclear Information System (INIS)

    Hankins, D.E.

    1984-01-01

    A NaI crystal or germanium detector inside a portable lead shield can determine the amount of plutonium in a glove box. The number of counts required are defined and the locations outside the box where the detector needs to be positioned are given. The calculated accuracy for measuring the Pu when these locations are used is within +/-30% for most glove boxes. Other factors that may affect this accuracy, such as γ-ray absorption by glove-box materials, self-absorption by Pu, absorption by equipment in the glove box, and the limits of the counting equipment are also discussed

  5. AstroBox2 – Detector for low-energy β-delayed particle detection

    Energy Technology Data Exchange (ETDEWEB)

    Saastamoinen, A., E-mail: ajsaasta@comp.tamu.edu [Cyclotron Institute, Texas A& M University, College Station, TX 77843 (United States); Pollacco, E. [IRFU, CEA Saclay, Gif-sur-Yvette (France); Roeder, B.T.; Spiridon, A.; Daq, M. [Cyclotron Institute, Texas A& M University, College Station, TX 77843 (United States); Trache, L.; Pascovici, G. [National Institute of Physics and Nuclear Engineering, Bucharest-Magurele RO-077125 (Romania); De Oliveira, R. [CERN, Geneva (Switzerland); Rodrigues, M.R.D. [Instituto de Física, Universidade de São Paulo, Caixa Postal 66318, CEP 05314-970, São Paulo, SP (Brazil); Tribble, R.E. [Cyclotron Institute, Texas A& M University, College Station, TX 77843 (United States)

    2016-06-01

    Efficient suppression of β-background is essential for studies of low-energy β-delayed charged particle decays of astrophysical interest. A promising method for such studies has been a micro pattern gas amplifier detector where the sample is implanted into the gas volume and the decays that follow are observed with high gain and signal to noise ratio. An upgraded version of the original AstroBox detector has been built and commissioned at Texas A&M University. Here a description of the new AstroBox2 detector is given, selected results from the commissioning tests are presented, and future perspectives discussed.

  6. Development of a low-cost temperature data monitoring. An upgrade for hot box apparatus

    Science.gov (United States)

    de Rubeis, T.; Nardi, I.; Muttillo, M.

    2017-11-01

    The monitoring phase has gained a fundamental role in the energy efficiency evaluation of a system. Number and typology of the probes depend on the physical quantity to be monitored, and on the size and complexity of the system. Moreover, a measurement equipment should be designed to allow the employment of probes different for number and measured physical quantities. For this reason, a scalable equipment represents a good way for easily carrying out a system monitoring. Proprietary software and high costs characterize instruments of current use, thus limiting the possibilities to realize customized monitoring. In this paper, a temperature measuring instrument, conceived, designed, and realized for real time applications, is presented. The proposed system is based on digital thermometers and on open-source code. A remarkable feature of the instrument is the possibility of acquiring data from a high and variable number of probes (order of hundred), assuring flexibility of the software, since it can be programmed, and low-cost of the hardware components. The contemporary use of multiple temperature probes suggested to apply this instrument for a hot box apparatus, although the software can be set for recording different physical quantities. A hot box compliant with standard EN ISO 8990 should be equipped with several temperature probes to investigate heat exchanges of a specimen wall and thermal field of the chambers. In this work, preliminary tests have been carried out focusing only on the evaluation of the prototypal system’s performance. The tests were realized by comparing different sensors, such as thermocouples and resistance thermometers, traditionally employed in hot box experiments. A preliminary test was realized imposing a dynamic condition with a thermoelectric Peltier cell. Data obtained by digital thermometers DS18B20, compared with the ones of Pt100 probes, show a good correlation. Based on these encouraging results, a further test was carried out

  7. AIM cryocooler developments for HOT detectors

    Science.gov (United States)

    Rühlich, I.; Mai, M.; Withopf, A.; Rosenhagen, C.

    2014-06-01

    Significantly increased FPA temperatures for both Mid Wave and Long Wave IR detectors, i.e. HOT detectors, which have been developed in recent years are now leaving the development phase and are entering real application. HOT detectors allowing to push size weight and power (SWaP) of Integrated Detectors Cooler Assemblies (IDCA's) to a new level. Key component mainly driving achievable weight, volume and power consumption is the cryocooler. AIM cryocooler developments are focused on compact, lightweight linear cryocoolers driven by compact and high efficient digital cooler drive electronics (DCE) to also achieve highest MTTF targets. This technology is using moving magnet driving mechanisms and dual or single piston compressors. Whereas SX030 which was presented at SPIE in 2012 consuming less 3 WDC to operate a typical IDCA at 140K, next smaller cooler SX020 is designed to provide sufficient cooling power at detector temperature above 160K. The cooler weight of less than 200g and a total compressor length of 60mm makes it an ideal solution for all applications with limited weight and power budget, like in handheld applications. For operating a typical 640x512, 15μm MW IR detector the power consumption will be less than 1.5WDC. MTTF for the cooler will be in excess of 30,000h and thus achieving low maintenance cost also in 24/7 applications. The SX020 compressor is based on a single piston design with integrated passive balancer in a new design achieves very low exported vibration in the order of 100mN in the compressor axis. AIM is using a modular approach, allowing the chose between 5 different compressor types for one common Stirling expander. The 6mm expander with a total length of 74mm is now available in a new design that fits into standard dewar bores originally designed for rotary coolers. Also available is a 9mm coldfinger in both versions. In development is an ultra-short expander with around 35mm total length to achieve highest compactness. Technical

  8. CR-39 α track detector and its application in observing of the hot particles in environment

    International Nuclear Information System (INIS)

    Zou Benchuan

    1992-01-01

    CR-39 α track detector is a new α remitting radionuclides plastic detector. It is audio-visual, convenient and economic in the detection of α particle track and the distribution of α emitting radionuclides in environmental samples. CR-39 α track detector is used to observe the hot particles in rock and the hot particles coming from the liquid effluents discharged by spent fuel reprocessing plant in UK in marine environment and got good results

  9. Criticality detector exclusion zone in a spent-fuel hot cell

    International Nuclear Information System (INIS)

    Kim, S.S.; Sterbentz, J.W.

    1999-01-01

    The main purpose of a criticality alarm system (CAS) is to protect personnel by detecting a criticality event (neutron radiation) and actuating an alarm system to initiate emergency response. Inadvertent criticality alarms from noncritical events, such as spurious voltage spikes or intense gamma radiation fields, can produce work cessation and time-consuming and costly event assessments and may result in harm to personnel during an evacuation. It therefore becomes a major concern to ensure that inadvertent or false criticality alarms do not occur or at least are minimized. Minimization of inadvertent criticality alarms due to intense gamma radiation emitted from spent-nuclear-fuel (SNF) elements as opposed to neutron radiation from an actual criticality event is the primary focus of this calculational and experimental study. The Irradiated Fuel Storage Facility (IFSF) located at the Idaho National Engineering and Environmental Laboratory is a government-owned, contractor-operated facility whose mission is to provide safe handling and dry storage for various types of SNFs. Although other fuel types (lower burnup) are stored in the IFSF, it is the high-burnup elements with the associated intense gamma radiation fields that have the potential to inadvertently set off the criticality alarms in the fuel-handling area adjacent to the storage vault. Typically, in the fuel-handling cave or hot cell of the IFSF, the cask lid is removed, and individual fuel elements are extracted from the cask and placed in special storage canisters. It is during the time period when fuel elements are extracted from their casks or when fully loaded canisters are moved in the hot cell that the CAS detectors are exposed to the intense gamma radiation fields from the spent fuel. The neutron detectors positioned in one of the manipulator ports are designed such that fast neutrons from a criticality event are thermalized by a polyethylene moderator, strike the scintillator detector material, and

  10. Search for rare muon and pion decay modes with the Crystal Box detector

    International Nuclear Information System (INIS)

    Hoffman, C.M.; Bolton, R.D.; Bowman, J.D.

    1986-01-01

    New experimental upper limits for the branching ratios of the lepton-family-number nonconserving decays μ + → e + γ and μ + → e + γγ are presented. A new determination of γ, the ratio of pion axial-vector to vector form factors, from radiative pion decay is also reported. These results are from data taken with the Crystal Box detector at LAMPF

  11. Innovations in Los Alamos alpha box design

    International Nuclear Information System (INIS)

    Ledbetter, J.M.; Dowler, K.E.; Cook, J.H.

    1985-01-01

    Destructive examinations of irradiated fuel pins containing plutonium fuel must be performed in shielded hot cells with strict provisions for containing the plutonium. Alpha boxes provide containment for the plutonium, toxic fission products, and other hazardous highly radioactive materials. The alpha box contains windows for viewing and a variety of transfer systems specially designed to allow transfers in and out of the alpha box without spread of the hazardous materials that are contained in the box. Alpha boxes have been in use in the Wing 9 hot cells at Los Alamos National Laboratory for more than 20 years. Features of the newly designed alpha boxes are presented

  12. Search for rare muon and pion decay modes with the crystal box detector

    International Nuclear Information System (INIS)

    Piilonen, L.E.; Bolton, R.D.; Bowman, J.D.

    1986-01-01

    New experiental upper limits for the branching ratios of the lepton-family-number nonconserving decays μ + → e + γ and μ + → e + γγ are presented. A new determination of γ, the ratio of pion axial vector to vector form factors, from radiative pion decay is also reported. These results are from data taken with the Crystal Box detector at LAMPF. 11 refs., 7 figs

  13. Opto-box: Optical modules and mini-crate for ATLAS pixel and IBL detectors

    Directory of Open Access Journals (Sweden)

    Bertsche David

    2016-01-01

    Full Text Available The opto-box is a custom mini-crate for housing optical modules which process and transfer optoelectronic data. Many novel solutions were developed for the custom design and manufacturing. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35×10x8 cm3. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits, were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain. This conference proceeding is in support of the poster presented at the International Conference on New Frontiers in Physics (ICNFP 2015 [1].

  14. Design and performance of modularized NaI(Tl) detectors with rectangular crystal elements: An array of 49 and the Crystal Box

    International Nuclear Information System (INIS)

    Wilson, S.L.; Hofstadter, R.; Hughes, E.B.; Lin, Y.C.; Parks, R.; Rolfe, J.; Bolton, R.D.; Bowman, J.D.; Cooper, M.D.; Hoffman, C.M.; Hogan, G.E.; Mariam, F.G.; Mischke, R.E.; Nagle, D.E.; Piilonen, L.E.; Sandberg, V.D.; Sanders, G.H.; Werbeck, R.; Williams, R.A.; Frank, J.S.; Hallin, A.L.; Matis, H.S.; Sennhauser, U.; Wright, S.C.

    1988-01-01

    An array of 49 NaI(Tl) modules each 20 inch in depth and 2.5 inch x 2.5 inch in cross section has been constructed and its properties, especially energy resolution, explored for positrons in the range 20 MeV - 18 GeV. A subsequent much larger detector, the Crystal Box, has also been constructed from 396 modules of the same cross section, but mostly 12 inch in depth, and operated as a γ-ray and positron detector in a search for rare muon decays. The calibration procedure used for the Crystal Box and its characteristic resolutions in energy, impact point and time are described. (orig.)

  15. Mechanical shielded hot cell

    International Nuclear Information System (INIS)

    Higgy, H.R.; Abdel-Rassoul, A.A.

    1983-01-01

    A plan to erect a mechanical shielded hot cell in the process hall of the Radiochemical Laboratory at Inchas is described. The hot cell is designed for safe handling of spent fuel bundles, from the Inchas reactor, and for dismantling and cutting the fuel rods in preparation for subsequent treatment. The biological shielding allows for the safe handling of a total radioactivity level up to 10,000 MeV-Ci. The hot cell consists of an α-tight stainless-steel box, connected to a γ-shielded SAS, through an air-lock containing a movable carriage. The α-box is tightly connected with six dry-storage cavities for adequate storage of the spent fuel bundles. Both the α-box, with the dry-storage cavities, and the SAS are surrounded by 200-mm thick biological lead shielding. The α-box is equipped with two master-slave manipulators, a lead-glass window, a monorail crane and Padirac and Minirag systems. The SAS is equipped with a lead-glass window, tong manipulator, a shielded pit and a mechanism for the entry of the spent fuel bundle. The hot cell is served by adequate ventilation and monitoring systems. (author)

  16. Superconducting Hot-Electron Submillimeter-Wave Detector

    Science.gov (United States)

    Karasik, Boris; McGrath, William; Leduc, Henry

    2009-01-01

    A superconducting hot-electron bolometer has been built and tested as a prototype of high-sensitivity, rapid-response detectors of submillimeter-wavelength radiation. There are diverse potential applications for such detectors, a few examples being submillimeter spectroscopy for scientific research; detection of leaking gases; detection of explosive, chemical, and biological weapons; and medical imaging. This detector is a superconducting-transition- edge device. Like other such devices, it includes a superconducting bridge that has a low heat capacity and is maintained at a critical temperature (T(sub c)) at the lower end of its superconducting-transition temperature range. Incident photons cause transient increases in electron temperature through the superconducting-transition range, thereby yielding measurable increases in electrical resistance. In this case, T(sub c) = 6 K, which is approximately the upper limit of the operating-temperature range of silicon-based bolometers heretofore used routinely in many laboratories. However, whereas the response speed of a typical silicon- based laboratory bolometer is characterized by a frequency of the order of a kilohertz, the response speed of the present device is much higher characterized by a frequency of the order of 100 MHz. For this or any bolometer, a useful figure of merit that one seeks to minimize is (NEP)(tau exp 1/2), where NEP denotes the noise-equivalent power (NEP) and the response time. This figure of merit depends primarily on the heat capacity and, for a given heat capacity, is approximately invariant. As a consequence of this approximate invariance, in designing a device having a given heat capacity to be more sensitive (to have lower NEP), one must accept longer response time (slower response) or, conversely, in designing it to respond faster, one must accept lower sensitivity. Hence, further, in order to increase both the speed of response and the sensitivity, one must make the device very small in

  17. Ship Detection Using Transfer Learned Single Shot Multi Box Detector

    Directory of Open Access Journals (Sweden)

    Nie Gu-Hong

    2017-01-01

    Full Text Available Ship detection in satellite images is a challenging task. In this paper, we introduce a transfer learned Single Shot MultiBox Detector (SSD for ship detection. To this end, a state-of-the-art object detection model pre-trained from a large number of natural images was transfer learned for ship detection with limited labeled satellite images. To the best of our knowledge, this could be one of the first studies which introduce SSD into ship detection on satellite images. Experiments demonstrated that our method could achieve 87.9% AP at 47 FPS using NVIDIA TITAN X. In comparison with Faster R-CNN, 6.7% AP improvement could be achieved. Effects of the observation resolution has also been studied with the changing input sizes among 300 × 300, 600 × 600 and 900 × 900. It has been noted that the detection accuracy declined sharply with the decreasing resolution that is mainly caused by the missing small ships.

  18. Opto-Box

    CERN Document Server

    Bertsche, David; The ATLAS collaboration; Welch, Steven; Smith, Dale Shane; Che, Siinn; Gan, K.K.; Boyd, George Russell Jr

    2015-01-01

    The opto-box is a custom mini-crate for housing optical modules, which process and transfer optoelectronic data. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35x10x8 cm^3. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits (ASICs), were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain.

  19. Boxing Up a Mini Herd: Art Put to Pasture.

    Science.gov (United States)

    Zimmerman, Midge

    2002-01-01

    Presents an art project for high school students that was inspired by the 1999 "Cows on Parade" exhibition in Chicago (Illinois). Explains that students used old Gateway computer boxes to create their own cows using the box, scissors, and a hot-glue gun. (CMK)

  20. Opto-Box

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00377159; The ATLAS collaboration

    2016-01-01

    The opto-box is a custom mini-crate for housing optical modules, which process and transfer optoelectronic data. Many novel solutions were developed for the custom design and manufacturing. The system tightly integrates electrical, mechanical, and thermal functionality into a small package of size 35x10x8 cm$^{3}$. Special attention was given to ensure proper shielding, grounding, cooling, high reliability, and environmental tolerance. The custom modules, which incorporate Application Specific Integrated Circuits (ASICs), were developed through a cycle of rigorous testing and redesign. In total, fourteen opto-boxes have been installed and loaded with modules on the ATLAS detector. They are currently in operation as part of the LHC run 2 data read-out chain.

  1. Design report for shielded glove box

    International Nuclear Information System (INIS)

    Ku, J. H.; Lee, J. C.; Seo, K. S.; Bang, K. S.; Lee, D. W.; Kim, J. H.; Min, D. K.; Park, S. W.

    1999-05-01

    For the examination of spent fuels and high radioactive specimens using a specially equipped scanning electron microscope, a shielded glove box was designed and constructed at PIE facility of KAERI. This glove box consisted of shielding walls, containment box, lead glasses, manipulators, gloves, ventilation systems, doors, hot-cell specimen cask adapter, etc. It was emphasized that both the easy operation and radiation safety are important factors in the shielded glove box were installed also considered as a important factor to build the basic concept of the assembling. Two sliding doors and one hinge-type door were installed for the easy installation, operation and maintenance of scanning electron microscope. Containment box which confines the radioactive material into the box consisted of reinforced transparent glasses, aluminum frames and stainless steel plate liner. Therefore everything beyond the containment box can be seen through the lead glass which installed at the front shielding wall. All shielding walls and doors were introduced separately into the room and assembled by bolting. (author). 3 refs., 5 tabs., 18 figs

  2. Detector for failed fuel elements

    International Nuclear Information System (INIS)

    Ito, Masaru.

    1979-01-01

    Purpose: To provide automatic monitor for the separation or reactor water and sampling water, in a failed fuel element detector using a sipping chamber. Constitution: A positional detector for the exact mounting of a sipping chamber on a channel box and a level detector for the detection of complete discharge of cooling water in the sipping chamber are provided in the sipping chamber. The positional detector is contacted to the upper end of the channel box and operated when the sipping chamber is correctly mounted to the fuel assemblies. The level detector comprises a float and a limit switch and it is operated when the water in the sipping chamber is discharged by a predetermined amount. Isolation of reactor water and sampling water are automatically monitored by the signal from these two detectors. (Ikeda, J.)

  3. Plutonium glove boxes - metrology and operational states

    International Nuclear Information System (INIS)

    Thyer, A.M.

    2001-01-01

    The main objective was to undertake a literature review in support of NII's ongoing work in improving safety in the nuclear industry to help define suitable standards of cleanliness for plutonium glove boxes. This is to cover the following areas: existing or proposed national/international standards relating to plutonium glove box cleanliness management; practicable metrology options for assessing the plutonium content of glove boxes; any available dose information relating to the operation of modern and 'old design'; current contamination levels of specific significance (i.e. any accepted level in decommissioning/waste terms, typical criticality limits (if available), any box plutonium loadings that are documented with corresponding operator doses etc.); and, techniques for the decontamination of plutonium glove boxes and their relative effectiveness. This should then form the basis of any further development work undertaken by the UK nuclear industry. Main recommendations are as follows: 1) No information could be found in open literature on acceptable levels of contamination in boxes and action levels for cleanup. If these are not available in closed publications the 2) Where possible, the decontamination methods identified should be tested and dose information recorded against each method to allow informed decisions on which is the optimum technique for a particular form of contamination. 3) Consideration should be given to utilisation of metrology options which have the lowest potential for exposure of operators. Preferred options, may be detection from the outside of boxes using hand-held or permanently located radiation detectors, or semi-intrusive methods such as air-ionisation readings which would require one-off installation of detectors in ductwork

  4. Report of the compact detector subgroup

    International Nuclear Information System (INIS)

    Kirkby, J.; Kondo, T.; Olsen, S.L.

    1988-01-01

    This report discusses different detector designs that are being proposed for Superconducting Super Collider experiments. The detectors discussed are: Higgs particle detector, Solid State Box detector, SMART detector, muon detection system, and forward detector. Also discussed are triggering strategies for these detectors, high field solenoids, barium fluoride option for EM calorimetry, radiation damage considerations, and cost estimates

  5. Deep Cuboid Detection: Beyond 2D Bounding Boxes

    OpenAIRE

    Dwibedi, Debidatta; Malisiewicz, Tomasz; Badrinarayanan, Vijay; Rabinovich, Andrew

    2016-01-01

    We present a Deep Cuboid Detector which takes a consumer-quality RGB image of a cluttered scene and localizes all 3D cuboids (box-like objects). Contrary to classical approaches which fit a 3D model from low-level cues like corners, edges, and vanishing points, we propose an end-to-end deep learning system to detect cuboids across many semantic categories (e.g., ovens, shipping boxes, and furniture). We localize cuboids with a 2D bounding box, and simultaneously localize the cuboid's corners,...

  6. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  7. Hot nuclei studies with a 4 π-Neutron detector

    International Nuclear Information System (INIS)

    Galin, J.; Crema, E.; Doubre, H.; Guerreau, D.; Jiang, D.X.; Morjean, M.; Piasecki, E.; Pouthas, J.; Saint-Laurent, F.; Sokolov, A.; Wang, X.D.; Charvet, J.L.; Frehaut, J.; Lott, B.; Magnago, C.; Patin, Y.; Gatty, B.; Jacquet, D.; Lott, B.

    1989-01-01

    When studying the behavior of hot nuclei, the challenge is twofold: how are they formed in nucleus-nucleus collisions and how do they decay Systematic studies have been undertaken at GANIL by bombarding heavy targets (Au, Th) with intermediate energy projectiles (27, 35, 44 and 77 MeV/u Ar and 32 MeV/u Kr). For such neutron rich systems the thermalized energy can be roughly evaluated simply by measuring the multiplicity of evaporated neutrons using a 4 π Gd loaded, liquid scintillator detector. The influence of the bombarding energy and projectile mass on the energy dissipation has been investigated for different exit channels and special emphasis has been put in the study of the most dissipative collisions. The thermal energy, derived by summing the energy removed by both evaporated neutrons and light charged particles is shown to saturate at E * ≅ 650 MeV in the Ar induced reactions between 27 and 77 MeV/u, in good consistency with the predictions of semi-classical Landau-Vlasov calculations

  8. Analysis of the auger recombination rate in P+N-n-N-N HgCdTe detectors for HOT applications

    Science.gov (United States)

    Schuster, J.; Tennant, W. E.; Bellotti, E.; Wijewarnasuriya, P. S.

    2016-05-01

    Infrared (IR) photon detectors must be cryogenically cooled to provide the highest possible performance, usually to temperatures at or below ~ 150K. Such low operating temperatures (Top) impose very stringent requirements on cryogenic coolers. As such, there is a constant push in the industry to engineer new detector architectures that operate at higher temperatures, so called higher operating temperature (HOT) detectors. The ultimate goal for HOT detectors is room temperature operation. While this is not currently possibly for photon detectors, significant increases in Top are nonetheless beneficial in terms of reduced size, weight, power and cost (SWAP-C). The most common HgCdTe IR detector architecture is the P+n heterostructure photodiode (where a capital letter indicates a wide band gap relative to the active layer or "AL"). A variant of this architecture, the P+N-n-N-N heterostructure photodiode, should have a near identical photo-response to the P+n heterostructure, but with significantly lower dark diffusion current. The P+N-n-N-N heterostructure utilizes a very low doped AL, surrounded on both sides by wide-gap layers. The low doping in the AL, allows the AL to be fully depleted, which drastically reduces the Auger recombination rate in that layer. Minimizing the Auger recombination rate reduces the intrinsic dark diffusion current, thereby increasing Top. Note when we use the term "recombination rate" for photodiodes, we are actually referring to the net generation and recombination of minority carriers (and corresponding dark currents) by the Auger process. For these benefits to be realized, these devices must be intrinsically limited and well passivated. The focus of this proceeding is on studying the fundamental physics of the intrinsic dark currents in ideal P+N-n-N-N heterostructures, namely Auger recombination. Due to the complexity of these devices, specifically the presence of multiple heterojunctions, numerical device modeling techniques must be

  9. Performance simulation of BaBar DIRC bar boxes in TORCH

    Science.gov (United States)

    Föhl, K.; Brook, N.; Castillo García, L.; Cussans, D.; Forty, R.; Frei, C.; Gao, R.; Gys, T.; Harnew, N.; Piedigrossi, D.; Rademacker, J.; Ros García, A.; van Dijk, M.

    2017-12-01

    TORCH is a large-area precision time-of-flight detector based on the DIRC principle. The DIRC bar boxes of the BaBar experiment at SLAC could possibly be reused to form a part of the TORCH detector time-of-flight wall area, proposed to provide positive particle identification of low momentum kaons in the LHCb experiment at CERN. For a potential integration of BaBar bar boxes into TORCH, new imaging readout optics are required. From the several designs of readout optics that have been considered, two are used in this paper to study the effect of BaBar bar optical imperfections on the detector reconstruction performance. The kaon-pion separation powers obtained from analysing simulated photon hit patterns show the performance reduction for a BaBar bar of non-square geometry compared to a perfectly rectangular cross section.

  10. Barrier Infrared Detector (BIRD)

    Data.gov (United States)

    National Aeronautics and Space Administration — A recent breakthrough in MWIR detector design, has resulted in a high operating temperature (HOT) barrier infrared detector (BIRD) that is capable of spectral...

  11. submitter Performance simulation of BaBar DIRC bar boxes in TORCH

    CERN Document Server

    Föhl, K; Castillo García, L; Cussans, D; Forty, R; Frei, C; Gao, R; Gys, T; Harnew, N; Piedigrossi, D; Rademacker, J; Ros García, A; van Dijk, M

    2017-01-01

    TORCH is a large-area precision time-of-flight detector based on the DIRC principle. The DIRC bar boxes of the BaBar experiment at SLAC could possibly be reused to form a part of the TORCH detector time-of-flight wall area, proposed to provide positive particle identification of low momentum kaons in the LHCb experiment at CERN. For a potential integration of BaBar bar boxes into TORCH, new imaging readout optics are required. From the several designs of readout optics that have been considered, two are used in this paper to study the effect of BaBar bar optical imperfections on the detector reconstruction performance. The kaon-pion separation powers obtained from analysing simulated photon hit patterns show the performance reduction for a BaBar bar of non-square geometry compared to a perfectly rectangular cross section.

  12. Decommissioning of the Risoe Hot Cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1991-08-01

    Concise descriptions of actions taken in relation to the decommissioning of the hot cell facility at Risoe National Laboratory are presented. The removal of fissile material, removal and decontamination of large cell internals, and of large equipment such as glove boxes and steel boxes, in addition to dose commitments, are explained. Tables illustrating the analysis of smear tests, constants for contamination level examination, contamination and radiation levels after cleaning and total contamination versus measured radiation are included. (AB)

  13. Method and device for monitoring vibration of incore neutron detector guide tube

    International Nuclear Information System (INIS)

    Enomoto, Mitsuhiro; Naito, Norio; Oda, Akira.

    1978-01-01

    Purpose: To easily detect the vibration of an incore neutron detector guide tube and to prevent the occurrence of such accidents that the guide tube comes into contact with the fuel channel box arranged around the periphery thereof to break the channel box. Method: A neutron detector guide tube is disposed within a channel box, and the neutron detector is arranged at the center of the guide tube. Now, when the guide tube vibrates at an inherent number of vibration and a predetermined amplitude, the guide tube moves in the radial direction by the predetermined amplitude part to come into contact with the channel box. Upon this occasion, the detector similarity vibrates, and the output signal is varied by the predetermined neutron flux variation part. This output signal is sent to a comparator through an analyser, and compared with the output signal produced from a device wherein the result analysed at normal time, and the output signal is sent to an alarm device and an indicator, respectively. (Aizawa, K.)

  14. A measurement concept for hot-spot BRDFs from space

    Energy Technology Data Exchange (ETDEWEB)

    Gerstl, S.A.W.

    1996-09-01

    Several concepts for canopy hot-spot measurements from space have been investigated. The most promising involves active illumination and bistatic detection that would allow hot-spot angular distribution (BRDF) measurements from space in a search-light mode. The concept includes a pointable illumination source, such as a laser operating at an atmospheric window wavelength, coupled with a number of high spatial-resolution detectors that are clustered around the illumination source in space, receiving photons nearly coaxial with the reto-reflection direction. Microwave control and command among the satellite cluster would allow orienting the direction of the laser beam as well as the focusing detectors simultaneously so that the coupled system can function like a search light with almost unlimited pointing capabilities. The concept is called the Hot-Spot Search-Light (HSSL) satellite. A nominal satellite altitude of 600 km will allow hot-spot BRDF measurements out to about 18 degrees phase angle. The distributed are taking radiometric measurements of the intensity wings of the hot-spot angular distribution without the need for complex imaging detectors. The system can be operated at night for increased signal-to-noise ratio. This way the hot-spot angular signatures can be quantified and parameterized in sufficient detail to extract the biophysical information content of plant architectures.

  15. A measurement concept for hot-spot BRDFs from space

    Science.gov (United States)

    Gerstl, S.A.W.

    1996-01-01

    Several concepts for canopy hot-spot measurements from space have been investigated. The most promising involves active illumination and bistatic detection that would allow hot-spot angular distribution (BRDF) measurements from space in a search-light mode. The concept includes a pointable illumination source, such as a laser operating at an atmospheric window wavelength, coupled with a number of high spatial-resolution detectors that are clustered around the illumination source in space, receiving photons nearly coaxial with the reto-reflection direction. Microwave control and command among the satellite cluster would allow orienting the direction of the laser beam as well as the focusing detectors simultaneously so that the coupled system can function like a search light with almost unlimited pointing capabilities. The concept is called the Hot-Spot Search-Light (HSSL) satellite. A nominal satellite altitude of 600 km will allow hot-spot BRDF measurements out to about 18 degrees phase angle. The distributed are taking radiometric measurements of the intensity wings of the hot-spot angular distribution without the need for complex imaging detectors. The system can be operated at night for increased signal-to-noise ratio. This way the hot-spot angular signatures can be quantified and parameterized in sufficient detail to extract the biophysical information content of plant architectures.

  16. INDIA: Photon multiplicity detector

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Full text: The team of Indian scientists from Calcutta's Variable Energy Cyclotron Centre, Bhubaneswar Institute of Physics, Panjab (Chandigarh), Rajasthan (Jaipur) and Jammu in collaboration with GSI Darmstadt have contributed a large and highly granular preshower photon multiplicity detector (PMD) for the WA98 experiment at the CERN SPS proton synchrotron. This experiment studies high energy collisions of lead ions and will measure both charged particle and photon multiplicity in a large overlap region. The motivation for measuring photon multiplicity in ultra-relativistic heavy ion collisions stems from theoretical predictions of changes in the relative production of photons and charged particles in the phase transition of hadronic matter to quarkgluon plasma and its subsequent hadronization. The photon multiplicity detector consists of a matrix of scintillator pads placed in light-tight boxes and mounted behind the lead converter plates. The light from the scintillator pads is transported to the readout system using wavelength shifting (WLS) fibres. Developing on the team's earlier experience with a smaller version for the WA93 experiment (September 1991, page 16), several modifications were incorporated to improve light collection and transport. Use of improved WLS fibres, short WLS pieces to minimize self-absorption, and thermal splicing with long clear fibres were some of the important changes incorporated. Tests showed signficantly improved light collection. The scintillator pads were fabricated at all the five collaborating centres in India and the complicated assembly in the detector box modules carried out at the Variable Energy Cyclotron Centre, Calcutta. More than 400 lead converter plates were machined in Calcutta to rigorous tolerances of 0.2 mm. The assembled detector box modules and lead plates were shipped to CERN in spring 1994 for tests and installation. The WA98 PMD consists of over 50,000 scintillator pads of sizes varying from 15 to

  17. INDIA: Photon multiplicity detector

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-01-15

    Full text: The team of Indian scientists from Calcutta's Variable Energy Cyclotron Centre, Bhubaneswar Institute of Physics, Panjab (Chandigarh), Rajasthan (Jaipur) and Jammu in collaboration with GSI Darmstadt have contributed a large and highly granular preshower photon multiplicity detector (PMD) for the WA98 experiment at the CERN SPS proton synchrotron. This experiment studies high energy collisions of lead ions and will measure both charged particle and photon multiplicity in a large overlap region. The motivation for measuring photon multiplicity in ultra-relativistic heavy ion collisions stems from theoretical predictions of changes in the relative production of photons and charged particles in the phase transition of hadronic matter to quarkgluon plasma and its subsequent hadronization. The photon multiplicity detector consists of a matrix of scintillator pads placed in light-tight boxes and mounted behind the lead converter plates. The light from the scintillator pads is transported to the readout system using wavelength shifting (WLS) fibres. Developing on the team's earlier experience with a smaller version for the WA93 experiment (September 1991, page 16), several modifications were incorporated to improve light collection and transport. Use of improved WLS fibres, short WLS pieces to minimize self-absorption, and thermal splicing with long clear fibres were some of the important changes incorporated. Tests showed signficantly improved light collection. The scintillator pads were fabricated at all the five collaborating centres in India and the complicated assembly in the detector box modules carried out at the Variable Energy Cyclotron Centre, Calcutta. More than 400 lead converter plates were machined in Calcutta to rigorous tolerances of 0.2 mm. The assembled detector box modules and lead plates were shipped to CERN in spring 1994 for tests and installation. The WA98 PMD consists of over 50,000 scintillator pads of sizes varying from 15 to 25 mm

  18. Attenuation correction factors for cylindrical, disc and box geometry

    International Nuclear Information System (INIS)

    Agarwal, Chhavi; Poi, Sanhita; Mhatre, Amol; Goswami, A.; Gathibandhe, M.

    2009-01-01

    In the present study, attenuation correction factors have been experimentally determined for samples having cylindrical, disc and box geometry and compared with the attenuation correction factors calculated by Hybrid Monte Carlo (HMC) method [ C. Agarwal, S. Poi, A. Goswami, M. Gathibandhe, R.A. Agrawal, Nucl. Instr. and. Meth. A 597 (2008) 198] and with the near-field and far-field formulations available in literature. It has been observed that the near-field formulae, although said to be applicable at close sample-detector geometry, does not work at very close sample-detector configuration. The advantage of the HMC method is that it is found to be valid for all sample-detector geometries.

  19. Monitoring Instrument for X-Ray Box

    CERN Document Server

    Cifuentes Ospina, Alberto; Kuehn, Susanne; Schaepe, Steffen; CERN. Geneva. EP Department

    2017-01-01

    A humidity and temperature readout instrument has been designed and implemented in order to monitor the X-Ray Box used for testing the silicon detectors prototypes of the ITk. The sensors are connected to an Arduino Mega board equipped with 16 analog inputs and a serial port to a computer. A user-friendly software has been also designed in order to give an easy access to all measurements.

  20. Terahertz detectors using hot-electrons in superconducting films

    Energy Technology Data Exchange (ETDEWEB)

    Semenov, A. [DLR, Inst. of Planetary Research, Berlin (Germany)

    2007-07-01

    Recently the terahertz gap has been recognized as a prospective spectral range for radioastronomy as well as for material and security studies. Implementation of terahertz technology in these fields requires further improvement of instruments and their major subcomponents. Physical phenomena associated with the local and homogeneous non-equilibrium electron sates in thin superconducting films offer numerous possibilities for the development of terahertz and infrared detectors. Depending on the nature of the resistive state and the operation regime, a variety of detector can be realized. They are e.g. direct bolometric or kinetic inductance detectors, heterodyne mixers or photon counters. Operation principles and physical limitations of these devices will be discussed. Two examples of the detector development made in cooperation between the German Aerospace Center, the University of Karlsruhe and PTB, Berlin will be presented. The energy resolving single-photon detector with an almost fundamentally limited energy resolution of 0.6 eV at 6.5 K for photons with wavelengths from 400 nm to 2500 nm and the heterodyne mixer quasioptically coupled to radiation in the frequency range from 0.8 THz to 5 THz and providing a noise temperature of less then ten times the quantum limit. The mixers will be implemented in the terahertz radar for security screening (TERASEC) and in the heterodyne receiver of the stratospheric observatory SOFIA. (orig.)

  1. The LiC detector toy program

    International Nuclear Information System (INIS)

    Regler, Meinhard; Valentan, Manfred; Fruehwirth, Rudolf

    2007-01-01

    This note describes the 'LiC Detector Toy' ('LiC' for Linear Collider) software tool which has been developed for detector design studies, aiming at investigating the resolution of reconstructed track parameters for the purpose of comparing and optimizing various detector setups. It consists of a simplified simulation of the detector measurements, taking into account multiple scattering, followed by full single track reconstruction using the Kalman filter. The tool is written in MATLAB and may be installed on a laptop. It can easily be used as a black-box tool by non-experts, but also adapted to individual needs

  2. Design of nanophotonic, hot-electron solar-blind ultraviolet detectors with a metal-oxide-semiconductor structure

    International Nuclear Information System (INIS)

    Wang, Zhiyuan; Wang, Xiaoxin; Liu, Jifeng

    2014-01-01

    Solar-blind ultraviolet (UV) detection refers to photon detection specifically in the wavelength range of 200 nm–320 nm. Without background noises from solar radiation, it has broad applications from homeland security to environmental monitoring. The most commonly used solid state devices for this application are wide band gap (WBG) semiconductor photodetectors (Eg > 3.5 eV). However, WBG semiconductors are difficult to grow and integrate with Si readout integrated circuits (ROICs). In this paper, we design a nanophotonic metal-oxide-semiconductor structure on Si for solar-blind UV detectors. Instead of using semiconductors as the active absorber, we use Sn nano-grating structures to absorb UV photons and generate hot electrons for internal photoemission across the Sn/SiO 2 interfacial barrier, thereby generating photocurrent between the metal and the n-type Si region upon UV excitation. Moreover, the transported hot electron has an excess kinetic energy >3 eV, large enough to induce impact ionization and generate another free electron in the conduction band of n-Si. This process doubles the quantum efficiency. On the other hand, the large metal/oxide interfacial energy barrier (>3.5 eV) also enables solar-blind UV detection by blocking the less energetic electrons excited by visible photons. With optimized design, ∼75% UV absorption and hot electron excitation can be achieved within the mean free path of ∼20 nm from the metal/oxide interface. This feature greatly enhances hot electron transport across the interfacial barrier to generate photocurrent. The simple geometry of the Sn nano-gratings and the MOS structure make it easy to fabricate and integrate with Si ROICs compared to existing solar-blind UV detection schemes. The presented device structure also breaks through the conventional notion that photon absorption by metal is always a loss in solid-state photodetectors, and it can potentially be extended to other active metal photonic devices. (paper)

  3. Study on partial overheat of the isolated phase busbar outlet box in Qinshan NPP phase Ⅱ

    International Nuclear Information System (INIS)

    Tang Fangxuan; Zhang Jian; Zeng Limin; Bao Yanxing; Zhang Lie; Yang Yuemin

    2013-01-01

    This paper recommended the structure of the isolated phase busbar outlet box installed in Qinshan II. The study on partial overheat of the outlet box shows that the ultimate causes are the loss of concentrated eddy current and short of cooling. So the improvement principles of 'distributing eddy current, cutting off inductive circle current and strengthening of ventilation' were determined. A new structure test outlet box was designed and manufactured, and the temperature rising experiment was carried out. Some alterations were made in the new structure outlet box, e.g. isolating materials were added between side plates of the upper outlet box, and also between the upper and lower outlet box. Two cooling blowers were added to the upper outlet box. After putting into operation, the hot-spot temperature of the new outlet box was greatly lowered down. Thus the operation environment was improved, and the operation safety ensured. It can be useful references for analyzing and dealing with similar problems. (authors)

  4. Development and Production of Array Barrier Detectors at SCD

    Science.gov (United States)

    Klipstein, P. C.; Avnon, E.; Benny, Y.; Berkowicz, E.; Cohen, Y.; Dobromislin, R.; Fraenkel, R.; Gershon, G.; Glozman, A.; Hojman, E.; Ilan, E.; Karni, Y.; Klin, O.; Kodriano, Y.; Krasovitsky, L.; Langof, L.; Lukomsky, I.; Nevo, I.; Nitzani, M.; Pivnik, I.; Rappaport, N.; Rosenberg, O.; Shtrichman, I.; Shkedy, L.; Snapi, N.; Talmor, R.; Tessler, R.; Weiss, E.; Tuito, A.

    2017-09-01

    XB n or XB p barrier detectors exhibit diffusion-limited dark currents comparable with mercury cadmium telluride Rule-07 and high quantum efficiencies. In 2011, SemiConductor Devices (SCD) introduced "HOT Pelican D", a 640 × 512/15- μm pitch InAsSb/AlSbAs XB n mid-wave infrared (MWIR) detector with a 4.2- μm cut-off and an operating temperature of ˜150 K. Its low power (˜3 W), high pixel operability (>99.5%) and long mean time to failure make HOT Pelican D a highly reliable integrated detector-cooler product with a low size, weight and power. More recently, "HOT Hercules" was launched with a 1280 × 1024/15- μm format and similar advantages. A 3-megapixel, 10- μm pitch version ("HOT Blackbird") is currently completing development. For long-wave infrared applications, SCD's 640 × 512/15- μm pitch "Pelican-D LW" XB p type II superlattice (T2SL) detector has a ˜9.3- μm cut-off wavelength. The detector contains InAs/GaSb and InAs/AlSb T2SLs, and is fabricated into focal plane array (FPA) detectors using standard production processes including hybridization to a digital silicon read-out integrated circuit (ROIC), glue underfill and substrate thinning. The ROIC has been designed so that the complete detector closely follows the interfaces of SCD's MWIR Pelican-D detector family. The Pelican-D LW FPA has a quantum efficiency of ˜50%, and operates at 77 K with a pixel operability of >99% and noise equivalent temperature difference of 13 mK at 30 Hz and F/2.7.

  5. Optimizing moderation of He-3 neutron detectors for shielded fission sources

    Energy Technology Data Exchange (ETDEWEB)

    Rees, Lawrence B., E-mail: Lawrence_Rees@byu.edu [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States); Czirr, J. Bart, E-mail: czirr@juno.com [Department of Physics and Astronomy, Brigham Young University, Provo, UT 84602 (United States)

    2012-11-01

    The response of a {sup 3}He neutron detector is highly dependent on the amount of moderator incorporated into the detector system. If there is too little moderation, neutrons will not react with the {sup 3}He. If there is too much moderation, neutrons will not reach the {sup 3}He. In applications for portal or border monitors where {sup 3}He detectors are used to interdict illicit importation of plutonium, the fission source is always shielded to some extent. Since the energy distribution of neutrons emitted from the source depends on the amount and type of shielding present, the optimum placement of moderating material around {sup 3}He tubes is a function of shielding. In this paper, we use Monte Carlo techniques to model the response of {sup 3}He tubes placed in polyethylene boxes for moderation. To model the shielded fission neutron source, we use a point {sup 252}Cf source placed in the center of polyethylene spheres of varying radius. Detector efficiency as a function of box geometry and shielding is explored. We find that increasing the amount of moderator behind and to the sides of the detector generally improves the detector response, but that incremental benefits are minimal if the thickness of the polyethylene moderator is greater than about 5-7 cm. The thickness of the moderator in front of the {sup 3}He tubes, however, is very important. For bare sources, about 4-5 cm of moderator is optimum, but as the shielding increases, the optimum thickness of this moderator decreases to 0.5-1 cm. Similar conclusions can be applied to polyethylene boxes employing two {sup 3}He tubes. Two-tube boxes with front moderators of non-uniform thickness may be useful for detecting neutrons over a wide energy range.

  6. Manufacturing method of fuel assembly and channel box for the fuel assembly

    International Nuclear Information System (INIS)

    Fujieda, Tadashi; Inagaki, Masatoshi; Takase, Iwao; Nishino, Yoshitaka; Yamashita, Jun-ichi; Yamanaka, Akihiro; Ito, Ken-ichi; Nakajima, Junjiro; Seto, Takehiro.

    1998-01-01

    An MOX fuel assembly to be used for a BWR type reactor comprises a channel box, a great number of fuel rod bundles and a water rod. BP members incorporated with a burnable neutron absorbing poison (BP) are buried in the vicinity of corners of four sides of the channel box in the longitudinal direction. The channel box is formed by fitting the BP members in concaves formed in the longitudinal direction of zircaloy plates, laminating other zircaloy plates and welding the seams. Then, hot rolling, cold rolling and annealing are conducted to form them into a single plate. Integrated two single plates after bending treatment are abutted and welded, and heat-treatment is applied to complete the channel box. With such a constitution, since the BP member is not brought into contact with reactor water directly, crevice corrosion or galvanic corrosion can be prevented. (I.N.)

  7. Mechanical analysis of an assembly box with honeycomb structure

    International Nuclear Information System (INIS)

    Herbell, Heiko; Himmel, Steffen; Schulenberg, Thomas

    2008-01-01

    Fuel assembly concepts for supercritical water cooled reactors have often been designed with assembly and moderator boxes to provide additional moderator water in the core in case of higher coolant temperatures. The fuel assembly considered here has been designed for the High Performance Light Water Reactor (HPLWR) with three succeeding heat up steps, one evaporator and two superheater steps. The high coolant pressure drop of such a core design causes, however, a higher pressure difference across the box walls than those typically occurring in boiling water reactors. Hot, superheated steam conditions, on the other hand, require thermally insulated box walls rather than solid box walls to reduce heating of the moderator water. In this paper an innovative design for moderator- and assembly boxes is investigated which consists of an alumina filled stainless steel honeycomb structure, built as a sandwich design between two stainless steel liners. The liners in contact with the colder moderator water are perforated to lower the pressure load on the honeycomb structure. As a consequence, the alumina will be soaked with supercritical water causing stagnant flow conditions in the honeycomb cells. In comparison to solid box walls, the use of the presented design can provide the same stiffness but with a drastic reduction of structural material and thus less neutron absorption. Finite Element Analyses are used to verify the required stiffness, to identify stress concentrations, and to optimize the design. (author)

  8. Investigation on processing technology for tritiated water in glove box

    International Nuclear Information System (INIS)

    Luo Deli; Meng Daqiao

    2002-01-01

    A 0.5 nm molecular sieve absorption column and a hot decomposing magnesium bed was found to be one of the effective means to collect and decompose HTO in glove box atmosphere. The absorption characteristics of the 0.5 nm molecular sieve column and water decomposing characteristics of the hot Mg bed were obtained. The results showed that the column absorbs water vapour from air with efficiency up to 99.99%. Water in tested gases was between 3.4 x 10 3 to 4.2 x 10 3 μg·g -1 and the total water absorbed on the column was up to 162 g, under this condition no water was detected in output gases. Using the hot magnesium bed more than 99.9% desorption water from the column was decomposed

  9. DNA Radiation Environments Program: Fall 1989 2-meter box experiments and analysis

    International Nuclear Information System (INIS)

    Santoro, R.T.

    1991-05-01

    This effort, sponsored by the Defense Nuclear Agency under the Radiation Environments Program, was carried out to obtain measured data for benchmarking MASH, the Monte Carlo Adjoint Code System. MASH was developed to replace the Vehicle Code System, VCS, that has been used by the Department of Defense and NATO for calculating neutron and gamma-ray radiation fields and shielding protection factors inside armored vehicles and structures from nuclear weapon radiation. Free-field data were obtained at distances of 170- and 400-meters from the APR while in-box measurements were made at 400 meters only. The box, included to obtain neutron and gamma-ray reduction factors, was a 2-meter cube configuration having 0.1016-m-thick steel walls. Calculated data were obtained using MASH by analysts from the Oak Ridge National Laboratory and Science Applications International Corporation. Calculated (C) results were compared with experimental (E) data in terms of C/E ratios. Free-field and in-box neutron kerma generally agreed within ±20%, although some C/E comparisons fell outside this range depending upon the detector against which the calculated data were compared. For those cases where the C/E ratio is marginal or unacceptable, problems in the detector systems were acknowledged to be principal cause of the discrepancy. Generally poor agreement (∼25-35%) was achieved among the C/E ratios for the free-field gamma-ray kerma at the 170- and 400-m locations while excellent (10%, or better) C/E values were obtained for the in-box conditions. The discrepancy for the free-field comparison was attributed to the failure by the analysts to include a tree line adjacent to the measurement site in the calculational geometry. C/E values for the neutron and gamma-ray reduction factors ranged from 1% to 23% depending on the detector. 4 refs., 2 figs., 14 tabs

  10. Design of an ionization diffusion chamber detector

    International Nuclear Information System (INIS)

    Sugiarto, S.

    1976-01-01

    Prototype of an Ionization Diffusion Chamber detector has been made. It is a silindrical glass, 20 cm in diameter, 13,5 cm in height, air gas filled, operated at room pressure and room temperature at the top of this instrument while for the box temperature dry ice (CO 2 solid) temperature is used. This detector is ready for seeing alpha and beta particle tracks. (author)

  11. [The design of heat dissipation of the field low temperature box for storage and transportation].

    Science.gov (United States)

    Wei, Jiancang; Suin, Jianjun; Wu, Jian

    2013-02-01

    Because of the compact structure of the field low temperature box for storage and transportation, which is due to the same small space where the compressor, the condenser, the control circuit, the battery and the power supply device are all placed in, the design for heat dissipation and ventilation is of critical importance for the stability and reliability of the box. Several design schemes of the heat dissipation design of the box were simulated using the FLOEFD hot fluid analysis software in this study. Different distributions of the temperature field in every design scheme were constructed intimately in the present study. It is well concluded that according to the result of the simulation analysis, the optimal heat dissipation design is decent for the field low temperature box for storage and transportation, and the box can operate smoothly for a long time using the results of the design.

  12. Decontamination of two filter boxes after a fire

    International Nuclear Information System (INIS)

    Cerre, P.; Mestre, E.; Lafitte, T.

    1961-01-01

    As a primary filter of the venting system caught fire in a hot cell of the Laboratory of Examination of Irradiated Fuels, this filter (as well as the secondary filter) has been removed, wrapped in polyvinyl sheets, and transported into the decontamination station. The authors report the details of the handling and decontamination operations: modifications to the station arrangement, measures of radiation protection, decontamination and measurements, observations made when disassembling the filter and filter-boxes [fr

  13. Terahertz hot electron bolometer waveguide mixers for GREAT

    OpenAIRE

    Pütz, P.; Honingh, C. E.; Jacobs, K.; Justen, M.; Schultz, M.; Stutzki, J.

    2012-01-01

    Supplementing the publications based on the first-light observations with the German Receiver for Astronomy at Terahertz frequencies (GREAT) on SOFIA, we present background information on the underlying heterodyne detector technology. We describe the superconducting hot electron bolometer (HEB) detectors that are used as frequency mixers in the L1 (1400 GHz), L2 (1900 GHz), and M (2500 GHz) channels of GREAT. Measured performance of the detectors is presented and background information on the...

  14. Prediction and experimental validation of stagnation temperature attained by a solar cooker of hot box type

    Energy Technology Data Exchange (ETDEWEB)

    Narasimha Rao, A. V; Srikrishna, D. V. N [Warangal (India)

    2000-07-01

    A hot box type solar cooker, having double glass covers and a plane mirror reflector, is tested for stagnation temperature. A computer code is developed based on the analytical model proposed by Vaishya et. al. The global and beam components of solar radiation measured at Warangal are made use to predict the stagnation temperature of the cooker. The observed values of stagnation temperature at Warangal are compared with those of predicted values. A good agreement of the measured and observed values of the stagnation temperature is observed during the afternoon period. The lag in the observed values during the forenoon may be due to thermal inertia of the cooker. [Spanish] Se probo una estufa solar de tipo caja caliente con cubiertas dobles de vidrio y un espejo reflector plano para medir la temperatura de estancamiento. Se desarrollo un codigo de computacion basado en el modelo analitico propuesto por Vaishya et. al. Los componentes de la radiacion solar globales y de rayo medidos en Warangal se usan para predecir la temperatura de estancamiento de la estufa. Los valores observados de la temperatura de estancamiento en Warangal se comparan con los valores predichos. Se aprecia una buena concidencia de los valores medidos y observados de la temperatura de estancamiento durante el periodo de la tarde. El retraso de los valores observados durante la manana puede ser debido a la inercia termica de la estufa.

  15. Component and system tests of the SLD Cerenkov Ring Imaging Detector

    International Nuclear Information System (INIS)

    Antilogus, P.; Bird, F.; Aston, D.; Dasu, S.; Dunwoodie, W.; Hallewell, G.; Kawahara, H.; Kwon, Y.; Leith, D.; Nagamine, T.; Pavel, T.; Muller, D.; Williams, S.; Bienz, T.; Dolinsky, S.; Solodov, E.; Coyle, P.; Cavalli-Sforza, M.; Coyne, D.; Gagnon, P.; Liu, X.; Williams, D.A.

    1990-01-01

    The components of the SLD barrel Cerenkov Ring Imaging Detector (CRID) are now built and are being installed. This paper reports on tests of these components, including tests of the fiber optic calibration system, detailed studies of electron drift paths on production drift boxes and detectors, tests of the dynamic gating system and its effect on drift path distortions due to space-charge, and a measurement of the electron lifetime in a production drift box. In addition, the authors report on the UV transmission of recirculated liquid freon and on the effects of CRID construction materials on electron lifetime

  16. Component and system tests of the SLD Cerenkov Ring Imaging Detector

    International Nuclear Information System (INIS)

    Antilogus, P.; Aston, D.; Bienz, T.; Bird, F.; Dasu, S.; Dolinsky, S.; Dunwoodie, W.; Hallewell, G.; Kawahara, H.; Kwon, Y.; Leith, D.; Muller, D.; Nagamine, T.; Pavel, T.; Ratcliff, B.; Rensing, P.; Schultz, D.; Shapiro, S.; Simopoulos, C.; Solodov, E.; Toge, N.; Va'vra, J.; Williams, S.; Cavalli-Sforza, M.; Coyle, P.; Coyne, D.; Gagnon, P.; Liu, X.; Williams, D.A.; Whitaker, J.S.; Wilson, R.J.; Bean, A.; Caldwell, D.; Duboscq, J.; Huber, J.; Lu, A.; Mathys, L.; McHugh, S.; Witherell, M.; Yellin, S.; D'Oliveira, A.; Johnson, R.A.; Martinez, J.L.; Meadows, B.; Nussbaum, M.; Santha, A.K.S.; Shoup, A.; Stockdale, I.; Baird, K.; Jacques, P.; Kalelkar, M.; Plano, R.; Stamer, P.; Word, G.; Abe, K.; Hasegawa, K.; Suekane, F.; Yuta, H.

    1991-02-01

    The components of the SLD barrel Cerenkov Ring Imaging Detector (CRID) are now built and are being installed. We report on tests of these, including tests of the fiber optic calibration system, detailed studies of electron drift paths on production drift boxes and detectors, tests of the dynamic gating system and its effect on drift path distortions due to space-charge, and a measurement of the electron lifetime in a production drift box. In addition, we report on the UV transmission of recirculated liquid C 6 F 14 and on the effects of CRID construction materials on electron lifetime. 9 refs., 11 figs

  17. Component and system tests of the SLD Cerenkov Ring Imaging Detector

    International Nuclear Information System (INIS)

    Antilogus, P.; Aston, D.; Bienz, T.; Bird, F.; Dasu, S.; Dolinsky, S.; Dunwoodie, W.; Hallewell, G.; Kawahara, H.; Kwon, Y.; Leith, D.; Muller, D.; Nagamine, T.; Pavel, T.; Ratcliff, B.; Rensing, P.; Schultz, D.; Shapiro, S.; Simopoulos, C.; Solodov, E.; Toge, N.; Va'vra, J.; Williams, S.; Cavalli-Sforza, M.; Coyle, P.; Coyne, D.; Gagnon, P.; Liu, X.; Williams, D.A.; Whitaker, J.S.; Wilson, R.J.; Bean, A.; Caldwell, D.; Duboscq, J.; Huber, J.; Lu, A.; Mathys, L.; McHugh, S.; Witherell, M.; Yellin, S.; d'Oliveira, A.; Johnson, R.A.; Martinez, J.; Meadows, B.; Nussbaum, M.; Santha, A.K.S.; Shoup, A.; Stockdale, I.; Jacques, P.; Kalelkar, M.; Plano, R.; Stamer, P.; Abe, K.; Hasegawa, K.; Suekane, F.; Yuta, H.

    1990-10-01

    The components of the SLD barrel Cerenkov Ring Imaging Detector (CRID) are now built and are being installed. We report on tests of these components, including tests of the fiber optic calibration system, detailed studies of electron drift paths on production drift boxes and detectors, tests of the dynamic gating systems and its effect on drift path distortions due to space-charge, and a measurement of the electron lifetime in a production drift box. In addition, we report on the UV transmission of recirculated liquid freon and on the effects of CRID construction materials on electron lifetime. 16 refs., 12 figs

  18. Alpha contamination assessment for D ampersand D activities: Monitoring inside glove boxes and vessels

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Bolton, R.D.; Conaway, J.G.; MacArthur, D.W.

    1996-02-01

    We have developed a new approach to glove box monitoring that involves drawing air out of one glove port through a detection grid that collects ions created in the air inside the glove box by ionizing radiation, especially alpha radiation. The charge deposited on the detection grid by the ions is measured with a sensitive electrometer. The air can be circulated back to the glove box through the other glove port, preventing contamination from leaving the glove box and detector system. Initial experiments using a mock-up constructed of sheet metal indicate that this technology provides the measurement technique needed to perform a defensible, non-invasive measurement of alpha contamination inside glove boxes destined for waste disposal. This can result in an enormous cost savings if a given glove box can be shown to fall into the catagory of Low-Level Waste rather than Trans-Uranic Waste. Considering that hundreds of glove boxes contaminated with plutonium will be taken out of service at various nuclear facilities over the next few years, the potential cost savings associated with disposal as LLW rather than TRU waste are substantial

  19. Cryostat for an well logging probe using a semiconductor detector

    International Nuclear Information System (INIS)

    Tapphorn, R.M.

    1978-01-01

    This invention proposes to construct an well logging tool of the type comprising a semiconductor radiation detector devoid of the defects usually observed. This aim is attained by means of a cryostat to cool a semiconductor radiation detector in a restricted space where the temperature is high. It includes a long box dimensioned to pass through a bore hole, a cryogenic chamber housed in the box, a vacuum chamber thermally insulating the cryogenic chamber and placed around it, a semiconductor radiation detector housed in the vacuum chamber in thermal contact with the cryogenic chamber and an active vacuum pump fitted in the box and connected to the vacuum chamber to maintain a vacuum in it. In an improved version, the vacuum pump is fitted outside the cryostat so that it operates independently of the temperature conditions in the cryostat. If the pump needs to be cooled to reduce the gas discharge, it can be fitted inside the cryostat and connected to the cryogenic chamber or a second cryostat can also be provided to cool the pump. The vacuum pump is designed to maintain the vacuum in the thermal insulation vacuum chamber at a desired figure, preferably 10 -4 Torr or under, in order to preserve the integrity of the thermal insulation layer around the cryogenic chamber and thereby extending the efficient operating period of the detector. The cryogenic material used is preferably of fusion resistant type such as Freon 22 [fr

  20. Estimation method for volumes of hot spots created by heavy ions

    International Nuclear Information System (INIS)

    Kanno, Ikuo; Kanazawa, Satoshi; Kajii, Yuji

    1999-01-01

    As a ratio of volumes of hot spots to cones, which have the same lengths and bottom radii with the ones of hot spots, a simple and convenient method for estimating the volumes of hot spots is described. This calculation method is useful for the study of damage producing mechanism in hot spots, and is also convenient for the estimation of the electron-hole densities in plasma columns created by heavy ions in semiconductor detectors. (author)

  1. Hot particles in industrial waste and mining tailings

    CERN Document Server

    Selchau-Hansen, K; Freyer, K; Treutler, C; Enge, W

    1999-01-01

    Industrial waste was studied concerning its radioactive pollution. Using known properties of the solid state nuclear track detector CR-39 we found among a high concentration of more or less homogeneously distributed single alpha-tracks discrete spots of very high enrichments of alpha-particles created by so called hot particles. We will report about the alpha-activity, the concentration of hot particles and about their ability to be air borne.

  2. Recent progress in the development of MCT hot detectors

    Science.gov (United States)

    Wollrab, R.; Schirmacher, W.; Schallenberg, T.; Lutz, H.; Wendler, J.; Haiml, M.; Ziegler, J.

    2017-11-01

    To push HOT-performance, AIMs existing n-on-p technology has been improved by introducing Gold as an acceptor and reducing its concentration to the lower 1015/cm3 range as well as by optimizing the passivation process. This results in a substantial reduction in dark current density, a prerequisite for HOT operation. Recent dark current data are compared to ones previously obtained as well as to Tennant`s Rule07 [1], a generally accepted bench mark in this context. Furthermore, we present electro-optical parameters obtained in the temperature range from 120 K to 170 K on resulting FPAs with 640x512 pixels, a pitch of 15 μm and a typical (80 K) cutoff wavelength of 5.1 μm.

  3. A mower detector to judge soil sorting

    International Nuclear Information System (INIS)

    Bramlitt, E.T.; Johnson, N.R.

    1995-01-01

    Thermo Nuclear Services (TNS) has developed a mower detector as an inexpensive and fast means for deciding potential value of soil sorting for cleanup. It is a shielded detector box on wheels pushed over the ground (as a person mows grass) at 30 ft/min with gamma-ray counts recorded every 0.25 sec. It mirror images detection by the TNS transportable sorter system which conveys soil at 30 ft/min and toggles a gate to send soil on separate paths based on counts. The mower detector shows if contamination is variable and suitable for sorting, and by unique calibration sources, it indicates detection sensitivity. The mower detector has been used to characterize some soil at Department of Energy sites in New Jersey and South Carolina

  4. A mower detector to judge soil sorting

    Energy Technology Data Exchange (ETDEWEB)

    Bramlitt, E.T.; Johnson, N.R. [Thermo Nuclear Services, Inc., Albuquerque, NM (United States)

    1995-12-31

    Thermo Nuclear Services (TNS) has developed a mower detector as an inexpensive and fast means for deciding potential value of soil sorting for cleanup. It is a shielded detector box on wheels pushed over the ground (as a person mows grass) at 30 ft/min with gamma-ray counts recorded every 0.25 sec. It mirror images detection by the TNS transportable sorter system which conveys soil at 30 ft/min and toggles a gate to send soil on separate paths based on counts. The mower detector shows if contamination is variable and suitable for sorting, and by unique calibration sources, it indicates detection sensitivity. The mower detector has been used to characterize some soil at Department of Energy sites in New Jersey and South Carolina.

  5. Introduction of hot cell facility in research center Rez - Poster

    International Nuclear Information System (INIS)

    Petrickova, A.; Srba, O.; Miklos, M.; Svoboda, P.

    2015-01-01

    This poster presents the hot cell facility which is being constructed as part of the SUSEN project at the Rez research center (Czech Republic). Within this project a new complex of 10 hot cells and one semi-hot cell will be built. There will be 8 gamma hot cells and 2 alpha hot cells. In each hot cell a hermetic, removable box made of stainless steel will home different type of devices. The hot cells and semi hot cell will be equipped with devices for processing samples (cutting, welding, drilling, machining) as well as equipment for testing (sample preparation area, stress testing machine, fatigue machine, electromechanical creep machine, high frequency resonance pulsator...) and equipment for studying material microstructure (nano-indenter with nano-scratch tester and scanning electron microscope). An autoclave with water loop, installed in a cell will allow mechanical testing in control environment of water, pressure and temperature. A scheme shows the equipment of each cell. This hot laboratory will be able to cover all the process to study radioactive materials: receiving the material, the preparation of the samples, mechanical testing and microstructure observation. Our hot cells will be close to the research nuclear reactor LVR-15 and new irradiation facility (high irradiation by cobalt source) is planned to be built within the SUSEN project

  6. Hot laboratory design on the basis of standardized components

    International Nuclear Information System (INIS)

    Cadrot, J.

    1976-01-01

    The paper describes the principal effects on hot laboratory design brought about over the last 15 years by the use of standardized components developed jointly with the CEA and the industrial associates of AFINE. After a rapid survey of the various advantages of standardization, the author turns to the specific case of a laboratory producing mixed plutonium and uranium oxide fuels, giving a brief description of the glove-boxes and ancillary equipment. He then deals with the design of an isotope production laboratory. The basic component is the DR 200 standard cell, which permits the civil engineering work to be effected on modular principles. Use of a safety-flow pressure regulating valve makes possible pneumatic automation of the production-cell internals. A substantial gain in output is the result. In the next section the paper refers to a pilot facility for irradiated fuel studies, and describes the components used, which require taking into account the high activities and intense radiations encountered in studies of this type. The author then demonstrates the flexibility with which standardized components can be adapted to different uses, thus solving many distinct problems, an example of which is represented by a semi-hot box for handling up to 100g of americium-241. Finally, the paper offers a rapid summary of the effects of standardization at the various stages concerned, from initial design to the commissioning of a hot laboratory. (author)

  7. Optical Fier Based System for Multiple Thermophysical Properties for Glove Box, Hot Cell and In-Pile Application

    Energy Technology Data Exchange (ETDEWEB)

    Ban, Heng

    2017-11-30

    Thermal diffusivity of materials is of interest in nuclear applications at temperatures in excess of 2000°C. Commercial laser flash apparatus (LFA) that heats samples with a furnace typically do not reach these elevated temperatures nor are they easily adapted to a glove-box or hot cell environment. In this research, we performed work on an experimental technique using single laser surface heating, i.e. heating the disk sample only at its front surface with the continuous wave (CW) laser, to allow measurement of thermal diffusivity at very high temperatures within a small chamber. Thermal diffusivity is measured using a separate pulsed laser on the front side and IR detector on the rear side. The new way of heating provides easy operation in comparison to other heating methods. The measurement of sample reference temperature is needed for the measured thermal diffusivity. A theoretical model was developed to describe transient heat transfer across the sample due to the laser pulse, starting from the steady state temperature of the sample heated by the CW laser. The experimental setup was established with a 500W CW laser and maximum 50 Joule pulse laser irradiated at the front surface of the sample. The induced temperature rise at the rear surface, along with the steady-state temperature at the front surface, was recorded for the determination of thermal diffusivity and the sample temperature. Three samples were tested in vacuum over a wide temperature range of 500°C to 2100°C, including graphite, Inconel 600 and tungsten. The latter two samples were coated with sprayed graphite on their front surfaces in order to achieve surface absorption/emission needs, i.e. high absorptivity of the front surface against relatively low emissivity of the rear surface. Thermal diffusivity of graphite determined by our system are within a 5% difference of the commercial LFA data at temperatures below 1300°C and agree well with its trend at higher temperatures. Good agreement

  8. Virtual Box

    DEFF Research Database (Denmark)

    Davis, Hilary; Skov, Mikael B.; Stougaard, Malthe

    2007-01-01

    . This paper reports on the design, implementation and initial evaluation of Virtual Box. Virtual Box attempts to create a physical and engaging context in order to support reciprocal interactions with expressive content. An implemented version of Virtual Box is evaluated in a location-aware environment...

  9. Thermal performance parameters estimation of hot box type solar cooker by using artificial neural network

    Energy Technology Data Exchange (ETDEWEB)

    Kurt, Hueseyin; Atik, Kemal; Oezkaymak, Mehmet; Recebli, Ziyaddin [Zonguldak Karaelmas University, Karabuk Technical Education Faculty, 78200 Karabuk (Turkey)

    2008-02-15

    Work to date has shown that Artificial Neural Network (ANN) has not been used for predicting thermal performance parameters of a solar cooker. The objective of this study is to predict thermal performance parameters such as absorber plate, enclosure air and pot water temperatures of the experimentally investigated box type solar cooker by using the ANN. Data set is obtained from the box type solar cooker which was tested under various experimental conditions. A feed-forward neural network based on back propagation algorithm was developed to predict the thermal performance of solar cooker with and without reflector. Mathematical formulations derived from the ANN model are presented for each predicting temperatures. The experimental data set consists of 126 values. These were divided into two groups, of which the 96 values were used for training/learning of the network and the rest of the data (30 values) for testing/validation of the network performance. The performance of the ANN predictions was evaluated by comparing the prediction results with the experimental results. The results showed a good regression analysis with the correlation coefficients in the range of 0.9950-0.9987 and mean relative errors (MREs) in the range of 3.925-7.040% for the test data set. The regression coefficients indicated that the ANN model can successfully be used for the prediction of the thermal performance parameters of a box type solar cooker with a high degree of accuracy. (author)

  10. Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Miller, D. C.; Wohlgemuth, J. H.

    2012-08-01

    Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed to verify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results, a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observed failure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

  11. Holdup measurements of plutonium in glove box exhausts

    International Nuclear Information System (INIS)

    Glick, J.B.; Haas, F.X.; McKamy, J.N.; Garrett, A.G.

    1991-01-01

    A new measurement technique has been developed to quantify plutonium in process glove box exhausts. The technique implemented at Rocky Flats Plant utiltizes a shielded, collimated 0.5in. x 0.5in. bismuth germanate (BGO) gamma-ray detector. Pairs of measurements are made at one foot intervals along the duct. One measurement is made with the detector viewing the bottom of the duct with the detector crystal approximately 2 inches from the duct surface. The second measurement is made on the top of the exhaust pipe with the detector crystal 2 inches from the top of the duct. When the detector is placed in the bottom assay position, the area of the holdup material is assumed to extend beyond the detector field of view. The concentration of plutonium in g/cm 2 is obtained from this bottom measurement. The deposit width is determined from a model developed to relate the deposit width to the ratio of the count rates measured at the two positions, above and below the duct. Once a deposit width has been calculated, it is multiplied by the concentration determined from the bottom measurement to yield a mass- per-unit-length at the duct location. Total plutonium mass is then determined by multiplying the duct length by the average of the mass- per-unit length assays performed along the duct. The applicability of the technique is presented in a comparison of field measurement data to analysis results on material removed from the ducts. 3 refs., 3 figs., 1 tab

  12. General gamma-radiation test of TGC detectors

    CERN Document Server

    Smakhtin, V P

    2004-01-01

    The TGC detectors are expected to provide the Muon trigger for the ATLAS detector in the forward region of the ATLAS Muon Spectrometer. The TGC detectors have to provide a trigger signal within 25 ns of the LHC accelerator bunch spacing, with an efficiency exceeding 95%, while exposed to an effective)photon and neutron background ranging from 30 to 150 Hz/cm/sup 2/. In order to test TGC detectors in high rate environment every detector was irradiated at 2500 Cu Co-60 source in Radiation Facility of Weizmann Institute of Science at nominal operating voltage and at photon rate several times above the expected background. This radiation test was succeeded in diagnostics of the hot spots inside detectors. The present publication refers to the test results of 800 TGC detectors produced in the Weizmann Institute of Science. (1 refs).

  13. Detection of insulation flaws and thermal bridges in insulated truck box panels

    OpenAIRE

    Lei, Lei; Bortolin, Alessandro; Bison, Paolo ©; Maldague, X.

    2017-01-01

    This paper focuses on the detection of defects and thermal bridges in insulated truck box panels, utilising infrared thermography. Unlike the traditional way in which passive thermography is applied, this research uses both heating and cooling methods in active thermography configurations. Lamp heating is used as the hot external stimulation, while a compressed air jet is applied as the cold external stimulation. A thermal camera captures the whole process. In addition, numerical simulations ...

  14. Modelling of airflow in a closed simulation box with regard to atmospheric optical link

    Directory of Open Access Journals (Sweden)

    Hajek Lukas

    2014-03-01

    Full Text Available Article is dealing with defining of mathematical turbulent air flow numerical model in the laboratory box with help of ANSYS Fluent software application. The paper describes real measurement of parameters of mechanical turbulences created by high-speed ventilator mounted on the simulation box. The real measurement took place in two planes perpendicular to each other, input and output slot. Subsequently the simulation of mechanical air flow was performed by the help of k-ε and k-ω turbulent models. The results of individual simulations were evaluated by statistical model in the same points, planes respectively, in which the real measurement was made. Other simulation was dealing with effect of heaters inside of closed laboratory box with regards to optical beam degradation. During real measurement was performed temperature point measurement by probe placed inside of the box. The probe was recording air temperature every one second during seven minutes long measurement. The results comparison of simulated and measured data was made in the end. The maximal temperature reached approximately 50 °C in both cases. Also the air flow character in dependence on the number of hot-air extraction ventilators was monitored.

  15. WFC3 UVIS Detector Performance

    Science.gov (United States)

    Gunning, Heather C.; Baggett, Sylvia M.; Gosmeyer, Catherine; Bourque, Matthew; MacKenty, John W.; Anderson, Jay; WFC3 Team

    2015-01-01

    The Wide Field Camera 3 (WFC3) is a fourth-generation imaging instrument installed on the Hubble Space Telescope (HST) during Servicing Mission 4 (SM4) in May 2000. WFC3 has two observational channels, UV/visible (UVIS) and infrared (IR); both have been performing well on-orbit. Since installation, the WFC3 team has been diligent in monitoring the performance of both detectors. The UVIS channel consists of two e2v, backside illuminated, 2Kx4K CCDs arranged in a 2x1 mosaic. We present results from some of the monitoring programs used to check various aspects of the UVIS detector. We discuss the growth trend of hot pixels and the efficacy of regular anneals in controlling the hot pixel population. We detail a pixel population with lowered-sensitivity that evolves during the time between anneals, and is largely reset by each anneal procedure. We discuss the stability of the post-flash LED lamp, used and recommended for CTE mitigation in observations with less than 12 e-/pixel backgrounds. Finally, we summarize long-term photometric trends of the UVIS detector, as well as the absolute gain measurement, used as a proxy for the on-orbit evolution of the UVIS channel.

  16. Mechanical Analysis of an Innovative Assembly Box with Honeycomb Structures Designed for a High Performance Light Water Reactor

    International Nuclear Information System (INIS)

    Herbell, Heiko; Himmel, Steffen; Schulenberg, Thomas

    2008-01-01

    The High Performance Light Water Reactor (HPLWR) is a water cooled reactor concept of the 4. generation, operated at a pressure beyond the critical point of water. Assemblies of this innovative reactor concept need to be built with assembly and moderator boxes, like boiling water reactors, to provide enough moderator water between them to compensate the low coolant density in the core. Hot, superheated steam conditions, on the other hand, require thermally insulated box walls rather than solid box walls to reduce the heat up of the moderator water. As a new an innovative approach, this paper describes moderator- and assembly boxes built from stainless steel honeycomb sandwich structures, in which the honeycomb cells are filled with alumina for thermal insulation. In comparison to solid box walls, the use of the presented design can provide the same stiffness but allows a drastic reduction of structural material and thus less neutron absorption. Finite element analyses are used to verify the required stiffness, to identify stress concentrations and to optimize the design. (authors)

  17. 46 CFR 111.81-1 - Outlet boxes and junction boxes; general.

    Science.gov (United States)

    2010-10-01

    ... fixture, wiring device, or similar item, including each separately installed connection and junction box... used. (d) As appropriate, each outlet-box or junction-box installation must meet the following...

  18. Statistical analysis of process parameters to eliminate hot cracking of fiber laser welded aluminum alloy

    Science.gov (United States)

    Wang, Jin; Wang, Hui-Ping; Wang, Xiaojie; Cui, Haichao; Lu, Fenggui

    2015-03-01

    This paper investigates hot cracking rate in Al fiber laser welding under various process conditions and performs corresponding process optimization. First, effects of welding process parameters such as distance between welding center line and its closest trim edge, laser power and welding speed on hot cracking rate were investigated experimentally with response surface methodology (RSM). The hot cracking rate in the paper is defined as ratio of hot cracking length over the total weld seam length. Based on the experimental results following Box-Behnken design, a prediction model for the hot cracking rate was developed using a second order polynomial function considering only two factor interaction. The initial prediction result indicated that the established model could predict the hot cracking rate adequately within the range of welding parameters being used. The model was then used to optimize welding parameters to achieve cracking-free welds.

  19. Manual on Safety Aspects of the Design and Equipment of Hot Laboratories

    International Nuclear Information System (INIS)

    1969-01-01

    With the development of atomic energy application and research, hot laboratories are now being constructed in a number of countries. The present publication describes and discusses experience in several countries in designing equipment for these laboratories. The safe handling of highly radioactive substances is the main purpose of hot laboratory design and equipment. The manual aims at helping those persons, particularly in the developing countries, who plan to design and construct a new hot laboratory or modify an existing one. It does not deal in great detail with the engineering design of protective and handling equipment; these matters can be found in the comprehensive list of references. The manual itself covers only basic ideas and different approaches in the design of laboratory building, hot cells, shielded and glove boxes, fume cupboards, and handling and viewing equipment. Systems for transferring materials and main services are also discussed.

  20. Robotic and nuclear safety for an automated/teleoperated glove box system

    International Nuclear Information System (INIS)

    Domning, E.E.; McMahon, T.T.; Sievers, R.H.

    1991-09-01

    Lawrence Livermore National Laboratory (LLNL) is developing a fully automated system to handle the processing of special nuclear materials (SNM). This work is performed in response to the new goals at the Department of Energy (DOE) for hazardous waste minimization and radiation dose reduction. This fully automated system, called the automated test bed (ATB), consists of an IBM gantry robot and automated processing equipment sealed within a glove box. While the ATB is a cold system, we are designing it as a prototype of the future hot system. We recognized that identification and application of safety requirements early in the design phase will lead to timely installation and approval of the hot system. This paper identifies these safety issues as well as the general safety requirements necessary for the safe operation of the ATB. 4 refs., 2 figs

  1. The Cosmic Ray Tracking (CRT) detector system

    International Nuclear Information System (INIS)

    Bernloehr, K.; Gamp, S.; Hermann, G.; Hofmann, W.; Kihm, T.; Knoeppler, J.; Leffers, G.; Matheis, V.; Panter, M.; Trunk, U.; Ulrich, M.; Wolf, T.; Zink, R.; Heintze, J.

    1996-01-01

    The Cosmic Ray Tracking (CRT) project represents a study on the use of tracking detectors of the time projection chamber type to detect secondary cosmic ray particles in extensive air showers. In reconstructing the arrival direction of the primary cosmic ray particles, the CRT detectors take advantage of the angular correlation of secondary particles with the cosmic rays leading to these air showers. In this paper, the detector hardware including the custom-designed electronics system is described in detail. A CRT detector module provides an active area of 2.5 m 2 and allows to measure track directions with a precision of 0.4 circle . It consists of two circular drift chambers of 1.8 m diameter with six sense wires each, and a 10 cm thick iron plate between the two chambers. Each detector has a local electronics box with a readout, trigger, and monitoring system. The detectors can distinguish penetrating muons from other types of charged secondaries. A large detector array could be used to search for γ-ray point sources at energies above several TeV and for studies of the cosmic-ray composition. Ten detectors are in operation at the site of the HEGRA air shower array. (orig.)

  2. The GlueX DIRC detector

    Science.gov (United States)

    Barbosa, F.; Bessuille, J.; Chudakov, E.; Dzhygadlo, R.; Fanelli, C.; Frye, J.; Hardin, J.; Kelsey, J.; Patsyuk, M.; Schwarz, C.; Schwiening, J.; Stevens, J.; Shepherd, M.; Whitlatch, T.; Williams, M.

    2017-12-01

    The GlueX DIRC (Detection of Internally Reflected Cherenkov light) detector is being developed to upgrade the particle identification capabilities in the forward region of the GlueX experiment at Jefferson Lab. The GlueX DIRC will utilize four existing decommissioned BaBar DIRC bar boxes, which will be oriented to form a plane roughly 4 m away from the fixed target of the experiment. A new photon camera has been designed that is based on the SuperB FDIRC prototype. The full GlueX DIRC system will consist of two such cameras, with the first planned to be built and installed in 2017. We present the current status of the design and R&D, along with the future plans of the GlueX DIRC detector.

  3. Channel box

    International Nuclear Information System (INIS)

    Tanabe, Akira.

    1993-01-01

    In a channel box of a BWR type reactor, protruding pads are disposed in axial position on the lateral side of a channel box opposing to a control rod and facing the outer side portion of the control rod in a reactor core loaded state. In the initial loading stage of fuel assemblies, channel fasteners and spacer pads are abutted against each other in the upper portion between the channel boxes sandwiching the control rod therebetween. Further, in the lower portion, a gap as a channel for the movement of the control rod is ensured by the support of fuel support metals. If the channel box is bent toward the control rod along with reactor operation, the pads are abutted against each other to always ensure the gap through which the control rod can move easily. Further, when the pads are brought into contact with each other, the bending deformation of the channel box is corrected by urging to each other. Thus, the control rod can always be moved smoothly to attain reactor safety operation. (N.H.)

  4. An endoscopic detector for ultracold neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Goeltl, L.; Fertl, M.; Kirch, K. [Paul Scherrer Institute, Laboratory for Particle Physics, Villigen-PSI (Switzerland); Institute for Particle Physics, Zuerich (Switzerland); Chowdhuri, Z.; Henneck, R.; Lauss, B.; Mtchedlishvili, A.; Schmidt-Wellenburg, P.; Zsigmond, G. [Paul Scherrer Institute, Laboratory for Particle Physics, Villigen-PSI (Switzerland); Gray, F. [Regis University, Denver, CO (United States); Lefort, T. [Universite de Caen, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, Caen (France)

    2013-01-15

    A new versatile detector for ultracold neutrons (UCN) has been built and operated which combines multi-pixel photon counters and GS10 lithium-doped scintillators. Such detectors can be very small and can be used to monitor UCN inside storage vessels or guides with negligible influence (of order 10{sup -6}) on the UCN intensity itself. We have shown that such detectors can be used in a very harsh radiation environment of up to 200Gy/h via the addition of a 4m long quartz light guide in order to place the radiation-sensitive photon counters outside the hot zone. Additionally we have measured the UCN storage times in situ in this harsh environment. (orig.)

  5. Decommissioning of the Risoe hot cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1992-02-01

    Concise descriptions of actions taken in relation to the decommissioning of the hot cell facility at Risoe National Laboratory are presented. The removal of fissile material, of large contaminated equipment from the concrete cell line and a separate shielded storage facility, and the removal of large contaminated facilities such as out cell parts of a tube transport system between a concrete cell and a lead shielded steel box and a remotely operated Reichert Telatom microscope housed in a lead shielded glove box is described in addition to the initial mapping of radiation levels related to the decontamination of concrete cells. The dose commitment of 17.7 mSv was ascribed to 12 persons in the 2nd half of 1991. The work resulting in these doses was mainly handling of waste together with the frogman entrances in order to repair the in-cell crane and power manipulator. The overall time schedule for the project still appears to be applicable. (AB)

  6. Multi detector input and function generator for polarized neutron experiments

    International Nuclear Information System (INIS)

    De Blois, J.; Beunes, A.J.H.; Ende, P. v.d.; Osterholt, E.A.; Rekveldt, M.T.; Schipper, M.N.; Velthuis, S.G.E. te

    1998-01-01

    In this paper a VME module is described for static or stroboscopic measurements with a neutron scattering instrument, consisting essentially of a series of up to 64 3 He neutron detectors around a sample environment. Each detector is provided with an amplifier and a discriminator to separate the neutrons from noise. To reduce the wiring, the discriminator outputs are connected to the module by coding boxes. Two 16-inputs to one-output coding boxes generate serial output codes on a fiber optic connection. This basically fast connection reduces the dead time introduced by the coding, and the influence of environmental noise. With stroboscopic measurements a periodic function is used to affect the sample surrounded by a field coil. Each detected neutron is labeled with a data label containing the detector number and the time of detection with respect to a time reference. The data time base can be programmed on a linear or a nonlinear scale. An external source or an attribute of the periodic function may generate the time reference pulse. A 12-bit DAC connected to the output of an 8 K, 16-bits memory, where the pattern of the current has been stored before, generates the function. The function memory is scanned by the programmable function time base. Attributes are set by the four remaining bits of the memory. One separate detector input connects a monitor detector in the neutron beam with a 32-bit counter/timer that provides measuring on a preset count, preset time or preset frame. (orig.)

  7. Neutron activation analysis of the rare earth elements in Nasu hot springs

    International Nuclear Information System (INIS)

    Ikeda, Nagao; Takahashi, Naruto.

    1978-01-01

    Eleven rare earth elements (lanthanum, cerium, neodymium, samarium, europium, gadolinium, terbium, holmium, thulium, ytterbium and lutetium) in hot spring waters and sinter deposits in the Nasu area were determined by the neutron activation method. The rare earth elements in hot spring water were preconcentrated in ferric hydroxide precipitate and neutron-irradiated. The rare earth elements were chemically separated into lighter and heavier groups and the activity of each group was measured with a Ge(Li) detector. Distribution of the rare earth elements between the hot spring water and the sinter deposit was also discussed. (auth.)

  8. Hot forming of composite prepreg : Experimental study

    Science.gov (United States)

    Tardif, Xavier; Duthille, Bertrand; Bechtel, Stephane; le Pinru, Louis; Campagne, Benjamin; Destombes, Gautier; Deshors, Antoine; Marchand, Christophe; Azzouzi, Khalid El; Moro, Tanguy

    2017-10-01

    The hot forming of thermoset prepreg consists in bending an uncured composite part by applying a mechanical constrain on the hot laminate. Most of the time, the mold is inserted in a vacuum box and the mechanical constrain is applied on the composite laminate by a single membrane or a double-membrane. But the performance improvement products resulted in forming increasingly complex parts with advanced materials having a less formability. These new complex parts require a finer comprehension of the process and an optimization of the key parameters to get acceptable quality. In this work, an experimental study has been carried out to identify the process conditions that do not lead to unacceptable defaults: undulations of fibers. In the present study, downward-bending has been evaluated with an original light mechanical forming concept, for a given stacking sequence. The influence of the part's temperature and the part's bending speed are investigated. To carry this study out, a hot forming test bench has been designed and manufactured to have a precise supervision of the process conditions. It is able to bend parts of 1500 mm length x 600 mm width x 20 mm thick.

  9. New Type Far IR and THz Schottky Barrier Detectors for Scientific and Civil Application

    Directory of Open Access Journals (Sweden)

    V. G. Ivanov

    2011-01-01

    Full Text Available The results of an experimental investigation into a new type of VLWIR detector based on hot electron gas emission and architecture of the detector are presented and discussed. The detectors (further referred to as HEGED take advantage of the thermionic emission current change effect in a semiconductor diode with a Schottky barrier (SB as a result of the direct transfer of the absorbed radiation energy to the system of electronic gas in the quasimetallic layer of the barrier. The possibility of detecting radiation having the energy of quantums less than the height of the Schottky diode potential barrier and of obtaining a substantial improvement of a cutoff wavelength to VLWIR of the PtSi/Si detector has been demonstrated. The complementary contribution of two physical mechanisms of emanation detection—“quantum” and hot electrons gas emission—has allowed the creation of a superwideband IR detector using standard silicon technology.

  10. Air tight electrical box

    Energy Technology Data Exchange (ETDEWEB)

    Pringle, C.G.

    1990-08-14

    An air-impervious electrical box to facilitate air sealing a house comprises an integral, rigid box body having a continuous flange, integral with the body, circumscribing and outwardly extending from the sides of the body. This flange is rearwardly positioned behind the front edges of the sides of the body a predetermined distance so that the electrical box may be secured to framing by nailing through the flange. Drywall is then secured to the frame on top of and adjecent to the flange. Such box eliminates the necessity for solid backing and minimizes passage of air through the box and space between the drywall and the box.

  11. Phonon-mediated distributed transition-edge-sensor X-ray detectors for surveys of galaxy clusters and the warm-hot interstellar medium

    International Nuclear Information System (INIS)

    Leman, Steven W.; Brink, Paul L.; Cabrera, Blas; Castle, Joseph P.; Chakraborty, Sudeepto; Deiker, Steve; Kahn, Steve; Martinez-Galarce, Dennis S.; Stern, Robert A.; Tomada, Astrid

    2006-01-01

    We are developing a novel phonon-mediated distributed-TES X-ray detector in which X-rays are absorbed in a large germanium or silicon crystal, and the energy is read out by four distributed TESs. This design takes advantage of existing TES technology while overcoming the difficulties of designing spatially large arrays. The sum of the four TES signals will yield energy resolution of E/δE∼1000 and the partitioning of energy between the four will yield position resolution of X/δX and Y/δY∼100. These macropixels, with advances in multiplexing, could be close-packed into 30x30 arrays equivalent to imaging instruments of 10 megapixels or more. We report on our progress to date and discuss its application to galaxy cluster searches and studies of the Warm-Hot Interstellar Medium

  12. Measurement of Radon concentration in groundwater by technique of nuclear track detector

    International Nuclear Information System (INIS)

    Trinh Van Giap; Nguyen Manh Hung; Dang Duc Nhan

    2000-01-01

    A method for measuring radon concentration in groundwater using nuclear track detector LR-115 stripping is reported. The radon-monitoring device in groundwater is a small box with two pieces of nuclear track detector and all these materials is placed in a plastic bag made by polyethylene. It is very suitable to measure radon concentration in groundwater well in long term. Alpha tracks produced by radon and it daughter on nuclear track detector is counted automatically by spark counting method. The paper also presents some results of radon concentration in some groundwater well and mineral water sources. (author)

  13. Au nanoparticle-decorated silicon pyramids for plasmon-enhanced hot electron near-infrared photodetection

    Science.gov (United States)

    Qi, Zhiyang; Zhai, Yusheng; Wen, Long; Wang, Qilong; Chen, Qin; Iqbal, Sami; Chen, Guangdian; Xu, Ji; Tu, Yan

    2017-07-01

    The heterojunction between metal and silicon (Si) is an attractive route to extend the response of Si-based photodiodes into the near-infrared (NIR) region, so-called Schottky barrier diodes. Photons absorbed into a metallic nanostructure excite the surface plasmon resonances (SPRs), which can be damped non-radiatively through the creation of hot electrons. Unfortunately, the quantum efficiency of hot electron detectors remains low due to low optical absorption and poor electron injection efficiency. In this study, we propose an efficient and low-cost plasmonic hot electron NIR photodetector based on a Au nanoparticle (Au NP)-decorated Si pyramid Schottky junction. The large-area and lithography-free photodetector is realized by using an anisotropic chemical wet etching and rapid thermal annealing (RTA) of a thin Au film. We experimentally demonstrate that these hot electron detectors have broad photoresponsivity spectra in the NIR region of 1200-1475 nm, with a low dark current on the order of 10-5 A cm-2. The observed responsivities enable these devices to be competitive with other reported Si-based NIR hot electron photodetectors using perfectly periodic nanostructures. The improved performance is attributed to the pyramid surface which can enhance light trapping and the localized electric field, and the nano-sized Au NPs which are beneficial for the tunneling of hot electrons. The simple and large-area preparation processes make them suitable for large-scale thermophotovoltaic cell and low-cost NIR detection applications.

  14. Design and R&D of RICH detectors for EIC experiments

    Science.gov (United States)

    Del Dotto, A.; Wong, C.-P.; Allison, L.; Awadi, M.; Azmoun, B.; Barbosa, F.; Brooks, W.; Cao, T.; Chiu, M.; Cisbani, E.; Contalbrigo, M.; Datta, A.; Demarteau, M.; Durham, J. M.; Dzhygadlo, R.; Fields, D.; Furletova, Y.; Gleason, C.; Grosse-Perdekamp, M.; Harris, J.; He, X.; van Hecke, H.; Horn, T.; Huang, J.; Hyde, C.; Ilieva, Y.; Kalicy, G.; Kimball, M.; Kistenev, E.; Kulinich, Y.; Liu, M.; Majka, R.; McKisson, J.; Mendez, R.; Nadel-Turonski, P.; Park, K.; Peters, K.; Rao, T.; Pisani, R.; Qiang, Y.; Rescia, S.; Rossi, P.; Sarsour, M.; Schwarz, C.; Schwiening, J.; da Silva, C. L.; Smirnov, N.; Stein, H.; Stevens, J.; Sukhanov, A.; Syed, S.; Tate, A.; Toh, J.; Towell, C.; Towell, R.; Tsang, T.; Wagner, R.; Wang, J.; Woody, C.; Xi, W.; Xie, J.; Zhao, Z. W.; Zihlmann, B.; Zorn, C.

    2017-12-01

    An Electron-Ion Collider (EIC) has been proposed to further explore the strong force and QCD, focusing on the structure and the interaction of gluon-dominated matter. A generic detector R&D program (EIC PID consortium) for the particle identification in EIC experiments was formed to explore technologically advanced solutions in this scope. In this context two Ring Imaging Cherenkov (RICH) counters have been proposed: a modular RICH detector which consists of an aerogel radiator, a Fresnel lens, a mirrored box, and pixelated photon sensor; a dual-radiator RICH, consisting of an aerogel radiator and C2F6 gas in a mirror-focused configuration. We present the simulations of the two detectors and their estimated performance.

  15. Monte Carlo simulation experiments on box-type radon dosimeter

    International Nuclear Information System (INIS)

    Jamil, Khalid; Kamran, Muhammad; Illahi, Ahsan; Manzoor, Shahid

    2014-01-01

    Epidemiological studies show that inhalation of radon gas ( 222 Rn) may be carcinogenic especially to mine workers, people living in closed indoor energy conserved environments and underground dwellers. It is, therefore, of paramount importance to measure the 222 Rn concentrations (Bq/m 3 ) in indoors environments. For this purpose, box-type passive radon dosimeters employing ion track detector like CR-39 are widely used. Fraction of the number of radon alphas emitted in the volume of the box type dosimeter resulting in latent track formation on CR-39 is the latent track registration efficiency. Latent track registration efficiency is ultimately required to evaluate the radon concentration which consequently determines the effective dose and the radiological hazards. In this research, Monte Carlo simulation experiments were carried out to study the alpha latent track registration efficiency for box type radon dosimeter as a function of dosimeter’s dimensions and range of alpha particles in air. Two different self developed Monte Carlo simulation techniques were employed namely: (a) Surface ratio (SURA) method and (b) Ray hitting (RAHI) method. Monte Carlo simulation experiments revealed that there are two types of efficiencies i.e. intrinsic efficiency (η int ) and alpha hit efficiency (η hit ). The η int depends upon only on the dimensions of the dosimeter and η hit depends both upon dimensions of the dosimeter and range of the alpha particles. The total latent track registration efficiency is the product of both intrinsic and hit efficiencies. It has been concluded that if diagonal length of box type dosimeter is kept smaller than the range of alpha particle then hit efficiency is achieved as 100%. Nevertheless the intrinsic efficiency keeps playing its role. The Monte Carlo simulation experimental results have been found helpful to understand the intricate track registration mechanisms in the box type dosimeter. This paper explains that how radon

  16. Monte Carlo simulation experiments on box-type radon dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Jamil, Khalid, E-mail: kjamil@comsats.edu.pk; Kamran, Muhammad; Illahi, Ahsan; Manzoor, Shahid

    2014-11-11

    Epidemiological studies show that inhalation of radon gas ({sup 222}Rn) may be carcinogenic especially to mine workers, people living in closed indoor energy conserved environments and underground dwellers. It is, therefore, of paramount importance to measure the {sup 222}Rn concentrations (Bq/m{sup 3}) in indoors environments. For this purpose, box-type passive radon dosimeters employing ion track detector like CR-39 are widely used. Fraction of the number of radon alphas emitted in the volume of the box type dosimeter resulting in latent track formation on CR-39 is the latent track registration efficiency. Latent track registration efficiency is ultimately required to evaluate the radon concentration which consequently determines the effective dose and the radiological hazards. In this research, Monte Carlo simulation experiments were carried out to study the alpha latent track registration efficiency for box type radon dosimeter as a function of dosimeter’s dimensions and range of alpha particles in air. Two different self developed Monte Carlo simulation techniques were employed namely: (a) Surface ratio (SURA) method and (b) Ray hitting (RAHI) method. Monte Carlo simulation experiments revealed that there are two types of efficiencies i.e. intrinsic efficiency (η{sub int}) and alpha hit efficiency (η{sub hit}). The η{sub int} depends upon only on the dimensions of the dosimeter and η{sub hit} depends both upon dimensions of the dosimeter and range of the alpha particles. The total latent track registration efficiency is the product of both intrinsic and hit efficiencies. It has been concluded that if diagonal length of box type dosimeter is kept smaller than the range of alpha particle then hit efficiency is achieved as 100%. Nevertheless the intrinsic efficiency keeps playing its role. The Monte Carlo simulation experimental results have been found helpful to understand the intricate track registration mechanisms in the box type dosimeter. This paper

  17. A university hot laboratory for teaching and research

    International Nuclear Information System (INIS)

    Heinonen, O.; Miettinen, J.K.

    1976-01-01

    In small countries which have limited material and capital resources there is more need for studying and teaching reactor chemistry in universities than there is in countries with special nuclear research and training centres. A new 150-m 2 laboratory of reactor chemistry was added to the premises of the Department of Radiochemistry, University of Helsinki, in October 1975. It contains a hot area with low-pressure air-conditioning, a sanitary room, a low-activity area, and an office area. The main instrument is a mass-spectrometer MI-1309 equipped with an ion counter which is particularly useful for plutonium analysis. The laboratory can handle samples up-to 10Ci gamma-acitivity - which equals one pellet of a fuel rod - in a sealed lead cell which has an interchangeable box for alpha-active work. Pretreated samples are submitted to chemical separations in glove-boxes. Samples for alpha and mass spectroscopy are also prepared in glove-boxes. Also the laboratory is provided with fume hoods suitable for building lead shields. Radiation protection and special features typical to the university environment are discussed. Methods for verfication of contamination and protection against internal and external contamination are applied. These include air monitoring, analysis of excreta, and whole-body counting. (author)

  18. A Single Tower Configuration of the Modular Gamma Box Counter System - 13392

    Energy Technology Data Exchange (ETDEWEB)

    Morris, K.; Nakazawa, D.; Francalangia, J.; Gonzalez, H. [Canberra Industries Inc., 800 Research Parkway, Meriden, CT, 06450 (United States)

    2013-07-01

    Canberra's Standard Gamma Box Counter System is designed to perform accurate quantitative assays of gamma emitting nuclides for a wide range of large containers including B-25 crates and ISO shipping containers. Using a modular building-block approach, the system offers tremendous flexibility for a variety of measurement situations with wide ranges of sample activities and throughput requirements, as well as the opportunity to modify the configuration for other applications at a later date. The typical configuration consists of two opposing towers each equipped with two high purity germanium detectors, and an automated container trolley. This paper presents a modified configuration, consisting of a single tower placed inside a measurement trailer with three detector assemblies, allowing for additional vertical segmentation as well as a viewing a container outside the trailer through the trailer wall. An automatic liquid nitrogen fill system is supplied for each of the detectors. The use of a forklift to move the container for horizontal segmentation is accommodated by creating an additional operational and calibration set-up in the NDA 2000 software to allow for the operator to rotate the container and assay the opposite side, achieving the same sensitivity as a comparable two-tower system. This Segmented Gamma Box Counter System retains the core technologies and design features of the standard configuration. The detector assemblies are shielded to minimize interference from environmental and plant background, and are collimated to provide segmentation of the container. The assembly positions can also be modified in height and distance from the container. The ISOCS calibration software provides for a flexible approach to providing the calibrations for a variety of measurement geometries. The NDA 2000 software provides seamless operation with the current configuration, handling the data acquisition and analysis. In this paper, an overview of this system is

  19. An ultrafast NbN hot-electron single-photon detector for electronic applications

    International Nuclear Information System (INIS)

    Lipatov, A; Okunev, O; Smirnov, K; Chulkova, G; Korneev, A; Kouminov, P; Gol'tsman, G; Zhang, J; Slysz, W; Verevkin, A; Sobolewski, R

    2002-01-01

    We present the latest generation of our superconducting single-photon detector (SPD), which can work from ultraviolet to mid-infrared optical radiation wavelengths. The detector combines a high speed of operation and low jitter with high quantum efficiency (QE) and very low dark count level. The technology enhancement allows us to produce ultrathin (3.5 nm thick) structures that demonstrate QE hundreds of times better, at 1.55 μm, than previous 10 nm thick SPDs. The best, 10x10 μm 2 , SPDs demonstrate QE up to 5% at 1.55 μm and up to 11% at 0.86 μm. The intrinsic detector QE, normalized to the film absorption coefficient, reaches 100% at bias currents above 0.9 I c for photons with wavelengths shorter than 1.3 μm

  20. A new kind of metal detector based on chaotic oscillator

    Science.gov (United States)

    Hu, Wenjing

    2017-12-01

    The sensitivity of a metal detector greatly depends on the identification ability to weak signals from the probe. In order to improve the sensitivity of metal detectors, this paper applies the Duffing chaotic oscillator to metal detectors based on its characteristic which is very sensitive to weak periodic signals. To make a suitable Duffing system for detectors, this paper computes two Lyapunov characteristics exponents of the Duffing oscillator, which help to obtain the threshold of the Duffing system in the critical state accurately and give quantitative criteria for chaos. Meanwhile, a corresponding simulation model of the chaotic oscillator is made by the Simulink tool box of Matlab. Simulation results shows that Duffing oscillator is very sensitive to sinusoidal signals in high frequency cases. And experimental results show that the measurable diameter of metal particles is about 1.5mm. It indicates that this new method can feasibly and effectively improve the metal detector sensitivity.

  1. Medical and Safety Reforms in Boxing

    Science.gov (United States)

    Jordan, Barry D.

    1988-01-01

    The continued existence of boxing as an accepted sport in civilized society has been long debated. The position of the American Medical Association (AMA) has evolved from promoting increased safety and medical reform to recommending total abolition of both amateur and professional boxing. In response to the AMA opposition to boxing, the boxing community has attempted to increase the safeguards in amateur and professional boxing. The United States of America Amateur Boxing Federation, which is the national regulatory agency for all amateur boxing in the United States, has taken several actions to prevent the occurrence of acute brain injury and is currently conducting epidemiologic studies to assess the long-term neuropsychologic consequences of amateur boxing. In professional boxing, state regulatory agencies such as the New York State Athletic Commission have introduced several medical interventions to prevent and reduce neurologic injury. The lack of a national regulatory agency to govern professional boxing has stimulated the formation of the Association of Boxing Commissions and potential legislation for the federal regulation of professional boxing by a federally chartered organization called the United States Boxing Commission. The AMA's opposition to boxing and the medical and safety reforms implemented by the proponents of boxing are discussed. PMID:3385788

  2. SiliPET: An ultra high resolution design of a small animal PET scanner based on double sided silicon strip detector stacks

    International Nuclear Information System (INIS)

    Zavattini, G.; Cesca, N.; Di Domenico, G.; Moretti, E.; Sabba, N.

    2006-01-01

    We investigated the capabilities of a small animal PET scanner, named SiliPET, based on four stacks of double sided silicon strips detectors. Each stack consists of 40 silicon detectors with dimension 60x60x1mm 3 . These are arranged to form a box 5x5x6cm 3 with minor sides opened; the box represents the maximal FOV of the scanner. The performance parameters of SiliPET scanner have been estimated, giving an intrinsic spatial resolution of 0.52mm and a sensitivity of 5.1% at the center of the system

  3. Glove box

    International Nuclear Information System (INIS)

    Morita, Atsushi

    1990-01-01

    Wire rope earthquake proof supports having sufficient vibration transmitting and attenuating property are disposed between a fixed floor and the bottom of a glove box in order to improve earthquake proofness of the glove box. The vertical weight of the glove box is supported by support legs slidable on the surface of the fixed floor. The wire rope earthquake-proof supports when undergoing a load, cause stretching and rolling against the external force such as earthquakes, and provide flexible spring support and cause a great damping due to friction with strands. Further, the vertical weight is always supported by the support legs and, when a horizontal weight is applied, the glove box slides on the fixed floor freely with slidable members. In this way, stress concentration generated at joint portions of columns and beams can be moderated greatly and earthquake proofness can be improved. Further, quality control and maintenance for the device is almost unnecessary owing to excellent fatigue-resistant characteristics of the wire rope earthquake proof supports. (N.H.)

  4. VHMPID: a new detector for the ALICE experiment at LHC

    Directory of Open Access Journals (Sweden)

    Perini D.

    2011-04-01

    Full Text Available This article presents the basic idea of VHMPID, an upgrade detector for the ALICE experiment at LHC, CERN. The main goal of this detector is to extend the particle identification capabilities of ALICE to give more insight into the evolution of the hot and dense matter created in Pb-Pb collisions. Starting from the physics motivations and working principles the challenges and current status of development is detailed.

  5. VHMPID: a new detector for the ALICE experiment at LHC

    CERN Document Server

    Agócs, A Gu; Barnaföldi, G G; Bellwied, R; Bencze, Gy; Berényi, D; Boldizsár, L; Cuautle, E; De Cataldo, G; Di Bari, D; Di Mauro, A; Dominguez, I; Futó, E; García, E; Hamar, G; Harris, J; Harton, A; Kovács, L; Lévai, P; Lipusz, Cs; Markert, C; Martinengo, P; Martinez, M I; Mastromarco, M; Mayani, D; Molnár, L; Nappi, E; Ortiz, A; Paić, G; Pastore, C; Patino, M E; Perini, D; Perrino, D; Peskov, V; Pinsky, L; Piuz, F; Pochybová, S; Smirnov, N; Song, J; Timmins, A; Varga, D; Vargas, A; Vergara, S; Volpe, G; Yi, J; Yoo, I K

    2011-01-01

    This article presents the basic idea of VHMPID, an upgrade detector for the ALICE experiment at LHC, CERN. The main goal of this detector is to extend the particle identification capabilities of ALICE to give more insight into the evolution of the hot and dense matter created in Pb-Pb collisions. Starting from the physics motivations and working principles the challenges and current status of development is detailed.

  6. Bento Boxes

    Science.gov (United States)

    Hasio, Cindy

    2010-01-01

    Bento boxes are common objects in Japanese culture, designed to hold enough lunch for one person. They have individual compartments and sometimes multiple tiers for rice, vegetables, and other side dishes. They are made of materials ranging from wood, cloth, aluminum, or plastic. In general, the greater the number of foods, the better the box is…

  7. Molecular diversity of thermophilic bacteria isolated from Pasinler hot spring (Erzurum, Turkey)

    OpenAIRE

    ADIGÜZEL, Ahmet; İNAN, Kadriye; ŞAHİN, Fikrettin; ARASOĞLU, Tulin; GÜLLÜCE, Medine

    2011-01-01

    The present study was conducted to determine the phenotypic and genotypic characterization of thermophilic bacteria isolated from Pasinler hot spring, Erzurum, Turkey. Fatty acid profiles, BOX PCR fingerprints, and 16S rDNA sequence data were used for the phenotypic and genotypic characterization of thermophilic bacteria. Totally 9 different bacterial strains were selected based on morphological, physiological, and biochemical tests. These strains were characterized by molecular tests includi...

  8. MUON DETECTORS: DT

    CERN Multimedia

    Marco Dallavalle

    2012-01-01

      Although the year 2012 is the third year without access to the chambers and the Front-End electronics, the fraction of good channels is still very high at 99.1% thanks also to the constant care provided by the on-site operation team. The downtime caused to CMS as a consequence of DT failures is to-date <2%. The intervention on the LV power supplies, which required a large number of CAEN modules (137 A3050, 13 A3100, and 3 MAO) to be removed from the detector, reworked and tested during this Year-End Technical Stop, can now, after a few months of stable operation of the LV, be declared to have solved once-and-for-all the persistent problem with the overheating LV Anderson connectors. Another piece of very good news is that measurements of the noise from single-hit rate outside the drift-time box as a function of the LHC luminosity show that the noise rate and distribution are consistent with expectations of the simulations in the Muon TDR, which have guided the detector design and constru...

  9. Glove box adaptation, installation and commissioning of an assembled modular type atomic absorption unit with GF atomizer

    International Nuclear Information System (INIS)

    Gupta, Santosh Kumar; Thulasidas, S.K.; Goyal, Neelam; Godbole, S.V.

    2013-09-01

    The report describes glove box adaptation of an in-house developed AAS unit with GF as atomization source for determination of trace metallic elements in Pu bearing samples. In order to replace the old Varian Techtron GF-AAS which was utilized for analysis of Pu bearing samples for the last thirty seven years, and as of late was giving too many practical problems, a new GF-AAS was designed and reassembled. The original compact flame AAS unit available with M/s. Thermo Fisher India Pvt. Ltd, Nashik, was converted into separated modular unit viz. Hollow Cathode Lamp unit, Atomizer unit and Monochromator - Detector - Readout unit. In addition, these modular units were modified with respect to their dimensions so as to enable their use with existing glove box facility developed earlier in 1980 for glove box incorporation. These units were separated from each other at their factory site so as to enable us to incorporate atomizer unit alone in the glove box. Glove box adapted GF-AAS is essential for Radiochemistry Division to provide analytical services to Chemical Quality Control of Pu bearing nuclear and related materials and also as an analytical support to the R and D activities of the Radiochemistry Division, BARC. (author)

  10. Hot Chemistry Laboratory decommissioning activities at IPEN/CNEN-SP, Brazil

    International Nuclear Information System (INIS)

    Camilo, Ruth L.; Lainetti, Paulo E.O.

    2009-01-01

    IPEN's fuel cycle activities were accomplished in laboratory and pilot plant scale and most facilities were built in the 70-80 years. Nevertheless, radical changes of the Brazilian nuclear policy in the beginning of 90's determined the interruption of several fuel cycle activities and facilities shutdown. Since then, IPEN has faced the problem of the pilot plants decommissioning considering that there was no experience/expertise in this field at all. In spite of this, some laboratory and pilot plant decommissioning activities have been performed in IPEN in the last years, even without previous experience and training support. One of the first decommissioning activities accomplished in IPEN involved the Hot Chemistry Laboratory. This facility was built in the beginning of the 80's with the proposal of supporting research and development in the nuclear chemistry area. It was decided to settle a new laboratory in the place where the Hot Chemistry Laboratory was installed, being necessary its total releasing from the radioactive contamination point of view. The previous work in the laboratory involved the manipulation of samples of irradiated nuclear fuel, besides plutonium-239 and uranium-233 standard solutions. There were 5 glove-boxes in the facility but only 3 were used with radioactive material. The glove-boxes contained several devices and materials, besides the radioactive compounds, such as: electric and electronic equipment, metallic and plastic pieces, chemical reagents, liquid and solid radioactive wastes, etc. The laboratory's decommissioning process was divided in 12 steps. This paper describes the procedures, problems faced and results related to the Hot Chemistry Laboratory decommissioning operations and its reintegration as a new laboratory of the Chemical and Environmental Technology Center (CQMA) - IPEN-CNEN/SP. (author)

  11. Changes in position and quality of preferred nest box: effects on nest box use by laying hens

    DEFF Research Database (Denmark)

    Riber, Anja Brinch; Nielsen, Birte L.

    2013-01-01

    Using laying hens, we investigated whether position of a nest box, both within the pen and relative to other nest boxes, influenced the preference for a nest box, and how a sudden and marked change to the preferred box influenced the use of nest boxes by the hens. Groups (n=12) of 15 Isa Warren...... hens were housed in pens, each with five identical nest boxes in different positions: Two single (in a corner or not) and a triplet of nest boxes (one of which in a corner). The use of nest boxes was determined by the number of eggs laid daily in each box. Three experiments, each lasting 10 days, were...... carried out. First, the undisturbed use of each of the nest box types was investigated, and a strong preference (Peggs laid there. Second, each of the hen groups was moved to another pen allocated at random, and where...

  12. [Boxing: traumatology and prevention].

    Science.gov (United States)

    Cabanis, Emmanuel-Alain; Iba-Zizen, Marie-Thérèse; Perez, Georges; Senegas, Xavier; Furgoni, Julien; Pineau, Jean-Claude; Louquet, Jean-Louis; Henrion, Roger

    2010-10-01

    In 1986, a surgeon who, as an amateur boxer himself was concerned with boxers' health, approached a pioneering Parisian neuroimaging unit. Thus began a study in close cooperation with the French Boxing Federation, spanning 25 years. In a first series of 52 volunteer boxers (13 amateurs and 39 professionals), during which MRI gradually replaced computed tomography, ten risk factors were identified, which notably included boxing style: only one of 40 "stylists" with a good boxing technique had cortical atrophy (4.5 %), compared to 15 % of "sloggers". Changes to the French Boxing Federation rules placed the accent on medical prevention. The second series, of 247 boxers (81 amateurs and 266 professionals), showed a clear improvement, as lesions were suspected in 14 individuals, of which only 4 (1.35 %) were probably due to boxing. The third and fourth series were part of a protocol called "Brain-Boxing-Ageing", which included 76 boxers (11 having suffered KOs) and 120 MRI scans, with reproducible CT and MRI acquisitions (9 sequences with 1.5 T then 3 T, and CT). MRI anomalies secondary to boxing were found in 11 % of amateurs and 38 % of professionals (atrophy, high vascular T2 signal areas, 2 cases of post-KO subdural bleeding). CT revealed sinus damage in 13 % of the amateurs and 19 % of the professionals. The risk of acute and chronic facial and brain damage was underline, along with detailed precautionary measures (organization of bouts, role of the referee and ringside doctor, and application of French Boxing Federation rules).

  13. Test of In-core Flux Detectors in KNK II

    CERN Document Server

    Hoppe, P

    1979-01-01

    The development of in-core detectors for Liquid Metal Fast Breeder Reactors (LMFBRs) is still in an early stage, and little operation experience is available. Therefore self-powered neutron and gamma detectors and neutron sensitive ionization chambers -especially developed for LMFBRs- have been tested in the Fast Sodium Cooled Test Reactor KNK II. Seven flux detectors have been installed in the core of KNK II by means of a special test rig. Five of them failed already within the first week during operation in the reactor. Due to measurements of electrical resistances and capacities, sodium penetrating into the detectors or cables probably seems to be the cause. As tests prior to the installation in the core proved the tightness of all detectors, it is suspected that small cracks have developed in the detector casings or in the outer cable sheaths during their exposure to the hot coolant. Two ionization chambers did not show these faults. However, one of them failed because the saturation current plateau disap...

  14. Time-resolved measurements of the hot-electron population in ignition-scale experiments on the National Ignition Facility (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Hohenberger, M., E-mail: mhoh@lle.rochester.edu; Stoeckl, C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); Albert, F.; Palmer, N. E.; Döppner, T.; Divol, L.; Dewald, E. L.; Bachmann, B.; MacPhee, A. G.; LaCaille, G.; Bradley, D. K. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Lee, J. J. [National Security Technologies LLC, Livermore, California 94551 (United States)

    2014-11-15

    In laser-driven inertial confinement fusion, hot electrons can preheat the fuel and prevent fusion-pellet compression to ignition conditions. Measuring the hot-electron population is key to designing an optimized ignition platform. The hot electrons in these high-intensity, laser-driven experiments, created via laser-plasma interactions, can be inferred from the bremsstrahlung generated by hot electrons interacting with the target. At the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 43, 2841 (2004)], the filter-fluorescer x-ray (FFLEX) diagnostic–a multichannel, hard x-ray spectrometer operating in the 20–500 keV range–has been upgraded to provide fully time-resolved, absolute measurements of the bremsstrahlung spectrum with ∼300 ps resolution. Initial time-resolved data exhibited significant background and low signal-to-noise ratio, leading to a redesign of the FFLEX housing and enhanced shielding around the detector. The FFLEX x-ray sensitivity was characterized with an absolutely calibrated, energy-dispersive high-purity germanium detector using the high-energy x-ray source at NSTec Livermore Operations over a range of K-shell fluorescence energies up to 111 keV (U K{sub β}). The detectors impulse response function was measured in situ on NIF short-pulse (∼90 ps) experiments, and in off-line tests.

  15. Microclimate boxes for panel paintings

    DEFF Research Database (Denmark)

    Wadum, Jørgen

    1998-01-01

    The use of microclimate boxes to protect vulnerable panel paintings is, therefore, not a new phenomenon of the past two or three decades. Rather, it has been a concern for conservators and curators to protect these objects of art at home and in transit since the end of the nineteenth century....... The increased number of travelling exhibitions in recent years has heightened the need to protect paintings during circulation (Thomson 1961; Mecklenburg 1991). The use and design of microclimate boxes have been evolving since 1892. These boxes may be divided into three broad groups: those using an active...... buffer material to stabilize the internal RH, a more recent box containing no added buffer material, and, in recent times, boxes with an altered gas content. Another concern is the appearance (aesthetics) of the box....

  16. Boxing-related head injuries.

    Science.gov (United States)

    Jayarao, Mayur; Chin, Lawrence S; Cantu, Robert C

    2010-10-01

    Fatalities in boxing are most often due to traumatic brain injury that occurs in the ring. In the past 30 years, significant improvements in ringside and medical equipment, safety, and regulations have resulted in a dramatic reduction in the fatality rate. Nonetheless, the rate of boxing-related head injuries, particularly concussions, remains unknown, due in large part to its variability in clinical presentation. Furthermore, the significance of repeat concussions sustained when boxing is just now being understood. In this article, we identify the clinical manifestations, pathophysiology, and management of boxing-related head injuries, and discuss preventive strategies to reduce head injuries sustained by boxers.

  17. Exergaming boxing versus heavy-bag boxing: are these equipotent for individuals with spinal cord injury?

    Science.gov (United States)

    Mat Rosly, Maziah; Mat Rosly, Hadi; Hasnan, Nazirah; Davis, Glen M; Husain, Ruby

    2017-08-01

    Current strategies for increased physical activity and exercise in individuals with spinal cord injury (SCI) face many challenges with regards to maintaining their continuity of participation. Barriers cited often include problems with accessing facilities, mundane, monotonous or boring exercises and expensive equipment that is often not adapted for wheelchair users. To compare the physiological responses and user preferences between conventional heavy-bag boxing against a novel form of video game boxing, known as exergaming boxing. Cross-sectional study. Exercise laboratory setting in a university medical center. Seventeen participants with SCI were recruited, of which sixteen were male and only one female. Their mean age was 35.6±10.2 years. All of them performed a 15-minute physical exercise session of exergaming and heavy-bag boxing in a sitting position. The study assessed physiological responses in terms of oxygen consumption, metabolic equivalent (MET) and energy expenditure between exergaming and heavy-bag boxing derived from open-circuit spirometry. Participants also rated their perceived exertion using Borg's category-ratio ratings of perceived exertion. Both exergaming (MET: 4.3±1.0) and heavy-bag boxing (MET: 4.4±1.0) achieved moderate exercise intensities in these participants with SCI. Paired t-test revealed no significant differences (P>0.05, Cohen's d: 0.02-0.49) in the physiological or perceived exertional responses between the two modalities of boxing. Post session user survey reported all the participants found exergaming boxing more enjoyable. Exergaming boxing, was able to produce equipotent physiological responses as conventional heavy-bag boxing. The intensity of both exercise modalities achieved recommended intensities for health and fitness benefits. Exergaming boxing have the potential to provide an enjoyable, self-competitive environment for moderate-vigorous exercise even at the comfort of their homes.

  18. LHCb Scintillating Fiber detector front end electronics design and quality assurance

    Science.gov (United States)

    Vink, W. E. W.; Pellegrino, A.; Ietswaard, G. C. M.; Verkooijen, J. C.; Carneiro, U.; Massefferi, A.

    2017-03-01

    The on-detector electronics of the LHCb Scintillating Fiber Detector consists of multiple PCBs assembled in a unit called Read Out Box, capable of reading out 2048 channels with an output rate of 70 Gbps. There are three types of boards: PACIFIC, Clusterization and Master Board. The Pacific Boards host PACIFIC ASICs, with pre-amplifier and comparator stages producing two bits of data per channel. A cluster-finding algorithm is then run in an FPGA on the Clusterization Board. The Master Board distributes fast and slow control, and power. We describe the design, production and test of prototype PCBs.

  19. Invariant box-parameterization of neutrino oscillations

    International Nuclear Information System (INIS)

    Weiler, Thomas J.; Wagner, DJ

    1998-01-01

    The model-independent 'box' parameterization of neutrino oscillations is examined. The invariant boxes are the classical amplitudes of the individual oscillating terms. Being observables, the boxes are independent of the choice of parameterization of the mixing matrix. Emphasis is placed on the relations among the box parameters due to mixing-matrix unitarity, and on the reduction of the number of boxes to the minimum basis set. Using the box algebra, we show that CP-violation may be inferred from measurements of neutrino flavor mixing even when the oscillatory factors have averaged. General analyses of neutrino oscillations among n≥3 flavors can readily determine the boxes, which can then be manipulated to yield magnitudes of mixing matrix elements

  20. First-aid boxes - Reminder

    CERN Multimedia

    GS Department

    2010-01-01

    With a view to ensuring optimum use of the first-aid boxes on the CERN site, we should like to remind you of various changes introduced in March 2009: The TSO of the buildings concerned is responsible for the first-aid boxes, including checking their contents.   First-aid boxes may be restocked ONLY at the CERN stores (SCEM No. 54.99.80). This is no longer possible at the Infirmary. The associated cost is charged to the Departments.   First-aid boxes should be used only for mild injuries. All other cases should be referred to the Medical Service Infirmary (Bldg. 57 – ground-floor, tel. 73802) between 8.00 a.m. and 5.30 p.m. or to the Fire and Rescue Service (tel. 74444). N.B.: This information does not apply to the red emergency first-aid boxes in the underground areas or to the emergency kits for use in the event of being splashed with hydrofluoric acid.

  1. Golden Jubilee photos: A New Class of Detectors

    CERN Multimedia

    2004-01-01

    In the 1960s, detection in particle physics mainly meant examining millions of photographs from bubble chambers or spark chambers. This was slow, labour intensive and not suitable for studies into rare phenomena, so there was a bottleneck that could have affected further progress in high energy physics. The transistor revolution triggered new ideas. While a camera could detect a spark, a detector wire connected to an amplifier could detect a much smaller effect. In 1968, Georges Charpak developed the 'multiwire proportional chamber', a gas-filled box with a large number of parallel detector wires, each connected to individual amplifiers. Linked to a computer, it could achieve a counting rate a thousand times better than existing techniques - without a camera in sight. Today practically every experiment in particle physics uses some type of track detector that is based on the principle of the multiwire proportional chamber. The technology is also used in many other fields using ionising radiation such as biol...

  2. Development of a compact 25-channel preamplifier module for Si-pad detectors of the BARC-CPDA

    International Nuclear Information System (INIS)

    Inkar, A.; John, Bency; Vind, R.P.; Kinage, L.; Jangale, R.V.; Biswas, D.C.; Nayak, B.K.

    2011-01-01

    The BARC Charged Particle Detector Array modules use indigenously developed Si pad detectors as their first element. Total number of charge sensitive pre-amplifiers required for the Si-pad detectors is 250. One of the main ideas here is a layout of five pre-amplifiers connected with one Si-pad detector (called a bank of preamplifiers). In the present work, a 25-channel pre-amplifier module that can cater to 5 independent Si-pad detectors, or a five-bank module, has been developed. This module uses pre-amp hybrid chips A1422H from CAEN S.p.A. and is housed in a double width NIM standard box. The module has been tested for performance using proton and ''7Li beams from FOTIA facility, Trombay

  3. Repackaging SRS Black Box TRU Waste

    International Nuclear Information System (INIS)

    Swale, D. J.; Stone, K.A.; Milner, T. N.

    2006-01-01

    Historically, large items of TRU Waste, which were too large to be packaged in drums for disposal have been packaged in various sizes of custom made plywood boxes at the Savannah River Site (SRS), for many years. These boxes were subsequently packaged into large steel ''Black Boxes'' for storage at SRS, pending availability of Characterization and Certification capability, to facilitate disposal of larger items of TRU Waste. There are approximately 107 Black Boxes in inventory at SRS, each measuring some 18' x 12' x 7', and weighing up to 45,000 lbs. These Black Boxes have been stored since the early 1980s. The project to repackage this waste into Standard Large Boxes (SLBs), Standard Waste Boxes (SWB) and Ten Drum Overpacks (TDOP), for subsequent characterization and WIPP disposal, commenced in FY04. To date, 10 Black Boxes have been repackaged, resulting in 40 SLB-2's, and 37 B25 overpack boxes, these B25's will be overpacked in SLB-2's prior to shipping to WIPP. This paper will describe experience to date from this project

  4. Invariant box parameterization of neutrino oscillations

    International Nuclear Information System (INIS)

    Weiler, T.J.; Wagner, D.

    1998-01-01

    The model-independent 'box' parameterization of neutrino oscillations is examined. The invariant boxes are the classical amplitudes of the individual oscillating terms. Being observables, the boxes are independent of the choice of parameterization of the mixing matrix. Emphasis is placed on the relations among the box parameters due to mixing matrix unitarity, and on the reduction of the number of boxes to the minimum basis set. Using the box algebra, we show that CP-violation may be inferred from measurements of neutrino flavor mixing even when the oscillatory factors have averaged. General analyses of neutrino oscillations among n≥3 flavors can readily determine the boxes, which can then be manipulated to yield magnitudes of mixing matrix elements. copyright 1998 American Institute of Physics

  5. Box-particle intensity filter

    OpenAIRE

    Schikora, Marek; Gning, Amadou; Mihaylova, Lyudmila; Cremers, Daniel; Koch, Wofgang; Streit, Roy

    2012-01-01

    This paper develops a novel approach for multi-target tracking, called box-particle intensity filter (box-iFilter). The approach is able to cope with unknown clutter, false alarms and estimates the unknown number of targets. Furthermore, it is capable of dealing with three sources of uncertainty: stochastic, set-theoretic and data association uncertainty. The box-iFilter reduces the number of particles significantly, which improves the runtime considerably. The low particle number enables thi...

  6. Molecular cloning and characterization of an F-box family gene CarF-box1 from chickpea (Cicer arietinum L.).

    Science.gov (United States)

    Jia, Yuying; Gu, Hanyan; Wang, Xiansheng; Chen, Quanjia; Shi, Shubing; Zhang, Jusong; Ma, Lin; Zhang, Hua; Ma, Hao

    2012-03-01

    F-box protein family has been found to play important roles in plant development and abiotic stress responses via the ubiquitin pathway. In this study, an F-box gene CarF-box1 (for Cicer arietinum F-box gene 1, Genbank accession no. GU247510) was isolated based on a cDNA library constructed with chickpea seedling leaves treated by polyethylene glycol. CarF-box1 encoded a putative protein with 345 amino acids and contained no intron within genomic DNA sequence. CarF-box1 is a KFB-type F-box protein, having a conserved F-box domain in the N-terminus and a Kelch repeat domain in the C-terminus. CarF-box1 was localized in the nucleus. CarF-box1 exhibited organ-specific expression and showed different expression patterns during seed development and germination processes, especially strongly expressed in the blooming flowers. In the leaves, CarF-box1 could be significantly induced by drought stress and slightly induced by IAA treatment, while in the roots, CarF-box1 could be strongly induced by drought, salinity and methyl jasmonate stresses. Our results suggest that CarF-box1 encodes an F-box protein and may be involved in various plant developmental processes and abiotic stress responses.

  7. LORINE: Neutron emission Locator by SOI detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hamrita, H.; Kondrasovs, V.; Borbotte, J. M.; Normand, S. [CEA, LIST, Laboratoire Capteurs et Architectures Electronique, F-91191 Gif-sur-Yvette Cedex (France); Saurel, N. [CEA, DAM, VALDUC, F-21120 Is sur Tille (France)

    2009-07-01

    The aim of this work is to develop a fast Neutron Emission Locator based on silicon on Insulator detector (LORINE). This locator can be used in the presence of significant flux of gamma radiation. LORINE was developed to locate areas containing a significant amount of actinide during the dismantling operations of equipment. From the results obtained in laboratory, we have proposed the prototype of neutron emission locator as follows: the developed design consists of 5 SOI (Silicon-on-insulator) detectors (1*1 cm{sup 2}) with their charge preamplifiers and their respective converters. All are installed on 5 faces of a boron polyethylene cube (5*5*5 cm{sup 3}). This cube plays the role of neutron shielding between the several detectors. The design must be so compact for use in glove boxes. An electronic card based on micro-controller has been made to control sensors and to send the necessary information to the computer. Location of fast neutron sources does not yet exist in a so compact design and it can be operated in the presence of very important gamma radiation flux

  8. A flexible system to capture sample vials in a storage box - the box vial scanner.

    Science.gov (United States)

    Nowakowski, Steven E; Kressin, Kenneth R; Deick, Steven D

    2009-01-01

    Tracking sample vials in a research environment is a critical task and doing so efficiently can have a large impact on productivity, especially in high volume laboratories. There are several challenges to automating the capture process, including the variety of containers used to store samples. We developed a fast and robust system to capture the location of sample vials being placed in storage that allows the laboratories the flexibility to use sample containers of varying dimensions. With a single scan, this device captures the box identifier, the vial identifier and the location of each vial within a freezer storage box. The sample vials are tracked through a barcode label affixed to the cap while the boxes are tracked by a barcode label on the side of the box. Scanning units are placed at the point of use and forward data to a sever application for processing the scanned data. Scanning units consist of an industrial barcode reader mounted in a fixture positioning the box for scanning and providing lighting during the scan. The server application transforms the scan data into a list of storage locations holding vial identifiers. The list is then transferred to the laboratory database. The box vial scanner captures the IDs and location information for an entire box of sample vials into the laboratory database in a single scan. The system accommodates a wide variety of vials sizes by inserting risers under the sample box and a variety of storage box layouts are supported via the processing algorithm on the server.

  9. Dimension measuring method for channel box

    International Nuclear Information System (INIS)

    Jo, Hiroto.

    1995-01-01

    The device of the present invention concerns detection of a channel box for spent fuel assemblies of a BWR type reactor, which measures a cross sectional shape and dimension of the channel box to check deformation amount such as expansion. That is, a customary fuel exchanger and a dimension measuring device are used. The lower end of the channel box is measured by a distance sensor of the dimension measuring device when it is aligned with a position of the distance sensor. The channel box is lowered at the same time while detecting axial position data of the fuel exchanger. The position of the channel box in an axial direction is detected based on axial position data of the fuel exchanger. The lower end of the channel box can accurately be recognized by the detection of both of them. Subsequent deformation measurement for the channel box at accurate axial positions is enabled. In addition, since the axial position data of the fuel exchanger per se are detected, an axial profile of the channel box can be measured even if a lifting speed of the channel box is varied on every region. (I.S.)

  10. Special Testing for Modules Deployed in Hot Use Environments - Are We Doing This in a Low-Cost Way?

    Energy Technology Data Exchange (ETDEWEB)

    Repins, Ingrid; Jordan, Dirk; Bosco, Nick; Flueckiger, Chris

    2016-09-12

    The proposed new IEC standard will address the test temperature requirements in IEC 61215 (module design), IEC 61730 (module safety), IEC 62790 (junction box safety) and IEC 62852 (connectors), and will provide guidelines to modify temperature limits in four existing standards to better describe module performance in hotter climates. This workshop includes four presentations: Special Testing for Modules Deployed in Hot Use Environments - Are We Doing This in a Low-Cost Way?, Experimental Evidence, Why the highest temperatures are the most stressful to PV modules during thermal cycling, and Safety Aspects for Modules Deployed in Hot Use Environments.

  11. Field study of alpha characterization of a D ampersand D site using long-range alpha detectors

    International Nuclear Information System (INIS)

    Rawool-Sullivan, M.W.; Allander, K.S.; Bounds, J.A.; Koster, J.E.; MacArthur, D.W.; Sprouse, L.L.; Stout, D.; Vaccarella, J.A.; Vu, T.Q.

    1994-01-01

    A successful and cost-effective D ampersand D effort relies upon an accurate, real-time, in situ, and non-destructive method of characterization of contamination both before and after the decontamination process. Detector systems based on long-range alpha detection (LRAD) technology meet these criteria. Currently, LANL is in the process of investigating, designing, or building various surface monitors, various pipe monitors, and glove-box monitors. This paper describes the field studies conducted using detectors based on LRAD technology

  12. Pungency Quantitation of Hot Pepper Sauces Using HPLC

    Science.gov (United States)

    Betts, Thomas A.

    1999-02-01

    A class of compounds known as capsaicinoids are responsible for the "heat" of hot peppers. To determine the pungency of a particular pepper or pepper product, one may quantify the capsaicinoids and relate those concentrations to the perceived heat. The format of the laboratory described here allows students to collectively develop an HPLC method for the quantitation of the two predominant capsaicinoids (capsaicin and dihydrocapsaicin) in hot-pepper products. Each small group of students investigated one of the following aspects of the method: detector wavelength, mobile-phase composition, extraction of capsaicinoids, calibration, and quantitation. The format of the lab forced students to communicate and cooperate to develop this method. The resulting HPLC method involves extraction with acetonitrile followed by solid-phase extraction clean-up, an isocratic 80:20 methanol-water mobile phase, a 4.6 mm by 25 cm C-18 column, and UV absorbance detection at 284 nm. The method developed by the students was then applied to the quantitation of capsaicinoids in a variety of hot pepper sauces. Editor's Note on Hazards in our April 2000 issue addresses the above.

  13. Measurements of streaming neutrons on nuclear ship 'Mutsu' by a two-detector-method

    International Nuclear Information System (INIS)

    Kobayashi, Iwao; Yamazaki, Hiroshi; Ryufuku, Hiroshi.

    1976-01-01

    Streaming neutrons escaping through an air gap located between the pressure vessel and the primary shield of the Nuclear Ship ''Mutsu'' were measured by applying the two-detector-method. The two detectors consisted of a single BF 3 counter provided alternatively with different covering arrangements - (a) 3mm thick steel tube + layers of polyethylene sheeting with total thickness of 30mm + 1mm thick Cd plate and (b) same covering as (a) + polyethylene boxing 20mm thick. In order to derive from the count rates obtained with the detectors described above the absolute values of neutron flux and dose equivalent rate, the detectors were calibrated in laboratory by comparison with a reference detector system in neutron field created around a 252 Cf source and TCA, a light-water moderated critical assembly. The conversion from measured counts to neutron flux and neutron dose equivalent rate was estimated to incur errors of +-15 and +-40%, respectively. (auth.)

  14. Heart Rate and Liking During "Kinect Boxing" Versus "Wii Boxing": The Potential for Enjoyable Vigorous Physical Activity Videogames.

    Science.gov (United States)

    Sanders, Gabriel J; Peacock, Corey A; Barkley, Jacob E; Gish, Brian; Brock, Scott; Volpenhein, Josh

    2015-08-01

    Nintendo(®) (Kyoto, Japan) "Wii™ Sports Boxing" ("Wii Boxing") and Xbox(®) (Microsoft, Redmond, WA) "Kinect(®) Sports Boxing" ("Kinect Boxing") are both boxing simulation videogames that are available for two different active videogame (AVG) systems. Although these AVGs are similar, the style of gameplay required is different (i.e., upper body only versus total body movements) and may alter physical activity intensity and one's preference for playing one game over the other. AVGs that elicit the greatest physiologic challenge and are preferred by users should be identified in an effort to enhance the efficacy of physical activity interventions and programs that include AVGs. The mean heart rate (HRmean) and peak heart rate (HRpeak) for 27 adults (22.7±4.2 years old) were recorded during four 10-minute conditions: seated rest, treadmill walking at 3 miles/hour, "Wii Boxing," and "Kinect Boxing." Upon completion of all four conditions, participants indicated which condition they preferred, and HRmean and HRpeak were calculated as a percentage of age-predicted maximum heart rate to classify physical activity intensity for the three activity conditions (treadmill, "Wii Boxing," and "Kinect Boxing"). "Kinect Boxing" significantly (P<0.001) increased percentage HRmean (64.1±1.6 percent of age-predicted maximum) and percentage HRpeak (76.5±1.9 percent) above all other conditions: Wii HRmean, 53.0±1.2 percent; Wii HRpeak, 61.8±1.5 percent; treadmill HRmean, 52.4±1.2 percent; treadmill HRpeak, 55.2±2.2 percent. Percentage HRpeak for "Kinect Boxing" was great enough to be considered a vigorous-intensity physical activity. There was no difference (P=0.55) in percentage HRmean between "Wii Boxing" and treadmill walking. Participants also preferred "Kinect Boxing" (P<0.001; n=26) to all other conditions ("Wii Boxing," n=1; treadmill n=0). "Kinect Boxing" was the most preferred and the only condition that was physiologically challenging enough to be classified as a

  15. Decommissioning of the Risoe Hot Cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1991-02-01

    The Hot Cell facility at Risoe has been in active use since 1964. During the years several types of nuclear fuels have been handled and examined: test reactor fuel pins from the Danish reactor DR3, the Norwegian Halden reactor, etc; power reactor fuel pins from several foreign reactors, including plutonium enriched pins; HTGR fuel from the Dragon reactor. All kinds of physical and chemical non-destructive and destructive post irradiation examinations have been performed. Besides, different radiotherapy sources have been produced, mainly cobalt sources. The general object of the decommissioning programme for the Hot Cell facility was to obtain a safe condition for the total building that does not require the special safety provisions. The hot cell building will be usable for other purposes after decommissioning. The facilicy comprised six concrete cells, lead cells, glove boxes, a shielded unit for temporary storage of waste, frogman area, decontamination areas, workshops, various installations of importance for safe operation of the plant, offices, etc. The tasks comprised e.g. removal of all irradiated fuel items, removal of other radioactive items, removal of contaminated equipment, and decontamination of all the cells and rooms. The goal was to decontaminate all the concrete cells to a degree where no loose contamination exists in the cells, and where the radiation level is so low, that total removal of the cell structures can be done at any time in the future without significant dose commitments. (AB)

  16. TT detector description and implementation of the survey measurements

    CERN Document Server

    Salzmann, C

    2008-01-01

    The TT geometry in the software has been updated to comply with the latest technical drawings. The main difference is in the description of the beam pipe insulation, where the amount of material has increased from $7.5\\%$ to $15.4\\%$ of $X_0$. Mother volumes are added to decrease the CPU consumption and finally several scans are made to compare the material budget between the DC06 geometry and the new 2008 geometry. In addition, the survey measurements of the TT detector have been analysed. These measurements can be subdivided into surveys of the detector box, photogrammetry of the balconies and metrology of the half-modules. The offsets with the nominal geometry are implemented in the alignment condition database.

  17. An Ultrasensitive Hot-Electron Bolometer for Low-Background SMM Applications

    Science.gov (United States)

    Olayaa, David; Wei, Jian; Pereverzev, Sergei; Karasik, Boris S.; Kawamura, Jonathan H.; McGrath, William R.; Sergeev, Andrei V.; Gershenson, Michael E.

    2006-01-01

    We are developing a hot-electron superconducting transition-edge sensor (TES) that is capable of counting THz photons and operates at T = 0.3K. The main driver for this work is moderate resolution spectroscopy (R approx. 1000) on the future space telescopes with cryogenically cooled (approx. 4 K) mirrors. The detectors for these telescopes must be background-limited with a noise equivalent power (NEP) approx. 10(exp -19)-10(exp -20) W/Hz(sup 1/2) over the range v = 0.3-10 THz. Above about 1 THz, the background photon arrival rate is expected to be approx. 10-100/s), and photon counting detectors may be preferable to an integrating type. We fabricated superconducting Ti nanosensors with a volume of approx. 3x10(exp -3) cubic microns on planar substrate and have measured the thermal conductance G to the thermal bath. A very low G = 4x10(exp -14) W/K, measured at 0.3 K, is due to the weak electron-phonon coupling in the material and the thermal isolation provided by superconducting Nb contacts. This low G corresponds to NEP(0.3K) = 3x10(exp -19) W/Hz(sup 1/2). This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with v > 0.3 THz at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range is approx. 50 dB.

  18. Construction and testing of the SLD Cerenkov ring imaging detector

    International Nuclear Information System (INIS)

    Cavalli-Sforza, M.; Coyle, P.; Coyne, D.; Gagnon, P.; Williams, D.A.; Abe, K.; Hasegawa, K.; Suekane, F.; Yuta, H.

    1990-01-01

    The authors report on the construction of the Cherenkov Ring Imaging Detector (CRID) for the SLD experiment at the SLAC Linear Collider and the testing of its components. The authors include results from testing the drift boxes, liquid radiator trays, and mirrors for the barrel CRID. The authors also discuss development of the support systems essential for the operation of the CRID: gas and liquid recirculator systems and monitoring

  19. The three-box paradox revisited

    International Nuclear Information System (INIS)

    Ravon, Tamar; Vaidman, Lev

    2007-01-01

    The classical three-box paradox of Kirkpatrick (2003 J. Phys. A: Math. Gen. 36 4891) is compared to the original quantum three-box paradox of Aharonov and Vaidman (1991 J. Phys. A: Math. Gen. 24 2315). It is argued that the quantum three-box experiment is a 'quantum paradox' in the sense that it is an example of a classical task which cannot be accomplished using classical means, but can be accomplished using quantum devices. It is shown that Kirkpatrick's card game is analogous to a different game with a particle in three boxes which does not contain paradoxical features

  20. IMPROVED, FAVORABLE FOR ENVIRONMENT POLYURETHANE COLD-BOX-PROCESS (COLD BOX «HUTTENES-ALBERTUS» .

    Directory of Open Access Journals (Sweden)

    A. Sergini

    2005-01-01

    Full Text Available The results of the laboratory and industrial investigations, the purpose of which is improvement of the classical Cold-box-process, i.e. the process of the slugs hardening in cold boxes, are presented.

  1. Reconciling White-Box and Black-Box Perspectives on Behavioral Self-adaptation

    DEFF Research Database (Denmark)

    Bruni, Roberto; Corradini, Andrea; Gadducci, Fabio

    2015-01-01

    This paper proposes to reconcile two perspectives on behavioral adaptation commonly taken at different stages of the engineering of autonomic computing systems. Requirements engineering activities often take a black-box perspective: A system is considered to be adaptive with respect to an environ......This paper proposes to reconcile two perspectives on behavioral adaptation commonly taken at different stages of the engineering of autonomic computing systems. Requirements engineering activities often take a black-box perspective: A system is considered to be adaptive with respect...... to an environment whenever the system is able to satisfy its goals irrespectively of the environment perturbations. Modeling and programming engineering activities often take a white-box perspective: A system is equipped with suitable adaptation mechanisms and its behavior is classified as adaptive depending...

  2. 324 and 325 Building Hot Cell Cleanout Program: Air lock cover block refurbishment

    International Nuclear Information System (INIS)

    Katayama, Y.B.; Holton, L.K. Jr.; Gale, R.M.

    1989-05-01

    The high-density concrete cover blocks shielding the pipe trench in the hot-cell air lock of the 324 Building Radiochemical Engineering Cells had accumulated fixed radioactivity ranging from 1100 to 22, 000 mrad/hr. A corresponding increase in the radiation exposure to personnel entering the air lock, together with ALARA concerns, led to the removal of the contaminated concrete surface with a hydraulic spaller and the emplacement of a stainless steel covering over a layer of grout. The resultant saving in radiation exposure is estimated to be 7200 mrad for personnel completing burial box runs for the 324 and 325 Building Hot Cell Cleanout Program. Radiation exposure to all staff members entering the air lock is now at least 50% lower. 3 refs., 22 figs., 1 tab

  3. Perancangan Prototipe Receiver Beacon Black Box Locator Acoustic 37,5 kHz Pingers

    Directory of Open Access Journals (Sweden)

    RUSTAMAJI RUSTAMAJI

    2016-01-01

    When an aircraft caught in an accident and crashes into the water, its location can be detected using a device called a receiver beacon black box locator acoustic (pingers receiver. The pingers receiver functioned as a reciever signal with 37,5 kHz ± 1 kHz frequency from trnasmitter pingers or Underwater Locator Beacon (ULB which is on air plane black blox. In this research made design pingers receiver composed of a series of  Band Pass Filter (BPF, envelope detector, audio amplifier, and loud speaker. The signal of 37,5 kHz ± 1 kHz  frequency sent by pingers transmitter will bereceived by pingers receiver, after which the signal will be processed by the Band Pass Filter (BPF circuit before being detected by envelope detector for take back the signal information which like pulse signal with 10ms width and 1 second interval as pingers signal tha can  be to  be heard by human ear. Based on the  design that  was made, the signal ouput generated by the prototype has a 14 ms width with 1 second interval. Keywords: pingers receiver, band pass filter (BPF, envelope detector, loud speaker.

  4. Decommissioning a small glove box

    International Nuclear Information System (INIS)

    Bond, R.D.; McSherry, K.

    1985-11-01

    An account is given of dismantling a fuel fabrication glove box using simple tooling. The fissile content of the box was first measured by several non-destructive techniques. After cleaning, the box was dismantled using hand tools and finally packed for disposal. A record of operator radiation doses, the time taken for each stage of the operation and packing information is given. (author)

  5. Research and development of a beta skin-dose monitor using silicon detectors

    International Nuclear Information System (INIS)

    Chung Manho.

    1991-01-01

    The purpose of the research is to develop improved ways to computer and measure the beta skin dose. Beta spectra for the various sources were calculated based on the Fermi beta decay theory. The calculated average energies of the spectra agreed with the literature values within 6%. Monte Carlo electron transport codes have been developed for use on microcomputers. The one-dimensional code ZEBRA has been converted to a microcomputer version called Eltran2 which runs on the Macintosh or any IBM compatible microcomputers. Eltran2 has then been modified into a two-dimensional program called Eltran3. Using Eltran2 and Eltran3, different source distributions and the hot particle dose have been studied. It has been found that the VARSKIN code overestimates the skin dose from hot particles by about 10 to 40% in comparison with Eltran3 calculations, because the VARSKIN code is based on the data tables for an unbounded medium. An ion-implanted silicon detector was selected because of its small size, high sensitivity, and low leakage current. To cover a wide range of dose rate, both the pulse and current mode operations of the silicon detector were used, with an overlap of one order of magnitude in the measurable dose rate ranges. By using a gradient shield of about 7 mg/cm 2 on the detector, dose gradient measurements have been performed. Five 60 Co hot particles received from GPU Nuclear Corporation have been measured by the silicon detector and the measurements agreed well with Eltran3 calculations. In the pulse mode, variation of the depletion depth of the silicon detector due to the changes of bias voltage was confirmed. Based on this research, a prototype beta skin dose monitor has been constructed. The device includes an 8-bit analogue-to-digital converter and a Z-80 microprocessor with a machine-coded program, to calculate the skin dose

  6. Study and realization of a far infrared radiation detector

    International Nuclear Information System (INIS)

    Pereira, Daniel

    1985-01-01

    A F.I.R. dadiation detector (lambda = 337 μm) which makes use of the hot electron photoconductivity in InSb is described. The InSb crystal is cut in a special shape which allows high resistance (-7 KΩ) at liquid helium temperature without a magnetic field. In this way the detector can be used in the optimum point of the noise figure with a ultra-low noise pre-amplifier. A study is done to determine the sensitivity and the NEP (optical and electrical) which results respectively in 70 V/W and 10 -10 WHz sup(-1/2) for optical parameters. (Author) [pt

  7. Hot Deformation Behavior of Hot-Extruded AA7175 Through Hot Torsion Tests.

    Science.gov (United States)

    Lee, Se-Yeon; Jung, Taek-Kyun; Son, Hyeon-Woo; Kim, Sang-Wook; Son, Kwang-Tae; Choi, Ho-Joon; Oh, Sang-Ho; Lee, Ji-Woon; Hyun, Soong-Keun

    2018-03-01

    The hot deformation behavior of hot-extruded AA7175 was investigated with flow curves and processing maps through hot torsion tests. The flow curves and the deformed microstructures revealed that dynamic recrystallization (DRX) occurred in the hot-extruded AA7175 during hot working. The failure strain was highest at medium temperature. This was mainly influenced by the dynamic precipitation of fine rod-shaped MgZn2. The processing map determined the optimal deformation condition for the alloy during hot working.

  8. A Preliminary Shielding Study on the Integrated Operation Verification System in the Head-End Hot-Cell of the Pyro-processing

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jinhwam; Kim, Yewon; Park, Se-Hwan; Ahn, Seong-Kyu; Cho, Gyuseong [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    Nuclear power accounts for more than 30 percent of power production in Korea. Its significance has annually been increased. Disposal spent fuel containing uranium, transuranic elements, and fission products is unavoidable byproduct of nuclear power production. it is recognized that finding appropriate sites for interim storage of disposal spent fuel is not easy because isolated sites should be required. Pyro-processing technology, Pyro-processing should be operated under high radiation environment in hot-cell structures. Because of this reason, all workers should be unauthorized to access inside the hot-cell areas under any circumstances except for acceptable dose verification and a normal operation should be remotely manipulated. For the reliable normal operation of pyroprocessing, it is noted that an evaluation of the space dose distribution in the hot-cell environments is necessary in advance in order to determine which technologies or instruments can be utilized on or near the process as the Integrated Operation Verification System (IOVS) is measured. Not like the electroreduction and electro-refining hot-cells, the head-end hot-cell equips Camera Radiation Detector (CRD) in which plutonium is securely measured and monitored for the safeguard of the pyro-processing. Results have been obtained using F2 surface tally in order to observe the magnitude of the gamma-ray and neutron flux which pass through the surface of the process cell. Furthermore, T-mesh tally has also been used to obtain the space dose distribution in the headend hot-cell. The hot-cell was divided into 7,668 cells in which each dimension was 1 x 1 x 1m for the T-mesh tally. To determine the position of the CRD and the surveillance camera, divergent approaches were required. Because the purpose of the CRD which contains a gamma-ray detector and a neutron detector is to identify the material composition as the process proceeds, the position in which detectable flux is exposed is required, whereas

  9. Measurements of hot electrons in the Extrap T1 reversed-field pinch

    International Nuclear Information System (INIS)

    Welander, A.; Bergsaaker, H.

    1998-01-01

    The presence of an anisotropic energetic electron population in the edge region is a characteristic feature of reversed-field pinch (RFP) plasmas. In the Extrap T1 RFP, the anisotropic, parallel heat flux in the edge region measured by calorimetry was typically several hundred MWm -2 . To gain more insight into the origin of the hot electron component and to achieve time resolution of the hot electron flow during the discharge, a target probe with a soft x-ray monitor was designed, calibrated and implemented. The x-ray emission from the target was measured with a surface barrier detector covered with a set of different x-ray filters to achieve energy resolution. A calibration in the range 0.5-2 keV electron energy was performed on the same target and detector assembly using a LaB 6 cathode electron gun. The calibration data are interpolated and extrapolated numerically. A directional asymmetry of more than a factor of 100 for the higher energy electrons is observed. The hot electrons are estimated to constitute 10% of the total electron density at the edge and their energy distribution is approximated by a half-Maxwellian with a temperature slightly higher than the central electron temperature. Scalings with plasma current, as well as correlations with local Hα measurements and radial dependences, are presented. (author)

  10. Box-particle probability hypothesis density filtering

    OpenAIRE

    Schikora, M.; Gning, A.; Mihaylova, L.; Cremers, D.; Koch, W.

    2014-01-01

    This paper develops a novel approach for multitarget tracking, called box-particle probability hypothesis density filter (box-PHD filter). The approach is able to track multiple targets and estimates the unknown number of targets. Furthermore, it is capable of dealing with three sources of uncertainty: stochastic, set-theoretic, and data association uncertainty. The box-PHD filter reduces the number of particles significantly, which improves the runtime considerably. The small number of box-p...

  11. The visibility of using water boxes and mulch in dryland revegetation

    Science.gov (United States)

    Alhamad, Mohammad Noor; Alrababah, Mohammad; Athamneh, Hanaa

    2017-04-01

    Drylands cover more than 41% of the world's surface area and are homeland for about one-third of the world's population, 90% of them in developing countries. Land degradation in the drylands is hot environmental topic as it impacts environmental quality and jeopardizes food security in developing countries. The climate of Jordan varies from dry sub-humid Mediterranean in northwestern areas to desert conditions over a distance of 100 km, where more than 90 % of the county's area receives annual rainfall of less than 200 mm. In Jordan revegetation programs are rainfed; rainfall in Jordan is characterized by variable nature, thus, these programs faces a major challenge of the low survival rate of transplanted seedlings. The present study ought to explore the visibility of using water boxes and plastic mulch as an innovative approach to enhance seedling survival and establishment of four forest tress species ( Carob, Cupressus, Quercus, and Pinus). The experiment results showed that Cupressus, and Pinus seedlings expressed the highest survival rate of 88% and 84 % respectively, flowed by Crob (64%) and Querrcus (16%). The plastic mulch significantly enhanced the seedling survival rate b y40 % over the control while the water boxes resulted in an increase of 32 % over the control.

  12. Channel box dimension measuring method

    International Nuclear Information System (INIS)

    Oshima, Hirotake; Jo, Hiroto.

    1994-01-01

    The present invention provides a method for measuring the entire length of a channel box of a fuel assembly of a BWR type reactor. Namely, four sensors are used as one set that generate ultrasonic waves from oblique upper portion, oblique lower portion, upper portion and lower portion of the channel box respectively. The distances between the four sensors and each of the portions of the channel box are measured respectively for both of a reference member and a member to be measured. The entire length of the channel box is measured by calculating the measured values and the angles of the obliquely disposed sensors according to a predetermined formula. According to the method of the present invention, the inclination of the channel box to be measured can be corrected. In addition, accuracy of the measurement is improved and the measuring time is saved as well as the measuring device and operation can be simplified. (I.S.)

  13. Test of In-core Flux Detectors in KNK II

    International Nuclear Information System (INIS)

    Hoppe, P.; Mitzel, F.

    1979-10-01

    The development of in-core detectors for Liquid Metal Fast Breeder Reactors (LMFBRs) is still in an early stage, and little operation experience is available. Therefore self-powered neutron and gamma detectors and neutron sensitive ionization chambers -especially developed for LMFBRs- have been tested in the Fast Sodium Cooled Test Reactor KNK II. Seven flux detectors have been installed in the core of KNK II by means of a special test rig. Five of them failed already within the first week during operation in the reactor. Due to measurements of electrical resistances and capacities, sodium penetrating into the detectors or cables probably seems to be the cause. As tests prior to the installation in the core proved the tightness of all detectors, it is suspected that small cracks have developed in the detector casings or in the outer cable sheaths during their exposure to the hot coolant. Two ionization chambers did not show these faults. However, one of them failed because the saturation current plateau disappeared and the other one's sensitivity decreased by a factor of five during the test period. It is suspected that in both cases changes of the filling gas might be involved

  14. Shaping 3-D boxes

    DEFF Research Database (Denmark)

    Stenholt, Rasmus; Madsen, Claus B.

    2011-01-01

    Enabling users to shape 3-D boxes in immersive virtual environments is a non-trivial problem. In this paper, a new family of techniques for creating rectangular boxes of arbitrary position, orientation, and size is presented and evaluated. These new techniques are based solely on position data...

  15. The SLD Cerenkov Ring Imaging Detector: Progress report

    International Nuclear Information System (INIS)

    Ashford, V.; Bienz, T.; Bird, F.

    1986-10-01

    We describe test beam results from a prototype Cerenkov Ring Imaging Detector (CRID) for the SLD experiment at the SLAC Linear Collider (SLC). The system includes both liquid and gas radiators, a long drift box containing gaseous TMAE and a proportional wire chamber with charge division readout. Measurements of the multiplicity and detection resolution of Cerenkov photons, from both radiators are presented. Various design aspects of a new engineering prototype, currently under construction, are discussed and recent R and D results relevant to this effort are reported

  16. Optimization of high pressure machine decocting process for Dachengqi Tang using HPLC fingerprints combined with the Box-Behnken experimental design.

    Science.gov (United States)

    Xie, Rui-Fang; Shi, Zhi-Na; Li, Zhi-Cheng; Chen, Pei-Pei; Li, Yi-Min; Zhou, Xin

    2015-04-01

    Using Dachengqi Tang (DCQT) as a model, high performance liquid chromatography (HPLC) fingerprints were applied to optimize machine extracting process with the Box-Behnken experimental design. HPLC fingerprints were carried out to investigate the chemical ingredients of DCQT; synthetic weighing method based on analytic hierarchy process (AHP) and criteria importance through intercriteria correlation (CRITIC) was performed to calculate synthetic scores of fingerprints; using the mark ingredients contents and synthetic scores as indicators, the Box-Behnken design was carried out to optimize the process parameters of machine decocting process under high pressure for DCQT. Results of optimal process showed that the herb materials were soaked for 45 min and extracted with 9 folds volume of water in the decocting machine under the temperature of 140 °C till the pressure arrived at 0.25 MPa; then hot decoction was excreted to soak Dahuang and Mangxiao for 5 min. Finally, obtained solutions were mixed, filtrated and packed. It concluded that HPLC fingerprints combined with the Box-Behnken experimental design could be used to optimize extracting process of traditional Chinese medicine (TCM).

  17. DUMAND-II (Deep Underwater Muon and Neutrino Detector) PROGRESS Report

    OpenAIRE

    Young, Kenneth K.

    1994-01-01

    The DUMAND-II detector will search for astronomical sources of high energy neutrinos. Successful deployment of the basic infrastructure, including the shore cable, the underwater junction box, and an environmental module was accomplished in December, 1993. One optical module string was also deployed and operated, logging data for about 10 hours. The underwater cable was connected to the shore station where we were able to successfully exercise system controls and log further environmental dat...

  18. Amorphous selenium based detectors for medical imaging applications

    Science.gov (United States)

    Mandal, Krishna C.; Kang, Sung H.; Choi, Michael; Jellison, Gerald E., Jr.

    2006-08-01

    We have developed and characterized large volume amorphous (a-) selenium (Se) stabilized alloys for room temperature medical imaging devices and high-energy physics detectors. The synthesis and preparation of well-defined and high quality a-Se (B, As, Cl) alloy materials have been conducted using a specially designed alloying reactor at EIC and installed in an argon atmosphere glove box. The alloy composition has been precisely controlled and optimized to ensure good device performance. The synthesis of large volume boron (B) doped (natural and isotopic 10B) a-Se (As, Cl) alloys has been carried out by thoroughly mixing vacuum distilled and zone-refined (ZR) Se with previously synthesized Se-As master alloys, Se-Cl master alloys and B. The synthesized a-Se (B, As, Cl) alloys have been characterized by x-ray diffraction (XRD), differential scanning calorimetry (DSC), Fourier transform infra-red spectroscopy (FTIR), x-ray photoelectron spectroscopy (XPS), inductively coupled plasma mass spectroscopy (ICP-MS), and detector testing. The a- Se alloys have shown high promise for x-ray detectors with its high dark resistivity (10 10-10 13 Ωcm), good charge transport properties, and cost-effective large area scalability. Details of various steps about detector fabrication and testing of these imaging devices are also presented.

  19. Complementarity in the Einstein-Bohr photon box

    NARCIS (Netherlands)

    Dieks, D.G.B.J.; Lam, S

    2008-01-01

    The Bohr-Einstein photon box thought experiment is a forerunner of the EPR experiment: a packet of radiation escapes from a box, and the box-plus-radiation state remains entangled. Hence, a measurement on the box makes a difference for the state of the far-away radiation long after its escape. This

  20. Superconducting NbN detectors for synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Semenov, Alexei; Richter, Heiko; Huebers, Heinz-Wilhelm [DLR, Instiute of Planetary Research, Berlin (Germany); Ilin, Konstantin; Siegel, Michael [Institute of Micro- and Nanoelectronic Systems, University of Karlsruhe (Germany)

    2009-07-01

    We present development of a special type of hot-electron bolometers that is designed to optimally detect pulsed synchrotron radiation in the terahertz frequency range. The enlarged log-spiral antenna makes it possible to sense the low-frequency part of the spectrum in coherent and non-coherent regime. The device follows the layout of a typical HEB mixer. The radiation is coupled quasioptically with the 6-mm elliptical silicon lens. The bolometer has the noise equivalent power 2 nW per square root Hz and responds to a few picoseconds long radiation pulse with the electric pulse having full width at half maximum of 160 ps. We present results obtained with this type of detector at different synchrotron facilities and discuss possible improvements of the detector performance.

  1. Dustproof cooling of the electrical box

    Directory of Open Access Journals (Sweden)

    Nemec Patrik

    2018-01-01

    Full Text Available In present are electrical boxes cooled by air through the intake hole on the bottom electrical box to the box space with electrotechnical elements and exhaust through the hole at the top to the surrounding by natural convection. This cooling method is effective but operate with the risk of contamination electrotechnical elements by dust sucking from surrounding air. The goal of this work is solution of the dustproof cooling of the electrical box by natural convection. The work deal with design of the device with the heat transfer by the phase change of the working fluid and experimental measuring its thermal performance at the cooling electrotechnical elements loaded by heat 1 200 W in the dustproof electrical box.

  2. Box graphs and resolutions I

    Directory of Open Access Journals (Sweden)

    Andreas P. Braun

    2016-04-01

    Full Text Available Box graphs succinctly and comprehensively characterize singular fibers of elliptic fibrations in codimension two and three, as well as flop transitions connecting these, in terms of representation theoretic data. We develop a framework that provides a systematic map between a box graph and a crepant algebraic resolution of the singular elliptic fibration, thus allowing an explicit construction of the fibers from a singular Weierstrass or Tate model. The key tool is what we call a fiber face diagram, which shows the relevant information of a (partial toric triangulation and allows the inclusion of more general algebraic blowups. We shown that each such diagram defines a sequence of weighted algebraic blowups, thus providing a realization of the fiber defined by the box graph in terms of an explicit resolution. We show this correspondence explicitly for the case of SU(5 by providing a map between box graphs and fiber faces, and thereby a sequence of algebraic resolutions of the Tate model, which realizes each of the box graphs.

  3. Plate forming and break down pizza box

    Science.gov (United States)

    Pantisano, Frank; Devine, Scott M.

    1992-01-01

    A standard corrugated paper pizza box is provided with slit cuts cut through the top panel of the pizza box in a shape to form four circular serving plates with a beveled raised edge and cross slit cuts through the bottom panel of the pizza box separating the box into four essentially equal portions for easy disposal.

  4. Influence of the geometrical characteristics of an HpGe detector on its efficiency

    International Nuclear Information System (INIS)

    Vargas, M.J.; Timon, A.F.; Sanchez, D.P.

    2002-01-01

    Computer codes based on Monte Carlo calculations have been extensively developed for the computation of the efficiency in gamma-ray spectrometry. The errors in the specific parameters of the detector due to the lack of precise knowledge of its characteristics usually represent one of the most important sources of inaccuracy in this simulation technique. Influence of several detector parameters on the efficiency for a typical coaxial n-type HpGe detector is presented. Calculations of the full-energy peak efficiencies were performed by means of a Monte Carlo code in the range 122-1836 keV for several types of source configuration: point source, cellulose filter, and two different cylindrical boxes containing a solid matrix of SiO 2 . The detector parameters varied were the crystal diameter, crystal height, diameter of the internal core, and the position of the crystal with respect to the beryllium window. Significant deviations in the efficiency, depending on the source geometry and the photon energy, can be produced by varying only slightly some of the detector parameters. (author)

  5. A Hot-electron Direct Detector for Radioastronomy

    Science.gov (United States)

    Karasik, B. S.; McGrath, W. R.; LeDuc, H. G.

    2000-01-01

    A new approach is proposed to improve the sensitivity of direct-detection bolometers. The idea is to adjust a speed of the thermal relaxation of hot-electrons in a nanometer size normal metal or superconductive transition edge bolometer by controlling the elastic electron mean free path. If the bolometer contacts are made of a superconductor with high critical temperature then the thermal diffusion into the contacts is absent because of the Andreev's reflection and the electron-phonon relaxation is the only mechanism for heat removal. The relaxation rate should behave as 7(exp 4)l at subkelvin temperatures (l is the electron elastic mean free path) and can be reduced by factor of 10 - 100 by decreasing l. Then an antenna- or waveguide-coupled bolometer with a time constant approx. 10(exp -3) to 10(exp -5) S at T approx. = 0.1 - 0.3 K will exhibit photon-noise limited performance in millimeter and subn-millimeter range. The bolometer will have a figure-of-merit NEk square root of tau approx. = 10(exp -22) 10(exp -21) W/Hz at 100 mK which is 10(exp 3) times smaller than that of a state-of-the-art bolometer. This will allow for a tremendous increase in speed which will have a significant impact for observational mapping applications. Alternatively, the bolometer could operate at higher temperature with still superior sensitivity This research was performed by the Center for Space Microelectronics Technology, JPL, California Institute of Technology, under the contract for NASA.

  6. Internal pair decay of giant resonances- signature from ISGMR in hot and heavy nucleus?

    International Nuclear Information System (INIS)

    Banerjee, S.R.

    1996-01-01

    The experimental observation of isoscalar giant monopole resonance built on highly excited nuclear states is still eluding the experimental nuclear physicists although a lot of effort has been put into it. Two very highly sophisticated specific detector systems had been constructed for this study and intense experimental activities were indulged in. Stony Brook pair detector array is being augmented currently to cover about 60% solid angle. There will be another spate of experimental activities and new results will be coming in, but presently there is no experimental observation of ISGMR in hot nucleus

  7. The Heuristic Interpretation of Box Plots

    Science.gov (United States)

    Lem, Stephanie; Onghena, Patrick; Verschaffel, Lieven; Van Dooren, Wim

    2013-01-01

    Box plots are frequently used, but are often misinterpreted by students. Especially the area of the box in box plots is often misinterpreted as representing number or proportion of observations, while it actually represents their density. In a first study, reaction time evidence was used to test whether heuristic reasoning underlies this…

  8. Repetitive box lifting performance is impaired in a hot environment: implications for altered work-rest cycles.

    Science.gov (United States)

    Maresh, Carl M; Sökmen, Bulent; Armstrong, Lawrence E; Dias, Joao C; Pryor, J Luke; Creighton, Brent C; Muñoz, Colleen X; Apicella, Jenna M; Casa, Douglas J; Lee, Elaine C; Anderson, Jeffery M; Kraemer, William J

    2014-01-01

    This study investigated the effects of environmental temperature on repetitive box lifting (RBL) performance, associated stress hormone and creatine kinase (CK) responses. Ten healthy males performed two experimental trials in a random crossover design. The trials consisted of three 40 min (10 min sitting, 20 min standing, and 10 min RBL) circuits performed in either 23 °C or 38 °C followed by a 180 min seated recovery period in 23 °C. RBL performance (i.e., number of boxes lifted) was reduced (p ≤ 0.05) in 38 °C compared to the 23 °C trial. Physiological Strain Index was significantly different between trials (38 °C: 8.5 ± 1.1 versus 23 °C: 7.2 ± 0.7; p ≤ 0.01). Plasma testosterone was elevated (p ≤ 0.05) across both trials and then decreased at 60 min recovery, compared to pre-exercise (PRE) measures, but was higher (p ≤ 0.05) during the 38 °C trial. Plasma cortisol increased (p ≤ 0.05) at 60 min during both trials and remained elevated until 120 min in 23 °C, and until 60 min recovery in 38 °C. Serum CK was greater through 48 hr post compared to PRE values in both trials. Thus, 10 min RBL performance was reduced in 38 °C despite the 30-min rest periods between RBL intervals. Plasma testosterone and cortisol were generally higher during the 38 °C trial, suggesting a greater stress response. Additional research is needed to determine optimal work:rest cycles for maximizing work performance in thermally oppressive environments.

  9. Injury risk in professional boxing.

    Science.gov (United States)

    Bledsoe, Gregory H; Li, Guohu; Levy, Fred

    2005-10-01

    Although a popular endeavor, boxing has fallen under increased scrutiny because of its association with traumatic brain injury. However, few studies have investigated the overall epidemiology of boxing injuries from representative samples, and no study has ever documented the incidence of injuries in female boxers. This study is a review of professional boxing data from the state of Nevada from September 2001 through March 2003. Medical and outcome data for all professional boxing matches occurring in Nevada between September 2001 and March 2003 (n = 524 matches) were analyzed on the basis of a pair-matched, case-control design. Cases were boxers who received an injury during the boxing matches. Boxers who were not injured served as control subjects. Both conditional and unconditional logistic regression models were used to assess risk factors for injury. The overall incidence rate of injury was 17.1 per 100 boxer-matches, or 3.4 per 100 boxer-rounds. Facial laceration accounted for 51% of all injuries, followed by hand injury (17%), eye injury (14%), and nose injury (5%). Male boxers were significantly more likely than female boxers to receive injuries (3.6 versus 1.2 per 100 boxer-rounds, P = 0.01). Male boxing matches also ended in knockouts and technical knockouts more often than did female matches (P boxing matches is high, particularly among male boxers. Superficial facial lacerations are the most common injury reported. Male boxers have a higher rate of knockout and technical knockouts than female boxers. Further research is necessary to determine the outcomes of injury, particularly the long-term neurologic outcome differences between sexes.

  10. Comparative Human and Automatic Evaluation of Glass-Box and Black-Box Approaches to Interactive Translation Prediction

    Directory of Open Access Journals (Sweden)

    Torregrosa Daniel

    2017-06-01

    Full Text Available Interactive translation prediction (ITP is a modality of computer-aided translation that assists professional translators by offering context-based computer-generated continuation suggestions as they type. While most state-of-the-art ITP systems follow a glass-box approach, meaning that they are tightly coupled to an adapted machine translation system, a black-box approach which does not need access to the inner workings of the bilingual resources used to generate the suggestions has been recently proposed in the literature: this new approach allows new sources of bilingual information to be included almost seamlessly. In this paper, we compare for the first time the glass-box and the black-box approaches by means of an automatic evaluation of translation tasks between related languages such as English–Spanish and unrelated ones such as Arabic–English and English–Chinese, showing that, with our setup, 20%–50% of keystrokes could be saved using either method and that the black-box approach outperformed the glass-box one in five out of six scenarios operating under similar conditions. We also performed a preliminary human evaluation of English to Spanish translation for both approaches. On average, the evaluators saved 10% keystrokes and were 4% faster with the black-box approach, and saved 15% keystrokes and were 12% slower with the glass-box one; but they could have saved 51% and 69% keystrokes respectively if they had used all the compatible suggestions. Users felt the suggestions helped them to translate faster and easier. All the tools used to perform the evaluation are available as free/open–source software.

  11. Effective and cheap X-ray television detector

    International Nuclear Information System (INIS)

    Artem'ev, A.N.; Potlovskij, K.G.; Rezvov, V.A.; Yudin, L.I.

    2002-01-01

    The position sensitive detector (PSD) is designed for investigations with traditional X-ray tubes and synchrotron radiation from 3 to 30 keV. PSD consists of light-tight box, which transforms X-ray photons to light photons. Light photons are registered with the help of TV camera. Then an image is digitized and introduced into computer. Software provides registration of the dim beam images by means of accumulation of the information. Statistic processing of the image series allows to determine of the parameters of the image. Sensitivity is 41 phot/pixel. Spatial resolution is not worse then 400 μ [ru

  12. Math in the Box

    Science.gov (United States)

    DeYoung, Mary J.

    2009-01-01

    This article describes how to make an origami paper box and explores the algebra, geometry, and other mathematics that unfolds. A set of origami steps that transforms the paper into an open box can hold mathematical surprises for both students and teachers. An origami lesson can engage students in an open-ended exploration of the relationship…

  13. ALUMINUM BOX BUNDLING PRESS

    Directory of Open Access Journals (Sweden)

    Iosif DUMITRESCU

    2015-05-01

    Full Text Available In municipal solid waste, aluminum is the main nonferrous metal, approximately 80- 85% of the total nonferrous metals. The income per ton gained from aluminum recuperation is 20 times higher than from glass, steel boxes or paper recuperation. The object of this paper is the design of a 300 kN press for aluminum box bundling.

  14. Design and properties of silicon charged-particle detectors developed at the Institute of Electron Technology (ITE)

    Science.gov (United States)

    Wegrzecki, Maciej; Bar, Jan; Budzyński, Tadeusz; CieŻ, Michal; Grabiec, Piotr; Kozłowski, Roman; Kulawik, Jan; Panas, Andrzej; Sarnecki, Jerzy; Słysz, Wojciech; Szmigiel, Dariusz; Wegrzecka, Iwona; Wielunski, Marek; Witek, Krzysztof; Yakushev, Alexander; Zaborowski, Michał

    2013-07-01

    The paper discusses the design of charged-particle detectors commissioned and developed at the Institute of Electron Technology (ITE) in collaboration with foreign partners, used in international research on transactinide elements and to build personal radiation protection devices in Germany. Properties of these detectors and the results obtained using the devices are also presented. The design of the following epiplanar detector structures is discussed: ♢ 64-element chromatographic arrays for the COMPACT (Cryo On-line Multidetector for Physics And Chemistry of Transactinides) detection system used at the GSI Helmholtzzentrum für Schwerionenforschung in Darmstadt (GSI) for research on Hassium, Copernicium and Flerovium, as well as elements 119 and 120, ♢ 2-element flow detectors for the COLD (Cryo On-Line Detector) system used for research on Copernicium and Flerovium at the Joint Institute for Nuclear Research, Dubna, ♢ detectors for a radon exposimeter and sensors for a neutron dosimeter developed at the Institut für Strahlenschutz, Helmholtz Zentrum München. The design of planar detectors - single-sided and double-sided strip detectors for the Focal Plane Detector Box used at GSI for research on Flerovium and elements 119 and 120 is also discussed.

  15. Box-Cox transformation for QTL mapping.

    Science.gov (United States)

    Yang, Runqing; Yi, Nengjun; Xu, Shizhong

    2006-01-01

    The maximum likelihood method of QTL mapping assumes that the phenotypic values of a quantitative trait follow a normal distribution. If the assumption is violated, some forms of transformation should be taken to make the assumption approximately true. The Box-Cox transformation is a general transformation method which can be applied to many different types of data. The flexibility of the Box-Cox transformation is due to a variable, called transformation factor, appearing in the Box-Cox formula. We developed a maximum likelihood method that treats the transformation factor as an unknown parameter, which is estimated from the data simultaneously along with the QTL parameters. The method makes an objective choice of data transformation and thus can be applied to QTL analysis for many different types of data. Simulation studies show that (1) Box-Cox transformation can substantially increase the power of QTL detection; (2) Box-Cox transformation can replace some specialized transformation methods that are commonly used in QTL mapping; and (3) applying the Box-Cox transformation to data already normally distributed does not harm the result.

  16. Detector system of the first focal plane of the spectrometer SMART at RIKEN

    International Nuclear Information System (INIS)

    Okamura, H.; Izshida, S.; Sakamoto, N.; Otsu, H.; Uesaka, T.; Wakasa, T.; Satou, Y.; Sakai, H.; Ichihara, T.

    1998-01-01

    A detector system of the first focal plane of SMART, the 135 MeV/u high-resolution spectrometer at RIKEN accelerator research facility, is described. It consists of a pair of multi-wire drift chambers and a trigger scintillator hodoscope contained in a He-filled detector box. A major subject using this system is the measurement of the (d, 2 He) reaction making the most of its large angular and momentum acceptances. Without seriously sacrificing the detection efficiency, reasonably good energy and angular resolutions for 2 He, 460 keV and 9 mrad (FWHM), respectively, have been achieved after optimizing the optics property of the spectrometer. (orig.)

  17. Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

    Science.gov (United States)

    1980-01-01

    The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

  18. Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

    Science.gov (United States)

    1980-07-01

    The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

  19. Measurements of hot electrons in the Extrap T1 reversed-field pinch

    Science.gov (United States)

    Welander, A.; Bergsåker, H.

    1998-02-01

    The presence of an anisotropic energetic electron population in the edge region is a characteristic feature of reversed-field pinch (RFP) plasmas. In the Extrap T1 RFP, the anisotropic, parallel heat flux in the edge region measured by calorimetry was typically several hundred 0741-3335/40/2/011/img1. To gain more insight into the origin of the hot electron component and to achieve time resolution of the hot electron flow during the discharge, a target probe with a soft x-ray monitor was designed, calibrated and implemented. The x-ray emission from the target was measured with a surface barrier detector covered with a set of different x-ray filters to achieve energy resolution. A calibration in the range 0.5-2 keV electron energy was performed on the same target and detector assembly using a 0741-3335/40/2/011/img2 cathode electron gun. The calibration data are interpolated and extrapolated numerically. A directional asymmetry of more than a factor of 100 for the higher energy electrons is observed. The hot electrons are estimated to constitute 10% of the total electron density at the edge and their energy distribution is approximated by a half-Maxwellian with a temperature slightly higher than the central electron temperature. Scalings with plasma current, as well as correlations with local 0741-3335/40/2/011/img3 measurements and radial dependences, are presented.

  20. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [KFKI-AEKI Applied Reactor Physics, Budapest (Hungary); Pazsit, I. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Reactor Physics

    1997-12-08

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source code written in MATLAB are available at a public ftp site. The necessary information to reproduce the simulation results is also reported. (author).

  1. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Pazsit, I

    1998-04-01

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source codes written in MATLAB[reg] are available at a public ftp site. The necessary information to reproduce the simulation results is also reported.

  2. Standards and interdisciplinary treatment of boxing injuries of the head in professional boxing on the basis of an IBF World Championship Fight.

    Science.gov (United States)

    Dragu, Adrian; Unglaub, Frank; Radomirovic, Sinisa; Schnürer, Stefan; Wagner, Walter; Horch, Raymund E; Hell, Berthold

    2010-12-01

    Boxing injuries are well known in hobby boxing as well as in professional boxing. Especially in professional boxing it is of great importance to implement and follow prevention-, diagnosis- and therapy-standards in order to prevent or at least to minimize injuries of the athlete. The utmost aim would be to establish international prevention-, diagnosis- and therapy-standards for boxing injuries in professional boxing. However, this aim is on a short run unrealistic, as there are too many different professional boxing organisations with different regulations. A realistic short term aim would be to develop a national standard in order to unify the management and medical treatment of boxing injuries in professional boxing. We present the management and interdisciplinary treatment of a professional boxer with a bilateral open fracture of the mandible during a middle weight IBF World Championship Fight. On the basis of this case we want to present and discuss the possibilities of an interdisciplinary and successful medical treatment. In order to prevent or minimize boxing injuries of professional boxers, annual MRI-Scans of the head and neck have to be performed as prevention standard. Furthermore, neurocognitive tests must be performed on a regular basis. Boxing injuries in professional boxing need an interdisciplinary, unbiased and complex analysis directly at the boxing ring. The treatment of the injuries should be only performed in medical centres and thus under constant parameters. The needed qualifications must be learned in mandatory national licence courses of boxing physicians, referees and promoters.

  3. Indoor radon levels in selected hot spring hotels in Guangdong, China.

    Science.gov (United States)

    Song, Gang; Zhang, Boyou; Wang, Xinming; Gong, Jingping; Chan, Daniel; Bernett, John; Lee, S C

    2005-03-01

    Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L(-1) in the hot spring water and 17.2-190.9 Bq m(-3) in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10(-4) to 5.0x10(-3). Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation.

  4. Indoor radon levels in selected hot spring hotels in Guangdong, China

    International Nuclear Information System (INIS)

    Song Gang; Zhang Boyou; Wang Xinming; Gong Jingping; Chan, Daniel; Bernett, John; Lee, S.C.

    2005-01-01

    Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L -1 in the hot spring water and 17.2-190.9 Bq m -3 in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10 -4 to 5.0x10 -3 . Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation

  5. The BOXES Methodology Black Box Dynamic Control

    CERN Document Server

    Russell, David W

    2012-01-01

    Robust control mechanisms customarily require knowledge of the system’s describing equations which may be of the high order differential type.  In order to produce these equations, mathematical models can often be derived and correlated with measured dynamic behavior.  There are two flaws in this approach one is the level of inexactness introduced by linearizations and the other when no model is apparent.  Several years ago a new genre of control systems came to light that are much less dependent on differential models such as fuzzy logic and genetic algorithms. Both of these soft computing solutions require quite considerable a priori system knowledge to create a control scheme and sometimes complicated training program before they can be implemented in a real world dynamic system. Michie and Chambers’ BOXES methodology created a black box system that was designed to control a mechanically unstable system with very little a priori system knowledge, linearization or approximation.  All the method need...

  6. Solar 'hot spots' are still hot

    Science.gov (United States)

    Bai, Taeil

    1990-01-01

    Longitude distributions of solar flares are not random but show evidence for active zones (or hot spots) where flares are concentrated. According to a previous study, two hot spots in the northern hemisphere, which rotate with a synodic period of about 26.72 days, produced the majority of major flares, during solar cycles 20 and 21. The more prominent of these two hot spots is found to be still active during the rising part of cycle 22, producing the majority of northern hemisphere major flares. The synodic rotation period of this hot spot is 26.727 + or - 0.007 days. There is also evidence for hot spots in the southern hemisphere. Two hot spots separated by 180 deg are found to rotate with a period of 29.407 days, with one of them having persisted in the same locations during cycles 19-22 and the other, during cycles 20-22.

  7. SiliPET: An ultra-high resolution design of a small animal PET scanner based on stacks of double-sided silicon strip detector

    International Nuclear Information System (INIS)

    Di Domenico, Giovanni; Zavattini, Guido; Cesca, Nicola; Auricchio, Natalia; Andritschke, Robert; Schopper, Florian; Kanbach, Gottfried

    2007-01-01

    We investigated with Monte Carlo simulations, using the EGSNrcMP code, the capabilities of a small animal PET scanner based on four stacks of double-sided silicon strip detectors. Each stack consists of 40 silicon detectors with dimension of 60x60x1 mm 3 and 128 orthogonal strips on each side. Two coordinates of the interaction are given by the strips, whereas the third coordinate is given by the detector number in the stack. The stacks are arranged to form a box of 5x5x6 cm 3 with minor sides opened; the box represents the minimal FOV of the scanner. The performance parameters of the SiliPET scanner have been estimated giving a (positron range limited) spatial resolution of 0.52 mm FWHM, and an absolute sensitivity of 5.1% at the center of system. Preliminary results of a proof of principle measurement done with the MEGA advanced Compton imager using a ∼1 mm diameter 22 Na source, showed a focal ray tracing FWHM of 1 mm

  8. Glove boxes

    International Nuclear Information System (INIS)

    Eisert, G.A.

    1979-01-01

    An arrangement for effecting access for performing work within a glove box comprises an elongate arm-length impermeable flexible sleeve, a fitting having an aperture therethrough, adapted to be secured in sealing relation in a port, in a wall of the glove box, the fitting including an outwardly extending lip having at least one continuous groove extending around its outer periphery, one end of the sleeve extending through the aperture in fitting and being folded back against the outer periphery of the lip, a resilient fastening ring securing the sleeve in sealing engagement in the groove, clamping means securing the sleeves to the lip and a glove secured in sealing relation via a bushing to the other end of the sleeve. (author)

  9. Magnetorotational Dynamo Action in the Shearing Box

    Science.gov (United States)

    Walker, Justin; Boldyrev, Stanislav

    2017-10-01

    Magnetic dynamo action caused by the magnetorotational instability is studied in the shearing-box approximation with no imposed net magnetic flux. Consistent with recent studies, the dynamo action is found to be sensitive to the aspect ratio of the box: it is much easier to obtain in tall boxes (stretched in the direction normal to the disk plane) than in long boxes (stretched in the radial direction). Our direct numerical simulations indicate that the dynamo is possible in both cases, given a large enough magnetic Reynolds number. To explain the relatively larger effort required to obtain the dynamo action in a long box, we propose that the turbulent eddies caused by the instability most efficiently fold and mix the magnetic field lines in the radial direction. As a result, in the long box the scale of the generated strong azimuthal (stream-wise directed) magnetic field is always comparable to the scale of the turbulent eddies. In contrast, in the tall box the azimuthal magnetic flux spreads in the vertical direction over a distance exceeding the scale of the turbulent eddies. As a result, different vertical sections of the tall box are permeated by large-scale nonzero azimuthal magnetic fluxes, facilitating the instability. NSF AGS-1261659, Vilas Associates Award, NSF-Teragrid Project TG-PHY110016.

  10. Resolving hot spot microstructure using x-ray penumbral imaging (invited)

    Science.gov (United States)

    Bachmann, B.; Hilsabeck, T.; Field, J.; Masters, N.; Reed, C.; Pardini, T.; Rygg, J. R.; Alexander, N.; Benedetti, L. R.; Döppner, T.; Forsman, A.; Izumi, N.; LePape, S.; Ma, T.; MacPhee, A. G.; Nagel, S.; Patel, P.; Spears, B.; Landen, O. L.

    2016-11-01

    We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 μm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 μm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.

  11. Resolving hot spot microstructure using x-ray penumbral imaging (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Bachmann, B., E-mail: bachmann2@llnl.gov; Field, J.; Masters, N.; Pardini, T.; Rygg, J. R.; Benedetti, L. R.; Döppner, T.; Izumi, N.; LePape, S.; Ma, T.; MacPhee, A. G.; Nagel, S.; Patel, P.; Spears, B.; Landen, O. L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hilsabeck, T.; Reed, C.; Alexander, N.; Forsman, A. [General Atomics, San Diego, California 92186 (United States)

    2016-11-15

    We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 μm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 μm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.

  12. Resolving hot spot microstructure using x-ray penumbral imaging (invited).

    Science.gov (United States)

    Bachmann, B; Hilsabeck, T; Field, J; Masters, N; Reed, C; Pardini, T; Rygg, J R; Alexander, N; Benedetti, L R; Döppner, T; Forsman, A; Izumi, N; LePape, S; Ma, T; MacPhee, A G; Nagel, S; Patel, P; Spears, B; Landen, O L

    2016-11-01

    We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 μm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 μm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.

  13. Resolving hot spot microstructure using x-ray penumbral imaging (invited)

    International Nuclear Information System (INIS)

    Bachmann, B.; Field, J.; Masters, N.; Pardini, T.; Rygg, J. R.; Benedetti, L. R.; Döppner, T.; Izumi, N.; LePape, S.; Ma, T.; MacPhee, A. G.; Nagel, S.; Patel, P.; Spears, B.; Landen, O. L.; Hilsabeck, T.; Reed, C.; Alexander, N.; Forsman, A.

    2016-01-01

    We have developed and fielded x-ray penumbral imaging on the National Ignition Facility in order to enable sub-10 μm resolution imaging of stagnated plasma cores (hot spots) of spherically shock compressed spheres and shell implosion targets. By utilizing circular tungsten and tantalum apertures with diameters ranging from 20 μm to 2 mm, in combination with image plate and gated x-ray detectors as well as imaging magnifications ranging from 4 to 64, we have demonstrated high-resolution imaging of hot spot plasmas at x-ray energies above 5 keV. Here we give an overview of the experimental design criteria involved and demonstrate the most relevant influences on the reconstruction of x-ray penumbral images, as well as mitigation strategies of image degrading effects like over-exposed pixels, artifacts, and photon limited source emission. We describe experimental results showing the advantages of x-ray penumbral imaging over conventional Fraunhofer and photon limited pinhole imaging and showcase how internal hot spot microstructures can be resolved.

  14. Opportunities in white-box cryptography

    NARCIS (Netherlands)

    Michiels, W.

    White-box cryptography is the discipline of implementing a cryptographic algorithm in software such that an adversary will have difficulty extracting the cryptographic key. This approach assumes that the adversary has full access to and full control over the implementation's execution. White-box

  15. Seismic stability of a standalone glove box structure

    Energy Technology Data Exchange (ETDEWEB)

    Saraswat, A., E-mail: anupams@barc.gov.in [Bhabha Atomic Research Centre, Mumbai (India); Reddy, G.R. [Bhabha Atomic Research Centre, Mumbai (India); Ghosh, S. [Indian Institute of Technology Bombay, Mumbai (India); Ghosh, A.K.; Kumar, Arun [Bhabha Atomic Research Centre, Mumbai (India)

    2014-09-15

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  16. Seismic stability of a standalone glove box structure

    International Nuclear Information System (INIS)

    Saraswat, A.; Reddy, G.R.; Ghosh, S.; Ghosh, A.K.; Kumar, Arun

    2014-01-01

    Highlights: • Glove box is a leak tight, safety related structure used for handling radiotoxic materials. • To study the seismic performance of a freestanding glove box, extensive shake table testing has been carried out. • Glove box maintained structural integrity and leak tightness up to design basis earthquake loading. • Detailed three-dimensional finite element model of the structure is developed and analyzed by using direct time integration methods. • Simplified numerical method is proposed and successfully applied, to quickly estimate sliding displacement and determine upper bounds for it. - Abstract: In a nuclear fuel cycle facility, radiotoxic materials are being handled in freestanding leak tight enclosures called glove boxes (GBs). These glove boxes act as a primary confinement for the radiotoxic materials. Glove boxes are designed as per codal requirements for class I component. They are designed to withstand extreme level of earthquake loading with a return period of 10,000 years. To evaluate seismic performance of the glove box, there is a need to check the stability (sliding and overturning), structural integrity (stresses and strains) and leak tightness under earthquake loading. Extensive shake table experiments were conducted on a single standalone glove box. Actual laboratory conditions were simulated during testing to check the response. After extensive shake table testing, glove box structure was also analyzed using finite element (FE) software. Detailed three-dimensional model of glove box structure was developed and analyzed using nonlinear time history method. It was observed that finite element methods could be utilized to accurately predict dynamic response of glove box structure. This paper discusses the details and results of shake table testing and methodology used for modelling and analysing freestanding glove box structure under seismic loading. In addition, simplified numerical procedure, developed using energy conservation

  17. Solar hot spots are still hot

    International Nuclear Information System (INIS)

    Bai, T.

    1990-01-01

    Longitude distributions of solar flares are not random but show evidence for active zones (or hot spots) where flares are concentrated. According to a previous study, two hot spots in the northern hemisphere, which rotate with a synodic period of about 26.72 days, produced the majority of major flares, during solar cycles 20 and 21. The more prominent of these two hot spots is found to be still active during the rising part of cycle 22, producing the majority of northern hemisphere major flares. The synodic rotation period of this hot spot is 26.727 + or - 0.007 days. There is also evidence for hot spots in the southern hemisphere. Two hot spots separated by 180 deg are found to rotate with a period of 29.407 days, with one of them having persisted in the same locations during cycles 19-22 and the other, during cycles 20-22. 14 refs

  18. GLASS BOX

    National Research Council Canada - National Science Library

    Curtis, Laura

    2008-01-01

    The goals of this effort were to develop Glass Box capabilities to allow for the capturing of analyst activities and the associated data resources, track and log the results of automated processing...

  19. The lithium vapor box divertor

    International Nuclear Information System (INIS)

    Goldston, R J; Schwartz, J; Myers, R

    2016-01-01

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m −2 , implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et al as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. At the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma. (paper)

  20. Policy statement—Boxing participation by children and adolescents.

    Science.gov (United States)

    Purcell, Laura; LeBlanc, Claire M A

    2011-09-01

    Thousands of boys and girls younger than 19 years participate in boxing in North America. Although boxing provides benefits for participants, including exercise, self-discipline, and self-confidence, the sport of boxing encourages and rewards deliberate blows to the head and face. Participants in boxing are at risk of head, face, and neck injuries, including chronic and even fatal neurologic injuries. Concussions are one of the most common injuries that occur with boxing. Because of the risk of head and facial injuries, the American Academy of Pediatrics and the Canadian Paediatric Society oppose boxing as a sport for children and adolescents. These organizations recommend that physicians vigorously oppose boxing in youth and encourage patients to participate in alternative sports in which intentional head blows are not central to the sport.

  1. Spirit Boxes: Expressions of Culture.

    Science.gov (United States)

    DeMuro, Ted

    1984-01-01

    After studying the culture and art of the ancient civilizations of South America, Mesopotamia, Greece, and Egypt, secondary level art students made spirit boxes as expressions of the various cultures. How to make the boxes and how to prepare the face molds are described. (RM)

  2. HOT 2015

    DEFF Research Database (Denmark)

    Hannibal, Sara Stefansen

    2016-01-01

    HOT samler og formidler 21 literacykyndiges bud på, hvad der er hot, og hvad der bør være hot inden for literacy – og deres begrundelser for disse bud.......HOT samler og formidler 21 literacykyndiges bud på, hvad der er hot, og hvad der bør være hot inden for literacy – og deres begrundelser for disse bud....

  3. Decontamination of TRU glove boxes

    International Nuclear Information System (INIS)

    Crawford, J.H.

    1978-03-01

    Two glove boxes that had been used for work with transuranic nuclides (TRU) for about 12 years were decontaminated in a test program to collect data for developing a decontamination facility for large equipment highly contaminated with alpha emitters. A simple chemical technique consisting of a cycle of water flushes and alkaline permanganate and oxalic acid washes was used for both boxes. The test showed that glove boxes and similar equipment that are grossly contaminated with transuranic nuclides can be decontaminated to the current DIE nonretrievable disposal guide of <10 nCi TRU/g with a moderate amount of decontamination solution and manpower. Decontamination of the first box from an estimated 1.3 Ci to about 5 mCi (6 nCi/g) required 1.3 gallons of decontamination solution and 0.03 man-hour of work for each square foot of surface area. The second box was decontaminated from an estimated 3.4 Ci to about 2.8 mCi (4.2 nCi/g) using 0.9 gallon of decontamination solution and 0.02 man-hour for each square foot of surface area. Further reductions in contamination were achieved by repetitive decontamination cycles, but the effectiveness of the technique decreased sharply after the initial cycle

  4. Grey-Box Modelling of Pharmacokinetic /Pharmacodynamic Systems

    DEFF Research Database (Denmark)

    Tornøe, Christoffer Wenzel; Jacobsen, Judith L.; Pedersen, Oluf

    2004-01-01

    Grey-box pharmacokinetic/pharmacodynamic (PK/PD) modelling is presented as a promising way of modelling PK/PD systems. The concept behind grey-box modelling is based on combining physiological knowledge along with information from data in the estimation of model parameters. Grey-box modelling...

  5. Packing a cake into a box

    KAUST Repository

    Skopenkov, Mikhail

    2011-01-01

    Given a triangular cake and a box in the shape of its mirror image, how can the cake be cut into a minimal number of pieces so that it can be put into the box? The cake has icing, so we are not allowed to put it into the box upside down. V. G. Boltyansky asked this question in 1977 and showed that three pieces always suffice. In this paper we provide examples of cakes that cannot be cut into two pieces to be put into the box. This shows that three is the answer to Boltyansky's question. We also give examples of cakes which can be cut into two pieces. © THE MATHEMATICAL ASSOCIATION OF AMERICA.

  6. Packing a cake into a box

    KAUST Repository

    Skopenkov, Mikhail

    2011-05-01

    Given a triangular cake and a box in the shape of its mirror image, how can the cake be cut into a minimal number of pieces so that it can be put into the box? The cake has icing, so we are not allowed to put it into the box upside down. V. G. Boltyansky asked this question in 1977 and showed that three pieces always suffice. In this paper we provide examples of cakes that cannot be cut into two pieces to be put into the box. This shows that three is the answer to Boltyansky\\'s question. We also give examples of cakes which can be cut into two pieces. © THE MATHEMATICAL ASSOCIATION OF AMERICA.

  7. Cleanout and decontamination of radiochemical hot cells

    International Nuclear Information System (INIS)

    Surma, J.E.; Holton, L.K. Jr.; Katayama, Y.B.; Gose, J.E.; Haun, F.E.; Dierks, R.D.

    1990-01-01

    The Pacific Northwest Laboratory is developing and employing advanced remote and contact technologies in cleaning out and decontaminating six radiochemical hot cells at Hanford under the Department of Energy's Surplus Facilities Management Program. The program is using a series of remote and contact decontamination techniques to reduce costs and to significantly lower radiation doses to workers. Refurbishment of the cover blocks above the air lock trench reduced radiation exposure in the air lock and cleanout and decontamination of an analytical cell achieved a reduction in radioactive contamination. Nuclear Regulatory Commission-approved Type B burial boxes are also being used to reduce waste disposal costs and radiation doses. PNL is currently decommissioning its pilot-scale radioactive liquid-fed ceramic melter. Special tools have been developed and are being used to accomplish the world's first such effort. 4 refs., 5 figs

  8. Ion-wake Field inside a Glass Box

    OpenAIRE

    Chen, Mudi; Dropmann, Michael; Zhang, Bo; Matthews, Lorin S.; Hyde, Truell W.

    2016-01-01

    The confinement provided by a glass box is proving ideal for the formation of vertically aligned structures and a convenient method for controlling the number of dust particles comprising these dust structures, as well as their size and shape. In this paper, the electronic confinement of the glass box is mapped and the particle interactions between the particle pairs inside the glass box are measured. The ion-wake field is shown to exist within the glass box and its vertical and horizontal ex...

  9. Water-cooled target-box design at LAMPF

    International Nuclear Information System (INIS)

    Grisham, D.; Lambert, J.

    1983-01-01

    The target boxes in the main experimental beam line (Line A) at the Clinton P. Anderson Meson Physics Facility (LAMPF) have operated since 1976. A program of replacing the boxes is underway. This paper will present past history, design considerations, calculational results and the final box design

  10. Optimization of high pressure machine decocting process for Dachengqi Tang using HPLC fingerprints combined with the Box–Behnken experimental design

    Directory of Open Access Journals (Sweden)

    Rui-Fang Xie

    2015-04-01

    Full Text Available Using Dachengqi Tang (DCQT as a model, high performance liquid chromatography (HPLC fingerprints were applied to optimize machine extracting process with the Box–Behnken experimental design. HPLC fingerprints were carried out to investigate the chemical ingredients of DCQT; synthetic weighing method based on analytic hierarchy process (AHP and criteria importance through intercriteria correlation (CRITIC was performed to calculate synthetic scores of fingerprints; using the mark ingredients contents and synthetic scores as indicators, the Box–Behnken design was carried out to optimize the process parameters of machine decocting process under high pressure for DCQT. Results of optimal process showed that the herb materials were soaked for 45 min and extracted with 9 folds volume of water in the decocting machine under the temperature of 140 °C till the pressure arrived at 0.25 MPa; then hot decoction was excreted to soak Dahuang and Mangxiao for 5 min. Finally, obtained solutions were mixed, filtrated and packed. It concluded that HPLC fingerprints combined with the Box–Behnken experimental design could be used to optimize extracting process of traditional Chinese medicine (TCM. Keywords: Dachengqi Tang, HPLC fingerprints, Box–Behnken design, Synthetic weighing method

  11. Construction of dry-boxes for plutonium metallurgy

    International Nuclear Information System (INIS)

    Grison, E.; Pascard, R.

    1958-01-01

    The dry-boxes used at Chatillon are of two main types: a) boxes with a metal frame work of welded angle-pieces, panels of plexiglass, bakelite, duralumin, etc... They include a standard panel which enables them to be connected up to the contaminated repairs workshop; b) boxes made entirely of welded plastic. The working face only is of plexiglas held by screw clamps to a pure rubber joint. These boxes, which cannot be connected to the contaminated workshop, are generally reserved for small pieces of chemical apparatus. None has yet been used for working under argon, although their airtightness is excellent. After an interval of several hours, in fact, no decrease in the pressure inside the box can be detected. Several means can be adopted to ensure that the joints between panels and mountings are absolutely air-tight. Up to the present we are using three types of box with metal framework at the same time, without being able to make a definitive choice. (author) [fr

  12. 49 CFR 178.515 - Standards for reconstituted wood boxes.

    Science.gov (United States)

    2010-10-01

    ... wood boxes. (a) The identification code for a reconstituted wood box is 4F. (b) Construction requirements for reconstituted wood boxes are as follows: (1) The walls of boxes must be made of water... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for reconstituted wood boxes. 178.515...

  13. Ocular complications of boxing

    Science.gov (United States)

    Bianco, M; Vaiano, A; Colella, F; Coccimiglio, F; Moscetti, M; Palmieri, V; Focosi, F; Zeppilli, P; Vinger, P

    2005-01-01

    Objectives: To investigate the prevalence of ocular injuries in a large population of boxers over a period of 16 years, in particular, the most severe lesions that may be vision threatening. Methods: Clinical records of the medical archive of the Italian Boxing Federation were analysed. A total of 1032 boxers were examined from February 1982 to October 1998. A complete ophthalmological history was available for 956, who formed the study population (a total of 10 697 examinations). The following data were collected: age when started boxing; duration of competitive boxing career (from the date of the first bout); weight category; a thorough ocular history. The following investigations were carried out: measurement of visual acuity and visual fields, anterior segment inspection, applanation tonometry, gonioscopy, and examination of ocular fundus. Eighty age matched healthy subjects, who had never boxed, formed the control group. Results: Of the 956 boxers examined, 428 were amateur (44.8%) and 528 professional (55.2%). The median age at first examination was 23.1 (4.3) years (range 15–36). The prevalence of conjunctival, corneal, lenticular, vitreal, ocular papilla, and retinal alterations in the study population was 40.9% compared with 3.1% in the control group (p⩽0.0001). The prevalence of serious ocular findings (angle, lens, macula, and peripheral retina alterations) was 5.6% in boxers and 3.1% in controls (NS). Conclusions: Boxing does not result in a higher prevalence of severe ocular lesions than in the general population. However, the prevalence of milder lesions (in particular with regard to the conjunctiva and cornea) is noteworthy, justifying the need for adequate ophthalmological surveillance. PMID:15665199

  14. HotRegion: a database of predicted hot spot clusters.

    Science.gov (United States)

    Cukuroglu, Engin; Gursoy, Attila; Keskin, Ozlem

    2012-01-01

    Hot spots are energetically important residues at protein interfaces and they are not randomly distributed across the interface but rather clustered. These clustered hot spots form hot regions. Hot regions are important for the stability of protein complexes, as well as providing specificity to binding sites. We propose a database called HotRegion, which provides the hot region information of the interfaces by using predicted hot spot residues, and structural properties of these interface residues such as pair potentials of interface residues, accessible surface area (ASA) and relative ASA values of interface residues of both monomer and complex forms of proteins. Also, the 3D visualization of the interface and interactions among hot spot residues are provided. HotRegion is accessible at http://prism.ccbb.ku.edu.tr/hotregion.

  15. Application of MOSFET radiation detector for patient dosimetry

    International Nuclear Information System (INIS)

    Soubra, M.; Cygler, J.; Szanto, J.

    1996-01-01

    Purpose: A new direct reading Metal Oxide-Silicon Field Effect Transistor (MOSFET) based radiation detector system has been investigated in a variety of clinical radiotherapy procedures. The aim of this study is to report on the clinical applicability of such a device, its ease of use and on its dosimetric properties that include precision angular and energy dependence. Comparisons of patient dose measurements obtained by the MOSFET based system and the commonly used thermoluminescence dosimeters (TLD) and diodes are discussed. Material and Methods: A commercially available MOSFET dosimetry system that employs dual MOSFET dual bias arrangements has been used in this study. The detector is bonded with the epoxy to the end of a long (1.5 m) flexible cable whose other end is connected to a bias supply box operated by a battery. The bias box can accommodate up to 5 MOSFETs and after radiation exposure the dose can be determined by connecting the detectors to a pre calibrated reader. For the clinical evaluation 5 MOSFETs were used on patients undergoing total body irradiation (TBI) and high dose rate brachytherapy (HDR). The MOSFET detectors were taped to patient surface adjacent to the routinely used TLDs and/or diodes. To examine energy dependence the MOSFET sensitivity (mV/Gy) was determined in relation to a calibrated dose from 6 and 18 MV photon beams. The directional dependence was investigated by placing a MOSFET during irradiation in a special polystyrene insert that can be manually rotated to the required angle. Precision (reproducibility) measurements were made by exposing MOSFETs to multiple fractions of dose in the range of 3 x 10 -2 to 2 Gy. Results: In 3 of TBI trials the diodes measured average dose was within 1.0% of the prescribed dose compared to 3.7% for TLDs and 1.8% for MOSFETs. The MOSFETs average sensitivity for 6 MV was within 2% of the 18 MV photon beam. The reproducibility of MOSFET response was better than 3 % provided the dose per fraction is

  16. 49 CFR 178.517 - Standards for plastic boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for plastic boxes. 178.517 Section 178... PACKAGINGS Non-bulk Performance-Oriented Packaging Standards § 178.517 Standards for plastic boxes. (a) The following are identification codes for plastic boxes: (1) 4H1 for an expanded plastic box; and (2) 4H2 for a...

  17. Nonneurologic emergencies in boxing.

    Science.gov (United States)

    Coletta, Domenic F

    2009-10-01

    Professional boxing has done an admirable job in promoting safety standards in its particular sport. However, injuries occur during the normal course of competition and, unfortunately, an occasional life-threatening emergency may arise. Although most common medical emergencies in boxing are injuries from closed head trauma, in this article those infrequent but potentially catastrophic nonneurologic conditions are reviewed along with some less serious emergencies that the physician must be prepared to address.

  18. Indoor radon levels in selected hot spring hotels in Guangdong, China

    Energy Technology Data Exchange (ETDEWEB)

    Song Gang [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China); Zhang Boyou [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China); Wang Xinming [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China)]. E-mail: wangxm@gig.ac.cn; Gong Jingping [Guangzhou Institute of Geochemistry, Chinese Academy of Science, Guangzhou 510640 (China); Chan, Daniel [Department of Building Services Engineering, Hong Kong Polytechnic University, Hong Kong (China); Bernett, John [Department of Building Services Engineering, Hong Kong Polytechnic University, Hong Kong (China); Lee, S.C. [Department of Civil and Structural Engineering, Hong Kong Polytechnic University, Hong Kong (China)

    2005-03-01

    Guangdong is one of the provinces that have most hot springs in China, and many hotels have been set up near hot springs, with spring water introduced into the bath inside each hotel room for hot spring bathing to attract tourists. In the present study, we measured radon in indoor and outdoor air, as well as in hot spring waters, in four hot spring hotels in Guangdong by using NR-667A (III) continuous radon detector. Radon concentrations ranged 53.4-292.5 Bq L{sup -1} in the hot spring water and 17.2-190.9 Bq m{sup -3} in outdoor air. Soil gas intrusion, indoor hot spring water use and inefficient ventilation all contributed to the elevated indoor radon levels in the hotel rooms. From the variation of radon levels in closed unoccupied hotel rooms, soil gas intrusion was found to be a very important source of indoor radon in hotel rooms with floors in contact with soils. When there was spring water bathing in the bathes, average radon levels were 10.9-813% higher in the hotel rooms and 13.8-489% higher in bathes compared to their corresponding average levels when there was no spring water use. Spring water use in the hotel rooms had radon transfer coefficients from 1.6x10{sup -4} to 5.0x10{sup -3}. Radon in some hotel rooms maintained in concentrations much higher than guideline levels might thus have potential health risks to the hotel workers, and technical and management measures should be taken to lower their exposure of radon through inhalation.

  19. Glove boxes. Dimensions and requirements. Draft

    International Nuclear Information System (INIS)

    1985-07-01

    The standard is to be applied to work done in glove-boxes, whereby either the personnel need to be protected from the damaging effects of the materials being handled, or the materials from the effects of the environment. It is to be applied to glove-boxes in which substances are handled which emit ionising radiation (radioactive substances). This norm is not restricted to glove-boxes in which processes are carried out on a technique scale. In accordance with this norm, only those pressures and temperatures are allowed to be present in the glove-boxes, that do not offer significantly from the work areas. Alongside the stipulations of this standard regard is also always to be taken of the regulations in the radiation protection ordinance. (orig./HP) [de

  20. Introduction to the Box Particle Filtering

    OpenAIRE

    Gning, Amadou; Ristic, B; Mihaylova, Lyudmila; Abdallah, F.

    2013-01-01

    This paper presents a novel method for solving nonlinear filtering problems. This approach is particularly appealing in practical situations involving imprecise stochastic measurements, thus resulting in very broad posterior densities. It relies on the concept of a box particle, which occupies a small and controllable rectangular region having a non-zero volume in the state space. Key advantages of the box particle filter (Box-PF) against the standard particle filter (PF) are in its reduced c...

  1. Amateur boxing: physical and physiological attributes.

    Science.gov (United States)

    Chaabène, Helmi; Tabben, Montassar; Mkaouer, Bessem; Franchini, Emerson; Negra, Yassine; Hammami, Mehrez; Amara, Samiha; Chaabène, Raja Bouguezzi; Hachana, Younés

    2015-03-01

    Boxing is one of the oldest combat sports. The aim of the current review is to critically analyze the amateur boxer's physical and physiological characteristics and to provide practical recommendations for training as well as new areas of scientific research. High-level male and female boxers show a propensity for low body fat levels. Although studies on boxer somatotypes are limited, the available information shows that elite-level male boxers are characterized by a higher proportion of mesomorphy with a well-developed muscle mass and a low body fat level. To help support the overall metabolic demands of a boxing match and to accelerate the recovery process between rounds, athletes of both sexes require a high level of cardiorespiratory fitness. International boxers show a high peak and mean anaerobic power output. Muscle strength in both the upper and lower limbs is paramount for a fighter's victory and is one of the keys to success in boxing. As boxing punches are brief actions and very dynamic, high-level boxing performance requires well-developed muscle power in both the upper and lower limbs. Albeit limited, the available studies reveal that isometric strength is linked to high-level boxing performance. Future investigations into the physical and physiological attributes of boxers are required to enrich the current data set and to help create a suitable training program.

  2. Influence of dimension box differences and time differences during operations of red box for motorcycles at signalized intersection

    Science.gov (United States)

    Mulyadi, Agah Muhammad

    2017-11-01

    Performance of signalized intersection has declined due to a large number of motorcycles. The number of motorcycles reached 98.2 million units and the composition of motorcycles has reached around 81.7% of the total composition of vehicles in Indonesia (AISI, 2017). To solve that problem, the red box for motorcycles are provided at the signalized intersection. Red box for the motorcycle at signalized intersections was developed from the concept of Advance Stop Line (ASL) for bicycles. The Red Box was developed to split the queue between motorcycles and other vehicles when waiting at red light. This paper aims to evaluate the influence of the red box dimension and red time operation differences. The survey was conducted as many as 30 cycles of traffic signals per day. The data were analyzed using software IBM SPSS Statistics 20 by using Analysis of Variance (ANOVA) to obtain p-value (significant). The analysis shows that there are insignificant influences between the occupancy rates to the dimension of Red Box. Furthermore, that there is a significant difference that shows the dependency of only motorcycles in the Red Box Area towards red time operation.

  3. Characterization of Multianode Photomultiplier Tubes for a Cherenkov Detector

    Science.gov (United States)

    Benninghoff, Morgen; Turisini, Matteo; Kim, Andrey; Benmokhtar, Fatiha; Kubarovsky, Valery; Duquesne University Collaboration; Jefferson Lab Collaboration

    2017-09-01

    In the Fall of 2017, Jefferson Lab's CLAS12 (CEBAF Large Acceptance Spectrometer) detector is expecting the addition of a RICH (ring imaging Cherenkov) detector which will allow enhanced particle identification in the momentum range of 3 to 8 GeV/c. RICH detectors measure the velocity of charged particles through the detection of produced Cherenkov radiation and the reconstruction of the angle of emission. The emitted Cherenkov photons are detected by a triangular-shaped grid of 391 multianode photomultiplier tubes (MAPMTs) made by Hamamatsu. The custom readout electronics consist of MAROC (multianode read out chip) boards controlled by FPGA (Field Programmable Gate Array) boards, and adapters used to connect the MAROC boards and MAPMTs. The focus of this project is the characterization of the MAPMTs with the new front end electronics. To perform these tests, a black box setup with a picosecond diode laser was constructed with low and high voltage supplies. A highly automated procedure was developed to acquire data at different combinations of high voltage values, light intensities and readout electronics settings. Future work involves using the collected data in calibration procedures and analyzing that data to resolve the best location for each MAPMT. SULI, NSF.

  4. Hot Laboratories and Remote Handling

    International Nuclear Information System (INIS)

    2007-01-01

    The Opening talk of the workshop 'Hot Laboratories and Remote Handling' was given by Marin Ciocanescu with the communication 'Overview of R and D Program in Romanian Institute for Nuclear Research'. The works of the meeting were structured into three sections addressing the following items: Session 1. Hot cell facilities: Infrastructure, Refurbishment, Decommissioning; Session 2. Waste, transport, safety and remote handling issues; Session 3. Post-Irradiation examination techniques. In the frame of Section 1 the communication 'Overview of hot cell facilities in South Africa' by Wouter Klopper, Willie van Greunen et al, was presented. In the framework of the second session there were given the following four communications: 'The irradiated elements cell at PHENIX' by Laurent Breton et al., 'Development of remote equipment for DUPIC fuel fabrication at KAERI', by Jung Won Lee et al., 'Aspects of working with manipulators and small samples in an αβγ-box, by Robert Zubler et al., and 'The GIOCONDA experience of the Joint Research Centre Ispra: analysis of the experimental assemblies finalized to their safe recovery and dismantling', by Roberto Covini. Finally, in the framework of the third section the following five communications were presented: 'PIE of a CANDU fuel element irradiated for a load following test in the INR TRIGA reactor' by Marcel Parvan et al., 'Adaptation of the pole figure measurement to the irradiated items from zirconium alloys' by Yury Goncharenko et al., 'Fuel rod profilometry with a laser scan micrometer' by Daniel Kuster et al., 'Raman spectroscopy, a new facility at LECI laboratory to investigate neutron damage in irradiated materials' by Lionel Gosmain et al., and 'Analysis of complex nuclear materials with the PSI shielded analytical instruments' by Didier Gavillet. In addition, eleven more presentations were given as posters. Their titles were: 'Presentation of CETAMA activities (CEA analytic group)' by Alain Hanssens et al. 'Analysis of

  5. 49 CFR 178.512 - Standards for steel or aluminum boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for steel or aluminum boxes. 178.512... aluminum boxes. (a) The following are identification codes for steel or aluminum boxes: (1) 4A for a steel box; and (2) 4B for an aluminum box. (b) Construction requirements for steel or aluminum boxes are as...

  6. Relativistic particle in a box

    OpenAIRE

    Alberto, P.; Fiolhais, Carlos; Gil, Victor

    1996-01-01

    The problem of a relativistic spin 1/2 particle confined to a one-dimensional box is solved in a way that resembles closely the solution of the well known quantum-mechanical textbook problem of a non-relativistic particle in a box. The energy levels and probability density are computed and compared with the non-relativistic case

  7. What Makes a Better Box?

    Science.gov (United States)

    Moyer, Richard; Everett, Susan

    2010-01-01

    Every morning, many Americans start their day with a bowl of cereal. Some spend time while they eat breakfast reading the back of the cereal box, but few consider its size, shape, and construction, or realize that it was designed by an engineer. This article describes a lesson in which students design, build, and critique cereal boxes. The lesson…

  8. Infectious disease and boxing.

    Science.gov (United States)

    King, Osric S

    2009-10-01

    There are no unique boxing diseases but certain factors contributing to the spread of illnesses apply strongly to the boxer, coach, and the training facility. This article examines the nature of the sport of boxing and its surrounding environment, and the likelihood of spread of infection through airborne, contact, or blood-borne routes of transmission. Evidence from other sports such as running, wrestling, and martial arts is included to help elucidate the pathophysiologic elements that could be identified in boxers.

  9. The applicability of a multitask boxing program using the BoxMaster ® for Parkinson’s disease

    OpenAIRE

    Domingos, Josefa; Loureiro, Rita; Godinho, Catarina; Dean, John; Ferreira, Joaquim J.

    2016-01-01

    Poster presented at the 4th World Parkinson Congress. Portland, Oregon, 20-23 September 2016 "Objective: To test the applicability of a multitasking boxing program using the BoxMaster® in individuals with Parkinson’s disease that combines motor, cognitive and vocal exercises." N/A

  10. Cosmetic Foot Surgery: Fashion's Pandora's Box

    Science.gov (United States)

    ... Fashion’s Pandora’s Box? A A A | Print | Share Cosmetic Foot Surgery: Fashion’s Pandora’s Box? Foot and ankle ... extreme and imprudent as it may sound, the cosmetic surgery craze is not just for faces anymore— ...

  11. Fuel assembly and fuel channel box

    International Nuclear Information System (INIS)

    Sakuma, Toraki; Hirakawa, Hiromasa; Ishizaki, Hideaki; Nakajima, Junjiro; Aizawa, Yasuhiro.

    1992-01-01

    A fuel channel box has a square cylindrical shape and, in the transversal cross sectional shape, the wall thickness of a corner portion is greater than that of a central portion of the side wall except for an upper portion thereof. The upper portion of the channel box includes a region to be in contact with an upper lattice plate and a region to attach a channel spacer. Then, the wall thickness of these regions is uniform in the transversal cross section and they have the same wall thickness with that of the corner portion which has the increased wall thickness. With such a constitution, the upper portion of the channel box receives a counter force applied from the upper lattice plate upon occurrence of earthquakes and moderate it to reduce local stresses and deformation. Further, a similar region with increased wall thickness is disposed also to the lower portion of the channel box, thereby enabling to suppress the amount of coolants leaked from a portion between the lower portion and a lower tie plate, and improve the mechanical integrity of the channel box. (I.N.)

  12. Getting started with Citrix VDI-in-a-Box

    CERN Document Server

    Brown, Stuart Arthur

    2013-01-01

    A practical and fast-paced guide that gives you all the information you need to simplify and streamline virtual desktops so you get a production-quality solution while instantly lowering your costs and improving security.Getting Started with Citrix VDI-in-a-Box is great for IT professionals who are new to VDI-in-a-Box and who are looking for a good grounding in the product. You may be planning to research VDI-in-a-Box in more detail, or you may be tasked with researching how VDI-in-a-Box could improve the productivity of your organization. No prior knowledge of VDI-in-a-Box is required, just a

  13. Spacer for supporting fuel element boxes

    International Nuclear Information System (INIS)

    Wild, E.

    1979-01-01

    A spacer plate unit arranged externally on each side and at a predetermined level of a polygonal fuel element box for mutually supporting, with respect to one another, a plurality of the fuel element boxes forming a fuel element bundle, is formed of a first and a second spacer plate part each having the same length and the same width and being constituted of unlike first and second materials, respectively. The first and second spacer plate parts of the several spacer plate units situated at the predetermined level are arranged in an alternating continuous series when viewed in the peripheral direction of the fuel element box, so that any two spacer plate units belonging to face-to-face oriented sides of two adjoining fuel element boxes in the fuel element bundle define interfaces of unlike materials

  14. Sport medicine and the ethics of boxing

    Science.gov (United States)

    Leclerc, S.; Herrera, C. D.

    1999-01-01

    In the light of medical evidence of the health risks associated with boxing, a watchful agnostic position among sport physicians is no longer justifiable. The normal activity in a boxing match places the athletes at risk of head injury, some of which may be difficult to detect and impossible to repair. This suggests that sport physicians and others expert in the prevention and diagnosis of such injuries should take a public stand against boxing, as other medical associations have. Although there is a need for continuing research into the health risks, doctors can in the interim take steps to increase public awareness of these risks. Sport physicians in particular can make a strong public statement by also ending their professional involvement with boxing. This need not be interpreted as paternalism; doctors are qualified neither to make laws nor to restrict private behaviour. Sport physicians are, however, well equipped to advise those who do make laws and those who choose to engage in boxing. In the end, because this stance against boxing will probably reduce the number of brain injuries in certain athletes, autonomy will be preserved, rather than restricted. 


 PMID:10597855

  15. Decay of Hot Nuclei at Low Spins Produced by Antiproton-Annihilation in Heavy Nuclei

    CERN Multimedia

    2002-01-01

    % PS208 \\\\ \\\\ The objective of the experiment is to study (i) the thermal excitation energy distribution of antiproton-induced reactions in heavy nuclei and (ii) the decay properties of hot nuclei at low spins via evaporation, multifragmentation and fission as a function of excitation energy. The experimental set-up consists of 4-$\\pi$ detectors: the Berlin Neutron Ball~(BNB) which is a spherical shell of gadolinium-loaded scintillator liquid with an inner and outer diameter of 40 and 160~cm, respectively. This detector counts the number of evaporated neutrons in each reaction. Inside BNB there is a 4-$\\pi$ silicon ball~(BSIB) with a diameter of 20~cm consisting of 162 detectors which measure energy and multiplicity of all emitted charged nuclear particles. The particles are identified via time of flight, energy and pulse shape correlations.

  16. A novel design of a personal nuclear track detector for ambient Rn

    International Nuclear Information System (INIS)

    Margaliot, M.; Even, O.; Herman, R.

    1997-01-01

    In some occupations, workers spend a part of their time underground, in closed and unventilated spaces, while most of their time is spent in the open air. The case in hand is a group of the 'Bezek' telephone technicians, whose work includes spending a few hours daily in small, coarsely finished and unventilated tunnels in which telephone branching boxes are located. The rest of their time they work outdoors, and a small part of it is spent in offices. The Rn levels in a few telephone branching tunnels were measured and were found to be rather high (levels of 3000 - 5000 Bq/m 3 are common). The average exposure of the workers is however much lower, due to short time spent in the tunnels, versus the longer time spent outdoors, and the low Rn level there. To obtain a well founded estimation of their actual commutative Rn exposure, a new integrative Rn detector was designed, which is attached to the workers clothing during the whole working day, and serves as a personal Rn detector, rather than as the a conventional area monitor. The detector element itself consists of a Nuclear Track Detector made of dosimetry grade CR-39. The function of the detector is how ever dependent mainly on the geometrical design of the housing of the detector. The properties of these detectors are, however, highly dependent on the design of the detectors housing.The design itself, it's theoretical efficiency, it's actual calibration process and it's calibration factor are presented. Mechanical reliability has been established in some 3 years of operation both as a fixed area monitor and as a personal portable detector. (authors)

  17. North American box turtles: A natural history

    Science.gov (United States)

    Dodd, C. Kenneth

    2002-01-01

    Once a familiar backyard visitor in many parts of the United States and Mexico, the box turtle is losing the battle against extinction. In North American Box Turtles, C. Kenneth Dodd, Jr., has written the first book-length natural history of the twelve species and subspecies of this endangered animal. This volume includes comprehensive information on the species’ evolution, behavior, courtship and reproduction, habitat use, diet, population structure, systematics, and disease. Special features include color photos of all species, subspecies, and their habitats; a simple identification guide to both living and fossil species; and a summary of information on fossil Terrapene and Native uses of box turtles. End-of-chapter sections highlight future research directions, including the need for long-term monitoring and observation of box turtles within their natural habitat and conservation applications. A glossary and a bibliography of literature on box turtles accompany the text.

  18. A new set of ESTs from chickpea (Cicer arietinum L. embryo reveals two novel F-box genes, CarF-box_PP2 and CarF-box_LysM, with potential roles in seed development.

    Directory of Open Access Journals (Sweden)

    Shefali Gupta

    Full Text Available Considering the economic importance of chickpea (C. arietinum L. seeds, it is important to understand the mechanisms underlying seed development for which a cDNA library was constructed from 6 day old chickpea embryos. A total of 8,186 ESTs were obtained from which 4,048 high quality ESTs were assembled into 1,480 unigenes that majorly encoded genes involved in various metabolic and regulatory pathways. Of these, 95 ESTs were found to be involved in ubiquitination related protein degradation pathways and 12 ESTs coded specifically for putative F-box proteins. Differential transcript accumulation of these putative F-box genes was observed in chickpea tissues as evidenced by quantitative real-time PCR. Further, to explore the role of F-box proteins in chickpea seed development, two F-box genes were selected for molecular characterization. These were named as CarF-box_PP2 and CarF-box_LysM depending on their C-terminal domains, PP2 and LysM, respectively. Their highly conserved structures led us to predict their target substrates. Subcellular localization experiment revealed that CarF-box_PP2 was localized in the cytoplasm and CarF-box_LysM was localized in the nucleus. We demonstrated their physical interactions with SKP1 protein, which validated that they function as F-box proteins in the formation of SCF complexes. Sequence analysis of their promoter regions revealed certain seed specific cis-acting elements that may be regulating their preferential transcript accumulation in the seed. Overall, the study helped in expanding the EST database of chickpea, which was further used to identify two novel F-box genes having a potential role in seed development.

  19. A new set of ESTs from chickpea (Cicer arietinum L.) embryo reveals two novel F-box genes, CarF-box_PP2 and CarF-box_LysM, with potential roles in seed development.

    Science.gov (United States)

    Gupta, Shefali; Garg, Vanika; Bhatia, Sabhyata

    2015-01-01

    Considering the economic importance of chickpea (C. arietinum L.) seeds, it is important to understand the mechanisms underlying seed development for which a cDNA library was constructed from 6 day old chickpea embryos. A total of 8,186 ESTs were obtained from which 4,048 high quality ESTs were assembled into 1,480 unigenes that majorly encoded genes involved in various metabolic and regulatory pathways. Of these, 95 ESTs were found to be involved in ubiquitination related protein degradation pathways and 12 ESTs coded specifically for putative F-box proteins. Differential transcript accumulation of these putative F-box genes was observed in chickpea tissues as evidenced by quantitative real-time PCR. Further, to explore the role of F-box proteins in chickpea seed development, two F-box genes were selected for molecular characterization. These were named as CarF-box_PP2 and CarF-box_LysM depending on their C-terminal domains, PP2 and LysM, respectively. Their highly conserved structures led us to predict their target substrates. Subcellular localization experiment revealed that CarF-box_PP2 was localized in the cytoplasm and CarF-box_LysM was localized in the nucleus. We demonstrated their physical interactions with SKP1 protein, which validated that they function as F-box proteins in the formation of SCF complexes. Sequence analysis of their promoter regions revealed certain seed specific cis-acting elements that may be regulating their preferential transcript accumulation in the seed. Overall, the study helped in expanding the EST database of chickpea, which was further used to identify two novel F-box genes having a potential role in seed development.

  20. Box-Particle Cardinality Balanced Multi-Target Multi-Bernoulli Filter

    OpenAIRE

    L. Song; X. Zhao

    2014-01-01

    As a generalized particle filtering, the box-particle filter (Box-PF) has a potential to process the measurements affected by bounded error of unknown distributions and biases. Inspired by the Box-PF, a novel implementation for multi-target tracking, called box-particle cardinality balanced multi-target multi-Bernoulli (Box-CBMeMBer) filter is presented in this paper. More important, to eliminate the negative effect of clutters in the estimation of the numbers of targets, an improved generali...

  1. 49 CFR 230.101 - Steam locomotive driving journal boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Steam locomotive driving journal boxes. 230.101... Locomotives and Tenders Running Gear § 230.101 Steam locomotive driving journal boxes. (a) Driving journal boxes. Driving journal boxes shall be maintained in a safe and suitable condition for service. Not more...

  2. Decontamination and size reduction of plutonium contaminated process exhaust ductwork and glove boxes

    International Nuclear Information System (INIS)

    LaFrate, P.; Elliott, J.; Valasquez, M.

    1996-01-01

    The Los Alamos National Laboratory (LANL) Decommissioning Program has decontaminated and demolished two filter plenum buildings at Technical Area 21 (TA-21). During the project a former hot cell was retrofitted to perform decontamination and size reduction of highly Pu contaminated process exhaust (1,100 ft) and gloveboxes. Pu-238/239 concentrations were as high a 1 Ci per linear foot and averaged approximately 1 mCi/ft. The Project decontamination objective was to reduce the plutonium contamination on surfaces below transuranic levels. If possible, metal surfaces were decontaminated further to meet Science and Ecology Group (SEG) waste classification guidelines to enable the metal to be recycled at their facility in oak Ridge, Tennessee. Project surface contamination acceptance criteria for low-level radioactive waste (LLRW), transuranic waste, and SEG waste acceptance criteria will be presented. Ninety percent of all radioactive waste for the project was characterized as LLRW. Twenty percent of this material was shipped to SEG. Process exhaust and glove boxes were brought to the project decontamination area, an old hot cell in Building 4 North. This paper focuses on process exhaust and glovebox decontamination methodology, size reduction techniques, waste characterization, airborne contamination monitoring, engineering controls, worker protection, lessons learned, and waste minimization. Decontamination objectives are discussed in detail

  3. Positional glow curve simulation for thermoluminescent detector (TLD) system design

    International Nuclear Information System (INIS)

    Branch, C.J.; Kearfott, K.J.

    1999-01-01

    Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design

  4. Grey Box Modelling of Hydrological Systems

    DEFF Research Database (Denmark)

    Thordarson, Fannar Ørn

    of two papers where the stochastic differential equation based model is used for sewer runoff from a drainage system. A simple model is used to describe a complex rainfall-runoff process in a catchment, but the stochastic part of the system is formulated to include the increasing uncertainty when...... rainwater flows through the system, as well as describe the lower limit of the uncertainty when the flow approaches zero. The first paper demonstrates in detail the grey box model and all related transformations required to obtain a feasible model for the sewer runoff. In the last paper this model is used......The main topic of the thesis is grey box modelling of hydrologic systems, as well as formulation and assessment of their embedded uncertainties. Grey box model is a combination of a white box model, a physically-based model that is traditionally formulated using deterministic ordinary differential...

  5. Black-Box Search by Unbiased Variation

    DEFF Research Database (Denmark)

    Lehre, Per Kristian; Witt, Carsten

    2012-01-01

    The complexity theory for black-box algorithms, introduced by Droste, Jansen, and Wegener (Theory Comput. Syst. 39:525–544, 2006), describes common limits on the efficiency of a broad class of randomised search heuristics. There is an obvious trade-off between the generality of the black-box model...... and the strength of the bounds that can be proven in such a model. In particular, the original black-box model provides for well-known benchmark problems relatively small lower bounds, which seem unrealistic in certain cases and are typically not met by popular search heuristics.In this paper, we introduce a more...... restricted black-box model for optimisation of pseudo-Boolean functions which we claim captures the working principles of many randomised search heuristics including simulated annealing, evolutionary algorithms, randomised local search, and others. The key concept worked out is an unbiased variation operator...

  6. HOT 2012

    DEFF Research Database (Denmark)

    Lund, Henriette Romme

    Undersøgelse af, hvad der er hot - og hvad der burde være hot på læseområdet med 21 læsekyndige. Undersøgelsen er gennemført siden 2010. HOT-undersøgelsen er foretaget af Nationalt Videncenter for Læsning - Professionshøjskolerne i samarb. med Dansklærerforeningen......Undersøgelse af, hvad der er hot - og hvad der burde være hot på læseområdet med 21 læsekyndige. Undersøgelsen er gennemført siden 2010. HOT-undersøgelsen er foretaget af Nationalt Videncenter for Læsning - Professionshøjskolerne i samarb. med Dansklærerforeningen...

  7. Decommissioning of hot cells using a hydraulically powered servo manipulator

    International Nuclear Information System (INIS)

    Asquith, J.D.; Loughborough, D.

    1993-01-01

    This paper describes the preparations and initial trials involved in remotely dismantling the containment boxes within two concrete shielded hot cells at Harwell Laboratory using a hydraulically powered servo manipulator, ARTISAN. The manipulator deploys a variety of tools for cutting operations. The modular design has enabled it to be specifically configured for this application by adjusting the link lengths using spacers between the joints. In addition to the remote handling requirements, a new posting and ventilation system for the facility is outlined. Trials with ARTISAN in an in-active mock-up have now been successfully completed, and the manipulator is installed in the active facility. The considerations and approach adopted in this project are typical of many situations where remote techniques are required for decommissioning activities. (author)

  8. Evaluation method for the deformation of channel box

    International Nuclear Information System (INIS)

    Sadaoka, Noriyuki; Kumahora, Hiroki; Miki, Kazuyoshi.

    1990-01-01

    In a BWR type nuclear reactor, a channel box undergoes creep deformation due to the effects of a pressure difference between inside and outside of the channel box and a reactor water temperature, which is accelerated by the irradiation of radiation rays and the extent of which depends on the loading position. Then, there are provided a step of determining the extent of the deformation of the channel box in a burning period in the past, a step of setting the loading position for the channel box in the reactor core, a step of forecasting the extent of the deformation of the channel box based on the data of reactor core characteristics, the date of the physical properties of the materials and the shape of the channel box, the data of the loading pattern of fuel assemblies and the extent of deformation, and a step of estimating whether the forecast deforming extent is within an allowable range or not. As a result, the deforming extent for each of the channel boxes can be forecast and, accordingly, the interference with the control rods can be estimated accurately. (N.H.)

  9. Fuel element box inspection device

    International Nuclear Information System (INIS)

    Ortmayer, R.M.; Pick, W.

    1985-01-01

    The invention concerns a device for inspecting the outer geometry of a long fuel element box by measuring the surface contours over its longitudinal crossection and along its length by sensors. These are kept in a sledge which can be moved along the fuel element guide in a slot guide. The measurement signals reach an evaluation device outside the longitudinal box. (orig./HP) [de

  10. Neurochemical aftermath of amateur boxing.

    Science.gov (United States)

    Zetterberg, Henrik; Hietala, M Albert; Jonsson, Michael; Andreasen, Niels; Styrud, Ewa; Karlsson, Ingvar; Edman, Ake; Popa, Cornel; Rasulzada, Abdullah; Wahlund, Lars-Olof; Mehta, Pankaj D; Rosengren, Lars; Blennow, Kaj; Wallin, Anders

    2006-09-01

    Little solid information is available on the possible risks for neuronal injury in amateur boxing. To determine whether amateur boxing and severity of hits are associated with elevated levels of biochemical markers for neuronal injury in cerebrospinal fluid. Longitudinal study. Referral center specializing in evaluation of neurodegenerative disorders. Fourteen amateur boxers (11 men and 3 women) and 10 healthy male nonathletic control subjects. The boxers underwent lumbar puncture 7 to 10 days and 3 months after a bout. The control subjects underwent LP once. Neurofilament light protein, total tau, glial fibrillary acidic protein, phosphorylated tau, and beta-amyloid protein 1-40 (Abeta([1-40])) and 1-42 (Abeta([1-42])) concentrations in cerebrospinal fluid were measured. Increased levels after a bout compared with after 3 months of rest from boxing were found for 2 markers for neuronal and axonal injury, neurofilament light protein (mean +/- SD, 845 +/- 1140 ng/L vs 208 +/- 108 ng/L; P = .008) and total tau (mean +/- SD, 449 +/- 176 ng/L vs 306 +/- 78 ng/L; P = .006), and for the astroglial injury marker glial fibrillary acidic protein (mean +/- SD, 541 +/- 199 ng/L vs 405 +/- 138 ng/L; P = .003). The increase was significantly higher among boxers who had received many hits (>15) or high-impact hits to the head compared with boxers who reported few hits. In the boxers, concentrations of neurofilament light protein and glial fibrillary acidic protein, but not total tau, were significantly elevated after a bout compared with the nonathletic control subjects. With the exception of neurofilament light protein, there were no significant differences between boxers after 3 months of rest from boxing and the nonathletic control subjects. Amateur boxing is associated with acute neuronal and astroglial injury. If verified in longitudinal studies with extensive follow-up regarding the clinical outcome, analyses of cerebrospinal fluid may provide a scientific basis for

  11. Superiority of triple-detector single-photon emission tomography over single- and dual-detector systems in the minimization of motion artefacts

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Taki, Junichi; Michigishi, Takatoshi; Tonami, Norihisa

    1998-01-01

    A patient motion-related artefact is one of the most important artefacts in single-photon emission tomography (SPET) imaging. This study evaluated the effect of the number and configuration of SPET detectors on motion artefacts. The following acquisition conditions were simulated based on original 360 projection images: (1) single-detector 180 rotation (S180), (2) a dual-detector rectangular (L-shaped) 180 acquisition (D180L), (3) dual-detector cameras mounted opposite each other with 360 acquisition (D360) and (4) triple-detector 360 acquisition (T360). The motion artefacts were introduced using a syringe and a myocardial phantom. Clinical cases with technetium-99m methoxyisobutylisonitrile and thallium-201 studies were analysed to confirm the validity of this phantom simulation. The effect of continuous alternate rotation acquisition and summing the projections on the reduction of motion artefacts was investigated in each model. The effect of motion depended on the number and the configuration of the SPET detectors. A 1-pixel (6.4 mm) motion in the S180, D180L and D360 models generated only slight artefacts, and a 2-pixel motion led to an apparent decrease in activity or created hot areas in the myocardium. On the other hand, a T360 rotation created few artefacts even with a 2-pixel motion of the last quarter of the projections. Despite the difference in attenuation with 201 Tl and 99m Tc, similar artefact patterns were observed with both radionuclides in selected patient model studies. Continuous alternate rotation could reduce artefacts caused by less than a 2-pixel motion. In conclusion, calculating the average of the sum of the projections of triple-detector 360 rotations with alternate rotation is the best method to minimize motion artefacts. This ''averaging'' effect of motion artefacts is a key to this simulation. (orig.)

  12. 30 CFR 18.49 - Connection boxes on machines.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Connection boxes on machines. 18.49 Section 18..., AND APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.49 Connection boxes on machines. Connection boxes used to facilitate replacement...

  13. 49 CFR 178.513 - Standards for boxes of natural wood.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Standards for boxes of natural wood. 178.513... natural wood. (a) The following are the identification codes for boxes of natural wood: (1) 4C1 for an ordinary box; and (2) 4C2 for a box with sift-proof walls. (b) Construction requirements for boxes of...

  14. Structural testing of the technology integration box beam

    Science.gov (United States)

    Griffin, C. F.

    1992-01-01

    A full-scale section of a transport aircraft wing box was designed, analyzed, fabricated, and tested. The wing box section, which was called the technology integration box beam, contained blade stiffened covers and T-stiffened channel spars constructed using graphite/epoxy materials. Covers, spars, and the aluminum ribs were assembled using mechanical fasteners. The box beam was statically tested for several loading conditions to verify the stiffness and strength characteristics of the composite wing design. Failure of the box beam occurred at 125 percent of design limit load during the combined upbending and torsion ultimate design load test. It appears that the failure initiated at a stiffener runout location in the upper cover which resulted in rupture of the upper cover and portions of both spars.

  15. Accounting for Dark Current Accumulated during Readout of Hubble's ACS/WFC Detectors

    Science.gov (United States)

    Ryon, Jenna E.; Grogin, Norman A.; Coe, Dan A.; ACS Team

    2018-06-01

    We investigate the properties of excess dark current accumulated during the 100-second full-frame readout of the Advanced Camera for Surveys (ACS) Wide Field Channel (WFC) detectors. This excess dark current, called "readout dark", gives rise to ambient background gradients and hot columns in each ACS/WFC image. While readout dark signal is removed from science images during the bias correction step in CALACS, the additional noise from the readout dark is currently not taken into account. We develop a method to estimate the readout dark noise properties in ACS/WFC observations. We update the error (ERR) extensions of superbias images to include the appropriate noise from the ambient readout dark gradient and stable hot columns. In recent data, this amounts to about 5 e-/pixel added variance in the rows farthest from the WFC serial registers, and about 7 to 30 e-/pixel added variance along the stable hot columns. We also flag unstable hot columns in the superbias data quality (DQ) extensions. The new reference file pipeline for ACS/WFC implements these updates to our superbias creation process.

  16. Box Plots in the Australian Curriculum

    Science.gov (United States)

    Watson, Jane M.

    2012-01-01

    This article compares the definition of "box plot" as used in the "Australian Curriculum: Mathematics" with other definitions used in the education community; describes the difficulties students experience when dealing with box plots; and discusses the elaboration that is necessary to enable teachers to develop the knowledge…

  17. Construction and properties of Box-Behnken designs

    OpenAIRE

    Jo, Jinnam

    1992-01-01

    Box-Behnken designs are used to estimate parameters in a second-order response surface model (Box and Behnken, 1960). These designs are formed by combining ideas from incomplete block designs (BIBD or PBIBD) and factorial experiments, specifically 2k full or 2k-1 fractional factorials. In this dissertation, a more general mathematical formulation of the Box-Behnken method is provided, a general expression for the coefficient matrix in the least squares analysis for estimatin...

  18. ArduiPod Box: a low-cost and open-source Skinner box using an iPod Touch and an Arduino microcontroller.

    Science.gov (United States)

    Pineño, Oskar

    2014-03-01

    This article introduces the ArduiPod Box, an open-source device built using two main components (i.e., an iPod Touch and an Arduino microcontroller), developed as a low-cost alternative to the standard operant conditioning chamber, or "Skinner box." Because of its affordability, the ArduiPod Box provides an opportunity for educational institutions with small budgets seeking to set up animal laboratories for research and instructional purposes. A pilot experiment is also presented, which shows that the ArduiPod Box, in spite of its extraordinary simplicity, can be effectively used to study animal learning and behavior.

  19. A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector. Final-Report

    International Nuclear Information System (INIS)

    Miyaoka, Robert S.

    2012-01-01

    The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support 15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using a novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.

  20. Designing key-dependent chaotic S-box with larger key space

    International Nuclear Information System (INIS)

    Yin Ruming; Yuan Jian; Wang Jian; Shan Xiuming; Wang Xiqin

    2009-01-01

    The construction of cryptographically strong substitution boxes (S-boxes) is an important concern in designing secure cryptosystems. The key-dependent S-boxes designed using chaotic maps have received increasing attention in recent years. However, the key space of such S-boxes does not seem to be sufficiently large due to the limited parameter range of discretized chaotic maps. In this paper, we propose a new key-dependent S-box based on the iteration of continuous chaotic maps. We explore the continuous-valued state space of chaotic systems, and devise the discrete mapping between the input and the output of the S-box. A key-dependent S-box is constructed with the logistic map in this paper. We show that its key space could be much larger than the current key-dependent chaotic S-boxes.

  1. Design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes. Final report

    International Nuclear Information System (INIS)

    1982-01-01

    The project scope of work included the complete decontamination and decommissioning (D and D) of the Westinghouse ARD Fuel Laboratories at the Cheswick Site in the shortest possible time. This has been accomplished in the following four phases: (1) preparation of documents and necessary paperwork; packaging and shipping of all special nuclear materials in an acceptable form to a reprocessing agency; (2) decontamination of all facilities, glove boxes and equipment; loading of generated waste into bins, barrels and strong wooden boxes; (3) shipping of al bins, barrels and boxes containing waste to the designated burial site; removal of all utility services from the laboratories; and (4) final survey of remaining facilities and certification for nonrestricted use; preparation of final report. This attachment contains design of strong wooden box coated with fiberglass reinforced resin for shipping and burial of contaminated glove boxes

  2. A study on the temperature distribution in the hot leg pipe

    International Nuclear Information System (INIS)

    Choe, Yoon-Jae; Baik, Se-Jin; Jang, Ho-Cheol; Lee, Byung-Jin; Im, In-Young; Ro, Tae-Sun

    2003-01-01

    In the hot leg pipes of reactor coolant system of the Korean Standard Nuclear Power Plant (KSNP), a non-uniform distribution in temperature has been observed across the cross-section, which is attributed to the non-uniformity of power distribution in the reactor core usually having a peak in the center region, and to the colder coolant bypass flow through the reactor vessel outlet nozzle clearances. As a result, the arithmetic mean temperature of four Resistance Temperature Detectors (RTDs) installed in each hot leg - two in the upper region and two in the lower region around the pipe wall may not correctly represent the actual coolant bulk temperature. It is also believed that there is a skewness in the velocity profile in the hot leg pipe due to the sudden changes in the flow direction and area from the core to the hot leg pipe, through the reactor vessel outlet plenum. These temperature non-uniformity and velocity skewness affect the measurement of the plant parameter such as the reactor coolant flow rate which is calculated by using the bulk temperature of hot leg pipes. A computational analysis has been performed to simulate the temperature and velocity distributions and to evaluate the uncertainty of temperature correction offset in the hot leg pipe. A commercial CFD code, FLUENT, is used for this analysis. The analysis results are compared with the operational data of KSNP and the scaled-down model test data for System 80. From the comparisons, an uncertainty of correction offset is obtained to measure the bulk temperature of hot leg more accurately, which can be also applied to the operating plants, leading to the reduction of temperature measurement uncertainty. Since the uncertainty of temperature in the hot leg pipe is one of major parameters to calculate the uncertainty of the reactor coolant flow rate, the analysis results can contribute to the improvement of the plant performance and safety by reducing the uncertainty of temperature measurement

  3. Light Therapy Boxes for Seasonal Affective Disorder

    Science.gov (United States)

    Seasonal affective disorder treatment: Choosing a light therapy box Light therapy boxes can offer an effective treatment for seasonal affective disorder. Features such as light intensity, safety, cost and ...

  4. Study of the structure of intermetalics from Fe - Al system after the hot rolling

    Directory of Open Access Journals (Sweden)

    M. Jabłońska

    2015-10-01

    Full Text Available This paper presents the results of structure analysis of Fe - Al alloys after hot rolling deformation. Microstructure analysis were performed before and after deformation using a scanning transmission electron microscopy (STEM technique. The detailed quantities research of the structures was conducted using scanning electron microscopy (SEM equipped with the gun with cold field emission and the detector of electron back scattering diffraction (EBSD.

  5. Implementation of T-box/T/sup -1/-box based AES design on latest xilinx fpga

    International Nuclear Information System (INIS)

    Kundi, D.E.; Aziz, A.

    2015-01-01

    This work presents an efficient implementation of the AES (Advance Encryption Standard) based on Tbox/T-1-box design for both the encryption and decryption on FPGA (Field Programmable Gate Array). The proposed architecture not only make efficient use of full capacity of dedicated 32 Kb BRAM (Block RAM) of latest Xilinx FPGAs (Virtex-5, Virtex-6 and 7 Series) but also saves considerable amount of BRAM and logical resources by using multiple accesses from single BRAM in one cycle of system clock as compared to conventional LUT (Look-Up-Table) techniques. The proposed T-box/T-1-box based AES design for both the encryption and decryption fits into just 4 BRAMs on FPGA and results in good efficiency TPS (Throughput per Slice) with less power consumption. (author)

  6. Search for technihadrons in pp collisions at sqrts=7 TeV with the ATLAS detector

    CERN Document Server

    The ATLAS collaboration

    2011-01-01

    The search for the technivector mesons hoT and omegaT produced in pp collisions at sqrts=7TeV and decaying to the dielectron and dimuon final states is presented. The analysis uses 1.08 ifb (1.21 ifb) of data for the ee (mumu) channel collected with the ATLAS detector at the CERN LHC. Since the hoT and omegaT are narrow, spin 1 resonances, the search uses the limit results of the ATLAS Z′ search. No evidence for a technihadron signal is observed. Within the context of the low-scale technicolor model, masses of the hoT and omegaT from 130−480GeV are excluded at 95% CL for piT masses from 50−480GeV.

  7. Hydrogen atom within spherical boxes with penetrable walls

    International Nuclear Information System (INIS)

    Ley-Koo, E.; Rubinstein, S.

    1979-01-01

    We study a model for the hydrogen atom confined within spherical boxes with penetrable walls. The potential consists of the Coulomb potential inside the box and a constant potential outside the box; the Schroedinger equation admits analytical solutions in both regions. The energy eigenvalues and eigenfunctions for the lowest states of the system are determined numerically for boxes of different sizes and penetrabilities. In addition, we also evaluate the hyperfine splitting, nuclear magnetic shielding, polarizability and pressure of the system and investigate the effect of the confinement on these atomic properties

  8. A novel heuristic method for obtaining S-boxes

    International Nuclear Information System (INIS)

    Chen Guo

    2008-01-01

    An efficient algorithm named chaotic multi-swapping and simulated annealing (CMSSA) for obtaining cryptographically strong 8 x 8 S-boxes is presented. The method is based on chaotic maps and simulated annealing. In addition, cryptographic properties such as bijectivity, strict avalanche criterion, nonlinearity, output bits independence criterion and equiprobable input/output XOR distribution are analyzed in detail for the S-box produced. The results of numerical analysis show that the box has nearly fulfilled the criteria for a cryptographically strong S-box and can effectively resist several attacks

  9. Electrical requirements for unshielded glove boxes

    International Nuclear Information System (INIS)

    1978-02-01

    The specification relates to the general design and installation of electrical services required in unshielded glove boxes in which atmospheres of air, argon or nitrogen etc. may exist either temporarily or permanently. The specification does not apply to electrical services for glove boxes with flammable explosive atmospheres. (author)

  10. Boxing Injuries from an Instructional Program.

    Science.gov (United States)

    Welch, Michael J.; And Others

    1986-01-01

    This paper describes the safeguards as well as the injury pattern of the boxing program at the US Military Academy at West Point from 1983 to 1985. About 2,100 cadets received boxing instruction during this period with an injury rate of less than four percent. (Author/MT)

  11. A study of dissipative phenomena using Orion, a 4 π sectorized neutron detector

    International Nuclear Information System (INIS)

    Galin, J.; Guerreau, D.; Morjean, M.; Pouthas, J.; Saint-Laurent, F.; Sokolov, A.; Wang, X.M.; Piasecki, E.; Charvet, J.L.; CEA Centre d'Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette

    1990-01-01

    When studying the behavior of hot nuclei, the challenge is twofold: how are they formed in nucleus-nucleus collisions and how do they decay. For heavy and, thus neutron rich systems a large fraction of the thermalized energy is evacuated by neutron evaporation. Therefore the numbering, event-wise, of neutrons, over 4 π, gives a strong handle on energy dissipation for the different reaction channels. The first neutron measurements of this kind were performed using spherical detectors made of two hemispheres. Since then, a new and larger 4 π detector, ORION, has been designed in order to get information on the spatial distribution of the neutrons. The main characteristics of ORION are described and a few examples are given in order to illustrate the capabilities of such a detector in the study of dissipative collisions

  12. Prohibiting Headgear for Safety in Amateur Boxing? Opinion of the Canadian Boxing Community: an Online Poll.

    Science.gov (United States)

    Dickinson, Philip; Rempel, Philip

    In 2013, the Amateur International Boxing Association (AIBA) introduced a rule banning headgear for male-senior open class boxers during competition. The AIBA has defended the rule change as motivated by safety and supported by internal unpublished studies. As a result, in 2018, the AIBA plans to universally prohibit headgear in competition: for all competitors (male and female), all ages and all levels. Within Canada, this ruling has generated controversy in the boxing community, yet there has been no overall measure of opinion. To address this, we instituted a voluntary, anonymous, online open-access poll to allow members of the boxing community to express their stance on headgear use in competition. In total, 636 responses were received. A total of 71.5 % of Canadian respondents believed headgear should be mandatory at all levels. Only 5.8 % agreed that headgear should be prohibited, as planned for 2018. Estimating results on a representative breakdown of boxing membership in Canada, a similar pattern emerged, whereby 68.2 % concurred with mandatory headgear while only 4.95 % supported its prohibition. Parents of boxers were almost unanimously against banning headgear, stating they would change sports as a result. Similarly, only 1.7 % of women believed headgear should be prohibited. The consensus of the Canadian boxing community largely opposes the rule changes that the AIBA has implemented. The results highlight risks posed to the long-term viability of the sport, if significant grassroots safety concerns are disregarded.

  13. 49 CFR 178.514 - Standards for plywood boxes.

    Science.gov (United States)

    2010-10-01

    ... identification code for a plywood box is 4D. (b) Construction requirements for plywood boxes are as follows: (1..., commercially dry and free from defects that would materially lessen the strength of the box. The strength of the material used and the method of construction must be appropriate to the capacity and intended use...

  14. 47 CFR 90.241 - Radio call box operations.

    Science.gov (United States)

    2010-10-01

    ... remains on for a period in excess of three minutes. The automatic cutoff system must be designed so the... Public Safety Pool for highway call box systems subject to the following requirements: (1) Call box... effective radiated power (ERP). (3) The height of a call box antenna may not exceed 6.1 meters (20 feet...

  15. Decommissioning of the Risoe Hot Cell facility

    International Nuclear Information System (INIS)

    Carlsen, H.

    1994-06-01

    Nuclear fuels have been handled and examined after irradiation by physical and chemical techniques, and radiotherapy sources, mainly 60 Co, have been produced at Risoe National Laboratory since 1964. The aims of decommissioning (during 1990-94, at IAEA Stage 2 level for reactors) were to obtain safe conditions for the remaining parts of the facility and to produce clean space areas for new projects. The facility comprises 6 concrete cells, several lead-shielded steel cells, glove boxes, shielded storage for waste, a remotely operated optical microscope, a frogman area for personnel access to the concrete cells, a decontamination facility, workshops and safety installations. All steel cells, glove boxes and the microscope were emptied and removed. The concrete cells were emptied of fissile material, scientific equipment, general tools and scrap. Decontamination should facilitate waste packing and reduce amount of waste to be stored temporarily at the Risoe waste treatment facility together with highly active waste. The concrete cells were cleaned remotely by wiping, hot spot removal, by mechanical means and vacuum cleaning. The interiors of 2 cells were decontaminated by high pressure water jetting. All master-slave manipulators and part of the contaminated ventilation system at the cells were removed. The cells are left in a non-ventilated state, connected to the atmosphere by an absolute filter. The main contaminants measured before cell closure were 60 Co, 137 Cs and alpha-emitters. Dismantling, decontamination waste disposal and received doses are described. Simple techniques involving low doses were found to be very effective. (AB)

  16. Dual detector neutron lifetime log: theory and practical applications

    International Nuclear Information System (INIS)

    Serpas, C.J.; Wichmann, P.A.; Fertl, W.H.; DeVries, M.R.; Rndall, R.R.

    1977-01-01

    The Neutron Lifetime Log instrumentation has continued to evolve and now is equipped with dual detectors for increased ease in gas detection and also a ratio response for a simultaneous porosity determination. A good deal of experimentation was involved to minimize both lithology and salinity effects on the porosity indication. This paper contains a discussion of the theory and concepts related to the application of the Dual Detector Neutron Lifetime Log (DNLL). It is important to note that with these advances the recording of thermal neutron capture cross section (Σ) remains consistent with the past measurements of earlier generations of instruments as the most accurate determination of this parameter. A number of field examples of the newly logged results are shown. These field cases include Dual Detector NLL's run thru the drill strings of highly deviated holes when difficulties were encountered in getting conventional open hole logs to bottom, logs thru open perforations and hot radioactive zones, comparisons of the large and small diameter instruments, logs with anomalous fluids in the annulus, logs thru multiple casing strings, and a number of other examples

  17. Hot Flashes

    Science.gov (United States)

    Hot flashes Overview Hot flashes are sudden feelings of warmth, which are usually most intense over the face, neck and chest. Your skin might redden, as if you're blushing. Hot flashes can also cause sweating, and if you ...

  18. A novel F-box protein CaF-box is involved in responses to plant hormones and abiotic stress in pepper (Capsicum annuum L.).

    Science.gov (United States)

    Chen, Rugang; Guo, Weili; Yin, Yanxu; Gong, Zhen-Hui

    2014-02-10

    The F-box protein family is characterized by an F-box motif that has been shown to play an important role in regulating various developmental processes and stress responses. In this study, a novel F-box-containing gene was isolated from leaves of pepper cultivar P70 (Capsicum annuum L.) and designated CaF-box. The full-length cDNA is 2088 bp and contains an open reading frame of 1914 bp encoding a putative polypeptide of 638 amino acids with a mass of 67.8 kDa. CaF-box was expressed predominantly in stems and seeds, and the transcript was markedly upregulated in response to cold stress, abscisic acid (ABA) and salicylic acid (SA) treatment, and downregulated under osmotic and heavy metal stress. CaF-box expression was dramatically affected by salt stress, and was rapidly increased for the first hour, then sharply decreased thereafter. In order to further assess the role of CaF-box in the defense response to abiotic stress, a loss-of-function experiment in pepper plants was performed using a virus-induced gene silencing (VIGS) technique. Measurement of thiobarbituric acid reactive substances (TBARS) and electrolyte leakage revealed stronger lipid peroxidation and cell death in the CaF-box-silenced plants than in control plants, suggesting CaF-box plays an important role in regulating the defense response to abiotic stress resistance in pepper plants.

  19. Interspecific and intraspecific spatial separation by birds breeding in nest boxes

    Directory of Open Access Journals (Sweden)

    Denis C. Deeming

    2017-12-01

    Full Text Available Nest boxes can be seen as a conservation tool for improving low-grade nesting habitat but it is unclear how sympatric species using boxes establish a spatial distribution relative to conspecifics and heterospecifics. This study determined the distances between nest boxes occupied by Blue Tits (Cyanistes caeruleus and Great Tits (Parus major in two British woodlands to ascertain whether spatial distribution was affected by species and, if it was, whether there were reproductive consequences of this breeding distribution. Occupancy of nest boxes at two woodland sites were recorded on an annual basis between 2010 and 2014, inclusive. Distances between nest boxes, and reproductive activity, were recorded. Even if nest boxes showed a clumped distribution in the woodlands, the occupancy of the boxes was random. Not all boxes were used and the minimum distance between occupied boxes was at least twice the distance between boxes in general. Blue Tits tended to have greater distances between boxes containing conspecifics but distances between boxes containing heterospecifics were generally of comparable lengths. Reproductive output was only affected in relation to clutch size for Blue Tits nesting at one site. Nest boxes that aim to improve habitats that lack suitable nesting sites should be placed to reflect actual dispersal distances of the focal bird species.

  20. The application of photoconductive detectors to the measurement of x-ray production in laser produced plasmas

    International Nuclear Information System (INIS)

    Kania, D.R.; Bell, P.; Trebes, J.

    1987-08-01

    Photoconductive detectors (PCDs) offer an attractive alternative for the measurement of pulsed x-rays from laser produced plasmas. These devices are fast (FWHM ∼100 ps), sensitive and simple to use. We have used InP, GaAs, and Type IIa diamond as PCDs to measure x-rays emission from 100 eV to 100 keV. Specifically, we have used these detectors to measure total radiation yields, corona temperatures, and hot electron generated x-rays from laser produced plasmas. 5 refs., 4 figs

  1. Two particle states in an asymmetric box

    OpenAIRE

    Li, Xin; Liu, Chuan

    2004-01-01

    The exact two-particle energy eigenstates in an asymmetric rectangular box with periodic boundary conditions in all three directions are studied. Their relation with the elastic scattering phases of the two particles in the continuum are obtained. These results can be viewed as a generalization of the corresponding formulae in a cubic box obtained by L\\"uscher before. In particular, the s-wave scattering length is related to the energy shift in the finite box. Possible applications of these f...

  2. Two particle states in an asymmetric box

    International Nuclear Information System (INIS)

    Li Xin; Liu Chuan

    2004-01-01

    The exact two-particle energy eigenstates in an asymmetric rectangular box with periodic boundary conditions in all three directions are studied. Their relation with the elastic scattering phases of the two particles in the continuum are obtained. These results can be viewed as a generalization of the corresponding formulae in a cubic box obtained by Luescher before. In particular, the s-wave scattering length is related to the energy shift in the finite box. Possible applications of these formulae are also discussed

  3. The Aerogel Čerenkov detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab

    Science.gov (United States)

    Horn, T.; Mkrtchyan, H.; Ali, S.; Asaturyan, A.; Carmignotto, M.; Dittmann, A.; Dutta, D.; Ent, R.; Hlavin, N.; Illieva, Y.; Mkrtchyan, A.; Nadel-Turonski, P.; Pegg, I.; Ramos, A.; Reinhold, J.; Sapkota, I.; Tadevosyan, V.; Zhamkochyan, S.; Wood, S. A.

    2017-01-01

    Hadronic reactions producing strange quarks such as the exclusive p (e , e ‧K+) Λ and p (e , e ‧K+)Σ0 reactions, or the semi-inclusive p (e , e ‧K+) X reaction, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer (HMS), will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n=1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching ∼10-2 proton and 10-3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ∼12 for n=1.030, ∼8 for n=1.020, ∼10 for n=1.015, and ∼5.5 for n=1.011. The design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.

  4. Methodology of hot nucleus calorimetry and thermometry produced by nuclear reactions around Fermi energies; Methodologie de la calorimetrie et de la thermometrie des noyaux chauds formes lors de collisions nucleaires aux energies de Fermi

    Energy Technology Data Exchange (ETDEWEB)

    Vient, E

    2006-12-15

    This work deals with the calorimetry and thermometry of hot nuclei produced in collisions Xe + Sn between 25 and 100 MeV/u. The apparatus for hot nucleus physical characterization is the 4{pi} detector array Indra. This study was made by using the event generators Gemini, Simon and Hipse and a data-processing filter simulating the complete operation of the multi-detector. The first chapter presents the different ways of producing hot nuclei. In the second and third chapters, the author presents a critical methodological study of calorimetry and thermometry applied to hot nuclei, different methods are reviewed, their accuracy and application range are assessed. All the calorimetry methods rely on the assumption that we are able to discriminate decay products of the hot nucleus from evaporated particles. In the fourth chapter, the author gives some ways of improving calorimetry characterization of the hot nucleus. An alternative method of calorimetry is proposed in the fifth chapter, this method is based on the experimental determination of an evaporation probability that is deduced from the physical characteristics of the particles present in a restricted domain of the space of velocities.

  5. New approaches to glove box design at Hanford

    International Nuclear Information System (INIS)

    Lini, D.C.; Fisher, F.D.; Walters, F.F.

    1986-01-01

    Glove boxes provide the primary environmental containment system for plutonium processing operations at US Dept. of Energy (DOE)-owned facilities such as Rockwell Hanford. As noted in previous presentations, glove box designs and operations have evolved through stages that are a result of advances in processing techniques, new regulatory requirements, and cost escalation. These factors will continue to influence the current glove box designs and operations. The purpose of this presentation is to discuss required upgrades and changes that are being incorporated into glove boxes being installed at Rockwell Hanford and other DOE installations or are being evaluated for future upgrades

  6. Design of housing file box of fire academy based on RFID

    Science.gov (United States)

    Li, Huaiyi

    2018-04-01

    This paper presents a design scheme of intelligent file box based on RFID. The advantages of RFID file box and traditional file box are compared and analyzed, and the feasibility of RFID file box design is analyzed based on the actual situation of our university. After introducing the shape and structure design of the intelligent file box, the paper discusses the working process of the file box, and explains in detail the internal communication principle of the RFID file box and the realization of the control system. The application of the RFID based file box will greatly improve the efficiency of our school's archives management.

  7. Vector boson and quarkonia production in lead-lead collisions with ATLAS detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00015179; The ATLAS collaboration

    2017-01-01

    Photons and weak bosons do not interact strongly with the dense and hot medium formed in the nuclear collisions, thus should be sensitive to the nuclear modification of parton distribution functions (nPDFs). The in-medium modification of heavy quarkonium states plays an important role in studying the hot and dense medium formed in the larger collision systems. The ATLAS detector at the LHC, optimized for searching for new physics in proton-proton collisions, is especially well equipped to measure photons, Z, W bosons and quarkonia in the high occupancy environment produced in heavy-ion collisions. We present recent results on Z boson and charmonia yields as a functions of centrality, transverse momentum, and rapidity, from the ATLAS experiment.

  8. Quantification in positron emission mammography (PEM) with planar detectors: contrast resolution measurements using a custom breast phantom and novel spherical hot-spots

    Science.gov (United States)

    Murthy, K.; Jolly, D.; Aznar, M.; Thompson, C. J.; Sciascia, P.; Loutfi, A.; Lisbona, R.; Gagnon, J. H.

    1999-12-01

    The authors have previously demonstrated that their Positron Emission Mammography-1 (PEM-1) system can successfully detect small (water. The heated solution is poured into spherical molds which are separated upon congealing to yield robust wall-less radioactive hot-spots. The hot-spots were uniform to within 1-5 parts in 100. Less than 0.1% of the total hot-spot activity leaked into the background in 30 minutes. Contrast resolution experiments have been performed with 12 mm and 16 mm diameter hot-spots in the breast phantom containing water with various amounts of background activity. In both cases, the observed contrast values agree well with the ideal values. In the case of the 12 mm hot-spot with a 350-650 keV energy window, image contrast differed from the ideal by an average of 11%. The image contrast for 12 mm hot-spot improved by 40% and the number of detected events decreased by 35% when the low energy threshold was increased from 300 keV to 450 keV.

  9. Dendrimer-encapsulated nanoparticle-core micelles as a modular strategy for particle-in-a-box-in-a-box nanostructures

    NARCIS (Netherlands)

    Hove, ten J.B.; Wang, J.; Leeuwen, van F.W.B.; Velders, A.H.

    2017-01-01

    The hierarchically controlled synthesis and characterization of self-assembling macromolecules and particles are key to explore and exploit new nanomaterials. Here we present a versatile strategy for constructing particle-in-a-box-in-a-box systems by assembling dendrimer-encapsulated gold

  10. Calibration of the hard x-ray detectors for the FOXSI solar sounding rocket

    Science.gov (United States)

    Athiray, P. S.; Buitrago-Casas, Juan Camilo; Bergstedt, Kendra; Vievering, Juliana; Musset, Sophie; Ishikawa, Shin-nosuke; Glesener, Lindsay; Takahashi, Tadayuki; Watanabe, Shin; Courtade, Sasha; Christe, Steven; Krucker, Säm.; Goetz, Keith; Monson, Steven

    2017-08-01

    The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket experiment conducts direct imaging and spectral observation of the Sun in hard X-rays, in the energy range 4 to 20 keV. These high-sensitivity observations are used to study particle acceleration and coronal heating. FOXSI is designed with seven grazing incidence optics modules that focus X-rays onto seven focal plane detectors kept at a 2m distance. FOXSI-1 was flown with seven Double-sided Si Strip Detectors (DSSD), and two of them were replaced with CdTe detectors for FOXSI-2. The upcoming FOXSI-3 flight will carry DSSD and CdTe detectors with upgraded optics for enhanced sensitivity. The detectors are calibrated using various radioactive sources. The detector's spectral response matrix was constructed with diagonal elements using a Gaussian approximation with a spread (sigma) that accounts for the energy resolution of the detector. Spectroscopic studies of past FOXSI flight data suggest that the inclusion of lower energy X-rays could better constrain the spectral modeling to yield a more precise temperature estimation of the hot plasma. This motivates us to carry out an improved calibration to better understand the finer-order effects on the spectral response, especially at lower energies. Here we report our improved calibration of FOXSI detectors using experiments and Monte-Carlo simulations.

  11. Software sensors based on the grey-box modelling approach

    DEFF Research Database (Denmark)

    Carstensen, J.; Harremoës, P.; Strube, Rune

    1996-01-01

    In recent years the grey-box modelling approach has been applied to wastewater transportation and treatment Grey-box models are characterized by the combination of deterministic and stochastic terms to form a model where all the parameters are statistically identifiable from the on......-box model for the specific dynamics is identified. Similarly, an on-line software sensor for detecting the occurrence of backwater phenomena can be developed by comparing the dynamics of a flow measurement with a nearby level measurement. For treatment plants it is found that grey-box models applied to on......-line measurements. With respect to the development of software sensors, the grey-box models possess two important features. Firstly, the on-line measurements can be filtered according to the grey-box model in order to remove noise deriving from the measuring equipment and controlling devices. Secondly, the grey...

  12. Development of a test device to characterize thermal protective performance of fabrics against hot steam and thermal radiation

    International Nuclear Information System (INIS)

    Su, Yun; Li, Jun

    2016-01-01

    Steam burns severely threaten the life of firefighters in the course of their fire-ground activities. The aim of this paper was to characterize thermal protective performance of flame-retardant fabrics exposed to hot steam and low-level thermal radiation. An improved testing apparatus based on ASTM F2731-11 was developed in order to simulate the routine fire-ground conditions by controlling steam pressure, flow rate and temperature of steam box. The thermal protective performance of single-layer and multi-layer fabric system with/without an air gap was studied based on the calibrated tester. It was indicated that the new testing apparatus effectively evaluated thermal properties of fabric in hot steam and thermal radiation. Hot steam significantly exacerbated the skin burn injuries while the condensed water on the skin’s surface contributed to cool down the skin tissues during the cooling. Also, the absorbed thermal energy during the exposure and the cooling was mainly determined by the fabric’s configuration, the air gap size, the exposure time and the existence of hot steam. The research provides a effective method to characterize the thermal protection of fabric in complex conditions, which will help in optimization of thermal protection performance of clothing and reduction of steam burn. (paper)

  13. Black holes in a box

    International Nuclear Information System (INIS)

    Witek, Helvi; Cardoso, Vitor; Nerozzi, Andrea; Gualtieri, Leonardo; Herdeiro, Carlos; Zilhao, Miguel; Sperhake, Ulrich

    2010-01-01

    The evolution of BHs in 'confining boxes' is interesting for a number of reasons, particularly because it mimics some aspects of anti-de Sitter spacetimes. These admit no Cauchy surface and are a simple example of a non-globally hyperbolic spacetime. We are here interested in the potential role that boundary conditions play in the evolution of a BH system. For that, we imprison a binary BH in a box, at which boundary we set mirror-like boundary conditions.

  14. Identifying competencies of boxing coaches

    Directory of Open Access Journals (Sweden)

    Ioannis Tasiopoulos

    2014-10-01

    Full Text Available The purpose of this study was to find out the management skills required by boxing coaches to administrate their clubs. For the purposes of this study a scale was constructed which was answered by 98 boxing coaches. Explanatory factor analysis revealed seven factors: Communication-public relations (5 items, event management (4 items, management techniques (4 items, new technologies (4 items, prevention-safety (2 items, sport (5 items and sports facilities (2 items. The Cronbach of the scale was 0.85. The five competencies that rated by the coaches were: Supervisors of the area of training, maintaining excellent communication with athletes, using new technologies (e-mail, internet, handling disciplinary matters, accidents, complaints and reports on some sporting games and promoted harmony among athletes. We concluded that boxing coaches understand that the competencies required for meeting their obligations, were related to sports, prevention, safety and communications-public relations.

  15. View at the inside of the VELO-vessel: the RF-box with slots for the 2 Pile-Up and 21 VELO-modules. Also visible are the 2 ion getter pumps below the vessel and the belt that drives the x-movement of the module base.

    CERN Multimedia

    Jans, E

    2007-01-01

    Inside of the C-side of the VELO-vessel: the RF-box with slots for the 2 Pile-Up and 21 VELO-modules Interieur du cote C du vaisseau Velo.Transport in the pit towards the balcony.Lifting of the detector half out of the transport trolley.The detector half is being rotated over 90 degrees.The detector half ready to be lowered and mounted on the installation rail.Simultaneous fixation of the 3 bolts that connect the module base to the translation system.A-side of the VELO after installation of the detector half and before installation of the repeater crates.

  16. Hot nuclei studied with high efficiency neutron detectors

    International Nuclear Information System (INIS)

    Galin, J.

    1990-01-01

    We have shown the invaluable benefit that a high efficiency 4π neutron detector can bring to the study of reaction mechanisms following collisions of heavy nuclei at intermediate energy. Analysis requires Monte-Carlo simulations for comparison between experimental data and any emission model. In systematic measurements with projectiles of velocity corresponding to energies between 27 and 77 MeV/u, where both the influence of beam velocity and mass have been investigated separately, it has been shown that the projectile-target mass asymmetry, much more than velocity, has a decisive influence on energy dissipation. The closer the projectile mass to the target mass, the more energy is dissipated per unit mass of the considered projectile plus target system. The latter presents all the characteristics of a thermalized system, evaporating a copious number of light particles: up to about 40 neutrons (after efficiency correction) and 11 light charged particles in the most dissipative collisions between Kr+Au, and 90 neutrons for Pb+U with a yet unknown number of l.c.p. In the Kr experiment, these particles are isotropically emitted in the frame of a fused system, excited with 1.2 GeV. Moreover, l.c.p. exhibit Maxwellian energy distributions as in any standard evaporation process. We are now eager to better characterize the properties of the Pb+Au (U) systems for which about 1/3 of the neutrons are freed in a rather large fraction of all collisions. The thermalized energy should then approach very closely the total binding energy of the two interacting nuclei

  17. Techniques employed for detection of hot particles in the marine environment

    International Nuclear Information System (INIS)

    Pillsbury, G D

    2007-01-01

    During the decommissioning of the Maine Yankee nuclear plant, several methods were developed and employed to survey for hot particles in the marine environment surrounding the site. The methods used and the sensitivities achieved in the search for environmentally dispersed particles during the various decommissioning activities performed are described in detail. Surveys were performed on dry soil, exposed marine sediment and submerged marine sediment. Survey techniques ranged from the use of the basic NaI detector coupled to a count rate meter to an intrinsic germanium detector deployed in a submarine housing coupled to a multi-channel analyser. The initial surveys consisted of collecting samples of marine sediment, spreading them out over a 1 m 2 surface in a thin layer, and scanning the deposited sediment by hand using a 5 cm by 5 cm NaI detector coupled to a standard count rate meter. This technique was later replaced by walkover scans with the 5 cm by 5 cm NaI detector moved in a serpentine pattern over the sediment surface. By coupling the detector to a 'smart meter', an alarm set point could be used to alert the surveyor to the presence of a particle within the instrument's field of view. A similar technique, with the detector mounted in a watertight housing secured to the end of a pole, was also employed to scan underwater locations. The most sensitive method developed for performing underwater surveys was the use of the intrinsic germanium detector placed in a submarine housing. Detailed descriptions of the methods employed and the results obtained are presented. This work demonstrates that there are several approaches to surveying for discrete particles in the marine environment and the relative merits of each are considered

  18. HOT 2011

    DEFF Research Database (Denmark)

    Lund, Henriette Romme

    En undersøgelse af, hvad der er hot - og burde være hot på læseområdet. I undersøgelsen deltager 21 læsekyndige fra praksisfeltet, professionshøjskolerne og forskningsområdet.......En undersøgelse af, hvad der er hot - og burde være hot på læseområdet. I undersøgelsen deltager 21 læsekyndige fra praksisfeltet, professionshøjskolerne og forskningsområdet....

  19. Air-tighten test for used glove boxes

    International Nuclear Information System (INIS)

    Itoh, Masanori; Kashiro, Kashio; Matsumoto, Masaki; Ogiya, Takashi; Nakata, Keiji; Gohda, Masahiko

    2000-05-01

    All of the glove boxes in Plutonium Fuel Fabrication facilities are operated after confirming their condition by conducting negative pressure maintenance test and air-tighten test. Although we check the negative pressure maintenance condition before operating glove boxes in a daily basis, we have not been conducted the air-tighten test. Hence, we have conduct air-tighten test using the glove box that will be dismantled in the near future. In order to compare the present data to the criteria of licensing and to the measurement data for new glove box, the test was conducted by leak tightness vessel which is used the competent authority's test for newly constructed equipments. We also have confirmed the leakage condition in case failure of keeping negative pressure. The main results are as follows: 1. No leakage was detected after leaving the glove box 21 days in case failure of keeping negative pressure condition. 2. The measurement result of the air-tighten test was 0.025 vol%/h, and it was confirmed that this result is within the range of licensing criteria (-0.04 - 0.06 vol%/h). 3. The measurement result was also within the error of leak tightness vessel, and it was confirmed that the air-tighten condition was in force within this past 10 years after installing this glove box (the corresponding value for used the competent authority test for newly constructed equipments was 0.019 vol%/h). (author)

  20. MUON DETECTORS: RPC

    CERN Multimedia

    P. Paolucci

    2013-01-01

    During LS1, the Resistive Plate Chamber (RPC) collaboration is focusing its efforts on installation and commissioning of the fourth endcap station (RE4) and on the reparation and maintenance of the present system (1100 detectors). The 600 bakelite gaps, needed to build 200 double-gap RE4 chambers are being produced in Korea. Chamber construction and testing sites are located at CERN, in Ghent University, and at BARC (India). At present, 42 chambers have been assembled, 32 chambers have been successfully tested with cosmic rays runs and 7 Super Modules, made by two chambers, have been built at CERN by a Bulgarian/Georgian/Italian team and are now ready to be installed in the positive endcap. The 36 Super Modules needed to complete the positive endcap will be ready in September and installation is scheduled for October 2013. The Link-Board system for RE4 is under construction in Naples. Half of the system has been delivered at CERN in June. Six crates (Link-Board Boxes) and 75 boards, needed to instrument t...

  1. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    CERN Document Server

    Croft, S; Chard-Mj, P; Estop, J R; Martancik, D; Sheila-Melton; Young, B

    2003-01-01

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nucli...

  2. Eye trauma in boxing.

    Science.gov (United States)

    Corrales, Gustavo; Curreri, Anthony

    2009-10-01

    In boxing, along with a few other sports, trauma is inherent to the nature of the sport; therefore it is considered a high-risk sport for ocular injuries. The long-term morbidity of ocular injuries suffered by boxers is difficult to estimate due to the lack of structured long-term follow-up of these athletes. Complications of blunt ocular trauma may develop years after the athlete has retired from the ring and is no longer considered to be at risk for boxing-related injuries. This article describes the wide range of eye injuries a boxer can sustain, and their immediate and long-term clinical management.

  3. A Study on Temperature Distribution in the Hot Leg Pipes considering the Variation of Flow Rate in RCS

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyuksu; Yi, Kunwoo; Choe, Yoonjae; Jang, Hocheol; Yune, Seokjeong; Park, Seongchan [KEPCO Engineering and Construction, Daejeon (Korea, Republic of)

    2016-10-15

    In this study, a computational analysis is performed to predict the deviation in the temperature distribution in the hot leg pipe according to the flow rate variation in RCS. In the hot leg pipes of Reactor Coolant System (RCS) of APR1400, four Resistance Temperature Detectors (RTDs), to obtain the average hot leg temperature, are installed at each hot leg pipe (two in the upper region and the other two in the lower region around the wall of the hot leg pipe). There is a deviation in temperature distribution in the hot leg pipe due to the sudden changes in the flow direction and area from the reactor core exit to the hot leg pipe. The non-uniform temperature distribution in the hot leg pipe can affect the measurement of the plant parameters such as the reactor power and the reactor coolant flow rate. The following conclusions are reached 1) The non-uniform temperature distribution in the core exit is sustained to some extent through the entire region of hot leg pipe. 2) The temperature ranges having a uniform pattern are 45 - 120° and 240 - 315°. The sensor positions of RTDs are located in this interval (45 - 120° and 240 - 315°) and this sensor positions of RTDs show the appropriate temperature measurement. Also, the temperature distribution shows the similar pattern without reference to the flow rate variation in RCS.

  4. Fuel assembly, channel box of fuel assembly, fuel spacer of fuel assembly and method of manufacturing channel box

    International Nuclear Information System (INIS)

    Chaki, Masao; Kanazawa, Toru; Orii, Akihito; Nagayoshi, Takuji; Nishida, Koji; Kawasaki, Terufumi.

    1997-01-01

    In a fuel assembly of a BWR type reactor, fuel rods disposed at corners of side walls of a channel box or in the periphery of the side walls are partially removed, and recessed portions are formed on the side walls of the channel box from which the fuel rods are removed. Spaces closed at the sides are formed in the inner side of the corner portions. Openings are formed for communicating the closed space with the outside of the channel box. Then, the channel area of the outer side of the channel box is increased, through which much water flows to increase the amount of water in the reactor core thereby promoting the moderation of neutrons and providing thermal neutrons suitable to nuclear fission. The degree of freedom for distribution of the spaces in the reactor core is increased to improve neutron economy thereby enabling to utilize reactor fuels effectively. (N.H.)

  5. 49 CFR 230.103 - Tender roller bearing journal boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Tender roller bearing journal boxes. 230.103... Locomotives and Tenders Running Gear § 230.103 Tender roller bearing journal boxes. Tender roller bearing journal boxes shall be maintained in a safe and suitable condition. ...

  6. Decontamination and dismantling of large plutonium-contamined glove boxes

    International Nuclear Information System (INIS)

    Draulans, J.

    1991-01-01

    This report describes the work performed in the frame of two C.E.C. - Contracts FI1D-002400-B Decommissioning of very large glove boxes and FI1D-0058 Decommissioning of a complex glove box structure to be dismounted partially on place. Detailed information is given about each glove box. The selection of the solution Transportation of the glove boxes to a specialized dismantling plant is justified. The necessary contacts inside the BELGONUCLEAIRE MOX plant and between the latter and other organizations are explained. The problems of manipulating large gloves are listed and the retained solution of building a so called Stiffening frame around each glove box is described. Furthermore information is given concerning required operators time for cleaning, manipulating, packing and dismantling together with received doses and quantities of waste produced. Concerning the glove box unit partially to be dismounted on place, detailed information is given about the way the glove boxes have been treated prior to this partial dismantling on place and about the way this partial dismantling has been performed. From these results one can conclude that such a delicate task can be performed without major difficulties. Finally information is given of the decontamination test of a highly Pu contaminated glove box with freon with rather poor results and of the preliminary CO 2 blasting tests on non active samples

  7. Resonant plasmonic terahertz detection in vertical graphene-base hot-electron transistors

    Energy Technology Data Exchange (ETDEWEB)

    Ryzhii, V. [Research Institute of Electrical Communication, Tohoku University, Sendai 980-8577 (Japan); Center for Photonics and Infrared Engineering, Bauman Moscow State Technical University and Institute of Ultra High Frequency Semiconductor Electronics of RAS, Moscow 111005 (Russian Federation); Otsuji, T. [Research Institute of Electrical Communication, Tohoku University, Sendai 980-8577 (Japan); Ryzhii, M. [Department of Computer Science and Engineering, University of Aizu, Aizu-Wakamatsu 965-8580 (Japan); Mitin, V. [Department of Electrical Engineering, University at Buffalo, SUNY, Buffalo, New York 1460-1920 (United States); Shur, M. S. [Department of Electrical, Computer, and System Engineering and Physics, Applied Physics, and Astronomy, Rensselaer Polytechnic Institute, Troy, New York 12180 (United States)

    2015-11-28

    We analyze dynamic properties of vertical graphene-base hot-electron transistors (GB-HETs) and consider their operation as detectors of terahertz (THz) radiation using the developed device model. The GB-HET model accounts for the tunneling electron injection from the emitter, electron propagation across the barrier layers with the partial capture into the GB, and the self-consistent oscillations of the electric potential and the hole density in the GB (plasma oscillations), as well as the quantum capacitance and the electron transit-time effects. Using the proposed device model, we calculate the responsivity of GB-HETs operating as THz detectors as a function of the signal frequency, applied bias voltages, and the structural parameters. The inclusion of the plasmonic effect leads to the possibility of the GB-HET operation at the frequencies significantly exceeding those limited by the characteristic RC-time. It is found that the responsivity of GB-HETs with a sufficiently perfect GB exhibits sharp resonant maxima in the THz range of frequencies associated with the excitation of plasma oscillations. The positions of these maxima are controlled by the applied bias voltages. The GB-HETs can compete with and even surpass other plasmonic THz detectors.

  8. Outside the box

    International Nuclear Information System (INIS)

    Pichon, Max

    2011-01-01

    Full text: Queensland-based Hydrasyst wants to take its motto of 'Do more with less' into the greywater sector with a new water recycling and energy recovery technology launched in November, called The Grey Box. The company is initially targeting large industrial laundries as they are major generators of greywater and heavy energy users, but it has ambitions well beyond that. The average commercial laundry consumes 1-5ML of water a week, using about 16 litres for every 1kg of clothing washed. Hydrasyst director Stephen Balemi said The Grey Box can slash the volume by 80 per cent. While he was reluctant to disclose too much technical detail, he claimed it is the only technology serving the $1 billion a year laundry sector that combines microfiltration / ultrafiltration membrane technology and energy reduction components. The heart of the system is a ceramic hollow fibre membrane. Balemi said it produces higher filtrate quality than competitors, meaning the recycled water can be reused more often, and can process feed water of up to 70°C compared to typical ultrafiltration membranes that cap out at about 38°C. This means the recycled water can be reused at higher temperatures, with the heat in it recovered by a precise steam heater built into The Grey Box. “As an overall measure, it saves 80 per cent of the water that is processed and saves 20 per cent of the energy,” Balemi said. Four systems have already been installed, with one going into a large commercial laundry in south Queensland and another to AMP's state-of-the-art 6 Green Star building in Brisbane. “We can modify them slightly to suit the industry, depending on the quality of raw water they are trying to recycle and also depending on the size of the project,,” said Balemi. Where many organisations build systems to specification, The Grey Box is offered in three standard sizes: the HY20 (20kL per day, based on a 10 hour day), HY80 (80kL per day) and HY130 (130kL per day). They can be used

  9. Increase of hot initial plasma energy content in the end system of AMBAL-M during hydrogen puffing

    International Nuclear Information System (INIS)

    Akhmetov, Timour; Bekher, Sergei; Davydenko, Vladimir; Krivenko, Aleksander; Muraviev, Maksim; Reva, Vladimir; Sokolov, Vladimir

    2001-01-01

    At the end system of the completely axisymmetric mirror trap AMBAL-M the experiments on creation and study of a hot initial plasma have been performed. In the experiments a gas-box was used for hydrogen supply into the hot startup plasma in the mirror trap to increase the plasma density. The hot initial plasma in the trap was produced by the trapping of a plasma stream with developed electrostatic turbulence generated by a gas-discharge source located outside the entrance throat. It was found that in addition to the increase in the plasma density by a factor of 2-3, hydrogen puffing resulted in an unexpected nearly twofold diamagnetism increase. The gas puffing did not reduce the electron temperature in the trap. Essential for explanation of the observed effect is the fact that with the gas puffing the measured plasma potential in the trap increased. The increase in the plasma potential enhanced the trapping of the ion flow entering the trap and increased the average energy of the electron flow entering the trap. It was found that with the increasing hydrogen puffing rate plasma parameters in the trap were saturated. (author)

  10. MADS-box gene evolution - structure and transcription patterns

    DEFF Research Database (Denmark)

    Johansen, Bo; Pedersen, Louise Buchholt; Skipper, Martin

    2002-01-01

    Mads-box genes, ABC model, Evolution, Phylogeny, Transcription patterns, Gene structure, Conserved motifs......Mads-box genes, ABC model, Evolution, Phylogeny, Transcription patterns, Gene structure, Conserved motifs...

  11. A Lithium Vapor Box Divertor Similarity Experiment

    Science.gov (United States)

    Cohen, Robert A.; Emdee, Eric D.; Goldston, Robert J.; Jaworski, Michael A.; Schwartz, Jacob A.

    2017-10-01

    A lithium vapor box divertor offers an alternate means of managing the extreme power density of divertor plasmas by leveraging gaseous lithium to volumetrically extract power. The vapor box divertor is a baffled slot with liquid lithium coated walls held at temperatures which increase toward the divertor floor. The resulting vapor pressure differential drives gaseous lithium from hotter chambers into cooler ones, where the lithium condenses and returns. A similarity experiment was devised to investigate the advantages offered by a vapor box divertor design. We discuss the design, construction, and early findings of the vapor box divertor experiment including vapor can construction, power transfer calculations, joint integrity tests, and thermocouple data logging. Heat redistribution of an incident plasma-based heat flux from a typical linear plasma device is also presented. This work supported by DOE Contract No. DE-AC02-09CH11466 and The Princeton Environmental Institute.

  12. Energy and time of flight measurements of REX-ISOLDE stable beams using Si detectors

    CERN Document Server

    Cantero, E D; Fraser, M A; Lanaia, D; Sosa, A; Voulot, D; Zocca, F

    2014-01-01

    In this paper we present energy and time spectroscopy measurements for the stable beams of REX-ISOLDE obtained using Si detectors. By using an alpha source as a calibration reference, the absolute energy E of stable beam particles (A/q = 4) was determined in spectroscopy mode in the energy range 1 MeV < E < 8 MeV (0.30 MeV/u < E/A < 1.87 MeV/u). The time of flight of the beam particles (2.18 MeV/u < E/A < 2.27 MeV/u) was determined by installing identical Si detectors in two diagnostic boxes separated by 7.7 m. The results obtained with these two techniques are compared with the values obtained by dipole scans using a bending magnet. The measurements took place between January and February of 2013.

  13. Fire test of DOT 7A Boxes

    International Nuclear Information System (INIS)

    Jensen, J.D.

    1979-05-01

    The primary objective of conducting the full-scale fire tests of the DOT (Department of Transportation) 7A FRP Boxes was to provide information to assist in quantifying the fire hazard of the storage located at the Radioactive Waste Management Complex (RWMC), and to learn if changing the storage array will decrease the fire risk. Also, the level of fire fighting and fire protection required to maintain the risk at the RWMC within acceptable DOE guidelines was investigated. Two full-scale fire tests were conducted at Southwest Research Institute (SwRI) in June 1978, using the DOE 7A FRP Plywood Storage Containers. The fire tests showed that when subjected to a substantial ignition source, the boxes will propagate fire as long as no fire-suppression measures are taken. Fire will breach the boxes and spread the radioactive contaminated waste if it is not extinguished. As the fire progresses, additional boxes will become involved, and eventually the entire storage array will ignite. It is recommended that the use of DOT 7A Boxes be discontinued and replaced with noncombustible storage containers. In the event this is not practicable, guidance recommendations are presented to minimize the large fire loss potential. It is also recommended that an investigation be conducted into the number of boxes that can be destroyed and still maintain a safe environment for employees and the public. This investigation should include how far radioactive contamination will spread, what cleanup will be required, anticipated exposure of the people within the area, and the public impact of such a fire

  14. Hadron scattering in an asymmetric box

    International Nuclear Information System (INIS)

    Li Xin; Chen Ying; Meng Guozhan; Feng Xu; Gong Ming; He Song; Li Gang; Liu Chuan; Liu Yubin; Ma Jianping; Meng Xiangfei; Shen Yan; Zhang Jianbo

    2007-01-01

    We propose to study hadron-hadron scattering using lattice QCD in an asymmetric box which allows one to access more non-degenerate low-momentum modes for a given volume. The conventional Luescher's formula applicable in a symmetric box is modified accordingly. To illustrate the feasibility of this approach, pion-pion elastic scattering phase shifts in the I = 2, J = 0 channel are calculated within quenched approximation using improved gauge and Wilson fermion actions on anisotropic lattices in an asymmetric box. After the chiral and continuum extrapolation, we find that our quenched results for the scattering phase shifts in this channel are consistent with the experimental data when the three-momentum of the pion is below 300MeV. Agreement is also found when compared with previous theoretical results from lattice and other means. Moreover, with the usage of asymmetric volume, we are able to compute the scattering phases in the low-momentum range (pion three momentum less than about 350MeV in the center of mass frame) for over a dozen values of the pion three-momenta, much more than using the conventional symmetric box with comparable volume

  15. DFBX boxes -- electrical and cryogenic distribution boxes for the superconducting magnets in the LHC straight sections

    International Nuclear Information System (INIS)

    Zbasnik, Jon P.; Corradi, Carol A.; Gourlay, S.A.; Green, MichaelA.; Hafalia, Aurelio Q.; Kajiyama, Yoichi Jr.; Knolls, Michael J.; LaMantia, Roberto F.; Rasson, Joseph E.; Reavill, Dulie; Turner, William C.

    2002-01-01

    DFBX distribution boxes provide cryogenic and electrical services to superconducting quadrupoles and to a superconducting dipole at either end of four of the long straight sections in the LHC. The DFBX boxes also provide instrumentation and quench protection to the magnets. Current for the quadrupole and the dipole magnet is delivered through leads that combine HTS and gas cooled leads. Current for the 600 A and 120 A correction magnets is provided by pure gas-cooled leads. The bus bars from the leads to the magnets pass through low leak-rate lambda plugs between 1.8 K and 4.4 K. The heat leak into the 1.9 K region from the liquid helium tank is determined by the design of the lambda plugs. This paper describes the DFBX boxes and their function of delivering current and instrumentation signals to the magnets

  16. HOT 2014

    DEFF Research Database (Denmark)

    Lund, Henriette

    Undersøgelse af, hvad der er hot - og hvad der burde være hot på læseområdet med 21 læsekyndige. Undersøgelsen er gennemført siden 2010. HOT-undersøgelsen er foretaget af Nationalt Videncenter for Læsning - Professionshøjskolerne i samarb. med Dansklærerforeningen...

  17. Lightweight S-Box Architecture for Secure Internet of Things

    Directory of Open Access Journals (Sweden)

    A. Prathiba

    2018-01-01

    Full Text Available Lightweight cryptographic solutions are required to guarantee the security of Internet of Things (IoT pervasiveness. Cryptographic primitives mandate a non-linear operation. The design of a lightweight, secure, non-linear 4 × 4 substitution box (S-box suited to Internet of Things (IoT applications is proposed in this work. The structure of the 4 × 4 S-box is devised in the finite fields GF (24 and GF ((222. The finite field S-box is realized by multiplicative inversion followed by an affine transformation. The multiplicative inverse architecture employs Euclidean algorithm for inversion in the composite field GF ((222. The affine transformation is carried out in the field GF (24. The isomorphic mapping between the fields GF (24 and GF ((222 is based on the primitive element in the higher order field GF (24. The recommended finite field S-box architecture is combinational and enables sub-pipelining. The linear and differential cryptanalysis validates that the proposed S-box is within the maximal security bound. It is observed that there is 86.5% lesser gate count for the realization of sub field operations in the composite field GF ((222 compared to the GF (24 field. In the PRESENT lightweight cipher structure with the basic loop architecture, the proposed S-box demonstrates 5% reduction in the gate equivalent area over the look-up-table-based S-box with TSMC 180 nm technology.

  18. Cloning and analysis of two Ceratopteris thalictroides MADS-box genes

    Directory of Open Access Journals (Sweden)

    XU Daolan

    2014-06-01

    Full Text Available MADS-box transcription factors,as a large gene family,play an important role in plant growth and development,especially act as key regulators in controlling the identities of floral organs in flowering plants.They are also significant in the evolutionary revelation.In order to understand MADS-box genes,we need more information of MADS-box genes in non flowering plant.MADS-box genes of Ceratopteris thalictroides were selected to clone and analysis by using RACE method.Two MADS-box genes,designated CtMADS1 and CtMADS2 in C. thalictroides,were cloned.Analysis indicates that CtMADS1 is belonged to MIKC*-clade,while CtMADS2 is belonged to MIKCc-clade.Phylogeny suggests that these two MADS-box genes of C. thalictroides have a close relationship with flowering plants,the data indicates that at least two different MADS-box genes are homologous to floral homeotic genes existed in the last common ancestor of contemporary vascular plants.

  19. The Roles of T-Box Genes in Vertebrate Limb Development.

    Science.gov (United States)

    Sheeba, C J; Logan, M P O

    2017-01-01

    Members of the T-box gene family have diverse roles during embryogenesis and many play critical roles in the developing limb. This is exemplified by the fact that, in humans, mutations in T-box genes are associated with several congenital syndromes that include limb defects as part of their characteristic spectrum of abnormalities. T-box genes encode for evolutionary conserved transcription factors that include both transcriptional activators and repressors. The hallmark of T-box gene members is the presence of the eponymous DNA-binding T-box domain. There are 17 mammalian T-box genes, which based on the sequence homology of the T-box domain, are grouped into five subfamilies, namely, T, Tbx1, Tbx2, Tbx6, and Tbr1. At least nine T-box genes are expressed during limb development with distinct and dynamic expression patterns. All four members of Tbx2 subfamily (Tbx2, Tbx3, Tbx4, Tbx5) and three members of Tbx1 (Tbx1, Tbx15, Tbx18), Brachyury (T) and Eomes (Tbr2) are expressed in the developing limb. © 2017 Elsevier Inc. All rights reserved.

  20. Boxing against drones : Drones in sports education

    NARCIS (Netherlands)

    Zwaan, S.G.; Barakova, E.I.

    2016-01-01

    This paper investigates how drones could be integrated into the context of sports, boxing in particular. The goal of this project is to design a drone application that allows direct and embodied interaction. The sport of boxing provides a very interesting setting, because the intimidating and

  1. 49 CFR 230.102 - Tender plain bearing journal boxes.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Tender plain bearing journal boxes. 230.102... Locomotives and Tenders Running Gear § 230.102 Tender plain bearing journal boxes. Plain bearing journal boxes... expected to damage the bearing; or have a detrimental effect on the lubrication of the journal and bearing...

  2. Insights into the quality of DnaA boxes and their cooperativity

    DEFF Research Database (Denmark)

    Hansen, Flemming G.; Christensen, Bjarke Bak; Nielsen, Christina Bang

    2006-01-01

    Plasmids carrying the mioC promoter region with its two DnaA boxes are as efficient in titration of DnaA protein as plasmids carrying a replicationinactivated oriC region with its five DnaA boxes. The two DnaA boxes upstream of the mioC promoter were mutated in various ways to study the cooperati......Plasmids carrying the mioC promoter region with its two DnaA boxes are as efficient in titration of DnaA protein as plasmids carrying a replicationinactivated oriC region with its five DnaA boxes. The two DnaA boxes upstream of the mioC promoter were mutated in various ways to study...... the cooperativity between the DnaA boxes, and to study in vivo the in vitrodefined 9mer DnaA box consensus sequence TTA/TTNCACA). The quality and cooperativity of the DnaA oxes were determined in two complementary ways: as titration of DnaA protein leading to derepression of the dnaA promoter, and as repression...... of the mioC promoter caused by the DnaA protein binding to the DnaA boxes. Titration of DnaA protein correlated with repression of the mioC promoter. The level of titration and repression with the normal promoter-proximal box (TTTTCCACA) depends strongly on the presence and the quality of a DnaA box...

  3. Development and trial manufacturing of 1/2-scale partial mock-up of blanket box structure for fusion experimental reactor

    International Nuclear Information System (INIS)

    Hashimoto, Toshiyuki; Takatsu, Hideyuki; Sato, Satoshi

    1994-07-01

    Conceptual design of breeding blanket has been discussed during the CDA (Conceptual Design Activities) of ITER (International Thermonuclear Experimental Reactor). Structural concept of breeding blanket is based on box structure integrated with first wall and shield, which consists of three coolant manifolds for first wall, breeding and shield regions. The first wall must have cooling channels to remove surface heat flux and nuclear heating. The box structure includes plates to form the manifolds and stiffening ribs to withstand enormous electromagnetic load, coolant pressure and blanket internal (purge gas) pressure. A 1/2-scale partial model of the blanket box structure for the outboard side module near midplane is manufactured to estimate the fabrication technology, i.e. diffusion bonding by HIP (Hot Isostatic Pressing) and EBW (Electron Beam Welding) procedure. Fabrication accuracy is a key issue to manufacture first wall panel because bending deformation during HIP may not be small for a large size structure. Data on bending deformation during HIP was obtained by preliminary manufacturing of HIP elements. For the shield structure, it is necessary to reduce the welding strain and residual stress of the weldment to establish the fabrication procedure. Optimal shape of the parts forming the manifolds, welding locations and welding sequence have been investigated. In addition, preliminary EBW tests have been performed in order to select the EBW conditions, and fundamental data on built-up shield have been obtained. Especially, welding deformation by joining the first wall panel to the shield has been measured, and total deformation to build-up shield by EBW has been found to be smaller than 2 mm. Consequently, the feasibility of fabrication technologies has been successfully demonstrated for a 1m-scaled box structure including the first wall with cooling channels by means of HIP, EBW and TIG (Tungsten Inert Gas arc)-welding. (author)

  4. Earthquake resistance test of full-scale glove box

    International Nuclear Information System (INIS)

    Fujita, T.; Ohtani, K.; Hayashi, M.; Kozeki, M.; Ide, T.; Sakuno, K.

    1989-01-01

    A glove box used at nuclear facilities must confine radioactive materials. High airtightness and negative internal pressure are used to prevent leaks. The allowable leakage rate of air is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is kept at - 30 mm H 2 O in normal operation. The glove box structural strength and its confinement reliability during an earthquake are major concerns. The verification of aseismic analysis methods and assumptions for a glove box are thus of great importance. Data on the dynamic behavior of giant glove boxes was recently obtained in large shaker experiments. This paper describes these experimental results and the appropriateness of aseismic analysis methods used in current design

  5. DISTORTION ANALYSIS OF TILL -WALLED BOX GIRDERS

    African Journals Online (AJOL)

    NIJOTECH

    bridges, buildings, motor vehicles, ships and aircrafts. Due to thinness of the box walls, generalized loads applied to this structure give rise to warping and distortion of ..... Recommendation for Design of. Intermediate Diaphragms in Box. Girders, Transactions of Japanese. Society of Civil Engineers, Vol. 14,1984, pp 121-126.

  6. Boxing It Up-a Cross-curricular Approach.

    Science.gov (United States)

    Till, Wesley

    1996-01-01

    Reports on a class project that examined the manufacture of boxes and packaging to teach about design and technology. The class discovered basic manufacturing techniques by examining and disassembling cereal boxes. Field trips to stores provided more examples. Appraises the children's final projects and discusses acquiring materials. (MJP)

  7. Measurements of the electron dose distribution near inhomogeneities using a plastic scintillation detector

    International Nuclear Information System (INIS)

    Wells, C.M.M.; Mackie, T.R.; Podgorsak, M.B.; Holmes, M.A.; Papanikolaou, N.; Reckwerdt, P.J.; Cygler, J.; Rogers, D.W.O.; Bielajew, A.F.; Schmidt, D.G.

    1994-01-01

    Accurate measurement of the electron dose distribution near an inhomogeneity is difficult with traditional dosimeters which themselves perturb the electron field. The authors tested the performance of a new high resolution, water-equivalent plastic scintillation detector which has ideal properties for this application. A plastic scintillation detector with a 1 mm diameter, 3 mm long cylindrical sensitive volume was used to measure the dose distributions behind standard benchmark inhomogeneities in water phantoms. The plastic scintillator material is more water equivalent than polystyrene in terms of its mass collision stopping power and mass scattering power. Measurements were performed for beams of electrons having initial energies of 6 and 18 MeV at depths from 0.2-4.2 cm behind the inhomogeneities. The detector reveals hot and cold spots behind heterogeneities at resolutions equivalent to typical film digitizer spot sizes. Plots of the dose distributions behind air, aluminum, lead, and formulations for cortical and inner bone-equivalent materials are presented. The plastic scintillation detector is suited for measuring the electron dose distribution near an inhomogeneity. 14 refs., 9 figs

  8. Effects of energy conservation on equilibrium properties of hot asymmetric nuclear matter

    Science.gov (United States)

    Zhang, Zhen; Ko, Che Ming

    2018-01-01

    Based on the relativistic Vlasov-Uehling-Uhlenbeck transport model, which includes relativistic scalar and vector potentials on baryons, we consider an N -Δ -π system in a box with periodic boundary conditions to study the effects of energy conservation in particle production and absorption processes on the equilibrium properties of the system. The density and temperature of the matter in the box are taken to be similar to the hot dense matter formed in heavy ion collisions at intermediate energies. We find that to maintain the equilibrium numbers of N ,Δ , and π , which depend on the mean-field potentials of N and Δ , we must include these potentials in the energy conservation condition that determines the momenta of outgoing particles after a scattering or decay process. We further find that the baryon scalar potentials mainly affect the Δ and pion equilibrium numbers, while the baryon vector potentials have considerable effect on the effective charged pion ratio at equilibrium. Our results thus indicate that it is essential to include in the transport model the effect of potentials in the energy conservation of a scattering or decay process, which is ignored in most transport models, for studying pion production in heavy ion collisions.

  9. HOT 2010

    DEFF Research Database (Denmark)

    Lund, Henriette Romme

    En undersøgelse af, hvad der er hot - og burde være hot på læseområdet. I undersøgelsen deltager en række læsekyndige fra praksisfeltet, professionshøjskolerne og forskningsområdet. Undersøgelsen er gentaget hvert år siden 2010.......En undersøgelse af, hvad der er hot - og burde være hot på læseområdet. I undersøgelsen deltager en række læsekyndige fra praksisfeltet, professionshøjskolerne og forskningsområdet. Undersøgelsen er gentaget hvert år siden 2010....

  10. HOT 2013

    DEFF Research Database (Denmark)

    Lund, Henriette Romme

    En undersøgelse af, hvad der er hot - og burde være hot på læseområdet. I undersøgelsen deltager en række læsekyndige fra praksisfeltet, professionshøjskolerne og forskningsområdet. Undersøgelsen er gentaget hvert år siden 2010.......En undersøgelse af, hvad der er hot - og burde være hot på læseområdet. I undersøgelsen deltager en række læsekyndige fra praksisfeltet, professionshøjskolerne og forskningsområdet. Undersøgelsen er gentaget hvert år siden 2010....

  11. Suppression of sawtooth oscillations due to hot electrons and hot ions

    International Nuclear Information System (INIS)

    Zhang, Y.Z.; Berk, H.L.

    1989-01-01

    The theory of m = 1 kink mode stabilization is discussed in the presence of either magnetically trapped hot electrons or hot ions. For instability hot ion requires particles peaked inside the q = 1 surface, while hot electrons require that its pressure profile be increasing at the q = 1 surface. Experimentally observed sawtooth stabilization usually occurs with off-axis heating with ECRH and near axis heating with ICRH. Such heating may produce the magnetically trapped hot particle pressure profiles that are consistent with theory. 17 refs., 2 figs

  12. Fire protection at hot laboratories: Prevention, surveillance and fire-fighting

    International Nuclear Information System (INIS)

    Chappellier, A.M.

    1976-01-01

    After pointing out that fire in a hot laboratory can be an important factor contributing to a radioactivity accident, the author briefly recalls the items to be taken into account in a fire hazard analysis. He then describes various important aspects of prevention, detection and fire-fighting which - at the French Commissariat a l'Energie Atomique - are governed by already defined rules or by guidelines which are sufficiently advanced to give a clear idea of the final conclusions to be drawn therefrom. From the point of view protection, the concept of fire sector has been evolved, at hot laboratories, becomes the fire and contamination sector, so as to ensure under all circumstances the containment of any radioactive materials dispersed in the premises on fire. Regarding fire detection, a study should be made on the constraints specific to the facility and liable to affect detector operation. These include ventilation, radiations, neutral or corrosive atmosphere, etc. As regards fire-fighting, two particular aspects are dealt with, namely the question of using water in case of fire and action to be taken concerning ventilation. A practical example - the protection of a ventilation system - is described. In conclusion the paper refers to the need for a thorough analysis specific to each hot laboratory, and to the importance of preparing an operational plan so as to avoid any dangerous improvisations in case of an accident. (author)

  13. Heavy Ion Physics at the LHC with the ATLAS Detector

    CERN Document Server

    Steinberg, P.

    2007-01-01

    The ATLAS detector at CERN will provide a high-resolution longitudinally-segmented calorimeter and precision tracking for the upcoming study of heavy ion collisions at the LHC (sqrt{s_{NN}=5520 GeV). The calorimeter covers |eta|<5 with both electromagnetic and hadronic sections, while the inner detector spectrometer covers |eta|<2.5. ATLAS will study a full range of observables necessary to characterize the hot and dense matter formed at the LHC. Global measurements (particle multiplicities, collective flow) will provide access into its thermodynamic and hydrodynamic properties. Measuring complete jets out to 100's of GeV will allow detailed studies of energy loss and its effect on jets. Quarkonia will provide a handle on deconfinement mechanisms. ATLAS will also study the structure of the nucleon and nucleus using forward physics probes and ultraperipheral collisions, both enabled by segmented Zero Degree Calorimeters.

  14. Heavy ion physics at the LHC with the ATLAS detector

    International Nuclear Information System (INIS)

    Steinberg, P

    2007-01-01

    The ATLAS detector at CERN will provide a high-resolution longitudinally segmented calorimeter and precision tracking for the upcoming study of heavy ion collisions at the LHC (√s NN = 5520 GeV). The calorimeter covers |η| < 5 with both electromagnetic and hadronic sections, while the inner detector spectrometer covers |η| < 2.5. ATLAS will study a full range of observables necessary to characterize the hot and dense matter formed at the LHC. Global measurements (particle multiplicities, collective flow) will provide access into its thermodynamic and hydrodynamic properties. Measuring complete jets out to 100's of GeV will allow detailed studies of energy loss and its effect on jets. Quarkonia will provide a handle on deconfinement mechanisms. ATLAS will also study the structure of the nucleon and nucleus using forward physics probes and ultraperipheral collisions, both enabled by segmented zero degree calorimeters

  15. Formation and de-excitation of very hot nuclei in Ar + Au collisions at 30 and 60 MeV/nucleon

    International Nuclear Information System (INIS)

    Hamdani, T.

    1993-10-01

    The study of the formation and the de-excitation of very hot nuclei by using collisions between Ar and Au at 30 and 60 MeV/u is presented in this work. The detection system consisted of three multidetectors for fragments (DELF) or light particles (TONNEAU+MUR) plus two groups of four detectors (Silicium, CsI). This system and the triggering conditions adopted allowed the selection of two classes of events: semiperipheral collisions and central collisions. The studies presented using global variables, show clearly that the fragments produced in the reactions are emitted from an equilibrated source. Hence, an event generator based on the statistical model was employed to verify the method of calculation of the excitation energy of the source. It also provides information concerning experimental biases and the sensitivity of some of the global variables used in the experimental analysis. A detailed study of the temperatures of hot nuclei is presented using the data recorded with the CsI detectors. The temperatures measured reached up to 7 MeV for the reaction at 60 MeV/u. (orig.)

  16. A sealed enclosure of the glove box type

    International Nuclear Information System (INIS)

    Moreels, Pierre.

    1974-01-01

    The invention relates to a sealed enclosure of the glove-box type. According to the invention, the box-frame comprises: angle-bars having a right-angled cross-section, sealing joints, tightening bars and fastening means [fr

  17. Prediction and experimental verification of performance of box type solar cooker - Part I. Cooking vessel with central cylindrical cavity

    International Nuclear Information System (INIS)

    Reddy, Avala Raji; Rao, A.V. Narasimha

    2007-01-01

    The performance of conventional box type solar cookers can be improved by better designs of cooking vessels with proper understanding of the heat flow to the material to be cooked. An attempt has been made in this article to arrive at a mathematical model to understand the heat flow process to the cooking vessel and thereby to the food material. The mathematical model considers a double glazed hot box type solar cooker loaded with two different types of vessels, kept either on the floor of the cooker or on lugs. The performance of the cooking vessel with a central cylindrical cavity is compared with that of a conventional cylindrical cooking vessel. It is found from the experiments and modeling that the cooking vessel with a central cylindrical cavity on lugs results in a higher temperature of the thermic fluid than that of a conventional vessel on the floor or on lugs. The average improvement of performance of the vessel with a central cylindrical cavity kept on lugs is found to be 5.9% and 2.4% more than that of a conventional cylindrical vessel on the floor and on lugs, respectively

  18. Meal box schemes a convenient way to avoid convenience food? Uses and understandings of meal box schemes among Danish consumers.

    Science.gov (United States)

    Hertz, Frej Daniel; Halkier, Bente

    2017-07-01

    The term convenience food is subject to diversification, lack of clarity and moral ambiguity. In this paper we address these issues and critically discuss convenience food by using empirical findings from a Danish study that deals with practitioners' uses of meal box schemes. The methodological design consists of thirteen individual interviews, four focus groups and some observations of cooking practices. We combine the empirical findings with a particular definition of convenience food by Brunner et al. (2010) and selected practice theoretical concepts. This particular combination enables us to categorize meal box schemes as a new form of convenience food called convenient food. In addition, results suggest that meal box schemes reduce leftovers from dinner. Meal boxes also influence dinner related activities such as planning ahead in time and grocery shopping, which require less physical and mental effort. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Development of phonon-mediated transition-edge-sensor x-ray detectors for use in astronomy

    Science.gov (United States)

    Leman, Steven W.

    Low temperature detectors have grown in popularity over the years for a variety of reasons. Reduced thermal noise and the associated reduction in statistical fluctuations improve signal to noise. Novel material properties at low temperature such as superconductivity can be exploited. And let us not forget easier access to cryogenic techniques, for example industry made and sold refrigerators eliminating the need for graduate students to make their own. In this thesis I discuss development of a novel phonon-mediated distributed transition-edge-sensor x-ray detector which would be useful for astrophysical studies such as magnetic recombination in the solar corona, the warm-hot intergalactic medium and surveys of clusters and groups of galaxies. The detector uses a large semiconductor absorber and Transition-Edge-Sensors (TESs) to readout the absorbed energy. Calorimetry is performed on individual photons and a partitioning of the energy between various TESs allows for position determination. Hence time varying astronomical sources can be spectroscopically studied and imaged. I will conclude with a discussion of the detector's performance and propose a next generation detector which could make significant improvements on the design discussed in this thesis.

  20. A Group Action Method for Construction of Strong Substitution Box

    Science.gov (United States)

    Jamal, Sajjad Shaukat; Shah, Tariq; Attaullah, Atta

    2017-06-01

    In this paper, the method to develop cryptographically strong substitution box is presented which can be used in multimedia security and data hiding techniques. The algorithm of construction depends on the action of a projective general linear group over the set of units of the finite commutative ring. The strength of substitution box and ability to create confusion is assessed with different available analyses. Moreover, the ability of resistance against malicious attacks is also evaluated. The substitution box is examined by bit independent criterion, strict avalanche criterion, nonlinearity test, linear approximation probability test and differential approximation probability test. This substitution box is equated with well-recognized substitution boxes such as AES, Gray, APA, S8, prime of residue, Xyi and Skipjack. The comparison shows encouraging results about the strength of the proposed box. The majority logic criterion is also calculated to analyze the strength and its practical implementation.

  1. Detector simulation needs for detector designers

    International Nuclear Information System (INIS)

    Hanson, G.G.

    1987-11-01

    Computer simulation of the components of SSC detectors and of the complete detectors will be very important for the designs of the detectors. The ratio of events from interesting physics to events from background processes is very low, so detailed understanding of detector response to the backgrounds is needed. Any large detector for the SSC will be very complex and expensive and every effort must be made to design detectors which will have excellent performance and will not have to undergo major rebuilding. Some areas in which computer simulation is particularly needed are pattern recognition in tracking detectors and development of shower simulation code which can be trusted as an aid in the design and optimization of calorimeters, including their electron identification performance. Existing codes require too much computer time to be practical and need to be compared with test beam data at energies of several hundred GeV. Computer simulation of the processing of the data, including electronics response to the signals from the detector components, processing of the data by microprocessors on the detector, the trigger, and data acquisition will be required. In this report we discuss the detector simulation needs for detector designers

  2. A multi-layer box model of carbon dynamics in soil

    International Nuclear Information System (INIS)

    Kuc, T.

    2005-01-01

    A multi-layer box model (MLB) for quantification of carbon fluxes between soil and atmosphere has been developed. In the model, soil carbon reservoir is represented by two boxes: fast decomposition box (FDB) and slow decomposition box (SDB), characterised by substantially different turnover time (TT) of carbon compounds. Each box has an internal structure (sub-compartments) accounting for carbon deposited in consecutive time intervals. The rate of decomposition of carbon compounds in each sub-compartment is proportional to the carbon content. With the aid of the MLB model and the 14 C signature of carbon dioxide, the fluxes entering and leaving the boxes, turnover time of carbon in each box, and the ratio of mass of carbon in the slow and fast box (M s /M f ) were calculated. The MBL model yields the turnover time of carbon in the FDB (TT f ) ca. 14 for typical investigated soils of temperate climate ecosystems. The calculated contribution of the CO 2 flux originating from the slow box (F s ) to the total CO 2 flux into the atmosphere ranges from 12% to 22%. These values are in agreement with experimental observations at different locations. Assuming that the input flux of carbon (F i n) to the soil system is doubled within the period of 100 years, the soil buffering capacity for excess carbon predicted by the MLB model for typical soil parameters may vary in the range between 26% and 52%. The highest values are obtained for soils characterised by long TTf, and well developed old carbon pool. (author)

  3. A Comparison of Energy Expenditure During "Wii Boxing" Versus Heavy Bag Boxing in Young Adults.

    Science.gov (United States)

    Perusek, Kristen; Sparks, Kenneth; Little, Kathleen; Motley, Mary; Patterson, Sheila; Wieand, Jennifer

    2014-02-01

    Traditional computer videogames are sedentary, whereas new computer videogames, such as the Nintendo(®) (Redmond, WA) "Wii™ Sports" games, allow users to physically interact while playing the sport. Energy expenditure (EE), heart rate (HR), and rating of perceived exertion (RPE) during heavy bag boxing versus the Nintendo "Wii Boxing" game were compared. Fifteen males and 14 females (mean age, 25.6 years; height, 171.3 cm; weight, 71.8 kg) randomly selected (by a coin toss) heavy bag boxing or "Wii Boxing" for their first test session and completed the other protocol at their second session at least 2 days later. Each session lasted for a total duration of 30 minutes and consisted of 10 3-minute exercise bouts with measurements of HR, RPE, and EE obtained from indirect calorimetry. A paired-samples t test was used to analyze the results. Significant differences were found for HR (bag, 156 beats per minute; Wii, 138 beats per minute; P=0.001) and RPE (bag, 13.8; Wii, 11.4; P=0.0001) but not for EE (bag, 8.0 kcal/minute; Wii, 7.1 kcal/minute; bag, 241 total kcal; Wii, 213 total kcal; P=0.078). The results suggest that computer active videogames, such as the Nintendo Wii, have the potential to provide similar EE as their traditional forms of exercise and may be a sufficient replacement for traditional target HR zone activities, especially in less fit individuals. Further research is needed to compare EE for different "Wii Sports" games with those for their traditional forms of exercise.

  4. Influence of twin-screw hot extrusion on linolenic acid retention in flaxseed meal

    International Nuclear Information System (INIS)

    Imran, M.

    2014-01-01

    flaxseed (linum usitatissimum l.) provides multiple nutritional benefits including high quality protein, dietary fiber and is the most abundant source of alpha-linolenic acid (c18:3). This study focuses on the effect of twin-screw hot extrusion on alpha-linolenic acid retention in full-fat flaxseed meal. the ranges of processing variables selected using box-behnken design were barrel exit temperature (bet) of 120-140 degree c; screw speed (ss) of 200-400 rpm; feed rate (fr) of 1-2 kg/h and feed moisture (fm) of 20-30%. The amount of alpha-linolenic acid retention in extruded samples ranged from 89.2% to 99.3%. Optimal operating conditions were stablished; bet (121degree c), ss (388 rpm), fr (1 kg/h) and fm (22.2%) for maximum (99.9%) retention of degree-linolenic acid. This effect was mainly dependent on bet and fm (p degree 0.01), whereas ss and fr imparted a lesser effect (p=0.05). The results of this study demonstrated that the twin-screw hot extrusion can be successfully explored to produce fatty meals with significant fatty acids retention for commercially food or feed purposes. (author)

  5. BOX-COX REGRESSION METHOD IN TIME SCALING

    Directory of Open Access Journals (Sweden)

    ATİLLA GÖKTAŞ

    2013-06-01

    Full Text Available Box-Cox regression method with λj, for j = 1, 2, ..., k, power transformation can be used when dependent variable and error term of the linear regression model do not satisfy the continuity and normality assumptions. The situation obtaining the smallest mean square error  when optimum power λj, transformation for j = 1, 2, ..., k, of Y has been discussed. Box-Cox regression method is especially appropriate to adjust existence skewness or heteroscedasticity of error terms for a nonlinear functional relationship between dependent and explanatory variables. In this study, the advantage and disadvantage use of Box-Cox regression method have been discussed in differentiation and differantial analysis of time scale concept.

  6. HOT STARS WITH HOT JUPITERS HAVE HIGH OBLIQUITIES

    International Nuclear Information System (INIS)

    Winn, Joshua N.; Albrecht, Simon; Fabrycky, Daniel; Johnson, John Asher

    2010-01-01

    We show that stars with transiting planets for which the stellar obliquity is large are preferentially hot (T eff > 6250 K). This could explain why small obliquities were observed in the earliest measurements, which focused on relatively cool stars drawn from Doppler surveys, as opposed to hotter stars that emerged more recently from transit surveys. The observed trend could be due to differences in planet formation and migration around stars of varying mass. Alternatively, we speculate that hot-Jupiter systems begin with a wide range of obliquities, but the photospheres of cool stars realign with the orbits due to tidal dissipation in their convective zones, while hot stars cannot realign because of their thinner convective zones. This in turn would suggest that hot Jupiters originate from few-body gravitational dynamics and that disk migration plays at most a supporting role.

  7. The determination of a neutron source position in an unknown homogeneous medium: The planar case

    International Nuclear Information System (INIS)

    Dubinski, S.; Talmor, A.; Presler, O.; Tshuva, A.; Yaar, I.; Orion, I.; Alfassi, Z.B.

    2005-01-01

    The possibility of localization of an unknown neutron source in various bulky homogeneous media (box) was studied. For the planar case, two 3 He detectors on the opposite faces of the box were used. A constant polypropylene shield around the box and detectors was used to eliminate the varying contribution from the environment to increase count rates of the detectors and to protect the experimentalist. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron detectors positioned on parallel faces of the box, coplanar with the source. The localization requires measurement of the count rate of both the unknown source and an extra source positioned on one of the faces of the box. The localization is based on the finding that the ratio of the count rates of the two detectors is an exponential function of the distance of the source from one of the detectors

  8. Ballast system for maintaining constant pressure in a glove box

    Science.gov (United States)

    Shlichta, Paul J.

    1989-09-01

    A ballast system is disclosed for a glove box including a fixed platform on which is mounted an inflatable bag on top of which resides a cover and a weight. The variable gas volume of the inflatable bag communicates with that of the glove box via a valved tube. The weight and the gas volume are selected to maintain a relatively constant pressure in the glove box despite variations in the glove box volume while avoiding the use of complicated valving apparatus.

  9. British Box Business: A History of OCL

    DEFF Research Database (Denmark)

    Poulsen, René Taudal

    2018-01-01

    Book review of British Box Business: A History of OCL / edited by A. Bott SCARA, Goldaming, 2009, £17 (hb) 288 pages, illustrations, bibliography, index iSBn 139780955922701......Book review of British Box Business: A History of OCL / edited by A. Bott SCARA, Goldaming, 2009, £17 (hb) 288 pages, illustrations, bibliography, index iSBn 139780955922701...

  10. Modern biotechnology Panacea or new Pandora's box?

    NARCIS (Netherlands)

    Tramper, J.; Yang Zhu, Yang

    2011-01-01

    According to Greek mythology Pandora was sent down to earth upon the orders of Zeus. She was given a mysterious box which she was not allowed to open. However, Pandora was very curious and when she arrived on earth she couldn?t help taking a peek inside the box. She saw that it was filled with gifts

  11. Analysis of S-box in Image Encryption Using Root Mean Square Error Method

    Science.gov (United States)

    Hussain, Iqtadar; Shah, Tariq; Gondal, Muhammad Asif; Mahmood, Hasan

    2012-07-01

    The use of substitution boxes (S-boxes) in encryption applications has proven to be an effective nonlinear component in creating confusion and randomness. The S-box is evolving and many variants appear in literature, which include advanced encryption standard (AES) S-box, affine power affine (APA) S-box, Skipjack S-box, Gray S-box, Lui J S-box, residue prime number S-box, Xyi S-box, and S8 S-box. These S-boxes have algebraic and statistical properties which distinguish them from each other in terms of encryption strength. In some circumstances, the parameters from algebraic and statistical analysis yield results which do not provide clear evidence in distinguishing an S-box for an application to a particular set of data. In image encryption applications, the use of S-boxes needs special care because the visual analysis and perception of a viewer can sometimes identify artifacts embedded in the image. In addition to existing algebraic and statistical analysis already used for image encryption applications, we propose an application of root mean square error technique, which further elaborates the results and enables the analyst to vividly distinguish between the performances of various S-boxes. While the use of the root mean square error analysis in statistics has proven to be effective in determining the difference in original data and the processed data, its use in image encryption has shown promising results in estimating the strength of the encryption method. In this paper, we show the application of the root mean square error analysis to S-box image encryption. The parameters from this analysis are used in determining the strength of S-boxes

  12. S-Boxes Based on Affine Mapping and Orbit of Power Function

    Science.gov (United States)

    Khan, Mubashar; Azam, Naveed Ahmed

    2015-06-01

    The demand of data security against computational attacks such as algebraic, differential, linear and interpolation attacks has been increased as a result of rapid advancement in the field of computation. It is, therefore, necessary to develop such cryptosystems which can resist current cryptanalysis and more computational attacks in future. In this paper, we present a multiple S-boxes scheme based on affine mapping and orbit of the power function used in Advanced Encryption Standard (AES). The proposed technique results in 256 different S-boxes named as orbital S-boxes. Rigorous tests and comparisons are performed to analyse the cryptographic strength of each of the orbital S-boxes. Furthermore, gray scale images are encrypted by using multiple orbital S-boxes. Results and simulations show that the encryption strength of the orbital S-boxes against computational attacks is better than that of the existing S-boxes.

  13. Individual TL detector characteristics in automated processing of personnel dosemeters: correction factors as extension to identity codes of dosemeter cards

    International Nuclear Information System (INIS)

    Toivonen, Matti.

    1979-07-01

    One, two and three-component dosemeter cards and their associated processing equipment were developed for personnel monitoring. A novel feature of the TLD system is that the individual sensitivity correction factors of TL detectors for β/γ radiation dosimetry and special timing factors for the readout of neutron detectors are stored on dosemeter cards as an extension of the identity codes. These data are utilized in the automatic TL reading process with the aim of cancelling out the influence of the individual detector characteristics on the measuring results. Stimulation of TL is done with hot nitrogen without removing the detectors from their cards and without any metal contact. Changes in detector characteristics are thus improbable. The reading process can be adjusted in a variety of ways. For example, each detector in the same card can be processed with optimal heating and the specific 250 deg C glow peak of neutron radiation can be roughly separated from the main LiF glow peaks. (author)

  14. Sustainable Energy - Without the hot air

    Science.gov (United States)

    MacIsaac, Dan

    2009-11-01

    Reader John Roeder writes about a website associated with David MacKay's book Sustainable Energy-Without the hot air. The book is a freely downloadable PDF (or purchasable) book describing an analysis detailing a low-carbon renewable energy transformation route for a large, modern first world industrial country (the United Kingdom). Written for the layman, the work uses vernacular language, e.g., energy consumption and production in a series of bar charts detailing the impacts of necessary strategies such as population reduction, lifestyle changes, and technology changes. MacKay notes that most reasonable plans have large nuclear and ``clean coal'' or other carbon capture components, lots of pumped heat, wind, and much efficiency improvement. He debunks some sacred cows (roof-mounted micro-turbines; hydrogen-powered cars) while pointing out simple effective technologies such as roof-mounted solar water heaters. Similar modest changes in the U.S. (painting roofs white in the southern half of the country) have strong impacts. MacKay claims that he ``doesn't advocate any particular plan or technology,'' but ``tells you how many bricks are in the lego box, and how big each brick is'' so readers can start making planning decisions.

  15. Surface reflectance drives nest box temperature profiles and thermal suitability for target wildlife.

    Directory of Open Access Journals (Sweden)

    Stephen R Griffiths

    Full Text Available Thermal properties of tree hollows play a major role in survival and reproduction of hollow-dependent fauna. Artificial hollows (nest boxes are increasingly being used to supplement the loss of natural hollows; however, the factors that drive nest box thermal profiles have received surprisingly little attention. We investigated how differences in surface reflectance influenced temperature profiles of nest boxes painted three different colors (dark-green, light-green, and white: total solar reflectance 5.9%, 64.4%, and 90.3% respectively using boxes designed for three groups of mammals: insectivorous bats, marsupial gliders and brushtail possums. Across the three different box designs, dark-green (low reflectance boxes experienced the highest average and maximum daytime temperatures, had the greatest magnitude of variation in daytime temperatures within the box, and were consistently substantially warmer than light-green boxes (medium reflectance, white boxes (high reflectance, and ambient air temperatures. Results from biophysical model simulations demonstrated that variation in diurnal temperature profiles generated by painting boxes either high or low reflectance colors could have significant ecophysiological consequences for animals occupying boxes, with animals in dark-green boxes at high risk of acute heat-stress and dehydration during extreme heat events. Conversely in cold weather, our modelling indicated that there are higher cumulative energy costs for mammals, particularly smaller animals, occupying light-green boxes. Given their widespread use as a conservation tool, we suggest that before boxes are installed, consideration should be given to the effect of color on nest box temperature profiles, and the resultant thermal suitability of boxes for wildlife, particularly during extremes in weather. Managers of nest box programs should consider using several different colors and installing boxes across a range of both orientations and

  16. Evolving S Boxes with Reduced Differential Power Analysis Susceptibiltiy

    Science.gov (United States)

    2016-12-02

    their applications : proceedings of the second International Conference on Genetic Algorithms : July 28-31, 1987 at the Massachusetts Institute of...relax cryptanalytic constraints to lower S-box leakage, as quantified by the transparency order. We apply genetic algorithms to generate 8-bit S-boxes...single objective genetic algorithms for generating S-boxes than the existing literature. We demonstrate this in the first side-by-side comparison of the

  17. Method for using a channel box for fuel assemblies in a reactor

    International Nuclear Information System (INIS)

    Ito, Ken-ichi; Shinpo, Katsutoshi; Watahiki, Minoru.

    1975-01-01

    Object: To extend a service life of a channel box used in a light water nuclear reactor. Structure: A channel box mounted in the outer periphery of a fuel bundle is removed from the fuel bundle after use for a predetermined period of time, and the removed channel box is re-mounted on the fuel bundle with opposite ends of the box reversed in position for further use. By this arrangement, structural deformation of the channel box may be minimized to extend the service life of the box. (Kamimura, M.)

  18. Simulation based investigation of source-detector configurations for non-invasive fetal pulse oximetry

    Directory of Open Access Journals (Sweden)

    Böttrich Marcel

    2015-09-01

    Full Text Available Transabdominal fetal pulse oximetry is a method to monitor the oxygen supply of the unborn child non-invasively. Due to the measurement setup, the received signal of the detector is composed of photons coding purely maternal and photons coding mixed fetal-maternal information. To analyze the wellbeing of the fetus, the fetal signal is extracted from the mixed component. In this paper we assess source-detector configurations, such that the mixed fetal-maternal components of the acquired signals are maximized. Monte-Carlo method is used to simulate light propagation and photon distribution in tissue. We use a plane layer and a spherical layer geometry to model the abdomen of a pregnant woman. From the simulations we extracted the fluence at the detector side for several source-detector distances and analyzed the ratio of the mixed fluence component to total fluence. Our simulations showed that the power of the mixed component depends on the source-detector distance as expected. Further we were able to visualize hot spot areas in the spherical layer model where the mixed fluence ratio reaches the highest level. The results are of high importance for sensor design considering signal composition and quality for non-invasive fetal pulse oximetry.

  19. PCB-Based Break-Out Box

    Science.gov (United States)

    Lee, Jason H.

    2011-01-01

    Break-out boxes (BOBs) are necessary for all electrical integration/cable checkouts and troubleshooting. Because the price of a BOB is high, and no work can be done without one, often the procedure stops, simply waiting for a BOB. A less expensive BOB would take less time in the integration, testing, and troubleshooting process. The PCB-based BOB works and looks the same as a standard JPL BOB, called Gold Boxes. The only differences between the old BOB and the new PCB-based BOB is that the new one has 80 percent of its circuitry in a printed circuit board. This process reduces the time for fabrication, thus making the BOBs less expensive. Moreover, because of its unique design, the new BOBs can be easily assembled and fixed. About 80 percent of the new PCB-based BOB is in a $22 (at the time of this reporting) custom-designed, yet commercially available PCB. This device has been used successfully to verify that BOB cables were properly made. Also, upon completion, the BOB was beeped out via a multimeter to ensure that all sockets on the connectors were properly connected to the respective banana jack. When compared to the Gold Box BOBs, the new BOB has many advantages. It is much more cost efficient, it delivers equal usability at substantially lower cost of the BOB, and the Gold Box is much heavier when compared to the new BOB. The new BOB is also a bit longer and much more versatile in that connectors are easily changeable and if a banana jack is broken, it can be replaced instead of throwing away an entire BOB.

  20. Study of Randomness in AES Ciphertexts Produced by Randomly Generated S-Boxes and S-Boxes with Various Modulus and Additive Constant Polynomials

    Science.gov (United States)

    Das, Suman; Sadique Uz Zaman, J. K. M.; Ghosh, Ranjan

    2016-06-01

    In Advanced Encryption Standard (AES), the standard S-Box is conventionally generated by using a particular irreducible polynomial {11B} in GF(28) as the modulus and a particular additive constant polynomial {63} in GF(2), though it can be generated by many other polynomials. In this paper, it has been shown that it is possible to generate secured AES S-Boxes by using some other selected modulus and additive polynomials and also can be generated randomly, using a PRNG like BBS. A comparative study has been made on the randomness of corresponding AES ciphertexts generated, using these S-Boxes, by the NIST Test Suite coded for this paper. It has been found that besides using the standard one, other moduli and additive constants are also able to generate equally or better random ciphertexts; the same is true for random S-Boxes also. As these new types of S-Boxes are user-defined, hence unknown, they are able to prevent linear and differential cryptanalysis. Moreover, they act as additional key-inputs to AES, thus increasing the key-space.

  1. Study of tourists exposure rate in Mahallat hot Spring Region

    Energy Technology Data Exchange (ETDEWEB)

    Tavakoli, H. M.B. [Isfahan Univ. of Medical Sciences, Isfahan (Iran, Islamic Republic of); Fallah, M.G. [Isfahan University of Medical Sciences (Iran, Islamic Republic of); Ghiasinejad, M. [Iran Atomic Energy Organization, Tehran (Iran, Islamic Republic of)

    2006-07-01

    Introduction: High level radiation areas have been recognized on various parts of the earth. Some of these areas include: Brasilia, India, and Iran. Mahallat hot spring region in the central part of Iran is also one of these areas. Study of exposure in these areas could be helpful in investigating the effects of ionizing radiation. Materials and Methods: In addition to several seasonal springs, Mahallat hot spring region contains five permanent springs named: Soleimani, Shafa, Dombe, Romatism and Sauda. Internal exposure (due to inhalation of radon gas and drinking water) and external exposure (due to cosmic rays and radioactive elements in the ground) to the tourists was studied. Used materials and apparatus include: RSS -112 ionizing chamber for environmental gamma rays exposure measurement, highly pure germanium detector for measuring radioactive elements in the ground, liquid scintillation counter for measuring {sup 222}Rn gas concentration in water samples, Bubbler chamber and Locus cells for Rn concentration measurements (Emanation method) and Alfa guard detector for {sup 226}Ra concentration measurements. Conclusions and Discussion: A total of 270 visitors are included in this study. Considering residual durations of the studied group in open and closed environment of bathrooms, hotel and inn rooms, obtained annual external effective dose is 75.4{+-}8.7{mu}Sv and 138.3{+-}11.8{mu}Sv for natives and travelers respectively. EEC coefficients has been used for calculating annual internal effective dose due to radon gas inhalation. Annual internal effective dose, in this path, is 0.9 and 2.1 mSv in open and closed environment for native and visitors respectively. Annual internal effective dose due to drinking water, is 0.43 and 0.09{mu}Sv for natives people and travelers, respectively. Measurements show that more than 90% of the received dose in the studied groups is due to radon gas inhalation. External and internal dose summation is 0.98 mSv for natives and 2

  2. Study of tourists exposure rate in Mahallat hot Spring Region

    International Nuclear Information System (INIS)

    Tavakoli, H. M.B.; Fallah, M.G.; Ghiasinejad, M.

    2006-01-01

    Introduction: High level radiation areas have been recognized on various parts of the earth. Some of these areas include: Brasilia, India, and Iran. Mahallat hot spring region in the central part of Iran is also one of these areas. Study of exposure in these areas could be helpful in investigating the effects of ionizing radiation. Materials and Methods: In addition to several seasonal springs, Mahallat hot spring region contains five permanent springs named: Soleimani, Shafa, Dombe, Romatism and Sauda. Internal exposure (due to inhalation of radon gas and drinking water) and external exposure (due to cosmic rays and radioactive elements in the ground) to the tourists was studied. Used materials and apparatus include: RSS -112 ionizing chamber for environmental gamma rays exposure measurement, highly pure germanium detector for measuring radioactive elements in the ground, liquid scintillation counter for measuring 222 Rn gas concentration in water samples, Bubbler chamber and Locus cells for Rn concentration measurements (Emanation method) and Alfa guard detector for 226 Ra concentration measurements. Conclusions and Discussion: A total of 270 visitors are included in this study. Considering residual durations of the studied group in open and closed environment of bathrooms, hotel and inn rooms, obtained annual external effective dose is 75.4±8.7μSv and 138.3±11.8μSv for natives and travelers respectively. EEC coefficients has been used for calculating annual internal effective dose due to radon gas inhalation. Annual internal effective dose, in this path, is 0.9 and 2.1 mSv in open and closed environment for native and visitors respectively. Annual internal effective dose due to drinking water, is 0.43 and 0.09μSv for natives people and travelers, respectively. Measurements show that more than 90% of the received dose in the studied groups is due to radon gas inhalation. External and internal dose summation is 0.98 mSv for natives and 2.2 mSv for for

  3. Dry-boxes for manipulation of high-energy β emitters

    International Nuclear Information System (INIS)

    Boclet, K.; Laurent, H.

    1958-01-01

    Because of the thinners of latex or neoprene gloves and the high intensity of Bremsstrahlung radiation, manipulation of pure high-energy β - emitters is impossible in ordinary dry-boxes. There are many types of box equipped with heavy lead or steel protection, but their use for radioelements such as 32 P, 90 Sr, 90 Y is not justified. We have devised units known as 'tong boxes' which, while retaining much of the flexibility of operation found in dry-boxes, provide adequate protection. 1 curie of 32 P placed in the centre of the enclosure gives about 15 mR/ 8 h. at the part of the wall closest to the source. (author) [fr

  4. An MCNP model of glove boxes in a plutonium processing facility

    International Nuclear Information System (INIS)

    Dooley, D.E.; Kornreich, D.E.

    1998-01-01

    Nuclear material processing usually occurs simultaneously in several glove boxes whose primary purpose is to contain radioactive materials and prevent inhalation or ingestion of radioactive materials by workers. A room in the plutonium facility at Los Alamos National Laboratory has been slated for installation of a glove box for storing plutonium metal in various shapes during processing. This storage glove box will be located in a room containing other glove boxes used daily by workers processing plutonium parts. An MCNP model of the room and glove boxes has been constructed to estimate the neutron flux at various locations in the room for two different locations of the storage glove box and to determine the effect of placing polyethylene shielding around the storage glove box. A neutron dose survey of the room with sources dispersed as during normal production operations was used as a benchmark to compare the neutron dose equivalent rates calculated by the MCNP model

  5. Does previous use affect litter box appeal in multi-cat households?

    Science.gov (United States)

    Ellis, J J; McGowan, R T S; Martin, F

    2017-08-01

    It is commonly assumed that cats actively avoid eliminated materials (especially in multi-cat homes), suggesting regular litter box cleaning as the best defense against out-of-box elimination. The relationship between previous use and litter box appeal to familiar subsequent users is currently unknown. The purpose of this study was to investigate the relationship between previous litter box use and the identity of the previous user, type of elimination, odor, and presence of physical/visual obstructions in a multi-cat household scenario. Cats preferred a clean litter box to a dirty one, but the identity of the previous user had no impact on preferences. While the presence of odor from urine and/or feces did not impact litter box preferences, the presence of odorless faux-urine and/or feces did - with the presence of faux-feces being preferred over faux-urine. Results suggest neither malodor nor chemical communication play a role in litter box preferences, and instead emphasize the importance of regular removal of physical/visual obstructions as the key factor in promoting proper litter box use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  6. The heavy-ion physics programme with the ATLAS detector

    International Nuclear Information System (INIS)

    Rosselet, L

    2008-01-01

    The CERN LHC will collide lead ions at s√ = 5.5 TeV per nucleon pair and will provide crucial information about the formation of a quark-gluon plasma at the highest temperatures and densities ever created in the laboratory. We report on an updated evaluation of the ATLAS potential to study heavy-ion physics. The ATLAS detector will perform especially well for high pT phenomena even in the presence of the high-multiplicity soft background expected from lead-lead collisions, and most of the detector subsystems retain their nearly full capability. ATLAS will study a full range of observables which characterize the hot and dense medium formed in heavy-ion collisions. In addition to global measurements such as particle multiplicities and collective flow, heavy-quarkonia suppression, jet quenching and the modification of jets passing in the dense medium will be accessible. ATLAS will also study forward physics and ultraperipheral collisions using Zero Degree Calorimeters

  7. The Hot Cell Radioactive Waste Concept of Forschungszentrum Juelich

    International Nuclear Information System (INIS)

    Pott, G.; Halaszovich, St.

    1999-01-01

    During the last 30 years extensive scientific examinations on radioactive metals,ceramics and fuel elements have been carried out, so that a high volume of waste has resulted. Also from the dismantling of irradiated facilities metallics waste has o be handed. Prior for equipment repair the hot cell involved has to be decontaminated and a large amount of lower active waste is produced. The waste is collected for conditioning and storing. There are different categories as: low active liquid waste, low active burnable waste, fuel waste, low and high active metallic waste. For each waste category special transport container are used. For the volume reduction our Waste Department is equipped with special facilities e.g.: furnace for burning, drying, liquids evaporators, hydraulic press for pelletizing, decontamination box for the dismantling ad cleaning of components. After conditioning the waste will be stored on site or transported to final storage in a salt mine (ERAM) . Special documentation has to be done for the acceptance of this waste

  8. AstroBox: A novel detection system for very low-energy protons from β-delayed proton decay

    Energy Technology Data Exchange (ETDEWEB)

    Pollacco, E., E-mail: epollacco@cea.fr [IRFU, CEA Saclay, Gif-sur-Yvette (France); Trache, L. [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); National Institute of Physics and Nuclear Engineering, Bucharest-Magurele, RO-077125 (Romania); Simmons, E.; Spiridon, A.; McCleskey, M. [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); Roeder, B.T., E-mail: broeder@comp.tamu.edu [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); Saastamoinen, A.; Tribble, R.E. [Cyclotron Institute, Texas A and M University, College Station, TX 77843-3366 (United States); Pascovici, G. [National Institute of Physics and Nuclear Engineering, Bucharest-Magurele, RO-077125 (Romania); Kebbiri, M.; Mols, J.P.; Raillot, M. [IRFU, CEA Saclay, Gif-sur-Yvette (France)

    2013-09-21

    An instrument, AstroBox, has been developed to perform low energy proton spectroscopy from β-delayed proton emitters of interest to astrophysics studies. Energetic precursor nuclei are identified and stopped in the gas volume of the detector. The subsequent β or β-proton decay traces ionized paths in the gas. The ionization electrons are drifted in an electric field and are amplified with a Micro Pattern Gas Amplifier Detector (MPGAD). The system was tested in-beam using the β-delayed proton-emitter {sup 23}Al, which was produced with the p({sup 24}Mg,{sup 23}Al)2n reaction and separated with the Momentum Achromat Recoil Spectrometer (MARS) at the Cyclotron Institute at Texas A and M University. Off-beam proton spectra have essentially no β background down to ∼100keV and have a resolution of ∼15keV (fwhm) for proton-decay lines at E{sub p}=197 and 255 keV. Lines with βp-branching as low as 0.02% are observed. In addition, the device also gives good mass and charge resolution for energetic heavy ions measured in-beam.

  9. The DFBX cryogenic distribution boxes for the LHC straight sections

    International Nuclear Information System (INIS)

    Zbasnik, Jon P.; Corradi, Carol A.; Green, Michael A.; Kajiyama, Y.; Knolls, Michael J.; LaMantia, Roberto F.; Rasson, Joseph E.; Reavill, Dulie; Turner, William C.

    2002-01-01

    The DFBX distribution boxes are designed to connect the LHC cryogenic distribution system to the interaction region quadrupoles [1] and dipoles for the Large Hadron Collider (LHC). The DFBX distribution boxes also have the current leads for the superconducting interaction region magnets and the LHC interaction region correction coils. The DFBX boxes also connect the magnet and cryogenic instrumentation to the CERN data collection system. The DFBX boxes serve as the cryogenic circulation center and the nerve center for four of the LHC straight sections. This report describes primarily the cryogenic function of the DFBXs

  10. Lévy flights in a box

    International Nuclear Information System (INIS)

    Iomin, Alexander

    2015-01-01

    Highlights: •A quantum Lévy process in a box involves topological constraints in space. •The eigenvalue problem is formulated for the Lévy process in the box. •The path integral formalism with the Lévy measure is constructed. •The evolution operator is obtained in the path integral presentation. -- Abstract: It is shown that a quantum Lévy process in a box leads to a problem involving topological constraints in space, and its treatment in the framework of the path integral formalism with the Lévy measure is suggested. The eigenvalue problem for the infinite potential well is properly defined and solved. An analytical expression for the evolution operator is obtained in the path integral presentation, and the path integral takes the correct limit of the local quantum mechanics with topological constraints. An example of the Lévy process in oscillating walls is also considered in the adiabatic approximation

  11. Boxing injuries presenting to U.S. emergency departments, 1990-2008.

    Science.gov (United States)

    Potter, Matthew R; Snyder, Ashley J; Smith, Gary A

    2011-04-01

    Boxing injuries can have serious consequences. To examine the epidemiology of boxing injuries in the U.S. with attention to head injuries and children. National estimates of boxing injuries were calculated using data from the National Electronic Injury Surveillance System. Injury rates per 1000 participants for the year 2003 were calculated using boxing participation data. Data analysis was conducted in 2009-2010. An estimated 165,602 individuals (95% CI=134891, 196313) sustained boxing injuries that resulted in a visit to a U.S. hospital emergency department from 1990 through 2008. An average of 8716 (95% CI=7078, 10354) injuries occurred annually, and there was a statistically significant increase in the annual number of injuries during the 19-year study period (slope=610, pboxing injuries. The percentage of injuries that were concussions/closed head injuries in the group aged 12-17 years (8.9%) was similar to that in the group aged 18-24 years (8.1%) and the group aged 25-34 years (8.5%). These findings, based on a nationally representative sample, indicate that injuries related to boxing are increasing in number. Increased efforts are needed to prevent boxing injuries. Copyright © 2011 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  12. Coordinate reconstruction using box reconstruction and projection of X-ray photo

    International Nuclear Information System (INIS)

    Achmad Suntoro

    2011-01-01

    Some mathematical formula have been derived for a process of reconstruction to define the coordinate of any point relative to a pre set coordinate system. The process of reconstruction uses a reconstruction box in which each edge's length of the box is known, each top-bottom face and left-right face of the box having a cross marker, and the top face and the right face of the box as plane projections by X-ray source in perspective projection -system. Using the data of the two X-ray projection images, any point inside the reconstruction box, as long as its projection is recorded in the two photos, will be determined its coordinate relative to the midpoint of the reconstruction box as the central point coordinates. (author)

  13. Non-local boxes and their implementation in Minecraft

    Science.gov (United States)

    Simnacher, Timo Yannick

    PR-boxes are binary devices connecting two remote parties satisfying x AND y = a + b mod 2, where x and y denote the binary inputs and a and b are the respective outcomes without signaling. These devices are named after their inventors Sandu Popescu and Daniel Rohrlich and saturate the Clauser-Horne-Shimony-Holt (CHSH) inequality. This Bell-like inequality bounds the correlation that can exist between two remote, non-signaling, classical systems described by local hidden variable theories. Experiments have now convincingly shown that quantum entanglement cannot be explained by local hidden variable theories. Furthermore, the CHSH inequality provides a method to distinguish quantum systems from super-quantum correlations. The correlation between the outputs of the PR-box goes beyond any quantum entanglement. Though PR-boxes would have impressive consequences, as far as we know they are not physically realizable. However, by introducing PR-boxes to Minecraft as part of the redstone system, which simulates the electrical components for binary computing, we can experience the consequences of super-quantum correlations. For instance, Wim van Dam proved that two parties can use a sufficient number of PR-boxes to compute any Boolean function f(x,y) with only one bit of communication.

  14. Experience with the UHV box coater and the evaporation procedure for VUV reflective coatings on the HADES RICH mirror

    CERN Document Server

    Maier-Komor, P; Wieser, J; Ulrich, A

    1999-01-01

    An UHV box coater was set up for the deposition of highly reflective layers in the vacuum ultraviolet (VUV) wavelength range on large-area mirror substrates. The VUV mirrors are needed for the ring imaging Cherenkov (RICH) detector of the high-acceptance di-electron spectrometer (HADES). The complete dry vacuum system is described. The spatial deposition distribution from the evaporation sources was measured. The reflectivity of the Al mirror layer was optimized for the wavelength range of 145-210 nm by varying the thickness of the MgF sub 2 protective layer. The setup for measuring the reflectivity in the VUV range is described and reflectivity data are presented.

  15. Digital front-end electronics for COMPASS Muon-Wall 1 detector

    International Nuclear Information System (INIS)

    Alekseev, G.D.; Zhuravlev, N.I.; Maggiora, A.

    2005-01-01

    The digital front-end electronics for the COMPASS Muon-Wall 1 (CERN) detector is described. The digital card has been designed on the basis of the TDC chip F1. One card includes 6 F1 chips (192 channels), bus arbiter, DAC, power supply distribution, hot-link interface. The total number of the digital cards in the system is 44 housed in 5 euro-crates (6U), the total number of readout channels is 8448. The electronics has been designed by the Dzhelepov Laboratory of Nuclear Problems (JINR) and INFN (Torino, Italy) experts

  16. Closure of an analytical chemistry glove box in alpha laboratory

    International Nuclear Information System (INIS)

    Adelfang, P.; Aparicio, G.; Cassaniti, P.

    1990-01-01

    The works with plutonium are performed in gloves box, operated below atmospheric pressure, to protect the experimenters from this alpha-active material. After 12 years of continual processes, it was necessary the decommissioning of the chemistry glove box in our alpha-laboratory. A great deal of our attention was devoted to the working techniques because of extreme care needed to avoid activity release. The decommissioning includes the following main operations: a) Planning and documentation for the regulatory authority. b) Internal decontamination with surface cleaning and chelating agents. c) Measurement of the remainder internal radioactivity. d) Sealing of the glove ports and nozzles. e) Disconnection of the glove box from the exhaust duct. f) Design and construction of a container for the glove box. g) Transportation of the glove box from alpha-laboratory, to a transitory storage until its final disposal. The above mentioned operations are described in this paper including too: data of personal doses during the operations, characteristics and volumes of radioactive wastes and a description of the instrument used for the measurement of inside glove box activity. (Author) [es

  17. Confirmation test on confinement performance of improved glove box

    International Nuclear Information System (INIS)

    Miura, S.; Kanazawa, J.; Nakajima, M.; Sakuno, K.; Miyata, H.

    1995-01-01

    Glove boxes are used at nuclear facilities to confine radioactive materials by ensuring a high level of airtightness and negative internal pressure. The allowable rate of air leakage is 0.1% vol/hr or less at the pre-service inspection. The negative pressure value is normally maintained at about -30 mm H 2 O. Structural strength and confinement reliability of glove boxes during earthquake are major concerns, and most important glove boxes are designed to withstand seismic class A events is Japan. This paper describes vibration tests done to confirm that improve large-sized glove boxes maintain their confinement performance and structural strength even during earthquake and that the design analysis methods used are appropriate. (author). 1 ref., 6 figs., 3 tabs

  18. Pion in a box

    International Nuclear Information System (INIS)

    Bietenholz, W.; Rakow, P.E.L.; Schierholz, G.; Regensburg Univ.

    2010-02-01

    The residual mass of the pion in a finite spatial box at vanishing quark masses is computed with two flavors of dynamical clover fermions. The result is compared with predictions of chiral perturbation theory in the δ regime. (orig.)

  19. Studying radiative B decays with the Atlas detector

    International Nuclear Information System (INIS)

    Viret, S.

    2004-09-01

    This thesis is dedicated to the study of radiative B decays with the ATLAS detector at the LHC (large hadron collider). Radiative decays belong to the rare decays family. Rare decays transitions involve flavor changing neutral currents (for example b → sγ), which are forbidden at the lowest order in the Standard Model. Therefore these processes occur only at the next order, thus involving penguin or box diagrams, which are very sensitive to 'new physics' contributions. The main goal of our study is to show that it would be possible to develop an online selection strategy for radiative B decays with the ATLAS detector. To this end, we have studied the treatment of low energy photons by the ATLAS electromagnetic calorimeter (ECal). Our analysis shows that ATLAS ECal will be efficient with these particles. This property is extensively used in the next section, where a selection strategy for radiative B decays is proposed. Indeed, we look for a low energy region of interest in the ECal as soon as the level 1 of the trigger. Then, photon identification cuts are performed in this region at level 2. However, a large part of the proposed selection scheme is also based on the inner detector, particularly at level 2. The final results show that large amounts of signal events could be collected in only one year by ATLAS. A preliminary significance (S/√B) estimation is also presented. Encouraging results concerning the observability of exclusive radiative B decays are obtained. (author)

  20. Laparoscopic virtual reality simulator and box trainer in gynecology.

    Science.gov (United States)

    Akdemir, Ali; Sendağ, Fatih; Oztekin, Mehmet K

    2014-05-01

    To investigate whether a virtual reality simulator (LapSim) and traditional box trainer are effective tools for the acquisition of basic laparoscopic skills, and whether the LapSim is superior to the box trainer in surgical education. In a study at Ege University School of Medicine, Izmir, Turkey, between September 2008 and March 2013, 40 first- and second-year residents were randomized to train via the LapSim or box trainer for 4 weeks, and 20 senior residents were allocated to a control group. All 3 groups performed laparoscopic bilateral tubal ligation. Video records of each operation were assessed via the general rating scale of the Objective Structured Assessment of Laparoscopic Salpingectomy and by operation time in seconds. Compared with the control group, the LapSim and box trainer groups performed significantly better in total score (Peducation. Training with a virtual reality simulator or box trainer should be considered before actual laparoscopic procedures are carried out. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Assessment of integrated solar ultraviolet radiation by PM-355 detectors

    International Nuclear Information System (INIS)

    Abu-Jarad, F.; Al-Jarallah, M.I.; Elhadidy, M.A.; Shaahid, S.M.; Fazal-ur-Rehman

    2000-01-01

    detectors for environmental and personal solar UV dosimetry on a large scale in Saudi Arabia and similar hot and clear-sky countries

  2. Assessment of integrated solar ultraviolet radiation by PM-355 detectors

    Energy Technology Data Exchange (ETDEWEB)

    Abu-Jarad, F.; Al-Jarallah, M.I.; Elhadidy, M.A.; Shaahid, S.M.; Fazal-ur-Rehman

    2000-06-01

    detectors for environmental and personal solar UV dosimetry on a large scale in Saudi Arabia and similar hot and clear-sky countries.

  3. Glove box posting system

    International Nuclear Information System (INIS)

    McIntosh, A.E.

    1981-01-01

    A system for posting objects into closed containers, such as glove boxes, is described in which the bag used, preferably made of plastic, does not have to be fitted and sealed by the operator during each posting operation. (U.K.)

  4. Reassessment of the nonlocality of correlation boxes

    Energy Technology Data Exchange (ETDEWEB)

    Costa, A.P.; Parisio, Fernando, E-mail: parisio@df.ufpe.br

    2017-01-15

    Correlation boxes are hypothetical systems usually designed to produce the maximal algebraic violation of a Bell inequality, beyond the quantum bound and without superluminal signalling. The fact that these systems show stronger correlations than those presented by maximally entangled quantum states, as the spin singlet, has been regarded as a demonstration that the former are more nonlocal than the latter. By applying an alternative, consistent measure of nonlocality to a family of correlation boxes, we show that this conclusion is not necessarily true. Complementarily, we define a class of systems displaying subquantum correlations which, nevertheless, are more nonlocal than the singlet state, showing that the extent of the numeric violation of an inequality may have little to do with the degree of nonlocality, especially in the case of correlation boxes.

  5. Extended Krenciglowa-Kuo method and perturbation expansion of Q-box

    International Nuclear Information System (INIS)

    Shimizu, Genki; Otsuka, Takaharu; Takayanagi, Kazuo

    2015-01-01

    The Extended Krenciglowa-Kuo (EKK) method is a microscopic method to construct the energy-independent effective Hamiltonian H eff ; provided with an exact Q-box of the system, we can show which eigenstates are described by H eff given by the EKK method. In actual calculations, however, we can calculate the Q-box only up to a finite order in the perturbation theory. In this work, we examine the EKK method with the approximate Q-box, and show that the perturbative calculation of the Q-box does not harm the convergence properties of the EKK iterative method. (author)

  6. Acoustic response of superheated droplet detectors to neutrons

    International Nuclear Information System (INIS)

    Gao Size; Zhang Guiying; Ni Bangfa; Zhao Changjun; Zhang Huanqiao; Guan Yongjing; Chen Zhe; Xiao Caijin; Liu Chao; Liu Cunxiong

    2012-01-01

    The search for dark matter (DM) is a hot field nowadays, a number of innovative techniques have emerged. The superheated droplet technique is relatively mature; however, it is recently revitalized in a number of frontier fields including the search for DM. In this work, the acoustic response of Superheated Droplet Detectors (SDDs) to neutrons was studied by using a 252 Cf neutron source, SDDs developed by the China Institute of Atomic Energy, a sound sensor, a sound card and a PC. Sound signals were filtered. The characteristics of FFT spectra, power spectra and time constants were used to determine the authenticity of the bubbles analyzed.

  7. VBSM: VCC-Based Black Box Service Model with Enhanced Data Integrity

    OpenAIRE

    Kang, Won; Lee, Jae; Park, Jong

    2014-01-01

    Recently, intelligent transport systems have been applied to vehicle cloud environments. Such technology is especially useful for the systematic management of road traffic. Moreover, automobiles are increasingly equipped with a black box for accident prevention and preservation of evidence. Vehicle black boxes have become mandatory because black box images and voice data have served as forensic evidence in courts. However, the data from black boxes can be forged or modified by man-in-the-midd...

  8. Bi-phase CO{sub 2} cooling of the CBM STS detector

    Energy Technology Data Exchange (ETDEWEB)

    Lavrik, Evgeny [Physikalisches Institut der Universitaet Tuebingen (Germany); Collaboration: CBM-Collaboration

    2016-07-01

    The Compressed Baryonic Matter (CBM) experiment aims to study the properties of nuclear matter at high net-baryon densities. The Silicon Tracking System (STS) is the key detector to reconstruct charged particle tracks created in heavy-ion interactions. The foreseen interaction rate of up to 10 MHz requires radiation hard detectors as well as efficient cooling of the silicon sensors. To avoid thermal runaway the system must be kept at -5 C or below all the time. This is rather challenging because the overall thermal load in the 2 m{sup 3} STS enclosure is up to 40 kW. Because of these requirements liquid CO{sub 2} is used as a cooling agent as it is superior in terms of volumetric heat transfer coefficient compared to other agents. This contribution shows the thermal simulations and measurement results of the STS front-end electronic boxes as well as an overview of 1 kW TRACI-XL cooling plant developed at GSI and its use to perform thermal measurements of a fully heat loaded STS quarter station.

  9. Comfort-box controls individual level of comfort. Domotica home network for indoor climate management; Comfort-box regelt individueel comfort-niveau. Domotica-huisnetwerk voor beheer binnenklimaat

    Energy Technology Data Exchange (ETDEWEB)

    Kamphuis, I.G; Warmer, C.J.; Bakker, E.J. [ECN Duurzame Energie in de Gebouwde Omgeving DEGO, Petten (Netherlands)

    2005-03-01

    The Comfort-Box (or C-Box) project is an automatic and continuous control system for energy efficient and cost-effective thermal comfort in houses. In this article detailed information is given of the design and performance of the C-Box. [Dutch] De huidige regelsystemen voor het binnenklimaat in woningen zijn voor verbetering vatbaar. Met het Comfort-boxconcept is een regeling ontwikkeld die automatisch en continu het individuele comfortniveau regelt in woningen, waarbij afwegingen worden gemaakt tussen kosten en comfort. De Comfort-box blijkt in staat te zijn het binnencomfort op energie- en kostenefficiente wijze te beheren.

  10. Using Origami Boxes to Explore Concepts of Geometry and Calculus

    Science.gov (United States)

    Wares, Arsalan

    2011-01-01

    The purpose of this classroom note is to provide an example of how a simple origami box can be used to explore important concepts of geometry and calculus. This article describes how an origami box can be folded, then it goes on to describe how its volume and surface area can be calculated. Finally, it describes how the box could be folded to…

  11. Dream Box Learning. What Works Clearinghouse Intervention Report

    Science.gov (United States)

    What Works Clearinghouse, 2013

    2013-01-01

    "DreamBox Learning" is a supplemental online mathematics program that provides adaptive instruction for students in grades K-5 and focuses on number and operations, place value, and number sense. The What Works Clearinghouse (WWC) identified one study of "DreamBox Learning" that both falls within the scope of the Elementary…

  12. Decorated-box-diagram contributions to Bhabha scattering. Pt. 1

    International Nuclear Information System (INIS)

    Faeldt, G.; Osland, P.

    1994-01-01

    We evaluate, in the light-energy limit, s>>vertical stroke tvertical stroke >>m 2 >>λ 2 , the sum of amplitudes corresponding to a class of Feynman diagrams describing two-loop virtual photonic corrections to Bhabha scattering. The diagrams considered are box and crossed-box diagrams with an extra photon decorating one of the fermion lines. The mathematical method employed is that of Mellin transforms. In the eikonal approximation, this sum of two-loop amplitudes has previously been evaluated, and found to be equal to the sum of the box and crossed-box amplitudes, multiplied by the electric form factor of the electron. We obtain a similar factorization, but with the form factor replaced by another expression involving the logarithms log(λ 2 /m 2 ) and log(λ 2 /vertical stroke tvertical stroke ). (orig.)

  13. Radiation detectors

    International Nuclear Information System (INIS)

    2013-01-01

    This sixth chapter presents the operational principles of the radiation detectors; detection using photographic emulsions; thermoluminescent detectors; gas detectors; scintillation detectors; liquid scintillation detectors; detectors using semiconductor materials; calibration of detectors; Bragg-Gray theory; measurement chain and uncertainties associated to measurements

  14. VBSM: VCC-Based Black Box Service Model with Enhanced Data Integrity

    Directory of Open Access Journals (Sweden)

    Won Min Kang

    2014-10-01

    Full Text Available Recently, intelligent transport systems have been applied to vehicle cloud environments. Such technology is especially useful for the systematic management of road traffic. Moreover, automobiles are increasingly equipped with a black box for accident prevention and preservation of evidence. Vehicle black boxes have become mandatory because black box images and voice data have served as forensic evidence in courts. However, the data from black boxes can be forged or modified by man-in-the-middle (MITM attacks and message hijacking. In this paper, we propose a vehicle cloud computing-based black box service model that can provide integrity for black box data through digital signatures in vehicle cloud computing (VCC environments. Our proposed model protects against MITM attacks and message hijacking using only a hash value and digital signature. Moreover, a mirroring technique (RAID 1 provides backup and recovery to protect the data from a traffic accident.

  15. Hot-rolled Process of Multilayered Composite Metal Plate

    Directory of Open Access Journals (Sweden)

    YU Wei

    2017-02-01

    Full Text Available For multi-layer plate, it is a difficult problem to increase product yield rate and improve bonding interface quality. A high yield hot-rolled method of multilayered plate was proposed. The raw strips and plate were fixed by argon arc welding. The combined billet was put into a metal box and vacuum pumped, and then heated and rolled by multi passes at the temperature of 1000-1200℃. The 67 layered plate with the thickness of 2.5mm was successfully produced. The interfacial microstructures and diffusion behavior were investigated and analyzed by optical microscopy and scan electronic microscopy. The tensile and shear strength were tested,and the shear fractures were analyzed. The results show that the multilayered plate yield rate is more than 90% by two steps billet combination method and rolling process optimization. The good bonding interface quality is obtained, the shear strength of multilayered plate reaches 241 MPa. Nickel interlayer between 9Cr18 and 1Cr17 can not only prevent the diffusion of carbon, but also improve the microstructure characteristics.

  16. Mystery Box Marvels

    Science.gov (United States)

    Santos, Joel; Centurio, Tina

    2012-01-01

    What happens in the first week of school could very well set the stage for the rest of the school year. Setting high standards for science activities based in inquiry can start on the first day of science class and develop as the year unfolds. With the use of simple, readily available, inexpensive materials, an efficient mystery box lesson can be…

  17. The Classroom Animal: Box Turtles.

    Science.gov (United States)

    Kramer, David C.

    1986-01-01

    Provides basic information on the anatomy, physiology, behaviors, and distribution patterns of the box turtle. Offers suggestions for the turtle's care and maintenance in a classroom environment. (ML)

  18. A novel method to design S-box based on chaotic map and genetic algorithm

    International Nuclear Information System (INIS)

    Wang, Yong; Wong, Kwok-Wo; Li, Changbing; Li, Yang

    2012-01-01

    The substitution box (S-box) is an important component in block encryption algorithms. In this Letter, the problem of constructing S-box is transformed to a Traveling Salesman Problem and a method for designing S-box based on chaos and genetic algorithm is proposed. Since the proposed method makes full use of the traits of chaotic map and evolution process, stronger S-box is obtained. The results of performance test show that the presented S-box has good cryptographic properties, which justify that the proposed algorithm is effective in generating strong S-boxes. -- Highlights: ► The problem of constructing S-box is transformed to a Traveling Salesman Problem. ► We present a new method for designing S-box based on chaos and genetic algorithm. ► The proposed algorithm is effective in generating strong S-boxes.

  19. A novel method to design S-box based on chaotic map and genetic algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yong, E-mail: wangyong_cqupt@163.com [State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400044 (China); Key Laboratory of Electronic Commerce and Logistics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China); Wong, Kwok-Wo [Department of Electronic Engineering, City University of Hong Kong, 83 Tat Chee Avenue, Kowloon Tong (Hong Kong); Li, Changbing [Key Laboratory of Electronic Commerce and Logistics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China); Li, Yang [Department of Automatic Control and Systems Engineering, The University of Sheffield, Mapping Street, S1 3DJ (United Kingdom)

    2012-01-30

    The substitution box (S-box) is an important component in block encryption algorithms. In this Letter, the problem of constructing S-box is transformed to a Traveling Salesman Problem and a method for designing S-box based on chaos and genetic algorithm is proposed. Since the proposed method makes full use of the traits of chaotic map and evolution process, stronger S-box is obtained. The results of performance test show that the presented S-box has good cryptographic properties, which justify that the proposed algorithm is effective in generating strong S-boxes. -- Highlights: ► The problem of constructing S-box is transformed to a Traveling Salesman Problem. ► We present a new method for designing S-box based on chaos and genetic algorithm. ► The proposed algorithm is effective in generating strong S-boxes.

  20. Removal of the nonconformities in the drug boxes packaging industry

    Directory of Open Access Journals (Sweden)

    Bălan Emilia

    2017-01-01

    Full Text Available The paper presents the specific quality aspects of cardboard drug boxes (folding boxes used as packaging in pharmaceutical industry. The types of defects and nonconformities that occur during offset printing and finishing of the packaging products are being identified and analyzed, such as: differences in color printing, scratches on the printed sheets, cracks during creasing, unparalleled gluing in respect to the closing flaps, ungluing, successive drug boxes stick to each other. The paper also focuses on aspects regarding the nonconformities removal of the drug boxes by establishing a control plan and preventive and corrective methods applicable in different technological stages of the production flow. Monitoring and analyzing activities for quality improvement of the drug boxes, in accordance with the quality specifications required by customers were performed for 20 months on a production line with Heidelberg machines. Nonconformities considered in this paper are also encountered in advertising printing.

  1. Immunohistochemical evidence for multiple photosystems in box jellyfish

    DEFF Research Database (Denmark)

    Ekström, Peter; Garm, Anders Lydik; Pålsson, Jonas

    2008-01-01

    data demonstrate that the lens eyes of box jellyfish utilize a single opsin and are thus color-blind, and that there is probably a different photopigment in the pigment cup eyes. The results support our hypothesis that the lens eyes and the pigment cup eyes of box jellyfish are involved in different...

  2. 77 FR 74513 - Folding Gift Boxes From China

    Science.gov (United States)

    2012-12-14

    ... From China Determination On the basis of the record \\1\\ developed in the subject five-year review, the... boxes from China would be likely to lead to continuation or recurrence of material injury to an industry... Publication 4365 (November 2012), entitled Folding Gift Boxes from China: Investigation No. 731-TA-921 (Second...

  3. A System for Cooling inside a Glove Box

    Science.gov (United States)

    Sanz, Martial

    2010-01-01

    An easy, efficient, reliable, and low-cost method of constructing a cooling system using a simple circulating pump is described. The system is employed in conjunction with an inert atmosphere glove box to achieve the synthesis of air- and moisture-sensitive compounds inside the glove box at controlled, low temperatures without contaminating the…

  4. [Boxing-related cranial injury in children: a case report].

    Science.gov (United States)

    Timsit, S; Rougeau, T; Grevent, D; Chéron, G

    2012-11-01

    No pediatric recommendations exist in France on the exercise of boxing by children and adolescents despite the risk of traumatic injury, sometimes serious. We report the case of a 15-year-old boy who participated in amateur boxing and had a subdural hematoma. Brain injuries and concussions are frequent and multiple. Severity is not always correlated with the intensity of the blows. There are age-related features. Several international medical organizations oppose boxing for children and adolescents. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  5. Box and block test in Beninese adults.

    Science.gov (United States)

    Natta, Ditouah Didier Niama; Alagnidé, Etienne; Kpadonou, Toussaint Godonou; Detrembleur, Christine; Lejeune, Thierry M; Stoquart, Gaëtan G

    2015-11-01

    To determine the Box and Block Test norm in a sub-Saharan population and to compare these data with published norms for North American adults. A total of 692 healthy Beninese people, age range 20-85 years, were recruited. These subjects were asked to perform the Box and Block Test with both hands. Box and Block Test scores (mean and standard deviation (SD)) for women and men were, respectively, 81.3 (15.4) and 79 (16.6) for the dominant hand and 73.2 (13.7) and 72 (14.8) for the non-dominant hand. Mean Box and Block Test scores ranged from 89.1 (12.7) for people under the age of 25 years to 55.23 (10.5) for people over the age of 74 years. Manual dexterity was better for women than men, for dominant hand than non-dominant hand, and for younger subjects. In comparison with published results for US subjects, Beninese subjects had better dexterity below the age of 50 years in both sexes for the right hand and worse dexterity over 64 years of age in both sexes for the right hand. Developing and validating outcome scales in Africa will help to improve functional assessment of African populations in clinical practice and research.

  6. Safety evaluation for packaging CPC metal boxes

    International Nuclear Information System (INIS)

    Romano, T.

    1995-01-01

    This Safety Evaluation for Packaging (SEP) provides authorization for the use of Container Products Corporation (CPC) metal boxes, as described in this document, for the interarea shipment of radioactive contaminated equipment and debris for storage in the Central Waste Complex (CWC) or T Plant located in the 200 West Area. Authorization is granted until November 30, 1995. The CPC boxes included in this SEP were originally procured as US Department of Transportation (DOT) Specification 7A Type A boxes. A review of the documentation provided by the manufacturer revealed the documentation did not adequately demonstrate compliance to the 4 ft drop test requirement of 49 CFR 173.465(c). Preparation of a SEP is necessary to document the equivalent safety of the onsite shipment in lieu of meeting DOT packaging requirements until adequate documentation is received. The equivalent safety of the shipment is based on the fact that the radioactive contents consist of contaminated equipment and debris which are not dispersible. Each piece is wrapped in two layers of no less than 4 mil plastic prior to being placed in the box which has an additional 10 mil liner. Pointed objects and sharp edges are padded to prevent puncture of the plastic liner and wrapping

  7. Double Length Regressions for Testing the Box-Cox Difference Transformation.

    OpenAIRE

    Park, Timothy

    1991-01-01

    The Box-Cox difference transformation is used to determine the appropriate specification for estimation of hedge ratios and a new double length regression form of the Lagrange multiplier test is presented for the difference transformation. The Box-Cox difference transformation allows the testing of the first difference model and the returns model as special cases of the Box-Cox difference transformation. Copyright 1991 by MIT Press.

  8. FPGA-based GEM detector signal acquisition for SXR spectroscopy system

    Science.gov (United States)

    Wojenski, A.; Pozniak, K. T.; Kasprowicz, G.; Kolasinski, P.; Krawczyk, R.; Zabolotny, W.; Chernyshova, M.; Czarski, T.; Malinowski, K.

    2016-11-01

    The presented work is related to the Gas Electron Multiplier (GEM) detector soft X-ray spectroscopy system for tokamak applications. The used GEM detector has one-dimensional, 128 channel readout structure. The channels are connected to the radiation-hard electronics with configurable analog stage and fast ADCs, supporting speeds of 125 MSPS for each channel. The digitalized data is sent directly to the FPGAs using fast serial links. The preprocessing algorithms are implemented in the FPGAs, with the data buffering made in the on-board 2Gb DDR3 memory chips. After the algorithmic stage, the data is sent to the Intel Xeon-based PC for further postprocessing using PCI-Express link Gen 2. For connection of multiple FPGAs, PCI-Express switch 8-to-1 was designed. The whole system can support up to 2048 analog channels. The scope of the work is an FPGA-based implementation of the recorder of the raw signal from GEM detector. Since the system will work in a very challenging environment (neutron radiation, intense electro-magnetic fields), the registered signals from the GEM detector can be corrupted. In the case of the very intense hot plasma radiation (e.g. laser generated plasma), the registered signals can overlap. Therefore, it is valuable to register the raw signals from the GEM detector with high number of events during soft X-ray radiation. The signal analysis will have the direct impact on the implementation of photon energy computation algorithms. As the result, the system will produce energy spectra and topological distribution of soft X-ray radiation. The advanced software was developed in order to perform complex system startup and monitoring of hardware units. Using the array of two one-dimensional GEM detectors it will be possible to perform tomographic reconstruction of plasma impurities radiation in the SXR region.

  9. Study on structural integrity in box structures

    International Nuclear Information System (INIS)

    Asano, Masayuki; Ueta, Masahiro; Kanaoka, Tadashi; Ikeuchi, Toshiaki; Kodama, Tetsuhiro.

    1991-01-01

    This study was carried out to give an experimental foundation to the structural integrity of a box structure. Crack growth tests were performed on the reduced scale models, simulating typical portions of the box structure, in air at room temperature. The results show that the amount of crack growth is too small to injure the structural integrity of the models for the postulated loading cycle, and make clear the effective structure against crack growth. (author)

  10. Random Young diagrams in a Rectangular Box

    DEFF Research Database (Denmark)

    Beltoft, Dan; Boutillier, Cédric; Enriquez, Nathanaël

    We exhibit the limit shape of random Young diagrams having a distribution proportional to the exponential of their area, and confined in a rectangular box. The Ornstein-Uhlenbeck bridge arises from the fluctuations around the limit shape.......We exhibit the limit shape of random Young diagrams having a distribution proportional to the exponential of their area, and confined in a rectangular box. The Ornstein-Uhlenbeck bridge arises from the fluctuations around the limit shape....

  11. Faster Black-Box Algorithms Through Higher Arity Operators

    DEFF Research Database (Denmark)

    Doerr, Benjamin; Johannsen, Daniel; Kötzing, Timo

    2011-01-01

    We extend the work of Lehre and Witt (GECCO 2010) on the unbiased black-box model by considering higher arity variation operators. In particular, we show that already for binary operators the black-box complexity of LeadingOnes drops from (n2) for unary operators to O(n log n). For OneMax, the (n...

  12. On the channel box for the fuel bundle of BWR

    International Nuclear Information System (INIS)

    Yokoyama, Hiroomi; Yamamoto, Takeo

    1976-01-01

    Channel boxes play the important roles of making coolant flow uniform and protecting fuel rods as the component of fuel assemblies for BWRs. About ten years ago, the domestic production of channel boxes was first investigated, and now, the original technology has been developed, and the channel boxes sufficiently satisfying the required quality can be produced. The actual experience by being charged in reactors has also been accumulated. At present, the supply capacity is almost sufficient to meet the domestic demand, and the future increase of demand can be dealt with promptly. The channel boxes are made of Zircaloy-4 plates which are favorable in view of neutron absorption, and are the boxes with 138 mm hollow square section, 2 mm thickness, and 4240 mm length. Two channels were welded together and made into a box. In order to eliminate the residual stress caused during the manufacture, high temperature heating with an electric furnace was adopted. The measurement of dimensions and the inspection of appearance of the channel boxes after irradiation proved that they were rather superior to imported ones. The production processes, the system for the quality guarantee, and the quality control in the Kobe Steel Ltd. are explained. The test and inspection are carried out at the time of accepting outside products, before starting the production, after the completion of longitudinal welding and after the completion of production. (Kako, I.)

  13. The aerogel threshold Cherenkov detector for the high momentum spectrometer in Hall C at Jefferson lab

    International Nuclear Information System (INIS)

    Razmik Asaturyan; Rolf Ent; Howard Fenker; David Gaskell; Garth Huber; Mark Jones; David Mack; Hamlet Mkrtchyan; Bert Metzger; Nadia Novikoff; Vardan Tadevosyan; William Vulcan; Stephen Wood

    2004-01-01

    We describe a new aerogel threshold Cherenkov detector installed in the HMS spectrometer in Hall C at Jefferson Lab. The Hall C experimental program in 2003 required an improved particle identification system for better identification of π/K/p, which was achieved by installing an additional threshold Cherenkov counter. Two types of aerogel with n = 1.03 and n = 1.015 allow one to reach ∼10 -3 proton and 10 -2 kaon rejection in the 1-5 GeV/c momentum range with pion detection efficiency better than 99% (97%). The detector response shows no significant position dependence due to a diffuse light collection technique. The diffusion box was equipped with 16 Photonis XP4572 PMT's. The mean number of photoelectrons in saturation was ∼16 and ∼8, respectively. Moderate particle identification is feasible near threshold

  14. Measurements of Low Frequency Noise of Infrared Photo-Detectors with Transimpedance Detection System

    Directory of Open Access Journals (Sweden)

    Ciura Łukasz

    2014-08-01

    Full Text Available The paper presents the method and results of low-frequency noise measurements of modern mid-wavelength infrared photodetectors. A type-II InAs/GaSb superlattice based detector with nBn barrier architecture is compared with a high operating temperature (HOT heterojunction HgCdTe detector. All experiments were made in the range 1 Hz - 10 kHz at various temperatures by using a transimpedance detection system, which is examined in detail. The power spectral density of the nBn’s dark current noise includes Lorentzians with different time constants while the HgCdTe photodiode has more uniform 1/f - shaped spectra. For small bias, the low-frequency noise power spectra of both devices were found to scale linearly with bias voltage squared and were connected with the fluctuations of the leakage resistance. Leakage resistance noise defines the lower noise limit of a photodetector. Other dark current components give raise to the increase of low-frequency noise above this limit. For the same voltage biasing devices, the absolute noise power densities at 1 Hz in nBn are 1 to 2 orders of magnitude lower than in a MCT HgCdTe detector. In spite of this, low-frequency performance of the HgCdTe detector at ~ 230K is still better than that of InAs/GaSb superlattice nBn detector.

  15. Acute subdural hematoma because of boxing.

    Science.gov (United States)

    Kushi, Hidehiko; Saito, Takeshi; Sakagami, Yuichiro; Ohtsuki, Jyoji; Tanjoh, Katsuhisa

    2009-02-01

    To identify factors determining the clinical characteristics and prognosis of acute subdural hematoma (ASDH) arising from boxing injuries by comparing with ASDH due to any nonboxing cause. Two groups were selected for this study: 10 patients with ASDH because of boxing injuries and 26 patients with nonboxer ASDH. All of the patients underwent neurologic examination by neurosurgeons. Primary resuscitation and stabilization as well as operative therapy were performed to all patients according to the European Brain Injury Consortium Guidelines. Two groups were compared in terms of age, the Glasgow Coma Scale at admission, neurologic findings, craniogram and brain computed tomography scan findings, operative findings, and prognosis. As potential prognostic indicators for boxers, the time interval until surgery, the Glasgow Outcome Scale, hematoma thickness, midline shift, and the site of bleeding were analyzed. The characteristics of patients because of boxing injuries are that patients were younger, had lucid interval, and had no cerebral contusion or contralateral brain injury. There was no significant difference in initial Glasgow Coma Scale, hematoma thickness, midline shift, and their prognosis. The most peculiar clinical presentation of boxers' ASDH was that all bleedings were limited from "bridging veins" or "cortical veins." The prognosis of boxers was most closely correlated with the site of bleeding (r2 = 0.81; p = 0.0001) and the midline shift (r2 = 0.67; p = 0.007). Our study shows that ASDH because of boxing is characterized by bleeding from bridging or cortical veins, and that the site of bleeding is a significant determinant of their prognosis.

  16. Parametric Design and Rapid Prototyping of Installation Box for Vehicle Terminal PCB

    Directory of Open Access Journals (Sweden)

    Wang Xingxing

    2016-01-01

    Full Text Available Installation box for vehicle terminal PCB (Printed Circuit Board was took as research object, which is encountered in the process of project developing. Vehicle terminal PCB in actual development process was set as an example, point cloud data were acquired by three coordinate measuring method; Imageware software was used to reconstruct the vehicle terminal PCB model, basic size parameters of vehicle terminal PCB can be got and then design parameters of installation box for vehicle terminal PCB can be determined. Design of the installation box for vehicle terminal PCB was completed based on Solidworks software, then 3D modeling and 2D drawing of installation box for vehicle terminal PCB was gained. Up Plus 2 rapid prototype machine was used to manufacture installation box for vehicle terminal PCB rapidly based on 3D printing technology, then prototype of installation box for vehicle terminal PCB was obtained. It is of certain engineering significant for single (small amount manufacturing of installation box for general PCB.

  17. X-ray spectroscopy of warm and hot electron components in the CAPRICE source plasma at EIS testbench at GSI.

    Science.gov (United States)

    Mascali, D; Celona, L; Maimone, F; Maeder, J; Castro, G; Romano, F P; Musumarra, A; Altana, C; Caliri, C; Torrisi, G; Neri, L; Gammino, S; Tinschert, K; Spaedtke, K P; Rossbach, J; Lang, R; Ciavola, G

    2014-02-01

    An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source - operating at GSI, Darmstadt - has been carried out. Two different detectors (a SDD - Silicon Drift Detector and a HpGe - hyper-pure Germanium detector) have been used to characterize the warm (2-30 keV) and hot (30-500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract the plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.

  18. Ionization detector

    International Nuclear Information System (INIS)

    Steele, D.S.

    1987-01-01

    An ionization detector having an array of detectors has, for example, grounding pads positioned in the spaces between some detectors (data detectors) and other detectors (reference detectors). The grounding pads are kept at zero electric potential, i.e. grounded. The grounding serves to drain away electrons and thereby prevent an unwanted accumulation of charge in the spaces, and cause the electric field lines to be more perpendicular to the detectors in regions near the grounding pads. Alternatively, no empty space is provided there being additional, grounded, detectors provided between the data and reference detectors. (author)

  19. Box-Cox transformation of firm size data in statistical analysis

    Science.gov (United States)

    Chen, Ting Ting; Takaishi, Tetsuya

    2014-03-01

    Firm size data usually do not show the normality that is often assumed in statistical analysis such as regression analysis. In this study we focus on two firm size data: the number of employees and sale. Those data deviate considerably from a normal distribution. To improve the normality of those data we transform them by the Box-Cox transformation with appropriate parameters. The Box-Cox transformation parameters are determined so that the transformed data best show the kurtosis of a normal distribution. It is found that the two firm size data transformed by the Box-Cox transformation show strong linearity. This indicates that the number of employees and sale have the similar property as a firm size indicator. The Box-Cox parameters obtained for the firm size data are found to be very close to zero. In this case the Box-Cox transformations are approximately a log-transformation. This suggests that the firm size data we used are approximately log-normal distributions.

  20. Box-Cox transformation of firm size data in statistical analysis

    International Nuclear Information System (INIS)

    Chen, Ting Ting; Takaishi, Tetsuya

    2014-01-01

    Firm size data usually do not show the normality that is often assumed in statistical analysis such as regression analysis. In this study we focus on two firm size data: the number of employees and sale. Those data deviate considerably from a normal distribution. To improve the normality of those data we transform them by the Box-Cox transformation with appropriate parameters. The Box-Cox transformation parameters are determined so that the transformed data best show the kurtosis of a normal distribution. It is found that the two firm size data transformed by the Box-Cox transformation show strong linearity. This indicates that the number of employees and sale have the similar property as a firm size indicator. The Box-Cox parameters obtained for the firm size data are found to be very close to zero. In this case the Box-Cox transformations are approximately a log-transformation. This suggests that the firm size data we used are approximately log-normal distributions

  1. Tworty Box to Improve the Equipment Logistics of Container Lines

    Directory of Open Access Journals (Sweden)

    Ulrich Malchow

    2016-07-01

    Full Text Available A major share of all empty container positioning (deadheading is resulting from imbalances with regard to container sizes (20ft/40ft. In order to reduce the shipments of 'containerised air' a new type of container has been developed by the author: The Tworty Boxes can either be used as a standard 20ft or in coupled condition as a 40ft container. The outside appearance resembles any standard 20ft container. However the Tworty Box is unique in that it has an additional door at the front side that opens to the inside. This door can be fixed to the ceiling and by using of bonding elements another Tworty Box can be joined up, thereby creating the full 40ft inside space. Operated as a single 20ft box the additional door remains locked, access is only through the existing standard door. Tworty Boxes do not require any additional components and fulfil all ISO and CSC requirements.

  2. Comparative analysis of profitability of honey production using traditional and box hives.

    Science.gov (United States)

    Al-Ghamdi, Ahmed A; Adgaba, Nuru; Herab, Ahmed H; Ansari, Mohammad J

    2017-07-01

    Information on the profitability and productivity of box hives is important to encourage beekeepers to adopt the technology. However, comparative analysis of profitability and productivity of box and traditional hives is not adequately available. The study was carried out on 182 beekeepers using cross sectional survey and employing a random sampling technique. The data were analyzed using descriptive statistics, analysis of variance (ANOVA), the Cobb-Douglas (CD) production function and partial budgeting. The CD production function revealed that supplementary bee feeds, labor and medication were statistically significant for both box and traditional hives. Generally, labor for bee management, supplementary feeding, and medication led to productivity differences of approximately 42.83%, 7.52%, and 5.34%, respectively, between box and traditional hives. The study indicated that productivity of box hives were 72% higher than traditional hives. The average net incomes of beekeepers using box and traditional hives were 33,699.7 SR/annum and 16,461.4 SR/annum respectively. The incremental net benefit of box hives over traditional hives was nearly double. Our study results clearly showed the importance of adoption of box hives for better productivity of the beekeeping subsector.

  3. Comparative analysis of profitability of honey production using traditional and box hives

    Directory of Open Access Journals (Sweden)

    Ahmed A. Al-Ghamdi

    2017-07-01

    Full Text Available Information on the profitability and productivity of box hives is important to encourage beekeepers to adopt the technology. However, comparative analysis of profitability and productivity of box and traditional hives is not adequately available. The study was carried out on 182 beekeepers using cross sectional survey and employing a random sampling technique. The data were analyzed using descriptive statistics, analysis of variance (ANOVA, the Cobb-Douglas (CD production function and partial budgeting. The CD production function revealed that supplementary bee feeds, labor and medication were statistically significant for both box and traditional hives. Generally, labor for bee management, supplementary feeding, and medication led to productivity differences of approximately 42.83%, 7.52%, and 5.34%, respectively, between box and traditional hives. The study indicated that productivity of box hives were 72% higher than traditional hives. The average net incomes of beekeepers using box and traditional hives were 33,699.7 SR/annum and 16,461.4 SR/annum respectively. The incremental net benefit of box hives over traditional hives was nearly double. Our study results clearly showed the importance of adoption of box hives for better productivity of the beekeeping subsector.

  4. A Novel Image Encryption Based on Algebraic S-box and Arnold Transform

    Science.gov (United States)

    Farwa, Shabieh; Muhammad, Nazeer; Shah, Tariq; Ahmad, Sohail

    2017-09-01

    Recent study shows that substitution box (S-box) only cannot be reliably used in image encryption techniques. We, in this paper, propose a novel and secure image encryption scheme that utilizes the combined effect of an algebraic substitution box along with the scrambling effect of the Arnold transform. The underlying algorithm involves the application of S-box, which is the most imperative source to create confusion and diffusion in the data. The speciality of the proposed algorithm lies, firstly, in the high sensitivity of our S-box to the choice of the initial conditions which makes this S-box stronger than the chaos-based S-boxes as it saves computational labour by deploying a comparatively simple and direct approach based on the algebraic structure of the multiplicative cyclic group of the Galois field. Secondly the proposed method becomes more secure by considering a combination of S-box with certain number of iterations of the Arnold transform. The strength of the S-box is examined in terms of various performance indices such as nonlinearity, strict avalanche criterion, bit independence criterion, linear and differential approximation probabilities etc. We prove through the most significant techniques used for the statistical analyses of the encrypted image that our image encryption algorithm satisfies all the necessary criteria to be usefully and reliably implemented in image encryption applications.

  5. Natural Interaction Based Online Military Boxing Learning System

    Science.gov (United States)

    Yang, Chenglei; Wang, Lu; Sun, Bing; Yin, Xu; Wang, Xiaoting; Liu, Li; Lu, Lin

    2013-01-01

    Military boxing, a kind of Chinese martial arts, is widespread and health beneficial. In this paper, the authors introduce a military boxing learning system realized by 3D motion capture, Web3D and 3D interactive technologies. The interactions with the system are natural and intuitive. Users can observe and learn the details of each action of the…

  6. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    International Nuclear Information System (INIS)

    Croft, Stephen; Martancik, David; Young, Brian; Chard MJ, Patrick; Estop J, Robert; Sheila Melton; Arnone, Gaetano J.

    2003-01-01

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nuclide and isotopic compositions Assay of high density matrices (both high-Z and high moderator contents)Correction for radioactive material physical form - such as self shielding or multiplication effects due to large accumulations of radioactive materials.Calibration with a minimal set of reference standards and representative matrices.THis document summarizes the conceptual design parameters of the IBIS and indicates areas key to the success of the project where development is to be centered. The work presented here is a collaborative effort between scientific staff within Canberra and within the NIS-6 group at LANL

  7. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    Energy Technology Data Exchange (ETDEWEB)

    DR. Stephen Croft; Mr. David Martancik; Dr. Brian Young; Dr. Patrick MJ Chard; Dr. Robert J Estop; Sheila Melton; Gaetano J. Arnone

    2003-01-13

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nuclide and isotopic compositions Assay of high density matrices (both high-Z and high moderator contents)Correction for radioactive material physical form - such as self shielding or multiplication effects due to large accumulations of radioactive materials.Calibration with a minimal set of reference standards and representative matrices.THis document summarizes the conceptual design parameters of the IBIS and indicates areas key to the success of the project where development is to be centered. The work presented here is a collaborative effort between scientific staff within Canberra and within the NIS-6 group at LANL.

  8. Gamma-ray boxes from axion-mediated dark matter

    International Nuclear Information System (INIS)

    Ibarra, Alejandro; Gehler, Sergio López; Pato, Miguel; Lee, Hyun Min; Park, Wan-Il

    2013-01-01

    We compute the gamma-ray output of axion-mediated dark matter and derive the corresponding constraints set by recent data. In such scenarios the dark matter candidate is a Dirac fermion that pair-annihilates into axions and/or scalars. Provided that the axion decays (at least partly) into photons, these models naturally give rise to a box-shaped gamma-ray spectrum that may present two distinct phenomenological behaviours: a narrow box, resembling a line at half the dark matter mass, or a wide box, spanning an extensive energy range up to the dark matter mass. Remarkably, we find that in both cases a sizable gamma-ray flux is predicted for a thermal relic without fine-tuning the model parameters nor invoking boost factors. This large output is in line with recent Fermi-LAT observations towards the galactic centre region and is on the verge of being excluded. We then make use of the Fermi-LAT and H.E.S.S. data to derive robust, model-independent upper limits on the dark matter annihilation cross section for the narrow and wide box scenarios. H.E.S.S. constraints, in particular, turn out to match the ones from Fermi-LAT at hundreds of GeV and extend to multi-TeV masses. Future Čerenkov telescopes will likely probe gamma-ray boxes from thermal dark matter relics in the whole multi-TeV range, a region hardly accessible to direct detection, collider searches and other indirect detection strategies

  9. Mortality resulting from head injury in professional boxing.

    Science.gov (United States)

    Baird, Lissa C; Newman, C Benjamin; Volk, Hunter; Svinth, Joseph R; Conklin, Jordan; Levy, Michael L

    2010-11-01

    The majority of boxing-related fatalities result from traumatic brain injury. Biomechanical forces in boxing result in rotational acceleration with resultant subdural hematoma and diffuse axonal injury. Given the inherent risk and the ongoing criticism boxing has received, we evaluated mortalities associated with professional boxing. We used the Velaquez Fatality Collection of boxing injuries and supplementary sources to analyze mortality from 1950 to 2007. Variables evaluated included age at time of death, association with knockout or other outcome of match, rounds fought, weight class, location of fight, and location of pretermial event. There were 339 mortalities between 1950 and 2007 (mean age, 24 ± 3.8 years); 64% were associated with knockout and 15% with technical knockout. A higher percentage occurred in the lower weight classes. The preterminal event occurred in the ring (61%), in the locker room (17%), and outside the arena (22%), We evaluated for significant changes after 1983 when championship bouts were reduced from 15 to 12 rounds. There was a significant decline in mortality after 1983. We found no significant variables to support that this decline is related to a reduction in rounds. Rather, we hypothesize the decline to be the result of a reduction in exposure to repetitive head trauma (shorter careers and fewer fights), along with increased medical oversight and stricter safety regulations. Increased efforts should be made to improve medical supervisions of boxers. Mandatory central nervous system imaging after a knockout could lead to a significant reduction in associated mortality.

  10. Fatigue Testing of Maglev-Hybrid Box Beam

    Science.gov (United States)

    2009-03-02

    04142009 3. DATES COVERED: (From - To) 23052006-14092008 4. TITLE AND SUBTITLE Fatigue Testing of Maglev -Hybrid Box Beam 5a. CONTRACT NUMBER NA...was previously built under collaboration between Maglev Inc. and Lehigh University. The girder was instrumented with strain gages and LVDT’s to monitor...report March 2,2009 Contract N00014-06-1-0872 Project: Fatigue Testing of Maglev -Hybrid Box Beam Prepared by Dr. J.L. Grenestedt and Dr. R. Sause

  11. Meal box schemes as a convenient way to avoid convenience food?

    DEFF Research Database (Denmark)

    Hertz, Frej; Halkier, Bente

    2017-01-01

    to categorize meal box schemes as a new form of convenience food called convenient food. In addition, results suggest that meal box schemes reduce leftovers from dinner. Meal boxes also influence dinner related activities such as planning ahead in time and grocery shopping, which require less physical......The term convenience food is subject to diversification, lack of clarity and moral ambiguity. In this paper we address these issues and critically discuss convenience food by using empirical findings from a Danish study that deals with practitioners' uses of meal box schemes. The methodological...

  12. Evaluation of decontamination during dismantling of plutonium-contaminated glove boxes

    International Nuclear Information System (INIS)

    Kinugasa, Manabu; Taguchi, Seigi; Ohzeki, Satoru; Inoue, Yoshiaki; Kashima, Sadamitsu

    1981-01-01

    The dismantling work of plutonium-contaminated glove boxes was carried out. These glove boxes had been used for the R and D of plutonium-uranium mixed oxide fuel for 15 years. The work was carried out in a pressure-controlled greenhouse, and the contamination of air in the greenhouse was monitored continuously. In order to reduce the contamination of air during dismantling, the decontamination and fixation of loose contaminants on the surfaces of glove boxes were very important. The correlation between decontamination and the contamination of air regarding dismantling is reported in this paper. The surface contamination density of the glove boxes was measured utilizing the smear method before and after the decontamination, and the decontamination effects were estimated. The contamination of air during dismantling was continuously measured with a plutonium dust monitor. It was found that loose contamination exponentially decreased by the decontamination process. When the so-called wet glove boxes, which contained wet recovery and waste disposal apparatus, were dismantled, the contamination of air did not exceed 500 (MPC) a. However, the contamination of air exceeded 500 (MPC) a several times in the present work of dismantling the so-called dry glove boxes which had been used for the fabrication of plutonium-uranium mixed oxide pellets. (Kato, T.)

  13. Evidence for multiple major histocompatibility class II X-box binding proteins.

    OpenAIRE

    Celada, A; Maki, R

    1989-01-01

    The X box is a loosely conserved DNA sequence that is located upstream of all major histocompatibility class II genes and is one of the cis-acting regulatory elements. Despite the similarity between all X-box sequences, each promoter-proximal X box in the mouse appears to bind a separate nuclear factor.

  14. Preparation, characterization, and optimization of altretamine-loaded solid lipid nanoparticles using Box-Behnken design and response surface methodology.

    Science.gov (United States)

    Gidwani, Bina; Vyas, Amber

    2016-01-01

    The objective of the present study was to prepare solid lipid nanoparticles (SLNs) of altretamine (ALT) by the hot homogenization and ultrasonication method. The study was conducted using the Box-Behnken design (BBD), with a 3(3) design and a total of 17 experimental runs, performed in combination with response surface methodology (RSM). The SLNs were evaluated for mean particle size, entrapment efficiency, and drug-loading. The optimized formulation, with a desirability factor of 0.92, was selected and characterized. In vitro release studies showed a biphasic release pattern from the SLNs for up to 24 h. The results of % EE (93.21 ± 1.5), %DL (1.15 ± 0.6), and mean diameter of (100.6 ± 2.1) nm, were very close to the predicted values.

  15. Weak interactions in hot nucleon matter

    International Nuclear Information System (INIS)

    Cowell, S.; Pandharipande, V.R.

    2006-01-01

    The reaction rates for electron capture, neutrino absorption, and neutrino scattering in hot asymmetric nuclear matter are calculated with two-body effective interactions and one-body effective weak operators obtained from realistic models of nuclear forces by use of correlated basis theory. The infinite system is modeled in a box with periodic boundary conditions, and the one-quasiparticle quasi-hole response functions are calculated with a large microcanonical sample and the Tamm-Dancoff approximation. Results for matter at a temperature of 10 MeV, proton fraction 0.4, and densities ρ=(1/2),1,(3/2)ρ 0 , where ρ 0 is the equilibrium density of symmetric nuclear matter, are presented to illustrate the method. In general, the strength of the response is shifted to higher-energy transfers when compared with that of a noninteracting Fermi gas. The shift in the response and the weakness of effective operators as compared with the bare operators significantly reduce the cross sections for electron capture and neutrino scattering by factors of ∼2.5-3.5. In contrast, the symmetry energy enhances the neutrino absorption reaction rate relative to the Fermi gas. However, this reaction rate is still quite small because of Pauli blocking

  16. Boxing: medical care in and out of the ring.

    Science.gov (United States)

    Gambrell, Robert C

    2007-10-01

    Boxing may well be the oldest sport known to mankind and probably the most controversial. Injuries are common in boxing, occurring most often to the head, neck, face, and hands. Brain injury, both acute and chronic, is the major risk for potential catastrophe. Medical care for the boxer extends beyond the competition in the boxing ring; the ringside physician is responsible for protecting both boxers and must make quick decisions about their continued participation based upon a limited examination. A thorough knowledge of the rules and regulations of boxing is necessary for the ringside physician to effectively care for the athlete. In spite of the perceived brutality associated with the sport, most injuries are minor, although serious injuries and deaths do occur, most commonly due to brain injury. Given the potential for catastrophic injury, the ringside physician must be prepared and equipped to care for the boxer.

  17. Restoration and Reexamination of Apollo Lunar Dust Detector Data from Original Telemetry Files

    Science.gov (United States)

    McBride, M. J.; Williams, David R.; Hills, H. Kent

    2012-01-01

    We are recovering the original telemetry (Figure I) from the Apollo Dust, Thermal, Radiation Environment Monitor (DTREM) experiment, more commonly known as the Dust Detector, and producing full time resolution (54 second) data sets for release through the Planetary Data System (PDS). The primary objective of the experiment was to evaluate the effect of dust deposition, temperature, and radiation damage on solar cells on the lunar surface. The monitor was a small box consisting of three solar cells and thermistors mounted on the ALSEP (Apollo Lunar Surface Experiments Package) central station. The Dust Detector was carried on Apollo's 11, 12, 14 and 15. The Apollo 11 DTREM was powered by solar cells and only operated for a few months as planned. The Apollo 12, 14, and 15 detectors operated for 5 to 7 years, returning data every 54 seconds, consisting of voltage outputs from the three solar cells and temperatures measured by the three thermistors. The telemetry was received at ground stations and held on the Apollo Housekeeping (known as "Word 33") tapes. made available to the National Space Science Data Center (NSSDC) by Yosio Nakamura (University of Texas Institute for Geophysics). We have converted selected parts of the telemetry into uncalibrated and calibrated output voltages and temperatures.

  18. ESF SOUTH PORTAL BOX-CUT/HIGHWALL STABILITY ANALYSIS (SCPB:N/A)

    International Nuclear Information System (INIS)

    Saeed Bonabian

    1996-01-01

    The main purpose and objective of this analysis is to design a Box-Cut at the ESF South Portal to accommodate the Tunnel Boring Machine's (TBM) exit at the conclusion of the ESF Main Loop construction. The stability of the Highwall and the sidewalls at the Box-Cut are assessed using analytical methods by numerical modeling techniques. A ground reinforcement system for the South Ramp Box-Cut slopes will be recommended. This report summarizes the results of the analyses and provides the details of the recommended ground reinforcement system for the Box-Cut slopes at the South Portal. The reinforcement design details are then incorporated into design output documents for implementation in the field. Method of excavation for the Box-Cut is also discussed and a recommendation is provided in this analysis

  19. Study of Microstructure of the Al-Fe Alloys After Hot Rolling Deformation

    Science.gov (United States)

    Jabłońska, Magdalena Barbara; Rodak, Kinga; Bednarczyk, Iwona

    The aim of the paper is a microstructure analysis of alloys from the Al-Fe system after hot rolling tests, conducted by using a scanning transmission electron microscopy STEM and scanning electron microscope equipped with EBSD detector. Hot rolling was carried out at Technical University of Ostrava, Faculty of Metallurgy and Material Engineering, Institute of Modelling and Control of Forming Processes. The samples were heated to a temperature of 1200°C. The EBSD and STEM techniques have been applied in order to determine the influence of chemical composition and deformation parameters on structural changes. The microstructure analysis has included parameters such us: grain/sub-grain size, area fraction of grains/subgrains, misorientation angles, grains/subgrains shape aspect ratio and dislocations structure. The research structure techniques in scanning-transmission electron microscopy revealed numerous FeAl28 alloy phase separations of secondary nucleating sites favoured energetically, which are the boundary of grains/subgrains and dislocations. These changes in the structure of the test results have been confirmed by EBSD, which revealed the presence of grains/subgrains misorientation angle boundaries above 15°.

  20. Nine optical black-box experiments for lower-secondary students

    Science.gov (United States)

    Rode, Henning; Friege, Gunnar

    2017-05-01

    In this paper a sequence of nine, easy to manufacture optical black-box experiments with increasing levels of difficulty, and supportive frameworks for physics classes are introduced. They have been evaluated in a lower-secondary school at the end of optics lessons. A black-box is a kind of experimental task where the inner structure is not visible to the experimenter. Using mirrors, beam-splitters, and blockers in a black-box to manipulate the light beam’s direction through this specific experiment, students are instructed to vary input and observe the output of light to get an idea of the possible inner structure. The presented sequence of black-box experiments requires a basic knowledge of the linear propagation of light and is suitable for beginner physics. Furthermore a framework for concrete implementation to physics classes is given, which covers suitable structure of class, examples for helpful worksheets, and authentic students’ solutions. The difficulty of the specific black-box experiments is given by the students’ success within observing input-output correlation and conclusion of an inner structure. The experiments’ implementation to physics classes may cover elaboration, practice, and aspects of the nature of science even in a beginner’s class. Evaluation has been conducted with students of young age (11-12 years old), however they are suitable for older students also. Although dealing with a time extensive sequence of experiments, students showed a high level of motivation throughout. Overall, implementing this sequence of black-box experiments is seen as valuable and helpful for physics classes.

  1. Fast parallel ring recognition algorithm in the RICH detector of the CBM experiment at FAIR

    International Nuclear Information System (INIS)

    Lebedev, S.

    2011-01-01

    The Compressed Baryonic Matter (CBM)experiment at the future FAIR facility at Darmstadt will measure dileptons emitted from the hot and dense phase in heavy ion collisions. In case of an electron measurement, a high purity of identified electrons is required in order to suppress the background. Electron identification in CBM will be performed by a Ring Imaging Cherenkov (RICH) detector and Transition Radiation Detector (TRD). Very fast data reconstruction is extremely important for CBM because of the huge amount of data which has to be handled. In this contribution, a parallelized ring recognition algorithm is presented. Modern CPUs have two features, which enable parallel programming. First, the SSE technology allows using the SIMD execution model. Second, multicore CPUs enable the use of multithreading. Both features have been implemented in the ring reconstruction of the RICH detector. A considerable speedup factor from 357 to 2.5 ms/event has been achieved including preceding code optimization for Intel Xeon X5550 processors at 2.67 GHz

  2. Hot Surface Ignition

    OpenAIRE

    Tursyn, Yerbatyr; Goyal, Vikrant; Benhidjeb-Carayon, Alicia; Simmons, Richard; Meyer, Scott; Gore, Jay P.

    2015-01-01

    Undesirable hot surface ignition of flammable liquids is one of the hazards in ground and air transportation vehicles, which primarily occurs in the engine compartment. In order to evaluate the safety and sustainability of candidate replacement fuels with respect to hot surface ignition, a baseline low lead fuel (Avgas 100 LL) and four experimental unleaded aviation fuels recommended for reciprocating aviation engines were considered. In addition, hot surface ignition properties of the gas tu...

  3. Qualification of box HEPA filters for nuclear applications

    International Nuclear Information System (INIS)

    Bergman, W.; Larsen, G.; Wilson, K.; Rainer, F.

    1995-03-01

    We have successfully completed qualification tests on high efficiency particulate air (HEPA) filters that are encapsulated within a box and manufactured by American Air Filters. The qualification tests are required by the American Society of Mechanical Engineers Standard ASME N509 and the U.S. Military Standard MIL-F-51068 for HEPA filters to be used in nuclear applications. The qualification tests specify minimum filter efficiencies following exposure to heated air, overpressure, and rough handling. Prior to this study, no box HEPA filters from any manufacturer had been qualified despite their wide-spread use in Department of Energy (DOE) facilities. Box HEPA filters are not addressed in any of the existing HEPA standards and only briefly discussed in the Nuclear Air Cleaning Handbook

  4. Predicting a future lifetime through Box-Cox transformation.

    Science.gov (United States)

    Yang, Z

    1999-09-01

    In predicting a future lifetime based on a sample of past lifetimes, the Box-Cox transformation method provides a simple and unified procedure that is shown in this article to meet or often outperform the corresponding frequentist solution in terms of coverage probability and average length of prediction intervals. Kullback-Leibler information and second-order asymptotic expansion are used to justify the Box-Cox procedure. Extensive Monte Carlo simulations are also performed to evaluate the small sample behavior of the procedure. Certain popular lifetime distributions, such as Weibull, inverse Gaussian and Birnbaum-Saunders are served as illustrative examples. One important advantage of the Box-Cox procedure lies in its easy extension to linear model predictions where the exact frequentist solutions are often not available.

  5. Disaggregating Hot Water Use and Predicting Hot Water Waste in Five Test Homes

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, H.; Wade, J.

    2014-04-01

    While it is important to make the equipment (or 'plant') in a residential hot water system more efficient, the hot water distribution system also affects overall system performance and energy use. Energy wasted in heating water that is not used is estimated to be on the order of 10 to 30 percent of total domestic hot water (DHW) energy use. This field monitoring project installed temperature sensors on the distribution piping (on trunks and near fixtures) and programmed a data logger to collect data at 5 second intervals whenever there was a hot water draw. This data was used to assign hot water draws to specific end uses in the home as well as to determine the portion of each hot water that was deemed useful (i.e., above a temperature threshold at the fixture). Five houses near Syracuse NY were monitored. Overall, the procedures to assign water draws to each end use were able to successfully assign about 50% of the water draws, but these assigned draws accounted for about 95% of the total hot water use in each home. The amount of hot water deemed as useful ranged from low of 75% at one house to a high of 91% in another. At three of the houses, new water heaters and distribution improvements were implemented during the monitoring period and the impact of these improvements on hot water use and delivery efficiency were evaluated.

  6. Disaggregating Hot Water Use and Predicting Hot Water Waste in Five Test Homes

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, Hugh [ARIES Collaborative, New York, NY (United States); Wade, Jeremy [ARIES Collaborative, New York, NY (United States)

    2014-04-01

    While it is important to make the equipment (or "plant") in a residential hot water system more efficient, the hot water distribution system also affects overall system performance and energy use. Energy wasted in heating water that is not used is estimated to be on the order of 10%-30% of total domestic hot water (DHW) energy use. This field monitoring project installed temperature sensors on the distribution piping (on trunks and near fixtures) in five houses near Syracuse, NY, and programmed a data logger to collect data at 5 second intervals whenever there was a hot water draw. This data was used to assign hot water draws to specific end uses in the home as well as to determine the portion of each hot water that was deemed useful (i.e., above a temperature threshold at the fixture). Overall, the procedures to assign water draws to each end use were able to successfully assign about 50% of the water draws, but these assigned draws accounted for about 95% of the total hot water use in each home. The amount of hot water deemed as useful ranged from low of 75% at one house to a high of 91% in another. At three of the houses, new water heaters and distribution improvements were implemented during the monitoring period and the impact of these improvements on hot water use and delivery efficiency were evaluated.

  7. ALICE upgrades its powerful eyes

    CERN Multimedia

    Yuri Kharlov, ALICE Collaboration

    2013-01-01

    The ALICE Photon Spectrometer (PHOS) is a high-resolution photon detector that measures the photons coming out of the extremely hot plasma created in the lead-lead collisions at the LHC. Taking advantage of the long accelerator shut-down, the ALICE teams are now repairing and upgrading the existing modules and getting ready to install the brand-new module in time for the next run. The upgraded PHOS detector will be faster and more stable with wider acceptance and improved photon identification.   PHOS crystal matrix during repair. The key feature and the main complexity of the ALICE PHOS detector is that it operates at a temperature of -25°C, which makes it the second-coldest equipment element at the LHC after the cryogenic superconducting magnets. Since 2009 when it was installed, the PHOS detector, with its cold and warm volumes, has been immersed in airtight boxes to avoid condensation in the cold volumes. The 10,752 lead tungstate crystals of the PHOS were completely insulated fr...

  8. Security of the AES with a Secret S-Box

    DEFF Research Database (Denmark)

    Tiessen, Tyge; Knudsen, Lars Ramkilde; Kölbl, Stefan

    2015-01-01

    How does the security of the AES change when the S-box is replaced by a secret S-box, about which the adversary has no knowledge? Would it be safe to reduce the number of encryption rounds? In this paper, we demonstrate attacks based on integral cryptanalysis which allow to recover both the secret...... key and the secret S-box for respectively four, five, and six rounds of the AES. Despite the significantly larger amount of secret information which an adversary needs to recover, the attacks are very efficient with time/data complexities of 217/216, 238/240 and 290/264, respectively. Another...

  9. Relationship between hot spot residues and ligand binding hot spots in protein-protein interfaces.

    Science.gov (United States)

    Zerbe, Brandon S; Hall, David R; Vajda, Sandor; Whitty, Adrian; Kozakov, Dima

    2012-08-27

    In the context of protein-protein interactions, the term "hot spot" refers to a residue or cluster of residues that makes a major contribution to the binding free energy, as determined by alanine scanning mutagenesis. In contrast, in pharmaceutical research, a hot spot is a site on a target protein that has high propensity for ligand binding and hence is potentially important for drug discovery. Here we examine the relationship between these two hot spot concepts by comparing alanine scanning data for a set of 15 proteins with results from mapping the protein surfaces for sites that can bind fragment-sized small molecules. We find the two types of hot spots are largely complementary; the residues protruding into hot spot regions identified by computational mapping or experimental fragment screening are almost always themselves hot spot residues as defined by alanine scanning experiments. Conversely, a residue that is found by alanine scanning to contribute little to binding rarely interacts with hot spot regions on the partner protein identified by fragment mapping. In spite of the strong correlation between the two hot spot concepts, they fundamentally differ, however. In particular, while identification of a hot spot by alanine scanning establishes the potential to generate substantial interaction energy with a binding partner, there are additional topological requirements to be a hot spot for small molecule binding. Hence, only a minority of hot spots identified by alanine scanning represent sites that are potentially useful for small inhibitor binding, and it is this subset that is identified by experimental or computational fragment screening.

  10. Design and performance of the focusing DIRC detector

    Energy Technology Data Exchange (ETDEWEB)

    Dey, B. [University of California, Riverside, CA 92521 (United States); Borsato, M.; Arnaud, N. [Laboratoire de l' Accélérateur Linéaire, Centre Scientifique d' Orsay, F-91898 Orsay Cedex (France); Leith, D.W.G.S.; Nishimura, K. [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States); Roberts, D.A. [University of Maryland, College Park, MD 20742, USA. (United States); Ratcliff, B.N. [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States); Varner, G. [University of Hawaii, Honolulu, HI 96822, USA. (United States); Va' vra, J., E-mail: jjv@slac.stanford.edu [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States)

    2015-03-01

    We present the final results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a full-scale prototype of the particle identification system for the SuperB experiment [1], and comprises 1/12 of the SuperB barrel azimuthal coverage, with partial photodetector and electronics implementation. The prototype was tested in the SLAC Cosmic Ray Telescope which provided 3D tracking of cosmic muons with an angular resolution of ~1.5 mrad, a position resolution of 4–5 mm, a start time resolution of 70 ps, and muon tracks above ~2 GeV tagged using an iron range stack. The fused silica focusing photon camera was coupled to a full-size BaBar DIRC bar box and was read out, over part of the full coverage, by 12 Hamamatsu H8500 multi-anode photomultipliers (MaPMTs) providing 768 pixels. We used waveform digitizing electronics to read out the MaPMTs. We give a detailed description of our data analysis methods and point out limitations on the present performance. We present results that demonstrate some basic performance characteristics of this design, including (a) single photon Cherenkov angle resolutions with and without chromatic corrections, (b) signal-to-noise (S/N) ratio between the Cherenkov peak and background, which primarily consists of ambiguities of the possible photon paths from emission along the track to a given pixel, (c) dTOP=TOP{sub measured} – TOP{sub expected} resolutions (with TOP being the photon Time-of-Propagation in fused silica), and (d) performance of the detector in the presence of high-rate backgrounds.

  11. Signals of Bose Einstein condensation and Fermi quenching in the decay of hot nuclear systems

    Energy Technology Data Exchange (ETDEWEB)

    Marini, P., E-mail: marini@cenbg.in2p3.fr [Grand Accélérateur National d' Ions Lourds, Bd. Henri Becquerel, BP 55027, 14076 Caen (France); Zheng, H. [Cyclotron Institute, Texas A& M University, College Station, TX-77843 (United States); Laboratori Nazionali del Sud, INFN, via Santa Sofia, 62, 95123 Catania (Italy); Boisjoli, M. [Grand Accélérateur National d' Ions Lourds, Bd. Henri Becquerel, BP 55027, 14076 Caen (France); Laboratoire de Physique Nucléaire, Université Laval, Québec, G1V 0A6 (Canada); Verde, G. [Institut de Physique Nucléaire, CNRS-IN2P3, Univ. Paris-Sud, Université Paris-Saclay, 91406 Orsay Cedex (France); INFN – Sezione di Catania, via Santa Sofia, 64, 95123 Catania (Italy); Chbihi, A. [Grand Accélérateur National d' Ions Lourds, Bd. Henri Becquerel, BP 55027, 14076 Caen (France); Napolitani, P.; Ademard, G. [Institut de Physique Nucléaire, CNRS-IN2P3, Univ. Paris-Sud, Université Paris-Saclay, 91406 Orsay Cedex (France); Augey, L. [Laboratoire de Physique Corpusculaire, ENSICAEN, Université de Caen Basse Normandie, CNRS/IN2P3, F-14050 Caen Cedex (France); Bhattacharya, C. [Variable Energy Cyclotron Center, Kolkata (India); Borderie, B. [Institut de Physique Nucléaire, CNRS-IN2P3, Univ. Paris-Sud, Université Paris-Saclay, 91406 Orsay Cedex (France); Bougault, R. [Laboratoire de Physique Corpusculaire, ENSICAEN, Université de Caen Basse Normandie, CNRS/IN2P3, F-14050 Caen Cedex (France); and others

    2016-05-10

    We report on first experimental observations of nuclear fermionic and bosonic components displaying different behaviours in the decay of hot Ca projectile-like sources produced in mid-peripheral collisions at sub-Fermi energies. The experimental setup, constituted by the coupling of the INDRA 4π detector array to the forward angle VAMOS magnetic spectrometer, allowed to reconstruct the mass, charge and excitation energy of the decaying hot projectile-like sources. By means of quantum-fluctuation analysis techniques, temperatures and local partial densities of bosons and fermions could be correlated to the excitation energy of the reconstructed system. The results are consistent with the production of dilute mixed systems of bosons and fermions, where bosons experience higher phase-space and energy density as compared to the surrounding fermionic gas. Our findings recall phenomena observed in the study of Bose condensates and Fermi gases in atomic traps despite the different scales.

  12. Black-boxing and cause-effect power

    Science.gov (United States)

    Albantakis, Larissa; Tononi, Giulio

    2018-01-01

    Reductionism assumes that causation in the physical world occurs at the micro level, excluding the emergence of macro-level causation. We challenge this reductionist assumption by employing a principled, well-defined measure of intrinsic cause-effect power–integrated information (Φ), and showing that, according to this measure, it is possible for a macro level to “beat” the micro level. Simple systems were evaluated for Φ across different spatial and temporal scales by systematically considering all possible black boxes. These are macro elements that consist of one or more micro elements over one or more micro updates. Cause-effect power was evaluated based on the inputs and outputs of the black boxes, ignoring the internal micro elements that support their input-output function. We show how black-box elements can have more common inputs and outputs than the corresponding micro elements, revealing the emergence of high-order mechanisms and joint constraints that are not apparent at the micro level. As a consequence, a macro, black-box system can have higher Φ than its micro constituents by having more mechanisms (higher composition) that are more interconnected (higher integration). We also show that, for a given micro system, one can identify local maxima of Φ across several spatiotemporal scales. The framework is demonstrated on a simple biological system, the Boolean network model of the fission-yeast cell-cycle, for which we identify stable local maxima during the course of its simulated biological function. These local maxima correspond to macro levels of organization at which emergent cause-effect properties of physical systems come into focus, and provide a natural vantage point for scientific inquiries. PMID:29684020

  13. Dry boxes and inert atmosphere techniques

    International Nuclear Information System (INIS)

    Bartak, D.E.

    1987-01-01

    Practitioners need to conduct experiments with molten salts in an inert atmosphere owing to the chemical reactivity of these media. Most fused salt solvent systems show reactivity to water and/or oxygen, which results in significant chemical changes in the properties of these solvents. Although several studies on the nature of an oxygen/oxide electrode in this melt have been reported, the reactions have not been fully understood because of apparent water contamination in many cases. Nitrate melt systems are also hygroscopic; for example, the LiNO 3 -KNO 3 eutectic (177 0 C) absorbs water to at least 0.2% by weight. The result is that the electrochemistry of heavier, electropositive metal ions has been significantly altered. In addition, trace amounts of water have been shown to significantly affect the oxygen-oxide redox chemistry in NaNO 3 -KNO 3 melts (250 0 C). The haloaluminates, which include AlCl 3 -NaCl (175 0 C), as well as AlCl 3 -organic salt binaries are particularly sensitive to the presence of both oxygen and moisture. Oxygen is a strong oxidant in the fused hydroxide systems with formation of superoxide ion from either oxide or water. This chapter describes general, inert atmosphere techniques which can be used by the molten salt experimentalist. Because of the limitations of volatility, vacuum manipulations are not considered. Rather, the use of glove boxes, glove bags, and inert bench-top techniques are discussed. The areas covered are: glove box and bag equipment, operation and maintenance of glove boxes and glove bags, and common operations conducted inside glove boxes

  14. Black-boxing and cause-effect power.

    Directory of Open Access Journals (Sweden)

    William Marshall

    2018-04-01

    Full Text Available Reductionism assumes that causation in the physical world occurs at the micro level, excluding the emergence of macro-level causation. We challenge this reductionist assumption by employing a principled, well-defined measure of intrinsic cause-effect power-integrated information (Φ, and showing that, according to this measure, it is possible for a macro level to "beat" the micro level. Simple systems were evaluated for Φ across different spatial and temporal scales by systematically considering all possible black boxes. These are macro elements that consist of one or more micro elements over one or more micro updates. Cause-effect power was evaluated based on the inputs and outputs of the black boxes, ignoring the internal micro elements that support their input-output function. We show how black-box elements can have more common inputs and outputs than the corresponding micro elements, revealing the emergence of high-order mechanisms and joint constraints that are not apparent at the micro level. As a consequence, a macro, black-box system can have higher Φ than its micro constituents by having more mechanisms (higher composition that are more interconnected (higher integration. We also show that, for a given micro system, one can identify local maxima of Φ across several spatiotemporal scales. The framework is demonstrated on a simple biological system, the Boolean network model of the fission-yeast cell-cycle, for which we identify stable local maxima during the course of its simulated biological function. These local maxima correspond to macro levels of organization at which emergent cause-effect properties of physical systems come into focus, and provide a natural vantage point for scientific inquiries.

  15. Teaching with Box Tops.

    Science.gov (United States)

    Raiser, Lynne; D'Zamko, Mary Elizabeth

    1984-01-01

    Using environmental materials (such as the phone book and placemats from fast food restaurants) can be a motivating way to teach learning disabled students skills and concepts, as shown in an approach to reading, math, science and nutrition, and social studies instruction using a JELL-O brand gelatin box. (CL)

  16. Cover gas box for handling sodium

    International Nuclear Information System (INIS)

    Kuenstler, K.; Betzl, K.

    1978-01-01

    An inert atmosphere box has been developed to work with sodium experimentally and analytically. The volumen of the box is 0.6 m 3 . A blower mounted inside the work chamber constantly circulates the argon from the work chamber through a gas purification system (nickel-catalyst 6525 and molecular sieve 4A). The flow rate is 450 l/h. The box is equipped with neoprene gloves. The glove ports can be closed with interior flanges. The work chamber is constantly kept to a low superpressure of 25 mm water gange. In a bypass the oxygen concentration is measured with the OXYLYT-electrolyte cell and the water vapour concentration with the KEIDEL-electrolytic hygrometer. During long-term operation oxygen levels of 35 vpm and water vapour levels of 50 vpm can be hold even when the gloves are not covered. By means of putting a vessel with liquid sodium in the work chamber oxygen levels of 8 vpm and water vapour levels of 20 vpm can be attained for short times. The inert atmosphere purity can be improved by means of increasing the gas flow rate. (author)

  17. Investigation of the influence of hybrid layers on the life time of hot forging dies

    Directory of Open Access Journals (Sweden)

    S. Legutko

    2013-04-01

    Full Text Available The paper deals with the issues related in the process of drop forging with special attention paid to the durability of forging tools. It presents the results of industrial investigation of the influence of hybrid layers on hot forging dies. The effectiveness of hybrid layers type nitrided layer/PVD coating applied for extending the life of forging tools whose working surfaces are exposed to such complex exploitation conditions as, among others, cyclically varying high thermal and mechanical loads, as well as intensive abrasion at raised temperature. The examination has been performed on a set of forging tools made of Unimax steel and intended for forging steel rings of gear box synchronizer in the factory FAS in Swarzedz (Poland.

  18. Energy flux of hot atoms

    International Nuclear Information System (INIS)

    Wotzak, G.P.; Kostin, M.D.

    1976-01-01

    The process in which hot atoms collide with thermal atoms of a gas, transfer kinetic energy to them, and produce additional hot atoms is investigated. A stochastic method is used to obtain numerical results for the spatial and time dependent energy flux of hot atoms in a gas. The results indicate that in hot atom systems a front followed by an intense energy flux of hot atoms may develop

  19. Hard x-ray measurements of the hot-electron rings in EBT-S

    International Nuclear Information System (INIS)

    Hillis, D.L.

    1982-06-01

    A thorough understanding of the hot electron rings in ELMO Bumpy Torus-Scale (EBT-S) is essential to the bumpy torus concept of plasma production, since the rings provide bulk plasma stability. The hot electrons are produced via electron cyclotron resonant heating using a 28-GHz cw gyrotron, which has operated up to power levels of 200 kW. The parameters of the energetic electron rings are studied via hard x-ray measurement techniques and with diamagnetic pickup coils. The hard x-ray measurements have used collimated NaI(Tl) detectors to determine the electron temperature T/sub e/ and electron density n/sub e/ for the hot electron annulus. Typical values of T/sub e/ are 400 to 500 keV and of n/sub e/ 2 to 5 x 10 11 cm -3 . The total stored energy of a single energetic electron ring as measured by diamagnetic pickup loops approaches approx. 40 J and is in good agreement with that deduced from hard x-ray measurements. By combining the experimental measurements from hard x-rays and the diamagnetic loops, an estimate can be obtained for the volume of a single hot electron ring. The ring volume is determined to be approx. 2.2 litres, and this volume remains approximately constant over the T-mode operating regime. Finally, the power in the electrons scattered out of the ring is measured indirectly by measuring the x-ray radiation produced when those electrons strike the chamber walls. The variation of this radiation with increasing microwave power levels is found to be consistent with classical scattering estimates

  20. The evidence for chronic traumatic encephalopathy in boxing.

    Science.gov (United States)

    McCrory, Paul; Zazryn, Tsharni; Cameron, Peter

    2007-01-01

    The sport of boxing has been the source of much debate, with concerns about the neurological risks of participating having led to many calls to ban the sport. This review seeks to establish an evidence base for the development of boxing-related chronic traumatic encephalopathy (CTE) and to determine the relevance of this information to the modern day sport.The clinical features of CTE include various symptoms affecting the pyramidal and extrapyramidal systems, which manifest most often as disturbed gait and coordination, slurred speech and tremors, as well as cerebral dysfunction causing cognitive impairments and neurobehavioural disturbances. Both amateur and professional boxers are potentially at risk of developing CTE. No current epidemiological evidence exists to determine the prevalence of this condition in modern day boxing, despite 17% of professional boxers in Britain with careers in the 1930-50s having clinical evidence of CTE. As medical presence within the sport increases and with modern boxers likely to have shorter careers, a reduced exposure to repetitive head trauma, and improved treatment and understanding of the development of CTE will occur. This should lead to the incidence of CTE diminishing in boxing populations.

  1. Modelling Hot Air Balloons.

    Science.gov (United States)

    Brimicombe, M. W.

    1991-01-01

    A macroscopic way of modeling hot air balloons using a Newtonian approach is presented. Misleading examples using a car tire and the concept of hot air rising are discussed. Pressure gradient changes in the atmosphere are used to explain how hot air balloons work. (KR)

  2. Design and Development of Smart Medicine Box

    Science.gov (United States)

    Rosli, Ekbal; Husaini, Yusnira

    2018-03-01

    The Smart Medicine Box is successfully designed in helping the introvert patients taking their medicine without help of others. This project is to develop a robotic device that can assist patient to take medicine alone by implementing an IOT apps system for controlling the Smart Medicine Box where it will overcome an emotional disturbance experience by the introvert patients. There are four sensors such as PIR, IR, temperature and ultrasonic sensors use for the project. The purpose of PIR sensor is to detect hand movement near the device, while IR sensor is to detect the line follower on the floor. The LM 35 acts as the detection of the temperature inside the box and the ultrasonic acts as the detection of the obstacle in front of the device. The MIT Apps Invention 2 is used to develop an apps and collect the data from sensors through Arduino microcontroller. A proof of concept design has implemented and demonstrated successfully.

  3. Temperature Characteristics of Porous Portland Cement Concrete during the Hot Summer Session

    Directory of Open Access Journals (Sweden)

    Liqun Hu

    2017-01-01

    Full Text Available Pavement heats the near-surface air and affects the thermal comfort of the human body in hot summer. Because of a large amount of connected porosity of porous Portland cement concrete (PPCC, the thermal parameters of PPCC are much different from those of traditional Portland cement concrete (PCC. The temperature change characteristics of PPCC and the effects on surrounding environment are also different. A continuous 48-hour log of temperature of a PCC and five kinds of PPCC with different porosity were recorded in the open air in the hot summer. The air temperatures at different heights above concrete specimens were tested using self-made enclosed boxes to analyze the characteristics of near-surface air temperature. The output heat flux of different concrete specimens was calculated. The results show that the PPCC has higher temperature in the daytime and lower temperature in the nighttime and larger temperature gradient than the PCC. The air temperature above PPCC is lower than that of PCC after solar radiation going to zero at night. The total output heat flux of PPCC is slightly smaller in the daytime and significantly smaller at night than that of PCC. The results of tests and calculations indicate that PPCC contributes to the mitigation of heating effect of pavement on the near-surface air.

  4. Fitting boxes to Manhattan scenes using linear integer programming

    KAUST Repository

    Li, Minglei

    2016-02-19

    We propose an approach for automatic generation of building models by assembling a set of boxes using a Manhattan-world assumption. The method first aligns the point cloud with a per-building local coordinate system, and then fits axis-aligned planes to the point cloud through an iterative regularization process. The refined planes partition the space of the data into a series of compact cubic cells (candidate boxes) spanning the entire 3D space of the input data. We then choose to approximate the target building by the assembly of a subset of these candidate boxes using a binary linear programming formulation. The objective function is designed to maximize the point cloud coverage and the compactness of the final model. Finally, all selected boxes are merged into a lightweight polygonal mesh model, which is suitable for interactive visualization of large scale urban scenes. Experimental results and a comparison with state-of-the-art methods demonstrate the effectiveness of the proposed framework.

  5. A Novel and Cost Effective Approach to the Decommissioning and Decontamination of Legacy Glove Boxes - Minimizing TRU Waste and Maximizing LLW Waste - 13634

    Energy Technology Data Exchange (ETDEWEB)

    Pancake, Daniel; Rock, Cynthia M.; Creed, Richard [Argonne National Laboratory, 9700 South Cass Avenue, Lemont, IL 60439 (United States); Donohoue, Tom; Martin, E. Ray; Mason, John A. [ANTECH Corporation 9050 Marshall Court, Westminster, CO, 80031 (United States); Norton, Christopher J.; Crosby, Daniel [Environmental Alternatives, Inc., 149 Emerald Street, Suite R, Keene, NH 03431 (United States); Nachtman, Thomas J. [InstaCote, Inc., 160 C. Lavoy Road, Erie, MI, 48133 (United States)

    2013-07-01

    This paper describes the process of decommissioning two gloveboxes at the Argonne National Laboratory (ANL) that were employed for work with plutonium and other radioactive materials. The decommissioning process involved an initial phase of clearing tools and materials from the glove boxes and disconnecting them from the laboratory infrastructure. The removed materials, assessed as Transuranic (TRU) waste, were packaged into 55 gallon (200 litre) drums and prepared for ultimate disposal at the Waste Isolation Pilot Plant (WIPP) at Carlsbad New Mexico. The boxes were then sampled to determine the radioactive contents by means of smears that were counted with alpha and beta detectors to determine the residual surface contamination, especially in terms of alpha particle emitters that are an indicator of TRU activity. Paint chip samples were also collected and sent for laboratory analysis in order to ascertain the radioactive contamination contributing to the TRU activity as a fixed contamination. The investigations predicted that it may be feasible to reduce the residual surface contamination and render the glovebox structure low level waste (LLW) for disposal. In order to reduce the TRU activity a comprehensive decontamination process was initiated using chemical compounds that are particularly effective for lifting and dissolving radionuclides that adhere to the inner surfaces of the gloveboxes. The result of the decontamination process was a reduction in the TRU surface activity on the inner surfaces of the gloveboxes by four orders of magnitude in terms of disintegrations per unit area (DPA). The next phase of the process involved a comprehensive assay of the gloveboxes using a combination of passive neutron and gamma ray scintillation detectors and a shielded and collimated high purity Germanium (HPGe) gamma ray detector. The HPGe detector was used to obtain gamma ray spectra for a variety of measurement positions within the glovebox. The spectra were used to

  6. A Novel and Cost Effective Approach to the Decommissioning and Decontamination of Legacy Glove Boxes - Minimizing TRU Waste and Maximizing LLW Waste - 13634

    International Nuclear Information System (INIS)

    Pancake, Daniel; Rock, Cynthia M.; Creed, Richard; Donohoue, Tom; Martin, E. Ray; Mason, John A.; Norton, Christopher J.; Crosby, Daniel; Nachtman, Thomas J.

    2013-01-01

    This paper describes the process of decommissioning two gloveboxes at the Argonne National Laboratory (ANL) that were employed for work with plutonium and other radioactive materials. The decommissioning process involved an initial phase of clearing tools and materials from the glove boxes and disconnecting them from the laboratory infrastructure. The removed materials, assessed as Transuranic (TRU) waste, were packaged into 55 gallon (200 litre) drums and prepared for ultimate disposal at the Waste Isolation Pilot Plant (WIPP) at Carlsbad New Mexico. The boxes were then sampled to determine the radioactive contents by means of smears that were counted with alpha and beta detectors to determine the residual surface contamination, especially in terms of alpha particle emitters that are an indicator of TRU activity. Paint chip samples were also collected and sent for laboratory analysis in order to ascertain the radioactive contamination contributing to the TRU activity as a fixed contamination. The investigations predicted that it may be feasible to reduce the residual surface contamination and render the glovebox structure low level waste (LLW) for disposal. In order to reduce the TRU activity a comprehensive decontamination process was initiated using chemical compounds that are particularly effective for lifting and dissolving radionuclides that adhere to the inner surfaces of the gloveboxes. The result of the decontamination process was a reduction in the TRU surface activity on the inner surfaces of the gloveboxes by four orders of magnitude in terms of disintegrations per unit area (DPA). The next phase of the process involved a comprehensive assay of the gloveboxes using a combination of passive neutron and gamma ray scintillation detectors and a shielded and collimated high purity Germanium (HPGe) gamma ray detector. The HPGe detector was used to obtain gamma ray spectra for a variety of measurement positions within the glovebox. The spectra were used to

  7. Near space radiation dosimetry in Australian outback using a balloon borne energy compensated PIN diode detector

    International Nuclear Information System (INIS)

    Mukherjee, Bhaskar; Wu, Xiaofeng; Maczka, Tomasz; Kwan, Trevor; Huang, Yijun; Mares, Vladimir

    2016-01-01

    This paper reports the near space ballooning experiment carried out at Australian outback town West Wyalong (33°51′S, 147°24′E) on 19 July 2015. Several dedicated electronic detectors including digital temperature and acceleration (vibration) sensors and an energy compensated PIN-diode gamma ray dosimeter were installed in a thermally insulated Styrofoam payload box. A 9 V Lithium-Polymer battery powered all the devices. The payload box was attached to a helium-filled latex weather balloon and set afloat. The balloon reached a peak burst altitude of 30 km and then soft-landed aided by a self-deploying parachute 66.2 km away form the launch site. The payload box was retrieved and data collected from the electronic sensors analysed. The integrated cosmic ray induced photon ambient dose equivalent recorded by the PIN diode detector was evaluated to be 0.36 ± 0.05 μSv. Furthermore, a high-altitude extended version of commercially available aviation dosimetry package EPCARD.Net (European Program package for the Calculation of Aviation Route Doses) was used to calculate the ambient dose equivalents during the balloon flight. The radiation environment originated from the secondary cosmic ray shower is composed of neutrons, protons, electrons, muons, pions and photons. The photon ambient dose equivalent estimated by the EPCARD.Net code found to be 0.47 ± 0.09 μSv. The important aspects of balloon based near-space radiation dosimetry are highlighted in this paper. - Highlights: • Near space ballooning experiment in Australian outback. • A PIN diode based gamma dosimeter was sent to an altitude of 30 km. • Ambient photon dose equivalent was evaluated as a function of altitude. • Results agreed well with the simulated data delivered by EPCARD.Net Code. • The atmospheric temperature and payload jerks were also assessed.

  8. Nuclear factor ETF specifically stimulates transcription from promoters without a TATA box.

    Science.gov (United States)

    Kageyama, R; Merlino, G T; Pastan, I

    1989-09-15

    Transcription factor ETF stimulates the expression of the epidermal growth factor receptor (EGFR) gene which does not have a TATA box in the promoter region. Here, we show that ETF recognizes various GC-rich sequences including stretches of deoxycytidine or deoxyguanosine residues and GC boxes with similar affinities. ETF also binds to TATA boxes but with a lower affinity. ETF stimulated in vitro transcription from several promoters without TATA boxes but had little or no effect on TATA box-containing promoters even though they had strong ETF-binding sites. These inactive ETF-binding sites became functional when placed upstream of the EGFR promoter whose own ETF-binding sites were removed. Furthermore, when a TATA box was introduced into the EGFR promoter, the responsiveness to ETF was abolished. These results indicate that ETF is a specific transcription factor for promoters which do not contain TATA elements.

  9. Electronics cooling of Phenix multiplicity and vertex detector

    International Nuclear Information System (INIS)

    Chen, Z.; Gregory, W.S.

    1996-08-01

    The Multiplicity and Vertex Detector (MVD) uses silicon strip sensors arranged in two concentric barrels around the beam pipe of the PHENIX detector that will be installed at Brookhaven National Laboratory. Each silicon sensor is connected by a flexible kapton cable to its own front-end electronics printed circuit board that is a multi-chip module or MCM. The MCMs are the main heat source in the system. To maintain the MVD at optimized operational status, the maximum temperature of the multi-chip modules must be below 40 C. Using COSMOS/M HSTAR for the Heat Transfer analysis, a finite element model of a typical MCM plate was created to simulate a 9m/s airflow and 9m/s mixed flow composed of 50% helium and 50% air respectively, with convective heat transfer on both sides of the plate. The results using a mixed flow of helium and air show that the average maximum temperature reached by the MCMs is 37.5 C. The maximum temperature which is represented by the hot spots on the MCM is 39.43 C for the helium and air mixture which meets the design temperature requirement 40 C. To maintain the Multiplicity and Vertex Detector at optimized operational status, the configuration of the plenum chamber, the power dissipated by the silicon chips, the fluid flow velocity and comparison on the MCM design parameters will be discussed

  10. Software Simulation of Hot Tearing

    DEFF Research Database (Denmark)

    Andersen, S.; Hansen, P.N.; Hattel, Jesper Henri

    1999-01-01

    The brittleness of a solidifying alloy in a temperature range near the solidus temperature has been recognised since the fifties as the mechanism responsible for hot tearing. Due to this brittlenes, the metal will crack under even small amounts of strain in that temperature range. We see these hot...... tears in castings close to hot centres, where the level of strain is often too high.Although the hot tearing mechanism is well understood, until now it has been difficult to do much to reduce the hot tearing tendency in a casting. In the seventies, good hot tearing criteria were developed by considering...... the solidification rate and the strain rate of the hot tear prone areas. But, until recently it was only possible to simulate the solidification rate, so that the criteria could not be used effectively.Today, with new software developments, it is possible to also simulate the strain rate in the hot tear prone areas...

  11. Detectors for proton counting. Si-APD and scintillation detectors

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2008-01-01

    Increased intensity of synchrotron radiation requests users to prepare photon pulse detectors having higher counting rates. As detectors for photon counting, silicon-avalanche photodiode (Si-APD) and scintillation detectors were chosen for the fifth series of detectors. Principle of photon detection by pulse and need of amplification function of the detector were described. Structure and working principle, high counting rate measurement system, bunch of electrons vs. counting rate, application example of NMR time spectroscopy measurement and comments for users were described for the Si-APD detector. Structure of scintillator and photomultiplier tube, characteristics of scintillator and performance of detector were shown for the NaI detector. Future development of photon pulse detectors was discussed. (T. Tanaka)

  12. Experimental realization of the quantum box problem

    International Nuclear Information System (INIS)

    Resch, K.J.; Lundeen, J.S.; Steinberg, A.M.

    2004-01-01

    The three-box problem is a gedankenexperiment designed to elucidate some interesting features of quantum measurement and locality. A particle is prepared in a particular superposition of three boxes, and later found in a different (but nonorthogonal) superposition. It was predicted that appropriate 'weak' measurements of particle position in the interval between preparation and post-selection would find the particle in two different places, each with certainty. We verify these predictions in an optical experiment and address the issues of locality and of negative probability

  13. Boxing training for patients with Parkinson disease: a case series.

    Science.gov (United States)

    Combs, Stephanie A; Diehl, M Dyer; Staples, William H; Conn, Lindsay; Davis, Kendra; Lewis, Nicole; Schaneman, Katie

    2011-01-01

    A nontraditional form of exercise recently applied for patients with Parkinson disease (PD) is boxing training. The primary purpose of this case series is to describe the effects of disease severity and duration of boxing training (short term and long term) on changes in balance, mobility, and quality of life for patients with mild or moderate to severe PD. The feasibility and safety of the boxing training program also were assessed. Six patients with idiopathic PD attended 24 to 36 boxing training sessions for 12 weeks, with the option of continuing the training for an additional 24 weeks (a seventh patient attended sessions for only 4 weeks). The 90-minute sessions included boxing drills and traditional stretching, strengthening, and endurance exercises. Outcomes were tested at the baseline and after 12, 24, and 36 weeks of boxing sessions (12-, 24-, and 36-week tests). The outcome measures were the Functional Reach Test, Berg Balance Scale, Activities-specific Balance Confidence Scale, Timed "Up & Go" Test, Six-Minute Walk Test, gait speed, cadence, stride length, step width, activities of daily living and motor examination subscales of the Unified Parkinson Disease Rating Scale, and Parkinson Disease Quality of Life Scale. Six patients completed all phases of the case series, showed improvements on at least 5 of the 12 outcome measures over the baseline at the 12-week test, and showed continued improvements at the 24- and 36-week tests. Patients with mild PD typically showed improvements earlier than those with moderate to severe PD. Despite the progressive nature of PD, the patients in this case series showed short-term and long-term improvements in balance, gait, activities of daily living, and quality of life after the boxing training program. A longer duration of training was necessary for patients with moderate to severe PD to show maximal training outcomes. The boxing training program was feasible and safe for these patients with PD.

  14. Hot tub folliculitis

    Science.gov (United States)

    ... survives in hot tubs, especially tubs made of wood. Symptoms The first symptom of hot tub folliculitis ... may help prevent the problem. Images Hair follicle anatomy References D'Agata E. Pseudomonas aeruginosa and other ...

  15. Gear-box fault detection using time-frequency based methods

    DEFF Research Database (Denmark)

    Odgaard, Peter Fogh; Stoustrup, Jakob

    2015-01-01

    Gear-box fault monitoring and detection is important for optimization of power generation and availability of wind turbines. The current industrial approach is to use condition monitoring systems, which runs in parallel with the wind turbine control system, using expensive additional sensors...... in the gear-box resonance frequency can be detected. Two different time–frequency based approaches are presented in this paper. One is a filter based approach and the other is based on a Karhunen–Loeve basis. Both of them detect the gear-box fault with an acceptable detection delay of maximum 100s, which...... is neglectable compared with the fault developing time....

  16. Replacement of the glove box panel in nuclear fuel reprocessing facility

    International Nuclear Information System (INIS)

    Yamamoto, Masahiko; Shirouzu, Hidetomo; Mori, Eito; Surugaya, Naoki

    2016-05-01

    The panels for visual confirmation of glove box installed at Operation Testing Laboratory in Tokai Reprocessing Plant have been deteriorated and transparencies have been decreased due to the long-term use. Therefore, the glove box panels have been replaced from the view point of preventive maintenance. In the new regulation formulated since the accident at Tokyo Electric Power Company's Fukushima Daiichi Nuclear Power Station, it is demanded that the glove box consists of incombustible or noncombustible materials. In this replacement, the new panels have been manufactured with the polycarbonate which satisfied the UL94 V-0 incombustible class. The glove box has been in service for 40 years and its inside is contaminated with radioactive materials. Thus, the contaminations have been investigated and decontaminated before the replacement work. Then, operator's exposure and radiation protection equipment have been estimated. Also, it is necessary to replace the panels with maintaining the glove box's enclosure function. The replacement has been conducted in closed space covering the opening parts with vinyl sheets. The enclosure function has been verified by the inspection of the new panels and glove box. (author)

  17. Boxing fatalities in relation to rule changes in Japan: secondary data analysis.

    Science.gov (United States)

    Teramoto, Masaru; Cross, Chad L; Cushman, Daniel M; Willick, Stuart E

    2018-01-18

    To examine whether changing weigh-in from the same day of the match to the day before the match and prohibiting 6-oz gloves are associated with fatalities in boxing matches sanctioned by the Japan Boxing Commission (JBC). We analyzed the rates of boxing fatalities before and after the two rule changes above via secondary analysis of data. Demographics and boxing records of deceased boxers were examined using descriptive statistics, exact binomial test the Mann-Whitney-Wilcoxon test and Fisher's exact tests. As of this study, a total of 38 boxers (23.9 ± 3.3 years of age) reportedly died due to injuries sustained in JBC-sanctioned boxing matches since 1952. Changing weigh-in to the day before the match or prohibiting 6-oz gloves was not significantly associated with the rates of boxing fatalities 5 years and 10 years before and after the rule changes (p > 0.05). Deceased boxers after these rule changes were significantly older, completed significantly more rounds in the final match, and were significantly less likely to lose the previous match (prior to the final match) and to do so by knockouts (p boxing fatalities.

  18. Boxing clever

    Energy Technology Data Exchange (ETDEWEB)

    Stanbury, Kate

    1999-09-10

    The outages caused by storms bringing down trees on power transmission lines on Boxing Day 1998 in Scotland, Northern Ireland and Northern England forced ScottishPower to modify its pylon policy. The results of the analysis of pylons requiring work by the Rural Care Team at ScottishPower are summarised, and the identification of the problems caused by the Sitk spruce is reported. The selection of the relocation and clearance remediation option, the policy of replacing one tree with two, the approach to landowners, and the need to consider environmental concerns during the planning of networks are discussed. (UK)

  19. Roof Box Shape Streamline Adaptation and the Impact towards Fuel Consumption

    Directory of Open Access Journals (Sweden)

    Abdul Latif M.F.

    2017-01-01

    Full Text Available The fuel price hike is currently a sensational national issue in Malaysia. Since the rationalization of fuel subsidies many were affected especially the middle income family. Vehicle aerodynamic were directly related to the fuel consumption, were extra frontal area result a higher drag force hence higher fuel consumption. Roof box were among the largest contributor to the extra drag, thus the roof box shape rationalization were prominent to reduce the extra drag. The idea of adopting water drop shape to the roof box design shows prominent result. The roof box has been simulated using MIRA virtual wind tunnel modelling via commercial computational fluid dynamic (CFD package. This streamline shape drastically reduce the drag force by 34% resulting to a 1.7% fuel saving compare to the conventional boxy roof box. This is an effort to reduce the carbon foot print for a sustainable green world.

  20. A New Virtual Point Detector Concept for a HPGe detector

    International Nuclear Information System (INIS)

    Byun, Jong In; Yun, Ju Yong

    2009-01-01

    For last several decades, the radiation measurement and radioactivity analysis techniques using gamma detectors have been well established. Especially , the study about the detection efficiency has been done as an important part of gamma spectrometry. The detection efficiency depends strongly on source-to-detector distance. The detection efficiency with source-to-detector distance can be expressed by a complex function of geometry and physical characteristics of gamma detectors. In order to simplify the relation, a virtual point detector concept was introduced by Notea. Recently, further studies concerning the virtual point detector have been performed. In previous other works the virtual point detector has been considered as a fictitious point existing behind the detector end cap. However the virtual point detector position for the front and side of voluminous detectors might be different due to different effective central axis of them. In order to more accurately define the relation, therefore, we should consider the virtual point detector for the front as well as side and off-center of the detector. The aim of this study is to accurately define the relation between the detection efficiency and source-to-detector distance with the virtual point detector. This paper demonstrates the method to situate the virtual point detectors for a HPGe detector. The new virtual point detector concept was introduced for three area of the detector and its characteristics also were demonstrated by using Monte Carlo Simulation method. We found that the detector has three virtual point detectors except for its rear area. This shows that we should consider the virtual point detectors for each area when applying the concept to radiation measurement. This concept can be applied to the accurate geometric simplification for the detector and radioactive sources.

  1. Hot conditioning equipment conceptual design report

    International Nuclear Information System (INIS)

    Bradshaw, F.W.

    1996-01-01

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage

  2. Hot conditioning equipment conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    Bradshaw, F.W., Westinghouse Hanford

    1996-08-06

    This report documents the conceptual design of the Hot Conditioning System Equipment. The Hot conditioning System will consist of two separate designs: the Hot Conditioning System Equipment; and the Hot Conditioning System Annex. The Hot Conditioning System Equipment Design includes the equipment such as ovens, vacuum pumps, inert gas delivery systems, etc.necessary to condition spent nuclear fuel currently in storage in the K Basins of the Hanford Site. The Hot Conditioning System Annex consists of the facility of house the Hot Conditioning System. The Hot Conditioning System will be housed in an annex to the Canister Storage Building. The Hot Conditioning System will consist of pits in the floor which contain ovens in which the spent nuclear will be conditioned prior to interim storage.

  3. Enhancing Security of Double Random Phase Encoding Based on Random S-Box

    Science.gov (United States)

    Girija, R.; Singh, Hukum

    2018-06-01

    In this paper, we propose a novel asymmetric cryptosystem for double random phase encoding (DRPE) using random S-Box. While utilising S-Box separately is not reliable and DRPE does not support non-linearity, so, our system unites the effectiveness of S-Box with an asymmetric system of DRPE (through Fourier transform). The uniqueness of proposed cryptosystem lies on employing high sensitivity dynamic S-Box for our DRPE system. The randomness and scalability achieved due to applied technique is an additional feature of the proposed solution. The firmness of random S-Box is investigated in terms of performance parameters such as non-linearity, strict avalanche criterion, bit independence criterion, linear and differential approximation probabilities etc. S-Boxes convey nonlinearity to cryptosystems which is a significant parameter and very essential for DRPE. The strength of proposed cryptosystem has been analysed using various parameters such as MSE, PSNR, correlation coefficient analysis, noise analysis, SVD analysis, etc. Experimental results are conferred in detail to exhibit proposed cryptosystem is highly secure.

  4. Transmutation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Viererbl, L., E-mail: vie@ujv.c [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Lahodova, Z. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Klupak, V. [Nuclear Research Institute Rez plc (Czech Republic); Sus, F. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Kucera, J. [Research Centre Rez Ltd. (Czech Republic); Nuclear Physics Institute, Academy of Sciences of the Czech Republic (Czech Republic); Kus, P.; Marek, M. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic)

    2011-03-11

    We have designed a new type of detectors, called transmutation detectors, which can be used primarily for neutron fluence measurement. The transmutation detector method differs from the commonly used activation detector method in evaluation of detector response after irradiation. Instead of radionuclide activity measurement using radiometric methods, the concentration of stable non-gaseous nuclides generated by transmutation in the detector is measured using analytical methods like mass spectrometry. Prospective elements and nuclear reactions for transmutation detectors are listed and initial experimental results are given. The transmutation detector method could be used primarily for long-term measurement of neutron fluence in fission nuclear reactors, but in principle it could be used for any type of radiation that can cause transmutation of nuclides in detectors. This method could also be used for measurement in accelerators or fusion reactors.

  5. Transmutation detectors

    International Nuclear Information System (INIS)

    Viererbl, L.; Lahodova, Z.; Klupak, V.; Sus, F.; Kucera, J.; Kus, P.; Marek, M.

    2011-01-01

    We have designed a new type of detectors, called transmutation detectors, which can be used primarily for neutron fluence measurement. The transmutation detector method differs from the commonly used activation detector method in evaluation of detector response after irradiation. Instead of radionuclide activity measurement using radiometric methods, the concentration of stable non-gaseous nuclides generated by transmutation in the detector is measured using analytical methods like mass spectrometry. Prospective elements and nuclear reactions for transmutation detectors are listed and initial experimental results are given. The transmutation detector method could be used primarily for long-term measurement of neutron fluence in fission nuclear reactors, but in principle it could be used for any type of radiation that can cause transmutation of nuclides in detectors. This method could also be used for measurement in accelerators or fusion reactors.

  6. Nonequilibrium phenomena and determination of plasma parameters in the hot core of the cathode region in free-burning arc discharges

    International Nuclear Information System (INIS)

    Kuehn, Gerrit; Kock, Manfred

    2007-01-01

    We present spectroscopic measurements of plasma parameters (electron density n e , electron temperature T e , gas temperature T g , underpopulation factor b) in the hot-core region in front of the cathode of a low-current, free-burning arc discharge in argon under atmospheric pressure. The discharge is operated in the hot-core mode, creating a hot cathode region with plasma parameters similar to high-current arcs in spite of the fact that we use comparatively low currents (less than 20 A). We use continuum emission and (optically thin) line emission to determine n e and T e . We apply relaxation measurements based on a power-interruption technique to investigate deviations from local thermodynamic equilibrium (LTE). These measurements let us determine the gas temperature T g . All measurements are performed side-on with charge-coupled-device cameras as detectors, so that all measured plasma parameters are spatially resolved after an Abel inversion. This yields the first ever spatially resolved observation of the non-LTE phenomena of the hot core in the near-cathode region of free-burning arcs. The results only partly coincide with previously published predictions and measurements in the literature

  7. A novel method of S-box design based on chaotic map and composition method

    International Nuclear Information System (INIS)

    Lambić, Dragan

    2014-01-01

    Highlights: • Novel chaotic S-box generation method is presented. • Presented S-box has better cryptographic properties than other examples of chaotic S-boxes. • The advantages of the proposed method are the low complexity and large key space. -- Abstract: An efficient algorithm for obtaining random bijective S-boxes based on chaotic maps and composition method is presented. The proposed method is based on compositions of S-boxes from a fixed starting set. The sequence of the indices of starting S-boxes used is obtained by using chaotic maps. The results of performance test show that the S-box presented in this paper has good cryptographic properties. The advantages of the proposed method are the low complexity and the possibility to achieve large key space

  8. CASAS: A Smart Home in a Box.

    Science.gov (United States)

    Cook, Diane J; Crandall, Aaron S; Thomas, Brian L; Krishnan, Narayanan C

    2013-07-01

    While the potential benefits of smart home technology are widely recognized, a lightweight design is needed for the benefits to be realized at a large scale. We introduce the CASAS "smart home in a box", a lightweight smart home design that is easy to install and provides smart home capabilities out of the box with no customization or training. We discuss types of data analysis that have been performed by the CASAS group and can be pursued in the future by using this approach to designing and implementing smart home technologies.

  9. The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures

    Science.gov (United States)

    Stephenson, W. Kirk

    2009-01-01

    A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes. (Contains 4 notes.)

  10. 49 CFR 215.107 - Defective plain bearing box: General.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Defective plain bearing box: General. 215.107... Suspension System § 215.107 Defective plain bearing box: General. A railroad may not place or continue in... the bearing; or (2) Have a detrimental effect on the lubrication of the journal and the bearings. ...

  11. Microbiologically influenced corrosion in condenser water boxes at Crystal River-3

    International Nuclear Information System (INIS)

    Hayner, G.O.; Pope, D.H.; Crane, B.E.

    1988-01-01

    During the spring of 1986, several welds in the lower half of the condenser inlet water boxes at Crystal River-3 (CR-3) were found to be seeping seawater. The leakage produced red-brown and black-green colored deposits on the outside surface of the water boxes. The welds in affected areas were not uniformly attacked, and the severity of attack varied between water boxes; however, there were instances of attack on each type of pressure-retaining weld in the affected regions. Weld seepage was also seen on the outside of the inlet piping to the water boxes. A few small pin holes were seen in the base metal of the water boxes not associated with welds. In this paper the authors report the results of examinations performed at both the CR-3 site and at The Babcock and Wilcox Company Lynchburt Research Center (LRC). The inside of a water box and the exterior of the condenser inlet piping were visually inspected at the Cr-3 site. Nodules inside the water box were probed and examined. Parts of nodules were collected and microscopically examined for bacteria. Two corrosion-deposit samples removed from condenser instrument piping and the condenser inlet piping were chemically analyzed at the LRC. Four pipe samples removed from the condenser instrument piping were destructively examined at the LRC. This work included visual inspection, metallographic, scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS) examinations performed on selected locations of the piping samples

  12. Nuclear Fragmentation Induced by Relativistic Projectiles Studied in the 4$\\pi$ Configuration of Plastic Track Detectors

    CERN Multimedia

    2002-01-01

    % EMU19 \\\\ \\\\ The collisions of heavy ions at relativistic energies have been studied to explore a number of questions related with hot and dense nuclear matter in order to extend our knowledge of nuclear equation-of-state. There are other aspects of these interactions which are studied to expound the process of projectile and/or target disintegrations. The disintegrations in question could be simply binary fissions or more complex processes leading to spallation or complete fragmentation. These important aspects of nuclear reactions are prone to investigations with nuclear track detectors. \\\\ \\\\One of the comparatively new track detector materials, CR-39, is sensitive enough to record particles of Z~$\\geq$~6 with almost 100\\% efficiency up to highly relativistic energies. The wide angle acceptance and exclusive measurements possible with plastic track detectors offer an opportunity to use them in a variety of situations in which high energy charged fragments are produced. The off-line nature of measuring tra...

  13. Decay spectroscopy at SHIP with a new focal plane detector system

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, Andrew K. [Helmholtz Institute Mainz (Germany); Collaboration: SHIP Decay Spectroscopy-Collaboration

    2016-07-01

    Decay spectroscopy of the heaviest elements remains a crucial tool in nuclear structure physics in testing a variety of theoretical models predicting the next proton and neutron shell stabilization region beyond {sup 208}Pb. Experimental measurements of alpha-decay energies and half-lives, ordering and configurations of ground state and excited levels, and the determination of high-K isomers provide necessary information in constraining these models. To this end, a new focal plane detection system for decay spectroscopy has been designed and developed at GSI for the SHIP separator. It consists of a double sided silicon strip implantation detector surrounded by 4 single sided silicon strip detectors on each side in a box formation with a compact design, allowing for good germanium solid angle coverage for gamma ray detection. The data acquisition is based on FEBEX flash ADC modules, developed at GSI, for digital signal processing enables an almost deadtime free system. Recently, a commissioning run was successfully performed using the device. In my talk I present recent highlights of decay spectroscopy at SHIP, and demonstrate results from measurements assessing the performance of the new setup.

  14. Two high-mobility group box domains act together to underwind and kink DNA

    Energy Technology Data Exchange (ETDEWEB)

    Sánchez-Giraldo, R.; Acosta-Reyes, F. J. [Universitat Politecnica de Catalunya, 08028 Barcelona (Spain); Malarkey, C. S. [University of Colorado School of Medicine, Aurora, CO 80045 (United States); Saperas, N. [Universitat Politecnica de Catalunya, 08028 Barcelona (Spain); Churchill, M. E. A., E-mail: mair.churchill@ucdenver.edu [University of Colorado School of Medicine, Aurora, CO 80045 (United States); Campos, J. L., E-mail: mair.churchill@ucdenver.edu [Universitat Politecnica de Catalunya, 08028 Barcelona (Spain)

    2015-06-30

    The crystal structure of HMGB1 box A bound to an unmodified AT-rich DNA fragment is reported at a resolution of 2 Å. A new mode of DNA recognition for HMG box proteins is found in which two box A domains bind in an unusual configuration generating a highly kinked DNA structure. High-mobility group protein 1 (HMGB1) is an essential and ubiquitous DNA architectural factor that influences a myriad of cellular processes. HMGB1 contains two DNA-binding domains, box A and box B, which have little sequence specificity but have remarkable abilities to underwind and bend DNA. Although HMGB1 box A is thought to be responsible for the majority of HMGB1–DNA interactions with pre-bent or kinked DNA, little is known about how it recognizes unmodified DNA. Here, the crystal structure of HMGB1 box A bound to an AT-rich DNA fragment is reported at a resolution of 2 Å. Two box A domains of HMGB1 collaborate in an unusual configuration in which the Phe37 residues of both domains stack together and intercalate the same CG base pair, generating highly kinked DNA. This represents a novel mode of DNA recognition for HMGB proteins and reveals a mechanism by which structure-specific HMG boxes kink linear DNA.

  15. Two high-mobility group box domains act together to underwind and kink DNA

    International Nuclear Information System (INIS)

    Sánchez-Giraldo, R.; Acosta-Reyes, F. J.; Malarkey, C. S.; Saperas, N.; Churchill, M. E. A.; Campos, J. L.

    2015-01-01

    The crystal structure of HMGB1 box A bound to an unmodified AT-rich DNA fragment is reported at a resolution of 2 Å. A new mode of DNA recognition for HMG box proteins is found in which two box A domains bind in an unusual configuration generating a highly kinked DNA structure. High-mobility group protein 1 (HMGB1) is an essential and ubiquitous DNA architectural factor that influences a myriad of cellular processes. HMGB1 contains two DNA-binding domains, box A and box B, which have little sequence specificity but have remarkable abilities to underwind and bend DNA. Although HMGB1 box A is thought to be responsible for the majority of HMGB1–DNA interactions with pre-bent or kinked DNA, little is known about how it recognizes unmodified DNA. Here, the crystal structure of HMGB1 box A bound to an AT-rich DNA fragment is reported at a resolution of 2 Å. Two box A domains of HMGB1 collaborate in an unusual configuration in which the Phe37 residues of both domains stack together and intercalate the same CG base pair, generating highly kinked DNA. This represents a novel mode of DNA recognition for HMGB proteins and reveals a mechanism by which structure-specific HMG boxes kink linear DNA

  16. Improving Eastern Bluebird nest box performance using computer analysis of satellite images

    Directory of Open Access Journals (Sweden)

    Sarah Svatora

    2012-06-01

    Full Text Available Bird conservationists have been introducing man-made boxes in an effort to increase the bluebird population. In this study we use computer analysis of satellite images to show that the performance of the boxes used by Eastern Bluebirds (Sialia sialis in Michigan can be improved by about 48%. The analysis is based on a strongcorrelation found between the edge directionality measured in the satellite image of the area around the box, and the preferences of the birds when selecting their nesting site. The method is based on satellite images taken from Google Earth, and can be used by conservationists to select a box placement strategy that will optimize the efficacy of the boxes deployed in a given area.

  17. Functions of DEAD-box proteins in bacteria: current knowledge and pending questions.

    Science.gov (United States)

    Iost, Isabelle; Bizebard, Thierry; Dreyfus, Marc

    2013-08-01

    DEAD-box proteins are RNA-dependent ATPases that are widespread in all three kingdoms of life. They are thought to rearrange the structures of RNA or ribonucleoprotein complexes but their exact mechanism of action is rarely known. Whereas in yeast most DEAD-box proteins are essential, no example of an essential bacterial DEAD-box protein has been reported so far; at most, their absence results in cold-sensitive growth. Moreover, whereas yeast DEAD-box proteins are implicated in virtually all reactions involving RNA, in E. coli (the bacterium where DEAD-box proteins have been mostly studied) their role is limited to ribosome biogenesis, mRNA degradation, and possibly translation initiation. Plausible reasons for these differences are discussed here. In spite of their dispensability, E. coli DEAD-box proteins are valuable models for the mechanism of action of DEAD-box proteins in general because the reactions in which they participate can be reproduced in vitro. Here we review our present understanding of this mechanism of action. Using selected examples for which information is available: (i) we describe how, by interacting directly with a particular RNA motif or by binding to proteins that themselves recognize such a motif, DEAD-box proteins are brought to their specific RNA substrate(s); (ii) we discuss the nature of the structural transitions that DEAD-box proteins induce on their substrates; and (iii) we analyze the reasons why these proteins are mostly important at low temperatures. This article is part of a Special Issue entitled: The Biology of RNA helicases-Modulation for life. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Secure image encryption algorithm design using a novel chaos based S-Box

    International Nuclear Information System (INIS)

    Çavuşoğlu, Ünal; Kaçar, Sezgin; Pehlivan, Ihsan; Zengin, Ahmet

    2017-01-01

    Highlights: • A new chaotic system is developed for creating S-Box and image encryption algorithm. • Chaos based random number generator is designed with the help of the new chaotic system. NIST tests are run on generated random numbers to verify randomness. • A new S-Box design algorithm is developed to create the chaos based S-Box to be utilized in encryption algorithm and performance tests are made. • The new developed S-Box based image encryption algorithm is introduced and image encryption application is carried out. • To show the quality and strong of the encryption process, security analysis are performed and compared with the AES and chaos algorithms. - Abstract: In this study, an encryption algorithm that uses chaos based S-BOX is developed for secure and speed image encryption. First of all, a new chaotic system is developed for creating S-Box and image encryption algorithm. Chaos based random number generator is designed with the help of the new chaotic system. Then, NIST tests are run on generated random numbers to verify randomness. A new S-Box design algorithm is developed to create the chaos based S-Box to be utilized in encryption algorithm and performance tests are made. As the next step, the new developed S-Box based image encryption algorithm is introduced in detail. Finally, image encryption application is carried out. To show the quality and strong of the encryption process, security analysis are performed. Proposed algorithm is compared with the AES and chaos algorithms. According to tests results, the proposed image encryption algorithm is secure and speed for image encryption application.

  19. Detector Control System for the ATLAS Forward Proton detector

    CERN Document Server

    Czekierda, Sabina; The ATLAS collaboration

    2017-01-01

    The ATLAS Forward Proton (AFP) is a forward detector using a Roman Pot technique, recently installed in the LHC tunnel. It is aiming at registering protons that were diffractively or electromagnetically scattered in soft and hard processes. Infrastructure of the detector consists of hardware placed both in the tunnel and in the control room USA15 (about 330 meters from the Roman Pots). AFP detector, like the other detectors of the ATLAS experiment, uses the Detector Control System (DCS) to supervise the detector and to ensure its safe and coherent operation, since the incorrect detector performance may influence the physics results. The DCS continuously monitors the detector parameters, subset of which is stored in data bases. Crucial parameters are guarded by alarm system. A detector representation as a hierarchical tree-like structure of well-defined subsystems built with the use of the Finite State Machine (FSM) toolkit allows for overall detector operation and visualization. Every node in the hierarchy is...

  20. Striking dynamics and kinetic properties of boxing and MMA gloves

    Directory of Open Access Journals (Sweden)

    Benjamin Lee

    2014-08-01

    Full Text Available With the growing popularity of Mixed Martial Arts (MMA as a competitive sport, questions regarding the dynamic response and properties of MMA gloves arise. High-energy impacts from punches are very similar to boxing yet MMA competition requires the use of 4 oz fingerless glove, compared to the larger full enclosure boxing glove. This work assessed the kinetic properties and strike dynamics of MMA gloves and compared findings with traditional boxing gloves. Gloves mounted on a molded fist were impacted repetitively on an instrumental anvil designed for impact, over a 5 hour period resulting in 10,000 continuous and consistent strikes. Kinetic data from impacts were sampled at the beginning of the data collection and subsequently every 30 minutes (every 1,000 strikes. MMA gloves produced 4-5 times greater peak force and 5 times faster load rate compared to the boxing glove. However, MMA gloves also showed signs of material fatigue, with peak force increasing by 35% and rate of loading increasing by 60% over the duration of the test. Boxing glove characteristics did deteriorate but to a lesser extent. In summary, the kinetic properties of MMA glove differed substantially from the boxing glove resulting in impacts characterized by higher peak forces and more rapid development of force. Material properties including stiffness and thickness play a role in the kinetic characteristics upon impact, and can be inferred to alter injury mechanisms of blunt force trauma.