WorldWideScience

Sample records for horizontal test stand

  1. Variable Attitude Test Stand

    Data.gov (United States)

    Federal Laboratory Consortium — The Variable Attitude Test Stand designed and built for testing of the V-22 tilt rotor aircraft propulsion system, is used to evaluate the effect of aircraft flight...

  2. Multi-Purpose Test Stand

    Data.gov (United States)

    Federal Laboratory Consortium — The Multi-Purpose Test Stand is used for a wide variety of tests. The Stand is designed to be rotated through a range of fixed yaw positions to allow engines to be...

  3. Analysis of tree stand horizontal structure using random point field methods

    Directory of Open Access Journals (Sweden)

    O. P. Sekretenko

    2015-06-01

    Full Text Available This paper uses the model approach to analyze the horizontal structure of forest stands. The main types of models of random point fields and statistical procedures that can be used to analyze spatial patterns of trees of uneven and even-aged stands are described. We show how modern methods of spatial statistics can be used to address one of the objectives of forestry – to clarify the laws of natural thinning of forest stand and the corresponding changes in its spatial structure over time. Studying natural forest thinning, we describe the consecutive stages of modeling: selection of the appropriate parametric model, parameter estimation and generation of point patterns in accordance with the selected model, the selection of statistical functions to describe the horizontal structure of forest stands and testing of statistical hypotheses. We show the possibilities of a specialized software package, spatstat, which is designed to meet the challenges of spatial statistics and provides software support for modern methods of analysis of spatial data. We show that a model of stand thinning that does not consider inter-tree interaction can project the size distribution of the trees properly, but the spatial pattern of the modeled stand is not quite consistent with observed data. Using data of three even-aged pine forest stands of 25, 55, and 90-years old, we demonstrate that the spatial point process models are useful for combining measurements in the forest stands of different ages to study the forest stand natural thinning.

  4. Using a stand-level model to predict light absorption in stands with vertically and horizontally heterogeneous canopies

    Directory of Open Access Journals (Sweden)

    David I Forrester

    2014-09-01

    Full Text Available Background Forest ecosystem functioning is strongly influenced by the absorption of photosynthetically active radiation (APAR, and therefore, accurate predictions of APAR are critical for many process-based forest growth models. The Lambert-Beer law can be applied to estimate APAR for simple homogeneous canopies composed of one layer, one species, and no canopy gaps. However, the vertical and horizontal structure of forest canopies is rarely homogeneous. Detailed tree-level models can account for this heterogeneity but these often have high input and computational demands and work on finer temporal and spatial resolutions than required by stand-level growth models. The aim of this study was to test a stand-level light absorption model that can estimate APAR by individual species in mixed-species and multi-layered stands with any degree of canopy openness including open-grown trees to closed canopies. Methods The stand-level model was compared with a detailed tree-level model that has already been tested in mixed-species stands using empirical data. Both models were parameterised for five different forests, including a wide range of species compositions, species proportions, stand densities, crown architectures and canopy structures. Results The stand-level model performed well in all stands except in the stand where extinction coefficients were unusually variable and it appears unlikely that APAR could be predicted in such stands using (tree- or stand-level models that do not allow individuals of a given species to have different extinction coefficients, leaf-area density or analogous parameters. Conclusion This model is parameterised with species-specific information about extinction coefficients and mean crown length, diameter, height and leaf area. It could be used to examine light dynamics in complex canopies and in stand-level growth models.

  5. A-1 Test Stand work

    Science.gov (United States)

    2010-01-01

    Employees at NASA's John C. Stennis Space Center work to maneuver a structural steam beam into place on the A-1 Test Stand on Jan. 13. The beam was one of several needed to form the thrust takeout structure that will support a new thrust measurement system being installed on the stand for future rocket engine testing. Once lifted onto the stand, the beams had to be hoisted into place through the center of the test stand, with only two inches of clearance on each side. The new thrust measurement system represents a state-of-the-art upgrade from the equipment installed more than 40 years ago when the test stand was first constructed.

  6. An Induction Linac Test Stand

    CERN Document Server

    De Hope, William; Kihara, Ron; Ong, Mike; Vogtlin, George; Zentler, Jan-Mark

    2005-01-01

    A single-cell test stand has been constructed to facilitate study and guide improvements of the induction electron linac at the FXR radiographic facility at LLNL.* This paper will discuss how modifications in pulse compression and shaping, pulse power transmission, initial ferrite state, and accelerator cell loading have been performed on the test stand and can be applied to the entire accelerator. Some of the specialized diagnostics being used will be described. Finally, the paper will discuss how computer modeling and judicious timing control can be used to optimize accelerator performance by making only selective changes that can be accomplished at minimal cost.

  7. A3 TEST STAND CONSTRUCTION

    Science.gov (United States)

    2008-01-01

    THIS IMAGE SHOWS THE DEVELOPMENT AND CONSTRUCTION OF THE A3 TEST STAND IN SUPPORT OF THE ARES/CLV UPPER STAGE ENGINE AT STENNIS SPACE CENTER, MISSISSIPPI. THIS IMAGE IS EXTRACTED FROM A HIGH DEFINITION VIDEO FILE AND IS THE HIGHEST RESOLUTION AVAILABLE.

  8. Quantifying vertical and horizontal stand structure using terrestrial LiDAR in Pacific Northwest forests

    Science.gov (United States)

    Kazakova, Alexandra N.

    Stand level spatial distribution is a fundamental part of forest structure that influences many ecological processes and ecosystem functions. Vertical and horizontal spatial structure provides key information for forest management. Although horizontal stand complexity can be measured through stem mapping and spatial analysis, vertical complexity within the stand remains a mostly visual and highly subjective process. Tools and techniques in remote sensing, specifically LiDAR, provide three dimensional datasets that can help get at three dimensional forest stand structure. Although aerial LiDAR (ALS) is the most widespread form of remote sensing for measuring forest structure, it has a high omission rate in dense and structurally complex forests. In this study we used terrestrial LiDAR (TLS) to obtain high resolution three dimensional point clouds of plots from stands that vary by density and composition in the second-growth Pacific Northwest forest ecosystem. We used point cloud slicing techniques and object-based image analysis (OBIA) to produce canopy profiles at multiple points of vertical gradient. At each height point we produced segments that represented canopies or parts of canopies for each tree within the dataset. The resulting canopy segments were further analyzed using landscape metrics to quantify vertical canopy complexity within a single stand. Based on the developed method, we have successfully created a tool that utilizes three dimensional spatial information to accurately quantify the vertical structure of forest stands. Results show significant differences in the number and the total area of the canopy segments and gap fraction between each vertical slice within and between individual forest management plots. We found a significant relationship between the stand density and composition and the vertical canopy complexity. The methods described in this research make it possible to create horizontal stand profiles at any point along the vertical

  9. Steel erected at A-3 Test Stand

    Science.gov (United States)

    2008-01-01

    Workers erect the first fabricated steel girders to arrive at the A-3 Test Stand at Stennis Space Center. Steel work began at the construction site Oct. 29 and is scheduled to continue into next spring.

  10. A3 TEST STAND DEVELOPMENT AND CONSTRUCTION

    Science.gov (United States)

    2008-01-01

    THIS IMAGE DOCUMENTS THE DEVELOPMENT AND CONSTRUCTION OF THE A3 TEST STAND IN SUPPORT OF THE ARES/CLV UPPER STAGE ENGINE DEVELOPMENT AT STENNIS SPACE CENTER, MISSIPPI IN SUPPORT OF THE DEVELOPMENT OF THE CONSTELLATION/ARES PROJECT. THIS IMAGE IS EXTRACTED FROM A HIGH DEFINITION VIDEO FILE AND IS THE HIGHEST RESOLUTION AVAILABLE

  11. Test Stand for Linear Induction Accelerator Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Ong, M; DeHope, B; Griffin, K; Goerz, D; Kihara, R; Vogtlin, G; Zentler, J M; Scarpetti, R

    2003-06-03

    Lawrence Livermore National Laboratory has designed and constructed a test stand to improve the voltage regulation in our Flash X-Ray (FXR) accelerator cell. The goal is to create a more mono-energetic electron beam that will create an x-ray source with a smaller spot size. Studying the interaction of the beam and pulse-power system with the accelerator cell will improve the design of high-current accelerators at Livermore and elsewhere. On the test stand, a standard FXR cell is driven by a flexible pulse-power system and the beam current is simulated with a switched center conductor. The test stand is fully instrumented with high-speed digitizers to document the effect of impedance mismatches when the cell is operated under various full-voltage conditions. A time-domain reflectometry technique was also developed to characterize the beam and cell interactions by measuring the impedance of the accelerator and pulse-power component. Computer models are being developed in parallel with the testing program to validate the measurements and evaluate different design changes. Both 3D transient electromagnetic and circuit models are being used.

  12. Stand for testing sections of mechanized timbering

    Energy Technology Data Exchange (ETDEWEB)

    Grebennikov, Yu.N.; Aksenov, Yu.G.; Khazanov, Kh.I.; Khazin, V.A.; Radulov, V.Ye.; Vavilov, V.V.

    1982-01-01

    The purpose of the invention is to bring the testing conditions closer to the operating with multiple loading. This goal is achieved because in the stand for testing sections of mechanized timbering which includes a power frame, loading device with support and hydraulic equipment, the loading device is made in the form of enclosure sprockets and infinite mobile gears surrounding them on which with variable spacing with the help of transverse planks there are supports attached. In this case the length of the enclosure of each gear is the aliquant to the spacing of its advance.

  13. FERMILAB CRYOMODULE TEST STAND RF INTERLOCK SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Petersen, Troy [Fermilab; Diamond, J. S. [Fermilab; McDowell, D. [Fermilab; Nicklaus, D. [Fermilab; Prieto, P. S. [Fermilab; Semenov, A. [Fermilab

    2016-10-12

    An interlock system has been designed for the Fermilab Cryo-module Test Stand (CMTS), a test bed for the cryo- modules to be used in the upcoming Linac Coherent Light Source 2 (LCLS-II) project at SLAC. The interlock system features 8 independent subsystems, one per superconducting RF cavity and solid state amplifier (SSA) pair. Each system monitors several devices to detect fault conditions such as arcing in the waveguides or quenching of the SRF system. Additionally each system can detect fault conditions by monitoring the RF power seen at the cavity coupler through a directional coupler. In the event of a fault condition, each system is capable of removing RF signal to the amplifier (via a fast RF switch) as well as turning off the SSA. Additionally, each input signal is available for re- mote viewing and recording via a Fermilab designed digitizer board and MVME 5500 processor.

  14. Horizonte

    OpenAIRE

    BABIANO MARTÍNEZ, CARLOS JOSÉ

    2015-01-01

    Este proyecto intenta ahondar en la idea de horizonte tratado desde la filosofía japonesa y de su nexo con el mundo occidental. De la necesidad latente de una restructuración de la educación para convertirla en una educación estética capaz de permitir a los individuos completarse plenamente como personas. A través de las enseñanzas orientales del zen, del haiku, de filósofos como Tanizaki, y sus ideas sobre la sombra y la sugerencia, frente a Kierkegaard o Schiller en el lado occidental y sus...

  15. Stand for testing the electrical race car engine

    Science.gov (United States)

    Baier, M.; Franiasz, J.; Mierzwa, P.; Wylenzek, D.

    2015-11-01

    An engine test stand created especially for research of electrical race car is described in the paper. The car is an aim of Silesian Greenpower project whose participants build and test electrical vehicles to take part in international races in Great Britain. The engine test stand is used to test and measure the characteristics of vehicles and their engines. It has been designed particularly to test the electric cars engineered by students of Silesian Greenpower project. The article contains a description how the test stand works and shows its versatility in many areas. The paper presents both construction of the test stand, control system and sample results of conducted research. The engine test stand was designed and modified using PLM Siemens NX 8.5. The construction of the test stand is highly modular, which means it can be used both for testing the vehicle itself or for tests without the vehicle. The test stand has its own wheel, motor, powertrain and braking system with second engine. Such solution enables verifying various concepts without changing the construction of the vehicle. The control system and measurement system are realized by enabling National Instruments product myRIO (RIO - Reconfigurable Input/Output). This controller in combination with powerful LabVIEW environment performs as an advanced tool to control torque and speed simultaneously. It is crucial as far as the test stand is equipped in two motors - the one being tested and the braking one. The feedback loop is realized by an optical encoder cooperating with the rotor mounted on the wheel. The results of tests are shown live on the screen both as a chart and as single values. After performing several tests there is a report generated. The engine test stand is widely used during process of the Silesian Greenpower vehicle design. Its versatility enables powertrain testing, wheels and tires tests, thermal analysis and more.

  16. Isopropyl alcohol tank installed at A-3 Test Stand

    Science.gov (United States)

    2009-01-01

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  17. Horizontal lang two-pencil test as a screening test for stereopsis and binocularity

    OpenAIRE

    Nongpiur, Monisha E; Sharma, Pradeep

    2010-01-01

    Purpose: To assess the horizontal Lang two-pencil test as a bedside test to detect gross stereopsis. Materials and Methods: Eighty-four strabismic subjects divided into two groups based on the amount of deviation, and 40 normal subjects were studied. Sensory status examination including binocularity and stereopsis were evaluated with Bagolini, Titmus test and the Netherlands organisation for applied scientific research (TNO), Randot, synoptophore and horizontal Lang two-pencil test. Resul...

  18. Engine Test Stand Design Constraints Expert System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Propulsion test stands are designed for thermal and pressure loads for certain classes of engines. These plume induced loads are: radiative heating, acoustics and...

  19. The stand-alone test and decreasing serial cost sharing

    DEFF Research Database (Denmark)

    Hougaard, Jens Leth; Thorlund-Petersen, Lars

    2000-01-01

    The rule of decreasing serial cost sharing defined in de Frutos [1] over the class of concave cost functions may violate the important stand-alone test. Sufficient conditions for the test to be satisfied are given, in terms of individual rationality as well as coalitional stability. These conditi......The rule of decreasing serial cost sharing defined in de Frutos [1] over the class of concave cost functions may violate the important stand-alone test. Sufficient conditions for the test to be satisfied are given, in terms of individual rationality as well as coalitional stability....... These conditions restrict the shape of the cost function and the distribution of demands...

  20. FTA analysis of the failure in the horizontal fluidity test

    Directory of Open Access Journals (Sweden)

    Peter Blaško

    2015-12-01

    Full Text Available The purpose of the paper was to evaluate the probability of the top event in the fluidity test by Fault Tree Analysis (FTA. One of the important tests used in the foundry practice is the test of the fluidity. Fluidity is the ability of the molten metal to fill the cavity of the molds and create a cast. The AlSi10MgMn (EN 1706 alloy with 5 or 10.54 % of silica was the experimental material. The melted alloy was cast into "horizontal" three-channel mold to test its fluidity. The pouring temperatures were between 605 and 830 °C. In some cases, the experiment was not successful, for a some reasons. This fact led to a waste of time, energy, potential risk of accident, confusion among participants, especially "beginners" founders and became an impulse for the analysis of creation and possible events of fault for the fluidity test using the FTA. It has been found that for the probability of the top event in examined process was disproportionately high (0.29824. The Monte Carlo method was used for the simulation of the effect of decreasing the probability of basic events on the probability of the top event – the fault of the fluidity test.

  1. Design and test of 1/5th scale horizontal axis tidal current turbine

    Science.gov (United States)

    Liu, Hong-wei; Zhou, Hong-bin; Lin, Yong-gang; Li, Wei; Gu, Hai-gang

    2016-06-01

    Tidal current energy is prominent and renewable. Great progress has been made in the exploitation technology of tidal current energy all over the world in recent years, and the large scale device has become the trend of tidal current turbine (TCT) for its economies. Instead of the similarity to the wind turbine, the tidal turbine has the characteristics of high hydrodynamic efficiency, big thrust, reliable sealing system, tight power transmission structure, etc. In this paper, a 1/5th scale horizontal axis tidal current turbine has been designed, manufactured and tested before the full scale device design. Firstly, the three-blade horizontal axis rotor was designed based on traditional blade element momentum theory and its hydrodynamic performance was predicted in numerical model. Then the power train system and stand-alone electrical control unit of tidal current turbine, whose performances were accessed through the bench test carried out in workshop, were designed and presented. Finally, offshore tests were carried out and the power performance of the rotor was obtained and compared with the published literatures, and the results showed that the power coefficient was satisfactory, which agrees with the theoretical predictions.

  2. Horizontal Lang two-pencil test as a screening test for stereopsis and binocularity.

    Science.gov (United States)

    Nongpiur, Monisha E; Sharma, Pradeep

    2010-01-01

    To assess the horizontal Lang two-pencil test as a bedside test to detect gross stereopsis. Eighty-four strabismic subjects divided into two groups based on the amount of deviation, and 40 normal subjects were studied. Sensory status examination including binocularity and stereopsis were evaluated with Bagolini, Titmus test and The Netherlands organisation for applied scientific research (TNO), Randot, synoptophore and horizontal Lang two-pencil test. The subjects in the group with smaller deviation showed better performance on all the four stereo tests and over 90% demonstrated presence of fusion. When compared to TNO and Randot for determining presence of stereopsis, the horizontal Lang two-pencil test demonstrated sensitivity of 100% and 83.9%, specificity of 77.8% and 73.7%, and negative predictive value of 100% and 100% respectively. It also showed 100% specificity as a test for binocularity when compared with the Bagolini striated glass test. Horizontal Lang two-pencil test, an easily performed test with a high sensitivity and negative predictive value can be used as a screening test to detect gross stereopsis and binocularity.

  3. Enhanced boiling heat transfer in horizontal test bundles

    Energy Technology Data Exchange (ETDEWEB)

    Trewin, R.R.; Jensen, M.K.; Bergles, A.E.

    1994-08-01

    Two-phase flow boiling from bundles of horizontal tubes with smooth and enhanced surfaces has been investigated. Experiments were conducted in pure refrigerant R-113, pure R-11, and mixtures of R-11 and R-113 of approximately 25, 50, and 75% of R-113 by mass. Tests were conducted in two staggered tube bundles consisting of fifteen rows and five columns laid out in equilateral triangular arrays with pitch-to-diameter ratios of 1.17 and 1.5. The enhanced surfaces tested included a knurled surface (Wolverine`s Turbo-B) and a porous surface (Linde`s High Flux). Pool boiling tests were conducted for each surface so that reference values of the heat transfer coefficient could be obtained. Boiling heat transfer experiments in the tube bundles were conducted at pressures of 2 and 6 bar, heat flux values from 5 to 80 kW/m{sup 2}s, and qualities from 0% to 80%, Values of the heat transfer coefficients for the enhanced surfaces were significantly larger than for the smooth tubes and were comparable to the values obtained in pool boiling. It was found that the performance of the enhanced tubes could be predicted using the pool boiling results. The degradation in the smooth tube heat transfer coefficients obtained in fluid mixtures was found to depend on the difference between the molar concentration in the liquid and vapor.

  4. Method’s and Test Stand for Electronic PID Controller

    Directory of Open Access Journals (Sweden)

    Cristian Paul Chioncel

    2009-01-01

    Full Text Available The paper presents method’s and a testing stand for electronic controller using for this a signal generator and a digital oscilloscope respectively the virtual instrumentation and the signal acquisitions from the controllers input and output through an data acquisition board and an PC on that Lab View program runs.

  5. Design of a quadrotor flight test stand for system identification

    CSIR Research Space (South Africa)

    Beharie, MM

    2015-01-01

    Full Text Available This paper presents the design, development and construction of a flight test stand for a quadrotor UAV. As opposed to alternate forms of UAV, the power plant in the case of the quadrotor serves a dual purpose of control and propulsion. Since...

  6. Inflight exercise affects stand test responses after space flight

    Science.gov (United States)

    Lee, S. M.; Moore, A. D. Jr; Fritsch-Yelle, J. M.; Greenisen, M. C.; Schneider, S. M.

    1999-01-01

    PURPOSE: The purpose of this study was to determine whether exercise performed by Space Shuttle crew members during short-duration space flights (9-16 d) affects the heart rate (HR) and blood pressure (BP) responses to standing within 2-4 h of landing. METHODS: Thirty crew members performed self-selected inflight exercise and maintained exercise logs to monitor their exercise intensity and duration. Two subjects participated in this investigation during two different flights. A 10-min stand test, preceded by at least 6 min of quiet supine rest, was completed 10-15 d before launch (PRE) and within 4 h of landing (POST). Based upon their inflight exercise records, subjects were grouped as either high (HIex: > or = 3 times/week, HR > or = 70% HRmax, > or = 20 min/session, N = 11), medium (MEDex: > or = 3 times/week, HR or = 20 min/session, N = 10), or low (LOex: PRE differences between the groups in supine or standing HR and BP. Although POST supine HR was similar to PRE, all groups had an increased standing HR compared with PRE. The increase in HR upon standing was significantly greater after flight in the LOex group (36 +/- 5 bpm) compared with HIex or MEDex groups (25 +/- 1 bpm; 22 +/- 2 bpm). Similarly, the decrease in pulse pressure (PP) from supine to standing was unchanged after space flight in the MEDex and HIex groups but was significantly greater in the LOex group (PRE: -9 +/- 3; POST: -19 +/- 4 mm Hg). CONCLUSIONS: Thus, moderate to high levels of inflight exercise attenuated HR and PP responses to standing after space flight.

  7. Characteristic Value Method of Well Test Analysis for Horizontal Gas Well

    Directory of Open Access Journals (Sweden)

    Xiao-Ping Li

    2014-01-01

    Full Text Available This paper presents a study of characteristic value method of well test analysis for horizontal gas well. Owing to the complicated seepage flow mechanism in horizontal gas well and the difficulty in the analysis of transient pressure test data, this paper establishes the mathematical models of well test analysis for horizontal gas well with different inner and outer boundary conditions. On the basis of obtaining the solutions of the mathematical models, several type curves are plotted with Stehfest inversion algorithm. For gas reservoir with closed outer boundary in vertical direction and infinite outer boundary in horizontal direction, while considering the effect of wellbore storage and skin effect, the pseudopressure behavior of the horizontal gas well can manifest four characteristic periods: pure wellbore storage period, early vertical radial flow period, early linear flow period, and late horizontal pseudoradial flow period. For gas reservoir with closed outer boundary both in vertical and horizontal directions, the pseudopressure behavior of the horizontal gas well adds the pseudosteady state flow period which appears after the boundary response. For gas reservoir with closed outer boundary in vertical direction and constant pressure outer boundary in horizontal direction, the pseudopressure behavior of the horizontal gas well adds the steady state flow period which appears after the boundary response. According to the characteristic lines which are manifested by pseudopressure derivative curve of each flow period, formulas are developed to obtain horizontal permeability, vertical permeability, skin factor, reservoir pressure, and pore volume of the gas reservoir, and thus the characteristic value method of well test analysis for horizontal gas well is established. Finally, the example study verifies that the new method is reliable. Characteristic value method of well test analysis for horizontal gas well makes the well test analysis

  8. Cryogenic System for the Cryomodule Test Stand at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    White, Michael J. [Fermilab; Hansen, Benjamin [Fermilab; Klebaner, Arkadiy [Fermilab

    2017-10-09

    This paper describes the cryogenic system for the Cryomodule Test Stand (CMTS) at the new Cryomodule Test Facility (CMTF) located at Fermilab. CMTS is designed for production testing of the 1.3 GHz and 3.9GHz cryomodules to be used in the Linac Coherent Light Source II (LCLSII), which is an upgrade to an existing accelerator at Stanford Linear Accelerator Laboratory (SLAC). This paper will focus on the cryogenic system that extends from the helium refrigeration plant to the CMTS cave. Topics covered will include component design, installation and commissioning progress, and operational plans. The paper will conclude with a description of the heat load measurement plan.

  9. One-leg standing test for elderly populations.

    Science.gov (United States)

    Michikawa, Takehiro; Nishiwaki, Yuji; Takebayashi, Toru; Toyama, Yoshiaki

    2009-09-01

    The one-leg standing (OLS) test is one of the balance tests used to diagnose musculoskeletal ambulation disability symptom complex (MARS), a condition newly defined by three professional Japanese medical societies in 2006 to help identify the symptoms of motor organ deterioration and establish preventive strategies. Although many studies have used the OLS test, none has shown conclusively that the test can be used as a practical marker of frailty among elderly people, especially in community settings. Based on the type of epidemiological study -- i.e., descriptive epidemiology and analytical epidemiology (observational and intervention studies) -- we reviewed evidence on three fundamental issues related to the OLS test: (1) testing procedures and reference values; (2) the associations between the OLS time and negative events; (3) improvement of the OLS time by intervention. These issues are key to any discussion of whether the OLS test can be used as a practical marker for predicting frailty in community-dwelling elderly populations. Articles were collected from MEDLINE databases using the search terms "one- leg standing" and the other names included in the same category. Because various procedures are used to carry out the OLS test, the measured values for the OLS time varied widely from study to study. Some observational studies showed that the OLS time is related to negative events such as falls, declines in activity of daily living, and other morbidity. OLS times could be improved by several interventions. This review suggests that the OLS test can be a tool for predicting frailty in community-dwelling elderly populations. However, our review should be interpreted with caution because we did not confirm the evidence level of each of the studies we selected. Further research on this topic is needed.

  10. Cryomdoule Test Stand Reduced-Magnetic Support Design at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    McGee, Mike [Fermilab; Chandrasekaran, Saravan Kumar [Fermilab; Crawford, Anthony [Fermilab; Harms, Elvin [Fermilab; Leibfritz, Jerry [Fermilab; Wu, Genfa [Fermilab

    2016-06-01

    In a partnership with SLAC National Accelerator Laboratory (SLAC) and Jefferson Lab, Fermilab will assemble and test 17 of the 35 total 1.3 GHz cryomodules for the Linac Coherent Light Source II (LCLS-II) Project. These devices will be tested at Fermilab's Cryomodule Test Facility (CMTF) within the Cryomodule Test Stand (CMTS-1) cave. The problem of magnetic pollution became one of major issues during design stage of the LCLS-II cryomodule as the average quality factor of the accelerating cavities is specified to be 2.7 x 10¹⁰. One of the possible ways to mitigate the effect of stray magnetic fields and to keep it below the goal of 5 mGauss involves the application of low permeable materials. Initial permeability and magnetic measurement studies regarding the use of 316L stainless steel material indicated that cold work (machining) and heat affected zones from welding would be acceptable.

  11. The Cold Dark Matter Search test stand warm electronics card

    Energy Technology Data Exchange (ETDEWEB)

    Hines, Bruce; /Colorado U., Denver; Hansen, Sten; /Fermilab; Huber, Martin; /Colorado U., Denver; Kiper, Terry; /Fermilab; Rau, Wolfgang; /Queen' s U., Kingston; Saab, Tarek; /Florida U.; Seitz, Dennis; Sundqvist, Kyle; /UC, Berkeley; Mandic, Vuk; /Minnesota U.

    2010-11-01

    A card which does the signal processing for four SQUID amplifiers and two charge sensitive channels is described. The card performs the same functions as is presently done with two custom 9U x 280mm Eurocard modules, a commercial multi-channel VME digitizer, a PCI to GPIB interface, a PCI to VME interface and a custom built linear power supply. By integrating these functions onto a single card and using the power over Ethernet standard, the infrastructure requirements for instrumenting a Cold Dark Matter Search (CDMS) detector test stand are significantly reduced.

  12. Combined Experiment Phase 1. [Horizontal axis wind turbines: wind tunnel testing versus field testing

    Energy Technology Data Exchange (ETDEWEB)

    Butterfield, C.P.; Musial, W.P.; Simms, D.A.

    1992-10-01

    How does wind tunnel airfoil data differ from the airfoil performance on an operating horizontal axis wind turbine (HAWT) The National Renewable Energy laboratory has been conducting a comprehensive test program focused on answering this question and understanding the basic fluid mechanics of rotating HAWT stall aerodynamics. The basic approach was to instrument a wind rotor, using an airfoil that was well documented by wind tunnel tests, and measure operating pressure distributions on the rotating blade. Based an the integrated values of the pressure data, airfoil performance coefficients were obtained, and comparisons were made between the rotating data and the wind tunnel data. Care was taken to the aerodynamic and geometric differences between the rotating and the wind tunnel models. This is the first of two reports describing the Combined Experiment Program and its results. This Phase I report covers background information such as test setup and instrumentation. It also includes wind tunnel test results and roughness testing.

  13. HESTIA Commodities Exchange Pallet and Sounding Rocket Test Stand

    Science.gov (United States)

    Chaparro, Javier

    2013-01-01

    During my Spring 2016 internship, my two major contributions were the design of the Commodities Exchange Pallet and the design of a test stand for a 100 pounds-thrust sounding rocket. The Commodities Exchange Pallet is a prototype developed for the Human Exploration Spacecraft Testbed for Integration and Advancement (HESTIA) program. Under the HESTIA initiative the Commodities Exchange Pallet was developed as a method for demonstrating multi-system integration thru the transportation of In-Situ Resource Utilization produced oxygen and water to a human habitat. Ultimately, this prototype's performance will allow for future evaluation of integration, which may lead to the development of a flight capable pallet for future deep-space exploration missions. For HESTIA, my main task was to design the Commodities Exchange Pallet system to be used for completing an integration demonstration. Under the guidance of my mentor, I designed, both, the structural frame and fluid delivery system for the commodities pallet. The fluid delivery system includes a liquid-oxygen to gaseous-oxygen system, a water delivery system, and a carbon-dioxide compressors system. The structural frame is designed to meet safety and transportation requirements, as well as the ability to interface with the ER division's Portable Utility Pallet. The commodities pallet structure also includes independent instrumentation oxygen/water panels for operation and system monitoring. My major accomplishments for the commodities exchange pallet were the completion of the fluid delivery systems and the structural frame designs. In addition, parts selection was completed in order to expedite construction of the prototype, scheduled to begin in May of 2016. Once the commodities pallet is assembled and tested it is expected to complete a fully integrated transfer demonstration with the ISRU unit and the Environmental Control and Life Support System test chamber in September of 2016. In addition to the development of

  14. 3 MeV Test Stand commissioning report

    CERN Document Server

    Bellodi, Guilia; Andreassen, O; Comblin, J-F; Dimov, V; Lallement, J-B; Martin, C; Midttun, O; Ovalle, E; Raich, U; Roncarolo, F; Rossi, C; Scrivens, R; Vollaire, J; Yarmohammadi Satri, M; Zocca, Z

    2013-01-01

    Linac4 is a normal-conducting 160 MeV H- linear accelerator, presently under construction, that will replace the present 50 MeV Linac2 as injector of the CERN proton accelerator complex with the goal of increasing the LHC luminosity. The Linac4 front-end, composed of a 45 keV ion source, a Low Energy Beam Transport (LEBT), a 352.2 MHz Radio Frequency Quadrupole (RFQ) and a Medium Energy Beam Transport (MEBT) housing a beam chopper, was commissioned at the 3 MeV test stand area during the first half of 2013. This report gives details of the installation and operational systems used, describes the commissioning phases and measurements performed and summarizes the results that were finally achieved and the lessons learnt in the process.

  15. Horizontal, but not vertical canopy structure is related to stand functional diversity in a subtropical slope forest

    NARCIS (Netherlands)

    Lang, A.C.; Härdtle, W.; Bruelheide, H.; Kröber, W.; Schröter, M.; Wehrden, von H.; Oheimb, von G.

    2012-01-01

    The aim of this study was to analyse the relation of horizontal and vertical canopy structure to tree functional diversity of a highly diverse subtropical broad-leaved slope forest, stratified for different successional stages. This is of particular interest because many key ecosystem processes and

  16. One year update - Chevron's horizontal steam injection test facility

    Energy Technology Data Exchange (ETDEWEB)

    Sims, J.C.; Fram, J.H. [Chevron Energy Technology Company (Canada)

    2011-07-01

    In the heavy oil industry, control of the steam injection profile constitutes an important challenge when using a thermal recovery system in horizontal wells. In general, the measurement of two flow mixtures is complex and to date there is no reliable method for controlling two-phase steam distribution. The purpose of this paper is to provide an update on the results of testing flow splitting and liner isolation devices. These tests have been conducted by Chevron over the last year in a horizontal steam injection test facility built at the Kern River Field close to Bakersfield. This facility also allows Chevron to develop their own equipment for improving steam injection profile. Results show that none of the commercially available devices tested are able to provide consistent steam control. This paper highlighted the results of Chevron's horizontal steam injection test facility and the need for improvement of steam control equipment.

  17. Horizontal dual-point excitation and fatigue test of full-scale wind turbine blade

    Science.gov (United States)

    Pan, Zujin; Wu, Jianzhong; Zhao, Xinhua; Xie, Yan

    2017-06-01

    In order to meet the requirements of large-blade fatigue testing, a horizontal dual-point linear exciter loading program is developed. In this paper, Lagrange’s equation and FEM method are used to simulate the dual-point excitation theory model. The horizontal dual-point excitation characteristics of the blade are validated by the experimental method. The relationship among the dual-point exciting force, cycle time and bending moment during blade fatigue test in flap wise direction is studied. The advantages of horizontal dual-point excitation in blade fatigue test are analysed. Compared with vertical single-point excitation when the equal bending moment is reached, the exciting force and energy consumption required for dual-point excitation are reduced by 60.0% and 96.8%. Resonant frequency of the test system is improved by reducing the dead weight because of dual-point horizontal excitation. The entire blade fatigue test time is shortened by 7.4%. The use of horizontal dual-point excitation could save energy and shorten the entire fatigue test time.

  18. VALIDITY OF THE STANDING SPIKE TEST AS A MONITORING PROTOCOL FOR FEMALE VOLLEYBALL PLAYERS

    OpenAIRE

    Jose Manuel Palao; David Valades

    2012-01-01

    The purpose of this paper was: a) to provide reference values for the standing spike test for female volleyball players and b) to study whether the standing spike test is valid for assessing the theoretical differences between female volleyball players. The sample included 83 players from the first nine teams of the Spanish women's first volleyball division (52 Spanish players and 31 from other nationalities). The variables studied were the ball speed of the standing spike test, the age of th...

  19. Development of test stand for experimental investigation of chemical and physical phenomena in Liquid Rocket Engine

    Directory of Open Access Journals (Sweden)

    Emerson Andrade Santos

    2011-05-01

    Full Text Available The main objective of this work was to present the specification of an experimental firing test stand for liquid rocket engines (LRE and develop a program for control and acquisition of data. It provides conditions to test rocket engines with thrust from 50 to 100 kgf. A methodology for laboratory work implementation using information technology, which will allow the automatic and remote functioning of the test stand, permits users to input the necessary data to conduct tests safely, achieve accurate measurements and obtain reliable results. The control of propellant mass flow rates by pressure regulators and other system valves, as well as the test stand data acquisition, are carried out automatically through LabVIEW commercial software. The test stand program is a readable, scalable and maintainable code. The test stand design and its development represent the state of art of experimental apparatus in LRE testing.

  20. Well test analysis of horizontal wells in a two-layered reservoir ...

    African Journals Online (AJOL)

    In this paper, a well test analysis procedure is discussed for a two-layered oil reservoir drained from each layer by a horizontal well. Reservoir mathematical model are derived for each layer so that analysis can be done strictly for each layered reservoir. Procedures for obtaining all the directional permeabilities, wellbore ...

  1. Calibration of Virtual Testing Stand of the Car Cabin using climatic chamber tests

    Directory of Open Access Journals (Sweden)

    Pokorny Jan

    2015-01-01

    Full Text Available The aim of our research is to calibrate and verify of the software Virtual Testing Stand of the Car Cabin using climatic chamber tests. The Virtual Testing Stand is standalone executable software developed in Matlab for prediction of the cabin environment and thermal heat load by using the time-efficient heat balance model. The main limitation of the simulation method is a simplified convection scheme inside a cabin using the empirical correlations instead of the CFD simulations. In this paper we present the first preliminary tests of the calibration process and verification of the simulation results. Tests were carried out for the car Skoda Octavia Combi with the silver metallic paint. The material composition of the test car was deeply explored and the material properties of the cabin were identified as accurate as possible. The car was exposed to the various environments inside a climate chamber. In this paper we report about two performed tests: summer solar soak test and winter heat-up test with the defined heat source.

  2. Stability of the Horizontal Curvature of the LHC Cryodipoles During Cold Tests

    CERN Document Server

    Cano, E D Fernandez; García-Pérez, J; Jeanneret, Jean Bernard; Poncet, A; Seyvet, F; Tovar-Gonzalez, A; Wildner, E; IEEE Trans. Nucl. Sci.

    2006-01-01

    The LHC will be composed of 1232 horizontally curved, 15 meter long, superconducting dipole magnets cooled at 1.9 K. They are supported within their vacuum vessel by three Glass Fiber Reinforced Epoxy (GFRE) support posts. Each cryodipole is individually cold tested at CERN before its installation and interconnection in the LHC 27 km circumference tunnel. As the magnet geometry under cryogenic operation is extremely important for the LHC machine aperture, a new method has been developed at CERN in order to monitor the magnet curvature change between warm and cold states. It enabled us to conclude that there is no permanent horizontal curvature change of the LHC dipole magnet between warm and cold states, although a systematic horizontal transient deformation during cool-down was detected. This deformation generates loads in the dipole supporting system; further investigation permitted us to infer this behavior to the asymmetric thermal contraction of the rigid magnet thermal shield during cool-down. Controlli...

  3. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    Science.gov (United States)

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; Pbpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  4. Testing of a Stand for Analysis of Drilling Mud Friction Factor

    Directory of Open Access Journals (Sweden)

    Stanisław Stryczek

    2006-10-01

    Full Text Available A concept and realization of a universal laboratory stand for analyzing hydromechanical effects accompanying the drilling mud flow are presented in the paper. Requirements for basic technical subassemblies of the stand are defined. The principles of a flow meter, pressure converters and digital data readers are presented. Then a scheme of a laboratory stand, its principle and procedure are discussed. The process of stand testing through an empirical determination of the Faning friction factor for Newtonian fluids is presented and compared with literature data.

  5. Rapid HIV testing experience at Veterans Affairs North Texas Health Care System's Homeless Stand Downs.

    Science.gov (United States)

    Hooshyar, Dina; Surís, Alina M; Czarnogorski, Maggie; Lepage, James P; Bedimo, Roger; North, Carol S

    2014-01-01

    In the USA, 21% of the estimated 1.1 million people living with human immunodeficiency virus/acquired immune deficiency syndrome (HIV/AIDS) are unaware they are HIV-infected. In 2011, Veterans Health Administration (VHA)'s Office of Public Health in conjunction with VHA's Health Care for Homeless Veterans Program funded grants to support rapid HIV testing at homeless outreach events because homeless populations are more likely to obtain emergent rather than preventive care and have a higher HIV seroprevalence as compared to the general population. Because of a Veterans Affairs North Texas Health Care System (VANTHCS)'s laboratory testing requirement, VANTHCS partnered with community agencies to offer rapid HIV testing for the first time at VANTHCS' 2011 Homeless Stand Downs in Dallas, Fort Worth, and Texoma, Texas. Homeless Stand Downs are outreach events that connect Veterans with services. Veterans who declined testing were asked their reasons for declining. Comparisons by Homeless Stand Down site used Pearson χ², substituting Fisher's Exact tests for expected cell sizes Veterans attending the Homeless Stand Downs, 261 Veterans reported reasons for declining HIV testing, and 133 Veterans were tested, where 92% of the tested Veterans obtained their test results at the events - all tested negative. Veterans' reported reasons for declining HIV testing included previous negative result (n=168), no time to test (n=49), no risk factors (n=36), testing is not a priority (n=11), uninterested in knowing serostatus (n=6), and HIV-infected (n=3). Only "no time to test" differed significantly by Homeless Stand Down site. Nonresponse rate was 54%. Offering rapid HIV testing at Homeless Stand Downs is a promising testing venue since 15% of Veterans attending VANTHCS' Homeless Stand Downs were tested for HIV, and majority obtained their HIV test results at point-of-care while further research is needed to determine how to improve these rates.

  6. DEVELOPMENT OF AN ARMY STATIONARY AXLE TEST STAND FOR LUBRICANT EFFICIENCY EVALUATION-PART II

    Science.gov (United States)

    2017-01-13

    EFFICIENCY TEST STAND – PART II INTERIM REPORT TFLRF No. 484 by Adam C. Brandt Edwin A. Frame U.S. Army TARDEC Fuels and Lubricants...efficiency test stand to allow for laboratory based investigation of Fuel Efficient Gear Oils (FEGO) and their impact on vehicle efficiency. Development...differentiation of efficiency between tested lubricants was achieved in the low speed/lower load operating conditions of the FTM cycle , while efficiency

  7. Experience Operating an X-band High-Power Test Stand at CERN

    CERN Document Server

    Catalan-Lasheras, N; Doebert, S; Farabolini, W; Kovermann, J; McMonagle, G; Rey, S; Syratchev, I; Timeo, L; Wuensch, W; Woolley, B; Tagg, J

    2014-01-01

    CERN has constructed and is operating a klystron-based X-band test stand, called Xbox-1, dedicated to the high-gradient testing of prototype accelerating structures for CLIC and other applications such as FELs. The test stand has now been in operation for a year and significant progress has been made in understanding the system, improving its reliability, upgrading hardware and implementing automatic algorithms for conditioning the accelerating structures.

  8. Measurement and compensation of horizontal crabbing at the Cornell Electron Storage Ring Test Accelerator

    Directory of Open Access Journals (Sweden)

    M. P. Ehrlichman

    2014-04-01

    Full Text Available In storage rings, horizontal dispersion in the rf cavities introduces horizontal-longitudinal (xz coupling, contributing to beam tilt in the xz plane. This coupling can be characterized by a “crabbing” dispersion term ζ_{a} that appears in the normal mode decomposition of the 1-turn transfer matrix. ζ_{a} is proportional to the rf cavity voltage and the horizontal dispersion in the cavity. We report experiments at the Cornell Electron Storage Ring Test Accelerator where xz coupling was explored using three lattices with distinct crabbing properties. We characterize the xz coupling for each case by measuring the horizontal projection of the beam with a beam size monitor. The three lattice configurations correspond to (i 16 mrad xz tilt at the beam size monitor source point, (ii compensation of the ζ_{a} introduced by one of two pairs of rf cavities with the second, and (iii zero dispersion in rf cavities, eliminating ζ_{a} entirely. Additionally, intrabeam scattering is evident in our measurements of beam size vs rf voltage.

  9. Operational Performance of the Horizontal Fast Rise EMP Pulser at the Patuxent River EMP Test Facility

    Science.gov (United States)

    2011-06-01

    program. The facility utilized the hybrid elliptical horizontally polarized dipole antenna that was driven by the Maxwell Labs 5 MV (ML-5) dual...new pulser was delivered to Patuxent River October 1st, 2010, where it was re-assembled, installed, and tested in the HPD antenna by December 1st...Electromagnetic Pulse which radiates from its 150 Ohm biconical launch antenna1. A simplistic equivalent circuit model is shown in Figure 2. Each

  10. Vertical eye movements during horizontal head impulse test: a new clinical sign of superior vestibular neuritis

    OpenAIRE

    D'Onofrio, F

    2013-01-01

    SUMMARY In some patients suffering from acute unilateral peripheral vestibular deficit, the head impulse test performed towards the affected side reveals the typical catch-up saccade in the horizontal plane, and an oblique, mostly vertical, upward catch-up saccade after the rotation of the head towards the healthy side. Three cases are reported herein, which have been studied using slow motion video analysis of the eye movements captured by a high-speed webcam (90 fps). The clinical evidence ...

  11. Validity of the standing spike test as a monitoring protocol for female volleyball players.

    Science.gov (United States)

    Palao, J M; Valadés, D

    2012-12-01

    a) to provide reference values for the standing spike test for female volleyball players and b) to study whether the standing spike test is valid for assessing the theoretical differences between female volleyball players. The sample included 83 players from the first nine teams of the Spanish women's first volleyball division (52 Spanish players and 31 from other nationalities). The variables studied were the ball speed of the standing spike test, the age of the players, the player's role (outside hitter, opposite, middle-blocker, libero, or setter), height, and nationality of the players (Spanish or foreign). The results demonstrate the ranges for the standing spike among female performance volleyball players (70-82 km · h(-1)). The differences regarding nationality, player role, height, and age seem to indicate that the test is a valid instrument for monitoring the performance of female volleyball players.

  12. VALIDITY OF THE STANDING SPIKE TEST AS A MONITORING PROTOCOL FOR FEMALE VOLLEYBALL PLAYERS

    Directory of Open Access Journals (Sweden)

    Jose Manuel Palao

    2012-11-01

    Full Text Available The purpose of this paper was: a to provide reference values for the standing spike test for female volleyball players and b to study whether the standing spike test is valid for assessing the theoretical differences between female volleyball players. The sample included 83 players from the first nine teams of the Spanish women’s first volleyball division (52 Spanish players and 31 from other nationalities. The variables studied were the ball speed of the standing spike test, the age of the players, the player’s role (outside hitter, opposite, middle-blocker, libero, or setter, height, and nationality of the players (Spanish or foreign. The results demonstrate the ranges for the standing spike among female performance volleyball players (70-82 km · h-1. The differences regarding nationality, player role, height, and age seem to indicate that the test is a valid instrument for monitoring the performance of female volleyball players.

  13. Application of an In-Line Contamination Monitoring Unit to the AHT-64 Hydraulic Test Stand.

    Science.gov (United States)

    1981-06-04

    Specificat ion Ior ain In-1 ine Contaminat ion Monit (,r in I it ) J I roe-standing, two-wheel ed cart for the contaminit ion monitor; l)wov,.r, in, II...levels of vibration because it is a diesel-powered pomp utnit. Vibration tests of the AHT-64 indicate normal vibration amplitude to be 2 C ’it a critical...Commnd (NAVAIRSYSCOM) rejected the free-standing, two-wheeled cart concept proposed for the monitor and opted for an AHT-64 hydraulic test stand

  14. Reliability of Arm Curl and Chair Stand tests for assessing muscular endurance in older people

    Directory of Open Access Journals (Sweden)

    Boneth M

    2012-05-01

    Full Text Available Objective: to assess the test-retest reliability and level of agreement between measures of the 30 second (30-s Arm Curl and 30-s Chair Stand test in a sample of older adults from Bucaramanga. Materials and methods: a study of evaluation of diagnostic technology was done. Both tests were administered by the same evaluator to 111 adults older than 59 year-old (70,4 ± 7,3, on two occasions, with an interval of time between measures of 4 to 8 days. In the analysis, test-retest reliability was determined using the Intraclass Correlation Coefficient ICC= 2,1 with their confidence interval 95% (CI 95% respective. The agreement level was established by the Bland and Altman method. Results: the test-retest reproducibility of the 30-s Arm Curl test was very good ICC= 0,88 and to the Chair Stand test was good ICC= 0,78. The agreement was very good for both tests of muscle endurance. The CI 95% were between -3,8 and 3,2 stands to 30-s Chair Stand test and between -3,1 and 2,8 curls to 30-s Arm Curl test. Conclusion: the 30-s Arm Curl and 30-s Chair Stand test have good reliability and agreement to assess muscle endurance in older adults functionally independent.

  15. PROPOSAL FOR BUILD A TEST STAND TO THE STUDY WATER RAM BASED ON THE RECOMMENDATIONS CONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Dariusz GRYGO

    2016-05-01

    Full Text Available The main aim of this article was developed of a test stand to a study physics phenomena accruing at work in a ram water based on the construction recommendations. The experience gained by a number of attempts allowed to the developed construction recommendations that allowed to adjust the test stand to perform various studies of physics phenomena occurring at the work of water ram and easy adaptions to the new requirements. The article includes: the review of the test stands on which performed the study in the history and in the present times, description of the construction recommendations of the universal test stand and the proposal of the test stand developed based on the construction recommendations. Motivation to take up this issue follows from the interest of devices that work in an unconventional way, devices used a renewable energy that can be used in household e.g. to improve their energy balance, delivery water to houses, drinking water for animals, fields irrigation, etc. Analysis of the literature of the water ram, test stands and their performance shown that it is small and typically old development in popular science form. In times of intensive search new sources of renewable energy reactivation of this type equipment may be highly probable.

  16. PHYSICS RESULTS OF THE NSLS-II LINAC FRONT END TEST STAND

    Energy Technology Data Exchange (ETDEWEB)

    Fliller R. P.; Gao, F.; Yang, X.; Rose, J.; Shaftan, T.; Piel, C

    2012-05-20

    The Linac Front End Test Stand (LFETS) was installed at the Source Development Laboratory (SDL) in the fall of 2011 in order to test the Linac Front End. The goal of these tests was to test the electron source against the specifications of the linac. In this report, we discuss the results of these measurements and the effect on linac performance.

  17. Construction Progress of the S-IC Test Stand-Excavation

    Science.gov (United States)

    1961-01-01

    At its founding, the Marshall Space Flight Center (MSFC) inherited the Army's Jupiter and Redstone test stands, but much larger facilities were needed for the giant stages of the Saturn V. From 1960 to 1964, the existing stands were remodeled and a sizable new test area was developed. The new comprehensive test complex for propulsion and structural dynamics was unique within the nation and the free world, and they remain so today because they were constructed with foresight to meet the future as well as on going needs. Construction of the S-IC Static test stand complex began in 1961 in the west test area of MSFC, and was completed in 1964. The S-IC static test stand was designed to develop and test the 138-ft long and 33-ft diameter Saturn V S-IC first stage, or booster stage, weighing in at 280,000 pounds. Required to hold down the brute force of a 7,500,000-pound thrust produced by 5 F-1 engines, the S-IC static test stand was designed and constructed with the strength of hundreds of tons of steel and 12,000,000 pounds of cement, planted down to bedrock 40 feet below ground level. The foundation walls, constructed with concrete and steel, are 4 feet thick. The base structure consists of four towers with 40-foot-thick walls extending upward 144 feet above ground level. The structure was topped by a crane with a 135-foot boom. With the boom in the upright position, the stand was given an overall height of 405 feet, placing it among the highest structures in Alabama at the time. In this photo, taken July 13, 1961, progress is made with the excavation and preparation of the S-IC test stand site.

  18. Development and Performance Test of a Micro Horizontal Axis Wind Turbine Blade

    OpenAIRE

    Engr. Muhammad Shuwa,; Dr. Garba Mohammed Ngala

    2016-01-01

    This study describes the development and experimental studies performed to investigate the performance of a 1.5 m long Horizontal Axis Wind Turbine blade on a 4meter tower using 8o as an angle of attack. The blade was design using the Blade Element Momentum Theory (BEM), blade parameters such as the chord length, angle of attack, Tip Speed Ratio, Rotor diameter, Lift and Drag force were determined. The designed blade profile was developed and tested on an open field at Maidugur...

  19. Hip Strength Testing of Soccer Players With Long-Standing Hip and Groin Pain

    DEFF Research Database (Denmark)

    Rafn, Bolette S; Tang, Lars; Nielsen, Peter Martin

    2016-01-01

    OBJECTIVE: To investigate whether self-reported pain during hip strength testing correlates to a large degree with hip muscle strength in soccer players with long-standing unilateral hip and groin pain. DESIGN: Cross-sectional study. SETTING: Clinical assessments at Sports Orthopaedic Research...... strength (Spearman rho = -0.44, P = 0.016). CONCLUSIONS: Self-reported pain during testing does not seem to correlate with the majority of hip muscle strength tests used in soccer players with long-standing hip and groin pain....... Center-Copenhagen (SORC-C), Arthroscopic Centre Amager, Copenhagen University Hospital, Denmark. PARTICIPANTS: Twenty-four male soccer players with unilateral long-standing hip and groin pain. INTERVENTIONS: The soccer players performed 5 reliable hip muscle strength tests (isometric hip flexion...

  20. Integrated testing of standing balance and cognition: test-retest reliability and construct validity.

    Science.gov (United States)

    Szturm, Tony; Sakhalkar, Vedant; Boreskie, Sue; Marotta, Jonathan J; Wu, Christine; Kanitkar, Anuprita

    2015-01-01

    Balance and cognitive impairments which are common with aging often coexist, are prognostic of future adverse health events, including fall injuries. Consequently, dual-task assessment programs that simultaneously address both stability and cognition are important to consider in rehabilitation and benefit healthy aging. The objective of this study was to establish test-retest reliability and construct validity of a dual-task computer game-based platform (TGP) that integrates head tracking and cognitive tasks with balance activities. Thirty healthy, community-dwelling individuals median age 64 (range 60-67) were recruited from a certified Medical Fitness Facility. Participants performed a series of computerized head tracking and cognitive game tasks while standing on fixed and sponge surfaces. Testing was conducted on two occasions, one week apart. Moderate to high test retest reliability (ICC values of 0.55-0.75) was observed for all outcome measures representing balance, gaze performance, cognition, and dual-task performance. A significant increase in center of foot pressure (COP) excursion was observed during both head tracking and cognitive dual-task conditions. The results demonstrate the system's ability to reliably detect changes related to specific and integrated aspects of balance, gaze, and cognitive performance. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Development of a Modular Test Stand for the Measuring of Dynamic ...

    African Journals Online (AJOL)

    Calculations and dimension by means of CAD programs as well as results from early tests and both spatial and financial determining factors were integrated into the modularly planned and assembled test stand, which can be used for many different movements of the human body. In addition to the realized solution ...

  2. Ares Launch Vehicles Development Awakens Historic Test Stands at NASA's Marshall Space Flight Center

    Science.gov (United States)

    Dumbacher, Daniel L.; Burt, Richard K.

    2008-01-01

    This paper chronicles the rebirth of two national rocket testing assets located at NASA's Marshall Space Flight Center: the Dynamic Test Stand (also known as the Ground Vibration Test Stand) and the Static Test Stand (also known as the Main Propulsion Test Stand). It will touch on the historical significance of these special facilities, while introducing the requirements driving modifications for testing a new generation space transportation system, which is set to come on line after the Space Shuttle is retired in 2010. In many ways, America's journey to explore the Moon begins at the Marshall Center, which is developing the Ares I crew launch vehicle and the Ares V cargo launch vehicle, along with managing the Lunar Precursor Robotic Program and leading the Lunar Lander descent stage work, among other Constellation Program assignments. An important component of this work is housed in Marshall's Engineering Directorate, which manages more than 40 facilities capable of a full spectrum of rocket and space transportation technology testing - from small components to full-up engine systems. The engineers and technicians who operate these test facilities have more than a thousand years of combined experience in this highly specialized field. Marshall has one of the few government test groups in the United States with responsibility for the overall performance of a test program from conception to completion. The Test Laboratory has facilities dating back to the early 1960s, when the test stands needed for the Apollo Program and other scientific endeavors were commissioned and built along the Marshall Center's southern boundary, with logistics access by air, railroad, and barge or boat on the Tennessee River. NASA and its industry partners are designing and developing a new human-rated system based on the requirements for safe, reliable, and cost-effective transportation solutions. Given below are summaries of the Dynamic Test Stand and the Static Test Stand capabilities

  3. Effect of In-Flight Exercise and Extravehicular Activity on Postflight Stand Tests

    Science.gov (United States)

    Lee, Stuart M. C.; Moore, Alan D., Jr.; Fritsch-Yelle, Janice; Greenisen, Michael; Schneider, Suzanne M.; Foster, Philip P.

    2000-01-01

    The purpose of this study was to determine whether exercise performed by Space Shuttle crewmembers during short-duration spaceflights (9-16 days) affects the heart rate (HR) and blood pressure (BP) responses to standing within 2-4 hr of landing. Thirty crewmembers performed self-selected in-flight exercise and maintained exercise logs to monitor their exercise intensity and duration. A 10min stand test, preceded by at least 6 min of quiet supine rest, was completed 10- 15 d before launch (PRE) and within four hours of landing (POST). Based upon their in-flight exercise records, subjects were grouped as either high (HIex: = 3x/week, HR = 70% ,HRMax, = 20 min/session, n = 11), medium (MEDex: = 3x/week, HR = 70% HRmax, = 20 min/session, n = 10), or low (LOex: = 3x/week, HR and duration variable, n = 11) exercisers. HR and BP responses to standing were compared between groups (ANOVA, or analysis of variance, P PRE differences between the groups in supine or standing HR and BP. Although POST supine HR was similar to PRE, all groups had an increased standing HR compared to PRE. The increase in HR upon standing was significantly greater after flight in the LOex group (36+/-5 bpm) compared to HIex or MEDex groups (25+/-1bpm; 22+/-2 bpm). Similarly, the decrease in pulse pressure (PP) from supine to standing was unchanged after spaceflight in the MEDex and HIex groups, but was significantly less in the LOex group (PRE: -9+/- 3, POST: -19+/- 4 mmHg). Thus, moderate to high levels of in-flight exercise attenuated HR and PP responses to standing after spaceflight compared.

  4. Unified multifractal atmospheric dynamics tested in the tropics: part I, horizontal scaling and self criticality

    Directory of Open Access Journals (Sweden)

    Y. Chigirinskaya

    1994-01-01

    Full Text Available In this paper we test the Unified Mulifractal model of atmospheric dynamics in the tropics. In the first part, we empirically investigate the scaling behaviour along the horizontal, in the second part along the vertical. Here we concentrate on the presentation of basic multifractal notions and techniques and on how they give rise to self-organized critical structures. Indeed, we point out a rather simple and clear characterisation of these structures which may help to clarify both the nature of the oft-cited coherent structures and the generation of cyclones. Using 30 aircraft series of horizontal wind and temperature, we find rather remarkable constancy of the three universal multifractal indices H, C1 and α as well as the value of critical exponents qD, γD associated with multifractal phase transitions and self-organized critical structures. This constancy extends not only from wind tunnel and mid-latitude to the tropics, but also to multifractals generated by Navier-Stokes like equations.

  5. Mobile test stand for evaluation of electric power plants for unmanned aircraft

    Directory of Open Access Journals (Sweden)

    Serbezov Vladimir

    2017-01-01

    Full Text Available The absence of accurate performance data is a common problem with most civilian unmanned aerial vehicle (UAV power plant producers. The reasons for this are the small size of most of the manufacturers and the high price of precise wind tunnel testing and computer simulations. To overcome this problem at Dronamics Ltd., with support from the Department of Aeronautics of TU-Sofia, a mobile test stand for evaluation of electric power plants for unmanned aircraft was developed. The stand may be used statically, or may be installed on the roof of an automobile. The measurement system of the stand is based on popular hardware that is used in radio controlled models and in general automation. The verification of the measurement system is performed by comparing static test results with data published by the manufacturer of the tested electric motor. Tests were carried out with 2 different types of propellers and the results were compared with published results for common propellers as well as with results of theoretical studies. The results are satisfactory for practical applications. The use of this type of test stands can be a cheap and effective alternative for research and development start-up companies like Dronamics.

  6. Integrated System Health Management: Pilot Operational Implementation in a Rocket Engine Test Stand

    Science.gov (United States)

    Figueroa, Fernando; Schmalzel, John L.; Morris, Jonathan A.; Turowski, Mark P.; Franzl, Richard

    2010-01-01

    This paper describes a credible implementation of integrated system health management (ISHM) capability, as a pilot operational system. Important core elements that make possible fielding and evolution of ISHM capability have been validated in a rocket engine test stand, encompassing all phases of operation: stand-by, pre-test, test, and post-test. The core elements include an architecture (hardware/software) for ISHM, gateways for streaming real-time data from the data acquisition system into the ISHM system, automated configuration management employing transducer electronic data sheets (TEDS?s) adhering to the IEEE 1451.4 Standard for Smart Sensors and Actuators, broadcasting and capture of sensor measurements and health information adhering to the IEEE 1451.1 Standard for Smart Sensors and Actuators, user interfaces for management of redlines/bluelines, and establishment of a health assessment database system (HADS) and browser for extensive post-test analysis. The ISHM system was installed in the Test Control Room, where test operators were exposed to the capability. All functionalities of the pilot implementation were validated during testing and in post-test data streaming through the ISHM system. The implementation enabled significant improvements in awareness about the status of the test stand, and events and their causes/consequences. The architecture and software elements embody a systems engineering, knowledge-based approach; in conjunction with object-oriented environments. These qualities are permitting systematic augmentation of the capability and scaling to encompass other subsystems.

  7. An experimental test of the causes of forest growth decline with stand age.

    Science.gov (United States)

    Michael G. Ryan; Dan Binkley; James H. Fownes; Christian Giardina; Randy S. Senock

    2004-01-01

    The decline in aboveground wood production after canopy closure in even-aged forest stands is a common pattern in forests, but clear evidence for the mechanism causing the decline is lacking. The problem is fundamental to forest biology, commercial forestry (the decline sets the rotation age), and to carbon storage in forests. We tested three hypotheses...

  8. Validation Testing of Procedures for Determining the Performance of Stand-Alone Photovoltaic Systems

    Energy Technology Data Exchange (ETDEWEB)

    McNutt, P.; Kroposki, B.; Hansen, R.; DeBlasio, R.; Lynn, K.; Wilson, W.; Rosenthal, A.; Boulanger, P.

    2000-11-27

    Standard test procedures, ''IEEE P1526/D1 Draft Recommended Practice for Testing the Performance of Stand-Alone Photovoltaic Systems,'' [1] have been developed to assess the performance of stand-alone PV systems tested outdoors under prevailing conditions. A copy of the procedures is included in Appendix E. This report presents an overview of the procedures and results from three validation tests conducted between January 1999 and September 2000 at one European and four US test sites. There was good measurement agreement between the results measured at different test sites on similar systems. To date, most PV system performance test procedures have looked at the performance of the individual components and have not addressed how the integrated system works as a whole. The performance test procedures described in this report verify that the system and load operate as expected, ensure that the PV array and system are capable of recharging the battery, determine the usable battery capacity (UBC), and determine if there is any significant change in the UBC measured three different times during the procedures. The procedures have been submitted to both IEEE SCC21 and IEC TC82 for use in developing standards. The IEEE SCC21 has initiated P1526, ''Recommended Practice for Testing the Performance of Stand-Alone Photovoltaic Systems,'' [1] and the IEC TC82 has initiated Standard 62124, ''Photovoltaic Stand-Alone Systems Design Qualification and Type Approval'' [2]. The IEC document also addresses indoor testing.

  9. Development and testing of vortex generators for small horizontal axis wind turbines

    Science.gov (United States)

    Gyatt, G. W.

    1986-01-01

    Vortex generators (VGs) for a small (32 ft diameter) horizontal axis wind turbine, the Carter Model 25, have been developed and tested. Arrays of VGs in a counterrotating arrangement were tested on the inbound half-span, outboard half-span, and on the entire blade. VG pairs had their centerlines spaced at a distance of 15% of blade chord, with a spanwise width of 10% of blade chord. Each VG had a length/height ratio of 4, with a height of between 0.5% and 1.0% of the blade chord. Tests were made with roughness strips to determine whether VGs alleviated the sensitivity of some turbines to an accumulation of bugs and dirt on the leading edge. Field test data showed that VGs increased power output up to 20% at wind speeds above 10 m/s with only a small (less than 4%) performance penalty at lower speeds. The VGs on the outboard span of the blade were more effective than those on inner sections. For the case of full span coverage, the energy yearly output increased almost 6% at a site with a mean wind speed of 16 mph. The VGs did reduce the performance loss caused by leading edge roughness. An increase in blade pitch angle has an effect on the power curve similar to the addition of VGs. VGs alleviate the sensitivity of wind turbine rotors to leading edge roughness caused by bugs and drift.

  10. Measurement properties and feasibility of clinical tests to assess sit-to-stand/stand-to-sit tasks in subjects with neurological disease: a systematic review

    Directory of Open Access Journals (Sweden)

    Paula F. S. Silva

    2014-04-01

    Full Text Available BACKGROUND: Subjects with neurological disease (ND usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. OBJECTIVE: To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. METHOD: A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. RESULTS: Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99 for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99 for stroke and inter-rater reliability (ICC=0.99 for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77, and the feasibility and safety were good for subjects with Alzheimer's disease. CONCLUSIONS: The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement

  11. Modeling the Test-Retest Statistics of a Localization Experiment in the Full Horizontal Plane.

    Science.gov (United States)

    Morsnowski, André; Maune, Steffen

    2016-10-01

    Two approaches to model the test-retest statistics of a localization experiment basing on Gaussian distribution and on surrogate data are introduced. Their efficiency is investigated using different measures describing directional hearing ability. A localization experiment in the full horizontal plane is a challenging task for hearing impaired patients. In clinical routine, we use this experiment to evaluate the progress of our cochlear implant (CI) recipients. Listening and time effort limit the reproducibility. The localization experiment consists of a 12 loudspeaker circle, placed in an anechoic room, a "camera silens". In darkness, HSM sentences are presented at 65 dB pseudo-erratically from all 12 directions with five repetitions. This experiment is modeled by a set of Gaussian distributions with different standard deviations added to a perfect estimator, as well as by surrogate data. Five repetitions per direction are used to produce surrogate data distributions for the sensation directions. To investigate the statistics, we retrospectively use the data of 33 CI patients with 92 pairs of test-retest-measurements from the same day. The first model does not take inversions into account, (i.e., permutations of the direction from back to front and vice versa are not considered), although they are common for hearing impaired persons particularly in the rear hemisphere. The second model considers these inversions but does not work with all measures. The introduced models successfully describe test-retest statistics of directional hearing. However, since their applications on the investigated measures perform differently no general recommendation can be provided. The presented test-retest statistics enable pair test comparisons for localization experiments.

  12. Test re-test reliability of centre of pressure measures during standing balance in individuals with knee osteoarthritis.

    Science.gov (United States)

    Takacs, Judit; Carpenter, Mark G; Garland, S Jayne; Hunt, Michael A

    2014-01-01

    Assessment of changes in standing balance following an intervention requires accurate measurement of balance parameters. The reliability of centre of pressure measures of balance during single-leg standing has not been reported in individuals with knee osteoarthritis. The purpose of this study was to assess the test re-test reliability of force platform centre of pressure measures during single-leg standing in older adults with knee osteoarthritis. Twenty-five adults with radiographic evidence of knee osteoarthritis performed single-leg standing balance trials on a laboratory-grade force platform on two occasions, no more than 14 days apart. Participants were asked to stand on their more symptomatic limb for three, ten second trials. Centre of pressure measures collected included: standard deviation in the mediolateral and anteroposterior directions, mean path length, velocity, and area. The mean of the three trials was calculated. Intraclass correlation coefficients, standard error of measurement, Bland and Altman plots and the minimum detectable change were calculated. Intraclass correlation coefficients ranged from 0.54 to 0.87, suggesting mixed reliability of measures. Reliability was lowest for the centre of pressure area (intraclass correlation coefficient=0.54), and highest for centre of pressure velocity and path length (intraclass correlation coefficient=0.87 for both). Standard error of measurement values were low for standard deviation in the mediolateral direction and high for centre of pressure area. These results suggest that centre of pressure values, in particular path length and velocity, are appropriate for assessment of standing balance in people with medial knee osteoarthritis. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Constraints on helium enhancement in the globular cluster M4 (NGC 6121): The horizontal branch test

    Energy Technology Data Exchange (ETDEWEB)

    Valcarce, A. A. R.; De Medeiros, J. R. [Universidade Federal do Rio Grande do Norte, Departamento de Física, 59072-970 Natal, RN (Brazil); Catelan, M. [Pontificia Universidad Católica de Chile, Centro de Astroingeniería, Av. Vicuña Mackena 4860, 782-0436 Macul, Santiago (Chile); Alonso-García, J. [Pontificia Universidad Católica de Chile, Instituto de Astrofísica, Facultad de Física, Av. Vicuña Mackena 4860, 782-0436 Macul, Santiago (Chile); Cortés, C. [Universidad Metropolitana de Ciencias de la Educación, Facultad de Ciencias Básicas, Departamento de Física, Av. José Pedro Alessandri 774, Santiago (Chile)

    2014-02-20

    Recent pieces of evidence have revealed that most, and possibly all, globular star clusters are composed of groups of stars that formed in multiple episodes with different chemical compositions. In this sense, it has also been argued that variations in the initial helium abundance (Y) from one population to the next are also the rule, rather than the exception. In the case of the metal-intermediate globular cluster M4 (NGC 6121), recent high-resolution spectroscopic observations of blue horizontal branch (HB) stars (i.e., HB stars hotter than the RR Lyrae instability strip) suggest that a large fraction of blue HB stars are second-generation stars formed with high helium abundances. In this paper, we test this scenario by using recent photometric and spectroscopic data together with theoretical evolutionary computations for different Y values. Comparing the photometric data with the theoretically derived color-magnitude diagrams, we find that the bulk of the blue HB stars in M4 have ΔY ≲ 0.01 with respect to the cluster's red HB stars (i.e., HB stars cooler than the RR Lyrae strip)—a result which is corroborated by comparison with spectroscopically derived gravities and temperatures, which also favor little He enhancement. However, the possible existence of a minority population on the blue HB of the cluster with a significant He enhancement level is also discussed.

  14. Calibration method accelerometers unit of inertial navigation system on test stand

    Directory of Open Access Journals (Sweden)

    Htun Naing Myint

    2014-01-01

    Full Text Available The article described a technique for calibrating accelerometers unit on special test stands. The developed method allows to the determining the bias accelerometers unit, errors of scale factors accelerometers unit and angles of non-orthogonal accelerometers unit without presenting stringent requirements for high-precision testing equipment. Obtained by measuring the provisions of a test bed to which you want to set a block of accelerometers to obtain estimates of the instrumental errors of the block accelerometers. However, that requires precise measurement outputs of the accelerometers.

  15. Effect of yoga training on one leg standing and functional reach tests in obese individuals with poor postural control.

    Science.gov (United States)

    Jorrakate, Chaiyong; Kongsuk, Jutaluk; Pongduang, Chiraprapa; Sadsee, Boontiwa; Chanthorn, Phatchari

    2015-01-01

    [Purpose] The aim of the present study was to investigate the effect of yoga training on static and dynamic standing balance in obese individuals with poor standing balance. [Subjects and Methods] Sixteen obese volunteers were randomly assigned into yoga and control groups. The yoga training program was performed for 45 minutes per day, 3 times per week, for 4 weeks. Static and dynamic balance were assessed in volunteers with one leg standing and functional reach tests. Outcome measures were tested before training and after a single week of training. Two-way repeated measure analysis of variance with Tukey's honestly significant difference post hoc statistics was used to analyze the data. [Results] Obese individuals showed significantly increased static standing balance in the yoga training group, but there was no significant improvement of static or dynamic standing balance in the control group after 4 weeks. In the yoga group, significant increases in static standing balance was found after the 2nd, 3rd, and 4th weeks. Compared with the control group, static standing balance in the yoga group was significantly different after the 2nd week, and dynamic standing balance was significantly different after the 4th week. [Conclusion] Yoga training would be beneficial for improving standing balance in obese individuals with poor standing balance.

  16. Modeling and analysis of horizontal structure of a mixed tree stands (on example of sample plots in the «Bastak» nature reserve in the Middle Amur river area

    Directory of Open Access Journals (Sweden)

    A. N. Kolobov

    2015-06-01

    Full Text Available The results of the research model and real data spatial distribution of trees in single-species, ages and mixed stands are studied. Modeling of the horizontal structure of the stand was based on a computer simulation model. Investigation of the horizontal structure of the stand allows drawing of conclusions about the processes of intraspecific and interspecific competition. It is shown that the model used to generate spatial data model reflects the basic mechanisms of stacked-mosaic structure of the stand, which is observed in natural communities. It allows future use of this model to study the characteristics of the formation of the spatial structure of mixed forest communities, developing under the influence of internal (competition and external (logging, windfalls, herbivores, etc. factors. Statistical analysis of the tree spatial distribution for shade-tolerant and light-loving species relative to each other showed that, on average, around an arbitrarily chosen shade-tolerant tree species, there is an area within which the opportunity to meet the tree light-loving species is less than it would be under their random placement. Around an arbitrarily chosen «large» tree of shade-tolerant species there is an area within which the opportunity to meet the «small» or «medium» light-loving tree species is less than would have been at their random placement. It is shown that the mutual arrangement of «large» light-loving trees and «small», «medium» shade-tolerant trees is no different from a random allocation. As a result of competitive processes of spatial arrangement for light-loving tree species is determined by the placement of shade-tolerant trees. Location of light-loving trees does not affect the location of shade-tolerant trees. The relative placement of different types of shade-tolerant trees, especially spruce, fir and pine, are independent of each other.

  17. Evaluation of Modulus of Elasticity in Standing Trees and Sawn Wood in Populous deltoids using Nondestructive Stress Wave Testing

    OpenAIRE

    Mehrab Madhoushi; Soheila Daneshvar

    2014-01-01

    The aim of this paper was to evaluate relationship between dynamic modulus of elasticity (MOEd) in healthy standing trees of Populus deltoides and static modulus of elasticity (MOEs) of sawn lumber from the same standing trees, using nondestructive stress wave testing (NDT). For this purpose, NDT stress wave technique was used. The study was performed on 10 healthy standing trees of Populus deltoides. The diameter of trees at the breast height was selected at two categories, namely 25-30 cm a...

  18. THE COMPLEX OF STANDS FOR TESTING THE AIR CUSHION CHASSIS OF AIRCRAFT AND VEHICLES

    Directory of Open Access Journals (Sweden)

    2016-01-01

    Full Text Available This article deals with a set of stands made in NIMK TSAGI for testing and creating the air cushion chassis for the aircraft and vehicles. It allows to fully embrace the process of developing and constructing the air cushion chassis for air- craft and solve problems relating to peculiarities of such aircraft on the takeoff, landing and movement in the elementary prepared and unprepared soil runways, flat terrain and water areas. The complex includes: the experimental installation to study aeroelasticity phenomena of the chassis in the extending and retracting process with simulation of aircraft and ekran- oplane takeoff and landing modes in the air flow, including the wind tunnels; the experimental stand with vertical screen for testing of ekranoplane models in T-5 wind tunnel of NIMC TsAGI, permitting to simultaneously vary the model’s posi- tion relatively to the screen, roll, pitch (angle of attack, and banking; mobile experimental stand with contact crawler gear, for experimental determination and comparative evaluation of the chassis with different patterns of formation and air cush- ion fences for all-year-round testing in natural conditions at elementary-prepared and unprepared sites and water areas. Based on mathematical simulation of flow past in the wind tunnel the possibility of use booth stand with vertical screen and experimental installation to study aeroelasticity phenomena of the chassis for experimental studies, respectively, by defini- tion of the aerodynamic characteristics of forces and moments of the air cushion aircraft and ekranoplanes models and the research of phenomena of aeroelasticity of flexible fencing is substantiated.

  19. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    Science.gov (United States)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  20. Influence of eye closing on the cardiovascular response to stand test on stable and unstable platforms.

    Science.gov (United States)

    Arbeille, Ph; Kerbeci, P; Besnard, S; Montoya, A; Dupui, P

    2004-07-01

    Check if the stimulation of the leg muscles and neuro-sensorial system during stand test influence the cardiovascular response to stand test pre and post a 7 d HDT (4 subjects). After 20 min supine, the subject stood for 10 min, and closed the eyes for 1 min. Then he stayed 2 min stand up on ant-posterior or lateral unstable platform and closed the eyes for 30 sec. The cerebral and lower limb flow were assessed by Doppler (skin fixed sensors) and also the cerebral to femoral flow ratio (CFR). All 4 subjects were tolerant, CFR increased similarly pre and post HDT. Post HDT eye closing increased leg muscle activity, and femoral flow increased more than pre HDT, on ant-post unstable platform. The trace of the body foot pressure point was much longer post HDT on the ant-post platform. Post HDT neuro-sensorial disadaptation may contribute to reduce the orthostatic tolerance at least in absence of visual references.

  1. Insensitivity of the "Romberg test of standing balance on firm and compliant support surfaces" to the results of caloric and VEMP tests.

    Science.gov (United States)

    Jacobson, Gary P; McCaslin, Devin L; Piker, Erin G; Gruenwald, Jill; Grantham, Sarah; Tegel, Lauren

    2011-01-01

    The objective of this study was to assess the sensitivity, specificity, and positive and negative predictive value of the Romberg Test of Standing Balance on Firm and Compliant Support Surfaces (RTSBFCSS) for the identification of patients with vestibular system impairments affecting the horizontal semicircular canal, saccule, and/or inferior and superior vestibular nerves. The RTSBFCSS was developed for the National Health and Nutrition Examination Survey (NHANES) and was used recently to estimate the numbers of individuals aged 40 yr or older with vestibular system impairments among the general population of the United States. A retrospective analysis of the medical records of 103 consecutive patients aged 40 yr or older (mean age 59 ± 12 yr, 71 females) who had undergone vestibular assessment at the Balance Disorders Clinic at the Vanderbilt University School of Medicine. Patients with complete electro- or videonystagmography testing, cervical vestibular evoked myogenic potential (cVEMP) testing, and the RTSBFCSS screening test were included in the analysis. A series of 2 × 2 tables were created that represented the number of "true positives," "true negatives," "false positives," and "false negatives" of the RTSBFCSS under conditions where the caloric test was abnormal and then separately where the cVEMP test was abnormal. The data were analyzed in a manner such that sensitivity, specificity, and both positive and negative predictive value of the RTSBFCSS could be calculated. When the caloric test was used as the criterion standard and the subject selection criteria in the NHANES study were used (i.e., subjects who were able to maintain postural stability for trials 1-3 of the RTSBFCSS; N = 45), the sensitivity and specificity of the RTSBFCSS to impairment of the horizontal semicircular canal or superior vestibular nerve were 55% and 64%, respectively, yielding positive and negative predictive values of 55% and 64%, respectively. When all patients aged 40 yr

  2. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Mirarchi, D.; Redaelli, S.; Scandale, W. [CERN, European Organization for Nuclear Research, Geneva 23 (Switzerland); Hall, G. [Imperial College, Blackett Laboratory, London (United Kingdom)

    2017-06-15

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going. (orig.)

  3. Application of the Life Safety Code to a Historic Test Stand

    Science.gov (United States)

    Askins, Bruce; Lemke, Paul R.; Lewis, William L.; Covell, Carol C.

    2011-01-01

    NASA has conducted a study to assess alternatives to refurbishing existing launch vehicle modal test facilities as opposed to developing new test facilities to meet the demands of a very fiscally constrained test and evaluation environment. The results of this study showed that Marshall Space Flight Center (MSFC) Test Stand (TS) 4550 could be made compliant, within reasonable cost and schedule impacts, if safety processes and operational limitations were put in place to meet the safety codes and concerns of the Fire Marshall. Trades were performed with key selection criteria to ensure that appropriate levels of occupant safety are incorporated into test facility design modifications. In preparation for the ground vibration tests that were to be performed on the Ares I launch vehicle, the Ares Flight and Integrated Test Office (FITO) organization evaluated the available test facility options, which included the existing mothballed structural dynamic TS4550 used by Apollo and Shuttle, alternative ground vibration test facilities at other locations, and construction of a new dynamic test stand. After an exhaustive assessment of the alternatives, the results favored modifying the TS4550 because it was the lowest cost option and presented the least schedule risk to the NASA Constellation Program for Ares Integrated Vehicle Ground Vibration Test (IVGVT). As the renovation design plans and drawings were being developed for TS4550, a safety concern was discovered the original design for the construction of the test stand, originally built for the Apollo Program and renovated for the Shuttle Program, was completed before NASA s adoption of the currently imposed safety and building codes per National Fire Protection Association Life Safety Code [NFPA 101] and International Building Codes. The initial FITO assessment of the design changes, required to make TS4550 compliant with current safety and building standards, identified a significant cost increase and schedule impact

  4. Standard test method for measuring rolling friction characteristics of a spherical shape on a flat horizontal plane

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers the use of an angled launch ramp to initiate rolling of a sphere or nearly spherical shape on a flat horizontal surface to determine the rolling friction characteristics of a given spherical shape on a given surface. 1.1.1 Steel balls on a surface plate were used in interlaboratory tests (see Appendix X1). Golf balls on a green, soccer and lacrosse balls on playing surfaces, bowling balls on an a lane, basketballs on hardwood, and marbles on composite surface were tested in the development of this test method, but the test applies to any sphere rolling on any flat horizontal surface. 1.1.2 The rolling friction of spheres on horizontal surfaces is affected by the spherical shape’s stiffness, radius of curvature, surface texture, films on the surface, the nature of the counterface surface; there are many factors to consider. This test method takes all of these factors into consideration. The spherical shape of interest is rolled on the surface of interest using a standard ramp to...

  5. Tests of the Empirical Classification of Horizontal and Vertical Intra-industry Trade

    DEFF Research Database (Denmark)

    Lüthje, Teit; Nielsen, Jørgen Ulff-Møller

    2002-01-01

    Using longitudinal data this paper shows the separation of international trade in (a) inter-industry trade, (b) horizontal intra-industry trade, and (c) vertical intra-industry trade used in the empirical trade literature to be non-stable at the individual product level. The high level of vertica...

  6. Green Propellant Test Capabilities of the Altitude Combustion Stand at the NASA Glenn Research Center

    Science.gov (United States)

    Kubiak, Jonathan M.; Arnett, Lori A.

    2016-01-01

    The NASA Glenn Research Center (GRC) is committed to providing simulated altitude rocket test capabilities to NASA programs, other government agencies, private industry partners, and academic partners. A primary facility to support those needs is the Altitude Combustion Stand (ACS). ACS provides the capability to test combustion components at a simulated altitude up to 100,000 ft. (approx.0.2 psia/10 Torr) through a nitrogen-driven ejector system. The facility is equipped with an axial thrust stand, gaseous and cryogenic liquid propellant feed systems, data acquisition system with up to 1000 Hz recording, and automated facility control system. Propellant capabilities include gaseous and liquid hydrogen, gaseous and liquid oxygen, and liquid methane. A water-cooled diffuser, exhaust spray cooling chamber, and multi-stage ejector systems can enable run times up to 180 seconds to 16 minutes. The system can accommodate engines up to 2000-lbf thrust, liquid propellant supply pressures up to 1800 psia, and test at the component level. Engines can also be fired at sea level if needed. The NASA GRC is in the process of modifying ACS capabilities to enable the testing of green propellant (GP) thrusters and components. Green propellants are actively being explored throughout government and industry as a non-toxic replacement to hydrazine monopropellants for applications such as reaction control systems or small spacecraft main propulsion systems. These propellants offer increased performance and cost savings over hydrazine. The modification of ACS is intended to enable testing of a wide range of green propellant engines for research and qualification-like testing applications. Once complete, ACS will have the capability to test green propellant engines up to 880 N in thrust, thermally condition the green propellants, provide test durations up to 60 minutes depending on thrust class, provide high speed control and data acquisition, as well as provide advanced imaging and

  7. THE 30-S CHAIR STAND TEST AND HABITUAL MOBILITY PREDICT REHABILITATION NEEDS AFTER ACUTE ADMISSION

    DEFF Research Database (Denmark)

    Hansen Bruun, Inge; Nørgaard, Birgitte; Maribo, Thomas

    2016-01-01

    Introduction: One month after admission to emergency department (ED) a fifth of the elderly patients have a low physical ability and therefore a need for rehabilitation. Early identification of these patients is difficult and has so far been based on self-reported information, a challenge...... as elderly might be confused or unrealistic about their physical abilities. The 30-s Chair Stand Test (30s-CST) has not been validated in ED, but is used at community level for this purpose. The De Morton Mobility Index (DEMMI) has been validated for acute patients. Our study evaluated if a 30s-CST-score ≤8...... with habitual mobility....

  8. Is stand-alone D-dimer testing safe to rule out acute pulmonary embolism?

    Science.gov (United States)

    van Es, N; van der Hulle, T; Büller, H R; Klok, F A; Huisman, M V; Galipienzo, J; Di Nisio, M

    2017-02-01

    Essentials A stand-alone D-dimer below 750 μg/L has been proposed to rule out acute pulmonary embolism (PE). This was a post-hoc analysis on data from 6 studies comprising 7268 patients with suspected PE. The negative predictive value of a D-dimer pulmonary embolism (PE), without additional imaging, but this approach needs validation. Objectives To evaluate stand-alone D-dimer testing at a positivity threshold of 750 μg L-1 to rule out PE. Methods Individual data from 7268 patients with suspected PE previously enrolled in six prospective management studies were used. Patients were assessed by the Wells rule followed by quantitative D-dimer testing in those with a 'PE unlikely' score. Patients were classified post hoc as having a negative (< 750 μg L-1 ) or positive (≥ 750 μg L-1 ) D-dimer. Using a one-stage meta-analytic approach, the negative predictive value (NPV) of stand-alone D-dimer testing was evaluated overall and in different risk subgroups. Results The pooled incidence of PE was 23% (range, 13-42%). Overall, 44% of patients had a D-dimer < 750 μg L-1 , of whom 2.8% were diagnosed with PE at baseline or during 3-month follow-up (NPV, 97.2%; 95% confidence interval [CI], 94.9-98.5). The NPV was highest in patients with a low probability of PE according to the Wells rule (99.2%; 95% CI, 98.6-99.5%) and lowest in those with a high probability of PE (79.3%; 95% CI, 53.0-92.8%). The NPVs in patients with active cancer, patients with previous venous thromboembolism and inpatients were 96.2% (95% CI, 85.6-99.1%), 94.7% (95% CI, 88.6-97.6%) and 92.7% (95% CI, 79.3-97.7%), respectively. Conclusions Our findings suggest that stand-alone D-dimer testing at a positivity threshold of 750 μg L-1 is not safe to rule out acute PE. © 2016 International Society on Thrombosis and Haemostasis.

  9. Design of the NSLS-II Linac Front End Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Fliller III, R.; Johanson, M.; Lucas, M.; Rose, J.; Shaftan, T.

    2011-03-28

    The NSLS-II operational parameters place very stringent requirements on the injection system. Among these are the charge per bunch train at low emittance that is required from the linac along with the uniformity of the charge per bunch along the train. The NSLS-II linac is a 200 MeV linac produced by Research Instruments Gmbh. Part of the strategy for understanding to operation of the injectors is to test the front end of the linac prior to its installation in the facility. The linac front end consists of a 100 kV electron gun, 500 MHz subharmonic prebuncher, focusing solenoids and a suite of diagnostics. The diagnostics in the front end need to be supplemented with an additional suite of diagnostics to fully characterize the beam. In this paper we discuss the design of a test stand to measure the various properties of the beam generated from this section. In particular, the test stand will measure the charge, transverse emittance, energy, energy spread, and bunching performance of the linac front end under all operating conditions of the front end.

  10. Prototypes and system test stands for the Phase1 upgrade of the CMS pixel detector

    CERN Document Server

    AUTHOR|(CDS)2073564

    2015-01-01

    The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/17. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line as the trigger rate increase. This increase is due to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was conf...

  11. TDLAS Test-stand Diagnostics Development for Velocity, Temperature, Efficiency, and Erosion for Space Shuttle Main Engines Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose here to develop tunable diode laser spectroscopy as a diagnostic for the Space Shuttle main engines during test stand operations. These engines represent...

  12. Observation of a H- Beam at the CERN Linac 4 Test Stand using a Pepper-pot

    CERN Document Server

    Delerue, N; Midttun, O; Scrivens, R; Tsesmelis, E

    2010-01-01

    Pepper-pot based transverse emittance measurement has the advantage of providing a fast (single shot) measurement with a relatively simple hardware. We report on the installation of a pepper-pot at the CERN Linac 4 test stand.

  13. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults

    NARCIS (Netherlands)

    Regterschot, G. Ruben H.; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and

  14. Field evaluation of a horizontal well recirculation system for groundwater treatment: Pilot test at the Clean Test Site Portsmouth Gaseous Diffusion Plant, Piketon, Ohio

    Energy Technology Data Exchange (ETDEWEB)

    Muck, M.T.; Kearl, P.M.; Siegrist, R.L. [and others

    1998-08-01

    This report presents the results of field testing a horizontal well recirculation system at the Portsmouth Gaseous Diffusion Plant (PORTS). The recirculation system uses a pair of horizontal wells, one for groundwater extraction and treatment and the other for reinjection of treated groundwater, to set up a recirculation flow field. The induced flow field from the injection well to the extraction well establishes a sweeping action for the removal and treatment of groundwater contaminants. The overall purpose of this project is to study treatment of mixed groundwater contaminants that occur in a thin water-bearing zone not easily targeted by traditional vertical wells. The project involves several research elements, including treatment-process evaluation, hydrodynamic flow and transport modeling, pilot testing at an uncontaminated site, and pilot testing at a contaminated site. The results of the pilot test at an uncontaminated site, the Clean Test Site (CTS), are presented in this report.

  15. Universal computer test stand (recommended computer test requirements). [for space shuttle computer evaluation

    Science.gov (United States)

    1973-01-01

    Techniques are considered which would be used to characterize areospace computers with the space shuttle application as end usage. The system level digital problems which have been encountered and documented are surveyed. From the large cross section of tests, an optimum set is recommended that has a high probability of discovering documented system level digital problems within laboratory environments. Defined is a baseline hardware, software system which is required as a laboratory tool to test aerospace computers. Hardware and software baselines and additions necessary to interface the UTE to aerospace computers for test purposes are outlined.

  16. Comparison between Standing Broad Jump test and Wingate test for assessing lower limb anaerobic power in elite sportsmen.

    Science.gov (United States)

    Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P

    2017-04-01

    Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power (r = 0.446, p Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.

  17. Integrated System Health Management (ISHM) for Test Stand and J-2X Engine: Core Implementation

    Science.gov (United States)

    Figueroa, Jorge F.; Schmalzel, John L.; Aguilar, Robert; Shwabacher, Mark; Morris, Jon

    2008-01-01

    ISHM capability enables a system to detect anomalies, determine causes and effects, predict future anomalies, and provides an integrated awareness of the health of the system to users (operators, customers, management, etc.). NASA Stennis Space Center, NASA Ames Research Center, and Pratt & Whitney Rocketdyne have implemented a core ISHM capability that encompasses the A1 Test Stand and the J-2X Engine. The implementation incorporates all aspects of ISHM; from anomaly detection (e.g. leaks) to root-cause-analysis based on failure mode and effects analysis (FMEA), to a user interface for an integrated visualization of the health of the system (Test Stand and Engine). The implementation provides a low functional capability level (FCL) in that it is populated with few algorithms and approaches for anomaly detection, and root-cause trees from a limited FMEA effort. However, it is a demonstration of a credible ISHM capability, and it is inherently designed for continuous and systematic augmentation of the capability. The ISHM capability is grounded on an integrating software environment used to create an ISHM model of the system. The ISHM model follows an object-oriented approach: includes all elements of the system (from schematics) and provides for compartmentalized storage of information associated with each element. For instance, a sensor object contains a transducer electronic data sheet (TEDS) with information that might be used by algorithms and approaches for anomaly detection, diagnostics, etc. Similarly, a component, such as a tank, contains a Component Electronic Data Sheet (CEDS). Each element also includes a Health Electronic Data Sheet (HEDS) that contains health-related information such as anomalies and health state. Some practical aspects of the implementation include: (1) near real-time data flow from the test stand data acquisition system through the ISHM model, for near real-time detection of anomalies and diagnostics, (2) insertion of the J-2X

  18. Impact of Acoustic Standing Waves on Structural Responses: Reverberant Acoustic Testing (RAT) vs. Direct Field Acoustic Testing (DFAT)

    Science.gov (United States)

    Kolaini, Ali R.; Doty, Benjamin; Chang, Zensheu

    2012-01-01

    Loudspeakers have been used for acoustic qualification of spacecraft, reflectors, solar panels, and other acoustically responsive structures for more than a decade. Limited measurements from some of the recent speaker tests used to qualify flight hardware have indicated significant spatial variation of the acoustic field within the test volume. Also structural responses have been reported to differ when similar tests were performed using reverberant chambers. To address the impact of non-uniform acoustic field on structural responses, a series of acoustic tests were performed using a flat panel and a 3-ft cylinder exposed to the field controlled by speakers and repeated in a reverberant chamber. The speaker testing was performed using multi-input-single-output (MISO) and multi-input-multi-output (MIMO) control schemes with and without the test articles. In this paper the spatial variation of the acoustic field due to acoustic standing waves and their impacts on the structural responses in RAT and DFAT (both using MISO and MIMO controls for DFAT) are discussed in some detail.

  19. Numerical modeling of a 2K J-T heat exchanger used in Fermilab Vertical Test Stand VTS-1

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Prabhat Kumar [Raja Ramanna Centre for Advanced Technology (RRCAT), Indore (MP), India; Rabehl, Roger [FNAL

    2014-07-01

    Fermilab Vertical Test Stand-1 (VTS-1) is in operation since 2007 for testing the superconducting RF cavities at 2 K. This test stand has single layer coiled finned tubes heat exchanger before J-T valve. A finite difference based thermal model has been developed in Engineering Equation Solver (EES) to study its thermal performance during filling and refilling to maintain the constant liquid level of test stand. The model is also useful to predict its performance under other various operating conditions and will be useful to design the similar kind of heat exchanger for future needs. Present paper discusses the different operational modes of this heat exchanger and its thermal characteristics under these operational modes. Results of this model have also been compared with the experimental data gathered from the VTS-1 heat exchanger and they are in good agreement with the present model.

  20. Evolutionary emergence and maintenance of horizontally transmitted mutualism that do not rely on the supply of standing variation in symbiont quality.

    Science.gov (United States)

    Uchiumi, Y; Ohtsuki, H; Sasaki, A

    2017-12-01

    Mutualism based on reciprocal exchange of costly services must avoid exploitation by 'free-rides'. Accordingly, hosts discriminate against free-riding symbionts in many mutualistic relationships. However, as the selective advantage of discriminators comes from the presence of variability in symbiont quality that they eliminate, discrimination and thus mutualism have been considered to be maintained with exogenous supply of free-riders. In this study, we tried to resolve the 'paradoxical' co-evolution of discrimination by hosts and cooperation by symbionts, by comparing two different types of discrimination: 'one-shot' discrimination, where a host does not reacquire new symbionts after evicting free-riders, and 'resampling' discrimination, where a host does from the environment. Our study shows that this apparently minor difference in discrimination types leads to qualitatively different evolutionary outcomes. First, although it has been usually considered that the benefit of discriminators is derived from the variability of symbiont quality, the benefit of a certain type of discriminators (e.g. one-shot discrimination) is proportional to the frequency of free-riders, which is in stark contrast to the case of resampling discrimination. As a result, one-shot discriminators can invade the free-rider/nondiscriminator population, even if standing variation for symbiont quality is absent. Second, our one-shot discriminators can also be maintained without exogenous supply of free-riders and hence is free from the paradox of discrimination. Therefore, our result indicates that the paradox is not a common feature of evolution of discrimination but is a problem of specific types of discrimination. © 2017 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2017 European Society For Evolutionary Biology.

  1. Evaluation of Modulus of Elasticity in Standing Trees and Sawn Wood in Populous deltoids using Nondestructive Stress Wave Testing

    Directory of Open Access Journals (Sweden)

    Mehrab Madhoushi

    2014-05-01

    Full Text Available The aim of this paper was to evaluate relationship between dynamic modulus of elasticity (MOEd in healthy standing trees of Populus deltoides and static modulus of elasticity (MOEs of sawn lumber from the same standing trees, using nondestructive stress wave testing (NDT. For this purpose, NDT stress wave technique was used. The study was performed on 10 healthy standing trees of Populus deltoides. The diameter of trees at the breast height was selected at two categories, namely 25-30 cm and 30-35 cm. Measurement of wave velocity in standing trees were done transversely in radial direction at two geographical directions as North-South and East-West at the breast height, namely 130 cm and longitudinal measurements were done on the height between 80 and 180 cm. Then, standing trees were cut following by measurements of wave velocity in their logs. Logs were kept for two months after cutting in order to reduce moisture content. Then, they were cut into the clear specimens for statistical bending test and their MOE were evaluated according to ASTM standard. The results showed that the stress wave velocity and dynamic modulus of elasticity in longitudinal direction of standing trees and logs were more than those in transverse directions. Also, stress wave velocity and dynamic modulus of elasticity of the logs were higher than those in their standing trees at both directions. Finally, regression analysis indicated that the correlation coefficient between MOEd in standing trees and logs at diameter 30-35 cm is (r= 0.94, which is statistically significant.

  2. Observer report about field tests with a FALCON 4G stand-off detector by SEC Technologies

    NARCIS (Netherlands)

    Meer, J.A. van der; Nieuwenhuizen, M.S.

    2016-01-01

    Field testing of the large distance stand-off CB detector FALCON 4G by SEC Technologies in Lipovsky Mikulas (Slovakia) was observed by 2 employees of TNO on 28 and 29 September 2016. Based on the experimental set-up as well as the execution by SEC Technologies TNO observed the tests employing the

  3. Profile and Emittance Measurements at the CERN LINAC4 3 MeV test Stand

    CERN Document Server

    Zocca, F; Duraffourg, M; Focker, GJ; Gerard, D; Raich, U; Roncarolo, F

    2013-01-01

    A new 160 MeV H- Linac named Linac-4 will be built at CERN to replace the old 50 MeV proton Linac. The ion source, the 3 MeV Radio Frequency Quadrupole (RFQ) and the Medium Energy Beam Transport (MEBT) line hosting a chopper, have been commissioned in a dedicated test stand. Wire grids and wire scanners were used to measure the transverse beam profile and a slit/grid emittance meter was installed on a temporary test bench plugged at the RFQ and MEBT exit in different stages. The emittance meter slit was also used as a scanning scraper able to reconstruct the transverse profile by measuring the transmission with a downstream current transformer. On the same measurement bench, a spectrometer in conjunction with a wire grid allowed measuring the energy spread of the particles. This paper summarizes the measurement results that allowed characterizing the 3 MeV beam and discusses the present understanding of monitor performance.

  4. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Research of explosives in an environment of high pressure and temperature using a new test stand

    Directory of Open Access Journals (Sweden)

    Jan Drzewiecki

    2015-01-01

    Full Text Available In this article the test stand for determining the blast abilities of explosives in high pressure and temperature conditions as well as the initial results of the research are presented. Explosives are used in rock burst and methane prevention to destroy precisely defined fragments of the rock mass where energy and methane are accumulated. Using this preventive method for fracturing the structure of the rocks which accumulate the energy or coal of the methane seam very often does not bring the anticipated results. It is because of the short range of destructive action of the post-blast gases around the blast hole. Evaluation of the blast dynamics of explosives in a test chamber, i.e. in the pressure and temperature conditions comparable to those found “in situ”, will enable evaluation of their real usefulness in commonly used mining hazard preventive methods. At the same time, it will enable the development of new designs of the explosive charges used for precisely determined mining hazards. In order to test the explosives for their use in difficult environmental conditions and to determine the characteristics of their explosion, a test chamber has been built. It is equipped with a system of sensors and a high-frequency recording system of pressure and temperature during a controlled explosion of an explosive charge. The results of the research will enable the development of new technologies for rock burst and methane prevention which will significantly increase workplace health and safety level. This paper presented results constitute the initial phase of research started in the middle of 2014.

  6. Which is preferable for orthostatic hypotension diagnosis in older adults: active standing test or head-up tilt table test?

    Science.gov (United States)

    Aydin, Ali Ekrem; Soysal, Pinar; Isik, Ahmet Turan

    2017-01-01

    Correct evaluation of orthostatic hypotension (OH) is crucial in geriatric practice, since OH is associated with mortality and morbidity. The study aimed to determine the most appropriate method for measuring blood pressure in transition from supine to upright position in order to diagnose OH in older adults. Active standing test (AST) and head-up tilt table (HUT) test as well as comprehensive geriatric assessment (CGA), including mini-mental state examination or the cognitive state test, mini-nutritional assessment, basic and instrumental activities of daily living, and Tinetti performance-oriented mobility assessment indexes, were performed in 290 geriatric patients. The prevalence of OH during HUT and AST was 19% and 37%, respectively. In patients with OH during HUT, the frequency of dementia and recurrent falls were higher (P0.05). Comparison of the groups according to CGA measurements revealed significant differences in terms of cognition, nutritional status, activities of daily life, and balance function in patients with OH only during HUT (P0.05). The sensitivity, specificity, positive predictive value, and negative predictive values of AST were 49.0%, 65.5%, 25.0%, and 84.6% respectively, according to HUT. The results suggest that orthostatic blood pressure changes determined by HUT might be of higher clinical significance than that by AST in older adults. It might be important that the evaluation of OH by HUT should be included in daily geriatric practice.

  7. Which is preferable for orthostatic hypotension diagnosis in older adults: active standing test or head-up tilt table test?

    Directory of Open Access Journals (Sweden)

    Aydin AE

    2017-01-01

    Full Text Available Ali Ekrem Aydin,1 Pinar Soysal,2 Ahmet Turan Isik1 1Center for Aging Brain and Dementia, Department of Geriatric Medicine, Faculty of Medicine, Dokuz Eylul University, Izmir, Turkey; 2Kayseri Education and Research Hospital, Geriatric Center, Kayseri, Turkey Background: Correct evaluation of orthostatic hypotension (OH is crucial in geriatric practice, since OH is associated with mortality and morbidity. The study aimed to determine the most appropriate method for measuring blood pressure in transition from supine to upright position in order to diagnose OH in older adults.Methods: Active standing test (AST and head-up tilt table (HUT test as well as comprehensive geriatric assessment (CGA, including mini-mental state examination or the cognitive state test, mini-nutritional assessment, basic and instrumental activities of daily living, and Tinetti performance-oriented mobility assessment indexes, were performed in 290 geriatric patients.Results: The prevalence of OH during HUT and AST was 19% and 37%, respectively. In patients with OH during HUT, the frequency of dementia and recurrent falls were higher (P<0.05; on the other hand, the levels of serum vitamin D and albumin and estimated glomerular filtration rate were lower (P<0.05. However, all these parameters for OH during AST were not significant (P>0.05. Comparison of the groups according to CGA measurements revealed significant differences in terms of cognition, nutritional status, activities of daily life, and balance function in patients with OH only during HUT (P<0.05, but not during AST (P>0.05. The sensitivity, specificity, positive predictive value, and negative predictive values of AST were 49.0%, 65.5%, 25.0%, and 84.6% respectively, according to HUT.Conclusion: The results suggest that orthostatic blood pressure changes determined by HUT might be of higher clinical significance than that by AST in older adults. It might be important that the evaluation of OH by HUT should be

  8. Effect of posterior tibial tendon dysfunction on unipedal standing balance test.

    Science.gov (United States)

    Kulig, Kornelia; Lee, Szu-Ping; Reischl, Stephen F; Noceti-DeWit, Lisa

    2015-01-01

    Foot pain and diminished functional capacity are characteristics of tibialis posterior tendon dysfunction (TPTD). This study tested the hypotheses that women with TPTD would have impaired performance of a unipedal standing balance test (USBT) and that balance performance would be related to the number of single limb heel raises (SLHR). Thirty-nine middle-aged women, 19 with early stage TPTD (stage I and II), were instructed to perform 2 tasks; a USBT and repeated SLHR. Balance success was defined as a 10-second stance. For those who were successful, center of pressure (COP) data in anterior-posterior (AP) and medial-lateral (ML) directions were recorded as a measure of postural sway. SLHR performance was divided into 3 bins (≤2; 3-9 and > 10 repetitions). The between-balance success on performing the SLHR test was analyzed using the Fisher's exact test (2 × 3). Independent t tests were used to compare between-group differences in postural sway. Relationship of postural sway to the number of heel raises was assessed using Spearman's rho. The success rate of the USBT was significantly lower in women with TPTD than the controls (47% vs 85%, P = .041). In addition, women with TPTD who completed the USBT exhibited increased AP COP displacement (14.0 ± 7.4 vs 8.4 ± 1.3 mm, P = .008), and a strong trend of increased ML COP displacement (8.3 ± 4.5 vs 6.1 ± 1.2 mm, P = .050). The success rate of USBT was correlated with the number of SLHR (P = .01). The AP and ML COP displacement were correlated with SLHR (r = -.538 and .495), respectively. Women with TPTD have difficulty in performing the USBT. Performance of the USBT and SLHR are highly correlated and predictive of each other. A unipedal balance test may be used as a proxy TPTD assessment tool to the heel raising test when pain prevents performance. Level III, case control study. © The Author(s) 2014.

  9. Value of the "Standing Test" in the Diagnosis and Evaluation of Beta-blocker Therapy Response in Long QT Syndrome.

    Science.gov (United States)

    Muñoz-Esparza, Carmen; Zorio, Esther; Domingo Valero, Diana; Peñafiel-Verdú, Pablo; Sánchez-Muñoz, Juan J; García-Molina, Esperanza; Sabater, María; Navarro, Marina; San-Román, Irene; Pérez, Inmaculada; Santos, Juan J; Cabañas-Perianes, Valentín; Valdés, Mariano; Pascual, Domingo; García-Alberola, Arcadio; Gimeno Blanes, Juan R

    2017-11-01

    Patients with congenital long QT syndrome (LQTS) have an abnormal QT adaptation to sudden changes in heart rate provoked by standing. The present study sought to evaluate the standing test in a cohort of LQTS patients and to assess if this QT maladaptation phenomenon is ameliorated by beta-blocker therapy. Electrographic assessments were performed at baseline and immediately after standing in 36 LQTS patients (6 LQT1 [17%], 20 LQT2 [56%], 3 LQT7 [8%], 7 unidentified-genotype patients [19%]) and 41 controls. The corrected QT interval (QTc) was measured at baseline (QTcsupine) and immediately after standing (QTcstanding); the QTc change from baseline (ΔQTc) was calculated as QTcstanding - QTcsupine. The test was repeated in 26 patients receiving beta-blocker therapy. Both QTcstanding and ΔQTc were significantly higher in the LQTS group than in controls (QTcstanding, 528 ± 46ms vs 420 ± 15ms, P Beta-blockers attenuated the response to standing in LQTS patients (QTcstanding, 440 ± 32ms, P beta-blocker therapy in LQTS patients. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Preliminary experimental results of tungsten wire-array Z-pinches on primary test stand

    Science.gov (United States)

    Huang, Xian-Bin; Zhou, Shao-Tong; Dan, Jia-Kun; Ren, Xiao-Dong; Wang, Kun-Lun; Zhang, Si-Qun; Li, Jing; Xu, Qiang; Cai, Hong-Chun; Duan, Shu-Chao; Ouyang, Kai; Chen, Guang-Hua; Ji, Ce; Wei, Bing; Feng, Shu-Ping; Wang, Meng; Xie, Wei-Ping; Deng, Jian-Jun; Zhou, Xiu-Wen; Yang, Yi

    2015-07-01

    The Primary Test Stand (PTS) developed at the China Academy of Engineering Physics is a 20 TW pulsed power driver, which can deliver a ˜10 MA, 70 ns rise-time (10%-90%) current to a short-circuit load and has important applications in Z-pinch driven inertial confinement fusion and high energy density physics. Preliminary results of tungsten wire-array Z-pinch experiments on PTS are presented. The load geometries investigated include 15-mm-tall cylindrical single and nested arrays with diameter ranging from 13 mm to 30 mm, consisting of 132-300 tungsten wires with 5-10 μm in diameter. Multiple diagnostics were fielded to characterize the x-ray radiation from wire-array Z pinches. The x-ray peak power (˜50 TW) and total radiated energy (˜500 kJ) were obtained from a single 20-mm-diam array with 80-ns stagnation time. The highest x-ray peak power up to 80 TW with 2.4 ns FWHM was achieved by using a nested array with 20-mm outer diameter, and the total x-ray energy from the nested array is comparable to that of single array. Implosion velocity estimated from the time-resolved image measurement exceeds 30 cm/μs. The detailed experimental results and other findings are presented and discussed.

  11. Commissioning of the Linac4 RFQ at the 3 MeV test stand

    CERN Document Server

    Rossi, C; Bellodi, G; Broere, J; Brunner, O; Lombardi, A M; Balula, J M; Yanez, P M; Noirjean, J; Pasquino, C; Raich, U; Roncarolo, F; Vretenar, M; Desmons, M; France, A; Piquet, O

    2013-01-01

    Linac4, the future 160 MeV Hˉ injector to the CERN Proton Synchrotron Booster, is presently under construction at CERN as a first step of the planned upgrade of the LHC injectors. The low energy section of LINAC4, consisting of an ion source, a 352.2 MHz Radio Frequency Quadrupole (RFQ) and a chopper line is being commissioned in a dedicated test stand before installation in its final position in the tunnel. The RFQ is designed to accelerate a 45 keV, 70 mA, Hˉ beam to 3 MeV, with an efficiency of 95% while preserving the transverse emittance. The RFQ, a four-vane structure 3 m in length, has been designed in collaboration with CEA/IRFU and is has been fabricated at the CERN workshop. The precise fabrication has allowed achieving a field flatness of 1%. The completion of the accelerating structure in September 2012 was followed by a complete series of bead-pull measurements and by high-power conditioning to the nominal power of 0.39 MW corresponding to a voltage of 78 kV across the 3 meters. Measurements wi...

  12. Method for experimental investigation of transient operation on Laval test stand for model size turbines

    Science.gov (United States)

    Fraser, R.; Coulaud, M.; Aeschlimann, V.; Lemay, J.; Deschenes, C.

    2016-11-01

    With the growing proportion of inconstant energy source as wind and solar, hydroelectricity becomes a first class source of peak energy in order to regularize the grid. The important increase of start - stop cycles may then cause a premature ageing of runners by both a higher number of cycles in stress fluctuations and by reaching a higher stress level in absolute. Aiming to sustain good quality development on fully homologous scale model turbines, the Hydraulic Machines Laboratory (LAMH) of Laval University has developed a methodology to operate model size turbines on transient regimes such as start-up, stop or load rejection on its test stand. This methodology allows maintaining a constant head while the wicket gates are opening or closing in a representative speed on the model scale of what is made on the prototype. This paper first presents the opening speed on model based on dimensionless numbers, the methodology itself and its application. Then both its limitation and the first results using a bulb turbine are detailed.

  13. Modelling evapotranspiration at three boreal forest stands using the CLASS: tests of parameterizations for canopy conductance and soil evaporation

    Science.gov (United States)

    Bartlett, Paul A.; McCaughey, J. Harry; Lafleur, Peter M.; Verseghy, Diana L.

    2003-03-01

    The performance of the Canadian Land Surface Scheme (CLASS) was evaluated in off-line runs, using data collected at three boreal forest stands located near Thompson, Manitoba: young jack pine, mature jack pine, and mature black spruce. The data were collected in the late spring through autumn of 1994 and 1996, as part of the Boreal Ecosystem-Atmosphere Study (BOREAS).The diurnal range in modelled soil heat flux was exaggerated at all sites. Soil evaporation was modelled poorly at the jack pine stands, with overestimation common and a step change to low evaporation as the soil dried. Replacing the soil evaporation algorithm, which was based on the estimation of a surface relative humidity value, with one based on soil moisture in the top soil layer reduced the overestimation and eliminated the step changes. Modelled water movement between soil layers was too slow at the jack pine stands. Modifying the soil hydraulic parameters to match an observed characteristic curve at the young jack pine stand produced a soil water suction that agreed more closely with measurements and improved drainage between soil layers.The latent heat flux was overestimated and the sensible heat flux underestimated at all three stands. New Jarvis-Stewart-type canopy conductance algorithms were developed from stomatal conductance measurements. At the jack pine stands, stomatal conductance scaled by leaf area index reproduced canopy conductance, but a reduction in the scaled stomatal conductance by one half was necessary at the black spruce stand, indicating a nonlinearity in the scaling of stomatal conductance for this ecosystem. The root-mean-squared error for daily average latent heat flux for the control run of the CLASS and for the best test run are 49 W m-2 and 14 W m-2 respectively at the young jack pine stand, 50 W m-2 and 15 W m-2 respectively at the old jack pine stand, and 48 W m-2 and 13 W m-2 respectively at the old black spruce stand.

  14. Optimization of the stand for test of hybrid rocket engines of solid fuel

    Directory of Open Access Journals (Sweden)

    Zolotorev Nikolay

    2017-01-01

    Full Text Available In the paper the laboratory experimental stand of the hybrid rocket engine of solid fuel to study ballistic parameters of the engine at burning of high-energy materials in flow of hot gas is presented. Mixture of air with nitrogen with a specified content of active oxygen is used as a gaseous oxidizer. The experimental stand has modular design and consists of system of gas supply, system of heating of gas, system for monitoring gas parameters, to which a load cell with a model engine was connected. The modular design of the stand allows to change its configuration under specific objective. This experimental stand allows to conduct a wide range of the pilot studies at interaction of a hot stream of gas with samples high-energy materials.

  15. Versatile Horizontal Force Probe for Mechanical Tests on Pipette-Held Cells, Particles, and Membrane Capsules

    National Research Council Canada - National Science Library

    Ounkomol, Chawin; Xie, Hongtao; Dayton, Paul A; Heinrich, Volkmar

    2009-01-01

    .... Pipette-held test objects are translated perpendicularly to and from the stationary cantilever, eliminating the need to attach them to a carrier surface and substantially reducing unwanted hydrodynamic coupling effects...

  16. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke

    DEFF Research Database (Denmark)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla

    2016-01-01

    OBJECTIVE: The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability...... of both tests in patients admitted to an acute stroke unit. METHODS: Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error...... with corresponding SRD values of 3. CONCLUSION: Excellent reliability was observed for the timed 'Up & Go' test and the '30second Chair-Stand' test in hospitalised stroke patients. The thresholds to detect a real change in performance were 18.7% for the timed 'Up & Go' test and 2.0 repetitions for the '30second...

  17. Standing cough test for evaluation of post-prostatectomy incontinence: a pilot study.

    Science.gov (United States)

    Morey, Allen F; Singla, Nirmish; Carmel, Maude; Klein, Alexandra; Tausch, Timothy J; Siegel, Jordan; Tachibana, Isamu; Scott, Jeremy

    2017-02-01

    We implemented a standardized Standing Cough Test (SCT) for assessment of men with post-prostatectomy incontinence (PPI) and stratified results according to an objective clinical grading scale in an attempt to facilitate male anti-incontinence surgical procedure selection. SCT was routinely performed during the initial outpatient consultation for PPI. Incontinence severity was recorded based on a novel Male Stress Incontinence Grading Scale (MSIGS) to stratify PPI. Each patient was assigned an incontinence grade score of 0 through 4 during the SCT. Men with mild stress urinary incontinence (SUI) (grades 0-2) were offered sling surgery while those with heavier SUI (grades 3-4) were offered artificial urinary sphincter (AUS). MSIGS grade was correlated to preoperative patient-reported pads per day (PPD), and patient-reported outcomes of anti-incontinence surgery were assessed. Among 62 consecutive PPI patients, 20 (32%) were graded as mild based on SCT, while the majority (42/62, 68%) were graded as moderate-severe. Average time from prostatectomy to treatment was 6 years. MSIGS grade demonstrated a strong correlation with preoperative PPD (r = 0.74). Among the 53 patients who underwent surgery for PPI, 14 with mild SUI received a sling, while 39 (74%) more severe cases received an AUS. Patient-reported improvement was high overall in both groups (median 95%). Most men with chronic PPI present for definitive treatment in a delayed manner after prostatectomy despite having severe incontinence. The SCT provides immediate, objective information about the severity of PPI which strongly correlates with patient-reported pads-per-day and may expedite anti-incontinence surgical procedure selection.

  18. Reliability and Validity of Standing Back Extension Test for Detecting Motor Control Impairment in Subjects with Low Back Pain.

    Science.gov (United States)

    Gondhalekar, Gauri A; Kumar, Senthil P; Eapen, Charu; Mahale, Ajit

    2016-01-01

    Low back pain is a chronic health problem with high socioeconomic impact. Specific diagnosis or treatment approach has not yet effectively established to treat chronic low back pain. Standing Back Extension Test is one of the clinical measures to detect the passive extension subgroup of Motor Control Impairment (MCI); which could have an impact on spinal stability leading to recurrent chronic low back pain. Reliability and validity of this test is not fully established. To determine the intra-rater and inter-rater reliability and concurrent validity of the Standing Back Extension Test for detecting MCI of the lumbar spine. A total of 50 subjects were included in the study, 25 patients with Non Specific Low Back Pain (NSLBP) (12 men, 13 women) and 25 healthy controls (12 men, 13 women) were recruited into the study. All subjects performed the test movement. Two raters blinded to the subjects rated the test performance as either 'Positive' or 'Negative' based on the predetermined rating protocol. The thickness of Transverse Abdominis (TrA) muscle was assessed using Rehabilitative Ultrasound Imaging (RUSI). For reliability, the kappa coefficient with percent agreement was calculated and for assessing the validity Receiver Operator Characteristic (ROC) curves and Area under the Curve (AUC) were constructed. The standing back extension test showed very good intra-rater (k=0.87 with an agreement of 96%) and good inter-rater (k=0.78 with an agreement of 94%) reliability and high AUC for TrA muscle. The standing back extension test was found to be a reliable and a valid measure to detect passive extension subgroup for MCI in subjects with low back pain.

  19. HTGR core model response to simultaneous horizontal and vertical excitations

    Energy Technology Data Exchange (ETDEWEB)

    Bezler, P.; Curreri, J.R.

    1978-01-01

    An experimental program was undertaken to investigate the effects of simultaneous horizontal and vertical excitation on the response of the HTGR core. The tests were conducted with block array models of the core excited with both fixed frequency and sweeping frequency harmonic forcing functions. The effects on both free standing block arrays and on block arrays preloaded in the vertical direction were investigated. The results of the tests as well as their importance as regards to the full core response, are presented.

  20. Horizontal Accelerator

    Data.gov (United States)

    Federal Laboratory Consortium — The Horizontal Accelerator (HA) Facility is a versatile research tool available for use on projects requiring simulation of the crash environment. The HA Facility is...

  1. Testing the suitability of the Nepal-Somers stand table projection ...

    African Journals Online (AJOL)

    We also made an attempt to present a comprehensive example of a projection to facilitate practical application of this method in the KwaZulu-Natal coastal plain of South Africa. Keywords: CCT experiments, dbh distribution, parameter recovery, stand table projection, Weibull distribution. Southern Forests 2009, 71(3): 207– ...

  2. Absolute and Relative Reliability of the Timed 'Up & Go' Test and '30second Chair-Stand' Test in Hospitalised Patients with Stroke.

    Science.gov (United States)

    Lyders Johansen, Katrine; Derby Stistrup, Rikke; Skibdal Schjøtt, Camilla; Madsen, Jacqueline; Vinther, Anders

    2016-01-01

    The timed 'Up & Go' test and '30second Chair-Stand' test are simple clinical outcome measures widely used to assess functional performance. The reliability of both tests in hospitalised stroke patients is unknown. The purpose was to investigate the relative and absolute reliability of both tests in patients admitted to an acute stroke unit. Sixty-two patients (men, n = 41) attended two test sessions separated by a one hours rest. Intraclass correlation coefficients (ICC2,1) were calculated to assess relative reliability. Absolute reliability was expressed as Standard Error of Measurement (with 95% certainty-SEM95) and Smallest Real Difference (SRD) and as percentage of their respective means if heteroscedasticity was observed in Bland Altman plots (SEM95% and SRD%). ICC values for interrater reliability were 0.97 and 0.99 for the timed 'Up & Go' test and 0.88 and 0.94 for '30second Chair-Stand' test, respectively. ICC values for intrarater reliability were 0.95 and 0.96 for the timed 'Up & Go' test and 0.87 and 0.91 for '30second Chair-Stand' test, respectively. Heteroscedasticity was observed in the timed 'Up & Go' test. Interrater SEM95% ranged from 9.8% to 14.2% with corresponding SRD% of 13.9-20.1%. Intrarater SEM95% ranged from 15.8% to 18.7% with corresponding SRD% of 22.3-26.5%. For '30second Chair-Stand' test interrater SEM95 ranged between 1.5 and 1.9 repetitions with corresponding SRD of 2 and 3 and intrarater SEM95 ranged between 1.8 and 2.0 repetitions with corresponding SRD values of 3. Excellent reliability was observed for the timed 'Up & Go' test and the '30second Chair-Stand' test in hospitalised stroke patients. The thresholds to detect a real change in performance were 18.7% for the timed 'Up & Go' test and 2.0 repetitions for the '30second Chair-Stand' in groups of patients and 26.5% and 3 repetitions in individual patients, respectively.

  3. Experimental investigation of the two-phase flow regimes and pressure drop in horizontal mini-size rectangular test section

    Science.gov (United States)

    Elazhary, Amr Mohamed; Soliman, Hassan M.

    2012-10-01

    An experimental study was conducted in order to investigate two-phase flow regimes and fully developed pressure drop in a mini-size, horizontal rectangular channel. The test section was machined in the form of an impacting tee junction in an acrylic block (in order to facilitate visualization) with a rectangular cross-section of 1.87-mm height on 20-mm width on the inlet and outlet sides. Pressure drop measurement and flow regime identification were performed on all three sides of the junction. Air-water mixtures at 200 kPa (abs) and room temperature were used as the test fluids. Four flow regimes were identified visually: bubbly, plug, churn, and annular over the ranges of gas and liquid superficial velocities of 0.04 ≤ JG ≤ 10 m/s and 0.02 ≤ JL ≤ 0.7 m/s, respectively, and a flow regime map was developed. Accuracy of the pressure-measurement technique was validated with single-phase, laminar and turbulent, fully developed data. Two-phase experiments were conducted for eight different inlet conditions and various mass splits at the junction. Comparisons were conducted between the present data and former correlations for the fully developed two-phase pressure drop in rectangular channels with similar sizes. Wide deviations were found among these correlations, and the correlations that agreed best with the present data were identified.

  4. Number of test trials needed for performance stability and interrater reliability of the one leg stand test in patients with a major non-traumatic lower limb amputation

    DEFF Research Database (Denmark)

    Kristensen, Morten Tange; Nielsen, Anni Østergaard; Madsen Topp, Ulla

    2014-01-01

    Balance is beneficial for daily functioning of patients with a lower limb amputation and sometimes assessed by the one-leg stand test (OLST). The aims of the study were to examine (1) the number of trials needed to achieve performance stability, (2) the interrater reliability of the OLST...

  5. Significance of the 'bow and lean test' for the diagnosis of benign horizontal semicircular canal paroxysmal positional vertigo

    Directory of Open Access Journals (Sweden)

    Ying CHEN

    2012-10-01

    Full Text Available Objective To observe and assess the positive rate and accuracy of 'bow and lean test' in the horizontal semicircular canal benign paroxysmal positional vertigo (HSC-BPPV. Methods Ninety-two HSC-BPPV patients who were diagnosed by head roll test (HRT were enrolled, and then further tested with 'bow and lean test' (BLT between Oct 1, 2010 and Sep 30, 2011. They were treated by Barbecue maneuver or Brandt-Daroff exercise on the basis of HRT and BLT tests. The positive rate of BLT test was analyzed, and its accuracy for diagnosis and success rate for treatment of HSC-BPPV were compared between HRT and BLT. Results Among the 92 patients, 83(90.2% of them showed BLT nystagmus. Fifty-seven of 83 (68.7% patients showed both bowing nystagmus and leaning nystagmus, and 18(21.7% and 8(9.6% respectively showed bowing nystagmus alone or leaning nystagmus alone. Among 92 patients, 74(80.4% of them the affected side could be determined by HRT with 69 BLT positive and 5 BLT negative. Among the 69 BLT-positive patients, 60 patients showed the same result of HRT, and successful result was achieved by manipulation. 9 patients showed different result between BLT and HRT, in whom manipulation failed according to the result of HRT, but succeeded when manipulation was performed according to BLT. In 18 patients(19.6% it was not able to determine the affected side by HRT, but in 14 patients manipulation was successful when BLT result was applied. In 4 patients BLT failed to evoke nystagmus, but after practicing Brandt-Daroff exercise, vertigo and HRT nystagmus disappeared 3 days later. Among the 92 patients, 65(70.7% were cured according to HRT, while 83(90.2% got successful result according to BLT(P < 0.05. Conclusion The positive rate and accuracy for HSC-BPPV by BLT are high. It is a useful method for determining the affected side in HSC-BPPV, and to provide the basis for selecting effective manipulation treatment.

  6. Status of DOE and AID stand-alone photovoltaic system field tests

    Science.gov (United States)

    Bifano, W. J.; Delombard, R.; Ratajczak, A. F.; Scudder, L. R.

    1984-01-01

    The NASA Lewis Research Center (LeRC) is managing stand-alone photovoltaic (PV) system projects sponsored by the U.S. Department of Energy (DOE) and the U.S. Agency for International Development (AID). The DOE project includes village PV power demonstration projects in Gabon (four sites) and the Marshall Islands, and PV-powered vaccine refrigerator systems in six countries. The AID project includes a large village power system, a farmhouse system and two water pumping-irrigation systems in Tunisia, a water pumping/grain grinding system in Upper Volta, five medical clinic systems in four countries, PV-powered vaccine refrigerator systems in 18 countries and a PV-powered remote earth station in Indonesia. This paper reviews these PV projects and summarizes significant findings to date.

  7. The effect of a dragging anchor on a horizontal layer of rockfill : A Prototype and a Scale Model Test

    NARCIS (Netherlands)

    Crum, S.; Van der Hoeven, M.L.E.B.; Krouwel, L.P.H.C.; Verhagen, H.J.

    2015-01-01

    Quantifying the penetration depth of a dragging anchor on a horizontal layer of rockfill provides the possibility to optimize the layer thickness of rockfill layers with a protective function. Current research on this subject is limited and is often aimed at anchor capacities in sand and clay.

  8. Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals

    Directory of Open Access Journals (Sweden)

    Keisuke Nakamura, Masayoshi Ohira, Yoshiharu Yokokawa, Yuya Nagasawa

    2015-12-01

    Full Text Available Sit-to-stand exercise (STS is a common activity of daily living. The objectives of the present study were: 1 to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs, during incremental sit-to-stand exercise (ISTS with and without arm support compared with an incremental cycle-ergometer (CE test; and 2 to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2 and heart rate at the AT (AT-HR were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey’s post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05; AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05; AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05; and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05. The AT-VO2 values during the ISTS with arm support (18.5 ± 1.9 mL·min-1·kg-1 and the CE test (18.4 ± 1.8 mL·min-1·kg-1 were significantly higher than those during the ISTS without arm support (16.6 ± 1.8 mL·min-1·kg-1; p < 0.05. The AT-HR values during the ISTS with arm support (126 ± 10 bpm and the CE test (126 ± 13 bpm were significantly higher than those during the ISTS without arm support (119 ± 9 bpm; p < 0.05. The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.

  9. INTRODUCING NOVEL GENERATION OF HIGH ACCURACY CAMERA OPTICAL-TESTING AND CALIBRATION TEST-STANDS FEASIBLE FOR SERIES PRODUCTION OF CAMERAS

    Directory of Open Access Journals (Sweden)

    M. Nekouei Shahraki

    2015-12-01

    Full Text Available The recent advances in the field of computer-vision have opened the doors of many opportunities for taking advantage of these techniques and technologies in many fields and applications. Having a high demand for these systems in today and future vehicles implies a high production volume of video cameras. The above criterions imply that it is critical to design test systems which deliver fast and accurate calibration and optical-testing capabilities. In this paper we introduce new generation of test-stands delivering high calibration quality in single-shot calibration of fisheye surround-view cameras. This incorporates important geometric features from bundle-block calibration, delivers very high (sub-pixel calibration accuracy, makes possible a very fast calibration procedure (few seconds, and realizes autonomous calibration via machines. We have used the geometrical shape of a Spherical Helix (Type: 3D Spherical Spiral with special geometrical characteristics, having a uniform radius which corresponds to the uniform motion. This geometrical feature was mechanically realized using three dimensional truncated icosahedrons which practically allow the implementation of a spherical helix on multiple surfaces. Furthermore the test-stand enables us to perform many other important optical tests such as stray-light testing, enabling us to evaluate the certain qualities of the camera optical module.

  10. Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals.

    Science.gov (United States)

    Nakamura, Keisuke; Ohira, Masayoshi; Yokokawa, Yoshiharu; Nagasawa, Yuya

    2015-12-01

    Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 ± 1.9 mL·min(-1)·kg(-1)) and the CE test (18.4 ± 1.8 mL·min(-1)·kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 ± 1.8 mL·min(-1)·kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 ± 10 bpm) and the CE test (126 ± 13 bpm) were significantly higher than those during the ISTS without arm support (119 ± 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults. Key pointsThe ISTS is a simple test that varies only according to the frequency of standing up, and requires only

  11. Integrated Component and System Analyses of Instabilities in Test Stands Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Instabilities associated with fluid handling and operation in liquid rocket propulsion systems and test facilities usually manifest themselves as structural...

  12. Integrated Component and System Analyses of Instabilities in Test Stands Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Instabilities associated with the operation of liquid rocket propulsion systems and test facilities usually manifest themselves as structural vibrations and may...

  13. Last Stand-alone Beam Test of the Hadronic End-cap Calorimeter (HEC) Finished.

    CERN Multimedia

    Oberlack, H

    One quarter of all 134 HEC modules are tested with electron, pion and muon beams: two "partial HEC wheels", three HEC1 modules and three HEC2 modules, are used in a standard setup using the HEC cryostat in the H6 beam line. The picture shows a view of the set-up in the cryostat during the installation. MC results show that in this setup the energy leakage is well under control - well below 5 %. In addition, the other three quarters of modules are tested in technical cold tests. Using calibration signals, a detailed test of the cabling, cold electronics, crosstalk and noise performance is being done. The beam tests started with four prototype modules per run in '97, when technological optimization was still the key issue. From '98 onwards, modules of the "module 0" type have been tested, typically in two run periods per year. Finally in '99 the series production has started, with first beam test of series modules in 2000. Since then 57 series modules have been cold tested, 24 of them actually in beam tests. T...

  14. Association of Seat Height and Arm Position on the Five Times Sit-to-Stand Test Times of Stroke Survivors

    Science.gov (United States)

    Ng, Shamay S. M.; Cheung, Susanna Y.; Lai, Lauren S. W.; Liu, Ann S. L.; Ieong, Selena H. I.; Fong, Shirley S. M.

    2013-01-01

    Objectives. To investigate (1) the association of seat height and (2) the association of arm position on the five times sit-to-stand test (FTSTS) times of individuals with stroke. Design. A cross-sectional study. Setting. University-based rehabilitation centre. Subjects. Patients (n = 43) with chronic stroke. Methods. The times in completing the FTSTS with different seat height (85%, 100%, and 115% knee height) and arm positions (arms across chest, hands on thighs). Results. FTSTS times were significantly different between 85% and 100% seat heights, and between the 85% and 115% seat heights in both arm positions. However, there was no significant difference between the FTSTS times with the two arm positions at any seat height tested. Conclusion. Seat heights lower than the knee height result in longer FTSTS times, whereas arms positions did not significantly affect the FTSTS times. PMID:24106711

  15. Design, installation, commissioning and operation of a beamlet monitor in the negative ion beam test stand at NIFS

    Energy Technology Data Exchange (ETDEWEB)

    Antoni, V.; Agostinetti, P.; Brombin, M.; Cervaro, V.; Delogu, R.; Fasolo, D.; Franchin, L.; Ghiraldelli, R.; Molon, F.; Pasqualotto, R.; Serianni, G., E-mail: gianluigi.serianni@igi.cnr.it; Tollin, M.; Veltri, P. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); De Muri, M. [Consorzio RFX (CNR, ENEA, INFN, Università di Padova, Acciaierie Venete SpA) (Italy); INFN-LNL, v.le dell' Università 2, I-35020, Legnaro (PD) Italy (Italy); Ikeda, K.; Kisaki, M.; Nakano, H.; Takeiri, Y.; Tsumori, K. [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Muraro, A. [Istituto di Fisica del Plasma (IFP-CNR) – Via Cozzi 53, 20125, Milano (Italy)

    2015-04-08

    In the framework of the accompanying activity for the development of the two neutral beam injectors for the ITER fusion experiment, an instrumented beam calorimeter is being designed at Consorzio RFX, to be used in the SPIDER test facility (particle energy 100keV; beam current 50A), with the aim of testing beam characteristics and to verify the source proper operation. The main components of the instrumented calorimeter are one-directional carbon-fibre-carbon composite tiles. Some prototype tiles have been used as a small-scale version of the entire calorimeter in the test stand of the neutral beam injectors of the LHD experiment, with the aim of characterising the beam features in various operating conditions. The extraction system of the NIFS test stand source was modified, by applying a mask to the first gridded electrode, in order to isolate only a subset of the beamlets, arranged in two 3×5 matrices, resembling the beamlet groups of the ITER beam sources. The present contribution gives a description of the design of the diagnostic system, including the numerical simulations of the expected thermal pattern. Moreover the dedicated thermocouple measurement system is presented. The beamlet monitor was successfully used for a full experimental campaign, during which the main parameters of the source, mainly the arc power and the grid voltages, were varied. This contribution describes the methods of fitting and data analysis applied to the infrared images of the camera to recover the beamlet optics characteristics, in order to quantify the response of the system to different operational conditions. Some results concerning the beamlet features are presented as a function of the source parameters.

  16. Atmospheric Test Models and Numerical Experiments for the Simulation of the Global Distributions of Weather Data Transponders III. Horizontal Distributions

    Energy Technology Data Exchange (ETDEWEB)

    Molenkamp, C.R.; Grossman, A.

    1999-12-20

    A network of small balloon-borne transponders which gather very high resolution wind and temperature data for use by modern numerical weather predication models has been proposed to improve the reliability of long-range weather forecasts. The global distribution of an array of such transponders is simulated using LLNL's atmospheric parcel transport model (GRANTOUR) with winds supplied by two different general circulation models. An initial study used winds from CCM3 with a horizontal resolution of about 3 degrees in latitude and longitude, and a second study used winds from NOGAPS with a 0.75 degree horizontal resolution. Results from both simulations show that reasonable global coverage can be attained by releasing balloons from an appropriate set of launch sites.

  17. Intra-observer and interobserver reliability ofOne Leg Stand Test as a measure of posturalbalance in low back pain patients

    DEFF Research Database (Denmark)

    Maribo, Thomas; Iversen, Elena; Andersen, Niels Trolle

    2009-01-01

    Objective: To determine the absolute and relative reliability of intra-observer and interobserver To determine the absolute and relative reliability of intra-observer and interobserver measurements of postural balance using the One Leg Stand Test in patients with low back pain. Patients and methods...... in patients with chronic The One Leg Stand Test can be used to test postural balance in patients with chronic low back pain, as the reliability of the test was acceptable.......: Forty-eight patients with chronic low back pain advised to do exercise were : Forty-eight patients with chronic low back pain advised to do exercise were included. A test protocol was established based on review of the literature and a pilot test. Patients were timed for their ability to stand on one...

  18. RF and data acquisition systems for Fermilab's ILC SRF cavity vertical test stand

    Energy Technology Data Exchange (ETDEWEB)

    Ozelis, Joseph P.; Nehring, Roger; /Fermilab; Grenoble, Christiana; Powers, Thomas J.; /Jefferson Lab

    2007-06-01

    Fermilab is developing a facility for vertical testing of SRF cavities as part of its ILC program. The RF system for this facility is based on the proven production cavity test systems used at Jefferson Lab for CEBAF and SNS cavity testing. The design approach is modular in nature, using commercial-off-the-shelf (COTS) components. This yields a system that can be easily debugged and modified, and with ready availability of spares. Comprehensive data acquisition and control is provided by a PXI-based hardware platform in conjunction with software developed in the LabView programming environment.

  19. Drive Stands

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrical Systems Laboratory (ESL)houses numerous electrically driven drive stands. A drive stand consists of an electric motor driving a gearbox and a mounting...

  20. RF and Data Acquisition Systems for Fermilab's ILC SRF Cavity Vertical Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Joseph P. Ozelis; Roger Nehring; Christiana Grenoble; Thomas J. Powers

    2007-06-01

    Fermilab is developing a facility for vertical testing of SRF cavities as part of a program to improve cavity performance reproducibility for the ILC. The RF system for this facility, using the classic combination of oscillator, phase detector/mixer, and loop amplifier to detect the resonant cavity frequency and lock onto the cavity, is based on the proven production cavity test systems used at Jefferson Lab for CEBAF and SNS cavity testing. The design approach is modular in nature, using commercial-off-the-shelf (COTS) components. This yields a system that can be easily debugged and modified, and with ready availability of spares. Data acquisition and control is provided by a PXI-based hardware platform in conjunction with software developed in the LabView programming environment. This software provides for amplitude and phase adjustment of incident RF power, and measures all relevant cavity power levels, cavity thermal environment parameters, as well as field emission-produced radiation. It also calculates the various cavity performance parameters and their associated errors. Performance during system commissioning and initial cavity tests will be presented.

  1. First Results from Beam Measurements at the 3 MeV Test Stand for CERN LINAC4

    CERN Document Server

    Cheymol, B; Lokhovitsky, A; Midttun, O; Raich, U; Roncarolo, F; Scrivens, R; Zorin, E

    2011-01-01

    The H- source and the low energy beam transport(LEBT) line will determine to a large extend the performance of Linac-4, the new machine foreseen at CERN as injector into the PS Booster. For this reason a test stand is being set up, consisting of the source, the LEBT, the RFQ and the chopper line. Up to now only the source and LEBT are installed. First measurements have been performed using a Faraday Cup to measure the total source intensity, a slit and grid emittance meter for transverse emittance measurements as well as a spectrometer for energy spread measurements. Beam intensity, profile, transverse emittance and energy spread have been measured. The paper discusses measurements done on H- beams at 35 kV extraction voltage as well as proton beams at 45 keV.

  2. Cryogenic instrumentation of an SSC (superconducting super collider) magnet test stand

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, K.; Strait, J.; Kuchnir, M.; McInturff, A.

    1987-09-01

    This paper describes the system used to acquire cryogenic data for the testing of SSC magnets at the Fermilab Magnet Test Facility. An array of pressure transducers, resistance thermometers, vapor pressure thermometers, and signal conditioning circuits are used. Readings with time resolution appropriate for quench recording are obtained with a waveform digitizer and steady-state measurements are obtained with higher accuracy using a digital voltmeter. The waveform digitizer is clocked at a 400 Hz sampling rate and these readings are stored in local ring buffers. The system is modular and can be expanded to add more channels. The software for the acquisition, control, logging, and display of cryogenic data consist of two programs which run as separate tasks. These programs (as well as a third program which acquires quench and magnetic data) communicate and pass data using shared global resources. The acquired data are available for analysis via a nationwide DECnet network.

  3. Development of an Optimal Controller and Validation Test Stand for Fuel Efficient Engine Operation

    Science.gov (United States)

    Rehn, Jack G., III

    There are numerous motivations for improvements in automotive fuel efficiency. As concerns over the environment grow at a rate unmatched by hybrid and electric automotive technologies, the need for reductions in fuel consumed by current road vehicles has never been more present. Studies have shown that a major cause of poor fuel consumption in automobiles is improper driving behavior, which cannot be mitigated by purely technological means. The emergence of autonomous driving technologies has provided an opportunity to alleviate this inefficiency by removing the necessity of a driver. Before autonomous technology can be relied upon to reduce gasoline consumption on a large scale, robust programming strategies must be designed and tested. The goal of this thesis work was to design and deploy an autonomous control algorithm to navigate a four cylinder, gasoline combustion engine through a series of changing load profiles in a manner that prioritizes fuel efficiency. The experimental setup is analogous to a passenger vehicle driving over hilly terrain at highway speeds. The proposed approach accomplishes this using a model-predictive, real-time optimization algorithm that was calibrated to the engine. Performance of the optimal control algorithm was tested on the engine against contemporary cruise control. Results indicate that the "efficient'' strategy achieved one to two percent reductions in total fuel consumed for all load profiles tested. The consumption data gathered also suggests that further improvements could be realized on a different subject engine and using extended models and a slightly modified optimal control approach.

  4. Armillaria species in coniferous stands

    Directory of Open Access Journals (Sweden)

    Anna Żółciak

    2013-12-01

    Full Text Available Identification of the Armillaria species in selected coniferous stands (Scots pine stands, Norway spruce stands and fir stands was the aim of the work carried out on the basis of mating tests and consideration of macroscopic traits of fruit-bodies. One species of Armillaria [A. ostoyae (Romagnesi Herink] was found in Scots pine stands, three species [A. ostoyae, A. cepistipes Velenovský and A. borealis Marxmüller et Korhonen] were found in Norway spruce stands and two species [A. ostoyae and A. cepistipes] were found in fir stands.

  5. Avaliação do Comprimento do Colo Uterino nas Posições Ortostática e Decúbito Horizontal nas Gestações Gemelares Uterine Cervical Length Evaluation in the Standing and Recumbent Positions in Twin Pregnancies

    Directory of Open Access Journals (Sweden)

    Tatiana Bernáth

    2002-05-01

    Full Text Available Objetivo: avaliação ultra-sonográfica e comparação da medida do comprimento do colo uterino nas gestações gemelares com as pacientes nas posições de decúbito dorsal horizontal (DDH e ortostática. Métodos: 50 gestações gemelares foram submetidas a avaliações ultra-sonográficas para medida do comprimento do colo uterino no período de maio de 1999 a dezembro de 2000. Os exames foram realizados pela via transvaginal com periodicidade de 4 semanas totalizando 136 avaliações. A cérvice uterina foi avaliada, segundo técnica normatizada, com a paciente nas posições de decúbito dorsal horizontal e ortostática. Resultados: as medidas do colo uterino nas posições DDH e ortostática na primeira avaliação apresentaram correlação inversa com a idade gestacional (DDH: r=-0,60; pPurpose: to compare cervical length measurements in twin pregnancies obtained by transvaginal ultrasound examination in the recumbent and standing positions. Methods: fifty twin pregnancies underwent transvaginal ultrasound examinations to measure the cervical length with the women in recumbent and standing positions. The study was carried out between May 1999 and December 2000. The scans were repeated every 4 weeks and the total number of evaluations was 136. Two groups were analyzed: one included only the first ultrasound examinations carried out in each woman and the second group included all evaluations. Results: in the first group, cervical length measurements in the standing and recumbent positions correlated inversely with the gestational age (recumbent: r=-0.60; p<0.001; standing: r=-0.46; p=0.008. The mean measure in the recumbent position was 35.2 mm (SD=9.9 mm and 33.4 mm (SD=9.5 mm in the standing position. When the difference between the measure obtained in the standing and recumbent positions was expressed as percentage of the measure in the recumbent position, there was no significant association with gestational age (p=0.07. When all

  6. SHORT-COMMUNICATION. Integration drum test stand and a dynamometer trailer for testing car tires with using LabVIEW

    Directory of Open Access Journals (Sweden)

    Andrzej Dębowski

    2016-03-01

    Full Text Available The paper presents the construction of the station for dynamic tests tires using measurement platform Compact RIO and LabVIEW located at the Institute of Motor Vehicles and Transport WAT.

  7. Status of High Power Tests of Normal Conducting Single-Cell Standing Wave Structures

    Energy Technology Data Exchange (ETDEWEB)

    Dolgashev, Valery; /SLAC; Tantawi, Sami; /SLAC; Yeremian, Anahid; /SLAC; Higashi, Yasuo; /KEK, Tsukuba; Spataro, Bruno; /INFN, Rome

    2012-06-25

    Our experiments are directed toward the understanding of the physics of rf breakdown in systems that can be used to accelerate electron beams at {approx}11.4 GHz. The structure geometries have apertures, stored energy per cell, and rf pulse duration close to that of the NLC or CLIC. The breakdown rate is the main parameter that we use to compare rf breakdown behavior for different structures at a given set of rf pulse parameters (pulse shape and peak power) at 60 Hz repetition rate. In our experiments, the typical range of the breakdown rate is from one per few hours to {approx}100 per hour. To date we have tested 29 structures. We consistently found that after the initial conditioning, the behavior of the breakdown rate is reproducible for structures of the same geometry and material, and the breakdown rate dependence on peak magnetic fields is stronger than on peak surface electric fields for structures of different geometries. Below we report the main results from tests of seven structures made from hard copper, soft copper alloys and hard-copper alloys. Additional details on these and other structures will be discussed in future publications.

  8. Development of an Army Stationary Axle Efficiency Test Stand - Interim Report TFLRF No. 471

    Science.gov (United States)

    2015-09-01

    A Plus, Mack mDRIVE  International TMS 6816  ZF-FreedomLine (ZF-AS Tronic)  Meritor O81  Volvo 97305, Volvo I-Shift (75,000 miles) Fleetrite...Foam  GM – 6.5L (RFWT)  Volvo – VDS-2, VDS-3, VDS-4 (15W-40)  Global – DHD-1  JASO – DH-1  Daimler Chrysler – P228.3  ACEA – E7-04, E2, E4...Coolant Cavitation Test) Meets or exceeds these performance requirements:  John Deere H24A1, H24C1  PACCAR  Volvo /Mack  TMC RP 329 NOAT

  9. Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests.

    Directory of Open Access Journals (Sweden)

    Cristina Roldán-Jiménez

    Full Text Available Sit-to-stand (STS tests measure the ability to get up from a chair, reproducing an important component of daily living activity. As this functional task is essential for human independence, STS performance has been studied in the past decades using several methods, including electromyography. The aim of this study was to measure muscular activity and fatigue during different repetitions and speeds of STS tasks using surface electromyography in lower-limb and trunk muscles. This cross-sectional study recruited 30 healthy young adults. Average muscle activation, percentage of maximum voluntary contraction, muscle involvement in motion and fatigue were measured using surface electrodes placed on the medial gastrocnemius (MG, biceps femoris (BF, vastus medialis of the quadriceps (QM, the abdominal rectus (AR, erector spinae (ES, rectus femoris (RF, soleus (SO and the tibialis anterior (TA. Five-repetition STS, 10-repetition STS and 30-second STS variants were performed. MG, BF, QM, ES and RF muscles showed differences in muscle activation, while QM, AR and ES muscles showed significant differences in MVC percentage. Also, significant differences in fatigue were found in QM muscle between different STS tests. There was no statistically significant fatigue in the BF, MG and SO muscles of the leg although there appeared to be a trend of increasing fatigue. These results could be useful in describing the functional movements of the STS test used in rehabilitation programs, notwithstanding that they were measured in healthy young subjects.

  10. Muscular Activity and Fatigue in Lower-Limb and Trunk Muscles during Different Sit-To-Stand Tests.

    Science.gov (United States)

    Roldán-Jiménez, Cristina; Bennett, Paul; Cuesta-Vargas, Antonio I

    2015-01-01

    Sit-to-stand (STS) tests measure the ability to get up from a chair, reproducing an important component of daily living activity. As this functional task is essential for human independence, STS performance has been studied in the past decades using several methods, including electromyography. The aim of this study was to measure muscular activity and fatigue during different repetitions and speeds of STS tasks using surface electromyography in lower-limb and trunk muscles. This cross-sectional study recruited 30 healthy young adults. Average muscle activation, percentage of maximum voluntary contraction, muscle involvement in motion and fatigue were measured using surface electrodes placed on the medial gastrocnemius (MG), biceps femoris (BF), vastus medialis of the quadriceps (QM), the abdominal rectus (AR), erector spinae (ES), rectus femoris (RF), soleus (SO) and the tibialis anterior (TA). Five-repetition STS, 10-repetition STS and 30-second STS variants were performed. MG, BF, QM, ES and RF muscles showed differences in muscle activation, while QM, AR and ES muscles showed significant differences in MVC percentage. Also, significant differences in fatigue were found in QM muscle between different STS tests. There was no statistically significant fatigue in the BF, MG and SO muscles of the leg although there appeared to be a trend of increasing fatigue. These results could be useful in describing the functional movements of the STS test used in rehabilitation programs, notwithstanding that they were measured in healthy young subjects.

  11. Differences in autonomic balance in patients with cardioinhibitory and vasodepressor type of reflex syncope during head-up tilt test and active standing

    DEFF Research Database (Denmark)

    Holmegard, Haya N; Benn, Marianne; Kaijer, Michelle

    2012-01-01

    To improve the pathophysiological understanding of cardioinhibitory and vasodepressor reflex syncope, by evaluating orthostatic effects on electrical and hemodynamic variables. To unravel the pathogeneses further, we studied these effects during both the passive head-up tilt test and the active...... standing test....

  12. Standing of nucleic acid testing strategies in veterinary diagnosis laboratories to uncover Mycobacterium tuberculosis complex members

    Directory of Open Access Journals (Sweden)

    Pedro eCosta

    2014-10-01

    Full Text Available Nucleic acid testing (NAT designate any molecular approach used for the detection, identification and characterization of pathogenic microorganisms, enabling the rapid, specific and sensitive diagnostic of infectious diseases, such as tuberculosis. These assays have been widely used since the 90´s of the last century in human clinical laboratories and, subsequently, also in veterinary diagnostics. Most NAT strategies are based in the polymerase chain reaction (PCR and its several enhancements and variations. From the conventional PCR, real-time PCR and its combinations, isothermal DNA amplification, to the nanotechnologies, here we review how the NAT assays have been applied to decipher if and which member of the Mycobacterium tuberculosis complex is present in a clinical sample. Recent advances in DNA sequencing also brought new challenges and have made possible to generate rapidly and at a low cost, large amounts of sequence data. This revolution with the high-throughput sequencing (HTS technologies makes whole genome sequencing (WGS and metagenomics the trendiest NAT strategies, today. The ranking of NAT techniques in the field of clinical diagnostics is rising, and we provide a SWOT (Strengths, Weaknesses, Opportunities and Threats analysis with our view of the use of molecular diagnosis for detecting tuberculosis in veterinary laboratories, notwithstanding the gold standard being still the classical culture of the agent. The complementary use of both classical and molecular diagnosis approaches is recommended to speed the diagnostic, enabling a fast decision by competent authorities and rapid tackling of the disease.

  13. Static postural control with aging in a vertical direction and on a horizontal plane

    OpenAIRE

    Yumi, Asano; Ichiro, Shimoyama; Atsushi, Murata

    2009-01-01

    Postural control in standing balance was analyzed in 80 volunteers, aged 31 to 92 years, who were free from equilibrium disease. Center of foot pressure (COP) was measured on a horizontal plane and in a vertical direction, during 20 sec with eyes open and 20 sec with eyes closed. COP-path length and COP-path area were obtained on the horizontal plane, and coefficient of correlation was tested for them with age, body weight and height. Integrated power between 0 and 10 Hz was tested for the ho...

  14. Current standing and future prospects for the technologies proposed to transform toxicity testing in the 21st century.

    Science.gov (United States)

    van Vliet, Erwin

    2011-01-01

    The National Academy of Sciences publication, Toxicity Testing in the 21st Century: A Vision and a Strategy, proposes a paradigm shift in toxicology from current animal-based testing towards the application of emerging technologies, i.e., assays based on human cells or non-mammalian models, high throughput testing, omics approaches, systems biology, and computational modeling. These technologies should be used to identify how chemicals interact with cellular response networks and alter them to toxicity pathways. According to the authors, such a new paradigm would provide a better scientific understanding and more adequate data to predict the adverse effects of chemicals on human health. As expected from a vision document, the report enthusiastically and optimistically describes a radical transformation of toxicology from current practices to a new approach. Several toxicologists have commented on the report, and although they generally confirm the importance of the vision, they pose critical questions regarding its feasibility. Unlike the theoretical concepts, which are carefully described, many practical aspects of how to establish the vision are less well defined. Today's technologies provide great opportunities, although many challenges remain regarding their development, implementation, and validation to adequately assess human health effects. To bring the envisioned toxicology closer to concrete implementation, it is important to identify the current knowledge gaps in the vision and develop solutions. The goal of this review is to evaluate the technologies proposed as to their maturation to transform toxicity testing in the 21st century. This paper will provide an overview of the current standing by defining advantages, limitations, and developmental needs. In doing so, I do not intend to point out obstacles but, rather, to focus on current opportunities to advance toxicity testing for human risk assessment.

  15. Inter-rater reliability of the Active Straight-Leg Raise and One-Leg Standing tests in non-pregnant women.

    Science.gov (United States)

    Kwong, Evan H; Virani, Noorshina; Robert, Magali; Gerry, Kate; Harding, Anita; Rose, M Sarah; Dukelow, Sean P; Barton, Pamela M

    2013-11-01

    To determine the inter-rater reliability of the Active Straight-Leg Raise and One-Leg Standing tests. Cross-sectional pilot study. Thirty-one women who were either not pregnant or at least 9 months post-partum. Subjects completed a questionnaire and standardized pain and disability assessments. The Active Straight-Leg Raise and One-Leg Standing tests were assessed by 3 independent, blinded examiners. Inter-rater reliability was determined, and relationships with assessments were explored. For the Active Straight-Leg Raise test, the kappa coefficient was 0.87, sensitivity 71%, and specificity 91%. Relationships with various pain and disability assessments were demonstrated, including the Functional Pelvic Pain Scale (r = 0.77) and Roland-Morris Disability Questionnaire (r = 0.70). For the One-Leg Standing test, kappa coefficients were -0.02 and 0.14 for the left and right sides, respectively, and thus no further analyses were performed. In women with a spectrum of low-back and pelvic pain, the Active Straight-Leg Raise test had good inter-rater reliability, whereas the One-Leg Standing test did not. Further studies are required regarding the validity of the Active Straight-Leg Raise test.

  16. Three-Month Test-Retest Reliability of Center of Pressure Motion During Standing Balance in Individuals with Multiple Sclerosis.

    Science.gov (United States)

    Wajda, Douglas A; Motl, Robert W; Sosnoff, Jacob J

    2016-01-01

    Balance impairment and an increased rate of falls are commonly reported in individuals with multiple sclerosis (MS). Force platform-generated center of pressure (COP) metrics have previously been recommended as an outcome measure to quantify balance deficits and distinguish between fallers and nonfallers in MS. Information is limited regarding the preservation of postural control in individuals with MS over extended time frames in the absence of an intervention. This report examines the test-retest reliability and magnitude of change of COP motion during standing balance over 3 months. Twenty individuals with MS and a history of falling underwent testing on two occasions 3 months apart in the absence of an intervention. On both occasions, participants completed two 30-second trials of three conditions: eyes open, eyes closed, and eyes open with concurrent cognitive challenge (dual task). Measures of COP area, velocity, and temporal structure were calculated and included in the reliability analysis. The COP metrics displayed fair-to-excellent reliability over 3 months without an intervention. Reliability was maintained across the three commonly used balance conditions. These results offer insight into the reliability of COP measures over a 3-month period in MS and can inform the use of COP metrics for future study design (eg, sample size estimates) and balance outcome assessment during randomized controlled trials and fall-prevention studies in individuals with MS.

  17. Outdoor test stand performance of a convertible engine with variable inlet guide vanes for advanced rotorcraft propulsion

    Science.gov (United States)

    Mcardle, Jack G.

    1986-01-01

    A variable inlet guide van (VIGV) type convertible engine that could be used to power future high-speed rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip airflow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque. Previous mission analyses of a conceptual X-wing rotorcraft capable of 400-knot cruise speed were revised to account for more fan-tip churning power loss than was originally estimated. The new calculations confirm that using convertible engines rather than separate lift and cruise engines would result in a smaller, lighter craft with lower fuel use and direct operating cost.

  18. Lumbar spine stability for subjects with and without low back pain during one-leg standing test.

    Science.gov (United States)

    Sung, Paul S; Yoon, BumChul; Lee, Dongchul C

    2010-07-15

    An experimental design comparing kinematic changes in the lumbar spine axis in subjects with and without low back pain (LBP) while standing on one leg with and without visual feedback. The purpose of this study was to evaluate the lumbar stability index, which includes relative holding time (RHT) and relative standstill time (RST), in subjects with and without LBP. Even though a number of studies have evaluated postural adjustments based on kinematic changes in subjects with LBP, lumbar spine stability has not been examined for abnormal postural responses with visual feedback. All participants were asked to maintain the stork test position (standing on one leg with the contra lateral hip flexed 90 degrees) for 25 seconds. The outcome measures included RHT and RST for the axes of the core spine and lumbar spine. Independent t tests were used to compare the differences between groups. Two-way repeated measure analysis of variance was used to compare the differences for both axes. The age variable was used as a covariate to control confounding effects for the data analyses. The RHT was longer for the lumbar spine axis in subjects without LBP than those with LBP, especially without visual feedback. There was also significant interaction in RST between subjects with and without LBP (F = 7.18, P = 0.01). For the core axis of the trunk, significant differences existed based on the main effect of side (F = 9.07, P = 0.004), trunk rotation (F = 24.30, P = 0.001), and both of these interactions (F = 8.93, P = 0.004). However, there was a lack of significant interaction with age for the lumbar and core spine axes (F = 0.06, P = 0.81). Although the control group included slightly younger volunteers compared with the LBP group, the stability index of the core spine significantly decreased in RHT and RST, especially when visual feedback was blocked for subjects with LBP. The interaction between visual feedback and trunk rotation indicated that core spine stability is critical in

  19. Analysis and test results for a two-bladed, passive cycle pitch, horizontal-axis wind turbine in free and controlled yaw

    Energy Technology Data Exchange (ETDEWEB)

    Holenemser, K.H. [Washington Univ., St. Louis, MO (United States)

    1995-10-01

    This report surveys the analysis and tests performed at Washington University in St. Louis, Missouri, on a horizontal-axis, two-laded wind turbine with teeter hub. The introduction is a brief account of results obtained during the 5-year period ending December 1985. The wind tunnel model and the test turbine (7.6 m [25 ft.] in diameter) at Washington University`s Tyson Research Center had a 67{degree} delta-three angle of the teeter axis. The introduction explains why this configuration was selected and named the passive cycle pitch (PCP) wind turbine. Through the analysis was not limited to the PCP rotor, all tests, including those done from 1986 to 1994, wee conducted with the same teetered wind rotor. The blades are rather stiff and have only a small elastic coning angle and no precone.

  20. Testing direct and interactive effects of tree size, stand competition, water balance, heat, and freezing on probability of mortality

    Science.gov (United States)

    Hember, R. A.; Kurz, W. A.; Coops, N. C.

    2016-12-01

    Water stress affects rates of tree mortality in diverse ways. In a previous study, we included standardized water-balance variables as predictors in conventional models of individual-tree mortality drawing on over 8 million observations for 64 North American tree species. We found that probability of tree mortality (Pm) was related to soil-water content (Ws) and/or reference evapotranspiration (ETref) in over 90 percent of the species samples and that sensitivity to water-balance variables was typically mediated by tree height (h) and aridity class (AC) of the site. Here we expand on the model-building exercise to test the additional hypotheses that: (1) sensitivity of Pm of short trees to water-balance variables increases with stand-level biomass of larger trees (BLS) due to competition among trees for access to soil water; (2) sensitivity of Pm to water-balance variables increases with temperature (T) due either to higher respiration or error in the expression of ETref and (3) sensitivity of Pm to water-balance variables increases with the number of days with frost (DWF) due to decreasing hydraulic conductance associated either with occurrence or avoidance of freezing-induced embolism. We describe whether the hypotheses are supported and how the modifications influence predictions of net ecosystem biomass production (NEBP) of North American forests over 1951-2014.

  1. Modeling and Experimental Test of Grid-Tied Photovoltaic Cell Emulating System in the Stand-alone Mode

    Directory of Open Access Journals (Sweden)

    Vu Minh Phap

    2017-06-01

    Full Text Available In recent decades, generation of electricity from solar arrays has been increased to meet the world's growing energy demand. However, the utilization rate of the power conditioner in the grid-tied solar power system is low because the operation of solar panels is dependent on sunlight. Thus, we studied the method that the small scale wind power generating system in size from a few hundred watts to two or three kilowatts can be connected to the grid-tied power conditioner of the solar power system for residential applications with low power ratings (single phase, size is limited to 10kW by emulating characteristic of the solar panel. In this paper, we introduce the application of the grid-tied PV cell emulating system in the stand-alone mode to improve the utilization rate of the power conditioner. The simulation and experimental test results verify that the PV cell emulating system can operate the power conditioner of the gridtied solar power system.

  2. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    CERN Document Server

    Adli, E; Dubrovskiy, A; Syratchev, I; Ruber, R; Ziemann, V

    2011-01-01

    We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter reg...

  3. X-band rf power production and deceleration in the two-beam test stand of the Compact Linear Collider test facility

    Directory of Open Access Journals (Sweden)

    E. Adli

    2011-08-01

    Full Text Available We discuss X-band rf power production and deceleration in the two-beam test stand of the CLIC test facility at CERN. The rf power is extracted from an electron drive beam by a specially designed power extraction structure. In order to test the structures at high-power levels, part of the generated power is recirculated to an input port, thus allowing for increased deceleration and power levels within the structure. The degree of recirculation is controlled by a splitter and phase shifter. We present a model that describes the system and validate it with measurements over a wide range of parameters. Moreover, by correlating rf power measurements with the energy lost by the electron beam, as measured in a spectrometer placed after the power extraction structure, we are able to identify system parameters, including the form factor of the electron beam. The quality of the agreement between model and reality gives us confidence to extrapolate the results found in the present test facility towards the parameter regime of CLIC.

  4. Approximation of the breast height diameter distribution of two-cohort stands by mixture models II Goodness-of-fit tests

    Science.gov (United States)

    Rafal Podlaski; Francis .A. Roesch

    2013-01-01

    The goals of this study are (1) to analyse the accuracy of the approximation of empirical distributions of diameter at breast height (dbh) using two-component mixtures of either the Weibull distribution or the gamma distribution in two−cohort stands, and (2) to discuss the procedure of choosing goodness−of−fit tests. The study plots were...

  5. Physics design of a 10 MeV injector test stand for an accelerator-driven subcritical system

    Directory of Open Access Journals (Sweden)

    Fang Yan

    2015-05-01

    Full Text Available The 10 MeV accelerator-driven subcritical system (ADS Injector I test stand at Institute of High Energy Physics (IHEP is a testing facility dedicated to demonstrate one of the two injector design schemes [Injector Scheme-I, which works at 325 MHz], for the ADS project in China. The injector is composed of two parts, the linac part and the beam dump line. The former is designed on the basis of 325 MHz four-vane type copper structure radio frequency quadrupole and superconducting (SC spoke cavities with β=0.12. The latter is designed to transport the beam coming out of the SC section of the linac to the beam dump, where the beam transverse profile is fairly enlarged and unformed to simplify the beam target design. The SC section consists of two cryomodules with 14 β=0.12 Spoke cavities, 14 solenoid and 14 BPMs in total. The first challenge in the physics design comes from the necessary space required for the cryomodule separation where the periodical lattice is destroyed at a relatively lower energy of ∼5  MeV. Another challenge is the beam dump line design, as it will be the first beam dump line being built by using a step field magnet for the transverse beam expansion and uniformity in the world. This paper gives an overview of the physics design study together with the design principles and machine construction considerations. The results of an optimized design, fabrication status and end to end simulations including machine errors are presented.

  6. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner.

    Science.gov (United States)

    Segal, Neil A; Bergin, John; Kern, Andrew; Findlay, Christian; Anderson, Donald D

    2017-02-01

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m2; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20° fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA.

  7. Test-retest reliability of tibiofemoral joint space width measurements made using a low-dose standing CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Segal, Neil A. [University of Kansas Medical Center, Department of Rehabilitation Medicine, 3901 Rainbow Boulevard, Mailstop 1046, Kansas City, KS (United States); The University of Iowa, Iowa City, IA (United States); Bergin, John; Kern, Andrew; Findlay, Christian [The University of Iowa, Iowa City, IA (United States); Anderson, Donald D. [The University of Iowa, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States)

    2017-02-15

    To determine the test-retest reliability of knee joint space width (JSW) measurements made using standing CT (SCT) imaging. This prospective two-visit study included 50 knees from 30 subjects (66% female; mean ± SD age 58.2 ± 11.3 years; BMI 29.1 ± 5.6 kg/m{sup 2}; 38% KL grade 0-1). Tibiofemoral geometry was obtained from bilateral, approximately 20 fixed-flexed SCT images acquired at visits 2 weeks apart. For each compartment, the total joint area was defined as the area with a JSW <10 mm. The summary measurements of interest were the percentage of the total joint area with a JSW less than 0.5-mm thresholds between 2.0 and 5.0 mm in each tibiofemoral compartment. Test-retest reliability of the summary JSW measurements was assessed by intraclass correlation coefficients (ICC 2,1) for the percentage area engaged at each threshold of JSW and root-mean-square errors (RMSE) were calculated to assess reproducibility. The ICCs were excellent for each threshold assessed, ranging from 0.95 to 0.97 for the lateral and 0.90 to 0.97 for the medial compartment. RMSE ranged from 1.1 to 7.2% for the lateral and from 3.1 to 9.1% for the medial compartment, with better reproducibility at smaller JSW thresholds. The knee joint positioning protocol used demonstrated high day-to-day reliability for SCT 3D tibiofemoral JSW summary measurements repeated 2 weeks apart. Low-dose SCT provides a great deal of information about the joint while maintaining high reliability, making it a suitable alternative to plain radiographs for evaluating JSW in people with knee OA. (orig.)

  8. Horizontal coring using air as the circulating fluid: Some prototype studies conducted in G Tunnel at the Nevada Test Site for the Yucca Mountain Project

    Energy Technology Data Exchange (ETDEWEB)

    Chornack, M.P. [Geological Survey, Las Vegas, NV (USA); French, C.A. [Reynolds Electrical and Engineering Co., Inc., Las Vegas, NV (USA)

    1989-12-31

    Horizontal coring using air as the circulating fluid has been conducted in the G Tunnel Underground Facility (GTUF) at the Nevada Test Site. This work is part of the prototype investigations of hydrogeology for the Yucca Mountain Project. The work is being conducted to develop methods and procedures that will be used at the Department of Energy`s Yucca Mountain Site, a candidate site for the nation`s first high-level nuclear waste repository, during the site characterization phase of the investigations. The United States Geological Survey (USGS) is conducting this prototype testing under the guidance of the Los Alamos National Laboratory (LANL) and in conjunction with Reynolds Electrical & Engineering Company (REECo), the drilling contractor. 7 refs., 8 figs., 5 tabs.

  9. The Role of Predictability in Saccadic Eye Responses in the Suppression Head Impulse Test of Horizontal Semicircular Canal Function

    Directory of Open Access Journals (Sweden)

    Jorge Rey-Martinez

    2017-10-01

    Full Text Available BackgroundIn the suppression head impulse paradigm (SHIMP vHIT protocol, the participant is instructed to follow with his gaze a mobile target generated by a laser placed on the participant’s head. Recent studies have reported that the refixation saccade latencies are in relation with the time evolution of the vestibular dysfunction in both (standard and SHIMP procedures. We hypothesized that some central mechanisms like head impulse prediction could be one of the causes for the differences in the saccadic eye responses.MethodsA prospective cohort non-randomized study was designed. For the SHIMP protocol, recorded with the ICS Impulse ver. 4.0® (Otometrics A/S, Taastrup, Denmark vHIT device, three different algorithms were performed: “predictable,” “less predictable,” and “unpredictable” depending on the target’s predictability. A mathematical method was developed to analyze the SHIMP responses. The method was implemented as an additional tool to the MATLAB open source script for the extended analysis of the vHIT responses named HITCal.ResultsIn cohort 1, 52 participants were included in “predictable” SHIMP protocol. In cohort 2, 60 patients were included for the “less predictable” and 35 patients for the “unpredictable” SHIMP protocol. The participants made more early saccades when instructed to perform the “predictable” paradigm compared with the “less predictable” paradigm (p < 0.001. The less predictable protocol did not reveal any significant difference when compared with the unpredictable protocol (p = 0.189. For the latency of the first saccade, there was statistical difference between the “unpredictable” and “predictable” protocols (p < 0.001 and between the “less predictable” and “predictable” protocols (p < 0.001. Finally, we did not find any relationship between the horizontal vestibulo-ocular reflex (hVOR gain and the latency of the saccades.ConclusionWe developed a

  10. Bafômetro positivo: correlatos do comportamento de beber e dirigir na cidade de Belo Horizonte, Minas Gerais, Brasil Alcoholímetro positivo: interrelación entre la conducta de beber y conducir en la ciudad de Belo Horizonte, Minas Gerais, Brasil Positive breathalyzer test: factors associated with drinking and driving in the city of Belo Horizonte, Minas Gerais State, Brazil

    Directory of Open Access Journals (Sweden)

    Valdir Ribeiro Campos

    2013-01-01

    Full Text Available As características dos condutores que adotam o comportamento do beber e dirigir ainda não foram bem estudadas no país. O presente estudo apresenta dados da prevalência e características dos motoristas sob a influência de álcool nas nove regionais da cidade de Belo Horizonte, Minas Gerais, Brasil. Foram entrevistados 1.656 condutores. Desses, 1.254 (76% aceitaram responder a um questionário estruturado e fazer o teste do bafômetro. O teste do bafômetro foi positivo para 15% dos condutores. O modelo de regressão logística prediz bafômetro positivo com chance 1,5 vez maior para os condutores com idade acima de 31 anos e 4,5 vezes maior para quem tem frequência de consumo de álcool pelo menos semanal. Além disso, condutores da regional Barreiro tem 2 vezes mais chances de apresentarem bafômetro positivo. Estudos localizados com metodologia dos postos de checagem da sobriedade podem monitorar o comportamento e características dos condutores, riscos no trânsito e direcionar políticas públicas para o beber e dirigir.Las características de los conductores que adoptan la conducta de beber y conducir todavía no han sido bien estudiadas en el país. El presente estudio muestra datos de la prevalencia y características de los conductores bajo la influencia de alcohol en las nueve carreteras regionales de la ciudad de Belo Horizonte, Minas Gerais, Brasil. Se entrevistaron a 1.656 conductores. De ellos, 1.254 (76% aceptaron responder a un cuestionario estructurado y hacer el test del alcoholímetro. El test del alcoholímetro fue positivo para un 15% de los conductores. El modelo de regresión logística predice un alcoholímetro positivo con una probabilidad 1,5 vez mayor para los conductores de edad por encima de los 31 años y 4,5 veces mayor para quien tiene una frecuencia de consumo de alcohol por lo menos semanal. Asimismo, conductores de la regional Barreiro tienen 2 veces más probabilidad de presentar positivo en el alcohol

  11. THE PROPOSAL OF A EVOLUTIONARY STRATEGY GENERATING THE DATA STRUCTURES BASED ON A HORIZONTAL TREE FOR THE TESTS

    Directory of Open Access Journals (Sweden)

    Marek ŻUKOWICZ

    2016-07-01

    Full Text Available The aim of the article is to present a mathematical definition of the object model, that is known in computer science as TreeList and to show application of this model for design evolutionary algorithm, that purpose is to generate structures based on this object. The first chapter introduces the reader to the problem of presenting data using the TreeList object. The second chapter describes the problem of testing data structures based on TreeList. The third one shows a mathematical model of the object TreeList and the parameters, used in determining the utility of structures created through this model and in evolutionary strategy, that generates these structures for testing purposes. The last chapter provides a brief summary and plans for future research related to the algorithm presented in the article.

  12. Tribological tests of wear-resistant coatings used in the production of drill bits of horizontal and inclined drilling

    Science.gov (United States)

    Maslov, A. L.; Markova, I. Yu; Zakharova, E. S.; Polushin, N. I.; Laptev, A. I.

    2017-05-01

    It is known that modern drilling bit body undergoes significant abrasive wear in the contact area with the solid and the retracted cuttings. For protection of the body rationally use wear-resistant coating, which is welded directly to the body of bit. Before mass use of the developed coverings they need to be investigated by various methods that it was possible to characterize coatings and on the basis of the obtained data to perform optimization of both composition of coatings and technology. Such methods include microstructural studies tribological tests, crack resistance and others. This work is devoted to the tribological tests of imported brand of coatings WokaDur NiA and and domestic brand of coating HR-6750 (both brands manufactured by Ltd “Oerlikon Metco Rus”), used to protect the bit body from abrasive wear.

  13. Erosion and break-up of light-gas layers by a horizontal jet in a multi-vessel, large-scale containment test system

    Energy Technology Data Exchange (ETDEWEB)

    Zboray, Robert, E-mail: robert.zboray@psi.ch; Mignot, Guillaume; Kapulla, Ralf; Paladino, Domenico

    2015-09-15

    The distribution and eventual stratification of hydrogen released during a hypothetical severe accident and the stability of the stratification formed in the early phase of the transient is of particular safety concern in Light Water Reactors (LWRs). The large-scale containment test facility PANDA (PSI, Switzerland) has been used to perform a series of four tests examining the erosion and break-up of stratified light-gas layers in the frame of the OECD SETH-2 project. The ultimate goal of the test program is to set-up an experimental data base of high-quality and high-density data that can challenge and validate 3D containment codes like e.g. GOTHIC, GASFLOW or MARS and validate the applicability of CFD codes like FLUENT or CFX for LWR containment problems. The test series discussed here focuses on the erosion of a stratified, helium-rich layer by horizontal steam injection at different locations below the layer. An approach with step-wise increasing complexity has been chosen to examine this problem allowing control over the rate of pressure increase and the occurrence of condensation. The step-wise approach enables a thorough understanding of the influence of different phenomena like position of steam injection, diffusion, pressurization and condensation on the behavior and erosion of the stratified layer.

  14. Performance and aerodynamic braking of a horizontal-axis wind turbine from small-scale wind tunnel tests

    Science.gov (United States)

    Cao, H. V.; Wentz, W. H., Jr.

    1987-01-01

    Wind tunnel tests of three 20" diameter, zero twist, zero pitch wind turbine rotor models were conducted in a 7' x 10' wind tunnel to determine the performance of such rotors with NACA 23024 and NACA 64 sub 3-621 airfoil sections. Aerodynamic braking characteristics of a 38% span, 30% chord, vented aileron configuration were measured on the NACA 23024 rotor. Surface flow patterns were observed using fluorescent mini-tufts attached to the suction side of the rotor blades. Experimental results with and without ailerons are compared to predictions using airfoil section data and a momentum performance code. Results of the performance studies show that the 64 sub 3-621 rotor produces higher peak power than the 23024 rotor for a given rotor speed. Analytical studies, however, indicate that the 23024 should produce higher power. Transition strip experiments show that the 23024 rotor is much more sensitive to roughness than the 64 sub 3-621 rotor. These trends agree with analytical predictions. Results of the aileron test show that this aileron, when deflected, produces a braking torque at all tip speed ratios. In free wheeling coastdowns the rotor blade stopped, then rotated backward at a tip speed ratio of -0.6.

  15. Performance and aerodynamic braking of a horizontal-axis wind turbine from small-scale wind tunnel tests

    Science.gov (United States)

    Cao, H. V.; Wentz, W. H., Jr.

    1987-07-01

    Wind tunnel tests of three 20" diameter, zero twist, zero pitch wind turbine rotor models were conducted in a 7' x 10' wind tunnel to determine the performance of such rotors with NACA 23024 and NACA 64 sub 3-621 airfoil sections. Aerodynamic braking characteristics of a 38% span, 30% chord, vented aileron configuration were measured on the NACA 23024 rotor. Surface flow patterns were observed using fluorescent mini-tufts attached to the suction side of the rotor blades. Experimental results with and without ailerons are compared to predictions using airfoil section data and a momentum performance code. Results of the performance studies show that the 64 sub 3-621 rotor produces higher peak power than the 23024 rotor for a given rotor speed. Analytical studies, however, indicate that the 23024 should produce higher power. Transition strip experiments show that the 23024 rotor is much more sensitive to roughness than the 64 sub 3-621 rotor. These trends agree with analytical predictions. Results of the aileron test show that this aileron, when deflected, produces a braking torque at all tip speed ratios. In free wheeling coastdowns the rotor blade stopped, then rotated backward at a tip speed ratio of -0.6.

  16. From concept to reality – A review to the primary test stand and its preliminary application in high energy density physics

    OpenAIRE

    Deng, Jianjun; Xie, Weiping; Feng, Shuping; Wang, Meng; Li, Hongtao; Song, Shengyi; Xia, Minghe; Ce, Ji; He, An; Tian, Qing; Gu, Yuanchao; Guan, Yongchao; Wei, Bin; Huang, Xianbin; Ren, Xiaodong

    2016-01-01

    Pulsed power technology, whereas the electrical energy stored in a relative long period is released in much shorter timescale, is an efficient method to create high energy density physics (HEDP) conditions in laboratory. Around the beginning of this century, China Academy of Engineering Physics (CAEP) began to build some experimental facilities for HEDP investigations, among which the Primary Test Stand (PTS), a multi-module pulsed power facility with a nominal current of 10 MA and a current ...

  17. Sourcebook of locations of geophysical surveys in tunnels and horizontal holes, including results of seismic refraction surveys, Rainier Mesa, Aqueduct Mesa, and Area 16, Nevada Test Site

    Science.gov (United States)

    Carroll, R.D.; Kibler, J.E.

    1983-01-01

    Seismic refraction surveys have been obtained sporadically in tunnels in zeolitized tuff at the Nevada Test Site since the late 1950's. Commencing in 1967 and continuing to date (1982), .extensive measurements of shear- and compressional-wave velocities have been made in five tunnel complexes in Rainier and Aqueduct Mesas and in one tunnel complex in Shoshone Mountain. The results of these surveys to 1980 are compiled in this report. In addition, extensive horizontal drilling was initiated in 1967 in connection with geologic exploration in these tunnel complexes for sites for nuclear weapons tests. Seismic and electrical surveys were conducted in the majority of these holes. The type and location of these tunnel and borehole surveys are indexed in this report. Synthesis of the seismic refraction data indicates a mean compressional-wave velocity near the nuclear device point (WP) of 23 tunnel events of 2,430 m/s (7,970 f/s) with a range of 1,846-2,753 m/s (6,060-9,030 f/s). The mean shear-wave velocity of 17 tunnel events is 1,276 m/s (4,190 f/s) with a range of 1,140-1,392 m/s (3,740-4,570 f/s). Experience indicates that these velocity variations are due chiefly to the extent of fracturing and (or) the presence of partially saturated rock in the region of the survey.

  18. Balance ability, not muscle strength and exercise endurance, determines the performance of hemiparetic subjects on the timed-sit-to-stand test.

    Science.gov (United States)

    Ng, Shamay

    2010-06-01

    To examine the contribution of balance ability, muscle strength, and exercise endurance to performance in the timed-sit-to-stand test among chronic hemiparetic subjects. A cross-sectional study with 68 community-dwelling stroke survivors. By using Pearson correlation coefficient, the five-times-sit-to-stand (FTSTS) test scores showed the highest negative correlation with Berg Balance Scale scores (r = -0.837, P test (r = -0.598, P Balance Scale scores only (r = -0.630, P balance confidence, showed that FTSTS scores were independently associated with Berg Balance Scale scores (beta = -0.630, P test were not significant predictors of FTSTS scores. The whole model could explain 71% of the variance in FTSTS scores. This is the first study documenting the importance of balance ability, not muscle strength and exercise endurance, as an important determinant of performance on the FTSTS test by community-dwelling stroke patients. These findings suggest that the FTSTS test may be a more appropriate proxy indicator of balance performance in chronic community-dwelling stroke subjects.

  19. Airborne Wear Particles Emissions ofCommercial Disc Brake Materials– Disc Brake Test Stand Simulations at LowContact Pressures and Rotors Pre-conditionedwith Rust

    OpenAIRE

    Wahlström, Jens; Olander, Lars; Olofsson, Ulf

    2008-01-01

    Most modern passenger cars have disc brakes on the front wheels, which unlike drum brakes are not sealed off to the ambient air. During braking, there is wear to both the rotor and the pads. This wear process generates particles, which may become airborne. A problem with measuring airborne wear particles in field tests is to distinguish them from the background noise. Therefore, a disc brake laboratory test stand that allows control of the cleanness of the surrounding air is used. With this t...

  20. Location of rut stands vs. mating opportunities in Przewalski’s gazelle: A field test of the “Resource-based Hypothesis” and “Female Traffic Version of the Hotspot Hypothesis”

    Directory of Open Access Journals (Sweden)

    Zhangqiang YOU, Zhigang JIANG, Chunwang LI

    2011-12-01

    Full Text Available We studied the mating tactics of Przewalski’s gazelle on the Qinghai-Tibetan Plateau from 2002 to 2005. Przewalski’s gazelle is a cluster mating animal whereby female groups, including juveniles, travel to and from their resting grounds along fixed routes and dominant males stand on or near these travel routes during rut. To explain rut patterns in male gazelles, we tested predictions arising from the “Resource-based Hypothesis” and “Female Traffic Version of the Hotspot Hypothesis”. We marked the location of each rut stand and female travel route, measured food availability in each rut stand and recorded the mating opportunities of rut stand owners. We also conducted a field experiment to force female groups to change their daily travel route, and observed whether males abandon their original rut stands and shift their rut stands to new travel routes of females during the 3rd rut. We found that: (1 male gazelle defending rut stands closer to a female travel route had a higher chance of mating; (2 food resources within rut stands had no effect on mating opportunities of the rut stand owner; (3 when the female travel route was obstructed, female groups changed grazing sites, and all males abandoned their original rut stands and defended new rut stands along the new female travel route. In conclusion, the location of rut stands in relation to female travel routes is the ultimate factor for consolidating mating opportunities in male gazelle, supporting the “Female Route Version of Hotspot Hypothesis” [Current Zoology 57 (6: 701–708, 2011].

  1. Using the Functional Reach Test for Probing the Static Stability of Bipedal Standing in Humanoid Robots Based on the Passive Motion Paradigm

    Directory of Open Access Journals (Sweden)

    Jacopo Zenzeri

    2013-01-01

    Full Text Available The goal of this paper is to analyze the static stability of a computational architecture, based on the Passive Motion Paradigm, for coordinating the redundant degrees of freedom of a humanoid robot during whole-body reaching movements in bipedal standing. The analysis is based on a simulation study that implements the Functional Reach Test, originally developed for assessing the danger of falling in elderly people. The study is carried out in the YARP environment that allows realistic simulations with the iCub humanoid robot.

  2. Large optics inspection, tilting, and washing stand

    Science.gov (United States)

    Ayers, Marion Jay [Brentwood, CA; Ayers, Shannon Lee [Brentwood, CA

    2010-08-24

    A large optics stand provides a risk free means of safely tilting large optics with ease and a method of safely tilting large optics with ease. The optics are supported in the horizontal position by pads. In the vertical plane the optics are supported by saddles that evenly distribute the optics weight over a large area.

  3. Large optics inspection, tilting, and washing stand

    Science.gov (United States)

    Ayers, Marion Jay; Ayers, Shannon Lee

    2012-10-09

    A large optics stand provides a risk free means of safely tilting large optics with ease and a method of safely tilting large optics with ease. The optics are supported in the horizontal position by pads. In the vertical plane the optics are supported by saddles that evenly distribute the optics weight over a large area.

  4. Validity and variability of the 5-repetition sit-to-stand test in patients with multiple sclerosis

    DEFF Research Database (Denmark)

    Møller, Andreas Buch; Bibby, Bo Martin; Guldhammer, Anders

    2012-01-01

    Purpose: To investigate; (i) the relationship between the 5STS-test and lower extremity muscle strength and balance, and (ii) the variability of the 5STS-test in multiple sclerosis (MS) patients. Method: 22 MS patients were divided into two groups (Group A and Group B) who completed one 5STS...

  5. Radiologically defining horizontal gaze using EOS imaging-a prospective study of healthy subjects and a retrospective audit.

    Science.gov (United States)

    Hey, Hwee Weng Dennis; Tan, Kimberly-Anne; Ho, Vivienne Chien-Lin; Azhar, Syifa Bte; Lim, Joel-Louis; Liu, Gabriel Ka-Po; Wong, Hee-Kit

    2017-10-18

    As sagittal alignment of the cervical spine is important for maintaining horizontal gaze, it is important to determine the former for surgical correction. However, horizontal gaze remains poorly-defined from a radiological point of view. The objective of this study was to establish radiological criteria to define horizontal gaze. This study was conducted at a tertiary health-care institution over a 1-month period. A prospective cohort of healthy patients was used to determine the best radiological criteria for defining horizontal gaze. A retrospective cohort of patients without rigid spinal deformities was used to audit the incidence of horizontal gaze. Two categories of radiological parameters for determining horizontal gaze were tested: (1) the vertical offset distances of key identifiable structures from the horizontal gaze axis and (2) imaginary lines convergent with the horizontal gaze axis. Sixty-seven healthy subjects underwent whole-body EOS radiographs taken in a directed standing posture. Horizontal gaze was radiologically defined using each parameter, as represented by their means, 95% confidence intervals (CIs), and associated 2 standard deviations (SDs). Subsequently, applying the radiological criteria, we conducted a retrospective audit of such radiographs (before the implementation of a strict radioimaging standardization). The mean age of our prospective cohort was 46.8 years, whereas that of our retrospective cohort was 37.2 years. Gender was evenly distributed across both cohorts. The four parameters with the lowest 95% CI and 2 SD were the distance offsets of the midpoint of the hard palate (A) and the base of the sella turcica (B), the horizontal convergents formed by the tangential line to the hard palate (C), and the line joining the center of the orbital orifice with the internal occipital protuberance (D). In the prospective cohort, good sensitivity (>98%) was attained when two or more parameters were used. Audit using Criterion B

  6. Three single leg standing tests for clinical assessment of chronic plantar heel pain syndrome: static stance, half-squat and heel rise.

    Science.gov (United States)

    Saban, B; Masharawi, Y

    2017-06-01

    To assess reliability and validity of three single leg standing clinical tests in patients with plantar heel pain syndrome (PHPS). Cross-sectional reliability study. Forty patients diagnosed with PHPS. Patients stood on their affected foot in a static stance for up to 30seconds, a half squat for up to 10 repetitions, and a heel rise for up to 10 repetitions. The first sensation of pain (p1) determined the termination of each test, and established a positive test result. The level of p1 was measured using a visual analogue scale (VAS); time or repetitions for each test were recorded. Prior to performing the tests, all patients completed the Foot & Ankle Computerized Adaptive Test to measure functional status (FS). Detection of p1 in each test showed good reliability for inter- and intrarater assessment (Kappa=0.60 to 0.78 and 0.56 to 0.77, respectively). The intraclass correlation coefficient for the VAS measures was 0.85 to 0.95 for inter-rater assessment and 0.78 to 0.92 for intrarater assessment. However, the Bland and Altman limits of agreement were wide, indicating that these measures were less reliable than the correlation coefficients suggested. Thirty-five patients (88%) experienced a positive pain response to at least one test. Significant correlations were found between the VAS measures in each test and FS (r=0.63 to 0.72). The static stance, half squat and heel rise tests were easily implemented, and found to be reliable and valid according to one analysis, yet less reliable with another, for pain provocation and VAS levels in patients with PHPS. All three VAS levels correlated well with FS. Copyright © 2016 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  7. Well test analysis of horizontal and deviated wells in the presence of cross-flow phenomenon and non-uniform depletion application to a field case : Hassi-Messaoud Oil Field Algeria

    Energy Technology Data Exchange (ETDEWEB)

    Mazouzi, A.; Azzouguen, A.; Bellah, S.; Hammad, K. [Sonatrach Inc., Hydra (Algeria)

    2001-06-01

    The crossflow theory was used to analyse a real transient test for a horizontal well in the Hassi-Messaoud field in Algeria. The software system used consisted of analytical equations for the cross flow phenomena. It was determined that crossflow plays an important role in layered reservoirs and that crossflow between layers should not be ignored. A newly proposed numerical model used here to analyse real transient test was found to be more realistic than an analytical model because the numerical model used distribution over an entire section. It was shown that total thickness, the skin of the layer containing the well and the permeable layers directly affect the early time and transient period. It was concluded that conventional analysis techniques do not work well for layered systems with horizontal wells.18 refs., 26 figs.

  8. Coxofemoral joint radiography in standing cattle.

    Science.gov (United States)

    Wenzinger, Beatrice; Hagen, Regine; Schmid, Tanja; Nuss, Karl

    2012-01-01

    The objective of this study was to establish a technique for radiographic examination of the coxofemoral joint and adjacent bony structures in standing cattle. Left (or right) 30° dorsal-right (or left) ventral radiographic views of the coxofemoral joint region of standing cattle (n = 10) with hind limb lameness were evaluated retrospectively. In addition, an experimental study of oblique laterolateral views of the coxofemoral joint region of a bovine skeleton at angles of 15-45° was carried out to determine the optimal position for visualization of the hip region. In the 10 clinical patients, the bodies of the ilium and ischium, the acetabulum and proximal third of the femur could be assessed. Six of these cattle had fractures of the body of the ilium and body of the ischium, five with and one without involvement of the acetabulum, two had craniodorsal and one caudoventral luxation of the femur and one had a femoral neck fracture. The described laterodorsal-lateroventral radiographs of the hip region in standing cattle were suitable for assessing the coxofemoral joint, the proximal aspect of the femur and parts of the ischium, ilium and pubis. After testing the optimal angle on the skeleton, it was seen that distortion and superimposition were minimized by positioning the X-ray beam at an angle of 25° to the horizontal plane. It can be concluded that the described technique improves the evaluation of injuries of the coxofemoral region in cattle. With the appropriate angle, the technique can also be applied in recumbent cattle. © 2012 Veterinary Radiology & Ultrasound.

  9. Imaging-based liver function tests. Past, present and future; Bildgestuetzte Leberfunktionstests. Stand der Technik und zukuenftige Entwicklungen

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, D.; Hamm, B.; Denecke, T. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Luedemann, L. [Essen University Hospital (Germany). Dept. of Medical Physics

    2015-10-15

    Preoperative assessment of liver function and prediction of postoperative functional reserve are important in patients scheduled for liver resection. While determination of absolute liver function currently mostly relies on laboratory tests and clinical scores, postoperative remnant liver function is estimated volumetrically using imaging data obtained with computed tomography (CT) or magnetic resonance imaging (MRI). Accurate estimation of hepatic function is also relevant for intensive care patients, oncologic patients, and patients with diffuse liver disease. The indocyanine green (ICG) test is still the only established test for estimating true global liver function. However, more recent tools such as the LiMAx test also allow global assessment of hepatic function. These tests are limited when liver function is inhomogeneously distributed, which is the case in such conditions as unilateral cholestasis or after portal vein embolization. Imaging-based liver function tests were first developed in nuclear medicine and, compared with laboratory tests, have the advantage of displaying the spatial distribution of liver function. Nuclear medicine scans are obtained using tracers such as 99mTc galactosyl and 99mTc mebrofenin. Liver function is typically assessed using planar scintigraphy. However, three-dimensional volumetry is possible with single-photon emission computed tomography (SPECT-CT). Another technique for image-based liver function estimation is Gd-EOB-enhanced MRI. While metabolization of Gd-EOB in the body is similar to that of ICG and mebrofenin, its distribution in the liver can be displayed by MRI with higher temporal and spatial resolution. Moreover, MRI-based determination of liver function can be integrated into routine preoperative imaging. This makes MRI an ideal candidate for preoperative determination of liver function, though the best pulse sequence and the parameter to be derived from the image information remain to be identified. Another

  10. Evaluation of the ICET Test Stand to Assess the Performance of a Range of Ceramic Media Filter Elements in Support of ASME AG-1 Subsection FO

    Energy Technology Data Exchange (ETDEWEB)

    Schemmel, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-04-26

    High Efficiency Particulate Air (HEPA) filters are defined as extended-medium, dry-type filters with: (1) a minimum particle removal efficiency of no less than 99.97 percent for 0.3 micrometer particles, (2) a maximum, clean resistance of 1.0 inch water column (in. WC) when operated at 1,000 cubic feet per minute (CFM), and (3) a rigid casing that extends the full depth of the medium. Specifically, ceramic media HEPA filters provide better performance at elevated temperatures, are moisture resistant and nonflammable, can perform their function if wetted and exposed to greater pressures, and can be cleaned and reused. This paper describes the modification and design of a large scale test stand which properly evaluates the filtration characteristics of a range of ceramic media filters challenged with a nuclear aerosol agent in order to develop Section FO of ASME AG-1.

  11. Development status of a test stand for semiconductor photocathodes with 60 keV spin-polarized beamline

    Energy Technology Data Exchange (ETDEWEB)

    Kurichijanil, Neeraj; Enders, Joachim; Espig, Martin; Fritzsche, Yuliya; Heichelt, Dominic; Kaiser, Andreas; Roesch, Heidi; Wagner, Markus [Institut fuer Kernphysik, TU Darmstadt (Germany)

    2016-07-01

    A test facility for Photo-Cathode Activation, Test and Cleaning using atomic-Hydrogen (Photo-CATCH) is being constructed at TU Darmstadt's Institute for Nuclear Physics (IKP) which houses the Superconducting Darmstadt Linear Accelerator (S-DALINAC). In order to improve the performance of the SDALINAC's photoelectron source based on GaAs, systematic studies in terms of quantum efficiency (QE), cathode rejuvenation, lifetimes and polarization (P) have to be conducted on different photocathode types. These factors strongly depend on handling of the cathode, the vacuum condition in the chambers, cathode surface cleaning as well as preservation of stoichiometry, negative electron affinity (NEA) activation of the cathode and the type and structure of the semiconductor material. With Photo-CATCH, experiments such as atomic-hydrogen cleaning, multi-alkali and oxidant NEA activation of the cathode and tests of QE, P and lifetimes can be performed in an improved vacuum. Additionally, experiments with polarized-electron beams of up to 60 keV are foreseen.

  12. The impact of various distance between axes of worm gear on torque value. Worm gear test stand

    Science.gov (United States)

    Sobek, M.; Baier, A.; Grabowski, Ł.

    2017-08-01

    Transferring both rotational and translational movements in systems used in the automotive industry is a very important and complex issue. In addition, the situation becomes much more difficult and complicated when the design of the transition system requires a high precision of operation as well as a well definite and long operating life. Such requirements are imposed on all components of today’s motor vehicles. However, particular attention is paid to the elements that directly or indirectly affect the safety of persons traveling in the vehicle. Such components are undoubtedly components included as parts of the steering system of the vehicle. Power steering systems have been present in motor vehicles for more than a century. They go through continuous metamorphosis and they are getting better and better. Current power steering systems are based on an electric motor and some kind of transmission. Depending on the position of the drive relative to the steering column, different configurations of the transmission are used. This article will cover issues related to tests of power steering gearing using a worm drive. The worm drive is a very specific example of a propulsion system that uses twisted axles. Normally, in this type of transition you can find two gear units with the axis mounted with a 90° angle between. The components of the worm drive are a worm and a worm gear, also called a worm wheel. In terms of the geometrical form, the worm resembles a helical spur gear. The shape of the worm is similar to the shape of a screw with a trapezoidal thread. A correct matching of these two components ensures proper operation of the entire transmission. Incorrect positioning of the components in relation to each other can significantly reduce the lifetime of the drive unit, and also lead to abnormal work, eg by raising the noise level. This article describes a test method of finding the appropriate distance between the axles of both worm drive units by testing the

  13. Adolescent standing postural response to backpack loads: a randomised controlled experimental study

    Directory of Open Access Journals (Sweden)

    Pirunsan Ubon

    2002-04-01

    Full Text Available Abstract Background Backpack loads produce changes in standing posture when compared with unloaded posture. Although 'poor' unloaded standing posture has been related to spinal pain, there is little evidence of whether, and how much, exposure to posterior load produces injurious effects on spinal tissue. The objective of this study was to describe the effect on adolescent sagittal plane standing posture of different loads and positions of a common design of school backpack. The underlying study aim was to test the appropriateness of two adult 'rules-of-thumb'-that for postural efficiency, backpacks should be worn high on the spine, and loads should be limited to 10% of body weight. Method A randomised controlled experimental study was conducted on 250 adolescents (12–18 years, randomly selected from five South Australian metropolitan high schools. Sagittal view anatomical points were marked on head, neck, shoulder, hip, thigh, knee and ankle. There were nine experimental conditions: combinations of backpack loads (3, 5 or 10% of body weight and positions (backpack centred at T7, T12 or L3. Sagittal plane photographs were taken of unloaded standing posture (baseline, and standing posture under the experimental conditions. Posture was quantified from the x (horizontal coordinate of each anatomical point under each experimental condition. Differences in postural response were described, and differences between conditions were determined using Analysis of Variance models. Results Neither age nor gender was a significant factor when comparing postural response to backpack loads or conditions. Backpacks positioned at T7 produced the largest forward (horizontal displacement at all the anatomical points. The horizontal position of all anatomical points increased linearly with load. Conclusion There is evidence refuting the 'rule-of-thumb' to carry the backpack high on the back. Typical school backpacks should be positioned with the centre at waist or

  14. Postural balance in low back pain patients: Intra-session reliability of center of pressure on a portable force platform and of the one leg stand test.

    Science.gov (United States)

    Maribo, Thomas; Stengaard-Pedersen, Kristian; Jensen, Lone Donbæk; Andersen, Niels Trolle; Schiøttz-Christensen, Berit

    2011-06-01

    Low back pain (LBP) patients have poorer postural control compared to healthy controls, and the importance of assessing and addressing balance is a matter of debate. In the clinic, balance is often tested by means of the one leg stand test (OLST) while research often employs center of pressure (CoP) on a force platform. Portable force platforms might be of clinical relevance, but their reliability for LBP patients in a clinical setting has not been demonstrated. As LBP patients are more dependent on vision compared to healthy controls, the ratio of tests performed with eyes open and eyes closed (Romberg Ratio) might be of clinical interest. This study aimed to assess postural balance in LBP patients by analyzing intra-session reliability of CoP parameters on a portable force platform, the Romberg Ratio, and the OLST. Furthermore, we aimed to determine whether CoP parameters and OLST measure identical aspects of postural stability. We examined 49 LBP patients and found acceptable reliability of the CoP parameters' trace length and velocity, whereas reliability regarding C90 area, the Romberg Ratio, and the OLST was poor. Correlations between the CoP parameters and OLST were insignificant. Reliability of trace length and velocity is acceptable and can be used as parameters when assessing CoP in LBP patients. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Control Performance of General Electric Fuel and Torque Regulator Operating on T31-3 Turbine-Propeller Engine in Sea-Level Test Stand

    Science.gov (United States)

    Oppenheimer, Frank L.; Lazar, James

    1951-01-01

    A .General Electric fuel and torque regulator was tested in conjunction with a T31-3 turbine-propeller engine in the sea-level static test stand at the NACA Lewis laboratory. The engine and control were operated over the entire speed range: 11,000 rpm, nominal flight idle, to 13,000 rpm, full power. Steady-state and transient data were recorded and are presented with a description of the four control loops being used in the system. Results of this investigation indicated that single-lever control operation was satisfactory under conditions of test. Transient data presented showed that turbine-outlet temperature did overshoot maximum operating value on acceleration but that the time duration of overshoot did not exceed approximately 1 second. This temperature limiting resulted from a control on fuel flow as a function of engine speed. Speed and torque first reached their desired values 0.4 second from the time of change in power-setting lever position. Maximum speed overshoot was 3 percent.

  16. Stability and Capsize оf Free-Standing Hydrotank: Development of Trial Tanks to Test Underwater Robots

    Directory of Open Access Journals (Sweden)

    S. P. Severov

    2015-01-01

    Full Text Available The problem of capsizing object, which are free-supported under the forces of gravity, elasticity, friction, and other unpredictably changing external influences, is a global challenge for the civil engineering and for transport (air, road, rail, and others. Much of the research activities on capsizing the free-supported objects of the certain types are fragmentarily included in the different subject areas of technical applications. In particular, it is typical for a hydrotank that is a thin-walled shell-type liquid-filled container. The hydrotank problems are multiple structural, geometric and natural forms of nonlinearity. The aim of this study is to determine the phase and the critical parameters of the basic objects of simple shape with different supporting plane: cube; box; cylinder etc., pouring the fluid, with or without shell. Hydrotank capsize as a solid body with a fluid is analysed and as a first approximation this analysis precedes the assessment of stability of the object as a hydroelastic system. The experimental results prove the possibility to design, manufacture and use this type of hydrotanks to test underwater robots. The work gives more undestanding on the studied problem and on the sphere wherein results can be efficiently implemented.

  17. Determination of the optimal cutoff time to use when screening elderly people for locomotive syndrome using the one-leg standing test (with eyes open).

    Science.gov (United States)

    Seichi, Atsushi; Hoshino, Yuichi; Doi, Tokuhide; Akai, Masami; Tobimatsu, Yoshiko; Kita, Kiyoshi; Iwaya, Tsutomu

    2014-07-01

    To establish the cutoff time for the one-leg standing (OLS) test (with eyes open) to use when screening elderly people for locomotive syndrome. Patients visiting orthopedic clinics and healthy volunteers, all ≥65 years old, were recruited. Participants were asked to complete the 25-question Geriatric Locomotive Function Scale (GLFS-25) and then underwent the OLS test. Using the previously determined GLFS-25 cutoff value, participants were divided into two groups: the locomotive and the non-locomotive syndrome groups (GLFS-25 scores of ≥16 and 70 and ≤75, and aged >75), we determined the optimal cutoff value for IA-OLS time for each of the three age groups using ROC analysis. According to additional ROC analysis, the optimal cutoff for IA-OLS time was 19 s for individuals aged ≤70, 10 s for individuals aged >70 and ≤75, and 6 s for individuals aged >75 when screening elderly persons for locomotive syndrome. We propose using a GLFS-25 score of 16 and/or a cutoff for the IA-OLS time of 19 s for individuals aged ≤70, 10 s for individuals aged >70 and ≤75, and 6 s for individuals aged >75 when screening elderly persons to determine who should receive medical intervention or undergoing training programs.

  18. [The balance function of the patients with benign paroxysmal positional vertigo during standing].

    Science.gov (United States)

    Zhou, Renhong; Liu, Bo; Zhang, Sulin; Liu, Dongdong; Liu, Jingjing; Leng, Yangming; Kong, Weijia

    2015-11-01

    The purpose of the study was to investigate the balance function of the patients with benign paroxysmal positional vertigo (BPPV) during standing. In this study 41 patients with posterior semicircular canal BPPV (PC BPPV) and 11 patients with horizontal semicircular canal BPPV (HC BPPV) were recruited. Dynamic balance during standing was measured in Sensory Organization Test (SOT). Static balance during standing was measured in modified Clinical Test of Sensory Interaction and Balance (mCTSIB). Data of BPPV patients were compared to that from 44 normal controls. Scores of the patients with PC BPPV were lower than that of the normal controls in the last three test conditions of SOT. Patients with PC BPPV demonstrated greater sway velocity in stance on foam with eyes open and eyes closed in mCTSIB. No postural deficit was observed in neither SOT nor mCTSIB when the patients with HC BPPV were compared to the normal controls. Disorders of the horizontal semicircular canal do not influence postural control. Both dynamic and static posturography can detect the postural imbalance caused by posterior semicircular canal dysfunction.

  19. INTRODUCING NOVEL GENERATION OF HIGH ACCURACY CAMERA OPTICAL-TESTING AND CALIBRATION TEST-STANDS FEASIBLE FOR SERIES PRODUCTION OF CAMERAS

    OpenAIRE

    M. Nekouei Shahraki; N. Haala

    2015-01-01

    The recent advances in the field of computer-vision have opened the doors of many opportunities for taking advantage of these techniques and technologies in many fields and applications. Having a high demand for these systems in today and future vehicles implies a high production volume of video cameras. The above criterions imply that it is critical to design test systems which deliver fast and accurate calibration and optical-testing capabilities. In this paper we introduce new generation o...

  20. Belo Horizonte em recortes

    Directory of Open Access Journals (Sweden)

    Ivete Lara Camargos Walty

    1998-03-01

    Full Text Available A partir do conceito de rizoma de Deleuze e Guatari, faz-se uma montagem de trechos de textos literários sobre Belo Horizonte, intercalados com extratos do livro As cidades invisíveis, de Italo Calvino, como objetivo de se esboçar faces/retratos da cidade.

  1. Horizontal violence in Nursing

    Directory of Open Access Journals (Sweden)

    Tsimoulaki Evangelia

    2017-01-01

    Full Text Available One’s effort to clarify the definition of horizontal labour violence is of great importance, due to the variety of definitions that are mentioned in the worldwide scientific literature. Furthermore, the reference of multiple forms of such violence herein the nurse professional group is challenging, as well. Another fact of great importance is that, any form of professional violence (horizontal violence, horizontal mobbing in the work place environment can be possibly escalated and include even physical abuse (Bullying, besides the psychological and emotional impact for the victim. The definitions of Horizontal violence, Mobbing and Bullying, include a repeated negative behaviour emanating from at least one “predator” towards at least one “victim”, with work status differences and the existence or lack of physical abuse (Bullying. Horizontal violence is a hostile, aggressive and harmful behaviour which is either overt or concealed and is pointed from an individual to another individual of the same working rank and causes intense emotional pain at the victim. The manifestations vary from humiliating tasks assignment or the victim’s efforts undermining to clearly aggressive behaviors (criticism, intimidation, sarcasm etc.. The reason behind this phenomenon is multifactorial extended not only towards the working environment but also to the personal characteristics of the “predator” as well as the possible “victim”. The researchers emphasize the high incidence of the phenomenon, as well as the cost that is induced by the violent behaviors to both the health professionals and the hospital. Finally, they point out the paradox of the presence of violence inside a system that is designed to promote health.

  2. From concept to reality – A review to the primary test stand and its preliminary application in high energy density physics

    Directory of Open Access Journals (Sweden)

    Jianjun Deng

    2016-01-01

    Full Text Available Pulsed power technology, whereas the electrical energy stored in a relative long period is released in much shorter timescale, is an efficient method to create high energy density physics (HEDP conditions in laboratory. Around the beginning of this century, China Academy of Engineering Physics (CAEP began to build some experimental facilities for HEDP investigations, among which the Primary Test Stand (PTS, a multi-module pulsed power facility with a nominal current of 10 MA and a current rising time ∼90 ns, is an important achievement on the roadmap of the electro-magnetically driven inertial confinement fusion (ICF researches. PTS is the first pulsed power facility beyond 10 TW in China. Therefore, all the technologies have to be demonstrated, and all the engineering issues have to be overcome. In this article, the research outline, key technologies and the preliminary HEDP experiments are reviewed. Prospects on HEDP research on PTS and pulsed power development for the next step are also discussed.

  3. Horizontal drilling activity in Manitoba

    Energy Technology Data Exchange (ETDEWEB)

    Fox, J.

    1997-04-01

    An update of horizontal well drilling in Manitoba was provided. Manitoba`s productive formations are: (1) the Bakken Formation, (2) the Lodgepole Formation, (3) the Mission Canyon Formation, (4) the Amaranth Formation, and (5) the Melita Formation. A total of 28 exploratory wells and 29 development wells, including 11 horizontal wells were drilled in 1996. The 11 horizontal wells accounted for 30 per cent of the drilling meterage. The leading drillers for horizontal wells in Manitoba are Tundra Oil and Gas, Chevron, Anderson and HCO. Production from horizontal wells in 1996 totaled 310 cubic meter per day. To date, no horizontal wells have been drilled in the Bakken Formation. The least successful horizontal well application has been in the Lodgepole Formation. A summary of horizontal well production was provided for each Formation. 4 tabs., 10 figs.

  4. Out-standing!

    DEFF Research Database (Denmark)

    Kural, René

    2013-01-01

    Out-standing concerns the Danish tennisplayer Leif Rovsing and his outstanding piece of architecture Danish Tennis Club in Hellerup.......Out-standing concerns the Danish tennisplayer Leif Rovsing and his outstanding piece of architecture Danish Tennis Club in Hellerup....

  5. Stand-alone Inverter: Reviews, Models and Tests the exist system in Term of the Power Quality, and Suggestions to Design it

    Directory of Open Access Journals (Sweden)

    Ali Algaddafi

    2016-10-01

    Full Text Available Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM inverters, notably for obtaining electricity from renewable systems. This paper critical review the previous studies in designing stand-alone inverter and modelling the inverter with two control loops to improve and provide a high-quality power of a stand-alone inverter. Multi-loop control techniques for a stand-alone inverter are utilised as the first loop is a capacitor current control to provide active damping and improve transient and steady state inverter performance. The capacitor current control is cheaper than inductor current control, where a small current sensing resistor is used. The second loop is the output voltage control that is used to improve the system performance and also control the output voltage. The power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the grid. The suggestions and key findings to design the stand-alone inverter are given based in the reviewing of previous publications and from the literature’s point of view.

  6. The use of computed tomography scans and the Bender Gestalt Test in the assessment of competency to stand trial and criminal responsibility in the field of mental health and law.

    Science.gov (United States)

    Mosotho, Nathaniel Lehlohonolo; Timile, Ino; Joubert, Gina

    computed tomography and the Bender Gestalt Test are some of the tests used routinely for the assessment of alleged offenders referred under Sections 77 and 78 of the Criminal Procedure Act 51 of 1977. An exploratory retrospective study was conducted at the Free State Psychiatric Complex. The aim of this study was to identify the extent to which the Bender Gestalt Test results and the computed tomography scans are associated with outcomes in the assessment of competency to stand trial and criminal responsibility in individuals referred to the Free State Psychiatric Complex (FSPC) observation unit. This was a cross-sectional study and the entire population of patients admitted in 2013 was included in the study. The clinical and demographic data were obtained from patient files. The majority of participants were black, males, single and unemployed. The most common diagnosis was schizophrenia. The current study showed no statistically significant association between the Bender Gestalt Test Hain's scores and the outcome of criminal responsibility and competency to stand trial. Similarly, the study also showed no statistically significant association between the presence of a brain lesion and the outcome of criminal responsibility and competency to stand trial. It was also concluded that as CT scans are expensive, patients should be referred for that service only when there is a clear clinical indication to do so. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Determining the ion temperature and energy distribution in a lithium-plasma interaction test stand with a retarding field energy analyzer

    Science.gov (United States)

    Christenson, M.; Stemmley, S.; Jung, S.; Mettler, J.; Sang, X.; Martin, D.; Kalathiparambil, K.; Ruzic, D. N.

    2017-08-01

    The ThermoElectric-driven Liquid-metal plasma-facing Structures (TELS) experiment at the University of Illinois is a gas-puff driven, theta-pinch plasma source that is used as a test stand for off-normal plasma events incident on materials in the edge and divertor regions of a tokamak. The ion temperatures and resulting energy distributions are crucial for understanding how well a TELS pulse can simulate an extreme event in a larger, magnetic confinement device. A retarding field energy analyzer (RFEA) has been constructed for use with such a transient plasma due to its inexpensive and robust nature. The innovation surrounding the use of a control analyzer in conjunction with an actively sampling analyzer is presented and the conditions of RFEA operation are discussed, with results presented demonstrating successful performance under extreme conditions. Such extreme conditions are defined by heat fluxes on the order of 0.8 GW m-2 and on time scales of nearly 200 μs. Measurements from the RFEA indicate two primary features for a typical TELS discharge, following closely with the pre-ionizing coaxial gun discharge characteristics. For the case using the pre-ionization pulse (PiP) and the theta pinch, the measured ion signal showed an ion temperature of 23.3 ± 6.6 eV for the first peak and 17.6 ± 1.9 eV for the second peak. For the case using only the PiP, the measured signal showed an ion temperature of 7.9 ± 1.1 eV for the first peak and 6.6 ± 0.8 eV for the second peak. These differences illustrate the effectiveness of the theta pinch for imparting energy on the ions. This information also highlights the importance of TELS as being one of the few linear pulsed plasma sources whereby moderately energetic ions will strike targets without the need for sample biasing.

  8. The one-leg standing radiograph

    Science.gov (United States)

    Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis was evaluated using the joint space width and Kellgren-Lawrence (KL) radiographic classification. The t-test was used for statistical analysis. Results The mean medial joint space width found in the one-leg and in the both-legs standing view were measured at 1.8 mm and 2.4 mm, respectively (p leg standing views, respectively. No changes for KL IV osteoarthritis diagnoses have been found between both- and one-leg standing views. Conclusions One-leg standing radiographs better represent joint space width than both-legs standing radiographs. 32% of both-legs standing radiographs have changed the KL grading to a more severe grade than that in the one-leg standing radiographs. Cite this article: P. Pinsornsak, K. Naratrikun, S. Kanitnate, T. Sangkomkamhang. The one-leg standing radiograph: An improved technique to evaluate the severity of knee osteoarthritis. Bone Joint Res 2016;5:436–441. DOI: 10.1302/2046-3758.59.BJR-2016-0049.R1. PMID:27683299

  9. HORIZONTAL BOILING REACTOR SYSTEM

    Science.gov (United States)

    Treshow, M.

    1958-11-18

    Reactors of the boiling water type are described wherein water serves both as the moderator and coolant. The reactor system consists essentially of a horizontal pressure vessel divided into two compartments by a weir, a thermal neutronic reactor core having vertical coolant passages and designed to use water as a moderator-coolant posltioned in one compartment, means for removing live steam from the other compartment and means for conveying feed-water and water from the steam compartment to the reactor compartment. The system further includes auxiliary apparatus to utilize the steam for driving a turbine and returning the condensate to the feed-water inlet of the reactor. The entire system is designed so that the reactor is self-regulating and has self-limiting power and self-limiting pressure features.

  10. PRODUCTIVITY OF FRACTURED HORIZONTAL WELLS

    Directory of Open Access Journals (Sweden)

    Stjepan Antolović

    2009-12-01

    Full Text Available The interest and performance of horizontal drilling and completions has increased during the last two decades. Horizontal wells are advantageous compared to vertical wells in thin reservoirs, reservoirs with favorable vertical permeability and reservoirs with water and gas coning problems. In many reservoirs, the ratio of horizontal permeability to the vertical permeability is substantially larger than one and often is close to 10. Thus, these reservoirs are very good candidates for hydraulic fracturing. By hydraulic fracturing one or more fractures are created, which can be longitudinal or orthogonal. By that, flow is altered and it mostly conducts horizontally through reservoir toward horizontal wellbore. With this altered flow, fluid is produced faster, with less pressure loss by fluid unit of produced fluid. Some of the existing mathematical models to determine the productivity of multifractured horizontal wells are presented in this work (the paper is published in Croatian.

  11. Vertical and Horizontal Jump Capacity in International Cerebral Palsy Football Players.

    Science.gov (United States)

    Reina, Raul; Iturricastillo, Aitor; Sabido, Rafael; Campayo-Piernas, Maria; Yanci, Javier

    2017-11-28

    the aims of the present study were to evaluate the reliability and validity of vertical and horizontal jump tests in football players with cerebral palsy (FPCP), and to analyze the jump performance differences between current IFCPF functional classes (i.e. FT5-FT8). One hundred and thirty-two international para-footballers (25.8 ± 6.7 years; 70.0 ± 9.1 kg; 175.7 ± 7.3 cm; 22.8 ± 2.8 kg·m-2; 10.7 ± 7.5 years training experience) participated in the study. The participants were classified according to the IFCPF Classification Rules (i.e. FT5-FT8), and a group of 39 players without CP was included in the study as a control group (CG). Football players' vertical and horizontal jump performance was assessed. All the tests showed good to excellent relative intra-session reliability scores, both in FPCP and in the CG (ICC=.78-.97, SEMjump (CMJ), standing broad jump (SBJ), four bounds for distance (4B), triple hop for distance dominant leg (THd) and non-dominant leg (THnd). The CG performed higher/farther jumps with regard to all the FPCP classes, obtaining significant differences and moderate to large effect sizes (.85jump tests compared to players in the lower classes (ES=moderate to large, pjump tests performed in this study could be applied to the classification procedures and protocols for cerebral palsy football players.

  12. Coldbox installation for HL-LHC crab cavity test in the SPS tunnel (BA6)

    CERN Document Server

    Ordan, Julien Marius

    2018-01-01

    The Cold-box, produced by Linde Kryotechnik for the SPS crab-cavity test stand for HL-LHC, on its arrival at CERN. It wll be transported into the tunnel in horizontal position and then will have to be tilted in its operational position, on its vertical axis, before connecting it to cryogenics lines.

  13. [Difference of body movements accompanying mandibular movements in standing and sitting positions].

    Science.gov (United States)

    Takeuchi, Satoshi; Kohno, Shoji; Kobayashi, Hiroshi; Sakurai, Naoki; Hosogai, Akiko; Kinjoh, Atsushi; Kai, Asako

    2008-10-01

    To assess whether body movement accompanying jaw movement exists even in sitting position, and, if so, to investigate differences of body movements in the sitting and standing positions. The subjects were six men (age, 25-29 years, mean, 27.0 years) without stomatognathic problems. During the measurements, their Camper's planes were kept horizontal. One measurement sequence consisted of 20 s of tapping preceded and followed by 10 s of intercuspation. Mandibular movements (lower incisor point) were measured by referring to a coordinate system located on the maxilla, and head movements (upper incisor, condyle, etc) with TRIMETII (Tokyo Sizaisya) and body movements (sternum point) in sagittal plane were measured by referring to a coordinate system located on the floor with Proreflex (Qualisys). Body movements accompanying jaw movements were detected even in sitting position. The ratio of body movements to jaw movements was significantly larger in standing position than in sitting position using Wilcoxon matched-pairs signed-rank test. Peak power of body movement at corresponding frequency to the open-close movement was significantly larger in standing position than in sitting position using Wilcoxon matched-pairs signed-rank test. On the other hand, there was no difference between sitting and standing position in probability of body movement detection by the original wave analysis using Wilcoxon matched-pairs signedrank test. Body movements accompanying jaw movements were detected even in sitting position, and were smaller than in standing position. However, the probability of movements detected in original wave had no difference between the positions. Thus we concluded that we can analyze body movements during mastication in natural sitting position.

  14. Evaluation of horizontal magnification on panoramic images

    Directory of Open Access Journals (Sweden)

    Maryam Raoof

    2013-01-01

    Full Text Available Aims: This study evaluated the horizontal magnification of images taken from adults and pediatrics with PM 2002 CC Planmeca analogue machine. Materials and Methods: A series of 120 panoramic radiographs were obtained of 60 adults and 60 pediatrics. For all patients, negative impressions were used to make positive casts of the teeth. A caliper was used to measure the maximum mesiodistal length of the buccal surface of all teeth except canines on both casts and radiographs. The horizontal magnification factor was calculated for incisor, premolar, and molar regions by dividing the values obtained from the casts by the values obtained from the radiographs. Statistical Analysis: Independent t-test and one-way analysis of variance (ANOVA were used. Results: The results indicated that with regard to adults, maxillary and mandibular incisor regions, unlike the other two sessions, didn′t show significant difference of the mean magnification of horizontal dimension (P = 0.5. In pediatrics, the comparison between mean magnification factors of all subgroups showed significant difference (P < 0.0001. Despite the adults′ radiographs, the results of pediatrics′ radiographs showed significantly higher magnification than the index listed by the manufacturer of the radiographic machine used. Conclusion: The present study results point to the fact that PM 2002 CC Proline panoramic machine makes possible precise measurements on radiographs of adults′ jaws in the horizontal dimension.

  15. [Can a newly-established test for assessing standing and balance function be an alternative to the timed up-and-go test?--functional assessment of gait and balance in elderly patients for a comprehensive geriatric assessment initiative named 'Dr. SUPERMAN'].

    Science.gov (United States)

    Otoguro, Motohide; Ohnuma, Takeshi; Hirao, Kentarou; Iwamoto, Toshihiko

    2012-01-01

    To identify elderly patients who are at high risk for falls, we used the timed up-and-go test (TUG) as an assessment tool for gait and balance function in a comprehensive geriatric assessment (CGA) initiative named 'Dr. SUPERMAN'. However, this test is difficult to perform in a small area because it requires at least 3 meters of movement space. Therefore, we investigated whether another, newly-developed test, based on the Berg balance test, could be an alternative to the TUG test. We enrolled a total of 99 eligible subjects out of 105 elderly patients with disorders such as Alzheimer disease, Parkinson disease, cerebral infarction, osteoporosis and vascular risk factors, and administered the TUG test and the newly-developed standing and balance test (SBT). Of these 99, 6 patients could not stand independently. While the time to accomplish TUG was determined, any unsteadiness during TUG was also recorded. The SBT consists of 3 components: standing up independently, standing on a narrow base for 15 seconds without any swaying of the trunk, and a timed one-leg standing test (TOLS) for 15 seconds on both sides. Taking more than 14 seconds to accomplish the TUG or abnormal unsteadiness during the test was defined as positive, and each cut-off point was measured on the TOLS, with or without swaying of the trunk. The time to accomplish TUG significantly increased with age, and positive TUG findings were observed in 43 subjects. The mean TOLS time significantly and suddenly worsened at over 75 years of age, including among those subjects who showed swaying of the trunk and who could only perform the TOLS for less than 1 second. The receiver operating curve indicated that a TOLS cut-off point of less than 3 seconds, together with standing with help or swaying of the trunk during the SBT, most efficiently determined a positive TUG score, with high sensitivity (86%), high specificity (87.5%), and a high positive predictive value (84.1%). In a narrow space, the SBT can

  16. Kneeling and standing up from a chair as performance-based tests to evaluate knee function in the high-flexion range: a randomized controlled trial comparing a conventional and a high-flexion TKA design.

    Science.gov (United States)

    van der Ven, Paul J P; van de Groes, Sebastiaan; Zelle, Jorrit; Koëter, Sander; Hannink, Gerjon; Verdonschot, Nico

    2017-08-01

    We compared the functional outcome between conventional and high-flexion total knee arthroplasty (TKA) using kneeling and sit-to-stand tests at 1 year post-operative. In addition, the patient's daily functioning, pain and satisfaction were quantified using questionnaires. We randomly assigned 56 patients to receive either a conventional or a high-flexion TKA. Primary outcomes were maximum flexion angle and maximum thigh-calf contact measured during kneeling at 1 year post operatively. Secondary outcomes were the angular knee velocity and ground reaction force ratio measured during sit-to-stand performance tests, and questionnaires. At one year post-operative, maximum knee flexion during kneeling was higher for the high-flexion TKA group (median 128.02° (range 108-146)) compared to the conventional TKA group (119.13° (range 72-135)) (p = 0.03). Maximum thigh-calf contact force was higher for the high flexion TKA group (median 17.82 N (range 2.98-114.64)) compared to the conventional TKA group (median 9.37 N (range 0.33-46.58))(p = 0.04). The sit-to-stand tests showed a significantly higher angular knee velocity in the conventional TKA group (12.12 rad/s (95%CI 0.34-23.91); p = 0.04). There were no significant differences between groups in ground reaction force ratios and patient-reported outcome scores. Although no differences were found in patient-reported outcome scores, differences in performance-based tests were clearly apparent. Standing up from a chair at 90° of knee flexion appeared to be easier for the conventional group. The kneeling test revealed significantly higher weight-bearing knee flexion for the high-flex group. Hence, if kneeling is an important activity for a patient a high-flex design may be recommendable. The study was retrospectively registered in ClinicalTrials.gov under identifier NCT00899041 (date of registration: May 11, 2009).

  17. Forest Stand Age

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — Source data for forest stand age were obtained from the USDA Forest Inventory and Analysis (FIA) DataMart and were projected for future scenarios based on selected...

  18. Horizontal and Vertical Line Designs.

    Science.gov (United States)

    Johns, Pat

    2003-01-01

    Presents an art lesson in which students learn about the artist Piet Mondrian and create their own abstract artworks. Focuses on geometric shapes using horizontal and vertical lines. Includes background information about the artist. (CMK)

  19. Notes on the horizontal cohomology

    OpenAIRE

    Verbovetsky, Alexander

    1998-01-01

    This paper is devoted to the horizontal (``characteristic'') cohomology of systems of differential equations. Recent results on computing the horizontal cohomology via the compatibility complex are generalized. New results on the Vinogradov C-spectral sequence and the Krasil'shchik C-cohomology are obtained. As an application of general theory, the examples of an evolution equation and a p-form gauge theory are explicitly worked out.

  20. Mechanisms of Horizontal Gene Transfer

    OpenAIRE

    Cafini Barrado, Fabio; Medrano Romero, Verónica; Morikawa, Kazuya

    2017-01-01

    Horizontal gene transfer plays important roles in the evolution of S. aureus, and indeed, a variety of virulence factors and antibiotic resistance genes are embedded in a series of mobile genetic elements. In this chapter, we review the mechanisms of horizontal gene transfer, including recent findings on the natural genetic competence. Then, we consider the transfer of two important antibiotic resistance genes: the methicillin resistance gene, mecA (in Staphylococcal Cassette Chromosome) and ...

  1. Buoyancy Driven Natural Ventilation through Horizontal Openings

    DEFF Research Database (Denmark)

    Heiselberg, Per; Li, Zhigang

    2009-01-01

    An experimental study of the phenomenon of buoyancy driven natural ventilation through single-sided horizontal openings was performed in a full-scale laboratory test rig. The measurements were made for opening ratios L/D ranging from 0.027 to 4.455, where L and D are the length of the opening...... and the diameter of the opening, respectively. The basic nature of airflow through single-sided openings, including airflow rate, air velocity, temperature difference between the rooms and the dimensions of the horizontal openings, were measured. A bi-directional airflow rate was measured using the constant...... quite well with the Epstein's formula but in other cases the measured data show clear deviations from the Epstein's formula. Thus, revised formulas for natural ventilation are proposed....

  2. Buoyancy Driven Natural Ventilation through Horizontal Openings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    2009-01-01

    An experimental study of the phenomenon of buoyancy driven natural ventilation through single-sided horizontal openings was performed in a full-scale laboratory test rig. The measurements were made for opening ratios L/D ranging from 0.027 to 4.455, where L and D are the length of the opening...... and the diameter of the opening, respectively. The basic nature of airflow through single-sided openings, including airflow rate, air velocity, temperature difference between the rooms and the dimensions of the horizontal openings, were measured. A bi-directional airflow rate was measured using the constant...... quite well with the Epstein's formula ratio are presented. In some cases the measured airflow rates fit quite well with the Epstein's formula but in other cases the measured data show clear deviations from the Epstein's formula. Thus, revised formulas for natural ventilation are proposed....

  3. The standing heel-rise test: relation to chronic venous disorders and balance, gait, and walk time in injection drug users.

    Science.gov (United States)

    Pieper, Barbara; Templin, Thomas N; Birk, Thomas J; Kirsner, Robert S

    2008-09-01

    Injection drug use can impair mobility. When mobility is impaired in combination with other potential pathologic changes to the veins, muscles, and joints of the lower legs, chronic venous disorders can develop. The heel-rise test, an assessment of eccentric-concentric muscle action of calf muscle function with regard to plantar flexion, can be used to measure ankle mobility. To examine the test-retest reliability and construct validity of the heel-rise test in relation to chronic venous disorders in persons with a history of injection drug use (N = 104), a test-retest study (M = 45.9+/-12.9 days from first to second test) was conducted. Participants were assessed for chronic venous disorders of the legs and walk time; they also completed the heel-rise and Tinetti Balance and Gait tests. Test-retest reliability was found to be good for full heel rise of right and left legs (ICC = .66 and .67, respectively). Heel-rise performance was positively correlated with balance (r = .38 to .47) and gait (r = .38 to .45) and negatively related to walk time (r = -.30 to -.35) (P test as a measure of calf muscle function is supported by these results, implicating the role of mobility restriction in the etiology of venous disease. Although more research is needed regarding its performance, the heel-rise test may be a low-cost, noninvasive screening or assessment tool in a variety of outpatient settings.

  4. DRILL BITS FOR HORIZONTAL WELLS

    Directory of Open Access Journals (Sweden)

    Paolo Macini

    1996-12-01

    Full Text Available This paper underlines the importance of the correct drill bit application in horizontal wells. Afler the analysis of the peculiarities of horizontal wells and drainholes drilling techniques, advantages and disadvantages of the application of both roller cone and fixed cutters drill bits have been discussed. Also, a review of the potential specific featuries useful for a correct drill bit selection in horizontal small diameter holes has been highlighted. Drill bits for these special applications, whose importance is quickly increasing nowadays, should be characterised by a design capable to deliver a good penetration rate low WOB, and, at the same time, be able to withstand high RPM without premature cutting structure failure and undergauge. Formation properties will also determine the cutting structure type and the eventual specific features for additional gauge and shoulder protection.

  5. Nuclear component horizontal seismic restraint

    Science.gov (United States)

    Snyder, Glenn J.

    1988-01-01

    A nuclear component horizontal seismic restraint. Small gaps limit horizontal displacement of components during a seismic occurrence and therefore reduce dynamic loadings on the free lower end. The reactor vessel and reactor guard vessel use thicker section roll-forged rings welded between the vessel straight shell sections and the bottom hemispherical head sections. The inside of the reactor guard vessel ring forging contains local vertical dovetail slots and upper ledge pockets to mount and retain field fitted and installed blocks. As an option, the horizontal displacement of the reactor vessel core support cone can be limited by including shop fitted/installed local blocks in opposing alignment with the reactor vessel forged ring. Beams embedded in the wall of the reactor building protrude into apertures in the thermal insulation shell adjacent the reactor guard vessel ring and have motion limit blocks attached thereto to provide to a predetermined clearance between the blocks and reactor guard vessel ring.

  6. Nurses’ Perceptions of Horizontal Violence

    Directory of Open Access Journals (Sweden)

    Rosemary Taylor

    2016-04-01

    Full Text Available In this article, I describe a study exploring horizontal violence and nurses’ perceptions of the phenomenon within the context of two 28-bed inpatient hospital units. The purpose of the study was to develop a clearer understanding of horizontal violence, incorporating observation and inquiry to identify the language nurses use to describe their experiences and factors in the nursing work environment that may perpetuate the phenomenon. Observation, review and analysis of policies, and interviews with staff were completed between June and November 2012. Thematic analysis resulted in five themes: (a behaviors are minimized and not recognized, (b fear inhibits all reporting, (c avoidance and isolation are coping strategies, (d lack of respect and support, and (e organizational chaos. The findings suggest future interventions must address a range of factors that perpetuate horizontal violence within the nursing work environment with consideration for the embeddedness and complexity of the phenomenon.

  7. Effect of testing position on dynamic visual acuity.

    Science.gov (United States)

    Danenbaum, Elizabeth; Chilingaryan, Gevorg; Fung, Joyce

    2008-12-01

    To investigate the effect of altering testing position on dynamic visual acuity (DVA) in vestibulopathic adults. Quasiexperimental research. Outpatient vestibular program. Twelve vestibulopathic adults with impaired DVA in the sitting position. DVA scores were collected during (1) sitting, (2) standing comfortably, and (3) semitandem standing as subjects viewed a vision (E) chart 3.48 m in front of them. DVA was obtained as the head was passively moved by the evaluator at a frequency of 1.5 Hz in both horizontal and vertical directions. A further subgroup of subjects (n=5) was retested after performing the "viewing x1" gaze stability home exercise four times daily (1 minute duration in the horizontal direction while sitting) for 2 months. Noncomputerized DVA score. The DVA score remained constant independent of testing position as the Friedman test did not reveal any significant differences in the DVA scores in the horizontal or vertical direction. Subjects who improved after performing the viewing x1 exercise in the horizontal direction in the sitting position tended to have the same improvement in DVA in all three positions. The results of this study show that DVA score is independent of testing position. This is clinically important since it shows that the results of DVA testing in one position are valid for other positions and that subjects can be trained to improve their DVA in a sitting posture while having carry-over effects to other, more challenging postures.

  8. Principles of managing stands

    Science.gov (United States)

    David A. Marquis; Rodney Jacobs

    1989-01-01

    Forest stands are managed to achieve some combination of desired products or values. These products or values may include income and tangible benefits from timber production or fees for hunting rights and other recreational activities. The values may be intangible, such as the enjoyment of seeing wildlife or flowering plants, or the simple satisfaction of knowing that...

  9. STAND AT EASE

    African Journals Online (AJOL)

    Abel

    for what was described as “national service”. While books like these are not exactly flooding the shelves of bookstores, they roll of the presses more regularly now. These works mostly deal with ex-conscript's that actively experienced the war in. Namibia and Angola. Stand at ease is different: there is no "cordite and conflict".

  10. Economics of stand management

    Science.gov (United States)

    David K. Lewis

    1986-01-01

    This paper sets out to demonstrate the importance of considering the wealth represented by the growing stock in economic analyses of stand management alternatives, and to demonstrate the role of thinning in the manipulation of the efficiency of growing stock in the management of shortleaf pine (Pinus echinata Mill.). These goals are achieved through a demonstration of...

  11. Golden rule (standing theology)

    OpenAIRE

    Ellis, Randolph

    2017-01-01

    This study offers an example of ‘standing theology’ as distinguished from sitting theology or kneeling theology. The occasion was the Fourth Sunday of Easter in Bangor Cathedral, 2015. The Epistle reading was 1 John 3: 16–24.\\ud \\ud

  12. Standing on the Shoulders of Giants? Exploring Consensus on the Validity Status of Mintzberg’s Configuration Theory After a Negative Test

    Directory of Open Access Journals (Sweden)

    Tommy Krabberød

    2015-10-01

    Full Text Available This article explores the degree of consensus on the validity status of Mintzberg’s configuration theory following a test in which the theory was refuted. The 218 articles that have cited the award-winning article by Doty, Glick, and Huber, and 89 articles and 12 books published by Mintzberg after the test, are reviewed. None of the reviewed articles contained any discussion about the implications for Mintzberg’s theory. It is then discussed whether the test was exhaustive and whether the lack of debate should be interpreted as tacit agreement with Doty et al. Normative aspects of a silent research community are also discussed. It is argued that it has not been proved beyond reasonable doubt that the test is exhaustive and that there are sociological explanations for the lack of debate other than “silence implies agreement.” Finally, it is argued that it would have been fruitful if the test had stirred debate.

  13. Speckle Imaging Over Horizontal Paths

    Energy Technology Data Exchange (ETDEWEB)

    Carrano, C J

    2002-05-21

    Atmospheric aberrations reduce the resolution and contrast in surveillance images recorded over horizontal or slant paths. This paper describes our recent horizontal and slant path imaging experiments of extended scenes as well as the results obtained using speckle imaging. The experiments were performed with an 8-inch diameter telescope placed on either a rooftop or hillside and cover ranges of interest from 0.5 km up to 10 km. The scenery includes resolution targets, people, vehicles, and other structures. The improvement in image quality using speckle imaging is dramatic in many cases, and depends significantly upon the atmospheric conditions. We quantify resolution improvement through modulation transfer function measurement comparisons.

  14. In-Plume Emission Test Stand 2: Emission Factors for 10- to 100-kW U.S. Military Generators

    Science.gov (United States)

    2009-12-01

    EC/OC Filter samples were analyzed by gravimetry, ion chroma- tography, X-ray fluorescence, colorimetry , and thermal/ optical reflectance (TOR).53,54... multiple parameters including engine size, engine load, unit age, and total running hours. The aver- age CO EF of generators tested was 5% lower, and...in Figure 4. Filter samples inte- grated results from a full test cycle or multiple engines in the case of cold starts. On average, the ELPI-simulated

  15. Members of the team responsable for the strength test stand on the plug for the main CMS shaft on which 2500 tonnes of steel blocks have been placed

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The plug over the CMS shaft, which will be required to bear the weight of the various detector sub-assemblies when they are lowered into the experiment hall, has just passed a strength test. The plug, a huge 2.2-metre-thick rectangular block of reinforced concrete measuring 15 x 20 metres and weighing 2000 tonnes, underwent its first strength test on 15 May.

  16. Standing on the Shoulders of Giants? Exploring Consensus on the Validity Status of Mintzberg’s Configuration Theory After a Negative Test

    OpenAIRE

    Tommy Krabberød

    2015-01-01

    This article explores the degree of consensus on the validity status of Mintzberg’s configuration theory following a test in which the theory was refuted. The 218 articles that have cited the award-winning article by Doty, Glick, and Huber, and 89 articles and 12 books published by Mintzberg after the test, are reviewed. None of the reviewed articles contained any discussion about the implications for Mintzberg’s theor...

  17. Cleanup/stimulation of a horizontal wellbore using propellants

    Energy Technology Data Exchange (ETDEWEB)

    Rougeot, J.E.; Lauterbach, K.A.

    1993-01-01

    This report documents the stimulation/cleanup of a horizontal well bore (Wilson 25) using propellants. The Wilson 25 is a Bartlesville Sand well located in the Flatrock Field, Osage County, Oklahoma. The Wilson 25 was drilled to determine if horizontal drilling could be used as a means to economically recover primary oil that had been left in place in a mostly abandoned oil field because of the adverse effects of water coning. Pump testing of the Wilson 25 horizontal well bore before cleanup or stimulation produced 6 barrels of oil and .84 barrels of water per day. The high percentage of daily oil production to total daily fluid production indicated that the horizontal well bore had accessed potentially economical oil reserves if the fluid production rate could be increased by performing a cleanup/stimulation treatment. Propellants were selected as an inexpensive means to stimulate and cleanup the near well bore area in a uniform manner. The ignition of a propellant creates a large volume of gas which penetrates the formation, creating numerous short cracks through which hydrocarbons can travel into the well bore. More conventional stimulation/cleanup techniques were either significantly more expensive, less likely to treat uniformly, or could not be confined to the near well bore area. Three different propellant torpedo designs were tested with a total of 304' of horizontal well bore being shot and producible. The initial test shot caused 400' of the horizontal well bore to become plugged off, and subsequently it could not be production tested. The second and third test shots were production tested, with the oil production being increased 458% and 349%, respectively, on a per foot basis. The Wilson 25 results indicate that a propellant shot treatment is an economically viable means to cleanup/stimulate a horizontal well bore.

  18. Transitioning couple's voluntary HIV counseling and testing (CVCT from stand-alone weekend services into routine antenatal and VCT services in government clinics in Zambia's two largest cities.

    Directory of Open Access Journals (Sweden)

    Mubiana Inambao

    Full Text Available Most HIV infections in Africa are acquired by married/cohabiting adults and WHO recommends couple's voluntary HIV counseling and testing (CVCT for prevention. The handover from NGO-sponsored weekend CVCT to government-sponsored services in routine weekday antenatal care (ANC and individual voluntary testing and counseling (VCT services in Zambia's two largest cities from 2009-2015 is described.Government clinic counselors were trained to provide CVCT, and along with community health workers they promoted CVCT services in their clinic and surrounding areas. When client volume exceeded the capacity of on-duty staff in ANC and VCT, non-governmental organization (NGO subsidies were offered for overtime pay.Implementation of routine CVCT services varied greatly by clinic and city. The 12 highest volume clinics were examined further, while 13 clinics had CVCT numbers that were too low to warrant further investigation. In Lusaka, the proportion of pregnant women whose partners were tested rose from 2.6% in 2009 to a peak of 26.2% in 2012 and 24.8% in 2015. Corresponding reports in Ndola were 2.0% in 2009, 17.0% in 2012 and 14.5% in 2015. Obstacles to CVCT included: limited space and staffing, competing priorities, record keeping not adapted for couples, and few resources for promotion and increasing male involvement. Conflicting training models for 'partner testing' with men and women separately vs. CVCT with joint post-test counseling led to confusion in reporting to district health authorities.A focused and sustained effort will be required to reach a meaningful number of couples with CVCT to prevent heterosexual and perinatal HIV transmission. Establishing targets and timelines, funding for dedicated and appropriately trained staff, adoption of standardized data recording instruments with couple-level indicators, and expansion of community and clinic-based promotions using proven models are recommended.

  19. Transitioning couple's voluntary HIV counseling and testing (CVCT) from stand-alone weekend services into routine antenatal and VCT services in government clinics in Zambia's two largest cities.

    Science.gov (United States)

    Inambao, Mubiana; Kilembe, William; Canary, Lauren A; Czaicki, Nancy L; Kakungu-Simpungwe, Matilda; Chavuma, Roy; Wall, Kristin M; Tichacek, Amanda; Pulerwitz, Julie; Thior, Ibou; Chomba, Elwyn; Allen, Susan A

    2017-01-01

    Most HIV infections in Africa are acquired by married/cohabiting adults and WHO recommends couple's voluntary HIV counseling and testing (CVCT) for prevention. The handover from NGO-sponsored weekend CVCT to government-sponsored services in routine weekday antenatal care (ANC) and individual voluntary testing and counseling (VCT) services in Zambia's two largest cities from 2009-2015 is described. Government clinic counselors were trained to provide CVCT, and along with community health workers they promoted CVCT services in their clinic and surrounding areas. When client volume exceeded the capacity of on-duty staff in ANC and VCT, non-governmental organization (NGO) subsidies were offered for overtime pay. Implementation of routine CVCT services varied greatly by clinic and city. The 12 highest volume clinics were examined further, while 13 clinics had CVCT numbers that were too low to warrant further investigation. In Lusaka, the proportion of pregnant women whose partners were tested rose from 2.6% in 2009 to a peak of 26.2% in 2012 and 24.8% in 2015. Corresponding reports in Ndola were 2.0% in 2009, 17.0% in 2012 and 14.5% in 2015. Obstacles to CVCT included: limited space and staffing, competing priorities, record keeping not adapted for couples, and few resources for promotion and increasing male involvement. Conflicting training models for 'partner testing' with men and women separately vs. CVCT with joint post-test counseling led to confusion in reporting to district health authorities. A focused and sustained effort will be required to reach a meaningful number of couples with CVCT to prevent heterosexual and perinatal HIV transmission. Establishing targets and timelines, funding for dedicated and appropriately trained staff, adoption of standardized data recording instruments with couple-level indicators, and expansion of community and clinic-based promotions using proven models are recommended.

  20. Variation in terminology: capoeira in Belo Horizonte

    Directory of Open Access Journals (Sweden)

    César Nardelli Cambraia

    2014-12-01

    Full Text Available In this pilot study we analyzed the variation in the terminology of capoeira in Belo Horizonte. The terms referring to 69 videotaped movements of capoeira were collected from 10 informants (5 men and 5 women, aged between 25 and 32 years, capoeira teachers. As a result we obtained 294 different terms whose patterns of variation are distributed among 15 types. We tested the hypothesis that the figurative terms tend to be replaced by non-figurative ones, and it was confirmed by the collected data. This trend was the result of a search for transparency in terminology, making the terms more descriptive in relation to capoeira’s movements.

  1. Vertical and horizontal spheroidal boundary-value problems

    Science.gov (United States)

    Šprlák, Michal; Tangdamrongsub, Natthachet

    2017-12-01

    Vertical and horizontal spheroidal boundary-value problems (BVPs), i.e., determination of the external gravitational potential from the components of the gravitational gradient on the spheroid, are discussed in this article. The gravitational gradient is decomposed into the series of the vertical and horizontal vector spheroidal harmonics, before being orthogonalized in a weighted sense by two different approaches. The vertical and horizontal spheroidal BVPs are then formulated and solved in the spectral and spatial domains. Both orthogonalization methods provide the same analytical solutions for the vertical spheroidal BVP, and give distinct, but equivalent, analytical solutions for the horizontal spheroidal BVP. A closed-loop simulation is performed to test the correctness of the analytical solutions, and we investigate analytical properties of the sub-integral kernels. The systematic treatment of the spheroidal BVPs and the resulting mathematical equations extend the theoretical apparatus of geodesy and of the potential theory.

  2. Some Considerations on Horizontal Displacement and Horizontal Displacement Coefficient B

    Directory of Open Access Journals (Sweden)

    Tajduś Krzysztof

    2015-12-01

    Full Text Available Mining-induced deformations of the ground surface and within the rock mass may pose danger not only for surface constructions but also for underground objects (e.g., tunnels, underground storages, garages, diverse types of pipelines, electric cables, etc. For a proper evaluation of hazard for surface and underground objects, such parameters as horizontal displacement and horizontal deformations, especially their maximum values, are of crucial importance. The paper is an attempt at a critical review of hitherto accomplished studies and state of the art of predicting horizontal displacement u, in particular the coefficient B, whose value allows determination of the value of maximum displacement if the value of maximum slope is known, or the value of maximum deformation if the value of maximum trough slope is recognized. Since the geodesic observations of fully developed subsidence troughs suggest that the value of the coefficient depends on the depth H, radius of main influences range r and properties of overburden rock, in particular the occurrence of sub-eras Paleogene and Neogene layers (old name: Quaternary and Tertiary with low strength parameters, therefore a formula is provided in the present paper allowing for the estimation of the influence of those factors on the value of coefficient B.

  3. Laboratórios de análises e patologia clínica em Belo Horizonte, MG (Brasil: classificação quanto ao atendimento e exames realizados Clinical pathology laboratories in Belo Horizonte, Minas Gerais: classification according to service and tests carried out

    Directory of Open Access Journals (Sweden)

    Carlos M. F. Antunes

    1985-02-01

    Full Text Available Foi efetuada uma classificação, quanto ao atendimento e exames realizados, dos laboratórios de análises e patologia clínica operando na região metropolitana de Belo Horizonte, MG (Brasil, em 1978. Foram comparadas as 3 categorias de laboratórios (particulares, institucionais e hospitalares, segundo tipos de exames realizados, clientela atendida e pessoal técnico responsável pelos laboratórios. Com base nos resultados obtidos na análise, foi composto um "perfil" típico para cada categoria de laboratório estudado.An assessment of the Clinical Pathology Laboratories in Belo Horizonte, MG, was carried out in 1978, and the 3 categories identified (Private, Institutional and Hospital were compared in relation to the types of exams performed, to the clientele and to the Laboratories' personnel. Based on the results obtained, a typical "profile" for each category studied was drawn up.

  4. The role of forest stand structure as biodiversity indicator

    DEFF Research Database (Denmark)

    Gao, Tian; Hedblom, Marcus; Emilsson, Tobias

    2014-01-01

    species composition and canopy stratification. Using data from the National Inventory of Landscapes in Sweden and General Linear Mixed Model, plant species diversity (Shannon diversity index, SHDI) and composition (Sørensen-Dice index, SDI) were tested between 26 different stand structure types and nine...... be achieved if indicators are derived from existing data. In this study, a model for classifying forest stand structures was developed and tested as an indicator of overall plant species diversity at stand level. The model combines four stand structure parameters: canopy coverage, age of canopy trees, tree...

  5. "They should know where they stand": attitudes to HIV Voluntary Counselling and testing amongst a group of out-of-school youth

    Directory of Open Access Journals (Sweden)

    Dennis Francis

    2010-01-01

    Full Text Available This article draws on a larger study that examined the ways in which out-of-school youth responded to a context of HIV/AIDS and how they themselves can be active participants in HIV/AIDS prevention. In addition, four out-of-school youths, trained as fieldworkers, interviewed 32 other out-of-school youths in the Shongweni area of KwaZulu-Natal about their attitudes towards VCT. The out-of-school youth displayed a very positive attitude towards VCT and 91% stated their intentions of getting tested. However this attitude was contradicted by the facts that only nine (28% had been for testing and that participants evidenced high levels of fear and stigma surrounding VCT. Of the participants, 43% stated a preference for a VCT site or hospital far from home, or, if they could afford it, a private doctor, to minimise the likelihood of being seen by someone they knew. This factor made it more difficult and costlier for outof-school youth to access VCT. For some, the fear of HIV infection is caught up with their existing social exclusion. In contrast, one reason for wanting to test amongst girls was the health of future children. While out-of-school youth understood the role of VCT in maintaining a healthy lifestyle, the obstacles to acting on those intentions included the context of poverty, gender inequalities, stigma and the fear of gossip. Campaigns have succeeded in raising awareness, but translating awareness into action remains a central problem.

  6. In-situ Curing Strain Monitoring of a Flat Plate Residual Stress Specimen Using a Chopped Stand Mat Glass/Epoxy Composite as Test Material

    Science.gov (United States)

    Jakobsen, J.; Skordos, A.; James, S.; Correia, R. G.; Jensen, M.

    2015-12-01

    The curing stresses in a newly proposed bi-axial residual stress testing configuration are studied using a chopped strand mat glass/epoxy specimen. In-situ monitoring of the curing is conducted using dielectric and fibre Bragg grating sensors. It is confirmed that a bi-axial residual stress state can be introduced in the specimens during curing and a quantification of its magnitude is presented. An alternative decomposition method used for converting the dielectric signal into a material state variable is proposed and good agreement with models found in the literature is obtained. From the cure cycles chosen it is suggested that any stress build up in the un-vitrified state is relaxed immediately and only stress build up in the vitrified state contributes to the residual stress state in the specimen.

  7. Learning to Stand: The Acceptability and Feasibility of Introducing Standing Desks into College Classrooms

    Directory of Open Access Journals (Sweden)

    Roberto M. Benzo

    2016-08-01

    Full Text Available Prolonged sedentary behavior is an independent risk factor for multiple negative health outcomes. Evidence supports introducing standing desks into K-12 classrooms and work settings to reduce sitting time, but no studies have been conducted in the college classroom environment. The present study explored the acceptability and feasibility of introducing standing desks in college classrooms. A total of 993 students and 149 instructors completed a single online needs assessment survey. This cross-sectional study was conducted during the fall semester of 2015 at a large Midwestern University. The large majority of students (95% reported they would prefer the option to stand in class. Most students (82.7% reported they currently sit during their entire class time. Most students (76.6% and instructors (86.6% reported being in favor of introducing standing desks into college classrooms. More than half of students and instructors predicted having access to standing desks in class would improve student’s “physical health”, “attention”, and “restlessness”. Collectively, these findings support the acceptability of introducing standing desks in college classrooms. Future research is needed to test the feasibility, cost-effectiveness and efficacy of introducing standing desks in college classrooms. Such studies would be useful for informing institutional policies regarding classroom designs.

  8. Standing equine dental surgery.

    Science.gov (United States)

    Menzies, Robert A; Easley, Jack

    2014-04-01

    Dental surgeries refer to procedures that affect the dental tissues or their supporting structures. With the development of specific, efficacious, and conservative treatments, morbidity risks have been lowered and chances of benefiting the health of equids improved. Advances in quality of sedation, analgesia, and locoregional anesthesia allow a majority of dental surgeries to be performed in the standing patient. This update focuses on an orthograde endodontic technique, a minimally invasive buccotomy technique, with the potential to combine it with a transbuccal screw extraction technique, and revisits the AO pinless external fixator for fractures of the body of the mandible. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. A Case Study of Modern PLC and LabVIEW Controls: Power Supply Controls for the ORNL ITER ECH Test Stand

    Energy Technology Data Exchange (ETDEWEB)

    Barker, Alan M [ORNL; Killough, Stephen M [ORNL; Bigelow, Tim S [ORNL; White, John A [ORNL; Munro Jr, John K [ORNL

    2011-01-01

    Power Supply Controls are being developed at Oak Ridge National Laboratory (ORNL) to test transmission line components of the Electron Cyclotron Heating (ECH) system, with a focus on gyrotrons and waveguides, in support of the International Thermonuclear Experimental Reactor (ITER). The control is performed by several Programmable Logic Controllers (PLC s) located near the different equipment. A technique of Supervisory Control and Data Acquisition (SCADA) is presented to monitor, control, and log actions of the PLC s on a PC through use of Allen Bradley s Remote I/O communication interface coupled with an Open Process Control/Object Linking and Embedding [OLE] for Process Control (OPC) Server/Client architecture. The OPC data is then linked to a National Instruments (NI) LabVIEW system for monitoring and control. Details of the architecture and insight into applicability to other systems are presented in the rest of this paper. Future integration with an EPICS (Experimental Physics Industrial Control System) based mini-CODAC (Control, Data Access and Communication) SCADA system is under consideration, and integration considerations will be briefly introduced.

  10. Human balance responses to perturbations in the horizontal plane.

    Science.gov (United States)

    Fritschi, Michael; Jelinek, Herbert F; McGloughlin, Tim; Khalaf, Kinda; Khandoker, Ahsan H; Vallery, Heike

    2014-01-01

    Human balance strategies during standing have been studied extensively. Most of these studies rely on perturbations to the feet, for example by moving platforms or treadmills, and focus on the sagittal plane. Less research has been done on reactions to perturbations to the upper body, and the direction dependence of stabilizing strategies is still an open question. Here, we describe an experiment where we apply horizontal static pulling forces to the upper body of standing human subjects in different directions by means of an overhead robotic device, the FLOAT. Based on a simplified mechanical model, we propose the normalized displacement of the center of pressure, the ΔCoPn, as a measure of the selected balance strategy. We find that existing neuromechanical models do not fully explain responses to these static horizontal forces, because they predict too much CoP movement. Further, we found a tendency to particularly reduce CoP movement in anterior-posterior direction, indicating that reconfiguration of the body may play a larger role in this direction.

  11. Is the 1-minute sit-to-stand test a good tool for the evaluation of the impact of pulmonary rehabilitation? Determination of the minimal important difference in COPD

    Directory of Open Access Journals (Sweden)

    Vaidya T

    2016-10-01

    Full Text Available Trija Vaidya,1,2 Claire de Bisschop,2 Marc Beaumont,3,4 Hakima Ouksel,5 Véronique Jean,6 François Dessables,7 Arnaud Chambellan,1,8 On behalf of IRSR RéhaEffort cohort group 1Explorations Fonctionnelles Respiratoires, l’institut du thorax, CHU de Nantes, 2Université de Poitiers, Laboratoire MOVE EA 6314, F-86000 Poitiers, 3Pulmonary Rehabilitation Unit, Morlaix Hospital Centre, 4European University of Occidental Brittany, EA3878, Brest, 5Service de Pneumologie, CHU d’Angers, Angers, 6Service de Réhabilitation Respiratoire, Soins de Suite et Rééducation, CHU de Nantes, 7Service de Réhabilitation Respiratoire, la Tourmaline, UGECAM, 8Université de Nantes, Laboratory EA 4334 “Mouvement, Interactions, Performance,” Nantes, France Background: The 1-minute sit-to-stand (STS test could be valuable to assess the level of exercise tolerance in chronic obstructive pulmonary disease (COPD. There is a need to provide the minimal important difference (MID of this test in pulmonary rehabilitation (PR.Methods: COPD patients undergoing the 1-minute STS test before PR were included. The test was performed at baseline and the end of PR, as well as the 6-minute walk test, and the quadriceps maximum voluntary contraction (QMVC. Home and community-based programs were conducted as recommended. Responsiveness to PR was determined by the difference in the 1-minute STS test between baseline and the end of PR. The MID was evaluated using distribution and anchor-based methods.Results: Forty-eight COPD patients were included. At baseline, the significant predictors of the number of 1-minute STS repetitions were the 6-minute walk distance (6MWD (r=0.574; P<10-3, age (r=-0.453; P=0.001, being on long-term oxygen treatment (r=-0.454; P=0.017, and the QMVC (r=0.424; P=0.031. The multivariate analysis explained 75.8% of the variance of 1-minute STS repetitions. The improvement of the 1-minute STS repetitions at the end of PR was 3.8±4.2 (P<10-3. It was mainly

  12. Lift performance and lumbar loading in standing and seated lifts.

    Science.gov (United States)

    Middleton, Kane J; Carstairs, Greg L; Ham, Daniel J

    2016-09-01

    This study investigated the effect of posture on lifting performance. Twenty-three male soldiers lifted a loaded box onto a platform in standing and seated postures to determine their maximum lift capacity and maximum acceptable lift. Lift performance, trunk kinematics, lumbar loads, anthropometric and strength data were recorded. There was a significant main effect for lift effort but not for posture or the interaction. Effect sizes showed that lumbar compression forces did not differ between postures at lift initiation (Standing 5566.2 ± 627.8 N; Seated 5584.0 ± 16.0) but were higher in the standing posture (4045.7 ± 408.3 N) when compared with the seated posture (3655.8 ± 225.7 N) at lift completion. Anterior shear forces were higher in the standing posture at both lift initiation (Standing 519.4 ± 104.4 N; Seated 224.2 ± 9.4 N) and completion (Standing 183.3 ± 62.5 N; Seated 71.0 ± 24.2 N) and may have been a result of increased trunk flexion and a larger horizontal distance of the mass from the L5-S1 joint. Practitioner Summary: Differences between lift performance and lumbar forces in standing and seated lifts are unclear. Using a with-in subjects repeated measures design, we found no difference in lifted mass or lumbar compression force at lift initiation between standing and seated lifts.

  13. Panspermia and horizontal gene transfer

    Science.gov (United States)

    Klyce, Brig

    2009-08-01

    Evidence that extremophiles are hardy and ubiquitous is helping to make panspermia a respectable theory. But even if life on Earth originally came from space, biologists assume that the subsequent evolution of life is still governed by the darwinian paradigm. In this review we show how panspermia could amend darwinism and point to a cosmic source for, not only extremophiles but, all of life. This version of panspermia can be called "strong panspermia." To support this theory we will discuss recent evidence pertaining to horizontal gene transfer, viruses, genes apparently older than the Earthly evolution of the features they encode, and primate-specific genes without identifiable precursors.

  14. Standing Concertation Committee

    CERN Multimedia

    HR Department

    2009-01-01

    Ordinary Meeting on 11 May 2009 The meeting of the Standing Concertation Committee held on 11 May 2009 was entirely dedicated to the preparation of the TREF meeting on 19 & 20 May 2009. The Committee took note, discussed and agreed on some clarifications on a number of documents and presentations that the Management planned to submit and/or present to TREF on the following subjects: • Personnel statistics 2008: J. Purvis presented the Personnel Statistics for 2008 prepared by HR Department. In line with the previous year, key messages were firstly, a general reduction in staff (2544 to 2400, - 6%), secondly, a reduction in administrative services personnel (from 422 to 387, - 8%) and thirdly, a marked increase in the number of Users and Unpaid Associates (from 8369 to 9140, + 9%) • Five-Yearly Review 2010: A series of draft documents were submitted for discussion, comprising an introductory document explaining the statutory basis for the following four document...

  15. STANDING CONCERTATION COMMMITTEE

    CERN Multimedia

    HR Department

    2008-01-01

    ORDINARY MEETING ON 27 FEBRUARY 2008 The main items discussed at the meetings of the Standing Concertation Committee on 27 February 2008 included: Short-term Saved Leave Scheme The committee noted that, by the end of February 2008, some 600 staff had subscribed to the short-term saved leave scheme: approx 58% had subscribed 1 slice, 14% two slices, 5% three slices and 23% four slices. Administrative Circular No. 4 (Rev. 4) - Unemployment Insurance Scheme The committee agreed to recommend Administrative Circular No. 4 (Rev. 4) - Unemployment Insurance Scheme to the Director-General for approval. Administrative Circular No. 30 (Rev. 2) - Financial benefits upon taking up appointment and termination of contract The committee agreed to recommend Administrative Circular No. 30 (Rev. 2) - Financial Benefits upon taking up appointment and termination of contract to the Director-General for approval. Progressive Retirement Programme The Progressive Retirement Programme (PRP) was extended for a further year to 3...

  16. Standing Concertation Committee

    CERN Multimedia

    HR Department

    2008-01-01

    ORDINARY MEETING ON 27 FEBRUARY 2008 The main items discussed at the meetings of the Standing Concertation Committee on 27 February 2008 included: Short-term Saved Leave Scheme The Committee noted that, by the end of February 2008, some 600 staff had enrolled in the short-term saved leave scheme: approx. 58% had signed up for 1 slice, 14% for two slices, 5% for three slices and 23% for four slices. Administrative Circular No. 4 (Rev. 4) - Unemployment Insurance Scheme The Committee agreed to recommend the Director-General to approve Administrative Circular No. 4 (Rev. 4) - Unemployment Insurance Scheme. Administrative Circular No. 30 (Rev. 2) - Financial benefits upon taking up appointment and termination of contract The Committee agreed to recommend the Director-General to approve Administrative Circular No. 30 (Rev. 2) - Financial Benefits upon taking up appointment and termination of contract. Progressive Retirement Programme The Progressive Retirement Programme (PR...

  17. ISSP Position Stand

    DEFF Research Database (Denmark)

    Ryba, Tatiana; Stambulova, Natalia; Si, Gangyan

    2013-01-01

    but as relational and ␣uid; and (c) focusing on meaning (instead of cause) in cross-cultural and cultural research projects, and cultural praxis work. In the paper, we ␣rst provide an overview of the concepts of cultural competence and ethics of difference. Second, we present a step-by-step approach for developing...... a culturally competent project rooted either within cross-cultural or cultural research. Third, we focus on cultural praxis as a project that blends theory, research, and lived culture of practice. Finally, we summarize main points in nine postulates and provide recommendations for enhancing cultural......The multicultural landscape of contemporary sport sets a challenge to rethink sport and exercise psychology research and practice through a culturally re␣exive lens. This ISSP Position Stand provides a rigorous synthesis and engagement with existing scholarship to outline a roadmap for future work...

  18. Standing Concertation Commmittee

    CERN Multimedia

    HR Department

    2007-01-01

    Ordinary meeting on 2 november 2007 Extraordinary meeting on 12 November 2007 The main items discussed at the meetings of the Standing Concertation Committee on 2 November 2007 and 12 November included: Restaurants Supervisory Committee Report The committee took note of the report by the chairman of the Restaurants Supervisory Committee (RSC), T. Lagrange. In particular, it was recorded that, in Restaurant No. 1, the new kitchen and free flow arrangements had been inaugurated and all works had been commissioned on schedule in October 2007.The contractor, Novae, had taken over maintenance of the new kitchen. Some price increases were to be expected in the coming months due mainly to strong increases in the cost of basic ingredients. A problem with bad smells in the area of Restaurant No. 1 was being taken care of by tuning the ventilation system. The RSC wished to thank the management and staff of Restaurant No. 2 for their cooperation while Restaurant No 1 was ...

  19. Standing Concertation Committee

    CERN Multimedia

    HR Department

    2010-01-01

    Main issues examined at the meeting of 2 October 2009 The October 2009 meeting of the Standing Concertation Committee was entirely devoted to preparation of TREF’s meeting on 21-22 October. The Committee took note of, discussed and agreed on clarifications needed to some of the documents and presentations that the Management intended to submit and/or present to TREF on the following subjects: Equal opportunities The Committee took note of a preliminary report on equal opportunities at CERN drawn up by D. Chromek-Burckhart, the Equal Opportunities Officer, and T. Smith, Chairman of the Equal Opportunities Advisory Panel, containing in particular a proposal for a new process for resolving harassment conflicts. Technical analysis of the CERN Health Insurance Scheme - Actuary’s Report The Committee took note of a presentation by P. Charpentier, Chairman of the CERN Health Insurance Supervisory Board (CHIS Board), on the 2009 actuarial report on the CERN Health Insurance Scheme (CHIS). Th...

  20. Standing Concertation Committee

    CERN Multimedia

    HR Department

    2009-01-01

    The main items discussed at the meetings of the Standing Concertation Committee in the first quarter of 2009 included: Merit Appraisal and Recognition Scheme (MARS) 2009 exercise The committee took note of 2009 MARS ceiling guidelines giving the advancement budget by career path and amounting to approx 1.80% of the basic salary bill. To this will be added 250 steps CERN-wide, financed by savings from implementation of the international indemnity for 2007, 2008 and the first half of 2009. The specific Senior Staff Guidelines, including the proposed number of promotions from Career Path E to F, were also noted. The guidelines with respect to step distribution were also noted: the minima and maxima remain the same as in previous years. Compliance with the guidelines will continue to be monitored closely (more details, including a frequently asked questions section). It was also noted that Financial Awards (awards for extraordinary service and responsibility allowances) may b...

  1. Horizontal gene transfer in chromalveolates

    Directory of Open Access Journals (Sweden)

    Bhattacharya Debashish

    2007-09-01

    Full Text Available Abstract Background Horizontal gene transfer (HGT, the non-genealogical transfer of genetic material between different organisms, is considered a potentially important mechanism of genome evolution in eukaryotes. Using phylogenomic analyses of expressed sequence tag (EST data generated from a clonal cell line of a free living dinoflagellate alga Karenia brevis, we investigated the impact of HGT on genome evolution in unicellular chromalveolate protists. Results We identified 16 proteins that have originated in chromalveolates through ancient HGTs before the divergence of the genera Karenia and Karlodinium and one protein that was derived through a more recent HGT. Detailed analysis of the phylogeny and distribution of identified proteins demonstrates that eight have resulted from independent HGTs in several eukaryotic lineages. Conclusion Recurring intra- and interdomain gene exchange provides an important source of genetic novelty not only in parasitic taxa as previously demonstrated but as we show here, also in free-living protists. Investigating the tempo and mode of evolution of horizontally transferred genes in protists will therefore advance our understanding of mechanisms of adaptation in eukaryotes.

  2. Integration of the Autarkic Hybrid into a motor vehicle and set-up in the system test stand; Integration des Autarken Hybrid in ein KFZ und Aufbau am Systempruefstand

    Energy Technology Data Exchange (ETDEWEB)

    Hoehn, B.R.; Pflaum, H.; Schmidbauer, T.

    1999-07-01

    At the TU of Munich a test vehicle is currently equipped with the drive system ''Autarkic Hybrid''. Apart from the drive unit consisting of the serial combustion engine, a i{sub 2} transmission and the electric engine additional components, such as the hydraulic supply must be integrated in the engine room. The traction battery, components of the control system, the extended electric power supply and the acquisition of measuring data are integrated in the trunk or on the back seats. Several systems which already exist in the vehicle loose their function due to the retrofitting and must be replaced. Additional display and operating elements are available for the driver. The Autarkic Hybrid is not only integrated into a vehicle but also set-up in the system test stand of the FZG. This combination enables a two-way testing and optimisation of the drive system. (orig.) [German] An der TU Muenchen wird gegenwaertig ein Versuchsfahrzeug mit dem Antriebsstrang 'Autarker Hybrid' ausgestattet. Neben der Antriebseinheit bestehend aus dem serienmaessigen Verbrennungsmotor, einem i{sup 2}-Getriebe und einer Elektromaschine muessen zusaetzliche Komponenten, wie beispielsweise die Hydraulikversorgung, im Motorraum untergebracht werden. Die Traktionsbatterie, Komponenten der Regelung, die erweiterte Stromversorgung und eine Messdatenerfassung finden im Bereich der Ladeflaeche bzw. auf der Ruecksitzbank Platz. Verschiedene im Fahrzeug bereits vorhandene Systeme verlieren im Rahmen der Umruestung ihre Funktion, entfallen daher oder muessen ersetzt werden. Dem Fahrer stehen zusaetzliche Anzeige- und Bedienelemente zur Verfuegung. Parallel zum Versuchsfahrzeug erfolgt ein Aufbau des Autarken Hybrid auf dem Systempruefstand der FZG. Im Zusammenspiel mit dem Versuchsfahrzeug wird hierdurch eine zweigleisige Erprobung und Optimierung des Antriebsstrangs moeglich. (orig.)

  3. Relative Soothing Effects of Vertical and Horizontal Rocking.

    Science.gov (United States)

    Pederson, David R.; And Others

    In this study designed to compare the relative pacifying properties of horizontal and vertical rocking, 13 infants (mean age--58 days) were each tested on two subsequent days. The rocking device was a cradle that could be manipulated to produce side-to-side rocking similar to a commercial cradle or up-and-down rocking. In its up-and-down mode, the…

  4. Experimental study of buoyancy driven natural ventilation through horizontal openings

    DEFF Research Database (Denmark)

    Heiselberg, Per; Li, Zhigang

    2007-01-01

    An experimental study of buoyancy driven natural ventilation through single-sided horizontal openings was performed in a full-scale laboratory test rig. Measurements were made for opening ratios L/D range from 0.027 to 4.455, where L and D are the length and the diameter of the opening, respectiv...

  5. Horizontal and vertical resistance strength of infrazygomatic mini-implants.

    Science.gov (United States)

    Wu, J-H; Lu, P-C; Lee, K-T; Du, J-K; Wang, H-C; Chen, C-M

    2011-05-01

    This study assessed the adequacy of anchorage strength of infrazygomatic mini-implants in vertical and horizontal directions. Each brand of infrazygomatic mini-implant tested provided acceptable skeletal anchorage. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Horizontal gene transfer in choanoflagellates.

    Science.gov (United States)

    Tucker, Richard P

    2013-01-01

    Horizontal gene transfer (HGT), also known as lateral gene transfer, results in the rapid acquisition of genes from another organism. HGT has long been known to be a driving force in speciation in prokaryotes, and there is evidence for HGT from symbiotic and infectious bacteria to metazoans, as well as from protists to bacteria. Recently, it has become clear that as many as a 1,000 genes in the genome of the choanoflagellate Monosiga brevicollis may have been acquired by HGT. Interestingly, these genes reportedly come from algae, bacteria, and other choanoflagellate prey. Some of these genes appear to have allowed an ancestral choanoflagellate to exploit nutrient-poor environments and were not passed on to metazoan descendents. However, some of these genes are also found in animal genomes, suggesting that HGT into a common ancestor of choanozoans and animals may have contributed to metazoan evolution. Copyright © 2012 Wiley Periodicals, Inc.

  7. Hue geometry and horizontal connections.

    Science.gov (United States)

    Ben-Shahar, Ohad; Zucker, Steven W

    2004-01-01

    Primate visual systems support an elaborate specialization for processing color information. Concentrating on the hue component, we observe that, contrary to Mondrian-like assumptions, hue varies in a smooth manner for ecologically important natural imagery. To represent these smooth variations, and to support those information processing tasks that utilize hue, a piecewise smooth hue field is postulated. The geometry of hue-patch interactions is developed analogously to orientation-patch interactions in texture. The result is a model for long-range (horizontal) interactions in the color domain, the power of which is demonstrated on a number of examples. Implications for computer image processing, computer vision, visual neurophysiology and psychophysics are discussed.

  8. Explorando nuevos horizontes en NASA

    Science.gov (United States)

    Villanueva, G. L.

    A pesar de la incesante expansión del Universo iniciada con el Big Bang 14 mil millones de años atrás, nuestro Universo se siente cada día más cercano. La inquebrantable vocación de la humanidad por descubrir nuevos horizontes ha permitido el acercamiento de civilizaciones en nuestro planeta y nos ha permitido conocer nuestro lugar en el Universo como nunca antes. En este artículo presento una breve sinopsis de nuestro trabajo que se relaciona con diversas investigaciones con implicaciones astrobiológicas, desde el origen de los ingredientes de la "sopa de la vida", hasta la evolución y composición de la atmósfera de Marte.

  9. Investigation of gravity waves using horizontally resolved radial velocity measurements

    Science.gov (United States)

    Stober, G.; Sommer, S.; Rapp, M.; Latteck, R.

    2013-10-01

    The Middle Atmosphere Alomar Radar System (MAARSY) on the island of Andøya in Northern Norway (69.3° N, 16.0° E) observes polar mesospheric summer echoes (PMSE). These echoes are used as tracers of atmospheric dynamics to investigate the horizontal wind variability at high temporal and spatial resolution. MAARSY has the capability of pulse-to-pulse beam steering allowing for systematic scanning experiments to study the horizontal structure of the backscatterers as well as to measure the radial velocities for each beam direction. Here we present a method to retrieve gravity wave parameters from these horizontally resolved radial wind variations by applying velocity azimuth display and volume velocity processing. Based on the observations a detailed comparison of the two wind analysis techniques is carried out in order to determine the zonal and meridional wind as well as to measure first-order inhomogeneities. Further, we demonstrate the possibility to resolve the horizontal wave properties, e.g., horizontal wavelength, phase velocity and propagation direction. The robustness of the estimated gravity wave parameters is tested by a simple atmospheric model.

  10. Investigation of gravity waves using horizontally resolved radial velocity measurements

    Directory of Open Access Journals (Sweden)

    G. Stober

    2013-10-01

    Full Text Available The Middle Atmosphere Alomar Radar System (MAARSY on the island of Andøya in Northern Norway (69.3° N, 16.0° E observes polar mesospheric summer echoes (PMSE. These echoes are used as tracers of atmospheric dynamics to investigate the horizontal wind variability at high temporal and spatial resolution. MAARSY has the capability of pulse-to-pulse beam steering allowing for systematic scanning experiments to study the horizontal structure of the backscatterers as well as to measure the radial velocities for each beam direction. Here we present a method to retrieve gravity wave parameters from these horizontally resolved radial wind variations by applying velocity azimuth display and volume velocity processing. Based on the observations a detailed comparison of the two wind analysis techniques is carried out in order to determine the zonal and meridional wind as well as to measure first-order inhomogeneities. Further, we demonstrate the possibility to resolve the horizontal wave properties, e.g., horizontal wavelength, phase velocity and propagation direction. The robustness of the estimated gravity wave parameters is tested by a simple atmospheric model.

  11. Maxillary repositioning according to Frankfort horizontal plane during orthognathic surgery.

    Science.gov (United States)

    Ghoreishian, Mehdi; Hasheminia, Dariush; Hashemzehi, Hadi; Khazaei, Saber

    2013-01-01

    There are a lot of disagreements among surgeons over controlling the maxillary position during orthognathic surgery. To investigate maxillary repositioning according to Frankfort horizontal plane in orthognathic surgery. Fourteen patients were selected who were submitted to maxillary or bimaxillary surgery. Maxillary model surgery was performed based on the treatment planning and an intermediate splint was made. The surgical technique in this study was based on maxillary osteotomy according to the findings of the model surgery, in a manner that the osteotomy line was parallel to the Frankfort horizontal plane. Intermediate splint was used for repositioning of the maxilla in the new position and the vertical position of that was determined according to external reference point and fixed on this position. The upper central incisor designed from prediction tracing and post-operative cephalometry on the first tracing. The new position of maxilla was evaluated horizontally and vertically. A paired t-test was used to compare the predicted maxillary position and the actual position. Association between these two groups of variables was evaluated with Pearson correlation. The mean difference between the maxillary planned position and post-operative cephalometric radiography varied between 0.3 mm and 0.9 mm vertically (P value = 0.315) and 0.0 mm and 0.9 mm horizontally (P value = 0.034). The averages of horizontally and vertically observed changes were 0.3 mm and 0.17 mm respectively (P surgery. By eliminating the ramping effect the accuracy of surgery increases.

  12. Standing concertation commmittee

    CERN Multimedia

    HR Department

    2009-01-01

    MEETINGS ON 2 AND 9 DECEMBER 2008 The main items discussed at the meetings of the Standing Concertation Committee on 2 and 9 December 2008 included: Medical Service Report 2007 The Committee took note of the report by Dr. E. Reymond (see http://sc-me.web.cern.ch/sc-me/fr/indexFR.htm) and of a number of points raised during the discussion. It was noted that the number of professional accidents declined in 2007 (361 accidents) in comparison with 2006 (483), as well as their gravity and frequency. The CERN Medical Service carried out a study on cancer prevalence (number of cases) and incidence (new cases per year per 100000 people), between 1993 and 2007, which identified some prostate, breast and colorectal cancers, though less than in the two Host States. Specific preventive actions will be promoted by the CERN CHISboard and the Medical Service in this context as well as in other areas. The committee expressed its thanks to all members of the Medical Service for their work i...

  13. Stand-up physics

    CERN Multimedia

    2009-01-01

    A CMS physicist and amateur stand up comic was named the winner of NESTA FameLab 2009. Tom Whyntie battled it out with nine others young scientists from across the UK to win the contest to find the country’s next top science communicator. Tom Whyntie with his prize money after the NESTA Famelab final.Tom Whyntie, who is currently doing his PhD on the CMS experiment, managed to persuade his supervisor to give him a few days off on 5 June so he could fly back to the UK for the final of NESTA FameLab 2009. In the competition, which has been dubbed ‘the X Factor for scientists’, he had just three minutes to explain a complex scientific idea to a panel of judges made up of high-profile science professionals. During the final, he captivated the audience with his talk about how finding nothing at the LHC, far from being a waste of £5 billion, would actually catalyse the next scientific revolution. It Whyntie’s own words: "If the L...

  14. Standing Concertation Commmittee

    CERN Document Server

    HR Department

    2007-01-01

    Ordinary meeting on 27 February 2007 The main items discussed at the meeting of the Standing Concertation Committee on 27 February 2007 included: Saved Leave Scheme (SLS): It was announced that a Management/Staff Association working group had been set up to discuss the Saved Leave Scheme (SLS): Members: M. Büttner, E. Chiaveri (chair), Ph. Defert, D. Klem, M. Vitasse, J.-M. Saint-Viteux. It was noted that the Staff Association was launching a questionnaire on SLS and distributed to all members of the personnel. Merit Recognition Guidelines : in the context of the new Merit Appraisal and Recognition Scheme (MARS), the committee took note of the CERN-wide 2007 Merit Recognition Guidelines, including the Frequently Asked Questions on HR Department's dedicated website. Information on CERN's medium and long-term plans (MTP-LTP)/Contract renewals/ External mobility The Committee took note of the information provided on CERN's MTP-LTP and of documentation distributed at the meeting by the Staff Associatio...

  15. Standing Concertation Committee

    CERN Multimedia

    HR Department

    2007-01-01

    ORDINARY MEETING ON 27 FEBRUARY 2007 The main items discussed at the meeting of the Standing Concertation Committee on 27 February 2007 included: Saved Leave Scheme (SLS): It was announced that a Management/Staff Association working group had been set up to discuss the Saved Leave Scheme (SLS): Members : M. Büttner, E. Chiaveri (chair), Ph. Defert, D. Klem, M. Vitasse, J.-M. Saint-Viteux. It was noted that the Staff Association was launching a questionnaire on SLS and distributed to all members of the personnel. Merit Recognition Guidelines: In the context of the new Merit Appraisal and Recognition Scheme (MARS), the committee took note of the CERN-wide 2007 Merit Recognition Guidelines, including the Frequently Asked Questions on HR Department's dedicated website. Information on CERN's medium and long-term plans (MTP-LTP)/Contract renewals/ External mobility The Committee took note of the information provided on CERN's MTP-LTP and of documentation distributed at the meeting by the Staff ...

  16. Standing Concertation Committee

    CERN Multimedia

    2007-01-01

    Ordinary meeting on 30 January 2007 The main items discussed at the meeting of the Standing Concertation Committee on 30 January 2007 included: Administrative Circular No. 26: with the introduction of the merit recognition system in the framework of the 5-yearly review of CERN employment conditions, Administrative Circular No. 26 has been revised. The committee took note of the revised document which is being finalized for submission to the Director-General for approval in the near future. Technical analysis of CERN Health Insurance Scheme: the Committee was informed that a group has been set up by the Director-General to analyse the financial situation of the CERN Health Insurance Scheme in the short and long term, and to propose measures to ensure that the Scheme remains in financial balance, with adequate cover, over the medium term. The group's terms of reference and membership were communicated. Voluntary programmes It was announced that the programmes: 'part-time work as a pre-retirement measure...

  17. Standing Concertation Committee

    CERN Multimedia

    2007-01-01

    ORDINARY MEETING ON 30 JANUARY 2007 The main items discussed at the meeting of the Standing Concertation Committee on 30 January 2007 included: Administrative Circular No. 26: with the introduction of the merit recognition system in the framework of the 5-yearly review of CERN employment conditions, Administrative Circular No. 26 has been revised. The Committee took note of the revised document which is being finalized for submission to the Director-General for approval in the near future. Technical analysis of CERN Health Insurance Scheme: the Committee was informed that a group has been set up by the Director-General to analyse the financial situation of the CERN Health Insurance Scheme in the short and long term, and to propose measures to ensure that the Scheme remains in financial balance, with adequate cover, over the medium term. The group's terms of reference and membership were communicated. Voluntary programmes It was announced that the programmes: 'part-time work as a pre-retirement mea...

  18. Habitat diversity in uneven-aged northern hardwood stands: a case study

    Science.gov (United States)

    Laura S. Kenefic; Ralph D. Nyland

    2000-01-01

    Habitat characteristics were quantified in an empirically balanced uneven-aged northern hardwood stand in central New York. Canopy structure, wildlife trees, downed woody material, low cover, and richness and abundance of understory vegetation were assessed. High vertical structural diversity and low horizontal patchiness were associated with the single-tree selection...

  19. Dynamics of Connecticut hemlock stands

    Science.gov (United States)

    Jeffrey S. Ward; David M. Smith

    2000-01-01

    The stand dynamics and production of two one-acre plots of eastern hemlock (Tsuga canadensis L) in Connecticut have been followed for more than six decades. Data were recorded for all individual trees. One plot (Saltonstall) was established in 1924 after the removal of a hardwood overstory. This stand had a nearly pure, almost fully closed understory...

  20. Performance of a Horizontal Triple Cylinder Type Pulping Machine

    Directory of Open Access Journals (Sweden)

    Sukrisno Widyotomo

    2011-05-01

    Full Text Available Pulping is one important step in wet coffee processing method. Pulping process usually uses a machine which constructed by wood or metal materials. A horizontal single cylinder type of fresh coffee cherries pulping machine is the most popular machine in coffee processing. One of the weaknesses of a horizontal single cylinder type of fresh coffee cherries pulping machine is higher in broken beans. Broken bean is one of mayor aspects in defect system that contribute to low quality. Indonesian Coffee and Cocoa Research Institute has designed and tested a horizontal double cylinder type of fresh coffee cherries pulping machine which resulted in 12.6—21.4% of broken beans. To reduce percentage of broken beans, Indonesian Coffee and Cocoa Research Institute has developed and tested a horizontal triple cylinder type of fresh coffee cherries pulping machine. Material tested was fresh mature Robusta coffee cherries, 60—65% (wet basis moisture content; has classified on 3 levels i.e. unsorted, small and medium, and clean from metal and foreign materials. The result showed that the machine produced 6,340 kg/h in optimal capacity for operational conditions, 1400 rpm rotor rotation speed for unsorted coffee cherries with composition 55.5% whole parchment coffee, 3.66% broken beans, and 1% beans in wet skin.Key words : coffee, pulp, pulper, cylinder, quality.

  1. Horizontal Cells of the Primate Retina: Cone Specificity Without Spectral Opponency

    Science.gov (United States)

    Dacey, Dennis M.; Lee, Barry B.; Stafford, Donna K.; Pokorny, Joel; Smith, Vivianne C.

    1996-02-01

    The chromatic dimensions of human color vision have a neural basis in the retina. Ganglion cells, the output neurons of the retina, exhibit spectral opponency; they are excited by some wavelengths and inhibited by others. The hypothesis that the opponent circuitry emerges from selective connections between horizontal cell interneurons and cone photoreceptors sensitive to long, middle, and short wavelengths (L-, M-, and S-cones) was tested by physiologically and anatomically characterizing cone connections of horizontal cell mosaics in macaque monkeys. H1 horizontal cells received input only from L- and M-cones, whereas H2 horizontal cells received a strong input from S-cones and a weaker input from L- and M-cones. All cone inputs were the same sign, and both horizontal cell types lacked opponency. Despite cone type selectivity, the horizontal cell cannot be the locus of an opponent transformation in primates, including humans.

  2. Gas reservoir evaluation for underbalanced horizontal drilling

    National Research Council Canada - National Science Library

    Li Gao; Meng Ying-Feng; Wei Na; Xu Zhao-Yang; Li Hong-Tao; Xiao Gui-Lin; Zhang Yu-Rui

    2014-01-01

    .... Based on drilling operation parameters, well structure and monitored parameters, the wellbore pressure and the gas reservoir permeability could be predicted theoretically for underbalanced horizontal drilling...

  3. Thrust stand for high-power electric propulsion devices

    Science.gov (United States)

    Haag, T. W.

    1991-01-01

    This paper describes a new high-power thrust stand developed for use with high-power (up to 250 kW) magnetoplasmadynamic (MPD) thrusters, which is installed in a high-vacuum MPD facility at Lewis Research Center. The design of the stand is based on inverted pendulum configuration, with the result of large displacements and high resolution. Calibration results showed that thrust measurements were linear and repeatable to within a fraction of 1 percent. The thrust stand was used for testing water-cooled MPD thrusters at power levels up to 125 kW. The thruster, however, is quite well suited for testing other types of electric propulsion devices.

  4. How a GNSS Receiver Is Held May Affect Static Horizontal Position Accuracy.

    Science.gov (United States)

    Weaver, Steven A; Ucar, Zennure; Bettinger, Pete; Merry, Krista

    2015-01-01

    The static horizontal position accuracy of a mapping-grade GNSS receiver was tested in two forest types over two seasons, and subsequently was tested in one forest type against open sky conditions in the winter season. The main objective was to determine whether the holding position during data collection would result in significantly different static horizontal position accuracy. Additionally, we wanted to determine whether the time of year (season), forest type, or environmental variables had an influence on accuracy. In general, the F4Devices Flint GNSS receiver was found to have mean static horizontal position accuracy levels within the ranges typically expected for this general type of receiver (3 to 5 m) when differential correction was not employed. When used under forest cover, in some cases the GNSS receiver provided a higher level of static horizontal position accuracy when held vertically, as opposed to held at an angle or horizontally (the more natural positions), perhaps due to the orientation of the antenna within the receiver, or in part due to multipath or the inability to use certain satellite signals. Therefore, due to the fact that numerous variables may affect static horizontal position accuracy, we only conclude that there is weak to moderate evidence that the results of holding position are significant. Statistical test results also suggest that the season of data collection had no significant effect on static horizontal position accuracy, and results suggest that atmospheric variables had weak correlation with horizontal position accuracy. Forest type was found to have a significant effect on static horizontal position accuracy in one aspect of one test, yet otherwise there was little evidence that forest type affected horizontal position accuracy. Since the holding position was found in some cases to be significant with regard to the static horizontal position accuracy of positions collected in forests, it may be beneficial to have an

  5. Horizontal Saccadic Eye Movements Enhance the Retrieval of Landmark Shape and Location Information

    Science.gov (United States)

    Brunye, Tad T.; Mahoney, Caroline R.; Augustyn, Jason S.; Taylor, Holly A.

    2009-01-01

    Recent work has demonstrated that horizontal saccadic eye movements enhance verbal episodic memory retrieval, particularly in strongly right-handed individuals. The present experiments test three primary assumptions derived from this research. First, horizontal eye movements should facilitate episodic memory for both verbal and non-verbal…

  6. Análise da associação entre a dinamometria isocinética da articulação do joelho e o salto horizontal unipodal, hop test, em atletas de voleibol Análisis de la asociación entre la dinamometria isocinética de la articulación de la rodilla y el salto horizontal unipodal, hop test, en los atletas de voleibol Analysis on the association between isokinetic dynamometry of the knee's articulation and one-leg horizontal jump, hop test, in volleyball athletes

    Directory of Open Access Journals (Sweden)

    Rogério Leão D'Alessandro

    2005-10-01

    Full Text Available INTRODUÇÃO: O dinamômetro isocinético tem sido largamente utilizado na avaliação da performance muscular. Devido a seu alto custo, a sua utilização torna-se inviável na prática clínica. O hop test é um teste para avaliação da força e da confiança nos membros inferiores (MMII que pode ser utilizado na clínica com pequeno gasto de tempo e mínima demanda financeira. O objetivo deste estudo foi verificar se existe associação entre o hop test e dados da função muscular fornecidos pela avaliação do joelho no dinamômetro isocinético em atletas profissionais. MATERIAIS E MÉTODOS: Trinta atletas de voleibol (oito mulheres e 22 homens foram avaliados no dinamômetro isocinético nas velocidades de 60º/s e 300º/s e no hop test a distância. RESULTADOS: Foi observada somente uma correlação baixa entre déficit de pico de torque (r = 0,441 e de trabalho (r = 0,610 a 60º/s com o déficit da distância saltada entre MMII. Foi observada baixa associação entre a performance muscular e a distância saltada no hop test exceto no membro inferior direito de mulheres. CONCLUSÃO: Este estudo mostrou que o hop test não pode ser usado para substituir a dinamometria isocinética na avaliação da função muscular.INTRODUCCIÓN: El dinamómetro isocinético ha sido largamente utilizado en la evaluación de la performance muscular. Debido a su alto costo, su utilización es inviable en la práctica clínica. El hop test es un test para la evaluación de la fuerza y de la confianza de los miembros inferiores (MMII que puede ser utilizado en la clínica con pequeño gasto de tiempo y mínima demanda financeira. El objetivo de este estudio fué verificar se existe asociación entre el hop test y los datos de la función muscular obtenidos por la evaluación de la rodilla en dinamómetro isocinético en atletas profesionales. MATERIALES Y MÉTODOS: Treinta atletas de voleibol (8 mujeres y 22 hombres fueron evaluados en dinamómetro isocin

  7. A note on the relationship between the quadratic mean stand diameter and harmonic mean basal area under size-biased distribution theory

    Science.gov (United States)

    Jeffrey H. Gove

    2003-01-01

    This note seeks to extend the utility of size-biased distribution theory as applied to forestry through two relationships regarding the quadratic mean stand diameter. First, the quadratic mean stand diameter's relationship to the harmonic mean basal area for horizontal point sampling, which has been known algebraically from early on, is proved under size-biased...

  8. Horizontal vortex single chamber hydroturbine

    Directory of Open Access Journals (Sweden)

    Sergio Antonio Zarate-Orrego

    2016-01-01

    Full Text Available Se evaluó una máquina con alta resistencia de forma para extraer energía de una quebrada, río o corriente marina, y generar electricidad. Sin instrumentos adecuados, la investigación fue cualitativa. Se supuso que si aun así funcionaba, su comportamiento podía mejorar suavizándose la forma. El aparato tiene una tobera semi-convergente de paredes planas, una cámara de vórtice cilíndrica y un rodete. Capta agua por su sección mayor y la descarga tangencialmente por su sección menor en la cámara de vórtice; ésta tiene un orificio en una de sus paredes laterales. Así forma un vórtice horizontal que hace girar un rodete cuyo eje acciona un generador eléctrico. El trabajo experimental realizado mostró que sí es posible producir energía eléctrica con este dispositivo pese a las condiciones adversas en que se ensayó.

  9. Injection chamber test stands for optical testing of GDI injection systems in practically relevant engine conditions; Einspritzkammerpruefstaende fuer die optische Untersuchung von BDE-Einspritzduesen unter motorisch relevanten Bedingungen

    Energy Technology Data Exchange (ETDEWEB)

    Ipp, W.; Lindner, R.; Goldluecke, J.; Schmitz, I.; Leipertz, A. [Erlangen Univ. (Germany). Lehrstuhl fuer Technische Thermodynamik; Lutz, M. [Energie und Systemtechnik, ESYTEC GmbH, Erlangen (Germany)

    2005-07-01

    In GDI engines, the injection system has a significant effect on mixture formation, combustion and pollutant emissions. Therefore it is of basic interest to analyze the injection process at engine relevant conditions, for which contactless optical measurement techniques are particularly suitable. To investigate the specific behavior of the injection system it is required to separate the fuel propagation and evaporation processes from the influence of air motion and wall-interaction as it occurs inside the engine. For this purpose pressure vessels with optical accesses are used which are able to work at engine relevant conditions, regarding pressure as well as temperature. Beside this, for planning of an optical injection test bench, special demands have to be considered like the optimal and multifunctional use of optical measurement techniques, size, handling and safety, the utilization of existing resources as well as internal company regulations of the customer and last but not least, the costs. Considering these aspects the Department for Engineering Thermodynamics (LTT) of the University of Erlangen and the company ESYTEC Energie- und Systemtechnik GmbH have designed and constructed several optical test benches, some of them also for GDI systems. In this contribution the requirements for the optical investigation of GDI injection systems are discussed and an example of an already working test rig is shown. (orig.)

  10. Horizontal cooperation in logistics : Opportunities and impediments

    NARCIS (Netherlands)

    Cruijssen, Frans; Cools, Martine; Dullaert, Wout

    This paper presents the results of a large-scale survey on the potential benefits of and impediments for horizontal cooperation in Flanders. The main findings are that in general Logistics Service Providers strongly believe in the potential benefits of horizontal cooperation to increase their

  11. Rectifying Horizontal Inequalities: Lessons from African Conflict ...

    African Journals Online (AJOL)

    One of the most prevalent and underrepresented root causes of conflict in Africa and worldwide is that of horizontal inequalities. In that light, the goal of this paper is to provide practical solutions for the long-term resolution of conflict by addressing one of its root causes, that of horizontal inequalities. Reference will be made ...

  12. Rectifying Horizontal Inequalities: Lessons from African Conflict

    African Journals Online (AJOL)

    and horizontal (between groups) inequalities. A number of scholars have addressed the question of inequalities. Frances Stewart, for example, deals with the problem of horizontal inequalities in a number of papers.2 Stewart. (2002:3) argues that 'unequal access to political/economic/social resources. 1 The social contract ...

  13. Do infants have the horizontal bias?

    NARCIS (Netherlands)

    van Renswoude, D.R.; Johnson, S.P.; Raijmakers, M.E.J.; Visser, I.

    2016-01-01

    A robust set of studies show that adults make more horizontal than vertical and oblique saccades, while scanning real-world scenes. In this paper we study the horizontal bias in infants. The directions of eye movements were calculated for 41 infants (M = 8.40 months, SD = 3.74, range = 3.48–15.47)

  14. The Process of Horizontal Differentiation: Two Models.

    Science.gov (United States)

    Daft, Richard L.; Bradshaw, Patricia J.

    1980-01-01

    Explores the process of horizontal differentiation by examining events leading to the establishment of 30 new departments in five universities. Two types of horizontal differentiation processes--administrative and academic--were observed and each was associated with different organizational conditions. (Author/IRT)

  15. Horizontal gene transfer in human pathogens.

    Science.gov (United States)

    Juhas, Mario

    2015-02-01

    Horizontal gene transfer has a tremendous impact on the genome plasticity, adaptation and evolution of bacteria. Horizontally transferred mobile genetic elements are involved in the dissemination of antibiotic resistance and virulence genes, thus contributing to the emergence of novel "superbugs". This review provides update on various mechanisms of horizontal gene transfer and examines how horizontal gene transfer contributes to the evolution of pathogenic bacteria. Special focus is paid to the role horizontal gene transfer plays in pathogenicity of the emerging human pathogens: hypervirulent Clostridium difficile and Escherichia coli (including the most recent haemolytic uraemic syndrome outbreak strain) and methicillin-resistant Staphylococcus aureus (MRSA), which have been associated with largest outbreaks of infection recently.

  16. Pure shear horizontal SAW biosensor on langasite.

    Science.gov (United States)

    Berkenpas, Eric; Bitla, Shivashanker; Millard, Paul; da Cunha, Mauricio Pereira

    2004-11-01

    The undetected introduction of pathogens into food or water supplies can produce grave consequences in terms of economic loss and human suffering. Sensitive and selective sensors capable of quickly detecting microbial pathogens are urgently needed to limit the effects of bioterrorist incidents, accidents, or pollution. Shear horizontal surface acoustic wave (SH SAW) devices provide an attractive platform for the design of microbial biosensors that function in liquid media, where Rayleigh-type modes are rapidly attenuated. This paper reports on an exploratory SH SAW delay line designed and fabricated on langasite, La3Ga5SiO14 (LGS), along the novel Euler propagation direction (0 degrees, 22 degrees, 90 degrees). A liquid chamber was fabricated and attached to the top surface, and the device was submitted to liquid and biochemical tests. Moderate (6 dB) additional attenuation of the transmission coefficient, /S21/, was consistently observed when the SH SAW delay line was assembled in the test fixture and submitted to the liquid tests, indicating that LGS is an attractive candidate for liquid sensing. Sensor selectivity can be achieved by integrating the LGS SH SAW delay line with a biochemical recognition layer. A test setup was implemented for the characterization of LGS SH SAW-based biosensors. The delay line response to biomolecule binding was shown by detection of sequential binding of proteins to the SH SAW device delay path. The biotinylated sensor was exposed sequentially to biotin-binding deglycosylated avidin, biotin-modified rabbit IgG, and goat anti-rabbit IgG antibody. As each protein was bound to the sensing surface, marked changes in the delay-line phase were recorded. The reported results demonstrate the capability of these devices to act as biochemical detectors in aqueous solutions, and this work represents the first effort using the novel material LGS in SAW-based biosensor technology.

  17. SSC Test Operations Contract Overview

    Science.gov (United States)

    Kleim, Kerry D.

    2010-01-01

    This slide presentation reviews the Test Operations Contract at the Stennis Space Center (SSC). There are views of the test stands layouts, and closer views of the test stands. There are descriptions of the test stand capabilities, some of the other test complexes, the Cryogenic propellant storage facility, the High Pressure Industrial Water (HPIW) facility, and Fluid Component Processing Facility (FCPF).

  18. The one-leg standing radiograph: An improved technique to evaluate the severity of knee osteoarthritis.

    Science.gov (United States)

    Pinsornsak, P; Naratrikun, K; Kanitnate, S; Sangkomkamhang, T

    2016-09-01

    The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis was evaluated using the joint space width and Kellgren-Lawrence (KL) radiographic classification. The t-test was used for statistical analysis. The mean medial joint space width found in the one-leg and in the both-legs standing view were measured at 1.8 mm and 2.4 mm, respectively (p leg standing views, respectively. No changes for KL IV osteoarthritis diagnoses have been found between both- and one-leg standing views. One-leg standing radiographs better represent joint space width than both-legs standing radiographs. 32% of both-legs standing radiographs have changed the KL grading to a more severe grade than that in the one-leg standing radiographs.Cite this article: P. Pinsornsak, K. Naratrikun, S. Kanitnate, T. Sangkomkamhang. The one-leg standing radiograph: An improved technique to evaluate the severity of knee osteoarthritis. Bone Joint Res 2016;5:436-441. DOI: 10.1302/2046-3758.59.BJR-2016-0049.R1. © 2016 Pinsornsak et al.

  19. Horizontal mantle flow controls subduction dynamics.

    Science.gov (United States)

    Ficini, E; Dal Zilio, L; Doglioni, C; Gerya, T V

    2017-08-08

    It is generally accepted that subduction is driven by downgoing-plate negative buoyancy. Yet plate age -the main control on buoyancy- exhibits little correlation with most of the present-day subduction velocities and slab dips. "West"-directed subduction zones are on average steeper (~65°) than "East"-directed (~27°). Also, a "westerly"-directed net rotation of the lithosphere relative to the mantle has been detected in the hotspot reference frame. Thus, the existence of an "easterly"-directed horizontal mantle wind could explain this subduction asymmetry, favouring steepening or lifting of slab dip angles. Here we test this hypothesis using high-resolution two-dimensional numerical thermomechanical models of oceanic plate subduction interacting with a mantle flow. Results show that when subduction polarity is opposite to that of the mantle flow, the descending slab dips subvertically and the hinge retreats, thus leading to the development of a back-arc basin. In contrast, concordance between mantle flow and subduction polarity results in shallow dipping subduction, hinge advance and pronounced topography of the overriding plate, regardless of their age-dependent negative buoyancy. Our results are consistent with seismicity data and tomographic images of subduction zones. Thus, our models may explain why subduction asymmetry is a common feature of convergent margins on Earth.

  20. Yaw dynamics of horizontal axis wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Hansen, A.C. (Utah Univ., Salt Lake City, UT (United States))

    1992-05-01

    Designers of a horizontal axis wind turbine yaw mechanism are faced with a difficult decision. They know that if they elect to use a yaw- controlled rotor then the system will suffer increased initial cost and increased inherent maintenance and reliability problems. On the other hand, if they elect to allow the rotor to freely yaw they known they will have to account for unknown and random, though bounded, yaw rates. They will have a higher-risk design to trade-off against the potential for cost savings and reliability improvement. The risk of a yaw-free system could be minimized if methods were available for analyzing and understanding yaw behavior. The complexity of yaw behavior has, until recently, discouraged engineers from developing a complete yaw analysis method. The objectives of this work are to (1) provide a fundamental understanding of free-yaw mechanics and the design concepts most effective at eliminating yaw problems, and (2) provide tested design tools and guidelines for use by free-yaw wind systems manufacturers. The emphasis is on developing practical and sufficiently accurate design methods.

  1. Take a Stand!

    DEFF Research Database (Denmark)

    Danquah, I. H.; Kloster, S.; Holtermann, A.

    2017-01-01

    Background: Prolonged sitting time has been associated with adverse health outcomes. Interventions at work may contribute to reduced sitting. The objective was to test if a multicomponent work-based intervention can reduce sitting time and the number of prolonged sitting periods (> 30 min...... workers in total) were cluster randomized for intervention or control. The intervention included the appointment of local ambassadors, management support, environmental changes, a lecture and a workshop. Sitting time was measured using an ActiGraph GT3X+ fixed on the thigh. Data were processed using Acti4...... workday in the intervention group compared with the control group. At 1 month, the number of prolonged sitting periods was lower (-0.79/8-h workday, P intervention compared with the control group. After 3 months...

  2. Recompletion by horizontal drilling pays off

    Energy Technology Data Exchange (ETDEWEB)

    Holifield, R.H.; Rehm, B.

    1989-03-01

    More than 20 wells have been recompleted in the Giddings field by drilling a new, horizontal interval from existing 5 1/2-in. cased wells for distances of 300 to 1,250 ft. Recompleting existing wells is much cheaper than drilling a new well. Plus, the new completions, overall, produce better. The horizontal wells are routinely profitable now, and pay out occurs in 3 to 24 months. During this program, the techniques for slim-hole- medium-radius, horizontal drilling in Giddings have been mastered and costs have dropped 75%. It is believed that this program may be the first (or among the first) continuing horizontal project drilled out of cased wells with repeatable profitability as opposed to projected viability.

  3. Productivity and injectivity of horizontal wells

    Energy Technology Data Exchange (ETDEWEB)

    Aziz, Khalid

    2000-03-06

    One of the key issues addressed was pressure drop in long horizontal wells and its influence on well performance. Very little information is available in the literature on flow in pipes with influx through pipe walls. Virtually all of this work has been in small diameter pipes and with single-phase flow. In order to address this problem new experimental data on flow in horizontal and near horizontal wells have been obtained. Experiments were conducted at an industrial facility on typical 6 1/8 ID, 100 feet long horizontal well model. The new data along with available information in the literature have been used to develop new correlations and mechanistic models. Thus it is now possible to predict, within reasonable accuracy, the effect of influx through the well on pressure drop in the well.

  4. Horizontal Compilations of Nuclear Data III

    Science.gov (United States)

    Soroko, Z. N.; Sukhoruchkin, S. I.; Sukhoruchkin, D. S.

    2001-11-01

    Compilations of resonance parameters for all nuclei (horizontal-type compilations) derived from study of reactions with neutrons and charge particles are described. Systematic trends in experimental data due to the differences in energy scales of spectrometers were found after comparison of data for many nuclei. The combination of data from horizontal-type compilations with data from the well-known file ENSDF expands the usefulness of these data files.

  5. Horizontal Brand Extension and Customer perception

    OpenAIRE

    Khan, Khalid; Janthimapornkij, Rattanawilai

    2011-01-01

    Company use different method for extended their business to different market and to different segment. They use different method; brand extension is one of popular strategy for extension of business. Brand extension does not become successful for every brand, it is very risky. The purpose of this thesis is to study horizontal brand extension and customer perception. We will discuss horizontal brand extension and its two main types franchise brand extension and line extension. Brand extension ...

  6. Residual Liquefaction under Standing Waves

    DEFF Research Database (Denmark)

    Kirca, V.S. Ozgur; Sumer, B. Mutlu; Fredsøe, Jørgen

    2012-01-01

    This paper summarizes the results of an experimental study which deals with the residual liquefaction of seabed under standing waves. It is shown that the seabed liquefaction under standing waves, although qualitatively similar, exhibits features different from that caused by progressive waves....... The experimental results show that the buildup of pore-water pressure and the resulting liquefaction first starts at the nodal section and spreads towards the antinodal section. The number of waves to cause liquefaction at the nodal section appears to be equal to that experienced in progressive waves for the same...... wave height. Recommendations are made as to how to assess liquefaction potential in standing waves. Copyright © 2012 by the International Society of Offshore and Polar Engineers (ISOPE)....

  7. Horizontal drilling pilot in a shallow heavy oil reservoir in the Suplac Field in Northwestern Romania

    Energy Technology Data Exchange (ETDEWEB)

    Lavelle, J.; Yaghoobi, A. [OMV Petrom S.A. (Romania)

    2011-07-01

    The Suplac field situated in north-western Romania is a shallow and heavy oil deposit lying at depths of between 40 and 200 meters. The deposit has been exploited since 1964 using different techniques but some areas of the reservoir located beneath villages and steep hills were never reached. The aim of this paper is to describe a project using horizontal alternating steam drive (HASD) to harvest oil from these areas by turning from vertical to horizontal. A pilot test was conducted over 4 months in 2010 with 3 parallel horizontal wells. The rig equipment, the well path designs and the directional difficulties are discussed herein. Results showed that horizontals could be drilled using a vertical mast rig and all the expectations were met. The success of this pilot project was highlighted herein and the company is now planning on continuing with a horizontal development program; however wellbore clean out is a remaining challenge.

  8. User's Guide to the Stand Prognosis Model

    Science.gov (United States)

    William R. Wykoff; Nicholas L. Crookston; Albert R. Stage

    1982-01-01

    The Stand Prognosis Model is a computer program that projects the development of forest stands in the Northern Rocky Mountains. Thinning options allow for simulation of a variety of management strategies. Input consists of a stand inventory, including sample tree records, and a set of option selection instructions. Output includes data normally found in stand, stock,...

  9. Stocking, growth, and yield of oak stands

    Science.gov (United States)

    Samuel F. Gingrich

    1971-01-01

    An appraisal of stocking in even-aged upland oak stands is a prerequisite for determining the cultural needs of a given stand. Most oak stands have sufficient stocking to utilize the site, but are deficient in high-quality trees. Thinning such stands offers a good opportunity to upgrade the relative quality of the growing stock and enhance the growth and yield...

  10. Do infants have the horizontal bias?

    Science.gov (United States)

    Van Renswoude, D R; Johnson, S P; Raijmakers, M E J; Visser, I

    2016-08-01

    A robust set of studies show that adults make more horizontal than vertical and oblique saccades, while scanning real-world scenes. In this paper we study the horizontal bias in infants. The directions of eye movements were calculated for 41 infants (M=8.40 months, SD=3.74, range=3.48-15.47) and 47 adults (M=21.74 years, SD=4.54, range=17.89-39.84) while viewing 28 real-world scenes. Saccade directions were binned to study the proportion of saccades in the horizontal, vertical and oblique directions. In addition, saccade directions were also modeled using a mixture of Von Mises distributions, to account for the relatively large amount of variance in infants data. Horizontal bias was replicated in adults and also found in infants, using both the binning and Von Mises approach. Moreover, a developmental pattern was observed in which older infants are more precise in targeting their saccades than younger infants. That infants have a horizontal bias is important in understanding infants' eye movements. Future studies should account for the horizontal bias in their designs and analyses. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Students dance longitudinal standing waves

    Science.gov (United States)

    Ruiz, Michael J.

    2017-05-01

    A demonstration is presented that involves students dancing longitudinal standing waves. The resulting kinaesthetic experience and visualization both contribute towards an understanding of the natural modes of vibrations in open and closed pipes. A video of this fun classroom activity is provided (http://mjtruiz.com/ped/dance/).

  12. Silvicultural treatments in immature stands

    Science.gov (United States)

    Richard C. Schlesinger

    1989-01-01

    Silvicultural treatments for immature central hardwood stands include precommercial and commercial thinnings, lateral branch pruning, fertilization, cull tree deadening, and vine removal. The specifics of these treatments are discussed elsewhere in these Notes. This Note discusses some basic concepts in the selection and application of silvicultural treatments for...

  13. Burnout : de stand van zaken

    NARCIS (Netherlands)

    Taris, T.; Houtman, I.L.D.; Schaufeli, W.

    2013-01-01

    Dit artikel geeft een overzicht van de stand van zaken in het onderzoek naar burnout. Burnout is een syndroom van extreme vermoeidheid (uitputting), afstand nemen van het werk (distantie) en weinig vertrouwen in het eigen kunnen (verminderde competentie), waarbij de oorzaken voor deze aspecten

  14. Prognosis model for stand development

    Science.gov (United States)

    Albert R. Stage

    1973-01-01

    Describes a set of computer programs for developing prognoses of the development of existing stand under alternative regimes of management. Calibration techniques, modeling procedures, and a procedure for including stochastic variation are described. Implementation of the system for lodgepole pine, including assessment of losses attributed to an infestation of mountain...

  15. Crown management and stand density

    Science.gov (United States)

    Thomas J. Dean; V. Clark Baldwin

    1996-01-01

    Determination of optimal stand-density continues to be a difficult problem. A trial cannot be established on every combination of soils, topography, and climate possible across the range of a widely distributed species such as loblolly pine, and continual advancements in nutrition and vegetation management, breeding, and utilization make established trials obsolete....

  16. Natural convection heat transfer within horizontal spent nuclear fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Canaan, R.E.

    1995-12-01

    Natural convection heat transfer is experimentally investigated in an enclosed horizontal rod bundle, which characterizes a spent nuclear fuel assembly during dry storage and/or transport conditions. The basic test section consists of a square array of sixty-four stainless steel tubular heaters enclosed within a water-cooled rectangular copper heat exchanger. The heaters are supplied with a uniform power generation per unit length while the surrounding enclosure is maintained at a uniform temperature. The test section resides within a vacuum/pressure chamber in order to subject the assembly to a range of pressure statepoints and various backfill gases. The objective of this experimental study is to obtain convection correlations which can be used in order to easily incorporate convective effects into analytical models of horizontal spent fuel systems, and also to investigate the physical nature of natural convection in enclosed horizontal rod bundles in general. The resulting data consist of: (1) measured temperatures within the assembly as a function of power, pressure, and backfill gas; (2) the relative radiative contribution for the range of observed temperatures; (3) correlations of convective Nusselt number and Rayleigh number for the rod bundle as a whole; and (4) correlations of convective Nusselt number as a function of Rayleigh number for individual rods within the array.

  17. Analysis of Human Standing Balance by Largest Lyapunov Exponent

    Directory of Open Access Journals (Sweden)

    Kun Liu

    2015-01-01

    Full Text Available The purpose of this research is to analyse the relationship between nonlinear dynamic character and individuals’ standing balance by the largest Lyapunov exponent, which is regarded as a metric for assessing standing balance. According to previous study, the largest Lyapunov exponent from centre of pressure time series could not well quantify the human balance ability. In this research, two improvements were made. Firstly, an external stimulus was applied to feet in the form of continuous horizontal sinusoidal motion by a moving platform. Secondly, a multiaccelerometer subsystem was adopted. Twenty healthy volunteers participated in this experiment. A new metric, coordinated largest Lyapunov exponent was proposed, which reflected the relationship of body segments by integrating multidimensional largest Lyapunov exponent values. By using this metric in actual standing performance under sinusoidal stimulus, an obvious relationship between the new metric and the actual balance ability was found in the majority of the subjects. These results show that the sinusoidal stimulus can make human balance characteristics more obvious, which is beneficial to assess balance, and balance is determined by the ability of coordinating all body segments.

  18. Application of posterior pelvic tilt taping for the treatment of chronic low back pain with sacroiliac joint dysfunction and increased sacral horizontal angle.

    Science.gov (United States)

    Lee, Jung-hoon; Yoo, Won-gyu

    2012-11-01

    Kinesio Taping (KT) is a therapeutic method used by physical therapists and athletic trainers in combination with other treatment techniques for various musculoskeletal and neuromuscular problems. However, no research has evaluated the effect of KT in patients with low back pain (LBP). The purpose of this case was to describe the application of posterior pelvic tilt taping (PPTT) with Kinesio tape as a treatment for chronic LBP and to reduce the anterior pelvic tilt angle. Case report. The patien was a 20-year-old female amateur swimmer with a Cobb's angle (L1-S1) of 68°, a sacral horizontal angle of 45°, and pain in both medial buttock areas and sacroiliac joints. We performed PPTT with Kinesio tape for 2 weeks (six times per week for an average of 9 h each time). The patient’s radiographs showed that the Cobb's angle (L1-S1) had decreased from 68° to 47° and that the sacral horizontal angle had decreased from 45° to 31°. Reductions in hypomobility or motion asymmetry, as assessed by the motion palpation test, and in pain, as measured by the pain-provocation tests, were observed. On palpation for both medial buttock areas in the prone position, the patient felt no pain. The patient experienced no pain or stiffness in the low back area while performing forward flexion in the standing position with knees fully extended when washing dishes in the sink. The case study demonstrated that PPTT intervention favourably affected the pelvic inclination and sacral horizontal angle, leading to beneficial effects on sacroiliac joint dysfunction (SIJD) and medial buttock pain. Additional research on the clinical effects of this taping procedure requires greater numbers of athletes with SIJD or LBP who have inappropriate anterior pelvic tilt angles and hyperlordosis.

  19. Horizontal alveolar bone loss: A periodontal orphan

    Science.gov (United States)

    Jayakumar, A.; Rohini, S.; Naveen, A.; Haritha, A.; Reddy, Krishnanjeneya

    2010-01-01

    Background: Attempts to successfully regenerate lost alveolar bone have always been a clinician’s dream. Angular defects, at least, have a fairer chance, but the same cannot be said about horizontal bone loss. The purpose of the present study was to evaluate the prevalence of horizontal alveolar bone loss and vertical bone defects in periodontal patients; and later, to correlate it with the treatment modalities available in the literature for horizontal and vertical bone defects. Materials and Methods: The study was conducted in two parts. Part I was the radiographic evaluation of 150 orthopantomographs (OPGs) (of patients diagnosed with chronic periodontitis and seeking periodontal care), which were digitized and read using the AutoCAD 2006 software. All the periodontitis-affected teeth were categorized as teeth with vertical defects (if the defect angle was ≤45° and defect depth was ≥3 mm) or as having horizontal bone loss. Part II of the study comprised search of the literature on treatment modalities for horizontal and vertical bone loss in four selected periodontal journals. Results: Out of the 150 OPGs studied, 54 (36%) OPGs showed one or more vertical defects. Totally, 3,371 teeth were studied, out of which horizontal bone loss was found in 3,107 (92.2%) teeth, and vertical defects were found only in 264 (7.8%) of the teeth, which was statistically significant (P<.001). Search of the selected journals revealed 477 papers have addressed the treatment modalities for vertical and horizontal types of bone loss specifically. Out of the 477 papers, 461 (96.3%) have addressed vertical bone loss, and 18 (3.7%) have addressed treatment options for horizontal bone loss. Two papers have addressed both types of bone loss and are included in both categories. Conclusion: Horizontal bone loss is more prevalent than vertical bone loss but has been sidelined by researchers as very few papers have been published on the subject of regenerative treatment modalities for

  20. Horizontal bone augmentation: the decision tree.

    Science.gov (United States)

    Fu, Jia-Hui; Wang, Hom-Lay

    2011-01-01

    The emergence of implant dentistry has led to the need for bone augmentation procedures. With the removal of a tooth, there is an inevitable three-dimensional (3D) loss of alveolar bone. More often than not, horizontal bone loss occurs at a faster rate and to a greater extent compared to vertical bone loss. This led to the development of several horizontal bone augmentation techniques, such as guided bone regeneration, ridge expansion, distraction osteogenesis, and block grafts. These proposed augmentation techniques aim to place the implant in an ideal 3D position for successful restorative therapy. The literature has shown that horizontal bone augmentation is fairly predictable if certain criteria are fulfilled. However, with numerous techniques and materials currently available, it is difficult to choose the most suitable treatment modality. A search of the literature available was conducted to validate the decision-making process when planning for a horizontal ridge augmentation procedure. The decision tree proposed in this paper stems from the 3D buccolingual bone width available at the site of implant placement (⋝ 3.5 mm, factors such as the tissue thickness, the arch position, and the availability of autogenous bone. The decision tree provides insight on how clinicians can choose the most appropriate and predictable horizontal ridge augmentation procedure to minimize unnecessary complications.

  1. Characterization of horizontal air–water two-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Ran; Kim, Seungjin, E-mail: skim@psu.edu

    2017-02-15

    Highlights: • A visualization study is performed to develop flow regime map in horizontal flow. • Database in horizontal bubbly flow is extended using a local conductivity probe. • Frictional pressure drop analysis is performed in horizontal bubbly flow. • Drift flux analysis is performed in horizontal bubbly flow. - Abstract: This paper presents experimental studies performed to characterize horizontal air–water two-phase flow in a round pipe with an inner diameter of 3.81 cm. A detailed flow visualization study is performed using a high-speed video camera in a wide range of two-phase flow conditions to verify previous flow regime maps. Two-phase flows are classified into bubbly, plug, slug, stratified, stratified-wavy, and annular flow regimes. While the transition boundaries identified in the present study compare well with the existing ones (Mandhane et al., 1974) in general, some discrepancies are observed for bubbly-to-plug/slug, and plug-to-slug transition boundaries. Based on the new transition boundaries, three additional test conditions are determined in horizontal bubbly flow to extend the database by Talley et al. (2015a). Various local two-phase flow parameters including void fraction, interfacial area concentration, bubble velocity, and bubble Sauter mean diameter are obtained. The effects of increasing gas flow rate on void fraction, bubble Sauter mean diameter, and bubble velocity are discussed. Bubbles begin to coalesce near the gas–liquid layer instead of in the highly packed region when gas flow rate increases. Using all the current experimental data, two-phase frictional pressure loss analysis is performed using the Lockhart–Martinelli method. It is found that the coefficient C = 24 yields the best agreement with the data with the minimum average difference. Moreover, drift flux analysis is performed to predict void-weighted area-averaged bubble velocity and area-averaged void fraction. Based on the current database, functional

  2. HORIZONTAL WELL DRILL-IN FLUIDS

    Directory of Open Access Journals (Sweden)

    Nediljka Gaurina-Međimurec

    1998-12-01

    Full Text Available Main objective of horizontal driling is to place a drain-hole for a long distance within the pay zone to enhance productivity or injectivity. In drilling horizontal wells, more serious problems appear than in drilling vertical wells. These problems are: poor hole cleaning, excessive torque and drag, hole filling, pipe stucking, wellbore instability, loss of circulation, formation damage, poor cement job, and difficulties at logging jobs. From that reason, successful drilling and production of horizontal well depends largely on the fluid used during drilling and completion phases. Several new fluids, that fulfill some or all of required properties (hole cleaning, cutting suspension, good lubrication, and relative low formation damage, are presented in this paper.

  3. Horizontal bridges in polar dielectric liquids

    Energy Technology Data Exchange (ETDEWEB)

    Woisetschlaeger, Jakob [Graz University of Technology, Experimental Turbomachinery Research and Optical Measurement Group, Institute for Thermal Turbomachinery and Machine Dynamics, Graz (Austria); Wexler, Adam D.; Fuchs, Elmar C. [Wetsus, Center of Excellence for Sustainable Water Technology, Leeuwarden (Netherlands); Holler, Gert [Graz University of Technology, Institute of Electrical Measurement and Measurement Signal Processing, Graz (Austria); Eisenhut, Mathias [Graz University of Technology, Institute of Analytical Chemistry and Food Chemistry, Graz (Austria); Gatterer, Karl [Graz University of Technology, Institute of Physical and Theoretical Chemistry, Graz (Austria)

    2012-01-15

    When a high-voltage direct-current is applied to two beakers filled with polar liquid dielectrica like water or methanol, a horizontal bridge forms between the two beakers. By repeating a version of Pellat's experiment, it is shown that a horizontal bridge is stable by the action of electrohydrodynamic pressure. Thus, the static and dynamic properties of the phenomenon called a 'floating water bridge' can be explained by the gradient of Maxwell pressure, replenishing the liquid within the bridge against any drainage mechanism. It is also shown that a number of liquids can form stable and long horizontal bridges. The stability of such a connection, and the asymmetry in mass flow through such bridges caused by the formation of ion clouds in the vicinity of the electrodes, is also discussed by two further experiments. (orig.)

  4. Is horizontal transmission really a problem for phylogenetic comparative methods? A simulation study using continuous cultural traits

    Science.gov (United States)

    Currie, Thomas E.; Greenhill, Simon J.; Mace, Ruth

    2010-01-01

    Phylogenetic comparative methods (PCMs) provide a potentially powerful toolkit for testing hypotheses about cultural evolution. Here, we build on previous simulation work to assess the effect horizontal transmission between cultures has on the ability of both phylogenetic and non-phylogenetic methods to make inferences about trait evolution. We found that the mode of horizontal transmission of traits has important consequences for both methods. Where traits were horizontally transmitted separately, PCMs accurately reported when trait evolution was not correlated even at the highest levels of horizontal transmission. By contrast, linear regression analyses often incorrectly concluded that traits were correlated. Where simulated trait evolution was not correlated and traits were horizontally transmitted as a pair, both methods inferred increased levels of positive correlation with increasing horizontal transmission. Where simulated trait evolution was correlated, increasing rates of separate horizontal transmission led to decreasing levels of inferred correlation for both methods, but increasing rates of paired horizontal transmission did not. Furthermore, the PCM was also able to make accurate inferences about the ancestral state of traits. These results suggest that under certain conditions, PCMs can be robust to the effects of horizontal transmission. We discuss ways that future work can investigate the mode and tempo of horizontal transmission of cultural traits. PMID:21041214

  5. Inter-rater reliability of the Berg Balance Scale, 30 s chair stand test and 6 m walking test, and construct validity of the Berg Balance Scale in nursing home residents with mild-to-moderate dementia.

    Science.gov (United States)

    Telenius, Elisabeth Wiken; Engedal, Knut; Bergland, Astrid

    2015-09-07

    When testing physical function, patients must be alert and have the capacity to understand and respond to instructions. Patients with dementia may have difficulties fulfilling these requirements and, therefore, the reliability of the measures may be compromised. We aimed to assess the inter-rater reliability between pairs of observers independently rating the participant in the Berg Balance Scale (BBS), 30 s chair stand test (CST) and 6 m walking test. We also wanted to investigate the internal consistency of the BBS. Cross-sectional study. We included 33 nursing home patients with a mild-to-moderate degree of dementia and tested them once with two evaluators present. One evaluator gave instructions and both evaluators scored the patients' performance. Weighted κ, intraclass correlation coefficient (ICC) model 2.1 with 95% CIs and minimal detectable change (MDC) were used to measure inter-rater reliability. Cronbach's α was calculated to evaluate the internal consistency of the BBS sum score. The mean values of the BBS scored by the two evaluators were 38±13.7 and 38.0±13.8, respectively. Weighted κ scores for the BBS items varied from 0.83 to 1.0. ICC for the BBS's sum score was 0.99, and the MDC was 2.7% and 7%, respectively. The Cronbach's α of the BBS's sum score was 0.9. The ICC of the CST and 6 m walking test was 1 and 0.97, respectively. The MDC on the 6 m walking test was 0.08% and 15.2%, respectively. The results reveal an excellent relative inter-rater reliability of the BBS, CST and 6 m walking test as well as high internal consistency for the BBS in a population of nursing home residents with mild-to-moderate dementia. The absolute reliability was 2.7 on the BBS and 0.08 on the 6 m walking test. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  6. Fourth international seminar on horizontal steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Tuomisto, H. [ed.] [IVO Group, Vantaa (Finland); Purhonen, H. [ed.] [VTT, Espoo (Finland); Kouhia, V. [ed.] [Lappeenranta Univ. of Technology (Finland)

    1997-12-31

    The general objective of the International Seminars of Horizontal Steam Generator Modelling has been the improvement in understanding of realistic thermal hydraulic behaviour of the generators when performing safety analyses for VVER reactors. The main topics presented in the fourth seminar were: thermal hydraulic experiments and analyses, primary collector integrity, feedwater distributor replacement, management of primary-to-secondary leakage accidents and new developments in the VVER safety technology. The number of participants, representing designers and manufacturers of the horizontal steam generators, plant operators, engineering companies, research organizations, universities and regulatory authorities, was 70 from 10 countries.

  7. Gender-based differences in the cardiovascular response to standing

    Science.gov (United States)

    Gotshall, Robert W.; Tsai, Pai-Feng; Frey, Mary A. B.

    1991-01-01

    The cardiovascular responses of men and women to the stand test were compared by measuring respective values for heart rate, blood pressure, stroke volume, cardiac output, and total peripheral resistance during a 5-min supine and a 5-min standing test in ten subjects of each gender. It was found that, while the male and female subjects had similar heart rate values, all other responses exhibited greater changes in men than in women. While differences in the height of the subjects did not account for differences in cardiovascular responses, no mechanism responsible for these differences could be identified.

  8. NEW TECHNOLOGIES IN MEASUREMENT OF STANDING LONG JUMP

    Directory of Open Access Journals (Sweden)

    Ratko Stanković

    2008-08-01

    Full Text Available On the sample of 21 students of Faculty of sports and physical education, age 21±6 months, measurement of standing long jump length by using test for explosive puissance estimation of lower extremities was effected. Test was recorded by digital video camera, and all conditions for application of video analyses i.e. kinematics methods were present. After digitalization, record was mistreated and prepared for further manipulating by using appropriate software for video analyses. Four different persons measured jump length (4 items. Metric characteristics of standing long jump showed high signifi cation level.

  9. Comparing reading speed for horizontal and vertical English text.

    Science.gov (United States)

    Yu, Deyue; Park, Heejung; Gerold, David; Legge, Gordon E

    2010-02-23

    There are three formats for arranging English text for vertical reading-upright letters arranged vertically (marquee), and horizontal text rotated 90 degrees clockwise or counterclockwise. Previous research has shown that reading is slower for all three vertical formats than for horizontal text, with marquee being slowest (M. D. Byrne, 2002). It has been proposed that the size of the visual span-the number of letters recognized with high accuracy without moving the eyes-is a visual factor limiting reading speed. We predicted that reduced visual-span size would be correlated with the slower reading for the three vertical formats. We tested this prediction with uppercase and lowercase letters. Reading performance was measured using two presentation methods: RSVP (Rapid Serial Visual Presentation) and flashcard (a block of text on four lines). On average, reading speed for horizontal text was 139% faster than marquee text and 81% faster than the rotated texts. Size of the visual span was highly correlated with changes in reading speed for both lowercase and uppercase letters and for both RSVP and flashcard reading. Our results are consistent with the view that slower reading of vertical text is due to a decrease in the size of the visual span for vertical reading.

  10. Horizontal transfer of carbohydrate metabolism genes into ectomycorrhizal Amanita.

    Science.gov (United States)

    Chaib De Mares, Maryam; Hess, Jaqueline; Floudas, Dimitrios; Lipzen, Anna; Choi, Cindy; Kennedy, Megan; Grigoriev, Igor V; Pringle, Anne

    2015-03-01

    The genus Amanita encompasses both symbiotic, ectomycorrhizal fungi and asymbiotic litter decomposers; all species are derived from asymbiotic ancestors. Symbiotic species are no longer able to degrade plant cell walls. The carbohydrate esterases family 1 (CE1s) is a diverse group of enzymes involved in carbon metabolism, including decomposition and carbon storage. CE1 genes of the ectomycorrhizal A. muscaria appear diverged from all other fungal homologues, and more similar to CE1s of bacteria, suggesting a horizontal gene transfer (HGT) event. In order to test whether AmanitaCE1s were acquired horizontally, we built a phylogeny of CE1s collected from across the tree of life, and describe the evolution of CE1 genes among Amanita and relevant lineages of bacteria. CE1s of symbiotic Amanita were very different from CE1s of asymbiotic Amanita, and are more similar to bacterial CE1s. The protein structure of one CE1 gene of A. muscaria matched a depolymerase that degrades the carbon storage molecule poly((R)-3-hydroxybutyrate) (PHB). Asymbiotic Amanita do not carry sequence or structural homologues of these genes. The CE1s acquired through HGT may enable novel metabolisms, or play roles in signaling or defense. This is the first evidence for the horizontal transfer of carbohydrate metabolism genes into ectomycorrhizal fungi. © 2014 The Authors New Phytologist © 2014 New Phytologist Trust.

  11. Mechanized stand treatment in young stands - stress and strain on the machine operator

    Energy Technology Data Exchange (ETDEWEB)

    Gellerstedt, S. [Swedish Univ. of Agricultural Sciences, Garpenberg (Sweden). Dept. of Operational Efficiency

    1996-12-31

    An analysis of mechanized spacing and cleaning was carried out in order to understand why, how and when the operator gather information; to understand which mental processes the operator use, as well as how he execute the physical work and how he gets feed-back from the work. Description of the work and its influence on the operator`s reactions is based on interviews, time-studies, the analysis of video films as well as on observations. The operator`s heart rate variability was measured as an indicator of mental effort. The electrical activity in the trapezius muscle was measured and analyzed with consideration to breaks. There are many work elements which call for the operator`s attention. The managing of the machine occupy the attention while biological assessments are needed. The limited sight hampers the operator possibility to quickly grasp the necessary information about the young tree stand and the terrain. The intense operation of the crane caused few pauses (emg-gaps) in the trapezius muscle. The low heart rate variability indicated a high mental workload, probably explained by high concentration. Proposals for technical development are given. A better sight, more `sensibility` of the cleaning head and aids for orientation would give the operator more efficient information. A partly robotized crane, a turnable cabin which adjusts its horizontal position automatically and better absorbs the vibrations, would give a more relaxed working environment. 14 refs , 3 figs, 4 tabs

  12. Transpalpebral eye enucleation in the standing horse

    DEFF Research Database (Denmark)

    Christophersen, Mogens Teken

    Transpalpebral eye enucleation in the standing horse. The Nordic Equine Veterinary Conference, Proceedings, Copenhagen. Denmark. Nov. 2011.......Transpalpebral eye enucleation in the standing horse. The Nordic Equine Veterinary Conference, Proceedings, Copenhagen. Denmark. Nov. 2011....

  13. Flow mapping for ESS horizontal target

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Y.; Kikura, H.; Taishi, T. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    Flow behaviour for ESS horizontal target is studied experimentally using two dimensional water model. A velocity field of stationary flow in reaction zone has been obtained. Three dimensional effect was also studied as a spanwise flow structure. (author) 3 figs., 3 refs.

  14. Horizontal transfer of a plant transposon.

    Directory of Open Access Journals (Sweden)

    Xianmin Diao

    2006-01-01

    Full Text Available The majority of well-documented cases of horizontal transfer between higher eukaryotes involve the movement of transposable elements between animals. Surprisingly, although plant genomes often contain vast numbers of these mobile genetic elements, no evidence of horizontal transfer of a nuclear-encoded transposon between plant species has been detected to date. The most mutagenic known plant transposable element system is the Mutator system in maize. Mu-like elements (MULEs are widespread among plants, and previous analysis has suggested that the distribution of various subgroups of MULEs is patchy, consistent with horizontal transfer. We have sequenced portions of MULE transposons from a number of species of the genus Setaria and compared them to each other and to publicly available databases. A subset of these elements is remarkably similar to a small family of MULEs in rice. A comparison of noncoding and synonymous sequences revealed that the observed similarity is not due to selection at the amino acid level. Given the amount of time separating Setaria and rice, the degree of similarity between these elements excludes the possibility of simple vertical transmission of this class of MULEs. This is the first well-documented example of horizontal transfer of any nuclear-encoded genes between higher plants.

  15. Horizontal Transfer of a Plant Transposon.

    Directory of Open Access Journals (Sweden)

    2005-12-01

    Full Text Available The majority of well-documented cases of horizontal transfer between higher eukaryotes involve the movement of transposable elements between animals. Surprisingly, although plant genomes often contain vast numbers of these mobile genetic elements, no evidence of horizontal transfer of a nuclear-encoded transposon between plant species has been detected to date. The most mutagenic known plant transposable element system is the Mutator system in maize. Mu-like elements (MULEs are widespread among plants, and previous analysis has suggested that the distribution of various subgroups of MULEs is patchy, consistent with horizontal transfer. We have sequenced portions of MULE transposons from a number of species of the genus Setaria and compared them to each other and to publicly available databases. A subset of these elements is remarkably similar to a small family of MULEs in rice. A comparison of noncoding and synonymous sequences revealed that the observed similarity is not due to selection at the amino acid level. Given the amount of time separating Setaria and rice, the degree of similarity between these elements excludes the possibility of simple vertical transmission of this class of MULEs. This is the first well-documented example of horizontal transfer of any nuclear-encoded genes between higher plants.

  16. Determinants Of Vertical And Horizontal Export Diversification ...

    African Journals Online (AJOL)

    This implies that not all types of natural resource endowment have a 'Dutch disease' effect. While inflation, exchange rate, and foreign aid variables have a mixed effect on vertical and horizontal export diversification, political instability however has a strong adverse effect on export diversification; especially for SSA. The key ...

  17. Horizontal Axis Levitron--A Physics Demonstration

    Science.gov (United States)

    Michaelis, Max M.

    2014-01-01

    After a brief history of the Levitron, the first horizontal axis Levitron is reported. Because it is easy to operate, it lends itself to educational physics experiments and analogies. Precession and nutation are visualized by reflecting the beam from a laser pointer off the "spignet". Precession is fundamental to nuclear magnetic…

  18. Third international seminar on horizontal steam generators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The Third International Seminar on Horizontal Steam Generators held on October 18-20, 1994 in Lappeenranta, consisted of six sessions dealing with the topics: thermal hydraulic experiments and analyses, primary collector integrity, management of primary-to-secondary leakage accidents, feedwater collector replacement and discussion of VVER-440 steam generator safety issues.

  19. Parametric study for horizontal steam generator modelling

    Energy Technology Data Exchange (ETDEWEB)

    Ovtcharova, I. [Energoproekt, Sofia (Bulgaria)

    1995-12-31

    In the presentation some of the calculated results of horizontal steam generator PGV - 440 modelling with RELAP5/Mod3 are described. Two nodalization schemes have been used with different components in the steam dome. A study of parameters variation on the steam generator work and calculated results is made in cases with separator and branch.

  20. Teaching Activities on Horizontal Nuclear Proliferation.

    Science.gov (United States)

    Zola, John

    1990-01-01

    Provides learning activities concerning the horizontal proliferation of nuclear weapons. Includes step-by-step directions for four activities: (1) the life cycle of nuclear weapons; (2) nuclear nonproliferation: pros and cons; (3) the nuclear power/nuclear weapons connection; and (4) managing nuclear proliferation. (NL)

  1. Horizontal gene transfer in the phytosphere

    NARCIS (Netherlands)

    Elsas, van J.D.; Turner, S.; Bailey, M.J.

    2003-01-01

    Here, the ecological aspects of gene transfer processes between bacteria in the phytosphere are examined in the context of emerging evidence for the dominant role that horizontal gene transfer (HGT) has played in the evolutionary shaping of bacterial communities. Moreover, the impact of the putative

  2. Detecting Highways of Horizontal Gene Transfer

    Science.gov (United States)

    Bansal, Mukul S.; Gogarten, J. Peter; Shamir, Ron

    In a horizontal gene transfer (HGT) event a gene is transferred between two species that do not share an ancestor-descendant relationship. Typically, no more than a few genes are horizontally transferred between any two species. However, several studies identified pairs of species between which many different genes were horizontally transferred. Such a pair is said to be linked by a highway of gene sharing. We present a method for inferring such highways. Our method is based on the fact that the evolutionary histories of horizontally transferred genes disagree with the corresponding species phylogeny. Specifically, given a set of gene trees and a trusted rooted species tree, each gene tree is first decomposed into its constituent quartet trees and the quartets that are inconsistent with the species tree are identified. Our method finds a pair of species such that a highway between them explains the largest (normalized) fraction of inconsistent quartets. For a problem on n species, our method requires O(n 4) time, which is optimal with respect to the quartets input size. An application of our method to a dataset of 1128 genes from 11 cyanobacterial species, as well as to simulated datasets, illustrates the efficacy of our method.

  3. Horizontal gene transfer and bacterial diversity

    Indian Academy of Sciences (India)

    Unknown

    introduction of novel physiological traits from distantly related organisms, horizontal gene transfer often causes drastic changes in the ecological ..... degradation by host restriction endonucleases. (iii) Conjugation: In this mechanism, ... mosome, formation of a conjugative bridge and trans- position into the recipient strain.

  4. comparative evaluation of pressure distribution between horizontal ...

    African Journals Online (AJOL)

    user

    Green and source function were used to evaluate the performance of horizontal well and vertical well, eventually, compared based dimensionless pressures and pressure derivatives computed by varying the reservoir geometry. Results presented as type curves show that the rate of decline of the pressure derivative curve is.

  5. Comparative evaluation of pressure distribution between horizontal ...

    African Journals Online (AJOL)

    Green and source function were used to evaluate the performance of horizontal well and vertical well, eventually, compared based dimensionless pressures and pressure derivatives computed by varying the reservoir geometry. Results presented as type curves show that the rate of decline of the pressure derivative curve is ...

  6. Cleanup/stimulation of a horizontal wellbore using propellants. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rougeot, J.E.; Lauterbach, K.A.

    1993-01-01

    This report documents the stimulation/cleanup of a horizontal well bore (Wilson 25) using propellants. The Wilson 25 is a Bartlesville Sand well located in the Flatrock Field, Osage County, Oklahoma. The Wilson 25 was drilled to determine if horizontal drilling could be used as a means to economically recover primary oil that had been left in place in a mostly abandoned oil field because of the adverse effects of water coning. Pump testing of the Wilson 25 horizontal well bore before cleanup or stimulation produced 6 barrels of oil and .84 barrels of water per day. The high percentage of daily oil production to total daily fluid production indicated that the horizontal well bore had accessed potentially economical oil reserves if the fluid production rate could be increased by performing a cleanup/stimulation treatment. Propellants were selected as an inexpensive means to stimulate and cleanup the near well bore area in a uniform manner. The ignition of a propellant creates a large volume of gas which penetrates the formation, creating numerous short cracks through which hydrocarbons can travel into the well bore. More conventional stimulation/cleanup techniques were either significantly more expensive, less likely to treat uniformly, or could not be confined to the near well bore area. Three different propellant torpedo designs were tested with a total of 304` of horizontal well bore being shot and producible. The initial test shot caused 400` of the horizontal well bore to become plugged off, and subsequently it could not be production tested. The second and third test shots were production tested, with the oil production being increased 458% and 349%, respectively, on a per foot basis. The Wilson 25 results indicate that a propellant shot treatment is an economically viable means to cleanup/stimulate a horizontal well bore.

  7. 21 CFR 203.35 - Standing requests.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Standing requests. 203.35 Section 203.35 Food and... PRESCRIPTION DRUG MARKETING Samples § 203.35 Standing requests. Manufacturers or authorized distributors of record shall not distribute drug samples on the basis of open-ended or standing requests, but shall...

  8. Job satisfaction and horizontal violence in hospital staff registered nurses: the mediating role of peer relationships.

    Science.gov (United States)

    Purpora, Christina; Blegen, Mary A

    2015-08-01

    To describe the association between horizontal violence and job satisfaction in hospital staff registered nurses and the degree to which peer relationships mediates the relationship. Additionally, the association between nurse and work characteristics and job satisfaction were determined. Horizontal violence is a major predictor of nurses' job satisfaction. Yet, not enough is known about the relationship between these variables. Job satisfaction is an important variable to study because it is a predictor of patient care quality and safety internationally. Peer relationships, a job satisfier for nurses, was identified as a potential mediator in the association between horizontal violence and job satisfaction. Cross-sectional mediational model testing. An anonymous four-part survey of a random sample of 175 hospital staff registered nurses working in California provided the data. Data about horizontal violence, peer relationships, job satisfaction, and nurse and work characteristics were collected between March-August 2010. A statistically significant negative relationship was found between horizontal violence and peer relationships, job satisfaction and a statistically significant positive relationship was found between peer relationships and job satisfaction. Peer relationships mediated the association between horizontal violence and job satisfaction. Job satisfaction was reported as higher by nurses who worked in teaching hospitals. There were no statistically significant differences in job satisfaction based on gender, ethnicity, basic registered nurse education, highest degree held, size of hospital or clinical area. The results suggest that peer relationships can attenuate the negative relationship between horizontal violence and job satisfaction. This adds to the extant literature on the relationship between horizontal violence and job satisfaction. The findings highlight peer relationships as an important factor when considering effective interventions that

  9. Vertical force and wrist deviation angle when using a walker to stand up and sit down.

    Science.gov (United States)

    Leung, Cherng-Yee; Yeh, Po-Chan

    2011-08-01

    Research investigating walkers suggests that safety and assistance for the elderly with weak lower limbs were important. However, the relationship between the use of a walker and the upper limbs has received little investigation. Standing up and sitting down are important daily activities. Therefore, the aim of this study was to explore wrist deviation and vertical force among elderly individuals using a walker for assistance to stand up and sit down. In total, 64 elderly volunteers (M age = 80.22, SD = 9.36) were enrolled. Data were obtained from four load cells and a twin-axis wrist goniometer. Wrist deviation and vertical force were examined when participants used a walker with horizontal handles to assist in standing up and sitting down. Significant wrist angle deviation occurred with the use of a walker, with dorsiflexion of the right hand greater than that of the left. Males exerted significantly greater vertical force. In the sitting position, greater ulnar deviation was seen among experienced walker users, whereas during standing, experienced users exhibited greater dorsiflexion. The horizontal handles of most marketed walkers may cause user wrist deviations, suggesting researchers should pursue improvements in walker design.

  10. Standing Stability in Knee Osteoarthritis Patients

    Directory of Open Access Journals (Sweden)

    M.T. Karimi

    2016-09-01

    Full Text Available Aims: Being prevalent in the more than 40 years old persons, the knee osteoarthritis is one of the main factors in the function system failure mainly affecting their life. There is a type of instability in the persons with knee osteoarthritis, which is an increase in the domain and frequency of body pressure center. The aim of the present study was to compare the standing stability parameters in persons with knee osteoarthritis and healthy persons. Instrument & Methods: In this case-control, 15 patients with knee osteoarthritis referred to the physiotherapy clinic of the rehabilitation center and Al-Zahra hospital were studied in the muscle-skeletal research center of Isfahan University of Medical Sciences in 2015. The subjects were selected via stratified sampling method. As control group, 15 healthy persons were also studied in Isfahan. Total path length and the domain and frequency of pressure center in different directions were measured to assess the stability. Data was analyzed by SPSS 19 software using descriptive statistics and paired T test. Findings: There were increases in the mean movement domain and the frequency of pressure center in the anterior-posterior and the internal-external directions, as well as in the total path proceeded by the pressure center in the internal-external direction, in the persons with knee osteoarthritis than the healthy persons (p0.05. Conclusion: Standing stability and balance in persons with knee osteoarthritis decreases compared to healthy persons.

  11. Design Considerations for Stand-Alone Photovoltaic (PV Cell Applications

    Directory of Open Access Journals (Sweden)

    Mehmet Cebeci

    2013-06-01

    Full Text Available Solar energy is one of the most important renewable energy sources. The photovoltaic (PV cell systems are used to convert solar energy into electricity. PV systems are divided into two as fixed systems and tracking systems. Fixed systems are mounted at a certain tilt with horizontal to make full use of sunlight. The tilt angle of PV arrays in a fixed system depends on the location and time. If this tilt angle is determined well, the amount of insolation and the energy that is generated increases. When a stand-alone PV cell system is being chosen, certain design operations should be implemented. The number of modules and batteries needed for any system should be calculated by means of the amount of load, insolation level, module characteristics, etc. The design of system is finalized according to the energy demand.

  12. Stand structure and dead wood characterization in cork forest of Calabria region (southern Italy

    Directory of Open Access Journals (Sweden)

    Barreca L

    2010-07-01

    Full Text Available The cork forests are one the most interesting forest ecosystems in the Mediterranean area. Their distribution and ecological characteristics have undergone a significant transformation after the significant changes following the development and establishment of agricultural crops. Currently, only a few stands, which survive in hard to reach places, prove the wide spread distribution of this species was also in the recent past. This study describes the stand structure of some cork forests in Calabria region (southern Italy. In order, to characterize the vertical structure Latham index has been applied, while for the description of the horizontal distribution NBSI group indices has been used. Detailed surveys on dead wood were also conducted determining the occurring volume and its decay stage according to the decay classes system proposed by Hunter. The aim of this study is to provide guidelines for sustainable management of cork forests, improving and promoting the structural complexity and functional efficiency of these forest stands.

  13. The interactive impact of forest site and stand attributes and logging technology on stand management

    Science.gov (United States)

    C.B. LeDoux; J.E. Baumgras

    1991-01-01

    The impact of selected site and stand attributes on stand management is demonstrated using actual forest model plot data and a complete systems simulation model called MANAGE. The influence of terrain on the type of logging technology required to log a stand and the resulting impact on stand management is also illustrated. The results can be used by managers and...

  14. Effects of horizontal acceleration on the superconducting gravimeter CT #036 at Ishigakijima, Japan

    Science.gov (United States)

    Imanishi, Yuichi; Nawa, Kazunari; Tamura, Yoshiaki; Ikeda, Hiroshi

    2018-01-01

    In the gravity sensor of a superconducting gravimeter, a superconducting sphere as a test mass is levitated in a magnetic field. Such a sensor is susceptible to applied horizontal as well as vertical acceleration, because the translational degrees of freedom of the mass are not perfectly limited to the vertical direction. In the case of the superconducting gravimeter CT #036 installed at Ishigakijima, Japan, horizontal ground acceleration excited by the movements of a nearby VLBI antenna induces systematic step noise within the gravity recordings. We investigate this effect in terms of the static and dynamic properties of the gravity sensor using data from a collocated seismometer. It is shown that this effect can be effectively modeled by the coupling between the horizontal and vertical components in the gravity sensor. It is also found that the mechanical eigenfrequency for horizontal translation of the levitating sphere is approximately 3 Hz.[Figure not available: see fulltext.

  15. The one-leg standing radiograph

    OpenAIRE

    Pinsornsak, P.; Naratrikun, K.; Kanitnate, S.; Sangkomkamhang, T.

    2016-01-01

    Objectives The purpose of this study was to compare the joint space width between one-leg and both-legs standing radiographs in order to diagnose a primary osteoarthritis of the knee. Methods Digital radiographs of 100 medial osteoarthritic knees in 50 patients were performed. The patients had undergone one-leg standing anteroposterior (AP) views by standing on the affected leg while a both-legs standing AP view was undertaken while standing on both legs. The severity of the osteoarthritis wa...

  16. Condensation of Refrigerant-11 on the outside of horizontal and inclined enhanced tubes

    Energy Technology Data Exchange (ETDEWEB)

    Domingo, N.

    1982-12-01

    Heat transfer condensation tests with Refrigerant-11 were performed on the outside of a smooth tube and a variety of enhanced tubes oriented horizontally and at various tube inclinations. One smooth tube and seven enhanced (externally fluted, roped, spiraled, and externally finned) tubes of 2.54-cm (1-in.) nominal outside diameter and 1.17-m (4-ft) length were tested. Several of the tested tubes featured internal enhanced geometries, which were caused by the heat transfer enhancing geometry on the tube's external surface. Condensing heat transfer coefficients are reported as composite coefficients, which combine the resistance of the condensing film and the tube wall, and are based on total tube outside surface area. Results show that in the horizontal condensing mode, the rank order (best to worst) of the tube geometries tested was spiral-shaped tubes, rope-shaped tubes, smooth tube, externally finned tube, and externally fluted tube. For a spiral-shaped tube, horizontal composite coefficients were up to 2.0 times the corresponding horizontal smooth tube values. For tilt angles greater than or equal to 60/sup 0/ from the horizontal, the condensing performance of the externally fluted tube was best of all the tubes tested.

  17. Standing Up for Learning: A Pilot Investigation on the Neurocognitive Benefits of Stand-Biased School Desks

    Directory of Open Access Journals (Sweden)

    Ranjana K. Mehta

    2015-12-01

    Full Text Available Standing desks have proven to be effective and viable solutions to combat sedentary behavior among children during the school day in studies around the world. However, little is known regarding the potential of such interventions on cognitive outcomes in children over time. The purpose of this pilot study was to determine the neurocognitive benefits, i.e., improvements in executive functioning and working memory, of stand-biased desks and explore any associated changes in frontal brain function. 34 freshman high school students were recruited for neurocognitive testing at two time points during the school year: (1 in the fall semester and (2 in the spring semester (after 27.57 (1.63 weeks of continued exposure. Executive function and working memory was evaluated using a computerized neurocognitive test battery, and brain activation patterns of the prefrontal cortex were obtained using functional near infrared spectroscopy. Continued utilization of the stand-biased desks was associated with significant improvements in executive function and working memory capabilities. Changes in corresponding brain activation patterns were also observed. These findings provide the first preliminary evidence on the neurocognitive benefits of standing desks, which to date have focused largely on energy expenditure. Findings obtained here can drive future research with larger samples and multiple schools, with comparison groups that may in turn implicate the importance of stand-biased desks, as simple environmental changes in classrooms, on enhancing children’s cognitive functioning that drive their cognitive development and impact educational outcomes.

  18. Adjustable recessions in horizontal comitant strabismus: A pilot study

    Directory of Open Access Journals (Sweden)

    Siddharth Agrawal

    2015-01-01

    Full Text Available Aim: To compare the surgical outcome of adjustable with the conventional recession in patients with horizontal comitant strabismus. Patients and Methods: A prospective comparative nonrandomized interventional pilot study was performed on patients with horizontal comitant strabismus. Fifty-four patients (27 in each group were allocated into 2 groups to undergo either adjustable suture (AS recession or non-AS (NAS recession along with conventional resection. The patients were followed up for 6 months. A successful outcome was defined as deviation ±10 prism diopters at 6 months. The results were statistically analyzed by Chi-square test, Fisher′s exact test, and Student′s t-test. Results: A successful outcome was found in 24 (88.8% patients in AS and 17 (62.9% in NAS group (P = 0.02. The postoperative adjustment was done in 13 (48.1% patients in AS group. There was one complication (tenon′s cyst in AS group. Conclusion: AS recession may be considered in all cooperative patients undergoing strabismus surgery for comitant deviations.

  19. Relative size and stand age determine Pinus banksiana mortality

    Science.gov (United States)

    Han Y. H. Chen; Songling Fu; Robert A. Monserud; Ian C. Gillies

    2008-01-01

    Tree mortality is a poorly understood process in the boreal forest. Whereas large disturbances reset succession by killing all or most trees, background tree mortality was hypothesized to be affected by competition, ageing, and stand composition. We tested these hypotheses on jack pine (Pinus banksiana Lamb.) mortality using data from long-term...

  20. Infrared differential absorption lidar for stand-off detection of ...

    Indian Academy of Sciences (India)

    2014-02-14

    Feb 14, 2014 ... bon dioxide laser-based differential absorption lidar (DIAL) system capable of stand-off detection of chemical clouds in ... technical details of trolley-mounted CO2 DIAL system and the data generated during the test and evaluation of this sensor using ... High-energy pulses of laser. Pramana – J. Phys., Vol.

  1. Consistent definition and application of Reineke's Stand Density Index in silviculture and stand projection

    Science.gov (United States)

    John D. Shaw; James N. Long

    2010-01-01

    Reineke’s Stand Density Index (SDI) has been available to silviculturists for over 75 years, but application of this stand metric has been inconsistent. Originally described as a measurement of relative density in single-species, even-aged stands, it has since been generalized for use in uneven-aged stands and mixed-species stands. However, methods used to establish...

  2. Horizontal gene transfer between bacteria and animals

    Science.gov (United States)

    Dunning Hotopp, Julie C.

    2011-01-01

    Horizontal gene transfer is increasingly described between bacteria and animals. Such transfers that are vertically inherited have the potential to influence the evolution of animals. One classic example is the transfer of DNA from mitochondria and chloroplasts to the nucleus after the acquisition of these organelles by eukaryotes. Even today, many of the described instances of bacteria to animal transfer occur as part of intimate relationships like those of endosymbionts and their invertebrate hosts, particularly insects and nematodes, while numerous transfers are also found in asexual animals. Both of these observations are consistent with modern evolutionary theory, in particular the serial endosymbiotic theory and Muller’s ratchet. While it is tempting to suggest that these particular lifestyles might promote horizontal gene transfer, it is difficult to ascertain given the non-random sampling of animal genome sequencing projects and the lack of a systematic analysis of animal genomes for such transfers. PMID:21334091

  3. Study on Horizontally Polarized Omnidirectional Microstrip Antenna

    Directory of Open Access Journals (Sweden)

    Kun Wei

    2016-01-01

    Full Text Available A horizontally polarized omnidirectional microstrip antenna is proposed in this paper. The structure of designed antenna is with two back-to-back horizontally polarized microstrip antenna elements. Gain variation on main radiation plane of this new antenna is analyzed and radiation theory is deduced; formula of directivity on main radiation plane is given. Better omnidirectional characteristic of this antenna can be obtained by decreasing patch physical length. Both simulated and measured results verify the omnidirectional radiation patterns and input impedance characteristics. Good omnidirectional radiation patterns (gain variation in E-plane less than ±0.4 dBi and input impedance characteristics are obtained; moreover, cross polarization less than −20 dBi is achieved.

  4. Horizontal modular dry irradiated fuel storage system

    Science.gov (United States)

    Fischer, Larry E.; McInnes, Ian D.; Massey, John V.

    1988-01-01

    A horizontal, modular, dry, irradiated fuel storage system (10) includes a thin-walled canister (12) for containing irradiated fuel assemblies (20), which canister (12) can be positioned in a transfer cask (14) and transported in a horizontal manner from a fuel storage pool (18), to an intermediate-term storage facility. The storage system (10) includes a plurality of dry storage modules (26) which accept the canister (12) from the transfer cask (14) and provide for appropriate shielding about the canister (12). Each module (26) also provides for air cooling of the canister (12) to remove the decay heat of the irradiated fuel assemblies (20). The modules (26) can be interlocked so that each module (26) gains additional shielding from the next adjacent module (26). Hydraulic rams (30) are provided for inserting and removing the canisters (12) from the modules (26).

  5. Gas reservoir evaluation for underbalanced horizontal drilling

    Directory of Open Access Journals (Sweden)

    Li Gao

    2014-01-01

    Full Text Available A set of surface equipment for monitoring the parameters of fluid and pressure while drilling was developed, and mathematical models for gas reservoir seepage and wellbore two-phase flow were established. Based on drilling operation parameters, well structure and monitored parameters, the wellbore pressure and the gas reservoir permeability could be predicted theoretically for underbalanced horizontal drilling. Based on the monitored gas production along the well depth, the gas reservoir type could be identified.

  6. Surgical treatment for paralytic horizontal strabismus

    Directory of Open Access Journals (Sweden)

    Feng Zhou*

    2015-08-01

    Full Text Available AIM: To observe the effect of surgery for paralytic horizontal strabismus and the paralytic horizontal strabismus performed by Jensen procedure with antagonist muscle of paralytic muscle recession and medial or lateral rectus extra large resection/recession.METHODS: Fifteen cases(17 eyeswith complete or nearly complete paralytic horizontal strabismus from January 2005 to August. 2014 in our hospital were assessed retrospectively,7 eyes of 7 cases with treatment group A were performed Jensen procedure combined antagonist muscle of paralytic muscle recession, 10 eyes of 8 cases with treatment group B were performed medial or lateral rectus extra large resection/recession. seventeen eyes of 15 cases with an average of 21±8.71mo follow-up were observed.RESULTS: All 17 eyes of 15 cases after the operation obtained satisfied effects, 16 eyes of 14 cases obtained ideal long-term effect. One eye of a patient with a 6mo follow-up was undercorrected of 30△. We found a varying degree of postoperative improvement in visual function. There was a significant reduction in the strabismus angle for distance and near(t=28.71, Pt=36.21, Pt=17.96, Pt=9.20,PCONCLUSION: Jensen procedure combined antagonist muscle of paralytic muscle recession and medial or lateral rectus extra large resection/recession is a safe and successful method of treatment in complete or nearly complete paralysis horizontal strabismus. Patients achieve orthophoria, improvement of the motor ability, and larger field of binocular single vision for long time.

  7. Sizing stand-alone photovoltaic systems

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available A method of sizing stand-alone photovoltaic systems regarding the reliability to satisfy the load demand, economy of components, and discharge depth exploited by the batteries is presented in this work. Solar radiation data simulated by an appropriate stochastic time series model, and not actual measurements, are used in the sizing procedure. This offers two distinct advantages: (a sizing can be performed even for locations where no actual data exist, (b the influence of the variation of the statistical parameters of solar radiation in sizing can be examined. The method has been applied and tested for several representative locations all over Greece for which monthly daily average values of solar radiation are given by ELOT (Hellenic Organization of Standardization.

  8. Standing variation in spatially growing populations

    Science.gov (United States)

    Fusco, Diana; Gralka, Matti; Kayser, Jona; Hallatschek, Oskar

    Patterns of genetic diversity not only reflect the evolutionary history of a species but they can also determine the evolutionary response to environmental change. For instance, the standing genetic diversity of a microbial population can be key to rescue in the face of an antibiotic attack. While genetic diversity is in general shaped by both demography and evolution, very little is understood when both factors matter, as e.g. for biofilms with pronounced spatial organization. Here, we quantitatively explore patterns of genetic diversity by using microbial colonies and well-mixed test tube populations as antipodal model systems with extreme and very little spatial structure, respectively. We find that Eden model simulations and KPZ theory can remarkably reproduce the genetic diversity in microbial colonies obtained via population sequencing. The excellent agreement allows to draw conclusions on the resilience of spatially-organized populations and to uncover new strategies to contain antibiotic resistance.

  9. Energy Expenditure of Standing Compared to Sitting While Conducting Office Tasks.

    Science.gov (United States)

    Burns, Jill; Forde, Cuisle; Dockrell, Sara

    2017-11-01

    Objectives This study aimed to investigate the energy expenditure of common office-based tasks. The objectives were to: (a) test the classification of tasks as sedentary or light-intensity physical activity and (b) compare the energy expenditure of tasks under two postural conditions (sitting and standing). Background The sedentary nature of office work has been highlighted as a health risk, and strategies to reduce sedentary behavior at work have been developed. However, there is limited evidence to guide the utilization of sit-stand workstations in the workplace for metabolic health benefits. Method A repeated measures laboratory-based study compared the energy expenditure of common office tasks in sitting and standing using indirect calorimetry ( n = 22). Four standardized tasks (sitting/standing quietly, reading, typing, sorting paper) under two postural conditions (sitting, standing) were performed in a randomized order. Results The mean energy expenditure for all tasks in sitting and standing was energy expenditure of doing the same task in sitting compared to standing. In a repeated measures ANOVA, task ( p energy expenditure of tasks carried out in sitting compared to standing is negligible. Application The ubiquitous use and utility of sit-stand workstations in the workplace needs to be reviewed. Notwithstanding the potential benefits of movement that may occur naturally, this study confirmed that standing as opposed to sitting does not produce a clinically important increase in energy expenditure.

  10. A Standing-Wave Experiment with a Guitar

    Science.gov (United States)

    Inman, Fred W.

    2006-10-01

    When teaching standing waves, one often uses as examples musical instruments with strings, e.g., pianos, violins, and guitars. In today's popular music culture, young people may be more familiar with guitars than any other string instrument. I was helping my 15-year-old granddaughter make some repairs and adjustments to her electric guitar, and the subject of the spacing between the frets on the fingerboard was raised. I told her that the physics of standing waves and the equal tempered musical scale dictate the location of the frets. The purpose of this paper is to suggest that students might be introduced to the physics of standing waves using a guitar and to the formula for the fret locations. By measuring the positions of the frets, this formula can be tested.

  11. Vertical and horizontal seismometric observations of tides

    Science.gov (United States)

    Lambotte, S.; Rivera, L.; Hinderer, J.

    2006-01-01

    Tidal signals have been largely studied with gravimeters, strainmeters and tiltmeters, but can also be retrieved from digital records of the output of long-period seismometers, such as STS-1, particularly if they are properly isolated. Horizontal components are often noisier than the vertical ones, due to sensitivity to tilt at long periods. Hence, horizontal components are often disturbed by local effects such as topography, geology and cavity effects, which imply a strain-tilt coupling. We use series of data (duration larger than 1 month) from several permanent broadband seismological stations to examine these disturbances. We search a minimal set of observable signals (tilts, horizontal and vertical displacements, strains, gravity) necessary to reconstruct the seismological record. Such analysis gives a set of coefficients (per component for each studied station), which are stable over years and then can be used systematically to correct data from these disturbances without needing heavy numerical computation. A special attention is devoted to ocean loading for stations close to oceans (e.g. Matsushiro station in Japon (MAJO)), and to pressure correction when barometric data are available. Interesting observations are made for vertical seismometric components; in particular, we found a pressure admittance between pressure and data 10 times larger than for gravimeters for periods larger than 1 day, while this admittance reaches the usual value of -3.5 nm/s 2/mbar for periods below 3 h. This observation may be due to instrumental noise, but the exact mechanism is not yet understood.

  12. Portable top drive cuts horizontal drilling costs

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, B. [Saskoil, Regina, Saskatchewan (Canada); Yager, D. [Tesco Drilling Tech., Calgary, Alberta (Canada)

    1993-11-01

    Economic analysis of a seven-well, long-reach horizontal drilling program into an unconsolidated, heavy-oil-bearing reservoir in Winter field near the Alberta/Saskatchewan border in Canada reveals that -- in the right application -- renting a portable top drive drilling system can reduce total drilling costs. Use of the portable top drive combined with other cost-saving measures enabled Saskoil, one of Canada`s larger independents, to drill more cheaply, on a cost-per-meter basis, in 1993 than in 1992. This was despite significant rental rates for drilling rigs and directional drilling services caused by increased demand in Western Canada. Total cost savings of 10% on wells that would otherwise cost in the (C) $500,000 range are believed realistic. Based on this year`s performance, Saskoil recommends top drive for the company`s future horizontal wells in this area. This article describes the operator`s horizontal well program, advantages of top drive in that program and how it was installed and applied. Estimated time savings for six wells, plus other ways top drive can cut costs and improve operations are discussed.

  13. The horizontal plane appearances of scoliosis

    DEFF Research Database (Denmark)

    Illés, Tamás S.; Burkus, Máté; Somoskeőy, Szabolcs

    2017-01-01

    Purpose: A posterior-anterior vertebral vector is proposed to facilitate visualization and understanding of scoliosis. The aim of this study was to highlight the interest of using vertebral vectors, especially in the horizontal plane, in clinical practice. Methods: We used an EOS two-/three-dimen......Purpose: A posterior-anterior vertebral vector is proposed to facilitate visualization and understanding of scoliosis. The aim of this study was to highlight the interest of using vertebral vectors, especially in the horizontal plane, in clinical practice. Methods: We used an EOS two...... cases of a normal spine and a thoracic scoliosis are presented. Results: For a normal spine, vector projections in the transverse plane are aligned with the posterior-anterior anatomical axis. For a scoliotic spine, vector projections in the horizontal plane provide information on the lateral...... of scoliosis. The approach used is simple. These results are sufficient for a first visual analysis furnishing significant clinical information in all three anatomical planes. This visualization represents a reasonable compromise between mathematical purity and practical use....

  14. Construction of preheaters with horizontal tubes

    Energy Technology Data Exchange (ETDEWEB)

    Goetze

    1944-09-27

    This report involved construction of preheaters for distillation and cracking plants in the oil industry, particularly in America. The use of heat transmission by radiation was also a consideration here. The recycling of waste gases occurred, but was not the rule. A convection section was often built next to the radiation section, in which the discharge gases were used for heating the incoming product. The general arrangement of the preheaters was discussed. The first form was a rectangular box with fireproof lining with tubes arranged in a single row along the outer walls and sometimes in a double row on the ceiling. It consisted of smooth and finned tubes. From the simple form a double preheater was developed that allowed one or two common discharge flues to provide as large a heating surface as possible within a reasonable space. Other items discussed were recycling of waste gases, reasons for the choice of horizontal preheaters with radiation heating, the use of vertical tubes in the U.S.A. and elsewhere in the oil industry, details of horizontal preheater tubes, end closures, material, suspension, protection against overloading by radiation, circulation heating, burners, use of horizontal radiation preheaters in hydrogenation in the U.S.A., rebuilding I. G. preheaters, construction, tube supports, and masonry. A list of references on cracking, preheaters, heat transmission, and alloyed steels was given.

  15. Thinning in artificially regenerated young beech stands

    Directory of Open Access Journals (Sweden)

    Novák Jiří

    2015-12-01

    Full Text Available Although beech stands are usually regenerated naturally, an area of up to 5,000 ha year−1 is artificially regenerated by beech in the Czech Republic annually. Unfortunately, these stands often showed insufficient stand density and, consequently, lower quality of stems. Therefore, thinning methods developed for naturally regenerated beech stands are applicable with difficulties. The paper evaluates the data from two thinning experiments established in young artificially regenerated beech stands located in different growing conditions. In both experiments, thinning resulted in the lower amount of salvage cut in following years. Positive effect of thinning on periodic stand basal area increment and on periodic diameter increment of dominant trees was found in the beech stand located at middle elevations. On the other hand, thinning effects in mountain conditions were negligible. Thinning focusing on future stand quality cannot be commonly applied in artificially regenerated beech stands because of their worse initial quality and lower density. However, these stands show good growth and response to thinning, hence their management can be focused on maximising beech wood production.

  16. Design of a thrust stand for high power electric propulsion devices

    Science.gov (United States)

    Haag, Thomas W.

    1989-01-01

    A thrust stand for use with high power electric propulsion devices has been designed and tested. The thrust stand was specifically tailored to the needs of a 0.1 to 0.25 MW magnetoplasmadynamic (MPD) thruster program currently in progress at the NASA Lewis Research Center. The thrust stand structure was built as an inverted pendulum arrangement, supported at the base by water-cooled electrical power flexures. Thrust stand tares due to thruster discharge current were demonstrated to be negligible. Tares due to an applied field magnet current, after considerable effort, were reduced to less than 3.0 percent of measured thrust. These tares, however, could be determined independently and subtracted from the indicated thrust measurement. The paper gives a detailed description of the thrust stand design and operation with a 0.1 MW class MPD device. Other thrust stand tares due to vibration and thermal effects are discussed, along with issues of accuracy and repeatability.

  17. Factors Influencing the Thermal Efficiency of Horizontal Ground Heat Exchangers

    Directory of Open Access Journals (Sweden)

    Eloisa Di Sipio

    2017-11-01

    Full Text Available The performance of very shallow geothermal systems (VSGs, interesting the first 2 m of depth from ground level, is strongly correlated to the kind of sediment locally available. These systems are attractive due to their low installation costs, less legal constraints, easy maintenance and possibility for technical improvements. The Improving Thermal Efficiency of horizontal ground heat exchangers Project (ITER aims to understand how to enhance the heat transfer of the sediments surrounding the pipes and to depict the VSGs behavior in extreme thermal situations. In this regard, five helices were installed horizontally surrounded by five different backfilling materials under the same climatic conditions and tested under different operation modes. The field test monitoring concerned: (a monthly measurement of thermal conductivity and moisture content on surface; (b continuous recording of air and ground temperature (inside and outside each helix; (c continuous climatological and ground volumetric water content (VWC data acquisition. The interactions between soils, VSGs, environment and climate are presented here, focusing on the differences and similarities between the behavior of the helix and surrounding material, especially when the heat pump is running in heating mode for a very long time, forcing the ground temperature to drop below 0 °C.

  18. An experimental study on the resistance and movement of short pile installed in sands under horizontal pullout load

    Directory of Open Access Journals (Sweden)

    Oh Kyun Kwon

    2014-03-01

    Full Text Available In this study, the model tests were conducted on the short piles installed in sands under a horizontal pullout load to investigate their behavior characteristics. From the horizontal loading tests where dimensions of the pile diameter and length, and loading point were varied, the horizontal pullout resistance and the rotational and translational movement pattern of the pile were investigated. As a result, the horizontal pullout resistance of the pile embedded in sands was dependent on the pile length, diameter, loading point, etc. The ultimate horizontal pullout load tended to increase as the loading point (h/L moved to the bottom from the top of the pile, regardless of the ratio between the pile length and diameter (L/D, reached the maximum value at the point of h/L = 0.75, and decreased afterwards. When the horizontal pullout load acted on the upper part above the middle of the pile, the pile rotated clockwise and moved to the pullout direction, and the pivot point of the pile was located at 150–360mm depth below the ground surface. On the other hand, when the horizontal pullout load acted on the lower part of the pile, the pile rotated counterclockwise and travelled horizontally, and the rotational angle was very small.

  19. Hospital staff registered nurses' perception of horizontal violence, peer relationships, and the quality and safety of patient care.

    Science.gov (United States)

    Purpora, Christina; Blegen, Mary A; Stotts, Nancy A

    2015-01-01

    To test hypotheses from a horizontal violence and quality and safety of patient care model: horizontal violence (negative behavior among peers) is inversely related to peer relations, quality of care and it is positively related to errors and adverse events. Additionally, the association between horizontal violence, peer relations, quality of care, errors and adverse events, and nurse and work characteristics were determined. A random sample (n= 175) of hospital staff Registered Nurses working in California. Nurses participated via survey. Bivariate and multivariate analyses tested the study hypotheses. Hypotheses were supported. Horizontal violence was inversely related to peer relations and quality of care, and positively related to errors and adverse events. Including peer relations in the analyses altered the relationship between horizontal violence and quality of care but not between horizontal violence, errors and adverse events. Nurse and hospital characteristics were not related to other variables. Clinical area contributed significantly in predicting the quality of care, errors and adverse events but not peer relationships. Horizontal violence affects peer relationships and the quality and safety of patient care as perceived by participating nurses. Supportive peer relationships are important to mitigate the impact of horizontal violence on quality of care.

  20. Thinning results from a mixed upland hardwood stand after 35 years

    Science.gov (United States)

    Ronald J., Jr. Myers; Kenneth R. Roeder; W. Henry McNab

    2008-01-01

    A long-term study of precommercial thinning was installed in a 6-year-old oak-dominated stand regenerated by clearcutting in the southern Appalachian Mountains of North Carolina. Three levels of residual stand density were tested: control (no thinning), and 200, and 400 residual trees per acre (TPA). Objectives of the study were to determine the response of an upland...

  1. Simulating stand climate, phenology, and photosynthesis of a forest stand with a process-based growth model.

    Science.gov (United States)

    Rötzer, Thomas; Leuchner, Michael; Nunn, Angela J

    2010-07-01

    In the face of climate change and accompanying risks, forest management in Europe is becoming increasingly important. Model simulations can help to understand the reactions and feedbacks of a changing environment on tree growth. In order to simulate forest growth based on future climate change scenarios, we tested the basic processes underlying the growth model BALANCE, simulating stand climate (air temperature, photosynthetically active radiation (PAR) and precipitation), tree phenology, and photosynthesis. A mixed stand of 53- to 60-year-old Norway spruce (Picea abies) and European beech (Fagus sylvatica) in Southern Germany was used as a reference. The results show that BALANCE is able to realistically simulate air temperature gradients in a forest stand using air temperature measurements above the canopy and PAR regimes at different heights for single trees inside the canopy. Interception as a central variable for water balance of a forest stand was also estimated. Tree phenology, i.e. bud burst and leaf coloring, could be reproduced convincingly. Simulated photosynthesis rates were in accordance with measured values for beech both in the sun and the shade crown. For spruce, however, some discrepancies in the rates were obvious, probably due to changed environmental conditions after bud break. Overall, BALANCE has shown to respond to scenario simulations of a changing environment (e.g., climate change, change of forest stand structure).

  2. Modulation of wave-current interactions by horizontal mixing and spatial resolution

    Science.gov (United States)

    Bennis, A.-C.; Dumas, F.; Blanke, B.

    2016-03-01

    The mechanics of rip currents are complex, involving interactions between waves, currents, water levels and bathymetry that pose particular challenges for numerical modeling. Horizontal turbulent diffusion in a rip system is difficult to measure using dye dilution or surfzone drifters, as shown by the range of published values for the horizontal diffusion coefficient. Here, we studied the effects of horizontal mixing on wave-current interactions by testing several diffusivity estimates in a fully coupled 3D wave-current model run at two different spatial resolutions. Published results using very low diffusion have found that near the shore the wave rays converge towards the rip channel because of refraction by the currents. We showed that this process is modulated by both horizontal mixing and spatial resolution. We found that, without the feedback of currents on waves, the flow is more sensitive to horizontal mixing, with large alterations, especially offshore, and generally lower velocities. These modifications ascribed to mixing are similar to those induced by the feedback mechanism. When a large mixing coefficient is used: (i) the behavior of the rip system is similar for both coupling modes (i.e., with and without the feedback of currents on waves) and for each resolution; and (ii) the evolution of the flow is more stable over time. Lastly, we show that the horizontal mixing strongly decreases the intensity of the 3D rip velocity, but not its vertical shear, which is mainly dependent on the vertical mixing scheme and on the forcing terms.

  3. Sprint acceleration mechanics: the major role of hamstrings in horizontal force production

    Directory of Open Access Journals (Sweden)

    Jean-Benoit eMORIN

    2015-12-01

    Full Text Available Recent literature supports the importance of horizontal ground reaction force (GRF production for sprint acceleration performance. Modeling and clinical studies have shown that the hip extensors are very likely contributors to sprint acceleration performance. We experimentally tested the role of the hip extensors in horizontal GRF production during short, maximal, treadmill sprint accelerations. Torque capabilities of the knee and hip extensors and flexors were assessed using an isokinetic dynamometer in 14 males familiar with sprint running. Then, during 6-s sprints on an instrumented motorized treadmill, horizontal and vertical GRF were synchronized with electromyographic (EMG activity of the vastus lateralis, rectus femoris, biceps femoris and gluteus maximus averaged over the first half of support, entire support, entire swing and end-of-swing phases. No significant correlations were found between isokinetic or EMG variables and horizontal GRF. Multiple linear regression analysis showed a significant relationship (P = 0.024 between horizontal GRF and the combination of biceps femoris EMG activity during the end of the swing and the knee flexors eccentric peak torque. In conclusion, subjects who produced the greatest amount of horizontal force were both able to highly activate their hamstring muscles just before ground contact and present high eccentric hamstring peak torque capability.

  4. The Potential for Horizontal Gene Transfer in Sea Ice

    Science.gov (United States)

    Collins, R. E.; Deming, J. W.

    2010-04-01

    Sea ice is a potential hotspot for horizontal gene transfer due to physical concentration of bacteria, viruses, and extracellular DNA. An ice-affiliated bacterium, "Colwellia psychrerythraea," has acquired genes for compatible solute degradation via horizontal gene transfer.

  5. Genetics Home Reference: horizontal gaze palsy with progressive scoliosis

    Science.gov (United States)

    ... Health Conditions HGPPS Horizontal gaze palsy with progressive scoliosis Printable PDF Open All Close All Enable Javascript ... collapse boxes. Description Horizontal gaze palsy with progressive scoliosis ( HGPPS ) is a disorder that affects vision and ...

  6. Extraction of forest stand parameters from CARABAS VHF SAR images

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Fredrik [Swedish Univ. of Agricultural Sciences, Uppsala (Sweden). Centre for Image Analysis

    1999-10-01

    Methods for extracting stand-wise forest parameters from CARABAS VHF SAR images have been developed and evaluated. CARABAS is a unique airborne synthetic aperture radar (SAR), developed by the Swedish Defence Research Establishment. It differs a lot from ordinary microwave radars by using wavelengths between 3.3 and 15 m, making the image intensity highly correlated to stem volume. Furthermore, by providing its own illumination source, the sensor operates independently of daylight and weather conditions. Empirical regression models have been developed for relating backscattering amplitude to stem volume, stem diameter, and tree height. To make comparison between CARABAS image data and forest parameters effective, a fully automatic geo-coding algorithm was developed. Image texture features have also been investigated. By using the variogram as a discriminating feature, CARABAS images and aerial images were segmented into homogeneous regions. Furthermore, a method for discriminating recently clear felled areas from forested areas, combining information from Almaz-1 SAR images and SPOT panchromatic data has also been developed, serving as a comparison to the main work of this thesis. For forest stands at near-horizontal ground, the results for estimating stem volume, stem diameter, and tree height from CARABAS image data are very satisfactory. The root mean square errors for the estimates are comparable to subjective ground-based inventories for dense forest stands. The methods and algorithms described in this thesis have been developed towards an operational remote sensing tool. Altogether, significant potential for mapping of forest characteristics exists using the CARABAS VHF SAR sensor 57 refs, 14 figs, 7 tabs

  7. Cuttings Transport Models and Experimental Visualization of Underbalanced Horizontal Drilling

    OpenAIRE

    Na Wei; YingFeng Meng; Gao Li; LiPing Wan; ZhaoYang Xu; XiaoFeng Xu; YuRui Zhang

    2013-01-01

    Aerated underbalanced horizontal drilling technology has become the focus of the drilling industry at home and abroad, and one of the engineering core issues is the horizontal borehole cleaning. Therefore, calculating the minimum injection volume of gas and liquid accurately is essential for the construction in aerated underbalanced horizontal drilling. This paper establishes a physical model of carrying cuttings and borehole cleaning in wellbore of horizontal well and a critical transport ma...

  8. Geophysical investigations in deep horizontal holes drilled ahead of tunnelling

    Science.gov (United States)

    Carroll, R.D.; Cunningham, M.J.

    1980-01-01

    Deep horizontal drill holes have been used since 1967 by the Defense Nuclear Agency as a primary exploration tool for siting nuclear events in tunnels at the Nevada Test Site. The U.S. Geological Survey had developed geophysical logging techniques for obtaining resistivity and velocity in these holes, and to date 33 horizontal drill holes in excess of 300 m in depth have been successfully logged. The deepest hole was drilled to a horizontal depth of 1125 m. The purposes of the logging measurements are to define clay zones, because of the unstable ground conditions such zones can present to tunnelling, and to define zones of partially saturated rock, because of the attenuating effects such zones have on the shock wave generated by the nuclear detonation. Excessive attenuation is undesirable because the shock wave is used as a tunnel closure mechanism to contain debris and other undesirable explosion products. Measurements are made by pumping resistivity, sonic and geophone probes down the drill string and out of the bit into the open hole. Clay zones are defined by the electrical resistivity technique based on empirical data relating the magnitude of the resistivity measurement to qualitative clay content. Rock exhibiting resistivity of less than 20 ??-m is considered potentially unstable, and resistivities less than 10 ??-m indicate appreciable amounts of clay are present in the rock. Partially saturated rock zones are defined by the measurement of the rock sound speed. Zones in the rock which exhibit velocities less than 2450 m/sec are considered of potential concern. ?? 1980.

  9. Horizontal gene transfer among genomes: The complexity hypothesis

    OpenAIRE

    Jain, Ravi; Rivera, Maria C.; Lake, James A.

    1999-01-01

    Increasingly, studies of genes and genomes are indicating that considerable horizontal transfer has occurred between prokaryotes. Extensive horizontal transfer has occurred for operational genes (those involved in housekeeping), whereas informational genes (those involved in transcription, translation, and related processes) are seldomly horizontally transferred. Through phylogenetic analysis of six complete prokaryotic genomes and the identification of 312 sets of orthologous genes present i...

  10. Procedures for Determining the Performance of Stand-Alone Photovoltaic Systems

    Energy Technology Data Exchange (ETDEWEB)

    McNutt, P.; Kroposki, B.; Hansen, R.; DeBlasio, R. (National Renewable Energy Laboratory); Thomas, M. (Sandia National Laboratories); Durand, S. (Florida Solar Energy Center); Rosenthal, A. (Southwest Technology Development Institute); Hutchinson, P. (Photovoltaics for Utility Scale Applications)

    1999-09-21

    This document provides the procedures for determining the performance of stand-alone PV systems. The procedures in this document provide a common approach for evaluating whether a given PV system is suitable to perform the function for which it was designed and manufactured to accomplish, and whether it will provide adequate power to run the load. These procedures cover small stand-alone PV systems. They cover complete outdoor system testing. Test results are valid only for the system that is tested.

  11. Mr Gary Nairn MP, Chair of the Standing Committee on Science and Innovation, Australia

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    Photos 01,04,06,07: Mr Gary Nairn MP, Chair of the Standing Committee on Science and Innovation, Australia,visiting the silicon test laboratory, April 2003. Photos 02,03: From left to right: Mr Gary Nairn MP, Chair of the Standing Committee on Science and Innovation, Australia,visiting the silicon test laboratory with Prof. Steinar Stapnes, Physicist in the ATLAS experiment, April 2003. Photos 02,09: Mrs Kerrye Nairn, Australia,visiting the silicon test laboratory, April 2003

  12. New airfoils for small horizontal axis wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Giguere, P.; Selig, M.S. [Univ. of Illinois, Urbana, IL (United States)

    1997-12-31

    In a continuing effort to enhance the performance of small energy systems, one root airfoil and three primary airfoils were specifically designed for small horizontal axis wind turbines. These airfoils are intended primarily for 1-10 kW variable-speed wind turbines for both conventional (tapered/twisted) or pultruded blades. The four airfoils were wind-tunnel tested at Reynolds numbers between 100,000 and 500,000. Tests with simulated leading-edge roughness were also conducted. The results indicate that small variable-speed wind turbines should benefit from the use of the new airfoils which provide enhanced lift-to-drag ratio performance as compared with previously existing airfoils.

  13. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  14. Neurotransmitter modulation of extracellular H+ fluxes from isolated retinal horizontal cells of the skate

    Science.gov (United States)

    Molina, Anthony J A; Verzi, Michael P; Birnbaum, Andrea D; Yamoah, Ebenezer N; Hammar, Katherine; Smith, Peter J S; Malchow, Robert Paul

    2004-01-01

    Self-referencing H+-selective microelectrodes were used to measure extracellular H+ fluxes from horizontal cells isolated from the skate retina. A standing H+ flux was detected from quiescent cells, indicating a higher concentration of free hydrogen ions near the extracellular surface of the cell as compared to the surrounding solution. The standing H+ flux was reduced by removal of extracellular sodium or application of 5-(N-ethyl-N-isopropyl) amiloride (EIPA), suggesting activity of a Na+–H+ exchanger. Glutamate decreased H+ flux, lowering the concentration of free hydrogen ions around the cell. AMPA/kainate receptor agonists mimicked the response, and the AMPA/kainate receptor antagonist 6-cyano-7-nitroquinoxaline-2,3-dione (CNQX) eliminated the effects of glutamate and kainate. Metabotropic glutamate agonists were without effect. Glutamate-induced alterations in H+ flux required extracellular calcium, and were abolished when cells were bathed in an alkaline Ringer solution. Increasing intracellular calcium by photolysis of the caged calcium compound NP-EGTA also altered extracellular H+ flux. Immunocytochemical localization of the plasmalemma Ca2+–H+-ATPase (PMCA pump) revealed intense labelling within the outer plexiform layer and on isolated horizontal cells. Our results suggest that glutamate modulation of H+ flux arises from calcium entry into cells with subsequent activation of the plasmalemma Ca2+–H+-ATPase. These neurotransmitter-induced changes in extracellular pH have the potential to play a modulatory role in synaptic processing in the outer retina. However, our findings argue against the hypothesis that hydrogen ions released by horizontal cells normally act as the inhibitory feedback neurotransmitter onto photoreceptor synaptic terminals to create the surround portion of the centre-surround receptive fields of retinal neurones. PMID:15272044

  15. Validation of the Regional Climate Model ALARO with different dynamical downscaling approaches and different horizontal resolutions

    Science.gov (United States)

    Berckmans, Julie; Hamdi, Rafiq; De Troch, Rozemien; Giot, Olivier

    2015-04-01

    At the Royal Meteorological Institute of Belgium (RMI), climate simulations are performed with the regional climate model (RCM) ALARO, a version of the ALADIN model with improved physical parameterizations. In order to obtain high-resolution information of the regional climate, lateral bounary conditions (LBC) are prescribed from the global climate model (GCM) ARPEGE. Dynamical downscaling is commonly done in a continuous long-term simulation, with the initialisation of the model at the start and driven by the regularly updated LBCs of the GCM. Recently, more interest exists in the dynamical downscaling approach of frequent reinitializations of the climate simulations. For these experiments, the model is initialised daily and driven for 24 hours by the GCM. However, the surface is either initialised daily together with the atmosphere or free to evolve continuously. The surface scheme implemented in ALARO is SURFEX, which can be either run in coupled mode or in stand-alone mode. The regional climate is simulated on different domains, on a 20km horizontal resolution over Western-Europe and a 4km horizontal resolution over Belgium. Besides, SURFEX allows to perform a stand-alone or offline simulation on 1km horizontal resolution over Belgium. This research is in the framework of the project MASC: "Modelling and Assessing Surface Change Impacts on Belgian and Western European Climate", a 4-year project funded by the Belgian Federal Government. The overall aim of the project is to study the feedbacks between climate changes and land surface changes in order to improve regional climate model projections at the decennial scale over Belgium and Western Europe and thus to provide better climate projections and climate change evaluation tools to policy makers, stakeholders and the scientific community.

  16. An Experimental Study of Oil / Water Flow in Horizontal Pipes

    Energy Technology Data Exchange (ETDEWEB)

    Elseth, Geir

    2001-07-01

    The purpose of this thesis is to study the behaviour of the simultaneous flow of oil and water in horizontal pipes. In this connection, two test facilities are used. Both facilities have horizontal test sections with inner pipe diameters equal to 2 inches. The largest facility, called the model oil facility, has reservoirs of 1 m{sub 3} of each medium enabling flow rates as high as 30 m{sub 3}/h, which corresponds to mixture velocities as high as 3.35 m/s. The flow rates of oil and water can be varied individually producing different flow patterns according to variations in mixture velocity and input water cut. Two main classes of flows are seen, stratified and dispersed. In this facility, the main focus has been on stratified flows. Pressure drops and local phase fractions are measured for a large number of flow conditions. Among the instruments used are differential pressure transmitters and a traversing gamma densitometer, respectively. The flow patterns that appear are classified in flow pattern maps as functions of either mixture velocity and water cut or superficial velocities. From these experiments a smaller number of stratified flows are selected for studies of velocity and turbulence. A laser Doppler anemometer (LDA) is applied for these measurements in a transparent part of the test section. To be able to produce accurate measurements a partial refractive index matching procedure is used. The other facility, called the matched refractive index facility, has a 0.2 m{sub 3} reservoir enabling mainly dispersed flows. Mixture velocities range from 0.75 m/s to 3 m/s. The fluids in this facility are carefully selected to match the refractive index of the transparent part of the test section. A full refractive index matching procedure is carried out producing excellent optical conditions for velocity and turbulence studies by LDA. In addition, pressure drops and local phase fractions are measured. (author)

  17. Search for horizontal bosons at the SSC

    Energy Technology Data Exchange (ETDEWEB)

    Albright, C.H.; Deshpande, N.G.; Gunion, J.F.; Haber, H.E.

    1984-01-01

    The production process anti p p ..-->.. l/sup -/l'/sup +/ + X, where the leptons belong to two different generations and X refers to spectator jets, provides a clear signature for horizontal (generation-changing) bosons when the leptons are emitted nearly back-to-back and p/sub T//sup miss/ = 0. Cross sections and p/sub T/ distributions for each lepton are presented, and discovery limits on M/sub H/ are extracted for several different channels.

  18. Feedback from luminosity horizontal cells mediates depolarizing responses of chromaticity horizontal cells in the Xenopus retina.

    OpenAIRE

    Witkovsky, P; Gabriel, R; Krizaj, D; Akopian, A.

    1995-01-01

    It has been proposed that the depolarizing responses of chromaticity horizontal cells (C-HCs) to red light depend on a feedback signal from luminosity horizontal cells (L-HCs) to short-wavelength-sensitive cones in the retinas of lower vertebrates. In this regard we studied the C-HCs of the Xenopus retina. C-HCs and L-HCs were identified by physiological criteria and then injected with neurobiotin. The retina then was incubated with peanut agglutinin, which stains red-but not blue-sensitive c...

  19. Intraradicular Splinting with Endodontic Instrument of Horizontal Root Fracture

    Directory of Open Access Journals (Sweden)

    Ersan Çiçek

    2015-01-01

    Full Text Available Introduction. Root fractures, defined as fractures involving dentine, cementum, and pulpal and supportive tissues, constitute only 0.5–7% of all dental injuries. Horizontal root fractures are commonly observed in the maxillary anterior region and 75% of these fractures occur in the maxillary central incisors. Methods. A 14-year-old female patient was referred to our clinic three days after a traffic accident. In radiographic examination, the right maxillary central incisor was fractured horizontally in apical thirds. Initially, following local infiltrative anesthetics, the coronal fragment was repositioned and this was radiographically confirmed. Then the stabilization splint was applied and remained for three months. After three weeks, according to the results of the vitality tests, the right and left central incisors were nonvital. For the right central incisor, both the coronal and apical fragments were involved in the endodontic preparation. Results. For the right central tooth, both the coronal and apical root fragments were endodontically treated and obturated at a single visit with white mineral trioxide aggregate whilst the fragments were stabilized internally by insertion of a size 40 Hedstrom stainless-steel endodontic file into the canal. Conclusion. Four-year follow-up examination revealed satisfactory clinical and radiographic findings with hard tissue repair of the fracture line.

  20. Improved gene tree error correction in the presence of horizontal gene transfer.

    Science.gov (United States)

    Bansal, Mukul S; Wu, Yi-Chieh; Alm, Eric J; Kellis, Manolis

    2015-04-15

    The accurate inference of gene trees is a necessary step in many evolutionary studies. Although the problem of accurate gene tree inference has received considerable attention, most existing methods are only applicable to gene families unaffected by horizontal gene transfer. As a result, the accurate inference of gene trees affected by horizontal gene transfer remains a largely unaddressed problem. In this study, we introduce a new and highly effective method for gene tree error correction in the presence of horizontal gene transfer. Our method efficiently models horizontal gene transfers, gene duplications and losses, and uses a statistical hypothesis testing framework [Shimodaira-Hasegawa (SH) test] to balance sequence likelihood with topological information from a known species tree. Using a thorough simulation study, we show that existing phylogenetic methods yield inaccurate gene trees when applied to horizontally transferred gene families and that our method dramatically improves gene tree accuracy. We apply our method to a dataset of 11 cyanobacterial species and demonstrate the large impact of gene tree accuracy on downstream evolutionary analyses. An implementation of our method is available at http://compbio.mit.edu/treefix-dtl/ : mukul@engr.uconn.edu or manoli@mit.edu Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press.

  1. Benchmarking the Collocation Stand-Alone Library and Toolkit (CSALT)

    Science.gov (United States)

    Hughes, Steven; Knittel, Jeremy; Shoan, Wendy; Kim, Youngkwang; Conway, Claire; Conway, Darrel J.

    2017-01-01

    This paper describes the processes and results of Verification and Validation (VV) efforts for the Collocation Stand Alone Library and Toolkit (CSALT). We describe the test program and environments, the tools used for independent test data, and comparison results. The VV effort employs classical problems with known analytic solutions, solutions from other available software tools, and comparisons to benchmarking data available in the public literature. Presenting all test results are beyond the scope of a single paper. Here we present high-level test results for a broad range of problems, and detailed comparisons for selected problems.

  2. Inverted Pendulum Standing Apparatus for Investigating Closed-Loop Control of Ankle Joint Muscle Contractions during Functional Electrical Stimulation

    OpenAIRE

    Tan, John F.; Masani, Kei; Vette, Albert H.; Zariffa, José; Robinson, Mark; Lynch, Cheryl; Popovic, Milos R.

    2014-01-01

    The restoration of arm-free standing in individuals with paraplegia can be facilitated via functional electrical stimulation (FES). In developing adequate control strategies for FES systems, it remains challenging to test the performance of a particular control scheme on human subjects. In this study, we propose a testing platform for developing effective control strategies for a closed-loop FES system for standing. The Inverted Pendulum Standing Apparatus (IPSA) is a mechanical inverted pend...

  3. Reineke’s stand density index: a quantitative and non-unitless measure of stand density

    Science.gov (United States)

    Curtis L. VanderSchaaf

    2013-01-01

    When used as a measure of relative density, Reineke’s stand density index (SDI) can be made unitless by relating the current SDI to a standard density but when used as a quantitative measure of stand density SDI is not unitless. Reineke’s SDI relates the current stand density to an equivalent number of trees per unit area in a stand with a quadratic mean diameter (Dq)...

  4. Applying GPS to check horizontal control quality

    Directory of Open Access Journals (Sweden)

    Jakub Vincent

    2004-03-01

    Full Text Available GPS technologies can also be used for check quality in available horizontal point set with coordinates CJ of the frame S-JTSK. When survey and setting-out tasks should be performed in certain area, one can found in it allways some points of the fundamental and detail state controls. To use these points for some actual aims, it is necessary to investigate their compatibility (among the point mark positions and the point coordinate of control points. This can be done using GPS surveying that may be at the same time employed to determine the new point in the relevant area.Principle of quality investigatingf an existing control is founded on determination of point coordinates CJt from GPS measurements. Then, based on discrepancies among the "official" netpoint coordinates CJ and coordinates CJt "given by GPS", it can be estimated the degree and the real compatibility dislocations in the network structure of the existing points.Realisation procedure for the introduced investigation is demonstrated on GPS checking (by SOKKIA STRATUS receivers horizontal control for reconstruction of a railway bridge on river Bodrog in East Slovakia.It can be shown from the results in Table 3, that points P3 and P7 are useless due to their incompatibility (inconsistency in the inspected point set. For other 7 points (Table 7 the average measure of incompatibility reads 9.8 mm that make possible applying these points for precise setting-out

  5. Development of a stand density index equation for slash pine stands

    Science.gov (United States)

    Paul F. Doruska

    2002-01-01

    Stand density index (SDI) is commonly used as the basis for density management guides for even-aged forest stands. Many tree species follow the same self-thinning trajectory, allowing for the use of stand density index in such guides. Slash pine (Pinus elliottii Englem.) has been shown to depart from the self-thinning trajectory exhibited by other...

  6. SPEED ROLLER STAND MEASUREMENT SYSTEM CHECKING TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Y. Zybtsev

    2011-01-01

    Full Text Available The study has shown that the accuracy of brakes checking by inertial stands depends upon the applied methods of measurement of braking parameters (stand slowing down, braking distance, brakes triggering time, current speed as well as the methods of metrological checking of measuring system canals.

  7. Design Difficulties in Stand Density Studies

    Science.gov (United States)

    Frank A. Bennett

    1969-01-01

    Designing unbiased stand density studies is difficult. An acceptable sample requires stratification of the plots of age, site, and density. When basal area, percent stocking, or Reineke's stand density index is used as the density measure, this stratification forces a high negative correlation between site and number of trees per acre. Mortality in trees per acre...

  8. NUMERICAL DETERMINATION OF HORIZONTAL SETTLERS PERFORMANCE

    Directory of Open Access Journals (Sweden)

    M. M. Biliaiev

    2015-08-01

    Full Text Available Purpose.Horizontal settlers are one of the most important elements in the technological scheme of water purification. Their use is associated with the possibility to pass a sufficiently large volume of water. The important task at the stage of their designing is evaluating of their effectiveness. Calculation of the efficiency of the settler can be made by mathematical modeling. Empirical, analytical models and techniques that are currently used to solve the problem, do not allow to take into account the shape of the sump and various design features that significantly affects the loyalty to a decision on the choice of the size of the settling tank and its design features. The use of analytical models is limited only to one-dimensional solutions, does not allow accounting for nonuniform velocity field of the flow in the settler. The use of advanced turbulence models for the calculation of the hydrodynamics in the settler complex forms now requires very powerful computers. In addition, the calculation of one variant of the settler may last for dozens of hours. The aim of the paper is to build a numerical model to evaluate the effectiveness of horizontal settling tank modified design. Methodology. Numerical models are based on: 1 equation of potential flow; 2 equation of inviscid fluid vortex flow; 3 equation of viscous fluid dynamics; 4 mass transfer equation. For numerical simulation the finite difference schemes are used. The numerical calculation is carried out on a rectangular grid. For the formation of the computational domain markers are used. Findings.The models allow calculating the clarification process in the settler with different form and different configuration of baffles. Originality. A new approach to investigate the mass transfer process in horizontal settler was proposed. This approach is based on the developed CFD models. Three fluid dynamics models were used for the numerical investigation of flows and waste waters purification

  9. Stand pentru încercarea grinzilor precomprimate U 37m

    Directory of Open Access Journals (Sweden)

    Mircea Păstrav

    2011-03-01

    Full Text Available As part of conformity certification process of prefabricated beams used for bridges and viaducts on Transylvania Motorway, a prestressed concrete U-shaped beam of 37.10 m span with superior slab cast in situ was subjected to a resistance test. Due to beam overall dimensions of 3.30 x 2.50 x 37.10 m and to the important forces which have to be applied it has been necessary to build an adequate stand right near the precast site. Paper briefly presents the mechanical, technological, economical and work safety requirements, the design and the actual implementation of the one of the largest testing stands made în our country.

  10. Relationship between vertical and horizontal jump variables and muscular performance in athletes.

    Science.gov (United States)

    Dobbs, Caleb W; Gill, Nicholas D; Smart, Daniel J; McGuigan, Michael R

    2015-03-01

    This study investigated the relationship between vertical and horizontal measures in bilateral and unilateral countermovement jump, drop jump and squat jump (SJ), and sprinting speed and muscle architecture of both the vastus lateralis and gastrocnemius. Subjects (n = 17) completed a 30-m sprint test, muscle stiffness test; ultrasound measures, and a jump testing session. Measures of horizontal peak and mean force, in both bilateral and unilateral jumps, tended to have greater relationships to sprint speeds (R = 0.132-0.576) than peak and mean force in the vertical plane (R = 0.008-0.504). Vertical velocity variables also showed some large and very large correlations to sprint speed (R = 0.062-0.635). Unilateral measures of velocity tended to have larger correlations to sprint performance than their bilateral counterparts across all jump types and peak and mean velocity in SJ showed large and very large correlations to sprint speed (bilateral R = 0.227-0.635; unilateral 0.393-0.574). Few large correlations were shown between muscle stiffness measures of muscle architecture and kinetic and kinematic variables in either vertical or horizontal jumps. The present findings suggest that sport scientists and strength and conditioning practitioners concerned with the prognostic value of kinetic variables to functional movements such as sprint speed should also use horizontal jumps in addition to vertical jumps in testing and training.

  11. Kinetics of carbendazim degradation in a horizontal tubular biofilm reactor.

    Science.gov (United States)

    Alvarado-Gutiérrez, María Luisa; Ruiz-Ordaz, Nora; Galíndez-Mayer, Juvencio; Santoyo-Tepole, Fortunata; Curiel-Quesada, Everardo; García-Mena, Jaime; Ahuatzi-Chacón, Deifilia

    2017-04-01

    The fungicide carbendazim is an ecotoxic agent affecting aquatic biota. Due to its suspected hormone-disrupting effects, it is considered a "priority hazard substance" by the Water Framework Directive of the European Commission, and its degradation is of major concern. In this work, a horizontal tubular biofilm reactor (HTBR) operating in plug-flow regime was used to study the kinetics of carbendazim removal by an acclimated microbial consortium. The reactor was operated in steady state continuous culture at eight different carbendazim loading rates. The concentrations of the fungicide were determined at several distances of the HTBR. At the loading rates tested, the highest instantaneous removal rates were observed in the first section of the tubular biofilm reactor. No evidence of inhibition of the catabolic activity of the microbial community was found. Strains of the genera Flectobacillus, Klebsiella, Stenotrophomonas, and Flavobacterium were identified in the biofilm; the last three degrade carbendazim in axenic culture.

  12. Characterisation of a horizontal axis wind turbine’s tip and root vortices

    OpenAIRE

    Sherry, Michael; Sheridan, John; Lo Jacono, David

    2013-01-01

    The vortical near wake of a model horizontal axis wind turbine has been investigated experimentally in a water channel. The objective of this work is to study vortex interaction and stability of the helical vortex filaments within a horizontal axis wind turbine wake. The experimental model is a geometrically scaled version of the Tjæreborg wind turbine, which existed in western Denmark in the late 1980s. Here, the turbine was tested in both the upwind and downwind configura...

  13. Parametric analysis of synthetic aperture radar data for characterization of deciduous forest stands

    Science.gov (United States)

    Wu, Shih-Tseng

    1987-01-01

    The SAR sensor parameters that affect the estimation of deciduous forest stand characteristics were examined using data sets for the Gulf Coastal Plain region, acquired by the NASA/JPL multipolarization airborne SAR. In the regression analysis, the mean digital-number values of the three polarization data are used as the independent variables to estimate the average tree height (HT), basal area (BA), and total-tree biomass (TBM). The following results were obtained: (1) in the case of simple regression and using 28 plots, vertical-vertical (VV) polarization yielded the largest correlation coefficients (r) in estimating HT, BA, and TBM; (2) in the case of multiple regression, the horizontal-horizontal (HH) and VV polarization combination yielded the largest r value in estimating HT, while the VH and HH polarization combination yielded the largest r values in estimating BA and TBM. With the addition of a third polarization, the increase in r values is insignificant.

  14. Horizontal stresses below two agricultural vehicles

    DEFF Research Database (Denmark)

    Lamande, Mathieu André Maurice; Munkholm, Lars Juhl; Nielsen, Janne Aalborg

    below the edge of tires. Stress distribution at the tire/soil contact is not uniform. Dimensions and inflation pressure are key factors for the ability of agricultural tires to distribute the wheel load. Our hypothesis was that the risk of shearing increases with the tire inflation pressure...... and the number of wheels. We measured horizontal stress at two depths (0.3 and 0.5 m) below tires of two slurry spreaders: one self-propelled machine equipped with wide tires (1.050 m) and low inflation pressure (150 kPa) but carrying a high wheel load (120 kN), and one tractor towing a three-axle slurry...... confounded (wheel load, inflation...

  15. Horizontal Gene Transfer, Dispersal and Haloarchaeal Speciation

    Science.gov (United States)

    Papke, R. Thane; Corral, Paulina; Ram-Mohan, Nikhil; de la Haba, Rafael R.; Sánchez-Porro, Cristina; Makkay, Andrea; Ventosa, Antonio

    2015-01-01

    The Halobacteria are a well-studied archaeal class and numerous investigations are showing how their diversity is distributed amongst genomes and geographic locations. Evidence indicates that recombination between species continuously facilitates the arrival of new genes, and within species, it is frequent enough to spread acquired genes amongst all individuals in the population. To create permanent independent diversity and generate new species, barriers to recombination are probably required. The data support an interpretation that rates of evolution (e.g., horizontal gene transfer and mutation) are faster at creating geographically localized variation than dispersal and invasion are at homogenizing genetic differences between locations. Therefore, we suggest that recurrent episodes of dispersal followed by variable periods of endemism break the homogenizing forces of intrapopulation recombination and that this process might be the principal stimulus leading to divergence and speciation in Halobacteria. PMID:25997110

  16. Horizontal gene exchange in environmental microbiota

    Directory of Open Access Journals (Sweden)

    Rustam I Aminov

    2011-07-01

    Full Text Available Horizontal gene transfer (HGT plays an important role in the evolution of life on the Earth. This view is supported by numerous occasions of HGT that are recorded in the genomes of all three domains of living organisms. HGT-mediated rapid evolution is especially noticeable among the Bacteria, which demonstrate formidable adaptability in the face of recent environmental changes imposed by human activities, such as the use of antibiotics, industrial contamination, and intensive agriculture. At the heart of the HGT-driven bacterial evolution and adaptation are highly sophisticated natural genetic engineering tools in the form of a variety of mobile genetic elements (MGEs. The main aim of this review is to give a brief account of the occurrence and diversity of MGEs in natural ecosystems and of the environmental factors that may affect MGE-mediated HGT.

  17. Modelling the horizontal steam generator with APROS

    Energy Technology Data Exchange (ETDEWEB)

    Ylijoki, J. [VTT Energy, Espoo (Finland); Palsinajaervi, C.; Porkholm, K. [IVO International Ltd, Vantaa (Finland)

    1995-12-31

    In this paper the capability of the five- and six-equation models of the simulation code APROS to simulate the behaviour of the horizontal steam generator is discussed. Different nodalizations are used in the modelling and the results of the stationary state runs are compared. Exactly the same nodalizations have been created for the five- and six-equation models. The main simulation results studied in this paper are void fraction and mass flow distributions in the secondary side of the steam generator. It was found that quite a large number of simulation volumes is required to simulate the distributions with a reasonable accuracy. The simulation results of the different models are presented and their validity is discussed. (orig.). 4 refs.

  18. Horizontal Gene Transfer, Dispersal and Haloarchaeal Speciation

    Directory of Open Access Journals (Sweden)

    R. Thane Papke

    2015-05-01

    Full Text Available The Halobacteria are a well-studied archaeal class and numerous investigations are showing how their diversity is distributed amongst genomes and geographic locations. Evidence indicates that recombination between species continuously facilitates the arrival of new genes, and within species, it is frequent enough to spread acquired genes amongst all individuals in the population. To create permanent independent diversity and generate new species, barriers to recombination are probably required. The data support an interpretation that rates of evolution (e.g., horizontal gene transfer and mutation are faster at creating geographically localized variation than dispersal and invasion are at homogenizing genetic differences between locations. Therefore, we suggest that recurrent episodes of dispersal followed by variable periods of endemism break the homogenizing forces of intrapopulation recombination and that this process might be the principal stimulus leading to divergence and speciation in Halobacteria.

  19. Horizontal gene transfer, dispersal and haloarchaeal speciation.

    Science.gov (United States)

    Papke, R Thane; Corral, Paulina; Ram-Mohan, Nikhil; Haba, Rafael R de la; Sánchez-Porro, Cristina; Makkay, Andrea; Ventosa, Antonio

    2015-05-19

    The Halobacteria are a well-studied archaeal class and numerous investigations are showing how their diversity is distributed amongst genomes and geographic locations. Evidence indicates that recombination between species continuously facilitates the arrival of new genes, and within species, it is frequent enough to spread acquired genes amongst all individuals in the population. To create permanent independent diversity and generate new species, barriers to recombination are probably required. The data support an interpretation that rates of evolution (e.g., horizontal gene transfer and mutation) are faster at creating geographically localized variation than dispersal and invasion are at homogenizing genetic differences between locations. Therefore, we suggest that recurrent episodes of dispersal followed by variable periods of endemism break the homogenizing forces of intrapopulation recombination and that this process might be the principal stimulus leading to divergence and speciation in Halobacteria.

  20. Horizontal gene transfer in eukaryotic plant pathogens.

    Science.gov (United States)

    Soanes, Darren; Richards, Thomas A

    2014-01-01

    Gene transfer has been identified as a prevalent and pervasive phenomenon and an important source of genomic innovation in bacteria. The role of gene transfer in microbial eukaryotes seems to be of a reduced magnitude but in some cases can drive important evolutionary innovations, such as new functions that underpin the colonization of different niches. The aim of this review is to summarize published cases that support the hypothesis that horizontal gene transfer (HGT) has played a role in the evolution of phytopathogenic traits in fungi and oomycetes. Our survey of the literature identifies 46 proposed cases of transfer of genes that have a putative or experimentally demonstrable phytopathogenic function. When considering the life-cycle steps through which a pathogen must progress, the majority of the HGTs identified are associated with invading, degrading, and manipulating the host. Taken together, these data suggest HGT has played a role in shaping how fungi and oomycetes colonize plant hosts.

  1. Mapping Proprioception across a 2D Horizontal Workspace

    Science.gov (United States)

    Wilson, Elizabeth T.; Wong, Jeremy; Gribble, Paul L.

    2010-01-01

    Relatively few studies have been reported that document how proprioception varies across the workspace of the human arm. Here we examined proprioceptive function across a horizontal planar workspace, using a new method that avoids active movement and interactions with other sensory modalities. We systematically mapped both proprioceptive acuity (sensitivity to hand position change) and bias (perceived location of the hand), across a horizontal-plane 2D workspace. Proprioception of both the left and right arms was tested at nine workspace locations and in 2 orthogonal directions (left-right and forwards-backwards). Subjects made repeated judgments about the position of their hand with respect to a remembered proprioceptive reference position, while grasping the handle of a robotic linkage that passively moved their hand to each judgement location. To rule out the possibility that the memory component of the proprioceptive testing procedure may have influenced our results, we repeated the procedure in a second experiment using a persistent visual reference position. Both methods resulted in qualitatively similar findings. Proprioception is not uniform across the workspace. Acuity was greater for limb configurations in which the hand was closer to the body, and was greater in a forward-backward direction than in a left-right direction. A robust difference in proprioceptive bias was observed across both experiments. At all workspace locations, the left hand was perceived to be to the left of its actual position, and the right hand was perceived to be to the right of its actual position. Finally, bias was smaller for hand positions closer to the body. The results of this study provide a systematic map of proprioceptive acuity and bias across the workspace of the limb that may be used to augment computational models of sensory-motor control, and to inform clinical assessment of sensory function in patients with sensory-motor deficits. PMID:20686612

  2. The power of phylogenetic approaches to detect horizontally transferred genes.

    Science.gov (United States)

    Poptsova, Maria S; Gogarten, J Peter

    2007-03-21

    Horizontal gene transfer plays an important role in evolution because it sometimes allows recipient lineages to adapt to new ecological niches. High genes transfer frequencies were inferred for prokaryotic and early eukaryotic evolution. Does horizontal gene transfer also impact phylogenetic reconstruction of the evolutionary history of genomes and organisms? The answer to this question depends at least in part on the actual gene transfer frequencies and on the ability to weed out transferred genes from further analyses. Are the detected transfers mainly false positives, or are they the tip of an iceberg of many transfer events most of which go undetected by current methods? Phylogenetic detection methods appear to be the method of choice to infer gene transfers, especially for ancient transfers and those followed by orthologous replacement. Here we explore how well some of these methods perform using in silico transfers between the terminal branches of a gamma proteobacterial, genome based phylogeny. For the experiments performed here on average the AU test at a 5% significance level detects 90.3% of the transfers and 91% of the exchanges as significant. Using the Robinson-Foulds distance only 57.7% of the exchanges and 60% of the donations were identified as significant. Analyses using bipartition spectra appeared most successful in our test case. The power of detection was on average 97% using a 70% cut-off and 94.2% with 90% cut-off for identifying conflicting bipartitions, while the rate of false positives was below 4.2% and 2.1% for the two cut-offs, respectively. For all methods the detection rates improved when more intervening branches separated donor and recipient. Rates of detected transfers should not be mistaken for the actual transfer rates; most analyses of gene transfers remain anecdotal. The method and significance level to identify potential gene transfer events represent a trade-off between the frequency of erroneous identification (false

  3. A Similitude Theory for Bucket Foundations Under Monotonic Horizontal Load in Dense Sand

    DEFF Research Database (Denmark)

    Foglia, Aligi; Ibsen, Lars Bo

    2013-01-01

    of bucket foundations under horizontal load, is put forward. A constitutive law of the soil and a load-displacement relationship for the bucket foundation are theoretically obtained. Triaxial tests of sand, and small-scale tests of bucket foundation, are respectively employed to corroborate the theory....... Attention is given to the different behaviour shown during the compressive and dilative phases of the soil. Some analogy between triaxial tests and tests of bucket foundation are pointed out. A theoretically derived power law is found capable to represent the dimensionless horizontal load......-displacement curves of experimental results. In accordance with the theory, the exponent of the power law slightly varies between tests with considerably different features. The non-dimensional moment-rotation relationship is represented by a power law as well. The approach is considered valid for fatigue design...

  4. Horizontal pull-out strength of orthodontic infrazygomatic mini-implant: an in vitro study.

    Science.gov (United States)

    Chen, Chun-Ming; Wu, Ju-Hui; Lu, Pei-Chen; Wang, Huang-Chi; Lee, Huey-Er; Wang, Chau-Hsiang; Du, Je-Kang

    2011-04-01

    New modified mini-implants have recently come into use for reinforcing skeletal anchorage in orthodontic application. The aim of this study was to investigate the influence of the design of a mini-implant on its mechanical strength. We measured the insertion torques and horizontal pull-out strengths of 3 brands of infrazygomatic mini-implants (AbsoAnchor, Bioray, and Lomas; 2 mm for all). Five implants of each brand were manually driven 6 mm into the artificial bone. Significant differences in various parameters among the brands were investigated with the Kruskal-Wallis test. There was no significant relationship between insertion torque and horizontal pull-out strength. The Bioray mini-implants had significantly greater horizontal pull-out strength than the AbsoAnchor mini-implants. The design of the mini-implant can influence its insertion torque and horizontal pull-out strength. In our findings, the horizontal pull-out strength of all mini-implants placed in the infrazygomatic crest was significantly greater than the orthodontic force applied.

  5. The five-times-sit-to-stand-test (FTSST), the short version of the activities-specific balance confidence (ABC) scale, and fear of falling predict step execution time (SET) in older adults.

    Science.gov (United States)

    Goldberg, Allon

    2012-01-01

    Rapid stepping is a common strategy employed by older adults to avoid falls. The relative contributions of dynamic balance, balance confidence and fear of falling to SET, was investigated in older adults. Thirty-three community-dwelling older adults completed tests of SET as well as the FTSST, a test of motor performance associated with dynamic balance. Psychological indicators of balance-related confidence assessed were the ABC 6-item scale (ABC-6) and fear of falling. Mean SET was significantly slower in the fear of falling group than in the no fear of falling group (p<0.001). Correlational analysis indicated that poorer performance on the FTSST and lower balance confidence, were associated with slower time to execute a rapid step. A stepwise multiple regression model including the FTSST, ABC-6 score, and fear of falling as predictor variables, explained 58% of the variance in SET (p<0.001). The FTSST explained the largest proportion of the variance in SET (36%), followed by fear of falling (15%) and ABC-6 score (7%). These data show that the FTSST, ABC-6 score and fear of falling are significant and independent predictors of SET in older adults. Dynamic balance, balance confidence and fear of falling, may play important roles in executing rapid steps in older adults. Motor performance and psychological indicators of balance-related confidence appear to have crucial roles in SET in older adults. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Visually-salient contour detection using a V1 neural model with horizontal connections

    CERN Document Server

    Loxley, P N

    2011-01-01

    A convolution model which accounts for neural activity dynamics in the primary visual cortex is derived and used to detect visually salient contours in images. Image inputs to the model are modulated by long-range horizontal connections, allowing contextual effects in the image to determine visual saliency, i.e. line segments arranged in a closed contour elicit a larger neural response than line segments forming background clutter. The model is tested on 3 types of contour, including a line, a circular closed contour, and a non-circular closed contour. Using a modified association field to describe horizontal connections the model is found to perform well for different parameter values. For each type of contour a different facilitation mechanism is found. Operating as a feed-forward network, the model assigns saliency by increasing the neural activity of line segments facilitated by the horizontal connections. Alternatively, operating as a feedback network, the model can achieve further improvement over sever...

  7. Feasibility of progressive sit-to-stand training among older hospitalized patients

    DEFF Research Database (Denmark)

    Pedersen, Mette Merete; Petersen, Janne; Bean, Jonathan F

    2015-01-01

    and dose for older patients. Therefore, our aim was to test the feasibility of a progression model for loaded sit-to-stand training among older hospitalized patients. Methods. This is a prospective cohort study conducted as a feasibility study prior to a full-scale trial. We included twenty-four older...... patients (≥65 yrs) acutely admitted from their own home to the medical services of the hospital. We developed an 8-level progression model for loaded sit-to-stands, which we named STAND. We used STAND as a model to describe how to perform the sit-to-stand exercise as a strength training exercise aimed......Background. In older patients, hospitalization is associated with a decline in functional performance and loss of muscle strength. Loss of muscle strength and functional performance can be prevented by systematic strength training, but details are lacking regarding the optimal exercise program...

  8. DESIGN OF A SUPERBIKE PADDOCK STAND USING CAD AND CAE TOOLS

    Directory of Open Access Journals (Sweden)

    M.H. Mohd Noh

    2012-06-01

    Full Text Available Two people are required to operate current superbike paddock stands in order to elevate the superbike. Lifting the superbike alone using the current design of paddock stand may be impractical and inconvenient for users. To overcome this limitation, a new design of a superbike paddock stand was conceived that could be operated by a single user. CAD and CAE tools using CATIA V5R18 software were utilised in designing this new stand. A 3D CAD model was developed and analysed through finite element analysis (FEA and a prototype fabricated for verification testing of the design. The use of CAD and CAE tools saved much time in the design work and gave the researchers and designers freedom in producing their own design. However, the most important aspect of this design study was to design a superbike paddock stand that is more practical and convenient for operation by a single user.

  9. Impact of Acoustic Standing Waves on Structural Responses

    Science.gov (United States)

    Kolaini, Ali R.

    2014-01-01

    For several decades large reverberant chambers and most recently direct field acoustic testing have been used in the aerospace industry to test larger structures with low surface densities such as solar arrays and reflectors to qualify them and to detect faults in the design and fabrication. It has been reported that in reverberant chamber and direct acoustic testing, standing acoustic modes may strongly couple with the fundamental structural modes of the test hardware (Reference 1). In this paper results from a recent reverberant chamber acoustic test of a composite reflector are discussed. These results provide further convincing evidence of the acoustic standing wave and structural modes coupling phenomenon. The purpose of this paper is to alert test organizations to this phenomenon so that they can account for the potential increase in structural responses and ensure that flight hardware undergoes safe testing. An understanding of the coupling phenomenon may also help minimize the over and/or under testing that could pose un-anticipated structural and flight qualification issues.

  10. Flow under standing waves Part 1. Shear stress distribution, energy flux and steady streaming

    DEFF Research Database (Denmark)

    Gislason, Kjartan; Fredsøe, Jørgen; Deigaard, Rolf

    2009-01-01

    The conditions for energy flux, momentum flux and the resulting streaming velocity are analysed for standing waves formed in front of a fully reflecting wall. The exchange of energy between the outer wave motion and the near bed oscillatory boundary layer is considered, determining the horizontal...... energy flux inside and outside the boundary layer. The momentum balance, the mean shear stress and the resulting time averaged streaming velocities are determined. For a laminar bed boundary layer the analysis of the wave drift gives results similar to the original work of Longuet-Higgins from 1953...

  11. Visual evoked responses during standing and walking

    Directory of Open Access Journals (Sweden)

    Klaus Gramann

    2010-10-01

    Full Text Available Human cognition has been shaped both by our body structure and by its complex interactionswith its environment. Our cognition is thus inextricably linked to our own and others’ motorbehavior. To model brain activity associated with natural cognition, we propose recording theconcurrent brain dynamics and body movements of human subjects performing normal actions.Here we tested the feasibility of such a mobile brain/body (MoBI imaging approach byrecording high-density electroencephalographic (EEG activity and body movements of subjectsstanding or walking on a treadmill while performing a visual oddball response task. Independentcomponent analysis (ICA of the EEG data revealed visual event-related potentials (ERPs thatduring standing, slow walking, and fast walking did not differ across movement conditions,demonstrating the viability of recording brain activity accompanying cognitive processes duringwhole body movement. Non-invasive and relatively low-cost MoBI studies of normal, motivatedactions might improve understanding of interactions between brain and body dynamics leadingto more complete biological models of cognition.

  12. Relationship between morphologic somatotypes and standing posture equilibrium.

    Science.gov (United States)

    Allard, P; Nault, M L; Hinse, S; LeBlanc, R; Labelle, H

    2001-01-01

    Previous studies have identified height and weight as important factors affecting quiet standing stability but studies have not addressed body morphology as a global factor. Using anthropometric measurements, the morphologic somatotypes were defined in terms of body composition and structure. The aim of this study was to test the hypothesis that morphologic somatotypes were related to standing posture equilibrium in able-bodied girls. A total of 43 able-bodied girls having a mean age of 13.8 +/- 2.2 years participated in this study. Somatotype measurements were taken to determine their endomorphic, mesomorphic or ectomorphic components. Then, subjects were asked to stand still on a force platform for 64 s with their eyes opened, feet about 23 cm apart and arms aligned with the trunk. Afterwards, subjects were grouped based on the highest value of their somatotype component. There was no statistical difference in age, height and weight among the groups. The surface area of an ellipse delineated by the displacement of the centre of pressure (COP) was statistically larger (236.9 +/- 134.3 mm2) for the ectomorphs than for the endomorphs 137.7 +/- 71.4 mm2). The minor axis was longer (8.1 +/- 2.9 mm) for the ectomorphs than for the endomorphs (5.7 +/- 2.2 mm). The decrease in standing posture stability of the ectomorphic group was attributed to a relatively low muscle component, a high height weight ratio and an elevated position of the body centre of mass in this population of girls. Somatotypes should be considered when assessing standing posture in both able-bodied subjects and patients.

  13. Measuring Diagnostic Stand for Experimental Researches in Technology Machining

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2014-01-01

    Full Text Available The paper reviews applied techniques, methods, and structure of the control and measuring means to conduct experimental and scientific researches of cutting processes. Existing research methods in cutting the metals are divided by features, such as essence of methods, the number of records of physical indicators, the number of studied factors, duration of tests. The groups of methods are briefly characterized.The chair "Tool Engineering and Technologies" of BMSTU developed and made a diagnostic stand of control and measurements for conducting research activities in the field of materials processing technology by cutting to define rational technological decisions, when machining, and carry out an analysis of efficiency and economic feasibility of made decisions. The diagnostic stand contains modern the electronic equipment. Record of measuring parameters is made in real time with a possibility for visual representation of read results and mathematical and statistical processing of measurement results. The stand can be used in research laboratories of machine-building enterprises, laboratories of higher education institutions, and other scientific divisions.The paper presents a justification that the stand is reasonable to use for the following: completion and choice of rational cutting modes, workability assessment of new constructional materials, technical and operational characteristics of the processed surfaces, and operational properties of the cutting tools of various producers, choice of optimum geometrical parameters of the cutting tools and brands of the lubricant cooling technological means, as well as the energy consumption for the chosen machining process. The stand allows us to make an assessment of wear resistance and tribology-technical characteristics of tool materials, as well as an accuracy, rigidity, vibration stability of machines, both new and being in operation.

  14. Horizontal gene transfer in evolution: facts and challenges

    OpenAIRE

    Boto, Luis

    2009-01-01

    The contribution of horizontal gene transfer to evolution has been controversial since it was suggested to be a force driving evolution in the microbial world. In this paper, I review the current standpoint on horizontal gene transfer in evolutionary thinking and discuss how important horizontal gene transfer is in evolution in the broad sense, and particularly in prokaryotic evolution. I review recent literature, asking, first, which processes are involved in the evolutionary success of tran...

  15. Capillary-contacting horizontal cells in the rodent retina

    OpenAIRE

    Mojumder, Deb Kumar

    2008-01-01

    Horizontal cells, the interneurons in the distal retina, provide feedback control of the photoreceptor synaptic output at the first synapse in the visual pathway. This article, using immunohistological and confocal microscopy techniques, presents anatomical evidence that in rat and mouse retina, the horizontal cell processes are in contact with retinal capillaries as are retinal glial cells. This glia-like property of horizontal cells in these two species, also previously reported in tree shr...

  16. Vestibulopathy and the age effects on protective stepping during unperturbed standing.

    Science.gov (United States)

    Krebs, D E; Velyvis, P H; Rogers, M W

    2000-07-01

    This study examined the prevalence of protective stepping and accompanying preparatory postural responses associated with lateral weight transfer (WT) while subjects attempted to sustain stationary standing. The subjects were 92 healthy young and older adults and persons with vestibular hypofunction. Force platform and whole-body-motion recordings were used to evaluate the prevalence of stepping and WT responses during stationary standing (eyes open or closed) using a semi-tandem foot position. WT components were also evaluated for volitionally requested step initiation, and as a function of support base configuration and direction of stepping among younger subjects. Only 10% of trials by subjects with bilateral vestibular hypofunction (BVH) during semi-tandem standing with eyes closed were completed without a step, while 31% of subjects with UVH, 69% of healthy elders, and all young healthy subjects were able to stand for the entire 7-sec trials. WT responses always preceded volitional steps from a standard feet-parallel orientation but occurred in only 13% of the spontaneous steps. The prevalence of WT was influenced by the direction of volitional stepping from semi-tandem standing, but not by the initial standing width. Spontaneous stepping to maintain standing balance is a naturally occurring and prevalent behavior among older adults and persons with vestibular hypofunction during tests of quasi-static standing. Differences between volitional and spontaneous step initiation involving the prevalence of preparatory lateral WT are a complex function of motor planning, mechanical constraints, and functional context.

  17. Characterizing local variability in long‐period horizontal tilt noise

    Science.gov (United States)

    Rohde, M.D.; Ringler, Adam; Hutt, Charles R.; Wilson, David; Holland, Austin; Sandoval, L.D; Storm, Tyler

    2017-01-01

    Horizontal seismic data are dominated by atmospherically induced tilt noise at long periods (i.e., 30 s and greater). Tilt noise limits our ability to use horizontal data for sensitive seismological studies such as observing free earth modes. To better understand the local spatial variability of long‐period horizontal noise, we observe horizontal noise during quiet time periods in the Albuquerque Seismological Laboratory (ASL) underground vault using four small‐aperture array configurations. Each array comprises eight Streckeisen STS‐2 broadband seismometers. We analyze the spectral content of the data using power spectral density and magnitude‐squared coherence (γ2‐coherence). Our results show a high degree of spatial variability and frequency dependence in the long‐period horizontal wavefield. The variable nature of long‐period horizontal noise in the ASL vault suggests that it might be highly local in nature and not easily characterized by simple physical models when overall noise levels are low, making it difficult to identify locations in the vault with lower horizontal noise. This variability could be limiting our ability to apply coherence analysis for estimating horizontal sensor self‐noise and could also complicate various indirect methods for removing long‐period horizontal noise (e.g., collocated rotational sensor or microbarograph).

  18. The Impact of Horizontal Mergers on Competition: A Literature Survey

    Directory of Open Access Journals (Sweden)

    Sevilay SARICA

    2012-06-01

    Full Text Available A large number of studies have been devoted to the effects of horizontal mergers on competition. This survey intends to review some selected studies about the effects of competition on horizontal mergers with a special attention given the horizontal integration. One of the important results obtained from this literature survey is that the findings of many researches have largely been controversial due to the different approaches and the time periods used in their studies. In these studies, even though it has been proved that horizontal mergers have negative effects on competition, it is not possible to make any precise comment on the dimension of this effect.

  19. Cuttings Transport Models and Experimental Visualization of Underbalanced Horizontal Drilling

    Directory of Open Access Journals (Sweden)

    Na Wei

    2013-01-01

    Full Text Available Aerated underbalanced horizontal drilling technology has become the focus of the drilling industry at home and abroad, and one of the engineering core issues is the horizontal borehole cleaning. Therefore, calculating the minimum injection volume of gas and liquid accurately is essential for the construction in aerated underbalanced horizontal drilling. This paper establishes a physical model of carrying cuttings and borehole cleaning in wellbore of horizontal well and a critical transport mathematical model according to gas-liquid-solid flow mechanism and large plane dunes particle transport theory.

  20. Lusin approximation for horizontal curves in step 2 Carnot groups

    OpenAIRE

    Donne, Enrico Le; Speight, Gareth

    2016-01-01

    A Carnot group $\\mathbb{G}$ admits Lusin approximation for horizontal curves if for any absolutely continuous horizontal curve $\\gamma$ in $\\mathbb{G}$ and $\\varepsilon>0$, there is a $C^1$ horizontal curve $\\Gamma$ such that $\\Gamma=\\gamma$ and $\\Gamma'=\\gamma'$ outside a set of measure at most $\\varepsilon$. We verify this property for free Carnot groups of step 2 and show that it is preserved by images of Lie group homomorphisms preserving the horizontal layer. Consequently, all step 2 Car...

  1. Misdirected horizontal saccades in pan-cerebellar atrophy.

    Science.gov (United States)

    Shaikh, Aasef G; Ghasia, Fatema F

    2015-08-15

    Saccadic dysmetria is a sensitive marker of cerebellar dysfunction. We discovered misdirected horizontal saccades due to cross-coupled orthogonal (vertical) saccades in siblings with pan-cerebellar atrophy. There was an upward drift in vertical eye position after each cross-coupled downward saccade. Such drifts brought the eyes back to the desired target. Due to strong upward bias, downward compensatory slow movements did not follow cross-coupled upward saccades. There was minimal horizontal cross-coupling associated with vertical saccades. There was a reduced gain of horizontal pursuit causing lag in the horizontal eye movement and subsequent catch-up horizontal saccades. The horizontal catch-up saccades were also associated with vertical cross-coupled eye movements and subsequent drifts. There was no cross-coupling of pursuit eye movements. Our results support the hypothesis emphasizing adaptive cerebellar control of saccade direction. Commands for horizontal saccades trigger not only the activity of the horizontal burst generators, but also the vertical burst neurons. The activity of orthogonal (vertical) burst neurons is canceled by opposing signals under cerebellar supervision. Cerebellar lesions could disrupt such balance between opposing orthogonal signals leading to vertical cross-coupling during horizontal saccade. We speculate that upward drift might result from an imbalance in opposing orthogonal signals at the level of neural integrators. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. 1 Reevaluation of the integrated horizontal flux approach

    Science.gov (United States)

    Neftel, Albrecht; Häni, Christoph; Hensen, Arjan

    2017-04-01

    The integrated horizontal flux (IHF) method is a simplified mass balance approach frequently used to determine emissions from confined source areas, e.g. NH3 emissions from slurry spread to a circular plot (Denmead, 2008). With a mast in the center of the circle with radius R, the total flux F of the upwind emitted NH3 is approximated from the measured vertical (z) profiles of concentration (c) and horizontal wind speed (u) as (Denmead 1983): F = 1/R\\intz=zplz=0\\overline{u(c - cbgd)}dz where cbgd is the ``background'' concentration upwind of the emitting area and zpl is the maximum height of the emission plume (where the concentration c equals cbgd).The IHF method is a robust approach, as it is independent of surface characteristics and the state of atmospheric diffusion (Denmead, 2008; Laubach,2010). Ryden and McNeill (1984) published guidelines on how to evaluate IHF measurements, which have been used in many investigations that followed. In the following we analyze systematic biases that might occur by applying different recipes to both modelled concentration profiles as well as measured profiles from a recent field experiment in the Netherlands. Typical differencs using the approach by Ryden et al. (1984) are in the order +10% to +30% compared to the reference values from the model or alternative determination of the emissions based on the experimental values. The positive biases consist of several contributions: horizontal diffusion, logarithmic fit of the concentration profile, displacement height. References Denmead, O. T., 1983. Micrometeorological methods for measuring gaseous losses of nitrogen in the field. In: Gaseous Loss of Nitrogen from Plum-Soil Systems (Freney, J. R.; Simpson, J. R., Eds) Martinus Nijhof/Dr W. Junk, The Hague, pp. 133-157. Denmead, O. T., 2008. Approaches to measuring fluxes of methane and nitrous oxide between landscapes and the atmosphere. Plant Soil 309 (1-2), 5a\\euro 24.Laubach, J., 2010. Testing of a lagrangian model of

  3. A Physically Based Horizontal Subgrid-scale Turbulent Mixing Parameterization for the Convective Boundary Layer in Mesoscale Models

    Science.gov (United States)

    Zhou, Bowen; Xue, Ming; Zhu, Kefeng

    2017-04-01

    Compared to the representation of vertical turbulent mixing through various PBL schemes, the treatment of horizontal turbulence mixing in the boundary layer within mesoscale models, with O(10) km horizontal grid spacing, has received much less attention. In mesoscale models, subgrid-scale horizontal fluxes most often adopt the gradient-diffusion assumption. The horizontal mixing coefficients are usually set to a constant, or through the 2D Smagorinsky formulation, or in some cases based on the 1.5-order turbulence kinetic energy (TKE) closure. In this work, horizontal turbulent mixing parameterizations using physically based characteristic velocity and length scales are proposed for the convective boundary layer based on analysis of a well-resolved, wide-domain large-eddy simulation (LES). The proposed schemes involve different levels of sophistication. The first two schemes can be used together with first-order PBL schemes, while the third uses TKE to define its characteristic velocity scale and can be used together with TKE-based higher-order PBL schemes. The current horizontal mixing formulations are also assessed a priori through the filtered LES results to illustrate their limitations. The proposed parameterizations are tested a posteriori in idealized simulations of turbulent dispersion of a passive scalar. Comparisons show improved horizontal dispersion by the proposed schemes, and further demonstrate the weakness of the current schemes.

  4. Basic Stand Alone Medicare Outpatient Procedures PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Outpatient Procedures Public Use Files (PUF) with information from Medicare outpatient claims. The CMS BSA...

  5. RLC Forest Stand Carbon Map of Russia

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This dataset is a 1:15 million scale map of forest stand carbon for the land area of Russia (Stone et al., 2000). The objective was to create a first...

  6. RLC Forest Stand Carbon Map of Russia

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset is a 1:15 million scale map of forest stand carbon for the land area of Russia (Stone et al., 2000). The objective was to create a first approximation...

  7. Minnesota DNR Forest Stand Inventory Version 2

    Data.gov (United States)

    Minnesota Department of Natural Resources — This layer is a digital inventory of individual forest stands. The data is collected by DNR Foresters in each DNR Forestry Administrative Area, and is updated on a...

  8. 1990 sampling of treated aspen stands

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — In mid-August, 1990, sampling of aspen stand exclosures were conducted at the National Elk Refuge. This sampling is part of a study to monitor aspen regeneration on...

  9. Basic Stand Alone Carrier Line Items PUF

    Data.gov (United States)

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Carrier Line Items Public Use Files (PUF) with information from Medicare Carrier claims. The CMS BSA Carrier Line...

  10. Species composition of developing Central Appalachian hardwood stands following clearcutting

    Science.gov (United States)

    Lance A. Vickers; Thomas Fox

    2015-01-01

    This study examined the species composition of 47 paired stands on submesic sites on the Appalachian Plateau of West Virginia. Paired stands consisted of a mature stand adjacent to a young clearcut that was

  11. Stand and within-stand factors influencing Golden-winged Warbler use of regenerating stands in the central Appalachian Mountains

    Directory of Open Access Journals (Sweden)

    Marja H. Bakermans

    2015-06-01

    Full Text Available The Golden-winged Warbler (Vermivora chrysoptera is currently being considered for protected status under the U.S. Endangered Species Act. The creation of breeding habitat in the Appalachian Mountains is considered a conservation priority for this songbird, which is dependent on extensively forested landscapes with adequate availability of young forest. We modeled abundance of Golden-winged Warbler males in regenerating harvested forest stands that were 0-17 years postharvest at both mid-Appalachian and northeast Pennsylvania regional scales using stand and within-stand characteristics of 222 regenerating stands, 2010-2011. Variables that were most influential at the mid-Appalachian scale were different than those in the northeast region. Across the mid-Appalachian ecoregion, the proportion of young forest cover, i.e., shrub/scrub cover, within 1 km of regenerating stands best explained abundance of Golden-winged Warblers. Golden-winged Warbler response was best explained by a concave quadratic relationship in which abundance was highest with 5-15% land in young forest cover. We also found evidence that the amount of herbaceous cover, i.e., the amount of grasses and forbs, within a regenerating stand positively influenced abundance of Golden-winged Warblers. In northeastern Pennsylvania, where young forest cover is found in high proportions, the distance to the nearest regenerating stand best explained variation in abundance of Golden-winged Warblers. Abundance of Golden-winged Warblers was 1500 m away. When modeling within-stand features in the northeast region, many of the models were closely ranked, indicating that multiple variables likely explained Golden-winged Warbler response to within-stand conditions. Based on our findings, we have proposed several management guidelines for land managers interested in creating breeding habitat for Golden-winged Warblers using commercial timber operations. For example, we recommend when managing for

  12. Environmental Test Facility (ETF)

    Data.gov (United States)

    Federal Laboratory Consortium — The Environmental Test Facility (ETF) provides non-isolated shock testing for stand-alone equipment and full size cabinets under MIL-S-901D specifications. The ETF...

  13. Laboratory Stands for Wideband Analysis Radiocommunication Signals

    OpenAIRE

    Studanski, Ryszard; Was, Radosław; Studanska, Agnieszka; Garus, Jarosław

    2012-01-01

    A laboratory stand for wideband analysis radiocommunication signals is presented in the paper. The stand is designed for signals acquisition in wide spectrum and research a field of digital signal processing. Procedures used for simultaneous acquiring many frequency channels in selected wide band are described. The method of detection of direct sequence spread spectrum signals (DS SS) which power spectral density is lower than noise is also discussed. Executed research were performed with sig...

  14. Gravity where do we stand ?

    CERN Document Server

    Colpi, Monica; Gorini, Vittorio; Moschella, Ugo

    2016-01-01

    This book presents an overview of the current understanding of gravitation, with a focus on the current efforts to test its theories, especially general relativity. It shows how the quest for a deeper understanding, which would possibly incorporate gravity in the quantum realm, is more than ever an open field. The majority of the contributions deals with the manifold facets of “experimental gravitation”, but the book goes beyond this and covers a broad range of subjects from the foundations of gravitational theories to astrophysics and cosmology. The book is divided into three parts. The first part deals with foundations and Solar System tests. An introductory pedagogical chapter reviews first Newtonian gravitational theory, special relativity, the equivalence principle and the basics of general relativity. Then it focuses on approximation methods, mainly the post-Newtonian formalism and the relaxed Einstein equations, with a discussion on how they are used in treating experimental tests and in the proble...

  15. Determinants of Human Immunodeficiency Virus (HIV prevalence in homosexual and bisexual men screened for admission to a cohort study of HIV negatives in Belo Horizonte, Brazil: Project Horizonte

    Directory of Open Access Journals (Sweden)

    Carneiro Mariângela

    2003-01-01

    Full Text Available Project Horizonte, an open cohort of homosexual and bisexual human immunodeficiency virus (HIV-1 negative men, is a component of the AIDS Vaccine Program, in Belo Horizonte, Minas Gerais, Brazil. The objective of this study was to compare volunteers testing HIV positive at cohort entry with a sample of those who tested HIV negative in order to identify risk factors for prevalent HIV infection, in a population being screened for enrollment at Project Horizonte. A nested case-control study was conducted. HIV positive volunteers at entry (cases were matched by age and admission date to three HIV negative controls each. Selected variables used for the current analysis included demographic factors, sexual behavior and other risk factors for HIV infection. During the study period (1994-2001, among the 621 volunteers screened, 61 tested positive for HIV. Cases were matched to 183 HIV negative control subjects. After adjustments, the main risk factors associated with HIV infection were unprotected sex with an occasional partners, OR = 3.7 (CI 95% 1.3-10.6, receptive anal intercourse with an occasional partner, OR = 2.8 (95% CI 0.9-8.9 and belonging to the negro racial group, OR = 3.4 (CI 95% 1.1-11.9. These variables were associated with an increase in the risk of HIV infection among men who have sex with men at the screening for admission to an open HIV negative cohort.

  16. How a plantar pressure-based, tongue-placed tactile biofeedback modifies postural control mechanisms during quiet standing

    CERN Document Server

    Vuillerme, Nicolas; Chenu, Olivier; Boisgontier, Matthieu; Demongeot, Jacques; Payan, Yohan

    2007-01-01

    The purpose of the present study was to determine the effects of a plantar pressure-based, tongue-placed tactile biofeedback on postural control mechanisms during quiet standing. To this aim, sixteen young healthy adults were asked to stand as immobile as possible with their eyes closed in two conditions of No-biofeedback and Biofeedback. Centre of foot pressure (CoP) displacements, recorded using a force platform, were used to compute the horizontal displacements of the vertical projection the centre of gravity (CoGh) and those of the difference between the CoP and the vertical projection of the CoG (CoP-CoGv). Altogether, the present findings suggest that the main way the plantar pressure-based, tongue-placed tactile biofeedback improves postural control during quiet standing is via both a reduction of the correction thresholds and an increased efficiency of the corrective mechanism involving the CoGh displacements.

  17. Birch Stands Growth Increase in Western Siberia

    Science.gov (United States)

    Kharuk, Viacheslav I.; Kuzmichev, Valeriy V.; Im, Sergey T.; Ranson, Kenneth J.

    2014-01-01

    Birch (Betula pendula Roth) growth within the Western Siberia forest-steppe was analyzed based on long-term (1897-2006) inventory data (height, diameter at breast height [dbh], and stand volume). Analysis of biometry parameters showed increased growth at the beginning of twenty-first century compared to similar stands (stands age = 40-60 years) at the end of nineteenth century. Mean height, dbh, and stem volume increased from 14 to 20 m, from 16 to 22 cm, and from approx. 63 to approx. 220 cu m/ha, respectively. Significant correlations were found between the stands mean height, dbh, and volume on the one hand, and vegetation period length (r(sub s) = 0.71 to 0.74), atmospheric CO2 concentration (r(sub s) = 0.71 to 0.76), and drought index (Standardized Precipitation-Evapotranspiration Index, r(sub s) = -0.33 to -0.51) on the other hand. The results obtained have revealed apparent climate-induced impacts (e.g. increase of vegetation period length and birch habitat drying due to drought increase) on the stands growth. Along with this, a high correlation of birch biometric parameters and [CO2] in ambient air indicated an effect of CO2 fertilization. Meanwhile, further drought increase may switch birch stand growth into decline and greater mortality as has already been observed within the Trans-Baikal forest-steppe ecotone.

  18. Yield tables for Italian coppice stands

    Energy Technology Data Exchange (ETDEWEB)

    Bernetti, G.

    1980-01-01

    A critical review of results from 32 yield tables for Italian coppice stands. Particular attention is paid to age of maximum m.a.i., distribution of total volume of fuelwood up to 3 cm in diameter and of brushwood, and relation between mean height and volume. A provisional general yield table is given for Quercus cerris and mixed deciduous coppice stands, based on data from 12 local tables. Maximum m.a.i. occurs relatively early, with rather low values. For Quercus ilex and mixed evergreen broadleaved coppice stands on the coast of Tuscany, tables perpared separately by Giordano and Patrone are broadly in agreement. In terms of total volume, the evergreen coppice stands of the Mediterranean maquis have a higher yield than deciduous coppice stands, and contain a higher % of brushwood. Data for Fagus sylvatica are somewhat incomplete, but m.a.i. for fuelwood appears to remain constant between the ages of 12 and 24, with maximum values of 5 and 2.1 cu.m/ha for the best and poorest quality classes respectively. Castanea sativa coppice stands can show very high rates of increment e.g. maximum m.a.i. of 20 cu.m/ha on highly fertile volcanic soils.

  19. Processing of Horizontal Sound Localization Cues in Newborn Infants.

    Science.gov (United States)

    Németh, Renáta; Háden, Gábor P; Török, Miklós; Winkler, István

    2015-01-01

    By measuring event-related brain potentials (ERPs), the authors tested the sensitivity of the newborn auditory cortex to sound lateralization and to the most common cues of horizontal sound localization. Sixty-eight healthy full-term newborn infants were presented with auditory oddball sequences composed of frequent and rare noise segments in four experimental conditions. The authors tested in them the detection of deviations in the primary cues of sound lateralization (interaural time and level difference) and in actual sound source location (free-field and monaural sound presentation). ERP correlates of deviance detection were measured in two time windows. Deviations in both primary sound localization cues and the ear of stimulation elicited a significant ERP difference in the early (90 to 140 msec) time window. Deviance in actual sound source location (the free-field condition) elicited a significant response in the late (290 to 340 msec) time window. The early differential response may indicate the detection of a change in the respective auditory features. The authors suggest that the late differential response, which was only elicited by actual sound source location deviation, reflects the detection of location deviance integrating the various cues of sound source location. Although the results suggest that all of the tested binaural cues are processed by the neonatal auditory cortex, utilizing the cues for locating sound sources of these cues may require maturation and learning.

  20. Directed growth of horizontally aligned gallium nitride nanowires for nanoelectromechanical resonator arrays.

    Science.gov (United States)

    Henry, Tania; Kim, Kyungkon; Ren, Zaiyuan; Yerino, Christopher; Han, Jung; Tang, Hong X

    2007-11-01

    We report the growth of horizontally aligned arrays and networks of GaN nanowires (NWs) as resonant components in nanoelectromechanical systems (NEMS). A combination of top-down selective area growth (SAG) and bottom-up vapor-liquid-solid (VLS) synthesis enables flexible fabrication of highly ordered nanowire arrays in situ with no postgrowth dispersion. Mechanical resonance of free-standing nanowires are measured, with quality factors (Q) ranging from 400 to 1000. We obtained a Young's modulus (E) of approximately 338 GPa from an array of NWs with varying diameters and lengths. The measurement allows detection of nanowire motion with a rotating frame and reveals dual fundamental resonant modes in two orthogonal planes. A universal ratio between the resonant frequencies of these two fundamental modes, irrespective of their dimensions, is observed and attributed to an isosceles cross section of GaN NWs.

  1. Bubble growth in a narrow horizontal space

    Energy Technology Data Exchange (ETDEWEB)

    Stutz, Benoit; Goulet, Remi [CETHIL, UMR5008, CNRS, INSA-Lyon, Universite Lyon1 (France); Passos, Julio Cesar [Universidade Federal de Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica. LABSOLAR

    2009-07-01

    The purpose of this work is to develop an axis-symmetric two-phase flow model describing the growth of a single bubble squeezed between a horizontal heated upward-facing disc and an insulating surface placed parallel to the heated surface. Heat transfers at the liquid-vapour interfaces are predicted by the kinetic limit of vaporisation. The depths of the liquid films deposed on the surfaces (heated surface and confinement space) are determined using the Moriyama and Inoue correlation (1996). Transient heat transfers within the heated wall are taken into account. The model is applied to pentane bubble growth. The influence of the gap size, the initial temperature of the system, the thermal effusivity of the heated wall and the kinetic limit of vaporisation are studied. The results show that the expansion of the bubbles strongly depends on the gap size and can be affected by the effusivity of the material. Mechanical inertia effects are mainly dominant at the beginning of the bubble expansion. Pressure drop induced by viscous effects have to be taken into account for high capillary numbers. Heat transfers at the meniscus are negligible except at the early stages of the bubble growth. (author)

  2. Horizontal Shear Wave Imaging of Large Optics

    Energy Technology Data Exchange (ETDEWEB)

    Quarry, M J

    2007-09-05

    When complete the National Ignition Facility (NIF) will be the world's largest and most energetic laser and will be capable of achieving for the first time fusion ignition in the laboratory. Detecting optics features within the laser beamlines and sizing them at diameters of 0.1 mm to 10 mm allows timely decisions concerning refurbishment and will help with the routine operation of the system. Horizontally polarized shear waves at 10 MHz were shown to accurately detect, locate, and size features created by laser operations from 0.5 mm to 8 mm by placing sensors at the edge of the optic. The shear wave technique utilizes highly directed beams. The outer edge of an optic can be covered with shear wave transducers on four sides. Each transducer sends a pulse into the optic and any damage reflects the pulse back to the transmitter. The transducers are multiplexed, and the collected time waveforms are enveloped and replicated across the width of the element. Multiplying the data sets from four directions produces a map of reflected amplitude to the fourth power, which images the surface of the optic. Surface area can be measured directly from the image, and maximum depth was shown to be correlated to maximum amplitude of the reflected waveform.

  3. On the modulation of wave-current interactions by horizontal mixing and spatial resolution

    Science.gov (United States)

    Bennis, A. C.; Ardhuin, F.; Dumas, F.; Blanke, B.

    2016-02-01

    The mechanics of rip currents are complex, involving interactions between waves, currents, water levels and bathymetry that pose particular challenges for numerical models. Horizontal turbulent diffusion in a rip system is difficult to measure using dye dilution or surfzone drifters, as shown by the range of published values for the horizontal diffusion coeffcient. Here, we study the effects of horizontal mixing on wave-current interactions by testing several diffusivity estimates in a fully coupled 3D wave-current model run at two different spatial resolution. Published results using very low diffusion have found near the shore the wave rays converge towards the rip channel because of refraction by the currents. We show that this process depends on the alongshore gradient of the rip current and that this gradient is modulated by both horizontal mixing and spatial resolution. We find that without the feedback of currents on waves, the flow is more sensitive to horizontal mixing with large alterations especially offshore and generally lower velocities. These modifications ascribed to mixing are similar to those induced by the feedback mechanism. When a large mixing coeffcient is used, we observe that: i) the behavior of the rip system is similar for both coupling modes (i.e. with and without the feedback of currents on waves) and for each resolution, ii) the evolution of the flow is more stable over time. Lastly, we show that the horizontal mixing strongly decreases the intensity of the 3D rip velocity, but not its vertical shear that is strongly dependent on the vertical mixing scheme and on the forcing terms.

  4. Staged fracturing of horizontal shale gas wells with temporary plugging by sand filling

    Directory of Open Access Journals (Sweden)

    Xing Liang

    2017-03-01

    Full Text Available Due to downhole complexities, shale-gas horizontal well fracturing in the Sichuan Basin suffered from casing deformation and failure to apply the technique of cable-conveyed perforation bridge plug. In view of these problems, a new technique of staged volume fracturing with temporary plugging by sand filling is employed. Based on theoretical analyses and field tests, a design of optimized parameters of coiled tubing-conveyed multi-cluster sand-blasting perforation and temporary plugging by sand filling was proposed. It was applied in the horizontal Well ZJ-1 in which casing deformation occurred. The following results are achieved in field operations. First, this technique enables selective staged fracturing in horizontal sections. Second, this technique can realize massive staged fracturing credibly without mechanical plugging, with the operating efficiency equivalent to the conventional bridge plug staged fracturing. Third, full-hole is preserved after fracturing, thus it is possible to directly conduct an open flow test without time consumption of a wiper trip. The staged volume fracturing with temporary plugging by sand filling facilitated the 14-stage fracturing in Well ZJ-1, with similar SRV to that achieved by conventional bridge plug staged fracturing and higher gas yield than neighboring wells on the same well pad. Thus, a new and effective technique is presented in multi-cluster staged volume fracturing of shale gas horizontal wells.

  5. Analysis of Horizontal Accuracy for Large Scale Rural Mapping Using Rotary Wing UAV Image

    Science.gov (United States)

    Hidayat, Husnul; Muljo Sukojo, Bangun

    2017-12-01

    In order to fulfil the need of large scale map for rural mapping, Indonesian government is now looking for alternatives of geospatial data sources. With newly developed technology, nowadays rotary wing UAV can be used to acquire very high resolution aerial imagery quickly with low cost. This research assesses the horizontal accuracy of rural mapping in 1:2000 scale using orthophoto derived from rotary wing UAV image data. The test site of this research is Kebonwaris village, Pandaan, East Java which has an area of approximately 167 hectares. Image data was taken with approximately 80% overlap each other and processed using Structure from Motion approach. Twelve GCPs coordinates were measured using differential GPS observations for georeferencing purpose. For accuracy assessment, 22 test points were established and their coordinates were measured using static differential GPS observations. The results show that the mean absolute horizontal errors are 0.071 m and 0.142 m for easting and northing respectively and the Root Mean Square Errors are 0.088 m and 0.169 m for easting and northing respectively. These RMSE values represents horizontal RMSE 0.190 m. According to Peraturan Kepala BIG No. 15 Tahun 2014, this RMSE value represents the 0.289 m horizontal accuracy based on CE90 criterion. Therefore, with this level of accuracy the UAV image data can be used to make a class 1 base map in 1:2500 scale or class 2 base map in 1:1000 scale.

  6. Photovoltaic stand-alone modular systems, phase 2

    Science.gov (United States)

    Naff, G. J.; Marshall, N. A.

    1983-01-01

    The final hardware and system qualification phase of a two part stand-alone photovoltaic (PV) system development is covered. The final design incorporated modular, power blocks capable of expanding incrementally from 320 watts to twenty kilowatts (PK). The basic power unit (PU) was nominally rated 1.28 kWp. The controls units, power collection buses and main lugs, electrical protection subsystems, power switching, and load management circuits are housed in a common control enclosure. Photo-voltaic modules are electrically connected in a horizontal daisy-chain method via Amp Solarlok plugs mating with compatible connectors installed on the back side of each photovoltaic module. A pair of channel rails accommodate the mounting of the modules into a frameless panel support structure. Foundations are of a unique planter (tub-like) configuration to allow for world-wide deployment without restriction as to types of soil. One battery string capable of supplying approximately 240 ampere hours nominal of carryover power is specified for each basic power unit. Load prioritization and shedding circuits are included to protect critical loads and selectively shed and defer lower priority or noncritical power demands. The baseline system, operating at approximately 2 1/2 PUs (3.2 kW pk.) was installed and deployed. Qualification was successfully complete in March 1983; since that time, the demonstration system has logged approximately 3000 hours of continuous operation under load without major incident.

  7. Towards a new natural theology based on horizontal transcendence ...

    African Journals Online (AJOL)

    As a result the article rejects absolute transcendence, replacing it with a horizontal transcendence that accords with humans' biological makeup and with presentday scientifi c thinking. In the framework of horizontal transcendence the pivotal problem of the human condition is no longer death, but life. This has radical ...

  8. The Interplay of Different Types of Governance in Horizontal Cooperations

    DEFF Research Database (Denmark)

    Raue, Jan Simon; Wieland, Andreas

    2015-01-01

    Purpose – Over the last decades, horizontal cooperations between logistics service providers (LSPs) have become a well-established organizational form and their use is expected to grow even further in the future. In spite of this increasing importance of horizontal LSP cooperations, little research...

  9. Horizontal cooperation in transport and logistics : A literature review

    NARCIS (Netherlands)

    Cruijssen, Frans; Dullaert, Wout; Fleuren, Hein

    This article presents a broad review of horizontal cooperation in transport and logistics. This topic is fast gaining momentum in the logistics sector and is thus highly relevant from a practical point of view. Moreover, horizontal cooperation is also interesting from a theoretical perspective

  10. Horizontal Cooperation in Transport and Logistics: A Literature Review

    NARCIS (Netherlands)

    Cruijssen, Frans; Dullaert, Wout; Fleuren, Hein

    2007-01-01

    This article presents a broad review of horizontal cooperation in transport and logistics. This topic is fast gaining momentum in the logistics sector and is thus highly relevant from a practical point of view. Moreover, horizontal cooperation is also interesting from a theoretical perspective

  11. District Power Equalization, Horizontal Equity and the Property Mix.

    Science.gov (United States)

    Hilley, John

    1980-01-01

    Argues that the traditional district power equalization (DPE) grant formula achieves horizontal equity, that the formula must be modified when the measure of fiscal capacity differs from the legal tax base, and that the inclusion of a tax exporting variable leads to the breakdown of horizontal equity. (Author/IRT)

  12. Processing woody biomass with a modified horizontal grinder

    Science.gov (United States)

    Dana Mitchell; John Klepac

    2008-01-01

    This study documents the production rate and cost of producing woody biomass chips for use in a power plant. The power plant has specific raw material handling requirements. Output from a 3-knife chipper, a tub grinder, and a horizontal grinder was considered. None of the samples from these machines met the specifications needed. A horizontal grinder was modified to...

  13. Investigation of blade performance of horizontal axis wind turbine ...

    African Journals Online (AJOL)

    The shape of rotor blade plays an important role in determining the overall aerodynamic performance of a horizontal axis wind turbine. In this work, blade is designed for a 5KW horizontal axis wind turbine which is already in market. For designing blade, blade element momentum theory (BEMT) is used and a computer ...

  14. Artificial remisión de V. horizonte artificial.

    OpenAIRE

    2011-01-01

    [ES] Definición del término Artificial remisión de V. horizonte artificial. en el diccionario Dicter. [EN] Definition of the word Artificial remisión de V. horizonte artificial. in the dictionary Dicter.

  15. APPLICATION OF WATER-JET HORIZONTAL DRILLING TECHNOLOGY TO DRILL AND ACIDIZE HORIZONTAL DRAIN HOLES, TEDBIT (SAN ANDRES) FIELD, GAINES COUNTY, TEXAS

    Energy Technology Data Exchange (ETDEWEB)

    Michael W. Rose

    2005-09-22

    The San Andres Formation is one of the major hydrocarbon-producing units in the Permian Basin, with multiple reservoirs contained within the dolomitized subtidal portions of upward shoaling carbonate shelf cycles. The test well is located in Tedbit (San Andres) Field in northeastern Gaines County, Texas, in an area of scattered San Andres production associated with local structural highs. Selected on the basis of geological and historical data, the Oil and Gas Properties Wood No. 1 well is considered to be typical of a large number of San Andres stripper wells in the Permian Basin. Thus, successful completion of horizontal drain holes in this well would demonstrate a widely applicable enhanced recovery technology. Water-jet horizontal drilling is an emerging technology with the potential to provide significant economic benefits in marginal wells. Forecast benefits include lower recompletion costs and improved hydrocarbon recoveries. The technology utilizes water under high pressure, conveyed through small-diameter coiled tubing, to jet horizontal drain holes into producing formations. Testing of this technology was conducted with inconclusive results. Paraffin sludge and mechanical problems were encountered in the wellbore, initially preventing the water-jet tool from reaching the kick-off point. After correcting these problems and attempting to cut a casing window with the water-jet milling assembly, lateral jetting was attempted without success.

  16. Erosion Characteristics and Horizontal Variability for Small Erosion Depths in the Sacramento - San Joaquin River Delta, California, USA

    Science.gov (United States)

    Schoellhamer, D. H.; Manning, A. J.; Work, P. A.

    2015-12-01

    Cohesive sediment in the Sacramento-San Joaquin River Delta affects pelagic fish habitat, contaminant transport, and marsh accretion. Observations of suspended-sediment concentration in the delta indicate that about 0.05 to 0.20 kg/m2 are eroded from the bed during a tidal cycle. If erosion is horizontally uniform, the erosion depth is about 30 to 150 microns, the typical range in diameter of suspended flocs. Application of an erosion microcosm produces similarly small erosion depths. In addition, core erodibility in the microcosm calculated with a horizontally homogeneous model increases with depth, contrary to expectations for a consolidating bed, possibly because the eroding surface area increases as applied shear stress increases. Thus, field observations and microcosm experiments, combined with visual observation of horizontally varying biota and texture at the surface of sediment cores, indicate that a conceptual model of erosion that includes horizontally varying properties may be more appropriate than assuming horizontally homogeneous erosive properties. To test this hypothesis, we collected five cores and measured the horizontal variability of shear strength within each core in the top 5.08 cm with a shear vane. Small tubes built by a freshwater worm and macroalgae were observed on the surface of all cores. The shear vane was inserted into the sediment until the top of the vane was at the top of the sediment, torque was applied to the vane until the sediment failed and the vane rotated, and the corresponding dial reading in Nm was recorded. The dial reading was assumed to be proportional to the surface strength. The horizontal standard deviation of the critical shear stress was about 30% of the mean. Results of the shear vane test provide empirical evidence that surface strength of the bed varies horizontally. A numerical simulation of erosion with an areally heterogeneous bed reproduced erosion characteristics observed in the microcosm.

  17. Long-term precommercial thinning effects on Larix occidentalis (western larch) tree and stand characteristics

    Science.gov (United States)

    Michael S. Schaedel; Andrew J. Larson; David L. R. Affleck; R. Travis Belote; John M. Goodburn; David K. Wright; Elaine Kennedy. Sutherland

    2017-01-01

    Precommercial thinning (PCT) is used to increase tree size and shorten harvest rotation time. Short-term results from PCT studies often show a trade-off between individual-tree growth and net stand yield, while longer-term effects of PCT on tree growth and stand yield are less well documented. We used a 54-year-old PCT study to test long-term effects of forest density...

  18. Simulations and scaling of horizontal convection

    Directory of Open Access Journals (Sweden)

    Mehmet ILIcak

    2012-05-01

    Full Text Available In this paper we describe the results of various numerical simulations of sideways or horizontal convection. Specifically, a two-dimensional Boussinesq fluid is both heated and cooled from its upper surface, but the walls and the bottom of the tank are insulating and have no flux of heat through them. We perform experiments with a range of Rayleigh numbers up to 1011, obtained by systematically reducing the diffusivity. We also explore the effects of a nonlinear equation of state and of a mechanical force imposed on the top surface at a fixed Rayleigh number. We find that, when there is no mechanical forcing, both the energy dissipation and the strength of the circulation itself monotonically fall with decreasing diffusivity. At Rayleigh numbers greater than 1010 the flow is unsteady; however, the eddying flow is still much weaker than the steady flow at smaller Rayleigh numbers. At high Rayleigh numbers, the stratification and the mean circulation are increasingly confined to a thin layer at the upper surface, with the layer thickness decreasing according to Ra−1/5. There is no evidence that the flow ever enters a regime that is independent of Rayleigh number. Using a nonlinear equation of state makes little difference to the flow phenomenology at a moderate Rayleigh number. The addition of an imposed stress at the upper surface makes a significant difference in the flow. A strong, energy-dissipating circulation can be maintained even at Ra = 109, and the stratification extends more deeply into the fluid than in the unstressed case. Overall, our results are consistent with the notion that in the absence of mechanical forcing a fluid that is heated and cooled from above cannot maintain a deep stratification or a strong sustained flow at high Rayleigh numbers, even if the interior flow is unsteady.

  19. Sitting and standing blood pressure measurements are not accurate for the diagnosis of orthostatic hypotension.

    LENUS (Irish Health Repository)

    Cooke, J

    2012-01-31

    INTRODUCTION: Orthostatic hypotension (OH) is associated with troublesome symptoms and increased mortality. It is treatable and deserving of accurate diagnosis. This can be time consuming. The current reference standard for its diagnosis is head-up tilt (HUT) testing with continuous beat-to-beat plethysmography. Our objective was to assess the accuracy of sit-stand testing with semi-automatic sphygmomanometry for the diagnosis of OH. DESIGN: Retrospective test of diagnostic accuracy. METHODS: This was a retrospective study performed using a database maintained by a busy syncope unit. HUT testing was performed using an automated tilt table with Finometer monitoring. A 3 min 70 degrees HUT was performed following 5 min supine. Sitting blood pressure (BP) was measured following 3 min rest. Standing BP was measured within 30 s of assuming the upright posture. The results of sit-stand testing were compared with HUT testing as a reference standard. Both tests happened within 5 min of each other and patients underwent no intervention between tests. RESULTS: From a total of 1452 consecutive HUTs, we identified 730 with pre-test measures of sitting and standing BP. The mean age of this group was 70.57 years (SD = 15.1), 62% were female. The sensitivity of sit-stand testing was calculated as 15.5%, specificity as 89.9%, positive predictive value as 61.7%, negative predictive value as 50.2% and the likelihood ratio as 1.6. The area under the Receiver Operator Curve was 0.564. CONCLUSION: We have demonstrated that sit-stand testing for OH has very low diagnostic accuracy. We recommend that the more time-consuming reference standard method of diagnosis be used if the condition is suspected.

  20. Does Courvoisier's sign stand the test of time?

    LENUS (Irish Health Repository)

    Murphy, K

    2012-11-01

    To investigate the validity of Courvoisier\\'s sign, in the age of cross-sectional imaging and image analysis software by objectively measuring gallbladder volumes at magnetic resonance cholangiopancreatography (MRCP) in patients with and without biliary obstruction and to assess whether gallbladder volume is more significantly increased in patients with gallstone-related rather than non-gallstone-related biliary obstruction.

  1. Building stable customer relationships that stand the test of time.

    Science.gov (United States)

    Murray, M; Hines, J D

    1996-05-01

    This article shows how Baldor Electric Company is using training to build a foundation for improving service in all areas of the business. It covers the background that led to Baldor Electric's decision to develop service training in-house, the steps that Baldor took in putting the course together, and the actual principles taught in the Baldor service course. The Baldor service course teaches basic principles that can be used by all employees to improve customer service, no matter what job they do.

  2. Structural mechanics of seed deterioration: Standing the test of time

    Science.gov (United States)

    Seeds die unexpectedly during storage and current understanding of seed quality and storage conditions does not allow reliable means to predict or prevent this critical problem. Chemical degradation of seed components likely occurs through oxidative damage, but the rate of these reactions is domina...

  3. Standing on a declining surface reduces transient prolonged standing induced low back pain development.

    Science.gov (United States)

    Gallagher, Kaitlin M; Callaghan, Jack P

    2016-09-01

    While alternating standing position on a sloped surface has proven successful at reducing low back pain during standing, the purpose of this study was to evaluate standing solely on a declining surface to isolate the influence of the postural change. Seventeen participants performed two 75-min prolonged standing occupational simulations- level ground and declining surface. Fifty-three percent of participants (9/17) were categorized as pain developers during the level ground standing condition. For these same pain developers, their average maximum pain scores were 58% lower during sloped standing. All participants showed greater hip flexion, trunk-to-thigh angle flexion, and posterior translation of the trunk center of gravity when standing on the sloped surface. These postural changes could cause the muscles crossing the hip posteriorly to increase passive stiffness and assist with stabilizing the pelvis. This study stresses the importance of hip kinematics, not just lumbar spine posture, in reducing prolonged standing induced low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Advance reproduction and other stand characteristics in Pennsylvania and French stands of northern red oak

    Science.gov (United States)

    Kim C. Steiner; Marc D. Abrams; Todd W. Bowersox

    1993-01-01

    The frequent scarcity of northern red oak (NRO) advance reproduction raises questions about its regeneration potential under prevailing stand conditions in eastern North America. In contrast, NRO plantations in France typically contain abundant advance reproduction. The purpose of this study was to document stand conditions in Pennsylvania (PA) and southwestern France...

  5. Model for multi-stand management based on structural attributes of individual stands

    Science.gov (United States)

    G.W. Miller; J. Sullivan

    1997-01-01

    A growing interest in managing forest ecosystems calls for decision models that take into account attribute goals for large forest areas while continuing to recognize the individual stand as a basic unit of forest management. A dynamic, nonlinear forest management model is described that schedules silvicultural treatments for individual stands that are linked by multi-...

  6. Horizontal oil well applications and oil recovery assessment. Volume 1: Success of horizontal well technology, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Deskins, W.G.; McDonald, W.J.; Knoll, R.G.; Springer, S.J.

    1995-03-01

    Horizontal technology has been applied in over 110 formations in the USA. Volume I of this study addresses the overall success of horizontal technology, especially in less-publicized formations, i.e., other than the Austin Chalk, Bakken, and Niobrara. Operators in the USA. and Canada were surveyed on a formation-by-formation basis by means of a questionnaire. Response data were received describing horizontal well projects in 58 formations in the USA. and 88 in Canada. Operators responses were analyzed for trends in technical and economic success based on lithology (clastics and carbonates) and resource type (light oil, heavy oil, and gas). The potential impact of horizontal technology on reserves was also estimated. A forecast of horizontal drilling activity over the next decade was developed.

  7. Reliability of standing weight-bearing (0.25T) MR imaging findings and positional changes in the lumbar spine

    DEFF Research Database (Denmark)

    Hansen, Bjarke B; Hansen, Philip; Christensen, Anders F

    2018-01-01

    OBJECTIVE: To test the reliability and absolute agreement of common degenerative findings in standing positional magnetic resonance imaging (pMRI). METHODS AND MATERIALS: Low back pain patients with and without sciatica were consecutively enrolled to undergo a supine and standing pMRI. Three...

  8. Disturbance From the Initial Harvest Implementing Uneven-Aged Silviculture in a Pine-Hardwood Stand in Southwestern Mississippi

    Science.gov (United States)

    Michael G. Shelton; Paul A. Murphy

    1999-01-01

    Logging disturbance is important in uneven-aged stands because harvests are frequent, merchantable trees are retained, and regeneration may be present. Logging disturbance was monitored during the establishment of a study testing the application of uneven-aged silvicufture in an irregularly aged, pine-hardwood stand. Disturbances were: (1) seedbed conditions...

  9. Radiation components of beech stands in southwest Germany

    Energy Technology Data Exchange (ETDEWEB)

    Holst, T.; Mayer, H. [Meteorological Inst., Univ. of Freiburg (Germany)

    2005-04-01

    Within the framework of an interdisciplinary project on the impact of climate and forest management on beech dominated deciduous forests, forest meteorological measurements are carried out within and above different beech stands (Fagus sylvatica L.) on opposite slopes of a narrow valley located in the Swabian Jura mountain range (south-west Germany). Referring to test plots on both slopes, the following cycles of radiation components are discussed: (1) Monthly mean values of transmission and extinction of global solar irradiance, photosynthetically active radiation as well as UV-A and UV-B radiation through the canopy, (2) diurnal courses of surface albedo {alpha}, net short-wave radiation K{sup *}, net long-wave radiation L{sup *} and net all-wave radiation Q{sup *} for a cloudless day in March (leafless period) and a cloudless day in July (fully-leaved period) above and below the canopy of different beech stands, and (3) monthly mean values of {alpha}, K{sup *}, L{sup *} and Q{sup *} for the same stand conditions as for (2). The results point out the combined impact on the investigated radiation components emanating from seasonally variable canopy density (quantified by the plant area index), exposure and sun elevation. (orig.)

  10. Modelling canopy fuel and forest stand variables and characterizing the influence of thinning in the stand structure using airborne LiDAR

    Directory of Open Access Journals (Sweden)

    A. Hevia

    2016-02-01

    Full Text Available Forest fires are a major threat in NW Spain. The importance and frequency of these events in the area suggests the need for fuel management programs to reduce the spread and severity of forest fires. Thinning treatments can contribute for fire risk reduction, because they cut off the horizontal continuity of forest fuels. Besides, it is necessary to conduct a fire risk management based on the knowledge of fuel allocation, since fire behaviour and fire spread study is dependent on the spatial factor. Therefore, mapping fuel for different silvicultural scenarios is essential. Modelling forest variables and forest structure parameters from LiDAR technology is the starting point for developing spatially explicit maps. This is essential in the generation of fuel maps since field measurements of canopy fuel variables is not feasible. In the present study, we evaluated the potential of LiDAR technology to estimate canopy fuel variables and other stand variables, as well as to identify structural differences between silvicultural managed and unmanaged P. pinaster Ait. stands. Independent variables (LiDAR metrics of greater explanatory significance were identified and regression analyses indicated strong relationships between those and field-derived variables (R2 varied between 0.86 and 0.97. Significant differences were found in some LiDAR metrics when compared thinned and unthinned stands. Results showed that LiDAR technology allows to model canopy fuel and stand variables with high precision in this species, and provides useful information for identifying areas with and without silvicultural management.

  11. Static standing, dynamic standing and spasticity in individuals with spinal cord injury.

    Science.gov (United States)

    Sadeghi, M; Mclvor, J; Finlayson, H; Sawatzky, B

    2016-05-01

    This was a cross-over efficacy study design. To determine spasticity differences between static and dynamic standing training in individuals with spinal cord injury (SCI). Vancouver, Canada. Ten individuals with SCI who could stand with or without bracing or supports participated in both dynamic and static standing training (one session each, 2 days apart) using a Segway. The primary outcome was spasticity as measured by Visual Analog Scale (VAS), Modified Ashworth Scale (MAS) and electromyography (EMG) of the quadriceps, hamstrings, adductors and gastrocnemius. There was no statistically detectable difference in spasticity between dynamic and static standing training in individuals with SCI as measured by VAS, MAS or EMG, although there was a trend towards decreased spasticity after the dynamic training. There is no significant difference in spasticity outcomes between static and dynamic standing training on a Segway for individuals with SCI. This research was funded by Natural Sciences and Engineering Research Council of Canada and International Collaboration on Repair Discoveries.

  12. ASSESSMENT OF STAND DENSITY AND GROWTH RATE OF ...

    African Journals Online (AJOL)

    ABIA

    Tectona grandis stands in the arboretum of the. Department of Forestry and Wildlife,. University of Uyo, have not been assessed for stand density and growth rates. Thus, there had been no data on the stand densities of these stands and the growth rates of the trees for rational decision making and sustainable management.

  13. Future directions in standing-wave photoemission

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Alexander X., E-mail: axgray@temple.edu

    2014-08-15

    Highlights: • Probing magnetic properties at the buried interface with SW-MCD. • Probing electronic structure at the buried interface with resonant SW-XPS and SW-HAXPES. • Probing momentum-resolved electronic structure at a buried interface with SWARPES. • Adding depth resolution to photoemission microscopy with standing-wave excitation. • Standing-wave localization, total reflection and waveguide effects. - Abstract: Over the past decade, standing-wave photoemission (SW-XPS) has evolved into a powerful and versatile non-destructive technique for probing element-specific electronic, magnetic, and structural properties of buried layers and interfaces with sub-nanometer depth resolution. In this article, I will discuss several promising future directions in this emergent field stemming from experimental and theoretical studies wherein SW-XPS is combined with other X-ray techniques, such as magnetic circular dichroism (MCD), hard X-ray photoemission spectroscopy (HAXPES), angle-resolved photoemission (ARPES), and photoemission microscopy (PEEM), adding extra dimensions to the measurement and thus widening the scope of scientific and technological questions accessible via the use of standing waves. I will further discuss examples of recently developed methods for X-ray standing-wave data analysis, which yield layer-resolved matrix-element-weighted densities of states at interfaces as well as Ångstrom-level changes in periodicity of synthetic superlattices. Finally, I will explore the possibility of localizing the standing waves near the surface and within a buried layer by the use of aperiodic superlattices, total reflection, and X-ray waveguide effects.

  14. Horizontal gene acquisitions by eukaryotes as drivers of adaptive evolution.

    Science.gov (United States)

    Schönknecht, Gerald; Weber, Andreas P M; Lercher, Martin J

    2014-01-01

    In contrast to vertical gene transfer from parent to offspring, horizontal (or lateral) gene transfer moves genetic information between different species. Bacteria and archaea often adapt through horizontal gene transfer. Recent analyses indicate that eukaryotic genomes, too, have acquired numerous genes via horizontal transfer from prokaryotes and other lineages. Based on this we raise the hypothesis that horizontally acquired genes may have contributed more to adaptive evolution of eukaryotes than previously assumed. Current candidate sets of horizontally acquired eukaryotic genes may just be the tip of an iceberg. We have recently shown that adaptation of the thermoacidophilic red alga Galdieria sulphuraria to its hot, acid, toxic-metal laden, volcanic environment was facilitated by the acquisition of numerous genes from extremophile bacteria and archaea. Other recently published examples of horizontal acquisitions involved in adaptation include ice-binding proteins in marine algae, enzymes for carotenoid biosynthesis in aphids, and genes involved in fungal metabolism. Editor's suggested further reading in BioEssays Jumping the fine LINE between species: Horizontal transfer of transposable elements in animals catalyses genome evolution Abstract. © 2014 WILEY Periodicals, Inc.

  15. Costs and benefits of vertical and horizontal transmission of dengue virus.

    Science.gov (United States)

    Ruiz-Guzmán, Gloria; Ramos-Castañeda, José; Hernández-Quintero, Angélica; Contreras-Garduño, Jorge

    2016-11-15

    Parasites can be transmitted vertically and/or horizontally, but the costs or benefits for the host of infection have only been tested after horizontal transmission. Here, we report for the first time, to our knowledge, the survival, reproduction and infection of Aedes aegypti during vertical and horizontal transmission of dengue virus 2 (DENV-2). Females infected horizontally produced more eggs, with a sex ratio skewed towards males, compared with uninfected controls. However, there was no significant difference in the number of emerging adults or in survival of mothers. In contrast, dengue-infected female offspring (vertical transmission) had a shorter lifespan but there were no significant differences in the number of eggs or sex ratio, compared with controls. Finally, the corroboration of infection revealed that virus infected about 11.5% and 8.8% of pools of mothers and of daughters, respectively. These results suggest that the mode of infection and the contact with the virus has no reproductive costs to female mosquitoes, which may explain why both types of transmission are evolutionarily maintained. In addition, we suggest that more attention should be paid to the male contribution to virus dissemination within and among populations and as reservoirs of the infection for human diseases. © 2016. Published by The Company of Biologists Ltd.

  16. Enhanced horizontal transfer of antibiotic resistance genes in freshwater microcosms induced by an ionic liquid.

    Directory of Open Access Journals (Sweden)

    Qing Wang

    Full Text Available The spread and propagation of antibiotic resistance genes (ARGs is a worldwide public health concern. Ionic liquids (ILs, considered as "environmentally friendly" replacements for industrial organic solvents, have been widely applied in modern industry. However, few data have been collected regarding the potential ecological and environmental risks of ILs, which are important for preparing for their potential discharge into the environment. In this paper, the IL 1-butyl-3-methylimidazolium hexafluorophosphate ([BMIm][PF6] (0.001-5.0 g/L was tested for its effects on facilitating ARGs horizontal transfer mediated by plasmid RP4 in freshwater microcosms. In the horizontal transfer microcosms, the transfer frequency of plasmid RP4 was significantly enhanced (60-fold higher than untreated groups by the IL [BMIm][PF6] (1.0 g/L. Meanwhile, two strains of opportunistic pathogen Acinetobacter spp. and Salmonella spp. were isolated among the transconjugants, illustrating plasmid RP4 mediated horizontal transfer of ARGs occurred in pathogen. This could increase the risk of ARGs dissemination to human pathogens and pose great threat to public health. The cause that [BMIm[PF6] enhanced the transfer frequency of plasmid RP4 was proposed by suppressed cell membrane barrier and enhanced cell membrane permeability, which was evidenced by flow cytometry (FCM. This is the first report that some ILs facilitate horizontal transfer of plasmid RP4 which is widely distributed in the environment and thus add the adverse effects of the environmental risk of ILs.

  17. Research and application on the horizontal tectonic stress influence on the stability of deep roadway

    Science.gov (United States)

    CAO, Jian-jun; YAO, Zhuang-zhuang

    2017-04-01

    According to the test result of ground stress of -817.0m Horizontal shaft station in Huainan mine area, the stress field distribution characteristic of mainly with horizontal tectonic stress was analyzed, the deep roadway surrounding rock deformation and failure regularity under the situation of the maximum horizontal stress and roadway axis in the different angle were studied by using the FLAC3D simulation software, and then specific way of supporting and its parameters were designed combined with the shaft station layout conditions. The result shows that: the roadway stability is relatively good when its tunnel axis the maximum horizontal stress direction within 30° angle, surrounding rock deformation and the plastic zone at the top and bottom are significantly increasing along with the angle increased from 30° to 90°, the major form of deep soft rock deformation and failure is the floor heave. According to the simulation results, the conditions under the layout condition of the shaft station roadway, support methods and support parameters have been designed and determined. The supporting method can be referenced by the similar mines.

  18. Phylogeny poorly predicts the utility of a challenging horizontally transferred gene in Methylobacterium strains.

    Science.gov (United States)

    Michener, Joshua K; Vuilleumier, Stéphane; Bringel, Françoise; Marx, Christopher J

    2014-06-01

    Horizontal gene transfer plays a crucial role in microbial evolution. While much is known about the mechanisms that determine whether physical DNA can be transferred into a new host, the factors determining the utility of the transferred genes are less clear. We have explored this issue using dichloromethane consumption in Methylobacterium strains. Methylobacterium extorquens DM4 expresses a dichloromethane dehalogenase (DcmA) that has been acquired through horizontal gene transfer and allows the strain to grow on dichloromethane as the sole carbon and energy source. We transferred the dcmA gene into six Methylobacterium strains that include both close and distant evolutionary relatives. The transconjugants varied in their ability to grow on dichloromethane, but their fitness on dichloromethane did not correlate with the phylogeny of the parental strains or with any single tested physiological factor. This work highlights an important limiting factor in horizontal gene transfer, namely, the capacity of the recipient strain to accommodate the stress and metabolic disruption resulting from the acquisition of a new enzyme or pathway. Understanding these limitations may help to rationalize historical examples of horizontal transfer and aid deliberate genetic transfers in biotechnology for metabolic engineering.

  19. Horizontal gene transfer is more frequent with increased heterotrophy and contributes to parasite adaptation

    Science.gov (United States)

    Yang, Zhenzhen; Zhang, Yeting; Wafula, Eric K.; Honaas, Loren A.; Ralph, Paula E.; Jones, Sam; Clarke, Christopher R.; Liu, Siming; Su, Chun; Zhang, Huiting; Altman, Naomi S.; Schuster, Stephan C.; Timko, Michael P.; Yoder, John I.; dePamphilis, Claude W.

    2016-01-01

    Horizontal gene transfer (HGT) is the transfer of genetic material across species boundaries and has been a driving force in prokaryotic evolution. HGT involving eukaryotes appears to be much less frequent, and the functional implications of HGT in eukaryotes are poorly understood. We test the hypothesis that parasitic plants, because of their intimate feeding contacts with host plant tissues, are especially prone to horizontal gene acquisition. We sought evidence of HGTs in transcriptomes of three parasitic members of Orobanchaceae, a plant family containing species spanning the full spectrum of parasitic capabilities, plus the free-living Lindenbergia. Following initial phylogenetic detection and an extensive validation procedure, 52 high-confidence horizontal transfer events were detected, often from lineages of known host plants and with an increasing number of HGT events in species with the greatest parasitic dependence. Analyses of intron sequences in putative donor and recipient lineages provide evidence for integration of genomic fragments far more often than retro-processed RNA sequences. Purifying selection predominates in functionally transferred sequences, with a small fraction of adaptively evolving sites. HGT-acquired genes are preferentially expressed in the haustorium—the organ of parasitic plants—and are strongly biased in predicted gene functions, suggesting that expression products of horizontally acquired genes are contributing to the unique adaptive feeding structure of parasitic plants. PMID:27791104

  20. Role of Vibrio cholerae exochitinase ChiA2 in horizontal gene transfer.

    Science.gov (United States)

    Mondal, Moumita; Chatterjee, Nabendu Sekhar

    2016-03-01

    Vibrio cholerae exochitinase ChiA2 plays a key role in acquisition of nutrients by chitin hydrolysis in the natural environment as well as in pathogenesis in the intestinal milieu. In this study we demonstrate the importance of ChiA2 in horizontal gene transfer in the natural environment. We found that the expression of ChiA2 and TfoX, the central regulator of V. cholerae horizontal gene transfer, varied with changes in environmental conditions. The activity of ChiA2 was also dependent on these conditions. In 3 different environmental conditions tested here, we observed that the supporting environmental condition for maximum expression and activity of ChiA2 was 20 °C, pH 5.5, and 100 mmol/L salinity in the presence of chitin. The same condition also induced TfoX expression and was favorable for horizontal gene transfer in V. cholerae. High-performance liquid chromatography analysis showed that ChiA2 released a significant amount of (GlcNAc)2 from chitin hydrolysis under the favorable condition. We hypothesized that under the favorable environmental condition, ChiA2 was upregulated and maximally active to produce a significant amount of (GlcNAc)2 from chitin. The same environmental condition also induced tfoX expression, followed by its translational activation by the (GlcNAc)2 produced, leading to efficient horizontal gene transfer.