WorldWideScience

Sample records for home monitoring system

  1. System Security And Monitoring On Smart Home Using Android

    Science.gov (United States)

    Romadhon, A. S.

    2018-01-01

    Home security system is needed for homeowners who have a lot of activities, as a result, they often leave the house without locking the door and even leave the house in a state of lights that are not lit. In order to overcome this case, a system that can control and can monitor the state of the various devices contained in the house or smart home system is urgently required. The working principle of this smart home using android is when the homeowner sends a certain command using android, the command will be forwarded to the microcontroller and then it will be executed based on the parameters that have been determined. For example, it can turn off and on the light using android app. In this study, testing was conducted to a smart home prototype which is equipped with light bulbs, odour sensors, heat sensors, ultrasonic sensors, LDR, buzzer and camera. The test results indicate that the application has been able to control all the sensors of home appliances well.

  2. Sensor network infrastructure for a home care monitoring system.

    Science.gov (United States)

    Palumbo, Filippo; Ullberg, Jonas; Stimec, Ales; Furfari, Francesco; Karlsson, Lars; Coradeschi, Silvia

    2014-02-25

    This paper presents the sensor network infrastructure for a home care system that allows long-term monitoring of physiological data and everyday activities. The aim of the proposed system is to allow the elderly to live longer in their home without compromising safety and ensuring the detection of health problems. The system offers the possibility of a virtual visit via a teleoperated robot. During the visit, physiological data and activities occurring during a period of time can be discussed. These data are collected from physiological sensors (e.g., temperature, blood pressure, glucose) and environmental sensors (e.g., motion, bed/chair occupancy, electrical usage). The system can also give alarms if sudden problems occur, like a fall, and warnings based on more long-term trends, such as the deterioration of health being detected. It has been implemented and tested in a test environment and has been deployed in six real homes for a year-long evaluation. The key contribution of the paper is the presentation of an implemented system for ambient assisted living (AAL) tested in a real environment, combining the acquisition of sensor data, a flexible and adaptable middleware compliant with the OSGistandard and a context recognition application. The system has been developed in a European project called GiraffPlus.

  3. Monitoring Quality Across Home Visiting Models: A Field Test of Michigan's Home Visiting Quality Assurance System.

    Science.gov (United States)

    Heany, Julia; Torres, Jennifer; Zagar, Cynthia; Kostelec, Tiffany

    2018-06-05

    Introduction In order to achieve the positive outcomes with parents and children demonstrated by many home visiting models, home visiting services must be well implemented. The Michigan Home Visiting Initiative developed a tool and procedure for monitoring implementation quality across models referred to as Michigan's Home Visiting Quality Assurance System (MHVQAS). This study field tested the MHVQAS. This article focuses on one of the study's evaluation questions: Can the MHVQAS be applied across models? Methods Eight local implementing agencies (LIAs) from four home visiting models (Healthy Families America, Early Head Start-Home Based, Parents as Teachers, Maternal Infant Health Program) and five reviewers participated in the study by completing site visits, tracking their time and costs, and completing surveys about the process. LIAs also submitted their most recent review by their model developer. The researchers conducted participant observation of the review process. Results Ratings on the MHVQAS were not significantly different between models. There were some differences in interrater reliability and perceived reliability between models. There were no significant differences between models in perceived validity, satisfaction with the review process, or cost to participate. Observational data suggested that cross-model applicability could be improved by assisting sites in relating the requirements of the tool to the specifics of their model. Discussion The MHVQAS shows promise as a tool and process to monitor implementation quality of home visiting services across models. The results of the study will be used to make improvements before the MHVQAS is used in practice.

  4. A Remote Health Monitoring System for the Elderly Based on Smart Home Gateway

    OpenAIRE

    Guan, Kai; Shao, Minggang; Wu, Shuicai

    2017-01-01

    This paper proposed a remote health monitoring system for the elderly based on smart home gateway. The proposed system consists of three parts: the smart clothing, the smart home gateway, and the health care server. The smart clothing collects the elderly's electrocardiogram (ECG) and motion signals. The home gateway is used for data transmission. The health care server provides services of data storage and user information management; it is constructed on the Windows-Apache-MySQL-PHP (WAMP) ...

  5. Security And Privacy Issues in Health Monitoring Systems: eCare@Home Case Study

    DEFF Research Database (Denmark)

    Wearing, Thomas; Dragoni, Nicola

    2016-01-01

    Automated systems for monitoring elderly people in their home are becoming more and more common. Indeed, an increasing number of home sensor networks for healthcare can be found in the recent literature, indicating a clear research direction in smart homes for health-care. Although the huge amount...... of sensitive data these systems deal with and expose to the external world, security and privacy issues are surpris-ingly not taken into consideration. The aim of this paper is to raise some key security and privacy issues that home health monitor systems should face with. The analysis is based on a real world...... monitoring sensor network for healthcare built in the context of the eCare@Home project....

  6. An Integrated Patient Information and In-Home Health Monitoring System Using Smartphones and Web Services.

    Science.gov (United States)

    Sorwar, Golam; Ali, Mortuza; Islam, Md Kamrul; Miah, Mohammad Selim

    2016-01-01

    Modern healthcare systems are undergoing a paradigm shift from in-hospital care to in-home monitoring, leveraging the emerging technologies in the area of bio-sensing, wireless communication, mobile computing, and artificial intelligence. In-home monitoring promises to significantly reduce healthcare spending by preventing unnecessary hospital admissions and visits to healthcare professionals. Most of the in-home monitoring systems, proposed in the literature, focus on monitoring a set of specific vital signs. However, from the perspective of caregivers it is infeasible to maintain a collection of specialized monitoring systems. In this paper, we view the problem of in-home monitoring from the perspective of caregivers and present a framework that supports various monitoring capabilities while making the complexity transparent to the end users. The essential idea of the framework is to define a 'general purpose architecture' where the system specifies a particular protocol for communication and makes it public. Then any bio-sensing system can communicate with the system as long as it conforms to the protocol. We then argue that as the system grows in terms of number of patients and bio-sensing systems, artificial intelligence technologies need to be employed for patients' risk assessment, prioritization, and recommendation. Finally, we present an initial prototype of the system designed according to the proposed framework.

  7. A System for Monitoring Stroke Patients in a Home Environment

    NARCIS (Netherlands)

    Klaassen, Bart; van Beijnum, Bernhard J.F.; Weusthof, Marcel H.H.; Hofs, D.H.W.; van Meulen, Fokke; Luinge, Hendrik J.; Lorussi, Frederico; Hermens, Hermanus J.; Veltink, Petrus H.

    2014-01-01

    Currently, the changes of functional capacity and performance of stroke patients after returning home from a rehabilitation hospital is unknown for a physician, having no objective information about the intensity and quality of a patient's daily-life activities. Therefore, there is a need to develop

  8. A new system for continuous and remote monitoring of patients receiving home mechanical ventilation.

    Science.gov (United States)

    Battista, L

    2016-09-01

    Home mechanical ventilation is the treatment of patients with respiratory failure or insufficiency by means of a mechanical ventilator at a patient's home. In order to allow remote patient monitoring, several tele-monitoring systems have been introduced in the last few years. However, most of them usually do not allow real-time services, as they have their own proprietary communication protocol implemented and some ventilation parameters are not always measured. Moreover, they monitor only some breaths during the whole day, despite the fact that a patient's respiratory state may change continuously during the day. In order to reduce the above drawbacks, this work reports the development of a novel remote monitoring system for long-term, home-based ventilation therapy; the proposed system allows for continuous monitoring of the main physical quantities involved during home-care ventilation (e.g., differential pressure, volume, and air flow rate) and is developed in order to allow observations of different remote therapy units located in different places of a city, region, or country. The developed remote patient monitoring system is able to detect various clinical events (e.g., events of tube disconnection and sleep apnea events) and has been successfully tested by means of experimental tests carried out with pulmonary ventilators typically used to support sick patients.

  9. A Remote Health Monitoring System for the Elderly Based on Smart Home Gateway

    Science.gov (United States)

    Shao, Minggang

    2017-01-01

    This paper proposed a remote health monitoring system for the elderly based on smart home gateway. The proposed system consists of three parts: the smart clothing, the smart home gateway, and the health care server. The smart clothing collects the elderly's electrocardiogram (ECG) and motion signals. The home gateway is used for data transmission. The health care server provides services of data storage and user information management; it is constructed on the Windows-Apache-MySQL-PHP (WAMP) platform and is tested on the Ali Cloud platform. To resolve the issues of data overload and network congestion of the home gateway, an ECG compression algorithm is applied. System demonstration shows that the ECG signals and motion signals of the elderly can be monitored. Evaluation of the compression algorithm shows that it has a high compression ratio and low distortion and consumes little time, which is suitable for home gateways. The proposed system has good scalability, and it is simple to operate. It has the potential to provide long-term and continuous home health monitoring services for the elderly. PMID:29204258

  10. A Remote Health Monitoring System for the Elderly Based on Smart Home Gateway

    Directory of Open Access Journals (Sweden)

    Kai Guan

    2017-01-01

    Full Text Available This paper proposed a remote health monitoring system for the elderly based on smart home gateway. The proposed system consists of three parts: the smart clothing, the smart home gateway, and the health care server. The smart clothing collects the elderly’s electrocardiogram (ECG and motion signals. The home gateway is used for data transmission. The health care server provides services of data storage and user information management; it is constructed on the Windows-Apache-MySQL-PHP (WAMP platform and is tested on the Ali Cloud platform. To resolve the issues of data overload and network congestion of the home gateway, an ECG compression algorithm is applied. System demonstration shows that the ECG signals and motion signals of the elderly can be monitored. Evaluation of the compression algorithm shows that it has a high compression ratio and low distortion and consumes little time, which is suitable for home gateways. The proposed system has good scalability, and it is simple to operate. It has the potential to provide long-term and continuous home health monitoring services for the elderly.

  11. A Remote Health Monitoring System for the Elderly Based on Smart Home Gateway.

    Science.gov (United States)

    Guan, Kai; Shao, Minggang; Wu, Shuicai

    2017-01-01

    This paper proposed a remote health monitoring system for the elderly based on smart home gateway. The proposed system consists of three parts: the smart clothing, the smart home gateway, and the health care server. The smart clothing collects the elderly's electrocardiogram (ECG) and motion signals. The home gateway is used for data transmission. The health care server provides services of data storage and user information management; it is constructed on the Windows-Apache-MySQL-PHP (WAMP) platform and is tested on the Ali Cloud platform. To resolve the issues of data overload and network congestion of the home gateway, an ECG compression algorithm is applied. System demonstration shows that the ECG signals and motion signals of the elderly can be monitored. Evaluation of the compression algorithm shows that it has a high compression ratio and low distortion and consumes little time, which is suitable for home gateways. The proposed system has good scalability, and it is simple to operate. It has the potential to provide long-term and continuous home health monitoring services for the elderly.

  12. Heart failure - home monitoring

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000113.htm Heart failure - home monitoring To use the sharing features on ... your high blood pressure Fast food tips Heart failure - discharge Heart failure - fluids and diuretics Heart failure - what to ...

  13. Integrity mechanism for eHealth tele-monitoring system in smart home environment.

    Science.gov (United States)

    Mantas, Georgios; Lymberopoulos, Dimitrios; Komninos, Nikos

    2009-01-01

    During the past few years, a lot of effort has been invested in research and development of eHealth tele-monitoring systems that will provide many benefits for healthcare delivery from the healthcare provider to the patient's home. However, there is a plethora of security requirements in eHealth tele-monitoring systems. Data integrity of the transferred medical data is one of the most important security requirements that should be satisfied in these systems, since medical information is extremely sensitive information, and even sometimes life threatening information. In this paper, we present a data integrity mechanism for eHealth tele-monitoring system that operates in a smart home environment. Agent technology is applied to achieve data integrity with the use of cryptographic smart cards. Furthermore, the overall security infrastructure and its various components are described.

  14. SymptomCare@Home: Developing an Integrated Symptom Monitoring and Management System for Outpatients Receiving Chemotherapy.

    Science.gov (United States)

    Beck, Susan L; Eaton, Linda H; Echeverria, Christina; Mooney, Kathi H

    2017-10-01

    SymptomCare@Home, an integrated symptom monitoring and management system, was designed as part of randomized clinical trials to help patients with cancer who receive chemotherapy in ambulatory clinics and often experience significant symptoms at home. An iterative design process was informed by chronic disease management theory and features of assessment and clinical decision support systems used in other diseases. Key stakeholders participated in the design process: nurse scientists, clinical experts, bioinformatics experts, and computer programmers. Especially important was input from end users, patients, and nurse practitioners participating in a series of studies testing the system. The system includes both a patient and clinician interface and fully integrates two electronic subsystems: a telephone computer-linked interactive voice response system and a Web-based Decision Support-Symptom Management System. Key features include (1) daily symptom monitoring, (2) self-management coaching, (3) alerting, and (4) nurse practitioner follow-up. The nurse practitioner is distinctively positioned to provide assessment, education, support, and pharmacologic and nonpharmacologic interventions to intensify management of poorly controlled symptoms at home. SymptomCare@Home is a model for providing telehealth. The system facilitates using evidence-based guidelines as part of a comprehensive symptom management approach. The design process and system features can be applied to other diseases and conditions.

  15. Home apnea monitor use - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000755.htm Home apnea monitor use - infants To use the sharing ... portable. Why is an Apnea Monitor Used at Home? A monitor may be needed when: Your baby ...

  16. Development of a user-friendly, low-cost home energy monitoring and recording system

    International Nuclear Information System (INIS)

    Fletcher, James; Malalasekera, Weeratunge

    2016-01-01

    This paper reports research undertaken to develop a user-friendly home energy monitoring system which is capable of collecting, processing and displaying detailed usage data. The system allows users to monitor power usage and switch their electronic appliances remotely, using any web enabled device, including computers, phones and tablets. The system aims to raise awareness of consumer energy use by gathering data about usage habits, and displaying this information to support consumers when selecting energy tariffs or new appliances. To achieve these aims, bespoke electrical hardware, or ‘nodes’, have been designed and built to monitor power usage, switch devices on and off, and communicate via a Wi-Fi connection, with bespoke software, the ‘server’. The server hosts a webpage which allows users to see a real-time overview of how power is being used in the home as well as allowing scheduled tasks and triggered tasks (which respond to events) to be programmed. The system takes advantage of well standardised networking specifications, such as Wi-Fi and TCP, allowing access from within the home, or remotely through the internet. The server runs under Debian Linux on a Raspberry Pi computer and is written in Python, HTML and JavaScript. The server includes advanced functionality, such as device recognition which allows users to individually monitor several devices that share a single node. The openPicus Flyport is used to provide Wi-Fi connectivity and programmable logic control to nodes. The Flyport is programmed with code compiled from C. - Highlights: • The system is capable of collecting, processing and displaying detailed usage data. • The system is built using commonly available components and software. • Nodes in this system can communicate via a Wi-Fi connection with a server. • The data saved in the server can be used in smart grid applications.

  17. WiSPH: A Wireless Sensor Network-Based Home Care Monitoring System

    Directory of Open Access Journals (Sweden)

    Pedro Magaña-Espinoza

    2014-04-01

    Full Text Available This paper presents a system based on WSN technology capable of monitoring heart rate and the rate of motion of seniors within their homes. The system is capable of remotely alerting specialists, caretakers or family members via a smartphone of rapid physiological changes due to falls, tachycardia or bradycardia. This work was carried out using our workgroup’s WiSe platform, which we previously developed for use in WSNs. The proposed WSN architecture is flexible, allowing for greater scalability to better allow event-based monitoring. The architecture also provides security mechanisms to assure that the monitored and/or stored data can only be accessed by authorized individuals or devices. The aforementioned characteristics provide the network versatility and solidity required for use in health applications.

  18. WiSPH: a wireless sensor network-based home care monitoring system.

    Science.gov (United States)

    Magaña-Espinoza, Pedro; Aquino-Santos, Raúl; Cárdenas-Benítez, Néstor; Aguilar-Velasco, José; Buenrostro-Segura, César; Edwards-Block, Arthur; Medina-Cass, Aldo

    2014-04-22

    This paper presents a system based on WSN technology capable of monitoring heart rate and the rate of motion of seniors within their homes. The system is capable of remotely alerting specialists, caretakers or family members via a smartphone of rapid physiological changes due to falls, tachycardia or bradycardia. This work was carried out using our workgroup's WiSe platform, which we previously developed for use in WSNs. The proposed WSN architecture is flexible, allowing for greater scalability to better allow event-based monitoring. The architecture also provides security mechanisms to assure that the monitored and/or stored data can only be accessed by authorized individuals or devices. The aforementioned characteristics provide the network versatility and solidity required for use in health applications.

  19. Development of Home-Based Sleep Monitoring System for Obstructive Sleep Apnea.

    Science.gov (United States)

    Wu, Peirong; Chen, Guan-Ting; Cui, Yanyan; Li, Jin-Wei; Kuo, Terry B J; Chang, Polun

    2017-01-01

    Obstructive Sleep Apnea (OSA) has been proven to increase the risk of high blood pressure, heart attack, stroke, obesity, and diabetes. If people would like to know whether they are suffering from this sleep disorder, they need to go to particular hospital with which a sleep center that could perform polysomnography (PSG); however, for most people, this is not convenient. Consequently, the goal of this study is to develop a convenient, lower priced, and easy-to-use home-based sleep monitoring system. The researchers have developed the "Sleep Healthcare Management System" for OSA patients and healthcare providers. It combines smartphone and wearable devices that can perform real-time sleep monitoring. Healthcare providers could apply their professional knowledge to provide customized feedback via a web application. When the patient is diagnosed with an abnormal sleep health condition, healthcare providers may be able to provide appropriate and timely care.

  20. Blood pressure monitors for home

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007482.htm Blood pressure monitors for home To use the sharing features ... may ask you to keep track of your blood pressure at home. To do this, you will need ...

  1. A Novel and Intelligent Home Monitoring System for Care Support of Elders with Cognitive Impairment.

    Science.gov (United States)

    Lazarou, Ioulietta; Karakostas, Anastasios; Stavropoulos, Thanos G; Tsompanidis, Theodoros; Meditskos, Georgios; Kompatsiaris, Ioannis; Tsolaki, Magda

    2016-10-18

    Assistive technology, in the form of a smart home environment, is employed to support people with dementia. To propose a system for continuous and objective remote monitoring of problematic daily living activity areas and design personalized interventions based on system feedback and clinical observations for improving cognitive function and health-related quality of life. The assistive technology of the proposed system, including wearable, sleep, object motion, presence, and utility usage sensors, was methodically deployed at four different home installations of people with cognitive impairment. Detection of sleep patterns, physical activity, and activities of daily living, based on the collected sensor data and analytics, was available at all times through comprehensive data visualization solutions. Combined with clinical observation, targeted psychosocial interventions were introduced to enhance the participants' quality of life and improve their cognitive functions and daily functionality. Meanwhile, participants and their caregivers were able to visualize a reduced set of information tailored to their needs. Overall, paired-sample t-test analysis of monitored qualities revealed improvement for all participants in neuropsychological assessment. Moreover, improvement was detected from the beginning to the end of the trial, in physical condition and in the domains of sleep. Detecting abnormalities via the system, for example in sleep quality, such as REM sleep, has proved to be critical to assess current status, drive interventions, and evaluate improvements in a reliable manner. It has been proved that the proposed system is suitable to support clinicians to reliably drive and evaluate clinical interventions toward quality of life improvement of people with cognitive impairment.

  2. Smartphone home monitoring of ECG

    Science.gov (United States)

    Szu, Harold; Hsu, Charles; Moon, Gyu; Landa, Joseph; Nakajima, Hiroshi; Hata, Yutaka

    2012-06-01

    A system of ambulatory, halter, electrocardiography (ECG) monitoring system has already been commercially available for recording and transmitting heartbeats data by the Internet. However, it enjoys the confidence with a reservation and thus a limited market penetration, our system was targeting at aging global villagers having an increasingly biomedical wellness (BMW) homecare needs, not hospital related BMI (biomedical illness). It was designed within SWaP-C (Size, Weight, and Power, Cost) using 3 innovative modules: (i) Smart Electrode (lowpower mixed signal embedded with modern compressive sensing and nanotechnology to improve the electrodes' contact impedance); (ii) Learnable Database (in terms of adaptive wavelets transform QRST feature extraction, Sequential Query Relational database allowing home care monitoring retrievable Aided Target Recognition); (iii) Smartphone (touch screen interface, powerful computation capability, caretaker reporting with GPI, ID, and patient panic button for programmable emergence procedure). It can provide a supplementary home screening system for the post or the pre-diagnosis care at home with a build-in database searchable with the time, the place, and the degree of urgency happened, using in-situ screening.

  3. An IoT System for Remote Monitoring of Patients at Home

    Directory of Open Access Journals (Sweden)

    KeeHyun Park

    2017-03-01

    Full Text Available Application areas that utilize the concept of IoT can be broadened to healthcare or remote monitoring areas. In this paper, a remote monitoring system for patients at home in IoT environments is proposed, constructed, and evaluated through several experiments. To make it operable in IoT environments, a protocol conversion scheme between ISO/IEEE 11073 protocol and oneM2M protocol, and a Multiclass Q-learning scheduling algorithm based on the urgency of biomedical data delivery to medical staff are proposed. In addition, for the sake of patients’ privacy, two security schemes are proposed—the separate storage scheme of data in parts and the Buddy-ACK authorization scheme. The experiment on the constructed system showed that the system worked well and the Multiclass Q-learning scheduling algorithm performs better than the Multiclass Based Dynamic Priority scheduling algorithm. We also found that the throughputs of the Multiclass Q-learning scheduling algorithm increase almost linearly as the measurement time increases, whereas the throughputs of the Multiclass Based Dynamic Priority algorithm increase with decreases in the increasing ratio.

  4. A mobile cloud-based Parkinson's disease assessment system for home-based monitoring.

    Science.gov (United States)

    Pan, Di; Dhall, Rohit; Lieberman, Abraham; Petitti, Diana B

    2015-03-26

    Parkinson's disease (PD) is the most prevalent movement disorder of the central nervous system, and affects more than 6.3 million people in the world. The characteristic motor features include tremor, bradykinesia, rigidity, and impaired postural stability. Current therapy based on augmentation or replacement of dopamine is designed to improve patients' motor performance but often leads to levodopa-induced adverse effects, such as dyskinesia and motor fluctuation. Clinicians must regularly monitor patients in order to identify these effects and other declines in motor function as soon as possible. Current clinical assessment for Parkinson's is subjective and mostly conducted by brief observations made during patient visits. Changes in patients' motor function between visits are hard to track and clinicians are not able to make the most informed decisions about the course of therapy without frequent visits. Frequent clinic visits increase the physical and economic burden on patients and their families. In this project, we sought to design, develop, and evaluate a prototype mobile cloud-based mHealth app, "PD Dr", which collects quantitative and objective information about PD and would enable home-based assessment and monitoring of major PD symptoms. We designed and developed a mobile app on the Android platform to collect PD-related motion data using the smartphone 3D accelerometer and to send the data to a cloud service for storage, data processing, and PD symptoms severity estimation. To evaluate this system, data from the system were collected from 40 patients with PD and compared with experts' rating on standardized rating scales. The evaluation showed that PD Dr could effectively capture important motion features that differentiate PD severity and identify critical symptoms. For hand resting tremor detection, the sensitivity was .77 and accuracy was .82. For gait difficulty detection, the sensitivity was .89 and accuracy was .81. In PD severity estimation, the

  5. A Wireless Posture Monitoring System for Personalized Home-Based Rehabilitation

    Directory of Open Access Journals (Sweden)

    Pedro Macedo

    2015-06-01

    Full Text Available We live in an aging society, an issue that will be exacerbated in the coming decades, due to low birth rates and increasing life expectancy. With the decline in physical and cognitive functions with age, it is of the utmost importance to maintain regular physical activity, in order to preserve an individual’s mobility, motor capabilities and coordination. Within this context, this paper describes the development of a wireless sensor network and its application in a human motion capture system based on wearable inertial and magnetic sensors. The goal is to enable, through continuous real- time monitoring, the creation of a personalized home-based rehabilitation system for the elderly population and/or injured people. Within this system, the user can benefit from an assisted mode, in which their movements can be compared to a reference motion model of the same movements, resulting in visual feedback alerts given by the application. This motion model can be created previously, in a ‘learning phase’, under supervision of a caregiver.

  6. Development of a fully automated network system for long-term health-care monitoring at home.

    Science.gov (United States)

    Motoi, K; Kubota, S; Ikarashi, A; Nogawa, M; Tanaka, S; Nemoto, T; Yamakoshi, K

    2007-01-01

    Daily monitoring of health condition at home is very important not only as an effective scheme for early diagnosis and treatment of cardiovascular and other diseases, but also for prevention and control of such diseases. From this point of view, we have developed a prototype room for fully automated monitoring of various vital signs. From the results of preliminary experiments using this room, it was confirmed that (1) ECG and respiration during bathing, (2) excretion weight and blood pressure, and (3) respiration and cardiac beat during sleep could be monitored with reasonable accuracy by the sensor system installed in bathtub, toilet and bed, respectively.

  7. Home-made temperature monitoring system from four-channel K-type thermocouples via internet of thing technology platform

    Science.gov (United States)

    Detmod, Thitaporn; Özmen, Yiǧiter; Songkaitiwong, Kittiphot; Saenyot, Khanuengchat; Locharoenrat, Kitsakorn; Lekchaum, Sarai

    2018-06-01

    This paper is aimed to design and construct the home-made temperature monitoring system from four-channel K-type thermocouples in order to improve the temperature measurement based on standard evaluation measurements guidance. The temperature monitoring system was capable to record the temperature on SD card and to display the realtime temperature on Internet of Thing Technology platform. The temperature monitoring system was tested in terms of the temperature measurement accuracy and delay response time. It was found that a standard deviation was acceptable as compared to the Instrument Society of America. The response time of the microcontroller to SD card was 2 sec faster than that of the microcontroller to Thingspeak.

  8. A Context-Aware System Infrastructure for Monitoring Activities of Daily Living in Smart Home

    Directory of Open Access Journals (Sweden)

    Qin Ni

    2016-01-01

    Full Text Available We propose a three-layered context-aware architecture for monitoring activities of daily life in smart home. This architecture provides for the inclusion of functionalities that range from low-level data collection to high-level context knowledge extraction. We have also devised an upper-level ontology to model the context in which the activities take place. This enables having a common activity-related context representation, on which to infer and share knowledge. Furthermore, we have begun to implement a platform that realizes our architecture and ontology, making use of Microsoft’s Lab of Things (LoT platform, being the preliminary results on this task also described in the paper.

  9. Personalized Monitoring and Assistive Systems: Case Study of Efficient Home Solutions.

    Science.gov (United States)

    Lhotska, Lenka; Doležal, Jaromír; Adolf, Jindřich; Potůček, Jiří; Křížek, Miroslav; Chbani, Baha

    2018-01-01

    The rapid emergence and proliferation of connected medical devices and their application in healthcare are already part of the Healthcare Internet of Things (IoT) - as this area started to be named. Their true impact on patient care and other aspects of healthcare remains to be seen and is highly dependent on the quality and relevancy of the data acquired. There is also the trend of application of IoT in telemedicine and home care environment. Currently many research groups focus on design and development of various solutions that can assist elderly and handicapped people in their home environment. However, many of these solutions are sophisticated and require advanced users that are able to control the device, handle error states and exceptions. They are frequently using expensive technologies that are good for laboratory environment but they are not affordable for many elderly or handicapped persons. In the paper we will analyze the current situation, present identified needs of elderly population and propose potential solutions. On a case study of efficient home solution of a personalized and assistive system we will show possibilities of technologically simple solutions using off-the-shelf devices and elements.

  10. A posture recognition based fall detection system for monitoring an elderly person in a smart home environment.

    Science.gov (United States)

    Yu, Miao; Rhuma, Adel; Naqvi, Syed Mohsen; Wang, Liang; Chambers, Jonathon

    2012-11-01

    We propose a novel computer vision based fall detection system for monitoring an elderly person in a home care application. Background subtraction is applied to extract the foreground human body and the result is improved by using certain post-processing. Information from ellipse fitting and a projection histogram along the axes of the ellipse are used as the features for distinguishing different postures of the human. These features are then fed into a directed acyclic graph support vector machine (DAGSVM) for posture classification, the result of which is then combined with derived floor information to detect a fall. From a dataset of 15 people, we show that our fall detection system can achieve a high fall detection rate (97.08%) and a very low false detection rate (0.8%) in a simulated home environment.

  11. A new kind of universal smart home security safety monitoring system

    Science.gov (United States)

    Li, Biqing; Li, Zhao

    2018-04-01

    With the current level of social development, improved quality of life, existence and security issues of law and order has become an important issue. This graduation project adopts the form of wireless transmission, to STC89C52 microcontroller as the host control human infrared induction anti-theft monitoring system. The system mainly consists of main control circuit, power supply circuit, activities of the human body detection module, sound and light alarm circuit, record and display circuit. The main function is to achieve exploration activities on the human body, then the information is transmitted to the control panel, according to the system microcontroller program control sound and light alarm circuit, while recording the alarm location and time, and always check the record as required, and ultimately achieve the purpose of monitoring. The advantage of using pyroelectric infrared sensor can be installed in a hidden place, not easy to find, and low cost, good detection results, and has broad prospects for development.

  12. ESUMS: a mobile system for continuous home monitoring of rehabilitation patients.

    Science.gov (United States)

    Strisland, Frode; Svagård, Ingrid; Seeberg, Trine M; Mathisen, Bjørn Magnus; Vedum, Jon; Austad, Hanne O; Liverud, Anders E; Kofod-Petersen, Anders; Bendixen, Ole Christian

    2013-01-01

    The pressure on the healthcare services is building up for several reasons. The ageing population trend, the increase in life-style related disease prevalence, as well as the increased treatment capabilities with associated general expectation all add pressure. The use of ambient healthcare technologies can alleviate the situation by enabling time and cost-efficient monitoring and follow-up of patients discharged from hospital care. We report on an ambulatory system developed for monitoring of physical rehabilitation patients. The system consists of a wearable multisensor monitoring device; a mobile phone with client application aggregating the data collected; a service-oriented-architecture based server solution; and a PC application facilitating patient follow-up by their health professional carers. The system has been tested and verified for accuracy in controlled environment trials on healthy volunteers, and also been usability tested by 5 congestive heart failure patients and their nurses. This investigation indicated that patients were able to use the system, and that nurses got an improved basis for patient follow-up.

  13. A Web site-based reporting system for monitoring home treatment during oral immunotherapy for food allergy.

    Science.gov (United States)

    Nachshon, Liat; Goldberg, Michael R; Elizur, Arnon; Levy, Michael B; Schwartz, Naama; Katz, Yitzhak

    2015-06-01

    Reactions during the home treatment phase of oral immunotherapy (OIT) are not uncommon. An ongoing accurate reporting of home treatment outcomes is crucial for the safety and success of OIT. Previous reports have shown that as few as 20% of patients are truly compliant with paper-based diaries. To develop a Web site-based electronic reporting system (web-RS) for monitoring home treatment during OIT for food allergy. A web-RS was developed and incorporated a thorough questionnaire querying for pertinent data including the dose(s) consumed, occurrence and details of adverse reactions, treatment(s), and relevant potential exacerbating factors. All patients enrolled in milk, peanut, or egg OIT programs for at least 4 weeks from November 2012 through January 2014 were introduced to web-RS (n = 157). Successful reporting through web-RS was defined by consecutive reporting during the first home treatment phase (24 days) after its introduction. Comparisons were made with a previous group of OIT-treated patients (n = 100) who reported by E-mail. Successful reporting was achieved by 142 of 157 patients (90.44%) in contrast to a 75% success rate with E-mail (P = .0009). The odds for successful reporting using web-RS were 3.1 (95% confidence interval 1.6-6.3) times higher compared with using E-mail. Mild reactions were reported more frequently with web-RS (P = .0032). Patient reports were constantly available in real time for medical staff review. No complaints regarding web-RS feasibility were reported. One risk factor for failure to use web-RS was a patient's prior successful OIT experience without using web-RS (P = .012). A web-RS can be a powerful tool for improving OIT safety by achieving a high level of patient cooperation in reporting home treatment results. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  14. Telemedical systems for home monitoring of patients with chronic conditions in rural environment

    Directory of Open Access Journals (Sweden)

    Marcin Maciejewski

    2014-03-01

    Full Text Available This paper describes the requirements and possible implementations of a telemedical system. The idea of remote patient monitoring is a point of interest for researchers in Poland, and is also in high demand in fields such as diabetology, cardiology, and geriatrics, among others. Aging society, medical care costs and many other factors make remote patient care a promising idea for the future. For each and every condition, a specialized type of sensor must be used to allow specific measurements to be performed. Moreover, a local data storage and communication device must be provided for the sensor to be able to relay data to the station. A smart phone can be used perform such tasks. By implementing such remote diagnostic systems it is possible to collect, process, store and present vital medical data that can be used immediately to perform diagnosis, or later as reference for expert systems. The ‘Borboleta’ and ‘SaguiSaúde’ systems already implemented can serve as a base for system analysis. The systems provide necessary functions and can be used as reference. Many factors contribute to the success of the telemedical system, such as ease of access, scalability, safety, platform independence, and many others. For easier implementation and clarity, the system should be divided into independent layers, which will also make it easier to modify and integrate into other medical systems. Making the system easy to use for patients, medical staff, administrators and data managers makes the task of system design especially challenging. One must decide which information is necessary for each type of user and provide them clearly and in an orderly fashion.

  15. An intelligent knowledge-based and customizable home care system framework with ubiquitous patient monitoring and alerting techniques.

    Science.gov (United States)

    Chen, Yen-Lin; Chiang, Hsin-Han; Yu, Chao-Wei; Chiang, Chuan-Yen; Liu, Chuan-Ming; Wang, Jenq-Haur

    2012-01-01

    This study develops and integrates an efficient knowledge-based system and a component-based framework to design an intelligent and flexible home health care system. The proposed knowledge-based system integrates an efficient rule-based reasoning model and flexible knowledge rules for determining efficiently and rapidly the necessary physiological and medication treatment procedures based on software modules, video camera sensors, communication devices, and physiological sensor information. This knowledge-based system offers high flexibility for improving and extending the system further to meet the monitoring demands of new patient and caregiver health care by updating the knowledge rules in the inference mechanism. All of the proposed functional components in this study are reusable, configurable, and extensible for system developers. Based on the experimental results, the proposed intelligent homecare system demonstrates that it can accomplish the extensible, customizable, and configurable demands of the ubiquitous healthcare systems to meet the different demands of patients and caregivers under various rehabilitation and nursing conditions.

  16. An Intelligent Knowledge-Based and Customizable Home Care System Framework with Ubiquitous Patient Monitoring and Alerting Techniques

    Directory of Open Access Journals (Sweden)

    Yen-Lin Chen

    2012-08-01

    Full Text Available This study develops and integrates an efficient knowledge-based system and a component-based framework to design an intelligent and flexible home health care system. The proposed knowledge-based system integrates an efficient rule-based reasoning model and flexible knowledge rules for determining efficiently and rapidly the necessary physiological and medication treatment procedures based on software modules, video camera sensors, communication devices, and physiological sensor information. This knowledge-based system offers high flexibility for improving and extending the system further to meet the monitoring demands of new patient and caregiver health care by updating the knowledge rules in the inference mechanism. All of the proposed functional components in this study are reusable, configurable, and extensible for system developers. Based on the experimental results, the proposed intelligent homecare system demonstrates that it can accomplish the extensible, customizable, and configurable demands of the ubiquitous healthcare systems to meet the different demands of patients and caregivers under various rehabilitation and nursing conditions.

  17. Home video monitoring system for neurodegenerative diseases based on commercial HD cameras

    NARCIS (Netherlands)

    Abramiuc, B.; Zinger, S.; De With, P.H.N.; De Vries-Farrouh, N.; Van Gilst, M.M.; Bloem, B.; Overeem, S.

    2016-01-01

    Neurodegenerative disease (ND) is an umbrella term for chronic disorders that are characterized by severe joint cognitive-motor impairments, which are difficult to evaluate on a frequent basis. HD cameras in the home environment could extend and enhance the diagnosis process and could lead to better

  18. A new multidisciplinary home care telemedicine system to monitor stable chronic human immunodeficiency virus-infected patients: a randomized study.

    Science.gov (United States)

    León, Agathe; Cáceres, César; Fernández, Emma; Chausa, Paloma; Martin, Maite; Codina, Carles; Rousaud, Araceli; Blanch, Jordi; Mallolas, Josep; Martinez, Esteban; Blanco, Jose L; Laguno, Montserrat; Larrousse, Maria; Milinkovic, Ana; Zamora, Laura; Canal, Neus; Miró, Josep M; Gatell, Josep M; Gómez, Enrique J; García, Felipe

    2011-01-21

    Antiretroviral therapy has changed the natural history of human immunodeficiency virus (HIV) infection in developed countries, where it has become a chronic disease. This clinical scenario requires a new approach to simplify follow-up appointments and facilitate access to healthcare professionals. We developed a new internet-based home care model covering the entire management of chronic HIV-infected patients. This was called Virtual Hospital. We report the results of a prospective randomised study performed over two years, comparing standard care received by HIV-infected patients with Virtual Hospital care. HIV-infected patients with access to a computer and broadband were randomised to be monitored either through Virtual Hospital (Arm I) or through standard care at the day hospital (Arm II). After one year of follow up, patients switched their care to the other arm. Virtual Hospital offered four main services: Virtual Consultations, Telepharmacy, Virtual Library and Virtual Community. A technical and clinical evaluation of Virtual Hospital was carried out. Of the 83 randomised patients, 42 were monitored during the first year through Virtual Hospital (Arm I) and 41 through standard care (Arm II). Baseline characteristics of patients were similar in the two arms. The level of technical satisfaction with the virtual system was high: 85% of patients considered that Virtual Hospital improved their access to clinical data and they felt comfortable with the videoconference system. Neither clinical parameters [level of CD4+ T lymphocytes, proportion of patients with an undetectable level of viral load (p = 0.21) and compliance levels >90% (p = 0.58)] nor the evaluation of quality of life or psychological questionnaires changed significantly between the two types of care. Virtual Hospital is a feasible and safe tool for the multidisciplinary home care of chronic HIV patients. Telemedicine should be considered as an appropriate support service for the management of

  19. Design and development of an impedimetric-based system for the remote monitoring of home-based dialysis patients.

    Science.gov (United States)

    Montalibet, Amalric; Arkouche, Walid; Bogónez Franco, Paco; Bonnet, Stéphane; Clarion, Antoine; Delhomme, Georges; Géhin, Claudine; Gharbi, Sadok; Guillemaud, Régis; Jallon, Pierre; Massot, Bertrand; Pham, Pascale; Ribbe-Cornet, Eva; McAdams, Eric

    2016-01-01

    A key clinical challenge is to determine the desired 'dry weight' of a patient in order to terminate the dialysis procedure at the optimal moment and thus avoid the effects of over- and under-hydration. It has been found that the effects of haemodialysis on patients can be conveniently monitored using whole-body bioimpedance measurements. The identified need of assessing the hydrational status of patients undergoing haemodialysis at home gave rise to the present Dialydom (DIALYse à DOMicile) project. The aim of the project is to develop a convenient miniaturised impedance monitoring device for localised measurements (on the calf) in order to estimate an impedimetric hydrational index of the home-based patient, and to transmit this and other parameters to a remote clinical site. Many challenges must be overcome to develop a robust and valid home-based device. Some of these are presented in the paper.

  20. FY1995 report on the remote monitoring system for the aged at home; 1995 nendo zaitaku koreisha no kenko jotai enkaku kanshi system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The purpose of the project is to develop a prototype system which monitors the health conditions of the aged living alone by measuring his/her electronic cardiograms at sleep and the activity of movement at daytime which are gathered by telephone lines. The practicability of the system is also verified. After our newly developed health monitoring system was applied for one year in four people over age 80, this system is useful to monitor both ECG during night and the daily activity at home of the aged living alone for long term without being aware. In each subject, a unique pattern of ECG waveform and the daily activity at home was found. Since the individual activity was fairly stable throughout the year, we were able to point out the unusual days by comparing the daily activity pattern with the reference pattern and analysis the reason. As to the clinical problem, we called one subject to come to see a doctor after we found temporary ventricular arrhythmia in his record. On the occasion of unusual activity, we called the subject and/or his/her neighbors and found a health problem. Depending on the response to the call, the system administrator took an appropriate action like informing the relatives or making a visit. (NEDO)

  1. Remote Monitoring Systems for Chronic Patients on Home Hemodialysis: Field Test of a Copresence-Enhanced Design.

    Science.gov (United States)

    Liu, Na; Kim, Jinman; Jung, Younhyun; Arisy, Adani; Nicdao, Mary Ann; Mikaheal, Mary; Baldacchino, Tanya; Khadra, Mohamed; Sud, Kamal

    2017-08-29

    Patients undertaking long-term and chronic home hemodialysis (HHD) are subject to feelings of isolation and anxiety due to the absence of physical contact with their health care professionals and lack of feedback in regards to their dialysis treatments. Therefore, it is important for these patients to feel the "presence" of the health care professionals remotely while on hemodialysis at home for better compliance with the dialysis regime and to feel connected with health care professionals. This study presents an HHD system design for hemodialysis patients with features to enhance patient's perceived "copresence" with their health care professionals. Various mechanisms to enhance this perception were designed and implemented, including digital logbooks, emotion sharing, and feedback tools. The mechanism in our HHD system aims to address the limitations associated with existing self-monitoring tools for HHD patients. A field trial involving 3 nurses and 74 patients was conducted to test the pilot implementation of the copresence design in our HHD system. Mixed method research was conducted to evaluate the system, including surveys, interviews, and analysis of system data. Patients created 2757 entries of dialysis cases during the period of study. Altogether there were 492 entries submitted with "Very Happy" as the emotional status, 2167 entries with a "Happy" status, 56 entries with a "Neutral" status, 18 entries with an "Unhappy" status, and 24 entries with a "Very unhappy" status. Patients felt assured to share their emotions with health care professionals. Health care professionals were able to prioritize the review of the entries based on the emotional status and also felt assured to see patients' change in mood. There were 989 entries sent with short notes. Entries with negative emotions had a higher percentage of supplementary notes entered compared to the entries with positive and neutral emotions. The qualitative data further showed that the HHD system was

  2. Beyond Home Automation: Designing More Effective Smart Home Systems

    OpenAIRE

    Carner, Paolo

    2009-01-01

    This paper outlines a Smart Home Proof-of-Concept system that uses a Bayesian Network to predict the likelihood of a monitored event to occur. Firstly, this paper will provide an introduction to the concept of a smart home system; then it will outline how Artificial Intelligence concepts can be used to make such systems more effective. Finally, it will detail the implementation of a smart home system, which uses an inference engine to determine the likelihood of a fire. The system prototype h...

  3. Home energy monitors : Impact over the medium-term

    NARCIS (Netherlands)

    Van Dam, S.S.; Bakker, C.A.; Van Hal, J.D.M.

    2010-01-01

    Home Energy Management Systems (HEMS), e.g. energy monitors, are intermediary products that can visualize, manage, and/or monitor the energy use of other products or whole households. HEMS increasingly receive attention for their role in energy conservation in households. A literature review and a

  4. Monitoring results for the Factor 9 home

    International Nuclear Information System (INIS)

    Fugler, D.; Dumont, R.

    2009-01-01

    The Factor 9 home is a new demonstration project that consists of a single family residence located in Regina, Saskatchewan. The home features extremely high levels of energy and water use efficiency. The home was completed in April 2007. Energy and water savings targets were established for the Factor 9 home. In order to assess the extent to which the performance objectives were met, a project was undertaken to monitor energy and water use for a one-year period ending May 31, 2008. Several indoor air quality indicators were also measured. This paper discussed the findings of the project, with particular reference to energy conservation features; water conservation features; performance results; incremental cost of energy and water efficiency features; indoor air quality; and suggested improvements to the Factor 9 home. It was concluded that the demonstration project house showcased high levels of energy efficiency, renewable energy, and water efficiency with proven technologies. 3 refs., 4 figs.

  5. Characterization of a multi-user indoor positioning system based on low cost depth vision (Kinect) for monitoring human activity in a smart home.

    Science.gov (United States)

    Sevrin, Loïc; Noury, Norbert; Abouchi, Nacer; Jumel, Fabrice; Massot, Bertrand; Saraydaryan, Jacques

    2015-01-01

    An increasing number of systems use indoor positioning for many scenarios such as asset tracking, health care, games, manufacturing, logistics, shopping, and security. Many technologies are available and the use of depth cameras is becoming more and more attractive as this kind of device becomes affordable and easy to handle. This paper contributes to the effort of creating an indoor positioning system based on low cost depth cameras (Kinect). A method is proposed to optimize the calibration of the depth cameras, to describe the multi-camera data fusion and to specify a global positioning projection to maintain the compatibility with outdoor positioning systems. The monitoring of the people trajectories at home is intended for the early detection of a shift in daily activities which highlights disabilities and loss of autonomy. This system is meant to improve homecare health management at home for a better end of life at a sustainable cost for the community.

  6. Monitoring and evaluation of Solar Home Systems. Experiences with applications of solar PV for households in developing countries

    International Nuclear Information System (INIS)

    Nieuwenhout, F.D.J.; Van Dijk, A.; Van Dijk, V.A.P.; Hirsch, D.; Lasschuit, P.E.; Van Roekel, G.; Arriaza, H.; Hankins, M.; Sharma, B.D.; Wade, H.

    2000-09-01

    Solar energy is a promising solution to meet demand for electricity services of rural households in remote locations in developing countries. After some early successes, more and more doubts have arisen about the effectiveness and suitability of small PV systems for rural development. Many organisational, financial and technical problems appear difficult to tackle. A literature survey has been conducted to make an inventory of experiences with solar photovoltaic applications for households in developing countries. The major conclusion from the extensive literature research performed during this study is that there is not enough information available about the performance of solar home systems and projects. This slows down further development and successful dissemination. refs

  7. "SmartMonitor"--an intelligent security system for the protection of individuals and small properties with the possibility of home automation.

    Science.gov (United States)

    Frejlichowski, Dariusz; Gościewska, Katarzyna; Forczmański, Paweł; Hofman, Radosław

    2014-06-05

    "SmartMonitor" is an intelligent security system based on image analysis that combines the advantages of alarm, video surveillance and home automation systems. The system is a complete solution that automatically reacts to every learned situation in a pre-specified way and has various applications, e.g., home and surrounding protection against unauthorized intrusion, crime detection or supervision over ill persons. The software is based on well-known and proven methods and algorithms for visual content analysis (VCA) that were appropriately modified and adopted to fit specific needs and create a video processing model which consists of foreground region detection and localization, candidate object extraction, object classification and tracking. In this paper, the "SmartMonitor" system is presented along with its architecture, employed methods and algorithms, and object analysis approach. Some experimental results on system operation are also provided. In the paper, focus is put on one of the aforementioned functionalities of the system, namely supervision over ill persons.

  8. Get the Most Out of Home Blood Pressure Monitoring

    Science.gov (United States)

    Get the most out of home blood pressure monitoring Checking your blood pressure at home is an important part of managing ... monitors might not give you an accurate reading. Most pharmacies, medical supply stores and some websites sell ...

  9. Non-invasive, home-based electroencephalography hypoglycaemia warning system for personal monitoring using skin surface electrodes: a single-case feasibility study.

    Science.gov (United States)

    Clewett, Christopher J; Langley, Phillip; Bateson, Anthony D; Asghar, Aziz; Wilkinson, Antony J

    2016-03-01

    Hypoglycaemia unawareness is a common condition associated with increased risk of severe hypoglycaemia. The purpose of the authors' study was to develop a simple to use, home-based and non-invasive hypoglycaemia warning system based on electroencephalography (EEG), and to demonstrate its use in a single-case feasibility study. A participant with type 1 diabetes forms a single-person case study where blood sugar levels and EEG were recorded. EEG was recorded using skin surface electrodes placed behind the ear located within the T3 region by the participant in the home. EEG was analysed retrospectively to develop an algorithm which would trigger a warning if EEG changes associated with hypoglycaemia onset were detected. All hypoglycaemia events were detected by the EEG hypoglycaemia warning algorithm. Warnings were triggered with blood glucose concentration levels at or below 4.2 mmol/l in this participant and no warnings were issued when in euglycaemia. The feasibility of a non-invasive EEG-based hypoglycaemia warning system for personal monitoring in the home has been demonstrated in a single case study. The results suggest that further studies are warranted to evaluate the system prospectively in a larger group of participants.

  10. The Fresenius Medical Care home hemodialysis system.

    Science.gov (United States)

    Schlaeper, Christian; Diaz-Buxo, Jose A

    2004-01-01

    The Fresenius Medical Care home dialysis system consists of a newly designed machine, a central monitoring system, a state-of-the-art reverse osmosis module, ultrapure water, and all the services associated with a successful implementation. The 2008K@home hemodialysis machine has the flexibility to accommodate the changing needs of the home hemodialysis patient and is well suited to deliver short daily or prolonged nocturnal dialysis using a broad range of dialysate flows and concentrates. The intuitive design, large graphic illustrations, and step-by-step tutorial make this equipment very user friendly. Patient safety is assured by the use of hydraulic systems with a long history of reliability, smart alarm algorithms, and advanced electronic monitoring. To further patient comfort with their safety at home, the 2008K@home is enabled to communicate with the newly designed iCare remote monitoring system. The Aquaboss Smart reverse osmosis (RO) system is compact, quiet, highly efficient, and offers an improved hygienic design. The RO module reduces water consumption by monitoring the water flow of the dialysis system and adjusting water production accordingly. The Diasafe Plus filter provides ultrapure water, known for its long-term benefits. This comprehensive approach includes planning, installation, technical and clinical support, and customer service.

  11. Home Automation and Security System

    OpenAIRE

    Surinder Kaur,; Rashmi Singh; Neha Khairwal; Pratyk Jain

    2016-01-01

    Easy Home or Home automation plays a very important role in modern era because of its flexibility in using it at different places with high precision which will save money and time by decreasing human hard work. Prime focus of this technology is to control the household equipment’s like light, fan, door, AC etc. automatically. This research paper has detailed information on Home Automation and Security System using Arduino, GSM and how we can control home appliances using Android application....

  12. 基于BOA网络与GPRS的智能家居监控系统%Smart Home Monitoring System Based on BOA Network and GPRS

    Institute of Scientific and Technical Information of China (English)

    王聪; 王鹏

    2011-01-01

    In this paper, a method for smart home control GPRS module through BOA web server is proposed, then system based on ARM 9 core S3C2440 and SIM300 the design method of the system hardware platform and the system software based on CGI is also represented, this system has feature of having higher HTTP request processing speed, it can realize high-speed and high-efficient home monitoring, it is valuable to other system's development based on embedded system and network.%提出了一种基于ARM9核心的S3C2440 CPU、SIM300 GPRS无线传输模块及BOA网络服务器的智能家居监控系统设计方案,给出了系统硬件平台的设计方案,搭建了BOA网络服务器,并编制了基于CGI规范集的系统软件.此设计方案具有较高的HTTP请求处理速度,可以实现高速、高效的家居监控,同时在其它基于嵌入式及网络平台的相关设计中也具有一定的参考价值.

  13. Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System.

    Science.gov (United States)

    de Gennaro, Gianluigi; Dambruoso, Paolo Rosario; Di Gilio, Alessia; Di Palma, Valerio; Marzocca, Annalisa; Tutino, Maria

    2015-12-24

    Around 50% of the world's population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM) and polycyclic aromatic hydrocarbons (PAHs). The paper presents the results of Indoor Air Quality (IAQ) measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m³, 350.7 μg/m³ and 16.8 μg/m³ respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m³, while the maximum and the minimum values were 24.0 ng/m³ and 1.5 ng/m³, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP) and Total Volatile Organic Compounds (TVOC) was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants' concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system.

  14. Discontinuous and Continuous Indoor Air Quality Monitoring in Homes with Fireplaces or Wood Stoves as Heating System

    Directory of Open Access Journals (Sweden)

    Gianluigi de Gennaro

    2015-12-01

    Full Text Available Around 50% of the world’s population, particularly in developing countries, uses biomass as one of the most common fuels. Biomass combustion releases a considerable amount of various incomplete combustion products, including particulate matter (PM and polycyclic aromatic hydrocarbons (PAHs. The paper presents the results of Indoor Air Quality (IAQ measurements in six houses equipped with wood burning stoves or fireplaces as heating systems. The houses were monitored for 48-h periods in order to collect PM10 samples and measure PAH concentrations. The average, the maximum and the lowest values of the 12-h PM10 concentration were 68.6 μg/m3, 350.7 μg/m3 and 16.8 μg/m3 respectively. The average benzo[a]pyrene 12-h concentration was 9.4 ng/m3, while the maximum and the minimum values were 24.0 ng/m3 and 1.5 ng/m3, respectively. Continuous monitoring of PM10, PAHs, Ultra Fine Particle (UFP and Total Volatile Organic Compounds (TVOC was performed in order to study the progress of pollution phenomena due to biomass burning, their trends and contributions to IAQ. The results show a great heterogeneity of impacts on IAQ in terms of magnitude and behavior of the considered pollutants’ concentrations. This variability is determined by not only different combustion technologies or biomass quality, but overall by different ignition mode, feeding and flame management, which can also be different for the same house. Moreover, room dimensions and ventilation were significant factors for pollution dispersion. The increase of PM10, UFP and PAH concentrations, during lighting, was always detected and relevant. Continuous monitoring allowed singling out contributions of other domestic sources of considered pollutants such as cooking and cigarettes. Cooking contribution produced an impact on IAQ in same cases higher than that of the biomass heating system.

  15. The Development of Smart Home System for Controlling and Monitoring Energy Consumption using WebSocket Protocol

    Science.gov (United States)

    Witthayawiroj, Niti; Nilaphruek, Pongpon

    2017-03-01

    Energy consumption especially electricity is considered one of the most serious problems in households these days. It is because the amount of electricity consumed is more than the amount that people actually need. This means that there is an overusing which resulted from the inconvenience of moving to the switch to turn off the light or any appliances and it is often that closing the light is forgettable, for instance; in addition, there are no tools for monitoring how much energy that is consumed in residents. From this, it can be easily seen that people are having a problem in energy usage monitor and control. There are two main objectives of this study including 1) creating the communication framework among server, clients and devices, and 2) developing the prototype system that try to solve the mentioned problems which gives the user an opportunity to know the amount of electricity they have used in their houses and also the ability to turn appliances on and off through the Internet on smart devices such as smart phones and tablets that support Android platform or any web browser. Raspberry Pi is used as a microcontroller and the data is transferred to the smart device by WebSocket protocol which is strongly recommended for real-time communication. The example features on the device’s screen are user management, controlling and monitoring of appliances. The result expresses that the system is very effective and not difficult to use from users’ satisfaction. However, current sensors may be used for a more accurate electricity measurement and Wi-Fi module for more appliances to calculate its power in the future.

  16. Genetics Home Reference: systemic scleroderma

    Science.gov (United States)

    ... Facebook Twitter Home Health Conditions Systemic scleroderma Systemic scleroderma Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Systemic scleroderma is an autoimmune disorder that affects the skin ...

  17. Automated high-performance cIMT measurement techniques using patented AtheroEdge™: a screening and home monitoring system.

    Science.gov (United States)

    Molinari, Filippo; Meiburger, Kristen M; Suri, Jasjit

    2011-01-01

    The evaluation of the carotid artery wall is fundamental for the assessment of cardiovascular risk. This paper presents the general architecture of an automatic strategy, which segments the lumen-intima and media-adventitia borders, classified under a class of Patented AtheroEdge™ systems (Global Biomedical Technologies, Inc, CA, USA). Guidelines to produce accurate and repeatable measurements of the intima-media thickness are provided and the problem of the different distance metrics one can adopt is confronted. We compared the results of a completely automatic algorithm that we developed with those of a semi-automatic algorithm, and showed final segmentation results for both techniques. The overall rationale is to provide user-independent high-performance techniques suitable for screening and remote monitoring.

  18. Disease management: atrial fibrillation and home monitoring.

    Science.gov (United States)

    Ricci, Renato Pietro

    2013-06-01

    Device-detected atrial fibrillation (AF) episodes predict poor clinical outcome regardless of symptoms. Potential benefits of remote monitoring are early arrhythmia detection and patient continuous monitoring. Several studies of device remote monitoring consistently demonstrated that AF represents the most common clinical alert and that detailed information on arrhythmia onset, duration, and burden as well as on the ventricular rate may be early available for clinical evaluation. Reaction time to AF alerts was very short in all series involving either pacemakers or defibrillators and action ability of AF alerts was very high. In the Home Guide Registry, in which 1650 patients were enrolled, AF was detected in 16.3% of patients and represented 36% of all cardiovascular events during the follow-up. Timely anticoagulation introduction in asymptomatic patients may impact on the stroke rate. According to the results of repeated Monte Carlo simulations based on a real population of 166 patients, daily monitoring may reduce the 2-year stroke risk by 9-18% with an absolute reduction of 0.2-0.6%, compared with conventional inter-visit intervals of 6-12 months. In the COMPAS trial, the incidence of hospitalizations for atrial arrhythmias and related stroke was significantly higher in the control group than in the remote monitoring group. Major questions will be addressed by the ongoing IMPACT trial in which a remote monitoring guided anticoagulation strategy based on AF detection will be compared with a physician-directed standard strategy. In patients with heart failure, AF early detection combined with other indexes may help prevent hospitalizations.

  19. Smart and usable home energy management systems

    NARCIS (Netherlands)

    Van Dam, S.S.

    2009-01-01

    This paper reviews research into Home Energy Management Systems (HEMS). These are intermediary products that can visualize, manage, and/or monitor the energy use of other products or whole households. HEMS have lately received increasing attention for their possible role in conserving energy within

  20. Design of an IoT Enabled Local Network Based Home Monitoring System with a Priority Scheme

    Directory of Open Access Journals (Sweden)

    V. Tiwari

    2017-04-01

    Full Text Available Internet of things (IoT is a concept where all devices get connected to the internet to exchange information. IoT can be utilized in order to make a home environment interactive and smart. The required connectivity can be provided by either making all the devices Wi-Fi capable, which is costly, or by setting a local wireless sensor network (WSN which later connects to internet. In this work various devices and sensors are designed and connected in a wireless sensor network within a home environment which generates a sensor dependent data packet. These data packets are then sent to the cloud through a master node. The master sends the data using a proposed priority scheme so that the critical information can be sent early. Simulations were performed to show that under the proposed scheme the loss of critical sensors information is reduced by around 75%.

  1. Sms-Based Home Management System

    Directory of Open Access Journals (Sweden)

    Paing Soe Oo

    2015-08-01

    Full Text Available Mobile phones are widely used nowadays for different application such as wireless control and monitoring due to its availability and ease of use. The implemented system is based on global system mobile GSM network by using short message service SMS. The design mainly contains a GSM modem and Arduino Uno. In this work the system will be described how to manage and control home appliances using mobile phone people can use this system to do things in their home from a far place before they reach home. For instance user may controlmanage hisher home lighting door or water pump which needed in daily life in different area House Office or factory etc. when they are away from home. The user can check the condition in the home that light is on or off door is locked or unlocked water pump is on or off and so on. If the time taken for this appliances to perform a task is known that can also be set so that if the time elapsed the appliance will automatically switch off itself. The control is done by sending a specific SMS messages from smart phone to a SIM900 and Arduino Uno which is connected to the appliance once the message is received the SIM 900 will send the command to a microcontroller in Arduino for controlling the appliance appropriately. Also feedback status of three devices can be requested in designed system.

  2. Challenges in Control and Monitoring of Home-based Electronic Devices: A case for IoT-based Automation system

    OpenAIRE

    Kamulegeya Grace; Ssekanjako Kizito; Kalyesubula Noah; Kiryowa Francis; Mawanda Ian

    2018-01-01

    Internet of Things (IoT) is a concept that envisions all objects around us as part of internet. IoT coverage is very wide and includes variety of objects like smart phones, tablets, digital cameras and sensors. Home automation provides many kinds of services such as; reducing human labor, effort, time and errors due to human negligence. The increase in consumption of energy and population, has led to a grave need to conserve energy in every way possible. The inability to access and control th...

  3. Smart homes and home health monitoring technologies for older adults: A systematic review.

    Science.gov (United States)

    Liu, Lili; Stroulia, Eleni; Nikolaidis, Ioanis; Miguel-Cruz, Antonio; Rios Rincon, Adriana

    2016-07-01

    Around the world, populations are aging and there is a growing concern about ways that older adults can maintain their health and well-being while living in their homes. The aim of this paper was to conduct a systematic literature review to determine: (1) the levels of technology readiness among older adults and, (2) evidence for smart homes and home-based health-monitoring technologies that support aging in place for older adults who have complex needs. We identified and analyzed 48 of 1863 relevant papers. Our analyses found that: (1) technology-readiness level for smart homes and home health monitoring technologies is low; (2) the highest level of evidence is 1b (i.e., one randomized controlled trial with a PEDro score ≥6); smart homes and home health monitoring technologies are used to monitor activities of daily living, cognitive decline and mental health, and heart conditions in older adults with complex needs; (3) there is no evidence that smart homes and home health monitoring technologies help address disability prediction and health-related quality of life, or fall prevention; and (4) there is conflicting evidence that smart homes and home health monitoring technologies help address chronic obstructive pulmonary disease. The level of technology readiness for smart homes and home health monitoring technologies is still low. The highest level of evidence found was in a study that supported home health technologies for use in monitoring activities of daily living, cognitive decline, mental health, and heart conditions in older adults with complex needs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Usage monitoring of electrical devices in a smart home.

    Science.gov (United States)

    Rahimi, Saba; Chan, Adrian D C; Goubran, Rafik A

    2011-01-01

    Profiling the usage of electrical devices within a smart home can be used as a method for determining an occupant's activities of daily living. A nonintrusive load monitoring system monitors the electrical consumption at a single electrical source (e.g., main electric utility service entry) and the operating schedules of individual devices are determined by disaggregating the composite electrical consumption waveforms. An electrical device's load signature plays a key role in nonintrusive load monitoring systems. A load signature is the unique electrical behaviour of an individual device when it is in operation. This paper proposes a feature-based model, using the real power and reactive power as features for describing the load signatures of individual devices. Experimental results for single device recognition for 7 devices show that the proposed approach can achieve 100% classification accuracy with discriminant analysis using Mahalanobis distances.

  5. Solar home systems in Nepal

    Energy Technology Data Exchange (ETDEWEB)

    Henryson, Jessica; Haakansson, Teresa

    1999-04-01

    Photovoltaic (PV) technology is a clean and environmentally friendly technology that does not require any fuels. The high reliability of operation and little need for maintenance makes it ideally suited for rural areas. Today PV systems are used in Nepal to power telecommunications centres, navigational aids, in pumping systems for irrigation and drinking water, and for household electrification. A solar home system consists of a PV module, a battery, a charge controller and 3-4 fluorescent light bulbs with fixture. The system provides power for lighting and operation of household appliances for several hours. The success of donor supported programs have shown that solar home systems can be a practical solution for many rural households. In 1996 the Government of Nepal launched a subsidy program for solar home systems, which dramatically has increased the demand for solar home systems among rural customers. This report includes a survey of 52 households with solar home systems in two villages. The field-study shows that the villagers are very happy with their systems and the technical performance of the systems in both villages is satisfactory. The study also shows the positive impact electricity has on education, health, income generation and quality of life. The beneficiaries of introducing electricity in remote areas are the children and the women 39 refs, 18 tabs. Examination paper

  6. Robust ballistocardiogram acquisition for home monitoring

    International Nuclear Information System (INIS)

    Inan, O T; Etemadi, M; Giovangrandi, L; Kovacs, G T A; Wiard, R M

    2009-01-01

    The ballistocardiogram (BCG) measures the reaction of the body to cardiac ejection forces, and is an effective, non-invasive means of evaluating cardiovascular function. A simple, robust method is presented for acquiring high-quality, repeatable BCG signals from a modified, commercially available scale. The measured BCG waveforms for all subjects qualitatively matched values in the existing literature and physiologic expectations in terms of timing and IJ amplitude. Additionally, the BCG IJ amplitude was shown to be correlated with diastolic filling time for a subject with premature atrial contractions, demonstrating the sensitivity of the apparatus to beat-by-beat hemodynamic changes. The signal-to-noise ratio (SNR) of the BCG was estimated using two methods, and the average SNR over all subjects was greater than 12 for both estimates. The BCG measurement was shown to be repeatable over 50 recordings taken from the same subject over a three week period. This approach could allow patients at home to monitor trends in cardiovascular health

  7. Randomized trial of the ForeseeHome monitoring device for early detection of neovascular age-related macular degeneration. The HOme Monitoring of the Eye (HOME) study design - HOME Study report number 1.

    Science.gov (United States)

    Chew, Emily Y; Clemons, Traci E; Bressler, Susan B; Elman, Michael J; Danis, Ronald P; Domalpally, Amitha; Heier, Jeffrey S; Kim, Judy E; Garfinkel, Richard A

    2014-03-01

    To evaluate the effects of a home-monitoring device with tele-monitoring compared with standard care in detection of progression to choroidal neovascularization (CNV) associated with age-related macular degeneration (AMD), the leading cause of blindness in the US. Participants, aged 55 to 90 years, at high risk of developing CNV associated with AMD were recruited to the HOme Monitoring of Eye (HOME) Study, an unmasked, multi-center, randomized trial of the ForeseeHome (FH) device plus standard care vs. standard care alone. The FH device utilizes preferential hyperacuity perimetry and tele-monitoring to detect changes in vision function associated with development of CNV, potentially prior to symptom and visual acuity loss. After establishing baseline measurements, subsequent changes on follow-up are detected by the device, causing the monitoring center to alert the clinical center to recall participants for an exam. Standard care consists of instructions for self-monitoring visual changes with subsequent self-report to the clinical center. The primary objective of this study is to determine whether home monitoring plus standard care in comparison with standard care alone, results in earlier detection of incident CNV with better present visual acuity. The primary outcome is the decline in visual acuity at CNV diagnosis from baseline. Detection of CNV prior to substantial vision loss is critical as vision outcome following anti-angiogenic therapy is dependent on the visual acuity at initiation of treatment. HOME Study is the first large scale study to test the use of home tele-monitoring system in the management of AMD patients. Published by Elsevier Inc.

  8. SMS security system for smart home detectors

    OpenAIRE

    Cekova, Katerina; Gelev, Saso

    2016-01-01

    Security has always been an important problem everywhere. Home security has been a major issue where crime is increasing and everybody wants home security to protect the home. Safety from theft and flame are the most important requirements of a home security system for people. A remote home security system offers many benefits from keeping homeowners, and their property safe. This paper present controlling of the home security system remotely from Android Application. Owners can turn on or...

  9. Home security system using internet of things

    Science.gov (United States)

    Anitha, A.

    2017-11-01

    IoT refers to the infrastructure of connected physical devices which is growing at a rapid rate as huge number of devices and objects are getting associated to the Internet. Home security is a very useful application of IoT and we are using it to create an inexpensive security system for homes as well as industrial use. The system will inform the owner about any unauthorized entry or whenever the door is opened by sending a notification to the user. After the user gets the notification, he can take the necessary actions. The security system will use a microcontroller known as Arduino Uno to interface between the components, a magnetic Reed sensor to monitor the status, a buzzer for sounding the alarm, and a WiFi module, ESP8266 to connect and communicate using the Internet. The main advantages of such a system includes the ease of setting up, lower costs and low maintenance.

  10. Blood Pressure Home Monitoring in Hypertensive Patients Attending ...

    African Journals Online (AJOL)

    Blood Pressure Home Monitoring in Hypertensive Patients Attending a Tertiary ... Sixty percent of the patients were aged 50 - 69 years. ... Patients with high BP readings reported that they exercise more and reduced their daily salt intake.

  11. Inductive Monitoring System (IMS)

    Data.gov (United States)

    National Aeronautics and Space Administration — IMS: Inductive Monitoring System The Inductive Monitoring System (IMS) is a tool that uses a data mining technique called clustering to extract models of normal...

  12. A remote data access architecture for home-monitoring health-care applications.

    Science.gov (United States)

    Lin, Chao-Hung; Young, Shuenn-Tsong; Kuo, Te-Son

    2007-03-01

    With the aging of the population and the increasing patient preference for receiving care in their own homes, remote home care is one of the fastest growing areas of health care in Taiwan and many other countries. Many remote home-monitoring applications have been developed and implemented to enable both formal and informal caregivers to have remote access to patient data so that they can respond instantly to any abnormalities of in-home patients. The aim of this technology is to give both patients and relatives better control of the health care, reduce the burden on informal caregivers and reduce visits to hospitals and thus result in a better quality of life for both the patient and his/her family. To facilitate their widespread adoption, remote home-monitoring systems take advantage of the low-cost features and popularity of the Internet and PCs, but are inherently exposed to several security risks, such as virus and denial-of-service (DoS) attacks. These security threats exist as long as the in-home PC is directly accessible by remote-monitoring users over the Internet. The purpose of the study reported in this paper was to improve the security of such systems, with the proposed architecture aimed at increasing the system availability and confidentiality of patient information. A broker server is introduced between the remote-monitoring devices and the in-home PCs. This topology removes direct access to the in-home PC, and a firewall can be configured to deny all inbound connections while the remote home-monitoring application is operating. This architecture helps to transfer the security risks from the in-home PC to the managed broker server, on which more advanced security measures can be implemented. The pros and cons of this novel architecture design are also discussed and summarized.

  13. Smart GSM Based Home Automation System

    OpenAIRE

    Teymourzadeh, Rozita

    2013-01-01

    This research work investigates the potential of ‘Full Home Control’, which is the aim of the Home Automation Systems in near future. The analysis and implementation of the home automation technology using Global System for Mobile Communication (GSM) modem to control home appliances such as light, conditional system, and security system via Short Message Service (SMS) text messages is presented in this paper. The proposed research work is focused on the functionality of the GSM protocol, whic...

  14. Smart home design for electronic devices monitoring based wireless gateway network using cisco packet tracer

    Science.gov (United States)

    Sihombing, Oloan; Zendrato, Niskarto; Laia, Yonata; Nababan, Marlince; Sitanggang, Delima; Purba, Windania; Batubara, Diarmansyah; Aisyah, Siti; Indra, Evta; Siregar, Saut

    2018-04-01

    In the era of technological development today, the technology has become the need for the life of today's society. One is needed to create a smart home in turning on and off electronic devices via smartphone. So far in turning off and turning the home electronic device is done by pressing the switch or remote button, so in control of electronic device control less effective. The home smart design is done by simulation concept by testing system, network configuration, and wireless home gateway computer network equipment required by a smart home network on cisco packet tracer using Internet Thing (IoT) control. In testing the IoT home network wireless network gateway system, multiple electronic devices can be controlled and monitored via smartphone based on predefined configuration conditions. With the Smart Ho me can potentially increase energy efficiency, decrease energy usage costs, control electronics and change the role of residents.

  15. Designing Intuitive Web Solutions for Monitoring Patients’ Rehabilitation at Home

    Directory of Open Access Journals (Sweden)

    Raihana Ferdous

    2015-12-01

    Full Text Available This paper describes the design of web-based remote monitoring interfaces aimed at supporting therapists and caregivers in supervising motor-cognitive rehabilitation plans of care to be performed by patients at home. This work was part of a three years’ research project where game-based environments for upper body motor rehabilitation of post-stroke patients were developed in collaboration with two main rehabilitation centers in Italy and Austria, for a subsequent deployment at patients’ homes. The paper will specifically focus on describing the iterative design of the home rehabilitation features for clinicians over the first two years of the project to enable the delivery and monitoring of more personalized, engaging plans of care for home therapy by rehabilitation centers and services.

  16. [Possibilities and limitations of telemedical home monitoring in ophthalmology].

    Science.gov (United States)

    Jürgens, C; Grossjohann, R; Tost, F

    2009-09-01

    For medical professionals, home monitoring represents an innovative health service for remote patient care: The patient may remain in his or her domestic environment and continue normal activities. The physician can also, through technical and organizational integration, provide medical attendance from his or her usual working environment. All in all, in the near future home monitoring can help provide sufficient health services while also enabling medical resources to be used more effectively. The patient may benefit from individually optimized treatment and active integration into medical care. The better we manage the technical, organizational, medical, legal, and economic challenges of telemedicine, the better we can minimize the limitations of telemedical home monitoring. Other existing subjective concerns will be eliminated only if telemedical concepts are adapted to the specific needs of affected patients and physicians.

  17. Design of Smart Home Systems Prototype Using MyRIO

    Science.gov (United States)

    Ratna Wati, Dwi Ann; Abadianto, Dika

    2017-06-01

    This paper presents the design of smart home systems prototype. It applies. MyRIO 1900 embedded device as the main controller of the smart home systems. The systems include wireless monitoring systems and email based notifications as well as data logging. The prototype systems use simulated sensor such as temperature sensor, push button as proximity sensor, and keypad while its simulated actuators are buzzer as alarm system, LED as light and LCD. Based on the test and analysis, the smart home systems prototype as well as the wireless monitoring systems have real time responses when input signals are available. Tbe performance of MyRIO controller is excellent and it results in a stable system.

  18. Activity monitoring systems in health care

    NARCIS (Netherlands)

    Kröse, B.; van Oosterhout, T.; van Kasteren, T.; Salah, A.A.; Gevers, T.

    2011-01-01

    This chapter focuses on activity monitoring in a home setting for health care purposes. First the most current sensing systems are described, which consist of wearable and ambient sensors. Then several approaches for the monitoring of simple actions are discussed, like falls or therapies. After

  19. Wireless Android Based Home Automation System

    Directory of Open Access Journals (Sweden)

    Muhammad Tanveer Riaz

    2017-01-01

    Full Text Available This manuscript presents a prototype and design implementation of an advance home automation system that uses Wi-Fi technology as a network infrastructure connecting its parts. The proposed system consists of two main components; the first part is the server, which presents system core that manages and controls user’s home. Users and system administrator can locally (Local Area Network or remotely (internet manage and control the system. Second part is the hardware interface module, which provides appropriate interface to sensors and actuator of home automation system. Unlike most of the available home automation system in the market, the proposed system is scalable that one server can manage many hardware interface modules as long as it exists within network coverage. System supports a wide range of home automation devices like appliances, power management components, and security components. The proposed system is better in terms of the flexibility and scalability than the commercially available home automation systems

  20. Remote Maintenance Monitoring System -

    Data.gov (United States)

    Department of Transportation — The Remote Maintenance and Monitoring System (RMMS) is a collection of subsystems that includes telecommunication components, hardware, and software, which serve to...

  1. Development of eHOME, a Mobile Instrument for Reporting, Monitoring, and Consulting Drug-Related Problems in Home Care: Human-Centered Design Study.

    Science.gov (United States)

    Dijkstra, Nienke Elske; Sino, Carolina Geertruida Maria; Heerdink, Eibert Rob; Schuurmans, Marieke Joanna

    2018-03-07

    Home care patients often use many medications and are prone to drug-related problems (DRPs). For the management of problems related to drug use, home care could add to the multidisciplinary expertise of general practitioners (GPs) and pharmacists. The home care observation of medication-related problems by home care employees (HOME)-instrument is paper-based and assists home care workers in reporting potential DRPs. To facilitate the multiprofessional consultation, a digital report of DRPs from the HOME-instrument and digital monitoring and consulting of DRPs between home care and general practices and pharmacies is desired. The objective of this study was to develop an electronic HOME system (eHOME), a mobile version of the HOME-instrument that includes a monitoring and a consulting system for primary care. The development phase of the Medical Research Council (MRC) framework was followed in which an iterative human-centered design (HCD) approach was applied. The approach involved a Delphi round for the context of use and user requirements analysis of the digital HOME-instrument and the monitoring and consulting system followed by 2 series of pilots for testing the usability and redesign. By using an iterative design approach and by involving home care workers, GPs, and pharmacists throughout the process as informants, design partners, and testers, important aspects that were crucial for system realization and user acceptance were revealed. Through the report webpage interface, which includes the adjusted content of the HOME-instrument and added home care practice-based problems, home care workers can digitally report observed DRPs. Furthermore, it was found that the monitoring and consulting webpage interfaces enable digital consultation between home care and general practices and pharmacies. The webpages were considered convenient, clear, easy, and usable. By employing an HCD approach, the eHOME-instrument was found to be an easy-to-use system. The systematic

  2. Home monitoring of blood pressure: patients' perception and role of ...

    African Journals Online (AJOL)

    Purpose: To explore the use of the blood pressure monitors by hypertensive patients in Jordanian homes and investigate their effect on emotional status and disease management, and the role of the pharmacist in this regard. Methods: This cross-sectional study was conducted over two months in 2012, in Amman, Jordan.

  3. Monitoring Cray Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Don E [ORNL; Ezell, Matthew A [ORNL; Becklehimer, Jeff [Cray, Inc.; Donovan, Matthew J [ORNL; Layton, Christopher C [ORNL

    2014-01-01

    While sites generally have systems in place to monitor the health of Cray computers themselves, often the cooling systems are ignored until a computer failure requires investigation into the source of the failure. The Liebert XDP units used to cool the Cray XE/XK models as well as the Cray proprietary cooling system used for the Cray XC30 models provide data useful for health monitoring. Unfortunately, this valuable information is often available only to custom solutions not accessible by a center-wide monitoring system or is simply ignored entirely. In this paper, methods and tools used to harvest the monitoring data available are discussed, and the implementation needed to integrate the data into a center-wide monitoring system at the Oak Ridge National Laboratory is provided.

  4. Safety system status monitoring

    International Nuclear Information System (INIS)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide

  5. Safety system status monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  6. Environmental radiation monitoring system

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  7. A Review of Systems and Technologies for Smart Homes and Smart Grids

    OpenAIRE

    Lobaccaro, Gabriele; Carlucci, Salvatore; Löfström, Erica

    2016-01-01

    In the actual era of smart homes and smart grids, advanced technological systems that allow the automation of domestic tasks are developing rapidly. There are numerous technologies and applications that can be installed in smart homes today. They enable communication between home appliances and users, and enhance home appliances’ automation, monitoring and remote control capabilities. This review article, by introducing the concept of the smart home and the advent of the smart grid, investiga...

  8. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  9. Personal computer based home automation system

    OpenAIRE

    Hellmuth, George F.

    1993-01-01

    The systems engineering process is applied in the development of the preliminary design of a home automation communication protocol. The objective of the communication protocol is to provide a means for a personal computer to communicate with adapted appliances in the home. A needs analysis is used to ascertain that a need exist for a home automation system. Numerous design alternatives are suggested and evaluated to determine the best possible protocol design. Coaxial cable...

  10. Evaluation of patients with stroke monitored by home care programs

    Directory of Open Access Journals (Sweden)

    Ana Railka de Souza Oliveira

    2013-10-01

    Full Text Available The purpose of this study was to evaluate the patient with a stroke in home treatment, investigating physical capacity, mental status and anthropometric analysis. This was a cross-sectional study conducted in Fortaleza/CE, from January to April of 2010. Sixty-one individuals monitored by a home care program of three tertiary hospitals were investigated, through interviews and the application of scales. The majority of individuals encountered were female (59%, elderly, bedridden, with a low educational level, a history of other stroke, a high degree of dependence for basic (73.8% and instrumental (80.3 % activities of daily living, and a low cognitive level (95.1%. Individuals also presented with tracheostomy, gastric feeding and urinary catheter, difficulty hearing, speaking, chewing, swallowing, and those making daily use of various medications. It was concluded that home care by nurses is an alternative for care of those individuals with a stroke.

  11. Evaluation of patients with stroke monitored by home care programs

    Directory of Open Access Journals (Sweden)

    Ana Railka de Souza Oliveira

    Full Text Available The purpose of this study was to evaluate the patient with a stroke in home treatment, investigating physical capacity, mental status and anthropometric analysis. This was a cross-sectional study conducted in Fortaleza/CE, from January to April of 2010. Sixty-one individuals monitored by a home care program of three tertiary hospitals were investigated, through interviews and the application of scales. The majority of individuals encountered were female (59%, elderly, bedridden, with a low educational level, a history of other stroke, a high degree of dependence for basic (73.8% and instrumental (80.3 % activities of daily living, and a low cognitive level (95.1%. Individuals also presented with tracheostomy, gastric feeding and urinary catheter, difficulty hearing, speaking, chewing, swallowing, and those making daily use of various medications. It was concluded that home care by nurses is an alternative for care of those individuals with a stroke.

  12. Genetics Home Reference: systemic lupus erythematosus

    Science.gov (United States)

    ... Twitter Home Health Conditions Systemic lupus erythematosus Systemic lupus erythematosus Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Systemic lupus erythematosus (SLE) is a chronic disease that causes inflammation ...

  13. The HomePort System

    DEFF Research Database (Denmark)

    Brønsted, Jeppe Rørbæk; Skou, Arne Joachim; Madsen, Per Printz

    2010-01-01

    Residential gateways for home automation are prerequisites to obtain optimal exploitation of energy resources, and they also have the potential to provide a unified operation of various home devices and appliances. Although a number of protocol standards have been proposed, the number...

  14. Reconfigurable Sensor Monitoring System

    Science.gov (United States)

    Alhorn, Dean C. (Inventor); Dutton, Kenneth R. (Inventor); Howard, David E. (Inventor); Smith, Dennis A. (Inventor)

    2017-01-01

    A reconfigurable sensor monitoring system includes software tunable filters, each of which is programmable to condition one type of analog signal. A processor coupled to the software tunable filters receives each type of analog signal so-conditioned.

  15. Design and Implementation of GSM Based Automated Home Security System

    Directory of Open Access Journals (Sweden)

    Love Aggarwal

    2014-05-01

    Full Text Available The Automated Home Security System aims at building a security system for common households using GSM modem, sensors and microcontroller. Since many years, impeccable security system has been the prime need of every man who owns a house. The increasing crime rate has further pressed the need for it. Our system is an initiative in this direction. The system provides security function by monitoring the surroundings at home for intruders, fire, gas leakages etc. using sensors and issue alerts to the owners and local authorities by using GSM via SMS. It provides the automation function as it can control (On/Off the various home appliances while the owners are away via SMS. Thus the Automated Home Security System is self-sufficient and can be relied upon undoubtedly. Also, it is capable of establishing two way communication with its owner so that he/she can keep a watch on his/her home via sensor information or live video streaming. A camera can be installed for continuous monitoring of the system and its surroundings. The system consists of two main parts: hardware and software. Hardware consists of Microcontroller, Sensors, Buzzer and GSM modem while software is implemented by tools using Embedded ‘C’.

  16. Automated Vehicle Monitoring System

    OpenAIRE

    Wibowo, Agustinus Deddy Arief; Heriansyah, Rudi

    2014-01-01

    An automated vehicle monitoring system is proposed in this paper. The surveillance system is based on image processing techniques such as background subtraction, colour balancing, chain code based shape detection, and blob. The proposed system will detect any human's head as appeared at the side mirrors. The detected head will be tracked and recorded for further action.

  17. Wireless Android Based Home Automation System

    OpenAIRE

    Muhammad Tanveer Riaz; Eman Manzoor Ahmed; Fariha Durrani; Muhammad Asim Mond

    2017-01-01

    This manuscript presents a prototype and design implementation of an advance home automation system that uses Wi-Fi technology as a network infrastructure connecting its parts. The proposed system consists of two main components; the first part is the server, which presents system core that manages and controls user’s home. Users and system administrator can locally (Local Area Network) or remotely (internet) manage and control the system. Second part is the hardware interface module, which p...

  18. Use of home blood-pressure monitoring in the detection, treatment and surveillance of hypertension.

    Science.gov (United States)

    Manning, Gillian; Donnelly, Richard

    2005-11-01

    Use of home blood-pressure monitoring is increasing but the technique and the equipment have limitations. We provide an overview of recent evidence in this rapidly evolving field. Home blood-pressure monitoring is an acceptable method for screening patients for hypertension. There is increasing evidence supporting the predictive power of home blood pressure for stroke risk even in the general population. The identification of white-coat and masked hypertension remains an important role for home blood-pressure monitoring. Unvalidated equipment and poor patient technique are major concerns. The purchase of devices needs to be linked to a simple patient-education programme, which is perhaps an opportunity for collaboration between healthcare providers and commercial companies. Devices that store the blood-pressure measurements in the memory are preferred to ensure accuracy of reporting. Data-transmission systems providing automatic storage, transmission and reporting of blood pressure, direct involvement of the patient and potentially a reduced number of hospital/general practitioner visits, offer significant advantages. To reduce patient anxiety, overuse of home blood-pressure monitoring should be avoided but there is the potential for self-modification of treatment, subject to certain safeguards. Self-monitoring of blood pressure is developing rapidly, linked to increasing awareness of the impact of reducing high blood pressure on public health and the marketing/advertising strategies used to sell automatic devices. Home blood-pressure monitoring has a role in the detection and management of blood pressure, but not at the expense of careful blood-pressure measurement in the office and adherence to national guidelines.

  19. Copilot: Monitoring Embedded Systems

    Science.gov (United States)

    Pike, Lee; Wegmann, Nis; Niller, Sebastian; Goodloe, Alwyn

    2012-01-01

    Runtime verification (RV) is a natural fit for ultra-critical systems, where correctness is imperative. In ultra-critical systems, even if the software is fault-free, because of the inherent unreliability of commodity hardware and the adversity of operational environments, processing units (and their hosted software) are replicated, and fault-tolerant algorithms are used to compare the outputs. We investigate both software monitoring in distributed fault-tolerant systems, as well as implementing fault-tolerance mechanisms using RV techniques. We describe the Copilot language and compiler, specifically designed for generating monitors for distributed, hard real-time systems. We also describe two case-studies in which we generated Copilot monitors in avionics systems.

  20. Enabling affordable and efficiently deployed location based smart home systems.

    Science.gov (United States)

    Kelly, Damian; McLoone, Sean; Dishongh, Terry

    2009-01-01

    With the obvious eldercare capabilities of smart environments it is a question of "when", rather than "if", these technologies will be routinely integrated into the design of future houses. In the meantime, health monitoring applications must be integrated into already complete home environments. However, there is significant effort involved in installing the hardware necessary to monitor the movements of an elder throughout an environment. Our work seeks to address the high infrastructure requirements of traditional location-based smart home systems by developing an extremely low infrastructure localisation technique. A study of the most efficient method of obtaining calibration data for an environment is conducted and different mobile devices are compared for localisation accuracy and cost trade-off. It is believed that these developments will contribute towards more efficiently deployed location-based smart home systems.

  1. System health monitoring

    International Nuclear Information System (INIS)

    Reneke, J.A.; Fryer, M.O.

    1995-01-01

    Well designed large systems include many instrument taking data. These data are used in a variety of ways. They are used to control the system and its components, to monitor system and component health, and often for historical or financial purposes. This paper discusses a new method of using data from low level instrumentation to monitor system and component health. The method uses the covariance of instrument outputs to calculate a measure of system change. The method involves no complicated modeling since it is not a parameter estimation algorithm. The method is iterative and can be implemented on a computer in real time. Examples are presented for a metal lathe and a high efficiency particulate air (HEPA) filter. It is shown that the proposed method is quite sensitive to system changes such as wear out and failure. The method is useful for low level system diagnostics and fault detection

  2. VME system monitor board

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Much of the machinery throughout the APS will be controlled by VME based computers. In order to increase the reliability of the system, it is necessary to be able to monitor the status of each VME crate. In order to do this, a VME System Monitor was created. In addition to being able to monitor and report the status (watchdog timer, temperature, CPU (Motorola MVME 167) state (status, run, fail), and the power supply), it includes provisions to remotely reset the CPU and VME crate, digital I/O, and parts of the transition module (serial port and ethernet connector) so that the Motorla MVME 712 is not needed. The standard VME interface was modified on the System Monitor so that in conjunction with the Motorola MVME 167 a message based VXI interrupt handler could is implemented. The System Monitor is a single VME card (6U). It utilizes both the front panel and the P2 connector for I/O. The front panel contains a temperature monitor, watchdog status LED, 4 general status LEDs, input for a TTL interrupt, 8 binary inputs (24 volt, 5 volt, and dry contact sense), 4 binary outputs (dry contact, TTL, and 100 mA), serial port (electrical RS-232 or fiber optic), ethernet transceiver (10 BASE-FO or AUI), and a status link to neighbor crates. The P2 connector is used to provide the serial port and ethernet to the processor. In order to abort and read the status of the CPU, a jumper cable must be connected between the CPU and the System Monitor.

  3. Home garden system dynamics in Southern Ethiopia

    NARCIS (Netherlands)

    Mellisse, Beyene Teklu; Ven, van de Gerrie W.J.; Giller, Ken E.; Descheemaeker, Katrien

    2017-01-01

    Home gardens in southern Ethiopia are regarded as efficient farming systems, allowing interactions and synergies between crop, tree and livestock components. However, these age-old traditional home gardens are evolving rapidly in response to changes in both the socio-economic and biophysical

  4. Quality and Safety of Home ICP Monitoring Compared with In-Hospital Monitoring

    DEFF Research Database (Denmark)

    Andresen, Morten; Juhler, Marianne; Munch, Tina Nørgaard

    2012-01-01

    Introduction: Intracranial pressure (ICP) monitoring is usually conducted in-hospital using stationary devices. Modern mobile ICP monitoring systems present new monitoring possibilities more closely following the patients' daily life. We reviewed patient safety, quality of technical data...

  5. On preventive blood pressure self-monitoring at home

    DEFF Research Database (Denmark)

    Verdezoto, Nervo; Grönvall, Erik

    2015-01-01

    for self-measuring, the importance of interpretation, understanding and health awareness, sharing self-monitoring information for prevention, various motivational factors, the role of the doctor in prevention, and the home as a distributed information space. An awareness of these aspects can help designers......, to understand existing challenges, and uncover opportunities for self-monitoring technologies to support preventive healthcare activities among older adults. From our study, several important aspects emerged to consider when designing preventive self-monitoring technology, such as the complexity of guidelines...... how these aspects can both inform people engaged in Quantified Self activities and designers alike, and the tools and approaches that have sprung from the so-called Quantified Self movement...

  6. Biowaste home composting: experimental process monitoring and quality control.

    Science.gov (United States)

    Tatàno, Fabio; Pagliaro, Giacomo; Di Giovanni, Paolo; Floriani, Enrico; Mangani, Filippo

    2015-04-01

    Because home composting is a prevention option in managing biowaste at local levels, the objective of the present study was to contribute to the knowledge of the process evolution and compost quality that can be expected and obtained, respectively, in this decentralized option. In this study, organized as the research portion of a provincial project on home composting in the territory of Pesaro-Urbino (Central Italy), four experimental composters were first initiated and temporally monitored. Second, two small sub-sets of selected provincial composters (directly operated by households involved in the project) underwent quality control on their compost products at two different temporal steps. The monitored experimental composters showed overall decreasing profiles versus composting time for moisture, organic carbon, and C/N, as well as overall increasing profiles for electrical conductivity and total nitrogen, which represented qualitative indications of progress in the process. Comparative evaluations of the monitored experimental composters also suggested some interactions in home composting, i.e., high C/N ratios limiting organic matter decomposition rates and final humification levels; high moisture contents restricting the internal temperature regime; nearly horizontal phosphorus and potassium evolutions contributing to limit the rates of increase in electrical conductivity; and prolonged biowaste additions contributing to limit the rate of decrease in moisture. The measures of parametric data variability in the two sub-sets of controlled provincial composters showed decreased variability in moisture, organic carbon, and C/N from the seventh to fifteenth month of home composting, as well as increased variability in electrical conductivity, total nitrogen, and humification rate, which could be considered compatible with the respective nature of decreasing and increasing parameters during composting. The modeled parametric kinetics in the monitored experimental

  7. Monitoring and Detection Platform to Prevent Anomalous Situations in Home Care

    Directory of Open Access Journals (Sweden)

    Gabriel Villarrubia

    2014-06-01

    Full Text Available Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost.

  8. Car monitoring information systems

    Directory of Open Access Journals (Sweden)

    Alica KALAŠOVÁ

    2008-01-01

    Full Text Available The objective of this contribution is to characterize alternatives of information systems used for managing, processing and evaluation of information related to company vehicles. Especially we focus on logging, transferring and processing of on-road vehicle movement information in inland and international transportation. This segment of company information system has to monitor the car movement – actively or passively – according to demand of the company and after the processing it has to evaluate and give the complex monitoring of a situation of all the company vehicles to the controller.

  9. Android based security and home automation system

    OpenAIRE

    Khan, Sadeque Reza; Dristy, Farzana Sultana

    2015-01-01

    The smart mobile terminal operator platform Android is getting popular all over the world with its wide variety of applications and enormous use in numerous spheres of our daily life. Considering the fact of increasing demand of home security and automation, an Android based control system is presented in this paper where the proposed system can maintain the security of home main entrance and also the car door lock. Another important feature of the designed system is that it can control the o...

  10. Home Photovoltaic System Design in Pangkalpinang City

    Science.gov (United States)

    Sunanda, Wahri

    2018-02-01

    This research aims to obtain the design of home photovoltaic systems in Pangkalpinang and the opportunity of economic savings. The system consists of photovoltaic with batteries. Based on electricity consumption of several houses with installed power of 1300 VA and 2200 VA in Pangkalpinang for one year, the daily load of photovoltaic system is varied to 40%, 30% and 20% of the average value of the daily home electricity consumption. The investment costs, the cost of replacement parts and the cost of electricity consumption accrued to PLN during lifetime of systems (25 years) are also calculated. The result provided that there are no economic saving opportunities for photovoltaic systems with batteries at home with installed power of 1300 VA and 2200 VA in Pangkalpinang. The most economical is the photovoltaic system with the daily load of 20% of the average value of the daily home electricity consumption. The configuration of photovoltaic system for 1300 VA home consists of 10 modules of 200 wattpeak and 4 batteries 150 AH, 12 Volt while photovoltaic system for 2200 VA home consists of 15 modules of 200 wattpeak and 6 batteries 150 AH,12Volt.

  11. Accuracy of home blood pressure readings: monitors and operators.

    Science.gov (United States)

    Stryker, Trina; Wilson, Merne; Wilson, Thomas W

    2004-06-01

    To evaluate the accuracy of automated digital blood pressure monitoring devices and operators in the community. Also, we tested the effects of a simple education program, and looked for arm-arm differences. Subjects who had bought their own automated digital blood pressure monitor were recruited via an advertisement in the local newspaper. On arrival, they were asked to record their blood pressure exactly as they would at home. The investigator noted any technique deficiencies then corrected them. Blood pressures were then recorded by the investigator and the subject, on opposite arms, simultaneously, and repeated with the arms switched. Finally, subjects recorded their blood pressure again. The subjects' readings were compared to the average of monitor and mercury readings using Bland-Altman methods. A total of 80 subjects were tested. Before educating, subjects' systolic blood pressure (SBP) readings were +5.8+/-6.4 (standard deviation) mmHg greater than the mean of all readings, and diastolic blood pressure (DBP) were +1.3+/-4.0 mmHg; after educating they were +1.3+/-4.0 and -1.3+/-2.7 respectively. The monitors, as a group, were accurate, and met British Hypertension Society and AAMI highest standards. We found no differences among monitors that had been validated (n=26) and those that had not. There were differences between the arms: 5.3+/-5.2 mmHg for SBP and 3.4+/-3.3 mmHg for DBP. Most patients had never been informed by anyone of proper blood pressure measuring techniques. We conclude that home blood pressure measurement, as practiced in our community, is prone to error, mostly due to mistakes by the operator. These can easily be corrected, so that readings become more accurate. Attention should be paid to arm-arm differences.

  12. Icinga Monitoring System Interface

    CERN Document Server

    Neculae, Alina Georgiana

    2014-01-01

    The aim of this project is to develop a web interface that would be used by the Icinga monitoring system to manage the CMS online cluster, in the experimental site. The interface would allow users to visualize the information in a compressed and intuitive way, as well as modify the information of each individual object and edit the relationships between classes.

  13. Beyond Patient Monitoring: Conversational Agents Role in Telemedicine & Healthcare Support For Home-Living Elderly Individuals

    OpenAIRE

    Fadhil, Ahmed

    2018-01-01

    There is a need for systems to dynamically interact with ageing populations to gather information, monitor health condition and provide support, especially after hospital discharge or at-home settings. Several smart devices have been delivered by digital health, bundled with telemedicine systems, smartphone and other digital services. While such solutions offer personalised data and suggestions, the real disruptive step comes from the interaction of new digital ecosystem, represented by chatb...

  14. New concepts and technologies in home care and ambulatory monitoring.

    Science.gov (United States)

    Dittmar, A; Axisa, F; Delhomme, G; Gehin, C

    2004-01-01

    The world is becoming more and more health conscious. Society, health policy and patients' needs are all changing dramatically. The challenges society is currently facing are related to the increase in the aging population, changes in lifestyle, the need for healthcare cost containment and the need for improvement and monitoring of healthcare quality. The emphasis is put on prevention rather than on treatment. In addition, patients and health consumers are waiting for non-invasive or minimally-invasive diagnosis and treatment methods, for home care, short stays in hospital, enhancement of rehabilitation, information and involvement in their own treatment. Progress in science and technology offers, today, miniaturization, speed, intelligence, sophistication and new materials at lower cost. In this new landscape, microtechnologies, information technologies and telecommunications are key factors. Telemedicine has also evolved. Used initially to exchange patients' files, radiographic data and other information between health providers, today telemedicine contributes to new trends in "hospital extension" through all-day monitoring of vital signs, professional activities, entertainment and home-based activities. The new possibilities for home care and ambulatory monitoring are provided at 4 levels: a) Microsensors. Microtechnologies offer the possibility of small size, but also of intelligent, active devices, working with low energy, wireless and non-invasive or minimally-invasive; b) Wrist devices are particularly user friendly and combine sensors, circuits, supply, display and wireless transmission in a single box, very convenient for common physical activities; c) Health smart clothes make contact with 90 % of the skin and offer many possibilities for the location of sensors. These sensors have to be thin, flexible and compatible with textiles, or made using textile technologies, such as new fibers with specific (mechanical, electrical and optical) properties; d

  15. Home electrical system safety in Italy

    Energy Technology Data Exchange (ETDEWEB)

    Auditor,

    1990-06-01

    Italy, amongst the industrialized countries, has the highest mortality rate due to accidents associated with the improper use or maintenance of home electrical systems. The increasing use of domestic electrical appliances has raised the risk of accidents, especially in homes equipped with out-dated, low-capacity electrical plants and worn wiring. Within this context, this paper reports on the results of survey to establish the worthiness and type of electrical systems in use in a sample of 1,000 residential buildings. The paper then assesses the efficacy of recent normatives designed to increase the safety and efficiency of home electrical installations.

  16. Home and Building Energy Management Systems | Grid Modernization | NREL

    Science.gov (United States)

    Home and Building Energy Management Systems Home and Building Energy Management Systems NREL researchers are developing tools to understand the impact of changes in home and building energy use and how researchers who received a record of invention for a home energy management system in a smart home laboratory

  17. Benzene Monitor System report

    International Nuclear Information System (INIS)

    Livingston, R.R.

    1992-01-01

    Two systems for monitoring benzene in aqueous streams have been designed and assembled by the Savannah River Technology Center, Analytical Development Section (ADS). These systems were used at TNX to support sampling studies of the full-scale open-quotes SRAT/SME/PRclose quotes and to provide real-time measurements of benzene in Precipitate Hydrolysis Aqueous (PHA) simulant. This report describes the two ADS Benzene Monitor System (BMS) configurations, provides data on system operation, and reviews the results of scoping tests conducted at TNX. These scoping tests will allow comparison with other benzene measurement options being considered for use in the Defense Waste Processing Facility (DWPF) laboratory. A report detailing the preferred BMS configuration statistical performance during recent tests has been issued under separate title: Statistical Analyses of the At-line Benzene Monitor Study, SCS-ASG-92-066. The current BMS design, called the At-line Benzene Monitor (ALBM), allows remote measurement of benzene in PHA solutions. The authors have demonstrated the ability to calibrate and operate this system using peanut vials from a standard Hydragard trademark sampler. The equipment and materials used to construct the ALBM are similar to those already used in other applications by the DWPF lab. The precision of this system (±0.5% Relative Standard Deviation (RSD) at 1 sigma) is better than the purge ampersand trap-gas chromatograpy reference method currently in use. Both BMSs provide a direct measurement of the benzene that can be purged from a solution with no sample pretreatment. Each analysis requires about five minutes per sample, and the system operation requires no special skills or training. The analyzer's computer software can be tailored to provide desired outputs. Use of this system produces no waste stream other than the samples themselves (i.e. no organic extractants)

  18. Home Automation System Using Capacitive Touchscreen

    OpenAIRE

    Yash Inaniya; Naresh Kumari

    2014-01-01

    Technology has been constantly evolving and with the advent of touchscreen in human life , devices are much easier and simple to operate. This work is mainly focused on building home automation system which is more user friendly and thus can be operated by anyone. Earlier home automation systems were completely mechanically operated and thus required a lot of maintenance and were costly also. Now that human and computer interaction has been developed into a more wide and sophi...

  19. Self-monitoring has potential for home exercise programmes in patients with haemophilia.

    Science.gov (United States)

    Goto, M; Takedani, H; Haga, N; Kubota, M; Ishiyama, M; Ito, S; Nitta, O

    2014-03-01

    Haemophiliacs who have had to keep a physically inactive lifestyle due to bleeding during childhood are likely to have little motivation for exercise. The purpose of this study is to clarify the effectiveness of the self-monitoring of home exercise for haemophiliacs. A randomized controlled trial was conducted with intervention over 8 weeks at four hospitals in Japan. Subjects included 32 male outpatients aged 26-64 years without an inhibitor who were randomly allocated to a self-monitoring group and a control group. Individual exercise guidance with physical activity for improvement of their knee functions was given to both groups. The self-monitoring materials included an activity monitor and a feedback system so that the self-monitoring group could send feedback via the Internet and cellular phone. The self-monitoring was performed by checking exercise adherence and physical activity levels, bleeding history and injection of a coagulation factor. Both groups showed significant improvements in exercise adherence (P self-efficacy (P self-monitoring group compared with those in the control group. No increase in bleeding frequency and pain scale was noted. The self-monitoring of home exercise for haemophilic patients is useful for the improvement of exercise adherence, self-efficacy and knee extension strength. © 2014 John Wiley & Sons Ltd.

  20. Optimisation and validation of a remote monitoring system (Onco-TreC) for home-based management of oral anticancer therapies: an Italian multicentre feasibility study.

    Science.gov (United States)

    Passardi, Alessandro; Rizzo, Mimma; Maines, Francesca; Tondini, Carlo; Zambelli, Alberto; Vespignani, Roberto; Andreis, Daniele; Massa, Ilaria; Dianti, Marco; Forti, Stefano; Piras, Enrico Maria; Eccher, Claudio

    2017-05-29

    Despite the growing number of oral agents available for cancer treatment, their efficacy may be reduced due to the lack of adherence, inappropriate adverse event self-management and arbitrary dose adjustment. The management of anticancer therapies could exponentially benefit from the introduction of mobile health technologies in a highly integrated electronic oncology system. We plan to customise and fine-tune an existing monitoring TreC platform used in different chronic diseases in the oncology setting. This project follows a multistep approach with two major purposes: 1. participatory design techniques driven by Health Literacy and Patient Reported Outcomes principles in order to adapt the system to the oncology setting involving patients and healthcare providers; 2. a prospective training-validation, interventional, non-pharmacological, multicentre study on a series of consecutive patients with cancer (20 and 60 patients in the training and validation steps, respectively) in order to assess system capability, usability and acceptability. The novel Onco-TreC 2.0 is expected to contribute to improving the adherence and safety of cancer care, promoting patient empowerment and patient-doctor communication. Ethical approval was obtained from the Independent Ethics Committees of the participating institutions (CEIIAV protocol Number 2549/2015; reference Number 1315-PU). Informed consent will be obtained from all study participants. Findings will be disseminated through peer-reviewed journals, conferences and event presentations. ClinicalTrials.gov (NCT02921724); (Pre-results). Other study ID Number: IRST100.18. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Corrosion Monitoring System

    Energy Technology Data Exchange (ETDEWEB)

    Dr. Russ Braunling

    2004-10-31

    The Corrosion Monitoring System (CMS) program developed and demonstrated a continuously on-line system that provides real-time corrosion information. The program focused on detecting pitting corrosion in its early stages. A new invention called the Intelligent Ultrasonic Probe (IUP) was patented on the program. The IUP uses ultrasonic guided waves to detect small defects and a Synthetic Aperture Focusing Technique (SAFT) algorithm to provide an image of the pits. Testing of the CMS demonstrated the capability to detect pits with dimensionality in the sub-millimeter range. The CMS was tested in both the laboratory and in a pulp and paper industrial plant. The system is capable of monitoring the plant from a remote location using the internet.

  2. Loose parts monitoring system

    International Nuclear Information System (INIS)

    Wakasa, Kohji; Nishida, Eiichi; Ishii, Kazuo; Yamanaka, Hiroto.

    1987-01-01

    In the loose parts monitoring system (LPMS), installed for integrity monitoring of the nuclear power plants; when there occur foreign metallic objects in the reactor primary system, including a steam generator and the piping, the sounds caused by them moving with the cooling water and thereby getting in contact with various structures are detected. Its purpose is, therefore, to detect any abnormality in the reactor plant system through such abnormal sounds due to loose or fallen supports etc., and so provide this information to the reactor operators. In principle, accelerometers are distributed in such as reactor vessel, steam generator, coolant pumps, etc., so that various sounds are collected and converted into electrical signals, followed by analysis of the data. Described are the LPMS configuration/functions, the course taken in LPMS development, future problems, etc. (Mori, K.)

  3. Whole-Home Dehumidifiers: Field-Monitoring Study

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Tom; Willem, Henry; Ni, Chun Chun; Stratton, Hannah; Whitehead, Camilla Dunham; Johnson, Russell

    2014-09-23

    Lawrence Berkeley National Laboratory (LBNL) initiated a WHD field-metering study to expand current knowledge of and obtain data on WHD operation and energy consumption in real-world applications. The field study collected real-time data on WHD energy consumption, along with information regarding housing characteristics, consumer behavior, and various outdoor conditions expected to affect WHD performance and efficiency. Although the metering study collected similar data regarding air conditioner operation, this report discusses only WHDs. The primary objectives of the LBNL field-metering study are to (1) expand knowledge of the configurations, energy consumption profiles, consumer patterns of use (e.g., relative humidity [RH] settings), and environmental parameters of whole-home dehumidification systems; and (2) develop distributions of hours of dehumidifier operation in four operating modes: off, standby, fan-only, and compressor (also called dehumidification mode). Profiling energy consumption entails documenting the power consumption, duration of power consumption in different modes, condensate generation, and properties of output air of an installed system under field conditions of varying inlet air temperature and RH, as well as system configuration. This profiling provides a more detailed and deeper understanding of WHD operation and its complexities. This report describes LBNL’s whole-home dehumidification field-metering study conducted at four homes in Wisconsin and Florida. The initial phase of the WHD field-metering study was conducted on one home in Madison, Wisconsin, from June to December of 2013. During a second phase, three Florida homes were metered from June to October of 2014. This report presents and examines data from the Wisconsin site and from the three Florida sites.

  4. Smart Home System Based on GSM Network

    Directory of Open Access Journals (Sweden)

    Bakhtiar Ali Karim

    2018-04-01

    Full Text Available Due to increasing robbery and intrusion, establishing home-security system has become a correlated part of the modern houses, buildings, and offices. As the family members are not at home all the time, the traditional home security system, which makes alarm sound only, may not be efficient enough. Alternatively, Global System for Mobile communications (GSM based security system can provide higher level of security and convenience compared to the traditionally used systems. The main objective of the current paper is to design and implement cost-efficient and reliable security, safety and home automation system for protection and occupants’ convenience. If any undesired events, such as intrusion, gas leakage and fire occurs in the house, our system warns the homeowner in real-time using Short Message Service (SMS. With the proposed system home appliances can also be controlled in three ways, namely sending SMS from the authorized numbers to the system through GSM network, smartphone app using Bluetooth module and infrared (IR control using IR module

  5. Application of smart technology in monitoring and control of home appliances

    Directory of Open Access Journals (Sweden)

    A. A. Abdulrazaq

    2017-08-01

    Full Text Available The inherent dependency of home appliances on human for monitoring and control has been found to be mainly responsible for power wastage, and increase in the rate of wear and tear, which invariably implies additional spending on the part of owners. The smart technology provides a way out. This paper presents an automated system which is based on arduino and android device for monitoring and controlling appliances to prevent the wastage of power. The system design is based on the Microcontroller MIKRO-C software, active sensors and wireless internet services which is used in different monitoring and control processes of fan, air-conditioner, light and heater. The system when tested performs efficiently in monitoring and controlling through switching the appliances in the room based on human presence and environmental changes due to light intensity and temperature variation.

  6. CERN GSM monitoring system

    CERN Multimedia

    Ghabrous Larrea, C

    2009-01-01

    As a result of the tremendous development of GSM services over the last years, the number of related services used by organizations has drastically increased. Therefore, monitoring GSM services is becoming a business critical issue in order to be able to react appropriately in case of incident. In order to provide with GSM coverage all the CERN underground facilities, more than 50 km of leaky feeder cable have been deployed. This infrastructure is also used to propagate VHF radio signals for the CERN’s fire brigade. Even though CERN’s mobile operator monitors the network, it cannot guarantee the availability of GSM services, and for sure not VHF services, where signals are carried by the leaky feeder cable. So, a global monitoring system has become critical to CERN. In addition, monitoring this infrastructure will allow to characterize its behaviour over time, especially with LHC operation. Given that commercial solutions were not yet mature, CERN developed a system based on GSM probes and an application...

  7. Radiation monitoring system

    International Nuclear Information System (INIS)

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  8. A DISTRIBUTED SMART HOME ARTIFICIAL INTELLIGENCE SYSTEM

    DEFF Research Database (Denmark)

    Lynggaard, Per

    2013-01-01

    A majority of the research performed today explore artificial intelligence in smart homes by using a centralized approach where a smart home server performs the necessary calculations. This approach has some disadvantages that can be overcome by shifting focus to a distributed approach where...... the artificial intelligence system is implemented as distributed as agents running parts of the artificial intelligence system. This paper presents a distributed smart home architecture that distributes artificial intelligence in smart homes and discusses the pros and cons of such a concept. The presented...... distributed model is a layered model. Each layer offers a different complexity level of the embedded distributed artificial intelligence. At the lowest layer smart objects exists, they are small cheap embedded microcontroller based smart devices that are powered by batteries. The next layer contains a more...

  9. Alpha-monitoring system

    International Nuclear Information System (INIS)

    Dincklage, R.D. von

    1982-01-01

    A continuously operating and fast system for the monitoring of radiactive materials is outlined. Its application to nuclear technology particularly to reprocessing is emphasized. Using high-resolution α-ray spectrocopy and the gas-jet method for the rapid transportation of the radionuclides to the solid state detectors makes detection limits as low as 0.2 μg/cm 3 for Pu-239 feasible. (orig.)

  10. Nuclear reactor monitoring system

    International Nuclear Information System (INIS)

    Drummond, C.N.; Bybee, R.T.; Mason, F.L.; Worsham, H.J.

    1976-01-01

    The invention pertains to an improved monitoring system for the neutron flux in a nuclear reactor. It is proposed to combine neutron flux detectors, a thermoelement, and a background radiation detector in one measuring unit. The spatial arrangement of these elements is fixed with great exactness; they are enclosed by an elastic cover and are brought into position in the reactor with the aid of a bent tube. The arrangement has a low failure rate and is easy to maintain. (HP) [de

  11. RTP Radiation Monitoring System

    International Nuclear Information System (INIS)

    Alfred, S.L.; Mohd Fairus Abdul Farid; Ahmad Nabil Abdul Rahim; Nurhayati Ramli

    2015-01-01

    Radiation Monitoring System aiming to limiting dose exposed to personnel to the lowest level referring to the concept of ALARA (As Low As Reasonably Achievable). Atomic Energy Licensing (Basic Safety Radiation Protection) Regulation 2010 (Act 304) is a baseline to control employee and public radiation protection program and guideline, as well as to meet the requirement of the Occupational Safety and Health 1994 (Act 514). (author)

  12. A home monitoring program including real-time wireless home spirometry in idiopathic pulmonary fibrosis: a pilot study on experiences and barriers.

    Science.gov (United States)

    Moor, C C; Wapenaar, M; Miedema, J R; Geelhoed, J J M; Chandoesing, P P; Wijsenbeek, M S

    2018-05-29

    In idiopathic pulmonary fibrosis (IPF), home monitoring experiences are limited, not yet real-time available nor implemented in daily care. We evaluated feasibility and potential barriers of a new home monitoring program with real-time wireless home spirometry in IPF. Ten patients with IPF were asked to test this home monitoring program, including daily home spirometry, for four weeks. Measurements of home and hospital spirometry showed good agreement. All patients considered real-time wireless spirometry useful and highly feasible. Both patients and researchers suggested relatively easy solutions for the identified potential barriers regarding real-time home monitoring in IPF.

  13. Improving management and effectiveness of home blood pressure monitoring: a qualitative UK primary care study.

    Science.gov (United States)

    Grant, Sabrina; Greenfield, Sheila M; Nouwen, Arie; McManus, Richard J

    2015-11-01

    Self-monitoring blood pressure (SMBP) is becoming an increasingly prevalent practice in UK primary care, yet there remains little conceptual understanding of why patients with hypertension engage in self-monitoring. To identify psychological factors or processes prompting the decision to self-monitor blood pressure. A qualitative study of patients previously participating in a survey study about SMBP from four general practices in the West Midlands. Taped and transcribed in-depth interviews with 16 patients (6 currently monitoring, 2 used to self-monitor, and 8 had never self-monitored). Thematic analysis was undertaken. Three main themes emerged: 'self' and 'living with hypertension' described the emotional element of living with an asymptomatic condition; 'self-monitoring behaviour and medication' described overall views about self-monitoring, current practice, reasons for monitoring, and the impact on medication adherence; and 'the GP-patient transaction' described the power relations affecting decisions to self-monitor. Self-monitoring was performed by some as a protective tool against the fears of a silent but serious condition, whereas others self-monitor simply out of curiosity. People who self-monitored tended not to discuss this with their nurse or GP, partly due to perceiving minimal or no interest from their clinician about home monitoring, and partly due to fear of being prescribed additional medication. The decision to self-monitor appeared often to be an individual choice with no schedule or systems to integrate it with other medical care. Better recognition by clinicians that patients are self-monitoring, perhaps utilising the results in shared decision-making, might help integrate it into daily practice. © British Journal of General Practice 2015.

  14. System Control Device Electronics Smart Home Using Neural Networks

    Directory of Open Access Journals (Sweden)

    Safarul Ilham

    2017-06-01

    Full Text Available The use of information technology is very useful for today’s life and the next, where the human facilitated in doing a variety of activities in the life day to day. By the development of the existing allows people no longer do a job with difficulty. For that, it takes a system safety home using system technology Web-based and complete video streaming CCTV (video streaming a person can see the condition of his home whenever and wherever by using handphone, laptops and other tools are connected to the Internet network. This tool can facilitate someone in the monitor at home and control equipment the House as open and close and the lock the gate, turning on and off the lights so homeowners are no longer have to visit their home and fear the state of the House because fully security and control in the House was handled by the system. based on the above problems Writer try to design work system a tool that can control the simulation tools home using two Microcontroller is Attiny 2313 and Atmega16.

  15. Bulk laundry monitoring system

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Jain, Amit; Verma, Amit; Anilkumar, S.; Babu, D.A.R.; Sharma, D.N.; Rande, N.R.; Singh, B.N.

    2012-01-01

    Protective wear (like boiler suits, hand gloves etc.) is essential while handling radioactive material in plants/laboratories. During the course of work, it is quite possible that protective wear may get contaminated. These protective wears are packed in laundry bags and send to Decontamination Centre (DC). There is a need for monitoring the laundry bags at the time of receipt, as well as before dispatch to respective locations to comply with AERB guidelines, To avoid cross contamination during wash cycle, contaminated bags (> 0.5 mR/h on surface) need to be segregated. Present paper describes the development of such system for monitoring surface dose rate on bags at the time of receipt. The system installed at ETP after calibration, effectively segregates the contaminated bags from the rest and prevents from cross contamination during wash cycle. Reduction in man-rem consumption due to semi automatic monitoring. Improved sensitivity due to good geometry, long counting time, background and attenuation corrections. Optimum utilization of decontamination chemicals based on level of contamination and keeping track of its inventory. Generation of decontamination process data base for improvement

  16. WIRELESS HOME AUTOMATION SYSTEM BASED ON MICROCONTROLLER

    Directory of Open Access Journals (Sweden)

    MUNA H. SALEH

    2017-11-01

    Full Text Available This paper presents the development of Global System Mobile (GSM-based control home air-conditioner for home automation system. The main aim of the prototype development is to reduce electricity wastage. GSM module was used for receiving Short Message Service (SMS from the user’s mobile phone that automatically enable the controller to take any further action such as to switch ON and OFF the home air-conditioner. The system controls the air-conditioner based on the temperature reading through the sensor. Every period temperature sensor sends the degree to Micro Controller Unit (MCU through ZigBee. Based on temperature degree MCU send ON or OFF signal to switch. Additionally, system allows user to operate or shut down the airconditioner remotely through SMS.

  17. Consumer Acceptance Analysis of the Home Energy Management System

    Directory of Open Access Journals (Sweden)

    Eung-Suk Park

    2017-12-01

    Full Text Available The purpose of this paper is to study consumer acceptance of the Home Energy Management System, which is the next generation electronic management system that the Korean government plans to implement in households. The Home Energy Management System is a critical device in maximizing the efficiency of electric energy consumption for each household by using a smart grid. Because it can visualize real-time price information on the electricity, households can easily monitor and control the amount of electricity consumption. With this feature, the Home Energy Management System can contribute to consumers’ total energy savings. This is a major reason why the Korean government wishes to implement it nationwide. Since the Home Energy Management System is a product that applies new technology that has not yet been directly encountered by consumers, there may be a difference in the level of public perception of the Home Energy Management System. Therefore, the impact of consumers’ awareness of the Home Energy Management System on their intention to use is important. To do this, the Technology Acceptance Model is utilized in this study. Traditional research on the Technology Acceptance Model includes awareness of usefulness and ease of use as well as intention to use. In contrast, in this research, an extended Technology Acceptance Model with four additional factors—economic benefit, social contribution, environmental responsibility, and innovativeness—that may affect the consumer’s awareness of usefulness and ease of use, is proposed. To collect the data, the survey was conducted with 287 respondents. As a result, the proposed model proved to be suitable in explaining the intention to use with a 70.3% explanation power. It is found that economic benefit (0.231 and innovativeness (0.259 impact on usefulness of the Home Energy Management System. Moreover, usefulness (0.551 has a bigger effect on intention to use than ease of use (0.338 does. Based

  18. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  19. Induced Seismicity Monitoring System

    Science.gov (United States)

    Taylor, S. R.; Jarpe, S.; Harben, P.

    2014-12-01

    There are many seismological aspects associated with monitoring of permanent storage of carbon dioxide (CO2) in geologic formations. Many of these include monitoring underground gas migration through detailed tomographic studies of rock properties, integrity of the cap rock and micro seismicity with time. These types of studies require expensive deployments of surface and borehole sensors in the vicinity of the CO2 injection wells. Another problem that may exist in CO2 sequestration fields is the potential for damaging induced seismicity associated with fluid injection into the geologic reservoir. Seismic hazard monitoring in CO2 sequestration fields requires a seismic network over a spatially larger region possibly having stations in remote settings. Expensive observatory-grade seismic systems are not necessary for seismic hazard deployments or small-scale tomographic studies. Hazard monitoring requires accurate location of induced seismicity to magnitude levels only slightly less than that which can be felt at the surface (e.g. magnitude 1), and the frequencies of interest for tomographic analysis are ~1 Hz and greater. We have developed a seismo/acoustic smart sensor system that can achieve the goals necessary for induced seismicity monitoring in CO2 sequestration fields. The unit is inexpensive, lightweight, easy to deploy, can operate remotely under harsh conditions and features 9 channels of recording (currently 3C 4.5 Hz geophone, MEMS accelerometer and microphone). An on-board processor allows for satellite transmission of parameter data to a processing center. Continuous or event-detected data is kept on two removable flash SD cards of up to 64+ Gbytes each. If available, data can be transmitted via cell phone modem or picked up via site visits. Low-power consumption allows for autonomous operation using only a 10 watt solar panel and a gel-cell battery. The system has been successfully tested for long-term (> 6 months) remote operations over a wide range

  20. Design and implementation of modular home security system with short messaging system

    Directory of Open Access Journals (Sweden)

    Budijono Santoso

    2014-03-01

    Full Text Available Today we are living in 21st century where crime become increasing and everyone wants to secure they asset at their home. In that situation user must have system with advance technology so person do not worry when getting away from his home. It is therefore the purpose of this design to provide home security device, which send fast information to user GSM (Global System for Mobile mobile device using SMS (Short Messaging System and also activate - deactivate system by SMS. The Modular design of this Home Security System make expandable their capability by add more sensors on that system. Hardware of this system has been designed using microcontroller AT Mega 328, PIR (Passive Infra Red motion sensor as the primary sensor for motion detection, camera for capturing images, GSM module for sending and receiving SMS and buzzer for alarm. For software this system using Arduino IDE for Arduino and Putty for testing connection programming in GSM module. This Home Security System can monitor home area that surrounding by PIR sensor and sending SMS, save images capture by camera, and make people panic by turn on the buzzer when trespassing surrounding area that detected by PIR sensor. The Modular Home Security System has been tested and succeed detect human movement.

  1. A new infusion pathway intactness monitoring system.

    Science.gov (United States)

    Ogawa, Hidekuni; Yonezawa, Yoshiharu; Maki, Hiromichi; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2006-01-01

    A new infusion pathway monitoring system has been developed for hospital and home use. The system consists of linear integrated circuits and a low-power 8-bit single chip microcomputer which constantly monitors the infusion pathway intactness. An AC (alternating current) voltage is induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The induced AC voltage can be recorded by a main electrode wrapped around the infusion polyvinyl chloride tube. A reference electrode is wrapped on the electrode to monitor the AC voltage around the main electrode. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltages and alerts the nursing station, via the nurse call system or PHS (personal handy phone system).

  2. The Danish Marine Monitoring System

    DEFF Research Database (Denmark)

    Ærtebjerg, G.

    1997-01-01

    Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996.......Indeholder abstracts fra Workshop on Marine Monitoring Systems and Technology, Risø, 17-18 April 1996....

  3. Home blood-pressure monitoring in a hypertensive pregnant population.

    Science.gov (United States)

    Perry, H; Sheehan, E; Thilaganathan, B; Khalil, A

    2018-04-01

    The majority of patients with chronic or gestational hypertension do not develop pre-eclampsia. Home blood-pressure monitoring (HBPM) has the potential to offer a more accurate and acceptable means of monitoring hypertensive patients during pregnancy compared with traditional pathways of frequent outpatient monitoring. The aim of this study was to determine whether HBPM reduces visits to antenatal services and is safe in pregnancy. This was a case-control study of 166 hypertensive pregnant women, which took place at St George's Hospital, University of London. Inclusion criteria were: chronic hypertension, gestational hypertension or high risk of developing pre-eclampsia, no significant proteinuria (≤ 1+ proteinuria on dipstick testing) and normal biochemical and hematological markers. Exclusion criteria were maternal age  155 mmHg or diastolic blood pressure > 100 mmHg, significant proteinuria (≥ 2+ proteinuria on dipstick testing or protein/creatinine ratio > 30 mg/mmol), evidence of small-for-gestational age (estimated fetal weight < 10 th centile), signs of severe pre-eclampsia, significant mental health concerns or insufficient understanding of the English language. Pregnant women in the HBPM group were taught how to measure and record their blood pressure using a validated machine at home and attended every 1-2 weeks for assessment depending on clinical need. The control group was managed as per the local protocol prior to the implementation of HBPM. The two groups were compared with respect to number of visits to antenatal services and outcome. There were 108 women in the HBPM group and 58 in the control group. There was no difference in maternal age, parity, body mass index, ethnicity or smoking status between the groups, but there were more women with chronic hypertension in the HBPM group compared with the control group (49.1% vs 25.9%, P = 0.004). The HBPM group had significantly fewer outpatient attendances per patient (6

  4. Storage monitoring system - 1997

    International Nuclear Information System (INIS)

    Mickelsen, B.; Nilsen, C.; Kinzel, R.; Davidson, B.; Pollock, R.

    1999-01-01

    Sandia National Laboratories has several ongoing projects in the area of nuclear materials management. These projects establish a core capability in monitoring stored nuclear materials. The overarching goal of these projects is to get the right sensor information to the right user to enhance the safety, security and to verify the legitimacy of use 1 of stored nuclear materials. An effort has been initiated to merge these projects into a common system. This paper provides an overview of several of these projects and the integration activities between them. (author)

  5. Storage monitoring system - 1997

    International Nuclear Information System (INIS)

    Mickelsen, B.; Nilsen, C.; Kinzel, R.; Davidson, B.; Pollock, R.

    1997-01-01

    Sandia National Laboratories has several ongoing projects in the area of nuclear materials management. These projects establish a core capability in monitoring stored nuclear materials. The overarching goal of these projects is to get the right sensor information to the right user to enhance the safety, security and to verify the legitimacy of use of stored nuclear materials. An effort has been initiated to merge these projects into a common system. This paper provides an overview of several of these projects and the integration activities between them

  6. Airborne monitoring system

    International Nuclear Information System (INIS)

    Kadmon, Y.; Gabovitch, A.; Tirosh, D.; Ellenbogen, M.; Mazor, T.; Barak, D.

    1997-01-01

    A complete system for tracking, mapping, and performing a composition analysis of a radioactive plume and contaminated area was developed at the NRCN. The system includes two major units : An airborne unit for monitoring and a ground station for analyzing. The airborne unit is mounted on a helicopter and includes file following. Four radiation sensor, two 2'' x 2'' Nal (Tl) sensors horizontally separated by lead shield for mapping and spectroscopy, and two Geiger Mueller (GM) tubes as part of the safety system. A multichannel analyzer card is used for spectroscopy. A navigation system, based on GPS and a barometric altitude meter, is used to locate the plume or ground data. The telemetry system, consisting of a transceiver and a modem, transfers all the data in real time to the ground station. An industrial PC (Field Works) runs a dedicated C++ Windows application to manage the acquired data. An independent microprocessor based backup system includes a recorder, display, and key pad. The ground station is based on an industrial PC, a telemetry system, a color printer and a modem to communicate with automatic meteorology stations in the relevant area. A special software controls the ground station. Measurement results are analyzed in the ground station to estimate plume parameters including motion, location, size, velocity, and perform risk assessment. (authors)

  7. Usability Problems in a Home Telemedicine System

    DEFF Research Database (Denmark)

    Bruun, Anders; Stage, Jan

    2010-01-01

    a high level of usability in order to enable their users to employ the required functionality, especially if the target user group is elderly people. This paper reports from a usability evaluation of a home telemedicine system. Five elderly persons carried out specified tasks with the system, and based...... on that we identified usability problems with the system. The problems are presented, analysed in relation to 12 different usability themes and related to results from other evaluations of similar systems....

  8. The Effect of the Transition to Home Monitoring for the Diagnosis of OSAS on Test Availability, Waiting Time, Patients’ Satisfaction, and Outcome in a Large Health Provider System

    Directory of Open Access Journals (Sweden)

    Ahmad Safadi

    2014-01-01

    Full Text Available During 2009, the Haifa district of Clalit Health Services (CHS has switched from in-lab polysomnography (PSG to home studies for the diagnosis of obstructive sleep apnea (OSA. We assessed the effects of this change on accessibility, waiting time, satisfaction, costs, and CPAP purchase by the patients. Data regarding sleep studies, CPAP purchase, and waiting times were collected retrospectively from the computerized database of CHS. Patients’ satisfaction was assessed utilizing a telephone questionnaire introduced to a randomized small sample of 70 patients. Comparisons were made between 2007 and 2008 (in-lab PSGs and 2010 and 2011 (when most studies were ambulatory. Of about 650000 insured individuals in the Haifa district of CHS, 1471 sleep studies were performed during 2007-2008 compared to 2794 tests during 2010-2011. The average waiting time was 9.9 weeks in 2007-2008 compared to 1.1 weeks in 2010-2011 (P<0.05. 597 CPAPs were purchased in 2007-2008 compared to 831 in 2010-2011. The overall patients’ satisfaction was similar, but discomfort tended to be higher in the in-laboratory group (4.1 vs 2.7 in a scale of 0–10; P=0.11. Switching to ambulatory diagnosis improved the test accessibility and reduced the waiting times. Patients’ satisfaction remained similarly high. The total direct cost of OSA management was reduced.

  9. Designing of smart home automation system based on Raspberry Pi

    Energy Technology Data Exchange (ETDEWEB)

    Saini, Ravi Prakash; Singh, Bhanu Pratap [B K Birla Institute of Engineering & Technology, Pilani, Rajasthan (India); Sharma, Mahesh Kumar; Wattanawisuth, Nattapol; Leeprechanon, Nopbhorn, E-mail: Dr.N.L@ieee.org [Thammasat University, Rangsit Campus, Pathum Thani (Thailand)

    2016-03-09

    Locally networked or remotely controlled home automation system becomes a popular paradigm because of the numerous advantages and is suitable for academic research. This paper proposes a method for an implementation of Raspberry Pi based home automation system presented with an android phone access interface. The power consumption profile across the connected load is measured accurately through programming. Users can access the graph of total power consumption with respect to time worldwide using their Dropbox account. An android application has been developed to channelize the monitoring and controlling operation of home appliances remotely. This application facilitates controlling of operating pins of Raspberry Pi by pressing the corresponding key for turning “on” and “off” of any desired appliance. Systems can range from the simple room lighting control to smart microcontroller based hybrid systems incorporating several other additional features. Smart home automation systems are being adopted to achieve flexibility, scalability, security in the sense of data protection through the cloud-based data storage protocol, reliability, energy efficiency, etc.

  10. Designing of smart home automation system based on Raspberry Pi

    Science.gov (United States)

    Saini, Ravi Prakash; Singh, Bhanu Pratap; Sharma, Mahesh Kumar; Wattanawisuth, Nattapol; Leeprechanon, Nopbhorn

    2016-03-01

    Locally networked or remotely controlled home automation system becomes a popular paradigm because of the numerous advantages and is suitable for academic research. This paper proposes a method for an implementation of Raspberry Pi based home automation system presented with an android phone access interface. The power consumption profile across the connected load is measured accurately through programming. Users can access the graph of total power consumption with respect to time worldwide using their Dropbox account. An android application has been developed to channelize the monitoring and controlling operation of home appliances remotely. This application facilitates controlling of operating pins of Raspberry Pi by pressing the corresponding key for turning "on" and "off" of any desired appliance. Systems can range from the simple room lighting control to smart microcontroller based hybrid systems incorporating several other additional features. Smart home automation systems are being adopted to achieve flexibility, scalability, security in the sense of data protection through the cloud-based data storage protocol, reliability, energy efficiency, etc.

  11. Designing of smart home automation system based on Raspberry Pi

    International Nuclear Information System (INIS)

    Saini, Ravi Prakash; Singh, Bhanu Pratap; Sharma, Mahesh Kumar; Wattanawisuth, Nattapol; Leeprechanon, Nopbhorn

    2016-01-01

    Locally networked or remotely controlled home automation system becomes a popular paradigm because of the numerous advantages and is suitable for academic research. This paper proposes a method for an implementation of Raspberry Pi based home automation system presented with an android phone access interface. The power consumption profile across the connected load is measured accurately through programming. Users can access the graph of total power consumption with respect to time worldwide using their Dropbox account. An android application has been developed to channelize the monitoring and controlling operation of home appliances remotely. This application facilitates controlling of operating pins of Raspberry Pi by pressing the corresponding key for turning “on” and “off” of any desired appliance. Systems can range from the simple room lighting control to smart microcontroller based hybrid systems incorporating several other additional features. Smart home automation systems are being adopted to achieve flexibility, scalability, security in the sense of data protection through the cloud-based data storage protocol, reliability, energy efficiency, etc.

  12. Plant monitor system

    International Nuclear Information System (INIS)

    Scarola, K.; Jamison, D.; Manazir, R.; Rescori, R.; Harmon, D.

    1991-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system which is nuclear qualified for rapid response to changes in plant parameters and a component control system which together provide a discrete monitoring and control capability at a panel in the control room. A separate data processing system, which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs and a large, overhead integrated process status overview board. The discrete indicator and alarm system and the data processing system receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the main machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof. (author)

  13. Wireless remote monitoring system for sleep apnea

    Science.gov (United States)

    Oh, Sechang; Kwon, Hyeokjun; Varadan, Vijay K.

    2011-04-01

    Sleep plays the important role of rejuvenating the body, especially the central nervous system. However, more than thirty million people suffer from sleep disorders and sleep deprivation. That can cause serious health consequences by increasing the risk of hypertension, diabetes, heart attack and so on. Apart from the physical health risk, sleep disorders can lead to social problems when sleep disorders are not diagnosed and treated. Currently, sleep disorders are diagnosed through sleep study in a sleep laboratory overnight. This involves large expenses in addition to the inconvenience of overnight hospitalization and disruption of daily life activities. Although some systems provide home based diagnosis, most of systems record the sleep data in a memory card, the patient has to face the inconvenience of sending the memory card to a doctor for diagnosis. To solve the problem, we propose a wireless sensor system for sleep apnea, which enables remote monitoring while the patient is at home. The system has 5 channels to measure ECG, Nasal airflow, body position, abdominal/chest efforts and oxygen saturation. A wireless transmitter unit transmits signals with Zigbee and a receiver unit which has two RF modules, Zigbee and Wi-Fi, receives signals from the transmitter unit and retransmits signals to the remote monitoring system with Zigbee and Wi-Fi, respectively. By using both Zigbee and Wi-Fi, the wireless sensor system can achieve a low power consumption and wide range coverage. The system's features are presented, as well as continuous monitoring results of vital signals.

  14. Home-based mobile cardio-pulmonary rehabilitation consultant system.

    Science.gov (United States)

    Lee, Hsu-En; Wang, Wen-Chih; Lu, Shao-Wei; Wu, Bo-Yuan; Ko, Li-Wei

    2011-01-01

    Cardiovascular diseases are the most popular cause of death in the world recently. For postoperatives, cardiac rehabilitation is still asked to maintain at home (phase II) to improve cardiac function. However, only one third of outpatients do the exercise regularly, reflecting the difficulty for home-based healthcare: lacking of monitoring and motivation. Hence, a cardio-pulmonary rehabilitation system was proposed in this research to improve rehabilitation efficiency for better prognosis. The proposed system was built on mobile phone and receiving electrocardiograph (ECG) signal from a wireless ECG holter via Bluetooth connection. Apart from heart rate (HR) monitor, an ECG derived respiration (EDR) technique is also included to provide respiration rate (RR). Both HR and RR are the most important vital signs during exercise but only used one physiological signal recorder in this system. In clinical test, there were 15 subjects affording Bruce Task (treadmill) to simulate rehabilitation procedure. Correlation between this system and commercial product (Custo-Med) was up to 98% in HR and 81% in RR. Considering the prevention of sudden heart attack, an arrhythmia detection expert system and healthcare server at the backend were also integrated to this system for comprehensive cardio-pulmonary monitoring whenever and wherever doing the exercise.

  15. Efficient Active Sensing with Categorized Further Explorations for a Home Behavior-Monitoring Robot

    Directory of Open Access Journals (Sweden)

    Wenwei Yu

    2017-01-01

    Full Text Available Mobile robotics is a potential solution to home behavior monitoring for the elderly. For a mobile robot in the real world, there are several types of uncertainties for its perceptions, such as the ambiguity between a target object and the surrounding objects and occlusions by furniture. The problem could be more serious for a home behavior-monitoring system, which aims to accurately recognize the activity of a target person, in spite of these uncertainties. It detects irregularities and categorizes situations requiring further explorations, which strategically maximize the information needed for activity recognition while minimizing the costs. Two schemes of active sensing, based on two irregularity detections, namely, heuristic-based and template-matching-based irregularity detections, were implemented and examined for body contour-based activity recognition. Their time cost and accuracy in activity recognition were evaluated through experiments in both a controlled scenario and a home living scenario. Experiment results showed that the categorized further explorations guided the robot system to sense the target person actively. As a result, with the proposed approach, the robot system has achieved higher accuracy of activity recognition.

  16. Management of Uncertainty and Spatio-Temporal Aspects for Monitoring and Diagnosis in a Smart Home

    Directory of Open Access Journals (Sweden)

    Juan Carlos Augusto

    2008-12-01

    Full Text Available The health system in developed countries is facing a problem of scalability in order to accommodate the increased proportion of the elderly population. Scarce resources cannot be sustained unless innovative technology is considered to provide health care in a more effective way. The Smart Home provides pre- ventive and assistive technology to vulnerable sectors of the population. Much research and development has been focused on the technological side (e.g., sensors and networks but less effort has been invested in the capability of the Smart Home to intelligently monitor situations of interest and act in the best in- terest of the occupants. In this article we model a Smart Home scenario, using knowledge in the form of Event-Condition-Action rules together with a new inference scheme which incorporates spatio-temporal reasoning and uncertainty. A reasoning system called RIMER, has been extended to permit the monitoring of situations according to the place where they occur and the specific order and duration of the activities. The system allows for the specification of uncertainty both in terms of knowledge representation and credibility of the conclusions that can be achieved in terms of the evidence available.

  17. Home Environment Service Knowledge Management System

    DEFF Research Database (Denmark)

    Zhang, Jiang; Rossello Busquet, Ana; Soler, José

    2011-01-01

    This paper makes three contributions to assist households to control their home devices in an easy way and to simplify the software installation and configuration processes across multi-vendor environments. First, a Home Environment Service Knowledge Management System is proposed, which is based...... on the knowledge implemented by ontology and uses the inference function of reasoner to find out available software services according to household requests. Second, this paper provides a concrete methodology to exploit and acquire conflict-free information from ontology knowledge by using a reasoner. At last......, a strategy of calculating the sequence of service dependency hierarchy is proposed by this paper....

  18. A Scoping Review of Economic Evaluations Alongside Randomised Controlled Trials of Home Monitoring in Chronic Disease Management.

    Science.gov (United States)

    Kidholm, Kristian; Kristensen, Mie Borch Dahl

    2018-04-01

    Many countries have considered telemedicine and home monitoring of patients as a solution to the demographic challenges that health-care systems face. However, reviews of economic evaluations of telemedicine have identified methodological problems in many studies as they do not comply with guidelines. The aim of this study was to examine economic evaluations alongside randomised controlled trials of home monitoring in chronic disease management and hereby to explore the resources included in the programme costs, the types of health-care utilisation that change as a result of home monitoring and discuss the value of economic evaluation alongside randomised controlled trials of home monitoring on the basis of the studies identified. A scoping review of economic evaluations of home monitoring of patients with chronic disease based on randomised controlled trials and including information on the programme costs and the costs of equipment was carried out based on a Medline (PubMed) search. Nine studies met the inclusion criteria. All studies include both costs of equipment and use of staff, but there is large variation in the types of equipment and types of tasks for the staff included in the costs. Equipment costs constituted 16-73% of the total programme costs. In six of the nine studies, home monitoring resulted in a reduction in primary care or emergency contacts. However, in total, home monitoring resulted in increased average costs per patient in six studies and reduced costs in three of the nine studies. The review is limited by the small number of studies found and the restriction to randomised controlled trials, which can be problematic in this area due to lack of blinding of patients and healthcare professionals and the difficulty of implementing organisational changes in hospital departments for the limited period of a trial. Furthermore, our results may be based on assessments of older telemedicine interventions.

  19. A Novel Web Service Based Home Energy Management System

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Soler, José

    2011-01-01

    and optimize the energy consumption in home environments. The main element of HEMS is the home gateway. In this paper, a home gateway suitable for HEMS is presented. The home gateway proposed uses rules to implement the home energy management system. The rules can be downloaded though web services from a rule...... server. Furthermore, web services are used to provide modularity to the home gateway by enabling the deployment of the different logical components into different devices, if necessary....

  20. Waste monitoring system for effluents

    International Nuclear Information System (INIS)

    Macdonald, J.M.; Gomez, B.; Trujillo, L.; Malcom, J.E.; Nekimken, H.; Pope, N.; Bibeau, R.

    1995-07-01

    The waste monitoring system in use at Los Alamos National Laboratory's Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system

  1. Design and Implementation of a WiFi Based Home Automation System

    OpenAIRE

    Ahmed ElShafee; Karim Alaa Hamed

    2012-01-01

    This paper presents a design and prototype implementation of new home automation system that uses WiFi technology as a network infrastructure connecting its parts. The proposed system consists of two main components; the first part is the server (web server), which presents system core that manages, controls, and monitors users- home. Users and system administrator can locally (LAN) or remotely (internet) manage and control system code. Second part is hardware interface m...

  2. Area monitoring intelligent system - SIMA

    International Nuclear Information System (INIS)

    Bhoem, P.; Hisas, F.; Gelardi, G.

    1990-01-01

    The area monitoring intelligent system (SIMA) is an equipment to be used in radioprotection. SIMA has the function of monitoring the radiation levels of determined areas of the installations where radioactive materials are handled. (Author) [es

  3. SQUID: sensorized shirt with smartphone interface for exercise monitoring and home rehabilitation.

    Science.gov (United States)

    Farjadian, Amir B; Sivak, Mark L; Mavroidis, Constantinos

    2013-06-01

    Stroke is a leading cause of serious long-term disability in the United States. There is a need for new technological adjuncts to expedite patients' scheduled discharge from hospital and pursue rehabilitation procedure at home. SQUID is a low-cost, smart shirt that incorporates a six-channel electromyography (EMG) and heart rate data acquisition module to deliver objective audiovisual and haptic biofeedback to the patient. The sensorized shirt is interfaced with a smartphone application, for the subject's usage at home, as well as the online database, for the therapist's remote supervision from hospital. A single healthy subject was recruited to investigate the system functionality during improperly performed exercise. The system can potentially be used in automated, remote monitoring of variety of physical therapy exercises, rooted in strength or coordination training of specific muscle groups.

  4. The application of autostereoscopic display in smart home system based on mobile devices

    Science.gov (United States)

    Zhang, Yongjun; Ling, Zhi

    2015-03-01

    Smart home is a system to control home devices which are more and more popular in our daily life. Mobile intelligent terminals based on smart homes have been developed, make remote controlling and monitoring possible with smartphones or tablets. On the other hand, 3D stereo display technology developed rapidly in recent years. Therefore, a iPad-based smart home system adopts autostereoscopic display as the control interface is proposed to improve the userfriendliness of using experiences. In consideration of iPad's limited hardware capabilities, we introduced a 3D image synthesizing method based on parallel processing with Graphic Processing Unit (GPU) implemented it with OpenGL ES Application Programming Interface (API) library on IOS platforms for real-time autostereoscopic displaying. Compared to the traditional smart home system, the proposed system applied autostereoscopic display into smart home system's control interface enhanced the reality, user-friendliness and visual comfort of interface.

  5. A HOME-BASED MASSED PRACTICE SYSTEM FOR PEDIATRIC NEUROREHABILITATION

    Directory of Open Access Journals (Sweden)

    Yi-Ning Wu

    2013-11-01

    Full Text Available The objective of this paper is to introduce a novel low-cost human-computer interface (HCI system for home-based massed practice for children with upper limb impairment due to brain injury. Successful massed practice, a type of neurorehabilitation, may be of value for children with brain injury because it facilitates impaired limb use. Use of automated, home-based systems could provide a practical means for massed practice. However, the optimal strategy to deliver and monitor home-based massed practice is still unclear. We integrated motion sensor, video game, and HCI software technologies to create a useful home-based massed practice at targeted joints. The system records joint angle and number of movements using a low-cost custom hand-held sensor. The sensor acts as an input device to play video games. We demonstrated the system’s functionality and provided preliminary observations on usage by children with brain injury, including joint motion and muscle activation.

  6. Ubiquitous Smart Home System Using Android Application

    OpenAIRE

    Kumar, Shiu

    2014-01-01

    This paper presents a flexible standalone, low-cost smart home system, which is based on the Android app communicating with the micro-web server providing more than the switching functionalities. The Arduino Ethernet is used to eliminate the use of a personal computer (PC) keeping the cost of the overall system to a minimum while voice activation is incorporated for switching functionalities. Devices such as light switches, power plugs, temperature sensors, humidity sensors, current sensors, ...

  7. Commercial dissemination approaches for solar home systems

    Energy Technology Data Exchange (ETDEWEB)

    Terrado, E.

    1997-12-01

    The author discusses the issue of providing solar home systems to primarily rural areas from the perspective of how to commercialize the process. He considers two different approaches, one an open market approach and the other an exclusive market approach. He describes examples of the exclusive market approach which are in process in Argentina and Brazil. Coming from a banking background, the business aspects are discussed in detail. He points out the strengths and weaknesses of both approaches toward developing such systems.

  8. Unobtrusive Detection of Mild Cognitive Impairment in Older Adults Through Home Monitoring*

    Science.gov (United States)

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2016-01-01

    The early detection of dementias such as Alzheimer’s disease can in some cases reverse, stop or slow cognitive decline and in general greatly reduce the burden of care. This is of increasing significance as demographic studies are warning of an aging population in North America and worldwide. Various smart homes and systems have been developed to detect cognitive decline through continuous monitoring of high risk individuals. However, the majority of these smart homes and systems use a number of predefined heuristics to detect changes in cognition, which has been demonstrated to focus on the idiosyncratic nuances of the individual subjects and thus does not generalize. In this paper, we address this problem by building generalized linear models of home activity of subjects monitored using unobtrusive sensing technologies. We use inhomogenous Poisson processes to model the presence of subjects within different rooms throughout the day. We employ an information theoretic approach to compare the activity distributions learned, and we observe significant statistical differences between the cognitively intact and impaired subjects. Using a simple thresholding approach, we were able to detect mild cognitive impairment in older adults with an average area under the ROC curve of 0.716 and an average area under the precision-recall curve of 0.706 using distributions estimated over time windows of 12 weeks. PMID:26841424

  9. Unobtrusive Detection of Mild Cognitive Impairment in Older Adults Through Home Monitoring.

    Science.gov (United States)

    Akl, Ahmad; Snoek, Jasper; Mihailidis, Alex

    2017-03-01

    The early detection of dementias such as Alzheimer's disease can in some cases reverse, stop, or slow cognitive decline and in general greatly reduce the burden of care. This is of increasing significance as demographic studies are warning of an aging population in North America and worldwide. Various smart homes and systems have been developed to detect cognitive decline through continuous monitoring of high risk individuals. However, the majority of these smart homes and systems use a number of predefined heuristics to detect changes in cognition, which has been demonstrated to focus on the idiosyncratic nuances of the individual subjects, and thus, does not generalize. In this paper, we address this problem by building generalized linear models of home activity of older adults monitored using unobtrusive sensing technologies. We use inhomogenous Poisson processes to model the presence of the recruited older adults within different rooms throughout the day. We employ an information theoretic approach to compare the generalized linear models learned, and we observe significant statistical differences between the cognitively intact and impaired older adults. Using a simple thresholding approach, we were able to detect mild cognitive impairment in older adults with an average area under the ROC curve of 0.716 and an average area under the precision-recall curve of 0.706 using activity models estimated over a time window of 12 weeks.

  10. Environmental monitoring and information systems

    International Nuclear Information System (INIS)

    Gibbert, R.

    1998-01-01

    Environmental monitoring and information systems installed by Dornier are summarized. A broad spectrum of environmental areas from air quality and water to radioactivity is covered. Nuclear power plant monitoring systems, either as remote or plant-internal monitoring systems, form an important element of the work undertaken. The systems delivered covered local, regional or national areas. The range of services provided, and hardware and software platforms are listed. (R.P.)

  11. Evaluating penetration-monitoring systems

    International Nuclear Information System (INIS)

    Markin, J.T.

    1981-01-01

    Evaluating the performance of a process monitoring system in detecting improper activities that could be related to material diversion requires a framework for addressing the complexity and statistical uncertainty of such systems. This report proposes a methodology that determines the optimal divertor strategy against a monitoring system and the system probability of detection. This method extends previous work by correctly modeling uncorrelated and correlated measurement errors for radiation monitors

  12. Automatic Battery Swap System for Home Robots

    Directory of Open Access Journals (Sweden)

    Juan Wu

    2012-12-01

    Full Text Available This paper presents the design and implementation of an automatic battery swap system for the prolonged activities of home robots. A battery swap station is proposed to implement battery off-line recharging and on-line exchanging functions. It consists of a loading and unloading mechanism, a shifting mechanism, a locking device and a shell. The home robot is a palm-sized wheeled robot with an onboard camera and a removable battery case in the front. It communicates with the battery swap station wirelessly through ZigBee. The influences of battery case deflection and robot docking deflection on the battery swap operations have been investigated. The experimental results show that it takes an average time of 84.2s to complete the battery swap operations. The home robot does not have to wait several hours for the batteries to be fully charged. The proposed battery swap system is proved to be efficient in home robot applications that need the robots to work continuously over a long period.

  13. Economics of Home Monitoring for Apnea in Late Preterm Infants.

    Science.gov (United States)

    Montenegro, Brian L; Amberson, Michael; Veit, Lauren; Freiberger, Christina; Dukhovny, Dmitry; Rhein, Lawrence M

    2017-01-01

    Apnea of prematurity affects a small proportion but large absolute number of late preterm infants, with out-patient management variably utilized despite relative clinical equipoise and potential for improved cost-effectiveness. Over a 5-y period, from 2009 to 2013, infants born at ≥34 weeks gestational age at a level IIIB academic center in Boston, Massachusetts, with discharge-delaying apnea, bradycardia, and desaturation (ABD) events were identified. In-patient costs for discharge-delaying ABD events were compared with hypothetical out-patient management. Out-patient costs took into account 4-10 d of in-patient observation for ABD events before caffeine initiation, 3-5 d of additional in-patient observation before discharge, daily caffeine until 43 weeks corrected gestational age, home pulse oximetry monitoring until 44 weeks corrected gestational age, and consideration of variable readmission rates ranging from 0 to 10%. A total of 425 late preterm and term infants were included in our analysis. Utilization of hypothetical out-patient management resulted in cost savings per eligible patient ranging from $2,422 to $62, dependent upon variable periods of in-patient observation. Sensitivity analysis demonstrated few instances of decreased relative cost-effectiveness. Out-patient management of discharge-delaying ABD events in a late preterm and term population was a cost-effective alternative to prolonged in-patient observation. Copyright © 2017 by Daedalus Enterprises.

  14. An inexpensive particle monitor for smoker behaviour modification in homes.

    Science.gov (United States)

    Semple, Sean; Apsley, Andrew; Maccalman, Laura

    2013-09-01

    To compare the response of a new particle counting instrument (Dylos DC1700) with that produced by a device (TSI Sidepak Personal Aerosol Monitor AM510) commonly used to measure PM2.5 in settings where secondhand smoke (SHS) is encountered. Controlled chamber experiments with different SHS concentrations were generated by burning a cigarette for varying time periods and running both devices simultaneously. The Dylos and Sidepak devices produced similar responses to changes in SHS concentrations up to 1000 μg/m(3). Using 591 min of contemporaneous measurements from 13 chamber experiments, an equation was developed to allow conversion of particle number concentration data from the Dylos to estimated mass concentration data for SHS aerosol. The Dylos DC1700 can provide real-time data that may be converted to an estimate of SHS levels in smoky environments. Given the low cost, low noise and simplicity of use, this device is likely to be a useful tool for interventions to provide feedback of SHS concentrations to help motivate changes in smoking behaviour at home.

  15. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  16. Passive in-home health and wellness monitoring: overview, value and examples.

    Science.gov (United States)

    Alwan, Majd

    2009-01-01

    Modern sensor and communication technology, coupled with advances in data analysis and artificial intelligence techniques, is causing a paradigm shift in remote management and monitoring of chronic disease. In-home monitoring technology brings the added benefit of measuring individualized health status and reporting it to the care provider and caregivers alike, allowing timely and targeted preventive interventions, even in home and community based settings. This paper presents a paradigm for geriatric care based on monitoring older adults passively in their own living settings through placing sensors in their living environments or the objects they use. Activity and physiological data can be analyzed, archived and mined to detect indicators of early disease onset or changes in health conditions at various levels. Examples of monitoring systems are discussed and results from field evaluation pilot studies are summarized. The approach has shown great promise for a significant value proposition to all the stakeholders involved in caring for older adults. The paradigm would allow care providers to extend their services into the communities they serve.

  17. Activity Learning as a Foundation for Security Monitoring in Smart Homes

    Directory of Open Access Journals (Sweden)

    Jessamyn Dahmen

    2017-03-01

    Full Text Available Smart environment technology has matured to the point where it is regularly used in everyday homes as well as research labs. With this maturation of the technology, we can consider using smart homes as a practical mechanism for improving home security. In this paper, we introduce an activity-aware approach to security monitoring and threat detection in smart homes. We describe our approach using the CASAS smart home framework and activity learning algorithms. By monitoring for activity-based anomalies we can detect possible threats and take appropriate action. We evaluate our proposed method using data collected in CASAS smart homes and demonstrate the partnership between activity-aware smart homes and biometric devices in the context of the CASAS on-campus smart apartment testbed.

  18. Activity Learning as a Foundation for Security Monitoring in Smart Homes.

    Science.gov (United States)

    Dahmen, Jessamyn; Thomas, Brian L; Cook, Diane J; Wang, Xiaobo

    2017-03-31

    Smart environment technology has matured to the point where it is regularly used in everyday homes as well as research labs. With this maturation of the technology, we can consider using smart homes as a practical mechanism for improving home security. In this paper, we introduce an activity-aware approach to security monitoring and threat detection in smart homes. We describe our approach using the CASAS smart home framework and activity learning algorithms. By monitoring for activity-based anomalies we can detect possible threats and take appropriate action. We evaluate our proposed method using data collected in CASAS smart homes and demonstrate the partnership between activity-aware smart homes and biometric devices in the context of the CASAS on-campus smart apartment testbed.

  19. Feasibility and usability of a home monitoring concept based on mobile phones and near field communication (NFC) technology.

    Science.gov (United States)

    Morak, Jürgen; Kollmann, Alexander; Schreier, Günter

    2007-01-01

    Utilization of mobile information and communication technologies in home monitoring applications is becoming more and more common. The mobile phone, acting as a patient terminal for patients suffering from chronic diseases, provides an active link to the caregiver to transmit health status information and receive feedback. In such a concept the usability is still limited by the necessity of entering the values via the mobile phone's small keypad. The near field communication technology (NFC), a touch-based wireless interface that became available recently, may improve the usability level of such applications significantly. The focus of this paper is to describe the development of a prototype application based on this technology embedded in a home monitoring system. The feasibility and usability of this approach are evaluated and compared with concepts used in previous approaches. The high quantifier with respect to overall usability indicates that NFC may be the technology of choice for some tasks in home monitoring applications.

  20. Life Support Systems: Environmental Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — The Advanced Exploration Systems (AES) Life Support Systems project Environmental Monitoring (EM) systems task objectives are to develop and demonstrate onboard...

  1. Ultrasonic monitoring system

    International Nuclear Information System (INIS)

    McLain, R.E.

    1975-01-01

    The ultrasonic monitoring system is used in LMFBR's, BWR's or PWR's. A remotely controlled, movable instrument carrier may be used which contains the piezo-electric transducer and is connected to the main control console by a transmission cable. An excitation pulse coming from a pulse generator is used to excite the transducer with a maximum of energy, independent of the length of the transmission line. Pulse width and pulse amplitude can be set without any direct interference into the transducer. For this purpose, a resistor whose impedance has been matched to that of the transmission line is connected to the input of the transmission line. Moreover, a capacitor for generation of the excitation pulse is coupled with the transmission line by means of a four-layer switching diode and is discharged. For termination of the excitation and the control pulses, respectively, another four-layer switching diode connected parallel to the capacitor quickly discharges the capacitor. The capacitor and the capacitance of the line constitute a voltage divider. In this way it is possible to change the length of the transmission line and, to safeguard the generation of a pulse of the desired amplitude, only vary the capacitance of the capacitor. (DG/RF) [de

  2. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  3. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  4. Kinect based physiotherapy system for home use

    Directory of Open Access Journals (Sweden)

    Haas Dominik

    2015-09-01

    Full Text Available In physiotherapy, rehabilitation outcome is majorly dependent on the patient continuing exercises at home. To support a continuous and correct execution of exercises composed by the physiotherapist it is important that the patient stays motivated. With the emergence of game consoles such as Nintendo Wii, Sony PlayStation or Microsoft Xbox360 that employ special controllers or camera based motion recognition as means of user input those technologies have also been found to be interesting for other real-life applications. We present a concept to employ the Microsoft Kinect system as means to support patients during physiotherapy exercises at home. The system is intended to allow a physiotherapist to compose an individual set of exercises and to control the correct execution of those exercises through tracking the patient’s motions.

  5. Novel Approach for Ensuring Increased Validity in Home Blood Pressure Monitoring

    DEFF Research Database (Denmark)

    Wagner, Stefan Rahr; Toftegaard, Thomas Skjødeberg; Bertelsen, Olav Wedege

    This paper proposes a novel technique to increase the validity of home blood pressure monitoring by using various sensor technologies as part of an intelligent environment platform in the home of the user. A range of recommendations exists on how to obtain a valid blood pressure but with the devi......This paper proposes a novel technique to increase the validity of home blood pressure monitoring by using various sensor technologies as part of an intelligent environment platform in the home of the user. A range of recommendations exists on how to obtain a valid blood pressure...

  6. Posture recognition based on fuzzy logic for home monitoring of the elderly.

    Science.gov (United States)

    Brulin, Damien; Benezeth, Yannick; Courtial, Estelle

    2012-09-01

    We propose in this paper a computer vision-based posture recognition method for home monitoring of the elderly. The proposed system performs human detection prior to the posture analysis; posture recognition is performed only on a human silhouette. The human detection approach has been designed to be robust to different environmental stimuli. Thus, posture is analyzed with simple and efficient features that are not designed to manage constraints related to the environment but only designed to describe human silhouettes. The posture recognition method, based on fuzzy logic, identifies four static postures and is robust to variation in the distance between the camera and the person, and to the person's morphology. With an accuracy of 74.29% of satisfactory posture recognition, this approach can detect emergency situations such as a fall within a health smart home.

  7. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  8. Service models for remote healthcare monitoring systems.

    Science.gov (United States)

    Moorman, Bridget A

    2010-01-01

    These scenarios reflect where the future is heading for remote health monitoring technology and service expectations. Being able to manage a "system of systems" with timely service hand-off over seams of responsibility and system interfaces will become very important for a BMET or clinical engineer. These interfaces will include patient homes, clinician homes, commercial/civilian infrastructure, public utilities, vendor infrastructure as well as internal departmental domains. Concurrently, technology is changing rapidly resulting in newer software delivery modes and hardware appliances as well as infrastructure changes. Those who are able to de-construct the complex systems and identify infrastructure assumptions and seams of servicing responsibility will be able to better understand and communicate the expectations for service of these systems. Moreover, as identified in Case 1, prodigious use of underlying system monitoring tools (managing the "meta-data") could move servicing of these remote systems from a reactive approach to a proactive approach. A prepared healthcare organization will identify their current and proposed future service combination use cases and design service philosophies and expectations for those use cases, while understanding the infrastructure assumptions and seams of responsibility. This is the future of technical service to the healthcare clinicians and patients.

  9. Plant monitoring system

    International Nuclear Information System (INIS)

    Tamaoki, Tetsuo.

    1994-01-01

    The memory means of the present invention memorize conditions for analyzing a sampling period for inputting process signals and time sequential data of the process signals. The process signals are analyzed following after sampling period and the analysis conditions stored in the memory means preceding to monitoring. A monitoring condition setting means controls and subsequently updates the sampling period and the analysis conditions in the memory means based on the analysis data, to finally set monitoring conditions. With such procedures, analysis conditions such as optimum analysis frequency range, signal sampling period and correlational characteristics between process noise signals are automatically selected. (I.S.)

  10. Wireless ZigBee home automation system

    Science.gov (United States)

    Craciunescu, Razvan; Halunga, Simona; Fratu, Octavian

    2015-02-01

    The home automation system concept existed for many years but in the last decade, due to the rapid development of sensors and wireless technologies, a large number of various such "intelligent homes" have been developed. The purpose of the present paper is to demonstrate the flexibility, reliability and affordability of home automation projects, based on a simple and affordable implementation. A wireless sensing and control system have been developed and tested, having a number of basic functionalities such as switching on/off the light according to ambient lighting and turning on/off the central heating. The system has been built around low power microcontrollers and ZigBee modems for wireless communication, using a set of Vishay 640 thermistor sensors for temperature measurements and Vishay LDR07 photo-resistor for humidity measurements. A trigger is activated when the temperature or light measurements are above/below a given threshold and a command is transmitted to the central unit through the ZigBee radio module. All the data processing is performed by a low power microcontroller both at the sensing device and at the control unit.

  11. Willingness of older adults to share data and privacy concerns after exposure to unobtrusive in-home monitoring.

    Science.gov (United States)

    Boise, Linda; Wild, Katherine; Mattek, Nora; Ruhl, Mary; Dodge, Hiroko H; Kaye, Jeffrey

    2013-01-01

    Older adult participants in the Intelligent Systems for Assessment of Aging Changes study (ISAAC) carried out by the Oregon Center for Aging and Technology (ORCATECH) were surveyed regarding their attitudes about unobtrusive home monitoring and computer use at baseline and after one year (n=119). The survey was part of a longitudinal study using in-home sensor technology to detect cognitive changes and other health problems. Our primary objective was to measure willingness to share health or activity data with one's doctor or family members and concerns about privacy or security of monitoring over one year of study participation. Differences in attitudes of participants with Mild Cognitive Impairment (MCI) compared to those with normal cognition were also examined. A high proportion (over 72%) of participants reported acceptance of in-home and computer monitoring and willingness to have data shared with their doctor or family members. However, a majority (60%) reported concerns related to privacy or security; these concerns increased after one year of participation. Few differences between participants with MCI and those with normal cognition were identified. Findings suggest that involvement in this unobtrusive in-home monitoring study may have raised awareness about the potential privacy risks of technology. Still, results show high acceptance, stable over time, of sharing information from monitoring systems with family members and doctors. Our findings have important implications for the deployment of technologies among older adults in research studies as well as in the general community.

  12. Home Automation and Security System Using Android ADK

    OpenAIRE

    Deepali Javale; Mohd. Mohsin; Shreerang Nandanwar; Mayur Shingate

    2013-01-01

    Today we are living in 21st century where automation is playing important role in human life. Home automation allows us to control household appliances like light, door, fan, AC etc. It also provides home security and emergency system to be activated. Home automation not only refers to reduce human efforts but also energy efficiency and time saving. The main objective of home automation and security is to help handicapped and old aged people which will enable them to control home appliances a...

  13. Networked Biomedical System for Ubiquitous Health Monitoring

    Directory of Open Access Journals (Sweden)

    Arjan Durresi

    2008-01-01

    Full Text Available We propose a distributed system that enables global and ubiquitous health monitoring of patients. The biomedical data will be collected by wearable health diagnostic devices, which will include various types of sensors and will be transmitted towards the corresponding Health Monitoring Centers. The permanent medical data of patients will be kept in the corresponding Home Data Bases, while the measured biomedical data will be sent to the Visitor Health Monitor Center and Visitor Data Base that serves the area of present location of the patient. By combining the measured biomedical data and the permanent medical data, Health Medical Centers will be able to coordinate the needed actions and help the local medical teams to make quickly the best decisions that could be crucial for the patient health, and that can reduce the cost of health service.

  14. Intelligent IPv6 based iot network monitoring and altering system on ...

    African Journals Online (AJOL)

    Intelligent IPv6 based iot network monitoring and altering system on Cooja framework. ... Journal of Fundamental and Applied Sciences. Journal Home · ABOUT THIS ... Keywords: IoT; Cooja framework; Contiki OS; packet monitoring.

  15. Network and Service Monitoring in Heterogeneous Home Networks

    NARCIS (Netherlands)

    Delphinanto, A.

    2012-01-01

    Home networks are becoming dynamic and technologically heterogeneous. They consist of an increasing number of devices which offer several functionalities and can be used for many different services. In the home, these devices are interconnected using a mixture of networking technologies (for

  16. A new venous infusion pathway monitoring system.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sata, Koji; Hamada, Shingo; Caldwell, W Morton

    2007-01-01

    A new infusion catheter pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer has been developed for hospital and home use. The sensor consists of coaxial three-layer conductive tapes wrapped around the polyvinyl chloride infusion tube. The inner tape is the main electrode, which records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. The outside tape layer is a reference electrode to monitor the AC voltage around the main electrode. The center tape layer is connected to system ground and functions as a shield. The microcomputer calculates the ratio of the induced AC voltages recorded by the main and reference electrodes and if the ratio indicates a detached infusion, alerts the nursing station, via the nurse call system or low transmitting power mobile phone.

  17. Integrated photovoltaic (PV) monitoring system

    Science.gov (United States)

    Mahinder Singh, Balbir Singh; Husain, NurSyahidah; Mohamed, Norani Muti

    2012-09-01

    The main aim of this research work is to design an accurate and reliable monitoring system to be integrated with solar electricity generating system. The performance monitoring system is required to ensure that the PVEGS is operating at an optimum level. The PV monitoring system is able to measure all the important parameters that determine an optimum performance. The measured values are recorded continuously, as the data acquisition system is connected to a computer, and data is stored at fixed intervals. The data can be locally used and can also be transmitted via internet. The data that appears directly on the local monitoring system is displayed via graphical user interface that was created by using Visual basic and Apache software was used for data transmission The accuracy and reliability of the developed monitoring system was tested against the data that captured simultaneously by using a standard power quality analyzer device. The high correlation which is 97% values indicates the level of accuracy of the monitoring system. The aim of leveraging on a system for continuous monitoring system is achieved, both locally, and can be viewed simultaneously at a remote system.

  18. Measurement-Based Evaluation of Installed Filtration System Performance in Single-Family Homes

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu Rengie; Singer, Brett C.

    2014-04-03

    This guide discusses important study design issues to consider when conducting an on-site evaluation of filtration system performance. The two most important dichotomies to consider in developing a study protocol are (1) whether systems are being evaluated in occupied or unoccupied homes and (2) whether different systems are being compared in the same homes or if the comparison is between systems installed in different homes. This document provides perspective and recommendations about a suite of implementation issues including the choice of particle measurement devices, selection of sampling locations, ways to control and/or monitor factors and processes that can impact particle concentrations, and data analysis approaches.

  19. Arduino Based Infant Monitoring System

    Science.gov (United States)

    Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi

    2017-08-01

    This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.

  20. A Review of Systems and Technologies for Smart Homes and Smart Grids

    Directory of Open Access Journals (Sweden)

    Gabriele Lobaccaro

    2016-05-01

    Full Text Available In the actual era of smart homes and smart grids, advanced technological systems that allow the automation of domestic tasks are developing rapidly. There are numerous technologies and applications that can be installed in smart homes today. They enable communication between home appliances and users, and enhance home appliances’ automation, monitoring and remote control capabilities. This review article, by introducing the concept of the smart home and the advent of the smart grid, investigates technologies for smart homes. The technical descriptions of the systems are presented and point out advantages and disadvantages of each technology and product today available on the market. Barriers, challenges, benefits and future trends regarding the technologies and the role of users have also been discussed.

  1. Single-Camera-Based Method for Step Length Symmetry Measurement in Unconstrained Elderly Home Monitoring.

    Science.gov (United States)

    Cai, Xi; Han, Guang; Song, Xin; Wang, Jinkuan

    2017-11-01

    single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring. To build unconstrained monitoring environments, we propose a method to measure step length symmetry ratio (a useful gait parameter representing gait symmetry without significant relationship with age) from unconstrained straight walking using a single camera, without strict restrictions on walking directions or routes. according to projective geometry theory, we first develop a calculation formula of step length ratio for the case of unconstrained straight-line walking. Then, to adapt to general cases, we propose to modify noncollinear footprints, and accordingly provide general procedure for step length ratio extraction from unconstrained straight walking. Our method achieves a mean absolute percentage error (MAPE) of 1.9547% for 15 subjects' normal and abnormal side-view gaits, and also obtains satisfactory MAPEs for non-side-view gaits (2.4026% for 45°-view gaits and 3.9721% for 30°-view gaits). The performance is much better than a well-established monocular gait measurement system suitable only for side-view gaits with a MAPE of 3.5538%. Independently of walking directions, our method can accurately estimate step length ratios from unconstrained straight walking. This demonstrates our method is applicable for elders' daily gait monitoring to provide valuable information for elderly health care, such as abnormal gait recognition, fall risk assessment, etc. single-camera-based gait monitoring is unobtrusive, inexpensive, and easy-to-use to monitor daily gait of seniors in their homes. However, most studies require subjects to walk perpendicularly to camera's optical axis or along some specified routes, which limits its application in elderly home monitoring

  2. Maintenance of radiation monitoring systems

    International Nuclear Information System (INIS)

    Aoyama, Kei

    2001-01-01

    As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)

  3. Gas House Autonomous System Monitoring

    Science.gov (United States)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  4. Beyond Self-Monitoring: Understanding Non-functional Aspects of Home-based Healthcare Technology

    DEFF Research Database (Denmark)

    Grönvall, Erik; Verdezoto, Nervo

    2013-01-01

    the appropriation of healthcare technologies and people with comorbidity may have diverse but co-existing monitoring needs. In this paper, we seek to understand home-based health monitoring practices to better design and integrate them into people’s everyday life. We perform an analysis of socio......-technical complexities in home-based healthcare technologies through three case studies of self-monitoring: 1) pre-eclampsia (i.e. pregnancy poisoning), 2) heart conditions, and 3) preventive care. Through the analysis seven themes emerged (people, resources, places, routines, knowledge, control and motivation) that can...... facilitate the understanding of home-based healthcare activities. We present three modes of self-monitoring use and provide a set of design recommendations for future Ubicomp designs of home-based healthcare technology....

  5. DOE Zero Energy Ready Home Case Study, Weiss Building & Development, LLC., System Home, River Forest, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-09-01

    The Passive House Challenge Home located in River Forest, Illinois, is a 5-bedroom, 4.5-bath, 3,600 ft2 two-story home (plus basement) that costs about $237 less per month to operate than a similar sized home built to the 2009 IECC. For a home with no solar photovoltaic panels installed, it scored an amazingly low 27 on the Home Energy Rating System (HERS) score.An ENERGY STAR-rated dishwasher, clothes washer, and refrigerator; an induction cooktop, condensing clothes dryer, and LED lighting are among the energy-saving devices inside the home. All plumbing fixtures comply with EPA WaterSense criteria. The home was awarded a 2013 Housing Innovation Award in the "systems builder" category.

  6. Unattended Monitoring System Design Methodology

    International Nuclear Information System (INIS)

    Drayer, D.D.; DeLand, S.M.; Harmon, C.D.; Matter, J.C.; Martinez, R.L.; Smith, J.D.

    1999-01-01

    A methodology for designing Unattended Monitoring Systems starting at a systems level has been developed at Sandia National Laboratories. This proven methodology provides a template that describes the process for selecting and applying appropriate technologies to meet unattended system requirements, as well as providing a framework for development of both training courses and workshops associated with unattended monitoring. The design and implementation of unattended monitoring systems is generally intended to respond to some form of policy based requirements resulting from international agreements or domestic regulations. Once the monitoring requirements are established, a review of the associated process and its related facilities enables identification of strategic monitoring locations and development of a conceptual system design. The detailed design effort results in the definition of detection components as well as the supporting communications network and data management scheme. The data analyses then enables a coherent display of the knowledge generated during the monitoring effort. The resultant knowledge is then compared to the original system objectives to ensure that the design adequately addresses the fundamental principles stated in the policy agreements. Implementation of this design methodology will ensure that comprehensive unattended monitoring system designs provide appropriate answers to those critical questions imposed by specific agreements or regulations. This paper describes the main features of the methodology and discusses how it can be applied in real world situations

  7. Neutron monitoring system

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Arita, Setsuo.

    1994-01-01

    The present invention concerns neutron monitoring for monitoring reactor power, and presents a generation state of abnormal signals by monitoring output signals from neutron sensors, judges abnormal signals at an excessively high level outputted from the sensors to a measuring operator or a reactor operator. That is, a threshold value judging means judges whether a sensor signal exceeds a predetermined threshold value or not. When it exceeds the value, recognition signals are outputted to a memory means. The memory means memorizes the times of input of the recognition signals on every period of interval signals outputted from a reference signal generation means. The memory content of the memory means and the previously inputted hysteresis of the sensor are compared and judged, to determine the extent of the degradation of the sensors and output the result of the judgement and hysteresis information to the display means. The input means accesses to the judging means and the memory means to retrieve and correct the content of the memory means and the hysteresis information inputted to the judging means. (I.S.)

  8. Radiation monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  9. Radiation monitoring system

    International Nuclear Information System (INIS)

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino

    2015-01-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  10. DOMOTICS Aplicability and home automation systems

    Directory of Open Access Journals (Sweden)

    César Luiz de Azevedo Dias

    2010-05-01

    Full Text Available This article discusses the benefits and applicability of domestic automation, also known as Domotics. According to Domotics Integration Project (DIP, Domotics or smart house technology is the integration of services and technologies applied to homes, flats, apartments, houses and small buildings with the purpose of automating them and obtaining and increasing safety and security, comfort, communication and technical management. This papper also presents a summary of the elements which may be part of a “smart home”, the advantages given by its integration and, illustrations of various systems and technologies applied to domestic automation that have achieved both national and international commercial relevance.

  11. Savannah River Plant remote environmental monitoring system

    International Nuclear Information System (INIS)

    Schubert, J.F.

    1987-01-01

    The SRP remote environmental monitoring system consists of separations facilities stack monitors, production reactor stack monitors, twelve site perimeter monitors, river and stream monitors, a geostationary operational environmental satellite (GOES) data link, reactor cooling lake thermal monitors, meteorological tower system, Weather Information and Display (WIND) system computer, and the VANTAGE data base management system. The remote environmental monitoring system when fully implemented will provide automatic monitoring of key stack releases and automatic inclusion of these source terms in the emergency response codes

  12. ERMS - Environmental Radiation Monitoring System

    International Nuclear Information System (INIS)

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  13. An intelligent fetal monitoring system

    International Nuclear Information System (INIS)

    Inaba, J.; Akatsuka, T.; Kubo, T.; Iwasaki, H.

    1986-01-01

    An intelligent monitoring system is constructed by a multi-micro-computer system. The monitoring signals are fetal heart rate (FHR) and uterine contraction (UC) through the conventional monitoring device for a day until the delivery. These signals are fed to a micro-computer in digital format, and evaluated by the computer in real time according to the diagnostic algorithm of the expert physician. Monitoring signals are always displayed on the CRT screen and in the case of dangerous state of the fetus, warning signal will appear on the screen and the doctor or nurse will be called. All these signals are sent to the next micro-computer with 10MB hard disk system. On this computer, the doctor and nurse can retrieve and inspect the details of the process by clock-key and/or events-key. After finishing monitoring process, summarized report is constructed and printed out on the paper

  14. A fully automated health-care monitoring at home without attachment of any biological sensors and its clinical evaluation.

    Science.gov (United States)

    Motoi, Kosuke; Ogawa, Mitsuhiro; Ueno, Hiroshi; Kuwae, Yutaka; Ikarashi, Akira; Yuji, Tadahiko; Higashi, Yuji; Tanaka, Shinobu; Fujimoto, Toshiro; Asanoi, Hidetsugu; Yamakoshi, Ken-ichi

    2009-01-01

    Daily monitoring of health condition is important for an effective scheme for early diagnosis, treatment and prevention of lifestyle-related diseases such as adiposis, diabetes, cardiovascular diseases and other diseases. Commercially available devices for health care monitoring at home are cumbersome in terms of self-attachment of biological sensors and self-operation of the devices. From this viewpoint, we have been developing a non-conscious physiological monitor installed in a bath, a lavatory, and a bed for home health care and evaluated its measurement accuracy by simultaneous recordings of a biological sensors directly attached to the body surface. In order to investigate its applicability to health condition monitoring, we have further developed a new monitoring system which can automatically monitor and store the health condition data. In this study, by evaluation on 3 patients with cardiac infarct or sleep apnea syndrome, patients' health condition such as body and excretion weight in the toilet and apnea and hypopnea during sleeping were successfully monitored, indicating that the system appears useful for monitoring the health condition during daily living.

  15. The CUORE slow monitoring systems

    Science.gov (United States)

    Gladstone, L.; Biare, D.; Cappelli, L.; Cushman, J. S.; Del Corso, F.; Fujikawa, B. K.; Hickerson, K. P.; Moggi, N.; Pagliarone, C. E.; Schmidt, B.; Wagaarachchi, S. L.; Welliver, B.; Winslow, L. A.

    2017-09-01

    CUORE is a cryogenic experiment searching primarily for neutrinoless double decay in 130Te. It will begin data-taking operations in 2016. To monitor the cryostat and detector during commissioning and data taking, we have designed and developed Slow Monitoring systems. In addition to real-time systems using LabVIEW, we have an alarm, analysis, and archiving website that uses MongoDB, AngularJS, and Bootstrap software. These modern, state of the art software packages make the monitoring system transparent, easily maintainable, and accessible on many platforms including mobile devices.

  16. Medicare and Medicaid Programs; CY 2017 Home Health Prospective Payment System Rate Update; Home Health Value-Based Purchasing Model; and Home Health Quality Reporting Requirements. Final rule.

    Science.gov (United States)

    2016-11-03

    This final rule updates the Home Health Prospective Payment System (HH PPS) payment rates, including the national, standardized 60-day episode payment rates, the national per-visit rates, and the non-routine medical supply (NRS) conversion factor; effective for home health episodes of care ending on or after January 1, 2017. This rule also: Implements the last year of the 4-year phase-in of the rebasing adjustments to the HH PPS payment rates; updates the HH PPS case-mix weights using the most current, complete data available at the time of rulemaking; implements the 2nd-year of a 3-year phase-in of a reduction to the national, standardized 60-day episode payment to account for estimated case-mix growth unrelated to increases in patient acuity (that is, nominal case-mix growth) between CY 2012 and CY 2014; finalizes changes to the methodology used to calculate payments made under the HH PPS for high-cost "outlier" episodes of care; implements changes in payment for furnishing Negative Pressure Wound Therapy (NPWT) using a disposable device for patients under a home health plan of care; discusses our efforts to monitor the potential impacts of the rebasing adjustments; includes an update on subsequent research and analysis as a result of the findings from the home health study; and finalizes changes to the Home Health Value-Based Purchasing (HHVBP) Model, which was implemented on January 1, 2016; and updates to the Home Health Quality Reporting Program (HH QRP).

  17. An Ontology-based Context-aware System for Smart Homes: E-care@home

    Directory of Open Access Journals (Sweden)

    Marjan Alirezaie

    2017-07-01

    Full Text Available Smart home environments have a significant potential to provide for long-term monitoring of users with special needs in order to promote the possibility to age at home. Such environments are typically equipped with a number of heterogeneous sensors that monitor both health and environmental parameters. This paper presents a framework called E-care@home, consisting of an IoT infrastructure, which provides information with an unambiguous, shared meaning across IoT devices, end-users, relatives, health and care professionals and organizations. We focus on integrating measurements gathered from heterogeneous sources by using ontologies in order to enable semantic interpretation of events and context awareness. Activities are deduced using an incremental answer set solver for stream reasoning. The paper demonstrates the proposed framework using an instantiation of a smart environment that is able to perform context recognition based on the activities and the events occurring in the home.

  18. An Ontology-based Context-aware System for Smart Homes: E-care@home.

    Science.gov (United States)

    Alirezaie, Marjan; Renoux, Jennifer; Köckemann, Uwe; Kristoffersson, Annica; Karlsson, Lars; Blomqvist, Eva; Tsiftes, Nicolas; Voigt, Thiemo; Loutfi, Amy

    2017-07-06

    Smart home environments have a significant potential to provide for long-term monitoring of users with special needs in order to promote the possibility to age at home. Such environments are typically equipped with a number of heterogeneous sensors that monitor both health and environmental parameters. This paper presents a framework called E-care@home, consisting of an IoT infrastructure, which provides information with an unambiguous, shared meaning across IoT devices, end-users, relatives, health and care professionals and organizations. We focus on integrating measurements gathered from heterogeneous sources by using ontologies in order to enable semantic interpretation of events and context awareness. Activities are deduced using an incremental answer set solver for stream reasoning. The paper demonstrates the proposed framework using an instantiation of a smart environment that is able to perform context recognition based on the activities and the events occurring in the home.

  19. Examining Korean and Korean American older adults' perceived acceptability of home-based monitoring technologies in the context of culture.

    Science.gov (United States)

    Chung, Jane; Thompson, Hilaire J; Joe, Jonathan; Hall, Amanda; Demiris, George

    2017-01-01

    Despite the increasing use of home-based monitoring technologies by older adults, few studies have examined older adults' acceptance of these technologies, especially among people from diverse cultural groups. The purpose of this study was to explore Korean and Korean American older adults' attitudes toward and perceptions of home-based monitoring technologies in a cultural context. A qualitative analysis of focus groups and individual interviews using inductive coding methods and a constant comparative approach for emerging themes was conducted. Several cultural factors that determine the acceptability of home-based monitoring technologies were identified. Most notably, the necessity of living alone due to loosened filial tradition and immigration was a main motivator for adopting these technologies for both Korean and Korean Americans. The level of satisfaction with the health care system or therapeutic interaction affected participants' perceived need for technologies. Compared with the Korean American group, Korean older adults regarded the government's role as more important in increasing adoption and use of new technologies. Contextual factors need to be considered when explaining perceptions of home-based monitoring technologies among older adults from various ethnic groups and developing diffusion strategies according to end users' attitudes, experiences, and cultural backgrounds.

  20. DC Home Appliances for DC Distribution System

    Directory of Open Access Journals (Sweden)

    MUHAMMAD KAMRAN

    2017-10-01

    Full Text Available This paper strengthens the idea of DC distribution system for DC microgrid consisting of a building of 50 apartments. Since the war of currents AC system has been dominant because of the paucity of research in the protection of the DC system. Now with the advance research in power electronics material and components, generation of electricity is inherently DC as by solar PV, fuel cell and thermoelectric generator that eliminates the rectification process. Transformers are replaced by the power electronics buck-boost converters. DC circuit breakers have solved the protection problems for both DC transmission and distribution system. In this paper 308V DC microgrid is proposed and home appliances (DC internal are modified to operate on 48V DC from DC distribution line. Instead of using universal and induction motors in rotary appliances, BLDC (Brushless DC motors are proposed that are highly efficient with minimum electro-mechanical and no commutation losses. Proposed DC system reduces the power conversion stages, hence diminishes the associated power losses and standby losses that boost the overall system efficiency. So in view of all this a conventional AC system can be replaced by a DC system that has many advantages by cost as well as by performance

  1. Wood frame systems for wood homes

    Directory of Open Access Journals (Sweden)

    Julio Cesar Molina

    2010-12-01

    Full Text Available The use of constructive systems that combine strength, speed, with competitive differential techniques and mainly, compromising with the environment, is becoming more popular in Brazil. The constructive system in wood frame for houses of up to five stories is very interesting, because it is a light system, structured in reforested treated wood which allows the combination of several materials, besides allowing speed in the construction and total control of the expenses already in the project phase for being industrialized. The structural behavior of the wood frame is superior to the structural masonry in strength, thermal and acoustic comfort. However, in Brazil, the wood frame is still little known and used, due to lack of technical knowledge about the system, prejudice associated the bad use of the wood as construction material, or still, in some cases, lack of normalization. The aim of this manuscript consists of presenting the main technical characteristics and advantages of the constructive system in wood frame homes, approaching the main stages of the constructive process through examples, showing the materials used in the construction, in addition the main international normative recommendations of the project. Thus, this manuscript also hopes to contribute to the popularization of the wood frame system in Brazil, since it is a competitive, fast and ecologically correct system. Moreover, nowadays, an enormous effort of the technical, commercial and industrial section has been accomplished for the development of this system in the country.

  2. A blade deflection monitoring system

    DEFF Research Database (Denmark)

    2017-01-01

    A wind turbine blade comprising a system for monitoring the deflection of a wind turbine blade is described. The system comprises a wireless range-measurement system, having at least one wireless communication device located towards the root end of the blade and at least one wireless communication...

  3. Environment Adaptive Lighting Systems for Smart Homes

    Directory of Open Access Journals (Sweden)

    Cem Mehmet Catalbas

    2017-09-01

    Full Text Available In this work, an application of adaptive lighting system is proposed for smart homes. In this paper, it is suggested that, an intelligent lighting system with outdoor adaptation can be realized via a real fisheye image. During the implementation of the proposed method, the fuzzy c-means method, which is a commonly used data clustering method, has been used. The input image is divided into three different regions according to its brightness levels. Then, the RGB image is converted to CIE 1931 XYZ color space; and the obtained XYZ values are converted to x and y values. The parameters of x and y values are shown in CIE Chromaticity Diagram for different regions in the sky. Thereafter, the coordinate values are converted to Correlated Color Temperature by using two different formulas. Additionally, the conversion results are examined with respect to actual and estimated CCT values.

  4. Modular Biometric Monitoring System

    Science.gov (United States)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor)

    2017-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to control communication of data, via the bus, with each of the plurality of data acquisition modules.

  5. The JOYO remote monitoring system

    International Nuclear Information System (INIS)

    Damico, Joseph P.; Hashimoto, Yu

    2000-01-01

    The evolution of the personal computer, operating systems and applications software and the Internet has brought drastic change and many benefits worldwide. Remote monitoring systems benefit from computer network and other modern software technologies. The availability of fast, inexpensive and secure communications enables new solutions for monitoring system applications. The JOYO Remote Monitoring System (RMS) utilizes computer network communications and modular software design to provide a distributed integrated solution for monitoring multiple storage locations. This paper describes the remote monitoring system installed at the JOYO Fast Reactor. The system combines sensors, software, and computer network technologies to create a powerful data collection, storage and dissemination capability. The RMS provides a flexible, scalable solution for a variety of applications. The RMS integrates a variety of state of the art technologies from several sources and serves as a test bed for cutting edge technologies that can be shared with outside users. This paper describes the system components and their operation and discusses system benefits. Current activities and future plants for the JOYO RMS will be discussed. (author)

  6. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  7. How Parents of Teens Store and Monitor Prescription Drugs in the Home

    Science.gov (United States)

    Friese, Bettina; Moore, Roland S.; Grube, Joel W.; Jennings, Vanessa K.

    2013-01-01

    Qualitative interviews were conducted with parents of teens to explore how parents store and monitor prescription drugs in the home. Most parents had prescription drugs in the house, but took few precautions against teens accessing these drugs. Strategies for monitoring included moving the drugs to different locations, remembering how many pills…

  8. ELECTRONIC FILE MONITORING SYSTEM

    African Journals Online (AJOL)

    GBUBEMI

    2014-11-06

    Nov 6, 2014 ... The result of the developed system shows a simple and effective graphic user interface ... business transactions, decision-making records and storage of .... Start. Input username and password. Access denied was login.

  9. A Grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin [Fermi National Accelerator Laboratory (United States); Nowack, Andreas [RWTH Aachen (Germany); Padhi, Sanjay [University of California San Diego (United States); Sarkar, Subir, E-mail: subir.sarkar@cern.c [INFN, Sezione di Pisa and Scuola Normale Superiore, Pisa (Italy)

    2010-04-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components : (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  10. A grid job monitoring system

    International Nuclear Information System (INIS)

    Dumitrescu, Catalin; Nowack, Andreas; Padhi, Sanjay; Sarkar, Subir

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  11. On predicting monitoring system effectiveness

    Science.gov (United States)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  12. Home e-health system integration in the Smart Home through a common media server.

    Science.gov (United States)

    Pau, I; Seoane, F; Lindecrantz, K; Valero, M A; Carracedo, J

    2009-01-01

    Home e-health systems and services are revealed as one of the most important challenges to promote Quality of Life related to Health in the Information Society. Leading companies have worked on e-health systems although the majority of them are addressed to hospital or primary care settings. The solution detailed in this paper offers a personal health system to be integrated with Smart Home services platform to support home based e-care. Thus, the home e-health system and architecture detailed in this research work is ready to supply a seamless personal care solution both from the biomedical data analysis, service provision, security guarantee and information management s point of view. The solution is ready to be integrated within the Accessible Digital Home, a living lab managed by Universidad Politécnica de Madrid for R&D activities.

  13. UAV Delivery Monitoring System

    Directory of Open Access Journals (Sweden)

    San Khin Thida

    2018-01-01

    Full Text Available UAV-based delivery systems are increasingly being used in the logistics field, particularly to achieve faster last-mile delivery. This study develops a UAV delivery system that manages delivery order assignments, autonomous flight operation, real time control for UAV flights, and delivery status tracking. To manage the delivery item assignments, we apply the concurrent scheduler approach with a genetic algorithm. The present paper describes real time flight data based on a micro air vehicle communication protocol (MAVLink. It also presents the detailed hardware components used for the field tests. Finally, we provide UAV component analysis to choose the suitable components for delivery in terms of battery capacity, flight time, payload weight and motor thrust ratio.

  14. COMMUNITY BASED HOME ENERGY MANAGEMENT SYSTEM

    Directory of Open Access Journals (Sweden)

    Muhammad Adnan Aziz

    2017-05-01

    Full Text Available In a Smart Grid (SG scenario, domestic consumers can gain cost reduction benefit by scheduling their Appliance Activation Time (AAT towards the slots of low charge. Minimization in cost is essential in Home Energy Management Systems (HEMS to induce consumers acceptance for power scheduling to accommodate for a Demand Response (DR at peak hours. Despite the fact that many algorithms address the power scheduling for HEMS, community based optimization has not been the focus. This paper presents an algorithm that targets the minimization of energy costs of whole community while keeping a low Peak to Average Ratio (PAR and smooth Power Usage Pattern (PUP. Objective of cost reduction is accomplished by finding most favorable AAT by Particle Swarm Optimization (PSO in conjunction with Inclined Block Rate (IBR approach and Circular Price Shift (CPS. Simulated numerical results demonstrate the effectiveness of CPS to assist the merger of PSO & IBR to enhance the reduction/stability of PAR and cost reduction.

  15. Strapdown Homing Guidance System Design for Some Ammunition

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The strapdown homing guidance system for some ammunition was mainly studied. A strong tracking Kalman filter was designed for the strapdown homing guidance system using the information measured by the strapdown homing seeker to estimate relative movement variables between the ammunition and target. Then the optimal proportional law, which using the estimated information, guided the ammunition. Simulation results show that the designed strapdown homing guidance system with strong tracking Kalman filter can attack the maneuvering target effectively, and satisfy the performance index for the guided ammunition system.

  16. Development of a Health Care Information System for the Elderly at Home

    Directory of Open Access Journals (Sweden)

    Wang Dong

    2016-01-01

    Full Text Available The growing population aging is a serious social problem in the world today. Accidental death at home is increasing because abnormal conditions can not be discovered in time, especially to the elderly who live alone. Besides, according to statistics, over 80 percent of the elderly need the service of home care in China. A health care information system for the elderly at home is developed to monitor the real–time state of the elderly remotely in this thesis. The system can show the current positions of the elderly in the house and judge whether they are in dangerous locations or have dangerous activities. In the case of emergency, the elderly can press the emergency button. The system also provides some help for the elderly’s daily life. The system offers the advantage for living at home more safely and more comfortably, and has better application prospect

  17. Smart Homes with Voice Activated Systems for Disabled People

    OpenAIRE

    Bekir Busatlic; Nejdet Dogru; Isaac Lera; Enes Sukic

    2017-01-01

    Smart home refers to the application of various technologies to semi-unsupervised home control It refers to systems that control temperature, lighting, door locks, windows and many other appliances. The aim of this study was to design a system that will use existing technology to showcase how it can benefit people with disabilities. This work uses only off-the-shelf products (smart home devices and controllers), speech recognition technology, open-source code libraries. The Voice Activated Sm...

  18. Personnel external dose monitoring system

    International Nuclear Information System (INIS)

    Zhao Hengyuan

    1989-01-01

    The status and trend of personnel external dose monitoring system are introduced briefly. Their characteristics, functions and TLD bedges of some commercially available automatic TLD system, including UD-710A (Matsushita, Japan), Harshaw-2271, 2276 (Harshaw, USA), Harshaw-8000 (Harshaw/Filtrol), Studsvik-1313 (Sweden) and Pitman-800 (UK) were depicted in detail. Finally, personnel dose management and record keeping system were presented and two examples were given

  19. Privacy versus autonomy: a tradeoff model for smart home monitoring technologies.

    Science.gov (United States)

    Townsend, Daphne; Knoefel, Frank; Goubran, Rafik

    2011-01-01

    Smart homes are proposed as a new location for the delivery of healthcare services. They provide healthcare monitoring and communication services, by using integrated sensor network technologies. We validate a hypothesis regarding older adults' adoption of home monitoring technologies by conducting a literature review of articles studying older adults' attitudes and perceptions of sensor technologies. Using current literature to support the hypothesis, this paper applies the tradeoff model to decisions about sensor acceptance. Older adults are willing to trade privacy (by accepting a monitoring technology), for autonomy. As the information captured by the sensor becomes more intrusive and the infringement on privacy increases, sensors are accepted if the loss in privacy is traded for autonomy. Even video cameras, the most intrusive sensor type were accepted in exchange for the height of autonomy which is to remain in the home.

  20. GTA Beamloss-Monitor System

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamless-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamless-Monitor System measures the induced gamma radiation, from (p, γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamless-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/1993 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper

  1. GTA beamloss-monitor system

    International Nuclear Information System (INIS)

    Rose, C.R.; Fortgang, C.M.; Power, J.P.

    1992-01-01

    The GTA Beamloss-Monitor System at Los Alamos National Laboratory has been designed to detect high-energy particle loss in the accelerator beamline and shut down the accelerator before any damage can occur. To do this, the Beamloss-Monitor System measures the induced gamma radiation, from (p,γ) reactions, at 15 selected points along the beamline, converts this measured radiation to electrical signals, integrates and compares them to preset limits, and, in the event of an over-limit condition causes the Fast-Protect System to shut down the entire accelerator. The system dynamic range exceeds 70 dB which will enable experimenters to use the Beamloss-Monitor System to help steer the beam as well as provide signals for a Fast-Protect System. The system response time is less than 7 μs assuming a step-function, worst-case beam spill of 50 mA. The system resolution, based on the noise floor of the electronics, is about 1.3 mRads/s. Production units have been built and meet the above specifications. The remainder of the system will be installed and tested later in 1992/93 with the GTA accelerator. The ionization chamber sensitivity and response time are described in the paper. (Author) 4 figs., ref

  2. A clinician-driven home care delivery system.

    Science.gov (United States)

    August, D A; Faubion, W C; Ryan, M L; Haggerty, R H; Wesley, J R

    1993-12-01

    The financial, entrepreneurial, administrative, and legal forces acting within the home care arena make it difficult for clinicians to develop and operate home care initiatives within an academic setting. HomeMed is a clinician-initiated and -directed home care delivery system wholly owned by the University of Michigan. The advantages of a clinician-directed system include: Assurance that clinical and patient-based factors are the primary determinants of strategic and procedural decisions; Responsiveness of the system to clinician needs; Maintenance of an important role for the referring physician in home care; Economical clinical research by facilitation of protocol therapy in ambulatory and home settings; Reduction of lengths of hospital stays through clinician initiatives; Incorporation of outcome analysis and other research programs into the mission of the system; Clinician commitment to success of the system; and Clinician input on revenue use. Potential disadvantages of a clinician-based system include: Entrepreneurial, financial, and legal naivete; Disconnection from institutional administrative and data management resources; and Inadequate clinician interest and commitment. The University of Michigan HomeMed experience demonstrates a model of clinician-initiated and -directed home care delivery that has been innovative, profitable, and clinically excellent, has engendered broad physician, nurse, pharmacist, and social worker enthusiasm, and has supported individual investigator clinical protocols as well as broad outcomes research initiatives. It is concluded that a clinician-initiated and -directed home care program is feasible and effective, and in some settings may be optimal.

  3. Drinking-water monitoring systems

    International Nuclear Information System (INIS)

    1994-01-01

    A new measuring system was developed by the Austrian Research Centre Seibersdorf for monitoring the quality of drinking-water. It is based on the experience made with the installation of UWEDAT (registered trademark) environmental monitoring networks in several Austrian provinces and regions. The standard version of the drinking-water monitoring system comprises sensors for measuring chemical parameters in water, radioactivity in water and air, and meteorological values of the environment. Further measuring gauges, e.g. for air pollutants, can be connected at any time, according to customers' requirements. For integration into regional and supraregional networks, station computers take over the following tasks: Collection of data and status signals transmitted by the subsystem, object protection, intermediate storage and communication of data to the host or several subcentres via Datex-P postal service, permanent lines or radiotransmission

  4. Remote Arrhythmia Monitoring System Developed

    Science.gov (United States)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  5. A Telehealth System for Remote Auditory Evoked Potential Monitoring

    OpenAIRE

    Millan, Jorge; Yunda, Leonardo

    2013-01-01

    A portable, Internet-based EEG/Auditory Evoked Potential (AEP) monitoring system was developed for remote electrophysiological studies during sleep. The system records EEG/AEP simultaneously at the subject?s home for increased comfort and flexibility. The system provides simultaneous recording and remote viewing of EEG, EMG and EOG waves and allows on-line averaging of auditory evoked potentials. The design allows the recording of all major AEP components (brainstem, middle and late latency E...

  6. Thermoluminescence dosimetry environmental monitoring system

    International Nuclear Information System (INIS)

    Bortoluzzi, S.

    1989-01-01

    In this report, characteristics and performances of an environmental monitoring system with thermoluminescence dosimetry are presented. Most of the work deals with the main physical parameters necessary for measurements of ambiental dose. At the end of this report some of level doses in the environment around the site of the ENEA Center of Energy Research Salluggia (Italy) are illustrated

  7. Adding navigation, artificial audition and vital sign monitoring capabilities to a telepresence mobile robot for remote home care applications.

    Science.gov (United States)

    Laniel, Sebastien; Letourneau, Dominic; Labbe, Mathieu; Grondin, Francois; Polgar, Janice; Michaud, Francois

    2017-07-01

    A telepresence mobile robot is a remote-controlled, wheeled device with wireless internet connectivity for bidirectional audio, video and data transmission. In health care, a telepresence robot could be used to have a clinician or a caregiver assist seniors in their homes without having to travel to these locations. Many mobile telepresence robotic platforms have recently been introduced on the market, bringing mobility to telecommunication and vital sign monitoring at reasonable costs. What is missing for making them effective remote telepresence systems for home care assistance are capabilities specifically needed to assist the remote operator in controlling the robot and perceiving the environment through the robot's sensors or, in other words, minimizing cognitive load and maximizing situation awareness. This paper describes our approach adding navigation, artificial audition and vital sign monitoring capabilities to a commercially available telepresence mobile robot. This requires the use of a robot control architecture to integrate the autonomous and teleoperation capabilities of the platform.

  8. Visualization System for Monitoring Data Management Systems

    Directory of Open Access Journals (Sweden)

    Emanuel Pinho

    2016-11-01

    Full Text Available Usually, a Big Data system has a monitoring system for performance evaluation and error prevention. There are some disadvantages in the way that these tools display the information and its targeted approach to physical components. The main goal is to study visual and interactive mechanisms that allow the representation of monitoring data in grid computing environments, providing the end-user information, which can contribute objectively to the system analysis. This paper is an extension of the paper presented at (Pinho and Carvalho 2016 and has the purpose to present the state of the art, carries out the proposed solution and present the achieved goals.

  9. Energy Monitoring System Berbasis Web

    Directory of Open Access Journals (Sweden)

    Novan Zulkarnain

    2013-12-01

    Full Text Available Government through the Ministry of Energy and Mineral Resources (ESDM encourages the energy savings at whole buildings in Indonesia. Energy Monitoring System (EMS is a web-based solution to monitor energy usage in a building. The research methods used are the analysis, prototype design and testing. EMSconsists of hardware which consists of electrical sensors, temperature-humidity sensor, and a computer. Data on EMS are designed using Modbus protocol, stored in MySQL database application, and displayed on charts through Dashboard on LED TV using PHP programming.

  10. A typewriting system operated by head movements, based on home-computer equipment

    NARCIS (Netherlands)

    Heuvelmans, A.M.F.; Mélotte, H.E.M.; Neve, J.J.

    1990-01-01

    For persons who cannot move their hands and legs we have designed a relatively inexpensive typewriting system which can be operated by movements of the head. The typewriter is made up of commercially available home computer equipment - i e, a computer including monitor and printer and a headset

  11. Data Equivalency of an Interactive Voice Response System for Home Assessment of Back Pain and Function

    Directory of Open Access Journals (Sweden)

    William S Shaw

    2007-01-01

    Full Text Available BACKGROUND: Interactive voice response (IVR systems that collect survey data using automated, push-button telephone responses may be useful to monitor patients’ pain and function at home; however, its equivalency to other data collection methods has not been studied.

  12. Cost-effectiveness of home telemedical cardiotocography compared with traditional outpatient monitoring.

    Science.gov (United States)

    Tõrõk, M; Kovács, F; Doszpod, J

    2000-01-01

    We compared the cost of passive sensor telemedical non-stress cardiotocography performed at home and the same test performed by traditional equipment in an outpatient clinic in the Budapest area. The costs were calculated using two years' registered budget data from the home monitoring service in Budapest and the outpatient clinic of the department of obstetrics and gynaecology at the Haynal Imre University of Health Sciences. The traditional test at the university outpatient clinic cost 3652 forint for the health-care and 1000 forint in additional expenses for the patient (travel and time off work). This means that the total cost for each test in the clinic was 4652 forint. The cost of home telemedical cardiotocography was 1500 forint per test, but each test took 2.1 times as long. For a more realistic comparison between the two methods, we adjusted the cost to take account of the extra length of time that home monitoring required. The adjusted cost for home care was 3150 forint, some 32% lower than in the clinic. Passive sensor telemedical non-stress cardiotocography at home was therefore less expensive than the same test performed in the traditional way in an outpatient clinic.

  13. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  14. The NASA Carbon Monitoring System

    Science.gov (United States)

    Hurtt, G. C.

    2015-12-01

    Greenhouse gas emission inventories, forest carbon sequestration programs (e.g., Reducing Emissions from Deforestation and Forest Degradation (REDD and REDD+), cap-and-trade systems, self-reporting programs, and their associated monitoring, reporting and verification (MRV) frameworks depend upon data that are accurate, systematic, practical, and transparent. A sustained, observationally-driven carbon monitoring system using remote sensing data has the potential to significantly improve the relevant carbon cycle information base for the U.S. and world. Initiated in 2010, NASA's Carbon Monitoring System (CMS) project is prototyping and conducting pilot studies to evaluate technological approaches and methodologies to meet carbon monitoring and reporting requirements for multiple users and over multiple scales of interest. NASA's approach emphasizes exploitation of the satellite remote sensing resources, computational capabilities, scientific knowledge, airborne science capabilities, and end-to-end system expertise that are major strengths of the NASA Earth Science program. Through user engagement activities, the NASA CMS project is taking specific actions to be responsive to the needs of stakeholders working to improve carbon MRV frameworks. The first phase of NASA CMS projects focused on developing products for U.S. biomass/carbon stocks and global carbon fluxes, and on scoping studies to identify stakeholders and explore other potential carbon products. The second phase built upon these initial efforts, with a large expansion in prototyping activities across a diversity of systems, scales, and regions, including research focused on prototype MRV systems and utilization of COTS technologies. Priorities for the future include: 1) utilizing future satellite sensors, 2) prototyping with commercial off-the-shelf technology, 3) expanding the range of prototyping activities, 4) rigorous evaluation, uncertainty quantification, and error characterization, 5) stakeholder

  15. Experience with solar home systems in developing countries. A review

    International Nuclear Information System (INIS)

    Nieuwenhout, F.D.J.; Van Dijk, A.L.; Lasschuit, P.E.; Van Roekel, G.M.; Van Dijk, V.A.P.; Hirsch, D.; Arriaza, H.; Hankins, M.; Sharma, B.D.; Wade, H.

    2002-01-01

    Solar Energy is widely perceived as a promising technology for electricity generation in remote locations in developing countries. It is estimated that 1.3 million solar home systems had been installed by early 2000. An estimated one-third of installed systems were backed by foreign donor support in government programmes and two-thirds supplied by commercial dealers. The estimated growth in the deployment of solar lanterns is less than for SHS. One out of every 100 households that gain access to electricity in developing countries uses solar power. In spite of these successes, doubts have arisen about the effectiveness and suitability of small PV systems for rural development. Many organisational, financial and technical problems appear to present difficulties. A literature survey has been conducted to make an inventory of experience with solar PV applications for households in developing countries. The main finding is that an adequate service infrastructure is required to make projects viable. Household choice in system sizes is often too restricted in donor-funded projects. Smaller systems sold for cash can be a good alternative to credit systems by offering to increased affordability. Gaps in existing knowledge have been identified, which could be overcome by field monitoring programmes. 77 refs

  16. Home

    Science.gov (United States)

    Military Commission Seal VWAP Login Home Go ABOUT US Organization Overview Organizational Chart Families VWAP Login CCTV Sites Travel Media MC News CCTV Sites Travel Today at OMC Home Today at OMC Daily

  17. Development of home power management system | Apeh | Nigerian ...

    African Journals Online (AJOL)

    Development of home power management system. ... The unit also exhibited good implementation of the timing algorithm for all programmed outputs. It switched "ON" ... This flexibility in an automation system is one strong point of this device.

  18. Human Activity Recognition from Smart-Phone Sensor Data using a Multi-Class Ensemble Learning in Home Monitoring.

    Science.gov (United States)

    Ghose, Soumya; Mitra, Jhimli; Karunanithi, Mohan; Dowling, Jason

    2015-01-01

    Home monitoring of chronically ill or elderly patient can reduce frequent hospitalisations and hence provide improved quality of care at a reduced cost to the community, therefore reducing the burden on the healthcare system. Activity recognition of such patients is of high importance in such a design. In this work, a system for automatic human physical activity recognition from smart-phone inertial sensors data is proposed. An ensemble of decision trees framework is adopted to train and predict the multi-class human activity system. A comparison of our proposed method with a multi-class traditional support vector machine shows significant improvement in activity recognition accuracies.

  19. On Developing a Novel Versatile Framework for Heterogeneous Home Monitoring WSN networks

    Directory of Open Access Journals (Sweden)

    Ch. P. Antonopoulos

    2015-05-01

    Full Text Available The ability to deploy efficient and versatile WSN networks in the home environment is and will remain in the years to come a cornerstone objective in wireless networking. Respective services are continuously expanding requiring novel design and implementation approaches able to cover all relative present and even more importantly future requirements. This paper aims to present and convey knowledge and experience gained from such an effort in the context of home monitoring. Respective discussion covers all relative aspects and analyzes all critical challenges addressed ranging from identification and specification of the main requirements, to possible implementation approaches considered and finally the actual development undertaken. The final outcome considering the WSN home monitoring infrastructure as well as extracted knowledge and practical conclusions can be proven useful for further extending such an endeavour or even pursuing a different approach.

  20. Corral Monitoring System assessment results

    International Nuclear Information System (INIS)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system

  1. Corral Monitoring System assessment results

    Energy Technology Data Exchange (ETDEWEB)

    Filby, E.E.; Haskel, K.J.

    1998-03-01

    This report describes the results of a functional and operational assessment of the Corral Monitoring Systems (CMS), which was designed to detect and document accountable items entering or leaving a monitored site. Its development was motivated by the possibility that multiple sites in the nuclear weapons states of the former Soviet Union might be opened to such monitoring under the provisions of the Strategic Arms Reduction Treaty. The assessment was performed at three levels. One level evaluated how well the planned approach addressed the target application, and which involved tracking sensitive items moving into and around a site being monitored as part of an international treaty or other agreement. The second level examined the overall design and development approach, while the third focused on individual subsystems within the total package. Unfortunately, the system was delivered as disassembled parts and pieces, with very poor documentation. Thus, the assessment was based on fragmentary operating data coupled with an analysis of what documents were provided with the system. The system design seemed to be a reasonable match to the requirements of the target application; however, important questions about site manning and top level administrative control were left unanswered. Four weaknesses in the overall design and development approach were detected: (1) poor configuration control and management, (2) inadequate adherence to a well defined architectural standard, (3) no apparent provision for improving top level error tolerance, and (4) weaknesses in the object oriented programming approach. The individual subsystems were found to offer few features or capabilities that were new or unique, even at the conceptual level. The CMS might possibly have offered a unique combination of features, but this level of integration was never realized, and it had no unique capabilities that could be readily extracted for use in another system.

  2. Context Aware Systems, Methods and Trends in Smart Home Technology

    Science.gov (United States)

    Robles, Rosslin John; Kim, Tai-Hoon

    Context aware applications respond and adapt to changes in the computing environment. It is the concept of leveraging information about the end user to improve the quality of the interaction. New technologies in context-enriched services will use location, presence, social attributes, and other environmental information to anticipate an end user's immediate needs, offering more-sophisticated, situation-aware and usable functions. Smart homes connect all the devices and appliances in your home so they can communicate with each other and with you. Context-awareness can be applied to Smart Home technology. In this paper, we discuss the context-aware tools for development of Smart Home Systems.

  3. Liability aspects of home energy-rating systems

    Energy Technology Data Exchange (ETDEWEB)

    Hendrickson, P.L.

    1983-10-01

    Liability aspects of home energy rating systems are discussed. An introduction to the rating system concept, including types of rating systems, implementation efforts to date, and possible groups to conduct ratings, is also included. The home energy rating system concept involves the periodic rating of the energy efficiency of residential buildings. The rating can provide a relative indication of a home's energy efficiency and also a quantitative estimate of consumption, fuel cost, or both. Primary attention is given to liability issues associated with developing and performing ratings. Secondary attention is given to possible liability associated with misuse of a rating once it has been performed.

  4. A Lightweight, User-controlled System For The Home

    Directory of Open Access Journals (Sweden)

    Lynne Baillie

    2006-01-01

    Full Text Available This paper explores how we designed, with input from some elderly persons, a multi-agent user-controlled network for the home. The system was designed to support the elderly in living longer at home with minimal support. We describe how our work attempts to tackle issues such as privacy, control of personal space, and enjoyment within the home. As the number of elderly individuals’ increases, a certain amount of information gathering or support may be required to assist the elderly in their homes. However, we strongly believe that we should preserve people’s privacy in their homes and ensure that any artifact we propose is seen as enjoyable, aesthetically pleasing and, most importantly, not stigmatizing. We describe in this paper how a lightweight setup, using a multimodal mobile robot, a PDA, and an interactive television, can assist the elderly in the home in an enjoyable and unobtrusive way.

  5. Research and Development of Information and Communication Technology-based Home Blood Pressure Monitoring from Morning to Nocturnal Hypertension.

    Science.gov (United States)

    Kario, Kazuomi; Tomitani, Naoko; Matsumoto, Yuri; Hamasaki, Haruna; Okawara, Yukie; Kondo, Maiko; Nozue, Ryoko; Yamagata, Hiromi; Okura, Ayako; Hoshide, Satoshi

    2016-01-01

    Asians have specific characteristics of hypertension (HTN) and its relationship with cardiovascular disease. The morning surge in blood pressure (BP) in Asians is more extended, and the association slope between higher BP and the risk for cardiovascular events is steeper in this population than in whites. Thus, 24-hour BP control including at night and in the morning is especially important for Asian patients with HTN. There are 3 components of "perfect 24-hour BP control": the 24-hour BP level, adequate dipping of nocturnal BP (dipper type), and adequate BP variability such as the morning BP surge. The morning BP-guided approach using home BP monitoring (HBPM) is the first step toward perfect 24-hour BP control. After controlling morning HTN, nocturnal HTN is the second target. We have been developing HBPM that can measure nocturnal BP. First, we developed a semiautomatic HBPM device with the function of automatic fixed-interval BP measurement during sleep. In the J-HOP (Japan Morning Surge Home Blood Pressure) study, the largest nationwide home BP cohort, we successfully measured nocturnal home BP using this device with data memory, 3 times during sleep (2, 3, and 4 am), and found that nocturnal home BP is significantly correlated with organ damage independently of office and morning BP values. The second advance was the development of trigger nocturnal BP (TNP) monitoring with an added trigger function that initiates BP measurements when oxygen desaturation falls below a variable threshold continuously monitored by pulse oximetry. TNP can detect the specific nocturnal BP surges triggered by hypoxic episodes in patients with sleep apnea syndrome. We also added the lowest heart rate-trigger function to TNP to detect the "basal nocturnal BP," which is determined by the circulating volume and structural cardiovascular system without any increase in sympathetic tonus. This double TNP is a novel concept for evaluating the pathogenic pressor mechanism of nocturnal BP

  6. Technology for Improving Medication Monitoring in Nursing Homes

    National Research Council Canada - National Science Library

    Lapane, Kate L; Cameron, Kathleen; Feinberg, Janice

    2005-01-01

    .... While clinical informatics systems have focused on the reduction of medication errors at the point of prescribing, dispensing, or administration, few have proposed the use of information technology...

  7. Operations Monitoring Assistant System Design

    Science.gov (United States)

    1986-07-01

    Logic. Artificial Inteligence 25(1)::75-94. January.18. 41 -Nils J. Nilsson. Problem-Solving Methods In Artificli Intelligence. .klcG raw-Hill B3ook...operations monitoring assistant (OMA) system is designed that combines operations research, artificial intelligence, and human reasoning techniques and...KnowledgeCraft (from Carnegie Group), and 5.1 (from Teknowledze). These tools incorporate the best methods of applied artificial intelligence, and

  8. Monitoring system for thermal plasma

    International Nuclear Information System (INIS)

    Romero G, M.; Vilchis P, A.E.

    1999-01-01

    In the Thermal plasma applications laboratory it has been the degradation project of oils for isolation in transformers. These are a very hazardous residues and at this time in the country they are stored in metal barrels. It has been the intention to undergo the oils to plasma for degradate them to non-hazardous residues. The system behavior must be monitored to establish the thermal plasma behavior. (Author)

  9. Energy Doubler cryoloop temperature monitor system

    International Nuclear Information System (INIS)

    Pucci, G.; Howard, D.

    1981-10-01

    The Cryoloop Temperature Monitor System is a fully electronic system designed to monitor temperature at key points in the Energy Doubler cryoloop system. It is used for cryoloop diagnostics, temperature studies, and cooldown valve control

  10. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Science.gov (United States)

    Mortazavi, SMJ; Gholampour, M; Haghani, M; Mortazavi, G; Mortazavi, AR

    2014-01-01

    Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students), blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2) while the phone was ringing. For Control- Repeat group (15 students), two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (|ΔC|) in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors. PMID:25505778

  11. Electromagnetic Radiofrequency Radiation Emitted from GSM Mobile Phones Decreases the Accuracy of Home Blood Glucose Monitors

    Directory of Open Access Journals (Sweden)

    SMJ Mortazavi

    2014-09-01

    Full Text Available Mobile phones are two-way radios that emit electromagnetic radiation in microwave range. As the number of mobile phone users has reached 6 billion, the bioeffects of exposure to mobile phone radiation and mobile phone electromagnetic interference with electronic equipment have received more attention, globally. As self-monitoring of blood glucose can be a beneficial part of diabetes control, home blood glucose testing kits are very popular. The main goal of this study was to investigate if radiofrequency radiation emitted from a common GSM mobile phone can alter the accuracy of home blood glucose monitors. Forty five female nondiabetic students aged 17-20 years old participated in this study. For Control-EMF group (30 students, blood glucose concentration for each individual was measured in presence and absence of radiofrequency radiation emitted by a common GSM mobile phone (HTC touch, Diamond 2 while the phone was ringing. For Control- Repeat group (15 students, two repeated measurements were performed for each participant in the absence of electromagnetic fields. The magnitude of the changes between glucose levels in two repeated measurements (ΔC in Control-Repeat group was 1.07 ± 0.88 mg/dl while this magnitude for Control-EMF group was 7.53 ± 4.76 mg/dl (P < 0.001, two-tailed test. To the best of our knowledge, this is the first study to assess the electromagnetic interference in home blood glucose monitors. It can be concluded that electromagnetic interference from mobile phones has an adverse effect on the accuracy of home blood glucose monitors. We suggest that mobile phones should be used at least 50 cm away from home blood glucose monitors.

  12. PC based vibration monitoring system

    International Nuclear Information System (INIS)

    Jain, Sanjay K.; Roy, D.A.; Pithawa, C.K.; Patil, R.K.

    2004-01-01

    Health of large rotating machinery gets reflected in the vibration signature of the rotor and supporting structures and proper recording of these signals and their analysis can give a clear picture of the health of the machine. Using these data and their trending, it is possible to predict an impending trouble in the machine so that preventive action can be taken in time and catastrophic failure can be avoided. Continuous monitoring and analysis can give quick warning and enable operator to take preventive measures. Reactor Control Division, BARC is developing a PC based Vibration monitoring system for turbo generator machinery. The System can acquire 20 vibration signals at a rate of 5000 samples per second and also 15 process signals at a rate of 100 samples/ sec. The software for vibration monitoring system includes acquisition modules, analysis modules and Graphical User Interface module. The acquisition module involves initialization, setting of required parameters and acquiring the data from PC-based data acquisition cards. The acquired raw vibration data is then stored for analysis using various software packages. The display and analysis of acquired data is done in LabVIEW 7.0 where the data is displayed in time as well as frequency domain along with the RMS value of the signal. (author)

  13. Uzbekistan Radiation Portal Monitoring System

    International Nuclear Information System (INIS)

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  14. Distributed hierarchical radiation monitoring system

    International Nuclear Information System (INIS)

    Barak, D.

    1985-01-01

    A solution to the problem of monitoring the radiation levels in and around a nuclear facility is presented in this paper. This is a private case of a large scale general purpose data acqisition system with high reliability, availability and short maintenance time. The physical layout of the detectors in the plant, and the strict control demands dictated a distributed and hierarchical system. The system is comprised of three levels, each level contains modules. Level one contains the Control modules which collects data from groups of detectors and executes emergency local control tasks. In level two are the Group controllers which concentrate data from the Control modules, and enable local display and communication. The system computer is in level three, enabling the plant operator to receive information from the detectors and execute control tasks. The described system was built and is operating successfully for about two years. (author)

  15. Smart home-based health platform for behavioral monitoring and alteration of diabetes patients.

    Science.gov (United States)

    Helal, Abdelsalam; Cook, Diane J; Schmalz, Mark

    2009-01-01

    Researchers and medical practitioners have long sought the ability to continuously and automatically monitor patients beyond the confines of a doctor's office. We describe a smart home monitoring and analysis platform that facilitates the automatic gathering of rich databases of behavioral information in a manner that is transparent to the patient. Collected information will be automatically or manually analyzed and reported to the caregivers and may be interpreted for behavioral modification in the patient. Our health platform consists of five technology layers. The architecture is designed to be flexible, extensible, and transparent, to support plug-and-play operation of new devices and components, and to provide remote monitoring and programming opportunities. The smart home-based health platform technologies have been tested in two physical smart environments. Data that are collected in these implemented physical layers are processed and analyzed by our activity recognition and chewing classification algorithms. All of these components have yielded accurate analyses for subjects in the smart environment test beds. This work represents an important first step in the field of smart environment-based health monitoring and assistance. The architecture can be used to monitor the activity, diet, and exercise compliance of diabetes patients and evaluate the effects of alternative medicine and behavior regimens. We believe these technologies are essential for providing accessible, low-cost health assistance in an individual's own home and for providing the best possible quality of life for individuals with diabetes. © Diabetes Technology Society

  16. Potential of solar home systems in Pakistan

    International Nuclear Information System (INIS)

    Memon, M.; Harijan, K.; Uqaili, M. A.

    2007-01-01

    About 68% of the population of Pakistan resides in rural areas. Most of the rural households have no access to electricity and meet lighting requirements through kerosene which is a major source of indoor air pollution and other environmental and health hazards. Rural villages are scattered over a large area and located far from the main electric grids. They have low population density and requires small load. About 67% of the conventional electricity in Pakistan is generated from fossil fuels with 51% and 16% share of gas and oil respectively. The indigenous reserves of oil and gas are limited and the country heavily depends on imported oil. The oil import bill is a serious strain on the country's economy. The combustion of fossil fuels also causes serious environmental pollution. The conventional power is even not sufficient for meeting the growing demand of electricity from the existing customers. Further more the extension of existing centralized grid system to far away from grid line rural areas with very low population density and small-scattered loads are economically and technically unfeasible. Hence there are remote chances of getting grid connection to most of the rural population in the near future. This whole situation requires urgent measures on priority basis for the development of indigenous, environment friendly, renewable energy sources such as solar energy. This paper presents the assessment of potential of solar home systems (SHS) for rural electrification in Pakistan. The country lies in an excellent solar belt range and receives 16-21 MJ/m 2 per day of solar radiation as an annual mean value, with 19 MJ/m 2 per day over most areas of the country. It is estimated that about 7 million households in Pakistan do not have access to electricity (in 2004). Assuming that about 50% of the households in rural areas without electricity today would be electrified up to 2010, and only 25% of the remaining households could afford and would be willing to pay

  17. Intelligent home risk assessment systems and integration with biometric identification

    Science.gov (United States)

    Roper, William E.

    2003-08-01

    An overview is given of the Home of the 21st Century Laboratory. The laboratory is operated as a joint program with America-On-Line and George Washington University. The program is described with illustrations and discussion of the systems that are part of the laboratory. The concept of application for face recognition systems in the intelligent home of the future is presented and some initial approaches in using biometrics are shown. Issues of privacy and sharing of information within and outside the home are addressed. Issues include safety and security concerns vs. inappropriate observations of activities in and outside the home. Technology options currently available for application in the home are described and assessed.

  18. Smart Homes with Voice Activated Systems for Disabled People

    Directory of Open Access Journals (Sweden)

    Bekir Busatlic

    2017-02-01

    Full Text Available Smart home refers to the application of various technologies to semi-unsupervised home control It refers to systems that control temperature, lighting, door locks, windows and many other appliances. The aim of this study was to design a system that will use existing technology to showcase how it can benefit people with disabilities. This work uses only off-the-shelf products (smart home devices and controllers, speech recognition technology, open-source code libraries. The Voice Activated Smart Home application was developed to demonstrate online grocery shopping and home control using voice comments and tested by measuring its effectiveness in performing tasks as well as its efficiency in recognizing user speech input.

  19. Fall Down Detection Under Smart Home System.

    Science.gov (United States)

    Juang, Li-Hong; Wu, Ming-Ni

    2015-10-01

    Medical technology makes an inevitable trend for the elderly population, therefore the intelligent home care is an important direction for science and technology development, in particular, elderly in-home safety management issues become more and more important. In this research, a low of operation algorithm and using the triangular pattern rule are proposed, then can quickly detect fall-down movements of humanoid by the installation of a robot with camera vision at home that will be able to judge the fall-down movements of in-home elderly people in real time. In this paper, it will present a preliminary design and experimental results of fall-down movements from body posture that utilizes image pre-processing and three triangular-mass-central points to extract the characteristics. The result shows that the proposed method would adopt some characteristic value and the accuracy can reach up to 90 % for a single character posture. Furthermore the accuracy can be up to 100 % when a continuous-time sampling criterion and support vector machine (SVM) classifier are used.

  20. Coolant monitoring systems for PWR reactors

    International Nuclear Information System (INIS)

    Luzhnov, A.M.; Morozov, V.V.; Tsypin, S.G.

    1987-01-01

    The ways of improving information capacity of existing monitoring systems and the necessity of designing new ones for coolant monitoring are reviewed. A wide research program on development of coolant monitoring systems in PWR reactors is analyzed. The possible applications of in-core and out-of-core detectors for coolant monitoring are demonstrated

  1. A sensor monitoring system for telemedicine, safety and security applications

    Science.gov (United States)

    Vlissidis, Nikolaos; Leonidas, Filippos; Giovanis, Christos; Marinos, Dimitrios; Aidinis, Konstantinos; Vassilopoulos, Christos; Pagiatakis, Gerasimos; Schmitt, Nikolaus; Pistner, Thomas; Klaue, Jirka

    2017-02-01

    A sensor system capable of medical, safety and security monitoring in avionic and other environments (e.g. homes) is examined. For application inside an aircraft cabin, the system relies on an optical cellular network that connects each seat to a server and uses a set of database applications to process data related to passengers' health, safety and security status. Health monitoring typically encompasses electrocardiogram, pulse oximetry and blood pressure, body temperature and respiration rate while safety and security monitoring is related to the standard flight attendance duties, such as cabin preparation for take-off, landing, flight in regions of turbulence, etc. In contrast to previous related works, this article focuses on the system's modules (medical and safety sensors and associated hardware), the database applications used for the overall control of the monitoring function and the potential use of the system for security applications. Further tests involving medical, safety and security sensing performed in an real A340 mock-up set-up are also described and reference is made to the possible use of the sensing system in alternative environments and applications, such as health monitoring within other means of transport (e.g. trains or small passenger sea vessels) as well as for remotely located home users, over a wired Ethernet network or the Internet.

  2. A Human-Centered Smart Home System with Wearable-Sensor Behavior Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Jianting; Liu, Ting; Shen, Chao; Wu, Hongyu; Liu, Wenyi; Su, Man; Chen, Siyun; Jia, Zhanpei

    2016-11-17

    Smart home has recently attracted much research interest owing to its potential in improving the quality of human life. How to obtain user's demand is the most important and challenging task for appliance optimal scheduling in smart home, since it is highly related to user's unpredictable behavior. In this paper, a human-centered smart home system is proposed to identify user behavior, predict their demand and schedule the household appliances. Firstly, the sensor data from user's wearable devices are monitored to profile user's full-day behavior. Then, the appliance-demand matrix is constructed to predict user's demand on home environment, which is extracted from the history of appliance load data and user behavior. Two simulations are designed to demonstrate user behavior identification, appliance-demand matrix construction and strategy of appliance optimal scheduling generation.

  3. Home Automated Telemanagement (HAT System to Facilitate Self-Care of Patients with Chronic Diseases

    Directory of Open Access Journals (Sweden)

    Joseph Finkelstein

    2003-06-01

    Full Text Available Successful patient self-management requires a multidisciplinary approach that includes regular patient assessment, disease-specific education, control of medication adherence, implementation of health behavior change models and social support. Existing systems for computer-assisted disease management do not provide this multidisciplinary patient support and do not address treatment compliance issues. We developed the Home Automated Telemanagement (HAT system for patients with different chronic health conditions to facilitate their self-care. The HAT system consists of a home unit, HAT server, and clinician units. Patients at home use a palmtop or a laptop connected with a disease monitor on a regular basis. Each HAT session consists of self-testing, feedback, and educational components. The self-reported symptom data and objective results obtained from disease-specific sensors are automatically sent from patient homes to the HAT server in the hospital. Any web-enabled device can serve as a clinician unit to review patient results. The HAT system monitors self-testing results and patient compliance. The HAT system has been implemented and tested in patients receiving anticoagulation therapy, patients with asthma, COPD and other health conditions. Evaluation results indicated high level of acceptance of the HAT system by the patients and that the system has a positive impact on main clinical outcomes and patient satisfaction with medical care.

  4. Implementing monitoring technologies in care homes for people with dementia: A qualitative exploration using Normalization Process Theory.

    Science.gov (United States)

    Hall, Alex; Wilson, Christine Brown; Stanmore, Emma; Todd, Chris

    2017-07-01

    Ageing societies and a rising prevalence of dementia are associated with increasing demand for care home places. Monitoring technologies (e.g. bed-monitoring systems; wearable location-tracking devices) are appealing to care homes as they may enhance safety, increase resident freedom, and reduce staff burden. However, there are ethical concerns about the use of such technologies, and it is unclear how they might be implemented to deliver their full range of potential benefits. This study explored facilitators and barriers to the implementation of monitoring technologies in care homes. Embedded multiple-case study with qualitative methods. Three dementia-specialist care homes in North-West England. Purposive sample of 24 staff (including registered nurses, clinical specialists, senior managers and care workers), 9 relatives and 9 residents. 36 semi-structured interviews with staff, relatives and residents; 175h of observation; resident care record review. Data collection informed by Normalization Process Theory, which seeks to account for how novel interventions become routine practice. Data analysed using Framework Analysis. Findings are presented under three main themes: 1. Reasons for using technologies: The primary reason for using monitoring technologies was to enhance safety. This often seemed to override consideration of other potential benefits (e.g. increased resident freedom) or ethical concerns (e.g. resident privacy); 2. Ways in which technologies were implemented: Some staff, relatives and residents were not involved in discussions and decision-making, which seemed to limit understandings of the potential benefits and challenges from the technologies. Involvement of residents appeared particularly challenging. Staff highlighted the importance of training, but staff training appeared mainly informal which did not seem sufficient to ensure that staff fully understood the technologies; 3. Use of technologies in practice: Technologies generated frequent

  5. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2014-02-01

    This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

  6. INFN-CNAF Monitor and Control System

    International Nuclear Information System (INIS)

    Antonelli, Stefano; De Girolamo, Donato; Dell'Agnello, Luca; Gregori, Daniele; Guizzunti, Guido; Ricci, Pier Paolo; Rosso, Felice; Sapunenko, Vladimir; Veraldi, Riccardo; Veronesi, Paolo; Vistoli, Cristina; Finzi, Giulia Vita; Zani, Stefano

    2011-01-01

    CNAF is the national center of National Institute of Nuclear Physics (INFN) for R and D in the field of Information Technologies applied to High Energy Physics (HEP) experiments. It is involved in the management and development of the most important information and data handling services in behalf of the INFN. In 2005, the Italian Tier-1 for Large Hadron Collider (LHC) experiments has been inaugurated at INFN-CNAF. Due to the huge complexity of Tier-1 center, the use of control systems is fundamental for management and operation of the center. At INFN-CNAF, several solutions have been adopted, from commercial to open source products up to entirely home-made systems. Adopted open source solutions have been strongly adapted to specific needs; a wide set of customized sensors has been developed for various divisions like Network, Storage, Farming, Grid operation and National Services. Finally, a dashboard has been developed, to which described control systems send critical alarms (sent via sms to an operator as well). The dashboard can be exploited to get an historical view of the Tier-1 and national services' state and to allow a quick web control. In this article, the whole system, adopted customizations in monitoring and control as well as their integrations with the dashboard will be described.

  7. Fuzzy-Logic Subsumption Controller for Home Energy Management Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ainsworth, Nathan; Johnson, Brian; Lundstrom, Blake

    2015-10-06

    Home Energy Management Systems (HEMS) are controllers that manage and coordinate the generation, storage, and loads in a home. These controllers are increasingly necessary to ensure that increasing penetrations of distributed energy resources are used effectively and do not disrupt the operation of the grid. In this paper, we propose a novel approach to HEMS design based on behavioral control methods, which do not require accurate models or predictions and are very responsive to changing conditions. We develop a proof-of-concept behavioral HEMS controller and show by simulation on an example home energy system that it capable of making context-dependent tradeoffs between goals under challenging conditions.

  8. Intelligent Home Control System Based on ARM10

    Science.gov (United States)

    Chen, G. X.; Jiang, J.; Zhong, L. H.

    2017-10-01

    Intelligent home is becoming the hot spot of social attention in the 21st century. When it is in China, it is a really new industry. However, there is no doubt that Intelligent home will become a new economic growth point of social development; it will change the life-style of human being. To develop the intelligent home, we should keep up with the development trend of technology. This is the reason why I talk about the intelligent home control system here. In this paper, intelligent home control system is designed for alarm and remote control on gas- leaking, fire disaster, earthquake prediction, etc., by examining environmental changes around house. When the Intelligent home control system has detected an accident occurs, the processor will communicate with the GSM module, informing the house keeper the occurrence of accident. User can receive and send the message to the system to cut the power by mobile phone. The system can get access to DCCthrough ARM10 JTAG interface, using DCC to send and receive messages. At the same time, the debugger on the host is mainly used to receive the user’s command and send it to the debug component in the target system. The data that returned from the target system is received and displayed to the user in a certain format.

  9. Battery Monitoring and Charging System

    National Research Council Canada - National Science Library

    Thivierge, Daniel P

    2007-01-01

    A battery monitoring device for a battery having cells grouped in modules. The device includes a monitoring circuit for each module which monitors the voltage in each cell and the overall module voltage...

  10. Monitoring Systems for Hydropower Plants

    Directory of Open Access Journals (Sweden)

    Damaschin Pepa

    2015-07-01

    Full Text Available One of the most important issue in hydro power industry is to determine the necessary degree of automation in order to improve the operation security. Depending upon the complexity of the system (the power plant equipment the automation specialist will build a philosophy of control following some general principals of security and operation. Helped by the modern digital equipment, today is relative easy to design a complete monitoring and supervising system including all the subparts of a hydro aggregate. A series of sensors and transducers specific for each auxiliary installation of the turbine and generator will be provided, together with a PLC or an industrial PC that will run an application software for implementing the security and control algorithms. The purpose of this paper is to offer a general view of these issues, providing a view of designing an automation & control and security system for hydro power plants of small, medium and big power.

  11. Radiation monitoring system for astronauts

    International Nuclear Information System (INIS)

    Thomson, I.; MacKay, G.; Ng, A.; Tomi, L.

    1996-01-01

    Astronauts in space are constantly under the bombardment of radiation particles from trapped electrons, and trapped proton. In addition, cosmic rays, while penetrating the spacecraft shell, generate secondary radiation of neutrons. As astronauts' stay in space is getting longer, the need for a real-time radiation monitoring device has become critical. Thermoluminescent dosemeter (TLD), used onboard both the MIR and the Space Transportation System (STS), cannot provide real-time dose reading. This paper describes a real-time direct read-out device, currently under development, which can measure skin, eye, and Blood Forming Organ (BFO) doses separately. (author)

  12. The perceptions of cognitively impaired patients and their caregivers of a home telecare system.

    Science.gov (United States)

    Mehrabian, Shima; Extra, Jocelyne; Wu, Ya-Huei; Pino, Maribel; Traykov, Latchezar; Rigaud, Anne-Sophie

    2015-01-01

    Assistive and telecare technologies have been developed to support older adults with cognitive impairments, as well as their caregivers, from their homes. The way potential users perceive telecare and smart home systems plays a key role in their acceptance of this new technology. We evaluate the acceptance of home telecare technologies among patients suffering from cognitive impairment and their caregivers. Prototypes of telecare devices were developed to demonstrate their features and capabilities and to train patients, families, and health care professionals in their use. We conducted semistructured interviews to elicit the perceptions of 30 patients with mild cognitive impairment, 32 patients with Alzheimer's disease, and 30 caregivers, regarding the risks and advantages of home telecare and smart houses. Survey results reflected participants' largely positive reactions to these technologies. Regarding home telecare, the cognitive stimulation program earned the highest proportion of positive responses, followed by the devices' care of emergencies. The participants generally agreed that home telecare and smart houses could significantly improve their quality of life. However, some technical and ethical concerns, such as the way of provision, installation, and monitoring of the systems, were reported to be in need of addressing before implementation of this system.

  13. A telemedicine instrument for Internet-based home monitoring of thoracoabdominal motion in patients with respiratory diseases

    Science.gov (United States)

    da Silva Junior, Evert Pereira; Esteves, Guilherme Pompeu; Dames, Karla Kristine; Melo, Pedro Lopes de

    2011-01-01

    Changes in thoracoabdominal motion are highly prevalent in patients with chronic respiratory diseases. Home care services that use telemedicine techniques and Internet-based monitoring have the potential to improve the management of these patients. However, there is no detailed description in the literature of a system for Internet-based monitoring of patients with disturbed thoracoabdominal motion. The purpose of this work was to describe the development of a new telemedicine instrument for Internet-based home monitoring of thoracoabdominal movement. The instrument directly measures changes in the thorax and abdomen circumferences and transfers data through a transmission control protocol/Internet protocol connection. After the design details are described, the accuracy of the electronic and software processing units of the instrument is evaluated by using electronic signals simulating normal subjects and individuals with thoracoabdominal motion disorders. The results obtained during in vivo studies on normal subjects simulating thoracoabdominal motion disorders showed that this new system is able to detect a reduction in abdominal movement that is associated with abnormal thoracic breathing (p telemedicine scenarios, which can reduce the costs of assistance offered to patients with respiratory diseases.

  14. Instrumentation for Power System Disturbance Monitoring, Data ...

    African Journals Online (AJOL)

    In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...

  15. Calibration method of radiation monitoring system at TQNPC

    International Nuclear Information System (INIS)

    Liu Zhengshan; Zhang Qingli; Liu Jinjin; Miao Yuxing; Geng Lixin; Zhuang Yun; Dong Jianfeng; He Change

    2009-04-01

    The calibration methods and calibration device for standard monitor of radioactive particulate, iodine, noble gas and so on are not yet set up at home. On consideration of the present situation of the radiation monitoring system at the Third Qinshan Nuclear Power Co. Ltd., we have studied the calibration method of these radiation monitoring instruments used for measuring the waste liquid, particulate, iodine and noble gas produced during the operation of nuclear reactor. Through the check against these instruments during the No. 202 and No. 103 overhaul, we got initially the method of the calibration and obtained the transfer coefficient of calibration when secondary solid sources are used for calibration. Through the testing and calibration, the credibility of the radiation monitoring system is enhanced. And at the same time, the problems existing in the calibration are discussed. (authors)

  16. Monitoring of Danish marketed solar heating systems

    International Nuclear Information System (INIS)

    Ellehauge, K.

    1993-01-01

    The paper describes the monitoring of manufactured solar heating systems for domestic hot water combined with space heating and systems for domestic hot water only. Results from the monitoring of 5 marketed combined systems for domestic hot water and space heating are presented. The systems situated at one family houses at different sites in Denmark have been monitored from January/February 1992. For the detailed monitoring of manufactured systems only for domestic hot water a test facility for simultaneous monitoring of 5 solar heating systems has been established at the Thermal Insulation Laboratory. (au)

  17. Using preventive home monitoring to reduce hospital admission rates and reduce costs

    DEFF Research Database (Denmark)

    Dinesen, Birthe Irene; Haesum, Lisa K E; Soerensen, Natascha

    2012-01-01

    We studied whether preventive home monitoring of patients with chronic obstructive pulmonary disease (COPD) could reduce the frequency of hospital admissions and lower the cost of hospitalization. Patients were recruited from a health centre, general practitioner (GP) or the pulmonary hospital ward....... They were randomized to usual care or tele-rehabilitation with a telehealth monitoring device installed in their home for four months. A total of 111 patients were suitable for inclusion and consented to be randomized: 60 patients were allocated to intervention and three were lost to follow...... of admissions was €3461 per patient in the intervention group and €4576 in the control group; this difference was not significant. The Kaplan-Meier estimates for time to hospital admission were longer for the intervention group than the controls, but the difference was not significant. Future work requires...

  18. Design of acoustic emission monitoring system based on VC++

    Science.gov (United States)

    Yu, Yang; He, Wei

    2015-12-01

    At present, a lot of companies at home and abroad have researched and produced a batch of specialized monitoring instruments for acoustic emission (AE). Most of them cost highly and the system function exists in less stable and less portability for the testing environment and transmission distance and other aspects. Depending on the research background and the status quo, a dual channel intelligent acoustic emission monitoring system was designed based on Microsoft Foundation Classes in Visual Studio C++ to solve some of the problems in the acoustic emission research and meet the needs of actual monitoring task. It contains several modules such as main module, acquisition module, signal parameters setting module and so on. It could give out corrosion AE waveform and signal parameters results according to the main menu selected parameters. So the needed information could be extracted from the experiments datum to solve the problem deeply. This soft system is the important part of AE detection g system.

  19. Home Dialysis in the Prospective Payment System Era.

    Science.gov (United States)

    Lin, Eugene; Cheng, Xingxing S; Chin, Kuo-Kai; Zubair, Talhah; Chertow, Glenn M; Bendavid, Eran; Bhattacharya, Jayanta

    2017-10-01

    The ESRD Prospective Payment System introduced two incentives to increase home dialysis use: bundling injectable medications into a single payment for treatment and paying for home dialysis training. We evaluated the effects of the ESRD Prospective Payment System on home dialysis use by patients starting dialysis in the United States from January 1, 2006 to August 31, 2013. We analyzed data on dialysis modality, insurance type, and comorbidities from the United States Renal Data System. We estimated the effect of the policy on home dialysis use with multivariable logistic regression and compared the effect on Medicare Parts A/B beneficiaries with the effect on patients with other types of insurance. The ESRD Prospective Payment System associated with a 5.0% (95% confidence interval [95% CI], 4.0% to 6.0%) increase in home dialysis use by the end of the study period. Home dialysis use increased by 5.8% (95% CI, 4.3% to 6.9%) among Medicare beneficiaries and 4.1% (95% CI, 2.3% to 5.4%) among patients covered by other forms of health insurance. The difference between these groups was not statistically significant (1.8%; 95% CI, -0.2% to 3.8%). Conversely, in both populations, the training add-on did not associate with increases in home dialysis use beyond the effect of the policy. The ESRD Prospective Payment System bundling, but not the training add-on, associated with substantial increases in home dialysis, which were identical for both Medicare and non-Medicare patients. These spill-over effects suggest that major payment changes in Medicare can affect all patients with ESRD. Copyright © 2017 by the American Society of Nephrology.

  20. A real time monitoring system

    International Nuclear Information System (INIS)

    Fontanini, Horacio; Galdoz, Erwin

    1989-01-01

    A real time monitoring system is described. It was initially developed to be used as a man-machine interface between a basic principles simulator of the Embalse Nuclear Power Plant and the operators. This simulator is under construction at the Bariloche Atomic Center's Process Control Division. Due to great design flexibility, this system can also be used in real plants. The system is designed to be run on a PC XT or AT personal computer with high resolution graphics capabilities. Three interrelated programs compose the system: 1) Graphics Editor, to build static image to be used as a reference frame where to show dynamically updated data. 2) Data acquisition and storage module. It is a memory resident module to acquire and store data in background. Data can be acquired and stored without interference with the operating system, via serial port or through analog-to-digital converter attached to the personal computer. 3) Display module. It shows the acquired data according to commands received from configuration files prepared by the operator. (Author) [es

  1. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  2. Automated Cognitive Health Assessment Using Smart Home Monitoring of Complex Tasks.

    Science.gov (United States)

    Dawadi, Prafulla N; Cook, Diane J; Schmitter-Edgecombe, Maureen

    2013-11-01

    One of the many services that intelligent systems can provide is the automated assessment of resident well-being. We hypothesize that the functional health of individuals, or ability of individuals to perform activities independently without assistance, can be estimated by tracking their activities using smart home technologies. In this paper, we introduce a machine learning-based method for assessing activity quality in smart homes. To validate our approach we quantify activity quality for 179 volunteer participants who performed a complex, interweaved set of activities in our smart home apartment. We observed a statistically significant correlation (r=0.79) between automated assessment of task quality and direct observation scores. Using machine learning techniques to predict the cognitive health of the participants based on task quality is accomplished with an AUC value of 0.64. We believe that this capability is an important step in understanding everyday functional health of individuals in their home environments.

  3. Electronic Control System Of Home Appliances Using Speech Command Words

    Directory of Open Access Journals (Sweden)

    Aye Min Soe

    2015-06-01

    Full Text Available Abstract The main idea of this paper is to develop a speech recognition system. By using this system smart home appliances are controlled by spoken words. The spoken words chosen for recognition are Fan On Fan Off Light On Light Off TV On and TV Off. The input of the system takes speech signals to control home appliances. The proposed system has two main parts speech recognition and smart home appliances electronic control system. Speech recognition is implemented in MATLAB environment. In this process it contains two main modules feature extraction and feature matching. Mel Frequency Cepstral Coefficients MFCC is used for feature extraction. Vector Quantization VQ approach using clustering algorithm is applied for feature matching. In electrical home appliances control system RF module is used to carry command signal from PC to microcontroller wirelessly. Microcontroller is connected to driver circuit for relay and motor. The input commands are recognized very well. The system is a good performance to control home appliances by spoken words.

  4. A prospective study of the impact of home monitoring on the family.

    Science.gov (United States)

    Wasserman, A L

    1984-09-01

    Fourteen families whose infants required home monitoring for apnea were followed for approximately 5 years from the initial contact (1977). Each family received at least three psychiatric interviews and two follow-up contacts. Effects on the monitored infant, siblings, and parents were examined in open and semi-structured interviews. At first follow-up (mean of 21 months after monitoring discontinuance), seven of 14 monitored children were characterized as spoiled by parents. By the second follow-up, 2 1/2 years later, nine children showed speech, learning, and motor problems; five of these nine children had required resuscitation during their initial episode. Apnea severity was also related to both duration of monitoring and number of additional psychiatric interviews requested by parents or staff. Of 16 older siblings, 12 had psychological problems reported by their parents at first follow-up; these problems appeared to be largely resolved by the second follow-up, although three children were still having problems that caused parental concern. Monitoring, as well as the apnea itself, caused substantial distress manifested in depression, fatigue, and anxiety in many parents, particularly mothers. However, despite their considerable distress, none of the families discontinued monitoring prematurely. Results of the study indicated that the monitoring experience can be divided into four phases: doubt/acceptance, dependence/frustration, discontinuance, and late effects, with substantial differences in parents' responses occurring only in the last two phases.

  5. Plant operation state monitoring system

    International Nuclear Information System (INIS)

    Sakai, Masanori; Babuchi, Katsumi; Arato, Toshiaki

    1994-01-01

    The system of the present invention accurately monitors a plant operation state of a plant, such as a nuclear power plant and a thermal power plant by using high temperature water, based on water quality informations. That is, water quality informations for the objective portion by using an electrochemical water quality sensor disposed in the objective portion to be monitored in the plant are continuously extracted for a predetermined period of time. Water quality is evaluated based on the extracted information. Obtained results for water quality evaluation and predetermined reference values of the plant operation handling are compared. Necessary part among the results of the measurement is displayed or recorded. The predetermined period of time described above is a period that the water quality information reaches at least a predetermined value or a period that the predetermined value is estimated by the water quality information, and it is defined as a period capable of measuring the information for three months continuously. The measurement is preferably conducted continuously in a period up to each periodical inspection on about every one year. (I.S.)

  6. The Embedded Smart Home Control System Based on GPRS and Zigbee

    Directory of Open Access Journals (Sweden)

    Zhang Wanli

    2015-01-01

    Full Text Available With the development of the Internet of Things and mobile Internet, smart home appeared a new opportunity, the development of wireless communication, ad-hoc network technique, high reliable connection, large scale networking, repair itself as a new developing direction of smart home. This paper discussed hardware and software design of the embedded smart home control system based on GPRS transmission network and Zigbee technology. This paper also expounds the composition structure and working principle of the system. Through the Zigbee technology to realize the ad-hoc network among the main controller and Zigbee terminal nodes, realizes the branch node information acquisition and command transmission. Through the GPRS network mobile client can realize information collection and remote monitoring of household facilities.

  7. A unique radiation area monitoring system

    International Nuclear Information System (INIS)

    Murphy, P.C.; Allen, G.C.

    1978-01-01

    The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area

  8. Radiation monitor system for nuclear power plants

    International Nuclear Information System (INIS)

    Wu Bingzhe; Guo Shusheng

    1990-12-01

    The system has 8 kinds of radiation monitors and 2 stage microcomputers designed for processing the data from each monitor, storaging the information, printing out and displaying on the colour CRT. The function of the system includes high-value alarm, warm alarm and failure alarm, so called t hree-level alarms . Two functions of the alarms are the threshold alarm and the tendency alarm, so that this system is an intelligency system. This system has high reliability and very wide range when LOCA accident takes place. It is aseismic and immune to industrial interference. The system can meet IEC-761-1 standard and is of nuclear safety 3rd class. Also the following monitors were designed: 133 Xe monitor, 131 I monitor, low-level liquid monitor and high radiation γ area monitor. The system can meet the requirements of nuclear power plants

  9. Wireless Home Automation System using IoT

    Directory of Open Access Journals (Sweden)

    Alexandra MIHALACHE

    2017-01-01

    Full Text Available Nowadays, the chance of having an automated home is no longer a fancy luxury, but a reality accessible to a wide range of consumers, because smart home systems have replaced those that only automated the home in the past. More and more solutions based on IoT are being devel-oped to transform homes into smart ones, but the problem is that the benefits of home automa-tion are still not clear to everyone as they are not promoted enough, so we cannot talk about a broad mass of consumers already using integrated or DIY solutions to improve their lives. In this paper, I will present a home automation system using Arduino Uno integrated with rele-vant modules which are used to allow remote control of lights or fans, changes being made on the basis of different sensors data. The system is designed to be low cost and expandable, bring-ing accessibility, convenience and energy efficiency.

  10. Smart sensor systems for human health breath monitoring applications.

    Science.gov (United States)

    Hunter, G W; Xu, J C; Biaggi-Labiosa, A M; Laskowski, D; Dutta, P K; Mondal, S P; Ward, B J; Makel, D B; Liu, C C; Chang, C W; Dweik, R A

    2011-09-01

    Breath analysis techniques offer a potential revolution in health care diagnostics, especially if these techniques can be brought into standard use in the clinic and at home. The advent of microsensors combined with smart sensor system technology enables a new generation of sensor systems with significantly enhanced capabilities and minimal size, weight and power consumption. This paper discusses the microsensor/smart sensor system approach and provides a summary of efforts to migrate this technology into human health breath monitoring applications. First, the basic capability of this approach to measure exhaled breath associated with exercise physiology is demonstrated. Building from this foundation, the development of a system for a portable asthma home health care system is described. A solid-state nitric oxide (NO) sensor for asthma monitoring has been identified, and efforts are underway to miniaturize this NO sensor technology and integrate it into a smart sensor system. It is concluded that base platform microsensor technology combined with smart sensor systems can address the needs of a range of breath monitoring applications and enable new capabilities for healthcare.

  11. Automatic Energy Control And Monitoring System For Building

    Directory of Open Access Journals (Sweden)

    Hnin Nu Thaung

    2015-08-01

    Full Text Available The use of smart home technology in the home or building offers significant potential for energy savings. In this paper an energy management system based on wireless sensor networks. The proposed system is composed of two main components a wireless sensor network and monitoring terminal. Wireless sensors are used for sensing and transmitting electricity data and remote monitoring and control of appliances are provided to users through computer. The system enables users to save energy by monitoring and controlling appliances through terminal. This paper gives an overview of sensor technology and wireless networks in the development of an intelligent energy management system for buildings. This technology has ample potential to change the way live and work. ZigBee is used as a communication medium in building intelligent energy management system in this paper. From the prototype setup it is shown that ZigBee is a suitable technology to be adopted as the communication infrastructure in energy management system for buildings .The proposed system can be installed and maintained in residential environments with ease.

  12. Stack Monitoring System At PUSPATI TRIGA Reactor

    International Nuclear Information System (INIS)

    Zamrul Faizad Omar; Mohd Sabri Minhat; Zareen Khan Abdul Jalil Khan; Ridzuan Abdul Mutalib; Khairulezwan Abdul Manan; Nurfarhana Ayuni Joha; Izhar Abu Hussin

    2014-01-01

    This paper describes the current Stack Monitoring System at PUSPATI TRIGA Reactor (RTP) building. A stack monitoring system is a continuous air monitor placed at the reactor top for monitoring the presence of radioactive gaseous in the effluent air from the RTP building. The system consists of four detectors that provide the reading for background, particulate, Iodine and Noble gas. There is a plan to replace the current system due to frequent fault of the system, thus thorough understanding of the current system is required. Overview of the whole system will be explained in this paper. Some current results would be displayed and moving forward brief plan would be mentioned. (author)

  13. Offsite emergency radiological monitoring system and technology

    International Nuclear Information System (INIS)

    Mao Yongze

    1994-01-01

    The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries

  14. The feasibility of home monitoring of impedance with the forced oscillation technique in chronic obstructive pulmonary disease subjects

    International Nuclear Information System (INIS)

    Timmins, Sophie C; Diba, Chantale; Thamrin, Cindy; Berend, Norbert; Salome, Cheryl M; King, Gregory G

    2013-01-01

    Respiratory system resistance (Rrs) and reactance (Xrs) measured by forced oscillation technique (FOT) can be potentially used for home monitoring in COPD. Our aims were to determine the technical acceptability, adherence and variability of unsupervised, home FOT measurements over ten consecutive days. Supervised spirometry and FOT measurements were made on ten clinically stable COPD subjects at their homes at the study initiation. Subjects then self-recorded FOT twice daily for ten consecutive days with data transmitted to the laboratory server via a 3G mobile network. Subjects had a mean (SD) age of 68(8) years, smoking history 38.4(8.7) pack/years, post-bronchodilator FEV1 42.4(12.0)% predicted, FEV1/FVC ratio 0.45(0.10), mean Rrs 121.7(26.1)% predicted and mean Xrs 746.8(330.3)% predicted. The supervised measurements of mean Rrs and mean Xrs were similar to the unsupervised measurements (p = 0.34 and p = 0.92, respectively). 197 of 200 possible measurements were transmitted, all of which were deemed to be technically acceptable. The within-subject standard deviation, Sw, of Rrs-total and Xrs-total were 0.47 and 1.0 cmH 2 O L s –1 , respectively. Subjects who have COPD make reliable, unsupervised FOT measurements at home with a high degree of adherence. The day-to-day variability of FOT measurements was similar to that of supervised laboratory recordings. These results support the conduct of larger, longer-term studies of FOT monitoring in COPD. (paper)

  15. Smart Security System For Home Appliances Control Based On Internet Of Things

    Directory of Open Access Journals (Sweden)

    Su Zin Zin Win

    2015-08-01

    Full Text Available Technology is always evolves. Home security is essential for occupants convenience and protection. Security systems are being preferred over manual system. With the rapid increase in the number of users of internet over the past decade has made Internet a part and parcel of life and IoTs is the latest and emerging internet technology. Home Appliances Control of Smart Security System using IoTs uses computers or mobile devices to control basic home functions and features through internet from anywhere around the world. This security system differs from other system by allowing the user to operate the system from anywhere around the world through internet connection. With the implementation of Arduino Mega microcontroller as an Embedded device security system design was constructed with many sensors and web server database. The Arduino Ethernet shield is used to eliminate the use of a personal computer PC. The motion sensing circuit temperature and humidity sensing circuit smoke or gas sensing circuit door lock sensing circuit light onoff circuit were designed to be connected with Arduino Mega microcontroller and Ethernet shield. This system can monitor the temperature and humidity values and the state of some sensors for intruder detection. It can also control the electric appliances like lights and door at home. Real time result was displayed on web server page via the internet.

  16. Perceptions of seniors with heart failure regarding autonomous zero-effort monitoring of physiological parameters in the smart-home environment.

    Science.gov (United States)

    Grace, Sherry L; Taherzadeh, Golnoush; Jae Chang, Isaac Sung; Boger, Jennifer; Arcelus, Amaya; Mak, Susanna; Chessex, Caroline; Mihailidis, Alex

    Technological advances are leading to the ability to autonomously monitor patient's health status in their own homes, to enable aging-in-place. To understand the perceptions of seniors with heart failure (HF) regarding smart-home systems to monitor their physiological parameters. In this qualitative study, HF outpatients were invited to a smart-home lab, where they completed a sequence of activities, during which the capacity of 5 autonomous sensing modalities was compared to gold standard measures. Afterwards, a semi-structured interview was undertaken. These were transcribed and analyzed using an interpretive-descriptive approach. Five themes emerged from the 26 interviews: (1) perceptions of technology, (2) perceived benefits of autonomous health monitoring, (3) disadvantages of autonomous monitoring, (4) lack of perceived need for continuous health monitoring, and (5) preferences for autonomous monitoring. Patient perception towards autonomous monitoring devices was positive, lending credence to zero-effort technology as a viable and promising approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Project W-420 stack monitoring system upgrades

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This project will execute the design, procurement, construction, startup, and turnover activities for upgrades to the stack monitoring system on selected Tank Waste Remediation System (TWRS) ventilation systems. In this plan, the technical, schedule, and cost baselines are identified, and the roles and responsibilities of project participants are defined for managing the Stack Monitoring System Upgrades, Project W-420

  18. Acoustic emission leak monitoring system LMS-96

    International Nuclear Information System (INIS)

    Liska, J.; Cvrcek, M.; Mueller, L.

    1997-01-01

    On-line acoustic emission leak monitoring under industrial conditions of nuclear power plants is a problem with specific features setting specific demands on the leak monitoring system. The paper briefly reviews those problems (attenuation pattern of a real structure, acoustic background, alarm system, etc.) and the solution of some of them is discussed. Information is presented on the Acoustic Emission Leak Monitoring System LMS-96 by SKODA NUCLEAR MACHINERY and the system's function is briefly described. (author)

  19. Design and Construction of a Home Automation System Using a ...

    African Journals Online (AJOL)

    Output units which comprise of the Liquid Crystal Display (LCD) and the relays which powers on and off the fan and bulbs, are incorporated in the circuit to make the results of test visible and complete the system design for the smart home. The result of the test shows that the system automatically switched on and off light ...

  20. Home Energy Systems: the State of the Art

    NARCIS (Netherlands)

    van de Kaa, G.; Ligtvoet, A.; Fens, T.W.; Herder, P.M.

    2014-01-01

    Smart home energy systems are technically possible to realize but are not yet applied on a large scale partly due to the fact that no common standards exist that enable interconnection of components that make up these smart energy systems. Multiple standards have been developed which are competing

  1. A Review of Decision Support Systems for Smart Homes in the Health Care System.

    Science.gov (United States)

    Baumgärtel, Diana; Mielke, Corinna; Haux, Reinhold

    2018-01-01

    The use of decision support systems for smart homes can provide attractive solutions for challenges that have arisen in the Health Care System due to ageing of society. In order to provide an overview of current research projects in this field, a systematic literature review was performed according to the PRISMA approach. The aims of this work are to provide an overview of current research projects and to update a similar study from 2012. The literature search engines IEEE Xplore and PubMed were used. 23 papers were included. Most of the systems presented are developed for monitoring the patient regardless of their illness. For decision support, mainly rule-based approaches are used.

  2. A new infusion pathway monitoring system utilizing electrostatic induced potential.

    Science.gov (United States)

    Maki, Hiromichi; Yonezawa, Yoshiharu; Ogawa, Hidekuni; Ninomiya, Ishio; Sada, Kouji; Hamada, Shingo; Hahn, Alien W; Caldwell, W Morton

    2006-01-01

    We have developed a new infusion pathway monitoring system employing linear integrated circuits and a low-power 8-bit single chip microcomputer. The system is available for hospital and home use and it constantly monitors the intactness of the pathway. The sensor is an electro-conductive polymer electrode wrapped around the infusion polyvinyl chloride infusion tube. This records an AC (alternating current) voltage induced on the patient's body by electrostatic coupling from the normal 100 volt, 60 Hz AC power line wiring field in the patient's room. If the injection needle or infusion tube becomes detached, then the system detects changes in the induced AC voltage and alerts the nursing station, via the nurse call system or PHS (personal handy phone System).

  3. Decision support at home (DS@HOMEsystem architectures and requirements

    Directory of Open Access Journals (Sweden)

    Marschollek Michael

    2012-05-01

    Full Text Available Abstract Background Demographic change with its consequences of an aging society and an increase in the demand for care in the home environment has triggered intensive research activities in sensor devices and smart home technologies. While many advanced technologies are already available, there is still a lack of decision support systems (DSS for the interpretation of data generated in home environments. The aim of the research for this paper is to present the state-of-the-art in DSS for these data, to define characteristic properties of such systems, and to define the requirements for successful home care DSS implementations. Methods A literature review was performed along with the analysis of cross-references. Characteristic properties are proposed and requirements are derived from the available body of literature. Results 79 papers were identified and analyzed, of which 20 describe implementations of decision components. Most authors mention server-based decision support components, but only few papers provide details about the system architecture or the knowledge base. A list of requirements derived from the analysis is presented. Among the primary drawbacks of current systems are the missing integration of DSS in current health information system architectures including interfaces, the missing agreement among developers with regard to the formalization and customization of medical knowledge and a lack of intelligent algorithms to interpret data from multiple sources including clinical application systems. Conclusions Future research needs to address these issues in order to provide useful information – and not only large amounts of data – for both the patient and the caregiver. Furthermore, there is a need for outcome studies allowing for identifying successful implementation concepts.

  4. Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology

    Science.gov (United States)

    Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen

    2017-01-01

    This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents’ wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident’s feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment. PMID:28714884

  5. Design and Implementation of a Smart Home System Using Multisensor Data Fusion Technology.

    Science.gov (United States)

    Hsu, Yu-Liang; Chou, Po-Huan; Chang, Hsing-Cheng; Lin, Shyan-Lung; Yang, Shih-Chin; Su, Heng-Yi; Chang, Chih-Chien; Cheng, Yuan-Sheng; Kuo, Yu-Chen

    2017-07-15

    This paper aims to develop a multisensor data fusion technology-based smart home system by integrating wearable intelligent technology, artificial intelligence, and sensor fusion technology. We have developed the following three systems to create an intelligent smart home environment: (1) a wearable motion sensing device to be placed on residents' wrists and its corresponding 3D gesture recognition algorithm to implement a convenient automated household appliance control system; (2) a wearable motion sensing device mounted on a resident's feet and its indoor positioning algorithm to realize an effective indoor pedestrian navigation system for smart energy management; (3) a multisensor circuit module and an intelligent fire detection and alarm algorithm to realize a home safety and fire detection system. In addition, an intelligent monitoring interface is developed to provide in real-time information about the smart home system, such as environmental temperatures, CO concentrations, communicative environmental alarms, household appliance status, human motion signals, and the results of gesture recognition and indoor positioning. Furthermore, an experimental testbed for validating the effectiveness and feasibility of the smart home system was built and verified experimentally. The results showed that the 3D gesture recognition algorithm could achieve recognition rates for automated household appliance control of 92.0%, 94.8%, 95.3%, and 87.7% by the 2-fold cross-validation, 5-fold cross-validation, 10-fold cross-validation, and leave-one-subject-out cross-validation strategies. For indoor positioning and smart energy management, the distance accuracy and positioning accuracy were around 0.22% and 3.36% of the total traveled distance in the indoor environment. For home safety and fire detection, the classification rate achieved 98.81% accuracy for determining the conditions of the indoor living environment.

  6. An integrated healthcare system for personalized chronic disease care in home-hospital environments.

    Science.gov (United States)

    Jeong, Sangjin; Youn, Chan-Hyun; Shim, Eun Bo; Kim, Moonjung; Cho, Young Min; Peng, Limei

    2012-07-01

    Facing the increasing demands and challenges in the area of chronic disease care, various studies on the healthcare system which can, whenever and wherever, extract and process patient data have been conducted. Chronic diseases are the long-term diseases and require the processes of the real-time monitoring, multidimensional quantitative analysis, and the classification of patients' diagnostic information. A healthcare system for chronic diseases is characterized as an at-hospital and at-home service according to a targeted environment. Both services basically aim to provide patients with accurate diagnoses of disease by monitoring a variety of physical states with a number of monitoring methods, but there are differences between home and hospital environments, and the different characteristics should be considered in order to provide more accurate diagnoses for patients, especially, patients having chronic diseases. In this paper, we propose a patient status classification method for effectively identifying and classifying chronic diseases and show the validity of the proposed method. Furthermore, we present a new healthcare system architecture that integrates the at-home and at-hospital environment and discuss the applicability of the architecture using practical target services.

  7. A system for intelligent home care ECG upload and priorisation.

    Science.gov (United States)

    D'Angelo, Lorenzo T; Tarita, Eugeniu; Zywietz, Tosja K; Lueth, Tim C

    2010-01-01

    In this contribution, a system for internet based, automated home care ECG upload and priorisation is presented for the first time. It unifies the advantages of existing telemonitoring ECG systems adding functionalities such as automated priorisation and usability for home care. Chronic cardiac diseases are a big group in the geriatric field. Most of them can be easily diagnosed with help of an electrocardiogram. A frequent or long-term ECG analysis allows early diagnosis of e.g. a cardiac infarction. Nevertheless, patients often aren't willing to visit a doctor for prophylactic purposes. Possible solutions of this problem are home care devices, which are used to investigate patients at home without the presence of a doctor on site. As the diffusion of such systems leads to a huge amount of data which has to be managed and evaluated, the presented approach focuses on an easy to use software for ECG upload from home, a web based management application and an algorithm for ECG preanalysis and priorisation.

  8. A videoconferencing tool acting as a home-based healthcare monitoring robot for elderly patients.

    Science.gov (United States)

    Mapundu, Zamikhaya; Simonnet, Thierry; van der Walt, J S

    2012-01-01

    Currently, healthcare costs associated with aging at home can be prohibitive if individuals require continual/periodical supervision and assistance because of Alzheimer's disease. Open-source tools and videoconferencing tools are attracting more significant organizations; it has been observed that another way to reduce medical care costs is to reduce the length of the patient's hospitalization and reinforce home sanitary support by medical professionals with family care givers. Videoconferencing has been around for a while and presently this technology is the leading way in reducing healthcare costs, thus making medical care more available and convenient for both doctors and patients. This article portrays how the videoconferencing tool can be utilized to improve communication practices for patient monitoring using a Robot Companion. SWOT analysis method is also presented in a form of a summary and was utilized to evaluate the user's point of view.

  9. The perceptions of cognitively impaired patients and their caregivers of a home telecare system

    Directory of Open Access Journals (Sweden)

    Mehrabian S

    2014-12-01

    Full Text Available Shima Mehrabian,1 Jocelyne Extra,2 Ya-Huei Wu,2 Maribel Pino,2 Latchezar Traykov,1 Anne-Sophie Rigaud2 1Department of Neurology, University Hospital (UH “Alexandrovska”, Sofia, Bulgaria; 2Department of Gerontology, Hôpital Broca, Assitance Publique-Hôpitaux de Paris, EA 4468, Faculte de Médecine, Université Paris Descartes, Paris, France Abstract: Assistive and telecare technologies have been developed to support older adults with cognitive impairments, as well as their caregivers, from their homes. The way potential users perceive telecare and smart home systems plays a key role in their acceptance of this new technology. We evaluate the acceptance of home telecare technologies among patients suffering from cognitive impairment and their caregivers. Prototypes of telecare devices were developed to demonstrate their features and capabilities and to train patients, families, and health care professionals in their use. We conducted semistructured interviews to elicit the perceptions of 30 patients with mild cognitive impairment, 32 patients with Alzheimer’s disease, and 30 caregivers, regarding the risks and advantages of home telecare and smart houses. Survey results reflected participants' largely positive reactions to these technologies. Regarding home telecare, the cognitive stimulation program earned the highest proportion of positive responses, followed by the devices' care of emergencies. The participants generally agreed that home telecare and smart houses could significantly improve their quality of life. However, some technical and ethical concerns, such as the way of provision, installation, and monitoring of the systems, were reported to be in need of addressing before implementation of this system. Keywords: home telecare, Alzheimer’s disease, mild cognitive impairment, caregiver, cognitive stimulation

  10. An In-home Advanced Robotic System to Manage Elderly Home-care Patients' Medications: A Pilot Safety and Usability Study.

    Science.gov (United States)

    Rantanen, Pekka; Parkkari, Timo; Leikola, Saija; Airaksinen, Marja; Lyles, Alan

    2017-05-01

    We examined the safety profile and usability of an integrated advanced robotic device and telecare system to promote medication adherence for elderly home-care patients. There were two phases. Phase I aimed to verify under controlled conditions in a single nursing home (n = 17 patients) that no robotic malfunctions would hinder the device's safe use. Phase II involved home-care patients from 3 sites (n = 27) who were on long-term medication. On-time dispensing and missed doses were recorded by the robotic system. Patients' and nurses' experiences were assessed with structured interviews. The 17 nursing home patients had 457 total days using the device (Phase I; mean, 26.9 per patient). On-time sachet retrieval occurred with 97.7% of the alerts, and no medication doses were missed. At baseline, Phase II home-dwelling patients reported difficulty remembering to take their medicines (23%), and 18% missed at least 2 doses per week. Most Phase II patients (78%) lived alone. The device delivered and patients retrieved medicine sachets for 99% of the alerts. All patients and 96% of nurses reported the device was easy to use. This trial demonstrated the safety profile and usability of an in-home advanced robotic device and telecare system and its acceptability to patients and nurses. It supports individualized patient dosing schedules, patient-provider communications, and on-time, in-home medication delivery to promote adherence. Real time dose-by-dose monitoring and communication with providers if a dose is missed provide oversight generally not seen in home care. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  11. Home

    Science.gov (United States)

    AF Branding & Trademark Licensing Join the Air Force Home About Us The Air Force Symbol Display Resources Document Library TM Connect Search AF Branding and Trademark Licensing Program: important links Legal Documents 10 U.S.C. § 2260 15 U.S.C. § 167;167; 1114-1125 DODI 5535.12, DoD Branding and

  12. Home

    Science.gov (United States)

    intersect as Attack Wing leaders change roles The 112th COS postured as cyber shield for Pa. infrastructure 111th Attack Wing 111th Attack Wing 21st Century Guard Airmen Home News Photos Art Video Resources - The Balance Search 111th Attack Wing: COMMUNITY/ENVIRO May 16, 2018; Pa. Department of Health update

  13. A tele-home care system exploiting the DVB-T technology and MHP.

    Science.gov (United States)

    Angius, G; Pani, D; Raffo, L; Randaccio, P; Seruis, S

    2008-01-01

    The aim of this research work is the development of a low-cost system for telemedicine based on the DVB-T technology. The diffusion of DVB-T standard and the low cost of DVB-T set-top boxes bring the vision of a capillary distribution of tele-home care monitoring systems with easy-to-use patient's interface. Exploiting the potentiality of the DVB-T set-top box, we transformed it into an "on-demand tele-home care interface". The Xlet we developed is able to govern the functionality of an external microcontroller-based unit for the acquisition of the bio-signals of interest. The uplink connection is used to send the exam results to a remote care center. The Xlet providing the patient interface on the set-top box is uploaded by a DVB-T broadcaster without any intervention in the patient's home. A prototypal low-cost base station for the acquisition of the patient's signals (1-lead ECG) has been developed. It is able to be connected to the set-top box via an infrared link. A smart-card-based system is in charge for the customization of the Xlet for every patient. The proposed system, based on a currently widespread infrastructure, is able to allow the patients monitoring from home without any installation procedure. Even untrained (or elderly) people can easily use such system due to their practice with the basic DVB-T home-entertainment equipments.

  14. Analysis of commode grab bar usage for the monitoring of older adults in the smart home environment.

    Science.gov (United States)

    Arcelus, Amaya; Holtzman, Megan; Goubran, Rafik; Sveistrup, Heidi; Guitard, Paulette; Knoefel, Frank

    2009-01-01

    The occurrence of falls inside the home is a common yet potentially hazardous issue for adults as they age. Even with the installation of physical aids such as grab bars, weight transfers on and off a toilet or bathtub can become increasingly difficult as a person's level of physical mobility and sense of balance deteriorate. Detecting this deterioration becomes an important goal in fall prevention within a smart home. This paper develops an unobtrusive method of analyzing the usage of toilet grab bars using pressure sensors embedded into the arm rests of a commode. Clinical parameters are successfully extracted automatically from a series of stand-to-sit (StSi) and sit-to-stand (SiSt) transfers performed by a trial group of young and older adults. A preliminary comparison of the parameters indicates differences between the two groups, and aligns well with published characteristics obtained using accelerometers worn on the body. The unobtrusive nature of this method provides a useful tool to be incorporated into a system of continuous monitoring of older adults within the smart home environment.

  15. Warfarin monitoring in nursing homes assessed by case histories. Do recommendations and electronic alerts affect judgements?

    Science.gov (United States)

    Teruel, Reyes Serrano; Thue, Geir; Fylkesnes, Svein Ivar; Sandberg, Sverre; Kristoffersen, Ann Helen

    2017-09-01

    Older adults treated with warfarin are prone to complications, and high-quality monitoring is essential. The aim of this case history based study was to assess the quality of warfarin monitoring in a routine situation, and in a situation with an antibiotic-warfarin interaction, before and after receiving an electronic alert. In April 2014, a national web-based survey with two case histories was distributed among Norwegian nursing home physicians and general practitioners working part-time in nursing homes. Case A represented a patient on stable warfarin treatment, but with a substantial INR increase within the therapeutic interval. Case B represented a more challenging patient with trimethoprim sulfamethoxazole (TMS) treatment due to pyelonephritis. In both cases, the physicians were asked to state the next warfarin dose and the INR recall interval. In case B, the physicians could change their suggestions after receiving an electronic alert on the TMS-warfarin interaction. Three hundred and ninety eight physicians in 292 nursing homes responded. Suggested INR recall intervals and warfarin doses varied substantially in both cases. In case A, 61% gave acceptable answers according to published recommendations, while only 9% did so for case B. Regarding the TMS-warfarin interaction in case history B, the electronic alert increased the percentage of respondents correctly suggesting a dose reduction from 29% to 53%. Having an INR instrument in the nursing home was associated with shortened INR recall times. Practical advice on handling of warfarin treatment and drug interactions is needed. Electronic alerts as presented in electronic medical records seem insufficient to change practice. Availability of INR instruments may be important regarding recall time.

  16. Building heating technology in Smart Home using PI System management tools

    OpenAIRE

    Vanus, Jan; Vojcinak, Petr; Martinek, Radek; Kelnar, Michal; Machacek, Zdenek; Bilik, Petr; Koziorek, Jiri; Zidek, Jan

    2016-01-01

    For comfortable remote monitoring of some operational and technical functions inside own Smart Home building, it is possible to use a lot of useful programmes and tools. However, not each programme or tool is suited to this purpose, or it does not offer required functionality. The aim of this paper is to describe using an appropriate software tool of PI System for a real-time monitoring of acquired data from real technology parts located at a training centre of the Moravian-Silesian Wood Clus...

  17. Data monitoring system of technical diagnosis system for EAST

    International Nuclear Information System (INIS)

    Qian Jing; Weng Peide; Chen Zhuomin; Wu Yu; Xi Weibin; Luo Jiarong

    2010-01-01

    Technical diagnosis system (TDS) is an important subsystem to monitor status parameters of EAST (experimental advanced superconducting tokamak). The upgraded TDS data monitoring system is comprised of management floor, monitoring floor and field floor.. Security protection, malfunction record and analysis are designed to make the system stable, robust and friendly. During the past EAST campaigns, the data monitoring system has been operated reliably and stably. The signal conditioning system and software architecture are described. (authors)

  18. Environmental monitoring system with TLD

    International Nuclear Information System (INIS)

    Aguerre, L.; Carelli, J.; Gregori, B.

    2006-01-01

    Presently work the methodology used by the Laboratory of Thermoluminescent Dosimetry (TLD) of the Nuclear Regulatory Authority (RNA) to gauge it system of environmental monitoring in function of the media absorbed dose rate in free air and the environmental dose equivalent, H * (10), according to the recommendation ICRU Report 47 is described. It was studied the response of the environmental dosemeter (DA) in fields of photonic radiation of energies W60, Wl 10, W200 and 137 Cs. The irradiations were carried out following the recommendations of the standard ISO:4037. It was analyzed the response in the DA of the detectors LiF: Mg, Ti and CaF 2 : Dy for the different radiation qualities and the relative response at 137 Cs of both. The methodology used in the evaluation of the dose includes: the correction of the readings of both detectors by fading, gotten experimentally, the witness of transfers, the energy answer and the value of the zero. The dose is calculated applying the average pondered in uncertainty of the dose obtained for each type of detector. Its were analyzed and calculated the uncertainties that affect to the measurement following the recommendation of the Argentine standard IRAM 35050. The detection limit of the absorbed dose rate in free air of this system it is 3.5 n Gy/h for a period of sampling of 3 months. With this detection limit environmental dose equivalent rates of the order of 70 n Sv/h are measured with an expanded uncertainty of the order of 10% with a cover factor k = 2. (Author)

  19. Integrated Monitoring System of Production Processes

    Directory of Open Access Journals (Sweden)

    Oborski Przemysław

    2016-12-01

    Full Text Available Integrated monitoring system for discrete manufacturing processes is presented in the paper. The multilayer hardware and software reference model was developed. Original research are an answer for industry needs of the integration of information flow in production process. Reference model corresponds with proposed data model based on multilayer data tree allowing to describe orders, products, processes and save monitoring data. Elaborated models were implemented in the integrated monitoring system demonstrator developed in the project. It was built on the base of multiagent technology to assure high flexibility and openness on applying intelligent algorithms for data processing. Currently on the base of achieved experience an application integrated monitoring system for real production system is developed. In the article the main problems of monitoring integration are presented, including specificity of discrete production, data processing and future application of Cyber-Physical-Systems. Development of manufacturing systems is based more and more on taking an advantage of applying intelligent solutions into machine and production process control and monitoring. Connection of technical systems, machine tools and manufacturing processes monitoring with advanced information processing seems to be one of the most important areas of near future development. It will play important role in efficient operation and competitiveness of the whole production system. It is also important area of applying in the future Cyber-Physical-Systems that can radically improve functionally of monitoring systems and reduce the cost of its implementation.

  20. Distributed Monitoring System Based on ICINGA

    CERN Multimedia

    Haen, C; Neufeld, N

    2011-01-01

    The LHCb online system relies on a large and heterogeneous I.T. infrastructure : it comprises more than 2000 servers and embedded systems and more than 200 network devices. While for the control and monitoring of detectors, PLCs, and readout boards an industry standard SCADA system PVSSII has been put in production, we use a low level monitoring system to monitor the control infrastructure itself. While our previous system was based on a single central NAGIOS server, our current system uses a distributed ICINGA infrastructure.

  1. PEM fuel cell monitoring system

    Science.gov (United States)

    Meltser, Mark Alexander; Grot, Stephen Andreas

    1998-01-01

    Method and apparatus for monitoring the performance of H.sub.2 --O.sub.2 PEM fuel cells. Outputs from a cell/stack voltage monitor and a cathode exhaust gas H.sub.2 sensor are corrected for stack operating conditions, and then compared to predetermined levels of acceptability. If certain unacceptable conditions coexist, an operator is alerted and/or corrective measures are automatically undertaken.

  2. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo

    1993-03-01

    Japan Atomic Energy Research Institute (JAERI) has continued the radiation background survey and environmental radiation monitoring to ensure the safety of the residents around the Institute. For the monitoring of β and γ radiations and α and β radioactivities in air, the centralized automatic environmental radiation monitoring system (EMS) applying a computer with monitoring stations (MS) was established. The system has been renewed twice in 1973 and 1988. In 1962, a new concept emergency environmental γ-ray monitoring system (MP) was begun to construct and completed in 1965 independent of EMS. The first renewal of the EMS was carried out by focusing on the rapid and synthetic judgement and estimation of the environmental impacts caused by radiation and radioactive materials due to the operation of nuclear facilities by centralizing the data measured at MS, MP, a meteorological station, stack monitors and drainage monitoring stations under the control of computer. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop caused by thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min. monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles. (J.P.N.)

  3. Remote Microphone System Use at Home: Impact on Caregiver Talk

    Science.gov (United States)

    Benítez-Barrera, Carlos R.; Angley, Gina P.; Tharpe, Anne Marie

    2018-01-01

    Purpose: The purpose of this study was to investigate the effects of home use of a remote microphone system (RMS) on the spoken language production of caregivers with young children who have hearing loss. Method: Language Environment Analysis recorders were used with 10 families during 2 consecutive weekends (RMS weekend and No-RMS weekend). The…

  4. Web-based home rehabilitation gaming system for balance training

    Directory of Open Access Journals (Sweden)

    Oleh Kachmar

    2014-06-01

    Full Text Available Currently, most systems for virtual rehabilitation and motor training require quite complex and expensive hardware and can be used only in clinical settings. Now, a low-cost rehabilitation game training system has been developed for patients with movement disorders; it is suitable for home use under the distant supervision of a therapist. It consists of a patient-side application installed on a home computer and the virtual rehabilitation Game Server in the Internet. System can work with different input gaming devices connected through USB or Bluetooth, such as a Nintendo Wii balance board, a Nintendo Wii remote, a MS Kinect sensor, and custom made rehabilitation gaming devices based on a joystick. The same games can be used with all training devices. Assessment of the Home Rehabilitation Gaming System for balance training was performed on six patients with Cerebral Palsy, who went through daily training sessions for two weeks. Preliminary results showed balance improvement in patients with Cerebral Palsy after they had completed home training courses. Further studies are needed to establish medical requirements and evidence length.

  5. An IBeacon-Based Location System for Smart Home Control.

    Science.gov (United States)

    Liu, Qinghe; Yang, Xinshuang; Deng, Lizhen

    2018-06-11

    Indoor location and intelligent control system can bring convenience to people’s daily life. In this paper, an indoor control system is designed to achieve equipment remote control by using low-energy Bluetooth (BLE) beacon and Internet of Things (IoT) technology. The proposed system consists of five parts: web server, home gateway, smart terminal, smartphone app and BLE beacons. In the web server, fingerprint matching based on RSSI stochastic characteristic and posture recognition model based on geomagnetic sensing are used to establish a more efficient equipment control system, combined with Pedestrian Dead Reckoning (PDR) technology to improve the accuracy of location. A personalized menu of remote “one-click” control is finally offered to users in a smartphone app. This smart home control system has been implemented by hardware, and precision and stability tests have been conducted, which proved the practicability and good user experience of this solution.

  6. Critical function monitoring system algorithm development

    International Nuclear Information System (INIS)

    Harmon, D.L.

    1984-01-01

    Accurate critical function status information is a key to operator decision-making during events threatening nuclear power plant safety. The Critical Function Monitoring System provides continuous critical function status monitoring by use of algorithms which mathematically represent the processes by which an operating staff would determine critical function status. This paper discusses in detail the systematic design methodology employed to develop adequate Critical Function Monitoring System algorithms

  7. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-06-02

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  8. Apparatus, System, And Method For Roadway Monitoring

    KAUST Repository

    Claudel, Christian G.

    2015-01-01

    An apparatus, system, and method for monitoring traffic and roadway water conditions. Traffic flow and roadway flooding is monitored concurrently through a wireless sensor network. The apparatus and system comprises ultrasound rangefinders monitoring traffic flow, flood water conditions, or both. Routing information may be calculated from the traffic conditions, such that routes are calculated to avoid roadways that are impassable or are slow due to traffic conditions.

  9. Home blood pressure monitoring, secure electronic messaging and medication intensification for improving hypertension control: a mediation analysis.

    Science.gov (United States)

    Ralston, J D; Cook, A J; Anderson, M L; Catz, S L; Fishman, P A; Carlson, J; Johnson, R; Green, B B

    2014-01-01

    We evaluated the role of home monitoring, communication with pharmacists, medication intensification, medication adherence and lifestyle factors in contributing to the effectiveness of an intervention to improve blood pressure control in patients with uncontrolled essential hypertension. We performed a mediation analysis of a published randomized trial based on the Chronic Care Model delivered over a secure patient website from June 2005 to December 2007. Study arms analyzed included usual care with a home blood pressure monitor and usual care with home blood pressure monitor and web-based pharmacist care. Mediator measures included secure messaging and telephone encounters; home blood pressure monitoring; medications intensification and adherence and lifestyle factors. Overall fidelity to the Chronic Care Model was assessed with the Patient Assessment of Chronic Care (PACIC) instrument. The primary outcome was percent of participants with blood pressure (BP) <140/90 mm Hg. At 12 months follow-up, patients in the web-based pharmacist care group were more likely to have BP <140/90 mm Hg (55%) compared to patients in the group with home blood pressure monitors only (37%) (p = 0.001). Home blood pressure monitoring accounted for 30.3% of the intervention effect, secure electronic messaging accounted for 96%, and medication intensification for 29.3%. Medication adherence and self-report of fruit and vegetable intake and weight change were not different between the two study groups. The PACIC score accounted for 22.0 % of the main intervention effect. The effect of web-based pharmacist care on improved blood pressure control was explained in part through a combination of home blood pressure monitoring, secure messaging, and antihypertensive medication intensification.

  10. [Clinical utility of home blood pressure monitoring in patients under treatment].

    Science.gov (United States)

    Bauk, L; Costa, H A; Caligiuri, S I

    2015-01-01

    A low number of patients who are treated with antihypertensive drugs achieve therapeutic goals. Home blood pressure monitoring is an excellent tool for studying this population. To determine the prevalence of patients with controlled and uncontrolled hypertension, as well as white-coat-effect and masked hypertension, and to evaluate the relationship with target organ damage in different groups. Blood pressure readings were performed simultaneously in the clinic and in the home using the same validated oscillometric equipment on 83 hypertensive patients on treatment with 2 or more antihypertensive drugs. They were then classified into 4 groups according to the cut-off values of the clinic and home blood pressure measurements. Left ventricular mass index, carotid intima media thickness, and microalbuminuria as markers of target organ damage, were also evaluated. Controlled blood pressure was present in 32.5%, 30.2% had sustained hypertension. The white coat effect was seen in 26.5%, while 10.8% were masked uncontrolled hypertension. Left ventricular mass index was higher in patients with no ambulatory control compared to controlled patients, and carotid IMT was also higher too in uncontrolled and white coat effect groups than controlled patients. More than one third of our patients who were treated with 2 or more drugs were not properly controlled, and they had significantly greater target organ damage than controlled patients. Copyright © 2014 SEHLELHA. Published by Elsevier Espana. All rights reserved.

  11. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  12. Monitoring of heavy metal concentrations in home outdoor air using moss bags

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, Marcela, E-mail: arivera@creal.ca [Centre for Research in Environmental Epidemiology CREAL, Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Barcelona (Spain); Universitat Pompeu Fabra, Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP) (Spain); Zechmeister, Harald [University of Vienna, Faculty of Life Sciences, Vienna (Austria); Medina-Ramon, Mercedes; Basagana, Xavier [Centre for Research in Environmental Epidemiology CREAL, Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP) (Spain); Foraster, Maria [Centre for Research in Environmental Epidemiology CREAL, Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Barcelona (Spain); Universitat Pompeu Fabra, Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP) (Spain); Bouso, Laura [Centre for Research in Environmental Epidemiology CREAL, Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP) (Spain); Moreno, Teresa [Institute of Environmental Assessment and Water Research (IDAEA-CSIC), Barcelona (Spain); Solanas, Pascual; Ramos, Rafael [Research Unit, Family Medicine, Girona, Jordi Gol Institute for Primary Care Research (IDIAP Jordi Gol), Catalan Institute of Health, Catalunya (Spain); Department of Medical Sciences, School of Medicine, University of Girona (Spain); Koellensperger, Gunda [University of Natural Resources and Applied Life Sciences, Vienna (Austria); Deltell, Alexandre [Polytechnic School, GREFEMA, University of Girona (Spain); Vizcaya, David [Centre for Research in Environmental Epidemiology CREAL, Barcelona (Spain); Municipal Institute of Medical Research (IMIM-Hospital del Mar), Barcelona (Spain); Universitat Pompeu Fabra, Barcelona (Spain); CIBER Epidemiologia y Salud Publica (CIBERESP) (Spain)

    2011-04-15

    One monitoring station is insufficient to characterize the high spatial variation of traffic-related heavy metals within cities. We tested moss bags (Hylocomium splendens), deployed in a dense network, for the monitoring of metals in outdoor air and characterized metals' long-term spatial distribution and its determinants in Girona, Spain. Mosses were exposed outside 23 homes for two months; NO{sub 2} was monitored for comparison. Metals were not highly correlated with NO{sub 2} and showed higher spatial variation than NO{sub 2}. Regression models explained 61-85% of Cu, Cr, Mo, Pb, Sb, Sn, and Zn and 72% of NO{sub 2} variability. Metals were strongly associated with the number of bus lines in the nearest street. Heavy metals are an alternative traffic-marker to NO{sub 2} given their toxicological relevance, stronger association with local traffic and higher spatial variability. Monitoring heavy metals with mosses is appealing, particularly for long-term exposure assessment, as mosses can remain on site many months without maintenance. - Research highlights: > Moss bags can be used to measure the metal's long-term spatial distribution within cities. > Heavy metals in mosses are not highly correlated with ambient NO{sub 2} concentrations. > Heavy metals show higher spatial variation and association with traffic than NO{sub 2}. > Bus lines in the nearest street explain 75-85% of Mo, Cr, Sb, Sn and Cu variability. > Moss bags are useful for long-term at home exposure assessment in epidemiological studies. - The long-term spatial distribution of heavy metals, measured with moss bags, is mainly determined by proximity to bus lines.

  13. Monitoring of heavy metal concentrations in home outdoor air using moss bags

    International Nuclear Information System (INIS)

    Rivera, Marcela; Zechmeister, Harald; Medina-Ramon, Mercedes; Basagana, Xavier; Foraster, Maria; Bouso, Laura; Moreno, Teresa; Solanas, Pascual; Ramos, Rafael; Koellensperger, Gunda; Deltell, Alexandre; Vizcaya, David

    2011-01-01

    One monitoring station is insufficient to characterize the high spatial variation of traffic-related heavy metals within cities. We tested moss bags (Hylocomium splendens), deployed in a dense network, for the monitoring of metals in outdoor air and characterized metals' long-term spatial distribution and its determinants in Girona, Spain. Mosses were exposed outside 23 homes for two months; NO 2 was monitored for comparison. Metals were not highly correlated with NO 2 and showed higher spatial variation than NO 2 . Regression models explained 61-85% of Cu, Cr, Mo, Pb, Sb, Sn, and Zn and 72% of NO 2 variability. Metals were strongly associated with the number of bus lines in the nearest street. Heavy metals are an alternative traffic-marker to NO 2 given their toxicological relevance, stronger association with local traffic and higher spatial variability. Monitoring heavy metals with mosses is appealing, particularly for long-term exposure assessment, as mosses can remain on site many months without maintenance. - Research highlights: → Moss bags can be used to measure the metal's long-term spatial distribution within cities. → Heavy metals in mosses are not highly correlated with ambient NO 2 concentrations. → Heavy metals show higher spatial variation and association with traffic than NO 2 . → Bus lines in the nearest street explain 75-85% of Mo, Cr, Sb, Sn and Cu variability. → Moss bags are useful for long-term at home exposure assessment in epidemiological studies. - The long-term spatial distribution of heavy metals, measured with moss bags, is mainly determined by proximity to bus lines.

  14. The design of radiation monitor passageway system

    International Nuclear Information System (INIS)

    Chu Chengsheng

    2006-10-01

    The Radiation Monitor Passageway System is designed as four modules, the radiation detection modules, the control modules, the mechanism modules and the optional modules. this system integrate the radiation detection technology and door ban control technology. It is a effective radiation monitor equipment with high detect sensitiveness, it will be hopeful devoted to national nuclear safeguard. (authors)

  15. Internet of Things Framework for Home Care Systems

    Directory of Open Access Journals (Sweden)

    Biljana Risteska Stojkoska

    2017-01-01

    Full Text Available The increasing average age of the population in most industrialized countries imposes a necessity for developing advanced and practical services using state-of-the-art technologies, dedicated to personal living spaces. In this paper, we introduce a hierarchical distributed approach for home care systems based on a new paradigm known as Internet of Things (IoT. The proposed generic framework is supported by a three-level data management model composed of dew computing, fog computing, and cloud computing for efficient data flow in IoT based home care systems. We examine the proposed model through a real case scenario of an early fire detection system using a distributed fuzzy logic approach. The obtained results prove that such implementation of dew and fog computing provides high accuracy in fire detection IoT systems, while achieving minimum data latency.

  16. Centralized environmental radiation monitoring system in JAERI

    International Nuclear Information System (INIS)

    Katagiri, H.; Kobalyashi, H.

    1993-01-01

    JAERI has continued the environmental radiation background survey and monitoring to ensure the safety of the peoples around the institute since one year before the first criticality of JRR-1 (Japan Research Reactor No.1) in August 1957. Air absorbed doses from β and γ radiation, α and β radioactivity in air and the radioactivities in environmental samples were the monitoring items. For the monitoring of β and γ radiation and α and β radioactivity in air, monitoring station and the centralized automatic environmental radiation monitoring system applying a computer were established as a new challenging monitoring system for nuclear facility, which was the first one not only in Japan but also in the would in 1960 and since then the system has been renewed two times (in 1973 and 1988) by introducing the latest technology in the fields of radiation detection and computer control at each stage. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop arisen from thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles

  17. Storage monitoring systems for the year 2000

    International Nuclear Information System (INIS)

    Nilsen, C.; Pollock, R.

    1997-01-01

    In September 1993, President Clinton stated the US would ensure that its fissile material meet the highest standards of safety, security, and international accountability. Frequent human inspection of the material could be used to ensure these standards. However, it may be more effective and less expensive to replace these manual inspections with virtual inspections via remote monitoring technologies. To prepare for this future, Sandia National Laboratories has developed several monitoring systems, including the Modular Integrated Monitoring System (MIMS) and Project Straight-Line. The purpose of this paper is to describe a Sandia effort that merges remote monitoring technologies into a comprehensive storage monitoring system that will meet the near-term as well as the long-term requirements for these types of systems. Topics discussed include: motivations for storage monitoring systems to include remote monitoring; an overview of the needs and challenges of providing a storage monitoring system for the year 2000; an overview of how the MIMS and Straight-Line can be enhanced so that together they create an integrated and synergistic information system by the end of 1997; and suggested milestones for 1998 and 1999 to assure steady progress in preparing for the needs of 2000

  18. Security And Privacy Issues in Healthcare Monitoring Systems: A Case Study

    DEFF Research Database (Denmark)

    Handler, Daniel Tolboe; Hauge, Lotte; Spognardi, Angelo

    2017-01-01

    Security and privacy issues are rarely taken into account in automated systems for monitoring elderly people in their home, exposing inhabitants to a number of threats they are usually not aware of. As a case study to expose the major vulnerabilities these systems are exposed to, this paper reviews...... a generic example of automated healthcare monitoring system. The security and privacy issues identified in this case study can be easily generalised and regarded as alarm bells for all the pervasive healthcare professionals....

  19. Pilot study for home monitoring of cough capacity in amyotrophic lateral sclerosis: A case series.

    Science.gov (United States)

    Paneroni, M; Trainini, D; Winck, J C; Vitacca, M

    2014-01-01

    Cough capacity derangement is associated with a high risk of pulmonary complications in amyotrophic lateral sclerosis patients when cough assistance is not routinely performed at home. The primary aim of this study was to evaluate the feasibility of a long-term home based daily self-monitoring cough capacity. Eighteen subjects were enrolled in a 9-month study at home. Changes in peak cough expiratory flow, oxygen saturation, respiratory discomfort and incidence of respiratory deterioration events were evaluated. In subjects presenting respiratory deterioration events, decline in the abovementioned respiratory variables was evaluated (#NCT00613899). During an average follow-up of 125±102 days, a total of 1175 measures were performed on 12 subjects. Mean compliance to proposed evaluations was 37±32% which worsened over time. Peak cough expiratory flow decreased by 15.08±32.43L/min monthly. Five subjects reported 6 episodes of respiratory deterioration events, after a mean period of 136±108 days. They had poor respiratory function and more years of disease. There was no difference in peak cough expiratory flow and its decline whether subjects presented respiratory deterioration events or not. In 4 subjects the respiratory discomfort score significantly worsened after respiratory deterioration events from 3.0±1.41 to 4.25±1.71. Daily self-monitoring of peak cough expiratory flow, oxygen saturation and respiratory discomfort seems difficult to obtain because of poor adherence to measures; this protocol does not seem to add anything to current practice of advising on clinical derangements. Confirmatory larger studies are necessary. Copyright © 2013 Sociedade Portuguesa de Pneumologia. Published by Elsevier España. All rights reserved.

  20. Supervisory monitoring system in nuclear power plants

    International Nuclear Information System (INIS)

    Ciftcioglu, O.; Turkcan, E.

    1997-01-01

    Monitoring of a power plant is one of the essential tasks during operation and the computer-based implementations are nowadays seemingly quite mature. However, presently these are still not satisfactory enough to meet the high standards to the licensing requirements and they are mostly not truly integrated to the plant's design-based monitoring system. This is basically due to the robustness problem as the majority of the methods are not robust enough for the monitoring of the safety parameter set in a plant or intelligent supervision. Therefore, a supervisory monitoring system (SMS) in a plant is necessary to supervise the monitoring tasks: determining the objectives to be obtained and finding the means to support them. SMS deals with the changing plant status and the coordination of the information flow among the monitoring subunits. By means of these robustness and consistency in monitoring is achieved. The paper will give the guidelines of knowledge and data management techniques in a framework of robust comprehensive and coordinated monitoring which is presented as supervisory monitoring. Such a high level monitoring serves for consistent and immediate actions in fault situations while this particularly has vital importance in preventing imminent severe accidents next to the issues of recognition of the monitoring procedures for licensing and enhanced plant safety. (author). 8 refs, 5 figs

  1. The CERN GSM monitoring system

    International Nuclear Information System (INIS)

    Ghabrous, Carlos

    2010-01-01

    This paper presents the way CERN has approached the problem of monitoring its own GSM infrastructure, especially in the Large Hadron Collider (LHC) accelerator tunnel and other underground facilities, where a leaky feeder cable carries mobile phone signals, and where this technology is the only means for inter-personnel communications.

  2. A low cost, adaptive mixed reality system for home-based stroke rehabilitation.

    Science.gov (United States)

    Chen, Yinpeng; Baran, Michael; Sundaram, Hari; Rikakis, Thanassis

    2011-01-01

    This paper presents a novel, low-cost, real-time adaptive multimedia environment for home-based upper extremity rehabilitation of stroke survivors. The primary goal of this system is to provide an interactive tool with which the stroke survivor can sustain gains achieved within the clinical phase of therapy and increase the opportunity for functional recovery. This home-based mediated system has low cost sensing, off the shelf components for the auditory and visual feedback, and remote monitoring capability. The system is designed to continue active learning by reducing dependency on real-time feedback and focusing on summary feedback after a single task and sequences of tasks. To increase system effectiveness through customization, we use data from the training strategy developed by the therapist at the clinic for each stroke survivor to drive automated system adaptation at the home. The adaptation includes changing training focus, selecting proper feedback coupling both in real-time and in summary, and constructing appropriate dialogues with the stroke survivor to promote more efficient use of the system. This system also allows the therapist to review participant's progress and adjust the training strategy weekly.

  3. Beam monitoring system for intense neutron source

    International Nuclear Information System (INIS)

    Tron, A.M.

    2001-01-01

    Monitoring system realizing novel principle of operation and allowing to register a two-dimensional beam current distribution within entire aperture (100...200 mm) of ion pipe for a time in nanosecond range has been designed and accomplished for beam control of the INR intense neutron source, for preventing thermo-mechanical damage of its first wall. Key unit of the system is monitor of two-dimensional beam current distribution, elements of which are high resistant to heating by the beam and to radiation off the source. The description of the system and monitor are presented. Implementation of the system for the future sources with more high intensities are discussed. (author)

  4. Upgrade of the LHCb ECAL monitoring system

    CERN Document Server

    Guz, Yu

    2015-01-01

    The LHCb ECAL is a shashlik calorimeter of 6016 cells, covering 7.68 x 6.24 m$^2$ area. To monitor the readout chain of each ECAL cell, the LHCb ECAL is equipped with a LED based monitoring system. During the LHC Run I (2009-2012) it was found that the precision of the monitoring suffers from the radiation degradation of transparency of polystyrene clear fibers used to transport the LED light to the ECAL photomultipliers. In order to improve the performance of the monitoring system, and especially in view of significant increase of LHCb working luminosity foreseen after 2018, the present plastic fibers have been replaced by radiation hard quartzfi bers. The performance of the old LHCb ECAL monitoring system during LHC Run I and the design of the upgraded system are discussed here.

  5. Monitoring system in reactor dry well

    International Nuclear Information System (INIS)

    Horie, Akira; Suzuki, Shun-ichi; Yamamoto, Shinji; Kubokawa, Toshihiko; Takagi, Sakae; Yokosawa, Makoto.

    1991-01-01

    A failed portion of a dry well in a BWR type reactor is monitored and identified from a remote place by a simple structure. That is, laser beams are irradiated under scanning to a portion to be monitored. Then, the reflection light is monitored by a light receiving and monitoring system, and abnormalities such as defects or leaks of monitored portion are optically detected by a remote viewing equipment. With such a constitution, the portion to be monitored in poor operation circumstances of the reactor dry well can always be monitored efficiently from a remote place. The device of the present invention does not undergo the effect of radiation noises, etc. and it is excellent in heat resistance and radiation resistance. (I.S.)

  6. Introducing a feedback training system for guided home rehabilitation

    Directory of Open Access Journals (Sweden)

    Disselhorst-Klug Catherine

    2010-01-01

    Full Text Available Abstract As the number of people requiring orthopaedic intervention is growing, individualized physiotherapeutic rehabilitation and adequate postoperative care becomes increasingly relevant. The chances of improvement in the patients condition is directly related to the performance and consistency of the physiotherapeutic exercises. In this paper a smart, cost-effective and easy to use Feedback Training System for home rehabilitation based on standard resistive elements is introduced. This ensures high accuracy of the exercises performed and offers guidance and control to the patient by offering direct feedback about the performance of the movements. 46 patients were recruited and performed standard physiotherapeutic training to evaluate the system. The results show a significant increase in the patient's ability to reproduce even simple physiotherapeutic exercises when being supported by the Feedback Training System. Thus physiotherapeutic training can be extended into the home environment whilst ensuring a high quality of training.

  7. Introducing a feedback training system for guided home rehabilitation.

    Science.gov (United States)

    Kohler, Fabian; Schmitz-Rode, Thomas; Disselhorst-Klug, Catherine

    2010-01-15

    As the number of people requiring orthopaedic intervention is growing, individualized physiotherapeutic rehabilitation and adequate postoperative care becomes increasingly relevant. The chances of improvement in the patients condition is directly related to the performance and consistency of the physiotherapeutic exercises.In this paper a smart, cost-effective and easy to use Feedback Training System for home rehabilitation based on standard resistive elements is introduced. This ensures high accuracy of the exercises performed and offers guidance and control to the patient by offering direct feedback about the performance of the movements.46 patients were recruited and performed standard physiotherapeutic training to evaluate the system. The results show a significant increase in the patient's ability to reproduce even simple physiotherapeutic exercises when being supported by the Feedback Training System. Thus physiotherapeutic training can be extended into the home environment whilst ensuring a high quality of training.

  8. The VICKSI monitor interlock system

    International Nuclear Information System (INIS)

    Borchardt, D.; Kluppak, B.

    1983-01-01

    Dose rate equivalents are monitored separately for all working areas and evaluated by a central unit. The accelerator is shut off automatically if the maximum permissible concentrations given in the Radiation Protection Ordinance are exceeded and if persons are endangered. However, the experimenter may, on his own responsibility, define certain areas as 'vacated' (no staff members inside). Operation can then proceed as desired. Entry of persons into these areas is checked by the central computer. (orig./HP) [de

  9. An Extensible Software Infrastructure for Computer Aided Custom Monitoring of Patients in Smart Homes

    OpenAIRE

    Ritwik Dutta; Marilyn Wolf

    2015-01-01

    This paper describes the tradeoffs and the design from scratch of a self-contained, easy-to-use health dashboard software system that provides customizable data tracking for patients in smart homes. The system is made up of different software modules and comprises a front-end and a back-end component. Built with HTML, CSS, and JavaScript, the front-end allows adding users, logging into the system, selecting metrics, and specifying health goals. The backend consists of a N...

  10. EDGAR, a new plant radiation monitoring system

    International Nuclear Information System (INIS)

    Vuong, Q.M.; Da Costa Vieira, D.

    2004-01-01

    The EDGAR system is a new radiation monitoring system for nuclear power plant, reprocessing plant and nuclear research reactor for radioactive contamination, gamma and neutron field monitoring. Developed by French Atomic Energy Agency, this system provides not only complete functions of standard RMS, also allows spectroscopy level detection of alpha and beta particles based on a patented collimator unit. A complete computerized approach has been taken allowing full installation control in a single PC based display and communication unit. (author)

  11. Optimising corrosion monitoring in district heating systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Thorarinsdottir, R.I.; Andersen, A.

    2002-01-01

    A three-year project - financially supported by the Nordic Industrial Fund - on monitoring of corrosion in district heating systems has been initiated with participation of researchers and industrial partners in Denmark, Finland, Iceland, Norway and Sweden. The primary objective of the project...... is to improve the quality control in district heating systems by corrosion monitoring. In Danish systems electrochemical impedance spectroscopy (EIS), linear polarisation resistance (LPR), high-sensitive electrical resistance (ER) technology, crevice corrosion probes, as well as weight loss coupons...

  12. Appliance based control for Home Power Management Systems

    International Nuclear Information System (INIS)

    Özkan, Hanife Apaydın

    2016-01-01

    This study scrutinizes energy-friendly smart home appliances (hereafter ‘smart appliances’), control of these appliances and their effects on the efficient use of energy. To accomplish this, smart appliances and their operation principles are introduced and their energy savings compared to conventional appliances are analyzed using precise measurements. Then, a real-time Appliance-based Home Power Management System (Ab-HPMS) which manages power consumption of smart appliances and that of the house as a whole is proposed. For Ab-HPMS, an appliance control algorithm, called Appliance-based Rolling Wave Planning (Ab-RWP), is developed with the aim of reducing electricity cost and improving energy efficiency while maintaining user comfort. Ab-RWP algorithm interacts with appliances in a priority order based on user comfort which is determined by utilizing their smart operational characteristics. Operations of smart appliances and their integrations with Ab-HPMS are modeled with Petri nets to verify that they meet the requirements expressed in the specifications. Simulation results demonstrate that proposed Ab-HPMS provides improvements in terms of the energy consumption reduction of about 5%–16%, cost reduction of about 10%–24% and peak reduction at high demand period of about 38%–53% compared to conventional appliances usage. - Highlights: • The effects of smart home appliances on energy saving are investigated. • Petri nets models of smart appliances are developed to simulate their operations in smart home. • A real-time appliance-based home power management system (Ab-HPMS) is proposed. • Power density function is evaluated to interrupt the operation of smart washing machine.

  13. IEEE 802.11 ECG monitoring system.

    Science.gov (United States)

    Tejero-Calado, Juan; Lopez-Casado, Carmen; Bernal-Martin, Antonio; Lopez-Gomez, Miguel; Romero-Romero, Marco; Quesada, Guillermo; Lorca, Julio; Rivas, Ramon

    2005-01-01

    New wireless technologies make possible the implementation of high level integration wireless devices which allow the replacement of traditional large wired monitoring devices. This kind of devices favours at-home hospitalization, reducing the affluence to sanitary assistance centers to make routine controls. This fact causes a really favourable social impact, especially for elder people, rural-zone inhabitant, chronic patients and handicapped people. Furthermore, it offers new functionalities to physicians and will reduce the sanitary cost. Among these functionalities, biomedical signals can be sent to other devices (screen, PDA, PC...) or processing centers, without restricting the patients' mobility. The aim of this project is the development and implementation of a reduced size multi-channel electrocardiograph based on IEEE 802.11, which allows wireless monitoring of patients, and the insertion of the information into the TCP/IP Hospital network.

  14. Accuracy of home versus ambulatory blood pressure monitoring in the diagnosis of white-coat and masked hypertension.

    Science.gov (United States)

    Kang, Yuan-Yuan; Li, Yan; Huang, Qi-Fang; Song, Jie; Shan, Xiao-Li; Dou, Yu; Xu, Xin-Juan; Chen, Shou-Hong; Wang, Ji-Guang

    2015-08-01

    We investigated accuracy of home blood pressure (BP) monitoring in the diagnosis of white-coat and masked hypertension in comparison with ambulatory BP monitoring. Our study participants were enrolled in the China Ambulatory and Home BP Registry, and underwent clinic, home, and 24-h ambulatory BP measurements. We defined white-coat hypertension as an elevated clinic SBP/DBP (≥140/90 mmHg) and a normal 24-h ambulatory (coat hypertension (13.1 vs. 19.9%), masked hypertension (17.8 vs. 13.1%), and sustained hypertension (46.4 vs. 39.6%) significantly (P ≤ 0.02) differed between 24-h ambulatory and home BP monitoring. In treated patients (n = 1201), only the prevalence of masked hypertension differed significantly (18.7 vs. 14.5%; P = 0.005). Regardless of the treatment status, home compared with 24-h ambulatory BP had low sensitivity (range 47-74%), but high specificity (86-94%), and accordingly low positive (41-87%), but high negative predictive values (80-94%), and had moderate diagnostic agreement (82-85%) and Kappa statistic (0.41-0.66). In untreated and treated patients, age advancing was associated with a higher prevalence of white-coat hypertension and a lower prevalence of masked hypertension defined by 24-h ambulatory (P ≤ 0.03) but not home BP (P ≥ 0.10). Home BP monitoring has high specificity, but low sensitivity in the diagnosis of white-coat and masked hypertension, and may therefore behave as a complementary to, but not a replacement of, ambulatory BP monitoring.

  15. Distributed intelligent urban environment monitoring system

    Science.gov (United States)

    Du, Jinsong; Wang, Wei; Gao, Jie; Cong, Rigang

    2018-02-01

    The current environmental pollution and destruction have developed into a world-wide major social problem that threatens human survival and development. Environmental monitoring is the prerequisite and basis of environmental governance, but overall, the current environmental monitoring system is facing a series of problems. Based on the electrochemical sensor, this paper designs a small, low-cost, easy to layout urban environmental quality monitoring terminal, and multi-terminal constitutes a distributed network. The system has been small-scale demonstration applications and has confirmed that the system is suitable for large-scale promotion

  16. Computer-controlled radiation monitoring system

    International Nuclear Information System (INIS)

    Homann, S.G.

    1994-01-01

    A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable

  17. Ulysses spacecraft control and monitoring system

    Science.gov (United States)

    Hamer, P. A.; Snowden, P. J.

    1991-01-01

    The baseline Ulysses spacecraft control and monitoring system (SCMS) concepts and the converted SCMS, residing on a DEC/VAX 8350 hardware, are considered. The main functions of the system include monitoring and displaying spacecraft telemetry, preparing spacecraft commands, producing hard copies of experimental data, and archiving spacecraft telemetry. The SCMS system comprises over 20 subsystems ranging from low-level utility routines to the major monitoring and control software. These in total consist of approximately 55,000 lines of FORTRAN source code and 100 VMS command files. The SCMS major software facilities are described, including database files, telemetry processing, telecommanding, archiving of data, and display of telemetry.

  18. RFID and IOT for Attendance Monitoring System

    Directory of Open Access Journals (Sweden)

    Dedy Irawan Joseph

    2018-01-01

    Full Text Available In recent years, RFID technology has been widely used in various sectors, such as in-education, transportation, agriculture, animal husbandry, store sales and other sectors. RFID utilization in education is student attendance monitoring system, by using Internet of Things (IoT and Cloud technology, it will produce a real time attendance monitoring system that can be accessed by various parties, such as lecturer, campus administration and parents. With this monitoring system if there are students who are not present can be immediately discovered and can be taken immediate action and the learning process can run smoothly.

  19. Home Automation System Based on Intelligent Transducer Enablers

    Science.gov (United States)

    Suárez-Albela, Manuel; Fraga-Lamas, Paula; Fernández-Caramés, Tiago M.; Dapena, Adriana; González-López, Miguel

    2016-01-01

    This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers), which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet. PMID:27690031

  20. Home Automation System Based on Intelligent Transducer Enablers.

    Science.gov (United States)

    Suárez-Albela, Manuel; Fraga-Lamas, Paula; Fernández-Caramés, Tiago M; Dapena, Adriana; González-López, Miguel

    2016-09-28

    This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers), which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet.

  1. Home Automation System Based on Intelligent Transducer Enablers

    Directory of Open Access Journals (Sweden)

    Manuel Suárez-Albela

    2016-09-01

    Full Text Available This paper presents a novel home automation system named HASITE (Home Automation System based on Intelligent Transducer Enablers, which has been specifically designed to identify and configure transducers easily and quickly. These features are especially useful in situations where many transducers are deployed, since their setup becomes a cumbersome task that consumes a significant amount of time and human resources. HASITE simplifies the deployment of a home automation system by using wireless networks and both self-configuration and self-registration protocols. Thanks to the application of these three elements, HASITE is able to add new transducers by just powering them up. According to the tests performed in different realistic scenarios, a transducer is ready to be used in less than 13 s. Moreover, all HASITE functionalities can be accessed through an API, which also allows for the integration of third-party systems. As an example, an Android application based on the API is presented. Remote users can use it to interact with transducers by just using a regular smartphone or a tablet.

  2. Remote supervision of GIS monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Pannunzio, J.; Juge, P.; Ficheux, A.; Rayon, J.L. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada)

    2007-07-01

    Operators of gas-insulated substations (GIS) are increasingly concerned with failure prevention, scheduled maintenance, personnel safety and shortage of maintenance crews. Until recently, the density levels of the insulating gas sulfur hexafluoride (SF6) was the only parameter controlled in gas-insulated substations. Modern digital type control and monitoring equipment have been widely used in the past decade. Remote indication of gas density and status of dynamic components was made possible and shown on local control panels. Modern GIS monitoring systems offer features such as SF6 monitoring, SF6 leakage trends, internal arc localization and detection. The required information is recorded in a local computer and displaced onto a local human machine interface (HMI) or a local industrial PC mounted next to the GIS. These monitoring systems are used as decision making tools to facilitate maintenance activities and optimize the management of assets. This paper presented the latest developments in digital monitoring systems in terms of modern digital architecture; management of information flows between monitoring systems and control systems; operation of remote supervision; configuration of high voltage substations and information sharing; and, types of links between GIS room and remote supervision. This paper also demonstrated what can be achieved by moving the central HMI of a GIS monitoring system to the decision-making centres. It was shown that integrated features that allow remote on-line or automated management have reached an acceptable level of reliability and comfort for operators. 5 figs.

  3. Performance Monitoring Applied to System Supervision

    Directory of Open Access Journals (Sweden)

    Bertille Somon

    2017-07-01

    Full Text Available Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL performance problem.

  4. Automated Cryocooler Monitor and Control System Software

    Science.gov (United States)

    Britchcliffe, Michael J.; Conroy, Bruce L.; Anderson, Paul E.; Wilson, Ahmad

    2011-01-01

    This software is used in an automated cryogenic control system developed to monitor and control the operation of small-scale cryocoolers. The system was designed to automate the cryogenically cooled low-noise amplifier system described in "Automated Cryocooler Monitor and Control System" (NPO-47246), NASA Tech Briefs, Vol. 35, No. 5 (May 2011), page 7a. The software contains algorithms necessary to convert non-linear output voltages from the cryogenic diode-type thermometers and vacuum pressure and helium pressure sensors, to temperature and pressure units. The control function algorithms use the monitor data to control the cooler power, vacuum solenoid, vacuum pump, and electrical warm-up heaters. The control algorithms are based on a rule-based system that activates the required device based on the operating mode. The external interface is Web-based. It acts as a Web server, providing pages for monitor, control, and configuration. No client software from the external user is required.

  5. Communications interface for plant monitoring system

    International Nuclear Information System (INIS)

    Lee, K.L.; Morgan, F.A.

    1988-01-01

    This paper presents the communications interface for an intelligent color graphic system which PSE and G developed as part of a plant monitoring system. The intelligent graphic system is designed to off-load traditional host functions such as dynamic graphic updates, keyboard handling and alarm display. The distributed system's data and synchronization problems and their solutions are discussed

  6. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  7. Dream Home: a multiview stereoscopic interior design system

    Science.gov (United States)

    Hsiao, Fu-Jen; Teng, Chih-Jen; Lin, Chung-Wei; Luo, An-Chun; Yang, Jinn-Cherng

    2010-01-01

    In this paper, a novel multi-view stereoscopic interior design system, "Dream Home", has been developed to bring users new interior design experience. Different than other interior design system before, we put emphasis on its intuitive manipulation and multi-view stereoscopic visualization in real time. Users can do their own interior design just using their hands and eyes without any difficulty. They manipulate furniture cards directly as they wish to setup their living room in the model house task space, get the multi-view 3D visual feedback instantly, and re-adjust cards until they are satisfied. No special skills are required, and you can explore your design talent arbitrarily. We hope that "Dream Home" will make interior design more user-friendly, more intuitive, and more vivid.

  8. EMBEDDED SYSTEMS FOR VIBRATION MONITORING

    Directory of Open Access Journals (Sweden)

    Miloš Milovančević

    2014-08-01

    Full Text Available The purpose of the research presented in this paper is the development of the optimal micro configuration for vibration monitoring of pumping aggregate, based on Microchip’s microcontroller (MC. Hardware used is 10-bit MC, upgraded with 12/bit A/D converter. Software for acquisition and data analysis is optimized for testing turbo pumps with rotation speed up to 2000 rpm. This software limitation is set for automatic diagnostics and for individual and manual vibro-diagnostic; the only limitation is set by accelerometer performance. The authors have performed numerous measurements on a wide range of turbo aggregates for establishing the operational condition of pumping aggregates.

  9. Examining the work-home interface: an ecological systems perspective

    OpenAIRE

    MacKinnon, Richard A,

    2012-01-01

    This dissertation outlines a mixed-methods investigation of work-life balance, examining the construct from an ecological systems theory perspective. This necessitated research at the individual, group, organisational and wider societal levels and included three studies: two using quantitative methodology and one using qualitative.\\ud The quantitative phase included two studies that examined the experience of the home-work interface from the perspective of the employee, examining the impact o...

  10. Monitoring of ovarian activity by measurement of urinary excretion rates of estrone glucuronide and pregnanediol glucuronide using the Ovarian Monitor, Part II: reliability of home testing.

    Science.gov (United States)

    Blackwell, Leonard F; Vigil, Pilar; Gross, Barbara; d'Arcangues, Catherine; Cooke, Delwyn G; Brown, James B

    2012-02-01

    The UNDP/WHO/World Bank/Special Programme of Research, Development and Research Training in Human Reproduction (Geneva) set up a study to determine whether it is feasible for women to monitor their ovarian activity reliably by home testing. Daily self-monitoring of urinary hormone metabolites for menstrual cycle assessment was evaluated by comparison of results obtained with the Home Ovarian Monitor by untrained users both at home and in study centres. Women collected daily data for urinary estrone glucuronide (E1G) and pregnanediol glucuronide (PdG) for two cycles, then the procedure was repeated in the women's local centre (in Chile, Australia or New Zealand) giving a total of 113 duplicate cycles. The tests were performed without the benefit of replicates or quality controls. The home and centre cycles were normalized and compared to identify assay errors, and the resulting home and centre menstrual cycle profiles were averaged. Reliable mean cycle profiles were obtained with the home and centre excretion rates agreeing to within 36 ± 21 nmol/24 h for E1G and 0.77 ± 0.28 µmol/24 h for baseline PdG values (1-5 µmol/24 h). The cycles had a mean length of 28.1 ± 3.1 days (n = 112; 5th and 95th percentiles: 24 and 35 days, respectively), a mean follicular phase of 14.8 ± 3.1 days (n = 107; 5th and 95th percentiles: 11 and 21 days) and a mean luteal phase length of 13.3 ± 1.5 days (n = 106; 5th and 95th percentiles: 11 and 17 days), calculated from the day of the LH peak. The study confirmed that the Ovarian Monitor pre-coated assay tubes worked well even in the hands of lay users, without standard curves, quality controls or replicates. Point-of-care monitoring to give reliable fertility data is feasible.

  11. Unobtrusive Wireless Monitoring System for Assisted Living and Improving the Wellbeing of Elderly People

    International Nuclear Information System (INIS)

    Browne, Aidan; Duncliffe, Richard; Spillane, James; Walsh, Colin; Hill, Martin; O'Mahony, Tom; O'Reilly, Fergus

    2011-01-01

    A novel system to unobtrusively monitor the wellbeing of elderly people based on their activity patterns is presented. The system uses a wireless ZigBee network to monitor the electrical usage in a subject's home and then sends this data to an Apache server via HTTP from a GPRS unit. The data is logged in a MySQL database where pattern analysis is used to identify periods of significant inactivity. When such an event is identified designated contacts are notified by text message. For subjects requiring higher levels of monitoring a portable health monitor can be integrated incorporating a fall detector and panic button to inform of emergency situations.

  12. A qualitative case study of telehealth for in-home monitoring to support the management of type 2 diabetes.

    Science.gov (United States)

    Carlisle, Karen; Warren, Robin

    2013-10-01

    The present study formed part of a randomised controlled trial of telehealth for in-home monitoring to support people with poorly controlled type 2 diabetes. We explored the experiences of patients and healthcare practitioners, and their perceptions of the telehealth model of care used in the trial. In addition to their usual diabetes care, participants receive diabetes care from a diabetes educator nurse via an in-home broadband communication device. On average, each patient participated in 14 videoconferences with a diabetes care coordinator during the 12-month trial period. Qualitative data was collected from two general practices and included semi-structured interviews and document review of patient clinical notes. A total of 12 people were interviewed: 8 health practitioners and 4 patients. Patients and health practitioners expressed a high level of satisfaction with the model of care provided. Patients also reported positive health and social outcomes as a result of being involved in the trial and indicated that in the main they had achieved their goals and were happy with their progress over the 12-month period. Analysis of interviews revealed three broad elements associated with the implementation of telehealth: interpersonal factors, operational problems and the wider health system context within which the general practices and trial team were operating. The findings suggest that adopting telehealth in the management of type 2 diabetes can lead to improved diabetes control, but more support is required to ensure sustainability and widespread implementation.

  13. Wearable Health Monitoring Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  14. Radiation monitoring system based on EPICS

    International Nuclear Information System (INIS)

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2008-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)

  15. Deployable Thermoelectric Metamaterial Energy Harvesting Monitoring System

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will combine a novel asynchronous monitoring system with the first-of-its-kind thermoelectric metamaterial.  The thermoelectric prototype is constructed...

  16. Wearable Health Monitoring Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this proposal is to demonstrate the feasibility of producing a wearable health monitoring system for the human body that is functional, comfortable,...

  17. Geographic information system planning and monitoring best ...

    African Journals Online (AJOL)

    Poor urbanization policies, inefficient planning and monitoring technologies are evident. The consequences include some of the worst types of environmental hazards. Best urbanization practices require integrated planning approaches that result in environmental conservation. Geographic Information systems (GIS) provide ...

  18. Monitoring System for ALICE Surface Areas

    CERN Document Server

    Demirbasci, Oguz

    2016-01-01

    I have been at CERN for 12 weeks within the scope of Summer Student Programme working on a monitoring system project for surface areas of the ALICE experiment during this period of time. The development and implementation of a monitoring system for environmental parameters in the accessible areas where a cheap hardware setup can be deployed were aim of this project. This report explains how it was developed by using Arduino, Raspberry PI, WinCC OA and DIM protocol.

  19. ZPR-9 airborne plutonium monitoring system

    International Nuclear Information System (INIS)

    Rusch, G.K.; McDowell, W.P.; Knapp, W.G.

    1975-01-01

    An airborne plutonium monitoring system which is installed in the ZPR-9 (Zero Power Reactor No. 9) facility at Argonne National Laboratory is described. The design and operational experience are discussed. This monitoring system utilizes particle size and density discrimination, alpha particle energy discrimination, and a background-subtraction techique operating in cascade to separate airborne-plutonium activity from other, naturally occurring, airborne activity. Relatively high sensitivity and reliability are achieved

  20. 75 FR 81138 - Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2011...

    Science.gov (United States)

    2010-12-27

    ... [CMS-1510-CN2] RIN 0938-AP88 Medicare Program; Home Health Prospective Payment System Rate Update for... ``Medicare Program; Home Health Prospective Payment System Rate Update for Calendar Year 2011; Changes in... Prospective Payment System Rate Update for Calendar Year 2011; Changes in Certification Requirements for Home...

  1. Home blood-pressure monitoring in a hypertensive pregnant population: cost minimisation study.

    Science.gov (United States)

    Xydopoulos, G; Perry, H; Sheehan, E; Thilaganathan, B; Fordham, R; Khalil, A

    2018-03-08

    Traditional monitoring of blood pressure in hypertensive pregnant women requires frequent visits to the maternity outpatient services. Home blood-pressure monitoring (HBPM) could offer a cost-saving alternative that is acceptable to patients. The main objective of this study was to undertake a health economic analysis of HBPM compared with traditional monitoring in hypertensive pregnant women. This was a case-control study. Cases were pregnant women with hypertension who had HBPM with or without the adjunct of a smartphone app, via a specially designed pathway. The control group were managed as per existing hospital guidelines. Specific outcome measures were the number of outpatient visits, inpatient bed stays and investigations performed. Maternal, fetal and neonatal adverse outcomes were also recorded. Health economic analysis was performed using two methods: direct cost comparison of the study dataset and process scenario modelling. There were 108 women in the HBPM group, of whom 29 recorded their results on the smartphone app (App-HBPM) and 79 in their notes (Non-app HBPM). The control group comprised of 58 patients. There were significantly more women with chronic hypertension in the HBPM group (49.1% vs 25.9%, P = 0.004). The HBPM group had significantly longer duration of monitoring (9 weeks vs 5 weeks P = 0.004) and started monitoring from an earlier gestation (30 weeks vs 33.6 weeks, P = 0.001). Despite these differences, the mean saving per week for HBPM compared with the control group was £200.69. For the App-HBPM cohort, the saving per week compared with the control group was £286.53. The process modelling method predicted savings of between £98.32 and £245.80 per week using HBPM compared to the traditional monitoring. HBPM in hypertensive pregnancies appears to be cost-saving compared with traditional monitoring, without compromising maternal, fetal or neonatal safety. Larger studies are required to confirm these findings. This article is

  2. Data monitoring system for PV solar generators

    International Nuclear Information System (INIS)

    Stoev, M.; Katerski, A.; Williams, A.

    2000-01-01

    The two 1.5 kWp photovoltaic (PV) solar generators are installed and the new PC data monitoring system is developed by applying EC standards for European Solar Test Installation (ESTI). The schematic system diagram of PV generator is presented. The recording parameters for analytical and global monitoring are discussed. The meteorological data from ESTI sensors, temperature sensor and electrical data from inverter and calibrated shunt are stored via analog digital converters (ADC) on a hard disk of data storage PC. Data Logger and Monitor software for automatic data acquisition, treatment and visual distance control of all output PV data from PV solar generator has been created

  3. BABY MONITORING SYSTEM USING WIRELESS SENSOR NETWORKS

    Directory of Open Access Journals (Sweden)

    G. Rajesh

    2014-09-01

    Full Text Available Sudden Infant Death Syndrome (SIDS is marked by the sudden death of an infant during sleep that is not predicted by the medical history and remains unexplained even after thorough forensic autopsy and detailed death investigation. In this we developed a system that provides solutions for the above problems by making the crib smart using the wireless sensor networks (WSN and smart phones. The system provides visual monitoring service through live video, alert services by crib fencing and awakens alert, monitoring services by temperature reading and light intensity reading, vaccine reminder and weight monitoring.

  4. Financing of Solar Home Systems (SHS); Finanzierung von Solar Home Systemen. Erfahrungen aus der Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Adelmann, P.; Rimpler, G.; Zimmermann, A. [Phocos AG, Ulm (Germany)

    2005-07-01

    In many cases Solar Systems are the cheapest option for rural electrification. Often the users spend every month a quite high amount of money for dry cell batteries, kerosene and candles to supply a radio or to have light. Problem is that the users can spend a certain amount every month, but they are not able to have the necessary investment for a SHS at one. Financing would be requires. There are different ways to finance the solar home systems. In some cases the user has to pay a fee for the service. In these cases the investor is the owner of the system. In other cases a microcredit is given to the user. His then the owner of the system and responsible for any losses in the system. An interesting model is a battery charging station. In this model it is possible for the user to become step by step owner of a solar system. Conclusion. Fee for service systems did not perform perfectly. Main reason is the missing responsibility of the user for any damage. Microcredits did perform well in several places in Asia. A interesting option for the future are battery charging stations. This model hashighest flexibility in financing. It can be adopted at any moment to the abilities of the user. (orig.)

  5. Survey of the home sewage disposal systems in northeast Ohio.

    Science.gov (United States)

    Tumeo, Mark A; Newland, Juliet

    2009-09-01

    This article reports on failure rates in onsite sewage treatment systems (STS) that were found as part of a comprehensive seven-county survey that was performed under the auspices of the Northeast Ohio Areawide Coordinating Agency (NOACA) during the summer of 2000. The goal was to determine the percentage of onsite, individual home wastewater systems that were "failing." A system was identified as "failing" if, upon inspection, it had observable surfacing of effluent from the treatment system. A certified soil scientist conducted each on-site investigation to ensure consistency in methodology and to provide verification of soil types for each installation. The survey revealed that between 12.7% and 19.7% of the onsite wastewater treatment systems are allowing wastewater to surface as opposed to infiltrate (at the 95% confidence interval). The rate of failure does not vary significantly between aerobic and septic systems or between systems with or without filters.

  6. Comparative effects of valsartan plus either cilnidipine or hydrochlorothiazide on home morning blood pressure surge evaluated by information and communication technology-based nocturnal home blood pressure monitoring.

    Science.gov (United States)

    Fujiwara, Takeshi; Tomitani, Naoko; Kanegae, Hiroshi; Kario, Kazuomi

    2018-01-01

    The authors tested the hypothesis that a valsartan/cilnidipine combination would suppress the home morning blood pressure (BP) surge (HMBPS) more effectively than a valsartan/hydrochlorothiazide combination in patients with morning hypertension, defined as systolic BP (SBP) ≥135 mm Hg or diastolic BP ≥85 mm Hg assessed by a self-measuring information and communication technology-based home BP monitoring device more than three times before either combination's administration. This was an 8-week prospective, multicenter, randomized, open-label clinical trial. The HMBPS, which is a new index, was defined as the mean morning SBP minus the mean nocturnal SBP, both measured on the same day. The authors randomly allocated 129 patients to the valsartan/cilnidipine (63 patients; mean 68.4 years) or valsartan/hydrochlorothiazide (66 patients; mean 67.3 years) combination groups, and the baseline HMBPS values were 17.4 mm Hg vs 16.9 mm Hg, respectively (P = .820). At the end of the treatment period, the changes in nocturnal SBP and morning SBP from baseline were significant in both the valsartan/cilnidipine and valsartan/hydrochlorothiazide groups (P information and communication technology-based home BP monitoring device may become an alternative to ambulatory BP monitoring, which has been a gold standard to measure nocturnal BP and the morning BP surge. ©2018 Wiley Periodicals, Inc.

  7. Moisture monitoring and control system engineering study

    International Nuclear Information System (INIS)

    Carpenter, K.E.; Fadeff, J.G.

    1995-01-01

    During the past 50 years, a wide variety of chemical compounds have been placed in the 149 single-shell tanks (SSTS) on the Hanford Site. A concern relating to chemical stability, chemical control, and safe storage of the waste is the potential for propagating reactions as a result of ferrocyanide-oxidizer and organic-oxidizer concentrations in the SSTS. Propagating reactions in fuel-nitrate mixtures are precluded if the amounts of fuel and moisture present in the waste are within specified limits. Because most credible ignition sources occur near the waste surface, the main emphasis of this study is toward monitoring and controlling moisture in the top 14 cm (5.5 in.) of waste. The purpose of this engineering study is to recommend a moisture monitoring and control system for use in SSTs containing sludge and saltcake. This study includes recommendations for: (1) monitoring and controlling moisture in SSTs; (2) the fundamental design criteria for a moisture monitoring and control system; and (3) criteria for the deployment of a moisture monitoring and control system in hanford Site SSTs. To support system recommendations, technical bases for selecting and using a moisture monitoring and control system are presented. Key functional requirements and a conceptual design are included to enhance system development and establish design criteria

  8. Location estimation in a smart home: system implementation and evaluation using experimental data.

    Science.gov (United States)

    Rahal, Youcef; Pigot, Hélène; Mabilleau, Philippe

    2008-01-01

    In the context of a constantly increasing aging population with cognitive deficiencies, insuring the autonomy of the elders at home becomes a priority. The DOMUS laboratory is addressing this issue by conceiving a smart home which can both assist people and preserve their quality of life. Obviously, the ability to monitor properly the occupant's activities and thus provide the pertinent assistance depends highly on location information inside the smart home. This paper proposes a solution to localize the occupant thanks to Bayesian filtering and a set of anonymous sensors disseminated throughout the house. The localization system is designed for a single person inside the house. It could however be used in conjunction with other localization systems in case more people are present. Our solution is functional in real conditions. We conceived an experiment to estimate precisely its accuracy and evaluate its robustness. The experiment consists of a scenario of daily routine meant to maximize the occupant's motion in meaningful activities. It was performed by 14 subjects, one subject at a time. The results are satisfactory: the system's accuracy exceeds 85% and is independent of the occupant's profile. The system works in real time and behaves well in presence of noise.

  9. Residential Photovoltaic Energy Systems in California: The Effect on Home Sales Prices

    Energy Technology Data Exchange (ETDEWEB)

    Hoen, Ben; Wiser, Ryan; Thayer, Mark; Cappers, Peter

    2012-04-15

    Relatively little research exists estimating the marginal impacts of photovoltaic (PV) energy systems on home sale prices. Using a large dataset of California homes that sold from 2000 through mid-2009, we find strong evidence, despite a variety of robustness checks, that existing homes with PV systems sold for a premium over comparable homes without PV systems, implying a near full return on investment. Premiums for new homes are found to be considerably lower than those for existing homes, implying, potentially, a tradeoff between price and sales velocity. The results have significant implications for homeowners, builders, appraisers, lenders, and policymakers.

  10. Monitor for reactor feedwater systems

    International Nuclear Information System (INIS)

    Takizawa, Yoji; Tomizawa, Teruaki

    1983-01-01

    Purpose: To improve the reliability of operator's procedures upon occurrence of the feedwater system abnormality in a BWR type reactor by presenting the operation with effective information to avoid such abnormality. Constitution: A feedwater temperature at the reactor inlet of a reactor feedwater system measured by a temperature detector and a predetermined value for the feedwater temperature at the reactor inlet determined depending on the reactor conditions are inputted to a start-up system. The start-up system outputs a start-up signal when the difference between the inputted values exceeds a predetermined value. Then, the start-up signal is inputted to a display device where information required for the operator is displayed in the device. Thus, the information required for the operator is rapidly provided upon abnormality of the feedwater system to thereby improve the reliability of the operator's procedures. (Moriyama, K.)

  11. Ambulatory and home blood pressure monitoring: gaps between clinical guidelines and clinical practice in Singapore.

    Science.gov (United States)

    Setia, Sajita; Subramaniam, Kannan; Teo, Boon Wee; Tay, Jam Chin

    2017-01-01

    Out-of-office blood pressure (BP) measurements (home blood pressure monitoring [HBPM] and ambulatory blood pressure monitoring [ABPM]) provide important additional information for effective hypertension detection and management decisions. Therefore, out-of-office BP measurement is now recommended by several international guidelines. This study evaluated the practice and uptake of HBPM and ABPM among physicians from Singapore. A sample of physicians from Singapore was surveyed between 8 September and 5 October 2016. Those included were in public or private practice had been practicing for ≥3 years, directly cared for patients ≥70% of the time, and treated ≥30 patients for hypertension per month. The questionnaire covered six main categories: general BP management, BP variability (BPV) awareness/diagnosis, HBPM, ABPM, BPV management, and associated training needs. Sixty physicians (30 general practitioners, 20 cardiologists, and 10 nephrologists) were included (77% male, 85% aged 31-60 years, and mean 22-year practice). Physicians recommended HBPM and ABPM to 81% and 27% of hypertensive patients, respectively. HBPM was most often used to monitor antihypertensive therapy (88% of physicians) and 97% thought that ABPM was useful for providing information on BPV. HBPM instructions often differed from current guideline recommendations in terms of frequency, number of measurements, and timing. The proportion of consultation time devoted to discussing HBPM and BPV was one-quarter or less for 73% of physicians, and only 55% said that they had the ability to provide education on HBPM and BPV. Patient inertia, poor patient compliance, lack of medical consultation time, and poor patient access to a BP machine were the most common challenges for implementing out-of-office BP monitoring. Although physicians from Singapore do recommend out-of-office BP measurement to patients with hypertension, this survey identified several important gaps in knowledge and clinical practice.

  12. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, T.; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with

  13. RUDO: A Home Ambient Intelligence System for Blind People.

    Science.gov (United States)

    Hudec, Milan; Smutny, Zdenek

    2017-08-22

    The article introduces an ambient intelligence system for blind people which besides providing assistance in home environment also helps with various situations and roles in which blind people may find themselves involved. RUDO, the designed system, comprises several modules that mainly support or ensure recognition of approaching people, alerting to other household members' movement in the flat, work on a computer, supervision of (sighted) children, cooperation of a sighted and a blind person (e.g., when studying), control of heating and zonal regulation by a blind person. It has a unified user interface that gives the blind person access to individual functions. The interface for blind people offers assistance with work on a computer, including writing in Braille on a regular keyboard and specialized work in informatics and electronics (e.g., programming). RUDO can complement the standard aids used by blind people at home, it increases their independence and creates conditions that allow them to become fully involved. RUDO also supports blind people sharing a home with sighted people, which contributes to their feeling of security and greater inclusion in society. RUDO has been implemented in a household for two years, which allows an evaluation of its use in practice.

  14. Monitoring the CMS Data Acquisition System

    CERN Document Server

    Bauer, Gerry; Biery, K; Branson, J; Cano, E; Cheung, H; Ciganek, M; Cittolin, S; Coarasa, J A; Deldicque, C; Dusinberre, E; Erhan, S; Fortes Rodrigues, F; Gigi, D; Glege, F; Gomez-Reino, R; Gutleber, J; Hatton, D; Laurens, J F; Lopez Perez, J A; Meijers, F; Meschi, E; Meyer, A; Mommsen, R; Moser, R; O'Dell, V; Oh, A; Orsini, L B; Patras, V; Paus, C; Petrucci, A; Pieri, M; Racz, A; Sakulin, H; Sani, M; Schieferdecker, P; Schwick, C; Shpakov, D; Simon, S; Sumorok, K; Zanetti, M.

    2010-01-01

    The CMS data acquisition system comprises O(20000) interdependent services that need to be monitored in near real-time. The ability to monitor a large number of distributed applications accurately and effectively is of paramount importance for robust operations. Application monitoring entails the collection of a large number of simple and composed values made available by the software components and hardware devices. A key aspect is that detection of deviations from a specified behaviour is supported in a timely manner, which is a prerequisite in order to take corrective actions efficiently. Given the size and time constraints of the CMS data acquisition system, efficient application monitoring is an interesting research problem. We propose an approach that uses the emerging paradigm of Web-service based eventing systems in combination with hierarchical data collection and load balancing. Scalability and efficiency are achieved by a decentralized architecture, splitting up data collections into regions of col...

  15. Adaptive Home System Using Wireless Sensor Network And Multi Agent System

    OpenAIRE

    Jayarani Kamble; Prof.Nandini Dhole

    2014-01-01

    Smart Home is an emerging technology growing continuously which includes number of new technologies which helps to improve human’s quality of living. This paper proposes an adaptive home system for optimum utilization of power, through Artificial Intelligence and Wireless Sensor network. Artificial Intelligence is a technology for developing adaptive system that can perceive the enviornmrnt, learn from the environment and can make decision using Rule based system.Zigbee is a w...

  16. The SSRL injector beam position monitoring systems

    International Nuclear Information System (INIS)

    Lavender, W.; Baird, S.; Brennan, S.; Borland, M.; Hettel, R.; Nuhn, H.D.; Ortiz, R.; Safranek, J.; Sebek, J.; Wermelskirchen, C.; Yang, J.

    1991-01-01

    The beam position monitoring system of the SSRL injector forms a vital component of its operation. Several different types of instrumentation are used to measure the position or intensity of the electron beam in the injector. These include current toroids, fluorescent screens, Faraday cups, the 'Q' meter, a synchrotron light monitor, and electron beam position monitors. This paper focuses on the use of the electron beam position monitors to measure electron trajectories in the injector transport lines and the booster ring. The design of the beam position monitors is described in another paper to be presented at this conference. There are three different beam position monitor systems in the injector. One system consists of a set of five BPMs located on the injection transport line from the linac to the booster (known as the LTB line). There is a second system of six BPMs located on the ejection transport line (known as the BTS line). Finally, there is an array of 40 BPMs installed on the main booster ring itself. This article describes the software and processing electronics of the systems used to measure electron beam trajectories for the new SSRL injector for SPEAR

  17. A Home Integral Telecare System for HIV/AIDS Patients.

    Science.gov (United States)

    Caceres, Cesar; Gomez, Enrique J; Garcia, Felipe; Chausa, Paloma; Guzman, Jorge; Del Pozo, Francisco; Gatell, Jose Maria

    2005-01-01

    VIHrtual Hospital is a telemedicine web system for improving home integral care of chronic HIV patients through the Internet. Using the videoconference, chat or messaging tools included in the system, patients can visit their healthcare providers (physician, psychologist, nurse, psychiatrist, pharmacist, and social worker), having these access to the Electronic Patient Record. The system also provides a telepharmacy service that controls treatment adherence and side effects, sending the medication to the patient's home by courier. A virtual community has been created, facilitating communication between patients and improving the collaboration between professionals, creating a care plan for each patient. As a complement, there is a virtual library where users can find validated HIV/AIDS information helping to enhance prevention. This system has been developed using low cost technologies in order to extend the number of patients involved in its trial. Thus, VIHrtual Hospital is now on trial in the Hospital Clinic (Barcelona, Spain) involving a hundred patients and twenty healthcare professionals during two years.Although we are still waiting for the final results of the trial, we can already say that the use of telemedicine systems developed ad hoc for a chronic disease, like HIV/AIDS, improve the quality of care of the patients and their care team. The system described is a good example of the possibilities that technologies are offering to create new chronic patient care models based on telemedicine.

  18. Remote monitoring system workshop and technical cooperation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person.

  19. Reliability of operating WWER monitoring systems

    International Nuclear Information System (INIS)

    Yastrebenetsky, M.A.; Goldrin, V.M.; Garagulya, A.V.

    1996-01-01

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs

  20. Monitoring system for OpenPBS environment

    Energy Technology Data Exchange (ETDEWEB)

    Kolosov, V. [ITEP, Moscow (Russian Federation)]. E-mail: victor.kolosov@itep.ru; Lublev, Y. [ITEP, Moscow (Russian Federation); Makarychev, S. [ITEP, Moscow (Russian Federation)

    2004-11-21

    The OpenPBS batch system is widely used in the HEP community. The Open PBS package has a set of tools to check the current status of the system. This information is useful, but it is not sufficient enough for resource accounting and planning. As a solution for this problem, we developed a monitoring system which parses the logfiles from OpenPBS and stores the information into a SQL database (PostgreSQL). This allows us to analyze the data in many different ways using SQL queries. The system was used in ITEP during the last two years for batch farm monitoring.

  1. Remote monitoring system workshop and technical cooperation

    International Nuclear Information System (INIS)

    Kim, Jung Soo; Kwack, E. H.; Yoon, W. K.; Kim, J. S.; Cha, H. Y.; Na, W.W.

    2000-06-01

    RMS workshop at the year focus on installing the material monioring system at technology lab. within TCNC. This system was developed by cooperative monitoring center(CMC) belonging to Sandia national lab. MMS consisted of data storage computer, data collection computer and easily connet to DCM-14 camera using monitoring the NPP by IAEA. The system run when the motion is catching and stroes the event data to MMS server. Also, the system communicate with the internet and then they access to check the event data only if the authencated person

  2. Reliability of operating WWER monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Yastrebenetsky, M A; Goldrin, V M; Garagulya, A V [Ukrainian State Scientific Technical Center of Nuclear and Radiation Safety, Kharkov (Ukraine). Instrumentation and Control Systems Dept.

    1997-12-31

    The elaboration of WWER monitoring systems reliability measures is described in this paper. The evaluation is based on the statistical data about failures what have collected at the Ukrainian operating nuclear power plants (NPP). The main attention is devoted to radiation safety monitoring system and unit information computer system, what collects information from different sensors and system of the unit. Reliability measures were used for decision the problems, connected with life extension of the instruments, and for other purposes. (author). 6 refs, 6 figs.

  3. Medicare and Medicaid Programs; CY 2018 Home Health Prospective Payment System Rate Update and CY 2019 Case-Mix Adjustment Methodology Refinements; Home Health Value-Based Purchasing Model; and Home Health Quality Reporting Requirements. Final rule.

    Science.gov (United States)

    2017-11-07

    This final rule updates the home health prospective payment system (HH PPS) payment rates, including the national, standardized 60-day episode payment rates, the national per-visit rates, and the non-routine medical supply (NRS) conversion factor, effective for home health episodes of care ending on or after January 1, 2018. This rule also: Updates the HH PPS case-mix weights using the most current, complete data available at the time of rulemaking; implements the third year of a 3-year phase-in of a reduction to the national, standardized 60-day episode payment to account for estimated case-mix growth unrelated to increases in patient acuity (that is, nominal case-mix growth) between calendar year (CY) 2012 and CY 2014; and discusses our efforts to monitor the potential impacts of the rebasing adjustments that were implemented in CY 2014 through CY 2017. In addition, this rule finalizes changes to the Home Health Value-Based Purchasing (HHVBP) Model and to the Home Health Quality Reporting Program (HH QRP). We are not finalizing the implementation of the Home Health Groupings Model (HHGM) in this final rule.

  4. An environmental monitoring detection system

    International Nuclear Information System (INIS)

    Leli Yuniarsari; Istofa; Sukandar

    2015-01-01

    Is part of radiation detection of the nuclear facilities engineering activities within nuclear facilities. The system comprised of gamma-ray radiation detector and weather detection which includes anemometer to detect the wind direction and speed, as well as rain gauge to measure the rainfall in a period of time. Data acquisition of the output is processed by Arduino Uno system which transformed the data into a particular standard and then displayed online in the website. The radiation detection system uses gamma-ray detector of NaI(Tl) and GM which convert the radiation detected into electric pulse to be fed into a pre-amp and amplifier and modified into square pulse. The weather detection system on the other hand works based on switch principle. For example, the wind with a certain speed could turn on a switch in the system and produce a voltage or pulse which can be measured. This value will then be interpreted as the wind direction and speed. Likewise for the rainfall gauge, the volume of water entering the bucket will turn the switch on, at the same time producing 1 pulse. The result of the experiment shows that for radiation detection system the output is a square pulse 4 volts by using detector NaI(Tl) and 4.4 volts by using detector GM. For weather detection system, basically was able to detect the wind direction, wind speed and rainfall just to find out further research is needed accuracy and the results compared with the standard tools available in BMKG. (author)

  5. Tritium monitor and collection system

    Science.gov (United States)

    Bourne, G.L.; Meikrantz, D.H.; Ely, W.E.; Tuggle, D.G.; Grafwallner, E.G.; Wickham, K.L.; Maltrud, H.R.; Baker, J.D.

    1992-01-14

    This system measures tritium on-line and collects tritium from a flowing inert gas stream. It separates the tritium from other non-hydrogen isotope contaminating gases, whether radioactive or not. The collecting portion of the system is constructed of various zirconium alloys called getters. These alloys adsorb tritium in any of its forms at one temperature and at a higher temperature release it as a gas. The system consists of four on-line getters and heaters, two ion chamber detectors, two collection getters, and two guard getters. When the incoming gas stream is valved through the on-line getters, 99.9% of it is adsorbed and the remainder continues to the guard getter where traces of tritium not collected earlier are adsorbed. The inert gas stream then exits the system to the decay chamber. Once the on-line getter has collected tritium for a predetermined time, it is valved off and the next on-line getter is valved on. Simultaneously, the first getter is heated and a pure helium purge is employed to carry the tritium from the getter. The tritium loaded gas stream is then routed through an ion chamber which measures the tritium activity. The ion chamber effluent passes through a collection getter that readsorbs the tritium and is removable from the system once it is loaded and is then replaced with a clean getter. Prior to removal of the collection getter, the system switches to a parallel collection getter. The effluent from the collection getter passes through a guard getter to remove traces of tritium prior to exiting the system. The tritium loaded collection getter, once removed, is analyzed by liquid scintillation techniques. The entire sequence is under computer control except for the removal and analysis of the collection getter. 7 figs.

  6. Corrosion Rate Monitoring in District Heating Systems

    DEFF Research Database (Denmark)

    Hilbert, Lisbeth Rischel; Nielsen, Lars Vendelbo; Andersen, A.

    2005-01-01

    be applicable, and if on-line monitoring could improve the quality control. Water quality monitoring was applied as well as corrosion rate monitoring with linear polarization resistance (LPR), electrochemical impedance spectroscopy (EIS), electrical resistance (ER) technique, mass loss and a crevice corrosion......Quality control in district heating systems to keep uniform corrosion rates low and localized corrosion minimal is based on water quality control. Side-stream units equipped with carbon steel probes for online monitoring were mounted in district heating plants to investigate which techniques would...... cell for localized corrosion risk estimation. Important variations in corrosion rate due to changes in make-up water quality were detected with the continuous monitoring provided by ER and crevice cell, while LPR gave unreliable corrosion rates. The acquisition time of two-three days for EIS...

  7. Role of Ambulatory and Home Blood Pressure Monitoring in Clinical Practice: A Narrative Review

    Science.gov (United States)

    Shimbo, Daichi; Abdalla, Marwah; Falzon, Louise; Townsend, Raymond R.; Muntner, Paul

    2015-01-01

    Hypertension, a common cardiovascular disease (CVD) risk factor, is usually diagnosed and treated based on blood pressure readings obtained in the clinic setting. Blood pressure may differ considerably when measured in the clinic versus outside of the clinic setting. Over the past several decades, evidence has accumulated on two approaches for measuring out-of-clinic blood pressure: ambulatory blood pressure monitoring (ABPM) and home blood pressure monitoring (HBPM). Blood pressure measures on ABPM and HBPM each have a stronger association with CVD outcomes than clinic blood pressure. Controversy exists whether ABPM or HBPM is superior for estimating CVD risk, and under what circumstances these methods should be used in clinical practice for assessing out-of-clinic blood pressure. This review describes ABPM and HBPM procedures, the blood pressure phenotypic measures that can be ascertained, and the evidence that supports the use of each approach to measure out-of-clinic blood pressure. This review also describes barriers to the successful implementation of ABPM and HBPM in clinical practice, proposes core competencies for the conduct of these procedures, and highlights important areas for future research. PMID:26457954

  8. Evaluation of a novel canine activity monitor for at-home physical activity analysis.

    Science.gov (United States)

    Yashari, Jonathan M; Duncan, Colleen G; Duerr, Felix M

    2015-07-04

    Accelerometers are motion-sensing devices that have been used to assess physical activity in dogs. However, the lack of a user-friendly, inexpensive accelerometer has hindered the widespread use of this objective outcome measure in veterinary research. Recently, a smartphone-based, affordable activity monitor (Whistle) has become available for measurement of at-home physical activity in dogs. The aim of this research was to evaluate this novel accelerometer. Eleven large breed, privately owned dogs wore a collar fitted with both the Whistle device and a previously validated accelerometer-based activity monitor (Actical) for a 24-h time period. Owners were asked to have their dogs resume normal daily activities. Total activity time obtained from the Whistle device in minutes was compared to the total activity count from the Actical device. Activity intensity from the Whistle device was calculated manually from screenshots of the activity bars displayed in the smartphone-application and compared to the activity count recorded by the Actical in the same 3-min time period. A total of 3740 time points were compared. There was a strong correlation between activity intensity of both devices for individual time points (Pearson's correlation coefficient 0.81, p battery life, the need for manual derivation of activity intensity data and data transfer, and the requirement of Wi-Fi and Bluetooth availability for data transmission.

  9. A qualitative review for wireless health monitoring system

    Science.gov (United States)

    Arshad, Atika; Fadzil Ismail, Ahmad; Khan, Sheroz; Zahirul Alam, A. H. M.; Tasnim, Rumana; Samnan Haider, Syed; Shobaki, Mohammed M.; Shahid, Zeeshan

    2013-12-01

    A proliferating interest has been being observed over the past years in accurate wireless system development in order to monitor incessant human activities in health care centres. Furthermore because of the swelling number of elderly population and the inadequate number of competent staffs for nursing homes there is a big market petition for health care monitoring system. In order to detect human researchers developed different methods namely which include Field Identification technique, Visual Sensor Network, radar detection, e-mobile techniques and so on. An all-encompassing overview of the non-wired human detection application advancement is presented in this paper. Inductive links are used for human detection application while wiring an electronic system has become impractical in recent times. Keeping in mind the shortcomings, an Inductive Intelligent Sensor (IIS) has been proposed as a novel human monitoring system for future implementation. The proposed sensor works towards exploring the signature signals of human body movement and size. This proposed sensor is fundamentally based on inductive loop that senses the presence and a passing human resulting an inductive change.

  10. Experimental Study of 6LoPLC for Home Energy Management Systems

    Directory of Open Access Journals (Sweden)

    Augustine Ikpehai

    2016-12-01

    Full Text Available Ubiquitous connectivity is already transforming residential dwellings into smart homes. As citizens continue to embrace the smart home paradigm, a new generation of low-rate and low-power communication systems is required to leverage the mass market presented by energy management in homes. Although Power Line Communication (PLC technology has evolved in the last decade, the adaptation of PLC for constrained networks is not fully charted. By adapting some features of IEEE 802.15.4 and IPv6 over Low-power Wireless Personal Area Network (6LoWPAN into power lines, this paper demonstrates a low-rate, low-power PLC system over the IPv6 network (referred to as 6LoPLC, for Home Energy Management System (HEMS applications. The overall idea is to provide a framework for assessing various scenarios that cannot be easily investigated with the limited number of evaluation hardware available. In this respect, a network model is developed in NS-3 (Version 21 to measure several important characteristics of the designed system and then validated with experimental results obtained using the Hanadu evaluation kits. Following the good agreement between the two, the NS-3 model is utilised to investigate more complex scenarios and various use-cases, such as the effects of impulsive noise, the number of nodes and packet size on the latency and Bit Error Rate (BER performances. We further demonstrate that for different network and application configurations, optimal data sizes exist. For instance, the results reveal that in order to guarantee 99% system reliability, the HEMS application data must not exceed 64 bytes. Finally, it is shown that with impulsive noise in a HEMS network comprising 50 appliances, provided the size of the payload does not exceed 64 bytes, monitoring and control applications incur a maximum latency of 238.117 ms and 248.959 ms, respectively; both of which are within acceptable limits.

  11. Monitoring the CMS strip tracker readout system

    International Nuclear Information System (INIS)

    Mersi, S; Bainbridge, R; Cripps, N; Fulcher, J; Wingham, M; Baulieu, G; Bel, S; Delaere, C; Drouhin, F; Mirabito, L; Cole, J; Giassi, A; Gross, L; Hahn, K; Nikolic, M; Tkaczyk, S

    2008-01-01

    The CMS Silicon Strip Tracker at the LHC comprises a sensitive area of approximately 200 m 2 and 10 million readout channels. Its data acquisition system is based around a custom analogue front-end chip. Both the control and the readout of the front-end electronics are performed by off-detector VME boards in the counting room, which digitise the raw event data and perform zero-suppression and formatting. The data acquisition system uses the CMS online software framework to configure, control and monitor the hardware components and steer the data acquisition. The first data analysis is performed online within the official CMS reconstruction framework, which provides many services, such as distributed analysis, access to geometry and conditions data, and a Data Quality Monitoring tool based on the online physics reconstruction. The data acquisition monitoring of the Strip Tracker uses both the data acquisition and the reconstruction software frameworks in order to provide real-time feedback to shifters on the operational state of the detector, archiving for later analysis and possibly trigger automatic recovery actions in case of errors. Here we review the proposed architecture of the monitoring system and we describe its software components, which are already in place, the various monitoring streams available, and our experiences of operating and monitoring a large-scale system

  12. Computerized plutonium laboratory-stack monitoring system

    International Nuclear Information System (INIS)

    Stafford, R.G.; DeVore, R.K.

    1977-01-01

    The Los Alamos Scientific Laboratory has recently designed and constructed a Plutonium Research and Development Facility to meet design criteria imposed by the United States Energy Research and Development Administration. A primary objective of the design criteria is to assure environmental protection and to reliably monitor plutonium effluent via the ventilation exhaust systems. A state-of-the-art facility exhaust air monitoring system is described which establishes near ideal conditions for evaluating plutonium activity in the stack effluent. Total and static pressure sensing manifolds are incorporated to measure average velocity and integrated total discharge air volume. These data are logged at a computer which receives instrument data through a multiplex scanning system. A multipoint isokinetic sampling assembly with associated instrumentation is described. Continuous air monitors have been designed to sample from the isokinetic sampling assembly and transmit both instantaneous and integrated stack effluent concentration data to the computer and various cathode ray tube displays. The continuous air monitors also serve as room air monitors in the plutonium facility with the primary objective of timely evacuation of personnel if an above tolerance airborne plutonium concentration is detected. Several continuous air monitors are incorporated in the ventilation system to assist in identification of release problem areas

  13. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  14. Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)

  15. Carers' perceptions of the impact of home telehealth monitoring on the provision of care and sustainability of use.

    Science.gov (United States)

    Wade, Rachael; Cartwright, Colleen; Shaw, Kelly

    2015-06-01

    This paper aims to report carers' perceptions of the impact of home telehealth on the provision of care and the sustainability of home telehealth use. This paper is reporting on a sample of 15 carers who were involved in the telehealth arm of a larger controlled trial. Carers primarily believed that telehealth helped to provide better care. None of the carers had organised, or planned to organise, ongoing telehealth monitoring beyond the study. The main reason given for non-sustained usage was the belief that the person they cared for no longer required, or would benefit from, the monitoring. As the person being cared for was a frail older person with multiple chronic diseases and a history of recent hospitalisation, the non-sustained usage of home telehealth by carers raises questions about what is needed to ensure sustainability of use; this requires further investigation. © 2014 AJA Inc.

  16. Monitoring support system for nuclear power plant

    International Nuclear Information System (INIS)

    Higashikawa, Yuichi; Kubota, Rhuji; Tanaka, Keiji; Takano, Yoshiyuki

    1996-01-01

    The nuclear power plants in Japan reach to 49 plants and supply 41.19 million kW in their installed capacities, which is equal to about 31% of total electric power generation and has occupied an important situation as a stable energy supplying source. As an aim to keeping safe operation and working rate of the power plants, various monitoring support systems using computer technology, optical information technology and robot technology each advanced rapidly in recent year have been developed to apply to the actual plants for a plant state monitoring system of operators in normal operation. Furthermore, introduction of the emergent support system supposed on accidental formation of abnormal state of the power plants is also investigated. In this paper, as a monitoring system in the recent nuclear power plants, design of control panel of recent central control room, introduction to its actual plant and monitoring support system in development were described in viewpoints of improvement of human interface, upgrade of sensor and signal processing techniques, and promotion of information service technique. And, trend of research and development of portable miniature detector and emergent monitoring support system are also introduced in a viewpoint of labor saving and upgrade of the operating field. (G.K.)

  17. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  18. Agreement Between Home-Based Measurement of Stool Calprotectin and ELISA Results for Monitoring Inflammatory Bowel Disease Activity

    NARCIS (Netherlands)

    Heida, Anke; Knol, Mariska; Kobold, Anneke Muller; Bootsman, Josette; Dijkstra, Gerard; van Rheenen, Patrick F

    2017-01-01

    BACKGROUND & AIMS: An increasing number of physicians use repeated measurements of stool calprotectin to monitor intestinal inflammation in patients with inflammatory bowel diseases (IBDs). A lateral flow-based rapid test allows patients to measure their own stool calprotectin values at home. The

  19. Well Monitoring System For EGS

    Energy Technology Data Exchange (ETDEWEB)

    Normann, Randy [Perma Works LLC, Pattonville, TX (United States); Glowka, Dave [Perma Works LLC, Pattonville, TX (United States); Normann, Charles [Perma Works LLC, Pattonville, TX (United States); Parker, James [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Josip [Electrochemical Systems Inc, Knoxville, TN (United States); Dustan, Don [Electrochemical Systems Inc, Knoxville, TN (United States); Caja, Mario [Electrochemical Systems Inc, Knoxville, TN (United States); Sariri, Kouros [Frequency Management Int. Inc., Huntington Beach, CA (United States); Beal, Craig [MajiQ Technologies Inc., Somerville, MA (United States)

    2017-02-26

    This grant is a collection of projects designed to move aircraft high temperature electronics technology into the geothermal industry. Randy Normann is the lead. He licensed the HT83SNL00 chip from Sandia National Labs. This chip enables aircraft developed electronics for work within a geothermal well logging tool. However, additional elements are needed to achieve commercially successful logging tools. These elements are offered by a strong list of industrial partners on this grant as: Electrochemical Systems Inc. for HT Rechargeable Batteries, Frequency Management Systems for 300C digital clock, Sandia National Labs for experts in high temperature solder, Honeywell Solid-State Electronics Center for reprogrammable high temperature memory. During the course of this project MagiQ Technologies for high temperature fiber optics.

  20. Amplified OTDR Systems for Multipoint Corrosion Monitoring

    Science.gov (United States)

    Nascimento, Jehan F.; Silva, Marcionilo J.; Coêlho, Isnaldo J. S.; Cipriano, Eliel; Martins-Filho, Joaquim F.

    2012-01-01

    We present two configurations of an amplified fiber-optic-based corrosion sensor using the optical time domain reflectometry (OTDR) technique as the interrogation method. The sensor system is multipoint, self-referenced, has no moving parts and can measure the corrosion rate several kilometers away from the OTDR equipment. The first OTDR monitoring system employs a remotely pumped in-line EDFA and it is used to evaluate the increase in system reach compared to a non-amplified configuration. The other amplified monitoring system uses an EDFA in booster configuration and we perform corrosion measurements and evaluations of system sensitivity to amplifier gain variations. Our experimental results obtained under controlled laboratory conditions show the advantages of the amplified system in terms of longer system reach with better spatial resolution, and also that the corrosion measurements obtained from our system are not sensitive to 3 dB gain variations. PMID:22737017

  1. Hypoxia, Monitoring, and Mitigation System

    Science.gov (United States)

    2015-08-01

    art_psych_combat.htm “Humans have three primary survival systems: vision, cognitive processing, and motor skill performance. Under stress , all...fundamental truth of modern combat is that the stress of facing close-range interpersonal aggression is so great that, if endured for months on end without... Stroop Test. However these authors felt that improved cognitive function may be due to cerebral neural activation associated with exercise rather

  2. Radiation monitoring system in medical facilities

    International Nuclear Information System (INIS)

    Matsuno, Kiyoshi

    1981-01-01

    (1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)

  3. ATLAS Tile calorimeter calibration and monitoring systems

    CERN Document Server

    Marjanovic, Marija; The ATLAS collaboration

    2018-01-01

    The ATLAS Tile Calorimeter (TileCal) is the central section of the hadronic calorimeter of the ATLAS experiment. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibers to photo-multiplier tubes (PMTs), located in the outer part of the calorimeter. The readout is segmented into about 5000 cells, each one being read out by two PMTs in parallel. To calibrate and monitor the stability and performance of the full readout chain during the data taking, a set of calibration sub-systems is used. The TileCal calibration system comprises Cesium radioactive sources, laser, charge injection elements, and an integrator based readout system. Combined information from all systems allows to monitor and to equalize the calorimeter response at each stage of the signal evolution, from scintillation light to digitization. Calibration runs are monitored from a data quality perspective and u...

  4. An automated neutron monitor maintenance system

    International Nuclear Information System (INIS)

    Moore, F.S.; Griffin, J.C.; Odell, D.M.C.

    1996-01-01

    Neutron detectors are commonly used by the nuclear materials processing industry to monitor fissile materials in process vessels and tanks. The proper functioning of these neutron monitors must be periodically evaluated. We have developed and placed in routine use a PC-based multichannel analyzer (MCA) system for on-line BF3 and He-3 gas-filled detector function testing. The automated system: 1) acquires spectral data from the monitor system, 2) analyzes the spectrum to determine the detector's functionality, 3) makes suggestions for maintenance or repair, as required, and 4) saves the spectrum and results to disk for review. The operator interface has been designed to be user-friendly and to minimize the training requirements of the user. The system may also be easily customized for various applications

  5. Integrated environmental monitoring and information system

    International Nuclear Information System (INIS)

    Klinda, J.; Lieskovska, Z.

    1998-01-01

    The concept of the environmental monitoring within the territory of the Slovak Republic and the concept of the integrated environmental information system of the Slovak Republic were accepted and confirmed by the Government Order No. 449/1992. The state monitoring system covering the whole territory of Slovakia is the most important and consists of 13 Partial Monitoring Systems (PMSs). List of PMSs is included. The listed PMSs are managed according to the concept of the Sectoral Information System (SIS) of the Ministry of the Environment of the Slovak Republic (MESR) which was established by the National Council Act No. 261/1995 Coll. on the SIS. The SIS consists of 18 subsystems which are listed. The overviews of budget of PMSs as well as of environmental publications and periodicals of the MESR are included

  6. Pickering Nuclear site wide groundwater monitoring system

    International Nuclear Information System (INIS)

    DeWilde, J.; Chin-Cheong, D.; Lledo, C.; Wootton, R.; Belanger, D.; Hansen, K.

    2001-01-01

    Ontario Power Generation Inc. (OPG) is continuing its efforts to understand the chemical and physical characteristics of the groundwater flow systems beneath the Pickering Nuclear Generating Station (PNGS). To this end, OPG constructed a site-wide Groundwater Monitoring System (GMS) at the PNGS to provide support to other ongoing environmental investigations and to provide a means to monitor current and future groundwater environmental issues. This paper will present the results of this work, including the development of a state-of-the-art data management system for storage and retrieval of environmental data for the site, which has applications for other power generation facilities. (author)

  7. Modernization of WWER-1000 radiation monitoring systems

    International Nuclear Information System (INIS)

    Smith, T.

    1995-01-01

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs

  8. Modernization of WWER-1000 radiation monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T [General Atomics, San Diego, CA (United States)

    1996-12-31

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs.

  9. The AGS Booster Beam Position Monitor system

    International Nuclear Information System (INIS)

    Ciardullo, D.J.; Abola, A.; Beadle, E.R.; Smith, G.A.; Thomas, R.; Van Zwienen, W.; Warkentien, R.; Witkover, R.L.

    1991-01-01

    To accelerate both protons and heavy ions, the AGS Booster requires a broadband (multi-octave) beam position monitoring system with a dynamic range spanning several orders of magnitude (2 x 10 10 to 1.5 x 10 13 particles per pulse). System requirements include the ability to acquire single turn trajectory and average orbit information with ± 0.1 mm resolution. The design goal of ± 0.5 mm corrected accuracy requires that the detectors have repeatable linear performance after periodic bakeout at 300 degree C. The system design and capabilities of the Booster Beam Position Monitor will be described, and initial results presented. 7 refs., 5 figs

  10. Development of the simulation monitoring system

    International Nuclear Information System (INIS)

    Kato, Katsumi; Watanabe, Tadashi; Kume, Etsuo

    2001-01-01

    Large-scale simulation technique is studied at the Center for Promotion of Computational Science and Engineering for the computational science research in nuclear fields. Visualization and animation processing techniques are developed for efficient understanding of simulation results. The development of the simulation monitoring system, which is used for real-time visualization of ongoing simulations or for successive visualization of calculated results, is described in this report. The standard visualization tool AVS5 or AVS/EXPRESS is used for the simulation monitoring system, and thus, this system can be utilized in various computer environments. (author)

  11. Embedded data acquisition system for neutron monitors

    International Nuclear Information System (INIS)

    Población, Ó G; Tejedor, I G; Sánchez, S; Blanco, J J; Gómez-Herrero, R; Medina, J; Steigies, C T

    2014-01-01

    This article presents the design and implementation of a new data acquisition system to be used as replacement for the old ones that have been in use with neutron monitors for the last decades and, which are eventually becoming obsolete. This new system is also intended to be used in new installations, enabling these scientific instruments to use today's communication networks to send data and receive commands from the operators. This system is currently running in two stations: KIEL2, in the Christian-Albrechts-Universität zu Kiel, Kiel, Germany, and CALMA, in the Castilla-La Mancha Neutron Monitor, Guadalajara, Spain

  12. Ambulatory and home blood pressure monitoring: gaps between clinical guidelines and clinical practice in Singapore

    Directory of Open Access Journals (Sweden)

    Setia S

    2017-07-01

    Full Text Available Sajita Setia,1 Kannan Subramaniam,2 Boon Wee Teo,3 Jam Chin Tay4 1Chief Medical Office, Medical Affairs, Pfizer Pte Ltd, Singapore; 2Global Medical Affairs, Asia Pacific Region, Pfizer Australia, West Ryde, New South Wales, Australia; 3Department of Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; 4Department of General Medicine, Tan Tock Seng Hospital, Singapore Purpose: Out-of-office blood pressure (BP measurements (home blood pressure monitoring [HBPM] and ambulatory blood pressure monitoring [ABPM] provide important additional information for effective hypertension detection and management decisions. Therefore, out-of-office BP measurement is now recommended by several international guidelines. This study evaluated the practice and uptake of HBPM and ABPM among physicians from Singapore. Materials and methods: A sample of physicians from Singapore was surveyed between 8 September and 5 October 2016. Those included were in public or private practice had been practicing for ≥3 years, directly cared for patients ≥70% of the time, and treated ≥30 patients for hypertension per month. The questionnaire covered six main categories: general BP management, BP variability (BPV awareness/diagnosis, HBPM, ABPM, BPV management, and associated training needs. Results: Sixty physicians (30 general practitioners, 20 cardiologists, and 10 nephrologists were included (77% male, 85% aged 31–60 years, and mean 22-year practice. Physicians recommended HBPM and ABPM to 81% and 27% of hypertensive patients, respectively. HBPM was most often used to monitor antihypertensive therapy (88% of physicians and 97% thought that ABPM was useful for providing information on BPV. HBPM instructions often differed from current guideline recommendations in terms of frequency, number of measurements, and timing. The proportion of consultation time devoted to discussing HBPM and BPV was one-quarter or less for 73% of physicians, and

  13. Standard monitoring system for domestic heat pumps

    NARCIS (Netherlands)

    Geelen, C.P.J.M.; Oostendorp, P.A.

    1999-01-01

    In the years to come many domestic heat pump systems are to be installed in the Netherlands. The Dutch agency for energy and environment, NOVEM, and the association of energy utility companies, EnergieNed, give high priority to the monitoring of heat pump systems. The results of the projects,

  14. Psychometric aspects of pupil monitoring systems

    NARCIS (Netherlands)

    Glas, Cornelis A.W.; Geerlings, Hanneke

    2009-01-01

    Pupil monitoring systems support the teacher in tailoring teaching to the individual level of a student and in comparing the progress and results of teaching with national standards. The systems are based on the availability of an item bank calibrated using item response theory. The assessment of

  15. A system for environmental monitoring

    International Nuclear Information System (INIS)

    Tawil, R.A.; Velbeck, K.J.; Rotunda, J.E.; Flory, C.; Moscovitch, M.

    1993-01-01

    The system described in this paper consists of a reader, multi-element dosemeters, and dose algorithm. The reader is a medium capacity non-contact gas heating unit interfaced to an application software package that evaluates and manages generated data. The dosemeter consists of elements that are 240 mg.cm -2 thick and which are symmetrically filtered. The two CaF 2 :Dy (TLD-200) elements are shielded by 80 mg.cm -2 ABS plastic, 0.25 mm tantalum and 0.05 mm lead. The two LiF:Mg,Ti (TLD-100) are shielded by the 80 mg.cm -2 ABS plastic only. The response of this system was characterised according to the criteria established in the ANSI Standard N545, Section 4, as modified by NRC Regulatory Guide 4.13. The procedures applied to study the energy response, fading, linearity, uniformity, minimum detectability, reproducibility, reponse dependence on angle of incidence are described, reviewed, and the results presented. The study also included self-irradiation, sensitivity to light and moisture, and performance in actual field conditions. The results demonstrate that this dosemeter satisfies all of the N545-1975 performance requirements. The dose calculation algorithm developed for this dosemeter is outlined and the accuracy of its performance in various pure and mixed fields has been determined. The results are presented and discussed. (author)

  16. Shared performance monitor in a multiprocessor system

    Science.gov (United States)

    Chiu, George; Gara, Alan G.; Salapura, Valentina

    2012-07-24

    A performance monitoring unit (PMU) and method for monitoring performance of events occurring in a multiprocessor system. The multiprocessor system comprises a plurality of processor devices units, each processor device for generating signals representing occurrences of events in the processor device, and, a single shared counter resource for performance monitoring. The performance monitor unit is shared by all processor cores in the multiprocessor system. The PMU comprises: a plurality of performance counters each for counting signals representing occurrences of events from one or more the plurality of processor units in the multiprocessor system; and, a plurality of input devices for receiving the event signals from one or more processor devices of the plurality of processor units, the plurality of input devices programmable to select event signals for receipt by one or more of the plurality of performance counters for counting, wherein the PMU is shared between multiple processing units, or within a group of processors in the multiprocessing system. The PMU is further programmed to monitor event signals issued from non-processor devices.

  17. Wireless network system based multi-non-invasive sensors for smart home

    Science.gov (United States)

    Issa Ahmed, Rudhwan

    There are several techniques that have been implemented for smart homes usage; however, most of these techniques are limited to a few sensors. Many of these methods neither meet the needs of the user nor are cost-effective. This thesis discusses the design, development, and implementation of a wireless network system, based on multi-non-invasive sensors for smart home environments. This system has the potential to be used as a means to accurately, and remotely, determine the activities of daily living by continuously monitoring relatively simple parameters that measure the interaction between users and their surrounding environment. We designed and developed a prototype system to meet the specific needs of the elderly population. Unlike audio-video based health monitoring systems (which have associated problems such as the encroachment of privacy), the developed system's distinct features ensure privacy and are almost invisible to the occupants, thus increasing the acceptance levels of this system in household environments. The developed system not only achieved high levels of accuracy, but it is also portable, easy to use, cost-effective, and requires low data rates and less power compared to other wireless devices such as Wi-Fi, Bluetooth, wireless USB, Ultra wideband (UWB), or Infrared (IR) wireless. Field testing of the prototype system was conducted at different locations inside and outside of the Minto Building (Centre for Advanced Studies in Engineering at Carleton University) as well as other locations, such as the washroom, kitchen, and living room of a prototype apartment. The main goal of the testing was to determine the range of the prototype system and the functionality of each sensor in different environments. After it was verified that the system operated well in all of the tested environments, data were then collected at the different locations for analysis and interpretation in order to identify the activities of daily living of an occupant.

  18. Radiachromic: a radiation monitoring system

    International Nuclear Information System (INIS)

    Humpherys, K.C.; Kantz, A.D.

    1977-01-01

    Various plastic film materials have been utilized to measure radiation fields. The radiachromic materials have been found to have advantages in reproducibility, stability, equivalent response to electrons and gamma ray fields, dose rate dependence and negligible variation for most environmental parameters. A simple photometer has been developed for read-out. The physical and chemical properties of the total system are described. A standard radiachromic has been selected for application to radiation processing. This material has a dose range of 5 x 10 4 to 3 x 10 7 rads, no dose rate effects to above 4 x 10 14 R/sec, an equivalent response to electrons and gamma rays, shelf life of greater than one year. Other forms are also applicable to radiation processing. (author)

  19. Monitoring of noninvasive ventilation by built-in software of home bilevel ventilators: a bench study.

    Science.gov (United States)

    Contal, Olivier; Vignaux, Laurence; Combescure, Christophe; Pepin, Jean-Louis; Jolliet, Philippe; Janssens, Jean-Paul

    2012-02-01

    Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.

  20. Sizing solar home systems for optimal development impact

    International Nuclear Information System (INIS)

    Bond, M.; Fuller, R.J.; Aye, Lu

    2012-01-01

    The paper compares the development impact of three different sized solar home systems (SHS) (10, 40 and 80 W p ) installed in rural East Timor. It describes research aimed to determine whether the higher cost of the larger systems was justified by additional household benefits. To assess the development impact of these different sizes of SHS the research used a combination of participatory and quantitative tools. Participatory exercises were conducted with seventy-seven small groups of SHS users in twenty-four rural communities and supplemented with a household survey of 195 SHS users. The combined results of these evaluation processes enabled the three sizes of SHS to be compared for two types of benefits—those associated with carrying out important household tasks and attributes of SHS which were advantageous compared to the use of non-electric lighting sources. The research findings showed that the small, 10 W p SHS provided much of the development impact of the larger systems. It suggests three significant implications for the design of SHS programs in contexts such as East Timor: provide more small systems rather than fewer large ones; provide lighting in the kitchen wherever possible; and carefully match SHS operating costs to the incomes of rural users. - Highlights: ► We compare development benefits for 3 sizes of solar home systems—10, 40 and 80 W p . ► Benefit assessment uses a combination of qualitative and quantitative approaches. ► Small systems are found to provide much of the benefits of the larger systems. ► To maximise benefits systems should be fitted with luminaires in kitchen areas. ► Financial benefits are important to users and may not accrue for large systems.

  1. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  2. A Novel Secure IoT-Based Smart Home Automation System Using a Wireless Sensor Network.

    Science.gov (United States)

    Pirbhulal, Sandeep; Zhang, Heye; E Alahi, Md Eshrat; Ghayvat, Hemant; Mukhopadhyay, Subhas Chandra; Zhang, Yuan-Ting; Wu, Wanqing

    2016-12-30

    Wireless sensor networks (WSNs) provide noteworthy benefits over traditional approaches for several applications, including smart homes, healthcare, environmental monitoring, and homeland security. WSNs are integrated with the Internet Protocol (IP) to develop the Internet of Things (IoT) for connecting everyday life objects to the internet. Hence, major challenges of WSNs include: (i) how to efficiently utilize small size and low-power nodes to implement security during data transmission among several sensor nodes; (ii) how to resolve security issues associated with the harsh and complex environmental conditions during data transmission over a long coverage range. In this study, a secure IoT-based smart home automation system was developed. To facilitate energy-efficient data encryption, a method namely Triangle Based Security Algorithm (TBSA) based on efficient key generation mechanism was proposed. The proposed TBSA in integration of the low power Wi-Fi were included in WSNs with the Internet to develop a novel IoT-based smart home which could provide secure data transmission among several associated sensor nodes in the network over a long converge range. The developed IoT based system has outstanding performance by fulfilling all the necessary security requirements. The experimental results showed that the proposed TBSA algorithm consumed less energy in comparison with some existing methods.

  3. A Novel Secure IoT-Based Smart Home Automation System Using a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Sandeep Pirbhulal

    2016-12-01

    Full Text Available Wireless sensor networks (WSNs provide noteworthy benefits over traditional approaches for several applications, including smart homes, healthcare, environmental monitoring, and homeland security. WSNs are integrated with the Internet Protocol (IP to develop the Internet of Things (IoT for connecting everyday life objects to the internet. Hence, major challenges of WSNs include: (i how to efficiently utilize small size and low-power nodes to implement security during data transmission among several sensor nodes; (ii how to resolve security issues associated with the harsh and complex environmental conditions during data transmission over a long coverage range. In this study, a secure IoT-based smart home automation system was developed. To facilitate energy-efficient data encryption, a method namely Triangle Based Security Algorithm (TBSA based on efficient key generation mechanism was proposed. The proposed TBSA in integration of the low power Wi-Fi were included in WSNs with the Internet to develop a novel IoT-based smart home which could provide secure data transmission among several associated sensor nodes in the network over a long converge range. The developed IoT based system has outstanding performance by fulfilling all the necessary security requirements. The experimental results showed that the proposed TBSA algorithm consumed less energy in comparison with some existing methods.

  4. A Novel Secure IoT-Based Smart Home Automation System Using a Wireless Sensor Network

    Science.gov (United States)

    Pirbhulal, Sandeep; Zhang, Heye; E Alahi, Md Eshrat; Ghayvat, Hemant; Mukhopadhyay, Subhas Chandra; Zhang, Yuan-Ting; Wu, Wanqing

    2016-01-01

    Wireless sensor networks (WSNs) provide noteworthy benefits over traditional approaches for several applications, including smart homes, healthcare, environmental monitoring, and homeland security. WSNs are integrated with the Internet Protocol (IP) to develop the Internet of Things (IoT) for connecting everyday life objects to the internet. Hence, major challenges of WSNs include: (i) how to efficiently utilize small size and low-power nodes to implement security during data transmission among several sensor nodes; (ii) how to resolve security issues associated with the harsh and complex environmental conditions during data transmission over a long coverage range. In this study, a secure IoT-based smart home automation system was developed. To facilitate energy-efficient data encryption, a method namely Triangle Based Security Algorithm (TBSA) based on efficient key generation mechanism was proposed. The proposed TBSA in integration of the low power Wi-Fi were included in WSNs with the Internet to develop a novel IoT-based smart home which could provide secure data transmission among several associated sensor nodes in the network over a long converge range. The developed IoT based system has outstanding performance by fulfilling all the necessary security requirements. The experimental results showed that the proposed TBSA algorithm consumed less energy in comparison with some existing methods. PMID:28042831

  5. Real world implementation lessons and outcomes from the Worker Interactive Networking (WIN) project: workplace-based online caregiver support and remote monitoring of elders at home.

    Science.gov (United States)

    Mahoney, Diane M F; Mutschler, Phyllis H; Tarlow, Barbara; Liss, Ellen

    2008-04-01

    The objective of this research was to determine the feasibility of and receptivity to the first computerized workplace-based direct caregiver intervention and to assess the effects on businesses, working family caregivers, and their elderly relatives. Working family caregivers, with at least one health and/or safety concern related to an elder residing alone at home during the workday, were recruited from five companies (n = 27). Caregivers received free computer access to the Worker Interactive Networking (WIN) Internet online caregiver support group and a remote elder monitoring system at home for 6 months. The remote monitoring system provided Web-based status reports and e-mail/pager alerts when individualized parameters were exceeded. Motion sensor signals were transmitted to a transponder that uploaded via wireless cellular communications to the project server, thereby not interfering with elders' telephone use. Formative qualitative analyses clarified acceptance and implementation issues. Summative quantitative evaluation determined pilot intervention effects and was conducted by external evaluators. Despite interoperability and cellular reception issues, the system was successfully deployed across four states to a variety of businesses and housing types. Positive results occurred on worker morale, productivity, and reduction of caregiver stress. Participants found it easy to learn and use. Elders did not find the technology "intrusive" or "isolating." Contrary to their expectations, managers reported no abuse of Internet access. Workers expressed a willingness to pay for a similar system in the future ranging from $10 to $130, depending on the features. They would pay the most for the option involving a geriatric nurse coach. The WIN system innovatively tailored to users' wants, and provided users customized control and personalized support. Use of the system was associated with positive outcomes. Enrollment response suggests a specific niche market for

  6. The Design and Implementation of Smart Monitoring System for Large-Scale Railway Maintenance Equipment Cab Based on ZigBee Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Hairui Wang

    2014-06-01

    Full Text Available In recent years, organizations use IEEE 802.15.4 and ZigBee technology to deliver solution in variety areas including home environment monitoring. ZigBee technology has advantages on low-cost, low power consumption and self-forming. With the rapid expansion of the Internet, there is the requirement for remote monitoring large-scale railway maintenance equipment cab. This paper discusses the disadvantages of the existing smart monitoring system, and proposes a solution. A ZigBee wireless sensor network smart monitoring system and Wi-Fi network is integrated through a home gateway to increase the system flexibility. At the same time the home gateway cooperated with a pre- processing system provide a flexible user interface, and the security and safety of the smart monitoring system. To testify the efficiency of the proposed system, the temperature and humidity sensors and light sensors have developed and evaluated in the smart monitoring system.

  7. OPTIMIZATION METHODS FOR HYDROECOLOGICAL MONITORING SYSTEMS

    Directory of Open Access Journals (Sweden)

    Inna Pivovarova

    2016-09-01

    Full Text Available The paper describes current approaches to the rational distribution of monitoring stations. A short review and the organization of the system of hydro-geological observations in different countries are presented. On the basis of real data we propose a solution to the problem of how to calculate the average area per one hydrological station, which is the main indicator of the efficiency and performance of the monitoring system in general. We conclude that a comprehensive approach to the monitoring system organization is important, because only hydrometric and hydrochemical activities coordinated in time provide possibilities needed to analyse the underline causes of the observed pollutants content dynamics in water bodies in the long term.

  8. LHCb: Monitoring the DIRAC Distribution System

    CERN Multimedia

    Nandakumar, R; Santinelli, R

    2009-01-01

    DIRAC is the LHCb gateway to any computing grid infrastructure (currently supporting WLCG) and is intended to reliably run large data mining activities. The DIRAC system consists of various services (which wait to be contacted to perform actions) and agents (which carry out periodic activities) to direct jobs as required. An important part of ensuring the reliability of the infrastructure is the monitoring and logging of these DIRAC distributed systems. The monitoring is done collecting information from two sources - one is from pinging the services or by keeping track of the regular heartbeats of the agents, and the other from the analysis of the error messages generated by both agents and services and collected by the logging system. This allows us to ensure that he components are running properly and to collect useful information regarding their operations. The process status monitoring is displayed using the SLS sensor mechanism which also automatically allows one to plot various quantities and also keep ...

  9. Data-acquisition system for radon monitoring

    International Nuclear Information System (INIS)

    Franklin, J.C.; Zawadzki, R.J.; Meyer, T.O.; Hill, A.L.

    1976-01-01

    A data-acquisition system was designed by the Bureau of Mines to monitor five detectors with radon continuously flowing through each. These detectors could be monitored up to 12 times an hour, but were only monitored according to a preset time, thus allowing radon to be monitored continuously in a uranium mine. The counter can be set to monitor each detector for any period of time up to 16.5 minutes. This allows very low concentrations to be monitored longer to reduce statistical error. There would be no upper limit in radon concentration that could be monitored, but there would be a lower limit of 50 pCi/l. Each detector was calibrated by the Lucas flask method. Multiple samples were taken at two different concentrations, and the correction factor for each detector was determined by a least squares fit of the data. To verify the calibrations, a series of measurements at several concentrations were made against a constant source. The agreement at low radon concentrations (300 pCi/l) with the two-filter method was within 3 percent; thus, the total error would be this difference plus the two-filter error. At high concentrations, the coefficient of variation ranged between 2.1 and 9.8 percent for the five different detector units

  10. Design of BEPCII bunch current monitor system

    International Nuclear Information System (INIS)

    Zhang Lei; Ma Huizhou; Yue Junhui; Lei Ge; Cao Jianshe; Ma Li

    2008-01-01

    BEPC II is an electron-positron collider designed to run under multi-bunches and high beam current condition. The accelerator consists of an electron ring, a positron ring and a linear injector. In order to achieve the target luminosity and implement the equal bunch charge injection, the Bunch Current Monitor (BCM) system is built on BEPC II. The BCM system consists of three parts: the front-end circuit, the bunch current acquisition system and the bucket selection system. The control software of BCM is based on VxWorks and EPICS. With the help of BCM system, the bunch current in each bucket can be monitored in the Central Control Room. The BEPC II timing system can also use the bunch current database to decide which bucket needs to refill to implement 'top-off' injection. (authors)

  11. Smart Sensor Network System For Environment Monitoring

    Directory of Open Access Journals (Sweden)

    Javed Ali Baloch

    2012-07-01

    Full Text Available SSN (Smart Sensor Network systems could be used to monitor buildings with modern infrastructure, plant sites with chemical pollution, horticulture, natural habitat, wastewater management and modern transport system. To sense attributes of phenomena and make decisions on the basis of the sensed value is the primary goal of such systems. In this paper a Smart Spatially aware sensor system is presented. A smart system, which could continuously monitor the network to observe the functionality and trigger, alerts to the base station if a change in the system occurs and provide feedback periodically, on demand or even continuously depending on the nature of the application. The results of the simulation trials presented in this paper exhibit the performance of a Smart Spatially Aware Sensor Networks.

  12. Monitoring SLAC High Performance UNIX Computing Systems

    International Nuclear Information System (INIS)

    Lettsome, Annette K.

    2005-01-01

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia. Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface

  13. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-01-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  14. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  15. A dose monitoring system for dental radiography

    International Nuclear Information System (INIS)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul; Symkhampha, Khanthaly; Lee, Woo Jin; Yeom, Heon Young

    2016-01-01

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose

  16. A high reliability oxygen deficiency monitoring system

    International Nuclear Information System (INIS)

    Parry, R.; Claborn, G.; Haas, A.; Landis, R.; Page, W.; Smith, J.

    1993-05-01

    The escalating use of cryogens at national laboratories in general and accelerators in particular, along with the increased emphasis placed on personnel safety, mandates the development and installation of oxygen monitoring systems to insure personnel safety in the event of a cryogenic leak. Numerous vendors offer oxygen deficiency monitoring systems but fail to provide important features and/or flexibility. This paper describes a unique oxygen monitoring system developed for the Magnet Test Laboratory (MTL) at the Superconducting Super Collider Laboratory (SSCL). Features include: high reliability, oxygen cell redundancy, sensor longevity, simple calibration, multiple trip points, offending sensor audio and visual indication, global alarms for building evacuation, local and remote analog readout, event and analog data logging, EMAIL event notification, phone line voice status system, and multi-drop communications network capability for reduced cable runs. Of particular importance is the distributed topology of the system which allows it to operate in a stand-alone configuration or to communicate with a host computer. This flexibility makes it ideal for small applications such as a small room containing a cryogenic dewar, as well as larger systems which monitor many offices and labs in several buildings

  17. Trend Monitoring System (TMS) graphics software

    Science.gov (United States)

    Brown, J. S.

    1979-01-01

    A prototype bus communications systems, which is being used to support the Trend Monitoring System (TMS) and to evaluate the bus concept is considered. A set of FORTRAN-callable graphics subroutines for the host MODCOMP comuter, and an approach to splitting graphics work between the host and the system's intelligent graphics terminals are described. The graphics software in the MODCOMP and the operating software package written for the graphics terminals are included.

  18. GSM BASED IRRIGATION CONTROL AND MONITORING SYSTEM

    OpenAIRE

    GODFREY A. MILLS; STEPHEN K. ARMOO; AGYEMAN K. ROCKSON; ROBERT A. SOWAH; MOSES A. ACQUAH

    2013-01-01

    Irrigated agriculture is one of the primary water consumers in most parts of the world. With developments in technology, efforts are being channeled into automation of irrigation systems to facilitate remote control of the irrigation system and optimize crop production and cost effectiveness. This paper describes an on-going work on GSM based irrigation monitoring and control systems. The objective of the work is to provide an approach that helps farmers to easily access, manage and regulate ...

  19. Data Center Equipment Location and Monitoring System

    DEFF Research Database (Denmark)

    2013-01-01

    Abstract: Data center equipment location systems include hardware and software to provide information on the location, monitoring, and security of servers and other equipment in equipment racks. The systems provide a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to an equipment rack controller on the equipment rack. The equipment rack controllers link to a central control computer that provides an operator ...

  20. [Development of automatic urine monitoring system].

    Science.gov (United States)

    Wei, Liang; Li, Yongqin; Chen, Bihua

    2014-03-01

    An automatic urine monitoring system is presented to replace manual operation. The system is composed of the flow sensor, MSP430f149 single chip microcomputer, human-computer interaction module, LCD module, clock module and memory module. The signal of urine volume is captured when the urine flows through the flow sensor and then displayed on the LCD after data processing. The experiment results suggest that the design of the monitor provides a high stability, accurate measurement and good real-time, and meets the demand of the clinical application.

  1. Design of Wind Turbine Vibration Monitoring System

    Directory of Open Access Journals (Sweden)

    Shoubin Wang

    2013-04-01

    Full Text Available In order to ensure safety of wind turbine operation and to reduce the occurrence of faults as well as to improve the reliability of wind turbine operation, a vibration monitoring for wind turbine is developed. In this paper, it analyses the enlargement of all the parts of the structure and the working mechanism, the research method of wind turbine operation vibration is introduced, with the focus being the use of the sensor principle. Finally the hardware design and software of this system is introduced and the main function of this system is described, which realizes condition monitoring of the work state of wind turbines.

  2. Air Quality Monitoring System and Benchmarking

    DEFF Research Database (Denmark)

    Liu, Xiufeng; Nielsen, Per Sieverts

    2017-01-01

    Air quality monitoring has become an integral part of smart city solutions. This paper presents an air quality monitoring system based on Internet of Things (IoT) technologies, and establishes a cloud-based platform to address the challenges related to IoT data management and processing capabilit...... capabilities, including data collection, storage, analysis, and visualization. In addition, this paper also benchmarks four state-of-the-art database systems to investigate the appropriate technologies for managing large-scale IoT datasets....

  3. Simple MoCap System for Home Usage

    Directory of Open Access Journals (Sweden)

    Martin Magdin

    2017-08-01

    Full Text Available Nowadays many MoCap systems exist. Generating 3D facial animation of characters is currently realized by using the motion capture data (MoCap data, which is obtained by tracking the facial markers from an actor/actress. In general it is a professional solution that is sophisticated and costly. This paper presents a solution with a system that is inexpensive. We propose a new easy-to-use system for home usage, through which we are making character animation. In its implementation we paid attention to the elimination of errors from the previous solutions. In this paper the authors describe the method how motion capture characters on a treadmill and as well as an own Java application that processes the video for its further use in Cinema 4D. This paper describes the implementation of this technology of sensing in a way so that the animated character authentically imitated human movement on a treadmill.

  4. Hanger-type laundry monitor system

    International Nuclear Information System (INIS)

    Aoyama, Kei; Kouno, Yoshio; Yanagishima, Ryouhei; Ikeda, Yasuyuki; Nakatani, Masahiro

    1987-01-01

    Laundry monitor is installed in nuclear power plants or other nuclear facilities in order to efficiently detect radioactive contamination remains on the surfaces of the working clothes which were used in the controlled area and washed afterward. The number of the working clothes which must be measured has been increasing in accordance with the increase of the nuclear facilities. This fact and recent intensified radiation control require automatic, high-speed and high sensitive measurement. Conveyer-type laundry monitor in which the working clothes are inserted by the metal net conveyer has been generally used, and recently new system with an automatic folder has become more popular. But, this type of system has not so big capacity because the clothes are conveyed longitudinally and also requires considerable wide space when installed. Fuji electric Co., Ltd. has been engaging in research and development for an optimum laundry monitor system used in nuclear facilities since the joint investigation with ten electric power companies in Japan in 1982. Consequently hanger-type laundry monitor system using automatic hanger conveyer was developed and 2 systems were delivered to Chubu Electric Power Co., Ltd. in 1986. This system permits to detect radioactive contamination on the working clothes, pick the contaminated clothes out and fold the uncontaminated clothes fully automatically and continuously. Moreover it allows to shorten the measurement time because the clothes are conveyed transversely and save the installation space, so that this will be regarded as considerably complete system in the world. This report describes the outline of the hanger-type laundry monitor system. (author)

  5. Evaluation of a multiport groundwater monitoring system

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Hall, S.H.; Olsen, K.B.; Spane, F.A. Jr.

    1991-03-01

    In 1988 and 1989, Pacific Northwest Laboratory installed a multiport groundwater monitoring system in two wells on the Hanford Site: one near the 216-B-3 Pond in the center of the Hanford Site and one just north of the 300 Area near the Columbia River. The system was installed to provide the US Department of Energy with needed three-dimensional data on the vertical distribution of contaminants and hydraulic heads on the Hanford Site. This study evaluates the ability of the multiport system to obtain hydrogeologic data at multiple points vertically in a single borehole, and addresses the representativeness of the data. Data collected from the two wells indicate that the multiport system is well suited for groundwater monitoring networks requiring three-dimensional characterization of the hydrogeologic system. A network of these systems could provide valuable information on the hydrogeologic environment. However, the advantages of the multiport system diminish when the system is applied to long-term monitoring networks (30+ years) and to deeper wells (<300 ft). For shallow wells, the multiport system provides data in a cost-effective manner that would not be reasonably obtainable with the conventional methods currently in use at the Hanford Site. 17 refs., 28 figs., 6 tabs

  6. National Satellite Forest Monitoring systems for REDD+

    Science.gov (United States)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows

  7. Decision Fusion System for Bolted Joint Monitoring

    Directory of Open Access Journals (Sweden)

    Dong Liang

    2015-01-01

    Full Text Available Bolted joint is widely used in mechanical and architectural structures, such as machine tools, industrial robots, transport machines, power plants, aviation stiffened plate, bridges, and steel towers. The bolt loosening induced by flight load and environment factor can cause joint failure leading to a disastrous accident. Hence, structural health monitoring is critical for the bolted joint detection. In order to realize a real-time and convenient monitoring and satisfy the requirement of advanced maintenance of the structure, this paper proposes an intelligent bolted joint failure monitoring approach using a developed decision fusion system integrated with Lamb wave propagation based actuator-sensor monitoring method. Firstly, the basic knowledge of decision fusion and classifier selection techniques is briefly introduced. Then, a developed decision fusion system is presented. Finally, three fusion algorithms, which consist of majority voting, Bayesian belief, and multiagent method, are adopted for comparison in a real-world monitoring experiment for the large aviation aluminum plate. Based on the results shown in the experiment, a big potential in real-time application is presented that the method can accurately and rapidly identify the bolt loosening by analyzing the acquired strain signal using proposed decision fusion system.

  8. Background compensation methodologies for contamination monitoring systems

    International Nuclear Information System (INIS)

    Raman, Anand; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiation surveillance program in the various nuclear facilities incorporate contamination monitoring as an important component. Contamination monitoring programs constitute monitoring for alpha and beta contamination of the physical entities associated with the working personnel that include his hands, feet, clothing, shoes as well as the general surface areas in the working environment like floors. All these measurements are fraught with the contribution of the ambient gamma background radiation fields. These inhibit a proper and precise estimation of the contamination concentration being monitored. This paper investigates the efficacy of two methodologies that have been incorporated in two of the contamination monitoring systems developed in the Division. In the first system discussed, a high degree of gamma compensation has been achieved for an uniform exposure of the order of 50 nSv/hr to 100 mSv/hr. In the second system discussed, the degree of gamma compensation achieved is equal to those dictated by the statistical nature of the uncertainties associated with the subtraction of background from the source data. These two methods can be very effectively employed depending on the application requirement. A minimum detection level equivalent to 0.37 Bq/cdm 2 has been achieved in both these cases

  9. Knowledge and adoption of solar home systems in rural Nicaragua

    International Nuclear Information System (INIS)

    Rebane, Kaja L.; Barham, Bradford L.

    2011-01-01

    Solar home systems (SHSs) are a promising electrification option for many households in the developing world. In most countries SHSs are at an early stage of dissemination, and thus face a hurdle common to many emerging alternative energy technologies: many people do not know enough about them to decide whether to adopt one or not. This study uses survey data collected in Nicaragua to investigate characteristics that predict the knowledge and adoption of SHSs among the rural population. First, a series of probit models is used to model the determinants of four measures of SHS knowledge. Next, a biprobit model with sample selection is employed to investigate the factors that predict SHS adoption, conditional on having sufficient knowledge to make an adoption decision. Comparison of the biprobit formulation to a standard probit model of adoption affirms its value. This study identifies multiple determinants of SHS knowledge and adoption, offers several practical recommendations to project planners, and provides an analytical framework for future work in this policy-relevant area. - Research highlights: → Solar home systems (SHSs) are a promising rural electrification option in the developing world. → As with many emerging renewable energy technologies, lack of knowledge may limit SHS adoption. → We use probit models to investigate the determinants of SHS knowledge in rural Nicaragua. → We also employ a biprobit model linking the determinants of knowledge and adoption. → We find that in analyzing SHS adoption, accounting for sample selection based on knowledge is key.

  10. A Domestic Microgrid with Optimized Home Energy Management System

    Directory of Open Access Journals (Sweden)

    Zafar Iqbal

    2018-04-01

    Full Text Available Microgrid is a community-based power generation and distribution system that interconnects smart homes with renewable energy sources (RESs. Microgrid efficiently and economically generates power for electricity consumers and operates in both islanded and grid-connected modes. In this study, we proposed optimization schemes for reducing electricity cost and minimizing peak to average ratio (PAR with maximum user comfort (UC in a smart home. We considered a grid-connected microgrid for electricity generation which consists of wind turbine and photovoltaic (PV panel. First, the problem was mathematically formulated through multiple knapsack problem (MKP then solved by existing heuristic techniques: grey wolf optimization (GWO, binary particle swarm optimization (BPSO, genetic algorithm (GA and wind-driven optimization (WDO. Furthermore, we also proposed three hybrid schemes for electric cost and PAR reduction: (1 hybrid of GA and WDO named WDGA; (2 hybrid of WDO and GWO named WDGWO; and (3 WBPSO, which is the hybrid of BPSO and WDO. In addition, a battery bank system (BBS was also integrated to make our proposed schemes more cost-efficient and reliable, and to ensure stable grid operation. Finally, simulations were performed to verify our proposed schemes. Results show that our proposed scheme efficiently minimizes the electricity cost and PAR. Moreover, our proposed techniques, WDGA, WDGWO and WBPSO, outperform the existing heuristic techniques.

  11. Pilot study for home monitoring of cough capacity in amyotrophic lateral sclerosis: A case series

    Directory of Open Access Journals (Sweden)

    M. Paneroni

    2014-07-01

    Full Text Available Background: Cough capacity derangement is associated with a high risk of pulmonary complications in amyotrophic lateral sclerosis patients when cough assistance is not routinely performed at home. The primary aim of this study was to evaluate the feasibility of a long-term home based daily self-monitoring cough capacity. Methods: Eighteen subjects were enrolled in a 9-month study at home. Changes in peak cough expiratory flow, oxygen saturation, respiratory discomfort and incidence of respiratory deterioration events were evaluated. In subjects presenting respiratory deterioration events, decline in the abovementioned respiratory variables was evaluated (#NCT00613899. Results: During an average follow-up of 125 ± 102 days, a total of 1175 measures were performed on 12 subjects. Mean compliance to proposed evaluations was 37 ± 32% which worsened over time. Peak cough expiratory flow decreased by 15.08 ± 32.43 L/min monthly. Five subjects reported 6 episodes of respiratory deterioration events, after a mean period of 136 ± 108 days. They had poor respiratory function and more years of disease. There was no difference in peak cough expiratory flow and its decline whether subjects presented respiratory deterioration events or not. In 4 subjects the respiratory discomfort score significantly worsened after respiratory deterioration events from 3.0 ± 1.41 to 4.25 ± 1.71. Conclusion: Daily self-monitoring of peak cough expiratory flow, oxygen saturation and respiratory discomfort seems difficult to obtain because of poor adherence to measures; this protocol does not seem to add anything to current practice of advising on clinical derangements. Confirmatory larger studies are necessary. Resumo: Antecedentes: A disfunção na capacidade de tosse está associada a um elevado risco de complicações pulmonares nos doentes com esclerose lateral amiotrófica, quando a sua monitorização não é realizada rotineiramente no domicílio. O

  12. Uranium concentration monitor manual: 2300 system

    International Nuclear Information System (INIS)

    Russo, P.A.; Sprinkle, J.K. Jr.; Stephens, M.M.

    1985-04-01

    This manual describes the design, operation, and procedures for measurement control for the automated uranium concentration monitor on the 2300 solvent extraction system at the Oak Ridge Y-12 Plant. The nonintrusive monitor provides a near-real time readout of uranium concentration at two locations simultaneously in the solvent extraction system for process monitoring and control. Detectors installed at the top of the extraction column and at the bottom of the backwash column acquire spectra of gamma rays from the solvent extraction solutions in the columns. Pulse-height analysis of these spectra gives the concentration of uranium in the organic product of the extraction column and in the aqueous product of the solvent extraction system. The visual readouts of concentrations for process monitoring are updated every 2 min for both detection systems. Simultaneously, the concentration results are shipped to a remote computer that has been installed by Y-12 to demonstrate automatic control of the solvent extraction system based on input of near-real time process operation information. 8 refs., 13 figs., 4 tabs

  13. An interactive beam position monitor system simulator

    International Nuclear Information System (INIS)

    Ryan, W.A.; Shea, T.J.

    1993-03-01

    A system simulator has been implemented to aid the development of the RHIC position monitor system. Based on the LabVIEW software package by National Instruments, this simulator allows engineers and technicians to interactively explore the parameter space of a system during the design phase. Adjustable parameters are divided into three categories: beam, pickup, and electronics. The simulator uses these parameters in simple formulas to produce results in both time-domain and frequencydomain. During the prototyping phase, these simulated results can be compared to test data acquired with the same software package. The RHIC position monitor system is presented as an example, but the software is applicable to several other systems as well

  14. Radiation monitoring system based on Internet

    International Nuclear Information System (INIS)

    Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.

    2001-01-01

    This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)

  15. Environmental radiation monitoring system with GPS (global positioning system)

    International Nuclear Information System (INIS)

    Komoto, Itsuro

    2000-01-01

    This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)

  16. FFTF fission gas monitor computer system

    International Nuclear Information System (INIS)

    Hubbard, J.A.

    1987-01-01

    The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be controlled by the computer, allowing the system to provide rapid system self tests and operational performance reports

  17. The dynamic state monitoring of bearings system

    Directory of Open Access Journals (Sweden)

    Marek Krynke

    2015-03-01

    Full Text Available The article discusses the methods of dynamic state monitoring of bearings system. A vibration signal contains important technical information about the machine condition and is currently the most frequently used in diagnostic bearings systems. One of the main ad-vantages of machine condition monitoring is identifying the cause of failure of the bearings and taking preventative measures, otherwise the operation of such a machine will lead to frequent replacement of the bearings. Monitoring changes in the course of the operation of machin-ery repair strategies allows keeping the conditioned state of dynamic failure conditioned preventive repairs and repairs after-failure time. In addition, the paper also presents the fundamental causes of bearing failure and identifies mechanisms related to the creation of any type of damage.

  18. Design of Simple Landslide Monitoring System

    Science.gov (United States)

    Meng, Qingjia; Cai, Lingling

    2018-01-01

    The simple landslide monitoring system is mainly designed for slope, collapse body and surface crack. In the harsh environment, the dynamic displacement data of the disaster body is transmitted to the terminal acquisition system in real time. The main body of the system adopt is PIC32MX795F512. This chip is to realize low power design, wakes the system up through the clock chip, and turns on the switching power supply at set time, which makes the wireless transmission module running during the interval to ensure the maximum battery consumption, so that the system can be stable long term work.

  19. Home blood pressure monitoring and self-titration of antihypertensive medications: Proposed patient selection criteria.

    Science.gov (United States)

    Hill, James R

    2016-05-01

    Recent studies have demonstrated that home blood pressure monitoring (HBPM), coupled with self-titration of medications is a viable intervention to control hypertension. There are currently no established criteria to evaluate patients for inclusion in such a program. The purpose of this discussion is to propose criteria for determining if a patient is appropriate to participate in a program of HBPM and self-titration. Inclusion criteria for two self-titration trials were examined, and additional factors in clinical practice were identified and discussed. Additional selection criteria were proposed to support the decision to enroll a patient in an antihypertensive self-titration program. Inclusion criteria from self-titration trials provide a reasonable starting point for choosing appropriate patients in clinical practice, but additional research is necessary. Adaptation of these criteria and consideration of the identified factors can be used to develop decision support instruments. Such instruments should be evaluated for effectiveness and reliability prior to use in clinical practice. HBPM combined with self-titration is an effective patient-centered approach for hypertension management. Decision support instruments to determine appropriate patients are necessary for safe and effective use in clinical practice. ©2015 American Association of Nurse Practitioners.

  20. Using a home blood pressure monitor: do accompanying instructional materials meet low literacy guidelines?

    Science.gov (United States)

    Wallace, Lorraine S; Keenum, Amy J

    2008-08-01

    To evaluate the readability and related features of English language Quick Reference Guides (QRGs) and User Manuals (UMs) accompanying home blood pressure monitors (HBPMs). We evaluated QRGs and UMs for 22 HBPMs [arm (n=12); wrist (n=10)]. Using established criteria, we evaluated reading grade level, language availability, dimensions, text point size, use of illustrations, layout/formatting characteristics, and emphasis of key points of English-language patient instructions accompanying HBPMs. Readability was calculated using McLaughlin's Simplified Measure of Gobbledygoop. Items from the Suitability of Materials Assessment and User-Friendliness Tool were used to assess various layout features. Simplified Measure of Gobbledygoop scores of both QRGs (mean+/-SD=9.1+/-0.8) and UMs (9.3+/-0.8) ranged from 8th to 10th grade. QRGs and UMs presented steps in chronological order, used active voice throughout, avoided use of specialty fonts, focused on need to know, and used realistic illustrations. Seven sets of instructions included all seven key points related to proper HPBM use, whereas three sets of instructions included less than or equal to three key points (mean=4.8+/-1.9). Although most QRGs and UMs met at least some recommended low-literacy formatting guidelines, all instructional materials should be developed and tested to meet the needs of the patient population at large. Key points related to proper HBPM use should not only be included within these instructions, but highlighted to emphasize their importance.