WorldWideScience

Sample records for holter monitoring showed

  1. ECG Holter monitor with alert system and mobile application

    Science.gov (United States)

    Teron, Abigail C.; Rivera, Pedro A.; Goenaga, Miguel A.

    2016-05-01

    This paper proposes a new approach on the Holter monitor by creating a portable Electrocardiogram (ECG) Holter monitor that will alert the user by detecting abnormal heart beats using a digital signal processing software. The alarm will be triggered when the patient experiences arrhythmias such as bradycardia and tachycardia. The equipment is simple, comfortable and small in size that fit in the hand. It can be used at any time and any moment by placing three leads to the person's chest which is connected to an electronic circuit. The ECG data will be transmitted via Bluetooth to the memory of a selected mobile phone using an application that will store the collected data for up to 24 hrs. The arrhythmia is identified by comparing the reference signals with the user's signal. The diagnostic results demonstrate that the ECG Holter monitor alerts the user when an arrhythmia is detected thru the Holter monitor and mobile application.

  2. NORMAN HOLTER AND HIS METHOD OF REMOTE CARDIOLOGIC MONITORING. CASE HISTORY

    Directory of Open Access Journals (Sweden)

    A. A. Rassadina

    2013-01-01

    Full Text Available This publication is devoted to the personality and creative designs of uncommon American scientist, the engineer and the inventor – Norman Jefferis «Jeff» Holter. Norman Jefferis Holter introduced the terminology of «nuclear medicine» for the name of the new at that time area which associated with employment of the achievements of the nuclear physics in the medical goals. Also he is the author of ambulatory cardiological monitoring.

  3. Continuous stroke unit electrocardiographic monitoring versus 24-hour Holter electrocardiography for detection of paroxysmal atrial fibrillation after stroke.

    Science.gov (United States)

    Rizos, Timolaos; Güntner, Janina; Jenetzky, Ekkehart; Marquardt, Lars; Reichardt, Christine; Becker, Rüdiger; Reinhardt, Roland; Hepp, Thomas; Kirchhof, Paulus; Aleynichenko, Elena; Ringleb, Peter; Hacke, Werner; Veltkamp, Roland

    2012-10-01

    Cardioembolism in paroxysmal atrial fibrillation (pxAF) is a frequent cause of ischemic stroke. Sensitive detection of pxAF after stroke is crucial for adequate secondary stroke prevention; the optimal diagnostic modality to detect pxAF on stroke units is unknown. We compared 24-hour Holter electrocardiography (ECG) with continuous stroke unit ECG monitoring (CEM) for pxAF detection. Patients with acute ischemic stroke or transient ischemic attack were prospectively enrolled. After a 12-channel ECG on admission, all patients received 24-hour Holter ECG and CEM. Additionally, ECG monitoring data underwent automated analysis using dedicated software to identify pxAF. Patients with a history of atrial fibrillation or with atrial fibrillation on the admission ECG were excluded. Four hundred ninety-six patients (median age, 69 years; 61.5% male) fulfilled all inclusion criteria (ischemic stroke: 80.4%; transient ischemic attack: 19.6%). Median stroke unit stay lasted 88.8 hours (interquartile range, 65.0-122.0). ECG data for automated CEM analysis were available for a median time of 64.0 hours (43.0-89.8). Paroxysmal AF was documented in 41 of 496 patients (8.3%). Of these, Holter detected pxAF in 34.1%; CEM in 65.9%; and automated CEM in 92.7%. CEM and automated CEM detected significantly more patients with pxAF than Holter (Pstroke on stroke units compared with 24-hour Holter ECG. The comparative usefulness of prolonged or repetitive Holter ECG recordings requires further evaluation.

  4. Holter registers and metabolic syndrome

    Science.gov (United States)

    Muñoz-Diosdado, A.; Ramírez-Hernández, L.; Aguilar-Molina, A. M.; Zamora-Justo, J. A.; Gutiérrez-Calleja, R. A.; Virgilio-González, C. D.

    2014-11-01

    There is a relationship between the state of the cardiovascular system and metabolic syndrome (MS). A way to diagnose the heart state of a person is to monitor the electrical activity of the heart using a 24 hours Holter monitor. Scanned ECG signal can be analyzed beat-by-beat by algorithms that separate normal of abnormal heartbeats. If the percentage of abnormal heartbeats is too high it could be argued that the patient has heart problems. We have algorithms that can not only identify the abnormal heartbeats, but they can also classify them, so we classified and counted abnormal heartbeats in patients with MS and subjects without MS. Most of our patients have large waist circumference, high triglycerides and high levels of LDL (high-density lipoprotein) cholesterol although some of them have high blood pressure. We enrolled adult patients with MS free of diabetes in a four month lifestyle intervention program including diet and physical aerobic exercise, and compared with healthy controls. We made an initial registration with a Holter, and 24 hours ECG signal is analyzed to identify and classify the different types of heartbeats. The patients then begin with diet or exercise (at least half an hour daily). Periodically Holter records were taken up and we describe the evolution in time of the number and type of abnormal heartbeats. Results show that the percentage of abnormal heartbeats decreases over time, in some cases the decline is very significant, and almost a reduction to half or less of abnormal heartbeats after several months since the patients changed their eating or physical activity habits.

  5. Relationship between 24- hour Holter variables, chest discomfort and syncope: Does age matter?

    Directory of Open Access Journals (Sweden)

    Samir Kanti Saha

    2013-01-01

    Full Text Available One hundred and forty four ambulatory, non-emergent human subjects from 20-88 years of age were investigated following routine 24 hour Holter monitoring referred by primary and tertiary care centers primarily for evaluation of palpitations and syncope. The patients were grouped into 3 different age categories: A 20-59 years of age (16%, B 60-69 years of age (26.4% and C > 70 years of age (57.6%. Heart rate profile, RR intervals, symptoms, frequency of premature supra ventricular and ventricular complexes were registered. The data show that though the occurrence and frequency of premature atrial and ventricular contractions over a period of 24 hours did not differ between the groups, the younger subjects documented more subjective discomforts during the Holter monitoring. Extra-systoles in excess of 1000 beats / 24 hour occured incessantly throughout the registration. Patients with syncope and those without did not differ as regards the Holter variables. However, subjects with atrial fibrillation had acceptable rate control and had significantly lower incidence of syncope than those with sinus rhythm. The findings suggest that in a county setting, Holter monitoring for evaluation of syncope may not be the first hand mode of investigation in a non emergent setting. On the contrary, the modality appears to be valuable for monitoring patients with atrial fibrillation. Even mild symptoms in the elderly population may warrant closer clinical follow up to prevent cardiac events and/or syncope leading to serious physical injury.

  6. Smart blood pressure holter.

    Science.gov (United States)

    İlhan, İlhan

    2018-03-01

    In this study, a wireless blood pressure holter that can be used with smart mobile devices was developed. The developed blood pressure holter consists of two parts, which are a smart mobile device and a cuff. The smart mobile device is used as a recording, control and display device through a developed interface, while the cuff was designed to take measurements from the arm. Resistor-Capacitor (RC) and digital filters were used on the cuff that communicates with the smart mobile device via Bluetooth. The blood pressure was estimated using the Simple Hill Climbing Algorithm (HCA). It is possible to measure instantaneous or programmable blood pressure and heart rate values at certain intervals using this holter. The test was conducted with 30 individuals at different ages with the guidance of a specialist health personnel. The results showed that an accuracy at 93.89% and 91.95% rates could be obtained for systolic and diastolic pressure values, respectively, when compared with those obtained using a traditional sphygmomanometer. The accuracy level for the heart rate was measured as 97.66%. Furthermore, this device was tested day and night in the holter mode in terms of working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The test results were evaluated separately in terms of measurement accuracy, working time, the continuity of the Bluetooth connection and the reliability of the measurement results. The measurement accuracy for systolic, diastolic blood pressure and heart rate values was obtained as 93.89%, 91.95% and 97.66%, respectively. The maximum number of measurements which can be conducted with four 1000 mA alkaline batteries at 20 min intervals was found approximately 79 (little more than 24 h). In addition, it was determined that the continuity of the Bluetooth connection and the reliability of the measurement results were automatically achieved through the features in the interface developed for the

  7. A portable ECG monitoring device with Bluetooth and Holter capabilities for telemedicine applications.

    Science.gov (United States)

    Lucani, Daniel; Cataldo, Giancarlos; Cruz, Julio; Villegas, Guillermo; Wong, Sara

    2006-01-01

    A prototype of a portable ECG-monitoring device has been developed for clinical and non-clinical environments as part of a telemedicine system to provide remote and continuous surveillance of patients. The device can acquire, store and/or transmit ECG signals to computer-based platforms or specially configured access points (AP) with Intranet/Internet capabilities in order to reach remote monitoring stations. Acquired data can be stored in a flash memory card in FAT16 format for later recovery, or transmitted via Bluetooth or USB to a local station or AP. This data acquisition module (DAM) operates in two modes: Holter and on-line transmission.

  8. The relationship between ST segment deviation projected to the front of the chest during exercise and simultaneous Holter monitoring

    DEFF Research Database (Denmark)

    Egstrup, K

    1988-01-01

    were placed to correspond to CM5 and an aVF-like lead. In 36 patients, ST segment changes were found with both Holter and the 12-lead precordial electrocardiogram, while in 12 patients no ischaemic changes were detected by either method. Thus the results of the two methods concurred in 48 of 50 patient...... (96%). The magnitude of the ischaemic change was similar in 24 of 36 patients (67%), while the Holter system underestimated the ischaemic change by 0.5-2.0 mm in 12 patients. When the maximal ST segment deviation in V5 was compared with CM5, the deviations with both systems were identical in all...... but one patient in whom a difference of 0.5 mm was found. The use of a Holter lead resembling a VF identified maximal ST segment change on only one occasion, and in only four patients was an ST segment change of 1 mm noted. In conclusion, ambulatory monitoring utilizing only CM5 seems to detect most...

  9. Holter-electrocardiogram-monitoring in patients with acute ischaemic stroke (Find-AFRANDOMISED): an open-label randomised controlled trial.

    Science.gov (United States)

    Wachter, Rolf; Gröschel, Klaus; Gelbrich, Götz; Hamann, Gerhard F; Kermer, Pawel; Liman, Jan; Seegers, Joachim; Wasser, Katrin; Schulte, Anna; Jürries, Falko; Messerschmid, Anna; Behnke, Nico; Gröschel, Sonja; Uphaus, Timo; Grings, Anne; Ibis, Tugba; Klimpe, Sven; Wagner-Heck, Michaela; Arnold, Magdalena; Protsenko, Evgeny; Heuschmann, Peter U; Conen, David; Weber-Krüger, Mark

    2017-04-01

    Atrial fibrillation is a major risk factor for recurrent ischaemic stroke, but often remains undiagnosed in patients who have had an acute ischaemic stroke. Enhanced and prolonged Holter-electrocardiogram-monitoring might increase detection of atrial fibrillation. We therefore investigated whether enhanced and prolonged rhythm monitoring was better for detection of atrial fibrillation than standard care procedures in patients with acute ischaemic stroke. Find-AF randomised is an open-label randomised study done at four centres in Germany. We recruited patients with acute ischaemic stroke (symptoms for 7 days or less) aged 60 years or older presenting with sinus rhythm and without history of atrial fibrillation. Patients were included irrespective of the suspected cause of stroke, unless they had a severe ipsilateral carotid or intracranial artery stenosis, which were the exclusion criteria. We used a computer-generated allocation sequence to randomly assign patients in a 1:1 ratio with permuted block sizes of 2, 4, 6, and 8, stratified by centre, to enhanced and prolonged monitoring (ie, 10-day Holter-electrocardiogram [ECG]-monitoring at baseline, and at 3 months and 6 months of follow-up) or standard care procedures (ie, at least 24 h of rhythm monitoring). Participants and study physicians were not masked to group assignment, but the expert committees that adjudicated endpoints were. The primary endpoint was the occurrence of atrial fibrillation or atrial flutter (30 sec or longer) within 6 months after randomisation and before stroke recurrence. Because Holter ECG is a widely used procedure and not known to harm patients, we chose not to assess safety in detail. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01855035. Between May 8, 2013, and Aug 31, 2014, we recruited 398 patients. 200 patients were randomly assigned to the enhanced and prolonged monitoring group and 198 to the standard care group. After 6

  10. 24-Hour Holter Monitoring at the Lagos State University Teaching ...

    African Journals Online (AJOL)

    However, only a minority of such patients have documented and confirmed clinically significant tachyarrhythmias in this study. A subsequent larger prospective study would shed more light on this subject. Key Words: Electrocardiogram (ECG), 24-hour Holter, Heart Rate variability. Paroxysmal tachyarrhythmias.

  11. Characteristics and prognostic importance of ST-segment elevation on Holter monitoring early after acute myocardial infarction

    DEFF Research Database (Denmark)

    Mickley, H; Nielsen, J R; Berning, J

    1995-01-01

    The correlation between episodes of ST-segment elevation on Holter monitoring, clinical characteristics, left ventricular function, exercise testing, and long-term prognosis was determined in 123 consecutive patients 55 +/- 8 years old (mean +/- SD) with a first acute myocardial infarction (AMI...... +/- 11% (p = 0.0001). All episodes of ST-segment elevation were asymptomatic and did not correlate with different indicators of myocardial ischemia. Indeed, exercise-induced ST-segment depression was more prevalent in group 2 than in group 1: 57 vs 18% (p

  12. Serial Holter ST-segment monitoring after first acute myocardial infarction. Prevalence, variability, and long-term prognostic importance of transient myocardial ischemia

    DEFF Research Database (Denmark)

    Mickley, H; Nielsen, J R; Berning, J

    1998-01-01

    Based on serial Holter monitoring performed 7 times within 3 years after a first acute myocardial infarction, we assessed the prevalence, variability and long-term clinical importance of transient myocardial ischemia (TMI) defined as episodes of ambulatory ST-segment depression. In all, 121...... consecutive male patients variability was found within and between patients...

  13. Finding atrial fibrillation in stroke patients: Randomized evaluation of enhanced and prolonged Holter monitoring--Find-AF(RANDOMISED) --rationale and design.

    Science.gov (United States)

    Weber-Krüger, Mark; Gelbrich, Götz; Stahrenberg, Raoul; Liman, Jan; Kermer, Pawel; Hamann, Gerhard F; Seegers, Joachim; Gröschel, Klaus; Wachter, Rolf

    2014-10-01

    Detecting paroxysmal atrial fibrillation (AF) in patients with ischemic strokes presenting in sinus rhythm is challenging because episodes are often short, occur randomly, and are frequently asymptomatic. If AF is detected, recurrent thromboembolism can be prevented efficiently by oral anticoagulation. Numerous uncontrolled studies using various electrocardiogram (ECG) devices have established that prolonged ECG monitoring increases the yield of AF detection, but most established procedures are time-consuming and costly. The few randomized trials are mostly limited to cryptogenic strokes. The optimal method, duration, and patient selection remain unclear. Repeated prolonged continuous Holter ECG monitoring to detect paroxysmal AF within an unspecific stroke population may prove to be a widely applicable, effective secondary prevention strategy. Find-AFRANDOMISED is a randomized and controlled prospective multicenter trial. Four hundred patients 60 years or older with manifest (symptoms ≥24 hours or acute computed tomography/magnetic resonance imaging lesion) and acute (symptoms ≤7 days) ischemic strokes will be included at 4 certified stroke centers in Germany. Those with previously diagnosed AF/flutter, indications/contraindications for oral anticoagulation, or obvious causative blood vessel pathologies will be excluded. Patients will be randomized 1:1 to either enhanced and prolonged Holter ECG monitoring (10 days at baseline and after 3 and 6 months) or standard of care (≥24-hour continuous ECG monitoring, according to current stroke guidelines). All patients will be followed up for at least 12 months. The primary end point is newly detected AF (≥30 seconds) after 6 months, confirmed by an independent adjudication committee. We plan to complete recruitment in autumn 2014. First results can be expected by spring 2016. Copyright © 2014 Mosby, Inc. All rights reserved.

  14. Prognosis in medically stabilized unstable angina: Early Holter ST-segment monitoring compared with predischarge exercise thallium tomography

    International Nuclear Information System (INIS)

    Marmur, J.D.; Freeman, M.R.; Langer, A.; Armstrong, P.W.

    1990-01-01

    The objective of this study was to assess the relative value of invasive and noninvasive predictors of outcome in patients after unstable angina. Fifty-four patients with unstable angina who had 6-month follow-up after stabilization on medical therapy were evaluated. We prospectively compared 24-hour Holter ST-segment monitoring at admission, quantitative exercise thallium tomography, and cardiac catheterization 5 +/- 2 days after admission and analyzed their value for predicting a cardiac event in patients with unstable angina within 6 months. When patients with a favorable outcome (n = 40) were compared with patients with an unfavorable outcome (n = 11) no statistical difference was found in duration of ST shift of 1 mm or more on Holter monitoring (51 +/- 119 min compared with 37 +/- 43 min), exercise duration by the standard Bruce protocol (8.0 +/- 3.6 min compared with 7.9 +/- 3.1 min), exercise-induced ST depression (0.6 +/- 0.9 mm compared with 1.0 +/- 1.0 mm), and contrast left ventricular ejection fraction (70% +/- 10% compared with 69% +/- 15%). Patients with a favorable outcome were distinguished from those with an unfavorable outcome by a higher maximum rate-pressure product (24 x 10(3) +/- 6 x 10(3) compared with 18 x 10(3) +/- 7 x 10(3), P = 0.0025), smaller size of the reversible scintigraphic perfusion defect expressed as a percentage of total myocardium imaged (6% +/- 11% compared with 17% +/- 18%, P = 0.05) and a smaller number of vessels with stenosis of 50% or more (1.1 +/- 1.2 compared with 2.1 +/- 1.0, P = 0.01). On multiple logistic regression analysis, a history of previous myocardial infarction was the most powerful predictor of outcome. In patients without myocardial infarction, reversible exercise thallium perfusion defect size was the only predictor

  15. Avaliação perioperatória através do holter em pacientes idosos submetidos à prostatectomia Evaluación perioperatoria mediante el holter en pacientes adultos mayores sometidos a prostatectomia Peri-operative evaluation by holter in elderly patients submitted to prostatectomy

    Directory of Open Access Journals (Sweden)

    Thais Orrico de Brito Cançado

    2009-10-01

    this protocol, we used continuous ambulatory monitoring (Holter System, in the perioperative period of 30 patients, aged over 65 years, who underwent transurethral resection of the prostate under spinal anesthesia. RESULTS: In the preoperative and transoperative evaluations, frequent complex ventricular and supraventricular arrhythmias were observed, and also ischemic changes. In the transoperative recording, the patients who had ischemic episodes were the same ones who showed total ischemic burden of more than 60 minutes in the preoperative recording. CONCLUSION: Ambulatory monitoring is not regarded as an appropriate procedure for the screening of myocardial ischemia, due to the characteristics and technical limitations of the method, especially in populations with a low prevalence of coronary disease. In this cross-sectional and observational study, we concluded that the Holter recordings provided additional information which could not be obtained by conventional electrocardiogram.

  16. Design of a Holter for Electroencephalography and Polysomnography

    International Nuclear Information System (INIS)

    Martin Gonzalez, Francisco; Velarde Reyes, Ernesto

    2009-01-01

    This paper presents the design of a 40 digital channels Holter for ambulatory studies of electroencephalography(EEG) and polisomnography (PSG), specially for epilepsy and sleep disorders. It includes a revision of the market and technologies used in such equipment. The requirements of design are established, and solutions are presented. It shows a functional diagram of the system including technologies like wireless communication, reading and writing in USB flash devices and a new amplifier design with dynamic compensation of direct current polarization

  17. The evolution of ambulatory ECG monitoring.

    Science.gov (United States)

    Kennedy, Harold L

    2013-01-01

    Ambulatory Holter electrocardiographic (ECG) monitoring has undergone continuous technological evolution since its invention and development in the 1950s era. With commercial introduction in 1963, there has been an evolution of Holter recorders from 1 channel to 12 channel recorders with increasingly smaller storage media, and there has evolved Holter analysis systems employing increasingly technologically advanced electronics providing a myriad of data displays. This evolution of smaller physical instruments with increasing technological capacity has characterized the development of electronics over the past 50 years. Currently the technology has been focused upon the conventional continuous 24 to 48 hour ambulatory ECG examination, and conventional extended ambulatory monitoring strategies for infrequent to rare arrhythmic events. However, the emergence of the Internet, Wi-Fi, cellular networks, and broad-band transmission has positioned these modalities at the doorway of the digital world. This has led to an adoption of more cost-effective strategies to these conventional methods of performing the examination. As a result, the emergence of the mobile smartphone coupled with this digital capacity is leading to the recent development of Holter smartphone applications. The potential of point-of-care applications utilizing the Holter smartphone and a vast array of new non-invasive sensors is evident in the not too distant future. The Holter smartphone is anticipated to contribute significantly in the future to the field of global health. © 2013.

  18. Circadian variation in QT dispersion determined from a 12-lead Holter recording

    DEFF Research Database (Denmark)

    Hansen, Stig; Rasmussen, Verner; Larsen, Klaus

    2007-01-01

    Background: QT dispersion is considered to reflect inhomogeneity of myocardial repolarization. Method: The circadian variation of QT interval dispersion was examined in 95 healthy subjects using 24-hour Holter monitoring. Three different methods of lead selection were applied: all 12 leads (QTdisp...... circadian variation using mean values of QTdisp 12, QTdisp 6, or QTdisp 2 obtained every hour, every 2, or every 4 hours, except in QTdisp 6, which demonstrated a significant circadian variation (P ... a significant circadian variation in QTdisp 12 and QTdisp 6 (P circadian variation was seen in QTdisp 2. A subdivision into 10-year age groups revealed that subjects at age >50 years had a significant circadian variation in QTdisp 12 and QTdisp 6, but not in QTdisp 2. Only in males...

  19. Heritability of ECG Biomarkers in the Netherlands Twin Registry Measured from Holter ECGs.

    Directory of Open Access Journals (Sweden)

    Emily C Hodkinson

    2016-04-01

    Full Text Available INTRODUCTIONThe resting ECG is the most commonly used tool to assess cardiac electrophysiology. Previous studies have estimated heritability of ECG parameters based on these snapshots of the cardiac electrical activity. In this study we set out to determine whether analysis of heart rate specific data from Holter ECGs allows more complete assessment of the heritability of ECG parameters.METHODS and RESULTSHolter ECGs were recorded from 221 twin pairs and analyzed using a multi-parameter beat binning approach. Heart rate dependent estimates of heritability for QRS duration, QT interval, Tpeak–Tend and Theight were calculated using structural equation modelling. QRS duration is largely determined by environmental factors whereas repolarization is primarily genetically determined. Heritability estimates of both QT interval and Theight were significantly higher when measured from Holter compared to resting ECGs and the heritability estimate of each was heart rate dependent. Analysis of the genetic contribution to correlation between repolarization parameters demonstrated that covariance of individual ECG parameters at different heart rates overlap but at each specific heart rate there was relatively little overlap in the genetic determinants of the different repolarization parameters.CONCLUSIONSHere we present the first study of heritability of repolarization parameters measured from Holter ECGs. Our data demonstrate that higher heritability can be estimated from the Holter than the resting ECG and reveals rate dependence in the genetic – environmental determinants of the ECG that has not previously been tractable. Future applications include deeper dissection of the ECG of participants with inherited cardiac electrical disease.

  20. [Atypical sinus node dysfunction. Usefulness of implantable Holter. A case report].

    Science.gov (United States)

    Martí Almor, J; Delclòs Urgell, J; Bruguera Cortada, J

    2001-12-01

    We present an 84 year-old female patient with repeated syncopes/presyncopes in the last nine years. All diagnosis tests were negative, including ECG, 24-hour Holter, tilt table test and EP study. Therefore, a subcutaneous insertable loop recorder was implanted (Reveal). The recording of three episodes showed the association of presyncope with the onset of atrial fibrilation and, in two syncopes, with an atrial pause between AF episodes. Probably an abnormal prolonged sinus node recovery time (more than 6 s) allowed AF to restart before the sinus rhythm.

  1. Cuff inflation during ambulatory blood pressure monitoring and heart rate

    Directory of Open Access Journals (Sweden)

    Mia Skov-Madsen

    2008-11-01

    Full Text Available Mia Skov-Madsen, My Svensson, Jeppe Hagstrup ChristensenDepartment of Nephrology, Aarhus University Hospital, Aalborg, DenmarkIntroduction: Twenty four-hour ambulatory blood pressure monitoring is a clinically validated procedure in evaluation of blood pressure (BP. We hypothesised that the discomfort during cuff inflation would increase the heart rate (HR measured with 24-h ambulatory BP monitoring compared to a following HR measurement with a 24-h Holter monitor.Methods: The study population (n = 56 were recruited from the outpatient’s clinic at the Department of Nephrology, Aalborg Hospital, Aarhus University Hospital at Aalborg, Denmark. All the patients had chronic kidney disease (CKD. We compared HR measured with a 24-h Holter monitor with a following HR measured by a 24-h ambulatory BP monitoring.Results: We found a highly significant correlation between the HR measured with the Holter monitor and HR measured with 24-h ambulatory blood pressure monitoring (r = 0.77, p < 0.001. Using the Bland-Altman plot, the mean difference in HR was only 0.5 beat/min during 24 hours with acceptable limits of agreement for both high and low HR levels. Dividing the patients into groups according to betablocker treatment, body mass index, age, sex, angiotensin-converting enzyme inhibitor treatment, statins treatment, diuretic treatment, or calcium channel blocker treatment revealed similar results as described above.Conclusion: The results indicate that the discomfort induced by cuff inflation during 24-h ambulatory BP monitoring does not increase HR. Thus, 24-h ambulatory BP monitoring may be a reliable measurement of the BP among people with CKD.Keywords: ambulatory blood pressure monitoring, Holter monitoring, heart rate, chronic kidney disease, hypertension

  2. Yield of atrial fibrillation detection with Textile Wearable Holter from the acute phase of stroke: Pilot study of Crypto-AF registry.

    Science.gov (United States)

    Pagola, Jorge; Juega, Jesus; Francisco-Pascual, Jaume; Moya, Angel; Sanchis, Mireia; Bustamante, Alejandro; Penalba, Anna; Usero, Maria; Cortijo, Elisa; Arenillas, Juan F; Calleja, Ana I; Sandin-Fuentes, Maria; Rubio, Jeronimo; Mancha, Fernando; Escudero-Martinez, Irene; Moniche, Francisco; de Torres, Reyes; Pérez-Sánchez, Soledad; González-Matos, Carlos E; Vega, Ángela; Pedrote, Alonso A; Arana-Rueda, Eduardo; Montaner, Joan; Molina, Carlos A

    2018-01-15

    We describe the feasibility of monitoring with a Textile Wearable Holter (TWH) in patients included in Crypto AF registry. We monitored cryptogenic stroke patients from stroke onset (<3days) continuously during 28days. We employed a TWH composed by a garment and a recorder. We compared two garments (Lead and Vest) to assess rate of undiagnosed Atrial Fibrillation (AF) detection, monitoring compliance, comfortability (1 to 5 points), skin lesions, and time analyzed. We describe the timing of AF detection in three periods (0-3, 4-15 and 16-28days). The rate of undiagnosed AF detection with TWH was 21.9% (32 out of 146 patients who completed the monitoring). Global time compliance was 90% of the time expected (583/644h). The level of comfortability was 4 points (IQR 3-5). We detected reversible skin lesions in 5.47% (8/146). The comfortability was similar but time compliance (in hours) was longer in Vest group 591 (IQR [521-639]) vs. Lead 566 (IQR [397-620]) (p=0.025). Also, time analyzed was more prolonged in Vest group 497 (IQR [419-557]) vs. Lead (336h (IQR [140-520]) (p=0.001)). The incidence of AF increases from 5.6% (at 3days) to 17.5% (at 15th day) and up to 20.9% (at 28th day). The percentage of AF episodes detected only in each period was 12.5% (0-3days); 21.7% (4-15days) and 19% (16-28days). 28days Holter monitoring from the acute phase of the stroke was feasible with TWH. Following our protocol, only five patients were needed to screen to detected one case of AF. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. On the Beat Detection Performance in Long-Term ECG Monitoring Scenarios

    Directory of Open Access Journals (Sweden)

    Francisco-Manuel Melgarejo-Meseguer

    2018-05-01

    Full Text Available Despite the wide literature on R-wave detection algorithms for ECG Holter recordings, the long-term monitoring applications are bringing new requirements, and it is not clear that the existing methods can be straightforwardly used in those scenarios. Our aim in this work was twofold: First, we scrutinized the scope and limitations of existing methods for Holter monitoring when moving to long-term monitoring; Second, we proposed and benchmarked a beat detection method with adequate accuracy and usefulness in long-term scenarios. A longitudinal study was made with the most widely used waveform analysis algorithms, which allowed us to tune the free parameters of the required blocks, and a transversal study analyzed how these parameters change when moving to different databases. With all the above, the extension to long-term monitoring in a database of 7-day Holter monitoring was proposed and analyzed, by using an optimized simultaneous-multilead processing. We considered both own and public databases. In this new scenario, the noise-avoid mechanisms are more important due to the amount of noise that exists in these recordings, moreover, the computational efficiency is a key parameter in order to export the algorithm to the clinical practice. The method based on a Polling function outperformed the others in terms of accuracy and computational efficiency, yielding 99.48% sensitivity, 99.54% specificity, 99.69% positive predictive value, 99.46% accuracy, and 0.85% error for MIT-BIH arrhythmia database. We conclude that the method can be used in long-term Holter monitoring systems.

  4. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    Science.gov (United States)

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  5. Atrial fibrillation detected by external loop recording for seven days or two-day simultaneous Holter recording: A comparison in patients with ischemic stroke or transient ischemic attack.

    Science.gov (United States)

    Sejr, Michala Herskind; Nielsen, Jens Cosedis; Damgaard, Dorte; Sandal, Birgitte Forsom; May, Ole

    Atrial fibrillation (AF) is the most common cardiac cause of ischemic stroke and transient ischemic attack (IS/TIA). To compare the diagnostic value of seven-day external loop recording (ELR) and two-day Holter recording for detecting AF after IS/TIA. 191 IS/TIA patients without AF history. Endpoint was AF >30s. We started two-day Holter recording and seven-day ELR simultaneously. Seven-day ELR and two-day Holter recording detected the same three AF patients. ELR detected another six patients with AF adjudicated by cardiologists, four detections after Holter (3 vs. 7, p=0.125) and two false-positive detections during Holter. Seven-day ELR automatically classified 50/191 patients (26%) with AF, but only 7/50 (14%) were confirmed as AF by cardiologists. Seven-day ELR did not detect significantly more patients with AF than two-day Holter recording. 86% of patients with ELR-classified AF were false positives, indicating a poor performance of the automatic AF detection algorithm used. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. 45. Ezetimibe and statins yields on silent holter ambulatory myocardial ischemia

    Directory of Open Access Journals (Sweden)

    W. Kadro

    2016-07-01

    Full Text Available Further cholestrol lowering may affect silent ischemia detected on holter monitoring. Cholesterol lowering is associated with a reduction in cardiovascular morbidity and mortality. Statins are the main drugs for cholesterol lowering. Ezetimibe when added to statins gives further reduction in cholesterol but its long-term effect on cardiovascular morbidity and mortality and ischemic events is not known. This study sought to determine whether further cholesterol lowering with ezitimibe will also results in a reduction of myocardial ischemia during daily life. We enrolled 50 patients with proven stable coronary artery disease (CAD and at least one episode of ST-segment depression on ambulatory ECG monitoring. All of them were receiving optimal therapy for CAD including statin therapy for cholesterol reduction. 25 patients were randomized to continue their statin therapy (Statin only group and 25 to recieve statin plus ezitimibe 10 mg/day (ezitimibe group. Serum cholesterol and LDL cholesterol levels and ambulatory monitoring were repeated after 4–6 months of therapy. The two groups were comparable with respect to baseline characteristics, number of episodes of ST-segment depression, and baseline serum cholesterol levels. The ezitimibe group had lower mean total and LDL cholesterol levels at study end and experienced a significant reduction in the number of episodes of ST-segment depression compared with the statin only group. ST-segment depression was completely resolved in 13 of 25 patients (52% in the ezitimibe group versus 3 of 25 (12% in the statin only group. The ezitimibe group exhibited a highly significant reduction in ambulatory ischemia (P < .001. By logistic regression, treatment with ezitimibe was an independent predictor of ischemia resolution. Further cholesterol lowering with ezitimibe can result in reduction or resolution of myocardial ischemia recorded as episodes of ST-segment depression in ambulatory monitoring of the ECG.

  7. ST-segment deviation during 24-hour ambulatory electrocardiographic monitoring and exercise stress test in healthy male subjects 51 to 75 years of age: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner; Sørum, C

    1999-01-01

    or descending ST-segment depression of >/=0.15 mV during Holter monitoring or at the exercise test, respectively. Furthermore, the specificity was 0.95 when a horizontal or downsloping ST-segment depression of 0.1 mV was displayed in both the Holter and exercise electrocardiographic recording system......BACKGROUND: Although ST-segment deviation has been evaluated and used during many years both on continuous electrocardiographic Holter monitoring and during exercise stress testing, considerable controversy still remains concerning the prevalence and diagnostic significance of fortuitously...... discovered ST-segment deviation in asymptomatic healthy persons. METHODS AND RESULTS: The occurrence of ST-segment deviation was studied in a population of 63 clinically healthy male subjects 51 to 75 years of age, with the use of 24-hour Holter monitoring and exercise stress testing. The subjects were...

  8. Evaluation of the indications and arrhythmic patterns of 24 hour Holter electrocardiography among hypertensive and diabetic patients seen at OAUTHC, Ile-Ife Nigeria

    Directory of Open Access Journals (Sweden)

    Adebayo RA

    2014-11-01

    Full Text Available Rasaaq A Adebayo,1 Amanze N Ikwu,1 Michael O Balogun,1 Anthony O Akintomide,1 Tuoyo O Mene-Afejuku,1 Victor O Adeyeye,1 Olaniyi J Bamikole,1 Luqman A Bisiriyu,2 Olufemi E Ajayi,1 Suraj A Ogunyemi,1 Omolola A Oketona1 1Cardiology Unit, Department of Medicine, Obafemi Awolowo University Teaching Hospitals Complex, 2Department of Demography and Social Statistics, Obafemi Awolowo University, Ile-Ife, Osun State, Nigeria Background: There are very limited published studies in Nigeria on the use of 24 hour Holter electrocardiogram (Holter ECG in the arrhythmic evaluation of hypertensive and diabetic patients. Objective: To evaluate indications, arrhythmic pattern of Holter ECG, and heart rate variability (HRV among patients with hypertensive heart disease (HHD with or without heart failure and type 2 diabetes mellitus (T2DM seen in our cardiac care unit. Methods: Seventy-nine patients (32 males and 47 females were studied consecutively over a year using Schiller type (MT-101 Holter ECG machine. Results: Out of the 79 patients, 17 (21.5% had HHD without heart failure, 33 (41.8% had HHD with hypertensive heart failure (HHF, while 29 (36.7% were T2DM patients. The mean (standard deviation ages of HHD without heart failure, HHF and T2DM patients were 59.65 (±14.38, 65.15 (±14.30, and 54.66 (±8.88 respectively. The commonest indication for Holter ECG was palpitation (38%, followed by syncope (20.3%. Premature ventricular contraction was the commonest arrhythmic pattern among the 79 patients, especially among HHF patients. The HRV, using standard deviation of all normal-normal intervals was significantly reduced in T2DM patients (81.03±26.33, confidence interval [CI] =71.02–91.05 compared to the HHD without heart failure (119.65±29.86, CI =104.30–135.00 and HHF (107.03±62.50, CI =84.00–129.19. There was a negative correlation between the duration of T2DM and HRV (r=−0.613. Conclusion: Palpitation was the commonest Holter ECG indication and

  9. Predictive value of casual ECG-based resting heart rate compared with resting heart rate obtained from Holter recording

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Dixen, Ulrik; Marott, Jacob L

    2014-01-01

    BACKGROUND: Elevated resting heart rate (RHR) is associated with cardiovascular mortality and morbidity. Assessment of heart rate (HR) from Holter recording may afford a more precise estimate of the effect of RHR on cardiovascular risk, as compared to casual RHR. Comparative analysis was carried ...

  10. Development of an algorithm for heartbeats detection and classification in Holter records based on temporal and morphological features

    International Nuclear Information System (INIS)

    García, A; Romano, H; Laciar, E; Correa, R

    2011-01-01

    In this work a detection and classification algorithm for heartbeats analysis in Holter records was developed. First, a QRS complexes detector was implemented and their temporal and morphological characteristics were extracted. A vector was built with these features; this vector is the input of the classification module, based on discriminant analysis. The beats were classified in three groups: Premature Ventricular Contraction beat (PVC), Atrial Premature Contraction beat (APC) and Normal Beat (NB). These beat categories represent the most important groups of commercial Holter systems. The developed algorithms were evaluated in 76 ECG records of two validated open-access databases 'arrhythmias MIT BIH database' and M IT BIH supraventricular arrhythmias database . A total of 166343 beats were detected and analyzed, where the QRS detection algorithm provides a sensitivity of 99.69 % and a positive predictive value of 99.84 %. The classification stage gives sensitivities of 97.17% for NB, 97.67% for PCV and 92.78% for APC.

  11. An update on insertable cardiac monitors

    DEFF Research Database (Denmark)

    Olsen, Flemming J; Biering-Sørensen, Tor; Krieger, Derk W

    2015-01-01

    Continuous cardiac rhythm monitoring has undergone compelling progress over the past decades. Cardiac monitoring has emerged from 12-lead electrocardiograms being performed at the discretion of the treating physician to in-hospital telemetry, Holter monitoring, prolonged external event monitoring...... turning point in the field of arrhythmia management. However, their role in the detection of paroxysmal atrial fibrillation after cryptogenic strokes has yet to evolve. This will be the main focus of this review. Issues surrounding patient selection, clinical relevance and determination of cost......-effectiveness for prolonged cardiac monitoring require further studies. Furthermore, insertable cardiac monitoring has not only the potential to augment diagnostic capabilities but also to improve the management of paroxysmal atrial fibrillation....

  12. Holter con memorias SD y sistema experto de evaluación cardíaca

    OpenAIRE

    Pfarher, Iván; Reula, Germán; Tovorosky, Pablo; Zanin, Miguel; Caballero, Raúl M.; Maggiolo, Gustavo Daniel

    2006-01-01

    Este desarrollo se enmarca dentro de las actividades de la cátedra de Técnicas Digitales de Ingeniería en Electrónica en UTN-FRP y tiene como objeto potenciar la capacidad de diseño de los alumnos. En este caso se ha desarrollado un sistema holter utilizando memorias SD comunes en el mercado de las cámaras fotográficas implementando además un sistema ordenador de control a partir del uso de un microcontrolador con el sistema de operación y de captura embebido correspondiente para la captura, ...

  13. Ambulatory monitoring of myocardial ischemia in the 21st century-an opportunity for high frequency QRS analysis

    Czech Academy of Sciences Publication Activity Database

    Leinveber, Pavel; Halámek, Josef; Jurák, Pavel

    2016-01-01

    Roč. 49, č. 6 (2016), s. 902-906 ISSN 0022-0736 R&D Projects: GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : ambulatory monitoring * HF-QRS * myocardial Ischemia * silent Ischemia * Holter monitoring Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.514, year: 2016

  14. Psicologia aplicada à cardiologia: um estudo sobre emoções relatadas em exame de holter

    OpenAIRE

    Bonomo, Ana Myriam Sánchez; Araujo, Tereza Cristina Cavalcanti Ferreira de

    2009-01-01

    Estudos sobre fatores de risco associados a doenças do coração dão ênfase às emoções negativas e não esclarecem quanto aos efeitos cardíacos de vivências de alegria ou segurança. Realizou-se uma investigação com 30 pessoas submetidas ao exame de Holter 24 horas, visando identificar emoções e episódios de vida diária que ocorrem simultaneamente a arritmias cardíacas. Reuniram-se registros de arritmias, atividades e emoções, complementados por entrevistas semiestruturadas. Verificaram-se difere...

  15. Evaluation of Commercial Self-Monitoring Devices for Clinical Purposes

    DEFF Research Database (Denmark)

    Leth, Soren; Hansen, John; Nielsen, Olav W

    2017-01-01

    Commercial self-monitoring devices are becoming increasingly popular, and over the last decade, the use of self-monitoring technology has spread widely in both consumer and medical markets. The purpose of this study was to evaluate five commercially available self-monitoring devices for further...... activity trackers and compared to gyroscope readings. Two trackers were also tested on nine subjects by comparing pulse readings to Holter monitoring. RESULTS: The lowest average systematic error in the walking tests was -0.2%, recorded on the Garmin Vivofit 2 at 3.5 km/h; the highest error was the Fitbit...... the current functionality and limitations of the five self-tracking devices, and point towards a need for future research in this area....

  16. Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.

    Science.gov (United States)

    Kollias, Anastasios; Destounis, Antonios; Kalogeropoulos, Petros; Kyriakoulis, Konstantinos G; Ntineri, Angeliki; Stergiou, George S

    2018-07-01

    This study assessed the diagnostic accuracy of a novel 24-hour ambulatory blood pressure (ABP) monitor (Microlife WatchBP O3 Afib) with implemented algorithm for automated atrial fibrillation (AF) detection during each ABP measurement. One hundred subjects (mean age 70.6±8.2 [SD] years; men 53%; hypertensives 85%; 17 with permanent AF; 4 paroxysmal AF; and 79 non-AF) had simultaneous 24-hour ABP monitoring and 24-hour Holter monitoring. Among a total of 6410 valid ABP readings, 1091 (17%) were taken in ECG AF rhythm. In reading-to-reading ABP analysis, the sensitivity, specificity, and accuracy of ABP monitoring in detecting AF were 93%, 87%, and 88%, respectively. In non-AF subjects, 12.8% of the 24-hour ABP readings indicated false-positive AF, of whom 27% were taken during supraventricular premature beats. There was a strong association between the proportion of false-positive AF readings and that of supraventricular premature beats ( r =0.67; P ABP monitoring had 100%/85% sensitivity/specificity (area under the curve 0.91; P ABP monitor with AF detector has high sensitivity and moderate specificity for AF screening during routine ABP monitoring. Thus, in elderly hypertensives, a 24-hour ABP recording with at least 26% of the readings suggesting AF indicates a high probability for AF diagnosis and should be regarded as an indication for performing 24-hour Holter monitoring. © 2018 American Heart Association, Inc.

  17. Smartphone electrographic monitoring for atrial fibrillation in acute ischemic stroke and transient ischemic attack.

    Science.gov (United States)

    Tu, Hans T; Chen, Ziyuan; Swift, Corey; Churilov, Leonid; Guo, Ruibing; Liu, Xinfeng; Jannes, Jim; Mok, Vincent; Freedman, Ben; Davis, Stephen M; Yan, Bernard

    2017-10-01

    Rationale Paroxysmal atrial fibrillation is a common and preventable cause of devastating strokes. However, currently available monitoring methods, including Holter monitoring, cardiac telemetry and event loop recorders, have drawbacks that restrict their application in the general stroke population. AliveCor™ heart monitor, a novel device that embeds miniaturized electrocardiography (ECG) in a smartphone case coupled with an application to record and diagnose the ECG, has recently been shown to provide an accurate and sensitive single lead ECG diagnosis of atrial fibrillation. This device could be used by nurses to record a 30-s ECG instead of manual pulse taking and automatically provide a diagnosis of atrial fibrillation. Aims To compare the proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring with current standard practice. Sample size 296 Patients. Design Consecutive ischemic stroke and transient ischemic attack patients presenting to participating stroke units without known atrial fibrillation will undergo intermittent AliveCor™ ECG monitoring administered by nursing staff at the same frequency as the vital observations of pulse and blood pressure until discharge, in addition to the standard testing paradigm of each participating stroke unit to detect paroxysmal atrial fibrillation. Study outcome Proportion of patients with paroxysmal atrial fibrillation detected by AliveCor™ ECG monitoring compared to 12-lead ECG, 24-h Holter monitoring and cardiac telemetry. Discussion Use of AliveCor™ heart monitor as part of routine stroke unit nursing observation has the potential to be an inexpensive non-invasive method to increase paroxysmal atrial fibrillation detection, leading to improvement in stroke secondary prevention.

  18. Monitoring and Detection Platform to Prevent Anomalous Situations in Home Care

    Directory of Open Access Journals (Sweden)

    Gabriel Villarrubia

    2014-06-01

    Full Text Available Monitoring and tracking people at home usually requires high cost hardware installations, which implies they are not affordable in many situations. This study/paper proposes a monitoring and tracking system for people with medical problems. A virtual organization of agents based on the PANGEA platform, which allows the easy integration of different devices, was created for this study. In this case, a virtual organization was implemented to track and monitor patients carrying a Holter monitor. The system includes the hardware and software required to perform: ECG measurements, monitoring through accelerometers and WiFi networks. Furthermore, the use of interactive television can moderate interactivity with the user. The system makes it possible to merge the information and facilitates patient tracking efficiently with low cost.

  19. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    Science.gov (United States)

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86Holter at rest, during 6MW and recovery. At higher rates, a small effect in increasing differences between Holter and Polar in R-R intervals was observed. In conclusion, our study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.

  20. QTc interval prolongation in HIV-infected patients: a case–control study by 24-hour Holter ECG recording

    Directory of Open Access Journals (Sweden)

    Fiorentini Alessandra

    2012-12-01

    Full Text Available Abstract Background Aim of the study was to assess QTc interval by a 24-hour ECG recording in a group of HIV-infected individuals with a basal prolonged QTc. The risk factors associated with QTc prolongation and the indices of cardiovascular autonomic control were also evaluated. Methods A case–control study was performed using as cases 32 HIV-infected patients with prolonged (>440 msec QTc interval as assessed by Holter ECG, and as controls 64 HIV-infected subjects with normal QTc interval. Autonomic function was evaluated by heart rate variability analysis during 24-hour recording. Results Duration of HIV disease was significantly longer among cases than among controls (p=0.04. Waist/hip ratio was also higher among cases than among controls (p=0.05. Frequency domain analysis showed the absence of physiologic decrease of low frequency (LF in the night period in both cases and controls. The LF night in cases showed a statistically significant reduction when compared with controls (p=0.007. Conclusions In our study group, QTc interval prolongation was associated with a longer duration of HIV infection and with a greater waist/hip ratio. HIV patients with QTc interval prolongation and with a longer duration of HIV infection were more likely to have an impairment of parasympathetic and sympathetic cardiac component.

  1. Recomendações da sociedade brasileira de arritmias cardíacas para serviços de holter

    Directory of Open Access Journals (Sweden)

    Adalberto Lorga Filho

    2013-08-01

    Full Text Available FUNDAMENTOS: Inúmeros indicadores são utilizados para assegurar a qualidade de um serviço; entretanto, a competência médica e o adequado fluxo de realização de um procedimento são determinantes da qualidade final. Nesse contexto, a Sociedade Brasileira de Arritmias Cardíacas pretende recomendar parâmetros mínimos necessários para garantir a excelência dos serviços de monitorização eletrocardiográfica ambulatorial. OBJETIVOS: Recomendar competências médicas mínimas e as informações necessárias para emissão do laudo de Holter. MÉTODOS: O documento foi fundamentado no conceito de medicina baseada em evidência, e nas circunstâncias em que a evidência não estava disponível a opinião de uma comissão de redação foi utilizada para a formulação da recomendação. Essa comissão foi formada por profissionais que apresentam vivência nas dificuldades do método e gestão na prestação de serviços nessa área. RESULTADOS: O profissional responsável pela análise de Holter deve conhecer as patologias cardiovasculares e ter formação consistente em eletrocardiografia, incluindo arritmias cardíacas e seus diagnósticos diferenciais. O laudo deve ser redigido de forma clara e objetiva. Os parâmetros mínimos que devem constar no laudo incluem as estatísticas do exame, assim como quantificação e análise dos distúrbios do ritmo observados durante a monitorização. CONCLUSÃO: A monitorização eletrocardiográfica ambulatorial deve ser realizada por profissionais com vivência em análise eletrocardiográfica e o laudo deve conter os parâmetros mínimos mencionados nesse documento.

  2. Psicologia aplicada à cardiologia: um estudo sobre emoções relatadas em exame de holter

    Directory of Open Access Journals (Sweden)

    Ana Myriam Sánchez Bonomo

    Full Text Available Estudos sobre fatores de risco associados a doenças do coração dão ênfase às emoções negativas e não esclarecem quanto aos efeitos cardíacos de vivências de alegria ou segurança. Realizou-se uma investigação com 30 pessoas submetidas ao exame de Holter 24 horas, visando identificar emoções e episódios de vida diária que ocorrem simultaneamente a arritmias cardíacas. Reuniram-se registros de arritmias, atividades e emoções, complementados por entrevistas semiestruturadas. Verificaram-se diferenças acentuadas entre gêneros: mulheres apresentaram mais arritmias que homens. Nas mulheres, arritmias ventriculares ocorreram mais simultaneamente à preocupação do que à ansiedade e não se mostraram relacionadas à raiva. A tristeza não foi associada a arritmias ventriculares por nenhum dos gêneros.

  3. Adapting detection sensitivity based on evidence of irregular sinus arrhythmia to improve atrial fibrillation detection in insertable cardiac monitors.

    Science.gov (United States)

    Pürerfellner, Helmut; Sanders, Prashanthan; Sarkar, Shantanu; Reisfeld, Erin; Reiland, Jerry; Koehler, Jodi; Pokushalov, Evgeny; Urban, Luboš; Dekker, Lukas R C

    2017-10-03

    Intermittent change in p-wave discernibility during periods of ectopy and sinus arrhythmia is a cause of inappropriate atrial fibrillation (AF) detection in insertable cardiac monitors (ICM). To address this, we developed and validated an enhanced AF detection algorithm. Atrial fibrillation detection in Reveal LINQ ICM uses patterns of incoherence in RR intervals and absence of P-wave evidence over a 2-min period. The enhanced algorithm includes P-wave evidence during RR irregularity as evidence of sinus arrhythmia or ectopy to adaptively optimize sensitivity for AF detection. The algorithm was developed and validated using Holter data from the XPECT and LINQ Usability studies which collected surface electrocardiogram (ECG) and continuous ICM ECG over a 24-48 h period. The algorithm detections were compared with Holter annotations, performed by multiple reviewers, to compute episode and duration detection performance. The validation dataset comprised of 3187 h of valid Holter and LINQ recordings from 138 patients, with true AF in 37 patients yielding 108 true AF episodes ≥2-min and 449 h of AF. The enhanced algorithm reduced inappropriately detected episodes by 49% and duration by 66% with adapts sensitivity for AF detection reduced inappropriately detected episodes and duration with minimal reduction in sensitivity. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Cardiology

  4. Holter monitoring of central and peripheral temperature: possible uses and feasibility study in outpatient settings.

    Science.gov (United States)

    Varela, Manuel; Cuesta, David; Madrid, Juan Antonio; Churruca, Juan; Miro, Pau; Ruiz, Raul; Martinez, Carlos

    2009-08-01

    Conventional clinical thermometry has important limitations. A continuous monitoring of temperature may offer significant advantages, including the use of chronobiological and complexity analysis of temperature profile and eventually the identification of a "pre-febrile" pattern. We present a clinical model designed to measure, store and/or transmit in real time a central and a peripheral temperature reading. The results of its use in a healthy, free-living population is reported. Thirty subjects (15 women, 15 men, 20-70 years old), were monitored for 24 h while following their normal life. Temperatures were recorded every minute at the external auditory channel (EAC) and on the skin, at the intersection of the 5th intercostal space and the anterior axillary line. A Cosinor analysis and Approximate Entropy (ApEn) (m = 2, r = 0.15*SD, N = 180) were calculated for both temperatures. Median temperature was 35.55 degrees C [interquartile range (IR) 0.77 degrees C] in the external auditory channel (EAC) and 34.62 degrees C (IR 1.61) in the specified skin location. Median gradient between AEC and skin was 0.93 (IR 1.57). A circadian rhythm was present both in EAC and skin temperature, with a mean amplitude of 0.44 degrees C and an acrophase at 21:02 for the EAC and 0.70 degrees C and 00:42 for the skin. During the night there was a sizable increase in peripheral temperature, with a decrease in gradient and a loss of complexity in the temperature profile, most significantly in the peripheral temperature. Continuous monitoring of central and peripheral temperature may be a helpful tool in both ambulatory and admitted patients and may offer new approaches in clinical thermometry.

  5. Effects of atomoxetine on heart rhythm in children and adolescents.

    Science.gov (United States)

    Tanidir, Ibrahim Cansaran; Tanidir, Canan; Ozturk, Erkut; Bahali, Kayhan; Gunes, Hatice; Ergul, Yakup; Uneri, Ozden Sukran; Akdeniz, Celal; Tuzcu, Volkan

    2015-12-01

    The aim of this study was to examine the effects of atomoxetine on heart rhythm using 12-lead electrocardiography (ECG) and 24 h Holter monitoring. Children and adolescents who were diagnosed with attention deficit-hyperactivity disorder according to DSM-IV-TR were referred to a pediatric cardiology clinic for cardiologic examination before and after 4 or 5 weeks of atomoxetine treatment. Cardiac examination, complete blood count, biochemistry, thyroid function tests, 12-lead ECG and 24 h Holter monitoring were performed routinely in all patients. Each subject underwent 24 h Holter ECG monitoring before atomoxetine was started and after 4 or 5 weeks of effective dose atomoxetine treatment. Forty-one patients were included in this prospective study. No statistically significant change was found in QT, QTc or QT interval dispersion or blood pressure before and after 4 or 5 weeks of atomoxetine treatment. There was a statistically significant increase in heart rate (both during the day and at night) and QRS duration, and a statistically significant decrease in P wave dispersion. Three patients had rhythm disturbances. All of these three patients were asymptomatic and none of these arrhythmias reached clinical significance. Atomoxetine did not cause significant changes in ECG or Holter variables. In two patients, who had undiagnosed subclinical extrasystoles, extra beats were increased after 4th week of treatment, but still remained clinically insignificant. Before and after atomoxetine treatment, listening to the heart sounds for a longer time, may help clinicians to notice an extra beat. If an extra beat is identified then 24 Holter monitoring is recommended. © 2015 Japan Pediatric Society.

  6. Bedside identification of patients at risk for PVC-induced cardiomyopathy: Is ECG useful?

    Science.gov (United States)

    Garster, Noelle C; Henrikson, Charles A

    2017-07-01

    Premature ventricular complexes (PVCs) are an underrecognized cause of cardiomyopathy. Standard 12-lead electrocardiogram (ECG) has potential to direct attention toward at-risk patients. We performed a single-center, retrospective chart review of 1,240 patients who completed ECG and Holter monitoring at Oregon Health and Science University Hospital between January 1, 2011 and December 31, 2013 to investigate the relationship of PVC frequency on ECG with burden on Holter. Primary outcome measures included PVC quantity on ECG, mean PVC quantity on Holter, and percentage of total beats on Holter recorded as PVCs. High PVC burden was defined as ≥10% of total beats. Weighted mean percentages of total beats on Holter monitor recorded as PVCs were calculated for 0, 1, 2, and ≥3 PVCs on ECG and found to be 1.4% (n = 1,128), 3.5% (n = 32), 4.3% (n = 25), and 16.6% (n = 55), respectively, which represent statistically significant differences (P ECG for ≥10% PVC Holter burden was 58%. Negative predictive value for 0 PVCs on ECG was 98%. The sensitivity and specificity of ECG to identify high PVC burden on Holter was 72% and 93.6%, respectively, when utilizing a positive ECG result as one PVC or more, and 44% and 98.9%, respectively, with ≥3 PVCs on ECG. The positive likelihood ratio corresponding to ≥3 PVCs on ECG was 40. These findings demonstrate that the number of PVCs on ECG can be utilized for quick bedside estimation of high PVC burden. © 2017 Wiley Periodicals, Inc.

  7. Electrocardiographic Patch Devices and Contemporary Wireless Cardiac Monitoring

    Directory of Open Access Journals (Sweden)

    Erik eFung

    2015-05-01

    Full Text Available Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG, Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable ‘on-body’ ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery.

  8. Comparison of two systems for long-term heart rate variability monitoring in free-living conditions - a pilot study

    DEFF Research Database (Denmark)

    Kristiansen, Jesper; Korshoj, Mette; Skotte, Jorgen H

    2011-01-01

    Actiheart and Holter recorders, and signals were processed to RR-interval time series. Segments of 5-minute duration were sampled every 30 minutes, and spectral components of the heart rate variability were calculated. Actiheart and Holter values were compared using Deming regression analysis and Bland...

  9. [Limits of cardiac functional adaptation in "top level" resistance athletes].

    Science.gov (United States)

    Carù, B; Righetti, G; Bossi, M; Gerosa, C; Gazzotti, G; Maranetto, D

    2001-02-01

    Sports activity, particularly when performed at high level, provokes cardiovascular adjustments depending on the type of sport and on the level of the load. We evaluated 15 athletes from the Italian national team during a non-agonistic period of cross country skiing, with non-invasive tests including exercise test, color Doppler echocardiography, Holter monitoring, physical examination and standard rest electrocardiogram. Physical examination, rest electrocardiogram, exercise testing and echocardiography were all within the range of the expected values for this type of subjects. Holter monitoring recorded during the periods of agonistic activity revealed significant hypokinetic arrhythmias such as severe bradycardia, pauses, I and II degree atrioventricular blocks, and complete atrioventricular block in 2 cases; these features were not observed on Holter monitoring recorded during the non-agonistic period. The perfect health status of subjects and their racing results may bring about physiological functional adjustments, but these observations suggest the need for a follow-up to evaluate possible pathologic outcomes.

  10. Effects of citalopram on heart rate variability in women with generalized anxiety disorder

    Directory of Open Access Journals (Sweden)

    Fatemeh Ranjbar

    2015-07-01

    Full Text Available BACKGROUND: Heart rate variability (HRV is defined as variations in R-R interval with time. Dysautonomia is common in patients with psychiatric disorders such as depression and anxiety. Using HRV analysis, recent studies showed that in anxiety disorders, the vagal cardiac function decreases, and sympathetic function increases. This study aimed at investigating citalopram effects on HRV. METHODS: This before and after study was conducted in 25 generalized anxiety disorder (GAD patients. GAD was diagnosed based on clinical interview according to diagnostic and statistical manual of mental disorders IV-Text revised (DSM-IV-TR criteria using Structured Clinical Interview for DSM Disorders-I questionnaire. A cardiologist studied 24 h ambulatory monitoring of the electrocardiogram (Holter on all patients before the treatment. A volume of 20 mg of citalopram was administered to the subjects on a daily basis. Then, they were studied by Holter monitoring again after 1-month of administration of citalopram. RESULTS: The average age of participants was 35.32 ± 8.7. The average Holter monitoring time was 23.29 ± 1.14 h before treatment and 23.81 ± 0.68 after it. The 3 h low frequency/high frequency ratio was significantly different between 3 h segments of time before treatment (P < 0.001. This difference was even higher after treatment (P = 0.001. Data showed an increase in parasympathetic tone during sleep both before and after treatment. CONCLUSION: These patients showed some impairments of HRV indices that did not improve by citalopram in future, the clinical importance of such disturbances should be evaluated in details with prolonged follow-up and greater sample size.   

  11. Monitorização eletrocardiográfica ambulatorial por 24-horas em cães com cardiomiopatia dilatada idiopática Twenty-four-hour ambulatory electrocardiographic monitoring in dogs with idiopathic dilated cardiomyopathy

    Directory of Open Access Journals (Sweden)

    F.L. Yamaki

    2007-12-01

    Full Text Available Caracterizou-se monitorização eletrocardiográfica ambulatorial por 24 horas (ou monitorização Holter em cães com cardiomiopatia dilatada idiopática, visando principalmente à detecção de arritmias ventriculares não detectadas pela eletrocardiografia convencional (de repouso. Para tanto, avaliaram-se 40 pacientes com diagnóstico de cardiomiopatia dilatada idiopática, por meio de exame físico e mensuração indireta da pressão arterial, além de exames eletrocardiográfico, ecocardiográfico, radiográfico de tórax e da monitorização Holter. Extra-sístoles ventriculares foram detectadas, por monitorização Holter, em 97,5% dos animais e taquicardia ventricular, em 45%. Não houve correlação entre o número de extra-sístoles ventriculares e a fração de encurtamento. Considerando as manifestações clínicas, apenas houve associação entre presença de taquicardia ventricular e histórico de síncopes. Conclui-se que a incidência de arritmias ventriculares em cães com cardiomiopatia dilatada idiopática é bastante alta, sendo a taquicardia ventricular relativamente freqüente, ocorrendo mais sob a forma não sustentada.This study aimed to characterize 24-hour ambulatory electrocardiographic monitoring (Holter monitoring in dogs with idiopathic dilated cardiomyopathy. Physical examination and indirect (Doppler blood pressure measurement, and also electrocardiography, thoracic radiography, echocardiography, and 24-hour ambulatory electrocardiographic exams were performed in 40 dogs with idiopathic dilated cardiomyopathy. Ventricular extrasystoles were detected in 97.5% of the animals, and ventricular tachycardia in 45%. No correlation between the number of ventricular extrasystoles and the shortening fraction was observed. Concerning the clinical symptoms, there was only association between the presence of ventricular tachycardia and past report of syncope. It was concluded that the incidence of ventricular arrhythmias is

  12. Low Incidence of Atrial Fibrillation in Patients with Transient Ischemic Attack

    DEFF Research Database (Denmark)

    Pedersen, Kenneth Bruun; Chemnitz, Alexander; Madsen, Charlotte

    2016-01-01

    on admission ECG. Another 2 (1.2%) were diagnosed with AF on Holter monitoring. In total, 6 patients (3.5%) were diagnosed with AF. Patients with AF were significantly older (mean age 79.4 [95% CI 65.1-93.6] years) than patients without AF (mean age 67.6 [95% CI 65.6-69.5] years) but otherwise showed...

  13. The Effect of Valsartan on Heart Rate Variability and Heart Rate Recovery in Patients with Mild to Moderate Mitral Stenosis

    Directory of Open Access Journals (Sweden)

    Ali Metin Esen

    2010-04-01

    Full Text Available Summary: Atrial fibrillation (AF is known to be one of the most important complications of mitral stenosis (MS. It has been reported that autonomic nervous system (ANS had an effect on AF development, heart rate variability (HRV and heart rate recovery (HRR were under the control of ANS, and their disorders were present in MS. We studied the effect of Valsartan on HRV and HRT, and thus its effect on ANS. Methods: Eleven patients (39±8 years, 10 females with mild to moderate MS were included in the study. Sixteen volunteers (38±8 years, 14 females matched for age and sex were selected for control group. All subjects underwent transthoracic echocardiography (TTE, symptom-limited treadmill test and 24 hour Holter monitorization.The patients were administered 160 mg of Valsartan daily for 14 weeks. TTE, treadmill test and Holter monitorization were repeated at the end of treatment period. In Holter monitorization, the time and frequency domain analysis of HRV and in exercise test, HRR at first and third minutes (HRR1 and HRR3 were examined. Results: Before Valsartan treatment, no significant difference was found in HRR and HRV parameters between the two groups. Systolic and diastolic blood pressure, and also HRR1values were significantly decreased after treatment of Valsartan (117±6 vs. 107±4 mmHg p<0.002, 76±6 vs. 69±9 mmHg p<0.044, 44±14 vs. 33±12 p< 0.014, respectively, while the exercise time was significantly increased (786±114 vs. 846±95 sn p< 0.044. In Holter analysis neither time nor frequency domain of HRV parameters showed a meaningful change. Conclusion: In moderate MS, treatment with Valsartan improved the effort capacity, while autonomic function parameters have been defined on the base of HRV and HRR were not significantly different.

  14. Arrhythmias and conduction abnormalities in children after repair of tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Kuzevska-Maneva Konstandina

    2005-01-01

    Full Text Available Aim. To find out types and frequency of cardiac arrhythmias and conduction abnormalities in the group of children who underwent surgery for tetralogy of Fallot (TOF. Methods. Fortysix pedicatric patients who underwent a complete repair of TOF at the age of 1 to 13 (mean 2.89 ± 2.36 were studied. Thirty-eight (82.60% had total correction and 8 (17.40% had palliative operation first, and total correction afterwards. Twenty-four-hour Holter ECG monitoring was performed in all 46 pediatric patients aged from 1 to 16 yrs (mean 6.48 ± 4.04 after surgery as follows: in 1 patient (2.17% after a year, in 20 patients (43.47% after 2 to 5 years and in 25 patients (54.34% after 5 years. Mean age of patients on Holter monitoring was 9.25 ± 4.39 (range 4−19. Twenty of them (43.47% were girls and 28 (56.53% were boys. All the patients were evaluated by standard methods (clinical signs, clinical findings, ECG before surgery, ECG before Holter monitoring and 2D Doppler echocardiography. Results. Types of heart rhythm found out by Holter monitoring were: sinus nodus dysfunction in 1 child (2.17%, significant premature atrial contraction (PAC in 8 (17.39%, supraventricular paroxysmal tachycardia in 3 (6.53%, transient nodal rhythm in 2 (4.34%, premature ventricular contraction (PVC Lown grade I-III in 9 (19.56% and Lown grade IV in 2 (4.34, atrioventricular (AV block grade I in 2, right bundle branch block (RBBB in all 46 (100% and RBBB + left anterior hemiblock (LAH in 4 (8.96%. There was no presence of atrial flutter, ventricular tachycardia or complete AV block. None of them experienced sudden death. Using cross procedure statistical methods, it was found that all the patients with PVC had right ventricular dilatation. There was no relation of other types of arrhythmia found on Holter monitoring to the other parameters from echocardiography, neither to the other standard methods. Children did not need the pace-maker, but 36.95% of the them required

  15. Ventricular Repolarization Evaluation From Surface ECG for Identification of the Patients With Increased Myocardial Electrical Instability

    National Research Council Canada - National Science Library

    Lass, Jaanus

    2001-01-01

    In order to reveal the possible correlation between the level of myocardial electrical instability assessed at Holter monitoring and certain ECG parameters characterizing ventricular repolarization...

  16. Electro-resistive bands for non-invasive cardiac and respiration monitoring, a feasibility study

    International Nuclear Information System (INIS)

    Gargiulo, Gaetano D; Breen, Paul P; O’Loughlin, Aiden

    2015-01-01

    Continuous unobtrusive monitoring of tidal volume, particularly for critical care patients (i.e. neonates and patients in intensive care) during sleep studies and during daily activities, is still an unresolved monitoring need. Also a successful monitoring solution is yet to be proposed for continuous non-invasive cardiac stroke volume monitoring that is a novel clinical need. In this paper we present the feasibility study for a wearable, non-invasive, non-contact and unobtrusive sensor (embedded in a standard T-shirt) based on four electro-resistive bands that simultaneously monitors tidal volume and cardiac stroke volume changes. This low power sensor system (requires only 100 mW and accepts a wide power supply range up to ±18 V); thus the sensor can be easily embedded in existing wearable solutions (i.e. Holter monitors). Moreover, being contactless, it can be worn over bandages or electrodes, and as it does not rely over the integrity of the garment to work, it allows practitioners to perform procedures during monitoring. For this preliminary evaluation, one subject has worn the sensor over the period of 24 h (removing it only to shower); the accuracy of the tidal volume tested against a portable spirometer reported a precision of ±10% also during physical activity; accuracy tests for cardiac output (as it may require invasive procedure) have not been carried out in this preliminary trial. (note)

  17. The Telemetric and Holter ECG Warehouse Initiative (THEW): a Data Repository for the Design, Implementation and Validation of ECG-related Technologies

    Science.gov (United States)

    Couderc, Jean-Philippe

    2011-01-01

    We present an initiative supported by the National Heart Lung, and Blood Institute and the Food and Drug Administration for the development of a repository containing continuous electrocardiographic information to be shared with the worldwide scientific community. We believe that sharing data reinforces open scientific inquiry. It encourages diversity of analysis and opinion while promoting new research and facilitating the education of new researchers. In this paper, we present the resources available in this initiative for the scientific community. We describe the set of ECG signals currently hosted and we briefly discuss the associated clinical information (medical history. Disease and study-specific endpoints) and software tools we propose. Currently, the repository contains more than 250GB of data from eight clinical studies including healthy individuals and cardiac patients. This data is available for the development, implementation and validation of technologies related to body-surface ECGs. To conclude, the Telemetric and Holter ECG Warehouse (THEW) is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. PMID:21097349

  18. The Brugada syndrome. Outcome of one case

    Directory of Open Access Journals (Sweden)

    Maia Ivan G.

    2000-01-01

    Full Text Available The Brugada syndrome is a rare condition, and due to its mutating manner of presentation it may be difficult to diagnose. We report one case and discuss the diagnostic aspects and the clinical outcome of one patient with characteristic findings of this syndrome. These findings are especially defined by J-ST elevation in the right leads of serial electrocardiographic records, wide oscillations of J points and ST segments during 24-hour Holter monitoring, and nocturnal sudden death. We stress the importance of the Holter monitor findings for diagnostic complementation. Through this method it is possible to establish a correlation between vigil activities and sleep and the variability of the degree of impairment in ventricular repolarization.

  19. [Evaluation of the radiofrequency ablation effectiveness in patients with the Wolff-Parkinson-White syndrome].

    Science.gov (United States)

    Ushakov, I B; Ardashev, A V; Ardashev, V N; Voronkov, Iu I; Sharoĭko, M V; Akimova, O S

    2012-01-01

    A one-year prospective study involved 22 patients with the Wolff-Parkinson-White syndrome (WPW) and 20 healthy people. Means age of patients was 34.3 +/- 16.3 years. All 22 patients were successfully treated with radiofrequency ablation (RFA) of additional pathways. RFA effectiveness was evaluated with the help of clinical questionnaire, data of ECG, EchoCG, heart rate variability (HRV), frequency response and nonlinear dynamics. Cardiac rhythm disturbances were verified using Holter monitoring applied to all patients. Positive clinical effect was achieved in all the WPW patients, as RFA arrested cardiac arrhythmias completely. Holter monitoring did not register cardiac disturbances which points to high RFA effectiveness in WPW patients. HRV, frequency response and nonlinear dynamics reassumed their normal patterns.

  20. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA

    Directory of Open Access Journals (Sweden)

    Christie E Tung

    2015-01-01

    Full Text Available Background: It is important to evaluate patients with TIA or stroke for atrial fibrillation (AF because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch in patients with stroke or TIA.Methods: We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies. Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. Results: 1,171 monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0. The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%. AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 hours. The mean PAF burden was 12.7% of the total monitoring duration. Conclusion: Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 hours of monitoring suggest that the cardiac patch is superior to conventional 48-hour Holter monitors for AF detection in patients with stroke or TIA.

  1. Diagnostic Yield of Extended Cardiac Patch Monitoring in Patients with Stroke or TIA.

    Science.gov (United States)

    Tung, Christie E; Su, Derek; Turakhia, Mintu P; Lansberg, Maarten G

    2014-01-01

    It is important to evaluate patients with transient ischemic attack (TIA) or stroke for atrial fibrillation (AF) because the detection of AF changes the recommended anti-thrombotic regimen from treatment with an antiplatelet agent to oral anticoagulation. This study describes the diagnostic yield of a patch-based, single-use, and water-resistant 14-day continuous cardiac rhythm monitor (ZIO Patch) in patients with stroke or TIA. We obtained data from the manufacturer and servicer of the ZIO Patch (iRhythm Technologies). Patients who were monitored between January 2012 and June 2013 and whose indication for monitoring was TIA or stroke were included. The duration of monitoring, the number and type of arrhythmias, and the time to first arrhythmia were documented. One thousand one hundred seventy-one monitoring reports were analyzed. The mean monitor wear time was 10.9 days and the median wear time was 13.0 days (interquartile range 7.2-14.0). The median analyzable time relative to the total wear time was 98.7% (IQR 96.0-99.5%). AF was present in 5.0% of all reports. The mean duration before the first episode of paroxysmal AF (PAF) was 1.5 days and the median duration was 0.4 days. 14.3% of first PAF episodes occurred after 48 h. The mean PAF burden was 12.7% of the total monitoring duration. Excellent quality of the recordings and very good patient compliance coupled with a substantial proportion of AF detection beyond the first 48 h of monitoring suggest that the cardiac patch is superior to conventional 48-h Holter monitors for AF detection in patients with stroke or TIA.

  2. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    International Nuclear Information System (INIS)

    Sultana, R.; Sultana, N.; Rashid, A.; Rasheed, S.Z.; Ahmed, M.; Ishaq, M.; Samad, A.

    2010-01-01

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  3. Cardiac arrhythmias and left ventricular hypertrophy in systemic hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Sultana, R; Sultana, N; Rashid, A; Rasheed, S Z; Ahmed, M; Ishaq, M; Samad, A [Karachi Institute of Heart Diseases, Karachi (Pakistan)

    2010-10-15

    Background: Hypertensive left ventricular hypertrophy (LVH) is associated with increased risk of arrhythmias and mortality. Objective was to investigate the prevalence of cardiac arrhythmias and LVH in systemic hypertension. Methods: In all subjects blood pressure was measured, electrocardiography and echocardiography was done. Holter monitoring and exercise test perform in certain cases. There were 500 hypertensive patients, 156 (31.2%) men and 344 (69%) women >30 years of age in the study. Among them 177 (35.4%) were diabetic, 224 (45%) were dyslipidemia, 188 (37.6%) were smokers, and 14 (3%) had homocysteinemia. Mean systolic BP (SBP) was 180 +- 20 mm Hg and diastolic BP (DBP) was 95 +- 12 in male and female patients. Left ventricular mass index (LVMI) was 119.2 +- 30 2 2gm/m in male while 103 +- 22 gm/m in female patients. Palpitation was seen in 126 (25%) male and 299 (59.8%) female patients. Atrial fibrillation was noted in 108 (21.6%) male and 125 (25%) female patients, 30 (6%) male and 82 (16.4%) female patients had atrial flutter. Ventricular tachycardia was noted in 37 (7.4%) male and 59 (11.8%) female patients. Holter monitoring showed significant premature ventricular contractions (PVC'S) in 109 (21.8%) male and 128 (25.69%) female patients while Holter showed atrial arrhythmias (APC'S) in 89 (17.8%) males and 119 (23.8%) females. Angiography findings diagnosed coronary artery disease in 119 (23.8%) with CAD male and 225 (45%) without CAD while 47 (9.4%) females presented with CAD and 109 (21.8%) without CAD. Conclusion: A significant association has been demonstrated between hypertension and arrhythmias. Diastolic dysfunction of the left ventricle, left atrial size and function, as well as LVH have been suggested as the underlying risk factors for supraventricular, ventricular arrhythmias and sudden death in hypertensives with LVH. (author)

  4. Usefulness of simultaneous and sequential monitoring of glucose level and electrocardiogram in monkeys treated with gatifloxacin under conscious and nonrestricted conditions.

    Science.gov (United States)

    Yoshimatsu, Yu; Ishizaka, Tomomichi; Chiba, Katsuyoshi; Mori, Kazuhiko

    2018-05-10

    Drug-induced cardiac electrophysiological abnormalities accompanied by hypoglycemia or hyperglycemia increase the risk for life-threatening arrhythmia. To assess the drug-induced cardiotoxic potential associated with extraordinary blood glucose (GLU) levels, the effect of gatifloxacin (GFLX) which was frequently associated with GLU abnormality and QT/QTc prolongations in the clinic on blood GLU and electrocardiogram (ECG) parameters was investigated in cynomolgus monkeys (n=4) given GFLX orally in an ascending dose regimen (10, 30, 60 and 100 mg/kg). Simultaneous and sequential GLU and ECG monitoring with a continuous GLU monitoring system and Holter ECG, respectively, were conducted for 24 h under free-moving conditions. Consequently, GFLX at 30 and 60 mg/kg dose-dependently induced a transient decrease in GLU without any ECG abnormality 2-4 h postdose. Highest dose of 100 mg/kg caused severe hypoglycemia with a mean GLU of sequential GLU monitoring data clearly distinguished between GFLX-induced GLU abnormality and physiological GLU changes influenced by feeding throughout the day. In conclusion, the combined assessment of continuous GLU and ECG monitoring is valuable in predicting the drug-induced cardio-electrophysiological risk associated with both GLU and ECG abnormalities.

  5. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Directory of Open Access Journals (Sweden)

    Cristina Soguero-Ruiz

    2018-03-01

    Full Text Available Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT, and a complex-domain (heart rate variability (HRV. Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT. The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain.

  6. An Interoperable System toward Cardiac Risk Stratification from ECG Monitoring

    Science.gov (United States)

    Mora-Jiménez, Inmaculada; Ramos-López, Javier; Quintanilla Fernández, Teresa; García-García, Antonio; Díez-Mazuela, Daniel; García-Alberola, Arcadi

    2018-01-01

    Many indices have been proposed for cardiovascular risk stratification from electrocardiogram signal processing, still with limited use in clinical practice. We created a system integrating the clinical definition of cardiac risk subdomains from ECGs and the use of diverse signal processing techniques. Three subdomains were defined from the joint analysis of the technical and clinical viewpoints. One subdomain was devoted to demographic and clinical data. The other two subdomains were intended to obtain widely defined risk indices from ECG monitoring: a simple-domain (heart rate turbulence (HRT)), and a complex-domain (heart rate variability (HRV)). Data provided by the three subdomains allowed for the generation of alerts with different intensity and nature, as well as for the grouping and scrutinization of patients according to the established processing and risk-thresholding criteria. The implemented system was tested by connecting data from real-world in-hospital electronic health records and ECG monitoring by considering standards for syntactic (HL7 messages) and semantic interoperability (archetypes based on CEN/ISO EN13606 and SNOMED-CT). The system was able to provide risk indices and to generate alerts in the health records to support decision-making. Overall, the system allows for the agile interaction of research and clinical practice in the Holter-ECG-based cardiac risk domain. PMID:29494497

  7. Cardiotoxicity in Asymptomatic Patients Receiving Adjuvant 5-fluorouracil

    DEFF Research Database (Denmark)

    Nielsen, Karin; Polk, Anne; Nielsen, Dorte Lisbet

    2014-01-01

    Evolving evidence of cardiotoxicity in cancer patients treated with 5-fluorouracil (5-FU) has been reported. We report two different clinical manifestations of asymptomatic 5-FU-associated cardiotoxicity in patients operated for colorectal cancer and treated with adjuvant chemotherapy of 5-FU...... (bolus-injection and continuous infusion for 46 hours), folinic acid and oxaliplatin (FOLFOX). For a research study evaluating cardiac events during 5-FU treatment, Holter monitoring, electrocardiogram (ECG) and echocardiography were done and cardiac markers monitored before and during the first...... and hyperlipidemia as well as an incidental finding of negative T-waves in electrocardiogram years before 5-FU treatment. No subjective cardiac symptoms were described during infusion, but approximately 12 hours after infusion she suffered from cardiac arrest but was revived. Subsequent analysis of the Holter...

  8. HEREDITARY INTRAVENTRICULAR CONDUCTION DISORDERS IN THE FAMILY FROM KRASNOYARSK

    Directory of Open Access Journals (Sweden)

    A. A. Chernova

    2011-01-01

    Full Text Available Pedigree of the family from Krasnoyarsk city with hereditary disorders of intracardiac conduction was studied. The diagnosis of each family member was verified by electrocardiography (ECG, echocardiography , bicycle ergometry , ECG Holter monitoring. The family 10-year follow-up showed familial aggregation of intracardiac conduction disorders in grandson, niece, son of the proband niece, ie, in the III-degree relatives. Family history of III-degree relatives with intracardiac conduction disorders and discordant pathology is identified.

  9. CONTINUOUS HOLTER MONITORING OF PATIENTS WITH CARDIOVASCULAR DISEASES IN ORAL SURGERY

    OpenAIRE

    Hristo Daskalov; Lyudmila Vladimirova-Kitova; F. Nikolov; E. Sarachev

    2011-01-01

    Introduction. Pain control and anxiety management are important aspects of modern dental treatment. Although many local anesthetics and anesthesia techniques have so far been studied, there is still no clarity as to what anesthetic should be used in cardiovascularly compromised patients. This anesthetic and its dosage should be very carefully chosen to achieve optimal effective pain control; the possible side effects occurring mainly in morbidly compromised patients should also be well studie...

  10. CONTINUOUS HOLTER MONITORING OF PATIENTS WITH CARDIOVASCULAR DISEASES IN ORAL SURGERY

    Directory of Open Access Journals (Sweden)

    Hristo Daskalov

    2011-09-01

    Full Text Available Introduction. Pain control and anxiety management are important aspects of modern dental treatment. Although many local anesthetics and anesthesia techniques have so far been studied, there is still no clarity as to what anesthetic should be used in cardiovascularly compromised patients. This anesthetic and its dosage should be very carefully chosen to achieve optimal effective pain control; the possible side effects occurring mainly in morbidly compromised patients should also be well studied.Methods. The aim of this study was to study the effect of vasoconstrictors on local anesthetics in 18 patients with heart diseases. The study contingent was recruited from the patients visiting often their general dental practitioners and diagnosed with the following heart diseases: Heart failure (after 6 months; ischemic heart disease, including mild angina pectoris. Articaine was used as local anesthetic. Results. The ST segment on the ECG was used to detect myocardial ischemia and to study the effect of the administered local anesthesia.Conclusion. The study results suggest that pain control in a cardiovascularly compromised patient subjected to oral surgery should be carried out only after thorough analysis is conducted of the specific condition and current status of the patient. Additional hematological tests shoud be done to enable the dentist to build a viable treatment plan.

  11. Ambulatory monitoring of blood pressure and pregnancy outcome in pregnant women with white coat hypertension in the third trimester of pregnancy.

    Science.gov (United States)

    Shahbazian, Nahid; Shahbazian, Heshmatollah; Mohammadjafari, Razieh; Mousavi, Mahsan

    2013-01-01

    Introduction: If the blood pressure of a pregnant woman is ≥140/90 mmHg at the clinic, but her ambulatory blood pressure is less coat hypertension. Objectives: To evaluate the value of ambulatory blood pressure monitoring in pregnant women. Patients and Methods: This prospective cohort study was conducted in Imam-Khomeini hospital of Ahwaz, Iran between 2011 to 2012. A total of 105 pregnant women who had blood pressure of higher than 140/90 mmHg during the third trimester of pregnancy were monitored. Thirty five women with white coat hypertension, 35 women with gestational hypertension and 35 women with normal blood pressure were followed. The data were analyzed using the Kolmogorov-Smirnov test, Pearson correlation coefficient and Chi-square tests. Results: The prevalence of white coat hypertension was 31.3%. The maternal and neonatal outcomes and laboratory examinations in white coat hypertension were similar to the normal blood pressure, but the frequency of caesarean section was more than the other two groups. Conclusion: The findings of the study indicate the efficacy of 24 hour holter monitoring of blood pressure and using it more comprehensively , compared to the limited visits.

  12. Cardiac asystole following cannabis (marijuana) usage--additional mechanism for sudden death?

    Science.gov (United States)

    Menahem, Samuel

    2013-12-10

    A 21 year old university student previously operated during infancy for an unobstructed total anomalous pulmonary venous drainage with an excellent result, was noted on a routine follow up 24 h Holter monitor to have multiple pauses related to cardiac asystole, the longest lasting 5.8 s and temporally related to marijuana inhalation. A repeat Holter was normal following a two week cessation of marijuana usage and again when carried out 3 months later. The documented periods of asystole may be a precursor of sudden death seen in addicts even without evidence of ischaemic heart disease. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Silent ischemia in patients after the acute myocardial infarction

    International Nuclear Information System (INIS)

    Samarzija, M.

    1991-01-01

    The purpose of this study was to determine the frequency and importance of silent ischemia in patients (pts) after acute myocardial infarction (AMI) as well as to establish diagnostic and prognostic values of exercise stress test (EST), Holter (H) monitoring and thallium-201 (Tl) scintigraphy. All the tests were performed 2-4 months following the AMI. The criterion for diagnostic myocardial ischemia on EST and H is 1 mm or more of horizontal or down-sloping ST depression. Additional criteria for Holter imply that the ischemic episode should last one minute and be separated from other episodes by at least one minute. Planar thallium images were performed 5-10 minutes after the stress test; the delayed images were obtained after 3-6 hours. Visual and quantitative methods were employed in the analysis of Tl-scintigraphy. Scintigraphy was considered positive if exercise-induced perfusion defects showed redistribution. The study included 74 asymptomatic patients after the AMI. The patients were divided into two groups by results of quantitative Tl-scintigraphy: Group I - 44 pts with silent ischemia, Group II - 30 pts without ischemia. In Group I, out of 44 pts, 9 had a positive exercise stress test, 4 showed a painless ST depression on Holter and 7 had both tests positive, whereas 24 pts had only scintigraphy positive. In Group II one patient had positive EST and H. Sensitivity and specificity were determined by results of coronary arteriography performed on 33 pts: EST (Se=40%, Sp=80%), H (Se=21%, Sp=100%) and scintigraphy (Se=93%, Sp=80%). During the follow-up period lasting at least 12 months, in Group I 3 pts died, 1 developed a new myocardial infarction and 15 pts had painful ischemic occurrences. In Group II only 3 pts developed symptoms of angina pectoris. Tl-scintigraphy was the only non-invasive test showing significant correlation with the follow-up outcomes. The diagnostic and prognostic superiority of Tl-scintigraphy justifies its value as an initial

  14. Silent ischemia in patients after uncomplicated myocardial infarction

    International Nuclear Information System (INIS)

    Samarzija, M.; Tezak, S.

    1994-01-01

    The purpose of this study was to determine the frequency and importance of silent ischemia in patients (pts) after the acute myocardial infarction (A MI) as well as to establish diagnostic and prognostic value of exercise stress test (EST), Holter (H) monitoring and thallium-201 (Tl) scintigraphy. All the three tests were performed 2-4 months following the AMI. The criterion for diagnosing myocardial ischemia on EST and H is 1 mm or more of horizontal or down-sloping ST depression. Additional criteria for Holter imply the ischemic episode should last one minute and be separated from other episodes by at least one minute. Planar thallium images were performed 5-10 minute after the stress test; the delayed images were obtained after 3-6 hours. Visual and quantitative methods were employed in the analysis of TI-scintigraphy. Scintigraphy was considered positive if exercise- induced perfusion defects showed redistribution. The study included 74 asymptomatic patients after the AMI. The patients were divided into two groups by results of quantitative Tl-scintigraphy: Group I - 44 pts with silent ischemia, Group II - 30 pts without ischemia. In Group I, out of 44 pts, 9 had a positive exercise stress, 4 showed a painless ST depression on Holter and 7 had both tests positive, whereas 24 pts had only scintigraphy positive. In Group II one patient had positive EST and H. Sensitivity and specificity were determined by results of coronary arteriography performed on 33 pts: EST (Se=40%, Sp=80%), H (Se=219, Sp=100%) and scintigraphy (Se=93%, Sp =80%). During the follow-up period lasting at least 12 months, in Group I 3 pts died, 1 developed a new myocardial infarction and 15 pts had painful ischemic occurrences. In Group II only 3 pts developed symptoms of angina pectoris. Tl-scintigraphy was the only non-invasive test showing significant correlation with the follow-up outcomes. The diagnostic and prognostic superiority of Tl-scintigraphy justifies its value as the initial

  15. Ventricular arrhythmia burst is an independent indicator of larger infarct size even in optimal reperfusion in STEMI

    NARCIS (Netherlands)

    van der Weg, Kirian; Majidi, Mohamed; Haeck, Joost D. E.; Tijssen, Jan G. P.; Green, Cynthia L.; Koch, Karel T.; Kuijt, Wichert J.; Krucoff, Mitchell W.; Gorgels, Anton P. M.; de Winter, Robbert J.

    2016-01-01

    We hypothesized that ventricular arrhythmia (VA) bursts during reperfusion phase are a marker of larger infarct size despite optimal epicardial and microvascular perfusion. 126 STEMI patients were studied with 24h continuous, 12-lead Holter monitoring. Myocardial blush grade (MBG) was determined and

  16. Use of left ventricular ejection fraction or wall-motion score index in predicting arrhythmic death in patients following an acute myocardial infarction. The TRACE Study Group

    DEFF Research Database (Denmark)

    Køber, L; Torp-Pedersen, C; Elming, H

    1997-01-01

    on the correlation between arrhythmic death and "sudden unexpected death" defined as death within 1 hour of onset of new symptoms. Assessment of late potentials, heart rate variability (HRV), T wave alternans, arrhythmias seen on Holter monitoring or during exercise testing, electrophysiological testing...

  17. Exposure assessment and heart rate variability monitoring in workers handling titanium dioxide particles: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Ichihara, Sahoko [Mie University, Graduate School of Regional Innovation Studies (Japan); Li, Weihua [WHO Collaborating Centre for Research in Human Reproduction, Shanghai Institute of Planned Parenthood Research (China); Omura, Seiichi [Tokyo Institute of Technology (Japan); Fujitani, Yuji [National Institute for Environmental Studies (Japan); Liu, Ying; Wang, Qiangyi [WHO Collaborating Centre for Research in Human Reproduction, Shanghai Institute of Planned Parenthood Research (China); Hiraku, Yusuke [Mie University Graduate School of Medicine, Department of Environmental and Molecular Medicine (Japan); Hisanaga, Naomi [Aichi Gakusen University, Faculty of Human Science and Design (Japan); Wakai, Kenji [Nagoya University Graduate School of Medicine, Department of Preventive Medicine (Japan); Ding, Xuncheng [WHO Collaborating Centre for Research in Human Reproduction, Shanghai Institute of Planned Parenthood Research (China); Kobayashi, Takahiro, E-mail: takakoba@airies.or.jp [Association for International Research Initiatives for Environmental Studies (Japan); Ichihara, Gaku, E-mail: gak@rs.tus.ac.jp [Tokyo University of Science, Department of Occupational and Environmental Health, Faculty of Pharmaceutical Sciences (Japan)

    2016-03-15

    Titanium dioxide (TiO{sub 2}) particles are used for surface coating and in a variety of products such as inks, fibers, food, and cosmetics. The present study investigated possible respiratory and cardiovascular effects of TiO{sub 2} particles in workers exposed to this particle at high concentration in a factory in China. The diameter of particles collected on filters was measured by scanning electron microscopy. Real-time size-dependent particle number concentration was monitored in the nostrils of four workers using condensation particle counter and optical particle counter. Electrocardiogram was recorded using Holter monitors for the same four workers to record heart rate variability. Sixteen workers underwent assessment of the respiratory and cardiovascular systems. Mass-based individual exposure levels were also measured with personal cascade impactors. The primary particle diameter ranged from 46 to 562 nm. Analysis of covariance of the pooled data of the four workers showed that number of particles with a diameter <300 nm was associated positively with total number of N–N and negatively with total number of increase or decrease in successive RR intervals greater than 50 ms (RR50+/−) or percentage of RR 50+/− that were parameters of parasympathetic function. The total mass concentration was 9.58–30.8 mg/m{sup 3} during work, but significantly less before work (0.36 mg/m{sup 3}). The clear abnormality in respiratory function was not observed in sixteen workers who had worked for 10 months to 13 years in the factory. The study showed that exposure to particles with a diameter <300 nm might affect HRV in workers handling TiO{sub 2} particles. The results highlight the need to investigate the possible impact of exposure to nano-scaled particles on the autonomic nervous system.

  18. Complete paroxysmal atrioventricular block in a 2-year-old girl

    DEFF Research Database (Denmark)

    Holst, Line Marie; Dixen, Ulrik; Jeppesen, Dorthe L

    2015-01-01

    We present a case of atypical syncope in a 2-year-old, otherwise healthy girl. The patient presented with three episodes of syncope without any precipitating factors and no family history of sudden unexpected death. Holter monitoring revealed 24 events of complete atrioventricular block lasting up...

  19. Clinical experience in extended cardiac monitoring with the SEEQ™ satellite wireless system

    Directory of Open Access Journals (Sweden)

    Diego Vanegas-Cadavid

    2018-05-01

    Full Text Available Objectives: To present the clinical experience with a new extended (for 15 days, wireless, and satellite cardiac monitoring system in a group of patients with suspicion of cardiac arrhythmia. Method: The study included a cohort of 100 patients seen in the Cardiovascular Electrophysiology Unit of a reference hospital. They were suspected of having a cardiac arrhythmia, with no electrocardiographic diagnosis of the cause, despite previous examinations. They were subjected to SEEQ-type (Medtronic external cardiac monitoring for 15 days, with the outcomes recorded. Results: Of the total of 100 subjects studied, 51% were male, and the median age was 60 years (range: 5 - 91 years. The main symptoms were palpitation, and the most prevalent comorbidity was arterial hypertension (47%. Almost all (98% of them had a previous Holter study, and 46% had two studies, which were inconclusive in explaining the symptoms. The SEEQ monitoring recorded a significant electrocardiographic abnormality in 22% of the patients. A pacemaker implant was the treatment most applied and atrial fibrillation was the most frequent arrhythmia in 50% of the positive findings. There was a higher and significant percentage of positive diagnoses in males. Conclusions: External, satellite, wireless cardiac monitoring extended for 15 days, is a novel tool that can increase the probability of documenting a clinically significant electrocardiographic abnormality in those patients who suffer recurrent cardiovascular symptoms. Resumen: Objetivos: Dar a conocer la experiencia clínica con un nuevo sistema de monitorización cardiaca extendida (por 15 días, inalámbrica y satelital en un grupo de pacientes con sospecha de arritmias cardíacas. Metodología: Cohorte de 100 pacientes atendidos en la unidad de Electrofisiología cardiovascular de un centro de referencia, con sospecha de arritmia cardíaca, sin diagnóstico electrocardiográfico causal, a pesar de exámenes previos. Se les aplic

  20. A Unique Digital Electrocardiographic Repository for the Development of Quantitative Electrocardiography and Cardiac Safety: The Telemetric and Holter ECG Warehouse (THEW)

    Science.gov (United States)

    Couderc, Jean-Philippe

    2010-01-01

    The sharing of scientific data reinforces open scientific inquiry; it encourages diversity of analysis and opinion while promoting new research and facilitating the education of next generations of scientists. In this article, we present an initiative for the development of a repository containing continuous electrocardiographic information and their associated clinical information. This information is shared with the worldwide scientific community in order to improve quantitative electrocardiology and cardiac safety. First, we present the objectives of the initiative and its mission. Then, we describe the resources available in this initiative following three components: data, expertise and tools. The Data available in the Telemetric and Holter ECG Warehouse (THEW) includes continuous ECG signals and associated clinical information. The initiative attracted various academic and private partners whom expertise covers a large list of research arenas related to quantitative electrocardiography; their contribution to the THEW promotes cross-fertilization of scientific knowledge, resources, and ideas that will advance the field of quantitative electrocardiography. Finally, the tools of the THEW include software and servers to access and review the data available in the repository. To conclude, the THEW is an initiative developed to benefit the scientific community and to advance the field of quantitative electrocardiography and cardiac safety. It is a new repository designed to complement the existing ones such as Physionet, the AHA-BIH Arrhythmia Database, and the CSE database. The THEW hosts unique datasets from clinical trials and drug safety studies that, so far, were not available to the worldwide scientific community. PMID:20863512

  1. A low-power and miniaturized electrocardiograph data collection system with smart textile electrodes for monitoring of cardiac function.

    Science.gov (United States)

    Dai, Ming; Xiao, Xueliang; Chen, Xin; Lin, Haoming; Wu, Wanqing; Chen, Siping

    2016-12-01

    With the increasing aging population as well as health concerns, chronic heart disease has become the focus of public attention. A comfortable, low-powered, and wearable electrocardiogram (ECG) system for continuously monitoring the elderly's ECG signals over several hours is important for preventing cardiovascular diseases. Traditional ECG monitoring apparatus is often inconvenient to carry, has many electrodes to attach to the chest, and has a high-power consumption. There is also a challenge to design an electrocardiograph that satisfies requirements such as comfort, confinement, and compactness. Based on these considerations, this study presents a biosensor acquisition system for wearable, ubiquitous healthcare applications using three textile electrodes and a recording circuit specialized for ECG monitoring. In addition, several methods were adopted to reduce the power consumption of the device. The proposed system is composed of three parts: (1) an ECG analog front end (AFE), (2) digital signal processing and micro-control circuits, and (3) system software. Digital filter methods were used to eliminate the baseline wander, skin contact noise, and other interfering signals. A comparative study was conducted using this system to observe its performance with two commercial Holter monitors. The experimental results demonstrated that the total power consumption of this proposed system in a full round of ECG acquisition was only 29.74 mW. In addition, this low-power system performed well and stably measured the heart rate with an accuracy of 98.55 %. It can also contain a real-time dynamic display with organic light-emitting diodes (OLED) and wirelessly transmit information via a Bluetooth 4.0 module.

  2. Prosthetic Valve Endocarditis - Successful Management With Antimicrobial Treatment

    Directory of Open Access Journals (Sweden)

    Ashokan Nambiar C

    2015-07-01

    Full Text Available Middle aged male was admitted with high fever, rigor and chills of 2 days duration. He was seen in the clinic two years back for syncope. He gave history of Mitral (Starr-Edward and Aortic (Medtronic valve replacement ten years earlier from another center and was on regular anticoagulation with dose-adjusted acenocoumarol. On evaluation he had normal prosthetic valve function by trans-thoracic echo, but Holter monitoring showed Paroxysmal Atrial Fibrillation. He had mild wall motion abnormalities and left ventricular dysfunction suggestive of coronary artery disease also and was put on additional Metoprolol.

  3. Perfil clínico de pacientes chagásicos e não-chagásicos portadores de marca-passo cardíaco artificial Clinical profile of Chagas and non-Chagas' disease patients with cardiac pacemaker

    Directory of Open Access Journals (Sweden)

    Leonor Garcia Rincon

    2006-06-01

    Full Text Available O objetivo do estudo foi comparar pacientes chagásicos e não-chagásicos com marca-passo cardíaco artificial uni ou bicameral quanto à fração de ejeção do ventrículo esquerdo, o limiar de estimulação ventricular e a incidência de arritmias cardíacas. Entre janeiro/2001 e novembro/2002 foram avaliados 45 pacientes chagásicos e 35 não-chagásicos portadores de marca-passo quanto à história clínica, radiografia do tórax, ecocardiograma, Holter 24h e análise telemétrica do marca-passo. Embora os chagásicos fossem mais jovens, os dois grupos foram semelhantes quanto a variáveis radiológicas e o limiar de estimulação ventricular direito. Os chagásicos apresentaram menor fração de ejeção do ventrículo esquerdo ao ecocardiograma e maior incidência de arritmia ventricular ao Holter 24h. Observou-se correlação positiva entre a baixa fração de ejeção do ventrículo esquerdo e a intensidade da arritmia ventricular ao Holter 24h. Em pacientes com marca-passo, a doença de Chagas está associada a marcadores cardíacos de prognóstico adverso.The aim of this study was to compare Chagas and non-Chagas' disease patients using single or dual-chamber pacemaker in relation to the ejection fraction of the left ventricle, the ventricular stimulation threshold and the occurrence of ventricular arrhythmia. From January, 2001 to November, 2002, 45 Chagas' disease patients and 35 non-Chagas' disease patients, all pacemaker users, were evaluated considering clinical history, echocardiographic study, Holter monitoring and analysis of the pacemaker telemetry data. Chagas' disease patients were significantly younger, but both groups were similar when chest X-Ray variables and right ventricular stimulation threshold were analyzed. Chagas' disease patients had a lower left ventricular ejection fraction and more frequent ventricular arrhythmia during Holter monitoring. A positive correlation between the low ejection fraction of the left

  4. Atrial fibrillation is not uncommon among patients with ischemic stroke and transient ischemic stroke in China.

    Science.gov (United States)

    Yang, Xiaomeng; Li, Shuya; Zhao, Xingquan; Liu, Liping; Jiang, Yong; Li, Zixiao; Wang, Yilong; Wang, Yongjun

    2017-12-04

    Atrial fibrillation (AF) is reported to be a less frequent cause of ischemic stroke in China than in Europe and North America, but it is not clear whether this is due to underestimation. Our aim was to define the true frequency of AF-associated stroke, to determine the yield of 6-day Holter ECG to detect AF in Chinese stroke patients, and to elucidate predictors of newly detected AF. Patients with acute ischemic stroke or transient ischemic attack (TIA) were enrolled in a prospective, multicenter cohort study of 6-day Holter monitoring within 7 days after stroke onset at 20 sites in China between 2013 and 2015. Independent predictors of newly-detected AF were determined by multivariate analysis. Among 1511 patients with ischemic stroke and TIA (mean age 63 years, 33.1% women), 305 (20.2%) had either previously known (196, 13.0%) or AF newly-detected by electrocardiography (53, 3.5%) or by 6-day Holter monitoring (56/1262, 4.4%). A history of heart failure (OR = 4.70, 95%CI, 1.64-13.5), advanced age (OR = 1.06, 95%CI, 1.04-1.09), NIHSS at admission (OR = 1.06, 95%CI, 1.02-1.10), blood high density lipoprotein (HDL) (OR = 1.52, 95%CI, 1.09-2.13), together with blood triglycerides (OR = 0.64, 95%CI, 0.45-0.91) were independently associated with newly-detected AF. Contrary to previous reports, AF-associated stroke is frequent (20%) in China if systemically sought. Prolonged noninvasive cardiac rhythm monitoring importantly increases AF detection in patients with recent ischemic stroke and TIA in China. Advanced age, history of heart failure, and higher admission NIHSS and higher level of HDL were independent indicators of newly-detected AF. NCT02156765 (June 5, 2014).

  5. Current investigation and management of patients with syncope

    DEFF Research Database (Denmark)

    Dagres, Nikolaos; Bongiorni, Maria Grazia; Dobreanu, Dan

    2013-01-01

    and indications for tilt table testing in neurally mediated syncope. The majority of centres reported using ECG, echocardiography, and Holter monitoring as their main diagnostic tools in patients with syncope, whereas a smaller proportion of centres applied specific assessment algorithms. Physical manoeuvres were...... almost uniformely reported as the standard treatment for neurally mediated syncope....

  6. Syncope in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    I. V. Leontyeva

    2014-01-01

    Full Text Available Seventy children aged 7 to 17 years with hypertrophic cardiomyopathy (HCM were examined; among them there were 11 syncope patients and 5 presyncope patients. The screening program included standard electrocardiography (ECG, Doppler echocardiogra-phy, 24-hour Holter ECG monitoring, and an incremental exercise testing (Bruce treadmill test. The markers of myocardial electrical instability were determined. In the children with HCM, syncope was established to be heterogeneous; it had an arrhythmogenic origin and, in most cases, occurred in the presence of tachyarrhythmia (44% or bradyarrythmia (25%; its vasovagal genesis was probable in one third of the examinees. The children with syncope were typified by the asymmetric, obstructive form of HCM, at the same tone there was most commonly left ventricular hypertrophy concurrent with left atrial enlargement. 24-hour Holter monitoring showed that bradycardia was prevalent in the patients, 3 patients were found to have more than 2-second cardiac rhythm pauses caused by second-degree atrioventricular block in 1 case or by sick sinus syndrome in 2. Nonsustained ventricular tachycardia was noted in two patients. The children with syncope were typified by the signs of myocardial electrical instability as a reduction in the early phase of heart rate turbulence and by impaired QT/RR interval adaptation as hyperadaptation. The paper presents the developed management tactics for children with syncope and indications for the implantation of a cardioverter defibrillator, a pacemaker, or an ECG loop recorder.

  7. Multimodality assessment of cardiac involvement in Churg-Strauss syndrome patients in clinical remission

    International Nuclear Information System (INIS)

    Szczeklik, W.; Miszalski-Jamka, T.; Mastalerz, L.; Sokolowska, B.; Dropinski, J.; Musial, J.; Banys, R.; Hor, K.N.; Mazur, W.

    2011-01-01

    Cardiac involvement in Churg-Strauss syndrome (CSS) is not uncommon, but its frequency varies widely and may depend on the activity of the disease. Therefore, the cardiac involvement in CSS patients in clinical remission was assessed in the present study. In 20 CSS patients in remission and 20 sex- and age-matched healthy controls, an electrocardiogram (ECG) stress test, echocardiography, and 24-h ECG Holter monitoring were performed, together with cardiac magnetic resonance imaging (cMRI). Cardiac involvement was present in 90% (18/20) of CSS patients. Left ventricular ejection fraction (LVEF) was on average lower in the CSS group than in controls (P<0.05), with 7 patients showing systolic heart failure (LVEF <50%). cMRI changes included late gadolinium enhancement lesions in the LV in 89% of patients (17/19), present in all layers of the myocardium. Signs of ongoing inflammation (early gadolinium enhancement) and edema (T2-weighted imaging) were present in 6/19 patients. Holter monitoring revealed both supraventricular and ventricular arrhythmias more frequently in CSS patients when compared with controls (P<0.05). Absolute eosinophil count before the initiation of treatment was higher in rhythm disturbances (P<0.05), and inversely correlated with LV systolic function (rho -0.65). Heart involvement in CSS patients who are in clinical remission is very common. It is characterized not only by fibrosis, but also by an active inflammatory process. The latter finding might influence therapeutic decisions in CSS patients in full clinical remission. (author)

  8. Multimodality assessment of cardiac involvement in Churg-Strauss syndrome patients in clinical remission

    Energy Technology Data Exchange (ETDEWEB)

    Szczeklik, W; Miszalski-Jamka, T; Mastalerz, L; Sokolowska, B; Dropinski, J; Musial, J [Medical Coll., Jagiellonian Univ., Krakow (Poland); Banys, R [John Paul II Hospital, Krakow (Poland); Hor, K N [Cincinnati Children' s Medical Center, OH (United States); Mazur, W [Heart and Vascular Center at The Christ Hospitals, OH (United States)

    2011-02-15

    Cardiac involvement in Churg-Strauss syndrome (CSS) is not uncommon, but its frequency varies widely and may depend on the activity of the disease. Therefore, the cardiac involvement in CSS patients in clinical remission was assessed in the present study. In 20 CSS patients in remission and 20 sex- and age-matched healthy controls, an electrocardiogram (ECG) stress test, echocardiography, and 24-h ECG Holter monitoring were performed, together with cardiac magnetic resonance imaging (cMRI). Cardiac involvement was present in 90% (18/20) of CSS patients. Left ventricular ejection fraction (LVEF) was on average lower in the CSS group than in controls (P<0.05), with 7 patients showing systolic heart failure (LVEF <50%). cMRI changes included late gadolinium enhancement lesions in the LV in 89% of patients (17/19), present in all layers of the myocardium. Signs of ongoing inflammation (early gadolinium enhancement) and edema (T2-weighted imaging) were present in 6/19 patients. Holter monitoring revealed both supraventricular and ventricular arrhythmias more frequently in CSS patients when compared with controls (P<0.05). Absolute eosinophil count before the initiation of treatment was higher in rhythm disturbances (P<0.05), and inversely correlated with LV systolic function (rho -0.65). Heart involvement in CSS patients who are in clinical remission is very common. It is characterized not only by fibrosis, but also by an active inflammatory process. The latter finding might influence therapeutic decisions in CSS patients in full clinical remission. (author)

  9. Early and late arrhythmogenic effects of doxorubicin.

    Science.gov (United States)

    Kilickap, Saadettin; Barista, Ibrahim; Akgul, Ebru; Aytemir, Kudret; Aksoy, Sercan; Tekuzman, Gulten

    2007-03-01

    To determine the incidence of early and late arrhythmogenic effects of doxorubicin-containing chemotherapy regimens. A prospective study including 29 patients who were treated with doxorubicin-containing regimens. Cardiac evaluation was based on 24-hour electrocardiographic monitorization (Holter), which was performed during the first cycle of doxorubicin-containing regimens, as well as after the last cycle of chemotherapy. The mean age of the patients was 45.8 +/- 15.1 (range 18-69). Holter records obtained during the first cycle of treatment revealed varying arrhythmias in 19 patients (65.5%) and in 18 (62.1%) patients after completion of therapy. One patient presented with syncope and both Mobitz Type 2 atrioventricular block and complete atrioventricular block were demonstrated. The patient subsequently underwent permanent pacemaker implantation. Doxorubicin may result in arrhythmias both in early and late periods of treatment. These arrhythmias are rarely life threatening.

  10. Eccentric apical hypertrophic cardiomyopathy unmasked by multimodality imaging: an uncommon but missed cause of out of hospital cardiac arrest

    Science.gov (United States)

    Towe, Eric; Sharma, Saurabh; Geske, Jeffrey; Ackerman, Michael J

    2015-01-01

    A woman in her late 50s experienced a witnessed, sudden out of hospital cardiac arrest. Initial workup included coronary angiography, transthoracic echocardiogram and a CT scan of the chest to rule out pulmonary embolus. She was subsequently discharged home without an implantable cardioverter defibrillator (ICD) or a life vest. On follow-up at another facility, an ICD was placed and a Holter monitor showed no ventricular ectopy. Further transthoracic echocardiographic images were obtained, which were suggestive of apical hypertrophic cardiomyopathy. A limited transthoracic echocardiogram with contrast was performed, which did not elucidate the hypertrophy. However, eccentric left ventricular apical wall hypertrophy was visualised by a coronary CT scan. PMID:26153133

  11. α-Glucosidase inhibitor miglitol attenuates glucose fluctuation, heart rate variability and sympathetic activity in patients with type 2 diabetes and acute coronary syndrome: a multicenter randomized controlled (MACS) study.

    Science.gov (United States)

    Shimabukuro, Michio; Tanaka, Atsushi; Sata, Masataka; Dai, Kazuoki; Shibata, Yoshisato; Inoue, Yohei; Ikenaga, Hiroki; Kishimoto, Shinji; Ogasawara, Kozue; Takashima, Akira; Niki, Toshiyuki; Arasaki, Osamu; Oshiro, Koichi; Mori, Yutaka; Ishihara, Masaharu; Node, Koichi

    2017-07-06

    Little is known about clinical associations between glucose fluctuations including hypoglycemia, heart rate variability (HRV), and the activity of the sympathetic nervous system (SNS) in patients with acute phase of acute coronary syndrome (ACS). This pilot study aimed to evaluate the short-term effects of glucose fluctuations on HRV and SNS activity in type 2 diabetes mellitus (T2DM) patients with recent ACS. We also examined the effect of suppressing glucose fluctuations with miglitol on these variables. This prospective, randomized, open-label, blinded-endpoint, multicenter, parallel-group comparative study included 39 T2DM patients with recent ACS, who were randomly assigned to either a miglitol group (n = 19) or a control group (n = 20). After initial 24-h Holter electrocardiogram (ECG) (Day 1), miglitol was commenced and another 24-h Holter ECG (Day 2) was recorded. In addition, continuous glucose monitoring (CGM) was performed throughout the Holter ECG. Although frequent episodes of subclinical hypoglycemia (≤4.44 mmo/L) during CGM were observed on Day 1 in the both groups (35% of patients in the control group and 31% in the miglitol group), glucose fluctuations were decreased and the minimum glucose level was increased with substantial reduction in the episodes of subclinical hypoglycemia to 7.7% in the miglitol group on Day 2. Holter ECG showed that the mean and maximum heart rate and mean LF/HF were increased on Day 2 in the control group, and these increases were attenuated by miglitol. When divided 24-h time periods into day-time (0700-1800 h), night-time (1800-0000 h), and bed-time (0000-0700 h), we found increased SNS activity during day-time, increased maximum heart rate during night-time, and glucose fluctuations during bed-time, which were attenuated by miglitol treatment. In T2DM patients with recent ACS, glucose fluctuations with subclinical hypoglycemia were associated with alterations of HRV and SNS activity, which were mitigated by

  12. Visual working memory and threat monitoring: Spider fearfuls show disorder-specific change detection

    NARCIS (Netherlands)

    Reinecke, A.; Becker, E.S.; Rinck, M.

    2010-01-01

    Previous studies of biased information processing in anxiety addressed biases of attention and memory, but little is known about the processes taking place between them: visual working memory (VWM) and monitoring of threat. We investigated these processes with a change detection paradigm. In

  13. Buerger's Disease and Anaesthesia: The Neglected Cardiac Angle

    Directory of Open Access Journals (Sweden)

    Shagun Bhatia Shah

    2015-08-01

    Full Text Available Distal limb amputations and respiratory complications are common in patients with Buerger’s disease. Nicotine in cigarette is arrhythmogenic as it blocks cardiac potassium channels. Preoperative Holter ECG monitoring may be useful if preoperative electrocardiogram is normal. If the patient is undergoing major surgery, preservative free lignocaine & amiodarone infusions and a cardioverter defibrillator should be available for the intraoperative cardiac rhythm disturbances.

  14. Noise Maps for Quantitative and Clinical Severity Towards Long-Term ECG Monitoring.

    Science.gov (United States)

    Everss-Villalba, Estrella; Melgarejo-Meseguer, Francisco Manuel; Blanco-Velasco, Manuel; Gimeno-Blanes, Francisco Javier; Sala-Pla, Salvador; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2017-10-25

    Noise and artifacts are inherent contaminating components and are particularly present in Holter electrocardiogram (ECG) monitoring. The presence of noise is even more significant in long-term monitoring (LTM) recordings, as these are collected for several days in patients following their daily activities; hence, strong artifact components can temporarily impair the clinical measurements from the LTM recordings. Traditionally, the noise presence has been dealt with as a problem of non-desirable component removal by means of several quantitative signal metrics such as the signal-to-noise ratio (SNR), but current systems do not provide any information about the true impact of noise on the ECG clinical evaluation. As a first step towards an alternative to classical approaches, this work assesses the ECG quality under the assumption that an ECG has good quality when it is clinically interpretable. Therefore, our hypotheses are that it is possible (a) to create a clinical severity score for the effect of the noise on the ECG, (b) to characterize its consistency in terms of its temporal and statistical distribution, and (c) to use it for signal quality evaluation in LTM scenarios. For this purpose, a database of external event recorder (EER) signals is assembled and labeled from a clinical point of view for its use as the gold standard of noise severity categorization. These devices are assumed to capture those signal segments more prone to be corrupted with noise during long-term periods. Then, the ECG noise is characterized through the comparison of these clinical severity criteria with conventional quantitative metrics taken from traditional noise-removal approaches, and noise maps are proposed as a novel representation tool to achieve this comparison. Our results showed that neither of the benchmarked quantitative noise measurement criteria represent an accurate enough estimation of the clinical severity of the noise. A case study of long-term ECG is reported

  15. Features of conngestive heart failure development in patients with post infarct cardiosclerosis concomitant with arrhythmias

    International Nuclear Information System (INIS)

    Zharov, E.I.; Martynov, A.I.; Vertkin, A.L.; Sergeeva, L.I.; Sedov, V.P.

    1989-01-01

    Two hundred and seventy seven patients with coronary heart disease, includng 182 with postinfarction cardiosclerosis undewent 24-hour Holter monitoring. A significant correlation was found between the number of coupled ventricular arrhythmias, ventricular tachycardia paroxysms and developmet of congestive heart failure in patients with postinfarct cardiosclerosis. With evolving metabolic deficiency as evidenced by thallium-201 myocardial scintigraphy, the incidence of congestive heart failure and ventricular arrhythmias increased among the patients

  16. A wearable smartphone-based platform for real-time cardiovascular disease detection via electrocardiogram processing.

    Science.gov (United States)

    Oresko, Joseph J; Duschl, Heather; Cheng, Allen C

    2010-05-01

    Cardiovascular disease (CVD) is the single leading cause of global mortality and is projected to remain so. Cardiac arrhythmia is a very common type of CVD and may indicate an increased risk of stroke or sudden cardiac death. The ECG is the most widely adopted clinical tool to diagnose and assess the risk of arrhythmia. ECGs measure and display the electrical activity of the heart from the body surface. During patients' hospital visits, however, arrhythmias may not be detected on standard resting ECG machines, since the condition may not be present at that moment in time. While Holter-based portable monitoring solutions offer 24-48 h ECG recording, they lack the capability of providing any real-time feedback for the thousands of heart beats they record, which must be tediously analyzed offline. In this paper, we seek to unite the portability of Holter monitors and the real-time processing capability of state-of-the-art resting ECG machines to provide an assistive diagnosis solution using smartphones. Specifically, we developed two smartphone-based wearable CVD-detection platforms capable of performing real-time ECG acquisition and display, feature extraction, and beat classification. Furthermore, the same statistical summaries available on resting ECG machines are provided.

  17. Noninvasive diagnosis of allograft vascular disease after heart transplantation

    Directory of Open Access Journals (Sweden)

    Fernando Bacal

    2001-01-01

    Full Text Available OBJECTIVE: To determine the predictive values of noninvasive tests for the detection of allograft vascular disease. METHODS: We studied 39 patients with mean ages of 48±13 years and a follow-up period of 86±13 months. The diagnosis of allograft vascular disease was made by cine-coronary arteriography, and it was considered as positive if lesions existed that caused > or = 50% obstruction of the lumen. Patients underwent 24h Holter monitoring, thallium scintigraphy, a treadmill stress test, and dobutamine stress echocardiography. Sensitivity, specificity, and positive and negative predictive values were determined in percentages for each method, as compared with the cine-coronary arteriography results. RESULTS: Allograft vascular disease was found in 15 (38% patients. The Holter test showed 15.4% sensitivity, 95.5% specificity. For the treadmill stress test, sensitivity was 10%, specificity was 100%. When thallium scintigraphy was used, sensitivity was 40%, specificity 95.8%. On echocardiography with dobutamine, we found a 63.6% sensitivity, 91.3% specificity. When the dobutamine echocardiogram was associated with scintigraphy, sensitivity was 71.4%, specificity was 87%. CONCLUSION: In this group of patients, the combination of two noninvasive methods (dobutamine echocardiography and thallium scintigraphy may be a good alternative for the detection of allograft vascular disease in asymptomatic patients with normal ventricular function.

  18. Impaired chronotropic response to physical activities in heart failure patients.

    Science.gov (United States)

    Shen, Hong; Zhao, Jianrong; Zhou, Xiaohong; Li, Jingbo; Wan, Qing; Huang, Jing; Li, Hui; Wu, Liqun; Yang, Shungang; Wang, Ping

    2017-05-25

    While exercise-based cardiac rehabilitation has a beneficial effect on heart failure hospitalization and mortality, it is limited by the presence of chronotropic incompetence (CI) in some patients. This study explored the feasibility of using wearable devices to assess impaired chronotropic response in heart failure patients. Forty patients with heart failure (left ventricular ejection fraction, LVEF: 44.6 ± 5.8; age: 54.4 ± 11.7) received ECG Holter and accelerometer to monitor heart rate (HR) and physical activities during symptom-limited treadmill exercise testing, 6-min hall walk (6MHW), and 24-h daily living. CI was defined as maximal HR during peak exercise testing failing to reach 70% of age-predicted maximal HR (APMHR, 220 - age). The correlation between HR and physical activities in Holter-accelerometer recording was analyzed. Of 40 enrolled patients, 26 were able to perform treadmill exercise testing. Based on exercise test reports, 13 (50%) of 26 patients did not achieve at least 70% of APMHR (CI patients). CI patients achieved a lower % APMHR (62.0 ± 6.3%) than non-CI patients who achieved 72.0 ± 1.2% of APMHR (P failure patients who took treadmill exercise testing. The wearable Holter-accelerometer recording could help to identify impaired chronotropic response to physical activities in heart failure patients. ClinicalTrials.gov ID NCT02358603 . Registered 16 May 2014.

  19. Comprehensive monitoring system - essential tool to show the results of the energy audit and voluntary agreement programmes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    Without visible results political support to an energy efficiency programme will dissolve in a few years. Therefore high-quality monitoring and reporting systems are essential to maintain a long-term commitment. Both in Finnish Energy Audit Programme (EAP), began in 1992, and in Voluntary Agreement Scheme (VA), began in 1997, bottom-up monitoring systems have been in place almost since the beginning. These policy measures and their monitoring systems are integrated. For the EAP monitoring system data is collected in three phases: subsidies granted; the energy auditing volumes in different sectors submitted EA reports; proposed measures and saving potentials. VA annual reporting; status of implementation of the proposed measures in EA reports and implementing rate for saving potentials. In VA scheme the companies and communities report annually on their energy consumption and on energy efficiency measures they have implemented or have decided to implement. Information on energy savings in energy units and energy costs as well as the required investment is reported in connection to the presented measures. The collected data is based on engineering calculations by the energy auditors. Since the companies have no incentives to submit exaggerated savings, the reported savings are equal to those figures the companies have used as criteria when deciding on the implementation of the measures. By 2005 these two policy measures have generated about 7 TWh annual savings, representing over 2 % of Finland's total energy end-use. In relation to the magnitude of savings brought in daylight, the investment on monitoring has really paid back.

  20. Further contribution to the development of nuclear stethoscopic techniques

    International Nuclear Information System (INIS)

    Horvath, M.; Nemeth, L.; Kantor, E.; Kiss, J.; Bocsa, Z.; Sziberth, P.; Karman, M.

    1991-01-01

    After the introduction of radiocardiography (RCG) function analysis, the method has gradually been improved by applying scintillation probes, semiconductor detectors and computer evaluation. Miniature semiconductor detectors were fixed onto the chest, the detection efficiency and energy resolution was clarified to further improve the RCG technique. Various semiconductor devices were tested and compared. The RCG was combined with Holter monitoring and ECG. Photodiode RCG was extended to ergometric measurements. These new improvements were evaluated. (R.P.) 8 refs.; 8 figs

  1. A Psychological Factor Affecting a Cardiac Condition in a Psychotherapist

    OpenAIRE

    R Waxman; K Khorasani; A Lenny; S Bhalerao

    2009-01-01

    It has been established that intense emotions can affect the development and course of cardiac arrhythmias. This study sought to convey that a lack of expression of emotion can also have an effect on arrhythmias. A psychotherapist with Idiopathic Ventricular Fibrillation and an Implantable Cardioverter Defibrillator measured his rate of Premature Ventricular Contractions using a Holter monitor during three separate six-week periods and in three domains: A) work days vs. off days, B) a 27 hour...

  2. Arrhythmia as a cardiac manifestation in MELAS syndrome.

    Science.gov (United States)

    Thomas, Tamara; Craigen, William J; Moore, Ryan; Czosek, Richard; Jefferies, John L

    2015-09-01

    A 44-year-old female with a diagnosis of mitochondrial myopathy, encephalopathy and stroke-like episodes (MELAS) syndrome had progressive left ventricular hypertrophy (LVH) on echocardiogram. A Holter monitor demonstrated episodes of non-sustained atrial tachycardia, a finding not been previously described in this population. This unique case of MELAS syndrome demonstrates the known associated cardiac manifestation of LVH and the new finding of atrial tachycardia which may represent the potential for subclinical arrhythmia in this population.

  3. Heart rate variability in healthy population

    International Nuclear Information System (INIS)

    Alamgir, M.; Hussain, M.M.

    2010-01-01

    Background: Heart rate variability has been considered as an indicator of autonomic status. Little work has been done on heart rate variability in normal healthy volunteers. We aimed at evolving the reference values of heart rate variability in our healthy population. Methods: Twenty-four hour holter monitoring of 37 healthy individuals was done using Holter ECG recorder 'Life card CF' from 'Reynolds Medical'. Heart rate variability in both time and frequency domains was analysed with 'Reynolds Medical Pathfinder Digital/700'. Results: The heart rate variability in normal healthy volunteers of our population was found in time domain using standard deviation of R-R intervals (SDNN), standard deviation of average NN intervals (SDANN), and Square root of the mean squared differences of successive NN intervals (RMSSD). Variation in heart rate variability indices was observed between local and foreign volunteers and RMSSD was found significantly increased (p<0.05) in local population. Conclusions: The values of heart rate variability (RMSSD) in healthy Pakistani volunteers were found increased compared to the foreign data reflecting parasympathetic dominance in our population. (author)

  4. Conventional heart rate variability analysis of ambulatory electrocardiographic recordings fails to predict imminent ventricular fibrillation

    Science.gov (United States)

    Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.

    1993-01-01

    OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.

  5. Occupational monitoring program

    International Nuclear Information System (INIS)

    Sordi, G.-M.A.A.

    1988-10-01

    After to give the principal aim of a monitoring program it gives the philosophy in force in our country and the new one, international. It shows the different monitoring types and the classification related to their functions. The functions are deal with, separately, for workplace and individual monitoring. It shows, also, that the individual monitoring can be used to assess the workplace conditions. It discusses the models that can be introduced to assess the quantities used in the results interpretation from the quantities used in the measurements. It gives an example. Finally it discusses the supplementary functions of monitoring as such reassessment of monitoring programs, selection of the controlled areas and the extent form of medical supervision. (author) [pt

  6. Useful clinical features for the selection of ideal patients with strial fibrillation for mapping and catheter ablation

    Directory of Open Access Journals (Sweden)

    Mehta Niraj

    2002-01-01

    Full Text Available OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1 antiarrhythmic drugs, 2 symptoms of low cardiac output, and 3 intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation, catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein. One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.

  7. Utility of heart rate turbulence and T-Wave alternans to assess risk for Re-admission and cardiac death in hospitalized heart failure patients.

    Science.gov (United States)

    Yamada, Shinya; Yoshihisa, Akiomi; Sato, Yu; Sato, Takamasa; Kamioka, Masashi; Kaneshiro, Takashi; Oikawa, Masayoshi; Kobayashi, Atsushi; Suzuki, Hitoshi; Ishida, Takafumi; Takeishi, Yasuchika

    2018-05-18

    Heart failure (HF) patients have a higher risk of recurrent HF and cardiac death, and electrical remodeling is considered to be an important factor for HF progression. The present study aimed to validate the utility of electrocardiogram and Holter monitoring for the risk stratification of HF patients. Our study comprised 215 patients (144 males, mean age 62 years) who had been hospitalized due to acute decompensated HF. Electrocardiogram (QRS duration and QTc interval) and 24-hour Holter monitoring (heart rate variability, heart rate turbulence and T-wave alternans [TWA]) were performed in stable condition before discharge. The clinical characteristics and outcomes were then investigated. During a median follow-up period of 2.7 years, there were 83 (38.6%) cardiac events (re-hospitalization due to worsening HF [n = 51] or cardiac death [n = 32]). The patients with cardiac events had a lower turbulence slope (TS) and higher TWA compared to those without cardiac events (TS, 3.0±5.5 ms/RR vs. 5.3±5.6 ms/RR, P = 0.001; TWA, 66.1±19.6 μV vs. 54.7±15.1 μV, P < 0.001). Univariable analysis showed that TS, TWA, QRS duration, and QTc interval were associated with cardiac events (P = 0.004, P < 0.001, P = 0.037 and P = 0.024, respectively), while the multivariable analysis after the adjustment of multiple confounders showed that TS and TWA were independent predictive factors of cardiac events with a hazard ratio of 0.936 and 1.015 (95% confidence interval [CI]: 0.860-0.974, P = 0.006; and 95% CI: 1.003-1.027, p = 0.016), respectively. The measurement of TS and TWA is useful for assessing risk for re-hospitalization and cardiac death in HF patients. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Ability of a 5-minute electrocardiography (ECG) for predicting arrhythmias in Doberman Pinschers with cardiomyopathy in comparison with a 24-hour ambulatory ECG.

    Science.gov (United States)

    Wess, G; Schulze, A; Geraghty, N; Hartmann, K

    2010-01-01

    Ventricular premature contractions (VPCs) are common in the occult stage of cardiomyopathy in Doberman Pinschers. Although the gold standard for detecting arrhythmia is the 24-hour ambulatory electrocardiography (ECG) (Holter), this method is more expensive, time-consuming and often not as readily available as common ECG. Comparison of 5-minute ECGs with Holter examinations. Eight hundred and seventy-five 5-minute ECGs and Holter examinations of 431 Doberman Pinschers. Each examination included a 5-minute ECG and Holter examination. A cut-off value of > 100 VPCs/24 hours using Holter was considered diagnostic for the presence of cardiomyopathy. Statistical evaluation included calculation of sensitivity, specificity, positive predictive value, and negative predictive value. Holter examinations revealed > 100 VPCs/24 hours in 204/875 examinations. At least 1 VPC during a 5-minute ECG was detected in 131 (64.2%) of these 204 examinations. No VPCs were found in the 5-minute ECG in 73 (35.8%) examinations of affected Doberman Pinschers. A 5-minute ECG with at least 1 VPC as cut-off had a sensitivity of 64.2%, a specificity of 96.7%, a positive predictive value of 85.6% and a negative predictive value of 89.9% for the presence of > 100 VPCs/24 hours. A 5-minute ECG is a rather insensitive method for detecting arrhythmias in Doberman Pinschers. However, the occurrence of at least 1 VPC in 5 minutes strongly warrants further examination of the dog, because specificity (96.7%) and positive predictive value (85.6%) are high and could suggest occult cardiomyopathy.

  9. Long-term monitoring shows hepatitis B virus resistance to entecavir in nucleoside-naïve patients is rare through 5 years of therapy.

    Science.gov (United States)

    Tenney, Daniel J; Rose, Ronald E; Baldick, Carl J; Pokornowski, Kevin A; Eggers, Betsy J; Fang, Jie; Wichroski, Michael J; Xu, Dong; Yang, Joanna; Wilber, Richard B; Colonno, Richard J

    2009-05-01

    Patients with chronic hepatitis B virus (HBV) infection who develop antiviral resistance lose benefits of therapy and may be predisposed to further resistance. Entecavir (ETV) resistance (ETVr) results from HBV reverse transcriptase substitutions at positions T184, S202, or M250, which emerge in the presence of lamivudine (LVD) resistance substitutions M204I/V +/- L180M. Here, we summarize results from comprehensive resistance monitoring of patients with HBV who were continuously treated with ETV for up to 5 years. Monitoring included genotypic analysis of isolates from all patients at baseline and when HBV DNA was detectable by polymerase chain reaction (> or = 300 copies/mL) from Years 1 through 5. In addition, genotyping was performed on isolates from patients experiencing virologic breakthrough (> or = 1 log(10) rise in HBV DNA). In vitro phenotypic ETV susceptibility was determined for virologic breakthrough isolates, and for HBV containing novel substitutions emerging during treatment. The results over 5 years of therapy showed that in nucleoside-naïve patients, the cumulative probability of genotypic ETVr and genotypic ETVr associated with virologic breakthrough was 1.2% and 0.8%, respectively. In contrast, a reduced barrier to resistance was observed in LVD-refractory patients, as the LVD resistance substitutions, a partial requirement for ETVr, preexist, resulting in a 5-year cumulative probability of genotypic ETVr and genotypic ETVr associated with breakthrough of 51% and 43%, respectively. Importantly, only four patients who achieved < 300 copies/mL HBV DNA subsequently developed ETVr. Long-term monitoring showed low rates of resistance in nucleoside-naïve patients during 5 years of ETV therapy, corresponding with potent viral suppression and a high genetic barrier to resistance. These findings support ETV as a primary therapy that enables prolonged treatment with potent viral suppression and minimal resistance.

  10. Arrhythmogenic effects of hypoglycemia in children and adolescents with type 1 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Dmitriy Nikitich Laptev

    2013-12-01

    Full Text Available Aim. To determine the effects of hypoglycemia on the duration of QT interval, heart rate variability (HRV and frequency of arrhythmic events, as well as to closer investigate the factors associated with the development of various heart rhythm disorders in children and adolescents with type 1 diabetes mellitus (T1DM. Materials and methods.  The study included 150 children and adolescents with T1DM at the age of 6?18 years. All participants underwent Holter monitoring and continuous glucose monitoring (CGM for 24 hours. QTc and HRV parameters (SDNN, RMSSD, SVVR were calculated automatically. Data was averaged for 5?-interval and juxtaposed with CGM. Patients identified with hypoglycemic events (blood glucose

  11. Concurrent measurement of "real-world" stress and arousal in individuals with psychosis: assessing the feasibility and validity of a novel methodology.

    Science.gov (United States)

    Kimhy, David; Delespaul, Philippe; Ahn, Hongshik; Cai, Shengnan; Shikhman, Marina; Lieberman, Jeffrey A; Malaspina, Dolores; Sloan, Richard P

    2010-11-01

    Psychosis has been repeatedly suggested to be affected by increases in stress and arousal. However, there is a dearth of evidence supporting the temporal link between stress, arousal, and psychosis during "real-world" functioning. This paucity of evidence may stem from limitations of current research methodologies. Our aim is to the test the feasibility and validity of a novel methodology designed to measure concurrent stress and arousal in individuals with psychosis during "real-world" daily functioning. Twenty patients with psychosis completed a 36-hour ambulatory assessment of stress and arousal. We used experience sampling method with palm computers to assess stress (10 times per day, 10 AM → 10 PM) along with concurrent ambulatory measurement of cardiac autonomic regulation using a Holter monitor. The clocks of the palm computer and Holter monitor were synchronized, allowing the temporal linking of the stress and arousal data. We used power spectral analysis to determine the parasympathetic contributions to autonomic regulation and sympathovagal balance during 5 minutes before and after each experience sample. Patients completed 79% of the experience samples (75% with a valid concurrent arousal data). Momentary increases in stress had inverse correlation with concurrent parasympathetic activity (ρ = -.27, P feasibility and validity of our methodology in individuals with psychosis. The methodology offers a novel way to study in high time resolution the concurrent, "real-world" interactions between stress, arousal, and psychosis. The authors discuss the methodology's potential applications and future research directions.

  12. Depressed heart rate variability as an independent predictor of death in chronic congestive heart failure secondary to ischemic or idiopathic dilated cardiomyopathy.

    Science.gov (United States)

    Ponikowski, P; Anker, S D; Chua, T P; Szelemej, R; Piepoli, M; Adamopoulos, S; Webb-Peploe, K; Harrington, D; Banasiak, W; Wrabec, K; Coats, A J

    1997-06-15

    After acute myocardial infarction, depressed heart rate variability (HRV) has been proven to be a powerful independent predictor of a poor outcome. Although patients with chronic congestive heart failure (CHF) have also markedly impaired HRV, the prognostic value of HRV analysis in these patients remains unknown. The aim of this study was to investigate whether HRV parameters could predict survival in 102 consecutive patients with moderate to severe CHF (90 men, mean age 58 years, New York Heart Association [NYHA] class II to IV, CHF due to idiopathic dilated cardiomyopathy in 24 patients and ischemic heart disease in 78 patients, ejection fraction [EF], 26%; peak oxygen consumption, 16.9 ml/kg/min) after exclusion of patients in atrial fibrilation with diabetes or with chronic renal failure. In the prognostic analysis (Cox proportional-hazards model, Kaplan-Meier survival analysis), the following factors were investigated: age, CHF etiology, NYHA class, EF, peak oxygen consumption, presence of ventricular tachycardia on Holter monitoring, and HRV measures derived from 24-hour electrocardiography monitoring, calculated in the time (standard deviation of all normal RR intervals [SDNN], standard deviation of 5-minute RR intervals [SDANN], mean of all 5-minute standard deviations of RR intervals [SD], root-mean-square of difference of successive RR intervals [rMSSD], and percentage of adjacent RR intervals >50 ms different [pNN50]) and frequency domain (total power [TP], power within low-frequency band [LF], and power within high-frequency band [HF]). During follow-up of 584 +/- 405 days (365 days in all who survived), 19 patients (19%) died (mean time to death: 307 +/- 315 days, range 3 to 989). Cox's univariate analysis identified the following factors to be predictors of death: NYHA (p = 0.003), peak oxygen consumption (p = 0.01), EF (p = 0.02), ventricular tachycardia on Holter monitoring (p = 0.05), and among HRV measures: SDNN (p = 0.004), SDANN (p = 0.003), SD

  13. Attitudes toward Electronic Monitoring among Monitored Offenders and Criminal Justice Students.

    Science.gov (United States)

    Payne, Brian K.; Gainey, Randy R.

    1999-01-01

    Examines what 180 students think about electronic monitoring and compares their perceptions to those of 29 electronically-monitored offenders. Results show that students were less supportive of electronic monitoring but when asked about what offenders have to give up, they viewed the sanction more punitively than did offenders. Implications…

  14. VLSI in medicine

    CERN Document Server

    Einspruch, Norman G

    1989-01-01

    VLSI Electronics Microstructure Science, Volume 17: VLSI in Medicine deals with the more important applications of VLSI in medical devices and instruments.This volume is comprised of 11 chapters. It begins with an article about medical electronics. The following three chapters cover diagnostic imaging, focusing on such medical devices as magnetic resonance imaging, neurometric analyzer, and ultrasound. Chapters 5, 6, and 7 present the impact of VLSI in cardiology. The electrocardiograph, implantable cardiac pacemaker, and the use of VLSI in Holter monitoring are detailed in these chapters. The

  15. A Novel 12-Lead ECG T-Shirt with Active Electrodes

    Directory of Open Access Journals (Sweden)

    Anna Boehm

    2016-11-01

    Full Text Available We developed an ECG T-shirt with a portable recorder for unobtrusive and long-term multichannel ECG monitoring with active electrodes. A major drawback of conventional 12-lead ECGs is the use of adhesive gel electrodes, which are uncomfortable during long-term application and may even cause skin irritations and allergic reactions. Therefore, we integrated comfortable patches of conductive textile into the ECG T-shirt in order to replace the adhesive gel electrodes. In order to prevent signal deterioration, as reported for other textile ECG systems, we attached active circuits on the outside of the T-shirt to further improve the signal quality of the dry electrodes. Finally, we validated the ECG T-shirt against a commercial Holter ECG with healthy volunteers during phases of lying down, sitting, and walking. The 12-lead ECG was successfully recorded with a resulting mean relative error of the RR intervals of 0.96% and mean coverage of 96.6%. Furthermore, the ECG waves of the 12 leads were analyzed separately and showed high accordance. The P-wave had a correlation of 0.703 for walking subjects, while the T-wave demonstrated lower correlations for all three scenarios (lying: 0.817, sitting: 0.710, walking: 0.403. The other correlations for the P, Q, R, and S-waves were all higher than 0.9. This work demonstrates that our ECG T-shirt is suitable for 12-lead ECG recordings while providing a higher level of comfort compared with a commercial Holter ECG.

  16. Real-time continuous glucose monitoring shows high accuracy within 6 hours after sensor calibration: a prospective study.

    Directory of Open Access Journals (Sweden)

    Xiao-Yan Yue

    Full Text Available Accurate and timely glucose monitoring is essential in intensive care units. Real-time continuous glucose monitoring system (CGMS has been advocated for many years to improve glycemic management in critically ill patients. In order to determine the effect of calibration time on the accuracy of CGMS, real-time subcutaneous CGMS was used in 18 critically ill patients. CGMS sensor was calibrated with blood glucose measurements by blood gas/glucose analyzer every 12 hours. Venous blood was sampled every 2 to 4 hours, and glucose concentration was measured by standard central laboratory device (CLD and by blood gas/glucose analyzer. With CLD measurement as reference, relative absolute difference (mean±SD in CGMS and blood gas/glucose analyzer were 14.4%±12.2% and 6.5%±6.2%, respectively. The percentage of matched points in Clarke error grid zone A was 74.8% in CGMS, and 98.4% in blood gas/glucose analyzer. The relative absolute difference of CGMS obtained within 6 hours after sensor calibration (8.8%±7.2% was significantly less than that between 6 to 12 hours after calibration (20.1%±13.5%, p<0.0001. The percentage of matched points in Clarke error grid zone A was also significantly higher in data sets within 6 hours after calibration (92.4% versus 57.1%, p<0.0001. In conclusion, real-time subcutaneous CGMS is accurate in glucose monitoring in critically ill patients. CGMS sensor should be calibrated less than 6 hours, no matter what time interval recommended by manufacturer.

  17. The arrangement of deformation monitoring project and analysis of monitoring data of a hydropower engineering safety monitoring system

    Science.gov (United States)

    Wang, Wanshun; Chen, Zhuo; Li, Xiuwen

    2018-03-01

    The safety monitoring is very important in the operation and management of water resources and hydropower projects. It is the important means to understand the dam running status, to ensure the dam safety, to safeguard people’s life and property security, and to make full use of engineering benefits. This paper introduces the arrangement of engineering safety monitoring system based on the example of a water resource control project. The monitoring results of each monitoring project are analyzed intensively to show the operating status of the monitoring system and to provide useful reference for similar projects.

  18. Environmental Monitoring, Water Quality - MO 2009 Stream Team Volunteer Water Quality Monitoring Sites (SHP)

    Data.gov (United States)

    NSGIC State | GIS Inventory — This data set shows the monitoring locations of trained Volunteer Water Quality Monitors. A monitoring site is considered to be a 300 foot section of stream channel....

  19. Monitoring-induced disruption in skilled typewriting.

    Science.gov (United States)

    Snyder, Kristy M; Logan, Gordon D

    2013-10-01

    It is often disruptive to attend to the details of one's expert performance. The current work presents four experiments that utilized a monitor to report protocol to evaluate the sufficiency of three accounts of monitoring-induced disruption. The inhibition hypothesis states that disruption results from costs associated with preparing to withhold inappropriate responses. The dual-task hypothesis states that disruption results from maintaining monitored information in working memory. The implicit-explicit hypothesis states that disruption results from explicitly monitoring details of performance that are normally implicit. The findings suggest that all three hypotheses are sufficient to produce disruption, but inhibition and dual-task costs are not necessary. Experiment 1 showed that monitoring to report was disruptive even when there was no requirement to inhibit. Experiment 2 showed that maintaining information in working memory caused some disruption but much less than monitoring to report. Experiment 4 showed that monitoring to inhibit was more disruptive than monitoring to report, suggesting that monitoring is more disruptive when it is combined with other task requirements, such as inhibition. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  20. [The influence of physical exercise on heart rate variability].

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies

  1. Haptoglobin genotype and risk markers of cardiovascular disease in patients with chronic kidney disease

    DEFF Research Database (Denmark)

    Strandhave, Charlotte; Svensson, My; Krarup, Henrik

    2013-01-01

    -5 were included. Hp genotype was determined by high-performance liquid chromatography. HRV was analysed from the 24 h Holter recordings. Hs-CRP was measured using an immunoturbidimetric assay. The results show that the HRV indices SDNN and SDANN were significantly lower in the Hp 2-2 patients (P = 0...

  2. Neurocardiogenic Syncope and Supraventricular Tachycardia in Association with a Rare Congenital Aortic Valve Abnormality

    Directory of Open Access Journals (Sweden)

    Yashwant Agrawal

    2016-01-01

    Full Text Available We report a case of a 26-year-old woman who presented with multiple episodes of syncope over a five-months period of time. Transthoracic echocardiogram had shown a normal functioning quadricuspid aortic valve (QAV which was also confirmed on a transesophageal echocardiogram. Computed tomographic angiography of heart and coronary arteries showed the QAV with equal size of all aortic cusps and normal coronary arteries. Intermittent chest pain and palpitations warranted an exercise stress test. The stress test revealed normal aerobic exertion, with achievement of 101% of maximal peak heart rate. However, during peak stress, we noted a drop in her blood pressure significantly resulting in dizziness. No arrhythmias were noted during the stress test. With recurrent syncope episodes and palpitations, Holter monitoring was done, revealing supraventricular tachycardia (SVT. We discuss current available literature and coassociations with QAV. New association of QAV with SVT needs further analysis.

  3. Are Changes in Heart Rate Variability During Hypoglycemia Confounded by the Presence of Cardiovascular Autonomic Neuropathy in Patients with Diabetes?

    DEFF Research Database (Denmark)

    Cichosz, Simon Lebech; Frystyk, Jan; Tarnow, Lise

    2017-01-01

    BACKGROUND: We have recently shown how the combination of information from continuous glucose monitor (CGM) and heart rate variability (HRV) measurements can be used to construct an algorithm for prediction of hypoglycemia in both bedbound and active patients with type 1 diabetes (T1D). Questions...... with CGM and a Holter device while they performed normal daily activities. CAN was diagnosed using two cardiac reflex tests: (1) deep breathing and (2) orthostatic hypotension and end organ symptoms. Early CAN was defined as the presence of one abnormal reflex test and severe CAN was defined as two...

  4. Assesment of Rhythm Disorders in Classical and Nonclassical Mitral Valve Prolapse.

    Science.gov (United States)

    Hodzic, Enisa

    2018-02-01

    Mitral Valve Prolapse (MVP) is the most common cardiac valve pathology of to day. Aim of article was to identify the types and frequency of potentially malignant arrhythmia and atrial brillation in patients with MVP, to determine the differences in these arrhythmias between classical and non-classical MVP, to evaluate the correlation of potentially malignant arrhythmia and atrial fibrillation with MVP with possible clinical complications of arrhythmogenic sudden cardiac death and potential risk of thromboembolic vascular incident. Article has retrospective-prospective analytical character and present observational study on 239 patients (120 with MVP (66 with classical and 54 with non-classical MVP), who had a subjective feeling of palpitations and/or pain in the chest, and/or episode of syncope, and did not have ischemic heart disease or another valve pathology) and 119 healthy patients in the control group. All patients were analyzed by 24-hour ECG Holter. Signifficant difference in all analyzed arrhythmias between classical MVP and control group (p MVP (p = 0.016). The potential risk of cardiac death and vascular incidence is signi cantly higher in classical MVP than in non-classical MVP, implying the need for routine ECG-Holter monitoring in their diagnosis for timely prevention of clinical arrhythmogenic complications.

  5. Distributed computing environment monitoring and user expectations

    International Nuclear Information System (INIS)

    Cottrell, R.L.A.; Logg, C.A.

    1996-01-01

    This paper discusses the growing needs for distributed system monitoring and compares it to current practices. It then goes to identify the components of distributed system monitoring and shows how they are implemented and successfully used at one site today to address the Local area Network (WAN), and host monitoring. It shows how this monitoring can be used to develop realistic service level expectations and also identifies the costs. Finally, the paper briefly discusses the future challenges in network monitoring. (author)

  6. Movement monitoring device

    International Nuclear Information System (INIS)

    Ichikawa, Takashi; Yoneda, Yasuaki; Hanatsumi, Masaharu.

    1997-01-01

    The present invention provides a device suitable to accurate recognition for the moving state of reactor core fuels as an object to be monitored in a nuclear power plant. Namely, the device of the present invention prepares each of scheduled paths for the movement of the object to be monitored and executed moving paths along with the movement based on the information of the movement obtained from scheduled information for the movement of the reactor core fuels as a object to be monitored and the actual movement of the object to be monitored. The results of the preparation are outputted. As an output mode, (1) the results of preparation for each of the paths for movement and the results of the monitoring obtained by monitoring the state of the object to be monitored are jointed and outputted, (2) images showing each of the paths for the movement are formed, and the formed images are displayed on a screen, and (3) each of the moving paths is prepared as an image, and the image is displayed together with the image of the regions before and after the movement of the object to be monitored. In addition, obtained images of each of the paths for the movement and the monitored images obtained by monitoring the state of the object to be monitored are joined and displayed. (I.S.)

  7. Distributed computing environment monitoring and user expectations

    International Nuclear Information System (INIS)

    Cottrell, R.L.A.; Logg, C.A.

    1995-11-01

    This paper discusses the growing needs for distributed system monitoring and compares it to current practices. It then goes on to identify the components of distributed system monitoring and shows how they are implemented and successfully used at one site today to address the Local Area Network (LAN), network services and applications, the Wide Area Network (WAN), and host monitoring. It shows how this monitoring can be used to develop realistic service level expectations and also identifies the costs. Finally, the paper briefly discusses the future challenges in network monitoring

  8. Heart rate turbulence after ventricular premature beats in healthy Doberman pinschers and those with dilated cardiomyopathy.

    Science.gov (United States)

    Harris, J D; Little, C J L; Dennis, J M; Patteson, M W

    2017-10-01

    To describe the measurement of heart rate turbulence (HRT) after ventricular premature beats and compare HRT in healthy Doberman pinschers and those with dilated cardiomyopathy (DCM), with and without congestive heart failure (CHF). Sixty-five client-owned Dobermans: 20 healthy (NORMAL), 31 with preclinical DCM and 14 with DCM and CHF (DCM + CHF). A retrospective study of data retrieved from clinical records and ambulatory ECG (Holter) archives, including data collected previously for a large-scale prospective study of Dobermans with preclinical DCM. Holter data were reanalysed quantitatively, including conventional time-domain heart rate variability and the HRT parameters turbulence onset and turbulence slope. Heart rate turbulence could be measured in 58/65 dogs. Six Holter recordings had inadequate ventricular premature contractions (VPCs) and one exhibited VPCs too similar to sinus morphology. Heart rate turbulence parameter, turbulence onset, was significantly reduced in DCM dogs, whereas conventional heart rate variability measures were not. Heart rate variability and HRT markers were reduced in DCM + CHF dogs as expected. Heart rate turbulence can be measured from the majority of good quality standard canine 24-hour Holter recordings with >5 VPCs. Turbulence onset is significantly reduced in Dobermans with preclinical DCM which indicates vagal withdrawal early in the course of disease. Heart rate turbulence is a powerful prognostic indicator in human cardiac disease which can be measured from standard 24-hour ambulatory ECG (Holter) recordings using appropriate computer software. Further studies are warranted to assess whether HRT may be of prognostic value in dogs with preclinical DCM and in other canine cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Compact neutron flux monitor

    International Nuclear Information System (INIS)

    Madhavi, V.; Phatak, P.R.; Bahadur, C.; Bayala, A.K.; Jakati, R.K.; Sathian, V.

    2003-01-01

    Full text: A compact size neutron flux monitor has been developed incorporating standard boards developed for smart radiation monitors. The sensitivity of the monitors is 0.4cps/nV. It has been tested up to 2075 nV flux with standard neutron sources. It shows convincing results even in high flux areas like 6m away from the accelerator in RMC (Parel) for 106/107 nV. These monitors have a focal and remote display, alarm function with potential free contacts for centralized control and additional provision of connectivity via RS485/Ethernet. This paper describes the construction, working and results of the above flux monitor

  10. Monitor Sustainable Netherlands 2011; Monitor Duurzaam Nederland 2011

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-09-15

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk]. [Dutch] De Monitor geeft een beeld van de duurzaamheid van de Nederlandse samenleving. Het laat zien op welke terreinen het goed gaat en waar er vanuit een duurzaamheidsoptiek 'zorgen voor morgen' bestaan. Geanalyseerd wordt hoe ons land ervoor staat op het gebied van klimaatverandering, biodiversiteit, gezondheid, kennis, vergrijzing en sociale cohesie. Deze, en vele andere onderwerpen worden in deze monitor behandeld aan de hand van een set van duurzaamheidsindicatoren en detailanalyses.

  11. Monitor Sustainable Netherlands 2009; Monitor Duurzaam Nederland 2009

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-02-15

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk]. [Dutch] De Monitor geeft een beeld van de duurzaamheid van de Nederlandse samenleving. Hij laat zien op welke terreinen het goed gaat en waar er vanuit een duurzaamheidsoptiek 'zorgen voor morgen' bestaan. Geanalyseerd wordt hoe ons land ervoor staat op het gebied van klimaatverandering, biodiversiteit, gezondheid, kennis, vergrijzing en sociale cohesie. Deze, en vele andere onderwerpen worden in deze monitor behandeld aan de hand van een set van duurzaamheidsindicatoren en detailanalyses.

  12. Consumption of Caffeinated Products and Cardiac Ectopy.

    Science.gov (United States)

    Dixit, Shalini; Stein, Phyllis K; Dewland, Thomas A; Dukes, Jonathan W; Vittinghoff, Eric; Heckbert, Susan R; Marcus, Gregory M

    2016-01-26

    Premature cardiac contractions are associated with increased morbidity and mortality. Though experts associate premature atrial contractions (PACs) and premature ventricular contractions (PVCs) with caffeine, there are no data to support this relationship in the general population. As certain caffeinated products may have cardiovascular benefits, recommendations against them may be detrimental. We studied Cardiovascular Health Study participants with a baseline food frequency assessment, 24-hour ambulatory electrocardiography (Holter) monitoring, and without persistent atrial fibrillation. Frequencies of habitual coffee, tea, and chocolate consumption were assessed using a picture-sort food frequency survey. The main outcomes were PACs/h and PVCs/hour. Among 1388 participants (46% male, mean age 72 years), 840 (61%) consumed ≥1 caffeinated product per day. The median numbers of PACs and PVCs/h and interquartile ranges were 3 (1-12) and 1 (0-7), respectively. There were no differences in the number of PACs or PVCs/h across levels of coffee, tea, and chocolate consumption. After adjustment for potential confounders, more frequent consumption of these products was not associated with ectopy. In examining combined dietary intake of coffee, tea, and chocolate as a continuous measure, no relationships were observed after multivariable adjustment: 0.48% fewer PACs/h (95% CI -4.60 to 3.64) and 2.87% fewer PVCs/h (95% CI -8.18 to 2.43) per 1-serving/week increase in consumption. In the largest study to evaluate dietary patterns and quantify cardiac ectopy using 24-hour Holter monitoring, we found no relationship between chronic consumption of caffeinated products and ectopy. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  13. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken [Shakaihoken Chukyo Hospital, Nagoya (Japan)] [and others

    2000-05-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6{+-}14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3{+-}9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280{+-}0.0068 vs ASO group 0.0219{+-}0.0083), and gradually increased with time (1-3 years: 0.0470{+-}0.0157 vs 0.0314{+-}0.0124). (author)

  14. Evaluation of cardiac autonomic nerves by iodine-123 metaiodobenzylguanidine scintigraphy and ambulatory electrocardiography in patients after arterial switch operations

    International Nuclear Information System (INIS)

    Sakurai, Hajime; Maeda, Masanobu; Miyahara, Ken

    2000-01-01

    The autonomic cardiac nerves reach the heart after passing through the vicinity of the aortic root and the pulmonary trunk. The arterial switch operation (ASO) completely transects the ascending aorta and the pulmonary trunk. Therefore, this surgical procedure virtually denerves the heart. Cardiac sympathetic denervation and reinnervation were evaluated in patients after ASO using iodine-123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy and parasympathetic denervation and reinnervation using ambulatory electrocardiography [Holter electrocardiogram (ECG)]. MIBG scintigraphy was performed in 14 patients who underwent ASO (ASO group) and 3 patients who underwent other open heart surgery (control group). All patients in the ASO group underwent the operation in the neonatal or infantile period. Planar and single photon emission computed tomography (SPECT) images of the myocardium were obtained. Defect score was determined by the SPECT images as a semi-quantitative index. The mean interval between ASO and MIBG scintigraphy was 25.6±14.6 months. Holter ECG was also performed in 14 patients in the ASO group and 19 age-matched normal children. The Holter ECGs were plotted on a Lorenz plot. The H index, which is related to vagal tone for the cardiovascular system, was calculated from the R-R intervals. The mean interval between the ASO and Holter ECG was 8.3±9.7 months. MIBG scintigraphy in the control group demonstrated an almost normal homogeneous tracer uptake, but showed extremely reduced tracer uptake and significantly higher defect score in the ASO group. The extent and degree of the reduction of MIBG uptake improved with time after the ASO. The heart-to-mediastinum MIBG count ratio tended to increase with time. The H index of the ASO group was lower than that of normal children (<12 months: Control group 0.0280±0.0068 vs ASO group 0.0219±0.0083), and gradually increased with time (1-3 years: 0.0470±0.0157 vs 0.0314±0.0124). (author)

  15. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  16. Monitoring ARC services with GangliARC

    International Nuclear Information System (INIS)

    Cameron, D; Karpenko, D

    2012-01-01

    Monitoring of Grid services is essential to provide a smooth experience for users and provide fast and easy to understand diagnostics for administrators running the services. GangliARC makes use of the widely-used Ganglia monitoring tool to present web-based graphical metrics of the ARC computing element. These include statistics of running and finished jobs, data transfer metrics, as well as showing the availability of the computing element and hardware information such as free disk space left in the ARC cache. Ganglia presents metrics as graphs of the value of the metric over time and shows an easily-digestable summary of how the system is performing, and enables quick and easy diagnosis of common problems. This paper describes how GangliARC works and shows numerous examples of how the generated data can quickly be used by an administrator to investigate problems. It also presents possibilities of combining GangliARC with other commonly-used monitoring tools such as Nagios to easily integrate ARC monitoring into the regular monitoring infrastructure of any site or computing centre.

  17. Exercise-Induced Ventricular Fibrillation: Seven Years Follow-Up

    Directory of Open Access Journals (Sweden)

    Gökmen Gemici

    2011-11-01

    Full Text Available We present a 7-year follow-up of a 55-year-old male who experienced ventricular fibrillation during the recovery period of exercise testing and refused implantation of an ICD. Normal left ventricular systolic function was found on echocardiographic examination, and coronary angiography revealed only a side branch disease with a vessel diameter of less than 2 millimeters. The patient was discharged on metoprolol and ASA in addition to his previous treatment with lisinopril and simvastatin. Outpatient cardiac evaluation by repeated 24-hour ECG monitorizations (Holter revealed normal findings. On follow up visits every six months for the past seven years, the patient was found to be asymptomatic.

  18. BeMonitored: Monitoring psychophysiology and behavior using Android in phobias.

    Science.gov (United States)

    Brás, Susana; Soares, Sandra C; Moreira, Ricardo; Fernandes, José M

    2016-09-01

    It is of the utmost importance that researchers can recreate, as accurately as possible, real-life conditions in psychological studies. However, that is not always possible. Given that phobias are rather context-specific, their study is the ideal candidate to assess the feasibility of using a mobile and wearable device for obtaining physiological and behavioral data. In this article, we propose BeMonitored, a smartphone-based solution to support more ecologically valid monitoring of psychological experiments. BeMonitored delivers customizable, specific context-dependent audiovisual stimuli and uses external resources connected via Bluetooth or a smartphone's own resources, while capturing the participant's behavior, physiology, and environment. We used BeMonitored in a spider phobia case study and showed that spider phobics differed from control participants in face motion, captured by the smartphone camera. Moreover, our results also revealed heart rate differences between spider and neutral stimuli in phobic participants. The presented results emphasize the usefulness of smartphones for phobia monitoring. Considering their intrinsic characteristics, smartphones may constitute the natural evolution from the lab to more realistic contexts.

  19. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  20. β1-Adrenoceptor blocker aggravated ventricular arrhythmia.

    Science.gov (United States)

    Wang, Yan; Patel, Dimpi; Wang, Dao Wu; Yan, Jiang Tao; Hsia, Henry H; Liu, Hao; Zhao, Chun Xia; Zuo, Hou Juan; Wang, Dao Wen

    2013-11-01

    To assess the impact of β1 -adrenoceptor blockers (β1 -blocker) and isoprenaline on the incidence of idiopathic repetitive ventricular arrhythmia that apparently decreases with preprocedural anxiety. From January 2010 to July 2012, six patients were identified who had idiopathic ventricular arrhythmias that apparently decreased (by greater than 90%) with preprocedural anxiety. The number of ectopic ventricular beats per hour (VPH) was calculated from Holter or telemetry monitoring to assess the ectopic burden. The mean VPH of 24 hours from Holter before admission (VPH-m) was used as baseline (100%) for normalization. β1 -Blockers, isoprenaline, and/or aminophylline were administrated successively on the ward and catheter lab to evaluate their effects on the ventricular arrhythmias. Among 97 consecutive patients with idiopathic ventricular arrhythmias, six had reduction in normalized VPHs in the hour before the scheduled procedure time from (104.6 ± 4.6%) to (2.8 ± 1.6%) possibly due to preprocedural anxiety (P < 0.05), then increased to (97.9 ± 9.7%) during β1 -blocker administration (P < 0.05), then quickly reduced to (1.6 ± 1.0%) during subsequent isoprenaline infusion. Repeated β1 -blocker quickly counteracted the inhibitory effect of isoprenaline, and VPHs increased to (120.9 ± 2.4%) from (1.6 ± 1.0%; P < 0.05). Isoprenaline and β1 -blocker showed similar effects on the arrhythmias in catheter lab. In some patients with structurally normal heart and ventricular arrhythmias there is a marked reduction of arrhythmias associated with preprocedural anxiety. These patients exhibit a reproducible sequence of β1 -blocker aggravation and catecholamine inhibition of ventricular arrhythmias, including both repetitive ventricular premature beats and monomorphic ventricular tachycardia. ©2013, The Authors. Journal compilation ©2013 Wiley Periodicals, Inc.

  1. Gender differences of heart rate variability in healthy volunteers

    International Nuclear Information System (INIS)

    Saleem, S.; Majeed, S.M.I.; Khan, M.A.

    2012-01-01

    Objective: To identify the basic values of heart rate variability in Pakistani population and to verify our hypothesis that there are gender differences in cardiovascular autonomic modulation. Methods: The descriptive cross sectional study based on convenience probability sampling was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD) Pakistan. The duration of the study was from December 2009 to July 2010. It involved 24-hour holter monitoring of 45 healthy individuals using holter electrocardiography (ECG) recorder. Heart rate variability was analysed in time (SDNN, SDANN, SDNNi, rMSSD, pNN50) and frequency domains (power, VLF, LF, and HF). Results: The time domain indices; SDNN (male=140 +- 36 ms vs. females=122 +- 33 ms; p =0.09), SDANN (male=123 +- 34 ms vs. females=111+- 34 ms; P= 0.23), SDNNi (male=64 +-19 ms vs. females=52 +- 14 ms; P= 0.03), and pNN50 (male=14 +- 10 ms vs. females=12 +- 7 ms; P= 0.43) were decreased in female volunteers when compared with males. Comparison of frequency domain indices; Total power (male=4041 +- 3150 ms/sup 2/ vs. females=2750 +- 1439 ms/sup 2/; P= 0.07), VLF (male=291 2675 ms/sup 2/ vs. females=1843 +- 928 ms/sup 2/; P= 0.06), LF (male=788 +- 397 ms/sup 2/ vs. females=556 +- 346 ms/sup 2/; P= 0.04) and HF (male=318 +- 251 ms/sup 2/ vs. females=31 277 ms/sup 2/; P= 0.94) amongst males and females showed attenuated heart rate variability in females. Of all the observed values, SDNNi and LF were found significantly (p <0.05) decreased in women. Conclusion: In healthy population, heart rate variability is low in women than men. It reflects sympathetic dominance in women in our population. (author)

  2. Use of remote monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Fournel, E; Gouilloux, C

    1977-01-01

    Paper traces the development of remote monitoring devices, since their first appearance for safety purposes. Discusses their uses in coal mines: working and safety (definitions); sources and channels of information (transmission of information by automatic or verbal means); mine control stations; duties and responsibilities of persons in charge. Examines the contribution made by remote monitoring to management in production sector. Gives examples of assistance given to production management showing a very advantageous result on balance, by their use. The use of computers in real time and in batched mode is compared. Discusses their use in monitoring mine atmosphere. Very favorable results have already been obtained in France and abroad. The broadening scope and future of remote monitoring is considered.

  3. Monitoring Forsmark - Bird monitoring in Forsmark 2012

    Energy Technology Data Exchange (ETDEWEB)

    Green, Martin [Dept of Biology, Lund Univ., Lund (Sweden)

    2013-03-15

    This report summarizes the monitoring of selected listed (Swedish Red List and/or the EU Birds directive) breeding birds in Forsmark 2002 - 2012. Monitoring of eleven listed species was conducted in the regional model area, including the candidate area in 2012 in the same way as in earlier years. The results from 2012 generally follow patterns recorded in earlier years. 2012 was in general a better bird year compared to 2010 and 2011 and most species (82%) showed increasing or stable numbers from 2011 to 2012. Only two species (18%) decreased in numbers between the last two years. All in all, six species (55 %, black-throated diver, honey buzzard, black grouse, ural owl, wryneck and red-backed shrike) show no significant trends since the start of the bird monitoring (2002/2003/2004 depending on species). During this period three species (27 %, white-tailed eagle, osprey and lesser spotted woodpecker) have increased in numbers while just two (18 %, capercaillie and hazelhen) have decreased. A new pair of black-throated divers was discovered in 2012 and seven resident pairs were registered. Breeding success was very good, the second best during the study period. Population development follows the national pattern, but breeding success seems to be better in Forsmark than in the country as a whole. Honey buzzards and ospreys occurred in good numbers, and breeding success for ospreys was good. No signs of successful breedings of honey buzzards were recorded, but this may mean little as no detailed monitoring of breeding success is made for this species. The white-tailed eagles had their best breeding year since the start of the SKB bird monitoring, meaning that during the last two years local breeding success has been back at the level recorded before the site investigations started. The three grouse species (black grouse, capercaillie and hazelhen) again showed somewhat varying patterns between the last two years as well as in the long run. The black grouse increased

  4. Monitoring Forsmark-Bird monitoring in Forsmark 2012

    International Nuclear Information System (INIS)

    Green, Martin

    2013-03-01

    This report summarizes the monitoring of selected listed (Swedish Red List and/or the EU Birds directive) breeding birds in Forsmark 2002 - 2012. Monitoring of eleven listed species was conducted in the regional model area, including the candidate area in 2012 in the same way as in earlier years. The results from 2012 generally follow patterns recorded in earlier years. 2012 was in general a better bird year compared to 2010 and 2011 and most species (82%) showed increasing or stable numbers from 2011 to 2012. Only two species (18%) decreased in numbers between the last two years. All in all, six species (55 %, black-throated diver, honey buzzard, black grouse, ural owl, wryneck and red-backed shrike) show no significant trends since the start of the bird monitoring (2002/2003/2004 depending on species). During this period three species (27 %, white-tailed eagle, osprey and lesser spotted woodpecker) have increased in numbers while just two (18 %, capercaillie and hazelhen) have decreased. A new pair of black-throated divers was discovered in 2012 and seven resident pairs were registered. Breeding success was very good, the second best during the study period. Population development follows the national pattern, but breeding success seems to be better in Forsmark than in the country as a whole. Honey buzzards and ospreys occurred in good numbers, and breeding success for ospreys was good. No signs of successful breedings of honey buzzards were recorded, but this may mean little as no detailed monitoring of breeding success is made for this species. The white-tailed eagles had their best breeding year since the start of the SKB bird monitoring, meaning that during the last two years local breeding success has been back at the level recorded before the site investigations started. The three grouse species (black grouse, capercaillie and hazelhen) again showed somewhat varying patterns between the last two years as well as in the long run. The black grouse increased

  5. Enhanced safeguards via solution monitoring

    International Nuclear Information System (INIS)

    Burr, T.; Wangen, L.

    1996-09-01

    Solution monitoring is defined as the essentially continuous monitoring of solution level, density, and temperature in all tanks in the process that contain, or could contain, safeguards-significant quantities of nuclear material. This report describes some of the enhancements that solution monitoring could make to international safeguards. The focus is on the quantifiable benefits of solution monitoring, but qualitatively, solution monitoring can be viewed as a form of surveillance. Quantitatively, solution monitoring can in some cases improve diversion detection probability. For example, the authors show that under certain assumptions, solution monitoring can be used to reduce the standard deviation of the annual material balance, σ MB , from approximately 17 kg to approximately 4 kg. Such reduction in σ MB will not always be possible, as they discuss. However, in all cases, solution monitoring would provide assurance that the measurement error models are adequate so that one has confidence in his estimate of σ MB . Some of the results in this report were generated using data that were simulated with prototype solution monitoring software that they are developing. An accompanying document describes that software

  6. GAMMAGRAFÍA DE PERFUSIÓN MIOCÁRDICA EN MUJERES POSMENOPÁUSICAS CON ANGINA Y CORONARIAS EPICÁRDICAS ANGIOGRÁFICAMENTE NORMALES / Myocardial perfusion scintigraphy in postmenopausal women with angina and angiographically normal epicardial coronary

    Directory of Open Access Journals (Sweden)

    Sherien Sixto Fernández

    2011-03-01

    Full Text Available Introduction and Objectives: Microvascular angina is common in postmenopausal women. Myocardial ischemia was induced by stress testing, and reports have been published about the relationship between endothelial dysfunction and myocardial perfusion. The objective of this research was to determine whether myocardial ischemia can be evidenced by abnormalities in perfusion and function, as detected by myocardial scintigraphy in women with typical angina, normal coronary angiography and endothelial dysfunction. Methods: 59 women underwent lipid and endothelial function measurements by brachial artery ultrasound, in addition, a 24-hour ECG study (Holter. During the scintigraphy a stress-rest protocol was applied. Patients were divided into two groups according to presence (group I or absence (group II of myocardial perfusion defects. Results: 21 patients showed perfusion defects. 57 % of group I exhibited greater endothelial dysfunction. Only twelve patients showed reversible perfusion defects, and 75 % of the cases was associated with a reduction of post-stress left ventricular ejection fraction, greater than 5 %, and regional abnormalities of wall motion. Three patients in group I showed evidence of ischemia compared with four in Group II. Conclusions: The stress-induced ischemia was associated with a reduced post-stress ejection fraction and endothelial dysfunction in the studied women, and no ischemic changes in the Holter were found.

  7. Does the STAF score help detect paroxysmal atrial fibrillation in acute stroke patients?

    Science.gov (United States)

    Horstmann, S; Rizos, T; Güntner, J; Hug, A; Jenetzky, E; Krumsdorf, U; Veltkamp, R

    2013-01-01

    Detecting paroxysmal atrial fibrillation (pAF) soon after acute cerebral ischaemia has a major impact on secondary stroke prevention. Recently, the STAF score, a composite of clinical and instrumental findings, was introduced to identify stroke patients at risk of pAF. We aimed to validate this score in an independent study population. Consecutive patients admitted to our stroke unit with acute ischaemic stroke were prospectively enrolled. The diagnostic work-up included neuroimaging, neuroultrasound, baseline 12-channel electrocardiogram (ECG), 24-h Holter ECG, continuous ECG monitoring, and echocardiography. Presence of AF was documented according to the medical history of each patient and after review of 12-lead ECG, 24-h Holter ECG, or continuous ECG monitoring performed during the stay on the ward. Additionally, a telephone follow-up visit was conducted for each patient after 3 months to inquire about newly diagnosed AF. Items for each patient-age, baseline NIHSS, left atrial dilatation, and stroke etiology according to the TOAST criteria - were assessed to calculate the STAF score. Overall, 584 patients were enrolled in our analysis. AF was documented in 183 (31.3%) patients. In multivariable analysis, age, NIHSS, left atrial dilatation, and absence of vascular etiology were independent predictors for AF. The logistic AF-prediction model of the STAF score revealed fair classification accuracy in receiver operating characteristic curve analysis with an area under the curve of 0.84. STAF scores of ≥5 had a sensitivity of 79% and a specificity of 74% for predicting AF. The value of the STAF score for predicting the risk of pAF in stroke patients is limited. © 2012 The Author(s) European Journal of Neurology © 2012 EFNS.

  8. Relationship between the mismatch of 123I-BMIPP and 201Tl myocardial single-photon emission computed tomography and autonomic nervous system activity in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Yamanaka, Hiroyuki; Suzuki, Takeshi; Kishida, Hiroshi; Nagasawa, Koichi; Takano, Teruo

    2006-01-01

    The purpose of this study was to elucidate the relationship between the mismatch of thallium-201 (Tl) and iodine-123-beta-methyl-iodophenyl-pentadecanoic acid (BMIPP) myocardial single-photon emission computed tomography (SPECT) and autonomic nervous system activity in myocardial infarction (MI) patients. The subjects were 40 patients (34 males, 6 females) who underwent examinations by 123 I-BMIPP and 201 Tl myocardial SPECT imaging and 24-hour Holter monitoring within a 3-day period 3 weeks after the onset of their first MI. R-R intervals were analyzed every hour over a period of 24 hours by fast Fourier transformation (FFT). High frequency (HF) and low frequency (LF) were defined as markers of cardiac vagal activity in the former and the LF/HF ratio as sympathetic activity. Greater or more extensive decreases in the BMIPP image than that in the Tl image were defined as a positive mismatch. Patients were divided into positive and negative mismatch groups of 20 patients each. There were no significant differences between the 2 groups in age, sex, site of infarction, max CK (creatine kinase), max CK-MB, or left ventricular ejection fraction. The incidences of clinical signs suggesting residual myocardial ischemia were significantly greater in the positive than in the negative mismatch group (P 123 I-BMIPP and 201 Tl myocardial SPECT 3 weeks after a first acute myocardial infarction with uncomplicated moderate or severe heart failure and decreased heart rate variability are related to residual myocardial ischemia. A combined assessment of heart rate variability in 24 hour Holter electrocardiogram (ECG) monitoring and perfusion-metabolism mismatch in 123 I-BMIPP and 201 Tl myocardial SPECT is useful for determining residual myocardial ischemia in the follow-up of those with acute myocardial infarction. (author)

  9. A double-blind, placebo-controlled, randomised, parallel-group, dose-escalating, repeat dose study in healthy volunteers to evaluate the safety, tolerability, pharmacodynamic effects and pharmacokinetics of the once daily rectal application of NRL001 suppositories for 14 days.

    Science.gov (United States)

    Bell, D; Duffin, A; Jacobs, A; Pediconi, C; Gruss, H J

    2014-03-01

    The 1R,2S stereoisomer of methoxamine hydrochloride, NRL001, is a highly selective α1-adrenoceptor agonist being developed for the local treatment of non-structural faecal incontinence caused by weak internal anal sphincter tone. This study investigated the steady state pharmacokinetics (PK) and safety of 2 g rectal suppositories containing NRL001 in different strengths (7.5, 10, 12.5 or 15 mg). Healthy volunteers aged 18-45 years received 14 daily doses of NRL001 2 g suppositories or matching placebo. In each dose group nine participants received NRL001 and three received placebo. Blood samples to determine NRL001 concentrations were taken on Days 1, 7 and 14. Cardiovascular parameters were collected via electrocardiograms, Holter monitoring (three lead Holter monitor) and vital signs. Forty-eight volunteers were enrolled; 43 completed the study and were included in the PK analysis population. AUC and Cmax broadly increased with increasing dose, Tmax generally occurred between 4.0 and 5.0 h. Although the data did not appear strongly dose proportional, dose proportionality analysis did not provide evidence against dose proportionality as the log(dose) coefficients were not significantly < 1. NRL001 did not accumulate over time for any dose. Increasing NRL001 concentrations were related to changes in vital sign variables, most notably decreased heart rate. The most commonly reported adverse events (AEs) in the active treatment groups were paraesthesia and piloerection. Treatment with NRL001 was generally well tolerated over 14 days once daily dosing and plasma NRL001 did not accumulate over time. Treatment was associated with changes in vital sign variables, most notably decreased heart rate. AEs commonly reported with NRL001 treatment were events indicative of a systemic α-adrenergic effect. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  10. Avaliação clínica e funcional tardia de arritmias em crianças operadas de Tetralogia de Fallot Evaluación clínica y funcional tardía de arritmias en niños operados de tetralogía de Fallot Late clinical and functional assessment of arrhythmias in children after repair of Tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Maria Eulália Thebit Pfeiffer

    2010-09-01

    undergoing repair of TF, and to associate them with clinical aspects and laboratory tests. METHODS: Cross-sectional study of 37 patients undergoing repair of TF at Instituto Estadual de Cardiologia Aloysio de Castro (Rio de Janeiro. After review of the medical records and clinical assessment, the patients underwent electrocardiography (ECG, echocardiography (Echo, 24-h Holter monitoring and exercise test (ET, whose results were subjected to statistical analysis. RESULTS: A total of 37 patients of whom 54% were males with a mean age of 9.7 ± 3.5 years and mean follow-up period of 4.7 ± 1.9 years were studied. The abnormalities most frequently found were: on ECG: right bundle branch block (89%; Echo: severe pulmonary regurgitation (43%, mild pulmonary stenosis (73%, moderate right ventricular hypertrophy (RVH, 57%; on ET: low exercise capacity (90%, impaired chronotropic response (40%, arrhythmias (20%; on Holter monitoring: arrhythmias (59%, of which 44% were ventricular, 38% supraventricular, and 24% both ventricular and supraventricular, with predominance of infrequent and benign ventricular premature beats. Five patients (15% presented with multiform ventricular premature beats. There was an association of ventricular arrhythmia with moderate and severe RVH (p=0.026, as well as with right ventricle-to-pulmonary artery gradient (RV/PA > 45 mmHg (p=0.004. The logistic regression analysis showed that increased RV/PA gradient was an independent predictor of ventricular arrhythmia (p=0.017. CONCLUSION: Cardiac arrhythmia was a common finding in a large proportion of children and adolescents after surgical repair of TF; however, it was infrequent and benign in most of the cases. The RV/PA gradient was considered a strong predictor of ventricular arrhythmia.

  11. Quality control of thermoluminesce personal dose monitoring

    International Nuclear Information System (INIS)

    Shang Aiguo; He Wenchang; Zhao Fengtao

    2006-01-01

    In order to evaluate the influence factor to thermoluminesce personal dose monitoring result, the every question that can appear based on the fact was analyzed. The results show that the detector, annealing, measuring process can influence the monitoring result. It gives some measures to enhance monitoring quality. (authors)

  12. Monitor Infrastructure and Space 2012. Baseline; Monitor Infrastructuur en Ruimte 2012. Nulmeting

    Energy Technology Data Exchange (ETDEWEB)

    Kuiper, R.; Van der Schuit, J. [Planbureau voor de Leefomgeving PBL, Den Haag (Netherlands)

    2012-09-15

    What about the competitiveness of the Netherlands? Does the accessibility improve? Is the environment safe and sound? This Monitor shows the extent to which the goals of the Vision on Infrastructure and Spatial Planning (SVIR) are reached. The monitor contains indicators for thirteen national interests from the SVIR, the essential components of the Mobility Memorandum (2004) as included in the SVIR, and for some of the 'released' goals of the National Spatial Strategy (2006). This monitor contains the first measurement (baseline) of the indicators. The first follow-up survey is planned in 2014 [Dutch] Hoe staat het met de concurrentiekracht van Nederland? Verbetert de bereikbaarheid? Is de omgeving leefbaar en veilig? De Monitor Infrastructuur en Ruimte laat zien in hoeverre deze doelen uit de Structuurvisie Infrastructuur en Ruimte (SVIR) worden bereikt. De monitor bevat indicatoren voor de dertien nationale belangen uit de SVIR, de essentiele onderdelen van de Nota Mobiliteit (2004) zoals opgenomen in de SVIR, en voor enkele van de 'losgelaten' doelen uit de Nota Ruimte (2006). Deze monitor bevat de eerste meting (nulmeting) van de indicatoren. De eerste vervolgmeting is gepland in 2014.

  13. Radiation area monitoring by wireless-communicating area monitor with surveillance camera

    International Nuclear Information System (INIS)

    Shimura, Mitsuo; Kobayashi, Hiromitsu; Kitahara, Hideki; Kobayashi, Hironobu; Okamoto, Shinji

    2004-01-01

    Aiming at a dose reduction and a work efficiency improvement for nuclear power plants that have high dose regions, we have developed our system of wireless-communicating Area Monitor with Surveillance Camera, and have performed an on-site test. Now we are implementing this Area Monitor with Surveillance Camera for a use as a TV camera in the controlled-area, which enables a personal computer to simultaneously display two or more dose values and site live images on the screen. For the radiation detector of this Area Monitor System, our wireless-communicating dosimeter is utilized. Image data are transmitted via a wireless Local Area Network (LAN). As a test result, image transmission of a maximum of 20 frames per second has been realized, which shows that this concept is a practical application. Remote-site monitoring also has been realized from an office desk located within the non-controlled area, adopting a Japan's wireless phone system, PHS (Personal Handy Phone) for the transmission interface. (author)

  14. A risk-based approach to liquid effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements.

  15. A risk-based approach to liquid effluent monitoring

    International Nuclear Information System (INIS)

    Hull, L.C.

    1995-10-01

    DOE Order 5400.1 identifies six objectives of a liquid effluent monitoring program. A strategy is proposed that meets these objective in one of two ways: (1) by showing that effluent concentrations are below concentration limits set by permits or are below concentrations that could cause environmental problems or (2) by showing that concentrations in effluent have not changed from a period when treatment processes were in control and there were no unplanned releases. The intensity of liquid effluent monitoring should be graded to the importance of the source being monitored. This can be accomplished by determining the risk posed by the source. A definition of risk is presented that defines risk in terms of the statistical probability of exceeding a release limit and the time available to recover from an exceedance of a release limit. Three examples are presented that show this approach to grading an effluent monitoring program can be implemented at the Idaho National Engineering Laboratory and will reduce monitoring requirements

  16. Perspectives on wellness self-monitoring tools for older adults.

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J; Demiris, George

    2013-11-01

    Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults' personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians' tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Older adult participants' found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes toward wellness monitoring tools for older adults and brainstormed about various stakeholders' use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Our paper provides implications and solutions for how older adults' wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Perspectives on Wellness Self-Monitoring Tools for Older Adults

    Science.gov (United States)

    Huh, Jina; Le, Thai; Reeder, Blaine; Thompson, Hilaire J.; Demiris, George

    2013-01-01

    Purpose Our purpose was to understand different stakeholder perceptions about the use of self-monitoring tools, specifically in the area of older adults’ personal wellness. In conjunction with the advent of personal health records, tracking personal health using self-monitoring technologies shows promising patient support opportunities. While clinicians’ tools for monitoring of older adults have been explored, we know little about how older adults may self-monitor their wellness and health and how their health care providers would perceive such use. Methods We conducted three focus groups with health care providers (n=10) and four focus groups with community-dwelling older adults (n=31). Results Older adult participants’ found the concept of self-monitoring unfamiliar and this influenced a narrowed interest in the use of wellness self-monitoring tools. On the other hand, health care provider participants showed open attitudes towards wellness monitoring tools for older adults and brainstormed about various stakeholders’ use cases. The two participant groups showed diverging perceptions in terms of: perceived uses, stakeholder interests, information ownership and control, and sharing of wellness monitoring tools. Conclusions Our paper provides implications and solutions for how older adults’ wellness self-monitoring tools can enhance patient-health care provider interaction, patient education, and improvement in overall wellness. PMID:24041452

  18. Delegation of Monitoring in a Principal-Agent Relationship

    NARCIS (Netherlands)

    Strausz, R.G.

    1995-01-01

    This paper studies a principal-agent relationship with moral hazard in which the principal or the supervisor can monitor the agent's hidden action by using identical monitoring technologies. The paper shows that delegation of monitoring to the supervisor is profitable because of two effects. With

  19. Patient monitoring using infrastructure-oriented wireless LANs.

    Science.gov (United States)

    Varshney, Upkar

    2006-01-01

    There is considerable interest in using wireless and mobile technologies in patient monitoring in diverse environments including hospitals and nursing homes. However, there has not been much work in determining the requirements of patient monitoring and satisfying these requirements using infrastructure-oriented wireless networks. In this paper, we derive several requirements of patient monitoring and show how infrastructure-oriented wireless LANs, such as versions of IEEE 802.11, can be used to support patient monitoring in diverse environments.

  20. Monitoring auroral electrojets with satellite data

    DEFF Research Database (Denmark)

    Vennerstrøm, Susanne; Moretto, T.

    2013-01-01

    satellites. The method is simple enough to be implemented for real-time monitoring, especially since it does not require the full vector field measurement. We demonstrate the method on 5 years of Challenging Minisatellite Payload (CHAMP) data and show how the monitoring depends on the local time...

  1. Monitor Sustainable Netherlands 2011

    International Nuclear Information System (INIS)

    2011-09-01

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk]. [nl

  2. Monitor Sustainable Netherlands 2009

    International Nuclear Information System (INIS)

    2009-02-01

    The Monitor provides an image of the sustainability of the Dutch society. It shows which areas are successful and what the 'concerns for tomorrow' are from the point of view of sustainability. An analysis is conducted of how the Netherlands are doing in the fields of climate change, biodiversity, health, knowledge, graying and social cohesion. These and many other topics are discussed in this monitor by means of a number of sustainability indicators and detail analyses [mk] [nl

  3. Environmental monitoring for krypton-85

    International Nuclear Information System (INIS)

    Barber, D.E.

    1973-01-01

    85 Kr presents unique environmental monitoring problems because it does not react with other elements and compounds at normal ambient temperatures and pressures. However, elaborate means are available to manage the 85 Kr problem, but a simpler, inexpensive approach is required if monitoring is to be accomplished at many sampling locations. This work shows that environmental monitoring for 85 Kr is possible by collecting air samples in thin plastic bags, and counting the bags for beta particle activity. The direct counting of contained samples of this type makes it possible to detect concentrations less than the public MPC for 85 Kr. The bagged-sample technique is readily adaptable to any environmental monitoring station with power to run a low-volume air pump. The idea of counting the bagged-sample directly is a new, low-cost, approach to environmental gas monitoring which may have application in environmental, clinical, and industrial situations

  4. Clinical usefulness of 123I-MIBG myocardial spect in patients with cardiac sarcoidosis

    International Nuclear Information System (INIS)

    Kobayashi, Keiko; Hatsumi, Chie; Fujioka, Haruto

    1996-01-01

    This study was undertaken to assess whether 123 I-MIBG scintigraphy is useful to detect cardiac involvements of sarcoidosis. In 45 patients with sarcoidosis, dual SPECT with 123 I-MIBG and 201 Tl-Cl(Tl) were performed, and the findings were compared with electrocardiogram (ECG), 24 hour Holter ECG and ultrasound echocardiography. In order to evaluate cardiac involvements, Tl and MIBG extent score (E.S.) and severity score (S.S.) were calculated by a Bull's eye map in addition to visual evaluation. Abnormal findings were recognized in 8.9% of all subjects in echocardiography, in 22.2% of those in ECG and Holter ECG, in 40% of those in Tl scintigraphy, and in 64.4% of those in MIBG scintigraphy. All of the Tl and MIBG abnormalities were detected in left ventricles, especially at the basal septal wall. At the inferior wall, abnormalities were observed more frequently by MIBG than by Tl. Tl E.S., Tl S.S. and MIBG E.S. were significantly higher in 10 patients with abnormal ECG findings than in 35 patients with normal ECG findings. Also, all of 10 patients with abnormal ECG findings had abnormal MIBG image, but 3 of them showed normal Tl images. 11 of 35 patients with normal ECG findings showed abnormal Tl and MIBG images (group A), 8 of 35 patients showed normal Tl images and abnormal MIBG images (group B), and 16 of 35 patients showed normal Tl and MIBG images (group C). MIBG S.S. of group A (11.3±7.8) was significantly higher than that of group B (5.3±3.1) or group C (2.6±3.2). Furthermore, in group A, MIBG S.S. was significantly higher than Tl S.S. (5.5±2.8). In a case of normal ECG with abnormal MIBG images, we seriously suspect cardiac involvements and recommend repeated Holter ECG tests as necessary in order to detect critical arrythmia. MIBG scintigraphy appeared to be a sensitive and useful method for the early detection of cardiac sarcoidosis. (J.P.N.)

  5. Modeling Wireless Sensor Networks for Monitoring in Biological Processes

    DEFF Research Database (Denmark)

    Nadimi, Esmaeil

    parameters, as the use of wired sensors is impractical. In this thesis, a ZigBee based wireless sensor network was employed and only a part of the herd was monitored, as monitoring each individual animal in a large herd under practical conditions is inefficient. Investigations to show that the monitored...... (MMAE) approach to the data resulted in the highest classification success rate, due to the use of precise forth-order mathematical models which relate the feed offer to the pitch angle of the neck. This thesis shows that wireless sensor networks can be successfully employed to monitor the behavior...

  6. Environmental monitoring report, 1976

    International Nuclear Information System (INIS)

    1977-01-01

    The effluent and environmental monitoring programs maintained by the Pinellas Plant are designed to determine the efficiencies of treatment and control mechanisms; to provide measurements of discharge concentrations for comparison with applicable standards; and to assess the concentrations of these discharges in the environment. Site perimeter and off-site air samples for tritium gas and tritium oxide, as well as off-site surface water samples obtained to distances of 9.6 kilometers (6 miles) from the plant site and analyzed for tritium content, showed levels significantly less than 1 / 10 of 1 percent of the recommended guide for continuous nonoccupational exposure. Small sealed plutonium sources are utilized at this site. No plutonium was released to the environment and monitoring data showed environmental background levels

  7. Diurnal changes of blood pressure values (24 h blood pressures in women with polycystic ovary syndrome

    Directory of Open Access Journals (Sweden)

    Barbara Grzechocińska

    2011-06-01

    Full Text Available Background: More attention is being paid lately to polycystic ovary syndrome (PCOS not only in the aspect of fertility but also according to long-term metabolic and cardiovascular abnormalities. Observations of women with PCOS show that the occurrence of blood hypertension is more frequent after the menopause. There are few articles concerning the predictable symptoms of blood hypertension. It seems that twenty-four hour blood pressure monitoring and assessment of changes of diurnal rhythm could be useful in this group of patients.Aim of the study: The purpose of this study was to assess diurnal changes of blood pressure in women with polycystic ovary syndrome.Material and methods: 26 women with PCOS diagnosed according to Rotterdam consensus criteria and Androgen Excess Society (AES criteria were included in our study. The mean age of the examined women was 29.5 years and the mean BMI (body mass index was 24.7 kg/m2. The control group consisted of 12 age-matched women, without PCOS. Twenty-four hour Holter monitoring of ambulatory blood pressure was performed during normal daily activity in all patients. Halberg’s cosinor method was used to analyse daily biorhythm.Results: Results show the diurnal changes of systolic blood pressure in the preclinical phase in 30% and diastolic in 15% of PCOS women. In this group no physiological decrease of blood pressure at night time was observed.

  8. A case of delayed cardiac perforation of active ventricular lead

    Directory of Open Access Journals (Sweden)

    Hangyuan Guo

    2011-12-01

    Full Text Available A 65-year-old man was admitted as for one month of repetitive dizziness and one episode of syncope. Electrocardiogram showed sinus bradycardia and his Holter monitoring also showed sinus bradycardia with sinus arrest, sino-atrial block and a longest pause of 4.3 s. Then sick sinus syndrome and Adam-Stokes syndrome were diagnosed. Then a dual chamber pacemaker (Medtronic SDR303 was implanted and the parameters were normal by detection. The patient was discharged 1 week later with suture removed. Then 1.5 month late the patient was presented to hospital once again for sudden onset of chest pain with exacerbation after taking deep breath. Pacemaker programming showed both pacing and sensing abnormality with threshold of?5.0V and resistance of 1200?. Lead perforation was revealed by chest X-ray and confirmed by echocardiogram. Considering the fact that there was high risk to remove ventricular lead, spiral tip of previous ventricular lead was withdrew followed by implantation of a new ventricular active lead to the septum. Previous ventricular lead was maintained. As we know that the complications of lead perforation in the clinic was rare. Here we discuss the clinical management and the possible reasons for cardiac perforation of active ventricular lead.

  9. Developments in radioactive scrap monitoring

    International Nuclear Information System (INIS)

    Bellian, J.G.

    1997-01-01

    Over the past ten years there have been major developments in radiation monitoring systems used for detecting shielded radioactive sources in scrap metal. The extent of the problem and industry's awareness of the problem have both grown significantly during that time. The multimillion dollar expenses associated with decontamination after a source passes into the melt and the potential health hazard to employees and the public have added further impetus to the development of monitoring systems. Early attempts at scrap monitoring could detect some radiation, but testing with real life situations showed them to be virtually incapable of detecting shielded sources of radioactivity in incoming vehicles. More sophisticated detector technology and the development of advanced software made useful by more powerful microprocessors led to successive generations of monitoring systems with order-of-magnitude improvement in detection capability. The next generation includes larger detectors and more complex algorithms offering further improvement in truck and rail car monitoring. Complete solutions require monitoring at additional locations within the site, such as the charge bucket and conveyor lines, and at the scrap processor's site

  10. Advanced monitoring with complex stream processing

    CERN Multimedia

    CERN. Geneva

    2015-01-01

    Making sense of metrics and logs for service monitoring can be a complicated task. Valuable information is normally scattered across several streams of monitoring data, requiring aggregation, correlation and time-based analysis to promptly detect problems and failures. This presentations shows a solution which is used to support the advanced monitoring of the messaging services provided by the IT Department. It uses Esper, an open-source software product for Complex Event Processing (CEP), that analyses series of events for deriving conclusions from them.

  11. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals

    Directory of Open Access Journals (Sweden)

    Isabel G. Trindade

    2016-09-01

    Full Text Available This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  12. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals.

    Science.gov (United States)

    Trindade, Isabel G; Machado da Silva, José; Miguel, Rui; Pereira, Madalena; Lucas, José; Oliveira, Luís; Valentim, Bruno; Barreto, Jorge; Santos Silva, Manuel

    2016-09-24

    This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  13. EFFECT OF ANTIHYPERTENSIVE THERAPY BASED ON NEW METHOD OF INDIVIDUAL CHOICE OF DRUGS ON LEFT VENTRICULAR HYPERTROPHY IN ELDERLY PATIENTS

    Directory of Open Access Journals (Sweden)

    K. I. Pshenichkin

    2015-12-01

    Full Text Available Aim. To study the effects of antihypertensive therapy based on consideration of individual heart rhythm variability (HRV on left ventricular hypertrophy (LVH in hypertensive elderly patients.Material and methods. 60 hypertensive elderly patients with LVH were included in the study. They were split in two groups (30 people in each one. Patients of the group-I had common antihypertensive therapy. Patients of group-II received medications prescribed with consideration of individual heart rate variability. Holter monitoring with analysis of HRV, 24-hour blood pressure monitoring and ultrasonography were conducted initially and 18 months after treatment beginning.Results. BP control was reached in the majority of patients of both groups. The patients of group-II in comparison with patients of group-I had reduction of low- high frequency power ratio (LF/HF and higher rate of LVH reduction. Relationship between LVH dynamics and ratio LF/HF was found.Conclusion. Arterial hypertension therapy considering individual HRV contributes in LVH reduction in elderly patients.

  14. Monitoring and interpreting bioremediation effectiveness

    International Nuclear Information System (INIS)

    Bragg, J.R.; Prince, R.C.; Harner, J.; Atlas, R.M.

    1993-01-01

    Following the Exxon Valdez oil spill in 1989, extensive research was conducted by the US Environments Protection Agency and Exxon to develop and implement bioremediation techniques for oil spill cleanup. A key challenge of this program was to develop effective methods for monitoring and interpreting bioremediation effectiveness on extremely heterogenous intertidal shorelines. Fertilizers were applied to shorelines at concentrations known to be safe, and effectiveness achieved in acceleration biodegradation of oil residues was measure using several techniques. This paper describes the most definitive method identified, which monitors biodegradation loss by measuring changes in ratios of hydrocarbons to hopane, a cycloalkane present in the oil that showed no measurable degradation. Rates of loss measured by the hopane ratio method have high levels of statistical confidence, and show that the fertilizer addition stimulated biodegradation rates as much a fivefold. Multiple regression analyses of data show that fertilizer addition of nitrogen in interstitial pore water per unit of oil load was the most important parameter affecting biodegradation rate, and results suggest that monitoring nitrogen concentrations in the subsurface pore water is preferred technique for determining fertilizer dosage and reapplication frequency

  15. STRUCTURAL AND FUNCTIONAL CHANGES EVALUATED BY ECHOCARDIOGRAPHY IN PATIENTS WITH SYSTEMIC SCLEROSIS AND HEART RATE VARIABILITY

    Directory of Open Access Journals (Sweden)

    E. O. Saad

    2017-01-01

    Full Text Available Objective: to estimate heart rate variability (HRV in patients with systemic sclerosis (SS and to investigate their relationship to echocardiographic structural and functional changes in the heart.Subjects and methods. The investigation enrolled 125 patients with SS and 50 gender- and age-matched apparently healthy individuals who made up a control group. In addition to clinical examinations, 73 patients underwent HRV assessment from 24-hour Holter electrocardiogram (ECG monitoring results and 121 patients had echocardiography (EchoCG. 24-hour Holter ECG monitoring was carried out in all control individuals.Results and discussion. Examination of the main parameters of time-domain HRV in patients with SS revealed a significant decline in all temporal and spectral indices, except for the mean R–R interval duration (meanNN, as compared with the control group. EchoCG detected a variety of changes, primarily the induration and calcification of aortic and mitral valves in most patients. Left ventricular diastolic dysfunction was encountered in almost half of the patients with SS. Eight patients had a lower left ventricular ejection fraction (LVEF, which was <55%. Studying the association of HRV values with separate EchoCG parameters revealed significant inverse correlations of the mean standard deviation of R–R intervals in 5-minute recording segments during 24 hours with the thickness of the interventricular septum (r = -0.18; p < 0.05 and with the induration of the aortic valve (r = -0.18; p < 0.05; the square root mean squared of successive differences (RMSSD, ms for R–R intervals and the percentage of adjacent R–R intervals that varied by more than 50 ms (pNN50 correlated with the induration of the aortic valve (r = -0.23; p<0.05 and r = -0.25; p < 0.05, respectively, with the presence of pericarditis (r = -0.24; p < 0.05 and r = -0,27; p < 0.05, respectively, and with the level of pulmonary artery systolic pressure (r = -0

  16. Automatic ingestion monitor: a novel wearable device for monitoring of ingestive behavior.

    Science.gov (United States)

    Fontana, Juan M; Farooq, Muhammad; Sazonov, Edward

    2014-06-01

    Objective monitoring of food intake and ingestive behavior in a free-living environment remains an open problem that has significant implications in study and treatment of obesity and eating disorders. In this paper, a novel wearable sensor system (automatic ingestion monitor, AIM) is presented for objective monitoring of ingestive behavior in free living. The proposed device integrates three sensor modalities that wirelessly interface to a smartphone: a jaw motion sensor, a hand gesture sensor, and an accelerometer. A novel sensor fusion and pattern recognition method was developed for subject-independent food intake recognition. The device and the methodology were validated with data collected from 12 subjects wearing AIM during the course of 24 h in which both the daily activities and the food intake of the subjects were not restricted in any way. Results showed that the system was able to detect food intake with an average accuracy of 89.8%, which suggests that AIM can potentially be used as an instrument to monitor ingestive behavior in free-living individuals.

  17. Remote monitoring in international safeguards

    International Nuclear Information System (INIS)

    Dupree, S.A.; Sonnier, C.S.; Johnson, C.S.

    1996-01-01

    In recent years, technology that permits the integration of monitoring sensors and instruments into a coherent network has become available. Such integrated monitoring systems provide a means for the automatic collection and assessment of sensor signals and instrument readings and for processing such signals and readings in near real time. To gain experience with the new monitoring system technology, the US Department of energy, through bilateral agreements with its international partners, has initiated a project to emplace demonstration systems in various nuclear facilities and conduct field trials of the technology. This effort is the International Remote Monitoring Project. Under this project, remote monitoring systems are being deployed around the world in an incremental manner. Each deployment is different and each offers lessons for improving the performance and flexibility of the technology. Few problems were encountered with the operation of the installations to date, and much has been learned about the operation and use of the new technology. In the future, the authors believe systems for safeguards applications should be capable of being monitored remotely, emphasize the use of sensors, and utilize selective triggering for recording of images. Remote monitoring across national borders can occur only in the context of a cooperative, nonadversarial implementation regime. However, significant technical and policy work remains to be done before widespread safeguards implementation of remote monitoring should be considered. This paper shows that an abundance of technology supports the implementation of integrated and remote monitoring systems. Current field trials of remote monitoring systems are providing practical data and operational experience to aid in the design of tomorrow's systems

  18. Monitor of dynamic parameters in real time; Monitor de parametros dinamicos en tiempo real

    Energy Technology Data Exchange (ETDEWEB)

    Rojas S, A.S.; Ruiz E, J.A. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2008-07-01

    In the complex physical systems exist parameters that are necessary for monitoring in real time. In the nuclear industry, particularly in a reactor this surveillance is important, where the times of the reactions are almost instantaneous. Although many of these parameters are monitored, given the advance of the computer systems the monitoring could either be enlarged direct or indirect of other parameters. The analysis of the neutron noise in the nuclear reactors, plays an important role, the noise signal it contains information about the operation conditions of a system, when analyzing it with analysis methodologies of analogical signals to provide important information for the early detection of possible flaws and to indicate the permissible operation levels. To show the characteristics of the operation of the system of Monitoring of Dynamic Parameters in Real Time, oscillations of neutron noise of the TRIGA Mark III of the ININ were analyzed, these were caused with the control bar to a power of 10 Watts, the oscillations were carried out to a frequency of 1Hz, signal of low frequency. In this work a virtual instrument that allows by means of the spectral analysis method in frequency point by point is presented, to indicate in real time periodic variations that could be presented in the neutron noise signal, visualizing in advance the dynamic behavior of the system or nuclear plant. Another of the tests of the monitoring system presented is that of the oscillatory event happened in the reactor of Laguna Verde Nucleo electric Central, would be convenient to have an instrument of surveillance for monitoring through the neutron noise signal the behavior of some important parameter to predict and to indicate in an immediate way an abnormal condition in the reactor operation or in the plant system. These parameters can be the power, the recirculation water flow, etc. The monitor is based on a personal computer (PC), a data acquisition card (ADC) and a computer program

  19. Subjective video quality comparison of HDTV monitors

    Science.gov (United States)

    Seo, G.; Lim, C.; Lee, S.; Lee, C.

    2009-01-01

    HDTV broadcasting services have become widely available. Furthermore, in the upcoming IPTV services, HDTV services are important and quality monitoring becomes an issue, particularly in IPTV services. Consequently, there have been great efforts to develop video quality measurement methods for HDTV. On the other hand, most HDTV programs will be watched on digital TV monitors which include LCD and PDP TV monitors. In general, the LCD and PDP TV monitors have different color characteristics and response times. Furthermore, most commercial TV monitors include post-processing to improve video quality. In this paper, we compare subjective video quality of some commercial HD TV monitors to investigate the impact of monitor type on perceptual video quality. We used the ACR method as a subjective testing method. Experimental results show that the correlation coefficients among the HDTV monitors are reasonable high. However, for some video sequences and impairments, some differences in subjective scores were observed.

  20. Effect of verapamil on heart rate variability after an acute myocardial infarction. Danish Verapamil Infarction Trial II

    DEFF Research Database (Denmark)

    Vaage-Nilsen, M; Rasmussen, Verner

    1998-01-01

    with verapamil significantly reduced sudden death, the aim of the present substudy was to evaluate the effect of verapamil on heart-rate variability in the time and frequency domain, measured in two 5-minute segments during the day and night. Thirty-eight patients were examined by Holter monitoring, at 1 week......-16 months of treatment. In accord with the known reduction of overall heart rate by verapamil, a significant increase of mean NN interval from before to after 1 (P = 0.0004) and 12-16 months (P = 0.004) of treatment was seen in the verapamil, but not in the placebo, group at night. Parameters generally......, the present study indicates that verapamil shifts the autonomic balance to a vagal preponderance or sympathetic attenuation in the postinfarction period....

  1. Relationship between vascular dysfunction in peripheral arteries and ischemic episodes during daily life in patients with ischemic heart disease and hypercholesterolemia

    DEFF Research Database (Denmark)

    Søndergaard, Eva; Møller, Jacob E; Egstrup, Kenneth

    2002-01-01

    cardiovascular risk factors. CONCLUSIONS: These results indicate a significant relationship between ischemic episodes and vascular dysfunction in patients with ischemic heart disease and hypercholesterolemia and may justify an aggressive preventive therapy targeted directly at the endothelium.......BACKGROUND: It is well established that endothelial dysfunction is present in patients with ischemic heart disease and hypercholesterolemia. Some of these patients will have signs of transient myocardial ischemia during Holter monitoring. We sought to describe the correlation between daily life...... ischemia and signs of endothelial dysfunction as assessed by means of brachial vasoreactivity. METHODS: We included in the study 131 patients with documented ischemic heart disease and a serum cholesterol level of > or =5 mmol/L before the institution of lipid-lowering treatment and dietary intervention...

  2. Digital radiography with computerized conventional monitors compared to medical monitors in vertical root fracture diagnosis.

    Science.gov (United States)

    Tofangchiha, Maryam; Adel, Mamak; Bakhshi, Mahin; Esfehani, Mahsa; Nazeman, Pantea; Ghorbani Elizeyi, Mojgan; Javadi, Amir

    2013-01-01

    Vertical root fracture (VRF) is a complication which is chiefly diagnosed radiographically. Recently, film-based radiography has been substituted with digital radiography. At the moment, there is a wide range of monitors available in the market for viewing digital images. The present study aims to compare the diagnostic accuracy, sensitivity and specificity of medical and conventional monitors in detection of vertical root fractures. In this in vitro study 228 extracted single-rooted human teeth were endodontically treated. Vertical root fractures were induced in 114 samples. The teeth were imaged by a digital charge-coupled device radiography using parallel technique. The images were evaluated by a radiologist and an endodontist on two medical and conventional liquid-crystal display (LCD) monitors twice. Z-test was used to analyze the sensitivity, accuracy and specificity of each monitor. Significance level was set at 0.05. Inter and intra observer agreements were calculated by Cohen's kappa. Accuracy, specificity and sensitivity for conventional monitor were calculated as 67.5%, 72%, 62.5% respectively; and data for medical grade monitor were 67.5%, 66.5% and 68% respectively. Statistical analysis showed no significant differences in detecting VRF between the two techniques. Inter-observer agreement for conventional and medical monitor was 0.47 and 0.55 respectively (moderate). Intra-observer agreement was 0.78 for medical monitor and 0.87 for conventional one (substantial). The type of monitor does not influence diagnosis of vertical root fractures.

  3. Radiation monitoring considerations for radiobiology facilities

    International Nuclear Information System (INIS)

    McClelland, T.W.; McFall, E.D.

    1976-01-01

    Battelle, Pacific Northwest Laboratories, conducts a wide variety of radiobiology and radioecology research in a number of facilities on the Hanford Reservation. Review of radiation monitoring problems associated with storage, plant and animal experiments, waste handling and sterile facilities shows that careful monitoring, strict procedural controls and innovative techniques are required to minimize occupational exposure and control contamination. Although a wide variety of radioactivity levels are involved, much of the work is with extremely low level materials. Monitoring low level work is mundane and often impractical but cannot be ignored in today's ever tightening controls

  4. Evaluation of computer tomograms using a black-and-white monitor and a colour monitor: A ROC comparison

    International Nuclear Information System (INIS)

    Rockstroh, G.; Rotte, K.H.; Kriedemann, E.

    1987-01-01

    Different views about the value of a colour monitor for the evaluation of computer tomograms have prompted us to carry out this ROC (Receiver Operation Characteristic) examination. The latter was based on patient computer tomograms in which lesions of the liver were simulated by image manipulation. 5 radiologists analysed the image material (a) on a black-and-white monitor, (b) on a colour monitor, and (c) simultaneously on a black-and-white and a colour monitor. The study shows that the use of a colour monitor gives no essentially different result than evaluation with a black-and-white monitor. The slightly better result of 2% more true positive findings with simultaneous representation of black-and-white and colour image relative to the sole use of black-and-white display is within error limits. The colour representation gives no advantages for the evaluation of usual computer tomograms because the window technique enables a contrasty representation in black-and-white too. (orig.) [de

  5. Monitoring of railway bridges in Japan

    Science.gov (United States)

    Abe, Makoto; Komon, Kazuki; Narumoto, Asao; Sugidate, Masao; Mori, Takeshi; Miki, Chitoshi

    2000-06-01

    In Japan, some monitoring systems have been introduced to evaluate conditions of the railway structures. In this work, we introduce the monitoring systems of railway bridges. Here, for example, we show the abstraction of fatigue damage monitoring system. The crack propagation properties of a side notched SUS304 thin sheet, which is affixed to a fatigue test specimen, is studied to develop a fatigue damage monitoring sensor. When cyclic loads are applied to the fatigue specimen, the side notched thin sheet behaves as a displacement controlled condition. The stress intensity factor (Delta) K is expressed by the following equation; (Delta) K equals (Delta) (sigma) (root)GL/2 where GL is the gauge length of the thin sheet. The thin sheet is fatigue pre-cracked, stress- relieved and affixed to a specimen. The results of fatigue crack propagation tests show that the crack propagation rate is dependent on stress range and gauge length, but not on crack length. Under sufficient mean stress conditions, the fatigue crack propagation rate is well expressed by a power low of (Delta) K even at such a low stress range as 20 MPa. Fatigue damage accumulated during a monitoring period can be estimated from crack propagation during the period. The sensitivity of the sensor is controlled through the gauge length of the sensor.

  6. Development of a PZT-based wireless digital monitor for composite impact monitoring

    International Nuclear Information System (INIS)

    Liu, Peipei; Yuan, Shenfang; Qiu, Lei

    2012-01-01

    One of the major concerns in the whole lifetime of composite materials in aircraft is their susceptibility to impact damage. And there has existed a need in recent years to develop an online structural health monitoring (SHM) system for impact monitoring. This paper proposes a new PZT-based wireless digital impact monitoring system development method aimed at giving a localized area for further inspection. Based on this method, a PZT-based wireless digital impact monitor (WDIM) with advantages of compactness, light weight, low power consumption and high efficiency is developed. Differently from conventional SHM systems, the complex analog circuits are removed and the whole process is achieved in a digital way by turning the output of the PZT sensor directly into a digital queue through a comparator. A simple but efficient sub-region location method is implemented in a field programmable gate array (FPGA) as the processing core of the WDIM to detect and record the impact events. In addition, wireless communication technology is used in the WDIM to transmit data and form a monitoring network. To illustrate the capability of the WDIM, a complete process dealing with an impact event is investigated and the stability of the WDIM is also evaluated in this paper. The WDIM shows its potential for real online applications in aircraft. (paper)

  7. Standard 12 Lead and 24 hour holter electrocardiographic ...

    African Journals Online (AJOL)

    Aim: To compare the cardiovascular responses to perinatal stress between two ethnic groups of newborns. Study population: 23 Nigerians and 14 Dutch perinally asphyxiated newborns together with their respective control of 12 healthy Nigerian and 16 Dutch newborns. Method: The study subjects and their controls were ...

  8. Monitoring of radioactive wastes

    International Nuclear Information System (INIS)

    Houriet, J.Ph.

    1982-08-01

    The estimation of risks presented by final disposal of radioactive wastes depends, among other things, on what is known of their radioisotope content. The first aim of this report is to present the current state of possibilities for measuring (monitoring) radionuclides in wastes. The definition of a global monitoring system in the framework of radioactive waste disposal has to be realized, based on the information presented here, in accordance with the results of work to come and on the inventory of wastes to be stored. Designed for direct measurement of unpackaged wastes and for control of wastes ready to be stored, the system would ultimately make it possible to obtain all adaquate information about their radioisotope content with regard to the required disposal safety. The second aim of this report is to outline the definition of such a global system of monitoring. Designed as a workbase and reference source for future work by the National Cooperative for the Storage of Radioactive Waste on the topic of radioactive waste monitoring, this report describes the current situation in this field. It also makes it possible to draw some preliminary conclusions and to make several recommendations. Centered on the possibilities of current and developing techniques, it makes evident that a global monitoring system should be developed. However, it shows that the monitoring of packaged wastes will be difficult, and should be avoided as far as possible, except for control measurements

  9. Monitoring as component for the decision making in final repository projects; Monitoring als Baustein fuer die Entscheidungsfindung in Endlagerprojekten

    Energy Technology Data Exchange (ETDEWEB)

    Kallenbach-Herbert, Beate; Alt, Stefan [Oeko-Institut e.V., Darmstadt (Germany)

    2012-12-15

    The monitoring in final radioactive waste repositories is performed by continuous or repeated measurements of technical and geologic parameters during long time periods. The collected data serve manifold purposes. The central focus is to provide fundamental information for the decision between and within the three phases of a final repository project. This means that monitoring is not only the sum of technical surveillance measures. Monitoring is also important for several sociopolitical decisions, for instance in case of closure of the repository. The article discusses possible objectives and shows the relevant technical aspects that are used deduce the requirements for an integrated monitoring concept. It is shown that a monitoring concept should be developed early enough involving all groups that are concerned by the waste disposal project.

  10. The effect of the physical activity on polymorphic premature ventricular complexes in chronic kidney disease

    Directory of Open Access Journals (Sweden)

    Márcio G. Kiuchi

    2017-06-01

    Full Text Available Background: Polymorphic premature ventricular complexes (PVCs are very common, appearing most frequently in patients with hypertension, obesity, sleep apnea, and structural heart disease. Sympathetic hyperactivity plays a critical role in the development, maintenance, and aggravation of ventricular arrhythmias. Endurance exercise training clearly lowers sympathetic activity in sympatho-excitatory disease states and may be tolerated by patients with chronic kidney disease (CKD. Methods: We assessed 40 CKD patients with hypertension with polymorphic PVCs. Patients underwent a complete medical history and physical examination. We evaluated the effectiveness of β blocker only or β blocker + exercise during 12 months of follow-up regarding the changes of the numbers of PVCs and mean heart rate (HR by 24-hour-Holter. Results: We observed in the β blocker group a significant decrease in the number of polymorphic PVCs from baseline 36,515 ± 3,518 to 3, 6, 9 and 12 months of follow-up, 28,314 ± 2,938, 23,709 ± 1,846, 22,564 ± 1,673, and 22,725 ± 1,415, respectively (P < 0.001. In the β blocker + exercise group a significant decrease in the number of polymorphic PVCs also occurred from baseline 36,091 ± 3,327 to 3, 6, 9 and 12 months of follow-up, 29,252 ± 3,211, 20,948 ± 2,386, 14,238 ± 3,338, and 6,225 ± 2,319, respectively (P < 0.001. Comparisons between the two groups at the same time point showed differences from the sixth month onwards: the 6th (Δ = −2,761, P = 0.045, 9th (Δ = −8,325, P < 0.001 and 12th (Δ = −16,500, P < 0.001 months. There was an improvement during the 12 months of follow-up vs. baseline, after the β blocker or β blocker + exercise in mean 24-hour HR Holter monitoring, creatinine values, eGFR, and ACR. Conclusion: Polymorphic PVCs may be modifiable by physical activity in CKD patients with hypertension without structural heart disease.

  11. Estimation of inhalation doses from airborne releases using gross monitors

    International Nuclear Information System (INIS)

    Goldstein, N.P.

    1978-01-01

    Monitoring programs at most nuclear facilities involve continuous gross measurements supplemented by periodic isotopic analyses of release samples. The isotopic measurements are required to accurately assess the potential dose from the various effluent streams, but in between these measurements, one depends on the gross monitors to provide approximate indications of the dose. The effluent streams release a variety of nuclides, each with its own dose factor. This means that the relationship between the counting rate in a gross monitor and the potential dose of the effluent being monitored will depend on the isotopic composition of this release. If this composition changes, then the dose indicated by the gross monitor (calibrated for the original group of isotopes) may be significantly in error. The problem of indicating inhalation doses from gross monitoring of airborne releases is considered. In order for this type of monitor to accurately indicate dose, regardless of the isotopic makeup of a release, the analysis shows that its response to each isotope should be proportional to the dose factor of that isotope. These ideas are applied to the monitoring of air particulates using gross beta and gross gamma monitors. The study shows that the former more closely satisfies this condition and as a result, satisfactorily indicates the actual dose from reactor effluents, as determined from detailed isotopic data published in the literature. On the other hand, the gross gamma monitor, with its poorer fit to the condition, provided less than satisfactory accuracy in its dose estimates. In addition, a variety of other mathematical response functions were considered but their dose estimation capabilities were not much better than the straight beta response. The study shows that reasonably accurate dose estimates can be made using properly selected gross monitors, but that significant errors can result with improper ones. (author)

  12. Pollution monitoring of puget sound with honey bees.

    Science.gov (United States)

    Bromenshenk, J J; Carlson, S R; Simpson, J C; Thomas, J M

    1985-02-08

    To show that honey bees are effective biological monitors of environmental contaminants over large geographic areas, beekeepers of Puget Sound, Washington, collected pollen and bees for chemical analysis. From these data, kriging maps of arsenic, cadmium, and fluoride were generated. Results, based on actual concentrations of contaminants in bee tissues, show that the greatest concentrations of contaminants occur close to Commencement Bay and that honey bees are effective as large-scale monitors.

  13. Diagnostic Dilemma of Cardiac Syncope in Pediatric Patients

    Directory of Open Access Journals (Sweden)

    Ranya A Hegazy

    2008-02-01

    Full Text Available Aims Syncope is defined as temporary loss of consciousness and postural tone resulting from an abrupt transient decrease in cerebral blood flow. The present work aimed at determining how diagnostic tests are used in the evaluation of pediatric syncope at a tertiary pediatric referral center and to report on the utility and the yield of these tests.Settings and Design Retrospective study conducted at a tertiary referral arrhythmolology serviceMethods and Material The clinical charts of 234 pediatric patients presenting with a primary complaint of syncope with an average age of 7.48 ± 3.82(3.5-16 years were reviewed by the investigators.Statistical analysis used Statistical Package of social science (SPSS version 9,0 was used for analysis of data.Results The commonest trigger for syncope in the study population was early following exercise (n=65 and the commonest prodrome was palpitation, noted in 25 patients. A murmur was present in 19 of our patients (8.3% while 10.7% (n=25 had abnormal ECGs. Of the 106 echocardiograms done, 14 (13.2% were abnormal. Only two of them were missed by ECG. All patients were offered ambulatory 24 hour ECG. One patient with sick sinus syndrome was diagnosed only with Holter.Conclusions Clues to the presence of cardiac syncope may include acute onset of syncope, frequent episodes, low difference between blood pressure readings in supine and erect positions (after standing for 2 minutes and most importantly an abnormal 12 lead ECG. Transthoracic echo and Holter monitoring have low yield in pediatric syncope.

  14. Detection of atrial fibrillation and flutter by a dual-chamber implantable cardioverter-defibrillator. For the Worldwide Jewel AF Investigators.

    Science.gov (United States)

    Swerdlow, C D; Schsls, W; Dijkman, B; Jung, W; Sheth, N V; Olson, W H; Gunderson, B D

    2000-02-29

    To distinguish prolonged episodes of atrial fibrillation (AF) that require cardioversion from self-terminating episodes that do not, an atrial implantable cardioverter-defibrillator (ICD) must be able to detect AF continuously for extended periods. The ICD should discriminate between atrial tachycardia/flutter (AT), which may be terminated by antitachycardia pacing, and AF, which requires cardioversion. We studied 80 patients with AT/AF and ventricular arrhythmias who were treated with a new atrial/dual-chamber ICD. During a follow-up period lasting 6+/-2 months, we validated spontaneous, device-defined AT/AF episodes by stored electrograms in all patients. In 58 patients, we performed 80 Holter recordings with telemetered atrial electrograms, both to validate the continuous detection of AT/AF and to determine the sensitivity of the detection of AT/AF. Detection was appropriate in 98% of 132 AF episodes and 88% of 190 AT episodes (98% of 128 AT episodes with an atrial cycle length 1 hour, for a total of 2697 hours of continuous detection of AT/AF. During Holter monitoring, the sensitivity of the detection of AT/AF (116 hours) was 100%; the specificity of the detection of non-AT/AF rhythms (1290 hours) was 99.99%. Of 166 appropriate episodes detected as AT, 45% were terminated by antitachycardia pacing. A new ICD detects AT/AF accurately and continuously. Therapy may be programmed for long-duration AT/AF, with a low risk of underdetection. Discrimination of AT from AF permits successful pacing therapy for a significant fraction of AT.

  15. Overview of individual monitoring and calibration of radiation monitors in the country; Panorama da monitoração individual e calibração de monitores de radiação no país

    Energy Technology Data Exchange (ETDEWEB)

    Alencar, M.A.V.; Patrão, K.C.S.; Ferreira, P.R.R.; Matta, L.E.S.C.; Peres, S.S.; Silva, F.C.A. da, E-mail: vallim@ird.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Since 1995, the Institute of Radioprotection and Dosimetry (IRD/CNEN-RJ) has been responsible for the certification of instrument calibration laboratories and monitoring of occupationally exposed individuals (IOE), as well as monitoring and auditing the activities of eleven individual monitoring services (SMIE) and six instrument calibration laboratories (LCI) in the country. The work presents an overview of the number of IOE monitored and calibrated radiation monitors, from 2008 to 2016. The data were obtained through a census with the SMIE and LCI. The results show that in this period there was an increase of around 47% in the total number of IOE monitored and approximately 40% in the number of instrument calibrations. It was also observed the reduction of dosimetric film use and the beginning of OSLD monitoring.

  16. Summary of intensive monitoring for radionuclides in fishery products after Fukushima accident and comparison to the results of long term monitoring program in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Ken; Morita, Takami; Shigenobu, Yuya; Takagi, Kaori; Miki, Shizuho; Kaeriyama, Hideki; Ambe, Daisuke; Ono, Tsuneo [National Research Institute of Fisheries Science, Fisheries Research Agency, 2-12-4, Fukuura, Kanazawa, Yokohama, Kanagawa 236-8648 (Japan)

    2014-07-01

    Monitoring of artificial radionuclides in fishery products started in late 1950's and has over half a century history in Japan. Fisheries Agency (FA), Fisheries Research Agency (FRA) and prefectural organizations have been conducting the monitoring. The intensive monitoring of radioactive material in fishery products started in the late of March 2011 immediately after the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident for the coastal area faced to the Pacific Ocean in the eastern area of Japan and for the offshore area. The purpose of this monitoring is to avoid the distribution of fishery products containing radioactive cesium in concentration over the Japanese standard limit (Cs-134+Cs-137: 100 Bq/kg). Japanese monitoring data are opened to public on the FA's and FRA's web page. In this study, we resume the results of intensive monitoring started in 2011 and show the temporal change of concentration of radioactive cesium in fishery product. In Fukushima Prefecture, the ratio of samples exceeding the Japanese standard limit shows a steadily decreasing trend from 53% at Mar.- Jun. 2011 to below 3% at Jul. - Sep. 2013. In other prefectures, the ratio was 6.5% at Mar.- Jun. 2011 and fell gradually, and it has been below to 1% at Jul. - Sep. 2013. In presentation, we show the results of monitoring conducted in the coastal area and deeper water around Japan from long gamma ray measurements with ashed samples by high purified germanium gamma spectrometry. (authors)

  17. Tritium Room Air Monitor Operating Experience Review

    Energy Technology Data Exchange (ETDEWEB)

    L. C. Cadwallader; B. J. Denny

    2008-09-01

    Monitoring the breathing air in tritium facility rooms for airborne tritium is a radiological safety requirement and a best practice for personnel safety. Besides audible alarms for room evacuation, these monitors often send signals for process shutdown, ventilation isolation, and cleanup system actuation to mitigate releases and prevent tritium spread to the environment. Therefore, these monitors are important not only to personnel safety but also to public safety and environmental protection. This paper presents an operating experience review of tritium monitor performance on demand during small (1 mCi to 1 Ci) operational releases, and intentional airborne inroom tritium release tests. The tritium tests provide monitor operation data to allow calculation of a statistical estimate for the reliability of monitors annunciating in actual tritium gas airborne release situations. The data show a failure to operate rate of 3.5E-06/monitor-hr with an upper bound of 4.7E-06, a failure to alarm on demand rate of 1.4E-02/demand with an upper bound of 4.4E-02, and a spurious alarm rate of 0.1 to 0.2/monitor-yr.

  18. Intermittent versus Persistent Wolff-Parkinson-White Syndrome in Children: Electrophysiologic Properties and Clinical Outcomes.

    Science.gov (United States)

    Kiger, Michelle E; McCanta, Anthony C; Tong, Suhong; Schaffer, Michael; Runciman, Martin; Collins, Kathryn K

    2016-01-01

    Intermittent Wolff-Parkinson-White (WPW) syndrome is considered to have a lower risk of sudden death. Fewer data exist regarding electrophysiologic (EP) characteristics and the natural history of intermittent WPW in children. All patients with WPW age 1-18 years at a single institution (1996-2013) were reviewed. Patients with intermittent preexcitation were compared to those with loss of preexcitation on Holter/exercise testing and those with persistent preexcitation. High-risk accessory pathway (AP) was defined as AP effective refractory period (APERP), block cycle length, or shortest preexcited RR interval during atrial fibrillation ≤250 ms. A total of 295 patients were included: 226 (76.6%) persistent, 39 (13.2%) intermittent, and 30 (10.2%) loss of preexcitation Holter/exercise. There were no differences in symptoms between groups. Median interquartile range APERP was significantly longer in intermittent WPW (380 [320, 488] ms vs 320 [300, 350] ms persistent, 310 [290, 330] ms loss of preexcitation Holter/exercise; P = 0.0008). At baseline, there was no difference between groups in frequency of high-risk pathways. However, when isoproterenol values were included, high-risk pathways were more frequent among patients with loss of preexcitation on Holter/exercise (54% vs 16% persistent, 11% intermittent; P = 0.005). There was one death in a patient with loss of preexcitation on exercise testing, no EP study, and prior drug use. A second patient with persistent WPW and APERP 270 ms required resuscitation following a methadone overdose. Intermittent preexcitation in children does not connote a lower risk AP by EP criteria or reduced symptoms. The low number of pediatric WPW patients who develop preexcited atrial fibrillation or sudden death warrants larger studies to investigate these outcomes. ©2015 Wiley Periodicals, Inc.

  19. EVALUACIÓN DE LA DINÁMICA CARDIACA DE PACIENTES CON ARRITMIA CON BASE EN LA TEORÍA DE LA PROBABILIDAD

    Directory of Open Access Journals (Sweden)

    Javier Rodríguez

    2012-01-01

    Full Text Available Teorías físicas y matemáticas como los siste-mas dinámicos y la teoría de la probabilidad han servido como base para el desarrollo de metodo-logías diagnósticas en medicina. En este trabajo se aplicaron parámetros de evaluación asociados al número de latidos por hora, establecidos en un trabajo diagnóstico previo, a Holter de 16 pacientes con diferentes arritmias cardiacas, 3 con indicaciones de sintomatologías o patologías previas diagnos-ticados como normales y 1 normal, con edades mayores a 21 años, para estudiar la respuesta de estos parámetros a esta patología específica. Se calculó la probabilidad del número total de latidos por hora en rangos de 250 latidos/hora, evaluando la presencia de una probabilidad máxima menor a 0,217 o mayor a 0,304 y la aparición de un número menor a 3,000 o mayor a 6,250 latidos/ hora, encontrando que 12 de los holter con arritmia presentaron como mínimo una de las dos condicio-nes mencionadas, del mismo modo que los holter con antecedentes de sintomatologías o patologías previas y con diagnóstico dentro de los límites de normalidad, mientras que el holter de normalidad no presentó ninguna de estas condiciones.Los parámetros evaluados asociados a la probabilidad del número de latidos caracterizan objetivamente la dinámica cardiaca y sugieren una posible utilidad para la detección de alteraciones leves o en evolución hacia la enfermedad, siendo necesarios estudios posteriores para definir su aplicación clínica en arritmias.

  20. Monitoring: The missing piece

    Energy Technology Data Exchange (ETDEWEB)

    Bjorkland, Ronald, E-mail: r_bjorkland@hotmail.com

    2013-11-15

    The U.S. National Environmental Policy Act (NEPA) of 1969 heralded in an era of more robust attention to environmental impacts resulting from larger scale federal projects. The number of other countries that have adopted NEPA's framework is evidence of the appeal of this type of environmental legislation. Mandates to review environmental impacts, identify alternatives, and provide mitigation plans before commencement of the project are at the heart of NEPA. Such project reviews have resulted in the development of a vast number of reports and large volumes of project-specific data that potentially can be used to better understand the components and processes of the natural environment and provide guidance for improved and efficient environmental protection. However, the environmental assessment (EA) or the more robust and intensive environmental impact statement (EIS) that are required for most major projects more frequently than not are developed to satisfy the procedural aspects of the NEPA legislation while they fail to provide the needed guidance for improved decision-making. While NEPA legislation recommends monitoring of project activities, this activity is not mandated, and in those situations where it has been incorporated, the monitoring showed that the EIS was inaccurate in direction and/or magnitude of the impact. Many reviews of NEPA have suggested that monitoring all project phases, from the design through the decommissioning, should be incorporated. Information gathered though a well-developed monitoring program can be managed in databases and benefit not only the specific project but would provide guidance how to better design and implement future activities designed to protect and enhance the natural environment. -- Highlights: • NEPA statutes created profound environmental protection legislative framework. • Contrary to intent, NEPA does not provide for definitive project monitoring. • Robust project monitoring is essential for enhanced

  1. Long term pipeline monitoring in geomechanically sensitive environments

    Energy Technology Data Exchange (ETDEWEB)

    Weir-Jones, I.; Sun, M. [Weir-Jones Engineering Consultants Ltd. (Canada)

    2011-07-01

    In the oil industry, monitoring pipeline structural integrity is necessary for both regulatory and environmental purposes. Weir-Jones Engineering Consultants developed an automated structural integrity monitoring (SIM) system, data on strain, displacement and temperature are continuously acquired and automatically transmitted to the monitoring personnel. The aim of this paper is to present this technology and its implementation on one of Inter Pipeline Fund's lines as well. The automated SIM equipment was installed on a new 42'' line at the crossing of the Clearwater River close to Fort McMurray. Results showed that this technology is a good way to monitor pipelines in remote locations, environmentally sensitive areas, river and embankment crossings and in locations where external forces can put the pipeline at risk; but it should not be used otherwise as that would not be cost effective. This paper described the developed automated SIM and showed that it should only be used in specific locations to be cost effective.

  2. 24 CFR 108.20 - Monitoring office responsibility for monitoring plans and reports.

    Science.gov (United States)

    2010-04-01

    ... documenting the implementation of the AFHM plan, including sales or rental reports, as required by the.... When sales or rental reports show that 20% of the units covered by the AFHM plan have been sold or... for monitoring plans and reports. 108.20 Section 108.20 Housing and Urban Development Regulations...

  3. High sensitivity on-line monitor for radioactive effluent

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, Toshimi [Tohoku Electric Power Co. Ltd., Sendai (Japan); Ishizuka, Akira; Abe, Eisuke; Inoue, Yasuhiko; Fujii, Masaaki; Kitaguchi, Hiroshi; Doi, Akira

    1983-04-01

    A new approach for a highly sensitive effluent monitor is presented. The free flow type monitor, which consists of a straightener, nozzle, monitoring section and ..gamma..-ray detector, is demonstrated to be effective in providing long term stability. The 160 start-and-stop cycles of effluent discharge were repeated in a 120-h testing period. Results showed a background increase was not observed for the free flow type monitor. The background count rate was calibrated to the lowest detection limit to be 2.2 x 10/sup -2/ Bq/ml for a 300 s measurement time.

  4. Wetland Mitigation Monitoring at the Fernald Preserve - 13200

    Energy Technology Data Exchange (ETDEWEB)

    Powell, Jane [Fernald Preserve Site Manager, DOE Office of Legacy Management, Harrison, Ohio (United States); Bien, Stephanie; Decker, Ashlee; Homer, John [Environmental Scientist, S.M. Stoller Corporation, Harrison, Ohio (United States); Wulker, Brian [Intern, S.M. Stoller Corporation, Harrison, Ohio (United States)

    2013-07-01

    The U.S. Department of Energy is responsible for 7.2 hectares (17.8 acres) of mitigation wetland at the Fernald Preserve, Ohio. Remedial activities affected the wetlands, and mitigation plans were incorporated into site-wide ecological restoration planning. In 2008, the Fernald Natural Resource Trustees developed a comprehensive wetland mitigation monitoring approach to evaluate whether compensatory mitigation requirements have been met. The Fernald Preserve Wetland Mitigation Monitoring Plan provided a guideline for wetland evaluations. The Ohio Environmental Protection Agency (Ohio EPA) wetland mitigation monitoring protocols were adopted as the means for compensatory wetland evaluation. Design, hydrologic regime, vegetation, wildlife, and biogeochemistry were evaluated from 2009 to 2011. Evaluations showed mixed results when compared to the Ohio EPA performance standards. Results of vegetation monitoring varied, with the best results occurring in wetlands adjacent to forested areas. Amphibians, particularly ambystomatid salamanders, were observed in two areas adjacent to forested areas. Not all wetlands met vegetation performance standards and amphibian biodiversity metrics. However, Fernald mitigation wetlands showed substantially higher ratings compared to other mitigated wetlands in Ohio. Also, soil sampling results remain consistent with other Ohio mitigated wetlands. The performance standards are not intended to be 'pass/fail' criteria; rather, they are reference points for use in making decisions regarding future monitoring and maintenance. The Trustees approved the Fernald Preserve Wetland Mitigation Monitoring Report with the provision that long-term monitoring of the wetlands continues at the Fernald Preserve. (authors)

  5. Wetland Mitigation Monitoring at the Fernald Preserve - 13200

    International Nuclear Information System (INIS)

    Powell, Jane; Bien, Stephanie; Decker, Ashlee; Homer, John; Wulker, Brian

    2013-01-01

    The U.S. Department of Energy is responsible for 7.2 hectares (17.8 acres) of mitigation wetland at the Fernald Preserve, Ohio. Remedial activities affected the wetlands, and mitigation plans were incorporated into site-wide ecological restoration planning. In 2008, the Fernald Natural Resource Trustees developed a comprehensive wetland mitigation monitoring approach to evaluate whether compensatory mitigation requirements have been met. The Fernald Preserve Wetland Mitigation Monitoring Plan provided a guideline for wetland evaluations. The Ohio Environmental Protection Agency (Ohio EPA) wetland mitigation monitoring protocols were adopted as the means for compensatory wetland evaluation. Design, hydrologic regime, vegetation, wildlife, and biogeochemistry were evaluated from 2009 to 2011. Evaluations showed mixed results when compared to the Ohio EPA performance standards. Results of vegetation monitoring varied, with the best results occurring in wetlands adjacent to forested areas. Amphibians, particularly ambystomatid salamanders, were observed in two areas adjacent to forested areas. Not all wetlands met vegetation performance standards and amphibian biodiversity metrics. However, Fernald mitigation wetlands showed substantially higher ratings compared to other mitigated wetlands in Ohio. Also, soil sampling results remain consistent with other Ohio mitigated wetlands. The performance standards are not intended to be 'pass/fail' criteria; rather, they are reference points for use in making decisions regarding future monitoring and maintenance. The Trustees approved the Fernald Preserve Wetland Mitigation Monitoring Report with the provision that long-term monitoring of the wetlands continues at the Fernald Preserve. (authors)

  6. Facility effluent monitoring plan for 242-A Evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1993-03-01

    A facility effluent monitoring plan is required by the US Department of Energy in DOE Order 5400.1* for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility effluent Monitoring Plans, WHC-EP-0438-1**. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements

  7. Monitoring Forsmark. Bird monitoring in Forsmark 2010

    Energy Technology Data Exchange (ETDEWEB)

    Green, Martin (Dept. of Animal Ecology, Lund Univ. (Sweden))

    2010-12-15

    This report summarizes the monitoring of selected listed (Swedish Red List and/or the EU Birds Directive) breeding birds in Forsmark 2002-2010. Monitoring of eleven listed species was conducted in the regional model area, including the candidate area in 2010 in the same way as in earlier years. The results from the monitoring in 2010 differed somewhat from results gathered in earlier years. Most monitored species have increased in local numbers during the study years, and from most years continued increases have been reported. Between 2009 and 2010 most species (seven, 64% of the monitored ones) instead decreased in numbers. Only one species (honey buzzard) increased in numbers between the years and in this case this was probably more a result of small moves by certain pairs so that they this year had parts reaching into the regional model area, while in 2009 their territories were outside of this. No dramatic changes in bird numbers were however recorded and all the studied species show stable or increasing local populations over the study period. Number of Black-throated diver pairs was normal and breeding success was good this year. The breeding success of divers has improved considerably over the studied period and the patterns recorded in Forsmark closely follow recorded patterns at the national level. Honey buzzards and ospreys occurred in good numbers, above the average for the whole period, and breeding success was better than in 2009. Even if breeding success of honey buzzards is not monitored in any detail, there were still signs of at least a few successful breedings in the area this year. Breeding success of ospreys was below average, but still within the normal variation for most years. The local white-tailed eagles had a poor breeding season and no young at all were produced within the study area. All three grouse species (black grouse, capercaillie and hazelhen) decreased in numbers between 2009 and 2010. Note however that the large amounts of snow

  8. Monitoring Forsmark. Bird monitoring in Forsmark 2010

    International Nuclear Information System (INIS)

    Green, Martin

    2010-12-01

    This report summarizes the monitoring of selected listed (Swedish Red List and/or the EU Birds Directive) breeding birds in Forsmark 2002-2010. Monitoring of eleven listed species was conducted in the regional model area, including the candidate area in 2010 in the same way as in earlier years. The results from the monitoring in 2010 differed somewhat from results gathered in earlier years. Most monitored species have increased in local numbers during the study years, and from most years continued increases have been reported. Between 2009 and 2010 most species (seven, 64% of the monitored ones) instead decreased in numbers. Only one species (honey buzzard) increased in numbers between the years and in this case this was probably more a result of small moves by certain pairs so that they this year had parts reaching into the regional model area, while in 2009 their territories were outside of this. No dramatic changes in bird numbers were however recorded and all the studied species show stable or increasing local populations over the study period. Number of Black-throated diver pairs was normal and breeding success was good this year. The breeding success of divers has improved considerably over the studied period and the patterns recorded in Forsmark closely follow recorded patterns at the national level. Honey buzzards and ospreys occurred in good numbers, above the average for the whole period, and breeding success was better than in 2009. Even if breeding success of honey buzzards is not monitored in any detail, there were still signs of at least a few successful breedings in the area this year. Breeding success of ospreys was below average, but still within the normal variation for most years. The local white-tailed eagles had a poor breeding season and no young at all were produced within the study area. All three grouse species (black grouse, capercaillie and hazelhen) decreased in numbers between 2009 and 2010. Note however that the large amounts of snow

  9. Melatonin reduces cardiac morbidity and markers of myocardial ischemia after elective abdominal aortic aneurism repair

    DEFF Research Database (Denmark)

    Gögenür, Ismail; Kücükakin, Bülent; Panduro Jensen, Leif

    2014-01-01

    The aim was to examine the effect of perioperative melatonin treatment on clinical cardiac morbidity and markers of myocardial ischemia in patients undergoing elective surgery for abdominal aortic aneurism. Reperfusion injury results in increased cardiac morbidity in patients undergoing surgery...... for abdominal aortic aneurisms (AAA). A randomized, placebo-controlled, clinical trial including patients undergoing surgery for AAA was performed. The patients received by infusion over a 2-hr period either, 50 mg melatonin or placebo intra-operatively, and 10 mg melatonin or placebo orally, the first three...... by Holter monitoring. A total of 26 patients received melatonin, while 24 received placebo. A significant reduction in cardiac morbidity was seen in the melatonin-treated patients compared with those given placebo [4% versus 29% (P = 0.02)]. Five patients (19%) who received melatonin had increased Tp...

  10. C-reactive protein, heart rate variability and prognosis in community subjects with no apparent heart disease

    DEFF Research Database (Denmark)

    Sajadieh, A; Nielsen, OW; Rasmussen, Verner

    2006-01-01

    OBJECTIVES: Increased C-reactive protein (CRP) and reduced heart rate variability (HRV) both indicate poor prognosis. An inverse association between HRV and CRP has been reported, suggesting an interaction between inflammatory and autonomic systems. However, the prognostic impact of this interact...... of four HRV measures were significantly associated with increased rate of death or myocardial infarction. In a Cox model with CRP >or=2.5 microg mL(-1), standard deviation for the mean value of the time between normal complexes...... examinations, and 24-h Holter monitoring. Four time domain measures of HRV were studied. All were prospectively followed for up to 5 years. RESULTS: Mean age was 64 years (55-75). During the follow-up, 46 total deaths and 11 cases of definite acute myocardial infarction were observed. Both CRP and three...

  11. Severe abnormal Heart Rate Turbulence Onset is associated with deterioration of liver cirrhosis

    DEFF Research Database (Denmark)

    Jansen, Christian; Al-Kassou, Baravan; Lehmann, Jennifer

    2018-01-01

    BACKGROUND: In patients with liver cirrhosis, cardiac dysfunction is frequent and is associated with increased morbidity and mortality. Cardiac dysfunction in cirrhosis seems to be linked to autonomic dysfunction. This study investigates the role of autonomic dysfunction assessed by Heart Rate...... Turbulence (HRT) analyses in patients with liver cirrhosis. METHODS AND PATIENTS: Inclusion criteria was (1) diagnosis of cirrhosis by clinical, imaging or biopsy and (2) evaluation by standard 12-lead-ECG and 24h holter monitoring and (3) at least 3 premature ventricular contractions. The exclusion...... criterion was presence of cardiac diseases, independent of liver cirrhosis. Biochemical parameters were analysed using standard methods. HRT was assessed using Turbulence onset (TO) and slope (TS). The endpoint was deterioration of liver cirrhosis defined as increased MELD and readmission for complications...

  12. Development of web monitoring radiation area monitor

    International Nuclear Information System (INIS)

    Jung, Hoon Jin; Lee, Jun Hee; Namkoong, Phil; Lee, Dong Hoon; Lee, Su Hong; Lee, Gun Bae

    2005-01-01

    Recently the increasing number of radioisotope industry and nuclear facility have ever raised the possibility of radiation safety accident. As such a result, radioisotope companies and nuclear facility operators have become to be much interested in radiation area monitoring for efficient radiation protection. At present, almost of the radiation area monitors which are imported products are outdated in aspect of their functions. Diversification of the monitoring work is urgently demanding additional functions to be added. Thus we have developed new-type digital area monitor which enables remote web monitoring with image and radiation dose rate value at distant places through using internet, the latest IT technology, and radiation measurement technology

  13. Study of passive optical network monitoring based on non-OTDR

    Science.gov (United States)

    Li, Chuan-qi; Wang, Da-chi; Hu, Jin-lin

    2014-03-01

    Aiming at the defects of passive optical network (PON) monitoring based on optical time domain reflectometry (OTDR) technology, we research the non-OTDR monitoring technology. The coding scheme based on periodic encoder monitoring is discussed, and its limitation is analyzed. On this basis, the monitoring technology based on optical code division multiple access (OCDMA) is put forward. We analyze the feasibility of monitoring scheme based on PON of OCDMA, design a monitoring plan, and then use OptiSystem to simulate the design. The results of simulation and bit error rate (BER) analysis show that this monitoring technology can overcome the deficiencies of OTDR and distinguish the monitoring signals of different fiber branches clearly, which meets the demands for high beam split ratio of multi-user communication.

  14. Crack Monitoring of Operational Wind Turbine Foundations.

    Science.gov (United States)

    Perry, Marcus; McAlorum, Jack; Fusiek, Grzegorz; Niewczas, Pawel; McKeeman, Iain; Rubert, Tim

    2017-08-21

    The degradation of onshore, reinforced-concrete wind turbine foundations is usually assessed via above-ground inspections, or through lengthy excavation campaigns that suspend wind power generation. Foundation cracks can and do occur below ground level, and while sustained measurements of crack behaviour could be used to quantify the risk of water ingress and reinforcement corrosion, these cracks have not yet been monitored during turbine operation. Here, we outline the design, fabrication and field installation of subterranean fibre-optic sensors for monitoring the opening and lateral displacements of foundation cracks during wind turbine operation. We detail methods for in situ sensor characterisation, verify sensor responses against theoretical tower strains derived from wind speed data, and then show that measured crack displacements correlate with monitored tower strains. Our results show that foundation crack opening displacements respond linearly to tower strain and do not change by more than ±5 μ m. Lateral crack displacements were found to be negligible. We anticipate that the work outlined here will provide a starting point for real-time, long-term and dynamic analyses of crack displacements in future. Our findings could furthermore inform the development of cost-effective monitoring systems for ageing wind turbine foundations.

  15. Sympathetic overactivity and arrhythmias in tetanus: electrocardiographic analysis Hiperatividade simpática e arritmias no tétano: análise eletrocardiográfica

    Directory of Open Access Journals (Sweden)

    Gustavo Trindade Henriques Filho

    2007-02-01

    Full Text Available As a result of the advances in the control of pulmonary insufficiency in tetanus, the cardiovascular system has increasingly been shown to be a determining factor in morbidity and mortality but detailed knowledge of the cardiovascular complications in tetanus is scanty. The 24h-Holter was carried out in order to detect arrhythmias and sympathetic overactivity in 38 tetanus patients admitted to an ICU. The SDNN Index (standard deviation from the normal R-to-R intervals, was useful in detecting adrenergic tonus, and ranged from 64.1 ± 27 in the more severe forms of tetanus to 125 ± 69 in the milder ones. Sympathetic overactivity occurred in 86.2% of the more severe forms of the disease, but was also detected in 33% of the milder forms. Half the patients had their sympathetic overactivity detected only by the Holter. The most frequent arrhythmias were isolated supraventricular (55.2% and ventricular (39.4% extrasystoles. There was no association of the arrhythmias with the clinical form of tetanus or with the presence of sympathetic overactivity. The present study demonstrated that major cardiovascular dysfunction, particularly sympathetic overactivity, occurs in all forms of tetanus, even in the milder ones. This has not been effectively detected with traditional monitoring in ICU and may not be properly treated.Com os avanços no controle da insuficiência respiratória no tétano, o sistema cardiovascular tem participado de forma crescente na morbidade e mortalidade da doença, mas o conhecimento dessas complicações é escasso. No intuito de detectar arritmias e hiperatividade simpática, o holter de 24 h foi utilizado em 38 pacientes com tétano admitidos numa UTI de doenças infecciosas. O índice SDNN (desvio standard dos intervalos normais R-a-R, foi útil na detecção do tônus adrenérgico, e variou de 64,1 ± 27 nas formas mais severas de tétano a 125 ± 69 nas formas mais leves. Hiperatividade simpática ocorreu em 86,2% das formas

  16. Bunch monitor for an S-band electron linear accelerator

    International Nuclear Information System (INIS)

    Otake, Yuji; Nakahara, Kazuo

    1991-01-01

    The measurement of bunch characteristics in an S-band electron linear accelerator is required in order to evaluate the quality of accelerated electron beams. A new-type bunch monitor has been developed which combines micro-stripline technology with an air insulator and wall-current monitoring technology. The obtained time resolution of the monitor was more than 150 ps. This result shows that the monitor can handle the bunch number of an S-band linac. The structure of the monitor is suitable for being installed in the vacuum area, since it is constructed of only metal and ceramic parts. It can therefore easily be employed in an actual machine

  17. Radiation monitoring

    International Nuclear Information System (INIS)

    Larsson, L.Eh.; B'yuli, D.K.; Karmikel, Dzh.Kh.E.

    1985-01-01

    Recommendations on radiation monitoring of personnel, used medical ionizing radiation source, are given. The necessity to carry out radiation monitoring of situation at medical personnel's positions and personnel dosimetry is marked. It is convenient to subdivide radiation monitoring into 3 types: usual, surgical and special. Usual monitoring is connected with current work; surgical monitoring is carried out to receive information during a concrete operation; special monitoring is used to detect possible deviation from standard conditions of work or when suspecting them

  18. Global Monitoring for Food Security and Sustainable Land Management - Recent Advances of Remote Sensing Applications to African and Siberian Show Cases

    Science.gov (United States)

    Komp, K. U.; Haub, C.

    2012-07-01

    After four decades of space borne remote sensing, the unmapped white patches have mostly disappeared. Those basic information give the foundations to the observation of changes and even the introduction of monitoring programmes for a various number of features in the natural and human landscape of our planet. Recent indicators for climatic change together with worrisome alterations in regional food production versus the constantly increase of human population demand the design and implementation of reliable land management tools which will serve the food security as well as the sustainable use of resources of the ecosystem in its respective regional context. The positive responses and convincing results of ESA service elements in the efforts towards food security in several African countries have been the basis for the transfer of the methods into another region, the Western Siberian corn-belt. The large extends of cropping schemes in West Siberia demand advanced remote sensing methods to be applied in order to compare the impacts of climatic change not only on the agricultural production but also on risks for the ecosystem. A multi scale approach of remote sensing methods is introduced in analogy to the African activities. An adopted monitoring concept is developed using a nearly daily product of medium resolution for wide areas, high resolution sensors for stratified sample areas and in-situ observations. Beyond methodological research, the ability of remote sensing is contributing to operational solutions that can ensure the nutritional and ecological future of our planet.

  19. Configuration of Risk Monitor System by PLant Defense-In.Depth Monitor and Relability Monitor

    DEFF Research Database (Denmark)

    Yoshikawa, Hidekazu; Lind, Morten; Yang, Ming

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability...... monitor derived from the four aspects of (i) design principle of nuclear safety to realize DiD concept, (ii) definition of risk and risk to be monitored, (iii) severe accident phenomena as major risk, (iv) scheme of risk ranking, and (v) dynamic risk display. In this paper, the overall frame...... of the proposed frame on risk monitor system is summarized and the detailed discussion is made on the definitions of major terminologies of risk, risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor and its example...

  20. Risk factors for persistent atrial fibrillation following successful hyperthyroidism treatment with radioiodine therapy.

    Science.gov (United States)

    Zhou, Zhen-Hu; Ma, Long-Le; Wang, Le-Xin

    2011-01-01

    To investigate the predicting factors for persistent atrial fibrillation (AF) following radioiodine therapy for hyperthyroidism. Standard 12-lead ECG and 24-h Holter monitoring were performed in 94 patients (38 males, mean age 46.1±8.2 years) with persistent AF following radioiodine therapy for hyperthyroidism. Left ventricular (LV) function was assessed with two-dimensional echocardiography. Euthyroidism or hypothyroidism was achieved in 81% and 19% of the patients, respectively, after radioiodine therapy. At the end of follow-up (1.6±1.3 years), LV ejection fraction in the 52 patients with LV dysfunction was increased from 39.3±3.3% to 59.0±5.5% (ptreatment paroxysmal AF, no AF was documented during the follow-up. In the 45 patients with pre-treatment persistent AF, AF was found in 27 (60%) during the follow-up. Multivariate logistic regression analysis showed that more than 55 years old in age (RR 2.76, 95% CI: 1.16-8.79, phyperthyroidism (RR 3.08, 95% CI: 1.22-11.41, ptreatment atrial fibrillation (RR 2.96, 95% CI: 1.31-7.68, phyperthyroidism and pre-treatment duration of AF are risk factors for persistent AF following radioiodine therapy.

  1. Impact of space weather on human heart rate during the years 2011-2013

    Science.gov (United States)

    Galata, E.; Ioannidou, S.; Papailiou, M.; Mavromichalaki, H.; Paravolidakis, K.; Kouremeti, M.; Rentifis, L.; Simantirakis, E.; Trachanas, K.

    2017-08-01

    During the last years a possible link between different levels of solar and geomagnetic disturbances and human physiological parameters is suggested by several published studies. In this work the examination of the potential association between heart rate variations and specific space weather activities was performed. A total of 482 individuals treated at Hippocratio General Hospital in Athens, the Cardiology clinics of Nikaia General Hospital in Piraeus and the Heraklion University Hospital in Crete, Greece, were assessed from July 2011 to April 2013. The heart rate of the individuals was recorded by a Holter monitor on a n hourly basis, while the hourly variations of the cosmic ray intensity measured by the Neutron Monitor Station of the Athens University and of the geomagnetic index Dst provided by the Kyoto Observatory were used. The ANalysis Of VAriance (ANOVA) and the Multiple Linear Regression analysis were used for analysis of these data. A statistically significant effect of both cosmic rays and geomagnetic activity on heart rate was observed, which may indicate that changes in space weather could be linked to heart rate variations.

  2. Wireless pilot monitoring system for extreme race conditions.

    Science.gov (United States)

    Pino, Esteban J; Arias, Diego E; Aqueveque, Pablo; Melin, Pedro; Curtis, Dorothy W

    2012-01-01

    This paper presents the design and implementation of an assistive device to monitor car drivers under extreme conditions. In particular, this system is designed in preparation for the 2012 Atacama Solar Challenge to be held in the Chilean desert. Actual preliminary results show the feasibility of such a project including physiological and ambient sensors, real-time processing algorithms, wireless data transmission and a remote monitoring station. Implementation details and field results are shown along with a discussion of the main problems found in real-life telemetry monitoring.

  3. Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 2, Radiation Monitoring and Sampling

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Aerial Measurement Systems

    2012-07-31

    The FRMAC Monitoring and Sampling Manual, Volume 2 provides standard operating procedures (SOPs) for field radiation monitoring and sample collection activities that are performed by the Monitoring group during a FRMAC response to a radiological emergency.

  4. Clinical validation of a medical grade color monitor for chest radiology

    Science.gov (United States)

    Jacobs, J.; Zanca, F.; Verschakelen, J.; Marchal, G.; Bosmans, H.

    2009-02-01

    Until recently, the specifications of medical grade monochrome LCD monitors outperformed those of color LCD monitors. New generations of color LCD monitors, however, show specifications that are in many respects similar to those of monochrome monitors typically used in diagnostic workstations. The aim of present study was to evaluate the impact of different medical grade monitors in terms of detection of simulated lung nodules in chest x-ray images. Specifically, we wanted to compare a new medical grade color monitor (Barco Coronis 6MP color) to a medical grade grayscale monitor (Barco Coronis 3MP monochrome) and a consumer color monitor (Philips 200VW 1.7MP color) by means of an observer performance experiment. Using the free-response acquisition data paradigm, seven radiologists were asked to detect and locate lung nodules (170 in total), simulated in half of the 200 chest X-ray images used in the experiment. The jackknife free-response receiver operating characteristic (JAFROC) analysis of the data showed a statistically significant difference between at least two monitors, F-value=3.77 and p-value =0.0481. The different Figure of Merit values were 0.727, 0.723 and 0.697 for the new color LCD monitor, the medical grade monitor and the consumer color monitor respectively. There was no difference between the needed reading times but there was a difference between the mean calculated Euclidian distances between the position marked by the observers and the center of the simulated nodule, indicating a better accuracy with both medical grade monitors. Present data suggests that the new generation of medical grade color monitors could be used as diagnostic workstations.

  5. A Bridge Deflection Monitoring System Based on CCD

    Directory of Open Access Journals (Sweden)

    Baohua Shan

    2016-01-01

    Full Text Available For long-term monitoring of the midspan deflection of Songjiazhuang cloverleaf junction on 309 national roads in Zibo city, this paper proposes Zhang’s calibration-based DIC deflection monitoring method. CCD cameras are used to track the change of targets’ position, Zhang’s calibration algorithm is introduced to acquire the intrinsic and extrinsic parameters of CCD cameras, and the DIC method is combined with Zhang’s calibration algorithm to measure bridge deflection. The comparative test between Zhang’s calibration and scale calibration is conducted in lab, and experimental results indicate that the proposed method has higher precision. According to the deflection monitoring scheme, the deflection monitoring software for Songjiazhuang cloverleaf junction is developed by MATLAB, and a 4-channel CCD deflection monitoring system for Songjiazhuang cloverleaf junction is integrated in this paper. This deflection monitoring system includes functions such as image preview, simultaneous collection, camera calibration, deflection display, and data storage. In situ deflection curves show a consistent trend; this suggests that the proposed method is reliable and is suitable for the long-term monitoring of bridge deflection.

  6. Application of monitoring and targeting to energy management

    Energy Technology Data Exchange (ETDEWEB)

    Gotel, D G; Hale, D K

    1989-01-01

    This general guide has been prepared to show how monitoring and targeting can control energy use and improve the efficiency with which energy is used in different sectors of the national economy. It is based on the results of work carried out, under the Energy Efficiency Office Monitoring and Targeting Programme, on the development of practical energy management systems for use in manufacturing industry, commerce and the public sector. The principles of monitoring and targeting are described together with the steps which have to be taken to set up monitoring and targeting as an integral part of an existing management organization. Procedures are given for monitoring energy use, defining standards and targets, reporting results and reviewing progress. These procedures which have been developed and tested in working environments are illustrated with examples of their practical application. Finally, an account is given of the improvements of performance in the use of energy and the other benefits which can be gained through energy monitoring and targeting.

  7. Monitoring for materials fatigue in nuclear power plant

    International Nuclear Information System (INIS)

    Bartonicek, J.; Hienstorfer, W.

    1991-01-01

    The pressurizer surge line in unit 1 of the GKN nuclear power station belongs to the safety-relevant systems that have been monitored since the year 1987. The results of this in-service monitoring period show this component part experiences temperature fluctuations that have not been specified in the design documents of GKN 1. The in-service monitoring revealed both local and global temperature changes in the entire surge line, so that the resulting real stresses affecting the surge line can be derived and incorporated in a realistic fatigue analysis. (orig.) [de

  8. Continuous wireless pressure monitoring and mapping with ultra-small passive sensors for health monitoring and critical care.

    Science.gov (United States)

    Chen, Lisa Y; Tee, Benjamin C-K; Chortos, Alex L; Schwartz, Gregor; Tse, Victor; Lipomi, Darren J; Wong, H-S Philip; McConnell, Michael V; Bao, Zhenan

    2014-10-06

    Continuous monitoring of internal physiological parameters is essential for critical care patients, but currently can only be practically achieved via tethered solutions. Here we report a wireless, real-time pressure monitoring system with passive, flexible, millimetre-scale sensors, scaled down to unprecedented dimensions of 1 × 1 × 0.1 cubic millimeters. This level of dimensional scaling is enabled by novel sensor design and detection schemes, which overcome the operating frequency limits of traditional strategies and exhibit insensitivity to lossy tissue environments. We demonstrate the use of this system to capture human pulse waveforms wirelessly in real time as well as to monitor in vivo intracranial pressure continuously in proof-of-concept mice studies using sensors down to 2.5 × 2.5 × 0.1 cubic millimeters. We further introduce printable wireless sensor arrays and show their use in real-time spatial pressure mapping. Looking forward, this technology has broader applications in continuous wireless monitoring of multiple physiological parameters for biomedical research and patient care.

  9. Statistical analysis of dragline monitoring data

    Energy Technology Data Exchange (ETDEWEB)

    Mirabediny, H.; Baafi, E.Y. [University of Tehran, Tehran (Iran)

    1998-07-01

    Dragline monitoring systems are normally the best tool used to collect data on the machine performance and operational parameters of a dragline operation. This paper discusses results of a time study using data from a dragline monitoring system captured over a four month period. Statistical summaries of the time study in terms of average values, standard deviation and frequency distributions showed that the mode of operation and the geological conditions have a significant influence on the dragline performance parameters. 6 refs., 14 figs., 3 tabs.

  10. Monitoring and controlling the biogas process

    Energy Technology Data Exchange (ETDEWEB)

    Ahring, B K; Angelidaki, I [The Technical Univ. of Denmark, Dept. of Environmental Science and Engineering, Lyngby (Denmark)

    1997-08-01

    Many modern large-scale biogas plants have been constructed recently, increasing the demand for proper monitoring and control of these large reactor systems. For monitoring the biogas process, an easy to measure and reliable indicator is required, which reflects the metabolic state and the activity of the bacterial populations in the reactor. In this paper, we discuss existing indicators as well as indicators under development which can potentially be used to monitor the state of the biogas process in a reactor. Furthermore, data are presented from two large scale thermophilic biogas plants, subjected to temperature changes and where the concentration of volatile fatty acids was monitored. The results clearly demonstrated that significant changes in the concentration of the individual VFA occurred although the biogas production was not significantly changed. Especially the concentrations of butyrate, isobutyrate and isovalerate showed significant changes. Future improvements of process control could therefore be based on monitoring of the concentration of specific VFA`s together with information about the bacterial populations in the reactor. The last information could be supplied by the use of modern molecular techniques. (au) 51 refs.

  11. Air crew monitoring in Germany

    International Nuclear Information System (INIS)

    Stegemann, R.; Frasch, G.; Kammerer, L.

    2006-01-01

    Cosmic radiation at high altitudes, especially high energetic neutrons, significantly increases exposure to man. Pilots and flight attendants may receive annual effective doses comparable to doses received in occupations, in which ionising radiation is used or radioactive sources are handled. For this reason, the European Council Directive 96/29 EURATOM requires that air-crew members also be monitored for radiation protection. Flight personnel, receiving an effective dose from cosmic radiation of more than 1 mSv per year are subject to monitoring i.e. radiation exposure has to be assessed, limited and minimized. As the physical conditions causing cosmic radiation doses are well established, it is possible to calculate the expected radiation dose with sufficient accuracy. Several codes for this purpose are available. Since August 2003, the operators of airlines in Germany are obliged to assess the doses of their air crew personnel from cosmic radiation exposure and to minimise radiation exposure by means of appropriate work schedules, flight routes and flight profiles. Approx. 31 000 persons of 45 airlines are monitored by the German Radiation Protection Register. Gender, age and 3 different occupational categories are used to characterise different groups and their doses. The presentation will give an overview about the legislation and organisation of air crew monitoring in Germany and will show detailed statistical results from the first year of monitoring. (authors)

  12. Active Job Monitoring in Pilots

    Science.gov (United States)

    Kuehn, Eileen; Fischer, Max; Giffels, Manuel; Jung, Christopher; Petzold, Andreas

    2015-12-01

    Recent developments in high energy physics (HEP) including multi-core jobs and multi-core pilots require data centres to gain a deep understanding of the system to monitor, design, and upgrade computing clusters. Networking is a critical component. Especially the increased usage of data federations, for example in diskless computing centres or as a fallback solution, relies on WAN connectivity and availability. The specific demands of different experiments and communities, but also the need for identification of misbehaving batch jobs, requires an active monitoring. Existing monitoring tools are not capable of measuring fine-grained information at batch job level. This complicates network-aware scheduling and optimisations. In addition, pilots add another layer of abstraction. They behave like batch systems themselves by managing and executing payloads of jobs internally. The number of real jobs being executed is unknown, as the original batch system has no access to internal information about the scheduling process inside the pilots. Therefore, the comparability of jobs and pilots for predicting run-time behaviour or network performance cannot be ensured. Hence, identifying the actual payload is important. At the GridKa Tier 1 centre a specific tool is in use that allows the monitoring of network traffic information at batch job level. This contribution presents the current monitoring approach and discusses recent efforts and importance to identify pilots and their substructures inside the batch system. It will also show how to determine monitoring data of specific jobs from identified pilots. Finally, the approach is evaluated.

  13. On predicting monitoring system effectiveness

    Science.gov (United States)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  14. Configuration of risk monitor system by plant defense-in-depth risk monitor and reliability monitor

    International Nuclear Information System (INIS)

    Yoshikawa, Hidekazu; Lind Morten; Yang Ming; Hashim Muhammad; Zhang Zhijian

    2012-01-01

    A new method of risk monitor system of a nuclear power plant has been proposed from the aspect by what degree of safety functions incorporated in the plant system is maintained by multiple barriers of defense-in-depth (DiD). Wherein, the central idea is plant DiD risk monitor and reliability monitor derived from the five aspects of (1) design principle of nuclear safety based on DiD concept, (2) definition of risk and risk to be monitored, (3) severe accident phenomena as major risk, (4) scheme of risk ranking, and (5) dynamic risk display. In this paper, the overall frame of the proposed risk monitor system is summarized and the detailed discussion is made on major items such as definition of risk and risk ranking, anatomy of fault occurrence, two-layer configuration of risk monitor, how to configure individual elements of plant DiD risk monitor, and lastly how to apply for a PWR safety system. (author)

  15. Neuropharmacology of performance monitoring.

    Science.gov (United States)

    Jocham, Gerhard; Ullsperger, Markus

    2009-01-01

    Adaptive, goal-directed behavior requires that organisms evaluate their actions in terms of their outcomes. Neuroimaging studies show that unfavorable outcomes or situations with high level of conflict engage the posterior medial frontal cortex (pMFC). Recording of event-related potentials revealed that these situations are accompanied by a negative deflection, the so-called error-related negativity (ERN), which appears after an erroneous response or after negative feedback. Both activation of the pMFC and the ERN are thought to represent a signal that indicates the need for behavioral adjustment, and to recruit other brain regions that implement these adjustments. While many fMRI and EEG studies have shed light on the anatomical structures and the cognitive processes involved in performance monitoring, only very recently have researchers begun to investigate the underlying neurochemical mechanisms. Drawing on the putative involvement of dopamine (DA) neurons in coding a reward prediction error, an influential theory has ascribed a pivotal role to DA in performance monitoring. However, although important, DA is certainly not the only neuromodulator involved. Recent studies point to a role for serotonin, norepinephrine and GABA, but also for adenosine in performance monitoring. Here, we review the evidence for neurotransmitter effects on this function in humans. In this light, we critically discuss currently debated models of performance monitoring and potential alternatives.

  16. 1988 Monitoring Activities Review (MAR) of the environmental monitoring program

    International Nuclear Information System (INIS)

    1989-03-01

    The EGandG Idaho Environmental Monitoring (EM) Unit is responsible for coordinating and conducting environmental measurements of radioactive and hazardous contaminants around facilities operated by EGandG Idaho. The EM Unit has several broad program objectives, which include complying with regulatory standards and developing a basis for estimating future impacts of operations at EGandG Idaho facilities. To improve program planning and to provide bases for technical improvement of the monitoring program, the EGandG Environmental Monitoring organization has regularly used the Monitoring Activities Review (MAR) process since 1982. Each MAR is conducted by a committee of individuals selected for their experience in the various types of monitoring performed by the EM organization. Previous MAR studies have focused on procedures for all currently monitored media except biota. Biotic monitoring was initiated following the last MAR. This report focuses on all currently monitored media, and includes the first review of biotic monitoring. The review of biotic monitoring has been conducted at a level of detail consistent with initial MAR reports for other parts of the Waste Management Program Facilities Environmental Monitoring Program. The review of the biotic monitoring activities is presented in Section 5.5 of this report. 21 refs., 7 figs., 4 tabs

  17. Development and testing of a transparent membrane biofouling monitor

    KAUST Repository

    Dreszer, C.; Flemming, Hans Curt; Wexler, Adam D.; Zwijnenburg, Arie; Kruithof, Joop C.; Vrouwenvelder, Johannes S.

    2014-01-01

    A modified version of the membrane fouling simulator (MFS) was developed for assessment of (i) hydraulic biofilm resistance, (ii) performance parameters feed-channel pressure drop and transmembrane pressure drop, and (iii) in situ spatial visual and optical observations of the biofilm in the transparent monitor, e.g. using optical coherence tomography. The flow channel height equals the feed spacer thickness enabling operation with and without feed spacer. The effective membrane surface area was enlarged from 80 to 200 cm2 by increasing the monitor width compared to the standard MFS, resulting in larger biomass amounts for analysis. By use of a microfiltration membrane (pore size 0.05 μm) in the monitor salt concentration polarization is avoided, allowing operation at low pressures enabling accurate measurement of the intrinsic hydraulic biofilm resistance. Validation tests on e.g. hydrodynamic behavior, flow field distribution, and reproducibility showed that the small-sized monitor was a representative tool for membranes used in practice under the same operating conditions, such as spiral-wound nanofiltration and reverse osmosis membranes. Monitor studies with and without feed spacer use at a flux of 20 L m-2 h-1 and a cross-flow velocity of 0.1 m s-1 clearly showed the suitability of the monitor to determine hydraulic biofilm resistance and for controlled biofouling studies. © 2013 Balaban Desalination Publications. All rights reserved.

  18. Development and testing of a transparent membrane biofouling monitor

    KAUST Repository

    Dreszer, C.

    2014-01-02

    A modified version of the membrane fouling simulator (MFS) was developed for assessment of (i) hydraulic biofilm resistance, (ii) performance parameters feed-channel pressure drop and transmembrane pressure drop, and (iii) in situ spatial visual and optical observations of the biofilm in the transparent monitor, e.g. using optical coherence tomography. The flow channel height equals the feed spacer thickness enabling operation with and without feed spacer. The effective membrane surface area was enlarged from 80 to 200 cm2 by increasing the monitor width compared to the standard MFS, resulting in larger biomass amounts for analysis. By use of a microfiltration membrane (pore size 0.05 μm) in the monitor salt concentration polarization is avoided, allowing operation at low pressures enabling accurate measurement of the intrinsic hydraulic biofilm resistance. Validation tests on e.g. hydrodynamic behavior, flow field distribution, and reproducibility showed that the small-sized monitor was a representative tool for membranes used in practice under the same operating conditions, such as spiral-wound nanofiltration and reverse osmosis membranes. Monitor studies with and without feed spacer use at a flux of 20 L m-2 h-1 and a cross-flow velocity of 0.1 m s-1 clearly showed the suitability of the monitor to determine hydraulic biofilm resistance and for controlled biofouling studies. © 2013 Balaban Desalination Publications. All rights reserved.

  19. [Design and implementation of real-time continuous glucose monitoring instrument].

    Science.gov (United States)

    Huang, Yonghong; Liu, Hongying; Tian, Senfu; Jia, Ziru; Wang, Zi; Pi, Xitian

    2017-12-01

    Real-time continuous glucose monitoring can help diabetics to control blood sugar levels within the normal range. However, in the process of practical monitoring, the output of real-time continuous glucose monitoring system is susceptible to glucose sensor and environment noise, which will influence the measurement accuracy of the system. Aiming at this problem, a dual-calibration algorithm for the moving-window double-layer filtering algorithm combined with real-time self-compensation calibration algorithm is proposed in this paper, which can realize the signal drift compensation for current data. And a real-time continuous glucose monitoring instrument based on this study was designed. This real-time continuous glucose monitoring instrument consisted of an adjustable excitation voltage module, a current-voltage converter module, a microprocessor and a wireless transceiver module. For portability, the size of the device was only 40 mm × 30 mm × 5 mm and its weight was only 30 g. In addition, a communication command code algorithm was designed to ensure the security and integrity of data transmission in this study. Results of experiments in vitro showed that current detection of the device worked effectively. A 5-hour monitoring of blood glucose level in vivo showed that the device could continuously monitor blood glucose in real time. The relative error of monitoring results of the designed device ranged from 2.22% to 7.17% when comparing to a portable blood meter.

  20. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Newcomer, D.R.; Thornton, E.C.; Hartman, M.J.; Dresel, P.E.

    1999-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954 the Resource Conservation and Recovery Act of 1976 the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The US Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/frequency matrix for the entire site. The objectives of monitoring fall into three general categories plume and trend tracking, treatment/storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  1. Facility effluent monitoring plan for 242-A evaporator facility

    International Nuclear Information System (INIS)

    Crummel, G.M.; Gustavson, R.D.

    1995-02-01

    A facility effluent monitoring plan is required by the U.S. Department of Energy in DOE Order 5400.1 for any operations that involve hazardous materials and radioactive substances that could affect employee or public safety or the environment. A facility effluent monitoring plan determination was performed during Calendar Year 1991 and the evaluation showed the need for a facility effluent monitoring plan. This document is prepared using the specific guidelines identified in A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438-1. This facility effluent monitoring plan assesses effluent monitoring systems and evaluates whether they are adequate to ensure the public health and safety as specified in applicable federal, state, and local requirements. This facility effluent monitoring plan shall ensure long-range integrity of the effluent monitoring systems by requiring an update whenever a new process or operation introduces new hazardous materials or significant radioactive materials. This document must be reviewed annually even if there are no operational changes, and it must be updated, as a minimum, every three years

  2. Soil monitoring as a part of environment monitoring in Slovakia

    International Nuclear Information System (INIS)

    Kobza, J.

    1997-01-01

    In frame of Soil monitoring system it is going about a lot of methods in advance as follows: methods of soil monitoring sites selection and soil monitoring network construction, as well; methods of soil survey and soil sampling; analytical methods (indicating of chemical, agrochemical and physical properties); soil database and methods of evaluation and interpretation of measured results. The monitoring network was constructed on the base of ecological principles - including the monitoring of all soil types and subtypes, various climatic and emission regions as well as relatively clean regions, lowland and highland. Soil monitoring network in forest land is regular (8 x 8 km) with regard to International monitoring system in Forestry. The soil monitoring network in Slovakia consist of 650 monitoring sites (312 sites in farming land and 338 sites in forest land). In addition soil monitoring network includes also 21 monitoring sites. All monitoring sites are geodesically located and reported on the map at a scale of 1:5000. There are the methods concerning the important soil parameters indication with regard to main soil degradation processes a s follows: soil contamination (heavy metals and organic contaminants); soil acidification; soil salinity; soil erosion (deluometrically by the Cs-137 and remote sensing methods); soil compaction; soil fertility and protection. Analytical control system was elaborated according to Good Laboratory Practice. Evaluation of soil monitoring network results is not simple because it depends on various monitored parameters, on aim of evaluation as well as on the scale of landscape which is object for evaluation. There are used the modern statistical methods in monitoring system which can be: universal; disjunctive; simulated. Used statistical methods are significant for interpretation of measured results as follows: trends in landscape; anisotropy; comparison. The evaluation and interpretation way is very significant with regard not

  3. Análise da variabilidade da freqüência cardíaca em pacientes hipertensos, antes e depois do tratamento com inibidores da enzima conversora da angiotensina II Analysis of heart rate variability in hypertensive patients before and after treatment with angiotensin II-converting enzyme inhibitors

    Directory of Open Access Journals (Sweden)

    Antônio da Silva Menezes Júnior

    2004-08-01

    Full Text Available OBJETIVO: Comparar a variabilidade de freqüência cardíaca em indivíduos normotensos e hipertensos e observar o comportamento do sistema nervoso autônomo após terapia com inibidores da enzima conversora de angiotensina II. MÉTODO: Estudados 286 pacientes com diagnóstico de hipertensão arterial, pela 1ª vez, e divididos em 4 grupos, conforme a pressão arterial diastólica (PAD: grupo A - PAD110 mmHg. Os pacientes do grupo A (normais e do grupo C (HA moderada, somando 110 e 79 pacientes, respectivamente, submeteram-se ao Holter-ECG 24h com análise de variabilidade de freqüência cardíaca no domínio do tempo (DT e no domínio da freqüência (DF. O grupo C foi tratado com inibidores da ECA durante 3 meses, e após esse período novamente avaliado com Holter-ECG 24h e variabilidade da freqüência cardíaca, e os valores comparados com os normotensos. RESULTADOS: Os parâmetros SDNN, PNN50 (DT e o espectro LF (DF foram significativamente diferentes para os dois grupos, com valores notadamente diminuídos em hipertensos (pOBJECTIVE: To compare heart rate variability in normotensive and hypertensive individuals and to observe the behavior of the autonomic nervous system after treatment with angiotensin II-converting enzyme inhibitors. METHOD: The study comprised 286 patients diagnosed with arterial hypertension (AH for the first time and divided into 4 groups according to diastolic blood pressure (DBP levels: group A - DBP110 mmHg. Group A (110 healthy individuals and group C (79 patients with moderate AH underwent 24-hour Holter-ECG with analysis of heart rate variability in time domain (TD and frequency domain (FD. The group C patients were treated with ACE inhibitors for 3 months, and, after this period, they underwent a new 24-hour Holter-ECG study for assessing heart rate variability, the values being compared with those of normotensive individuals. RESULTS: The SDNN and PNN50 parameters (TD, and the LF spectrum (FD were

  4. The Brazilian external individual monitoring scenario

    International Nuclear Information System (INIS)

    Mauricio, Claudia L.P.; Silva, Claudio R. da; Cunha, Paulo G. da

    2015-01-01

    In order to improve radiation protection it is necessary to have knowledge of the occupational radiation dose levels in all radiation facilities. This information comes from individual monitoring services, which are responsible for measuring and providing information about workers' radiation exposure. In 1981, the Comissao Nacional de Energia Nuclear (CNEN) of Brazil starts to develop a comprehensive system for regulation and storage of occupational radiation dose. This paper starts with an overview of the evolution of the Brazilian authorization and data storage system for external individual monitoring. It starts with a rule for authorization of all Brazilian photon individual monitoring services and the obligation for them to send the measured dose to CNEN. Up to now there is no regulation for neutron individual monitoring. The aim of this paper is to present the current scenario of the Brazilian external monitoring system, reinforcing its importance and remaining problems. The number of monitored workers greatly increases every year, having surpassed 150,000 people monitored. The stored data show that the mean annual occupational external dose is decreasing from 2.4 mSv in 1987 to about 0.6 mSv, in 2012, but there is still some not realistic very high dose measured (higher than 100 mSv), without investigation. About 80% of the annual dose values are lower than the monthly register level. As expected, the higher real photon doses are found in Nuclear Medicine, Industrial Radiology and Interventional Radiology. All recorded annual neutron dose values are lower than 20 mSv. (author)

  5. Integrated Monitoring Plan for the Hanford Groundwater Monitoring Project

    International Nuclear Information System (INIS)

    Hartman, Mary J.; Dresel, P. Evan; Lindberg, Jon W.; Newcomer, Darrell R.; Thornton, Edward C.

    2000-01-01

    Groundwater is monitored at the Hanford Site to fulfill a variety of state and federal regulations, including the Atomic Energy Act of 1954; the Resource Conservation and Recovery Act of 1976; the Comprehensive Environmental Response, Compensation, and Liability Act of 1980; and Washington Administrative Code. Separate monitoring plans are prepared for various requirements, but sampling is coordinated and data are shared among users to avoid duplication of effort. The U.S. Department of Energy manages these activities through the Hanford Groundwater Monitoring Project. This document is an integrated monitoring plan for the groundwater project. It documents well and constituent lists for monitoring required by the Atomic Energy Act of 1954 and its implementing orders; includes other, established monitoring plans by reference; and appends a master well/constituent/ frequency matrix for the entire site. The objectives of monitoring fall into three general categories: plume and trend tracking, treatment/ storage/disposal unit monitoring, and remediation performance monitoring. Criteria for selecting Atomic Energy Act of 1954 monitoring networks include locations of wells in relation to known plumes or contaminant sources, well depth and construction, historical data, proximity to the Columbia River, water supplies, or other areas of special interest, and well use for other programs. Constituent lists were chosen based on known plumes and waste histories, historical groundwater data, and, in some cases, statistical modeling. Sampling frequencies were based on regulatory requirements, variability of historical data, and proximity to key areas. For sitewide plumes, most wells are sampled every 3 years. Wells monitoring specific waste sites or in areas of high variability will be sampled more frequently

  6. Studies of the action of chemical agents on the heart. Annual report, February 1985-February 1986

    Energy Technology Data Exchange (ETDEWEB)

    Hassler, G.R.; Moutvic, R.R.

    1986-03-01

    This report describes initial studies to determine the subchronic effect of Soman and Sarin, on the electrical, mechanical, and neurochemical properties of the heart. Two different animal models are under development. The electrophysiologic and hemodynamic aspects of survival doses of chemical agent are begin studied in the dog. Two chronically instrumented dog models have been developed. The first is a hemodynamic dog model in which long-term measurements of left and right heart pressures, aortic flow, coronary flow as well as epicardial electrocardiograms, are monitored. The animals will be monitored at baseline and for one month following exposure in survival of a chemical-warfare-agent insult. These animals are stressed via treadmill exercise. The electrophysiology dog model consists of chronically implanted electrodes for performance of repetitive ventricular response stimulation, His bundle recording, and ECG analysis. Measurements are made prior to, and for one month following, exposure to survivable doses of CW agent. This dog model is further probed by sequential administration of various pharmacologic agents designed to study the autonomic status of the heart. All dogs and a limited number of the guinea pigs will be continuously monitored for occurrence of arrhythmic events utilizing Holter monitoring technology. The guinea pig neurochemical studies will include acetylcholines, choline acetyltransferase activity, QNB binding, choline uptake, norepinephrine levels and turnover, and norepinephrine uptake experiments.

  7. Pig herd monitoring and undesirable tripping and stepping prevention

    DEFF Research Database (Denmark)

    Gronskyte, Ruta; Clemmensen, Line Katrine Harder; Hviid, Marchen Sonja

    2015-01-01

    Humane handling and slaughter of livestock are of major concern in modern societies. Monitoring animal wellbeing in slaughterhouses is critical in preventing unnecessary stress and physical damage to livestock, which can also affect the meat quality. The goal of this study is to monitor pig herds...... at the slaughterhouse and identify undesirable events such as pigs tripping or stepping on each other. In this paper, we monitor pig behavior in color videos recorded during unloading from transportation trucks. We monitor the movement of a pig herd where the pigs enter and leave a surveyed area. The method is based...... on optical flow, which is not well explored for monitoring all types of animals, but is the method of choice for human crowd monitoring. We recommend using modified angular histograms to summarize the optical flow vectors. We show that the classification rate based on support vector machines is 93% of all...

  8. Echocardiographic and clinical findings in patients with Fabry disease during long-term enzyme replacement therapy

    DEFF Research Database (Denmark)

    Madsen, Christoffer Valdorff; Bundgaard, Henning; Rasmussen, Åse Krogh

    2017-01-01

    from baseline to follow-up; 30 mm [15-53] vs. 25 mm [3-44], p vs. 1520 mm·ms [550-5740], p within the non-ERT group. During follow-up, cardiac symptoms and use of cardiovascular procedures and -medication increased...... significantly in the ERT group, whereas no differences were observed within the non-ERT group. DISCUSSION: We raise concerns regarding the efficacy and benefit of ERT on cardiac involvement in Fabry disease and stress the need for further research....... and Holter-monitoring. RESULTS: We included 66 patients; 47 patients (27 women) received ERT (ERT group) and 19 patients (15 women) did not (non-ERT group). The groups were followed for a median of 8 [0-12] years and 6 [0-13] years, respectively. Comparison between ERT and non-ERT receiving patients by left...

  9. Autonomic dysfunction and impaired cerebral autoregulation in cirrhosis

    DEFF Research Database (Denmark)

    Frøkjaer, Vibe G; Strauss, Gitte I; Mehlsen, Jesper

    2006-01-01

    Cerebral blood flow autoregulation is lost in patients with severe liver cirrhosis. The cause of this is unknown. We determined whether autonomic dysfunction was related to impaired cerebral autoregulation in patients with cirrhosis. Fourteen patients with liver cirrhosis and 11 healthy volunteers...... were recruited. Autonomic function was assessed in response to deep breathing, head-up tilt and during 24-h Holter monitoring. Cerebral autoregulation was assessed by determining the change in mean cerebral blood flow velocity (MCAVm, transcranial Doppler) during an increase in blood pressure induced...... by norepinephrine infusion (NE). The severity of liver disease was assessed using the Child-Pugh scale (class A, mild; class B, moderate; class C, severe liver dysfunction).NE increased blood pressure similarly in the controls (27 (24-32) mmHg) and patients with the most severe liver cirrhosis (Child-Pugh C, 31 (26...

  10. Relation between emotional distress and heart rate variability in patients with an implantable cardioverter-defibrillator

    DEFF Research Database (Denmark)

    Hoogwegt, Madelein T; Pedersen, Susanne S.; Theuns, Dominic A M J

    2014-01-01

    We investigated the relationship between Type D personality, depression, and anxiety, and heart rate variability (HRV) in 64 patients with an implantable cardioverter-defibrillator (ICD). HRV was obtained via 24-h Holter monitoring, and 24-h, 30-min daytime rest and 30-min nighttime sleep HRV were...... analyzed. In adjusted analyses, significant associations (standard deviation of normal-to-normal [NN] intervals [SDNN]: p = .043; standard deviation of NN intervals over 5-min periods [SDANN]: p = .010) and a trend (HRV triangular index: p = .09) were found for Type D personality, and trends were found...... = .043). A Benjamini-Hochberg correction for multiple testing led to reduction of the number of significant relationships, but there was still support for lower autonomic control patients with Type D personality and depression. Future research with larger sample sizes is warranted....

  11. Show-Bix &

    DEFF Research Database (Denmark)

    2014-01-01

    The anti-reenactment 'Show-Bix &' consists of 5 dias projectors, a dial phone, quintophonic sound, and interactive elements. A responsive interface will enable the Dias projectors to show copies of original dias slides from the Show-Bix piece ”March på Stedet”, 265 images in total. The copies are...

  12. Comparative evaluation of online oil and gas monitor; Avaliacao de monitores de teor de oleo e graxa em linha

    Energy Technology Data Exchange (ETDEWEB)

    Louvisse, Ana Maria Travalloni; Pereira Junior, Oswaldo de Aquino; Jesus, Rafael Ferreira de; Santos, Lino Antonio Duarte dos; Lopes, Humberto Eustaquio [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2004-07-01

    Petroleum is predominantly recovered in form of water in oil emulsions, which are stabilised by petroleum resins and asphaltenes, the colloidal disperse components of crude oil. The water phase, separated during the production process, consists of a dilute oil in water emulsion, commonly called produced water.There are a wide variety of methods for determination of oil in produced water that are commercially based on a number of technique. On line continuously monitoring shall be particularly useful in providing information to assist in optimising the separation process and also to attend the environmental legislation for discharge the produced water. There are a wide variety of on line oil in water monitors that are commercially available based on a number of technique. In this paper, a comparative evaluation was made between some methods of on line oil in water detecting. These are light scattering and ultraviolet fluorescence technique. A brief description of the optical methods will be discussed and some of associated problems and limitation are pointed. The work was done in a specific experimental set up that allows the simultaneous pumping of crude oil and water through a calibrated restriction in a pipe has been used. A permanent pressure drop induced by the restriction leads to the dispersion of the oil droplets in the water phase. The monitors based on light scattering technique tested show good agreement between monitor reading and the oil dispersion used. Otherwise for ultraviolet fluorescence based monitors show a significant effect of the variation of oil type. (author)

  13. Using widgets to monitor the LHC experiments

    International Nuclear Information System (INIS)

    Caballero, I González; Sarkar, S

    2011-01-01

    The complexity of the LHC experiments requires monitoring systems to verify the correct functioning of different sub-systems and to allow operators to quickly spot problems and issues that may cause loss of information and data. Due to the distributed nature of the collaborations and the different technologies involved, the information data that need to be correlated is usually spread over several databases, web pages and monitoring systems. On the other hand, although the complete set of monitorable aspects is known and fixed, the subset that each person needs to monitor is often different for each individual. Therefore, building a unique monitoring tool that suits every single collaborator becomes close to impossible. A modular approach with a set of customizable widgets, small autonomous portions of HTML and JavaScript, that can be aggregated to form private or public monitoring web pages can be a scalable and robust solution, where the information can be provided by a simple and thin set of web services. Among the different widget development toolkits available today, we have chosen the open project UWA (Unified Widget API) because of its portability to the most popular widget platforms (including iGoogle, Netvibes and Apple Dashboard). As an example, we show how this technology is currently being used to monitor parts of the CMS Computing project.

  14. Continuous EEG-SEP monitoring in severe brain injury.

    Science.gov (United States)

    Amantini, A; Fossi, S; Grippo, A; Innocenti, P; Amadori, A; Bucciardini, L; Cossu, C; Nardini, C; Scarpelli, S; Roma, V; Pinto, F

    2009-04-01

    To monitor acute brain injury in the neurological intensive care unit (NICU), we used EEG and somatosensory evoked potentials (SEP) in combination to achieve more accuracy in detecting brain function deterioration. Sixty-eight patients (head trauma and intracranial hemorrhage; GCSSEP and intracranial pressure monitoring (ICP). Fifty-five patients were considered "stable" or improving, considering the GCS and CT scan: in this group, SEP didn't show significant changes. Thirteen patients showed neurological deteriorations and, in all patients, cortical SEP showed significant alterations (amplitude decrease>50% often till complete disappearance). SEP deterioration anticipated ICP increase in 30%, was contemporary in 38%, and followed ICP increase in 23%. Considering SEP and ICP in relation to clinical course, all patients but one with ICP less than 20 mmHg were stable, while the three patients with ICP greater than 40 mmHg all died. Among the 26 patients with ICP of 20-40 mmHg, 17 were stable, while nine showed clinical and neurophysiological deterioration. Thus, there is a range of ICP values (20-40 mmHg) were ICP is scarcely indicative of clinical deterioration, rather it is the SEP changes that identify brain function deterioration. Therefore, SEP have a twofold interest with respect to ICP: their changes can precede an ICP increase and they can constitute a complementary tool to interpret ICP trends. It has been very important to associate SEP and EEG: about 60% of our patients were deeply sedated and, because of their relative insensitivity to anesthetics, only SEP allowed us to monitor brain damage evolution when EEG was scarcely valuable. We observed 3% of nonconvulsive status epilepticus compared to 18% of neurological deterioration. If the aim of neurophysiological monitoring is to "detect and protect", it may not be limited to detecting seizures, rather it should be able to identify brain deterioration, so we propose the combined monitoring of EEG with SEP.

  15. Thermal performance monitoring and optimisation

    International Nuclear Information System (INIS)

    Sunde, Svein; Berg; Oeyvind

    1998-01-01

    Monitoring of the thermal efficiency of nuclear power plants is expected to become increasingly important as energy-market liberalisation exposes plants to increasing availability requirements and fiercer competition. The general goal in thermal performance monitoring is straightforward: to maximise the ratio of profit to cost under the constraints of safe operation. One may perceive this goal to be pursued in two ways, one oriented towards fault detection and cost-optimal predictive maintenance, and another determined at optimising target values of parameters in response to any component degradation detected, changes in ambient conditions, or the like. Annual savings associated with effective thermal-performance monitoring are expected to be in the order of $ 100 000 for power plants of representative size. A literature review shows that a number of computer systems for thermal-performance monitoring exists, either as prototypes or commercially available. The characteristics and needs of power plants may vary widely, however, and decisions concerning the exact scope, content and configuration of a thermal-performance monitor may well follow a heuristic approach. Furthermore, re-use of existing software modules may be desirable. Therefore, we suggest here the design of a flexible workbench for easy assembly of an experimental thermal-performance monitor at the Halden Project. The suggested design draws heavily on our extended experience in implementing control-room systems featured by assets like high levels of customisation, flexibility in configuration and modularity in structure, and on a number of relevant adjoining activities. The design includes a multi-computer communication system and a graphical user's interface, and aims at a system adaptable to any combination of in-house or end user's modules, as well as commercially available software. (author)

  16. Work place monitoring in accelerator facilities using thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Ribeiro, M.S.; Sanches, M.P.; Osima, A.M.; Rodriguez, D.L.; Carvalho, R.N.; Somessari, R.N.

    1998-01-01

    The increase in the use of large amounts of energy and large particles accelerators in development or in industrial processes for the reticulation, polymerization and sterilization of cables and wires allowed to discover and monitor work places in facilities having particle accelerators at the Institute of Energy and Nuclear Inquiries Comissao National de Energy Nuclear. Measures previously taken by technicians in routine monitoring, show that radiation doses found in the beams tube and at the door of the accelerator area is high enough to require routine programs to monitor work places at the installation. That is why, fifteen thermoluminescent dosimeters (TLD) where placed in different points of the facility where doses must be measured along a three month period and at the same time readings must be taken from control dosimeters kept within a shielded container. The monitor had a small double layer with three pellets of TLD CaSO4 Dy inside of a route carrier adopted in routine workers dosimetry usually. Outcomes show that the radiological protection program must be implemented to ameliorate and guarantee safety procedures

  17. Ambulatory Blood Pressure Monitoring in Clinical Practice: A Review

    Science.gov (United States)

    Viera, Anthony J.; Shimbo, Daichi

    2016-01-01

    Ambulatory blood pressure monitoring offers the ability to collect blood pressure readings several times an hour across a 24-hour period. Ambulatory blood pressure monitoring facilitates the identification of white-coat hypertension, the phenomenon whereby certain individuals who are not on antihypertensive medication show elevated blood pressure in a clinical setting but show non-elevated blood pressure averages when assessed by ambulatory blood pressure monitoring. Additionally, readings can be segmented into time windows of particular interest, e.g., mean daytime and nighttime values. During sleep, blood pressure typically decreases, or dips, such that mean sleep blood pressure is lower than mean awake blood pressure. A non-dipping pattern and nocturnal hypertension are strongly associated with increased cardiovascular morbidity and mortality. Approximately 70% of individuals dip ≥10% at night, while 30% have non-dipping patterns, when blood pressure remains similar to daytime average, or occasionally rises above daytime average. The various blood pressure categorizations afforded by ambulatory blood pressure monitoring are valuable for clinical management of high blood pressure since they increase accuracy for diagnosis and the prediction of cardiovascular risk. PMID:25107387

  18. Intracranial pressure monitoring in severe blunt head trauma: does the type of monitoring device matter?

    Science.gov (United States)

    Aiolfi, Alberto; Khor, Desmond; Cho, Jayun; Benjamin, Elizabeth; Inaba, Kenji; Demetriades, Demetrios

    2018-03-01

    OBJECTIVE Intracranial pressure (ICP) monitoring has become the standard of care in the management of severe head trauma. Intraventricular devices (IVDs) and intraparenchymal devices (IPDs) are the 2 most commonly used techniques for ICP monitoring. Despite the widespread use of these devices, very few studies have investigated the effect of device type on outcomes. The purpose of the present study was to compare outcomes between 2 types of ICP monitoring devices in patients with isolated severe blunt head trauma. METHODS This retrospective observational study was based on the American College of Surgeons Trauma Quality Improvement Program database, which was searched for all patients with isolated severe blunt head injury who had an ICP monitor placed in the 2-year period from 2013 to 2014. Extracted variables included demographics, comorbidities, mechanisms of injury, head injury specifics (epidural, subdural, subarachnoid, intracranial hemorrhage, and diffuse axonal injury), Abbreviated Injury Scale (AIS) score for each body area, Injury Severity Score (ISS), vital signs in the emergency department, and craniectomy. Outcomes included 30-day mortality, complications, number of ventilation days, intensive care unit and hospital lengths of stay, and functional independence. RESULTS During the study period, 105,721 patients had isolated severe traumatic brain injury (head AIS score ≥ 3). Overall, an ICP monitoring device was placed in 2562 patients (2.4%): 1358 (53%) had an IVD and 1204 (47%) had an IPD. The severity of the head AIS score did not affect the type of ICP monitoring selected. There was no difference in the median ISS; ISS > 15; head AIS Score 3, 4, or 5; or the need for craniectomy between the 2 device groups. Unadjusted 30-day mortality was significantly higher in the group with IVDs (29% vs 25.5%, p = 0.046); however, stepwise logistic regression analysis showed that the type of ICP monitoring was not an independent risk factor for death

  19. Remote monitoring demonstration

    International Nuclear Information System (INIS)

    Caskey, Susan; Olsen, John

    2006-01-01

    The recently upgraded remote monitoring system at the Joyo Experimental Reactor uses a DCM-14 camera module and GEMINI software. The final data is compatible both with the IAEA-approved GARS review software and the ALIS software that was used for this demonstration. Features of the remote monitoring upgrade emphasized compatibility with IAEA practice. This presentation gives particular attention to the selection process for meeting network security considerations at the O'arai site. The Joyo system is different from the NNCA's ACPF system, in that it emphasizes use of IAEA standard camera technology and data acquisition and transmission software. In the demonstration itself, a temporary virtual private network (VPN) between the meeting room and the server at Sandia in Albuquerque allowed attendees to observe data stored from routine transmissions from the Joyo Fresh Fuel Storage to Sandia. Image files from a fuel movement earlier in the month showed Joyo workers and IAEA inspectors carrying out a transfer. (author)

  20. Recurrent unexplained palpitations (RUP) study comparison of implantable loop recorder versus conventional diagnostic strategy.

    Science.gov (United States)

    Giada, Franco; Gulizia, Michele; Francese, Maura; Croci, Francesco; Santangelo, Lucio; Santomauro, Maurizio; Occhetta, Eraldo; Menozzi, Carlo; Raviele, Antonio

    2007-05-15

    The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations. In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis. We studied 50 patients with infrequent (1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) (n = 24) or to ILR implantation with 1-year monitoring (n = 26). Hospital costs of the 2 strategies were calculated. A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p < 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group (euro 3,056 +/- euro 363 vs. euro 6,768 +/- euro 6,672, p = 0.012). In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy.

  1. Home-based mobile cardio-pulmonary rehabilitation consultant system.

    Science.gov (United States)

    Lee, Hsu-En; Wang, Wen-Chih; Lu, Shao-Wei; Wu, Bo-Yuan; Ko, Li-Wei

    2011-01-01

    Cardiovascular diseases are the most popular cause of death in the world recently. For postoperatives, cardiac rehabilitation is still asked to maintain at home (phase II) to improve cardiac function. However, only one third of outpatients do the exercise regularly, reflecting the difficulty for home-based healthcare: lacking of monitoring and motivation. Hence, a cardio-pulmonary rehabilitation system was proposed in this research to improve rehabilitation efficiency for better prognosis. The proposed system was built on mobile phone and receiving electrocardiograph (ECG) signal from a wireless ECG holter via Bluetooth connection. Apart from heart rate (HR) monitor, an ECG derived respiration (EDR) technique is also included to provide respiration rate (RR). Both HR and RR are the most important vital signs during exercise but only used one physiological signal recorder in this system. In clinical test, there were 15 subjects affording Bruce Task (treadmill) to simulate rehabilitation procedure. Correlation between this system and commercial product (Custo-Med) was up to 98% in HR and 81% in RR. Considering the prevention of sudden heart attack, an arrhythmia detection expert system and healthcare server at the backend were also integrated to this system for comprehensive cardio-pulmonary monitoring whenever and wherever doing the exercise.

  2. Electrocardiographic and Blood Pressure Alterations During Electroconvulsive Therapy in Young Adults

    Directory of Open Access Journals (Sweden)

    Rumi Demetrio Ortega

    2002-01-01

    Full Text Available OBJECTIVE - To study cardiovascular alterations in young patients with no apparent organic disease who underwent electroconvulsive therapy. METHODS - The study comprised 47 healthy patients (22 males and 25 females with a mean age of 30.3 years, who underwent electroconvulsive therapy. Ambulatory blood pressure monitoring and continuous electrocardiographic monitoring (Holter monitor were performed during 24 hours. Blood pressure and heart rate were assessed 4 hours prior to electric shock administration, during electric shock administration, and 3 hours after electric shock administration. Arrhythmias and alterations in the ST segment in 24 hours were recorded. RESULTS - On electroconvulsive therapy, a significant increase in blood pressure and heart rate was observed and the measurements returned to basal values after 25 minutes. Three females had tracings with depression of the ST segment suggesting myocardial ischemia prior to and after electroconvulsive therapy. Coronary angiography was normal. No severe cardiac arrhythmias were diagnosed. CONCLUSION - 1 Electroconvulsive therapy is a safe therapeutic modality in psychiatry; 2 it causes a significant increase in blood pressure and heart rate; 3 it may be associated with myocardial ischemia in the absence of coronary obstructive disease; 4 electroconvulsive therapy was not associated with the occurrence of severe cardiac arrhythmias.

  3. Towards innovative roadside monitoring

    Science.gov (United States)

    Ojha, G.; Appel, E.; Magiera, T.

    2012-04-01

    Soil contamination along roadsides is an important factor of anthropogenic point source pollution. Climatic and traffic-specific factors influence the amount and characteristics of pollution emitted and deposited in the roadside soil. In our present study we focus on monitoring typical traffic pollutants (heavy metals HM, platinum group elements, polycyclic hydrocarbons PAH), and investigate the use of magnetic parameters, especially magnetic susceptibility (MS) as proxy. Monitoring plots were installed along roadside in areas with different climatic conditions and different traffic-specific activities (traffic density and speed, vehicle types, abrasion of tires, brake linings, petrol/diesel compounds and road maintenance). For monitoring we removed 10-15 cm of top soil at 1 m distance from the roadside edge and placed 30 plastic boxes there filled with clean quartz sand, to be sampled after regular intervals within two years. Preliminary data from the first year of monitoring are presented. Magnetic results revealed that a coarse grained magnetite-like phase is responsible for the enhancement of magnetic concentration. The mass-specific MS and concentration of pollutants (HM, PAH) all show a significant increase with time, however, there are obviously also seasonal and site-dependent effects which lead to more stable values over several months or even some decrease in the upper few cm due to migration into depth. Source identification indicates that the accumulated PAHs are primarily emissions from traffic. In order to be able to discriminate in between different kinds of transport and deposition (surface run off from the road and neighbouring soil material, splash water, air transport), we additionally established pillars at the roadside with clean quartz sampling boxes at different heights (surface, 0.5 m, 2 m). As a first surprising result we observed that the increase in the boxes at surface is not necessarily higher than at 0.5 m height. The results from our

  4. An Electrical Energy Consumption Monitoring and Forecasting System

    Directory of Open Access Journals (Sweden)

    J. L. Rojas-Renteria

    2016-10-01

    Full Text Available Electricity consumption is currently an issue of great interest for power companies that need an as much as accurate profile for controlling the installed systems but also for designing future expansions and alterations. Detailed monitoring has proved to be valuable for both power companies and consumers. Further, as smart grid technology is bound to result to increasingly flexible rates, an accurate forecast is bound to prove valuable in the future. In this paper, a monitoring and forecasting system is investigated. The monitoring system was installed in an actual building and the recordings were used to design and evaluate the forecasting system, based on an artificial neural network. Results show that the system can provide detailed monitoring and also an accurate forecast for a building’s consumption.

  5. Woking Park phosphoric acid fuel cell CHP monitoring

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-09-15

    A phosphoric acid fuel (PC25) delivering up to 200kw of electrical power and commensurate heat was installed in Woking Park UK in late 2006 and has been monitored over a period of one year. The system supplies electric power to a leisure centre and swimming pool via a private wires network. This report gives details of the monitoring and shows a schematic of the system, data on electrical and thermal efficiencies, stack voltage variations and gaseous emissions. Extended monitoring is now taking place to provide a complete picture of the economics and operation of the fuel cell in the developing combined heat and power unit and private wires system. The contractor is Advantica of Loughborough and detailed results of the monitoring are available on the DTI website.

  6. Pollen and spore monitoring in the world.

    Science.gov (United States)

    Buters, J T M; Antunes, C; Galveias, A; Bergmann, K C; Thibaudon, M; Galán, C; Schmidt-Weber, C; Oteros, J

    2018-01-01

    Ambient air quality monitoring is a governmental duty that is widely carried out in order to detect non-biological ("chemical") components in ambient air, such as particles of monitoring networks are publicly funded and air quality data are open to the public. The situation for biological particles that have detrimental effects on health, as is the case of pollen and fungal spores, is however very different. Most pollen and spore monitoring networks are not publicly funded and data are not freely available. The information regarding which biological particle is being monitored, where and by whom, is consequently often not known, even by aerobiologists themselves. This is a considerable problem, as local pollen data are an important tool for the prevention of allergic symptoms. The aim of this study was to review pollen monitoring stations throughout the world and to create an interactive visualization of their distribution. The method employed to collect information was based on: (a) a review of the recent and historical bibliography related to pollen and fungal spore monitoring, and (b) personal surveys of the managers of national and regional monitoring networks. The interactive application was developed using the R programming language. We have created an inventory of the active pollen and spore monitoring stations in the world. There are at least 879 active pollen monitoring stations in the world, most of which are in Europe (> 500). The prevalent monitoring method is based on the Hirst principle (> 600 stations). The inventory is visualised as an interactive and on-line map. It can be searched, its appearance can be adjusted to the users' needs and it is updated regularly, as new stations or changes to those that already exist can be submitted online. The map shows the current situation of pollen and spore monitoring and facilitates collaboration among those individuals who are interested in pollen and spore counts. It might also help to improve the

  7. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    Science.gov (United States)

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the

  8. Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Hunter, S.W.; Gallegos, G.M.; Surano, K.A.; Lamson, K.C.; Tate, P.J.; Balke, B.K.; Biermann, A.H.; Hoppes, W.G.; Fields, B.C.; Gouveia, F.J.; Berger, R.L.; Miller, F.S.; Rueppel, D.W.; Sims, J.M.

    1992-04-01

    The primary tasks of the environmental monitoring section (EMS) Livermore National Laboratory (LLNL) are: effluent monitoring of air, sewer, and NPDES water. Surveillance monitoring of soil, vegetation and foodstuff, water, air particulate, and air tritium. Radiation monitoring, dose assessment, emergency response, quality assurance, and reporting. This report describes LLNL and the monitoring plan

  9. Proof of Concept for a Simple Smartphone Sky Monitor

    Science.gov (United States)

    Kantamneni, Abhilash; Nemiroff, R. J.; Brisbois, C.

    2013-01-01

    We present a novel approach of obtaining a cloud and bright sky monitor by using a standard smartphone with a downloadable app. The addition of an inexpensive fisheye lens can extend the angular range to the entire sky visible above the device. A preliminary proof of concept image shows an optical limit of about visual magnitude 5 for a 70-second exposure. Support science objectives include cloud monitoring in a manner similar to the more expensive cloud monitors in use at most major astronomical observatories, making expensive observing time at these observatories more efficient. Primary science objectives include bright meteor tracking, bright comet tracking, and monitoring the variability of bright stars. Citizen science objectives include crowd sourcing of many networked sky monitoring smartphones typically in broader support of many of the primary science goals. The deployment of a citizen smartphone array in an active science mode could leverage the sky monitoring data infrastructure to track other non-visual science opportunities, including monitoring the Earth's magnetic field for the effects of solar flares and exhaustive surface coverage for strong seismic events.

  10. Uncertainty analysis in the task of individual monitoring data

    International Nuclear Information System (INIS)

    Molokanov, A.; Badjin, V.; Gasteva, G.; Antipin, E.

    2003-01-01

    Assessment of internal doses is an essential component of individual monitoring programmes for workers and consists of two stages: individual monitoring measurements and interpretation of the monitoring data in terms of annual intake and/or annual internal dose. The overall uncertainty in assessed dose is a combination of the uncertainties in these stages. An algorithm and a computer code were developed for estimating the uncertainties in these stages. An algorithm and a computer code were developed for estimating the uncertainty in the assessment of internal dose in the task of individual monitoring data interpretation. Two main influencing factors are analysed in this paper: the unknown time of the exposure and variability of bioassay measurements. The aim of this analysis is to show that the algorithm is applicable in designing an individual monitoring programme for workers so as to guarantee that the individual dose calculated from individual monitoring measurements does not exceed a required limit with a certain confidence probability. (author)

  11. Integrating structural health and condition monitoring

    DEFF Research Database (Denmark)

    May, Allan; Thöns, Sebastian; McMillan, David

    2015-01-01

    window’ allowing for the possible detection of faults up to 6 months in advance. The SHM system model uses a reduction in the probability of failure factor to account for lower modelling uncertainties. A case study is produced that shows a reduction in operating costs and also a reduction in risk......There is a large financial incentive to minimise operations and maintenance (O&M) costs for offshore wind power by optimising the maintenance plan. The integration of condition monitoring (CM) and structural health monitoring (SHM) may help realise this. There is limited work on the integration...

  12. Cycle 24 COS FUV Internal/External Wavelength Scale Monitor

    Science.gov (United States)

    Fischer, William J.

    2018-02-01

    We report on the monitoring of the COS FUV wavelength scale zero-points during Cycle 24 in program 14855. Select cenwaves were monitored for all FUV gratings at Lifetime Position 3. The target and cenwaves have remained the same since Cycle 21, with a change only to the target acquisition sequence. All measured offsets are within the error goals, although the G140L cenwaves show offsets at the short-wavelength end of segment A that are approaching the tolerance. This behavior will be closely monitored in subsequent iterations of the program.

  13. Rapid monitoring particulate radiocesium with nonwoven fabric cartridge filter and application to field monitoring

    International Nuclear Information System (INIS)

    Tsuji, Hideki; Yasutaka, Tetsuo; Kondo, Yoshihiko; Kawashima, Shoji

    2013-01-01

    A method for rapid monitoring particulate radiocesium using a nonwoven fabric cartridge filter was developed, which needs no further preprocessing before served to a detector. By a performance test, more than 98% of suspended solid (SS) was collected. This method showed the same radioactivity measurement accuracy as filtration by membrane filter and more rapid extraction capability of SS. (author)

  14. Development of on-line monitoring system for flow accelerated corrosion

    International Nuclear Information System (INIS)

    Lee, N.Y.; Lee, S.G.; Hwang, I.S.; Kim, J.T.; Luk, V.K.

    2005-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Therefore, we need diverse sensors which can cover wide area in the on-line application. We suggested integrated approach to monitor the FAC-susceptible piping. Since FAC is a combined phenomenon, we need to monitor as many parameters as possible, and that cover wide area, since we don't know where the FAC occurs. For this purpose, we introduced wearing rate model, which concentrates on the electrochemical parameters. By the model, we can predict the wearing rate and then can compare the testing result. After we identified feasibility by analytical way, we developed electrochemical sensors for high temperature application, and introduced mechanical monitoring system, which is still under development. To support the validation of the monitored results, we adopted high temperature UT, which shows good resolution in the testing environment. By this way, all the monitored results can be compared in terms of thickness. Validation test shows the feasibility of sensors. To support direct thickness measurement for wide-area, Direct Current Potential Drop method will be researched to integrate to the developed framework. (authors)

  15. Mercury emission monitoring on municipal waste combustion

    International Nuclear Information System (INIS)

    Braun, H.; Gerig, A.

    1991-01-01

    In waste incineration, mercury is the only heavy metal to be released as a gas, mostly as mercury(II) chloride, because of its high volatility. Continuous emission monitoring is possible only when mercury occurs in its elemental form. This paper reports on various possibilities of converting Hg(II) into Hg(0) that has been studied and tested on a laboratory scale and in the TAMARA refuse incineration pilot facility. Continuous mercury emission measurement appears to be possible, provided mercury is converted in the flue gas condensate precipitated. The measuring results obtained on two municipal solid waste and on one sewage treatment sludge incineration plants show that the mercury monitor is a highly sensitive and selective continuously working instrument for mercury emission monitoring

  16. Proposal for Monitoring Within the Centrifuge Cascades of Uranium Enrichment Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Farrar, David R.

    2017-04-01

    Safeguards are technical measures implemented by the International Atomic Energy Agency (IAEA) to independently verify that nuclear material is not diverted from peaceful purposes to weapons (IAEA, 2017a). Safeguards implemented at uranium enrichment facilities (facilities hereafter) include enrichment monitors (IAEA, 2011). Figure 1 shows a diagram of how a facility could be monitored. The use of a system for monitoring within centrifuge cascades is proposed.

  17. 24-HOUR ELECTROCARDIOGRAPHY IN CLINICAL HEALTHY CAVALIER KING CHARLES SPANIELS, WIRE-HAIRED DACHSHUNDS AND CAIRN TERRIERS

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Vesterholm, Stina; Ludvigsen, Trine Pagh

    2010-01-01

    analysis were analyzed for influence by breed, age, gender, relevant heart rate (HR) parameters and bodyweight. CKCS had a significantly higher HRex (mean 121 ± SD 12 bpm) compared to wD (94±18 bpm) (P>0.0001) and CT (102±16bpm) (P=0.0009). The minimum HR (HRmin) measured during Holter recording...... was significantly higher in CKCS (51±10 bpm) compared to wD (42±7 bpm) (P=0.001) and CT (45±7 bpm) (P=0.05). In addition, CKCS had a higher mean HR (HRmean) during Holter recording (83±13 bpm) compared to wD (68±8 bpm) (P>0.0001) and CT (75±10 bpm) (P=0.04). Both HRmean (P>0.0001) and HRmin (P=0.001) were...

  18. Monitoring road traffic congestion using a macroscopic traffic model and a statistical monitoring scheme

    KAUST Repository

    Zeroual, Abdelhafid; Harrou, Fouzi; Sun, Ying; Messai, Nadhir

    2017-01-01

    Monitoring vehicle traffic flow plays a central role in enhancing traffic management, transportation safety and cost savings. In this paper, we propose an innovative approach for detection of traffic congestion. Specifically, we combine the flexibility and simplicity of a piecewise switched linear (PWSL) macroscopic traffic model and the greater capacity of the exponentially-weighted moving average (EWMA) monitoring chart. Macroscopic models, which have few, easily calibrated parameters, are employed to describe a free traffic flow at the macroscopic level. Then, we apply the EWMA monitoring chart to the uncorrelated residuals obtained from the constructed PWSL model to detect congested situations. In this strategy, wavelet-based multiscale filtering of data has been used before the application of the EWMA scheme to improve further the robustness of this method to measurement noise and reduce the false alarms due to modeling errors. The performance of the PWSL-EWMA approach is successfully tested on traffic data from the three lane highway portion of the Interstate 210 (I-210) highway of the west of California and the four lane highway portion of the State Route 60 (SR60) highway from the east of California, provided by the Caltrans Performance Measurement System (PeMS). Results show the ability of the PWSL-EWMA approach to monitor vehicle traffic, confirming the promising application of this statistical tool to the supervision of traffic flow congestion.

  19. Monitoring road traffic congestion using a macroscopic traffic model and a statistical monitoring scheme

    KAUST Repository

    Zeroual, Abdelhafid

    2017-08-19

    Monitoring vehicle traffic flow plays a central role in enhancing traffic management, transportation safety and cost savings. In this paper, we propose an innovative approach for detection of traffic congestion. Specifically, we combine the flexibility and simplicity of a piecewise switched linear (PWSL) macroscopic traffic model and the greater capacity of the exponentially-weighted moving average (EWMA) monitoring chart. Macroscopic models, which have few, easily calibrated parameters, are employed to describe a free traffic flow at the macroscopic level. Then, we apply the EWMA monitoring chart to the uncorrelated residuals obtained from the constructed PWSL model to detect congested situations. In this strategy, wavelet-based multiscale filtering of data has been used before the application of the EWMA scheme to improve further the robustness of this method to measurement noise and reduce the false alarms due to modeling errors. The performance of the PWSL-EWMA approach is successfully tested on traffic data from the three lane highway portion of the Interstate 210 (I-210) highway of the west of California and the four lane highway portion of the State Route 60 (SR60) highway from the east of California, provided by the Caltrans Performance Measurement System (PeMS). Results show the ability of the PWSL-EWMA approach to monitor vehicle traffic, confirming the promising application of this statistical tool to the supervision of traffic flow congestion.

  20. Low-cost automatic station for compost temperature monitoring

    Directory of Open Access Journals (Sweden)

    Marcelo D. L. Jordão

    Full Text Available ABSTRACT Temperature monitoring is an important procedure to control the composting process. Due to cost limitation, temperature monitoring is manual and with daily sampling resolution. The objective of this study was to develop an automatic station with US$ 150 dollars, able to monitor air temperature at two different points in a compost pile, with a 5-min time resolution. In the calibration test, the sensors showed an estimated uncertainty from ± 1 to ± 1.9 ºC. In the field validation test, the station guaranteed secure autonomy for seven days and endured high humidity and extreme temperature (> 70 °C.

  1. The Pajarito Monitor: a high-sensitivity monitoring system for highly enriched uranium

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Coop, K.; Garcia, C.; Martinez, J.

    1984-01-01

    The Pajarito Monitor for Special Nuclear Material is a high-sensitivity gamma-ray monitoring system for detecting small quantities of highly enriched uranium transported by pedestrians or motor vehicles. The monitor consists of two components: a walk-through personnel monitor and a vehicle monitor. The personnel monitor has a plastic-scintillator detector portal, a microwave occupancy monitor, and a microprocessor control unit that measures the radiation intensity during background and monitoring periods to detect transient diversion signals. The vehicle monitor examines stationary motor vehicles while the vehicle's occupants pass through the personnel portal to exchange their badges. The vehicle monitor has four groups of large plastic scintillators that scan the vehicle from above and below. Its microprocessor control unit measures separate radiation intensities in each detector group. Vehicle occupancy is sensed by a highway traffic detection system. Each monitor's controller is responsible for detecting diversion as well as serving as a calibration and trouble-shooting aid. Diversion signals are detected by a sequential probability ratio hypothesis test that minimizes the monitoring time in the vehicle monitor and adapts itself well to variations in individual passage speed in the personnel monitor. Designed to be highly sensitive to diverted enriched uranium, the monitoring system also exhibits exceptional sensitivity for plutonium

  2. Seeking surprise : rethinking monitoring for collective learning in rural resource management

    NARCIS (Netherlands)

    Guijt, I.M.

    2008-01-01

    Commonsense says that monitoring systems should be able to provide feedback that can help correct ineffective actions. But practice shows that when dealing with complex rural development issues that involve collaborative action by a changing configuration of stakeholders, monitoring practice often

  3. Visual monitoring of reproduction in dairy herds

    DEFF Research Database (Denmark)

    Thysen, Iver; Enevoldsen, Carsten

    1994-01-01

    Two complementary approaches to produce visual information from reproduction records are described and exemplified. The Event Display shows all reproductive events, over a year, for all cows in a herd, by symbols placed in an array with columns representing calendar weeks and rows representing...... individual cows. The Reproduction Monitor consists of graphs of insemination and pregnancy rates evaluated weekly with a Bayesian technique. These visual monitoring tools are well suited to explore temporal variation in reproductive performance, they provide a quick overview of herd performance...

  4. Software for marine ecological environment comprehensive monitoring system based on MCGS

    Science.gov (United States)

    Wang, X. H.; Ma, R.; Cao, X.; Cao, L.; Chu, D. Z.; Zhang, L.; Zhang, T. P.

    2017-08-01

    The automatic integrated monitoring software for marine ecological environment based on MCGS configuration software is designed and developed to realize real-time automatic monitoring of many marine ecological parameters. The DTU data transmission terminal performs network communication and transmits the data to the user data center in a timely manner. The software adopts the modular design and has the advantages of stable and flexible data structure, strong portability and scalability, clear interface, simple user operation and convenient maintenance. Continuous site comparison test of 6 months showed that, the relative error of the parameters monitored by the system such as temperature, salinity, turbidity, pH, dissolved oxygen was controlled within 5% with the standard method and the relative error of the nutrient parameters was within 15%. Meanwhile, the system had few maintenance times, low failure rate, stable and efficient continuous monitoring capabilities. The field application shows that the software is stable and the data communication is reliable, and it has a good application prospect in the field of marine ecological environment comprehensive monitoring.

  5. Application of toxicity monitor using nitrifying bacteria biosensor to sewerage systems.

    Science.gov (United States)

    Inui, T; Tanaka, Y; Okayas, Y; Tanaka, H

    2002-01-01

    Toxic substances may be included in wastewater influent and can damage biological processing of wastewater treatment, therefore continuous toxic-monitoring of wastewater influent is needed. This paper describes the potential toxic-monitoring applications of the toxicity monitor using a nitrifying bacteria biosensor to sewerage systems. The results of sensitivity tests show that aspects of wastewater do not affect the sensor sensitivity and confirm that the sensor can be applied to wastewater monitoring as it is. The monitor with a prototype of filtration system installed in a wastewater treatment plant is able to operate continuously for one month at least after the modification of filtration system and the optimization of operation conditions.

  6. Environmental Monitoring Plan

    Energy Technology Data Exchange (ETDEWEB)

    Holland, R.C. [Science Applications International Corp., San Diego, CA (United States)

    1993-07-01

    This Environmental Monitoring Plan was written to fulfill the requirements of Department of Energy (DOE) Order 5400.1 and DOE Environmental Regulatory Guide DOE/EH 0173T. This Plan documents the background, organizational structure, and methods used for effluent monitoring and environmental surveillance at Sandia National Laboratories/California. The design, rationale, and historical results of the environmental monitoring system are discussed in detail. Throughout the Plan, recommendations for improvements to the monitoring system are made. This revision to the Environmental Monitoring Plan was written to document the changes made to the Monitoring Program during 1992. Some of the data (most notably the statistical analyses of past monitoring data) has not been changed.

  7. Environmental Monitoring Plan

    International Nuclear Information System (INIS)

    Holland, R.C.

    1993-07-01

    This Environmental Monitoring Plan was written to fulfill the requirements of Department of Energy (DOE) Order 5400.1 and DOE Environmental Regulatory Guide DOE/EH 0173T. This Plan documents the background, organizational structure, and methods used for effluent monitoring and environmental surveillance at Sandia National Laboratories/California. The design, rationale, and historical results of the environmental monitoring system are discussed in detail. Throughout the Plan, recommendations for improvements to the monitoring system are made. This revision to the Environmental Monitoring Plan was written to document the changes made to the Monitoring Program during 1992. Some of the data (most notably the statistical analyses of past monitoring data) has not been changed

  8. Dynamic generalized linear models for monitoring endemic diseases

    DEFF Research Database (Denmark)

    Lopes Antunes, Ana Carolina; Jensen, Dan; Hisham Beshara Halasa, Tariq

    2016-01-01

    The objective was to use a Dynamic Generalized Linear Model (DGLM) based on abinomial distribution with a linear trend, for monitoring the PRRS (Porcine Reproductive and Respiratory Syndrome sero-prevalence in Danish swine herds. The DGLM was described and its performance for monitoring control...... and eradication programmes based on changes in PRRS sero-prevalence was explored. Results showed a declining trend in PRRS sero-prevalence between 2007 and 2014 suggesting that Danish herds are slowly eradicating PRRS. The simulation study demonstrated the flexibility of DGLMs in adapting to changes intrends...... in sero-prevalence. Based on this, it was possible to detect variations in the growth model component. This study is a proof-of-concept, demonstrating the use of DGLMs for monitoring endemic diseases. In addition, the principles stated might be useful in general research on monitoring and surveillance...

  9. Results of Monitoring at Olkiluoto in 2009. Hydrogeochemistry

    International Nuclear Information System (INIS)

    Penttinen, T.; Lahdenperae, A.-M.; Ahokas, T.; Partamies, S.; Kasa, S.; Pitkaenen, P.

    2011-01-01

    The construction work of underground research facility ONKALO started in the autumn 2004. Possible changes caused by the construction of the disposal facility in the chemical environment in shallow and deep groundwaters are monitored on a regular basis. This report presents the hydrogeochemical monitoring measurements and observations made in 2009. A total of 31 shallow groundwater samples were taken in monitoring programme and 49 shallow groundwater samples in the Infiltration experiment area in 2009. The sampling points of shallow groundwaters were divided into groups on a basis of their typical geological and geographic features. The seasonal variation in concentration levels was now clearly observed in OL-PVP3A, OL-PVP13, OL-PVP14, OL-PVP17, OL-PVP18A, OL-PVP20, OL-PP39 and OL-PP56. This behaviour is related to high naturally fluctuating concentrations in these sampling sites. The effect of Korvensuo on the groundwater of OL-PVP30 appeared. No straight connection can be made with the ONKALO construction work and the observed changes in shallow groundwater concentrations. 47 deep groundwater samplings were carried out during the year 2009 from 19 different drillholes and 30 groundwater samples were taken from ONKALO. 10 gas samples have been analysed and collected from 6 open drillholes during the year 2009 and 5 are from sampling points of ONKALO. The results from ground surface based monitoring campaign in 2009 show indications of changes in groundwater compositions, which are most probably caused by high hydraulic gradient of ONKALO. The 2009 results show slight but clear systematic dilution (in all species) in two monitoring points (OL-KR4 T 76 and OL-KR37 T 165, both intersections of HZ19) relative to the previous samplings. Of the monitored intersections of hydraulic zone HZ20B the OL-KR10 T 326 have continued dilution trend (after packering) and OL-KR9 T 468 and OL-KR23 T 424 h ave become more saline. Particularly the start of salinity increase in OL-KR9

  10. BIOSENSORS FOR ENVIRONMENTAL MONITORING: A REGULATORY PERSPECTIVE

    Science.gov (United States)

    Biosensors show the potential to complement laboratory-based analytical methods for environmental applications. Although biosensors for potential environmental-monitoring applications have been reported for a wide range of environmental pollutants, from a regulatory perspective, ...

  11. Monitoring in beeld: een studie naar de doorwerking van monitors in interbestuurlijke relaties

    NARCIS (Netherlands)

    D. de Kool (Dennis)

    2007-01-01

    textabstractMonitoring in the Dutch public sector An increasing stream of monitoring activities has entered the public sector. A lot of different monitors have been implemented in the Netherlands, like the police monitor, drugs monitor, integration monitor and the emancipation monitor. Although

  12. Three Sisters Dam: Investigations and monitoring

    International Nuclear Information System (INIS)

    Slopek, R.J.; Courage, L.J.R.; Keys, R.A.

    1990-01-01

    The geotechnical investigations, monitoring and interpretation of data associated with the evaluation of the Three Sisters Dam, which has been suffering from excessive seepage and is in need of enhancement, are outlined. The Three Sisters Dam is located in the continental ranges of the Rocky Mountains in Alberta, impounding the Spray Reservoir, and is founded on 60 m of interbedded sand, gravel, silt and clay layers. The computer code PC-SEEP was used to evaluate seepage. Details are provided of drilling, ground-penetrating radar surveys, seismic surveys, penstock inspection, sinkhole activity, piezometer monitoring, silt wells, settlement monuments, and tailrace monitoring. The intensive investigations of the foundations showed that they consist of a complex formation of interfingered stratified layers and leases of talus and glaciofluvial deposits. Due to the depth and nature of these materials drill hole penetration was limited to the use of the Becker hammer. This equipment successfully delineated the major soil horizons of the foundation. The continued information attained from inspection, drilling, testing, radar surveys, seismic work, monitoring of piezometers, leakage, silt wells and settlement monuments indicated that there are no large voids within the foundation of the dam. 2 refs., 12 figs

  13. Air pollution monitoring in Amman, Jordan

    International Nuclear Information System (INIS)

    Al-Hasaan, A.A.; Dann, T.F.; Brunet, P.F.

    1992-01-01

    In 1985, a collaborative research program was established between the Royal Scientific Society of Jordan and Environment Canada, Pollution Measurement Division, Ottawa, Canada, with the objective of developing an air pollution monitoring network for Amman and preparing recommendations for national air quality standards and national emission standards for Jordan. Four monitoring sites were established in residential and commercial areas of Amman. Carbon monoxide, nitrogen dioxide, sulphur dioxide and total suspended particle matter (TSP) were measured at the Downtown station. At the other sites only TSP was measured. A short-term monitoring program carried out with a mobile monitoring unit showed relatively low levels of sulfur dioxide, carbon monoxide and nitrogen dioxide at the RSS, Naser and Marka sites as compared to the Downtown site. Continuous analyzers purchased from Environment SA, France, were used to measure sulfur dioxide, carbon monoxide and nitrogen dioxide; Sierra-Anderson high volume samplers equipped with glass fiber filters were used to collect total suspended particulates samples. Gaseous pollutants were continuously measured at the Downtown site and TSP samplers were operated on a three day schedule at all sites. Sampling began in July 1986 and continues to the present

  14. Monitoring system of arch bridge for safety network management

    Science.gov (United States)

    Joo, Bong Chul; Yoo, Young Jun; Lee, Chin Hyung; Park, Ki Tae; Hwang, Yoon Koog

    2010-03-01

    Korea has constructed the safety management network monitoring test systems for the civil infrastructure since 2006 which includes airport structure, irrigation structure, railroad structure, road structure, and underground structure. Bridges among the road structure include the various superstructure types which are Steel box girder bridge, suspension bridge, PSC-box-girder bridge, and arch bridge. This paper shows the process of constructing the real-time monitoring system for the arch bridge and the measured result by the system. The arch type among various superstructure types has not only the structural efficiency but the visual beauty, because the arch type superstructure makes full use of the feature of curve. The main measuring points of arch bridges composited by curved members make a difference to compare with the system of girder bridges composited by straight members. This paper also shows the method to construct the monitoring system that considers the characteristic of the arch bridge. The system now includes strain gauges and thermometers, and it will include various sensor types such as CCTV, accelerometers and so on additionally. For the long term and accuracy monitoring, the latest optical sensors and equipments are applied to the system.

  15. A Coupled model for ERT monitoring of contaminated sites

    Science.gov (United States)

    Wang, Yuling; Zhang, Bo; Gong, Shulan; Xu, Ya

    2018-02-01

    The performance of electrical resistivity tomography (ERT) system is usually investigated using a fixed resistivity distribution model in numerical simulation study. In this paper, a method to construct a time-varying resistivity model by coupling water transport, solute transport and constant current field is proposed for ERT monitoring of contaminated sites. Using the proposed method, a monitoring model is constructed for a contaminated site with a pollution region on the surface and ERT monitoring results at different time is calculated by the finite element method. The results show that ERT monitoring profiles can effectively reflect the increase of the pollution area caused by the diffusion of pollutants, but the extent of the pollution is not exactly the same as the actual situation. The model can be extended to any other case and can be used to scheme design and results analysis for ERT monitoring.

  16. MONITORING ON PLANT LEAF WATER POTENTIAL USING NIR SPECTROSCOPY FOR WATER STRESS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Diding Suhandy

    2012-12-01

    Full Text Available The performance of the calibration model with temperature compensation for on-plant leaf water potential (LWP determination in tomato plants was evaluated. During a cycle of water stress, the on-plant LWP measurement was conducted. The result showed that the LWP values under water stress and recovery from water stress could be monitored well. It showed that a real time monitoring of the LWP values using NIR spectroscopy could be possible.   Keywords: water stress, real time monitoring of leaf water potential, NIR spectroscopy, plant response-based

  17. Monitoring in educational development projects : the development of a monitoring system

    NARCIS (Netherlands)

    Plomp, T.; Huijsman, Hari; Kluyfhout, Eric

    1992-01-01

    Monitoring in education is usually focused on the monitoring of educational systems at different levels. Monitoring of educational projects receives only recently explicit attention. The paper discusses first the concepts of educational monitoring and evaluation. After that, the experience with

  18. Monitoring programme. Radioactive substances report for 1994

    International Nuclear Information System (INIS)

    1995-09-01

    In the United Kingdom, Her Majesty's Inspectorate of Pollution commissions independent monitoring of radioactive discharges to the environment. This report presents the results of such monitoring for 1994. It covers nuclear sites, two non-nuclear sites which use large amounts of tritium and several landfill sites which receive low-level radioactive waste for controlled burial. The monitoring programme concentrates on activity levels in environmental materials that might result in exposure of the public to radiation from non-food pathways. The results show that exposures from these pathways in 1994 remain similar to those in previous years and in all cases are estimated to have been substantially lower than the International Commission on Radiological Protection's recommended dose limit of 1mSv per year. (6 figures; 20 tables; 29 references) (UK)

  19. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  20. Environmental monitoring plan - environmental monitoring section. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Wilt, G.C. [ed.; Tate, P.J.; Brigdon, S.L. [and others

    1994-11-01

    This report presents the environmental monitoring plan for the Lawrence Livermore National Laboratory. A site characterization is provided along with monitoring and measurement techniques and quality assurance measures.

  1. Environmental monitoring plan - environmental monitoring section. Revision 1

    International Nuclear Information System (INIS)

    Wilt, G.C.; Tate, P.J.; Brigdon, S.L.

    1994-11-01

    This report presents the environmental monitoring plan for the Lawrence Livermore National Laboratory. A site characterization is provided along with monitoring and measurement techniques and quality assurance measures

  2. Vibration-based monitoring and diagnostics using compressive sensing

    Science.gov (United States)

    Ganesan, Vaahini; Das, Tuhin; Rahnavard, Nazanin; Kauffman, Jeffrey L.

    2017-04-01

    Vibration data from mechanical systems carry important information that is useful for characterization and diagnosis. Standard approaches rely on continually streaming data at a fixed sampling frequency. For applications involving continuous monitoring, such as Structural Health Monitoring (SHM), such approaches result in high volume data and rely on sensors being powered for prolonged durations. Furthermore, for spatial resolution, structures are instrumented with a large array of sensors. This paper shows that both volume of data and number of sensors can be reduced significantly by applying Compressive Sensing (CS) in vibration monitoring applications. The reduction is achieved by using random sampling and capitalizing on the sparsity of vibration signals in the frequency domain. Preliminary experimental results validating CS-based frequency recovery are also provided. By exploiting the sparsity of mode shapes, CS can also enable efficient spatial reconstruction using fewer spatially distributed sensors. CS can thereby reduce the cost and power requirement of sensing as well as streamline data storage and processing in monitoring applications. In well-instrumented structures, CS can enable continued monitoring in case of sensor or computational failures.

  3. [Microinjection Monitoring System Design Applied to MRI Scanning].

    Science.gov (United States)

    Xu, Yongfeng

    2017-09-30

    A microinjection monitoring system applied to the MRI scanning was introduced. The micro camera probe was used to stretch into the main magnet for real-time video injection monitoring of injection tube terminal. The programming based on LabVIEW was created to analysis and process the real-time video information. The feedback signal was used for intelligent controlling of the modified injection pump. The real-time monitoring system can make the best use of injection under the condition that the injection device was away from the sample which inside the magnetic room and unvisible. 9.4 T MRI scanning experiment showed that the system in ultra-high field can work stability and doesn't affect the MRI scans.

  4. When big brother is watching: goal orientation shapes reactions to electronic monitoring during online training.

    Science.gov (United States)

    Watson, Aaron M; Foster Thompson, Lori; Rudolph, Jane V; Whelan, Thomas J; Behrend, Tara S; Gissel, Amanda L

    2013-07-01

    Web-based training is frequently used by organizations as a convenient and low-cost way to teach employees new knowledge and skills. As web-based training is typically unproctored, employees may be held accountable to the organization by computer software that monitors their behaviors. The current study examines how the introduction of electronic performance monitoring may provoke negative emotional reactions and decrease learning among certain types of e-learners. Through motivated action theory and trait activation theory, we examine the role of performance goal orientation when e-learners are exposed to asynchronous and synchronous monitoring. We show that some e-learners are more susceptible than others to evaluation apprehension when they perceive their activities are being monitored electronically. Specifically, e-learners higher in avoid performance goal orientation exhibited increased evaluation apprehension if they believed asynchronous monitoring was present, and they showed decreased skill attainment as a result. E-learners higher on prove performance goal orientation showed greater evaluation apprehension if they believed real-time monitoring was occurring, resulting in decreased skill attainment. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  5. Seeking surprise : rethinking monitoring for collective learning in rural resource management

    OpenAIRE

    Guijt, I.M.

    2008-01-01

    Commonsense says that monitoring systems should be able to provide feedback that can help correct ineffective actions. But practice shows that when dealing with complex rural development issues that involve collaborative action by a changing configuration of stakeholders, monitoring practice often falls short of its potential. In this thesis, I describe my search to understand why practice is so limited and what might be needed to design monitoring processes that foster learning in concerted ...

  6. To monitor or not to monitor?: editorial

    International Nuclear Information System (INIS)

    Johns, T.F.

    1988-01-01

    After a brief discussion about results for occupational exposure in New Zealand and the UK, a short editorial raises a number of questions about personal dosimetry practice. These questions include whether the right people are being monitored and whether less attention should be paid to the monitoring of certain groups of workers who are occupationally exposed to external beta/gamma radiation, and more to the monitoring of workers or members of the general public who are exposed to higher doses from radon daughters, so as to focus attention on the areas where the largest savings in collective dose could be achieved. (U.K.)

  7. Update on the independent radiation monitor (IRM)

    International Nuclear Information System (INIS)

    Kroening, P.M.; Mucha, R.

    1976-01-01

    The new independent radiation monitor (IRM), unlike its predecessor, is a reliable and sensitive safety device for any radiation therapy room. It shows unequivocally that the beam is on, and it is inexpensive and simple to construct

  8. Monitoring biodiesel reactions of soybean oil and sunflower oil using ultrasonic parameters

    International Nuclear Information System (INIS)

    Figueiredo, M K K; Silva, C E R; Alvarenga, A V; Costa-Félix, R P B

    2015-01-01

    Biodiesel is an innovation that attempts to substitute diesel oil with biomass. The aim of this paper is to show the development of a real-time method to monitor transesterification reactions by using low-power ultrasound and pulse/echo techniques. The results showed that it is possible to identify different events during the transesterification process by using the proposed parameters, showing that the proposed method is a feasible way to monitor the reactions of biodiesel during its fabrication, in real time, and with relatively low- cost equipment

  9. Monitoring biodiesel reactions of soybean oil and sunflower oil using ultrasonic parameters

    Science.gov (United States)

    Figueiredo, M. K. K.; Silva, C. E. R.; Alvarenga, A. V.; Costa-Félix, R. P. B.

    2015-01-01

    Biodiesel is an innovation that attempts to substitute diesel oil with biomass. The aim of this paper is to show the development of a real-time method to monitor transesterification reactions by using low-power ultrasound and pulse/echo techniques. The results showed that it is possible to identify different events during the transesterification process by using the proposed parameters, showing that the proposed method is a feasible way to monitor the reactions of biodiesel during its fabrication, in real time, and with relatively low- cost equipment.

  10. Helmet-based physiological signal monitoring system.

    Science.gov (United States)

    Kim, Youn Sung; Baek, Hyun Jae; Kim, Jung Soo; Lee, Haet Bit; Choi, Jong Min; Park, Kwang Suk

    2009-02-01

    A helmet-based system that was able to monitor the drowsiness of a soldier was developed. The helmet system monitored the electrocardiogram, electrooculogram and electroencephalogram (alpha waves) without constraints. Six dry electrodes were mounted at five locations on the helmet: both temporal sides, forehead region and upper and lower jaw strips. The electrodes were connected to an amplifier that transferred signals to a laptop computer via Bluetooth wireless communication. The system was validated by comparing the signal quality with conventional recording methods. Data were acquired from three healthy male volunteers for 12 min twice a day whilst they were sitting in a chair wearing the sensor-installed helmet. Experimental results showed that physiological signals for the helmet user were measured with acceptable quality without any intrusions on physical activities. The helmet system discriminated between the alert and drowsiness states by detecting blinking and heart rate variability (HRV) parameters extracted from ECG. Blinking duration and eye reopening time were increased during the sleepiness state compared to the alert state. Also, positive peak values of the sleepiness state were much higher, and the negative peaks were much lower than that of the alert state. The LF/HF ratio also decreased during drowsiness. This study shows the feasibility for using this helmet system: the subjects' health status and mental states could be monitored without constraints whilst they were working.

  11. Screening and managing obstructive sleep apnoea in nocturnal heart block patients: an observational study.

    Science.gov (United States)

    Wu, Xu; Liu, Zilong; Chang, Su Chi; Fu, Cuiping; Li, Wenjing; Jiang, Hong; Jiang, Liyan; Li, Shanqun

    2016-02-16

    Nocturnal heart block often occurs in patients with obstructive sleep apnoea (OSA). It is more likely to be undiagnosed in heart block patients who are ignorant of the symptoms of sleep disorder. Berlin Questionnaire (BQ) is a highly reliable way to discover the risk factors of OSA, whereas the validity in sleep-related heart block patients is uncertain. We performed an observational study to address these issues and confirmed the potential protective effect of continuous positive airway pressure (CPAP). Patients who were previously diagnosed with nocturnal heart block with R-R pauses exceeding 2 seconds were retrospective screened from the ECG centre of Zhongshan hospital. These recruited participants completed Berlin Questionnaire and underwent polysomnography synchronously with 24-hour Holter monitoring. A cross-sectional analysis was performed to confirm the association between nocturnal arrhythmia and OSA, as well as to assess the diagnostic accuracy of the BQ. Subsequently, subjects diagnosed with OSA (apnoea-hypopnoea index > 5) underwent 3 consecutive days of CPAP therapy. On the third day, patients repeated 24-hour Holter monitoring within the institution of CPAP. The symptoms of disruptive snoring and hypersomnolence in 72 enrolled patients were more related to the occurrence of nocturnal heart block (r = 0.306, 0.226, respectively, p = 0.015, 0.019) than syncope (r = 0.134, p = 0.282) and palpitations (r = 0.106, p = 0.119), which were prominent trait of our study population. The sensitivity, specificity, positive and negative predictive value of the BQ at a cut-off point of 5 of AHI for detecting OSA in heart block patients was 81.0 %, 44.4 %, 91.07 % and 25 %. Nocturnal heart block does not appear to occur exclusively in severe sleep apnoea. The frequent occurrence of arrhythmias in prominent oxygen desaturation supports the correlation between them. CPAP therapy resulted in significant decrease in the average number of

  12. Development of an On-Line Uranium Enrichment Monitor

    International Nuclear Information System (INIS)

    Xuesheng, L.; Guorong, L.; Yonggang, Z.; Xueyuan, H. X.-Y.

    2015-01-01

    An on-line enrichment monitor was developed to measure the enrichment of UF6 flowing through the processing pipes in centrifuge uranium enrichment plant. A NaI(Tl) detector was used to measure the count rates of the 186 keV gamma ray emitted from 235U, and the total quantity of uranium was determined from thermodynamic characteristics of gaseous uranium hexafluoride. The results show that the maximum relative standard deviation is less than 1% when the measurement time is 120 s or more and the pressure is more than 2 kPa in the measurement chamber. There are two working models for the monitor. The monitor works normally in the continuous model, When the gas's pressure in the pipe fluctuates greatly, it can work in the intermittent model, and the measurement result is very well. The background of the monitor can be measured automatically periodically. It can control automatically electromagnetic valves open and close, so as to change the gas's quantity in the chamber. It is a kind of unattended and remote monitor, all of data can be transfer to central control room. It should be effective for nuclear materials accountability verifications and materials balance verification at uranium enrichment plant by using the monitor to monitor Uranium enrichment of gaseous uranium hexafluoride in the output end of cascade continuously. (author)

  13. Design of Kartini reactor radiation monitor system using lab view

    International Nuclear Information System (INIS)

    Adi Abimanyu; Jumari; Achmad Fahrul Aji; Muhammad Khoiri

    2014-01-01

    Kartini Reactor operation will result in radiation exposure. Gamma radiation exposure rate at the Kartini Reactor monitored by several radiation monitors (Ludlum) that integrate with the computer, so that the rate of radiation exposure is always monitored. Current monitoring system combines six radiation monitor in one computer monitor radiation, and monitoring performed by operators and supervisors to see how the radiation exposure rate measured in the area around the reactor core in a periodic time manually. This research will develop a system to monitor radiation exposure in Kartini reactor based ATMega8 micro controller for interface between radiation monitor and computer and also Graphical User Interface (GUI) develop using Lab view software that makes monitoring is easier and documented regularly. This system is testing by simulation, it is done by replacing the function of the radiation monitoring devices (Ludlum) in Kartini Reactor with computers that send serial data with the same format with a format that is sent by Ludlum. The results show that the interface system has the ability to operate in a range of baud rate 1,200 bps, 2,400 bps, 4,800 bps, 9,600 bps, 14,400 bps, 19,200 bps and 38,400 bps, with the ability to provide realtime information every 6 seconds and able to document the rate of exposure to radiation in the form of logbook. (author)

  14. Radon monitoring technique with electret collecting

    International Nuclear Information System (INIS)

    Tian Zhiheng; Zuo Fuqi; Xiao Detao; Zhao Xkiuliang

    1991-12-01

    The integrating radon monitoring technique with electret collecting is a method which collects the 218 Po + positive ions by electrostatic field produced by electret. It has greatly improved the sensitivity of radon measurement. The response factor of this method reaches to 4.7 cm -2 Bq -1 m 3 h -1 , 1000 times larger than that of common passive sampling method. The monitoring device and its principle are introduced. The measuring results of radon concentration and radon flux rate and quality assurance system by using this method in the Qinshan Nuclear Power Plant, Human Environmental Monitoring Central Station and some uranium mines are also presented. The analytical results show that the radon concentration in the Qinshan Nuclear Power Plant is affected by wind direction. When wind directs toward sea, the radon concentration is high. If the wind is to the contrary, it is low. The radon concentration ratio of both is about 2

  15. Environmental radiation monitoring of Vizag City

    International Nuclear Information System (INIS)

    Sreekanth, B.; Narsaiah, M.V.R.; Saindane, Shashank; Pujari, Raju; Krishna, N.S.; Sambamurthy, T.; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiological impact assessment is to be carried out following any radiological emergency to implement the required counter measures. A ground based environmental radiation monitoring of Vizag city has been carried out by installing various radiation monitoring instruments in a vehicle to generate the base line radiation data. It also helps to check the illicit trafficking of radioactive sources and also identifying the orphan sources. The average background radiation level observed in Vizag city was 80 nGy/h. Database of baseline radiation level with GPS location at all important locations of the whole city has been developed. No illicit trafficking of radioactive materials and orphan sources were detected during the survey. All the detectors used in the survey shown good correlation in their response. The study showed that mobile monitoring methodology will be useful in the quick assessment of radiological impact and strengthens the decision makers in reducing consequences by initiating immediate counter measures

  16. Performance monitoring and error significance in patients with obsessive-compulsive disorder.

    Science.gov (United States)

    Endrass, Tanja; Schuermann, Beate; Kaufmann, Christan; Spielberg, Rüdiger; Kniesche, Rainer; Kathmann, Norbert

    2010-05-01

    Performance monitoring has been consistently found to be overactive in obsessive-compulsive disorder (OCD). The present study examines whether performance monitoring in OCD is adjusted with error significance. Therefore, errors in a flanker task were followed by neutral (standard condition) or punishment feedbacks (punishment condition). In the standard condition patients had significantly larger error-related negativity (ERN) and correct-related negativity (CRN) ampliudes than controls. But, in the punishment condition groups did not differ in ERN and CRN amplitudes. While healthy controls showed an amplitude enhancement between standard and punishment condition, OCD patients showed no variation. In contrast, group differences were not found for the error positivity (Pe): both groups had larger Pe amplitudes in the punishment condition. Results confirm earlier findings of overactive error monitoring in OCD. The absence of a variation with error significance might indicate that OCD patients are unable to down-regulate their monitoring activity according to external requirements. Copyright 2010 Elsevier B.V. All rights reserved.

  17. A simple, remote, video based breathing monitor.

    Science.gov (United States)

    Regev, Nir; Wulich, Dov

    2017-07-01

    Breathing monitors have become the all-important cornerstone of a wide variety of commercial and personal safety applications, ranging from elderly care to baby monitoring. Many such monitors exist in the market, some, with vital signs monitoring capabilities, but none remote. This paper presents a simple, yet efficient, real time method of extracting the subject's breathing sinus rhythm. Points of interest are detected on the subject's body, and the corresponding optical flow is estimated and tracked using the well known Lucas-Kanade algorithm on a frame by frame basis. A generalized likelihood ratio test is then utilized on each of the many interest points to detect which is moving in harmonic fashion. Finally, a spectral estimation algorithm based on Pisarenko harmonic decomposition tracks the harmonic frequency in real time, and a fusion maximum likelihood algorithm optimally estimates the breathing rate using all points considered. The results show a maximal error of 1 BPM between the true breathing rate and the algorithm's calculated rate, based on experiments on two babies and three adults.

  18. Monitoring Activities Review action report for the Environmental Monitoring Program

    International Nuclear Information System (INIS)

    Wilhelmsen, R.N.; Wright, K.C.

    1990-12-01

    To improve program planning and to provide bases for technical improvement of the monitoring program, the EG ampersand G Environmental Monitoring (EM) organization has regularly used the Monitoring Activities Review (MAR) process since 1982. Each MAR is conducted by a committee of individuals selected for their experience in the various types of monitoring performed by the EM organization. An MAR of the Environmental Monitoring Program was conducted in 1988. This action report identifies and discusses the recommendations of this MAR committee. This action report also identifies the actions already taken by the EM Unit in response to these recommendations, as well as the actions and schedules to be taken. 10 refs

  19. Process monitoring

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Many of the measurements and observations made in a nuclear processing facility to monitor processes and product quality can also be used to monitor the location and movements of nuclear materials. In this session information is presented on how to use process monitoring data to enhance nuclear material control and accounting (MC and A). It will be seen that SNM losses can generally be detected with greater sensitivity and timeliness and point of loss localized more closely than by conventional MC and A systems if process monitoring data are applied. The purpose of this session is to enable the participants to: (1) identify process unit operations that could improve control units for monitoring SNM losses; (2) choose key measurement points and formulate a loss indicator for each control unit; and (3) describe how the sensitivities and timeliness of loss detection could be determined for each loss indicator

  20. Moisture Content Monitoring of a Timber Footbridge

    Directory of Open Access Journals (Sweden)

    Niclas Björngrim

    2016-03-01

    Full Text Available Construction of modern timber bridges has greatly increased during the last 20 years in Sweden. Wood as a construction material has several advantageous properties, e.g., it is renewable, sustainable, and aesthetically pleasing, but it is also susceptible to deterioration. To protect wood from deterioration and ensure the service life, the wood is either treated or somehow covered. This work evaluates a technology to monitor the moisture content in wood constructions. Monitoring the moisture content is important both to verify the constructive protection and for finding areas with elevated levels of moisture which might lead to a microbiological attack of the wood. In this work, a timber bridge was studied. The structure was equipped with six wireless sensors that measured the moisture content of the wood and the relative humidity every hour. Data for 744 days of the bridge are presented in this paper. Results show that the technology used to monitor the bridge generally works; however, there were issues due to communication problems and malfunction of sensors. This technology is promising for monitoring the state of wood constructions, but a more reliable sensor technology is warranted continuous remote monitoring of wood bridges over long periods of time.

  1. Tool path strategy and cutting process monitoring in intelligent machining

    Science.gov (United States)

    Chen, Ming; Wang, Chengdong; An, Qinglong; Ming, Weiwei

    2018-06-01

    Intelligent machining is a current focus in advanced manufacturing technology, and is characterized by high accuracy and efficiency. A central technology of intelligent machining—the cutting process online monitoring and optimization—is urgently needed for mass production. In this research, the cutting process online monitoring and optimization in jet engine impeller machining, cranio-maxillofacial surgery, and hydraulic servo valve deburring are introduced as examples of intelligent machining. Results show that intelligent tool path optimization and cutting process online monitoring are efficient techniques for improving the efficiency, quality, and reliability of machining.

  2. Investigation progress of imaging techniques monitoring stem cell therapy

    International Nuclear Information System (INIS)

    Wu Jun; An Rui

    2006-01-01

    Recently stem cell therapy has showed potential clinical application in diabetes mellitus, cardiovascular diseases, malignant tumor and trauma. Efficient techniques of non-invasively monitoring stem cell transplants will accelerate the development of stem cell therapies. This paper briefly reviews the clinical practice of stem cell, in addition, makes a review of monitoring methods including magnetic resonance and radionuclide imaging which have been used in stem cell therapy. (authors)

  3. The impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot.

    Science.gov (United States)

    Ávila, Pablo; Marcotte, François; Dore, Annie; Mercier, Lise-Andrée; Shohoudi, Azadeh; Mongeon, François-Pierre; Mondésert, Blandine; Proietti, Anna; Ibrahim, Reda; Asgar, Anita; Poirier, Nancy; Khairy, Paul

    2016-09-15

    Sudden death of presumed arrhythmic etiology is the leading cause of mortality in adults with tetralogy of Fallot. To assess the impact of exercise on ventricular arrhythmias in adults with tetralogy of Fallot. Adults with repaired tetralogy of Fallot were randomized in a 2:1 ratio to an open-label trial of standard care versus 12weeks of supervised combined aerobic/resistance training with continuous Holter monitoring. Proportion of premature ventricular complexes (PVC) and runs of non-sustained ventricular tachycardia (NSVT) were assessed by mixed and Poisson regression models with generalized estimating equations for repeated measures. A total of 152 Holters were performed in 17 patients, median age 35 (interquartile range [IQR] 28, 42) years, 65% male, 13 of whom were randomized to exercise training. Baseline characteristics were similar between groups. Exercise training resulted in significant increases in peak oxygen uptake (11±19%, p=0.028), metabolic equivalents (11±18%, p=0.027), and exercise duration (8±10%, p=0.009) compared to no changes in controls. Frequent (≥30 per hour) PVCs were present in 46% of patients, couplets in 62%, and 3 to 7 beat runs of NSVT in 31%. The median proportion of PVCs was 1.93‰ (IQR 0.41, 5.89) at baseline and 1.45‰ (IQR 0.08, 2.76) during the initial exercise session (p=0.722), and remained stable over time (ß coefficient=-0.031, p=0.408). Runs of NSVT decreased significantly over time (ß coefficient=-0.032, p=0.018). In adults with repaired tetralogy of Fallot, exercise training is safe, improves exercise capacity, and appears to confer a beneficial effect on ventricular arrhythmias. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Fertility and Pregnancy in Turner Syndrome.

    Science.gov (United States)

    Bouet, Pierre-Emmanuel; Godbout, Ariane; El Hachem, Hady; Lefebvre, Maude; Bérubé, Lyne; Dionne, Marie-Danielle; Kamga-Ngande, Carole; Lapensée, Louise

    2016-08-01

    Turner syndrome (TS) occurs in one in 2500 live female births and is one of the most common chromosomal abnormalities in women. Pregnancies in women with TS, conceived with either autologous or donated oocytes, are considered high risk because of the associated miscarriages and life-threatening cardiovascular complications (aortic dissection, severe hypertension). Therefore, it is imperative to conduct a full preconception evaluation and counselling that includes cardiac assessment with Holter blood pressure monitoring, echocardiography, and thoracic MRI. Abnormal findings, such an aortic dilatation, mandate close monitoring throughout the pregnancy and the immediate postpartum period and could possibly contraindicate pregnancy. When in vitro fertilization using donated oocytes is performed in these women, only a single embryo should be transferred. Women with a Turner mosaic karyotype appear to have a lower risk of obstetrical and cardiovascular complications but should nevertheless undergo the full preconception evaluation. In this article, we offer guidelines on the management of women with TS in the preconception period, during pregnancy, and postpartum. Copyright © 2016 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  5. A modern concept for status oriented vibration monitoring of big turbogenerators

    International Nuclear Information System (INIS)

    Herz, F.; Theodor, P.

    1997-01-01

    The investigation of mechanical vibrations is an excellent method of showing the current condition of a machine. This paper deals with the vibrations monitoring of large turbo-generators. First the general aspects of monitoring, as well as diagnostic strategies and impact on the operation of the installation is discussed. An example of a condition-oriented vibration monitoring is the description of the 'Vibroview' system recently developed and installed in the Leibstadt nuclear power plant. (author) 16 figs., tabs., refs

  6. Monitoring of HIV viral load, CD4 cell count, and clinical assessment versus clinical monitoring alone for antiretroviral therapy in low-resource settings (Stratall ANRS 12110/ESTHER) : a cost-effectiveness analysis

    OpenAIRE

    Boyer, S.; March, L.; Kouanfack, C.; Laborde-Balen, G.; Marino, P.; Aghokeng Fobang, Avelin; Mpoudi-Ngole, E.; Koulla-Shiro, S.; Delaporte, Eric; Carrieri, M. P.; Spire, B.; Laurent, Christian; Moatti, Jean-Paul

    2013-01-01

    Background In low-income countries, the use of laboratory monitoring of patients taking antiretroviral therapy (ART) remains controversial in view of persistent resource constraints. The Stratall trial did not show that clinical monitoring alone was non-inferior to laboratory and clinical monitoring in terms of immunological recovery. We aimed to evaluate the costs and cost-effectiveness of the ART monitoring approaches assessed in the Stratall trial. Methods The randomised, controlled, non-i...

  7. Nuclear Explosion Monitoring History and Research and Development

    Science.gov (United States)

    Hawkins, W. L.; Zucca, J. J.

    2008-12-01

    Within a year after the nuclear detonations over Hiroshima and Nagasaki the Baruch Plan was presented to the newly formed United Nations Atomic Energy Commission (June 14, 1946) to establish nuclear disarmament and international control over all nuclear activities. These controls would allow only the peaceful use of atomic energy. The plan was rejected through a Security Council veto primarily because of the resistance to unlimited inspections. Since that time there have been many multilateral, and bilateral agreements, and unilateral declarations to limit or eliminate nuclear detonations. Almost all of theses agreements (i.e. treaties) call for some type of monitoring. We will review a timeline showing the history of nuclear testing and the more important treaties. We will also describe testing operations, containment, phenomenology, and observations. The Comprehensive Nuclear Test Ban Treaty (CTBT) which has been signed by 179 countries (ratified by 144) established the International Monitoring System global verification regime which employs seismic, infrasound, hydroacoustic and radionuclide monitoring techniques. The CTBT also includes on-site inspection to clarify whether a nuclear explosion has been carried out in violation of the Treaty. The US Department of Energy (DOE) through its National Nuclear Security Agency's Ground-Based Nuclear Explosion Monitoring R&D Program supports research by US National Laboratories, and universities and industry internationally to detect, locate, and identify nuclear detonations. This research program builds on the broad base of monitoring expertise developed over several decades. Annually the DOE and the US Department of Defense jointly solicit monitoring research proposals. Areas of research include: seismic regional characterization and wave propagation, seismic event detection and location, seismic identification and source characterization, hydroacoustic monitoring, radionuclide monitoring, infrasound monitoring, and

  8. EFFECT OF BRONCHODILATORS ON HEART RATE VARIABILITY IN PATIENTS WITH CHRONIC OBSTRUCTIVE PULMONARY DISEASE

    Directory of Open Access Journals (Sweden)

    H. H. Shugushev

    2015-12-01

    Full Text Available Aim. To study effect of long-acting theophylline (Theotard, KRKA and combination of salmeterol and fluticasone (Seretide, GlaxoSmithKline on heart rhythm variability (HRV and number of arrhythmic episodes in patients with chronic obstructive pulmonary disease (COPD.Material and methods. 144 patients with COPD and 35 patients of control group were examined. The analysis of HRV and Holter monitoring were made f on 2th and 14th days.Results. Treatment with both drugs led to increase in power of low- and high frequencies and their ratio (LF/HF, decrease in rate of supraventricular and ventricular arrhythmias. Theophylline therapy raised in a number of single and pair supraventricular extrasystoles. Treatment with combination of salmeterol and fluticasone did not change a number of extrasystoles.Conclusion. Combination of salmeterol and fluticasone is more preferable as a broncholytic therapy for patients with COPD and heart rhythm disorders.

  9. Electrocardiogram Pattern Recognition and Analysis Based on Artificial Neural Networks and Support Vector Machines: A Review

    Directory of Open Access Journals (Sweden)

    Mario Sansone

    2013-01-01

    Full Text Available Computer systems for Electrocardiogram (ECG analysis support the clinician in tedious tasks (e.g., Holter ECG monitored in Intensive Care Units or in prompt detection of dangerous events (e.g., ventricular fibrillation. Together with clinical applications (arrhythmia detection and heart rate variability analysis, ECG is currently being investigated in biometrics (human identification, an emerging area receiving increasing attention. Methodologies for clinical applications can have both differences and similarities with respect to biometrics. This paper reviews methods of ECG processing from a pattern recognition perspective. In particular, we focus on features commonly used for heartbeat classification. Considering the vast literature in the field and the limited space of this review, we dedicated a detailed discussion only to a few classifiers (Artificial Neural Networks and Support Vector Machines because of their popularity; however, other techniques such as Hidden Markov Models and Kalman Filtering will be also mentioned.

  10. Groundwater monitoring of hydraulic fracturing in California: Recommendations for permit-required monitoring

    Science.gov (United States)

    Esser, B. K.; Beller, H. R.; Carroll, S.; Cherry, J. A.; Jackson, R. B.; Jordan, P. D.; Madrid, V.; Morris, J.; Parker, B. L.; Stringfellow, W. T.; Varadharajan, C.; Vengosh, A.

    2015-12-01

    California recently passed legislation mandating dedicated groundwater quality monitoring for new well stimulation operations. The authors provided the State with expert advice on the design of such monitoring networks. Factors that must be considered in designing a new and unique groundwater monitoring program include: Program design: The design of a monitoring program is contingent on its purpose, which can range from detection of individual well leakage to demonstration of regional impact. The regulatory goals for permit-required monitoring conducted by operators on a well-by-well basis will differ from the scientific goals of a regional monitoring program conducted by the State. Vulnerability assessment: Identifying factors that increase the probability of transport of fluids from the hydrocarbon target zone to a protected groundwater zone enables the intensity of permit-required monitoring to be tiered by risk and also enables prioritization of regional monitoring of groundwater basins based on vulnerability. Risk factors include well integrity; proximity to existing wellbores and geologic features; wastewater disposal; vertical separation between the hydrocarbon and groundwater zones; and site-specific hydrogeology. Analyte choice: The choice of chemical analytes in a regulatory monitoring program is guided by the goals of detecting impact, assuring public safety, preventing resource degradation, and minimizing cost. Balancing these goals may be best served by tiered approach in which targeted analysis of specific chemical additives is triggered by significant changes in relevant but more easily analyzed constituents. Such an approach requires characterization of baseline conditions, especially in areas with long histories of oil and gas development. Monitoring technology: Monitoring a deep subsurface process or a long wellbore is more challenging than monitoring a surface industrial source. The requirement for monitoring multiple groundwater aquifers across

  11. A web-based GPS system for displacement monitoring and failure mechanism analysis of reservoir landslide.

    Science.gov (United States)

    Li, Yuanyao; Huang, Jinsong; Jiang, Shui-Hua; Huang, Faming; Chang, Zhilu

    2017-12-07

    It is important to monitor the displacement time series and to explore the failure mechanism of reservoir landslide for early warning. Traditionally, it is a challenge to monitor the landslide displacements real-timely and automatically. Globe Position System (GPS) is considered as the best real-time monitoring technology, however, the accuracies of the landslide displacements monitored by GPS are not assessed effectively. A web-based GPS system is developed to monitor the landslide displacements real-timely and automatically in this study. And the discrete wavelet transform (DWT) is proposed to assess the accuracy of the GPS monitoring displacements. Wangmiao landslide in Three Gorges Reservoir area in China is used as case study. The results show that the web-based GPS system has advantages of high precision, real-time, remote control and automation for landslide monitoring; the Root Mean Square Errors of the monitoring landslide displacements are less than 5 mm. Meanwhile, the results also show that a rapidly falling reservoir water level can trigger the reactivation of Wangmiao landslide. Heavy rainfall is also an important factor, but not a crucial component.

  12. Therapeutic drug monitoring of aminoglycosides in neonates

    NARCIS (Netherlands)

    Touw, Daniël J; Westerman, Elsbeth M; Sprij, Arwen J

    2009-01-01

    The efficacy and toxicity of aminoglycosides show a strong direct positive relationship with blood drug concentrations, therefore, therapy with aminoglycosides in adults is usually guided by therapeutic drug monitoring. Dosing regimens in adults have evolved from multiple daily dosing to

  13. Development of residual gas ionization profile monitor for high intensity proton beams

    CERN Document Server

    Sato, Y; Hirose, E; Ieiri, M; Igarashi, Y; Inaba, S; Katoh, Y; Minakawa, M; Noumi, H; Saitó, M; Suzuki, Y; Takahashi, H; Takasaki, M; Tanaka, K; Toyoda, A; Yamada, Y; Yamanoi, Y; Watanabe, H

    2006-01-01

    Nondestructive beam profile monitor utilizing ionizations of residual gas has been developed for continuous monitoring of 3?0(J-PARC). Knock-on electrons produced in the ionizations of residual gas vacuumed to 1 Pa are collected with a uniform electric field applied between electrodes. Applying a uniform electric field parallel to the electric field is essential to reduce diffusion of electrons crossing over magnetic flux. A prototype monitor has been constructed and installed in EP2-C beam line at KEK 12 GeV proton synchrotron (12 Ge V-PS). The profiles measured with the present monitor agree with the ones measured with the existing destructive profile monitor. The present monitor shows sufficient performances as a candidate of the profile monitor at J-PARC. In the present article, the working principle of the present monitor, the results of test experiments, and further developments are described in detail.

  14. An extended multivariate framework for drought monitoring in Mexico

    Science.gov (United States)

    Real-Rangel, Roberto; Pedrozo-Acuña, Adrián; Breña-Naranjo, Agustín; Alcocer-Yamanaka, Víctor

    2017-04-01

    Around the world, monitoring natural hazards, such as droughts, represents a critical task in risk assessment and management plans. A reliable drought monitoring system allows to identify regions affected by these phenomena so that early response measures can be implemented. In Mexico, this activity is performed using Mexico's Drought Monitor, which is based on a similar methodology as the United States Drought Monitor and the North American Drought Monitor. The main feature of these monitoring systems is the combination of ground-based and remote sensing observations that is ultimately validated by local experts. However, in Mexico in situ records of variables such as precipitation and streamflow are often scarce, or even null, in many regions of the country. Another issue that adds uncertainty in drought monitoring is the arbitrary weight given to each analyzed variable. This study aims at providing an operational framework for drought monitoring in Mexico, based on univariate and multivariate nonparametric standardized indexes proposed in recent studies. Furthermore, the framework has been extended by taking into account the Enhanced Vegetation Index (EVI) for the drought severity assessment. The analyzed variables used for computing the drought indexes are mainly derived from remote sensing (MODIS) and land surface models datasets (NASA MERRA-2). A qualitative evaluation of the results shows that the indexes used are capable of adequately describes the intensity and spatial distribution of past drought documented events.

  15. A conductive grating sensor for online quantitative monitoring of fatigue crack

    Science.gov (United States)

    Li, Peiyuan; Cheng, Li; Yan, Xiaojun; Jiao, Shengbo; Li, Yakun

    2018-05-01

    Online quantitative monitoring of crack damage due to fatigue is a critical challenge for structural health monitoring systems assessing structural safety. To achieve online quantitative monitoring of fatigue crack, a novel conductive grating sensor based on the principle of electrical potential difference is proposed. The sensor consists of equidistant grating channels to monitor the fatigue crack length and conductive bars to provide the circuit path. An online crack monitoring system is established to verify the sensor's capability. The experimental results prove that the sensor is suitable for online quantitative monitoring of fatigue crack. A finite element model for the sensor is also developed to optimize the sensitivity of crack monitoring, which is defined by the rate of sensor resistance change caused by the break of the first grating channel. Analysis of the model shows that the sensor sensitivity can be enhanced by reducing the number of grating channels and increasing their resistance and reducing the resistance of the conductive bar.

  16. Analysis and Implement of Broadcast Program Monitoring Data

    Directory of Open Access Journals (Sweden)

    Song Jin Bao

    2016-01-01

    Full Text Available With the rapid development of the radio and TV industry and the implementation of INT (the integration of telecommunications networks, cable TV networks and the Internet, the contents of programs and advertisements is showing massive, live and interactive trends. In order to meet the security of radio and television, the broadcast of information have to be controlled and administered. In order to master the latest information of public opinion trends through radio and television network, it is necessary research the specific industry applications of broadcast program monitoring. In this paper, the importance of broadcast monitoring in public opinion analysis is firstly analysed. The monitoring radio and television programs broadcast system architecture is proposed combining with the practice, focusing on the technical requirements and implementation process of program broadcast, advertisement broadcast and TV station broadcast monitoring. The more efficient information is generated through statistical analysis, which provides data analysis for radio and television public opinion analysis.

  17. A Case of Turner Syndrome with Multiple Embolic Infarcts

    Directory of Open Access Journals (Sweden)

    Cindy W. Yoon

    2016-09-01

    Full Text Available Only a few cases of Turner syndrome (TS with ischemic stroke have been reported. Various arteriopathies of the cerebral arteries, including fibromuscular dysplasia, congenital hypoplasia, moyamoya syndrome, and premature atherosclerosis have been assumed to be the cause of ischemic stroke in TS. There has been no case report of a TS patient presenting with an embolic stroke pattern without any cerebral arteriopathy. A 28-year-old woman with TS was referred to our hospital because of abnormal brain magnetic resonance imaging (MRI findings. She underwent brain MRI at the referring hospital because she experienced sudden-onset diffuse headache. Diffusion-weighted imaging revealed multiple acute embolic infarcts in different vascular territories. Intracranial and extracranial arterial disease was not detected on cerebral magnetic resonance angiography and carotid sonography. Embolic source workups, including transthoracic and transesophageal echocardiography, Holter monitoring, and transcranial Doppler shunt study, were all negative. Hypercoagulability and vasculitis panels were also negative. Our patient was diagnosed with cryptogenic embolic stroke. This is the first report of a TS patient with an embolic stroke pattern. Our case shows that ischemic stroke in TS could be due to embolism as well as the various cerebral arteriopathies documented in previous reports.

  18. PREDICTIVE FACTORS FOR THE PROGRESSION OF CHRONIC CHAGAS CARDIOMYOPATHY IN PATIENTS WITHOUT LEFT VENTRICULAR DYSFUNCTION

    Directory of Open Access Journals (Sweden)

    Silvana de Araújo SILVA

    2015-04-01

    Full Text Available The identification of predictors for the progression of chronic Chagas cardiomyopathy (CCC is essential to ensure adequate patient management. This study looked into a non-concurrent cohort of 165 CCC patients between 1985 and 2010 for independent predictors for CCC progression. The outcomes were worsening of the CCC scores and the onset of left ventricular dysfunction assessed by means of echo-Doppler cardiography. Patients were analyzed for social, demographic, epidemiologic, clinical and workup-related variables. A descriptive analysis was conducted, followed by survival curves based on univariate (Kaplan-Meier and Cox’s univariate model and multivariate (Cox regression model analysis. Patients were followed from two to 20 years (mean: 8.2. Their mean age was 44.8 years (20-77. Comparing both iterations of the study, in the second there was a statistically significant increase in the PR interval and in the QRS duration, despite a reduction in heart rates (Wilcoxon < 0.01. The predictors for CCC progression in the final regression model were male gender (HR = 2.81, Holter monitoring showing pauses equal to or greater than two seconds (HR = 3.02 increased cardiothoracic ratio (HR = 7.87 and time of use of digitalis (HR = 1.41. Patients with multiple predictive factors require stricter follow-up and treatment.

  19. COMPARATIVE EFFECTS OF MONOTHERAPY WITH MAGNESIUM AND COMBINED THERAPY WITH MAGNESIUM AND Β-BLOCKER ON PRIMARY MITRAL VALVE PROLAPSE WITH HEART RHYTHM DISORDERS

    Directory of Open Access Journals (Sweden)

    E. G. Nurtdinova

    2007-01-01

    Full Text Available Aim. To compare effects of monotherapy with magnesium and combined therapy with magnesium and β-blocker on primary mitral valve prolapse (MVP with heart rhythm disorders.Material and methods. 71 patients with primary MVP 1-2 degree and heart rhythm disorders were involved in the study. The patients were split into three groups. Group I (25 persons received monotherapy with magnesium orotate at a dose of 1-3 g per day; group II (28 persons received combined therapy with magnesium orotate and betaxolol. The control group (18 persons received no therapy. Initially and after 12 weeks of observation all the patients underwent electrocardiography (ECG, ECG-Holter monitoring, echocardiography and autonomic balance assessment by A.M. Vein’s questionnaire.Results. In 12 weeks of treatment groups I and II showed positive dynamics in the MVP manifestations, including significant reduction in severity of the autonomic dysfunction syndrome, ECG positive dynamics, antiarrhythmic effect, decrease in the degree of prolapse, diminution of mitral regurgitation and left auricle volumes. More substantial hemodynamic effects were found in the group of patients who received combination therapy.Conclusion. Combined therapy has proven advantages in comparison with magnesium monotherapy in terms of daily quantity of extrasystoles, reduction in heart rate, decrease in autonomic disfunction and normalization of intracardiac hemodynamics.

  20. COMPARATIVE EFFECTS OF MONOTHERAPY WITH MAGNESIUM AND COMBINED THERAPY WITH MAGNESIUM AND Β-BLOCKER ON PRIMARY MITRAL VALVE PROLAPSE WITH HEART RHYTHM DISORDERS

    Directory of Open Access Journals (Sweden)

    E. G. Nurtdinova

    2015-12-01

    Full Text Available Aim. To compare effects of monotherapy with magnesium and combined therapy with magnesium and β-blocker on primary mitral valve prolapse (MVP with heart rhythm disorders.Material and methods. 71 patients with primary MVP 1-2 degree and heart rhythm disorders were involved in the study. The patients were split into three groups. Group I (25 persons received monotherapy with magnesium orotate at a dose of 1-3 g per day; group II (28 persons received combined therapy with magnesium orotate and betaxolol. The control group (18 persons received no therapy. Initially and after 12 weeks of observation all the patients underwent electrocardiography (ECG, ECG-Holter monitoring, echocardiography and autonomic balance assessment by A.M. Vein’s questionnaire.Results. In 12 weeks of treatment groups I and II showed positive dynamics in the MVP manifestations, including significant reduction in severity of the autonomic dysfunction syndrome, ECG positive dynamics, antiarrhythmic effect, decrease in the degree of prolapse, diminution of mitral regurgitation and left auricle volumes. More substantial hemodynamic effects were found in the group of patients who received combination therapy.Conclusion. Combined therapy has proven advantages in comparison with magnesium monotherapy in terms of daily quantity of extrasystoles, reduction in heart rate, decrease in autonomic disfunction and normalization of intracardiac hemodynamics.

  1. A Psychological Factor Affecting a Cardiac Condition in a Psychotherapist

    Directory of Open Access Journals (Sweden)

    R Waxman

    2009-03-01

    Full Text Available It has been established that intense emotions can affect the development and course of cardiac arrhythmias. This study sought to convey that a lack of expression of emotion can also have an effect on arrhythmias. A psychotherapist with Idiopathic Ventricular Fibrillation and an Implantable Cardioverter Defibrillator measured his rate of Premature Ventricular Contractions using a Holter monitor during three separate six-week periods and in three domains: A work days vs. off days, B a 27 hour work week vs. 22 hour work week, and C in 5 different modalities including 1 Meeting with department head 2 Individual psychotherapy with patients 3 Group therapy with patients 4 Supervision of residents 5 Personal psychoanalysis. The results showed more than a 3-fold increase of arrhythmogenic activity during the 27-hour work week vs. 22 and a 5-fold increase in arrhythmogenic activity on work days compared to days off. Department Head meetings were found to be most arrhythmogenic and personal psychoanalysis was least. The data suggest that the psychiatrist’s lack of emotional expression in his clinical work has been demonstrated to markedly worsen his arrhythmia. The results also point to the potential ameliorating effects of the therapist’s own psychotherapy.

  2. Qt interval prolongation and ventricular arrhythmias in patients with chronic heart failure

    International Nuclear Information System (INIS)

    Sarwar, M.; Majeed, S.M.I.; Khan, M.A.; Majeed, S.M.

    2014-01-01

    To determine the association of QTc interval prolongation with ventricular arrhythmias in patients with chronic heart failure. Study Design: Descriptive study. Place and Duration of Study: This study was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases, Rawalpindi, Pakistan from April 2013 to August 2013. Patients and Methods: Fifty three heart failure patients were monitored for 48 hours using ambulatory holter electrocardiography recorders. Digital ECG data was analyzed for QTc interval along with frequency and severity of arrhythmias. Association of prolonged QTc interval with ventricular arrhythmias and severity of arrhythmias was analyzed. Results: Cardiac arrhythmias were observed in 79.2% patients. QT analysis revealed that 69.8% patients had prolonged QTc interval, 86.4% patients with prolonged QTc had ventricular arrhythmias. Of these 66% patients were found to have severe ventricular arrhythmias. Comparison of mean QTc interval of our study population with a reference value showed significantly higher QTc interval of our study group than the test value. Conclusion: Arrhythmia frequency and severity significantly increases with an increase in QTc interval in heart failure demonstrating association of prolonged QTc interval with high risk of severe ventricular arrhythmias and sudden cardiac death in chronic heart failure. (author)

  3. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  4. A simple condition monitoring model for a direct monitoring process

    NARCIS (Netherlands)

    Christer, A.H.; Wang, Wenbin

    1995-01-01

    This paper addresses the problem of condition monitoring of a component which has available a measure of condition called wear. Wear accumulates over time and monitoring inspections are performed at chosen times to monitor and measure the cumulative wear. If past measurements of wear are available

  5. Multi-controller based 29 channel whole body portal monitor

    International Nuclear Information System (INIS)

    Dheeraj Reddy, J.; Narender Reddy, J.

    2004-01-01

    Portal Monitors are an essential part of personnel monitoring programme in any Nuclear Power Plant or Radiochemical/Reprocessing Plant. Compared to conventional Portal Monitors, whole-body Portals are preferred, for effective monitoring of entire body of the person being monitored for radioactive contamination. This is achieved by effectively distributing a large number of detectors on front/back of the person being monitored. The entry and exit for such Portals is usually side ways. The electronic system, designed essentially consists of powerful compact electronic circuits, comprising of three micro-controllers, a host of (32) 12C serial counters, other serial ADCs, DACs etc., apart from pulse processing, HV and LV circuits. Built-in embedded code has powerful fault diagnostics routines to show up failures in detector / detector electronics, HV, LV and other circuits apart from indicating contamination status, through visual and aural indications such as MIMIC, visual LCD display and individual channel counts etc. The Portal structural design consists of four individual SS members integrated, lead shielding assemblies (inside), on hinged support frames facilitate ease of assembling and dismantling of the structure. The detector arrangement is so arranged to have optimal uniform spread out, so as to record contamination of the whole body of the person being monitored. (author)

  6. Delta count-rate monitoring system

    International Nuclear Information System (INIS)

    Van Etten, D.; Olsen, W.A.

    1985-01-01

    A need for a more effective way to rapidly search for gamma-ray contamination over large areas led to the design and construction of a very sensitive gamma detection system. The delta count-rate monitoring system was installed in a four-wheel-drive van instrumented for environmental surveillance and accident response. The system consists of four main sections: (1) two scintillation detectors, (2) high-voltage power supply amplifier and single-channel analyzer, (3) delta count-rate monitor, and (4) count-rate meter and recorder. The van's 6.5-kW generator powers the standard nuclear instrument modular design system. The two detectors are mounted in the rear corners of the van and can be run singly or jointly. A solid-state bar-graph count-rate meter mounted on the dashboard can be read easily by both the driver and passenger. A solid-state strip chart recorder shows trends and provides a permanent record of the data. An audible alarm is sounded at the delta monitor and at the dashboard count-rate meter if a detected radiation level exceeds the set background level by a predetermined amount

  7. Environmental monitoring report: Sandia Laboratories, 1976

    International Nuclear Information System (INIS)

    Simmons, T.N.

    1977-04-01

    Water and vegetation are monitored to determine Sandia Laboratories impact on the surrounding environment. Nonradioactive pollutants released are reported. Radioactive effluents are also reported and their person-rem contribution to the Albuquerque population is calculated. The environmental monitoring for calendar year 1976 shows that concentrations of radioactive materials in the Albuquerque area are typical of natural background for the area. An exception is a single onsite location where slightly abnormal uranium concentrations are expected. An estimated 0.044 person-rem Albuquerque area (80 km radius) population dose commitment results from calculated Sandia Laboratories releases. Over the same area 57,000 person-rem is accumulated from natural background. There were no measurable offsite radioactive effluent releases in CY 1976

  8. The development of web monitoring digital area monitor

    International Nuclear Information System (INIS)

    Jung, Hoon-Jin; Lee, Jun-Hee; Namkoong, Phil; Lee, Dong-Hoon; Lee, Su-Hong; Kim, We-Su

    2005-01-01

    As CCTV and radiation area monitor have been used separately to date, there have existed inconveniences in managing the view images and radiation dose rates from them. Thus we became to develop the web monitoring digital area monitor which incorporated the existing two factors, CCTV and radiation area monitor, into one. As incorporated with digitalisation, this device will usually become linked with PC, so that the view image and radiation dose rate can be concurrently identified in convenience. These measured figures automatically become data-based on PC by SW program, and become displayed in various format. Moreover, they can be monitored in remote and real time basis in the internet environment. Its local unit uses the cost-effective GM tube and CMOS image sensor, and has the small LCD which directly indicates the measured dose rate. The image sensor is designed to be operated with pan and tilt motion, thus can eliminate the dead view zone. It is thought that the developed device at this time could make the radiation safety management of each work field be done with low cost-high efficiency manner, making role of the CCTV inspection system

  9. The development of web monitoring digital area monitor

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hoon-Jin; Lee, Jun-Hee; Namkoong, Phil; Lee, Dong-Hoon; Lee, Su-Hong; Kim, We-Su [Iljin Radiation Engineering Co., Seoul (Korea, Republic of)

    2005-11-15

    As CCTV and radiation area monitor have been used separately to date, there have existed inconveniences in managing the view images and radiation dose rates from them. Thus we became to develop the web monitoring digital area monitor which incorporated the existing two factors, CCTV and radiation area monitor, into one. As incorporated with digitalisation, this device will usually become linked with PC, so that the view image and radiation dose rate can be concurrently identified in convenience. These measured figures automatically become data-based on PC by SW program, and become displayed in various format. Moreover, they can be monitored in remote and real time basis in the internet environment. Its local unit uses the cost-effective GM tube and CMOS image sensor, and has the small LCD which directly indicates the measured dose rate. The image sensor is designed to be operated with pan and tilt motion, thus can eliminate the dead view zone. It is thought that the developed device at this time could make the radiation safety management of each work field be done with low cost-high efficiency manner, making role of the CCTV inspection system.

  10. Establishing a mobile automatic monitoring station for emergency response

    International Nuclear Information System (INIS)

    Fang, Hsin-Fa

    2008-01-01

    Full text: A radiological/nuclear emergency event may cause environmental contamination. The emergency response works always need to plan an environmental survey programme incorporating the assessment results to see what is happening. The places where are assessed to have the highest radioactive contamination/radiation dose will catch more concern and need continuous monitoring. It will cause unnecessary dangers and dose to command that personnel conduct surveying in such places when the radiological/nuclear accident become more severe. A mobile automatic monitoring station has been established for emergency response by INER (Institute of Nuclear Energy Research) to solve the problem practically. The monitoring station involves a HPIC to monitor radiation dose, an anemometer to monitor wind speed and direction, a GPS to get position data, a GPRS/3G communication module to send monitoring and positioning data to the monitoring centre where can show the monitoring result directly on a map shown on the computer. These instruments are integrated in a trailer easy to be towed to the place need to be monitored. The electric power of the station is supplied by s a solar power energy system. It can supply the station working at least 10 days without extra electric power supply designed based on the expected time length of a nuclear power plant event. The HPIC is very sensitive and stable that can discriminate a 10 nSv/hr increasing of dose rate with the monitoring time period every ten seconds. Where the radiological dispersion device events happened is not predictable, it is difficult to get suitable wind monitoring data to assess the result of radiological dispersion device events. The anemometer added on the station can provide the real time wind monitoring data to help assessment works. (author)

  11. Microcalorimetric monitoring of grape withering

    International Nuclear Information System (INIS)

    Morozova, Ksenia; Romano, Andrea; Lonardi, Francesco; Ferrarini, Roberto; Biasioli, Franco; Scampicchio, Matteo

    2016-01-01

    Highlights: • Microcalorimetry was applied to monitor grape withering. • Heat flow was used to estimate rate of respiration. • Calorimetry was coupled with analysis of volatile compounds. • Data analysis showed three steps of withering. - Abstract: This work aimed at monitoring the metabolic activity of grapes during withering by microcalorimetry. Samples of Corvina grapes, a cultivar used in the production of Amarone wine, were dehydrated for about 120 days at an industrial scale plants (fruttaia). Single berries, sampled in the course of the withering process, were closed in ampoules and maintained at constant temperature. As biochemical events (i.e. berry respiration, microbial growth, etc.) are always accompanied by the production of heat (q), the heat-flow (dq/dt) emitted by berries enclosed in the ampoules was used to monitor their metabolic activity during withering, i.e. respiration. For each sampling time, the heat rate production of the berries at 298 K was monitored till a steady state signal was achieved (within 60 h). Such heat flow value was used as marker during the entire withering process (120 days). Its trend allowed to characterize the changes in the metabolic activity of the grape berries along the withering process. To understand the origin of such changes, the emission of volatile organic compounds (VOCs) were also measured by proton transfer mass spectrometry (PTR-MS). The use of microcalorimetry associated with the analysis of specific VOCs fragments offered a valuable information to describe the withering process.

  12. Microcalorimetric monitoring of grape withering

    Energy Technology Data Exchange (ETDEWEB)

    Morozova, Ksenia; Romano, Andrea [Free University of Bozen-Bolzano, Faculty of Science and Technology, piazza Università 1, 39100 Bolzano (Italy); Lonardi, Francesco; Ferrarini, Roberto [PerfectWine s.r.l., Via della Pieve 70, 37029 S. Floriano (Italy); Biasioli, Franco [Department of Food Quality and Nutrition, Research and Innovation Centre, Fondazione Edmund Mach (FEM), Via E. Mach 1, 38010 San Michele all’Adige (Italy); Scampicchio, Matteo, E-mail: matteo.scampicchio@unibz.it [Free University of Bozen-Bolzano, Faculty of Science and Technology, piazza Università 1, 39100 Bolzano (Italy)

    2016-04-20

    Highlights: • Microcalorimetry was applied to monitor grape withering. • Heat flow was used to estimate rate of respiration. • Calorimetry was coupled with analysis of volatile compounds. • Data analysis showed three steps of withering. - Abstract: This work aimed at monitoring the metabolic activity of grapes during withering by microcalorimetry. Samples of Corvina grapes, a cultivar used in the production of Amarone wine, were dehydrated for about 120 days at an industrial scale plants (fruttaia). Single berries, sampled in the course of the withering process, were closed in ampoules and maintained at constant temperature. As biochemical events (i.e. berry respiration, microbial growth, etc.) are always accompanied by the production of heat (q), the heat-flow (dq/dt) emitted by berries enclosed in the ampoules was used to monitor their metabolic activity during withering, i.e. respiration. For each sampling time, the heat rate production of the berries at 298 K was monitored till a steady state signal was achieved (within 60 h). Such heat flow value was used as marker during the entire withering process (120 days). Its trend allowed to characterize the changes in the metabolic activity of the grape berries along the withering process. To understand the origin of such changes, the emission of volatile organic compounds (VOCs) were also measured by proton transfer mass spectrometry (PTR-MS). The use of microcalorimetry associated with the analysis of specific VOCs fragments offered a valuable information to describe the withering process.

  13. Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

    Science.gov (United States)

    Shannon, A. V.

    1977-01-01

    The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

  14. Wireless air monitoring network with new AMIZ-2004G dust monitors

    International Nuclear Information System (INIS)

    Jakowiuk, A.; Machaj, B.; Pienkos, P.; Swistowski, E.

    2006-01-01

    The principle of operation of the dust monitors is based on determination of dust mass deposited on air filters from known volumes of air samples. The dust mass is determined from radiation attenuation of a Pm-147 beta source. MIZA and AMIZ monitors produced in the Institute of Nuclear Chemistry and Technology, Warsaw (Poland) additionally measure relative humidity, atmospheric pressure and temperature of the air. In case the measurements are made in a few different places, direct collection of the results requires that personnel of the environment protection units has to go frequently to the monitors and collect the data. To improve the data transmission, a new version of the AMIZ-2004G monitor was developed which is equipped with a GSM modem enabling communication with a central computer. Thanks to the new construction not only a remote wireless communication with AMIZ is possible, but also a monitoring network containing a higher number of dust monitors can be made. The measuring data from all the monitors in the network can now be collected in one central computer equipped with the GSM modem and a proper acquisition program. In 2005, two such monitoring networks were put into operation

  15. Atriofascicular Mahaim with Ebstein anomaly: A case report

    Directory of Open Access Journals (Sweden)

    Kazushi Ueshima, MD

    2017-10-01

    Full Text Available We report a case of a 7-year-old girl with atriofascicular Mahaim (AFM pathway concomitant with Ebstein's anomaly. The QRS wave showed left bundle branch block pattern on electrocardiogram. Holter electrocardiogram showed prolongation of the PR interval and QRS morphological change during sinus tachycardia. An electrophysiological study demonstrated that the distal His potential appeared earlier than the proximal His potential, which suggested retrograde His conduction toward the atrioventricular node. Conduction from the Mahaim fiber to the His bundle was faster than that from the atrioventricular node towards the His bundle. The findings of this important case allowed a differential diagnosis between AFM and Wolff-Parkinson-White (WPW syndrome.

  16. Remote Monitoring Transparency Program

    International Nuclear Information System (INIS)

    Sukhoruchkin, V.K.; Shmelev, V.M.; Roumiantsev, A.N.

    1996-01-01

    The objective of the Remote Monitoring Transparency Program is to evaluate and demonstrate the use of remote monitoring technologies to advance nonproliferation and transparency efforts that are currently being developed by Russia and the United States without compromising the national security to the participating parties. Under a lab-to-lab transparency contract between Sandia National Laboratories (SNL) and the Kurchatov Institute (KI RRC), the Kurchatov Institute will analyze technical and procedural aspects of the application of remote monitoring as a transparency measure to monitor inventories of direct- use HEU and plutonium (e.g., material recovered from dismantled nuclear weapons). A goal of this program is to assist a broad range of political and technical experts in learning more about remote monitoring technologies that could be used to implement nonproliferation, arms control, and other security and confidence building measures. Specifically, this program will: (1) begin integrating Russian technologies into remote monitoring systems; (2) develop remote monitoring procedures that will assist in the application of remote monitoring techniques to monitor inventories of HEU and Pu from dismantled nuclear weapons; and (3) conduct a workshop to review remote monitoring fundamentals, demonstrate an integrated US/Russian remote monitoring system, and discuss the impacts that remote monitoring will have on the national security of participating countries

  17. Implementing and Innovating Marine Monitoring Approaches for Assessing Marine Environmental Status

    KAUST Repository

    Danovaro, Roberto; Carugati, Laura; Berzano, Marco; Cahill, Abigail E.; Carvalho, Susana; Chenuil, Anne; Corinaldesi, Cinzia; Cristina, Sonia; David, Romain; Dell'Anno, Antonio; Dzhembekova, Nina; Garcé s, Esther; Gasol, Joseph M.; Goela, Priscila; Fé ral, Jean-Pierre; Ferrera, Isabel; Forster, Rodney M.; Kurekin, Andrey A.; Rastelli, Eugenio; Marinova, Veselka; Miller, Peter I.; Moncheva, Snejana; Newton, Alice; Pearman, John K.; Pitois, Sophie G.; Reñ é , Albert; Rodrí guez-Ezpeleta, Naiara; Saggiomo, Vincenzo; Simis, Stefan G. H.; Stefanova, Kremena; Wilson, Christian; Lo Martire, Marco; Greco, Silvestro; Cochrane, Sabine K. J.; Mangoni, Olga; Borja, Angel

    2016-01-01

    Marine environmental monitoring has tended to focus on site-specific methods of investigation. These traditional methods have low spatial and temporal resolution and are relatively labor intensive per unit area/time that they cover. To implement the Marine Strategy Framework Directive (MSFD), European Member States are required to improve marine monitoring and design monitoring networks. This can be achieved by developing and testing innovative and cost-effective monitoring systems, as well as indicators of environmental status. Here, we present several recently developed methodologies and technologies to improve marine biodiversity indicators and monitoring methods. The innovative tools are discussed concerning the technologies presently utilized as well as the advantages and disadvantages of their use in routine monitoring. In particular, the present analysis focuses on: (i) molecular approaches, including microarray, Real Time quantitative PCR (qPCR), and metagenetic (metabarcoding) tools; (ii) optical (remote) sensing and acoustic methods; and (iii) in situ monitoring instruments. We also discuss their applications in marine monitoring within the MSFD through the analysis of case studies in order to evaluate their potential utilization in future routine marine monitoring. We show that these recently-developed technologies can present clear advantages in accuracy, efficiency and cost.

  18. Implementing and Innovating Marine Monitoring Approaches for Assessing Marine Environmental Status

    KAUST Repository

    Danovaro, Roberto

    2016-11-23

    Marine environmental monitoring has tended to focus on site-specific methods of investigation. These traditional methods have low spatial and temporal resolution and are relatively labor intensive per unit area/time that they cover. To implement the Marine Strategy Framework Directive (MSFD), European Member States are required to improve marine monitoring and design monitoring networks. This can be achieved by developing and testing innovative and cost-effective monitoring systems, as well as indicators of environmental status. Here, we present several recently developed methodologies and technologies to improve marine biodiversity indicators and monitoring methods. The innovative tools are discussed concerning the technologies presently utilized as well as the advantages and disadvantages of their use in routine monitoring. In particular, the present analysis focuses on: (i) molecular approaches, including microarray, Real Time quantitative PCR (qPCR), and metagenetic (metabarcoding) tools; (ii) optical (remote) sensing and acoustic methods; and (iii) in situ monitoring instruments. We also discuss their applications in marine monitoring within the MSFD through the analysis of case studies in order to evaluate their potential utilization in future routine marine monitoring. We show that these recently-developed technologies can present clear advantages in accuracy, efficiency and cost.

  19. Cardiorespiratory screening in elite endurance sports athletes: the Quebec study.

    Science.gov (United States)

    Turmel, Julie; Poirier, Paul; Bougault, Valérie; Blouin, Evelyne; Belzile, Mireille; Boulet, Louis-Philippe

    2012-09-01

    Cardiorespiratory disorders are common in athletes. However, these conditions are often underdiagnosed, which potentially results in impaired performance and increased health risks. The aim of this study was to evaluate, in a research setting, the prevalence of cardiorespiratory disorders in athletes in order to determine the potential value of a screening program. One hundred thirty-three athletes were studied. Each subject underwent a physical examination. A eucapnic voluntary hyperventilation (EVH) test and a methacholine inhalation test were performed to confirm the diagnosis of asthma. A cardiovascular evaluation was also performed, including maximal exercise test with electrocardiogram, 24-hour ambulatory blood pressure monitoring, 24-hour Holter monitoring, and blood sampling. Seventy-four (56%) athletes had airway hyperresponsiveness to EVH or the methacholine inhalation test. Among those with airway hyperresponsiveness, 45 (61%) athletes were only hyperresponsive to EVH, and 10 (14%) were only hyperresponsive to the methacholine inhalation test (using the criteria of a PC20 ≤ 4 mg/mL). Thirty-two (24%) athletes had a known diagnosis of asthma, while 34 (26%) athletes received a new asthma diagnosis. Ninety-seven (73%) athletes were sensitized to common airborne allergens. Forty-seven (35%) athletes completed the cardiovascular evaluation. Three (6%) and 7 (15%) athletes had a previous or new diagnosis of cardiovascular disease, respectively. Resting systemic hypertension was documented in 2 (4%) athletes and exaggerated blood pressure response to exercise was found in 12 (26%) athletes. This cardiorespiratory screening data set in athletes showed a high prevalence of exercise-induced asthma and exercise hypertension, which in many cases were not previously diagnosed.

  20. Frequent premature ventricular contractions in an orbital spaceflight participant.

    Science.gov (United States)

    Jennings, Richard T; Stepanek, Jan P; Scott, Luis R; Voronkov, Yury I

    2010-06-01

    Commercial spaceflight participants on orbital flights typically are older than career astronauts and they often have medical conditions that have not been studied at high g or in microgravity. This is a case report of a 56-yr-old orbital spaceflight participant with essential tremor and frequent premature ventricular contractions that occurred at rates up to 7000 per day. Before training and spaceflight, he was required to complete extensive clinical investigations to demonstrate normal cardiac structures and the absence of cardiac pathology. The evaluation included signal averaged ECG, transthoracic stress echocardiography, exercise tolerance tests, electrophysiological studies, cardiac MRI, electron beam CT, Holter monitoring, and overnight oximetry. While no cardiac pathology was demonstrated, the Russian medical team required that the PVCs be treated prior to training and spaceflight. For the initial flight, a selective beta-1 receptor beta blocker was used and for the second a calcium channel blocker was used in combination with a nonselective beta blocker for tremor control. Analogue environment testing assured that this combination of medications was compatible. The spaceflight participant's PVCs were incompletely suppressed with a low-dose selective beta-1 blocker, but were well suppressed by a calcium channel blocker. He tolerated in-flight periodic use of a nonselective beta blocker in combination with a calcium channel blocker. In-flight ECG and blood pressure monitoring results were normal, and an ECG obtained midmission and on landing day showed successful PVC suppression. He did not have any cardiac difficulty with launch, on-orbit operations, entry, or recovery

  1. Spatial sensitivity and penetration depth of three cerebral oxygenation monitors

    Science.gov (United States)

    Gunadi, Sonny; Leung, Terence S.; Elwell, Clare E.; Tachtsidis, Ilias

    2014-01-01

    The spatial sensitivities of NIRO-100, ISS Oximeter and TRS-20 cerebral oxygenation monitors are mapped using the local perturbation method to inform on their penetration depths and susceptibilities to superficial contaminations. The results show that TRS-20 has the deepest mean penetration depth and is less sensitive than the other monitors to a localized absorption change in the superficial layer. However, an integration time of more than five seconds is required by the TRS-20 to achieve an acceptable level of signal-to-noise ratio, which is the poorest amongst the monitors. With the exception of NIRO-100 continuous wave method, the monitors are not significantly responsive to layer-wide absorption change that occurs in the superficial layer. PMID:25401006

  2. Influence of tilt training on activation of the autonomic nervous system in patients with vasovagal syncope.

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Halawa, Bogumił; Mazurek, Walentyna

    2006-04-01

    Tilt training is a new treatment for vasovagal syncope. Its therapeutic efficacy is thought to be the result of the desensitization of cardiopulmonary receptors, but it could be the influence of the tilt training on the activation of the autonomic nervous system as well. The study group consisted of 24 vasovagal patients (17 women and 7 men) aged 32.5 +/- 11.8 years. The diagnostic head-up tilt test was performed according to the Italian protocol with nitroglycerin if necessary. The monitoring head-up tilt test was performed according to the Westminster protocol without provocation, after 1 to 3 months of tilt training. Holter ECG recordings for HRV parameters (time and frequency domain) were obtained from selected 2-min intervals before, during and after the diagnostic and monitoring tilt test. The diagnostic test was positive in the passive phase in 6 and after provocation in 18 patients. During the training period no syncope occurred. Analysing the HRV parameters we demonstrated the following findings: I. mRR decreases immediately after assumption of a vertical position in both tests (diagnostic and monitoring) but in the diagnostic test its further decrease occurs earlier than in the monitoring test; 2. the absolute power of the HF component is greater in the early phase of tilt after tilt training than in the corresponding period in the diagnostic test. After a longer period of tilt training the activation of the sympathetic nervous system in response to the erect position is diminished.

  3. Monitor inspection device

    International Nuclear Information System (INIS)

    Ueshima, Yoshinobu.

    1995-01-01

    The device of the present invention reliably conducts monitoring by radiation monitors in a nuclear power plant thereby contributing to save the number of radiation operators and reduction of radiation exposure. Namely, radiation monitors continuously measure a plurality of γ-ray levels. A branched simultaneously counting circuit receives these signals. The output of the branched simultaneously counting circuit is inputted to a differentiation means. The differentiation means calculates a variation coefficient for each of the radiation monitoring values, namely, equivalent dose rates, and records and monitors change with time of the equivalent dose rates. With such procedures, the results of the monitoring of γ-ray levels can be judged objectively corresponding to the increase of the equivalent dose rates. As a result, the number of radiation operators can be saves and radiation exposure of the radiation operators can be reduced. (I.S.)

  4. Optimizing Groundwater Monitoring Networks Using Integrated Statistical and Geostatistical Approaches

    Directory of Open Access Journals (Sweden)

    Jay Krishna Thakur

    2015-08-01

    Full Text Available The aim of this work is to investigate new approaches using methods based on statistics and geo-statistics for spatio-temporal optimization of groundwater monitoring networks. The formulated and integrated methods were tested with the groundwater quality data set of Bitterfeld/Wolfen, Germany. Spatially, the monitoring network was optimized using geo-statistical methods. Temporal optimization of the monitoring network was carried out using Sen’s method (1968. For geostatistical network optimization, a geostatistical spatio-temporal algorithm was used to identify redundant wells in 2- and 2.5-D Quaternary and Tertiary aquifers. Influences of interpolation block width, dimension, contaminant association, groundwater flow direction and aquifer homogeneity on statistical and geostatistical methods for monitoring network optimization were analysed. The integrated approach shows 37% and 28% redundancies in the monitoring network in Quaternary aquifer and Tertiary aquifer respectively. The geostatistical method also recommends 41 and 22 new monitoring wells in the Quaternary and Tertiary aquifers respectively. In temporal optimization, an overall optimized sampling interval was recommended in terms of lower quartile (238 days, median quartile (317 days and upper quartile (401 days in the research area of Bitterfeld/Wolfen. Demonstrated methods for improving groundwater monitoring network can be used in real monitoring network optimization with due consideration given to influencing factors.

  5. Electrical stimulation of the dorsolateral prefrontal cortex improves memory monitoring.

    Science.gov (United States)

    Chua, Elizabeth F; Ahmed, Rifat

    2016-05-01

    The ability to accurately monitor one's own memory is an important feature of normal memory function. Converging evidence from neuroimaging and lesion studies have implicated the dorsolateral prefrontal cortex (DLPFC) in memory monitoring. Here we used high definition transcranial direct stimulation (HD-tDCS), a non-invasive form of brain stimulation, to test whether the DLPFC has a causal role in memory monitoring, and the nature of that role. We used a metamemory monitoring task, in which participants first attempted to recall the answer to a general knowledge question, then gave a feeling-of-knowing (FOK) judgment, followed by a forced choice recognition task. When participants received DLPFC stimulation, their feeling-of-knowing judgments were better predictors of memory performance, i.e., they had better memory monitoring accuracy, compared to stimulation of a control site, the anterior temporal lobe (ATL). Effects of DLPFC stimulation were specific to monitoring accuracy, as there was no significant increase in memory performance, and if anything, there was poorer memory performance with DLPFC stimulation. Thus we have demonstrated a causal role for the DLPFC in memory monitoring, and showed that electrically stimulating the left DLPFC led people to more accurately monitor and judge their own memory. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Monitoring feeding behaviour of dairy cows using accelerometers

    Directory of Open Access Journals (Sweden)

    Gabriele Mattachini

    2016-03-01

    Full Text Available Monitoring cow behaviour has become increasingly important in understanding the nutrition, production, management of the well being, and overall health of dairy cows. Methods of assessing behavioural activity have changed in recent years, favouring automatic recording techniques. Traditional methods to measure behaviour, such as direct observation or time-lapse video, are labour-intensive and time-consuming. Automated recording devices have become increasingly common to measure behaviour accurately. Thus, the development of automated monitoring systems that can continuously and accurately quantify feeding behaviour are required for efficient monitoring and control of modern and automated dairy farms. The aim of this study was to evaluate the possible use of a 3D accelerometer to record feeding behaviour of dairy cows. Feeding behaviour (feeding time and number of visits to the manger of 12 lactating dairy cows was recorded for approximately 3 h with 3D-accelerometer data loggers (HOBO Pendant G logger. The sensors were positioned in the high part of the neck to monitor head movements. Behaviour was simultaneously recorded using visual observation as a reference. Linear regression analysis between the measurement methods showed that the recorded feeding time (R2=0.90, n=12, P<0.001 was closely related to visual observations. In contrast, the number of visits was inadequately recorded by the 3D-accelerometer, showing a poor relationship with visual observations (R2=0.31, n=12, P<0.06. Results suggest that the use of accelerometer sensors can be a reliable and suitable technology for monitoring feeding behaviour of individual dairy cows in free stall housing. However, further research is necessary to develop an appropriate device able to detect and recognise the movements connected with the head movement during feeding. Such a device could be part of an automatic livestock management tool for the efficient monitoring and control of comfort and

  7. Diode readout electronics for beam intensity and position monitors for FELs

    International Nuclear Information System (INIS)

    Herrmann, S; Hart, P; Freytag, M; Pines, J; Weaver, M; Sapozhnikov, L; Nelson, S; Koglin, J; Carini, G A; Tomada, A; Haller, G

    2014-01-01

    LCLS uses Intensity-Position Monitors (IPM) to measure intensity and position of the FEL x-ray pulses. The primary beam passes through a silicon nitride film and four diodes, arranged in quadrants, detect the backscattered x-ray photons. The position is derived from the relative intensity of the four diodes, while the sum provides beam intensity information. In contrast to traditional synchrotron beam monitors, where diodes measure a DC current signal, the LCLS beam monitors have to cope with the pulsed nature of the FEL, which requires a large single shot dynamic range. A key component of these beam monitors is the readout electronics. The first generation of beam monitors showed some limitations. A new scheme with upgraded electronics, firmware and software was implemented resulting in a more robust and reliable measuring tool.

  8. Network Monitoring as a Streaming Analytics Problem

    KAUST Repository

    Gupta, Arpit

    2016-11-02

    Programmable switches make it easier to perform flexible network monitoring queries at line rate, and scalable stream processors make it possible to fuse data streams to answer more sophisticated queries about the network in real-time. Unfortunately, processing such network monitoring queries at high traffic rates requires both the switches and the stream processors to filter the traffic iteratively and adaptively so as to extract only that traffic that is of interest to the query at hand. Others have network monitoring in the context of streaming; yet, previous work has not closed the loop in a way that allows network operators to perform streaming analytics for network monitoring applications at scale. To achieve this objective, Sonata allows operators to express a network monitoring query by considering each packet as a tuple and efficiently partitioning each query between the switches and the stream processor through iterative refinement. Sonata extracts only the traffic that pertains to each query, ensuring that the stream processor can scale traffic rates of several terabits per second. We show with a simple example query involving DNS reflection attacks and traffic traces from one of the world\\'s largest IXPs that Sonata can capture 95% of all traffic pertaining to the query, while reducing the overall data rate by a factor of about 400 and the number of required counters by four orders of magnitude. Copyright 2016 ACM.

  9. Monitoring and modelling of biosphere/atmosphere exchange of gases and aerosols in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Erisman, Jan Willem [Energy Research Centre of the Netherlands (ECN), P.O. Box 1, 1755 ZG Petten (Netherlands)]. E-mail: erisman@ecn.nl; Vermeulen, Alex [Energy Research Centre of the Netherlands (ECN), P.O. Box 1, 1755 ZG Petten (Netherlands); Hensen, Arjan [Energy Research Centre of the Netherlands (ECN), P.O. Box 1, 1755 ZG Petten (Netherlands); Flechard, Chris [Energy Research Centre of the Netherlands (ECN), P.O. Box 1, 1755 ZG Petten (Netherlands); Daemmgen, Ulrich [Federal Agricultural Research Centre, Institute of Agroecology, D-38116 Braunschweig, (Germany); Fowler, David [CEH, Bush Estate, Penicuik, Midlothian EH26 0QB (United Kingdom); Sutton, Mark [CEH, Bush Estate, Penicuik, Midlothian EH26 0QB (United Kingdom); Gruenhage, Ludger [Institute for Plant Ecology, Justus-Liebig-University, D-35392 Giessen (Germany); Tuovinen, Juha-Pekka [Finnish Meteorological Institute, FIN-00810 Helsinki (Finland)

    2005-02-01

    Monitoring and modelling of deposition of air pollutants is essential to develop and evaluate policies to abate the effects related to air pollution and to determine the losses of pollutants from the atmosphere. Techniques for monitoring wet deposition fluxes are widely applied. A recent intercomparison experiment, however, showed that the uncertainty in wet deposition is relatively high, up to 40%, apart from the fact that most samplers are biased because of a dry deposition contribution. Wet deposition amounts to about 80% of the total deposition in Europe with a range of 10-90% and uncertainty should therefore be decreased. During recent years the monitoring of dry deposition has become possible. Three sites have been operational for 5 years. The data are useful for model development, but also for model evaluation and monitoring of progress in policy. Data show a decline in SO{sub 2} dry deposition, whereas nitrogen deposition remained constant. Furthermore, surface affinities for pollutants changed leading to changes in deposition. Deposition models have been further developed and tested with dry deposition measurements and total deposition measurements on forests as derived from throughfall data. The comparison is reasonable given the measurement uncertainties. Progress in ozone surface exchange modelling and monitoring shows that stomatal uptake can be quantified with reasonable accuracy, but external surface uptake yields highest uncertainty. - Monitoring and modelling of the deposition of sulphur and nitrogen components and the exposure of ozone has gained much progress through the research within BIATEX.

  10. Endogenous monitoring: a new challenge for the regulation of energy externalities

    International Nuclear Information System (INIS)

    Millock, K.

    1999-11-01

    The present article studies the problem of regulating externalities from energy use, with particular emphasis on the problem of information. A standard economics. The article shows how the optimal choice of instruments used to regulate the externalities from energy use will change with the more widespread adoption of modern monitoring technologies. We will illustrate how the application of incentive policies conditioned on monitoring can contribute to the implementation of flexible mechanisms for greenhouse gas abatement. Section 2 briefly summarises the economic framework for the regulation of externalities resulting from energy use. In Section 3, an illustrative model is presented in which the introduction of monitoring of emissions is endogenous and conditions the best type of instrument used by the regulator to internalize the externalities from energy use. Section 4 then examines the implications of this framework for the application of the flexible incentives introduced in the Kyoto Protocol. It shows how the success of project-based approaches, such as Joint Implementation and the Clean Development Mechanism, depends upon the implementation of appropriate incentives for monitoring. Section 5 concludes. (author)

  11. Patient benefit from seamless implant monitoring

    Directory of Open Access Journals (Sweden)

    Karsten Wallbrück

    2005-12-01

    Full Text Available Background: Patients with electrostimulation devices visit the hospital regularly for follow-up. The workload of out-patient departments is ever increasing, but a less frequent check-up is unwanted, as it could impair reliability and effectiveness of the therapy. A system of remote patient monitoring might improve this situation by enabling identification of patients who benefit from a shortened time for corrective action after any undesired event. A completely automatic system for patient remote monitoring has been introduced (BIOTRONIK Home Monitoring, HM. Daily patient and device data are displayed on an internet site which allows authorized persons to follow the parameters trends. Several clinical studies are presently being conducted to investigate the benefit of HM in pacemaker and implantable cardioverter/defibrillator therapy. Preliminary results show the system’s ability to individualize implant therapy for the patients’ and the physicians’ benefits. Previous studies in heart failure (HF therapy have shown that hospital readmission rates, hospitalisation duration and also mortality can be reduced by patient monitoring programs. A recently started study investigating HM in heart failure therapy aims to define a HF-indicator that predicts a worsening of the patient’s status leading to hospitalisation. With such an indicator, the responsible physician could be alerted and the patient can be called in. Although several issues connected to Home Monitoring remain to be solved, the time has come for a more flexible patient management. The incorporation of modern information technology into cardiovascular implants offers a way to solve the conflict between limited resources and high quality medical therapy for an aging population.

  12. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Energy Technology Data Exchange (ETDEWEB)

    Paff, Marc Gerrit, E-mail: mpaff@umich.edu; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-21

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  13. Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

    Science.gov (United States)

    Paff, Marc Gerrit; Di Fulvio, Angela; Clarke, Shaun D.; Pozzi, Sara A.

    2017-03-01

    We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

  14. Modular remote radiation monitor

    International Nuclear Information System (INIS)

    Lacerda, Fabio; Farias, Marcos S.; Aghina, Mauricio A.C.; Oliveira, Mauro V.

    2013-01-01

    The Modular Remote Radiation Monitor (MRRM) is a novel radiation monitor suitable for monitoring environmental exposure to ionizing radiation. It is a portable compact-size low-power microprocessor-based electronic device which provides its monitoring data to other electronic systems, physically distant from it, by means of an electronic communication channel, which can be wired or wireless according to the requirements of each application. Besides its low-power highly-integrated circuit design, the Modular Remote Radiation Monitor is presented in a modular architecture, which promotes full compliance to the technical requirements of different applications while minimizing cost, size and power consumption. Its communication capability also supports the implementation of a network of multiple radiation monitors connected to a supervisory system, capable of remotely controlling each monitor independently as well as visualizing the radiation levels from all monitors. A prototype of the MRRM, functionally equivalent to the MRA-7027 radiation monitor, was implemented and connected to a wired MODBUS network of MRA-7027 monitors, responsible for monitoring ionizing radiation inside Argonauta reactor room at Instituto de Engenharia Nuclear. Based on the highly positive experimental results obtained, further design is currently underway in order to produce a consumer version of the MRRM. (author)

  15. Political connections, media monitoring and long-term loans

    Institute of Scientific and Technical Information of China (English)

    Deming; Yang; Zhengfei; Lu; Danglun; Luo

    2014-01-01

    We analyze data on Chinese non-state-listed firms and find that it is easier for firms with political connections to obtain long-term loans with extended debt maturities than it is for firms without political connections. Our investigation indicates that this phenomenon is significantly less common with increased media monitoring. Houston et al.(2011) find strong evidence that the state ownership of media is associated with higher levels of bank corruption in China, but our study shows that, to a certain extent, media monitoring can curb corruption.

  16. Political connections, media monitoring and long-term loans

    Directory of Open Access Journals (Sweden)

    Deming Yang

    2014-09-01

    Full Text Available We analyze data on Chinese non-state-listed firms and find that it is easier for firms with political connections to obtain long-term loans with extended debt maturities than it is for firms without political connections. Our investigation indicates that this phenomenon is significantly less common with increased media monitoring. Houston et al. (2011 find strong evidence that the state ownership of media is associated with higher levels of bank corruption in China, but our study shows that, to a certain extent, media monitoring can curb corruption.

  17. Environmental monitoring plan

    International Nuclear Information System (INIS)

    Holland, R.C.

    1997-02-01

    This Environmental Monitoring Plan was written to fulfill the requirements of Department of Energy (DOE) Order 5400.1 and DOE Environmental Regulatory Guide DOE/EH 0173T. This Plan documents the background, organizational structure, and methods used for effluent monitoring and environmental surveillance at Sandia National Laboratories/California. The design, rationale, and historical results of the environmental monitoring system are discussed in detail. Throughout the Plan, recommendations for improvements to the monitoring system are made. 52 refs., 10 figs., 12 tabs

  18. Monitoring of MNSR operation by measuring subcritical photoneutron flux

    International Nuclear Information System (INIS)

    Haddad, Kh.; Alsomel, N.

    2011-01-01

    Passive nondestructive assay methods are used to monitor the reactor's operation. It is required for nuclear regulatory, calculation validation and safeguards purposes. So, it plays a vital role in the safety and security of the nuclear plants. The possibility of MNSR operation monitoring by measuring the subcritical state photoneutron flux were investigated in this work. The photoneutron flux is induced by the fuels hard gamma radiation in the beryllium reflector. Theoretical formulation and experimental tests were performed. The results show that within a specified cooling time range, the photoneutron flux is induced by a single dominant hard gamma emitter such as 117 Cd (activation product) and 140 Ba ( 140 La fission product). This phenomenon was utilized to monitor the cooling time and the operation neutron flux during the last campaign. Thus a passive nondestructive assay method is proposed with regard to the reactor operation's monitoring.

  19. Distributed acoustic sensing for pipeline monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hill, David; McEwen-King, Magnus [OptaSense, QinetiQ Ltd., London (United Kingdom)

    2009-07-01

    Optical fibre is deployed widely across the oil and gas industry. As well as being deployed regularly to provide high bandwidth telecommunications and infrastructure for SCADA it is increasingly being used to sense pressure, temperature and strain along buried pipelines, on subsea pipelines and downhole. In this paper we present results from the latest sensing capability using standard optical fibre to detect acoustic signals along the entire length of a pipeline. In Distributed Acoustic Sensing (DAS) an optical fibre is used for both sensing and telemetry. In this paper we present results from the OptaSense{sup TM} system which has been used to detect third party intervention (TPI) along buried pipelines. In a typical deployment the system is connected to an existing standard single-mode fibre, up to 50km in length, and was used to independently listen to the acoustic / seismic activity at every 10 meter interval. We will show that through the use of advanced array processing of the independent, simultaneously sampled channels it is possible to detect and locate activity within the vicinity of the pipeline and through sophisticated acoustic signal processing to obtain the acoustic signature to classify the type of activity. By combining spare fibre capacity in existing buried fibre optic cables; processing and display techniques commonly found in sonar; and state-of-the-art in fibre-optic distributed acoustic sensing, we will describe the new monitoring capabilities that are available to the pipeline operator. Without the expense of retrofitting sensors to the pipeline, this technology can provide a high performance, rapidly deployable and cost effective method of providing gapless and persistent monitoring of a pipeline. We will show how this approach can be used to detect, classify and locate activity such as; third party interference (including activity indicative of illegal hot tapping); real time tracking of pigs; and leak detection. We will also show how an

  20. OPTIMIZING RADIOLOGICAL MONITOR SITING OVER THE CONTINENTAL U.S

    International Nuclear Information System (INIS)

    Chen, K; Robert Buckley, R; Robert Kurzeja, R; Lance Osteen, L; Saleem Salaymeh, S

    2007-01-01

    The US Environmental Protection Agency (EPA) is installing a network of sensors in the US to monitor background radiation and elevated radiation levels expected from a possible nuclear incident. The network (RadNet) of 180 fixed sensors is intended to provide a basic estimate of the radiation level throughout the US and enhanced accuracy near population centers. This report discusses one of the objective methods for locating these monitors based on criteria outlined by the EPA. The analysis employs a representative climatology of incident scenarios that includes 50 release locations, four seasons and four times of the day. This climatology was calculated from 5,600 simulations generated with NOAA-ARL's HYSPLIT Lagrangian trajectory model. The method treats the release plumes as targets and monitors are located to maximize the number of plumes detected with the network. Weighting schemes based on detection only, dose-weighted detection and population-dose weighted detection were evaluated. The result shows that most of the monitors are located around the population centers, as expected. However, there are monitors quite uniformly distributed around the less populated areas. The monitors at the populated areas will provide early warning to protect the general public, and the monitors spread across the country will provide valuable data for modelers to estimate the extent and the transport of the radioactive contamination

  1. Environmental γ radiation monitor

    International Nuclear Information System (INIS)

    Qu Xiaopeng

    1993-01-01

    The environmental γ radiation monitor is a kind of dose or dose rate measuring devices, which can be used for monitoring environmental γ radiation around a nuclear site when normal or even abnormal events occur. The monitor is controlled by a single-chip microcomputer so that it can acquire synchronously the data from four detectors and transfer the data to a central computer. The monitor has good temperature property due to the technique of temperature correction. The monitor has been used in the environment monitoring vehicle for Qinshan Nuclear Power Plant

  2. Smart textiles in neonatal monitoring : enabling unobtrusive monitoring at the NICU

    NARCIS (Netherlands)

    Seoane, F.; Bouwstra, S.; Marquez, J.; Löfhede, J.; Lindecrantz, K.; Chen, W.; Bambang Oetomo, S.; Feijs, L.M.G.

    2012-01-01

    Prematurely born and critically ill babies admitted to the Neonatal Intensive Care Unit require round-the-clock monitoring of vital signs and in special cases additional parameters such as brain functioning monitoring. Although close monitoring is fundamental for a good developmental outcome, the

  3. Stability monitoring of a boiling water reactor

    International Nuclear Information System (INIS)

    Hagen, T.H.J.J. van der; Hoogenboom, J.E.

    1989-01-01

    Stability monitoring is of great importance for optimal plant performance. Decay ratios for several operating conditions show that the Dodewaard BWR is very stable and that pressure lowering, power increase and flux peaking lead to a higher decay ratio (worse stability). 1 fig., 1 tab., 1 ref

  4. Development of miniature γ dose rate monitor with high sensitivity

    International Nuclear Information System (INIS)

    Shi Huilu; Tuo Xianguo; Xi Dashun; Tang Rong; Mu Keliang; Yang Jianbo

    2009-01-01

    This paper introduces a miniature γ dose rate monitor with high sensitivity which design based on single chip microcomputer, it can continue monitoring γ dose rate and then choose wire or wireless communications to sent the monitoring data to host according to the actual conditions. It has two kinds of power supply system, AC power supply system and battery which can be chose by concrete circumstances. The design idea and implementation technology of hardware and software and the system structure of the monitor are detailed illustrated in this paper. The experimental results show that measurable range is 0.1 mR/h-200 mR/h, the sensitivity of γ is 90 cps/mR/h, dead time below 200 us, error of stability below ±10%. (authors)

  5. The Implementation of IS on the Knowledge Management and Mental Models at the Decision-Making Process

    Science.gov (United States)

    2011-03-01

    results. Further attention to the use and refinement of fidelity criteria is important to the evaluation practice (Mowbray, Holter, Teague, & Bybee ...C., Teague, G. B., & Bybee , D. (2003). Fidelity Criteria: Development, Measurement, and Validation. American Journal of Evaluation, 24(3), 315–340

  6. Mobility Monitor

    DEFF Research Database (Denmark)

    Schæbel, Anne-Lise; Dybbro, Karina Løvendahl; Andersen, Lisbeth Støvring

    2015-01-01

    Undersøgelse af digital monitorering af plejehjemsbeboeres vendinger under søvn på Fremtidens Plejehjem, Nørresundby......Undersøgelse af digital monitorering af plejehjemsbeboeres vendinger under søvn på Fremtidens Plejehjem, Nørresundby...

  7. Laminopathies: a Pandora's box of heart failure, bradyarrhythmias and sudden death.

    Science.gov (United States)

    Cabanelas, Nuno; Martins, Vítor Paulo

    2015-02-01

    The LMNA gene encodes a group of proteins that have an important structural and functional role in the cell nucleus. Mutations in this gene have been found in 6% of all forms of dilated cardiomyopathy and in up to 33% of those with conduction system disturbances. Using a case report as an example, we performed a review of the literature on the pathophysiological mechanisms, clinical manifestations, risk stratification and treatment options of cardiac involvement in laminopathies. We present the case of a 46-year-old man, whose ECG showed bizarre voltage criteria for left ventricular hypertrophy and first-degree atrioventricular block, a dilated left ventricle with mildly impaired global systolic function and non-sustained ventricular tachycardia on Holter monitoring, and with a family history of sudden death. Genetic testing identified an LMNA mutation. No ventricular arrhythmias were induced during electrophysiological study. The patient is under close clinical and echocardiographic monitoring and an event loop recorder has been implanted. Phenotypically, myocardial involvement in laminopathies is indistinguishable from other forms of idiopathic dilated cardiomyopathy. Ventricular arrhythmias are common, but the best method for sudden death risk stratification has yet to be established. The few studies that have been performed, with a very limited number of patients, show that factors associated with an unfavorable prognosis are ejection fraction lack of evidence, indications for an implantable cardioverter-defibrillator for primary prevention in this context are the same as conventional indications for other forms of idiopathic dilated cardiomyopathy. Cardiac involvement as a consequence of LMNA mutations generally has a more aggressive natural history than other forms of non-ischemic dilated cardiomyopathy. A high index of suspicion and prompt referral for genetic testing are essential for appropriate therapeutic management. Copyright © 2014 Sociedade

  8. Sampling method of environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    1984-01-01

    This manual provides sampling methods of environmental samples of airborne dust, precipitated dust, precipitated water (rain or snow), fresh water, soil, river sediment or lake sediment, discharged water from a nuclear facility, grains, tea, milk, pasture grass, limnetic organisms, daily diet, index organisms, sea water, marine sediment, marine organisms, and that for tritium and radioiodine determination for radiation monitoring from radioactive fallout or radioactivity release by nuclear facilities. This manual aims at the presentation of standard sampling procedures for environmental radioactivity monitoring regardless of monitoring objectives, and shows preservation method of environmental samples acquired at the samplingpoint for radiation counting for those except human body. Sampling techniques adopted in this manual is decided by the criteria that they are suitable for routine monitoring and any special skillfulness is not necessary. Based on the above-mentioned principle, this manual presents outline and aims of sampling, sampling position or object, sampling quantity, apparatus, equipment or vessel for sampling, sampling location, sampling procedures, pretreatment and preparation procedures of a sample for radiation counting, necessary recording items for sampling and sample transportation procedures. Special attention is described in the chapter of tritium and radioiodine because these radionuclides might be lost by the above-mentioned sample preservation method for radiation counting of less volatile radionuclides than tritium or radioiodine. (Takagi, S.)

  9. Technology monitoring; Technologie-Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Eicher, H.; Rigassi, R. [Eicher und Pauli AG, Liestal (Switzerland); Ott, W. [Econcept AG, Zuerich (Switzerland)

    2003-07-01

    This study made for the Swiss Federal Office of Energy (SFOE) examines ways of systematically monitoring energy technology development and the cost of such technologies in order to pave the way to a basis for judging the economic development of new energy technologies. Initial results of a survey of the past development of these technologies are presented and estimates are made of future developments in the areas of motor-based combined heat and power systems, fuel-cell heating units for single-family homes and apartment buildings, air/water heat pumps for new housing projects and high-performance thermal insulation. The methodology used for the monitoring and analysis of the various technologies is described. Tables and diagrams illustrate the present situation and development potential of various fields of technology.

  10. Heart Rate Variability Density Analysis (Dyx) and Prediction of Long-Term Mortality after Acute Myocardial Infarction

    DEFF Research Database (Denmark)

    Jørgensen, Rikke Mørch; Abildstrøm, Steen Z; Levitan, Jacob

    2016-01-01

    AIMS: The density HRV parameter Dyx is a new heart rate variability (HRV) measure based on multipole analysis of the Poincaré plot obtained from RR interval time series, deriving information from both the time and frequency domain. Preliminary results have suggested that the parameter may provide...... new predictive information on mortality in survivors of acute myocardial infarction (MI). This study compares the prognostic significance of Dyx to that of traditional linear and nonlinear measures of HRV. METHODS AND RESULTS: In the Nordic ICD pilot study, patients with an acute MI were screened...... with 2D echocardiography and 24-hour Holter recordings. The study was designed to assess the power of several HRV measures to predict mortality. Dyx was tested in a subset of 206 consecutive Danish patients with analysable Holter recordings. After a median follow-up of 8.5 years 70 patients had died...

  11. Flood and Traffic Wireless Monitoring System for Smart Cities

    KAUST Repository

    Moussa, Mustafa

    2016-10-01

    The convergence of computation, communication and sensing has led to the emergence of Wireless Sensor Networks (WSNs), which allow distributed monitoring of physical phenomena over extended areas. In this thesis, we focus on a dual flood and traffic flow WSN applicable to urban environments. This fixed sensing system is based on the combination of ultrasonic range-finding with remote temperature sensing, and can sense both phenomena with a high degree of accuracy. This enables the monitoring of urban areas to lessen the impact of catastrophic flood events, by monitoring flood parameters and traffic flow to enable public evacuation and early warning, allocate the resources efficiently or control the traffic to make cities more productive and smarter. We present an implementation of the device, and illustrate its performance in water level estimation and rain detection using a novel combination of L1 regularized reconstruction and machine learning algorithms on a 6-month dataset involving four different sensors. Our results show that water level can be estimated with an uncertainty of 1 cm using a combination of thermal sensing and ultrasonic distance measurements. The demonstration of the performance included the detection of an actual flash flood event using two sensors located in Umm Al Qura University (Mecca). Finally, we show that Lagrangian (mobile) sensors can be used to inexpensively increase the performance of the system with respect to traffic sensing. These sensors are based on Inertial Measurement Units (IMUs), which have never been investigated in the context of traffic ow monitoring before. We investigate the divergence of the speed estimation process, the lack of the calibration parameters of the system, and the problem of reconstructing vehicle trajectories evolving in a given transportation network. To address these problems, we propose an automatic calibration algorithm applicable to IMU-equipped ground vehicles, and an L1 regularized least squares

  12. Verbal monitoring in Parkinson’s disease: A comparison between internal and external monitoring

    Science.gov (United States)

    Mertens, Jolien; Mariën, Peter; Santens, Patrick; Pickut, Barbara A.; Hartsuiker, Robert J.

    2017-01-01

    Patients with Parkinson’s disease (PD) display a variety of impairments in motor and non-motor language processes; speech is decreased on motor aspects such as amplitude, prosody and speed and on linguistic aspects including grammar and fluency. Here we investigated whether verbal monitoring is impaired and what the relative contributions of the internal and external monitoring route are on verbal monitoring in patients with PD relative to controls. Furthermore, the data were used to investigate whether internal monitoring performance could be predicted by internal speech perception tasks, as perception based monitoring theories assume. Performance of 18 patients with Parkinson’s disease was measured on two cognitive performance tasks and a battery of 11 linguistic tasks, including tasks that measured performance on internal and external monitoring. Results were compared with those of 16 age-matched healthy controls. PD patients and controls generally performed similarly on the linguistic and monitoring measures. However, we observed qualitative differences in the effects of noise masking on monitoring and disfluencies and in the extent to which the linguistic tasks predicted monitoring behavior. We suggest that the patients differ from healthy subjects in their recruitment of monitoring channels. PMID:28832595

  13. Environmental radiation monitoring

    International Nuclear Information System (INIS)

    Watanabe, Isao

    2011-01-01

    The samples, pretreatment method, and measurement methods of 'Environmental radioactivity level by prefecture' of Ministry of Education, Culture, Sports, Science and Education (MEXT) is explained. It consists of 1), 'Environmental radioactivity level by prefecture' in normal period, 2) 'Strengthening of Monitoring of Environmental Radioactivity Level by Prefecture' of MEXT at emergency 3) strengthening of monitoring by Fukushima Daiichi nuclear accident, 4) radiation monitoring around the nuclear facility, 5) strengthening of monitoring by MEXT, and 6) quality of monitoring. The survey item and samples etc., of 'Environmental radioactivity level by prefecture', monitoring post, NaI (Tl) scintillation survey meter, sampling and pretreatment methods for radionuclide analysis in normal period, an example of germanium semiconductor detector, gamma ray spectrum of spaghetti from Italy by germanium semiconductor detector, flow chart of radionuclide analysis of fallout in normal period and emergency by germanium semiconductor detector, example of analytical method of radioactive strontium ( ion exchange method), outline of plutonium analytical method for emergency, sampling and pretreatment methods of radionuclides for strengthening, monitoring result around Fukushima Daiichi nuclear plant from June 23 to 24, 2011, change of air dose rate of monitoring post in Mito city from March 14 to 26, 2011, concentration of I-131 and Cs-137 in fallout in Hitachinaka city from March 19 to April 30, 2011, and change of concentration of I-131, Cs-134 and Cs-137 in tap water of Iitate village from March 20 to April 30, 2011, are illustrated. (S.Y.)

  14. Next generation x-ray all-sky monitor

    International Nuclear Information System (INIS)

    Priedhorsky, W. C.; Peele, A. G.; Nugent, K. A.

    1997-01-01

    We set forth a conceptual design for x-ray all-sky monitor based on lobster-eye wide-field telescopes. This instrument, suitable for a small satellite, would monitor the flux of objects as faint as 2x10 -15 W/m 2 (0.5-2.4 keV) on a daily basis with a signal-to-noise of 5. Sources would be located to 1-2 arc-minutes. Detailed simulations show that crosstalk from the cruciform lobster images would not significantly compromise performance. At this sensitivity limit, we could monitor not just x-ray binaries but fainter classes of x-ray sources. Hundreds of active galactic nuclei, coronal sources, and cataclysmic variables could be tracked on a daily basis. Large numbers of fast transients should be visible, including gamma-ray bursts and the soft x-ray breakout of nearby type II supernovae. Long-term x-ray measurements will advance our understanding of the geometries and perhaps masses of AGN, and coronal energy sources in stars

  15. Descriptive evaluation of holter recordings at a teaching hospital in ...

    African Journals Online (AJOL)

    Wide QRS complex tachycardia was detected in 20.4%, ST segment depression in 47.8% and atrial fibrillation in 28.7%. Asystole was seen in 18% of subjects with a mean duration of 2.17secs, arrest was recorded in 26.7% of those with asystole. The longest duration was 7.58secs. Premature atrial ectopics were seen in ...

  16. Efficient color correction method for smartphone camera-based health monitoring application.

    Science.gov (United States)

    Duc Dang; Chae Ho Cho; Daeik Kim; Oh Seok Kwon; Jo Woon Chong

    2017-07-01

    Smartphone health monitoring applications are recently highlighted due to the rapid development of hardware and software performance of smartphones. However, color characteristics of images captured by different smartphone models are dissimilar each other and this difference may give non-identical health monitoring results when the smartphone health monitoring applications monitor physiological information using their embedded smartphone cameras. In this paper, we investigate the differences in color properties of the captured images from different smartphone models and apply a color correction method to adjust dissimilar color values obtained from different smartphone cameras. Experimental results show that the color corrected images using the correction method provide much smaller color intensity errors compared to the images without correction. These results can be applied to enhance the consistency of smartphone camera-based health monitoring applications by reducing color intensity errors among the images obtained from different smartphones.

  17. Development of multianalyte sensor arrays for continuous monitoring of pollutants

    International Nuclear Information System (INIS)

    Healey, B.G.; Chadha, S.; Walt, D.R.

    1995-01-01

    Industrial development has led to the release of numerous hazardous materials into the environment, posing a potential threat to surrounding waters. Environmental analysis of sites contaminated by several chemicals calls for continuous monitoring of multiple analytes. Monitoring can be achieved by using imaging bundles (300--400microm in diameter), containing several thousand individual optical fibers for the fabrication of sensors. Multiple sensor sites are created at the distal end of the fiber by immobilizing different analyte specific fluorescent dyes. By coupling these imaging fibers to a charge coupled device (CCD), one has the ability to spatially and spectrally discriminate the multiple sensing sites simultaneously and hence monitor analyte concentrations. Prior to immobilization of the dye the distal end of the fiber is functionalized to permit covalent attachment of the polymer matrix. Discrete regions of the fiber bundle are successively illuminated through the proximal end so as to photo-polymerize the polymer matrix containing the fluorescent dyes. Current studies focus on the development of a multi-analyte sensor for monitoring Al +3 , pH, hydrocarbons and uranyl ion. For the monitoring of Al +3 , a variety of indicators are being evaluated for their applicability to sensor design. Lumogallion immobilized in poly HEMA shows considerable sensitivity and dynamic range. The fluorescent indicator eosin has been identified as the indicator for monitoring pH in the range 2.0--4.5. The indicator can be immobilized in an analogous fashion to fluoresce in 3 (pH 4.5--8.0). Hydrocarbon sensors have been fabricated from different photo-polymers that show response to several hydrocarbons using Nile Red as the indicator

  18. 10^{7}-A load-current B-dot monitor: Simulations, design, and performance

    Directory of Open Access Journals (Sweden)

    D. V. Rose

    2010-04-01

    Full Text Available A B-dot monitor that measures the current 6 cm from the axis of dynamic loads fielded on 10^{7}-A multiterawatt pulsed-power accelerators has been developed. The monitor improves upon the multimegampere load-current gauge described in Phys. Rev. ST Accel. Beams 11, 100401 (2008PRABFM1098-440210.1103/PhysRevSTAB.11.100401. The design of the improved monitor was developed using three-dimensional particle-in-cell simulations that model vacuum electron flow in the transmission line near the monitor. The simulations include important geometric features of the B-dot probe and model the deposition of electron energy within the probe. The simulations show that the improved design reduces by as much as a factor of 5 the electron energy deposition to the interior of the monitor. Data taken on accelerator shots demonstrate that the improved monitor works as well as the original monitor on shots with low-impedance loads, and delivers superior performance on higher-impedance-load shots.

  19. Initial commissioning results from the APS loss monitor system

    International Nuclear Information System (INIS)

    Patterson, D.R.

    1996-01-01

    The design of the beam loss monitor system for the Argonne National Laboratory Advanced Photon Source is based on using a number of air dielectric coaxial cables as long ionization chambers. Results to date show that the loss monitor is useful in helping to determine the cause of injection losses and losses large enough to limit circulating currents in the storage ring to short lifetimes. Sensitivities ranging from 13 to 240 pC of charge collected in the injector BTS (booster-to-storage-ring) loss monitor per picocoulomb of loss have been measured, depending on the loss location. These results have been used to predict that the storage ring loss monitor leakage current limit of 10 pA per cable should allow detection of losses resulting in beam lifetimes of 100 hours or less with 100 mA stored beam. Significant DC bias levels associated with the presence of stored beam have been observed. These large bias levels are most likely caused by the loss monitor responding to hard x-ray synchrotron radiation. No such response to synchrotron radiation was observed during earlier tests at SSRL. However, the loss monitor response to average stored beam current in APS has provided a reasonable alternative to the DC current transformer (DCCT) for measuring beam lifetimes

  20. Transformative monitoring approaches for reprocessing.

    Energy Technology Data Exchange (ETDEWEB)

    Cipiti, Benjamin B.

    2011-09-01

    The future of reprocessing in the United States is strongly driven by plant economics. With increasing safeguards, security, and safety requirements, future plant monitoring systems must be able to demonstrate more efficient operations while improving the current state of the art. The goal of this work was to design and examine the incorporation of advanced plant monitoring technologies into safeguards systems with attention to the burden on the operator. The technologies examined include micro-fluidic sampling for more rapid analytical measurements and spectroscopy-based techniques for on-line process monitoring. The Separations and Safeguards Performance Model was used to design the layout and test the effect of adding these technologies to reprocessing. The results here show that both technologies fill key gaps in existing materials accountability that provide detection of diversion events that may not be detected in a timely manner in existing plants. The plant architecture and results under diversion scenarios are described. As a tangent to this work, both the AMUSE and SEPHIS solvent extraction codes were examined for integration in the model to improve the reality of diversion scenarios. The AMUSE integration was found to be the most successful and provided useful results. The SEPHIS integration is still a work in progress and may provide an alternative option.

  1. Monitoring of transport contamination

    International Nuclear Information System (INIS)

    Turkin, N.F.

    1980-01-01

    Organization of monitoring of transport contamination is considered. A particularly thorough monitoring is recommended to be carried out in loading-unloading operations. The monitoring is performed when leaving loading-unloading site and zone under control and prior to preventive examination, technical service or repair. The method of monitoring of auto transport contamination with high-energy β-emitters by means of a special stand permitting the automation of the monitoring process is described [ru

  2. Who Wants to Save the Forest? Characterizing Community-Led Monitoring in Prey Lang, Cambodia

    Science.gov (United States)

    Turreira-García, Nerea; Meilby, Henrik; Brofeldt, Søren; Argyriou, Dimitris; Theilade, Ida

    2018-06-01

    Community monitoring is believed to be successful only where there is sustained funding, legislation for communities to enforce rules, clear tenure rights, and an enabling environment created by the state. Against this backdrop, we present the case of an autonomous grassroots-monitoring network that took the initiative to protect their forest, in a context, where no external incentives and rule enforcement power were provided. The aim was to analyze the socio-demographic and economic backgrounds, motivations and achievements of forest monitors, compared to non-monitors in the same communities. A total of 137 interviews were conducted in four villages bordering Prey Lang forest in Cambodia. We used binary logit models to identify the factors that influenced the likelihood of being a monitor. Results show that there were few (22%, n = 30) active monitors. Active monitors were intrinsically motivated forest-users, and not specifically associated with a particular gender, ethnicity, or residence-time in that area. The most common interventions were with illegal loggers, and the monitors had a general feeling of success in stopping the illegal activities. Most (73%, n = 22) of them had been threatened by higher authorities and loggers. Our results show that despite the lack of power to enforce rules, absence of external funding and land-ownership rights, and enduring threats of violence and conflicts, autonomous community monitoring may take place when community members are sufficiently motivated by the risk of losing their resources.

  3. Is it me? Verbal self-monitoring neural network and clinical insight in schizophrenia.

    Science.gov (United States)

    Sapara, Adegboyega; Ffytche, Dominic H; Cooke, Michael A; Williams, Steven C R; Kumari, Veena

    2015-12-30

    Self-monitoring, defined as the ability to distinguish between self-generated stimuli from other-generated ones, is known to be impaired in schizophrenia. This impairment has been theorised as the basis for many of the core psychotic symptoms, in particular, poor clinical insight. This study aimed to investigate verbal self-monitoring related neural substrates of preserved and poor clinical insight in schizophrenia. It involved 40 stable schizophrenia outpatients, 20 with preserved and 20 with poor insight, and 20 healthy participants. All participants underwent functional magnetic resonance imaging with brain coverage covering key areas in the self-monitoring network during a verbal self-monitoring task. Healthy participants showed higher performance accuracy and greater thalamic activity than both preserved and poor insight patient groups. Preserved insight patients showed higher activity in the putamen extending into the caudate, insula and inferior frontal gyrus, compared to poor insight patients, and in the anterior cingulate and medial frontal gyrus, compared to healthy participants. Poor insight patients did not show greater activity in any brain area compared to preserved insight patients or healthy participants. Future studies may pursue therapeutic avenues, such as meta-cognitive therapies to promote self-monitoring or targeted stimulation of relevant brain areas, as means of enhancing insight in schizophrenia. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  4. Environmental, political, and economic determinants of water quality monitoring in Europe

    Science.gov (United States)

    Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna

    2010-11-01

    Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.

  5. Monitor resultaten geluid 2000

    NARCIS (Netherlands)

    Jabben J; Potma CJM; Swart WJR; LLO

    2001-01-01

    As part of an enhanced effort in monitoring the environmental quality in 1999, the RIVM set up a noise monitoring programme. This programme forms part of the project, "Development of a monitoring system for noise and disturbance", which aims at establishing a number of permanent sites for monitoring

  6. Monitoring Biodiversity using Environmental DNA

    DEFF Research Database (Denmark)

    Thomsen, Philip Francis

    DNA). Especially the advance in DNA sequencing technology has revolutionized this field and opened new frontiers in ecology, evolution and environmental sciences. Also, it is becoming a powerful tool for field biologist, with new and efficient methods for monitoring biodiversity. This thesis focuses on the use...... of eDNA in monitoring of biodiversity in different settings. First, it is shown that a diversity of rare freshwater animals – representing amphibians, fish, mammals, insects and crustaceans – can be detected based on eDNA obtained directly from 15 ml water samples of lakes, ponds and streams...... setting, showing that eDNA obtained directly from ½ l seawater samples can account for marine fish biodiversity using NGS. Promisingly, eDNA covered the fish diversity better than any of 9 methods, conventionally used in marine fish surveys. Additionally, it is shown that even short 100-bp. fish e...

  7. PPP Sliding Window Algorithm and Its Application in Deformation Monitoring

    Science.gov (United States)

    Song, Weiwei; Zhang, Rui; Yao, Yibin; Liu, Yanyan; Hu, Yuming

    2016-01-01

    Compared with the double-difference relative positioning method, the precise point positioning (PPP) algorithm can avoid the selection of a static reference station and directly measure the three-dimensional position changes at the observation site and exhibit superiority in a variety of deformation monitoring applications. However, because of the influence of various observing errors, the accuracy of PPP is generally at the cm-dm level, which cannot meet the requirements needed for high precision deformation monitoring. For most of the monitoring applications, the observation stations maintain stationary, which can be provided as a priori constraint information. In this paper, a new PPP algorithm based on a sliding window was proposed to improve the positioning accuracy. Firstly, data from IGS tracking station was processed using both traditional and new PPP algorithm; the results showed that the new algorithm can effectively improve positioning accuracy, especially for the elevation direction. Then, an earthquake simulation platform was used to simulate an earthquake event; the results illustrated that the new algorithm can effectively detect the vibrations change of a reference station during an earthquake. At last, the observed Wenchuan earthquake experimental results showed that the new algorithm was feasible to monitor the real earthquakes and provide early-warning alerts. PMID:27241172

  8. Internal quality control program for individual monitoring service

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, Claudia L.P.; Moura Junior, Jose; Patrao, Karla C.S. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)]. E-mail: claudia@ird.gov.br; moura@ird.gov.br; karla@ird.gov.br

    2007-07-01

    With a focus on continuous improvement, since 2002, a special internal procedure for following and checking the performance of our individual monitoring services has been implemented. A fictitious installation, named 'Fantasma' has been created, initially, with 4 film badges and 7 thermoluminescent dosimetric ring users. Since 2005, this quality control program includes also the albedo neutron individual monitoring service. Monthly, the 'Fantasma' test monitors are irradiated by traceable Cs-137 and Am-Be sources. The calibration quantities are: the photon dose equivalent (H{sub x}) for the photographic individual monitor, the maximum dose equivalent (MADE) for the albedo neutron individual monitor and the personal dose equivalent at 0.07 mm depth (H{sub p}(0.07)) for ring monitor. Up to now, all results show compliance with the specific trumpet curves acceptance limits. Once, a small sub-evaluation tendency has been noted and this information was used to improve the film system. For the photographic film system, the evaluated value to reference dose ratios range from 0.71 to 1.12, with a mean value of 0.91 {+-} 0.12. For the ring system, the ratio ranges from 0.69 to 1.40, with a mean value of 1.02 {+-} 0.07. For the neutron system, which presents intrinsic larger uncertainties, the ratio ranged from 0.67 to 1.88, with mean value of 1.16 {+-} 0.27. (author)

  9. On-line monitoring of low-level plutonium concentrations

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Huff, G.A.; Rebagay, T.V.

    1979-10-01

    An on-line monitor has been developed to assay plutonium in nitric acid solutions. The performance of the monitor has been assessed by a laboratory experimentation program using solutions with plutonium concentrations from 0.1 to 10 g/l. These conditions are typical of the plutonium solutions in an input stream to a plutonium-purification cycle in a reprocessing plant following uranium/plutonium partitioning. The monitoring system can be fully automated and shows great promise for detecting and quantifying plutonium in situ, thus minimizing the reliance on traditional sampling and laboratory-analysis techniques. The total concentration and isotopic abundance of plutonium are determined by measuring the absolute intensities of the low-energy gamma rays characteristics of 238 Pu, 239 Pu, and 240 Pu nuclides by direct gamma-ray spectroscopy and computer analysis of the spectral data. The addition of a monitoring system of this type to the input stream of a plutonium-purification cycle along with other suitable monitors on the waste streams and on the product stream provides the basis for a near real-time materials control and inventory system. Results of the laboratory-evaluation program employing plutonium in solutions with isotopic compositions typical of those involved in processing light water reactor fuels are presented. The detailed design of a monitoring cell and detection system is given. The precision and accuracy of the results relative to those measured by mass spectrometry and controlled potential coulometry are also summarized

  10. Towards a biological monitoring guidance value for acrylamide.

    Science.gov (United States)

    Sams, C; Jones, K; Warren, N; Cocker, J; Bell, S; Bull, P; Cain, M

    2015-08-19

    Acrylamide is classified as a potential human carcinogen and neurotoxicant. Biological monitoring is a useful tool for monitoring worker exposure. However, other sources of exposure to acrylamide (including cigarette smoke and diet) also need to be considered. This study has performed repeat measurements of the urinary mercapturic acids of acrylamide (AAMA) and its metabolite glycidamide (GAMA) and determined globin adducts in 20 production-plant workers at a UK acrylamide production facility. The relationship between biomarker levels and environmental monitoring data (air levels and hand washes) was investigated. Good correlations were found between all of the biomarkers (r(2)=0.86-0.91) and moderate correlations were found between the biomarkers and air levels (r(2) = 0.56-0.65). Our data show that urinary AAMA is a reliable biomarker of acrylamide exposure. Occupational hygiene data showed that acrylamide exposure at the company was well within the current UK Workplace Exposure Limit. The 90th percentile of urinary AAMA in non-smoking production-plant workers (537 μmol/mol creatinine (n = 59 samples)) is proposed as a possible biological monitoring guidance value. This 90th percentile increased to 798 μmol/mol if smokers were included (n = 72 samples). These values would be expected following an airborne exposure of less than 0.07 mg/m(3), well below the current UK workplace exposure limit of 0.3mg/m(3). Comparison of biomarker levels in non-occupationally exposed individuals suggests regional variations (between UK and Germany), possibly due to differences in diet. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Uncertainty Monitoring by Young Children in a Computerized Task

    Directory of Open Access Journals (Sweden)

    Michael J. Beran

    2012-01-01

    Full Text Available Adult humans show sophisticated metacognitive abilities, including the ability to monitor uncertainty. Unfortunately, most measures of uncertainty monitoring are limited to use with adults due to their general complexity and dependence on explicit verbalization. However, recent research with nonhuman animals has successfully developed measures of uncertainty monitoring that are simple and do not require explicit verbalization. The purpose of this study was to investigate metacognition in young children using uncertainty monitoring tests developed for nonhumans. Children judged whether stimuli were more pink or blue—stimuli nearest the pink-blue midpoint were the most uncertain and the most difficult to classify. Children also had an option to acknowledge difficulty and gain the necessary information for correct classification. As predicted, children most often asked for help on the most difficult stimuli. This result confirms that some metacognitive abilities appear early in cognitive development. The tasks of animal metacognition research clearly have substantial utility for exploring the early developmental roots of human metacognition.

  12. State of the art in monitoring respirable mine aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Volkwein, J.C.; Mischler, S.E.; Thimons, E.D.; Timko, R.J.; Kissell, F.N.

    2005-07-01

    The Centers for Disease Control and Prevention (CDC), National Institute for Occupational Safety and Health (NIOSH) has been developing several new tools to help miners monitor respirable coal dust, silica, and diesel particulate matter. This paper discusses three main topics. First, the latest results of the person wearable dust monitor (PDM), developed by Rupprecht and Patashnick under CDC contract. The PDM was tested side by side with conventional samplers at a number of US coal mines and results indicated that the PDM was comparable to conventional samplers. Second, improvements to the Dust Dosimeter monitoring technique that includes a new pump with built in pressure transducer and algorithm to convert differential pressure to dust concentration have shown good precision. Third, advances in the use of the detector tube technique to monitor tailpipe diesel emissions and ambient diesel particulate matter show that strong correlations exist between differential pressure measurement and elemental carbon in the samplers. 3 figs.

  13. Quality assurance of environmental gamma radiation monitoring in Slovenia

    International Nuclear Information System (INIS)

    Stuhec, M.; Zorko, B.; Mitic, D.; Miljanic, S.; Ranogajec-Komor, M.

    2006-01-01

    Environmental gamma radiation monitoring established in Slovenia consists of a network of multifunctional gamma monitors (MFMs) based on pairs of Geiger-Mueller counters and a network of measuring sites with high-sensitive thermoluminescence dosemeters. The measuring points are evenly spread across Slovenia, located at the meteorological stations and more densely on additional locations around the Krsko NPP. The MFM network has a 2-fold function with one sensor used for the purpose of early warning system in near surroundings of the NPP and the other, more sensitive, for natural radiation monitoring. The paper summarises activities to establish quality assurance of the environmental gamma radiation measurements in Slovenia, with a critical view of the results in comparison with the international standards and recommendations. While the results of linearity and energy dependence tests were satisfying, on-field intercomparison showed that the inherent signal of one of the monitors (MFM) has to be taken into account in the range of environmental background radiation. (authors)

  14. Error monitoring issues for common channel signaling

    Science.gov (United States)

    Hou, Victor T.; Kant, Krishna; Ramaswami, V.; Wang, Jonathan L.

    1994-04-01

    Motivated by field data which showed a large number of link changeovers and incidences of link oscillations between in-service and out-of-service states in common channel signaling (CCS) networks, a number of analyses of the link error monitoring procedures in the SS7 protocol were performed by the authors. This paper summarizes the results obtained thus far and include the following: (1) results of an exact analysis of the performance of the error monitoring procedures under both random and bursty errors; (2) a demonstration that there exists a range of error rates within which the error monitoring procedures of SS7 may induce frequent changeovers and changebacks; (3) an analysis of the performance ofthe SS7 level-2 transmission protocol to determine the tolerable error rates within which the delay requirements can be met; (4) a demonstration that the tolerable error rate depends strongly on various link and traffic characteristics, thereby implying that a single set of error monitor parameters will not work well in all situations; (5) some recommendations on a customizable/adaptable scheme of error monitoring with a discussion on their implementability. These issues may be particularly relevant in the presence of anticipated increases in SS7 traffic due to widespread deployment of Advanced Intelligent Network (AIN) and Personal Communications Service (PCS) as well as for developing procedures for high-speed SS7 links currently under consideration by standards bodies.

  15. A real time status monitor for transistor bank driver power limit resistor in boost injection kicker power supply

    Energy Technology Data Exchange (ETDEWEB)

    Mi, J.; Tan, Y.; Zhang, W.

    2011-03-28

    For years suffering of Booster Injection Kicker transistor bank driver regulator troubleshooting, a new real time monitor system has been developed. A simple and floating circuit has been designed and tested. This circuit monitor system can monitor the driver regulator power limit resistor status in real time and warn machine operator if the power limit resistor changes values. This paper will mainly introduce the power supply and the new designed monitoring system. This real time resistor monitor circuit shows a useful method to monitor some critical parts in the booster pulse power supply. After two years accelerator operation, it shows that this monitor works well. Previously, we spent a lot of time in booster machine trouble shooting. We will reinstall all 4 PCB into Euro Card Standard Chassis when the power supply system will be updated.

  16. HEMOSTASIOLOGICAL MONITORING DURING PREGNANCY

    Directory of Open Access Journals (Sweden)

    I. V. Medyannikova

    2014-01-01

    Full Text Available As gestation progresses, all hemostatic components show changes aimed at compensating for the expenditures associated with fetal development. Activation of the hemostatic system during pregnancy creates a premorbid background for thrombotic and hemorrhagic complications. Hemostasiological examination is one of the compulsory dispensary management stages for pregnant women. An algorithm for the diagnosis of pregnancy-associated disorders in the hemostatic system is to solve the following problems: to identify the causes of hemocoagulation disorders, to determine the risk of thrombotic and hemorrhagic disorders, to prevent obstetric complications, and to monitor antithrombotic therapy. Hemostatic monitoring in pregnant women is based on rating and special methods and includes 3 stages: early, extended, and differential.The need for extended hemostatic examination is first determined and the direction of a search for a defective component is concretized in relation of the changes found. Interpretation of laboratory test values in terms of a female medical history and gestational age underlies the timely diagnosis, adequate treatment policy, and effective prevention of gestational complications.

  17. A wireless sensor network design and evaluation for large structural strain field monitoring

    International Nuclear Information System (INIS)

    Qiu, Zixue; Wu, Jian; Yuan, Shenfang

    2011-01-01

    Structural strain changes under external environmental or mechanical loads are the main monitoring parameters in structural health monitoring or mechanical property tests. This paper presents a wireless sensor network designed for monitoring large structural strain field variation. First of all, a precision strain sensor node is designed for multi-channel strain gauge signal conditioning and wireless monitoring. In order to establish a synchronous strain data acquisition network, the cluster-star network synchronization method is designed in detail. To verify the functionality of the designed wireless network for strain field monitoring capability, a multi-point network evaluation system is developed for an experimental aluminum plate structure for load variation monitoring. Based on the precision wireless strain nodes, the wireless data acquisition network is deployed to synchronously gather, process and transmit strain gauge signals and monitor results under concentrated loads. This paper shows the efficiency of the wireless sensor network for large structural strain field monitoring

  18. Technical evaluation of a radon daughter continuous monitor in an underground uranium mine

    International Nuclear Information System (INIS)

    Bigu, J.; Grenier, M.

    1982-07-01

    An evaluation of a radon daughter monitor was carried out in an underground uranium mine. The monitor operates on continuous sampling and time integrating principles. Experimental and theoretical data were compared. Experimental results show that the monitor underestimates the Working Level, a fact which is partly attributed to plate-out of decay products in the monitor sampling head. However, a correction factor experimentally determined by standard calibration procedures can be programmed into the monitor to take into account losses by plate-out and other losses. Although the monitor was originally designed for radon daughters, it can equally be used in thoron daughter atmospheres and radon daughter/thoron daughter mixtures such as those encountered in some Canadian uranium mines. An analytical procedure is outlined to allow the calculation of Working Levels in radon daughter/thoron daughter atmospheres from the monitor α-count rate. The memory capability of the monitor should make it quite useful and flexible in underground and surface environments in the uranium mining industry

  19. USB-based radiation monitor

    International Nuclear Information System (INIS)

    Drndarevic, V.; Jevtic, N.; Djuric, R.

    2006-01-01

    The Universal Serial Bus has become a dominant interface for the connection of standard peripheral devices to a personal computer. This paper analyzes the possibilities of USB bus applications in the field of measurement and environmental monitoring. As a result, a gamma radiation monitor consisting of an USB-based universal peripheral device and a gamma probe with a GM counter, has been designed. For the interfacing monitor with the powerful and easy to use LabVIEW software package, an instrument driver as a set of virtual instruments has been developed. The proposed monitor is a flexible instrument which can be used for laboratory measurements, as an environmental radiation monitor or for training purposes. Connected to the laptop computer, the monitor becomes a portable instrument suitable for field measurements. Basic measurements and functionality properties of the radiation monitor are presented here

  20. High accuracy digital aging monitor based on PLL-VCO circuit

    International Nuclear Information System (INIS)

    Zhang Yuejun; Jiang Zhidi; Wang Pengjun; Zhang Xuelong

    2015-01-01

    As the manufacturing process is scaled down to the nanoscale, the aging phenomenon significantly affects the reliability and lifetime of integrated circuits. Consequently, the precise measurement of digital CMOS aging is a key aspect of nanoscale aging tolerant circuit design. This paper proposes a high accuracy digital aging monitor using phase-locked loop and voltage-controlled oscillator (PLL-VCO) circuit. The proposed monitor eliminates the circuit self-aging effect for the characteristic of PLL, whose frequency has no relationship with circuit aging phenomenon. The PLL-VCO monitor is implemented in TSMC low power 65 nm CMOS technology, and its area occupies 303.28 × 298.94 μm 2 . After accelerating aging tests, the experimental results show that PLL-VCO monitor improves accuracy about high temperature by 2.4% and high voltage by 18.7%. (semiconductor integrated circuits)

  1. Acoustic monitoring techniques for corrosion degradation in cemented waste canisters

    International Nuclear Information System (INIS)

    Naish, C.C.; Buttle, D.; Wallace-Sims, R.; O'Brien, T.M.

    1991-01-01

    This report describes work to investigate acoustic emission as a non-intrusive monitor of corrosion and degradation of cemented wasteforms where the waste is a potentially reactive metal. The acoustic data collected shows good correlation with the corrosion rate as measured by hydrogen gas evolution rates and the electrochemically measured corrosion rates post cement hardening. The technique has been shown to be sensitive in detecting stress caused by expansive corrosion product within the cemented wasteform. The attenuation of the acoustic signal by the wasteform reduced the signal received by the monitoring equipment by a factor of 10 over a distance of approximately 150-400 mm, dependent on the water level in the cement. Full size packages were successfully monitored. It is concluded that the technique offers good potential for monitoring cemented containers of the more reactive metals, for example Magnox and aluminium. (author)

  2. Environmental radiation monitoring from the decommission of TRIGA

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Geun Sik; Lee, Chang Woo

    2000-03-01

    Environmental radiation monitoring was carried out with measurement of environmental radiation and environmental radioactivity analysis around TRIGA Research Reactor. The results of environmental radiation monitoring around TRIGA Research Reactor are the follows: The average level of environmental radiation measured by potable ERM and accumulated radiation dose by TLD was almost same level compared with thepast years. Gross {beta} radioactivity in environmental samples showed a environmental level. {gamma}-radionuclides in water samples were not detected. but only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. (author)

  3. Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Mittal, Suneet; Ruwald, Anne-Christine

    2014-01-01

    -defibrillator device with data available on biventricular pacing percentage and pre-implantation 24-h Holter recordings were included. Using logistic regression, we estimated the influence of ectopic beats on the percentage of biventricular pacing. Reverse remodeling was measured as reductions in atrial and left...

  4. 76 FR 25732 - Order of Suspension of Trading; In the Matter of Advanced Refractive Technologies, Inc., Bluebook...

    Science.gov (United States)

    2011-05-05

    ... of Advanced Refractive Technologies, Inc., Bluebook International Holding Co. (The), CBCom, Inc., Gener8xion Entertainment, Inc., Group Long Distance Inc., HiEnergy Technologies, Inc., and Holter Technologies Holding, A.G. (n/k/a International Consortium Corp.) It appears to the Securities and Exchange...

  5. Water Level Loggers as a Low-Cost Tool for Monitoring of Stormwater Control Measures

    Directory of Open Access Journals (Sweden)

    Laura Toran

    2016-08-01

    Full Text Available Stormwater control measures (SCMs are a key component of watershed health in urbanized areas. SCMs are used to increase infiltration and reduce discharge to streams or storm sewer systems during rain events. Monitoring is important for the evaluation of design and causes of failure in SCMs. However, the expense of monitoring means it is not always included in stormwater control planning. This study shows how low-cost water level loggers can be used to answer certain questions about SCM performance. Five case studies are presented that use water level loggers to evaluate the overflow of basins, compare a traditional stormpipe trench with an infiltration trench, monitor timing of blue roof storage, show the effects of retrofitting a basin, and provide long term performance data. Water level loggers can be used to answer questions about the timing and location of stormwater overflows, which helps to evaluate the effectiveness of SCMs. More expensive monitoring and modeling can be used as a follow up if needed to more thoroughly assess a site. Nonetheless, low-cost monitoring can be a first step in identifying sites that need improvement or additional monitoring.

  6. Quality and Safety of Home ICP Monitoring Compared with In-Hospital Monitoring

    DEFF Research Database (Denmark)

    Andresen, Morten; Juhler, Marianne; Munch, Tina Nørgaard

    2012-01-01

    Introduction: Intracranial pressure (ICP) monitoring is usually conducted in-hospital using stationary devices. Modern mobile ICP monitoring systems present new monitoring possibilities more closely following the patients' daily life. We reviewed patient safety, quality of technical data...

  7. Visual metaphors on anaesthesia monitors do not improve anaesthetists' performance in the operating theatre

    NARCIS (Netherlands)

    van Amsterdam, K.; Cnossen, F.; Ballast, A.; Struys, M. M. R. F.

    Background. Previous research using a metaphorical anaesthesia monitor, where dimensions of rectangles proportionally represent 30 patient variable values, showed improved performance in diagnosing adverse events compared with the standard monitor. Steady-state values were represented by a frame

  8. Analysis of Land Subsidence Monitoring in Mining Area with Time-Series Insar Technology

    Science.gov (United States)

    Sun, N.; Wang, Y. J.

    2018-04-01

    Time-series InSAR technology has become a popular land subsidence monitoring method in recent years, because of its advantages such as high accuracy, wide area, low expenditure, intensive monitoring points and free from accessibility restrictions. In this paper, we applied two kinds of satellite data, ALOS PALSAR and RADARSAT-2, to get the subsidence monitoring results of the study area in two time periods by time-series InSAR technology. By analyzing the deformation range, rate and amount, the time-series analysis of land subsidence in mining area was realized. The results show that InSAR technology could be used to monitor land subsidence in large area and meet the demand of subsidence monitoring in mining area.

  9. [Experimental research on the electromagnetic radiation immunity of a kind of portable monitor].

    Science.gov (United States)

    Yuan, Jun; Xiao, Dongping; Jian, Xin

    2010-11-01

    The paper is focused on a kind of portable monitor that is widely used in military hospitals. In order to study the electromagnetic radiation immunity of the monitor, the experiments of electromagnetic radiation caused by radio frequency continuous wave in reverberation chamber and by ultra wide band (UWB) electromagnetic pulse have been done. The study results show that UWB electromagnetic pulse interferes observably the operating state of the monitor. It should be paid high attention to take protective measures. The monitor tested has some electromagnetic immunity ability for radio frequency continuous wave radiation. The frequent abnormal phenomena are baseline drift and waveform distortion. The electromagnetic sensitivity of the monitor is related to the frequency of interference source. The monitor tested is most sensitive to the frequency of 390 MHz.

  10. In situ monitoring of the electrochemical dissolution of tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Krebsz, Melinda [Christian Doppler Laboratory for Combinatorial Oxide Chemistry at ICTAS, Johannes Kepler University Linz (Austria); Kollender, Jan Philipp [Institute for Chemical Technology of Inorganic Materials (ICTAS), Johannes Kepler University Linz (Austria); Hassel, Achim Walter [Christian Doppler Laboratory for Combinatorial Oxide Chemistry at ICTAS, Johannes Kepler University Linz (Austria); Institute for Chemical Technology of Inorganic Materials (ICTAS), Johannes Kepler University Linz (Austria)

    2017-09-15

    In the present work, which is aimed to monitor in situ the electrochemical dissolution of tungsten by using a Flow-Type Scanning Droplet Cell Microscope (FT-SDCM) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS), novel results are reported. The anodic oxide growth and its dissolution on the surface of W have been monitored in situ. The results of this current study show the importance of coupling electrochemical experiments to ICP-MS. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. EPRI's zebra mussel monitoring and control guidelines

    International Nuclear Information System (INIS)

    Mussalli, Y.G.; Armor, A.; Edwards, R.; Mattice, J.; Miller, M.; Nott, B.; Tsou, J.L.

    1992-01-01

    The Electric Power Research Institute (EPRI) Zebra Mussel Monitoring and Control Guidelines is a comprehensive compilation of US and European practices. The zebra mussel has infested all the Great Lakes and is positioned to spread to the adjoining river basins. The impact of the zebra mussel on power plants is as a biofouler clogging water systems and heat exchangers. The EPRI guidelines discuss the distribution of the zebra mussel in the US, identification of the zebra mussel, potential threats to power plants, and methods to initiate the monitoring and control program. Both preventive and corrective measures are presented. Preventive measures include various monitoring methods to initiate control techniques. The control techniques include both chemical and nonchemical together with combining techniques. Corrective methods include operational considerations, chemical cleaning, and mechanical/physical cleaning. It may also be possible to incorporate design changes, such as open to closed-loop backfit, backflushing, or pretreatment for closed systems. Table 1 shows a matrix of the monitoring methods. Table 2 presents a control matrix related to nuclear, fossil, and hydro raw water systems. Table 3 is a summary of the applicability of treatments to the various raw water systems. Appendixes are included that contain specifications to aid utilities in implementing several of the control technologies

  12. Study on intermediate frequency power supply automatic monitor system

    International Nuclear Information System (INIS)

    Wang Yuntong; Xu Bin

    2007-06-01

    A new design project of the automatic monitor system for the intermediate frequency power supply system by using the communication server is put for- ward and the realizing principle method and the key technique are clarified in detail. This system made use of the conversion function with the series communication server's control, realized the data collecting function by the double machine backup and redundancy. The new network system adopted the photoelectric-insulated-communication connect device and the diagnosis technique, increased the anti-interference ability, the communication adopted the technique by the alarm information sending out in first and circularly repeating, the slowly speed is overcame in the original monitor network system, and strengthened the celerity of the monitor system and the reliability of the alarm report. After the new monitor system running, the result shows that the functions is more perfect than the original monitor system, the usage is more convenient, have the higher and dependable stability, the report of alarm is more quickly, and is convenient for the analysis after the trouble, at the same time, the system still have the strong ability and value to expand. (authors)

  13. Development of infrared communication in radiation protection and monitoring

    International Nuclear Information System (INIS)

    Thakur, Vaishali M.; Choithramani, S.J.; Sharma, D.N.; Abani, M.C.

    2003-01-01

    Infra-red communication has many important applications in instrumentation and control. Different types of nuclear instruments are used for radiation protection and surveillance program. The application of this mode of communication in these instruments helps in monitoring of inaccessible or high radiation field areas by avoiding undue exposure to the occupational worker. The demand for remotely controlled monitoring instruments and wireless data communication in the mobile computing environment has rapidly increased. This is due to the increasing need for on-line radiological data analysis with minimum human interventions, especially so if the monitoring is in hazardous environment. The wireless communication can be achieved using different communication methodology for short and long range communication. The infrared based communication is used for different applications for short range up to 9-10 meters. The use of this mode of communication has been implemented in some of the radiation monitoring instruments developed in house. The evaluation of data communication using this mode was conducted for the systems like Environmental Radiation Monitor (ERM) and results showed that data communication error is less than 0.1% up to 10 meter distance. (author)

  14. Students’ Self-Monitoring on Mathematics Ability: Cube and Cuboid Problem Solving

    Science.gov (United States)

    Lusiana, N. T.; Lukito, A.; Khabibah, S.

    2018-01-01

    This study aims at describing students’ activity to understand the behaviors processes called self-monitoring in a cube and cuboid problem solving viewed from mathematics ability. The subjects were eight graders of junior high school who studied surface area and volume of cube and cuboid clussified into high, average and low mathematics abilities. Mathematics ability test to select the subjects the study. Data were collected through self-monitoring task and interviews. Data triangulation was used to verify the credibillity findings. Data analysis was done by data condensation, data display and conclusion drawing and verification. Results showed that students’ self-monitoring with high math ability is more fullfilled self-monitoring components. Students with average and low math abilities not fullfilled the component that covers verifying the results during solving the problem. It is expected that teachers must provide different learning treatments to improve students’ self-monitoring for better learning outcomes.

  15. Assessment of service delays and impact on bed utilisation in a major teaching hospital.

    LENUS (Irish Health Repository)

    Conway, R

    2010-12-14

    BACKGROUND: Increasing economic pressures coupled with an expanding and ageing population and a hostile economic climate have led to growing interest in the optimisation of bed usage within hospitals. There are many causes for delay in a patient\\'s discharge. METHODS: This prospective observational study assessed consecutive patients admitted and discharged from hospital within a 52-day period for waiting times in the provision of requested diagnostic tests and services. RESULTS: Seventy patients were included in the study. There were median delays of 2 and 3 days for an MRI and colonoscopy, a delay of 3 days for a Holter monitor report, and 9 days for an occupational therapy referral. The median wait for consults was 1 day across all three services. CONCLUSIONS: Significant remediable delays exist during the course of many acute medical admissions. Addressing these factors will enable the provision of a faster and more cost-efficient service.

  16. 77-year-old female with syncope.

    Science.gov (United States)

    Abdelsalam, Mahmoud A; Geske, Jeffrey B

    2017-02-15

    A 77-year-old female was referred for evaluation of an episode of syncope while eating breakfast. There was no history of fall, syncope, prodrome, dyspnoea, chest discomfort or palpitations. Medical history was notable for hyperlipidaemia and treated hypertension. Blood pressure was 140/90 mm Hg, pulse 85  beats per minute (BPM). No murmurs were present on cardiac examination. ECG revealed normal sinus rhythm with left ventricular (LV) hypertrophy (see online supplementary figure S1). Holter monitor demonstrated rare premature ventricular complexes (<1% of beats), without heart block or ventricular tachycardia. Transthoracic echocardiogram is shown in figure 1. Which of the following is the explanation for the flow indicated by the yellow arrow? Aortic stenosisCoronary artery flow, indicative of coronary fistulaHypertrophic cardiomyopathy with apical pouchHypertensive heart diseaseMitral stenosis. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  17. Perioperative Rosuvastatin in Cardiac Surgery.

    Science.gov (United States)

    Zheng, Zhe; Jayaram, Raja; Jiang, Lixin; Emberson, Jonathan; Zhao, Yan; Li, Qi; Du, Juan; Guarguagli, Silvia; Hill, Michael; Chen, Zhengming; Collins, Rory; Casadei, Barbara

    2016-05-05

    Complications after cardiac surgery are common and lead to substantial increases in morbidity and mortality. Meta-analyses of small randomized trials have suggested that perioperative statin therapy can prevent some of these complications. We randomly assigned 1922 patients in sinus rhythm who were scheduled for elective cardiac surgery to receive perioperative rosuvastatin (at a dose of 20 mg daily) or placebo. The primary outcomes were postoperative atrial fibrillation within 5 days after surgery, as assessed by Holter electrocardiographic monitoring, and myocardial injury within 120 hours after surgery, as assessed by serial measurements of the cardiac troponin I concentration. Secondary outcomes included major in-hospital adverse events, duration of stay in the hospital and intensive care unit, left ventricular and renal function, and blood biomarkers. The concentrations of low-density lipoprotein cholesterol and C-reactive protein after surgery were lower in patients assigned to rosuvastatin than in those assigned to placebo (PSTICS ClinicalTrials.gov number, NCT01573143.).

  18. QT dynamics during treatment with sertindole

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Wang, Fan; Graff, Claus

    2015-01-01

    be revealed by dynamic measures of the QT interval such as the ratio of QT variability to heart rate variability (variability ratio [VR]). The aim of this study was to investigate the effect of sertindole on QT dynamics. METHODS: QTc and the VR were assessed in an observational study using 24-hour Holter...... monitoring at baseline and after 3 weeks of treatment with sertindole 16 mg. The VR was calculated by dividing the standard deviation of QT intervals with the standard deviation of heart rates. Outcome measures were compared using paired t-test. RESULTS: A total of 18 patients participated in the study, two...... were excluded from further analysis due to low amplitude of the T-wave. When patients were shifted to sertindole, the VR increased from 0.192 (SD 0.045) to 0.223 (SD 0.061), p = 0.02. The QTcF interval increased from 388 (SD 16) to 403 ms (SD 14), p = 0.002. There was no difference in heart rate 78 bpm...

  19. The impact of supraventricular ectopic complexes in different age groups and risk of recurrent atrial fibrillation after antiarrhythmic medication or catheter ablation

    DEFF Research Database (Denmark)

    Alhede, Christina; Lauridsen, Trine K; Johannessen, Arne

    2018-01-01

    INTRODUCTION: Supraventricular ectopic complexes (SVEC) are known risk factors of recurrent atrial fibrillation (AF). However, the impact of SVEC in different age groups is unknown. We aimed to investigate the risk of AF recurrence with higher SVEC burden in patients ±57years, respectively, after....... RESULTS: Age >57years were significantly associated with higher AF recurrence rate after CA (58% vs 36%, p=0.02). After CA, we observed a higher SVEC burden during follow-up in patients >57years which was not observed in the younger age group treated with CA (p=0.006). High SVEC burden at 3months after CA...... treatment with antiarrhythmic medication (AAD) or catheter ablation (CA). METHODS: In total, 260 patients with LVEF >40% and age ≤70 years were randomized to AAD (N=132) or CA (N=128) as first-line treatment for paroxysmal AF. All patients underwent 7-day Holter monitoring at baseline, and after 3, 6, 12...

  20. [Non-invasive exploration methods of supraventricular arrhythmia in current practice].

    Science.gov (United States)

    Fauchier, J P; Fauchier, L; Babuty, D; Sirinelli, A; Cosnay, P

    1993-06-15

    In patients with supraventricular rhythm disorders ambulatory electro-cardiographic recording (Holter system) is an indispensable examination as it detects attacks that pass unrecorded by conventional ECG, being asymptomatic, too brief or too rare. It confirms the diagnosis, defines the factors triggering the attacks, detects the association of rhythm and conduction disorders, guides the treatment and monitors its effectiveness. Sequential ambulatory recording lends itself particularly well to this last objective. Biochemical examinations explain the cause of certain relapses (potassium depletion, high alcohol blood level) or detect the origin, clinically more or less obvious, of these disorders of rhythm (essays of thyroid hormones). Measuring blood levels of therapeutic drugs makes the handling of these various drugs safer. Finally, echocardiography detects an underlying heart disease, evaluates the size of the left atrium (a factor of relapse when it is dilated and of embolism when it harbours thrombi) and assesses the left ventricular function before administration of antiarrhythmics which, to varying extents, are all negative inotropic drugs.

  1. Cryptogenic embolic stroke in a girl with a trisomy 21 mosaic.

    Science.gov (United States)

    Stöllberger, Claudia; Weiss, Simone; Zlabinger, Gerhard; Finsterer, Josef

    2012-06-01

    Stroke in trisomy 21 may be due to cardioembolism, atherosclerosis, vasculitis, moyamoya disease, sinus venous thrombosis, internal carotid hypoplasia or infections like endocarditis with septic emboli, meningitis or brain abscess. In rare cases, however, stroke etiology remains unexplained. We present a 19 year old Caucasian girl with trisomy 21 with a 47XX+21 karyotype who suffered at age 11 years from a transient ischemic attack with left hemiparesis, and at age 17 years from an ischemic stroke in the territory of the right cerebral medial artery. She suffered from arterial hypertension, obesity and hypercholesterolemia. Since blood coagulation studies, immunologic parameters, blood cultures, 24-h Holter monitoring, transthoracic and transesophageal echocardiography, magnetic resonance angiography of the extra- and intracranial vessels, thoracic and abdominal aorta and renal arteries did not provide any explanation for the stroke, implantation of a loop recorder is considered in order to detect episodes of clinically silent atrial fibrillation.

  2. Exercise training improves autonomic profiles in patients with Charcot-Marie-Tooth disease.

    Science.gov (United States)

    El Mhandi, Lhassan; Pichot, Vincent; Calmels, Paul; Gautheron, Vincent; Roche, Frédéric; Féasson, Léonard

    2011-11-01

    The effect of an interval exercise training (ITE) program on heart rate variability (HRV) was studied in 8 patients with Charcot-Marie-Tooth (CMT) disease and 8 healthy controls. At baseline, all subjects underwent ambulatory 24-hour Holter electrocardiographic (ECG) monitoring to evaluate HRV. HRV analysis was repeated on CMT patients after they completed a 24-week ITE program on a cycle ergometer. Before exercise, all HRV indices were lower in patients compared with controls, and the difference reached statistical significance for pNN50 (percent of differences between adjacent R-R intervals exceeding 50 ms). After ITE, time- and frequency-domain indices were significantly improved, particularly at night (+8% mean R-R interval, +95% pNN50, 52% reduction in low/high-frequency ratio). We observed significant increases in some of the time and frequency parameters, and values sometimes exceeded those of controls at baseline. Our results suggest that ITE improves HRV modulation in CMT patients by enhancing parasympathetic activity. Copyright © 2011 Wiley Periodicals, Inc.

  3. Evaluation of a dietary targets monitor.

    Science.gov (United States)

    Lean, M E J; Anderson, A S; Morrison, C; Currall, J

    2003-05-01

    To evaluate a two-page food frequency list for use as a Dietary Targets Monitor in large scale surveys to quantify consumptions of the key foods groups targeted in health promotion. Intakes of fruit and vegetables, starchy foods and fish estimated from a validated food frequency questionnaire (FFQ) were compared with a short food frequency list (the Dietary Targets Monitor) specifically designed to assess habitual frequency of consumption of foods in relation to dietary targets which form the basis of a National (Scottish) Food and Health Policy. A total of 1085 adults aged 25-64 y from the Glasgow MONICA Study. : The two questionnaires both collected data on frequencies of food consumption for fruit and vegetables, starchy foods and fish. Comparing the two questionnaires, there were consistent biases, best expressed as ratios (FFQ:Dietary Targets Monitor) between the methods for fruit and vegetables (1.33, 95% CI 1.29, 1.38) and 'starchy foods' (1.08, 95% CI 1.05, 1.12), the DTM showing systematic under-reporting by men. For fish consumption, there was essentially no bias between the methods (0.99, 95% CI 0.94, 1.03). Using calibration factors to adjust for biases, the Dietary Targets Monitor indicated that 16% of the subjects were achieving the Scottish Diet food target (400 g/day) for fruit and vegetable consumption. Nearly one-third (32%) of the subjects were eating the recommended intakes of fish (three portions per week). The Dietary Targets Monitor measure of starchy foods consumption was calibrated using FFQ data to be able to make quantitative estimates: 20% of subjects were eating six or more portions of starchy food daily. A similar estimation of total fat intake and saturated fat intake (g/day) allowed the categorization of subjects as low, moderate or high fat consumers, with broad agreement between the methods. The levels of agreement demonstrated by Bland-Altman analysis, were insufficient to permit use of the adjusted DTM to estimate quantitative

  4. Results of monitoring at Olkiluoto in 2012. Environment

    International Nuclear Information System (INIS)

    Haapanen, A.

    2014-04-01

    In 2003, Posiva Oy presented a programme for monitoring at Olkiluoto during construction and operation of ONKALO. In 2012 the monitoring programme was updated to concern the years 2012-2018. Part of the monitoring is performed by the company running the nuclear power plants on the island, Teollisuuden Voima Oy (TVO). This Working Report presents the main results of Posiva's environmental monitoring programme on Olkiluoto Island in 2012. Results are presented under five topics: 1. Evolution of geosphere, 2. Biosphere modelling input data, 3. Interaction between surface environment and groundwater in bedrock, 4. Environmental impact and 5. Baseline of monitoring of radioactive releases. Concerning the evolution of geosphere, LIDAR-scannings were done in the Olkiluoto area in 2012. The acquired data can be used for elevation and other modelling purposes. The soil solution quality in 2012 was quite comparable to that in earlier years. Proximity of the sea and the young age of soils are seen in soil solution results. Biosphere modelling input data in 2012 included e.g. continuous tree litterfall and transpiration data, as well as updated game statistics and population estimates of fauna, a fishery survey from the River Eurajoki (2011) and basic monitoring data from Olkiluoto offshore properties. Interaction between surface environment and groundwater in bedrock includes e.g. weather and surface water monitoring data. Environmental impact analyses included e.g. monitoring of noise, air quality, effluent waters and private drilled wells. Noise monitoring in the vicinity of ONKALO showed that in the case of raised noise levels the sources are mainly the traffic on Olkiluodontie road, the air conditioning of ONKALO and occasional sources such as springtime bird sounds. Construction activities in the area were seen in increased amount of NO 3 -N in the bulk deposition, and Al and Fe accumulating on needle surfaces in areas close to the rock piling and crushing area. Scots

  5. Results of monitoring at Olkiluoto in 2012. Environment

    Energy Technology Data Exchange (ETDEWEB)

    Haapanen, A. (ed.) [Haapanen Forest Consulting, Vanhakylae (Finland)

    2014-04-15

    In 2003, Posiva Oy presented a programme for monitoring at Olkiluoto during construction and operation of ONKALO. In 2012 the monitoring programme was updated to concern the years 2012-2018. Part of the monitoring is performed by the company running the nuclear power plants on the island, Teollisuuden Voima Oy (TVO). This Working Report presents the main results of Posiva's environmental monitoring programme on Olkiluoto Island in 2012. Results are presented under five topics: 1. Evolution of geosphere, 2. Biosphere modelling input data, 3. Interaction between surface environment and groundwater in bedrock, 4. Environmental impact and 5. Baseline of monitoring of radioactive releases. Concerning the evolution of geosphere, LIDAR-scannings were done in the Olkiluoto area in 2012. The acquired data can be used for elevation and other modelling purposes. The soil solution quality in 2012 was quite comparable to that in earlier years. Proximity of the sea and the young age of soils are seen in soil solution results. Biosphere modelling input data in 2012 included e.g. continuous tree litterfall and transpiration data, as well as updated game statistics and population estimates of fauna, a fishery survey from the River Eurajoki (2011) and basic monitoring data from Olkiluoto offshore properties. Interaction between surface environment and groundwater in bedrock includes e.g. weather and surface water monitoring data. Environmental impact analyses included e.g. monitoring of noise, air quality, effluent waters and private drilled wells. Noise monitoring in the vicinity of ONKALO showed that in the case of raised noise levels the sources are mainly the traffic on Olkiluodontie road, the air conditioning of ONKALO and occasional sources such as springtime bird sounds. Construction activities in the area were seen in increased amount of NO{sub 3}-N in the bulk deposition, and Al and Fe accumulating on needle surfaces in areas close to the rock piling and crushing area

  6. Map showing areas of visible land disturbances caused by two military training operations in the Mojave Desert, California

    Science.gov (United States)

    Prose, D.V.

    1986-01-01

    This map shows areas that retain visible land disturbances produced during two military armored-vehicle training operations in the Mojave Desert, California. The map documents the lasting visual effects these operations have on this arid region and provides a data base for monitoring changes in the extent of visual disturbances in the future.

  7. Surfzone monitoring using rotary wing unmanned aerial vehicles

    NARCIS (Netherlands)

    Brouwer, R.L.; De Schipper, M.A.; Rynne, P.F.; Graham, F.J.; Reniers, A.J.H.M.; Macmahan, J.H.

    2015-01-01

    This study investigates the potential of rotary wing unmanned aerial vehicles (UAVs) to monitor the surfzone. This paper shows that these UAVs are extremely flexible surveying platforms that can gather nearcontinuous moderate spatial resolution and high temporal resolution imagery from a fixed

  8. Testing an innovative framework for flood forecasting, monitoring and mapping in Europe

    Science.gov (United States)

    Dottori, Francesco; Kalas, Milan; Lorini, Valerio; Wania, Annett; Pappenberger, Florian; Salamon, Peter; Ramos, Maria Helena; Cloke, Hannah; Castillo, Carlos

    2017-04-01

    Between May and June 2016, France was hit by severe floods, particularly in the Loire and Seine river basins. In this work, we use this case study to test an innovative framework for flood forecasting, mapping and monitoring. More in detail, the system integrates in real-time two components of the Copernicus Emergency mapping services, namely the European Flood Awareness System and the satellite-based Rapid Mapping, with new procedures for rapid risk assessment and social media and news monitoring. We explore in detail the performance of each component of the system, demonstrating the improvements in respect to stand-alone flood forecasting and monitoring systems. We show how the performances of the forecasting component can be refined using the real-time feedback from social media monitoring to identify which areas were flooded, to evaluate the flood intensity, and therefore to correct impact estimations. Moreover, we show how the integration with impact forecast and social media monitoring can improve the timeliness and efficiency of satellite based emergency mapping, and reduce the chances of missing areas where flooding is already happening. These results illustrate how the new integrated approach leads to a better and earlier decision making and a timely evaluation of impacts.

  9. Chapter 7. Monitoring of chemical contamination of the environment and analytical-chemical monitoring

    International Nuclear Information System (INIS)

    Sojak, L.

    2006-01-01

    This chapter deals with the monitoring of chemical contamination of the environment and analytical-chemical monitoring. There are presented: the concept o monitoring of the environment of the Slovak Republic; unified monitoring system and complex information about state and development of the environment; analytical methods determination of chemical contaminants in the environment

  10. Personnel monitoring

    International Nuclear Information System (INIS)

    1965-01-01

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  11. Personnel monitoring

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1966-12-31

    This film stresses the need for personnel monitoring in work areas where there is a hazard of exposure to radiation. It illustrates the use of personnel monitoring devices (specially the film dosimeter), the assessment of exposure to radiation and the detailed recording of the results on personnel filing cards

  12. Power consumption monitoring using additional monitoring device

    Energy Technology Data Exchange (ETDEWEB)

    Truşcă, M. R. C., E-mail: radu.trusca@itim-cj.ro; Albert, Ş., E-mail: radu.trusca@itim-cj.ro; Tudoran, C., E-mail: radu.trusca@itim-cj.ro; Soran, M. L., E-mail: radu.trusca@itim-cj.ro; Fărcaş, F., E-mail: radu.trusca@itim-cj.ro [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Abrudean, M. [Technical University of Cluj-Napoca, Cluj-Napoca (Romania)

    2013-11-13

    Today, emphasis is placed on reducing power consumption. Computers are large consumers; therefore it is important to know the total consumption of computing systems. Since their optimal functioning requires quite strict environmental conditions, without much variation in temperature and humidity, reducing energy consumption cannot be made without monitoring environmental parameters. Thus, the present work uses a multifunctional electric meter UPT 210 for power consumption monitoring. Two applications were developed: software which carries meter readings provided by electronic and programming facilitates remote device and a device for temperature monitoring and control. Following temperature variations that occur both in the cooling system, as well as the ambient, can reduce energy consumption. For this purpose, some air conditioning units or some computers are stopped in different time slots. These intervals were set so that the economy is high, but the work's Datacenter is not disturbed.

  13. Quaternion Based Thermal Condition Monitoring System

    Science.gov (United States)

    Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee

    In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.

  14. Self-Monitoring Using Continuous Glucose Monitors with Real-Time Feedback Improves Exercise Adherence in Individuals with Impaired Blood Glucose: A Pilot Study.

    Science.gov (United States)

    Bailey, Kaitlyn J; Little, Jonathan P; Jung, Mary E

    2016-03-01

    Exercise helps individuals with prediabetes or type 2 diabetes (T2D) manage their blood glucose (BG); however, exercise adherence in this population is dismal. In this pilot study we tested the efficacy of a self-monitoring group-based intervention using continuous glucose monitors (CGMs) at increasing exercise adherence in individuals with impaired BG. Thirteen participants with prediabetes or T2D were randomized to an 8-week standard care exercise program (CON condition) (n = 7) or self-monitoring exercise intervention (SM condition) (n = 6). Participants in the SM condition were taught how to self-monitor their exercise and BG, to goal set, and to use CGM to observe how exercise influences BG. We hypothesized that compared with the CON condition, using a real-time CGM would facilitate self-monitoring behavior, resulting in increased exercise adherence. Repeated-measures analysis of variance revealed significant Condition × Time interactions for self-monitoring (P goal setting (P = 0.01), and self-efficacy to self-monitor (P = 0.01), such that the SM condition showed greater increases in these outcomes immediately after the program and at the 1-month follow-up compared with the CON condition. The SM condition had higher program attendance rates (P = 0.03), and a greater proportion of participants reregistered for additional exercise programs (P = 0.048) compared with the CON condition. Participants in both conditions experienced improvements in health-related quality of life, waist circumference, and fitness (P values exercise behavior in individuals living with prediabetes or T2D.

  15. Global nuclear material monitoring with NDA and C/S data through integrated facility monitoring

    International Nuclear Information System (INIS)

    Howell, J.A.; Menlove, H.O.; Argo, P.; Goulding, C.; Klosterbuer, S.; Halbig, J.

    1996-01-01

    This paper focuses on a flexible, integrated demonstration of a monitoring approach for nuclear material monitoring. This includes aspects of item signature identification, perimeter portal monitoring, advanced data analysis, and communication as a part of an unattended continuous monitoring system in an operating nuclear facility. Advanced analysis is applied to the integrated nondestructive assay and containment and surveillance data that are synchronized in time. End result will be the foundation for a cost-effective monitoring system that could provide the necessary transparency even in areas that are denied to foreign nationals of both US and Russia should these processes and materials come under full-scope safeguards or bilateral agreements. Monitoring systems of this kind have the potential to provide additional benefits including improved nuclear facility security and safeguards and lower personnel radiation exposures. Demonstration facilities in this paper include VTRAP-prototype, Los Alamos Critical Assemblies Facility, Kazakhstan BM-350 Reactor monitor, DUPIC radiation monitoring, and JOYO and MONJU radiation monitoring

  16. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  17. Integrated environmental monitoring -- prototype demonstration

    International Nuclear Information System (INIS)

    Bryce, R.W.; Vail, L.W.; Hostetler, D.D.; Meyer, P.D.; Carlson, T.J.; Miller, P.L.

    1994-01-01

    Groundwater monitoring is an important activity at US Department of Energy (DOE) sites. Monitoring programs at DOE facilities have evolved in response to operational needs at the facilities, public outcries for information, regulatory requirements, DOE orders, and improvements in monitoring technology. Decisions regarding sampling location, sampling frequency, analyses performed, and other aspects of monitoring network design can have major implications for detecting releases and for making subsequent higher level decisions about facility operation and remediation. The Integrated Environmental Monitoring (IEM) concept is a set of analytical procedures and software tools that can be used to improve monitoring network design decisions. Such decisions include the choice of monitoring locations, sampling frequencies, sensor technologies, and monitored constituents. IEM provides a set of monitoring alternatives that balance the tradeoffs between competing monitoring objectives such as the minimization of cost and the minimization of uncertainty. The alternatives provided are the best available with respect to the monitoring objectives, consistent with the physical and chemical characteristics of the site, and consist with applicable regulatory requirements. The selection of the best monitoring alternative to implement is made by the stakeholders after reviewing the alternatives and tradeoffs produced by the IEM process

  18. Integrating statistical machine learning in a semantic sensor web for proactive monitoring and control

    CSIR Research Space (South Africa)

    Adeleke, Jude Adekunle

    2017-04-01

    Full Text Available in an indoor air quality monitoring case study. A sliding window approach that employs the Multilayer Perceptron model to predict short term PM 2 . 5 pollution situations is integrated into the proactive monitoring and control framework. Results show...

  19. A component-based system for agricultural drought monitoring by remote sensing.

    Science.gov (United States)

    Dong, Heng; Li, Jun; Yuan, Yanbin; You, Lin; Chen, Chao

    2017-01-01

    In recent decades, various kinds of remote sensing-based drought indexes have been proposed and widely used in the field of drought monitoring. However, the drought-related software and platform development lag behind the theoretical research. The current drought monitoring systems focus mainly on information management and publishing, and cannot implement professional drought monitoring or parameter inversion modelling, especially the models based on multi-dimensional feature space. In view of the above problems, this paper aims at fixing this gap with a component-based system named RSDMS to facilitate the application of drought monitoring by remote sensing. The system is designed and developed based on Component Object Model (COM) to ensure the flexibility and extendibility of modules. RSDMS realizes general image-related functions such as data management, image display, spatial reference management, image processing and analysis, and further provides drought monitoring and evaluation functions based on internal and external models. Finally, China's Ningxia region is selected as the study area to validate the performance of RSDMS. The experimental results show that RSDMS provide an efficient and scalable support to agricultural drought monitoring.

  20. Spectral Analysis Related to Bare-Metal and Drug-Eluting Coronary Stent Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rose Mary Ferreira Lisboa da, E-mail: roselisboa@cardiol.br [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Silva, Carlos Augusto Bueno [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil); Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Greco, Otaviano José [Belo Horizonte, Hospital São João de Deus, Divinópolis, MG (Brazil); Moreira, Maria da Consolação Vieira [Faculdade de Medicina da UFMG, Divinópolis, MG (Brazil)

    2014-08-15

    The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

  1. The implementation of quantitative electromyographic neuromuscular monitoring in an academic anesthesia department.

    Science.gov (United States)

    Todd, Michael M; Hindman, Bradley J; King, Brian J

    2014-08-01

    Although experts agree on the importance of quantitative neuromuscular blockade monitoring, particularly for managing reversal, such monitoring is not in widespread use. We describe the processes and results of our departmental experience with the introduction of such quantitative monitoring. In mid-2010, the senior authors became concerned about the management of nondepolarizing neuromuscular blockers (NMB) by providers within the department, based on personal observations and on a review of a departmental quality assurance/adverse event database. This review indicated the occurrence of 2 to 4 reintubations/year in the postanesthesia care unit (PACU) that were deemed to be probably or possibly related to inadequate reversal. In response, quantitative blockade equipment (Datex-Omeda ElectroSensor™ EMG system) was installed in all our main operating rooms in January 2011. This introduction was accompanied by an extensive educational effort. Adoption of the system was slow; by mid-2011, the quantitative system was being used in system. In the initial (August 2011) PACU survey of 96 patients receiving nondepolarizing NMBs, 31% had a TOF ratio of ≤0.9, 17% had a ratio of ≤0.8, and 4 patients (4%) had ratios of ≤0.5. A record review showed that the quantitative monitoring system had been used to monitor reversal in only 51% of these patients, and 23% of patients had no evidence of any monitoring, including qualitative TOF assessment. By December of 2012 (after 2 interim PACU monitoring surveys), a fourth survey showed 15% of 101 monitored patients had a TOF ratio ≤0.9, and only 5% had ratios ≤0.8. (P system was present in 83% of cases (P < 0.05 vs August 2011). A final survey in July 2013 showed nearly identical values to those from December 2012. The lowest TOF ratio observed in any patient not receiving a nondepolarizing NMB was 0.92. There were no changes in the patterns of either rocuronium or neostigmine use over the duration of the project (through

  2. Source Monitoring in Alzheimer's Disease

    Science.gov (United States)

    El Haj, Mohamad; Fasotti, Luciano; Allain, Philippe

    2012-01-01

    Source monitoring is the process of making judgments about the origin of memories. There are three categories of source monitoring: reality monitoring (discrimination between self- versus other-generated sources), external monitoring (discrimination between several external sources), and internal monitoring (discrimination between two types of…

  3. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System.

    Science.gov (United States)

    Kwon, Sungjun; Lee, Dongseok; Kim, Jeehoon; Lee, Youngki; Kang, Seungwoo; Seo, Sangwon; Park, Kwangsuk

    2016-03-11

    In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG) monitoring system, Sinabro, which monitors a user's ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR) and heart rate variability (HRV), to support the pervasive healthcare apps for smartphones based on the user's high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1) upgrading the sensor device; (2) improving the feature extraction process; and (3) evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user's daily smartphone use.

  4. Sinabro: A Smartphone-Integrated Opportunistic Electrocardiogram Monitoring System

    Directory of Open Access Journals (Sweden)

    Sungjun Kwon

    2016-03-01

    Full Text Available In our preliminary study, we proposed a smartphone-integrated, unobtrusive electrocardiogram (ECG monitoring system, Sinabro, which monitors a user’s ECG opportunistically during daily smartphone use without explicit user intervention. The proposed system also monitors ECG-derived features, such as heart rate (HR and heart rate variability (HRV, to support the pervasive healthcare apps for smartphones based on the user’s high-level contexts, such as stress and affective state levels. In this study, we have extended the Sinabro system by: (1 upgrading the sensor device; (2 improving the feature extraction process; and (3 evaluating extensions of the system. We evaluated these extensions with a good set of algorithm parameters that were suggested based on empirical analyses. The results showed that the system could capture ECG reliably and extract highly accurate ECG-derived features with a reasonable rate of data drop during the user’s daily smartphone use.

  5. Detection and Processing Techniques of FECG Signal for Fetal Monitoring

    Directory of Open Access Journals (Sweden)

    Hasan MA

    2009-03-01

    Full Text Available Abstract Fetal electrocardiogram (FECG signal contains potentially precise information that could assist clinicians in making more appropriate and timely decisions during labor. The ultimate reason for the interest in FECG signal analysis is in clinical diagnosis and biomedical applications. The extraction and detection of the FECG signal from composite abdominal signals with powerful and advance methodologies are becoming very important requirements in fetal monitoring. The purpose of this review paper is to illustrate the various methodologies and developed algorithms on FECG signal detection and analysis to provide efficient and effective ways of understanding the FECG signal and its nature for fetal monitoring. A comparative study has been carried out to show the performance and accuracy of various methods of FECG signal analysis for fetal monitoring. Finally, this paper further focused some of the hardware implementations using electrical signals for monitoring the fetal heart rate. This paper opens up a passage for researchers, physicians, and end users to advocate an excellent understanding of FECG signal and its analysis procedures for fetal heart rate monitoring system.

  6. A high arctic experience of uniting research and monitoring

    Science.gov (United States)

    Schmidt, Niels Martin; Christensen, Torben R.; Roslin, Tomas

    2017-07-01

    Monitoring is science keeping our thumb on the pulse of the environment to detect any changes of concern for societies. Basic science is the question-driven search for fundamental processes and mechanisms. Given the firm root of monitoring in human interests and needs, basic sciences have often been regarded as scientifically "purer"—particularly within university-based research communities. We argue that the dichotomy between "research" and "monitoring" is an artificial one, and that this artificial split clouds the definition of scientific goals and leads to suboptimal use of resources. We claim that the synergy between the two scientific approaches is well distilled by science conducted under extreme logistic constraints, when scientists are forced to take full advantage of both the data and the infrastructure available. In evidence of this view, we present our experiences from two decades of uniting research and monitoring at the remote research facility Zackenberg in High Arctic Greenland. For this site, we show how the combination of insights from monitoring with the mechanistic understanding obtained from basic research has yielded the most complete understanding of the system—to the benefit of all, and as an example to follow. We therefore urge scientists from across the continuum from monitoring to research to come together, to disregard old division lines, and to work together to expose a comprehensive picture of ecosystem change and its consequences.

  7. First-year experience with the ATLAS online monitoring framework

    International Nuclear Information System (INIS)

    Corso-Radu, A

    2010-01-01

    ATLAS is one of the four experiments in the Large Hadron Collider (LHC) at CERN, which has been put in operation this year. The challenging experimental environment and the extreme detector complexity required development of a highly scalable distributed monitoring framework, which is currently being used to monitor the quality of the data being taken as well as operational conditions of the hardware and software elements of the detector, trigger and data acquisition systems. At the moment the ATLAS Trigger/DAQ system is distributed over more than 1000 computers, which is about one third of the final ATLAS size. At every minute of an ATLAS data taking session the monitoring framework serves several thousands physics events to monitoring data analysis applications, handles more than 4 million histograms updates coming from more than 4 thousands applications, executes 10 thousands advanced data quality checks for a subset of those histograms, displays histograms and results of these checks on several dozens of monitors installed in main and satellite ATLAS control rooms. This note presents the overview of the online monitoring software framework, and describes the experience, which was gained during an extensive commissioning period as well as at the first phase of LHC beam in September 2008. Performance results, obtained on the current ATLAS DAQ system will also be presented, showing that the performance of the framework is adequate for the final ATLAS system.

  8. The critical role of volcano monitoring in risk reduction

    Directory of Open Access Journals (Sweden)

    R. I. Tilling

    2008-01-01

    Full Text Available Data from volcano-monitoring studies constitute the only scientifically valid basis for short-term forecasts of a future eruption, or of possible changes during an ongoing eruption. Thus, in any effective hazards-mitigation program, a basic strategy in reducing volcano risk is the initiation or augmentation of volcano monitoring at historically active volcanoes and also at geologically young, but presently dormant, volcanoes with potential for reactivation. Beginning with the 1980s, substantial progress in volcano-monitoring techniques and networks – ground-based as well space-based – has been achieved. Although some geochemical monitoring techniques (e.g., remote measurement of volcanic gas emissions are being increasingly applied and show considerable promise, seismic and geodetic methods to date remain the techniques of choice and are the most widely used. Availability of comprehensive volcano-monitoring data was a decisive factor in the successful scientific and governmental responses to the reawakening of Mount St. elens (Washington, USA in 1980 and, more recently, to the powerful explosive eruptions at Mount Pinatubo (Luzon, Philippines in 1991. However, even with the ever-improving state-of-the-art in volcano monitoring and predictive capability, the Mount St. Helens and Pinatubo case histories unfortunately still represent the exceptions, rather than the rule, in successfully forecasting the most likely outcome of volcano unrest.

  9. Operational satellites and the global monitoring of snow and ice

    Science.gov (United States)

    Walsh, John E.

    1991-01-01

    The altitudinal dependence of the global warming projected by global climate models is at least partially attributable to the albedo-temperature feedback involving snow and ice, which must be regarded as key variables in the monitoring for global change. Statistical analyses of data from IR and microwave sensors monitoring the areal coverage and extent of sea ice have led to mixed conclusions about recent trends of hemisphere sea ice coverage. Seasonal snow cover has been mapped for over 20 years by NOAA/NESDIS on the basis of imagery from a variety of satellite sensors. Multichannel passive microwave data show some promise for the routine monitoring of snow depth over unforested land areas.

  10. Development and implementation of a PV performance monitoring system based on inverter measurements

    DEFF Research Database (Denmark)

    Spataru, Sergiu; Gavriluta, Anamaria Florina; Maaløe, Lars

    2016-01-01

    Performance monitoring and fault detection systems have become necessary for decreasing operation and maintenance cost in large photovoltaic (PV) plants, as well for maximizing plan yield and lifetime. We expect a similar development for residential and commercial PV system applications, where...... the inverter’s own monitoring and communication capabilities. We also aim to lower the implementation cost, by using a simple, but accurate performance monitoring approach, and show the practical issues that can arise when implementing such a system....

  11. Application of GPRS and GIS in Boiler Remote Monitoring System

    OpenAIRE

    Hongchao Wang; Yifeng Wu

    2012-01-01

    Application of GPRS and GIS in boiler remote monitoring system was designed in this paper by combining the advantage of GPRS and GIS in remote data transmission with configuration monitoring technology. The detail information of the operating conditions of the industrial boiler can be viewed by marking the location of boiler on the electronic map dynamically which can realize the unified management for industrial boiler of a region or city conveniently. Experimental application show that the ...

  12. Keeping your distance: attentional withdrawal in individuals who show physiological signs of social discomfort.

    Science.gov (United States)

    Szpak, Ancret; Loetscher, Tobias; Churches, Owen; Thomas, Nicole A; Spence, Charles J; Nicholls, Michael E R

    2015-04-01

    Being in close social proximity to a stranger is generally perceived to be an uncomfortable experience, which most people seek to avoid. In circumstances where crowding is unavoidable, however, people may seek to withdraw their attention from the other person. This study examined whether social discomfort, as indexed by electrodermal activity, is related to a withdrawal of attention in 28 (m=8, f=20) university students. Students performed a radial line bisection task while alone or together with a stranger facing them. Physiological arousal was indexed by a wrist monitor, which recorded electrodermal activity. Correlational analyses showed that individuals who displayed physiological discomfort when together showed a withdrawal of the perceived midpoint of the line towards them (and away from the stranger). Conversely, individuals who showed no discomfort exhibited an expansion of the perceived midpoint away from them. We propose that participants shift their attention away from the stranger to increase interpersonal distance and reduce anxiety/arousal. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Multimodal evidence of regional midcingulate gray matter volume underlying conflict monitoring

    Science.gov (United States)

    Parvaz, Muhammad A.; Maloney, Thomas; Moeller, Scott J.; Malaker, Pias; Konova, Anna B.; Alia-Klein, Nelly; Goldstein, Rita Z.

    2014-01-01

    Functional neuroimaging studies have long implicated the mid-cingulate cortex (MCC) in conflict monitoring, but it is not clear whether its structural integrity (i.e., the gray matter volume) influences its conflict monitoring function. In this multimodal study, we used T1-weighted MRI scans as well as event-related potentials (ERPs) to test whether the MCC gray matter volume is associated with the electrocortical marker (i.e., No-go N200 ERP component) of conflict monitoring in healthy individuals. The specificity of such a relationship in health was determined in two ways: by (A) acquiring the same data from individuals with cocaine use disorder (CUD), known to have deficits in executive function including behavioral monitoring; and (B) acquiring the P300 ERP component that is linked with attention allocation and not specifically with conflict monitoring. Twenty-five (39.1 ± 8.4 years; 8 females) healthy individuals and 25 (42.7 ± 5.9 years; 6 females) individuals with CUD underwent a rewarded Go/No-go task during which the ERP data was collected, and they also underwent a structural MRI scan. The whole brain regression analysis showed a significant correlation between MCC structural integrity and the well-known ERP measure of conflict monitoring (N200, but not the P300) in healthy individuals, which was absent in CUD who were characterized by reduced MCC gray matter volume, N200 abnormalities as well as reduced task accuracy. In individuals with CUD instead, the N200 amplitude was associated with drug addiction symptomatology. These results show that the integrity of MCC volume is directly associated with the electrocortical correlates of conflict monitoring in healthy individuals, and such an association breaks down in psychopathologies that impact these brain processes. Taken together, this MCC–N200 association may serve as a biomarker of improved behavioral monitoring processes in diseased populations. PMID:24918068

  14. Multimodal evidence of regional midcingulate gray matter volume underlying conflict monitoring

    Directory of Open Access Journals (Sweden)

    Muhammad A. Parvaz

    2014-01-01

    Full Text Available Functional neuroimaging studies have long implicated the mid-cingulate cortex (MCC in conflict monitoring, but it is not clear whether its structural integrity (i.e., the gray matter volume influences its conflict monitoring function. In this multimodal study, we used T1-weighted MRI scans as well as event-related potentials (ERPs to test whether the MCC gray matter volume is associated with the electrocortical marker (i.e., No-go N200 ERP component of conflict monitoring in healthy individuals. The specificity of such a relationship in health was determined in two ways: by (A acquiring the same data from individuals with cocaine use disorder (CUD, known to have deficits in executive function including behavioral monitoring; and (B acquiring the P300 ERP component that is linked with attention allocation and not specifically with conflict monitoring. Twenty-five (39.1 ± 8.4 years; 8 females healthy individuals and 25 (42.7 ± 5.9 years; 6 females individuals with CUD underwent a rewarded Go/No-go task during which the ERP data was collected, and they also underwent a structural MRI scan. The whole brain regression analysis showed a significant correlation between MCC structural integrity and the well-known ERP measure of conflict monitoring (N200, but not the P300 in healthy individuals, which was absent in CUD who were characterized by reduced MCC gray matter volume, N200 abnormalities as well as reduced task accuracy. In individuals with CUD instead, the N200 amplitude was associated with drug addiction symptomatology. These results show that the integrity of MCC volume is directly associated with the electrocortical correlates of conflict monitoring in healthy individuals, and such an association breaks down in psychopathologies that impact these brain processes. Taken together, this MCC–N200 association may serve as a biomarker of improved behavioral monitoring processes in diseased populations.

  15. Multimodal evidence of regional midcingulate gray matter volume underlying conflict monitoring.

    Science.gov (United States)

    Parvaz, Muhammad A; Maloney, Thomas; Moeller, Scott J; Malaker, Pias; Konova, Anna B; Alia-Klein, Nelly; Goldstein, Rita Z

    2014-01-01

    Functional neuroimaging studies have long implicated the mid-cingulate cortex (MCC) in conflict monitoring, but it is not clear whether its structural integrity (i.e., the gray matter volume) influences its conflict monitoring function. In this multimodal study, we used T1-weighted MRI scans as well as event-related potentials (ERPs) to test whether the MCC gray matter volume is associated with the electrocortical marker (i.e., No-go N200 ERP component) of conflict monitoring in healthy individuals. The specificity of such a relationship in health was determined in two ways: by (A) acquiring the same data from individuals with cocaine use disorder (CUD), known to have deficits in executive function including behavioral monitoring; and (B) acquiring the P300 ERP component that is linked with attention allocation and not specifically with conflict monitoring. Twenty-five (39.1 ± 8.4 years; 8 females) healthy individuals and 25 (42.7 ± 5.9 years; 6 females) individuals with CUD underwent a rewarded Go/No-go task during which the ERP data was collected, and they also underwent a structural MRI scan. The whole brain regression analysis showed a significant correlation between MCC structural integrity and the well-known ERP measure of conflict monitoring (N200, but not the P300) in healthy individuals, which was absent in CUD who were characterized by reduced MCC gray matter volume, N200 abnormalities as well as reduced task accuracy. In individuals with CUD instead, the N200 amplitude was associated with drug addiction symptomatology. These results show that the integrity of MCC volume is directly associated with the electrocortical correlates of conflict monitoring in healthy individuals, and such an association breaks down in psychopathologies that impact these brain processes. Taken together, this MCC-N200 association may serve as a biomarker of improved behavioral monitoring processes in diseased populations.

  16. A Security Monitoring Method Based on Autonomic Computing for the Cloud Platform

    Directory of Open Access Journals (Sweden)

    Jingjie Zhang

    2018-01-01

    Full Text Available With the continuous development of cloud computing, cloud security has become one of the most important issues in cloud computing. For example, data stored in the cloud platform may be attacked, and its security is difficult to be guaranteed. Therefore, we must attach weight to the issue of how to protect the data stored in the cloud. To protect data, data monitoring is a necessary process. Based on autonomic computing, we develop a cloud data monitoring system on the cloud platform, monitoring whether the data is abnormal in the cycle and analyzing the security of the data according to the monitored results. In this paper, the feasibility of the scheme can be verified through simulation. The results show that the proposed method can adapt to the dynamic change of cloud platform load, and it can also accurately evaluate the degree of abnormal data. Meanwhile, by adjusting monitoring frequency automatically, it improves the accuracy and timeliness of monitoring. Furthermore, it can reduce the monitoring cost of the system in normal operation process.

  17. Exploring a New Security Framework for Remote Patient Monitoring Devices

    Directory of Open Access Journals (Sweden)

    Brian Ondiege

    2017-02-01

    Full Text Available Security has been an issue of contention in healthcare. The lack of familiarity and poor implementation of security in healthcare leave the patients’ data vulnerable to attackers. The main issue is assessing how we can provide security in an RPM infrastructure. The findings in literature show there is little empirical evidence on proper implementation of security. Therefore, there is an urgent need in addressing cybersecurity issues in medical devices. Through the review of relevant literature in remote patient monitoring and use of a Microsoft threat modelling tool, we identify and explore current vulnerabilities and threats in IEEE 11073 standard devices to propose a new security framework for remote patient monitoring devices. Additionally, current RPM devices have a limitation on the number of people who can share a single device, therefore, we propose the use of NFC for identification in Remote Patient Monitoring (RPM devices for multi-user environments where we have multiple people sharing a single device to reduce errors associated with incorrect user identification. We finally show how several techniques have been used to build the proposed framework.

  18. SEP Montage Variability Comparison during Intraoperative Neurophysiologic Monitoring.

    Science.gov (United States)

    Hanson, Christine; Lolis, Athena Maria; Beric, Aleksandar

    2016-01-01

    Intraoperative monitoring is performed to provide real-time assessment of the neural structures that can be at risk during spinal surgery. Somatosensory evoked potentials (SEPs) are the most commonly used modality for intraoperative monitoring. SEP stability can be affected by many factors during the surgery. This study is a prospective review of SEP recordings obtained during intraoperative monitoring of instrumented spinal surgeries that were performed for chronic underlying neurologic and neuromuscular conditions, such as scoliosis, myelopathy, and spinal stenosis. We analyzed multiple montages at the baseline, and then followed their development throughout the procedure. Our intention was to examine the stability of the SEP recordings throughout the surgical procedure on multiple montages of cortical SEP recordings, with the goal of identifying the appropriate combination of the least number of montages that gives the highest yield of monitorable surgeries. Our study shows that it is necessary to have multiple montages for SEP recordings, as it reduces the number of non-monitorable cases, improves IOM reliability, and therefore could reduce false positives warnings to the surgeons. Out of all the typical montages available for use, our study has shown that the recording montage Cz-C4/Cz-C3 (Cz-Cc) is the most reliable and stable throughout the procedure and should be the preferred montage followed throughout the surgery.

  19. Flood scour monitoring system using fiber Bragg grating sensors

    Science.gov (United States)

    Lin, Yung Bin; Lai, Jihn Sung; Chang, Kuo Chun; Li, Lu Sheng

    2006-12-01

    The exposure and subsequent undermining of pier/abutment foundations through the scouring action of a flood can result in the structural failure of a bridge. Bridge scour is one of the leading causes of bridge failure. Bridges subject to periods of flood/high flow require monitoring during those times in order to protect the traveling public. In this study, an innovative scour monitoring system using button-like fiber Bragg grating (FBG) sensors was developed and applied successfully in the field during the Aere typhoon period in 2004. The in situ FBG scour monitoring system has been demonstrated to be robust and reliable for real-time scour-depth measurements, and to be valid for indicating depositional depth at the Dadu Bridge. The field results show that this system can function well and survive a typhoon flood.

  20. Network monitoring in the Tier2 site in Prague

    International Nuclear Information System (INIS)

    Eliáš, Marek; Fiala, Lukáš; Horký, Jirí; Chudoba, Jirí; Kouba, Tomáš; Kundrát, Jan; Švec, Jan

    2011-01-01

    Network monitoring provides different types of view on the network traffic. It's output enables computing centre staff to make qualified decisions about changes in the organization of computing centre network and to spot possible problems. In this paper we present network monitoring framework used at Tier-2 in Prague in Institute of Physics (FZU). The framework consists of standard software and custom tools. We discuss our system for hardware failures detection using syslog logging and Nagios active checks, bandwidth monitoring of physical links and analysis of NetFlow exports from Cisco routers. We present tool for automatic detection of network layout based on SNMP. This tool also records topology changes into SVN repository. Adapted weathermap4rrd is used to visualize recorded data to get fast overview showing current bandwidth usage of links in network.

  1. Monitoring in traumatic brain injury.

    Science.gov (United States)

    Matz, P G; Pitts, L

    1997-01-01

    In the past several years, improvements in technology have advanced the monitoring capabilities for patients with TBI. The primary goal of monitoring the patient with TBI is to prevent secondary insults to the brain, primarily cerebral ischemia. Cerebral ischemia may occur early and without clinical correlation and portends a poor outcome. Measurement of ICP is the cornerstone of monitoring in the patient with TBI. Monitoring of ICP provides a measurement of CPP and a rough estimation of CBF. However, with alterations in pressure autoregulation, measurement of CPP does not always allow for determination of CBF. To circumvent this problem, direct measurements of CBF can be performed using clearance techniques (133Xe, N2O, Xe-CT) or invasive monitoring techniques (LDF, TDF, NIRS). Although direct and quantitative, clearance techniques do not allow for continuous monitoring. Invasive CBF monitoring techniques are new, and artifactual results can be problematic. The techniques of jugular venous saturation monitoring and TCD are well established and are powerful adjuncts to ICP monitoring. They allow the clinician to monitor cerebral oxygen extraction and blood flow velocity, respectively, for any given CPP. Use of TCD may predict posttraumatic vasospasm before clinical sequelae. Jugular venous saturation monitoring may detect clinically occult episodes of cerebral ischemia and increased oxygen extraction. Jugular venous saturation monitoring optimizes the use of hyperventilation in the treatment of intracranial hypertension. Although PET and SPECT scanning allow direct measurement of CMRO2, these techniques have limited application currently. Similarly, microdialysis is in its infancy but has demonstrated great promise for metabolic monitoring. EEG and SEP are excellent adjuncts to the monitoring arsenal and provide immediate information on current brain function. With improvements in electronic telemetry, functional monitoring by EEG or SEP may become an important

  2. Acoustic Emission for on-line reactor pressure boundary monitoring

    International Nuclear Information System (INIS)

    Hutton, P.H.; Kurtz, R.J.; Pappas, R.A.

    1985-01-01

    The program objective is to develop AE for continuous surveillance to assess flaw growth in reactor pressure boundaries. Technology in the laboratory is being evaluated on structures. Results have demonstrated basic feasibility of the program objective. AE monitoring a long term fatigue test of a pressure vessel demonstrated an instrument system, and the ability to detect unexpected as well as well as known fatigue cracks. Monitoring a nuclear reactor system shows that the coolant flow noise problem is manageable and AE can be detected under simulated operating conditions

  3. Technology of remote monitoring for nuclear activity monitoring

    International Nuclear Information System (INIS)

    Kwack, Ehn Ho; Kim, Jong Soo; Yoon, Wan Ki; Park, Sung Sik; Na, Won Woo; An, Jin Soo; Cha, Hong Ryul; Kim, Jung Soo

    2000-05-01

    In a view of safeguards monitoring at nuclear facilities, the monitoring is changing to remote method so that this report is described to remote monitoring(RM) applying on commercial NPP in Korea. To enhance IAEA safeguards efficiency and effectiveness, IAEA is taking into account of remote monitoring system(RMS) and testing as a field trial. IRMP(International Remote Monitoring Project) in participating many nations for development of RMS is proceeding their project such as technical exchange and research etc. In case of our country are carrying out the research relevant RM since acceptance RMS at 7th ROK-IAEA safeguards implementation review meeting. With a view to enhancement the RMS, installation location and element technology of the RM equipment are evaluated in a view of safeguards in Korea LWRs, and proposed a procedure for national inspection application through remote data evaluation from Younggwang-3 NPP. These results are large valuable to use of national inspection at time point extending installation to all Korea PWR NPP. In case of CANDU, neutron, gamma measurement and basic concept of network using optical fiber scintillating detector as remote verification method for dry storage canister are described. Also RM basic design of spent fuel transfer campaign is described that unattended RM without inspector instead of performing in participating together with IAEA and national inspector. The transfer campaign means the spent fuel storage pond to dry storage canister for about two months every year. Therefore, positively participation of IAEA strength safeguards project will be increased transparency for our nuclear activity as well as contributed to national relevant industry

  4. Technology of remote monitoring for nuclear activity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kwack, Ehn Ho; Kim, Jong Soo; Yoon, Wan Ki; Park, Sung Sik; Na, Won Woo; An, Jin Soo; Cha, Hong Ryul; Kim, Jung Soo

    2000-05-01

    In a view of safeguards monitoring at nuclear facilities, the monitoring is changing to remote method so that this report is described to remote monitoring(RM) applying on commercial NPP in Korea. To enhance IAEA safeguards efficiency and effectiveness, IAEA is taking into account of remote monitoring system(RMS) and testing as a field trial. IRMP(International Remote Monitoring Project) in participating many nations for development of RMS is proceeding their project such as technical exchange and research etc. In case of our country are carrying out the research relevant RM since acceptance RMS at 7th ROK-IAEA safeguards implementation review meeting. With a view to enhancement the RMS, installation location and element technology of the RM equipment are evaluated in a view of safeguards in Korea LWRs, and proposed a procedure for national inspection application through remote data evaluation from Younggwang-3 NPP. These results are large valuable to use of national inspection at time point extending installation to all Korea PWR NPP. In case of CANDU, neutron, gamma measurement and basic concept of network using optical fiber scintillating detector as remote verification method for dry storage canister are described. Also RM basic design of spent fuel transfer campaign is described that unattended RM without inspector instead of performing in participating together with IAEA and national inspector. The transfer campaign means the spent fuel storage pond to dry storage canister for about two months every year. Therefore, positively participation of IAEA strength safeguards project will be increased transparency for our nuclear activity as well as contributed to national relevant industry.

  5. Fluid-flow monitoring using electromagnetic probing

    International Nuclear Information System (INIS)

    Lytle, R.J.; Lager, D.L.; Laine, E.F.; Salisbury, J.D.; Okada, J.T.

    1979-01-01

    High-frequency electromagnetic probing is used to monitor the rate and direction of flow of fluids injected into the ground. This method shows the potential for providing more detailed information than procedures presently used. The experimental technique and the test-of-concept experimental results are discussed. This technique has applications in oil-reservoir engineering and in hydrology studies concerning storage of chemical and nuclear wastes. 11 figures

  6. A novel calorimetry technique for monitoring electron beam curing of polymer resins

    International Nuclear Information System (INIS)

    Chen, J.H.; Johnston, A.; Petrescue, L.; Hojjati, M.

    2006-01-01

    This paper describes the development of a calorimetry-based technique for monitoring of the curing of electron beam (EB) curable resins, including design of the calorimeter hardware and the development of an analytical model for calculating resin cure rates and radiation dose. Factors affecting the performance of the calorimeter were investigated. Experimental trials monitoring the curing of epoxy resin were conducted under single pass and multiple passes of EB irradiation. Results show that the developed calorimeter is a simple, inexpensive and reasonably accurate technique for monitoring the EB curing of cationic epoxies

  7. Nuclear reactor effluent monitoring

    International Nuclear Information System (INIS)

    Minns, J.L.; Essig, T.H.

    1993-01-01

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC's program results

  8. Nuclear reactor effluent monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Minns, J.L.; Essig, T.H. [Nuclear Regulatory Commission, Washington, DC (United States)

    1993-12-31

    Radiological environmental monitoring and effluent monitoring at nuclear power plants is important both for normal operations, as well as in the event of an accident. During normal operations, environmental monitoring verifies the effectiveness of in-plant measures for controlling the release of radioactive materials in the plant. Following an accident, it would be an additional mechanism for estimating doses to members of the general public. This paper identifies the U.S. Nuclear Regulatory Commission (NRC) regulatory basis for requiring radiological environmental and effluent monitoring, licensee conditions for effluent and environmental monitoring, NRC independent oversight activities, and NRC`s program results.

  9. Functional food monitoring as part of the new Dutch dietary monitoring system

    NARCIS (Netherlands)

    Rompelberg CJM; Jager M; Bakker MI; Buurma-Rethans EJM; Ocke MC; CVG

    2006-01-01

    Good data on functional food consumption necessary for an adequate Dutch nutrition policy are lacking. This lack may be overcome in future by including functional food monitoring in the new dietary monitoring system in the Netherlands. One specific form of monitoring could be an Internet-based

  10. Design of Heavy Metals Monitoring System in Water Based on WSN and GPRS

    Directory of Open Access Journals (Sweden)

    Ke Lin

    2014-04-01

    Full Text Available In order to realize the real-time monitoring of heavy metals in water environment, a new type of heavy metal monitoring system was developed. The system was composed of monitoring terminal, gateway, GPRS network and upper computer monitoring center. The system detected the heavy metal ion concentrations by ion-selective electrode array and came into the system error automatic compensation method in the detection process. The collecting data was transported to the monitoring center through the cooperation between the wireless sensor network constituted by CC2530 and General Packet Radio Service network. The test result shows that the system can increased precision dramatically and strengthens the real-time transmission capacity effectively. The system is reliable in transmission, high real-time performance, flexible in networking and can be applied to continuous remote monitoring of heavy metals pollution.

  11. Highland Medical Research Journal - Vol 15, No 2 (2015)

    African Journals Online (AJOL)

    Descriptive evaluation of holter recordings at a teaching hospital in central Nigeria · EMAIL FULL TEXT EMAIL FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Caleb M. Chundusu, Maxwel O. Akanbi, James A. Onuh, Ganiyu A. Amusa, Solomon S. Danbauchi, Basil N. Okeahialam, 59-62 ...

  12. Evaluation Of Vibration-Monitoring Gear-Diagnostic System

    Science.gov (United States)

    Townsend, Dennis P.; Zakrajsek, James J.

    1995-01-01

    Report describes experimental evaluation of commercial electronic system designed to monitor vibration signal from accelerometer on gear-box to detect vibrations indicative of damage to gears. System includes signal-conditioning subsystem and personal computer in which analog-to-digital converter installed. Results show system fairly effective in detecting surface fatigue pits on spur-gear teeth.

  13. In vitro anticoagulation monitoring of low-molecular-weight heparin

    Institute of Scientific and Technical Information of China (English)

    WANG Jian-qi; SHI Xu-bo; YANG Jin-gang; HU Da-yi

    2009-01-01

    Background Although low-molecular-weight heparin has replaced unfractionated heparin to become the primary anticoagulation drug for treatment of acute coronary syndrome, there is no convenient bedside monitoring method. We explored the best laboratory monitoring method of low-molecular-weight heparins (enoxapadn, dalteparin, and nadroparin) by use of the Sonoclot coagulation analyzer to monitor the activated clotting time.Methods Atotal of 20 healthy volunteers were selected and 15 ml of fasting venous blood samples were collected and incubated. Four coagulants, kaolin, diatomite, glass bead, and magnetic stick, were used to determine the activated clotting time of the low-molecular-weight heparins at different in vitro anti-Xa factor concentrations. A correlation analysis was made to obtain the regression equation. The activated clotting time of the different low-molecular-weight heparins with the same anti-Xa factor concentration was monitored when the coagulant glass beads were applied. Results The activated clotting time measured using the glass beads, diatomite, kaolin, and magnetic stick showed a linear correlation with the concentration of nadroparin (r= 0.964, 0.966, 0.970, and 0.947, respectively). The regression equation showed that the linear slopes of different coagulants were significantly different (glass beads 230.03 s/IU,diatomite 89.91 s/IU, kaolin 50.87 s/IU, magnetic stick could not be calculated). When the concentration of the anti-Xa factor was the same for different low-molecular-weight heparins, the measured activated clotting time was different after the application of the glass bead coagulant.Conclusions The glass bead coagulant is most feasible for monitoring the in vitro anticoagulation activity of nadroparin.The different effects of different low-molecular-weight heparins on the activated clotting time may be related to the different anti-Ila activities.

  14. Development and seismic evaluation of the seismic monitoring analysis system for HANARO

    International Nuclear Information System (INIS)

    Ryu, J. S.; Youn, D. B.; Kim, H. G.; Woo, J. S.

    2003-01-01

    Since the start of operation, the seismic monitoring system has been utilized for monitoring an earthquake at the HANARO site. The existing seismic monitoring system consists of field sensors and monitoring panel. The analog-type monitoring system with magnetic tape recorder is out-of-date model. In addition, the disadvantage of the existing system is that it does not include signal-analyzing equipment. Therefore, we have improved the analog seismic monitoring system except the field sensors into a new digital Seismic Monitoring Analysis System(SMAS) that can monitor and analyze earthquake signals. To achieve this objective for HANARO, the digital type hardware of the SMAS has been developed. The seismic monitoring and analysis programs that can provide rapid and precise information for an earthquake were developed. After the installation of the SMAS, we carried out the Site Acceptance Test (SAT) to confirm the functional capability of the newly developed system. The results of the SAT satisfy the requirements of the fabrication technical specifications. In addition, the seismic characteristics and structural integrity of the SMAS were evaluated. The results show that the cabinet of SMAS can withstand the effects of seismic loads and remain functional. This new SMAS is operating in the HANARO instrument room to acquire and analyze the signal of an earthquake

  15. Space weather monitoring by groundbased means

    CERN Document Server

    Troshichev, Oleg

    2012-01-01

    This book demonstrates that the method, based on the ground polar cap magnetic observations is a reliable diagnosis of the solar wind energy coming into the magnetosphere Method for the uninterruptive monitoring of the magnetosphere state (i.e. space weather). It shows that the solar wind energy pumping power, can be described by the PC growth rate, thus, the magnetospheric substorms features are predetermined by the PC dynamics. Furthermore, it goes on to show that the beginning and ending of magnetic storms is predictable. The magnetic storm start only if the solar energy input into the magn

  16. Monitoring during the stepwise implementation of the Swedish deep repository for spent fuel

    Energy Technology Data Exchange (ETDEWEB)

    Baeckblom, Goeran [Conrox (Sweden); Almen, Karl-Erik [KEA Geokonsult AB (Sweden)

    2004-03-01

    Monitoring in this report is defined as 'Continuous or repeated observations or measurements of parameters to increase the scientific understanding of the site and the repository, to show compliance with requirements or for adaptation of plans in light of the monitoring results.' The international outlook from IAEA, OECD/NEA, CEC and some country-specific reviews presented in the report forms a necessary background to the Swedish monitoring framework. The implementation of the deep repository in Sweden is executed in phases where monitoring is an inherently integrated activity in the programme. The first phase is the site investigations when Primary Baseline conditions are established. During the following construction phase of the repository, detailed site characterisation continues in conjunction with construction of the access to the deposition area, construction of parts of the deposition area and the central service area. Monitoring is then used to track the changes to the previously established Primary Baseline conditions and distinguishing these imposed changes from natural variations or from other man-made influences. During the initial operation phase, around 200-400 canisters of spent fuel is emplaced and deposition tunnels backfilled. After up-dated evaluations, the phase of regular operation begin, where detailed characterisation, construction of the repository and waste emplacement are concurrent activities. The closure of the repository will take place when all spent fuel has been emplaced, i.e. in the latter part of this century. Monitoring during the stepwise implementation of the repository is executed of several reasons mainly to: describe the Primary Baseline conditions of the repository site, develop and demonstrate understanding of the repository site and the behaviour of engineered barriers, assist in the decision-making process, show compliance with international and national guidelines and regulations. Specific rationales for

  17. The impact of clinical trial monitoring approaches on data integrity and cost--a review of current literature.

    Science.gov (United States)

    Olsen, Rasmus; Bihlet, Asger Reinstrup; Kalakou, Faidra; Andersen, Jeppe Ragnar

    2016-04-01

    Monitoring is a costly requirement when conducting clinical trials. New regulatory guidance encourages the industry to consider alternative monitoring methods to the traditional 100 % source data verification (SDV) approach. The purpose of this literature review is to provide an overview of publications on different monitoring methods and their impact on subject safety data, data integrity, and monitoring cost. The literature search was performed by keyword searches in MEDLINE and hand search of key journals. All publications were reviewed for details on how a monitoring approach impacted subject safety data, data integrity, or monitoring costs. Twenty-two publications were identified. Three publications showed that SDV has some value for detection of not initially reported adverse events and centralized statistical monitoring (CSM) captures atypical trends. Fourteen publications showed little objective evidence of improved data integrity with traditional monitoring such as 100 % SDV and sponsor queries as compared to reduced SDV, CSM, and remote monitoring. Eight publications proposed a potential for significant cost reductions of monitoring by reducing SDV without compromising the validity of the trial results. One hundred percent SDV is not a rational method of ensuring data integrity and subject safety based on the high cost, and this literature review indicates that reduced SDV is a viable monitoring method. Alternative methods of monitoring such as centralized monitoring utilizing statistical tests are promising alternatives but have limitations as stand-alone tools. Reduced SDV combined with a centralized, risk-based approach may be the ideal solution to reduce monitoring costs while improving essential data quality.

  18. Bedload-surrogate monitoring technologies

    Science.gov (United States)

    Gray, John R.; Laronne, Jonathan B.; Marr, Jeffrey D.G.

    2010-01-01

    Advances in technologies for quantifying bedload fluxes and in some cases bedload size distributions in rivers show promise toward supplanting traditional physical samplers and sampling methods predicated on the collection and analysis of physical bedload samples. Four workshops held from 2002 to 2007 directly or peripherally addressed bedload-surrogate technologies, and results from these workshops have been compiled to evaluate the state-of-the-art in bedload monitoring. Papers from the 2007 workshop are published for the first time with this report. Selected research and publications since the 2007 workshop also are presented. Traditional samplers used for some or all of the last eight decades include box or basket samplers, pan or tray samplers, pressure-difference samplers, and trough or pit samplers. Although still useful, the future niche of these devices may be as a means for calibrating bedload-surrogate technologies operating with active- and passive-type sensors, in many cases continuously and automatically at a river site. Active sensors include acoustic Doppler current profilers (ADCPs), sonar, radar, and smart sensors. Passive sensors include geophones (pipes or plates) in direct contact with the streambed, hydrophones deployed in the water column, impact columns, and magnetic detection. The ADCP for sand and geophones for gravel are currently the most developed techniques, several of which have been calibrated under both laboratory and field conditions. Although none of the bedload-surrogate technologies described herein are broadly accepted for use in large-scale monitoring programs, several are under evaluation. The benefits of verifying and operationally deploying selected bedload-surrogate monitoring technologies could be considerable, providing for more frequent and consistent, less expensive, and arguably more accurate bedload data obtained with reduced personal risk for use in managing the world's sedimentary resources. Twenty-six papers are

  19. An automatic monitoring system of leak current for testing TGC detectors based on LabVIEW

    International Nuclear Information System (INIS)

    Feng Cunfeng; Lu Taiguo; Yan Zhen; Wang Suojie; Zhu Chengguang; Sun Yansheng; He Mao

    2005-01-01

    An automatic monitoring system of leak current for testing TGC detectors with high voltage was set up by using the graphic LabVIEW platform and NI 4351 data acquisition card. The leak current was automatically monitored and recorded with this system, the time and the value of the leak current were showed instantly. Good efficiency and precision of monitoring were obtained. (authors)

  20. Building of effluence and environment monitoring capability of uranium mining and metallurgy in China

    International Nuclear Information System (INIS)

    Li Xianjie; Hu Penghua; Duan Jianchen; Xue Jianxin

    2014-01-01

    The status of effluence and environmental monitoring capability of nine uranium mining and metallurgy corporations in operation in China was investigated and analyzed. The results show that there exist some problems in all corporations such as imperfect monitoring plan, ineligible analyst, aging equipment, insufficient analysis capacity, lack of good detection limit. In order to solve the problems, several steps have been taken by Department of Safety and Environment Protection and Department of Geology and Mining (CNNC) in three years, including establishing three-level monitoring sys- tem, equipping corresponding monitoring instrument, holding three training classes, enhancing the analyst capacity, publishing the model for effluence and environment monitoring capability of uranium mining and metallurgy and carrying out comparison on monitoring of U and Ra in water, which greatly improved effluence and environment monitoring capability of uranium mining and metallurgy. (authors)