Sample records for holmium-166 irradiator device

  1. Ocular brachytherapy with a holmium-166 irradiator device

    International Nuclear Information System (INIS)

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2009-01-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  2. Ocular brachytherapy with a holmium-166 irradiator device

    Energy Technology Data Exchange (ETDEWEB)

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnoloica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares], e-mail: campos@nuclear.ufmg.br

    2009-07-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  3. Effects of Intraluminal Irradiation with Holmium-166 for TIPS Stenosis: Experimental Study in a Swine Model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Seon; Oh, Joo Hyeong; Kim, Deog Yoon; Park, Yong Koo; Kim, Soo Joong [Kyung Hee University Medical Center, Seoul (Korea, Republic of); Park, Sang Joon [Kang Dong Sacred Heart Hospital, Hallym University, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to evaluate the effectiveness of intraluminal irradiation with Holmium-166 ({sup 166}Ho) for reducing the pseudointimal hyperplasia (PIH) in the transjugular intrahepatic portosystemic shunt (TIPS) tract in a swine model. TIPS was performed in 12 domestic pigs, after the creation of portal hypertension by intraportal injection of a mixture of N-butyl-2- cyanoacrylate (NBCA) and lipiodol. Five pigs first underwent intraluminal irradiation (30 Gy) in the parenchymal tract with using a {sup 166}Ho solution-filled balloon catheter, and this was followed by the placement of a nitinol stent in the TIPS tract. For the seven control pigs, the balloon was filled with saline and contrast media mixture. Two weeks later, follow-up portography and histological analysis were performed. TIPS was successfully performed in all twelve pigs with achieving artificially induced portal hypertension. Portography performed two weeks after TIPS showed the patent tracts in the TIPS tracts that were irradiated with {sup 166}Ho (5/5, 100%), whereas either completely (5/6, 83.3%) or partially (1/6, 16.7%) occluded TIPS were seen in the seven pigs of the nonirradiated control group, except in one pig that experienced periprocedural death due to bleeding. Histological analysis showed a statistically significant difference for the maximal PIH (irradiated: 32.8%, nonirradiated: 76.0%, p < 0.001) between the two groups. Intraluminal irradiation with 30 Gy of {sup 166}Ho for TIPS significantly improved the TIPS patency in a swine model of portal hypertension during a 2- week period of follow-up.

  4. Calcium phosphate holmium-166 ceramic to addition in bone cement: synthesis and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Donanzam, Blanda A.; Campos, Tarcisio P.R., E-mail: campos@nuclear.ufmg.b [Universidade do Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Nuclear; Dalmazio, Ilza; Valente, Eduardo S., E-mail: id@cdtn.b, E-mail: valente@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Spine metastases are a common and painful complication of cancer. The treatment often consists of bone cement injection (vertebroplasty or kyphoplasty) within vertebral body for vertebrae stabilization, followed by external beam radiation therapy. Recently, researchers introduced the concept of radioactive bone cement for spine tumors therapy. Then, investigations about bioactive and radioactive materials became interesting. In this study, we present the synthesis of calcium phosphate incorporated holmium (CaP-Ho) via sol-gel technique, and its characterization by XRD, FT-IR, NA and SEM. Results showed a multiphasic bioceramic composed mainly of hydroxyapatite, {beta}-tricalcium phosphate, holmium phosphate and traces of calcium pyrophosphate. Furthermore, the nuclide Ho-166 was the major radioisotope produced. Despite that, the radioactive bioceramic CaP-{sup 166}Ho must be investigated in clinical trials to assure its efficacy and safety on spine tumors treatment (author)

  5. Calcium phosphate holmium-166 ceramic to addition in bone cement: synthesis and characterization

    International Nuclear Information System (INIS)

    Donanzam, Blanda A.; Campos, Tarcisio P.R.

    2011-01-01

    Spine metastases are a common and painful complication of cancer. The treatment often consists of bone cement injection (vertebroplasty or kyphoplasty) within vertebral body for vertebrae stabilization, followed by external beam radiation therapy. Recently, researchers introduced the concept of radioactive bone cement for spine tumors therapy. Then, investigations about bioactive and radioactive materials became interesting. In this study, we present the synthesis of calcium phosphate incorporated holmium (CaP-Ho) via sol-gel technique, and its characterization by XRD, FT-IR, NA and SEM. Results showed a multiphasic bioceramic composed mainly of hydroxyapatite, β-tricalcium phosphate, holmium phosphate and traces of calcium pyrophosphate. Furthermore, the nuclide Ho-166 was the major radioisotope produced. Despite that, the radioactive bioceramic CaP- 166 Ho must be investigated in clinical trials to assure its efficacy and safety on spine tumors treatment (author)

  6. Clinical effects of transcatheter hepatic arterial embolization with holmium-166 poly(l-lactic acid) microspheres in healthy pigs

    Energy Technology Data Exchange (ETDEWEB)

    Vente, M.A.D.; Nijsen, J.F.W.; Wit, T.C. de; Schip, A.D. van het [University Medical Center Utrecht, Department of Nuclear Medicine, P.O. Box 85500, Utrecht (Netherlands); Seppenwoolde, J.H.; Seevinck, P.R. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Krijger, G.C. [Delft University of Technology, Department of Radiation, Radionuclides and Reactors, Faculty of Applied Sciences, Delft (Netherlands); Huisman, A. [University Medical Center Utrecht, Department of Clinical Chemistry and Haematology, Utrecht (Netherlands); Zonnenberg, B.A. [University Medical Center Utrecht, Department of Internal Medicine, Utrecht (Netherlands); Ingh, T.S.G.A.M. van den [TCCI Consultancy B.V., P.O. Box 85032, Utrecht (Netherlands)

    2008-07-15

    The aim of this study is to evaluate the toxicity of holmium-166 poly(l-lactic acid) microspheres administered into the hepatic artery in pigs. Healthy pigs (20-30 kg) were injected into the hepatic artery with holmium-165-loaded microspheres ({sup 165}HoMS; n = 5) or with holmium-166-loaded microspheres ({sup 166}HoMS; n = 13). The microspheres' biodistribution was assessed by single-photon emission computed tomography and/or MRI. The animals were monitored clinically, biochemically, and ({sup 166}HoMS group only) hematologically over a period of 1 month ({sup 165}HoMS group) or over 1 or 2 months ({sup 166}HoMS group). Finally, a pathological examination was undertaken. After microsphere administration, some animals exhibited a slightly diminished level of consciousness and a dip in appetite, both of which were transient. Four lethal adverse events occurred in the {sup 166}HoMS group due either to incorrect administration or comorbidity: inadvertent delivery of microspheres into the gastric wall (n = 2), preexisting gastric ulceration (n = 1), and endocarditis (n = 1). AST levels were transitorily elevated post-{sup 166}HoMS administration. In the other blood parameters, no abnormalities were observed. Nuclear scans were acquired from all animals from the {sup 166}HoMS group, and MRI scans were performed if available. In pigs from the {sup 166}HoMS group, atrophy of one or more liver lobes was frequently observed. The actual radioactivity distribution was assessed through ex vivo {sup 166m}Ho measurements. It can be concluded that the toxicity profile of HoMS is low. In pigs, hepatic arterial embolization with {sup 166}HoMS in amounts corresponding with liver-absorbed doses of over 100 Gy, if correctly administered, is not associated with clinically relevant side effects. This result offers a good perspective for upcoming patient trials. (orig.)

  7. Evaluation of samarium-153 and holmium-166-EDTMP in the normal baboon model

    Energy Technology Data Exchange (ETDEWEB)

    Louw, W.K.A.; Dormehl, I.C.; Rensburg, A.J. van; Hugo, N.; Alberts, A.S.; Forsyth, O.E.; Beverley, G.; Sweetlove, M.A.; Marais, J.; Loetter, M.G.; Aswegen, A. van

    1996-11-01

    Bone-seeking radiopharmaceuticals such as ethylenediaminetetramethylene phosphonate (EDTMP) complexes of samarium-153 and holmium-166 are receiving considerable attention for therapeutic treatment of bone metastases. In this study, using the baboon experimental model, multicompartmental analysis revealed that with regard to pharmacokinetics, biodistribution, and skeletal localisation, {sup 166}Ho-EDTMP was significantly inferior to {sup 153}Sm-EDTMP and {sup 99m}Tc-MDP. A more suitable {sup 166}Ho-bone-seeking agent should thus be sought for closer similarity to {sup 153}Sm-EDTMP to exploit fully the therapeutic potential of its shorter half-life and more energetic beta radiation.

  8. Safety analysis of holmium-166 microsphere scout dose imaging during radioembolisation work-up. A cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Braat, Arthur J.A.T.; Prince, Jip F.; Rooij, Rob van; Bruijnen, Rutger C.G.; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands)

    2018-03-15

    Radioembolisation is generally preceded by a scout dose of technetium-99m-macroaggregated albumin to estimate extrahepatic shunting of activity. Holmium-166 microspheres can be used as a scout dose (±250 MBq) and as a therapeutic dose. The general toxicity of a holmium-166 scout dose ({sup 166}Ho-SD) and safety concerns of an accidental extrahepatic deposition of {sup 166}Ho-SD were investigated. All patients who received a {sup 166}Ho-SD in our institute were reviewed for general toxicity and extrahepatic depositions. The absorbed dose in extrahepatic tissue was calculated on SPECT/CT and correlated to clinical toxicities. In total, 82 patients were included. No relevant clinical toxicity occurred. Six patients had an extrahepatic deposition of {sup 166}Ho-SD (median administered activity 270 MBq). The extrahepatic depositions (median activity 3.7 MBq) were located in the duodenum (3x), gastric fundus, falciform ligament and the lesser curvature of the stomach, and were deposited in a median volume of 15.3 ml, which resulted in an estimated median absorbed dose of 3.6 Gy (range 0.3-13.8 Gy). No adverse events related to the extrahepatic deposition of the {sup 166}Ho-SD occurred after a median follow-up of 4 months (range 1-12 months). These results support the safety of 250 MBq {sup 166}Ho-SD in a clinical setting. (orig.)

  9. Study of intraarticular application of 166-Holmium IHPP in healthy hares

    International Nuclear Information System (INIS)

    Szentesi, M.; Koernyei, J.; Antalffi, M.; Toerkoe, J.; Toth, G.Y.; Janoki, G.Y.; Balogh, L.

    2002-01-01

    Radiosynoviorthesis non invasive therapy in rheumatoid arthritis is an alternative of surgical synovectomy. This method was applied first by Fellinger in 1952, and since then it has been practiced all over the world. The leakage of traditionally applied isotopes is cca. 4-10%, and the whole body dose is 10 rads. The objective of our work is to produce a nuclear medication with a minimum radioactive load, of short half-life and ideal molecule size for the treatment of radiosynoviorthesis / 166- Holmium IHPP / and the study of its effect on healthy hares. The first results have been already reported on previously. 166-Holmium IHPP has the features of: half-life of 26.9 hr, the maximum soft-tissue penetration of a beta particle 1.84 MeV, emitted from 166-Ho 8.4 mm. With an average of 3.3 mm. Methods applied: Biodistribution analysis, gamma camera analysis, biochemical and histological tests with photo- and electro microscope were carried out on healthy New Zealand hares 6, 24, 72, 168 hours after radiosynoviorthesis. Results: All the testing methods applied showed that 97 /96,1-98,2/ % remained on the spot of the injection and the 2/3 of the small percentage released leakage: is excreted by the liver and the other 1/3 of it with the urine.The hematological and biochemical parameters did not show differences. During histological examination moderate level acute radioarthritis in the knee joint treated was observed (6-24 hours after the injection), then moderate level subacute radioarthritis with slight degeneration in the synovial membrane and in the synovial fluid. It was only the electro microscopic examination that did show a minimal degeneration in the cartilage and in the menisci, but it got regenerated in 168 hours. Conclusion: The examination carried out has proved that 166-Ho -IHPP can be effectively applied in radiosynoviorthesis. Clinical testing has started

  10. Holmium-166-chico intracavitary radiation therapy for cystic brain tumors

    Energy Technology Data Exchange (ETDEWEB)

    Rhee, C. H.; Lee, S. H.; Jang, J. S.; Kim, E. H.; Choi, C. W.; Hong, S. W.; Lim, S. M. [Korea Cancer Center, Seoul (Korea, Republic of)

    1997-07-01

    Holmium-166-chitosan complex (Ho-166-chico) is injected into the unresectable seven cystic brain tumors (2 cases of metastatic brain tumors from lung cancer, 1 case of recurrent trigeminal neurinoma, 3 cases of recurrent low grade cystic astrocytomas, and 1 case of craniopharyngioma). The Ommaya reservoir was installed stereotactically. The cyst volume and wall thickness were measured by MRI before Ho-166-chico injection. The thickness of the cyst wall is up to 4 mm. Ho-166-chico (555-740 MBq) injected into the cyst to result in 25 Gy of dose to a cyst wall at a depth of 4 mm. Dose to the cyst wall was estimated by Monte Carlo simulation using the EGS4 code. All Ho-166-chico injected was assumed to be uniformly distributed in the spherical cyst. After Ho-166-chico injection, the distribution of isotopes was monitored by gamma camera. Two injections were administrated in two cases, and one injection in all the others. The response was evaluated with MRI. Four of 7 cases were shrunk in size with thinning of the cyst wall, 2 of 7 cases showed growth arrest, and one case showed progression. Estimated surface dose of cyst wall was between 78 and 2566 Gy. No one showed systemic absorption of Ho-166-chico, and specific complication associated with isotope injection. Ho-166-chico intracavitary radiation therapy for cystic brain tumor may be safe, and reliable method and deserves further evaluation.

  11. Radiopharmaceuticals of DTPA, DMSA and EDTA labeled with holmium-166

    International Nuclear Information System (INIS)

    Rahman, M.; Matsouka, H.; Takami, S.; Terunuma, K.

    2001-01-01

    DTPA, DMSA and EDTA were labelled with 166 Ho of low specific activity, 250-275mCi/mg of Ho, produced from holmium oxide by the 165 Ho(n, g) 166 Ho reaction at a neutron flux of about 10 14 n.cm -2 .s -1 . Three pH ranges were selected in the study, viz. 2-3, 3-3.5 and 5-6. The labelling reactions were studied as chloride and nitrate solutions in aqueous and saline media at 30 min and 20-24 h of reaction. DTPA was labelled over 99, DMSA at about 90 and EDTA at 100.0% with 166 Ho. The complexes were found stable at all times of investigation. A beta chromatogram scanner was used to study by TLC the labelling reactions of DTPA and DMSA with the nuclide and by PC those of EDTA. A biodistribution study in three rats injected intravenous with a saline solution of 166 HoCl 3 [DTPA] at pH5.1 showed an initial uptake in blood, kidney and lung after 30 minutes. After four hours the complex was found to have cleared from blood and lung, and localized 100% in kidney. It was stable in vivo in the kidney after 24 hours. The g spectrum analysis did not show the formation of any impurity except the four characteristic g energies of 166 Ho. (author)

  12. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  13. Gamma spectrometry and chemical characterization of bioactive glass seeds with Holmium-166 for oncological implants

    International Nuclear Information System (INIS)

    Valente, Eduardo S.

    2009-01-01

    Bioactive glass seeds synthesized by the sol-gel technique with Si:Ho:Ca composition with natural holmium incorporated were irradiated in the TRIGA type nuclear reactor IPR-R1 at 100kW, in the central thimble where the thermal neutron flux is 2.8x10 12 n/cm 2 .s and the epithermal neutron flux is 2.6 X 10 11 n/cm 2 .s . After an 8 hour irradiation time, with an induced activity close to 110MBq/seed, a set of seeds was submitted to Gamma Spectrometry Analysis in a counting system with an HPGe detector, ORTEC electronic instrumentation and a Camberra Multichannel Analyser, to determine all radionuclides present on the sample as well as its individual activities. Special attention was paid on the discrimination of Si, 40 Ca, 44 Ca, C and Ho as the other expected elements like 48 Ca, 2 H and 18 O were present in traces or have very short half-lives. The second sample was submitted to Plasma spectrometry to determine the 166 Ho concentration in weight. The third sample was submitted to an X-ray spectrometry in a JEOL-JXA-8900RL equipment to determine its qualitative chemical composition, in order to evaluate impurities and nominal composition. It was determined that most of the activity, after decaying of short half-life elements, was due to 166 Ho present on the sample, with a well characterized β and gamma spectra. The homogeneity of the seeds was tested on the X-ray spectrometry, and verified that there is no discrepancy in composition from distinct seeds or in a same seed. The results are relevant on the investigation of the viability of producing 166 Ho radioactive seeds for oncological implants. (author)

  14. Our first clinical experience with radiosynoviorthesis by means of (166)Ho-holmium-boro-macroaggregates.

    Science.gov (United States)

    Kraft, Otakar; Kasparek, R; Ullmann, V; Melichar, F; Kropacek, M; Mirzajevov, M

    2005-01-01

    In this paper, we evaluate the therapeutic and adverse effects of the application of 166-holmium-boro-macroaggregates (HMBA) in radiosynovectomy (RSO) of the knees. We assessed the efficacy and safety of (166)Ho-HBMA in a prospective clinical trial in patients suffering from chronic synovitis. An effective component of radiopharmaceutical (166)Ho-boro-macroaggregates is radionuclide (166)Ho which has both beta-emission and gamma-emission. The physical half-life time of 166 Ho is 26.8 hours. After application of the radiopharmaceutical into a joint cavity, the effect of beta-emission causes radiation necrosis of pathologically changed (inflamed) synovial membrane. From 15th April 2005, we have started RSO of knees by means of new radiopharmaceutical (166)Ho-boro-macroaggregates in patients with gonarthrosis, rheumatoid arthritis, chronic synovitis, psoriatic arthritis, gout arthropathy. Seventeen intra-articular injections were performed in fifteen patients receiving a mean activity of 972 MBq (range: 904-1,057 MBq) (166)Ho-HMBA. The patients were hospitalized for three days. Side effects were evaluated during hospital stay and after 6-8 weeks. Static scintigraphy of knee joints and measurements of blood radioactivity were performed. Therapeutic effects were evaluated after 6-8 weeks. In 2 hours and 2 days after application, we proved, by means of knee and inguinal scintigraphy, only insignificant radiopharmaceutical leakage from the joint cavity to the inguinal lymph nodes in four patients. In treated patients, no serious adverse effects occurred. Nine patients were without complaints; 4 patients had slight knee exsudation and 2 patients had great exsudation. Therapeutic effects after 6-8 weeks were as follows: 2 patients were without pain, 9 with lower pain, 3 with the same pain and 1 patient with increased pain. Joint motion was improved in 7 patients, remained the same in 7 patients and was impaired in 1 patient. Analgesics consumption was lower in 5 patients

  15. Studies on therapeutic method of liver cancer(hapatocellular carcinome)by Holmium-166 radionuclide

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tae; Yoo, H. S.; Kim, M. J.; Han, K. H.; Park, C. I. [Yonsei University Medical College, Seoul (Korea, Republic of)

    1997-07-01

    As the study of radioactive nuclide, Holmium-166 in the treatment of liver cancer(hepatocellular carcinoma), this study was performed under the base of animal experimental. Using dog liver, percutaneous injection of Ho-166 MAA or chitosan with premade dose was done under the ultrasound guidance. Continuously the same procedure as previous one was performed in the skin hapatoma, which was developed by the injection of hepatocellular carcinoma cell in the nude mouse, In case of injected normal liver of dog, imaging study including ultrasound, CT and MRI was done in order to evaluate effect of Ho-166 and pathologic reaction. The result showed well defined nectosis of normal liver as well as skin hepatoma. The area of nectosis is dependent on the dose of injected Ho-166. Generally, pathologic reaction is tissue coagulation nectosis, Ho-166 particles, fibrosis and hemorrhage. In the clinical study, 50 patients with hapatoma was selected for this study under the agreement of patient. Under ultrasound guidance percutaneous injection of Ho-166 Maa or chitosan to tumor was performed and follow-up study was extended from 6 to 12 month. The result showed that 64% of patient were completely treated. Overall, the effect of treatment could be obtained in 41 patient (82%) among 50 hepatoma patient. Conclusively Ho-166 is thought to be a compromising agent in the treatment of hepatocellular carcinoma and one of therapeutic modality, if it is established internally and world-wide. In the future, the popular percutaneous ethanol injection method will be replaced to this method. 19 refs., 1 tabs., 14 figs. (author)

  16. Automated production of no carrier added holmium-166

    International Nuclear Information System (INIS)

    Izard, M.E.; Dadchova, E.

    1996-01-01

    Full text: An automated system has been developed to produce no carrier added 166 Ho from the decay of 166 Dy produced by neutron activation of 164 Dy 2 O 3 . Targets consisting of 5-10 mg of 164 Dy 2 O 3 are irradiated in HIFAR at 5 x 10 13 n.s -1 .cm -2 for 12h then allowed to cool for 2 days. The irradiation can is then transferred to the automated system located in a 'hot' cell in the radiopharmaceutical research building. A two dimension robotic arm encompassing a grab and motorized screwdriver is used to open the irradiation can. A second arm carrying a teflon tube introduces 9M HCI into the can to dissolve the target. A second tube carries the dissolved target via a peristaltic pump to a heated vial where it is evaporated to dryness under a flow of N 2 . A Peltier cooled trap is used to prevent release of HCl fumes into the cell. A motorized syringe pump dispenses 1 mL of 0.1 M HNO 3 to redissolve the digest which is then transferred by peristaltic pump via a hollow fibre filter and auto injector into an Aminex- A5 HPLC column. 166 Dy is eluted from the column in 0.132 M α-HIBA into a heated cyclone flask and evaporated to dryness under a stream of N 2 heated to about 50 deg C. After two days the evaporated Dy/ 166 Ho digest is dissolved in another 1 mL of 0.1 M HNO 3 and injected onto the HPLC column. 166 Ho is collected in 20-25 mL of α-HIBA and evaporated to dryness as before at about 400 C to ensure complete decomposition of the α-HIBA. The product is finally dissolved in about I mL of 0.1 M HCI and pumped through a 0.22 μM filter to a product vial

  17. Our first clinical experience with radiosynoviorthesis by means of 166Ho-holmium-boro-macroaggregates

    International Nuclear Information System (INIS)

    Kraft, O.; Ullmann, V.; Kasparek, R.; Melichar, F.; Kropacek, M.; Mirzajevova, M.

    2005-01-01

    In this paper, we evaluate the therapeutic and adverse effects of the application of 166- holmium-boro-macroaggregates (HMBA) in radiosynovectomy (RSO) of the knees. We assessed the efficacy and safety of 166H o-HBMA in a prospective clinical trial in patients suffering from chronic synovitis. An effective component of radiopharmaceutical 166H o-boro-macroaggregates is radionuclide 166H o which has both b-emission and g-emission. The physical half-life time of 166H o is 26.8 hours. After application of the radiopharmaceutical into a joint cavity, the effect of b-emission causes radiation necrosis of pathologically changed (inflamed) synovial membrane. From 15 april 2005, we have started RSO of knees by means of new radiopharmaceutical 166H o-boro-macroaggregates in patients with gonarthrosis, rheumatoid arthritis, chronic synovitis, psoriatic arthritis, gout arthropathy. Seventeen intra-articular injections were performed in fifteen patients receiving a mean activity of 972 MBq (range: 904.1057 MBq) 166H o-HMBA. The patients were hospitalized for three days. Side effects were evaluated during hospital stay and after 6.8 weeks. Static scintigraphy of knee joints and measurements of blood radioactivity were performed. Therapeutic effects were evaluated after 6.8 weeks. In 2 hours and 2 days after application, we proved, by means of knee and inguinal scintigraphy, only insignificant radiopharmaceutical leakage from the joint cavity to the inguinal lymph nodes in four patients. In treated patients, no serious adverse effects occurred. Nine patients were without complaints; 4 patients had slight knee exudation and 2 patients had great exudation. Therapeutic effects after 6.8 weeks were as follows: 2 patients were without pain, 9 with lower pain, 3 with the same pain and 1 patient with increased pain. Joint motion was improved in 7 patients, remained the same in 7 patients and was impaired in 1 patient. Analgesics consumption was lower in 5 patients, the same in 9

  18. Therapeutic application of new holmium-166 chitosan complex in malignant and benign diseases

    International Nuclear Information System (INIS)

    Park, K.B.; Kim, Y.M.; Shin, B.C.; Kim, J.R.; Ryu, J.M.; Lim, S.M.

    1998-01-01

    The new holmium-166 chitosan complex ( 166 Ho-CHICO, DW- 166 HC) was prepared by reacting the aqueous acidic solution of chitosan with 166 Ho(NO 3 ) 3 at room temperature with quantitative labelling yield. The progress of the reaction and labelling yield were determined by instant this layer chromatography using silicic acid impregnated glass fiber (ITLC-SA) and developing solvent of MeOH:H 2 O:HAC (49:49:2). The high labelling yield of more than 99% was obtained by reacting chitosan solution (35 mg/4 ml) with 166 Ho(NO 3 ) 3 in which 7 mg of 165 Ho+ 166 Ho were contained as a maximum content. The labelling yield was highly dependent on the pH of the chitosan solution. The optimal labelling could be obtained at pH 2.5∼3.5 The characteristics of 166 Ho-CHICO were similar to those of chitosan, which is biocompatible, biodegradable, non-toxic, soluble and viscous in acidic condition but geltatinuous at pH 6.0 and precipitating in alkaline conditions. 166 Ho-CHICO can be easily prepared by reconstituting freeze-dried chitosan (kit A) with 166 Ho(NO 3 ) 3 solution (kit B) just prior to use. After intrahepatic administration of 166 Ho-CHICO to male rats, the radioactivity concentrations in blood were low and the cumulative urinary and fecal excretion over a period of 0 to 72 hours were 0.53% and 0.54%, respectively. the radioactivity concentration in tissues and the whole-body autoradiography images showed that most of the administered radioactivity was localized at the administered site, and only slight radioactivity was detected from the liver, spleen, lungs, and bones. An autoradiograph after intratumoral administration of 166 Ho-CHICO showed that radioactivity was localized at the administered site of the lesion without distribution to other organs and tissues. A biodistribution study in normal rabbits with 166 Ho-CHICO showed that most of the radioactivities were retained in the knee joint with negligible extra leakage at 72 hours after intra

  19. Preparation of .sup.166./sup.Ho-Macroaggregates and .sup.166./sup.Ho-Chitosan for the Radiotherapy

    Czech Academy of Sciences Publication Activity Database

    Kropáček, Martin; Melichar, František; Mirzajevová, Marcela

    2002-01-01

    Roč. 29, č. 2 (2002), s. 382 ISSN 1619-7070 R&D Projects: GA MZd NM6828; GA AV ČR KSK4055109 Keywords : Holmium-166 * 166 Ho-macroaggregates * 166 Ho-chitosan Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  20. Study on the preparation of 166Ho-patch for a skin cancer treatment

    International Nuclear Information System (INIS)

    Kim, Y. M.; Kim, K. H.; Han, K. H.; Park, E. W.; Shin, B. C.; Park, K. B.; Lee, J. D.

    1998-01-01

    Radioactive patch containing holmium-166 has been developed for skin cancer treatment, and then applied to animal model and patients with malignant skin cancer. 165Ho-Patch prepared by dissolving polyurethane and 165 Ho(NO 3 ) 3 ·5H 2 O in mixing solvent of DMF and THF and casting on aluminium dish was irradiated in ''HANARO'' reactor ( Φth = 1.25 X 1013 n/cm 2 '·sec, power = 15 MW), which results in preparing 166 Ho-Patch emitting β energy of Max. 1.86 MeV (51 %), 1.78 MeV (48 %), mean 0.67 MeV and low γ energy. The 166 Ho-Patch specially designed was applied to the superficial skin cancers. Their efficacy and safety have been investigated for several months. Radioactive patch was ready to prepare by post-irradiation without special danger by radioactive material. Skin tumor could be successfully treated with 166 Ho-Patch in animal model and patients. In animal model and patients, the world's first noninvasive 166Ho-Patch readily prepared by post-irradiation proved to be safe and effective in treatment for skin cancer

  1. Microspheres of polyester loaded with Holmium-165: effect of gamma irradiation on the polymeric structure

    International Nuclear Information System (INIS)

    Azevedo, Mariangela de Burgos M. de; Pires, Geovanna; Lira, Rafael A. de; Geraldes, Adriana N.; Nascimento, Nanci; Melo, Vitor Hugo Soares de; Kodama, Yasko

    2011-01-01

    Biodegradable polymers containing radioactive isotopes have potential applications as delivery vehicles of beta radiation to the cancer tumors by brachytherapy. 166-Ho is an example of such radioisotope emitting high-energy beta particles, and also its gamma rays allow nuclear imaging in everywhere is applied. Among the biodegradable polymers, different types of poly(lactide) have been investigated in our laboratory, and poly(L-lactide) (PLLA) was used as substrate to prepare microparticles loaded with holmium acetylacetonate HoAcAc (PLLA-HoAcAc-MP). The aim of this study was to evaluate the stability of these microparticles to gamma radiation. The PLLA-HoAcAc-MP were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP, and their stability studied out with gamma radiation of 25, 50 and 100 kGy doses. MP were characterized before and after irradiation by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), X-ray diffraction (XRD) and con focal laser scanning microscopy (CLSM). Preliminary results showed that gamma radiation did not damage morphologically the prepared PLLA-HoAcAc-MP in the dose range studied, and this procedure may be an important tool for knowing the stabilities of the polymers studied as MP for possible application in brachytherapy. (author)

  2. Preparation of 166 Dy/166 Ho-Macro aggregates as an In vivo generator system for the treatment of arthrophaties

    International Nuclear Information System (INIS)

    Aldama A, T.K.

    2003-01-01

    The present work reports the obtention of macro aggregates of hydroxides of Dysprosium-166/Holmium-166 ( 166 Dy/ 166 Ho-MH), as a generator system in vivo to be used in the treatment of arthritis rheumatoid. The 166 Dy was obtained by neutron irradiation of 166 DyO 3 (enriched to 98.45%) by 20 h in the TRIGA Mark III Reactor and 50 h of decay, to the oxide of 166 Dy/ 166 Ho formed, it was added HCl 0.12 N to obtain a final volume of 3.5 ml of solution of 166 Dy/ 166 Ho chloride. The solution of 166D yCl 3 solution was obtained with an activity of 3.502 mCi (129 MBq), appropriate for the preparation of the radiopharmaceutical 166 Dy/ 166 Ho-MH. The separation of the 166 Dy from the 166 Ho, was carried out by chromatography in an cation exchange column, gaining an appropriate separation, obtaining a 166 Dy with a radionuclide purity greater than 90%. The 166 Dy/ 166 Ho-MH were prepared by addition to the solution of 166 DyCI 3 NaOH 0.5 N low ultrasonic bath with later centrifugation, decanted and resuspension in saline solution, obtaining a radiopharmaceutical with a generator system 166 Dy/ 166 Ho with particles of size average of 3 μm, in form of 166 Dy / 166 Ho-MH. Under these conditions, it was obtained a radiochemical yield greater than 99%. The microscopic analysis and of filtration showed that the formulation doesn't present particles smaller than to 1 μm, neither greater to 50 μm, which will allow, the quick phagocytosis for the synoviocytes of the synovial membrane, and by consequence, an homogeneous distribution of the radiation dose could exist. The sedimentation velocity for the formulated suspension is of 0.04 cm/min that it will allow the administration of homogeneous activities of the radiopharmaceutical, to the no deposit in the injection devices. The studies of stability in vitro indicate us that inside the articulation, the particles won't probably reduce its size neither their radiochemical purity, for that the flight extra articular will be

  3. Preparation of {sup 166} Dy/{sup 166} Ho-Macro aggregates as an In vivo generator system for the treatment of arthrophaties; Preparacion de {sup 166} Dy/{sup 166} Ho-Macro agregados como un sistema de generador In vivo para el tratamiento de artropatias

    Energy Technology Data Exchange (ETDEWEB)

    Aldama A, T.K

    2003-07-01

    The present work reports the obtention of macro aggregates of hydroxides of Dysprosium-166/Holmium-166 ({sup 166} Dy/{sup 166} Ho-MH), as a generator system in vivo to be used in the treatment of arthritis rheumatoid. The {sup 166} Dy was obtained by neutron irradiation of {sup 166} DyO{sub 3} (enriched to 98.45%) by 20 h in the TRIGA Mark III Reactor and 50 h of decay, to the oxide of {sup 166} Dy/{sup 166} Ho formed, it was added HCl 0.12 N to obtain a final volume of 3.5 ml of solution of {sup 166} Dy/{sup 166} Ho chloride. The solution of {sup 166D}yCl{sub 3} solution was obtained with an activity of 3.502 mCi (129 MBq), appropriate for the preparation of the radiopharmaceutical {sup 166} Dy/{sup 166} Ho-MH. The separation of the {sup 166} Dy from the {sup 166} Ho, was carried out by chromatography in an cation exchange column, gaining an appropriate separation, obtaining a {sup 166} Dy with a radionuclide purity greater than 90%. The {sup 166} Dy/{sup 166} Ho-MH were prepared by addition to the solution of {sup 166} DyCI{sub 3} NaOH 0.5 N low ultrasonic bath with later centrifugation, decanted and resuspension in saline solution, obtaining a radiopharmaceutical with a generator system {sup 166} Dy/ {sup 166} Ho with particles of size average of 3 {mu}m, in form of {sup 166} Dy / {sup 166} Ho-MH. Under these conditions, it was obtained a radiochemical yield greater than 99%. The microscopic analysis and of filtration showed that the formulation doesn't present particles smaller than to 1 {mu}m, neither greater to 50 {mu}m, which will allow, the quick phagocytosis for the synoviocytes of the synovial membrane, and by consequence, an homogeneous distribution of the radiation dose could exist. The sedimentation velocity for the formulated suspension is of 0.04 cm/min that it will allow the administration of homogeneous activities of the radiopharmaceutical, to the no deposit in the injection devices. The studies of stability in vitro indicate us that inside

  4. Preparation of {sup 166} Dy/{sup 166} Ho-Macro aggregates as an In vivo generator system for the treatment of arthrophaties; Preparacion de {sup 166} Dy/{sup 166} Ho-Macro agregados como un sistema de generador In vivo para el tratamiento de artropatias

    Energy Technology Data Exchange (ETDEWEB)

    Aldama A, T K

    2003-07-01

    The present work reports the obtention of macro aggregates of hydroxides of Dysprosium-166/Holmium-166 ({sup 166} Dy/{sup 166} Ho-MH), as a generator system in vivo to be used in the treatment of arthritis rheumatoid. The {sup 166} Dy was obtained by neutron irradiation of {sup 166} DyO{sub 3} (enriched to 98.45%) by 20 h in the TRIGA Mark III Reactor and 50 h of decay, to the oxide of {sup 166} Dy/{sup 166} Ho formed, it was added HCl 0.12 N to obtain a final volume of 3.5 ml of solution of {sup 166} Dy/{sup 166} Ho chloride. The solution of {sup 166D}yCl{sub 3} solution was obtained with an activity of 3.502 mCi (129 MBq), appropriate for the preparation of the radiopharmaceutical {sup 166} Dy/{sup 166} Ho-MH. The separation of the {sup 166} Dy from the {sup 166} Ho, was carried out by chromatography in an cation exchange column, gaining an appropriate separation, obtaining a {sup 166} Dy with a radionuclide purity greater than 90%. The {sup 166} Dy/{sup 166} Ho-MH were prepared by addition to the solution of {sup 166} DyCI{sub 3} NaOH 0.5 N low ultrasonic bath with later centrifugation, decanted and resuspension in saline solution, obtaining a radiopharmaceutical with a generator system {sup 166} Dy/ {sup 166} Ho with particles of size average of 3 {mu}m, in form of {sup 166} Dy / {sup 166} Ho-MH. Under these conditions, it was obtained a radiochemical yield greater than 99%. The microscopic analysis and of filtration showed that the formulation doesn't present particles smaller than to 1 {mu}m, neither greater to 50 {mu}m, which will allow, the quick phagocytosis for the synoviocytes of the synovial membrane, and by consequence, an homogeneous distribution of the radiation dose could exist. The sedimentation velocity for the formulated suspension is of 0.04 cm/min that it will allow the administration of homogeneous activities of the radiopharmaceutical, to the no deposit in the injection devices. The studies of stability in vitro indicate us that inside the

  5. Cation exchange resins labeled with holmium-166 for treatment of liver malignancy

    International Nuclear Information System (INIS)

    Costa, Renata F.; Osso Junior, Joao A.

    2008-01-01

    The increasing interest in new therapeutic radiopharmaceuticals is prompting investigators to utilize isotopes with more focused capabilities for treating various tumors, reducing the negative effects on neighboring healthy cells. Local radionuclide therapy using radioactive microspheres is a promising therapy for non-operable group of patients suffering from liver malignancies. Many publications have shown the success of this technique. The emphasis in the present work is the resin-based microspheres labeled with 166 Ho. The production of 166 Ho is feasible in the IEA-R1 Reactor at IPEN-CNEN/SP, because it does not need high power and high neutron fluxes. Samples of Ho 2 O 3 were irradiated in selected positions of the nuclear reactor IEA-R1 at IPEN/CNEN-SP. The neutron flux was 1.0 x10 13 n.s -1 .cm -2 for 1 hour. The dissolution of Ho 2 O 3 was studied with different volumes of 0.1M HCl and also varying the heating temperature. The AG50W-X8 200-400 mesh and CM Sephadex C-25 cation exchange resins were labeled with 166 Ho. The retention of 166 Ho in the resins was studied and also its stability. The results of the dissolution experiments of Ho 2 O 3 showed that there is a direct relation between the increasing volumes needed to dissolve higher masses, and also the positive effect of raising the temperature. The results show very good retention of 166 Ho in both columns, even when high volumes of 0.1M HCl are passed through the column containing the resins and its good stability towards saline solution, PBS solution and glucose.Although the resins employed in this work did not have the right particle size (20-50μm), the chemical behavior showed the very good labeling of the resins with 166 Ho, and its stability. (author)

  6. Radiosynoviorthesis of knees by means of 166Ho-holmium-boro-macroaggregates.

    Science.gov (United States)

    Kraft, Otakar; Kaspárek, Richard; Ullmann, Vojtech; Melichar, Frantisek; Kropácek, Martin; Mirzajevova, Marcela

    2007-04-01

    The aim of this study was to evaluate adverse and therapeutic effects of applicated holmium-boro-macroaggregates (HBMAs) in the radiosynoviorthesis (RSO) of knees in patients suffering from chronic synovitis. We started RSO of the knees by means of a new radiopharmaceutical (RF) HBMA in patients with gonarthrosis, rheumatoid arthritis, chronic synovitis, psoriatic arthritis, and gout arthropathy. Seventeen (17) intra-articular injections were performed in 15 patients who were receiving a mean activity of 972 MBq (range, 904-1057) of 166Ho-HBMA. Patient inclusion to the study followed a series of inclusion and exclusion criterions. The patients were hospitalized for 3 days. Side-effects were evaluated during their hospital stay and again after 6-8 weeks. Static scintigraphy of knee joints and measurements of blood radioactivity were performed. Therapeutic effects were evaluated after 6-8 weeks and at 6 months. In 2 hours and 2 days following the application, we proved, by means of knee and inguinal scintigraphy, only insignificant radiopharmaceutical leakage from the joint cavity to the inguinal lymph nodes in 4 patients. In the treated patients, no serious adverse effects occurred. Nine (9) patients were without complaints, 4 patients had slight knee exudation, and 2 patients had great exudation. Therapeutic effects were as follows: 2 patients were without pain, 9 were with lower pain, 3 were with the same pain, and 1 patient was with increased pain. Joint motion was improved in 7 patients, remained the same in 7 patients, and was impaired in 1 patient. Analgesics consumption was lower in 5 patients, the same in 9 patients, and greater in 1 patient. Knee exudation was absent in 2 patients, lower in 4 patients, the same in 6 patients, and greater in 3 patients. In 3 patients it was necessary to do surgical RSO. This RF can extend the range of clinically used radiopharmaceuticals for RSO and to supplement space between 90Y with high energy and 186Re with 169Er with

  7. In vitro study of morphological and chemical modification threshold of bovine dental enamel irradiated by the holmium laser

    International Nuclear Information System (INIS)

    Eduardo, Patricia Lerro de Paula

    2001-01-01

    The aim of this study is to investigate the Ho:YLF laser effects on the dental enamel surface with regards to its morphology, thermal variations during its irradiation in the pulp chamber and its increased resistance to demineralization through quantitative analysis of calcium and phosphorous atoms reactive concentrations in samples. Twenty samples of bovine enamel were used and divided in four groups: control - acidulated phosphate fluoride (APF) application followed by demineralization treatment with lactic acid; irradiation with Ho:YLF laser (100 J/cm 2 ) followed by APF topic application and demineralization treatment with lactic acid; irradiation with Ho:YLF laser (350 J/cm 2 ) followed by APF topic application and demineralization treatment with lactic acid: and irradiation with Ho:YLF laser ( 450 J/cm 2 ) followed by APF topic application and demineralization treatment with lactic acid. Ali samples were quantified according to their calcium and phosphorous atoms relative concentrations before and after the treatments above. X-Ray fluorescence spectrochemical analysis and scanning electron microscopy were carried out. It was observed an increase on the calcium and phosphorous atoms concentration ratio and therefore the enamel demineralization reduction as a result of the lactic acid treatment in the samples irradiated with the holmium laser followed by the APF application. In order to evaluate the feasibility of this study for clinical purposes, morphological changes caused by the holmium laser irradiation were analyzed. Such modifications were characterized by melted and re-solidified regions of the enamel with consequent changes on its permeability and solubility. Temperature changes of ten human pre-molars teeth irradiated with 350 J/cm 2 and 450 J/cm 2 were also monitored in the pulp chamber in real time. Temperature increases over 4,20 C did not occur. The results obtained from this study along with the results from previous researches developed at

  8. Labeling of biotin with 166Dy/166Ho as a stable in vivo generator system

    International Nuclear Information System (INIS)

    Ferro-Flores, G.; Monroy-Guzman, F.; Tendilla, J.I.; Garcia-Salinas, L.; Villarreal-Barajas, J.E.; Arteaga-Murphy, C.

    2002-01-01

    Biotin (cis-tetrahydro-2-oxothieno[3,4-d]imidazoline-4-valeric acid) is a 244 Da vitamin found in low concentration in blood and tissue (vitamin H). The aim of this work was to synthesize 166 Dy/ 166 Ho-DTPA-bisBiotin to evaluate its potential as a new radiopharmaceutical for targeted radiotherapy. Dysprosium-166/ holmium-166 chloride was obtained by neutron irradiation of 20 mg of enriched Dy 2 O 3 ( 164 Dy, 99 %, from Oak Ridge NL) in a Triga Mark III reactor at a flux in the central thimble of 3.10 13 n. cm -2 s -1 for 20 h. Following irradiation, the target was allowed to decay for 2 days, then 100 μL of 12 N chloride acid were added and stirred for 1 min. To this solution was added 500 μL of injectable water and the whole was also stirred for 2 min. The average radioactive concentration was 332 MBq/ml. The biotin used in this investigation was covalently conjugated to diethylenetriamine pentaacetic acid (DTPA) through the use of the cyclic anhydride and lysine conjugate to biotin (biocytin) to produce DTPA-α,ω-bis(biocytin amide)(DTPA-bisBiotin). Sterile and apyrogenic V-vial was prepared to contain 2.0 mg (1.9 x 10 -3 mmol) of the DTPA-bisbiotin compound in 1.0 ml of 0.05 M bicarbonate buffer (pH 8.0) and then 20 μL of 166 Dy2Cl3 solution were added to the preparation. Thin Layer Chromatography aluminum cellulose sheets were utilised as the stationary phase and a ternary mixture of methanol:water:ammonium hydroxide (20:40:2) as the mobile phase. 166 Dy/ 166 Ho-DTPA-bisBiotin travelled with the solvent front R f 0.9-1.0 and the Dy +3 /Ho +3 species remained at the origin (R f = 0). The biological integrity of labelled biotin was achieved evaluating its avidity for avidin in an agarose column. Stability studies against dilution were carried out by diluting the radiocomplex solution with saline and with human serum at 310 K. After 10 min and 24 h the radiochemical purity of each 166 Dy/ 166 Ho complex solution was determined by TLC. The complex 166 Dy/ 166

  9. Targeting of liver tumour in rats by selective delivery of holmium-166 loaded microspheres: a biodistribution study

    Energy Technology Data Exchange (ETDEWEB)

    Nijsen, F.; Rook, D.; Zonnenberg, B.; Klerk, J. de; Rijk, P. van; Schip, F. van het [Dept. of Nuclear Medicine, University Medical Center, Utrecht (Netherlands); Brandt, C. [Animal Inst., Utrecht Univ. (Netherlands); Meijer, R. [Dept. of Radiology, Univ. Medical Center, Utrecht (Netherlands); Dullens, H. [Dept. of Pathology, Univ. Medical Center, Utrecht (Netherlands); Hennink, W. [Dept. of Pharmaceutics, Utrecht Univ. (Netherlands)

    2001-06-01

    Intra-arterial administration of beta-emitting particles that become trapped in the vascular bed of a tumour and remain there while delivering high doses, represents a unique approach in the treatment of both primary and metastatic liver tumours. Studies on selective internal radiation therapy of colorectal liver metastases using yttrium-90 glass microspheres have shown encouraging results. This study describes the biodistribution of 40-{mu}m poly lactic acid microspheres loaded with radioactive holmium-166, after intra-arterial administration into the hepatic artery of rats with implanted liver tumours. Radioactivity measurements showed >95% retention of injected activity in the liver and its resident tumour. The average activity detected in other tissues was {<=}0.1%ID/g, with incidental exceptions in the lungs and stomach. Very little {sup 166}Ho activity was detected in kidneys (<0.1%ID/g), thereby indicating the stability of the microspheres in vivo. Tumour targeting was very effective, with a mean tumour to liver ratio of 6.1{+-}2.9 for rats with tumour (n=15) versus 0.7{+-}0.5 for control rats (n=6; P<0.001). These ratios were not significantly affected by the use of adrenaline. Histological analysis showed that five times as many large (>10) and medium-sized (4-9) clusters of microspheres were present within tumour and peritumoural tissue, compared with normal liver. Single microspheres were equally dispersed throughout the tumour, as well as normal liver parenchyma. (orig.)

  10. Stone retropulsion during holmium:YAG lithotripsy.

    Science.gov (United States)

    Lee, Ho; Ryan, R Tres; Teichman, Joel M H; Kim, Jeehyun; Choi, Bernard; Arakeri, Navanit V; Welch, A J

    2003-03-01

    We modeled retropulsion during holmium:YAG lithotripsy on the conservation of momentum, whereby the force of ejected fragment debris off of the calculous surface should equal the force of retropulsion displacing the stone. We tested the hypothesis that retropulsion occurs as a result of ejected stone debris. Uniform calculous phantoms were irradiated with holmium:YAG energy in air and in water. Optical fiber diameter and pulse energy were varied. Motion of the phantom was monitored with high speed video imaging. Laser induced crater volume and geometry were characterized by optical coherence tomography. To determine the direction of plume laser burn paper was irradiated at various incident angles. Retropulsion was greater for phantoms irradiated in air versus water. Retropulsion increased as fiber diameter increased and as pulse energy increased (p <0.001). Crater volumes increased as pulse energy increased (p <0.05) and generally increased as fiber diameter increased. Crater geometry was wide and shallow for larger fibers, and narrow and deeper for smaller fibers. The ejected plume propagated in the direction normal to the burn paper surface regardless of the laser incident angle. Retropulsion increases as pulse energy and optical fiber diameter increase. Vector analysis of the ejected plume and crater geometry explains increased retropulsion using larger optical fibers. Holmium:YAG lithotripsy should be performed with small optical fibers to limit retropulsion.

  11. Preparation of .sup.166./sup.Ho-Macroaggregates and .sup.166./sup.Ho-chitosan for the endoradiotherapy

    Czech Academy of Sciences Publication Activity Database

    Melichar, František; Kropáček, Martin; Eigner-Henke, Kateřina; Křížová, V.; Konopková, M.; Lang, O.; Mirzajevová, Marcela

    2002-01-01

    Roč. 1, č. 2 (2002), s. 314 ISSN 1450-1147. [Abstracts of the Congress of the World Federation of Nuclear Medicine and Biology. 29.09.2002-02.10.2002, Santiago] R&D Projects: GA MZd NM6828; GA AV ČR KSK4055109 Keywords : Holmium-166 * radionuclide synovectomy Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

  12. Separation device of radio lanthanides (DISER)

    International Nuclear Information System (INIS)

    Vera T, A.L.; Monroy G, F.; Vazquez M, J.C.; Jimenez B, F.

    2008-01-01

    At the present time the cancer is one of the main causes of mortality in our country, therefore, its prevention, diagnostic and treatment is of vital importance for those health systems. The treatment of the cancer and other illnesses, starting from monoclonal antibodies, peptides, macro aggregates or marked aminoacids with beta particles emitting radioisotopes, it is an extremely promising field. The radioactive lanthanides: Promethium 149, Terbium 161, Holmium 166 and Lutetium 177 are beta emitting (β), which possess nuclear and chemical properties that have shown their feasibility like radioisotopes of radiotherapeutic use. However, these radioisotopes are not commercially available; to this respect, the Radioactive Materials Research Laboratory (LIMR) of the National Institute of Nuclear Research (ININ), it has developed the methodology of production of these radioisotopes and based on these works, there is designed, built and mounted the Radio lanthanides Separation Device (DISER) able to carry out the radioisotopes production in a routine way. This device is content in a cell that has an auxiliary air service, an extraction system and it is protected with a lead armor-plating of 10 cm. The DISER it is manual and easy of managing. The main function of this equipment is the radio lanthanides separation starting from the extractive chromatography by means of packed columns with a commercial resin (LnSPS) and recovered in the superior and inferior part by fiber glass. The DISER is composed by a main carrousel where the separation columns and the elution recipients are mounted. Also counts with an opening system of irradiation vials, port samples for columns and glass material. The present work presents a detailed description of the DISER, as well as its handling that allows to produce the radioisotopes Promethium-149, Terbium-161, Holmium-166 and Lutetium-177 starting from the separation of its parent elements Neodymium-149, Gadolinium-161, Dysprosium-166 and

  13. Estimation of human absorbed dose for (166)Ho-PAM: comparison with (166)Ho-DOTMP and (166)Ho-TTHMP.

    Science.gov (United States)

    Vaez-Tehrani, Mahdokht; Zolghadri, Samaneh; Yousefnia, Hassan; Afarideh, Hossein

    2016-10-01

    In this study, the human absorbed dose of holmium-166 ((166)Ho)-pamidronate (PAM) as a potential agent for the management of multiple myeloma was estimated. (166)Ho-PAM complex was prepared at optimized conditions and injected into the rats. The equivalent and effective absorbed doses to human organs after injection of the complex were estimated by radiation-absorbed dose assessment resource and methods proposed by Sparks et al based on rat data. The red marrow to other organ absorbed dose ratios were compared with these data for (166)Ho-DOTMP, as the only clinically used (166)Ho bone marrow ablative agent, and (166)Ho-TTHMP. The highest absorbed dose amounts are observed in the bone surface and bone marrow with 1.11 and 0.903 mGy MBq(-1), respectively. Most other organs would receive approximately insignificant absorbed dose. While (166)Ho-PAM demonstrated a higher red marrow to total body absorbed dose ratio than (166)Ho-1,4,7,10-tetraazacyclo dodecane-1,4,7,10 tetra ethylene phosphonic acid (DOTMP) and (166)Ho-triethylene tetramine hexa (methylene phosphonic acid) (TTHMP), the red marrow to most organ absorbed dose ratios for (166)Ho-TTHMP and (166)Ho-PAM are much higher than the ratios for (166)Ho-DOTMP. The result showed that (166)Ho-PAM has significant characteristics than (166)Ho-DOTMP and therefore, this complex can be considered as a good agent for bone marrow ablative therapy. In this work, two separate points have been investigated: (1) human absorbed dose of (166)Ho-PAM, as a potential bone marrow ablative agent, has been estimated; and (2) the complex has been compared with (166)Ho-DOTMP, as the only clinically used bone marrow ablative radiopharmaceutical, showing significant characteristics.

  14. Labeling of biotin with Dy-166/Ho-166 as a stable in vivo generator system

    International Nuclear Information System (INIS)

    Ferro-Flores, G.; Monroy-Guzman, F.; Jimenez-Varela, R.; Tendilla, J.I.; Arteaga-Murphy, C.; Pedraza-Lopez, M.

    2002-01-01

    Aim: Biotin is a vitamin found in low concentration in blood and tissue. In radioimmunodiagnosis and radioimmunotherapy practice, the pre-targeting avidin-biotin strategy has shown that target-to-nontarget radioactivity ratios can be significantly improved. In addition, the biotin content of cancerous tumors is higher than that of normal tissue and it has been found in the cellular nucleus due to a specific transfer of biotin to histones by human serum biotinidase. Because of its nuclear properties, the 166 Dy/ 166 Ho radionuclide pair can be considered as an in vivo generator system. The aim of this work was to synthesize 166 Dy/ 166 Ho-DTPA-bisBiotin to evaluate its potential as a new radiopharmaceutical for targeted radiotherapy. Material and Methods: Dysprosium-166/Holmium-166 chloride was obtained by neutron irradiation of 50 mg of 99% enriched 164 Dy 2 O 3 in a TRIGA Mark III reactor at a flux in the central thimble of 3.10 13 n. cm -2 s -1 for 20 h. Following irradiation, the target was allowed to decay for 2 days, 100 μL of 12 N chloride acid were added and the mixture stirred for 3 min. To this suspension 1.0 mL of injectable water were added and heated for 2 min at 90 0 C. The biotin used in this investigation was diethylenetriaminepentaacetic-α,ω-bis(biocytinamide)(DTPA-bisBiotin, Sigma). Sterile and apyrogenic V-vial was prepared to contain 16.0 mg (1.52 x 10 -4 mmol) of the DTPA-bisBiotin in 4.0 mL of 0.05 M bicarbonate buffer (pH 8.5), then 50 μL of the radiochloride solution were added to the preparation. TLC aluminum cellulose sheets were used as the stationary phase and a ternary mixture of methanol: water: ammonium hydroxide (20:40:2) as the mobile phase. 166 Dy/ 166 Ho-DTPA-bisBiotin traveled with the solvent front R f 0.9-1.0 and the Dy +3 /Ho +3 species remained at the origin (R f 0.0). HPLC reverse phase was also used to evaluate radiochemical purity. The biological integrity of labeled biotin was achieved evaluating its avidity for avidin

  15. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  16. 166Ho-chitosan as a radiation synovectomy agent - biocompatibility study of 166Ho-chitosan in rabbits

    International Nuclear Information System (INIS)

    Kim, Sug Jun; Lee, Soo Yong; Jeon, Dae Geun; Lee Jong Seok

    1997-01-01

    Radiation synovectomy is a noninvasive therapy that has been investigated as an alternative to surgical synovectomy. It is been successfully employed in the treatment of synovitis in rheumatoid arthrits and other inflammatory arthropathies. We developed the 166 Ho-chitosan complex for possible use as a radiation synovectomy agent. Holmium is the more practical isotope based on its higher radioactivity and logner half-life. And isotope based on its higher radioactivity and logner half-life. And chitosan is ideal and suitable particles based on its soluble and biodegradable characteristics. So we investigated the biocompatibility of the 166 Ho-chitosan complex to evaluated the suitability as a radiation synovectomy agent. In this study, we performed in vivo and in vitro stability test and biodistribution test. Our results indicate that 166 Ho-chitosan may be an effective radiopharmaceutical for radiation synovectomy. (author). 30 refs., 7 tabs

  17. Preparation and Quality Control of 166-Ho--Macroaggregates for Radiosynoviorthesis

    Czech Academy of Sciences Publication Activity Database

    Kropáček, Martin; Melichar, František; Šrank, Jiří; Mirzajevová, Marcela; Klejzarová, Michaela; Kraft, O.; Kašpárek, R.; Záhlava, J.; Chodacki, A.

    2007-01-01

    Roč. 22, Č. 3 (2007), s. 450-452 ISSN 1084-9785 R&D Projects: GA AV ČR 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiosynoviorthesis * Holmium-166 * radionuclide synovectomy Subject RIV: FR - Pharmacology ; Medidal Chemistry Impact factor: 1.725, year: 2007

  18. Separation device of radio lanthanides (DISER); Dispositivo de separacion de radiolantanidos (DISER)

    Energy Technology Data Exchange (ETDEWEB)

    Vera T, A.L. [FES-Zaragoza, UNAM, 09000 Mexico D.F. (Mexico); Monroy G, F.; Vazquez M, J.C.; Jimenez B, F. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: veratrevino@hotmail.com

    2008-07-01

    At the present time the cancer is one of the main causes of mortality in our country, therefore, its prevention, diagnostic and treatment is of vital importance for those health systems. The treatment of the cancer and other illnesses, starting from monoclonal antibodies, peptides, macro aggregates or marked aminoacids with beta particles emitting radioisotopes, it is an extremely promising field. The radioactive lanthanides: Promethium 149, Terbium 161, Holmium 166 and Lutetium 177 are beta emitting ({beta}), which possess nuclear and chemical properties that have shown their feasibility like radioisotopes of radiotherapeutic use. However, these radioisotopes are not commercially available; to this respect, the Radioactive Materials Research Laboratory (LIMR) of the National Institute of Nuclear Research (ININ), it has developed the methodology of production of these radioisotopes and based on these works, there is designed, built and mounted the Radio lanthanides Separation Device (DISER) able to carry out the radioisotopes production in a routine way. This device is content in a cell that has an auxiliary air service, an extraction system and it is protected with a lead armor-plating of 10 cm. The DISER it is manual and easy of managing. The main function of this equipment is the radio lanthanides separation starting from the extractive chromatography by means of packed columns with a commercial resin (LnSPS) and recovered in the superior and inferior part by fiber glass. The DISER is composed by a main carrousel where the separation columns and the elution recipients are mounted. Also counts with an opening system of irradiation vials, port samples for columns and glass material. The present work presents a detailed description of the DISER, as well as its handling that allows to produce the radioisotopes Promethium-149, Terbium-161, Holmium-166 and Lutetium-177 starting from the separation of its parent elements Neodymium-149, Gadolinium-161, Dysprosium-166

  19. {sup 166}Ho-chitosan as a radiation synovectomy agent - biocompatibility study of {sup 166}Ho-chitosan in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sug Jun; Lee, Soo Yong; Jeon, Dae Geun; Seok, Lee Jong [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1997-01-01

    Radiation synovectomy is a noninvasive therapy that has been investigated as an alternative to surgical synovectomy. It is been successfully employed in the treatment of synovitis in rheumatoid arthrits and other inflammatory arthropathies. We developed the {sup 166}Ho-chitosan complex for possible use as a radiation synovectomy agent. Holmium is the more practical isotope based on its higher radioactivity and logner half-life. And isotope based on its higher radioactivity and logner half-life. And chitosan is ideal and suitable particles based on its soluble and biodegradable characteristics. So we investigated the biocompatibility of the {sup 166}Ho-chitosan complex to evaluated the suitability as a radiation synovectomy agent. In this study, we performed in vivo and in vitro stability test and biodistribution test. Our results indicate that {sup 166}Ho-chitosan may be an effective radiopharmaceutical for radiation synovectomy. (author). 30 refs., 7 tabs.

  20. {sup 166} Ho-EDTMP in detecting bone metastases: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Achando, S.S.; Fernandes, L.; Herrerias, R.; Muramoto, E.; Almeida, M.A.T.; Pereira, N.S. de; Mengatti, J. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    1995-12-31

    Holmium-166-EDTMP (ethylene-dimine-tetra methylene phosphonic acid) due to its promising biological properties, has proved to be a palliating therapeutic agent for bone cancer in human beings. In a basic medium, {sup 166} Ho-EDTMP can be readily prepared with a complexing molar ratio EDTMP/Ho 4.34. The radiochemical purity of the complex was higher than 98%. The biodistribution in rats and mice, showed a high skeletal uptake, a fast blood clearance and a low soft tissue uptake and a lesion to normal bone ratio equal to 2. (author). 3 refs., 4 tabs.

  1. Laboratory investigation of the efficacy of holmium:YAG laser irradiation in removing intracanal debris

    Science.gov (United States)

    Nuebler-Moritz, Michael; Gutknecht, Norbert; Sailer, Hermann F.; Hering, Peter; Prettl, Wilhelm

    1997-05-01

    Current endodontic therapy involves debridement and disinfection of the root canal by means of mechanical instrumentation and chemical irrigation. However, several studies have shown that these techniques fail to achieve complete cleansing. Recently, lasers have been suggested for use within root canals. This study was conducted to determine the efficacy of Holmium:YAG laser irradiation in removing intracanal debris and smear layer. Root canal surfaces of freshly-extracted human teeth were exposed to pulsed Ho:YAG laser radiation. Subsequently, laser induced structural changes were investigated using scanning electron microscopy. Temperature measurements during irradiation were performed by means of thermocouples. The result of this survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment modalities. However, limitations exist with regard to circumscribed and well-quantified irradiation of root canal surfaces, due to the lack of perpendicular delivery of the laser beam. Additional studies will be required to develop suitable optical transmission systems, in order to achieve complete cleansing and to avoid damage to the periradicular tissues, respectively.

  2. Conduction and stability of holmium titanium oxide thin films grown by atomic layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Castán, H., E-mail: helena@ele.uva.es [Department of Electronic, University of Valladolid, 47011 Valladolid (Spain); García, H.; Dueñas, S.; Bailón, L. [Department of Electronic, University of Valladolid, 47011 Valladolid (Spain); Miranda, E. [Departament d' Enginyería Electrònica, Universitat Autónoma de Barcelona, 08193 Bellaterra (Spain); Kukli, K. [Department of Chemistry, University of Helsinki, FI-00014 Helsinki (Finland); Institute of Physics, University of Tartu, EE-50411,Tartu (Estonia); Kemell, M.; Ritala, M.; Leskelä, M. [Department of Chemistry, University of Helsinki, FI-00014 Helsinki (Finland)

    2015-09-30

    Holmium titanium oxide (HoTiO{sub x}) thin films of variable chemical composition grown by atomic layer deposition are studied in order to assess their suitability as dielectric materials in metal–insulator–metal electronic devices. The correlation between thermal and electrical stabilities as well as the potential usefulness of HoTiO{sub x} as a resistive switching oxide are also explored. It is shown that the layer thickness and the relative holmium content play important roles in the switching behavior of the devices. Cycled current–voltage measurements showed that the resistive switching is bipolar with a resistance window of up to five orders of magnitude. In addition, it is demonstrated that the post-breakdown current–voltage characteristics in HoTiO{sub x} are well described by a power-law model in a wide voltage and current range which extends from the soft to the hard breakdown regimes. - Highlights: • Gate and memory suitabilities of atomic layer deposited holmium titanium oxide. • Holmium titanium oxide exhibits resistive switching. • Layer thickness and holmium content influence the resistive switching. • Low and high resistance regimes follow a power-law model. • The power-law model can be extended to the hard breakdown regime.

  3. Material science as basis for nuclear medicine: Holmium irradiation for radioisotopes production

    Science.gov (United States)

    Usman, Ahmed Rufai; Khandaker, Mayeen Uddin; Haba, Hiromitsu; Otuka, Naohiko

    2018-05-01

    Material Science, being an interdisciplinary field, plays important roles in nuclear science. These applications are seen in weaponry, armoured vehicles, accelerator structure and development, semiconductor detectors, nuclear medicine and many more. Present study presents the applications of some metals in nuclear medicine (radioisotope production). The charged-particle-induced nuclear reactions by using cyclotrons or accelerators have become a very vital feature of the modern nuclear medicine. Realising the importance of excitation functions for the efficient production of medical radionuclides, some very high purity holmium metals are generally prepared or purchased for bombardment in nuclear accelerators. In the present work, various methods to obtain pure holmium for radioisotope production have been discussed while also presenting details of our present studies. From the experimental work of the present studies, some very high purity holmium foils have been used in the work for a comprehensive study of residual radionuclides production cross-sections. The study was performed using a stacked-foil activation technique combined with γ-ray spectrometry. The stack was bombarded with 50.4 MeV alpha particle beam from AVF cyclotron of RI Beam Factory, Nishina Centre for Accelerator-Based Science, RIKEN, Japan. The work produced thulium radionuclides useful in nuclear medicine.

  4. Pulsed liquid jet dissector using holmium: YAG laser - a novel neurosurgical device for brain incision without imparing vessels

    International Nuclear Information System (INIS)

    Hirano, T.; Nakagawa, A.; Jokura, H.; Shirane, R.; Uenohara, H.; Ohyama, H.; Takayama, K.

    2003-01-01

    Neurosurgery has long required a method for dissecting brain tissue without damaging principal vessels and adjacent tissue, so as to prevent neurological complications after operation. In this study we constructed a prototype of such a device and used it in an attempt to resect beagle brain cortex. The prototype device consisted of an optical fiber, a Y adapter, and a nozzle whose internal exit diameter was 100 μm. Cold physiological saline (4 o C) was supplied to it at a rate of 40 ml/h. Pulsed liquid jets were ejected from the nozzle by a pulsed Holmium:YAG) (Ho:YAG) laser at an irradiation energy of 300 mJ/pulse. The profile of the liquid jet was observed with a high-speed camera while changing the distance between the optical fiber end and nozzle exit (equivalent to the Standoff distance). With this device (3 Hz operation), brain dissection of anesthetized beagles was attempted while measuring the local temperature of the target. A histological study of the incised parts was also performed. When the Standoff distance was 24 mm, the liquid jet was emitted straight from the nozzle at a maximum initial velocity of 50 m/s. The brain parenchyma was cut with this device while preserving vessels larger than 200 μm in diameter and keeping the operative field clear. The local temperature rose to no more than 41 o C, below the functional heat damage threshold of brain tissue. Histological findings showed no signs of thermal tissue damage around the dissected margin. The Ho:YAG laser-induced liquid jet dissector can be applied to neurosurgery after incorporating some minor improvements. (author)

  5. Complexation behaviour of DADCA and DAPDA with dysprosium-166/holmium-166 parent daughter system and its potential for use in radioimmunotherapy

    International Nuclear Information System (INIS)

    Orsini, S.; University of Technology, Broadway, NSW; Di Bartolo, N.; Smith, S.; Baker, T.

    1998-01-01

    Full text: A novel approach for the delivery of therapeutic doses from 166 Ho to cancerous tissue is via the decay of its parent, 166 Dy. When designing radioimmunoconjugte, a crucial question is to determine whether the ligand used in the radiolabeling process is capable of holding the 166 Ho on decay of the parent, 166 Dy. In this study, two pendant arm macrocycles 1, 10-Diaza-4, 7, 13, 16-tetraoxacyclooctadecane-N, N'-diacetic acid, (DACDA) and 1, 10-Diaza-4, 7, 13-trioxacyclopentadecane-N, N'-diacetic acid, (DAPDA) that were reported to forms reasonably stable complexes with Dy and Ho, were synthesised. The synthesis of the two pendant arm macrocycles was first attempted using methods outlined by Chang and Rowland. The yields obtained through this method were low (10 % for both ligands) and it was considered important to investigate alternative approaches to the synthesis. The new method involved an alkylation reaction in the presence of acetonitrile and sodium bicarbonate. The method took considerably less time and the yields increased to 88 %. The ligands were characterised using 1 H NMR, 13 C NMR and mass spectrometry. The chemical and radiolytic stabilities of 166 Dy and 166 Ho complexes of the two ligands were investigated at pH = 5 and the ligands potential for use in the in vivo generator system evaluated

  6. Comparing particles for radiosynovectomy labeled with Ho-166

    International Nuclear Information System (INIS)

    Argueelles, M.G.; Luppi Berlanga, I.S.; Torres, E.A.; Pereyra Molina, V.

    2002-01-01

    Aim: Three types of microparticles containing Ho-166 were investigated as potential agents for radiation synovectomy. These are: hydroxyapatite (HA), ferric hydroxide macro-aggregates (FHMA) and polymeric micro-spheres (PM). Labeling was performed by three different methods: coprecipitation, two steps labeling using citrate and irradiation of Ho-165 complexed to acetylacetone (AcAc) incorporated into poly-L-lactic acid spheres (PLA) by the solvent evaporation technique. Material and methods: a coprecipitation technique of holmium hydroxide and ferric hydroxide was used in order to obtain 166 Ho-FHMA. Particle size was determined by optical microscopy and selective filtration (1.2 - 100 μm). Obtainment efficiency of FHMA was always higher than 90%. Radiochemical purity was checked by thin layer chromatography using ITLC/SG and EDTA solution as solvent. In vitro stability studies were performed by incubating labelled particles in either saline, or EDTA solution. Hydroxyapatite particles were prepared from the reaction of calcium nitrate and ammonia phosphate at high pH. By strong heating of the precipitate at 800 0 C, the product becomes largely anhydrous and hardened. The yield of the hydroxyapatite synthesis was always greater than 80%. Particle size range was studied using light microscopy. Labeling was done in two steps: 166Ho-citrate was prepared by adding sufficient citric acid to the 166 Ho-Cl 3 solution. The radioactive solution was added to the particulate suspension stirring continuously. Radiolabelled particles were rinsed and separated by centrifugation. Stable Ho-165, complexed to acetylacetone (AcAc), was incorporated into PLA spheres by the solvent evaporation technique. The particle size distribution of the micro-spheres was determined by electronic microscopy. A X-ray fluorescence technique was used to determine the percentage of 165 Ho-AcAc incorporated in the microspheres by studying standards and prepared PLA spheres. Stability studies were

  7. Magnetodielectric coupling in multiferroic holmium iron garnets

    International Nuclear Information System (INIS)

    Malar Selvi, M.; Chakraborty, Deepannita; Venkateswaran, C.

    2017-01-01

    Single phase magneto-electric multiferroics require a large magnetic or electric field for producing magneto-electric (ME) and magnetodielectric (MD) effects. For utilizing these effects in devices investigations on the room temperature and low field MD studies are necessary. Recently, efforts have been largely devoted to the investigation of rare earth iron garnets. In the physical method, the preparation of rare earth iron garnet requires high sintering temperature and processing time. To solve these problems, ball milling assisted microwave sintering technique is used to prepare nanocrystalline holmium iron garnets (Ho_3Fe_5O_1_2). Magnetic and dielectric properties of the prepared sample are investigated. These properties get enhanced in nanocrystalline form when compared to the bulk. The MD coupling of the prepared sample is evident from the anomaly in the temperature dependent dielectric constant plot and the ME coupling susceptibility is derived from the room temperature MD measurements. - Highlights: • Formation of single phase Holmium iron garnet reported. • Ball milling assisted microwave sintering reduces the sintering temperature and time. • Holmium iron garnet shows enhanced magnetic and dielectric properties. • Pyromagnetic and pyroelectric measurements confirm the magnetoelectric coupling. • Room temperature magnetodielectric measurements show the nonlinear behaviour.

  8. Production of microspheres labeled with holmium-166 for liver cancer therapy: the preliminary experience at IPEN/CNEN-SP

    International Nuclear Information System (INIS)

    Costa, Renata F.; Azevedo, Mariangela B.M.; Nascimento, Nanci; Sene, Frank F.; Martinelli, Jose R.; Osso Junior, Joao A.

    2009-01-01

    Microspheres labeled with therapeutic radionuclides for malignancies of liver are widely used in many countries. The internal radionuclide therapy uses a permanently implanted device, such as Therasphere R or SIR-Spheres R , or a biodegradable device that provides structural support for the radionuclide of choice and causes the tumor reduction. Three different types of material supports have been investigated, i.e., biodegradable polymer-based, glass-based and resin-based microspheres. Nowadays there is a project concerning the labeling of these 3 materials with 166 Ho being developed at IPEN-CNEN/SP and coordinated by the Radiopharmacy Directory. 166 Ho(t 1/2 =26.8 h) is a beta minus emitter (E max =1.84 MeV), with right properties for radiotherapy and can be produced with the low power Brazilian Nuclear Reactor IEA-R1m. The aim of this work is to describe the stage of development of this project. The initial experience used resin-based microspheres, a cation exchange resin labeled with 166 Ho, it showed the essential characteristics for liver therapy. Preliminary results of the preparation of glass-based microspheres labeled with 165 Ho showed that 5% of Ho 2 O 3 was incorporated in an aluminosilicate glass, through the process of spheronization by flame, which produced spherical microspheres with 20-40μm particle size. The preparation of biodegradable material, polymer-based microspheres, is in its initial stage and the objective is to prepare and label with 165 Ho different polymer-based microspheres. These combined efforts have been done to offer a national radiotherapeutic product for the the Brazilian nuclear medicine community at fair value and also to offer a viable possibility of treatment for patients affected by liver malignancies. (author)

  9. Production of microspheres labeled with holmium-166 for liver cancer therapy: the preliminary experience at IPEN/CNEN-SP

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Renata F.; Azevedo, Mariangela B.M.; Nascimento, Nanci; Sene, Frank F.; Martinelli, Jose R.; Osso Junior, Joao A., E-mail: renatafcosta@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    Microspheres labeled with therapeutic radionuclides for malignancies of liver are widely used in many countries. The internal radionuclide therapy uses a permanently implanted device, such as Therasphere{sup R} or SIR-Spheres{sup R}, or a biodegradable device that provides structural support for the radionuclide of choice and causes the tumor reduction. Three different types of material supports have been investigated, i.e., biodegradable polymer-based, glass-based and resin-based microspheres. Nowadays there is a project concerning the labeling of these 3 materials with {sup 166}Ho being developed at IPEN-CNEN/SP and coordinated by the Radiopharmacy Directory. {sup 166}Ho(t{sub 1/2}=26.8 h) is a beta minus emitter (E{sub max}=1.84 MeV), with right properties for radiotherapy and can be produced with the low power Brazilian Nuclear Reactor IEA-R1m. The aim of this work is to describe the stage of development of this project. The initial experience used resin-based microspheres, a cation exchange resin labeled with {sup 166}Ho, it showed the essential characteristics for liver therapy. Preliminary results of the preparation of glass-based microspheres labeled with {sup 165}Ho showed that 5% of Ho{sub 2}O{sub 3} was incorporated in an aluminosilicate glass, through the process of spheronization by flame, which produced spherical microspheres with 20-40mum particle size. The preparation of biodegradable material, polymer-based microspheres, is in its initial stage and the objective is to prepare and label with {sup 165}Ho different polymer-based microspheres. These combined efforts have been done to offer a national radiotherapeutic product for the the Brazilian nuclear medicine community at fair value and also to offer a viable possibility of treatment for patients affected by liver malignancies. (author)

  10. Radiosynoviorthesis of Knees by Means of 166Ho-Holmium-Boro-Macroaggregates

    Czech Academy of Sciences Publication Activity Database

    Kraft, O.; Kašpárek, R.; Ullmann, V.; Melichar, František; Kropáček, Martin; Mirzajevová, Marcela

    2007-01-01

    Roč. 22, č. 2 (2007), s. 296-302 ISSN 1084-9785 R&D Projects: GA AV ČR 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiosynoviorthesis * radionuclide synovectomy * 166Ho Subject RIV: FR - Pharmacology ; Medidal Chemistry Impact factor: 1.725, year: 2007

  11. In vitro study of morphological and chemical modification threshold of bovine dental enamel irradiated by the holmium laser; Estudo in vitro das alteracoes morfologicas e quimicas do esmalte dental bovino irradiado pelo laser de holmio

    Energy Technology Data Exchange (ETDEWEB)

    Eduardo, Patricia Lerro de Paula

    2001-07-01

    The aim of this study is to investigate the Ho:YLF laser effects on the dental enamel surface with regards to its morphology, thermal variations during its irradiation in the pulp chamber and its increased resistance to demineralization through quantitative analysis of calcium and phosphorous atoms reactive concentrations in samples. Twenty samples of bovine enamel were used and divided in four groups: control - acidulated phosphate fluoride (APF) application followed by demineralization treatment with lactic acid; irradiation with Ho:YLF laser (100 J/cm{sup 2}) followed by APF topic application and demineralization treatment with lactic acid; irradiation with Ho:YLF laser (350 J/cm{sup 2}) followed by APF topic application and demineralization treatment with lactic acid: and irradiation with Ho:YLF laser ( 450 J/cm{sup 2}) followed by APF topic application and demineralization treatment with lactic acid. Ali samples were quantified according to their calcium and phosphorous atoms relative concentrations before and after the treatments above. X-Ray fluorescence spectrochemical analysis and scanning electron microscopy were carried out. It was observed an increase on the calcium and phosphorous atoms concentration ratio and therefore the enamel demineralization reduction as a result of the lactic acid treatment in the samples irradiated with the holmium laser followed by the APF application. In order to evaluate the feasibility of this study for clinical purposes, morphological changes caused by the holmium laser irradiation were analyzed. Such modifications were characterized by melted and re-solidified regions of the enamel with consequent changes on its permeability and solubility. Temperature changes of ten human pre-molars teeth irradiated with 350 J/cm{sup 2} and 450 J/cm{sup 2} were also monitored in the pulp chamber in real time. Temperature increases over 4,20 C did not occur. The results obtained from this study along with the results from previous

  12. Irradiation device

    International Nuclear Information System (INIS)

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  13. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    International Nuclear Information System (INIS)

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de; Osso Junior, Joao A.; Martinelli, Jose R.

    2011-01-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 ± 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  14. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia; Osso Junior, Joao A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia; Martinelli, Jose R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Ciencias e Tecnologia de Materiais

    2011-07-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 {+-} 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  15. Safety of holmium laser prostatectomy in patients with cardiac pacemaker implant

    Directory of Open Access Journals (Sweden)

    Narmada P Gupta

    2006-01-01

    Full Text Available Objectives: The use of the standard monopolar electrocautery is associated with significant risks of implant malfunction in patients on a cardiac pacemaker. It is also associated with a risk of adverse cardiac events due to blood loss and fluid absorption. The properties of the holmium laser prevent the occurrence of these adverse events. We report the successful use of this technology in resecting the gland in patients on a permanent cardiac pacemaker implant. MATERIALS AND Methods: Six patients with permanent cardiac pacemaker implant were treated with holmium laser resection of prostate over a period of two years. Treated patients had bothersome prostatic symptoms and failed to respond to medical therapy. All patients were operated under spinal anesthesia using a high power VersaPulse ® PowerSuiteTM Holmium laser source. Normal saline was used as irrigant. Intravesical tissue morcellator was also used to remove the larger fragments in two of the patients. Results : Median patient age was 60 years (range 56-73 and median prostate volume was 40cc (range 20-48cc. None of the patient required blood transfusion or had significant hyponatremia or Transurethral resection syndrome. No patients had any pacemaker malfunction or hemodynamic instability during the procedure or in immediate postoperative period. Improvement in maximum urine flow rate was observed from an average of 7 ml/sec in preoperative period to 22 ml/sec postoperatively at 3 month followup. Conclusions: Holmium laser prostatectomy offers the ideal modality of surgery in patients on a cardiac pacemaker. It helps to avoid additional preparation and minimizes the risk of device malfunction and adverse post operative events.

  16. Magnetic structure of holmium-yttrium superlattices

    DEFF Research Database (Denmark)

    Jehan, D.A.; McMorrow, D.F.; Cowley, R.A.

    1993-01-01

    We present the results of a study of the chemical and magnetic structures of a series of holmium-yttrium superlattices and a 5000 angstrom film of holmium, all grown by molecular-beam epitaxy. By combining the results of high-resolution x-ray diffraction with detailed modeling, we show...... that the superlattices have high crystallographic integrity: the structural coherence length parallel to the growth direction is typically almost-equal-to 2000 angstrom, while the interfaces between the two elements are well defined and extend over approximately four lattice planes. The magnetic structures were...... determined using neutron-scattering techniques. The moments on the Ho3+ ions in the superlattices form a basal-plane helix. From an analysis of the superlattice structure factors of the primary magnetic satellites, we are able to determine separately the contributions made by the holmium and yttrium...

  17. Microspheres of poly(ε-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    International Nuclear Information System (INIS)

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de

    2011-01-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho 2 O 3 . Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  18. Microspheres of poly({epsilon}-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    Energy Technology Data Exchange (ETDEWEB)

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho{sub 2}O{sub 3}. Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  19. Evaluation of the therapeutic effect of hydroxyapatite particles labeled with Ho166 in rats with acute and chronic arthritis

    International Nuclear Information System (INIS)

    Mendoza Lopez, Patricia

    2002-01-01

    The therapeutic effect of an intraarticular injection of hydroxyapatite particles labeled with Holmium-166 ( Ho 166 HA) was evaluated. For this evaluation 72 antigen-induced arthritis rats; the arthritis was induced by an intraarticular injection of a suspension of ovoalbumin and Freund's adjuvant complete. The 72 rats were divided in three groups: control group, acute arthritis group and chronic arthritis group. The evaluation of the therapeutic effect was achieved by the measuring of the perimeter of the arthritic knee joint in different days after the intraarticular injection of 0,5 μCi of Ho 166 -HA (day 0, 4, 9, 14, 19, 30). Also a biological distribution study was done at 4, 24 and 48 hours in different organs, through the counting of its radiation. The results of the biological distribution showed that a very high percent of the injected activity remains inside the joint, with minimal activity in other organs, which indicates that the extra articular leakage is very low. The evaluation of the articular perimeter, demonstrated that Ho 166 -HA has a therapeutic effect , which was shown by comparing the control group (6.42 ±0.43 cm right knee; 6.14 ±0.31 cm left knee) with the acute arthritis group (5.11 ±0.3 cm right knee; 4.95 ±0.39 cm left knee) with significantly statistical values (p≤0,01); also the control group was compared with the chronic arthritis group (5.6 ±0.56 cm right knee; 5.47 ±0.51 cm left knee), with significantly statistical values (p≤0,01). This therapeutic effect was evident too when evaluating the measure of the articular perimeter in acute and chronic arthritis groups through the time with significantly statistical values (p≤0,01). In conclusion the hydroxyapatite particles labeled with Holmium-166 are biologically stable in vivo and have a therapeutic effect in the treatment of acute and chronic arthritis in rats [es

  20. A cladding-pumped, tunable holmium doped fiber laser.

    Science.gov (United States)

    Simakov, Nikita; Hemming, Alexander; Clarkson, W Andrew; Haub, John; Carter, Adrian

    2013-11-18

    We present a tunable, high power cladding-pumped holmium doped fiber laser. The laser generated >15 W CW average power across a wavelength range of 2.043 - 2.171 μm, with a maximum output power of 29.7 W at 2.120 μm. The laser also produced 18.2 W when operating at 2.171 µm. To the best of our knowledge this is the highest power operation of a holmium doped laser at a wavelength >2.15 µm. We discuss the significance of background losses and fiber design for achieving efficient operation in holmium doped fibers.

  1. Crystal structure and phase composition of aluminium thin films with holmium additions

    International Nuclear Information System (INIS)

    Koleshko, V.M.; Belitskij, V.F.; Obukhov, V.E.; Rumak, N.V.; Urban, T.P.

    1984-01-01

    The effect of holmium additions on the crystal structure and phase composition of thin aluminium films has been studied. A regularity in grain size changes in aluminium thin films versus the holmium content in them is established. The holmium introduction is shown to result in the appearance of axial texture in the aluminium films, the texture axis being determined by the quantity of the addition. During heat treatment of the aluminium films, containing holmium additions, in the range of low ( approximately 100-200 deg C) annealing temperatures holmium monohydroxide is formed, and at annealing temperatures 300 deg C 0 3 is formed

  2. Use of the holmium:YAG laser in urology

    Science.gov (United States)

    Mattioli, Stefano

    1997-12-01

    The Holmium-YAG is a versatile laser with multiple soft- tissue applications including tissue incision and vaporization, and pulsed-laser applications such as lithotripsy. At 2140 nanometers, the wavelength is highly absorbed by tissue water. Further, like CO2 laser, the Holmium produces immediate tissue vaporization while minimizing deep thermal damage to surrounding tissues. It is an excellent instrument for endopyelotomy, internal urethrotomy, bladder neck incisions and it can be used to resect the prostate. The Holmium creates an acute TUR defect which gives immediate results like the TURP. More than 50 patients were treated from Jan. 1996 to Jan. 1997 for obstructive symptoms due to benign prostatic hyperplasia, bladder neck stricture, urethral stenosis, and superficial bladder tumors.

  3. Proteus mirabilis viability after lithotripsy of struvite calculi

    Science.gov (United States)

    Prabakharan, Sabitha; Teichman, Joel M. H.; Spore, Scott S.; Sabanegh, Edmund; Glickman, Randolph D.; McLean, Robert J. C.

    2000-05-01

    Urinary calculi composed of struvite harbor urease-producing bacteria within the stone. The photothermal mechanism of holmium:YAG lithotripsy is uniquely different than other lithotripsy devices. We postulated that bacterial viability of struvite calculi would be less for calculi fragmented with holmium:YAG irradiation compared to other lithotripsy devices. Human calculi of known struvite composition (greater than 90% magnesium ammonium phosphate hexahydrate) were incubated with Proteus mirabilis. Calculi were fragmented with no lithotripsy (controls), or shock wave, intracorporeal ultrasonic, electrohydraulic, pneumatic, holmium:YAG or pulsed dye laser lithotripsy. After lithotripsy, stone fragments were sonicated and specimens were serially plated for 48 hours at 38 C. Bacterial counts and the rate of bacterial sterilization were compared. Median bacterial counts (colony forming units per ml) were 8 X 106 in controls and 3 X 106 in shock wave, 3 X 107 in ultrasonic, 4 X 105 in electrohydraulic, 8 X 106 in pneumatic, 5 X 104 in holmium:YAG and 1 X 106 in pulsed dye laser lithotripsy, p less than 0.001. The rate of bacterial sterilization was 50% for holmium:YAG lithotripsy treated stones versus 0% for each of the other cohorts, p less than 0.01. P. mirabilis viability is less after holmium:YAG irradiation compared to other lithotripsy devices.

  4. Compact high-field superconducting quadrupole magnet with holmium poles

    Energy Technology Data Exchange (ETDEWEB)

    Barlow, D.B.; Kraus, R.H. Jr.; Lobb, C.T.; Menzel, M.T. (Los Alamos National Lab., NM (United States)); Walstrom, P.L. (Grumman Space Systems, Los Alamos, NM (United States))

    1992-03-15

    A compact high-field superconducting quadrupole magnet was designed and built with poles made of the rare-earth metal holmium. The magnet is intended for use in superconducting coupled-cavity linear accelerators where compact high-field quadrupoles are needed, but where the use of permanent magnets is ruled out because of trapped-flux losses. The magnet has a clear bore diameter of 1.8 cm, outside diameter of 11 cm, length of 11 cm, and pole tip length of 6 cm. The effect of using holmium, a material with a higher saturation field than iron, was investigated by replacing poles made of iron with identical poles made of holmium. The magnet was operated at a temperature of 4.2 K and reached a peak quadrupole field gradient of 355 T/m, a 10% increase over the same magnet with iron poles. This increase in performance is consistent with calculations based on B-H curves that were measured for holmium at 4.2 K. (orig.).

  5. Preparation of 166 Dy/166 Ho DTPA-bis biotin as a system of In vivo generator

    International Nuclear Information System (INIS)

    Jimenez V, M.R.

    2003-01-01

    The objective of this work was to synthesize the complex 166 Dy/ 166 Ho - diethylen triamine pentaacetic-bis Biotin ( 166 Dy/ 166 Ho DTPA-bis Biotin) to evaluate its potential as a new radiopharmaceutical in directed radiotherapy. The Dysprosium-166 was obtained for neutron irradiation of 164 Dy 2 0 3 in the TRIGA Mark III reactor. The labelled was carried out in aqueous solution to p H 8.0 for addition of 166 Dy Cl 3 to the diethylen triamine pentaacetic-α, ω-bis Biotin (DTPA-bis Biotin). The radiochemical purity was determined for HPLC and ITLC. The biological integrity of the marked biotin is evaluated by the biological recognition of the avidin for HPLC - molecular exclusion with and without avidin addition. The studies of stability in vitro were made in dilutions of saline solution to 0.9% and with human serum at 37 C incubated 1 and 24 hours. The complex 166 Dy/ 166 Ho DTPA-bis Biotin was obtained with a radiochemical purity of 99.1 ± 0.6%. The biological recognition of the complex 166 Dy/ 166 Ho DTPA-bis Biotin for the avidin it doesn't affect the labelling procedure. The studies in vitro demonstrated that the 166 Dy/ 166 Ho DTPA-bis Biotin is stable after the dilution in saline solution and in human serum that there is not translocation of the one radionuclide subsequent son to the beta decay of the 166 Dy that could produce the 166 Ho 3+ liberation. The studies of Biodistribution in healthy mice demonstrated that the one complex 166 Dy/ 166 Ho DTPA-bis Biotin have a high renal distribution. In conclusion the radiolabelled biotin in this investigation has the appropriate properties to be used as an In vivo generator system stable for directed radiotherapy. (Author)

  6. Electron beam irradiating device

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, K

    1969-12-20

    The efficiency of an electron beam irradiating device is heightened by improving the irradiation atmosphere and the method of cooling the irradiation window. An irradiation chamber one side of which incorporates the irradiation windows provided at the lower end of the scanner is surrounded by a suitable cooling system such as a coolant piping network so as to cool the interior of the chamber which is provided with circulating means at each corner to circulate and thus cool an inert gas charged therewithin. The inert gas, chosen from a group of such gases which will not deleteriously react with the irradiating equipment, forms a flowing stream across the irradiation window to effect its cooling and does not contaminate the vacuum exhaust system or oxidize the filament when penetrating the equipment through any holes which the foil at the irradiation window may incur during the irradiating procedure.

  7. Holmium:YAG laser stapedotomy: preliminary evaluation

    Science.gov (United States)

    Stubig, Ingrid M.; Reder, Paul A.; Facer, G. W.; Rylander, Henry G.; Welch, Ashley J.

    1993-07-01

    This study investigated the use of a pulsed Holmium:YAG ((lambda) equals 2.09 micrometers ) laser- fiber microsurgical system for laser stapedotomy. This system ablates human stapes bones effectively with minimal thermal damage. The study was designed to determine the effectiveness of the Ho:YAG laser (Schwartz Electro Optics, Inc., Orlando, FL) for stapedotomy and to evaluate temperature changes within the cochlea during the ablation process. Human cadaveric temporal bones were obtained and the stapes portion of the ossicular chain was removed. A 200 micrometers diameter low OH quartz fiber was used to irradiate these stapes bones in an air environment. The laser was pulsed at 2 Hz, 250 microsecond(s) ec pulse width and an irradiance range of 100 - 240 J/cm2 was used to ablate holes in the stapes footplate. The resultant stapedotomies created had smooth 300 micrometers diameter holes with a minimum of circumferential charring. Animal studies in-vivo were carried out in chinchillas to determine the caloric spread within the cochlea. A 0.075 mm Type T thermocouple was placed in the round window. Average temperature change during irradiation of the stapes footplate recorded in the round window was 3.6 degree(s)C. The data suggest that stapedotomy using the Ho:YAG laser can result in a controlled ablation of the stapes footplate with minimal thermal damage to the surrounding stapes. Optical coupling using fiberoptic silica fibers is an ideal method for delivering laser energy to the stapes during stapedotomy.

  8. Development of radiolabelled compound using reactor produced RI - Development of Ho-166 skin patch for treatment of skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Bae [Korea Atomic Energy Research Institute, Taejon (Korea); Ryu, Jei Man [Dong Wha Pharm. Ind. Co., Ltd., Seoul (Korea)

    1999-04-01

    A radioactive patch which can be treat the skin cancer by direct irradiation was prepared by blending Ho(NO{sub 3}){sub 3}, 5H{sub 2}O and polyurethane(PU) and then irradiating with neutron in the nuclear reactor. The blend formation of the film was fonfirmed by FT-IR. Degree of the distribution of holmium and solvent in remaining in the film was determined. Physical properties of the film by thermal analysis, mechanical measurement and surface analysis were characterized, respectively. To evaluate efficacy of the patch, it was applied to the tumor surface of the hairlessmous. Until 6 weeks of the patch treatment 7 mice with skin tumor were cured totally (7/13). And the other nuclear except for holmium was in patch was not detected. Furthermore, the patch was stable at room temperature, 40 deg C and 60 deg C. (author). 17 refs., 13 figs., 9 tabs.

  9. Preparation of {sup 166} Dy/{sup 166} Ho DTPA-bis biotin as a system of In vivo generator; Preparacion de {sup 166} Dy/{sup 166} Ho DTPA-bis biotina como un sistema de generador In vivo

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez V, M.R

    2003-07-01

    The objective of this work was to synthesize the complex {sup 166} Dy/{sup 166} Ho - diethylen triamine pentaacetic-bis Biotin ({sup 166} Dy/{sup 166} Ho DTPA-bis Biotin) to evaluate its potential as a new radiopharmaceutical in directed radiotherapy. The Dysprosium-166 was obtained for neutron irradiation of {sup 164} Dy{sub 2}0{sub 3} in the TRIGA Mark III reactor. The labelled was carried out in aqueous solution to p H 8.0 for addition of {sup 166} Dy Cl{sub 3} to the diethylen triamine pentaacetic-{alpha}, {omega}-bis Biotin (DTPA-bis Biotin). The radiochemical purity was determined for HPLC and ITLC. The biological integrity of the marked biotin is evaluated by the biological recognition of the avidin for HPLC - molecular exclusion with and without avidin addition. The studies of stability in vitro were made in dilutions of saline solution to 0.9% and with human serum at 37 C incubated 1 and 24 hours. The complex {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin was obtained with a radiochemical purity of 99.1 {+-} 0.6%. The biological recognition of the complex {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin for the avidin it doesn't affect the labelling procedure. The studies in vitro demonstrated that the {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin is stable after the dilution in saline solution and in human serum that there is not translocation of the one radionuclide subsequent son to the beta decay of the {sup 166} Dy that could produce the {sup 166} Ho{sup 3+} liberation. The studies of Biodistribution in healthy mice demonstrated that the one complex {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin have a high renal distribution. In conclusion the radiolabelled biotin in this investigation has the appropriate properties to be used as an In vivo generator system stable for directed radiotherapy. (Author)

  10. Preparation of {sup 166} Dy/{sup 166} Ho DTPA-bis biotin as a system of In vivo generator; Preparacion de {sup 166} Dy/{sup 166} Ho DTPA-bis biotina como un sistema de generador In vivo

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez V, M R

    2003-07-01

    The objective of this work was to synthesize the complex {sup 166} Dy/{sup 166} Ho - diethylen triamine pentaacetic-bis Biotin ({sup 166} Dy/{sup 166} Ho DTPA-bis Biotin) to evaluate its potential as a new radiopharmaceutical in directed radiotherapy. The Dysprosium-166 was obtained for neutron irradiation of {sup 164} Dy{sub 2}0{sub 3} in the TRIGA Mark III reactor. The labelled was carried out in aqueous solution to p H 8.0 for addition of {sup 166} Dy Cl{sub 3} to the diethylen triamine pentaacetic-{alpha}, {omega}-bis Biotin (DTPA-bis Biotin). The radiochemical purity was determined for HPLC and ITLC. The biological integrity of the marked biotin is evaluated by the biological recognition of the avidin for HPLC - molecular exclusion with and without avidin addition. The studies of stability in vitro were made in dilutions of saline solution to 0.9% and with human serum at 37 C incubated 1 and 24 hours. The complex {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin was obtained with a radiochemical purity of 99.1 {+-} 0.6%. The biological recognition of the complex {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin for the avidin it doesn't affect the labelling procedure. The studies in vitro demonstrated that the {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin is stable after the dilution in saline solution and in human serum that there is not translocation of the one radionuclide subsequent son to the beta decay of the {sup 166} Dy that could produce the {sup 166} Ho{sup 3+} liberation. The studies of Biodistribution in healthy mice demonstrated that the one complex {sup 166} Dy/{sup 166} Ho DTPA-bis Biotin have a high renal distribution. In conclusion the radiolabelled biotin in this investigation has the appropriate properties to be used as an In vivo generator system stable for directed radiotherapy. (Author)

  11. Structural and optical properties of α-Fe2O3 nanoparticles, influence by holmium ions

    Science.gov (United States)

    Mathevula, L. E.; Noto, L. L.; Mothudi, B. M.; Dhlamini, M. S.

    2018-04-01

    α-Fe2O3 and α-Fe2O3 doped with different concentration of holmium ions were synthesized by a simple sol-gel method. The XRD data confirmed the hexagonal structure of α-Fe2O3 for un-doped and holmium doped samples. The crystallite size was found to be decreasing with increasing holmium concentration. The amount of holmium was quantified using an EDS, which shows an increase in holmium quantity as concentration increases. The UV-Vis measurement shows an absorption edge around 570 nm. The band gap was estimated using the Kubelka-Munk relation and it was found to be fluctuating between 1.94 eV and 2.04 eV. The PL spectra confirmed the effect of holmium ions on luminescence properties of α-Fe2O3 which showed a maximum intensity at 0.1 mol% Holmium, and quenching as the concentration is increased from 0.3 mol% to 0.9 mol%.

  12. Holmium laser enucleation of the prostate hyperplasia: technical aspects

    Directory of Open Access Journals (Sweden)

    P. V. Glybochko

    2015-01-01

    Full Text Available Holmium laser enucleation of the prostate (HoLEP was first described by doctor P.J. Gilling et al. from New Zealand in 1996. The operation involves anatomical dissection of the prostatic tissue off the surgical capsule using a high-powered holmium laser followed by intravesical morsellation. The objective of this article is to explain the techniques for HoLEP.

  13. New irradiation devices at the FRN reactor

    International Nuclear Information System (INIS)

    Stark, W.

    1980-01-01

    In order to fulfill the experimental demands three additional devices were constructed and installed. The first is a vertical irradiation tube in air surrounded by a lead cylinder (in the irradiation position). The second device is a rabbit system ending within the graphite moderator of the thermal column. The third device is so called rotating disk assembly, built to replace the rotary specimen rack

  14. ANTIBACTERIAL PROPERTIES OF HOLMIUM TO CAUSATIVE AGENTS OF SUPPURATIVE -INFLAMMATORY COMPLICATIONS IN PATIENTS WITH TRAUMA

    Directory of Open Access Journals (Sweden)

    Poddubnaya H. N.

    2012-06-01

    Full Text Available Article denotes to determination of antibacterial action of polyoxometalate holmium to causative agents of suppurative-inflammatory process in wounds of patients, which were suffered from trauma. Method of serial dilutions was used for determination of minimal inhibiting concentration (MIC of holmium to staphylococci, enterococci and E. coli. Registration of holmium action shows the strong antibacterial influence to staphylococci and enterococci (MIC of holmium action to staphylococcal and enterococcal strains same 1 10 M, to strains of E.coli – 2,5 10 M. Solutions of holmium don’t have antibacterial action to strains of E.coli.

  15. Investigation of complexes with bone affinity using the In vivo generator system 166 Dy/166 Ho

    International Nuclear Information System (INIS)

    Pedraza L, M.

    2006-01-01

    The importance of this original research lies in the fact that it has proven that the [ 166 Dy]Dy/ 166 Ho-EDTMP in vivo generator system is a stable complex that can be used as a therapeutic radiopharmaceutical. Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. Bone-seeking radiopharmaceuticals such as 166 Ho-DOTMP or 153 Sm-DTMP, have been proposed for delivering ablative radiation doses to marrow in multiple myeloma and other hematological malignancies or have shown excellent results in palliative bone metastasis pain therapy, respectively. As lanthanides have similar chemical characteristics the phosphonate with bone affinity (EDTMP) labeled with Dy/Ho can be used for marrow ablation while causing minimal irradiation to normal organs. This in vivo generator system has not been previously reported. The aim of this research was to label EDTMP (ethylene diamine tetramethylene phosphonate) with 166 Dy/ 166 Ho; to evaluate the in vitro and in vivo stability of both 166 Dy-EDTMP and 166 Ho-EDTMP complexes when the daughter 166 Ho is formed as a dysprosium decay product; to determine the bone marrow cytotoxic and genotoxic effect in mice and to evaluate, by histopathology, the myeloablative potential of the [ 166 Dy]Dy/ 166 Ho-EDTMP in vivo generator system. 166 Dy was obtained by neutron irradiation of enriched 164 Dy 2 O 3 in a TRIGA Mark III reactor. Labeling was carried out in an aqueous phosphate medium at pH 8.0 by addition of 166 DyCl 3 to EDTMP at a molar ratio 1:1.75, with >99 % radiochemical purity, as determined by thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC). In vitro studies demonstrated that 166 Dy/ 166 Ho-EDTMP is unstable after dilution in saline but stable in human serum with no translocation of the daughter nucleus subsequent to β decay of 166 Dy, which could release free 166 Ho 3+ . Biodistribution in mice

  16. Dynamics of pulsed holmium:YAG laser photocoagulation of albumen

    International Nuclear Information System (INIS)

    Pfefer, T.J.; Welch, A.J.

    2000-01-01

    The pulsed holmium:YAG laser (λ = 2.12 μm, τ p = 250 μs) has been investigated as a method for inducing localized coagulation for medical procedures, yet the dynamics of this process are not well understood. In this study, photocoagulation of albumen (egg white) was analysed experimentally and results compared with optical-thermal simulations to investigate a rate process approach to thermal damage and the role of heat conduction and dynamic changes in absorption. The coagulation threshold was determined using probit analysis, and coagulum dynamics were documented with fast flash photography. The nonlinear computational model, which included a Beer's law optical component, a finite difference heat transfer component and an Arrhenius equation-based damage calculation, was verified against data from the literature. Moderate discrepancies between simulation results and our experimental data probably resulted from the use of a laser beam with an irregular spatial profile. This profile produced a lower than expected coagulation threshold and an irregular damage distribution within a millisecond after laser onset. After 1 ms, heat conduction led to smoothing of the coagulum. Simulations indicated that dynamic changes in absorption led to a reduction in surface temperatures. The Arrhenius equation was shown to be effective for simulating transient albumen coagulation during pulsed holmium:YAG laser irradiation. Greater understanding of pulsed laser-tissue interactions may lead to improved treatment outcome and optimization of laser parameters for a variety of medical procedures. (author)

  17. Investigation of complexes with bone affinity using the In vivo generator system {sup 166} Dy/{sup 166} Ho; Investigacion de complejos con afinidad osea utilizando el Sistema de Generador in vivo {sup 166} Dy/{sup 166} Ho

    Energy Technology Data Exchange (ETDEWEB)

    Pedraza L, M

    2006-07-01

    The importance of this original research lies in the fact that it has proven that the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system is a stable complex that can be used as a therapeutic radiopharmaceutical. Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. Bone-seeking radiopharmaceuticals such as {sup 166}Ho-DOTMP or {sup 153}Sm-DTMP, have been proposed for delivering ablative radiation doses to marrow in multiple myeloma and other hematological malignancies or have shown excellent results in palliative bone metastasis pain therapy, respectively. As lanthanides have similar chemical characteristics the phosphonate with bone affinity (EDTMP) labeled with Dy/Ho can be used for marrow ablation while causing minimal irradiation to normal organs. This in vivo generator system has not been previously reported. The aim of this research was to label EDTMP (ethylene diamine tetramethylene phosphonate) with {sup 166}Dy/{sup 166}Ho; to evaluate the in vitro and in vivo stability of both {sup 166}Dy-EDTMP and {sup 166}Ho-EDTMP complexes when the daughter {sup 166}Ho is formed as a dysprosium decay product; to determine the bone marrow cytotoxic and genotoxic effect in mice and to evaluate, by histopathology, the myeloablative potential of the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system. {sup 166}Dy was obtained by neutron irradiation of enriched {sup 164}Dy{sub 2}O{sub 3} in a TRIGA Mark III reactor. Labeling was carried out in an aqueous phosphate medium at pH 8.0 by addition of {sup 166}DyCl{sub 3} to EDTMP at a molar ratio 1:1.75, with >99 % radiochemical purity, as determined by thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC). In vitro studies demonstrated that {sup 166}Dy/{sup 166}Ho-EDTMP is unstable after dilution in saline but stable in human serum with no translocation of the daughter nucleus

  18. Irradiation damage of SiC semiconductor device (I)

    International Nuclear Information System (INIS)

    Park, Ji Yeon; Kim, Weon Ju

    2000-09-01

    This report reviewed the irradiation damage of SiC semiconductor devices and examined a irradiation behavior of SiC single crystal as a pre-examination for evaluation of irradiation behavior of SiC semiconductor devices. The SiC single was crystal irradiated by gamma-beam, N+ ion and electron beam. Annealing examinations of the irradiated specimens also were performed at 500 deg C. N-type 6H-SiC dopped with N+ ion was used and irradiation doses of gamma-beam, N+ion and electron beam were up to 200 Mrad, 1x10 16 N + ions/cm 2 and 3.6 x 10 17 e/cm 2 and 1.08 x 10 18 e/cm 2 , respectively. Irradiation damages were analyzed by the EPR method. Additionally, properties of SiC, information about commercial SiC single crystals and the list of web sites with related to the SiC device were described in the appendix

  19. Irradiation damage of SiC semiconductor device (I)

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Yeon; Kim, Weon Ju

    2000-09-01

    This report reviewed the irradiation damage of SiC semiconductor devices and examined a irradiation behavior of SiC single crystal as a pre-examination for evaluation of irradiation behavior of SiC semiconductor devices. The SiC single was crystal irradiated by gamma-beam, N+ ion and electron beam. Annealing examinations of the irradiated specimens also were performed at 500 deg C. N-type 6H-SiC dopped with N+ ion was used and irradiation doses of gamma-beam, N+ion and electron beam were up to 200 Mrad, 1x10{sup 16} N{sup +} ions/cm{sup 2} and 3.6 x 10{sup 17} e/cm{sup 2} and 1.08 x 10{sup 18} e/cm{sup 2} , respectively. Irradiation damages were analyzed by the EPR method. Additionally, properties of SiC, information about commercial SiC single crystals and the list of web sites with related to the SiC device were described in the appendix.

  20. Investigation of complexes with bone affinity using the In vivo generator system {sup 166} Dy/{sup 166} Ho; Investigacion de complejos con afinidad osea utilizando el Sistema de Generador in vivo {sup 166} Dy/{sup 166} Ho

    Energy Technology Data Exchange (ETDEWEB)

    Pedraza L, M

    2006-07-01

    The importance of this original research lies in the fact that it has proven that the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system is a stable complex that can be used as a therapeutic radiopharmaceutical. Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. Bone-seeking radiopharmaceuticals such as {sup 166}Ho-DOTMP or {sup 153}Sm-DTMP, have been proposed for delivering ablative radiation doses to marrow in multiple myeloma and other hematological malignancies or have shown excellent results in palliative bone metastasis pain therapy, respectively. As lanthanides have similar chemical characteristics the phosphonate with bone affinity (EDTMP) labeled with Dy/Ho can be used for marrow ablation while causing minimal irradiation to normal organs. This in vivo generator system has not been previously reported. The aim of this research was to label EDTMP (ethylene diamine tetramethylene phosphonate) with {sup 166}Dy/{sup 166}Ho; to evaluate the in vitro and in vivo stability of both {sup 166}Dy-EDTMP and {sup 166}Ho-EDTMP complexes when the daughter {sup 166}Ho is formed as a dysprosium decay product; to determine the bone marrow cytotoxic and genotoxic effect in mice and to evaluate, by histopathology, the myeloablative potential of the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system. {sup 166}Dy was obtained by neutron irradiation of enriched {sup 164}Dy{sub 2}O{sub 3} in a TRIGA Mark III reactor. Labeling was carried out in an aqueous phosphate medium at pH 8.0 by addition of {sup 166}DyCl{sub 3} to EDTMP at a molar ratio 1:1.75, with >99 % radiochemical purity, as determined by thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC). In vitro studies demonstrated that {sup 166}Dy/{sup 166}Ho-EDTMP is unstable after dilution in saline but stable in human serum with no translocation of the daughter nucleus

  1. Drug metabolism: Comparison of biodistribution profile of holmium in three different compositions in healthy Wistar rats

    International Nuclear Information System (INIS)

    Cerqueira-Coutinho, Cristal; Vidal, Lluis Pascual; Pinto, Suyene Rocha; Santos-Oliveira, Ralph

    2016-01-01

    Radioisotope holmium is a candidate to be used in cancer treatment and diagnosis. There are different holmium salts and they present distinct solubility and consequently different biodistribution profiles. In this work, we aimed to evaluate the biodistribution profiles of two holmium salts (chloride and sulfate) and holmium nanoparticles (oxide) through an in vivo biodistribution assay using animal model. Samples were labeled with technetium-99m and administered in Wistar rats by retro-orbital route. Holmium chloride is highly soluble in water and it was quickly filtered by the kidneys while holmium sulfate that presents lower solubility in water was mainly found in the liver and the spleen. However, both the salts showed a similar biodistribution profile. On the other hand, holmium oxide showed a very different biodistribution profile since it seemed to interact with all organs. Due to its particle size range (approximately 100 nm) it was not intensively filtered by the kidneys being found in high quantities in many organs, for this reason its use as a nanoradiopharmaceutical could be promising in the oncology field. - Highlights: • This article brings the biodistribution of holmium in 3 different compositions. • The results, as a technical note may help other researchers around the world to elucidate the mechanism (biological behavior) and the best strategy to use holmium as radiopharmaceutical.

  2. Proton irradiation effects in silicon devices

    Energy Technology Data Exchange (ETDEWEB)

    Simoen, E; Vanhellemont, J; Alaerts, A [IMEC, Leuven (Belgium); and others

    1997-03-01

    Proton irradiation effects in silicon devices are studied for components fabricated in various substrates in order to reveal possible hardening effects. The degradation of p-n junction diodes increases in first order proportionally with the fluence, when submitted to 10 MeV proton irradiations in the range 5x10{sup 9} cm{sup -2} to 5x10{sup 11} cm{sup -2}. The damage coefficients for both p- and n-type Czochralski, Float-Zone and epitaxial wafers are reported. Charge-Coupled Devices fabricated in a 1.2 {mu}m CCD-CMOS technology are shown to be quite resistant to 59 MeV H{sup +} irradiations, irrespective of the substrate type. (author)

  3. Dysprosium (holmium) determination in the presence of erbium and dysprosium (holmium, erbium) determination in the presence of cerium

    International Nuclear Information System (INIS)

    Tolubara, A.I.; Kochubej, A.I.; Usatenko, Yu.I.

    1978-01-01

    Effect of salicylic acid upon complex formation in the systems REE - boronsulfoalizarinate, REE - oxine and REE - boronsulfoalizarinate - oxine is investigated. Comparison of optical characteristics of the above systems in the absence and in the presence of salicylic acid is carried out. It is established that in all the cases the effect of salicylic acid depends both on the nature of REE and the ratio of all the components of the system. Under certain conditions the given dependence is observed only for erbium complexes. Extraction-photometric methods of dysprosium and holmium determination in the presence of equal erbium amounts, as well as holmium and erbium determination in the presence of cerium equal amounts is developed

  4. Dysprosium (holmium) determination in the presence of erbium and dysprosium (holmium, erbium) determination in the presence of cerium

    Energy Technology Data Exchange (ETDEWEB)

    Tolubara, A I; Kochubei, A I; Usatenko, Yu I

    1978-01-01

    Effect of salicylic acid upon complex formation in the systems REE - boronsulfoalizarinate, REE - oxine and REE - boronsulfoalizarinate - oxine is investigated. Comparison of optical characteristics of the above systems in the absence and in the presence of salicylic acid is carried out. It is established that in all the cases the effect of salicylic acid depends both on the nature of REE and the ratio of all the components of the system. Under certain conditions the given dependence is observed only for erbium complexes. Extraction-photometric methods of dysprosium and holmium determination in the presence of equal erbium amounts, as well as holmium and erbium determination in the presence of cerium equal amounts is developed.

  5. Degradation of SiGe devices by proton irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Ohyama, Hidenori; Hayama, Kiyoteru [Kumamoto National Coll. of Technology, Nishigoshi (Japan); Vanhellemont, J; Takami, Yasukiyo; Sunaga, Hiromi; Nashiyama, Isamu; Uwatoko, Yoshiya; Poortmans, J; Caymax, M

    1997-03-01

    The degradation and recovery behavior of strained Si{sub 1-x}Ge{sub x} diodes and heterojunction bipolar transistors (HBTs) by irradiated by protons are studied. The degradation of device performance and the generation of lattice defects are reported as a function of fluence and germanium content and also compared extensively with previous results obtained on electron and neutron irradiated devices. In order to study the recovery behavior of the irradiated devices, isochronal annealing is performed. The radiation source dependence of the degradation is discussed taking into account the number of knock-on atoms and the nonionizing energy loss (NIEL). (author)

  6. Thermal property of holmium doped lithium lead borate glasses

    Science.gov (United States)

    Usharani, V. L.; Eraiah, B.

    2018-04-01

    The new glass system of holmium doped lithium lead borate glasses were prepared by conventional melt quenching technique. The thermal stability of the different compositions of Ho3+ ions doped lithium lead borate glasses were studied by using TG-DTA. The Tg values are ranging from 439 to 444 °C with respect to the holmium concentration. Physical parameters like polaron radius(rp), inter-nuclear distance (ri), field strength (F) and polarizability (αm) of oxide ions were calculated using appropriate formulae.

  7. Genotoxic and cytotoxic damage by the therapeutic radiopharmaceutical [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP as in vivo generator system; Dano genotoxico y citotoxico por el radiofarmaco terpeutico [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP como sistema de generador in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Pedraza L, M; Piedras R, J [Instituto Nacional de Ciencias Medicas y Nutricion, Salvador Zubiran. Vasco. de Quiroga 15, 14000 Mexico D.F. (Mexico); Ferro F, G; Morales R, P [ININ, Km. 36.5 Carretera Mexico-Toluca, Ocoyoacac, 52045 Estado de Mexico (Mexico); Murphy S, E [Hospital Santaelena, Mexico D.F. (Mexico); Hernandez O, O [Escuela Superior de Fisica y Matematicas, IPN, Mexico D.F. (Mexico)

    2005-07-01

    In patients with leukemias and multiple myeloma, the cure can be obtained to inclination of a bone marrow transplant (m.o.), for that which one is used a combination of external radiotherapy and chemotherapy with the consequent toxicity to healthy organs. The complex [{sup 166}Dy]Dy/{sup 166}Ho-ethylenediaminetetramethylenephosphonate ([{sup 166}Dy]Dy/{sup 166}Ho-EDTMP) it forms a generator system in vivo stable with bony selective likeness in mice therefore, this it could work as a therapeutic radiopharmaceutical for bone marrow ablation. The objective of this original work was to determine the genotoxic and cytotoxic damage produced by the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP like a generator system in vivo by means of the reticulocytes reduction (RET) and micronucleus elevation in reticulocytes (RET-MN) in peripheral blood and to evaluate its myeloablative potential for histopathologic studies. It was irradiated {sup 166}Dy{sub 2}O{sub 3} enriched and it was add in form {sup 166}DyCI{sub 3} to the EDTMP in a softening media of phosphates (pH 8), the optimal molar relationship {sup 166}Dy: EDTMP was 1.7:1 and the radiochemical purity was evaluated by ITLC. The Dy:EDTMP complexes, non radioactive, its were prepared in the same way with non irradiated dysprosium oxide. A group of BALB/c mice was injected intraperitoneally with the radiopharmaceutical and two groups of control mice were injected with the non radioactive complex and with sodium chloride 0.9% respectively. Before injecting each one of the solutions it was take a basal sample of peripheral blood of the mouse tail and each 48 h post-injection during 12 d. The animals were sacrificed to obtain the organs of interest and to determine the radioactivity in each one. The femur was used for the histopathologic studies. The quantification of the frequency of RET and RET-MN was carried out by flow cytometry of the sanguine samples and the Monte Carlo code MCNP4B for the dosimetry calculations was used. The

  8. Synthesis and ultrasonic characterisation of vitreous holmium phosphates

    International Nuclear Information System (INIS)

    Senin Hassan; Sidek Hj, Abdul Aziz; Abdul Halim Shaari

    1996-01-01

    The ultrasonic properties of holmium metaphosphate glasses (Ho sub 2 O sub 3) sub x (P sub 2 O sub 5) sub 1-x, with the mole fraction of x of holmium oxide equal to 0.208, 0.22 and 0.231 respectively, have been determined from measurements of the effects of temperature and hydrostatic pressure on ultrasonic wave velocities. At temperature below about 100K, the ultrasonic wave velocity of this type of rare earth phosphate glasses become anomalously dependent upon temperature; a behaviour associated with the interaction between acoustic phonons and two level systems. The hydrostatic pressure derivatives (∂ C sup S sub IJ / ∂ P) sub p=0 of the elastic stiffnesses C sub IJ and also (∂ C sup S sub IJ / ∂ P) sub p=0 of the bulk modulus B sup S of these glasses are anomalously negative. Both longitudinal γ sub L and shear γ sub S acoustic mode Gruneisen parameters are small and negative : the application of pressure softens the long-wavelength acoustic phonon mode frequencies. The results confirmed that the holmium phosphate glasses show an extraordinary elastic behaviour under high pressures

  9. Genotoxic and cytotoxic damage by the therapeutic radiopharmaceutical [166Dy]Dy/166Ho-EDTMP as in vivo generator system

    International Nuclear Information System (INIS)

    Pedraza L, M.; Piedras R, J.; Ferro F, G.; Morales R, P.; Murphy S, E.; Hernandez O, O.

    2005-01-01

    In patients with leukemias and multiple myeloma, the cure can be obtained to inclination of a bone marrow transplant (m.o.), for that which one is used a combination of external radiotherapy and chemotherapy with the consequent toxicity to healthy organs. The complex [ 166 Dy]Dy/ 166 Ho-ethylenediaminetetramethylenephosphonate ([ 166 Dy]Dy/ 166 Ho-EDTMP) it forms a generator system in vivo stable with bony selective likeness in mice therefore, this it could work as a therapeutic radiopharmaceutical for bone marrow ablation. The objective of this original work was to determine the genotoxic and cytotoxic damage produced by the [ 166 Dy]Dy/ 166 Ho-EDTMP like a generator system in vivo by means of the reticulocytes reduction (RET) and micronucleus elevation in reticulocytes (RET-MN) in peripheral blood and to evaluate its myeloablative potential for histopathologic studies. It was irradiated 166 Dy 2 O 3 enriched and it was add in form 166 DyCI 3 to the EDTMP in a softening media of phosphates (pH 8), the optimal molar relationship 166 Dy: EDTMP was 1.7:1 and the radiochemical purity was evaluated by ITLC. The Dy:EDTMP complexes, non radioactive, its were prepared in the same way with non irradiated dysprosium oxide. A group of BALB/c mice was injected intraperitoneally with the radiopharmaceutical and two groups of control mice were injected with the non radioactive complex and with sodium chloride 0.9% respectively. Before injecting each one of the solutions it was take a basal sample of peripheral blood of the mouse tail and each 48 h post-injection during 12 d. The animals were sacrificed to obtain the organs of interest and to determine the radioactivity in each one. The femur was used for the histopathologic studies. The quantification of the frequency of RET and RET-MN was carried out by flow cytometry of the sanguine samples and the Monte Carlo code MCNP4B for the dosimetry calculations was used. The radiochemical purity was 99% and in average the specific

  10. Holmium laser enucleation for prostate adenoma greater than 100 gm.: comparison to open prostatectomy.

    Science.gov (United States)

    Moody, J A; Lingeman, J E

    2001-02-01

    Options for treatment of large (greater than 100 gm.) prostatic adenomas have until now been limited to open surgery or transurethral resection by skilled resectionists. Considerable blood loss, morbidity, extended hospital stay and prolonged recovery occur with open surgery for large prostatic adenomas. Endoscopic surgery for benign prostatic hyperplasia has evolved during the last decade to offer the patient and surgeon significant advantages of transurethral removal of prostatic adenomas. Holmium laser enucleation of the prostate with transurethral tissue morcellation provides significant reductions in morbidity, bleeding and hospital stay for patients with large prostate adenomas. A retrospective review of data on 10 cases of holmium laser enucleation and 10 open prostatectomies for greater than 100 gm. prostatic adenomas was performed from 1998 to 1999 at our institution. Patient demographics, indication for surgery, preoperative and postoperative American Urological Association (AUA) symptom scores, operating time, serum hemoglobin, resected prostatic weight, pathological diagnosis, length of stay and complications were compared. Patient age, indications for surgery (retention, failed medical therapy, high post-void residual, bladder calculi, bladder diverticula and azotemia) and preoperative AUA symptom scores were similar in both groups. Postoperative AUA symptom scores were significantly decreased (p gm., p = 0.0003). Resected weight was greater in the holmium laser enucleation group (151 versus 106 gm., p = 0.07). Length of stay was significantly shorter in the holmium laser enucleation group (2.1 versus 6.1 days, p <0.001). Complications in the holmium laser enucleation group included stress urinary incontinence in 4 cases, prostatic perforation in 1 and urinary retention in 1. No patient treated with holmium laser enucleation was discharged home with an indwelling catheter. Complications in the open prostatectomy group included bladder neck contractures

  11. Acute and chronic response of meniscal fibrocartilage to holmium:YAG laser irradiation

    Science.gov (United States)

    Horan, Patrick J.; Popovic, Neven A.; Islinger, Richard B.; Kuklo, Timothy R.; Dick, Edward J.

    1997-05-01

    The acute and chronic (10 week) histological effects of the holmium:YAG laser during partial meniscectomy in an in vivo rabbit model were investigated. Twenty-four adult male New Zealand rabbits underwent bilateral parapatellar medial knee arthrotomies. In the right knee, a partial medial meniscectomy was done through the avascular zone using a standard surgical blade. In the left knee, an anatomically similar partial medial meniscectomy was performed using a Ho:YAG laser (Coherent, USA). This study indicates that the laser creates two zones of damage in the meniscal fibrocartilage and that the zone of thermal change may act as a barrier to healing. The zone of thermal change which is eventually debrided was thought at the time of surgery to be viable. In the laser cut menisci, the synovium appears to have greater inflammation early and to be equivalent with the scalpel cut after three weeks. At all time periods there appeared more cellular damage in the laser specimens.

  12. Acupoint Massage in Relieving Pain after Ureteroscopic Holmium Laser Lithotripsy

    Institute of Scientific and Technical Information of China (English)

    Xia Wei-qin

    2014-01-01

    Objective: To observe the effect of acupoint massage in relieving pain after ureteroscopic holmium laser lithotripsy. Methods: Ninety-two patients undergone ureteroscopic holmium laser lithotripsy were enrolled and randomized into a treatment group and a control group, 46 in each group. Patients in the control group were given regular nursing care, while patients in the treatment group were intervened by acupoint massage in addition to the regular nursing care. The pain was evaluated by visual analogue scale (VAS) at 6 h, 12 h, and 24 h after operation, and compared between the two groups. Results:There was no significant difference in comparing the VAS score at 6 h after operation between the two groups (P>0.05). The VAS scores in the treatment group at 12 h and 24 h after operation were significantly lower than those in the control group (both P Conclusion: Acupoint massage can effectively relieve the pain after ureteroscopic holmium laser lithotripsy, reduce the use of analgesics, and promote the recovery.

  13. Holmium:YAG laser effects on articular cartilage metabolism: in vitro

    Science.gov (United States)

    Smith, R. Lane; Montgomery, L.; Fanton, G.; Dillingham, M.; Schurman, D. J.

    1994-09-01

    We report effects of applying variable doses of Holmium:YAG laser energy to bovine articular cartilage in vitro. The response of the cartilage to the Holmium:YAG laser energy was determined by quantification of cell proliferation and extracellular matrix glycosaminoglycan synthesis. This study demonstrates that articular cartilage cell metabolism was maintained at a normal level following treatment of cartilage at a dose of 0.6 joules/pulse. The laser energy was applied at 10 Hz for 10 seconds at 1 mm distance from the cartilage. Under these conditions and at a dose of 0.6 joules/pulse, the total energy density was calculated to be 240 joules/cm2, assuming minimal loss of energy due to water absorption. Energy levels grater than 0.8 joules/pulse corresponding to calculated energy densities greater than 320 joules/cm2 proved harmful to cartilage. Our data demonstrate that low levels of Holmium:YAG laser energy can be applied to articular cartilage under conditions that maintain and/or stimulate cell metabolism.

  14. Tube closure device, especially for sample irradiation

    International Nuclear Information System (INIS)

    Klahn, F.C.; Nolan, J.H.; Wills, C.

    1979-01-01

    Device for closing the outlet of a bore and temporarily locking components in this bore. Specifically, it concerns a device for closing a tube containing a set of samples for monitoring irradiation in a nuclear reactor [fr

  15. Metrological traceability of holmium oxide solution

    Science.gov (United States)

    Gonçalves, D. E. F.; Gomes, J. F. S.; Alvarenga, A. P. D.; Borges, P. P.; Araujo, T. O.

    2018-03-01

    Holmium oxide solution was prepared as a candidate of certified reference material for spectrophotometer wavelength scale calibration. Here is presented the necessary steps for evaluation of the uncertainty and the establishment of metrological traceability for the production of this material. Preliminary results from the first produced batch are shown.

  16. Wound repair in rat urinary bladder following electrocautery or holmium laser incision

    Science.gov (United States)

    Venzi, Giordano; Schmidlin, Franz R.; Gabbiani, Giulio; Delacretaz, Guy P.; Pittet, Brigitte; Leisinger, Hans-Juerg; Iselin, Christoph E.

    1999-06-01

    Woundhealing is a complex phenomenon which varies according the type of tissue but is also depending from the type of tissue injury. Electrocautery mainly induces coagulation necrosis while thermal damages induced by the Holmium laser primarily lead to tissue vaporization which may induce less tissue injury. The aim of this study was to evaluate the healing process of the Holmium laser induced lesions compared to electrocautery induced lesions in urothelial tissue by assessing the inflammatory response and myofibroblast behavior in sequential healing phases. A surgical wound was created in the urinary rat bladder of 32 rats either by electrocautery or by laser (N=16). The inflammatory response, the total lesion depth and the myofibroblast activity during woundhealing was then analyzed on a qualitative basis on days 0/2/4/8. The overall inflammatory response was comparable in both groups up to days two and four. However, at day eight less cellular inflammatory reaction and less myofibroblast activity was found in the specimen of lesions created by the Holmium laser. These results suggest that wound repair may be a less invasive process after Holmium laser than electrocautery.

  17. Proton irradiation of liquid crystal based adaptive optical devices

    International Nuclear Information System (INIS)

    Buis, E.J.; Berkhout, G.C.G.; Love, G.D.; Kirby, A.K.; Taylor, J.M.; Hannemann, S.; Collon, M.J.

    2012-01-01

    To assess its radiation hardness, a liquid crystal based adaptive optical element has been irradiated using a 60 MeV proton beam. The device with the functionality of an optical beam steerer was characterised before, during and after the irradiation. A systematic set of measurements on the transmission and beam deflection angles was carried out. The measurements showed that the transmission decreased only marginally and that its optical performance degraded only after a very high proton fluence (10 10 p/cm 2 ). The device showed complete annealing in the functionality as a beam steerer, which leads to the conclusion that the liquid crystal technology for optical devices is not vulnerable to proton irradiation as expected in space.

  18. Proton irradiation of liquid crystal based adaptive optical devices

    Energy Technology Data Exchange (ETDEWEB)

    Buis, E.J., E-mail: ernst-jan.buis@tno.nl [cosine Science and Computing BV, Niels Bohrweg 11, 2333 CA Leiden (Netherlands); Berkhout, G.C.G. [cosine Science and Computing BV, Niels Bohrweg 11, 2333 CA Leiden (Netherlands); Huygens Laboratory, Leiden University, P.O. Box 9504, 2300 RA Leiden (Netherlands); Love, G.D.; Kirby, A.K.; Taylor, J.M. [Department of Physics, Durham University, South Road, Durham DH1 3LE (United Kingdom); Hannemann, S.; Collon, M.J. [cosine Research BV, Niels Bohrweg 11, 2333 CA Leiden (Netherlands)

    2012-01-01

    To assess its radiation hardness, a liquid crystal based adaptive optical element has been irradiated using a 60 MeV proton beam. The device with the functionality of an optical beam steerer was characterised before, during and after the irradiation. A systematic set of measurements on the transmission and beam deflection angles was carried out. The measurements showed that the transmission decreased only marginally and that its optical performance degraded only after a very high proton fluence (10{sup 10}p/cm{sup 2}). The device showed complete annealing in the functionality as a beam steerer, which leads to the conclusion that the liquid crystal technology for optical devices is not vulnerable to proton irradiation as expected in space.

  19. A device for external γ-irradiation of experimental animals

    International Nuclear Information System (INIS)

    Ivanitskaya, N.F.; Talakin, Yu.N.; Lekakh, V.A.

    1992-01-01

    A device was developed for external gamma-irradiation of experimental animals including a radiation source, a device for fixation of the total animal or a segment of its body in the focus of irradiation, and a shilding screen. To widen the sphere of this device application by making possible a simultaneous radiation exposure of a group of animals under various radiation schedules, the device involves two discs with a common axis. The lower disc is provided with an electric drive and containers with animals are placed on it, and the upper disc is for the shielding screen. The device is supplied with an operation block

  20. Development of cutting device for irradiated fuel rod

    International Nuclear Information System (INIS)

    Lee, E. P.; Jun, Y. B.; Hong, K. P.; Min, D. K.; Lee, H. K.; Su, H. S.; Kim, K. S.; Kwon, H. M.; Joo, Y. S.; Yoo, K. S.; Joo, J. S.; Kim, E. K.

    2004-01-01

    Post Irradiation Examination(PIE) on irradiated fuel rods is essential for the evaluation of integrity and irradiation performance of fuel rods of commercial reactor fuel. For PIE, fuel rods should be cut very precisely. The cutting positions selected from NDT data are very important for further destructive examination and analysis. A fuel rod cutting device was developed witch can cut fuel rods longitudinal very precisely and can also cut the fuels into the same length rod cuts repeatedly. It is also easy to remove the fuel cutting powder after cutting works and it can extend the life time of cutting device and lower the contamination level of hot cell

  1. Development of Therapeutic Modality of Esophageal Cancer Using Ho-166 Stent

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Doo; Park, Kwang Kyun; Lee, Min Geol [Yonsei University Medical College, Seoul (Korea, Republic of); Park, Kyung Bae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-09-01

    The prognosis of esophageal cancer is poor due absence of serosa which prevent local invasion to the surrounding organs such as aorta, mediastinum, trachea, and bronchi. We developed a Ho-166 Coated Radioactive Self-Expandable Metallic Stent which is a new herapeutic device in the treatment of esophageal cancer and underwent an animal experiment in mongrel dogs. We observed mucosal destruction by 4-6 mCi of Ho-166 without serious complications such as perforation of esophageal wall. Therefore, Ho-166 coated self-expandable stent appears to be an effective therapeutic device in the palliative treatment of esophageal cancer. 17 refs., 4 figs. (author)

  2. The upgraded control and instrumentation system of C5 irradiation device

    International Nuclear Information System (INIS)

    Iordache, A.; Ancuta, M.; Gruia, L.; Pulpa, A.; Salistean, E.; Gusescu, G.

    2013-01-01

    C5 capsule is an irradiation device of TRIGA SSR, which is designed for irradiation of structural materials in an inert environment for mechanical behavior characterization and the material microstructure evolution during irradiation. The paper presents the upgraded control and instrumentation system of the C5 irradiation device which was designed and manufactured to enhance the performance of this system for better surveillance and processing the acquired experimental data. (authors)

  3. Proton irradiation effects on gallium nitride-based devices

    Science.gov (United States)

    Karmarkar, Aditya P.

    Proton radiation effects on state-of-the-art gallium nitride-based devices were studied using Schottky diodes and high electron-mobility transistors. The device degradation was studied over a wide range of proton fluences. This study allowed for a correlation between proton irradiation effects between different types of devices and enhanced the understanding of the mechanisms responsible for radiation damage in GaN-based devices. Proton irradiation causes reduced carrier concentration and increased series resistance and ideality factor in Schottky diodes. 1.0-MeV protons cause greater degradation than 1.8-MeV protons because of their higher non-ionizing energy loss. The displacement damage in Schottky diodes recovers during annealing. High electron-mobility transistors exhibit extremely high radiation tolerance, continuing to perform up to a fluence of ˜1014 cm-2 of 1.8-MeV protons. Proton irradiation creates defect complexes in the thin-film structure. Decreased sheet carrier mobility due to increased carrier scattering and decreased sheet carrier density due to carrier removal by the defect centers are the primary damage mechanisms. Interface disorder at either the Schottky or the Ohmic contact plays a relatively unimportant part in overall device degradation in both Schottky diodes and high electron-mobility transistors.

  4. Experimental and clinical studies on the intraarterial injection of holmium-166 chitosan complex in the treatment of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Lee, Jong Tae; Kim, Eun Kyung; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Doo; Yoo, Hyung Sik; Yoo, Nae Choon; Park, Kyung Bae

    2001-01-01

    The purposes of this study were to evaluate the biodistribution and effect of Ho-166 radionuclide by intra-arterial injection of the Ho-166 chitosan complex in dogs and to assess the clinical efficacy and side effects of this complex in the treatment of hepatocellular carcinoma (HCC). In an experimental study, 20 mCi of Ho-166 chitosan complex was injected into the left hepatic artery of six adult dogs. The distribution of radioactivity in each organ was calculated using a gamma camera scan at regular intervals. A beta ray radioactivity count (cpm) of blood and urine was performed periodically, and hematologic and hepatic function were regularly assessed. At 4, 8 and 12 weeks after intra-arterial injection, bone marrow and liver were pathologically evaluated. Twenty-five patients with a single, nodular HCC mass 3-9 cm in diameter were treated by intra-arterial injection of Ho-166 chitosan complex, and immediately after the procedure a gamma camera scan was obtained. A beta ray radioactivity count(CPM) of blood was performed periodically, hematologic and hepatic function were regularly evaluated, and CT scans and angiograms were obtained 3 months after the procedure. On the basis of the CT and angiographic findings, the treatment effects were classified as complete (CR), partial (PR) or non-response(NR). In the animal study, blood radioactivity peaked immediately in each organ per whole body was 25% in the left lobe of the liver, 7% in the right lobe, 3% in the lung, 1.4-3% in the bladder, and 2% in bone. WBC and platelet counts declined maximally at 3-4 weeks and recovered at 12 weeks the cellularity of bone marrow was 25% at 4 weeks and 55% at 12 weeks, findings which correlated well with the observed hematologic changes. In the clinical study of 25 HCC patients, CR was achieved in 17 (68%) cases, PR in 5 (20%) and NR in 3 (12%). At gamma camera imaging immediately after treatment, tumor radioactivity was localized in 76% of cases. In six cases (24%) WBC and

  5. Chilean experience in production of therapeutic radiopharmaceuticals labelled with 153Sm and 166Ho

    International Nuclear Information System (INIS)

    Chandia, M.; Gil, M.G.; Tomicic, M.; Araya, G.; Olea, E.; Chong, G.

    1998-01-01

    153 Samarium ( 153 Sm) and 166 Holmium ( 166 Ho) were produced at the Nuclear Center of La Reina Research Reactor, Chilean Nuclear Energy Commission. 153 Sm-EDTMP (Ethylenediaminetetramethylene Phosphonate) used for clinical trial of therapy for painful skeletal metastases and labeled particles such as 166 Ho-FHMA (ferric hydroxide macroagregattes) and 153 Sm-HAP (hydroxiapatite particles) used for radiation synevectomy, were labeled. Radionuclide purity of both radionuclides was analyzed by gamma spectrometry using a multichannel gamma spectrometer. Radiochemical labeled reaction parameters of 153 Sm-EDTMP such as: Sm/EDTMP molar ratio, 153 Sm specific activity, labeled pH and temperature, were determined in order to get high radiolabeling yields. Radiochemical Quality Controls of 153 Sm-EDTMP using different chromatographic systems were carried out in order to determine labeling yields. Bodistribution studies were achieved in mice by dissection of animals and by autoradiography of histological slices in rats, after 2h post injection. 153 Sm-HAP and 166 Ho-FHMA labeled particles were prepared using the methods described. Radiochemical purity, in case of radiolabeled particles was carried out by centrifugation, measuring activity in the supernatant and in particles pellet. Physical parameters, such as particle size and range of the radiopharmaceuticals based on particles labeling were evaluated in order to determine the ideal conditions to obtain particles size range between 10 - 40μ. In vitro labeling stability for over seven days and wash out activity by incubation in human synovial fluid after 6 and 24h post labeling, was also studied. 153 Sm-EDTMP was easily labeled with a Radiochemical purity over 99.5% and stable for over 7 days. Biodistribution studies in mice give more than 50% of ID uptake in bone and less than 0,1% in liver this was correlated by autoradiographic image. 153 Sm-HAP and 166 Ho-FHMA were also labeling obtaining radiochemical purity over 95

  6. U-turn type continuous irradiation method and device for radiation-irradiated capsule

    International Nuclear Information System (INIS)

    Kikuchi, Takayuki.

    1997-01-01

    A capsule to be irradiated is moved while being rotated in one of conveying shafts disposed in a reactor to conduct irradiation treatment. Then, the irradiated capsule is made U-turn in the reactor, inserted to the other conveying shaft and moved while being rotated to conduct irradiation treatment again, and then transported out of the reactor. The device comprises a rotational conveying shaft for moving the irradiated capsule while rotating it, a conveying gear for U-turning the irradiated capsule in the reactor and inserting it to the conveying shaft and a driving mechanism for synchronously rotating the conveying gear relative to the conveying shaft at a constant ratio. Mechanical time loss and manual operation time loss can be reduced upon loading and taking up of the irradiated capsule. Then, the amount of irradiation treatment per unit time is increased, and an optional neutron irradiation amount can be obtained thereby enabling to reduce operator's radiation exposure. (N.H.)

  7. Thermal Response to High-Power Holmium Laser Lithotripsy.

    Science.gov (United States)

    Aldoukhi, Ali H; Ghani, Khurshid R; Hall, Timothy L; Roberts, William W

    2017-12-01

    The aim of this study was to investigate "caliceal" fluid temperature changes during holmium laser activation/lithotripsy using settings up to 40 W power output with different irrigation flow rates. The experimental system consisted of a glass test tube (diameter 10 mm/length 75 mm) filled with deionized water, to mimic a calix. Real-time temperature was recorded using a thermocouple (Physitemp, NJ) positioned 5 mm from the bottom of the tube. A 200 μm laser fiber (Flexiva; Boston Scientific, MA) was introduced through the working channel of a disposable ureteroscope (LithoVue; Boston Scientific) and the laser fiber tip was positioned 15 mm above the bottom of the test tube. Deionized water irrigation (room temperature) through the working channel of the ureteroscope was delivered at flow rates of 0, 7-8, 14-15, and 38-40 mL/minute. A 120-W holmium laser (pulse 120; Lumenis, CA) was used. The following settings were explored: 0.5 J × 10 Hz, 1.0 J × 10 Hz, 0.5 J × 20 Hz, 1.0 J × 20 Hz, 0.5 J × 40 Hz, 1.0 J × 40 Hz, and 0.5 J × 80 Hz. During each experiment, the laser was activated continuously for 60 seconds. Temperature increased with increasing laser power output and decreasing irrigation flow rate. The highest temperature, 70.3°C (standard deviation 2.7), occurred with laser setting of 1.0 J × 40 Hz and no irrigation after 60 seconds of continuous laser firing. None of the tested laser settings and irrigation parameters produced temperature exceeding 51°C when activated for only 10 seconds of continuous laser firing. High-power holmium settings fired in long bursts with low irrigation flow rates can generate high fluid temperatures in a laboratory "caliceal" model. Awareness of this risk allows urologist to implement a variety of techniques (higher irrigation flow rates, intermittent laser activation, and potentially cooled irrigation fluid) to control and mitigate thermal

  8. Irradiation devices at the upgraded research reactor BER II

    International Nuclear Information System (INIS)

    Gawlik, D.; Robertson, T.

    1992-06-01

    An overview is given of those properties of the BER II research reactor which are important for carrying out irradiation experiments. The subsequent section describes the irradiation devices currently installed in the reactor, or which are under construction, and some of the experiments which can be conducted using them. The field of application of these experiments extends from the study of the metabolism of trace elements in man, employing a highly sensitive element analysis, via radiation damage of high-tech materials, to the identification of paintings of the old masters. The report concludes with a review of the technical details of the irradiation devices, giving information of interest for potential users. (orig.)

  9. Cytotoxic and genotoxic effect of the [166Dy]Dy/166Ho-EDTMP in vivo generator system in mice

    International Nuclear Information System (INIS)

    Pedraza-Lopez, Martha; Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Morales-Ramirez, Pedro; Piedras-Ross, Josefa; Murphy-Stack, Eduardo; Hernandez-Oviedo, Omar

    2004-01-01

    Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. [ 166 Dy]Dy/ 166 Ho-ethylenediaminetetramethylene phosphonate (EDTMP) forms a stable in vivo generator system with selective skeletal uptake in mice; therefore, it could work as a potential and improved agent for marrow ablation. Induced bone marrow cytotoxicity and genotoxicity are determined by the reduction of reticulocytes (RET) and elevation of micronucleated reticulocyte (MN-RET) in peripheral blood and ablation by bone marrow histological studies. The aim of this study was to determine the bone marrow cytotoxic and genotoxic effect of the [ 166 Dy]Dy/ 166 Ho-EDTMP in vivo generator system in mice and to evaluate by histopathology its myeloablative potential. Enriched 166 Dy 2 O 3 was irradiated and [ 166 Dy]DyCl 3 was added to EDTMP in phosphate buffer (pH 8.0) in a molar ratio of 1:1.75. QC was determined by TLC. Dy-EDTMP complex was prepared the same way with nonirradiated dysprosium oxide. A group of BALB/c mice were intraperitoneally injected with the radiopharmaceutical and two groups of control animals were injected with the cold complex and with 0.9% sodium chloride, respectively. A blood sample was taken at the beginning of the experiments and every 48 h for 12 days postinjection. The animals were sacrificed, organs of interest taken out and the radioactivity determined. The femur was used for histological studies. Flow cytometry analysis was used to quantify the frequency of RET and MN-RET in the blood samples. The MCNP4B Monte Carlo computer code was used for dosimetry calculations. Radiochemical purity was 99% and the mean specific activity was 1.3 MBq/mg. The RET and MN-RET frequency were statistically different in the treatment at the end of the 12-day period demonstrating cytotoxicity and genotoxicity induced by the in vivo generator system. The histology studies show that there was

  10. Comparison of ESWL and ureteroscopic holmium laser lithotripsy in management of ureteral stones.

    Science.gov (United States)

    Cui, Yon; Cao, Wenzhou; Shen, Hua; Xie, Jianjun; Adams, Tamara S; Zhang, Yuanyuan; Shao, Qiang

    2014-01-01

    There are many options for urologists to treat ureteral stones that range from 8 mm to 15 mm, including ESWL and ureteroscopic holmium laser lithotripsy. While both ESWL and ureteroscopy are effective and minimally invasive procedures, there is still controversy over which one is more suitable for ureteral stones. To perform a retrospective study to compare the efficiency, safety and complications using ESWL vs. ureteroscopic holmium laser lithotripsy in management of ureteral stones. Between October 2010 and October 2012, 160 patients who underwent ESWL or ureteroscopic holmium laser lithotripsy at Suzhou municipal hospital for a single radiopaque ureteral stone (the size 8-15 mm) were evaluated. All patients were followed up with ultrasonography for six months. Stone clearance rate, costs and complications were compared. Similarity in stone clearance rate and treatment time between the two procedures; overall procedural time, analgesia requirement and total cost were significantly different. Renal colic and gross hematuria were more frequent with ESWL while voiding symptoms were more frequent with ureteroscopy. Both procedures used for ureteral stones ranging from 8 to 15 mm were safe and minimally invasive. ESWL remains first line therapy for proximal ureteral stones while ureteroscopic holmium laser lithotripsy costs more. To determining which one is preferable depends on not only stone characteristics but also patient acceptance and cost-effectiveness ratio.

  11. Comparison of ESWL and ureteroscopic holmium laser lithotripsy in management of ureteral stones.

    Directory of Open Access Journals (Sweden)

    Yon Cui

    Full Text Available BACKGROUND: There are many options for urologists to treat ureteral stones that range from 8 mm to 15 mm, including ESWL and ureteroscopic holmium laser lithotripsy. While both ESWL and ureteroscopy are effective and minimally invasive procedures, there is still controversy over which one is more suitable for ureteral stones. OBJECTIVE: To perform a retrospective study to compare the efficiency, safety and complications using ESWL vs. ureteroscopic holmium laser lithotripsy in management of ureteral stones. METHODS: Between October 2010 and October 2012, 160 patients who underwent ESWL or ureteroscopic holmium laser lithotripsy at Suzhou municipal hospital for a single radiopaque ureteral stone (the size 8-15 mm were evaluated. All patients were followed up with ultrasonography for six months. Stone clearance rate, costs and complications were compared. RESULTS: Similarity in stone clearance rate and treatment time between the two procedures; overall procedural time, analgesia requirement and total cost were significantly different. Renal colic and gross hematuria were more frequent with ESWL while voiding symptoms were more frequent with ureteroscopy. Both procedures used for ureteral stones ranging from 8 to 15 mm were safe and minimally invasive. CONCLUSION: ESWL remains first line therapy for proximal ureteral stones while ureteroscopic holmium laser lithotripsy costs more. To determining which one is preferable depends on not only stone characteristics but also patient acceptance and cost-effectiveness ratio.

  12. Effect of silver nanoparticles on the dielectric properties of holmium doped silica glass

    International Nuclear Information System (INIS)

    Rejikumar, P.R.; Jyothy, P.V.; Mathew, Siby; Thomas, Vinoy; Unnikrishnan, N.V.

    2010-01-01

    The effect of silver nanoparticle co-doping on the dielectric properties of holmium doped silica glasses was studied. Silver nanoparticles of size between 20 and 22 nm were produced by the sol-gel technique. One of the samples showed an icosahedral morphology of the nanocrystal formed, along with spherical morphology. It was found that the tuning of the dielectric constant values could be accomplished by co-doping. The sample, with 1 wt% of Ho, had low dielectric constant values within the range 100 Hz-3 MHz due to the formation of quasi-molecular structures of holmium. This effect was evaded to some extent with silver co-doping as a result of the interdispersion of holmium complexes. Also it was found that the co-doping produced a higher dielectric loss which was calculated from the tan δ-log f graph. The Cole-Cole parameters and the Jonscher power law parameters were also calculated and are presented.

  13. Development of an irradiation device for electron beam wastewater treatment

    International Nuclear Information System (INIS)

    Rela, Paulo Roberto

    2003-01-01

    When domestic or industrial effluents with synthetic compounds are disposed without an adequate treatment, they impact negatively the environment with damages to aquatic life and for the human being. Both population and use of goods and services that contribute for the hazardous waste are growing. Hazardous regulations are becoming more restrictive and technologies, which do not destroy these products, are becoming less acceptable. The electron beam radiation process is an advanced oxidation process, that produces highly reactive radicals resulting in mineralization of the contaminant. In this work was developed an irradiation system in order to optimize the interaction of electron beam delivered from the accelerator with the processed effluent. It is composed by an irradiation device where the effluent presents to the electron beam in an up flow stream and a process control unit that uses the calorimetric principle. The developed irradiation device has a different configuration from the devices used by others researchers that are working with this technology. It was studied the technical and economic feasibility, comparing with the literature the results of the irradiation device demonstrated that it has a superior performance, becoming an process for use in disinfection and degradation of hazardous organic compounds of wastewater from domestic and industrial origin, contributing as an alternative technology for Sanitary Engineering. (author)

  14. [Comparison of validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy].

    Science.gov (United States)

    Bi, Sheng; Xia, Ming

    2015-08-11

    To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.

  15. Microspheres with Ultrahigh Holmium Content for Radioablation of Malignancies

    NARCIS (Netherlands)

    Bult, W.; Seevinck, P.R.; Krijger, G.C.; Visser, T.; Kroon-Batenburg, L.M.J.; Bakker, C.J.G.; Hennink, W.E.; van het Schip, A.D.; Nijsen, J.F.W.

    2009-01-01

    The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  16. Ureteroscopic holmium laser cutting for inadvertently sutured drainage tube (report of five cases).

    Science.gov (United States)

    Gao, Xu; Lu, Xin; Ren, Shancheng; Xu, Chuanliang; Sun, Yinghao

    2008-07-01

    The aim of this paper is to report a simple solution for inadvertently sutured drainage tube after urological surgery and discuss the different managements according to different types of this embarrassing complication. From September 2001 to January 2007, five inadvertently sutured drainage tubes were treated with ureteroscopic holmium laser cutting for the suture. All drainage tubes were removed after the operation without other complications. Holmium laser cutting via ureteroscope is a simple solution for the embarrassing problem of inadvertently sutured drainage tube. It can save the patient from undergoing another open surgery.

  17. Ethanolamine derivatives of dysprosium and holmium

    International Nuclear Information System (INIS)

    Gharia, K.S.; Singh, M.; Mathur, S.; Sankhla, B.S.

    1981-01-01

    The preparation and properties of dysprosium and holmium derivatives of mono-, di- and tri-ethanolamine derivatives are described. Compounds of general formulae: Ln(OPrsup(i)) 2 (mea), Ln(OPrsup(i))(mea) 2 , Ln(mea) 3 , Ln(OPrsup(i))(dea), Ln 2 (dea) 3 , Ln(dea)(deaH) and Ln(tea) (where Ln = Dy or Ho and mea, dea and tea are the anions of respective ethanolamine) were obtained and characterized by elemental analysis and IR spectra. (author)

  18. Chitosan microspheres loaded with holmium-165 produced by spray dryer for liver cancer therapy: preliminary experiments

    International Nuclear Information System (INIS)

    Miyamoto, Douglas Massao; Pires, Geovanna; Lira, Raphael A. de; Melo, Vitor H.S.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de; Osso Junior, Joao Alberto

    2011-01-01

    Chitosan is a biopolymer of 2-deoxy-2-amino-D-glucose that is obtained by deacetylation of chitin. It's biocompatible, biodegradable, non toxic and has antitumor activity. Chitosan has many applications, such as their microparticles that can be used to treat prostate cancer, rheumatoid arthritis, and for liver tumor brachytherapy treatment. Our group is developing different biodegradable polymer-based microspheres loaded with holmium-165 for this purpose. The Chitosan microspheres were produced loaded with holmium (III) chloride, and not loaded with it, by Mini Spray Dryer procedure. The microspheres were evaluated by scanning electron microscopy, energy dispersive spectroscopy (EDS), confocal laser scanning microscopy, thermogravimetric analysis, particle size, and X-ray diffraction. The EDS analysis confirmed the holmium chloride presence into the prepared chitosan microparticles. (author)

  19. Chitosan microspheres loaded with holmium-165 produced by spray dryer for liver cancer therapy: preliminary experiments

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Douglas Massao; Pires, Geovanna; Lira, Raphael A. de; Melo, Vitor H.S.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de, E-mail: douglas.miyamoto@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia

    2011-07-01

    Chitosan is a biopolymer of 2-deoxy-2-amino-D-glucose that is obtained by deacetylation of chitin. It's biocompatible, biodegradable, non toxic and has antitumor activity. Chitosan has many applications, such as their microparticles that can be used to treat prostate cancer, rheumatoid arthritis, and for liver tumor brachytherapy treatment. Our group is developing different biodegradable polymer-based microspheres loaded with holmium-165 for this purpose. The Chitosan microspheres were produced loaded with holmium (III) chloride, and not loaded with it, by Mini Spray Dryer procedure. The microspheres were evaluated by scanning electron microscopy, energy dispersive spectroscopy (EDS), confocal laser scanning microscopy, thermogravimetric analysis, particle size, and X-ray diffraction. The EDS analysis confirmed the holmium chloride presence into the prepared chitosan microparticles. (author)

  20. Microspheres with ultrahigh holmium content for radioablation of malignancies

    NARCIS (Netherlands)

    Bult, W; Seevinck, P R; Krijger, G C; Visser, T; Kroon-Batenburg, L M J; Bakker, C J G; Hennink, W E; van het Schip, A D; Nijsen, J F W

    PURPOSE: The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  1. Microspheres with Ultrahigh Holmium Content for Radioablation of Malignancies

    NARCIS (Netherlands)

    Bult, W.; Seevinck, P.R.; Krijger, G.C.; Visser, T.; Kroon-Batenburg, L.M.J.; Bakker, C.J.G.; Hennink, W.E.; Van het Schip, A.D.; Nijsen, J.F.W.

    Purpose The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  2. The upgraded control and instrumentation system of C9 irradiation device

    International Nuclear Information System (INIS)

    Pulpa, A.; Parvu, C.; Valeca, S. C.; Ancuta, M.; Ana, E.

    2016-01-01

    C9 Capsule is an irradiation device of TRIGA SSR, which was designed for nuclear fuel cycling testing. It simulates the load follow-up by the power reactor, i.e. CANDU 700MW operating with variable load. The irradiation tests in the power cycling conditions were conceived for complete characterization of the fuel behaviour. The irradiation conditions are similar to those found in nuclear power plant when it is operated in load following mode. The power cycling tests are performed by using an under flux moving system. The paper presents the upgraded control and instrumentation system of the ''9C irradiation device, designed and manufactured in order to enhance the performance of this system for better surveillance and processing of the acquired experimental data. (authors)

  3. Production, Quality Control and Biological Evaluation of 166Ho-PDTMP as a Possible Bone Palliation Agent

    Directory of Open Access Journals (Sweden)

    Samaneh Zolghadri

    2013-05-01

    Full Text Available Objective(s:In this study, 166Ho-1,2-propylene di-amino tetra(methy1enephosphonicAcid (166Ho-PDTMP complex  was prepared as a bone palliation agent. Materials and Methods:The complex was successfully prepared using an in-house synthesized EDTMP ligand and 166HoCl3. Ho-166 chloride was obtained by thermal neutron irradiation (1 × 1013 n.cm-2.s-1 of natural Ho(NO33 samples  followed by radiolabeling and stability studies. Biodistribution in wild type rats was also peformed. Results: The complex was prepared with thespecific activity of 278 GBq/mg and high radiochemical purity (>99%, checked by ITLC. 166Ho-PDTMP complex was stabilized in the final preparation and in the presence of human serum (>90% up to 72 hr. The biodistribution of 166Ho-PDTMP in wild-type rats demonstrated significant bone uptake was up to 48 hr compared to 166HoCl3. Conclusion: The produced 166Ho-PDTMP properties suggest a possible new bone palliative therapeutic to overcome the metastatic bone pains.  

  4. Research of CITP-II tritium production irradiation device design

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yongjun; Mi Xiangmiao; Li Rundong; Liu Zhiyong

    2012-01-01

    As the core component of CITP-II, the online tritium production irradiation device is the pivotal equipment in the research on tritium production and release of tritium breeders. The design of CITP-II online tritium production irradiation device creatively makes replacing the breeders online come true; as tritium production capacity, the self-shielding factor of device, and neutron flux were studied. The influence of different load models and load thicknesses of breeders to tritium production capacity was calculated. The hydrodynamics parameters of device in solid-gas phase were computed. Thermal parameters, such as the heat power of breeders, hotspot, temperature grads distributions, utmost temperature, uneven factors, were analyzed. Creatively designed nonlinear electric heater equalized breeders' even heat power. The influence laws of the components, pressure of gap gas and carrier gas to the balance temperature were got. And the key thermal parameters were ascertained. The key thermal parameters and the changing laws were got and provide the basis for structural optimization and safety analysis. They can also be referenced for the study of breeders' tritium production and release. (authors)

  5. Holmium laser use in the treatment of selected dry eye syndrome complications

    Science.gov (United States)

    Kecik, Dariusz; Kecik, Tadeusz; Kasprzak, Jan; Kecik, Mariusz

    1996-03-01

    The authors present initial results of treatment selected complications of dry eye syndrome with holmium laser. The lacrimal puncta obliteration and coagulation of the corneal ulcer surface were done.

  6. Cytotoxic and genotoxic effect of the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system in mice

    Energy Technology Data Exchange (ETDEWEB)

    Pedraza-Lopez, Martha [Departamento de Medicina Nuclear, Instituto Nacional de Ciencias Medicas y Nutricion, Salvador Zubiran, Delegacion Tlalpan, Mexico DF 14000 (Mexico); Ferro-Flores, Guillermina [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca, Ocoyoacac, Estado de Mexico, CP 52045 (Mexico); Arteaga de Murphy, Consuelo [Departamento de Medicina Nuclear, Instituto Nacional de Ciencias Medicas y Nutricion, Salvador Zubiran, Delegacion Tlalpan, Mexico DF 14000 (Mexico)]. E-mail: consuelo_murphy@yahoo.com.mx; Morales-Ramirez, Pedro [Instituto Nacional de Investigaciones Nucleares, Carretera Mexico-Toluca, Ocoyoacac, Estado de Mexico, CP 52045 (Mexico); Piedras-Ross, Josefa [Departamento de Medicina Nuclear, Instituto Nacional de Ciencias Medicas y Nutricion, Salvador Zubiran, Delegacion Tlalpan, Mexico DF 14000 (Mexico); Murphy-Stack, Eduardo [Hospital Santaelena, Mexico DF (Mexico); Hernandez-Oviedo, Omar [Escuela Superior de Fisica y Matematicas, IPN, Mexico DF (Mexico)

    2004-11-01

    Multiple myeloma and other hematological malignancies have been treated by myeloablative radiotherapy/chemotherapy and subsequent stem cell transplantation. [{sup 166}Dy]Dy/{sup 166}Ho-ethylenediaminetetramethylene phosphonate (EDTMP) forms a stable in vivo generator system with selective skeletal uptake in mice; therefore, it could work as a potential and improved agent for marrow ablation. Induced bone marrow cytotoxicity and genotoxicity are determined by the reduction of reticulocytes (RET) and elevation of micronucleated reticulocyte (MN-RET) in peripheral blood and ablation by bone marrow histological studies. The aim of this study was to determine the bone marrow cytotoxic and genotoxic effect of the [{sup 166}Dy]Dy/{sup 166}Ho-EDTMP in vivo generator system in mice and to evaluate by histopathology its myeloablative potential. Enriched {sup 166}Dy{sub 2}O{sub 3} was irradiated and [{sup 166}Dy]DyCl{sub 3} was added to EDTMP in phosphate buffer (pH 8.0) in a molar ratio of 1:1.75. QC was determined by TLC. Dy-EDTMP complex was prepared the same way with nonirradiated dysprosium oxide. A group of BALB/c mice were intraperitoneally injected with the radiopharmaceutical and two groups of control animals were injected with the cold complex and with 0.9% sodium chloride, respectively. A blood sample was taken at the beginning of the experiments and every 48 h for 12 days postinjection. The animals were sacrificed, organs of interest taken out and the radioactivity determined. The femur was used for histological studies. Flow cytometry analysis was used to quantify the frequency of RET and MN-RET in the blood samples. The MCNP4B Monte Carlo computer code was used for dosimetry calculations. Radiochemical purity was 99% and the mean specific activity was 1.3 MBq/mg. The RET and MN-RET frequency were statistically different in the treatment at the end of the 12-day period demonstrating cytotoxicity and genotoxicity induced by the in vivo generator system. The

  7. Thermal design of an irradiation device with cobalt

    International Nuclear Information System (INIS)

    Parkansky, David; Halpert, Silvia G.; Vazquez, Luis A.

    1999-01-01

    The thermal behavior of a device to transport 60 Co rods has been calculated. The device has been designed to be also used to radio sterilize medical supplies and hospital wastes. The calculations show that, in normal conditions, the maximum temperature of the external surface of the device is 55 C and that of the shielding lead is 110 C. In fire conditions, without taking into account the radiation of heath to or from the combustion gases, the lead does not reach the melting point. If the gases are taken into account, only 6.3 % of the lead is melted down. The transport-irradiation device complies with the IAEA recommendations on the safe transport of radioactive material

  8. Holmium hafnate: An emerging electronic device material

    Science.gov (United States)

    Pavunny, Shojan P.; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Scott, James F.; Katiyar, Ram S.

    2015-03-01

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho2Hf2O7 (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ˜20 and very low dielectric loss of ˜0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap Eg of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices.

  9. 166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment

    International Nuclear Information System (INIS)

    Chandia, M.C.; Errazu, X.C.; Pinto, L.N.; Godoy, N.O.; Avila, M.J.; Mendoza, P.; Mendoza, J.; Jofre, J.; Sirraalta, P.

    2002-01-01

    Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate 166 Ho-Hydroxyapatite ( 166 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho 2 O 3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the 166 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and images from the inflamated articulation using 67 Ga citrate before and after 166 Ho-HA injection. Results: The radiochemical purity of the inoculated compound was greater than 98% as measured under sterility conditions. Clinically, an inflammation reduction (2 cm), appetite improvement and general well being was observed. The 166 Ho-HA distribution and localization was monitored using gamma camera images taken at 4 and 24 h. There was no evidence of extra articular leakage. From the 67 Ga citrate imaging, the acute group shows an overall improvement of well being corresponding to a lesser uptake at the inflamated articulation, regarding to the chronic group. The 166 Ho-HA double doses, compared to the single doses, suggest a reduced uptake of 67 Ga citrate at the inflamated tissue, meaning an increased therapeutic effect. Conclusions: 166 Ho-HA is useful as therapeutic agent for the symptomatic treatment of rheumatoid arthritis as shown by imaging and clinical examination

  10. 166 Ho-HA Evaluation as therapeutic agent for rheumatoid arthritis treatment

    International Nuclear Information System (INIS)

    Chandia, M; Errazu, X; Mendoza, P; Troncoso, F; Jofre, J; Sierralta, P

    2003-01-01

    Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This lead to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate 166 Ho-Hydroxyapatite ( 166 Ho-HA) as potential radiopharmaceutical for the syntomatic treatment of chronic and acute arthritis Materials and Methods: 166 Holmiun was produced by irradiation of Ho 2 O 3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthetized. Its labelling and quality controls follows the internationally accepted procedures. An antigen arthritis was induced to eight New Zealand rabbits with the 166 Ho-HA radiochemical being administred thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and images from the inflamated articulation using 67 Ga citrate before and after 166 Ho-HA injection. Results: The radiochemical purity of the innoculated compound was greater than 98% as measured under sterility conditions. Clinically, an inflamation reduction (2 cm), appetite improvement and general well being was observed. The 166 Ho-HA distribution and localization was monitored using gamma camera images taken at 4 and 24 h. There was no evidence of extraarticular leakage. From the 67 Ga citrate imaging, the acute group shows an overall improvement of well being corresponding to a lesser uptake at the inflamated articulation, regarding to the chronic group. The 166 Ho-HA double dosis, compared to the single dosis, suggest a reduced uptake of 67 Ga citrate at the inflamated tissue, meaning an increased therapeutic effect. Conclusions: 166 Ho-HA is usefull as therapeutic agent for the syntomatic treatment of rheumatoideal arthritis as shown by imaging and clinical examination (author)

  11. Development and evaluation of holmium doped phosphate glass microspheres for selective internal radiotherapy

    International Nuclear Information System (INIS)

    Barros Filho, Eraldo C.; Martinelli, Jose Roberto; Squair, Peterson L; Osso Junior, Joao A.; Sene, Frank Ferrer

    2013-01-01

    Selective Internal Radiotherapy is used to treat hepatocellular carcinoma. In this treatment 90 Y -doped aluminosilicate glass microspheres are introduced in the hepatic artery and they migrate to the liver near to the tumor where they are trapped in the arterioles. The radiation β- emitted by the decay of 90 Y annihilates the cancer cells. A macroaggregate of albumin containing technetium is previously used to monitor the lung shunt and to prevent the spreading of 90 Y during the treatment. In the present work, 165 Ho- doped phosphate glass microspheres were developed aiming that application. 165 Ho has high cross section for neutron capture (64 bars) and 166 Ho decays emitting β- radiation with appropriate energy for killing cancer cells, and gamma rays with low energy which can be used to obtain images of the microspheres location and to check possible occurrence of lung shunt. Holmium also is highly paramagnetic and can be used to obtain images whereby NMR. The glass matrix consists of (P 2 O 5 ) tetrahedrons and can be produced by a relatively lower melting temperature of chemical compounds. The 31 P decays by emitting β- radiation and contributes to the absorbed dose, helping to annihilate the cancer cells. The microspheres were produced by using two methods: the flame and the gravitation falling methods to obtain microspheres with appropriate properties. (author)

  12. Holmium hafnate: An emerging electronic device material

    International Nuclear Information System (INIS)

    Pavunny, Shojan P.; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Katiyar, Ram S.; Scott, James F.

    2015-01-01

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho 2 Hf 2 O 7 (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ∼20 and very low dielectric loss of ∼0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap E g of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices

  13. Holmium hafnate: An emerging electronic device material

    Energy Technology Data Exchange (ETDEWEB)

    Pavunny, Shojan P., E-mail: shojanpp@gmail.com, E-mail: rkatiyar@hpcf.upr.edu; Sharma, Yogesh; Kooriyattil, Sudheendran; Dugu, Sita; Katiyar, Rajesh K.; Katiyar, Ram S., E-mail: shojanpp@gmail.com, E-mail: rkatiyar@hpcf.upr.edu [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, P.O. Box 70377, San Juan, Puerto Rico 00936-8377 (United States); Scott, James F. [Department of Physics and Institute for Functional Nanomaterials, University of Puerto Rico, P.O. Box 70377, San Juan, Puerto Rico 00936-8377 (United States); Department of Physics, Cavendish Laboratory, University of Cambridge, Cambridge CB3 OHE (United Kingdom)

    2015-03-16

    We report structural, optical, charge transport, and temperature properties as well as the frequency dependence of the dielectric constant of Ho{sub 2}Hf{sub 2}O{sub 7} (HHO) which make this material desirable as an alternative high-k dielectric for future silicon technology devices. A high dielectric constant of ∼20 and very low dielectric loss of ∼0.1% are temperature and voltage independent at 100 kHz near ambient conditions. The Pt/HHO/Pt capacitor exhibits exceptionally low Schottky emission-based leakage currents. In combination with the large observed bandgap E{sub g} of 5.6 eV, determined by diffuse reflectance spectroscopy, our results reveal fundamental physics and materials science of the HHO metal oxide and its potential application as a high-k dielectric for the next generation of complementary metal-oxide-semiconductor devices.

  14. Development of heavy-ion irradiation technique for single-event in semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Norio; Akutsu, Takao; Matsuda, Sumio [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Naitoh, Ichiro; Itoh, Hisayoshi; Agematsu, Takashi; Kamiya, Tomihiro; Nashiyama, Isamu

    1997-03-01

    Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

  15. Irradiation technology Pt. 2. Research devices. Glossary on radiation technology. Besugarzastechnika 2. resz. Kiserleti berendezesek, sugartechnikai kislexikon

    Energy Technology Data Exchange (ETDEWEB)

    Foeldiak, G; Stenger, V

    1982-01-01

    It is a textbook and manual of a training course held at the Budapest Technical University for operators of irradiation devices. Calculation methods of radiation technology (estimation of activity variation, space dependence of dose rates, shielding, efficiency) are presented. Instructions for laboratory exercises (dose and dose rate measurements, sterilization by irradiation, handling of irradiation devices) involved in the course given. Two laboratory irradiation devices (RH-GAMMA-30, produced in the Soviet Union and the K-120-type semi-large scale device of the Isotope Institute of the Hungarian Academy of Sciences are described in detail. Handling instructions for the two devices and radiation protection regulations are given. A brief glossary in the field of radiation technology is added.

  16. Holmium-166m: multi-gamma standard to determine the activity of radionuclides in semiconductor detectors

    International Nuclear Information System (INIS)

    Bernardes, Estela Maria de Oliveira

    2001-01-01

    The efficiency and calibration curves as function of gamma-ray energy for a germanium detector are usually established by using many standard gamma ray sources of radionuclides decaying with few gamma rays or radionuclides having complex decay scheme, as 152 Eu or 133 Ba. But these radionuclides cannot be used alone, because they have a few gamma lines with high intensity and these lines have a irregular distribution in the energy spectrum. 166m Ho is found to be a convenient single source for such calibration, because it decays by β - with subsequent emission of about 40 strong and well distributed gamma lines between 80 and 1500 keV. Moreover, its long half - life (1200 years) and X-rays characteristics between 40 and 50 keV makes it a good standard for calibration of germanium detectors. However, it is necessary to know with accuracy and precision the gamma ray intensities of their main lines, due to the fact that literature has showed discrepant values. Then, a methodology to determine the emission probability of its main lines is proposed by means of combined use of gamma spectrometry and coincidence 4πβ -γ techniques. The experimental results show consistence to the others authors, with lower or compatible uncertainties. (author)

  17. {sup 166} Ho-HA Evaluation as therapeutic agent for rheumatoid arthritis treatment; Evaluacion de {sup 166}Ho-Ha como agente terapeutico en el tratamiento de la artritis reumatoidea

    Energy Technology Data Exchange (ETDEWEB)

    Chandia, M; Errazu, X [Comision Chilena de Energia Nuclear, Santiago (Chile); Mendoza, P [Departamento de Medicina Nuclear, Hospital Militar, Santiago (Chile); Troncoso, F [Comision Chilena de Energia Nuclear, Santiago (Chile); Jofre, J; Sierralta, P [Departamento de Medicina Nuclear, Hospital Militar, Santiago (Chile)

    2003-01-01

    Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This lead to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate {sup 166}Ho-Hydroxyapatite ({sup 166} Ho-HA) as potential radiopharmaceutical for the syntomatic treatment of chronic and acute arthritis Materials and Methods: {sup 166}Holmiun was produced by irradiation of Ho{sub 2}O{sub 3} at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthetized. Its labelling and quality controls follows the internationally accepted procedures. An antigen arthritis was induced to eight New Zealand rabbits with the {sup 166}Ho-HA radiochemical being administred thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and images from the inflamated articulation using {sup 67}Ga citrate before and after {sup 166} Ho-HA injection. Results: The radiochemical purity of the innoculated compound was greater than 98% as measured under sterility conditions. Clinically, an inflamation reduction (2 cm), appetite improvement and general well being was observed. The {sup 166} Ho-HA distribution and localization was monitored using gamma camera images taken at 4 and 24 h. There was no evidence of extraarticular leakage. From the {sup 67}Ga citrate imaging, the acute group shows an overall improvement of well being corresponding to a lesser uptake at the inflamated articulation, regarding to the chronic group. The {sup 166}Ho-HA double dosis, compared to the single dosis, suggest a reduced uptake of {sup 67}Ga citrate at the inflamated tissue, meaning an increased therapeutic effect. Conclusions: {sup 166} Ho-HA is usefull as therapeutic agent for the syntomatic treatment of rheumatoideal arthritis

  18. Device for taking gaseous samples from irradiated fuel elements

    International Nuclear Information System (INIS)

    Lengacker, B.

    1983-01-01

    The described device allows to take gaseous samples from irradiated fuel elements. It is connected with a gas analyzer and a pressure gage, so that in opening the fuel can the internal pressure can be determined

  19. The performance of the anthraquinone/p-Si and the pyridine/p-Si rectifying device under X-ray irradiation

    International Nuclear Information System (INIS)

    Şahin, Yılmaz; Aydoğan, Şakir; Ekinci, Duygu; Turut, Abdulmecit

    2016-01-01

    Some X-ray irradiation-induced electrical characteristics of the Au/anthraquinone/p-Si and the Au/pyridine/p-Si junction devices have been investigated. The experimental ideality factors increased for both devices with increasing irradiation dose from 25 Gy to 150 Gy. These values ranged from 1.10 to 1.52 for Au/anthraquinone/p-Si and from 1.46 to 1.77 for Au/pyridine/p-Si, respectively. Furthermore, the barrier height of Au/anthraquinone/p-Si increased with increasing irradiation dose from 0.75 to 0.91 eV, whereas it displayed about a constant value for Au/pyridine/p-Si. In addition, the series resistance of both devices increased with x-ray dose too. The increase in the series resistance with x-ray irradiation has been attributed to the decrease in the active dopant densities. It was seen that the ionization damage is effective on most of the junction characteristics. The leakage current of the Au/anthraquinone/p-Si device decreased with x-ray irradiation since the irradiation induced the formation of electron-hole pairs and hydroquinone structure, and thus some of them are trapped by the interface states. The degradation of the I-V curves of Au/pyridine/p-Si/Al device is attributed to the variation of the surface or interface states distribution for the devices. The reverse and forward bias currents relatively increased after x-ray irradiation because of the decrease in bulk lifetime. In addition, ATR-FTIR spectra of anthraquinone and pyridine films showed that pyridine is more stable than anthraquinone under x-ray irradiation. - Highlights: • Two junction devices based on organic materials were fabricated. • The effect of the x-ray irradiation on devices were examined. • Both devices showed x-irradiation-dependence.

  20. The performance of the anthraquinone/p-Si and the pyridine/p-Si rectifying device under X-ray irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Şahin, Yılmaz [Department of Physics, Faculty of Sciences, University of Atatürk, 25240 Erzurum (Turkey); Aydoğan, Şakir, E-mail: saydogan@atauni.edu.tr [Department of Physics, Faculty of Sciences, University of Atatürk, 25240 Erzurum (Turkey); Ekinci, Duygu [Department of Chemistry, Faculty of Sciences, University of Atatürk, 25240 Erzurum (Turkey); Turut, Abdulmecit [Department of Engineering Physics, Faculty of Sciences, Istanbul Medeniyet University (Turkey)

    2016-11-01

    Some X-ray irradiation-induced electrical characteristics of the Au/anthraquinone/p-Si and the Au/pyridine/p-Si junction devices have been investigated. The experimental ideality factors increased for both devices with increasing irradiation dose from 25 Gy to 150 Gy. These values ranged from 1.10 to 1.52 for Au/anthraquinone/p-Si and from 1.46 to 1.77 for Au/pyridine/p-Si, respectively. Furthermore, the barrier height of Au/anthraquinone/p-Si increased with increasing irradiation dose from 0.75 to 0.91 eV, whereas it displayed about a constant value for Au/pyridine/p-Si. In addition, the series resistance of both devices increased with x-ray dose too. The increase in the series resistance with x-ray irradiation has been attributed to the decrease in the active dopant densities. It was seen that the ionization damage is effective on most of the junction characteristics. The leakage current of the Au/anthraquinone/p-Si device decreased with x-ray irradiation since the irradiation induced the formation of electron-hole pairs and hydroquinone structure, and thus some of them are trapped by the interface states. The degradation of the I-V curves of Au/pyridine/p-Si/Al device is attributed to the variation of the surface or interface states distribution for the devices. The reverse and forward bias currents relatively increased after x-ray irradiation because of the decrease in bulk lifetime. In addition, ATR-FTIR spectra of anthraquinone and pyridine films showed that pyridine is more stable than anthraquinone under x-ray irradiation. - Highlights: • Two junction devices based on organic materials were fabricated. • The effect of the x-ray irradiation on devices were examined. • Both devices showed x-irradiation-dependence.

  1. Assiut Experience in the Application of Holmium Laser in Treatment ...

    African Journals Online (AJOL)

    Assiut Experience in the Application of Holmium Laser in Treatment of Ureteral Calculi in Adults. A.M. Abdel Lateef, A.E. Abdel Moniem, M.I. Taha, M.A. Shalaby. Abstract. Internal Optical Urethrotomy at the National Medical Center of Sanou Souro in Bobo-Dioulasso: Feasibility, Safety and Short-Term Results Objective To ...

  2. Evaluation of holmium laser versus cold knife in optical internal urethrotomy for the management of short segment urethral stricture.

    Science.gov (United States)

    Jain, Sudhir Kumar; Kaza, Ram Chandra Murthy; Singh, Bipin Kumar

    2014-10-01

    SACHSE COLD KNIFE IS CONVENTIONALLY USED FOR OPTICAL INTERNAL URETHROTOMY INTENDED TO MANAGE URETHRAL STRICTURES AND HO: YAG laser is an alternative to it. The aim of this study was to evaluate the role of urethral stricture treatment outcomes, efficacy, and complications using cold knife and Ho: YAG (Holmium laser) for optical internal urethrotomy. In this prospective study included, 90 male patients age >18 years, with diagnosis of urethral stricture admitted for internal optical urethrotomy during April 2010 to March 2012. The patients were randomized into two groups containing 45 patients each using computer generated random number. In group A (Holmium group), internal urethrotomy was done with Holmium laser and in group B (Cold knife group) Sachse cold knife was used. Patients were followed up for 6 months after surgery in Out Patient Department on 15, 30 and 180 post-operative days. At each follow up visit physical examination, and uroflowmetry was performed along with noting complaints, if any. The peak flow rates (PFR) were compared between the two groups on each follow up. At 180 days (6 month interval) the difference between mean of PFR for Holmium and Cold knife group was statistically highly significant (P knife urethrotomy.

  3. Poly(L-lactic acid) microspheres containing neutron-activatable holmium-165: a study of the physical characteristics of microspheres before and after irradiation in a nuclear reactor.

    Science.gov (United States)

    Mumper, R J; Jay, M

    1992-01-01

    The solvent evaporation technique was employed to prepare poly(L-lactic acid) (PLA) microspheres with 165Ho acetylacetonate (Ho-AcAc). Particle size, percentage Ho-165, percent residual solvent, and retentive ability of the spheres were found to be strongly affected by preparatory conditions. Differential scanning calorimetry (DSC) thermograms suggested that the Ho-AcAc existed in the PLA matrix as a molecular dispersion. High neutron flux irradiations of the PLA spheres in a nuclear reactor produced Ho-166, a therapeutic radionuclide that emits high-energy negatrons (Emax = 1.84 MeV; half-life = 26.9 hr). The gamma radiation dose (53-75 Mrad) from the core of the reactor provided an overkill of all bioburdens in the PLA spheres. Gel permeation chromatography (GPC) analysis showed that these irradiations caused a reduction in PLA molecular weight. Infrared spectra, 13C NMR spectra, 1H NMR spectra, and DSC thermograms further confirmed the presence of lower molecular weight PLA but proved the overall maintenance of PLA structure.

  4. Development of a Device for a Material Irradiation Test in the OR Test Hole

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Kang, Y. H.; Kim, B. G.; Choo, K. N.; Sohn, J. M.; Shin, Y. T.; Park, S. J.; Seo, C. K

    2008-05-15

    To develop a technology and a device for the irradiation test for utilization of the OR/IP holes according to the various requirements of users, the properties of the OR/IP holes were investigated and an irradiation device for the OR hole was designed and fabricated. The OR-4, 5 and the IP-9, 10, 11 holes were selected as those suitable to irradiation tests among the test holes located in the out core area. The conceptual design was performed to design a device to irradiate materials using the OR and IP holes. The capsule for the OR holes is fixed by pressing the protection tube using a clamping device, on the other hand the IP capsule is inserted in the hole without a special clamping device. In the basic design of the irradiation device for the OR hole, the capsules having the outside diameter of 50, 52, 54, 56mm were reviewed theoretically to investigate if they meet the hydraulic and vibration conditions required in the HANARO. The results of the pressure drop test showed that the 3 kinds of capsules having diameter of 52, 54, 56mm satisfied the requirement for the pressure difference and flow rate in HANARO. The capsule of {phi}56mm out of the above three satisfied the vibration condition and was finally selected giving consideration of a capacity of specimens. The capsule having a diameter of {phi}56mm was fabricated and the flow rate was measured. Using the velocity data measured at the out-core facility, the heat transfer coefficient, and the temperature on the surface of the capsule was evaluated to confirm it less than the ONB temperature. As a result, the capsule of {phi}56mm was selected for the irradiation test at the OR holes.

  5. Proton irradiation of a swept charge device at cryogenic temperature and the subsequent annealing

    International Nuclear Information System (INIS)

    Gow, J P D; Smith, P H; Hall, D J; Holland, A D; Murray, N J; Pool, P

    2015-01-01

    A number of studies have demonstrated that a room temperature proton irradiation may not be sufficient to provide an accurate estimation of the impact of the space radiation environment on detector performance. This is a result of the relationship between defect mobility and temperature, causing the performance to vary subject to the temperature history of the device from the point at which it was irradiated. Results measured using Charge Coupled Devices (CCD) irradiated at room temperature therefore tend to differ from those taken when the device was irradiated at a cryogenic temperature, more appropriate considering the operating conditions in space, impacting the prediction of in-flight performance. This paper describes the cryogenic irradiation, and subsequent annealing of an e2v technologies Swept Charge Device (SCD) CCD236 irradiated at −35.4°C with a 10 MeV equivalent proton fluence of 5.0 × 10 8 protons · cm −2 . The CCD236 is a large area (4.4 cm 2 ) X-ray detector that will be flown on-board the Chandrayaan-2 and Hard X-ray Modulation Telescope spacecraft, in the Chandrayaan-2 Large Area Soft X-ray Spectrometer and the Soft X-ray Detector respectively. The SCD is readout continually in order to benefit from intrinsic dither mode clocking, leading to suppression of the surface component of the dark current and allowing the detector to be operated at warmer temperatures than a conventional CCD. The SCD is therefore an excellent choice to test and demonstrate the variation in the impact of irradiation at cryogenic temperatures in comparison to a more typical room temperature irradiation

  6. Holmium laser enucleation versus laparoscopic simple prostatectomy for large adenomas.

    Science.gov (United States)

    Juaneda, R; Thanigasalam, R; Rizk, J; Perrot, E; Theveniaud, P E; Baumert, H

    2016-01-01

    The aim of this study is to compare Holmium laser enucleation of the prostate with another minimally invasive technique, the laparoscopic simple prostatectomy. We compared outcomes of a series of 40 patients who underwent laparoscopic simple prostatectomy (n=20) with laser enucleation of the prostate (n=20) for large adenomas (>100 grams) at our institution. Study variables included operative time and catheterization time, hospital stay, pre- and post-operative International Prostate Symptom Score and maximum urinary flow rate, complications and economic evaluation. Statistical analyses were performed using the Student t test and Fisher test. There were no significant differences in patient age, preoperative prostatic size, operating time or specimen weight between the 2 groups. Duration of catheterization (P=.0008) and hospital stay (P.99). Holmium enucleation of the prostate has similar short term functional results and complication rates compared to laparoscopic simple prostatectomy performed in large glands with the advantage of less catheterization time, lower economic costs and a reduced hospital stay. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Safety and feasibility research of CIPT-Ⅱ irradiation device

    International Nuclear Information System (INIS)

    Zhang Zhihua; Mi Xiangmiao; Li Rundong

    2014-01-01

    CITP-Ⅱ irradiation device, which is specially designed for fusion tritium breeder research, works in a thermal neutron reactor. With lithium orthosilicate as the breeder, the safety analysis was done to work out the device's influence on physical parameters of the reactor and get the breeder's temperature distribution and thermo-technical features in the n-γ field. The stiffness and strength were checked, and also the safety characters of the device were assessed. The feasibility of gap gas regulating the temperature and gas refueling the breeder was demonstrated. The calculation and analysis results provide data for comprehensive performance assessment. (authors)

  8. Ultraviolet spectral distribution and erythema-weighted irradiance from indoor tanning devices compared with solar radiation exposures.

    Science.gov (United States)

    Sola, Yolanda; Baeza, David; Gómez, Miguel; Lorente, Jerónimo

    2016-08-01

    Concern regarding the impact of indoor tanning devices on human health has led to different regulations and recommendations, which set limits on erythema-weighted irradiance. Here, we analyze spectral emissions from 52 tanning devices in Spanish facilities and compare them with surface solar irradiance for different solar zenith angles. Whereas most of the devices emitted less UV-B radiation than the midday summer sun, the unweighted UV-A irradiance was 2-6 times higher than solar radiation. Moreover, the spectral distributions of indoor devices were completely different from that of solar radiation, differing in one order of magnitude at some UV-A wavelengths, depending on the lamp characteristics. In 21% of the devices tested, the erythema-weighted irradiance exceeded 0.3Wm(-2): the limit fixed by the European standard and the Spanish regulation. Moreover, 29% of the devices fall within the UV type 4 classification, for which medical advice is required. The high variability in erythema-weighted irradiance results in a wide range of exposure times to reach 1 standard erythemal dose (SED: 100Jm(-2)), with 62% of devices requiring exposures of UV-A dose during this time period would be from 1.4 to 10.3 times more than the solar UV-A dose. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Clinical implementation of a new HDR brachytherapy device for partial breast irradiation

    International Nuclear Information System (INIS)

    Scanderbeg, Daniel J.; Yashar, Catheryn; Rice, Roger; Pawlicki, Todd

    2009-01-01

    Purpose: To present the clinical implementation of a new HDR device for partial breast irradiation, the Strut-Adjusted Volume Implant (SAVI), at the University of California, San Diego. Methods and materials: The SAVI device has multiple peripheral struts that can be differentially loaded with the HDR source. Planning criteria used for evaluation of the treatment plans included the following dose volume histogram (DVH) criteria: V90 >90%, V150 <50 cc and V200 <20 cc. Results: SAVI has been used on 20 patients to date at UC San Diego. In each case, the dose was modulated according to patient-specific anatomy to cover the tumor bed, while sparing normal tissues. The dosimetric data show that we can achieve greater than 90% coverage with respect to V90 (median of 95.3%) and also keep a low V150 and V200 dose at 24.5 and 11.2 cc, respectively. Complete treatment can be done within a 30-min time slot, which includes implant verification, setup, and irradiation time as well as wound dressing. Conclusion: SAVI has been implemented at UC San Diego for accelerated partial breast irradiation with excellent tumor bed conformance and minimal normal tissue exposure. Patient positioning is the key to identifying any inter-fraction device motion. Device asymmetry or tissue conformance has been shown to resolve itself 24 h after the device implantation. The device can be implemented into an existing HDR program with minimal effort

  10. Effects of DD and DT neutron irradiation on some Si devices for fusion diagnostics

    International Nuclear Information System (INIS)

    Tanimura, Y.; Iida, T.

    1998-01-01

    In order to examine the difference in the irradiation effects on Si devices between DT and DD neutrons, CCD image sensors, memory ICs and a Si detector were irradiated with neutrons from a deuteron accelerator. The transient effects (i.e. neutron-induced background noises) and permanent effects (i.e. neutron damage) on them were in situ measured during irradiation. Regarding the transient effects, brightening spot noises, soft-error upsets and induced-charge noises were measured for the CCDs, memory ICs and Si detector, respectively. As for the permanent effect, the number of damaged cells of the CCDs and the leakage current of the Si detector increased with neutron fluence. Also we developed a Monte-Carlo code with the TRIM code to evaluate the correlation of DT and DD neutron effects on Si devices. The calculated correlation factor of DT and DD neutron damage for Si devices agreed approximately with the correlation factor obtained from the irradiation experiments on the CCDs and Si detector. (orig.)

  11. Effects of DD and DT neutron irradiation on some Si devices for fusion diagnostics

    Science.gov (United States)

    Tanimura, Yoshihiko; Iida, Toshiyuki

    1998-10-01

    In order to examine the difference in the irradiation effects on Si devices between DT and DD neutrons, CCD image sensors, memory ICs and a Si detector were irradiated with neutrons from a deuteron accelerator. The transient effects (i.e. neutron-induced background noises) and permanent effects (i.e. neutron damage) on them were in situ measured during irradiation. Regarding the transient effects, brightening spot noises, soft-error upsets and induced-charge noises were measured for the CCDs, memory ICs and Si detector, respectively. As for the permanent effect, the number of damaged cells of the CCDs and the leakage current of the Si detector increased with neutron fluence. Also we developed a Monte-Carlo code with the TRIM code to evaluate the correlation of DT and DD neutron effects on Si devices. The calculated correlation factor of DT and DD neutron damage for Si devices agreed approximately with the correlation factor obtained from the irradiation experiments on the CCDs and Si detector.

  12. The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode.

    Science.gov (United States)

    Szewczyk, Mariusz; Jesionek-Kupnicka, Dorota; Lipiński, Marek Ireneusz; Lipinski, Piotr; Różański, Waldemar

    2014-01-01

    The aim of this study is to compare the changes in the incision line of prostatic adenoma using a monopolar cutting electrode and holmium laser, as well as the assessment of associated tissue mass and volume loss of benign prostatic hyperplasia (BPH). The material used in this study consisted of 74 preparations of prostatic adenoma obtained via open retropubic adenomectomy, with an average volume of 120.7 ml. The material obtained cut in vitro before fixation in formaldehyde. One lobe was cut using holmium laser, the other using a monopolar cutting electrode. After the incision was made, tissue mass and volume loss were evaluated. Thermocoagulation changes in the incision line were examinedunder light microscope. In the case of the holmium laser incision, the average tissue mass loss was 1.73 g, tissue volume loss 3.57 ml and the depth of thermocoagulation was 1.17 mm. When the monopolar cutting electrode was used average tissue mass loss was 0.807 g, tissue volume loss 2.48 ml and the depth of thermocoagulation was 0.19 mm. Where holmium laser was used, it was observed that the layer of tissue with thermocoagulation changes was deeper than in the case of the monopolar cutting electrode. Moreover, it was noticed that holmium laser caused bigger tissue mass and volume loss than the cutting electrode.

  13. Dielectric and conducting behaviour of polycrystalline holmium octa-molybdate

    International Nuclear Information System (INIS)

    Want, Basharat; Zahoor Ahmad, Bhat; Hamid Bhat, Bilal

    2014-01-01

    Polycrystalline holmium octa-molybdate spherulites have been obtained by using gel diffusion technique and characterized by different physio-chemical techniques. The surfaces of these spherulites are composed of nano-rod with an average diameter of about 80 nm. At room temperature the initial crystal structure is triclinic, space group P1. Thermal studies suggested a phase transition occurring in holmium octa-molybdate crystals at about 793 K. The electrical properties of the system have been studied as a function of frequency and temperature in the ranges of 20 Hz–3 MHz and 290–570 K, respectively. A giant dielectric constant and two loss peaks have been observed in the permittivity formalism. The conducting behaviour of the material is also discussed. The conductivity was found to be 1572 μ Ω −1 m −1 at room temperature and 3 MHz frequency. The conductivity of the polycrystalline material was attributed to the fact that it arises due to the migration of defects on the oxygen sub-lattice. Impedance studies were also performed in the frequency domain to infer the bulk and grain boundary contributions to the overall electric response of the material. The electrical responses have been attributed to the grain, grain-boundary, and interfacial effects. (paper)

  14. Specific heat of holmium and YNi{sub 2}B{sub 2}C. Criticalbehaviour and superconducting properties; Spezifische Waerme von Holmium und YNi{sub 2}B{sub 2}C. Kritisches Verhalten und supraleitende Eigenschaften

    Energy Technology Data Exchange (ETDEWEB)

    Bekkali, Abdelhakim

    2010-01-04

    Object of the thesis is the study of the specific heat of holmium and YNi{sub 2}B{sub 2}C in the temperature ranges from 50 to 200 KI respectively from 380 mK to 20 K in magnetic fields up to 9 T. In the present thesis the criticalbehaviour of YNi{sub 2}B{sub 2}C and properties of the superconducting state of tne non-magnetic rare-earth nickel borocarbide YNi{sub 2}B{sub 2}C are studied by means of a self-developed measurement apparatur of the specific heat using the quasi-adiabatic heating-pulse method as well as of holmium by means of the relaxation method. In this thesis reliable statements about the critical exponents on monocrystalline holmium could be made. The study on holmium proves that the critical behaviour of the specific heats cannot be described in the framework of the predictions of the chiral universality classes. By means of measurements of the specific heat in this thesis could be confirmed that YNi{sub 2}B{sub 2}C is a multiband superconductor. The positive curvature of the boundary line below T{sub c} in the phase diagram yields a first hint to the many-band character of YNI{sub 2}B{sub 2}C. In the zero-field the electronic specific heat in the superconducting state c{sub es}(T) can be not explained in the framework of the pure BCS theory. At low temperatures a residual contribution by normally conducting electrons could be detected, which hints to a not completely opened energy gap. A possible explanation would be that a band (or several bands) with low charge-carrier concentration not contribute to the superconductivity. This result agrees with de Haas-van Alphen measurements on isostructural superconducting LuNi{sub 2}B{sub 2}C monocrystals, which suggest the many-band character of the superconductivity as well as a vanishing energy gap in one band. The fluctuation behaviour of the specific heat of YNi{sub 2}B{sub 2}C in the neighbourhood of the superconducting-normally conducting transition agrees well with that of the 3D-XY model. [German

  15. Biological samples positioning device for irradiations on a radial channel at the nuclear research reactor

    International Nuclear Information System (INIS)

    Rodriguez Gual, Maritza; Mas Milian, Felix; Deppman, Airton; Pinto Coelho, Paulo Rogerio

    2010-01-01

    For the demand of an experimental device for biological samples positioning system for irradiations on a radial channel at the nuclear research reactor in operation was constructed and started up a device for the place and remove of the biological samples from the irradiation channels without interrupting the operation of the reactor. The economical valuations are effected comparing with another type of device with the same functions. This work formed part of an international project between Cuba and Brazil that undertook the study of the induced damages by various types of ionizing radiation in DNA molecules. Was experimentally tested the proposed solution, which demonstrates the practical validity of the device. As a result of the work, the experimental device for biological samples irradiations are installed and operating in the radial beam hole No3(BH3) for more than five years at the IEA-R1 Brazilian research reactor according to the solicited requirements the device. The designed device increases considerably the type of studies can be conducted in this reactor. Its practical application in research taking place in that facility, in the field of radiobiology and dosimetry, and so on is immediate

  16. An automatic device for sample insertion and extraction to/from reactor irradiation facilities

    International Nuclear Information System (INIS)

    Alloni, L.; Venturelli, A.; Meloni, S.

    1990-01-01

    At the previous European Triga Users Conference in Vienna,a paper was given describing a new handling tool for irradiated samples at the L.E.N.A plant. This tool was the first part of an automatic device for the management of samples to be irradiated in the TRIGA MARK ii reactor and successively extracted and stored. So far sample insertion and extraction to/from irradiation facilities available on reactor top (central thimble,rotatory specimen rack and channel f),has been carried out manually by reactor and health-physics operators using the ''traditional'' fishing pole provided by General Atomic, thus exposing reactor personnel to ''unjustified'' radiation doses. The present paper describes the design and the operation of a new device, a ''robot''type machine,which, remotely operated, takes care of sample insertion into the different irradiation facilities,sample extraction after irradiation and connection to the storage pits already described. The extraction of irradiated sample does not require the presence of reactor personnel on the reactor top and,therefore,radiation doses are strongly reduced. All work from design to construction has been carried out by the personnel of the electronic group of the L.E.N.A plant. (orig.)

  17. Specific heat of holmium and YNi2B2C. Criticalbehaviour and superconducting properties

    International Nuclear Information System (INIS)

    Bekkali, Abdelhakim

    2010-01-01

    Object of the thesis is the study of the specific heat of holmium and YNi 2 B 2 C in the temperature ranges from 50 to 200 KI respectively from 380 mK to 20 K in magnetic fields up to 9 T. In the present thesis the criticalbehaviour of YNi 2 B 2 C and properties of the superconducting state of tne non-magnetic rare-earth nickel borocarbide YNi 2 B 2 C are studied by means of a self-developed measurement apparatur of the specific heat using the quasi-adiabatic heating-pulse method as well as of holmium by means of the relaxation method. In this thesis reliable statements about the critical exponents on monocrystalline holmium could be made. The study on holmium proves that the critical behaviour of the specific heats cannot be described in the framework of the predictions of the chiral universality classes. By means of measurements of the specific heat in this thesis could be confirmed that YNi 2 B 2 C is a multiband superconductor. The positive curvature of the boundary line below T c in the phase diagram yields a first hint to the many-band character of YNI 2 B 2 C. In the zero-field the electronic specific heat in the superconducting state c es (T) can be not explained in the framework of the pure BCS theory. At low temperatures a residual contribution by normally conducting electrons could be detected, which hints to a not completely opened energy gap. A possible explanation would be that a band (or several bands) with low charge-carrier concentration not contribute to the superconductivity. This result agrees with de Haas-van Alphen measurements on isostructural superconducting LuNi 2 B 2 C monocrystals, which suggest the many-band character of the superconductivity as well as a vanishing energy gap in one band. The fluctuation behaviour of the specific heat of YNi 2 B 2 C in the neighbourhood of the superconducting-normally conducting transition agrees well with that of the 3D-XY model. [de

  18. Gamma irradiation devices

    International Nuclear Information System (INIS)

    Foeldiak, Gabor; Stenger, Vilmos.

    1983-01-01

    The main parameters and the preparation procedures of the gamma radiation sources frequently applied for irradiation purposes are discussed. In addition to 60 Co and 137 Cs sources also the nuclear power plants offer further opportunities: spent fuel elements and products of certain (n,γ) reactions can serve as irradiation sources. Laboratory scale equipments, pilot plant facilities for batch or continuous operation, continuous industrial irradiators and special multipurpose, mobile and panorama type facilities are reviewed including those in Canada, USA, India, the Soviet Union, Hungary, UK, Japan and Australia. For irradiator design the source geometry dependence of the spatial distribution of dose rates can be calculated. (V.N.)

  19. The Polycistronic miR166k-166h Positively Regulates Rice Immunity via Post-transcriptional Control of EIN2

    Directory of Open Access Journals (Sweden)

    Raquel Salvador-Guirao

    2018-03-01

    Full Text Available MicroRNAs (miRNAs are small RNAs acting as regulators of gene expression at the post-transcriptional level. In plants, most miRNAs are generated from independent transcriptional units, and only a few polycistronic miRNAs have been described. miR166 is a conserved miRNA in plants targeting the HD-ZIP III transcription factor genes. Here, we show that a polycistronic miRNA comprising two miR166 family members, miR166k and miR166h, functions as a positive regulator of rice immunity. Rice plants with activated MIR166k-166h expression showed enhanced resistance to infection by the fungal pathogens Magnaporthe oryzae and Fusarium fujikuroi, the causal agents of the rice blast and bakanae disease, respectively. Disease resistance in rice plants with activated MIR166k-166h expression was associated with a stronger expression of defense responses during pathogen infection. Stronger induction of MIR166k-166h expression occurred in resistant but not susceptible rice cultivars. Notably, the ethylene-insensitive 2 (EIN2 gene was identified as a novel target gene for miR166k. The regulatory role of the miR166h-166k polycistron on the newly identified target gene results from the activity of the miR166k-5p specie generated from the miR166k-166h precursor. Collectively, our findings support a role for miR166k-5p in rice immunity by controlling EIN2 expression. Because rice blast is one of the most destructive diseases of cultivated rice worldwide, unraveling miR166k-166h-mediated mechanisms underlying blast resistance could ultimately help in designing appropriate strategies for rice protection.

  20. 7 CFR 1427.166 - Insurance.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Insurance. 1427.166 Section 1427.166 Agriculture... AGRICULTURE LOANS, PURCHASES, AND OTHER OPERATIONS COTTON Recourse Seed Cotton Loans § 1427.166 Insurance. The seed cotton must be insured at the full loan value against loss or damage by fire. ...

  1. Irradiations at low temperatures. 1. part: devices designs; Les irradiations aux basses temperatures. Premiere partie: conception des dispositifs

    Energy Technology Data Exchange (ETDEWEB)

    Conte, R.R. [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    After an attempt to sort out the irradiation devices, the different refrigeration systems used: stored liquid or refrigerators, are presented. Some financial aspects of these two systems are discussed. For a long run, 1000 hr per year (100 hr for He) the refrigerator become less expensive than stored liquid devices. Some ideas about the principal criterions in the device design are discussed. Finally a few elements making easier the calculation of the different parts of a cryostat are given. (author) [French] Apres un essai de classification des dispositifs d'irradiation, on presente les divers modes de refrigeration: liquides stockes ou refrigerateurs. On discute quelques aspects financiers des deux principes. Il apparait que pour des durees de fonctionnement d'environ 1 000 heures par an les refrigerateurs deviennent plus rentables (-100 heures pour He). On classe ensuite quelques idees sur les principaux criteres de conception des dispositifs. Enfin on donne quelques elements facilitant le calcul des differentes parties d'un cryostat. (auteur)

  2. Irradiations at low temperatures. 1. part: devices designs; Les irradiations aux basses temperatures. Premiere partie: conception des dispositifs

    Energy Technology Data Exchange (ETDEWEB)

    Conte, R R [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    After an attempt to sort out the irradiation devices, the different refrigeration systems used: stored liquid or refrigerators, are presented. Some financial aspects of these two systems are discussed. For a long run, 1000 hr per year (100 hr for He) the refrigerator become less expensive than stored liquid devices. Some ideas about the principal criterions in the device design are discussed. Finally a few elements making easier the calculation of the different parts of a cryostat are given. (author) [French] Apres un essai de classification des dispositifs d'irradiation, on presente les divers modes de refrigeration: liquides stockes ou refrigerateurs. On discute quelques aspects financiers des deux principes. Il apparait que pour des durees de fonctionnement d'environ 1 000 heures par an les refrigerateurs deviennent plus rentables (-100 heures pour He). On classe ensuite quelques idees sur les principaux criteres de conception des dispositifs. Enfin on donne quelques elements facilitant le calcul des differentes parties d'un cryostat. (auteur)

  3. Our first clinical experience with radiosynoviorthesis by means of 166

    Czech Academy of Sciences Publication Activity Database

    Kraft, O.; Kašpárek, R.; Ullmann, V.; Melichar, František; Kropáček, Martin; Mirzajevová, Marcela

    2005-01-01

    Roč. 8, č. 2 (2005), s. 131-134 ISSN 1506-9680 R&D Projects: GA AV ČR(CZ) 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : holmium * radiotherapy Subject RIV: CH - Nuclear ; Quantum Chemistry

  4. 17 CFR 166.3 - Supervision.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Supervision. 166.3 Section 166.3 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION CUSTOMER PROTECTION RULES § 166.3 Supervision. Each Commission registrant, except an associated person who has no supervisory duties, must diligently supervise the handling b...

  5. Radioactive ceramic seeds with Ho-166 and Sm-153 with perspective of use in brachytherapy

    International Nuclear Information System (INIS)

    Valente, Eduardo Sarmento

    2010-01-01

    This work aimed to characterize physically, chemically and radioactively ceramics seeds with holmium and samarium embedded in ceramic matrix produced by sol-gel route. Biological response of HeLa cells was investigated macroscopically in vitro under the exposure to β radiation of Ho-166 and Sm-153. The dispersal of radioactive material in simulated body fluid (SBF) was made and the dose rate and total dose deposited in the volume delimited by the range of β particles in the water was calculated. The methodology used in physical, chemical and nuclear characterization was based on the following techniques: atomic emission spectrometry, neutron activation analysis, gamma spectrometry, X-ray fluorescence spectrometry and X-rays diffraction. In addition to the solubility in SBF, an in vivo pilot study assessed the dispersion of radioactive seeds implanted in rabbit muscle tissue. Four experiments were prepared to investigate the biological response in vitro, in which radioactive seeds were placed directly in contact with the cells in confluent culture flasks. The first two were done with seed's activity of 3.7 MBq (0.1 mCi) for the Sm-153 and 11.1 MBq (0.3 mCi) for Ho-166. There were no concerns with spatial positioning for seeds in those early experiments. The subsequent experiments were performed with activity ranging from 37 MBq (1 mCi) and 111 MBq (3 mCi) and with defined position of the seeds in the flask. The results showed the presence of halos with maximum diameter of 8 mm around the seeds where there was a drastic reduction in the number of viable cells as a result of the effects of β radiation. The calculation of dose deposited in water as well as the dose rate calculation of during handling of the seeds for an implant followed the methodology established by MIRD. These calculations found dose rates ranging from 7 to 19 Gy/h and integrated doses between 93 and 730 Gy, due to β radiation, for 6 half-lives of radioisotopes Sm-153 and Ho-166. The dose

  6. A holmium(III)-based single-molecule magnet with pentagonal-bipyramidal geometry

    Energy Technology Data Exchange (ETDEWEB)

    Kajiwara, Takashi [Department of Chemistry, Faculty of Science, Nara Women' s University (Japan)

    2017-09-11

    The right environment: The remarkable properties of a recently reported holmium(III)-based single-ion magnet have been ascribed to the hyperfine interactions with the half-integer nuclear spin in combination with the pentagonal-bipyramidal coordination environment. These results provide insight into the complicated magnetic properties of nanosized magnetic materials. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  7. Mobile computing device configured to compute irradiance, glint, and glare of the sun

    Science.gov (United States)

    Gupta, Vipin P; Ho, Clifford K; Khalsa, Siri Sahib

    2014-03-11

    Described herein are technologies pertaining to computing the solar irradiance distribution on a surface of a receiver in a concentrating solar power system or glint/glare emitted from a reflective entity. A mobile computing device includes at least one camera that captures images of the Sun and the entity of interest, wherein the images have pluralities of pixels having respective pluralities of intensity values. Based upon the intensity values of the pixels in the respective images, the solar irradiance distribution on the surface of the entity or glint/glare corresponding to the entity is computed by the mobile computing device.

  8. Development of a method of testing irradiation devices by gamma scanning inside a research nuclear reactor

    International Nuclear Information System (INIS)

    Michel, Francois.

    1975-01-01

    A tridimensional experiment of spectrometry of an irradiation device located inside the reactor Siloe at a place shielded against spurious radiations, is exposed. The automatic scanning system that was developed, makes it possible to fully analyze in about 24 hours, the irradiation device (fuel pin, coolant and structures). The process combined with a 'pre-processing' program allows first partial results to be simultaneously obtained, more refined results being achieved during the next week, using the 'heavy processing'. The irradiation of the device is only interrupted during the compelling duty shutdown of the reactor, the evolution of the device during the successive irradiation cycles being thus followed up without pertubing said evolution. The reproducibility was studied at a local stage for testing the collimation of the detection unit (1% accuracy) and for testing the whole set 'processing measurement and computation' (5% accuracy). The sensitivity has been illustrated by detecting and measuring local singularities inside fuel (pellets), determining the detection efficiency dependence on the radial distribution of fission products and measuring nucleides inside the coolant flow (limiting value 10 -7 ). The accuracy of the method is evaluated at 5% for relative measurement of an experimental device during its in-pile lifetime and as 10% for quantitative absolute measurements [fr

  9. Device to irradiate agricultural product on the production site, after harvesting

    International Nuclear Information System (INIS)

    Jegu, Jean; Palomo, Georges; Blaive, Daniel.

    1982-01-01

    The invention concerns a device to irradiate agricultural product on the production site, after harvesting. It includes an outer shielding to absorb the radiations and containers in which the products are placed for irradiation. The shielding is rotationally symmetrical around a vertical axis and holds an irradiation chamber containing a radioactive bar fitted along the shielding axis. The cylindrical containers are placed around the chamber with their axes parallel to the axis of the shielding. They are set in rotation by a motor and receive the farm products through their top ends which communicate with a supply system. Their bottom ends are closed by shutters covering a means for evacuating the products. The invention applies in particular to the irradiation of newly dug potatoes to avoid germination [fr

  10. Conceptual design for irradiation device used to irradiate experimental LFR fuel element in TRIGA reactor, ACPR zone

    International Nuclear Information System (INIS)

    Ioan, M.

    2013-01-01

    The paper presents the main steps followed to conceive a small, versatile and rather cheep irradiation device used for irradiation of an experimental fuel element, specific for Lead cooled Fast Reactor (LFR), adapted to TRIGA reactor, ACPR zone. This device must be instrumented with at least 4 thermocouples and a pressure transducer. The fuel element (150 mm fuel pellets column) will be immersed in maximum 0.350 kg pure hot lead (400 deg C). The system has three protection barriers, as follows: first is the fuel tube, second is the lead container (maximum 20 mm inner diameter) and third is the external container (maximum 180 mm outside diameter). Before the reactor pulse, the temperature of the lead is set at the prescribed value using an electrical heater (300 W), coil on the second barrier. Outside the second barrier a very good thermal insulation is provided. (authors)

  11. Holmium laser vs. conventional (cold knife) direct visual internal urethrotomy for short-segment bulbar urethral stricture: Outcome analysis.

    Science.gov (United States)

    Jhanwar, Ankur; Kumar, Manoj; Sankhwar, Satya Narayan; Prakash, Gaurav

    2016-01-01

    Our goal was to analyze the outcome between holmium laser and cold knife direct visual internal urethrotomy (DVIU) for short-segment bulbar urethral stricture. We conducted a prospective study comprised of 112 male patients seen from June 2013 to December 2014. Inclusion criterion was short-segment bulbar urethral stricture (≤1.5cm). Exclusion criteria were prior intervention/urethroplasty, pan-anterior urethral strictures, posterior stenosis, urinary tract infection, and those who lost to followup. Patients were divided into two groups; Group A (n=58) included cold knife DVIU and group B (n=54) included holmium laser endourethrotomy patients. Patient followup included uroflowmetry at postoperative Day 3, as well as at three months and six months. Baseline demographics were comparable in both groups. A total of 107 patients met the inclusion criteria and five patients were excluded due to inadequate followup. Mean stricture length was 1.31 ± 0.252 cm (p=0.53) and 1.34 ± 0.251 cm in Groups A and B, respectively. Mean operating time in Group A was 16.3 ± 1.78 min and in Group B was 20.96 ± 2.23 min (p=0.0001). Five patients in Group A had bleeding after the procedure that was managed conservatively by applying perineal compression. Three patients in Group B had fluid extravasation postoperatively. Qmax (ml/s) was found to be statistically insignificant between the two groups at all followups. Both holmium laser and cold knife urethrotomy are safe and equally effective in treating short-segment bulbar urethral strictures in terms of outcome and complication rate. However, holmium laser requires more expertise and is a costly alternative.

  12. Solar Irradiance Measurements Using Smart Devices: A Cost-Effective Technique for Estimation of Solar Irradiance for Sustainable Energy Systems

    Directory of Open Access Journals (Sweden)

    Hussein Al-Taani

    2018-02-01

    Full Text Available Solar irradiance measurement is a key component in estimating solar irradiation, which is necessary and essential to design sustainable energy systems such as photovoltaic (PV systems. The measurement is typically done with sophisticated devices designed for this purpose. In this paper we propose a smartphone-aided setup to estimate the solar irradiance in a certain location. The setup is accessible, easy to use and cost-effective. The method we propose does not have the accuracy of an irradiance meter of high precision but has the advantage of being readily accessible on any smartphone. It could serve as a quick tool to estimate irradiance measurements in the preliminary stages of PV systems design. Furthermore, it could act as a cost-effective educational tool in sustainable energy courses where understanding solar radiation variations is an important aspect.

  13. WE-D-BRE-01: A Sr-90 Irradiation Device for the Study of Cutaneous Radiation Injury

    Energy Technology Data Exchange (ETDEWEB)

    Dorand, JE; Bourland, JD [Department of Radiation Oncology and Department of Physics, Wake Forest University, Winston-Salem, NC (United States); Burnett, LR [KeraNetics, LLC, Winston-Salem, NC (United States); Tytell, M [Department of Neurobiology and Anatomy, Wake Forest School of Medicine, Winston-Salem, NC (United States)

    2014-06-15

    Purpose: To determine dosimetric character for a custom-built Sr-90 beta irradiator designed for the study of Cutaneous Radiation Injury (CRI) in a porcine animal model. In the event of a radiological accident or terrorist event, Sr-90, a fission by-product, will likely be produced. CRI is a main concern due to the low energy and superficial penetration in tissue of beta particles from Sr-90. Seven 100 mCi plaque Sr-90 radiation sources within a custom-built irradiation device create a 40 mm diameter region of radiation-induced skin injury as part of a larger project to study the efficacy of a topical keratin-based product in CRI healing. Methods: A custom-built mobile irradiation device was designed and implemented for in vivo irradiations. Gafchromic™ EBT3 radiochromic film and a PTW Markus chamber type 23343 were utilized for dosimetric characterization of the beta fluence at the surface produced by this device. Films were used to assess 2-dimensional dose distribution and percent depth dose characteristics of the radiation field. Ion chamber measurements provided dose rate data within the field. Results: The radiation field produced by the irradiation device is homogeneous with high uniformity (∼5%) and symmetry (∼3%) with a steep dose fall-off with depth from the surface. Dose rates were determined to be 3.8 Gy/min and 3.3 Gy/min for film and ion chamber measurements, respectively. A dose rate of 3.4 Gy/min was used to calculate irradiation times for in vivo irradiations. Conclusion: The custom-built irradiation device enables the use of seven Sr-90 beta sources in an array to deliver a 40 mm diameter area of homogeneous skin dose with a dose rate that is useful for research purposes and clinically relevant for the induction of CRI. Doses of 36 and 42 Gy successfully produce Grade III CRI and are used in the study of the efficacy of KeraStat™. This project has been funded in whole or in part with Federal funds from the Biomedical Advanced Research and

  14. Bone dissemination of prostate cancer after holmium laser enucleation of the prostate: a case report and a review of the literature.

    Science.gov (United States)

    Koguchi, Dai; Nishi, Morihiro; Satoh, Takefumi; Shitara, Toshiya; Matsumoto, Kazumasa; Fujita, Tetsuo; Yoshida, Kazunari; Iwamura, Masatsugu

    2014-02-01

    We report a case of dissemination of prostate cancer after holmium laser enucleation of the prostate in an 80-year-old patient. The patient presented at hospital because of nocturia. Transrectal ultrasound-guided biopsy was carried out because of high serum prostate-specific antigen (3.55 ng/mL), but it showed no malignancies. Benign prostate hyperplasia was diagnosed, and he was started on an α1-blocker. Although the urinary symptom improved with silodosin, acute urinary retention occurred 3 years after therapy began. Holmium laser enucleation of the prostate for relief of bladder outlet obstruction enabled discharge of urine. Pathological examination of the resected tissue found adenocarcinoma with a high Gleason score, 4 + 5. Serum alkaline phosphatase increased rapidly after holmium laser enucleation, and bone scintigraphy confirmed multiple bone metastases. Prostate cancer, T1bN0M1b, was diagnosed. © 2013 The Japanese Urological Association.

  15. Development status of irradiation devices and instrumentation for material and nuclear fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Sohn, Jae Min; Choo, Kee Nam [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-04-15

    The High flux Advanced Neutron Application ReactOr (HANARO), an open-tank-in-pool type reactor, is one of the multi-purpose research reactors in the world. Since the commencement of HANARO's operations in 1995, a significant number of experimental facilities have been developed and installed at HANARO, and continued efforts to develop more facilities are in progress. Owing to the stable operation of the reactor and its frequent utilization, more experimental facilities are being continuously added to satisfy various fields of study and diverse applications. The irradiation testing equipment for nuclear fuels and materials at HANARO can be classified into capsules and the Fuel Test Loop (FTL). Capsules for irradiation tests of nuclear fuels in HANARO have been developed for use under the dry conditions of the coolant and materials at HANARO and are now successfully utilized to perform irradiation tests. The FTL can be used to conduct irradiation testing of a nuclear fuel under the operating conditions of commercial nuclear power plants. During irradiation tests conducted using these capsules in HANARO, instruments such as the thermocouple, Linear Variable Differential Transformer (LVDT), small heater, Fluence Monitor (F/M) and Self-Powered Neutron Detector (SPND) are used to measure various characteristics of the nuclear fuel and irradiated material. This paper describes not only the status of HANARO and the status and perspective of irradiation devices and instrumentation for carrying out nuclear fuel and material tests in HANARO but also some results from instrumentation during irradiation tests

  16. 34 CFR 668.166 - Excess cash.

    Science.gov (United States)

    2010-07-01

    ... the Secretary for the costs the Secretary incurred in providing that excess cash to the institution... 34 Education 3 2010-07-01 2010-07-01 false Excess cash. 668.166 Section 668.166 Education..., DEPARTMENT OF EDUCATION STUDENT ASSISTANCE GENERAL PROVISIONS Cash Management § 668.166 Excess cash. (a...

  17. 33 CFR 157.166 - Hydrocarbon emissions.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Hydrocarbon emissions. 157.166 Section 157.166 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED... Crude Oil Washing (COW) System on Tank Vessels Cow Operations § 157.166 Hydrocarbon emissions. If the...

  18. Conservation and diversification of the miR166 family in soybean and potential roles of newly identified miR166s.

    Science.gov (United States)

    Li, Xuyan; Xie, Xin; Li, Ji; Cui, Yuhai; Hou, Yanming; Zhai, Lulu; Wang, Xiao; Fu, Yanli; Liu, Ranran; Bian, Shaomin

    2017-02-01

    microRNA166 (miR166) is a highly conserved family of miRNAs implicated in a wide range of cellular and physiological processes in plants. miR166 family generally comprises multiple miR166 members in plants, which might exhibit functional redundancy and specificity. The soybean miR166 family consists of 21 members according to the miRBase database. However, the evolutionary conservation and functional diversification of miR166 family members in soybean remain poorly understood. We identified five novel miR166s in soybean by data mining approach, thus enlarging the size of miR166 family from 21 to 26 members. Phylogenetic analyses of the 26 miR166s and their precursors indicated that soybean miR166 family exhibited both evolutionary conservation and diversification, and ten pairs of miR166 precursors with high sequence identity were individually grouped into a discrete clade in the phylogenetic tree. The analysis of genomic organization and evolution of MIR166 gene family revealed that eight segmental duplications and four tandem duplications might occur during evolution of the miR166 family in soybean. The cis-elements in promoters of MIR166 family genes and their putative targets pointed to their possible contributions to the functional conservation and diversification. The targets of soybean miR166s were predicted, and the cleavage of ATHB14-LIKE transcript was experimentally validated by RACE PCR. Further, the expression patterns of the five newly identified MIR166s and 12 target genes were examined during seed development and in response to abiotic stresses, which provided important clues for dissecting their functions and isoform specificity. This study enlarged the size of soybean miR166 family from 21 to 26 members, and the 26 soybean miR166s exhibited evolutionary conservation and diversification. These findings have laid a foundation for elucidating functional conservation and diversification of miR166 family members, especially during seed development or

  19. Laser-based irradiation apparatus and methods for monitoring the dose-rate response of semiconductor devices

    Science.gov (United States)

    Horn, Kevin M [Albuquerque, NM

    2006-03-28

    A scanned, pulsed, focused laser irradiation apparatus can measure and image the photocurrent collection resulting from a dose-rate equivalent exposure to infrared laser light across an entire silicon die. Comparisons of dose-rate response images or time-delay images from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems allows precise identification of those specific age-affected circuit structures within a device that merit further quantitative analysis with targeted materials or electrical testing techniques. Another embodiment of the invention comprises a broad-beam, dose rate-equivalent exposure apparatus. The broad-beam laser irradiation apparatus can determine if aging has affected the device's overall functionality. This embodiment can be combined with the synchronized introduction of external electrical transients into a device under test to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure.

  20. Use of the Moses Technology to Improve Holmium Laser Lithotripsy Outcomes: A Preclinical Study.

    Science.gov (United States)

    Elhilali, Mostafa M; Badaan, Shadie; Ibrahim, Ahmed; Andonian, Sero

    2017-06-01

    To evaluate in vitro and in vivo effects of Moses technology in Holmium laser and to compare it with the Regular mode in terms of lithotripsy efficiency and laser-tissue interactions. The Lumenis ® Pulse™ P120H holmium laser system together with Moses D/F/L fibers were used to compare the Regular mode with the Moses modes in stone retropulsion by using a high-speed camera, and stone ablation efficiency. In addition, a porcine ureteroscopy model was used to assess stone fragmentation and dusting as well as laser-tissue interaction with the ureteral wall. After a laser pulse, in vitro stone displacement experiments showed a significant reduction in retropulsion when using the Moses mode. The stone movement was reduced by 50 times at 0.8 J and 10 Hz (p technology resulted in more efficient laser lithotripsy, in addition to significantly reduced stone retropulsion, and displayed a margin of safety that may result in a shorter procedural time and safer lithotripsy.

  1. Laparoscopy-assisted micropercutaneous choledocholithotripsy with holmium laser in a cholecystectomized patient: an initial report.

    Science.gov (United States)

    Gökçen, Kaan; Atabey, Mustafa; Gökçen, Pınar; Gökçe, Gökhan

    2017-12-01

    We present a novel minimally invasive technique, laparoscopy-assisted micropercutaneous choledocholithotripsy, for choledocholithiasis that cannot be treated with other endoscopic techniques. This technique includes standard laparoscopic exploration of the common bile duct, combined with an all-seeing needle and holmium laser lithotripsy. As is known, an all-seeing needle is used in micropercutaneous nephrolithotomy for middle-sized renal stones. In this technique, an all-seeing needle was inserted into the dilatated common bile duct under laparoscopic vision and then a lithotripsy procedure was performed with a holmium laser behind the biliary stent. A cholecystectomized female patient with a 21-mm stone in the common bile duct who previously underwent an unsuccessful endoscopic retrograde cholangiopancreatography procedure was operated on in our service with laparoscopy-assisted micropercutaneous choledocholithotomy without a T-tube. This novel procedure was completed uneventfully and the patient was discharged without any complications. In the future, this procedure will hopefully be a treatment modality in choledocholithiasis that cannot be treated by other minimally invasive techniques.

  2. 9 CFR 166.7 - Cooking standards.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cooking standards. 166.7 Section 166.7... HEALTH PROTECTION SWINE HEALTH PROTECTION General Provisions § 166.7 Cooking standards. (a) Garbage shall...) Garbage shall be agitated during cooking, except in steam cooking equipment, to ensure that the prescribed...

  3. 40 CFR 166.25 - Agency review.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Agency review. 166.25 Section 166.25... Health Exemptions § 166.25 Agency review. (a) General. The Agency will review all requests as... is needed. The Agency will review the application and other available data necessary to make a...

  4. The relevance of rare earth elements to nuclear medicine

    International Nuclear Information System (INIS)

    Cox, P.H.

    1998-01-01

    Full text: The lanthanides are an interesting series of metallic elements which have almost identical chemical characteristics and which offer a variety of radioisotopes with differing energy spectra suitable for open source therapy. Their inorganic salts tend to form chemically and biological stable colloids which have proved to be useful for intercavity therapies, in particular for synovectomy. Yttrium-90 silicate is a standard product for large joints with a thick synovium whilst for smaller joints Erbium-169, with its shorter tissue penetration, is more widely used for smaller joints to reduce the risk of radiation induced bone necrosis. Recently the development of an inert biodegradable colloid, chitosan, labelled with Holmium 166. for intercavity therapy of cystic brain tumours has been reported. Yttrium-90 has been chelated to peptide and antibody fragments for tumour targeting as a potentially more effective radionuclide than Iodine-131. The search for alternatives to Strontium-89 for the palliative treatment of pain arising from bone metastases has led to the introduction of diphosphonate complexes of Samarium-153, Lutetium-177 and Holmium-166. These complexes are of special interest because the radionuclides can be produced economically in developing countries. Terbium-149, an alpha emitter, has been mentioned as a possible therapeutic radionuclide. Yttrium-90 and Holmium-166 can an both be made available as generator products which is an added potential advantage for developing nuclear medical applications

  5. Design of device for testing in the gamma irradiator

    International Nuclear Information System (INIS)

    Mariano H, E.

    1991-02-01

    In eves of the recharge of the Gamma Irradiator, JS-6500 it was detected, that there was contamination in the container that housed the pencils of Co-60, coming from Argentina, country to which the ININ buys it recharges. It was determined that the contamination in the container was it interns and after discussing several solution options it was determined to manufacture a device to make a washing of the pencils. It was touch to the Management of Radiological Safety to determine the conceptual design of the device to make the washing and the way of operation of the same one. The Management of Prototypes and Models was responsibility of the mechanical design and its production. (Author)

  6. Device for the generation of homogeneous dose distributions in irradiated materials

    International Nuclear Information System (INIS)

    Leonhardt, J.; Schulze, H.; Boes, J.; Decker, U.; Schmidt, J.

    1985-01-01

    The invention has been directed at a device for the generation of homogeneous dose distributions in materials irradiated by charged particles. This device can be applied to the initiation of radiation-chemical reactions in solids, of cross-linking and vulcanizing reactors, of crystal defect annealings, etc. A movable absorber (e.g. a wedge or a solid of revolution) which periodically changes the energy of particles striking the specimen has been installed in the beam hole of the beam generating system

  7. Recoil and conversion electron considerations of the {sup 166}Dy/{sup 166}Ho in vivo generator

    Energy Technology Data Exchange (ETDEWEB)

    Zeevaart, J.R. [North-West Univ., Mmabatho (South Africa). CARST; Szuecs, Z. [Nesca (South African Nuclear Energy Corporation Ltd.), Pretoria (South Africa). Radiochemistry; Hungarian Academy of Sciences, Debrecen (Hungary). Inst. of Nuclear Research; Takacs, S.; Jarvis, N. [Hungarian Academy of Sciences, Debrecen (Hungary). Inst. of Nuclear Research; Jansen, D. [Nesca (South African Nuclear Energy Corporation Ltd.), Pretoria (South Africa). Radiochemistry

    2012-07-01

    The use of radionuclides as potential therapeutic radiopharmaceuticals is increasingly investigated. An important aspect is the delivery of the radionuclide to the target, i.e. the radionuclide is not lost from the chelating agent. For in vivo generators, it is not only the log K of complexation between the metal ion and the chelator that is important, but also whether the daughter radionuclide stays inside the chelator after decay of the parent radionuclide. In our previous work, we showed that the classical recoil effect is only applicable for decays with a Q value higher than 0.6 MeV (in the atomic mass range around 100). However, Zhernosekov et al. published a result for {sup 140}Nd/{sup 140}Pr (Q = 0.222 MeV) which indicated that > 95% of the daughter ({sup 140}Pr) was lost by a DOTA chelator upon decay of {sup 140}Nd. The authors ascribed this to the ''post-effect''. Their experiment was repeated with the {sup 166}Dy/{sup 166}Ho generator to ascertain whether our calculations were correct. It was found that 72% of the daughter ({sup 166}Ho) was liberated from the DOTA chelator, indicating that the 'post effect' does exist in contrast to our recoil calculations. Upon further investigation, we determined that one should not only consider recoil energy levels but also the mode of decay which was able to explain the partial recoil found for {sup 166}Dy/{sup 166}Ho. It is concluded for the {sup 166}Dy/{sup 166}Ho system that the low recoil energy of the daughter nucleus {sup 166}Ho is not a sufficient reason to rule out release of the nuclide from chelators. On the other hand, we found that the ratio of the {sup 166}Ho that gets released corresponds to the ratio of relaxation of Ho atoms via the Auger process. (orig.)

  8. Simultaneous determination of dysprosium, holmium and erbium in high purity rare earth oxides by second order derivative spectrophotometry

    International Nuclear Information System (INIS)

    Anbu, M.; Prasada Rao, T.; Iyer, C. S. P.; Damodaran, A. D.

    1996-01-01

    High purity individual rare earth oxides are increasingly used as major components in lasers (Y 2 O 3 ), phosphors (YVO 3 , Eu 2 O 3 ), magnetic bubble memory films (Gd 2 O 3 ) and refractive-index lenses and fibre optics (La 2 O 3 ). The determination of individual lanthanides in high purity rare earth oxides is a more important and difficult task. This paper reports the utilization of higher order derivative spectrophotometry for the simultaneous determination of dysprosium, holmium and erbium in high purity rare earth oxides. The developed procedure is simple, reliable and allows the determination of 0.001 to 0.2% of dysprosium, holmium and erbium in several rare earth. (author). 9 refs, 2 figs, 2 tabs

  9. Irradiation device

    International Nuclear Information System (INIS)

    Ransohoff, J.A.

    1984-01-01

    Carriers, after being loaded with product to be irradiated, are transported by an input-output conveyor system into an irradiation chamber where they are received in a horizontal arrangement on racks which may support different sizes and numbers of carriers. The racks are moved by a chamber conveyor system in an endless rectangular path about a radiation source. Packers shift the carriers on the racks to maintain nearest proximity to the radiation source. The carriers are shifted in position on each rack during successive rack cycles to produce even radiation exposure. The carriers may be loaded singly onto successive racks during a first cycle of movement thereof about the source, with loading of additional carriers, and/or unloading of carriers, onto each rack occurring on subsequent rack cycles of movement

  10. Synthesis, Characterization and Thermal Diffusivity of Holmium and Praseodymium Zirconates

    OpenAIRE

    Stopyra M.; Niemiec D.; Moskal G.

    2016-01-01

    A2B2O7 oxides with pyrochlore or defected fluorite structure are among the most promising candidates for insulation layer material in thermal barrier coatings. The present paper presents the procedure of synthesis of holmium zirconate Ho2Zr2O7 and praseodymium zirconate Pr2Zr2O7 via Polymerized-Complex Method (PCM). Thermal analysis of precursor revealed that after calcination at relatively low temperature (700°C) fine-crystalline, single-phase material is obtained. Thermal diffusivity was me...

  11. Synthesis and Characterization of Holmium-Doped Iron Oxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Maarten Bloemen

    2014-02-01

    Full Text Available Rare earth atoms exhibit several interesting properties, for example, large magnetic moments and luminescence. Introducing these atoms into a different matrix can lead to a material that shows multiple interesting effects. Holmium atoms were incorporated into an iron oxide nanoparticle and the concentration of the dopant atom was changed in order to determine its influence on the host crystal. Its magnetic and magneto-optical properties were investigated by vibrating sample magnetometry and Faraday rotation measurements. The luminescent characteristics of the material, in solution and incorporated in a polymer thin film, were probed by fluorescence experiments.

  12. Surface patterning of multilayer graphene by ultraviolet laser irradiation in biomolecule sensing devices

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Tien-Li, E-mail: tlchang@ntnu.edu.tw; Chen, Zhao-Chi

    2015-12-30

    Graphical abstract: - Highlights: • Direct UV laser irradiation on multilayer graphene was discussed. • Multilayer graphene with screen-printed process was presented. • Surface patterning of multilayer graphene at fluence threshold was investigated. • Electrical response of glucose in sensing devices can be studied. - Abstract: The study presents a direct process for surface patterning of multilayer graphene on the glass substrate as a biosensing device. In contrast to lithography with etching, the proposed process provides simultaneous surface patterning of multilayer graphene through nanosecond laser irradiation. In this study, the multilayer graphene was prepared by a screen printing process. Additionally, the wavelength of the laser beam was 355 nm. To perform the effective laser process with the small heat affected zone, the surface patterns on the sensing devices could be directly fabricated using the laser with optimal control of the pulse overlap at a fluence threshold of 0.63 J/cm{sup 2}. The unique patterning of the laser-ablated surface exhibits their electrical and hydrophilic characteristics. The hydrophilic surface of graphene-based sensing devices was achieved in the process with the pulse overlap of 90%. Furthermore, the sensing devices for controlling the electrical response of glucose by using glucose oxidase can be used in sensors in commercial medical applications.

  13. Influence of different irradiation facilities on the response of radioprotection devices

    International Nuclear Information System (INIS)

    Heeren de Oliveira, A.

    1984-05-01

    An EIC 1 extrapolation chamber, flushed with a methan based tissue equivalent gas is presented. This measuring device serves as a reference instrument to calibrate in tissue absorbed dose beta beams from different irradiation facilities; point radioactive sources, sources used with beam flattening filters, large area sources simulated by moving a point source. The source to detector distance has to be greater than 3 cm, requiring a transfer dosemeter for smaller distances. Influence of these different irradiation geometries has been studied on several radioprotection instruments (babyline, individual dosemeter, ionisation chamber), using three radionucleides: 147 Pm, 204 Tl, 90 Sr + 90 Y [fr

  14. Magnetic x-ray scattering studies of holmium using synchro- tron radiation

    International Nuclear Information System (INIS)

    Gibbs, D.; Moncton, D.E.; D'Amico, K.L.; Bohr, J.; Grier, B.H.

    1985-01-01

    We present the results of magnetic x-ray scattering experiments on the rare-earth metal holmium using synchrotron radiation. Direct high-resolution measurements of the nominally incommensurate magnetic satellite reflections reveal new lock-in behavior which we explain within a simple spin-discommensuration model. As a result of magnetoelastic coupling, the spin-discommensuration array produces additional x-ray diffraction satellites. Their observation further substantiates the model and demonstrates additional advantages of synchrotron radiation for magnetic-structure studies

  15. Fine- and hyperfine structure investigations of the even-parity configuration system of the atomic holmium

    Science.gov (United States)

    Stefanska, D.; Ruczkowski, J.; Elantkowska, M.; Furmann, B.

    2018-04-01

    In this work new experimental results concerning the hyperfine structure (hfs) for the even-parity level system of the holmium atom (Ho I) were obtained; additionally, hfs data obtained recently as a by-product in investigations of the odd-parity level system were summarized. In the present work the values of the magnetic dipole and the electric quadrupole hfs constants A and B were determined for 24 even-parity levels, for 14 of them for the first time. On the basis of these results, as well as on available literature data, a parametric study of the fine structure and the hyperfine structure for the even-parity configurations of atomic holmium was performed. A multi-configuration fit of 7 configurations was carried out, taking into account second-order of the perturbation theory. For unknown electronic levels predicted values of the level energies and hfs constants are given, which can facilitate further experimental investigations.

  16. The application of x-ray spectrometry to isotopic-source activation analysis of dysprosium and holmium

    International Nuclear Information System (INIS)

    Pillay, A.E.; Mboweni, R.C.M.

    1990-01-01

    A novel aspect of activation analysis is described for the determination of dysprosium and holmium at low concentrations. The method involves the measurement of K x-rays from radionuclides produced by thermal neutron activation using a 1 mg 252 Cf source. The basis for elemental selection depends largely on the demand for analysis and on the existence of favourable nuclear properties for the production of a practicable x-ray yield. A full appraisal of the analytical potential of the method is presented with particular emphasis on its application to geological matrices. The sensitivity was optimised by employing a detector that was particularly effective at photon energies below 150 keV. Analytical conditions are demonstrated for the elements of interest over a wide range of concentrations in small powdered samples. The investigation formed the basis of a feasibility study to establish if the application could be developed for the routine off-line determination of dysprosium and holmium using an isotopic-neutron source. (author)

  17. Neutronic, thermal-hydraulics and safety calculations of a Miniplate Irradiation Device (MID) of dispersion type fuel elements

    International Nuclear Information System (INIS)

    Domingos, Douglas Borges

    2010-01-01

    Neutronic, thermal-hydraulics and accident analysis calculations were developed to estimate the safety of a Miniplate Irradiation Device (MID) to be placed in the IEA-R1 reactor core. The irradiation device is used to receive miniplates of U 3 O 8 -Al and U 3 Si 2 - Al dispersion fuels, LEU type (19.75 % 235 U) with uranium densities of, respectively, 3.2 gU/cm 3 and 4.8 gU/cm 3 . The fuel miniplates will be irradiated to nominal 235 U burnup levels of 50% and 80%, in order to qualify the above high-density dispersion fuels to be used in the Brazilian Multipurpose Reactor (RMB), now in the conception phase. For the neutronic calculation, the computer codes CITATION and 2DB were utilized. The computer code FLOW was used to calculate the coolant flow rate in the irradiation device, allowing the determination of the fuel miniplate temperatures with the computer model MTRCR-IEA-R1. A postulated Loss of Coolant Accident (LOCA) was analyzed with the computer codes LOSS and TEMPLOCA, allowing the calculation of the fuel miniplate temperatures after the reactor pool draining. The calculations showed that the irradiation should occur without adverse consequences in the IEA-R1 reactor. (author)

  18. Study of an automatized experimental device for the irradiation of a radioactive target

    International Nuclear Information System (INIS)

    Claverie, G.

    1996-01-01

    In order to solve the enigma of solar neutrinos, a team of physicians of the nuclear research center of Bordeaux-Gradignan and of the center of nuclear spectroscopy and mass spectroscopy of Orsay (France) decided to measure again the cross section of the beryllium-proton nuclear reaction at the lowest possible energies. This measurement requires the design of an automatized experimental device to irradiate in a specific way a beryllium target with an accelerated proton beam. The aim of this work is the study of such a device for an energy range of 800 to 300 KeV. This device comprises a particle multi-detector and a shutter for the irradiation of the target and the counting of the reaction products according to a programmable time sequence. The advantage of this setup is to allow an important bombardment of the target and to ensure its cooling. This device is automatically controlled thanks to a micro-controller, actuators (step motors and electrostatic deflector). It includes some beam diagnosis elements controlled by step motors and a target temperature monitoring system controlling a safety valve. The management of the experiment cell vacuum has led to the design of a vacuum monitor allowing the precise follow up of the vacuum and the control of the safety valves of the device. The nuclear instrumentation necessary to be implemented for this measurement is also presented. (J.S.)

  19. 17 CFR 166.2 - Authorization to trade.

    Science.gov (United States)

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Authorization to trade. 166.2 Section 166.2 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION CUSTOMER PROTECTION RULES § 166.2 Authorization to trade. No futures commission merchant, introducing broker or any of their...

  20. Irradiation devices for fusion reactor materials results obtained from irradiated lithium aluminate at the OSIRIS reactor

    International Nuclear Information System (INIS)

    Lefevre, F.; Thevenot, G.; Rasneur, B.; Botter, F.

    1986-06-01

    Studies about controlled fusion reactor of the Tokamak type require the examination of the radiation effects on the behaviour of various potential materials. Thus, in the first part of this paper, are presented the devices adapted to these materials studies and used in the OSIRIS reactor. In a second part, is described an experiment of irradiation ceramics used as candidates for breeding material and are given the first results

  1. Gamma irradiator

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    Fiability of devices set around reactors depends on material resistance under irradiation noticeably joints, insulators, which belongs to composition of technical, safety or physical incasurement devices. The irradiated fuel elements, during their desactivation in a pool, are an interesting gamma irradiation device to simulate damages created in a nuclear environment. The existing facility at Osiris allows to generate an homogeneous rate dose in an important volume. The control of the element distances to irradiation box allows to control this dose rate [fr

  2. 26 CFR 1.166-1 - Bad debts.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Bad debts. 1.166-1 Section 1.166-1 Internal... TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.166-1 Bad debts. (a... shall be allowed in respect of bad debts owed to the taxpayer. For this purpose, bad debts shall...

  3. Preparation and Quality Control of 166-Ho-Boro-Macroaggregates for Radiosynoviorthesis

    Czech Academy of Sciences Publication Activity Database

    Kropáček, Martin; Šrank, Jiří; Mirzajevová, Marcela; Klejzarová, Michaela; Kraft, O.; Kašpárek, R.; Záhlava, J.; Chodacki, A.

    2006-01-01

    Roč. 33, č. 14 (2006), S327-S327 ISSN 1619-7070. [Annual Congress of the European Association of Nuclear Medicine. 30.9.2006-4.10.2006, Athens] R&D Projects: GA AV ČR 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : holmium * radiotherapy Subject RIV: FD - Oncology ; Hematology

  4. Modeling of radiation-induced charge trapping in MOS devices under ionizing irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Petukhov, M. A., E-mail: m.a.petukhov@gmail.com; Ryazanov, A. I. [National Research Center Kurchatov Institute (Russian Federation)

    2016-12-15

    The numerical model of the radiation-induced charge trapping process in the oxide layer of a MOS device under ionizing irradiation is developed; the model includes carrier transport, hole capture by traps in different states, recombination of free electrons and trapped holes, kinetics of hydrogen ions which can be accumulated in the material during transistor manufacture, and accumulation and charging of interface states. Modeling of n-channel MOSFET behavior under 1 MeV photon irradiation is performed. The obtained dose dependences of the threshold voltage shift and its contributions from trapped holes and interface states are in good agreement with experimental data.

  5. Diode-Pumped Thulium (Tm)/Holmium (Ho) Composite Fiber 2.1-Micrometers Laser

    Science.gov (United States)

    2015-09-01

    Schematic of the 800-nm diode pumped Tm/Ho composite fiber laser 8 Under quasi-continuous wave (Q- CW ) pumping conditions of 1-ms duration and a...Fig. 9 (Top) Schematic of the 800-nm diode -pumped Tm/Ho composite fiber laser with outcoupler. (Left) Q- CW laser performance of the Tm/Ho composite...ARL-TR-7452 ● SEP 2015 US Army Research Laboratory Diode -Pumped Thulium (Tm)/Holmium (Ho) Composite Fiber 2.1-μm Laser by G

  6. Successful Treatment of Stent Knot in the Proximal Ureter Using Ureteroscopy and Holmium Laser

    Directory of Open Access Journals (Sweden)

    Masters M. Richards

    2011-01-01

    Full Text Available Knotted ureteral stent is rare yet tedious complication that might represent a treatment challenge to the endourologist. Only twelve cases of knotted stent have been reported. Different management options have been reported, including simple traction, ureteroscopy, percutaneous removal, and open surgery. In this paper, we present the successful untying of the knot using ureteroscopy with holmium laser.

  7. Distribution of microorganisms in medical devices and their inactivation effects by gamma-irradiation

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ishigaki, Isao

    1986-01-01

    Radiation treatment is getting important position for sterilizing medical devices and for packaging films of foods. Recently, survey of bioburden is an important technique for evaluation of sterility doses for medical devices. However, many studies have been done mainly on the irradiation effects of spore-forming bacteria in medical devices. In this study, radiation sensitivity of spore-forming bacteria and fungi were examined after the survey on distribution of microorganisms in several kinds of medical devices. The main contaminant in disposable syringes, needles and conical flasks were consisted of Bacillus, with lesser amount of Micrococcus, Pseudomonas, Peptococcaceae and fungi as positive of 5 - 60 % in the medical devices which cultivated in thioglycolate broth. Bacillus group were identified as B. pumilus, B. sphaericus, B. coagulans, B. megaterium and etc. Fungi were isolated a lesser amounts compared with spore-forming bacteria and identified as Blastomyces, Penicillium, Haplosporangium, Euricoa and Audeobasidium. Peptococaceae were not isolated after irradiation with a dose of 0.1 Mrad even the samples were contaminated with high percentage. The D 10 values of dryed endospores of Bacillus-isolates which attached to the filter paper with pepton-glycerin were obtained to be 0.11 - 0.19 Mrad. The D 10 values of many isolates of fungi in dry condition were obtained below 0.08 Mrad. However, the isolate of Aureobasidium is radiation-resistant, and it's D 10 values was obtained as 0.28 Mrad under aerobic and anaerobic dry condition. (author)

  8. Preparation and quality control of Ho-166 labelled compounds for radiotherapy

    Czech Academy of Sciences Publication Activity Database

    Kropáček, Martin; Melichar, František; Šrank, Jiří; Ventruba, Jiří; Mirzajevová, Marcela; Kraft, O.; Křížová, V.

    2006-01-01

    Roč. 5, č. 1 (2006), S95-S95 ISSN 1450-1147. [Congress of World Federation of Nuclear Medicine and Biology /9./. 22.10.2006-27.10.2006, Seoul] R&D Projects: GA AV ČR 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : holmium * radiotherapy Subject RIV: FD - Oncology ; Hematology

  9. Preparation and Quality Control of 166 Ho-boro -Macroaggregates for radiosynoviorthesis

    Czech Academy of Sciences Publication Activity Database

    Kropáček, Martin; Melichar, František; Šrank, Jiří; Mirzajevová, Marcela; Klejzarová, M.; Kraft, O.; Kasparek, R.; Zahlava, J.; Chodacki, A.

    2006-01-01

    Roč. 33, Supplement 2 (2006), S327-S327 ISSN 1619-7070. [Annual Congress of European Association of Nuclear Medicine. 30.09.2006-04.10.2006, Athens] R&D Projects: GA AV ČR(CZ) 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : holmium * radiotherapy * synoviorthesa Subject RIV: CH - Nuclear ; Quantum Chemistry

  10. Radiolanthanide labeled compounds as radiopharmaceuticals for radio-synoviorthesis

    Czech Academy of Sciences Publication Activity Database

    Melichar, František; Kropáček, Martin; Šrank, Jiří; Mirzajevová, Marcela; Beran, Miloš; Zimová, Jana; Eigner-Henke, Kateřina; Forsterová, Michaela; Kraft, O.

    2007-01-01

    Roč. 6, č. 1 (2007), s. 45-45 ISSN 1450-1147 R&D Projects: GA AV ČR 1QS100480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : radiosynoviorthesis * holmium-166 Subject RIV: FR - Pharmacology ; Medidal Chemistry

  11. 2.05 µm holmium-doped all-fiber laser diode-pumped at 1.125 µm

    Science.gov (United States)

    Kir'yanov, A. V.; Barmenkov, Y. O.; Villegas Garcia, I.

    2017-08-01

    We report a holmium-doped all-fiber laser oscillating at ~2.05 µm in continuous wave at direct in-core pumping by a 1.125 µm laser diode. Two types of home-made holmium-doped alumino-germano-silicate fiber (HDF), differentiated in the Ho3+ doping level, were fabricated to implement the laser, for revealing the effect of Ho3+ concentration upon the laser output. Firstly, the fibers were characterized thoroughly from the material and optical viewpoints. Then, laser action with both HDFs was assessed using the simplest Fabry-Perot cavity, assembled by a couple of spectrally adjusted fiber Bragg gratings, also made-in-house. In the best case, when using the lower-doped HDF of proper length (1.4 m), low threshold (~370 mW) and moderate slope efficiency (~13%) of ~2.05 µm lasing were obtained at 1.125 µm diode pumping. Long-term stability, high brightness, low noise, and purely CW operation are shown to be the laser’s attractive features. Yet, when utilizing the heavier-doped HDF, laser output is revealed to be overall worse, with a possible reason being the deteriorating Ho3+ concentration-related effects.

  12. Production, quality control, biodistribution assessment and preliminary dose evaluation of {sup 166}Ho-alendronate as a bone marrow ablative agent

    Energy Technology Data Exchange (ETDEWEB)

    Fakhari, Ashraf [Tehran University of Medical Sciences (Iran, Islamic Republic of). Dept. of Radiopharmacy; Jalilian, Amir Reza; Yousefnia, Hassan; Zolghadri, Samaneh; Samani, Ali Bahrami; Akbari, Mahmoud Reza; Deha, Fariba Johari [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Shafiee-Ardestani, Mahdi; Khalaj, Ali [Tehran University of Medical Sciences (Iran, Islamic Republic of). Dept. of Medicinal Chemistry

    2015-07-01

    In this study, production, quality control and biodistribution studies of {sup 166}Ho-alendronate have been presented and followed by dosimetric evaluation for human based on biodistribution data in wild-type rats. {sup 166}Ho chloride was obtained by thermal neutron irradiation of natural {sup 165}Ho(NO{sub 3}){sub 3} samples. {sup 166}Ho-alendronate complex was prepared by adding the desired amount of alkaline alendronate solution (0.2 mL, 150 mg/mL) to 3-5 mCi of the {sup 166}HoCl{sub 3} solution. Radiochemical purity of the complex was monitored by instant thin layer chromatography (ITLC). {sup 166}Ho-alendronate complex was prepared in high radiochemical purity (> 99%, ITLC) and specific activity of 4.4 GBq/mmol. Stability studies of the complex in the final preparation and in the presence of human serum were performed up to 48 h. The major accumulation of the radio-complex was in the bone tissues followed by absorbed dose evaluation of each human organ by RADAR software used for modelling the radiation dose delivered. The final preparation was administered to wild-type rats and biodistribution of the complex was performed 2-48 h post injection showing major accumulation of the complex in the bone tissue. The highest absorbed dose for {sup 166}Ho-alendronate is observed in bone surface and red marrow with 2.670 and 1.880 mSv/MBq; respectively. These findings suggest that {sup 166}Ho-alendronate has considerable characteristics compared to {sup 166}Ho-DOTMP and can be a possible candidate for bone marrow ablation in patients with multiple myeloma.

  13. Irradiation device using radiation sources

    International Nuclear Information System (INIS)

    Perraudin, Claude; Amarge, Edmond; Guiho, J.-P.; Horiot, J.-C.; Taniel, Gerard; Viel, Georges; Brethon, J.-P.

    1981-01-01

    The invention refers to an irradiation appliance making use of radioactive sources such as cobalt 60. This invention concerns an irradiation appliance delivering an easily adjustable irradiation beam in accurate dimensions and enabling the radioactive sources to be changed without making use of intricate manipulations at the very place where the appliance has to be used. This kind of appliance is employed in radiotherapy [fr

  14. Therapeutical radiopharmaceuticals based In vivo generator system [166 Dy] Dy/166 Ho

    International Nuclear Information System (INIS)

    Ferro F, G.; Garcia S, L.; Monroy G, F.; Tendilla, J.I.; Pedraza L, M.; Murphy, C.A. de

    2002-01-01

    At the idea to administer to a patient a molecule containing in it structure a father radionuclide, with a half life enough large which allows to the radiolabelled molecule to take up position specifically in a white tissue and decaying In vivo to the daughter radionuclide with properties potentially therapeutic, it is known as In vivo generator system. In this work the preparation and the preliminary dosimetric valuations of radiopharmaceuticals based In vivo generator system 166 Dy Dy/ 166 Ho for applications in radioimmunotherapy, in the treatment of the rheumatoid arthritis and in the bone marrow ablation (m.o.) for candidates patients to bone marrow transplant are presented. (Author)

  15. Safety analysis of an irradiation device for 99Mo production in RA-3 reactor

    International Nuclear Information System (INIS)

    Lerner, Ana Maria; Madariaga, Marcelo; Waldman, Ricardo

    2000-01-01

    The Argentine RA-3 research reactor (5 MW) has been converted to LEU fuel more than nine years ago. Since then, it has been operating with LEU fuel, which has been designed and fabricated at the National Atomic Energy Commission (CNEA). The Nuclear Regulatory Authority (ARN) is the institution in charge of the installation safety control. It is under this framework that the ARN has elaborated a neutronic calculation model for the RA-3 core, paying special attention to the device presently used for the irradiation of (HEU) 235 U targets required to obtain 9 '9Mo as a fission product. A regulatory analysis of results is carried out in the framework of ARN standards for fixed experiments. For such purpose, calculated reactivity values associated with such device are compared with recently measured values at the installation. Finally, and according to guidelines established in the first part of this work, a calculation model for a new device proposed by CNEA for the irradiation of metallic (LEU) uranium targets and still at its design stage, is here analysed. (author)

  16. Measuring device for the distribution of burn-up degree in fuel assembly irradiated in nuclear reactor

    International Nuclear Information System (INIS)

    Kumanomido, Hironori

    1989-01-01

    The object of the invention is to measure the distribution of burn-up degree, of fuel assemblies irradiated in a nuclear reactor in a short time and exactly. That is, the device comprises a device main body having substantially the same length as that for the axial length of a fuel assembly and a detector container disposed axially slidably to the main body. A plurality of radiation detectors are arranged at an equi-axial pitch and contained in the container. The container is caused to slide at a pitch equal to the equi-axial distance of the detectors. In the device having thus been constituted, measurement is conducted at least for twice at an axial position on the side of a fuel assembly irradiated in the nuclear reactor and a position caused to slide therefrom by one pitch. Based on the result, the sensitivities between each of the detectors are compared and the relative sensitivity of the radiation detectors is calibrated. Accordingly, the sensitivity between each of the detectors can be calibrated rapidly and easily. As a result, the distribution of the burn-up degree, etc of irradiated fuel assembly can be measured exactly. (K.M.)

  17. 9 CFR 166.2 - General restrictions.

    Science.gov (United States)

    2010-01-01

    ... of any of the following: Processed products; rendered products; bakery waste; candy waste; eggs... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false General restrictions. 166.2 Section 166.2 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF...

  18. Indoor measurement of photovoltaic device characteristics at varying irradiance, temperature and spectrum for energy rating

    International Nuclear Information System (INIS)

    Bliss, M; Betts, T R; Gottschalg, R

    2010-01-01

    The first three-dimensional performance matrix for use in photovoltaic (PV) energy rating is reported utilizing a novel energy rating solar simulator based on LEDs. Device characteristics are measured indoors at varying irradiance (G), temperature (T) and spectrum (E). This opens the possibility for a more accurate measurement system for energy yield prediction of PV devices, especially for devices with high spectral dependence such as wide bandgap solar cells as they take into account spectral changes in the light. The main aspects of the LED-based solar simulator used are briefly described. A measurement method is developed and detailed in the paper, which takes into account the current imperfections in the achievable spectrum. Measurement results for a crystalline silicon solar cell are used to demonstrate the measurement approach. An uncertainty analysis of the measurement system is given, resulting in an overall absolute uncertainty of 4.3% (coverage factor k = 2) in maximum power measurements at 765 W m −2 irradiance with scope for further improvements

  19. Long-Term Outcomes of Laser Prostatectomy for Storage Symptoms: Comparison of Serial 5-Year Followup Data between High Performance System Photoselective Vaporization and Holmium Laser Enucleation of the Prostate.

    Science.gov (United States)

    Cho, Min Chul; Song, Won Hoon; Park, Juhyun; Cho, Sung Yong; Jeong, Hyeon; Oh, Seung-June; Paick, Jae-Seung; Son, Hwancheol

    2018-01-09

    We compared long-term storage symptom outcomes between photoselective laser vaporization of the prostate with a 120 W high performance system and holmium laser enucleation of the prostate. We also determined factors influencing postoperative improvement of storage symptoms in the long term. Included in our study were 266 men, including 165 treated with prostate photoselective laser vaporization using a 120 W high performance system and 101 treated with holmium laser enucleation of the prostate, on whom 60-month followup data were available. Outcomes were assessed serially 6, 12, 24, 36, 48 and 60 months postoperatively using the International Prostate Symptom Score, uroflowmetry and the serum prostate specific antigen level. Postoperative improvement in storage symptoms was defined as a 50% or greater reduction in the subtotal storage symptom score at each followup visit after surgery compared to baseline. Improvements in frequency, urgency, nocturia, subtotal storage symptom scores and the quality of life index were maintained up to 60 months after photoselective laser vaporization or holmium laser enucleation of the prostate. There was no difference in the degree of improvement in storage symptoms or the percent of patients with postoperative improvement in storage symptoms between the 2 groups throughout the long-term followup. However, the holmium laser group showed greater improvement in voiding symptoms and quality of life than the laser vaporization group. On logistic regression analysis a higher baseline subtotal storage symptom score and a higher BOOI (Bladder Outlet Obstruction Index) were the factors influencing the improvement in storage symptoms 5 years after prostate photoselective laser vaporization or holmium laser enucleation. Our serial followup data suggest that storage symptom improvement was maintained throughout the long-term postoperative period for prostate photoselective laser vaporization with a 120 W high performance system and holmium

  20. Ultra high vacuum fracture and transfer device for AES analysis of irradiated austenitic stainless steel

    International Nuclear Information System (INIS)

    Urie, M.W.; Panayotou, N.F.; Robinson, J.E.

    1980-01-01

    An ultrahigh vacuum fracture and transfer device for analysis of irradiated and non-irradiated SS 316 fuel cladding is described. Mechanical property tests used to study the behavior of cladding during reactor transient over-power conditions are reported. The stress vs temperature curves show minimal differences between unirradiated cladding and unfueled cladding. The fueled cladding fails at a lower temperature. All fueled specimens failed in an intergranular mode

  1. Irradiation of UO2+x fuels in the TANOX device

    International Nuclear Information System (INIS)

    Dehaudt, P.; Caillot, L.; Delette, G.; Eminet, G.; Mocellin, A.

    1998-01-01

    The TANOX analytical irradiation device is presented and the first results concerning stoichiometric and hyper stoichiometric uranium dioxide fuels with two different grain sizes are given. The TANOX device is designed to obtain rapidly significant burnups in fuels at relatively low temperatures. It is placed at the periphery of the SILOE reactor and translated to adjust the irradiation power. The continuous measure of the centre-line temperature allows to control the experiment and to evaluate the thermal behaviour of the rods. A TANOX fuel rod has a length of 100 mm with 20 fuel pellets in a stainless steel cladding and is inserted in a thick aluminium alloy overcladding which is cooled by the primary water circuit reactor. These conditions of small size pellets and improved thermal exchanges have been designed to dissipate the heat power due to fission densities three to five times higher than in a PWR. The first analytical irradiation was devoted to the study of UO 2.00 , UO 2.01 and UO 2.02 fuels with standard and large grain sizes obtained by annealing. A burnup of about 9000 MWd.t -1 U was reached in these fuels. The thermal analysis shows a degraded conductivity for the UO 2.02 fuel rod due to the hyper stoichiometry. The released fractions of 85 Kr during irradiation are negligible as expected (lower than 0,1%). Some of the pellets were heat treated at 1700 deg. C for 5 hours. The gas release was analysed after 30 minutes and at the end of the treatment. The main results are as follows: the fission gas release (FGR) of the standard UO 2 varies from one sample to another; the FGR of the hyper stoichiometric fuels is of the same order of magnitude than that of the stoichiometric UO 2 fuel of normal grain sizes; the grain size increase has no effect on FGR for UO 2.00 but considerably decreases the FGR for UO 2.01 and UO 2.02 fuels. These heat treated samples are also observed to characterize the inter- and intragranular fission gas bubbles. (author)

  2. Lumbar endoscopic percutaneous discolisis, with Holmium YAG laser - four years of experience

    International Nuclear Information System (INIS)

    Ramirez L, Jorge Felipe; Rugeles O, Jose G

    2001-01-01

    we have designed a prospective study over 220 patients with lumbar hernia. our purpose is to show the results that we have obtained with endoscopic percutaneous holmium YAG laser lumbar disc decompression. In all cases, ambulatory surgery was performed using local anesthesia, follow up based on Mac Nab criteria was made with excellent and good results in 75% of patients this is a useful safety outpatient procedure with good results, fewer complications, reduced costs and with the same or better results than traditional procedures

  3. Biodistribution and excretion of radioactivity after the administration of 166Ho-chitosan complex (DW-166HC) into the prostate of rat

    International Nuclear Information System (INIS)

    Seong, Seung Kyoo; Ryu, Jei Man; Bae, Eun Jeong; Shin, Dong Hyuk; Shigematsu, Akiyo; Hatori, Yasuhiko; Nishigaki, Junko; Kwak, Cheol; Lee, Sang Eun; Park, Kyong Bae

    2005-01-01

    The objective of this study was to determine the fate of the 166 Ho-chitosan complex (DW-166HC) in rats by examining its absorption, distribution and excretion after administration into the prostate. About 100 μCi of DW-166HC [containing 0.1875 mg of Ho(NO 3 ) 3 .5H 2 O and 0.25 mg of chitosan] was administered intraprostatically. The level of radioactivity in blood, urinary and faecal excretion, and radioactivity distribution were examined. To determine the effect of chitosan in DW-166HC, 166 Ho nitrate alone [0.1875 mg of Ho(NO 3 ) 3 .5H 2 O] was administered into the prostate of male rats, and radioactivity distribution was examined using whole-body autoradiography. After administration of DW-166HC into the prostate, cumulative urinary and faecal excretion over the period 0-72 h was 0.35% and 0.11%, respectively. The radioactivity at the administration site was extremely high at all time points up to 144 h (>98% of injected dose). The small amount of radioactivity which did transfer from the administration site distributed mainly to the liver, spleen, kidney cortex and bone. Compared with the DW-166HC group, the group that received 166 Ho nitrate alone displayed three- to fourfold higher levels of radioactivity in the main tissues, including liver, spleen, kidney cortex and bone, at 24 h after administration (P<0.05). (orig.)

  4. Neutron activation of microspheres containing 165Ho: theoretical and experimental radionuclidic impurities study

    International Nuclear Information System (INIS)

    Squair, Peterson L.; Pozzo, Lorena; Ivanov, Evandro; Osso Junior, Joao A.

    2011-01-01

    The 166 Ho microspheres are potentially interesting for medical applications for treatment of many tumors. The internal radionuclide therapy can use polymer or glass device that provides structural support for the radionuclide. After activation, beta minus emission of 166 Ho (T 1/2 =26.8h, β - E max =1.84 MeV, γ E p =80.6 keV) can be used for therapeutic purposes. The aim of this work is study the influence of radionuclide impurities between End of Bombardment (EOB) and the medical application. The appropriate specific activities and purity along decay should be adequate for their safe and efficient medical applications. The good practices on neutron activation techniques are choice a high purity target to avoid production of undesirable radionuclides and when possible with enriched targets to obtain higher specific activity. In this work the target used was Ho 2 O 3 and polymeric microspheres containing holmium acetylacetonate (HoAcAc) manufactured at the Biotechnology Center-IPEN/CNEN-SP. Three conditions were evaluated: preliminary test with 1.0x10 13 n.cm -2 s -1 for 1.0 hour; nowadays maximum capability of IEA-R1 reactor with 5.0x10 13 n.cm -2 s -1 for 64.0 hours and the ideal IEA-R1 operation with 5.0x10 13 n.cm -2 s -1 for 120.0 hours. Considering the sample with 99.9% 165 Ho purity and 0.1% for each impurities elements with its natural abundance, the highest radionuclidic impurity is the Lutetium followed by Ytterbium, Lanthanum and Cerium. The intrinsic radionuclidic impurity of 166 mHo is less relevant. This review is important to identify the radionuclidic purity characteristics of the preliminary studies with different time and flux irradiation. The data produced in this paper will help to define strategies for the production of 166 Ho radioisotope at IEA-R1 IPEN/CNEN-SP reactor. (author)

  5. Ablation of intervertebral discs in dogs using a MicroJet-assisted dye-enhanced injection device coupled with the diode laser

    Science.gov (United States)

    Bartels, Kenneth E.; Henry, George A.; Dickey, D. Thomas; Stair, Ernest L.; Powell, Ronald; Schafer, Steven A.; Nordquist, Robert E.; Frederickson, Christopher J.; Hayes, Donald J.; Wallace, David B.

    1998-07-01

    Use of holmium laser energy for vaporization/coagulation of the nucleus pulposus in canine intervertebral discs has been previously reported and is currently being applied clinically in veterinary medicine. The procedure was originally developed in the canine model and intended for potential human use. Since the pulsed (15 Hz) holmium laser energy exerts photomechanical and photothermal effects, the potential for extrusion of additional disc material to the detriment of the patient is possible using the procedure developed for the dog. To reduce this potential complication, use of diode laser (805 nm - CW mode) energy, coupled with indocyanine green (ICG) as a selective laser energy absorber, was formulated as a possible alternative. Delivery of the ICG and diode laser energy was through a MicroJet device that could dispense dye interactively between individual laser 'shots.' Results have shown that it is possible to selectively ablate nucleus pulposus in the canine model using the device described. Acute observations (gross and histopathologic) illustrate that accurate placement of the spinal needle before introduction of the MicroJet device is critically dependent on the expertise of the interventional radiologist. In addition, the success of the overall technique depends on consistent delivery of both ICG and diode laser energy. Minimizing tissue carbonization on the tip of the MicroJet device is also of crucial importance for effective application of the technique in clinical veterinary medicine.

  6. 12 CFR 16.6 - Sales of nonconvertible debt.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Sales of nonconvertible debt. 16.6 Section 16.6... RULES § 16.6 Sales of nonconvertible debt. (a) The OCC will deem offers or sales of bank issued... grade; (5) Prior to or simultaneously with the sale of the debt, each purchaser receives an offering...

  7. Drilling Experiments of Dummy Fuel Rods Using a Mock-up Drilling Device and Detail Design of Device for Drilling of Irradiated Nuclear Fuel Rods

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Yong; Lee, H. K.; Chun, Y. B.; Park, S. J.; Kim, B. G

    2007-07-15

    KAERI are developing the safety evaluation method and the analysis technology for high burn-up nuclear fuel rod that is the project, re-irradiation for re-instrumented fuel rod. That project includes insertion of a thermocouple in the center hole of PWR nuclear fuel rod with standard burn-up, 3,500{approx}4,000MWD/tU and then inspection of the nuclear fuel rod's heat performance during re-irradiation. To re-fabricate fuel rod, two devices are needed such as a drilling machine and a welding machine. The drilling machine performs grinding a center hole, 2.5 mm in diameter and 50 mm in depth, for inserting a thermocouple. And the welding machine is used to fasten a end plug on a fuel rod. Because these two equipment handle irradiated fuel rods, they are operated in hot cell blocked radioactive rays. Before inserting any device into hot cell, many tests with that machine have to be conducted. This report shows preliminary experiments for drilling a center hole on dummy of fuel rods and optimized drilling parameters to lessen operation time and damage of diamond dills. And the design method of a drilling machine for irradiated nuclear fuel rods and detail design drawings are attached.

  8. Therapeutical radiopharmaceuticals based In vivo generator system [{sup 166} Dy] Dy/{sup 166} Ho; Radiofarmacos terapeuticos basados en un sistema de generador In vivo [{sup 166}Dy] Dy/{sup 166}Ho

    Energy Technology Data Exchange (ETDEWEB)

    Ferro F, G.; Garcia S, L.; Monroy G, F.; Tendilla, J.I. [Gerencia de Aplicaciones Nucleares en la Salud, ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Pedraza L, M.; Murphy, C.A. de [Departamento de Medicina Nuclear, Instituto Nacional de Pediatria, Mexico D.F. (Mexico)

    2002-07-01

    At the idea to administer to a patient a molecule containing in it structure a father radionuclide, with a half life enough large which allows to the radiolabelled molecule to take up position specifically in a white tissue and decaying In vivo to the daughter radionuclide with properties potentially therapeutic, it is known as In vivo generator system. In this work the preparation and the preliminary dosimetric valuations of radiopharmaceuticals based In vivo generator system {sup 166} Dy Dy/{sup 166} Ho for applications in radioimmunotherapy, in the treatment of the rheumatoid arthritis and in the bone marrow ablation (m.o.) for candidates patients to bone marrow transplant are presented. (Author)

  9. Alternative Treatment of Osteoma Using an Endoscopic Holmium-YAG Laser

    Directory of Open Access Journals (Sweden)

    Ba Leun Han

    2012-07-01

    Full Text Available Osteoma is one of the most common tumors of the cranial vault and the facial skeleton. For osteoma in the facial region, endoscopic resection is widely used to prevent surgical scarring. Tumors in a total of 14 patients were resected using an endoscopic holmium-doped yttrium aluminium garnet (Ho:YAG laser with a long flexible fiber. Aside from having the advantage of not leaving a scar due to the use of endoscopy, this procedure allowed resection at any position, was minimally invasive, and caused less postoperative pain. This method yielded excellent cosmetic results, so the endoscopic Ho:YAG laser is expected to emerge as a good treatment option for osteoma.

  10. Charge yield for cobalt-60 and 10-keV x-ray irradiations of MOS devices

    International Nuclear Information System (INIS)

    Shaneyfelt, M.R.; Fleetwood, D.M.; Schwank, J.R.; Hughes, K.L.

    1991-01-01

    In this paper the radiation response of MOS devices exposed to 60 Co and low-energy (∼10 keV) x-ray irradiation is evaluated as a function of electric field during exposure. Improved charge yield estimates are obtained for 60 Co irradiations at fields below 1 MV/cm by matching voltage shifts due to oxide-trap and interface-trap charge to an E -0.55 electric field dependence. Combining these improved charge yield estimates and calculated dose enhancement factors, the relative response of x-ray to 60 Co irradiations is accurately predicted for oxide electric fields from 0.03 MV/cm to 5.0 MV/cm. The ability to predict the relative response of x-ray to 60 Co irradiations should speed acceptance of x-ray testers as a hardness assurance tool

  11. Recovery of damage in rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays

    Science.gov (United States)

    Brucker, G. J.; Van Gunten, O.; Stassinopoulos, E. G.; Shapiro, P.; August, L. S.; Jordan, T. M.

    1983-01-01

    This paper reports on the recovery properties of rad-hard MOS devices during and after irradiation by electrons, protons, alphas, and gamma rays. The results indicated that complex recovery properties controlled the damage sensitivities of the tested parts. The results also indicated that damage sensitivities depended on dose rate, total dose, supply bias, gate bias, transistor type, radiation source, and particle energy. The complex nature of these dependencies make interpretation of LSI device performance in space (exposure to entire electron and proton spectra) difficult, if not impossible, without respective ground tests and analyses. Complete recovery of n-channel shifts was observed, in some cases within hours after irradiation, with equilibrium values of threshold voltages greater than their pre-irradiation values. This effect depended on total dose, radiation source, and gate bias during exposure. In contrast, the p-channel shifts recovered only 20 percent within 30 days after irradiation.

  12. Acute effects of pulsed-laser irradiation on the arterial wall

    Science.gov (United States)

    Nakamura, Fumitaka; Kvasnicka, Jan; Lu, Hanjiang; Geschwind, Herbert J.; Levame, Micheline; Bousbaa, Hassan; Lange, Francoise

    1992-08-01

    Pulsed laser coronary angioplasty with an excimer or a holmium-yttrium-aluminum-garnet (Ho:YAG) laser may become an alternative treatment for patients with coronary artery disease. However, little is known about its acute consequences on the normal arterial wall. This study was designed to examine the acute histologic consequences of these two pulsed lasers on the arterial wall of normal iliac arteries in rabbits. Irradiation with each laser was performed in 15 normal iliac sites on eight male New Zealand white rabbits. The excimer laser was operated at 308 nm, 25 Hz, 50 mJ/mm2/pulse, and 135 nsec/pulse and the Ho:YAG laser was operated at 2.1 micrometers , 3/5 Hz, 400 mJ/pulse, and 250 microsecond(s) ec/pulse. The excimer and Ho:YAG laser were coupled into a multifiber wire-guided catheter of 1.4 and 1.5 mm diameter, respectively. The sites irradiated with excimer or Ho:YAG laser had the same kinds of histologic features, consisting of exfoliation of the endothelium, disorganization of internal elastic lamina, localized necrosis of vascular smooth muscle cells, and fissures in the medial layer. However, the sites irradiated with excimer laser had lower grading scores than those irradiated with Ho:YAG laser (p vascular injury.

  13. Structure and composition of enamel and dentin after thermal treatment or infrared laser irradiation

    International Nuclear Information System (INIS)

    Bachmann, Luciano

    2004-01-01

    The main purpose of this work is to identify the crystallographic structure, optical properties, chemical composition and electron paramagnetic signals that laser irradiation or oven heating produces on the tissue. The thermal treatment was conducted in oven with temperature range below 1000 deg C and the laser irradiation with holmium (Ho:YLF - 2,065 μm) and erbium (Er:YAG - 2,94 μm) laser. The tissue characterization was carried out with X-ray diffraction, scanning electron microscopy, ultraviolet and visible transmission spectroscopy, light microscopy, infrared transmission/reflection spectroscopy and electron paramagnetic resonance. The holmium irradiated enamel (600-800 J/cm 2 ) shows the presence of tetracalcium phosphate that coexists with the natural phase (hydroxyapatite). The irradiated dentin shows only the sharper diffraction peaks of the natural phase. The narrows peaks, observed after irradiation, could be assigned to the dentin crystal growth and impurities elimination. Tissue discoloration is observed after thermal treatment with temperatures above 100 deg C. Heated enamel become white-opaque and the origin is assigned to the water elimination, which promotes higher light scattering by the prismatic structure. On the other hand, heated dentin, with similar temperatures becomes brown. The dentin browning changes with the temperature and shown two peaks, at 375 deg C and 700 deg C. The peak at 375 deg C is assigned to the collagen structure degradation and at 700 deg C to the cyanate formation. The dentin discoloration produced with temperatures below 200 deg C is reversible after the tissue hydration. Both enamel and dentin discoloration are also observed in erbium irradiated tissues. Thermal treatments, heating in oven or laser irradiation, change mainly the organic matrix composition and water present in the tissues. The inorganic matrix is more stable and its radicals are changed, with more predominance, only at temperatures higher than 500 deg

  14. High power operation of cladding pumped holmium-doped silica fibre lasers.

    Science.gov (United States)

    Hemming, Alexander; Bennetts, Shayne; Simakov, Nikita; Davidson, Alan; Haub, John; Carter, Adrian

    2013-02-25

    We report the highest power operation of a resonantly cladding-pumped, holmium-doped silica fibre laser. The cladding pumped all-glass fibre utilises a fluorine doped glass layer to provide low loss cladding guidance of the 1.95 µm pump radiation. The operation of both single mode and large-mode area fibre lasers was demonstrated, with up to 140 W of output power achieved. A slope efficiency of 59% versus launched pump power was demonstrated. The free running emission was measured to be 2.12-2.15 µm demonstrating the potential of this architecture to address the long wavelength operation of silica based fibre lasers with high efficiency.

  15. Device intended for measurement of induced trapped charge in insulating materials under electron irradiation in a scanning electron microscope

    International Nuclear Information System (INIS)

    Belkorissat, R; Benramdane, N; Jbara, O; Rondot, S; Hadjadj, A; Belhaj, M

    2013-01-01

    A device for simultaneously measuring two currents (i.e. leakage and displacement currents) induced in insulating materials under electron irradiation has been built. The device, suitably mounted on the sample holder of a scanning electron microscope (SEM), allows a wider investigation of charging and discharging phenomena that take place in any type of insulator during its electron irradiation and to determine accurately the corresponding time constants. The measurement of displacement current is based on the principle of the image charge due to the electrostatic influence phenomena. We are reporting the basic concept and test results of the device that we have built using, among others, the finite element method for its calibration. This last method takes into account the specimen chamber geometry, the geometry of the device and the physical properties of the sample. In order to show the possibilities of the designed device, various applications under different experimental conditions are explored. (paper)

  16. Impact of Room Location on UV-C Irradiance and UV-C Dosage and Antimicrobial Effect Delivered by a Mobile UV-C Light Device.

    Science.gov (United States)

    Boyce, John M; Farrel, Patricia A; Towle, Dana; Fekieta, Renee; Aniskiewicz, Michael

    2016-06-01

    OBJECTIVE To evaluate ultraviolet C (UV-C) irradiance, UV-C dosage, and antimicrobial effect achieved by a mobile continuous UV-C device. DESIGN Prospective observational study. METHODS We used 6 UV light sensors to determine UV-C irradiance (W/cm2) and UV-C dosage (µWsec/cm2) at various distances from and orientations relative to the UV-C device during 5-minute and 15-minute cycles in an ICU room and a surgical ward room. In both rooms, stainless-steel disks inoculated with methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), and Clostridium difficile spores were placed next to sensors, and UV-C dosages and log10 reductions of target organisms achieved during 5-minute and 15-minute cycles were determined. Mean irradiance and dosage readings were compared using ANOVA. RESULTS Mean UV-C irradiance was nearly 1.0E-03 W/cm2 in direct sight at a distance of 1.3 m (4 ft) from the device but was 1.12E-05 W/cm2 on a horizontal surface in a shaded area 3.3 m (10 ft) from the device (P4 to 1-3 for MRSA, >4 to 1-2 for VRE and >4 to 0 log10 for C. difficile spores, depending on the distance from, and orientation relative to, the device with 5-minute and 15-minute cycles. CONCLUSION UV-C irradiance, dosage, and antimicrobial effect received from a mobile UV-C device varied substantially based on location in a room relative to the UV-C device. Infect Control Hosp Epidemiol 2016;37:667-672.

  17. 9 CFR 166.14 - Cleaning and disinfecting.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Cleaning and disinfecting. 166.14... AGRICULTURE SWINE HEALTH PROTECTION SWINE HEALTH PROTECTION General Provisions § 166.14 Cleaning and disinfecting. (a) Disinfectants to be used. Disinfection required under the regulations in this Part shall be...

  18. 26 CFR 1.166-4 - Reserve for bad debts.

    Science.gov (United States)

    2010-04-01

    ... the bad debts reserves of certain mutual savings banks, domestic building and loan associations, and... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Reserve for bad debts. 1.166-4 Section 1.166-4...) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.166-4 Reserve for bad...

  19. Outcome analysis of holmium laser and pneumatic lithotripsy in the endoscopic management of lower ureteric calculus in pediatric patients: a prospective study

    Directory of Open Access Journals (Sweden)

    Ankur Jhanwar

    Full Text Available ABSTRACT Objective: To analyse outcomes of holmium laser and pneumatic lithotripsy in treatment of lower ureteric calculus in pediatric patients. Materials and methods: Prospective study conducted between August 2013 and July 2015. Inclusion criteria were lower ureteric calculus with stone size ≤1.5cms. Exclusion criteria were other than lower ureteric calculus, stone size ≥1.5cms, congenital renal anomalies, previous ureteral stone surgery. Patients were divided into two groups. Group A underwent pneumatic and group B underwent laser lithotripsy procedure. Patient's baseline demographic and peri-operative data were recorded and analysed. Post operatively X-ray/ultrasound KUB (Kidney, ureter and bladder was performed to assess stone free status. Results: A total of 76 patients who met the inclusion criteria to ureteroscopic intracorporeal lithotripsy were included. Group A and B included 38 patients in each. Mean age was 12.5±2.49 in Group A and 11.97±2.74 years in Group B respectively (p=0.38. Overall success rate was 94.73% in Group A and 100% in Group B, respectively (p=0.87. Conclusion: Holmium Laser lithotripsy is as efficacious as pneumatic lithotripsy and can be used safely for the endoscopic management of lower ureteric calculus in pediatric patients. However, holmium laser requires more expertise and it is a costly alternative.

  20. Laser-based irradiation apparatus and method to measure the functional dose-rate response of semiconductor devices

    Science.gov (United States)

    Horn, Kevin M [Albuquerque, NM

    2008-05-20

    A broad-beam laser irradiation apparatus can measure the parametric or functional response of a semiconductor device to exposure to dose-rate equivalent infrared laser light. Comparisons of dose-rate response from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems can determine if aging has affected the device's overall functionality. The dependence of these changes on equivalent dose-rate pulse intensity and/or duration can be measured with the apparatus. The synchronized introduction of external electrical transients into the device under test can be used to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure while exposing the device to dose-rate equivalent infrared laser light.

  1. Robotic Assisted Simple Prostatectomy versus Holmium Laser Enucleation of the Prostate for Lower Urinary Tract Symptoms in Patients with Large Volume Prostate: A Comparative Analysis from a High Volume Center.

    Science.gov (United States)

    Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre

    2017-04-01

    We report a comparative analysis of robotic assisted simple prostatectomy vs holmium laser enucleation of the prostate in patients who had benign prostatic hyperplasia with a large volume prostate (greater than 100 ml). A total of 81 patients underwent robotic assisted simple prostatectomy and 45 underwent holmium laser enucleation of the prostate in a 7-year period. Patients were preoperatively assessed with transrectal ultrasound and uroflowmetry. Functional parameters were assessed postoperatively during followup. Perioperative outcomes included operative time, postoperative hemoglobin, catheterization time and hospitalization. Complications were reported according to the Clavien-Dindo classification. Compared to the holmium laser enucleation group, patients treated with prostatectomy were significantly younger (median age 69 vs 74 years, p = 0.032) and less healthy (Charlson comorbidity index 2 or greater in 62% vs 29%, p = 0.0003), and had a lower rate of suprapubic catheterization (23% vs 42%, p = 0.028) and a higher preoperative I-PSS (International Prostate Symptom Score) (25 vs 21, p = 0.049). Both groups showed an improvement in the maximum flow rate (15 vs 11 ml per second, p = 0.7), and a significant reduction in post-void residual urine (-73 vs -100 ml, p = 0.4) and I-PSS (-20 vs -18, p = 0.8). Median operative time (105 vs 105 minutes, p = 0.9) and postoperative hemoglobin (13.2 vs 13.8 gm/dl, p = 0.08) were similar for robotic assisted prostatectomy and holmium laser enucleation, respectively. Median catheterization time (3 vs 2 days, p = 0.005) and median hospitalization (4 vs 2 days, p = 0.0001) were slightly shorter in the holmium laser group. Complication rates were similar with no Clavien grade greater than 3 in either group. Our results from a single center suggest comparable outcomes for robotic assisted simple prostatectomy and holmium laser enucleation of the prostate in patients with a large volume prostate. These findings require

  2. 27 CFR 24.166 - Buildings or rooms.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Buildings or rooms. 24.166... OF THE TREASURY LIQUORS WINE Construction and Equipment § 24.166 Buildings or rooms. All buildings or... afford adequate protection to the revenue. Each building or room will be constructed of substantial...

  3. 40 CFR 166.7 - User notification; advertising.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false User notification; advertising. 166.7... § 166.7 User notification; advertising. (a) A State or Federal agency that obtains an exemption may... received) delivers or offers to deliver any pesticide, to advertise the pesticide for any use authorized by...

  4. A primary exploration to quasi-two-dimensional rare-earth ferromagnetic particles: holmium-doped MoS2 sheet as room-temperature magnetic semiconductor

    Science.gov (United States)

    Chen, Xi; Lin, Zheng-Zhe

    2018-05-01

    Recently, two-dimensional materials and nanoparticles with robust ferromagnetism are even of great interest to explore basic physics in nanoscale spintronics. More importantly, room-temperature magnetic semiconducting materials with high Curie temperature is essential for developing next-generation spintronic and quantum computing devices. Here, we develop a theoretical model on the basis of density functional theory calculations and the Ruderman-Kittel-Kasuya-Yoshida theory to predict the thermal stability of two-dimensional magnetic materials. Compared with other rare-earth (dysprosium (Dy) and erbium (Er)) and 3 d (copper (Cu)) impurities, holmium-doped (Ho-doped) single-layer 1H-MoS2 is proposed as promising semiconductor with robust magnetism. The calculations at the level of hybrid HSE06 functional predict a Curie temperature much higher than room temperature. Ho-doped MoS2 sheet possesses fully spin-polarized valence and conduction bands, which is a prerequisite for flexible spintronic applications.

  5. HOLMIUM LASER ENUCLEATION OF THE PROSTATE, FEATURES OF THE INTERVENTION

    Directory of Open Access Journals (Sweden)

    O. Y. Hublarov

    2014-01-01

    Full Text Available Holmium laser enucleation of the prostate (HoLEP is a minimally invasive procedure used for the treatment of benign prostatic hyperplasia. The method is as reliable performance with long-term monitoring, and high safety compared to conventional methods of surgical treatment of prostatic hyperplasia – suprapubic simple prostatectomy and transurethral resection of the prostate. Despite the complexity and duration of training for mastering HoLEP currently has a definite Frortage of references detailing the technical aspects of the method. The proposed article is detailed recommendations skilled mastering HoLEP. The material is based on a review of existing literature and my own experience and clinical material Latgale Urology Center in the development and conduct of HoLEP. 

  6. Evidence for a devil's staircase in holmium produced by an applied magnetic field

    International Nuclear Information System (INIS)

    Cowley, R.A.; Jehan, D.A.; McMorrow, D.F.; McIntyre, G.J.

    1991-01-01

    The magnetic structure of holmium has been studied using neutron diffraction when a magnetic field is applied along the c axis. The field has the effect of suppressing the onset of the commensurate cone phase found at low temperatures in zero field, and instead produces a series of spin-slip structures. In contrast to the zero-field diffraction experiments, where a continuous variation of the magnetic wave vector q was observed, we find that below ∼15 K the wave vector q is always commensurate and forms a devil's staircase with increasing field

  7. The effect and influence of lumen holmium laser lithotripsy on serum oxidative stress proteins and inflammatory factors of ureteral calculi patients

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    2016-09-01

    Full Text Available Objective: To investigate the effect and influence of lumen holmium laser lithotripsy on treating serum oxidative stress proteins and inflammatory factors of patients with ureteral calculi. Methods: A total of 120 cases of patients with ureteral calculi treated in our hospital from May 2010 to Nov 2014 were enrolled in this research for an analysis study. The effect and influence on serum oxidative stress proteins and inflammatory factors of lumen holmium laser lithotripsy on ureteral calculi patients were assayed. Then 120 cases of healthy subjects in our hospital at the same period were taken as control. Results: Among the 120 cases of ureteral calculi patients, 113 cases of patients showed successful operation, with a success rate of 94.2%. The average calculi-discharged time was (28.4 ± 11.2 d and the average operation time was (58.9 ± 10.7 min, while the postoperative hospital stay is (3.8 ± 1.2 d. The results also showed that the levels of NOX1. NOX3, NOX4 and NOX5, and levels of interleukin-2 (IL-2, IL-6, IL-10 and TNF-α of patients with ureteral calculi were significantly higher, compared with the control group, and these parameters were normalized greatly after operation with that the levels of them were significantly different from those before operation. Conclusion: Lumen holmium laser lithotripsy exerts a significant effect on ureteral calculi patients and the oxidative stress parameters and inflammatory factor were normalized greatly.

  8. Synchrotron X-ray irradiation effects on the device characteristics and the resistance to hot-carrier damage of MOSFETs with 4 nm thick gate oxides

    International Nuclear Information System (INIS)

    Tanaka, Yuusuke; Tanabe, Akira; Suzuki, Katsumi

    1998-01-01

    The effects of synchrotron x-ray irradiation on the device characteristics and hot-carrier resistance of n- and p-channel metal oxide semiconductor field effect transistors (MOSFETs) with 4 nm thick gate oxides are investigated. In p-channel MOSFETs, device characteristics were significantly affected by the x-ray irradiation but completely recovered after annealing, while the device characteristics in n-channel MOSFETs were not noticeably affected by the irradiation. This difference appears to be due to a difference in interface-state generation. In p-channel MOSFETs, defects caused by boron-ion penetration through the gate oxides may be sensitive to x-ray irradiation, causing the generation of many interface states. These interface states are completely eliminated after annealing in hydrogen gas. The effects of irradiation on the resistance to hot-carrier degradation in annealed 4 nm thick gate-oxide MOSFETs were negligible even at an x-ray dose of 6,000 mJ/cm 2

  9. Use of the Stone Cone for prevention of calculus retropulsion during holmium:YAG laser lithotripsy: case series and review of the literature.

    Science.gov (United States)

    Eisner, Brian H; Dretler, Stephen P

    2009-01-01

    Stone retropulsion during ureteroscopic lithotripsy leads to additional procedures for residual calculi. The Stone Cone (Boston Scientific, Natick, Mass., USA) is a device designed to prevent stone migration. To determine the incidence of calculus retropulsion and additional procedures after ureteroscopy with intracorporeal lithotripsy while using the Stone Cone. A retrospective review of patients with obstructing ureteral calculi who underwent ureteroscopy and holmium:YAG laser lithotripsy using the Stone Cone as a backstop over a 3-year period at an academic medical center was performed. 133 patients underwent ureteroscopy with holmium:YAG laser lithotripsy using the Stone Cone to prevent calculus retroplusion. Success was defined as no residual fragments >2 mm in size, no changes from semirigid to flexible ureteroscope, and no additional procedures. Post-operative imaging was abdominal plain radiography or computed tomography. A MEDLINE search was performed to indentify all English clinical studies of the Stone Cone. Of the 133 uses of the Stone Cone, there were 2 (1.5%) residual retropulsed fragments >2 mm which required an additional procedure. There were no changes to flexible ureteroscope secondary to stone retropulsion in 105 cases of semirigid ureteroscopy. There was no instance of ureteral obstruction from residual 2-mm fragments. There were no ureteral strictures or hydronephrosis among 91 patients with long-term follow-up imaging. A review of the literature was performed which yielded 4 clinical publications and 90 reported cases using the Stone Cone with 100% success. Two of these studies showed statistically significant improvement when compared with control patients. The Stone Cone minimized stone retropulsion during ureteroscopic laser lithotripsy. The Stone Cone offers the urologist greater certainty during ureteroscopy and may decrease the number of clinically significant residual calculi. Copyright 2009 S. Karger AG, Basel.

  10. Band to Band Tunneling (BBT) Induced Leakage Current Enhancement in Irradiated Fully Depleted SOI Devices

    Science.gov (United States)

    Adell, Phillipe C.; Barnaby, H. J.; Schrimpf, R. D.; Vermeire, B.

    2007-01-01

    We propose a model, validated with simulations, describing how band-to-band tunneling (BBT) affects the leakage current degradation in some irradiated fully-depleted SOI devices. The dependence of drain current on gate voltage, including the apparent transition to a high current regime is explained.

  11. Holmium-doped fluorotellurite microstructured fibers for 2.1 μm lasing.

    Science.gov (United States)

    Yao, Chuanfei; He, Chunfeng; Jia, Zhixu; Wang, Shunbin; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping

    2015-10-15

    Holmium (Ho3+)-doped fluorotellurite microstructured fibers based on TeO2-BaF2-Y2O3 glasses are fabricated by using a rod-in-tube method. By using a 1.992 μm fiber laser as the pump source, lasing at 2.077 μm is obtained from a 27 cm long Ho3+-doped fluorotellurite microstructured fiber. The maximum unsaturated power is about 161 mW and the corresponding slope efficiency is up to 67.4%. The influence of fiber length on lasing at 2.1 μm is also investigated. Our results show that Ho3+-doped fluorotellurite microstructured fibers are promising gain media for 2.1 μm laser applications.

  12. Gemstone dedicated gamma irradiation development

    Energy Technology Data Exchange (ETDEWEB)

    Omi, Nelson M.; Rela, Paulo R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mails: nminoru@ipen.br; prela@ipen.br

    2007-07-01

    The gemstones gamma irradiation process to enhance the color is widely accepted for the jewelry industry. These gems are processed in conventional industrial gamma irradiation plant which are optimized for other purposes, using underwater irradiation devices with high rejection rate due to its poor dose uniformity. A new conception design, which states the working principles and manufacturing ways of the device, was developed in this work. The suggested device's design is based on the rotation of cylindrical baskets and their translation in circular paths inside and outside a cylindrical source rack as a planetary system. The device is meant to perform the irradiation in the bottom of the source storage pool, where the sources remain always shielded by the water layer. The irradiator matches the Category III IAEA classification. To verify the physical viability of the basic principle, tests with rotating cylindrical baskets were performed in the Multipurpose Irradiator constructed in the CTR, IPEN. Also, simulations using the CADGAMMA software, adapted to simulate underwater irradiations, were performed. With the definitive optimized irradiator, the irradiation quality will be enhanced with better dose control and the production costs will be significantly lower than market prices due to the intended treatment device's optimization. This work presents some optimization parameters and the expected performance of the irradiator. (author)

  13. Percutaneous Transhepatic Endoscopic Holmium Laser Lithotripsy for Intrahepatic and Choledochal Biliary Stones

    International Nuclear Information System (INIS)

    Rimon, Uri; Kleinmann, Nir; Bensaid, Paul; Golan, Gil; Garniek, Alexander; Khaitovich, Boris; Winkler, Harry

    2011-01-01

    Purpose: To report our approach for treating complicated biliary calculi by percutaneous transhepatic endoscopic biliary holmium laser lithotripsy (PTBL). Patients and Methods: Twenty-two symptomatic patients (11 men and 11 women, age range 51 to 88 years) with intrahepatic or common bile duct calculi underwent PTBL. Nine patients had undergone previous gastrectomy and small-bowel anastomosis, thus precluding endoscopic retrograde cholangiopancreatography. In the other 13 patients, stone removal attempts by ERCP failed due to failed access or very large calculi. We used a 7.5F flexible ureteroscope and a 200-μm holmium laser fiber by way of a percutaneous transhepatic tract, with graded fluoroscopy, to fragment the calculi with direct vision. Balloon dilatation was added when a stricture was seen. The procedure was performed with the patient under general anaesthesia. A biliary drainage tube was left at the end of the procedure. Results: All stones were completely fragmented and flushed into the small bowel under direct vision except for one patient in whom the procedure was aborted. In 18 patients, 1 session sufficed, and in 3 patients, 2 sessions were needed. In 7 patients, balloon dilatation was performed for benign stricture after Whipple operation (n = 3), for choledochalenteric anastomosis (n = 3), and for recurrent cholangitis (n = 1). Adjunctive “balloon push” (n = 4) and “rendezvous” (n = 1) procedures were needed to completely clean the biliary tree. None of these patients needed surgery. Conclusion: Complicated or large biliary calculi can be treated successfully using PTBL. We suggest that this approach should become the first choice of treatment before laparoscopic or open surgery is considered.

  14. A new device for X-ray Diffraction analyses of irradiated materials

    International Nuclear Information System (INIS)

    Valot, Christophe; Blay, Thierry; Caillot, Laurent; Ferroud-Plattet, Marie Pierre

    2008-01-01

    A new X-Ray Diffraction (XRD) equipment is being implemented in the LECA (Cea - Cadarache) hot laboratory. The device will be dedicated to structural characterization on irradiated fuels, as PWR fuels, transmutation targets and innovative fuels. The paper will present the specific design that was decided in order to reduce the number of components in contaminated volume and to make servicing easier. The analytical performances of this new equipment will be illustrated on some model samples: -) micro-diffraction capabilities will be detailed on heterogeneous material; -) strain and stress analyses on fresh uranium oxide pellets. (authors)

  15. Hyperfine structure investigations for the odd-parity configuration system in atomic holmium

    Science.gov (United States)

    Stefanska, D.; Furmann, B.

    2018-02-01

    In this work new experimental results of the hyperfine structure (hfs) in the holmium atom are reported, concerning the odd-parity level system. Investigations were performed by the method of laser induced fluorescence in a hollow cathode discharge lamp on 97 spectral lines in the visible part of the spectrum. Hyperfine structure constants: magnetic dipole - A and electric quadrupole - B for 40 levels were determined for the first time; for another 21 levels the hfs constants available in the literature were remeasured. Results for the A constants can be viewed as fully reliable; for B constants further possibilities of improving the accuracy are considered.

  16. Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device

    Energy Technology Data Exchange (ETDEWEB)

    Zarghami, Niloufar, E-mail: nzargham@uwo.ca; Jensen, Michael D. [Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Talluri, Srikanth; Dick, Frederick A. [Department of Biochemistry, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); London Regional Cancer Program, London Health Sciences Centre, 800 Commissioners Road East, London, Ontario N6A 5W9 (Canada); Foster, Paula J. [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8 (Canada); Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Chambers, Ann F. [Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); London Regional Cancer Program, London Health Sciences Centre, 800 Commissioners Road East, London, Ontario N6A 5W9 (Canada); Wong, Eugene [Department of Physics and Astronomy, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Medical Biophysics, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); Department of Oncology, The University of Western Ontario, 1151 Richmond Street, London, Ontario N6A 3K7 (Canada); London Regional Cancer Program, London Health Sciences Centre, 800 Commissioners Road East, London, Ontario N6A 5W9 (Canada)

    2015-11-15

    Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.

  17. Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device

    International Nuclear Information System (INIS)

    Zarghami, Niloufar; Jensen, Michael D.; Talluri, Srikanth; Dick, Frederick A.; Foster, Paula J.; Chambers, Ann F.; Wong, Eugene

    2015-01-01

    Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs

  18. Holmium laser assisted ′anatomical′ enucleation of adenoma of benign hyperplasia of prostate

    Directory of Open Access Journals (Sweden)

    Shivadeo S Bapat

    2006-01-01

    Full Text Available Aims: To present our technique of Holmium Laser assisted "ANATOMICAL" enucleation of the benign prostatic adenoma (HoLEP in 219 patients. Procedure is based on the principle of digital enucleation of the adenoma from its surgical capsule, but performed entirely by perurethral endoscopic technique assisted by Holmium Laser. Materials and Methods: From March 2001 to November 2004, 219 patients under went HoLEP. After the initial cuts from bladder neck to verumontanum at 5 and 7 o′clock position, capsule is identified. The beak of the resectoscope sheath was inserted in the plane between the capsule and the adenoma and the adenoma was physically pushed away towards the urethra from the capsule. Laser was used to coagulate the bleeders, to cut the mucosal attachments and tough stromal tissue. Procedure was repeated for median and two lateral lobes. There was minimal bleeding and fluid absorption. Complications were few. Results: In 206 cases successful enucleation of the adenoma was carried out. First 13 cases formed part of the learning curve and were completed by standard transurethral resection of prostate (TURP. IPSS score dropped from average of 23 to 8 and peak flow improved from 20. No patient had postoperative urinary incontinence or stricture. Conclusions: HoLEP is an effective alternative to TURP. Ultimate end results replicate the end results of open enucleation of BPH without its morbidity and have all the advantages of endoscopic surgery. It offers distinct advantages over standard TURP as the incidence of blood transfusion and fluid absorption are greatly minimized.

  19. Magneto-optical study of holmium iron garnet Ho3Fe5O12

    Science.gov (United States)

    Kalashnikova, A. M.; Pavlov, V. V.; Kimel, A. V.; Kirilyuk, A.; Rasing, Th.; Pisarev, R. V.

    2012-09-01

    Bulk holmium iron garnet Ho3Fe5O12 is a cubic ferrimagnet with Curie temperature TC = 567 K and magnetization compensation point in the range 130-140 K. The magneto-optical data are presented for a holmium iron garnet Ho3Fe5O12 film, ˜10 μm thick, epitaxially grown on a (111)-type gadolinium-gallium garnet Gd3Ga5O12 substrate. A specific feature of this structure is that the parameters of the bulk material, from which the film was grown, closely match the substrate ones. The temperature and field dependences of Faraday rotation as well as the temperature dependence of the domain structure in zero field were investigated. The compensation point of the structure was found to be Tcomp = 127 K. It was shown that the temperature dependence of the characteristic size of domain structure diverges at this point. Based on the obtained results we established that the magnetic anisotropy of the material is determined by both uniaxial and cubic contributions, each characterized by different temperature dependence. A complex shape of hysteresis loops and sharp changes of the domain pattern with temperature indicate the presence of collinear-noncollinear phase transitions. Study of the optical second harmonic generation was carried out using 100 fs laser pulses with central photon energy E = 1.55 eV. The electric dipole contribution (both crystallographic and magnetic) to the second harmonic generation was observed with high reliability despite a small mismatch of the film and substrate parameters.

  20. A simple device to protect against osteoradionecrosis induced by interstitial irradiation

    International Nuclear Information System (INIS)

    Levendag, P.C.; Visch, L.L.; Driver, N.

    1990-01-01

    The incidence of osteoradionecrosis has declined since the introduction of preventive oral hygiene programs and meticulous dental evaluations before and after irradiation. Nevertheless, radiation dose per se still remains an important factor in osteoradionecrosis. Interstitial radiation has received much attention in the past decade since the use of flexible afterloading systems. It has become common practice in large oncology centers to implant radiation carriers in bulky tumor in the oral cavity and/or oropharynx. For interstitial radiation, with or without external radiation, minimal tumor doses are often cited to be more than 70 Gy. Unfortunately, if the mandible receives more than 70 Gy, it is at risk for the development of osteoradionecrosis. Therefore a simple protective lead device has been designed for routine use in brachytherapy in oral cavity tumors to reduce the dose to the mandible. This device will diminish the potential risk of osteoradionecrosis development

  1. Effects of ion beam irradiation on semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Nashiyama, Isamu; Hirao, Toshio; Itoh, Hisayoshi; Ohshima, Takeshi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    Energetic heavy-ion irradiation apparatus has been developed for single-event effects (SEE) testing. We have applied three irradiation methods such as a scattered-ion irradiation method, a recoiled-atom irradiation method, and a direct-beam irradiation method to perform SEE testing efficiently. (author)

  2. 29 CFR 1952.166 - Where the plan may be inspected.

    Science.gov (United States)

    2010-07-01

    ... copied during normal business hours at the following locations: Office of State Programs, Occupational... 29 Labor 9 2010-07-01 2010-07-01 false Where the plan may be inspected. 1952.166 Section 1952.166..., DEPARTMENT OF LABOR (CONTINUED) APPROVED STATE PLANS FOR ENFORCEMENT OF STATE STANDARDS Iowa § 1952.166 Where...

  3. 7 CFR 457.166 - Blueberry crop insurance provisions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Blueberry crop insurance provisions. 457.166 Section... CORPORATION, DEPARTMENT OF AGRICULTURE COMMON CROP INSURANCE REGULATIONS § 457.166 Blueberry crop insurance provisions. The Blueberry Crop Insurance Provisions for the 2005 and succeeding crop years are as follows...

  4. Wideband thulium–holmium-doped fiber source with combined forward and backward amplified spontaneous emission at 1600–2300 nm spectral band

    Czech Academy of Sciences Publication Activity Database

    Honzátko, Pavel; Baravets, Yauhen; Kašík, Ivan; Podrazký, Ondřej

    2014-01-01

    Roč. 39, č. 12 (2014), s. 3650-3653 ISSN 0146-9592 R&D Projects: GA ČR(CZ) GAP205/11/1840 Institutional support: RVO:67985882 Keywords : Bandwidth * Spontaneous emission * Holmium Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.292, year: 2014

  5. Magnetoresistance in terbium and holmium single crystals

    International Nuclear Information System (INIS)

    Singh, R.L.; Jericho, M.H.; Geldart, D.J.W.

    1976-01-01

    The longitudinal magnetoresistance of single crystals of terbium and holmium metals in their low-temperature ferromagnetic phase has been investigated in magnetic fields up to 80 kOe. Typical magnetoresistance isotherms exhibit a minimum which increases in depth and moves to higher fields as the temperature increases. The magnetoresistance around 1 0 K, where inelastic scattering is negligible, has been interpreted as the sum of a negative contribution due to changes in the domain structure and a positive contribution due to normal magnetoresistance. At higher temperatures, a phenomenological approach has been developed to extract the inelastic phonon and spin-wave components from the total measured magnetoresistance. In the temperature range 4--20 0 K (approximately), the phonon resistivity varies as T 3 . 7 for all samples. Approximate upper and lower bounds have been placed on the spin-wave resistivity which is also found to be described by a simple power law in this temperature range. The implications of this result for theoretical treatments of spin-wave resistivity due to s-f exchange interactions are considered. It is concluded that the role played by the magnon energy gap is far less transparent than previously suggested

  6. Gemstone enhancing dedicated gamma irradiator development

    International Nuclear Information System (INIS)

    Omi, Nelson Minoru

    2006-01-01

    The gemstones gamma irradiation process to enhance the color is widely accepted for the jewelry industry. These gems are processed in conventional industrial gamma irradiation plant which are optimized for other purposes, using underwater irradiation devices with high rejection rate due to it's poor dose uniformity. A new conception design, which states the working principles and manufacturing ways of the device, was developed in this work. The suggested device's design is based on the rotation of cylindrical baskets and their translation in circular paths inside and outside a cylindrical source rack as a planetary system. The device is meant to perform the irradiation in the bottom of the source storage pool, where the sources remain always shielded by the water layer. The irradiator matches the Category III IAEA classification. To verify the physical viability of the basic principle, tests with rotating cylindrical baskets were performed in the Multipurpose Irradiator raised in the CTR, IPEN. Also, simulations using the CADGAMMA software, adapted to simulate underwater irradiations were performed. With the definitive irradiator, the irradiation quality will be enhanced with better dose control and the production costs will be significantly lower than market prices due to the intended treatment device's optimization. (author)

  7. Separation of holmium (III) from aqueous chloride medium by Amberlite IRC748

    International Nuclear Information System (INIS)

    Vijayalakshmi, R.; Anitha, M.; Singh, D.K.; Chakravartty, J.K.

    2016-01-01

    High purity holmium finds applications in nuclear reactors as control rod, rare earth based magnetic alloys, lasers, medical applications, etc. Holmium belongs to the heavier group of rare earths and its content is very less (<0.5%) in Monazite mineral, hence its recovery from various potential sources becomes essential. Ion exchange technique is a well known method for effective separation, purification, recovery, and concentration of metal ions from lean aqueous solutions. It has also been widely used for separation and purification of rare earths. In the present investigation application of Amberlite IRC748, a chelating type of resin containing iminodiacetic acid functional group for separation of Ho(III) was explored. The effects of various parameters such as pH, contact time, weight of resin, initial metal concentration and temperature on the adsorption characteristics of Ho(III) were investigated in detail. The loading of Ho(III) ion onto resin increased with increasing the initial concentration. The adsorption was strongly dependent on pH of the medium with enhanced adsorption as the pH turned from 1 to 4. In the batch system, the Amberlite IRC748 resin exhibited the highest Ho(III) ion uptake as 180 mg/g at 298 K, at an initial pH value of 4. The adsorption data gave good fit with Langmuir isotherm which was better than the Freundlich curve. The thermodynamic parameters such as ΔH, ΔS and ΔG were evaluated from the temperature variation data. Negative value of ΔH (-11.5 kJ/mole), indicated that the adsorption of Ho(III) ion onto Amberlite resin was exothermic in nature. ΔS was found to be 5.52 J/mole/K. Kinetic study indicated that the adsorption data fitted the pseudo second order kinetic equation. (author)

  8. 40 CFR 166.45 - Duration of crisis exemption.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Duration of crisis exemption. 166.45... EXEMPTION OF FEDERAL AND STATE AGENCIES FOR USE OF PESTICIDES UNDER EMERGENCY CONDITIONS Crisis Exemptions § 166.45 Duration of crisis exemption. A crisis exemption may be authorized for: (a) Only as long as is...

  9. 40 CFR 166.50 - Reporting and recordkeeping requirements for crisis exemption.

    Science.gov (United States)

    2010-07-01

    ... requirements for crisis exemption. 166.50 Section 166.50 Protection of Environment ENVIRONMENTAL PROTECTION... EMERGENCY CONDITIONS Crisis Exemptions § 166.50 Reporting and recordkeeping requirements for crisis... a crisis exemption must be immediately reported to the Agency. (b) Final reports. (1) A report...

  10. Production of medical radioisotopes in the ORNL High Flux Isotope Reactor (HFIR) for cancer treatment and arterial restenosis therapy after PTCA

    International Nuclear Information System (INIS)

    Knapp, F.F. Jr.; Beets, A.L.; Mirzadeh, S.; Alexander, C.W.; Hobbs, R.L.

    1998-01-01

    The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL) represents an important resource for the production of a wide variety of medical radioisotopes. In addition to serving as a key production site for californium-252 and other transuranic elements, important examples of therapeutic radioisotopes which are currently routinely produced in the HFIR for distribution include dysprosium-166 (parent of holmium-166), rhenium-186, tin-117m and tungsten-188 (parent of rhenium-188). The nine hydraulic tube (HT) positions in the central high flux region permit the insertion and removal of targets at any time during the operating cycle and have traditionally represented a major site for production of medical radioisotopes. To increase the irradiation capabilities of the HFIR, special target holders have recently been designed and fabricated which will be installed in the six Peripheral Target Positions (PTP), which are also located in the high flux region. These positions are only accessible during reactor refueling and will be used for long-term irradiations, such as required for the production of tin-117m and tungsten-188. Each of the PTP tubes will be capable of housing a maximum of eight HT targets, thus increasing the total maximum number of HT targets from the current nine, to a total of 57. In this paper the therapeutic use of reactor-produced radioisotopes for bone pain palliation and vascular brachytherapy and the therapeutic medical radioisotope production capabilities of the ORNL HFIR are briefly discussed

  11. Anti-invasive and antiangiogenic effects of MMI-166 on malignant glioma cells

    International Nuclear Information System (INIS)

    Nakabayashi, Hiromichi; Yawata, Toshio; Shimizu, Keiji

    2010-01-01

    The constitutive overexpression of matrix metalloproteinases (MMPs) is frequently observed in malignant tumours. In particular, MMP-2 and MMP-9 have been reported to be closely associated with invasion and angiogenesis in malignant gliomas. Our study aimed to evaluate the antitumour effects of MMI-166 (Nalpha-[4-(2-Phenyl-2H- tetrazole-5-yl) phenyl sulfonyl]-D-tryptophan), a third generation MMP inhibitor, on three human glioma cell lines (T98G, U87MG, and ONS12) in vitro and in vivo. The effects of MMI-166 on the gelatinolytic activity was analysed by gelatine zymography. The anti-invasive effect of MMI-166 was analysed by an in vitro invasion assay. An in vitro angiogenesis assay was also performed. In vitro growth inhibition of glioma cells by MMI-166 was determined by the MTT assay. The effect of MMI-166 on an orthotropic implantation model using athymic mice was also evaluated. Gelatine zymography revealed that MMP-2 and MMP-9 activities were suppressed by MMI-166. The invasion of glioma cells was suppressed by MMI-166. The angiogenesis assay showed that MMI-166 had a suppressive effect on glioma cell-induced angiogenesis. However, MMI-166 did not suppress glioma cell proliferation in the MTT assay. In vivo, MMI-166 suppressed tumour growth in athymic mice implanted orthotropically with T98G cells and showed an inhibitory effect on tumour-induced angiogenesis and tumour growth. This is the first report of the effect of a third generation MMP inhibitor on malignant glioma cells. These results suggest that MMI-166 may have potentially suppressive effects on the invasion and angiogenesis of malignant gliomas

  12. 经皮肾穿刺钬激光碎石术后疼痛的护理干预%Nursing intervention of postoperative pain after percutaneous nephrolithotomy holmium laser

    Institute of Scientific and Technical Information of China (English)

    白玫; 乔够梅; 杏玲芝; 陆皓

    2012-01-01

    目的:探讨护理干预对减轻经皮肾穿刺钬激光碎石术后疼痛的效果.方法:随机将264例经皮肾穿刺钬激光碎石术患者分成干预组和对照组各132例.对照组患者给予经皮肾穿刺钬激光碎石术后常规护理,干预组在对照组的基础上进行一系列的护理干预.结果:干预组术后疼痛明显低于对照组(P<0.05).结论:护理干预在经皮肾穿刺钬激光碎石术后应用能明显减轻患者疼痛,加速患者术后康复,有利于护理质量的提高.%Objective:To study the nursing intervention on reducing percutaneous holmium laser effect of postoperative pain. Methods:264 patients randomized to percutaneous nephrolithotomy with holmium laser lithotripsy were divided into intervention group and control group of 132 cases at radom. The control group conventional percutaneous holmium laser lithotripsy postoperative care, intervention group were based on a series of nursing intervention. Results postoperative pain of intervention group was significantly lower than control group ( P <0.05 ). Conclusion: Nursing intervention in percutaneous holmium laser lithotripsy in patients with significantly reduced postoperative pain,accelerated postoperative recovery, is conducive to improving quality of care.

  13. Re-irradiation for abdominal tumor. Preliminary results

    International Nuclear Information System (INIS)

    Narisada, Hiroyuki; Imada, Hajime; Tomoda, Yoshinori

    2012-01-01

    The purpose of this study was to assess the efficacy of loco-regional radiotherapy for recurrent abdominal tumor treated with re-irradiation. Re-irradiated areas of 16 patients were eight of pelvic space, five of retroperitonium and three of liver or porta hepatica. Eligibility criteria of re-irradiation were success of initial irradiation, no other effective treatment except re-irradiation, constancy of bowel gas at hunger status and respiratory movement, visceral dosage reduction at re-irradiation. Total dose of initial, second course of radiation were 51.3±10.8 Gy, 50.6±14.2 Gy, respectively. Interval of initial and second course of radiation were 16.6±10.2 months. Local control after second course of radiation was four cases of complete response, five of partial response and seven of stable disease. Median survival periods were 55 months after initial treatment and 28 months after second course of radiation. In two cases of pelvic reirradiation, skin to pelvic space fistula was occurred. Re-irradiation for abdominal tumor may become useful salvage treatment. (author)

  14. Holmium Laser Enucleation of the Prostate and Iatrogenic Arteriovenous Fistula Treated by Superselective Arterial Embolization

    Directory of Open Access Journals (Sweden)

    Anastasios D. Asimakopoulos

    2016-01-01

    Full Text Available Iatrogenic pelvic pseudoaneurysm with concomitant arteriovenous fistula has been described as a rare and challenging complication, which may occur during transurethral resection of the prostate. We provide the first report of this complication after holmium laser enucleation of the prostate for the treatment of benign prostatic hyperplasia. The attempt to control the bleeding by conversion to open surgery and placement of haemostatic stitches into the prostatic fossa failed. Angiography with superselective arterial embolization proved to be a modern, quick, safe, and efficient treatment of this uncommon complication.

  15. Behavior of a thermoelectric power generation device based on solar irradiation and the earth’s surface-air temperature difference

    International Nuclear Information System (INIS)

    Zhang, Zhe; Li, Wenbin; Kan, Jiangming

    2015-01-01

    Highlights: • A technical solution to the power supply of wireless sensor networks is presented. • The low voltage produced by TEG is boosted from less than 1 V to more than 4 V. • An output current and voltage of TEG device is acquired as 21.47 mA and 221 mV. • The device successfully provides output power 4.7 mW in no electricity conditions. • The thermo-economic value of TEG device is demonstrated. - Abstract: Motivated by the limited power supply of wireless sensors used to monitor the natural environment, for example, in forests, this study presents a technical solution by recycling solar irradiation heat using thermoelectric generators. Based on solar irradiation and the earth’s surface-air temperature difference, a new type of thermoelectric power generation device has been devised, the distinguishing features of which include the application of an all-glass heat-tube-type vacuum solar heat collection pipe to absorb and transfer solar energy without a water medium and the use of a thin heat dissipation tube to cool the earth surface air temperature. The effects of key parameters such as solar illumination, air temperature, load resistance, the proportional coefficient, output power and power generation efficiency for thermoelectric energy conversion are analyzed. The results of realistic outdoor experiments show that under a state of regular illumination at 3.75 × 10 4 lx, using one TEG module, the thermoelectric device is able to boost the voltage obtained from the natural solar irradiation from 221 mV to 4.41 V, with an output power of 4.7 mW. This means that the electrical energy generated can provide the power supply for low power consumption components, such as low power wireless sensors, ZigBee modules and other low power loads

  16. Improvement of the center boring device for the irradiated fuel pellets

    Energy Technology Data Exchange (ETDEWEB)

    Usami, Koji; Onozawa, Atsushi; Kimura, Yasuhiko; Sakuraba, Naotoshi; Shiina, Hidenori; Harada, Akito; Nakata, Masahito [Japan Atomic Energy Agency, Nuclear Science Research Inst., Tokai, Ibaraki (Japan)

    2012-03-15

    The power ramp tests performed at JMTR in Oarai R and D Center are objected to study the safety margin of the high burnup fuels. One of the important parameters measured during this test is the center temperature of the fuel pellet. For this measurement, a thermocouple is installed into the hole bored at the pellet center by the center boring device, which can fix the fuel pellet with the frozen CO{sub 2} gas during its boring process. At the Reactor Fuel Examination Facility (RFEF) in Tokai R and D Center, several improvements were applied for the previous boring device to gain its performance and reliability. The major improvements are the change of the drill bit, modification of the boring process and the optimization of the remote operability. The mock-up test will be performed with the irradiated fuel pellet to confirm the benefit of improvement. This study was conducted under a contract with the Nuclear and Industrial Safety Agency (NISA) of the Ministry of Economy, Trade and Industry (METI). (author)

  17. 9 CFR 166.8 - Vehicles used to transport garbage.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Vehicles used to transport garbage. 166.8 Section 166.8 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT... used to transport garbage. Vehicles used by a licensee to transport untreated garbage, except those...

  18. Effects of 6 MeV electron irradiation on the electrical properties and device parameters of Al/Al2O3/TiO2/n-Si MOS capacitors

    International Nuclear Information System (INIS)

    Laha, P.; Banerjee, I.; Barhai, P.K.; Das, A.K.; Bhoraskar, V.N.; Mahapatra, S.K.

    2012-01-01

    Highlights: ► The electron irradiation effects make variation in the device parameters. ► The device parameters changes due to percentage of defects and charge trapping. ► Leakage current of Al/Al 2 O 3 /TiO 2 /n-Si changes due to interface dangling bonds. ► The leakage current mechanism of MOS structures is due to Poole–Frenkel effect. - Abstract: The effects of 6 MeV electron irradiation on the electrical properties and device parameter characteristics of Al/Al 2 O 3 /TiO 2 /n-Si metal–oxide–semiconductor capacitors have been studied. Twelve Al/Al 2 O 3 /TiO 2 /n-Si MOS capacitors were fabricated using r.f. magnetron sputtering and divided into four groups. The first group was not irradiated and treated as virgin. The rest were irradiated with 6 MeV electrons at doses 10, 20, and 30 kGy, maintaining the dose rate at ∼1 kGy/min. Variations in crystallinity of the virgin and irradiated capacitors were studied using grazing incident X-ray diffraction. The thickness and in-depth elemental distributions of individual layers were determined using secondary ion mass apectrometry. Capacitance–voltage, conductance–voltage and leakage current–voltage characteristics of the virgin and irradiated samples were studied. The device parameters (flat band voltage, surface charge density and interface trap density of the virgin and irradiated structures) were determined. The electrical properties of the capacitors were investigated and the Poole–Frenkel coefficient of the capacitors was determined from leakage current measurements. The leakage current mechanism has been explained.

  19. Animal experiments and clinical trials of 166Ho-Chitosan for various cancers

    International Nuclear Information System (INIS)

    Lim, S.M.; Choi, C.W.; Park, S.Y.; Lee, S.H.; Lee, B.H.; Park, K.B.

    1998-01-01

    166 Ho-Chitosan is a complex of 166 Ho and N-glucosamine with 400 to 500 kD MW, which chelates metal ions and degrades slowly in vivo. In mice, 166 H-Chitosan administered intraperitoneally was uniformly bound to the peritoneal wall (94%), and the surface dose calculated by Monte Carlo simulation (EGS 4 code) was 81 Gy/uCi/cm 2 . 166 Ho-Chitosan was administered intraperitoneally as an adjunct in the treatment of ovarian cancer with diffuse spread of malignant cells in the peritoneal surfaces including the diaphragm. 97-99% of 166 Ho-Chitosan was localized within the peritoneal cavity, and more than 90% of 166 Ho-Chitosan was attached to the peritoneal wall. Partial response were observed in 4 among 5 patients with ovarian cancer without severe toxicity. Intracavitary radiation therapy with 166 Ho-Chitosan in the cystic brain tumor, 5 or 8 cysts were shrunken in size with thinning of the wall, 2 out of 8 showed growth retardation. For large or multiple primary liver cancers, which were inoperable and resistent to chemotherapy. 166 Ho-Chitosan was used for intraarterial injection, because this solution became gel with neutral pH. In the primary liver cancer, radioactivity was distributed in the territory of selected hepatic arterial branch, and partial responses were observed in 2 cases. For the large solitary liver tumor, which was not operable due to its location, direct intratumoral injection of the radioisotope had a limited response. 18 FDG PET was a useful tool to follow up those radionuclide therapy, and guide to plan the next therapy. In one case of the large single metastatic stomach cancer in the liver, 18 FDG PET was done two weeks after intratumoral injection of 166 Ho-Chitosan, which showed cold defects matched with distribution of 166 Ho-Chitosan, and second injection was guided by PET image. Various methods of the administration of 166 Ho-Chitosan could be used for the treatment of the cancers. (author)

  20. Lande gJ factors for even-parity electronic levels in the holmium atom

    Science.gov (United States)

    Stefanska, D.; Werbowy, S.; Krzykowski, A.; Furmann, B.

    2018-05-01

    In this work the hyperfine structure of the Zeeman splitting for 18 even-parity levels in the holmium atom was investigated. The experimental method applied was laser induced fluorescence in a hollow cathode discharge lamp. 20 spectral lines were investigated involving odd-parity levels from the ground multiplet, for which Lande gJ factors are known with high precision, as the lower levels; this greatly facilitated the evaluation of gJ factors for the upper levels. The gJ values for the even-parity levels considered are reported for the first time. They proved to compare fairly well with the values obtained recently in a semi-empirical analysis for the even-parity level system of Ho I.

  1. Preliminary decay heat calculations for the fuel loaded irradiation loop device of the RMB multipurpose Brazilian reactor

    Energy Technology Data Exchange (ETDEWEB)

    Campolina, Daniel; Costa, Antonio Carlos L. da; Andrade, Edison P., E-mail: campolina@cdtn.br, E-mail: aclp@cdtn.br, E-mail: epa@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (SETRE/CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Servico de Tecnologia de Reatores

    2017-07-01

    The structuring project of the Brazilian Multipurpose Reactor (RMB) is responsible for meeting the capacity to develop and test materials and nuclear fuel for the Brazilian Nuclear Program. An irradiation test device (Loop) capable of performing fuel test for power reactor rods is being conceived for RMB reflector. In this work preliminary neutronic calculations have been carried out in order to determine parameters to the cooling system of the Loop basic design. The heat released as a result of radioactive decay of fuel samples was calculated using ORIGEN-ARP and it resulted less than 200 W after 1 hour of irradiation interruption. (author)

  2. Phylogenetic analysis reveals conservation and diversification of micro RNA166 genes among diverse plant species.

    Science.gov (United States)

    Barik, Suvakanta; SarkarDas, Shabari; Singh, Archita; Gautam, Vibhav; Kumar, Pramod; Majee, Manoj; Sarkar, Ananda K

    2014-01-01

    Similar to the majority of the microRNAs, mature miR166s are derived from multiple members of MIR166 genes (precursors) and regulate various aspects of plant development by negatively regulating their target genes (Class III HD-ZIP). The evolutionary conservation or functional diversification of miRNA166 family members remains elusive. Here, we show the phylogenetic relationships among MIR166 precursor and mature sequences from three diverse model plant species. Despite strong conservation, some mature miR166 sequences, such as ppt-miR166m, have undergone sequence variation. Critical sequence variation in ppt-miR166m has led to functional diversification, as it targets non-HD-ZIPIII gene transcript (s). MIR166 precursor sequences have diverged in a lineage specific manner, and both precursors and mature osa-miR166i/j are highly conserved. Interestingly, polycistronic MIR166s were present in Physcomitrella and Oryza but not in Arabidopsis. The nature of cis-regulatory motifs on the upstream promoter sequences of MIR166 genes indicates their possible contribution to the functional variation observed among miR166 species. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Synthesis, Characterization and Thermal Diffusivity of Holmium and Praseodymium Zirconates

    Directory of Open Access Journals (Sweden)

    Stopyra M.

    2016-06-01

    Full Text Available A2B2O7 oxides with pyrochlore or defected fluorite structure are among the most promising candidates for insulation layer material in thermal barrier coatings. The present paper presents the procedure of synthesis of holmium zirconate Ho2Zr2O7 and praseodymium zirconate Pr2Zr2O7 via Polymerized-Complex Method (PCM. Thermal analysis of precursor revealed that after calcination at relatively low temperature (700°C fine-crystalline, single-phase material is obtained. Thermal diffusivity was measured in temperature range 25-200°C, Ho2Zr2O7 exhibits lower thermal diffusivity than Pr2Zr2O7. Additionally, PrHoZr2O7 was synthesized. The powder in as-calcined condition is single-phase, but during the sintering decomposition of solid solution took place and Ho-rich phase precipitated. This material exhibited the best insulating properties among the tested ones.

  4. Irradiation creep at temperatures of 400 degrees C and below for application to near-term fusion devices

    International Nuclear Information System (INIS)

    Grossbeck, M.L.; Gibson, L.T.; Mansur, L.K.

    1996-01-01

    To study irradiation creep at 400 degrees C and below, a series of six austenitic stainless steels and two ferritic alloys was irradiated sequentially in two research reactors where the neutron spectrum was tailored to produce a He production rate typical of a fusion device. Irradiation began in the Oak Ridge Research Reactor; and, after an atomic displacement level of 7.4 dpa, the specimens were moved to the High Flux Isotope Reactor for the remainder of the 19 dpa accumulated. Irradiation temperatures of 60, 200, 330, and 400 degrees C were studied with internally pressurized tubes of type 316 stainless steel, PCA, HT 9, and a series of four laboratory heats of: Fe-13.5Cr-15Ni, Fe-13.5Cr-35Ni, Fe-1 3.5Cr-1 W-0.18Ti, and Fe-16Cr. At 330 degrees C, irradiation creep was shown to be linear in fluence and stress. There was little or no effect of cold-work on creep under these conditions at all temperatures investigated. The HT9 demonstrated a large deviation from linearity at high stress levels, and a minimum in irradiation creep with increasing stress was observed in the Fe-Cr-Ni ternary alloys

  5. 31 CFR 16.6 - Prerequisites for issuing a complaint.

    Science.gov (United States)

    2010-07-01

    .... 16.6 Section 16.6 Money and Finance: Treasury Office of the Secretary of the Treasury REGULATIONS... defined in paragraph (b) of this section), the amount of money or the value of property or services demanded or requested in violation of § 16.3(a) does not exceed $150,000. (b) For the purposes of this...

  6. Synthesis and optical properties of antimony oxide glasses doped with holmium trioxide

    Energy Technology Data Exchange (ETDEWEB)

    Raghunatha, S.; Eraiah, B., E-mail: eraiah@rediffmail.com [Department of physics, Bangalore University, Bengaluru – 560 056. India (India)

    2016-05-06

    Holmium doped lithium-antimony-lead borate glasses having 1 mol% AgNO{sub 3} with composition 50B{sub 2}O{sub 3}-20PbO-25Sb{sub 2}O{sub 3}-5Li{sub 2}O have been prepared using single step melt quenching technique. The XRD spectrum confirms amorphous nature of glasses. The optical absorbance studies were carried out on these glasses. The optical direct band gap energies were found to be in the range of 3.10 eV to 3.31 eV and indirect band gap energies were found to be in the range of 2.28 eV to 3.00 eV. The refractive indexes have been calculated by using Lorentz-Lorenz formula and the calculated values in the range of 2.31 to 2.37.

  7. New trends in nuclear fuel experimental irradiation. Modern control and acquisition of the irradiation data

    International Nuclear Information System (INIS)

    Preda, M.; Ciocanescu, M.; Ana, E.M.

    2010-01-01

    With the irradiation devices used in the irradiation tests, the following experiments have been performed in TRIGA-SCN reactor: a) In capsule-type irradiation devices: - fission gases composition determination; - dimensional measurements; - fission gases pressure measurement; - power pre-ramp and ramp; - power cycling; - structural materials testing. b) In loop-type irradiation device: - power ramp; - multiple power ramps; - overpower. Aiming to develop irradiation tests for advanced nuclear fuel elements, it is mandatory to increase the maximum neutron flux in the core with about 20%. This will lead to reactor power increase up to 21 MW. This objective can be reached through: - increasing the number of fuel clusters in the reactor core; - using the 6x6 fuel cluster to replace the present 5x5 clusters; - relocation of the control rods. In this context, the new control system and the data acquisition system operates online and allows real-time data evaluation. (author)

  8. Low-power holmium:YAG laser urethrotomy for treatment of urethral strictures: functional outcome and quality of life.

    Science.gov (United States)

    Kamp, Stefan; Knoll, Thomas; Osman, Mahmoud M; Köhrmann, Kai Uwe; Michel, Maurice S; Alken, Peter

    2006-01-01

    To evaluate the efficacy of endourethrotomy with the holmium:YAG laser as a minimally invasive treatment for urethral stricture. Between January 2002 and January 2004, 32 male patients with symptomatic urethral strictures (8 bulbar, 9 penile, 9 combined) were treated with Ho:YAG-laser urethrotomy in our department. The stricture was iatrogenic in 60% (N = 18), inflammatory in 16.6% (N = 5), traumatic in 13.3% (N = 4), and idiopathic in 7% (N = 3). The stricture was incised under vision at the 12 o'clock location or the site of maximum scar tissue or narrowing in asymmetric strictures. Laser energy was set on 1200 to 1400 mJ with a frequency of 10 to 13 Hz. Postoperatively, drainage of the bladder was performed for 4 days using a 18F silicone catheter. Triamcinolone was instilled intraurethrally after removal of the catheter in all patients. Patients were followed up by mailed questionnaire, including International Prostate Symptom Score and quality of life. Retrograde endoscopic Ho:YAG laser urethrotomy could be performed in all 32 patients. Most patients (22; 68.7%) did not need any reintervention. Ten patients developed recurrent strictures that were treated by another laser urethrotomy in 4 patients (12.5%), while 6 patients (18.7%) needed open urethroplasty with buccal mucosa. Including 2 patients treated with repeat laser urethrotomy, 24 patients (75%) were considered successful after a mean follow-up of 27 months (range 13-38 months). No intraoperative complications were encountered, although in 5% of patients, a urinary-tract infection was diagnosed postoperatively. No gross hematuria occurred. The Ho:YAG laser urethrotomy is a safe and effective minimally invasive therapeutic modality for urethral stricture with results comparable to those of conventional urethrotomy. Further data from long-time follow-up are necessary to compare the success rate with that of conventional urethrotomy and urethroplasty. Nevertheless, the Ho:YAG laser urethrotomy might at

  9. 25 CFR 166.1000 - Who owns the records associated with this part?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Who owns the records associated with this part? 166.1000 Section 166.1000 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER GRAZING PERMITS Records § 166.1000 Who owns the records associated with this part? (a) Records are the property of...

  10. DXD Motif-Dependent and -Independent Effects of the Chlamydia trachomatis Cytotoxin CT166

    Directory of Open Access Journals (Sweden)

    Miriam Bothe

    2015-02-01

    Full Text Available The Gram-negative, intracellular bacterium Chlamydia trachomatis causes acute and chronic urogenital tract infection, potentially leading to infertility and ectopic pregnancy. The only partially characterized cytotoxin CT166 of serovar D exhibits a DXD motif, which is important for the enzymatic activity of many bacterial and mammalian type A glycosyltransferases, leading to the hypothesis that CT166 possess glycosyltransferase activity. CT166-expressing HeLa cells exhibit actin reorganization, including cell rounding, which has been attributed to the inhibition of the Rho-GTPases Rac/Cdc42. Exploiting the glycosylation-sensitive Ras(27H5 antibody, we here show that CT166 induces an epitope change in Ras, resulting in inhibited ERK and PI3K signaling and delayed cell cycle progression. Consistent with the hypothesis that these effects strictly depend on the DXD motif, CT166 with the mutated DXD motif causes neither Ras-ERK inhibition nor delayed cell cycle progression. In contrast, CT166 with the mutated DXD motif is still capable of inhibiting cell migration, suggesting that CT166 with the mutated DXD motif cannot be regarded as inactive in any case. Taken together, CT166 affects various fundamental cellular processes, strongly suggesting its importance for the intracellular survival of chlamydia.

  11. Development of phosphate glass microspheres containing holmium for selective internal radiotherapy

    International Nuclear Information System (INIS)

    Barros Filho, Eraldo Cordeiro

    2016-01-01

    The selective internal radiotherapy is an alternative for some kinds of cancer as the hepatocellular carcinoma (HCC) or primary liver cancer treatment. In this treatment, glass or polymer microspheres containing radionuclides inside their structure are introduced in the liver through hepatic artery and trapped at the arterioles that feed the tumor. In this work, the development of phosphate glasses containing holmium for production of microspheres and their application in Brazil are proposed. The developed glasses presented suitable chemical durability, density of 2,7(3) g/cm 3 , high thermal stability and the impurities contained therein do not preclude the treatment. The microspheres were produced by the flame method and the gravitational fall method, and were characterized by means of several techniques to evaluate shape, average particle size, activity and biocompatibility suitable for selective internal radiotherapy. Based in the main results, the submission to in vivo tests is proposed. (author)

  12. Evaluation of erbium:YAG and holmium:YAG laser radiation and dental hard tissue

    Science.gov (United States)

    Attrill, David Cameron

    and evidence of molten enamel in particular were apparent when the Er:YAG laser was used without water. The Cr-Tm-Ho;YAG laser produced extensive charring and carbonisation of tissues. It was concluded that this laser was unsuitable for clinical applications directed at the removal or modification of enamel and dentine, particularly as the Er:YAG laser offers superior qualities. Further research with the Cr-Tm-Ho:YAG laser was discontinued. A comparison of the mean shear bond strengths of a composite (ZlOO, 3M Dental Products) bonded to enamel was made using either a conventional acid etch technique or one of a range of experimental Er:YAG laser etching configurations. The mean values for acid etching (16.6 MPa) were in all cases significantly greater (pcracking was noted in most laser etched surfaces, but the extent of this was minimised when the laser was applied in conjunction with a surface water film. Pulpal temperature increments following Er:YAG laser irradiation were significantly lower in teeth prepared with water than without (paired t-test, p<0.01). The largest increment in samples prepared with water was 3.9°C, compared to 24.7°C without water. The principal determinant of the temperature increment in either group was the total delivered energy, up to 140J. Linear regression modelling predicts that continuous irradiation up to 160J with water would not result in iatrogenic pulpal damage. In conclusion, the Er:YAG laser was shown to be an effective tool for cutting and modifying dental hard tissues. It almost certainly offers the best combination of safety, efficiency and speed of any laser system designed for preparing cavities. The laser must be used in conjunction with a water coolant on the tissues to minimise the possibility of iatrogenic damage, improve the quality of the laser cuts and in some circumstances increase cutting efficiency. The Er:YAG laser has shown much promise in these in vitro experiments and its progression to clinical use is

  13. 25 CFR 166.219 - How do I acquire a permit through negotiation?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false How do I acquire a permit through negotiation? 166.219 Section 166.219 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER GRAZING PERMITS Permit Requirements Obtaining A Permit § 166.219 How do I acquire a permit through negotiation? (a) Permits may be negotiated and granted by th...

  14. The IMO-1 mobile irradiation unit

    International Nuclear Information System (INIS)

    Cancio, Ruben; Gomez, Aristobulo; Mugliaroli, Hugo.

    1976-07-01

    The IMO-I is made up by a gamma irradiation bucket and a fixed source, mounted on a trailer specially designed. This equipment has been completed with a radiocomunication device. The irradiator unit consist of two fixed and one movable body. The irradiation bucket has a volume of 30 x 40 x 30 cm and is moved through an hydraulic system with allows its vertical movement between the upper or charging position and the bottom or irradiation position. The telecontrol device has been installed in the room contiguous to the irradiator. The conventional industrial sources of Co 60 , are vertically located in stainless steel source holders at the botton fixed body and they can be changed according with the desired geometry. The trailer has been built over a plain chassis assembled structure with a double axle at the rear. It consists of two rooms, one for the irradiator machine and the other one for the telecontrol device and the radiocomunication facility. (author) [es

  15. 40 CFR 166.20 - Application for a specific, quarantine, or public health exemption.

    Science.gov (United States)

    2010-07-01

    ..., or public health exemption. 166.20 Section 166.20 Protection of Environment ENVIRONMENTAL PROTECTION... EMERGENCY CONDITIONS Specific, Quarantine, and Public Health Exemptions § 166.20 Application for a specific, quarantine, or public health exemption. (a) General information required in an application for a specific...

  16. Optical and electrical doping of silicon with holmium

    International Nuclear Information System (INIS)

    Suyver, J.F.; Kik, P.G.; Kimura, T.; Polman, A.; Franzo, G.; Coffa, S.

    1999-01-01

    2 MeV holmium ions were implanted into Czochralski grown Si at a fluence of 5.5x10 14 Ho/cm 2 . Some samples were co-implanted with oxygen to a concentration of (7±1)x10 19 cm -3 . After recrystallization, strong Ho segregation to the surface is observed, which is fully suppressed by co-doping with O. After recrystallization, photoluminescence peaks are observed at 1.197, 1.96 and 2.06 μm, characteristic for the 5 I 6 → 5 I 8 and 5 I 7 → 5 I 8 transitions of Ho 3+ . The Ho 3+ luminescence lifetime at 1.197 μm is 14 ms at 12 K. The luminescence intensity shows temperature quenching with an activation energy of 11 meV, both with and without O co-doping. The observed PL quenching cannot be explained by free carrier Auger quenching, but instead must be due to energy backtransfer or electron hole pair dissociation. Spreading resistance measurements indicate that Ho exhibits donor behavior, and that in the presence of O the free carrier concentration is enhanced by more than two orders of magnitude. In the O co-doped sample 20% of the Ho 3+ was electrically active at room temperature

  17. Clitoral therapy device for treatment of sexual dysfunction in irradiated cervical cancer patients

    International Nuclear Information System (INIS)

    Schroder, MaryAnn; Mell, Loren K.; Hurteau, Jean A.; Collins, Yvonne C.; Rotmensch, Jacob; Waggoner, Steven E.; Yamada, S. Diane; Small, William; Mundt, Arno J.

    2005-01-01

    Purpose: The purpose of this pilot study was to evaluate the efficacy of the clitoral therapy device (Eros Therapy) in alleviating sexual dysfunction in irradiated cervical cancer patients. Methods and materials: Eligible patients had a history of cervical cancer treated with radiotherapy and self-reported sexual dysfunction of sexual arousal and/or orgasmic disorders. Patients used the noninvasive, nonpharmacologic clitoral therapy device using a hand-held, battery-powered vacuum to cause clitoral engorgement four times weekly for 3 months during foreplay and self-stimulation. Study instruments included the Female Sexual Function Index, Derogatis Interview for Sexual Functioning, and Dyadic Adjustment Scale. The outcome evaluation was performed at 3 months. Results: Between 2001 and 2002, 15 women were enrolled and 13 completed the study. The median patient age and radiotherapy-enrollment interval was 43.5 years and 2 years, respectively. At baseline, all patients reported symptoms of sexual arousal and/or orgasmic disorders, and some also had sexual desire and pain disorders. At 3 months, statistically significant improvements were seen in all domains tested, including sexual desire, arousal, lubrication, orgasm, sexual satisfaction, and reduced pain. The median Female Sexual Function Index total score increased from 17 to 29.4 (maximal score, 36; p <0.001). The median Derogatis Interview for Sexual Functioning total raw score increased from 46 to 95 (maximal score, 118; p <0.001). At baseline, the Derogatis Interview for Sexual Functioning total T-score corresponded to the bottom 10th percentile of normal sexual functioning. At 3 months, the total T-score placed the patients at the normalcy cutoff. Gynecologic examinations revealed improved mucosal color and moisture and vaginal elasticity and decreased bleeding and ulceration. Conclusion: Our results from this pilot study suggest that the clitoral therapy device may alleviate sexual dysfunction in irradiated

  18. Endoscopic removal of a proximal urethral stent using a holmium laser: Case report and literature review

    Directory of Open Access Journals (Sweden)

    Francisco Botelho

    2012-01-01

    Full Text Available Urethral stents were initially developed for the management of urethral strictures and obstructive voiding disorders in select patients. Urethral stent complications are common and may require stent explantation, which is often quite challenging. We present our experience with endoscopic removal of an encrusted UroLume proximal urethral stent in a 72-year-old male using a holmium laser. The literature on various management options and outcomes for urethral stent removal is reviewed. Endoscopic removal of proximal urethral stents is feasible and safe and should be considered as the primary treatment option in patients requiring stent extraction.

  19. 46 CFR 166.10 - Course of study for engineering students.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Course of study for engineering students. 166.10 Section... AND APPROVAL OF NAUTICAL SCHOOL SHIPS § 166.10 Course of study for engineering students. The course of study for engineering students shall include (a) all the instruction necessary to fully equip the...

  20. CD166/ALCAM expression is characteristic of tumorigenicity and invasive and migratory activities of pancreatic cancer cells.

    Directory of Open Access Journals (Sweden)

    Kenji Fujiwara

    Full Text Available CD166, also known as activated leukocyte cell adhesion molecule (ALCAM, is expressed by various cells in several tissues including cancer. However, the role of CD166 in malignant tumors is controversial, especially in pancreatic cancer. This study aimed to clarify the role and significance of CD166 expression in pancreatic cancer.We performed immunohistochemistry and flow cytometry to analyze the expression of CD166 in surgical pancreatic tissues and pancreatic cancer cell lines. The differences between isolated CD166+ and CD166- pancreatic cancer cells were analyzed by invasion and migration assays, and in mouse xenograft models. We also performed quantitative RT-PCR and microarray analyses to evaluate the expression levels of CD166 and related genes in cultured cells.Immunohistochemistry revealed high expression of CD166 in pancreatic cancer tissues (12.2%; 12/98 compared with that in normal pancreas controls (0%; 0/17 (p = 0.0435. Flow cytometry indicated that CD166 was expressed in 33.8-70.2% of cells in surgical pancreatic tissues and 0-99.5% of pancreatic cancer cell lines. Invasion and migration assays demonstrated that CD166- pancreatic cancer cells showed stronger invasive and migratory activities than those of CD166+ cancer cells (p<0.05. On the other hand, CD166+ Panc-1 cells showed a significantly stronger colony formation activity than that of CD166- Panc-1 cells (p<0.05. In vivo analysis revealed that CD166+ cells elicited significantly greater tumor growth than that of CD166- cells (p<0.05 in both subcutaneous and orthotopic mouse tumor models. mRNA expression of the epithelial-mesenchymal transition activator Zeb1 was over-expressed in CD166- cells (p<0.001. Microarray analysis showed that TSPAN8 and BST2 were over-expressed in CD166+ cells, while BMP7 and Col6A1 were over-expressed in CD166- cells.CD166+ pancreatic cancer cells are strongly tumorigenic, while CD166- pancreatic cancer cells exhibit comparatively stronger

  1. Neutronic and thermal-hydraulic analysis of a device for irradiation of LEU UAlx-Al targets for 99Mo production in the IEA-R1 reactor

    International Nuclear Information System (INIS)

    Nishiyama, Pedro Julio Batista de Oliveira

    2012-01-01

    Technetium-99m ( 99m Tc), the product of radioactive decay of molybdenum-99 ( Mo), is one of the most widely used radioisotope in nuclear medicine, covering approximately 80% of all radiodiagnosis procedures in the world. Nowadays, Brazil requires an amount of about 450 Ci of 99 Mo per week. Due to the crisis and the shortage of 99 Mo supply chain that has been observed on the world since 2008, IPEN/CNEN-SP decided to develop a project to produce 99 Mo through fission of uranium-235. The objective of this dissertation was the development of neutronic and thermal-hydraulic calculations to evaluate the operational safety of a device for 99 Mo production to be irradiated in the IEA-Rl reactor core at 5 MW. In this device will be placed ten targets of UAl x -Al dispersion fuel with low enriched uranium (LEU) and density of 2.889 gU/cm 3 . For the neutronic calculations were utilized the computer codes HAMMER-TECHNION and CITATION and the maximum temperatures reached in the targets were calculated with the code MTRCR-IEA-R1. The analysis demonstrated that the device irradiation will occur without adverse consequences to the operation of the reactor. The total amount of 99 Mo was calculated with the program SCALE and considering that the time needed for the chemical processing and recovering of the 99 Mo will be five days after the irradiation, we have that the 99 Mo activity available for distribution will be 176 Ci for 3 days of irradiation, 236 Ci for 5 days of irradiation and 272 Ci for 7 days of targets irradiation. (author)'

  2. Bouveret's syndrome complicated by distal gallstone ileus after laser lithotropsy using Holmium: YAG laser

    Directory of Open Access Journals (Sweden)

    Rodgers John B

    2002-06-01

    Full Text Available Abstract Background Bouveret's syndrome is an unusual presentation of duodenal obstruction caused by the passage of a large gallstone through a cholecystoduodenal fistula. Endoscopic therapy has been used as first-line treatment, especially in patients with high surgical risk. Case presentation We report a 67-year-old woman who underwent an endoscopic attempt to fragment and retrieve a duodenal stone using a Holmium: Yttrium-Aluminum-Garnet Laser (Ho:YAG which resulted in small bowel obstruction. The patient successfully underwent enterolithotomy without cholecystectomy or closure of the fistula. Conclusion We conclude that, distal gallstone obstruction, due to migration of partially fragmented stones, can occur as a possible complication of laser lithotripsy treatment of Bouveret's syndrome and might require urgent enterolithotomy.

  3. Neutronic, thermal-hydraulics and accident analysis calculations for an irradiation device to be used in the qualification process of dispersion fuels in the IEA-R1 research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Domingos, Douglas Borges; Silva, Antonio Teixeira e; Umbehaun, Pedro Ernesto; Silva, Jose Eduardo Rosa da; Conti, Thadeu das Neves; Yamaguchi, Mitsuo [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil)], e-mail: douglasborgesdomingos@yahoo.com.br

    2009-07-01

    Neutronic, thermal-hydraulics and accident analysis calculations were developed to estimate the safety of an irradiation device placed in the IEA-R1 reactor core. The irradiation device will be used to receive miniplates of U{sub 3}O{sub 8}-Al e U{sub 3}Si{sub 2}-Al dispersion fuels, LEU type (19.9% of {sup 235}U), with uranium densities of, respectively, 3.0 gU/cm{sup 3} and 4.8gU/cm{sup 3}. The fuel miniplates will be irradiated to nominal {sup 235}U burnup levels of 50% and 80%, in order to qualify the above high-density dispersion fuels to be used in the Brazilian Multipurpose Reactor, now in the conception phase. For the neutronic calculation, the computer code CITATION was utilized. The computer code FLOW was used to calculate the coolant flow rate in the irradiation device, allowing the determination of the fuel miniplate temperatures with the computer model MTRCR-IEA-R1. A postulated Loss of Coolant Accident (LOCA) was analyzed with the computer codes LOSS and TEMPLOCA, allowing the calculation of the fuel miniplate temperatures after the reactor pool draining. The calculations showed that the irradiation of the fuel miniplates will happen without any adverse consequence in the IEA-R1 reactor. (author)

  4. Electrical in situ and post-irradiation properties of ceramics relevant to fusion irradiation conditions

    International Nuclear Information System (INIS)

    Shikama, Tatsuo; Zinkle, S.J.

    2002-01-01

    Electrical properties of ceramic candidate materials for the next-generation nuclear fusion devices under relevant irradiation conditions are reviewed. A main focal point is placed on the degradation behavior of the electrical insulating ability during and after irradiation. Several important radiation induced effects play important roles: radiation induced conductivity, thermally stimulated electrical conductivity, radiation induced electrical charge separation, and radiation induced electromotive force. These phenomena will interact with each other under fusion relevant irradiation conditions. The design of electrical components for the next-generation fusion devices should take into account these complicated interactions among the radiation induced phenomena

  5. Measuring irradiated lung and heart area in breast tangential fields using a simulator-based computerized tomography device

    International Nuclear Information System (INIS)

    Mallik, Raj; Fowler, Allan; Hunt, Peter

    1995-01-01

    Purpose: To illustrate the use of a simulator based computerized tomography system (SIMCT) in the simulation and planning of tangential breast fields. Methods and Materials: Forty-five consecutive patients underwent treatment planning using a radiotherapy simulator with computerized tomography attachment. One to three scans were obtained for each patient, calculations were made on the central axis scan. Due to the wide aperture of this system all patients were able to be scanned in the desired treatment position with arm abducted 90 deg. . Using available software tools the area of lung and/or heart included within the tangential fields was calculated. The greatest perpendicular distance (GPD) from the chest wall to posterior field edge was also measured. Results: The mean GPD for the group was 25.40 mm with 71% of patients having GPDs of ≤ 30 mm. The mean area of irradiated lung was 1780 sq mm which represented 18.0% of the total ipsilateral lung area seen in the central axis. Seven of the patients with left sided tumors had an average 1314 sq mm heart irradiated in the central axis. This represented 11.9% of total heart area in these patients. Conclusion: Measurements of irradiated lung and heart area can be easily and accurately made using a SIMCT device. Such measurements may help identify those patients potentially at risk for lung or heart toxicity as a consequence of their treatment. A major advantage of this device is the ability to scan patients in the actual treatment position

  6. Measuring irradiated lung and heart area in breast tangential fields using a simulator-based computerized tomography device

    Energy Technology Data Exchange (ETDEWEB)

    Mallik, Raj; Fowler, Allan; Hunt, Peter

    1995-01-15

    Purpose: To illustrate the use of a simulator based computerized tomography system (SIMCT) in the simulation and planning of tangential breast fields. Methods and Materials: Forty-five consecutive patients underwent treatment planning using a radiotherapy simulator with computerized tomography attachment. One to three scans were obtained for each patient, calculations were made on the central axis scan. Due to the wide aperture of this system all patients were able to be scanned in the desired treatment position with arm abducted 90 deg. . Using available software tools the area of lung and/or heart included within the tangential fields was calculated. The greatest perpendicular distance (GPD) from the chest wall to posterior field edge was also measured. Results: The mean GPD for the group was 25.40 mm with 71% of patients having GPDs of {<=} 30 mm. The mean area of irradiated lung was 1780 sq mm which represented 18.0% of the total ipsilateral lung area seen in the central axis. Seven of the patients with left sided tumors had an average 1314 sq mm heart irradiated in the central axis. This represented 11.9% of total heart area in these patients. Conclusion: Measurements of irradiated lung and heart area can be easily and accurately made using a SIMCT device. Such measurements may help identify those patients potentially at risk for lung or heart toxicity as a consequence of their treatment. A major advantage of this device is the ability to scan patients in the actual treatment position.

  7. Effects of 6 MeV electron irradiation on the electrical properties and device parameters of Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si MOS capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Laha, P.; Banerjee, I.; Barhai, P.K. [Department of Applied Physics, Birla Institute of Technology, Mesra, Ranchi 835215 (India); Das, A.K. [Laser and Plasma Technology Division, Bhabha Atomic Research Center, Mumbai 400085 (India); Bhoraskar, V.N. [Department of Physics, University of Pune, Ganeshkhind, Pune 411007 (India); Mahapatra, S.K., E-mail: skm@physics.ucla.edu [Department of Applied Physics, Birla Institute of Technology, Mesra, Ranchi 835215 (India)

    2012-07-15

    Highlights: Black-Right-Pointing-Pointer The electron irradiation effects make variation in the device parameters. Black-Right-Pointing-Pointer The device parameters changes due to percentage of defects and charge trapping. Black-Right-Pointing-Pointer Leakage current of Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si changes due to interface dangling bonds. Black-Right-Pointing-Pointer The leakage current mechanism of MOS structures is due to Poole-Frenkel effect. - Abstract: The effects of 6 MeV electron irradiation on the electrical properties and device parameter characteristics of Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si metal-oxide-semiconductor capacitors have been studied. Twelve Al/Al{sub 2}O{sub 3}/TiO{sub 2}/n-Si MOS capacitors were fabricated using r.f. magnetron sputtering and divided into four groups. The first group was not irradiated and treated as virgin. The rest were irradiated with 6 MeV electrons at doses 10, 20, and 30 kGy, maintaining the dose rate at {approx}1 kGy/min. Variations in crystallinity of the virgin and irradiated capacitors were studied using grazing incident X-ray diffraction. The thickness and in-depth elemental distributions of individual layers were determined using secondary ion mass apectrometry. Capacitance-voltage, conductance-voltage and leakage current-voltage characteristics of the virgin and irradiated samples were studied. The device parameters (flat band voltage, surface charge density and interface trap density of the virgin and irradiated structures) were determined. The electrical properties of the capacitors were investigated and the Poole-Frenkel coefficient of the capacitors was determined from leakage current measurements. The leakage current mechanism has been explained.

  8. Study on preparation of 166Ho-Chitosan oriented in the treatment of liver cancer

    International Nuclear Information System (INIS)

    Dang Ho Hong Quang; Duong Van Dong; Bui Van Cuong; Nguyen Thanh Binh; Nguyen Thanh Nhan; Nguyen Dinh Lam; Nguyen Thi Thu

    2017-01-01

    This study describes the process for the preparation and quality control of 166 Ho-Chitosan product. The labeling conditions of chitosan with 166 Ho radioisotope were carried out such as the concentration of chitosan, pH, temperature and reaction time to create 166 Ho-Chitosan compositions. Product quality inspection 166 Ho-Chitosan on the criteria as nuclide purity, radiochemical purity, tested for sterility and bacterial endotoxin. The results of survey showed that 166 Ho labeled with chitosan were completed in 1% acetic acid, 3 mCi: 30 mg ratio at pH = 3, marking time at room temperature for 30 minutes. The results of quality test have shown radionuclide purity ≥ 99%, radiochemical purity ≥ 98%, meeting the criteria for the aseptic and bacterial endotoxin according to IV Vietnam pharmacopoeia. From the above mentioned, 166 Ho-Chitosan compositions meet the quality criteria of the radiopharmaceuticals, therefore, it can be used in pre-clinical research and its application in clinical treatment. (author)

  9. Animal experiments and clinical trials of {sup 166}Ho-chitosan for various cancers

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sang Moo; Choi, C W; Kim, E H; Woo, K S; Chung, W S; Lee, J I; Park, S Y; Son, Y S; Lee, S H; Kim, S J; Kim, B G; Kim, J H; Lee, C H [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1997-07-01

    {sup 166}Ho is a good therapeutic radionuclide because of its suitable half-life (26.8 hours), high beta energy and 6% gamma ray for imaging. Chitosan is a kind of N-glucosamine with 400 to 500 kD MW, which chelates metal ions and degrades slowly in vivo. As a preclinical studies, we performed cytotoxic effect of {sup 166}Ho-chitosan in a variety of cancer cell lines derived from stomach or ovarian cancer based on MTT assay and HTCA method. To evaluated the absorbed dose to the cavitary wall from {sup 166}Ho-chitosan, intraperitoneal administration of {sup 166}Ho-chitosan in the rat and simulation of energy transfer from the beta particles to the cavity wall using the Monte Carlo code EGS4 was done, and used as a standard for the planning therapy. Intracavitary {sup 166}Ho-chitosan therapy were tried in peritoneal metastatic ovarian and stomach cancers and cystic brain tumors. Intraarterial injection in inoperable primary liver cancer was also tried. As a radiation synovectomy agent, biocompatibility study in the knee joints of rabbits were performed. {sup 166}Ho-chitosan showed synergistic effects with 5-FU or cisplatin in vitro. 97-99% of {sup 166}Ho-chitosan was localized within the peritoneal cavity, and more than 90% of {sup 166}Ho-chitosan was attached to the peritoneal wall. Partial response were observed in 4 among 5 patients with ovarian cancer without severe toxicity. In the cystic brain tumor, 5 of 8 cysts were shrunken in size with thinning of the wall, 2 out of 8 showed growth retardation. In the primary liver cancer, radioactivity was distributed in the teritory of selected hepatic arterial branch, and partial responses were observed in 2 cases. In the knee joints of the rabbits, more than 98% of {sup 166}Ho-chitosan remained in the joint cavity and was stable upto 1 week. 49 refs., 22 tabs. (author)

  10. Dosimetry work and calculations in connection with the irradiation of large devices in the high flux materials testing reactor BR2

    International Nuclear Information System (INIS)

    De Raedt, C.; Leenders, L.; Tourwe, H.; Farrar, H. IV.

    1982-01-01

    For about fifteen years the high flux reactor BR2 has been involved in the testing of fast reactor fuel pins. In order to simulate the fast reactor neutron environment most devices are irradiated under cadmium screen, cutting off the thermal flux component. Extensive neutronic calculations are performed to help the optimization of the fuel bundle design. The actual experiments are preceded by irradiations of their mock-ups in BR02, the zero power model of BR2. The mock-up irradiations, supported by supplementary calculations, are performed for the determination of the main neutronic characteristics of the irradiation proper in BR2 and for the determination of the corresponding operation data. At the end of the BR2 irradiation, the experimental results, such as burn-ups, neutron fluences, helium production in the fuel pin claddings, etc. are correlated by neutronic calculations in order to examine the consistency of the post-irradiation results and to validate the routine calculation procedure and cross-section data employed. A comparison is made in this paper between neutronic calculation results and some post-irradiation data for MOL 7D, a cadmium screened sodium cooled loop containing a nineteen fuel pin bundle

  11. 36 CFR 13.166 - Temporary facilities.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Temporary facilities. 13.166... facilities. A temporary facility or structure directly and necessarily related to the taking of subsistence... facilities which shall be published annually in accordance with § 1.7 of this chapter. ...

  12. 25 CFR 166.608 - What types of insurance may be required?

    Science.gov (United States)

    2010-04-01

    ... Bonding and Insurance Requirements § 166.608 What types of insurance may be required? We may require liability or casualty insurance (such as for fire, hazard, or flood), depending upon the activity conducted... 25 Indians 1 2010-04-01 2010-04-01 false What types of insurance may be required? 166.608 Section...

  13. Hot-carrier effects on irradiated deep submicron NMOSFET

    International Nuclear Information System (INIS)

    Cui Jiangwei; Zheng Qiwen; Yu Xuefeng; Cong Zhongchao; Zhou Hang; Guo Qi; Wen Lin; Wei Ying; Ren Diyuan

    2014-01-01

    We investigate how γ exposure impacts the hot-carrier degradation in deep submicron NMOSFET with different technologies and device geometries for the first time. The results show that hot-carrier degradations on irradiated devices are greater than those without irradiation, especially for narrow channel device. The reason is attributed to charge traps in STI, which then induce different electric field and impact ionization rates during hot-carrier stress. (semiconductor devices)

  14. 33 CFR 165.166 - Safety Zone: Macy's July 4th Fireworks, East River, NY.

    Science.gov (United States)

    2010-07-01

    ... Fireworks, East River, NY. 165.166 Section 165.166 Navigation and Navigable Waters COAST GUARD, DEPARTMENT... § 165.166 Safety Zone: Macy's July 4th Fireworks, East River, NY. (a) Regulated area. The following area...) in length, carrying persons for the purpose of viewing the fireworks, may take position in an area...

  15. Isomer-delayed gamma-ray spectroscopy of neutron-rich 166Tb

    Directory of Open Access Journals (Sweden)

    Gurgi L.A.

    2017-01-01

    Full Text Available This short paper presents the identification of a metastable, isomeric-state decay in the neutron-rich odd-odd, prolate-deformed nucleus 166Tb. The nucleus of interest was formed using the in-flight fission of a 345 MeV per nucleon 238U primary beam at the RIBF facility, RIKEN, Japan. Gamma-ray transitions decaying from the observed isomeric states in 166Tb were identified using the EURICA gamma-ray spectrometer, positioned at the final focus of the BigRIPS fragments separator. The current work identifies a single discrete gamma-ray transition of energy 119 keV which de-excites an isomeric state in 166Tb with a measured half-life of 3.5(4 μs. The multipolarity assignment for this transition is an electric dipole and is made on the basis internal conversion and decay lifetime arguments. Possible two quasi-particle Nilsson configurations for the initial and final states which are linked by this transition in 166Tb are made on the basis of comparison with Blocked BCS Nilsson calculations, with the predicted ground state configuration for this nucleus arising from the coupling of the v(1-/2[521] and π(3+/2 Nilsson orbitals.

  16. Standardization Of 166mHo Using Merlin Gerin Ionization Chamber System

    International Nuclear Information System (INIS)

    Nazaroh; Chandra; Hermawan; Juita Erni

    2000-01-01

    Standardization of 166m Ho using Merlin Gerin ionization chamber system has been carried out. Solution of 166m Ho was obtained from ETL-Japan. Activity measurement of 166m Ho was done before and after preparation. The result of activity measurement by P3KRBiN before preparation was (134.47±0.4) kBq/g, and after preparation was (131.98±1.85) kBq/g, at reference time, 1 March 1999. The ETL's result was (130.4±0.4) kBq/g, at the same reference time. The difference between P3KRBiN's (without uncertainty) and ETL's measurement result was 1.2% and if the uncertainty was included, both measurements was agreed

  17. Transurethral lithotripsy with holmium-YAG laser of a large exogenous prostatic calculus.

    Science.gov (United States)

    Hasegawa, Masanori; Ohara, Rei; Kanao, Kent; Nakajima, Yosuke

    2011-04-01

    Prostatic calculi are classified into two types, endogenous and exogenous calculi, based on their origin. Endogenous calculi are commonly observed in elderly men; however, exogenous prostatic calculi are extremely rare. We report here the case of a 51-year-old man who suffered incontinence and pollakiuria with a giant exogenous prostatic calculus almost completely replacing the prostatic tissue. X-rays and computed tomography demonstrated a large calculus of 65 × 58 mm in the small pelvic cavity. The patient underwent a transurethral lithotripsy with a holmium-YAG laser and a total of 85 g of disintegrated stones was retrieved and chemical stone analysis revealed the presence of magnesium ammonium phosphate. The incontinence improved and the voiding volume increased dramatically, and no stone recurrence in the prostatic fossa occurred at the 2 years follow-up. The etiology of this stone formation seemed to be based on some exogenous pathways combined with urinary stasis and chronic urinary infection due to compression fracture of the lumbar vertebra.

  18. Using TRIGA Mark II research reactor for irradiation with thermal neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kolšek, Aljaž, E-mail: aljaz.kolsek@gmail.com; Radulović, Vladimir, E-mail: vladimir.radulovic@ijs.si; Trkov, Andrej, E-mail: andrej.trkov@ijs.si; Snoj, Luka, E-mail: luka.snoj@ijs.si

    2015-03-15

    Highlights: • Monte Carlo N-Particle Transport Code was used to design and perform calculations. • Characterization of the TRIGA Mark II ex-core irradiation facilities was performed. • The irradiation device was designed in the TRIGA irradiation channel. • The use of the device improves the fraction of thermal neutron flux by 390%. - Abstract: Recently a series of test irradiations was performed at the JSI TRIGA Mark II reactor for the Fission Track-Thermoionization Mass Spectrometry (FT-TIMS) method, which requires a well thermalized neutron spectrum for sample irradiation. For this purpose the Monte Carlo N-Particle Transport Code (MCNP5) was used to computationally support the design of an irradiation device inside the TRIGA model and to support the actual measurements by calculating the neutron fluxes inside the major ex-core irradiation facilities. The irradiation device, filled with heavy water, was designed and optimized inside the Thermal Column and the additional moderation was placed inside the Elevated Piercing Port. The use of the device improves the ratio of thermal neutron flux to the sum of epithermal and fast neutron flux inside the Thermal Column Port by 390% and achieves the desired thermal neutron fluence of 10{sup 15} neutrons/cm{sup 2} in irradiation time of 20 h.

  19. 40 CFR 166.32 - Reporting and recordkeeping requirements for specific, quarantine, and public health exemptions.

    Science.gov (United States)

    2010-07-01

    ... requirements for specific, quarantine, and public health exemptions. 166.32 Section 166.32 Protection of... AGENCIES FOR USE OF PESTICIDES UNDER EMERGENCY CONDITIONS Specific, Quarantine, and Public Health Exemptions § 166.32 Reporting and recordkeeping requirements for specific, quarantine, and public health...

  20. Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of Ho-166 Microspheres in Liver Radioembolization

    NARCIS (Netherlands)

    Seevinck, Peter R.; van de Maat, Gerrit H.; de Wit, Tim C.; Vente, Maarten A. D.; Nijsen, Johannes F. W.; Bakker, Chris J. G.

    2012-01-01

    Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional Ho-166 activity distribution to estimate radiation-absorbed dose distributions in Ho-166-loaded poly (L-lactic acid) microsphere (Ho-166-PLLA-MS) liver radioembolization.

  1. Development of radioactive 166Ho-coated balloon and its dose estimation

    International Nuclear Information System (INIS)

    Park, K. B.; Kim, K. H.; Hong, Y. D.; Park, E. W.

    2000-01-01

    The use of balloon with radioisotope is a promising method to prevent restenosis after transluminal coronary arterial angioplasty or stent implantation. In this study, we have developed a new radioactive coated balloon, which is prepared by coating the surface of existing balloon with 166 Ho instead of being filled with beta sources which emit high energy beta-particles for the purpose of the delivery of sufficient radiation to the vessel wall. To estimate the safety of 166 Ho-coated balloon, leaching test and radiation resistance test of the balloon were performed. The absorbed dose distributions around the 166 Ho-coated balloon were estimated by means of Monte Carlo simulation and the initial activities for optimal therapeutic regimen were determined on the basis of this results

  2. New therapeutic agent for radiation synovectomy - preparation of 166Ho-EDTMP-HA particle

    International Nuclear Information System (INIS)

    Bai, H.; Jin, X.; Du, J.; Wang, F.; Chen, D.; Fan, H.; Cheng, Z.; Zhang, J.

    1997-01-01

    In order to prepare new therapeutical agent for radiation synovectomy, Hydroxyapatite (HA) was labelled with 166 Ho by EDTMP that had high affinity to HA particles. Radiolabelling of HA particles was divided into two steps, 166 Ho-EDTMP was prepared first; then mixed with HA particles completely and vibrated for 15 minutes on the micromixer at room temperature, washed 3 times with deionized water. Radiolabelling particle was separated from free 166 Ho via centrifugation to determine its radiolabelling efficiency. 166 Ho-EDTMP-HA and 166 Ho-EDTMP were injected into knee joint of normal rabbits respectively, every group was killed at different time postinjection, took out major organ and collected urine and blood, then weighted and determined their radio counts. HA particles, as a natural component of bone was known to have good compatibility with soft tissue and biodegrade into calcium and phosphate in vivo. It was readily prepared from common chemical and formed into particles of desired size range in a controlled process, it had high stability in vitro and vivo. Radiolabelling of HA particle with 166 Ho by EDTMP was simple to perform and provides an excellent labelling yield that was more than 95% under the optimal labelling condition. The optimal labelling condition at room temperature was pH 6.0-8.0 and vibration time 15 minutes. The absorbed capacity of HA particle was 5 mg Ho/g HA particle and size of radiolabelling particle was at range of 2-5,μm that is suitable for therapy of radiation synovectomy. 166 Ho-EDTMP-HA particle demonstrated high in vitro stability in either normal saline or 1% BSA solution, but instability under extremely acidic condition (pH 1-2). The control studies performed with 166 Ho-EDTMP not bound to HA particle provided information on the distribution of radioactivity that would occur upon leakage of the radiochemical compound from joint. Its short half-life, its extremely low leakage from the joint and its even distribution throughout

  3. Development of blood irradiators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This project is designed to improve the techniques of blood irradiation through the development of improved and portable blood irradiators. A portable blood irradiator, consisting of a vitreous carbon body and thulium-170 radiation source, was attached to dogs via a carotid-jugular shunt, and its effects on the immune system measured. The device has demonstrated both significant suppression of circulating lymphocytes and prolonged retention of skin allografts

  4. Impact of neutron irradiation on thermal helium desorption from iron

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Xunxiang, E-mail: hux1@ornl.gov [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Field, Kevin G. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Taller, Stephen [University of Michigan, Ann Arbor, MI 48109 (United States); Katoh, Yutai [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Wirth, Brian D. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); University of Tennessee, Knoxville, TN 37996 (United States)

    2017-06-15

    The synergistic effect of neutron irradiation and transmutant helium production is an important concern for the application of iron-based alloys as structural materials in fission and fusion reactors. In this study, we investigated the impact of neutron irradiation on thermal helium desorption behavior in high purity iron. Single crystalline and polycrystalline iron samples were neutron irradiated in HFIR to 5 dpa at 300 °C and in BOR-60 to 16.6 dpa at 386 °C, respectively. Following neutron irradiation, 10 keV He ion implantation was performed at room temperature on both samples to a fluence of 7 × 10{sup 18} He/m{sup 2}. Thermal desorption spectrometry (TDS) was conducted to assess the helium diffusion and clustering kinetics by analyzing the desorption spectra. The comparison of He desorption spectra between unirradiated and neutron irradiated samples showed that the major He desorption peaks shift to higher temperatures for the neutron-irradiated iron samples, implying that strong trapping sites for He were produced during neutron irradiation, which appeared to be nm-sized cavities through TEM examination. The underlying mechanisms controlling the helium trapping and desorption behavior were deduced by assessing changes in the microstructure, as characterized by TEM, of the neutron irradiated samples before and after TDS measurements.

  5. Investigation of corrosion of materials of the irradiation device in the RA reactor

    International Nuclear Information System (INIS)

    Zaric, M.; Mance, A.; Vlajic, M.

    1963-12-01

    Devices for sample irradiation in the vertical RA reactor channels will be made of aluminium alloys. According to the regulations concerned with introducing materials into the RA reactor core, corrosion characterisation of these materials is an obligation. Corrosion properties of four aluminium alloys were investigated both in contact with stainless steel and without it. First part of this report deals with the corrosion testing of aluminium alloys in water by gravimetric and electrochemical methods. Bi-distilled water at temperatures less than 100 deg C was used. Second part is related to aluminium alloys corrosion in carbon dioxide gas under experimental conditions. The second part of research was initiated by the design of the head of the independent CO 2 loop for samples cooling [sr

  6. Design of device for testing in the gamma irradiator; Diseno de dispositivo para pruebas en el irradiador gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-02-15

    In eves of the recharge of the Gamma Irradiator, JS-6500 it was detected, that there was contamination in the container that housed the pencils of Co-60, coming from Argentina, country to which the ININ buys it recharges. It was determined that the contamination in the container was it interns and after discussing several solution options it was determined to manufacture a device to make a washing of the pencils. It was touch to the Management of Radiological Safety to determine the conceptual design of the device to make the washing and the way of operation of the same one. The Management of Prototypes and Models was responsibility of the mechanical design and its production. (Author)

  7. Irradiation techniques at BR2 reactor

    International Nuclear Information System (INIS)

    Hebel, W.

    1978-01-01

    Since 1963 the material testing reactor BR2 at Mol is operated for the realisation of numerous research programs and experiments on the behavior of materials under nuclear radiation and in particular under intensive neutron exposure. During this period special irradiation techniques and experimental devices were developed according to the desiderata of the different experiments and to the irradiation possibilities offered at BR2. The design and the operating characteristics of quite a number of those irradiation rigs of proven reliability may be used or can be made available for new irradiation experiments. A brief description is given of some typical irradiation devices designed and constructed by CEN/SCK, Technology and Energy Dpt. They are compiled according to their main use for the different research and development programs realized at BR2. Their eventual application however for different objectives could be possible. A final chapter summarizes the principal irradiation conditions offered by BR2 reactor. (author)

  8. 25 CFR 166.901 - How will the BIA select an agriculture intern?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false How will the BIA select an agriculture intern? 166.901... PERMITS Agriculture Education, Education Assistance, Recruitment, and Training § 166.901 How will the BIA select an agriculture intern? (a) The purpose of the agriculture intern program is to ensure the future...

  9. Development of a PET tracer for imaging EGFR tyrosine kinase: evaluation of the suitability of PKI166

    International Nuclear Information System (INIS)

    Kernchen, R.; Brust, P.; Krause, M.; Baumann, M.

    2002-01-01

    The suitability of PKI166 for the development of a PET tracer for imaging EGFR tyrosine kinase was investigated. Binding studies using EGFR positive tumour tissue and tritiated PKI166 as the radioligand indicated a low binding affinity of PKI166 to the target tissue. PKI166 is therefore not recommended for PET tracer development. (orig.)

  10. Qualification of the on-line power determination of fuel elements in irradiation devices in the BR2 reactor

    International Nuclear Information System (INIS)

    Vermeeren, L.; Dekeyser, J.; Gouat, P.; Kalcheva, S.; Koonen, E.; Kuzminov, V.; Verwimp, A.; Weber, M.

    2005-01-01

    Fuel irradiation tests require an on-line monitoring of the fuel power. In the BR2 reactor, this is performed by continuously measuring the enthalpy change in the coolant of the irradiation device and complementing this information with data on power losses, heating of structure parts and spatial power profiles from mock-up test experiments and from calculations. Since a few years Monte Carlo codes (MCNP) are used, describing the BR2 core in great detail for every reactor cycle with its specific core load, yielding not only reliable relative values, but also calculated absolute local power values in agreement with data from PIE analyses. Several methods were conceived to combine the experimental and calculated data for the on-line calculation of the local linear power in the fuel elements; their internal consistency and the consistency with gamma spectroscopy data and data from radiochemical fission product analysis was checked. The data show that fuel irradiations in BR2 can be performed in a well-controlled way, with an accurate and reliable on-line follow-up of the fuel power. (author)

  11. Irradiation of carabao mangoes for decay control

    International Nuclear Information System (INIS)

    Alabastro, E.F.; Pineda, A.S.; Pangan, A.C.; Valle, M.J. del.

    Control of postharvest diseases of carabao mangoes by gamma radiation has been the subject of several local studies, notably that of Herrera and Valencia (1964) and Pablo et al (1971) which showed dose levels of 16.6 Kr. and 60 Kr. respectively, to be effective in extending the market life. The wide range of resorted effective dose levels for mangoes prompted this investigation which aimed to establish the pre-dominant spoilage-causing micro-organisms and the effectivity of irradiation in controlling or delaying the growth of these micro-organisms. (author)

  12. 25 CFR 1000.166 - What are the phases of the negotiation process?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 2 2010-04-01 2010-04-01 false What are the phases of the negotiation process? 1000.166 Section 1000.166 Indians OFFICE OF THE ASSISTANT SECRETARY, INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ANNUAL FUNDING AGREEMENTS UNDER THE TRIBAL SELF-GOVERNMENT ACT AMENDMENTS TO THE INDIAN SELF-DETERMINATION AND EDUCATION ACT Negotiation Process...

  13. Influence of crystallite size and temperature on the antiferromagnetic helices of terbium and holmium metal

    Energy Technology Data Exchange (ETDEWEB)

    Bick, Jens-Peter; Michels, Andreas [Universitaet des Saarlandes, D-66041 Saarbruecken (Germany); University of Luxembourg, L-1511 Luxembourg (Luxembourg); Ferdinand, Adrian; Birringer, Rainer [Universitaet des Saarlandes, D-66041 Saarbruecken (Germany); Baller, Joerg; Sanctuary, Roland [University of Luxembourg, L-1511 Luxembourg (Luxembourg); Philippi, Stefan [Leibniz Institute for Solid State and Materials Research, D-01069 Dresden (Germany); Lott, Dieter [GKSS Research Center, D-21502 Geesthacht (Germany); Balog, Sandor [Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Rotenberg, Eli [Lawrence Berkeley National Laboratory, California 94720 (United States); Kaindl, Guenter [Freie Universitaet Berlin, D-14195 Berlin-Dahlem (Germany); Doebrich, Kristian M. [Freie Universitaet Berlin, D-14195 Berlin-Dahlem (Germany); Max-Born-Institut, D-12489 Berlin (Germany)

    2011-07-01

    We report on the results of grain-size and temperature-dependent magnetization, specific-heat, neutron-scattering, and angle-resolved photoelectron spectroscopy (ARPES) experiments on the heavy rare-earth metals terbium and holmium, with particular emphasis on the temperature regions where the helical antiferromagnetic phases exist. In contrast to Ho, we find that the helical structure in Tb is relative strongly affected by microstructural disorder, specifically, it can no longer be detected for the smallest studied grain size of D=18 nm. Moreover, in coarse-grained Tb a helical structure persists even in the ferromagnetic regime, down to about T=215 K, in agreement with the ARPES data, which reveal a nesting feature of the Fermi surface at the L point of the Brillouin zone at T=210 K.

  14. The present situation of irradiation services

    International Nuclear Information System (INIS)

    Hironiwa, Takayuki

    2014-01-01

    The present state of food irradiation in Japan is presented from a point of view of a trustee for irradiation business. Radiation sprout inhibition of potatoes, only approved by Government, and spice treatment, now being applied for, are explained. Existing establishments capable of entrusting irradiation services as business in Japan are outlined including Co-60 gamma ray and X-ray irradiation and electron beam irradiation. Principles of irradiation-induced physical and chemical effects in irradiated materials specifically organic polymers and brief explanation of facilities together with safety devices are also explained. (S. Ohno)

  15. Clinical study of liver cancer (Hepatocellular carcinoma) by 166 Ho-CHICO

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. T.; Yoo, H. S.; Lee, J. D.; Lee, D. Y.; Kim, E. K.; Yoo, N. C.; Shin, S. J.; Han, K. H. [Yonsei University, Seoul (Korea); Park, K. B. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-04-01

    As having used Ho-166 Chitosan complex, this study was designed for the development of new therapeutic agent in the treatment of liver cancer (hepatocellular carcinoma). During the period of 3 years from April 1, 1997 to March 31, 2000, this project was successfully performed on the base of clinical experience with percutaneous Ho-166 CHICO injection in the treatment of liver cancer'. In order to evaluate the biodistribution and effect of Ho-166 CHICO was performed in 50 patients, who had the progressed liver cancer with range of 3-10cm in diameter. After the administration of the complex materials, we evaluated the therapeutic effect as well as complication by the follow-up study that included laboratory examination, radioactivity counting and various imaging modalities. 1) In animal experiment, radioactivity of target liver was ranged between 27-33% of total body one, urine excretion between 0.17-0.24 %. White blood cell and platelet counts start diminishing within 7 days and at maximum within 4 weeks after administration of complex materials. In tissue changes of target liver was revealed no significant change in the tumor dose of Ho-166, but periportal fibrosis and massive tissue necrosis in the high ones. 2) In clinical study, total necrosis of tumor is 66%, partial 10% and non-response 24% among 50 patients' liver cancer. The most important complication were leukopenia and thrombocytopenia (82%), the remained was abdominal pain(34%), skin reaction(12%), bile duct obstruction(10%), liver abscess(6%) etc. Conclusively intraarterial injection of Ho-166 CHICO was effective in the treatment of larger and progressed liver cancer. 19 refs., 14 figs., 8 tabs. (Author)

  16. Thermodynamic properties of the neutral and ionic components of the holmium trichloride vapor

    International Nuclear Information System (INIS)

    Kuznetsov, A.Yu.; Kudin, L.S.; Pogrebnoj, A.M.; Butman, M.F.; Burdukovskaya, G.G.

    1999-01-01

    The composition of saturated vapor above holmium trichloride in the temperature range of 887 - 1051 K is studied by the method of high-temperature mass spectrometry. Neutral components are presented by molecules of Ho n Cl 3n , n = 1 - 4 charged ones - by Cl - , HoCl 4 - , Ho 2 Cl 7 - ions. Sublimation enthalpies and formation enthalpies of gaseous molecules and ions (298 K): Δ s H Deg (HoCl 3 ) = 284 ±6, Δ s H Deg (Ho 2 Cl 6 ) = 352 ± 20; ΔH Deg (HoCl 3 ) = -722 ± 6; Δ f H Deg (Ho 2 Cl 6 ) = -1661 ± 20; Δ f H Deg (HoCl 4 - ) ≤ - 1191 ± 20, Δ f H Deg (Ho-2Cl 7 - ) ≤ -2127 ± 30 kJ/mol are determined. The value of electron affinity for HoCl 4 radical (A 0 ≥ 3.6 eV) is estimated [ru

  17. 27 CFR 555.166 - Seizure or forfeiture.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 3 2010-04-01 2010-04-01 false Seizure or forfeiture. 555... EXPLOSIVES, DEPARTMENT OF JUSTICE EXPLOSIVES COMMERCE IN EXPLOSIVES Unlawful Acts, Penalties, Seizures and Forfeitures § 555.166 Seizure or forfeiture. Any explosive materials involved or used or intended to be used...

  18. 25 CFR 166.220 - What are the basic steps for acquiring a permit through negotiation?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false What are the basic steps for acquiring a permit through negotiation? 166.220 Section 166.220 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER GRAZING PERMITS Permit Requirements Obtaining A Permit § 166.220 What are the basic steps for acquiring a permit through negotiation? The...

  19. Hyperfine-Interaction-Driven Suppression of Quantum Tunneling at Zero Field in a Holmium(III) Single-Ion Magnet.

    Science.gov (United States)

    Chen, Yan-Cong; Liu, Jun-Liang; Wernsdorfer, Wolfgang; Liu, Dan; Chibotaru, Liviu F; Chen, Xiao-Ming; Tong, Ming-Liang

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm -1 . The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from 165 Ho (I=7/2) with a natural abundance of 100 %. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Establishment of experimental equipments in irradiation technology development building (2)

    International Nuclear Information System (INIS)

    Shibata, Hiroshi; Nakano, Hiroko; Suzuki, Yoshitaka; Ohtsuka, Noriaki; Nishikata, Kaori; Takeuchi, Tomoaki; Hirota, Noriaki; Tsuchiya, Kunihiko

    2018-01-01

    From the viewpoints of utilization improvement of the Japan Materials Testing Reactor (JMTR), the experimental devices have been established for the out-pile tests in the irradiation technology development building. The devices for the irradiation capsule assembly, material tests and inspections were established at first and experimental data were accumulated before the neutron irradiation tests. On the other hand, after the Great East Japan Earthquake, the repairs and earthquake-resistant measures of the existing devices were carried out. New devices and equipments were also established for the R and D program for power plant safety enhancement of the Agency for Natural Resources and Energy, Ministry of Economy, Trade and Industry (METI) and 99 Mo/ 99m Tc production development under the Tsukuba International Strategic Zone. This report describes the outline and basic operation manuals of the devices established from 2011 to 2016 and the management points for the safety works in the irradiation technology development building. (author)

  1. Holmium laser lithotripsy (HoLL) of ureteral calculi

    Science.gov (United States)

    Kuntz, Rainer M.; Lehrich, Karin; Fayad, Amr

    2001-05-01

    The effectiveness and side effects of ureteroscopic HoLL of ureteral stones should be evaluated. In 63 patients (17 female, 46 males) a total of 75 stones of 3-20 mm diameter were treated with ureteroscopic HoLL. 18.7 percent of stones were located in the proximal third, 24.0 percent in the middle third and 57.3 percent in the distal third of the ureter. HoLL was performed with small diameter semirigid and flexible ureteroscopes, 220 or 365 nm flexible laser fibers and a holmium:YAG laser at a power of 5-15 W (0.5-1.0 J, 10- 15 Hz). 47 of 63 patients (74.6 percent) were immediately free of stones, and 8 others (12.6 percent) lost their residual fragments spontaneously within two weeks. Another 2 patients received additional chmolitholysis for uric acid stone fragments, i.e. 90.5 percent of patients were stone free by one sitting of ureterscopic HoLL. Of the remaining 6 patients (9.5 percent) who still had residual calculi 4 weeks after HoLL, 2 asymptomatic patients refused any additional treatment, 2 patients preferred treatment with ESWL, and 2 patients had a successful second HoLL, thereby raising the success rate of ureteroscopic HoLL to 93.7 percent. 2 patients showed contrast medium extravasation on retrograde ureterograms, due to guide wire perforation. No ureteral stricture occurred. In conclusion, transurethral ureteroscopic HoLL proved to be a safe and successful minimal invasive treatment of ureteral calculi.

  2. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  3. Development of irradiation support devices for production of brachytherapy seeds

    International Nuclear Information System (INIS)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G.

    2013-01-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  4. Dose Distribution of Gamma Irradiators

    International Nuclear Information System (INIS)

    Park, Seung Woo; Shin, Sang Hun; Son, Ki Hong; Lee, Chang Yeol; Kim, Kum Bae; Jung, Hai Jo; Ji, Young Hoon

    2010-01-01

    Gamma irradiator using Cs-137 have been widely utilized to the irradiation of cell, blood, and animal, and the dose measurement and education. The Gamma cell 3000 Elan (Nordion International, Kanata, Ontario, Canada) irradiator was installed in 2003 with Cs-137 and dose rate of 3.2 Gy/min. And the BioBeam 8000 (Gamma-Service Medical GmbH, Leipzig, Germany) irradiator was installed in 2008 with Cs-137 and dose rate of 3.5 Gy/min. Our purpose was to evaluate the practical dosimetric problems associated with inhomogeneous dose distribution within the irradiated volume in open air state using glass dosimeter and Gafchromic EBT film dosimeter for routine Gamma irradiator dosimetry applications at the KIRAMS and the measurements were compared with each other. In addition, an user guideline for useful utilization of the device based on practical dosimetry will be prepared. The measurement results of uniformity of delivered dose within the device showed variation more than 14% between middle point and the lowest position at central axis. Therefore, to maintain dose variation within 10%, the criteria of useful dose distribution, for research radiation effects, the irradiated specimen located at central axis of the container should be placed within 30 mm from top and bottom surface, respectively. In addition, for measurements using the film, the variations of dose distribution were more then 50% for the case of less than 10 second irradiation, mostly within 20% for the case of more than 20 second irradiation, respectively. Therefore, the irradiation experiments using the BioBeam 8000 irradiator are recommended to be used for specimen required at least more than 20 second irradiation time.

  5. Studies on γ-irradiation-induced-degradation of chloramphenicol in aqueous solution

    International Nuclear Information System (INIS)

    Xie Fang; Ha Yiming; Wang Feng; Zhou Hongjie

    2008-01-01

    The irradiation-induced degradation of chloramphenicol by γ-rays in aqueous solution was studied and the radiolytical products were determined. The relationship among degradation rate, absorbed dose and initial concentration have been explored by comparing the position of maximum absorption peaks of chloramphenicol be- fore and after irradiation using high performance liquid chromatography. The identification of radiolytical products has been conducted using liquid chromatography tandem mass spectrometry. It has been found that the relationship among C/C 0 , absorbed dose and initial concentration can be fit with index curve. After irradiation, more than 30 radiolytical products with stable absorption below 278nm could be determined. 8 major radiolytical products with [M-H] - 353, 337, 335(A), 335(B), 319, 289, 127, 166, which are detected in several different conditions, have been picked up. Their possible structures are deducted. (authors)

  6. Design, fabrication and transportation of Si rotating device

    International Nuclear Information System (INIS)

    Kimura, Nobuaki; Imaizumi, Tomomi; Takemoto, Noriyuki; Tanimoto, Masataka; Saito, Takashi; Hori, Naohiko; Tsuchiya, Kunihiko; Romanova, Nataliya; Gizatulin, Shamil; Martyushov, Alexandr; Nakipov, Darkhan; Chakrov, Petr; Tanaka, Futoshi; Nakajima, Takeshi

    2012-06-01

    Si semiconductor production by Neutron Transmutation Doping (NTD) method using the Japan Materials Testing Reactor (JMTR) has been investigated in Neutron Irradiation and Testing Reactor Center, Japan Atomic Energy Agency (JAEA) in order to expand industry use. As a part of investigations, irradiation test of silicon ingot for development of NTD-Si with high quality was planned using WWR-K in Institute of Nuclear Physics (INP), National Nuclear Center of Republic of Kazakhstan (NNC-RK) based on one of specific topics of cooperation (STC), Irradiation Technology for NTD-Si (STC No.II-4), on the implementing arrangement between NNC-RK and the JAEA for 'Nuclear Technology on Testing/Research Reactors' in cooperation in research and development in nuclear energy and technology. As for the irradiation test, Si rotating device was fabricated in JAEA, and the fabricated device was transported with irradiation specimens from JAEA to INP-NNC-RK. This report described the design, the fabrication, the performance test of the Si rotating device and transportation procedures. (author)

  7. Hyperfine structure investigation of the first excited state 4Isub(13/2) (5,418-1) in Holmium-165 by the atomic beam resonance method

    International Nuclear Information System (INIS)

    Aldenhoven, R.

    1976-01-01

    By the method of atomic beam resonance the hyperfine structure of the first excited state 4 Isub(13/2) (5418 cm -1 ) of 165 Holmium was studied for the first time. Using a suitable ΔF = 0 transition, the gsub(J)-factor was measured. After a determination of estimates for the hyperfine constants A and B from two suitably chosen ΔF = 0 transitions, the hyperfine splittings have been measured. (orig./WL) [de

  8. 33 CFR 166.200 - Shipping safety fairways and anchorage areas, Gulf of Mexico.

    Science.gov (United States)

    2010-07-01

    ... anchorage areas, Gulf of Mexico. 166.200 Section 166.200 Navigation and Navigable Waters COAST GUARD... the erection of structures therein to provide safe approaches through oil fields in the Gulf of Mexico... for Fairway Anchorages in the Gulf of Mexico. Structures may be placed within an area designated as a...

  9. Effect of low doses gamma-irradiation on yield and nitrogen utilization in potato

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Sharanek, A.

    1998-01-01

    Twelve field experiments were conducted in two seasons (1992 and 1993) in three regions of Syria (Damascus, Al-Salamia and Al-Ghab). Tubers of potato (Solanum tuberosum L. var Diamont) were irradiation with gamma-radiation from a 60 Co source, using doses of 0,1,2,3,5 and 10 Gy, at dose rate of 0.15 Gy/min. The irradiated tubers were sown 5-6 days after irradiation, in a randomized complete block design with four replicates and two rates of nitrogen fertilizer (0 and 120 Kg/N/ha). Irradiation and N application significantly increased dry matter production by 24% (for optimal dose) and 38% respectively. The tuber yields were increased by 28.7% for N application and between 13.6 and 19.7 for optimal dose, as a mean for all experiments and regions. Presowing tubers irradiation with 3 Gy. dose also Increased N uptake at harvest by 21.6, 16.6 and 18% for Damascus, Al-Salamia and Al-Ghab respectively. irradiation had negligible effects on N concentration and both Scratch and Vitamin C contents in tubers. (author)

  10. Effects of low doses gamma irradiation on yield and nitrogen utilization in potato

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Sharanik, A.

    1997-12-01

    Twelve field experiments were conducted in two seasons (1992 and 1993) in three regions of Syria (Damascus, Al-Salamia and Al-Ghab). Tubers of potato (Solanum tuberosum L. var Diamont) were irradiated with gamma-radiation from a 60 Co source, using doses of 0,1,2,3,5 and 10 Gy, at dose rate of 0.15 Gy/min. The irradiated tubers were sown 5-6 days after irradiation, in a randomized complete block design with four replicates and two rates of nitrogen fertilizer (0 and 120 Kg/N/ha). Irradiation and N application significantly increased dry matter production by 24% (for optimal dose) and 38% respectively. The tuber yields were increased by 28.7% for N application and between 13.6 and 19.7 for optimal dose, as a mean for all experiments and regions. Presowing tubers irradiation with 3 Gy. dose also Increased N uptake at harvest by 21.6, 16.6 and 18% for Damascus, Al-Salamia and Al-Ghab respectively. irradiation had negligible effects on N concentration and both Scratch and Vitamin C contents in tubers. (author)

  11. Synthesis, characterization, and in vitro evaluation of a radio-metal organic framework composed of in vivo generator {sup 166}Dy/{sup 166}Ho and DOTMP as a novel agent for bone marrow ablation

    Energy Technology Data Exchange (ETDEWEB)

    Vosoghi, Sara; Shirvani-Arani, Simindokht; Bahrami-Samani, Ali; Salek, Nafise; Mirerezaei, Ehsan; Jalilian, Amir Reza [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of)

    2016-07-01

    In this study, the MOF concept contributed to the preparation of a novel, bone-ablating agent composed of Cu(II) using the in vivo generator {sup 166}Dy/{sup 166}Ho and 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetramethylene phosphonic acid (DOTMP). The product was characterized (IR, elemental analysis: CHN, ICM-MS, PIXE, DLS, XRD) and quality-controlled (radio-thin layer chromatography (RTLC)). The stability and in vitro hydroxyapatite binding was checked up to one week at 37 C in human serum. Radio-MOF crystals and colloidal radio-MOF particles were obtained by varying the synthesizing conditions (including pH and temperature), and they had similar IR patterns and similar elemental analysis results. The estimated chemical formula was [1Lu-1Cu-1Cl-1DOTMP] for both. The final product was synthesized at pH = 8 while stirring at room temperature using {sup 166}Dy/{sup 166}Ho-nitrate, CuCl{sub 2}, and DOTMP (yield > 99%, RTLC). Dynamic light scattering (DLS) measurements showed particles in the size range of 60 to 100 nm for the resultant radio-MOF particles (RMP). In vitro binding experiments showed acceptable bone-seeking affinity of the prepared formula even after one week of storage in human serum at 37 C. Importantly, this is the first study of the use of the MOF concept to provide a highly-stable organometallic compound containing {sup 166}Dy/{sup 166}Ho in vivo generator for bone marrow ablation.

  12. NF EN ISO 11137-1, July 2006. Sterilization of health care products - Irradiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    This part of the ISO 11137 standard specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. Although the scope of this part of the ISO 11137 standard is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part of the international standard covers radiation processes employing irradiators using the radionuclide 60 Co or 137 Cs, a beam from an electron generator or a beam from an X-ray generator. This part of the international standard does not: - specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease; - detail specified requirements for designating a medical device as sterile; - specify a quality management system for the control of all stages of production of medical devices; - specify requirements for occupational safety associated with the design and operation of irradiation facilities; - specify requirements for the sterilization of used or reprocessed devices

  13. 3D-FBK Pixel sensors: recent beam tests results with irradiated devices

    CERN Document Server

    Micelli, A; Sandaker, H; Stugu, B; Barbero, M; Hugging, F; Karagounis, M; Kostyukhin, V; Kruger, H; Tsung, J W; Wermes, N; Capua, M; Fazio, S; Mastroberardino, A; Susinno, G; Gallrapp, C; Di Girolamo, B; Dobos, D; La Rosa, A; Pernegger, H; Roe, S; Slavicek, T; Pospisil, S; Jakobs, K; Kohler, M; Parzefall, U; Darbo, G; Gariano, G; Gemme, C; Rovani, A; Ruscino, E; Butter, C; Bates, R; Oshea, V; Parker, S; Cavalli-Sforza, M; Grinstein, S; Korokolov, I; Pradilla, C; Einsweiler, K; Garcia-Sciveres, M; Borri, M; Da Via, C; Freestone, J; Kolya, S; Lai, C H; Nellist, C; Pater, J; Thompson, R; Watts, S J; Hoeferkamp, M; Seidel, S; Bolle, E; Gjersdal, H; Sjobaek, K N; Stapnes, S; Rohne, O; Su, D; Young, C; Hansson, P; Grenier, P; Hasi, J; Kenney, C; Kocian, M; Jackson, P; Silverstein, D; Davetak, H; DeWilde, B; Tsybychev, D; Dalla Betta, G F; Gabos, P; Povoli, M; Cobal, M; Giordani, M P; Selmi, L; Cristofoli, A; Esseni, D; Palestri, P; Fleta, C; Lozano, M; Pellegrini, G; Boscardin, M; Bagolini, A; Piemonte, C; Ronchin, S; Zorzi, N; Hansen, T E; Hansen, T; Kok, A; Lietaer, N; Kalliopuska, J; Oja, A

    2011-01-01

    The Pixel detector is the innermost part of the ATLAS experiment tracking device at the Large Hadron Collider (LHC), and plays a key role in the reconstruction of the primary and secondary vertices of short-lived particles. To cope with the high level of radiation produced during the collider operation, it is planned to add to the present three layers of silicon pixel sensors which constitute the Pixel Detector, an additional layer (Insertable B-Layer, or IBL) of sensors. 3D silicon sensors are one of the technologies which are under study for the IBL. 3D silicon technology is an innovative combination of very-large-scale integration (VLSI) and Micro-Electro-Mechanical-Systems (MEMS) where electrodes are fabricated inside the silicon bulk instead of being implanted on the wafer surfaces. 3D sensors, with electrodes fully or partially penetrating the silicon substrate, are currently fabricated at different processing facilities in Europe and USA. This paper reports on the 2010 June beam test results for irradi...

  14. New therapeutic agent for radiation synovectomy - preparation of {sup 166}Ho-EDTMP-HA particle

    Energy Technology Data Exchange (ETDEWEB)

    Bai, H.; Jin, X.; Du, J.; Wang, F.; Chen, D.; Fan, H.; Cheng, Z.; Zhang, J. [China Institute of Atomic Energy, Beijing (Switzerland). Isotope Department

    1997-10-01

    In order to prepare new therapeutical agent for radiation synovectomy, Hydroxyapatite (HA) was labelled with {sup 166}Ho by EDTMP that had high affinity to HA particles. Radiolabelling of HA particles was divided into two steps, {sup 166}Ho-EDTMP was prepared first; then mixed with HA particles completely and vibrated for 15 minutes on the micromixer at room temperature, washed 3 times with deionized water. Radiolabelling particle was separated from free {sup 166}Ho via centrifugation to determine its radiolabelling efficiency. {sup 166}Ho-EDTMP-HA and {sup 166}Ho-EDTMP were injected into knee joint of normal rabbits respectively, every group was killed at different time postinjection, took out major organ and collected urine and blood, then weighted and determined their radio counts. HA particles, as a natural component of bone was known to have good compatibility with soft tissue and biodegrade into calcium and phosphate in vivo. It was readily prepared from common chemical and formed into particles of desired size range in a controlled process, it had high stability in vitro and vivo. Radiolabelling of HA particle with {sup 166}Ho by EDTMP was simple to perform and provides an excellent labelling yield that was more than 95% under the optimal labelling condition. The optimal labelling condition at room temperature was pH 6.0-8.0 and vibration time 15 minutes. The absorbed capacity of HA particle was 5 mg Ho/g HA particle and size of radiolabelling particle was at range of 2-5,{mu}m that is suitable for therapy of radiation synovectomy. {sup 166}Ho-EDTMP-HA particle demonstrated high in vitro stability in either normal saline or 1% BSA solution, but instability under extremely acidic condition (pH 1-2). The control studies performed with {sup 166}Ho-EDTMP not bound to HA particle provided information on the distribution of radioactivity that would occur upon leakage of the radiochemical compound from joint. Its short half-life, its extremely low leakage from the

  15. Impurity effects in neutron-irradiated simple oxides: Implications for fusion devices

    International Nuclear Information System (INIS)

    Gonzalez, R.; Chen, Y.; Caceres, D.; Vergara, I.

    2006-01-01

    Radiation damage induced by neutron irradiation was studied in undoped MgO crystals and in MgO doped with either iron, hydrogen or lithium impurities. The oxygen-vacancy concentration produced by irradiation increases with neutron fluence. The net production rates resulting from irradiations with 14.8 MeV neutrons are about twice those produced by fission neutrons. In nominally pure crystals, the oxygen-vacancy concentration incurred by the fission-neutron irradiation is higher in crystals with a larger number of inherent impurities (such as iron) due to trapping of interstitials by impurities. Suppression of these defects is observed in MgO:H crystals and attributed to migration of oxygen vacancies to microcavities filled with H 2 gas. In MgO:Li crystals irradiated with neutron fluences below 10 18 n/cm 2 , most of the oxygen vacancies are camouflaged as hydride ions. Nanoindentation experiments show that hardness increases with neutron fluence and is independent of the presence of lithium in the crystal. Comparison between a neutron-irradiated and a thermochemically reduced crystal containing similar concentrations of oxygen vacancies shows that 70% of the neutron-irradiation hardening is produced by interstitials, 30% by oxygen vacancies and a negligible amount by higher-order point defects

  16. Technical cooperation for the wider uses of Ho-166 therapeutic agents in European countries

    CERN Document Server

    Park, K B; Choi, S M; Han, K H; Hong, Y D; Park, W W; Shin, B C

    2002-01-01

    Czech has put their priority in developing the radiopharmaceuticals based on reactor produced Ho-166 and a related fabrication will be extended to other EU conturies including Germany, France, etc after a development of project. The collaboration will be based on the mutual agreement for developing the between research institutes, industries and academic institutes and further researches should be followed by the issue of developing radiopharmaceuticals using Ho-166. To strengthen the collaboration, detailed discussions for the practical collaboration have been made through the visitation to the research institution of each counter part. For implementing the collaboration between NPI and KAERI, an institutional basis technical cooperation agreement(TCA) will be concluded. Furthermore, agreement for the substantial collaboration on Ho-166 related researches will be made after the conclusion of the TCA. It will accelerate the commercialization of KAERI developed Ho-166 therapeutic agents into other European cou...

  17. Hyperfine-interaction-driven suppression of quantum tunneling at zero field in a holmium(III) single-ion magnet

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yan-Cong; Liu, Jun-Liang; Chen, Xiao-Ming; Tong, Ming-Liang [Key Lab. of Bioinorganic and Synthetic Chemistry of Ministry of Education, School of Chemistry, Sun Yat-Sen Univ., Guangzhou (China); Wernsdorfer, Wolfgang [Institut Neel, CNRS and Universite Joseph Fournier, Grenoble (France); Institute of Nanotechnology, Karlsruhe Institute of Technology (Germany); Physikalisches Institut, Karlsruhe Institute of Technology (Germany); Liu, Dan; Chibotaru, Liviu F. [Theory of Nanomaterials Group and INPAC-Institute of Nanoscale Physics and Chemistry, Katholieke Universiteit Leuven (Belgium)

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm{sup -1}. The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from {sup 165}Ho (I=7/2) with a natural abundance of 100 %. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Beta dosimetry in intraperitoneal administration of 166Ho-chitosan complex

    International Nuclear Information System (INIS)

    Kim, E. H.; Lim, S. M.; Park, K. B.

    1998-01-01

    Intraperitoneal administration of radioisotopes is suggested to treat the metastatic ovarian cancer in the peritoneal cavity. Administering beta-emitting radioisotopes into the peritoneal cavity allows the maximum energy delivery to the cancerous cells of the peritoneal wall surface while sparing the normal cells located in deep site of the peritoneal wall. In this study, dose estimates of the peritoneal wall are provided to be used for prescribing the amount of 166 Ho-chitosan complex administered. The 166 Ho-chitosan complex diffused in the peritoneal fluid may attach to the peritoneal wall surface. The attachment fraction of 166 Ho-chitosan complex to the peritoneal wall surface is obtained by simulating the ascites with Fischer rats. Both volume source in the peritoneal fluid and the surface source over the peritoneal wall surface are counted for the contribution to the peritoneal wall dose. The Monte Carlo code EGS4 is used to simulate the energy transfer of the beta particles emitted from 166 Ho. A plane geometrical model of semi-infinite volume describes the peritoneal cavity and the peritoneal wall. A semi-infinite plane of 10 μm in thickness at every 1 mm of depth in the peritoneal wall is taken as the target in dose estimation. Greater than 98 percents of attachment fraction has been observed from the experiments with Fischer rats. Given 1.3 μCi/cm 2 and 2.4 μCi/ml of uniform activity density, absorbed dose is 123 Gy, 8.59 Gy, 3.00 Gy, 1.03 Gy, and 327 Gy at 0 mm, 1 mm, 2 mm, 3 mm, and 4 mm in depth to the peritoneal wall, respectively

  19. Investigation of the effect of some irradiation parameters on the response of various types of dosimeters to electron irradiation

    International Nuclear Information System (INIS)

    Farah, K.; Kuntz, F.; Kadri, O.; Ghedira, L.

    2004-01-01

    Several undyed and dyed polymer films are commercially available for dosimetry in intense radiation fields, especially for radiation processing of food and sterilisation of medical devices. The effects of temperature during irradiation and post-irradiation stability, on the response of these dosimeters are of importance to operators of irradiation facilities. The present study investigates the effects of temperature during irradiation by 2.2 MeV electrons beam accelerator and post irradiation storage on the response of several types of dosimeter films. All dosimeters showed a significant effect of temperature during irradiation and post-irradiation storage

  20. Investigation of the effect of some irradiation parameters on the response of various types of dosimeters to electron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Farah, K. E-mail: k.farah@cnstn.rnrt.tn; Kuntz, F.; Kadri, O.; Ghedira, L

    2004-10-01

    Several undyed and dyed polymer films are commercially available for dosimetry in intense radiation fields, especially for radiation processing of food and sterilisation of medical devices. The effects of temperature during irradiation and post-irradiation stability, on the response of these dosimeters are of importance to operators of irradiation facilities. The present study investigates the effects of temperature during irradiation by 2.2 MeV electrons beam accelerator and post irradiation storage on the response of several types of dosimeter films. All dosimeters showed a significant effect of temperature during irradiation and post-irradiation storage.

  1. 7 CFR 400.166 - Obligations of the Corporation.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Obligations of the Corporation. 400.166 Section 400... CORPORATION, DEPARTMENT OF AGRICULTURE GENERAL ADMINISTRATIVE REGULATIONS Reinsurance Agreement-Standards for... Corporation. The Agreement will include the following among the obligations of the Corporation. (a) The...

  2. Extended study on oxidation behaviors of UN0.68 and UN1.66 by XPS

    Science.gov (United States)

    Luo, Lizhu; Hu, Yin; Pan, Qifa; Long, Zhong; Lu, Lei; Liu, Kezhao; Wang, Xiaolin

    2018-04-01

    The surface oxidation behaviors of UN0.68 and UN1.66 thin films are investigated by X-ray photoelectron spectroscopy (XPS), and the traditional U4f/N1s, O1s, valence band spectra as well as the unconventional U4d and U5d spectra are collected for the understanding of their oxidation behavior in-depth. Similar asymmetrical peak shape of the U4f spectra to uranium is observed for both uranium nitrides, despite of a slight shift to higher energy side for UN1.66 clean surface. However, significant difference among the corresponding spectra of UN0.68 and UN1.66 during oxidation reveals the distinctive properties of each own. The coexistence of UO2-x, UO2 and UO2-x.Ny on UN0.68 surface results in the peculiar features of U4f spectra as well as the others within the XPS energy scale, where peaks of the oxidized species firstly shift to higher energy side compared to the clean surface, and then return closely towards those of stoichiometric UO2. For UN1.66, the generation of U-N-O ternary compounds on the surface is identified with the symmetrical U4f peaks at 379.9eV and 390.8 eV, which locate intermediate between UO2 and UN1.66, and gradually expanding to higher energy side during the progressive oxidation. Furthermore, the formation of N-O species on UN1.66 surface is also detected as an oxidation product. The metallic character of UN1.66 is identified by the intense signal at Fermi level, which is greatly suppressed by the increasing oxygen exposure and implies the weakening metallic properties of the as-generated U-N-O compounds. Higher uranium oxides, such as UO3 and U4O9, are deduced to be the final oxidation products, and a multistage mechanism for UN1.66 following the exposure to oxygen is discussed.

  3. Measurement of thermal neutron cross-section and resonance integral for the 165Ho(n,γ) 166gHo reaction using electron linac-based neutron source

    Science.gov (United States)

    Nguyen, Van Do; Pham, Duc Khue; Kim, Tien Thanh; Kim, Guinyun; Lee, Manwoo; Kim, Kyung Sook; Kang, Heung-Sik; Cho, Moo-Hyun; Ko, In Soo; Namkung, Won

    2011-01-01

    The thermal neutron cross-section and the resonance integral of the 165Ho(n,γ) 166gHo reaction have been measured by the activation method using a 197Au(n,γ) 198Au monitor reaction as a single comparator. The high-purity natural Ho and Au foils with and without a cadmium shield case of 0.5 mm thickness were irradiated in a neutron field of the Pohang neutron facility. The induced activities in the activated foils were measured with a calibrated p-type high-purity Ge detector. The correction factors for the γ-ray attenuation ( Fg), the thermal neutron self-shielding ( Gth), the resonance neutron self-shielding ( Gepi) effects, and the epithermal neutron spectrum shape factor ( α) were taken into account. The thermal neutron cross-section for the 165Ho(n,γ) 166gHo reaction has been determined to be 59.7 ± 2.5 barn, relative to the reference value of 98.65 ± 0.09 barn for the 197Au(n,γ) 198Au reaction. By assuming the cadmium cut-off energy of 0.55 eV, the resonance integral for the 165Ho(n,γ) 166gHo reaction is 671 ± 47 barn, which is determined relative to the reference value of 1550 ± 28 barn for the 197Au(n,γ) 198Au reaction. The present results are, in general, good agreement with most of the previously reported data within uncertainty limits.

  4. Development of irradiation support devices for production of brachytherapy seeds

    Energy Technology Data Exchange (ETDEWEB)

    Mattos, Fabio R.; Rostelato, Maria Elisa C.M.; Zeituni, Carlos A.; Souza, Carla D.; Moura, Joao A.; Peleias Junior, Fernando S.; Karan Junior, Dib; Feher, Anselmo; Oliveira, Tiago B.; Benega, Marcos A.G., E-mail: tiagooliveira298@gmail.com, E-mail: mattos.fr@gmail.com, E-mail: elisaros@ipen.br, E-mail: czeituni@ipen.br, E-mail: carladdsouza@yahoo.com.br, E-mail: jamoura@ipen.br, E-mail: ernandopeleias@gmail.com, E-mail: s, E-mail: dib.karan@usp.br, E-mail: afeher@ipen.br, E-mail: marcosagbenega@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Ophthalmic tumors treatment with brachytherapy sources has been widely used as a primary or secondary therapy for non-malignant or malignant tumors, for example, choroid melanoma, and retinoblastoma. Ruthenium-106, Iodine-125, Palladium -103, Gold-198 and Iridium-192, are some radionuclides that can be applied for treatment of ocular tumors. These sources are in small sizes (a few millimeters) and different shapes (rods, wires, disks). To ensure high accuracy during treatment, they are positioned in eye applicators, specially designed to fit on the surface of tumor. The Nuclear and Energy Research Institute (IPEN/CNEN) in a partnership with Paulista Medicine School (UNIFESP) created a project that aims to develop a prototype of Iridium-192 seeds for treatment of eye cancer. This seed consists in a core of Ir -Pt alloy (20%-80%) with a length of 3 mm, to be activated in IPEN's IEA-R1 Reactor, and a titanium capsule sealing the core. It was imperative to develop a sustainer device for irradiation. This piece is used to avoid overlapping of one cores and, therefore, avoiding the 'shadow effect' that does not allow full activation of each core due to the high density. (author)

  5. Tissue irradiator

    International Nuclear Information System (INIS)

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1975-01-01

    A tissue irradiator is provided for the in-vivo irradiation of body tissue. The irradiator comprises a radiation source material contained and completely encapsulated within vitreous carbon. An embodiment for use as an in-vivo blood irradiator comprises a cylindrical body having an axial bore therethrough. A radioisotope is contained within a first portion of vitreous carbon cylindrically surrounding the axial bore, and a containment portion of vitreous carbon surrounds the radioisotope containing portion, the two portions of vitreous carbon being integrally formed as a single unit. Connecting means are provided at each end of the cylindrical body to permit connections to blood-carrying vessels and to provide for passage of blood through the bore. In a preferred embodiment, the radioisotope is thulium-170 which is present in the irradiator in the form of thulium oxide. A method of producing the preferred blood irradiator is also provided, whereby nonradioactive thulium-169 is dispersed within a polyfurfuryl alcohol resin which is carbonized and fired to form the integral vitreous carbon body and the device is activated by neutron bombardment of the thulium-169 to produce the beta-emitting thulium-170

  6. Design, construction, and in vivo feasibility of a positioning device for irradiation of mice brains using a clinical linear accelerator and intensity modulated radiation therapy.

    Science.gov (United States)

    Rancilio, Nicholas J; Dahl, Shaun; Athanasiadi, Ilektra; Perez-Torres, Carlos J

    2017-12-01

    The goal of this study was to design a positioning device that would allow for selective irradiation of the mouse brain with a clinical linear accelerator. We designed and fabricated an immobilization fixture that incorporates three functions: head stabilizer (through ear bars and tooth bar), gaseous anesthesia delivery and scavenging, and tissue mimic/bolus. Cohorts of five mice were irradiated such that each mouse in the cohort received a unique dose between 1000 and 3000 cGy. DNA damage immunohistochemistry was used to validate an increase in biological effect as a function of radiation dose. Mice were then followed with hematoxylin and eosin (H&E) and anatomical magnetic resonance imaging (MRI). There was evidence of DNA damage throughout the brain proportional to radiation dose. Radiation-induced damage at the prescribed doses, as depicted by H&E, appeared to be constrained to the white matter consistent with radiological observation in human patients. The severity of the damage correlated with the radiation dose as expected. We have designed and manufactured a device that allows us to selectively irradiate the mouse brain with a clinical linear accelerator. However, some off-target effects are possible with large prescription doses.

  7. Irradiation of goods

    International Nuclear Information System (INIS)

    Lunt, R.E.

    1987-01-01

    Mechanical handling apparatus is adapted to handle goods, such as boxed fruit, during a process of irradiation, in palletized form. Palletized goods are loaded onto wheeled vehicles in a loading zone. Four vehicles are wheeled on a track into an irradiation zone via a door in a concrete shield. The vehicles are arranged in orthogonal relationship around a source of square section. Turntables are positioned at corners of the square shaped rail truck around the source selectively to turn the vehicles to align then with track sections. Mechanical manipulating devices are positioned in the track sections opposed to sides of the source. During irradiation, the vehicles and their palletized goods are cylically moved toward the source to offer first sides of the goods for irradiation and are retraced from the source and are pivoted through 90 0 to persent succeeding sides of the goods for irradiation

  8. Evaluation of set-of errors in pelvic irradiation with electronic portal imaging device

    International Nuclear Information System (INIS)

    Wu Xiaoying; Zhang Zhen; Wang Wenchao; Ren Jun; Guo Xiaomei; Lu Huizhong

    2007-01-01

    Objective: Evaluate the systematic and random set-up error in the pelvic irradiation u- sing electronic portal imaging device(EPID) to provide institution-specific margin for PTV design in pelvic cancer treatment planning with 3D conformal therapy and/or IMRT. Methods: From May to August 2005, twelve patients who received pelvic irradiation, were involved in this study. CT simulations were performed and DRRs were generated as the reference images. Ant-post and lateral portal images were taken daily, and total of 244 sets of EPID images were collected for the whole group. The translational shifts along right-left, superior-inferior and anterior-posterior directions were calculated with aligning the pelvic bony structures on the DRRs and electronic portal images. The systematic and random setup errors were evaluated based on the 244 sets of data. PTV margin was assessed assuming target rotation was negligible. Results: In the right- left (R-L), superior-inferior (S-I) and anterior-posterior (A-P) directions, the maximum shifts were 9.9, 14.0 and 21.1 mm and the systematic setup errors were 0.5, 0.2 and 2.3 mm respectively. For all 244 sets of data in this study, the frequency of the shift larger than 10 mm were 0% (R-L), 1% (S-I) and 3% (A -P); and in R-L and S-I direction, 92% and 91% of the times the shift was smaller than 5 mm. However, only 79% of the times the A-P shift was less than 5 mm. Conclusions: It is suggested in this study that in order to achieve a target coverage of better than 95% of the times throughout the pelvic irradiation in our institution, a 5 mm PTV margin in right-left and superior-inferior directions is required, however, the anterior-posterior margin needs to be increased to at least 10 mm. One needs to be cautious though when applying the PTV margin derived from small sample of patient population to individual patient. (authors)

  9. Brain fibronectin expression in prenatally irradiated mice

    International Nuclear Information System (INIS)

    Meznarich, H.K.; McCoy, L.S.; Bale, T.L.; Stiegler, G.L.; Sikov, M.R.

    1993-01-01

    Activation of gene transcription by radiation has been recently demonstrated in vivo. However, little is known on the specificity of these alterations on gene transcription. Prenatal irradiation is a known teratogen that affects the developing mammalian central nervous system (CNS). Altered neuronal migration has been suggested as a mechanism for abnormal development of prenatally irradiated brains. Fibronectin (FN), an extracellular glycoprotein, is essential for neural crest cell migration and neural cell growth. In addition, elevated levels of FN have been found in the extracellular matrix of irradiated lung. To test whether brain FN is affected by radiation, either FN level in insoluble matrix fraction or expression of FN mRNA was examined pre- and postnatally after irradiation. Mice (CD1), at 13 d of gestation (DG), served either as controls or were irradiated with 14 DG, 17 DG, or 5,6, or 14 d postnatal. Brain and liver were collected from offspring and analyzed for either total FN protein levels or relative mRNAs for FN and tubulin. Results of prenatal irradiation on reduction of postnatal brain weight relative to whole are comparable to that reported by others. Insoluble matrix fraction (IMF) per gram of brain, liver, lung, and heart weight was not significantly different either between control and irradiated groups or between postnatal stages, suggesting that radiation did not affect the IMF. However, total amounts of FN in brain IMF at 17 DG were significantly different (p < .02) between normal (1.66 ± 0.80 μg) and irradiated brains (0.58 ± 0.22 μg). FN mRNA was detectable at 13, 14, and 17 DG, but was not detectable at 6 and 14 d postnatal, indicating that FN mRNA is developmentally regulated. 41 refs., 4 figs., 3 tabs

  10. Effects of gamma irradiation on the shoot length of Cicer seeds

    International Nuclear Information System (INIS)

    Toker, Cengiz; Uzun, Bulent; Canci, Huseyin; Oncu Ceylan, F.

    2005-01-01

    The effects of radiation on the shoot and root lengths of germinated seedling of irradiated seeds of Cicer species, i.e. three kabuli types and four desi types of cultivated chickpea (Cicer arietinum Ladiz.) and 2 annual wild types (C. reticulatum Ladiz. and C. bijugum K.H. Rech.) were investigated. The seeds were irradiated with a 60 Co gamma source using 0, 200, 300 and 400 Gy doses at 1.66 kGy h -1 . At 200 Gy minor effects could be observed, but at 400 Gy an obvious depression of shoot length was observed. The kabuli types were more affected than the desi ones. The critical dose that prevented the shoot and root elongation varied among species and also ranged from genotypes to genotype within species

  11. Nuclear level density of 166Er with static deformation

    International Nuclear Information System (INIS)

    Nasrabadi, M.N.

    2006-01-01

    The level densities of 166 Er is calculated using the microscopic theory of interacting fermions and is compared with experimental. It is concluded that the data can be reproduced with level density formalism for nuclei with static deformation

  12. Minimizing material damage using low temperature irradiation

    Science.gov (United States)

    Craven, E.; Hasanain, F.; Winters, M.

    2012-08-01

    Scientific advancements in healthcare driven both by technological breakthroughs and an aging and increasingly obese population have lead to a changing medical device market. Complex products and devices are being developed to meet the demands of leading edge medical procedures. Specialized materials in these medical devices, including pharmaceuticals and biologics as well as exotic polymers present a challenge for radiation sterilization as many of these components cannot withstand conventional irradiation methods. The irradiation of materials at dry ice temperatures has emerged as a technique that can be used to decrease the radiation sensitivity of materials. The purpose of this study is to examine the effect of low temperature irradiation on a variety of polymer materials, and over a range of temperatures from 0 °C down to -80 °C. The effectiveness of microbial kill is also investigated under each of these conditions. The results of the study show that the effect of low temperature irradiation is material dependent and can alter the balance between crosslinking and chain scission of the polymer. Low temperatures also increase the dose required to achieve an equivalent microbiological kill, therefore dose setting exercises must be performed under the environmental conditions of use.

  13. Analysis of interfraction and intrafraction variation during tangential breast irradiation with an electronic portal imaging device

    International Nuclear Information System (INIS)

    Smith, Ryan P.; Bloch, Peter; Harris, Eleanor E.; McDonough, James; Sarkar, Abhirup; Kassaee, Alireza; Avery, Steven; Solin, Lawrence J.

    2005-01-01

    Purpose: To evaluate the daily setup variation and the anatomic movement of the heart and lungs during breast irradiation with tangential photon beams, as measured with an electronic portal imaging device. Methods and materials: Analysis of 1,709 portal images determined changes in the radiation field during a treatment course in 8 patients. Values obtained for every image included central lung distance (CLD) and area of lung and heart within the irradiated field. The data from these measurements were used to evaluate variation from setup between treatment days and motion due to respiration and/or patient movement during treatment delivery. Results: The effect of respiratory motion and movement during treatment was minimal: the maximum range in CLD for any patient on any day was 0.25 cm. The variation caused by day-to-day setup variation was greater, with CLD values for patients ranging from 0.59 cm to 2.94 cm. Similar findings were found for heart and lung areas. Conclusions: There is very little change in CLD and corresponding lung and heart area during individual radiation treatment fractions in breast tangential fields, compared with a relatively greater amount of variation that occurs between days

  14. Gemstone enhancing dedicated gamma irradiator development; Desenvolvimento de irradiador gama dedicado ao beneficiamento de pedras preciosas

    Energy Technology Data Exchange (ETDEWEB)

    Omi, Nelson Minoru

    2006-07-01

    The gemstones gamma irradiation process to enhance the color is widely accepted for the jewelry industry. These gems are processed in conventional industrial gamma irradiation plant which are optimized for other purposes, using underwater irradiation devices with high rejection rate due to it's poor dose uniformity. A new conception design, which states the working principles and manufacturing ways of the device, was developed in this work. The suggested device's design is based on the rotation of cylindrical baskets and their translation in circular paths inside and outside a cylindrical source rack as a planetary system. The device is meant to perform the irradiation in the bottom of the source storage pool, where the sources remain always shielded by the water layer. The irradiator matches the Category III IAEA classification. To verify the physical viability of the basic principle, tests with rotating cylindrical baskets were performed in the Multipurpose Irradiator raised in the CTR, IPEN. Also, simulations using the CADGAMMA software, adapted to simulate underwater irradiations were performed. With the definitive irradiator, the irradiation quality will be enhanced with better dose control and the production costs will be significantly lower than market prices due to the intended treatment device's optimization. (author)

  15. 25 CFR 166.223 - Can I use a permit as collateral for a loan?

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Can I use a permit as collateral for a loan? 166.223... PERMITS Permit Requirements Permit (leasehold) Mortgage § 166.223 Can I use a permit as collateral for a loan? We may approve a permit containing a provision that authorizes the permittee to encumber the...

  16. Present status of radiation application on irradiation service

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi

    2006-01-01

    Presently, it is in operation 6 gamma-ray facilities and 5 electron beam (EB) facilities for an irradiation service. New gamma-ray facility is under construction, and will be worked in August this year. These facilities are generally employed for crosslinking and decomposition of polymers, graft polymerization, improvement of semiconductor properties, sterilization of medical devices, laboratory-animals feed, packing materials and biotechnological devices. As for being feature one of EB facilities is employed only for improvement of polymers and semiconductors. Approximately 91% of gamma-ray sterilization of medical devices is processed in house, and 5 facilities are working in 4 firms. Other two firms have 4 EB facilities for sterilization. Therefore, the degree of dependence of irradiation service is low in the sterilization of medical devices. About 50% of medical devices are still sterilized by ethylene oxide gas (EOG). However, a part of laws has been amended successively from 5 years ago, and the regulation of EOG handling became harsh. Therefore, EOG sterilization will be gradually displaced in radiation sterilization. On the other hand, demand for sterilization of the packing materials has increased significantly, and various kinds of packing materials in food industry are sterilized by both gamma-rays and EB. Currently, novel PMMA dosimeter was developed and named Radix W. The dosimeter allows measurement of doses from 1 kGy to 150 kGy without influence of dose rates and irradiation temperature. The activities of irradiation service probably will continue to increase over future. (author)

  17. 26 CFR 1.166-2 - Evidence of worthlessness.

    Science.gov (United States)

    2010-04-01

    ... accounting.” The words “ELECTION UNDER § 1.166-2(d)(3)” must be typed or legibly printed at the top of the... connection with its most recent examination involving the bank's loan review process, the bank's supervisory... procedure prescribed hereunder) that the bank maintains and applies loan loss classification standards that...

  18. Structural and functional characterization of human apolipoprotein E 72-166 peptides in both aqueous and lipid environments

    Directory of Open Access Journals (Sweden)

    Chou Chi-Yuan

    2011-01-01

    Full Text Available Abstract Backgrounds There are three apolipoprotein E (apoE isoforms involved in human lipid homeostasis. In the present study, truncated apoE2-, apoE3- and apoE4-(72-166 peptides that are tailored to lack domain interactions are expressed and elucidated the structural and functional consequences. Methods & Results Circular dichroism analyses indicated that their secondary structure is still well organized. Analytical ultracentrifugation analyses demonstrated that apoE-(72-166 produces more complicated species in PBS. All three isoforms were significantly dissociated in the presence of dihexanoylphosphatidylcholine. Dimyristoylphosphatidylcholine turbidity clearance assay showed that apoE4-(72-166 maintains the highest lipid-binding capacity. Finally, only apoE4-(72-166 still maintained significant LDL receptor binding ability. Conclusions Overall, apoE4-(72-166 peptides displayed a higher lipid-binding and comparable receptor-binding ability as to full-length apoE. These findings provide the explanation of diverged functionality of truncated apoE isoforms.

  19. Minimizing material damage using low temperature irradiation

    International Nuclear Information System (INIS)

    Craven, E.; Hasanain, F.; Winters, M.

    2012-01-01

    Scientific advancements in healthcare driven both by technological breakthroughs and an aging and increasingly obese population have lead to a changing medical device market. Complex products and devices are being developed to meet the demands of leading edge medical procedures. Specialized materials in these medical devices, including pharmaceuticals and biologics as well as exotic polymers present a challenge for radiation sterilization as many of these components cannot withstand conventional irradiation methods. The irradiation of materials at dry ice temperatures has emerged as a technique that can be used to decrease the radiation sensitivity of materials. The purpose of this study is to examine the effect of low temperature irradiation on a variety of polymer materials, and over a range of temperatures from 0 °C down to −80 °C. The effectiveness of microbial kill is also investigated under each of these conditions. The results of the study show that the effect of low temperature irradiation is material dependent and can alter the balance between crosslinking and chain scission of the polymer. Low temperatures also increase the dose required to achieve an equivalent microbiological kill, therefore dose setting exercises must be performed under the environmental conditions of use. - Highlights: ► A study is performed to quantify low temperature irradiation effects on polymer materials and BIs. ► Low temperature irradiation alters the balance of cross-linking and chain scissoning in polymers. ► Low temperatures provide radioprotection for BIs. ► Benefits of low temperatures are application specific and must be considered when dose setting.

  20. Chalcogenide glasses for device application modified by high-energy irradiation

    International Nuclear Information System (INIS)

    Kavetskyy, T.; Shpotyuk, O.

    2006-01-01

    Full text: Chalcogenide glasses (ChG) or chemical compounds of chalcogen atoms (S, Se or Te, but not O) with some elements from IV-th and V-th groups of the Periodic Table (typically As, Ge, Sb, Bi, etc. ) obtained by melt quenching, are a perspective for application in modern optoelectronics, photonics, telecommunications, acoustic-optics, xerography, lithography, etc. This uniqueness is due to extremely high sensitivity of ChG to external influences, associated, presumably, with high steric flexibility proper to glassy-like network with low average atomic coordination (chalcogen atoms are typically two-fold coordinated in a glassy-like network), relatively large internal free volume and specific lp-character of electronic states localized at a valence-band top. However, at present, the further possibilities for conventional chemical/technological methods to prepare ChG are fully exhausted. One of the steps to resolve this problem is post-technological modification of ChG using possibilities of high-energy irradiation. This work is focused on new advanced radiation-modified ChG for device application in optoelectronics. The attractive practical use of these non-crystalline materials is tightly connected with radiation-induced defect formation processes. For the first time, we consider the possibilities of Raman scattering along with X-ray diffraction and positron annihilation lifetime spectroscopy to characterize microstructural mechanisms of radiation-induced effects in ChG. (authors)

  1. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  2. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  3. Influence of burn-in on total-ionizing-dose effect of SRAM device

    International Nuclear Information System (INIS)

    Liu Minbo; Yao Zhibin; Huang Shaoyan; He Baoping; Sheng Jiangkun

    2014-01-01

    The influence of Burn-in on the total-ionizing-dose (TID) effect of SRAM device was investigated. SRAM devices of three different feature sizes were selected and irradiated by "6"0Co source with or without pre-irradiation Burn-in. Some parameters for radiation effect of SRAM device such as upset data, were measured, and the influence on the TID effect of different feature size SRAM devices with or without pre-irradiation Burn-in was obtained. The influence of different temperature Burn-in on radiation resistant capability of SRAM device was studied for 0.25 μm SRAM device. The results show that the smaller the device feature size is, the better the radiation-resistant capability of SRAM device is and the weaker the influence of Burn-in is. And the higher Burn-in temperature is, the more serious the influence of Burn-in on the total-dose radiation effect is. (authors)

  4. Details management in the application of percutaneous nephroscope holmium laser lithotripsy%细节管理在经皮肾镜钬激光碎石术中的应用研究

    Institute of Scientific and Technical Information of China (English)

    王地萍; 张红芹

    2014-01-01

    目的:观察细节管理在经皮肾镜钬激光碎石术中的应用效果。方法:通过对56例患者进行经皮肾镜钬激光碎石的手术配合和对其围手术期的护理,总结出手术各个环节的护理要点。结果:56例手术患者中,一例中转切开取石,其余55例均碎石成功,效果非常满意,无并发症发生。结论:经皮肾镜钬激光碎石术具有出血少,创伤小,痛苦少,住院时间短、病人恢复快等优点,做好护理细节管理是保证手术顺利完成的重要条件。%Objective:To observe the details of the management in the application of percutaneous nephroscope holmium laser lithotripsy. Methods:By means of 56 patients with percutaneous nephroscope holmium laser lithotrip-sy procedure and the perioperative nursing, sums up the operation nursing key points of each part. Results:56 pa-tients with surgery, in case of transit the stones cut, the remaining 55 cases of gravel, effect is very satisfactory, no complications occurred. Conclusion: Percutaneous nephroscope holmium laser lithotripsy with less bleeding, small trauma, less pain, shorter hospitalization time and patients recover fast, do a good job in nursing detail management is vital to ensure that operation is completed.

  5. Extracorporeal irradiation of dog blood: the effects of a radiostrontium irradiator on blood stem cells (CFU-C)

    Energy Technology Data Exchange (ETDEWEB)

    Szemere, P.; Fliedner, T.M.; Nothdurft, W.; Breitig, D.

    1982-07-01

    The radiation sensitivity of dog blood stem cells was measured in vitro and in an extracorporeal circulation passing through a radiation field. It was established that the calculated D/sub 0/ was as low as 0.45 Gy. Investigating the cell killing rate in our equipment (Buchler type /sup 90/Sr device for extracorporeal irradiation), we found an overkill situation; the dose delivered was in excess of that which would be required for the total eradication of all stem cells in the peripheral blood passing through the radiation field. Various other types of devices used for extracorporeal irradiation of blood are also reviewed.

  6. 40 CFR 166.24 - Public notice of receipt of application and opportunity for public comment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Public notice of receipt of application and opportunity for public comment. 166.24 Section 166.24 Protection of Environment ENVIRONMENTAL... of the applicant's description of the emergency conditions including the pest and the site or crop to...

  7. Creation of a plant for gamma-sterilization of the medical equipment and irradiation of industrial materials

    International Nuclear Information System (INIS)

    Maltceva, F.; Petukhov, V.; Chekushin, A.

    1996-01-01

    The purpose of the project. To create a powerful irradiation devices allowing to fulfill the irradiation of large-sized objects with dozes up to 4 Rad, and caring out the irradiation technologies by using of it. The basic tasks of the project and sequence of fulfillment. The realization of irradiating technologies is possible at WWR-K research reactor that is located near of Almaty . At the reactor complex, there are the means for creation powerful irradiating devices, and quite qualified personnel having the experience of works with radioactive materials is available. All of it allows, both for the staff and for the population living nearby, to have the radiation safety during of caring out of the work with the use of high intensive radioactive sources. Technical problems. The creation of plant has the following stages: - fulfilling of the calculation and design work; - caring out of mechanical works on manufacturing the irradiating devices, cartridges for irradiating sources and a hermetic tank for irradiated objects; - installation of devices, fulfilling of the tests; - purchasing or manufacturing of radioactive sources (-10-60); - loading of the sources into devices, and realization of measurements of the fields of gamma field inside the container; - making up the working instruction; - training of the personnel

  8. Actin re-organization induced by Chlamydia trachomatis serovar D--evidence for a critical role of the effector protein CT166 targeting Rac.

    Directory of Open Access Journals (Sweden)

    Jessica Thalmann

    Full Text Available The intracellular bacterium Chlamydia trachomatis causes infections of urogenital tract, eyes or lungs. Alignment reveals homology of CT166, a putative effector protein of urogenital C. trachomatis serovars, with the N-terminal glucosyltransferase domain of clostridial glucosylating toxins (CGTs. CGTs contain an essential DXD-motif and mono-glucosylate GTP-binding proteins of the Rho/Ras families, the master regulators of the actin cytoskeleton. CT166 is preformed in elementary bodies of C. trachomatis D and is detected in the host-cell shortly after infection. Infection with high MOI of C. trachomatis serovar D containing the CT166 ORF induces actin re-organization resulting in cell rounding and a decreased cell diameter. A comparable phenotype was observed in HeLa cells treated with the Rho-GTPase-glucosylating Toxin B from Clostridium difficile (TcdB or HeLa cells ectopically expressing CT166. CT166 with a mutated DXD-motif (CT166-mut exhibited almost unchanged actin dynamics, suggesting that CT166-induced actin re-organization depends on the glucosyltransferase motif of CT166. The cytotoxic necrotizing factor 1 (CNF1 from E. coli deamidates and thereby activates Rho-GTPases and transiently protects them against TcdB-induced glucosylation. CNF1-treated cells were found to be protected from TcdB- and CT166-induced actin re-organization. CNF1 treatment as well as ectopic expression of non-glucosylable Rac1-G12V, but not RhoA-G14A, reverted CT166-induced actin re-organization, suggesting that CT166-induced actin re-organization depends on the glucosylation of Rac1. In accordance, over-expression of CT166-mut diminished TcdB induced cell rounding, suggesting shared substrates. Cell rounding induced by high MOI infection with C. trachomatis D was reduced in cells expressing CT166-mut or Rac1-G12V, and in CNF1 treated cells. These observations indicate that the cytopathic effect of C. trachomatis D is mediated by CT166 induced Rac1 glucosylation

  9. Sampling by electro-erosion on irradiated materials

    International Nuclear Information System (INIS)

    Riviere, M.; Pizzanelli, J.P.

    1986-05-01

    Sampling on irradiated materials, in particular for mechanical property study of steels in the FAST NEUTRON program needed the set in a hot cell of a machining device by electroerosion. This device allows sampling of tenacity, traction, resilience test pieces [fr

  10. Neutronic, thermal-hydraulics and safety calculations of a Miniplate Irradiation Device (MID) of dispersion type fuel elements; Calculos neutronicos, termo-hidraulicos e de seguranca de um dispositivo para Irradiacao de miniplacas (DIM) de elementos combustiveis tipo dispersao

    Energy Technology Data Exchange (ETDEWEB)

    Domingos, Douglas Borges

    2010-07-01

    Neutronic, thermal-hydraulics and accident analysis calculations were developed to estimate the safety of a Miniplate Irradiation Device (MID) to be placed in the IEA-R1 reactor core. The irradiation device is used to receive miniplates of U{sub 3}O{sub 8}-Al and U{sub 3}Si{sub 2}- Al dispersion fuels, LEU type (19.75 % {sup 235}U) with uranium densities of, respectively, 3.2 gU/cm{sup 3} and 4.8 gU/cm{sup 3}. The fuel miniplates will be irradiated to nominal {sup 235}U burnup levels of 50% and 80%, in order to qualify the above high-density dispersion fuels to be used in the Brazilian Multipurpose Reactor (RMB), now in the conception phase. For the neutronic calculation, the computer codes CITATION and 2DB were utilized. The computer code FLOW was used to calculate the coolant flow rate in the irradiation device, allowing the determination of the fuel miniplate temperatures with the computer model MTRCR-IEA-R1. A postulated Loss of Coolant Accident (LOCA) was analyzed with the computer codes LOSS and TEMPLOCA, allowing the calculation of the fuel miniplate temperatures after the reactor pool draining. The calculations showed that the irradiation should occur without adverse consequences in the IEA-R1 reactor. (author)

  11. The environmental impact of irradiation plants

    International Nuclear Information System (INIS)

    Bennett, N; Langley, R; Reuter, G

    1998-01-01

    The radiation sterilization of disposable medical devices and other medical products brings major benefits to mankind. Furthermore there are potential opportunities to use the irradiation process to significantly improve our environment. Careful examination of the environmental impact of both electron beam and gamma irradiators confirms that these major benefits are not achieved at any significant environmental cost

  12. Fuel pins irradiation: experimental devices and analytical behaviour

    International Nuclear Information System (INIS)

    Lemaignan, C.

    1996-01-01

    In this text we present the general characteristics of adapted irradiation loops in research reactors and the main results that we can expected with these loops in the behaviour field of PWR and LMFBR fuels( fuel densification, fuel cladding interactions, fission products release, reactor accidents)

  13. In-pile gamma spectrometry and irradiation control at Osiris

    International Nuclear Information System (INIS)

    Farny, G.; Destot, M.; Corre, J.; Texier, D.; Faugere, J.L.; Mouchnino, M.

    1975-01-01

    A new gamma spectrometry facility is available near Osiris reactor core, at Saclay. This device enables nuclear fuels to be examined in loops or capsules all along their irradiation, a few minutes being sufficient to transfer the fuel from the irradiation place to the measurement bench. So, spacelike and timelike history of a lot of fission products, especially short-lived radionuclides, can be observed. Using such in-pile spectrometry device, of original design, allows to avoid radioactive decay corrections and the risks of any information less. Performance of the device is given together with some preliminary results and their interpretation [fr

  14. Isomer decay spectroscopy of 164Sm and 166Gd: midshell collectivity around N=100.

    Science.gov (United States)

    Patel, Z; Söderström, P-A; Podolyák, Zs; Regan, P H; Walker, P M; Watanabe, H; Ideguchi, E; Simpson, G S; Liu, H L; Nishimura, S; Wu, Q; Xu, F R; Browne, F; Doornenbal, P; Lorusso, G; Rice, S; Sinclair, L; Sumikama, T; Wu, J; Xu, Z Y; Aoi, N; Baba, H; Bello Garrote, F L; Benzoni, G; Daido, R; Fang, Y; Fukuda, N; Gey, G; Go, S; Gottardo, A; Inabe, N; Isobe, T; Kameda, D; Kobayashi, K; Kobayashi, M; Komatsubara, T; Kojouharov, I; Kubo, T; Kurz, N; Kuti, I; Li, Z; Matsushita, M; Michimasa, S; Moon, C-B; Nishibata, H; Nishizuka, I; Odahara, A; Şahin, E; Sakurai, H; Schaffner, H; Suzuki, H; Takeda, H; Tanaka, M; Taprogge, J; Vajta, Zs; Yagi, A; Yokoyama, R

    2014-12-31

    Excited states in the N=102 isotones 166Gd and 164Sm have been observed following isomeric decay for the first time at RIBF, RIKEN. The half-lives of the isomeric states have been measured to be 950(60) and 600(140) ns for 166Gd and 164Sm, respectively. Based on the decay patterns and potential energy surface calculations, including β6 deformation, a spin and parity of 6- has been assigned to the isomeric states in both nuclei. Collective observables are discussed in light of the systematics of the region, giving insight into nuclear shape evolution. The decrease in the ground-band energies of 166Gd and 164Sm (N=102) compared to 164Gd and 162Sm (N=100), respectively, presents evidence for the predicted deformed shell closure at N=100.

  15. Isomer Decay Spectroscopy of Sm 164 and Gd 166 : Midshell Collectivity Around N =100

    Science.gov (United States)

    Patel, Z.; Söderström, P.-A.; Podolyák, Zs.; Regan, P. H.; Walker, P. M.; Watanabe, H.; Ideguchi, E.; Simpson, G. S.; Liu, H. L.; Nishimura, S.; Wu, Q.; Xu, F. R.; Browne, F.; Doornenbal, P.; Lorusso, G.; Rice, S.; Sinclair, L.; Sumikama, T.; Wu, J.; Xu, Z. Y.; Aoi, N.; Baba, H.; Bello Garrote, F. L.; Benzoni, G.; Daido, R.; Fang, Y.; Fukuda, N.; Gey, G.; Go, S.; Gottardo, A.; Inabe, N.; Isobe, T.; Kameda, D.; Kobayashi, K.; Kobayashi, M.; Komatsubara, T.; Kojouharov, I.; Kubo, T.; Kurz, N.; Kuti, I.; Li, Z.; Matsushita, M.; Michimasa, S.; Moon, C.-B.; Nishibata, H.; Nishizuka, I.; Odahara, A.; Şahin, E.; Sakurai, H.; Schaffner, H.; Suzuki, H.; Takeda, H.; Tanaka, M.; Taprogge, J.; Vajta, Zs.; Yagi, A.; Yokoyama, R.

    2014-12-01

    Excited states in the N =102 isotones Gd 166 and Sm 164 have been observed following isomeric decay for the first time at RIBF, RIKEN. The half-lives of the isomeric states have been measured to be 950(60) and 600(140) ns for Gd 166 and Sm 164 , respectively. Based on the decay patterns and potential energy surface calculations, including β6 deformation, a spin and parity of 6- has been assigned to the isomeric states in both nuclei. Collective observables are discussed in light of the systematics of the region, giving insight into nuclear shape evolution. The decrease in the ground-band energies of Gd 166 and Sm 164 (N =102 ) compared to Gd 164 and Sm 162 (N =100 ), respectively, presents evidence for the predicted deformed shell closure at N =100 .

  16. Principle of a liquid nitrogen irradiation device and its realization for use in a swimming-pool type reactor

    International Nuclear Information System (INIS)

    Bochirol, L.; Doulat, J.; Weil, L.

    1961-01-01

    The problem of pile irradiation of samples immersed in liquid nitrogen has been solved with total elimination of explosion hazards and high reliability (no moving parts). The principle of the device is that of a double bath: one of high purity nitrogen cools the samples at the level of the core; a second of commercial nitrogen is located above the first one, outside the high radiation field, and works as a continuous condenser for the pure nitrogen, the flow-back of which is provided simply by gravity. The apparatus described in detail here has been designed for a swimming-pool pile. It was so designed as to provide absolute protection against radiations and to allow the irradiated samples to be easily removed in the cold condition. This apparatus has been in operation for several months. In a fast flux greater than 10 13 neutrons/cm 2 .s and a γ-flux of the order of 10 8 roentgens/h, the consumption of liquid nitrogen is of the order of 100 liters a day. (author) [fr

  17. 40 CFR 166.49 - Public notice of crisis exemptions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Public notice of crisis exemptions... PROGRAMS EXEMPTION OF FEDERAL AND STATE AGENCIES FOR USE OF PESTICIDES UNDER EMERGENCY CONDITIONS Crisis Exemptions § 166.49 Public notice of crisis exemptions. (a) Periodic notices. At least quarterly, the...

  18. Optically controlled multiple switching operations of DNA biopolymer devices

    International Nuclear Information System (INIS)

    Hung, Chao-You; Tu, Waan-Ting; Lin, Yi-Tzu; Fruk, Ljiljana; Hung, Yu-Chueh

    2015-01-01

    We present optically tunable operations of deoxyribonucleic acid (DNA) biopolymer devices, where a single high-resistance state, write-once read-many-times memory state, write-read-erase memory state, and single low-resistance state can be achieved by controlling UV irradiation time. The device is a simple sandwich structure with a spin-coated DNA biopolymer layer sandwiched by two electrodes. Upon irradiation, the electrical properties of the device are adjusted owing to a phototriggered synthesis of silver nanoparticles in DNA biopolymer, giving rise to multiple switching scenarios. This technique, distinct from the strategy of doping of pre-formed nanoparticles, enables a post-film fabrication process for achieving optically controlled memory device operations, which provides a more versatile platform to fabricate organic memory and optoelectronic devices

  19. Optically controlled multiple switching operations of DNA biopolymer devices

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Chao-You; Tu, Waan-Ting; Lin, Yi-Tzu [Institute of Photonics Technologies, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Fruk, Ljiljana [Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA (United Kingdom); Hung, Yu-Chueh, E-mail: ychung@ee.nthu.edu.tw [Institute of Photonics Technologies, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Department of Electrical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2015-12-21

    We present optically tunable operations of deoxyribonucleic acid (DNA) biopolymer devices, where a single high-resistance state, write-once read-many-times memory state, write-read-erase memory state, and single low-resistance state can be achieved by controlling UV irradiation time. The device is a simple sandwich structure with a spin-coated DNA biopolymer layer sandwiched by two electrodes. Upon irradiation, the electrical properties of the device are adjusted owing to a phototriggered synthesis of silver nanoparticles in DNA biopolymer, giving rise to multiple switching scenarios. This technique, distinct from the strategy of doping of pre-formed nanoparticles, enables a post-film fabrication process for achieving optically controlled memory device operations, which provides a more versatile platform to fabricate organic memory and optoelectronic devices.

  20. low dose irradiation growth in zirconium

    International Nuclear Information System (INIS)

    Fortis, A.M.

    1987-01-01

    Low dose neutron irradiation growth in textured and recrystallized zirconium, is studied, at the Candu Reactors Calandria temperature (340 K) and at 77 K. It was necessary to design and build 1: A facility to irradiate at high temperatures, which was installed in the Argentine Atomic Energy Commission's RA1 Reactor; 2: Devices to carry out thermal recoveries, and 3: Devices for 'in situ' measurements of dimensional changes. The first growth kinetics curves were obtained at 365 K and at 77 K in a cryostat under neutron fluxes of similar spectra. Irradiation growth experiments were made in zirconium doped with fissionable material (0,1 at % 235 U). In this way an equivalent dose two orders of magnitude greater than the reactor's fast neutrons dose was obtained, significantly reducing the irradiation time. The specimens used were bimetallic couples, thus obtaining a great accuracy in the measurements. The results allow to determine that the dislocation loops are the main cause of irradiation growth in recrystallized zirconium. Furthermore, it is shown the importance of 'in situ' measurements as a way to avoid the effect that temperature changes have in the final growth measurement; since they can modify the residual stresses and the overconcentrations of defects. (M.E.L.) [es

  1. Evaluation of two intracavitary high-dose-rate brachytherapy devices for irradiating additional and irregularly shaped volumes of breast tissue

    International Nuclear Information System (INIS)

    Lu, Sharon M.; Scanderbeg, Daniel J.; Barna, Patrick; Yashar, William; Yashar, Catheryn

    2012-01-01

    The SAVI and Contura breast brachytherapy applicators represent 2 recent advancements in brachytherapy technology that have expanded the number of women eligible for accelerated partial breast irradiation in the treatment of early-stage breast cancer. Early clinical experience with these 2 single-entry, multichannel high-dose-rate brachytherapy devices confirms their ease of use and dosimetric versatility. However, current clinical guidelines for SAVI and Contura brachytherapy may result in a smaller or less optimal volume of treated tissue compared with traditional interstitial brachytherapy. This study evaluates the feasibility of using the SAVI and Contura to irradiate larger and irregularly shaped target volumes, approaching what is treatable with the interstitial technique. To investigate whether additional tissue can be treated, 17 patients treated with the SAVI and 3 with the Contura were selected. For each patient, the planning target volume (PTV) was modified to extend 1.1 cm, 1.3 cm, and 1.5 cm beyond the tumor bed cavity. To evaluate dose conformance to an irregularly shaped target volume, 9 patients treated with the SAVI and 3 with the Contura were selected from the original 20 patients. The following asymmetric PTV margin combinations were assessed for each patient: 1.5/0.3, 1.3/0.3, and 1.1/0.3 cm. For all patients, treatment planning was performed, adopting the National Surgical Adjuvant Breast and Bowel Project guidelines, and dosimetric comparisons were made. The 6–1 and 8–1 SAVI devices can theoretically treat a maximal tissue margin of 1.5 cm and an asymmetric PTV with margins ranging from 0.3 to 1.5 cm. The 10–1 SAVI and Contura can treat a maximal margin of 1.3 cm and 1.1 cm, respectively, and asymmetric PTV with margins ranging from 0.3–1.3 cm. Compared with the Contura, the SAVI demonstrated greater dosimetric flexibility. Risk of developing excessive hot spots increased with the size of the SAVI device. Both the SAVI and Contura

  2. A gauge device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1982-01-01

    A readily transportable device of relative light weight comprising a pair of tensioned guides for providing accurate and stable reference planes. An embodiment comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a pair of arcuate compression members. The tensioned guides provide planes of reference for measuring devices moved therealong adjacent to a component to be measured. The device is especially useful for making on-site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (author)

  3. Structure and application of galvanomagnetic devices

    CERN Document Server

    Weiss, H

    1969-01-01

    International Series of Monographs on Semiconductors, Volume 8: Structure and Application of Galvanomagnetic Devices focuses on the composition, reactions, transformations, and applications of galvanomagnetic devices. The book first ponders on basic physical concepts, design and fabrication of galvanomagnetic devices, and properties of galvanomagnetic devices. Discussions focus on changes in electrical properties on irradiation with high-energy particles, magnetoresistor field-plate, Hall generator, preparation of semiconductor films by vacuum deposition, structure of field-plate magnetoresist

  4. CERN IRRADIATION FACILITIES.

    Science.gov (United States)

    Pozzi, Fabio; Garcia Alia, Ruben; Brugger, Markus; Carbonez, Pierre; Danzeca, Salvatore; Gkotse, Blerina; Richard Jaekel, Martin; Ravotti, Federico; Silari, Marco; Tali, Maris

    2017-09-28

    CERN provides unique irradiation facilities for applications in dosimetry, metrology, intercomparison of radiation protection devices, benchmark of Monte Carlo codes and radiation damage studies to electronics. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Design of Shanghai irradiation center

    International Nuclear Information System (INIS)

    Chen Fugen; Lu Zhongwen; Xue Xiangrong; Yao Zewu; Du Bende; Xu Zhicheng; Du Kangsen

    1988-01-01

    Shanghai Irradiation Center, situated in westrn suburb of Shanghai, was completed in August, 1986. At present, a 6.55 x 10 15 Bq 60 Co source has been loaded, though the designed activity of maximum loading is 18.5 x 10 10 Bq. the center is designed mainly for irradiation preservation of food and sterilization of medical devices and tools. Its processing ability is 10 t/h for potatoes

  6. Isolation and expression analysis of four HD-ZIP III family genes targeted by microRNA166 in peach.

    Science.gov (United States)

    Zhang, C H; Zhang, B B; Ma, R J; Yu, M L; Guo, S L; Guo, L

    2015-10-30

    MicroRNA166 (miR166) is known to have highly conserved targets that encode proteins of the class III homeodomain-leucine zipper (HD-ZIP III) family, in a broad range of plant species. To further understand the relationship between HD-ZIP III genes and miR166, four HD-ZIP III family genes (PpHB14, PpHB15, PpHB8, and PpREV) were isolated from peach (Prunus persica) tissue and characterized. Spatio-temporal expression profiles of the genes were analyzed. Genes of the peach HD-ZIP III family were predicted to encode five conserved domains. Deduced amino acid sequences and tertiary structures of the four peach HD-ZIP III genes were highly conserved, with corresponding genes in Arabidopsis thaliana. The expression level of four targets displayed the opposite trend to that of miR166 throughout fruit development, with the exception of PpHB14 from 35 to 55 days after full bloom (DAFB). This finding indicates that miR166 may negatively regulate its four targets throughout fruit development. As for leaf and phloem, the same trend in expression level was observed between four targets and miR166 from 75 to 105 DAFB. However, the opposite trend was observed for the transcript level between four targets and miR166 from 35 to 55 DAFB. miRNA166 may negatively regulate four targets in some but not all developmental stages for a given tissue. The four genes studied were observed to have, exactly or generally, the same change tendency as individual tissue development, a finding that suggests genes of the HD-ZIP III family in peach may have complementary or cooperative functions in various tissues.

  7. Cell Adhesion Molecule CD166/ALCAM Functions Within the Crypt to Orchestrate Murine Intestinal Stem Cell HomeostasisSummary

    Directory of Open Access Journals (Sweden)

    Nicholas R. Smith

    2017-05-01

    Full Text Available Background & Aims: Intestinal epithelial homeostasis is maintained by active-cycling and slow-cycling stem cells confined within an instructive crypt-based niche. Exquisite regulating of these stem cell populations along the proliferation-to-differentiation axis maintains a homeostatic balance to prevent hyperproliferation and cancer. Although recent studies focus on how secreted ligands from mesenchymal and epithelial populations regulate intestinal stem cells (ISCs, it remains unclear what role cell adhesion plays in shaping the regulatory niche. Previously we have shown that the cell adhesion molecule and cancer stem cell marker, CD166/ALCAM (activated leukocyte cell adhesion molecule, is highly expressed by both active-cycling Lgr5+ ISCs and adjacent Paneth cells within the crypt base, supporting the hypothesis that CD166 functions to mediate ISC maintenance and signal coordination. Methods: Here we tested this hypothesis by analyzing a CD166–/– mouse combined with immunohistochemical, flow cytometry, gene expression, and enteroid culture. Results: We found that animals lacking CD166 expression harbored fewer active-cycling Lgr5+ ISCs. Homeostasis was maintained by expansion of the transit-amplifying compartment and not by slow-cycling Bmi1+ ISC stimulation. Loss of active-cycling ISCs was coupled with deregulated Paneth cell homeostasis, manifested as increased numbers of immature Paneth progenitors due to decreased terminal differentiation, linked to defective Wnt signaling. CD166–/– Paneth cells expressed reduced Wnt3 ligand expression and depleted nuclear β-catenin. Conclusions: These data support a function for CD166 as an important cell adhesion molecule that shapes the signaling microenvironment by mediating ISC–niche cell interactions. Furthermore, loss of CD166 expression results in decreased ISC and Paneth cell homeostasis and an altered Wnt microenvironment. Keywords: Intestinal Stem Cell, Homeostasis

  8. Prognostic value of CD166 expression in cancers of the digestive system: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Chao Ni

    Full Text Available Many studies have reported the prognostic predictive value of CD166 as a cancer stem cell marker in cancers of the digestive system; however, its predictive value remains controversial. Here, we investigate the correlation between CD166 positivity in digestive system cancers and clinicopathological features using meta-analysis.A comprehensive search in PubMed and ISI Web of Science through March of 2013 was performed. Only articles containing CD166 antigen immunohistochemical staining in cancers of the digestive system were included,including pancreatic cancer, esophageal cancer, gastric cancer and colorectal cancer. Data comparing 3- and 5-year overall survival along with other clinicopathological features were collected.Nine studies with 2553 patients who met the inclusion criteria were included for the analysis. The median rate of CD166 immunohistochemical staining expression was 56% (25.4%-76.3%. In colorectal cancer specifically, the results of a fixed-effects model indicated that CD166-positive expression was an independent marker associated with a smaller tumor burden (T category; RR = 0.93, 95%, CI: 0.88-0.98 but worse spread to nearby lymph nodes (N category; RR = 1.17, 95% CI: 1.05-1.30. The 5-year overall survival rate was showed relationship with cytoplasmic positive staining of CD166 (RR = 1.47 95% 1.21-1.79, but no significant association was found in the pool or any other stratified analysis with 3- or 5- year overall survival rate.Based on the published studies, different cellular location of CD166 has distinct prognostic value and cytoplasmic positive expression is associated with worse prognosis outcome. Besides, our results also find CD166 expression indicate advanced T category and N-positive status in colorectal cancer specifically.

  9. Irradiation damages of semiconductor devices and their improvement

    Energy Technology Data Exchange (ETDEWEB)

    Uwatoko, Yoshiya [Saitama Univ., Urawa (Japan); Ohyama, Hidenori; Hayama, Kiyoteru; Hakata, Tetsuya; Kudou, Tomohiro

    1998-01-01

    In this study, effect of radiation on semiconductor devices was evaluated at both sides of electrical and crystalline properties for two years from 1995 fiscal years. And, damage of Si(sub 1-x)Ge(sub x) device was considered at viewpoints of Ge content and sprung-out atomic number and non ionization energy loss of constituting atom formed by radiation on its radiation source dependency of damage. This paper was a report on proton beam damage of the Si(sub 1-x)Ge(sub x) device, neutron damage of InGaAs photodiode, and effect of Ga content and kinds of beam on their damages. (G.K.)

  10. Lifting devices in nuclear facilities

    International Nuclear Information System (INIS)

    The rule is valid for lifts, cranes, winches, rail travel trolleys, load lifting devices and fuel element changing devices for light-water reactors, insofar as these are used in plants to produce or to fission nuclear fuels or to process irradiated nuclear fuels or in the storage or other use of nuclear fuels. (LH) [de

  11. Device for electron beam machining

    International Nuclear Information System (INIS)

    Panzer, S.; Ardenne, T. von; Liebergeld, H.

    1984-01-01

    The invention concerns a device for electron beam machining, in particular welding. It is aimed at continuous operation of the electron irradiation device. This is achieved by combining the electron gun with a beam guiding chamber, to which vacuum chambers are connected. The working parts to be welded can be arranged in the latter

  12. Extracorporeal irradiation -Physicist perspective

    International Nuclear Information System (INIS)

    Vijayaprabhu, N.; Saravanan, K.S.; Gunaseelan; Vivekanandam, S.; Reddy, K.S.; Parthasarathy; Mourougan, S.; Elangovan, K.

    2008-01-01

    Extracorporeal irradiation (ECI) involves irradiation of body tissues, particularly malignant bones of the extremities, outside the body. This involves en bloc resection of the tumour, extracorporeal irradiation of the bone segment with a single dose of 50 Gy or more, and reimplantation of the irradiated bone with fixation devices. Bone tumours like Ewing's Sarcoma, Chondrosarcoma and Oesteosarcoma; in the involved sites like femur, tibia, humerus, ilium and sacrum can be treated with ECI. The reimplanted bone simply acts as a framework for appositional bone growth from surrounding healthy bones. The conventional indications for postoperative irradiation are still applied. The major advantages of ECI are the precise anatomic fit of the reimplanted bone segment, preservation of joint mobility and its potential in avoiding the growth discrepancy commonly seen in prosthetic replacement. The use of ECI was first described in 1968 and practiced in Australia since 1996. In our center, we have completed six ECIs

  13. Irradiation Testing of TRISO-Coated Particle Fuel in Korea

    International Nuclear Information System (INIS)

    Kim, Bong Goo; Yeo, Sunghwan; Jeong, Kyung-Chai; Eom, Sung-Ho; Kim, Yeon-Ku; Kim, Woong Ki; Lee, Young Woo; Cho, Moon Sung; Kim, Yong Wan

    2014-01-01

    In Korea, coated particle fuel is being developed to support development of a VHTR. At the end of March 2014, the first irradiation test in HANARO at KAERI to demonstrate and qualify TRISO-coated particle fuel for use in a VHTR was terminated. This experiment was conducted in an inert gas atmosphere without on-line temperature monitoring and control, or on-line fission product monitoring of the sweep gas. The irradiation device contained two test rods, one has nine fuel compacts and the other five compacts and eight graphite specimens. Each compact contains about 260 TRISO-coated particles. The duration of irradiation testing at HANARO was about 135 full power days from last August 2013. The maximum average power per particle was about 165 mW/particle. The calculated peak burnup of the TRISO-coated fuel was a little less than 4 atom percent. Post-irradiation examination is being carried out at KAERI’s Irradiated Material Examination Facility beginning in September of 2014. This paper describes characteristics of coated particle fuel, the design of the test rod and irradiation device for this coated particle fuel, and discusses the technical results of irradiation testing at HANARO. (author)

  14. Irradiation testing of coated particle fuel at Hanaro

    International Nuclear Information System (INIS)

    Goo Kim, Bong; Sung Cho, Moo; Kim, Yong Wan

    2014-01-01

    TRISO-coated particle fuel is developing to support development of VHTR in Korea. From August 2013, the first irradiation testing of coated particle fuel was begun to demonstrate and qualify TRISO fuel for use in VHTR in the HANARO at KAERI. This experiment is currently undergoing under the atmosphere of a mixed inert gas without on-line temperature monitoring and control combined with on-line fission product monitoring of the sweep gas. The irradiation device contains two test rods, one contains nine fuel compacts and the other five compacts and eight graphite specimens. Each compact has 263 coated particles. After a peak burn-up of about 4 at% and a peak fast neutron fluence of about 1.7 x 10 21 n/cm 2 , PIE will be carried out at KAERI's Irradiated Material Examination Facility. This paper is described characteristics of coated particle fuel, the design of test rod and irradiation device for coated particle fuel, discusses the technical results for irradiation testing at HANARO. (authors)

  15. Gamma-irradiation of tomatoes

    International Nuclear Information System (INIS)

    Tencheva, S.; Todorov, S.

    1975-01-01

    The influence of gamma-ray on tomatoes picked in a pink-red ripening stage, good for consumption, is studied. For that purpose tomatoes of ''Pioneer 2'' variety packed in perforated 500 g plastic bags were irradiated on a gamma device (Cobalt-60) at a dose power of 1900 rad/min with doses 200 or 300 krad. Samples were stored after irradiation at room temperature (20 - 22sup(o)C). Microbiological studies demonstrated that 44 resp. 99.96 per cent of the initial number of microorganisms was destroyed after irradiation with 200 resp. 300 krad. The time required for the number of microorganisms to be restored was accordingly increased. Irradiation delayed tomato ripening by 4 to 6 days, demonstrable by the reduced content of the basic staining substances - carotene and licopine. Immediately after irradiation the ascorbic acid content was reduced by an average of 13 per cent. After 18 days the amount of ascorbic acid in irradiated tomatoes was increased to a higher than the starting level, this is attributed to reductone formation during irradiation. The elevated total sugar content shown to be invert sugar was due to further tomato ripening. (Ch.K.)

  16. Formation of silver microbelt structures by laser irradiation of silver nanoparticles in ethanol

    Directory of Open Access Journals (Sweden)

    Zamiri R

    2011-10-01

    Full Text Available Reza Zamiri1, Azmi Zakaria1,2, Mohd Shahril Husin1, Zaidan Abd Wahab1, Forough Kalaei Nazarpour3 1Department of Physics, Faculty of Science, 2Advanced Materials and Nanotechnology Laboratory, Institute of Advanced Technology, 3Institute of Bioscience, Universiti Putra Malaysia, Serdang, Selangor, Malaysia Abstract: In the present work, we prepared silver nanoparticles by laser ablation of pure silver plate in ethanol and then irradiated the silver nanoparticles using a 532 nm Q-switched Nd:YAG pulsed laser. Transmission electron microscopic images of the sample after irradiation clearly showed formation of big structures, such as microrods and microbelts in ethanol. The obtained microbelts had a width of about 0.166 µm and a length of 1.472 µm. The reason for the formation of such a big structure is the tendency of the nanoparticles to aggregate in ethanol before irradiation, which causes fusion of the nanoparticles. Keywords: nanomaterial, laser ablation, nanoparticles

  17. Inspection and repairing method and device for inside of nuclear reactor

    International Nuclear Information System (INIS)

    Ito, Shin; Yuguchi, Yasuhiro; Sato, Katsuhiko

    1996-01-01

    A swimming robot handling device is disposed on a floor of a reactor pit floor or a reactor floor. A swimming robot is connected to a winding device of a composite cable incorporating optical fibers. The swimming robot comprises a robot propulsion device for propelling the robot itself, a laser beam irradiating optical device for irradiating pulsative laser beams introduced by an optical fiber and an antenna mechanism having ultrasonic probe in an antenna-like shape. The swimming robot is lowered in a reactor filled with water and caused to swim to a portion to be welded, and pulsative laser beams are irradiated to the portion to be welded in a state where the antenna mechanism is brought into contact with the portion to be welded to improve the state of stresses on the surface. Further, the ultrasonic oscillations generated upon irradiation of the laser beams are measured using the ultrasonic probe to perform physical inspection. The surface of the portion to be welded can be modified or repaired stably and efficiently by remote control. (N.H.)

  18. Single-Event Effects in Power MOSFETs During Heavy Ion Irradiations Performed After Gamma-Ray Degradation

    Science.gov (United States)

    Busatto, G.; De Luca, V.; Iannuzzo, F.; Sanseverino, A.; Velardi, F.

    2013-10-01

    The robustness of commercial power metal-oxide semiconductor field-effect transistors to combined gamma-heavy ion irradiation has been investigated, evidence that the degradation of the gate oxide caused by the γ irradiation can severely corrupt the robustness to single-event effects and drastically modify the physical behavior of the device under test after the impact of a heavy ion. A decrease of the critical voltages at which destructive burnouts and gate ruptures for heavy ion impact appear, has been detected in the devices under test, which were previously irradiated with γ rays. In addition, the amount of critical voltage reduction is strictly related to the amount of the absorbed γ-ray dose. Furthermore, at the failure voltage, the behavior of the device is affected by the conduction of a current through the gate oxide. Moreover, the single-event gate rupture” of the device appears at lower voltages because of the reduction of the Fowler-Nordheim limit in the γ-irradiated devices.

  19. Evidence for the involvement of Ala 166 in coupling Na(+) to sugar transport through the human Na(+)/glucose cotransporter

    DEFF Research Database (Denmark)

    Meinild, A K; Loo, D D; Hirayama, B A

    2001-01-01

    . The affinity for Na(+) was unchanged compared to that of hSGLT1, whereas the sugar affinity was reduced and sugar specificity was altered. There was a reduction in the turnover rate of the transporter, and in contrast to that of hSGLT1, the turnover rate depended on the sugar molecule. Exposure of A166C......We mutated residue 166, located in the putative Na(+) transport pathway between transmembrane segments 4 and 5 of human Na(+)/glucose cotransporter (hSGLT1), from alanine to cysteine (A166C). A166C was expressed in Xenopus laevis oocytes, and electrophysiological methods were used to assay function...... to MTSEA and MTSET, but not MTSES, abolished sugar transport. Accessibility of A166C to alkylating reagents was independent of protein conformation, indicating that the residue is always accessible from the extracellular surface. Sugar and phlorizin did not protect the residue from being alkylated...

  20. The E166 experiment: Development of an undulator-based ...

    Indian Academy of Sciences (India)

    A longitudinal polarized positron beam is foreseen for the international linear collider (ILC). A proof-of-principle experiment has been performed in the final focus test beam at SLAC to demonstrate the production of polarized positrons for implementation at the ILC. The E166 experiment uses a 1 m long helical undulator in a ...

  1. 27 CFR 40.166 - Default, prepayment of tax required.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 2 2010-04-01 2010-04-01 false Default, prepayment of tax... Payment of Taxes on Tobacco Products § 40.166 Default, prepayment of tax required. Where a check or money... tax due thereunder, or where a manufacturer is otherwise in default in payment of tax on tobacco...

  2. Automatized target devices for radioisotope production at the RITs cyclotron

    International Nuclear Information System (INIS)

    Bogdanov, P.V.; Ivanov, V.V.; Karasev, B.G.

    1981-01-01

    An automation target device intended for isotope production on the internal beam of the RITs cyclotron is decribed. The target device comprises the following main units: target head, vacuum lock, charging device, transport system for bringing the target for charging; mechanism of target discharge transport device, control interlocking and signalling control system of target radiation power. The automation target device permits radioisotope production on the cyclotron in commercial scales with automation substitution of irradiated targets. The time of substitution of one of six targets makes up only 5 min. The time of charging a new group of targets to the charge device - 60 min. Contact of the personnel with irradiated targets is practically excluded and the necessity of entering the cyclotron room for maintenance of the plant is reduced to the minimum [ru

  3. Experimental dosimetry of Ho-166 bioglass seed polymer-protected

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luciana B.; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This study aims to develop experimental dosimetry of Ho-166 bio glass seed for brachytherapy studies using GAFCHROMIC EBT2 radio chromium films. The methodology consists of placement of radio chromium films in a compressed breast phantom, along with bio glass polymer-protected seeds of [Si: Ca: Ho] and [Si: Ca: Ho: Zr]. The bio glass seeds were encapsulated with polyvinyl alcohol, before being activated and used in the study. The bio glass seeds were introduced into the breast phantom, along with radio chromium films for a period of 2 hours. After the exposure time, radio chromium films were removed from phantom and digitized for analysis in ImageDIG 2.0 program, which quantifies the intensity of RGB (Red, Green, Blue). The dose calculation was evaluated by Monte Carlo technique. Experimental and theoretical data were used to calibrate the dose distribution. The results were plotted on graphs and dose iso curves were obtained. As conclusion it is possible to perform dosimetry in Ho-166 seed brachytherapy using radio chromium films, limited to a short exposure time and small activity. (author)

  4. Experimental dosimetry of Ho-166 bioglass seed polymer-protected

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Campos, Tarcisio P.R.

    2011-01-01

    This study aims to develop experimental dosimetry of Ho-166 bio glass seed for brachytherapy studies using GAFCHROMIC EBT2 radio chromium films. The methodology consists of placement of radio chromium films in a compressed breast phantom, along with bio glass polymer-protected seeds of [Si: Ca: Ho] and [Si: Ca: Ho: Zr]. The bio glass seeds were encapsulated with polyvinyl alcohol, before being activated and used in the study. The bio glass seeds were introduced into the breast phantom, along with radio chromium films for a period of 2 hours. After the exposure time, radio chromium films were removed from phantom and digitized for analysis in ImageDIG 2.0 program, which quantifies the intensity of RGB (Red, Green, Blue). The dose calculation was evaluated by Monte Carlo technique. Experimental and theoretical data were used to calibrate the dose distribution. The results were plotted on graphs and dose iso curves were obtained. As conclusion it is possible to perform dosimetry in Ho-166 seed brachytherapy using radio chromium films, limited to a short exposure time and small activity. (author)

  5. Craniospinal versus whole brain irradiation in Medulloblastoma patients, with introduction of utilizing a simple immobilization device

    Directory of Open Access Journals (Sweden)

    Haddad P

    2001-05-01

    Full Text Available Craniospinal irradiation plus posterior fossa boost (CS1 is the standard modality of post-operative treatment of patient with medulloblastoma, but considering the technical difficulties and limited facilities, often whole- brain irradiation plus posterior fossa boost (WBI had been used in our institution until 1991. Tust a retrospective study was undertaken to compare the patients treated by By WBI and CSI for recurrences and disease-free survival (DFS. Files of all medullobalstoma patients treated post-operatively in our department in the 10 – year period of 1986-1996 were reviewed. To obtain the best possible follow- up, a formal inquiry letter was mailed to all patients’ addresses.Total of 72 patients had been treated, with a mean age of 14.7 years and male-to-female ratio of 1.5:1 Thirty –seven patients had been treated by WBI and 35 by CS. A simple wooden device designed and made in our department was used for CSI patients’ set-up and immobilization. Mean radiation dose to posterior fossa was 4, 765 cGy in WBT and 5, 071 cGY in CSI (180-200 cGy fractions. Sixty-two patients (85% came back for follow-up, with 24 recurrences. Only 24% of CSI patients had recurrences, versus 51% in WBI Nearly all Wbi recurrences versus half of the CSI recurrences were spinal. DFS was 39 months in CSI and 26 months in WBI (P<0.001 . in multi-factorial analysis, only the extent of radiation (CSI versus WBI, P<0.001 was statistically significant. Mean age in our patients was higher than what is commonly reported in literature. The immobilization device introduce was a simple and useful accessory to CSI. Considering DFS, CSI in our department was acceptabley comparable to literature results and significantly superior to WBI. With regard to relatively high spinal recurrence rate even in CSI, the importance of suitable spinal cytological and imaging evaluation is again emphasized.

  6. Radiation Characterization of Commercial GaN Devices

    Science.gov (United States)

    Harris, Richard D.; Scheick, Leif Z.; Hoffman, James P.; Thrivikraman, Tushar; Jenabi, Masud; Gim, Yonggyu; Miyahira, Tetsuo

    2011-01-01

    Radiative feedback from primordial protostars and final mass of the first star Commercially available devices fabricated from GaN are beginning to appear from a number of different suppliers. Based on previous materials and prototype device studies, it is expected that these commercial devices will be quite tolerant to the types of radiation encountered in space. This expectation needs to be verified and the study described herein was undertaken for that purpose. All of the parts discussed in this report are readily available commercially. The parts chosen for study are all targeted for RF applications. Three different studies were performed: 1) a preliminary DDD/TID test of a variety of part types was performed by irradiating with 50 MeV protons, 2) a detailed DDD/TID study of one particular part type was performed by irradiating with 50 MeV protons, and 3) a SEB/SEGR test was performed on a variety of part types by irradiating with heavy ions. No significant degradation was observed in the tests performed in this study.

  7. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  8. Simulation of continious radiation effect on semiconductors by the pulse irradiation

    International Nuclear Information System (INIS)

    Radyuk, I.A.; Fejgin, O.O.; Shein, O.V.

    1986-01-01

    The problem of the laboratory radiation modelling of semiconductor devices and integrated circuits has been under consideration. The condition of adequacy of influencing the pulsed and continuous irradiation semiconductor devices and integrated circuits have been established. The methods of comparing and calculating the influences have been discussed. A number of expressions describing the connection between the parameters of impulced and continuous irradiation have been considered

  9. Improvements in or relating to semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Pepper, M

    1981-08-26

    A method of testing a field effect device for radiation hardness is described which does not involve irradiating the device. In a low temperature environment the conductance of the device is measured as a function of gate voltage at a first and at a second different substrate bias potential and by comparing the two an assessment of radiation hardness is made.

  10. Study of radiation effects on semiconductor devices

    International Nuclear Information System (INIS)

    Kuboyama, Satoshi; Shindou, Hiroyuki; Ikeda, Naomi; Iwata, Yoshiyuki; Murakami, Takeshi

    2004-01-01

    Fine structure of the recent semiconductor devices has made them more sensitive to the space radiation environment with trapped high-energy protons and heavy ions. A new failure mode caused by bulk damage had been reported on such devices with small structure, and its effect on commercial synchronous dynamic random access memory (SDRAMs) was analyzed from the irradiation test results performed at Heavy ion Medical Accelerator in Chiba (HIMAC). Single event upset (SEU) data of static random access memory (SRAMs) were also collected to establish the method of estimating the proton-induced SEU rate from the results of heavy ion irradiation tests. (authors)

  11. SU-F-T-515: Increased Skin Dose in Supine Craniospinal Irradiation Due to Carbon Fiber Couch and Vacuum Bag Immobilization Device

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, D; Zhao, Z; Wang, X; Yang, J [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To measure the surface dose for supine craniospinal irradiation employing posterior beams, treating through an imaging couch and BlueBag immobilization device. Methods: The percentage depth dose (PDD) in the buildup region of a clinical 6 MV photon beam was measured using an Advanced Markus parallel plate ionization chamber in a solid water phantom. The PDD from a 10×10 cm{sup 2} anterior beam was measured at 100 cm SSD, simulating a traditional prone craniospinal technique. The measurements were compared to commissioning and treatment planning system data. The PDD was also measured in a posterior setup with the phantom surface laying directly on the Brainlab carbon fiber imaging couch, with the phantom surface 100 cm from the source, simulating a supine craniospinal setup. The posterior measurements were repeated with a BlueBag vacuum immobilization device between the couch and phantom, with thicknesses of 1.7 cm and 5 cm. The PDD from a 10×10 cm{sup 2} field and a typical 6×30 cm{sup 2} craniospinal field were also compared. The PDDs were normalized at 5 cm to reflect typical craniospinal prescription dose normalization. Results: The measured PDD curve from the anterior setup agreed well with commissioning and treatment planning data, with surface doses of 19.9%, 28.8% and 27.7%, respectively. The surface doses of the 10×10 cm{sup 2} and 6×30 cm{sup 2} fields delivered through the imaging couch were both 122.4%. The supine setup yielded surface doses of 122.4%, 121.6%, and 119.6% for the couch only, 1.7 cm bag, and 5 cm bag setups, respectively. Conclusion: Delivering craniospinal irradiation through a carbon fiber couch removes the majority of skin sparing. The addition of a vacuum bag immobilization device restores some skin sparing, but the magnitude of this effect is negligible.

  12. 75 MeV boron ion irradiation studies on Si PIN photodiodes

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakara Rao, Y.P.; Praveen, K.C. [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India); Rejeena Rani, Y. [Integrated Circuits Division, Bharat Electronics Limited, Bangalore 560013, Karnataka (India); Tripathi, Ambuj [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India); Gnana Prakash, A.P., E-mail: gnanap@hotmail.com [Department of Studies in Physics, University of Mysore, Manasagangotri, Mysore 570006 (India)

    2013-12-01

    The highly sensitive silicon PIN photodiodes were fabricated to use in radiation environments. The Si PIN photodiodes are coated with 150 nm silicon dioxide (SiO{sub 2}) as anti-reflective (AR) coating. The presence of AR coating on the performance of irradiated PIN photodiodes is studied up to a total dose of 10 Mrad. The effects of 75 MeV boron (B{sup 5+}) ions and {sup 60}Co gamma radiation on the I–V, C–V and spectral responses of PIN photodiodes were studied systematically to understand the radiation tolerance of the devices. The 75 MeV B{sup 5+} irradiation results are compared with {sup 60}Co gamma irradiated results in the same dose range for 1 mm × 1 mm and 10 mm × 10 mm active area PIN photodiodes. The irradiation results show that the ion irradiated PIN photodiodes show more degradation when compared {sup 60}Co gamma irradiated devices. The irradiation results are presented in this paper and the possible mechanism behind the degradation of photodiodes is also discussed in the paper.

  13. Effect of high-energy electron beam irradiation on the device characteristics of IGZO-based transparent thin film transistors

    International Nuclear Information System (INIS)

    Moon, Hye Ji; Oh, Hye Ran; Bae, Byung Seong; Yun, Eui Jung; Ryu, Min Ki; Cho, Kyoung Ik

    2012-01-01

    In this study, we investigated the effects of high-energy electron beam irradiation (HEEBI) on the device properties of indium-gallium-zinc-oxide (IGZO)-based transparent thin film transistors (TTFTs). The developed TTFTs had a top gate structure, which used IGZO and Al 2 O 3 films for the active layer and the gate dielectric, respectively. The developed TTFTs were treated with HEEBI in air at RT at an electron beam energy of 0.8 MeV and a dose of 1 x 10 14 electrons/cm 2 . Without the HEEBI treatment, the devices operated in depletion mode with a threshold voltage (V th ) of -11.25 V, a field-effect mobility (μ FE ) of 8.71 cm 2 /Vs, an on-off ratio (I on/off ) of 1.3 x 10 8 and a sub-threshold slope (SS) of 0.3 V/decade. A huge positive-shifted V th of -1 V, a very high μ FE of 420 cm 2 /Vs, a high I on/off of 6.1 x 10 8 , and a lower SS of 0.25 V/decade were achieved for the HEEBI-treated devices, suggesting that the device characteristics of the developed TTFTs were significantly improved by the HEEBI treatment. The best device characteristics, which include I on/off of 8.1 x 10 8 , SS of 0.25 V/decade, V th of +1 V, μ FE of 8.8 cm 2 /Vs, and operation in the enhancement mode without aging, were obtained for the samples that had been annealed after HEEBI treatment. On the basis of the experimental results, we believe that HEEBI treatment can be crucial to develop IGZO-based TFTs with high performance and long-term reliability.

  14. A fluence device for precise radiation dosimetry

    International Nuclear Information System (INIS)

    Arnott, R.G.T.; Peak, M.J.

    1979-01-01

    An instrument is described which has been designed to ensure precise positioning of samples and sensing devices in three dimensions at all times during irradiation procedures. The system, which is both robust and sensitive, overcomes difficulties experienced when slight variations in the positioning of a sample under irradiation results in large changes in fluence. (UK)

  15. Validation of gamma irradiator controls for quality and regulatory compliance

    International Nuclear Information System (INIS)

    Harding, R.B.; Pinteric, F.J.A.

    1995-01-01

    Since 1978 the U.S. Food and Drug Administration (FDA) has had both the legal authority and the current good manufacturing practice (CGMP) regulations in progress to require irradiator owners who process medical devices to produce evidence of Irradiation Process Validation. One of the key components of Irradiation Process Validation is the validation of the irradiator controls. However it is only recently that FDA audits have focussed on this component of the process validation. (author)

  16. 25 CFR 166.100 - What special tribal policies will we apply to permitting on Indian agricultural lands?

    Science.gov (United States)

    2010-04-01

    ... preferences in permits advertised for bid under § 166.221 of this part, by allowing prospective Indian operators to match the highest responsible bid (unless the tribal law or leasing policy specifies some other... THE INTERIOR LAND AND WATER GRAZING PERMITS Tribal Policies and Laws Pertaining to Permits § 166.100...

  17. Large Object Irradiation Facility In The Tangential Channel Of The JSI TRIGA Reactor

    CERN Document Server

    Radulovic, Vladimir; Kaiba, Tanja; Kavsek, Darko; Cindro, Vladimir; Mikuz, Marko; Snoj, Luka

    2017-01-01

    This paper presents the design and installation of a new irradiation device in the Tangential Channel of the JSI TRIGA reactor in Ljubljana, Slovenia. The purpose of the device is to enable on-line irradiation testing of electronic components considerably larger in size (of lateral dimensions of at least 12 cm) than currently possible in the irradiation channels located in the reactor core, in a relatively high neutron flux (exceeding 10^12 n cm^-2 s^-1) and to provide adequate neutron and gamma radiation shielding.

  18. Multi-physic simulations of irradiation experiments in a technological irradiation reactor; Modelisation pluridisciplinaire d'experiences d'irradiation dans un reacteur d'irradiation technologique

    Energy Technology Data Exchange (ETDEWEB)

    Bonaccorsi, Th

    2007-09-15

    A Material Testing Reactor (MTR) makes it possible to irradiate material samples under intense neutron and photonic fluxes. These experiments are carried out in experimental devices localised in the reactor core or in periphery (reflector). Available physics simulation tools only treat, most of the time, one physics field in a very precise way. Multi-physic simulations of irradiation experiments therefore require a sequential use of several calculation codes and data exchanges between these codes: this corresponds to problems coupling. In order to facilitate multi-physic simulations, this thesis sets up a data model based on data-processing objects, called Technological Entities. This data model is common to all of the physics fields. It permits defining the geometry of an irradiation device in a parametric way and to associate information about materials to it. Numerical simulations are encapsulated into interfaces providing the ability to call specific functionalities with the same command (to initialize data, to launch calculations, to post-treat, to get results,... ). Thus, once encapsulated, numerical simulations can be re-used for various studies. This data model is developed in a SALOME platform component. The first application case made it possible to perform neutronic simulations (OSIRIS reactor and RJH) coupled with fuel behavior simulations. In a next step, thermal hydraulics could also be taken into account. In addition to the improvement of the calculation accuracy due to the physical phenomena coupling, the time spent in the development phase of the simulation is largely reduced and the possibilities of uncertainty treatment are under consideration. (author)

  19. Isomer Decay Spectroscopy of Sm-164 and Gd-166: Midshell Collectivity Around N=100

    OpenAIRE

    Patel, Z; Soederstroem, P-A; Podolyak, Z; Regan, PH; Walker, PM; Watanabe, H; Ideguchi, E; Simpson, GS; Liu, HL; Nishimura, S; Wu, Q; Xu, FR; Browne, F; Doornenbal, P; Lorusso, G

    2014-01-01

    © 2014 American Physical Society. Excited states in the N=102 isotones Gd166 and Sm164 have been observed following isomeric decay for the first time at RIBF, RIKEN. The half-lives of the isomeric states have been measured to be 950(60) and 600(140) ns for Gd166 and Sm164, respectively. Based on the decay patterns and potential energy surface calculations, including β6 deformation, a spin and parity of 6- has been assigned to the isomeric states in both nuclei. Collective observables are disc...

  20. Device for assessing radio-photoluminescence glasses

    International Nuclear Information System (INIS)

    Hoegl, A.; Schubert, K.

    1979-01-01

    The UV light irradiating the glass and the luminescence light caused by the UV light are collected in separate measuring paths. In order to correct the affect of changes of intensity of the UV light source on the amount of luminescence, both measuring paths are connected by programmed control, a comparison device and a correcting device. There are integrating stages in both measuring paths, which are followed by analogue digital converters with an assessment device. (DG) [de

  1. Dosimetric intercomparison of permanent Ho-166 seed's implants and HDR Ir-192 brachytherapy in breast cancer.

    Science.gov (United States)

    de Campos, Tarcisio Passos Ribeiro; Nogueira, Luciana Batista; Trindade, Bruno; Cuperschmid, Ethel Mizrahy

    2016-01-01

    To provide a comparative dosimetric analysis of permanent implants of Ho(166)-seeds and temporary HDR Ir(192)-brachytherapy through computational simulation. Brachytherapy with Ir(192)-HDR or LDR based on temporary wires or permanent radioactive seed implants can be used as dose reinforcement for breast radiation therapy. Permanent breast implants have not been a practical clinical routine; although, I(125) and Pd(103)-seeds have already been reported. Biodegradable Ho(166)-ceramic-seeds have been addressed recently. Simulations of implants of nine Ho(166)-seeds and equivalent with HDR Ir(192)-brachytherapy were elaborated in MCNP5, shaped in a computational multivoxel simulator which reproduced a female thorax phantom. Spatial dose rate distributions and dose-volume histograms were generated. Protocol's analysis involving exposure time, seed's activities and dose were performed. Permanent Ho(166)-seed implants presented a maximum dose rate per unit of contained activity (MDR) of 1.1601 μGy h(-1) Bq(-1); and, a normalized MDR in standard points (8 mm, equidistant to 03-seeds - SP1, 10 mm - SP2) of 1.0% (SP1) and 0.5% (SP2), respectively. Ir(192)-brachytherapy presented MDR of 4.3945 × 10(-3) μGy h(-1) Bq(-1); and, 30% (SP1), and 20% (SP2). Therefore, seed's implant activities of 333 MBq (Ho(166)) and 259 GBq (Ir(192)) produced prescribed doses of 58 Gy (SP1; 5d) and 56 Gy (SP1, 5 fractions, 6 min), respectively. Breast Ho(166)-implants of 37-111 MBq are attractive due to the high dose rate near 6-10 mm from seeds, equivalent to Ir(192)-brachytherapy of 259 GBq (3 fractions, 6 min) providing similar dose in standard points at a week; however, with spatial dose distribution better confined. The seed positioning can be adjusted for controlling the breast tumor, in stages I and II, in flat and deep tumors, without any breast volumetric limitation.

  2. Experimental study on gamma irradiation effects of floating gate ROMs The ROM is stated for Read-only Memory

    CERN Document Server

    He Chao Hui; Chen Xiao Hua; Wang Yan Ping; Peng Hong Lun

    2002-01-01

    Experimental results of gamma irradiation effects are given for Floating gate ROMs. There is an accumulated dose threshold. Errors occur when accumulated dose is above the threshold, no error occurs when below the threshold. The errors go up with the increase of the accumulated dose. Errors occur in devices that are measured during irradiation and irradiated in power on, moreover, new data cannot be written in these devices with programmer. However, under more accumulated dose, there is no error in devices in power off mode and new data can be written in these devices with programmer

  3. Noise characteristics of neutron images obtained by cooled CCD device

    International Nuclear Information System (INIS)

    Taniguchi, Ryoichi; Sasaki, Ryoya; Okuda, Shuichi; Okamoto, Ken-Ichi; Ogawa, Yoshihiro; Tsujimoto, Tadashi

    2009-01-01

    The noise characteristics of a cooled CCD device induced by neutron and gamma ray irradiation have been investigated. In the cooled CCD images, characteristic white spot noises (CCD noise) frequently appeared, which have a shape like a pixel in most cases and their brightness is extremely high compared with that of the image pattern. They could be divided into the two groups, fixed pattern noise (FPN) and random noise. The former always appeared in the same position in the image and the latter appeared at any position. In the background image, nearly all of the CCD noises were found to be the FPN, while many of them were the random noise during the irradiation. The random CCD noises increased with irradiation and decreased soon after the irradiation. In the case of large irradiation, a part of the CCD noise remained as the FPN. These facts suggest that the CCD noise is a phenomenon strongly relating to radiation damage of the CCD device.

  4. SU-E-T-557: Measuring Neutron Activation of Cardiac Devices Irradiated During Proton Therapy Using Indium Foils

    Energy Technology Data Exchange (ETDEWEB)

    Avery, S; Christodouleas, J; Delaney, K; Diffenderfer, E; Brown, K [University of Pennsylvania, Sicklerville, NJ (United States)

    2014-06-01

    Purpose: Measuring Neutron Activation of Cardiac devices Irradiated during Proton Therapy using Indium Foils Methods: The foils had dimensions of 25mm x 25mm x 1mm. After being activated, the foils were placed in a Canberra Industries well chamber utilizing a NaI(Tl) scintillation detector. The resulting gamma spectrum was acquired and analyzed using Genie 2000 spectroscopy software. One activation foil was placed over the upper, left chest of RANDO where a pacemaker would be. The rest of the foils were placed over the midline of the patient at different distances, providing a spatial distribution over the phantom. Using lasers and BBs to align the patient, 200 MU square fields were delivered to various treatment sites: the brain, the pancreas, and the prostate. Each field was shot at least a day apart, giving more than enough time for activity of the foil to decay (t1=2 = 54.12 min). Results: The net counts (minus background) of the three aforementioned peaks were used for our measurements. These counts were adjusted to account for detector efficiency, relative photon yields from decay, and the natural abundance of 115-In. The average neutron flux for the closed multi-leaf collimator irradiation was measured to be 1.62 x 106 - 0.18 x 106 cm2 s-1. An order of magnitude estimate of the flux for neutrons up to 1 keV from Diffenderfer et al. gives 3 x 106 cm2 s-1 which does agree on the order of magnitude. Conclusion: Lower energy neutrons have higher interaction cross-sections and are more likely to damage pacemakers. The thermal/slow neutron component may be enough to estimate the overall risk. The true test of the applicability of activation foils is whether or not measurements are capable of predicting cardiac device malfunction. For that, additional studies are needed to provide clinical evidence one way or the other.

  5. Efficacy and Safety of Semirigid Ureteroscopy Combined with Holmium: YAG Laser in the Treatment of Upper Urinary Tract Calculi: Is it a Good Alternative Treatment Option of Flexible Ureteroscopy for Developing Countries

    International Nuclear Information System (INIS)

    Bibi, S.; Siddiqui, T. R.; Ahmed, W.; Alam, S. E.; Shah, S. A.; Soomro, I. A.; Qureshi, S.

    2015-01-01

    Objective: To assess the success rates of endoscopic management of upper ureteral stones using semirigid ureterorenoscopy and holmium: YAG laser lithotripters. Method: A total of 74 patients with an established diagnosis of upper ureteric stone and scheduled for endoscopic ureteral stone treatment were retrospectively evaluated. Failure was defined as the inability to contact or fragment the stone, migration of the stone into the renal pelvis and difficulty in visualizing the stone for the second time. Success rates and influencing factors as for stone-free state were investigated. Results: Mean age of our patients was 45.99±15.00 (range: 24-82) years. In 14 of 74 patients procedural failure was observed. Double J stents were implanted in 65 percent of the patients and ureteral catheterization was performed on 20 percent of them. The total success rate was 81.1 percent. Major complication rate was 1.1 percent. Factors effecting the success rate as gender, age, body mass index, grade of hydronephrosis and stone size were evaluated and only age was found to be statistically significant. Conclusion: Despite some potential risks, semirigid ureterorenoscopic stone extraction and holmium: YAG laser lithotripters are still safe and effective treatment alternatives for management of upper ureteral stones. (author)

  6. Radiation damage assessment of Nb tunnel junction devices

    International Nuclear Information System (INIS)

    King, S.E.; Magno, R.; Maisch, W.G.

    1991-01-01

    This paper reports on the radiation hardness of a new technology using Josephson junctions that was explored by an irradiation using a fluence of 7.6 x 10 14 protons/cm 2 at an energy of 63 MeV from the U.C. Davis cyclotron. In what the authors believe is the first radiation assessment of Nb/Al 2 O 3 /Nb devices, the permanent damage in these devices was investigated. No permanent changes in the I-V characteristics of the junctions were observed indicating no significant level of material defects have occurred at this level of irradiation

  7. Optical vector network analysis of ultranarrow transitions in 166Er3+ : 7LiYF4 crystal.

    Science.gov (United States)

    Kukharchyk, N; Sholokhov, D; Morozov, O; Korableva, S L; Cole, J H; Kalachev, A A; Bushev, P A

    2018-02-15

    We present optical vector network analysis (OVNA) of an isotopically purified Er166 3+ :LiYF 4 7 crystal. The OVNA method is based on generation and detection of a modulated optical sideband by using a radio-frequency vector network analyzer. This technique is widely used in the field of microwave photonics for the characterization of optical responses of optical devices such as filters and high-Q resonators. However, dense solid-state atomic ensembles induce a large phase shift on one of the optical sidebands that results in the appearance of extra features on the measured transmission response. We present a simple theoretical model that accurately describes the observed spectra and helps to reconstruct the absorption profile of a solid-state atomic ensemble as well as corresponding change of the refractive index in the vicinity of atomic resonances.

  8. Method of manufacturing semiconductor devices

    International Nuclear Information System (INIS)

    Sun, Y.S.E.

    1980-01-01

    A method of improving the electrical characteristics of semiconductor devices such as SCR's, rectifiers and triacs during their manufacture is described. The system consists of electron irradiation at an energy in excess of 250 KeV and most preferably between 1.5 and 12 MeV, producing an irradiation dose of between 5.10 12 and 5.10 15 electrons per sq. cm., and at a temperature in excess of 100 0 C preferably between 150 and 375 0 C. (U.K.)

  9. Development of the external cooling device of increase the productivity of neutron-transmutation-doped silicon semiconductor (NTD-Si) (Joint research)

    International Nuclear Information System (INIS)

    Hirose, Akira; Wada, Shigeru; Sasajima, Fumio; Kusunoki, Tsuyoshi; Kameyama, Iwao; Aizawa, Ryouji; Kikuchi, Naoyuki

    2007-01-01

    Neutron-Transmutation-Doped Silicon Semiconductor (hereinafter referred as 'NTD-Si') is the best semiconductor for the power device. The needs of NTD-Si increase recently in proportion to the popularization of hybrid-cars. A fission research reactor, which is a steady state neutron source, is being expected as the best device to meet the needs. So far, we have reconsidered the existing approach which is employed for NTD-Si production works at the research reactors JRR-3, JRR-4 and JMTR of JAEA so as to meet the needs. As one of the effective measures, we found out that the productivity can be increased by incorporating a new device to cool down radioactivity of irradiated silicon ingots at the place outside the main stream from the loading of silicon ingots to the withdrawal of irradiated ingots to the existing JRR-3 Uniformity Irradiation System. Consequently, we developed and installed the device (hereinafter referred as 'external cooling device'). After an ingot was irradiated once, it is turned over manually and irradiated again in order to irradiate the ingot uniformly. With the conventional system, it was necessary to wait the radioactivity of ingot decrease less than the permissible level with holding the ingot in the irradiation equipment. It was effective to shorten the waiting period by using an external cooling device for production increase of NTD-Si. It is expected that the productivity of NTD-Si will be increased by using the external cooling device. This report mentions the design of the external cooling device and verification between its design specifications and the performance of the device completed. (author)

  10. Electrical effects of transient neutron irradiation of silicon devices

    International Nuclear Information System (INIS)

    Hjalmarson, H.P.; Pease, R.L.; Van Ginhoven, R.M.; Schultz, P.A.; Modine, N.A.

    2007-01-01

    The key effects of combined transient neutron and ionizing radiation on silicon diodes and bipolar junctions transistors are described. The results show that interstitial defect reactions dominate the annealing effects in the first stage of annealing for certain devices. Furthermore, the results show that oxide trapped charge can influence the effects of bulk silicon displacement damage for particular devices

  11. Ceramic and polymeric devices for breast brachytherapy - Mammographic and CT response

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Campos, Tarcisio P.R.

    2009-01-01

    The present research investigates the radiological visibility of ceramic and polymeric devices implanted in breast phantom (in vitro) for future applications in brachytherapy treatments. The main research goal is to investigate the viability of monitoring ceramic and polymeric devices, in vitro based on simple methods of radiological diagnostic, maintaining the easiest access to the population, represented by the conventional X-ray and mammography. The methodology involves the processing of ceramic devices constituted by bioglasses of Sm, SmBa, Ho, HoBa and the production of polymeric devices, such as polymeric membranes incorporating Ho e HoBa. Contrast agent of Barium was introduced in the syntheses of those devices to improve the radiological visibility in breast equivalent-tissue (TE) phantom. The breast phantom is constituted of glandular, adipose and skin TE, reproducing a 5 cm compressed real breast. In the compressed breast phantom, all types of ceramic and polymeric devices were implanted side by side. Radiological images were generated through X-ray equipment, mammography and computerized tomography (TC), for the samples implanted in the compressed breast phantom. The results show that SmBa and HoBa seeds on breast phantom presented suitable radiological visibility, on all the radiological diagnostic methods. However, the X-rays radiological visibility of Sm seeds without contrast was discreet. On mammography and TC images, it was not possible to identify those seeds, because the same ones were degraded after two months immersed in the glandular TE, after placed on the phantom. The Ho seeds were identified on all radiological diagnostic images, although non contrast agent in its constitution was added. However, the holmium polymeric membranes in direct contact with TE did not show Xray radiological visibility. However, the polymeric membranes of HoBa in the same conditions presented efficient X-rays radiological response. For mammography and TC methods

  12. Performance and safety of holmium: YAG laser optical fibers.

    Science.gov (United States)

    Knudsen, Bodo E; Glickman, Randolph D; Stallman, Kenneth J; Maswadi, Saher; Chew, Ben H; Beiko, Darren T; Denstedt, John D; Teichman, Joel M H

    2005-11-01

    Lower-pole ureteronephroscopy requires transmission of holmium:YAG energy along a deflected fiber. Current ureteroscopes are capable of high degrees of deflection, which may stress laser fibers beyond safe limits during lower-pole use. We hypothesized that optical fiber and safety measures differ among manufacturers. Small (200-273-microm) and medium-diameter (300-400-microm) Ho:YAG fibers were tested in a straight and 180 degrees bent configuration. Energy transmission was measured by an energy detector. Fiber durability was assessed by firing the laser in sequentially tighter bending diameters. The fibers were bent to 180 degrees with a diameter of 6 cm and run at 200- to 4000-mJ pulse energy to determine the minimum energy required to fracture the fiber. The bending diameter was decreased by 1-cm increments and testing repeated until a bending diameter of 1 cm was reached. The maximum deflection of the ACMI DUR-8E ureteroscope with each fiber in the working channel was recorded. The flow rate through the working channel of the DUR-8E was measured for each fiber. The mean energy transmission differed among fibers (P < 0.001). The Lumenis SL 200 and the InnovaQuartz 400 were the best small and medium-diameter fibers, respectively, in resisting thermal breakdown (P < 0.01). The Dornier Lightguide Super 200 fractured repeatedly at a bend diameter of 2 cm and with the lowest energy (200 mJ). The other small fibers fractured only at a bend diameter of 1 cm. The Sharplan 200 and InnovaQuartz Sureflex 273T were the most flexible fibers, the Lumenis SL 365 the least. The flow rate was inversely proportional to four times the power of the diameter of the fiber. Optical performance and safety differ among fibers. Fibers transmit various amounts of energy to their cladding when bent. During lower-pole nephroscopy with the fiber deflected, there is a risk of fiber fracture from thermal breakdown and laser-energy transmission to the endoscope. Some available laser fibers

  13. Ultrafine tungsten as a plasma-facing component in fusion devices: effect of high flux, high fluence low energy helium irradiation

    International Nuclear Information System (INIS)

    El-Atwani, O.; Gonderman, Sean; Allain, J.P.; Efe, Mert; Klenosky, Daniel; Qiu, Tian; De Temmerman, Gregory; Morgan, Thomas; Bystrov, Kirill

    2014-01-01

    This work discusses the response of ultrafine-grained tungsten materials to high-flux, high-fluence, low energy pure He irradiation. Ultrafine-grained tungsten samples were exposed in the Pilot-PSI (Westerhout et al 2007 Phys. Scr. T128 18) linear plasma device at the Dutch Institute for Fundamental Energy Research (DIFFER) in Nieuwegein, the Netherlands. The He flux on the tungsten samples ranged from 1.0 × 10 23 –2.0 × 10 24  ions m −2  s −1 , the sample bias ranged from a negative (20–65) V, and the sample temperatures ranged from 600–1500 °C. SEM analysis of the exposed samples clearly shows that ultrafine-grained tungsten materials have a greater fluence threshold to the formation of fuzz by an order or magnitude or more, supporting the conjecture that grain boundaries play a major role in the mechanisms of radiation damage. Pre-fuzz damage analysis is addressed, as in the role of grain orientation on structure formation. Grains of (1 1 0) and (1 1 1) orientation showed only pore formation, while (0 0 1) oriented grains showed ripples (higher structures) decorated with pores. Blistering at the grain boundaries is also observed in this case. In situ TEM analysis during irradiation revealed facetted bubble formation at the grain boundaries likely responsible for blistering at this location. The results could have significant implications for future plasma-burning fusion devices given the He-induced damage could lead to macroscopic dust emission into the fusion plasma. (paper)

  14. Transportation of 33 irradiated MTR fuel assemblies from FRM/Garching to Savannah River Site, USA, using a GNS transport cask and using a new loading device

    International Nuclear Information System (INIS)

    Dreesen, K.; Goetze, H.G.; Holst, L.; Gerstenberg, H.; Schreckenbach, K.

    2000-01-01

    According to the Department of Energy program of the return spent fuel from the foreign research reactors operators, 33 irradiated MTR box shaped fuel assemblies from the Technical University Munich were shipped to SRS/USA. The fuel assemblies were irradiated for typically 800 full days and, after a sufficient cooling time, loaded into a GNS 16 cask. The GNS 16 cask is a new transport cask for box shaped MTR fuel assemblies and TRIGA fuel assemblies and was used for the first time at the FRM Garching. The capacity of the cask is 33 box shaped MTR fuel assemblies. During the loading of the fuel assemblies, a newly developed loading device was used. The main components of the loading device are the transfer flask, the shielded loading lock, adapter plate and a mobile water tank. The loading device works mechanically with manpower. For the handling of the transfer flask, a crane with a capacity of 5 metric tons is necessary. During installation of the lid the mobile water pool is filled with demineralized water and the shielded loading passage is taken away. After that the lid is put on the cask. After drainage, the mobile water pool is disassembled, and the cask is dewatered. Finally leak tests of all seals are made. The achieved leakage rate was -5 Pa x I/s. The work in FRM was done between 03.02.99 and 12.02.99 including a dry run and leak test. (author)

  15. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  16. Multi-physic simulations of irradiation experiments in a technological irradiation reactor; Modelisation pluridisciplinaire d'experiences d'irradiation dans un reacteur d'irradiation technologique

    Energy Technology Data Exchange (ETDEWEB)

    Bonaccorsi, Th

    2007-09-15

    A Material Testing Reactor (MTR) makes it possible to irradiate material samples under intense neutron and photonic fluxes. These experiments are carried out in experimental devices localised in the reactor core or in periphery (reflector). Available physics simulation tools only treat, most of the time, one physics field in a very precise way. Multi-physic simulations of irradiation experiments therefore require a sequential use of several calculation codes and data exchanges between these codes: this corresponds to problems coupling. In order to facilitate multi-physic simulations, this thesis sets up a data model based on data-processing objects, called Technological Entities. This data model is common to all of the physics fields. It permits defining the geometry of an irradiation device in a parametric way and to associate information about materials to it. Numerical simulations are encapsulated into interfaces providing the ability to call specific functionalities with the same command (to initialize data, to launch calculations, to post-treat, to get results,... ). Thus, once encapsulated, numerical simulations can be re-used for various studies. This data model is developed in a SALOME platform component. The first application case made it possible to perform neutronic simulations (OSIRIS reactor and RJH) coupled with fuel behavior simulations. In a next step, thermal hydraulics could also be taken into account. In addition to the improvement of the calculation accuracy due to the physical phenomena coupling, the time spent in the development phase of the simulation is largely reduced and the possibilities of uncertainty treatment are under consideration. (author)

  17. Simulation of gamma-ray irradiation of lettuce leaves in a 137Cs irradiator using MCNP

    International Nuclear Information System (INIS)

    Kim, Jongsoon; Moreira, Rosana G.; Braby, Leslie A.

    2010-01-01

    Ionizing radiation effectively reduces the number of common microbial pathogens in fresh produce. However, the efficacy of the process for pathogens internalized into produce tissue is unknown. The objective of this study was to understand gamma irradiation of lettuce leaf structure exposed in a 137 Cs irradiator using MCNP. The simulated 137 Cs irradiator is a self-shielded device, and its geometry and sources are described in the MCNP input file. When the irradiation chamber is filled with water, lower doses are found at the center of the irradiation volume and the dose uniformity ratio (maximum dose/minimum dose) is 1.76. For randomly oriented rectangular lettuce leaf segments in the irradiation chamber, the dose uniformity ratio is 1.25. It shows that dose uniformity in the Cs irradiator is strongly dependent of the density of the sample. To understand dose distribution inside the leaf, we divided a lettuce leaf into a low density (flat) region (0.72 g/cm 3 ) and high density (rib) region (0.86 g/cm 3 ). Calculated doses to the rib are 61% higher than doses to the flat region of the leaf. This indicates that internalized microorganisms can be inactivated more easily than organisms on the surface. This study shows that irradiation can effectively reduce viable microorganism internalized in lettuce. (author)

  18. Test Standard Revision Update: JESD57, "Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation"

    Science.gov (United States)

    Lauenstein, Jean-Marie

    2015-01-01

    The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.

  19. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Habte, A.; Andreas, A.; Ottoson, L.; Gueymard, C.; Fedor, G.; Fowler, S.; Peterson, J.; Naranen, E.; Kobashi, T.; Akiyama, A.; Takagi, S.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements of the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.

  20. Gamma irradiator dose mapping: a Monte Carlo simulation and experimental measurements

    International Nuclear Information System (INIS)

    Rodrigues, Rogerio R.; Ribeiro, Mariana A.; Grynberg, Suely E.; Ferreira, Andrea V.; Meira-Belo, Luiz Claudio; Sousa, Romulo V.; Sebastiao, Rita de C.O.

    2009-01-01

    Gamma irradiator facilities can be used in a wide range of applications such as biological and chemical researches, food treatment and sterilization of medical devices and products. Dose mapping must be performed in these equipment in order to establish plant operational parameters, as dose uniformity, source utilization efficiency and maximum and minimum dose positions. The isodoses curves are generally measured using dosimeters distributed throughout the device, and this procedure often consume a large amount of dosimeters, irradiation time and manpower. However, a detailed curve doses identification of the irradiation facility can be performed using Monte Carlo simulation, which reduces significantly the monitoring with dosimeters. The present work evaluates the absorbed dose in the CDTN/CNEN Gammacell Irradiation Facility, using the Monte Carlo N-particles (MCNP) code. The Gammacell 220, serial number 39, was produced by Atomic Energy of Canada Limited and was loaded with sources of 60 Co. Dose measurements using TLD and Fricke dosimeters were also performed to validate the calculations. The good agreement of the results shows that Monte Carlo simulations can be used as a predictive tool of irradiation planning for the CDTN/CNEN Gamma Cell Irradiator. (author)

  1. Single Event Gate Rupture in 130-nm CMOS Transistor Arrays Subjected to X-Ray Irradiation

    CERN Document Server

    Silvestri, M; Gerardin, Simone; Faccio, Federico; Paccagnella, Alessandro

    2010-01-01

    We present new experimental results on heavy ion-induced gate rupture on deep submicron CMOS transistor arrays. Through the use of dedicated test structures, composed by a large number of 130-nm MOSFETs connected in parallel, we show the response to heavy ion irradiation under high stress voltages of devices previously irradiated with X-rays. We found only a slight impact on gate rupture critical voltage at a LET of 32 MeV cm(2) mg(-1) for devices previously irradiated up to 3 Mrad(SiO2), and practically no change for 100 Mrad(SiO2) irradiation, dose of interest for the future super large hadron collider (SLHC).

  2. Monte Carlo simulation of irradiation of MTR fuel plates in the BR2 reactor using a full-scale 3-d model with inclined channels

    International Nuclear Information System (INIS)

    Kuzminov, V. V; Koonen, E.; Ponsard, B.

    2002-01-01

    A three-dimensional full-scale Monte Carlo model of the BR2 reactor has been developed for simulation of irradiation conditions of materials and fuel loaded in various irradiation devices. This new reactor model includes a detailed geometrical description of the inclined reactor channels, the irradiation devices loaded in these channels including the materials to be tested/loaded in these devices, the burn-up of the BR2 fuel elements and the poisoning of the beryllium matrix. Recently a benchmark irradiation of new irradiation device for testing and qualification of MTR fuel plates has been performed. For this purpose the detailed irradiation conditions of fuel plates had to be predetermined. Monte Carlo calculations of neutron fluxes and heat load distributions in irradiated MTR fuel plates were performed taking into account the contents of all loaded experimental devices in the reactor channels. A comparison of the calculated and measured values of neutron fluxes and of heat loads in the BR2 reactor is presented in this paper. The comparison is part of the validation process of the new reactor model. It also serves to establish the capability to conduct a fuel plate irradiation program under requested and well- known irradiation conditions. (author)

  3. Electrical Characterization of Irradiated Semiconducting Amorphous Hydrogenated Boron Carbide

    Science.gov (United States)

    Peterson, George Glenn

    Semiconducting amorphous partially dehydrogenated boron carbide has been explored as a neutron voltaic for operation in radiation harsh environments, such as on deep space satellites/probes. A neutron voltaic device could also be used as a solid state neutron radiation detector to provide immediate alerts for radiation workers/students, as opposed to the passive dosimetry badges utilized today. Understanding how the irradiation environment effects the electrical properties of semiconducting amorphous partially dehydrogenated boron carbide is important to predicting the stability of these devices in operation. p-n heterojunction diodes were formed from the synthesis of semiconducting amorphous partially dehydrogenated boron carbide on silicon substrates through the use of plasma enhanced chemical vapor deposition (PECVD). Many forms of structural and electrical measurements and analysis have been performed on the p-n heterojunction devices as a function of both He+ ion and neutron irradiation including: transmission electron microscopy (TEM), selected area electron diffraction (SAED), current versus voltage I(V), capacitance versus voltage C(V), conductance versus frequency G(f), and charge carrier lifetime (tau). In stark contrast to nearly all other electronic devices, the electrical performance of these p-n heterojunction diodes improved with irradiation. This is most likely the result of bond defect passivation and resolution of degraded icosahedral based carborane structures (icosahedral molecules missing a B, C, or H atom(s)).

  4. 78 FR 24235 - 166th Meeting of the Advisory Council on Employee Welfare and Pension Benefit Plans; Notice of...

    Science.gov (United States)

    2013-04-24

    ... DEPARTMENT OF LABOR Employee Benefits Security Administration 166th Meeting of the Advisory Council on Employee Welfare and Pension Benefit Plans; Notice of Meeting Pursuant to the authority... 166th open meeting of the Advisory Council on Employee Welfare and Pension Benefit Plans (also known as...

  5. Silicon/HfO2 interface: Effects of proton irradiation

    International Nuclear Information System (INIS)

    Maurya, Savita; Radhakrishna, M.

    2015-01-01

    Substrate oxide interfaces are of paramount importance in deciding the quality of the semiconductor devices. In this work we have studied how 200 keV proton irradiation affects the interface of a 13 nm thick, atomic layer deposited hafnium dioxide on silicon substrate. Pre- and post-irradiation electrical measurements are used to quantify the effect of proton irradiation for varying electrode geometries. Proton irradiation introduces positive charge in the oxide and at the interface of Si/HfO 2 interface. The gate current is not very much affected under positive injection since the induced positive charge is compensated by the injected electrons. Current voltage characteristics under negative bias get affected by the proton irradiation

  6. PKI 166 induced redox signalling and apoptosis through activation of p53, MAP kinase and caspase pathway in epidermoid carcinoma.

    Science.gov (United States)

    Das, Subhasis; Dey, Kaushik Kumar; Bharti, Rashmi; MaitiChoudhury, Sujata; Maiti, Sukumar; Mandal, Mahitosh

    2012-01-01

    Cellular redox changes have emerged as a pivotal and proximal event in cancer. PKI 166 is used to determine the effects of redox sensitive inhibition of EGFR, metastasis and apoptosis in epidermoid carcinoma. Cytotoxicity study of PKI 166 (IC50 1.0 microM) treated A431 cells were performed by MTT assay for 48 and 72 hrs. Morphological analysis of PKI 166 treated A431 cells for 48 hrs. revealed the cell shrinkage, loss of filopodia and lamellipodia by phase contrast and SEM images in dose dependent manner. It has cytotoxic effects through inhibiting cellular proliferation, leads to the induction of apoptosis, as increased fraction of sub-G1 phase of the cell cycle, chromatin condensation and DNA ladder. It inhibited cyclin-D1 and cyclin-E expression and induced p53, p21 expression in dose dependent manner. Consequently, an imbalance of Bax/Bcl-2 ratio triggered caspase cascade and subsequent cleavage of PARP, thereby shifting the balance in favour of apoptosis. PKI 166 treatment actively stimulated reactive oxygen species (ROS) and mitochondrial membrane depolarization. It inhibited some metastatic properties of A431 cells supressing colony formation by soft agar assay and inhibition of MMP 9 activity by gelatin zymography and western blot analysis. PKI 166 inhibited growth factor induced phosphorylation of EGFR, Akt, MAPK, JNK and colony formation in A431 cells. Thus the inhibition of proliferation was associated with redox regulation of the caspase cascade, EGFR, Akt/PI3K, MAPK/ ERK and JNK pathway. On the other hand, increased antioxidant activity leads to decreased ROS generation inhibit the anti-proliferative and apoptotic properties of PKI 166 in A431 cells. These observations indicated PKI 166 induced redox signalling dependent inhibition of cell proliferation, metastatic properties and induction of apoptotic potential in epidermoid carcinoma.

  7. 25 CFR 166.903 - How can I get an agriculture scholarship?

    Science.gov (United States)

    2010-04-01

    ... scholarships must reapply annually to continue to receive funding beyond the initial award period. Students who... degree-granting program at an accredited college or university. (g) Graduate scholarships are available... 25 Indians 1 2010-04-01 2010-04-01 false How can I get an agriculture scholarship? 166.903 Section...

  8. Studies on the production and application of radioisotopes -Studies on application of radiation and radioisotopes-

    International Nuclear Information System (INIS)

    Kim, Jae Rok; Park, Kyung Bae; Chung, Yong Sam; Chung, Young Ju; Bang, Hong Sik; Han, Hyun Soo; Shin, Byung Chul; Park, Choon Deuk; Han, Kwang Hee; Shin, Hun Young; Park, Woong Woo; Kim, Dong Soo; Kim, Jin Kyung; Kim, Seung Jun

    1994-07-01

    To increase the production of RI and labelled compounds utilizing the Korea Multipurpose Research Reactor (KMRR), development of P-32 production process, devices and tools of neutron irradiation use, GMP facilities of radiopharmaceuticals, Dy-165/Ho-166 macroaggregate of radiation synovectomy use for rheumatoid archritis have been carried out, respectively. To utilize NAA in analysis of environmental samples, experimental studies on air borne samples have also been carried out. An efficient P-32 production process obtaining high recovery of >98% with sufficiently high radionuclidic purity of >99% has been established through reaction 32 S(n,p) 32 P and subsequent reduced pressure distillation purification. Various capsules, loading/unloading device for capsule/rigs, cole-welder for capsules, checking instrument for capsule sealing, working table/tools, transfer cask for the irradiated targets, etc. have been developed. To maintain cleanliness inside of hot cells, a modification has been proposed, and a two door type autoclave usable in GMP facility has been prepared. An efficient way of preparation of the Dy-165/Ho-166 macroaggregate of radiation synovectomy use as well as its clinical application scheme has been developed. A suitable process of environmental sample analyses has been established by carrying out NAA of standard/reference samples as well as airborne dust samples. (Author)

  9. Electric field and temperature effects in irradiated MOSFETs

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, M. A. G., E-mail: marcilei@fei.edu.br; Santos, R. B. B.; Leite, F. G.; Araújo, N. E.; Cirne, K. H.; Melo, M. A. A.; Rallo, A. [Centro Universitário da FEI, São Bernardo do Campo, S.P. (Brazil); Aguiar, Vitor A. P.; Aguirre, F.; Macchione, E. L. A.; Added, N.; Medina, N. H. [Instituto de Física da USP, São Paulo, S.P. (Brazil)

    2016-07-07

    Electronic devices exposed to ionizing radiation exhibit degradation on their electrical characteristics, which may compromise the functionality of the device. Understanding the physical phenomena responsible for radiation damage, which may be specific to a particular technology, it is of extreme importance to develop methods for testing and recovering the devices. The aim of this work is to check the influence of thermal annealing processes and electric field applied during irradiation of Metal Oxide Semiconductor Field Effect Transistors (MOSFET) in total ionizing dose experiments analyzing the changes in the electrical parameters in these devices.

  10. Irradiation and annealing of p-type silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, Alexander A.; Bogdanova, Elena V.; Grigor' eva, Maria V.; Lebedev, Sergey P. [A.F. Ioffe Physical-Technical Institute, St. Petersburg, 194021 (Russian Federation); Kozlovski, Vitaly V. [St. Petersburg State Polytechnic University, St. Petersburg, 195251 (Russian Federation)

    2014-02-21

    The development of the technology of semiconductor devices based on silicon carbide and the beginning of their industrial manufacture have made increasingly topical studies of the radiation hardness of this material on the one hand and of the proton irradiation to form high-receptivity regions on the other hand. This paper reports on a study of the carrier removal rate (V{sub d}) in p-6H-SiC under irradiation with 8 MeV protons and of the conductivity restoration in radiation- compensated epitaxial layers of various p-type silicon carbide polytypes. V{sub d} was determined by analysis of capacitance-voltage characteristics and from results of Hall effect measurements. It was found that the complete compensation of samples with the initial value of Na - Nd ≈ 1.5 × 10{sup 18} cm{sup −3} occurs at an irradiation dose of ∼1.1 × 10{sup 16} cm{sup −2}. It is shown that specific features of the sublimation layer SiC (compared to CVD layers) are clearly manifested upon the gamma and electron irradiation and are hardly noticeable under the proton and neutron irradiation. It was also found that the radiation-induced compensation of SiC is retained after its annealing at ≤1000°C. The conductivity is almost completely restored at T ≥ 1200°C. This character of annealing of the radiation compensation is independent of a silicon carbide polytype and the starting doping level of the epitaxial layer. The complete annealing temperatures considerably exceed the working temperatures of SiC-based devices. It is shown that the radiation compensation is a promising method in the technology of high-temperature devices based on SiC.

  11. Multi-physic simulations of irradiation experiments in a technological irradiation reactor

    International Nuclear Information System (INIS)

    Bonaccorsi, Th.

    2007-09-01

    A Material Testing Reactor (MTR) makes it possible to irradiate material samples under intense neutron and photonic fluxes. These experiments are carried out in experimental devices localised in the reactor core or in periphery (reflector). Available physics simulation tools only treat, most of the time, one physics field in a very precise way. Multi-physic simulations of irradiation experiments therefore require a sequential use of several calculation codes and data exchanges between these codes: this corresponds to problems coupling. In order to facilitate multi-physic simulations, this thesis sets up a data model based on data-processing objects, called Technological Entities. This data model is common to all of the physics fields. It permits defining the geometry of an irradiation device in a parametric way and to associate information about materials to it. Numerical simulations are encapsulated into interfaces providing the ability to call specific functionalities with the same command (to initialize data, to launch calculations, to post-treat, to get results,... ). Thus, once encapsulated, numerical simulations can be re-used for various studies. This data model is developed in a SALOME platform component. The first application case made it possible to perform neutronic simulations (OSIRIS reactor and RJH) coupled with fuel behavior simulations. In a next step, thermal hydraulics could also be taken into account. In addition to the improvement of the calculation accuracy due to the physical phenomena coupling, the time spent in the development phase of the simulation is largely reduced and the possibilities of uncertainty treatment are under consideration. (author)

  12. High Total Ionizing Dose and Temperature Effects on Micro- and Nano-electronic Devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Martinez, M.; Paillet, P.; Leray, J.L.; Marcandella, C.; Duhamel, O.; Raine, M.; Richard, N.; Girard, S.; Ouerdane, Y.; Boukenter, A.; Goiffon, V.; Magnan, P.; Andrieu, F.; Barraud, S.; Faynot, O.

    2013-06-01

    This paper investigates the vulnerability of several micro- and nano-electronic technologies to a mixed harsh environment including high total ionizing dose at MGy levels and high temperature. Such operating conditions have been revealed recently for several applications like new security systems in existing or future nuclear power plants, fusion experiments, or deep space missions. In this work, the competing effects already reported in literature of ionizing radiations and temperature are characterized in elementary devices made of MOS transistors from several technologies. First, devices are irradiated using a radiation laboratory X-ray source up to MGy dose levels at room temperature. Devices are grounded during irradiation to simulate a circuit which waits for a wake up signal, representing most of the lifetime of an integrated circuit operating in a harsh environment. Devices are then annealed at several temperatures to discuss the post-irradiation behavior and to determine whether an elevated temperature is an issue or not for circuit function in mixed harsh environments. (authors)

  13. An integrated fiber and stone basket device for use in Thulium fiber laser lithotripsy

    Science.gov (United States)

    Wilson, Christopher R.; Hutchens, Thomas C.; Hardy, Luke A.; Irby, Pierce B.; Fried, Nathaniel M.

    2014-03-01

    The Thulium fiber laser (TFL) is being explored as an alternative laser lithotripter to the Holmium:YAG laser. The TFL's superior near-single mode beam profile enables higher power transmission through smaller fibers with reduced proximal fiber tip damage. Recent studies have also reported that attaching hollow steel tubing to the distal fiber tip decreases fiber degradation and burn-back without compromising stone ablation rates. However, significant stone retropulsion was observed, which increased with pulse rate. In this study, the hollow steel tip fiber design was integrated with a stone basket to minimize stone retropulsion during ablation. A device was constructed consisting of a 100-μm-core, 140-μm-OD silica fiber outfitted with 5-mm-long stainless steel tubing at the distal tip, and integrated with a 1.3-Fr (0.433-mm-OD) disposable nitinol wire basket, to form an overall 1.9-Fr (0.633-mm- OD) integrated device. This compact design may provide several potential advantages including increased flexibility, higher saline irrigation rates through the ureteroscope working channel, and reduced fiber tip degradation compared to separate fiber and stone basket manipulation. TFL pulse energy of 31.5 mJ with 500 μs pulse duration and pulse rate of 500 Hz was delivered through the integrated fiber/basket device in contact with human uric acid stones, ex vivo. TFL stone ablation rates measured 1.5 +/- 0.2 mg/s, comparable to 1.7 +/- 0.3 mg/s (P > 0.05) using standard bare fiber tips separately with a stone basket. With further development, this device may be useful for minimizing stone retropulsion, thus enabling more efficient TFL lithotripsy at higher pulse rates.

  14. Augmented growth inhibition of B16-BL6 melanoma by combined treatment with a selective matrix metalloproteinase inhibitor, MMI-166, and cytotoxic agents.

    Science.gov (United States)

    Hojo, Kanji; Maki, Hideo; Sawada, Takuko Yamada; Maekawa, Ryuji; Yoshioka, Takayuki

    2002-01-01

    MMI-166 is a selective matrix metalloproteinase (MMP) inhibitor. The purpose of this study was to evaluate the antitumor efficacy of the combined treatment of MMI-166 with paclitaxel or carboplatin. Mice bearing B16-BL6 melanoma were treated p.o. with MMI-166 from 1 day after tumor inoculation. The mice were administered i.v. with either paclitaxel or carboplatin at the maximum tolerated dose (MTD). MMI-166 monotherapy inhibited in vivo growth of the B16-BL6 tumor to an extent similar to that of paclitaxel or carboplatin monotherapy. When MMI-166 was combined with paclitaxel or carboplatin, the antitumor efficacy was significantly (p B16-BL6 tumor cells nor does it augment the cytotoxicity of paclitaxel or carboplatin. These results indicate that augmented antitumor activity of the combination treatment was not simply due to the augmentation of direct cytotoxic activity, but was rather an additive effect of the antitumor activities of different mechanisms. They suggest the effectiveness of a combination therapy of MMI-166 with paclitaxel or carboplatin in clinical therapy.

  15. Neutronic Modelling in Support of the Irradiation Programmes

    International Nuclear Information System (INIS)

    Koonen, E.

    2005-01-01

    Irradiation experiments are generally conducted to determine some specific characteristics of the concerned fuels and structural materials under well defined irradiation conditions. For the determination of the latter the BR2 division has an autonomous reactor physics cell and has implemented the required computational tools. The major tool used is a three-dimensional full-scale Monte Carlo model of the BR2 reactor developed under MCNP-4C for the simulation of irradiation conditions. The objectives of work performed by SCK-CEN are to evaluate and adjust irradiation conditions by adjustments of the environment, differential rod positions, axial and azimuthal positioning of the samples, global power level, ...; to deliver reliable, well defined irradiation condition and fluence data during and after irradiation; to assist the designer of new irradiation devices by simulations and neutronic optimisations of design options; to provide computational support to related projects as a way to valorise the capabilities that the BR2 reactor can offer

  16. Relationship between measurements of blood oxidative metabolites and skin reaction in irradiated rats

    International Nuclear Information System (INIS)

    Kaneko, Takashi; Goto, Jun; Nomiya, Takuma; Nemoto, Kenji

    2011-01-01

    Recently, oxidative metabolites have been able to be measured by simple small device. It has been reported that the value of oxidative metabolites increases under several conditions such as hypertension, smoking, diabetes mellitus, etc. Radiation used in radiotherapy also causes free radicals and oxidative metabolites, and irradiation causes dermatitis and sometimes causes skin ulcer in the irradiated site. We analyzed the relationships between the value of oxidative metabolites and skin reactions. A certain doses of radiation were irradiated to the right thigh of rats, and oxidative metabolites of rat's blood from caudal vein were measured by d-reactive oxygen metabolites (ROMs) test using an exclusive device. Skin reactions were evaluated according to a skin-reaction grading system from the day before irradiation to day 38 after irradiation. As a results, a significant correlation was shown between irradiation dose and skin grade. And a significant correlation was also shown between the value of oxidative metabolites and irradiation dose. The increase in oxidative metabolites was seen in the Day 16 after irradiation, and that corresponded with the appearance of skin reaction. It was suggested that the value of oxidative metabolites seems to be useful for estimating degree of skin reaction and time to appear skin reaction after irradiation. (author)

  17. Comparison of Ho and Y complexation data obtained by electromigration methods, potentiometry and spectrophotometry

    International Nuclear Information System (INIS)

    Vinsova, H.; Koudelkova, M.; Ernestova, M.; Jedinakova-Krizova, V.

    2003-01-01

    Many of holmium and yttrium complex compounds of both organic and inorganic origin have been studied recently from the point of view of their radiopharmaceutical behavior. Complexes with Ho-166 and Y-90 can be either directly used as pharmaceutical preparations or they can be applied in a conjugate form with selected monoclonal antibody. Appropriate bifunctional chelation agents are necessary in the latter case for indirect binding of monoclonal antibody and selected radionuclide. Our present study has been focused on the characterization of radionuclide (metal) - ligand interaction using various analytical methods. Electromigration methods (capillary electrophoresis, capillary isotachophoresis), potentiometric titration and spectrophotometry have been tested from the point of view of their potential to determine conditional stability constants of holmium and yttrium complexes. A principle of an isotachophoretic determination of stability constants is based on the linear relation between logarithms of stability constant and a reduction of a zone of complex. For the calculation of thermodynamic constants using potentiometry it was necessary at first to determine the protonation constants of acid. Those were calculated using the computer program LETAGROP Etitr from data obtained by potentiometric acid-base titration. Consequently, the titration curves of holmium and yttrium with studied ligands and protonation constants of corresponding acid were applied for the calculation of metal-ligand stability constants. Spectrophotometric determination of stability constants of selected systems was based on the titration of holmium and yttrium nitrate solutions by Arsenazo III following by the titration of metal-Arsenazo III complex by selected ligand. Data obtained have been evaluated using the computation program OPIUM. Results obtained by all analytical methods tested in this study have been compared. It was found that direct potentiometric titration technique could not be

  18. A bromine-based dichroic X-ray polarization analyser

    CERN Document Server

    Collins, S P; Brown, S D; Thompson, P

    2001-01-01

    We have demonstrated the advantages offered by dichroic X-ray polarization filters for linear polarization analysis, and describe such a device, based on a dibromoalkane/urea inclusion compound. The polarizer has been successfully tested by analysing the polarization of magnetic diffraction from holmium.

  19. Irradiation of optically activated SI-GaAs high-voltage switches with low and high energy protons

    CERN Document Server

    Bertolucci, Ennio; Mettivier, G; Russo, P; Bisogni, M G; Bottigli, U; Fantacci, M E; Stefanini, A; Cola, A; Quaranta, F; Vasanelli, L; Stefanini, G

    1999-01-01

    Semi-Insulating Gallium Arsenide (SI-GaAs) devices have been tested for radiation hardness with 3-4 MeV or 24 GeV proton beams. These devices can be operated in dc mode as optically activated electrical switches up to 1 kV. Both single switches (vertical Schottky diodes) and multiple (8) switches (planar devices) have been studied, by analyzing their current-voltage (I-V) reverse characteristics in the dark and under red light illumination, both before and after irradiation. We propose to use them in the system of high-voltage (-600 V) switches for the microstrip gas chambers for the CMS experiment at CERN. Low energy protons (3-4 MeV) were used in order to produce a surface damage below the Schottky contact: their fluence (up to 2.6*10/sup 15/ p/cm/sup 2/) gives a high-dose irradiation. The high energy proton irradiation (energy: 24 GeV, fluence: 1.1*10/sup 14/ p/cm/sup 2/) reproduced a ten years long proton exposure of the devices in CMS experiment conditions. For low energy irradiation, limited changes of ...

  20. Bone marrow ablation with Ho-166 pharmaceuticals as preparation for bone marrow transplants

    International Nuclear Information System (INIS)

    Parks, N.J.; Kawakami, T.; Avila, M.; White, R.; Cain, G.; Moore, P.F.

    1991-01-01

    Bone marrow ablation is required preparation for leukemia patients where bone marrow transplantation is to be the therapeutic modality. Presently, the total body irradiation that is used produces appreciable morbidity in terms of radiation sickness, but an evenly distributed dose to marrow. The authors have shown in Beagles that bone-seeking radiolanthanide (Ho-166, t 1/2 = 25 h, 1.8 MeB beta, carrier added) phosphonic acid chelates can be used to completely ablate bone marrow with little morbidity. The research plan, incorporating bone marrow ablation with bone-seeking radionuclides and in vitro purging of aspirated leukemic marrow for use in autologous marrow transplants, is presented. Phosphonic acid complexes of Sm-153 also localize in the skeleton and have found use in the palliation of bone pain. However, the dose distribution is uneven because these radiopharmaceuticals distribute according to available surface; 2-4 times the skeletal average in trabecular vs cortical bone. Thus, the marrow dose can vary. The authors' research group and the Radiation Interactions Division of NIST have announced the discovery that beta radiation-induced excited electrons are trapped in the hydroxyapatite mineral of bone and provide a potential direct dosimetric method for marrow dose when combined with routine bone marrow (and included bone) biopsies. The overall research plan sets the hypothesis that reduced morbidity marrow ablation can be successfully followed by bone marrow transplantation (BMT) with autologous marrow purged in vitro by antibody-targeted alpha emitters

  1. Line Identification of Atomic and Ionic Spectra of Holmium in the Near-UV. Part I. Spectrum of Ho i

    Energy Technology Data Exchange (ETDEWEB)

    Al-Labady, N.; Özdalgiç, B. [Graduate School of Engineering and Sciences, Istanbul University, TR-34452 Beyazıt, Istanbul (Turkey); Er, A.; Güzelçimen, F.; Öztürk, I. K.; Başar, Gö. [Faculty of Science, Department of Physics, Istanbul University, TR-34134 Vezneciler, Istanbul (Turkey); Kröger, S. [Hochschule für Technik und Wirtschaft Berlin, Wilhelminenhofstr. 75A, D-12459 Berlin (Germany); Kruzins, A.; Tamanis, M.; Ferber, R., E-mail: ikanat@istanbul.edu.tr [Laser Centre, The University of Latvia, Rainis Boulevard 19, LV-1586 Riga (Latvia)

    2017-02-01

    The Fourier Transform spectra of a Holmium hollow cathode discharge lamp have been investigated in the UV spectral range from 25,000 up to 31,530 cm{sup −1} (317 to 400 nm). Two Ho spectra have been measured with neon and argon as buffer gases. Based on the intensity ratios from these two spectra, a distinction was made between atomic and ionic lines (ionic lines are discussed in an accompanying paper). Using the known Ho i energy levels, 71 lines could be classified as transitions of atomic Ho, 34 of which have not been published previously. Another 32 lines, which could not be classified, are listed in the literature and assigned as atomic Ho. An additional 370 spectral lines have been assigned to atomic Ho based on the signal-to-noise ratio in the two spectra measured under different discharge conditions, namely with buffer gases argon and neon, respectively. These 370 lines have not been previously listed in the literature.

  2. PWR Blowdown Heat Transfer Separate-Effects Program. Thermal-Hydraulic Test Facility experimental data report for test 166S

    International Nuclear Information System (INIS)

    Clemons, V.D.; White, M.D.; Hedrick, R.A.

    1978-01-01

    Reduced instrument responses are presented for Thermal-Hydraulic Test Facility (THTF) test 166S, which is part of the ORNL Pressurized-Water Reactor (PWR) Blowdown Heat Transfer Separate-Effects Program. The objective of the program is to investigate the thermal-hydraulic phenomenon governing the energy transfer and transport processes that occur during a loss-of-coolant accident in a PWR system. Test 166S was conducted to obtain thermal-hydraulic and CHF information in THTF bundle 1 with an intact hot leg. The primary purpose of this report is to make the reduced instrument responses during tests 166S available. These are presented in graphical form in engineering units and have been analyzed only to the extent necessary to ensure reasonableness and consistency

  3. Top-gated field-effect LaAlO{sub 3}/SrTiO{sub 3} devices made by ion-irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hurand, S.; Jouan, A.; Feuillet-Palma, C.; Singh, G.; Malnou, M.; Lesueur, J.; Bergeal, N. [Laboratoire de Physique et d' Etude des Matériaux-CNRS-ESPCI ParisTech-UPMC, PSL Research University, 10 Rue Vauquelin - 75005 Paris (France); Lesne, E.; Reyren, N.; Barthélémy, A.; Bibes, M.; Villegas, J. E. [Unité Mixte de Physique CNRS-Thales, 1 Av. A. Fresnel, 91767 Palaiseau (France); Ulysse, C. [Laboratoire de Photonique et de Nanostructures LPN-CNRS, Route de Nozay, 91460 Marcoussis and Universit Paris Sud, 91405 Orsay (France); Pannetier-Lecoeur, M. [DSM/IRAMIS/SPEC - CNRS UMR 3680, CEA Saclay, F-91191 Gif-sur-Yvette Cedex (France)

    2016-02-01

    We present a method to fabricate top-gated field-effect devices in a LaAlO{sub 3}/SrTiO{sub 3} two-dimensional electron gas (2-DEG). Prior to the gate deposition, the realisation of micron size conducting channels in the 2-DEG is achieved by an ion-irradiation with high-energy oxygen ions. After identifying the ion fluence as the key parameter that determines the electrical transport properties of the channels, we demonstrate the field-effect operation. At low temperature, the normal state resistance and the superconducting T{sub c} can be tuned over a wide range by a top-gate voltage without any leakage. A superconductor-to-insulator quantum phase transition is observed for a strong depletion of the 2-DEG.

  4. Investigation of the integrated effects of irradiating platinum resistance thermometers

    International Nuclear Information System (INIS)

    Neverov, V.A.; Revyakin, Yu.L.

    1993-01-01

    The development of nuclear energy imposes increased demands on the reliability and quality of the information obtained from primary transducers which monitor the basic parameters of current reactor devices. One of these parameters is the temperature of different modules. This is mainly measured by thermoelectric transducers. Resistance thermometers now being adopted into measurement practice. These provide an initial accuracy of better than plus or minus 273 degrees C and also a normalized systematic error component caused by the action of the temperature. However, a systematic error component resulting from the action of the reactor radiation remains undetermined, and this greatly hinders the extensive use of resistance thermometers in reactor devices. Investigations were made using platinum resistance thermometers of different constructions designs. Irradiation took place in sealed ampules. Each of these contained three thermometers. The fluence achieved was varied by placing the ampules at different heights relative to the central plane of the active zone of the reactor. The irradiation temperature was determined by calculation, taking into account the radiative energy release where the irradiation occurred and the helium gap between the thermometer casing and the walls of an SM-2 reactor channel. Following irradiation in the reactor, the resistance thermometers were calibrated in a special thermometric device providing the minimum contact resistance, uniform heating of the samples, and stabilization of the temperature regime

  5. The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation

    International Nuclear Information System (INIS)

    Lee, Kyung Ja

    2008-01-01

    To evaluate the efficacy of a belly-board device (BBD) in reducing the volume of small bowel during four-field pelvic irradiation. Materials and Methods: Twenty-two cancer patients (14 uterine cervical cancer, 6 rectal cancer, and 2 endometrial cancer) scheduled to receive pelvic irradiation were selected for this study. Two sets of CT images were taken with and without the belly-board device using the Siemens 16 channel CT scanner. All patients were set in the prone position. The CT images were transferred to a treatment planning system for dose calculation and volume measurements. The external surfaces of small bowel and the bladder were contoured on all CT scans and the 4-pelvic fields were added. The dose-volume-histogram of the bladder and small bowel, with and without the BBD, were plotted and analyzed. Results: In all patients, the total small bowel volume included in the irradiated fields was reduced when the BBD was used. The mean volume reduction was 35% (range, 1-79%) and was statistically significant (p<0.001). The reduction in small bowel volume receiving 10-100% of the prescribed dose was statistically significant when the BBD was used in all cases. Almost no change in the total bladder volume involved was observed in the field (<8 cc, p=0.762). However, the bladder volume receiving 90% of the prescribed dose was 100% in 15/22 patients (68%) and 90-99% in 7/22 patients (32%) with the BBD. In comparison, the bladder volume receiving 90% of the prescribed dose was 100% in 10/22 patients (45%), 90-99% in 7/22 patients (32%), and 80-89% in 5/22 patients (23%) without the BBD. When the BBD was used, an increase in the bladder volume receiving a high dose range was observed Conclusion: This study shows that the use of a BBD for the treatment of cancer in the pelvic area significantly improves small bowel sparing. However, since the BBD pushed the bladder into the treatment field, the bladder volume receiving the high dose could increase. Therefore it is

  6. Performance of irradiated silicon microstrip detectors

    International Nuclear Information System (INIS)

    Catacchini, E.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Lenzi, M.; Meschini, M.; Parrini, G.; Pieri, M.

    1999-01-01

    Silicon microstrip devices to be installed in Large Hadron Collider (LHC) tracking detectors will have to operate in a high radiation environment. We report on performance studies of silicon microstrip detectors irradiated with neutrons or protons, up to fluences comparable to the first ten years of running at LHC. Obtained results show that irradiated detectors can still be operated with satisfactory signal-to-noise ratio,and in the case of inhomogeneously type inverted detector a very good position resolution is achieved regardless of the zone crossed by the particle

  7. Brazilian status in blood irradiation in Graft-Versus-Host Disease (GVHD) prevention

    International Nuclear Information System (INIS)

    Goes, E.G. de; Borges, J.C.; Ghilardi Netto, T.

    1996-01-01

    A short overview of the Brazilian reality concerning Graft-Versus-Host Disease (GVHD) is presented. Suggestions of policies and procedures to optimise GVHD prevention are reported. A national irradiator device using cobalt teletherapy unit is proposed for irradiation of blood and cellular components

  8. Experimental study on 14 MeV neutron irradiation effects in FLASH ROM28F256 and 29C256

    International Nuclear Information System (INIS)

    He Chaohui; Chen Xiaohua; Li Guozheng; Wang Yanping; Ji Lin; Geng Bin; Yang Hailiang; Liu Enke

    2000-01-01

    Experimental results of neutron irradiation effects are given for FLASH ROM. New phenomena are observed. The 14 MeV neutron irradiation effects in 28F256 and 29C256 devices are different from the single event effects. Errors are only '0'→'1'. There is a neutron flux threshold. Errors occur when neutron flux is above the threshold, no error occurs when below the threshold. The errors go up with the increase of the neutron flux until all '0' change to '1'. Hard errors, that new data cannot be written in memory with programmer, occur in devices which are measured during irradiation and irradiated in power on mode. Errors rise with the increase of reading times. Under same neutron flux, there is no error in devices in power off mode, however, errors occur in all devices in power on mode, moreover, undefined errors occur

  9. Devices for irradiation of materials in the fast neutron flux at the RA heavy water reactor in Vinca; Uredjaji za ozracivanje materijala u fluksu brzih neutrona na teskovodnom reaktoru RA u Vinci

    Energy Technology Data Exchange (ETDEWEB)

    Pavicevic, M [The Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1965-07-01

    Full text: This paper covers the concept, design description and problems of constructing special experimental devices at the RA reactor in Vinca. These devices were used for irradiation of construction materials (graphite, Mg and Al oxides, steel and zircaloy) in the integral fast neutron flux of 2 x 10{sup 20} n/cm{sup 2}. Temperature of samples cooled by heavy water circulating through the hollow uranium fuel elements was measured by thermocouples. Construction of the device, preparation of samples, related flux measurements as well as irradiation were done in cooperation with the nuclear center in Saclay, France. Brief review of the experiences gained in using these experimental spaces at the RA reactor as well as problems of transporting the irradiated capsules from Vinca to France is included. [Serbo-Croat] Pun tekst: Rad obuhvata koncepciju, tehnicki opis i probleme realizacije specijalnih eksperimentalnih uredjaja u reaktoru RA u Vinci, u kojima je tokom 1962. godine izvrseno, na temperaturama ispod 100 deg C, ozracivanje konstrukcionih materijala (grafita, Mg i Al-oksida, celika i cirkaloja) u integralnom fluksu brzih neutrona vrednosti 2 x 10{sup 20} n/cm{sup 2}. Temperatura uzoraka hladjenih teskom vodom, koja protice kroz suplje uranske elemente, merena je termoparovima. Realizacija uredjaja, priprema uzoraka, odgovarajuca merenja fluksa kao i sama ozracivanja vrsena su u saradnji sa Nuklearnim centrom u Saclay-u, Francuska. Dat je kraci pregled iskustava iz eksploatacije ovih novih eksperimentalnih prostora u reaktoru RA, kao i neki problemi vezani za transport aktivnih kapsula sa uzorcima od Vince do Saclay-a (author)

  10. Preparation and Quality Control of 166Ho-Boro-Macroaggregates for Radiosynoviorthesis

    Czech Academy of Sciences Publication Activity Database

    Kropáček, Martin; Melichar, František; Šrank, Jiří; Mirzajevová, Marcela; Klejzarová, Michaela; Kraft, O.; Kašpárek, R.; Záhlava, J.; Chodacki, A.

    2006-01-01

    Roč. 33, Suppl. 2 (2006), S327-S328 ISSN 1619-7070. [Annual Congress of the European Association of Nuclear Medicine. 01.10.2006-03.10.2006, Athens] R&D Projects: GA AV ČR(CZ) IQS10480501 Institutional research plan: CEZ:AV0Z10480505 Keywords : 166Ho- Boro -Macroaggregate * Radiosynoviorthesis Subject RIV: CH - Nuclear ; Quantum Chemistry

  11. Irradiation creep and stress-enhanced swelling of Fe-16Cr-15Ni-Nb austenitic stainless steel in BN-350

    Energy Technology Data Exchange (ETDEWEB)

    Vorobjev, A.N.; Porollo, S.I.; Konobeev, Yu.V. [Institute of Physics and Power Engineering, Obninsk (Russian Federation)] [and others

    1997-04-01

    Irradiation creep and void swelling will be important damage processes for stainless steels when subjected to fusion neutron irradiation at elevated temperatures. The absence of an irradiation device with fusion-relevant neutron spectra requires that data on these processes be collected in surrogate devices such as fast reactors. This paper presents the response of an annealed austenitic steel when exposed to 60 dpa at 480{degrees}C and to 20 dpa at 520{degrees}C. This material was irradiated as thin-walled argon-pressurized tubes in the BN-350 reactor located in Kazakhstan. These tubes were irradiated at hoop stresses ranging from 0 to 200 MPa. After irradiation both destructive and non-destructive examination was conducted.

  12. Quantitative Evaluation of Scintillation Camera Imaging Characteristics of Isotopes Used in Liver Radioembolization

    Science.gov (United States)

    Elschot, Mattijs; Nijsen, Johannes Franciscus Wilhelmus; Dam, Alida Johanna; de Jong, Hugo Wilhelmus Antonius Maria

    2011-01-01

    Background Scintillation camera imaging is used for treatment planning and post-treatment dosimetry in liver radioembolization (RE). In yttrium-90 (90Y) RE, scintigraphic images of technetium-99m (99mTc) are used for treatment planning, while 90Y Bremsstrahlung images are used for post-treatment dosimetry. In holmium-166 (166Ho) RE, scintigraphic images of 166Ho can be used for both treatment planning and post-treatment dosimetry. The aim of this study is to quantitatively evaluate and compare the imaging characteristics of these three isotopes, in order that imaging protocols can be optimized and RE studies with varying isotopes can be compared. Methodology/Principal Findings Phantom experiments were performed in line with NEMA guidelines to assess the spatial resolution, sensitivity, count rate linearity, and contrast recovery of 99mTc, 90Y and 166Ho. In addition, Monte Carlo simulations were performed to obtain detailed information about the history of detected photons. The results showed that the use of a broad energy window and the high-energy collimator gave optimal combination of sensitivity, spatial resolution, and primary photon fraction for 90Y Bremsstrahlung imaging, although differences with the medium-energy collimator were small. For 166Ho, the high-energy collimator also slightly outperformed the medium-energy collimator. In comparison with 99mTc, the image quality of both 90Y and 166Ho is degraded by a lower spatial resolution, a lower sensitivity, and larger scatter and collimator penetration fractions. Conclusions/Significance The quantitative evaluation of the scintillation camera characteristics presented in this study helps to optimize acquisition parameters and supports future analysis of clinical comparisons between RE studies. PMID:22073149

  13. Irradiated foodstuff: atom, junk-food and globalization; Aliments irradies: Atome, malbouffe et mondialisation

    Energy Technology Data Exchange (ETDEWEB)

    Azam, Genevieve; Berlan, Jean-Pierre; Desbordes, Roland; Dufour, Francois; Fievet, Yann; Folliard, Thierry; Gallais, Veronique; Hauter, Wenonah; Jacquiau, Christian; Kastler, Guy; Lannoye, Paul; Le Goff, Lylian; Le Rohellec, Catherine; Louchard, Olivier; Marechal, Gilles; Nicolas, Yveline; Remesy, Christian; Trouve, Aurelie; Veillerette, Francois

    2008-07-01

    Food irradiation is officially presented as an ideal technology at the service of worldwide health safety and as an alternative to chemical processing of foodstuff. It is first of all a multi-usage technology for the preservation, disinfestation, ripening slowing down, and germination inhibition of products which serves the interests of multinational companies of the agriculture and food industry. According to the authors, it is also an instrument for the globalization of foodstuff trade encouraged by the international institutions and by some governments. The book stresses on the health, socio-economic and environmental risks of this technology: vitamins loss, carcinogenesis, mutagenesis, impact on local employment and economy, risks linked with the use of irradiation devices etc

  14. 25 CFR 166.311 - Is an Indian agricultural resource management plan required?

    Science.gov (United States)

    2010-04-01

    ... holistic management objectives; and (5) Identify actions to be taken to reach established objectives. (c... 25 Indians 1 2010-04-01 2010-04-01 false Is an Indian agricultural resource management plan... WATER GRAZING PERMITS Land and Operations Management Management Plans and Environmental Compliance § 166...

  15. Status of food irradiation in Brazil

    International Nuclear Information System (INIS)

    Kikuchi, O.K.

    1996-01-01

    Research on food irradiation in Brazil started in 1968 at the Center of Nuclear Energy for Agriculture (CENA), Piracicaba, Sao Paulo. At the Institute of Nuclear and Energy Research (IPEN-CNEN/SP), Sao Paulo, Sao Paulo, research on detection of irradiated foods is in progress. In 1973, the Brazilian government established a regulation about food irradiation. Nowadays, the products authorized to be irradiated are: rice, poultry, fish and fish products, potatoes, onions, avocados, persimmons, pineapples, wheat flour, maize, beans, spices, tomatoes, guavas, oranges, lemons, strawberries, mangoes, melons and papayas. The other recommended products to be approved in the future are: acerolas, apples, beans (dose > 1 kGy), beef, blueberries, cherries, cheeses, coffee, figs, fresh guaranas, garlics, grapefruits, grapes, mushrooms, nuts and pork. Today, there is only one commercial facility for irradiation services in the country, the Empresa Brasileira de Radiacoes Ltda. (EMBRARAD). This company operates a Nordion JS-7500 irradiator, with a present activity of about 1,000 kCi, designed for sterilizing medical devices. It also irradiates spices, dried foods, gemstones, cosmetics, wood and raw materials for pharmaceuticals. The plant operates 24 hours a day and the spices and dried foods represent 15% of the business. Powder of guarana seeds is irradiated also for exportation. There are two other commercial facilities for radiation sterilization in Brazil, operating exclusively for their own production. (J.P.N.)

  16. Aspects of Low Temperature Irradiation in Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Brune, D.

    1968-08-01

    Neutron irradiation of the sample while frozen in a cooling device inserted in a reactor channel has been carried out in the analysis of iodine in aqueous samples as well as of mercury in biological tissue and water. For the simultaneous irradiation of a large number of aqueous solutions the samples were arranged in a suitable geometry in order to avoid mutual flux perturbation effects. The influence of the neutron temperature on the activation process has been discussed. Potential applications of the low temperature irradiation technique are outlined

  17. Aspects of Low Temperature Irradiation in Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Brune, D

    1968-08-15

    Neutron irradiation of the sample while frozen in a cooling device inserted in a reactor channel has been carried out in the analysis of iodine in aqueous samples as well as of mercury in biological tissue and water. For the simultaneous irradiation of a large number of aqueous solutions the samples were arranged in a suitable geometry in order to avoid mutual flux perturbation effects. The influence of the neutron temperature on the activation process has been discussed. Potential applications of the low temperature irradiation technique are outlined.

  18. Investigation of the agglomeration and amorphous transformation effects of neutron irradiation on the nanocrystalline silicon carbide (3C-SiC) using TEM and SEM methods

    Energy Technology Data Exchange (ETDEWEB)

    Huseynov, Elchin M., E-mail: elchin.h@yahoo.com [Department of Nanotechnology and Radiation Material Science, National Nuclear Research Center, Inshaatchilar pr. 4, AZ 1073 Baku (Azerbaijan); Institute of Radiation Problems of Azerbaijan National Academy of Sciences, B.Vahabzade 9, AZ 1143 Baku (Azerbaijan)

    2017-04-01

    Nanocrystalline 3C-SiC particles irradiated by neutron flux during 20 h in TRIGA Mark II light water pool type research reactor. Silicon carbide nanoparticles were analyzed by Scanning Electron Microscope (SEM) and Transmission Electron Microscopy (TEM) devices before and after neutron irradiation. The agglomeration of nanoparticles was studied comparatively before and after neutron irradiation. After neutron irradiation the amorphous layer surrounding the nanoparticles was analyzed in TEM device. Neutron irradiation defects in the 3C-SiC nanoparticles and other effects investigated by TEM device. The effect of irradiation on the crystal structure of the nanomaterial was studied by selected area electron diffraction (SAED) and electron diffraction patterns (EDP) analysis.

  19. Light-pulse atom interferometric device

    Science.gov (United States)

    Biedermann, Grant; McGuinness, Hayden James Evans; Rakholia, Akash; Jau, Yuan-Yu; Schwindt, Peter; Wheeler, David R.

    2016-03-22

    An atomic interferometric device useful, e.g., for measuring acceleration or rotation is provided. The device comprises at least one vapor cell containing a Raman-active chemical species, an optical system, and at least one detector. The optical system is conformed to implement a Raman pulse interferometer in which Raman transitions are stimulated in a warm vapor of the Raman-active chemical species. The detector is conformed to detect changes in the populations of different internal states of atoms that have been irradiated by the optical system.

  20. Electron trapping during irradiation in reoxidized nitrided oxide

    International Nuclear Information System (INIS)

    Mallik, A.; Vasi, J.; Chandorkar, A.N.

    1993-01-01

    Isochronal detrapping experiments have been performed following irradiation under different gate biases in reoxidized nitrided oxide (RNO) MOS capacitors. These show electron trapping by the nitridation-induced electron traps at low oxide fields during irradiation. A difference in the detrapping behavior of trapped holes and electrons is observed, with trapped holes being detrapped at relatively lower temperatures compared to trapped electrons. Electron trapping shows a strong dependence on tile magnitude of the applied gate bias during irradiation but is independent of its polarity. Conventional oxide devices, as expected, do not show any electron trapping during irradiation by the native electron traps. Finally, a comparison of the isochronal detrapping behavior following irradiation and following avalanche injection of electrons has been made to estimate the extent of electron trapping. The results show that electron trapping by the nitridation-induced electron traps does not play the dominant role in improving radiation performance of RNO, though its contribution cannot be completely neglected for low oxide field irradiations