WorldWideScience

Sample records for holmium monoxide hoo

  1. An early story of Kho Ping Hoo

    CW Watson

    2017-05-01

    Full Text Available Kho Ping Hoo (1926–1994 is the most well-known of all Indonesian writers of popular silat stories, largely set in China, which describe the adventures and romances of legendary heroes famed for their skill in martial arts. It is less well-known that he began his career writing critical stories about socio-economic conditions in the late 50s and early 60s. This paper discusses one of these stories. It places the story in the context of political developments of the time, in particular as they affected the Chinese Indonesian community. The paper argues that this story and one or two others like it come at the end of a tradition of Sino-Indonesian literature which had flourished from the end of the nineteenth century until the mid-1950s. After 1960, Chinese-Indonesian writers cease writing realist fiction of any kind and write either silat stories or romantic stories set in middle class urban environments.

  2. Psychometric properties of the French translation of the reduced KOOS and HOOS (KOOS-PS and HOOS-PS)

    Ornetti, P; Perruccio, A V; Roos, E M

    2009-01-01

    osteoarthritis (OA) in a rheumatology department were included. During the initial assessment, patients were asked to complete the Knee injury and Osteoarthritis Outcome Score (KOOS) or Hip disability and Osteoarthritis Outcome Score (HOOS) questionnaire and the OsteoArthritis Knee and Hip Quality Of Life...

  3. A Perspective on Helmberger and Hoos' Theory of Cooperatives

    Sexton, Richard J.

    1995-01-01

    Helmberger and Hoos' (HH) 1962 paper is a landmark in the economic theory of agricultural cooperatives, Along with the related work by Helmberger (1964), it represented the definitive treatment of marketing cooperative behavior and standard reading for graduate students in agricultural marketing for more than two decades, To understand fully HH's paper, appreciate its many strengths, and also recognize its weaknesses: one must interpret it both in the context of the work on cooperatives that ...

  4. The development of a short measure of physical function for hip OA HOOS-Physical Function Shortform (HOOS-PS)

    Davis, A M; Perruccio, A V; Canizares, M

    2008-01-01

    : The daily activity and sports and recreational items of the HOOS were reduced to five items achieving a feasible, short measure of physical function with interval level properties. This tool has potential for use as the function component of an OA severity scoring system. Further testing of this measure......OBJECTIVE: To derive a cross-culturally valid, short measure of physical function using function subscales (daily living and sports and recreation) of the Hip disability and Osteoarthritis Outcome Score (HOOS). METHODS: Rasch analysis was conducted on data from individuals from multiple countries...... who had hip osteoarthritis (OA). Fit of the data to the Rasch model was evaluated by model chi(2) and item fit statistics (chi(2), size of residual, and F-test). Differential item functioning was evaluated by gender, age and country. Unidimensionality was evaluated by factor analysis of residuals...

  5. Carbon monoxide

    NONE

    1994-12-31

    The document identifies the main sources of carbon monoxide (CO) in the general outdoor atmosphere, describes methods of measuring and monitoring its concentration levels in the United Kingdom, and discusses the effects of carbon monoxide on human health. Following its review, the Panel has put forward a recommendation for an air quality standard for carbon monoxide in the United Kingdom of 10 ppm, measured as a running 8-hour average. The document includes tables and graphs of emissions of CO, in total and by emission source, and on the increase in blood levels of carboxyhaemoglobin with continuing exposure to CO. 11 refs., 4 figs., 4 tabs.

  6. Magnetic structure of holmium-yttrium superlattices

    Jehan, D.A.; McMorrow, D.F.; Cowley, R.A.

    1993-01-01

    We present the results of a study of the chemical and magnetic structures of a series of holmium-yttrium superlattices and a 5000 angstrom film of holmium, all grown by molecular-beam epitaxy. By combining the results of high-resolution x-ray diffraction with detailed modeling, we show...... that the superlattices have high crystallographic integrity: the structural coherence length parallel to the growth direction is typically almost-equal-to 2000 angstrom, while the interfaces between the two elements are well defined and extend over approximately four lattice planes. The magnetic structures were...... determined using neutron-scattering techniques. The moments on the Ho3+ ions in the superlattices form a basal-plane helix. From an analysis of the superlattice structure factors of the primary magnetic satellites, we are able to determine separately the contributions made by the holmium and yttrium...

  7. Cross-cultural adaptation and validation of the reliability of the Thai version of the Hip disability and Osteoarthritis Outcome Score (HOOS).

    Trathitiphan, Warayos; Paholpak, Permsak; Sirichativapee, Winai; Wisanuyotin, Taweechok; Laupattarakasem, Pat; Sukhonthamarn, Kamolsak; Jeeravipoolvarn, Polasak; Kosuwon, Weerachai

    2016-10-01

    HOOS was developed as an extension of the Western Ontario and McMaster Universities' Osteoarthritis Index questionnaire for measuring symptoms and functional limitations related to the hip(s) of patients with osteoarthritis. To determine the validity and reliability of the Thai version of the Hip disability and Osteoarthritis Outcome Score (HOOS) vis-à-vis hip osteoarthritis, the original HOOS was translated into a Thai version of HOOS, according to international recommendations. Patients with hip osteoarthritis (n = 57; 25 males) were asked to complete the Thai version of HOOS twice: once then again after a 3-week interval. The test-retest reliability was analyzed using the intraclass correlation coefficient (ICC). Internal consistencies were analyzed using Cronbach's alpha, while the construct validity was tested by comparing the Thai HOOS with the Thai modified SF-36 and calculating the Spearman's rank correlation coefficients. The Thai HOOS produced good reliability (i.e., the ICC was greater than 0.9 in all five subscales). All of the Cronbach's alpha showed that the Thai HOOS had high internal consistency (Cronbach's alpha greater than 0.8), especially for the pain and ADL subscales (0.89 and 0.90, respectively). The Spearman's rank correlation for all five subscales of the Thai HOOS had moderate correlation with the Bodily Pain subscale of the Thai SF-36. The pain subscale of the Thai HOOS had a high correlation with the Vitality and Social Function subscales of the Thai SF-36 (r = 0.55 and 0.54)-with which the symptom subscale had a moderate correlation. The Thai version of HOOS had excellent internal consistency, excellent test-retest reliability, and good construct validity. It can be used as a reliable tool for assessing quality of life for patients with hip osteoarthritis in Thailand.

  8. Metrological traceability of holmium oxide solution

    Gonçalves, D. E. F.; Gomes, J. F. S.; Alvarenga, A. P. D.; Borges, P. P.; Araujo, T. O.

    2018-03-01

    Holmium oxide solution was prepared as a candidate of certified reference material for spectrophotometer wavelength scale calibration. Here is presented the necessary steps for evaluation of the uncertainty and the establishment of metrological traceability for the production of this material. Preliminary results from the first produced batch are shown.

  9. Comparative, validity and responsiveness of the HOOS-PS and KOOS-PS to the WOMAC physical function subscale in total joint replacement for osteoarthritis

    Davis, A M; Perruccio, A V; Canizares, M

    2009-01-01

    OBJECTIVE: To evaluate the internal consistency of the Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS) and the Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS) in total hip replacement (THR) and total knee (TKR) replacement....... Construct validity and responsiveness were compared to the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) Likert 3.0 physical function (PF) subscale and the PF excluding the items in the short measures (PF-exclusions). METHODS: Participants completed the full HOOS or KOOS, measures...... of fatigue, anxiety, depression and the Chronic Pain Grade (CPG) pre-surgery and the HOOS or KOOS 6 months post-surgery. Internal consistency for the HOOS-PS and KOOS-PS was calculated using Cronbach's alpha. For construct validity, it was hypothesized that correlations between the HOOS-PS or KOOS-PS and PF...

  10. Carbon Monoxide Information Center

    Full Text Available ... Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, ... Install one and check its batteries regularly. View Information About CO Alarms Other CO Topics Safety Tips ...

  11. Carbon Monoxide Information Center

    Full Text Available ... Education Safety Education Centers Carbon Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as CO, is called the " ...

  12. The People Next Door: Getting along with the Neighbors in "Yoo-Hoo Mrs. Goldberg" and "District 9"

    Beck, Bernard

    2010-01-01

    Two different perspectives on the immigrant struggles are found in a documentary about the radio and television program "The Goldbergs" and a science fiction thriller about the treatment of an immigrant alien community. "Yoo-Hoo Mrs. Goldberg" is optimistic and celebrates the achievements of an established ethnic community in America and the woman…

  13. Assessment of reliability, validity, responsiveness and minimally important change of the German Hip dysfunction and osteoarthritis outcome score (HOOS) in patients with osteoarthritis of the hip.

    Arbab, Dariusch; van Ochten, Johannes H M; Schnurr, Christoph; Bouillon, Bertil; König, Dietmar

    2017-12-01

    Patient-reported outcome measures are a critical tool in evaluating the efficacy of orthopedic procedures. The intention of this study was to evaluate reliability, validity, responsiveness and minimally important change of the German version of the Hip dysfunction and osteoarthritis outcome score (HOOS). The German HOOS was investigated in 251 consecutive patients before and 6 months after total hip arthroplasty. All patients completed HOOS, Oxford-Hip Score, Short-Form (SF-36) and numeric scales for pain and disability. Test-retest reliability, internal consistency, floor and ceiling effects, construct validity and minimal important change were analyzed. The German HOOS demonstrated excellent test-retest reliability with intraclass correlation coefficient values > 0.7. Cronbach´s alpha values demonstrated strong internal consistency. As hypothesized, HOOS subscales strongly correlated with corresponding OHS and SF-36 domains. All subscales showed excellent (effect size/standardized response means > 0.8) responsiveness between preoperative assessment and postoperative follow-up. The HOOS and all subdomains showed higher changes than the minimal detectable change which indicates true changes. The German version of the HOOS demonstrated good psychometric properties. It proved to be valid, reliable and responsive to the changes instrument for use in patients with hip osteoarthritis undergoing total hip replacement.

  14. Magnetodielectric coupling in multiferroic holmium iron garnets

    Malar Selvi, M.; Chakraborty, Deepannita; Venkateswaran, C.

    2017-01-01

    Single phase magneto-electric multiferroics require a large magnetic or electric field for producing magneto-electric (ME) and magnetodielectric (MD) effects. For utilizing these effects in devices investigations on the room temperature and low field MD studies are necessary. Recently, efforts have been largely devoted to the investigation of rare earth iron garnets. In the physical method, the preparation of rare earth iron garnet requires high sintering temperature and processing time. To solve these problems, ball milling assisted microwave sintering technique is used to prepare nanocrystalline holmium iron garnets (Ho_3Fe_5O_1_2). Magnetic and dielectric properties of the prepared sample are investigated. These properties get enhanced in nanocrystalline form when compared to the bulk. The MD coupling of the prepared sample is evident from the anomaly in the temperature dependent dielectric constant plot and the ME coupling susceptibility is derived from the room temperature MD measurements. - Highlights: • Formation of single phase Holmium iron garnet reported. • Ball milling assisted microwave sintering reduces the sintering temperature and time. • Holmium iron garnet shows enhanced magnetic and dielectric properties. • Pyromagnetic and pyroelectric measurements confirm the magnetoelectric coupling. • Room temperature magnetodielectric measurements show the nonlinear behaviour.

  15. Stone retropulsion during holmium:YAG lithotripsy.

    Lee, Ho; Ryan, R Tres; Teichman, Joel M H; Kim, Jeehyun; Choi, Bernard; Arakeri, Navanit V; Welch, A J

    2003-03-01

    We modeled retropulsion during holmium:YAG lithotripsy on the conservation of momentum, whereby the force of ejected fragment debris off of the calculous surface should equal the force of retropulsion displacing the stone. We tested the hypothesis that retropulsion occurs as a result of ejected stone debris. Uniform calculous phantoms were irradiated with holmium:YAG energy in air and in water. Optical fiber diameter and pulse energy were varied. Motion of the phantom was monitored with high speed video imaging. Laser induced crater volume and geometry were characterized by optical coherence tomography. To determine the direction of plume laser burn paper was irradiated at various incident angles. Retropulsion was greater for phantoms irradiated in air versus water. Retropulsion increased as fiber diameter increased and as pulse energy increased (p <0.001). Crater volumes increased as pulse energy increased (p <0.05) and generally increased as fiber diameter increased. Crater geometry was wide and shallow for larger fibers, and narrow and deeper for smaller fibers. The ejected plume propagated in the direction normal to the burn paper surface regardless of the laser incident angle. Retropulsion increases as pulse energy and optical fiber diameter increase. Vector analysis of the ejected plume and crater geometry explains increased retropulsion using larger optical fibers. Holmium:YAG lithotripsy should be performed with small optical fibers to limit retropulsion.

  16. Ethanolamine derivatives of dysprosium and holmium

    Gharia, K.S.; Singh, M.; Mathur, S.; Sankhla, B.S.

    1981-01-01

    The preparation and properties of dysprosium and holmium derivatives of mono-, di- and tri-ethanolamine derivatives are described. Compounds of general formulae: Ln(OPrsup(i)) 2 (mea), Ln(OPrsup(i))(mea) 2 , Ln(mea) 3 , Ln(OPrsup(i))(dea), Ln 2 (dea) 3 , Ln(dea)(deaH) and Ln(tea) (where Ln = Dy or Ho and mea, dea and tea are the anions of respective ethanolamine) were obtained and characterized by elemental analysis and IR spectra. (author)

  17. A cladding-pumped, tunable holmium doped fiber laser.

    Simakov, Nikita; Hemming, Alexander; Clarkson, W Andrew; Haub, John; Carter, Adrian

    2013-11-18

    We present a tunable, high power cladding-pumped holmium doped fiber laser. The laser generated >15 W CW average power across a wavelength range of 2.043 - 2.171 μm, with a maximum output power of 29.7 W at 2.120 μm. The laser also produced 18.2 W when operating at 2.171 µm. To the best of our knowledge this is the highest power operation of a holmium doped laser at a wavelength >2.15 µm. We discuss the significance of background losses and fiber design for achieving efficient operation in holmium doped fibers.

  18. Carbon Monoxide Safety

    ... with the Media Fire Protection Technology Carbon monoxide safety outreach materials Keep your community informed about the ... KB | Spanish PDF 592 KB Handout: carbon monoxide safety Download this handout and add your organization's logo ...

  19. Culture, power and identity The case of Ang Hien Hoo, Malang

    Melani Budianta

    2017-05-01

    Full Text Available This paper discusses the intricate relations between culture and identity in a web of larger power structures of politics and the market by looking at the ways in which the Indonesian Chinese attach themselves to a local performing arts tradition. The paper focuses on the history of the wayang orang amateur club called Ang Hien Hoo in Malang, East Java, which emerged from a Chinese diaspora burial association, to attract national limelight in the 1950s and 1960s. In this paper, I see this amateur club as a site, not only for cultural assimilation, but also as a meeting space for the diverse migrant Chinese population residing at a host country. The space is used to negotiate their position as citizens responsible to promote and to become patrons of local traditional performing arts. The paper examines how this amateur club was swept by the Cold War politics and national political turmoil of 1965, and how it fought to survive under the pressures of the global capitalist era. What emerges from the findings is the contradictory fact that the identification of the Chinese with the Javanese traditional performing arts is affirmed precisely as it is marked by Chineseness. Thus, despite the cultural blending, the Chinese Indonesian’s patronage of local traditional art continuously reproduces the double bind of making home in the culture not seen as their own.

  20. Carbon Monoxide Information Center

    Full Text Available ... main content Languages 简体中文 English Bahasa Indonesia 한국어 Español ภาษาไทย Tiếng Việt Text Size: Decrease Font Increase ... Monoxide Information Center Carbon Monoxide Information Center En Español The Invisible Killer Carbon monoxide, also known as ...

  1. Holmium laser enucleation of the prostate hyperplasia: technical aspects

    P. V. Glybochko

    2015-01-01

    Full Text Available Holmium laser enucleation of the prostate (HoLEP was first described by doctor P.J. Gilling et al. from New Zealand in 1996. The operation involves anatomical dissection of the prostatic tissue off the surgical capsule using a high-powered holmium laser followed by intravesical morsellation. The objective of this article is to explain the techniques for HoLEP.

  2. Cross-cultural adaptation and validation of the French version of the Hip disability and Osteoarthritis Outcome Score (HOOS) in hip osteoarthritis patients

    Ornetti, P; Parratte, S; Gossec, L

    2010-01-01

    osteoarthritis (OA). METHODS: The French version of the HOOS was developed according to published international guidelines to ensure content validity. The new version was then evaluated in two symptomatic hip OA populations, one with no indication for joint replacement (medical group), and the other waiting......OBJECTIVE: To translate and adapt the Hip disability and Osteoarthritis Outcome Score (HOOS) into French and to evaluate the psychometric properties of this new version, by testing feasibility, internal consistency, construct validity, reliability and responsiveness, in patients with hip...

  3. Crystal structure and phase composition of aluminium thin films with holmium additions

    Koleshko, V.M.; Belitskij, V.F.; Obukhov, V.E.; Rumak, N.V.; Urban, T.P.

    1984-01-01

    The effect of holmium additions on the crystal structure and phase composition of thin aluminium films has been studied. A regularity in grain size changes in aluminium thin films versus the holmium content in them is established. The holmium introduction is shown to result in the appearance of axial texture in the aluminium films, the texture axis being determined by the quantity of the addition. During heat treatment of the aluminium films, containing holmium additions, in the range of low ( approximately 100-200 deg C) annealing temperatures holmium monohydroxide is formed, and at annealing temperatures 300 deg C 0 3 is formed

  4. ANTIBACTERIAL PROPERTIES OF HOLMIUM TO CAUSATIVE AGENTS OF SUPPURATIVE -INFLAMMATORY COMPLICATIONS IN PATIENTS WITH TRAUMA

    Poddubnaya H. N.

    2012-06-01

    Full Text Available Article denotes to determination of antibacterial action of polyoxometalate holmium to causative agents of suppurative-inflammatory process in wounds of patients, which were suffered from trauma. Method of serial dilutions was used for determination of minimal inhibiting concentration (MIC of holmium to staphylococci, enterococci and E. coli. Registration of holmium action shows the strong antibacterial influence to staphylococci and enterococci (MIC of holmium action to staphylococcal and enterococcal strains same 1 10 M, to strains of E.coli – 2,5 10 M. Solutions of holmium don’t have antibacterial action to strains of E.coli.

  5. Use of the holmium:YAG laser in urology

    Mattioli, Stefano

    1997-12-01

    The Holmium-YAG is a versatile laser with multiple soft- tissue applications including tissue incision and vaporization, and pulsed-laser applications such as lithotripsy. At 2140 nanometers, the wavelength is highly absorbed by tissue water. Further, like CO2 laser, the Holmium produces immediate tissue vaporization while minimizing deep thermal damage to surrounding tissues. It is an excellent instrument for endopyelotomy, internal urethrotomy, bladder neck incisions and it can be used to resect the prostate. The Holmium creates an acute TUR defect which gives immediate results like the TURP. More than 50 patients were treated from Jan. 1996 to Jan. 1997 for obstructive symptoms due to benign prostatic hyperplasia, bladder neck stricture, urethral stenosis, and superficial bladder tumors.

  6. Holmium:YAG laser stapedotomy: preliminary evaluation

    Stubig, Ingrid M.; Reder, Paul A.; Facer, G. W.; Rylander, Henry G.; Welch, Ashley J.

    1993-07-01

    This study investigated the use of a pulsed Holmium:YAG ((lambda) equals 2.09 micrometers ) laser- fiber microsurgical system for laser stapedotomy. This system ablates human stapes bones effectively with minimal thermal damage. The study was designed to determine the effectiveness of the Ho:YAG laser (Schwartz Electro Optics, Inc., Orlando, FL) for stapedotomy and to evaluate temperature changes within the cochlea during the ablation process. Human cadaveric temporal bones were obtained and the stapes portion of the ossicular chain was removed. A 200 micrometers diameter low OH quartz fiber was used to irradiate these stapes bones in an air environment. The laser was pulsed at 2 Hz, 250 microsecond(s) ec pulse width and an irradiance range of 100 - 240 J/cm2 was used to ablate holes in the stapes footplate. The resultant stapedotomies created had smooth 300 micrometers diameter holes with a minimum of circumferential charring. Animal studies in-vivo were carried out in chinchillas to determine the caloric spread within the cochlea. A 0.075 mm Type T thermocouple was placed in the round window. Average temperature change during irradiation of the stapes footplate recorded in the round window was 3.6 degree(s)C. The data suggest that stapedotomy using the Ho:YAG laser can result in a controlled ablation of the stapes footplate with minimal thermal damage to the surrounding stapes. Optical coupling using fiberoptic silica fibers is an ideal method for delivering laser energy to the stapes during stapedotomy.

  7. Magnetoresistance in terbium and holmium single crystals

    Singh, R.L.; Jericho, M.H.; Geldart, D.J.W.

    1976-01-01

    The longitudinal magnetoresistance of single crystals of terbium and holmium metals in their low-temperature ferromagnetic phase has been investigated in magnetic fields up to 80 kOe. Typical magnetoresistance isotherms exhibit a minimum which increases in depth and moves to higher fields as the temperature increases. The magnetoresistance around 1 0 K, where inelastic scattering is negligible, has been interpreted as the sum of a negative contribution due to changes in the domain structure and a positive contribution due to normal magnetoresistance. At higher temperatures, a phenomenological approach has been developed to extract the inelastic phonon and spin-wave components from the total measured magnetoresistance. In the temperature range 4--20 0 K (approximately), the phonon resistivity varies as T 3 . 7 for all samples. Approximate upper and lower bounds have been placed on the spin-wave resistivity which is also found to be described by a simple power law in this temperature range. The implications of this result for theoretical treatments of spin-wave resistivity due to s-f exchange interactions are considered. It is concluded that the role played by the magnon energy gap is far less transparent than previously suggested

  8. Carbon monoxide poisoning

    ... Animals can also be poisoned by carbon monoxide. People who have pets at home may notice that their animals become ... or unresponsive from carbon monoxide exposure. Often the pets will ... these conditions. This can lead to a delay in getting help.

  9. Thermal property of holmium doped lithium lead borate glasses

    Usharani, V. L.; Eraiah, B.

    2018-04-01

    The new glass system of holmium doped lithium lead borate glasses were prepared by conventional melt quenching technique. The thermal stability of the different compositions of Ho3+ ions doped lithium lead borate glasses were studied by using TG-DTA. The Tg values are ranging from 439 to 444 °C with respect to the holmium concentration. Physical parameters like polaron radius(rp), inter-nuclear distance (ri), field strength (F) and polarizability (αm) of oxide ions were calculated using appropriate formulae.

  10. Psychometric properties of the OARSI/OMERACT osteoarthritis pain and functional impairment scales: ICOAP, KOOS-PS and HOOS-PS.

    Ruyssen-Witrand, A; Fernandez-Lopez, C J; Gossec, L; Anract, P; Courpied, J P; Dougados, M

    2011-01-01

    To evaluate the psychometric properties of the OARSI-OMERACT questionnaires in comparison to the existing validated scales. Consecutive hip or knee osteoarthritis patients consulting in an orthopedic department were enrolled in the study. Data collected were pain using the Intermittent and Constant Osteoarthritis Pain (ICOAP), a Numeric Rating Scale (NRS), the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) pain subscale, the Lequesne pain subscale; functional impairment using the Knee disability and Osteoarthritis Outcome Score-Physical Function Shortform (KOOS-PS), the Hip disability and Osteoarthritis Outcome Score-Physical Function Shortform (HOOS-PS), a NRS, the WOMAC function sub-scale, the Lequesne function subscale. Validity was assessed by calculating the Spearman's correlation coefficient between all the scales. Reliability was assessed in out-patients with stable disease comparing the data collected within 2 weeks using the intra-class correlation coefficient (ICC). Responsiveness was assessed on the data from hospitalised patients prior to and 12 weeks after a total joint replacement (TJR) using the standardised response mean. Three hundred patients (mean age=68 years, females=62%, hip OA=57%) were included. There was a moderate to good correlation between ICOAP, KOOS-PS, HOOS-PS and the WOMAC, NRS and Lequesne scales. Reliability of the ICOAP hip OA HOOS-PS and KOOS-PS was good (ICC range 0.80-0.81) whereas it was moderate for knee ICOAP (ICC=0.65). Responsiveness of the ICOAP, KOOS-PS and HOOS-PS 12 weeks after TJR was comparable to responsiveness of other scales (SRM range: 0.54-1.82). The psychometric properties of the ICOAP, KOOS-PS and HOOS-PS were comparable to those of the WOMAC, Lequesne and NRS.

  11. Assiut Experience in the Application of Holmium Laser in Treatment ...

    Assiut Experience in the Application of Holmium Laser in Treatment of Ureteral Calculi in Adults. A.M. Abdel Lateef, A.E. Abdel Moniem, M.I. Taha, M.A. Shalaby. Abstract. Internal Optical Urethrotomy at the National Medical Center of Sanou Souro in Bobo-Dioulasso: Feasibility, Safety and Short-Term Results Objective To ...

  12. Microspheres with Ultrahigh Holmium Content for Radioablation of Malignancies

    Bult, W.; Seevinck, P.R.; Krijger, G.C.; Visser, T.; Kroon-Batenburg, L.M.J.; Bakker, C.J.G.; Hennink, W.E.; van het Schip, A.D.; Nijsen, J.F.W.

    2009-01-01

    The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  13. Microspheres with ultrahigh holmium content for radioablation of malignancies

    Bult, W; Seevinck, P R; Krijger, G C; Visser, T; Kroon-Batenburg, L M J; Bakker, C J G; Hennink, W E; van het Schip, A D; Nijsen, J F W

    PURPOSE: The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  14. Microspheres with Ultrahigh Holmium Content for Radioablation of Malignancies

    Bult, W.; Seevinck, P.R.; Krijger, G.C.; Visser, T.; Kroon-Batenburg, L.M.J.; Bakker, C.J.G.; Hennink, W.E.; Van het Schip, A.D.; Nijsen, J.F.W.

    Purpose The aim of this study was to develop microspheres with an ultra high holmium content which can be neutron activated for radioablation of malignancies. These microspheres are proposed to be delivered selectively through either intratumoral injections into solid tumors or administered via an

  15. Compact high-field superconducting quadrupole magnet with holmium poles

    Barlow, D.B.; Kraus, R.H. Jr.; Lobb, C.T.; Menzel, M.T. (Los Alamos National Lab., NM (United States)); Walstrom, P.L. (Grumman Space Systems, Los Alamos, NM (United States))

    1992-03-15

    A compact high-field superconducting quadrupole magnet was designed and built with poles made of the rare-earth metal holmium. The magnet is intended for use in superconducting coupled-cavity linear accelerators where compact high-field quadrupoles are needed, but where the use of permanent magnets is ruled out because of trapped-flux losses. The magnet has a clear bore diameter of 1.8 cm, outside diameter of 11 cm, length of 11 cm, and pole tip length of 6 cm. The effect of using holmium, a material with a higher saturation field than iron, was investigated by replacing poles made of iron with identical poles made of holmium. The magnet was operated at a temperature of 4.2 K and reached a peak quadrupole field gradient of 355 T/m, a 10% increase over the same magnet with iron poles. This increase in performance is consistent with calculations based on B-H curves that were measured for holmium at 4.2 K. (orig.).

  16. Cross-cultural validation of the ICOAP and physical function short forms of the HOOS and KOOS in a multi-country study of patients with hip and knee osteoarthritis

    Mehta, S P; Sankar, A; Venkataramanan, V

    2016-01-01

    for total hip or knee replacement (THR or TKR). METHODS: Patients completed HOOS-PS or KOOS-PS, ICOAP and Western Ontario and McMaster Universities' Osteoarthritis Index (WOMAC) pain and physical function subscales at their consultation visit. Internal consistency was calculated using Cronbach's alpha....... The association of HOOS-PS/KOOS-PS and ICOAP with WOMAC pain and function subscales was calculated with Spearman correlation coefficients with 95% confidence intervals. RESULTS: HOOS-PS/KOOS-PS and ICOAP demonstrated high internal consistency across countries (alpha 0.75-0.96 (hip) and 0.76-0.95 (knee)). Both...

  17. Carbon Monoxide Information Center

    Full Text Available ... Unites States die every year from accidental non-fire related CO poisoning associated with consumer products, including ... CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of ...

  18. Carbon Monoxide Information Center

    Full Text Available ... On Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide ... Related Links Recalls Safety Education Regulations, Laws & Standards Research & Statistics Business & Manufacturing Small Business Resources OnSafety Blogs ...

  19. Carbon Monoxide Information Center

    Full Text Available ... Community Outreach Resource Center Toy Recall Statistics CO Poster Contest Pool Safely Business & Manufacturing Business & Manufacturing Business ... Featured Resources CPSC announces winners of carbon monoxide poster contest Video View the blog Clues You Can ...

  20. Occult carbon monoxide poisoning.

    Kirkpatrick, J N

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms when the source of carbon monoxide was removed. Exposed household pets provided an important clue to the diagnosis in some cases. Recurrent occult carbon monoxide poisoning may be a frequently overlooked cause of persistent or recurrent headache, fatigue, dizziness, paresthesias, abdominal pain, diarrhea and unusual spells.

  1. Carbon Monoxide Information Center

    Full Text Available ... Import Surveillance International Recall Guidance Civil and Criminal Penalties Federal Court Orders & ... 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 ...

  2. Carbon Monoxide Information Center

    Full Text Available ... Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths Associated with the Use of Consumer Products 2012 Annual Estimates OCTOBER 13, 2015 Incidents, Deaths, and In-Depth Investigations Associated with Non-Fire ...

  3. Carbon Monoxide Information Center

    Full Text Available ... Safety Blogs: CO Safety More CO Blogs Research & Statistics JANUARY 07, 2016 Non-Fire Carbon Monoxide Deaths ... 2011 Annual Estimates View All CO-Related Injury Statistics and Technical Reports Related Links Recalls Safety Education ...

  4. Carbon Monoxide Information Center

    Full Text Available ... CONSUMER PRODUCT SAFETY COMMISSION Search CPSC Search Menu Home Recalls Recall List CPSC Recall API Recall Lawsuits ... and Bans Report an Unsafe Product Consumers Businesses Home Safety Education Safety Education Centers Carbon Monoxide Information ...

  5. Carbon Monoxide Nonattainment Areas

    U.S. Environmental Protection Agency — This data layer identifies areas in the U.S. where air pollution levels have not met the National Ambient Air Quality Standards (NAAQS) for Carbon Monoxide and have...

  6. Occult Carbon Monoxide Poisoning

    Kirkpatrick, John N.

    1987-01-01

    A syndrome of headache, fatigue, dizziness, paresthesias, chest pain, palpitations and visual disturbances was associated with chronic occult carbon monoxide exposure in 26 patients in a primary care setting. A causal association was supported by finding a source of carbon monoxide in a patient's home, workplace or vehicle; results of screening tests that ruled out other illnesses; an abnormally high carboxyhemoglobin level in 11 of 14 patients tested, and abatement or resolution of symptoms ...

  7. Drug metabolism: Comparison of biodistribution profile of holmium in three different compositions in healthy Wistar rats

    Cerqueira-Coutinho, Cristal; Vidal, Lluis Pascual; Pinto, Suyene Rocha; Santos-Oliveira, Ralph

    2016-01-01

    Radioisotope holmium is a candidate to be used in cancer treatment and diagnosis. There are different holmium salts and they present distinct solubility and consequently different biodistribution profiles. In this work, we aimed to evaluate the biodistribution profiles of two holmium salts (chloride and sulfate) and holmium nanoparticles (oxide) through an in vivo biodistribution assay using animal model. Samples were labeled with technetium-99m and administered in Wistar rats by retro-orbital route. Holmium chloride is highly soluble in water and it was quickly filtered by the kidneys while holmium sulfate that presents lower solubility in water was mainly found in the liver and the spleen. However, both the salts showed a similar biodistribution profile. On the other hand, holmium oxide showed a very different biodistribution profile since it seemed to interact with all organs. Due to its particle size range (approximately 100 nm) it was not intensively filtered by the kidneys being found in high quantities in many organs, for this reason its use as a nanoradiopharmaceutical could be promising in the oncology field. - Highlights: • This article brings the biodistribution of holmium in 3 different compositions. • The results, as a technical note may help other researchers around the world to elucidate the mechanism (biological behavior) and the best strategy to use holmium as radiopharmaceutical.

  8. Carbon Monoxide Poisoning

    Kamal Mishra

    2016-01-01

    Full Text Available Introduction: Carbon monoxide is known as the silent killer, being colorless, odourless, and tasteless. Initially non-irritating, it is very difficult for people to detect Carbon monoxide is a product of incomplete combustion of organic matter due to insufficient oxygen supply that prevents complete oxidation of carbon to C02. During World War II, Nazis used gas vans to kill an estimated over 700,000 prisoners by carbon monoxide poisoning. This method was also used in the gas chambers ofseveral death camps. The true number of incidents of carbon monoxide poisoning is unknown, since many non-lethal exposures go undetected From the available data, carbon monoxide poisoning is the most common cause of injury and death due to poisoning worldwide. Clinical features and management: The signs of carbon monoxide poisoning vary with concentration and length of exposure. Subtle cardiovascular or neurobehavioural effects occur at low concentration. The onset of chronic poisoning is usually insidious and easily mistaken for viral prodrome, depression, or gastroenteritis in children. The classic sign of carbon monoxide poisoning which is actually more often seen in the dead than the living is appearing red-cheeked and healthy. Cherry pink colour develops in nails, skin and mucosa. In acute poisoning, common abnormalities of posture and tone are cogwheel rigidity, opisthotonus, spasticity or flaccidity and seizures. Retinal haemorrhages and the classic cherry red skin colour are seldom seen. Different people andpopulations may have different carbon monoxide tolerance levels. On average, exposures at 100ppm or greater is dangerous to human health. Treatment and prevention: The mainstay of treatment is 100% oxygen administration until the COHb level is normal When the patient is stable enough to be transported, hyperbaric oxygen (HBOT should be considered This treatment is safe and well tolerated Public education about the danger of carbon monoxide, with

  9. Carbon Monoxide Poisoning

    Alisa Wray

    2016-07-01

    Full Text Available Audience: This oral boards case is appropriate for all emergency medicine learners (residents, interns, and medical students. Introduction: Carbon monoxide (CO is a colorless and odorless gas that typically results from combustion. It binds hemoglobin, dissociating oxygen, causing headache, weakness, confusion and possible seizure or coma. Pulse oxygen levels may be falsely elevated. Practitioners should maintain a high index of suspicion for carbon monoxide poisoning. If caught early CO poisoning is reversible with oxygen or hyperbaric oxygen therapy. Objectives: The learner will assess a patient with altered mental status and weakness, ultimately identifying that the patient has carbon monoxide poisoning. The learner will treat the patient with oxygen and admit/transfer the patient for hyperbaric oxygenation. Method: Oral boards case

  10. Acupoint Massage in Relieving Pain after Ureteroscopic Holmium Laser Lithotripsy

    Xia Wei-qin

    2014-01-01

    Objective: To observe the effect of acupoint massage in relieving pain after ureteroscopic holmium laser lithotripsy. Methods: Ninety-two patients undergone ureteroscopic holmium laser lithotripsy were enrolled and randomized into a treatment group and a control group, 46 in each group. Patients in the control group were given regular nursing care, while patients in the treatment group were intervened by acupoint massage in addition to the regular nursing care. The pain was evaluated by visual analogue scale (VAS) at 6 h, 12 h, and 24 h after operation, and compared between the two groups. Results:There was no significant difference in comparing the VAS score at 6 h after operation between the two groups (P>0.05). The VAS scores in the treatment group at 12 h and 24 h after operation were significantly lower than those in the control group (both P Conclusion: Acupoint massage can effectively relieve the pain after ureteroscopic holmium laser lithotripsy, reduce the use of analgesics, and promote the recovery.

  11. Synthesis and ultrasonic characterisation of vitreous holmium phosphates

    Senin Hassan; Sidek Hj, Abdul Aziz; Abdul Halim Shaari

    1996-01-01

    The ultrasonic properties of holmium metaphosphate glasses (Ho sub 2 O sub 3) sub x (P sub 2 O sub 5) sub 1-x, with the mole fraction of x of holmium oxide equal to 0.208, 0.22 and 0.231 respectively, have been determined from measurements of the effects of temperature and hydrostatic pressure on ultrasonic wave velocities. At temperature below about 100K, the ultrasonic wave velocity of this type of rare earth phosphate glasses become anomalously dependent upon temperature; a behaviour associated with the interaction between acoustic phonons and two level systems. The hydrostatic pressure derivatives (∂ C sup S sub IJ / ∂ P) sub p=0 of the elastic stiffnesses C sub IJ and also (∂ C sup S sub IJ / ∂ P) sub p=0 of the bulk modulus B sup S of these glasses are anomalously negative. Both longitudinal γ sub L and shear γ sub S acoustic mode Gruneisen parameters are small and negative : the application of pressure softens the long-wavelength acoustic phonon mode frequencies. The results confirmed that the holmium phosphate glasses show an extraordinary elastic behaviour under high pressures

  12. Dysprosium (holmium) determination in the presence of erbium and dysprosium (holmium, erbium) determination in the presence of cerium

    Tolubara, A.I.; Kochubej, A.I.; Usatenko, Yu.I.

    1978-01-01

    Effect of salicylic acid upon complex formation in the systems REE - boronsulfoalizarinate, REE - oxine and REE - boronsulfoalizarinate - oxine is investigated. Comparison of optical characteristics of the above systems in the absence and in the presence of salicylic acid is carried out. It is established that in all the cases the effect of salicylic acid depends both on the nature of REE and the ratio of all the components of the system. Under certain conditions the given dependence is observed only for erbium complexes. Extraction-photometric methods of dysprosium and holmium determination in the presence of equal erbium amounts, as well as holmium and erbium determination in the presence of cerium equal amounts is developed

  13. Dysprosium (holmium) determination in the presence of erbium and dysprosium (holmium, erbium) determination in the presence of cerium

    Tolubara, A I; Kochubei, A I; Usatenko, Yu I

    1978-01-01

    Effect of salicylic acid upon complex formation in the systems REE - boronsulfoalizarinate, REE - oxine and REE - boronsulfoalizarinate - oxine is investigated. Comparison of optical characteristics of the above systems in the absence and in the presence of salicylic acid is carried out. It is established that in all the cases the effect of salicylic acid depends both on the nature of REE and the ratio of all the components of the system. Under certain conditions the given dependence is observed only for erbium complexes. Extraction-photometric methods of dysprosium and holmium determination in the presence of equal erbium amounts, as well as holmium and erbium determination in the presence of cerium equal amounts is developed.

  14. Carbon Monoxide Information Center

    Full Text Available ... Investigations Associated with Non-Fire Carbon Monoxide from Engine-Driven Generators and Other Engine-Driven Tools, 2004–2014 JANUARY 08, 2015 Non- ... outside of the Federal Government. CPSC does not control this external site or its privacy policy and ...

  15. Carbon Monoxide Information Center

    Full Text Available ... Español The Invisible Killer Carbon monoxide, also known as CO, is called the "Invisible Killer" because it's ... used or incorrectly-vented fuel-burning appliances such as furnaces, stoves, water heaters and fireplaces. Watch This ...

  16. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de; Osso Junior, Joao A.; Martinelli, Jose R.

    2011-01-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 ± 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  17. Microspheres with an ultra high holmium content for brachytherapy of malignancies

    Lira, Raphael A.; Myamoto, Douglas M.; Souza, Jaime R.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Biotecnologia; Osso Junior, Joao A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia; Martinelli, Jose R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Ciencias e Tecnologia de Materiais

    2011-07-01

    The overall objective of this work is to develop biodegradable microspheres intended for internal radiation therapy which provides an improved treatment for hepatic carcinomas. The most studied brachytherapy system employing microspheres made of holmium-biopolymer system is composed by poly(L-lactic acid) (PLLA) and holmium acetylacetonate (HoAcAc). The importance of the holmium high content in the microspheres can be interpreted as follow from a therapeutic standpoint, to achieve an effective use of microspheres loaded with HoAcAc, a high content of holmium is required to yield enough radioactivity with a relatively low amount of microspheres.The usual amounts of holmium that are incorporated in the microspheres composed by poly(L-lactic acid) and HoAcAc are 17.0 {+-} 0.5% (w/w) of holmium, which corresponds to a loading of about 50% of HoAcAc. Different approaches have been investigated to increase that value. One updated approach towards this direction is the production of microspheres with ultrahigh holmium as matrix using HoAcAc crystals as the sole starting material without the use of biopolymer. Likewise, in the search of microspheres with increased holmium content , it has been demonstrated that by changing the HoAcAc crystal structure by its recrystallization from crystal phase to the amorphous there is lost of acetylacetonate and water molecules causing the increasing of the holmium content. Microspheres were prepared by solvent evaporation, using holmium acetylacetonate (HoAcAc) crystals as the sole ingredient. Microspheres were characterized by using light and scanning electron microscopy, infrared and Raman spectroscopy, differential scanning calorimetry, X-rays diffraction, and confocal laser scanning microscopy. (author)

  18. Bacterium oxidizing carbon monoxide

    Kistner, A

    1953-01-01

    Present-day knowledge of the microbiological oxidation of carbon monoxide is based on doubtful observations and imperfect experimental procedures. By making use of shake cultures in contact with gas mixtures containing high concentrations of CO and by employing liquid enrichment media with a low content of organic matter and solid media of the same composition with not more than 1.2% agar, it proved possible to isolate a co-oxidizing bacterium of the genus hydrogenomonas from sewage sludge. For the first time irrefutable proof has been given of the oxidation of carbon monoxide by a pure culture of a bacterium, both in growing cultures and in resting cell suspensions. 12 references.

  19. Ocular brachytherapy with a holmium-166 irradiator device

    Mourao, Arnaldo P. [Centro Federal de Educacao Tecnoloica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Nucleo de Engenharia Hospitalar], e-mail: aprata@des.cefetmg.br; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares], e-mail: campos@nuclear.ufmg.br

    2009-07-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  20. Ocular brachytherapy with a holmium-166 irradiator device

    Mourao, Arnaldo P.; Campos, Tarcisio P.R.

    2009-01-01

    The ocular brachytherapy is a method that allows controlling ocular tumors. However, the irradiation of the ocular area in high doses can bring damages mainly to the surrounding healthy tissue, such as lens, retina and bone tissue of the orbital area in growth phase. Brachytherapy in comparison to teletherapy allows a large reduction of the absorbed doses in the adjacent tissues avoiding deleterious effects. Various types of radionuclides can be applied to ocular brachytherapy. Those radionuclides shall be encapsulated and placed juxtaposed to the sclera, back to the tumor. Herein, a new device was developed to encapsulate the radioactive material. It can easily place back of the eyeball. A computational model of the ocular area was developed in order to simulate the spatial dose distribution promoted by the holmium-166 nuclide distributed inside the irradiator device. The simulations addressed a device placed on the surface of the sclera, rotated 90 deg taken at the normal axis forward to the lens. The simulation was carried on the code Monte Carlo MCNP5. The computational simulation generates the spatial dose distribution in the treated volume. All continuous beta and the discrete gamma and X-ray spectra emitted by the holmium-166 were incorporated on simulations. The results allow comparing the space dose distribution to other types of sources used for the same end. The sclera absorbed dose, the maximum apical tumor dose, as well as on the tumor base were investigated. Indeed, the tumor thickness defines the conditions of irradiation. The holmium-166 dose distribution provides a tool to propose a better and optimized protocol for ocular brachytherapy. (author)

  1. Structural and optical properties of α-Fe2O3 nanoparticles, influence by holmium ions

    Mathevula, L. E.; Noto, L. L.; Mothudi, B. M.; Dhlamini, M. S.

    2018-04-01

    α-Fe2O3 and α-Fe2O3 doped with different concentration of holmium ions were synthesized by a simple sol-gel method. The XRD data confirmed the hexagonal structure of α-Fe2O3 for un-doped and holmium doped samples. The crystallite size was found to be decreasing with increasing holmium concentration. The amount of holmium was quantified using an EDS, which shows an increase in holmium quantity as concentration increases. The UV-Vis measurement shows an absorption edge around 570 nm. The band gap was estimated using the Kubelka-Munk relation and it was found to be fluctuating between 1.94 eV and 2.04 eV. The PL spectra confirmed the effect of holmium ions on luminescence properties of α-Fe2O3 which showed a maximum intensity at 0.1 mol% Holmium, and quenching as the concentration is increased from 0.3 mol% to 0.9 mol%.

  2. Synthesis, Characterization and Thermal Diffusivity of Holmium and Praseodymium Zirconates

    Stopyra M.; Niemiec D.; Moskal G.

    2016-01-01

    A2B2O7 oxides with pyrochlore or defected fluorite structure are among the most promising candidates for insulation layer material in thermal barrier coatings. The present paper presents the procedure of synthesis of holmium zirconate Ho2Zr2O7 and praseodymium zirconate Pr2Zr2O7 via Polymerized-Complex Method (PCM). Thermal analysis of precursor revealed that after calcination at relatively low temperature (700°C) fine-crystalline, single-phase material is obtained. Thermal diffusivity was me...

  3. Thermal Response to High-Power Holmium Laser Lithotripsy.

    Aldoukhi, Ali H; Ghani, Khurshid R; Hall, Timothy L; Roberts, William W

    2017-12-01

    The aim of this study was to investigate "caliceal" fluid temperature changes during holmium laser activation/lithotripsy using settings up to 40 W power output with different irrigation flow rates. The experimental system consisted of a glass test tube (diameter 10 mm/length 75 mm) filled with deionized water, to mimic a calix. Real-time temperature was recorded using a thermocouple (Physitemp, NJ) positioned 5 mm from the bottom of the tube. A 200 μm laser fiber (Flexiva; Boston Scientific, MA) was introduced through the working channel of a disposable ureteroscope (LithoVue; Boston Scientific) and the laser fiber tip was positioned 15 mm above the bottom of the test tube. Deionized water irrigation (room temperature) through the working channel of the ureteroscope was delivered at flow rates of 0, 7-8, 14-15, and 38-40 mL/minute. A 120-W holmium laser (pulse 120; Lumenis, CA) was used. The following settings were explored: 0.5 J × 10 Hz, 1.0 J × 10 Hz, 0.5 J × 20 Hz, 1.0 J × 20 Hz, 0.5 J × 40 Hz, 1.0 J × 40 Hz, and 0.5 J × 80 Hz. During each experiment, the laser was activated continuously for 60 seconds. Temperature increased with increasing laser power output and decreasing irrigation flow rate. The highest temperature, 70.3°C (standard deviation 2.7), occurred with laser setting of 1.0 J × 40 Hz and no irrigation after 60 seconds of continuous laser firing. None of the tested laser settings and irrigation parameters produced temperature exceeding 51°C when activated for only 10 seconds of continuous laser firing. High-power holmium settings fired in long bursts with low irrigation flow rates can generate high fluid temperatures in a laboratory "caliceal" model. Awareness of this risk allows urologist to implement a variety of techniques (higher irrigation flow rates, intermittent laser activation, and potentially cooled irrigation fluid) to control and mitigate thermal

  4. Synthesis and Characterization of Holmium-Doped Iron Oxide Nanoparticles

    Maarten Bloemen

    2014-02-01

    Full Text Available Rare earth atoms exhibit several interesting properties, for example, large magnetic moments and luminescence. Introducing these atoms into a different matrix can lead to a material that shows multiple interesting effects. Holmium atoms were incorporated into an iron oxide nanoparticle and the concentration of the dopant atom was changed in order to determine its influence on the host crystal. Its magnetic and magneto-optical properties were investigated by vibrating sample magnetometry and Faraday rotation measurements. The luminescent characteristics of the material, in solution and incorporated in a polymer thin film, were probed by fluorescence experiments.

  5. The Byzantine Silver Bowls in the Sutton Hoo Ship Burial and Tree-Worship in Anglo-Saxon England

    Michael D. J. Bintley

    2011-12-01

    Full Text Available The ten Byzantine silver bowls included amongst the grave goods interred in the chamber of the Mound 1 ship burial at Sutton Hoo remain one of the most puzzling features of this site. It has been suggested that these items, which lay separated from the rest of the silver in the burial and close to the head of the body-space (where no body was found, may have had some special meaning which has never been discovered. This paper will argue that one of the possible keys to unlocking their significance may be found in the central roundel that adorns the centre of each bowl in the form of a rosette. These bowls, which are thought to have been manufactured in the eastern provinces of the Byzantine Empire in c. 600, entered the British Isles in unknown circumstances before coming into the possession of the man buried in (or commemorated by the Mound 1 burial. Through comparison with contemporary sculpture and vernacular literature, I will suggest that this central rosette, which was associated with both the cross of Christ and sacred trees in Byzantine sculpture, may have served as a conventional bridge between Christian and pre-Christian religious traditions associated with sacred trees in Anglo-Saxon England. The central rosettes adorning each of these bowls may have been understood as the flower of a sacred tree. Since the latter appears to have figured in Anglian paganism it is possible that the bowls may helped to convert the Anglian aristocracy, bridging a gap between Germanic insular religious traditions and those that were being introduced to Britain at the time that the ship burial itself took place.

  6. Dynamics of pulsed holmium:YAG laser photocoagulation of albumen

    Pfefer, T.J.; Welch, A.J.

    2000-01-01

    The pulsed holmium:YAG laser (λ = 2.12 μm, τ p = 250 μs) has been investigated as a method for inducing localized coagulation for medical procedures, yet the dynamics of this process are not well understood. In this study, photocoagulation of albumen (egg white) was analysed experimentally and results compared with optical-thermal simulations to investigate a rate process approach to thermal damage and the role of heat conduction and dynamic changes in absorption. The coagulation threshold was determined using probit analysis, and coagulum dynamics were documented with fast flash photography. The nonlinear computational model, which included a Beer's law optical component, a finite difference heat transfer component and an Arrhenius equation-based damage calculation, was verified against data from the literature. Moderate discrepancies between simulation results and our experimental data probably resulted from the use of a laser beam with an irregular spatial profile. This profile produced a lower than expected coagulation threshold and an irregular damage distribution within a millisecond after laser onset. After 1 ms, heat conduction led to smoothing of the coagulum. Simulations indicated that dynamic changes in absorption led to a reduction in surface temperatures. The Arrhenius equation was shown to be effective for simulating transient albumen coagulation during pulsed holmium:YAG laser irradiation. Greater understanding of pulsed laser-tissue interactions may lead to improved treatment outcome and optimization of laser parameters for a variety of medical procedures. (author)

  7. Holmium laser enucleation versus laparoscopic simple prostatectomy for large adenomas.

    Juaneda, R; Thanigasalam, R; Rizk, J; Perrot, E; Theveniaud, P E; Baumert, H

    2016-01-01

    The aim of this study is to compare Holmium laser enucleation of the prostate with another minimally invasive technique, the laparoscopic simple prostatectomy. We compared outcomes of a series of 40 patients who underwent laparoscopic simple prostatectomy (n=20) with laser enucleation of the prostate (n=20) for large adenomas (>100 grams) at our institution. Study variables included operative time and catheterization time, hospital stay, pre- and post-operative International Prostate Symptom Score and maximum urinary flow rate, complications and economic evaluation. Statistical analyses were performed using the Student t test and Fisher test. There were no significant differences in patient age, preoperative prostatic size, operating time or specimen weight between the 2 groups. Duration of catheterization (P=.0008) and hospital stay (P.99). Holmium enucleation of the prostate has similar short term functional results and complication rates compared to laparoscopic simple prostatectomy performed in large glands with the advantage of less catheterization time, lower economic costs and a reduced hospital stay. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Dielectric and conducting behaviour of polycrystalline holmium octa-molybdate

    Want, Basharat; Zahoor Ahmad, Bhat; Hamid Bhat, Bilal

    2014-01-01

    Polycrystalline holmium octa-molybdate spherulites have been obtained by using gel diffusion technique and characterized by different physio-chemical techniques. The surfaces of these spherulites are composed of nano-rod with an average diameter of about 80 nm. At room temperature the initial crystal structure is triclinic, space group P1. Thermal studies suggested a phase transition occurring in holmium octa-molybdate crystals at about 793 K. The electrical properties of the system have been studied as a function of frequency and temperature in the ranges of 20 Hz–3 MHz and 290–570 K, respectively. A giant dielectric constant and two loss peaks have been observed in the permittivity formalism. The conducting behaviour of the material is also discussed. The conductivity was found to be 1572 μ Ω −1 m −1 at room temperature and 3 MHz frequency. The conductivity of the polycrystalline material was attributed to the fact that it arises due to the migration of defects on the oxygen sub-lattice. Impedance studies were also performed in the frequency domain to infer the bulk and grain boundary contributions to the overall electric response of the material. The electrical responses have been attributed to the grain, grain-boundary, and interfacial effects. (paper)

  9. Holmium laser use in the treatment of selected dry eye syndrome complications

    Kecik, Dariusz; Kecik, Tadeusz; Kasprzak, Jan; Kecik, Mariusz

    1996-03-01

    The authors present initial results of treatment selected complications of dry eye syndrome with holmium laser. The lacrimal puncta obliteration and coagulation of the corneal ulcer surface were done.

  10. HOLMIUM LASER ENUCLEATION OF THE PROSTATE, FEATURES OF THE INTERVENTION

    O. Y. Hublarov

    2014-01-01

    Full Text Available Holmium laser enucleation of the prostate (HoLEP is a minimally invasive procedure used for the treatment of benign prostatic hyperplasia. The method is as reliable performance with long-term monitoring, and high safety compared to conventional methods of surgical treatment of prostatic hyperplasia – suprapubic simple prostatectomy and transurethral resection of the prostate. Despite the complexity and duration of training for mastering HoLEP currently has a definite Frortage of references detailing the technical aspects of the method. The proposed article is detailed recommendations skilled mastering HoLEP. The material is based on a review of existing literature and my own experience and clinical material Latgale Urology Center in the development and conduct of HoLEP. 

  11. Iron monoxide photodissociation

    Chestakov, D. A.; Parker, D. H.; Baklanov, A. V.

    2005-02-01

    The photodissociation of Fe56O was studied by means of the velocity map imaging technique. A molecular beam of iron atoms and iron monoxide molecules was created using an electrical discharge with an iron electrode in a supersonic expansion of molecular oxygen. The ground state iron atom Fe(D45) and FeO concentrations in the molecular beam have been estimated. The dissociation energy of the FeO XΔ5 ground electronic state was found to be D00(FeO )=4.18±0.01eV. The effective absorption cross section of FeO at 252.39nm (vac), leading to the Fe(D45)+O(P3) dissociation channel, is ˜1.2×10-18cm2. A (1+1) resonantly enhanced multiphoton ionization spectrum of Fe56O in the region 39550-39580 cm-1 with rotational structure has been observed, but not assigned. Angular distributions of Fe(D45) and Fe(D35) products for the channel FeO →Fe(D4,35)+O(P3) have been measured at several points in the 210-260nm laser light wavelength region. The anisotropy parameter varies strongly with wavelength for both channels.

  12. Holmium laser enucleation for prostate adenoma greater than 100 gm.: comparison to open prostatectomy.

    Moody, J A; Lingeman, J E

    2001-02-01

    Options for treatment of large (greater than 100 gm.) prostatic adenomas have until now been limited to open surgery or transurethral resection by skilled resectionists. Considerable blood loss, morbidity, extended hospital stay and prolonged recovery occur with open surgery for large prostatic adenomas. Endoscopic surgery for benign prostatic hyperplasia has evolved during the last decade to offer the patient and surgeon significant advantages of transurethral removal of prostatic adenomas. Holmium laser enucleation of the prostate with transurethral tissue morcellation provides significant reductions in morbidity, bleeding and hospital stay for patients with large prostate adenomas. A retrospective review of data on 10 cases of holmium laser enucleation and 10 open prostatectomies for greater than 100 gm. prostatic adenomas was performed from 1998 to 1999 at our institution. Patient demographics, indication for surgery, preoperative and postoperative American Urological Association (AUA) symptom scores, operating time, serum hemoglobin, resected prostatic weight, pathological diagnosis, length of stay and complications were compared. Patient age, indications for surgery (retention, failed medical therapy, high post-void residual, bladder calculi, bladder diverticula and azotemia) and preoperative AUA symptom scores were similar in both groups. Postoperative AUA symptom scores were significantly decreased (p gm., p = 0.0003). Resected weight was greater in the holmium laser enucleation group (151 versus 106 gm., p = 0.07). Length of stay was significantly shorter in the holmium laser enucleation group (2.1 versus 6.1 days, p <0.001). Complications in the holmium laser enucleation group included stress urinary incontinence in 4 cases, prostatic perforation in 1 and urinary retention in 1. No patient treated with holmium laser enucleation was discharged home with an indwelling catheter. Complications in the open prostatectomy group included bladder neck contractures

  13. Conduction and stability of holmium titanium oxide thin films grown by atomic layer deposition

    Castán, H., E-mail: helena@ele.uva.es [Department of Electronic, University of Valladolid, 47011 Valladolid (Spain); García, H.; Dueñas, S.; Bailón, L. [Department of Electronic, University of Valladolid, 47011 Valladolid (Spain); Miranda, E. [Departament d' Enginyería Electrònica, Universitat Autónoma de Barcelona, 08193 Bellaterra (Spain); Kukli, K. [Department of Chemistry, University of Helsinki, FI-00014 Helsinki (Finland); Institute of Physics, University of Tartu, EE-50411,Tartu (Estonia); Kemell, M.; Ritala, M.; Leskelä, M. [Department of Chemistry, University of Helsinki, FI-00014 Helsinki (Finland)

    2015-09-30

    Holmium titanium oxide (HoTiO{sub x}) thin films of variable chemical composition grown by atomic layer deposition are studied in order to assess their suitability as dielectric materials in metal–insulator–metal electronic devices. The correlation between thermal and electrical stabilities as well as the potential usefulness of HoTiO{sub x} as a resistive switching oxide are also explored. It is shown that the layer thickness and the relative holmium content play important roles in the switching behavior of the devices. Cycled current–voltage measurements showed that the resistive switching is bipolar with a resistance window of up to five orders of magnitude. In addition, it is demonstrated that the post-breakdown current–voltage characteristics in HoTiO{sub x} are well described by a power-law model in a wide voltage and current range which extends from the soft to the hard breakdown regimes. - Highlights: • Gate and memory suitabilities of atomic layer deposited holmium titanium oxide. • Holmium titanium oxide exhibits resistive switching. • Layer thickness and holmium content influence the resistive switching. • Low and high resistance regimes follow a power-law model. • The power-law model can be extended to the hard breakdown regime.

  14. Effect of silver nanoparticles on the dielectric properties of holmium doped silica glass

    Rejikumar, P.R.; Jyothy, P.V.; Mathew, Siby; Thomas, Vinoy; Unnikrishnan, N.V.

    2010-01-01

    The effect of silver nanoparticle co-doping on the dielectric properties of holmium doped silica glasses was studied. Silver nanoparticles of size between 20 and 22 nm were produced by the sol-gel technique. One of the samples showed an icosahedral morphology of the nanocrystal formed, along with spherical morphology. It was found that the tuning of the dielectric constant values could be accomplished by co-doping. The sample, with 1 wt% of Ho, had low dielectric constant values within the range 100 Hz-3 MHz due to the formation of quasi-molecular structures of holmium. This effect was evaded to some extent with silver co-doping as a result of the interdispersion of holmium complexes. Also it was found that the co-doping produced a higher dielectric loss which was calculated from the tan δ-log f graph. The Cole-Cole parameters and the Jonscher power law parameters were also calculated and are presented.

  15. Chitosan microspheres loaded with holmium-165 produced by spray dryer for liver cancer therapy: preliminary experiments

    Miyamoto, Douglas Massao; Pires, Geovanna; Lira, Raphael A. de; Melo, Vitor H.S.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de; Osso Junior, Joao Alberto

    2011-01-01

    Chitosan is a biopolymer of 2-deoxy-2-amino-D-glucose that is obtained by deacetylation of chitin. It's biocompatible, biodegradable, non toxic and has antitumor activity. Chitosan has many applications, such as their microparticles that can be used to treat prostate cancer, rheumatoid arthritis, and for liver tumor brachytherapy treatment. Our group is developing different biodegradable polymer-based microspheres loaded with holmium-165 for this purpose. The Chitosan microspheres were produced loaded with holmium (III) chloride, and not loaded with it, by Mini Spray Dryer procedure. The microspheres were evaluated by scanning electron microscopy, energy dispersive spectroscopy (EDS), confocal laser scanning microscopy, thermogravimetric analysis, particle size, and X-ray diffraction. The EDS analysis confirmed the holmium chloride presence into the prepared chitosan microparticles. (author)

  16. Chitosan microspheres loaded with holmium-165 produced by spray dryer for liver cancer therapy: preliminary experiments

    Miyamoto, Douglas Massao; Pires, Geovanna; Lira, Raphael A. de; Melo, Vitor H.S.; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de, E-mail: douglas.miyamoto@usp.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Osso Junior, Joao Alberto [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Radiofarmacia

    2011-07-01

    Chitosan is a biopolymer of 2-deoxy-2-amino-D-glucose that is obtained by deacetylation of chitin. It's biocompatible, biodegradable, non toxic and has antitumor activity. Chitosan has many applications, such as their microparticles that can be used to treat prostate cancer, rheumatoid arthritis, and for liver tumor brachytherapy treatment. Our group is developing different biodegradable polymer-based microspheres loaded with holmium-165 for this purpose. The Chitosan microspheres were produced loaded with holmium (III) chloride, and not loaded with it, by Mini Spray Dryer procedure. The microspheres were evaluated by scanning electron microscopy, energy dispersive spectroscopy (EDS), confocal laser scanning microscopy, thermogravimetric analysis, particle size, and X-ray diffraction. The EDS analysis confirmed the holmium chloride presence into the prepared chitosan microparticles. (author)

  17. Radiopharmaceuticals of DTPA, DMSA and EDTA labeled with holmium-166

    Rahman, M.; Matsouka, H.; Takami, S.; Terunuma, K.

    2001-01-01

    DTPA, DMSA and EDTA were labelled with 166 Ho of low specific activity, 250-275mCi/mg of Ho, produced from holmium oxide by the 165 Ho(n, g) 166 Ho reaction at a neutron flux of about 10 14 n.cm -2 .s -1 . Three pH ranges were selected in the study, viz. 2-3, 3-3.5 and 5-6. The labelling reactions were studied as chloride and nitrate solutions in aqueous and saline media at 30 min and 20-24 h of reaction. DTPA was labelled over 99, DMSA at about 90 and EDTA at 100.0% with 166 Ho. The complexes were found stable at all times of investigation. A beta chromatogram scanner was used to study by TLC the labelling reactions of DTPA and DMSA with the nuclide and by PC those of EDTA. A biodistribution study in three rats injected intravenous with a saline solution of 166 HoCl 3 [DTPA] at pH5.1 showed an initial uptake in blood, kidney and lung after 30 minutes. After four hours the complex was found to have cleared from blood and lung, and localized 100% in kidney. It was stable in vivo in the kidney after 24 hours. The g spectrum analysis did not show the formation of any impurity except the four characteristic g energies of 166 Ho. (author)

  18. Holmium-166-chico intracavitary radiation therapy for cystic brain tumors

    Rhee, C. H.; Lee, S. H.; Jang, J. S.; Kim, E. H.; Choi, C. W.; Hong, S. W.; Lim, S. M. [Korea Cancer Center, Seoul (Korea, Republic of)

    1997-07-01

    Holmium-166-chitosan complex (Ho-166-chico) is injected into the unresectable seven cystic brain tumors (2 cases of metastatic brain tumors from lung cancer, 1 case of recurrent trigeminal neurinoma, 3 cases of recurrent low grade cystic astrocytomas, and 1 case of craniopharyngioma). The Ommaya reservoir was installed stereotactically. The cyst volume and wall thickness were measured by MRI before Ho-166-chico injection. The thickness of the cyst wall is up to 4 mm. Ho-166-chico (555-740 MBq) injected into the cyst to result in 25 Gy of dose to a cyst wall at a depth of 4 mm. Dose to the cyst wall was estimated by Monte Carlo simulation using the EGS4 code. All Ho-166-chico injected was assumed to be uniformly distributed in the spherical cyst. After Ho-166-chico injection, the distribution of isotopes was monitored by gamma camera. Two injections were administrated in two cases, and one injection in all the others. The response was evaluated with MRI. Four of 7 cases were shrunk in size with thinning of the cyst wall, 2 of 7 cases showed growth arrest, and one case showed progression. Estimated surface dose of cyst wall was between 78 and 2566 Gy. No one showed systemic absorption of Ho-166-chico, and specific complication associated with isotope injection. Ho-166-chico intracavitary radiation therapy for cystic brain tumor may be safe, and reliable method and deserves further evaluation.

  19. Optical and electrical doping of silicon with holmium

    Suyver, J.F.; Kik, P.G.; Kimura, T.; Polman, A.; Franzo, G.; Coffa, S.

    1999-01-01

    2 MeV holmium ions were implanted into Czochralski grown Si at a fluence of 5.5x10 14 Ho/cm 2 . Some samples were co-implanted with oxygen to a concentration of (7±1)x10 19 cm -3 . After recrystallization, strong Ho segregation to the surface is observed, which is fully suppressed by co-doping with O. After recrystallization, photoluminescence peaks are observed at 1.197, 1.96 and 2.06 μm, characteristic for the 5 I 6 → 5 I 8 and 5 I 7 → 5 I 8 transitions of Ho 3+ . The Ho 3+ luminescence lifetime at 1.197 μm is 14 ms at 12 K. The luminescence intensity shows temperature quenching with an activation energy of 11 meV, both with and without O co-doping. The observed PL quenching cannot be explained by free carrier Auger quenching, but instead must be due to energy backtransfer or electron hole pair dissociation. Spreading resistance measurements indicate that Ho exhibits donor behavior, and that in the presence of O the free carrier concentration is enhanced by more than two orders of magnitude. In the O co-doped sample 20% of the Ho 3+ was electrically active at room temperature

  20. Synthesis, Characterization and Thermal Diffusivity of Holmium and Praseodymium Zirconates

    Stopyra M.

    2016-06-01

    Full Text Available A2B2O7 oxides with pyrochlore or defected fluorite structure are among the most promising candidates for insulation layer material in thermal barrier coatings. The present paper presents the procedure of synthesis of holmium zirconate Ho2Zr2O7 and praseodymium zirconate Pr2Zr2O7 via Polymerized-Complex Method (PCM. Thermal analysis of precursor revealed that after calcination at relatively low temperature (700°C fine-crystalline, single-phase material is obtained. Thermal diffusivity was measured in temperature range 25-200°C, Ho2Zr2O7 exhibits lower thermal diffusivity than Pr2Zr2O7. Additionally, PrHoZr2O7 was synthesized. The powder in as-calcined condition is single-phase, but during the sintering decomposition of solid solution took place and Ho-rich phase precipitated. This material exhibited the best insulating properties among the tested ones.

  1. Ureteroscopic holmium laser cutting for inadvertently sutured drainage tube (report of five cases).

    Gao, Xu; Lu, Xin; Ren, Shancheng; Xu, Chuanliang; Sun, Yinghao

    2008-07-01

    The aim of this paper is to report a simple solution for inadvertently sutured drainage tube after urological surgery and discuss the different managements according to different types of this embarrassing complication. From September 2001 to January 2007, five inadvertently sutured drainage tubes were treated with ureteroscopic holmium laser cutting for the suture. All drainage tubes were removed after the operation without other complications. Holmium laser cutting via ureteroscope is a simple solution for the embarrassing problem of inadvertently sutured drainage tube. It can save the patient from undergoing another open surgery.

  2. Holmium laser lithotripsy (HoLL) of ureteral calculi

    Kuntz, Rainer M.; Lehrich, Karin; Fayad, Amr

    2001-05-01

    The effectiveness and side effects of ureteroscopic HoLL of ureteral stones should be evaluated. In 63 patients (17 female, 46 males) a total of 75 stones of 3-20 mm diameter were treated with ureteroscopic HoLL. 18.7 percent of stones were located in the proximal third, 24.0 percent in the middle third and 57.3 percent in the distal third of the ureter. HoLL was performed with small diameter semirigid and flexible ureteroscopes, 220 or 365 nm flexible laser fibers and a holmium:YAG laser at a power of 5-15 W (0.5-1.0 J, 10- 15 Hz). 47 of 63 patients (74.6 percent) were immediately free of stones, and 8 others (12.6 percent) lost their residual fragments spontaneously within two weeks. Another 2 patients received additional chmolitholysis for uric acid stone fragments, i.e. 90.5 percent of patients were stone free by one sitting of ureterscopic HoLL. Of the remaining 6 patients (9.5 percent) who still had residual calculi 4 weeks after HoLL, 2 asymptomatic patients refused any additional treatment, 2 patients preferred treatment with ESWL, and 2 patients had a successful second HoLL, thereby raising the success rate of ureteroscopic HoLL to 93.7 percent. 2 patients showed contrast medium extravasation on retrograde ureterograms, due to guide wire perforation. No ureteral stricture occurred. In conclusion, transurethral ureteroscopic HoLL proved to be a safe and successful minimal invasive treatment of ureteral calculi.

  3. Successful Treatment of Stent Knot in the Proximal Ureter Using Ureteroscopy and Holmium Laser

    Masters M. Richards

    2011-01-01

    Full Text Available Knotted ureteral stent is rare yet tedious complication that might represent a treatment challenge to the endourologist. Only twelve cases of knotted stent have been reported. Different management options have been reported, including simple traction, ureteroscopy, percutaneous removal, and open surgery. In this paper, we present the successful untying of the knot using ureteroscopy with holmium laser.

  4. [Comparison of validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy].

    Bi, Sheng; Xia, Ming

    2015-08-11

    To compare the validity and safety between holmium: YAG laser and traditional surgery in partial nephrectomy. A total of 28 patients were divided into two groups (holmium: YAG laser group without renal artery clamping and traditional surgery group with renal artery clamping). The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were recorded. The intraoperative blood loss, total operative time, renal artery clamping time, postoperative hospital stay, separated renal function, postoperative complications and depth of tissue injury were 80 ml, 77 min, 0 min, 7.4 days, 35 ml/min, 0, 0.9 cm, respectively, in holmium: YAG laser group. And in traditional surgery group were 69 ml, 111 min, 25.5 min, 7.3 days, 34 ml/min, 0, 2.0 cm, respectively. The differences of total operative time, renal artery clamping time and depth of tissue injury between two groups were statistically significant. The others were not statistically significant. Holmium: YAG laser is effective and safe in partial nephrectomy. It can decrease the total operative time, minimize the warm ischemia time and enlarge the extent of surgical excision.

  5. Comparison of ESWL and ureteroscopic holmium laser lithotripsy in management of ureteral stones.

    Cui, Yon; Cao, Wenzhou; Shen, Hua; Xie, Jianjun; Adams, Tamara S; Zhang, Yuanyuan; Shao, Qiang

    2014-01-01

    There are many options for urologists to treat ureteral stones that range from 8 mm to 15 mm, including ESWL and ureteroscopic holmium laser lithotripsy. While both ESWL and ureteroscopy are effective and minimally invasive procedures, there is still controversy over which one is more suitable for ureteral stones. To perform a retrospective study to compare the efficiency, safety and complications using ESWL vs. ureteroscopic holmium laser lithotripsy in management of ureteral stones. Between October 2010 and October 2012, 160 patients who underwent ESWL or ureteroscopic holmium laser lithotripsy at Suzhou municipal hospital for a single radiopaque ureteral stone (the size 8-15 mm) were evaluated. All patients were followed up with ultrasonography for six months. Stone clearance rate, costs and complications were compared. Similarity in stone clearance rate and treatment time between the two procedures; overall procedural time, analgesia requirement and total cost were significantly different. Renal colic and gross hematuria were more frequent with ESWL while voiding symptoms were more frequent with ureteroscopy. Both procedures used for ureteral stones ranging from 8 to 15 mm were safe and minimally invasive. ESWL remains first line therapy for proximal ureteral stones while ureteroscopic holmium laser lithotripsy costs more. To determining which one is preferable depends on not only stone characteristics but also patient acceptance and cost-effectiveness ratio.

  6. Comparison of ESWL and ureteroscopic holmium laser lithotripsy in management of ureteral stones.

    Yon Cui

    Full Text Available BACKGROUND: There are many options for urologists to treat ureteral stones that range from 8 mm to 15 mm, including ESWL and ureteroscopic holmium laser lithotripsy. While both ESWL and ureteroscopy are effective and minimally invasive procedures, there is still controversy over which one is more suitable for ureteral stones. OBJECTIVE: To perform a retrospective study to compare the efficiency, safety and complications using ESWL vs. ureteroscopic holmium laser lithotripsy in management of ureteral stones. METHODS: Between October 2010 and October 2012, 160 patients who underwent ESWL or ureteroscopic holmium laser lithotripsy at Suzhou municipal hospital for a single radiopaque ureteral stone (the size 8-15 mm were evaluated. All patients were followed up with ultrasonography for six months. Stone clearance rate, costs and complications were compared. RESULTS: Similarity in stone clearance rate and treatment time between the two procedures; overall procedural time, analgesia requirement and total cost were significantly different. Renal colic and gross hematuria were more frequent with ESWL while voiding symptoms were more frequent with ureteroscopy. Both procedures used for ureteral stones ranging from 8 to 15 mm were safe and minimally invasive. CONCLUSION: ESWL remains first line therapy for proximal ureteral stones while ureteroscopic holmium laser lithotripsy costs more. To determining which one is preferable depends on not only stone characteristics but also patient acceptance and cost-effectiveness ratio.

  7. Wound repair in rat urinary bladder following electrocautery or holmium laser incision

    Venzi, Giordano; Schmidlin, Franz R.; Gabbiani, Giulio; Delacretaz, Guy P.; Pittet, Brigitte; Leisinger, Hans-Juerg; Iselin, Christoph E.

    1999-06-01

    Woundhealing is a complex phenomenon which varies according the type of tissue but is also depending from the type of tissue injury. Electrocautery mainly induces coagulation necrosis while thermal damages induced by the Holmium laser primarily lead to tissue vaporization which may induce less tissue injury. The aim of this study was to evaluate the healing process of the Holmium laser induced lesions compared to electrocautery induced lesions in urothelial tissue by assessing the inflammatory response and myofibroblast behavior in sequential healing phases. A surgical wound was created in the urinary rat bladder of 32 rats either by electrocautery or by laser (N=16). The inflammatory response, the total lesion depth and the myofibroblast activity during woundhealing was then analyzed on a qualitative basis on days 0/2/4/8. The overall inflammatory response was comparable in both groups up to days two and four. However, at day eight less cellular inflammatory reaction and less myofibroblast activity was found in the specimen of lesions created by the Holmium laser. These results suggest that wound repair may be a less invasive process after Holmium laser than electrocautery.

  8. Performance and safety of holmium: YAG laser optical fibers.

    Knudsen, Bodo E; Glickman, Randolph D; Stallman, Kenneth J; Maswadi, Saher; Chew, Ben H; Beiko, Darren T; Denstedt, John D; Teichman, Joel M H

    2005-11-01

    Lower-pole ureteronephroscopy requires transmission of holmium:YAG energy along a deflected fiber. Current ureteroscopes are capable of high degrees of deflection, which may stress laser fibers beyond safe limits during lower-pole use. We hypothesized that optical fiber and safety measures differ among manufacturers. Small (200-273-microm) and medium-diameter (300-400-microm) Ho:YAG fibers were tested in a straight and 180 degrees bent configuration. Energy transmission was measured by an energy detector. Fiber durability was assessed by firing the laser in sequentially tighter bending diameters. The fibers were bent to 180 degrees with a diameter of 6 cm and run at 200- to 4000-mJ pulse energy to determine the minimum energy required to fracture the fiber. The bending diameter was decreased by 1-cm increments and testing repeated until a bending diameter of 1 cm was reached. The maximum deflection of the ACMI DUR-8E ureteroscope with each fiber in the working channel was recorded. The flow rate through the working channel of the DUR-8E was measured for each fiber. The mean energy transmission differed among fibers (P < 0.001). The Lumenis SL 200 and the InnovaQuartz 400 were the best small and medium-diameter fibers, respectively, in resisting thermal breakdown (P < 0.01). The Dornier Lightguide Super 200 fractured repeatedly at a bend diameter of 2 cm and with the lowest energy (200 mJ). The other small fibers fractured only at a bend diameter of 1 cm. The Sharplan 200 and InnovaQuartz Sureflex 273T were the most flexible fibers, the Lumenis SL 365 the least. The flow rate was inversely proportional to four times the power of the diameter of the fiber. Optical performance and safety differ among fibers. Fibers transmit various amounts of energy to their cladding when bent. During lower-pole nephroscopy with the fiber deflected, there is a risk of fiber fracture from thermal breakdown and laser-energy transmission to the endoscope. Some available laser fibers

  9. Fine- and hyperfine structure investigations of the even-parity configuration system of the atomic holmium

    Stefanska, D.; Ruczkowski, J.; Elantkowska, M.; Furmann, B.

    2018-04-01

    In this work new experimental results concerning the hyperfine structure (hfs) for the even-parity level system of the holmium atom (Ho I) were obtained; additionally, hfs data obtained recently as a by-product in investigations of the odd-parity level system were summarized. In the present work the values of the magnetic dipole and the electric quadrupole hfs constants A and B were determined for 24 even-parity levels, for 14 of them for the first time. On the basis of these results, as well as on available literature data, a parametric study of the fine structure and the hyperfine structure for the even-parity configurations of atomic holmium was performed. A multi-configuration fit of 7 configurations was carried out, taking into account second-order of the perturbation theory. For unknown electronic levels predicted values of the level energies and hfs constants are given, which can facilitate further experimental investigations.

  10. Calcium phosphate holmium-166 ceramic to addition in bone cement: synthesis and characterization

    Donanzam, Blanda A.; Campos, Tarcisio P.R., E-mail: campos@nuclear.ufmg.b [Universidade do Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Escola de Engenharia. Dept. de Engenharia Nuclear; Dalmazio, Ilza; Valente, Eduardo S., E-mail: id@cdtn.b, E-mail: valente@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Spine metastases are a common and painful complication of cancer. The treatment often consists of bone cement injection (vertebroplasty or kyphoplasty) within vertebral body for vertebrae stabilization, followed by external beam radiation therapy. Recently, researchers introduced the concept of radioactive bone cement for spine tumors therapy. Then, investigations about bioactive and radioactive materials became interesting. In this study, we present the synthesis of calcium phosphate incorporated holmium (CaP-Ho) via sol-gel technique, and its characterization by XRD, FT-IR, NA and SEM. Results showed a multiphasic bioceramic composed mainly of hydroxyapatite, {beta}-tricalcium phosphate, holmium phosphate and traces of calcium pyrophosphate. Furthermore, the nuclide Ho-166 was the major radioisotope produced. Despite that, the radioactive bioceramic CaP-{sup 166}Ho must be investigated in clinical trials to assure its efficacy and safety on spine tumors treatment (author)

  11. Calcium phosphate holmium-166 ceramic to addition in bone cement: synthesis and characterization

    Donanzam, Blanda A.; Campos, Tarcisio P.R.

    2011-01-01

    Spine metastases are a common and painful complication of cancer. The treatment often consists of bone cement injection (vertebroplasty or kyphoplasty) within vertebral body for vertebrae stabilization, followed by external beam radiation therapy. Recently, researchers introduced the concept of radioactive bone cement for spine tumors therapy. Then, investigations about bioactive and radioactive materials became interesting. In this study, we present the synthesis of calcium phosphate incorporated holmium (CaP-Ho) via sol-gel technique, and its characterization by XRD, FT-IR, NA and SEM. Results showed a multiphasic bioceramic composed mainly of hydroxyapatite, β-tricalcium phosphate, holmium phosphate and traces of calcium pyrophosphate. Furthermore, the nuclide Ho-166 was the major radioisotope produced. Despite that, the radioactive bioceramic CaP- 166 Ho must be investigated in clinical trials to assure its efficacy and safety on spine tumors treatment (author)

  12. Safety of holmium laser prostatectomy in patients with cardiac pacemaker implant

    Narmada P Gupta

    2006-01-01

    Full Text Available Objectives: The use of the standard monopolar electrocautery is associated with significant risks of implant malfunction in patients on a cardiac pacemaker. It is also associated with a risk of adverse cardiac events due to blood loss and fluid absorption. The properties of the holmium laser prevent the occurrence of these adverse events. We report the successful use of this technology in resecting the gland in patients on a permanent cardiac pacemaker implant. MATERIALS AND Methods: Six patients with permanent cardiac pacemaker implant were treated with holmium laser resection of prostate over a period of two years. Treated patients had bothersome prostatic symptoms and failed to respond to medical therapy. All patients were operated under spinal anesthesia using a high power VersaPulse ® PowerSuiteTM Holmium laser source. Normal saline was used as irrigant. Intravesical tissue morcellator was also used to remove the larger fragments in two of the patients. Results : Median patient age was 60 years (range 56-73 and median prostate volume was 40cc (range 20-48cc. None of the patient required blood transfusion or had significant hyponatremia or Transurethral resection syndrome. No patients had any pacemaker malfunction or hemodynamic instability during the procedure or in immediate postoperative period. Improvement in maximum urine flow rate was observed from an average of 7 ml/sec in preoperative period to 22 ml/sec postoperatively at 3 month followup. Conclusions: Holmium laser prostatectomy offers the ideal modality of surgery in patients on a cardiac pacemaker. It helps to avoid additional preparation and minimizes the risk of device malfunction and adverse post operative events.

  13. A holmium(III)-based single-molecule magnet with pentagonal-bipyramidal geometry

    Kajiwara, Takashi [Department of Chemistry, Faculty of Science, Nara Women' s University (Japan)

    2017-09-11

    The right environment: The remarkable properties of a recently reported holmium(III)-based single-ion magnet have been ascribed to the hyperfine interactions with the half-integer nuclear spin in combination with the pentagonal-bipyramidal coordination environment. These results provide insight into the complicated magnetic properties of nanosized magnetic materials. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  14. Material science as basis for nuclear medicine: Holmium irradiation for radioisotopes production

    Usman, Ahmed Rufai; Khandaker, Mayeen Uddin; Haba, Hiromitsu; Otuka, Naohiko

    2018-05-01

    Material Science, being an interdisciplinary field, plays important roles in nuclear science. These applications are seen in weaponry, armoured vehicles, accelerator structure and development, semiconductor detectors, nuclear medicine and many more. Present study presents the applications of some metals in nuclear medicine (radioisotope production). The charged-particle-induced nuclear reactions by using cyclotrons or accelerators have become a very vital feature of the modern nuclear medicine. Realising the importance of excitation functions for the efficient production of medical radionuclides, some very high purity holmium metals are generally prepared or purchased for bombardment in nuclear accelerators. In the present work, various methods to obtain pure holmium for radioisotope production have been discussed while also presenting details of our present studies. From the experimental work of the present studies, some very high purity holmium foils have been used in the work for a comprehensive study of residual radionuclides production cross-sections. The study was performed using a stacked-foil activation technique combined with γ-ray spectrometry. The stack was bombarded with 50.4 MeV alpha particle beam from AVF cyclotron of RI Beam Factory, Nishina Centre for Accelerator-Based Science, RIKEN, Japan. The work produced thulium radionuclides useful in nuclear medicine.

  15. Holmium:YAG laser effects on articular cartilage metabolism: in vitro

    Smith, R. Lane; Montgomery, L.; Fanton, G.; Dillingham, M.; Schurman, D. J.

    1994-09-01

    We report effects of applying variable doses of Holmium:YAG laser energy to bovine articular cartilage in vitro. The response of the cartilage to the Holmium:YAG laser energy was determined by quantification of cell proliferation and extracellular matrix glycosaminoglycan synthesis. This study demonstrates that articular cartilage cell metabolism was maintained at a normal level following treatment of cartilage at a dose of 0.6 joules/pulse. The laser energy was applied at 10 Hz for 10 seconds at 1 mm distance from the cartilage. Under these conditions and at a dose of 0.6 joules/pulse, the total energy density was calculated to be 240 joules/cm2, assuming minimal loss of energy due to water absorption. Energy levels grater than 0.8 joules/pulse corresponding to calculated energy densities greater than 320 joules/cm2 proved harmful to cartilage. Our data demonstrate that low levels of Holmium:YAG laser energy can be applied to articular cartilage under conditions that maintain and/or stimulate cell metabolism.

  16. Carbon monoxide, smoking, and atherosclerosis

    Astrup, P

    1973-10-01

    Studies on the effects of carbon monoxide and smoking on atherosclerosis are reviewed. Nonsmokers do not run the risk of getting significantly elevated carboxyhemoglobin levels from automobile exhaust in the streets, however, they do run the risk of getting elevated carboxyhemoglobin levels from exposure to CO in closed areas such as garages and tunnels. Carboxyhemoglobin levels up to 20 percent may also be found in smokers. The central nervous system seems to be influenced by carboxyhemoglobin concentrations up to 20 percent. The myocardium may also be affected. Experimental work with rabbits exposed to carbon monoxide and cholesterol is described which proved that CO has a damaging effect on arterial walls, leading to increased permeability for various plasma components, to the formation of subendothelial edema, and to increased atheromatosis. The results indicate that the much higher risk of smokers of developing arterial disease in comparison to nonsmokers is mainly due to the inhaled CO in the tobacco smoke and not to nicotine. (Air Pollut. Abstr.)

  17. Catalytic hydrogenation of carbon monoxide

    Wayland, B.B.

    1993-12-01

    Focus of this project is on developing new approaches for hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. The strategies to accomplish CO reduction are based on favorable thermodynamics manifested by rhodium macrocycles for producing a series of intermediates implicated in the catalytic hydrogenation of CO. Metalloformyl complexes from reactions of H 2 and CO, and CO reductive coupling to form metallo α-diketone species provide alternate routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics are promising candidates for future development

  18. Delayed encephalopathy after acute carbon monoxide poisoning

    Mehmet İbrahim Turan

    2014-03-01

    Full Text Available Carbon monoxide poisoning is a major cause of death following attempted suicide and accidental exposures. Although clinical presentation depends on the duration and the intensity of exposure, the assessment of the severity of intoxication is difficult. A small percentage of patients who show complete initial recovery may develop delayed neurological deficits. Delayed encephalopathy after acute carbon monoxide poisoning is a rare and poor prognosis neurologic disorders and there is no specific treatment. We present a case with early onset of delayed encephalopathy after acute carbon monoxide poisoning with typical cranial imaging findings in a child with atypical history and clinical presentation.

  19. Inhibition of photosynthesis by carbon monoxide and suspension of the carbon monoxide inhibition by light

    Gewitz, H S; Voelker, W

    1963-08-01

    The experimental subject was the autotroph Chlorella pyrenoidosa. It was found that growth conditions determine whether the alga is inhibited by carbon monoxide or not. Respiration and photosynthesis are inhibited by carbon monoxide if the cells have grown rapidly under high light intensities. The inhibition of respiration and photosynthesis found in such cells is completely reversible. The inhibition depends not only on carbon monoxide pressure, but also on the oxygen pressure prevailing at the same time. 5 references, 1 figure, 3 tables.

  20. Protect Yourself from Carbon Monoxide Poisoning

    2007-11-20

    Learn about carbon monoxide - a colorless, odorless gas - and how to protect yourself and your family.  Created: 11/20/2007 by CDC National Center for Environmental Health.   Date Released: 12/4/2007.

  1. Polyketones as alternating copolymers of carbon monoxide

    Belov, Gennady P; Novikova, Elena V

    2004-01-01

    Characteristic features of the catalytic synthesis of alternating copolymers of carbon monoxide with various olefins, dienes, styrene and its derivatives are considered. The diversity of catalyst systems used for the copolymerisation of carbon monoxide is demonstrated and their influence on the structure and the molecular mass of the resulting copolymers is analysed. The data on the structure and physicochemical and mechanical properties of this new generation of functional copolymers are generalised and described systematically for the first time.

  2. Hearing Loss due to Carbon Monoxide Poisoning

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker...... after an acute exposure to carbon monoxide. This complication was diagnosed by pure-tone audiometry and confirmed by transient evoked otoacoustic emissions. Hearing loss has not improved after 3 months of followup....

  3. Hyperfine structure investigations for the odd-parity configuration system in atomic holmium

    Stefanska, D.; Furmann, B.

    2018-02-01

    In this work new experimental results of the hyperfine structure (hfs) in the holmium atom are reported, concerning the odd-parity level system. Investigations were performed by the method of laser induced fluorescence in a hollow cathode discharge lamp on 97 spectral lines in the visible part of the spectrum. Hyperfine structure constants: magnetic dipole - A and electric quadrupole - B for 40 levels were determined for the first time; for another 21 levels the hfs constants available in the literature were remeasured. Results for the A constants can be viewed as fully reliable; for B constants further possibilities of improving the accuracy are considered.

  4. Magnetic x-ray scattering studies of holmium using synchro- tron radiation

    Gibbs, D.; Moncton, D.E.; D'Amico, K.L.; Bohr, J.; Grier, B.H.

    1985-01-01

    We present the results of magnetic x-ray scattering experiments on the rare-earth metal holmium using synchrotron radiation. Direct high-resolution measurements of the nominally incommensurate magnetic satellite reflections reveal new lock-in behavior which we explain within a simple spin-discommensuration model. As a result of magnetoelastic coupling, the spin-discommensuration array produces additional x-ray diffraction satellites. Their observation further substantiates the model and demonstrates additional advantages of synchrotron radiation for magnetic-structure studies

  5. Diode-Pumped Thulium (Tm)/Holmium (Ho) Composite Fiber 2.1-Micrometers Laser

    2015-09-01

    Schematic of the 800-nm diode pumped Tm/Ho composite fiber laser 8 Under quasi-continuous wave (Q- CW ) pumping conditions of 1-ms duration and a...Fig. 9 (Top) Schematic of the 800-nm diode -pumped Tm/Ho composite fiber laser with outcoupler. (Left) Q- CW laser performance of the Tm/Ho composite...ARL-TR-7452 ● SEP 2015 US Army Research Laboratory Diode -Pumped Thulium (Tm)/Holmium (Ho) Composite Fiber 2.1-μm Laser by G

  6. Holmium Laser Enucleation of the Prostate and Iatrogenic Arteriovenous Fistula Treated by Superselective Arterial Embolization

    Anastasios D. Asimakopoulos

    2016-01-01

    Full Text Available Iatrogenic pelvic pseudoaneurysm with concomitant arteriovenous fistula has been described as a rare and challenging complication, which may occur during transurethral resection of the prostate. We provide the first report of this complication after holmium laser enucleation of the prostate for the treatment of benign prostatic hyperplasia. The attempt to control the bleeding by conversion to open surgery and placement of haemostatic stitches into the prostatic fossa failed. Angiography with superselective arterial embolization proved to be a modern, quick, safe, and efficient treatment of this uncommon complication.

  7. Evaluation of samarium-153 and holmium-166-EDTMP in the normal baboon model

    Louw, W.K.A.; Dormehl, I.C.; Rensburg, A.J. van; Hugo, N.; Alberts, A.S.; Forsyth, O.E.; Beverley, G.; Sweetlove, M.A.; Marais, J.; Loetter, M.G.; Aswegen, A. van

    1996-11-01

    Bone-seeking radiopharmaceuticals such as ethylenediaminetetramethylene phosphonate (EDTMP) complexes of samarium-153 and holmium-166 are receiving considerable attention for therapeutic treatment of bone metastases. In this study, using the baboon experimental model, multicompartmental analysis revealed that with regard to pharmacokinetics, biodistribution, and skeletal localisation, {sup 166}Ho-EDTMP was significantly inferior to {sup 153}Sm-EDTMP and {sup 99m}Tc-MDP. A more suitable {sup 166}Ho-bone-seeking agent should thus be sought for closer similarity to {sup 153}Sm-EDTMP to exploit fully the therapeutic potential of its shorter half-life and more energetic beta radiation.

  8. Lumbar endoscopic percutaneous discolisis, with Holmium YAG laser - four years of experience

    Ramirez L, Jorge Felipe; Rugeles O, Jose G

    2001-01-01

    we have designed a prospective study over 220 patients with lumbar hernia. our purpose is to show the results that we have obtained with endoscopic percutaneous holmium YAG laser lumbar disc decompression. In all cases, ambulatory surgery was performed using local anesthesia, follow up based on Mac Nab criteria was made with excellent and good results in 75% of patients this is a useful safety outpatient procedure with good results, fewer complications, reduced costs and with the same or better results than traditional procedures

  9. Specific heat of holmium and YNi2B2C. Criticalbehaviour and superconducting properties

    Bekkali, Abdelhakim

    2010-01-01

    Object of the thesis is the study of the specific heat of holmium and YNi 2 B 2 C in the temperature ranges from 50 to 200 KI respectively from 380 mK to 20 K in magnetic fields up to 9 T. In the present thesis the criticalbehaviour of YNi 2 B 2 C and properties of the superconducting state of tne non-magnetic rare-earth nickel borocarbide YNi 2 B 2 C are studied by means of a self-developed measurement apparatur of the specific heat using the quasi-adiabatic heating-pulse method as well as of holmium by means of the relaxation method. In this thesis reliable statements about the critical exponents on monocrystalline holmium could be made. The study on holmium proves that the critical behaviour of the specific heats cannot be described in the framework of the predictions of the chiral universality classes. By means of measurements of the specific heat in this thesis could be confirmed that YNi 2 B 2 C is a multiband superconductor. The positive curvature of the boundary line below T c in the phase diagram yields a first hint to the many-band character of YNI 2 B 2 C. In the zero-field the electronic specific heat in the superconducting state c es (T) can be not explained in the framework of the pure BCS theory. At low temperatures a residual contribution by normally conducting electrons could be detected, which hints to a not completely opened energy gap. A possible explanation would be that a band (or several bands) with low charge-carrier concentration not contribute to the superconductivity. This result agrees with de Haas-van Alphen measurements on isostructural superconducting LuNi 2 B 2 C monocrystals, which suggest the many-band character of the superconductivity as well as a vanishing energy gap in one band. The fluctuation behaviour of the specific heat of YNi 2 B 2 C in the neighbourhood of the superconducting-normally conducting transition agrees well with that of the 3D-XY model. [de

  10. Endoscopic removal of a proximal urethral stent using a holmium laser: Case report and literature review

    Francisco Botelho

    2012-01-01

    Full Text Available Urethral stents were initially developed for the management of urethral strictures and obstructive voiding disorders in select patients. Urethral stent complications are common and may require stent explantation, which is often quite challenging. We present our experience with endoscopic removal of an encrusted UroLume proximal urethral stent in a 72-year-old male using a holmium laser. The literature on various management options and outcomes for urethral stent removal is reviewed. Endoscopic removal of proximal urethral stents is feasible and safe and should be considered as the primary treatment option in patients requiring stent extraction.

  11. Evidence for a devil's staircase in holmium produced by an applied magnetic field

    Cowley, R.A.; Jehan, D.A.; McMorrow, D.F.; McIntyre, G.J.

    1991-01-01

    The magnetic structure of holmium has been studied using neutron diffraction when a magnetic field is applied along the c axis. The field has the effect of suppressing the onset of the commensurate cone phase found at low temperatures in zero field, and instead produces a series of spin-slip structures. In contrast to the zero-field diffraction experiments, where a continuous variation of the magnetic wave vector q was observed, we find that below ∼15 K the wave vector q is always commensurate and forms a devil's staircase with increasing field

  12. An unusual case of carbon monoxide poisoning.

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-01-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem. Images Figure 1 Figure 2 PMID:10379009

  13. An unusual case of carbon monoxide poisoning.

    Auger, P L; Levesque, B; Martel, R; Prud'homme, H; Bellemare, D; Barbeau, C; Lachance, P; Rhainds, M

    1999-07-01

    Carbon monoxide, a gas originating from incomplete combustion of carbon-based fuels, is an important cause of human deaths. In this paper, we describe an unusual carbon monoxide poisoning in a dwelling without obvious sources of combustion gases, for which two adults had to be treated in a hyperbaric chamber. Carbon monoxide readings were taken in the house and in the neighboring homes. Methane gas and nitrogen oxide levels were also monitored in the house air. Soil samples were collected around the house and tested for hydrocarbon residues. The investigation revealed the presence of a pocket of carbon monoxide under the foundation of the house. The first readings revealed carbon monoxide levels of 500 ppm in the basement. The contamination lasted for a week. The investigation indicated that the probable source of contamination was the use of explosives at a nearby rain sewer construction site. The use of explosives in a residential area can constitute a major source of carbon monoxide for the neighboring populations. This must be investigated, and public health authorities, primary-care physicians, governmental authorities, and users and manufacturers of explosives must be made aware of this problem.

  14. Electrocatalytic oxidation of carbon monoxide

    Manuel de Jesus Santiago Farias

    2009-01-01

    Full Text Available Este trabalho discute alguns aspectos importantes relacionados à reação de eletrooxidação do monóxido de carbono sobre monocristais de platina, em meio ácido. Aspectos mecanísticos são discutidos em termos da formação das estruturas compactas que o CO forma quando este é adsorvido. As principais idéias aqui apresentadas, levam em consideração as existências dessas estruturas. Os clássicos mecanismos Lagmuir-Hinshelwood e Eley-Rideal são aqui discutidos, especialmente o primeiro considerando a mobilidade do CO e também a nucleação e crescimento de ilhas formadas por espécies adsorvidas contendo oxigênio.////////// This work discusses some important aspects related to the carbon monoxide electrooxidation reaction on Pt single crystal electrodes in acidic media. The mechanistic aspects are discussed in terms of the formation of compact structures developed when CO is adsorbed. The main ideas presented here are focused on the mechanistic aspects that take into account the existence of such structures. The classical kinetic mechanisms of Lagmuir-Hinshelwood and Eley-Rideal are discussed considering the superficial mobility of CO or nucleation-growing of islands formed by oxygen-containing adsorbates.

  15. Evaluation of holmium laser versus cold knife in optical internal urethrotomy for the management of short segment urethral stricture.

    Jain, Sudhir Kumar; Kaza, Ram Chandra Murthy; Singh, Bipin Kumar

    2014-10-01

    SACHSE COLD KNIFE IS CONVENTIONALLY USED FOR OPTICAL INTERNAL URETHROTOMY INTENDED TO MANAGE URETHRAL STRICTURES AND HO: YAG laser is an alternative to it. The aim of this study was to evaluate the role of urethral stricture treatment outcomes, efficacy, and complications using cold knife and Ho: YAG (Holmium laser) for optical internal urethrotomy. In this prospective study included, 90 male patients age >18 years, with diagnosis of urethral stricture admitted for internal optical urethrotomy during April 2010 to March 2012. The patients were randomized into two groups containing 45 patients each using computer generated random number. In group A (Holmium group), internal urethrotomy was done with Holmium laser and in group B (Cold knife group) Sachse cold knife was used. Patients were followed up for 6 months after surgery in Out Patient Department on 15, 30 and 180 post-operative days. At each follow up visit physical examination, and uroflowmetry was performed along with noting complaints, if any. The peak flow rates (PFR) were compared between the two groups on each follow up. At 180 days (6 month interval) the difference between mean of PFR for Holmium and Cold knife group was statistically highly significant (P knife urethrotomy.

  16. Use of the Moses Technology to Improve Holmium Laser Lithotripsy Outcomes: A Preclinical Study.

    Elhilali, Mostafa M; Badaan, Shadie; Ibrahim, Ahmed; Andonian, Sero

    2017-06-01

    To evaluate in vitro and in vivo effects of Moses technology in Holmium laser and to compare it with the Regular mode in terms of lithotripsy efficiency and laser-tissue interactions. The Lumenis ® Pulse™ P120H holmium laser system together with Moses D/F/L fibers were used to compare the Regular mode with the Moses modes in stone retropulsion by using a high-speed camera, and stone ablation efficiency. In addition, a porcine ureteroscopy model was used to assess stone fragmentation and dusting as well as laser-tissue interaction with the ureteral wall. After a laser pulse, in vitro stone displacement experiments showed a significant reduction in retropulsion when using the Moses mode. The stone movement was reduced by 50 times at 0.8 J and 10 Hz (p technology resulted in more efficient laser lithotripsy, in addition to significantly reduced stone retropulsion, and displayed a margin of safety that may result in a shorter procedural time and safer lithotripsy.

  17. Laparoscopy-assisted micropercutaneous choledocholithotripsy with holmium laser in a cholecystectomized patient: an initial report.

    Gökçen, Kaan; Atabey, Mustafa; Gökçen, Pınar; Gökçe, Gökhan

    2017-12-01

    We present a novel minimally invasive technique, laparoscopy-assisted micropercutaneous choledocholithotripsy, for choledocholithiasis that cannot be treated with other endoscopic techniques. This technique includes standard laparoscopic exploration of the common bile duct, combined with an all-seeing needle and holmium laser lithotripsy. As is known, an all-seeing needle is used in micropercutaneous nephrolithotomy for middle-sized renal stones. In this technique, an all-seeing needle was inserted into the dilatated common bile duct under laparoscopic vision and then a lithotripsy procedure was performed with a holmium laser behind the biliary stent. A cholecystectomized female patient with a 21-mm stone in the common bile duct who previously underwent an unsuccessful endoscopic retrograde cholangiopancreatography procedure was operated on in our service with laparoscopy-assisted micropercutaneous choledocholithotomy without a T-tube. This novel procedure was completed uneventfully and the patient was discharged without any complications. In the future, this procedure will hopefully be a treatment modality in choledocholithiasis that cannot be treated by other minimally invasive techniques.

  18. Catalytic hydrogenation of carbon monoxide

    Wayland, B.B.

    1992-12-01

    This project is focused on developing strategies to accomplish the reduction and hydrogenation of carbon monoxide to produce organic oxygenates at mild conditions. Our approaches to this issue are based on the recognition that rhodium macrocycles have unusually favorable thermodynamic values for producing a series of intermediate implicated in the catalytic hydrogenation of CO. Observations of metalloformyl complexes produced by reactions of H{sub 2} and CO, and reductive coupling of CO to form metallo {alpha}-diketone species have suggested a multiplicity of routes to organic oxygenates that utilize these species as intermediates. Thermodynamic and kinetic-mechanistic studies are used in constructing energy profiles for a variety of potential pathways, and these schemes are used in guiding the design of new metallospecies to improve the thermodynamic and kinetic factors for individual steps in the overall process. Variation of the electronic and steric effects associated with the ligand arrays along with the influences of the reaction medium provide the chemical tools for tuning these factors. Emerging knowledge of the factors that contribute to M-H, M-C and M-O bond enthalpies is directing the search for ligand arrays that will expand the range of metal species that have favorable thermodynamic parameters to produce the primary intermediates for CO hydrogenation. Studies of rhodium complexes are being extended to non-macrocyclic ligand complexes that emulate the favorable thermodynamic features associated with rhodium macrocycles, but that also manifest improved reaction kinetics. Multifunctional catalyst systems designed to couple the ability of rhodium complexes to produce formyl and diketone intermediates with a second catalyst that hydrogenates these imtermediates are promising approaches to accomplish CO hydrogenation at mild conditions.

  19. Enzymic oxidation of carbon monoxide. II

    Yagi, T

    1959-01-01

    An enzyme which catalyzes the oxidation of carbon monoxide into carbon dioxide was obtained in a cell free state from Desulfovibrio desulfuricans. The enzyme activity was assayed manometrically by measuring the rate of gas uptake under the atmosphere of carbon monoxide in the presence of benzyl-viologen as an oxidant. The optimum pH range was 7 to 8. The activity was slightly suppressed by illumination. The enzyme was more stable than hydrogenase or formate dehydrogenase against the heat treatment, suggesting that it is a different entity from these enzymes. In the absence of an added oxidant, the enzyme preparation produced hydrogen gas under the atmosphere of carbon monoxide. The phenomenon can be explained assuming the reductive decomposition of water. 17 references, 4 figures, 2 tables.

  20. Effect of vegetation in reducing carbon monoxide

    Kimura, J C

    1977-01-01

    Carbon monoxide is a product of incomplete combustion. Because almost all of this gas is produced by motor vehicles, it is considered to have a line rather than a stationary point source. Greatest concentrations of this lethal gas correspond to periods of peak traffic volume and congestion; therefore, there are two daily periods of maxima and minima. Carbon monoxide cannot be detected by sight or smell. For this reason, this gas is especially deadly. During the summer of 1975, a study involving carbon monoxide concentrations at selected sites in Sendai was undertaken in conjunction with an ongoing investigation of urban pollution under the directorship of Professor Toshio Noh of Tohoku University. This study was made possible by a grant from the Japan Society for the Promotion of Science. 5 references, 5 figures, 1 table.

  1. Pulmonary edema in acute carbon monoxide poisoning

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk

    1974-01-01

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis

  2. Occupational medicine effects of carbon monoxide

    Coombs, W.M. [South African Society of Occupational Medicine (South Africa)

    1998-10-01

    Carbon monoxide can affect the body if it is inhaled or if liquid carbon monoxide comes in contact with the eyes or skin. The effects of overexposure are discussed and a brief explanation of the toxicological effects of CO given. Methods of control of CO from common operations (exhaust fumes of internal combustion engines, the chemical industry and foundries, welding, mines or tunnels, fire damp explosions, industrial heating) are by local exhaust ventilation or use of a respiratory protective device. The South African hazardous chemical substance regulation NO. R. 1179 of 25 August 1995 stipulates maximum safe levels of CO concentration. 4 refs., 1 photo.

  3. Pulmonary edema in acute carbon monoxide poisoning

    Kim, Kun Sang; Chang, Kee Hyun; Lee, Myung Uk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Acute carbon monoxide poisoning has frequently occurred in Korean, because of the coal briquette being widely used as fuel in Korean residences. Carbon monoxide poisoning has been extensively studied, but it has been sparsely reported that pulmonary edema may develop in acute CO poisoning. We have noticed nine cases of pulmonary edema in acute CO poisoning last year. Other possible causes of pulmonary edema could be exclude in all cases but one. The purpose of this paper is to describe nine cases of pulmonary edema complicated in acute CO poisoning and discuss the pathogenesis and the prognosis.

  4. 21 CFR 177.1312 - Ethylene-carbon monoxide copolymers.

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene-carbon monoxide copolymers. 177.1312... Basic Components of Single and Repeated Use Food Contact Surfaces § 177.1312 Ethylene-carbon monoxide copolymers. The ethylene-carbon monoxide copolymers identified in paragraph (a) of this section may be safely...

  5. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ...

  6. Alternative Treatment of Osteoma Using an Endoscopic Holmium-YAG Laser

    Ba Leun Han

    2012-07-01

    Full Text Available Osteoma is one of the most common tumors of the cranial vault and the facial skeleton. For osteoma in the facial region, endoscopic resection is widely used to prevent surgical scarring. Tumors in a total of 14 patients were resected using an endoscopic holmium-doped yttrium aluminium garnet (Ho:YAG laser with a long flexible fiber. Aside from having the advantage of not leaving a scar due to the use of endoscopy, this procedure allowed resection at any position, was minimally invasive, and caused less postoperative pain. This method yielded excellent cosmetic results, so the endoscopic Ho:YAG laser is expected to emerge as a good treatment option for osteoma.

  7. Lande gJ factors for even-parity electronic levels in the holmium atom

    Stefanska, D.; Werbowy, S.; Krzykowski, A.; Furmann, B.

    2018-05-01

    In this work the hyperfine structure of the Zeeman splitting for 18 even-parity levels in the holmium atom was investigated. The experimental method applied was laser induced fluorescence in a hollow cathode discharge lamp. 20 spectral lines were investigated involving odd-parity levels from the ground multiplet, for which Lande gJ factors are known with high precision, as the lower levels; this greatly facilitated the evaluation of gJ factors for the upper levels. The gJ values for the even-parity levels considered are reported for the first time. They proved to compare fairly well with the values obtained recently in a semi-empirical analysis for the even-parity level system of Ho I.

  8. Development of phosphate glass microspheres containing holmium for selective internal radiotherapy

    Barros Filho, Eraldo Cordeiro

    2016-01-01

    The selective internal radiotherapy is an alternative for some kinds of cancer as the hepatocellular carcinoma (HCC) or primary liver cancer treatment. In this treatment, glass or polymer microspheres containing radionuclides inside their structure are introduced in the liver through hepatic artery and trapped at the arterioles that feed the tumor. In this work, the development of phosphate glasses containing holmium for production of microspheres and their application in Brazil are proposed. The developed glasses presented suitable chemical durability, density of 2,7(3) g/cm 3 , high thermal stability and the impurities contained therein do not preclude the treatment. The microspheres were produced by the flame method and the gravitational fall method, and were characterized by means of several techniques to evaluate shape, average particle size, activity and biocompatibility suitable for selective internal radiotherapy. Based in the main results, the submission to in vivo tests is proposed. (author)

  9. High power operation of cladding pumped holmium-doped silica fibre lasers.

    Hemming, Alexander; Bennetts, Shayne; Simakov, Nikita; Davidson, Alan; Haub, John; Carter, Adrian

    2013-02-25

    We report the highest power operation of a resonantly cladding-pumped, holmium-doped silica fibre laser. The cladding pumped all-glass fibre utilises a fluorine doped glass layer to provide low loss cladding guidance of the 1.95 µm pump radiation. The operation of both single mode and large-mode area fibre lasers was demonstrated, with up to 140 W of output power achieved. A slope efficiency of 59% versus launched pump power was demonstrated. The free running emission was measured to be 2.12-2.15 µm demonstrating the potential of this architecture to address the long wavelength operation of silica based fibre lasers with high efficiency.

  10. Influence of crystallite size and temperature on the antiferromagnetic helices of terbium and holmium metal

    Bick, Jens-Peter; Michels, Andreas [Universitaet des Saarlandes, D-66041 Saarbruecken (Germany); University of Luxembourg, L-1511 Luxembourg (Luxembourg); Ferdinand, Adrian; Birringer, Rainer [Universitaet des Saarlandes, D-66041 Saarbruecken (Germany); Baller, Joerg; Sanctuary, Roland [University of Luxembourg, L-1511 Luxembourg (Luxembourg); Philippi, Stefan [Leibniz Institute for Solid State and Materials Research, D-01069 Dresden (Germany); Lott, Dieter [GKSS Research Center, D-21502 Geesthacht (Germany); Balog, Sandor [Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Rotenberg, Eli [Lawrence Berkeley National Laboratory, California 94720 (United States); Kaindl, Guenter [Freie Universitaet Berlin, D-14195 Berlin-Dahlem (Germany); Doebrich, Kristian M. [Freie Universitaet Berlin, D-14195 Berlin-Dahlem (Germany); Max-Born-Institut, D-12489 Berlin (Germany)

    2011-07-01

    We report on the results of grain-size and temperature-dependent magnetization, specific-heat, neutron-scattering, and angle-resolved photoelectron spectroscopy (ARPES) experiments on the heavy rare-earth metals terbium and holmium, with particular emphasis on the temperature regions where the helical antiferromagnetic phases exist. In contrast to Ho, we find that the helical structure in Tb is relative strongly affected by microstructural disorder, specifically, it can no longer be detected for the smallest studied grain size of D=18 nm. Moreover, in coarse-grained Tb a helical structure persists even in the ferromagnetic regime, down to about T=215 K, in agreement with the ARPES data, which reveal a nesting feature of the Fermi surface at the L point of the Brillouin zone at T=210 K.

  11. Holmium-doped fluorotellurite microstructured fibers for 2.1 μm lasing.

    Yao, Chuanfei; He, Chunfeng; Jia, Zhixu; Wang, Shunbin; Qin, Guanshi; Ohishi, Yasutake; Qin, Weiping

    2015-10-15

    Holmium (Ho3+)-doped fluorotellurite microstructured fibers based on TeO2-BaF2-Y2O3 glasses are fabricated by using a rod-in-tube method. By using a 1.992 μm fiber laser as the pump source, lasing at 2.077 μm is obtained from a 27 cm long Ho3+-doped fluorotellurite microstructured fiber. The maximum unsaturated power is about 161 mW and the corresponding slope efficiency is up to 67.4%. The influence of fiber length on lasing at 2.1 μm is also investigated. Our results show that Ho3+-doped fluorotellurite microstructured fibers are promising gain media for 2.1 μm laser applications.

  12. Acute and chronic response of meniscal fibrocartilage to holmium:YAG laser irradiation

    Horan, Patrick J.; Popovic, Neven A.; Islinger, Richard B.; Kuklo, Timothy R.; Dick, Edward J.

    1997-05-01

    The acute and chronic (10 week) histological effects of the holmium:YAG laser during partial meniscectomy in an in vivo rabbit model were investigated. Twenty-four adult male New Zealand rabbits underwent bilateral parapatellar medial knee arthrotomies. In the right knee, a partial medial meniscectomy was done through the avascular zone using a standard surgical blade. In the left knee, an anatomically similar partial medial meniscectomy was performed using a Ho:YAG laser (Coherent, USA). This study indicates that the laser creates two zones of damage in the meniscal fibrocartilage and that the zone of thermal change may act as a barrier to healing. The zone of thermal change which is eventually debrided was thought at the time of surgery to be viable. In the laser cut menisci, the synovium appears to have greater inflammation early and to be equivalent with the scalpel cut after three weeks. At all time periods there appeared more cellular damage in the laser specimens.

  13. Bouveret's syndrome complicated by distal gallstone ileus after laser lithotropsy using Holmium: YAG laser

    Rodgers John B

    2002-06-01

    Full Text Available Abstract Background Bouveret's syndrome is an unusual presentation of duodenal obstruction caused by the passage of a large gallstone through a cholecystoduodenal fistula. Endoscopic therapy has been used as first-line treatment, especially in patients with high surgical risk. Case presentation We report a 67-year-old woman who underwent an endoscopic attempt to fragment and retrieve a duodenal stone using a Holmium: Yttrium-Aluminum-Garnet Laser (Ho:YAG which resulted in small bowel obstruction. The patient successfully underwent enterolithotomy without cholecystectomy or closure of the fistula. Conclusion We conclude that, distal gallstone obstruction, due to migration of partially fragmented stones, can occur as a possible complication of laser lithotripsy treatment of Bouveret's syndrome and might require urgent enterolithotomy.

  14. Synthesis and optical properties of antimony oxide glasses doped with holmium trioxide

    Raghunatha, S.; Eraiah, B., E-mail: eraiah@rediffmail.com [Department of physics, Bangalore University, Bengaluru – 560 056. India (India)

    2016-05-06

    Holmium doped lithium-antimony-lead borate glasses having 1 mol% AgNO{sub 3} with composition 50B{sub 2}O{sub 3}-20PbO-25Sb{sub 2}O{sub 3}-5Li{sub 2}O have been prepared using single step melt quenching technique. The XRD spectrum confirms amorphous nature of glasses. The optical absorbance studies were carried out on these glasses. The optical direct band gap energies were found to be in the range of 3.10 eV to 3.31 eV and indirect band gap energies were found to be in the range of 2.28 eV to 3.00 eV. The refractive indexes have been calculated by using Lorentz-Lorenz formula and the calculated values in the range of 2.31 to 2.37.

  15. Hearing Loss due to Carbon Monoxide Poisoning

    Mehrparvar, Amir Houshang; Davari, Mohammad Hossein; Mollasadeghi, Abolfazl

    2013-01-01

    Carbon monoxide poisoning is one of the rare causes of hearing loss which may cause reversible or irreversible, unilateral or bilateral hearing loss after acute or chronic exposure. In this report, we present a case of bilateral sensorineural hearing loss in a secondary smelting workshop worker a...

  16. CARBON MONOXIDE AND THE NERVOUS SYSTEM

    Carbon monoxide (CO) is a colorless, tasteless, odorless, and non-irritating gas formed when carbon in fuel is not burned completely. It enters the bloodstream through the lungs and attaches to hemoglobin (Hb), the body's oxygen carrier, forming carboxyhemoglobin (COHb) and there...

  17. Study of intraarticular application of 166-Holmium IHPP in healthy hares

    Szentesi, M.; Koernyei, J.; Antalffi, M.; Toerkoe, J.; Toth, G.Y.; Janoki, G.Y.; Balogh, L.

    2002-01-01

    Radiosynoviorthesis non invasive therapy in rheumatoid arthritis is an alternative of surgical synovectomy. This method was applied first by Fellinger in 1952, and since then it has been practiced all over the world. The leakage of traditionally applied isotopes is cca. 4-10%, and the whole body dose is 10 rads. The objective of our work is to produce a nuclear medication with a minimum radioactive load, of short half-life and ideal molecule size for the treatment of radiosynoviorthesis / 166- Holmium IHPP / and the study of its effect on healthy hares. The first results have been already reported on previously. 166-Holmium IHPP has the features of: half-life of 26.9 hr, the maximum soft-tissue penetration of a beta particle 1.84 MeV, emitted from 166-Ho 8.4 mm. With an average of 3.3 mm. Methods applied: Biodistribution analysis, gamma camera analysis, biochemical and histological tests with photo- and electro microscope were carried out on healthy New Zealand hares 6, 24, 72, 168 hours after radiosynoviorthesis. Results: All the testing methods applied showed that 97 /96,1-98,2/ % remained on the spot of the injection and the 2/3 of the small percentage released leakage: is excreted by the liver and the other 1/3 of it with the urine.The hematological and biochemical parameters did not show differences. During histological examination moderate level acute radioarthritis in the knee joint treated was observed (6-24 hours after the injection), then moderate level subacute radioarthritis with slight degeneration in the synovial membrane and in the synovial fluid. It was only the electro microscopic examination that did show a minimal degeneration in the cartilage and in the menisci, but it got regenerated in 168 hours. Conclusion: The examination carried out has proved that 166-Ho -IHPP can be effectively applied in radiosynoviorthesis. Clinical testing has started

  18. Microspheres of poly(ε-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de

    2011-01-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho 2 O 3 . Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  19. Microspheres of poly({epsilon}-caprolactone) loaded Holmium-165: morphology and thermal degradation behavior

    Geraldes, Adriana Napoleao; Miyamoto, Douglas Massao; Lira, Raphael Arivar de; Osso Junior, Joao Alberto; Nascimento, Nanci; Azevedo, Mariangela de Burgos M. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Polycaprolactone (PCL), being one of the most important biocompatible and biodegradable aliphatic polyester, provides many potential biomedical. The preparation of biodegradable materials, polymer-based microspheres, is being developed by our group and the goal is to prepare and label with Ho-165 different polymer-based microspheres. The use of radionuclide-loaded microspheres is a promising treatment of liver malignancies. PCL microspheres can be loaded with holmium acetylacetonate (HoAcAc). PCL and PCL/HoAcAc microspheres were prepared by an emulsion solvent extraction/evaporation technique. The PCL/ HoAcAc microspheres were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP to radionuclide activation. Gamma irradiation was performed at 25 and 50 kGy doses. The microspheres were evaluated by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TG), Fourier transformed infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and con focal laser scanning microscopy (CLSM). In the CLSM images were observed emission in 488 nm characteristic of holmium. The SEM surface image of PCL/HoAcAc microspheres showed more roughness than PCL microspheres. TG of PCL/HoAcAc microspheres showed a substantial weight loss above 200 degree C, indicating decomposition of HoAcAc. The residual weight indicates the presence of Ho{sub 2}O{sub 3}. Gamma irradiation at 25 and 50 kGy doses had no effect on the PCL/HoAcAc microspheres, which indicates that the chemical composition of the microspheres had not change. (author)

  20. Holmium laser assisted ′anatomical′ enucleation of adenoma of benign hyperplasia of prostate

    Shivadeo S Bapat

    2006-01-01

    Full Text Available Aims: To present our technique of Holmium Laser assisted "ANATOMICAL" enucleation of the benign prostatic adenoma (HoLEP in 219 patients. Procedure is based on the principle of digital enucleation of the adenoma from its surgical capsule, but performed entirely by perurethral endoscopic technique assisted by Holmium Laser. Materials and Methods: From March 2001 to November 2004, 219 patients under went HoLEP. After the initial cuts from bladder neck to verumontanum at 5 and 7 o′clock position, capsule is identified. The beak of the resectoscope sheath was inserted in the plane between the capsule and the adenoma and the adenoma was physically pushed away towards the urethra from the capsule. Laser was used to coagulate the bleeders, to cut the mucosal attachments and tough stromal tissue. Procedure was repeated for median and two lateral lobes. There was minimal bleeding and fluid absorption. Complications were few. Results: In 206 cases successful enucleation of the adenoma was carried out. First 13 cases formed part of the learning curve and were completed by standard transurethral resection of prostate (TURP. IPSS score dropped from average of 23 to 8 and peak flow improved from 20. No patient had postoperative urinary incontinence or stricture. Conclusions: HoLEP is an effective alternative to TURP. Ultimate end results replicate the end results of open enucleation of BPH without its morbidity and have all the advantages of endoscopic surgery. It offers distinct advantages over standard TURP as the incidence of blood transfusion and fluid absorption are greatly minimized.

  1. Separation of holmium (III) from aqueous chloride medium by Amberlite IRC748

    Vijayalakshmi, R.; Anitha, M.; Singh, D.K.; Chakravartty, J.K.

    2016-01-01

    High purity holmium finds applications in nuclear reactors as control rod, rare earth based magnetic alloys, lasers, medical applications, etc. Holmium belongs to the heavier group of rare earths and its content is very less (<0.5%) in Monazite mineral, hence its recovery from various potential sources becomes essential. Ion exchange technique is a well known method for effective separation, purification, recovery, and concentration of metal ions from lean aqueous solutions. It has also been widely used for separation and purification of rare earths. In the present investigation application of Amberlite IRC748, a chelating type of resin containing iminodiacetic acid functional group for separation of Ho(III) was explored. The effects of various parameters such as pH, contact time, weight of resin, initial metal concentration and temperature on the adsorption characteristics of Ho(III) were investigated in detail. The loading of Ho(III) ion onto resin increased with increasing the initial concentration. The adsorption was strongly dependent on pH of the medium with enhanced adsorption as the pH turned from 1 to 4. In the batch system, the Amberlite IRC748 resin exhibited the highest Ho(III) ion uptake as 180 mg/g at 298 K, at an initial pH value of 4. The adsorption data gave good fit with Langmuir isotherm which was better than the Freundlich curve. The thermodynamic parameters such as ΔH, ΔS and ΔG were evaluated from the temperature variation data. Negative value of ΔH (-11.5 kJ/mole), indicated that the adsorption of Ho(III) ion onto Amberlite resin was exothermic in nature. ΔS was found to be 5.52 J/mole/K. Kinetic study indicated that the adsorption data fitted the pseudo second order kinetic equation. (author)

  2. Percutaneous Transhepatic Endoscopic Holmium Laser Lithotripsy for Intrahepatic and Choledochal Biliary Stones

    Rimon, Uri; Kleinmann, Nir; Bensaid, Paul; Golan, Gil; Garniek, Alexander; Khaitovich, Boris; Winkler, Harry

    2011-01-01

    Purpose: To report our approach for treating complicated biliary calculi by percutaneous transhepatic endoscopic biliary holmium laser lithotripsy (PTBL). Patients and Methods: Twenty-two symptomatic patients (11 men and 11 women, age range 51 to 88 years) with intrahepatic or common bile duct calculi underwent PTBL. Nine patients had undergone previous gastrectomy and small-bowel anastomosis, thus precluding endoscopic retrograde cholangiopancreatography. In the other 13 patients, stone removal attempts by ERCP failed due to failed access or very large calculi. We used a 7.5F flexible ureteroscope and a 200-μm holmium laser fiber by way of a percutaneous transhepatic tract, with graded fluoroscopy, to fragment the calculi with direct vision. Balloon dilatation was added when a stricture was seen. The procedure was performed with the patient under general anaesthesia. A biliary drainage tube was left at the end of the procedure. Results: All stones were completely fragmented and flushed into the small bowel under direct vision except for one patient in whom the procedure was aborted. In 18 patients, 1 session sufficed, and in 3 patients, 2 sessions were needed. In 7 patients, balloon dilatation was performed for benign stricture after Whipple operation (n = 3), for choledochalenteric anastomosis (n = 3), and for recurrent cholangitis (n = 1). Adjunctive “balloon push” (n = 4) and “rendezvous” (n = 1) procedures were needed to completely clean the biliary tree. None of these patients needed surgery. Conclusion: Complicated or large biliary calculi can be treated successfully using PTBL. We suggest that this approach should become the first choice of treatment before laparoscopic or open surgery is considered.

  3. Magneto-optical study of holmium iron garnet Ho3Fe5O12

    Kalashnikova, A. M.; Pavlov, V. V.; Kimel, A. V.; Kirilyuk, A.; Rasing, Th.; Pisarev, R. V.

    2012-09-01

    Bulk holmium iron garnet Ho3Fe5O12 is a cubic ferrimagnet with Curie temperature TC = 567 K and magnetization compensation point in the range 130-140 K. The magneto-optical data are presented for a holmium iron garnet Ho3Fe5O12 film, ˜10 μm thick, epitaxially grown on a (111)-type gadolinium-gallium garnet Gd3Ga5O12 substrate. A specific feature of this structure is that the parameters of the bulk material, from which the film was grown, closely match the substrate ones. The temperature and field dependences of Faraday rotation as well as the temperature dependence of the domain structure in zero field were investigated. The compensation point of the structure was found to be Tcomp = 127 K. It was shown that the temperature dependence of the characteristic size of domain structure diverges at this point. Based on the obtained results we established that the magnetic anisotropy of the material is determined by both uniaxial and cubic contributions, each characterized by different temperature dependence. A complex shape of hysteresis loops and sharp changes of the domain pattern with temperature indicate the presence of collinear-noncollinear phase transitions. Study of the optical second harmonic generation was carried out using 100 fs laser pulses with central photon energy E = 1.55 eV. The electric dipole contribution (both crystallographic and magnetic) to the second harmonic generation was observed with high reliability despite a small mismatch of the film and substrate parameters.

  4. Vacancy distribution in nonstoichiometric vanadium monoxide

    Gusev, A.I.; Davydov, D.A.; Valeeva, A.A.

    2011-01-01

    Graphical abstract: Display Omitted Research highlights: → A certain fraction of vanadium atoms in disordered cubic vanadium monoxide VO y and ordered tetragonal phase V 52 O 64 is located in tetrahedral positions of a basic cubic lattice. → These positions are never occupied by any atoms in other strongly nonstoichiometric carbides, nitrides and oxides. → Both disordered and ordered structures of vanadium monoxide are characterized by the presence of short-range order of displacements in the oxygen sublattice and short-range order of substitution in the metal sublattice. → The short-range order of displacement is caused by the local displacements of O atoms from V (t) atoms occupying tetrahedral positions. The short-range order of substitution appears because V (t) atoms in the tetrahedral positions are always in the environment of four vacancies □ of the vanadium sublattice. - Abstract: Structural vacancy distribution in the crystal lattice of the tetragonal V 52 O 64 superstructure which is formed on the basis of disordered superstoichiometric cubic vanadium monoxide VO y ≡V x O z is experimentally determined and the presence of significant local atomic displacements and large local microstrains in a crystal lattice of real ordered phase is established. It is shown that the relaxation of local microstrains takes place owing to the basic disordered cubic phase grain refinement and a formation of ordered phase domains. The ordered phase domains grow in the direction from the boundaries to the centre of grains of the disordered basic cubic phase. Isothermal evolution at 970 K of the average domain size in ordered VO 1.29 vanadium monoxide is established. It is shown that the short-range order presents in a metal sublattice of disordered cubic VO y vanadium monoxide. The character of the short-range order is such that vanadium atoms occupying tetrahedral positions are in the environment of four vacant sites of the vanadium sublattice. This means that the

  5. Carbon monoxide: The 21st century poison that goes unnoticed

    Hoskins, J.A.

    1999-01-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described

  6. Carbon monoxide: The 21st century poison that goes unnoticed

    Hoskins, J.A. [Reigate, Surrey (United Kingdom)

    1999-07-01

    This editorial article describes the effects of carbon monoxide poisoning on human beings and the mechanisms involving carbon monoxide saturation of haemoglobin that are responsible for it. The initial research done in the mid-1800s by Claude Bernard is presented. Methods of treatment for persons poisoned by carbon monoxide are discussed and the experiments made by J.B.S. Haldane on himself by breathing in carbon monoxide are described. Acclimatisation effects observed by Haldane and his co-workers and concerning persons occupationally exposed to carbon monoxide emissions are described.

  7. Simultaneous determination of dysprosium, holmium and erbium in high purity rare earth oxides by second order derivative spectrophotometry

    Anbu, M.; Prasada Rao, T.; Iyer, C. S. P.; Damodaran, A. D.

    1996-01-01

    High purity individual rare earth oxides are increasingly used as major components in lasers (Y 2 O 3 ), phosphors (YVO 3 , Eu 2 O 3 ), magnetic bubble memory films (Gd 2 O 3 ) and refractive-index lenses and fibre optics (La 2 O 3 ). The determination of individual lanthanides in high purity rare earth oxides is a more important and difficult task. This paper reports the utilization of higher order derivative spectrophotometry for the simultaneous determination of dysprosium, holmium and erbium in high purity rare earth oxides. The developed procedure is simple, reliable and allows the determination of 0.001 to 0.2% of dysprosium, holmium and erbium in several rare earth. (author). 9 refs, 2 figs, 2 tabs

  8. Holmium laser vs. conventional (cold knife) direct visual internal urethrotomy for short-segment bulbar urethral stricture: Outcome analysis.

    Jhanwar, Ankur; Kumar, Manoj; Sankhwar, Satya Narayan; Prakash, Gaurav

    2016-01-01

    Our goal was to analyze the outcome between holmium laser and cold knife direct visual internal urethrotomy (DVIU) for short-segment bulbar urethral stricture. We conducted a prospective study comprised of 112 male patients seen from June 2013 to December 2014. Inclusion criterion was short-segment bulbar urethral stricture (≤1.5cm). Exclusion criteria were prior intervention/urethroplasty, pan-anterior urethral strictures, posterior stenosis, urinary tract infection, and those who lost to followup. Patients were divided into two groups; Group A (n=58) included cold knife DVIU and group B (n=54) included holmium laser endourethrotomy patients. Patient followup included uroflowmetry at postoperative Day 3, as well as at three months and six months. Baseline demographics were comparable in both groups. A total of 107 patients met the inclusion criteria and five patients were excluded due to inadequate followup. Mean stricture length was 1.31 ± 0.252 cm (p=0.53) and 1.34 ± 0.251 cm in Groups A and B, respectively. Mean operating time in Group A was 16.3 ± 1.78 min and in Group B was 20.96 ± 2.23 min (p=0.0001). Five patients in Group A had bleeding after the procedure that was managed conservatively by applying perineal compression. Three patients in Group B had fluid extravasation postoperatively. Qmax (ml/s) was found to be statistically insignificant between the two groups at all followups. Both holmium laser and cold knife urethrotomy are safe and equally effective in treating short-segment bulbar urethral strictures in terms of outcome and complication rate. However, holmium laser requires more expertise and is a costly alternative.

  9. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  10. On the composition of nonstoichiometric europium monoxide

    Ignat'eva, N.I.

    1990-01-01

    Consideration is given to results of of investigation into chemical composition, homogeneity region, type of disordering of nonstoichiometric europium monoxide. Precision methods of X-ray diffraction, electron-microscopic, atomic-absorption chemical analysis were used. It is shown that lattice volume reduces with increase of oxygen content in the oxide. For monocrystal of EuO 1.01 composition a=5.146 A. All samples of europium monoxide are characterized by low conductivity. Conductivity value changes by two orders (from 10 -8 to 10 -6 Θ -1 ·cm -1 ) when passing from the sample of stoichiometric composition to maximally disordered one. The disordering is considered according to the type of charged cation vacancies, leading to occurrence of equivalent number of electron defects of positive holes. 4 refs.; 1 tab

  11. Sensorineural Hearing Loss following Carbon Monoxide Poisoning

    Joseph P. Pillion

    2012-01-01

    Full Text Available A case study is presented of a 17-year-old male who sustained an anoxic brain injury and sensorineural hearing loss secondary to carbon monoxide poisoning. Audiological data is presented showing a slightly asymmetrical hearing loss of sensorineural origin and mild-to-severe degree for both ears. Word recognition performance was fair to poor bilaterally for speech presented at normal conversational levels in quiet. Management considerations of the hearing loss are discussed.

  12. Carbon Monoxide Exposure in Youth Ice Hockey.

    Macnow, Theodore; Mannix, Rebekah; Meehan, William P

    2017-11-01

    To examine the effect of ice resurfacer type on carboxyhemoglobin levels in youth hockey players. We hypothesized that players in arenas with electric resurfacers would have normal, stable carboxyhemoglobin levels during games, whereas those in arenas with internal combustion engine (IC) resurfacers would have an increase in carboxyhemoglobin levels. Prospective cohort study. Enclosed ice arenas in the northeastern United States. Convenience sample of players aged 8 to 18 years old in 16 games at different arenas. Eight arenas (37 players) used an IC ice resurfacer and 8 arenas (36 players) an electric resurfacer. Carboxyhemoglobin levels (SpCO) were measured using a pulse CO-oximeter before and after the game. Arena air was tested for carbon monoxide (CO) using a metered gas detector. Players completed symptom questionnaires. The change in SpCO from pregame to postgame was compared between players at arenas with electric versus IC resurfacers. Carbon monoxide was present at 6 of 8 arenas using IC resurfacers, levels ranged from 4 to 42 parts per million. Carbon monoxide was not found at arenas with electric resurfacers. Players at arenas with IC resurfacers had higher median pregame SpCO levels compared with those at electric arenas (4.3% vs 1%, P carboxyhemoglobin during games and have elevated baseline carboxyhemoglobin levels compared with players at arenas with electric resurfacers. Electric resurfacers decrease the risk of CO exposure.

  13. The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode.

    Szewczyk, Mariusz; Jesionek-Kupnicka, Dorota; Lipiński, Marek Ireneusz; Lipinski, Piotr; Różański, Waldemar

    2014-01-01

    The aim of this study is to compare the changes in the incision line of prostatic adenoma using a monopolar cutting electrode and holmium laser, as well as the assessment of associated tissue mass and volume loss of benign prostatic hyperplasia (BPH). The material used in this study consisted of 74 preparations of prostatic adenoma obtained via open retropubic adenomectomy, with an average volume of 120.7 ml. The material obtained cut in vitro before fixation in formaldehyde. One lobe was cut using holmium laser, the other using a monopolar cutting electrode. After the incision was made, tissue mass and volume loss were evaluated. Thermocoagulation changes in the incision line were examinedunder light microscope. In the case of the holmium laser incision, the average tissue mass loss was 1.73 g, tissue volume loss 3.57 ml and the depth of thermocoagulation was 1.17 mm. When the monopolar cutting electrode was used average tissue mass loss was 0.807 g, tissue volume loss 2.48 ml and the depth of thermocoagulation was 0.19 mm. Where holmium laser was used, it was observed that the layer of tissue with thermocoagulation changes was deeper than in the case of the monopolar cutting electrode. Moreover, it was noticed that holmium laser caused bigger tissue mass and volume loss than the cutting electrode.

  14. Our first clinical experience with radiosynoviorthesis by means of (166)Ho-holmium-boro-macroaggregates.

    Kraft, Otakar; Kasparek, R; Ullmann, V; Melichar, F; Kropacek, M; Mirzajevov, M

    2005-01-01

    In this paper, we evaluate the therapeutic and adverse effects of the application of 166-holmium-boro-macroaggregates (HMBA) in radiosynovectomy (RSO) of the knees. We assessed the efficacy and safety of (166)Ho-HBMA in a prospective clinical trial in patients suffering from chronic synovitis. An effective component of radiopharmaceutical (166)Ho-boro-macroaggregates is radionuclide (166)Ho which has both beta-emission and gamma-emission. The physical half-life time of 166 Ho is 26.8 hours. After application of the radiopharmaceutical into a joint cavity, the effect of beta-emission causes radiation necrosis of pathologically changed (inflamed) synovial membrane. From 15th April 2005, we have started RSO of knees by means of new radiopharmaceutical (166)Ho-boro-macroaggregates in patients with gonarthrosis, rheumatoid arthritis, chronic synovitis, psoriatic arthritis, gout arthropathy. Seventeen intra-articular injections were performed in fifteen patients receiving a mean activity of 972 MBq (range: 904-1,057 MBq) (166)Ho-HMBA. The patients were hospitalized for three days. Side effects were evaluated during hospital stay and after 6-8 weeks. Static scintigraphy of knee joints and measurements of blood radioactivity were performed. Therapeutic effects were evaluated after 6-8 weeks. In 2 hours and 2 days after application, we proved, by means of knee and inguinal scintigraphy, only insignificant radiopharmaceutical leakage from the joint cavity to the inguinal lymph nodes in four patients. In treated patients, no serious adverse effects occurred. Nine patients were without complaints; 4 patients had slight knee exsudation and 2 patients had great exsudation. Therapeutic effects after 6-8 weeks were as follows: 2 patients were without pain, 9 with lower pain, 3 with the same pain and 1 patient with increased pain. Joint motion was improved in 7 patients, remained the same in 7 patients and was impaired in 1 patient. Analgesics consumption was lower in 5 patients

  15. Structure determination, electronic and optical properties of rubidium holmium polyphosphate RbHo(PO3)4

    Zhu, Jing; Chen, Hui; Wang, Yude; Guan, Hongtao; Xiao, Xuechun

    2012-12-01

    Structural, optical, and electronic properties of a new alkali metal-rare earth polyphosphate, RbHo(PO3)4, have been investigated by means of single-crystal X-ray diffraction, power X-ray diffraction, elemental analysis, and spectral measurement. RbHo(PO3)4 crystallizes in the monoclinic with space group P21/n and Z = 4. It is described as a three-dimensional (3D) architecture built up of PO4 double spiral chains and HoO8 polyhedra by corner-sharing. The 11-coordinated rubidium atoms are located in infinite tunnels. Additionally, in order to gain further insight into the relationship between property and structure of RbHo(PO3)4, theoretical calculation based on the density functional theory (DFT) was performed using the total-energy code CASTEP.

  16. Bone dissemination of prostate cancer after holmium laser enucleation of the prostate: a case report and a review of the literature.

    Koguchi, Dai; Nishi, Morihiro; Satoh, Takefumi; Shitara, Toshiya; Matsumoto, Kazumasa; Fujita, Tetsuo; Yoshida, Kazunari; Iwamura, Masatsugu

    2014-02-01

    We report a case of dissemination of prostate cancer after holmium laser enucleation of the prostate in an 80-year-old patient. The patient presented at hospital because of nocturia. Transrectal ultrasound-guided biopsy was carried out because of high serum prostate-specific antigen (3.55 ng/mL), but it showed no malignancies. Benign prostate hyperplasia was diagnosed, and he was started on an α1-blocker. Although the urinary symptom improved with silodosin, acute urinary retention occurred 3 years after therapy began. Holmium laser enucleation of the prostate for relief of bladder outlet obstruction enabled discharge of urine. Pathological examination of the resected tissue found adenocarcinoma with a high Gleason score, 4 + 5. Serum alkaline phosphatase increased rapidly after holmium laser enucleation, and bone scintigraphy confirmed multiple bone metastases. Prostate cancer, T1bN0M1b, was diagnosed. © 2013 The Japanese Urological Association.

  17. Transurethral lithotripsy with holmium-YAG laser of a large exogenous prostatic calculus.

    Hasegawa, Masanori; Ohara, Rei; Kanao, Kent; Nakajima, Yosuke

    2011-04-01

    Prostatic calculi are classified into two types, endogenous and exogenous calculi, based on their origin. Endogenous calculi are commonly observed in elderly men; however, exogenous prostatic calculi are extremely rare. We report here the case of a 51-year-old man who suffered incontinence and pollakiuria with a giant exogenous prostatic calculus almost completely replacing the prostatic tissue. X-rays and computed tomography demonstrated a large calculus of 65 × 58 mm in the small pelvic cavity. The patient underwent a transurethral lithotripsy with a holmium-YAG laser and a total of 85 g of disintegrated stones was retrieved and chemical stone analysis revealed the presence of magnesium ammonium phosphate. The incontinence improved and the voiding volume increased dramatically, and no stone recurrence in the prostatic fossa occurred at the 2 years follow-up. The etiology of this stone formation seemed to be based on some exogenous pathways combined with urinary stasis and chronic urinary infection due to compression fracture of the lumbar vertebra.

  18. Thermodynamic properties of the neutral and ionic components of the holmium trichloride vapor

    Kuznetsov, A.Yu.; Kudin, L.S.; Pogrebnoj, A.M.; Butman, M.F.; Burdukovskaya, G.G.

    1999-01-01

    The composition of saturated vapor above holmium trichloride in the temperature range of 887 - 1051 K is studied by the method of high-temperature mass spectrometry. Neutral components are presented by molecules of Ho n Cl 3n , n = 1 - 4 charged ones - by Cl - , HoCl 4 - , Ho 2 Cl 7 - ions. Sublimation enthalpies and formation enthalpies of gaseous molecules and ions (298 K): Δ s H Deg (HoCl 3 ) = 284 ±6, Δ s H Deg (Ho 2 Cl 6 ) = 352 ± 20; ΔH Deg (HoCl 3 ) = -722 ± 6; Δ f H Deg (Ho 2 Cl 6 ) = -1661 ± 20; Δ f H Deg (HoCl 4 - ) ≤ - 1191 ± 20, Δ f H Deg (Ho-2Cl 7 - ) ≤ -2127 ± 30 kJ/mol are determined. The value of electron affinity for HoCl 4 radical (A 0 ≥ 3.6 eV) is estimated [ru

  19. Laboratory investigation of the efficacy of holmium:YAG laser irradiation in removing intracanal debris

    Nuebler-Moritz, Michael; Gutknecht, Norbert; Sailer, Hermann F.; Hering, Peter; Prettl, Wilhelm

    1997-05-01

    Current endodontic therapy involves debridement and disinfection of the root canal by means of mechanical instrumentation and chemical irrigation. However, several studies have shown that these techniques fail to achieve complete cleansing. Recently, lasers have been suggested for use within root canals. This study was conducted to determine the efficacy of Holmium:YAG laser irradiation in removing intracanal debris and smear layer. Root canal surfaces of freshly-extracted human teeth were exposed to pulsed Ho:YAG laser radiation. Subsequently, laser induced structural changes were investigated using scanning electron microscopy. Temperature measurements during irradiation were performed by means of thermocouples. The result of this survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment survey give a preliminary indication of the ability of the Ho:YAG laser to improve current endodontic treatment modalities. However, limitations exist with regard to circumscribed and well-quantified irradiation of root canal surfaces, due to the lack of perpendicular delivery of the laser beam. Additional studies will be required to develop suitable optical transmission systems, in order to achieve complete cleansing and to avoid damage to the periradicular tissues, respectively.

  20. Microspheres of polyester loaded with Holmium-165: effect of gamma irradiation on the polymeric structure

    Azevedo, Mariangela de Burgos M. de; Pires, Geovanna; Lira, Rafael A. de; Geraldes, Adriana N.; Nascimento, Nanci; Melo, Vitor Hugo Soares de; Kodama, Yasko

    2011-01-01

    Biodegradable polymers containing radioactive isotopes have potential applications as delivery vehicles of beta radiation to the cancer tumors by brachytherapy. 166-Ho is an example of such radioisotope emitting high-energy beta particles, and also its gamma rays allow nuclear imaging in everywhere is applied. Among the biodegradable polymers, different types of poly(lactide) have been investigated in our laboratory, and poly(L-lactide) (PLLA) was used as substrate to prepare microparticles loaded with holmium acetylacetonate HoAcAc (PLLA-HoAcAc-MP). The aim of this study was to evaluate the stability of these microparticles to gamma radiation. The PLLA-HoAcAc-MP were irradiated in a nuclear reactor IEA-R1 at IPEN/CNEN-SP, and their stability studied out with gamma radiation of 25, 50 and 100 kGy doses. MP were characterized before and after irradiation by differential scanning calorimetry analysis (DSC), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), X-ray diffraction (XRD) and con focal laser scanning microscopy (CLSM). Preliminary results showed that gamma radiation did not damage morphologically the prepared PLLA-HoAcAc-MP in the dose range studied, and this procedure may be an important tool for knowing the stabilities of the polymers studied as MP for possible application in brachytherapy. (author)

  1. Development and evaluation of holmium doped phosphate glass microspheres for selective internal radiotherapy

    Barros Filho, Eraldo C.; Martinelli, Jose Roberto; Squair, Peterson L; Osso Junior, Joao A.; Sene, Frank Ferrer

    2013-01-01

    Selective Internal Radiotherapy is used to treat hepatocellular carcinoma. In this treatment 90 Y -doped aluminosilicate glass microspheres are introduced in the hepatic artery and they migrate to the liver near to the tumor where they are trapped in the arterioles. The radiation β- emitted by the decay of 90 Y annihilates the cancer cells. A macroaggregate of albumin containing technetium is previously used to monitor the lung shunt and to prevent the spreading of 90 Y during the treatment. In the present work, 165 Ho- doped phosphate glass microspheres were developed aiming that application. 165 Ho has high cross section for neutron capture (64 bars) and 166 Ho decays emitting β- radiation with appropriate energy for killing cancer cells, and gamma rays with low energy which can be used to obtain images of the microspheres location and to check possible occurrence of lung shunt. Holmium also is highly paramagnetic and can be used to obtain images whereby NMR. The glass matrix consists of (P 2 O 5 ) tetrahedrons and can be produced by a relatively lower melting temperature of chemical compounds. The 31 P decays by emitting β- radiation and contributes to the absorbed dose, helping to annihilate the cancer cells. The microspheres were produced by using two methods: the flame and the gravitation falling methods to obtain microspheres with appropriate properties. (author)

  2. Characteristics of exogenous carbon monoxide deliveries

    Hui-jun Hu

    2016-01-01

    Full Text Available Carbon monoxide (CO has long been considered an environmental pollutant and a poison. Exogenous exposure to amounts of CO beyond the physiologic level of the body can result in a protective or adaptive response. However, as a gasotransmitter, endogenous CO is important for multiple physiologic functions. To date, at least seven distinct methods of delivering CO have been utilized in animal and clinical studies. In this mini-review, we summarize the exogenous CO delivery methods and compare their advantages and disadvantages.

  3. Clinical effects of transcatheter hepatic arterial embolization with holmium-166 poly(l-lactic acid) microspheres in healthy pigs

    Vente, M.A.D.; Nijsen, J.F.W.; Wit, T.C. de; Schip, A.D. van het [University Medical Center Utrecht, Department of Nuclear Medicine, P.O. Box 85500, Utrecht (Netherlands); Seppenwoolde, J.H.; Seevinck, P.R. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Krijger, G.C. [Delft University of Technology, Department of Radiation, Radionuclides and Reactors, Faculty of Applied Sciences, Delft (Netherlands); Huisman, A. [University Medical Center Utrecht, Department of Clinical Chemistry and Haematology, Utrecht (Netherlands); Zonnenberg, B.A. [University Medical Center Utrecht, Department of Internal Medicine, Utrecht (Netherlands); Ingh, T.S.G.A.M. van den [TCCI Consultancy B.V., P.O. Box 85032, Utrecht (Netherlands)

    2008-07-15

    The aim of this study is to evaluate the toxicity of holmium-166 poly(l-lactic acid) microspheres administered into the hepatic artery in pigs. Healthy pigs (20-30 kg) were injected into the hepatic artery with holmium-165-loaded microspheres ({sup 165}HoMS; n = 5) or with holmium-166-loaded microspheres ({sup 166}HoMS; n = 13). The microspheres' biodistribution was assessed by single-photon emission computed tomography and/or MRI. The animals were monitored clinically, biochemically, and ({sup 166}HoMS group only) hematologically over a period of 1 month ({sup 165}HoMS group) or over 1 or 2 months ({sup 166}HoMS group). Finally, a pathological examination was undertaken. After microsphere administration, some animals exhibited a slightly diminished level of consciousness and a dip in appetite, both of which were transient. Four lethal adverse events occurred in the {sup 166}HoMS group due either to incorrect administration or comorbidity: inadvertent delivery of microspheres into the gastric wall (n = 2), preexisting gastric ulceration (n = 1), and endocarditis (n = 1). AST levels were transitorily elevated post-{sup 166}HoMS administration. In the other blood parameters, no abnormalities were observed. Nuclear scans were acquired from all animals from the {sup 166}HoMS group, and MRI scans were performed if available. In pigs from the {sup 166}HoMS group, atrophy of one or more liver lobes was frequently observed. The actual radioactivity distribution was assessed through ex vivo {sup 166m}Ho measurements. It can be concluded that the toxicity profile of HoMS is low. In pigs, hepatic arterial embolization with {sup 166}HoMS in amounts corresponding with liver-absorbed doses of over 100 Gy, if correctly administered, is not associated with clinically relevant side effects. This result offers a good perspective for upcoming patient trials. (orig.)

  4. [Carbon monoxide poisoning by a heating system].

    Dietz, Eric; Gehl, Axel; Friedrich, Peter; Kappus, Stefan; Petter, Franz; Maurer, Klaus; Püschel, Klaus

    2016-01-01

    A case of accidental carbon monoxide poisoning in several occupants of two neighboring residential buildings in Hamburg-Harburg (Germany) caused by a defective gas central heating system is described. Because of leaks in one of the residential buildings and the directly adjacent wall of the neighboring house, the gas could spread and accumulated in both residential buildings, which resulted in a highly dangerous situation. Exposure to the toxic gas caused mild to severe intoxication in 15 persons. Three victims died still at the site of the accident. Measures to protect the occupants were taken only with a great delay. As symptoms were unspecific, it was not realized that the various alarms given by persons involved in the accident were related to the same cause. In order to take appropriate measures in time it is indispensible to recognize, assess and check potential risks, which can be done by using carbon monoxide warning devices and performing immediate COHb measurements with special pulse oximeters on site. Moreover, the COHb content in the blood should be routinely determined in all patients admitted to an emergency department with unspecific symptoms.

  5. Cardiological aspects of carbon monoxide poisoning.

    Marchewka, Jakub; Gawlik, Iwona; Dębski, Grzegorz; Popiołek, Lech; Marchewka, Wojciech; Hydzik, Piotr

    2017-01-01

    The aim of this study was to assess cardiological manifestations of carbon monoxide (CO) poisoning. Background/introduction: Carbon monoxide intoxication is one of the most important toxicological causes of morbidity and mortality worldwide. Early clinical manifestation of CO poisoning is cardiotoxicity. We enrolled 75 patients (34 males and 41 females, mean age 37.6 ± 17.7 y/o) hospitalized due to CO poisoning. Laboratory tests including troponin I, blood pressure measurements, HR and electrocardiograms (ECG) were collected. Pach's scale scoring and grading system was used to establish severity of poisoning. Grade of poisoning is positively correlated with troponin I levels and systolic blood pressure. Moreover, troponin levels are significantly correlated with exposition time, lactates and are higher in tachycardiac, hypertensive and positive ECG subpopulations. COHb levels are indicative of exposure but do not correlate with grade of poisoning. The main cause of CO poisoning were bathroom heaters - 83%, only 11% of examined intoxicated population were equipped with CO detectors. Complex cardiological screening covering troponin levels, ECG, blood pressure and heart rate measurements as well as complete blood count with particular attention to platelet parameters should be performed in each case where CO intoxication is suspected. More emphasis on education on CO poisoning is needed.

  6. 40 CFR 86.1322-84 - Carbon monoxide analyzer calibration.

    2010-07-01

    ... be used. (2) Zero the carbon monoxide analyzer with either zero-grade air or zero-grade nitrogen. (3... columns is one form of corrective action which may be taken.) (b) Initial and periodic calibration. Prior... calibrated. (1) Adjust the analyzer to optimize performance. (2) Zero the carbon monoxide analyzer with...

  7. Hydrogen bonding of formamide, urea, urea monoxide and their thio

    Ab initio and DFT methods have been employed to study the hydrogen bonding ability of formamide, urea, urea monoxide, thioformamide, thiourea and thiourea monoxide with one water molecule and the homodimers of the selected molecules. The stabilization energies associated with themonohydrated adducts and ...

  8. Search of medical literature for indoor carbon monoxide exposure

    Brennan, T.; Ivanovich, M.

    1995-12-01

    This report documents a literature search on carbon monoxide. The search was limited to the medical and toxicological databases at the National Library of Medicine (MEDLARS). The databases searched were Medline, Toxline and TOXNET. Searches were performed using a variety of strategies. Combinations of the following keywords were used: carbon, monoxide, accidental, residential, occult, diagnosis, misdiagnosis, heating, furnace, and indoor. The literature was searched from 1966 to the present. Over 1000 references were identified and summarized using the following abbreviations: The major findings of the search are: (1) Acute and subacute carbon monoxide exposures result in a large number of symptoms affecting the brain, kidneys, respiratory system, retina, and motor functions. (2) Acute and subacute carbon monoxide (CO) poisonings have been misdiagnosed on many occasions. (3) Very few systematic investigations have been made into the frequency and consequences of carbon monoxide poisonings.

  9. Our first clinical experience with radiosynoviorthesis by means of 166Ho-holmium-boro-macroaggregates

    Kraft, O.; Ullmann, V.; Kasparek, R.; Melichar, F.; Kropacek, M.; Mirzajevova, M.

    2005-01-01

    In this paper, we evaluate the therapeutic and adverse effects of the application of 166- holmium-boro-macroaggregates (HMBA) in radiosynovectomy (RSO) of the knees. We assessed the efficacy and safety of 166H o-HBMA in a prospective clinical trial in patients suffering from chronic synovitis. An effective component of radiopharmaceutical 166H o-boro-macroaggregates is radionuclide 166H o which has both b-emission and g-emission. The physical half-life time of 166H o is 26.8 hours. After application of the radiopharmaceutical into a joint cavity, the effect of b-emission causes radiation necrosis of pathologically changed (inflamed) synovial membrane. From 15 april 2005, we have started RSO of knees by means of new radiopharmaceutical 166H o-boro-macroaggregates in patients with gonarthrosis, rheumatoid arthritis, chronic synovitis, psoriatic arthritis, gout arthropathy. Seventeen intra-articular injections were performed in fifteen patients receiving a mean activity of 972 MBq (range: 904.1057 MBq) 166H o-HMBA. The patients were hospitalized for three days. Side effects were evaluated during hospital stay and after 6.8 weeks. Static scintigraphy of knee joints and measurements of blood radioactivity were performed. Therapeutic effects were evaluated after 6.8 weeks. In 2 hours and 2 days after application, we proved, by means of knee and inguinal scintigraphy, only insignificant radiopharmaceutical leakage from the joint cavity to the inguinal lymph nodes in four patients. In treated patients, no serious adverse effects occurred. Nine patients were without complaints; 4 patients had slight knee exudation and 2 patients had great exudation. Therapeutic effects after 6.8 weeks were as follows: 2 patients were without pain, 9 with lower pain, 3 with the same pain and 1 patient with increased pain. Joint motion was improved in 7 patients, remained the same in 7 patients and was impaired in 1 patient. Analgesics consumption was lower in 5 patients, the same in 9

  10. Specific heat of holmium and YNi{sub 2}B{sub 2}C. Criticalbehaviour and superconducting properties; Spezifische Waerme von Holmium und YNi{sub 2}B{sub 2}C. Kritisches Verhalten und supraleitende Eigenschaften

    Bekkali, Abdelhakim

    2010-01-04

    Object of the thesis is the study of the specific heat of holmium and YNi{sub 2}B{sub 2}C in the temperature ranges from 50 to 200 KI respectively from 380 mK to 20 K in magnetic fields up to 9 T. In the present thesis the criticalbehaviour of YNi{sub 2}B{sub 2}C and properties of the superconducting state of tne non-magnetic rare-earth nickel borocarbide YNi{sub 2}B{sub 2}C are studied by means of a self-developed measurement apparatur of the specific heat using the quasi-adiabatic heating-pulse method as well as of holmium by means of the relaxation method. In this thesis reliable statements about the critical exponents on monocrystalline holmium could be made. The study on holmium proves that the critical behaviour of the specific heats cannot be described in the framework of the predictions of the chiral universality classes. By means of measurements of the specific heat in this thesis could be confirmed that YNi{sub 2}B{sub 2}C is a multiband superconductor. The positive curvature of the boundary line below T{sub c} in the phase diagram yields a first hint to the many-band character of YNI{sub 2}B{sub 2}C. In the zero-field the electronic specific heat in the superconducting state c{sub es}(T) can be not explained in the framework of the pure BCS theory. At low temperatures a residual contribution by normally conducting electrons could be detected, which hints to a not completely opened energy gap. A possible explanation would be that a band (or several bands) with low charge-carrier concentration not contribute to the superconductivity. This result agrees with de Haas-van Alphen measurements on isostructural superconducting LuNi{sub 2}B{sub 2}C monocrystals, which suggest the many-band character of the superconductivity as well as a vanishing energy gap in one band. The fluctuation behaviour of the specific heat of YNi{sub 2}B{sub 2}C in the neighbourhood of the superconducting-normally conducting transition agrees well with that of the 3D-XY model. [German

  11. Surface alloy formation by adsorption of holmium on Ag/Mo(112) bimetallic surfaces

    Kołaczkiewicz, Jan; Oleksy, Czesław

    2018-03-01

    Work function change measurements, low energy electron diffraction (LEED) and density functional theory (DFT) are used to determine the structures formed on Ag/Mo(112) bimetallic surfaces upon deposition of 0.5 monolayer (ML) of holmium. As the bimetallic surfaces, we have chosen the Mo(112) substrate covered with 1 or 2 ML of Ag. Such surfaces have the same symmetry as the Mo(112) face but different electronic properties. LEED experiment indicates that the c(2 × 2) structure is formed on (1 ML Ag)/Mo(112) bimetallic surface upon deposition of 0.5 ML of Ho. DFT calculations show that a type of Ag-Ho surface alloy is formed, with Ho atoms 0.6 Å below the distorted layer of Ag. This is neither a substitutional nor a subsurface alloy. It is found that the adsorption structure formed on the (2 ML Ag)/Mo(112) bimetallic surface depends on the annealing temperature. After deposition of 0.5 ML of Ho at 300 K, the LEED pattern of p(2 × 2) symmetry is observed. Annealing of the overlayer at 640 K irreversibly changes the p(2 × 2) pattern into a pattern of c(2 × 2) type. The results of DFT computations show that the c(2 × 2) structure of the Ag-Ho surface alloy is energetically most favorable. In this structure, 0.5 ML of Ho is between the two monolayers of Ag, and the symmetry of the topmost layer is changed. The work function change calculated for the c(2 × 2) structure is in a good agreement with the measured value (0.22 eV). The results show that adsorption of Ho on the Ag/Mo(112) bimetallic surfaces is substantially different than on the clean Mo(112).

  12. Studies on therapeutic method of liver cancer(hapatocellular carcinome)by Holmium-166 radionuclide

    Lee, Jong Tae; Yoo, H. S.; Kim, M. J.; Han, K. H.; Park, C. I. [Yonsei University Medical College, Seoul (Korea, Republic of)

    1997-07-01

    As the study of radioactive nuclide, Holmium-166 in the treatment of liver cancer(hepatocellular carcinoma), this study was performed under the base of animal experimental. Using dog liver, percutaneous injection of Ho-166 MAA or chitosan with premade dose was done under the ultrasound guidance. Continuously the same procedure as previous one was performed in the skin hapatoma, which was developed by the injection of hepatocellular carcinoma cell in the nude mouse, In case of injected normal liver of dog, imaging study including ultrasound, CT and MRI was done in order to evaluate effect of Ho-166 and pathologic reaction. The result showed well defined nectosis of normal liver as well as skin hepatoma. The area of nectosis is dependent on the dose of injected Ho-166. Generally, pathologic reaction is tissue coagulation nectosis, Ho-166 particles, fibrosis and hemorrhage. In the clinical study, 50 patients with hapatoma was selected for this study under the agreement of patient. Under ultrasound guidance percutaneous injection of Ho-166 Maa or chitosan to tumor was performed and follow-up study was extended from 6 to 12 month. The result showed that 64% of patient were completely treated. Overall, the effect of treatment could be obtained in 41 patient (82%) among 50 hepatoma patient. Conclusively Ho-166 is thought to be a compromising agent in the treatment of hepatocellular carcinoma and one of therapeutic modality, if it is established internally and world-wide. In the future, the popular percutaneous ethanol injection method will be replaced to this method. 19 refs., 1 tabs., 14 figs. (author)

  13. Factors affecting de novo urinary retention after Holmium laser enucleation of the prostate.

    Sung Han Kim

    Full Text Available OBJECTIVE: Patients can experience urinary retention (UR after Holmium laser enucleation of the prostate (HoLEP that requires bladder distension during the procedure. The aim of this retrospective study is to identify factors affecting the UR after HoLEP. MATERIALS AND METHODS: 336 patients, which underwent HoLEP for a symptomatic benign prostatic hyperplasia between July 2008 and March 2012, were included in this study. Urethral catheters were routinely removed one or two days after surgery. UR was defined as the need for an indwelling catheter placement following a failure to void after catheter removal. Demographic and clinical parameters were compared between the UR (n = 37 and the non-urinary retention (non-UR; n = 299 groups. RESULTS: The mean age of patients was 68.3 (±6.5 years and the mean operative time was 75.3 (±37.4 min. Thirty seven patients (11.0% experienced a postoperative UR. UR patients voided catheter free an average of 1.9 (±1.7 days after UR. With regard to the causes of UR, 24 (7.1% and 13 (3.9% patients experienced a blood clot-related UR and a non-clot related UR respectively. Using multivariate analysis (p0.05. CONCLUSIONS: De novo UR after HoLEP was found to be self-limited and it was not related to learning curve, patient age, diabetes, or operative time. Efficient morcellation and careful control of bleeding, which reduces clot formation, decrease the risk of UR after HoLEP.

  14. Holmium laser urethrotomy for treatment of traumatic stricture urethra: a review of 78 patients.

    Hussain, Manzoor; Lal, Murli; Askari, Syed Hasan; Hashmi, Altaf; Rizvi, Syed Adibul Hasan

    2010-10-01

    To evaluate the efficacy and long-term results of laser urethrotomy as minimally invasive treatment for traumatic stricture urethra. Between January 2006 and June 2008, 78 male patients were treated with Holmium Laser urethrotomy. 16 Fr urethroscope was used through which 600um laser fiber was introduced through side channel. Stricture was visualized and incised at 12 o'clock position with energy set at 1500-2000 MJ at pulse rate of 10-12. Two other incisions were given at 2 and 10 o'clock positions. Further ablation was done till 16Fr Foley's catheter was passed. Patients were followed in a stricture clinic. Patients age ranged from 15-73 years. All strictures were due to trauma, Road traffic accident in 40 (52%) post catheter trauma 4 (5%), fall as ride 27 (35%) and failed urethroplasty 7 (8%). Site of stricture was bulbar 57 (73%), bulbomembranous 16 (20%) and membranoprostatic 5 (2.5%). Length of stricture ranged from 0.8-2.5 cms. At 3 months follow-up, 60 (77%) patients remained catheter and symptoms free while 18 (23%) developed recurrence of stricture but at the end of 36 months follow-up success rate decreased to 47 (60%). Among those who developed re-strictures, 6 ( 7.6%) had 2nd sitting laser while 4 (5.1%) had urethroplasty, and others were on intermittent dilatation. Immediate complications were sepsis 10 (13%), extravasation 2 (4%), failed urethrotomy 2 (4%) and mild haematuria 3 (5.8%). Hospital stay ranged from day care to 3 days. Laser urethrotomy is minimally invasive and an effective treatment for short strictures in bulbarurethra. The recurrence rate is 40% in the long-term follow-up and is more commonly seen in completely obliterated strictures.

  15. Holmium laser enucleation of the prostate and retropubic prostatic adenomectomy: morbidity analysis and anesthesia considerations.

    Soto-Mesa, D; Amorín-Díaz, M; Pérez-Arviza, L; Fernández-Pello Montes, S; Martín-Huéscar, A

    2015-11-01

    Holmium laser enucleation of the prostate (HoLEP) is an alternative to prostatic adenomectomy for the surgical treatment of benign prostatic hypertrophy. We analyzed our learning curve for this technique, and we compared it in a secondary manner with prostatic adenomectomy. A retrospective comparative study was conducted that included the first 100 cases of HoLEP performed in our center and the latest 50 cases of retropubic adenomectomy. We collected data on the patients, the surgery, the anesthesia, the perioperative variables, the anesthesia complications and the postoperative variables, with a 6-month follow-up. We analyzed the learning curve without mentors for HoLEP and compared the characteristics of HoLEP in 2 separate phases (learning and stabilization phases) with the latest retropubic prostatic adenomectomies performed. Intradural anesthesia was the most common technique. The transfusion needs, length of stay (P<.01) and postoperative morbidity were lower for HoLEP than for adenomectomy. However, the retropubic adenomectomy group had larger initial prostate volumes (P<.001) and shorter surgical times (P<.001). Better surgical performance (P<.001) and a lower incidence of complications were observed in the HoLEP-B group (once the learning curve had been overcome) compared with the HoLEP-A group. In our center, HoLEP was introduced as a valid alternative to open retropubic adenomectomy, with excellent results in terms of morbidity and reduced hospital stay. In terms of the learning curve, we consider that approximately 50 patients (without mentor) is an appropriate cutoff. Local anesthesia is a good choice for the anesthesia technique. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Holmium laser urethrotomy for treatment of traumatic stricture urethra: A review of 78 patients

    Hussain, M.; Lal, M.; Askari, S.H.; Hashmi, A.; Rizvi, S.A.H.

    2010-01-01

    To evaluate the efficacy and long-term results of laser urethrotomy as minimally invasive treatment for traumatic stricture urethra. Methods: Between January 2006 and June 2008, 78 male patients were treated with Holmium Laser urethrotomy. 16 Fr urethroscope was used through which 600um laser fiber was introduced through side channel. Stricture was visualized and incised at 12 o'clock position with energy set at 1500-2000 MJ at pulse rate of 10-12. Two other incisions were given at 2 and 10 o'clock positions. Further ablation was done till 16 Fr Foley's catheter was passed. Patients were followed in a stricture clinic. Results: Patients age ranged from 15-73 years. All strictures were due to trauma, Road traffic accident in 40(52%) post catheter trauma 4(5%), fall as ride 27(35%) and failed urethroplasty 7(8%). Site of stricture was bulbar 57(73%), bulbomembranous 16(20%) and membranoprostatic 5(2.5%). Length of stricture ranged from 0.8-2.5 cms. At 3 months follow-up, 60(77%) patients remained catheter and symptoms free while 18(23%) developed recurrence of stricture but at the end of 36 months follow-up success rate decreased to 47 (60%). Among those who developed re-strictures, 6(7.6%) had second sitting laser while 4(5.1%) had urethroplasty, and others were on intermittent dilatation. Immediate complications were sepsis 10(13%), extravasation 2(4%), failed urethrotomy 2(4%) and mild haematuria 3(5.8%). Hospital stay ranged from day care to 3 days. Conclusion: Laser urethrotomy is minimally invasive and an effective treatment for short strictures in bulbar urethra. The recurrence rate is 40% in the long-term follow-up and is more commonly seen in completely obliterated strictures. (author)

  17. Effects of Intraluminal Irradiation with Holmium-166 for TIPS Stenosis: Experimental Study in a Swine Model

    Park, Ji Seon; Oh, Joo Hyeong; Kim, Deog Yoon; Park, Yong Koo; Kim, Soo Joong [Kyung Hee University Medical Center, Seoul (Korea, Republic of); Park, Sang Joon [Kang Dong Sacred Heart Hospital, Hallym University, Seoul (Korea, Republic of)

    2007-04-15

    We wanted to evaluate the effectiveness of intraluminal irradiation with Holmium-166 ({sup 166}Ho) for reducing the pseudointimal hyperplasia (PIH) in the transjugular intrahepatic portosystemic shunt (TIPS) tract in a swine model. TIPS was performed in 12 domestic pigs, after the creation of portal hypertension by intraportal injection of a mixture of N-butyl-2- cyanoacrylate (NBCA) and lipiodol. Five pigs first underwent intraluminal irradiation (30 Gy) in the parenchymal tract with using a {sup 166}Ho solution-filled balloon catheter, and this was followed by the placement of a nitinol stent in the TIPS tract. For the seven control pigs, the balloon was filled with saline and contrast media mixture. Two weeks later, follow-up portography and histological analysis were performed. TIPS was successfully performed in all twelve pigs with achieving artificially induced portal hypertension. Portography performed two weeks after TIPS showed the patent tracts in the TIPS tracts that were irradiated with {sup 166}Ho (5/5, 100%), whereas either completely (5/6, 83.3%) or partially (1/6, 16.7%) occluded TIPS were seen in the seven pigs of the nonirradiated control group, except in one pig that experienced periprocedural death due to bleeding. Histological analysis showed a statistically significant difference for the maximal PIH (irradiated: 32.8%, nonirradiated: 76.0%, p < 0.001) between the two groups. Intraluminal irradiation with 30 Gy of {sup 166}Ho for TIPS significantly improved the TIPS patency in a swine model of portal hypertension during a 2- week period of follow-up.

  18. Gamma spectrometry and chemical characterization of bioactive glass seeds with Holmium-166 for oncological implants

    Valente, Eduardo S.

    2009-01-01

    Bioactive glass seeds synthesized by the sol-gel technique with Si:Ho:Ca composition with natural holmium incorporated were irradiated in the TRIGA type nuclear reactor IPR-R1 at 100kW, in the central thimble where the thermal neutron flux is 2.8x10 12 n/cm 2 .s and the epithermal neutron flux is 2.6 X 10 11 n/cm 2 .s . After an 8 hour irradiation time, with an induced activity close to 110MBq/seed, a set of seeds was submitted to Gamma Spectrometry Analysis in a counting system with an HPGe detector, ORTEC electronic instrumentation and a Camberra Multichannel Analyser, to determine all radionuclides present on the sample as well as its individual activities. Special attention was paid on the discrimination of Si, 40 Ca, 44 Ca, C and Ho as the other expected elements like 48 Ca, 2 H and 18 O were present in traces or have very short half-lives. The second sample was submitted to Plasma spectrometry to determine the 166 Ho concentration in weight. The third sample was submitted to an X-ray spectrometry in a JEOL-JXA-8900RL equipment to determine its qualitative chemical composition, in order to evaluate impurities and nominal composition. It was determined that most of the activity, after decaying of short half-life elements, was due to 166 Ho present on the sample, with a well characterized β and gamma spectra. The homogeneity of the seeds was tested on the X-ray spectrometry, and verified that there is no discrepancy in composition from distinct seeds or in a same seed. The results are relevant on the investigation of the viability of producing 166 Ho radioactive seeds for oncological implants. (author)

  19. Thermal Reactions in Mixtures of Micron-sized Silicon Monoxide and Titanium Monoxide - Redox Paths Overcoming Passivation Shells.

    Jandová, Věra; Pokorná, Dana; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, Petra; Pola, Josef

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 R&D Projects: GA TA ČR TA04010169 Institutional support: RVO:67985858 Keywords : silicon monoxide * titanium monoxide * hifh-temperature Subject RIV: CF - Physical ; Theoretical Chemistry OBOR OECD: Physical chemistry Impact factor: 1.369, year: 2016

  20. Thermal reactions in mixtures of micron-sized silicon monoxide and titanium monoxide: redox paths overcoming passivation shells

    Jandová, V.; Pokorná, D.; Kupčík, Jaroslav; Bezdička, Petr; Křenek, T.; Netrvalová, M.; Cuřínová, P.; Pola, J.

    2018-01-01

    Roč. 44, č. 1 (2018), s. 503-516 ISSN 0922-6168 Institutional support: RVO:61388980 Keywords : Silicon monoxide * Titanium monoxide * High-temperature * Oxygen-transfer reactions * Titanium suboxides * Titanium silicide * Methylene blue depletion Subject RIV: CA - Inorganic Chemistry OBOR OECD: Inorganic and nuclear chemistry Impact factor: 1.369, year: 2016

  1. Wideband thulium–holmium-doped fiber source with combined forward and backward amplified spontaneous emission at 1600–2300 nm spectral band

    Honzátko, Pavel; Baravets, Yauhen; Kašík, Ivan; Podrazký, Ondřej

    2014-01-01

    Roč. 39, č. 12 (2014), s. 3650-3653 ISSN 0146-9592 R&D Projects: GA ČR(CZ) GAP205/11/1840 Institutional support: RVO:67985882 Keywords : Bandwidth * Spontaneous emission * Holmium Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.292, year: 2014

  2. 2.05 µm holmium-doped all-fiber laser diode-pumped at 1.125 µm

    Kir'yanov, A. V.; Barmenkov, Y. O.; Villegas Garcia, I.

    2017-08-01

    We report a holmium-doped all-fiber laser oscillating at ~2.05 µm in continuous wave at direct in-core pumping by a 1.125 µm laser diode. Two types of home-made holmium-doped alumino-germano-silicate fiber (HDF), differentiated in the Ho3+ doping level, were fabricated to implement the laser, for revealing the effect of Ho3+ concentration upon the laser output. Firstly, the fibers were characterized thoroughly from the material and optical viewpoints. Then, laser action with both HDFs was assessed using the simplest Fabry-Perot cavity, assembled by a couple of spectrally adjusted fiber Bragg gratings, also made-in-house. In the best case, when using the lower-doped HDF of proper length (1.4 m), low threshold (~370 mW) and moderate slope efficiency (~13%) of ~2.05 µm lasing were obtained at 1.125 µm diode pumping. Long-term stability, high brightness, low noise, and purely CW operation are shown to be the laser’s attractive features. Yet, when utilizing the heavier-doped HDF, laser output is revealed to be overall worse, with a possible reason being the deteriorating Ho3+ concentration-related effects.

  3. Safety analysis of holmium-166 microsphere scout dose imaging during radioembolisation work-up. A cohort study

    Braat, Arthur J.A.T.; Prince, Jip F.; Rooij, Rob van; Bruijnen, Rutger C.G.; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands)

    2018-03-15

    Radioembolisation is generally preceded by a scout dose of technetium-99m-macroaggregated albumin to estimate extrahepatic shunting of activity. Holmium-166 microspheres can be used as a scout dose (±250 MBq) and as a therapeutic dose. The general toxicity of a holmium-166 scout dose ({sup 166}Ho-SD) and safety concerns of an accidental extrahepatic deposition of {sup 166}Ho-SD were investigated. All patients who received a {sup 166}Ho-SD in our institute were reviewed for general toxicity and extrahepatic depositions. The absorbed dose in extrahepatic tissue was calculated on SPECT/CT and correlated to clinical toxicities. In total, 82 patients were included. No relevant clinical toxicity occurred. Six patients had an extrahepatic deposition of {sup 166}Ho-SD (median administered activity 270 MBq). The extrahepatic depositions (median activity 3.7 MBq) were located in the duodenum (3x), gastric fundus, falciform ligament and the lesser curvature of the stomach, and were deposited in a median volume of 15.3 ml, which resulted in an estimated median absorbed dose of 3.6 Gy (range 0.3-13.8 Gy). No adverse events related to the extrahepatic deposition of the {sup 166}Ho-SD occurred after a median follow-up of 4 months (range 1-12 months). These results support the safety of 250 MBq {sup 166}Ho-SD in a clinical setting. (orig.)

  4. The application of x-ray spectrometry to isotopic-source activation analysis of dysprosium and holmium

    Pillay, A.E.; Mboweni, R.C.M.

    1990-01-01

    A novel aspect of activation analysis is described for the determination of dysprosium and holmium at low concentrations. The method involves the measurement of K x-rays from radionuclides produced by thermal neutron activation using a 1 mg 252 Cf source. The basis for elemental selection depends largely on the demand for analysis and on the existence of favourable nuclear properties for the production of a practicable x-ray yield. A full appraisal of the analytical potential of the method is presented with particular emphasis on its application to geological matrices. The sensitivity was optimised by employing a detector that was particularly effective at photon energies below 150 keV. Analytical conditions are demonstrated for the elements of interest over a wide range of concentrations in small powdered samples. The investigation formed the basis of a feasibility study to establish if the application could be developed for the routine off-line determination of dysprosium and holmium using an isotopic-neutron source. (author)

  5. Residential indoor air quality guideline : carbon monoxide

    2010-01-01

    Carbon monoxide (CO) is a tasteless, odourless, and colourless gas that can be produced by both natural and anthropogenic processes, but is most often formed during the incomplete combustion of organic materials. In the indoor environment, CO occurs directly as a result of emissions from indoor sources or as a result of infiltration from outdoor air containing CO. Studies have shown that the use of specific sources can lead to increased concentrations of CO indoors. This residential indoor air quality guideline examined the factors influencing the introduction, dispersion and removal of CO indoors. The health effects of exposure to low and higher concentrations of CO were discussed. Residential maximum exposure limits for CO were presented. Sources and concentrations in indoor environments were also examined. 17 refs., 2 tabs.

  6. Recent changes in atmospheric carbon monoxide

    Novelli, P.C.; Masarie, K.A. (Univ. of Colorado, Boulder, CO (United States)); Tans, P.P.; Lang, P.M. (National Oceanic and Atmospheric Administration, Boulder, CO (United States))

    1994-03-18

    Measurements of carbon monoxide (CO) in air samples collected from 27 locations between 71[degrees]N and 41[degrees]S show that atmospheric levels of this gas have decreased worldwide over the past 2 to 5 years. During this period, CO decreased at nearly a constant rate in the high northern latitudes. In contrast, in the tropics an abrupt decrease occurred beginning at the end of 1991. In the Northern Hemisphere, CO decreased at a spatially and temporally averaged rate of 7.3 ([+-]0.9) parts per billion per year (6.1 percent per year) from June 1990 to June 1993, whereas in the Southern Hemisphere, CO decreased 4.2 ([+-]0.5) parts per billion per year (7.0 percent per year). This recent change is opposite a long-term trend of a 1 to 2 percent per year increase inferred from measurements made in the Northern Hemisphere during the past 30 years.

  7. Carbon monoxide budget in the northern hemisphere

    Bakwin, P.S.; Tans, P.P. (Climate Monitoring and Diagnostics Lab., Boulder, CO (United States)); Novelli, P.C. (Univ. of Colorado, Boulder, CO (United States))

    1994-03-15

    To improve urban air quality the major industrialized nations of the West took steps during the 1970s and 1980s to reduce carbon monoxide (CO) emissions from automobiles and other industrial sources. Overall, CO/CO[sub 2] emission ratios from the mix of fossil fuel combustion sources have been reduced by about half during 1976-1990. Also, the tropospheric abundance of hydroxyl radical (OH), which is the main sink for CO, is proposed to have increased globally by about 1.0 [+-] 0.8% yr[sup [minus]1]. The authors use a simple two-box model to examine the impact of shrinking emissions and increasing OH on the global abundance of CO. They find that these factors contribute about equally in reducing CO levels in the Northern Hemisphere troposphere by about 1.8 [+-] 0.8 ppb yr[sup [minus]1] on average. 19 refs., 1 fig.

  8. Health effects of carbon monoxide environmental pollution

    1974-01-01

    Carbon monoxide's (CO) chronic effects on man, its sources, and measuring methods are reviewed, and guidelines to determine health criteria are considered. The European data exchange included CO measuring methods in air and blood and their use in survey and experimental work, atmospheric CO pollution and sampling methods in urban thoroughfares and road tunnels in the European countries, a population survey of carboxyhemoglobin levels from cigarette smoking and atmospheric exposure, and physiological kinetics (uptake, distribution, and elimination) of CO inhalation. Additional topics are CO and the central nervous system, effects of moderate CO exposure on the cardiovascular system and on fetal development, and the current views on existing air quality criteria for CO.

  9. Therapeutic application of new holmium-166 chitosan complex in malignant and benign diseases

    Park, K.B.; Kim, Y.M.; Shin, B.C.; Kim, J.R.; Ryu, J.M.; Lim, S.M.

    1998-01-01

    The new holmium-166 chitosan complex ( 166 Ho-CHICO, DW- 166 HC) was prepared by reacting the aqueous acidic solution of chitosan with 166 Ho(NO 3 ) 3 at room temperature with quantitative labelling yield. The progress of the reaction and labelling yield were determined by instant this layer chromatography using silicic acid impregnated glass fiber (ITLC-SA) and developing solvent of MeOH:H 2 O:HAC (49:49:2). The high labelling yield of more than 99% was obtained by reacting chitosan solution (35 mg/4 ml) with 166 Ho(NO 3 ) 3 in which 7 mg of 165 Ho+ 166 Ho were contained as a maximum content. The labelling yield was highly dependent on the pH of the chitosan solution. The optimal labelling could be obtained at pH 2.5∼3.5 The characteristics of 166 Ho-CHICO were similar to those of chitosan, which is biocompatible, biodegradable, non-toxic, soluble and viscous in acidic condition but geltatinuous at pH 6.0 and precipitating in alkaline conditions. 166 Ho-CHICO can be easily prepared by reconstituting freeze-dried chitosan (kit A) with 166 Ho(NO 3 ) 3 solution (kit B) just prior to use. After intrahepatic administration of 166 Ho-CHICO to male rats, the radioactivity concentrations in blood were low and the cumulative urinary and fecal excretion over a period of 0 to 72 hours were 0.53% and 0.54%, respectively. the radioactivity concentration in tissues and the whole-body autoradiography images showed that most of the administered radioactivity was localized at the administered site, and only slight radioactivity was detected from the liver, spleen, lungs, and bones. An autoradiograph after intratumoral administration of 166 Ho-CHICO showed that radioactivity was localized at the administered site of the lesion without distribution to other organs and tissues. A biodistribution study in normal rabbits with 166 Ho-CHICO showed that most of the radioactivities were retained in the knee joint with negligible extra leakage at 72 hours after intra

  10. Determinants of holmium:yttrium-aluminum-garnet laser time and energy during ureteroscopic laser lithotripsy.

    Molina, Wilson R; Marchini, Giovanni S; Pompeo, Alexandre; Sehrt, David; Kim, Fernando J; Monga, Manoj

    2014-04-01

    To evaluate the association of preoperative noncontrast computed tomography stone characteristics, laser settings, and stone composition with cumulative holmium:yttrium-aluminum-garnet (Ho:YAG) laser time/energy. We retrospectively reviewed patients who underwent semirigid/flexible ureteroscopy and Ho:YAG laser lithotripsy (200 or 365 μm laser fiber; 0.8-1.0 J energy; and 8-10 Hz rate) at 2 tertiary care centers (April 2010-May 2012). Studied parameters were as follows: patient's characteristics; stone characteristics (location, burden, hardness, and composition); total laser time and energy; and surgical outcomes. One hundred patients met our inclusion criteria. Mean stone size was 1.01 ± 0.42 cm and volume 0.33 ± 0.04 cm(3). Mean stone radiodensity was 990 ± 296 HU, and Hounsfield units density 13.8 ± 6.0 HU/mm. All patients were considered stone free. Stone size and volume had a significant positive correlation with laser energy (R = 0.516, P R = 0.621, P R = 0.477, P R = 0.567, P stone size, only the correlation between HU and laser time was significant (R = 0.262, P = .011). In the multivariate analysis, with exception of stone composition (P = .103), all parameters significantly increased laser energy (R(2) = 0.524). Multivariate analysis revealed a positive significant association of laser time with stone volume (P R(2) = 0.512). In multivariate analysis for laser energy, only calcium phosphate stones required less energy to fragment compared with uric acid stones. No significant differences were found in the multivariate laser time model. Ho:YAG laser cumulative energy and total time are significantly affected by stone dimensions, hardness location, fiber size, and power. Kidney location, laser fiber size, and laser power have more influence on the final laser energy than on the total laser time. Calcium phosphate stones require less laser energy to fragment. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Radiosynoviorthesis of knees by means of 166Ho-holmium-boro-macroaggregates.

    Kraft, Otakar; Kaspárek, Richard; Ullmann, Vojtech; Melichar, Frantisek; Kropácek, Martin; Mirzajevova, Marcela

    2007-04-01

    The aim of this study was to evaluate adverse and therapeutic effects of applicated holmium-boro-macroaggregates (HBMAs) in the radiosynoviorthesis (RSO) of knees in patients suffering from chronic synovitis. We started RSO of the knees by means of a new radiopharmaceutical (RF) HBMA in patients with gonarthrosis, rheumatoid arthritis, chronic synovitis, psoriatic arthritis, and gout arthropathy. Seventeen (17) intra-articular injections were performed in 15 patients who were receiving a mean activity of 972 MBq (range, 904-1057) of 166Ho-HBMA. Patient inclusion to the study followed a series of inclusion and exclusion criterions. The patients were hospitalized for 3 days. Side-effects were evaluated during their hospital stay and again after 6-8 weeks. Static scintigraphy of knee joints and measurements of blood radioactivity were performed. Therapeutic effects were evaluated after 6-8 weeks and at 6 months. In 2 hours and 2 days following the application, we proved, by means of knee and inguinal scintigraphy, only insignificant radiopharmaceutical leakage from the joint cavity to the inguinal lymph nodes in 4 patients. In the treated patients, no serious adverse effects occurred. Nine (9) patients were without complaints, 4 patients had slight knee exudation, and 2 patients had great exudation. Therapeutic effects were as follows: 2 patients were without pain, 9 were with lower pain, 3 were with the same pain, and 1 patient was with increased pain. Joint motion was improved in 7 patients, remained the same in 7 patients, and was impaired in 1 patient. Analgesics consumption was lower in 5 patients, the same in 9 patients, and greater in 1 patient. Knee exudation was absent in 2 patients, lower in 4 patients, the same in 6 patients, and greater in 3 patients. In 3 patients it was necessary to do surgical RSO. This RF can extend the range of clinically used radiopharmaceuticals for RSO and to supplement space between 90Y with high energy and 186Re with 169Er with

  12. CT and clinical patterns in suicidal carbon monoxide

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-01-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications. (orig.) [de

  13. Atmospheric analyzer, carbon monoxide monitor and toluene diisocyanate monitor

    Shannon, A. V.

    1977-01-01

    The purpose of the atmospheric analyzer and the carbon monoxide and toluene diisocyanate monitors is to analyze the atmospheric volatiles and to monitor carbon monoxide and toluene diisocyanate levels in the cabin atmosphere of Skylab. The carbon monoxide monitor was used on Skylab 2, 3, and 4 to detect any carbon monoxide levels above 25 ppm. Air samples were taken once each week. The toluene diisocyanate monitor was used only on Skylab 2. The loss of a micrometeoroid shield following the launch of Skylab 1 resulted in overheating of the interior walls of the Orbital Workshop. A potential hazard existed from outgassing of an isocyanate derivative resulting from heat-decomposition of the rigid polyurethane wall insulation. The toluene diisocyanate monitor was used to detect any polymer decomposition. The atmospheric analyzer was used on Skylab 4 because of a suspected leak in the Skylab cabin. An air sample was taken at the beginning, middle, and the end of the mission.

  14. Hydrogenation of carbon monoxide over supported palladium catalysts

    Fujimoto, K.; Hashimoto, H.; Kunugi, T.

    1978-03-01

    An alumina-supported 2% palladium catalyst had higher activity for carbon monoxide hydrogenation than a silica-supported 2% palladium catalyst, at 250/sup 0/-400/sup 0/C and 1 atm. The addition of lanthanum oxide or thorium oxide, but not of potassium oxide, to the silica-supported catalyst increased the conversion at 350/sup 0/C from 1.1% to 81.0% with a selectivity of 56.1% for methane, 1.4% for C/sub 2/ compounds, 0.1% for C/sub 3/ compounds, and 42.5% for carbon dioxide. Temperature-programed desorption of carbon monoxide in a hydrogen stream showed that of two desorption peaks observed for carbon monoxide, the one at higher temperature corresponded to the carbon monoxide species which hydrogenates to methane and that the area of this peak increased with increasing thorium content of the catalyst. Graphs, tables, and 12 references.

  15. Carbon Monoxide Hazards from Small Gasoline Powered Engines

    ... DHHS (NIOSH) Publication No. 96-118 (1996) Describes health effects and current standards and guidelines relating to carbon monoxide, as well as recommendations for workers, employers, and manufacturers regarding small gasoline powered engine ...

  16. An interesting cause of pulmonary emboli: Acute carbon monoxide poisoning

    Sevinc, A.; Savli, H.; Atmaca, H. [Gaziantep University, Gaziantep (Turkey). School of Medicine

    2005-07-01

    Carbon monoxide poisoning, a public health problem of considerable significance, is a relatively frequent event today, resulting in thousands of hospitalizations annually. A 70-year-old lady was seen in the emergency department with a provisional diagnosis of carbon monoxide poisoning. The previous night, she slept in a tightly closed room heated with coal ember. She was found unconscious in the morning with poor ventilation. She had a rare presentation of popliteal vein thrombosis, pulmonary emboli, and possible tissue necrosis with carbon monoxide poisoning. Oxygen treatment with low-molecular-weight heparin (nadroparine) and warfarin therapy resulted in an improvement in both popliteal and pulmonary circulations. In conclusion, the presence of pulmonary emboli should be sought in patients with carbon monoxide poisoning.

  17. CT and clinical patterns in suicidal carbon monoxide

    Grobovschek, M.; Geretsegger, C.; Weinberger, R.; Fartacek, R.

    1988-12-01

    Cranial CT is important to exclude the presence of a mass in the cavum cranii in case of an unclear suicide attempt, particularly a traumatic mass. It can be helpful also in cases of carbon monoxide intoxications.

  18. In vitro study of morphological and chemical modification threshold of bovine dental enamel irradiated by the holmium laser

    Eduardo, Patricia Lerro de Paula

    2001-01-01

    The aim of this study is to investigate the Ho:YLF laser effects on the dental enamel surface with regards to its morphology, thermal variations during its irradiation in the pulp chamber and its increased resistance to demineralization through quantitative analysis of calcium and phosphorous atoms reactive concentrations in samples. Twenty samples of bovine enamel were used and divided in four groups: control - acidulated phosphate fluoride (APF) application followed by demineralization treatment with lactic acid; irradiation with Ho:YLF laser (100 J/cm 2 ) followed by APF topic application and demineralization treatment with lactic acid; irradiation with Ho:YLF laser (350 J/cm 2 ) followed by APF topic application and demineralization treatment with lactic acid: and irradiation with Ho:YLF laser ( 450 J/cm 2 ) followed by APF topic application and demineralization treatment with lactic acid. Ali samples were quantified according to their calcium and phosphorous atoms relative concentrations before and after the treatments above. X-Ray fluorescence spectrochemical analysis and scanning electron microscopy were carried out. It was observed an increase on the calcium and phosphorous atoms concentration ratio and therefore the enamel demineralization reduction as a result of the lactic acid treatment in the samples irradiated with the holmium laser followed by the APF application. In order to evaluate the feasibility of this study for clinical purposes, morphological changes caused by the holmium laser irradiation were analyzed. Such modifications were characterized by melted and re-solidified regions of the enamel with consequent changes on its permeability and solubility. Temperature changes of ten human pre-molars teeth irradiated with 350 J/cm 2 and 450 J/cm 2 were also monitored in the pulp chamber in real time. Temperature increases over 4,20 C did not occur. The results obtained from this study along with the results from previous researches developed at

  19. Catalytic Copolymerization of Ethene and Carbon Monoxide on Nickel Complexes.

    Domhöver, Bernd; Kläui, Wolfgang; Kremer-Aach, Andreas; Bell, Ralf; Mootz, Dietrich

    1998-11-16

    Can palladium be replaced by nickel? For the industrial copolymerization of carbon monoxide and ethene a palladium catalyst is used which cannot be recovered-a cheaper procedure would be desirable. The presented complex 1 is the first structurally characterized nickel compound which does not polymerize ethene but a mixture from carbon monoxide and ethene unter mild conditions to give a perfectly alternating polyketone. © 1998 WILEY-VCH Verlag GmbH, Weinheim, Fed. Rep. of Germany.

  20. Carbon monoxide and coronary heart disease

    Scheidemandel, V

    1974-01-01

    Studies on the relationship between increased carboxyhemoglobin levels in the blood and coronary heart disease in smokers and city dwellers are reviewed. The evidence of myocardial infarction is significantly higher in smokers than in nonsmokers which is due, apart from nicotine which promotes coronary arteriosclerosis, to inhaled carbon monoxide which leads to increased carboxyhemoglobin levels and most likely plays a role in the risk of arteriosclerosis and the coronary heart disease. Apart from combining with hemoglobin, CO increases the circulation rate and the coronary blood flow, and reduces the coronary arteriovenous oxygen difference, which is indicative of a reduced rate of oxygen extraction by the myocardium against an increased myocardial oxygen demand. The reduction of the oxygen extraction correlates with the increased COHb level. Inhaled CO lowers the threshold of angina pectoris due to the reduced myocardial oxygen tension. Also, considerable reduction of the oxygen diffusion from the capillaries toward the mitochondria due to the combination of CO with myoglobin is observed. Chronically increased CO levels in the blood and tissues not only accelerate the development of arteriosclerosis, but also induce a process directly injurious to the myocardial metabolism. (Air Pollut. Abstr.)

  1. First-Principles Investigations on Europium Monoxide

    Wang, Hao

    2011-05-01

    Europium monoxide is both an insulator and a Heisenberg ferromagnet (Tc=69 K). In the present thesis, the author has investigated the electronic structure of different types of EuO by density functional theory. The on-site Coulomb interaction of the localized Eu 4f and 5d electrons, which is wrongly treated in the standard generalized gradient approximation method, is found to be crucial to obtain the correct insulating ground state as observed in experiments. Our results show that the ferromagnetism is stable under pressure, both hydrostatic and uniaxial. For both types of pressure an insulator-metal transition is demonstrated. Moreover, the experimentally observed insulator-metal transition in oxygen deficient and gadolinium-doped EuO is reproduced in our calculations for impurity concentrations of 6.25% and 25%. Furthermore, a 10- layer EuO thin film is theoretically predicted to be an insulator with a narrow band gap of around 0.08 eV, while the Si/EuO interface shows metallic properties with the Si and O 2p as well as Eu 5d bands crossing the Fermi level.

  2. Carbon Monoxide Hydrogenation on Ice Surfaces.

    Kuwahata, Kazuaki; Ohno, Kaoru

    2018-03-14

    We have performed density functional calculations to investigate the carbon monoxide hydrogenation reaction (H+CO→HCO), which is important in interstellar clouds. We found that the activation energy of the reaction on amorphous ice is lower than that on crystalline ice. In the course of this study, we demonstrated that it is roughly possible to use the excitation energy of the reactant molecule (CO) in place of the activation energy. This relationship holds also for small water clusters at the CCSD level of calculation and the two-layer-level ONIOM (CCSD : X3LYP) calculation. Generally, since it is computationally demanding to estimate activation energies of chemical reactions in a circumstance of many water molecules, this relationship enables one to determine the activation energy of this reaction on ice surfaces from the knowledge of the excitation energy of CO only. Incorporating quantum-tunneling effects, we discuss the reaction rate on ice surfaces. Our estimate that the reaction rate on amorphous ice is almost twice as large as that on crystalline ice is qualitatively consistent with the experimental evidence reported by Hidaka et al. [Chem. Phys. Lett., 2008, 456, 36.]. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Review: hemodynamic response to carbon monoxide

    Penney, D.G.

    1988-04-01

    Historically, and at present, carbon monoxide is a major gaseous poison responsible for widespread morbidity and mortality. From threshold to maximal nonlethal levels, a variety of cardiovascular changes occur, both immediately and in the long term, whose homeostatic function it is to renormalize tissue oxygen delivery. However, notwithstanding numerous studies over the past century, the literature remains equivocal regarding the hemodynamic responses in animals and humans, although CO hypoxia is clearly different in several respects from hypoxic hypoxia. Factors complicating interpretation of experimental findings include species, CO dose level and rate, route of CO delivery, duration, level of exertion, state of consciousness, and anesthetic agent used. Augmented cardiac output usually observed with moderate COHb may be compromised in more sever poisoning for the same reasons, such that regional or global ischemia result. The hypotension usually seen in most animal studies is thought to be a primary cause of CNS damage resulting from acute CO poisoning, yet the exact mechanism(s) remains unproven in both animals and humans, as does the way in which CO produces hypotension. This review briefly summarizes the literature relevant to the short- and long-term hemodynamic responses reported in animals and humans. It concludes by presenting an overview using data from a single species in which the most complete work has been done to date.

  4. Carbon monoxide measurements at Mace Head, Ireland

    Doddridge, Bruce G.; Dickerson, Russell R.; Spain, T. Gerard; Oltmans, Samuel J.; Novelli, Paul C.

    1994-01-01

    The North Atlantic Ocean is bordered by continents which may each, under the influence of seasonal weather patterns, act as sources of natural and anthropogenic trace gas and particulate species. Photochemically active species such as carbon monoxide (CO) react to form ozone (O3), a species of critical importance in global climate change. CO is sparingly soluble in water, and the relatively long lifetime of CO in the troposphere makes this species an ideal tracer of air masses with origin over land. We have measured CO using a nondispersive infrared gas filter correlation analyzer at Mace Head on the west coast of Ireland nearly continuously since August 9, 1991. Measurements of CO were acquired at 20-sec resolution and recorded as 60-sec averages. Daily, monthly, and diurnal variation data characteristics of CO mixing ratios observed at this site are reported. Depending on source regions of air parcels passing over this site, 60-min concentrations of CO range from clean air values of approximately 90 ppbv to values in excess of 300 ppbv. Data characterizing the correlation between 60-min CO and O3 mixing ratio data observed at this site are reported also.

  5. Residential carbon monoxide poisoning from motor vehicles.

    Hampson, Neil B

    2011-01-01

    Although morbidity and mortality from accidental carbon monoxide (CO) poisoning are high in the United States, identification of common but poorly recognized sources should help prevention efforts. The study aimed to describe CO poisoning of home occupants due to a vehicle left running in an attached garage. News stories reporting incidents of US CO poisoning were collected daily from March 2007 to September 2009 via a news.Google.com search and data extracted. Patients were individuals reported in the media to have been poisoned with CO in their home by a vehicle running in the attached garage. Main outcome measures were frequency of occurrence, geographic distribution, patient demographics, and mortality. Of 837 CO poisoning incidents reported in US news media over 2 and a half years, 59 (8%) were the result of a vehicle left running in the garage. The elderly were disproportionately affected, with incidents most common in states with larger elderly populations and 29% of cases with age specified occurring in individuals older than 80 years. Among those older than 80 years, 15 of 17 were found dead at the scene. Residential CO poisoning from a vehicle running in the garage is common, disproportionately affects the elderly, has a high mortality rate, and should be preventable with a residential CO alarm. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Carbon Monoxide: An Essential Signalling Molecule

    Mann, Brian E.

    Carbon monoxide (CO), like nitric oxide (NO), is an essential signalling molecule in humans. It is active in the cardiovascular system as a vasodilator. In addition, CO possesses anti-inflammatory, anti-apoptotic and anti-proliferative properties and protects tissues from hypoxia and reperfusion injury. Some of its applications in animal models include suppression of organ graft rejection and safeguarding the heart during reperfusion after cardiopulmonary bypass surgery. CO also suppresses arteriosclerotic lesions following angioplasty, reverses established pulmonary hypertension and mitigates the development of post-operative ileus in the murine small intestine and the development of cerebral malaria in mice as well as graft-induced intimal hyperplasia in pigs. There have been several clinical trials using air-CO mixtures for the treatment of lung-, heart-, kidney- and abdominal-related diseases. This review examines the research involving the development of classes of compounds (with particular emphasis on metal carbonyls) that release CO, which could be used in clinically relevant conditions. The review is drawn not only from published papers in the chemical literature but also from the extensive biological literature and patents on CO-releasing molecules (CO-RMs).

  7. Elevated carboxyhemoglobin: sources of carbon monoxide exposure.

    Buchelli Ramirez, Herminia; Fernández Alvarez, Ramón; Rubinos Cuadrado, Gemma; Martinez Gonzalez, Cristina; Rodriguez Jerez, Francisco; Casan Clara, Pere

    2014-11-01

    Inhalation of carbon monoxide (CO) can result in poisoning, with symptoms ranging from mild and nonspecific to severe, or even death. CO poisoning is often underdiagnosed because exposure to low concentrations goes unnoticed, and threshold values for normal carboxyhemoglobin vary according to different authors. The aim of our study was to analyze carboxyhemoglobin (COHb) levels in an unselected population and detect sources of CO exposure In a cross-sectional descriptive study, we analyzed consecutive arterial blood gas levels processed in our laboratory. We selected those with COHb≥2.5% in nonsmokers and ≥5% in smokers. In these cases a structured telephone interview was conducted. Elevated levels of COHb were found in 64 (20%) of 306 initial determinations. Of these, data from 51 subjects aged 65±12 years, 31 (60%) of which were men, were obtained. Mean COHb was 4.0%. Forty patients (78%) were non-smokers with mean COHb of 3.2%, and 11 were smokers with COHb of 6.7%. In 45 patients (88.2%) we detected exposure to at least one source of ambient CO other than cigarette smoke. A significant proportion of individuals from an unselected sample had elevated levels of COHb. The main sources of CO exposure were probably the home, so this possibility should be explored. The population should be warned about the risks and encouraged to take preventive measures. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.

  8. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ......) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers....

  9. Hyperfine-Interaction-Driven Suppression of Quantum Tunneling at Zero Field in a Holmium(III) Single-Ion Magnet.

    Chen, Yan-Cong; Liu, Jun-Liang; Wernsdorfer, Wolfgang; Liu, Dan; Chibotaru, Liviu F; Chen, Xiao-Ming; Tong, Ming-Liang

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm -1 . The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from 165 Ho (I=7/2) with a natural abundance of 100 %. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Hyperfine-interaction-driven suppression of quantum tunneling at zero field in a holmium(III) single-ion magnet

    Chen, Yan-Cong; Liu, Jun-Liang; Chen, Xiao-Ming; Tong, Ming-Liang [Key Lab. of Bioinorganic and Synthetic Chemistry of Ministry of Education, School of Chemistry, Sun Yat-Sen Univ., Guangzhou (China); Wernsdorfer, Wolfgang [Institut Neel, CNRS and Universite Joseph Fournier, Grenoble (France); Institute of Nanotechnology, Karlsruhe Institute of Technology (Germany); Physikalisches Institut, Karlsruhe Institute of Technology (Germany); Liu, Dan; Chibotaru, Liviu F. [Theory of Nanomaterials Group and INPAC-Institute of Nanoscale Physics and Chemistry, Katholieke Universiteit Leuven (Belgium)

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm{sup -1}. The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from {sup 165}Ho (I=7/2) with a natural abundance of 100 %. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Solar cycle variations in mesospheric carbon monoxide

    Lee, Jae N.; Wu, Dong L.; Ruzmaikin, Alexander; Fontenla, Juan

    2018-05-01

    As an extension of Lee et al. (2013), solar cycle variation of carbon monoxide (CO) is analyzed with MLS observation, which covers more than thirteen years (2004-2017) including maximum of solar cycle 24. Being produced primarily by the carbon dioxide (CO2) photolysis in the lower thermosphere, the variations of the mesospheric CO concentration are largely driven by the solar cycle modulated ultraviolet (UV) variation. This solar signal extends down to the lower altitudes by the dynamical descent in the winter polar vortex, showing a time lag that is consistent with the average descent velocity. To characterize a global distribution of the solar impact, MLS CO is correlated with the SORCE measured total solar irradiance (TSI) and UV. As high as 0.8 in most of the polar mesosphere, the linear correlation coefficients between CO and UV/TSI are more robust than those found in the previous work. The photochemical contribution explains most (68%) of the total variance of CO while the dynamical contribution accounts for 21% of the total variance at upper mesosphere. The photochemistry driven CO anomaly signal is extended in the tropics by vertical mixing. The solar cycle signal in CO is further examined with the Whole Atmosphere Community Climate Model (WACCM) 3.5 simulation by implementing two different modeled Spectral Solar Irradiances (SSIs): SRPM 2012 and NRLSSI. The model simulations underestimate the mean CO amount and solar cycle variations of CO, by a factor of 3, compared to those obtained from MLS observation. Different inputs of the solar spectrum have small impacts on CO variation.

  12. Eesti seep saab hoo sisse / Maria Ulfsak

    Ulfsak, Maria, 1981-

    2003-01-01

    Kanal 2s algab uus kodumaine komöödiasari "Õpetajate tuba", mille käsikiri on Peep Pedmansonilt, lavastus Ivo Eensalult, näitlejad on Ita Ever, Eino Baskin, Madis Milling, Henrik Normann, Maria Klenskaja, Margus Tabor jt., tootjafirmaks "Ruut"

  13. Hyperfine structure investigation of the first excited state 4Isub(13/2) (5,418-1) in Holmium-165 by the atomic beam resonance method

    Aldenhoven, R.

    1976-01-01

    By the method of atomic beam resonance the hyperfine structure of the first excited state 4 Isub(13/2) (5418 cm -1 ) of 165 Holmium was studied for the first time. Using a suitable ΔF = 0 transition, the gsub(J)-factor was measured. After a determination of estimates for the hyperfine constants A and B from two suitably chosen ΔF = 0 transitions, the hyperfine splittings have been measured. (orig./WL) [de

  14. The effect and influence of lumen holmium laser lithotripsy on serum oxidative stress proteins and inflammatory factors of ureteral calculi patients

    Fan Zhang

    2016-09-01

    Full Text Available Objective: To investigate the effect and influence of lumen holmium laser lithotripsy on treating serum oxidative stress proteins and inflammatory factors of patients with ureteral calculi. Methods: A total of 120 cases of patients with ureteral calculi treated in our hospital from May 2010 to Nov 2014 were enrolled in this research for an analysis study. The effect and influence on serum oxidative stress proteins and inflammatory factors of lumen holmium laser lithotripsy on ureteral calculi patients were assayed. Then 120 cases of healthy subjects in our hospital at the same period were taken as control. Results: Among the 120 cases of ureteral calculi patients, 113 cases of patients showed successful operation, with a success rate of 94.2%. The average calculi-discharged time was (28.4 ± 11.2 d and the average operation time was (58.9 ± 10.7 min, while the postoperative hospital stay is (3.8 ± 1.2 d. The results also showed that the levels of NOX1. NOX3, NOX4 and NOX5, and levels of interleukin-2 (IL-2, IL-6, IL-10 and TNF-α of patients with ureteral calculi were significantly higher, compared with the control group, and these parameters were normalized greatly after operation with that the levels of them were significantly different from those before operation. Conclusion: Lumen holmium laser lithotripsy exerts a significant effect on ureteral calculi patients and the oxidative stress parameters and inflammatory factor were normalized greatly.

  15. Outcome analysis of holmium laser and pneumatic lithotripsy in the endoscopic management of lower ureteric calculus in pediatric patients: a prospective study

    Ankur Jhanwar

    Full Text Available ABSTRACT Objective: To analyse outcomes of holmium laser and pneumatic lithotripsy in treatment of lower ureteric calculus in pediatric patients. Materials and methods: Prospective study conducted between August 2013 and July 2015. Inclusion criteria were lower ureteric calculus with stone size ≤1.5cms. Exclusion criteria were other than lower ureteric calculus, stone size ≥1.5cms, congenital renal anomalies, previous ureteral stone surgery. Patients were divided into two groups. Group A underwent pneumatic and group B underwent laser lithotripsy procedure. Patient's baseline demographic and peri-operative data were recorded and analysed. Post operatively X-ray/ultrasound KUB (Kidney, ureter and bladder was performed to assess stone free status. Results: A total of 76 patients who met the inclusion criteria to ureteroscopic intracorporeal lithotripsy were included. Group A and B included 38 patients in each. Mean age was 12.5±2.49 in Group A and 11.97±2.74 years in Group B respectively (p=0.38. Overall success rate was 94.73% in Group A and 100% in Group B, respectively (p=0.87. Conclusion: Holmium Laser lithotripsy is as efficacious as pneumatic lithotripsy and can be used safely for the endoscopic management of lower ureteric calculus in pediatric patients. However, holmium laser requires more expertise and it is a costly alternative.

  16. Carbon monoxide poisoning from waterpipe smoking: a retrospective cohort study.

    Eichhorn, Lars; Michaelis, Dirk; Kemmerer, Michael; Jüttner, Björn; Tetzlaff, Kay

    2018-04-01

    Waterpipe smoking may increasingly account for unintentional carbon monoxide poisoning, a serious health hazard with high morbidity and mortality. We aimed at identifying waterpipe smoking as a cause for carbon monoxide poisoning in a large critical care database of a specialty care referral center. This retrospective cohort study included patients with a history of exposure to waterpipe smoking and carbon monoxide blood gas levels >10% or presence of clinical symptoms compatible with CO poisoning admitted between January 2013 and December 2016. Patients' initial symptoms and carbon monoxide blood levels were retrieved from records and neurologic status was assessed before and after hyperbaric oxygen treatment. Sixty-one subjects with carbon monoxide poisoning were included [41 males, 20 females; mean age 23 (SD ± 6) years; range 13-45] with an initial mean carboxyhemoglobin of 26.93% (SD ± 9.72). Most common symptoms included syncope, dizziness, headache, and nausea; 75% had temporary syncope. Symptoms were not closely associated with blood COHb levels. CO poisoning after waterpipe smoking may present in young adults with a wide variability of symptoms from none to unconsciousness. Therefore diagnosis should be suspected even in the absence of symptoms.

  17. Carbon monoxide and COHb concentration in blood in various circumstances

    Modic, J. [Faculty of Mechanical Engineering, University of Ljubljana, Ljubljana (Slovenia)

    2003-07-01

    On the basis of known medical experiments we find out the correlation between the concentration of carbon monoxide (CO) in inhaling air and the concentration of carboxihemoglobyne (COHb) in human blood. All internal combustion engines produce exhaust gases containing noxious compounds: carbon monoxide, nitrogen oxides (NO{sub x}), carbon oxides (CxHy) and smoke. In a living room is important the smoke of cigarettes, smoke of furnaces, improper ventilation. In tunnel is most dangerous the carbon monoxide if it exceeds an allowable level. In human blood the carbon monoxide causes increasing the concentration of carboxihemoglobyne and in this case the hypoxia of web. With help of mathematical model the concentrations of some dangerous substances at the end of tunnel were calculated. For this case a differential equation also was developed and it shows the correlation between concentration of carbon monoxide in the air and concentration of carboxihemoglobyne in the blood. The constructed mathematical model shows circumstances in the tunnel (velocity of air moving as effect of induction, concentration of noxious substances and criterial number). Also a corresponding computer program was developed, which makes possible a quick and simple calculation. All the results are proved by experiments. Finally the differential equation was done, which shows a temporal connection between both parameters as a function of tunnel characteristics. (author)

  18. New reduced variant in gadolinium and samarium monoxide thin films

    Bist, B M.S.; Kumar, J; Srivastava, O N [Banaras Hindu Univ. (India). Dept. of Physics

    1977-01-01

    A new reduced phase has been observed in the thin films of gadolinium and samarium monoxides. This phase results on imparting an annealing treatment to the monoxides and is formed as a result of the creation and ordering of vacancies in the oxygen sublattice. The new phase has been analysed to possess a rhombohedral unit cell with lattice parameters a/sub R/ = a/sub 0/ square root of (3/2) and c/sub R/ = a/sub 0/ square root of 3 (based on hexagonal axes, a/sub 0/ being the lattice parameter of the fundamental zinc blende type unit cell of the monoxide). Based on the proposed structure, the new phase can be assigned the solid state chemical formula RO/sub x/ where R = Gd, Sm and x = 0.66.

  19. Development of an enzymatic sensor for carbon monoxide

    Hurtado, Clara; Gomez, Diana; Larmat, Fernando; Torres, Walter; Cuervo, Raul; Bravo, Enrique; Benitez, Neyla

    2003-01-01

    The detection and the pursuit of gases that contribute in the increase of the atmospheric contamination are a necessity, for what the electrochemical sensors have potential industrial applications for the control of the quality of the air. The development of amperometric sensor based on enzymes offers advantages, since the use of the biological component provides him high selectivity due to the great specificity of the substrate of the enzyme. The monoxide of carbon (CO) it is a polluting, poisonous gas, taken place during the incomplete combustion of organic materials (natural gas, petroleum, gasoline, coal and vegetable material). The determination of monoxide of carbon (CO) it can be reached by electrochemical mediums using the methylene blue like the electronic mediator for the enzyme monoxide of carbon oxidase (COx)

  20. Terpolymerization of ethylene, sulfur dioxide and carbon monoxide

    Johnson, R.; Steinberg, M.

    This invention relates to high molecular weight terpolymer of ethylene, sulfur dioxide and carbon monoxide stable to 280/sup 0/C and containing as little as 36 mo1% ethylene and about 41 to 51 mo1% sulfur dioxide, and to the method of producing said terpolymer by irradiation of a liquid and gaseous mixture of ethylene, sulfur dioxide and carbon monoxide by means of Co-60 gamma rays or an electron beam, at a temperature of about 10 to 50/sup 0/C, and at a pressure of about 140 to 680 atmospheres, to initiate polymerization.

  1. Modeling chemisorption kinetics of carbon monoxide on polycrystalline platinum

    Donnelly, R.G.; Modell, M.; Baddour, R.F.

    1978-04-01

    Seven distinct desorption surface states of carbon monoxide on polycrystalline platinum were detected by deconvoluting temperature-programed desorption spectra of 4-100% carbon monoxide monolayer coverage. The adstates had fixed activation energies of desorption (22.5-32.6 kcal/mole) over the entire coverage range. Rates of formation and populations were derived. The chemisorption was modeled by a Hinshelwood-type expression which allowed for site creation and suggested that adsorbed molecules are sufficiently mobile during desorption heating to fill ordered states of minimum energy and that chemisorption into these states is noncompetitive and determined by the surface. Spectra, diagrams, graphs, tables, and 49 references.

  2. Evaluation of erbium:YAG and holmium:YAG laser radiation and dental hard tissue

    Attrill, David Cameron

    Lasers have become increasingly established in medicine as effective alternatives or adjuncts to conventional techniques. In dentistry, several clinical laser systems have been developed and marketed, but their applications have been limited to soft tissue surgery. To date, no laser has been capable of effectively cutting or modifying the highly mineralised dental tissues of enamel and dentine. The aim of this study was to evaluate two new laser systems for use in dentistry through a series of in vitro experiments. Both generic erbium and holmium lasers have theoretically superior operating characteristics over currently established lasers for applications with dental hard tissues. The two lasers investigated in this study were pulsed Er:YAG (lambda=2.94) a.m. and Cr-Tm-Ho:YAG (lambda=2.1mu.m). Both operated with a macropulse duration of approximately 200lambdas, at pulse repetition rates of 2-8Hz and mean pulse energies up to 230mJ. Radiation was focused using CaF[2] lenses (f=50-120mm). The lasers could be operated with or without the addition of a surface water film at the interaction site. Tissue removal efficiency was expressed as a latent heat of ablation (LHA, kJ/cm[3]) using a modification of the technique described by Charlton et al. (1990). The mean LHA's for the Er:YAG laser were 6.24kJ/cm[3] and 22.99kJ/cm[3] with dentine and enamel respectively without water, and 10.07kJ/cm[3] and 18.73kJ/cm[3] for dentine and enamel with water. The Cr-Tm-Ho:YAG laser was unable to effectively remove enamel at the fluences and pulse energies available; the mean LHA's for the Cr-Tm- Ho:YAG laser with dentine were 82.79kJ/cm3 and 57.57kJ/cm3 with and without water respectively. The Cr-Tm-Ho;YAG was approximately 8-9 times less efficient for tissue removal than the Er:YAG system. Er:YAG tissue removal with water was characterised by clean "surgical" cuts, comparable in histological appearance to those obtained using conventional instrumentation. Some thermal disruption

  3. Optimization of Treatment Policy for Acute Carbon Monoxide Poisoning

    R. N. Akalayev

    2012-01-01

    Full Text Available Objective: to evaluate the efficiency of combination use of hyperbaric oxygenation, succinate-containing solutions, and anti-edematous agents in patients with acute carbon monoxide poisoning. Subjects and methods. The results of treatment were analyzed in 32 patients admitted in 2009—2011 for severe acute carbon monoxide poisoning and a Glasgow coma score of 6—8. The patients were divided into 2 groups: 1 patients whose combination therapy involved hyperbaric oxygenation, Succinasol infusions, and L-lysine-aescinate injections; 2 those who received traditional therapy. All the patients underwent complex clinical, laboratory, and neurophysiologic examinations. Results. Just 24 hours after the combination use of Succinasol and L-lysine-aescinate, Group I patients were observed to have substantially reduced lactate, the content of the latter approached the normal value following 48 hours, which was much below the values in the control group. The similar pattern was observed when endogenous intoxication parameters were examined. During the performed therapy, the level of consciousness and that of intellect according to the MMSE and FAB scales were restored more rapidly in the study group patients than in Group 2. Conclusion. The combination use of hyperbaric oxygenation, the succinate-containing solution Succinasol, and the anti-edematous agent L-lysine-aescinate considerably enhances the efficiency of intensive therapy for acute carbon monoxide poisoning. Key words: carbon monoxide, toxic hypoxic encephalopathy, combination therapy, hyperbaric oxygenation, succinic acid, L-lysine-aescinate.

  4. Production of Ethylene and Carbon Monoxide by Microorganisms

    T. H. Filer; L. R. Brown; S. Brown-Sarobot; S. Martin

    1984-01-01

    Various quantities of ethylene and carbon monoxide were produced on PDA by Fusicladium effusum, Pestilotia nucicola, Alternaria tenuis, and Fusarium oxysporum subcultured from diseased pecan shucks. Repeated subculturing of these fungi on potato dextrose broth supplemented with iron powder produced ethylene. The production of...

  5. Ethylene and Carbon Monoxide Production by Septoria musiva

    S. Brown-Skrobot; L. R. Brown; T. H. Filer

    1984-01-01

    An investigation into the mechanism by which Septoria musiva causes the premature defoliation of cottonwood trees was undertaken. Gas-chromatograpic analysis of the atmosphere overlying the original culture indicated that this fungus produced significant quantities of ethylene and carbon monoxide. Subcultures failed to produce either gas on a variety...

  6. Poisoning by carbon monoxide in Morocco from 1991 to 2008.

    Aghandous, Rachida; Chaoui, Hanane; Rhalem, Naima; Semllali, Ilham; Badri, Mohamed; Soulaymani, Abdelmajid; Ouammi, Lahcen; Soulaymani-Bencheikh, Rachida

    2012-04-01

    To describe the characteristics relating to the provenance of statements, patients and to evaluate the spatiotemporal evolution of carbon monoxide poisoning reported to Poison Control Center and Pharmacovigilance of Morocco (CAPM). This is a retrospective study over a period of 18 years from 1991 to 2008, for all cases of poisoning by carbon monoxide reported to CAPM. The epidemiological study focused on 12 976 cases of carbon monoxide poisoning reported to CAPM between 1991 and 2008. The average age of patients was 25.5 +/- 15.6 years, sex ratio was 0.5. The poisoning occurred by accident in 98.7% of cases, especially at home (96.7%) and in cold months. The urban population was the most affected (89.0%). The region of Meknes Tafilalt was the most concerned with 16.6% of cases. The symptomatology was characterized by the predominance of gastrointestinal tract diseases (37.1%). Deaths have reached a percentage of 0.9%. These qualitative and quantitative information is useful to highlight warnings and plan a strategy against carbon monoxide poisoning in Morocco.

  7. Pathways and bioenergetics of anaerobic carbon monoxide fermentation

    Diender, Martijn; Stams, Fons; Machado de Sousa, Diana

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the

  8. [Cerebellar Infarction After Carbon Monoxide Poisoning and Hyperbaric Oxygen Therapy].

    Wick, Matthias; Schneiker, André; Bele, Sylvia; Pawlik, Michael; Meyringer, Helmut; Graf, Bernhard; Wendl, Christina; Kieninger, Martin

    2017-06-01

    We report on a patient who developed a space-occupying cerebellar infarction with occlusive hydrocephalus after a poisoning with carbon monoxide with the intention to commit suicide. A neurosurgical and intensive care therapy were needed. The patient's survival without severe neurological deficits could be secured due to the early detection of the intracerebral lesions. Georg Thieme Verlag KG Stuttgart · New York.

  9. Carbon Monoxide Poisoning in a Child: A Case Report | Asani ...

    The exact incidence of carbon monoxide (CO) poisoning in Nigeria is unknown. Globally, CO poisoning is frequently unrecognized and under-reported since the clinical presentation is relatively non-specific. The circumstances usually involve an unsuspected increase of CO in an enclosed environment. We present the ...

  10. Predictive risk factors of postoperative urinary incontinence following holmium laser enucleation of the prostate during the initial learning period

    Shuichiro Kobayashi

    Full Text Available ABSTRACT Purpose: To determine the predictive factors for postoperative urinary incontinence (UI following holmium laser enucleation of the prostate (HoLEP during the initial learning period. Patients and Methods: We evaluated 127 patients with benign prostatic hyperplasia who underwent HoLEP between January 2011 and December 2013. We recorded clinical variables, including blood loss, serum prostate-specific antigen levels, and the presence or absence of UI. Blood loss was estimated as a decline in postoperative hemoglobin levels. The predictive factors for postoperative UI were determined using a multivariable logistic regression analysis. Results: Postoperative UI occurred in 31 patients (24.4%, but it cured in 29 patients (93.5% after a mean duration of 12 weeks. Enucleation time >100 min (p=0.043 and blood loss >2.5g/dL (p=0.032 were identified as significant and independent risk factors for postoperative UI. Conclusions: Longer enucleation time and increased blood loss were independent predictors of postoperative UI in patients who underwent HoLEP during the initial learning period. Surgeons in training should take care to perform speedy enucleation maneuver with hemostasis.

  11. Line Identification of Atomic and Ionic Spectra of Holmium in the Near-UV. Part I. Spectrum of Ho i

    Al-Labady, N.; Özdalgiç, B. [Graduate School of Engineering and Sciences, Istanbul University, TR-34452 Beyazıt, Istanbul (Turkey); Er, A.; Güzelçimen, F.; Öztürk, I. K.; Başar, Gö. [Faculty of Science, Department of Physics, Istanbul University, TR-34134 Vezneciler, Istanbul (Turkey); Kröger, S. [Hochschule für Technik und Wirtschaft Berlin, Wilhelminenhofstr. 75A, D-12459 Berlin (Germany); Kruzins, A.; Tamanis, M.; Ferber, R., E-mail: ikanat@istanbul.edu.tr [Laser Centre, The University of Latvia, Rainis Boulevard 19, LV-1586 Riga (Latvia)

    2017-02-01

    The Fourier Transform spectra of a Holmium hollow cathode discharge lamp have been investigated in the UV spectral range from 25,000 up to 31,530 cm{sup −1} (317 to 400 nm). Two Ho spectra have been measured with neon and argon as buffer gases. Based on the intensity ratios from these two spectra, a distinction was made between atomic and ionic lines (ionic lines are discussed in an accompanying paper). Using the known Ho i energy levels, 71 lines could be classified as transitions of atomic Ho, 34 of which have not been published previously. Another 32 lines, which could not be classified, are listed in the literature and assigned as atomic Ho. An additional 370 spectral lines have been assigned to atomic Ho based on the signal-to-noise ratio in the two spectra measured under different discharge conditions, namely with buffer gases argon and neon, respectively. These 370 lines have not been previously listed in the literature.

  12. Spectroscopic studies of the energy transfer processes important to obtain holmium laser action in the Er:Tm:Ho:YLF

    Tarelho, Luiz Vicente Gomes

    1995-01-01

    There are several processes of energy transfer between Er, Tm and Ho ions in YLF crystal that could be evaluated using the Foerster-Dexter method. Energy transfer processes, important to understand Holmium laser action, were studied, specially involving the energy transfer between the first excited states of Er and Tm donors and Ho acceptor. The back-transfer processes were evaluated too in order to minimize the system losses. Another important process to understand Ho laser action in the host is the energy diffusion mechanism between donor ions due to excitation migration processes which take place before the energy transfer to Ho. The proposed model of energy transfer was developed to include the diffusion mechanism between donors in the absence and presence of the acceptors. The energy transfer probability was evaluated including the back-transfer processes besides the diffusion assistance. A laser medium model based on the fundamental spectroscopic parameters was used in order to determine the ideal donor acceptor concentrations in order to maximize the laser action of Ho at 2,1 μm. (author)

  13. Influence of Pelvicaliceal Anatomy on Stone Clearance After Flexible Ureteroscopy and Holmium Laser Lithotripsy for Large Renal Stones.

    Inoue, Takaaki; Murota, Takashi; Okada, Shinsuke; Hamamoto, Shuzo; Muguruma, Kouei; Kinoshita, Hidefumi; Matsuda, Tadashi

    2015-09-01

    This study was performed to evaluate the impact of pelvicaliceal anatomy on stone clearance in patients with remnant fragments in the lower pole after flexible ureteroscopy and holmium laser lithotripsy (fURSL) for renal stones >15 mm. This retrospective study included 67 patients with radiopaque residual fragments (>2 mm) in the lower pole after fURSL for large renal stones (>15 mm). The preoperative infundibular length (IL), infundibular width (IW), infundibulopelvic angle (IPA), and caliceal pelvic height (CPH) were measured using intravenous urography. Multivariate analysis was performed to determine whether any of these measurements affected stone clearance. Of the 67 patients, 55 (82.1%) were stone free (SF) 3 months after fURSL. The anatomic factors significantly favorable for an SF status were a short IL, broad IW, wide IPA, and low CPH. On multivariate analysis, the IPA had a significant influence on an SF status after fURSL (p=0.010). An IPA renal stones according to our multivariate analysis. Additional studies are required to further evaluate the characteristics of the pelvicaliceal anatomy influencing stone clearance.

  14. Brachytherapy using holmium-166 liquid balloon system for in-stent restenosis: 6 months clinical and angiographic follow-up

    Kim, M. H.; Kim, S. K.; Cha, K. S.; Kim, Y. D.; Lee, H. S.; Kang, D. Y. [Donga University College of Medicine, Busan (Korea, Republic of)

    2002-07-01

    In western country, 3 systems of brachytherapy using commercial radioactive source has been established. However, brachytherapy using holmium-166 liquid balloon system (HLBS) for the patient with stent restenosis has not been studied enough. 30 patients (male 23, mean age 58.9 7.7) were enrolled. Target dose was 15 Gy at 1 mm distance from the intimal surface. Clinical diagnoses of the study patients included stable angina 10 and unstable angina 20 patients. Target lesion included LAD 19, LCx 5 and RCA 6 arteries. Pre-brachytherapy treatment included cutting balloon angioplasty in 25, rotational atherectomy in 5 patients. Fractionation and stepping was done in 6 patients each. Follow-up angiography was done in 19 patients. Of them, 4 cases developed angiographic restenosis (21%) including 3 cases of total occlusion. 6 month MACE (major adverse cardiac event) occurred in 5 patients including one sudden cardiac death in a patient with 80 year-old, triple-vessel diseased patient. Vascular brachytherapy using HLBS is a safe and effective treatment modality for in-stent restenosis showing acceptable angiographic and clinical result.

  15. Rebuttal of the existence of solid rare earth bicarbonates and the crystal structure of holmium nitrate pentahydrate

    Rincke, Christine; Schmidt, Horst; Voigt, Wolfgang [Institute for Inorganic Chemistry, TU Bergakademie Freiberg (Germany)

    2017-03-16

    The synthesis routes of Gd(HCO{sub 3}){sub 3}.5H{sub 2}O and Ho(HCO{sub 3}){sub 3}.6H{sub 2}O, which are the only known bicarbonates of rare earth metals, were refuted and the published crystal structures were discussed. Because of the structural relationship of Ho(HCO{sub 3}){sub 3}.6H{sub 2}O to rare earth nitrate hexahydrates,[] the synthesis of holmium nitrate hydrate was considered and the crystal structure of Ho(NO{sub 3}){sub 3}.5H{sub 2}O was solved by single crystal X-ray diffraction measurements. Ho(NO{sub 3}){sub 3}.5H{sub 2}O was determined to crystallize in the triclinic space group P1 (no. 2) with a = 6.5680(14) Aa, b = 9.503(2) Aa, c = 10.462(2) Aa, α = 63.739(14) , β = 94.042(2) and γ = 76.000(16) . The crystal structure consists of isolated [Ho(H{sub 2}O){sub 4}(NO{sub 3}){sub 3}] polyhedra and non-coordinating water molecules. It is isotypic to other rare earth nitrate pentahydrates. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. The Impact of Increased Bladder Blood Flow on Storage Symptoms after Holmium Laser Enucleation of the Prostate.

    Keisuke Saito

    Full Text Available In order to investigate how holmium laser enucleation of the prostate (HoLEP improves urinary storage symptoms, we assessed blood flow in the urinary bladder mucosa of patients with benign prostatic hyperplasia (BPH before and after laser surgery. Seventy-four consecutive patients with BPH (median age 69 years, range; 53-88 underwent HoLEP at our institution and are included in this study. We prospectively assessed the International Prostate Symptom Score (IPSS, IPSS-QOL Score, the Overactive Bladder Symptom Score (OABSS, uroflowmetry, and blood flow in the urinary bladder, before and after surgery. Blood flow in the bladder mucosa was measured using the OMEGA FLOW (OMEGAWAVE, Tokyo, Japan laser Doppler flowmeter. The median volume of the enucleated adenomas was 45.0 g (range: 25.0 to 83.2. The median IPSS improved significantly from 20 (range: 6-35 to 3 (0-22 (p < 0.001; Wilcoxon signed-rank test, as did the storage symptoms score, which decreased from 13 (2-20 to 3 (1-8 (p < 0.001. Median bladder blood flow increased at the trigone from 9.57 ± 0.83 ml/sec to 17.60 ± 1.08 ml/sec. Multiple regression analysis for the improved storage symptom score eliminated all explanatory variables except increased bladder perfusion. The data suggest that HoLEP improves blood flow in the bladder mucosa, which independently leads to the improvement of storage symptoms.

  17. The Impact of Increased Bladder Blood Flow on Storage Symptoms after Holmium Laser Enucleation of the Prostate

    Ide, Hisamitsu; Aoki, Hiroaki; Muto, Satoru; Yamaguchi, Raizo; Tsujimura, Akira; Horie, Shigeo

    2015-01-01

    In order to investigate how holmium laser enucleation of the prostate (HoLEP) improves urinary storage symptoms, we assessed blood flow in the urinary bladder mucosa of patients with benign prostatic hyperplasia (BPH) before and after laser surgery. Seventy-four consecutive patients with BPH (median age 69 years, range; 53–88) underwent HoLEP at our institution and are included in this study. We prospectively assessed the International Prostate Symptom Score (IPSS), IPSS-QOL Score, the Overactive Bladder Symptom Score (OABSS), uroflowmetry, and blood flow in the urinary bladder, before and after surgery. Blood flow in the bladder mucosa was measured using the OMEGA FLOW (OMEGAWAVE, Tokyo, Japan) laser Doppler flowmeter. The median volume of the enucleated adenomas was 45.0 g (range: 25.0 to 83.2). The median IPSS improved significantly from 20 (range: 6–35) to 3 (0–22) (p<0.001; Wilcoxon signed-rank test), as did the storage symptoms score, which decreased from 13 (2–20) to 3 (1–8) (p<0.001). Median bladder blood flow increased at the trigone from 9.57±0.83 ml/sec to 17.60±1.08 ml/sec. Multiple regression analysis for the improved storage symptom score eliminated all explanatory variables except increased bladder perfusion. The data suggest that HoLEP improves blood flow in the bladder mucosa, which independently leads to the improvement of storage symptoms. PMID:26090819

  18. Comparison of cold-knife optical internal urethrotomy and holmium:YAG laser internal urethrotomy in bulbar urethral strictures

    Yenice, Mustafa Gurkan; Sam, Emre; Colakoglu, Yunus; Atar, Feyzi Arda; Sahin, Selcuk; Simsek, Abdulmuttalip; Tugcu, Volkan

    2017-01-01

    Introduction To compare the results of cold-knife optical internal urethrotomy (OIU) and Holmium:YAG laser internal urethrotomy (HIU) in primary bulbar urethral strictures. Material and methods A total of 63 patients diagnosed with primary bulbar urethral stricture between August 2014 and September 2015 were assigned to the OIU (n = 29) and HIU (n = 34) groups. The demographic variables, biochemistry panels, and preoperative and postoperative uroflowmetry results including the maximum flow rate (Qmax) and mean flow rate (Qmean) values, retrograde urethrography, and diagnostic flexible urethroscopy findings were recorded prospectively. Demographic features and preoperative values were not statistically different between groups (p >0.05). Mean surgical times were 18.4 ±2.3 min for OIU and 21.9 ±3.8 min for HIU groups, which was statistically significant (p 0.05). There was no recurrence in the first 3 months in either group. The urethral stricture recurrence rate up to month 12 was not statistically significant for the OIU group (n = 6, 20.7%) as compared to the HIU group (n = 11, 32.4%; p = 0.299). At follow-up, the SFR and IFR was 96% and 88% at 3-months, and 82% and 71% at 12-months, respectively (p method to OIU, and it has similar success rates in the treatment of short segment bulbar urethral strictures. PMID:29732217

  19. Targeting of liver tumour in rats by selective delivery of holmium-166 loaded microspheres: a biodistribution study

    Nijsen, F.; Rook, D.; Zonnenberg, B.; Klerk, J. de; Rijk, P. van; Schip, F. van het [Dept. of Nuclear Medicine, University Medical Center, Utrecht (Netherlands); Brandt, C. [Animal Inst., Utrecht Univ. (Netherlands); Meijer, R. [Dept. of Radiology, Univ. Medical Center, Utrecht (Netherlands); Dullens, H. [Dept. of Pathology, Univ. Medical Center, Utrecht (Netherlands); Hennink, W. [Dept. of Pharmaceutics, Utrecht Univ. (Netherlands)

    2001-06-01

    Intra-arterial administration of beta-emitting particles that become trapped in the vascular bed of a tumour and remain there while delivering high doses, represents a unique approach in the treatment of both primary and metastatic liver tumours. Studies on selective internal radiation therapy of colorectal liver metastases using yttrium-90 glass microspheres have shown encouraging results. This study describes the biodistribution of 40-{mu}m poly lactic acid microspheres loaded with radioactive holmium-166, after intra-arterial administration into the hepatic artery of rats with implanted liver tumours. Radioactivity measurements showed >95% retention of injected activity in the liver and its resident tumour. The average activity detected in other tissues was {<=}0.1%ID/g, with incidental exceptions in the lungs and stomach. Very little {sup 166}Ho activity was detected in kidneys (<0.1%ID/g), thereby indicating the stability of the microspheres in vivo. Tumour targeting was very effective, with a mean tumour to liver ratio of 6.1{+-}2.9 for rats with tumour (n=15) versus 0.7{+-}0.5 for control rats (n=6; P<0.001). These ratios were not significantly affected by the use of adrenaline. Histological analysis showed that five times as many large (>10) and medium-sized (4-9) clusters of microspheres were present within tumour and peritumoural tissue, compared with normal liver. Single microspheres were equally dispersed throughout the tumour, as well as normal liver parenchyma. (orig.)

  20. Kinetics of heterogeneous catalysis oxidation of carbon monoxide

    Khawaja, Y.; Sadiq, A.

    1987-10-01

    An irreversible kinetic surface-reaction model, based upon the reaction of carbon monoxide nd oxygen on a catalyst surface is investigated by means of Monte Carlo simulation. The adsorbed molecules/atoms on the surface undergo both first and second order kinetic phase transitions. The first order transition is found to occur at x/sub/co=x/sub/2=0.5255 with an error bar of 0.0003, where x/sub/co is the concentration of carbon monoxide in the gas phase. The time evolution of this catalytic reaction is studied both analytically and by computer simulation. Slightly above x/sub/2, the oxygen coverage relaxation time for the oxygen is found to diverage as the inverse of 3.54 times the absolute of the difference of x/sub/2 and x/sub/co. (orig./A.B.)

  1. Composite catalyst for carbon monoxide and hydrocarbon oxidation

    Liu, Wei; Flytzani-Stephanopoulos, Maria

    1996-01-01

    A method and composition for the complete oxidation of carbon monoxide and/or hydrocarbon compounds. The method involves reacting the carbon monoxide and/or hydrocarbons with an oxidizing agent in the presence of a metal oxide composite catalyst. The catalyst is prepared by combining fluorite-type oxygen ion conductors with active transition metals. The fluorite oxide, selected from the group consisting of cerium oxide, zirconium oxide, thorium oxide, hafnium oxide, and uranium oxide, and may be doped by alkaline earth and rare earth oxides. The transition metals, selected from the group consisting of molybdnum, copper, cobalt, maganese, nickel, and silver, are used as additives. The atomic ratio of transition metal to fluorite oxide is less than one.

  2. Digit and letter alexia in carbon monoxide poisoning

    Qingyu Shen; Xiaoming Rong; Rui Pan; Ying Peng; Wei Peng; Yamei Tang

    2012-01-01

    This study examined a 24-year-old patient with delayed encephalopathy, who was admitted to hospital with complaints of headache and visual impairment 1 week after acute carbon monoxide poisoning. The results of a visual field assessment, electroencephalography and head magnetic resonance imaging indicated damage to the cerebral cortex. After a 2-week treatment period, the patient had recovered from the visual impairment, but exhibited digit- and letter-reading difficulty. The Chinese aphasia battery and the number and letter battery supplement were conducted. The results revealed that the patient exhibited digit and letter alexia, while the ability to read Chinese characters was preserved. In contrast, the patient exhibited a deficit in Chinese character writing, while number and letter writing remained intact. Following treatment, reading and writing ability was improved and electroencephalographic abnormalities were ameliorated. Overall, our experimental findings demonstrated that delayed encephalopathy following acute carbon monoxide poisoning was characterized by digit and letter alexia.

  3. Interactions of carbon monoxide and hemoglobin at high altitude

    Collier, C.R. (Univ. of Southern California Medical Center, Los Angeles); Goldsmith, J.R.

    1983-01-01

    The health risks to U.S. populations who are exposed to ambient carbon monoxide and live at altitudes (such as Denver, Salt Lake City, and Albuquerque) were evaluated using a set of mathematical models. The assumption that a given increase in carboxyhemoglobin would require a more stringent volumetric air quality standard was tested. The results using the model predict that the 8-h or 1-h standards adopted for sea level condition need not be altered to protect individuals against health risks at altitude, if the standards are in volumetric terms. They would need to be reduced if the standards are left in gravimetric terms. If the guideline is to be based on a given decrement of oxygen tension, many other variables must be specified, but expected differences in ambient carbon monoxide have a small impact compared to the effect of altitude itself.

  4. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    Martijn eDiender; Alfons J.M. Stams; Alfons J.M. Stams; Diana Z. Sousa

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, ...

  5. Carbon Monoxide Poisoning: Death on Mount McKinley,

    1987-05-08

    Additionally, studies by Astrup(5) and Thomas(6) have reported decreased erythrocytic 2, 3- diphosphoglycerate (2, 3-DPG) concentrations with acute...Halebian, et al found no significant difference in measured 02 consumption or extraction between dogs subjected to CO poisoning vs nitrogen anoxia .(9...Astrup P: Intraerythrocytic 2,3- diphosphoglycerate and carbon monoxide exposure. Ann NY Acad Sci 1970;174:252-254. 6. Thomas MF, Penny DG: Hematologic

  6. Diffusion-weighted MR imaging findings in carbon monoxide poisoning

    Teksam, M.; Casey, S.O.; Michel, E.; Liu, H.; Truwit, C.L.

    2002-01-01

    Diffusion-weighted MR imaging (DWI) of two patients with carbon monoxide (CO) poisoning demonstrated white matter and cortical hyperintensities. In one patient, the changes on the FLAIR sequence were more subtle than those on DWI. The DWI abnormality in this patient represented true restriction. In the second patient, repeated exposure to CO caused restricted diffusion. DWI may be helpful for earlier identification of the changes of acute CO poisoning. (orig.)

  7. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Kaminaga, Kenichi; Sei, Ryosuke; Hayashi, Kouichi; Happo, Naohisa; Tajiri, Hiroo; Oka, Daichi; Fukumura, Tomoteru; Hasegawa, Tetsuya

    Rare earth sesquioxides like Y2O3 are known as widegap insulators with the highly stable closed shell trivalent rare earth ions. On the other hand, rare earth monoxides such as YO have been recognized as gaseous phase, and only EuO and YbO were thermodynamically stable solid-phase rock salt monoxides. In this study, solid-phase rock salt yttrium monoxide, YO, was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO possesses unusual valence of Y2+ ([Kr] 4d1) . In contrast with Y2O3, YO was narrow gap semiconductor with dark-brown color. The electrical conductivity was tunable from 10-1 to 103 Ω-1 cm-1 by introducing oxygen vacancies as electron donor. Weak antilocalization behavior was observed indicating significant spin-orbit coupling owing to 4 d electron carrier. The absorption spectral shape implies the Mott-Hubbard insulator character of YO. Rare earth monoixdes will be new platform of functional oxides. This work was supported by JST-CREST, the Japan Society for the Promotion of Science (JSPS) with Grant-in-Aid for Scientific Research on Innovative Areas (Nos. 26105002 and 26105006), and Nanotechnology Platform (Project No.12024046) of MEXT, Japan.

  8. Carbon monoxide and carbon dioxide interaction with tantalum

    Belov, V.D.; Ustinov, Yu.K.; Komar, A.P.

    1978-01-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (α and β' 1 ) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the β' 1 state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10 12 sec -1 , and γ = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively. (Auth.)

  9. Carbon monoxide and carbon dioxide interaction with tantalum

    Belov, V D; USTINOV, YU K; KOMAR, A P [AN SSSR, LENINGRAD. FIZIKO-TEKHNICHESKIJ INST.

    1978-03-01

    The adsorption of carbon monoxide and carbon dioxide on tantalum and the dissolution of these gases in the adsorbent at T >= 300 K have been studied. The flash-filament method (FFM) in a monopole mass-spectrometer and a field emission microscopy was used in the same apparatus. Carbon monoxide and carbon dioxide dissociate on the tantalum surface, carbon monoxide being desorbed in both cases during the flash. The desorption curves of CO reveal three different binding states: two of them (..cap alpha.. and ..beta..'/sub 1/) for the adsorbed particles whereas the high temperature desorption state relates to the adsorbate dissolved in the metal. For the ..beta..'/sub 1/ state of CO the activation energy, the pre-exponential factor and the kinetic order in the kinetic equation of desorption have been estimated. They turned out to be E = 110 kcal/mol, C = 3 X 10/sup 12/ sec/sup -1/, and ..gamma.. = 1. The activation energy of diffusion for CO in tantalum and the energy of outgassing for the metal were found to be 9.4 and 49 kcal/mole, respectively.

  10. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  11. Combined retrograde flexible ureteroscopic lithotripsy with holmium YAG laser for renal calculi associated with ipsilateral ureteral stones.

    Cocuzza, Marcello; Colombo, Jose R; Ganpule, Arvind; Turna, Burak; Cocuzza, Antonio; Dhawan, Divyar; Santos, Bruno; Mazzucchi, Eduardo; Srougi, Miguel; Desai, Mahesh; Desai, Mihir

    2009-02-01

    The purpose of this study was to evaluate the effectiveness of combined ureteroscopic holmium YAG lithotripsy for renal calculi associated with ipsilateral ureteral stones. Between August 2002 and March 2007, retrograde flexible ureteroscopic stone treatment was attempted in 351 cases. Indication for treatment was concurrent symptomatic ureteral stones in 63 patients (group I). Additional operative time and perioperative complication rates were compared to a group of 39 patients submitted to ureteroscopic treatment for ureteral calculi exclusively (group II). Mean ureteral stone size was 8.0 +/- 2.6 mm and 8.1 +/- 3.4 mm for groups I and II, respectively. Mean operative time for group I was 67.9 +/- 29.5 minutes and for group 2 was 49.3 +/- 13.2 minutes (p stone size was 10.7 +/- 6.4 mm, overall stone free rate in group I was 81%. However, considering only patients with renal stones smaller than 15 mm, the stone free rate was 88%. Successful treatment occurred in 81% of patients presenting lower pole stones, but only 76% of patients with multiple renal stones became stone free. As expected, stone free rate showed a significant negative correlation with renal stone size (p = 0.03; r = -0.36). Logistic regression model indicated an independent association of renal stones smaller than 15 mm and stone free rate (OR = 13.5; p = 0.01). Combined ureteroscopic treatment for ureteral and ipsilateral renal calculi is a safe and attractive option for patients presenting for symptomatic ureteral stone and ipsilateral renal calculi smaller than 15 mm.

  12. Initial Clinical Experience with a Modulated Holmium Laser Pulse—Moses Technology: Does It Enhance Laser Lithotripsy Efficacy?

    Michael Mullerad

    2017-10-01

    Full Text Available Objective The Lumenis® High-power Holmium Laser (120H has a unique modulated pulse mode, Moses™ technology. Moses technology modulates the laser pulse to separate the water (vapor bubble, then deliver the remaining energy through the bubble. Proprietary laser fibers were designed for the Moses technology. Our aim was to compare stone lithotripsy with and without the Moses technology. Methods We designed a questionnaire for the urologist to fill immediately after each ureteroscopy in which the Lumenis 120H was used. We compared procedures with (n=23 and without (n=11 the use of Moses technology. Surgeons ranked the Moses technology in 23 procedures, in comparison to regular lithotripsy (worse, equivalent, better, much better. Laser working time and energy use were collected from the Lumenis 120H log. Results During 4 months, five urologists used the Lumenis 120H in 34 ureteroscopy procedures (19 kidney stones, 15 ureteral stones; 22 procedures with a flexible ureteroscope, and 12 with a semi-rigid ureteroscope. Three urologists ranked Moses technology as much better or better in 17 procedures. In 2 cases, it was ranked equivalent, and in 4 cases ranking was not done. Overall, laser lithotripsy with Moses technology utilized laser energy in less time to achieve a satisfying stone fragmentation rate of 95.8 mm3/min versus 58.1 mm3/min, P=0.19. However, this did not reach statistical significance. Conclusion The new Moses laser technology demonstrated good stone fragmentation capabilities when used in everyday clinical practice.

  13. Comparison of Surgical Outcomes Between Holmium Laser Enucleation and Transurethral Resection of the Prostate in Patients With Detrusor Underactivity

    Myeong Jin Woo

    2017-03-01

    Full Text Available Purpose Currently, holmium laser enucleation of the prostate (HoLEP and transurethral resection of the prostate (TURP are the standard surgical procedures used to treat benign prostatic hyperplasia (BPH. Several recent studies have demonstrated that the surgical management of BPH in patients with detrusor underactivity (DU can effectively improve voiding symptoms, but comparative data on the efficacy of HoLEP and TURP are insufficient. Therefore, we compared the short-term surgical outcomes of HoLEP and TURP in patients with DU. Methods From January 2010 to May 2015, 352 patients underwent HoLEP or TURP in procedures performed by a single surgeon. Of these patients, 56 patients with both BPH and DU were enrolled in this study (HoLEP, n=24; TURP, n=32. Surgical outcomes were retrospectively compared between the 2 groups. DU was defined as a detrusor pressure at maximal flow rate of <40 cm H2O as measured by a pressure flow study. Results The preoperative characteristics of patients and the presence of comorbidities were comparable between the 2 groups. The TURP group showed a significantly shorter operative time than the HoLEP group (P=0.033. The weight of the resected prostate was greater in the HoLEP group, and postoperative voiding parameters, including peak flow rate and postvoid residual urine volume were significantly better in the HoLEP group than in the TURP group. Conclusions HoLEP can be effectively and safely performed in patients with DU and can be expected to have better surgical outcomes than TURP in terms of the improvement in lower urinary tract symptoms.

  14. Serial Changes in Sexual Function Following Holmium Laser Enucleation of the Prostate: A Short-term Follow-up Study.

    Jeong, Min Su; Ha, Seung Beom; Lee, Chang Ju; Cho, Min Chul; Kim, Soo Woong; Paick, Jae-Seung

    2012-02-01

    To evaluate the serial changes in sexual function in the short-term period after holmium laser enucleation of the prostate (HoLEP) for benign prostatic hyperplasia (BPH) and to investigate whether a change in each domain of the International Index of Erectile Function (IIEF) is associated with improvement of micturition. Thirty-eight potent men who underwent HoLEP and in whom complete 12-month follow-up data on the IIEF were available were included in this retrospective study. All patients underwent a baseline evaluation for BPH. The surgical outcome was evaluated at 1, 3, 6, and 12 months postoperatively by use of the International Prostate Symptom Score, IIEF, and uroflowmetry. The mean age and body mass index of the patients was 64.5±6.2 years and 24.2±2.6 kg/m(2), respectively. Mean total prostate volume and transitional zone volume were 48.8±18.8 ml and 24.2±16.1 ml, respectively. Most IIEF domain scores showed a slight decrease at 1, 3, and 6 months after surgery but recovered to the baseline or showed a marginal but nonsignificant increase at 12 months postoperatively compared with baseline. Orgasmic function and the overall sexual satisfaction domain score remained slightly reduced up to 12 months postoperatively. There was no significant correlation between improvement of micturition and change in sexual function throughout the follow-up period after surgery. Although HoLEP achieves significant improvements in micturition, overall sexual function decreases slightly in the early postoperative period, but recovers to the baseline at 12 months postoperatively. Our data suggest that changes in sexual function after HoLEP are not associated with improvement of micturition.

  15. Expanding rare-earth oxidation state chemistry to molecular complexes of holmium(II) and erbium(II).

    MacDonald, Matthew R; Bates, Jefferson E; Fieser, Megan E; Ziller, Joseph W; Furche, Filipp; Evans, William J

    2012-05-23

    The first molecular complexes of holmium and erbium in the +2 oxidation state have been generated by reducing Cp'(3)Ln [Cp' = C(5)H(4)SiMe(3); Ln = Ho (1), Er (2)] with KC(8) in the presence of 18-crown-6 in Et(2)O at -35 °C under argon. Purification and crystallization below -35 °C gave isomorphous [(18-crown-6)K][Cp'(3)Ln] [Ln = Ho (3), Er (4)]. The three Cp' ring centroids define a trigonal-planar geometry around each metal ion that is not perturbed by the location of the potassium crown cation near one ring with K-C(Cp') distances of 3.053(8)-3.078(2) Å. The metrical parameters of the three rings are indistinguishable within the error limits. In contrast to Ln(2+) complexes of Eu, Yb, Sm, Tm, Dy, and Nd, 3 and 4 have average Ln-(Cp' ring centroid) distances only 0.029 and 0.021 Å longer than those of the Ln(3+) analogues 1 and 2, a result similar to that previously reported for the 4d(1) Y(2+) complex [(18-crown-6)K][Cp'(3)Y] (5) and the 5d(1) La(2+) complex [K(18-crown-6)(Et(2)O)][Cp″(3)La] [Cp″ = 1,3-(Me(3)Si)(2)C(5)H(3)]. Surprisingly, the UV-vis spectra of 3 and 4 are also very similar to that of 5 with two broad absorptions in the visible region, suggesting that 3-5 have similar electron configurations. Density functional theory calculations on the Ho(2+) and Er(2+) species yielded HOMOs that are largely 5d(z(2)) in character and supportive of 4f(10)5d(1) and 4f(11)5d(1) ground-state configurations, respectively.

  16. Enucleation ratio efficacy might be a better predictor to assess learning curve of holmium laser enucleation of the prostate

    Chang Wook Jeong

    2012-06-01

    Full Text Available PURPOSE: To appraise the evaluation methods for learning curve and to analyze the non-mentor-aided learning curve and early complications following the holmium laser enucleation of the prostate. MATERIALS AND METHODS:One-hundred and forty (n=140 consecutive patients who underwent HoLEP from July 2008 to July 2010 by a single surgeon (SJO were enrolled. Perioperative clinical variables, including enucleation time, morcellation time, enucleation ratio (enucleation weight/transitional zone volume, enucleation efficacy (enucleated weight/enucleation time, enucleation ratio efficacy (enucleation ratio/enucleation time, and early complication rate were analyzed. RESULTS: Mean prostate volume was 62.7 mL (range 21-162 and preoperative International Prostate Symptom Score (IPSS was 19.0 (4-35. Mean enucleation time and morcellation time were 49.9±23.8 (S.D. min and 11.0±9.7 min, respectively. Median duration of postoperative indwelling catheter was 1 (1-7 day and median hospital stay was 1 (1-6 day. There were a total of 31 surgery-related complications in 27 patients (19.3%, and all were manageable. There was an increasing trend of enucleation efficacy in the first 50 cases. However, enucleation efficacy was linearly correlated with the prostate size (correlation coefficients, R=0.701, p<0.001. But, enucleation ratio efficacy could eliminate the confounding effect of the prostate size (R=-0.101, p=0.233. The plateau of enucleation ratio efficacy was reached around the twenty-fifth case. CONCLUSIONS: Our results demonstrated that the operative learning curve plateau is reached after about 25 cases. We propose that a more appropriate parameter for estimating the operative learning curve is enucleation ratio efficacy, rather than enucleation efficacy.

  17. Activity coefficients in (hydrogen chloride+holmium chloride) (aq) from T=(278.15 to 328.15) K

    Roy, Rabindra N.; Roy, Lakshmi N.; Tabor, Bennett J.; Richards, Sarah J.; Cummins, Mason P.; Himes, Curtis A.; Gibbs, Stephanie N.; Christiansen, Edward B.

    2005-01-01

    Activity coefficients of HCl in (hydrogen chloride+holmium chloride) (aq) have been calculated from the observed e.m.f.s using the Nernst equation. The temperatures ranged from (278.15 to 328.15) K at 5 K intervals and at constant total ionic strengths of (0.01, 0.025, 0.05, 0.1, 0.25, 0.5, 1.0, and 1.5) mol.kg -1 . Electromotive-force measurements were made on the cell without liquid junction of the type:Pt vertical bar H 2 (g,p=101.325kPa) vertical bar HCl(m A ),HoCl 3 (m B ) vertical bar AgCl(s), vertical bar Ag(s) The results of the activity coefficients of HCl for this mixed electrolyte mixture have been interpreted in terms of the simpler Harned's equations and the ion-interaction model of Pitzer. Results show that the quadratic term is sufficient for the full range of Y B (the ionic strength fraction of the salt) to 0.9 at all the ionic strengths studied. The Pitzer's mixing parameters S θH,Ho and Ψ H,Ho,Cl (including higher order electrostatic effects) and θ H,Ho and Ψ H,Ho,Cl (excluding higher order electrostatic effects) have been determined. These values at T=298.15 K are: S θH , Ho =0.115, Ψ H,Ho,Cl =-.071; and θ H,Ho =-.663, Ψ H,Ho,Cl =0.165. The parameters obtained in this study reproduce the activity coefficients of HCl in the mixtures within 0.015 over the entire range of ionic strengths and within 0.009 for I>=0.05 mol.kg -1 over the entire temperature range

  18. Pulsed liquid jet dissector using holmium: YAG laser - a novel neurosurgical device for brain incision without imparing vessels

    Hirano, T.; Nakagawa, A.; Jokura, H.; Shirane, R.; Uenohara, H.; Ohyama, H.; Takayama, K.

    2003-01-01

    Neurosurgery has long required a method for dissecting brain tissue without damaging principal vessels and adjacent tissue, so as to prevent neurological complications after operation. In this study we constructed a prototype of such a device and used it in an attempt to resect beagle brain cortex. The prototype device consisted of an optical fiber, a Y adapter, and a nozzle whose internal exit diameter was 100 μm. Cold physiological saline (4 o C) was supplied to it at a rate of 40 ml/h. Pulsed liquid jets were ejected from the nozzle by a pulsed Holmium:YAG) (Ho:YAG) laser at an irradiation energy of 300 mJ/pulse. The profile of the liquid jet was observed with a high-speed camera while changing the distance between the optical fiber end and nozzle exit (equivalent to the Standoff distance). With this device (3 Hz operation), brain dissection of anesthetized beagles was attempted while measuring the local temperature of the target. A histological study of the incised parts was also performed. When the Standoff distance was 24 mm, the liquid jet was emitted straight from the nozzle at a maximum initial velocity of 50 m/s. The brain parenchyma was cut with this device while preserving vessels larger than 200 μm in diameter and keeping the operative field clear. The local temperature rose to no more than 41 o C, below the functional heat damage threshold of brain tissue. Histological findings showed no signs of thermal tissue damage around the dissected margin. The Ho:YAG laser-induced liquid jet dissector can be applied to neurosurgery after incorporating some minor improvements. (author)

  19. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    Metin Uysalol; Ezgi Paslı Uysalol; Gamze Varol Saraçoğlu; Semra Kayaoğlu

    2011-01-01

    Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female) who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide into...

  20. Carbon monoxide poisoning - Immediate diagnosis and treatment are crucial to avoid complications.

    Rosenthal, L.D. [Case Western Reserve University, Cleveland, OH (United States)

    2006-03-15

    Carbon monoxide is an odorless, colorless, tasteless gas produced by the incomplete combustion of carbon-containing fuels (oil, kerosene, coal, wood) or the inadequate ventilation of natural gas. When carbon monoxide is introduced into the bloodstream, it binds to hemoglobin, reducing the number of binding sites available for oxygen. Carbon monoxide also changes the structure of the hemoglobin molecule, which makes it even more difficult for oxygen that has attached to be released into tissues. The resulting tissue ischemia can lead to organ failure, permanent changes in cognition, or death. Carbon monoxide poisoning is the leading cause of death by poisoning in industrialized countries.

  1. XPS study on the surface reaction of uranium metal with carbon monoxide at 200 degree C

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-12-01

    The surface reaction of uranium metal with carbon monoxide at 200 degree C has been studied by X-ray photoelectron spectroscopy (XPS). The carbon monoxide adsorption on the surface oxide layer resulted in U4f peak shifting to the lower binding energy and the content of oxygen in the oxide is decreased. O/U radio decreases with increasing the exposure of carbon monoxide to the surface layer. The investigation indicated the surface layer of uranium metal was further reduced in the atmosphere of carbon monoxide at high temperature. (3 refs., 5 figs.)

  2. Study on the surface oxidation resistance of uranium metal in the atmosphere of carbon monoxide

    Wang Xiaolin; Fu Yibei; Xie Renshou

    1999-01-01

    The surface reactions of different layers on uranium metal with carbon monoxide at 25, 80 and 200 degree C are studied by X-ray photoelectron spectroscopy (XPS). The experimental results show that the carbon monoxide is adsorbed on the surface oxide layer of uranium and interacted each other. The content of oxygen in the surface oxide and O/U ratio are decreased with increasing the exposure of carbon monoxide to the surface layer. The effect of reduction on the metal surface is more obviously with a higher temperature and increasing of layer thickness. The investigation indicates the uranium metal has resistance to further oxidation in the atmosphere of carbon monoxide

  3. Mixing ratios of carbon monoxide in the troposphere

    Novelli, P.C.; Steele, L.P. (Univ. of Colorado, Boulder (United States)); Tans, P.P. (NOAA, Boulder, CO (United States))

    1992-12-20

    Carbon monoxide (CO) mixing ratios were measured in air samples collected weekly at eight locations. The air was collected as part of the CMDL/NOAA cooperative flask sampling program (Climate Monitoring and Diagnostics Laboratory, formerly Geophysical Monitoring for Climatic Change, Air Resources Laboratory/National Oceanic and Atmospheric Administration) at Point Barrow, Alaska, Niwot Ridge, Colorado, Mauna Loa and Cape Kumakahi, Hawaii, Guam, Marianas Islands, Christmas Island, Ascension Island and American Samoa. Half-liter or 3-L glass flasks fitted with glass piston stopcocks holding teflon O rings were used for sample collection. CO levels were determined within several weeks of collection using gas chromatography followed by mercuric oxide reduction detection, and mixing ratios were referenced against the CMDL/NOAA carbon monoxide standard scale. During the period of study (mid-1988 through December 1990) CO levels were greatest in the high latitudes of the northern hemisphere (mean mixing ratio from January 1989 to December 1990 at Point Barrow was approximately 154 ppb) and decreased towards the south (mean mixing ratio at Samoa over a similar period was 65 ppb). Mixing ratios varied seasonally, the amplitude of the seasonal cycle was greatest in the north and decreased to the south. Carbon monoxide levels were affected by both local and regional scale processes. The difference in CO levels between northern and southern latitudes also varied seasonally. The greatest difference in CO mixing ratios between Barrow and Samoa was observed during the northern winter (about 150 ppb). The smallest difference, 40 ppb, occurred during the austral winter. The annually averaged CO difference between 71[degrees]N and 14[degrees]S was approximately 90 ppb in both 1989 and 1990; the annually averaged interhemispheric gradient from 71[degrees]N to 41[degrees]S is estimated as approximately 95 ppb. 66 refs., 5 figs., 5 tabs.

  4. Pathology of carbon monoxide poisoning in two cats.

    Sobhakumari, Arya; Poppenga, Robert H; Pesavento, J Brad; Uzal, Francisco A

    2018-03-05

    Carbon monoxide (CO), a common cause of poisoning in human beings has also been implicated in the death of animals. Though there are multiple studies on CO poisoning and relevant lethal blood COHb concentrations in humans, there are no reliable reports of diagnostic lethal carboxyhemoglobin percentage of saturation (COHb%) in cats. Additionally, due to shared housing environments, exposures to companion animals can be a surrogate for lethal exposures in human beings and provide valuable information in concurrent forensic investigations. Two adult Singapura brown ticked cats were submitted to the California Animal Health and Food Safety Laboratory (CAHFS) for necropsy and diagnostic work-up. These animals were found dead along with their two deceased owners. Similar lesions were observed in both cats. At necropsy, gross lesions consisted of multifocal, large, irregular, bright red spots on the skin of the abdomen and the inner surface of ear pinnae, bright red muscles and blood. The carcasses, and tissues fixed in formalin retained the bright red discoloration for up to two weeks. Microscopic lesions included diffuse pulmonary congestion and edema, and multifocal intense basophilia of cardiomyocytes mostly affecting whole fibers or occasionally a portion of the fiber. Based on the clinical history,gross and microscopic changes, cyanide or carbon monoxide poisoning was suspected. Blood samples analyzed for carbon monoxide showed 57 and 41% carboxyhemoglobin COHb%. Muscle samples were negative for cyanide. There are no established reference values for lethal COHb concentration in cats. The COHb % values detected in this case which fell within the lethal range reported for other species, along with the gross lesions and unique histological findings in the heart suggest a helpful criteria for diagnosis of CO intoxication associated death in cats. This case demonstrates that since pets share the same environment as human beings and often are a part of their activities

  5. Iodine monoxide in the north subtropical free troposphere [Discussion paper

    Puentedura, Olga; Gil-Ojeda, Manuel; Saiz-Lopez, Alfonso; Hay, Tim; Navarro Comas, Mónica; Gómez Peláez, Ángel Jesús; Cuevas Agulló, Emilio; Iglesias, J.

    2011-01-01

    Iodine monoxide (IO) was retrieved using a new multi-axis DOAS instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and is hence representative of the free troposphere. We report daily observations from May to August 2010 at different viewing angles. During this period, t...

  6. Iodine monoxide in the north subtropical free troposphere

    O. Puentedura; M. Gil; A. Saiz-Lopez; T. Hay; M. Navarro-Comas; A. Gómez-Pelaez; E. Cuevas; J. Iglesias; L. Gomez

    2012-01-01

    Iodine monoxide (IO) differential slant column densities (DSCD) have been retrieved from a new multi-axis differential optical absorption spectroscopy (MAX-DOAS) instrument deployed at the Izaña subtropical observatory as part of the Network for the Detection of Atmospheric Composition Change (NDACC) programme. The station is located at 2370 m a.s.l., well above the trade wind inversion that limits the top of the marine boundary layer, and hence is representative of the free troposphere. We r...

  7. Thermal Degradation of Lead Monoxide Filled Polymer Composite Radiation Shields

    Harish, V.; Nagaiah, N.

    2011-01-01

    Lead monoxide filled Isophthalate resin particulate polymer composites were prepared with different filler concentrations and investigated for physical, thermal, mechanical and gamma radiation shielding characteristics. This paper discusses about the thermo gravimetric analysis of the composites done to understand their thermal properties especially the effect of filler concentration on the thermal stability and degradation rate of composites. Pristine polymer exhibits single stage degradation whereas filled composites exhibit two stage degradation processes. Further, the IDT values as well as degradation rates decrease with the increased filler content in the composite.

  8. Chlorination of niobium oxide in the presence of carbon monoxide

    Freitas, L.R. de

    1984-01-01

    The chlorination kinetics of niobium pentoxide in the presence of carbon monoxide between 500-800 0 C of temperature is studied. The following variable that influences on the reaction rate are analysed: gas flow, geometry and volume of the Nb 2 O 5 samples, reaction temperature and composition of the chlorinated mixture. At the same time, two other materials were studied: the CaO.Nb 2 O 5 (synthetized in laboratory) and pyrochlorine concentrates. The three materials are compared for the chlorination method used. (M.A.C.) [pt

  9. Thermodynamic properties of liquid mixtures of carbon monoxide and methane

    Calado, J.C.G.; Guedes, H.J.R.; Nunes da Ponte, M.; Streett, W.B.

    1984-04-01

    Researchers conducted pressure-volume-temperature measurements of liquid methane at -230/sup 0/F and of six liquid mixtures of carbon monoxide and methane at -250/sup 0/, -240/sup 0/, and -230/sup 0/F from just above the saturation vapor pressure to the freezing pressure of methane. The excess volume proved to be large and negative at low pressures but less negative as the pressure increased, being almost zero at the highest pressure. Of the thermodynamic functions, excess enthalpy and excess entropy were much more sensitive to pressure than excess Gibbs energy. Conformal solution theory in the van der Waals one-fluid form reproduced the experimental results very successfully.

  10. Pathways and bioenergetics of anaerobic carbon monoxide fermentation.

    Martijn eDiender

    2015-11-01

    Full Text Available Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  11. Pathways and Bioenergetics of Anaerobic Carbon Monoxide Fermentation.

    Diender, Martijn; Stams, Alfons J M; Sousa, Diana Z

    2015-01-01

    Carbon monoxide can act as a substrate for different modes of fermentative anaerobic metabolism. The trait of utilizing CO is spread among a diverse group of microorganisms, including members of bacteria as well as archaea. Over the last decade this metabolism has gained interest due to the potential of converting CO-rich gas, such as synthesis gas, into bio-based products. Three main types of fermentative CO metabolism can be distinguished: hydrogenogenesis, methanogenesis, and acetogenesis, generating hydrogen, methane and acetate, respectively. Here, we review the current knowledge on these three variants of microbial CO metabolism with an emphasis on the potential enzymatic routes and bio-energetics involved.

  12. Low-power holmium:YAG laser urethrotomy for treatment of urethral strictures: functional outcome and quality of life.

    Kamp, Stefan; Knoll, Thomas; Osman, Mahmoud M; Köhrmann, Kai Uwe; Michel, Maurice S; Alken, Peter

    2006-01-01

    To evaluate the efficacy of endourethrotomy with the holmium:YAG laser as a minimally invasive treatment for urethral stricture. Between January 2002 and January 2004, 32 male patients with symptomatic urethral strictures (8 bulbar, 9 penile, 9 combined) were treated with Ho:YAG-laser urethrotomy in our department. The stricture was iatrogenic in 60% (N = 18), inflammatory in 16.6% (N = 5), traumatic in 13.3% (N = 4), and idiopathic in 7% (N = 3). The stricture was incised under vision at the 12 o'clock location or the site of maximum scar tissue or narrowing in asymmetric strictures. Laser energy was set on 1200 to 1400 mJ with a frequency of 10 to 13 Hz. Postoperatively, drainage of the bladder was performed for 4 days using a 18F silicone catheter. Triamcinolone was instilled intraurethrally after removal of the catheter in all patients. Patients were followed up by mailed questionnaire, including International Prostate Symptom Score and quality of life. Retrograde endoscopic Ho:YAG laser urethrotomy could be performed in all 32 patients. Most patients (22; 68.7%) did not need any reintervention. Ten patients developed recurrent strictures that were treated by another laser urethrotomy in 4 patients (12.5%), while 6 patients (18.7%) needed open urethroplasty with buccal mucosa. Including 2 patients treated with repeat laser urethrotomy, 24 patients (75%) were considered successful after a mean follow-up of 27 months (range 13-38 months). No intraoperative complications were encountered, although in 5% of patients, a urinary-tract infection was diagnosed postoperatively. No gross hematuria occurred. The Ho:YAG laser urethrotomy is a safe and effective minimally invasive therapeutic modality for urethral stricture with results comparable to those of conventional urethrotomy. Further data from long-time follow-up are necessary to compare the success rate with that of conventional urethrotomy and urethroplasty. Nevertheless, the Ho:YAG laser urethrotomy might at

  13. Efficacy of holmium. Yttrium-aluminium-garnet (Ho: YAG) laser therapy for arthroscopic synovectomy of rheumatoid arthritis

    Inoue, Yasuo; Inoue, Kazuhiko; Kanbe, Katsuaki

    2008-01-01

    To clarify the efficacy of holmium: yttrium-aluminium-garnet (Ho: YAG) laser therapy for arthroscopic synovectomy of rheumatoid arthritis (RA), we treated 13 shoulders of 11 RA patients of whom 1 was stage I, 7 stage II, 2 stage III, and 1 stage IV. The duration of RA is 4.6 years on average and the follow-up period is an average of 14 months. The Ho: YAG laser was set at 10 Watt (W) to treat the bone erosion areas so as to reach the deep zones of the pannus in order to resect the synovium. We compared C-reactive protein (CRP), Disease activity score (DAS) 28 and magnetic resonance image (MRI) findings before and after surgery. We cultured primary synovial cells to assay cytokine production of interleukin (IL)-1β, IL-6 and tumor necrosis factor (TNF)-α. Morphological examination was performed after treatment with the Ho: YAG laser at 0, 1, 5, 10, 15 and 20 W. We found villous synovium proliferation with vascularity in the rotator interval and supra spinatus tendon in the shoulder joints. In the subacromial bursa, yellow fat tissue and white fibrous soft tissue were detected in almost all shoulders. After synovectomy using the Ho: YAG laser, CRP decreased from an average of 3.6 to 0.8 and DAS28 also decreased from an average of 5.4 to 3.7 at 14 months after surgery. MRI showed decreased panni with synovium and did not precede joint destruction after 14 months in 10 shoulders out of 13 (77%). At 20 W of the Ho: YAG laser treatment, the synovial cells shrank as in apoptosis and the number of cells also decreased. Laser treatment also resulted in the following significant changes: TNF-α production increased at 1, 10, 15 and 20 W (compared with 0 W) but not dose dependently; IL-1β and IL-6 increased up to 10 W (compared with 0 W) but decreased at 15 and 20 W (compared with 10 W). In morphological examination, after treatment with the Ho: YAG laser at 15 W, the synovial cells expanded and the number of cells decreased. Therefore, Ho: YAG laser therapy is effective

  14. Activity coefficients in (hydrogen chloride+holmium chloride) (aq) from T=(278.15 to 328.15) K

    Roy, Rabindra N. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States)]. E-mail: rroy@drury.edu; Roy, Lakshmi N. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Tabor, Bennett J. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Richards, Sarah J. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Cummins, Mason P. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Himes, Curtis A. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Gibbs, Stephanie N. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States); Christiansen, Edward B. [Hoffman Department of Chemistry, Drury University, Springfield, MO 65802 (United States)

    2005-07-15

    Activity coefficients of HCl in (hydrogen chloride+holmium chloride) (aq) have been calculated from the observed e.m.f.s using the Nernst equation. The temperatures ranged from (278.15 to 328.15) K at 5 K intervals and at constant total ionic strengths of (0.01, 0.025, 0.05, 0.1, 0.25, 0.5, 1.0, and 1.5) mol.kg{sup -1}. Electromotive-force measurements were made on the cell without liquid junction of the type:Pt vertical bar H{sub 2}(g,p=101.325kPa) vertical bar HCl(m{sub A}),HoCl{sub 3}(m{sub B}) vertical bar AgCl(s), vertical bar Ag(s) The results of the activity coefficients of HCl for this mixed electrolyte mixture have been interpreted in terms of the simpler Harned's equations and the ion-interaction model of Pitzer. Results show that the quadratic term is sufficient for the full range of Y{sub B} (the ionic strength fraction of the salt) to 0.9 at all the ionic strengths studied. The Pitzer's mixing parameters S{sub {theta}}{sub H,Ho} and {psi}{sub H,Ho,Cl} (including higher order electrostatic effects) and {theta}{sub H,Ho} and {psi}{sub H,Ho,Cl} (excluding higher order electrostatic effects) have been determined. These values at T=298.15 K are: S{sub {theta}}{sub H},{sub Ho}=0.115, {psi}{sub H,Ho,Cl}=-.071; and {theta}{sub H,Ho}=-.663, {psi}{sub H,Ho,Cl}=0.165. The parameters obtained in this study reproduce the activity coefficients of HCl in the mixtures within 0.015 over the entire range of ionic strengths and within 0.009 for I>=0.05 mol.kg{sup -1} over the entire temperature range.

  15. The Future of Carbon Monoxide Measurements from Space

    Drummond, J.

    It is now over 20 years since the Measurements of Air Pollution from Space MAPS instrument made the first measurements of tropospheric carbon monoxide from the shuttle Since that time a number of instruments have flown including the Measurements Of Pollution In The Troposphere MOPITT Tropospheric Emission Spectrometer TES and SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY SCIAMCHY to name only three of many Each of these instruments has a unique observing method and unique mission characteristics It is accepted that measurements of carbon monoxide provide a useful proxy of the pollution of the troposphere and contribute significantly to studies of various phenomena in the atmosphere and atmosphere-surface interactions These measurements should therefore be continued -- but in what form Technology has progresses significantly since the current generation of instruments was designed and our ability to interpret the data from such instrumentation has likewise expanded It is therefore fruitful to consider what is the best set of measurements that can be made which parameters should be emphasized and which compromised on the way to the next generation of sensors The Measurements of Air Pollution Levels in the Environment MAPLE instrument is a study financed by the Canadian Space Agency to design a next-generation instrument and since instrument spacecraft and mission are now intimately linked a consideration of the whole mission is appropriate This talk will outline some potential developments in the hardware

  16. A carbon monoxide passive sampler: Research and development needs

    Traynor, G.W.; Apte, M.G.; Diamond, R.C.; Woods, A.L.

    1991-11-01

    In rare instances, carbon monoxide (CO) levels in houses can reach dangerously high concentrations, causing adverse health effects ranging from mild headaches to, under extreme conditions, death. Hundreds of fatal accidental carbon monoxide poisonings occur each year primarily due to the indoor operation of motor vehicles, the indoor use of charcoal for cooking, the operation of malfunctioning vented and unvented combustion appliances, and the misuse combustion appliances. Because there is a lack of simple, inexpensive, and accurate field sampling instrumentation, it is difficult for gas utilities and researchers to conduct field research studies designed to quantify the concentrations of CO in residences. Determining the concentration of CO in residences is the first step towards identifying the high risk appliances and high-CO environments which pose health risks. Thus, there exists an urgent need to develop and field-validate a CO-quantifying technique suitable for affordable field research. A CO passive sampler, if developed, could fulfill these requirements. Existing CO monitoring techniques are discussed as well as three potential CO-detection methods for use in a CO passive sampler. Laboratory and field research needed for the development and validation of an effective and cost-efficient CO passive sampler are also discussed.

  17. The electric dipole moment of cobalt monoxide, CoO.

    Zhuang, Xiujuan; Steimle, Timothy C

    2014-03-28

    A number of low-rotational lines of the E(4)Δ7/2 ← X(4)Δ7/2 (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h7/2, and the electron quadrupole parameter, eQq0, for the E(4)Δ7/2(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ(→)(el), for the X(4)Δ7/2 (υ = 0) and E(4)Δ7/2 (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F' = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F' = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  18. The electric dipole moment of cobalt monoxide, CoO

    Zhuang, Xiujuan, E-mail: zhuangxj@hnu.edu.cn [College of Physics and Microelectronics Science, Key Laboratory for Micro-Nano Physics and Technology of Hunan Province, Hunan University, Changsha 410082 (China); Steimle, Timothy C. [Department of Chemistry and Biochemistry, Arizona State University, Tempe, Arizona 85287-1604 (United States)

    2014-03-28

    A number of low-rotational lines of the E{sup 4}Δ{sub 7/2} ← X{sup 4}Δ{sub 7/2} (1,0) band system of cobalt monoxide, CoO, were recorded field free and in the presence of a static electric field. The magnetic hyperfine parameter, h{sub 7/2}, and the electron quadrupole parameter, eQq{sub 0}, for the E{sup 4}Δ{sub 7/2}(υ = 1) state were optimized from the analysis of the field-free spectrum. The permanent electric dipole moment, μ{sup -vector}{sub el}, for the X{sup 4}Δ{sub 7/2} (υ = 0) and E{sup 4}Δ{sub 7/2} (υ = 1) states were determined to be 4.18 ± 0.05 D and 3.28 ± 0.05 D, respectively, from the analysis of the observed Stark spectra of F′ = 7 ← F″ = 6 branch feature in the Q(7/2) line and the F′ = 8 ← F″ = 7 branch feature in the R(7/2) line. The measured dipole moments of CoO are compared to those from theoretical predictions and the trend across the 3d-metal monoxide series discussed.

  19. Cumulative exposure to carbon monoxide during the day

    Joumard, R. (INRETS, 69 - Bron (FR))

    The carbon monoxide, CO, has the advantage of being very easily and accurately measured under various conditions. In addition, it allows the translation of CO concentrations into their biological effects. The cumulative CO exposure should be considered according to current environment conditions during a given period of life, e.g. the day. In addition, the translation of concentrations and exposure times of CO fixed on blood haemoglobine (carboxyhaemoglobine) depends on physiological factors such as age, size, sex, or physical activity. This paper gives some examples of CO exposure translated into curves of carboxyhaemoglobine: case of 92 persons whose schedule was studied in details, of customs officers whose exposure was measured during one week, or other theoretical cases. In all the cases studied, smoking is by far the first factor of pollution by carbon monoxide. If not considering this case, the CO contents observed are preoccupying for sensitive subjects (in particular children) only in very rare cases. Furthermore, this approach allows the assessment of maximal allowable concentrations during specific exposures (work, e.g. in a tunnel) by integrating them into normal life conditions and population current exposure.

  20. 40 CFR 51.241 - Nonattainment areas for carbon monoxide and ozone.

    2010-07-01

    ... Intergovernmental Consultation Agency Designation § 51.241 Nonattainment areas for carbon monoxide and ozone. (a... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Nonattainment areas for carbon monoxide and ozone. 51.241 Section 51.241 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED...

  1. Carbon monoxide may be an important molecule in migraine and other headaches

    Arngrim, Nanna; Schytz, Henrik W; Hauge, Mette K

    2014-01-01

    INTRODUCTION: Carbon monoxide was previously considered to just be a toxic gas. A wealth of recent information has, however, shown that it is also an important endogenously produced signalling molecule involved in multiple biological processes. Endogenously produced carbon monoxide may thus play...

  2. CW-Laser-Induced Solid-State Reactions in Mixed Micron-Sized Particles of Silicon Monoxide and Titanium Monoxide: Nano-Structured Composite with Visible Light Absorption

    Křenek, T.; Tesař, J.; Kupčík, Jaroslav; Netrvalová, M.; Pola, M.; Jandová, Věra; Pokorná, Dana; Cuřínová, Petra; Bezdička, Petr; Pola, Josef

    2017-01-01

    Roč. 27, č. 6 (2017), s. 1640-1648 ISSN 1574-1443 Institutional support: RVO:61388980 ; RVO:67985858 Keywords : Cw CO2 laser heating * IR laser imaging * Silicon monoxide * Solid state redox reactions * Ti/Si/O composite * Titanium monoxide Subject RIV: CA - Inorganic Chemistry; CI - Industrial Chemistry, Chemical Engineering (UCHP-M) OBOR OECD: Inorganic and nuclear chemistry; Chemical process engineering (UCHP-M) Impact factor: 1.577, year: 2016

  3. Method of removing nitrogen monoxide from a nitrogen monoxide-containing gas using a water-soluble iron ion-dithiocarbamate, xanthate or thioxanthate

    Liu, D. Kwok-Keung; Chang, Shih-Ger

    1987-08-25

    The present invention relates to a method of removing of nitrogen monoxide from a nitrogen monoxide-containing gas which method comprises contacting a nitrogen oxide-containing gas with an aqueous solution of water soluble organic compound-iron ion chelate complex. The NO absorption efficiency of ferrous urea-dithiocarbamate and ferrous diethanolamine-xanthate as a function of time, oxygen content and solution ph is presented. 3 figs., 1 tab.

  4. Long-Term Outcomes of Laser Prostatectomy for Storage Symptoms: Comparison of Serial 5-Year Followup Data between High Performance System Photoselective Vaporization and Holmium Laser Enucleation of the Prostate.

    Cho, Min Chul; Song, Won Hoon; Park, Juhyun; Cho, Sung Yong; Jeong, Hyeon; Oh, Seung-June; Paick, Jae-Seung; Son, Hwancheol

    2018-01-09

    We compared long-term storage symptom outcomes between photoselective laser vaporization of the prostate with a 120 W high performance system and holmium laser enucleation of the prostate. We also determined factors influencing postoperative improvement of storage symptoms in the long term. Included in our study were 266 men, including 165 treated with prostate photoselective laser vaporization using a 120 W high performance system and 101 treated with holmium laser enucleation of the prostate, on whom 60-month followup data were available. Outcomes were assessed serially 6, 12, 24, 36, 48 and 60 months postoperatively using the International Prostate Symptom Score, uroflowmetry and the serum prostate specific antigen level. Postoperative improvement in storage symptoms was defined as a 50% or greater reduction in the subtotal storage symptom score at each followup visit after surgery compared to baseline. Improvements in frequency, urgency, nocturia, subtotal storage symptom scores and the quality of life index were maintained up to 60 months after photoselective laser vaporization or holmium laser enucleation of the prostate. There was no difference in the degree of improvement in storage symptoms or the percent of patients with postoperative improvement in storage symptoms between the 2 groups throughout the long-term followup. However, the holmium laser group showed greater improvement in voiding symptoms and quality of life than the laser vaporization group. On logistic regression analysis a higher baseline subtotal storage symptom score and a higher BOOI (Bladder Outlet Obstruction Index) were the factors influencing the improvement in storage symptoms 5 years after prostate photoselective laser vaporization or holmium laser enucleation. Our serial followup data suggest that storage symptom improvement was maintained throughout the long-term postoperative period for prostate photoselective laser vaporization with a 120 W high performance system and holmium

  5. Robotic Assisted Simple Prostatectomy versus Holmium Laser Enucleation of the Prostate for Lower Urinary Tract Symptoms in Patients with Large Volume Prostate: A Comparative Analysis from a High Volume Center.

    Umari, Paolo; Fossati, Nicola; Gandaglia, Giorgio; Pokorny, Morgan; De Groote, Ruben; Geurts, Nicolas; Goossens, Marijn; Schatterman, Peter; De Naeyer, Geert; Mottrie, Alexandre

    2017-04-01

    We report a comparative analysis of robotic assisted simple prostatectomy vs holmium laser enucleation of the prostate in patients who had benign prostatic hyperplasia with a large volume prostate (greater than 100 ml). A total of 81 patients underwent robotic assisted simple prostatectomy and 45 underwent holmium laser enucleation of the prostate in a 7-year period. Patients were preoperatively assessed with transrectal ultrasound and uroflowmetry. Functional parameters were assessed postoperatively during followup. Perioperative outcomes included operative time, postoperative hemoglobin, catheterization time and hospitalization. Complications were reported according to the Clavien-Dindo classification. Compared to the holmium laser enucleation group, patients treated with prostatectomy were significantly younger (median age 69 vs 74 years, p = 0.032) and less healthy (Charlson comorbidity index 2 or greater in 62% vs 29%, p = 0.0003), and had a lower rate of suprapubic catheterization (23% vs 42%, p = 0.028) and a higher preoperative I-PSS (International Prostate Symptom Score) (25 vs 21, p = 0.049). Both groups showed an improvement in the maximum flow rate (15 vs 11 ml per second, p = 0.7), and a significant reduction in post-void residual urine (-73 vs -100 ml, p = 0.4) and I-PSS (-20 vs -18, p = 0.8). Median operative time (105 vs 105 minutes, p = 0.9) and postoperative hemoglobin (13.2 vs 13.8 gm/dl, p = 0.08) were similar for robotic assisted prostatectomy and holmium laser enucleation, respectively. Median catheterization time (3 vs 2 days, p = 0.005) and median hospitalization (4 vs 2 days, p = 0.0001) were slightly shorter in the holmium laser group. Complication rates were similar with no Clavien grade greater than 3 in either group. Our results from a single center suggest comparable outcomes for robotic assisted simple prostatectomy and holmium laser enucleation of the prostate in patients with a large volume prostate. These findings require

  6. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been o...

  7. A primary exploration to quasi-two-dimensional rare-earth ferromagnetic particles: holmium-doped MoS2 sheet as room-temperature magnetic semiconductor

    Chen, Xi; Lin, Zheng-Zhe

    2018-05-01

    Recently, two-dimensional materials and nanoparticles with robust ferromagnetism are even of great interest to explore basic physics in nanoscale spintronics. More importantly, room-temperature magnetic semiconducting materials with high Curie temperature is essential for developing next-generation spintronic and quantum computing devices. Here, we develop a theoretical model on the basis of density functional theory calculations and the Ruderman-Kittel-Kasuya-Yoshida theory to predict the thermal stability of two-dimensional magnetic materials. Compared with other rare-earth (dysprosium (Dy) and erbium (Er)) and 3 d (copper (Cu)) impurities, holmium-doped (Ho-doped) single-layer 1H-MoS2 is proposed as promising semiconductor with robust magnetism. The calculations at the level of hybrid HSE06 functional predict a Curie temperature much higher than room temperature. Ho-doped MoS2 sheet possesses fully spin-polarized valence and conduction bands, which is a prerequisite for flexible spintronic applications.

  8. Development of phosphate glass microspheres containing holmium for selective internal radiotherapy; Desenvolvimento de microesferas de vidro fosfato contendo holmio para uso em radioterapia interna seletiva

    Barros Filho, Eraldo Cordeiro

    2016-11-01

    The selective internal radiotherapy is an alternative for some kinds of cancer as the hepatocellular carcinoma (HCC) or primary liver cancer treatment. In this treatment, glass or polymer microspheres containing radionuclides inside their structure are introduced in the liver through hepatic artery and trapped at the arterioles that feed the tumor. In this work, the development of phosphate glasses containing holmium for production of microspheres and their application in Brazil are proposed. The developed glasses presented suitable chemical durability, density of 2,7(3) g/cm{sup 3}, high thermal stability and the impurities contained therein do not preclude the treatment. The microspheres were produced by the flame method and the gravitational fall method, and were characterized by means of several techniques to evaluate shape, average particle size, activity and biocompatibility suitable for selective internal radiotherapy. Based in the main results, the submission to in vivo tests is proposed. (author)

  9. Flexible ureterorenoscopy (F-URS) with holmium laser versus extracorporeal shock wave lithotripsy (ESWL) for treatment of renal stone <2 cm: a meta-analysis.

    Mi, Yuanyuan; Ren, Kewei; Pan, Haiyan; Zhu, Lijie; Wu, Sheng; You, Xiaoming; Shao, Hongbao; Dai, Feng; Peng, Tao; Qin, Feng; Wang, Jian; Huang, Yi

    2016-08-01

    The objective of the study was to systematically review the efficacy and safety of flexible ureterorenoscopy (F-URS) with holmium laser versus extracorporeal shock wave lithotripsy (ESWL) for the treatment of renal stone ESWL (WMD = 2.13, 95 % CI 1.13-4.00, P = 0.02). F-URS is associated with higher SFR, lower APR and RR than ESWL. F-URS is a safe and effective procedure. It can successfully treat patients with stones for 1-2 cm, especially for lower pole stone, without increasing complications, operative time and hospital stay. F-URS can be used as an alternative treatment to ESWL in selected cases with larger renal stones. However, further randomized trials are needed to confirm these findings.

  10. Vaporization study on vanadium monoxide and two-phase mixture of vanadium and vanadium monoxide by mass-spectrometric method

    Banchorndhevakul, W.; Matsui, Tsuneo; Naito, Keiji

    1986-01-01

    The vapor pressures over single phase vanadium monoxide VO 1.022 (s) and the two-phase mixture of vanadium metal (β phase) and vanadium monoxide were measured by mass-spectrometric method in the temperature range of 1,803 ∼ 1,990 and 1,703 ∼ 1,884 K, respectively. The main gas species over both systems were found to be VO(g) and V(g). The vapor pressure of VO(g) over the two-phase mixture of V(s) and VO(s) was a little lower than that over single phase VO(s). The vapor pressure of V(g) over the two-phase mixture was nearly equal to that over single phase. From the vapor pressure data, the enthalpies of vaporization, the enthalpies of formation for VO(g) and V(g) and the dissociation energy of VO(g) were determined. The oxygen partial pressure was calculated as a function of temperature from the vapor pressures of VO(g) and V(g), from which the partial molar enthalpies and entropies of oxygen in both systems were obtained. (author)

  11. Use of the Stone Cone for prevention of calculus retropulsion during holmium:YAG laser lithotripsy: case series and review of the literature.

    Eisner, Brian H; Dretler, Stephen P

    2009-01-01

    Stone retropulsion during ureteroscopic lithotripsy leads to additional procedures for residual calculi. The Stone Cone (Boston Scientific, Natick, Mass., USA) is a device designed to prevent stone migration. To determine the incidence of calculus retropulsion and additional procedures after ureteroscopy with intracorporeal lithotripsy while using the Stone Cone. A retrospective review of patients with obstructing ureteral calculi who underwent ureteroscopy and holmium:YAG laser lithotripsy using the Stone Cone as a backstop over a 3-year period at an academic medical center was performed. 133 patients underwent ureteroscopy with holmium:YAG laser lithotripsy using the Stone Cone to prevent calculus retroplusion. Success was defined as no residual fragments >2 mm in size, no changes from semirigid to flexible ureteroscope, and no additional procedures. Post-operative imaging was abdominal plain radiography or computed tomography. A MEDLINE search was performed to indentify all English clinical studies of the Stone Cone. Of the 133 uses of the Stone Cone, there were 2 (1.5%) residual retropulsed fragments >2 mm which required an additional procedure. There were no changes to flexible ureteroscope secondary to stone retropulsion in 105 cases of semirigid ureteroscopy. There was no instance of ureteral obstruction from residual 2-mm fragments. There were no ureteral strictures or hydronephrosis among 91 patients with long-term follow-up imaging. A review of the literature was performed which yielded 4 clinical publications and 90 reported cases using the Stone Cone with 100% success. Two of these studies showed statistically significant improvement when compared with control patients. The Stone Cone minimized stone retropulsion during ureteroscopic laser lithotripsy. The Stone Cone offers the urologist greater certainty during ureteroscopy and may decrease the number of clinically significant residual calculi. Copyright 2009 S. Karger AG, Basel.

  12. 40 CFR 415.330 - Applicability; description of the carbon monoxide and by-product hydrogen production subcategory.

    2010-07-01

    ... carbon monoxide and by-product hydrogen production subcategory. 415.330 Section 415.330 Protection of... MANUFACTURING POINT SOURCE CATEGORY Carbon Monoxide and By-Product Hydrogen Production Subcategory § 415.330 Applicability; description of the carbon monoxide and by-product hydrogen production subcategory. The provisions...

  13. 40 CFR 89.112 - Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission standards.

    2010-07-01

    ....112 Oxides of nitrogen, carbon monoxide, hydrocarbon, and particulate matter exhaust emission... emissions of oxides of nitrogen, carbon monoxide, hydrocarbon, and nonmethane hydrocarbon are measured using... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Oxides of nitrogen, carbon monoxide...

  14. Lethal carbon monoxide toxicity in a concrete shower unit.

    Heath, Karen; Byard, Roger W

    2018-05-23

    A 47-year-old previously-well woman was found dead on the floor of a shower cubicle on a property in rural South Australia. The impression of the attending doctor and police was of collapse due to natural disease. Although there was significant stenosing coronary artery atherosclerosis found at autopsy, cherry pink discoloration of tissues prompted measurement of the blood carboxyhemoglobin level which was found to be 55%. The source of the gas was a poorly-maintained hot water heater that was mounted on the inside wall of the shower. Construction of the shower using an impermeable concrete rain water tank had caused gas accumulation when the water heater malfunctioned. Had lethal carbon monoxide exposure not been identified others using the same shower unit would also have been at risk.

  15. The effect of carbon monoxide on planetary haze formation

    Hörst, S. M.; Tolbert, M. A, E-mail: sarah.horst@colorado.edu [Cooperative Institute for Research in Environmental Sciences, University of Colorado, Boulder, CO (United States)

    2014-01-20

    Organic haze plays a key role in many planetary processes ranging from influencing the radiation budget of an atmosphere to serving as a source of prebiotic molecules on the surface. Numerous experiments have investigated the aerosols produced by exposing mixtures of N{sub 2}/CH{sub 4} to a variety of energy sources. However, many N{sub 2}/CH{sub 4} atmospheres in both our solar system and extrasolar planetary systems also contain carbon monoxide (CO). We have conducted a series of atmosphere simulation experiments to investigate the effect of CO on the formation and particle size of planetary haze analogues for a range of CO mixing ratios using two different energy sources, spark discharge and UV. We find that CO strongly affects both number density and particle size of the aerosols produced in our experiments and indicates that CO may play an important, previously unexplored, role in aerosol chemistry in planetary atmospheres.

  16. Carbon monoxide (CO) intoxication: Computerized tomography and magnetic resonance

    Benitez Gomez, S.; Aguilera Navarro, J.M.; Gonzalez Garcia, A.; Gonzalez Marcos, J.R.; Fernandez Cruz, J.

    1993-01-01

    We present a case of acute carbon monoxide (CO) intoxication in a previously healthy 13-year-old girl, who was found in the bathroom, unconscious and with the gas-burning hot water thank operating. The neuroradiological study showed bilateral, symmetrical cortical and subcortical parietooccipital and temporal lesions as well as damage to the basal lymph nodes. These lesions were related to the anoxic situation induced by this type of intoxication. Clinicoradiological follow-up included CT and MR sequences over a period of 10 months. In this cases, we stress the greater sensitivity of MR in the early detection of the characteristic lesions in this situation and we analyze the evolution of the process. (Author)

  17. Investigation of Carbon Monoxide Adsorption on Cationic Gold- Palladium Clusters

    Chen, Yang-Mei; Kuang, Xiao-Yu; Sheng, Xiao-Wei; Wang, Huai-Qian; Shao, Peng; Zhong, Min-Ming

    2013-11-01

    Density functional calculations have been performed for the carbon monoxide molecule adsorption on AunPd+m(n+m ≤ 6) clusters. In the process of CO adsorption, small Au clusters and Pd clusters tend to be an Au atom and three Pd atoms adsorption, respectively. For the mixed Au-Pd clusters, an Au atom, a Pd atom, two atoms consisted of an Au atom and a Pd atom, two Pd atoms, and three Pd atoms adsorption structures are displayed. The highest occupied molecular orbital-lowest unoccupied molecular orbital (HOMO-LUMO) gaps and natural bond orbital charge population are calculated. Moreover, CO adsorption energy, CO stretching frequency, and CO bond length (upon adsorption) are also analysed in detail. The results predict that the adsorption strength of Au clusters with CO and the C-O vibration strength is enhanced and reduced after doping of Pd in the AunPdmCO+ complexes, respectively

  18. Reactivity of niobium cluster anions with nitrogen and carbon monoxide

    Mwakapumba, Joseph; Ervin, Kent M.

    1997-02-01

    Reactions of small niobium cluster anions, Nbn-(n = 2-7), with CO and N2 are investigated using a flow tube reactor (flowing afterglow) apparatus. Carbon monoxide chemisorption on niobium cluster anions occurs with faster reaction rates than nitrogen chemisorption on corresponding cluster sizes. N2 addition to niobium cluster anions is much more size-selective than is CO addition. These general trends follow those reported in the literature for reactions of neutral and cationic niobium clusters with CO and N2. Extensive fragmentation of the clusters is observed upon chemisorption. A small fraction of the larger clusters survive and sequentially add multiple CO or N2 units without fragmentation. However, chemisorption saturation is not reached at the experimentally accessible pressure and reagent concentration ranges. The thermochemistry of the adsorption processes and the nature of the adsorbed species, molecular or dissociated, are discussed.

  19. A divalent rare earth oxide semiconductor: Yttrium monoxide

    Kaminaga, Kenichi; Sei, Ryosuke [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan); Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hayashi, Kouichi [Department of Environmental and Materials Engineering, Nagoya Institute of Technology, Nagoya 466-8555 (Japan); Happo, Naohisa [School of Information Sciences, Hiroshima City University, Hiroshima 731-3194 (Japan); Tajiri, Hiroo [Japan Synchrotron Radiation Research Institute (JASRI)/SPring-8, Sayo 679-5198 (Japan); Oka, Daichi; Fukumura, Tomoteru, E-mail: tomoteru.fukumura.e4@tohoku.ac.jp [Department of Chemistry, Tohoku University, Sendai 980-8578 (Japan); Hasegawa, Tetsuya [Department of Chemistry, The University of Tokyo, Tokyo 113-0033 (Japan)

    2016-03-21

    Rare earth oxides are usually widegap insulators like Y{sub 2}O{sub 3} with closed shell trivalent rare earth ions. In this study, solid phase rock salt structure yttrium monoxide, YO, with unusual valence of Y{sup 2+} (4d{sup 1}) was synthesized in a form of epitaxial thin film by pulsed laser deposition method. YO has been recognized as gaseous phase in previous studies. In contrast with Y{sub 2}O{sub 3}, YO was dark-brown colored and narrow gap semiconductor. The tunable electrical conductivity ranging from 10{sup −1} to 10{sup 3} Ω{sup −1 }cm{sup −1} was attributed to the presence of oxygen vacancies serving as electron donor. Weak antilocalization behavior observed in magnetoresistance indicated significant role of spin-orbit coupling as a manifestation of 4d electron carrier.

  20. Ferromagnetic semiconductor-metal transition in heterostructures of europium monoxide

    Stollenwerk, Tobias; Kroha, Johann [Physikalisches Institut der Universitaet Bonn (Germany)

    2012-07-01

    Experiments on thin films of electron doped europium monoxide show a simultaneous ferromagnetic semiconductor-metal transition which goes along with a huge drop in resistivity over several orders of magnitude. Therefore, this material is a very promising candidate for spintronics applications. We have developed a theory which correctly predicts the simultaneous phase transition in thin films of electron doped EuO and the increase of the Curie temperature T{sub C} with doping concentration. The origin of the increased T{sub C} lies in the enhanced RKKY interaction between the localized 4f moments of the Eu atoms. Therefore, the phase transition is controlled by the population of the conduction band. We investigate the influence of film thickness and interface effects on the population of the conduction band and on the magnetic and electronic properties of the EuO film.

  1. UV-induced carbon monoxide emission from living vegetation

    Bruhn, Dan; Albert, Kristian Rost; Mikkelsen, Teis Nørgaard

    2013-01-01

    The global burden of carbon monoxide (CO) is rather uncertain. In this paper we address the potential for UV-induced CO emission by living terrestrial vegetation surfaces. Real-time measurements of CO concentrations were made with a cavity enhanced laser spectrometer connected in closed loop...... to either an ecosystem chamber or a plant-leaf scale chamber. Leaves of all examined plant species exhibited emission of CO in response to artificial UV-radiation as well as the UV-component of natural solar radiation. The UV-induced rate of CO emission exhibited a rather low dependence on temperature......, indicating an abiotic process. The emission of CO in response to the UV-component of natural solar radiation was also evident at the ecosystem scale....

  2. Four deaths due to carbon monoxide poisoning in car washes.

    Carson, H J; Stephens, P J

    1999-09-01

    In a period of 13 months, three separate incidents of lethal carbon monoxide (CO) poisoning in closed car wash bays resulted in the deaths of 4 white men aged 20 to 36 years. Each man appears to have been intoxicated with mind-altering substances, which may impair judgment, perception of outside conditions, and self-awareness. All four died in winter months. For three men, the deaths were ruled accidental, and for the remaining man, the previous deaths appear to have provided a model for suicide. Warning signs may not be effective to prevent future CO deaths in car washes because of the possible role of intoxication. Mechanical or electronic methods to prevent a bay door from closing completely may be preferable.

  3. An Unusual Cause of Supraventricular Tachycardia: Acute Carbon Monoxide Poisoning

    Suat Zengin

    2014-03-01

    Full Text Available      Carbon monoxide (CO is a toxic gas produced by the incomplete combustion of carbon-containing compounds. Exposure to high concentrations of CO can be letha and is the most common cause of death from poisoning worldwide. Cardiac manifestations after exposure to CO, including myocardial ischemia, heart failure, and arrhythmias, have been reported. A 28-year-old a patient was admitted to our emergency department with altered consciousness as a consequence of acute domestic exposure to CO from a stove. His carboxyhemoglobin level was 39%. The oxygen treatment was started promptly, and therapeutic red cell exchange was performed. An electrocardiogram revealed supraventricular tachycardia (SVT, and an echocardiographic examination demonstrated normal cardiac functions. To the best of our knowledge, this study is the second to report a case of SVT attack due to acute CO intoxication. This paper discusses the management of this complication in patients poisoned with CO.

  4. [Etiology of combined inhalational hydrocyanic acid and carbon monoxide poisoning].

    Sigrist, T; Dirnhofer, R

    1979-01-01

    A young man was found dead in a kitchen, that was partly burnt. Autopsy revealed, as cause of death, a combined intoxication following inhalation of carbon monoxide and hydrocyanic acid. Own investigations on the pyrolysis of pieces of furniture found in the kitchen (plastic plates containing melamine and plates containing formaldehyde) showed, that hydrocyanic acid was liberated through combustion of such substances and inhaled by the victim. The poisoning picture is discussed, and discussion includes especially considerations on the peculiar sensitivity of the brain toward the action of hydrocyanic acid and the relative insensitivity of the heart muscle. It is thought that the cause of such sensitivity difference lies in the physiological differences of the intracellular energy production. Finally the dangers of combustion gases developing from burning plastic materials are reemphasized.

  5. 经皮肾穿刺钬激光碎石术后疼痛的护理干预%Nursing intervention of postoperative pain after percutaneous nephrolithotomy holmium laser

    白玫; 乔够梅; 杏玲芝; 陆皓

    2012-01-01

    目的:探讨护理干预对减轻经皮肾穿刺钬激光碎石术后疼痛的效果.方法:随机将264例经皮肾穿刺钬激光碎石术患者分成干预组和对照组各132例.对照组患者给予经皮肾穿刺钬激光碎石术后常规护理,干预组在对照组的基础上进行一系列的护理干预.结果:干预组术后疼痛明显低于对照组(P<0.05).结论:护理干预在经皮肾穿刺钬激光碎石术后应用能明显减轻患者疼痛,加速患者术后康复,有利于护理质量的提高.%Objective:To study the nursing intervention on reducing percutaneous holmium laser effect of postoperative pain. Methods:264 patients randomized to percutaneous nephrolithotomy with holmium laser lithotripsy were divided into intervention group and control group of 132 cases at radom. The control group conventional percutaneous holmium laser lithotripsy postoperative care, intervention group were based on a series of nursing intervention. Results postoperative pain of intervention group was significantly lower than control group ( P <0.05 ). Conclusion: Nursing intervention in percutaneous holmium laser lithotripsy in patients with significantly reduced postoperative pain,accelerated postoperative recovery, is conducive to improving quality of care.

  6. Campaign to prevent carbon monoxide poisoning : fall-winter 2007-2008

    Lefebvre, B.; Chabot, L.; Gratton, J.; Lacoursiere, D.

    2009-01-01

    Quebec launched a public health campaign for the Montreal region to prevent carbon monoxide poisoning. The objectives of the campaign were to communicate the dangers of carbon monoxide poisoning, its potential sources, its effects on public health, and the means to prevent poisoning. Its purpose was to inform the public of the risks and strategies to be used in case of carbon monoxide poisoning and to lay out the merits of household carbon monoxide alarms. The communication was done by way of the media, in cooperation with community organizations and school boards. Other tools used in the campaign included the Internet, flyers and press releases. A poll taken in 2008 showed that 59 per cent of the respondents had one or more sources for carbon monoxide in their homes, including fireplaces, and that 28 per cent had a functioning alarm for carbon monoxide detection. A future survey will be held to follow-up on the evolution of the campaign. The development of various activities will help decrease the risk of carbon monoxide poisoning. tabs., figs.

  7. Content of carbon monoxide in the tissues of rats intoxicated with carbon monoxide in various conditions of acute exposure

    Sokal, J.A.; Majka, J.; Palus, J.

    1984-12-01

    Tissue carbon monoxide (CO) content was investigated in rats severely intoxicated with CO under various exposure conditions: 1% CO for 4 min, 0.4% CO for 40 min and 0.12% CO for 12 h. Extravascular CO was determined in the heart and skeletal muscles immediately after termination of exposure, and carboxymyoglobin (MbCO) percent saturation was calculated. Total brain CO was estimated immediately after termination of exposure and after the time periods of restitution. After the same exposure conditions, MbCO percent saturation was higher in the heart than in skeletal muscle. In both types of muscle, saturation on myoglobin (Mb) with CO depended on blood carboxyhemoglobin (HbCO) level and not on the duration of exposure. The time course of CO elimination was the same for blood and brain, irrespective of CO exposure conditions. The results obtained showed that acute CO intoxication induced by long duration exposures did not involve CO accumulation in the tissues.

  8. Study on the influence of carbon monoxide to the surface oxide layer of uranium metal

    Wang Xiaolin; Duan Rongliang; Fu Yibei; Xie Renshou; Zuo Changming; Zhao Chunpei; Chen Hong

    1997-01-01

    The influence of carbon monoxide to the surface oxide layer of uranium metal has been studied by X-ray photoelectron spectroscopy (XPS) and gas chromatography (GC). Carbon monoxide adsorption on the oxide layer resulted in U4f peak shifting to the lower binding energy. The content of oxygen in the oxide is decreased and the atomic ratio (O/U) is decreased by 7.2%. The amount of carbon dioxide in the atmosphere after the surface reaction is increased by 11.0%. The investigation indicates that the surface layer can prevent the further oxidation uranium metal in the atmosphere of carbon monoxide

  9. Influence of carbon monoxide to the surface layer of uranium metal and its oxides

    Wang Xiaoling; Fu Yibei; Xie Renshou; Huang Ruiliang

    1996-09-01

    The surface structures of uranium metal and triuranium octaoxide (U 3 O 8 ) and the influence of carbon monoxide to the surface layers have been studied by X-ray photoelectron spectroscopy (XPS). After exposure to carbon monoxide, contents of oxygen in the surface oxides of uranium metal and U 3 O 8 are decreased and O/U ratios decrease 7.2%, 8.0% respectively. The investigation indicated the surface layers of uranium metal and its oxides were forbidden to further oxidation in the atmosphere of carbon monoxide. (11 refs., 9 figs., 2 tabs.)

  10. MLS/Aura L2 Chlorine Monoxide (ClO) Mixing Ratio V002

    National Aeronautics and Space Administration — ML2CLO is the EOS Aura Microwave Limb Sounder (MLS) standard product for chlorine monoxide derived from radiances measured primarily by the 640 GHz radiometer. The...

  11. Mechanism of obtaining carbon monoxide and hydrogen during brown coal radiolysis. [Gamma radiation

    Rustamov, V R; Kurbanov, M A; Dzantiev, B T; Kerimov, V K; Musaeva, P F

    1982-05-01

    This article analyzes effects of gamma radiation on the yield of products of coal gasification: hydrogen and carbon monoxide. Samples of brown coal from the Kansk-Achins basin were treated by gamma radiation with cobalt 60 radiation source. Analyses show that accumulation of hydrogen and carbon monoxide in brown coal under influence of gamma radiation is characterized by a constant rate. Yields of carbon monoxide and hydrogen amount to 0.16 molecule/100 electro volt and 0.21 molecule/electro volt respectively. Reducing radiation dose from 2.5 to 0.7 millirad/h reduces yields of hydrogen and carbon monoxide. Increasing temperature of vacuum brown coal pyrolysis from 200 to 600 C causes decrease of hydrogen yield. Hydrogen yield decrease during temperature increase is caused by a high content of aromatic nuclei in the samples used in the radiolysis. (5 refs.)

  12. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). NewSearch

    1994-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 137 citations and includes a subject term index and title list.)

  13. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    NONE

    1995-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography.(Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  14. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection database). Published Search

    NONE

    1996-10-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  15. Carbon monoxide toxicity. (Latest citations from the Life Sciences Collection data base). Published Search

    1992-08-01

    The bibliography contains citations concerning the mechanism and clinical manifestations of carbon monoxide (CO) exposure, including the effects on the liver, cardiovascular, and nervous systems. Topics include studies of the carbon monoxide binding affinity with hemoglobin, measurement of carboxyhemoglobin in humans and various animal species, carbon monoxide levels resulting from tobacco and marijuana smoke, occupational exposure and the NIOSH (National Institute for Occupational Safety and Health) biological exposure index, symptomology and percent of blood CO, and intrauterine exposure. Air pollution, tobacco smoking, and occupational exposure are discussed as primary sources of carbon monoxide exposure. The effects of cigarette smoking on fetal development and health are excluded and examined in a separate bibliography. (Contains a minimum of 172 citations and includes a subject term index and title list.)

  16. Environmental variables and levels of exhaled carbon monoxide and carboxyhemoglobin in elderly people taking exercise.

    Salicio, Marcos Adriano; Mana, Viviane Aparecida Martins; Fett, Waléria Christiane Rezende; Gomes, Luciano Teixeira; Botelho, Clovis

    2016-04-01

    This article aims to analyze levels of exhaled carbon monoxide, carboxyhemoglobinand cardiopulmonary variables in old people practicing exercise in external environments, and correlate them with climate and pollution factors. Temporal ecological study with118 active elderly people in the city of Cuiabá, in the state of Mato Grosso, Brazil. Data were obtained on use of medication, smoking, anthropometric measurements, spirometry, peak flow, oxygen saturation, heart rate, exhaled carbon monoxide, carboxyhemoglobin, climate, number of farm fires and pollution. Correlations were found between on the one hand environmental temperature, relative humidity of the air and number of farmers' fires, and on the other hand levels of carbon monoxide exhaled and carboxyhemoglobin (p carboxyhemoglobin and heart rate. There is thus a need for these to be monitored during exercise. The use of a carbon monoxide monitor to evaluate exposure to pollutants is suggested.

  17. Four-electron deoxygenative reductive coupling of carbon monoxide at a single metal site

    Buss, Joshua A.; Agapie, Theodor

    2016-01-01

    Carbon dioxide is the ultimate source of the fossil fuels that are both central to modern life and problematic: their use increases atmospheric levels of greenhouse gases, and their availability is geopolitically constrained. Using carbon dioxide as a feedstock to produce synthetic fuels might, in principle, alleviate these concerns. Although many homogeneous and heterogeneous catalysts convert carbon dioxide to carbon monoxide, further deoxygenative coupling of carbon monoxide to generate useful multicarbon products is challenging. Molybdenum and vanadium nitrogenases are capable of converting carbon monoxide into hydrocarbons under mild conditions, using discrete electron and proton sources. Electrocatalytic reduction of carbon monoxide on copper catalysts also uses a combination of electrons and protons, while the industrial Fischer-Tropsch process uses dihydrogen as a combined source of electrons and electrophiles for carbon monoxide coupling at high temperatures and pressures. However, these enzymatic and heterogeneous systems are difficult to probe mechanistically. Molecular catalysts have been studied extensively to investigate the elementary steps by which carbon monoxide is deoxygenated and coupled, but a single metal site that can efficiently induce the required scission of carbon-oxygen bonds and generate carbon-carbon bonds has not yet been documented. Here we describe a molybdenum compound, supported by a terphenyl-diphosphine ligand, that activates and cleaves the strong carbon-oxygen bond of carbon monoxide, enacts carbon-carbon coupling, and spontaneously dissociates the resulting fragment. This complex four-electron transformation is enabled by the terphenyl-diphosphine ligand, which acts as an electron reservoir and exhibits the coordinative flexibility needed to stabilize the different intermediates involved in the overall reaction sequence. We anticipate that these design elements might help in the development of efficient catalysts for

  18. Contributions of distinct gold species to catalytic reactivity for carbon monoxide oxidation

    Guo, Li-Wen; Du, Pei-Pei; Fu, Xin-Pu; Ma, Chao; Zeng, Jie; Si, Rui; Huang, Yu-Ying; Jia, Chun-Jiang; Zhang, Ya-Wen; Yan, Chun-Hua

    2016-11-01

    Small-size (carbon monoxide at room temperature, by the aid of in situ X-ray absorption fine structure analysis and in situ diffuse reflectance infrared Fourier transform spectroscopy. We find that the metallic gold component in clusters or particles plays a much more critical role as the active site than the cationic single-atom gold species for the room-temperature carbon monoxide oxidation reaction.

  19. Influence of cation size and surface coverage upon the infrared spectrum of carbon monoxide

    Huang, Jimin

    1991-01-01

    Adsorbed carbon monoxide is utilized as a double layer probe molecule because of its strong absorption in infrared region and because of the high sensitivity of the carbon-oxygen bond to changes in the environment local to the electrode surface. Potential Difference Infrared Spectroscopy was used to investigate the structural behavior of CO adsorbed on a platinum electrode. Carbon monoxide was found to be exclusively linear-bonded on platinum electrode in the presence of tetran...

  20. Selected constituents in the smokes of foreign commercial cigaretts: tar, nicotine, carbon monoxide, and carbon dioxide

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    The tar, nicotine, carbon monoxide, and carbon dioxide contents of the smokes of 220 brands of foreign commercial cigarettes are reported. In some instances, filter cigarettes of certain brands were found to deliver as much or more smoke constituents than their nonfilter counterparts. Also, data indicated that there can be a great variation in the tar, nicotine, or carbon monoxide content of the smoke of samples of a given brand of cigarettes, depending on the nation in which they are purchased. 24 tables.

  1. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    Inui, Y. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)]. E-mail: inui@eee.tut.ac.jp; Urata, A. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Ito, N. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Nakajima, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan); Tanaka, T. [Department of Electrical and Electronic Engineering, Toyohashi University of Technology, Tempaku-cho, Toyohashi 441-8580 (Japan)

    2006-08-15

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide.

  2. Optimization of mass flow rate in RGTT200K coolant purification for Carbon Monoxide conversion process

    Sumijanto; Sriyono

    2016-01-01

    Carbon monoxide is a species that is difficult to be separated from the reactor coolant helium because it has a relatively small molecular size. So it needs a process of conversion from carbon monoxide to carbondioxide. The rate of conversion of carbon monoxide in the purification system is influenced by several parameters including concentration, temperature and mass flow rate. In this research, optimization of the mass flow rate in coolant purification of RGTT200K for carbon monoxide conversion process was done. Optimization is carried out by using software Super Pro Designer. The rate of reduction of reactant species, the growth rate between the species and the species products in the conversion reactions equilibrium were analyzed to derive the mass flow rate optimization of purification for carbon monoxide conversion process. The purpose of this study is to find the mass flow rate of purification for the preparation of the basic design of the RGTT200K coolant helium purification system. The analysis showed that the helium mass flow rate of 0.6 kg/second resulted in an un optimal conversion process. The optimal conversion process was reached at a mass flow rate of 1.2 kg/second. A flow rate of 3.6 kg/second – 12 kg/second resulted in an ineffective process. For supporting the basic design of the RGTT200K helium purification system, the mass flow rate for carbon monoxide conversion process is suggested to be 1.2 kg/second. (author)

  3. Carbon monoxide exposure in households in Ciudad Juárez, México.

    Montoya, Teresa; Gurian, Patrick L; Velázquez-Angulo, Gilberto; Corella-Barud, Verónica; Rojo, Analila; Graham, Jay P

    2008-03-01

    This study assessed exposure to carbon monoxide from gas and wood heater emissions in a sample of 64 households in peri-urban residential areas in Ciudad Juárez, Chihuahua, México. Indoor and outdoor carbon monoxide concentrations and temperatures were monitored for a continuous period of 1 week at 1 and 6-min intervals, respectively. The moving average carbon monoxide concentrations were compared to the World Health Organization (WHO) standards for carbon monoxide. Sixty-seven percent of households with gas heaters and 60% of households with wood heaters exceeded a health-based standard at some point during the monitoring. The difference between indoor and outdoor temperatures was modestly correlated with average carbon monoxide exposure (r=0.35, p-value h standard of 9ppm (odds ratio=5.1, p-value=0.031). These results highlight the need for further efforts to identify and mitigate potentially hazardous carbon monoxide exposures, particularly in moderate-income countries with cooler climates.

  4. Performance simulation of planar SOFC using mixed hydrogen and carbon monoxide gases as fuel

    Inui, Y.; Urata, A.; Ito, N.; Nakajima, T.; Tanaka, T.

    2006-01-01

    The authors investigate in detail the influence of the mixing ratio of hydrogen and carbon monoxide in the fuel on the cell performance of the SOFC through numerical simulations for a single cell plate of the co-flow type planar cell. It is made clear that the cell performance is almost the same and excellent, independent of the mixing ratio of hydrogen and carbon monoxide under the nominal operating condition. The electromotive force of the hydrogen rich fuel gas is a little higher than that of the carbon monoxide rich fuel gas. The internal voltage drop in the cell decreases as the fraction of carbon monoxide becomes high. Since the value of the single cell voltage is determined by the balance of these two phenomena, the lowering of the electromotive force is dominant and the single cell voltage of the hydrogen rich fuel gas is higher when the inlet gas temperature is high, whereas the voltage drop reduction is dominant and the single cell voltage of the carbon monoxide rich fuel gas is higher when the temperature is low. The effect of the additional gases of water vapor and carbon dioxide is restricted to the single cell voltage shift, and the qualitative dependence of the single cell voltage on the inlet gas temperature is determined by the mixing ratio of hydrogen and carbon monoxide

  5. Metallic and insulating 3d transition-element monoxides and their stability

    Johansson, H.B.

    1977-01-01

    The binding properties of the 3d monoxides are studied in detail, and it is shown that the metallic character of TiO and VO is directly reflected in their heat of formation. The same holds true for NbO. From a stability analysis of the 3d monoxides versus decomposition, it is found that TiO, VO, and FeO are close to an instability. Further, it can be concluded that both ScO and CrO must be very near existence. The general occurrence of transition-metal monoxides is shown to be directly correlated with ionic properties of the transition elements. An investigation of the absorption edge in the 3d monoxides is also undertaken. The importance of the crystal-field splitting is noticed, and it is shown that the heat of formation of the monoxides can be used to derive the crystal-field parameter Δ. The change from a delocalized to a localized behavior of the d electrons in the 3d monoxides is compared with a similar change of the f electrons in the actinides. Some similarities between these two series of materials are pointed out

  6. Carbon Monoxide Epidemic Among Immigrant Populations: King County, Washington, 2006

    Kwan-Gett, Tao; Hampson, Neil B.; Baer, Atar; Shusterman, Dennis; Shandro, Jamie R.; Duchin, Jeffrey S.

    2009-01-01

    Objectives. We investigated an outbreak of carbon monoxide (CO) poisoning after a power outage to determine its extent, identify risk factors, and develop prevention measures. Methods. We reviewed medical records and medical examiner reports of patients with CO poisoning or related symptoms during December 15 to 24, 2006. We grouped patients into households exposed concurrently to a single source of CO. Results. Among 259 patients with CO poisoning, 204 cases were laboratory confirmed, 37 were probable, 10 were suspected, and 8 were fatal. Of 86 households studied, 58% (n = 50) were immigrant households from Africa (n = 21), Asia (n = 15), Latin America (n = 10), and the Middle East (n = 4); 34% (n = 29) were US-born households. One percent of households was European (n = 1), and the origin for 7% (n = 6) was unknown. Charcoal was the most common fuel source used among immigrant households (82%), whereas liquid fuel was predominant among US-born households (34%). Conclusions. Educational campaigns to prevent CO poisoning should consider immigrants’ cultural practices and languages and specifically warn against burning charcoal indoors and incorrect ventilation of gasoline- or propane-powered electric generators. PMID:19608962

  7. The neurotoxicology of carbon monoxide - Historical perspective and review.

    Sykes, Oliver T; Walker, Edward

    2016-01-01

    Carbon monoxide (CO) has been recognized as a poison for centuries, and remains one of the most common causes of both accidental and deliberate poisoning worldwide. Despite this, there are widespread misconceptions with regards to the mechanisms, diagnosis and outcomes of CO induced poisoning such as the idea that CO poisoning is rare; that carboxyhaemoglobin levels above 20% and loss of consciousness are required before nervous system damage ensues; and that the binding of CO to haemoglobin is the only mechanism of toxicity. Prevention and diagnosis of CO poisoning is hampered by the lack of awareness of CO as a cause of illness, among both the general public and healthcare professionals. To complicate matters further there is no standardized definition of CO poisoning. Carboxyhaemoglobin levels are often used as a marker of CO poisoning, yet plasma levels rapidly reduce upon removal of the source and are therefore an unreliable biomarker of exposure and tissue damage. Adverse neuropsychiatric outcomes after CO poisoning are difficult to define, especially as they fluctuate, mimic other non-specific complaints, and are not present in all survivors. This paper challenges a number of misconceptions about CO poisoning which can result in misdiagnosis, and consequently in mismanagement. We illustrate how recent developments in the understanding of CO toxicology explain the particular susceptibility of the central nervous system to the effects of CO exposure. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  8. Composition of amino acid using carbon monoxide. Amide carbonylation reaction

    Izawa, Kunisuke (Ajinomoto Co., Inc., Tokyo (Japan))

    1989-02-01

    Amide carbonylation reaction is a method to compose N-acyl-{alpha}-amino acid from aldehyde, carboxylic acid amide, and carbon monoxide in a phase and with high yield. Unlike the conventional Strecker reaction, this method does not use HCN which is in question on public pollution and does not require hydrolysis. This amide carbonylation reaction was discovered by Wakamatsu and others of Ajinomoto Co.,Ltd. Present application examples of this method are the composition of N-acetyl amino acid from the aldehyde class, the composition of N-Acyl amino acid from olefin, the composition of N-acyl or acetyl amino acid from the raw material of alcohol and the halide class, the composition of N-acyl or acetyl amino acid via the isomerization of epoxide and allyl alcohol, the composition of amino dicarboxylic acid, applying deoxidation of ring acid anhydride, the composition of N-acyl amino acid from the raw material of the amine class, the stereoselective composition of -substitution ring-{alpha}-amino acid, and the composition of amino aldehyde. 24 refs., 2 figs., 2 tabs.

  9. Monoxides of small terbium clusters: A density functional theory investigation

    Zhang, G. L.; Yuan, H. K., E-mail: yhk10@swu.edu.cn; Chen, H.; Kuang, A. L.; Li, Y.; Wang, J. Z.; Chen, J. [School of Physical Science and Technology, Southwest University, Chongqing 400715 (China)

    2014-12-28

    To investigate the effect of oxygen atom on the geometrical structures, electronic, and magnetic properties of small terbium clusters, we carried out the first-principles calculations on Tb{sub n}O (n = 1-14) clusters. The capping of an oxygen atom on one trigonal-facet of Tb{sub n} structures is always favored energetically, which can significantly improve the structural stability. The far-infrared vibrational spectroscopies are found to be different from those of corresponding bare clusters, providing a distinct signal to detect the characteristic structures of Tb{sub n}O clusters. The primary effect of oxygen atom on magnetic properties is to change the magnetic orderings among Tb atoms and to reduce small of local magnetic moments of the O-coordinated Tb atoms, both of which serve as the key reasons for the experimental magnetic evolution of an oscillating behavior. These calculations are consistent with, and help to account for, the experimentally observed magnetic properties of monoxide Tb{sub n}O clusters [C. N. Van Dijk et al., J. Appl. Phys. 107, 09B526 (2010)].

  10. Carbon monoxide: from toxin to endogenous modulator of cardiovascular functions

    R.A. Johnson

    1999-01-01

    Full Text Available Carbon monoxide (CO is a pollutant commonly recognized for its toxicological attributes, including CNS and cardiovascular effects. But CO is also formed endogenously in mammalian tissues. Endogenously formed CO normally arises from heme degradation in a reaction catalyzed by heme oxygenase. While inhibitors of endogenous CO production can raise arterial pressure, heme loading can enhance CO production and lead to vasodepression. Both central and peripheral tissues possess heme oxygenases and generate CO from heme, but the inability of heme substrate to cross the blood brain barrier suggests the CNS heme-heme oxygenase-CO system may be independent of the periphery. In the CNS, CO apparently acts in the nucleus tractus solitarii (NTS promoting changes in glutamatergic neurotransmission and lowering blood pressure. At the periphery, the heme-heme oxygenase-CO system can affect cardiovascular functions in a two-fold manner; specifically: 1 heme-derived CO generated within vascular smooth muscle (VSM can promote vasodilation, but 2 its actions on the endothelium apparently can promote vasoconstriction. Thus, it seems reasonable that the CNS-, VSM- and endothelial-dependent actions of the heme-heme oxygenase-CO system may all affect cardiac output and vascular resistance, and subsequently blood pressure.

  11. The Role of Oxygen Therapies in Carbon Monoxide Poisoning

    Suleyman Metin

    2011-08-01

    Full Text Available Due to climate and socio-economic issues in Turkey, the incidence of carbon monoxide (CO poisoning is high, especially in winter. Clinical manifestations may vary depending on the type of CO source, concentration and duration of exposure. The symptoms of CO poisoning predominantly manifest in lots of organs and systems with high oxygen utilization, especially the brain and the heart. The primary aim in oxygen therapy is to eliminate CO and to reduce its toxic effects. In this context, normobaric and hyperbaric oxygen therapy are used to achieve these goals. Normobaric oxygen (NBO treatment is an easily accessible and relatively not expensive modality, where hyperbaric oxygen (HBO therapy requires specific equipment, certified staff and is available only in some centers. Additionally, HBO treatment has several additional advantages over NBO treatment. Despite its benefits, it is compulsory to search for some criteria in selecting patients to be treated because of the limited availability and access of hyperbaric facilities. For an effective evaluation and an optimal treatment, advanced education of the healthcare professionals on the use of oxygen delivery modalities in the management of CO poisoning is imperative. In this review, it has been aimed to outline the significance of oxygen treatment modalities and to determine patient selection criteria for HBO treatment in the management of CO poisoning which continues to be an important threat to community health care. [TAF Prev Med Bull 2011; 10(4.000: 487-494

  12. Risk and protective behaviours for residential carbon monoxide poisoning.

    Rupert, Douglas J; Poehlman, Jon A; Damon, Scott A; Williams, Peyton N

    2013-04-01

    Unintentional, non-fire-related carbon monoxide (CO) poisoning is a leading cause of poisoning death and injury in the USA. Residential poisonings caused by faulty furnaces are the most common type of CO exposure. However, these poisonings are largely preventable with annual furnace inspections and CO alarm installation. This study aimed to identify the knowledge, attitudes and beliefs that might lead consumers to adopt these protective behaviours. In August 2009, four focus groups (n=29) were conducted with homeowners in Chicago, Illinois, USA, to identify the knowledge, attitudes and beliefs that lead consumers to adopt risk and protective behaviours. Discussions were transcribed and the findings were analysed using an ordered meta-matrix. Focus group participants were aware of CO poisoning and supported the idea of regular furnace inspections. However, few participants consistently scheduled professional inspections for fear of costly repairs and unscrupulous contractors. Participants often owned CO alarms, but many did not locate them properly, nor maintain them. Some participants confused CO and natural gas and were unsure how to react if a CO alarm sounds. Participants stated that incentives, such as discounts and inspector selection tips, would make them more likely to schedule furnace inspections. Participants also identified trustworthy sources for CO education, including realtors, fire departments, home insurance agents and local media outlets. Participants' residential CO risk behaviours are not random but driven by underlying knowledge, attitudes and beliefs. Correcting misperceptions, providing incentives and partnering with trustworthy sources might encourage greater consumer adoption of protective behaviours.

  13. Variability in hyperbaric oxygen treatment for acute carbon monoxide poisoning.

    Byrne, Brendan T; Lu, Jenny J; Valento, Matthew; Bryant, Sean M

    2012-01-01

    In patients with acute carbon monoxide (CO) poisoning, we have noted wide clinical variability in both criteria for hyperbaric oxygen (HBO2) treatment as well as HBO2 treatment regimens. Our aim was to survey Midwest hyperbaric centers for insight into specific criteria and protocols for treating acute CO toxicity with HBO2. Hyperbaric centers were identified from the published list of the Undersea and Hyperbaric Medical Society. Ninety-three centers from nine Midwestern states were contacted via telephone. A standard script was used to minimize surveyor bias. Thirty centers that treat CO poisonings were identified. One did not participate in the study. Nineteen reported a specific level of carboxyhemoglobin (COHb) that served as an independent indication for initiation of HBO2 treatment. Four centers used the COHb level as the exclusive indication for HBO2 treatment. Ten centers relied solely on reported symptoms, while the remaining centers used a combination of symptoms plus COHb levels. There were 19 separate treatment protocols. No uniform practice for either the initiation or implementation of HBO2 therapy for CO poisoning exists among U.S. Midwest hyperbaric centers responding to a survey. We see opportunity for specific targeted educational programs as well as further study.

  14. A Wireless and Batteryless Intelligent Carbon Monoxide Sensor.

    Chen, Chen-Chia; Sung, Gang-Neng; Chen, Wen-Ching; Kuo, Chih-Ting; Chue, Jin-Ju; Wu, Chieh-Ming; Huang, Chun-Ming

    2016-09-23

    Carbon monoxide (CO) poisoning from natural gas water heaters is a common household accident in Taiwan. We propose a wireless and batteryless intelligent CO sensor for improving the safety of operating natural gas water heaters. A micro-hydropower generator supplies power to a CO sensor without battery (COSWOB) (2.5 W at a flow rate of 4.2 L/min), and the power consumption of the COSWOB is only ~13 mW. The COSWOB monitors the CO concentration in ambient conditions around natural gas water heaters and transmits it to an intelligent gateway. When the CO level reaches a dangerous level, the COSWOB alarm sounds loudly. Meanwhile, the intelligent gateway also sends a trigger to activate Wi-Fi alarms and sends notifications to the mobile device through the Internet. Our strategy can warn people indoors and outdoors, thereby reducing CO poisoning accidents. We also believe that our technique not only can be used for home security but also can be used in industrial applications (for example, to monitor leak occurrence in a pipeline).

  15. The immunomodulatory role of carbon monoxide during transplantation

    Amano Mariane

    2013-01-01

    Full Text Available Abstract The number of organ and tissue transplants has increased worldwide in recent decades. However, graft rejection, infections due to the use of immunosuppressive drugs and a shortage of graft donors remain major concerns. Carbon monoxide (CO had long been regarded solely as a poisonous gas. Ultimately, physiological studies unveiled the endogenous production of CO, particularly by the heme oxygenase (HO-1 enzyme, recognizing CO as a beneficial gas when used at therapeutic doses. The protective properties of CO led researchers to develop uses for it, resulting in devices and molecules that can deliver CO in vitro and in vivo. The resulting interest in clinical investigations was immediate. Studies regarding the CO/HO-1 modulation of immune responses and their effects on various immune disorders gave rise to transplantation research, where CO was shown to be essential in the protection against organ rejection in animal models. This review provides a perspective of how CO modulates the immune system to improve transplantation and suggests its use as a therapy in the field.

  16. Carbon Monoxide Poisoning Cases Autopsied in South Marmara Region

    Filiz Eren

    2014-10-01

    Full Text Available Carbonmonoxide (CO related deaths, which are generally preventable accidents that include accidents due to the coal stoves and water heaters in bath at home, the mining accidents, and other accidents. CO accept as the most common cause of poisoning cases in many countries and its prominent feature is being a colorless, odorless and nonirritant gas. In the period from 2007 until the end of 2011, the autopsy records of the ........ of Turkey were reviewed. Over a period of 5 years a total of 5782 autopsies were done of which 218 involved CO poisoning, constituting 3,8 % of total cases. Information regarding age, sex, month, year, and as well as various aspects were examined. Study data were encoded with computer and Statistical analysis was performed using SPSS for windows program. Of the cases 76 were (34,9% female, 142 were (65,1% male and male/female ratio was 1,9. Of the cases average age was 46.8, range between 1 and 90 years. 57,8% of deaths were in winter markedly. The highest carboxyhemoglobin saturation was 92% in the blood. Poisoning due to CO leaks from coal heaters is an important problem in our country and surrounding regions. The mining accidents should be reduced by increasing safety in the workplace. We must more expend efforts to educate the public and prevent CO poisoning. Key words: Carbon monoxide, poisoning, autopsy.

  17. Carbon monoxide poisoning at motels, hotels, and resorts.

    Weaver, Lindell K; Deru, Kayla

    2007-07-01

    Each year, more than 200 people in the United States die from carbon monoxide (CO) poisoning. Poisoning has occurred at motels, hotels, and resorts. Congressional mandate requires smoke alarms in all guest rooms; however, smoke alarms do not detect CO. Data on patients poisoned at hotels, motels, and resorts were evaluated at a hyperbaric medicine service. In 2005, legal databases and online news databanks were searched to discover additional incidents. Only victims evaluated in hospitals or declared dead at the scene were included. Cases of intentional poisoning and poisoning from fires were excluded. Between 1989 and 2004, 68 incidents of CO poisoning occurring at hotels, motels, and resorts were identified, resulting in 772 accidentally poisoned: 711 guests, 41 employees or owners, and 20 rescue personnel. Of those poisoned, 27 died, 66 had confirmed sequelae, and 6 had sequelae resulting in a jury verdict. Lodging-operated, faulty room heating caused 45 incidents, pool/spa boilers 16, CO entrained from outdoors 5, and unreported sources caused 2 incidents. Public verdicts have averaged $4.8 million per incident (range, $1 million to $17.5 million). Poisoning occurred at hotels of all classes. Despite these incidents, most properties did not install CO alarms, and requirements for CO alarms at hotels, motels, and resorts are rare. Guests of motels, hotels, and resorts remain at risk for injury or death from CO poisoning. Measures to prevent CO poisoning of guests and employees of the lodging industry should be evaluated.

  18. Retrieval of tropospheric carbon monoxide for the MOPITT experiment

    Pan, Liwen; Gille, John C.; Edwards, David P.; Bailey, Paul L.; Rodgers, Clive D.

    1998-12-01

    A retrieval method for deriving the tropospheric carbon monoxide (CO) profile and column amount under clear sky conditions has been developed for the Measurements of Pollution In The Troposphere (MOPITT) instrument, scheduled for launch in 1998 onboard the EOS-AM1 satellite. This paper presents a description of the method along with analyses of retrieval information content. These analyses characterize the forward measurement sensitivity, the contribution of a priori information, and the retrieval vertical resolution. Ensembles of tropospheric CO profiles were compiled both from aircraft in situ measurements and from chemical model results and were used in retrieval experiments to characterize the method and to study the sensitivity to different parameters. Linear error analyses were carried out in parallel with the ensemble experiments. Results of these experiments and analyses indicate that MOPITT CO column measurements will have better than 10% precision, and CO profile measurement will have approximately three pieces of independent information that will resolve 3-5 tropospheric layers to approximately 10% precision. These analyses are important for understanding MOPITT data, both for application of data in tropospheric chemistry studies and for comparison with in situ measurements.

  19. General circulation model study of atmospheric carbon monoxide

    Pinto, J.P.; Yung, Y.L.; Rind, D.; Russell, G.L.; Lerner, J.A.; Hansen, J.E.; Hameed, S.

    1983-01-01

    The carbon monoxide cycle is studied by incorporating the known and hypothetical sources and sinks in a tracer model that uses the winds generated by a general circulation model. Photochemical production and loss terms, which depend on OH radical concentrations, are calculated in an interactive fashion. The computed global distribution and seasonal variations of CO are compared with observations to obtain constraints on the distribution and magnitude of the sources and sinks of CO, and on the tropospheric abundance of OH. The simplest model that accounts for available observations requires a low latitude plant source of about 1.3 x 10 15 g yr -1 , in addition to sources from incomplete combustion of fossil fuels and oxidation of methane. The globally averaged OH concentration calculated in the model is 7 x 10 5 cm -3 . Models that calculate globally averaged OH concentrations much lower than our nominal value are not consistent with the observed variability of CO. Such models are also inconsistent with measurements of CO isotopic abundances, which imply the existence of plant sources

  20. CT of the brain in acute carbon monoxide poisoning

    Ohno, Masato; Uchino, Akira; Hayashi, Kazuji; Nakata, Hajime.

    1988-01-01

    Cerebral computed tomographic (CT) findings of acute carbon monoxide (Co) poisoning were analized in thirty-six cases treated with hyperbraric oxygen therapy and their relationship with prognosis was evaluated. The cases were classified into there groups, early stage, interval form, and non-interval form groups. In all groups, the initial abnormality was low density areas presumably due to edema, demyelination and/or softening. It was seen in the globus pallidus and/or white matter. Following these initial changes, cerebral hemorrhage, ventricular dilatation, and cerebral atrophy developed in a few cases. The frequency of abnormal CT findings was higher in the interval form group (85 %) or non-interval group (83 %) than the early stage group (41 %). The prognosis was good in most cases with normal CT findings. The possibility of recovery diminished in the patients with abnormal CT findings. The prognosis was particularly poor in cases showing abnormality both in globus pallidus and white matter. We conclude that CT is useful not only for detecting the pathologic change but also for predicting the prognosis of the patient with acute Co poisoning. (author)

  1. Brain CT scan in acute carbon monoxide poisoning

    We, En-Huei

    1986-01-01

    The brain CT findings in 19 patients with acute carbon monoxide poisoning was analysed and the emphasis was placed on the relationship between CT findings and prognosis. Five had a normal manifestation in CT ; eight had the findings of ovoid or patchy low density area in globus pallidus, bilateral or unlateral, during the second day to fifth week after poisoning, and the low density areas were decreasing and blurring in edge in follow up and at last disappeared during 3 - 14 weeks in three cases of them ; nine showed the appearance of diffuse low density of white matter and of globus pallidus in some of them ; two had an appearance of brain atrophy. The pathology of CT findings mentioned above may be brain edema, necrosis, malacia and degeneration in gray matter and globus pallidus. The result suggested the cases with normal CT manifestation, cerebral edema and decreasing and disappearing low density area had a good prognosis, in contrary, the cases with persistant low density in globus pallidus had a poorer prognosis. (author)

  2. Heme oxygenase and carbon monoxide protect from muscle dystrophy.

    Chan, Mun Chun; Ziegler, Olivia; Liu, Laura; Rowe, Glenn C; Das, Saumya; Otterbein, Leo E; Arany, Zoltan

    2016-11-28

    Duchenne muscle dystrophy (DMD) is one of the most common lethal genetic diseases of children worldwide and is 100% fatal. Steroids, the only therapy currently available, are marred by poor efficacy and a high side-effect profile. New therapeutic approaches are urgently needed. Here, we leverage PGC-1α, a powerful transcriptional coactivator known to protect against dystrophy in the mdx murine model of DMD, to search for novel mechanisms of protection against dystrophy. We identify heme oxygenase-1 (HO-1) as a potential novel target for the treatment of DMD. Expression of HO-1 is blunted in the muscles from the mdx murine model of DMD, and further reduction of HO-1 by genetic haploinsufficiency worsens muscle damage in mdx mice. Conversely, induction of HO-1 pharmacologically protects against muscle damage. Mechanistically, HO-1 degrades heme into biliverdin, releasing in the process ferrous iron and carbon monoxide (CO). We show that exposure to a safe low dose of CO protects against muscle damage in mdx mice, as does pharmacological treatment with CO-releasing molecules. These data identify HO-1 and CO as novel therapeutic agents for the treatment of DMD. Safety profiles and clinical testing of inhaled CO already exist, underscoring the translational potential of these observations.

  3. Gene expression in rat striatum following carbon monoxide poisoning

    Shuichi Hara

    2017-06-01

    Full Text Available Carbon monoxide (CO poisoning causes brain damage, which is attenuated by treatment with hydrogen [1,2], a scavenger selective to hydroxyl radical (·≡OH [3]. This suggests a role of ·≡OH in brain damage due to CO poisoning. Studies have shown strong enhancement of ·≡OH production in rat striatum by severe CO poisoning with a blood carboxyhemoglobin (COHb level >70% due to 3000 ppm CO, but not less severe CO poisoning with a blood COHb level at approximately 50% due to 1000 ppm CO [4]. Interestingly, 5% O2 causes hypoxia comparable with that by 3000 ppm CO and produces much less •OH than 3000 ppm CO does [4]. In addition, cAMP production in parallel with ·≡OH production [5] might contribute to ·≡OH production [6]. It is likely that mechanisms other than hypoxia contribute to brain damage due to CO poisoning [7]. To search for the mechanisms, we examined the effects of 1000 ppm CO, 3000 ppm CO and 5% O2 on gene expression in rat striatum. All array data have been deposited in the Gene Expression Omnibus (GEO database under accession number GSE94780.

  4. Experimental and clinical study of chronic poisoning by carbon monoxide

    Thiele, H.; Gohlke, R.; Rothe, R.

    1973-01-01

    Animal and clinical tests on carbon monoxide-exposed subjects are described in an attempt to demonstrate the specific chronic action of CO. Rabbits exposed to 802 ppM and 284 ppM CO for 103 and 112 days, respectively, for 5 days a week showed carboxyhemoglobin values in the respective ranges of 2.5 to 11.9% and 2.5 to 8.3%. The macroscopic findings and gain in weight were normal, except for an increase by 20% and 14% in the weight of the liver. Dose-dependent increases in the hemoglobin and hematocrit levels, significant increases in the pyruvate level of the first group, and significant reductions of the cholinesterase, inorganic phosphate levels, hepatic lipase, phosphate, phosphatase, and cytochrome-C oxidase were observed. An increased cholinesterase level was found in brain homogenates. Inhibition of the glucose-6-phosphatase was observed. There is a specific damage due to CO in addition to merely the hypoxic effect. Clinical tests in humans with and without acute, subacute, or chronic exposure to CO revealed that acute and subacute poisoning have no additional pathogenic effect in chronic exposure, i.e., indicate the existence of primary chronic poisoning with CO.

  5. Subclinical carbon monoxide poisoning in our health area

    Arroyo, I.G.; Testa, A.F.; Sangrador, C.O.; Garcia, M.T.A.; Berrocal, J.L.S.; Pastor, N.R.; Martin, J.M.; Garcia, L.S.; Garcia, M.C.F.; Maire-Richard, E.G. [Hospital of Virgen Concha, Zamora (Spain)

    2003-08-01

    We present an observation study on the relationship between high levels of carboxyhemoglobin (COHB) and subclinical poisoning by carbon monoxide (CO) in our health area. The study was carried out in February and March 2000 in 228 over 18-year-old patients of both sexes who went to the Emergency Room for various reasons. After an informed consent was conceded, a venous blood sample was obtained in order to determine the level of COHB; later, we collected the anthropometric data, the data relative to the tobacco use, and the data of the type of heating at home. The values limit of the COHB obtained were the following: in non smokers, 1.9%; in 1-10 cigarettes/day smokers, 5.2%; in 11-20 cigarettes/day smokers, 6.9%; in {gt}20 cigarettes/day smokers, 9.6%. A COHB high level was observed in 25% of the patients regardless of the smoking habits, being the coal-dust slack brazier the source of most frequent exposure to CO.

  6. Magnetic resonance imaging of carbon monoxide poisoning in chronic stage

    Kojima, Shigeyuki; Kawamura, Mitsuru; Shibata, Noriyuki; Takahashi, Nobuyoshi; Hirayama, Keizo

    1986-01-01

    Magnetic resonance imaging (MRI) was evaluated in three patients with carbon monoxide (CO) poisoning in chronic stage by comparison with serial X-ray computed tomography (CT). In Case 1 and 3, no pallidal lesions believed to be the most common lesion of the gray matter in CO poisoning were found in the serial X-ray CT scans. In the other case (Case 2), the typical initial bilateral symmetrical low density areas in the globus pallidus were found to have decreased markedly in size and finally disappeared in the latter X-ray CT scan. But MRI using inversion recovery (IR) or spin echo (SE) pulse sequence clearly showed bilateral symmetrical decreased or increased signal intensity areas in the globus pallidus in all three cases. In Case 3, chronic CO poisoning was confirmed by the bilateral symmetrical pallidal lesions on MRI, although differential diagnosis was difficult. Furthermore, in Case 2, with pure alexia, MRI using IR or SE pulse sequence demonstrated a patchy decreased or increased signal intensity area in the subcortical white matter at the left angular gyrus, although X-ray CT scan showed no abnormal findings. MRI is useful in the diagnosis of CO poisoning, especially chronic CO poisoning, because necrosis, cavitation, demyelination, gliosis and so on due to hypoxia of CO poisoning were sensitively detected from changes in the proton density and the T1 or T2 relaxation time value on MRI. (J.P.N.)

  7. Computation of diatomic molecular spectra for selected transitions of aluminum monoxide, cyanide, diatomic carbon, and titanium monoxide

    Parigger, Christian G., E-mail: cparigge@tennessee.edu [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Woods, Alexander C.; Surmick, David M.; Gautam, Ghaneshwar; Witte, Michael J. [The University of Tennessee/University of Tennessee Space Institute, Center for Laser Applications, 411 B.H. Goethert Parkway, Tullahoma, TN 37388-9700 (United States); Hornkohl, James O. [Hornkohl Consulting, Tullahoma, TN 37388 (United States)

    2015-05-01

    Laser ablation studies with laser-induced breakdown spectroscopy (LIBS) typically emphasize atomic species yet fingerprints from molecular species can occur subsequently or concurrently. In this work, selected molecular transitions of aluminum monixide (AlO), diatomic carbon (C{sub 2}), cyanide (CN), and titanium monoxide (TiO) are accurately computed. Line strength tables are used to describe the radiative transitions of diatomic molecules primarily in the visible, optical region. Details are elaborated of the computational procedure that allows one to utilize diatomic spectra as a predictive and as a diagnostic tool. In order to create a computed spectrum, the procedure requires information regarding the temperature of the diatomic transitions along with other input such as the spectral resolution. When combined with a fitting algorithm to optimize such parameters, this procedure is used to infer information from an experimentally obtained spectrum. Furthermore, the programs and data files are provided for LIBS investigations that also reveal AlO, C{sub 2}, CN, and TiO diatomic spectra. - Highlights: • We present a program for fitting of molecular spectra. • This includes data base for AlO, C{sub 2}, CN, and TiO. • We discuss the details of the program including fitting. • We show computed examples and reference current work.

  8. Carbon monoxide poisoning-induced cardiomyopathy from charcoal at a barbecue restaurant: a case report.

    Kim, Hyun-Jun; Chung, Yun Kyung; Kwak, Kyeong Min; Ahn, Se-Jin; Kim, Yong-Hyun; Ju, Young-Su; Kwon, Young-Jun; Kim, Eun-A

    2015-01-01

    Acute carbon monoxide poisoning has important clinical value because it can cause severe adverse cardiovascular effects and sudden death. Acute carbon monoxide poisoning due to charcoal is well reported worldwide, and increased use of charcoal in the restaurant industry raises concern for an increase in occupational health problems. We present a case of carbon monoxide poisoning induced cardiomyopathy in a 47-year-old restaurant worker. A male patient was brought to the emergency department to syncope and complained of left chest pain. Cardiac angiography and electrocardiography were performed to rule out acute ischemic heart disease, and cardiac markers were checked. After relief of the symptoms and stabilization of the cardiac markers, the patient was discharged without any complications. Electrocardiography was normal, but cardiac angiography showed up to a 40% midsegmental stenosis of the right coronary artery with thrombotic plaque. The level of cardiac markers was elevated at least 5 to 10 times higher than the normal value, and the carboxyhemoglobin concentration was 35% measured at one hour after syncope. Following the diagnosis of acute carbon monoxide poisoning induced cardiomyopathy, the patient's medical history and work exposure history were examined. He was found to have been exposed to burning charcoal constantly during his work hours. Severe exposure to carbon monoxide was evident in the patient because of high carboxyhemoglobin concentration and highly elevated cardiac enzymes. We concluded that this exposure led to subsequent cardiac injury. He was diagnosed with acute carbon monoxide poisoning-induced cardiomyopathy due to an unsafe working environment. According to the results, the risk of exposure to noxious chemicals such as carbon monoxide by workers in the food service industry is potentially high, and workers in this sector should be educated and monitored by the occupational health service to prevent adverse effects.

  9. Autumn photoproduction of carbon monoxide in Jiaozhou Bay, China

    Ren, Chunyan; Yang, Guipeng; Lu, Xiaolan

    2014-06-01

    Carbon monoxide (CO) plays a significant role in global warming and atmospheric chemistry. Global oceans are net natural sources of atmospheric CO. CO at surface ocean is primarily produced from the photochemical degradation of chromophoric dissolved organic matter (CDOM). In this study, the effects of photobleaching, temperature and the origin (terrestrial or marine) of CDOM on the apparent quantum yields (AQY) of CO were studied for seawater samples collected from Jiaozhou Bay. Our results demonstrat that photobleaching, temperature and the origin of CDOM strongly affected the efficiency of CO photoproduction. The concentration, absorbance and fluorescence of CDOM exponentially decreased with increasing light dose. Terrestrial riverine organic matter could be more prone to photodegradation than the marine algae-derived one. The relationships between CO AQY and the dissolved organic carbon-specific absorption coefficient at 254 nm for the photobleaching study were nonlinear, whereas those of the original samples were strongly linear. This suggests that: 1) terrestrial riverine CDOM was more efficient than marine algae-derived CDOM for CO photoproduction; 2) aromatic and olefinic moieties of the CDOM pool were affected more strongly by degradation processes than by aliphatic ones. Water temperature and the origin of CDOM strongly affected the efficiency of CO photoproduction. The photoproduction rate of CO in autumn was estimated to be 31.98 μmol m-2 d-1 and the total DOC photomineralization was equivalent to 3.25%-6.35% of primary production in Jiaozhou Bay. Our results indicate that CO photochemistry in coastal areas is important for oceanic carbon cycle.

  10. Conversion of carbon monoxide intensities tomolecular hydrogen abundances

    Kutner, M.L.; Leung, C.M.

    1985-01-01

    We present results of theoretical models (static spherical clouds with a microturbulent velocity field) to study the conversion of carbon monoxide (CO) line parameters into molecular hydrogen (H 2 ) column densities, N2. The three potential H 2 tracers that we investigate are the integrated 12 CO and 13 CO intensities, I 12 and I 13 , and the 13 CO LTE column density, N( 13 . We find that I 12 may be a reasonable tracer of N2 under conditions appropriate to the envelopes of giant molecular clouds and for studies involving cloud ensembles of different cloud sizes and velocity dispersions. However, it saturates under higher density conditions. It is important that empirical conversion factors be set using the types of objects to which they will be applied. For this reason, our analysis suggests that the conversion factor N2/I 12 for giant molecular clouds in the molecular ring of our galaxy may be a factor of 2 lower than the average used by many observers. This lower value is supported by some recent empirical determinations. The quantity I 13 is a good tracer of N2 over a wide range of densities but it is more sensitive to the actual 13 CO abundance. The quantity N( 13 is similar to I 13 as a good tracer of N2 except at low densities and temperatures. The ratio I 12 /I 13 may be used to delineate temperature and column density effects. Finally, we find a strong temperature dependence in the various conversion factors, with N2/I 12 scaling with gas temperature (T/sub k/ approximately as (T/sub k/)/sup -1.3/

  11. Titanium monoxide spectroscopy following laser-induced optical breakdown

    Parigger, Christian G.; Woods, Alexander C.; Keszler, Anna; Nemes, László; Hornkohl, James O.

    2012-01-01

    This work investigates Titanium Monoxide (TiO) in ablation-plasma by employing laser-induced breakdown spectroscopy (LIBS) with 1 to 10 TW/cm 2 irradiance, pulsed, 13 nanosecond, Q-switched Nd:YAG laser radiation at the fundamental wavelength of 1064 nm. The analysis of TiO is based on our first accurate determination of transition line strengths for selected TiO A-X, B-X, and E-X transitions, particularly TiO A-X γ and B-X γ′ bands. Electric dipole line strengths for the A 3 Φ-X 3 δ and B 3 Π-X 3 δ bands of TiO are computed. The molecular TiO spectra are observed subsequent to laser-induced breakdown (LIB). We discuss analysis of diatomic molecular spectra that may occur simultaneously with spectra originating from atomic species. Gated detection is applied to investigate the development in time of the emission spectra following LIB. Collected emission spectra allow one to infer micro-plasma parameters such as temperature and electron density. Insight into the state of the micro-plasma is gained by comparing measurements with predictions of atomic and molecular spectra. Nonlinear fitting of recorded and computed diatomic spectra provides the basis for molecular diagnostics, while atomic species may overlap and are simultaneously identified. Molecular diagnostic approaches similar to TiO have been performed for diatomic molecules such as AlO, C 2 , CN, CH, N 2 , NH, NO and OH.

  12. Magnetic Resonance Imaging Findings in Chronic Carbon Monoxide Intoxication

    Durak, A. C.; Coskun, A.; Yikilmaz, A.; Erdogan, F.; Mavili, E.; Guven, M. [Hospital of Erciyes Univ., Kayseri (Turkey). Dept. of Radiology

    2005-05-01

    Purpose: To define the cranial magnetic resonance imaging (MRI) features of the chronic stage of carbon monoxide (CO) poisoning in patients with and without neuropsychiatric sequelae. Material and Methods: Eight patients who had neither symptoms nor neurological sequelae and eight patients with neuropsychiatric sequelae were included in the study. Patients aged between 9 to 57 (mean 32.2 years). All patients had been comatose at initial admittance and awoke after normobaric 100% oxygen therapy within 1-7 days. In this study, the patients were being examined with routine cranial MRI between 1 and 10 years (mean 3.4 years) after exposure to CO. Results: The most common finding was bilateral symmetric hyperintensity of the white matter, which was more significant in the centrum semiovale, with relative sparing of the temporal lobes and anterior parts of the frontal lobes on T2-weighted and FLAIR images in all patients. Cerebral cortical atrophy was seen in 10 patients; mild atrophy of cerebellar hemispheres in 8; and vermian atrophy in 11. Corpus callosum was atrophic in one patient. Bilateral globus pallidus lesions were seen in three patients. The lesions were hypointense on T1-weighted images and hyperintense on T2-weighted and FLAIR images. Conclusion: Patients with severe CO intoxication may develop persistent cerebral changes independently of their neuropsychiatric findings in the chronic stage. They may present with characteristic MRI findings as described here, even if asymptomatic. The history of CO exposure is therefore helpful for recognizing and interpreting the MRI findings of chronic stage CO intoxication.

  13. Mitochondria recycle nitrite back to the bioregulator nitric monoxide

    Nohl, H.; Staniek, K.; Sobhian, B.; Bahrami, S.; Redl, H.; Kozlov, A.V.

    2000-01-01

    Nitric monoxide (NO) exerts a great variety of physiological functions. L-Arginine supplies amino groups which are transformed to NO in various NO-synthase-active isoenzyme complexes. NO-synthesis is stimulated under various conditions increasing the tissue of stable NO-metabolites. The major oxidation product found is nitrite. Elevated nitrite levels were reported to exist in a variety of diseases including HIV, reperfusion injury and hypovolemic shock. Denitrifying bacteria such as Paracoccus denitrificans have a membrane bound set of cytochromes (cyt cd 1 , cyt bc) which were shown to be involved in nitrite reduction activities. Mammalian mitochondria have similar cytochromes which form part of the respiratory chain. Like in bacteria quinols are used as reductants of these types of cytochromes. The observation of one-e - divergence from this redox-couple to external dioxygen made us to study whether this site of the respiratory chain may also recycle nitrite back to its bioactive form NO. Thus, the aim of the present study was therefore to confirm the existence of a reductive pathway which reestablishes the existence of the bioregulator NO from its main metabolite NO 2 - . Our results show that respiring mitochondria readily reduce added nitrite to NO which was made visible by nitrosylation of deoxyhemoglobin. The adduct gives characteristic triplet-ESR-signals. Using inhibitors of the respiratory chain for chemical sequestration of respiratory segments we were able to identify the site where nitrite is reduced. The results confirm the ubiquinone/cyt bc 1 couple as the reductant site where nitrite is recycled. The high affinity of NO to the heme-iron of cytochrome oxidase will result in an impairment of mitochondrial energy-production. ''Nitrite tolerance'' of angina pectoris patients using NO-donors may be explained in that way. (author)

  14. Erythropoietin in the treatment of carbon monoxide neurotoxicity in rat.

    Moallem, Seyed Adel; Mohamadpour, Amir Hooshang; Abnous, Khalil; Sankian, Mojtaba; Sadeghnia, Hamid Reza; Tsatsakis, Aristidis; Shahsavand, Shabnam

    2015-12-01

    Erythropoietin (EPO) plays a critical role in the development of the nervous system. In this study, the effects of EPO in carbon monoxide (CO) neurotoxicity were examined. Rats were exposed to 3000 ppm CO for 1 h and then different doses of EPO were administrated intraperitoneally. After 24 h, glial fibrillary acidic protein (GFAP) levels in the serum were determined and water content of brain and the extravasation of a tracer (Evans blue) were measured. Brain lipid peroxidation, myeloperoxidase activity Myelin basic protein (MBP) and BAX/BcL2 protein relative expressions were determined. Cation exchange chromatography was used to evaluate MBP alterations. Seven days after exposure, pathological assessment was performed after Klüver-Barrera staining. EPO reduced malondialdehyde levels at all doses (2500, 5000 and 10,000 u/kg). Lower doses of EPO (625, 1250, 2500 u/kg) significantly decreased the elevated serum levels of GFAP. EPO could not reduce the water content of the edematous poisoned brains. However, at 5000 and 10,000 u/kg it protected the blood brain barrier against integrity loss as a result of CO. EPO could significantly decrease the MPO activity. CO-mediated oxidative stress caused chemical alterations in MBP and EPO could partially prevent these biochemical changes. Fewer vacuoles and demyelinated fibers were found in the EPO-treated animals. EPO (5000 u/kg) could restore the MBP density. CO increased brain BAX/Bcl-2 ratio 38.78%. EPO reduced it 38.86%. These results reveal that EPO could relatively prevent different pathways of neurotoxicity by CO poisoning and thus has the potential to be used as a novel approach to manage this poisoning. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Carbon Monoxide in Meat and Fish Packaging: Advantages and Limits

    Roncalés, Pedro

    2018-01-01

    Due to increased demands for greater expectation in relation to quality, convenience, safety and extended shelf-life, combined with growing demand from retailers for cost-effective extensions of fresh muscle foods’ shelf-life, the food packaging industry quickly developed to meet these expectations. During the last few decades, modified atmosphere packaging (MAP) of foods has been a promising area of research, but much remains to be known regarding the use of unconventional gases such carbon monoxide (CO). The use of CO for meat and seafood packaging is not allowed in most countries due to the potential toxic effect, and its use is controversial in some countries. The commercial application of CO in food packaging was not then considered feasible because of possible environmental hazards for workers. CO has previously been reported to mask muscle foods’ spoilage, and this was the primary concern raised for the prohibition, as this may mislead consumers. This review was undertaken to present the most comprehensive and current overview of the widely-available, scattered information about the use of CO in the preservation of muscle foods. The advantages of CO and its industrial limits are presented and discussed. The most recent literature on the consumer safety issues related to the use of CO and consumer acceptance of CO especially in meat packaging systems were also discussed. Recommendations and future prospects were addressed for food industries, consumers and regulators on what would be a “best practice” in the use of CO in food packaging. All this promotes high ethical standards in commercial communications by means of effective regulation, for the benefit of consumers and businesses in the world, and this implies that industrialized countries and members of their regulatory agencies must develop a coherent and robust systems of regulation and control that can respond effectively to new challenges. PMID:29360803

  16. Unusual way of suicide by carbon monoxide. Case Report.

    Zelený, Michal; Pivnička, Jan; Šindler, Martin; Kukleta, Pavel

    2015-01-01

    Authors discuss the case of a suicide of a 29-year-old man caused by carbon monoxide (CO) intoxication. What the authors found interesting was the unusual way of committing suicide that required good technical skills and expert knowledge. The level of carboxyhemoglobin (COHb) in the blood of the deceased man was routinely determined by the modified method by Blackmoore (1970), using gas chromatography/thermal conductivity detection. The level of saturation of the hemoglobin by CO in the collected blood sample is determined relatively to the same sample saturated to 100%. In the blood sample of the deceased man the lethal concentration of COHb of 76.5% was determined. Within the following examinations the blood alcohol concentration of 0.05 g.kg(-1) was determined. Further analysis revealed traces of sertraline, its metabolite N-desmethylsertraline, omeprazole and caffeine in the liver tissue, traces of N-desmethylsertraline, ibuprofen and caffeine in urine sample, and only traces of caffeine in the stomach content and blood samples were proved. To commit suicide the man used a sophisticated double container-system equipped with a timer for controlled generation of CO based on the chemical reaction of concentrated sulphuric acid and formic acid. The used timer was set by an electromechanical timer switch that triggered the fatal reaction of the acids while the man was sleeping. The authors discuss an unusual case of suicide by CO intoxication rarely seen in the area of forensic medicine and toxicology that is specific due to its sophisticated way of execution.

  17. CROSS-CORRELATIONS AS A COSMOLOGICAL CARBON MONOXIDE DETECTOR

    Pullen, Anthony R.; Doré, Olivier; Chang, Tzu-Ching; Lidz, Adam

    2013-01-01

    We present a new procedure to measure the large-scale carbon monoxide (CO) emissions across cosmic history. As a tracer of large-scale structure (LSS), the CO gas content as a function of redshift can be quantified by its three-dimensional fluctuation power spectra. Furthermore, cross-correlating CO emission with other LSS tracers offers a way to measure the emission as a function of scale and redshift. Here we introduce the model relevant for such a cross-correlation measurement between CO and other LSS tracers, and between different CO rotational lines. We propose a novel use of cosmic microwave background (CMB) data and attempt to extract redshifted CO emissions embedded in the Wilkinson Microwave Anisotropy Probe (WMAP) data set. We cross-correlate the all-sky WMAP7 data with LSS data sets, namely, the photometric quasar sample and the luminous red galaxy sample from the Sloan Digital Sky Survey Data Releases 6 and 7, respectively. We are unable to detect a cross-correlation signal with either CO(1-0) or CO(2-1) lines, mainly due to the instrumental noise in the WMAP data. However, we are able to rule out models more than three times greater than our more optimistic model. We discuss the cross-correlation signal from the thermal Sunyaev-Zeldovich effect and dust as potential contaminants, and quantify their impact for our CO measurements. We discuss forecasts for current CMB experiments and a hypothetical future CO-focused experiment, and propose to cross-correlate CO temperature data with the Hobby-Eberly Telescope Dark Energy Experiment Lyα-emitter sample, for which a signal-to-noise ratio of 58 is possible.

  18. Carbon monoxide inhalation increases microparticles causing vascular and CNS dysfunction

    Xu, Jiajun; Yang, Ming [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Kosterin, Paul [Department of Neuroscience, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Salzberg, Brian M. [Department of Physiology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Milovanova, Tatyana N.; Bhopale, Veena M. [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States); Thom, Stephen R., E-mail: sthom@smail.umaryland.edu [Department of Emergency Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA 19104 (United States)

    2013-12-01

    We hypothesized that circulating microparticles (MPs) play a role in pro-inflammatory effects associated with carbon monoxide (CO) inhalation. Mice exposed for 1 h to 100 ppm CO or more exhibit increases in circulating MPs derived from a variety of vascular cells as well as neutrophil activation. Tissue injury was quantified as 2000 kDa dextran leakage from vessels and as neutrophil sequestration in the brain and skeletal muscle; and central nervous system nerve dysfunction was documented as broadening of the neurohypophysial action potential (AP). Indices of injury occurred following exposures to 1000 ppm for 1 h or to 1000 ppm for 40 min followed by 3000 ppm for 20 min. MPs were implicated in causing injuries because infusing the surfactant MP lytic agent, polyethylene glycol telomere B (PEGtB) abrogated elevations in MPs, vascular leak, neutrophil sequestration and AP prolongation. These manifestations of tissue injury also did not occur in mice lacking myeloperoxidase. Vascular leakage and AP prolongation were produced in naïve mice infused with MPs that had been obtained from CO poisoned mice, but this did not occur with MPs obtained from control mice. We conclude that CO poisoning triggers elevations of MPs that activate neutrophils which subsequently cause tissue injuries. - Highlights: • Circulating microparticles (MPs) increase in mice exposed to 100 ppm CO or more. • MPs are lysed by infusing the surfactant polyethylene glycol telomere B. • CO-induced MPs cause neutrophil activation, vascular leak and CNS dysfunction. • Similar tissue injuries do not arise with MPs obtained from air-exposed, control mice.

  19. Selective carbon monoxide oxidation over Ag-based composite oxides

    Guldur, C. [Gazi University, Ankara (Turkey). Chemical Engineering Department; Balikci, F. [Gazi University, Ankara (Turkey). Institute of Science and Technology, Environmental Science Department

    2002-02-01

    We report our results of the synthesis of 1 : 1 molar ratio of the silver cobalt and silver manganese composite oxide catalysts to remove carbon monoxide from hydrogen-rich fuels by the catalytic oxidation reaction. Catalysts were synthesized by the co-precipitation method. XRD, BET, TGA, catalytic activity and catalyst deactivation studies were used to identify active catalysts. Both CO oxidation and selective CO oxidation were carried out in a microreactor using a reaction gas mixture of 1 vol% CO in air and another gas mixture was prepared by mixing 1 vol% CO, 2 vol% O{sub 2}, 84 vol% H{sub 2}, the balance being He. 15 vol% CO{sub 2} was added to the reactant gas mixture in order to determine the effect of CO{sub 2}, reaction gases were passed through the humidifier to determine the effect of the water vapor on the oxidation reaction. It was demonstrated that metal oxide base was decomposed to the metallic phase and surface areas of the catalysts were decreased when the calcination temperature increased from 200{sup o}C to 500{sup o}C. Ag/Co composite oxide catalyst calcined at 200{sup o}C gave good activity at low temperatures and 90% of CO conversion at 180{sup o}C was obtained for the selective CO oxidation reaction. The addition of the impurities (CO{sub 2} or H{sub 2}O) decreased the activity of catalyst for selective CO oxidation in order to get highly rich hydrogen fuels. (author)

  20. Exhaled carbon monoxide in asthmatics: a meta-analysis

    Huang Mao

    2010-04-01

    Full Text Available Abstract Background The non-invasive assessment of airway inflammation is potentially advantageous in asthma management. Exhaled carbon monoxide (eCO measurement is cheap and has been proposed to reflect airway inflammation and oxidative stress but current data are conflicting. The purpose of this meta-analysis is to determine whether eCO is elevated in asthmatics, is regulated by steroid treatment and reflects disease severity and control. Methods A systematic search for English language articles published between 1997 and 2009 was performed using Medline, Embase and Cochrane databases. Observational studies comparing eCO in non-smoking asthmatics and healthy subjects or asthmatics before and after steroid treatment were included. Data were independently extracted by two investigators and analyzed to generate weighted mean differences using either a fixed or random effects meta-analysis depending upon the degree of heterogeneity. Results 18 studies were included in the meta-analysis. The eCO level was significantly higher in asthmatics as compared to healthy subjects and in intermittent asthma as compared to persistent asthma. However, eCO could not distinguish between steroid-treated asthmatics and steroid-free patients nor separate controlled and partly-controlled asthma from uncontrolled asthma in cross-sectional studies. In contrast, eCO was significantly reduced following a course of corticosteroid treatment. Conclusions eCO is elevated in asthmatics but levels only partially reflect disease severity and control. eCO might be a potentially useful non-invasive biomarker of airway inflammation and oxidative stress in nonsmoking asthmatics.

  1. Carbon Monoxide in Meat and Fish Packaging: Advantages and Limits

    Djamel Djenane

    2018-01-01

    Full Text Available Due to increased demands for greater expectation in relation to quality, convenience, safety and extended shelf-life, combined with growing demand from retailers for cost-effective extensions of fresh muscle foods’ shelf-life, the food packaging industry quickly developed to meet these expectations. During the last few decades, modified atmosphere packaging (MAP of foods has been a promising area of research, but much remains to be known regarding the use of unconventional gases such carbon monoxide (CO. The use of CO for meat and seafood packaging is not allowed in most countries due to the potential toxic effect, and its use is controversial in some countries. The commercial application of CO in food packaging was not then considered feasible because of possible environmental hazards for workers. CO has previously been reported to mask muscle foods’ spoilage, and this was the primary concern raised for the prohibition, as this may mislead consumers. This review was undertaken to present the most comprehensive and current overview of the widely-available, scattered information about the use of CO in the preservation of muscle foods. The advantages of CO and its industrial limits are presented and discussed. The most recent literature on the consumer safety issues related to the use of CO and consumer acceptance of CO especially in meat packaging systems were also discussed. Recommendations and future prospects were addressed for food industries, consumers and regulators on what would be a “best practice” in the use of CO in food packaging. All this promotes high ethical standards in commercial communications by means of effective regulation, for the benefit of consumers and businesses in the world, and this implies that industrialized countries and members of their regulatory agencies must develop a coherent and robust systems of regulation and control that can respond effectively to new challenges.

  2. Evaluation of exposure to carbon monoxide associated with passive smoking

    Jo, W.-K.; Oh, J.-W.; Dong, J.-I.

    2004-01-01

    The current study measured breath carbon monoxide (CO) concentrations prior to and at prescribed time intervals after exposure to passive smoking under controlled conditions, along with the air CO concentration in the exposure room during the exposure periods. The postexposure breath CO levels were 1.4-2.7 times higher than the background breath CO levels after 30 min of exposure, yet only slightly higher after 10 min of exposure, thereby confirming that exposure to CO from passive smoking causes a significant body burden of CO. The air CO concentration gradually increased during the burning of a cigarette(s), regardless of the exposure duration, whereas it slightly decreased after burning. However, the pattern of breath CO decay was similar for the two different types of exposure (during and after a cigarette(s)) in each subject. The decrease in the postexposure alveolar CO concentrations was slow even in the early phase of the decay curves, indicating a monocompartment uptake and elimination model for the human body. The half-lives (78-277 min) estimated in the present study were comparable to those reported in previous studies associated with CO exposure from active smoking or other activities. The current study also evaluated the CO exposure of visitors and workers at three different types of recreation facility (bars, Internet cafes, and billiard halls) typically associated with passive smoking. The results confirmed that passive smoking is the major contributor to the CO exposure of nonsmoking visitors in a recreation environment. In addition, workplace exposure to CO from passive smoking was found to be the most important contributor to the daily CO exposure of nonsmoking recreation workers

  3. Computed Tomographic Findings of Acute Carbon Monoxide Posioning

    Park, Young Keun; Won, Hee Sun; Lee, Seung Ro; Hahm, Chang Kok

    1983-01-01

    Carbon monoxide (CO) is a kind of frequent toxic gas around our living lives, for common use of briquets as fuel, and its pathologic effect has been known due to mainly hypoxia and direct cytotoxicity in some part to almost all organs, especially to the brain and heart. Some authors have reported pathologic and anatomic changes of the acute of poisoning, although in a few cases, that bilaterally symmetrical lesions of the globs pallidus or cerebral white matter regarded as typical. After using computed tomography (CT), those findings have been discovered more easily and accurately. Authors analysed CT findings of 32 cases, who had a history of acute CO poisoning and performed CT at Hanyang University Hospital from May 1970 to June 1983. The results were as follows: 1. Of all 32 cases with CT scan, low density lesions were demonstrated in 28 cases (88%) and others were hemorrhage and calcified in 2(6%), respectively. 2. All lesions were seen as bilaterally symmetrical, except 2 cases of hemorrhage and 1 of low density. 3. Of all 28 cases of the low densities, 15 cases(53.6%) were located in the globs pallidus, 10(35.7%) in the cerebral white matter and 3(10.7%) in both of them. 4. Of all 113 cases of the low density lesions in the cerebral white matter, common locations were in the frontal and parietal lobes (65.6%), and more in frontal (40.6%). 5. Of all 113 cases of low density lesions in the cerebral white matter, cases of involving all of the lobes were found in only 4. 6. All of 2 cases of the calcified lesions were seen at both sides of the globs pallidus, symmetrically. 7. All of 2 cases of the hemorrhage were seen at thalamus, ventricles and head of caudate nucleus, and these locations were different from those of the low densities or calcifications.

  4. Environmental tobacco smoke exposure among non-smoking waiters: measurement of expired carbon monoxide levels

    Ronaldo Laranjeira

    2000-07-01

    Full Text Available CONTEXT: Exposure to environmental tobacco smoke is a health risk that is of concern to patrons and of particular concern to employees of restaurants and bars. OBJECTIVE: To assess environmental tobacco smoke exposure (using expired carbon monoxide levels in non-smoking waiters before and after a normal day's shift and to compare pre-exposure levels with non-smoking medical students. DESIGN: An observational study. SETTING: Restaurants with more than 50 tables or 100 places in São Paulo. SUBJECTS: 100 non-smoking restaurant waiters and 100 non-smoking medical students in São Paulo, Brazil. MAIN MEASUREMENTS: Levels of expired carbon monoxide, measured with a Smokerlyser (Bedfont EC 50 Scientific, before and after a normal day's work. RESULTS: Waiters' pre-exposure expired carbon monoxide levels were similar to those of medical students, but after a mean of 9 hours exposure in the workplace, median levels more than doubled (2.0 ppm vs. 5.0 ppm, P <0.001. Post-exposure carbon monoxide levels were correlated with the number of tables available for smokers (Kendall's tau = 0.2, P <0.0001. CONCLUSIONS: Exposure to environmental tobacco smoke is the most likely explanation for the increase in carbon monoxide levels among these non-smoking waiters. These findings can be used to inform the ongoing public health debate on passive smoking.

  5. [Protective effects of endogenous carbon monoxide against myocardial ischemia-reperfusion injury in rats].

    Zhou, Zhen; Ma, Shuang; Liu, Jie; Ji, Qiao-Rong; Cao, Cheng-Zhu; Li, Xiao-Na; Tang, Feng; Zhang, Wei

    2018-04-25

    The present study is aimed to explore the effects of endogenous carbon monoxide on the ischemia-reperfusion in rats. Wistar rats were intraperitoneally injected with protoporphyrin cobalt chloride (CoPP, an endogenous carbon monoxide agonist, 5 mg/kg), zinc protoporphyrin (ZnPP, an endogenous carbon monoxide inhibitor, 5 mg/kg) or saline. Twenty-four hours after injection, the myocardial ischemia-reperfusion model was made by Langendorff isolated cardiac perfusion system, and cardiac function parameters were collected. Myocardial cGMP content was measured by ELISA, and the endogenous carbon monoxide in plasma and myocardial enzymes in perfusate at 10 min after reperfusion were measured by colorimetry. The results showed that before ischemia the cardiac functions of CoPP, ZnPP and control groups were stable, and there were no significant differences. After reperfusion, cardiac functions had significant differences among the three groups (P endogenous carbon monoxide can maintain cardiac function, shorten the time of cardiac function recovery, and play a protective role in cardiac ischemia-reperfusion.

  6. Vapor Pressure and Evaporation Coefficient of Silicon Monoxide over a Mixture of Silicon and Silica

    Ferguson, Frank T.; Nuth, Joseph A., III

    2012-01-01

    The evaporation coefficient and equilibrium vapor pressure of silicon monoxide over a mixture of silicon and vitreous silica have been studied over the temperature range (1433 to 1608) K. The evaporation coefficient for this temperature range was (0.007 plus or minus 0.002) and is approximately an order of magnitude lower than the evaporation coefficient over amorphous silicon monoxide powder and in general agreement with previous measurements of this quantity. The enthalpy of reaction at 298.15 K for this reaction was calculated via second and third law analyses as (355 plus or minus 25) kJ per mol and (363.6 plus or minus 4.1) kJ per mol respectively. In comparison with previous work with the evaporation of amorphous silicon monoxide powder as well as other experimental measurements of the vapor pressure of silicon monoxide gas over mixtures of silicon and silica, these systems all tend to give similar equilibrium vapor pressures when the evaporation coefficient is correctly taken into account. This provides further evidence that amorphous silicon monoxide is an intimate mixture of small domains of silicon and silica and not strictly a true compound.

  7. The Effect of Carbon Monoxide Poisoning on Platelet Volume in Children

    Halise Akça

    2017-04-01

    Full Text Available Introduction: Carbon monoxide poisoning is one of the most important causes of morbidity and mortality. There is increasing evidence supporting the important role of mean platelet volume (MPV as a marker of hypoxia and inflammation. In this study, we aimed to determine changes in MPV values in pediatric patients with carbon monoxide poisoning. Methods: We retrospectively evaluated children who were diagnosed with carbon monoxide poisoning in our hospital between January 2005 and 2014. Results: We included 228 children with carbon monoxide poisoning (49% male in this retrospective, controlled study. The mean age of the patients was 88±56 months. Control group consisted of 200 age-matched healthy children. There was no statistically significant difference in MPV levels between the study and control groups (8.43±1.1 fL and 8.26±0.7 fL, respectively. No correlation of MPV and platelet count with carboxyhemoglobin (COHb was found. Conclusion: In our study, it was determined that MPV value was not a helpful parameter for predicting the diagnosis of acute carbon monoxide poisoning in childhood. The difference between the MPV values and the lack of significance and the absence of correlation between MPV value and COHb level led to the fact that MPV was not a guide indicating the clinical severity of the condition.

  8. Correlation of computed tomography, magnetic resonance imaging and clinical outcome in acute carbon monoxide poisoning.

    Ozcan, Namik; Ozcam, Giray; Kosar, Pinar; Ozcan, Ayse; Basar, Hulya; Kaymak, Cetin

    2016-01-01

    Carbon monoxide is a toxic gas for humans and is still a silent killer in both developed and developing countries. The aim of this case series was to evaluate early radiological images as a predictor of subsequent neuropsychological sequelae, following carbon monoxide poisoning. After carbon monoxide exposure, early computed tomography scans and magnetic resonance imaging findings of a 52-year-old woman showed bilateral lesions in the globus pallidus. This patient was discharged and followed for 90 days. The patient recovered without any neurological sequela. In a 58-year-old woman exposed to carbon monoxide, computed tomography showed lesions in bilateral globus pallidus and periventricular white matter. Early magnetic resonance imaging revealed changes similar to that like in early tomography images. The patient recovered and was discharged from hospital. On the 27th day of exposure, the patient developed disorientation and memory impairment. Late magnetic resonance imaging showed diffuse hyperintensity in the cerebral white matter. White matter lesions which progress to demyelination and end up in neuropsychological sequelae cannot always be diagnosed by early computed tomography and magnetic resonance imaging in carbon monoxide poisoning. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  9. Details management in the application of percutaneous nephroscope holmium laser lithotripsy%细节管理在经皮肾镜钬激光碎石术中的应用研究

    王地萍; 张红芹

    2014-01-01

    目的:观察细节管理在经皮肾镜钬激光碎石术中的应用效果。方法:通过对56例患者进行经皮肾镜钬激光碎石的手术配合和对其围手术期的护理,总结出手术各个环节的护理要点。结果:56例手术患者中,一例中转切开取石,其余55例均碎石成功,效果非常满意,无并发症发生。结论:经皮肾镜钬激光碎石术具有出血少,创伤小,痛苦少,住院时间短、病人恢复快等优点,做好护理细节管理是保证手术顺利完成的重要条件。%Objective:To observe the details of the management in the application of percutaneous nephroscope holmium laser lithotripsy. Methods:By means of 56 patients with percutaneous nephroscope holmium laser lithotrip-sy procedure and the perioperative nursing, sums up the operation nursing key points of each part. Results:56 pa-tients with surgery, in case of transit the stones cut, the remaining 55 cases of gravel, effect is very satisfactory, no complications occurred. Conclusion: Percutaneous nephroscope holmium laser lithotripsy with less bleeding, small trauma, less pain, shorter hospitalization time and patients recover fast, do a good job in nursing detail management is vital to ensure that operation is completed.

  10. A population-based exposure assessment methodology for carbon monoxide: Development of a carbon monoxide passive sampler and occupational dosimeter

    Apte, Michael G. [Univ. of California, Berkeley, CA (United States)

    1997-09-01

    Two devices, an occupational carbon monoxide (CO) dosimeter (LOCD), and an indoor air quality (IAQ) passive sampler were developed for use in population-based CO exposure assessment studies. CO exposure is a serious public health problem in the U.S., causing both morbidity and mortality (lifetime mortality risk approximately 10{sup -4}). Sparse data from population-based CO exposure assessments indicate that approximately 10% of the U.S. population is exposed to CO above the national ambient air quality standard. No CO exposure measurement technology is presently available for affordable population-based CO exposure assessment studies. The LOCD and IAQ Passive Sampler were tested in the laboratory and field. The palladium-molybdenum based CO sensor was designed into a compact diffusion tube sampler that can be worn. Time-weighted-average (TWA) CO exposure of the device is quantified by a simple spectrophotometric measurement. The LOCD and IAQ Passive Sampler were tested over an exposure range of 40 to 700 ppm-hours and 200 to 4200 ppm-hours, respectively. Both devices were capable of measuring precisely (relative standard deviation <20%), with low bias (<10%). The LOCD was screened for interferences by temperature, humidity, and organic and inorganic gases. Temperature effects were small in the range of 10°C to 30°C. Humidity effects were low between 20% and 90% RH. Ethylene (200 ppm) caused a positive interference and nitric oxide (50 ppm) caused a negative response without the presence of CO but not with CO.

  11. Solubility of carbon monoxide in bio-oil compounds

    Qureshi, Muhammad Saad; Le Nedelec, Tom; Guerrero-Amaya, Hernando; Uusi-Kyyny, Petri; Richon, Dominique; Alopaeus, Ville

    2017-01-01

    Highlights: • CO solubility was measured in four bio-oil compounds using static-analytic VLE equipment. • A comparison on the performance of different EoS (PC-SAFT, SRK and PR) was made. • Modelling of polar compounds with Polar PC-SAFT was tested. • Polar PC-SAFT is not needed for weakly polar compounds (μ < 1.0 D). - Abstract: The solubility of carbon monoxide is measured in four different bio-oil compounds (furan, diacetyl, 2-methylfuran, and trans-crotonaldehyde) at temperatures (273.15, 283.15, 298.15, and 323.15 K) and pressures up to 8 MPa using a static-analytical VLE measurement method. The equipment was validated by measuring the solubility of CO 2 in methanol at 298.15 K and pressures (P = 2.9–5.7 MPa). The results were compared with the abundantly available literature values. PC-SAFT, Polar PC-SAFT (PPC-SAFT), and Cubic (SRK, PR) EoS, part of commercial process simulator Aspen Plus V. 8.6, are used here for modelling purpose. The pure component parameters needed for PC-SAFT and PPC-SAFT EoS models, are regressed using the experimental liquid density and vapour pressure data of the pure components. It was observed that furan, 2-methylfuran and diacetyl, having weak dipole moments (μ < 1.0 D), could be modelled reasonably well without the addition of polar contribution using conventional PC-SAFT, while it is recommended to use PPC-SAFT for the description of a polar compound like trans-crotonaldehyde (μ ∼ 3.67 D). It was observed that SRK and PR EoS have similar predictive ability in comparison to PC-SAFT for a mixture of CO with weakly polar compounds in this study. A comparison between the performances of EoS models was made in two ways: first by setting the binary interaction parameter k ij to zero, and second by adjusting a temperature-dependent binary interaction parameter (k ij ). All the models perform with comparable accuracy with adjusted binary interaction parameters. However, due to the large differences between the chemical and

  12. Neurological Effects of Acute Carbon Monoxide Poisoning in Children

    Coskun YARAR

    2009-11-01

    Full Text Available Carbon monoxide poisoning (COP is one of the most common causes of mortality and morbidity due to poisoning in all over the world. Although the incidence of COP has not been known exactly in the childhood, almost one-third of CO exposures occurred in children. The data regarding COP in children are inconclusive. Children may be more vulnerable to CO exposure than adults as a result of their high respiration and metabolic rates, high oxygen metabolism, and immature central nervous system. Recent researches proposed new theories about neurological effects of CO toxicity. The clinical presentations associated acute COP may be various and nonspecific. Unrecognized CO exposure may lead to significant morbidity and mortality. CO exposed children often become symptomatic earlier, and recover more rapidly, than similarly CO exposed adults. Mild clinical signs and symptoms associated with COP are headache, dizziness, weakness, lethargy, and myalgia; however, severe signs and symptoms such as blurred vision, syncope, convulsion, coma, cardiopulmonary arrest and death can also accompany with COP. Neurologic manifestations can include altered mental status at different degrees, neck stiffness, tremor, ataxia, and positive Babinski's sign. Delayed neurologic sequels (DNS of COP might be seen in children like adults. DNS symptoms and signs in children include memory problems, mental retardation, mutism, fecal and urinary incontinence, motor deficits, facial palsy, psychosis, chronic headache, seizures, and epilepsy. After CO exposure children must be cared to detect and treat DNS. Although hyperbaric oxygen therapy (HBOT is reported to prevent development of DNS, its indications, application duration and procedures are controversial in both of the children and adults. Although their predictive values are limited, exposing to CO more than eight hours and suffering from CO-induced coma, cardiac arrest, lactic acidosis, high COHb levels, and pathologic findings

  13. Absorption of nicotine and carbon monoxide from passive smoking under natural conditions of exposure.

    Jarvis, M J; Russell, M A; Feyerabend, C

    1983-01-01

    Seven non-smokers were exposed to tobacco smoke under natural conditions for two hours in a public house. Measures of nicotine and cotinine in plasma, saliva, and urine and expired air carbon monoxide all showed reliable increases. The concentrations of carbon monoxide and nicotine after exposure averaged 15.7% and 7.5% respectively of the values found in heavy smokers. Although the increase in expired air carbon monoxide of 5.9 ppm was similar to increases in smokers after a single cigarette, the amount of nicotine absorbed was between a tenth and a third of the amount taken in from one cigarette. Since this represented a relatively extreme acute natural exposure, any health risks of passive smoking probably depend less on quantitative factors than on qualitative differences between sidestream and mainstream smoke. PMID:6648864

  14. [Carboxyhemoglobin concentration in carbon monoxide poisoning. Critical appraisal of the predictive value].

    Köthe, L; Radke, J

    2010-06-01

    In cases of unclear depression of conciousness, arrhythmia and symptoms of cardiac insufficiency inadvertent carbon monoxide intoxication should always be taken into consideration. Rapid diagnosis of acute carbon monoxide intoxication with mostly unspecific symptoms requires an immediate supply of high dose oxygen which enables a distinct reduction of mortality and long-term morbidity. Levels of carboxyhemoglobin, however, should not be used as a parameter to decide whether to supply normobaric or the more efficient hyperbaric oxygen. There is no sufficient coherence between carboxyhemoglobin blood levels and clinical symptoms. Increased carboxyhemoglobin concentrations help to diagnose acute carbon monoxide intoxication but do not allow conclusions to be drawn about possible long-term neuropsychiatric or cardiac consequences.

  15. Occupational carbon monoxide poisoning in the State of Washington, 1994-1999.

    Lofgren, Don J

    2002-04-01

    Carbon monoxide poisonings continue to be significant and preventable for a number of work operations. This study assesses occupational carbon monoxide morbidity and mortality for the state of Washington based on a review of workers' compensation records for the years 1994-1999. The study characterizes sources, industries, and causative factors, and further attempts to identify work operations most at risk. Records were identified by both injury source and diagnostic codes. The study limits itself to non-fire-related carbon monoxide poisonings and primarily those from acute exposure. A decline in the number of claims was not evident, but the number of incidents per year showed a slight decline. Carbon monoxide poisonings were found to occur throughout all types of industries. The greatest number of claims was found in agriculture, followed by construction and wholesale trade, with these three accounting for more than half the claims and nearly half of the incidents. The more severe poisonings did not necessarily occur in industries with the greatest number of incidents. The major source for carbon monoxide poisoning was forklift trucks, followed by auto/truck/bus, portable saws, and more than 20 other sources. Fruit packing and storage had the highest number of incidents mostly due to fuel-powered forklift activity, with nearly half of the incidents occurring in cold rooms. Adverse health effects as measured by carboxyhemoglobin, hyperbaric oxygen treatment, unconsciousness, and number and cost of claims were indexed by source. Though several specific work operations were identified, the episodic nature of carbon monoxide poisonings, as well as the diverse industries and sources, and the opportunity for a severe poisoning in any number of operations, poses challenges for effective intervention.

  16. Assessment of exposure to carbon monoxide group of firefighters from fire fighting and rescue units

    Jadwiga Lembas-Bogaczyk

    2011-03-01

    Full Text Available Firemen threat during fire burning of chemical substances indicated presence of carbon monoxide (CO in all cases. Carbon monoxide causes death of fire. Inhaled through respiratory system, links with hemoglobin, thus blocking transport and distribution of oxygen in the body. This leads to tissue anoxia, which is a direct threat to firefighters’ life. The purpose of this study was to assess the exposure to carbon monoxide of participating firefighters extinguishing fire. Estimation of carbon monoxide quantity absorbed by firefighters was isolated in a group of 40 firefighters from Fire Extinguishing and Rescue Unit of State Fire in Nysa. The study was conducted by measuring carbon monoxide in exhaled air. For measurement of carbon monoxide concentration in exhaled air Micro CO meter was used. Results were demonstrated separately for nonsmokers (n425 and smokers (n415. Mean COHb[%] levels in nonsmokers, measured prior the rescue action was 0,3950,3% and increased statistically significant after the action to 0,6150,34%, while in the group smokers, this level was 2,1750,64% before the action and increased insignificantly after the action to 2,3350,63%. The average COHb level in the same groups before and after exercise, was respectively: for nonsmokers prior to exercise was 0,4850,28% and after exercise decreased statistically significant to 0,3050,27%. In the group of smokers before exercise was 2,2350,61% and decreased statistically significant up to 1,5450,71%. It was no difference between the group of age and time of employment.

  17. Muusikamaailm : Suvefestivalid täies hoos / Priit Kuusk

    Kuusk, Priit, 1938-

    2001-01-01

    Suvefestivalidest : Aix-en-Provence'i festivalist, Londoni "Promenaadikontsertidest", Spoleto "Kahe maailma festivalist", Sapporo "Pacific Music Festival'ist", Bregenzi festivalist, New Yorgi Lincoln Center'i festivalist ja Verbieri festivalist

  18. Giuliani jälle hoos / Maria-Kristiina Soomre

    Soomre, Maria-Kristiina, 1978-

    2001-01-01

    Brooklyni muuseum plaanib avada näituse "Kujutisele pühendunud: kaasaegsed mustad fotograafid", kus on väljas ka Renee Coxi foto "Yo Mama's Last Supper", mis kujutab Kristust alasti musta naisena. Foto on põhjustanud linnapea R. Giuliani pahameele, linnavalitsus plaanib muuseumi rendilepingu lõpetamist või eelarve kärpimist.

  19. Occupational carbon monoxide violations in the State of Washington, 1994-1999.

    Lofgren, Don J

    2002-07-01

    Occupational exposure to carbon monoxide continues to cause a number of injuries and deaths. This study reviewed the State of Washington OSHA inspection records for occupational safety or health violations related to carbon monoxide for the time period 1994-1999 to assess the agency's efforts and further identify and characterize causative factors. Inspection data were also compared with carbon monoxide claims data from a companion study to determine if the agency was visiting the most at risk work operations. Inspections were identified by searching computerized violation texts for "carbon monoxide" or "CO." The study found 142 inspections with one or more carbon monoxide violations. Inspections were spread over 84 different 4-digit Standard Industrial Classification codes. Most inspections were initiated as a result of a complaint or other informant. Inspections were predominantly in construction and manufacturing, whereas carbon monoxide claims were mores evenly distributed between the major industries. Inspections also may have failed to find violations for some types of equipment responsible for carbon monoxide claims. Forklifts were the source of carbon monoxide most often associated with a violation, followed by compressors for respirators, auto/truck/bus, and temporary heating devices. Inspections in response to poisonings found common factors associated with lack of recognition and failure to use or maintain equipment and ventilation. Some work sites with one or more poisonings were not being inspected. Only 10 of the 51 incidents with industrial insurance claim reports of carboxyhemoglobin at or above 20 percent were inspected. Further, it was found more preventive efforts should be targeted at cold storage operations and certain warehouse and construction activities. It is proposed that more specific standards, both consensus and regulatory, would provide additional risk reduction. Reliance upon safe work practices as a primary method of control in the

  20. Accidental carbon monoxide poisoning during yagya for faith healing--a case report.

    Behera, C; Millo, T M; Jaiswal, A; Dogra, T D

    2013-03-01

    A 20-year-old female and a 45-year-old male were found lying dead on the floor with frothand vomitus stain present over mouth, nose and face in a closed room. An earthen bowl with incomplete burnt woods, flowers, food materials, agarbati, etc, was also found lying near the body of the two deceased. The cause of death, established by autopsy and toxicological examination was carbon monoxide poisoning in both victims. The source of carbon monoxide was incomplete burnt woods used for yagya during puja (a faith healing practice) for bearing children.

  1. Cyclic process for producing methane from carbon monoxide with heat removal

    Frost, Albert C.; Yang, Chang-lee

    1982-01-01

    Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.

  2. The Range of 1-3 keV Electrons in Solid Oxygen and Carbon Monoxide

    Oehlenschlæger, M.; Andersen, H.H.; Schou, Jørgen

    1985-01-01

    The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than that in n......The range of 1-3 keV electrons in films of solid oxygen and carbon monoxide has been measured by a mirror substrate method. The technique used here is identical to the one previously used for range measurements in solid hydrogen and nitrogen. The range in oxygen is slightly shorter than...

  3. 40 CFR Table 5 to Subpart Jjj of... - Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units 5 Table 5 to Subpart JJJ of Part 62 Protection of... of Part 62—Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units...

  4. 40 CFR Table 2 to Subpart Aaaa of... - Carbon Monoxide Emission Limits for New Small Municipal Waste Combustion Units

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Carbon Monoxide Emission Limits for New... Pt. 60, Subpt. AAAA, Table 2 Table 2 to Subpart AAAA of Part 60—Carbon Monoxide Emission Limits for.... Compliance is determined by continuous emission monitoring systems. b Block averages, arithmetic mean. See...

  5. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas

    Makoto Onodera

    2016-01-01

    Full Text Available Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p=0.021, but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  6. Utility of the Measurement of Carboxyhemoglobin Level at the Site of Acute Carbon Monoxide Poisoning in Rural Areas.

    Onodera, Makoto; Fujino, Yasuhisa; Kikuchi, Satoshi; Sato, Masayuki; Mori, Kiyofumi; Beppu, Takaaki; Inoue, Yoshihiro

    2016-01-01

    Objective. This study examined the hypothesis that correlations exist between the carbon monoxide exposure time and the carboxyhemoglobin concentration at the site of carbon monoxide poisoning, using a pulse carbon monoxide oximeter in rural areas or the carboxyhemoglobin concentration measured at a given medical institution. Background. In previous studies, no definitive relationships between the arterial blood carboxyhemoglobin level and the severity of carbon monoxide poisoning have been observed. Method. The subjects included patients treated for acute carbon monoxide poisoning in whom a medical emergency team was able to measure the carboxyhemoglobin level at the site of poisoning. We examined the relationship between the carboxyhemoglobin level at the site of poisoning and carbon monoxide exposure time and the relationships between the arterial blood carboxyhemoglobin level and carbon monoxide exposure time. Results. A total of 10 patients met the above criteria. The carboxyhemoglobin levels at the site of poisoning were significantly and positively correlated with the exposure time (rs = 0.710, p = 0.021), but the arterial blood carboxyhemoglobin levels were not correlated with the exposure time. Conclusion. In rural areas, the carboxyhemoglobin level measured at the site of carbon monoxide poisoning correlated with the exposure time.

  7. Efficacy of holmium laser enucleation of the prostate (HoLEP) in men with bladder outlet obstruction (BOO) and non-neurogenic bladder dysfunction.

    Pyun, Jong Hyun; Kang, Sung Gu; Kang, Seok Ho; Cheon, Jun; Kim, Je Jong; Lee, Jeong Gu

    2017-09-01

    We aimed to compare the short-term outcomes of men who had urodynamic evidence of detrusor underactivity (DU) or detrusor overactivity (DO) of a non-neurogenic etiology as well as bladder outlet obstruction (BOO) and who underwent Holmium Laser Enucleation of the prostate (HoLEP). A database of 322 patients who underwent HoLEP between 2010 and 2014 was analyzed. Patients were classified into three groups according to the results of a preoperative urodynamic study. Preoperative parameters such as International Prostate Symptom Score (IPSS), Quality of Life (QoL) index, IPSS grade, uroflowmetry were compared with postoperative parameters measured at 6 months. There were 138 patients with BOO-only and 89 patients with BOO and detrusor dysfunction including 56 with DO and 33 with DU. The degree of improvement in IPSS-total (BOO: 10.7, DO: 8.3, DU: 7.0; p = 0.023) was greater in the BOO-only group than in the DU group. There were more patients whose IPSS grade improved in the BOO-only group (71%) than in the detrusor dysfunction group (DO: 53.6% and DU: 45.5%). Postoperative IPSS-voiding (4.5 vs 7.0), and Qmax (18 vs 13.7) in the BOO-only group were significantly better than those in the DU group. Additionally, postoperative IPSS-storage (4.7 vs 6.7), and IPSS-total (9.1 vs 12.3) in the BOO-only group were significantly better than in the DO group (all p < 0.05). In conclusion, early surgical management for men with severe LUTS and associated BPH before secondary degeneration occurs may be beneficial for preserving detrusor function and yield better treatment outcomes. Copyright © 2017. Published by Elsevier Taiwan.

  8. Nonspecific genitourinary pain improves after prostatectomy using holmium laser enucleation of prostate in patients with benign prostatic hyperplasia: a prospective study.

    Sung Han Kim

    Full Text Available OBJECTIVE: To investigate changes in nonspecific genitourinary discomfort or pain (GUDP before and after holmium laser enucleation of prostate (HoLEP. GUDP associated with lower urinary tract symptoms (LUTS is a common complaint among benign prostatic hyperplasia (BPH patients, but very little is known about this clinical entity. METHODS: From February 2010 to August 2011, 100 HoLEP patients with complete clinical data at a single institution were enrolled in the study to analyze the degree of GUDP with a visual analog scale (VAS from 0 to 10 points at baseline and at 3 and 6 months postoperatively, and to investigate any relationships between GUDP and urodynamics, uroflowmetry, and scores from the International Prostate Symptom Score (IPSS questionnaire. RESULTS: Fifty-six patients had LUTS only, while the remaining 44 had both LUTS and GUDP. Pain was located in the suprapubic (42.0%, perineal/penile (33.0%, back (17.0%, and perianal (8.0% regions. During the post-operative period, at six months, the VAS, IPSS, peak flow rate and post-void residual volume had improved significantly in 44 GUDP patients (p<0.010. GUDP had completely resolved in 40 (90.9% patients and had decreased in four (9.1% patients, while seven (12.5% patients developed GUDP with voiding in the urethral and perineal areas by the third month postoperatively. When compared to patients with complete resolution, those with persistent GUDP were found to have a significantly higher preoperative presence of bladder outlet obstruction (BOO as an independent risk factor (OR 6.173, 95% CI 1.132-1.323. CONCLUSION: Both GUDP and LUTS improved significantly after HoLEP. Patients with significant preoperative BOO tended to have persistent GUDP after surgery.

  9. Do We Really Need to Wear Proper Eye Protection When Using Holmium:YAG Laser During Endourologic Procedures? Results from an Ex Vivo Animal Model on Pig Eyes.

    Villa, Luca; Cloutier, Jonathan; Compérat, Eva; Kronemberg, Peter; Charlotte, Frederic; Berthe, Laurent; Rouchausse, Yann; Salonia, Andrea; Montorsi, Francesco; Traxer, Olivier

    2016-03-01

    We sought to evaluate the effect of holmium:yttrium-aluminum-garnet (Ho:YAG) laser exposure on ex vivo pig eyes and to test the protective action of different glasses in preventing eye lesions in case of accident. We pointed the tip of a Ho:YAG laser fiber from different distances (0, 3, 5, 8, 10, and 20 cm, respectively) toward the center of the pupil of the pig eye. The Ho:YAG laser was activated for 1 or 5 seconds at three different settings (0.5 J-20 Hz, 1 J-10 Hz, and 2 J-10 Hz, respectively). The experiment was repeated using laser safety glasses and eyeglasses. A total of 78 pig eyes were used. The effects of the Ho:YAG laser on pig eyes were assessed by histopathology. Comparable laser emission experiments were performed on thermal paper at different distances using different pulse energies. Ho:YAG laser-induced corneal lesions were observed in unprotected eyes, ranging from superficial burning lesions to full-thickness necrotic areas, and were directly related to pulse energy and time of exposure and inversely related to the distance from the eye. When the laser was placed 5 cm or more, no corneal damage was observed regardless of the laser setting and the time of exposure. Similar distance/energy level relationships were observed on thermal paper. No damage was observed to the lens or the retina in any of the Ho-YAG laser-treated eyes or in any of the eyes protected by laser safety and eyeglasses. Ho:YAG lasers can cause damage when set to high energy, but only to the cornea, from close distances (0-5 cm) and in the absence of eye protection. Eyeglasses are equally effective in preventing laser damage as laser safety glasses.

  10. Comparison of Predictive Factors for Postoperative Incontinence of Holmium Laser Enucleation of the Prostate by the Surgeons' Experience During Learning Curve.

    Shigemura, Katsumi; Tanaka, Kazushi; Yamamichi, Fukashi; Chiba, Koji; Fujisawa, Masato

    2016-03-01

    To detect predictive factors for postoperative incontinence following holmium laser enucleation of the prostate (HoLEP) according to surgeon experience (beginner or experienced) and preoperative clinical data. Of 224 patients, a total of 203 with available data on incontinence were investigated. The potential predictive factors for post-HoLEP incontinence included clinical factors, such as patient age, and preoperative urodynamic study results, including detrusor overactivity (DO). We also classified the surgeons performing the procedure according to their HoLEP experience: beginner (predictive factor at the super-short period (the next day of catheter removal: odds ratio [OR], 3.375; P=0.000). Additionally, patient age, surgeon mentorship (inverse correlation), and prostate volume were significant predictive factors at the 1-month interval after HoLEP (OR, 1.072; P=0.004; OR, 0.251; P=0.002; and OR, 1.008; P=0.049, respectively). With regards to surgeon experience, DO and preoperative International Prostate Symptom Score (inverse) at the super-short period, and patient age and mentorship (inverse correlation) at the 1-month interval after HoLEP (OR, 3.952; P=0.002; OR, 1.084; P=0.015; and OR,1.084; P=0.015; OR, 0.358; P=0.003, respectively) were significant predictive factors for beginners, and first desire to void (FDV) at 1 month after HoLEP (OR, 1.009; P=0.012) was a significant predictive factor for experienced surgeons in multivariate analysis. Preoperative DO, IPSS, patient age, and surgeon mentorship were significant predictive factors of postoperative patient incontinence for beginner surgeons, while FDV was a significant predictive factors for experienced surgeons. These findings should be taken into account by surgeons performing HoLEP to maximize the patient's quality of life with regards to urinary continence.

  11. Holmium:YAG Laser Ablation for the Management of Lower Urinary Tract Foreign Bodies Following Incontinence Surgery: A Case Series and Systematic Review.

    Chan, Garson; Mamut, Adiel; Martin, Paul; Welk, Blayne

    2016-11-01

    The objective of this study was to determine the outcomes associated with the endoscopic removal of foreign bodies (such as mesh or permanent suture) in the lower urinary tract after female stress incontinence surgery with the Holmium:YAG (Ho:YAG) laser, and to systematically review the literature on this topic. A retrospective chart review of 18 consecutive women found to have mesh or suture exposure was performed. All patients underwent Ho:YAG laser ablation. A systematic review was performed to identify literature addressing the endoscopic management of mesh/suture exposure after stress incontinence surgery. Between November 2011 and February 2016, 18 women underwent Ho:YAG laser ablation of exposed mesh or suture. Presenting symptoms included lower urinary tract symptoms, pelvic pain, incontinence, or recurrent urinary tract infections. Thirteen women had a previous synthetic midurethral sling and five had a prior retropubic suspension. The median age was 58 years (interquartile range [IQR] 50-60) and median follow-up was 2 years (IQR 1-2). Four patients (22%) had residual mesh after the first procedure, requiring a repeat endoscopic procedure. Only one patient had a small amount of asymptomatic residual mesh on cystoscopy after the final procedure. Only minor postoperative complications were observed. Eight patients had stress incontinence and four underwent operative treatment for this. In our systematic review, we identified 16 case series, which described a total of 158 patients. Women most commonly presented with voiding symptoms or incontinence. Based on the synthesis of these data, repeat procedures were necessary in 16% and vesicovaginal fistula occurred in 2%. Recurrent/persistent stress incontinence was present in 20%, and of these patients, 3/4 underwent a new stress incontinence procedure. Both our case series and the systematic review of the literature demonstrated that endoscopic treatment of lower urinary tract foreign bodies after stress

  12. Efficacy and Safety of Semirigid Ureteroscopy Combined with Holmium: YAG Laser in the Treatment of Upper Urinary Tract Calculi: Is it a Good Alternative Treatment Option of Flexible Ureteroscopy for Developing Countries

    Bibi, S.; Siddiqui, T. R.; Ahmed, W.; Alam, S. E.; Shah, S. A.; Soomro, I. A.; Qureshi, S.

    2015-01-01

    Objective: To assess the success rates of endoscopic management of upper ureteral stones using semirigid ureterorenoscopy and holmium: YAG laser lithotripters. Method: A total of 74 patients with an established diagnosis of upper ureteric stone and scheduled for endoscopic ureteral stone treatment were retrospectively evaluated. Failure was defined as the inability to contact or fragment the stone, migration of the stone into the renal pelvis and difficulty in visualizing the stone for the second time. Success rates and influencing factors as for stone-free state were investigated. Results: Mean age of our patients was 45.99±15.00 (range: 24-82) years. In 14 of 74 patients procedural failure was observed. Double J stents were implanted in 65 percent of the patients and ureteral catheterization was performed on 20 percent of them. The total success rate was 81.1 percent. Major complication rate was 1.1 percent. Factors effecting the success rate as gender, age, body mass index, grade of hydronephrosis and stone size were evaluated and only age was found to be statistically significant. Conclusion: Despite some potential risks, semirigid ureterorenoscopic stone extraction and holmium: YAG laser lithotripters are still safe and effective treatment alternatives for management of upper ureteral stones. (author)

  13. Stable isotope composition of atmospheric carbon monoxide. A modelling study

    Gromov, Sergey S.

    2014-01-01

    This study aims at an improved understanding of the stable carbon and oxygen isotope composition of the carbon monoxide (CO) in the global atmosphere by means of numerical simulations. At first, a new kinetic chemistry tagging technique for the most complete parameterisation of isotope effects has been introduced into the Modular Earth Submodel System (MESSy) framework. Incorporated into the ECHAM/MESSy Atmospheric Chemistry (EMAC) general circulation model, an explicit treatment of the isotope effects on the global scale is now possible. The expanded model system has been applied to simulate the chemical system containing up to five isotopologues of all carbon- and oxygen-bearing species, which ultimately determine the δ 13 C, δ 18 O and Δ 17 O isotopic signatures of atmospheric CO. As model input, a new stable isotope-inclusive emission inventory for the relevant trace gases has been compiled. The uncertainties of the emission estimates and of the resulting simulated mixing and isotope ratios have been analysed. The simulated CO mixing and stable isotope ratios have been compared to in-situ measurements from ground-based observatories and from the civil-aircraft-mounted CARIBIC-1 measurement platform. The systematically underestimated 13 CO/ 12 CO ratios of earlier, simplified modelling studies can now be partly explained. The EMAC simulations do not support the inferences of those studies, which suggest for CO a reduced input of the highly depleted in 13 C methane oxidation source. In particular, a high average yield of 0.94 CO per reacted methane (CH 4 ) molecule is simulated in the troposphere, to a large extent due to the competition between the deposition and convective transport processes affecting the CH 4 to CO reaction chain intermediates. None of the other factors, assumed or disregarded in previous studies, however hypothesised to have the potential in enriching tropospheric CO in 13 C, were found significant when explicitly simulated. The

  14. Integrated Science Assessment (ISA) for Carbon Monoxide (Second External Review Draft, Sep 2009)

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of t...

  15. Catalytic Reduction of Nitrous Oxide with Carbon Monoxide over Calcined Co–Mn–Al Hydrotalcite

    Pacultová, K.; Obalová, L.; Kovanda, F.; Jirátová, Květa

    2008-01-01

    Roč. 137, 2-4 (2008), s. 358-389 ISSN 0920-5861 R&D Projects: GA ČR(CZ) GA106/05/0366 Institutional research plan: CEZ:AV0Z40720504 Keywords : nitrous oxide * carbon monoxide * mixed oxide catalysts Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.004, year: 2008

  16. Multimodel simulations of carbon monoxide: Comparison with observations and projected near-future changes

    Shindell, D.T.; Faluvegi, G.; Stevenson, D.S.; Krol, M.C.; Emmons, L.K.; Lamarque, J.F.; Petron, G.; Dentener, F.J.; Ellingsen, K.; Schultz, M.G.; Wild, O.; Amann, M.; Atherton, C.S.; Bergmann, D.J.; Bey, I.; Butler, T.; Cofala, J.; Collins, W.J.; Derwent, R.G.; Doherty, R.M.; Drevet, J.; Eskes, H.J.; Fiore, A.M.; Gauss, M.; Hauglustaine, D.A.; Horowitz, L.W.; Isaksen, I.S.A.; Lawrence, M.G.; Montanaro, V.; Muller, J.F.; Pitari, G.; Prather, M.J.; Pyle, J.A.; Rast, S.; Rodriguez, J.M.; Sanderson, M.G.; Savage, N.H.; Strahan, S.E.; Sudo, K.; Szopa, S.; Unger, N.; Noije, van T.P.C.; Zeng, G.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-of-the-art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  17. SEASONAL SOIL FLUXES OF CARBON MONOXIDE IN BURNED AND UNBURNED BRAZILIAN SAVANNAS

    Soil-atmosphere fluxes of carbon monoxide (CO) were measured from September 1999 through November 2000 in savanna areas in central Brazil (Cerrado) under different fire regimes using transparent and opaque static chambers. Studies focused on two vegetation types, cerrado stricto...

  18. Chemical production from waste carbon monoxide: its potential for energy conservation

    Rohrmann, C.A.; Schiefelbein, G.F.; Molton, P.M.; Li, C.T.; Elliott, D.C.; Baker, E.G.

    1977-11-01

    Results of a study of the potential for energy conservation by producing chemicals from by-product or waste carbon monoxide (CO) from industrial sources are summarized. Extensive compilations of both industrial sources and uses for carbon monoxide were developed and included. Reviews of carbon monoxide purification and concentration technology and preliminary economic evaluations of carbon monoxide concentration, pipeline transportation and utilization of CO in the synthesis of ammonia and methanol are included. Preliminary technical and economic feasibility studies were made of producing ammonia and methanol from the by-product CO produced by a typical elemental phosphorus plant. Methanol synthesis appears to be more attractive than ammonia synthesis when using CO feedstock because of reduced water gas shift and carbon dioxide removal requirements. The economic studies indicate that methanol synthesis from CO appears to be competitive with conventional technology when the price of natural gas exceeds $0.82/million Btu, while ammonia synthesis from CO is probably not competitive until the price of natural gas exceeds $1.90/million Btu. It is concluded that there appears to be considerable potential for energy conservation in the chemical industry, by collecting CO rather than flaring it, and using it to make major chemicals such as ammonia and methanol.

  19. MODELLING OF CARBON MONOXIDE AIR POLLUTION IN LARG CITIES BY EVALUETION OF SPECTRAL LANDSAT8 IMAGES

    M. Hamzelo

    2015-12-01

    Full Text Available Air pollution in large cities is one of the major problems that resolve and reduce it need multiple applications and environmental management. Of The main sources of this pollution is industrial activities, urban and transport that enter large amounts of contaminants into the air and reduces its quality. With Variety of pollutants and high volume manufacturing, local distribution of manufacturing centers, Testing and measuring emissions is difficult. Substances such as carbon monoxide, sulfur dioxide, and unburned hydrocarbons and lead compounds are substances that cause air pollution and carbon monoxide is most important. Today, data exchange systems, processing, analysis and modeling is of important pillars of management system and air quality control. In this study, using the spectral signature of carbon monoxide gas as the most efficient gas pollution LANDSAT8 images in order that have better spatial resolution than appropriate spectral bands and weather meters،SAM classification algorithm and Geographic Information System (GIS , spatial distribution of carbon monoxide gas in Tehran over a period of one year from the beginning of 2014 until the beginning of 2015 at 11 map have modeled and then to the model valuation ،created maps were compared with the map provided by the Tehran quality comparison air company. Compare involved plans did with the error matrix and results in 4 types of care; overall, producer, user and kappa coefficient was investigated. Results of average accuracy were about than 80%, which indicates the fit method and data used for modeling.

  20. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    Nasir, Ehson Fawad; Farooq, Aamir

    2018-01-01

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm

  1. Carbon monoxide oxidation using Zn-Cu-Ti hydrotalcite-derived ...

    Multioxide catalysts of zinc, copper and titanium with different ratios obtained from layered double hydroxide (LDH) precursors were used in the oxidation of carbon monoxide. The catalysts were characterized by energy-dispersive X-ray spectrometry, X-ray diffraction, thermal analyses (TG, DTG and DTA) and scanning ...

  2. Room-temperature cold-welding of gold nanoparticles for enhancing the electrooxidation of carbon monoxide.

    Liu, Cai; Li, Yong-Jun; Sun, Shi-Gang; Yeung, Edward S

    2011-04-21

    A cold-welding strategy is proposed to rapidly join together Au nanoparticles (AuNPs) into two-dimensional continuous structures for enhancing the electrooxidation of carbon monoxide by injecting a mixture of ethanol and tolulene into the bottom of a AuNP solution. © The Royal Society of Chemistry 2011

  3. Forensic aspects of carbon monoxide poisoning by charcoal burning in Denmark, 2008-2012

    Nielsen, Pia Rude; Gheorghe, Alexandra; Lynnerup, Niels

    2014-01-01

    Carbon monoxide (CO) inhalation is a well-known method of committing suicide. There has been a drastic increase in suicide by inhalation of CO, produced from burning charcoal, in some parts of Asia, and a few studies have reported an increased number of these deaths in Europe. CO-related deaths c...

  4. Evidence for long-range transport of carbon monoxide in the Southern Hemisphere from SCIAMACHY observations

    Gloudemans, A.M.S.; Krol, M.C.; Meirink, J.F.; de Laat, A.T.J.; van der Werf, G.R.; Schrijver, H.; van den Broek, M.M.P.; Aben, I.

    2006-01-01

    The SCIAMACHY satellite instrument shows enhanced carbon monoxide (CO) columns in the Southern Hemisphere during the local Spring. Chemistry-transport model simulations using the new GFEDv2 biomass-burning emission database show a similar temporal and spatial CO distribution, indicating that the

  5. An infrared spectroscopic study of the adsorption of carbon monoxide on silica-supported copper particles

    Jong, K.P. de; Geus, John W.; Joziasse, J.

    Infrared spectroscopy is used to study the adsorption of carbon monoxide (20°C; 0.1– 100 Torr) on copper-on-silica catalysts differently prepared and pretreated. As determined by electron microscopy and X-ray line broadening, the catalysts contain copper particles having sizes of 60 to 5000 Å

  6. 77 FR 8252 - Adequacy Status of the Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation...

    2012-02-14

    ... a SIP means that transportation activities will not produce new air quality violations, worsen... Anchorage, Alaska, Carbon Monoxide Maintenance Plan for Transportation Conformity Purposes AGENCY... Transportation & Public Facilities, and the U.S. Department of Transportation will be required to use [[Page 8253...

  7. Calculated Specific Volumes and Magnetic Moments of the 3d Transition Metal Monoxides

    Skriver, Hans Lomholt; Andersen, O. K.; Johansson, B.

    1980-01-01

    We have performed self-consistent, spin-polarized band structure calculations as a function of the lattice spacing for the 3d metal monoxides in order to obtain the equilibrium lattice constants. The calculated binding from the 3d electrons and the occurrence of antiferromagnetism account...

  8. A Retrospective Analysis of Pediatric Patients Admitted to the Pediatric Emergency Service for Carbon Monoxide Intoxication

    Metin Uysalol

    2011-09-01

    Full Text Available Objective: The aim of the study is to analyze the general aspects of cases with carbon monoxide intoxication in order to improve the approach to future patients. Material and Methods: The hospital records of 84 children (mean age 4.71±2.64 years; 48 male, 36 female who had been admitted to Paediatric Emergency Department for carbon monoxide intoxication between October 2007 and February 2009, were retrospectively evaluated in a descriptive analysis.Results: The source of carbon monoxide intoxication was heaters, waterheaters and fi re in 82.1%, 7.1% and 6% of cases, respectively. There was a statistically signifi cant difference between the carboxyhemoglobin levels of the patients according to the clinical classifi cation (p<0.05. The intoxication caused by heaters was observed signifi cantly in November, December and January (p<0.001, between 16:00-24:00 hours (p<0.001 and among more than one member of a family (p<0.001. A medium level correlation was detected between the treatment approach and clinical classifi cation (r=0.50, p<0.001. Conclusion: Carbon monoxide intoxication, in the presented series, was found to develop accidentally; mostly in the Winter season; during night hours when the family members gathered together. The carboxyhemoglobin levels were appropriate with the developing clinical findings. Carboxyhemoglobin level solely was not enough for achieving the diagnosis and planning the treatment.

  9. Carbon monoxide poisoning in Nigeria - it is time to pay attention ...

    Background: Carbon monoxide (CO) is a colourless, odourless gas and a cause of thousands of deaths across the world annually but its lethal consequences often go unrecognized, especially in developing countries. Aim: To discuss the subject of CO poisoning using local examples. Methods: Information was drawn from ...

  10. Multimodel simulations of carbon monoxide: comparison with observations and projected near-future changes

    Shindell, D.T.; Krol, M.C.

    2006-01-01

    We analyze present-day and future carbon monoxide (CO) simulations in 26 state-ofthe- art atmospheric chemistry models run to study future air quality and climate change. In comparison with near-global satellite observations from the MOPITT instrument and local surface measurements, the models show

  11. Hydrogen Oxidation on Gas Diffusion Electrodes for Phosphoric Acid Fuel Cells in the Presence of Carbon Monoxide and Oxygen

    Gang, Xiao; Li, Qingfeng; Hjuler, Hans Aage

    1995-01-01

    Hydrogen oxidation has been studied on a carbon-supported platinum gas diffusion electrode in a phosphoric acidelectrolyte in the presence of carbon monoxide and oxygen in the feed gas. The poisoning effect of carbon monoxide presentin the feed gas was measured in the temperature range from 80...... to 150°C. It was found that throughout the temperaturerange, the potential loss due to the CO poisoning can be reduced to a great extent by the injection of small amounts ofgaseous oxygen into the hydrogen gas containing carbon monoxide. By adding 5 volume percent (v/o) oxygen, an almost...

  12. Visual internal urethrotomy for management of urethral strictures in boys: a comparison of short-term outcome of holmium laser versus cold knife.

    Aboulela, Waseem; ElSheemy, Mohammed S; Shoukry, Mahmoud; Shouman, Ahmed M; Shoukry, Ahmed I; Ghoneima, Waleed; El Ghoneimy, Mohamed; Morsi, Hany A; Mohsen, Mostafa Abdel; Badawy, Hesham

    2018-04-01

    To compare efficacy and safety of visual internal urethrotomy (VIU) using holmium laser (Ho:YAG) (group A) versus cold knife (group B) in children with urethral strictures. It may be the first comparative study on this issue in children. This study compared Ho:YAG group, which was evaluated prospectively from January 2014 till January 2016, versus cold knife group, which was a historical control performed from March 2008 till February 2010. Children ≤ 13 years old with urethral strictures ≤ 1.5 cm were included successively. Recurrent cases, congenital obstructions and cases with complete arrest of dye in voiding cystourethrography were excluded. Scar tissue was incised at twelve o'clock. Outcome was compared using Student's t, Mann-Whitney, Chi-square or Fisher exact tests as appropriate. Each group included 21 patients. Mean age was 6.27 ± 3.23 (2-13) years old. Mean stricture length was 1.02 versus 1 cm in group A versus B, respectively (p = 0.862). Ten cases of penile/bulbous strictures and another 11 cases of membranous strictures were found in each group. There was no significant difference between both groups in preoperative data. Success rate for initial VIU was 66.7% in group A versus 38% in group B (p = 0.064). This was associated with significantly higher Q max in group A (mean 16.52 vs 12.09 ml/s; p = 0.03). Success rate after two trials of VIU was 76.2% for group A and 47.61% for group B (p = 0.057). No complications were reported in both groups. Laser VIU has a higher success rate than cold knife VIU for urethral strictures ≤ 1.5 cm in children with significantly higher Q max . Both are easy to perform, low invasive and safe.

  13. In Vitro Comparison of Holmium Lasers: Evidence for Shorter Fragmentation Time and Decreased Retropulsion Using a Modern Variable-pulse Laser.

    Bell, John Roger; Penniston, Kristina L; Nakada, Stephen Y

    2017-09-01

    To compare the performance of variable- and fixed-pulse lasers on stone phantoms in vitro. Seven-millimeter stone phantoms were made to simulate calcium oxalate monohydrate stones using BegoStone plus. The in vitro setting was created with a clear polyvinyl chloride tube. For each trial, a stone phantom was placed at the open end of the tubing. The Cook Rhapsody H-30 variable-pulse laser was tested on both long- and short-pulse settings and was compared to the Dornier H-20 fixed-pulse laser; 5 trials were conducted for each trial arm. Fragmentation was accomplished with the use of a flexible ureteroscope and a 273-micron holmium laser fiber using settings of 1 J × 12 Hz. The treatment time (in minute) for complete fragmentation was recorded as was the total retropulsion distance (in centimeter) during treatment. Laser fibers were standardized for all repetitions. The treatment time was significantly shorter with the H-30 vs the H-20 laser (14.3 ± 2.5 vs 33.1 ± 8.9 minutes, P = .008). There was no difference between the treatment times using the long vs short pulse widths of the H-30 laser (14.4 ± 3.4 vs 14.3 ± 1.7 minutes, P = .93). Retropulsion differed by laser type and pulse width, H-30 long pulse (15.8 ± 5.7 cm), H-30 short pulse (54.8 ± 7.1 cm), and H-20 (33.2 ± 12.5 cm) (P laser fragmented stone phantoms in half the time of the H-20 laser regardless of the pulse width. Retropulsion effects differed between the lasers, with the H-30 causing the least retropulsion. Longer pulse widths result in less stone retropulsion. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Comparison of Predictive Factors for Postoperative Incontinence of Holmium Laser Enucleation of the Prostate by the Surgeons’ Experience During Learning Curve

    Katsumi Shigemura

    2016-03-01

    Full Text Available Purpose: To detect predictive factors for postoperative incontinence following holmium laser enucleation of the prostate (HoLEP according to surgeon experience (beginner or experienced and preoperative clinical data. Methods: Of 224 patients, a total of 203 with available data on incontinence were investigated. The potential predictive factors for post-HoLEP incontinence included clinical factors, such as patient age, and preoperative urodynamic study results, including detrusor overactivity (DO. We also classified the surgeons performing the procedure according to their HoLEP experience: beginner (<21 cases and experienced (≥21 cases. Results: Our statistical data showed DO was a significant predictive factor at the super-short period (the next day of catheter removal: odds ratio [OR], 3.375; P=0.000. Additionally, patient age, surgeon mentorship (inverse correlation, and prostate volume were significant predictive factors at the 1-month interval after HoLEP (OR, 1.072; P=0.004; OR, 0.251; P=0.002; and OR, 1.008; P=0.049, respectively. With regards to surgeon experience, DO and preoperative International Prostate Symptom Score (inverse at the super-short period, and patient age and mentorship (inverse correlation at the 1-month interval after HoLEP (OR, 3.952; P=0.002; OR, 1.084; P=0.015; and OR,1.084; P=0.015; OR, 0.358; P=0.003, respectively were significant predictive factors for beginners, and first desire to void (FDV at 1 month after HoLEP (OR, 1.009; P=0.012 was a significant predictive factor for experienced surgeons in multivariate analysis. Conclusions: Preoperative DO, IPSS, patient age, and surgeon mentorship were significant predictive factors of postoperative patient incontinence for beginner surgeons, while FDV was a significant predictive factors for experienced surgeons. These findings should be taken into account by surgeons performing HoLEP to maximize the patient’s quality of life with regards to urinary continence.

  15. Holmium laser enucleation versus transurethral resection in patients with benign prostate hyperplasia: an updated systematic review with meta-analysis and trial sequential analysis.

    Sheng Li

    Full Text Available BACKGROUND: Holmium laser enucleation (HoLEP in surgical treatment of benign prostate hyperplasia (BPH potentially offers advantages over transurethral resection of the prostate (TURP. METHODS: Published randomized controlled trials (RCTs were identified from PubMed, EMBASE, Science Citation Index, and the Cochrane Library up to October 10, 2013 (updated on February 5, 2014. After methodological quality assessment and data extraction, meta-analysis was performed using STATA 12.0 and Trial Sequential Analysis (TSA 0.9 software. RESULTS: Fifteen studies including 8 RCTs involving 855 patients met the criteria. The results of meta-analysis showed that: a efficacy indicators: there was no significant difference in quality of life between the two groups (P>0.05, but compared with the TURP group, Qmax was better at 3 months and 12 months, PVR was less at 6, 12 months, and IPSS was lower at 12 months in the HoLEP, b safety indicators: compared with the TURP, HoLEP had less blood transfusion (RR 0.17, 95% CI 0.06 to 0.47, but there was no significant difference in early and late postoperative complications (P>0.05, and c perioperative indicators: HoLEP was associated with longer operation time (WMD 14.19 min, 95% CI 6.30 to 22.08 min, shorter catheterization time (WMD -19.97 h, 95% CI -24.24 to -15.70 h and hospital stay (WMD -25.25 h, 95% CI -29.81 to -20.68 h. CONCLUSIONS: In conventional meta-analyses, there is no clinically relevant difference in early and late postoperative complications between the two techniques, but HoLEP is preferable due to advantage in the curative effect, less blood transfusion rate, shorter catheterization duration time and hospital stay. However, trial sequential analysis does not allow us to draw any solid conclusion in overall clinical benefit comparison between the two approaches. Further large, well-designed, multicentre/international RCTs with long-term data and the comparison between the two approaches remain open.

  16. In vitro study of morphological and chemical modification threshold of bovine dental enamel irradiated by the holmium laser; Estudo in vitro das alteracoes morfologicas e quimicas do esmalte dental bovino irradiado pelo laser de holmio

    Eduardo, Patricia Lerro de Paula

    2001-07-01

    The aim of this study is to investigate the Ho:YLF laser effects on the dental enamel surface with regards to its morphology, thermal variations during its irradiation in the pulp chamber and its increased resistance to demineralization through quantitative analysis of calcium and phosphorous atoms reactive concentrations in samples. Twenty samples of bovine enamel were used and divided in four groups: control - acidulated phosphate fluoride (APF) application followed by demineralization treatment with lactic acid; irradiation with Ho:YLF laser (100 J/cm{sup 2}) followed by APF topic application and demineralization treatment with lactic acid; irradiation with Ho:YLF laser (350 J/cm{sup 2}) followed by APF topic application and demineralization treatment with lactic acid: and irradiation with Ho:YLF laser ( 450 J/cm{sup 2}) followed by APF topic application and demineralization treatment with lactic acid. Ali samples were quantified according to their calcium and phosphorous atoms relative concentrations before and after the treatments above. X-Ray fluorescence spectrochemical analysis and scanning electron microscopy were carried out. It was observed an increase on the calcium and phosphorous atoms concentration ratio and therefore the enamel demineralization reduction as a result of the lactic acid treatment in the samples irradiated with the holmium laser followed by the APF application. In order to evaluate the feasibility of this study for clinical purposes, morphological changes caused by the holmium laser irradiation were analyzed. Such modifications were characterized by melted and re-solidified regions of the enamel with consequent changes on its permeability and solubility. Temperature changes of ten human pre-molars teeth irradiated with 350 J/cm{sup 2} and 450 J/cm{sup 2} were also monitored in the pulp chamber in real time. Temperature increases over 4,20 C did not occur. The results obtained from this study along with the results from previous

  17. Acute Compartment Syndrome Which Causes Rhabdomyolysis by Carbon Monoxide Poisoning and Sciatic Nerve Injury Associated with It: A Case Report.

    Ji, Jung-Woo

    2017-09-01

    Rhabdomyolysis is most frequently caused by soft tissue injury with trauma to the extremities. Non-traumatic rhabdomyolysis may be caused by alcohol or drug abuse, infection, collagen disease, or intensive exercise, but incidence is low. In particular, rhabdomyolysis resulting from carbon monoxide poisoning is especially rare. If caught before death, carbon monoxide poisoning has been shown to cause severe muscle necrosis and severe muscle damage leading to acute renal failure. In cases of carbon-monoxide-induced rhabdomyolsis leading to acute compartment syndrome in the buttocks and sciatic nerve injury are rare. We have experience treating patients with acute compartment syndrome due to rhabdomyolysis following carbon monoxide poisoning. We report the characteristic features of muscle necrosis observed during a decompression operation and magnetic resonance imaging findings with a one-year follow-up in addition to a review of the literature.

  18. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 1 (SRL1) Carbon Monoxide Second by Second data

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  19. Measurement of Air Pollution from Satellites (MAPS) Space Radar Laboratory - 2 (SRL2) Carbon Monoxide Second by Second data

    National Aeronautics and Space Administration — MAPS Overview The MAPS experiment measures the global distribution of carbon monoxide (CO) mixing ratios in the free troposphere. Because of MAPS' previous flights...

  20. Toxicity of carbon monoxide hydrogen cyanide gas mixtures : exposure concentration, time to incapacitation, carboxyhemoglobin and blood cyanide parameters.

    1994-04-01

    During aircraft interior fires, carbon monoxide (CO) and hydrogen cyanide (HCN) are produced in sufficient amounts to cause incapacitation and death. Time-to-incapacitation (ti) is a practical parameter for estimating escape time in fire environments...

  1. Fetal brain damage following maternal carbon monoxide intoxication: an experimental study

    Ginsberg, M D; Myers, R E

    1974-01-01

    Techniques of fetal monitoring, including fetal blood sampling in utero, were employed to study the physiological effects of acute maternal carbon monoxide intoxication on nine term-pregnant female rhesus monkeys exposed to 0.1 to 0.3% inspired carbon monoxide over 1 to 3 hr. The mothers tolerated carboxyhemoglobin levels exceeding 60% without clinical sequelae, whereas the fetuses promptly developed profound hypoxia upon exposure of the mothers to CO. The fetal COHb levels rose only gradually over 1 to 3 hr, and thus contributed only slightly to the development of early fetal hypoxia. The fetal hypoxia was associated with bradycardia, hypotension, and metabolic and respiratory acidosis. Severity of intrauterine hypoxia was closely correlated with the appearance of brain damage. Brain swelling associated with hemorrhagic necrosis of the cerebral hemispheres (severe brain damage) appeared only in fetuses whose arterial oxygen content was reduced below 1.0 ml/100 ml for at least 45 min during the maternal CO intoxication.

  2. Vibrationally Excited Carbon Monoxide Produced via a Chemical Reaction Between Carbon Vapor and Oxygen

    Jans, Elijah R.; Eckert, Zakari; Frederickson, Kraig; Rich, Bill; Adamovich, Igor V.

    2017-06-01

    Measurements of the vibrational distribution function of carbon monoxide produced via a reaction between carbon vapor and molecular oxygen has shown a total population inversion on vibrational levels 4-7. Carbon vapor, produced using an arc discharge to sublimate graphite, is mixed with an argon oxygen flow. The excited carbon monoxide is vibrationally populated up to level v=14, at low temperatures, T=400-450 K, in a collision-dominated environment, 15-20 Torr, with total population inversions between v=4-7. The average vibrational energy per CO molecule formed by the reaction is 0.6-1.2 eV/molecule, which corresponds to 10-20% of the reaction enthalpy. Kinetic modeling of the flow reactor, including state specific vibrational processes, was performed to infer the vibrational distribution of the products of the reaction. The results show viability of developing of a new chemical CO laser from the reaction of carbon vapor and oxygen.

  3. Exposure to carbon monoxide, respirable suspended particulates, and volatile organic compounds while commuting by bicycle

    Bevan, M.A.J.; Proctor, C.J.; Baker-Rogers, J.; Warren, N.D.

    1991-01-01

    A portable air sampling system has been used to assess exposures to various substances while commuting by bicycle in an urban area. The major source of pollutants in this situation is motor vehicle exhaust emissions. Carbon monoxide, measured by electrochemical detection, was found at peak concentrations in excess of 62 ppm, with mean values over 16 individual 35-mm journeys being 10.5 ppm. Respirable suspended particulates, averaged over each journey period, were found at higher concentrations (mean 130 μg m -3 ) than would be expected in indoor situations. Mean exposure to benzene (at 56 μg m -3 ) and other aromatic volatile organic compounds was also relatively high. The influence of wind conditions on exposure was found to be significant. Commuting exposures to carbon monoxide, respirable suspended particulates, and aromatic VOCs were found to be higher than exposures in a busy high street and on common parkland

  4. Experimental study on surface wrinkling of silicon monoxide film on compliant substrate under thermally induced loads

    Li, Chuanwei; Kong, Yingxiao; Jiang, Wenchong; Wang, Zhiyong; Li, Linan; Wang, Shibin

    2017-06-01

    The wrinkling of a silicon monoxide thin film on a compliant poly(dimethylsiloxane) (PDMS) substrate structure was experimentally investigated in this study. The self-expansion effect of PDMS during film deposition was utilized to impose a pretensile strain on the structure through a specially made fixture. A laser scanning confocal microscope (LSCM) system with an in situ heating stage was employed for the real-time measurement. The Young’s modulus of the silicon monoxide thin film as well as the PDMS substrate was measured on the basis of the elasticity theory. Moreover, the effects of temperature variations on geometric parameters in the postbuckling state, such as wavelength and amplitude, were analyzed. It was proved that wavelength is relatively immune to thermal loads, while amplitude is much more sensitive.

  5. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  6. Unique case of fatal carbon monoxide poisoning in the absence of a combustible fossil fuel.

    Morgan, D R; Poon, P; Titley, J; Jagger, S F; Rutty, G N

    2001-09-01

    A 37-year-old man died as a result of exposure to carbon monoxide within an apartment. An investigation of the apartment showed no gas appliances or gas supply to the apartment and no evidence of any combustion event to any part of the apartment or roof space. Inhalation of dichloromethane was excluded. Heating to the apartment was found to be via an electrical storage heater, the examination of which revealed that the cast-iron core and insulating material showed evidence of heat damage with significant areas devoid of carbon. This electric storage heater is hypothesized to be the source of carbon for the fatal production of carbon monoxide within the apartment.

  7. Range measurements of keV hydrogen ions in solid oxygen and carbon monoxide

    Schou, J.; Soerensen, H.; Andersen, H.H.; Nielsen, M.; Rune, J.

    1984-01-01

    Ranges of 1.3-3.5 keV/atom hydrogen and deuterium molecular ions have been measured by a thin-film reflection method. The technique, used here for range measurements in solid oxygen and carbon monoxide targets, is identical to the one used previously for range measurements in hydrogen and nitrogen. The main aim was to look for phase-effects, i.e. gas-solid differences in the stopping processes. While measured ranges in solid oxygen were in agreement with known gas data, the ranges in solid carbon monoxide were up to 50% larger than those calculated from gas-stopping data. The latter result agrees with that previously found for solid nitrogen. (orig.)

  8. Theoretical studies on the catalytic oxidation of carbon monoxide on nickel clusters

    Srivastava, A.K.; Kojima, I.; Miyazaki, E.

    1986-01-01

    Complete neglect of differential overlap (CNDO) molecular orbital calculations using the method of Anno and Sakai for the evaluation of the valence orbital ionization potential (VOIP) were performed with the aim of studying the oxidation of carbon monoxide on nickel clusters. A cluster surface was assumed to be preadsorbed with oxygen and the variation of various bond energies with the approach of a carbon monoxide molecule was studied for different models. Various possibilities for the reaction path are discussed in the light of the theoretical findings and it is suggested that at a low coverage of oxygen the reaction may follow a Langmuir-Hinshelwood path, whereas at a high coverage, an Eley-Rideal path might be more probable. 55 references, 13 figures.

  9. Geostatistical modelling of carbon monoxide levels in Khartoum State (Sudan) - GIS pilot based study

    Alhuseen, A [Comenius University in Bratislava, Faculty of Natural Sciences, Dept. of Landscape Ecology, 84215 Bratislava (Slovakia); Madani, M [Ministry of Environment and Physical Development, 1111 Khartoum (Sudan)

    2012-04-25

    The objective of this study is to develop a digital GIS model; that can evaluate, predict and visualize carbon monoxide (CO) levels in Khartoum state. To achieve this aim, sample data had been collected, processed and managed to generate a dynamic GIS model of carbon monoxide levels in the study area. Parametric data collected from the field and analysis carried throughout this study show that (CO) emissions were lower than the allowable ambient air quality standards released by National Environment Protection Council (NEPC-USA) for 1998. However, this pilot study has found emissions of (CO) in Omdurman city were the highest. This pilot study shows that GIS and geostatistical modeling can be used as a powerful tool to produce maps of exposure. (authors)

  10. New Class of Hybrid Materials for Detection, Capture, and "On-Demand" Release of Carbon Monoxide.

    Pitto-Barry, Anaïs; Lupan, Alexandru; Ellingford, Christopher; Attia, Amr A A; Barry, Nicolas P E

    2018-04-25

    Carbon monoxide (CO) is both a substance hazardous to health and a side product of a number of industrial processes, such as methanol steam reforming and large-scale oxidation reactions. The separation of CO from nitrogen (N 2 ) in industrial processes is considered to be difficult because of the similarities of their electronic structures, sizes, and physicochemical properties (e.g., boiling points). Carbon monoxide is also a major poison in fuel cells because of its adsorption onto the active sites of the catalysts. It is therefore of the utmost economic importance to discover new materials that enable effective CO capture and release under mild conditions. However, methods to specifically absorb and easily release CO in the presence of contaminants, such as water, nitrogen, carbon dioxide, and oxygen, at ambient temperature are not available. Here, we report the simple and versatile fabrication of a new class of hybrid materials that allows capture and release of carbon monoxide under mild conditions. We found that carborane-containing metal complexes encapsulated in networks made of poly(dimethylsiloxane) react with CO, even when immersed in water, leading to dramatic color and infrared signature changes. Furthermore, we found that the CO can be easily released from the materials by simply dipping the networks into an organic solvent for less than 1 min, at ambient temperature and pressure, which not only offers a straightforward recycling method, but also a new method for the "on-demand" release of carbon monoxide. We illustrated the utilization of the on-demand release of CO from the networks by carrying out a carbonylation reaction on an electron-deficient metal complex that led to the formation of the CO-adduct, with concomitant recycling of the gel. We anticipate that our sponge-like materials and scalable methodology will open up new avenues for the storage, transport, and controlled release of CO, the silent killer and a major industrial poison.

  11. Influence of solvent on the infared spectrum of carbon monoxide adsorbed on platinum electrodes

    Feltovich, Susanne D.

    1993-01-01

    The behavior of adsorbed carbon monoxide on platinum was studied using potential difference infrared spectroscopy. Three solvents and three electrolytes were chosen, and data gathered at both high and low adsorbate coverages. The rate of change of IR peak position with applied potential, the Stark tuning rate, was used as an indicator of the local electric field strength at the interface. It was determined that neither solvated cation size nor bulk dielectric constant accoun...

  12. IR Laser Ablation of Silicon Monoxide in Gaseous Methanol and Hydrocarbons: Deposition of Polyoxocarbosilane

    Dřínek, Vladislav; Bastl, Zdeněk; Šubrt, Jan; Pola, Josef

    2004-01-01

    Roč. 71, č. 2 (2004), s. 431-444 ISSN 0165-2370 R&D Projects: GA ČR GA203/00/1288 Institutional research plan: CEZ:AV0Z4072921; CEZ:AV0Z4032918; CEZ:AV0Z4040901 Keywords : silicon monoxide * reactive laser ablation * polyoxocarbosilane coatings Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 1.352, year: 2004

  13. Carbon monoxide poisoning in children riding in the back of pickup trucks.

    Hampson, N B; Norkool, D M

    OBJECTIVE - To describe the case characteristics of a series of children poisoned with carbon monoxide while traveling in the back of pickup trucks. DESIGN - Pediatric cases referred for treatment of carbon monoxide poisoning with hyperbaric oxygen between 1986 and 1991 were reviewed. Those cases that occurred during travel in the back of pickup trucks were selected. Clinical follow-up by telephone interview ranged from 2 to 55 months. SETTING - A private, urban, tertiary care center in Seattle, Wash. PATIENTS - Twenty children ranging from 4 to 16 years of age. INTERVENTION - All patients were treated with hyperbaric oxygen. MAIN OUTCOME MEASURES - Characteristics of the poisoning incident and clinical patient outcome. RESULTS - Of 68 pediatric patients treated for accidental carbon monoxide poisoning, 20 cases occurred as children rode in the back of pickup trucks. In 17 of these, the children were riding under a rigid closed canopy on the rear of the truck, while three episodes occurred as children rode beneath a tarpaulin. Average carboxyhemoglobin level on emergency department presentation was 18.2% +/- 2.4% (mean +/- SEM; range, 1.6% to 37.0%). Loss of consciousness occurred in 15 of the 20 children. One child died of cerebral edema, one had permanent neurologic deficits, and 18 had no recognizable sequelae related to the episode. In all cases, the truck exhaust system had a previously known leak or a tail pipe that exited at the rear rather than at the side of the pickup truck. CONCLUSIONS - Carbon monoxide poisoning is a significant hazard for children who ride in the back of pickup trucks. If possible, this practice should be avoided.

  14. Intra-pulse Cavity Enhanced Measurements of Carbon Monoxide in a Rapid Compression Machine

    Nasir, Ehson Fawad

    2018-05-07

    A laser absorption sensor for carbon monoxide concentration was developed for combustion studies in a rapid compression machine using a pulsed quantum cascade laser near 4.89 μm. Cavity enhancement reduced minimum detection limit down to 2.4 ppm at combustion relevant conditions. Off-axis alignment and rapid intra-pulse down-chirp resulted in effective suppression of cavity noise.

  15. Relation of Hydrogen and Methane to Carbon Monoxide in Exhaust Gases from Internal-Combustion Engines

    Gerrish, Harold C; Tessmann, Arthur M

    1935-01-01

    The relation of hydrogen and methane to carbon monoxide in the exhaust gases from internal-combustion engines operating on standard-grade aviation gasoline, fighting-grade aviation gasoline, hydrogenated safety fuel, laboratory diesel fuel, and auto diesel fuel was determined by analysis of the exhaust gases. Two liquid-cooled single-cylinder spark-ignition, one 9-cylinder radial air-cooled spark-ignition, and two liquid-cooled single-cylinder compression-ignition engines were used.

  16. Multiple Victims of Carbon Monoxide Poisoning in the Aftermath of a Wildfire: A Case Series

    Luís Ramos dos Santos

    2018-03-01

    Conclusion: Use of hyperbaric oxygen appears to have reduced the incidence of the syndrome. This seems to be the first Portuguese series reporting use of hyperbaric oxygen in carbon monoxide poisoning due to wildfires. The authors intend to alert to the importance of referral of these patients because the indications and benefits of this treatment are well documented. This is especially important given the ever-growing issue of wildfires in Portugal.

  17. The indigenous Sea Gypsy divers of Thailand's west coast: measurement of carbon monoxide in the breathing air.

    Gold, D; Geater, A; Aiyarak, S; Juengpraert, W

    1999-07-01

    Approximately 400 indigenous divers live and work on Thailand's west coast. They dive with surface supplied air from primitive compressor units mounted on open boats which measure from seven to 11 meters in length. It was suspected that carbon monoxide was present in the breathing air of at least the gasoline-driven compressor units. To determine the presence of carbon monoxide gas in the breathing air, compressed air from the compressor was pumped through the diver air supply hose through a plenum (monitoring) chamber established on the boat. After a compressor warm-up of 15 minutes, the diving air was measured with the boat at eight different bearings to the wind, each 45 degrees apart at intervals of five minutes. Three of the four gasoline-driven compressor units tested showed presence of carbon monoxide in the breathing air. One diesel-driven unit showed a very low concentration of carbon monoxide (3-4 ppm) and six diesel-driven units showed no detectable carbon monoxide. Although not tested, diesel exhaust emissions could also enter the breathing air by the same route. A locally made modification to the compressor air intake was designed and successfully tested on one gasoline-driven compressor unit. An information sheet on the hazards of carbon monoxide as well as on the modification has been developed for distribution among the villages.

  18. Life in Hot Carbon Monoxide: The Complete Genome Sequence of Carboxydothermus hydrogenoformans Z-2901.

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  19. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Martin Wu

    2005-11-01

    Full Text Available We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  20. Natural clinoptilolite exchanged with iron: characterization and catalytic activity in nitrogen monoxide reduction

    Daria Tito-Ferro

    2016-12-01

    Full Text Available The aim of this work was to characterize the natural clinoptilolite from Tasajeras deposit, Cuba, modified by hydrothermal ion-exchange with solutions of iron (II sulfate and iron (III nitrate in acid medium. Besides this, its catalytic activity to reduce nitrogen monoxide with carbon monoxide/propene in the presence of oxygen was evaluated. The characterization was performed by Mössbauer and UV-Vis diffuse reflectance spectroscopies and adsorption measurements. The obtained results lead to conclude that in exchanged samples, incorporated divalent and trivalent irons are found in octahedral coordination. Both irons should be mainly in cationic extra-framework positions inside clinoptilolite channels as charge compensating cations, and also as iron oxy-hydroxides resulting from limited hydrolysis of these cations. The iron (III exchanged samples has a larger amount of iron oxy-hydroxides agglomerates. The iron (II exchanged samples have additionally iron (II sulfate adsorbed. The catalytic activity in the nitrogen monoxide reduction is higher in the exchanged zeolites than starting. Among all samples, those exchanged of iron (II has the higher catalytic activity. This lead to outline that, main catalytically active centers are associated with divalent iron.

  1. Toxicological Investigation of Acute Carbon Monoxide Poisoning in Four Occupants of a Fuming Sport Utility Vehicle

    Martin Nnoli

    2014-11-01

    Full Text Available Background: This toxicological investigation involves a report on the death of four occupants of a sport utility vehicle on one of the major busy Federal roads of Nigeria where they were held for up to three hours in a traffic jam while the car was steaming. Methods: Autopsy was executed using the standard procedure and toxicological analysis was done using simple spectrophotometric method to establish the level of carboxyhaemoglobin (HbCO in peripheral blood in the four occupants. Results: The autopsy report indicated generalized cyanosis, sub-conjuctival hemorrhages, marked laryngo-trachea edema with severe hyperemia with frothy fluid discharges characteristic of carbon monoxide poisoning. Toxicological report of the level of HbCO in part per million (ppm in the peripheral blood of the four occupants was A= 650 ppm; B= 500 ppm; C= 480 ppm, and D= 495 ppm against the maximum permissible level of 50 ppm. Conclusion: The sudden death of the four occupants was due to excessive inhalation of the carbon monoxide gas from the exhaust fumes leaking into the cabin of the car. The poor road network, numerous potholes, and traffic jam in most of roads in Nigeria could have exacerbated a leaky exhaust of the smoky second hand SUV car leading to the acute carbon monoxide poisoning.

  2. Life in hot carbon monoxide: the complete genome sequence of Carboxydothermus hydrogenoformans Z-2901.

    Wu, Martin; Ren, Qinghu; Durkin, A Scott; Daugherty, Sean C; Brinkac, Lauren M; Dodson, Robert J; Madupu, Ramana; Sullivan, Steven A; Kolonay, James F; Haft, Daniel H; Nelson, William C; Tallon, Luke J; Jones, Kristine M; Ulrich, Luke E; Gonzalez, Juan M; Zhulin, Igor B; Robb, Frank T; Eisen, Jonathan A

    2005-11-01

    We report here the sequencing and analysis of the genome of the thermophilic bacterium Carboxydothermus hydrogenoformans Z-2901. This species is a model for studies of hydrogenogens, which are diverse bacteria and archaea that grow anaerobically utilizing carbon monoxide (CO) as their sole carbon source and water as an electron acceptor, producing carbon dioxide and hydrogen as waste products. Organisms that make use of CO do so through carbon monoxide dehydrogenase complexes. Remarkably, analysis of the genome of C. hydrogenoformans reveals the presence of at least five highly differentiated anaerobic carbon monoxide dehydrogenase complexes, which may in part explain how this species is able to grow so much more rapidly on CO than many other species. Analysis of the genome also has provided many general insights into the metabolism of this organism which should make it easier to use it as a source of biologically produced hydrogen gas. One surprising finding is the presence of many genes previously found only in sporulating species in the Firmicutes Phylum. Although this species is also a Firmicutes, it was not known to sporulate previously. Here we show that it does sporulate and because it is missing many of the genes involved in sporulation in other species, this organism may serve as a "minimal" model for sporulation studies. In addition, using phylogenetic profile analysis, we have identified many uncharacterized gene families found in all known sporulating Firmicutes, but not in any non-sporulating bacteria, including a sigma factor not known to be involved in sporulation previously.

  3. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    Stollenwerk, Tobias

    2013-09-01

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  4. Influence of carbon monoxide poisoning on the fetal heart monitor tracing: a report of 3 cases.

    Towers, Craig V; Corcoran, Vincent A

    2009-03-01

    The diagnosis of carbon monoxide poisoning in the third trimester of pregnancy requires an index of suspicion, and the appearance of the fetal heart monitor tracing may help in this regard. Three cases of third-trimester acute carbon monoxide poisoning occurred. In each pregnancy, the fetal heart monitor tracing on admission was correlated with the maternal carboxyhemoglobin level, and how the pattern changed following the institution of therapy was analyzed. In all 3 cases, the initial fetal heart rate pattern demonstrated decreased variability with an elevated baseline and an absence of accelerations and decelerations. Within 45-90 minutes of treatment onset, the baseline fetal heart rate dropped by 20-40 beats per minute, the variability became moderate, and accelerations occurred. Absent accelerations with minimal variability, if caused by uteroplacental insufficiency, are usually preceded by recurrent decelerations. Absent accelerations with minimal variability in the absence of recurrent decelerations may suggest another cause, of which carbon monoxide intoxication can be added to the differential, especially since this disorder often has nonspecific clinical symptoms.

  5. Ferromagnetic semiconductor-metal transition in heterostructures of electron doped europium monoxide

    Stollenwerk, Tobias

    2013-09-15

    In the present work, we develop and solve a self-consistent theory for the description of the simultaneous ferromagnetic semiconductor-metal transition in electron doped Europium monoxide. We investigate two different types of electron doping, Gadolinium impurities and Oxygen vacancies. Besides the conduction band occupation, we can identify low lying spin fluctuations on magnetic impurities as the driving force behind the doping induced enhancement of the Curie temperature. Moreover, we predict the signatures of these magnetic impurities in the spectra of scanning tunneling microscope experiments. By extending the theory to allow for inhomogeneities in one spatial direction, we are able to investigate thin films and heterostructures of Gadolinium doped Europium monoxide. Here, we are able to reproduce the experimentally observed decrease of the Curie temperature with the film thickness. This behavior is attributed to missing coupling partners of the localized 4f moments as well as to an electron depletion at the surface which leads to a reduction of the number of itinerant electrons. By investigating the influence of a metallic substrate onto the phase transition in Gadolinium doped Europium monoxide, we find that the Curie temperature can be increased up to 20%. However, as we show, the underlying mechanism of metal-interface induced charge carrier accumulation is inextricably connected to a suppression of the semiconductor-metal transition.

  6. Acute wood or coal exposure with carbon monoxide intoxication induces sister chromatid exchange

    Ozturk, S.; Vatansever, S.; Cefle, K.; Palanduz, S.; Guler, K.; Erten, N.; Erk, O.; Karan, M.A.; Tascioglu, C. [University of Istanbul, Istanbul (Turkey). Istanbul Faculty of Medicine

    2002-07-01

    The object of this study was to investigate the genotoxic effect of acute overexposure to combustion products originating from coal or wood stoves in patients presenting with acute carbon monoxide intoxication. The authors analyzed the frequency of sister chromatid exchange and the carboxyhemoglobin concentration in 20 consecutive patients without a history of smoking or drug use who had been treated in the Emergency Care Unit of Istanbul Medical Faculty due to acute carbon monoxide intoxication. All of these cases were domestic accidents due to dysfunctioning coal or wood stoves. The results were compared with a control group of 20 nonsmoking, nondrug-using healthy individuals matched for age, sex, and absence of other chemical exposure. It was concluded that acute exposure to combustion products of wood or coal is genotoxic to DNA. Potential causes of genotoxicity include known mutagenic compounds present in coal or wood smoke and ash, oxygen radicals formed during combustion, as well as hypoxic and reperfusion injury mechanisms initiated by carbon monoxide intoxication.

  7. Carbon monoxide - hydrogen combustion characteristics in severe accident containment conditions. Final report

    2000-03-01

    Carbon monoxide can be produced in severe accidents from interaction of ex-vessel molten core with concrete. Depending on the particular core-melt scenario, the type of concrete and geometric factors affecting the interaction, the quantities of carbon monoxide produced can vary widely, up to several volume percent in the containment. Carbon monoxide is a combustible gas. The carbon monoxide thus produced is in addition to the hydrogen produced by metal-water reactions and by radiolysis, and represents a possibly significant contribution to the combustible gas inventory in the containment. Assessment of possible accident loads to containment thus requires knowledge of the combustion properties of both CO and H 2 in the containment atmosphere. Extensive studies have been carried out and are still continuing in the nuclear industry to assess the threat of hydrogen in a severe reactor accident. However the contribution of carbon monoxide to the combustion threat has received less attention. Assessment of scenarios involving ex-vessel interactions require additional attention to the potential contribution of carbon monoxide to combustion loads in containment, as well as the effectiveness of mitigation measures designed for hydrogen to effectively deal with particular aspects of carbon monoxide. The topic of core-concrete interactions has been extensively studied; for more complete background on the issue and on the physical/thermal-hydraulics phenomena involved, the reader is referred to Proceedings of CSNI Specialists Meetings (Ritzman, 1987; Alsmeyer, 1992) and a State-of-Art Report (European Commission, 1995). The exact amount of carbon monoxide present in a reactor pit or in various compartments (or rooms) in a containment building is specific to the type of concrete and the accident scenario considered. Generally, concrete containing limestone and sand have a high percentage of CaCO 3 . Appendix A provides an example of results of estimates of CO and CO 2

  8. Unintentional carbon monoxide poisoning hospitalization and emergency department counts and rates by county, year, and fire-relatedness among California residents,2000-2007

    California Environmental Health Tracking Program — This dataset contains case counts, rates, and confidence intervals of unintentional carbon monoxide poisoning (CO) inpatient hospitalizations and emergency...

  9. Ambient carbon monoxide and cardiovascular mortality: a nationwide time-series analysis in 272 cities in China.

    Liu, Cong; Yin, Peng; Chen, Renjie; Meng, Xia; Wang, Lijun; Niu, Yue; Lin, Zhijing; Liu, Yunning; Liu, Jiangmei; Qi, Jinlei; You, Jinling; Kan, Haidong; Zhou, Maigeng

    2018-01-01

    Evidence of the acute health effects of ambient carbon monoxide air pollution in developing countries is scarce and mixed. We aimed to evaluate short-term associations between carbon monoxide and daily cardiovascular disease mortality in China. We did a nationwide time-series analysis in 272 major cities in China from January, 2013, to December, 2015. We extracted daily cardiovascular disease mortality data from China's Disease Surveillance Points system. Data on daily carbon monoxide concentrations for each city were obtained from the National Urban Air Quality Real-time Publishing Platform. City-specific associations between carbon monoxide concentrations and daily mortality from cardiovascular disease, coronary heart disease, and stroke were estimated with over-dispersed generalised linear models. Bayesian hierarchical models were used to obtain national and regional average associations. Exposure-response association curves and potential effect modifiers were evaluated. Two-pollutant models were fit to evaluate the robustness of the effects of carbon monoxide on cardiovascular mortality. The average annual mean carbon monoxide concentration in these cities from 2013 to 2015 was 1·20 mg/m 3 , ranging from 0·43 mg/m 3 to 2·45 mg/m 3 . For a 1 mg/m 3 increase in average carbon monoxide concentrations on the present day and previous day (lag 0-1), we observed significant increments in mortality of 1·12% (95% posterior interval [PI] 0·42-1·83) from cardiovascular disease, 1·75% (0·85-2·66) from coronary heart disease, and 0·88% (0·07-1·69) from stroke. These associations did not vary substantially by city, region, and demographic characteristics (age, sex, and level of education), and the associations for cardiovascular disease and coronary heart disease were robust to the adjustment of criteria co-pollutants. We did not find a threshold below which carbon monoxide exposure had no effect on cardiovascular disease mortality. This analysis is, to our

  10. A Rare Cause of Chronic Headache that May Be Misdiagnosed as Migraine: Chronic Carbon Monoxide Poisoning

    Mehmet Kenan KANBUROGLU

    2014-09-01

    Full Text Available SUMMARY: Differential diagnosis of primary headache disorders can be challenging for physicians. Although the association of headache with acute carbon monoxide intoxication is very well-defined, in refractory nonspecific headaches associated with chronic low dose exposure to carbon monoxide, CO intoxication is usually overlooked, mostly due to vague symptoms. Herein we present a 15-year-old female patient with chronic carbon monoxide poisoning who was undergoing two years of follow-up care for migraines. Chronic carbon monoxide intoxication may mimic the episodic nature and familial predisposition of migraine attacks. Normal carboxyhemoglobin levels do not exclude the diagnosis, and smoking is a confounding factor. In emergency rooms, patients presenting with headaches had higher levels of carboxyhemoglobin, but, as far as we know, there have been no studies investigating carboxyhemoglobin levels in migraine patients. Chronic carbon monoxide poisoning should be suspected in migraine patients, especially if the attacks occur during winter months. ÖZET: Primer baş ağrısında ayırıcı tanının yapılması bazen doktorlar açısından zor olabilmektedir. Literatürde karbon monoksit ile baş ağrısı arasındaki ilişki çok iyi ortaya konulmuş olmasına karşın, dirençli ve nonspesifik başağrısı nedenlerinden biri olan kronik düşük doz karbon monoksit maruziyeti kendine özgü bulgusu olmadığından sıklıkla atlanmaktadır. Bu yazıda, iki yıl migren tanısı ile takip ve tedavi edilen kronik karbon monoksit zehirlenmesi olan bir olgu sunuldu. Kronik karbon monoksit zehirlenmesi epizodik paterni ve aile fertlerinde benzer şikayetlerin olması nedeniyle migren ataklarını andırabilmektedir. Karboksihemoglobin konsantrasyonlarının normal saptanması tanıyı ekarte ettirmemekte, ayrıca sigara kullanımı da karıştırıcı bir faktör olabilmektedir. Acil servislerine baş ağrısı ile başvuran hastalar

  11. Carbon monoxide and methane adsorption of crude oil refinery using activated carbon from palm shells as biosorbent

    Yuliusman; Afdhol, M. K.; Sanal, Alristo

    2018-03-01

    Carbon monoxide and methane gas are widely present in oil refineries. Off-potential gas is used as raw material for the petrochemical industry. In order for this off-gas to be utilized, carbon monoxide and methane must be removed from off-gas. This study aims to adsorb carbon monoxide and methane using activated carbon of palm shells and commercial activated carbon simultaneously. This research was conducted in 2 stages: 1) Preparation and characterization of activated carbon, 2) Carbon monoxide and methane adsorption test. The activation experiments using carbon dioxide at a flow rate of 150 ml/min yielded a surface area of 978.29 m2/g, Nitrogen at flow rate 150 ml/min yielded surface area 1241.48 m2/g, and carbon dioxide and nitrogen at a flow rate 200 ml/min yielded a surface area 300.37 m2/g. Adsorption of carbon monoxide and methane on activated carbon of palm shell systems yielded results in the amount of 0.5485 mg/g and 0.0649 mg/g and using commercial activated carbon yielded results in the amount of 0.5480 mg/g and 0.0650 mg/g

  12. Systemic Administration of Carbon Monoxide-Releasing Molecule-3 Protects the Skeletal Muscle in Porcine Model of Compartment Syndrome.

    Bihari, Aurelia; Cepinskas, Gediminas; Sanders, David; Lawendy, Abdel-Rahman

    2018-05-01

    Acute limb compartment syndrome, a complication of musculoskeletal trauma, results in muscle necrosis and cell death. Carbon monoxide, liberated from the carbon monoxide-releasing molecule-3, has been shown protective in a rat model of compartment syndrome. The purpose of this study was to test the effect of carbon monoxide-releasing molecule-3 in a preclinical large animal model of compartment syndrome, with the ultimate goal of developing a pharmacologic adjunct treatment for compartment syndrome. Animal research study. Basic research laboratory in a hospital setting. Male Yorkshire-Landrace pigs (50-60 kg). Pigs underwent 6 hours of intracompartmental pressure elevation by infusing fluid into the anterior compartment of the right hind limb. Carbon monoxide-releasing molecule-3 was administered systemically (2 mg/kg, IV) at fasciotomy, followed by 3-hour reperfusion. Muscle perfusion, inflammation, injury, and apoptosis were assessed in the skeletal muscle. Systemic leukocyte activation was assessed during compartment syndrome and reperfusion. Elevation of hind limb intracompartmental pressure resulted in significant microvascular perfusion deficits (44% ± 1% continuously perfused capillaries in compartment syndrome vs 76% ± 4% in sham; p molecule-3 at fasciotomy increased the number of continuously perfused capillaries (68% ± 3%; p molecule-3 at fasciotomy offered protection against compartment syndrome-induced microvascular perfusion deficit, tissue injury, and systemic leukocyte activation. The data suggest the potential therapeutic application of carbon monoxide-releasing molecule-3 to patients at risk of developing compartment syndrome.

  13. An operando FTIR spectroscopic and kinetic study of carbon monoxide pressure influence on rhodium-catalyzed olefin hydroformylation.

    Kubis, Christoph; Sawall, Mathias; Block, Axel; Neymeyr, Klaus; Ludwig, Ralf; Börner, Armin; Selent, Detlef

    2014-09-08

    The influence of carbon monoxide concentration on the kinetics of the hydroformylation of 3,3-dimethyl-1-butene with a phosphite-modified rhodium catalyst has been studied for the pressure range p(CO)=0.20-3.83 MPa. Highly resolved time-dependent concentration profiles of the organometallic intermediates were derived from IR spectroscopic data collected in situ for the entire olefin-conversion range. The dynamics of the catalyst and organic components are described by enzyme-type kinetics with competitive and uncompetitive inhibition reactions involving carbon monoxide taken into account. Saturation of the alkyl-rhodium intermediates with carbon monoxide as a cosubstrate occurs between 1.5 and 2 MPa of carbon monoxide pressure, which brings about a convergence of aldehyde regioselectivity. Hydrogenolysis of the acyl intermediate is fast at 30 °C and low pressure of p(CO)=0.2 MPa, but is of minus first order with respect to the solution concentration of carbon monoxide. Resting 18-electron hydrido and acyl complexes that correspond to early and late rate-determining states, respectively, coexist as long as the conversion of the substrate is not complete. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Treatment in carbon monoxide poisoning patients with headache: a prospective, multicenter, double-blind, controlled clinical trial.

    Ocak, Tarik; Tekin, Erdal; Basturk, Mustafa; Duran, Arif; Serinken, Mustafa; Emet, Mucahit

    2016-11-01

    There is a lack of specificity of the analgesic agents used to treat headache and underlying acute carbon monoxide poisoning. To compare effectiveness of "oxygen alone" vs "metoclopramide plus oxygen" vs "metamizole plus oxygen" therapy in treating carbon monoxide-induced headache. A prospective, multicenter, double-blind, controlled trial. Three emergency departments in Turkey. Adult carbon monoxide poisoning patients with headache. A total of 117 carbon monoxide-intoxicated patients with headache were randomized into 3 groups and assessed at baseline, 30 minutes, 90 minutes, and 4 hours. The primary outcome was patient-reported improvement rates for headache. Secondary end points included nausea, need for rescue medication during treatment, and reduction in carboxyhemoglobin levels. During observation, there was no statistical difference between drug type and visual analog scale score change at 30 minutes, 90 minutes, or 4 hours, for either headache or nausea. No rescue medication was needed during the study period. The reduction in carboxyhemoglobin levels did not differ among the 3 groups. The use of "oxygen alone" is as efficacious as "oxygen plus metoclopramide" or "oxygen plus metamizole sodium" in the treatment of carbon monoxide-induced headache. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Effect of N-Acetylcysteine in Protecting from Simultaneous Noise and Carbon Monoxide Induced Hair Cell Loss

    Akram Pourbakht

    2011-06-01

    Full Text Available Background and Aim: N-acetylcysteine, a glutathione precursor and reactive oxygen species scavenger, is reported to be effective in reducing noise-induced hearing loss. Many workers in industry are exposed simultaneously to noise and chemical pollutants such as carbon monoxide. We investigated effectiveness of N-acetylcysteine in protecting the cochlea from simultaneous noise and carbon monoxide damages.Methods: Twelve rabbits were exposed simeltaneously to 100 dB sound pressure level of broad band noise and carbon monoxide 8 hours a day for 5 days. One hour before exposure, experimental group received 325 mg/kg of N-acetylcysteine while normal saline was administered for the control group. The protective effect of N-acetylcysteine was evaluated 3 weeks after exposure by histological assessment of the hair cells.Results: Simultaneous exposure to noise and carbon monoxide resulted in a considerable damage to the outer hair cells; however, the inner hair cells and the pillar cells remained intact. Use of N-acetylcysteine in the experimental group significantly reduced the extent of outer hair cell loss.Conclusion: N-acetylcysteine attenuates simultaneous noise and carbon monoxide induced hair cell damage in rabbits.

  16. Analysis of patients presenting to the emergency department with carbon monoxide intoxication

    Selim Yurtseven

    2015-12-01

    Full Text Available Objectives: Carbon monoxide is a potentially fatal form of poisoning. The exact incidence is unclear, due to cases being undiagnosed or reported as fewer than the real number. Hyperbaric oxygen therapy (HBOT is of proven efficacy in the treatment of CO intoxication.The purpose of this study was to describe the general characteristics of carbon monoxide (CO intoxications presenting to the emergency department and to investigate troponin I values and the effectiveness of hyperbaric oxygen therapy (HBOT in these patients. Material and methods: Patients presenting to the emergency department with CO intoxication over one year and patients with such intoxications receiving HBOT were examined retrospectively. Results: One hundred seventy-one patients were included; 140 (81.9% were poisoned by stoves, 18 (10.5% by hot water boilers and 10 in (5.8% by fires. COHb levels were normal in 49 of the 163 patients whose values were investigated, and were elevated in 114 patients. Mean COHb value was 16.6. Troponin I values were investigated in 112 patients. These were normal in 86 patients and elevated in 26. Mean troponin I value was 0.38 ng/ml. One hundred twenty-three of the 171 patients in the study were discharged in a healthy condition after receiving normobaric oxygen therapy, while 48 patients received HBOT. Forty-two (87.5% of the patients receiving HBOT were discharged in a healthy condition while sequelae persisted in five (10.4%. One patient died after 15 session of HBOT. Conclusion: Although elevated carboxyhemoglobin confirms diagnosis of CO intoxication, normal levels do not exclude it. Troponin I levels may rise in CO intoxication. No significant relation was observed between carboxyhemoglobin and receipt of HBOT. A significant correlation was seen, however, between troponin I levels and receipt of HBOT. Keywords: Carbon monoxide intoxication, Hyperbaric oxygen, Troponin I, Echocardiography

  17. Silicon Monoxide at 1 atm and Elevated Pressures: Crystalline or Amorphous?

    AlKaabi, Khalid

    2014-03-05

    The absence of a crystalline SiO phase under ordinary conditions is an anomaly in the sequence of group 14 monoxides. We explore theoretically ordered ground-state and amorphous structures for SiO at P = 1 atm, and crystalline phases also at pressures up to 200 GPa. Several competitive ground-state P = 1 atm structures are found, perforce with Si-Si bonds, and possessing Si-O-Si bridges similar to those in silica (SiO2) polymorphs. The most stable of these static structures is enthalpically just a little more stable than a calculated random bond model of amorphous SiO. In that model we find no segregation into regions of amorphous Si and amorphous SiO2. The P = 1 atm structures are all semiconducting. As the pressure is increased, intriguing new crystalline structures evolve, incorporating Si triangular nets or strips and stishovite-like regions. A heat of formation of crystalline SiO is computed; it is found to be the most negative of all the group 14 monoxides. Yet, given the stability of SiO2, the disproportionation 2SiO (s) → Si(s)+SiO2(s) is exothermic, falling right into the series of group 14 monoxides, and ranging from a highly negative ΔH of disproportionation for CO to highly positive for PbO. There is no major change in the heat of disproportionation with pressure, i.e., no range of stability of SiO with respect to SiO2. The high-pressure SiO phases are metallic. © 2014 American Chemical Society.

  18. A Southern Hemisphere atmospheric history of carbon monoxide from South Pole firn air

    Verhulst, K. R.; Aydin, M.; Novelli, P. C.; Holmes, C. D.; Prather, M. J.; Saltzman, E. S.

    2013-12-01

    Carbon monoxide (CO) is a reactive trace gas and is important to tropospheric photochemistry as a major sink of hydroxyl radicals (OH). Major sources of CO are fossil fuel combustion, linked mostly to automotive emissions, biomass burning, and oxidation of atmospheric methane. Understanding changes in carbon monoxide over the past century will improve our understanding of man's influence on the reactivity of the atmosphere. Little observational information is available about CO levels and emissions prior to the 1990s, particularly for the Southern Hemisphere. The NOAA global flask network provides the most complete instrumental record of CO, extending back to 1988. Annually averaged surface flask measurements suggest atmospheric CO levels at South Pole were relatively stable from 2004-2009 at about 51 nmol mol-1 [Novelli and Masarie, 2013]. In this study, a 20th century atmospheric history of CO is reconstructed from South Pole firn air measurements, using a 1-D firn air diffusion model. Firn air samples were collected in glass flasks from two adjacent holes drilled from the surface to 118 m at South Pole, Antarctica during the 2008/2009 field season and CO analysis was carried out by NOAA/CCG. Carbon monoxide levels increase from about 45 nmol mol-1 in the deepest firn sample at 116 m to 52 nmol mol-1 at 107 m, and remain constant at about 51-52 nmol mol-1 at shallower depths. Atmospheric histories based on the firn air reconstructions suggest that CO levels over Antarctica increased by roughly 40% (from about 36 to 50 nmol mol-1) between 1930-1990, at a rate of about 0.18 nmol mol-1 yr-1. Firn air and surface air results suggest the rate of CO increase at South Pole slowed considerably after 1990. The firn air-based atmospheric history is used to infer changes in Southern Hemisphere CO emissions over the 20th century.

  19. Determining the diagnostic value of endogenous carbon monoxide in Chronic Obstructive Pulmonary Disease exacerbations

    Dogan, N. O.; Corbacioglu, S. K.; Bildik, F.; Kilicaslan, I.; Hakoglu, O.; Gunaydin, G. P.; Cevik, Y.; Ulker, V.; Gokcen, E.

    2014-01-01

    Objective: To determine whether endogenous carbon monoxide levels in exacerbations of Chronic Obstructive Pulmonary Disease patients were higher compared to healthy individuals and to investigate alteration of carbon monoxide levels across the three different severity stages of Global Initiative for Chronic Obstructive Lung Disease criteria related to Chronic Obstructive Pulmonary Disease exacerbations. Methods: The prospective study was conducted from January to March 2011 at two medical institutions in Ankara, Turkey, and comprised patients of acute Chronic Obstructive Pulmonary Disease exacerbations. The severity of the exacerbations was based on the Global Initiative for Chronic Obstructive Lung Disease criteria. Patients with active tobacco smoking, suspicious carbon monoxide poisoning and uncertain diagnosis were excluded. healthy control subjects who did not have any comorbid diseases and smoking habitus were also enrolled to compare the differences between carboxyhaemoglobin levels A two-tailed Mann-Whitney U test with Bonferroni correction was done following a Kruskal-Wallis test for statistical purposes. Results: There were 90 patients and 81 controls in the study. Carboxyhaemoglobin levels were higher in the patients than the controls (p<0.001). As for the three severity stages, Group 1 had a median carboxyhaemoglobin of 1.6 (0.95-2.00). The corresponding levels in Group 2 (1.8 (1.38-2.20)) and Group 3 (1.9 (1.5-3.0)) were higher than the controls (p<0.001 and p<0.005 respectively). No statistically significant difference between Group 1 and the controls (1.30 (1.10-1.55)) was observed (p<0.434). Conclusion: Carboxyhaemoglobin levels were significantly higher in exacerbations compared with the normal population. Also, in more serious exacerbations, carboxyhaemoglobin levels were significantly increased compared with healthy individuals and mild exacerbations. (author)

  20. Intermittent, low dose carbon monoxide exposure enhances survival and dopaminergic differentiation of human neural stem cells

    Dreyer-Andersen, Nanna; Almeida, Ana Sofia; Jensen, Pia

    2018-01-01

    Exploratory studies using human fetal tissue have suggested that intrastriatal transplantation of dopaminergic neurons may become a future treatment for patients with Parkinson's disease. However, the use of human fetal tissue is compromised by ethical, regulatory and practical concerns. Human stem...... cells constitute an alternative source of cells for transplantation in Parkinson's disease, but efficient protocols for controlled dopaminergic differentiation need to be developed. Short-term, low-level carbon monoxide (CO) exposure has been shown to affect signaling in several tissues, resulting...... in Parkinson's disease....

  1. Effect of Carbon Monoxide on Active Oxygen Metabolism of Postharvest Jujube

    Shaoying Zhang; Qin Li; Yulan Mao

    2014-01-01

    To prolong the shelf life postharvest jujube, the effect of carbon monoxide (CO) on senescence of postharvest jujube in relation to active oxygen metabolism was investigated. Jujubes were fumigated with CO gas at 5, 10, 20 or 40μmol/L for 1 h, and then stored for 30 days at room temperature. Changes in membrane permeability, malonaldehyde (MDA), H2O2, O2•− content, and activities of active oxygen metabolism associated enzymes including superoxide dismutase (SOD), catalase (CAT) and peroxidase...

  2. Convergence of quasiparticle self-consistent GW calculations of transition metal monoxides

    Das, Suvadip; Coulter, John E.; Manousakis, Efstratios

    2014-01-01

    Finding an accurate ab initio approach for calculating the electronic properties of transition metal oxides has been a problem for several decades. In this paper, we investigate the electronic structure of the transition metal monoxides MnO, CoO, and NiO in their undistorted rock-salt structure within a fully iterated quasiparticle self-consistent GW (QPscGW) scheme. We study the convergence of the QPscGW method, i.e., how the quasiparticle energy eigenvalues and wavefunctions converge as a f...

  3. The relation between carbon monoxide emission and visual extinction in cloud L134

    Tucker, K.D.; Dickman, R.L.; Encrenaz, P.J.; Kutner, M.L.

    1976-01-01

    Emission from the J=1→0 transition of carbon monoxide has been mapped over an area of 40' x 55' in cloud L134, and visual extinctions over the entire cloud have been obtained by means of star counts. Line intensities of > or =2 K are observable down to an extinction level of about one magnitude. From observations of the J=1→0 transition of the 13 CO isotopic species at 18 locations in the cloud, we have found a linear correlation between the local thermodynamic equilibrium (LTE) column densities of 13 CO and magnitudes of visual extinction

  4. Copolymerization of carbon monoxide and styrene catalyzed by resin-supported palladium polymer

    2007-02-01

    Full Text Available Polyketone was prepared by the copolymerization of carbon monoxide (CO and styrene (ST catalyzed by o-phenylenediamine resin-supported palladium acetate. Effects of each catalytic system component such as 2,2’-bipyridine, 1,4-quinone and p-toluene-sulphonate on the copolymerization were investigated. The resin-supported catalyst and the copolymerization product were characterized by infrared spectroscopy (IR, differential scanning calorimetry (DSC, thermogravimetry (TG, X-ray photoelectron spectroscopy (XPS, Scanning Electron Microscopy (SEM. Results indicated that the resin-supported catalyst has excellent catalytic property. Furthermore, partial catalytic activity was maintained after the catalyst was used for five times.

  5. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    Wang, Yao

    2017-04-12

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  6. Clinical and neuropathological findings of acute carbon monoxide toxicity in chihuahuas following smoke inhalation.

    Kent, Marc; Creevy, Kate E; Delahunta, Alexander

    2010-01-01

    Three adult Chihuahuas were presented for evaluation after smoke inhalation during a house fire. All three dogs received supportive care and supplemental oxygen. After initial improvement, the dogs developed seizures. Despite anticonvulsant therapy and supportive care, the dogs died. The brains of two dogs were examined. Lesions were identified that were compatible with acute carbon monoxide (CO) toxicity. Lesions were confined to the caudate nucleus, the globus pallidus, and the substantia nigra bilaterally, as well as the cerebellum, cerebral cortex, and dorsal thalamus. This case report describes the clinicopathological sequelae in acute CO toxicity.

  7. High Resolution Spectra of Carbon Monoxide, Propane and Ammonia for Atmospheric Remote Sensing

    Beale, Christopher Andrew

    Spectroscopy is a critical tool for analyzing atmospheric data. Identification of atmospheric parameters such as temperature, pressure and the existence and concentrations of constituent gases via remote sensing techniques are only possible with spectroscopic data. These form the basis of model atmospheres which may be compared to observations to determine such parameters. To this end, this dissertation explores the spectroscopy of three molecules: ammonia, propane and carbon monoxide. Infrared spectra have been recorded for ammonia in the region 2400-9000 cm-1. These spectra were recorded at elevated temperatures (from 293-973 K) using a Fourier Transform Spectrometer (FTS). Comparison between the spectra recorded at different temperatures yielded experimental lower state energies. These spectra resulted in the measurement of roughly 30000 lines and about 3000 quantum assignments. In addition spectra of propane were recorded at elevated temperatures (296-700 K) using an FTS. Atmospheres with high temperatures require molecular data at appropriate conditions. This dissertation describes collection of such data and the potential application to atmospheres in our solar system, such as auroral regions in Jupiter, to those of planets orbiting around other stars and cool sub-stellar objects known as brown dwarfs. The spectra of propane and ammonia provide the highest resolution and most complete experimental study of these gases in their respective spectral regions at elevated temperatures. Detection of ammonia in an exoplanet or detection of propane in the atmosphere of Jupiter will most likely rely on the work presented here. The best laboratory that we have to study atmospheres is our own planet. The same techniques that are applied to these alien atmospheres originated on Earth. As such it is appropriate to discuss remote sensing of our own atmosphere. This idea is explored through analysis of spectroscopic data recorded by an FTS on the Atmospheric Chemistry

  8. The eight micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    Geballe, T.R.; Lacy, J.H.; Beck, S.C.

    1978-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (600 K) layers of a circumstellar cloud at a distance of roughly 0.15 minutes from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is proabably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial

  9. The 8 micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    Geballe, T. R.; Lacy, J. H.; Beck, S. C.

    1979-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (about 600 K) layers of a circumstellar cloud at a distance of approximately 0.15 arcsec from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is probably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial.

  10. The eight micron band of silicon monoxide in the expanding cloud around VY Canis Majoris

    Geballe, T. R.; Lacy, J. H.; Beck, S. C.

    1978-01-01

    Observations of vibration-rotation transitions of silicon monoxide in VY CMa show that the lines originate in accelerating, expanding, and cool (600 K) layers of a circumstellar cloud at a distance of roughly 0.15 minutes from the central star. The central stellar velocity, as estimated from observed SiO P Cygni line profiles, is somewhat redshifted from the midpoint of the maser emission features. Most of the silicon is probably in the form of dust grains. The isotopic ratios of silicon are nearly terrestrial.

  11. FTIR study of carbon monoxide adsorption on ion-exchanged X, Y and mordenite type zeolites

    R. HERCIGONJA

    2003-05-01

    Full Text Available In this work Fourier transform infrared (FTIR study has been applied to study the adsorption of carbon monoxide on transition metal (Mn+, Co2+, Ni2+ ion-exchanged zeolites type Y, X and mordenites. The adsorption of CO at room temperature produces overlapping IR absorption bands in the 2120–2200 cm-1 region. The frequency of the band around 2200 cm-1 is found to be dependent not only on the charge-balancing transition metal cation, but also on the framework composition. The frequencies of the band near 1600 cm-1 was found to be dependent on the Si/Al ratio of the investigated zeolites.

  12. Gas-phase studies of AunOm+ interacting with carbon monoxide

    Kimble, M. L.; Castleman, A. W.

    2004-04-01

    The results of reactions between preformed cationic gold oxide clusters and carbon monoxide have been investigated utilizing a fast-flow reactor mass spectrometer. From these studies, it was found that all AunOm+ produced in the cluster source disappeared with CO addition at the reactant gas inlet. Furthermore, with CO addition, intermediate peaks of the form AunOm(CO)x+ (n=1-2, m=0-3, x=0-2) were produced, with some of the species continuing to react at higher CO flows.

  13. Metal cluster cation reactions: Carbon monoxide association to Cu + n ions

    Leuchtner, R. E.; Harms, A. C.; Castleman, A. W., Jr.

    1990-06-01

    Copper cluster cations (Cu+n,n=1-14) were produced in a laser vaporization/flow tube apparatus and equilibrated to room temperature. The association rate constants of carbon monoxide onto these ions were measured; low-pressure, termolecular behavior was observed for the smaller species while for clusters greater than Cu+7, the longer lifetimes due to the increased number of degrees of freedom leads to pressure independence (>0.3 Torr) of the effective bimolecular rates. Unimolecular decay theory (RRKM) is used to explain the overall trend and when intrinsic surface site reactivity is taken into account, excellent agreement with measured reactivity is obtained.

  14. Carbon monoxide migratory insertion - A comparison of cationic and neutral palladium(II) complexes

    Frankcombe, K.; Cavell, K.J.; Yates, B.F.; Knott, R.B.

    1998-01-01

    With the use of ANSTO's resources and expertise and with support from AINSE, we have carried out extensive computer modelling on the mechanism of the palladium catalysed carbonylation reaction, a process which is used industrially in the conversion of carbon monoxide into biodegradable polymers. In this project, experimental and theoretical work has focussed on using Pd(II) complexes containing pyridine carboxylate ligands (NC 5 H 4 COO ) to explore the fundamental mechanistic steps. The results for subsequent steps in the catalytic cycle are presented and their implication for the design of more efficient catalysts are discussed

  15. CO2 Reduction Catalyzed by Nitrogenase: Pathways to Formate, Carbon Monoxide, and Methane

    Khadka, Nimesh; Dean, Dennis R.; Smith, Dayle; Hoffman, Brian M.; Raugei, Simone; Seefeldt, Lance C.

    2016-01-01

    The reduction of N2 to NH3 by Mo-dependent nitrogenase at its active-site metal cluster FeMo-cofactor utilizes reductive elimination (re) of Fe-bound hydrides with obligatory loss of H2 to activate the enzyme for binding/reduction of N2. Earlier work showed that wild type nitrogenase and a nitrogenase having amino acid substitutions in the MoFe protein near FeMo-cofactor can catalytically reduce CO2 by 2 or 8 electrons/protons to carbon monoxide (CO) and methane (CH4) at low rates. Here, it i...

  16. 1H MR spectroscopy of gray and white matter in carbon monoxide poisoning

    Kondziella, D.; Danielsen, E.R.; Hansen, K.

    2009-01-01

    Carbon monoxide (CO) intoxication leads to acute and chronic neurological deficits, but little is known about the specific noxious mechanisms. (1)H magnetic resonance spectroscopy (MRS) may allow insight into the pathophysiology of CO poisoning by monitoring neurochemical disturbances, yet only......, magnetic resonance imaging (MRI) and neuropsychological testing. Five patients suffered from acute high-dose CO intoxication and were in coma for 1-6 days. In these patients, MRI revealed hyperintensities of the white matter and globus pallidus and also showed increased choline (Cho) and decreased N...

  17. Microbial fuel cell-based biosensor for toxic carbon monoxide monitoring

    Zhou, Shaofeng; Huang, Shaobin; Li, Yi

    2018-01-01

    This study presents an innovative microbial fuel cell-based biosensor for carbon monoxide (CO) monitoring. The hypothesis for the function of the biosensor is that CO inhibits bacterial activity in the anode and thereby reduces electricity production. A mature electrochemically active biofilm...... increasing CO concentration over 70%. Besides, the response time of the biosensor was 1 h. The compact design and simple operation of the biosensor makes it easy to be integrated in existing CO-based industrial facilities either as a forewarning sensor for CO toxicity or even as an individual on...

  18. Analysis of carbon monoxide production in multihundred-watt heat sources

    Peterson, D.E.; Mulford, R.N.R.

    1976-05-01

    The production of carbon monoxide observed within Multihundred Watt heat sources placed under storage conditions was analyzed. Results of compositional and isotopic analyses of gas taps performed on eight heat sources are summarized and interpreted. Several proposed CO generation mechanisms are examined theoretically and assessed by applying thermodynamic principles. Outgassing of the heat source graphite followed by oxygen isotopic exchange through the vent assemblies appears to explain the CO production at storage temperatures. Reduction of the plutonia fuel sphere by the CO is examined as a function of temperature and stoichiometry. Experiments that could be performed to investigate possible CO generation mechanisms are discussed

  19. Lead Monoxide: Two-Dimensional Ferromagnetic Semiconductor Induced by Hole-Doping

    Wang, Yao; Zhang, Qingyun; Shen, Qian; Cheng, Yingchun; Schwingenschlö gl, Udo; Huang, Wei

    2017-01-01

    We employ first-principles calculations to demonstrate ferromagnetic ground states for single- and multi-layer lead monoxide (PbO) under hole-doping, originating from a van Hove singularity at the valence band edge. Both the sample thickness and applied strain are found to have huge effects on the electronic and magnetic properties. Multi-layer PbO is an indirect band gap semiconductor, while a direct band gap is realized in the single-layer limit. In hole-doped single-layer PbO, biaxial tensile strain can enhance the stability of the ferromagnetic state.

  20. Atomic hydrogen and diatomic titanium-monoxide molecular spectroscopy in laser-induced plasma

    Parigger, Christian G.; Woods, Alexander C.

    2017-03-01

    This article gives a brief review of experimental studies of hydrogen Balmer series emission spectra. Ongoing research aims to evaluate early plasma evolution following optical breakdown in laboratory air. Of interest is as well laser ablation of metallic titanium and characterization of plasma evolution. Emission of titanium monoxide is discussed together with modeling of diatomic spectra to infer temperature. The behavior of titanium particles in plasma draws research interests ranging from the modeling of stellar atmospheres to the enhancement of thin film production via pulsed laser deposition.

  1. Non-intentional motor vehicle-related carbon monoxide deaths-revisited

    Copeland, A.R.

    1986-01-01

    A study of non-intentional, motor vehicle-related, carbon monoxide-related deaths was performed on the case files of the Office of the Medical Examiner of Metropolitan Dade Country in Miami, FL (USA) during the years 1980-1984. A total of 15 cases were collected during that time period. These are presented in some detail. A discussion ensues that compares the similar circumstances of these cases, notably running the engine of an automobile in an enclosed space, with older reports in the literature which emphasized defective vehicle exhaust systems as the leading etiology for these deaths.

  2. Detection of the J = 6→5 transition of carbon monoxide

    Goldsmith, P.F.; Erickson, N.R.; Fetterman, H.R.; Clifton, B.J.; Peck, D.D.; Tannenwald, P.E.; Koepf, G.A.; Buhl, D.; McAvoy, N.

    1981-01-01

    The J = 6→5 rotational transition of carbon monoxide has been detected in emission from the KL ''plateau source'' in the Orion molecular cloud. The corrected peak antenna temperature is 100 K, and the FWHM line width is 26 km s -1 . These observations were carried out using the 3 m telescope of the NASA IRTF (Infrared Telescope Facility) on Mauna Kea, Hawaii, and constitute the first astronomical data obtained at submillimeter wavelengths with a heterodyne system using a laser local oscillator. Our data support the idea that the high-velocity dispersion CO in Orion is optically thin and set a lower limit to its temperature of approx.180 K

  3. Carbon monoxide production from five volatile anesthetics in dry sodalime in a patient model: halothane and sevoflurane do produce carbon monoxide; temperature is a poor predictor of carbon monoxide production

    Perez Roberto SGM

    2005-06-01

    Full Text Available Abstract Background Desflurane and enflurane have been reported to produce substantial amounts of carbon monoxide (CO in desiccated sodalime. Isoflurane is said to produce less CO and sevoflurane and halothane should produce no CO at all. The purpose of this study is to measure the maximum amounts of CO production for all modern volatile anesthetics, with completely dry sodalime. We also tried to establish a relationship between CO production and temperature increase inside the sodalime. Methods A patient model was simulated using a circle anesthesia system connected to an artificial lung. Completely desiccated sodalime (950 grams was used in this system. A low flow anesthesia (500 ml/min was maintained using nitrous oxide with desflurane, enflurane, isoflurane, halothane or sevoflurane. For immediate quantification of CO production a portable gas chromatograph was used. Temperature was measured within the sodalime container. Results Peak concentrations of CO were very high with desflurane and enflurane (14262 and 10654 ppm respectively. It was lower with isoflurane (2512 ppm. We also measured small concentrations of CO for sevoflurane and halothane. No significant temperature increases were detected with high CO productions. Conclusion All modern volatile anesthetics produce CO in desiccated sodalime. Sodalime temperature increase is a poor predictor of CO production.

  4. Convective Influence and Transport Pathways Controlling the Tropical Distribution of Carbon Monoxide at 100 Hpa

    Jensen, Eric; Bergman, John; Pfister, Leonard; Ueyama, Rei; Kinnison, Doug

    2014-01-01

    Trajectory calculations with convective influence diagnosed from geostationary-satellite cloud measurements are used to evaluate the relative importance of different Tropical Tropopause Layer (TTL) transport pathways for establishing the distribution of carbon monoxide (CO) at 100 hPa as observed by the Microwave Limb Sounder (MLS) on board the Aura satellite. Carbon monoxide is a useful tracer for investigating TTL transport and convective influence because the CO lifetime is comparable to the time require for slow ascent through the TTL (a couple of months). Offline calculations of TTL radiative heating are used to determine the vertical motion field. The simple trajectory model does a reasonable job of reproducing the MLS CO distributions during Boreal wintertime and summertime. The broad maximum in CO concentration over the Pacific is primarily a result of the strong radiative heating (indicating upward vertical motion) associated with the abundant TTL cirrus in this region. Sensitivity tests indicate that the distinct CO maximum in the Asian monsoon anticyclone is strongly impacted by extreme convective systems with detrainment of polluted air above 360 K potential temperature. The relative importance of different CO source regions will also be discussed.

  5. Comparison of measurement capability with 100 μmol/mol of carbon monoxide in nitrogen

    Lee, Jeongsoon; Lee, JinBok; Lim, Jeongsik; Tarhan, Tanıl; Liu, Hsin-Wang; Aggarwal, Shankar G.

    2018-01-01

    Carbon monoxide (CO) in nitrogen was one of the first types of gas mixtures used in an international key comparison. The comparison dates back to 1998 (CCQMK1a) [1]. Since then, many National Metrology Institutes (NMIs) have developed calibration and measurement capabilities (CMCs) for these mixtures. Recently, NMIs in the APMP region have actively participated in international comparisons to provide domestic services. At the 2013 APMP meeting, several NMIs requested a CO comparison to establish CO/N2 certification for industrial applications, which was to be coordinated by KRISS. Consequently, this comparison provides an opportunity for APMP regional NMIs to develop CO/N2 CMC claims. The goal of this supplementary comparison is to support CMC claim for carbon monoxide in the N2 range of 50–2000 μmol/mol. An extended range may be supported as described in the GAWG strategy for comparisons and CMC claims. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  6. Ambient carbon monoxide associated with alleviated respiratory inflammation in healthy young adults

    Zhao, Zhuohui; Chen, Renjie; Lin, Zhijing; Cai, Jing; Yang, Yingying; Yang, Dandan; Norback, Dan; Kan, Haidong

    2016-01-01

    There is increasing controversy on whether acute exposure to ambient carbon monoxide (CO) is hazardous on respiratory health. We therefore performed a longitudinal panel study to evaluate the acute effects of ambient CO on fractional exhaled nitric oxide (FeNO), a well-established biomarker of airway inflammation. We completed 4–6 rounds of health examinations among 75 healthy young adults during April to June in 2013 in Shanghai, China. We applied the linear mixed-effect model to investigate the short-term associations between CO and FeNO. CO exposure during 2–72 h preceding health tests was significantly associated with decreased FeNO levels. For example, an interquartile range increase (0.3 mg/m"3) of 2-h CO exposure corresponded to 10.6% decrease in FeNO. This association remained when controlling for the concomitant exposure to co-pollutants. This study provided support that short-term exposure to ambient CO might be related with reduced levels of FeNO, a biomarker of lower airway inflammation. - Highlights: • We completed 4–6 rounds of health examinations among 75 healthy young adults. • Short-term CO exposure was significantly associated with decreased FeNO levels. • The inverse association between CO and FeNO was robust controlling for co-pollutants. - Short-term exposure to ambient carbon monoxide may alleviate the respiratory inflammation.

  7. Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.

    Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R

    2005-11-01

    An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

  8. Carbon monoxide measurement by gas chromatography; Mesure du monoxyde de carbone par chromatographie en phase gazeuse

    Gros, V.; Sarda-Esteve, R.; Bonsang, B.; Ramonet, M.

    1998-09-01

    Although carbon monoxide (CO) is present in trace quantities in the atmosphere (0.1 ppm -or parts per million in volume- on average), the study of this gas is important. Indeed, its impact on human can be dangerous at high level of concentration on the hand and it constitutes one of the main precursor of ozone in presence of concentration on the one hand and it constitutes one of the main precursor of ozone in presence of other pollutants on the other hand. Finally, CO affects the levels of several important greenhouse gases, through its reaction with hydroxyl radicals (OH). CO is measured in the atmosphere since the mid 60's by various methods. Among them, gas chromatography has the advantage to combine a low detection limit with a high precision. This report details the improvements made on the measurement analyser which allowed to perform automatic CO measurements in remote areas with low mixing ratios of carbon monoxide. This report describes some quality tests and the results of various applications. (authors)

  9. Characteristics of autoignited laminar lifted flames in heated coflow jets of carbon monoxide/hydrogen mixtures

    Choi, Byungchul

    2012-06-01

    The characteristics of autoignited lifted flames in laminar jets of carbon monoxide/hydrogen fuels have been investigated experimentally in heated coflow air. In result, as the jet velocity increased, the blowoff was directly occurred from the nozzle-attached flame without experiencing a stabilized lifted flame, in the non-autoignited regime. In the autoignited regime, the autoignited lifted flame of carbon monoxide diluted by nitrogen was affected by the water vapor content in the compressed air oxidizer, as evidenced by the variation of the ignition delay time estimated by numerical calculation. In particular, in the autoignition regime at low temperatures with added hydrogen, the liftoff height of the autoignited lifted flames decreased and then increased as the jet velocity increased. Based on the mechanism in which the autoignited laminar lifted flame is stabilized by ignition delay time, the liftoff height can be influenced not only by the heat loss, but also by the preferential diffusion between momentum and mass diffusion in fuel jets during the autoignition process. © 2012 The Korean Society of Mechanical Engineers.

  10. Extension of the code COCOSYS to a dispersion code for smoke and carbon monoxide

    Sdouz, Gert; Mayrhofer, Robert

    2009-01-01

    The code COCOSYS (Containment Code SYStem) was developed by GRS in Germany to simulate processes and nuclear plant states during severe accidents in the containments of light water reactors. It contains several physical models, especially a module for aerosol behaviour. The goal of this work was to extend COCOSYS for applications in more general geometries mainly for complex public buildings. For the application in public buildings models for air condition systems and different boundary conditions according to different environments were developed. The principal application of the extended code COCOSYS is in the area of emergency situations especially in the simulation for carbon monoxide and smoke dispersion. After developing and implementing the new models several test calculations were performed to evaluate the functionality of the extended code. The comparison of the results with those of the original COCOSYS code showed no discrepancies. For the first realistic application several fire emergency scenarios in the Vienna General Hospital (AKH) were selected in agreement with the fire department of the hospital. One of the scenarios addresses the danger of carbon monoxide (CO) and smoke leaking into a fire protection section through a damaged fire protection flap. As a result of the dispersion simulation the CO-concentration in all of the rooms is obtained. Together with additional results as deposition and smoke dispersion the outcome of the simulation can be used for training. Among the next steps are the validation of the new models and the selection of critical scenarios. (author)

  11. Ratio of carbon monoxide to molecular hydrogen in interstellar dark clouds

    Dickman, R.L.; Rensselaer Polytechnic Institute; and The Ivan A. Getting Laboratories, The Aerospace Corporation)

    1978-01-01

    Carbon monoxide and molecular hydrogen column densities are compared at various locations within 38 interstellar dark clouds. CO column densities were obtained from radio observations of the J=1→0 transitions of the 12 C 16 O and 13 C 16 O isotopic species of the molecule. Corresponding H 2 column densities were inferred by means of visual extinctions derived from star counts, since it is argued that the standard gas-to-extinction ratio can be expected to remain valid in the clouds studied. For locations in the sources possessing line-of-sight visual extinctions in the approximate range 1.5 -2 ) = (5.0 +- 2.5) x 10 5 N 13 between molecular hydrogen and 13 CO LTE column densities. The carbon monoxide molecule can therefore be used as a quantitative ''tracer'' for the (directly unobservable) H 2 content of dark clouds. The above relationship implies that at least approx.12% of the gas-phase carbon in the clouds studied is in the form of CO, provided that the clouds are assumed to be chemically homogeneous. Langer's ion-molecule chemistry for dark clouds appears to agree well with the present work if the fractionation channel of Watson, Anicich, and Huntress is included

  12. Adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts

    Etherton, B.P.

    1980-01-01

    The adsorption and desorption of hydrogen and carbon monoxide were studied on alumina-supported iridium catalysts which were examined by a scanning transmission electron microscope (STEM). The metal particle size and number of particles per area of catalyst increased with increasing metal loading. The particles were approx. 10 A. in diameter, cubo-octahedral shaped, and approx. 80-90% disperse. The STEM electron beam caused negligible damage to the samples. Hydrogen adsorption measurements showed that the hydrogen-iridium atom ratio was 1.2:1-1.3:1 and increased with decreasing metal loading. Temperature-programed desorption showed four types of adsorbed hydrogen desorbing at -90/sup 0/C (I), 15/sup 0/C (IV), 115/sup 0/C (II), and 245/sup 0/C (III). Types II and IV desorb from single atom sites and Types I and III from multiple atom sites. Type I is in rapid equilibrium with the gas phase. All desorption processes appear to be first order. Carbon monoxide adsorbed nondissociatively at 25/sup 0/C with approx. 0.7:1 CO/Ir atom ratio. It adsorbed primarily in linear forms at low coverage, but a bridged form appeared at high coverage.

  13. The chest X-ray in pulmonary capillary haemorrhage: correlation with carbon monoxide uptake

    Bowley, N.B.; Hughes, J.M.B.; Steiner, R.E.

    1979-01-01

    Serial changes in carbon monoxide uptake (Ksub(CO) or Dsub(L)CO/VA) were used to monitor episodes of pulmonary capillary haemorrhage in Goodpasture's syndrome (13 cases), immune complex nephritis (three cases) and idiopathic haemosiderosis (one case). Air-space shadowing on the chest X-ray (on a scoring system 0 to 12) was assessed in the light of the changes of Ksub(CO). In 14 out of 27 episodes of bleeding, the rise and fall of Ksub(CO) was matched in time by the appearance and disappearance of air-space shadowing on the chest X-ray. In six episodes the chest X-ray remained normal despite a rise of Ksub(CO). In two cases air-space shadowing appeared up to 48 h after the rise of Ksub(CO). On five occasions chest X-ray abnormalities preceded the rise of Ksub(CO) but chest infection or fluid overload accounted for three of these. In cases with suspected pulmonary capillary haemorrhage, measurements of carbon monoxide uptake will provide additional information and will assist in the interpretation of the chest X-ray. (author)

  14. Retinal venous blood carbon monoxide response to bright light in male pigs: A preliminary study.

    Oren, Dan A; Duda, Magdalena; Kozioł, Katarzyna; Romerowicz-Misielak, Maria; Koziorowska, Anna; Sołek, Przemysław; Nowak, Sławomir; Kulpa, Magdalena; Koziorowski, Marek

    2017-03-01

    The physical mechanism by which light is absorbed in the eye and has antidepressant and energizing effects in Seasonal Affective Disorder and other forms of psychiatric major depression is of scientific interest. This study was designed to explore one specific aspect of a proposed humoral phototransduction mechanism, namely that carbon monoxide (CO) levels increase in retinal venous blood in response to bright light. Eleven mature male pigs approximately six months of age were kept for 7days in darkness and fasted for 12h prior to surgery. Following mild sedation, anesthesia was induced. Silastic catheters were inserted into the dorsal nasal vein through the angular vein of the eye to reach the ophthalmic sinus, from which venous blood outflowing from the eye area was collected. The animals were exposed to 5000lx of fluorescent-generated white light. CO levels in the blood were analyzed by gas chromatography before and after 80min of light exposure. At baseline, mean CO levels in the retinal venous blood were 0.43±0.05(SE)nmol/ml. After bright light, mean CO levels increased to 0.54±0.06nmol/ml (two-tailed t-test plight exposure raises carbon monoxide levels in ophthalmic venous blood. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Recent changes in carbon dioxide, carbon monoxide and methane and the implications for global climate change

    Novelli, P.C.; Conway, T.J.; Dlugokencky, E.J.; Tans, P.P. [National Oceanic and Atmospheric Administration, Boulder, CO (United States). Climate Monitoring and Diagnostics Lab.

    1995-01-01

    The article reviews figures for published data on recent changes of atmospheric levels of carbon dioxide, carbon monoxide and methane in terms of their sources and sinks. The largest source of CO{sub 2} is the combustion of fossil fuels, followed by emissions from deforestation and the oxidation of CO to CO{sub 2}. Carbon monoxide has an indirect influence on the earth`s radiative balance, as if levels of CO increase, levels of OH radicals decline which affects removal of other gases oxidised by this radical, notably CH{sub 4}. Major sources of CO are fossil fuel combustion, emissions from biomass, and oxidation of atmospheric CH{sub 4} and other non-methane hydrocarbons. The latest measurements suggest the depressed growth rates of CO{sub 2}, CO and CH{sub 4} have began to recover. Reasons for this are suggested. Future monitoring of atmospheric species in laboratories around the world, coupled with information on the isotopic signature of the trace gases, will improve our understanding of possible causes for trends in these gases. This will be invaluable in making policy decisions regarding future climate change. 34 refs., 4 figs.

  16. Computed tomography of delayed encephalopathy of acute carbon monoxide poisoning - correlation with clinical findings -

    Suh, Chang Hae; Chung, Sung Hoon; Choo, In Wook; Chang, Kee Hyun

    1986-01-01

    Cerebral computed tomography (CT) findings were described in twenty-six cases with the late sequelae of acute carbon monoxide poisoning and were computed with the neurological symptoms and signs. The CT findings include symmetrical periventricular white matter low density in five cases, globes pallidus low density in six cases, ventricular dilatation in seven cases, ventricular dilatation and sulci widening in three cases, and normal findings in ten cases. Only one case showed low densities in both periventricular white matter and globes pallidus. Late sequelae of the interval from of carbon monoxide poisoning were clinically categorized as cortical dysfunction, parkinsonian feature, and cerebella dysfunction. The severity of the clinical symptoms and signs of neurological sequelae is generally correlated with presence and multiplicity of abnormal brain CT findings. But of fourteen cases showing the parkinsonian feature, only five cases had low density of globes pallidus in brain CT. Another case showing small unilateral low density of globes pallidus had no parkinsonian feature but showed mild cortical dysfunction.

  17. Selected constituents in the smokes of U. S. commercial cigaretts: tar, nicotine, carbon monoxide and carbon dioxide

    Jenkins, R.A.; Quincy, R.B.; Guerin, M.R.

    1979-05-01

    One hundred twenty-one brands of United States commercial cigarettes were analyzed for their deliveries of tar, nicotine, carbon monoxide, and carbon dioxide under standard analytical smoking conditions. The sample included both filter and nonfilter cigarettes. Comparisons of carbon monoxide deliveries over the range of observed tar deliveries indicated a very high correlation between CO and tar for filter cigarettes, but nonfilter cigarettes tended to produce much less CO than would have been predicted from their tar deliveries. Comparison of ORNL nicotine values for specific brands with those determined by the Federal Trade Commission yield no statistically significant differences between laboratories. 4 figures, 6 tables.

  18. 40 CFR Table 5 to Subpart Bbbb of... - Model Rule-Carbon Monoxide Emission Limits for Existing Small Municipal Waste Combustion Units

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Model Rule-Carbon Monoxide Emission... BBBB of Part 60—Model Rule—Carbon Monoxide Emission Limits for Existing Small Municipal Waste... PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...

  19. Acute carbon monoxide intoxication : the relation between MR findings and clinical outcome

    Chang, Jin Bae; Jeong, Hae Woong; Kim, Ki Nam; Kim, Dong Wook; Kim, Chang Soo

    1999-01-01

    To analyse MR findings of various involving sites and the relation between such findings and clinical outcome, the authors retrospectively reviewed MR images of acute carbon monoxide intoxication. In 12 patients, MR images obtained from several hours to 12 days after acute carbon monoxide intoxication were reviewed. The images were analysed with regard to involved sites, symmetricity, signal intensity, and the presence or absence of hemorrhage, and the relationship between MR findings and clinical outcome; the presence of delayed encephalopathy was then determined. The globus pallidus(n=9), white matter(n=3), [centrum semiovale(n=2), periventricular white matter(n=1)] and gyrus(n=6) [inferior temporal gyrus(n=2), cingulate gyrus(n=1), precentral gyrus(n=1), hippocampal gyrus(n=1), parahippocampal gyrus(n=1)] were typically involved, and there was also involvenent of the corpus callosum(n=3), thalamus(n=2) and midbrain(n=2). All lesions of the globus pallidus, thalamus, midbrain and temporal lobe were bilaterally symmetric. In all these cases, subtle or prominent low signal intensity was seen on spin-echo T1WI, and high signal intensity on PDWI and T2WI. Some lesions of the globus pallidus(n=1), thalamus(n=1) and midbrain(n=1) were associated with hemorrhage, which occurred during the early subacute stage and was seen on high/low signal intensity T1/T2WI images. Acute cerebral(n=1) and cerebellar(n=1) infarctions were also seen. Cerebral white matter involvement correlated with poor clinical outcome, and in two cases, delayed encephalopathy developed. In these cases of acute carbon monoxide intoxication, the globus pallidus, white matter, cortex and hippocampus were frequently involved, and there was also involvement of various sites such as the corpus callosum, thalamus and midbrain. Lesions of the temporal lobe, thalamus and midbrain were bilaterally symmetric. The involvement of cerebral white matter and the presence of delayed encephalopathy can influence

  20. Monitoring of carbon monoxide in residences with bulk wood pellet storage in the Northeast United States.

    Rossner, Alan; Jordan, Carolyn E; Wake, Cameron; Soto-Garcia, Lydia

    2017-10-01

    The interest in biomass fuel is continuing to expand globally and in the northeastern United States as wood pellets are becoming a primary source of fuel for residential and small commercial systems. Wood pellets for boilers are often stored in basement storage rooms or large bag-type containers. Due to the enclosed nature of these storage areas, the atmosphere may exhibit increased levels of carbon monoxide. Serious accidents in Europe have been reported over the last decade in which high concentrations of carbon monoxide (CO) have been found in or near bulk pellet storage containers. The aim of this study was to characterize the CO concentrations in areas with indoor storage of bulk wood pellets. Data was obtained over approximately 7 months (December 2013 to June 2014) at 25 sites in New Hampshire and Massachusetts: 16 homes using wood pellet boilers with indoor pellet storage containers greater than or equal to 3 ton capacity; 4 homes with wood pellet heating systems with outdoor pellet storage; 4 homes using other heating fuels; and a university laboratory site. CO monitors were set up in homes to collect concentrations of CO in the immediate vicinity of wood pellet storage containers, and data were then compared to those of homes using fossil fuel systems. The homes monitored in this study provided a diverse set of housing stock spanning two and a half centuries of construction, with homes built from 1774 to 2013, representing a range of air exchange rates. The CO concentration data from each home was averaged hourly and then compared to a threshold of 9 ppm. While concentrations of CO were generally low for the homes studied, the need to properly design storage locations for pellets is and will remain a necessary component of wood pellet heating systems to minimize the risk of CO exposure. This paper is an assessment of carbon monoxide (CO) exposure from bulk wood pellet storage in homes in New Hampshire and Massachusetts. Understanding the CO concentrations