WorldWideScience

Sample records for hmpao-spect mit diamox-stimulation

  1. An evaluation of the cerebral hemodynamics in moyamoya disease with acetazolamide (Diamox) 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Qin-Yi, Gao; Kuwabara, Yasuo; Ichiya, Yuichi

    1994-01-01

    We studied the cerebral hemodynamics using Diamox 99m Tc-HMPAO SPECT in 9 patients with moyamoya disease, consisting of 4 children and 5 adults. Diamox 99m Tc-HMPO SPECT studies were performed by the double injection method. Hypoperfusion areas were scored by a visual inspection as follows: ++, definite positive; +, probable positive; -, negative. Diamox test was interpreted as positive when the score increased over one degree. In the resting state, 6 out of 9 patients showed definite or probable positive hypoperfusion, while all of 9 patients showed a similar finding after Diamox injection. The Diamox test was positive in 6 out of 9 patients. It was positive in all 3 patients who showed a negative hypoperfusion in the resting state. The regional cerebrovascular response to Diamox was most severely impaired in the frontal region. However, it was relatively well preserved in the cerebellum and thalamus according to the semiquantiative analysis. Thus, the Diamox HOPAO SPECT was considered to be useful in evaluating the hemodynamics in patients with moyamoya disease. (author)

  2. Pre and post operative evaluation of the perfusion reserve by acetazolamide 99mTc-HMPAO SPECT in patients with chronic occlusive cerebral arteries. A comparative study with PET

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Sasaki, Masayuki; Akashi, Yuko; Yoshida, Tsuyoshi; Fukumura, Toshimitsu; Masuda, Kouji; Fujii, Kiyotaka; Fukui, Masashi

    1994-01-01

    We studied the pre and post-operative perfusion reserve using Diamox 99m Tc-HMPAO SPECT in 7 patients with chronic occlusive cerebral arteries and then compared the results with PET. STAMCA anastomosis was performed on 5 patients, while a carotid endarterectomy was done on 2 patients. The cerebral blood flow, the vascular response to CO 2 or Diamox, the oxygen extraction fraction and transit time (CBV/CBF) were measured by PET. In the pre-operative state, the visual evaluations for hypoperfusion area at rest agreed in 5 out of 7 patients in HMPAO SPECT and PET studies. In the remaining 2 patients, hypoperfusion areas were only detected in the PET study. The pre-operative evaluation of perfusion reserve agreed in 2 patients. In the remaining 5 patients, 3 patients showed definite positive (++) in PET and positive (+) in HMPAO SPECT, and one patient showed positive (+) in PET and negative (-) in HMPAO SPECT. The post-operative change of hypoperfusion areas well agreed in HMPAO SPECT and PET studies. However, the change of perfusion reserve was underestimated in HMPAO SPECT compared with PET. In the semiquantitative and quantitative analyses, the count rate ratios (affected/unaffected side) in HMPAO SPECT were apparently higher than those of CBF in PET. The postoperative change of the count rate ratios in HMPAO SPECT were smaller than those of CBF in PET. There was no significant correlation between the change in the ratio of the HMPAO SPECT after the administration of Diamox and the oxygen extraction fraction, and it was thus thought to be impossible to predict the areas with an increased oxygen extraction fraction. Thus, Diamox HMPAO SPECT may underestimate the areas of hypoperfusion or decrease in perfusion reserve when compared with PET. We should consider these limitations in the evaluation of pre and post operative cerebral hemodynamics. (author)

  3. HMPAO-SPECT in cerebral seizures

    International Nuclear Information System (INIS)

    Gruenwald, F.; Bockisch, A.; Reichmann, K.; Ammari, B.; Hotze, A.; Biersack, H.J.; Durwen, H.; Buelau, P.; Elger, C.E.; Rohde, A.; Penin, H.

    1988-01-01

    In nine patients with suspected psychogenic seizures and in three patients with proven epileptic seizures HMPAO-SPECT was performed prior to and during seizure. In the patients with lateron-proven psychogenic seizures no, or only slight, changes of regional cerebral blood flow were found. Patients with proven epilepsy revealed partly normal findings interictally but during seizure a markedly increased circumscript blood flow was found in all patients. Even though PET is superior to SPECT with respect to spatial resolution, in the diagnosis of seizures HMPAO-SPECT has the advantage of enabling injection of the tracer during the seizure and the performance of the SPECT study subsequently. (orig.) [de

  4. Usefulness of change ratio map in 99mTc-HMPAO SPECT with acetazolamide enhancement

    International Nuclear Information System (INIS)

    Yamamoto, Naoyuki

    1996-01-01

    Although a sequential 99m Tc-HMPAO SPECT technique with Diamox test (seq-SPECT) is a simple and time-saving procedure to assess brain perfusion reserve, the influence of the first dose of the tracer on the second one is not negligible. Therefore, a subtraction of the rest-SPECT from the 2nd SPECT is widely-used. However, subtracted SPECT images not only need to be corrected for the injected dose and the radiochemical purity due to inherent instability of HMPAO but also are usually degraded in quality. This study was undertaken to resolve these problems utilizing a change ratio (CR) map. The CR map was obtained by dividing 2nd SPECT by rest-SPECT. Prior to subtraction, the 2nd SPECT was normalized with the ratio of the mean whole brain counts between both SPECTs. To validate CR map, 7 patients were studied with both seq-SPECT and 133 Xe inhalation CBF measurement (Xe-CBF). The right to left count ratio obtained from the ROIs placed on MCA territory of CR map correlated well with that from Xe-CBF (r=0.89, p<0.01). Fifty-three patients with stroke underwent the seq-SPECT which was compared with the cerebral angiography (CAG) and classified into 4 groups according to the CR map. In 25 patients, all of the rest-, the subtracted-SPECT and the CR map did not show any difference between the affected side and the contralateral normal side. Seven patients with normal rest-SPECT showed decreased subtracted-SPECT counts and CR on the affected side. Three of them showed more than 75% stenosis on CAG. Four patients with the decreased counts both at the rest-and the subtracted-SPECT revealed no difference on the CR map suggesting the matched decrease of both blood flow and metabolism in the affected side. In conclusion, the CR map was a simple and useful method to evaluate the brain perfusion reserve with the seq-SPECT. (author)

  5. 99mTc-HMPAO Brain SPECT in Patients with Post-Traumatic Organic Mental Disorder

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Lee, Dong Jin; Shong, Min Ho; Kang, Min Hee; Ghi, Ick Sung; Shin, Young Tai; Ro, Heung Kyu

    1994-01-01

    It is well known that 99m Tc-HMPAO brain SPECT can reflect the functional lesions better than X-ray computerized tomography(CT) and magnetic resonance imaging(MRI) in the cerebral disorders. In order to evaluate the clinical utilities of 99m Tc-HMPAO brain SPECT in patients with post-traumatic chronic organic mental disorder(OMD). We included 28 patients diagnosed as OMD in department of psychiatry after traumatic head injury. And we compared the results of 99m Tc-HMPAO SPECT with those of MRI, EEG and MINI mental status examination(MMSE). The results were as follows 1) All patients diagnosed as OMD showed diffuse or focal decreased cerebral perfusion on 99m Tc-HMPAO SPECT. 2) Most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT showing normal brain MRI result was also decreased both frontal perfusion. 3) Eight of 28 patients showed focal brain MRI lesions(4 small frontal hygroma, 3 small cerebral infarction and 1 cerebellar encephalomalacia) which were not detected in brain 99m Tc-HMPAO SPECT. 4) The patients showing less than 20 points on MMSE disclosed abnormal results of EEG more frequently than those disclosing more than 20 points. In conclusion, we think that 99m Tc-HMPAO brain SPECT is sensitive method to detect functional lesions of the brains in patients with chronic post-traumatic organic mental disorder.

  6. HM-PAO SPECT in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Cordes, M.; Rummeny, E.; Reissmann, M.; Fox, K.; Panitz, N.; Pfannenstiel, P.

    1987-01-01

    Single photon emission computed tomography (SPECT) after injection of 99m-Tc-HM-PAO was used to examine 34 patients whose clinical findings could not exclude a cerebrovascular disease. In all patients an X-ray computed tomography examination was inconclusive for the clinical-neurological findings. The regional cerebral bloodflow was pathologically disturbed in 10 of 34 patients in the HM-PAO SPECT examination. The detection of the regional cerebral bloodflow with HM-PAO SPECT is helpful in the diagnosis of cerebrovascular disease. (orig.) [de

  7. 99mTc-HMPAO SPECT in pediatric patients with neurological disorders

    International Nuclear Information System (INIS)

    Yamaoka, Mitsuko

    1994-01-01

    In 125 pediatric patients with suspected brain diseases, EEG, CT and MRI findings were compared with those obtained with single photon emission computed tomography (SPECT) of the brain using Tc-99m-d, 1-hexamethyl-propylene amine oxime ( 99m Tc-HMPAO), to determine the usefulness of SPECT as an adjunct to EEG, CT and MRI in this age group. The incidences of abnormal finding in the 125 patients were 53.6, 75.2, 60.6 and 51.4% using 99m Tc-HMPAO SPECT, EEG, CT and MRI respectively. In localization-related epilepsy and cerebrovascular diseases, the incidence of abnormality was higher with 99m Tc-HMPAO SPECT than with either CT or MRI. There was a tendency for mean age to be higher and mean IQ or DG lower in patients with more extensive abnormality in comparison to those who had normal or only focally abnormal SPECT findings. Nevertheless, some patients showed focal hypofusion in the frontal or occipital area without significant mental retardation. Epileptic foci detected by EEG corresponded to defects found using 99m Tc-HMPAO SPECT in 34.8% of the symptomatic localization-related epileptic patients. Pathological lesions detected by CT or MRI corresponded with SPECT findings in 48.1% of patients. Furthermore, the incidence of abnormal findings on SPECT was 30% in patients in whom CT or MRI was normal. Epileptic foci detected by EEG did not correspond well with the area of focal hyperfusion found on SPECT. Focal hyperfusion may sometimes occur even in the interictal period or postictal period in childhood seizure disorders. In conclusion, 99m Tc-HMPAO SPECT revealed abnormal findings at a moderate incidence in neuropediatric patients. Correlations with EEG, CT and MRI findings as well as assessment of clinical signs, including the investigation of epileptic foci, are essential for adequate interpretation of brain functions. (author)

  8. Presurgical evaluation of cerebral perfusion reserve in patients for cardiovascular surgery using {sup 99m}Tc-ECD SPECT with diamox enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kaname; Nakashima, Hiromichi; Tanaka, Kuniyoshi; Kitano, Tokio; Murashima, Shuichi; Takeda, Kan; Yuasa, Hiroshi; Yada, Isao; Nakagawa, Tsuyoshi [Mie Univ., Tsu (Japan). School of Medicine

    1996-03-01

    Cerebrovascular stroke is one of the major complications in cardiovascular surgery with cardiopulmonary bypass. The purpose of this study was to evaluate the usefulness of preoperative {sup 99m}Tc-ethyl cysteinate dimer (ECD) SPECT and acetazolamide (diamox) enhancement to predict neurological complications in cardiovascular surgery. Eighteen patients with coronary disease, valvular disease or aortic aneurysm were studied before the operations. Regional cerebral blood flow and perfusion reserve were evaluated using ECD SPECT before and after the intravenous administration of diamox (1 g). Three cases with moderate to severe baseline abnormalities and poor perfusion reserve had cerebral infarction postoperatively. Twelve cases with good to fair perfusion reserve had no neurological complication. Three cases having poor perfusion reserve had the operations with more intensive brain protection, in which higher perfusion pressure to the brain was maintained during cardiopulmonary bypass, and no neurological complication was observed. In conclusion, patients who have moderately or markedly abnormal baseline flow with poor perfusion reserve may have some risk of neurological complications in cardiovascular surgery. ECD SPECT with diamox enhancement may give information useful for selection of operation procedures. (author).

  9. Quantitative evaluation of regional cerebral blood flow by visual stimulation in 99mTc-HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Juh, R. H.; Suh, T. S.; Chung, Y. A.

    2002-01-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of 99mTc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99mTc- HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50±5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann

  10. Quantitative evaluation of regional cerebral blood flow by visual stimulation in 99mTc- HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Juh, Ra Hyeong; Suh, Tae Suk; Kwark, Chul Eun; Choe, Bo Young; Lee, Hyoung Koo; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo

    2002-01-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of '9 9m Tc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99m Tc-HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map(SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50±5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann

  11. Topodiagnosis in Creutzfeldt-Jakob disease by HMPAO-SPECT. Topodiagnostik der Creutzfeldt-Jakobschen Krankheit durch HMPAO-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Heye, N. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Farahati, J. (Klinik und Poliklinik fuer Nuklearmedizin, Essen Univ. (Gesamthochschule) (Germany)); Heinz, A. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Buettner, T. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Przuntek, H. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Reiners, C. (Klinik und Poliklinik fuer Nuklearmedizin, Essen Univ. (Gesamthochschule) (Germany))

    1993-02-01

    A 80-year old female presented with an early stage of Creutzfeldt-Jakob disease with clinical, neurophysiological and neuropathological findings suggesting a focal involvement of the brain. HMPAO SPECT disclosed asymmetries of regional cerebral perfusion, thus suggesting that it may be a further diagnostic instrument in this disease. (orig.)

  12. Quantitative evaluation of regional cerebral blood flow by visual stimulation in {sup 99m}Tc- HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Juh, Ra Hyeong; Suh, Tae Suk; Kwark, Chul Eun; Choe, Bo Young; Lee, Hyoung Koo; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo [College of Medicine, The Catholic Univ. of Seoul, Seoul (Korea, Republic of)

    2002-06-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of '9{sup 9m}Tc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and {sup 99m}Tc-HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map(SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50{+-}5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

  13. Quantitative evaluation of regional cerebral blood flow by visual stimulation in {sup 99m}Tc-HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R. H.; Suh, T. S.; Chung, Y. A. [The Catholic Univ., of Korea, Seoul (Korea, Republic of)

    2002-07-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of 99mTc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99mTc- HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50{+-}5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

  14. 99mTc HM-PAO brain perfusion SPECT in brain death

    International Nuclear Information System (INIS)

    Bonetti, M.G.; Ciritella, P.; Valle, G.; Perrone, E.

    1995-01-01

    We have easily carried out and interpreted 99m Tc HM-PAO SPECT in a consecutive series of 40 comatose patients with brain damage, without discontinuing therapy. Brain death was diagnosed in 7 patients, by recognising absence of brain perfusion, as shown by no intracranial radionuclide uptake. In patients in whom perfusion was seen on brain scans, HM-PAO SPECT improved assessment of the extent of injury, which in general was larger than suggested by CT. (orig.)

  15. 123I-iomazenil brain receptor SPECT in focal epilepsy. In comparison with 99mTc-HMPAO brain SPECT, MRI and Video/EEG monitoring

    International Nuclear Information System (INIS)

    Xu Hao; Wang Tongge; Huang Li; Michael Cordes

    1998-01-01

    Purpose: To evaluate the clinical value of 123 I-Iomazenil brain receptor SPECT in diagnosis of focal epilepsy in comparison with 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Methods 123 I-Iomazenil brain receptor SPECT was performed on 40 patients with focal epilepsy. The results were compared with those obtained by 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Results: In 40 patients, the sensitivity of Video/EEG monitoring for localization of epileptogenic area was 95% (38/40). The sensitivity of 123 I-iomazenil brain receptor SPECT, 99m Tc-HMPAO brain SPECT and MRI for localization of epileptogenic area compared with Video/EEG monitoring ('gold standard') was 65.8%(25/38), 55.3%(21/38) and 47.4%(18/38), respectively. The localization of epileptogenic area with 123 I-Iomazenil brain receptor SPECT was in concordance with Video/EEG monitoring in 20 patients, 99m Tc-HMPAO brain SPECT in 15 patients and MRI in 16 patients, respectively. The sensitivity of 123 I-Iomazenil brain receptor SPECT combined with MRI for localization of epileptogenic area was 84.2%(32/38). Conclusions: 123 I-Iomazenil brain receptor SPECT is a useful method in detecting and localizing epileptogenic area. The combination of 123 I-Iomazenil brain receptor SPECT and MRI has a high sensitivity for detecting epileptogenic area

  16. SPECT with [99mTc]-d,l-hexamethyl-propylene amine oxime (HM-PAO) compared with regional cerebral blood flow measured by PET

    DEFF Research Database (Denmark)

    Yonekura, Y; Nishizawa, S; Mukai, Thomas Søgaard

    1988-01-01

    In order to validate the use of technetium-99m-d,l-hexamethylpropyleneamine oxime (HM-PAO) as a flow tracer, a total of 21 cases were studied with single photon emission computerized tomography (SPECT), and compared to regional cerebral blood flow (rCBF) measured by position emission tomography...... (PET) using the oxygen-15 CO2 inhalation technique. Although HM-PAO SPECT and rCBF PET images showed a similar distribution pattern the HM-PAO SPECT image showed less contrast between high and low activity flow regions than the rCBF image and a nonlinear relationship between HM-PAO activity and r......CBF was shown. Based on the assumption of flow-dependent backdiffusion of HM-PAO from the brain, we applied a "linearization algorithm" to correct the HM-PAO SPECT images. The corrected HM-PAO SPECT images revealed a good linear correlation with rCBF (r = 0.901, p less than 0.001). The results indicated HM-PAO...

  17. 99mTc-HMPAO SPECT in brain death

    International Nuclear Information System (INIS)

    Tsuchida, Tatsuro; Sadato, Norihiro; Nishizawa, Sadahiko

    1993-01-01

    Brain single photon emission computed tomography (SPECT) with 99m Tc-d,l-hexamethyl-propyleneamine oxime (HMPAO) was performed twice in a 78-year-old man clinically diagnosed as brain death according to the standard criteria of the Japanese Ministry of Welfare. The first brain SPECT demonstrated the tracer accumulation in the brain, indicating preserved cerebral blood flow. The second brain SPECT performed 3 days later revealed cessation of the blood flow. In patients with preserved cerebral blood flow, the diagnosis of brain death cannot be made, even if they meet the existing criteria, because previous report noted the recovery in some of those patients. Brain perfusion SPECT plays an important role as a confirmatory test for the diagnosis of brain death. (author)

  18. Topodiagnosis in Creutzfeldt-Jakob disease by HMPAO-SPECT

    International Nuclear Information System (INIS)

    Heye, N.; Farahati, J.; Heinz, A.; Buettner, T.; Przuntek, H.; Reiners, C.

    1993-01-01

    A 80-year old female presented with an early stage of Creutzfeldt-Jakob disease with clinical, neurophysiological and neuropathological findings suggesting a focal involvement of the brain. HMPAO SPECT disclosed asymmetries of regional cerebral perfusion, thus suggesting that it may be a further diagnostic instrument in this disease. (orig.) [de

  19. Improvement of Cerebral Hypoperfusion with Levothyroxine Therapy in Hashimoto's Encephalopathy Demonstrated by 99mTc-HMPAO-SPECT

    Science.gov (United States)

    Schnedl, Wolfgang J.; Mirzaei, Siroos; Wallner-Liebmann, Sandra J.; Tafeit, Erwin; Mangge, Harald; Krause, Robert; Lipp, Rainer W.

    2013-01-01

    Background Hashimoto's encephalopathy (HE) is a rare immune-mediated encephalopathy associated with autoimmune Hashimoto's thyroiditis. Objectives and Methods We report on a patient with HE and significant clinical improvement correlating with an increase in cerebral blood flow demonstrated by hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). HMPAO-SPECT was performed with 740 MBq of technetium-99m-HMPAO. To demonstrate the improvement in regional cerebral blood flow, individual regions of interest were drawn around visually diminished HMPAO uptake, the lesion to reference region ratio was calculated and transverse section images and semi-quantitative measurements were performed. Results We show a 5-year follow-up with significant clinical improvement, a 10-fold reduction in autoantibodies to thyroid peroxidase and an approximately 20% improvement in cerebral blood flow with HMPAO-SPECT. Conclusion Adequate levothyroxine treatment achieving and maintaining euthyroidism should be considered as therapy to lower autoantibodies and improve clinical outcome in patients with Hashimoto's thyroiditis and encephalopathy. PMID:24783049

  20. Presentation of regional cerebral blood flow in amphetamine abusers by 99Tcm-HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Kao, C.H.; Wang, S.J.; Yeh, S.H.

    1994-01-01

    The aim of this study was to describe the effectiveness of 99 Tc m -hexamethylpropyleneamine oxime ( 99 Tc m -HMPAO) brain single photon emission computed tomography (SPECT) in the assessment of the regional cerebral blood flow (rCBF) in amphetamine abusers. Twenty-one amphetamine abusers were included and 99 Tc m -HMPAO brain SPECT performed to evaluate rCBF. The drug-using periods ranged from 1 month to several years. The demonstrated neuropsychogenic symptoms and signs of the abusers were from normal presentation to various neurologic complications. The brain SPECT scans were interpreted visually as either normal or abnormal. The degree of abnormality was classified into mild or severe. The results revealed that (a) most SPECT studies in abusers show small defects (95%, 20/21 cases); 71% (15/21) of cases revealed multiple defects over both hemispheres (classified as severe); 24% (5/21) of the cases had focal defects (classified as mild); and only one case (5%, 1/21) demonstrated a normal SPECT finding; (b) the degree of abnormality on SPECT scans was not related to the dose and duration of drug use or the severity of the neuropsychiatric symptoms and signs. In conclusion, 99 Tc m -HMPAO brain SPECT is a sensitive but not specific test for neuropsychogenic abnormalities associated with amphetamine abuse. (Author)

  1. Comparison of Tc-99m HM-PAO SPECT brain scan and x-ray CT in the detection of brain metastases

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.M.; Sadek, S.; Sahwell, A.; Kubasek, H.; El-Sayed, M.; Ziada, G.; Mobarak, L.; Al-Huda, F.; Omar, Y.T.

    1986-01-01

    Tc-99m HM-PAO imaging was compared with x-ray CT in 14 patients with known or suspected brain metastases. Both studies were done within 3 days of each other. Static and single photon emission CT (SPECT) images were acquired after intravenous injection of 13 mCi of Tc-99m HM-PAO. All 14 patients underwent static and SPECT Tc-99m HM-PAO imaging and x-ray CT. Studies were positive in 7, 12, and 10 patients, respectively, by static, SPECT, and x-ray CT imaging, and negative in 7, 2, and 2. The number of lesions identified was 0 (static imaging), 32 (SPECT), and 26(x-ray CT). There were no ''suspicious'' studies by any modality. This study indicates that Tc-99m HM-PAO SPECT cerebral blood flow imaging is more sensitive than x-ray CT for detecting brain metastases, that biplane imaging is not sensitive and SPECT is essential, and that for Tc-99m HM-PAO SPECT brain imaging to regain its importance with respect to x-ray CT, acquisition time must be 10 minutes or less and determination of percentage brain uptake of the injected dose, and of regional distribution, is necessary

  2. Differential diagnosis of regional cerebral hyperfixation of TC-99m HMPAO on SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shirazi, P.; Konopka, L.; Crayton, J.W. [Loyola Univ. Medical Center, Maywood, IL (United States)] [and others

    1994-05-01

    Accurate diagnostic evaluation of patients with neurologic and neuropsychiatric disease is important because early treatment may halt disease progression and prevent impairment or disability. Cerebral hyperfixation of HMPAO has been ascribed to luxury perfusion following ischemic infarction. The present study sought to identify other conditions that also display radiotracer hyperfixation in order to develop a differential diagnosis of this finding on SPECT imaging. Two hundred fifty (n=250) successive cerebral SPECT images were reviewed for evidence of HMPAO hyperfixation. Hyperfixation was defined as enhanced focal perfusion surrounded by a zone of diminished or normal cerebral perfusion. All patients were scanned after intravenous injection of 25 mCi Tc-99m HMPAO. Volume-rendered and oblique images were obtained with a Trionix triple-head SPECT system using ultra high resolution fan beam collimators. Thirteen (13/250; 5%) of the patients exhibited regions of HMPAO hyperfixation. CT or MRI abnormalities were detected in 6/13 cases. Clinical diagnoses in these patients included intractable psychosis, post-traumatic stress disorder, alcohol and narcotic dependence, major depression, acute closed-head trauma, hypothyroidism, as well as subacute ischemic infarction. A wide variety of conditions may be associated with cerebral hyperfixation of HMPAO. These conditions include neurologic and psychiatric diagnoses, and extend the consideration of hyperfixation beyond ischemic infarction. Consequently, a differential diagnosis of HMPAO hyperfixation may be broader than originally considered, and this may suggest a fundamental role for local cerebral hyperperfusion. Elucidation of the fundamental mechanism(s) for cerebral hyperperfusion requires further investigation.

  3. Value of Tc-99m HMPAO SPECT imaging in patients with TIA or acute stroke and normal CT

    International Nuclear Information System (INIS)

    Koster, K.; Brass, L.M.; Hoffer, P.B.; Gottschalk, A.; Smith, E.O.; Rehm, P.K.

    1988-01-01

    To determine the value of Tc-99m HMPAO single photon emission CT (SPECT) imaging, 51 patients with transient, acute, or chronic cerebrovascular disease were studied. Seventeen patients presented with recent transient ischemic attack (TIA) or acute stroke and underwent SPECT imaging and CT within 72 hours of presentation. SPECT image interpretation was independent of clinical history and CT findings. Four patients with acute stroke and eight patients with TIA had normal CT findings. All patients with acute stroke (three nonlacunar, one lacunar infarct) and three of eight patients with TIA also showed perfusion abnormalities on Tc-99m HMPAO scans. Thus, Tc-99m HMPAO SPECT may be useful in the early diagnosis and subtype determination of acute stroke and in the evaluation of TIA

  4. A new method for brain functional study using Tc-99m HMPAO SPECT

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Ohtake, Tohru; Watanabe, Toshiaki; Iio, Masahiro

    1989-01-01

    The distribution of 99m Tc-HMPAO in brain is in proportion to regional cerebral blood flow (rCBF) and can be interpreted as functional mapping. To evaluate local changes in CBF during neuropsychological testing, we developed a new subtraction method using HMPAO and SPECT. With patients resting, 15 mCi of HMPAO was injected and the first acquisition was performed, lasting a total of 10 minutes. Soon after the end of the first scan, patients were requested to undergo Buschke's memory test or to repeat words or numbers (repetition test). During the task, an additional 15 mCi of HMPAO was injected using the same position as in the first scan, and a second acquisition was started. A functional image was made by subtracting the image in the first scan from that in the second. In two patients with transient global amnesia and two normal controls, Buschke's memory test was performed in combination with SPECT. A relative increase in activity was seen in the thalamus, subthalamic area, hippocampus, and some cortial areas, apparently reflecting local functional change induced by the memory task. In two patients with moderate Alzheimer's disease with severe memory loss, no increase was detected in these areas. In one patient with aphasia, the repetition test with SPECT was correlated with the WADA test and dichotic listening test, and good agreement was obtained. In conclusion, our new SPECT technique is useful in detecting alterations in rCBF during mental activity and can be applied to neurophysiological studies. (author)

  5. A new method for brain functional study using Tc-99m HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Ohtake, Tohru; Watanabe, Toshiaki; Iio, Masahiro (Tokyo Univ. (Japan). Faculty of Medicine)

    1989-04-01

    The distribution of {sup 99m}Tc-HMPAO in brain is in proportion to regional cerebral blood flow (rCBF) and can be interpreted as functional mapping. To evaluate local changes in CBF during neuropsychological testing, we developed a new subtraction method using HMPAO and SPECT. With patients resting, 15 mCi of HMPAO was injected and the first acquisition was performed, lasting a total of 10 minutes. Soon after the end of the first scan, patients were requested to undergo Buschke's memory test or to repeat words or numbers (repetition test). During the task, an additional 15 mCi of HMPAO was injected using the same position as in the first scan, and a second acquisition was started. A functional image was made by subtracting the image in the first scan from that in the second. In two patients with transient global amnesia and two normal controls, Buschke's memory test was performed in combination with SPECT. A relative increase in activity was seen in the thalamus, subthalamic area, hippocampus, and some cortial areas, apparently reflecting local functional change induced by the memory task. In two patients with moderate Alzheimer's disease with severe memory loss, no increase was detected in these areas. In one patient with aphasia, the repetition test with SPECT was correlated with the WADA test and dichotic listening test, and good agreement was obtained. In conclusion, our new SPECT technique is useful in detecting alterations in rCBF during mental activity and can be applied to neurophysiological studies. (author).

  6. Preliminary results of SPECT studies with 99mTc-HMPAO in endogenous psychoses

    International Nuclear Information System (INIS)

    Wilhelm, K.R.; Georgi, P.; Schroeder, J.; Henningsen, H.; Sauer, H.

    1989-01-01

    18 psychopharmacologically treated patients (7 schizophrenics, 5 schizoaffectives, 6 depressives) were studied using 99m Tc-HMPAO-SPECT of the brain. The regional cerebral blood flow was measured in three transversal sections (infra-/supraventricular, ventricular) within 6 regions of interest (ROI) respectively (one frontal, one parietal and one occipital in each hemisphere). Corresponding ROIs of the same section in each hemisphere were compared. In the schizophrenics there was a significantly reduced perfusion in the left frontal region of the infraventricular and ventricular section (p 99m Tc-HMPAO-SPECT may be helpful in finding cerebral abnormalities in endogenous psychoses. (orig.) [de

  7. HMPAO-SPECT in dementia of the Alzheimer type and major depression with memory impairment. HMPAO-SPECT bei Demenz vom Alzheimer-Typ und Major Depression mit mnestischen Stoerungen

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, F [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Horn, R [Bonn Univ., Psychiatrische Klinik (Germany); Rieker, O [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Klemm, E [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Menzel, C [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Moeller, H J [Bonn Univ., Psychiatrische Klinik (Germany); Biersack, H J [Bonn Univ., Klinik fuer Nuklearmedizin (Germany)

    1993-06-01

    The aim of the present study was to see whether HMPAO-SPECT may contribute to the differentiation between dementia of the Alzheimer type (DAT) and major depression (MD). The results in 77 patients with memory impairment were evaluated. 48 patients suffered from DAT and 29 from MD. Initially, the defects in SPECT imaging were attributed to a cerebral region and the degree of decrease was evaluated (-1/-2/-3). Thereafter, the results were classified by 7 categories. In some of these categories an accumulation of cases of either DAT or MD was found. 35% of the patients suffering from DAT had bilateral defects with distinct (>-1) parietal/parietotemporal hypoperfusions, but no patient with MD showed this perfusion pattern. 62% of the patients with MD had unilateral defects but only 31% of the patients with DAT. The present study demonstrates that only 35% of all patients suffering from DAT show a perfusion pattern, thought earlier as ''pathognomonic'' for this disease. This perfusion pattern - if it exists - may be used as a safe criterion to exclude MD. Beyond that no clearcut (''specific'') perfusion pattern may be recognized but unilateral defects point to MD. (orig.)

  8. 99mTc-HMPAO Regional Cerebral Blood Flow SPECT in Transient Ischemic Attacks

    International Nuclear Information System (INIS)

    Ahn, Myeong Im; Park, Young Ha; Lee, Sung Yong; Chung, Soo Kyo; Kim, Jong Woo; Bahk, Yong Whee

    1989-01-01

    Transient ischemic attacks (TJAs) is a syndrome resulting from brain ischemia lasting less than 24 hours. The mechanisms of TIAs may be similar to those of cerebral embolism and thrombosis, and thus TIAs may be followed by cerebral infarction. Despite the availability of CT scanning, the diagnosis and management of TIAs continue to be difficult. Recently SPECT has been advocated as a diagnostic imaging modality. We performed 99m Tc-HMPAO regional cerebral blood flow (rCRF) SPECT in 24 patients with the clinical diagnosis of TIAs to assess its ability to detect early changes of rCBF, and determine the diagnostic value. Ten men and fourteen women with an average of 51 years (range; 27-74 years) were included. All but 8 patients had normal brain CT prior to SPECT. The two patients had moderate degree of brain atrophy and the 6 patients nonspecific calcifications. Eighteen of the 24 patients had abnormal 99m Tc-HMPAO rCBF SPECT. Fifteen had unilateral involvement and the other three had bilateral involvements. Seventy-five percents of the defects were found in the left cerebral hemisphere. According to the distribution of the lesions (total number: 34 lesions), fourteen were in the parietal, eight in the temporal, and the remainders were elsewhere. 99m Tc-HMPAO rCHF SPECT is sensitive in detecting rCRF abnormalities in patients with TIAs, and represent the most accurate diagnostic tool available in the diagnosis of TIAs

  9. Tc-99m-HMPAO neuroactivation SPECT in patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Klissarova, A.; Tranulov, G.; Deleva, D.; Kaprelyan, A.; Tjaneva, M.

    2002-01-01

    Aim: Tc-99m-HMPAO-SPECT detects the hypoperfusion areas in the temporal and parietal lobes as well as in the frontal lobes in the advanced stages of Alzheimer's disease. These hypoperfusion areas correlate with decreased glucose metabolism and oxygen utilization. The aim of the study was to establish the neuroactivation effect on the regional cerebral blood flow and on the hypoperfusion areas detected by means of Tc-99m-HMPAO-SPECT in patients with Alzheimer's disease. Materials and methods: Subject to the study were 22 patients with Alzheimer's disease divided into two groups according to the results from the neuropsychological tests as follows: Ist group - 10 patients with slight cognitive disturbances; IInd group - 12 patients with prominent cognitive impairment. All patients underwent Brain-SPECT after I.V. injection of 740 MBq Tc-99m-HMPAO at rest and during neuroactivation by labyrinth task on the next day. Regional blood flow was detected by means of the hypoperfusion indices calculated as follows: hypoperfusion areas in the temporal lobe and /or the parietal lobe to the referent areas of the cerebellum. The regional blood flow decrease in hypoperfusion areas was calculated in per cent. Results: Hypoperfusion areas were detected at rest in 5 patients from the Ist group and in all patients from the IInd group. A decrease of the regional cerebral blood flow by 5-10% was established after neuroactivation in all the seventeen patients with hypoperfusion areas at rest. After neuroactivation three of the patients with normal regional cerebral perfusion at rest revealed hypoperfusion areas in the posterior part of the parietal lobe and the temporo-parietal areas. The remaining two patients showed normal regional cerebral blood flow at rest and during neuroactivation. Conclusion: Neuroactivation reduces the regional cerebral blood flow in hypoperfusion areas at rest in patients with Alzheimer's disease. Neuroactivation Tc-99m-HMPAO SPECT is useful for the detection

  10. Evaluation of cerebral vasoreactivity by SPECT and transcranial doppler sonography using the acetazolamide test

    Energy Technology Data Exchange (ETDEWEB)

    Pavics, L. [Dept. of Nuclear Medicine, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Gruenwald, F. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin; Barzo, P. [Dept. of Neurosurgery, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Ambrus, E. [Dept. of Nuclear Medicine, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Menzel, C. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin; Schomburg, A. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin; Borda, L. [Dept. of Neurosurgery, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Mate, E. [Laszlo Kalmar Kibernetic Lab., Attila Jozsef Univ., Szeged (Hungary); Bodosi, M. [Dept. of Neurosurgery, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Csernay, L. [Dept. of Nuclear Medicine, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Biersack, H.J. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin

    1994-12-01

    rCBF SPECT with {sup 99m}Tc-HMPAO was performed prospectively in 29 patients (3 controls and 26 stroke patients) as well as TCD studies in 20 patients (3 controls and 17 stroke patients) before and after 1 g i.v. acetazolamide. The sensitivity of rCBF SPECT increased from 62% to 77% after acetazolamide provocation in stroke patients. In patients with a reversible neurological deficit, the sensitivity under resting conditions was 50% which increased to 71%, while in cases with a permanent deficit it increased from 75% to 83%. In the evaluation of the cerebrovascular reserve capacity the results of rCBF SPECT and TCD coincided in 91% of the hemispheres. The correlation was statistically significant. (orig.) [Deutsch] Bei 29 Patienten (3 Kontrollpersonen, 26 Patienten mit zerebrovaskulaerer Erkrankung) wurde prospektiv die Hirn-SPECT mit {sup 99m}TC-HMPAO und bei 20 Patienten (3 Kontrollpersonen, 17 Patienten mit ZVK) die transkranielle Dopplersonographie (TCD) vor und nach i.v. Gabe von Azetazolamid durchgefuehrt. Die Sensitivitaet der Hirn-SPECT erhoehte sich mit Azetazolamid von 62% auf 77%. Bei Patienten mit reversiblem neurologischem Defizit wurde eine Verbesserung von 50% auf 71%, bei Patienten mit persistierendem Defizit von 75% auf 83% beobachtet. Die Ergebnisse der Hirn-SPECT und der TCD stimmten in der Beurteilung der zerebrovaskulaeren Reservekapazitaet in 91% der Hemisphaeren ueberein. Die Korrelation zwischen den beiden Methoden war statistisch signifikant. (orig.)

  11. 99mTc-HMPAO SPECT thalamic blood flow study in migraine

    International Nuclear Information System (INIS)

    Zhang Zhijian; Steiner, T.J.

    1995-01-01

    The changes of blood flow in the thalamic of migraineurs by 99m Tc-HMPAO SPECT imaging are investigated. 60 cases with migraine were performed by Novo 810 high-resolution SPECT 30 minutes after injection of 99m Tc-HMPAO. The quantitative analysis of SPECT data was based on the irregular ROI% uptake normalized to total slice method. There were significantly increased mean % uptake values in migraine with aura (259.1 +-17.1), and more significantly in those who experienced hemisensory symptoms and hemiparesis during aura (263.8 +- 17.2), compared to that of migraine without aura (249.1 +- 14.9), but there were not statistically significant difference between migraine with only visual disturbance during aura (255.1 +- 16.4) and without aura. The possible explanations for the increased mean % uptake values in migraineurs who experienced hemisensory symptoms and hemiparesis during aura are: (1) the reactive postischemic hyperemia. (2) excepting thalamus, the regional blood flow was decreased. (3) the secondary phenomenon to the various neurogenic and chemical stimuli

  12. Brain perfusion SPECT imaging before and during the acetazolamide test using sup 99m Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Higashi, Sotaro; Kinuya, Keiko; Tsuji, Shiro; Sumiya, Hisashi; Hisada, Kinichi; Yamashita, Junkoh (Kanazawa Univ. (Japan). School of Medicine)

    1990-05-01

    A new method using brain perfusion {sup 99m}Tc-HMPAO SPECT imaging was developed for evaluating cerebral perfusion reserve by the acetazolamide test with a short period. The first SPECT study was carried out for 13.5 min to obtain SPECT images at the resting state after 3 min postinjection of 555 MBq (15 mCi) of {sup 99m}Tc-HMPAO. At the same time as the start of the first SPECT study, 1 g of acetazolamide was intravenously injected. Immediately after the stop of the 1st SPECT study, 925 MBq (25 mCi) of {sup 99m}Tc-HMPAO from the same vial as in the first study was additionally injected. Three minutes later the second SPECT study was carried out for 10 min. After reconstruction the tomographic images in the first study were subtracted from the images in the second study to obtain those during the acetazolamide test after correction of the time differences in data acquisition between the two studies. This subtraction technique gives independent brain perfusion SPECT images before and during the acetazolamide test. Besides, the regional flow changes during the test were quantitatively analyzed. In conclusion this method seems to be practically useful for evaluating regional brain perfusion before and during drug treatments as a consecutive study with a short period of approximately 30 min. (author).

  13. HMPAO-SPECT during epileptic seizures: Early and late images

    International Nuclear Information System (INIS)

    Overbeck, B.; Gruenwald, F.; Bockisch, A.; Biersack, H.J.; Reinke, U.; Gratz, K.F.

    1990-01-01

    For presurgical evaluation of epilepsy a 44-year old patient with complex-partial seizures underwent HMPAO-SPECT. The morphology of the seizures, the MRI-scan, psychometry and ictal as well as interictal EEGs showed a left temporal origin of the seizures. Early images were obtained 20 min and late images 24 h following injection. On both scans a marked hyperperfusion was observed in the left temporal area. A crossed cerebellar diaschisis was also seen on both SPECTs. It could be shown that during ictal examinations there is no bloodflow-dependent wash-out from brain tissue. (orig.) [de

  14. Usefulness of {sup 99m}Tc-HMPAO SPECT in Patients with Subarachnoid Hemorrhage due to Ruptured Intracranial Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, C. W.; Lee, K. H.; Kim, J. H.; Kwark, C. E.; Lee, D. S.; Chung, J. K.; Lee, M. C.; Han, D. H.; Koh, C. S. [Seoul National University Hospital, Seoul (Korea, Republic of)

    1993-07-15

    We evaluated the usefulness of {sup 99m}Tc-HMPAO SPECT in 21 Patients with subarachnoid hemorrhage due to ruptured intracranial aneurysm and in 3 patients with unruptured intracranial aneurysm. SPECT study could detect the bilaterally hypoperfused cases in 10 patients(48%), but CT/MRI showed the bilateral abnormalities in only 3 patients(14%). The number of abnormal lesions were 56 in SPECT and 25 in CT/MRI. The lesions found in SPECT were well correlated with the neurological signs of the patients such as aphasia or hemiplegia. SPECT study during Matas test was helpful in evaluating the risk for carotid artery occlusion therapy. We thought that {sup 99m}Tc-HMPAO brain SPECT is helpful in evaluating the functional changes in patients with subarachnoid hemorrhage.

  15. 99mTc-HMPAO SPECT in patients with Alzheimer's disease and multiinfraction dementia

    International Nuclear Information System (INIS)

    Klisarova, A.; Tranulov, G.; Deleva, N.; Kaprelian, A.; Terzieva, M.; Ivanov, B.

    2002-01-01

    Alzheimer's disease (AD) and multiinfarktion dementia (MD) are the commonest causes giving rise to progressive cognitive function deficit in adult individuals. It is the purpose of the study to evaluate 99m Tc-HMPAO SPECT in making the diagnosis and differential diagnosis of Alzheimer's disease and multiinfarction dementia in patients presenting progressive cognitive disorders. Twenty patients with symptoms of dementia divided up in two groups (10 suspected for AD, and 10 with evidence of MD) are subjected to 99m Tc-HMPAO SPECT. To assay the scintigraphic images semi-quantitative perfusion indices are introduced. Bilateral hypoperfusion zones in the temporoparietal and temporal regions are detected in nine AD patients. In 4 of them in advanced stage of the disease hypoperfusion zones are found in the frontal lobe. In 8/10 MD patients vascular dependent hypoperfusion areas are located along the course of vessels. The perfusion indices implemented in practice contribute to the semi-quantitative evaluation of hypoperfusion areas and precise assessment of the scintigraphic findings. 99m Tc-HMPAO SPECT is an atraumatic, noninvasive technique, taken to be the method of choice in making the diagnosis and differential diagnosis of Alzheimer's disease and multiinfarction dementia in routine clinical practice. (authors)

  16. Diagnosis of ischemic cerebrovascular diseases with 99mTc-HMPAO brain SPECT using upright stress test

    International Nuclear Information System (INIS)

    Chen Shaoliang; Xiu Yan; Sun Xiaoguang

    1998-01-01

    Purpose: To evaluate the value of upright brain SPECT stress test, the authors performed 99m Tc-HMPAO brain SPECT in association with measurement of blood pressure in both upright and supine positions. Methods: The authors studied 5 patients with unilateral stenosis occlusion of the internal carotid (Group A), 8 patients with orthostatic hypotension (group B) and 7 normal controls. 370 MBq 99m Tc-HMPAO was injected immediately after uprighting from a supine position. then the first SPECT scan were performed. After the first SPECT, another 555 MBq of 99m Tc-HMPAO were administered while the patients remained on original supine position. Results: Semiquantitive analysis showed that the asymmetric ratios between upright and supine positions in group A changed significantly. In group B, showed postural cerebral hypoperfusion in the bilateral frontal areas, the mean count ratio of the frontal to cerebellar area between the upright and supine positions also significantly changed. In the normal group, there were no significantly changes during the upright test. Conclusions: The upright stress test is useful for detecting not only silent cerebral hypoperfusion, but also orthostatic hypoperfusion

  17. Technetium-99mTc-HMPAO brain SPECT in antiphospholipid syndrome - preliminary data

    International Nuclear Information System (INIS)

    Romanowicz, G.; Lass, P.; Koseda-Dragan, M.; Nowicki, R.; Krajka-Lauer, J.

    2000-01-01

    Background: Antiphospholipid syndrome (APS) is defined as the presence of repeated episodes of arterial or venous thrombosis, recurrent spontaneous abortions and throbocytopenia in patients with elevated antiphospholipid antibodies. An important feature of APS are cerebrovascular disorders of thrombotic origin. The aim of the study was to assess cerebral blood flow changes utilising brain SPECT HMPAO scanning. METHODS: Brain SPECT 99mTc-HMPAO scanning was performed in 20 patients with APS: 12 with systemic lupus erythematosus, 4 with Sneddon's syndrome, 2 with Sjoegren's syndrome, 2 with primary APS. 30 healthy volunteers served as a control group. RESULTS: 19 studies were abnormal, 1 normal. Abnormalities consisted of multifocal perfusion deficits and diffuse decrease of regional blood flow. The average number of focal perfusion deficits was 4.8±1.7. In 7 patients diffuse hypoperfusion of frontal lobes was seen, in 1 patient additionally hypoperfusion of temporal and occipital lobes. There was a correlation between the number of focal perfusion deficits and cognitive impairment in this group of patients. Correlation between SPECT images and clinical data was moderate in cerebellar syndrome and paresis, weak in persistent headache and vertigo. CONCLUSIONS: Those results indicate the high utility of CBF brain SPECT scanning in antiphospholipid syndrome. (author)

  18. MRI and HMPAO-SPECT in the diagnosis of epilepsy

    International Nuclear Information System (INIS)

    Bokisch, A.; Gruenwald, F.; Elger, C.E.; Kaiser, W.A.; Biersack, H.J.

    1992-01-01

    Eighty-three patients suffering from intractable epilepsy were investigated by magnetic resonance imaging (MRI) and by HMPAO-SPECT during presurgical evaluation. MRI was proven to be most sensitive concerning the detection of focal lesions. Acquisition of thin slices and high signal/noise ratios are prerequisites for optimal sensitivity, the use of Gd-DTPA, in addition, increases the reliability slightly. Histological findings were available in 21 patients and in all cases of focal lesions without prior surgery, malignancy was detected or excluded correctly. The sensitivity was reduced, however, in the 4 patients with recurrency of astrocytoma. 2 cases were missed. Quantitative evaluation of signal intensities in the amygdala/hippocampal region or of the signal dynamics after contrast media application were not helpful in patients without focal lesion. In these patients no reliable criterium to determine the side of the focus with MRI investigations could be established. HMPAO-SPECT investigations were found to be complementary to MRI. In 19 of 36 patients without focal lesions the lateralisation was feasible by scintigraphy. In addition a correlation between the volume asymmetry of the temporal horns detected by MRI and the scintigraphic finding was established. The statistical proven correlation between the unilateral dilatation of the temporal horn and relative hypoperfusion is too weak, however, to imply individual consequences. (orig.) [de

  19. Hemodynamic and metabolic state of hyperfixation with 99mTc-HMPAO brain SPECT in subacute stroke

    International Nuclear Information System (INIS)

    Cho, Ihnho; Hayashida, Kohei; Imakita, Satoshi; Kume, Norihiko; Fukuchi, Kazuki

    2000-01-01

    By means of positron emission tomography (PET), we investigated the hemodynamic and metabolic state of the hyperfixation identified as the increased accumulation with 99m Tc-d, l-hexamethylpropyleneamine oxime (HMPAO) by single photon emission computed tomography (SPECT) in patients with subacute stroke. We studied four patients with subacute stroke having hyperfixed areas evaluated with CBF, CMRO 2 , OEF and CBV by PET. The hyperfixation rate with 99m Tc-HMPAO was obtained by comparing the surplus rate with standardized CBF. The OEF and CMRO 2 values in the hyperfixed areas of 4 patients were significantly lower than those in normal 5 controls (p 99m Tc-HMPAO in the infarct area revealing a mismatch between CMRO 2 and CBF meant relative luxury perfusion. The hyperfixation rate determined by 99m Tc-HMPAO brain SPECT correlated with CBV in the PET study. We can conclude that one of the main factors which caused hyperfixation was vasodilatation as well as the blood brain barrier disruption and the neovascularization. (author)

  20. Study of cerebrovascular diseases and SPECT with 99mTc HMPAO

    International Nuclear Information System (INIS)

    Collazo de la Maza, A.; Borron Molinos, M.; Barroso, E.

    1997-01-01

    Thirty eight patients with Cerebrovascular disease, that had suffered a Thrombotic brain infraction, demonstrated by Computed electroencephalogram or Brain Mapping (BM) and Computerized Tomography (CT) were investigated with '99' '9' 'm' Tc HM-PAO brain SPECT. Their ages ranged from 37 to 73 years old, 18 males and 20 female. Some of them were followed up with these diagnostic methods. The acquisition and processing of the SPECT studies were donw with a SOPHY DS7 Gamma Camera. The results showed that the global diagnostic sensibility of the SPECT was 79%. The sensibility of SPECT in the Acute stage was 75 %, CT 57% and BM 92%. In Steady stage we found a high positivity of SPECT with 83 %, Ct 66% and BM 66%. In the Recuperation Stage SPECT was 77%, CT 66% and 45%. Some phenomenon like the Luxury Perfusion and Diaschisis were studied and it is possible to found some prognostic relation

  1. Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Directory of Open Access Journals (Sweden)

    Chiara Bruni

    Full Text Available Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC with 99mTc-hexamethylpropylene amine oxime (HMPAO has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. 99mTc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of99mTc-HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with 99mTc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection.

  2. Clinical Utility of '99mTc-HMPAO Brain SPECT Findings in Chronic Head Injury

    International Nuclear Information System (INIS)

    Chung, Jin ll; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Doo; Park, Chang Yoon; Kim, Young Soo

    1992-01-01

    Minima deterioration of cerebral perfusion or microanatomical changes were undetectable on conventional Brain CT or MRI. So evaluation of focal functional changes of the brain parenchyme is essential in chronic head injury patients, who did not show focal anatomical changes on these radiological studies. However, the patients who had longstanding neurologic sequelae following head injury, there had been no available imaging modalities for evaluating these patients precisely. Therefore we tried to detect the focal functional changes on the brain parenchyme using 99m Tc-HMPAO Brain SPECT on the patients of chronic head injuries. Twenty three patients who had suffered from headache, memory dysfunction, personality change and insomnia lasting more than six months following head injury were included in our cases, which showed no anatomical abnormalities on Brain CT or MRI. At first they underwent psychological test whether the symptoms were organic or not. Also we were able to evaluate the cerebral perfusion changes with 99m Tc-HMPAO Brain SPECT in 22 patients among the 23, which five patients were focal and 17 patients were nonfocally diffuse perfusion changes. Thus we can predict the perfusion changes such as local vascular deterioration or functional defects using 99m Tc-HMPAO Brain SPECT in the patients who had suffered from post-traumatic sequelae, which changes were undetectable on Brain CT or MRI.

  3. Is SPECT useful in imaging of abdominal inflammatory processes using 99mTc-HMPAO-WBCs?

    International Nuclear Information System (INIS)

    Smole, M.S.; Stantic, T.S.; Fettich, J.F.

    2002-01-01

    Aim: The aim of the study is to determine whether SPECT gives additional information in the assessment of inflammation of the abdominal region with labelled white blood cells as compared with usual planar imaging. Patients And Methods: SPECT and planar imaging was performed in 26 patients with suspected inflammatory process in the abdomen, within three hours after injection of autologous white blood cells labelled with 99m Tc HMPAO. Planar images where acquired as static spot images using high resolution low energy collimator on 256 x 256 matrix. SPECT was performed using the same collimator on 128 x 128 matrix in 128 projections. Filtered back projection was used for reconstruction and volume rendering was performed. Results: The lesions in the abdomen were classified as jejunum, colon ascendents, colon transversum, colon descendents, sigmoid, and lesions outside GIT. All lesions, which were seen on planar images, except one, were also seen on SPECT. Five equivocal lesions seen on planar images were reconfirmed as pathological on SPECT. Additionally SPECT revealed three lesions not seen on planar images. Fourteen lesions were seen by both imaging techniques. All together SPECT improved diagnostic accuracy of 99m Tc - HMPAO - WBC scintigraphy in 7/28 patients. Conclusion: more inflammatory lesions in the abdomen are revealed by SPECT and volume rendering, than by planar imaging equivocal lesions seen on planar images can be characterised as positive or negative by SPECT. SPECT artefacts can cause possible false positive results; therefore usual planar imaging cannot be omitted if SPECT is performed

  4. Technetium-99m-HMPAO SPECT in the evaluation of patients with a remote history of traumatic brain injury: a comparison with x-ray computed tomography.

    Science.gov (United States)

    Gray, B G; Ichise, M; Chung, D G; Kirsh, J C; Franks, W

    1992-01-01

    The functional imaging modality has potential for demonstrating parenchymal abnormalities not detectable by traditional morphological imaging. Fifty-three patients with a remote history of traumatic brain injury (TBI) were studied with SPECT using 99mTc-hexamethylpropyleneamineoxime (HMPAO) and x-ray computed tomography (CT). Overall, 42 patients (80%) showed regional cerebral blood flow (rCBF) deficits by HMPAO SPECT, whereas 29 patients (55%) showed morphological abnormalities by CT. Out of 20 patients with minor head injury, 12 patients (60%) showed rCBF deficits and 5 patients (25%) showed CT abnormalities. Of 33 patients with major head injury, 30 patients (90%) showed rCBF deficits and 24 patients (72%) showed CT abnormalities. Thus, HMPAO SPECT was more sensitive than CT in detecting abnormalities in patients with a history of TBI, particularly in the minor head injury group. In the major head injury group, three patients showed localized cortical atrophy by CT and normal rCBF by HMPAO SPECT. In the evaluation of TBI patients, HMPAO SPECT is a useful technique to demonstrate regional brain dysfunction in the presence of morphological integrity as assessed by CT.

  5. Correlation of Tc-99m HMPAO SPECT with surface EEG, MR, and CT for noninvasive localization of seizure foci

    International Nuclear Information System (INIS)

    Engelstad, B.L.; Laxer, K.D.; Dickson, H.S.; Cooper, K.E.; Huberty, J.P.; White, D.L.

    1987-01-01

    Some patients with refractory seizure disorders are candidates for surgical management. Correct preoperative lateralization is essential. Of 19 patients with seizure disorders who underwent Tc-99m HMPAO SPECT, 14 were considered to have ultimately had definitive localization by other means: consistently abnormal surface electroencephalogram (EEG), subdural or deep electrode EEG, EEG response to resection, abnormal histopatholgy, or grossly abnormal MR image. Lateralization with SPECT was (1) focal or regional hypoperfusion (11 patients) or (2) discrete focal hyperperfusion (one patient). Correct lateralization was obtained in ten of 14 with SPECT, nine of 14 with surface EEG, seven of 12 with MR, and one of eight with CT. Preoperative evaluation of patients with medically refractory seizures can be aided by Tc-99m HMPAO SPECT

  6. Herpes simplex encephalitis: increased retention of Tc-99m HMPAO on acetazolamide enhanced brain perfusion SPECT

    International Nuclear Information System (INIS)

    Choi, Yun Young; Kim, Kwon Hyung; Kim, Seung Hyun; Cho, Suk Shin

    1998-01-01

    We present an interesting case of herpes simplex encephalitis, which showed increased upta unilateral temporal cortex on brain perfusion SPECT using Tc-99m HMPAO, but in bilateral tem cortex after acetazolamide administration. A 42-year-old man was admitted via emergency room, due to rapidly progressing hea disorientation and mental changes. On neurologic examination, neck stiffness and Kernig sign noted. CSF examination showed pleocytosis with lymphcyte predominance. MRI showed swelling bilateral temporal lobe with left predominance, suggestive of herpes simplex encephalitis. Baseline/ Acetazolamide brain perfusion SPECT were acquired consecutively at the same position IV administration of 740MBq and additional 1480 MBq of Tc-99m HMPAO respectively. The temporal and inferior frontal cortex showed markedly increased perfusion on the baseline acetazolamide-enhanced SPECT images. The right temporal cortex showed normal uptake on the b SPECT images, and markedly increased uptake after acetazolamide administration, which seemed to the abundant vascularity at the acute inflammation site without marked brain damage. The fo brain perfusion SPECT after 6 months showed perfusion defect in left temporal cortex but norm perfusion in right temporal cortex. Therefore, we can conclude that baseline SPECT is helpful for the prediction of the prognosis acetazolamide SPECT for the evaluation of the extent of herpes simples encephalitis

  7. Analysis of Regional Cerebral Blood Flow Using 99mTc-HMPAO Brain SPECT in Senile Dementia of Alzheimer Type

    International Nuclear Information System (INIS)

    Lee, Myung Hae; Lee, Myung Chul; Koh, Chang Soon; Roh, Jae Kyu; Woo, Chong In

    1988-01-01

    99m Tc-HMPAO brain SPECT studies were performed in 11 patients with Alzheimer's disease, 7 patients with psychological depression and 12 normal controls. Changes of regional cerebral blood flow was semiquantitatively analyzed and the results were as follows. 1) In 11 patients with Alzheimer's disease, significant reduction of regional cerebral blood flow was found In both temporoparietal areas. 2) Relative perfusion between cerebral hemispheres was rather symmetrical in patient with Alzheimer's disease. 3) All patients with depression showed normal SPECT findings. As for conclusion, 99m Tc-HMPAO brain SPECT seemed to be a valuable method for clinical assessment and management of patients with Alzheimer's disease.

  8. Usefulness of hybrid SPECT/CT for the {sup 99m}Tc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Bruni, Chiara; Padovano, Federico; Travascio, Laura; Schillaci, Orazio; Simonetti, Giovanni [University of Rome Tor Vergata, Rome (Italy). Dept. of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy]. E-mail: chiarabruni79@hotmail.com

    2008-12-15

    Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC) with {sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. {sup 99m}Tc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of {sup 99m}Tc- HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with {sup 99m}Tc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection. (author)

  9. A Case of Habitual Neck Compression Induced Electroencephalogram Abnormalities: Differentiating from Epileptic Seizures Using a Tc-99m HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hongyoon; Seo, Minseok; Lee, Hoyoung; Kim, Youngsoo; Yun, Changho; Kim, Sangeun; Park, Sungho [Seoul National Univ. Bundang Hospital, Seongnam (Korea, Republic of)

    2014-06-15

    Self-induced hypoxia has been reported particularly in adolescents, and it can result in neurological injury. Here, we present a case of electroencephalogram (EEG) abnormalities induced by habitual neck compression differentiated from epileptic seizures by Tc-99m HMPAO SPECT. A 19-year-old male was admitted for evaluation of recurrent generalized tonic-clonic seizures. No interictal EEG abnormality was detected; however, abnormal slow delta waves were found immediately after habitual right neck compression. To differentiate EEG abnormalities due to a hemodynamic deficit induced by habitual neck compression from an epileptic seizure, Tc-99m HMPAO SPECT was performed immediately after right carotid artery compression. Abnormal delta waves were triggered, and cerebral hypoperfusion in the right internal carotid artery territory was detected on Tc-99m HMPAO SPECT. The slow delta wave detected on the EEG resulted from the cerebral hypoperfusion because of the habitual neck compression.

  10. A Case of Habitual Neck Compression Induced Electroencephalogram Abnormalities: Differentiating from Epileptic Seizures Using a Tc-99m HMPAO SPECT

    International Nuclear Information System (INIS)

    Choi, Hongyoon; Seo, Minseok; Lee, Hoyoung; Kim, Youngsoo; Yun, Changho; Kim, Sangeun; Park, Sungho

    2014-01-01

    Self-induced hypoxia has been reported particularly in adolescents, and it can result in neurological injury. Here, we present a case of electroencephalogram (EEG) abnormalities induced by habitual neck compression differentiated from epileptic seizures by Tc-99m HMPAO SPECT. A 19-year-old male was admitted for evaluation of recurrent generalized tonic-clonic seizures. No interictal EEG abnormality was detected; however, abnormal slow delta waves were found immediately after habitual right neck compression. To differentiate EEG abnormalities due to a hemodynamic deficit induced by habitual neck compression from an epileptic seizure, Tc-99m HMPAO SPECT was performed immediately after right carotid artery compression. Abnormal delta waves were triggered, and cerebral hypoperfusion in the right internal carotid artery territory was detected on Tc-99m HMPAO SPECT. The slow delta wave detected on the EEG resulted from the cerebral hypoperfusion because of the habitual neck compression

  11. Analysis of Regional Cerebral Blood Flow Using {sup 99m}Tc-HMPAO Brain SPECT in Senile Dementia of Alzheimer Type

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Hae; Lee, Myung Chul; Koh, Chang Soon; Roh, Jae Kyu; Woo, Chong In [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1988-03-15

    {sup 99m}Tc-HMPAO brain SPECT studies were performed in 11 patients with Alzheimer's disease, 7 patients with psychological depression and 12 normal controls. Changes of regional cerebral blood flow was semiquantitatively analyzed and the results were as follows. 1) In 11 patients with Alzheimer's disease, significant reduction of regional cerebral blood flow was found In both temporoparietal areas. 2) Relative perfusion between cerebral hemispheres was rather symmetrical in patient with Alzheimer's disease. 3) All patients with depression showed normal SPECT findings. As for conclusion, {sup 99m}Tc-HMPAO brain SPECT seemed to be a valuable method for clinical assessment and management of patients with Alzheimer's disease.

  12. Evaluation of the effects of methylprednisolone pulse therapy in patients with systemic lupus erythematosus with brain involvement by Tc-99m HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, S.S.; Kao, C.H. [Department of Nuclear Medicine, China Medical University Hospital, Taichung (Taiwan); Huang, W.S. [Department of Nuclear Medicine, National Defense Medical Center, Tri-Service General Hospital, Taipei (Taiwan); Chen, J.J.H. [Section of Rheumatology, Department of Internal Medicine, China Medicine University Hospital, Taichung (Taiwan); Chang, C.P. [Division of Allergy, Immunology and Rheumatology, Changhua Christian Hospital, Changhua (Taiwan); Wang, J.J. [Department of Medical Research, Chi-Mei Medical Center, Tainan (Taiwan)

    2004-07-01

    Methylprednisolone pulse therapy (MPT) was introduced to avoid life-threatening complications in patients with systemic lupus erythematosus (SLE) with brain manifestations; however, the efficacy of MPT in SLE patients with brain involvement is still uncertain and needs to be objectively evaluated. We enrolled 15 female SLE patients with neuropsychiatric manifestations in this study. All patients had normal brain MRI and abnormal brain HMPAO-SPECT findings. Follow-up HMPAO-SPECT studies were conducted 2 weeks after MPT. Serum levels of anticardiolipin antibodies (ACA) and anti-ribosomal P antibodies (anti-P) were measured before and after MPT. Before MPT, 7 patients were positive for ACA and 7 patients were positive for anti-P. After MPT, none of the 15 patients demonstrated positive serologic findings or neuropsychiatric manifestations. Based on the follow up brain HMPAO-SPECT images following MPT, 13 patients showed disappearance of the perfusion defects and 2 patients showed partial recovery of rCBF. Brain HMPAO-SPECT imaging is a logical and objective tool for measuring the effects of MPT in SLE patients with brain involvement by determining of changes in rCBF. (orig.)

  13. A study of acetazolamide-induced changes in cerebral blood flow using {sup 99m}Tc HMPAO SPECT in patients with cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Asenbaum, S. [Neurological Clinic, Univ. Vienna (Austria); Reinprecht, A. [Neurosurgical Clinic, Univ. Vienna (Austria); Bruecke, T. [Neurological Clinic, Univ. Vienna (Austria); Wenger, S. [Neurological Clinic, Univ. Vienna (Austria); Podreka, I. [Neurological Clinic, Univ. Vienna (Austria); Deecke, L. [Neurological Clinic, Univ. Vienna (Austria)

    1995-01-01

    For semiquantification of SPECT studies we tried to calculate cerebral {sup 99m}Tc-HMPAO uptake related to injected dose and estimated brain volume. The method was applied to SPECT investigations of 27 patients who had a least one ischaemic attack and a confirmed 80-100% stenosis of the corresponding internal carotid artery (ICA). Vascular reactivity was tested by parenteral administration of acetazolamide (AZ). Increase in HMPAO uptake after AZ was evident in both hemispheres, although the increase (AZ effect) was significantly lower in the affected hemisphere (+24% versus +28%). No interhemispheric uptake differences were seen in patients with largely normal SPECT studies, although local asymmetries in HMPAO deposition were visible. Patients with low density lesions on CT and with a well-demarcated lesion in the same location on SPECT revealed interhemispheric uptake differences, with lower uptake on the affected side. This was not due solely to alterations in the lesion, but also to reduced HMPAO uptake and AZ effect in the surrounding area. The AZ effect showed no correlation with angiographic findings, indicating no major haemodynamic influence of the ICA stenosis on cerebral hemisphere perfusion. Calculated cerebral HMPAO uptake changes after AZ administration were in good accordance with absolute cerebral blood flow measurements, and made interindividual comparisons possible. However, as changes in the area around an infarct or local reduction in vascular reserve may not be reproduced adequately by uptake calculations, visual inspection is still necessary. (orig.)

  14. Functional and morphological findings in early and advanced stages of HIV infection: A comparison of 99mTc-HMPAO SPECT with CT and MRI studies

    International Nuclear Information System (INIS)

    Tatsch, K.; Bauer, W.M.; Markl, A.; Kirsch, C.M.; Schielke, E.; Einhaeupl, K.M.

    1990-01-01

    In fourty patients at early and advanced stages of HIV infection (Water-Reed stages I-VI) regional cerebral blood flow was determined by 99m Tc-HMPAO SPECT, comparing the results with CT and MRI findings. All patients with HIV encephalopathy (AIDS dementia complex) had pathologic SPECT results (multilocular, patchy uptake defects), but also in earlier and even earliest stages of HIV infection positive SPECT findings were observed. Compared to functional SPECT imaging, morphologically orientated method (CT, MRI) were insensitive in detecting HIV-induced foci: More than 50% of the patients with pathologic SPECT findings had negative CT or MRI scans. Most patients in advanced Walter Reed stages had neurological abnormalities accompanied by positive SPECT. Subtle alterations of HMPAO uptake were observed even in a few cases of early HIV infection without neurological CNS symptoms. The data presented suggest that HMPAO SPECT is highly sensitive in the detection of altered brain perfusion not only in advanced but also early stages of HIV infection. Changes in regional cerebral blood flow are presented before noticeable structural defects may be observed. (orig./MG) [de

  15. A comparative study of perfusion CT and 99mTc-Hmpao spect measurement to assess cerebrovascular reserve capacity in patients with internal carotid artery occlusion

    Directory of Open Access Journals (Sweden)

    Eicker S

    2011-11-01

    Full Text Available Abstract Background and purpose Patients with internal carotid artery (ICA occlusion can demonstrate impaired cerebral vascular reserve (CVR. The detection of CVR using single photon emission CT (SPECT is nowadays widely accepted as a predictor in the diagnostic pathway in patients considered for cerebral revascularization. Recently perfusion CT (PCT gained widely acceptance in stroke imaging The present study was aimed at comparing the results of perfusion CT (PCT and 99mTc-HMPAO SPECT with acetazolamide challenge in patients with ICA occlusion. Methods 13 patients were included in the prospective evaluation. Both PCT and 99mTc-HMPAO SPECT were performed before and after the administration of acetazolamide. In detail, regional cerebral blood flow (rCBF, regional cerebral blood volume (rCBV, adapted time to peak (Tmax and mean transit times (MTT were compared with SPECT data. Results 99mTc-HMPAO SPECT demonstrated an impairment of CVR in six patients. A preserved CVR was present in seven patients. All patients with impaired CVR proven by SPECT had a delayed MTT (mean +2.98 s and a delayed Tmax (mean + 5.9 s, (both p Conclusion The prospective study demonstrated a highly significant correlation of perfusion parameters as' detected by 99mTc-HMPAO SPECT and the Tmax as detected by PCT in patients with ICA occlusion. Therefore this easy-to-perform technique seems to be an adequate method for the evaluation of cerebral perfusion in patients with ICA occlusion.

  16. Clinical Utility of '9{sup 9m}Tc-HMPAO Brain SPECT Findings in Chronic Head Injury

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jin ll; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Doo; Park, Chang Yoon; Kim, Young Soo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1992-03-15

    Minima deterioration of cerebral perfusion or microanatomical changes were undetectable on conventional Brain CT or MRI. So evaluation of focal functional changes of the brain parenchyme is essential in chronic head injury patients, who did not show focal anatomical changes on these radiological studies. However, the patients who had longstanding neurologic sequelae following head injury, there had been no available imaging modalities for evaluating these patients precisely. Therefore we tried to detect the focal functional changes on the brain parenchyme using {sup 99m}Tc-HMPAO Brain SPECT on the patients of chronic head injuries. Twenty three patients who had suffered from headache, memory dysfunction, personality change and insomnia lasting more than six months following head injury were included in our cases, which showed no anatomical abnormalities on Brain CT or MRI. At first they underwent psychological test whether the symptoms were organic or not. Also we were able to evaluate the cerebral perfusion changes with {sup 99m}Tc-HMPAO Brain SPECT in 22 patients among the 23, which five patients were focal and 17 patients were nonfocally diffuse perfusion changes. Thus we can predict the perfusion changes such as local vascular deterioration or functional defects using {sup 99m}Tc-HMPAO Brain SPECT in the patients who had suffered from post-traumatic sequelae, which changes were undetectable on Brain CT or MRI.

  17. Functional brain SPECT with 99mTc-HMPAO in the diagnosis of Alzheimer disease

    International Nuclear Information System (INIS)

    Urbanek, J.; Kupka, K.; Samal, M.; Jirak, R.; Obenberger, J.

    1998-01-01

    The explanatory power of perfusion diagrams obtained by the title technique was examined. In addition to the standard reconstruction procedure, a special reorientation procedure aimed at a differentiation of the hippocampus structure was applied. The study gave evidence of a high specificity and sensitivity of brain SPECT in the differential diagnosis of dementias. Multifactorial analysis of all available diagnostic techniques has borne out the dominant position of brain SPECT with 99m Tc-HMPAO, particularly when using special projection onto the hippocampus, and has led to the formulation of an examination algorithm where a combination of SPECT and MRI (and CT) enables DAT to be distinguished from dementias of other etiologies with a probability higher than 90%

  18. Technetium-99m-HMPAO SPECT, CT and MRI in the evaluation of patients with chronic traumatic brain injury: a correlation with neuropsychological performance.

    Science.gov (United States)

    Ichise, M; Chung, D G; Wang, P; Wortzman, G; Gray, B G; Franks, W

    1994-02-01

    The purposes of this study were: (1) to compare 99mTc-hexamethylpropyleneamineoxime (HMPAO) SPECT with CT and MRI in chronic traumatic brain injury (TBI) patients and (2) to correlate both functional and structural neuroimaging measurements of brain damage with neuropsychological (NP) performance. Twenty-nine patients (minor TBI, n = 15 and major TBI, n = 14) and 17 normal controls (NC) underwent HMPAO SPECT, CT, MRI and NP testing. Imaging data were analyzed both visually and quantitatively. Nineteen (66%) patients showed 42 abnormalities on SPECT images, whereas 13 (45%) and 10 (34%) patients showed 29 abnormalities on MRI and 24 abnormalities on CT. SPECT detected relatively more abnormalities than CT or MRI in the minor TBI subgroup. The TBI group showed impairment on 11 tests for memory, attention and executive function. Of these, the anterior-posterior ratio (APR) correlated with six tests, whereas the ventricle-to-brain ratio (VBR), a known structural index of a poor NP outcome, correlated with only two tests. In evaluating chronic TBI patients, HMPAO SPECT, as a complement to CT or MRI, may play a useful role by demonstrating brain dysfunction in morphologically intact brain regions and providing objective evidence for some of the impaired NP performance.

  19. Combined study of 99mTc-HMPAO SPECT and computerized electroencephalographic topography (CET) in patients with medically refractory complex partial epilepsy

    International Nuclear Information System (INIS)

    Rodrigues, M.; Botelho, M.M.; Fonseca, A.T.; Peter, J.P.; Pimentel, T.; Vieira, M.R.

    1996-01-01

    For successful surgery for drug-resistant partial epilepsy the site of the seizure focus needs to be known exactly. The purpose of this study was to compare the evaluation of the regional cerebral blood flow (rCBF) (localization and degree of disturbances) by 99m Tc-hexamethylpropylene-amineoxime (HMPAO) single photon emission computed tomography (SPECT) with computerized electroencephalographic topography (CET) and transmission computed X-ray tomography (CT) in partial epilepsy. The study included 20 patients with medically refractory complex partial seizures. Of the 20 patients included, 15 were studied interictally, four ictally and one in both states, interictally and ictally. 99m Tc-HMPAO SPECT detected rCBF changes in 95% of the patients. Interictal studies demonstrated focal areas of hypoperfusion in 93% of the patients. Ictal studies demonstrated an area of hyperperfusion in all patients. Blood flow disturbances in deeper structures of the brain, such as basal ganglia, could be detected. The areas with abnormal 99m Tc-HMPAO uptake were concordant, in localization, with CET in 85% of the patients. Abnormal data with CT scans were found in only 45% of the patients. Focal lesions were found in 20% of the patients by CT scans. 99m Tc-HMPAO SPECT combined with CET may be a useful screening procedure prior to referral for invasive diagnostic procedures in future management of patients with medically refractory complex partial seizures. (author)

  20. Technetium-99m-HMPAO labeled leukocyte single photon emission computerized tomography (SPECT) for assessing Crohn's disease extent and intestinal infiltration.

    Science.gov (United States)

    Biancone, L; Schillaci, O; Capoccetti, F; Bozzi, R M; Fina, D; Petruzziello, C; Geremia, A; Simonetti, G; Pallone, F

    2005-02-01

    Scintigraphy using radiolabeled leukocytes is a useful technique for assessing intestinal infiltration in Crohn's disease (CD). However, limits of planar images include overlapping activity in other organs and low specificity. To investigate the usefulness of (99m)Tc-HMPAO (hexametyl propylene amine oxime) labeled leukocyte single photon emission computerized tomography (SPECT) for assessing CD lesions, in comparison with planar images. Twenty-two inflammatory bowel disease patients (19 CD; 2 ulcerative colitis, UC; 1 ileal pouch) assessed by conventional endoscopy or radiology were enrolled. Leukocytes were labeled with (99m)Tc-HMPAO. SPECT images were acquired at 2 h and planar images at 30 min and 2 h. Bowel uptake was quantitated in nine regions (score 0-3). Both SPECT and planar images detected a negative scintigraphy (score 0) in the UC patient with no pouchitis and a positive scintigraphy (score 1-3) in the 21 patients showing active inflammation by conventional techniques. SPECT showed a higher global score than planar images (0.71 +/- 0.09 vs 0.30 +/- 0.05; p < 0.001), and in particular in the right iliac fossa (p= 0.003), right and left flank (p < 0.001; p= 0.02), hypogastrium (p= 0.002), and mesogastrium (p < 0.001). SPECT provided a better visualization and a higher uptake than planar images in patients with ileal and ileocolonic CD (6.45 +/- 0.82 vs 2.8 +/- 0.55, p < 0.001; 5.5 +/- 1.6 vs 2.6 +/- 0.7, p= 0.03), and with perianal CD (6.6 +/- 1.6 vs 3.4 +/- 1.2; p= 0.03). (99m)Tc-HMPAO labeled leukocyte SPECT provides a more detailed visualization of CD lesions than planar images. This technique may better discriminate between intestinal and bone marrow uptake, thus being useful for assessing CD lesions within the pelvis, including perianal disease.

  1. Pre-operative evaluation of medically intractable partial seizures using [sup 123]I-Iomazenil SPECT. Comparison with Video/EEG-monitoring and post-operative results. Praeoperative Bewertung pharmakoresistenter fokaler Epilepsien mit der [sup 123]J-Iomazenil-SPECT. Vergleich mit dem Video/EEG-Monitoring und postoperativen Ergebnissen

    Energy Technology Data Exchange (ETDEWEB)

    Venz, S [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Cordes, M [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Straub, H B [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Hierholzer, J [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Schroeder, R [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Richter, W [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Schmitz, B [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Ber

    1994-10-01

    SPECT with the benzodiazepine receptor antagonist [sup 123]I-Iomazenil was performed in 33 patients with intractable partial seizures for pre-operative evaluation. The results combined with MRI and [sup 99m]Tc-HMPAO-SPECT findings were compared with the video-assisted EEG monitoring (gold standard'') which localised the focus in 25 patients. 11 patients underwent surgical resection of the epileptogenic area and became seizure-free for a period up to 13 months. The lomazenil SPECT had a significantly higher sensitivity compared to [sup 99m]Tc-HMPAO in the visualization of an epileptogenic area and should be regularly used in the diagnostic of medically intractable partial seizures. (orig.)

  2. Increased cerebral blood flow in MELAS shown by Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Peng, N.J.; Tsay, D.G.; Liu, R.S.; Li, J.Y.; Kong, K.W.; Kwok, C.G.; Strauss, H.W.

    2000-01-01

    We report cerebral SPECT studies on two siblings with the syndrome of mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS). Tc-99m HMPAO brain SPECT was performed 8, 19 and 30 days after a stroke-like episode in one case and 10 days after a stroke-like episode, 6 h after a partial seizure and as a follow-up study in the other. Increased blood flow was seen in both these patients with stroke-like episodes due to MELAS. The cause of the increased blood flow is uncertain, but it may be related to the decreased pH created by local increase in lactic acid. (orig.)

  3. Analysis of simulataneous I-123-IPT/Tc-99m-HMPAO dual isotope brain SPECT in Parkinson's disease and normal volunteers using SPM

    International Nuclear Information System (INIS)

    Chung, Y. A.; Juh, R. H.; Kim, S. H.; Park, Y. H.; Lee, S. Y.; Sohn, H. S.; Chung, S. K.

    2002-01-01

    The basal ganglia are usually poorly delineated in Parkinson's diseases on IPT images. We have studied simultaneous dual isotope brain SPECTs using I-123-IPT and Tc-99m-HMPAO, in order to overcome this limitation of IPT imaging. 17 patients (M: 7, F: 10) with Parkinson's disease (Idiopathic parkison's disease: 12, Multiple system atrophy: 5) and 4 normal volunteers (N) underwent the dual isotope brain SPECT following simultaneously injection of 370 MBq Tc-99m-HMPAO (energy window: 130-146 keV) and 111 MBq I-123-IPT (energy window: 152-168 keV). We first obtained parameters of spatial normalization during spatial normalization of Tc-99m-HMPAO brain SPECT using SPECT template. Using these parameters, we could spatially normalized I-123-IPT brain PSECT to standard space, because these images were obtained simultaneously. The difference between each groups(N vs IPD, N vs MSA, IPD vs MSA) were compared with t-test (p<0.01). We demonstrated decreased perfusion in the head and body caudate and globus pallidus on MSA compared with IPD. No significant hypo- and hyperperfusion area was observed in the other analysis. The method proposed in this study can effectively evaluate the dopamine function, and is easily applicable to conventional gamma camera system with any dual energy window acquisition modes

  4. Brain SPECT by intraarterial infusion of 99mTc-HMPAO for assessing the cerebral distribution of carotid artery infusions in patient with brain tumor

    International Nuclear Information System (INIS)

    Kosuda, Shigeru; Kusano, Shoichi; Aoki, Shigeki

    1993-01-01

    In order to assess the cerebral distribution of intracarotid chemotherapy, 17 postoperative patients with brain tumor underwent brain SPECT obtrained by intraarterial infusion of 18.5 MBq of 99m Tc-d,l,-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO). Injection methods were continuous (5.0 ml/min) or pulsatile infusion with supra- or infraophthalmic catheterization. The findings obtained by brain SPECT were frequently different from those of angiography and/or DSA. In supraophthalmic catheterization with continuous infusion, only 2 of 10 studies (20%) had homogeneous distribution and 5 of them (50%) had maldistribution of 99m Tc-HMPAO which appears in association with laminar flow effect. The remaining 3 studies showed localized distribution (two: tumor localization, one: healthy brain localization). On the other hand, all of 5 studies with pulsatile infusion had homogeneous distribution of 99m Tc-HMPAO. In infraophthalmic catheterization, all but one of 5 studies had homogeneous distribution with continuous infusion. These results suggest that pulsatile infusion may be effective in eliminating maldistribution of 99m Tc-HMPAO in supraophthalmic catheterization. In conclusion, we are convinced that 99m Tc-HMPAO is a useful intraarterial agent for assessing cerebral distribution of intracarotid chemotherpay. (author)

  5. Comparison of {sup 99m}Tc-HMPAO SPECT and MRI after Acute and Subacute Closed-Head Injury

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Won Jong; Lee, Sang Hoon; Sohn, Hyung Sun; Lee, Han Jin; Park, Jeong Mi; Chung, Soo Kyo; Kim, Choon Yul; Bahk, Yong Whee; Shin, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    The purpose of this study was to compare {sup 99m}Tc-HMPAO SPECT with MRI after acute and subacute closed head injury. There were thirty two focal lesions in all cases of these, Fifteen lesions(47%) were seen on both MRI and SPECT. Fourteen lesions(44%) were seen only on MRI. Three lesions(9%) were seen only on SPECT. Of the 14 lesions seen only on MRl, one was epidural hematoma, two were subdural hematoma, three were subdural hygroma, one was intracerebral hematoma, four were contusion, and three were diffuse axonal injuries. SPECT detected 52% of the focal lesions found on MRI. For the detection of lesions, MRl was superior to SPECT in fourteen cases, while SPECT was superior to MRI in three cases. In conclusion, there was a tendency that detection rate of the traumatic lesions was higher on MRI, but the SPECT could delineate more wide extent of lesion.

  6. Effect of linearization correction on statistical parametric mapping (SPM). A 99mTc-HMPAO brain perfusion SPECT study in mild Alzheimer's disease

    International Nuclear Information System (INIS)

    Ansar, A.B.; Osaki, Yasuhiro; Kazui, Hiroaki

    2006-01-01

    Statistical parametric mapping (SPM) was employed to investigate the regional decline in cerebral blood flow (rCBF) as measured by 99m Tc-hexamethyl propylene amine oxime (HMPAO) single photon emission computed tomography (SPECT) in mild Alzheimer's disease (AD). However, the role of the post reconstruction image processing on the interpretation of SPM, which detects rCBF pattern, has not been precisely studied. We performed 99m Tc-HMPAO SPECT in mild AD patients and analyzed the effect of linearization correction for washout of the tracer on the detectability of abnormal perfusion. Eleven mild AD (National Institute of Neurological and Communicative Disorders and National Institute of Radiological Sciences (NINCDS-ADRDA), male/female, 5/6; mean±SD age, 70.6±6.2 years; mean±SD mini-mental state examination score, 23.9±3.41; clinical dementia rating score, 1) and eleven normal control subjects (male/female, 4/7; mean±SD age, 66.8±8.4 years) were enrolled in this study. 99m Tc-HMPAO SPECT was performed with a four-head rotating gamma camera. We employed linearization uncorrected (LU) and linearization corrected (LC) images for the patients and controls. The pattern of hypoperfusion in mild AD on LU and LC images was detected by SPM99 applying the same image standardization and analytical parameters. A statistical inter image-group analysis (LU vs. LC) was also performed. Clear differences were observed between the interpretation of SPM with LU and LC images. Significant hypoperfusion in mild AD was found on the LU images in the left posterior cingulate gyrus, right precuneus, left hippocampus, left uncus, and left superior temporal gyrus (cluster level, corrected p 99m Tc-HMPAO SPECT with or without linearization correction, which should be carefully evaluated when interpreting the pattern of rCBF changes in mild Alzheimer's disease. (author)

  7. 99mTc-HMPAO-SPECT in the diagnosis of senile dementia of Alzheimer's type - a study under clinical routine conditions

    International Nuclear Information System (INIS)

    Stoppe, G.; Staedt, J.; Schuetze, R.; Kunert, H.J.; Ruether, E.; Koegler, A.; Sandrock, D.; Emrich, D.

    1995-01-01

    This study was designed to evaluate whether investigations of cerebral blood flow can be a helpful diagnostic tool in the differential diagnosis between (senile) dementia of Alzheimer's type [(S)DAT] and geriatric depression with cognitive impairment. Under clinical routine conditions we performed Single Photon Emission Computed Tomography (SPECT) using 99m Tc-Hexamethylpropyleneamine Oxime (HMPAO) in 23 patients with (S)DAT (14 f, 9 m; mean age 68.9 y), 17 patients with geriatric depression (9 f, 8 m; mean age 66.4 y) and 12 age-matched controls (9 f, 3 m; mean age 69.2 y). Semiquantitative analysis (corticocerebellar ratios) of eight different regions of interest (ROI) revealed a significantly ( p 99m Tc-HMPAO SPECT is a valuable additional tool in the differential diagnosis of depression and dementia in the elderly. (author)

  8. Functional imaging studies of cognition using 99mTc-HMPAO SPECT: empirical validation using the n-back working memory paradigm

    International Nuclear Information System (INIS)

    Ludwig, Catherine; Ribaupierre, Anik de; Chicherio, Christian; Terraneo, Luc; Magistretti, Pierre; Slosman, Daniel

    2008-01-01

    Functional activation protocols are widely applied for the study of brain-cognition relations. Only few take advantage of the intrinsic characteristics of SPECT, particularly those allowing cognitive assessment outside of the camera, in settings close to the standard clinical or laboratory ones. The purpose of the study was to assess the feasibility of a split-dose activation protocol with 99m Tc-HMPAO using low irradiation dose. A two-scans protocol was applied to 12 healthy young volunteers using 270 MBq of 99m Tc-HMPAO per scan, with each image associated to a particular experimental condition of the verbal n-back working memory task (0-back, 2-back). Subtraction method was used to identify regional brain activity related to the task. Voxel-wise statistical analysis showed left lateralized activity associated with the 2-back task, compared to the 0-back task. Activated regions, mainly prefrontal and parietal, were similar to those observed in previous fMRI and 15 O-PET studies. The results support the use of 99m Tc-HMPAO SPECT for the investigation of brain-cognition relations and demonstrate the feasibility of optimal quality images despite low radiopharmaceutical doses. The findings also acknowledge the use of HMPAO as a radioligand to capture neuro-energetic modulations linked to cognitive activity. They encourage extending the application of the described activation protocol to clinical populations. (orig.)

  9. Serial 99mTc-HMPAO Brain SPECT for Assessing Perfusion Improvement after DEAS in Moyamoya Patients

    International Nuclear Information System (INIS)

    Lee, Kyung Han; Lee, Sang Hyung; Yeo, Jeong Seok; Kwark, Chul Eun; Chung, June Key; Lee, Myoung Chul; Cho, Byoung Kyu; Koh, Chang Soon

    1994-01-01

    Encephalo-duro-arterio-synangiosis (EDAS) is a relatively new surgical procedure for treatment of childhood moyamoya disease. We assessed regional cerebral perfusion in moyamoya patients before (1.3 mo) and after (6.8 mo) EDAS with 99m Tc-HMPAO brain SPECT. A total of 21 EDAS operations in 17 moyamoya patients was included. Preoperative CT or MRI showed cerebral infarction in 14 patients and carotid angiography showed Suzuki grade 1 to V stenosis in 6%, 9%, 62%, 12% and 12% of the hemispheres respectively. Preoperative SPECT showed regional hypoperfusion in all patients, bilateral frontal and temporal loves being the most frequently involved site. 4 X 4 pixel sized ROIs were applied on the frontotemmporal cortex in 3 slice averaged transverse tomographic images. An index of regional perfusion was measured as; PI (%)=average FT activity/average cerebellar activity X 100 Pre-EDAS ipsilateral PI ranged from 23.7 to 98.4% (mean:74.3 ± 17%) and increased significantly after operation (81.4 ± 17%, p 90, 0.5) (p<0.001). The amount of perfusion improvement (PI) showed significant correlation with CI (r-0.42, p=0.04). PI did not, however, correlate with the amount of neovascularization assessed angiographically in 8 patients. Serial HMPAO SPECT is an useful noninvasive study for assessing perfusion improvement after EDAS in childhood moyamoya patients.

  10. Optimization method for the administered activity to patients in Tc-99-HMPAO cerebral blood flow SPECT in adults

    International Nuclear Information System (INIS)

    Perez Diaz, Marlen; Estevez Aparicio, Eric; Roque Diaz, Reinaldo; Hernandez Rodriguez, Carlos

    2002-01-01

    A method based on the construction of an image quality discriminant function is proposed. The parameters which characterise it are selected among the typical ones measured in a Tc 99m - HMPAO cerebral blood flow SPECT. The results are compared among groups of patient's studies who received different activity (430, 640 and 807 MBq), looking for the minimum that guaranty good image quality. A reduction in the administered 99m Tc-HMPAO activity to the patient down to 430 MBq was possible without affecting the tomographic image quality. The labelling yield was the main parameter that determined the image quality. (author)

  11. Functional imaging studies of cognition using {sup 99m}Tc-HMPAO SPECT: empirical validation using the n-back working memory paradigm

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Catherine; Ribaupierre, Anik de [University of Geneva, Center for Interdisciplinary Gerontology, Geneva (Switzerland); Chicherio, Christian [Max Planck Institute for Human Development, Center for Lifespan Psychology, Berlin (Germany); Terraneo, Luc [Geneva University Hospitals, Service of Nuclear Medicine, Geneva (Switzerland); Magistretti, Pierre [EPFL, Brain Mind Institute, Lausanne (Switzerland); Slosman, Daniel [Clinique Generale-Beaulieu, Nuclear Medicine Institute, Geneva (Switzerland)

    2008-04-15

    Functional activation protocols are widely applied for the study of brain-cognition relations. Only few take advantage of the intrinsic characteristics of SPECT, particularly those allowing cognitive assessment outside of the camera, in settings close to the standard clinical or laboratory ones. The purpose of the study was to assess the feasibility of a split-dose activation protocol with {sup 99m}Tc-HMPAO using low irradiation dose. A two-scans protocol was applied to 12 healthy young volunteers using 270 MBq of {sup 99m}Tc-HMPAO per scan, with each image associated to a particular experimental condition of the verbal n-back working memory task (0-back, 2-back). Subtraction method was used to identify regional brain activity related to the task. Voxel-wise statistical analysis showed left lateralized activity associated with the 2-back task, compared to the 0-back task. Activated regions, mainly prefrontal and parietal, were similar to those observed in previous fMRI and {sup 15}O-PET studies. The results support the use of {sup 99m}Tc-HMPAO SPECT for the investigation of brain-cognition relations and demonstrate the feasibility of optimal quality images despite low radiopharmaceutical doses. The findings also acknowledge the use of HMPAO as a radioligand to capture neuro-energetic modulations linked to cognitive activity. They encourage extending the application of the described activation protocol to clinical populations. (orig.)

  12. Evaluation of Gilles de la Tourette syndrome with [99mTc] HMPAO Brain SPECT

    International Nuclear Information System (INIS)

    Carreira, LCTF; Santos, A. O; Juarez, B. A; Leite, H. A; Lima, M. C. L; Ramos, C. D; Camargo, E. E

    2002-01-01

    Gilles de la Tourette syndrome (GLTS) is a disorder characterized by tics and several behavioral disturbances. Although GLTS is a relatively common disorder, little is known about its pathophysiology. Previous studies with SPECT and PET were performed in a small number of patients and have shown some discordant data. The aim of this study is to evaluate brain perfusion abnormalities in patients with GLTS and to correlate them with the clinical manifestations of the syndrome. Twenty-eight patients were submitted to brain [99mTc]-HMPAO SPECT. 82 percent of the patients had abnormal studies. The most frequent finding was perfusion abnormalities in the thalami in 16 patients (57 percent) and 85 percent of patients with hyperperfusion of one or both thalami had complex motor tics. This investigation has demonstrated that brain perfusion SPECT is able to identify cortical perfusion abnormalities, associated with clinical symptoms in patients with GLTS. These abnormalities involve the pre-frontal-striatal-thalamic-cortical pathways (Au)

  13. Technetium-labeled HM-PAO studies in patients with cerebrovascular disease

    International Nuclear Information System (INIS)

    Smith, F.W.; Sharp, P.F.; Gemmell, H.; Evans, N.T.; MacDonald, A.F.

    1986-01-01

    Technetium-labeled hexamethyl-propyleneamineoxime (HM-PAO) is a promising radiopharmaceutical for the demonstration of cerebral blood flow. Twenty-four patients who had experienced either acute stroke (AS) or transient ischemic attack (TIA) were studied by x-ray CT and SPECT using technetium-labeled HM-PAO total of 26 studies. HM-PAO has a cerebral distribution similar to that of iodoamphetamine, but labeling with technetium allows good SPECT imaging on demand in any nuclear medicine department. In ten of the 16 patients who had experienced AS, findings on HM-PAO and CT studies correlated well. In six patients reduced cortical perfusion was detected on HM-PAO imaging, but only small infarcts in the internal capsule were seen on CT. In four of the eight patients who had experienced TIA, neither study revealed any abnormality. In the remaining four, areas of cortical underperfusion were seen on HM-PAO imaging, whereas the CT examination was normal. The findings in this study suggest that HM-PAO imaging is a more sensitive method for demonstrating the extent of cerebral underperfusion in cases of cerebrovascular accident

  14. CBF patterns in different types of headache using 99mTc HMPAO and high resolution SPECT

    International Nuclear Information System (INIS)

    Jones, B.E.; Davies, P.G.; Costa, D.C.; Steiner, T.J.; Rose, F.C.; Jewkes, R.F.; Charing Cross Hospital, London

    1988-01-01

    High resolution SPECT studies have been performed using 99m Tc HMPAO on patients suffering from migraine, cluster headache or chronic tension headache. Reduced uptake of tracer in the right parieto-occipital cortex was seen in 6/8 patients suffering from classical or hemiplegic migraine and 2/10 patients suffering from common migraine. A high uptake of tracer was seen in the temporal muscle of some patients with chronic tension headache. Extracerebral uptake of radioactivity was also seen in the tissue surrounding the brain in a case injected with the HMPAO 45 minutes after it had been prepared and in metastatic skull lesions in patients suffering from cancer of the breast. It is therefore important to use high resolution instrumentation to avoid artifacts when using this technique. (orig.)

  15. Delayed reflow of an ischemic infarct after spontaneous thrombolysis studied by CBF tomography using SPECT and Tc-99m HMPAO

    DEFF Research Database (Denmark)

    Companioni, J M; Lassen, N A; Tfelt-Hansen, P

    1991-01-01

    A patient with a large ischemic infarct in the left middle cerebral artery territory was studied six times in the acute/subacute phase by cerebral blood flow (CBF) tomography using Tc-99m-HMPAO. The SPECT instrument used was a brain dedicated highly sensitive four-camera system (TOMOMATIC 232...

  16. A postural `stressed` cerebral HMPAO case study

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R.C.; Jost, G.M.; Bolitho, L.; Grantham, M. [Wangaratta District Hospital, VIC (Australia)

    1998-03-01

    Full text: This case study represents an example of the utility of postural hypoperfusion stressed HMPAO SPECT. An elderly woman of 78 with a long history of giddiness was referred to our laboratory for examination of possible cerebral ischaemia. She had recurrent dizzy episodes, sometimes posture related, over the past few years and had suffered several falls. Cerebral DSA revealed minimal disease. CT scans were reported as normal. Carotid duplex Doppler studies revealed bilateral plaque disease in the carotid bulbs extending to the origins of the ICAs which were not significant stenoses. Postural symptoms were induced by standing the patient up rapidly and HMPAO was administered at the same time. A SPECT scan of the brain was performed. Quantitative analysis showed a left to right decrease of 10.8% in the temporo-occipital area, 5.6% in the temporo-parietal area and 2.5% in the cerebellar and parietal areas. Images revealed moderately reduced tracer concentration in the left half of the cerebellum and the left occipital region extending as far forward as the temporo-parietal region A repeat HMPAO SPECT scan without stress was normal. This would appear to indicate reversible ischaemia in the left posterior region, and is consistent with the reported symptoms. This case illustrates the usefulness of HMPAO in the diagnosis of reversible cerebral ischaemia.

  17. A postural 'stressed' cerebral HMPAO case study

    International Nuclear Information System (INIS)

    Williams, R.C.; Jost, G.M.; Bolitho, L.; Grantham, M.

    1998-01-01

    Full text: This case study represents an example of the utility of postural hypoperfusion stressed HMPAO SPECT. An elderly woman of 78 with a long history of giddiness was referred to our laboratory for examination of possible cerebral ischaemia. She had recurrent dizzy episodes, sometimes posture related, over the past few years and had suffered several falls. Cerebral DSA revealed minimal disease. CT scans were reported as normal. Carotid duplex Doppler studies revealed bilateral plaque disease in the carotid bulbs extending to the origins of the ICAs which were not significant stenoses. Postural symptoms were induced by standing the patient up rapidly and HMPAO was administered at the same time. A SPECT scan of the brain was performed. Quantitative analysis showed a left to right decrease of 10.8% in the temporo-occipital area, 5.6% in the temporo-parietal area and 2.5% in the cerebellar and parietal areas. Images revealed moderately reduced tracer concentration in the left half of the cerebellum and the left occipital region extending as far forward as the temporo-parietal region A repeat HMPAO SPECT scan without stress was normal. This would appear to indicate reversible ischaemia in the left posterior region, and is consistent with the reported symptoms. This case illustrates the usefulness of HMPAO in the diagnosis of reversible cerebral ischaemia

  18. Statistical parametric mapping of Tc-99m HMPAO SPECT cerebral perfusion in the normal elderly

    International Nuclear Information System (INIS)

    Turlakow, A.; Scott, A.M.; Berlangieri, S.U.; Sonkila, C.; Wardill, T.D.; Crowley, K.; Abbott, D.; Egan, G.F.; McKay, W.J.; Hughes, A.

    1998-01-01

    Full text: The clinical value of Tc-99m HMPAO SPECT cerebral blood flow studies in cognitive and neuropsychiatric disorders has been well described. Currently, interpretation of these studies relies on qualitative or semi- quantitative techniques. The aim of our study is to generate statistical measures of regional cerebral perfusion in the normal elderly using statistical parametric mapping (Friston et al, Wellcome Department of Cognitive Neurology, London, UK) in order to facilitate the objective analysis of cerebral blood flow studies in patient groups. A cohort of 20 healthy, elderly volunteers, aged 68 to 81 years, was prospectively selected on the basis of normal physical examination and neuropsychological testing. Subjects with risk factors, or a history of cognitive impairment were excluded from our study group. All volunteers underwent SPECT cerebral blood flow imaging, 30 minutes following the administration of 370 MBq Tc-99m HMPAO, on a Trionix Triad XLT triple-headed scanner (Trionix Research Laboratory Twinsburg, OH) using high resolution, fan-beam collimators resulting in a system resolution of 10 mm full width at half-maximum (FWHM). The SPECT cerebral blood flow studies were analysed using statistical parametric mapping (SPM) software specifically developed for the routine statistical analysis of functional neuroimaging data. The SPECT images were coregistered with each individual's T1-weighted MR volume brain scan and spatially normalized to standardised Talairach space. Using SPM, these data were analyzed for differences in interhemispheric regional cerebral blood flow. Significant asymmetry of cerebral perfusion was detected in the pre-central gyrus at the 95th percentile. In conclusion, the interpretation of cerebral blood flow studies in the elderly should take into account the statistically significant asymmetry in interhemispheric pre-central cortical blood flow. In the future, clinical studies will be compared to statistical data sets in age

  19. Statistical parametric mapping of Tc-99m HMPAO SPECT cerebral perfusion in the normal elderly

    Energy Technology Data Exchange (ETDEWEB)

    Turlakow, A.; Scott, A.M.; Berlangieri, S.U.; Sonkila, C.; Wardill, T.D.; Crowley, K.; Abbott, D.; Egan, G.F.; McKay, W.J.; Hughes, A. [Austin and Repatriation Medical Centre, Heidelberg, VIC (Australia). Departments of Nuclear Medicine and Centre for PET Neurology and Clinical Neuropsychology

    1998-06-01

    Full text: The clinical value of Tc-99m HMPAO SPECT cerebral blood flow studies in cognitive and neuropsychiatric disorders has been well described. Currently, interpretation of these studies relies on qualitative or semi- quantitative techniques. The aim of our study is to generate statistical measures of regional cerebral perfusion in the normal elderly using statistical parametric mapping (Friston et al, Wellcome Department of Cognitive Neurology, London, UK) in order to facilitate the objective analysis of cerebral blood flow studies in patient groups. A cohort of 20 healthy, elderly volunteers, aged 68 to 81 years, was prospectively selected on the basis of normal physical examination and neuropsychological testing. Subjects with risk factors, or a history of cognitive impairment were excluded from our study group. All volunteers underwent SPECT cerebral blood flow imaging, 30 minutes following the administration of 370 MBq Tc-99m HMPAO, on a Trionix Triad XLT triple-headed scanner (Trionix Research Laboratory Twinsburg, OH) using high resolution, fan-beam collimators resulting in a system resolution of 10 mm full width at half-maximum (FWHM). The SPECT cerebral blood flow studies were analysed using statistical parametric mapping (SPM) software specifically developed for the routine statistical analysis of functional neuroimaging data. The SPECT images were coregistered with each individual`s T1-weighted MR volume brain scan and spatially normalized to standardised Talairach space. Using SPM, these data were analyzed for differences in interhemispheric regional cerebral blood flow. Significant asymmetry of cerebral perfusion was detected in the pre-central gyrus at the 95th percentile. In conclusion, the interpretation of cerebral blood flow studies in the elderly should take into account the statistically significant asymmetry in interhemispheric pre-central cortical blood flow. In the future, clinical studies will be compared to statistical data sets in age

  20. Changes of rCBF 99mTc-HMPAO SPECT in a selected disorders

    International Nuclear Information System (INIS)

    Junik, R.

    2003-01-01

    With single photon emission computer tomography (SPECT) and HMPAO a noninvasive examination of regional cerebral blood flow can be performed (rCBF). The purpose of the SPECT examinations was to define the location and magnitude of blood flow disorder in selected diseases and the assessment of the results as complementary to morphological tests CT and MRI or functional tests, such as EEG. The examinations were carried out in 455 patients: 91 - patients with depression, 29 - congenital hypothyroidism, 66 - migraine, 34 - epilepsy, 6 - Landau-Kleffner syndrome, 20 - Alzheimer disease, 55 - with suspected Alzheimer disease, 105 - cerebral stroke, and 48 - transient cerebral ischemia. The control group comprised of 26 subjects. The SPECT method was used to perform examinations. The images were evaluated based on semiquantitative method. The asymmetry of activity and activity referred to the referential region were measured using symmetrical ROIs localized in hypoperfusion foci. The differences in perfusion in symmetric locations exceeding 10% were considered abnormal. During the depression stage, in patients with depression, a decrease of rCBF occurred. Regression of depression results in an increase of rCBF almost in the entire cerebrum. In patients with depression, SPECT examination is a useful method to monitor course of a disease and to objectively verify the results of treatment. 2. Disorders of rCBF, a decrease and/or asymmetry, occurred in patients with congenital hypothyroidism, migraine, and epilepsy. 3. There is a relation between patterns of cerebral perfusion in stroke, visible in SPECT image, and an extent and intensity of cerebral ischemia. (author)

  1. 99mTc-ECD SPECT study in dementia and aphasia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi

    1993-01-01

    We studied clinical significance of 99m Tc-L,L,-ethyl cysteine dimer ( 99m Tc-ECD) SPECT study in dementia and aphasia, and compared it with 99m Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in 99m Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in 99m Tc-HMPAO SPECT. The count rate ratios in 99m Tc-ECD and 99m Tc-HMPAO SPECT were correlated well with each other, and the contrast of the 99m Tc-ECD SPECT image was equivalent or slightly higher as compared with 99m Tc-HMPAO. Therefore, 99m Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author)

  2. Diagnostic performance of Tc-99m HMPAO SPECT for early and late onset Alzheimer's disease. A clinical evaluation of linearization correction

    International Nuclear Information System (INIS)

    Mitsumoto, Tatsuya; Sakaguchi, Yuichi; Morishita, Junji; Sasaki, Masayuki; Ohya, Nobuyoshi; Abe, Koichiro; Ichimiya, Atsushi; Kiyota, Aya

    2009-01-01

    This study examined the influence of linearization correction (LC) on brain perfusion single-photon emission computed tomography (SPECT) for the diagnosis of Alzheimer's disease (AD). The early onset group (<65 years old) consisted of 10 patients with AD, and the late onset group (≥65 years old) of 13 patients with AD. Age-matched controls included seven younger and seven older normal volunteers. Tc-99m hexamethyl propyleneamine oxine (HMPAO) SPECT images were reconstructed with or without LC [LC (+) or LC (-)] and a statistical analysis was performed using a three-dimensional stereotactic surface projection (3D-SSP). In addition, a fully automatic diagnostic system was developed, which calculated the proportion of the number of abnormal pixels in the superior and inferior parietal lobule, as well as in the precuneus and posterior cingulate gyrus. The areas under the receiver-operating characteristic curve (AUCs) of the early onset group for conventional axial SPECT images, SPECT+3D-SSP images and the fully automatic diagnostic system were 0.71, 0.88, and 0.92 in LC (-) and 0.67, 0.85, and 0.91 in LC (+), respectively. The AUCs of the late onset group were 0.50, 0.61, and 0.79 in LC (-) and 0.49, 0.67, and 0.85 in LC (+), respectively. LC on Tc-99m HMPAO SPECT did not significantly influence the diagnostic performance for differentiating between AD and normal controls in either early or late onset AD. Further examination with individuals suffering from very mild dementia is, therefore, expected to elucidate the effect of LC on minimally hypoperfused areas. (author)

  3. Role of SPECT (HM-PAO, Tc99mRc) and ultrasound (TCD) in the instrumental diagnostic approach to the comprehension of reversible ischemic symptoms

    International Nuclear Information System (INIS)

    Liboni, W.; Baggiore, P.; Chianale, G.; Marta, G.; Castellano, G.; Cornaglia, G.

    1989-01-01

    The relation between variations of cerebral and acute neurologic events, followed by partial or total recovery, has been investigated with SPECT HM-PAO and with ultrasound (TRANSCRANIAL DOPPLER). (H.W.). 3 refs.; 2 figs.; 2 tabs

  4. Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

    Science.gov (United States)

    Dierckx, R A; Saerens, J; De Deyn, P P; Verslegers, W; Marien, P; Vandevivere, J

    1991-08-01

    A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

  5. Surface and volume three-dimensional displays of Tc-99m HMPAO brain SPECT images in stroke patients with three-head gamma camera

    International Nuclear Information System (INIS)

    Shih, W.J.; Slevin, J.T.; Schleenbaker, R.E.; Mills, B.J.; Magoun, S.L.; Ryo, U.Y.

    1991-01-01

    This paper evaluates volume and surface 3D displays in Tc-99m HMPAO brain SPECT imaging in stroke patients. Using a triple-head gamma camera interfaced with a 64-bit supercomputer, 20 patients with stroke were studied. Each patient was imaged 30-60 minutes after an intravenous injection of 20 mCi of Tc-99m HMPAO. SPECT images as well as planar images were routinely obtained; volume and surface 3D display then proceeded, with the process requiring 5-10 minutes. Volume and surface 3D displays show the brain from all angles; thus the location and extension of lesion(s) in the brain are much easier to appreciate. While a cerebral lesion(s) was more clearly delineated by surface 3D imaging, crossed cerebellar diaschisis in seven patients was clearly exhibited with volume 3D but not with surface 3D imaging. Volume and surface 3D displays enhance continuity of structures and understanding of spatial relationships

  6. Differences of Tc-99m HMPAO SPECT imaging in the early stage of subcortical vascular dementia compared with Alzheimer's disease

    International Nuclear Information System (INIS)

    Park, Kyung Won; Kang, Do Young; Park, Min Jeong; Cheon, Sang Myung; Cha, Jae Kwan; Kim, Sang Ho; Kim, Jae Woo

    2007-01-01

    The aim of this study is to assess the specific patterns of regional cerebral blood flow (rCBF) in patients with the early stage of subcortical vascular dementia (SVaD) and Alzheimer's disease (AD) using Tc-99m HMPAO SPECT, and to compare the differences between the two conditions. Sixteen SVaD, 46 AD and 12 control subjects participated in this study. We included the patients with SVaD and AD according to NINCDS-ADRDA and NINDS-AIREN criteria. They were all matched for age, education and clinical dementia rating scores. Three groups were evaluated by Tc-99m HMPAO SPECT using statistical parametric mapping (SPM) for measuring rCBF. The SPECT data of patients with SVaD and AD were compared with those of normal control subjects and then compared with each other. SPM analysis of the SPECT image showed significant perfusion deficits on the right temporal region and thalamus, left insula and superior temporal gyrus, both cingulate gyri and frontal subgyri in patients with SVaD and on the left supramarginal gyrus, superior temporal gyrus, postcentral gyrus and inferior parietal lobule, right fugiform gyrus and both cingulate gyri in AD compared with control subjects (uncorrected ρ < 0.01). SVaD patients revealed significant hypoperfusion in the right parahippocampal gyrus with cingulated gyrus, left insula and both frontal subgyral regions compared with AD (uncorrected ρ < 0.01). Our study shows characteristic and different pattern of perfusion deficits in patients with SVaD and AD, and these results may be helpful to discriminate the two conditions in the early stage of illness

  7. [sup 99m]Tc-ECD SPECT study in dementia and aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1993-09-01

    We studied clinical significance of [sup 99m]Tc-L,L,-ethyl cysteine dimer ([sup 99m]Tc-ECD) SPECT study in dementia and aphasia, and compared it with [sup 99m]Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in [sup 99m]Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in [sup 99m]Tc-HMPAO SPECT. The count rate ratios in [sup 99m]Tc-ECD and [sup 99m]Tc-HMPAO SPECT were correlated well with each other, and the contrast of the [sup 99m]Tc-ECD SPECT image was equivalent or slightly higher as compared with [sup 99m]Tc-HMPAO. Therefore, [sup 99m]Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author).

  8. Computer-assisted superimposition of magnetic resonance and high-resolution technetium-99m-HMPAO and thallium-201 SPECT images of the brain

    International Nuclear Information System (INIS)

    Holman, B.L.; Zimmerman, R.E.; Johnson, K.A.; Carvalho, P.A.; Schwartz, R.B.; Loeffler, J.S.; Alexander, E.; Pelizzari, C.A.; Chen, G.T.

    1991-01-01

    A method for registering three-dimensional CT, MR, and PET data sets that require no special patient immobilization or other precise positioning measures was adapted to high-resolution SPECT and MRI and was applied in 14 subjects [five normal volunteers, four patients with dementia (Alzheimer's disease), two patients with recurrent glioblastoma, and three patients with focal lesions (stroke, arachnoid cyst and head trauma)]. T2-weighted axial magnetic resonance images and transaxial 99mTc-HMPAO and 201Tl images acquired with an annular gamma camera were merged using an objective registration (translation, rotation and rescaling) program. In the normal subjects and patients with dementia and focal lesions, focal areas of high uptake corresponded to gray matter structures. Focal lesions observed on MRI corresponded to perfusion defects on SPECT. In the patients who had undergone surgical resection of glioblastoma followed by interstitial brachytherapy, increased 201Tl corresponding to recurrent tumor could be localized from the superimposed images. The method was evaluated by measuring the residuals in all subjects and translational errors due to superimposition of deep structures in the 12 subjects with normal thalamic anatomy and 99mTc-HMPAO uptake. This method for superimposing magnetic resonance and high-resolution SPECT images of the brain is a useful technique for correlating regional function with brain anatomy

  9. Mismatched uptake of Tc-99m-ECD and Tc-99m-HMPAO in subacute cerebral infarction: Tc-99m-ECD for viability and Tc-99m-HMPAO for flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. S.; Hyun, I. Y.; Kim, S. K. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)] [and others

    1997-07-01

    Tc-99m-HMPAO reflects tissue perfusion but Tc-99m-ECD uptake is affected by tissue viability in addition to tissue perfusion which the varied state of cellular retention of Tc-99m-ECD reflects. Luxuriously perfused area on Tc-99m-HMPAO SPECT implies that this cortex was already reperfused either spontaneously or after thrombolysis and that accompanied paralysis of vascular reactivity in those zones warms progressive deterioration. We tried to find out if we can use sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT to reveal cortical perfusion and severity and range of risky areas of cerbral cortex despite reperfusion in sub-acute infarction. In 13 patients (M ; F =7 : 6, mean age 57 (range: 26-84)) with cortical (n=12) and basal ganglia infarction (1), we performed sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT at the same position. At first, 555 MBq of Tc-99m-ECD was injected and imaged and then 1110 MBq of Tc-99m-HMPAO was injected again and imaged with the patients in situ, and the first image (Tc-99m-ECD) and the subtracted image (2nd- 1st : Tc-99m-HMPAO) were compared slice by slice. Study was done from 3 days to 31 days (16{+-}9) after ictus. Tc-99m-ECD uptake was always less than or equal to Tc-99m-HMPAO uptake at the lesion in all cases. Luxury perfusion was prominent in four patients. Mismatched uptake was found in 10 patients. Severity of mismatch showed diverse spectrum and was ranged from total middle cerebral artery territory (1 case) to peripheral thin zones around infarction (2 cases). The other 7 showed intermediate amount of tissues with mismatch , i.e., Tc-99m-ECD defects where Tc-99m-HMPAO uptake is in part increased, normal or decreased. Upon discharge, patients having more uptake with Tc-99m-ECD predicted improvement. Patients having mismatched uptake went dichotomous way. In conclusion, Tc-99m-ECD/Tc-99m-HMPAO sequential SPECT is feasible and reveal both tissue perfusion (Tc-99m-HMPAO ) and discrepant Tc-99m-ECD uptake probably reflecting viability in acute

  10. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia; Measurement of cerebral blood volume (CBV) with sup 99m Tc-RBC SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo (Hokkaido Neurosurgical Memorial Hospital (Japan)); Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi

    1990-03-01

    To evaluate the efficacy of tests for selecting patients with hemodynamic compromise, measurement of cerebral blood volume (CBV) with {sup 99m}Tc-RBC single photon emission computed tomography (SPECT) was performed in thirteen patients with occlusive cerebrovascular disease, and was compared with results obtained by {sup 133}Xe SPECT and acetazolamide (Diamox) test. All patients in our study suffered TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery, although plain CT scan or MRI revealed no or, if any, only localized infarcted lesions. Regional cerebral blood volume (rCBV) was measured with {sup 99m}Tc-RBC SPECT and regional cerebral blood flow (rCBF) was measured with {sup 133}Xe SPECT before and after intravenous injection of 10 - 12 mg/kg acetazolamide (Diamox). Our results suggest that the ipsilateral rCBV/rCBF (mean transit time) is a more sensitive index of the cerebral perfusion reserve than the use of only rCBV or rCBF of the ipsilateral hemisphere. Also, the ipsilateral rCBV/rCBF is significantly correlated (r= -0.72) with the Diamox reactivity of rCBF, which is considered to represent the cerebral vasodilatory capacity in patients with chronic cerebral ischemia. Postoperative SPECT study revealed remarkable improvement of ipsilateral rCBV/rCBF and Diamox reactivity in four patients who underwent EC/IC bypass surgery to improve the hemodynamic compromise. In conclusion, our results suggest that the measurement of rCBV/rCBF with {sup 133}Xe SPECT and {sup 99m}Tc-RBC SPECT is useful for detecting the hemodynamic compromise in patients with occlusive cerebrovascular disease. (author).

  11. Memory functions and rCBF-99mTc-HMPAO-SPECT: Developing diagnostics in Alzheimer's Disease

    International Nuclear Information System (INIS)

    Sundstroem, T.; Riklund Ahlstroem, K.; Elgh, E.; Naesman, B.; Nyberg, L.

    2002-01-01

    Alzheimer's disease (AD) is a primary degenerative disease of the brain. The prevalence increases with age with devastating consequences for the individual and for the society. The aim of this study was to evaluate if patients with early AD show an altered regional cerebral blood flow (rCBF) compared to control persons. The aim was furthermore to investigate the correlation between rCBF in sub-lobar volumes of the brain and performance on memory tests. Memory tests were chosen to evaluate episodic and semantic memory. Fourteen patients (75.2±8.8 yrs) with early AD, and 15 control persons (71.4±3.2 yrs) were included. rCBF measurements with single photon emission computerized tomography (SPECT) using 99m Tc-hexamethyl propylenamine oxime (HMPAO) were performed. The rCBF- 99m Tc-HMPAO-SPECT images were spatially transformed to fit a brain atlas and normalized for differences in rCBF (Computerized Brain Atlas software). Cortical and sub-cortical volumes of interests (VOI) were analyzed and compared. Compared to the controls, AD-patients showed a significantly lower rCBF ratio in temporoparietal regions including left hippocampus. The diagnostic sensitivity and specificity for AD were high in temporoparietal regions. AD-patients had significantly reduced performance on semantic and, in particular, episodic memory tests compared to age matched normative data, and their performance on several episodic tests correlated with rCBF ratios in parietal and temporal regions including left hippocampus. The correlation between rCBF ratio and level of episodic memory performance suggests that abnormalities in rCBF pattern underlie impaired episodic memory functioning in AD

  12. Quantitative 123I IMP and 99mTc HMPAO imaging in the dog following cocaine administration

    International Nuclear Information System (INIS)

    Susskind, Herbert; Weber, David A.; Ivanovic, Marija; Wong, Christopher T.C.; Haan, Constance E. de; Gavin, Patrick R.

    1996-01-01

    SPECT and associated imaging procedures were used in beagle dogs to evaluate the uptake, distribution, and clearance properties of i.v.-injected 123 I IMP (IMP) and 99m Tc HMPAO (HMPAO) in the brain, lungs, liver, and kidneys; (2) quantify the acute effects (after 15 sec) of very low doses (0.5 or 1.0 mg/kg) cocaine on the kinetics and localization properties of IMP and HMPAO; and (3) evaluate comparative imaging properties of IMP and HMPAO for measuring regional cerebral blood flow (rCBF). Regional and global uptake and localization of IMP or HMPAO were evaluated in control studies using dynamic planar (0-30 min) and SPECT imaging (at 35 min). The regional distribution properties of IMP and HMPAO in the brain were estimated from regions of interest (ROIs) drawn around anatomic structures on MR slices and manually registered with corresponding SPECT slices. Cocaine significantly reduced the 30-min IMP uptake in the brain and lungs by ∼15%, but only slightly changed HMPAO uptake in the brain and other organs. In the control studies, the respective uptakes of IMP in the brain and lungs were 9 and 39% greater (p < 0.01) than those of HMPAO. In control SPECT studies, the highest uptake of IMP was observed in the thalamus and progressively less activity was observed in the parietal lobe, frontal lobe, cerebellum, occipital lobe, and entire brain; activity in the olfactory bulb was lower than in all other regions. Cocaine reduced IMP uptake in the cerebellum (p < 0.01), occipital lobe (p < 0.01), and entire brain (p < 0.05). IMP uptake (cpm/pixel-mCi) in the different brain regions was 1.3 to 2.1 times greater than that of HMPAO (p < 0.001). HMPAO uptake was more homogeneous throughout the gray matter of the brain; no significant uptake differences were observed among flagged regions. Results indicate that single, acute doses of cocaine, 0.5 and 1.0 mg/kg, significantly altered the uptake and localization properties of IMP in the dog's brain, lungs, liver, and kidneys

  13. Differences of Tc-99m HMPAO SPECT imaging in the early stage of subcortical vascular dementia compared with Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Won; Kang, Do Young; Park, Min Jeong; Cheon, Sang Myung; Cha, Jae Kwan; Kim, Sang Ho; Kim, Jae Woo [College of Medicine, Dong-A University, Busan (Korea, Republic of)

    2007-12-15

    The aim of this study is to assess the specific patterns of regional cerebral blood flow (rCBF) in patients with the early stage of subcortical vascular dementia (SVaD) and Alzheimer's disease (AD) using Tc-99m HMPAO SPECT, and to compare the differences between the two conditions. Sixteen SVaD, 46 AD and 12 control subjects participated in this study. We included the patients with SVaD and AD according to NINCDS-ADRDA and NINDS-AIREN criteria. They were all matched for age, education and clinical dementia rating scores. Three groups were evaluated by Tc-99m HMPAO SPECT using statistical parametric mapping (SPM) for measuring rCBF. The SPECT data of patients with SVaD and AD were compared with those of normal control subjects and then compared with each other. SPM analysis of the SPECT image showed significant perfusion deficits on the right temporal region and thalamus, left insula and superior temporal gyrus, both cingulate gyri and frontal subgyri in patients with SVaD and on the left supramarginal gyrus, superior temporal gyrus, postcentral gyrus and inferior parietal lobule, right fugiform gyrus and both cingulate gyri in AD compared with control subjects (uncorrected {rho} < 0.01). SVaD patients revealed significant hypoperfusion in the right parahippocampal gyrus with cingulated gyrus, left insula and both frontal subgyral regions compared with AD (uncorrected {rho} < 0.01). Our study shows characteristic and different pattern of perfusion deficits in patients with SVaD and AD, and these results may be helpful to discriminate the two conditions in the early stage of illness.

  14. Tc-99m-bicisate (ECD)-brain-SPECT in rapidly progressive dementia; Hirn-SPECT mit Tc-99m-Bicisat (ECD) bei rasch progredientem dementiellen Syndrom

    Energy Technology Data Exchange (ETDEWEB)

    Marienhagen, J.; Eilles, C. [Regensburg Univ. (Germany). Abt. fuer Nuklearmedizin; Weingaertner, U.; Blaha, L. [Bezirkskrankenhaus Mainkofen (Germany). Psychiatrische Klinik; Zerr, I.; Poser, S. [Goettingen Univ. (Germany). Klinik und Poliklinik fuer Neurologie

    1999-07-01

    We present a 61-year-old male patient with progressive dementia. A brain SPECT with Tc-99m-bicisate was performed for confirmation of clinically suspected Alzheimer-dementia. At the time of the SPECT-investigation marked apraxia and aphasia besides severe dementia were present. Electrophysiological as well as anatomical neuroimaging findings showed non-diagnostic alterations. SPECT revealed distinct perfusion defects, which made Alzheimer Dementia unlikely. The further course of the patient was determined by rapidly progressive deterioration with development of akinetic mutism. Thereafter, increased levels of neuron-specific enolase as well as 14-3-3 proteins were found in the cerebro-spinal fluid (CSF). The patient finally died with signs of cerebral decortication. Due to the clinical course and the CSF-findings the patient's final diagnosis was Creutzfeld-Jakob-disease, nevertheless no autopsy was performed. The presented case report underscores the clinical utility of perfusion brain SPECT in the differential diagnosis of dementias. (orig.) [German] Wir berichten ueber einen 61jaehrigen Patienten mit progredientem dementiellen Syndrom, der unter der Verdachtsdiagnose einer Demenz vom Alzheimer-Typ (DAT) zur Hirn-SPECT-Untersuchung mit TC-99m-Bicisat (ECD) vorgestellt wurde. Zum Untersuchungszeitpunkt bestanden neben dem Vollbild einer Demenz eine ausgepraegte Apraxie und Aphasie bei unspezifischen Veraenderungen im EEG sowie der neuroradiologischen Bildgebung. In der Hirn-SPECT-Untersuchung fanden sich fuer eine DAT untypische ausgedehnte, vorwiegend rechtshemisphaerische Perfusionsstoerungen. Im weiteren Verlauf rasche Progredienz des Krankheitsbildes mit Entwicklung eines akinetischen Mutismus sowie Nachweis erhoehter Werte der neuronspezifischen Enolase und des 14-3-3-Proteins im Liquor. Der Patient verstarb schliesslich unter dem Bild einer Decortication. Aufgrund des klinischen Verlaufs sowie der Liquorbefunde wurde, da eine autoptische Befundsicherung

  15. HMPAO-SPECT in dementia of the Alzheimer type and major depression with memory impairment

    International Nuclear Information System (INIS)

    Gruenwald, F.; Horn, R.; Rieker, O.; Klemm, E.; Menzel, C.; Moeller, H.J.; Biersack, H.J.

    1993-01-01

    The aim of the present study was to see whether HMPAO-SPECT may contribute to the differentiation between dementia of the Alzheimer type (DAT) and major depression (MD). The results in 77 patients with memory impairment were evaluated. 48 patients suffered from DAT and 29 from MD. Initially, the defects in SPECT imaging were attributed to a cerebral region and the degree of decrease was evaluated (-1/-2/-3). Thereafter, the results were classified by 7 categories. In some of these categories an accumulation of cases of either DAT or MD was found. 35% of the patients suffering from DAT had bilateral defects with distinct (>-1) parietal/parietotemporal hypoperfusions, but no patient with MD showed this perfusion pattern. 62% of the patients with MD had unilateral defects but only 31% of the patients with DAT. The present study demonstrates that only 35% of all patients suffering from DAT show a perfusion pattern, thought earlier as ''pathognomonic'' for this disease. This perfusion pattern - if it exists - may be used as a safe criterion to exclude MD. Beyond that no clearcut (''specific'') perfusion pattern may be recognized but unilateral defects point to MD. (orig.) [de

  16. Decreased cerebral blood flow and prognosis of Alzheimer's disease. A multicenter HMPAO-SPECT study

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hashikawa, Kazuo; Fukuyama, Hidenao

    2007-01-01

    The purpose of this study was to determine the usefulness of brain perfusion single photon emission computed tomography (SPECT) for evaluating the severity and progression of Alzheimer's disease (AD). Eighty-four AD patients were included. At entry, 99m Tc-HMPAO-SPECT, the Mini Mental State Examination (MMSE), Mental Function Impairment Scale (MENFIS), and the Raven Colored Progression Matrix (RCPM) were performed for all 84 patients. During the follow-up periods, two individual MMSE evaluations in 34 patients, two MENFIS evaluations in 30 patients, and two RCPM evaluations in 20 patients were performed. Based on the regions of decreased cerebral blood flow demonstrated on three-dimensional stereotactic surface projection (3D-SSP) images of SPECT, the cases were classified as type A (no decrease), type B (decreased blood flow in the parietal or temporal lobe), type C (decreased blood flow in the frontal lobe and parietal or temporal lobe), type Pc (decreased blood flow in posterior cingulate gyrus only), and ''other types''. The types of decreased blood flow, scores on neuropsychological evaluations, and symptom progression were analyzed. The MENFIS, MMSE, and RCPM scores were poorest in type C patients at entry. The degree of decrease of these scores during the follow-up periods was also greatest in type C. The greatest difference between patients with and without rapid progression in SPECT data of the mild AD patients (MMSE score≥24) was in the frontal lobe. Decreased blood flow in the frontal lobe of AD patients is correlated not only with reduced cognitive function at the time of the evaluation but with rapid progression in the subsequent clinical course. (author)

  17. Age-related changes in brain perfusion of normal subjects detected by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Krausz, Y.; Karger, H.; Chisin, R.; Bonne, O.; Gorfine, M.; Lerer, B.

    1998-01-01

    Previous functional imaging data generally show impairment in global cerebral blood flow (CBF) with age. Conflicting data, however, concerning age-related changes in regional CBF (rCBF) have been reported. We examined the relative rCBF in a sample of healthy subjects of various ages, to define and localize any age-related CBF reduction. Twenty-seven healthy subjects (17 male, 10 female; mean age 49 ± 15, range 26-71, median 47 years) were studied by 99m Tc-HMPAO brain SPECT. The younger age group consisted of subjects below, the older group above 47 years of age, respectively. Analysis was performed by applying three preformed templates, each containing delineated regions of interest (ROIs), to three transaxial brain slices at approximately 4, 6, and 7 cm above the orbitomeatal line (OML). The average number of counts for each ROI was normalized to mean uptake of the cerebellum and of the whole brain slice. Globally, 99m Tc-HMPAO uptake ratio normalized to cerebellum was significantly decreased in older subjects, affecting both hemispheres. A slight left-to-right asymmetry was observed in HMPAO uptake of the whole study group. It did not, however, change with age. Regionally, both cortical and subcortical structures of older subjects were involved: uptake ratio to cerebellum was significantly lower (after correction for multiple testing) in the left basal ganglia and in the left superior temporal, right frontal and bilateral occipital cortices at 4 cm above the OML. At 6 cm above the OML, reduced uptake ratios were identified in the left frontal and bilateral parietal areas. At 7 cm, reduced uptake was detected in the right frontal and left occipital cortices. Most of these differences were reduced when uptake was normalized to whole slice, whereas an increase in uptake ratios was observed in the cingulate cortex of the elderly. An inverse correlation between age and HMPAO uptake ratios normalized to cerebellum was observed in a number of brain regions. These

  18. Evaluation of hemodynamic effects of extracranial carotid stenoses by adenosine-induced vasodilatation in combination with 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Ussov, V.Yu.; Plotnikov, M.P.; Yaroshevsky, S.P.; Shipulin, V.M.; Sokolov, AA.

    1999-01-01

    Methods: Adenosine was evaluated in combination with 99mTc-HMPAO SPECT as an intravenous agent for the pharmacological stress-test of the regional cerebral blood flow (rCBF) in 12 patients with internal carotid artery (ICA) stenosis without neurologic deficit (8 subjects) or with minimal deficit (4 subjects). Also, the adenosine-induced effects on rCBF were correlated with the anatomic severity of ICA stenosis. Six normal age-matched volunteers served as control. Results: The rest 99mTc-HMPAO SPECT data did not reveal any significant interhemispheric asymmetry of perfusion either in ICA stenosis patients or in control subjects. No interhemispheric asymmetry was observed in control subjects during adenosine infusion either. In ICA stenosis the adenosine test did induce interhemispheric asymmetry of perfusion, which ranged between 0.73 and 0.96 when quantified as an interhemispheric ratio of 99mTc-HMPAO uptake. In 5 of the 12 patients with ICA stenosis, adenosine also elicited a short - term muscular weakness and/or skin paresthesia consistent with cerebral location of the related cortical zones in the stenosis - dependent hemisphere. No correlation was noted between the interhemispheric anatomic planimetric asymmetry of stenosis (as ratio of patent ICA vessel lumen areas) and perfusion asymmetry at rest. The planimetric asymmetry of stenosis correlated significantly with the adenosine-induced asymmetry of rCBF in ICA - dependent areas (r = 0.78, p < 0.02). The correlation could be observed beginning from the magnitude of 70-75% relatively to the cross-sectional area of the contralateral intact vessel, equivalent to 45-50% decrease in the arterial diameter as compared to the intact artery. Conclusion: Therefore, the conclusion can be drawn that adenosine as a potent cerebral vasodilatator may be employed as a challenging agent for functional tests of rCBF and that the adenosine test facilitates detection of the hemodynamic effects of ''minor'' stenoses. (author)

  19. 99mTc-HMPAO SPECT of the brain in mild to moderate traumatic brain injury patients: compared with CT--a prospective study.

    Science.gov (United States)

    Nedd, K; Sfakianakis, G; Ganz, W; Uricchio, B; Vernberg, D; Villanueva, P; Jabir, A M; Bartlett, J; Keena, J

    1993-01-01

    Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.

  20. Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Yamakami, Iwao; Yamaura, Akira; Isobe, Katsumi

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99m technetium-hexamethyl propyleneamine oxime (HMPAO). Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated: 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient. (author)

  1. A new prognostic index - leucocyte infiltration - in human cerebral infarcts by 99Tcm-HMPAO-labelled white blood cell brain SPECT

    International Nuclear Information System (INIS)

    Kao, C.H.; Wang, P.Y.; Wang, Y.L.; Chang, L.; Wang, S.J.; Yeh, S.H.

    1991-01-01

    Twenty-six patients with acute cerebral infarction were imaged by 99 Tc m -hexamethylpropylene-amine oxime (HMPAO)-labelled white blood cell brain (Tc-WBC) single photon emission computed tomography (SPECT). The regions of interest were equally placed in the whole hemispheres of both sides with summation of all transaxial slices in the Tc-WBC SPECT. The asymmetric indices (AI) were calculated as 200 [|(right -left)|/(right + left)]. Grouping of patients with cerebral infarction was based on activities of daily living (ADL) at outcome. The results showed that the poor outcome patient group had a higher AI of Tc-WBC than that of the other patients (13.0 ± 3.0 S.E.M. versus 5.4 ± 1.0 S.E.M., and P < 0.05 by Wilcoxon rank sum test). In conclusion, the Tc-WBC SPECT may be considered as a new prognostic index to predict patient outcome in human cerebral ischaemic infarctions consistent with newly established ischaemic injury theories. (author)

  2. Follow-up findings in regional cerebral blood flow (r-CBF)-SPECT in a case of idiopathic childhood hemidystonia. Functional neuroimaging and pathophysiological implications

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, A.; Aderbauer, J.; Segerer, H. [St. Hedwig Hospital, Regensburg (Germany). Dept. of Pediatrics; Marienhagen, J.; Bock, E.; Eilles, C. [Univ. Hospital, Regensburg (Germany). Dept. of Nuclear Medicine

    1999-05-01

    A 9 1/2-year-old girl suffered from intermitting tremor and jitteriness of her left hand and oral muscles every 4 to 6 weeks with long lasting episodes. Clinically myoclonias and dystonic positioning of the left arm, hand and facial muscles were seen. No evidence of trauma, infection or inborn errors of metabolism was found. Successful therapy with carbamazepine was initiated while L-DOPA failed. An ictal 99m-Tc-HMPAO-SPECT showed severe asymmetry with focal hyperperfusion of the contralateral right thalamus and basal ganglia as well as of the bifrontal cortex, whereas no anatomical lesions were found by MRI. In contrast, an interictally performed 99m-Tc-HMPAO SPECT showed hypoperfusion or the right thalamus and normalisation of the frontal perfusion under medical treatment. These 99m-Tc-HMPAO-SPECT findings may provide new insights into the localisation and pathophysiological pathways of idiopathic childhood dystonia. (orig.) [Deutsch] Ein 9 1/2jaehriges Maedchen litt an rezidivierenden, langdauernden Schueben von Tremor und Zittern der linken Hand und der perioralen Muskulatur links. Klinisch fanden sich eine dystone Haltung des linken Armes und unerschoepfliche Myoklonien des Armes, der Hand und der Gesichtsmuskulatur links. Trauma, Infektion oder ein Stoffwechseldefekt als Ursache lagen nicht vor. Ein Therapieversuch mit L-DOPA war erfolglos. Unter Gabe von Carbamazepin wurde Beschwerdefreiheit bleibend erreicht. Ein iktuales 99m-Tc-HMPAO-SPECT zeigte eine fokale Hyperperfusion des rechtsseitigen Thalamus und der Basalganglien, sowie des bifrontalen Kortex. Ein interiktuales 99m-Tc-HMPAOSPECT ergab dann eine deutliche Hypoperfusion des rechtseitigen Thalamus bei normalisierter Perfusion des bifrontalen Kortex. Eine kranielle Magnetresonanztomographie (MRI) ergab einen unauffaelligen Befund. Der Vergleich der iktualen und interiktualen Perfusionsverhaeltnisse weist auf neue pathophysiologische Zusammenhaenge bei idiopathischer kindlicher Dystonie hin. (orig.)

  3. SPECT-imaging of activity-dependent changes in regional cerebral blood flow induced by electrical and optogenetic self-stimulation in mice.

    Science.gov (United States)

    Kolodziej, Angela; Lippert, Michael; Angenstein, Frank; Neubert, Jenni; Pethe, Annette; Grosser, Oliver S; Amthauer, Holger; Schroeder, Ulrich H; Reymann, Klaus G; Scheich, Henning; Ohl, Frank W; Goldschmidt, Jürgen

    2014-12-01

    Electrical and optogenetic methods for brain stimulation are widely used in rodents for manipulating behavior and analyzing functional connectivities in neuronal circuits. High-resolution in vivo imaging of the global, brain-wide, activation patterns induced by these stimulations has remained challenging, in particular in awake behaving mice. We here mapped brain activation patterns in awake, intracranially self-stimulating mice using a novel protocol for single-photon emission computed tomography (SPECT) imaging of regional cerebral blood flow (rCBF). Mice were implanted with either electrodes for electrical stimulation of the medial forebrain bundle (mfb-microstim) or with optical fibers for blue-light stimulation of channelrhodopsin-2 expressing neurons in the ventral tegmental area (vta-optostim). After training for self-stimulation by current or light application, respectively, mice were implanted with jugular vein catheters and intravenously injected with the flow tracer 99m-technetium hexamethylpropyleneamine oxime (99mTc-HMPAO) during seven to ten minutes of intracranial self-stimulation or ongoing behavior without stimulation. The 99mTc-brain distributions were mapped in anesthetized animals after stimulation using multipinhole SPECT. Upon self-stimulation rCBF strongly increased at the electrode tip in mfb-microstim mice. In vta-optostim mice peak activations were found outside the stimulation site. Partly overlapping brain-wide networks of activations and deactivations were found in both groups. When testing all self-stimulating mice against all controls highly significant activations were found in the rostromedial nucleus accumbens shell. SPECT-imaging of rCBF using intravenous tracer-injection during ongoing behavior is a new tool for imaging regional brain activation patterns in awake behaving rodents providing higher spatial and temporal resolutions than 18F-2-fluoro-2-dexoyglucose positron emission tomography. Copyright © 2014 The Authors

  4. The need of appropriate brain SPECT templates for SPM comparisons

    International Nuclear Information System (INIS)

    Morbelli, S.; Altrinetti, V.; Piccardo, A.; Rodriguez, G.; Brugnolo, A.; Nobili, F.; Mignone, A.; Pupi, A.; Koulibaly, P.M.

    2008-01-01

    Statistical parametric mapping (SPM) is used worldwide to compare brain perfusion single photon emission computed tomography (SPECT) data. The default template within the SPM package used for SPECT image normalization includes images of a group of healthy subjects studied with 99m TcHMPAO. Since [ 99m Tc] HMPAO and [ 99m Tc] ECD have shown to distribute differently in SPECT studies, we formulated the hypothesis that comparing set of [ 99m Tc]ECD data normalized by means of a [ 99m Tc]HMPAO template may lead to incorrect results. A customized [ 99m Tc]ECD template was built with SPECT and magnetic resonance imaging (MRI) images of 22 neurologically healthy women. Then, two sets of subjects, i.e. a group of patients with very early Alzheimer's disease (eAD) and a matched control group, studied by means of [ 99m Tc]ECD SPECT, were chosen for comparisons. The same statistical approach (t-test between eAD patients and controls and correlation analysis between brain SPECT and a cognitive score) was applied twice, i.e. after normalization with either the default [ 99m Tc]HMPAO template or the customized [ 99m Tc]ECD template. In the comparison between eAD and controls, a cluster of difference in the posterior-cingulate gyrus of both hemispheres was only highlighted when using the customized [ 99m Tc]ECD template, but was missed when using the default [ 99m Tc]HMPAO template. In the correlation between brain perfusion and a cognitive score, the significant cluster was more significant and far more extended, also including the right superior temporal gyrus, using the customized [ 99m Tc]ECD template than using the default [ 99m Tc]HMPAO template. These data suggest the need of customized, radiopharmaceutical-matched SPECT templates to be used within the SPM package. The present customized [ 99m Tc]ECD template is now freely available on the web. (authors)

  5. Comparison of Tc-99m HM-PAO and I-123 IMP cerebral SPECT images in Alzheimer's disease and multi-infarct dementia

    Energy Technology Data Exchange (ETDEWEB)

    Gemmell, H G; Sharp, P F; Besson, J A.O.; Ebmeier, K P; Smith, F W

    1988-10-01

    SPECT images of the brain can be obtained using either /sup 123/I labelled amines or /sup 99m/Tc-hexamethylpropyleneamineoxime (HM-PAO). Both materials produce images which are blood flow dominated and so appear similar in normal subjects, although the respective mechanisms of uptake are not yet finally established. It seems likely, however, that the different mechanisms of uptake are responsible for recent reports of some differences seen in images obtained with the two types of agent in patients with cerebral pathology, mainly cerebrovascular disease. In this study, 12 demented patients, 6 with dementia of the Alzheimer type (DAT) and 6 with multi infarct dementia (MID), were imaged with /sup 123/I-isopropylamphetamine (IMP) and /sup 99m/Tc-HM-PAO and the images compared. Significantly more lesions were seen with IMP than HM-PAO (P < 0.02); out of a possible 120 sites, 41 lesions were seen with IMP compared to 28 with HM-PAO, 23 being seen with both agents. However, it is concluded that either agent can be used for the differential diagnosis of dementia, a task for which the new cerebral blood flow agents seem well suited.

  6. Discrepant 99mTc-ECD images of CBF in patients with subacute cerebral infarction. A comparison of CBF, CMRO2 and 99mTc-HMPAO imaging

    International Nuclear Information System (INIS)

    Shishido, Fumio; Uemura, Kazuo; Inugami, Atsushi; Ogawa, Toshihide; Fujita, Hideaki; Shimosegawa, Eku; Nagata, Ken.

    1995-01-01

    Three patients with subacute ischemic cerebral infarction examined by SPECT with 99m Tc-ECD and PET within the same day showed signs of luxury perfusion in the subacute phase, which is between 9 to 20 days after the onset. A 99m Tc-HMPAO SPECT study was also performed within 2 days of the ECD-SPECT study. ECD-SPECT images of three patients displayed a focal decreased uptake in the infarcted lesions, while in infarcted foci, there was almost equivalent or increased CBF compared to normal and unaffected areas, decreased CMRO 2 , and high HMPAO uptake. The ECD-SPECT results were similar to those of CMRO 2 rather than CBF, though the HMPAO-SPECT image was similar to that of CBF. In one patient, HMPAO images revealed hyperfixation of the tracer. In the chronic phase and in the acute phase before 5 days after the onset, there were no discrepancies among the ECD-SPECT, CBF, HMPAO-SPECT, and CMRO 2 images. These observations indicated that 99m Tc-ECD is a good indicator of damaged brain tissues in subacute ischemic infarction. They also suggested that 99m Tc-ECD is a potential agent with which to evaluate cerebral tissue viability in some pathological states of cerebrovascular disease. The characteristics may be suitable for confirming the effects of thrombolytic therapy in acute ischemia, because these conditions often show signs of luxury perfusion when the therapy is successful. (author)

  7. Clinical experience with Tc-99m HM-PAO high resolution SPECT of the brain in patients with cerebrovascular accidents

    International Nuclear Information System (INIS)

    Roo, M. de; Mortelmans, L.; Devos, P.; Verbruggen, A.; Wilms, G.; Carton, H.; Wils, V.; Bergh, R. van den

    1989-01-01

    In order to evaluate the diagnostic contribution of brain SPECT imaging with 99m Tc-HMPAO in cerebrovascular disease, we examined 92 stroke cases (144 lesions), 2 hematoma cases and 30 cases with transient neurologic symptoms. Abnormal tracer distribution is visible as zones of either hypoactivity or hyperactivity (border zone hyperemia or luxury perfusion). Remote vascularization changes could also be found (crossed cerebellar diaschisis or ipsilateral cortical perfusion reduction in thalamic or capsula interna lesions). Both X-ray CT and blood flow SPECT have comparable sensitivity in the exploaration of cerebral infarction, with detection in, respectively, 89,5% and 87,5% of the lesions. False negative scintitomographic images are frequently recorded in small lacunar infarcts within the basal ganglia and white matter (capsula interna). Some early infarcts and asymmetry of brain perfusion in patients with transient neurologic symptoms are frequently not detected by CT. An additional advantage of blood flow SPECT is its ability to visualize remote blood flow changes and the changing pattern of vascularization of ischemic lesions and their surrounding areas including hyperemia. (orig.)

  8. Clinical experience with Tc-99m HM-PAO high resolution SPECT of the brain in patients with cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Roo, M. de; Mortelmans, L.; Devos, P.; Verbruggen, A.; Wilms, G.; Carton, H.; Wils, V.; Bergh, R. van den

    1989-01-01

    In order to evaluate the diagnostic contribution of brain SPECT imaging with /sup 99m/Tc-HMPAO in cerebrovascular disease, we examined 92 stroke cases (144 lesions), 2 hematoma cases and 30 cases with transient neurologic symptoms. Abnormal tracer distribution is visible as zones of either hypoactivity or hyperactivity (border zone hyperemia or luxury perfusion). Remote vascularization changes could also be found (crossed cerebellar diaschisis or ipsilateral cortical perfusion reduction in thalamic or capsula interna lesions). Both X-ray CT and blood flow SPECT have comparable sensitivity in the exploaration of cerebral infarction, with detection in, respectively, 89,5% and 87,5% of the lesions. False negative scintitomographic images are frequently recorded in small lacunar infarcts within the basal ganglia and white matter (capsula interna). Some early infarcts and asymmetry of brain perfusion in patients with transient neurologic symptoms are frequently not detected by CT. An additional advantage of blood flow SPECT is its ability to visualize remote blood flow changes and the changing pattern of vascularization of ischemic lesions and their surrounding areas including hyperemia.

  9. Types of traumatic brain injury and regional cerebral blood flow assessed by [sup 99m]Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Iwao; Yamaura, Akira; Isobe, Katsumi [Chiba Univ. (Japan). School of Medicine

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with [sup 99m]technetium-hexamethyl propyleneamine oxime (HMPAO). Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated: (1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, (2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and (3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient. (author).

  10. Comparison of 99Tcsup(m) complexes (NEP-DADT, ME-NEP-DADT and HMPAO) with 123IAMP for brain SPECT imaging in dogs

    International Nuclear Information System (INIS)

    Bok, B.D.; Scheffel, U.; Goldfarb, H.W.; Burns, H.D.; Lever, S.Z.; Wong, D.F.; Bice, A.; Wagner, H.N. Jr.

    1987-01-01

    In this study we have compared brain uptake and blood clearance of 99 Tcsup(m)-N-ethylpiperi-dinediamino dithiol ( 99 Tcsup(m)-NEP DADT), its 4-methylated derivative ( 99 Tcsup(m)-Me-NEP-DADT) and 99 Tcsup(m)-hexamethyl-propylene-amine-oxime ( 99 Tcsup(m)-HMPAO) with that of N-isopropyl( 123 I)iodoamphetamine ( 123 IAMP) in two dogs. Single photon emission tomography (SPECT) was employed to measure brain accumulation and retention of the four radiopharmaceuticals. Cerebral uptake of the 99 Tcsup(m) complexes was lower than that of 123 IAMP. There was considerable extracerebral activity in the dog's head, especially in the olfactory and snout regions. Because of slow blood clearance, 99 Tcsup(m)-HMPAO showed high uptake in these regions. Brain uptake of 99 Tcsup(m)-HMPAO reached a plateau 5 to 10 min after intravenous injection and remained constant for the entire study period (1 h). 99 Tcsup(m)-NEP-DADT, on the other hand, showed significant clearance from the brain after reaching maximal uptake at 10 to 15 min after injection. However, brain imaging with these agents was possible during the first 20 min. (author)

  11. Brain perfusion SPECT in the mouse: normal pattern according to gender and age.

    Science.gov (United States)

    Apostolova, Ivayla; Wunder, Andreas; Dirnagl, Ulrich; Michel, Roger; Stemmer, Nina; Lukas, Mathias; Derlin, Thorsten; Gregor-Mamoudou, Betina; Goldschmidt, Jürgen; Brenner, Winfried; Buchert, Ralph

    2012-12-01

    Regional cerebral blood flow (rCBF) is a useful surrogate marker of neuronal activity and a parameter of primary interest in the diagnosis of many diseases. The increasing use of mouse models spawns the demand for in vivo measurement of rCBF in the mouse. Small animal SPECT provides excellent spatial resolution at adequate sensitivity and is therefore a promising tool for imaging the mouse brain. This study evaluates the feasibility of mouse brain perfusion SPECT and assesses the regional pattern of normal Tc-99m-HMPAO uptake and the impact of age and gender. Whole-brain kinetics was compared between Tc-99m-HMPAO and Tc-99m-ECD using rapid dynamic planar scans in 10 mice. Assessment of the regional uptake pattern was restricted to the more suitable tracer, HMPAO. Two HMPAO SPECTs were performed in 18 juvenile mice aged 7.5 ± 1.5weeks, and in the same animals at young adulthood, 19.1 ± 4.0 weeks (nanoSPECT/CTplus, general purpose mouse apertures: 1.2kcps/MBq, 0.7mm FWHM). The 3-D MRI Digital Atlas Database of an adult C57BL/6J mouse brain was used for region-of-interest (ROI) analysis. SPECT images were stereotactically normalized using SPM8 and a custom made, left-right symmetric HMPAO template in atlas space. For testing lateral asymmetry, each SPECT was left-right flipped prior to stereotactical normalization. Flipped and unflipped SPECTs were compared by paired testing. Peak brain uptake was similar for ECD and HMPAO: 1.8 ± 0.2 and 2.1 ± 0.6 %ID (p=0.357). Washout after the peak was much faster for ECD than for HMPAO: 24 ± 7min vs. 4.6 ± 1.7h (p=0.001). The general linear model for repeated measures with gender as an intersubject factor revealed an increase in relative HMPAO uptake with age in the neocortex (p=0.018) and the hippocampus (p=0.012). A decrease was detected in the midbrain (p=0.025). Lateral asymmetry, with HMPAO uptake larger in the left hemisphere, was detected primarily in the neocortex, both at juvenile age (asymmetry index AI=2.7 ± 1

  12. Imaging of mild traumatic brain injury using 57Co and 99mTc HMPAO SPECT as compared to other diagnostic procedures.

    Science.gov (United States)

    Audenaert, Kurt; Jansen, Hugo M L; Otte, Andreas; Peremans, Kathelijne; Vervaet, Myriam; Crombez, Roger; de Ridder, Leo; van Heeringen, Cees; Thirot, Joel; Dierckx, Rudi; Korf, Jaap

    2003-10-01

    Traumatic brain injury (TBI) is usually assessed with the Glasgow Coma Scale (GCS), CT and EEG. TBI can result from either the primary mechanical impact or secondary (ischemic) brain damage, in which calcium (Ca) plays a pivotal role. This study was undertaken to compare the applicability of SPECT using 57Co as a Ca-tracer in patients with mild traumatic brain injury. 8 patients with mild TBI (GCS 15) were clinically examined and studied with EEG, neuropsychological testing (NPT) and SPECT within 2 days post-TBI. After i.v.-administration of 37 MBq (1 mCi) 57Co (effective radiation dose 0.34 mSv x MBq(-1); 1.24 rem x mCi(-1); physical half-life 270 days, biological half-life 37.6 h), single-headed SPECT (12 h pi) was performed, consecutively followed by standard 925 MBq (25 mCi) Tc-99m HMPAO SPECT. In 6 of the 8 patients, baseline NPT and SPECT showed focal abnormalities in the affected frontal and temporal brain regions, which were in good topographical accordance. CT and EEG did not detect (structural) lesions in any of these cases. Single-headed 57Co-SPECT is able to show the site and extent of brain damage in patients with mild TBI, even in the absence of structural lesions. It may confirm and localize NPT findings. The predictive value of 57Co-SPECT should be assessed in larger patient series.

  13. Brain SPECT using dipyridamole for evaluation of vascular reserve

    International Nuclear Information System (INIS)

    Kim, Su Zy; Park, Chan Hee; Yoon, Soo Hwan; Pai, Moon Sun; Yoon, Suk Nam; Cho, Kyung Kee

    1997-01-01

    Baseline and stress brain SPECT studies using CO 2 inhalation, acetazolamide (Diamox R ) and adenosine administrations have been used in the evaluation of cerebral vascular reserve. Recently dipyridamole (Persantine R ) which is one of the pharmacologic myocardial perfusion SPECT agents as a potent vasodilator is suggested as another cerebral vasodilator. IV Diamox R is not available in Korea. Therefore, the purpose of our study was to evaluate dipyridamole in stress brain SPECT in patients with Moya Moya disease. Eight patients with angiographically proven Moya Moya disease were studied. Their ages ranged from 7 to 62 year old. There were 4 males and 4 females. Each patient had a baseline and persantine brain SPECT studies with 1 to 3 days' interval. Dipyridamole was given intravenously at a dose of 0.56 mg/kg over 4 minutes while watching vital signs such as blood pressure, heart rate, and electrocardiogram. Three minutes after the completion of the infusion, 99mTc-ECD (0.2 mCi/Ib body weight) was injected. Brain SPECT was performed 30 minutes later using a tripple head gamma camera equipped with LEHR collimators. A total of 128 projections with an acquisition time of 30 second per projection was obtained and reconstructed by filtered back projections without attenuation correction. The difference between the baseline and persantine studies was analysed by visual and semiquantitavely. During the infusion of persantine, heart rate, blood pressure and side effects such as headache, chest discomfort were similar to the persantine myocardial SPECT studies. Five of eight patients showed a significant decrease in rCBF on persantine brain SPECT in comparison to the baseline study. The remaining three revealed no significant change in rCBF. Our study suggests that the dipyridamole stress brain SPECT is feasible and useful in assessing cerebral blood flow reserve. However we need to evaluate more number of patients in the future

  14. The role of Tc-99m HMPAO brain perfusion SPECT in the psychiatric disability evaluation of patients with chronic traumatic brain injury

    Energy Technology Data Exchange (ETDEWEB)

    So, Young [Nuclear Medicne, Seoul National Univ., Seoul (Korea, Republic of); Lee, Kang Wook; Lee, Sun Woo; Ghi, Lek Sung; Song, Chang June [College of Medicine, Chungnam National Univ., Taejon (Korea, Republic of)

    2002-08-01

    We studied whether brain perfusion SPECT is useful in the psychiatric disability evaluation of patients with chronic traumatic brain injury (TBI). Sixty-nine patients (M:F=58:11, age 39 {+-} 14 years) who underwent Tc-99m HMPAO brain SPECT, brain MRI and neuropsychological (NP) tests during hospitalization in psychiatric wards for the psychiatric disability evaluation were included; the severity of injury was mild in 31, moderate in 17 and severe in 21. SPECT, MRI, NP tests were performed 6 {approx} 61 months (mean 23 months) post-injury. Diagnostic accuracy of SPECT and MRI to show hypoperfusion or abnormal signal intensity in patients with cognitive impairment represented by NP test results were compared. Forty-two patients were considered to have cognitive impairment on NP tests and 27 not. Brain SPECT showed 71% sensitivity and 85% specificity, while brain MRI showed 62% sensitivity and 93% specificity (p>0.05, McNemar test). SPECT found more cortical lesions and MRI was superior in detecting white matter lesions. sensitivity and specificity of 31 mild TBI patients were 45%, 90% for SPECT and 27%, 100% for MRI (p>0.05, McNemar test). Among 41 patients with normal brain MRI, SEPCT showed 63% sensitivity (50% for mild TBI) and 88% specificity (85% for malingerers). Brain SPECT has a supplementary role to neuropsychological tests in the psychiatric disability evaluation of chronic TBI patients by detecting more cortical lesions than MRI.

  15. The role of Tc-99m HMPAO brain perfusion SPECT in the psychiatric disability evaluation of patients with chronic traumatic brain injury

    International Nuclear Information System (INIS)

    So, Young; Lee, Kang Wook; Lee, Sun Woo; Ghi, Lek Sung; Song, Chang June

    2002-01-01

    We studied whether brain perfusion SPECT is useful in the psychiatric disability evaluation of patients with chronic traumatic brain injury (TBI). Sixty-nine patients (M:F=58:11, age 39 ± 14 years) who underwent Tc-99m HMPAO brain SPECT, brain MRI and neuropsychological (NP) tests during hospitalization in psychiatric wards for the psychiatric disability evaluation were included; the severity of injury was mild in 31, moderate in 17 and severe in 21. SPECT, MRI, NP tests were performed 6 ∼ 61 months (mean 23 months) post-injury. Diagnostic accuracy of SPECT and MRI to show hypoperfusion or abnormal signal intensity in patients with cognitive impairment represented by NP test results were compared. Forty-two patients were considered to have cognitive impairment on NP tests and 27 not. Brain SPECT showed 71% sensitivity and 85% specificity, while brain MRI showed 62% sensitivity and 93% specificity (p>0.05, McNemar test). SPECT found more cortical lesions and MRI was superior in detecting white matter lesions. sensitivity and specificity of 31 mild TBI patients were 45%, 90% for SPECT and 27%, 100% for MRI (p>0.05, McNemar test). Among 41 patients with normal brain MRI, SEPCT showed 63% sensitivity (50% for mild TBI) and 88% specificity (85% for malingerers). Brain SPECT has a supplementary role to neuropsychological tests in the psychiatric disability evaluation of chronic TBI patients by detecting more cortical lesions than MRI

  16. Noninvasive regional cerebral blood flow measurements at pre- and post-acetazolamide test using 99mTc-ECD

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Nakano, Seigo; Tanaka, Masaaki.

    1996-01-01

    A technique for serial noninvasive cerebral blood flow measurements at pre- and post-acetazolamide (Diamox) test was newly developed using 99m Tc-ECD without blood sampling. Baseline mean cerebral blood flow (mCBF) was measured from graphical analysis of time activity curves for brain and aortic arch obtained from radionuclide angiography by injection of 370-555 MBq 99m Tc-ECD. The first SPECT study was performed immediately after intravenous administration of 1 g of Diamox, then baseline regional cerebral blood flow (rCBF) was calculated using Lassen's correction algorithm. Immediately after the stop of the first SPECT study, additional 555-740 MBq of 99m Tc-ECD was administered, thereafter the second SPECT study was started. Post-Diamox SPECT images were obtained by subtraction of the first baseline images from the second images. Using Lassen's algorithm, post-Diamox mCBF was estimated from the baseline mCBF, the baseline mean SPECT counts, and post-Diamox mean SPECT counts corrected for administered dose and imaging time. Post-Diamox rCBF was obtained from the post-Diamox mCBF and the post-Diamox mean SPECT counts using Lassen's algorithm. Coefficient variation was shown 2.7% and 3.5%: mCBF and rCBF, respectively in test-retest results in six patients without Diamox administration. Nine demented patients without vascular disorders showed significant mCBF increase of 35.7% on the average by post-Diamox. In conclusion, this simplified method is practically useful for measuring CBF at pre- and post-Diamox test within short period of time without any blood sample. (author)

  17. Diamox-enhanced brain SPECT in cerebrovascular diseases

    International Nuclear Information System (INIS)

    Choi, Yun Young

    2007-01-01

    Acute event in cerebrovascular disease is the second most common cause of death in Korea following cancer, and it can also cause serious neurologic deficits. Understanding of perfusion status is important for clinical applications in management of patients with cerebrovascular diseases, and then the attacks of ischemic neurologic symptoms and the risk of acute events can be reduced. Therefore, the normal vascular anatomy of brain, various clinical applications of acetazolamide-enhanced brain perfusion SPECT, including meaning and role of assessment of vascular reserve in carotid stenosis before procedure, in pediatric Moyamoya disease before and after operation, in prediction of development of hyperperfusion syndrome before procedure, and in prediction of vasospasm and of prognosis in subarachnoid hemorrhage were reviewed in this paper

  18. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  19. Clinical value of scatter correction for interictal brain 99m Tc-HMPAO SPECT in mesial temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Sanchez Catasus, C.; Morales, L.; Aguila, A.

    2002-01-01

    Aim: It is well known that some patients with temporal lobe epilepsy (TLE) show normal perfusion during interictal SPECT study. The aim of this research was to evaluate if the scatter radiation has some influence on this kind of result. Materials and Methods: We studied 15 patients with TLE by clinical diagnosis and by video-EEG monitoring with surface electrodes (11 left TLE, 4 right TLE), which showed normal perfusion during interictal brain 99m Tc-HMPAO SPECT. The SPECT data were reconstructed by filtered backprojection without scatter correction (A). The same SPECT data were reconstructed after the projections were corrected by dual energy window method of scatter correction (B). Attenuation was corrected in all cases using first order Chang Method. For A and B images groups, cerebellum perfusion ratios were calculated on irregular regions of interest (ROI) drawn on anterior (ATL), lateral (LTL), mesial (MTL) and whole temporal lobe (WTL). To evaluate the influence of scatter radiation, the cerebellum perfusion ratios of each subject were compared with a normal database of 10 normal subjects, with and without scatter correction, using z-score analysis. Results: In group A, the z-score was less than 2 in all cases. In group B, the z-score was more than 2 in 6 cases, 4 in MTL (3 left, 1 right) and 2 in left LTL, which were coincident with the EEG localization. All images of group B showed better contrast than images of group A. Conclusions: These results suggest that scatter correction could improve the sensitivity of interictal brain SPECT to identify epileptic focus in patients with TLE

  20. Findings of 99mTc-HMPAO Regional Cerebral Blood Flow SPECT in a Case of Herpes Simplex Encephalitis

    International Nuclear Information System (INIS)

    Ahn, Myeong Im; Lee, Sung Yong; Kim, Jong Woo; Bahk, Yong Whee

    1989-01-01

    Herpes simplex encephalitis (HSE) is one of the fulminant necrotizing, often fatal sporadic form of the encephalitis caused by herpes simplex type I virus. Characteristically, there is early and almost constant involvement of one or both temporal lobes, although there are common additional areas of involvement. Appropriate early treatment following correct diagnosis by clinical findings, CSF study, EEG and several radiological studies including angiography, radionuclide studies, CT or MRI can reduce its mortality and severity of the sequelae. We report a case of HSE diagnosed by adjuvant study of 99m Tc-HMPAO regional cerebral blood flow SPECT, which showed a marked increase in bitemporal cerebral blood flow in a 24-year-old man.

  1. Brain perfusion ratios by 99mTc HMPAO SPECT utilizing a mean value of the visual cortex to the cerebellum ratio derived from normal subjects

    International Nuclear Information System (INIS)

    Sanchez Catasus, C.; Rodriguez, R.; Cisnero, M.; Palmero, R.; Diaz, O.; Aguila, A.

    2002-01-01

    Aim: Previous results shows that the cerebellum (CER) is the best reference to calculate relative indexes of perfusion (IP) by brain SPECT. However, it can not be used on patients with bilateral cerebellar hypoperfusion. In such cases visual cortex (VC) or an average of the whole brain activity is recommended (WB). VC and WB are less reliable than CER, making it difficult to compare SPECT scans that have been normalized with different values. Materials and Methods: To overcome this difficulty, we developed a method to calculate IP utilizing a reference value defined as (VC / ), where is the mean value of the VC/CER ratio derived from a normal database which was assumed to be constant. We called the value VC/ the 'Pseudocerebellum' (PCER). For clinical validation, we first tested statistically the VC/CER ratio on a group of 60 [ 99m Tc]-HMPAO SPECT scans of 20 normal subjects and 40 neurological patients with positive SPECT but without involvement of VC and CER. To demonstrate that IP PCER approx. IP CER , we calculated the mean value of the absolute differences CER - IP PCER vertical bar> on two groups of scans from subjects without involvement of VC and CER: 10 normal subjects (GI); and 40 patients (GII). Finally, using an indirect procedure the method was tested on a third group of SPECT scans of 30 patients with bilateral cerebellar hypoperfusion (G III). Results: The VC/CER ratio was approximately constant with gender and age at a 95% confidence level; CER - IP PCER vertical bar> was 1.22%±0.35 and 1.20%±0.42 for GI and GII, respectively. This is less than the within-subject replicability of the HMPAO SPECT studies; and thus demonstrated by an indirect approach that IP PCER is a valid procedure by which to evaluate relative perfusion on patients with bilateral cerebellar hypoperfusion and quantitatively comparable to using CER as reference region. Conclusion: The VC/CER ratio has very little inter-subject variability in individuals where these regions are not

  2. Tc99m-HMPAO Neuro--SPECT Assessment of Ischemic Penumbra in Acute Brain Infarct: Control of Intra-arterial Thrombolysis Treatment

    International Nuclear Information System (INIS)

    Mena, Francisco; Mena, Ismael; Ducci, Hector; Soto, Francisco; Pedraza, Luis; Contreras, Andrea; Miranda, Marcelo; Basaez, Esteban; Fruns, Manuel

    2004-01-01

    Acute brain infarct is a medical emergency potentially reversible if treated with thrombolysis, an approved therapy, if performed in the first 3 to 6 hours of evolution. Thrombolysis has many benefits, but it also has associated risks, mainly development of intracranial hemorrhage. The selection of which patient should receive this type of treatment had been an important research topic over the last decade. As a consequence neuroimaging of brain infarct has significantly improved during the last few years. A variety of diagnostic studies are now available in the evaluation of brain infarct and in particular of potentially reversible brain ischemia, including magnetic resonance imaging (MRI) diffusion-perfusion, perfusion computed tomography (CT) and functional neuroimaging techniques includes positron emission tomography (PET) and single-photon emission tomography (SPECT). The aim of this study is to present our experience with a group of patients that presented with acute brain ischemia and had a NeuroSPECT evaluation before and after intra-arterial thrombolysis and/or possible stent placement, in the treatment of acute brain infarct. Methods: 16 patients were treated acutely for a significant ischemic stroke with the following protocol. 1) Admission, and complete neurological evaluation. 2) Brain CT scan performed to rule out hemorrhage or established infarct. 3) IV injection of 1100MBq Tc 99m HMPAO (Ceretec tm ) 4) Conventional cerebral angiography and intra-arterial thrombolysis with tPA and /or angioplasty/stent if necessary. 5) NeuroSPECT assessment of ischemic penumbra (Pre-therapy results). 6) 14 of 16 patients received a NeuroSPECT (Post-therapy results) control at 24 hours. NeuroSPECT image acquisition was performed immediately following arterial thrombolysis with a dual Head Camera, Siemens ECAM, SHR collimators and conventional protocol. Image processing was performed using the Neurogam, Segami Corp. Software as previously reported in Alasbimn Journal 2

  3. Intrasubject comparison of regional cerebral blood flow between N-isopropyl-p-[123I]iodoamphetamine SPECT and 99mTc-hexamethylpropyleneamine oxime SPECT in patients with ischemic cerebrovascular disease

    International Nuclear Information System (INIS)

    Isaka, Yoshinari; Yoshikawa, Takuya; Ohe, Yohsuke; Nakayama, Hirofumi; Abe, Tohru; Ashida, Keiichi; Imaizumi, Masatoshi; Tanaka, Seiji

    1995-01-01

    Regional cerebral blood flow (CBF) was compared on CBF-SPECT brain images using two perfusion imaging agents, N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) and 99m Tc-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO), in the same patients with ischemic cerebrovascular disease. The subjects were 8 healthy volunteers (group A) and 16 patients with chronic cerebral infarction (group B). SPECT data were normalized to the count density of the tracer in the whole brain, and then converted to the absolute units of CBF by multiplying average 113 Xe-CBF in the whole brain. One-way analysis of variance (ANOVA), grouped by right and left hemispheres in group A and the affected and contralateral hemispheres in group B, was used to assess changes in regional CBF patterns in the two groups. CBF in all regions was significantly reduced on SPECT images, irrespective of the tracers, in group B. F value was higher on IMP images than HMPAO images for the frontal, temporal and occipital cortices, thalamus, and striatum); on the contrary, it was higher on HMPAO images than IMP images for the central lobule, parietal cortex, hippocampus, and centrum semiovale. Two-way ANOVA, grouped by the affected hemisphere in group B, tracer, and affected hemisphere x tracer, indicated that effects of tracer and affected hemisphere x tracer for regional CBF were not significant. For cortical infarction (n=8), regional CBF values in the infarct core were 14.8±4.1 ml/100 g/min on IMP images and 17.6±3.8 ml/100 g/min on HMPAO images; the corresponding figures for the contralateral region were 34.7±8.6 ml/100 g/min and 32.6±8.4 ml/100 g/min. Image contrast was better on IMP images than HMPAO images. In conclusion, an intrasubject comparison in ischemic cerebrovascular disease showed that the detectability of HMPAO CBF-SPECT for CBF abnormalities is roughly equivalent to that of IMP-CBF-SPECT. (N.K.)

  4. Validation and the limits of SPECT for patients suffering from cerebrovascular accidents. Evaluations based on simultaneous PET and SPECT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1989-02-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO{sub 2}) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO{sub 2} during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO{sub 2} on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO{sub 2} value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO{sub 2} areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.).

  5. 99mTc-HMPAO perfusion indices and brain-mapping in stroke patients

    International Nuclear Information System (INIS)

    Minchev, D.; Klisarova, A.

    1997-01-01

    It is the purpose of the study to establish correlations between 99mTc-HMPAO (hexamethylpropylenaminoxym) perfusion indices and changes in brain-mapping among patients with acute stroke. Forty-six patients with definitely proved stroke syndrome are investigated in the first 72 hours and 15 days after the onset of cerebrovascular accident using clinical, neuro-physiological and 99mTc-HMPAO SPECT methods. Regional and hemispheric perfusion asymmetry correlate with the brain-mapping cerebral disturbance (p < 0.001). In patients presenting focal hypoperfusion there is a significant correlation between perfusion indices and local EEG disturbance (r = 0.87). The dynamic study demonstrates a significant correlation between perfusion indices and electrical cerebral disturbance in the first 72 hours after the onset of the cerebrovascular accident. Fifteen days later no such correlation is documented. The obtained results demonstrate the essential practical bearing of 99mTc-HMPAO SPECT indices on the objective assessment of perfusion hemispheric and regional asymmetry in stroke patients, and the possibility of being used for indirect estimation of the regional cerebral blood flow in acute stroke patients against the background of visual and quantitative EEG changes (author)

  6. Cerebral blood flow imaging by I-123 IMP and Tc-99m HM-PAO

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Koichi; Yoshikawa, Kyosan; Minoshima, Satoshi; Imaseki, Keiko; Arimizu, Noboru; Yamaura, Akira; Uematsu, Sadao

    1988-02-01

    SPECT studies with either N-isopropyl-p-(I-123)iodo- amphetamine (I-123 IMP) or Tc-99m hexamethyl propylene amine oxime (Tc-99m HM-PAO) were cuncurrently performed in 12 patients with brain disorders, comprising cerebral infarction (7), cerebral aneurysm (one), intracranial hemorrhage (3), and subdural hematoma (one). Whereas I-123 IMP was taken up gradually into the brain, the uptake of Tc-99m-HM-PAO in the brain reached the peak immediately after the iv injection, with 90% or more remaining constant by 15 min postinjection. On early SPECT images, a high uptake of I-123 IMP was observed in the lung, and the uptake of Tc-99m HM-PAO was observed as well in the soft tissue of cervical region. In all patients except for one, decreased rCBF was observed in the lesions on both I-123 and Tc-99m SPECT scans. Both of the radiopharmaceuticals were analogous in that decreased blood flow corresponded to cerebral lesions. (Namekawa, K).

  7. Cerebral perfusion (HMPAO-SPECT) in patients with depression with cognitive impairment versus those with mild cognitive impairment and dementia of Alzheimer's type: a semiquantitative and automated evaluation

    International Nuclear Information System (INIS)

    Staffen, W.; Bergmann, J.; Schoenauer, U.; Kronbichler, M.; Golaszewski, S.; Ladurner, G.; Zauner, H.

    2009-01-01

    Comparative evaluation of regional brain perfusion measured by HMPAO-SPECT of patients with mild cognitive impairment (MCI), dementia of Alzheimer's type (DAT) and depression with cognitive impairment (DCI). A total of 736 patients were investigated because of suspected cognitive dysfunction. After exclusion of patients with other forms of dementia than DAT or relevant accompanying disorders, SPECT data from 149 MCI, 131 DAT and 127 DCI patients, and 123 controls without any cognitive impairment, were analysed. Relative cerebral blood flow of 34 anatomical regions was assessed with automated analysis software (BRASS). Calculation of global forebrain perfusion discriminated demented from nondemented patients. Compared to controls DCI patients showed hypoperfusion of the thalamus, lentiform nucleus and medial temporal cortex. MCI patients differed significantly from controls concerning perfusion in both hemispheric temporal and parietal areas, and in the (right hemispheric) posterior part of the cingulate gyrus. MCI and DCI patients differed in the parietal, temporal superior and right hemispheric cingulate gyrus posterior cortices. Global forebrain and regional perfusion was more extensively reduced in DAT patients and discriminated them from controls, and MCI and DCI patients. Frontal perfusion disturbance was only present in DAT patients. Automated analysis of HMPAO-SPECT data from MCI patients showed significant perfusion deficits in regions also involved in DAT patients, but ROC analysis demonstrated only moderate sensitivity and specificity for differentiating DAT patients from controls and DCI patients. Frontal hypoperfusion seems to correspond with conversion from MCI to DAT. Finally, the results in DCI patients again raise the question of depression as an early symptom of neurodegeneration. (orig.)

  8. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  9. Change of cerebral blood flow distribution and vascular reserver according to age in Koreans measured by Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Song, Ho Cheon; Bom, Hee Seung; Sohn, Hye Kyung; Jeong, Hwan Jeong; Min, Jung Jun; Kim, Ji Yeol; Lee Jae Tae; Moon, Dae Hyuk; Lee, Hee Kyung

    1999-01-01

    The aim of this study was to evaluate the normal values of regional cerebral blood flow (rCBF) and cerebrovascular reserve (CVR) in normal children to aged volunteers using Tc-99m HMPAO. Thirty four right-handed normal volunteers (20 males, 14 females, mean age 40.3±24.9 years, range 4 to 82 years) were underwent rest/acetazolamide (ACZ) brain SPECT using Tc-99m HMPAO and the sequential injection and subtraction method. rCBF was estimated on the basis of a semiquantitative approach by means of right/left ratio, region/cerebellum and region to whole brain ratios in frontal, parietal, temporal, and occipital lobes, basal ganglia, thalami, and cerebellum. CVR was measured by means of % perfusion increase calculated as % mean count change compared to rest rCBF in each regions. Mean values of right to left ratios range from 1.004 to 1.018. rCBF was highest in cerebellum and lowest in basal ganglia and thalami. Frontal and temporal rCBF decreased while occipital and thalamic rCBF increased according to age. No sexual difference of rCBF was noted. Mean CVR was 29.9±12.9%. Mean CVR significantly increased to late teens, and declined thereafter. After 6th decade, CVR in both frontal lobes, left parietal lobe and right basal ganglia decreased significantly with advancing age. There was no sexual difference of CVR. Quantitative assessment of CVR was possible by ACZ Tc-99m MHPAO brain SPECT. It revealed that rCBF and CVR changed according to age in normal Korean volunteers. There was no sexual difference

  10. The value of rCBF brain SPECT in assessing visual function of patients with honeymoons hemianopia

    International Nuclear Information System (INIS)

    Xie Ruiman; Yao Jingli; Qing Zheng

    1995-01-01

    Comparison of 99m Tc-HMPAO brain SPECT imaging of 8 cases with honeymoons hemianopia (HH) was taken before and after a course of oriented dynamic color photic stimulation (ODCPS). It was suggested that ODCPS in patients with HH was an effective method for increasing visual field and improving visual function. Cerebral metabolic patterns reflected the mechanism of ODCPS effecting the patients with HH. The retinal midbrain-occipital visual path-way may play an important role in mediating the increase of visual field and restoration of visual function. It was also concluded that brain SPECT imaging was an useful method for the studying of brain function

  11. Cerebral perfusion (HMPAO-SPECT) in patients with depression with cognitive impairment versus those with mild cognitive impairment and dementia of Alzheimer's type: a semiquantitative and automated evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Staffen, W.; Bergmann, J.; Schoenauer, U.; Kronbichler, M.; Golaszewski, S.; Ladurner, G. [Paracelsus Medical University, Christian-Doppler-Clinic, Department of Neurology, and Center of Cognitive Research Salzburg, Salzburg (Austria); Zauner, H. [Rehabilitation Center of the Pensionsversicherungsanstalt, Grossgmain (Austria)

    2009-05-15

    Comparative evaluation of regional brain perfusion measured by HMPAO-SPECT of patients with mild cognitive impairment (MCI), dementia of Alzheimer's type (DAT) and depression with cognitive impairment (DCI). A total of 736 patients were investigated because of suspected cognitive dysfunction. After exclusion of patients with other forms of dementia than DAT or relevant accompanying disorders, SPECT data from 149 MCI, 131 DAT and 127 DCI patients, and 123 controls without any cognitive impairment, were analysed. Relative cerebral blood flow of 34 anatomical regions was assessed with automated analysis software (BRASS). Calculation of global forebrain perfusion discriminated demented from nondemented patients. Compared to controls DCI patients showed hypoperfusion of the thalamus, lentiform nucleus and medial temporal cortex. MCI patients differed significantly from controls concerning perfusion in both hemispheric temporal and parietal areas, and in the (right hemispheric) posterior part of the cingulate gyrus. MCI and DCI patients differed in the parietal, temporal superior and right hemispheric cingulate gyrus posterior cortices. Global forebrain and regional perfusion was more extensively reduced in DAT patients and discriminated them from controls, and MCI and DCI patients. Frontal perfusion disturbance was only present in DAT patients. Automated analysis of HMPAO-SPECT data from MCI patients showed significant perfusion deficits in regions also involved in DAT patients, but ROC analysis demonstrated only moderate sensitivity and specificity for differentiating DAT patients from controls and DCI patients. Frontal hypoperfusion seems to correspond with conversion from MCI to DAT. Finally, the results in DCI patients again raise the question of depression as an early symptom of neurodegeneration. (orig.)

  12. Reduced brain perfusion in basal forebrain associated with cognitive decline in Alzheimer's diseases: a Tc-99m HMPAO SPECT study

    International Nuclear Information System (INIS)

    Lee, M.C.; Kang, H.; Kang, E.; Lee, J.S.; Lee, D.S.; Lee, D.W.; Cho, M.J.

    2002-01-01

    Aim: Reduction of regional cerebral blood flow (rCBF) in various cerebral regions and decline of cognitive function have been reported in Alzheimer's disease (AD) patients. The aim of this study was to identify the brain areas showing correlation between longitudinal changes of rCBFs and decline of general mental function, measured by Mini-Mental State Examination (MMSE) in probable Alzheimer's disease patients. Materials and Methods: Nine probable AD patients according to NINCDS-ADRDA criteria and DSM-IV were studied with Tc-99m HMPAO SPECT at an initial point and at the follow-up after a period of average 1.8 year. MMSE score was obtained in both occasions (average MMSE 16.4 at initial study; average MMSE = 8.1 at follow-up). Single SPECT was performed in 30 age-matched normal controls. Each SPECT image was normalized to the cerebellar activity. Using statistical parametric mapping (SPM99), correlation was analyzed between individual changes in rCBF of two SPECT scans and the MMSE scores at the time of each study in AD patients. In addition, the SPECT images of the initial study and the follow-up study were compared with SPECT images of the age-matched normal group respectively. Results: Significant correlation between longitudinal changes of rCBFs and MMSE scores was found in left basal forebrain region including substantia innominata (x, y, z = -24, 16, -23; P < .05, corrected). Within a short follow-up period of 1.8 years, cerebral hypoperfusion extended to various cortical regions from bilateral temporo-parietal to bilateral frontal regions and cingulate cortex, compared to normal controls. Conclusion: The decline of cognitive function in individual AD patients was correlated with rCBF reduction in left basal forebrain. This finding supports the cholinergic hypothesis of AD since hypoperfusion in basal forebrain region might indicate deterioration of cholinergic neurons in nucleus basalis of Meynert or substantia innominata

  13. Dose response from pharmacological interventions for CBF changes in a baboon model using 99Tcm-HMPAO and SPECT

    International Nuclear Information System (INIS)

    Dormehl, I.C.; Hugo, N.; Oliver, D.W.

    1993-01-01

    This study assesses the sensitivity of the baboon model under anaesthesia to determine by single photon emission computed tomography (SPECT) and 99 Tc m -hexamethylpropyleneamine oxime (HMPAO) dose responses from drugs (acetazolamide) with known regional cerebral blood flow (rCBF) effects on humans. Three dosages of acetazolamide were chosen: 250, 500 and 750 mg. The effects of these were studied by conventional SPECT 5 min after intravenous (i.v.) administration and compared to previous studies of rCBF with the baboons under anaesthesia only. An additional study concerned the effect of 500 mg acetazolamide at 15 min after administration. Haemodynamic parameters and blood gases were also monitored. No statistically significant regional effects were noted. The largest increase in CBF (39%) was observed from 500 mg acetazolamide after 5 min. This was statistically significantly different from control values only at a 10% level of confidence; then following a 27% increase above control values after 750 mg (5 min). At 15 min 500 mg yielded values lower by 10% than the high dose. No effects were observed from 250 mg acetazolamide; only pO 2 showed changes which largely confirm the CBF findings. The model did not give significant results at a 5% level of confidence but large fluctuations were observed, also in the haemodynamic and blood gas values. At a 10% level a significant dose response was confirmed for acetazolamide. (author)

  14. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  15. Technetium-99m HMPAO brain SPECT in children with attention deficit hyperactivity disorder

    International Nuclear Information System (INIS)

    Kaya, G.C.; Pekcanlar, A.; Bekis, R.; Ada, E.; Miral, S.; Emiroglu, N.; Durak, H.

    2002-01-01

    Attention deficit hyperactivity disorder (ADHD) is a developmental, neurobehavioral syndrome with an onset in childhood. The aim of this study was to investigate the existence of regional perfusion changes in ADHD by means of Tc-99m HMPAO brain SPECT. Thirteen children with a diagnosis of ADHD and 7 healthy, age-matched controls were included in this study. Hypoperfusion was observed on the right temporal cortex in 9, and on the left temporal cortex in 3 children. The distribution of the lesions showed right lateral temporal cortex involvement in 3, right medial temporal cortex in 9 and left medial temporal cortex in 8 children. Asymmetric perfusion was seen on the caudate nucleus in 4, on the thalamus in 3 and on the frontal cortex in 6 children. There was a significant difference between children with ADHD and controls in right medial temporal cortex: cerebellum and right lateral temporal cortex: cerebellum ratios. Hypoperfusion in the right medial temporal cortex was significantly and inversely correlated with Du Paul teachers' questionnaire rating scale (r=-0.71, p=0.006). It has been postulated that difficulty in self regulating response to stimuli in ADHD is mediated by underfunctioning of the orbital frontal cortex and subsequent connection to the limbic system. Decreased temporal cortex perfusion may dysfunction of the limbic system or the orbito-frontal-limbic axis. (author)

  16. Technetium-99m HMPAO brain SPECT in children with attention deficit hyperactivity disorder

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, G.C.; Pekcanlar, A.; Bekis, R.; Ada, E.; Miral, S.; Emiroglu, N.; Durak, H. [Dokuz Eylul Univ., Izmir (Turkey). School of Medicine

    2002-12-01

    Attention deficit hyperactivity disorder (ADHD) is a developmental, neurobehavioral syndrome with an onset in childhood. The aim of this study was to investigate the existence of regional perfusion changes in ADHD by means of Tc-99m HMPAO brain SPECT. Thirteen children with a diagnosis of ADHD and 7 healthy, age-matched controls were included in this study. Hypoperfusion was observed on the right temporal cortex in 9, and on the left temporal cortex in 3 children. The distribution of the lesions showed right lateral temporal cortex involvement in 3, right medial temporal cortex in 9 and left medial temporal cortex in 8 children. Asymmetric perfusion was seen on the caudate nucleus in 4, on the thalamus in 3 and on the frontal cortex in 6 children. There was a significant difference between children with ADHD and controls in right medial temporal cortex: cerebellum and right lateral temporal cortex: cerebellum ratios. Hypoperfusion in the right medial temporal cortex was significantly and inversely correlated with Du Paul teachers' questionnaire rating scale (r=-0.71, p=0.006). It has been postulated that difficulty in self regulating response to stimuli in ADHD is mediated by underfunctioning of the orbital frontal cortex and subsequent connection to the limbic system. Decreased temporal cortex perfusion may dysfunction of the limbic system or the orbito-frontal-limbic axis. (author)

  17. Technetium-99m HMPAO brain SPECT in children with attention deficit hyperactivity disorder

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, G C; Pekcanlar, A; Bekis, R; Ada, E; Miral, S; Emiroglu, N; Durak, H [Dokuz Eylul Univ., Izmir (Turkey). School of Medicine

    2002-12-01

    Attention deficit hyperactivity disorder (ADHD) is a developmental, neurobehavioral syndrome with an onset in childhood. The aim of this study was to investigate the existence of regional perfusion changes in ADHD by means of Tc-99m HMPAO brain SPECT. Thirteen children with a diagnosis of ADHD and 7 healthy, age-matched controls were included in this study. Hypoperfusion was observed on the right temporal cortex in 9, and on the left temporal cortex in 3 children. The distribution of the lesions showed right lateral temporal cortex involvement in 3, right medial temporal cortex in 9 and left medial temporal cortex in 8 children. Asymmetric perfusion was seen on the caudate nucleus in 4, on the thalamus in 3 and on the frontal cortex in 6 children. There was a significant difference between children with ADHD and controls in right medial temporal cortex: cerebellum and right lateral temporal cortex: cerebellum ratios. Hypoperfusion in the right medial temporal cortex was significantly and inversely correlated with Du Paul teachers' questionnaire rating scale (r=-0.71, p=0.006). It has been postulated that difficulty in self regulating response to stimuli in ADHD is mediated by underfunctioning of the orbital frontal cortex and subsequent connection to the limbic system. Decreased temporal cortex perfusion may dysfunction of the limbic system or the orbito-frontal-limbic axis. (author)

  18. The validation and the limits of SPECT for patients suffering from cerebrovascular accidents

    International Nuclear Information System (INIS)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi

    1989-01-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO 2 ) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO 2 during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO 2 on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO 2 value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO 2 areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.)

  19. Rigiscan®-Monitoring der Erektion unter audiovisueller sexueller Stimulation ohne/mit Viagra™ bei Patienten mit erektiler Dysfunktion

    Directory of Open Access Journals (Sweden)

    Perabo FGE

    2000-01-01

    Full Text Available Die orale Medikation mit Sildenafil (Viagra™ hat sich zur Therapie der erektilen Dysfunktion etabliert und relativiert die Differentialdiagnose zwischen psychogener und organischer Dysfunktion mit den entsprechenden therapeutischen Konsequenzen. Diesem Problem widmet sich diese Studie zur Prüfung der erektilen Antwort unter RigiScan®-Monitoring ohne/mit 50 mg Viagra™. 64 Patienten (mittleres Alter 48 Jahre mit einer erektilen Dysfunktion arteriogener (n = 10, venöser (n = 7, gemischt neurogen/vaskulärer (n = 15 und psychogener (n = 32 Genese von mehr als 6 Monaten Dauer wurden in die Studie aufgenommen. Alle Patienten wurden eingehend diagnostisch abgeklärt, inklusive Hormonlabor, dynamischer Pharmako-Duplexsonographie und, falls indiziert, mit einer Cavernosometrie/ -graphie. Zur Testung der penilen Rigidität und zur Objektivierung der Erektion wurde das "real-time" RigiScan® verwendet. In zwei konsekutiven Messungen wurden sowohl die direkte erektile Antwort auf visuelle Stimulation als auch die nächtlichen Erektionen abgeleitet und die Meßergebnisse mit den Begleiterkrankungen, "lifestyle"-Faktoren und dem Ergebnis der Pharmako-Duplexsonographie korreliert. Es fand sich keine Korrelation zwischen der Ätiologie der erektilen Dysfunktion in bezug auf organische oder psychogene Genese und dem Alter der Patienten, der Dauer der Erektionsstörung, dem Nikotinabusus, den Blutfetten, den Testosteronwerten, dem klinischen Ergebnis der Pharmakotestung (Erektionsgrad und dem duplexsonographisch gemessenen Fluß der penilen Arterien. Hingegen zeigte sich eine positive Korrelation zwischen Genese der erektilen Dysfunktion (organisch bzw. psychogen und dem RigiScan®-Meßergebnis (r = 0,29. Patienten mit psychogen bedingter Erektionsstörung profitierten am meisten von Viagra™, während Patienten mit vaskulärer Genese oder gemischt neurogener/vaskulärer Genese deutlich schlechter auf Viagra™ ansprachen. Es bestand keine Korrelation

  20. Brain SPECT imaging in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Krausz, Y.; Yaffe, S.; Atlan, H.; Cohen, D.; Konstantini, S.; Meiner, Z.

    1991-01-01

    Temporal lobe epilepsy is diagnosed by clinical symptoms and signs and by localization of an epileptogenic focus. A brain SPECT study of two patients with temporal lobe epilepsy, using 99m Tc-HMPAO, was used to demonstrate a perfusion abnormality in the temporal lobe, while brain CT and MRI were non-contributory. The electroencephalogram, though abnormal, did not localize the diseased area. The potential role of the SPECT study in diagnosis and localization of temporal lobe epilepsy is discussed. (orig.)

  1. Comparison of D2 receptor binding (123I-IBZM) and rCBF (99mTc-HMPAO) in extrapyramidal disorders

    International Nuclear Information System (INIS)

    Saur, H.B.; Bartenstein, P.; Schober, O.; Oberwittler, C.; Lerch, H.; Masur, H.

    1994-01-01

    The aim of this SPECT study was to determine whether there is a correlation between rCBF ( 99m Tc-HMPAO) and D2 receptor binding ( 123 I-IBZM) in disorders of the extrapyramidal system and in which situation the 99 MTc-HMPAO scan could predict the outcome of the 123 I-IBZM study. 13 patients with Parkinson's syndrome and 13 patients with hyperkinetic extrapyramidal disorders were studied. In all patients the two SPECT studies were performed within 2-7 days. ROIs were placed over the basal ganglia (BG), the frontal cortex (FC) and the cerebellum (CE). The ratios BG/FC and BG/CE were calculated. In both groups the scatter was lower when the frontal cortex was used as reference region. Among the patients with hyperkinetic extrapyramidal hyperkinetic extrapyramidal disorders the two patients with Huntington's chorea had lower rCBF and D2 receptor binding compared to other hyperkinetic extrapyramidal disorders. There was no correlation between D2 receptor binding and rCBF in the basal ganglia. The 99 MTc-HMPAO studies did not provide clinically useful information, except in Huntington's chorea. (orig.) [de

  2. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  3. 99mTc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    International Nuclear Information System (INIS)

    Yang, Hyung In; Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon

    1994-01-01

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  4. Follow-up findings in regional cerebral blood flow (r-CBF)-SPECT in a case of idiopathic childhood hemidystonia. Functional neuroimaging and pathophysiological implications

    International Nuclear Information System (INIS)

    Fiedler, A.; Aderbauer, J.; Segerer, H.; Marienhagen, J.; Bock, E.; Eilles, C.

    1999-01-01

    A 9 1/2-year-old girl suffered from intermitting tremor and jitteriness of her left hand and oral muscles every 4 to 6 weeks with long lasting episodes. Clinically myoclonias and dystonic positioning of the left arm, hand and facial muscles were seen. No evidence of trauma, infection or inborn errors of metabolism was found. Successful therapy with carbamazepine was initiated while L-DOPA failed. An ictal 99m-Tc-HMPAO-SPECT showed severe asymmetry with focal hyperperfusion of the contralateral right thalamus and basal ganglia as well as of the bifrontal cortex, whereas no anatomical lesions were found by MRI. In contrast, an interictally performed 99m-Tc-HMPAO SPECT showed hypoperfusion or the right thalamus and normalisation of the frontal perfusion under medical treatment. These 99m-Tc-HMPAO-SPECT findings may provide new insights into the localisation and pathophysiological pathways of idiopathic childhood dystonia. (orig.) [de

  5. The role of brain SPECT in children with epilepsy

    International Nuclear Information System (INIS)

    Liu Xingdang; Liu Yongchang; Lin Xiangtong

    1996-01-01

    The rCBF brain SPECT with 99m Tc-HMPAO was performed in 15 children with interictal epilepsy, and some cases were compared with EEG, X-ray CT and MRI. The results showed that the positive rate of SPECT was the highest (93.33%,), then the EEG (92.31%), and the CT and MRI were the lowest (66.67% and 75%). This study indicated that brain SPECT was an effective method for diagnosis and foci localization in epileptic children, and also was useful to the study of prognosis and relationship between changes of rCBF and progress in clinical pictures

  6. Regional cerebral blood flow studies with single photon emission computed tomography (SPECT); Clinical experiences, possibilities. Regionalis agyi veratfolyas vizsgalata egyfotonos emissios computer tomographiaval (SPECT); Klinikai tapasztalatok, lehetoesegek

    Energy Technology Data Exchange (ETDEWEB)

    Pavics, Laszlo; Csernay, Laszlo; Doczi, Tamas; Lang, Jenoe; Blaho, Gabor; Janka, Zoltan; Bodosi, Mihaly [Szegedi Orvostudomanyi Egyetem, Szeged (Hungary)

    1990-01-07

    Clinical experiences based on regional cerebral blood flow investigations with {sup 99m}Tc hexamethylpropyleneamin-oxime (HMPAO) SPECT in 164 patients are reported. The pharmacokinetics of the {sup 99m}Tc HMPAO are summarized, and the important indications of the investigations are interpreted in case reports (stroke, surgical solution of intracavernous aneurysm, Alzheimer and multiinfarct types of dementia). The literature data suggest that the diagnostic possibilities with this method are advantageous, even in other diseases. (author) 36 refs.; 7 figs.

  7. Quantitative Analysis of Regional Cerebral Blood Flow using 99mTc-HMPAO SPECT in Parkinson's Disease

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin; Lee, Myung Hae

    1992-01-01

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using 99m Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 ± 0.033 and 0.108 ± 0.062, respectively and PIA were -0.4 ± 0.7% and -0.7 ± 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  8. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    International Nuclear Information System (INIS)

    Sundstroem, Torbjoern; Riklund, Katrine Aa.; Elgh, Eva; Naesman, Birgitta; Larsson, Anne; Nyberg, Lars

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2±4.8 years) with mild AD and 18 healthy elderly (69.4±3.9 years) were included in the study. The subjects were injected with 99m Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF 99m Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  9. Tc-99m HMPAO brain uptake patterns in patients with dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Costa, D.C.; Burns, A.; Philpot, M.; Levy, R.; Ell, P.J.

    1988-01-01

    Conventional gamma camera SPECT with Tc-99m HMPAO (10 MBq/kg patient weight) was carried out in 21 patients with dementia of Alzheimer type (DAT), fulfilling the criteria established by the National Institute of Neurological and Communicative Disorders and Stroke and the ADRDA criteria (nine with amnesia as the main symptom [group 1], 12 with amnesia, aphasia, and/or apraxia and agnosia [group 2], and eight age-matched control subjects. Perfusion was quantitatively studied by means of cerebrum-cerebellum activity ratios. In group 1, perfusion deficits in the mesial cortex of the temporal lobes (right, 0.70; left, 0.68) were found, and ratios were significantly lower than in the control group (right, 0.77; left, 0.76 [P < .05]). Group 2 showed low ratios throughout both temporal lobes (mesial and lateral cortex), bilaterally in the posterior parietal cortex (right, 0.69; left, 0.66 [control: right, 0.80; left, 0.81] [P < .001]), and left frontal cortex (0.75 [control, 0.79] [P < .05]). In conclusion, SPECT with Tc-99m HMPAO identifies perfusion deficits in patients with DAT, and these correlate well with the clinical findings and are significantly different from those in the control group

  10. {sup 99m}Tc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hyung In [Kyunghee University Hospital, Seoul (Korea, Republic of); Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon [Seoul National University Hospital, Seoul (Korea, Republic of)

    1994-03-15

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  11. A case of Cotard syndrome: (123)I-IBZM SPECT imaging of striatal D(2) receptor binding.

    Science.gov (United States)

    De Risio, Sergio; De Rossi, Giuseppe; Sarchiapone, Marco; Camardese, Giovanni; Carli, Vladimir; Cuomo, Chiara; Satta, Maria Antonietta; Di Giuda, Daniela

    2004-01-15

    A case of 'dèlire de nègation' that suddenly appeared in a 43-year-old male is presented. No alteration in regional cerebral blood, as measured by (99m)Tc-HMPAO-SPECT, was found, but (123)I-IBZM-SPECT analysis showed reduced striatal D(2) receptor binding that further decreased after treatment.

  12. Evaluating acute effects of Electro Convulsive Therapy (ECT) on brain perfusion with Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Ozguven, M.; Ozturk, E.; Gunalp, B.; Ozgen, F.; Bayhan, H.

    1992-01-01

    Regional cerebral blood flow (rCBF) was measured by Tc-99m HMPAO brain perfusion SPECT in 10 schizophrenes (8 male, 2 female) undergoing electro convulsive therapy (ECT) and the results were compared to those of baseline studies performed 3 days prior to the ECT application to evaluate its acute effect on brain perfusion. ECT caused a redistribution in the tracers uptake. There was a global increase in the rCBF and the uptake became more pronounced in the basal ganglia (left: 44.4+-1.9%, right: 43.1+-19%) and to a degree in the parietal (left: 26.5+-4.1%, right: 25+-3.4%) and temporal (left: 22.9+-4.3%, right: 22.3+-3.6%) cortices. When evaluating the effects of ECT on rCBF, factors like the used perfusion agent, the injection and rCBF measurement times, clinical status of the patient, duration of the illness, used therapeutic agents and variations in the ECT application should be taken into consideration because the obtained data may reflect either the ictal or post-ictal changes on rCBF and is specific to the group of patients undergoing the study

  13. Utility of Brain SPECT 99mTc-HMPAO scintigraphy for the evaluation of regional cerebral blood flow changes in patients suffering from dissociative amnesia DA and dissociative motor disorders DMD (previously termed as hysteria)

    International Nuclear Information System (INIS)

    Ali, F.

    2007-01-01

    Full text: The aim of the study was to assess the utility of Brain SPECT 99 mTc-HMPAO scintigraphy for the evaluation of regional cerebral blood flow changes in patients suffering from dissociative amnesia (DA) and dissociative motor disorders (DMD) (previously termed as Hysteria). Materials and Methods: 20 patients were included in the study with a mean age of 26 years, 08 of them suffering from DA and 12 from DMDs. A consultant psychiatrist on the basis of ICD-10 criteria made the diagnosis. Patients were divided into two categories according to the duration of their illness. Category A; included 10 patients having less than six months duration of illness. Category B; included 10 patients having duration of illness more than six months. Ten normal controls having no signs and symptoms of any psychiatric disorder were also included in the study. Brain SPECT study was carried out using 99 mTc-HMPAO. Semiquantitative analysis was done by calculating cortical and cerebellar ratios in normals and comparing the same in the patients. Results: By comparing regional cerebral blood flow ratios of both the categories with normal group, patients suffering from DA showed hypoperfusion in bilateral temporal lobes, in both frontal association areas and both orbito frontal regions and patients suffering for more than 06 months showed a slightly more exaggerated pattern of hypoperfusion in the same cortical areas. On the other hand in DMD only the patients suffering for more than 06 months showed altered cerebral blood perfusion like hypoperfusion in both of the frontal motor areas, hypoperfusion in both temporal lobes and marked hyperperfusion in both orbito frontal areas. Conclusion: Patients of DA show abnormal cerebral perfusion pattern whether in acute or chronic stage while only chronic DMD states precipitate altered cerebral perfusion patterns and these can be visualized on a Brain SPECT study. (author)

  14. Cerebral perfusion study using 99mTc-HMPAO-ECT: Particular aspects regarding uptake and evaluation

    International Nuclear Information System (INIS)

    Spitz, J.; Clemenz, N.

    1988-01-01

    From the performance of about 250 99m Tc-HMPAO-SPECT studies for clarification of cerebro-vascular diseases, five essential problem groups have emerged: 1. Positioning of the patient's head and hence resulting rotation radius of the camera head. 2. Choice of the slice level for documentation and demonstration of the ECT study. 3. Standardization and colour codation of the single slice images. 4. Localization and identification of single slices in different slice levels. 5. Quantification of the distribution pattern. Whether nuclear medical cerebral perfusion study for diagnosis of cerebro-vascular diseases using 99m Tc-HMPAO may be an equivalent to DSA und TCT in future, should at least partially depend upon an adequate answer to the presented problems. (orig.) [de

  15. Quantitative Analysis of Regional Cerebral Blood Flow using {sup 99m}Tc-HMPAO SPECT in Parkinson's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin [Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Myung Hae [Asan Medical Center, Seoul (Korea, Republic of)

    1992-07-15

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using {sup 99m}Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 +- 0.033 and 0.108 +- 0.062, respectively and PIA were -0.4 +- 0.7% and -0.7 +- 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  16. Scintigraphic assessment of cerebral blood flow changes in chrongic tobacco users using Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Saeed, S.; Raza, M.; Sohaib, M.

    2004-01-01

    HMPAO SPECT is a useful and readily available method for estimation of rCBE This study aimed at defining a correlation between chronic tobacco use and changes in cerebral blood flow, through visual and semi-quantitative scintigraphic assessment, rCBF in 48 chronic tobacco users and 11 quitters was evaluated, utilising a normal database created by HMPAO brain scans of 20 non-smokers. Subjects were classified into chronic tobacco users and non-tobacco users through the smoking index (SI). SI value of 100 was taken as the cut-off value. Tobacco users who had discontinued tobacco use for three months or more were classified as 'Quitters'. ROIs were declared hypo- or hyper-perfused if their percentage perfusion values relative to the average perfusion per pixel of the whole slice did not fall within + 2 SD of the mean regional perfusion in the corresponding ROI, in the normal control group.rCBF in chronic tobacco users was found to be far less than the non-tobacco users (P < 0.001). The quitters showed significantly better cerebral perfusion compared to the chronic tobacco users (P < 0.025) but their rCBF was still significantly decreased relative to the non-tobacco users (P < 0.005). In chronic tobacco users, the rCBF was decreased in parietal (P < 0.05) and occipital (P < 0.005) regions of the cortex, and increased in the temporal cortex (P < 0.001). The frontal cortex showed both hyperperfusion (P < 0.001) and hypoperfusion (P < 0.025), perhaps due to varying perfusion patterns in different areas / sub-regions of the frontal cortex. The cerebellar blood flow in chronic tobacco users was much decreased compared to the normal controls (P < 0.001).Generally, a satisfactory correlation between the results obtained visually and semi-quantitatively was found. Semi-quantitative approach, however, appeared better specially when regional radiotracer uptake (actual acquired average regional counts) were used as an adjunct to support the findings. (authors)

  17. Scintigraphic evaluation of brain death with 99mTc-d,l-hexamethyl-propyleneamine oxime (HMPAO)

    International Nuclear Information System (INIS)

    Takehara, Yasuo; Isoda, Haruo; Sakai, Tsuneo; Tanaka, Tokutaro; Sato, Haruhiko; Yamamoto, Takamichi; Takahashi, Motoichiro; Kaneko, Masao.

    1989-01-01

    Lately, the criteria of brain death is being discussed. Cerebral scintigram, especially scintigraphic evaluation of brain death by dynamic study, has been previously reported. Cerebral imaging using radiolabeled amines such as 123 I-IMP N-isopropyl-p-iodoamphetamin (IMP) or 99m Tc d, l-hexamethyl-propyleneamine oxime (HMPAO) offers a significant information of brain death by the finding of 'non visualized brain'. However, the dynamic scintigram acquired during the bolus injection of 99m Tc-HMPAO provides an additional information of brain death by classical 'hot nose sign'. 99m Tc-HMPAO is able to be administered relatively in a large amount of dose. This cerebral perfusion tracer is lipophilic and remains in the central nervous system, which characterize its role as a reliable indicator of cerebral blood flow. As a result, this compound became suitable for the non-invasive study of brain circulation when the diagnosis of brain death is uncertain. We report a case of brain death in which diagnosis was made by the classical 'hot nose sign' in dynamic scintigraphy performed when 99 mTc-HMPAO was injected as well as the SPECT which showed a lack of cerebral visualization at the equilibrium state. As far as we are informed, this additional procedure used in the diagnosis of brain death has not reported before. The importance of performing a dynamic scintigram at the administration of 99m Tc-HMPAO is also discussed in this report. (author)

  18. A clustering model proposal for activity optimization vs. image quality. Application in HMPAO-99mTc brain SPECT

    International Nuclear Information System (INIS)

    Perez, M.; Diaz, O.; Estevez, E.; Roque, R.; Hernandez, C.

    2008-01-01

    A method based on clustering analysis and image quality discriminant functions is tested over HMPAO- 99m Tc -SPECT images to optimize image quality vs. administered activity to patient. Signal-to-Noise ratios and Signal-to-Background ratios in each transaxial slice were measured over the images and used as image quality objective indexes. They were employed to develop image quality classification using a model of three clusters (k-mean Cluster Technique). The mathematical classification was compared with the subjective image quality evaluation, following expert observer criterion. Linear image quality discrimination was developed using the results of the cluster classification and taking as independent variables: the characteristics of the patients (sex, age and weight) and the radiopharmaceutical (labelling yield and administered activity). The dependent variables in the discriminant functions were the cluster centroids. The objective of this procedure was assigning a statistical weight to each image quality determinant variable for the optimization purpose. The method was applied in 30 brain SPECT images, acquired under different activities (400 MBq, 600 MBq, 800 MBq and 1000 MBq as reference), with a Sopha gamma camera, mean-resolution - general purpose - parallel-hole collimator, acquisition matrix 128 x 128 pixels and reconstruction following Filter - Back - Projection Algorithm. We looked for the minimum activity that guaranty most of the cases classified into the cluster with the best image quality (optimization criterion). The value of 800 MBq was the optimum obtained after application of the above methodology for the technology used. The labelling yield and the weight of the patients were the main parameters which determined image quality in clusters, as well as the processing digital filter used. The reduction in the effective dose, as a consequence of this procedure implementation, was also analysed. (author)

  19. Comparison of brain perfusion SPECT and MRI findings in children with neuronal ceroid-lipofuscinosis and in their families

    International Nuclear Information System (INIS)

    Sayit, E.; Yorulmaz, I; Gumuser, F.G.; Dirik, E.; Bekis, R.; Kaya, G.; Durak, H.

    2002-01-01

    Neuronal ceroid-lipofuscinoses (NCL) are among the progressive encephalopathies of childhood that are inherited in an autosomal recessive manner. In this study we specifically aimed to investigate any white-matter changes in the carriers (parents) and the healthy siblings of individuals with neuronal ceroid lipofuscinosis disease and whether we may be able to predict the occurrence of any neurological symptoms in healthy children in the future thus enabling early management. Since the NCLs are genetically determined diseases, we investigated fifteen individuals in three families that had diseased children of the juvenile type, with brain perfusion SPECT and MRI. Brain perfusion SPECT was performed after administering 222-555 MBq (6-15 mCi) Tc-99m hexamethyl-propylene amine oxime (HMPAO) intravenously in a dimmed and quiet room. Imaging was performed at least one hour after injection, with a three headed gamma camera equipped with high resolution collimators. A Metz filter (FWHM: 11 mm) was used for processing. Cranial MRI was performed with an imager operating at 1.5 Tesla. Spin-echo T1- and T2-weighted and FLAIR slices were obtained for each individual. In all of the five diseased children we observed pathologic findings both on MRI and Tc-99m HMPAO SPECT. The findings on MRI were mainly features of cerebral and cerebellar atrophy and the observations on Tc-99m HMPAO SPECT were regional perfusion abnormalities. We observed some structural abnormalities on MRI in four of the parents and two of the four healthy siblings. We also noted perfusion abnormalities on Tc-99m HMPAO SPECT in two of the parents and two of the healthy siblings. Because the disease is inherited in an autosomal recessive manner, the parents and the healthy siblings were not supposed to exhibit any demonstrable brain lesions, but the brain perfusion SPECT and MRI examinations clearly revealed multiple lesions in some of the parents and healthy siblings. Detailed neurological examinations of these

  20. Single photon emission computed tomography (SPECT) in seizure disorders in childhood

    International Nuclear Information System (INIS)

    Vles, J.S.H.; Demandt, E.; Ceulemans, B.; de Roo, M.; Casaer, P.J.M.

    1990-01-01

    In 38 children with partial seizures, the EEG, CT and NMR findings were compared to the results obtained with Tc99m HMPAO single photon emission computed tomography (SPECT) in order to determine whether SPECT is a useful adjunct to EEG, CT and NMR in this age group. In 3 out of 7 patients with a normal EEG, SPECT showed focal abnormalities. Nine patients whose EEGs did not show adequate lateralization had an abnormal SPECT which revealed a focus. In 14 out of 21 patients with a normal CT, SPECT showed focal changes in 13 patients and diffuse changes in the other one. In 7 out of 12 patients with a normal NMR, SPECT showed focal abnormalities. Although clinical history and a careful description of the seizures are the most valuable information in partial seizure disorders, SPECT imaging gives valuable additional information, which might target treatment. SPECT was superior to CT and NMR with respect to the depiction of some kind of abnormality. (author)

  1. In vitro assessment of cytotoxicity and labeling efficiency of 99mTc-HMPAO with stromal vascular fraction of adipose tissue

    International Nuclear Information System (INIS)

    Verma, V.K.; Beevi, S.S.; Tabassum, A.; Kumaresan, K.; Kamaraju, R.S.; Arbab, A.S.; Chelluri, L.K.

    2014-01-01

    Introduction: Noninvasive radionuclide imaging of cells using technetium99m-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO) is a potential diagnostic tool for several applications. Herein we aimed to evaluate the labeling efficiency and cellular toxicity of 99m Tc-HMPAO with Stromal Vascular Fraction (SVF) of adipose tissue to develop a process tool for theranostic purposes, in particular imaging cardiac stem cell therapy. Methods: Ten million cells of SVF were labeled with 99m Tc-HMPAO complex and excess radiolabel was cleared off through washing in PBS. The labeling efficiency of 99m Tc-HMPAO was detected in labeled cells and their subsequent supernatant wash using isotope dose calibrator and gamma camera. The cytotoxicity was assessed for the comparative reactive oxygen species (ROS) by H 2 DCFDDA, apoptotic events by annexin-V and TUNEL assay and mitochondrial potential by JC-1. Results: An encouraging labeling efficiency of 33% was observed with 99m Tc-HMPAO complex. The radionuclide labeling of SVF demonstrated significant safety profile as evaluated by apoptotic assays. Conclusion: 99m Tc-HMPAO labeling efficiency of 33% of total SV fraction would produce sufficient radioactive signals that would enable for in vivo tracking of cells by SPECT-CT. The radionuclide did not demonstrate any significant impact on the structural or functional organization of the labeled cells. Our study indicates that SVF can be safely labeled with 99m Tc-HMPAO without adverse cytotoxic events and for its potential role in imaging cardiac stem cell therapy

  2. SPECT in psychiatry; Die Bedeutung der Hirn-SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Kasper, S [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Gruenwald, F [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Danos, P [Psychiatrische Universitaetsklinik, Bonn (Germany); Walter, H [Universitaetsklinik fuer Psychiatrie, Wien (Austria); Klemm, E [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Bruecke, T [Universitaetsklinik fuer Neurologie, Wien (Austria); Podreka, I [Universitaetsklinik fuer Neurologie, Wien (Austria); Biersack, H J [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin

    1994-10-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [Deutsch] In den vergangenen 15 Jahren wurde durch verschiedene methodologische Ansaetze versucht, die biologischen Ursachen psychiatrischer Erkrankungen naeher zu erforschen. Als eine bedeutende Methode hat sich dabei die Single-Photonen-Emissions-Computertomographie (SPECT) herausgestellt. Waehrend die SPECT-Untersuchungen bereits Eingang in die Routinediagnostik bei Demenzen vom Alzheimer-Typ gefunden haben, konnten fuer weitere psychiatrische Erkrankungen noch keine eindeutigen Befunde etabliert werden. Mit der SPECT-Methode ist es jedoch gelungen, funktionelle Veraenderungen des Gehirns von psychiatrischen Erkrankungen darzustellen, wie z.B. Schizophrenie, Depression, Angsterkrankungen bzw. Substanzmissbrauch. In Forschungsprotokollen wird durch die SPECT-Methode versucht, abzuklaeren, inwieweit es moeglich ist, innerhalb der Erkrankungsentitaeten psychiatrischer Erkrankungen oder auch diese uebergreifend eine Subklassifizierung zu finden und evtl. Gehirnsysteme ausfindig zu machen, die mit einer spezifischen

  3. Cerebral fat embolism studied with MRI and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, E. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Namer, I.J. (Inst. of Biophysics, Faculty of Medicine, Louis Pasteur Univ., Strasbourg (France)); Saribas, O. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Aras, T. (Dept. of Nuclear Medicine, Hacettepe Univ. School of Medicine Ankara (Turkey)); Tan, E. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Bekdik, C. (Dept. of Nuclear Medicine, Hacettepe Univ. School of Medicine Ankara (Turkey)); Zileli, T. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey))

    1993-03-01

    In a patient with fat embolism to the brain CT showed no abnormality. MRI performed after recovery from coma, when the patient had aphasia and quadriparesis, demonstrated multiple high signal abnormalities in the white matter on both T1- and T2-weighted images. HMPAO-SPECT showed left-sided hypoperfusion which resolved in parallel with clinical improvement 1 month later. (orig.)

  4. SPECT in patients with cortical visual loss.

    Science.gov (United States)

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  5. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, Torbjoern; Riklund, Katrine Aa. [Umeaa University, Umeaa University Hospital, Department of Radiation Sciences, Diagnostic Radiology, Umeaa (Sweden); Elgh, Eva; Naesman, Birgitta [Umeaa University, Department of Community Medicine and Rehabilitation, Geriatric Medicine, Umeaa (Sweden); Larsson, Anne [Umeaa University, Department of Radiation Sciences, Radiation Physics, Umeaa (Sweden); Nyberg, Lars [Umeaa University, Department of Psychology, Umeaa (Sweden)

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2{+-}4.8 years) with mild AD and 18 healthy elderly (69.4{+-}3.9 years) were included in the study. The subjects were injected with{sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF{sup 99m}Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  6. Reduced contralateral hemispheric flow measured by SPECT in cerebellar lesions

    DEFF Research Database (Denmark)

    Sönmezoğlu, K; Sperling, B; Henriksen, T

    1993-01-01

    Four patients with clinical signs of cerebellar stroke were studied twice by SPECT using 99mTc-HMPAO as a tracer for cerebral blood flow (CBF). When first scanned 6 to 22 days after onset, all had a region of very low CBF in the symptomatic cerebellar hemisphere, and a mild to moderate CBF reduct...

  7. SPECT brain perfusion abnormalities in mild or moderate traumatic brain injury.

    Science.gov (United States)

    Abdel-Dayem, H M; Abu-Judeh, H; Kumar, M; Atay, S; Naddaf, S; El-Zeftawy, H; Luo, J Q

    1998-05-01

    The purpose of this atlas is to present a review of the literature showing the advantages of SPECT brain perfusion imaging (BPI) in mild or moderate traumatic brain injury (TBI) over other morphologic imaging modalities such as x-ray CT or MRI. The authors also present the technical recommendations for SPECT brain perfusion currently practiced at their center. For the radiopharmaceutical of choice, a comparison between early and delayed images using Tc-99m HMPAO and Tc-99m ECD showed that Tc-99m HMPAO is more stable in the brain with no washout over time. Therefore, the authors feel that Tc-99m HMPAO is preferable to Tc-99m ECD. Recommendations regarding standardizing intravenous injection, the acquisition, processing parameters, and interpretation of scans using a ten grade color scale, and use of the cerebellum as the reference organ are presented. SPECT images of 228 patients (age range, 11 to 88; mean, 40.8 years) with mild or moderate TBI and no significant medical history that interfered with the results of the SPECT BP were reviewed. The etiology of the trauma was in the following order of frequency: motor vehicle accidents (45%) followed by blow to the head (36%) and a fall (19%). Frequency of the symptoms was headache (60.9%), memory problems (27.6%), dizziness (26.7%), and sleep disorders (8.7%). Comparison between patients imaged early (3 months) from the time of the accident, showed that early imaging detected more lesions (4.2 abnormal lesions per study compared to 2.7 in those imaged more than 3 months after the accident). Of 41 patients who had mild traumatic injury without loss of consciousness and had normal CT, 28 studies were abnormal. Focal areas of hypoperfusion were seen in 77% (176 patients, 612 lesions) of the group of 228 patients. The sites of abnormalities were in the following order: basal ganglia and thalami, 55.2%, frontal lobes, 23.8%, temporal lobes, 13%, parietal, 3.7%, insular and occipital lobes together, 4.6%.

  8. A review SPECT in neuropsychiatric disorders: neuro biological background, methodology, findings and future perspectives

    International Nuclear Information System (INIS)

    Gardner, Ann; Pagani, Marco

    2003-01-01

    The origin of altered radiotracer uptake and distribution in functional brain imaging studies, often considered to reflect regional cerebral blood flow (rCBF), in psychiatric disorders is unknown. Interpreting the magnitude of changes as changes in the magnitude of neuronal activity may be reasonable during normal circumstances, but less reliable in pathologic states. Results of published 99mTc-HMPAO SPECT studies in unmedicated patients with schizophrenia and major depression are discussed in the light of 99mTc-HMPAO properties, and reported findings of altered cell morphology and biochemistry, with emphasis on energy metabolism. We conclude that the SPECT technique using radiotracers with known biochemical properties will become useful in the understanding of cellular dysfunctions at different phases of neuropsychiatric disorders, and that use of automatic interpretation of three-dimensional volumes will allow for easier identification of regional neural correlates of the different psychiatric symptoms (Au)

  9. A Comparative Study of SPECT, q-EEG and CT in Patients with Mild, Acute Head Trauma

    International Nuclear Information System (INIS)

    Lee, Suk Ho; Kim, Jin Seok; Moon, Hee Seung

    1993-01-01

    Functional cerebral impairments have been verified objectively by brain SPECT and q-EEG (quantitative electroencephalography). Microcerebral circulatory defects without anatomical changes cannot be detected by the brain CT or MRI. Brain SPECT using 99m Tc-HMPAO (Hexamethyl propyleneamine oxime) as a key radioisotope may be accepted as the useful method for identifying functional cerebral impairments. We studied 25 patients with mild head trauma to define whether the SPECT was helpful in detecting cerebral impairment. The SPECT was positive in 23 patients out of 25, q-EEG positive in 16 patients and brain CT was positive in 3 cases. SPECT and q-EEG were more sensitive than CT. SPECT would be more useful method than brain CT to investigate cerebral function after head injury

  10. Acetazolamide stimulation test in patients with unilateral internal carotid artery stenosis using Tc-99m HMPAO SPECT and transcranial doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I. Y.; Na, J. H. [Inha University Hospital, Incheon (Korea, Republic of)

    2007-07-01

    We compared perfusion reserve by acetazolamide (ACZ) challenged brain perfusion SPECT and cerebral vasoreactivity (CVR) by transcranial Doppler sonography (TCD) in patients with unilateral internal carotid artery stenosis. This study was conducted prospectively in 37 consecutive patients with angiographically proven unilateral internal carotid artery stenosis (stenosis> 50%). We estimated % CVR (100? {l_brace}post-ACZ mean velocity (cm/sec) - Pre-ACZ mean velocity (cm/sec){r_brace} / pre-ACZ mean velocity) by TCD. The % CVR was compared with perfusion reserve of SPECT. The % CVR of MCA and ICA was significantly decreased in the ipsilateral side to the carotid stenosis (p<0.05). The CVR impairment was more severe when cerebral infarct is already developed (p<0.01). There was a significant correlation between the degree of carotid stenosis and the CVR (p<0.01). In the area of impaired perfusion reserve on the SPECT, the estimated CVR by TCD was significantly lower (p<0.05), even to the negative value, implying that there is actually steal phenomenon in that area. ACZ challenge can actually decrease cerebral blood flow in the area of impaired perfusion reserve on brain SPECT. So we should be very cautiously performing in ACZ challenge especially when there is a severe carotid stenosis because there is a possibility of developing hemodynamic stroke.

  11. In vitro assessment of cytotoxicity and labeling efficiency of {sup 99m}Tc-HMPAO with stromal vascular fraction of adipose tissue

    Energy Technology Data Exchange (ETDEWEB)

    Verma, V. K.; Beevi, S. S. [Department of Transplant Biology, Immunology and Stem Cell Lab, Global Hospitals, Hyderabad (India); Tabassum, A.; Kumaresan, K. [KK Nuclear Scans, Raj Bhavan Road, Somajiguda, Hyderabad (India); Kamaraju, R. S. [Department of Transplant Biology, Immunology and Stem Cell Lab, Global Hospitals, Hyderabad (India); Arbab, A. S. [Cancer Centre, GA Regents University, Augusta, GA (United States); Chelluri, L.K., E-mail: lkiran@globalhospitalsindia.com [Department of Transplant Biology, Immunology and Stem Cell Lab, Global Hospitals, Hyderabad (India)

    2014-10-15

    Introduction: Noninvasive radionuclide imaging of cells using technetium99m-hexamethylpropyleneamine oxime ({sup 99m}Tc-HMPAO) is a potential diagnostic tool for several applications. Herein we aimed to evaluate the labeling efficiency and cellular toxicity of {sup 99m}Tc-HMPAO with Stromal Vascular Fraction (SVF) of adipose tissue to develop a process tool for theranostic purposes, in particular imaging cardiac stem cell therapy. Methods: Ten million cells of SVF were labeled with {sup 99m}Tc-HMPAO complex and excess radiolabel was cleared off through washing in PBS. The labeling efficiency of {sup 99m}Tc-HMPAO was detected in labeled cells and their subsequent supernatant wash using isotope dose calibrator and gamma camera. The cytotoxicity was assessed for the comparative reactive oxygen species (ROS) by H{sub 2}DCFDDA, apoptotic events by annexin-V and TUNEL assay and mitochondrial potential by JC-1. Results: An encouraging labeling efficiency of 33% was observed with {sup 99m}Tc-HMPAO complex. The radionuclide labeling of SVF demonstrated significant safety profile as evaluated by apoptotic assays. Conclusion: {sup 99m}Tc-HMPAO labeling efficiency of 33% of total SV fraction would produce sufficient radioactive signals that would enable for in vivo tracking of cells by SPECT-CT. The radionuclide did not demonstrate any significant impact on the structural or functional organization of the labeled cells. Our study indicates that SVF can be safely labeled with {sup 99m}Tc-HMPAO without adverse cytotoxic events and for its potential role in imaging cardiac stem cell therapy.

  12. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia

    International Nuclear Information System (INIS)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo; Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi.

    1990-01-01

    To evaluate the efficacy of tests for selecting patients with hemodynamic compromise, measurement of cerebral blood volume (CBV) with 99m Tc-RBC single photon emission computed tomography (SPECT) was performed in thirteen patients with occlusive cerebrovascular disease, and was compared with results obtained by 133 Xe SPECT and acetazolamide (Diamox) test. All patients in our study suffered TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery, although plain CT scan or MRI revealed no or, if any, only localized infarcted lesions. Regional cerebral blood volume (rCBV) was measured with 99m Tc-RBC SPECT and regional cerebral blood flow (rCBF) was measured with 133 Xe SPECT before and after intravenous injection of 10 - 12 mg/kg acetazolamide (Diamox). Our results suggest that the ipsilateral rCBV/rCBF (mean transit time) is a more sensitive index of the cerebral perfusion reserve than the use of only rCBV or rCBF of the ipsilateral hemisphere. Also, the ipsilateral rCBV/rCBF is significantly correlated (r= -0.72) with the Diamox reactivity of rCBF, which is considered to represent the cerebral vasodilatory capacity in patients with chronic cerebral ischemia. Postoperative SPECT study revealed remarkable improvement of ipsilateral rCBV/rCBF and Diamox reactivity in four patients who underwent EC/IC bypass surgery to improve the hemodynamic compromise. In conclusion, our results suggest that the measurement of rCBV/rCBF with 133 Xe SPECT and 99m Tc-RBC SPECT is useful for detecting the hemodynamic compromise in patients with occlusive cerebrovascular disease. (author)

  13. Cerebral blood flow assessed by brain SPECT with 99mTc-HMPAO utilising the acetazolamide test in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Lass, P.; Romanowicz, G.; Koseda-Dragan, M.

    1998-01-01

    Background: Cerebrovascular diseases are one of the most important complications of systemic lupus erythematosus (SLE). The diagnostic imaging of neuropsychiatric SLE complications presents many problems. This study was undertaken to investigate cerebral blood flow char s and its reactivity to hypercapnia by means of acetazolamide test in SLE patients. Methods: Brain SPECT studies using 99mTc-HMPAO were performed in 50 patients with SLE. Acetazolamide test was performed in 35 patients 3 days after the baseline study by means of repetitive scanning 20 min after i.v. injection of 1.0 g of acetazolamide. Results: Significant interhemispheric hypoperfusion areas were shown in 76.3% of all patients, 83.8% symptomatic and 63.1% asymptomatic. Patients with antiphospholipid syndrome showed multifocal perfusion deficits. The reaction of cerebral perfusion to acetazolamide was heterogenous and showed increase, decrease, no change or mixed reaction of baseline-study-found focal hypoperfusion. Acetazolamide test revealed hypoperfusion in two patients with normal baseline study. MRI scanning revealed cerebral lesions in 41% of patients. Conclusions: CBF asymmetries in symptomatic and asymptomatic patients with SLE are frequent. Regional CBF alterations seem to be different in patients with and without antiphospholipid syndrome. The part of the patients with SLE shows no or paradoxically inversed reaction to acetazolamide. (author)

  14. Single-photon emission computed tomography (SPECT) in oediatric migraine

    International Nuclear Information System (INIS)

    Battistella, P.A.; Pitassi, I.; Ruffilli, R.; Boniver, C.; Suppiej, A.; Casara, G.

    1989-01-01

    Cerebral blood flow in pediatric patients suffering from different types of migraine is analyzed by SPECT with 99m Tc HM-PAO, during the pain free intervals. The results indicate that such studies may give further information toward the understanding of common and classic forms of migraine and the difference in the CBF patterns of these forms support the hypothesis of a possible different pathogenesis. (H.W.). 13 refs.; 1 tab

  15. Diagnosis of hemodynamic compromise in patients with chronic cerebral ischemia

    International Nuclear Information System (INIS)

    Kuroda, Satoshi; Sakuragi, Mitsugi; Motomiya, Mineo; Nakagawa, Tango; Mitsumori, Kenji; Tsuru, Mitsuo; Takigawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi.

    1990-01-01

    Tests using 133 Xe inhalation method and single photon emission computed tomography (SPECT) with acetazolamide (Diamox) were performed in 23 patients with chronic cerebral ischemia, before and after extracranial-intracranial bypass surgery or carotid-endarterectomy. All patients complained of TIA, RIND, or minor completed stroke. Cerebral angiography demonstrated severe stenosis or occlusion in the ipsilateral internal carotid artery or middle cerebral artery. Cerebral blood flow (CBF) was measured with 133 Xe SPECT, and was measured 15 minutes after intravenous administration of 10-12 mg/kg Diamox, which is known as a cerebral vasodilatory agent (Diamox test). Our results revealed that all patients could be divided into four types according to their resting rCBF and Diamox reactivity. The patients who had normal resting rCBF and normal Diamox reactivity (type 1) were considered to have well-developed collateral circulation and normal cerebral perfusion pressure (CPP) in spite of severe occlusive lesions in the carotid system. Moderate vasodilation due to reduced CPP was considered to occur in patients who had normal resting rCBF and decreased Diamox reactivity (type 2). The resting rCBF remained unchanged, but Diamox reactivity improved to normal after surgery in the patients of type 2, which indicated the improvement of CPP and the resolution of the autoregulatory vasodilation. Maximum vasodilation or dysautoregulation was considered to occur due to the inadequate collateral flow and the severely reduced CPP in patients whose findings revealed decrease in the resting rCBF and impaired Diamox reactivity (type 3). Remarkable improvement was seen in both resting rCBF and Diamox reactivity after surgery in the patients of type 3. In the patients who had decreased resting rCBF and normal Diamox reactivity (type 4), the decreased resting rCBF was considered to result from the reduction in metabolic demand because of irreversible ischemic neuronal damage. (J.P.N.)

  16. Crossed cerebellar hyperperfusion on ictal Tc-99m HMPAO brain SPECT: clinical significance for differentiation of mesial or lateral temporal lobe epilepsy and related factors for development

    International Nuclear Information System (INIS)

    Park, Soon Ah; Sohn, Myung Hee; Lim, Seok Tae; Lee, Dong Soo; Lee, Sang Gun; Kim, Seok Ki; Jang, Myoung Jin; Chung, June Key; Lee, Myung Chul

    2000-01-01

    The aim of this study was to determine whether crossed cerebellar hyperperfusion (CCH) was helpful in discriminating mesial from lateral temporal lobe epilepsy (TLE) and what other factors were related in the development of CCH on ictal brain SPECT. We conducted retrospective analysis in 59 patients with TLE (M:41, F:18; 27.4±7.8 years old; mesial TLE: 51, lateral TLE: 8), which was confirmed by invasive EEG and surgical outcome (Engel class 1, 2). All the patients underwent ictal Tc-99m HMPAO brain SPECT and their injection time from ictal EEG onset on video EEG monitoring ranged from 11 sec to 75 sec (32.6±19.5 sec) in 39 patients. Multiple factors including age, TLE subtype (mesial TLE or lateral TLE), propatation pattern (hyperperfusion localized to temporal lobes, spread to adjacent lobes or contralateral hemisphere) and injection time were evaluated for their relationship with CCH using multiple logistic regression analysis CCH was observed in 18 among 59 patients. CCH developed in 29% (15/51) of mesial TLE patients and 38% (3/8) of lateral TLE patients. CCH was associated with propagation pattern; no CCH (0/13) in patients with hyperperfusion localized to temporal lobe, 30% (7/23) in patients with propagation to adjacent lobes, 48% (11/23) to contralateral hemisphere. Multiple logistic regression analysis revealed that propagation pattern (p=3D0.01) and age (p=3D0.02) were related to the development of CCH. Crossed cerebellar hyperperfusion in ictal brain SPECT did not help differentiate mesial from lateral remporal lobe epilepsy. Crossed cerebellar hyperperfusion was associated with propagation pattern of temporal lobe epilepsy and age.=20

  17. Crossed cerebellar hyperperfusion on ictal Tc-99m HMPAO brain SPECT: clinical significance for differentiation of mesial or lateral temporal lobe epilepsy and related factors for development

    Energy Technology Data Exchange (ETDEWEB)

    Park, Soon Ah; Sohn, Myung Hee; Lim, Seok Tae [Chonbuk National Univ. School of Medicine, Chonju (Korea, Republic of); Lee, Dong Soo; Lee, Sang Gun; Kim, Seok Ki; Jang, Myoung Jin; Chung, June Key; Lee, Myung Chul [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2000-08-01

    The aim of this study was to determine whether crossed cerebellar hyperperfusion (CCH) was helpful in discriminating mesial from lateral temporal lobe epilepsy (TLE) and what other factors were related in the development of CCH on ictal brain SPECT. We conducted retrospective analysis in 59 patients with TLE (M:41, F:18; 27.4{+-}7.8 years old; mesial TLE: 51, lateral TLE: 8), which was confirmed by invasive EEG and surgical outcome (Engel class 1, 2). All the patients underwent ictal Tc-99m HMPAO brain SPECT and their injection time from ictal EEG onset on video EEG monitoring ranged from 11 sec to 75 sec (32.6{+-}19.5 sec) in 39 patients. Multiple factors including age, TLE subtype (mesial TLE or lateral TLE), propatation pattern (hyperperfusion localized to temporal lobes, spread to adjacent lobes or contralateral hemisphere) and injection time were evaluated for their relationship with CCH using multiple logistic regression analysis CCH was observed in 18 among 59 patients. CCH developed in 29% (15/51) of mesial TLE patients and 38% (3/8) of lateral TLE patients. CCH was associated with propagation pattern; no CCH (0/13) in patients with hyperperfusion localized to temporal lobe, 30% (7/23) in patients with propagation to adjacent lobes, 48% (11/23) to contralateral hemisphere. Multiple logistic regression analysis revealed that propagation pattern (p=3D0.01) and age (p=3D0.02) were related to the development of CCH. Crossed cerebellar hyperperfusion in ictal brain SPECT did not help differentiate mesial from lateral remporal lobe epilepsy. Crossed cerebellar hyperperfusion was associated with propagation pattern of temporal lobe epilepsy and age.

  18. Technetium SPECT agents for imaging heart and brain

    International Nuclear Information System (INIS)

    Linder, K.E.

    1990-01-01

    One major goal of radiopharmaceutical research has been the development of technetium-based perfusion tracers for SPECT imaging of the heart and brain. The recent clinical introduction of the technetium complexes HM-PAO, ECD and DMG-2MP for brain imaging, and of CDO-MEB and MIBI for heart imaging promises to revolutionize the field of nuclear medicine. All of these agents appear to localize in the target tissue in proportion to blood flow, but their mechanisms of localization and/or retention may differ quite widely. In this talk, a survey of the new technetium SPECT agents will be presented. The inorganic and biological chemistry of these complexes, mechanisms of uptake and retention, QSAR studies, and potential clinical applications are discussed

  19. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    International Nuclear Information System (INIS)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R.; Lindenau, M.; Stodieck, S.; Fiehler, J.; Heese, O.

    2008-01-01

    Ictal perfusion SPECT with either 9 9mTc-hexamethylpropylene amine oxime (HMPAO) or 9 9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case

  20. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Nuclear Medicine; Lindenau, M.; Stodieck, S. [Protestant Hospital Alsterdorf, Hamburg (Germany). Dept. of Neurology and Epileptology; Fiehler, J. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Neuroradiology; Heese, O. [Univ. Medical Center Hamburg-Eppendorf (Germany). Neurological Surgery

    2008-07-01

    Ictal perfusion SPECT with either {sup 9}9mTc-hexamethylpropylene amine oxime (HMPAO) or {sup 9}9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case.

  1. Clinical Significance of Brain SPECT in Zipeprol Abusers

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Dai Ok; Kim, Jae Phil; Kim, Deog Yoon; Yang, Hyung In; Koh, Eun Mi; Kim, Kwang Won; Choi, Young Kil [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1993-03-15

    Drug abuse is widespread in worldwide and has been associated with neurologic complication. Zipeprol is one of drugs which been abused for psychological satisfaction in some adolescents. This agent is non-opioid antitussive agent, which is not legally considered as being capable of creating dependence or abuse liability at therapeutic serum levels. But it has been reported that acute or chronic overdose create neurologic complication such as convulsion as well as dependence. Recently we experienced six zipeprol abusers who admitted due to convulsion and variable neurologic symptoms. The aim of our study was to determine the role of Tc-99m- HMPAO brain SPECT in those patients. EEG and brain CT showed no abnormal finding, but brain SPECT showed focal or multiple perfusion abnormalities in frontal, parietal, occipital cortex, basal ganglia, thalamus and especially at temporal cortex. These results suggest that brain SPECT may be a useful diagnostic tool to evaluate the cerebral dysfunction induced by zipeprol abuse.

  2. Clinical Significance of Brain SPECT in Zipeprol Abusers

    International Nuclear Information System (INIS)

    Cho, Dai Ok; Kim, Jae Phil; Kim, Deog Yoon; Yang, Hyung In; Koh, Eun Mi; Kim, Kwang Won; Choi, Young Kil

    1993-01-01

    Drug abuse is widespread in worldwide and has been associated with neurologic complication. Zipeprol is one of drugs which been abused for psychological satisfaction in some adolescents. This agent is non-opioid antitussive agent, which is not legally considered as being capable of creating dependence or abuse liability at therapeutic serum levels. But it has been reported that acute or chronic overdose create neurologic complication such as convulsion as well as dependence. Recently we experienced six zipeprol abusers who admitted due to convulsion and variable neurologic symptoms. The aim of our study was to determine the role of Tc-99m- HMPAO brain SPECT in those patients. EEG and brain CT showed no abnormal finding, but brain SPECT showed focal or multiple perfusion abnormalities in frontal, parietal, occipital cortex, basal ganglia, thalamus and especially at temporal cortex. These results suggest that brain SPECT may be a useful diagnostic tool to evaluate the cerebral dysfunction induced by zipeprol abuse.

  3. Differences at brain SPECT between depressed females with and without adult ADHD and healthy controls: etiological considerations

    Directory of Open Access Journals (Sweden)

    Jacobsson Hans

    2009-09-01

    Full Text Available Abstract Background Comorbidity between Attention Deficit Hyperactivity Disorder (ADHD and mood disorders is common. Alterations of the cerebellum and frontal regions have been reported in neuro-imaging studies of ADHD and major depression. Methods Thirty chronically depressed adult females of whom 16 had scores below, and 14 scores above, cut-offs on the 25-items Wender Utah Retrospective Scale (WURS-25 and the Wender-Reimherr Adult Attention Deficit Disorder Scale (WRAADDS were divided into subgroups designated "Depression" and "Depression + ADHD", respectively. Twenty-one of the patients had some audiological symptom, tinnitus and/or hearing impairment. The patients were investigated with other rating scales and 99mTc-HMPAO SPECT. Controls for 99mTc-HMPAO SPECT were 16 healthy females. SPECT was analyzed by both statistical parametric mapping (SPM2 and the computerized brain atlas (CBA. Discriminant analysis was performed on the volumes of interest generated by the CBA, and on the scores from rating scales with the highest group differences. Results The mean score of a depression rating scale (MADRS-S was significantly lower in the "Depression" subgroup compared to in the "Depression + ADHD" subgroup. There was significantly decreased tracer uptake within the bilateral cerebellum at both SPM and CBA in the "Depression + ADHD" subgroup compared to in the controls. No decrease of cerebellar tracer uptake was observed in "Depression". Significantly increased tracer uptake was found at SPM within some bilateral frontal regions (Brodmann areas 8, 9, 10, 32 in the "Depression + ADHD" subgroup compared to in "Depression". An accuracy of 100% was obtained for the discrimination between the patient groups when thalamic uptake was used in the analysis along with scores from Socialization and Impulsivity scales. Conclusion The findings confirm the previous observation of a cerebellar involvement in ADHD. Higher bilateral frontal 99mTc-HMPAO uptake in

  4. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Kamoya, Masatoshi

    2001-01-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  5. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kamoya, Masatoshi [Kanazawa Medical Univ., Ishikawa (Japan)

    2001-03-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  6. The Performance of Ictal Brain SPECT for Localizing Epileptogenic Foci in Temporal Lobe epilepsies

    International Nuclear Information System (INIS)

    Kim, Eun Sil; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Chang, Kee Hyun; Lee, Sang Kun; Chung, Chun Kee

    1995-01-01

    Anterior temporal lobectomy has become a widely used respective surgery in patients with medically intractable temporal lobe epilepsies. Prerequisites of this resection include the accurate localization of the epileptogenic focus and the determination that the proposed resection would not result in unacceptable postoperative memory or language deficits. The purpose of this study was to evaluate the performance of ictal SPECT compared to MRI findings for localization of epileptogenic foci in this group of patients. 11 patients who had been anterior temporal oral lobectomy were evaluated with ictal 99m Tc-HMPAO SPECT and MRI. MRI showed 8/11(73%) concordant lesion to the side of surgery and ictal SPECT also showed 8/11(73%) concordant hyperperfusion. In 3 cases with incorrect or nonlocalizing findings of MRI, ictal SPECT showed concordant hyperperfusion. In 2 cases confirmed by pre-resectional invasive EEG, MRI showed bilateral and contralateral lesion but ictal SPECT showed concordant hyperperfusion. 3 delayed injection of ictal SPECT showed discordant hyperperfusion. Thus, ictal SPECT was a useful method for localizing epileptogenic foci in temporal lobe epilepsies and appeared complementay to MRI.

  7. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    Science.gov (United States)

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts

  8. Regional cerebral blood flow changes as assessed by 99m-Tc-HMPAO SPECT in 70 Unipolar Depressed patients at rest

    International Nuclear Information System (INIS)

    Pagani, M.M.E.; Sanchez-Crespo, A.; Jonsson, C.; Jacobsson, H.; Waegner, A.; Larsson, S.A.; Gardner, A.; Haellstroem, T.; Salmaso, D.

    2002-01-01

    Aim: Alterations in excitatory or inhibitory signals between cortical and sub-cortical regions in patients with unipolar depression (MDD) may be assessed by investigating changes in regional cerebral blood flow (rCBF). Regions with abnormal metabolic activity might participate in neural networks and affect the rCBF distribution in functionally connected structures. The aim of this study was to identify the brain regions showing rCBF changes in MDD by means of SPECT and Principal Component Analysis (PCA). Materials and Methods: The rCBF distributions in 70 MDD and 66 control (CTR) subjects, at rest, were compared. 99m Tc-HMPAO SPECT, using a three-headed gamma camera, was performed and the uptake in 27 functional bilateral sub-volumes of the brain was assessed by a standardised digitalised brain atlas. Data were grouped into functional regions by means of PCA analysis performed on all 136 individuals. Analysis of variance (ANOVA) was used to test the significance of the differences in flow in such functional regions. Results: In the global analysis, rCBF significantly differed between groups (0.02). There were also significant hemispheres x groups interaction (p<0.003) and gender difference (p=0.003), with right hemisphere rCBF specifically increased in MDD and females showing a higher CBF. PCA identified 11 anatomo-functional regions that interacted with groups (p<0.001) and gender (p<0.001). As compared to CTR, MDD rCBF increased, bilaterally, in the right associative temporo-parietal cortex (p<0.007), in right frontal cortex and prefrontal cortex (p=0.002), in the temporal poles (p<0.03) and in thalamus and basal ganglia (p<0.001). Conclusions: Higher rCBF in MDD at rest was found in 4 clusters of regions sharing close anatomical and functional relationships. These regions represented large parts of the right hemisphere and the downstream central structures. These findings confirm rCBF changes in unipolar depressive disorders, suggest mutual rCBF relationships

  9. Relative hyperperfusion by SPECT in a family with a presenilin 1 (T245P) mutation.

    Science.gov (United States)

    Edwards-Lee, Terri; Wen, Johnny; Chung, Julia A; Vasinrapee, Panukorn; Mishkin, Frederick S

    2008-01-01

    Clinical characteristics of autosomal dominant Alzheimer's disease often differ clinically from sporadic disease with the onset of seizures, spasticity and myoclonus early in the disease course. Similarly imaging characteristics may also differ. We report the findings of relative hyperperfusion by Tc-99m HMPAO SPECT in the medial orbitofrontal cortex and anterior temporal lobe in four affected family members carrying a presenilin 1 mutation. SPECT of the four individuals was compared to an age-matched normal database. We speculate that the findings of relative medial orbitofrontal and anterior temporal lobe hyperperfusion may be a marker of early onset Alzheimer's disease in this family.

  10. 99mTc-HMPAO Labelled WBC Scan in Experimental Abscess by Labelling Autologous Leukocytes with In-House-Synthesized HMPAO

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Shin, Hyung Sik; Ahn, Curie; Chung, June Key; Lee, Myung Chul; Choi, Kang Won; Koh, Chang Soon; Jung, Jae Min; Chung, Eun Ju

    1991-01-01

    With HMPAO we have synthesized in our laboratory, we labelled 99m Tc to canine leukocytes. Experimental abscess made by subcutaneous injection with Staphylococcus aureus was imaged with these 99m Tc labelled leukocytes. Labelling efficiency of HMPAO with 99m Tc was 66.2% ± 14.6% (N=9). Labelling efficiency of leukocytes with 99m Tc-HMPAO was 54% ± 7.79 (N=7). Cell bound radio activity in 99m Tc-HMPAO labelled leukocytes was around 80%. when these cells were incubated in plasma in vitro at 37 .deg. C for 5 hours. In vivo cell bound activity was over 80% at 24 hours after injection. One day and four days after inoculation, uptake at the inflammatory focus was found with 99m Tc labelled leukocytes. Uptake showed up in 4 hour image, and the uptake at the lesion was most prominent in 24 hour image. These findings show that in-house-synthesized HMPAO could be used for labelling leukocytes with 99m Tc, and that 99m Tc-HMPAO-labelled leukocytes were so stable and viable that inflammatory focus could be visualized with these 99m Tc-labelled leukocytes.

  11. SPECT and PET in cerebrovascular diseases. SPECT und PET bei cerebrovaskulaeren Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, W.H. (Herzzentrum Nordrhein-Westfalen, Bad Oeynhausen (Germany). Inst. fuer Nuklearmedizin)

    1993-02-01

    Investigations using recently emerged perfusion tracers for SPECT, Tc-99m-HMPAO in particular, and studies of local glucose metabolism and oxygen utilisation with PET have deepened our knowledge of the pathophysiology in development and in the sequel of stroke. Studies of local cerebral blood flow and cerebrovascular reserve capacity are indicated in case of neurological symptoms suspected to be caused by transient ischemic attacks or in case of significant narrowing of the cerebral arteries. PET investigations of local metabolism (at the present state) are indicated in patients with incompleted stroke or with infarction and extended ischemic border zone. The differential diagnosis between multi-infarct-dementia and primarily neurodegenerative dementias is facilitated, in some individuals, by the characteristic topography of reduced flow. (orig./MG).

  12. Brain SPECT in the pre-surgical evaluation of epileptic patients

    International Nuclear Information System (INIS)

    Buchpiguel, C.A.; Cukiert, A.; Hironaka, F.H.; Cerri, G.G.; Magalhaes, A.E.A.; Marino Junior, R.

    1992-01-01

    Fifteen adult epileptic patients were studied pre-operatively using a rotational scintillation camera interfaced to a dedicated computer. The tomographic images were obtained 15 minutes after intravenous injection of 99 m Tc-HMPAO. All had MRI scanning and intensive EEG monitoring which generally included seizure recording. Five patients had progressive lesions (3 meningiomas, 2 astrocytomas). In 10 patients, neuroradiological studies did not show the presence of progressive lesions (2 normal scans and 8 cases with inactive lesions). Two patients with meningioma showed hypoperfusion at the lesion site while the third patient had a marked hypoperfusion which might correlate with the clinical diagnosis of epilepsia partialis continua. In the astrocytoma patients SPECT scans showed hypoperfusion at the lesion site. Data obtained from the 10 patients without progressive CNS lesions showed: in 4, SPECT findings correlated well with the anatomical findings; in 5 instances, SPECT was able to disclose additional functional deficits; in one case, there was no SPECT correlate of a discrete anatomical lesion. In 5 of these cases with no progressive lesions (n=10) SPECT findings were useful as a complementary tool in determining the clinical or surgical management of these patients. Despite the small number and heterogeneity of the present sample, SPECT seems to be an useful tool as part of the clinical workup of epileptic who are candidates for epilepsy surgery. (author)

  13. Brain Perfusion SPECT Imaging in Sturge - Weber Syndrome : Comparison with MR Imaging

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Choi, Yun Young; Moon, Dae Hyuk; Yang, Seoung Oh; Ko, Tae Sung; Yoo, Shi Joon; Lee, Hee Kyung

    1996-01-01

    The purpose of this study was evaluate the characteristic perfusion changes in patients with Sturge-Weber syndrome by comparison of the findings of brain MR images and perfusion SPECT images. 99m Tc-HMPAO or 99m Tc-ECD interictal brain SPECTs were performed on 5 pediatric patients with Struge-Weber syndrome within 2 weeks after MR imaging. Brain SPECTs of three patients without calcification showed diminished perfusion in the affected area on MR image. A 3 month-old patient without brain atrophy or calcification demonstrated paradoxical hyperperfusion in the affected hemisphere, and follow-up perfusion SPECT revealed decreased perfusion in the same area. The other patient with advanced calcified lesion and atrophy on MR image showed diffusely decreased perfusion in the affected hemisphere, but a focal area of increased perfusion was also noted in the ipsilateral temporal lobe on SPECT. In conclusion, brain perfusion of the affected area of Sturge-Weber syndrome patients was usually diminished, but early or advanced patients may show paradoxical diffuse or focal hyperperfusion in the affected hemisphere. Further studies are needed for better understanding of these perfusion changes and pathophysiology of Struge-Weber syndrome.

  14. Technetium-99m-HMPAO SPECT in patients with hemiconvulsions followed by Todd`s paralysis

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, M.; Sejima, Hitoshi; Ozasa, Hiroshi; Yamaguchi, Seiji [Department of Pediatrics, Shimane Medical University, 89-1 Enya-cho, Izumo, Shimane 693 (Japan)

    1998-02-01

    We performed technetium-99m-hexamethylpropylene- amineoxime (Tc-HMPAO) single photon emission computed tomography in two patients with prolonged hemiconvulsions followed by transient hemiparesis (Todd`s paralysis). In both cases, a prolonged post-ictal cerebral hyperperfusion state of approximately 24 h was observed, even after the neurological deficits had resolved. The cerebral hyperperfusion in both cases was of much longer duration than that in previously reported cases of single and uncomplicated focal seizures. The prolonged cerebral hyperperfusion might have been due to impairment of the cerebrovascular autoregulation in seizures followed by Todd`s paralysis. (orig.) With 2 figs., 9 refs.

  15. Pinhole SPECT: high resolution imaging of brain tumours in small laboratory animals

    International Nuclear Information System (INIS)

    Franceschim, M.; Bokulic, T.; Kusic, Z.; Strand, S.E.; Erlandsson, K.

    1994-01-01

    The performance properties of pinhole SPECT and the application of this technology to evaluate radionuclide uptake in brain in small laboratory animals were investigated. System sensitivity and spatial resolution measurements of a rotating scintillation camera system were made for a low energy pinhole collimator equipped with 2.0 mm aperture pinhole insert. Projection data were acquired at 4 degree increments over 360 degrees in the step and shoot mode using a 4.5 cm radius of rotation. Pinhole planar and SPECT imaging were obtained to evaluate regional uptake of Tl-201, Tc-99m-MIBI, Tc-99m-HMPAO and Tc-99m-DTPA in tumor and control regions of the brain in a primary brain tumor model in Fisher 344 rats. Pinhole SPECT images were reconstructed using a modified cone- beam algorithm developed from a two dimensional fan-beam filtered backprojection algorithm. The reconstructed transaxial resolution of 2.8 FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0 mm pinhole collimator aperture were measured. Tumor to non-tumor uptake ratios at 19-28 days post tumor cell inoculation varied by a factor > 20:1 on SPECT images. Pinhole SPECT provides an important new approach for performing high resolution imaging: the resolution properties of pinhole SPECT are superior to those which have been achieved with conventional SPECT or PET imaging technologies. (author)

  16. Stabilization of Tc-99m D,L-HMPAO preparations as a leucocyte labelling agent

    International Nuclear Information System (INIS)

    Kao, C.H.; Huang, W.T.; Tsai, C.S.

    1998-01-01

    An attempt was made to use stabilized Tc-99m D,L-HMPAO (S-HMPAO) to label leucocytes. The radiochemical purity of Tc-99m D,L-HMPAO, labelling efficiency of leucocytes, cell viability of labelled leucocytes, and stability of S-HMPAO labelled leucocytes were calculated. In comparison with commercial Tc-99m D,L-HMPAO (C-HMPAO) without stabilization, immediately, at 0.5, 1, 2, 4, and 6 h after HMPAO preparation, the radiochemical purity of S-HMPAO and the labelling efficiencies of S-HMPAO labelled leucocytes were higher. S-HMPAO is more stable than C-HMPAO and can provide higher leucocyte labelling efficiency. S-HMPAO, therefore, has the potential to replace C-HMPAO as a leucocyte-labelling agent

  17. 99mTc-HMPAO-labelled leucocyte scintigraphy in the diagnosis of infection after total knee replacement arthroplasty

    International Nuclear Information System (INIS)

    Park, Dong Rib; Kim, Jae Seung; Ryu, Jin Sook; Moon, Dae Hyuk; Bin, Seong Il; Cho, Woo Shin; Lee, Hee Kyung

    1999-01-01

    This study was performed to evaluate the usefulness of 99m Tc-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy. The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age: 65 years) who had total knee replacement arthroplasty. After injection of 99m Tc-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection: Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positive, one false positive and three true negative in Group B, and six true negatives and two false positive in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively. 99m Tc-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity

  18. Reduced hypothalamic blood flow after radiation treatment of nasopharyngeal cancer: SPECT studies in 34 patients

    International Nuclear Information System (INIS)

    Chieng, P.U.; Huang, T.S.; Chang, C.C.; Chong, P.N.; Tien, R.D.; Su, C.T.

    1991-01-01

    To determine the effect of cranial irradiation on hypothalamic blood flow, the authors performed 44 regional cerebral blood flow studies with 99mTc hexamethyl propyleneamine oxime (HMPAO) single-photon emission CT (SPECT) on four normal volunteers and 34 patients with pathologically proved nasopharyngeal cancer. Twenty-three men and 15 women, 30-65 years old, were divided into four study groups: group 1 served as a control and consisted of four normal volunteers and six patients studied prior to cranial irradiation; group 2 patients had cranial irradiation half a year before the SPECT study (n = 12, one from group 1); group 3 patients were irradiated 1 year before the study (n = 13, three from group 1 and two from group 2); and group 4 patients were irradiated at least 5 years before SPECT imaging (n = 9). Six patients were studied twice. Quantification of the 99mTc-HMPAO brain SPECT studies was done separately by three radiologists to obtain the hypothalamus/occipital (H/O) and hypothalamus/parasagittal (H/P) ratios. Endocrinologic studies were performed in all cases and the hypothalamus-thyrotroph-thyroid, hypothalamus-gonadotroph-testis (ovary), hypothalamus-lactotroph, hypothalamus-somatotroph, and hypothalamus-corticotroph-adrenal axes were evaluated separately. They determined that regional hypothalamic blood flow was reduced after cranial irradiation in patients with nasopharyngeal cancer. The H/O ratio of groups 3 and 4 did not differ from that of group 2 (one-half year after cranial irradiation). The H/O ratio was significantly reduced 6 months and 1 year after cranial irradiation; mean ± SD = 0.5801 ± 0.0829 (p less than .025), 0.5725 ± 0.0791 (p less than .01) versus 0.6477 ± 0.0458 before cranial irradiation, respectively

  19. The EEG, CT and Tc-99m HMPAO SPECT study in patients with epilepsy

    International Nuclear Information System (INIS)

    Tovuudorj, A.; Tsagaankhuu, G.; Onkhuudai, P.; Tsevelmaa, L.; Sereegotov, E.; Enkhtuya, B.

    2007-01-01

    Full text: We have put an objective of studying the EEG and neuroimaging diagnostic indexes (CT, SPECT) in patients with partial seizures during interictal period. Methods: In our study a total of 35 cases were included (20 male and 15 females). In EEG studies we used the diagnostics methodology elaborated by L.R.Zenkov (1996) and in SPECT study by Payne JK (1991) and in CT investigation by Chermissan V.M (2001). Results: By EEG study the cases of interictal period of partial seizure were mostly revealed in the form of sharp waves in temporal lobe (47.62.5%). By CT study the 18 (51.4 ± 2.5 %) cases of partial seizure with normal index, 12 (34.3 ± 1.8 %) cases with dilatation of ventricles and 5 (14.3 ± 2.1%) cases of cerebral atrophy. In SPECT investigation we identified 8 (22.81.8%) cases with normal brain blood flow supply and 27 (77.2 2.0%) cases with variable degrees of hypoperfusion (AI) in the temporal lobe was reaching 233.9% (p<0.01). Conclusion: 1. On EEG analysis during interictal period of partial seizures, there were prevailing sharp-waves (47.6 ± 2.5%) at temporal location of a hemispheres. 2. The brain CT investigation during epilepsy mostly revealed the normal indexes 3. By analyzing brain SPECT during the interictal period of seizures, there were prevailing hypoperfusion degrees (AI) of blood flow to reach 23.0 ± 3.9%. (author)

  20. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    International Nuclear Information System (INIS)

    Sinnatamby, R.; Antoun, N.A.; Freer, C.E.L.; Miles, K.A.; Hodges, J.R.

    1996-01-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using 99m Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  1. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sinnatamby, R. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Antoun, N.A. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Freer, C.E.L. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Miles, K.A. [Dept. of Nuclear Medicine, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Hodges, J.R. [Dept. of Neurology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom)

    1996-04-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using {sup 99m}Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  2. {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy in the diagnosis of infection after total knee replacement arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Rib [College of Medicine, Kunkuk Univ., Seoul (Korea, Republic of); Kim, Jae Seung; Ryu, Jin Sook; Moon, Dae Hyuk; Bin, Seong Il; Cho, Woo Shin; Lee, Hee Kyung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    1999-08-01

    This study was performed to evaluate the usefulness of {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy. The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age: 65 years) who had total knee replacement arthroplasty. After injection of {sup 99m}Tc-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection: Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positive, one false positive and three true negative in Group B, and six true negatives and two false positive in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively. {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  3. SPECT/CT for staging and treatment monitoring in oncology. Applications in differentiated thyroid cancer and liver tumors; SPECT/CT zum initialen Staging und Therapiemonitoring in der Onkologie. Indikationen beim differenzierten Schilddruesenkarzinom und bei Lebertumoren

    Energy Technology Data Exchange (ETDEWEB)

    Weber, K.; Berger, F.; Reiser, M.F. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Innenstadt, Institut fuer Klinische Radiologie, Muenchen (Germany); Mustafa, M.; Bartenstein, P.; Haug, A. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Campus Grosshadern, Klinik und Poliklinik fuer Nuklearmedizin, Muenchen (Germany)

    2012-07-15

    and SPECT/CT provides more accurate imaging of the arterial supply of the liver and of potential outflows of micro-spheres into other organs. SPECT/CT allows evaluation and quantification of the uptake of liver tumors. Improved postablative staging in patients with differentiated thyroid cancer by SPECT/CT in comparison to radioiodine whole body scans can be achieved. Improved planning and monitoring of SIRT therapies utilizing SPECT/CT leads to optimized therapeutic doses within liver lesions. Integration of SPECT/CT into the clinical standard for postablative staging in patients with DTC is recommended as well as utilization of SPECT/CT during the planning process, for dose calculation and treatment monitoring of SIRT therapies. (orig.) [German] In den letzten Jahren hat die Hybridbildgebung mit Verbindung von funktioneller und morphologischer Information zur Diagnostik zahlreicher Erkrankungen zunehmend an Bedeutung gewonnen. Bei Patienten mit differenziertem Schilddruesenkarzinom (DTC) wird nach erfolgter Radiojodtherapie (RJT) ein planares Ganzkoerperszintigramm zum Staging durchgefuehrt. Die diagnostische Genauigkeit dieser szintigraphischen Methode ist jedoch aufgrund limitierter raeumlicher Aufloesung begrenzt. Die Radioembolisation von mit {sup 90}Yttrium beladenen Mikrosphaeren (selektive interne Radiotherapie, SIRT) ermoeglicht eine wenig invasive Therapie primaerer und sekundaerer Lebertumoren. Zur Vermeidung von Nebenwirkungen der Mikrosphaeren durch einen Abstrom in Darm, Magen und Lunge muss vor Therapiebeginn eine Darstellung des durch die leberversorgenden Arterien versorgten Gebiets mittels {sup 99m}Tc-MAA ({sup 99m}Technetium-makroaggregiertes Albumin) und einer Szintigraphie erfolgen. Auch hier limitiert die begrenzte morphologische Information der Szintigraphie das Therapiemonitoring. {sup 131}Jod-Ganzkoerperszintigramm zum Nachweis einer erfolgreichen Ablation und Staging ca. 3-4 Tage postablativ bei Patienten mit DTC. Ueberwachung des

  4. 99mTc-ECD brain perfusion SPECT in hyperalgesic fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Mundler, Olivier; Niboyet, Jean

    2007-01-01

    Neuro-imaging studies with 99m Tc-HMPAO SPECT in fibromyalgia (FM) patients have reported only limited subcortical hypoperfusion. 99m Tc-ECD SPECT is known to provide better evaluation of areas of high cerebral blood flow and regional metabolic rate. We evaluated a homogeneous group of hyperalgesic patients with FM using 99m Tc-ECD SPECT. The aim of this study was to investigate brain processing associated with spontaneous pain in FM patients. Eighteen hyperalgesic FM women (mean age 49 years, range 25-63 years; American College of Rheumatology criteria) and ten healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). Visual Analogue Scale score for pain was 82±4 at the time of the SPECT study. Compared with control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis, with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. In the present study, performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in the sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective-attentional dimension. As current pharmacological and non-pharmacological therapies act differently on the two components of pain, we hypothesise that SPECT could be a valuable and readily available tool to guide individual therapeutic strategy and provide objective follow-up of pain processing recovery under treatment. (orig.)

  5. Multimodality imaging: transfer and fusion of SPECT and MRI data

    International Nuclear Information System (INIS)

    Knesaurek, K.

    1994-01-01

    Image fusion is a technique which offers the best of both worlds. It unites the two basic types of medical images: functional body images(PET or SPECT scans), which provide physiological information, and structural images (CT or MRI), which provide an anatomic map of the body. Control-point based registration technique was developed and used. Tc-99m point sources were used as external markers in SPECT studies while, for MRI and CT imaging only anatomic landmarks were used as a control points. The MRI images were acquired on GE Signa 1.2 system and CT data on a GE 9800 scanner. SPECT studies were performed 1h after intravenous injection of the 740 MBq of the Tc-99m-HMPAO on the triple-headed TRIONIX gamma camera. B-spline and bilinear interpolation were used for the rotation, scaling and translation of the images. In the process of creation of a single composite image, in order to retain information from the individual images, MRI (or CT) image was scaled to one color range and a SPECT image to another. In some situations the MRI image was kept black-and-white while the SPECT image was pasted on top of it in 'opaque' mode. Most errors which propagate through the matching process are due to sample size, imperfection of the acquisition system, noise and interpolations used. Accuracy of the registration was investigated by SPECT-CT study performed on a phantom study. The results has shown that accuracy of the matching process is better, or at worse, equal to 2 mm. (author)

  6. Brain SPECT in psychiatry: Delusion or reality?

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Epstein, P.; Kohn, R.; Antonino, F.; Devore-Best, S.; Craita, I.; Liu, P.

    2002-01-01

    Aim: The need for functional information is becoming increasingly evident for proper therapeutic approaches to the treatment and follow up of psychiatric diseases. While data on this subject already exists, there is a general lack of consensus about the use of brain SPECT in this domain and also a considerable negative prejudice due to a number of factors including poor quality imaging and unrealistic expectations. Based on a large group of brain SPECT-s performed over the past 3 years we attempted to sort and refine the indications for SPECT in psychiatry. Materials and Methods: High resolution brain SPECT was performed with triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A comprehensive semiquantitative color, 3D surface as well as multi-thresholded volume display was routinely used and supplemented by automatic realignment in case of longitudinal follow-up. Results: 470 brain SPECT-s done on 432 patients were all referred by psychiatrists or neuro-psychiatrists for a wide spectrum of psychiatric diseases and ranged in age from 7 to 88 years. The most common primary reasons for referral were : attention deficit hyperactive disorder (ADHD); anxiety; obsessive-compulsive disease, depression (refractory, chronic, bipolar ), impulse control problems; oppositional defiance, post traumatic brain injury; seizures, learning difficulties, pervasive development disorders, memory loss and differential of dementia. Among common denominators were long duration of the disease, unresponsiveness to treatment, worsening of clinical status, and presence of multiple conditions at the same time. The multiparametric display used enabled a comprehensive evaluation of the brain volume which included the hemispheric surfaces; the basal ganglia (striatum) and the thalamus, several components of the limbic and paralimbic systems: anterior and posterior cingulate and their respective subdivisions, insula-s and their subdivisions, apical and mesial

  7. Correlation with neuropsychological assessment and SPM analysis of brain perfusion SPECT in patients with progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Kang, Do Young; Park, Kyung Won; Kim, Jae Woo

    2004-01-01

    Progressive supranuclear palsy (PSP) is a degenerative condition of unknown aetiology that produces an akinetic-rigid form of parkinsonism characterised by early falls, dementia and abnormalities of extraocular movements. The patterns of decreased regional cerebral blood flow and cognitive impairment in PSP compared with normal control have been insufficiently investigated and a limited number of studies have been performed. We evaluated clinical symptoms, functional neuroimaging study using Tc-99m HMPAO SPECT and neuropsychological profiles in patients with PSP. Eleven patients with PSP diagnosed by the clinical criteria of National Institute of Neurological Disorders and Stroke and the Society for PSP (NINDS-SPSP) (mean age: 70.5±5.6 years, educational period: 4.5±4.7 years) and age-matched 10 healthy control subjects (mean age: 68.1±4.5 years, educational period: 6.5±4.1 years) participated in this study were participated. All patients were given a neurologic examination, brain MRI and cerebral perfusion SPECT using Tc-99m HMPAO. We concomittently evaluated several cognitive profiles using the Seoul Neuropsychological Screening Battery. SPM analysis of the SPECT image showed significant perfusion deficits in the left inferior frontal gyrus, left caudate nucleus, left middle frontal gyrus and cingulate gyrus in the patients with PSP compared with age-matched healthy control (uncorrected p<0.01). On neuropsychological assessment, cognitive deficits on verbal and visual memory, word fluency and frontal executive functions were prominent in most patients with PSP compared with healthy control subjects. Our findings suggest that measurement of regional cerebral blood flow by perfusion SPECT and voxel-based SPM analysis with neuropsychological assessment are useful to understanding the correlation between perfusion deficits and abnormal cognitive profiles in patients with PSP

  8. Correlation with neuropsychological assessment and SPM analysis of brain perfusion SPECT in patients with progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Young Jin; Kang, Do Young; Park, Kyung Won; Kim, Jae Woo [School of Medicine, Dong-A University, Busan (Korea, Republic of)

    2004-07-01

    Progressive supranuclear palsy (PSP) is a degenerative condition of unknown aetiology that produces an akinetic-rigid form of parkinsonism characterised by early falls, dementia and abnormalities of extraocular movements. The patterns of decreased regional cerebral blood flow and cognitive impairment in PSP compared with normal control have been insufficiently investigated and a limited number of studies have been performed. We evaluated clinical symptoms, functional neuroimaging study using Tc-99m HMPAO SPECT and neuropsychological profiles in patients with PSP. Eleven patients with PSP diagnosed by the clinical criteria of National Institute of Neurological Disorders and Stroke and the Society for PSP (NINDS-SPSP) (mean age: 70.5{+-}5.6 years, educational period: 4.5{+-}4.7 years) and age-matched 10 healthy control subjects (mean age: 68.1{+-}4.5 years, educational period: 6.5{+-}4.1 years) participated in this study were participated. All patients were given a neurologic examination, brain MRI and cerebral perfusion SPECT using Tc-99m HMPAO. We concomittently evaluated several cognitive profiles using the Seoul Neuropsychological Screening Battery. SPM analysis of the SPECT image showed significant perfusion deficits in the left inferior frontal gyrus, left caudate nucleus, left middle frontal gyrus and cingulate gyrus in the patients with PSP compared with age-matched healthy control (uncorrected p<0.01). On neuropsychological assessment, cognitive deficits on verbal and visual memory, word fluency and frontal executive functions were prominent in most patients with PSP compared with healthy control subjects. Our findings suggest that measurement of regional cerebral blood flow by perfusion SPECT and voxel-based SPM analysis with neuropsychological assessment are useful to understanding the correlation between perfusion deficits and abnormal cognitive profiles in patients with PSP.

  9. Ictal and interictal SPECT imaging of 8 patients with symptomatic partial epilepsy

    International Nuclear Information System (INIS)

    Motooka, Hiromichi

    1993-01-01

    Although epileptic discharges such as spike, spike and wave complex, sharp wave, and sharp and wave complex can be recorded by interictal scalp electroencephalography (EEG) in many patients with epilepsy, recent studies have demonstrated that no epileptic discharges can be recorded by interictal and ictal scalp EEGs in some patients who clinically exhibit epileptic seizures. Accordingly scalp EEG is not always helpful for diagnosing epilepsy or identifying the epileptic foci in the brain in these patients. Recently, studies using single photon emission computed tomography (SPECT) have been performed for patients with epilepsy and evidence that epileptic foci can be identified by changes in the regional cerebral blood flow (rCBF) seen on SPECT scanning have been accumulated. In the present study, therefore, 8 patients with medically intractable partial seizures were simultaneously or independently investigated by the recordings of scalp EEG and SPECT scanning during the interictal and ictal period. N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) was used for SPECT scanning for 7 patients and 99m Tc-d,l-hexamethyl-propyleneamineoxime ( 99m Tc-HMPAO) for 1 patient. An increase in rCBF (hyperperfusion) or decrease in rCBF (hypoperfusion) were found in 4 patients by interictal SPECT imaging and in all patients by ictal SPECT imaging although epileptic discharges were observed in 3 patients by interictal scalp EEG and 5 patients by ictal scalp EEG. The findings of the present study indicate that ictal SPECT scanning is more useful for diagnosing epilepsy and identifying the epileptic foci in the brain than ictal scalp EEG. (author)

  10. Diagnosis of leg osseous infection in diabetics: place of scintigraphy of the polynuclear hydrocarbons labelled by HMPAO-{sup 99m}Tc (HMPAO-LS); Diagnostic de l`infection osseuse du pied chez le diabetique: place de la scintigraphie aux polynucleaires marques a l`HMPAO-Tc 99m (HMPAO-LS)

    Energy Technology Data Exchange (ETDEWEB)

    Devillers, A.; Moisan, A.; Hennion, F.; Poirier, J.Y.; Bourguet, P. [CRLCC Eugene Marquis, Medecine Nucleaire, CHRU Endocrinologie, Rennes (France)

    1997-12-31

    In case of leg infection in diabetics it is difficult to differentiate between a chronic osteopathy, an infection of the soft tissues and an osteomyelitis (OM). We considered of interest to evaluate by a HMPAO-LS prospective study the diagnosis of osteitis in diabetic legs. Twenty seven diabetic (DID type 1 = 11, DNID type 2 = 16) patients (19 M and 8 F, average age 64 years), clinically suspected with a leg osteo-articular infection (malum perforans or cellulitis, uni- or bi-lateral, unique or multiple lesions) were included in the study. For all of them a standard radiographic examination centered on the legs, a (3 phases) osseous scintigraphy and a HMPAO-LS were achieved over 3 days. The HMPAO-LS was considered as in favour of a OM when there was an abnormal accumulation of granulocytes concordant with a hyper-fixation by osseous scintigraphy. In case of 37 retained lesions 20 OM were proved: - 8 sites, on radiological arguments and histological and/or microbiological criteria after osseous biopsy; - 8, by the radiological examination only; - 4, on biopsy arguments, only. Seventeen lesions were not OM, of which 7 were cellulitis. The sensitivity of the HMPAO-LS was 90% with a specificity of 94%. 8/20 OM had initial normal radiographs confirming the precocity of OM diagnosis by HMPAO-LS. Twelve HMPAO-LS were effected in OM evolutive surveillance. All of them became negative on the control initial site of the healing of OM. In conclusion, the HMPAO-LS appears to be an alternative to choose in the diagnosis and in the evolution surveillance of leg OM in diabetics, particularly when the healing of the perforans softs is incomplete and the question of the osteitis healing or sequel of an anti-biotherapy is posed

  11. Regional cerebral blood flow in SPECT pattern in Parkinson's disease

    International Nuclear Information System (INIS)

    Lenart-Jankowska, D.; Junik, R.; Sowinski, J.; Gembicki, M.; Wender, M.

    1997-01-01

    The purpose of our work was to compare the regional cerebral blood flow (rCBF) in SPECT examination in Parkinson's disease with (17 cases) and without (7 cases) dementia and in various clinical stages of the disease. The patients underwent SPECT examination 5-40 min after intravenous application of HMPAO (Ceretec, Amersham) with 740 Mbq (20 mCi) pertechnate 99m Tc. SPECT was performed with a Siemens Diacam single-head rotating gamma camera coupled to a high resolution collimator and Icon computer system provided by the manufacturer. The results were defined in relative values of ROI in relation to cerebellum. Patients with Parkinson's disease showed hypoperfusion in cerebral lobes and in deep cerebral structures including the basal ganglia. Regional perfusion deficit in SPECT was seen with and without associated dementia and already in early stage of the disease. Parkinson's disease is provoked by the lesions of dopaminergic neurons of the central nervous system leading to domination of extrapyramidal symptoms. There are many indications that also the neurotransmitters associated with cognitive functions as acetylcholine demonstrate some abnormalities. However, only in some cases of Parkinson's disease dementia is the dominating symptom. Our results of regional cerebral blood flow testify that in Parkinson's disease the dysfunction of the central nervous system is more diffuse than has previously been suggested. (author)

  12. Diagnosis of leg osseous infection in diabetics: place of scintigraphy of the polynuclear hydrocarbons labelled by HMPAO-99mTc (HMPAO-LS)

    International Nuclear Information System (INIS)

    Devillers, A.; Moisan, A.; Hennion, F.; Poirier, J.Y.; Bourguet, P.

    1997-01-01

    In case of leg infection in diabetics it is difficult to differentiate between a chronic osteopathy, an infection of the soft tissues and an osteomyelitis (OM). We considered of interest to evaluate by a HMPAO-LS prospective study the diagnosis of osteitis in diabetic legs. Twenty seven diabetic (DID type 1 = 11, DNID type 2 = 16) patients (19 M and 8 F, average age 64 years), clinically suspected with a leg osteo-articular infection (malum perforans or cellulitis, uni- or bi-lateral, unique or multiple lesions) were included in the study. For all of them a standard radiographic examination centered on the legs, a (3 phases) osseous scintigraphy and a HMPAO-LS were achieved over 3 days. The HMPAO-LS was considered as in favour of a OM when there was an abnormal accumulation of granulocytes concordant with a hyper-fixation by osseous scintigraphy. In case of 37 retained lesions 20 OM were proved: - 8 sites, on radiological arguments and histological and/or microbiological criteria after osseous biopsy; - 8, by the radiological examination only; - 4, on biopsy arguments, only. Seventeen lesions were not OM, of which 7 were cellulitis. The sensitivity of the HMPAO-LS was 90% with a specificity of 94%. 8/20 OM had initial normal radiographs confirming the precocity of OM diagnosis by HMPAO-LS. Twelve HMPAO-LS were effected in OM evolutive surveillance. All of them became negative on the control initial site of the healing of OM. In conclusion, the HMPAO-LS appears to be an alternative to choose in the diagnosis and in the evolution surveillance of leg OM in diabetics, particularly when the healing of the perforans softs is incomplete and the question of the osteitis healing or sequel of an anti-biotherapy is posed

  13. MRI and brain spect findings in patients with unilateral temporal lobe epilepsy and normal CT scan

    Directory of Open Access Journals (Sweden)

    P.G. Carrilho

    1994-06-01

    Full Text Available 26 patients with temporal lobe epilepsy clinically documented by several abnormal interictal surface EEGs with typical unitemporal epileptiform activity and a normal CT scan were studied. Interictal99mTC HMPAO brain SPECT and MRI were performed in all subjects. Abnormalities were shown in 61.5% of MRI (n=16 and 65.4% of SPECT (n=17. Hippocampal atrophy associated to a high signal on T2-weighted MRI slices suggesting mesial temporal sclerosis was the main finding (n=12; 75% of abnormal MRI. MRI correlated well to surface EEG in 50% (n=13. There was also a good correlation between MRI and SPECT in 30.7% (n=8. SPECT and EEG were in agreement in 57.7% (n=l5. MRI, SPECT and EEG were congruent in 26.9% (n=7. These results support the usefulness of interictal brain SPECT and MRI in detecting lateralized abnormalities in temporal lobe epilepsy. On the other hand, in two cases, interictal SPECT correlated poorly with surface EEG. This functional method should not be used isolately in the detection of temporal lobe foci. MRI is more useful than CT as a neuroimaging technique in temporal lobe epilepsy. It may detect small structural lesions and mesial temporal lobe sclerosis which are not easily seen with traditional CT scanning.

  14. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru; Aburano, Tamio

    2000-01-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by 99m Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma was

  15. The development of 99mTc-d, 1-HM-PAO

    International Nuclear Information System (INIS)

    Bai Lanqin; Huang Jinjie; Fan Li; Bai Suzhen; Li Guoli; Jing Hui; Xiao Lun

    1991-12-01

    The 99m Tc-d,1-HM-PAO is an ideal radiopharmaceutical for regional cerebral blood perfusion imaging. The improvement of synthesis and separation of diastereoisomers leads to obtain high purity (>99%) of d, 1-HM-PAO and meso-HM-PAO. During separation H NMR spectroscopy was used to monitor the relative composition of these two diastereoisomers that can ensure the purity of pligand of d,1-HM-PAO. The intravenous injection of 99m Tc-d,1-HM-PAO was formed by adding fresh 99m Tc washing liquor into a sterile. Pyrogen-free and freeze-dried vial. The radiochemical purity (RCP) of 99m Tc-d,1-HM-PAO was greater than 80%. From the experiments of 99m Tc-d,1-HM-PAO in mice, after two minutes of intravenously (I>V>) administration about 2.24% of injected dose (I.D.)appeared in the brain, and after 24 hours about 72% of radioactivity of injected dose still left in the brain. But for the 99m Tc-meso-HM-PAO after two minutes of i.v. administration, about 1.93% of I.D. appeared in the brain, and 24 hours later, 25% of radioactivity of I.D. was in the brain. This result shows that in the brain the radioactivity of 99m Tc-meso-HM-PAO declines faster than that of 99m Td-d,1-HM-PAO

  16. The Performance of Ictal Brain SPECT Localizing for Epileptogenic Zone in Neocortical Epilepsy

    International Nuclear Information System (INIS)

    Kim, Eun Sik; Lee, Dong Soo; Hyun, In Young; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Lee, Sang Kun; Chang, Kee Hyun

    1995-01-01

    The epileptogenic zones should be localized precisely before surgical resection of these zones in intractable epilepsy. The localization is more difficult in patients with neocortical epilepsy than in patients with temporal lobe epilepsy. This study aimed at evaluation of the usefulness of ictal brain perfusion SPECT for the localization of epileptogenic zones in neocortical epilepsy. We compared the performance of ictal SPECT with MRI referring to ictal scalp electroencephalography (sEEG). Ictal 99m Tc-HMPAO SPECT were done in twenty-one patients. Ictal EEG were also obtained during video monitoring. MRI were reviewed. According to the ictal sEEG and semiology, 8 patients were frontal lobe epilepsy, 7 patients were lateral temporal lobe epilepsy, 2 patients were parietal lobe epilepsy, and 4 patients were occipital lobe epilepsy. Ictal SPECT showed hyperperfusion in 14 patients(67%) in the zones which were suspected to be epileptogenic according to ictal EEG and semiology. MRI found morphologic abnormalities in 9 patients(43%). Among the 12 patients, in whom no epileptogenic zones were revealed by MR1, ictal SPECT found zones of hyperperfusion concordant with ictal sEEG in 9 patients(75%). However, no zones of hyperperfusion were found in 4 among 9 patients who were found to have cerebromalacia, abnormal calcification and migration anomaly in MRI. We thought that ictal SPECT was useful for localization of epileptogenic zones in neocortical epilepsy and especially in patients with negative findings in MRI.

  17. Cranial MR imaging and cerebral 99mTc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    International Nuclear Information System (INIS)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-01-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and 99m Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOX) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS = III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (au) (18 refs.)

  18. Cranial MR imaging and cerebral 99mTc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    International Nuclear Information System (INIS)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-01-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and 99m Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOS) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS=III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (orig.)

  19. Brain spect in the pre-surgical evaluation of epileptic patients preliminary results

    Directory of Open Access Journals (Sweden)

    Carlos A. Buchpiguel

    1992-03-01

    Full Text Available Pre-surgical evaluation of epileptic patients consists of neurological examination, intensive electroencephalographic (EEG monitoring and anatomical studies (CT and MRI. Functional methods such as PET and SPECT imaging are now used more frequently. We have studied pre-operatively 15 adult epileptic patients (8 female, 7 male using a rotational scintillation camera interfaced to a dedicated computer. The tomographic images were obtained 15 minutes after intravenous injection of 99mTc_HMPAO. All had MRI scanning and intensive EEG monitoring which generally included seizure recording. Five patients had progressive lesions (3 meningiomas, 2 astrocytomas. In 10 patients, neuroradiological studies did not show the presence of progressive lesions (2 normal scans and 8 cases with inactive lesions. Two patients with meningioma showed hypoperfusion at the lesion site while the third patient had a marked hyperperfusion which might correlate with the clinical diagnosis of epilepsia partialis continua. In the astrocytoma patients SPECT scans showed hypoperfusion at the lesion site. Data obtained from the 10 patients without progressive CNS lesions showed: (a in 4, SPECT findings correlated well with the anatomical findings; (b in 5 instances, SPECT was able to disclose additional functional deficits; (c in one case, there was no SPECT correlate of a discrete anatomical lesion. In 5 of these cases with no progressive lesions (n=10 SPECT findings were useful as a complementary tool in determining the clinical or surgical management of these patients. Despite the small number and hete-rogenicity of the present sample, SPECT seems to be an useful tool as part of the clinical workup of epileptic patients who are candidates for epilepsy surgery.

  20. Brain SPECT of chronic fatigue syndrome (CFS): a blinded visual analysis

    International Nuclear Information System (INIS)

    Casse, R.; Chew, G.; Barnden, L.; DelFante, P.; Burnet, R.; Kwiatek, R.; Chew, J.; Behin-Ain, S.; Unger, S.

    2002-01-01

    Full text: Chronic fatigue syndrome (CFS) is a debilitating and complex disorder characterised by profound fatigue and neuropsychiatric dysfunction. Previous studies with cerebral perfusion SPECT (rCBF) scans have yielded conflicting results. Most were performed with inhomogeneous patient populations and the findings were not based on a blinded visual analysis. To address this, HMPAO SPECT on a triple head gamma camera was performed on a group of 59 subjects. This group included 32 subjects (16-61 years, 24F and 8M) with moderate CFS based on the Fukuda criteria not on medication and not depressed and 27 normal volunteers (20-56 years, 16F and 11 M). Two blinded reviewers (RC and GC) separately assessed the SPECT studies. 28 brain structures were scored as either definitely abnormal(1), possibly abnormal(2) or normal(3-5). Abnormal results were only found in the temporal lobes and brainstem. The results (Sensitivity/Specificity) based on scores 1 or 2, show that that abnormal score yielded acceptable specificity but low sensitivity. Scores 1 or 2 improved sensitivity but reduced the specificity. This shows that visual analysis of brain SPECT is not a reliable discriminant test for CFS, although quantitative analysis with statistical parametric mapping (SPM) has demonstrated significant abnormalities. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  1. Cerebral SPECT, a new diagnostic marker in depression

    International Nuclear Information System (INIS)

    Galli, Enrique

    2001-01-01

    Over the past twenty years the functional brain imagenology has improved greatly. Today the diagnostic, prognostic and therapeutic response are possible in psychiatry and neurology. The functional denomination in psychiatry has been known for more than a 100 years and it can be evident in the brain images. The relation between the blood brain flux and the brain can be seen as pictures in the Brain SPECT as hyper and hypo function areas. To carry out SPECT a venous injection of Tc-99m Technetium and (HMPAO) or (ECD) is applied in the arm. The images correspond to a period of two minutes after injection. The exam can be done until six hours after the brain fixation. The study is carried out in conditions, with the patient in repose, relaxed and without medication. The final result is an brain in colors. The yellow color gives us 95% of decrease and white color 95% of increase of the brain function. The red color gives a normal perfusion. The object of the study is to find that the Brain SPECT could be used as a new diagnostic marker of depression. The sample was 73 outpatients with major depression Our diagnostic marker is the prefrontal cortex ventral hypoperfusion (orbit frontal) in almost 100% of the patients and only 32% dorsal hypoperfusion (executive area), unlike most authors (Au)

  2. Cranial MR imaging and cerebral [sup 99m]Tc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-11-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and [sup 99m]Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOX) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS = III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (au) (18 refs.).

  3. {sup 99m}Tc-ECD brain perfusion SPECT in hyperalgesic fibromyalgia

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Mundler, Olivier [Assistance Publique des Hopitaux de Marseille, Centre Hospitalo-Universitaire de la Timone, Service Central de Biophysique et de Medecine Nucleaire, Marseille Cedex 05 (France); Niboyet, Jean [Clinique La Phoceanne, Unite d' Etude et de Traitement de la Douleur, Marseille (France)

    2007-01-15

    Neuro-imaging studies with {sup 99m}Tc-HMPAO SPECT in fibromyalgia (FM) patients have reported only limited subcortical hypoperfusion. {sup 99m}Tc-ECD SPECT is known to provide better evaluation of areas of high cerebral blood flow and regional metabolic rate. We evaluated a homogeneous group of hyperalgesic patients with FM using {sup 99m}Tc-ECD SPECT. The aim of this study was to investigate brain processing associated with spontaneous pain in FM patients. Eighteen hyperalgesic FM women (mean age 49 years, range 25-63 years; American College of Rheumatology criteria) and ten healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). Visual Analogue Scale score for pain was 82{+-}4 at the time of the SPECT study. Compared with control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis, with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. In the present study, performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in the sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective-attentional dimension. As current pharmacological and non-pharmacological therapies act differently on the two components of pain, we hypothesise that SPECT could be a valuable and readily available tool to guide individual therapeutic strategy and provide objective follow-up of pain processing recovery under treatment. (orig.)

  4. Thrombocytopenic thrombotic purpura: severe clinic with no CT, minor MRI, but a SPECT correlate

    Energy Technology Data Exchange (ETDEWEB)

    Baron, Y. [Radiologische Abteilung, Staedtisches Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Bargemann, T. [Abteilung Internistische Intensivmedizin und Dialyse am Staedtischen Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Harten, P. [Zweite Medizinische Universitaetsklinik und Poliklinik der Christian-Albrechts-Universitaet zu Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Gutschmidt, H.-J. [Abteilung Internistische Intensivmedizin und Dialyse am Staedtischen Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany)

    1999-07-01

    A 28-year-old woman with primarily therapy refractory TTP was followed neuroradiologically over 6 months. Despite pronounced neurological and neuropsychiatric symptoms including hemiparesis and aphasia she had unremarkable CT scans on two occasions. Three MRI exams showed no correlate for her neurological symptoms except a small petechial cortical hemorrhage in the right parietooccipital gyrus which may account for her TTP-related anxiety disorder. A cerebral HMPAO-SPECT showed long-standing right-sided hypoperfusion compatible with residual vasculature changes. The possible causes for the clinico-neuroradiological discrepancies are discussed in view of the literature.

  5. Thrombocytopenic thrombotic purpura: severe clinic with no CT, minor MRI, but a SPECT correlate

    International Nuclear Information System (INIS)

    Baron, Y.; Bargemann, T.; Harten, P.; Gutschmidt, H.-J.

    1999-01-01

    A 28-year-old woman with primarily therapy refractory TTP was followed neuroradiologically over 6 months. Despite pronounced neurological and neuropsychiatric symptoms including hemiparesis and aphasia she had unremarkable CT scans on two occasions. Three MRI exams showed no correlate for her neurological symptoms except a small petechial cortical hemorrhage in the right parietooccipital gyrus which may account for her TTP-related anxiety disorder. A cerebral HMPAO-SPECT showed long-standing right-sided hypoperfusion compatible with residual vasculature changes. The possible causes for the clinico-neuroradiological discrepancies are discussed in view of the literature

  6. Quantitative analysis of d,1-HMPAO and its freeze-dried kit with HPLC

    International Nuclear Information System (INIS)

    Chen Suzhen

    1993-05-01

    A quantitative analysis method, which uses RP-HPLC (reversed phase-high performance liquid chromatography), has been established to determine the stereoisomeric purity of HMPAO and d,1-HMPAO content for d,l-HMPAO freeze-dried kit. An opitmal mobile phase is selected for obtaining chromatographic parameters that are better than those published in the references. The theoretical tray height is less than 0.06 mm. At the flowrate of 1 ml/min the total separation time is 5.5. The resolution is greater than 5. The detectable limits of meso-HMPAO and d,l-HMPAO are 1 x 10 -8 g and 5 x 10 -7 g respectively. The precision is 5% and the additional recovery is 94% ∼ 107%. This method has many advantages such as accuracy, simplicity, rapidity and stability, and it is suitable for routine inspection. It has been successfully used to determine the HMPAO stereoisomer and d,1-HMPAO of freeze-dried kit produced by China Institute of Atomic Energy and same products imported from Amersham Company of United Kingdom

  7. Interictal SPECT of rCBF is of clinical utility in the preoperative evaluation of patients with partial epilepsy

    DEFF Research Database (Denmark)

    Andersen, A R; Hansen, B A; Høgenhaven, H

    1996-01-01

    Fifty-eight patients with drug-resistant partial epilepsy were studied preoperatively by interictal rCBF measurements using 99mTc-HMPAO and a dedicated brain SPECT camera (Tomomatic 64). Follow-up of seizure outcome, using the "Engel score", was at least 3 years. The data were analyzed in a blinded...... set-up, first visually and subsequently quantitatively by an automatic regional analysis. By visual analysis 95% of the patients were considered abnormal in one part of the brain, of whom 27% were abnormal on CT, 45% on MRI and 98% on scalp EEG. Using a quantitative regional analysis subdividing each...... patients ictal SPECT of rCBF was additionally performed. In 2 cases it added further information to the patient evaluation....

  8. Interictal SPECT of rCBF is of clinical utility in the preoperative evaluation of patients with partial epilepsy

    DEFF Research Database (Denmark)

    Andersen, A.R.; Hansen, B.A.; Hogenhaven, H

    1996-01-01

    Fifty-eight patients with drug-resistant partial epilepsy were studied preoperatively by interictal rCBF measurements using 99mTc-HMPAO and a dedicated brain SPECT camera (Tomomatic 64). Follow-up of seizure outcome, using the 'Engel score', was at least 3 years. The data were analyzed in a blinded...... set-up, first visually and subsequently quantitatively by an automatic regional analysis. By visual analysis 95% of the patients were considered abnormal in one part of the brain, of whom 27% were abnormal on CT, 45% on MRI and 98% on scalp EEG. Using a quantitative regional analysis subdividing each...... patients ictal SPECT of rCBF was additionally performed. In 2 cases it added further information to the patient evaluation...

  9. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by {sup 99m}Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru [Kushiro Neurosurgical Hospital, Hokkaido (Japan); Aburano, Tamio

    2000-08-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by {sup 99m}Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma

  10. Investigation into the mechanisms of vagus nerve stimulation for the treatment of intractable epilepsy, using {sup 99m}Tc-HMPAO SPET brain images

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, Anna; Chisholm, Jennifer A.; Patterson, James; Wyper, David [Department of Clinical Physics, Institute of Neurological Sciences, Southern General Hospital, 1345 Govan Road, Glasgow G51 4TF (United Kingdom); Duncan, Roderick [Department of Neurology, Institute of Neurological Sciences, Southern General Hospital, Glasgow (United Kingdom); Lindsay, Kenneth [Department of Neurosurgery, Institute of Neurological Sciences, Southern General Hospital, Glasgow (United Kingdom)

    2003-02-01

    Vagus nerve stimulation (VNS) has gained recognition as a treatment for refractory epilepsies where surgical treatment is not possible. While it appears that this treatment is effective in some patients, the mechanism of action is not clearly understood. The purpose of this study was to clarify findings of other positron emission tomography and single-photon emission tomography (SPET) investigations by measuring the acute effect of VNS on patients who have normal cerebral anatomy on magnetic resonance imaging and who have not previously been exposed to VNS. We investigated six subjects (two males and four females, mean age 29.5 years, range 21-39 years) with intractable epilepsy. One patient had primary generalised epilepsy causing generalised tonic-clonic seizures; the remaining five patients had localisation-related epilepsy causing complex partial seizures. SPET imaging was performed using 250 MBq of {sup 99m}Tc-HMPAO and a four-scan paradigm - two with and two without stimulation. The stimulation began at VNS current levels of 0.25 mA and was increased according to the limit of patients' tolerance, usually defined by coughing or discomfort. The stimulating waveform was of continuous square wave pulses of 500 {mu}s duration at 30 Hz. Image analysis was by SPM99. Reduced perfusion during stimulation was observed in the ipsilateral brain stem, cingulate, amygdala and hippocampus and contralateral thalamus and cingulate. The study provides further evidence of the involvement of the limbic system in the action of vagal nerve stimulation. (orig.)

  11. Sensitivity of technetium-99m-d,1-HMPAO to radiolysis in aqueous solutions

    International Nuclear Information System (INIS)

    Tubergen, K.; Corlija, M.; Volkert, W.A.; Holmes, R.A.

    1991-01-01

    The sensitivity of technetium-99m- (99mTc) d,l-HMPAO to radiolytically induced dissociation in aqueous solutions was investigated. It was found that cobalt-60 (60Co) gamma irradiation of solutions containing 99mTc-d,l-HMPAO with only 1600 cGy reduced the lipophilic chelates' radiochemical purity (RCP) to 50%-60%. The radiolytic sensitivity of 99mTc-meso-HMPAO is significantly lower. The results indicate that radiolytically produced intermediates limit the in vitro stability of 99mTc-d,l-HMPAO

  12. Advances in regional cerebral blood flow measurement and patho-physiological analysis by SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo [Niigata Univ. (Japan). School of Medicine

    1994-04-01

    Recently, two kinds of radiopharmaceuticals have been developed to represent the biodistribution of regional blood flow, which are N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and [sup 99m]Tc-hexamethylpropylene-amine-oxime (HMPAO). The charachteristics, clinical usage and imitation of these two radiolabeled agents are discussed. The advantage of [sup 123]I-IMP is that it has high first-pass extraction and long retention in brain tissue, hence it can be used to measure the absolute values of regional cerebral blood flow (rCBF). When the kinetics of [sup 123]I-IMP is assumed to be freely diffusible in the brain, its behavior is considered by 2-compartment model, especially which is assumed by the microsphere model in the early period after the i.v. injection of [sup 123]I-IMP. Comparing the rCBF measured by [sup 123]I-IMP with that by [sup 133]Xe inhalation SPECT method, we have to consider PaCO[sub 2] when both SPECT studies are performed, because PaCO[sub 2] is one of the big factors which make effects on the alteration of rCBF. [sup 123]I-IMP has an interesting character of the redistribution phenomenon which represrent the degree of ischemia in the cerebrovascular diseases. Distribution volume an important datum obtained by the SPECT study with [sup 123]I-IMP, which represent the degree of retention, i.e. binding potential of [sup 123]I-IMP in the brain tissue. I introduced the usage of the distribution volume of [sup 123]I-IMP, which was constructed in the rate constant square method, in the differential diagnosis of Parkinson's disease and progressive supranuclear palsy (PSP). The clinical usage of [sup 99m] Tc-HMPAT was mentioned, the advantage of which is the rapid fixation in the brain tissue and the distribution does not change for long time after the i.v. injection. Hence [sup 99m]Tc-HMPAO is used for the diagnosis of epileptic foci and certain loading tests such as balloon occlusion test, postural test and acetazolamide loading test. (author).

  13. Clinical study of cerebral blood flow in unilateral chronic subdural hematoma measured by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru; Aburano, Tamio

    2000-01-01

    Cerebral blood flow (CBF) measured by 99m Tc-HMPAO SPECT before operation was studied in 60 patients with unilateral chronic subdural hematoma. The regional CBF was measured in 26 regions of the fronto-occipital 10 cortices, putamen, thalamus and cerebellar hemisphere on both sides. Sixty cases with unilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms: 17 cases with headache (headache group), 34 cases with hemiparesis (hemiparesis group) and 9 cases with consciousness disturbance or dementia (consciousness disturbance group), and into three groups on the basis of the degree of midline brain shift on MRI: 7 cases of mild shift group, 24 cases of moderate shift group and 29 cases of severe shift group. The average CBF in 60 patients in each region indicated that the regional CBF was reduced in frontal, occipital cortices and cerebellum on the non-hematoma side, and in putamen and thalamus on the hematoma side. In the headache group, the regional CBF reduction on the non-hematoma side was found in only frontal and occipital cortices compared with the corresponding regions on the hematoma side. In the hemiparesis group, the regional CBF was reduced in frontal and occipital cortices on the non-hematoma side and in putamen and thalamus on the hematoma side. The part of CBF reduction in both hemispheres was also noted in the hemiparesis group. In the consciousness disturbance group, the CBF reduction was markedly noted in whole brain. The CBF reductions in frontal and occipital cortices on the non-hematoma side and in putamen, thalamus and cerebellum on the hematoma side was not mutually related with the degree of midline brain shift. We concluded that the disturbance of CBF in chronic subdural hematoma was started from frontal and occipital cortices on the non-hematoma side observed in the headache group, and which was extended to putamen and thalamus on the hematoma side and a part of both hemispheres observed in the

  14. NeuroSPECT assessment of ischemic penumbra in acute brain infarct: control of intra-arterial thrombolysis

    International Nuclear Information System (INIS)

    Mena, F.J.; Mena, I.; Contreras, I.; Soto, F.; Ducci, H.; Fruns, M.

    2002-01-01

    Introduction: Brain infarct is the most common cause of incapacity in adults, the second cause of dementia and the 2nd or 3rd cause of death. Acute brain infarct is a medical emergency potentially reversible if treated with thrombolysis in the first hours of evolution. Thrombolysis is now an approved and efficacious method of treatment for acute ischemic stroke. During the first 3 hours of evolution, intravenous administration of plasminogen activator (tPA) can be performed. The window of time of treatment is expanded to 6 hours with the intra-arterial super selective route for thrombolysis. Aim: The aim of this study was to define levels of reversible ischemia (penumbra) demonstrated by statistically evaluated HMPAO Tc99m NeuroSPECT performed before and after intra-arterial thrombolysis in the treatment of acute infarct. Materials and Methods: 21 patients were treated during the first 6 hours of evolution of an acute ischemic stroke with the following protocol. 1) Admission, and complete neurological evaluation. 2) Brain CT scan to rule hemorrhage or established infarct. 3) I.V injection of 1100MBq Tc99m HMPAO (Ceretec tm) 4) Conventional cerebral angiography and intra-arterial thrombolysis and/or angioplasty/stenting if necessary. 5) NeuroSPECT assessment of ischemic penumbra. 6) Control at 24 hrs with NeuroSPECT. NeuroSPECT image acquisition is performed immediately following arterial thrombolysis with a dual Head Camera, SHR collimators and conventional protocol. Image processing was performed using the Segami Software, as previously reported in Alasbimn Journal2 (7): April 2000. http://www.alasbimnjournal.cl. The analysis consists of 1) Tallairach brain volume normalization. 2) Voxel by voxel comparison of the individual brain cortex uptake normalized to the maximum in the cortex with a normal database of 24 age-matched controls. Results: The results are expressed in standard deviations (S.D.) below the normal mean. Normal mean is 72% + 6. Only voxels between

  15. Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

    International Nuclear Information System (INIS)

    Negus, Ian S.; Holmes, Robin B.; Thorne, Gareth C.; Saunders, Margaret; Jordan, Kirsty C.; Nash, David A.

    2016-01-01

    Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding 99m Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for

  16. Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

    Energy Technology Data Exchange (ETDEWEB)

    Negus, Ian S.; Holmes, Robin B.; Thorne, Gareth C.; Saunders, Margaret [Department of Medical Physics and Bioengineering, University Hospitals Bristol NHS Foundation Trust, Bristol BS28HW (United Kingdom); Jordan, Kirsty C. [Department of Biomedical Engineering, University of Strathclyde, Glasgow G11XQ (United Kingdom); Nash, David A. [Department of Medical Physics, Portsmouth Hospitals NHS Trust, Portsmouth PO63LY (United Kingdom)

    2016-09-15

    Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable

  17. Interictal rCBF SPECT, MRI and Surgical Outcome of Intractable Temporal Lobe Epilepsy

    International Nuclear Information System (INIS)

    Zeon, Seok Kil; Joo, Yang Goo; Lee, Sang Doe; Son, Eun Ik; Lee, Young Hwan

    1994-01-01

    Interictal single photon emission computed tomography of regional cerebral blood flow (rCBF SPECT) in 18 intractable temporal lobe epilepsy patients (8 male and 10 female patients: average 23.5 years old) were compared with 2.0 T magnetic resonance imaging (MRI). And surgical outcome was analysed with the findings, symptom duration and lateralization of temporal lobe. Preoperatively rCRF SPECT was done in all 18 patients with intravenous injection of 740 MRq 99 m T c-HMPAO. MRI was also done preoperatively in 13 patients. Surgical outcome was classified by Engel's outcome classification (four part classification recommended at the first Palm Desert conference). rCRF SPECT detected correctly lateralising abnormality of temporal lobe hypoperfusion in 13/ 18 (72.2%), contralateral temporal lobe hypoperfusion in 2/18 (11.1%) and showed no definite abnormality in 3/18 (16.7%). The positive predictive value of unilateral temporal lobe hypoperfusion was 87%. MRI detected correct localising abnormality in 8/13 (61.5%), such as hippocampal atrophy (7/13), asymmetric temporal horn (6/13), anterior temporal lobe atrophy (1/13), increased signal intensity from hippocampus (1/13) and calcific density (1/13), and no abnormal finding was noted in 5/13 (38.5%), There was no false positive findings and the positive predictive value of MRI was 100%, Only 2 cases showed same lateralization findings in rCBF SPECT and MRI. There was no significant correlation between symptom duration and no abnormal findings on SPECT or MRI. Surgical outcome showed class I in 15/18 (83.3%), and class II in 2/18 (11.1%). One case of no abnormal finding in both SPECT and MRI showed class III surgical outcome. No class IV surgical out.come was noted. Surgical outcome, lateralization of epileptic focus in temporal lobe and abnormal findings in rCBR SPECT or MRI were not significantly correlated.

  18. Validation of a cartridge method for the quality control determination of 99Tcm-HMPAO

    International Nuclear Information System (INIS)

    Pandos, G.; Penglis, S.; Tsopelas, C.; Royal Adelaide Hospital, Adelaide, SA

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of ±-HMPAO requires the use of three solvent types on two different stationary phases, and is time-consuming (∼ 15 min) in consideration of the short shelf-life (30 min). An impetus to develop a rapid quality control procedure for this product has led to the use of a single strip Whatman 17 chromatography system using ethyl acetate as the developing solvent. This popular Whatman paper system was previously validates against the manufacturer's method. We have developed a new method to successfully determine the % RCP of ±-HMPAO, which employs a disposable, inexpensive and reusable Amprep C-18 cartridge with normal saline as a non-organic mobile phase. The Whatman paper system separates the primary lipophilic 99 Tc m -HMPAO complex from 99 Tc m O-2, 99 Tc m O 4 and secondary 99 Tc m -HMPAO complex at the origin. By comparison, the lipophilic portion was retained on the cartridge and the hydrophilic impurities were found in saline eluent with the cartridge method. Whatman 17 paper system results showed 95.1 ± I.7% 99 Tc m -HMPAO after 5 min and the cartridge method gave 95.5 ± 1.5% 99 Tc m -HMPAO (n = 8) after 3 min. The % 99 Tc m O 2 levels in 99 Tc m -HMPAO were insignificant. When a failed kit was assessed for RCP at 2.5 h post-reconstitution, the Whatman paper system and the cartridge method correlated well, resulting in 63.1 ± 2.7% and 62.9±2.1% 99 Tc m -HMPAO (n=3) respectively. Although the cartridge method may slightly overestimate the % RCP of 99 Tc m -HMPAO, it was found to be simple, rapid and reliable for the quality control analysis of routine 99 Tc m -HMPAO preparations

  19. Importance of SPECT/CT for knee and hip joint prostheses; Stellenwert der SPECT/CT bei Knie- und Hueftgelenkprothesen

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, K.; Steurer-Dober, I.; Huellner, M.W.; Veit-Haibach, P.; Allgayer, B. [Luzerner Kantonsspital (Switzerland). Institut fuer Nuklearmedizin und Roentgendiagnostik

    2012-07-15

    Complications, such as loosening or infections are common problems after hip or knee arthroplasty. If conventional X-rays are equivocal bone scintigraphy is the classical second-line imaging modality. Single photon emission computed tomography/computed tomography (SPECT/CT) offers metabolic and morphologic information in one imaging step and is becoming increasingly more available in larger hospitals. The SPECT/CT procedure is a promising method and is increasingly being used in daily routine to evaluate joint arthroplasty. The additional benefit compared with classical conventional bone scintigraphy has to be evaluated in further prospective studies. In our hospital SPECT/CT regularly gives important additional information regarding prosthetic joint complications. SPECT/CT is increasingly being used as the second step imaging standard modality if conventional X-rays are equivocal. (orig.) [German] Komplikationen wie Lockerung und Infekt stellen ein haeufiges Problem nach Hueft- und Kniegelenkprothesen dar. Wenn die konventionelle Roentgenaufnahme nicht zum Ziel fuehrt, ist die klassische konventionelle Skelettszintigraphie die am haeufigsten verwendete ''Second-line''-Bildgebung. Die ''single photon emission computed tomography''/CT (SPECT/CT) bietet metabolische und morphologische Informationen bzgl. Prothesenkomplikationen in einem Untersuchungsgang und ist zunehmend in groesseren Kliniken verfuegbar. Die SPECT/CT ist eine viel versprechende Methode und wird im klinischen Alltag bei der Evaluation von Gelenkprothesen zunehmend eingesetzt. Es sind noch mehr prospektive Studien noetig, um die Leistungsfaehigkeit und den Zusatznutzen gegenueber der klassischen Szintigraphie zu evaluieren. In unserer Klinik wird die Knochenszintigraphie bei der Abklaerung von Prothesenkomplikationen zumeist mit einer SPECT/CT kombiniert und liefert regelmaessig wichtige Zusatzinformationen. Die SPECT/CT entwickelt sich zunehmend zum Standard

  20. Anything wrong with brain SPECT? Not really

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Craita, I.; Liu, P.

    2002-01-01

    Aim: Despite increased evidence about the usefulness of Brain SPECT in Neuro-Psychiatry, it continues to represent only a low percentage of Nuclear Medicine procedures. The prevalent perception is that it is an inadequate diagnostic tool, and/or is not changing patient management. There are objective reasons for this, as the lack of awareness by Psychiatrists about the value of SPECT, but most important is the frequently poor quality of images provided. This can be due to inadequate gamma cameras but is mostly due to poor quality software. Materials and Methods: High resolution brain SPECT via triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A combination of commercial software and local optimization was used for the final displays as well as for realignment of sequential brain SPECT studies. Results: We found out that 6 basic software improvements are needed to generate a final display where features can be clearly distinguished and which can be also easily assimilated by the referring physician. 1) Color scales: simple and efficient tools needed to generate user friendly and semiquantitative color shades as needed. Unfortunately various color scales may be needed depending on printer and paper used. 2): 3 D displays allowing, multiple standardized thresholdings, any number of groupings, differential coloring (with functional meaning) and adequate labeling. Should be completely or at least mostly automatic. 3) Automatic realignment of sequential studies: such programs exist in various forms (free WWW versions, proprietary Beta versions, etc.) but are still not supplied by the gamma camera vendors for general use. Should provide SPECT -SPECT and SPECT MRI options. 4) Localization of structures and slices a) Triangulation of structures and b) Identification of section location. 5) Graphics improvement for generating any number of optimized summary displays to accompany reports. 6) Availability of voxel based quantification software

  1. Comparison of continuous with step and shoot acquisition in SPECT scanning

    International Nuclear Information System (INIS)

    McCarthy, L.; Cotterill, T.; Chu, J.M.G.

    1998-01-01

    Full text: Following the recent advent of continuous acquisition for performing SPECT scanning, it was decided to compare the commonly used Step and Shoot mode of acquisition with the new continuous acquisition mode. The aim of the study is to assess any difference in resolution from the resulting images acquired using the two modes of acquisition. Sequential series of studies were performed on a SPECT phantom using both modes of acquisition. Separate sets of data were collected for both high resolution parallel hole and ultra high resolution fan beam collimators. Clinical data was collected on patients undergoing routine gallium, 99m Tc-MDP bone and 99m Tc-HMPAO brain studies. Separate sequential acquisition in both modes were collected for each patient. The sequence of collection was also alternated. Reconstruction was performed utilising the same parameters for each acquisition. The reconstructed data were assessed visually by blinded observers to detect differences in resolution and image quality. No significant difference in the studies collected by either acquisition modes were detected. The time saved by continuous acquisition could be an advantage

  2. Assessment of personality disorder by means of NeuroSPECT

    International Nuclear Information System (INIS)

    Mena G, Ismael; Nader N, Armando; Valdes M, Cecilia; Riquelme V, Raul

    2012-01-01

    We report on functional imaging results in 24 patients of Personality Disorder (P.D.) performed with NeuroSPECT by means of Tc99m HMPAO, in Basal state and during frontal cortical activation by means of the Wisconsin Card Sorting Test. Results demonstrate that we can make the diagnosis of P.D. when we detect significant hypoperfusion (- 2 Stand/ Deviations below the normal mean for the same age group) in the subgenual area (Area 25 of Brodmann) and in Area 24 of Brodmann, the anterior cingulated gyrus. Both areas are paradoxically more hypoperfused during the Wisconsin Test. Among patients diagnosed with P.D. NeuroSPECT can distinguish between patients of Cluster B from the ones from Cluster C in both Basal and Activation State, while Cluster A from B could be differentiated only in Basal State. On the other hand Motor Impulsivity patients could be differentiated from the Cognitive group due to paradoxical hypoperfusion in motor areas 1,2,3, and 4 of Brodmann. While the number of patients studied appears reduced these results demonstrate the capability of diagnosing Personality Disorder and also the capability to improved understanding of the subgroups of this Disorder

  3. Contribution of the cerebral SPECT in the field of evaluation of the hemodynamic cerebral vascular accident risk in the Limb shaking syndrome; Apport de la TEMP cerebrale dans le cadre de l'evaluation du risque d'AVC hemodynamique dans le Limb Shaking Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lauer, V.; Wolff, V.; Marescaux, C. [CHU de Strasbourg, Unite neurovasculaire, service de neurologie, 67 (France); Namer, I.J. [CHU de Strasbourg, service de biophysique et medecine nucleaire, 67 -Strasbourg (France)

    2010-07-01

    The limb shaking syndrome (L.S.S.) is characterized by uncontrollable shaking of members that are caused by a passage in the upright or by an hyper extension of the neck and occur in a patient with internal carotid stenosis. To investigate the pathophysiology of L.S.S. we used brain SPECT (SPECT-E.C.D. or H.M.P.A.O.) to measure cerebral perfusion in the supine position and standing in three patients. (N.C.)

  4. Study on effects of an atypical antipsychotic, risperidone on regional cerebral blood flow with 99mTc-HMPAO SPECT in drug-naive and unmedicated schizophrenic patients

    International Nuclear Information System (INIS)

    Koiwa, Daisuke

    2003-01-01

    To examine the underlying mechanisms of intracerebral or clinical actions of the atypical antipsychotic, risperidone (RIS), the effects of RIS on absolute regional cerebral blood flows (rCBFs) measured with 99mTc-HMPAO SPECT and correlations between the rCBFs and psychotic symptoms assessed with positive and negative syndrome scale (PANSS) were investigated in 10 drug-naive and unmedicated schizophrenic patients with acute hallucinatory and delusional state. Both the SPECT and PANSS were repeated before and after oral 2-week administration of RIS 3 mg/day in all of the 10 patients and after subsequent 2-week administration of RIS 4-6 mg/day in half of the patients. The rCBF values were significantly decreased in the left precentral gyrus alone after the low dose of RIS 3 mg/day in comparison with before the RIS dose. The rCBF values were significantly decreased in the right cingulate, postcentral, inferior parietal gyri and the left inferior temporal gyrus after the high dose of RIS 4-6 mg/day in comparison with before the low dose of RIS 3 mg/day. The psychiatric assessment with PANSS showed an improvement of positive and negative symptoms after the low RIS dose and still more after the high RIS dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the low RIS dose showed a positive correlation between the rCBF values in the right middle temporal gyrus and hallucinations (mainly auditory hallucination). These results suggest that chronic RIS administration dose-dependently produces a decrease of rCBF in the cerebral cortex in the manner that the low dose decreases rCBF in a few restricted cortical regions, while the high dose induces the rCBF reduction in more widespread cortical regions. The RIS-induced rCBF decrease in the cerebral cortex is considered to be attributable to a secondary inactivation in the cerebral cortex due to D 2 dopamine receptor blockade of RIS in the striatum through the cortico

  5. SPECT with technetium-99m-HMPAO in relation to late cognitive outcome after surgery for ruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Saeveland, H.; Uski, T.; Brandt, L.; Sjoeholm, H.; Sonesson, B.

    1996-01-01

    Fifteen patients with a good neurological outcome after aneurysmal SAH and surgery were collected prospectively. Six months after surgery neurological examination and a SPECT study for evaluation of the three dimensional CBF distribution as well as an extensive neuropsychological test were performed. In all patients with pathological SPECT findings the location of the reduced regional CBF correlated with the location of the ruptured aneurysm and/or side of surgical approach. The volume of the brain tissue with reduced rCBF showed a great variety, from 9-112 cm 3 (mean: 33 cm 3 ). Similarly, the maximum flow reduction in the affected areas also varied considerably from 17-95 % (mean: 39 %). In general, the neuropsychological functioning of the patients post SAH was favourable. Seven individuals had a presumably normal neuropsychological appearance with respect to estimates of premorbid levels of functioning. Another four patients were slightly impaired and the remaining four were moderately affected. Only in five cases did the location of SPECT pathology and the site of neuropsychological impairment appear to coincide, whereas this was not the case in the remaining 10 patients. In general, the extent of SPECT pathology did not differ in the three neuropsychological outcome groups (normal, slight and moderate disability). (author)

  6. Comparison between CT perfusion and Tc-99m ECD SPECT in the assessment of cerebrovascular reserve: a case study

    International Nuclear Information System (INIS)

    Crouch, J.; Wood, C.; Campbell, A.; McCarthy, M.; Dunne, M.; Bynevelt, M.; Lenzo, N.

    2003-01-01

    Full text: Brain perfusion is sensitively assessed by cerebral SPECT imaging utilising perfusion agents such as Tc-99m HMPAO and Tc-99m ethyl cysteinate dimer (ECD). Positron emission tomography can accurately assess and quantify brain perfusion and MRI can also be used for perfusion assessment. Both MRI and PET however are currently limited by cost and availability. A new technique utilising CT with contrast has been developed to assess and quantitate cerebral perfusion. The technique utilises arterial input information and deconvolution analysis to develop quantifiable measures of perfusion and contrast transit. The technique has been validated for acute stroke assessment and is being assessed for other possible applications. We present a case study comparison of this technique with cerebral SPECT perfusion using Tc-99m ECD in the assessment of cerebrovasular reserve. In each case, the CT and SPECT studies were performed pre- and post-acetazolamide and the SPECT study was statistically compared with a normal database utilising an automated brain perfusion statistical analysis package (NeurostatT). We discuss the correlation found between techniques, their strengths, weaknesses and possible future roles. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Increased rCBF in gray matter heterotopias detected by SPECT using 99mTc hexamethyl-propylenamine oxime

    International Nuclear Information System (INIS)

    Henkes, H.; Klinikum Rudolf Virchow, Berlin; Hosten, N.; Cordes, M.; Neumann, K.; Hansen, M.L.

    1991-01-01

    Imaging findings of morphology and regional cerebral blood flow in two patients suffering from epileptic seizures are presented. CT and MRI revealed heterotopic gray matter as a probable structural correlate, causing the seizure disorder. 99m Tc hexamethyl-propylenamine oxime (HM-PAO) SPECT demonstrated focally increased regional cerebral blood flow in both patients in the areas of their heterotopic lesions. Heterotopic and orthotopic gray matter seem to have similar features in terms of regional perfusion. A focally increased brain perfusion in interictal epileptic patients may indicate an underlying migration anomaly. (orig.)

  8. Normal Control Study of Cerebral Blood Flow by 99mTc HM-PAO SPECT

    International Nuclear Information System (INIS)

    Koong, Sung Soo; Moon, Dae Hyuk; Lee, Bum Woo; Lee, Kyung Han

    1989-01-01

    Regional cerebral perfusion was evaluated in 15 normal controls by single photon emission computed tomography using 99m Tc HM-PAO. For quantitative analysis, 13 pairs of homologous region of interest (ROI) were drawn on three transverse slices matching the vascular territories and cerebral cortices, and normal values of 3 semiquantitative indices including 'Right to left ratio' (R/L ratio), 'Regional index' (RI), and 'Region to cerebellum ratio (R/cbll ratio) were calculated. Mean values of R/L ratios of homologous regions were ranged from 0.985 to 1.023, and mean ± 2 s.d. of all regions did not exceed 11% of mean. Significant difference of Rls (mean count per voxel of a ROI/mean count per voxel of total ROls) between regions were found (p<0.001) with highest values in occipital cortex and cerebellum. After attenuation correction, Rls in deep gray, cranial portion of anterior cerebral artery and vascular territories in the 2nd slice increased significantly (p<0.05-0.001) hut vise versa in other ROIs. Region to cerebellum ratios also showed regional difference similar to Rls.

  9. Serial studies of cerebral blood flow using 99Tcm-HMPAO

    DEFF Research Database (Denmark)

    Andersen, A R; Friberg, H; Lassen, N A

    1987-01-01

    -HMPAO was measured after i.v. injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6 to 10 mm (HR) and 15 to 20 (LR). 99Tcm-HMPAO images showed close resemblance to xenon-133 CBF tomograms. Only about 20% of the (decay corrected) brain counts were lost during...

  10. Impact of SPECT/CT in imaging inflammation and infection; Wertigkeit der SPECT/CT fuer die nuklearmedizinische Entzuendungsdiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R. [Klinikum Bremen-Mitte, Bremen (Germany). Klinik fuer Nuklearmedizin; Kuwert, T. [Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik

    2011-03-15

    Even today infection remains a significant concern, and the diagnosis and localization of infectious foci is an important health issue. As an established infection-imaging modality, nuclear medicine plays a vital health-care role in the diagnosis and subsequent effective treatment of this condition. Several techniques in nuclear medicine significantly aid infection diagnosis, including triple-phase bone scanning, {sup 18}F-FDG-PET and imaging with {sup 111}In-oxine-, {sup 99m}Tc-HMPAO-labeled leukocytes. Each radiopharmaceutical has specific advantages and disadvantages that makes it suitable to diagnose different infectious processes (e.g., soft-tissue sepsis, inflammatory bowel disease, osteomyelitis, occult fever, fever of unknown origin, and infections commonly found in immuno-compromised patients). However, their clinical applications may be limited by the relatively low spatial resolution and the lack of anatomic landmarks of a highly specific tracer with only scarce background uptake to use as a framework for orientation. Anatomic imaging modalities such as CT provide a high-quality assessment of structural abnormalities related to infection, but these structural abnormalities may be unspecific. Furthermore, to detect infection before anatomical changes are present, functional imaging could have some advantages over anatomical imaging. Scintigraphic studies have demonstrated high sensitivity and specificity to an infectious process. Diagnosis and precise delineation of infection may be challenging in certain clinical scenarios, rendering decisions concerning further patient management difficult. The SPECT/CT-technology combines the acquisition of SPECT and CT data with the same imaging device enabling perfect overlay of anatomical and functional images. SPECT/CT imaging data has been shown to be beneficial for many clinical settings such as indeterminate findings in bone scintigraphy, orthopaedic disorders, endocrine, and neuroendocrine tumors. Therefore

  11. Clinical study of cerebral blood flow in unilateral chronic subdural hematoma measured by {sup 99m}Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru [Kushiro Neurosurgical Hospital, Hokkaido (Japan); Aburano, Tamio

    2000-02-01

    Cerebral blood flow (CBF) measured by {sup 99m}Tc-HMPAO SPECT before operation was studied in 60 patients with unilateral chronic subdural hematoma. The regional CBF was measured in 26 regions of the fronto-occipital 10 cortices, putamen, thalamus and cerebellar hemisphere on both sides. Sixty cases with unilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms: 17 cases with headache (headache group), 34 cases with hemiparesis (hemiparesis group) and 9 cases with consciousness disturbance or dementia (consciousness disturbance group), and into three groups on the basis of the degree of midline brain shift on MRI: 7 cases of mild shift group, 24 cases of moderate shift group and 29 cases of severe shift group. The average CBF in 60 patients in each region indicated that the regional CBF was reduced in frontal, occipital cortices and cerebellum on the non-hematoma side, and in putamen and thalamus on the hematoma side. In the headache group, the regional CBF reduction on the non-hematoma side was found in only frontal and occipital cortices compared with the corresponding regions on the hematoma side. In the hemiparesis group, the regional CBF was reduced in frontal and occipital cortices on the non-hematoma side and in putamen and thalamus on the hematoma side. The part of CBF reduction in both hemispheres was also noted in the hemiparesis group. In the consciousness disturbance group, the CBF reduction was markedly noted in whole brain. The CBF reductions in frontal and occipital cortices on the non-hematoma side and in putamen, thalamus and cerebellum on the hematoma side was not mutually related with the degree of midline brain shift. We concluded that the disturbance of CBF in chronic subdural hematoma was started from frontal and occipital cortices on the non-hematoma side observed in the headache group, and which was extended to putamen and thalamus on the hematoma side and a part of both hemispheres observed in

  12. Optimization of Butterworth filter for brain SPECT imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Maruno, Hirotaka; Yui, Nobuharu

    1993-01-01

    A method has been described to optimize the cutoff frequency of the Butterworth filter for brain SPECT imaging. Since a computer simulation study has demonstrated that separation between an object signal and the random noise in projection images in a spatial-frequency domain is influenced by the total number of counts, the cutoff frequency of the Butterworth filter should be optimized for individual subjects according to total counts in a study. To reveal the relationship between the optimal cutoff frequencies and total counts in brain SPECT study, we used a normal volunteer and 99m Tc hexamethyl-propyleneamine oxime (HMPAO) to obtain projection sets with different total counts. High quality images were created from a projection set with an acquisition time of 300-seconds per projection. The filter was optimized by calculating mean square errors from high quality images visually inspecting filtered reconstructed images. Dependence between total counts and optimal cutoff frequencies was clearly demonstrated in a nomogram. Using this nomogram, the optimal cutoff frequency for each study can be estimated from total counts, maximizing visual image quality. The results suggest that the cutoff frequency of Butterworth filter should be determined by referring to total counts in each study. (author)

  13. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  14. Single photon emission computed tomography (SPECT): Clinical routine diagnosis of cerebral malfunction

    International Nuclear Information System (INIS)

    Neidl, K.F.W.

    1993-01-01

    Positron emission tomography is the gold standard for in vivo research in neurophysiology and pathology. The introduction of SPECT and the development of such tracers as 99m Tc-HMPAYO ( 99m Tc-d,l-hexamethylpropylenaminoxim) and, more recently, 123 I-iomazenil and 123 I-IBZM ( 123 I-3-iodo-6-methoxybenzamide) allowed closer examination of the perfusion of the brain and neuroreceptor density mapping in more than the few institutions that can afford PET and the production of special tracers marked with a positron emitting nucleus. Nuclear medicine's future will be based on neuroreceptor density mapping, as further tracers will become commercially available and no other technique can probably show such low concentrations of the receptors. Probably MR techniques will be used for brain's perfusion measurement in future. For examination of a limited cerebral region xenon-enhanced CT is an alternative to perfusion measurements with HMPAO, or a very interesting supplement. Of the old techniques in nuclear medicine, examination of the liquor dynamics is still feasible and well supplemented by SPECT. (orig./MG) [de

  15. Reversal of diaschisis by zolpidem

    International Nuclear Information System (INIS)

    Claus, R.P.; Nel, H.W.; Sathekge, M.

    2004-01-01

    Full text: Introduction: Recent literature has reported on clinical improvement after zolpidem, a GABAergic anti insomnia drug, in brain injury and stroke patients. In this study, the effect of zolpidem on crossed cerebellar diaschisis was investigated in such patients. Method: Four patients with crossed cerebellar diaschisis after brain injury or stroke were investigated before and after application of 10 mg zolpidem by 99mTc HMPAO brain SPECT. Result: Apart from clinical improvements, 99mTc HMPAO brain SPECT studies showed reversal of the crossed cerebellar diaschisis and improvement of perfusion defects after zolpidem. Conclusion: 99mTc HMPAO brain SPECT may have a role to pre-select brain injury and stroke patients who will benefit clinically from zolpidem therapy. (author)

  16. Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT.

    Science.gov (United States)

    Yamakami, I; Yamaura, A; Isobe, K

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99mtechnetium-hexamethyl propyleneamine oxime. Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient.

  17. Reduced contralateral hemispheric flow measured by SPECT in cerebellar lesions

    International Nuclear Information System (INIS)

    Soenmezoglu, K.; Sperling, B.; Lassen, N.A.; Henriksen, T.; Tfelt-Hansen, P.

    1993-01-01

    Four patients with clinical signs of cerebellar stroke were studied twice by SPECT using 99m Tc-HMPAO as a tracer for cerebral blood flow (CBF). When first scanned 6 to 22 days after onset, all had a region of very low CBF in the symptomatic cerebellar hemisphere, and a mild to moderate CBF reduction (average 10%) in contralateral hemispheric cortex. In all four cases clinical signs of unilateral cerebellar dysfunction were still present when rescanned 1 to 4 months later and the relative CBF decrease in the contralateral cortex of the forebrain also remained. The basal ganglia contralateral to the cerebellar lesion CBF showed variable alterations. A relative CBF decrease was seen in upper part of basal ganglia in all four cases, but it was not a constant phenomenon. A relative CBF increase in both early and late SPECT scans was seen at low levels of neostriatum in two cases. The remote CBF changes in cerebellar stroke seen in the forebrain are probably caused by reduced or abolished cerebellar output. The term ''Crossed Cerebral Diaschisis'' may be used to describe these CBF changes that would appear to reflect both decreased and increased neuronal activity. (au)

  18. Cerebral perfusion gammagraphy in neurology and neurosurgery

    International Nuclear Information System (INIS)

    Cardenas, Rene; Duran de Cardenas, Rosalia

    1998-01-01

    This paper describes six methods for measuring rCBF: 1) PET through 77 Kr, 15 O-water, 18 F-antipirine, 18 F-methane and 11 C-alcohols, 2) Wash measure of 133 Xe through SPECT or multidetectors, 3) CT contrasted through xenon, 4) planar gammagraphy or SPECT through 123 I-IMP or 123 I-HIPDM, 5) planar gammagraphy or radioisotopic tomography (SPECT) through 201 Tl-dietiltiocarbamate, and 6) planar gammagraphy or SPECT through 99m Tc lipofilics complex, 99m Tc-HMPAO and 99m Tc-ECD. They have been used for rCBF, , 133 Xe, 123 I-IMP 99m Tc-HMPAO studies, the two last ones are been used at the moment, the film performance is around 0.7 to 1.1 cm. The most useful radioisotopic techniques for gammagraphic study of cerebral perfusion have used HMPAO and 131 I-IMP labelled with 99m Tc

  19. Observation of the relationship between regional cerebral blood flow and brain functional changes in the patients with ischemic cerebrovascular diseases

    International Nuclear Information System (INIS)

    Guan Yihui; Lin Xiangtong; Liu Yongchang

    1994-01-01

    The brain perfusion SPECT imaging and functional changes in 27 patients with ischemic cerebrovascular diseases and 20 controls were investigated. Correlated with the clinical findings and MRI study, we discovered the lowered perfusion of Broca and Wernicke area is closely related with the aphasia caused by left basal ganglia infarction. In hemianopia group, as the visual function improved after the light stimulation treatment, the blood perfusion increased in occipital lobe. The lowered perfusion in vestibular center can be observed in vertigo group. From these studies, we concluded that 99m Tc-HMPAO brain SPECT imaging can partly reflect the brain functions

  20. Effects of auditory recall experience on regional cerebral blood flow as assessed by 99m-Tc-HMPAO SPECT in 13 Post Traumatic Stress Disorder patients

    International Nuclear Information System (INIS)

    Pagani, M.M.E.; Salmaso, D.; Soares, J.; Aberg-Wistedt, A.; Sundin, O.; Jacobsson, H.; Larsson, S.A.; Haellstroem, T.

    2002-01-01

    Aim: Post Traumatic Stress Disorder (PTSD) is a severe condition affecting about 8% of population and increasing the risk of depression. PTSD patients, among other symptoms, suffer from intrusive distressing recollections of the traumatic event and avoidance of stimuli related to trauma. The aim of this study was to investigate the differences in regional cerebral blood flow (rCBF) between two groups of subjects exposed to the same type of traumatic stressor either developing PTSD or not. Materials and Methods: Thirteen subway drivers developing PTSD (PTSD) and 19 not developing PTSD (CTR) after being exposed to earlier person-under-the-train accident were included in the study. The rCBF distribution was compared between the two groups during a situation involving an auditory evoked re-experiencing of their traumatic event. 99m Tc-HMPAO SPECT, using a three-headed gamma camera, was performed and the radiopharmaceutical uptake in 7 bilateral regions of the brain was assessed using a standardised digitalised brain atlas. The chosen regions were those supposed to be involved in fear and emotional response and were located in the thalamus, limbic cortex and prefrontal, temporal and parietal lobes. Analysis of variance (ANOVA) was used to test the significance of the differences in flow in such functional regions. Results: In the global analysis, rCBF significantly differed between groups (0.04), hemispheres (p<0.02) and regions (p<0.0001). There was also a significant region x hemisphere interaction (p<0.0001). As compared to CTR, PTSD rCBF increased in the primary and associative auditory cortex (p<0.03) and in the temporal poles (p<0.02). Significant hemispheric differences were found in these latter regions (p<0.001 and p<0.0001, respectively), anterior cingulate cortex (p<0001) and multi-medial parietal association cortex (p<0.0001). Conclusions: Higher rCBF values in PTSD patients under recall of their traumatic experience were found as compared to CTR. The

  1. Cerebral blood flow and metabolism of the patients with a carotid stenosis evaluated by SPECT and 1H-MRS

    International Nuclear Information System (INIS)

    Uno, Masaaki; Nishi, Kyouko; Shinno, Kiyohito; Nagahiro, Shinji; Ohtsuka, Hideki; Harada, Masafumi

    1998-01-01

    We examined cerebral blood flow (CBF) and metabolic states in patients with a severe carotid stenosis by SPECT and proton MRS ( 1 H-MRS). SPECT using 99m Tc-HMPAO and 1 H-MRS were performed in twenty five patients with over 70% carotid stenosis. Moreover, 10 patients were evaluated by these methods after carotid endarterectomy (CEA). N-acetyl-aspartate (NAA) on the ipsilateral side was reduced in 17 patients (Group A) while NAA of other 8 patients was not reduced (Group B). In Group A, although regional CBF was reduced in only 4 of 17 patients, 11 patients showed decline of cerebral vasoreactivity evaluated by acetazolamide injection. Concentration of NAA and regional CBF showed significant correlations. After CEA, ipsilateral NAA was increased significantly compared to preoperative NAA level. In 6 of 7 patients in Group A, cerebral vasoreactivity also improved postoperatively. These results indicated that ipsilatereal NAA metabolism and cerebral vasoreactivity can be improved after CEA. SPECT and 1 H-MRS were useful to evaluate CBF and metabolism in patients with carotid stenosis. (author)

  2. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Ichiseki, Hajime; Terashi, Akiro; Hamamoto, Makoto; Miyazaki, Tokuzo.

    1995-01-01

    We have performed single photon emission computed tomography (SPECT) with 99m Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author)

  3. Regional cerebral blood flow in status epileptics measured by single photon emission computed tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ichiseki, Hajime; Terashi, Akiro [Nippon Medical School, Tokyo (Japan); Hamamoto, Makoto; Miyazaki, Tokuzo

    1995-12-01

    We have performed single photon emission computed tomography (SPECT) with {sup 99m}Tc-hexamethylpropylene amineoxime (HM-PAO) to evaluate regional cerebral blood flow (rCBF) in status epileptics (SE) caused by a cerebral vascular accident. In addition, we have discussed the neurophysiology of SE based on the SPECT findings. A total of sixteen patients (5 males and 11 females, average age; 78.2 years old) with SE who were suffering from prolonged consciousness disturbance were investigated. When SPECT was performed in the ictal state, there was a remarkable increase in radio isotope (RI) uptake at the focus which correlated well with EEG findings. However, in other cortical regions, basal ganglia and thalamus, there was a relatively demonstrated decrease in RI uptake compared with that of the focus. Additionally in the interictal state, we found a decrease in RI uptake in the epileptic foci and normal recovery of the RI uptake level in other cerebral regions. We speculate that these characteristic patterns of cerebral blood flow distribution shown by SPECT scans in the ictal state reflect the state of consciousness disturbance due to SE. In general, in the elderly, it is difficult to make a differential diagnosis between prolonged consciousness disturbance due to nonconvulsive SE and other diseases such as cardiovascular diseases, dehydration, metabolic disorder, etc. Nevertheless, nonconvulsive SE causes diffuse cell loss and irreversible brain damage. Therefore the elderly who have suffered from prolonged consciousness disturbance due to SE need an exact diagnosis and immediate medical treatment. When we diagnose a nonconvulsive SE, the characteristic findings of SPECT scans in the ictal state are very clear and useful. In conclusion, SPECT is a very simple and non-invasive method that demonstrates abnormalities of brain function exactly. Therefore, we should perform not only EEC but also SPECT scans when making a diagnosis of SE. (author).

  4. Regional cerebral blood flow assessed by single photon emission computed tomography (SPECT) in dogs with congenital portosystemic shunt and hepatic encephalopathy.

    Science.gov (United States)

    Or, Matan; Peremans, Kathelijne; Martlé, Valentine; Vandermeulen, Eva; Bosmans, Tim; Devriendt, Nausikaa; de Rooster, Hilde

    2017-02-01

    Regional cerebral blood flow (rCBF) in eight dogs with congenital portosystemic shunt (PSS) and hepatic encephalopathy (HE) was compared with rCBF in eight healthy control dogs using single photon emission computed tomography (SPECT) with a 99m technetium-hexamethylpropylene amine oxime ( 99m Tc-HMPAO) tracer. SPECT scans were abnormal in all PSS dogs. Compared to the control group, rCBF in PSS dogs was significantly decreased in the temporal lobes and increased in the subcortical (thalamic and striatal) area. Brain perfusion imaging alterations observed in the dogs with PSS and HE are similar to those in human patients with HE. These findings suggest that dogs with HE and PSS have altered perfusion of mainly the subcortical and the temporal regions of the brain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Assessment of the brain areas perfused by superselective intra-arterial chemotherapy using single photon emission computed tomography with technetium-99m-hexamethyl-propyleneamine oxime. Technical note

    Energy Technology Data Exchange (ETDEWEB)

    Namba, Hiroki; Iwadate, Yasuo; Saegusa, Takashi; Sueyoshi, Kanji [Chiba Cancer Center Hospital (Japan); Kobayashi, Shigeki; Sato, Akira; Watanabe, Yoshiro

    1994-12-01

    The brain areas perfused by superselective intra-arterial (i.a.) chemotherapy were assessed using single photon emission computed tomography (SPECT) with technetium-99m-hexamethyl-propyleneamine oxime ({sup 99m}Tc-HMPAO). A superselective catheter was introduced into the anterior, middle, or posterior cerebral artery of patients with malignant glioma for i.a. chemotherapy. {sup 99m}Tc-HMPAO was subsequently injected via the same catheter used for chemotherapy, and a higher dose of {sup 99m}Tc-HMPAO was injected intravenously to obtain adequate background brain images. Comparison of the SPECT images with magnetic resonance images could confirm complete perfusion of the tumor tissue. In two patients with malignant glioma, regions of interest were selected in the peritumoral brain area and a reference brain area, and the radioactivity was measured. The concentration of {sup 99m}Tc-HMPAO was about 50 times higher in tissue perfused by superselective injection into anterior or middle cerebral artery compared to intravenous injection. {sup 99m}Tc-HMPAO SPECT is readily available in many institutions and the information provided is useful for planning more effective and safe i.a. chemotherapy. (author).

  6. Advances in regional cerebral blood flow measurement and patho-physiological analysis by SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo (Niigata Univ. (Japan). School of Medicine)

    1994-04-01

    Recently, two kinds of radiopharmaceuticals have been developed to represent the biodistribution of regional blood flow, which are N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and [sup 99m]Tc-hexamethylpropylene-amine-oxime (HMPAO). The charachteristics, clinical usage and imitation of these two radiolabeled agents are discussed. The advantage of [sup 123]I-IMP is that it has high first-pass extraction and long retention in brain tissue, hence it can be used to measure the absolute values of regional cerebral blood flow (rCBF). When the kinetics of [sup 123]I-IMP is assumed to be freely diffusible in the brain, its behavior is considered by 2-compartment model, especially which is assumed by the microsphere model in the early period after the i.v. injection of [sup 123]I-IMP. Comparing the rCBF measured by [sup 123]I-IMP with that by [sup 133]Xe inhalation SPECT method, we have to consider PaCO[sub 2] when both SPECT studies are performed, because PaCO[sub 2] is one of the big factors which make effects on the alteration of rCBF. [sup 123]I-IMP has an interesting character of the redistribution phenomenon which represrent the degree of ischemia in the cerebrovascular diseases. Distribution volume an important datum obtained by the SPECT study with [sup 123]I-IMP, which represent the degree of retention, i.e. binding potential of [sup 123]I-IMP in the brain tissue. I introduced the usage of the distribution volume of [sup 123]I-IMP, which was constructed in the rate constant square method, in the differential diagnosis of Parkinson's disease and progressive supranuclear palsy (PSP). The clinical usage of [sup 99m] Tc-HMPAT was mentioned, the advantage of which is the rapid fixation in the brain tissue and the distribution does not change for long time after the i.v. injection. Hence [sup 99m]Tc-HMPAO is used for the diagnosis of epileptic foci and certain loading tests such as balloon occlusion test, postural test and acetazolamide loading test. (author).

  7. Use of 99mTc-HMPAO cerebral tomo-scintigraphy in follow-up of patients afflicted with the Alzheimer's disease and treated by TACRINE

    International Nuclear Information System (INIS)

    Mestas, D.; Catoire, S.; Jalenques, I.; Maublant, J.; Veyre, A.

    1997-01-01

    A simultaneous study of the cognitive functions, single photon emission tomography (SPECT) and quantified electroencephalogram (qEEG) was carried out in 23 patients afflicted with the Alzheimer's disease and pursued during 1 year of treatment by TACRINE. A psycho-metric examination was done at inclusion and one year after; the qEEG was effected at inclusion, 6 months and one year later, while the four SPECT by HMPAO- 99m Tc (925 MBq) examinations were performed at inclusion, 12 weeks, 6 months and one year after. Two qEEG parameters were retained: the posterior average frequency (PAF) and the total spectrum power (TSP). Semi-quantitative measurements of the cerebral blood rate were determined on 4 cortical regions of interest, their average activity being referred to the average maximal activity of the cerebellum. Two variables were analyzed: the lowest value of the ratio (LVR) and the mean value of 4 ratios (MVR). The results produced an evolution significantly correlated to the PAF while psychometric tests and a correlation of the severity of cognitive affliction with the MVR at inclusion and one year after; as for LVR, it occurred in our study the most pertinent for pursuing the evolution of patients. In conclusion, the SPECT and the qEEG applied in parallel to the cognitive functions of the patients treated by TACRINE, appears to be interesting in evaluating the therapeutic response

  8. Brain perfusion SPECT of patients with anorexia nervosa. Evaluation using statistical parametric mapping (SPM96)

    Energy Technology Data Exchange (ETDEWEB)

    Nakabeppu, Yoshiaki; Nakajoh, Masayuki; Tsuchimochi, Shinsaku; Tani, Atsushi; Umanodan, Tomokazu [Kagoshima Univ. (Japan). Faculty of Medicine; Naruo, Tetsuro; Nozoe, Shinichi

    2001-02-01

    Anorexia nervosa (AN) has two subtypes; restricting type (AN-R) and binge-eating/purging type (AN-BP). It is suggested that AN-R is different from AN-BP on psychopathological aspects. We compared regional cerebral blood flows of 7 female patients with AN-R, 7 female patients with AN-BP and 7 age-matched normal volunteers (NV) using Tc99m-HMPAO SPECT processed by SPM96. There were significant decreased perfusions in the anterior cingulate gyrus in AN-R when compared with those of AN-BP and NV. These results suggest that the mechanism of outbreak of AN-R may be different from that of AN-BP. (author)

  9. Brain perfusion SPECT of patients with anorexia nervosa. Evaluation using statistical parametric mapping (SPM96)

    International Nuclear Information System (INIS)

    Nakabeppu, Yoshiaki; Nakajoh, Masayuki; Tsuchimochi, Shinsaku; Tani, Atsushi; Umanodan, Tomokazu; Naruo, Tetsuro; Nozoe, Shinichi

    2001-01-01

    Anorexia nervosa (AN) has two subtypes; restricting type (AN-R) and binge-eating/purging type (AN-BP). It is suggested that AN-R is different from AN-BP on psychopathological aspects. We compared regional cerebral blood flows of 7 female patients with AN-R, 7 female patients with AN-BP and 7 age-matched normal volunteers (NV) using Tc99m-HMPAO SPECT processed by SPM96. There were significant decreased perfusions in the anterior cingulate gyrus in AN-R when compared with those of AN-BP and NV. These results suggest that the mechanism of outbreak of AN-R may be different from that of AN-BP. (author)

  10. A limitation of the split-dose method for evaluating rCBF changes using 99mTc-ECD and SPECT

    International Nuclear Information System (INIS)

    Odano, Ikuo; Takahashi, Makoto; Noguchi, Eikichi; Ohtaki, Hiro; Shibaki, Mitsurou; Kasahara, Tosifumi; Hatano, Masayoshi; Ohkubo, Masaki.

    1997-01-01

    The purpose of the study is to validate the split-dose method corrected with dose ratio of 99m Tc-ECD for brain perfusion scan. A dose of 600 MBq of 99m Tc-ECD was divided into two with various dose ratios from 1 : 1 to 1 : 4, and injected to eleven patients with various cerebral diseases. A lesser dose of 99m Tc-ECD was injected under a control state for the first SPECT scan, and 15 min SPECT scan was performed 10 min after injection with a triple-head high resolution gamma camera. After the scan, the other dose of 99m Tc-ECD was injected under the same control state and the second SPECT scan was performed as same as above. A ratio of the activity of the first scan to the net activity of the second scan corrected by dose ratio, defined as K, was measured in brain regions of each subject. Expected value of K was 1, but the value was distributed with large variations in each subject. The mean % error of the K value was 10.4±4.9%. Hence it is considered that activity changes by more than 20% from the control values should be required to detect a significant rCBF change in an activation SPECT study. Then, we proposed a new method in which the activity of both two SPECT scans was normalized by cerebellar or occipital activity and compared. The ratio obtained by the proposed method came closer to 1 with less variations and with less mean % error in comparison with those of K value obtained by the dose-correction method. Although the proposed method has a limitation in the use of an activation study loaded with Diamox, it may be useful to evaluate an alteration of rCBF in the study such as postural testing or finger-moving test. (author)

  11. Simultaneous effect of chronic repetitive transcranial magnetic stimulation on RCBF and RCMR in depressive patients

    International Nuclear Information System (INIS)

    Peschina, W.; Conca, A.; Fritzsche, H.; Koenig, P.

    2002-01-01

    Full text: The basic principle of repetitive transcranial magnetic stimulation (rTMS) is the electromagnetic induction: depending on the field strength (up to 2 Tesla) neurons are frequency-dependent stimulated or inhibited. This method allows a non-invasive and painless investigation of sensomotoric and higher cortical functions. Brain imaging studies can visualize cerebral perfusion and metabolism, as they are influenced by rTMS. The aim of our study was to analyze the patterns of regional cerebral glucose uptake rate (rCMRGIu) and regional 99m Tc HMPAO uptake rate (rCBF) simultaneously during a treatment course of rTMS at low frequency. Four drug resistant depressed patients underwent 10 rTMS as add-on measure over 14 days. One day before and one day alter TMS series 511 KeV SPECT with 18 F-FDG and 99m Tc HMPAO simultaneous measurements were carried out. We used a standard double-head camera with a 511 keV-collimator. The two isotope doses were injected simultaneously. Acquisition was done with a double-isotope, there-window technique, where the third window was used for the registration of compton scatter. After applying Chang's attenuation correction and a simultaneous reorientation of the two datasets, a semiquantitative evaluation with 16 regions per hemisphere was performed. All patients showed a good clinical outcome. Statistically significant common changes of rCBF and rCMRGlu pattern were found in the upper frontal regions bilaterally in terms of increased uptake rates and in the left orbitofrontal cortex in terms of decreased uptake rates of both isotopes compared to controls. Furthermore, the lateralization pattern of rCBF and rCMRGlu after rTMS treatment revealed marked differences. Thus, despite no relevant changes of lateralization on the glucose uptake were observed, a clear right-sided preponderance of rCBF also in areas remote from the stimulation side was described. Therapeutic rTMS seems to influence distinct, cortical regions affecting r

  12. A limitation of the split-dose method for evaluating rCBF changes using {sup 99m}Tc-ECD and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo; Takahashi, Makoto; Noguchi, Eikichi; Ohtaki, Hiro; Shibaki, Mitsurou; Kasahara, Tosifumi; Hatano, Masayoshi [Niigata Univ. (Japan). School of Medicine; Ohkubo, Masaki

    1997-05-01

    The purpose of the study is to validate the split-dose method corrected with dose ratio of {sup 99m}Tc-ECD for brain perfusion scan. A dose of 600 MBq of {sup 99m}Tc-ECD was divided into two with various dose ratios from 1 : 1 to 1 : 4, and injected to eleven patients with various cerebral diseases. A lesser dose of {sup 99m}Tc-ECD was injected under a control state for the first SPECT scan, and 15 min SPECT scan was performed 10 min after injection with a triple-head high resolution gamma camera. After the scan, the other dose of {sup 99m}Tc-ECD was injected under the same control state and the second SPECT scan was performed as same as above. A ratio of the activity of the first scan to the net activity of the second scan corrected by dose ratio, defined as K, was measured in brain regions of each subject. Expected value of K was 1, but the value was distributed with large variations in each subject. The mean % error of the K value was 10.4{+-}4.9%. Hence it is considered that activity changes by more than 20% from the control values should be required to detect a significant rCBF change in an activation SPECT study. Then, we proposed a new method in which the activity of both two SPECT scans was normalized by cerebellar or occipital activity and compared. The ratio obtained by the proposed method came closer to 1 with less variations and with less mean % error in comparison with those of K value obtained by the dose-correction method. Although the proposed method has a limitation in the use of an activation study loaded with Diamox, it may be useful to evaluate an alteration of rCBF in the study such as postural testing or finger-moving test. (author)

  13. Clinical use of regional Tc-99m-HMPAO uptake in dementia of the Alzheimer type (DAT). Klinische Wertigkeit des regionalen [sup 99m]Tc-HMPAO Uptake bei der Demenz vom Alzheimer-Typ (DAT)

    Energy Technology Data Exchange (ETDEWEB)

    Gebhardt, U [Nuklearmedizinische Klinik und Poliklinik, TU Muenchen (Germany); Schmauss, F [Nuklearmedizinische Klinik und Poliklinik, TU Muenchen (Germany); Wagner-Manslau, C [Nuklearmedizinische Klinik und Poliklinik, TU Muenchen (Germany); Buttermann, G [Nuklearmedizinische Klinik und Poliklinik, TU Muenchen (Germany); Zimmer, R [Psychiatrische Klinik, TU Muenchen (Germany)

    1993-12-01

    In 46 patients with dementia of the Alzheimer type (DAT) regional cerebral blood flow (rCBF) was compared with cognitive performance (MMSE, CAMCOG). The cortico-cerebellar ratio (CCR), determined by [sup 99m]Tc-HMPAO-SPECT was used as a rCBF-equivalent. In the mild demented group we found a bilateral CCR-reduction parietal posterior, in moderate DAT bilateral temporoparietal and leftsided frontolateral defects were seen. Severe DAT showed an additional perfusion decrease mid frontal. With increasing severity of DAT an asymmetric perfusion occurred in 17/46 patients with accentuated CCR-reduction on the left side (temporal>parietal). High correlations between CCR and MMSE (r[>=]0.70) existed frontolateral, temporal and parietal in the left hemisphere. Significant associations between CCR and CAMCOG were obtained for language in the left temporal posterior region (r=0.64), for memory task left temporal anterior (r=0.59) and for praxis left parietal posterior (r=0.55). In detecting rCBF abnormalities the sensitivity for all 46 DAT patients was 91% and 70% in the mild cases. (orig.)

  14. Evaluation of lung injury induced by pingyangmycin with 99Tcm-HMPAO lung imaging

    International Nuclear Information System (INIS)

    Zhao Changjiu; Yang Zhijie; Fu Peng; Zhang Rui

    2005-01-01

    Objective: To investigate the lung uptake of 99 Tc m -hexamethyl propylene amine oxime (HMPAO) in pingyangmycin-induced lung injury and its mechanism. Methods: 24 white rabbits were randomly divided into 4 groups. Group I: the control with normal diet. In group II, III and IV 0.2, 0.3 and 0.5 mg/kg pingyangmycin were given respectively by marginal vein of ear every other day. 99 Tc m -HMPAO static lung imaging was performed before and 8, 16, 24, 32 d after injection of pingyangmycin. 7 pixel x 5 pixel regions of interest (ROIs) were drawn on the right lung(R) and right upper limb(B), R/B were calculated. Also, 2 ml venous blood was withdrawn for measurement of endothelin by radioimmunoassay. 16 d after pingyangmycin in group IV and 32 d in group I, II and III, all the rabbits were sacrificed. Both lungs were examined immediately under light and electron microscopy. Results: Compared with the control group, there were statistical differences of 99 Tc m -HMPAO lung uptake in group II, III and IV (P 99 Tc m -HMPAO lung imaging can detect early pingyangmycin-induced lung injury. The endothelium of lung microcapillary is presumably the main location site of 99 Tc m -HMPAO abnormal concentration. (authors)

  15. Combining SPECT and Quantitative EEG Analysis for the Automated Differential Diagnosis of Disorders with Amnestic Symptoms

    Directory of Open Access Journals (Sweden)

    Yvonne Höller

    2017-09-01

    Full Text Available Single photon emission computed tomography (SPECT and Electroencephalography (EEG have become established tools in routine diagnostics of dementia. We aimed to increase the diagnostic power by combining quantitative markers from SPECT and EEG for differential diagnosis of disorders with amnestic symptoms. We hypothesize that the combination of SPECT with measures of interaction (connectivity in the EEG yields higher diagnostic accuracy than the single modalities. We examined 39 patients with Alzheimer's dementia (AD, 69 patients with depressive cognitive impairment (DCI, 71 patients with amnestic mild cognitive impairment (aMCI, and 41 patients with amnestic subjective cognitive complaints (aSCC. We calculated 14 measures of interaction from a standard clinical EEG-recording and derived graph-theoretic network measures. From regional brain perfusion measured by 99mTc-hexamethyl-propylene-aminoxime (HMPAO-SPECT in 46 regions, we calculated relative cerebral perfusion in these patients. Patient groups were classified pairwise with a linear support vector machine. Classification was conducted separately for each biomarker, and then again for each EEG- biomarker combined with SPECT. Combination of SPECT with EEG-biomarkers outperformed single use of SPECT or EEG when classifying aSCC vs. AD (90%, aMCI vs. AD (70%, and AD vs. DCI (100%, while a selection of EEG measures performed best when classifying aSCC vs. aMCI (82% and aMCI vs. DCI (90%. Only the contrast between aSCC and DCI did not result in above-chance classification accuracy (60%. In general, accuracies were higher when measures of interaction (i.e., connectivity measures were applied directly than when graph-theoretical measures were derived. We suggest that quantitative analysis of EEG and machine-learning techniques can support differentiating AD, aMCI, aSCC, and DCC, especially when being combined with imaging methods such as SPECT. Quantitative analysis of EEG connectivity could become

  16. Preliminary study on the head-injury by using SPECT with 99mTc-HMPAO

    International Nuclear Information System (INIS)

    Guan Yihui; Liu Yongchang; Lin Xiangtong

    1994-01-01

    After the acute period of head trauma some cases of patients may have some symptoms, such as headache, poor memory, vertigo, et al. In this study, among 42 patients most of whom had normal CT or MRI abnormal findings of brain perfusion imaging were seen in 33 patients (78.6%). Multiple perfusion defects were observed in some patients (13/42). These indicate that the head-injury syndrome is closely related to brain blood perfusion. authors' conclusion is that the brain SPECT is able to find out the etiology of head injury syndrome

  17. Tc-99m-HMPAO-Labeled leukocyte SPECT/CT in pediatrics: detecting Candida albicans tricuspid endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Calais, Jeremie; Edet-Sanson, Agathe; Gaucher, Stephane; Vera, Pierre; Cloirec, Joseph Le [Henri Becquerel Cancer Center and Rouen Univ. Hospital, Rouen (France)

    2015-12-15

    These results led to performing TEE, which showed tricuspid vegetation. Blood cultures were then positive to Candida albicans. Control blood cultures and TEE performed 6 weeks later after adapted antifungal therapy remained negative. In accordance with the results of Erba and al., this case illustrates the usefulness of late thoracic SPECT-CT acquisition of a WBC scan in a patient with high clinical suspicion of endocarditis and identified risk factors but inconclusive echocardiographic findings.

  18. Tc-99m-HMPAO-Labeled leukocyte SPECT/CT in pediatrics: detecting Candida albicans tricuspid endocarditis

    International Nuclear Information System (INIS)

    Calais, Jeremie; Edet-Sanson, Agathe; Gaucher, Stephane; Vera, Pierre; Cloirec, Joseph Le

    2015-01-01

    These results led to performing TEE, which showed tricuspid vegetation. Blood cultures were then positive to Candida albicans. Control blood cultures and TEE performed 6 weeks later after adapted antifungal therapy remained negative. In accordance with the results of Erba and al., this case illustrates the usefulness of late thoracic SPECT-CT acquisition of a WBC scan in a patient with high clinical suspicion of endocarditis and identified risk factors but inconclusive echocardiographic findings

  19. Brain perfusion SPECT and EEG findings in Rett syndrome

    International Nuclear Information System (INIS)

    Lappalainen, R.; Liewendahl, K.; Nikkinen, P.; Sainio, K.; Riikonen, R.S.

    1997-01-01

    Thirteen patients (mean age 8.4 + 5.3 years) with Rett syndrome (RS) were studied with EEG and 99m Tc-HMPAO SPECT. Eleven patients had background abnormalities and 10 patients paroxysmal activity in EEG. Hypoperfusion of varying severity was detected in 11 patients, 7 patients having multiple lesions. Bifrontal hypoperfusion, observed in 6 patients, was the most distinctive finding. Hypoperfusion was observed also in other cortical regions, except for the occipital lobes. There was no correlation between severity of the background abnormality or presence of paroxysmal activity in EEG and grade of hypoperfusion. There was, however, an association between the severity of hypoperfusion and early manifestation of symptoms in patients with RS. Whether this early-onset group of patients represents a different disease entity or only reflects disease variability the basic pathology being the same, is a possibility that deserves further clarification. (au) 37 refs

  20. Diagnosis of functional loss using with PET or SPECT

    International Nuclear Information System (INIS)

    Maeda, Tetsuya; Nagata, Ken

    2009-01-01

    Described are outlines of positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging, and their application to diagnosis of brain diseases accompanying functional loss. PET imaging by annihilation photons is useful to see the brain metabolic activity with use of compounds labeled by positron emitters like 11 C, 15 O, 13 N and 18 F. Cerebral blood flow (CBF), CB volume and oxygen extraction fraction correlate well with the cerebral activity and can be measured by PET with C 15 O 2 , H 2 15 O or 15 O 2 . 18 F-glucose is usable to measure the cerebral metabolic rate of glucose. SPECT imaging by γ-rays of 133 Xe, 123 I-iofetamine (IMP), 99m Tc-hexamethyl propylene amine oxime (HMPAO) and 99m Tc-ethyl cysteinate dimer (ECD) is useful also to measure CBF in different mechanisms from agent to agent, which often reflect the pathophysiology of the lesion in problem. These imaging techniques are applied to the diagnosis of regional functional loss in ischemic brain diseases like infarction, dementia (Alzheimer and multiple vascular) and Parkinsonism, of which characters and details of actual images are presented herein. Authors say that although the imaging diagnosis for brain functional loss has progressed, the integration of neurological finding, clinical process and simple morphological brain image as well is still important in the routine examination. (K.T.)

  1. The GABA-A benzodiazepine receptor complex: Role of pet and spect in neurology and psychiatry; Der GABA-A-benzodiazepinrezeptorkomplex: Rolle von PET und SPECT in Neurologie und Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Juengling, F.D. [Abt. fuer Nuklearmedizin, Radiologie III, Universitaetsklinik Ulm (Germany); Schaefer, M.; Heinz, A. [Klinik fuer Psychiatrie und Psychotherapie, Charite, Humboldt-Univ. zu Berlin (Germany)

    2002-09-01

    Nuclear medicine imaging techniques such as positron emission tomography (PET) and single photon emission tomography (SPECT) for selective depiction of GABA-A-benzodiazepine receptor (GBZR) binding are complementary investigations in the diagnostic process of neurological and psychiatric disorders. This review summarizes the current knowledge about options and limitations of PET and SPECT for in vivo diagnostics in neurology and psychiatry. The growing importance of GBZR-imaging for the understanding of pathophysiology and pharmacological treatment in different psychiatric syndromes is discussed. (orig.) [German] Mit der Entwicklung selektiver Liganden fuer den GABA-A-Benzodiazepinrezeptorkomplex (GBZR) hat die nuklearmedizinische Bildgebung mittels positronen-emissionstomographie (PET) und single-photon-emissionscomputertomographie (SPECT) einen festen Stellenwert fuer Klinik und Forschung in der Neurologie und Psychiatrie erlangt. Die vorliegende Ueberblicksarbeit fasst den aktuellen Wissensstand von Anwendungsmoeglichkeiten und -grenzen der nuklearmedizinischen Bildgebung der GBZR in vivo zusammen und beleuchtet ihren klinischen Nutzen. Die wachsende Bedeutung fuer das Verstaendnis der Pathophysiologie und pharmakotherapeutischer Konzepte unterschiedlicher psychiatrischer Erkrankungen wird herausgestellt. (orig.)

  2. Inflammation Scan Using {sup 99m}Tc-HMPAO Labelled Leukocytes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Woo Jin; Chung, Soo Kyo; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Hoon Kyo [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1989-07-15

    Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP -32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and {sup 99m}Tc-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. {sup 99m}Tc is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HMPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plans to improve the viability of the leukocytes. Inflammation scan using {sup 99m}Tc-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with {sup 99m}Tc-HMPAO in three dogs 24 hours after inoculation of live E. Coli and S. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with {sup 99m}Tc-HMPAO in 20% cell free plasma diluted with phosphate buffer solution. Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder. Uptake of labelled leukocytes in the inflammation site was definite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio. 4). Inflammation

  3. Evaluation of brain perfusion SPECT imaging using 99mTc-ECD

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Kinuya, Keiko; Higashi, Sotaro; Kawasaki, Yasuhiro; Sumiya, Hisashi; Shuke, Noriyuki; Hisada, Kinichi; Yamashita, Junkoh; Yamaguchi, Nariyoshi

    1991-01-01

    Fundamental and clinical evaluation was performed on 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD), that is a new agent for brain perfusion SPECT. Radiochemical purity reaches a plateau of approximately 98% at 30 min after reconstruction and remains stable up to 24 hours later. A biodistribution study showed approximately 5% injected dose in the brain, very slow brain washout of 5.6% per hour on the average, and rapid washout from the other organ mainly through the urinary system. Brain ECD distribution was determined within 2 min postinjection and remained stable for up to 1 hour. Three hours later, slight but significant changes in brain distribution were observed, that were relative reduction of cerebral cortical activity and gray to white matter activity ratio, and relative elevation of white matter and thalamic activities. Comparative studies of ECD images with 123 I-iodoamphetamine (IMP) and 99m Tc-d, l-hexa-methylpro-pyleneamine oxime (HMPAO) images revealed that radioactivity contrast between affected and unaffected areas was less prominent in ECD than in IMP in cerebral and cerebellar cortical lesions, more prominent in ECD than in IMP in striatal and thalamic lesions, and somewhat more prominent in ECD than in HMPAO in both lesions. Imaging around 1 hour postinjection seems to be more appropriate than immediate postinjection imaging because of the clearance of the extracranial radioactivity and somewhat better radioactivity contrast between affected and unaffected areas. (author)

  4. Clinical usefulness of scatter and attenuation correction for brain single photon emission computed tomography (SPECT) in pediatrics

    International Nuclear Information System (INIS)

    Adachi, Itaru; Doi, Kenji; Komori, Tsuyoshi; Hou, Nobuyoshi; Tabuchi, Koujirou; Matsui, Ritsuo; Sueyoshi, Kouzou; Utsunomiya, Keita; Narabayashi, Isamu

    1998-01-01

    This investigation was undertaken to study clinical usefulness of scatter and attenuation correction (SAC) of brain SPECT in infants to compare the standard reconstruction (STD). The brain SPECT was performed in 31 patients with 19 epilepsy, 5 cerebro-vascular disease, 2 brain tumor, 3 meningitis, 1 hydrocephalus and psychosis (mean age 5.0±4.9 years old). Many patients was necessary to be injected sedatives for restraining body motion after Technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO) was injected at the convulsion or rest. Brain SPECT data were acquired with triple detector gamma camera (GCA-9300 Toshiba Japan). These data were reconstructed by filtered backprojection after the raw data were corrected by triple energy windows method of scatter correction and Chang filtered method of attenuation correction. The same data was reconstructed by filtered backprojection without these corrections. Both SAC and STD SPECT images were analyzed by the visual interpretation. The uptake ratio of cerebral basal nuclei was calculated by the counts of the thalamus or lenticular nuclei divided by the cortex. All images of SAC method were excellent than that of STD method. The thalamic uptake ratio in SAC method was higher than that of STD method (1.22±0.09>0.87±0.22 p 1.02±0.16 p<0.01). Transmission scan is the most suitable method of absorption correction. But the transmission scan is not adequate for examination of children, because this scan needs a lot of time and the infants are exposed by the line source radioisotope. It was concluded that these scatter and absorption corrections were most suitable method for brain SPECT in pediatrics. (author)

  5. Cerebral perfusion changes in schizophrenia patients evaluated with Tc-99 HMPAO

    International Nuclear Information System (INIS)

    Sehweil, A.; El-Hilu, S.; Jahan, S.; Higazi, E.; Salhat, M.; Al-Mohannadi, S.; Abdel-Dayem, H.M.

    1989-01-01

    Tc-99m HMPAO has been used to image cerebral perfusion changes in 20 chronic schizophrenia patients (19 men and 1 woman), with an average age of 29 years (range, 22-48 years). All were receiving neuroleptic drugs. Twelve had received electroconvulsive therapy. All patients had abnormal studies (except one, which was normal) and poor response to treatment. Ventricular dilation and cerebral atrophy were seen in 11 patients. Seventy-seven focal lesions were detected. Forty-two lesions showed increased HMPAO retention: 26 in the basal ganglia in 14 patients (12, bilateral, two unilateral), 10 along the sylvian fissure in the parietotemporal region, three in the frontal region, and one in each of the temporal, parietal, and occipital regions. Thirty-five focal lesions showed decreased perfusion: 10 parietal, eight frontal, seven temporal, six cerebellar, and four occipital. This study demonstrates the potential value of Tc-99m HMPAO in the study of schizophrenia and other psychiatric disorders

  6. Design and evaluation of two multi-pinhole collimators for brain SPECT.

    Science.gov (United States)

    Chen, Ling; Tsui, Benjamin M W; Mok, Greta S P

    2017-10-01

    SPECT is a powerful tool for diagnosing or staging brain diseases such as Alzheimer's disease (AD) and Parkinson's disease (PD) but is limited by its inferior resolution and sensitivity. At the same time, pinhole SPECT provides superior resolution and detection efficiency trade-off as compared to the conventional parallel-hole collimator for imaging small field-of-view (FOV), which fits for the case of brain imaging. In this study, we propose to develop and evaluate two multi-pinhole (MPH) collimator designs to improve the imaging of cerebral blood flow and striatum. We set the target resolutions to be 12 and 8 mm, respectively, and the FOV at 200 mm which is large enough to cover the whole brain. The constraints for system optimization include maximum and minimum detector-to-center-of-FOV (CFOV) distances of 344 and 294 mm, respectively, and minimal radius-of-rotation (ROR) of 135 mm to accommodate patients' shoulder. According to the targeted FOV, resolutions, and constraints, we determined the pinhole number, ROR, focal length, aperture acceptance angle, and aperture diameter which maximized the system sensitivity. We then assessed the imaging performance of the proposed MPH and standard low-energy high-resolution (LEHR) collimators using analytical simulations of a digital NCAT brain phantom with 99m Tc-HMPAO/ 99m Tc-TRODAT-1 distributions; Monte Carlo simulations of a hot-rod phantom; and a Defrise phantom using GATE v6.1. Projections were generated over 360° and reconstructed using the 3D MPH/LEHR OS-EM methods with up to 720 updates. The normalized mean square error (NMSE) was calculated over the cerebral and striatal regions extracted from the reconstructed images for 99m Tc-HMPAO and 99m Tc-TRODAT-1 simulations, respectively, and average normalized standard deviation (NSD) based on 20 noise realizations was assessed on selected uniform 3D regions as the noise index. Visual assessment and image profiles were applied to the results of Monte Carlo

  7. Cerebral perfusion abnormalities in therapy-resistant epilepsy in mentally retarded pediatric patients

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.M.; Nawaz, K.; Hassoon, M.; Rahman, M.; Olofsson, O.E.

    1990-01-01

    This paper identifies sites of cerebral perfusion abnormalities in therapy-resistant epilepsy in mentally retarded pediatric patients (TREMRPP) using Tc-99m HMPAO and to compare it with the results of electroencephalography (EEG) and fluorographic CT. Thirteen children underwent Tc-99m HMPAO single photon emission CT (SPECT) studies; 11 had fluorographic CT, and 12 had EEG (four had EEG twice). All studies for same patients were within 2 weeks of each other. SPECT studies were reviewed twice by two nuclear medicine physicians without any knowledge of the results of other tests. Fluorographic CT results showed cerebral atrophy in only three and were normal in eight. EEG results were abnormal in all 12 patients examined. Epileptogenic spikes (EPS) were seen in eight patients only. Tc-99m HMPAO SPECT studies were abnormal in all patients; they showed 21 foci of decreased perfusion on nine patients and nine foci of increased perfusion in seven patients (three patients had mixed lesions)

  8. Clinical use of regional Tc-99m-HMPAO uptake in dementia of the Alzheimer type (DAT)

    International Nuclear Information System (INIS)

    Gebhardt, U.; Schmauss, F.; Wagner-Manslau, C.; Buttermann, G.; Zimmer, R.

    1993-01-01

    In 46 patients with dementia of the Alzheimer type (DAT) regional cerebral blood flow (rCBF) was compared with cognitive performance (MMSE, CAMCOG). The cortico-cerebellar ratio (CCR), determined by 99m Tc-HMPAO-SPECT was used as a rCBF-equivalent. In the mild demented group we found a bilateral CCR-reduction parietal posterior, in moderate DAT bilateral temporoparietal and leftsided frontolateral defects were seen. Severe DAT showed an additional perfusion decrease mid frontal. With increasing severity of DAT an asymmetric perfusion occurred in 17/46 patients with accentuated CCR-reduction on the left side (temporal>parietal). High correlations between CCR and MMSE (r≥0.70) existed frontolateral, temporal and parietal in the left hemisphere. Significant associations between CCR and CAMCOG were obtained for language in the left temporal posterior region (r=0.64), for memory task left temporal anterior (r=0.59) and for praxis left parietal posterior (r=0.55). In detecting rCBF abnormalities the sensitivity for all 46 DAT patients was 91% and 70% in the mild cases. (orig.) [de

  9. Role of I-123-iomazenil SPEDT imaging in drug resistant epilepsy with complex partial seizures

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeholm, H.; Rosen, I.; Elmqvist, D. [Univ. Hospital, Dept. of Clinical Neurophysiology, Lund (Sweden)

    1995-07-01

    Fifteen patients with therapy resistant partial complex seizures with no structural lesions were examined interictally with 123-I-IOMAXENIL SPECT for measurement of benzodiazepine receptor distribution and with 99m-Tc-HMPAO SPEDT for measurement of cerebral blood flow distribution. Regional abnormalities were correlated with the seizure onset patterns in EEG later recorded with implanted subdural strips. SPECT scans were made immediately after and at 1 and 2 h after intravenous injection of 123-I-Iomaxenil. During that time there was a continuous change from an immediate flow-related distribution toward a more specific receptor distribution. The decay of radioactivity of I-123 in the brain was linear over time. Two patients on benzodiazepine treatment showed much faster elimination and showed no focal abnormalities. Eight patients with clear-cut unifocal seizure onset showed concordant focal benzodiazepine defects. These patients showed a progressive focus/homotopic non-focus enhancement over time much larger than the HMPAO scans in the same patients. Also the estimated focal area of abnormality was more restricted in the Iomazenil scans than in HMPAO scans. Five patients had more complex seizure onset patterns. In these patients a mismatch between the locations of abnormalities in Iomaxenil and HMPAO scans were often found but benzodiazepine receptor abnormalities were more circumscribed also in these patients. The results suggest that 123-I-Iomazenil SPECT is more useful than 99mTc-HMPAO SPECT when applied interictally in patients with partial complex epilepsy, since in addition to demonstrate the hemispheric laterality of the epileptogenic zone, 123-I-Iomazenil appears to indicate its anatomical location with higher confidence, which could be of practical value for positioning of intracranial EEG electrodes. (au) 36 refs.

  10. Development of 99mTc-labelled the d,1-diasteroisomer of HM-PAO for cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Lun Xiao.

    1989-10-01

    The d,1-diastereoisomer of hexamethyl propyleneamine oxime (HM-PAO) was selected as the preferred ligand for Tc-99m as a radiotracer for cerebral perfusion imaging. Further improvement of the synthesis and isolation method of HM-PAO resulted in pure d,1-HM-PAO and pure meso-HM-PAO. The neutral, lipophilic Tc-99m complexes of d,1-HM-PAO and meso-HM-PAO were formed in high yield by stannous reduction of Mo-99/Tc-99m generator eluate, respectively. Two minutes following i.v. administration of Tc-99m-d,1-HM-PAO in mice, 2.24% of the injected dose appears in the brain. Little washout of the tracer is observed up to 24-hour post injection. Two minutes following i.v. administration of Tc-99m-meso-HM-PAO in mice, 1.9% of the injected dose appears in the brain. The radioactivity of Tc-99m-meso-HM-PAO declined faster than that of Tc-99m-d,1-HM-PAO did in the brain up to 24-hour post injection. 12 refs, 5 figs, 5 tabs

  11. Evaluation of linear registration algorithms for brain SPECT and the errors due to hypoperfusion lesions

    International Nuclear Information System (INIS)

    Radau, Perry E.; Slomka, Piotr J.; Julin, Per; Svensson, Leif; Wahlund, Lars-Olof

    2001-01-01

    The semiquantitative analysis of perfusion single-photon emission computed tomography (SPECT) images requires a reproducible, objective method. Automated spatial standardization (registration) of images is a prerequisite to this goal. A source of registration error is the presence of hypoperfusion defects, which was evaluated in this study with simulated lesions. The brain perfusion images measured by 99m Tc-HMPAO SPECT from 21 patients with probable Alzheimer's disease and 35 control subjects were retrospectively analyzed. An automatic segmentation method was developed to remove external activity. Three registration methods, robust least squares, normalized mutual information (NMI), and count difference were implemented and the effects of simulated defects were compared. The tested registration methods required segmentation of the cerebrum from external activity, and the automatic and manual methods differed by a three-dimensional displacement of 1.4±1.1 mm. NMI registration proved to be least adversely effected by simulated defects with 3 mm average displacement caused by severe defects. The error in quantifying the patient-template parietal ratio due to misregistration was 2.0% for large defects (70% hypoperfusion) and 0.5% for smaller defects (85% hypoperfusion)

  12. In vitro comparison of HMPAO and gentisic acid for labelling leukocytes with 99mTc

    International Nuclear Information System (INIS)

    Ecclestone, M.; Proulx, A.; Ballinger, J.R.; Gerson, B.; Reid, R.H.; Gulenchyn, K.Y.

    1990-01-01

    Leukocytes can be labelled with 99m Tc using HMPAO and gentisic acid methods. We compared the two methods with respect to labelling efficiency on mixed leukocytes and isolated polymorphonuclear (PMN) and mononuclear (MN) cells, and the in vitro stability of the label. HMPAO produced approximately 70% labelling efficiency on mixed or PMN cells and the label was stable in saline or plasma. Labelling efficiency on MN was only 14% and was less stable. Gentisic acid produced a labelling efficiency of 52% on PMN and 35% on MN; both were stable in saline but less stable in plasma. In conclusion, HMPAO produces higher labelling efficiency and the label shows greater in vitro stability in plasma. However, gentistic acid is much less expensive to use, allows labelling of MN cells, and should result in more favourable microdosimetry. Preliminary clinical results suggest that gentistic acid is equivalent to HMPAO but has the advantage of being much cheaper. (orig.)

  13. Evaluation of distance-dependent resolution compensation in brain SPECT

    International Nuclear Information System (INIS)

    Badger, D.P.; Barnden, L.R.

    2010-01-01

    Full text: Conventional SPECT reconstruction assumes that the volume of response for each collimator hole is a cylinder, but due to the finite depth of the holes, the volume of response is actually cone shaped. This leads to a loss of resolution as the distance from the collimator face is increased. If distance-dependent resolution compensation (DRC) is incorporated into an iterative reconstruction algorithm, then some of the lost resolution can be recovered (T Yokoi, H Shinohara and H Onishi. 2002, Ann Nuc Med, 16, 11-18). ORC has recently been included in some commercial reconstruction software, and the aim of this study was to assess whether the significantly increased reconstruction processing time can be justified for clinical or for research purposes. HMPAO brain scans from 104 healthy subjects were reconstructed using iterative OSEM, with and without ORC. A voxel based iterative sensitivity (VBIS) technique was used for gain correction in the scans. A Statistical Parametric Mapping (SPM) analysis found the statistical strength of the SPECT aging effect increased when the non-DRC image set was compared to the images with ORC, probably due to improvement in the imaging of partial volume effects when the interhemispheric fissure and sulci enlarge with age (L Barnden, S Behin Ain, R Kwiatek, R Casse and L Yelland. 2005, Nuc Med Comm, 26, 497-503). It was concluded that the use of ORC is justified for research purposes, but may not be for routine clinical use. (author)

  14. Clinical usefulness of scatter and attenuation correction for brain single photon emission computed tomography (SPECT) in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Itaru; Doi, Kenji; Komori, Tsuyoshi; Hou, Nobuyoshi; Tabuchi, Koujirou; Matsui, Ritsuo; Sueyoshi, Kouzou; Utsunomiya, Keita; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1998-01-01

    This investigation was undertaken to study clinical usefulness of scatter and attenuation correction (SAC) of brain SPECT in infants to compare the standard reconstruction (STD). The brain SPECT was performed in 31 patients with 19 epilepsy, 5 cerebro-vascular disease, 2 brain tumor, 3 meningitis, 1 hydrocephalus and psychosis (mean age 5.0{+-}4.9 years old). Many patients was necessary to be injected sedatives for restraining body motion after Technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) was injected at the convulsion or rest. Brain SPECT data were acquired with triple detector gamma camera (GCA-9300 Toshiba Japan). These data were reconstructed by filtered backprojection after the raw data were corrected by triple energy windows method of scatter correction and Chang filtered method of attenuation correction. The same data was reconstructed by filtered backprojection without these corrections. Both SAC and STD SPECT images were analyzed by the visual interpretation. The uptake ratio of cerebral basal nuclei was calculated by the counts of the thalamus or lenticular nuclei divided by the cortex. All images of SAC method were excellent than that of STD method. The thalamic uptake ratio in SAC method was higher than that of STD method (1.22{+-}0.09>0.87{+-}0.22 p<0.01). The lenticular nuclear uptake ratio in SAC method was higher than that of STD method (1.26{+-}0.15>1.02{+-}0.16 p<0.01). Transmission scan is the most suitable method of absorption correction. But the transmission scan is not adequate for examination of children, because this scan needs a lot of time and the infants are exposed by the line source radioisotope. It was concluded that these scatter and absorption corrections were most suitable method for brain SPECT in pediatrics. (author)

  15. Neuropsychological functions and rCBF SPECT in Parkinson's disease patients considered candidates for deep brain stimulation

    International Nuclear Information System (INIS)

    Paschali, Anna; Lakiotis, Velissarios; Vassilakos, Paulos; Messinis, Lambros; Lyros, Epameinondas; Papathanasopoulos, Panagiotis; Constantoyannis, Costas; Kefalopoulou, Zinovia

    2009-01-01

    In the present study, we examined relationships between neuropsychological functions and brain single photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) observed at presurgical evaluation for deep brain stimulation (DBS) of the subthalamic nucleus (STN) in advanced Parkinson's disease (PD) patients. Twenty advanced non-demented PD patients, candidates for DBS surgery, underwent perfusion brain SPECT study and neuropsychological assessment prior to surgery (range: 30-50 days). Patients were further assessed using the Unified Parkinson's Disease Rating Scale (UPDRS) and Hoehn and Yahr (H and Y) scale. During all assessments patients were ''on'' standard medication. NeuroGam software, which permits voxel by voxel analysis, was used to compare the brain perfusion of PD patients with a normal database adjusted for sex and age. Neuropsychological scores were compared to age, education and sex-adjusted normative databases. Our results indicated that the distribution of rCBF showed significant differences when compared to an age- and sex-adjusted normative database. We found impaired blood flow in 17 (85%) of our patients in the left prefrontal lobe, in 14 (70%) in the right prefrontal lobe and in 11 (55%) in the left frontal and right parietal lobes. Neuropsychological testing revealed that 18 (90%) of our patients had significant impairments in measures of executive functions (set-shifting) and 15 (75%) in response inhibition. Furthermore, we found significant correlations between measures of visual attention, executive functions and the right frontal lobe region. The presence of widespread blood flow reduction was observed mainly in the frontal lobes of dementia-free patients with advanced PD. Furthermore, performance on specific cognitive measures was highly related to perfusion brain SPECT findings. (orig.)

  16. Changes of rCBF on major depressed patients following TMS treatment: and SPM analysis

    International Nuclear Information System (INIS)

    Zheng, X.M.

    2000-01-01

    Full text: Changes of regional Cerebral Blood Flow (rCBF) on five drug-resistant depressed patients were examined by Single Photon Emission Computed Tomography (SPECT) with 99 Tc m - Hexamethylpropyleneamine Oxime ( 99 Tc m HMPAO) before and after Transcranial Magnetic Stimulation (TMS). The SPECT images were analysed by Statistical Parametric Mapping (SPM) package. TMS at the left Dorsolateral Prefrontal Cortex (DLPFC) of the depressed patients resulted in an increase of rCBF at a focal region in the vicinity of the stimulation site. No change was observed at any remote region. A 34.8% global CBF reduction for the depressed patients was found in their raw data. SPM analysis of the globally scaled images shows that there are increases of rCBF in the parietal region for the depressed patients. Global CBF scaling might contribute to these increases. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections

    Energy Technology Data Exchange (ETDEWEB)

    Erba, P.A. [University of Pisa, and University Hospital of Pisa, Regional Center of Nuclear Medicine, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); University of Pisa, Regional Center of Nuclear Medicine, Pisa (Italy); Leo, G. [ASL Lecce, U.O. Gestione Rapporti Convenzionali, U.O. Chirurgia Generale, Lecce, Pisa (Italy); University of Pisa, and University Hospital of Pisa, Division of Vascular Surgery, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); Sollini, M. [Az. Osp. S.Maria Nuova - IRCCS Reggio Emilia, Nuclear Medicine Unit, Department of Oncology and Advanced Technology, Reggio Emilia (Italy); Tascini, C.; Menichetti, F. [University Hospital of Pisa, Division of Infectious Diseases, Pisa (Italy); Boni, R.; Lazzeri, E.; Mariani, G. [University of Pisa, and University Hospital of Pisa, Regional Center of Nuclear Medicine, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); Berchiolli, R.N.; Ferrari, M. [University of Pisa, and University Hospital of Pisa, Division of Vascular Surgery, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy)

    2014-02-15

    In this study we evaluated the diagnostic performance of {sup 99m}Tc-HMPAO-leucocyte ({sup 99m}Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. {sup 99m}Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37 % of patients (sensitivity and specificity 100 %, versus 85.1 % and 62.5 % for stand-alone SPECT). Sensitivity and specificity were 34 % and 75 % for US, 48.9 % and 83.3 % for CT, and 68.1 % and 62.5 % for the FitzGerald classification. Perioperative mortality was 5.5 %, mid-term mortality 12 %, and long-term mortality 27 %. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61 % versus 63 %, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3 % versus 45.5 %). {sup 99m}Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI

  18. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections.

    Science.gov (United States)

    Erba, P A; Leo, G; Sollini, M; Tascini, C; Boni, R; Berchiolli, R N; Menichetti, F; Ferrari, M; Lazzeri, E; Mariani, G

    2014-02-01

    In this study we evaluated the diagnostic performance of (99m)Tc-HMPAO-leucocyte ((99m)Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. (99m)Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37% of patients (sensitivity and specificity 100 %, versus 85.1% and 62.5% for stand-alone SPECT). Sensitivity and specificity were 34% and 75% for US, 48.9% and 83.3% for CT, and 68.1% and 62.5% for the FitzGerald classification. Perioperative mortality was 5.5%, mid-term mortality 12%, and long-term mortality 27%. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61% versus 63%, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3% versus 45.5%). (99m)Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive

  19. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections

    International Nuclear Information System (INIS)

    Erba, P.A.; Leo, G.; Sollini, M.; Tascini, C.; Menichetti, F.; Boni, R.; Lazzeri, E.; Mariani, G.; Berchiolli, R.N.; Ferrari, M.

    2014-01-01

    In this study we evaluated the diagnostic performance of 99m Tc-HMPAO-leucocyte ( 99m Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. 99m Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37 % of patients (sensitivity and specificity 100 %, versus 85.1 % and 62.5 % for stand-alone SPECT). Sensitivity and specificity were 34 % and 75 % for US, 48.9 % and 83.3 % for CT, and 68.1 % and 62.5 % for the FitzGerald classification. Perioperative mortality was 5.5 %, mid-term mortality 12 %, and long-term mortality 27 %. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61 % versus 63 %, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3 % versus 45.5 %). 99m Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive

  20. Brain perfusion SPECT with Brodmann areas analysis in differentiating frontotemporal dementia subtypes.

    Science.gov (United States)

    Valotassiou, Varvara; Papatriantafyllou, John; Sifakis, Nikolaos; Tzavara, Chara; Tsougos, Ioannis; Psimadas, Dimitrios; Kapsalaki, Eftychia; Fezoulidis, Ioannis; Hadjigeorgiou, George; Georgoulias, Panagiotis

    2014-01-01

    Despite the known validity of clinical diagnostic criteria, significant overlap of clinical symptoms between Frontotemporal dementia (FTD) subtypes exists in several cases, resulting in great uncertainty of the diagnostic boundaries. We evaluated the perfusion between FTD subtypes using brain perfusion (99m)Tc-HMPAO SPECT with Brodmann areas (BA) mapping. NeuroGam software was applied on single photon emission computed tomographic (SPECT) studies for the semi-quantitative evaluation of perfusion in BA and the comparison with the software's normal database. We studied 91 consecutive FTD patients: 21 with behavioural variants (bvFTD), 39 with language variants (lvFTD) [12 with progressive non-fluent aphasia (PNFA), 27 with semantic dementia (SD)], and 31 patients with progressive supranuclear palsy (PSP)/corticobasal degeneration (CBD). Stepwise logistic regression analyses showed that the BA 28L and 32R could independently differentiate bvFTD from lvFTD, while the BA 8R and 25R could discriminate bvFTD from SD and PNFA, respectively. Additionally, BA 7R and 32R were found to discriminate bvFTD from CBD/PSP. The only BA that could differentiate SD from PNFA was 6L. BA 6R and 20L were found to independently differentiate CBD/PSP from lvFTD. Moreover, BA 20L and 22R could discriminate CBD/PSP from PNFA, while BA 6R, 20L and 45R were found to independently discriminate CBD/PSP from SD. Brain perfusion SPECT with BA mapping can be a useful additional tool in differentiating FTD variants by improving the definition of brain areas that are specifically implicated, resulting in a more accurate differential diagnosis in atypical or uncertain forms of FTD.

  1. SPECT in Focal Epilepsies

    Directory of Open Access Journals (Sweden)

    Roderick Duncan

    2000-01-01

    Full Text Available Brain perfusion changes during seizures were first observed in the 1930s. Single Photon Emission Computed Tomography (SPECT was developed in the 1970s, and tracers suitable for the imaging of regional cerebral perfusion (rCP became available in the 1980s. The method was first used to study rCP in the interictal phase, and this showed areas of low perfusion in a proportion of cases, mainly in patients with temporal lobe epilepsies. However, the trapping paradigm of tracers such as hexamethyl propyleneamine oxime (HMPAO provided a practicable method of studying changes in rCP during seizures, and a literature was established in the late 1980s and early 1990s showing a typical sequence of changes during and after seizures of mesial temporal lobe origin; the ictal phase was associated with large increases in perfusion throughout the temporal lobe, with first the lateral, then the mesial temporal lobe becoming hypoperfused in the postictal phase. Activation and inhibition of other structures, such as the basal ganglia and frontal cortex, were also seen. Studies of seizures originating elsewhere in the brain have shown a variety of patterns of change, according to the structures involved. These changes have been used practically to aid the process of localisation of the epileptogenic zone so that epilepsy surgery can be planned.

  2. Functional regional cerebral blood flow SPECT using 99mTc-HM-PAO by speech memory tasks

    International Nuclear Information System (INIS)

    Tohyama, Junko

    1993-01-01

    Using single photon emission computed tomography (SPECT) with Tc-99m HA-PAO, changes in regional cerebral blood flow (rCBF) by giving word memory and Miyake's tasks were determined for localizatin of speech memory function. Twice injection method of Tc-99m HM-PAO was used to obtain subtraction SPECT images; and positioning of the 1st and 2nd SPECT was determined by phantom study. To prevent artifacts and changes in rCBF as far as possible, the subjects were informed word fluency and Miyake's tasks sufficiently. When giving word fluency approach, an increase in rCBF was observed in both the operculum and the supratemporal convolution of dominant hemisphere. When giving Miyake's approach, it was observed predominantly in the supratemporal convolution of dominant hemisphere. Although it was also observed in the base of frontal lobe and operculum, there was no bilateral difference. An increased rCBF in the basal nucleus was more clearly observed by Miyake's than word fluency tasks without bilateral differences. There was no definitive increase in rCBF in the Papez's circuit responsible for memory and emotion by either word fluency or Miyake's tasks. In mentally mild disorder patients, an increased rCBF was observed in the same areas as those in normal subjects. In such patients having a decreased rCBF at rest, an increased rCBF was seen in the contralateral hemisphere and the surrounding areas of the lesions, suggesting compensatory mechanism. (N.K.) 65 refs

  3. A comparison between dopamine transporters imaging and perfusion SPECT with HMPAO-99mTc in the diagnosis of dementia with Lewy bodies

    International Nuclear Information System (INIS)

    Voitota, J.B.; Emptaz, A.; Szurhaj, W.; Steinling, M.; Bombois, St.; Pasquier, F.

    2007-01-01

    Scintigraphic imaging of dementia relies today essentially on the study of brain single photo emission computed tomography (SPECT) perfusion, after intravenous injection of 99m Tc radiopharmaceutical. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear medicine (http:// eanm.org). Dementia with Lewy bodies is the second cause of degenerative dementia. Differential diagnosis may be difficult, in spite of the emergence of standardized diagnostic criteria. Tomo-scintigraphy using iodine 123-labelled FP-CIT (DaTSCAN) could play a role in this process. Cerebral perfusion SPECT imaging is an important step of demented patient evaluation. We compared the diagnostic performance of both of these procedures in the diagnosis of dementia with Lewy bodies. We studied 15 patients; ten DaTSCAN and 14 cerebral perfusion studies were performed. Clinical diagnosis at the end of follow-up was established as the diagnostic reference. Cerebral perfusion SPECT showed a very low sensitivity (20%) and a good specificity (89%); considering a prevalence of dementia with Lewy bodies of 20%, positive predictive value (PPV) was 31% and negative predictive value (NPV) 82%. Performances of DaTSCAN tomo-scintigraphy were more encouraging, (sensitivity and specificity of 100%); predictive values are both of 100%. As a conclusion, DaTSCAN tomo-scintigraphy performs better than cerebral perfusion SPECT in the diagnosis of dementia with Lewy bodies and no conjoint or sequential use of those tests can be recommended. (authors)

  4. 99Tcsup(m)-HMPAO labelled leucocytes: comparison with 111In-tropolonate labelled granulocytes

    International Nuclear Information System (INIS)

    Peters, A.M.; Roddie, M.E.; Zacharopoulos, G.P.; George, P.; Stuttle, A.W.J.; Lavender, J.P.; Danpure, H.J.; Osman, S.

    1988-01-01

    The lipophilic complex, 99 Tcsup(m)-hexamethylpropyleneamine oxime (HMPAO) is an efficient leucocyte label, and labels granulocytes with more stability than mononuclear leucocytes. The recovery of 99 Tcsup(m)-HMPAO granulocytes was similar to 111 In-labelled granulocytes isolated and labelled in plasma using tropolone. The Tsub(1/2) of 99 Tcsup(m)-HMPAO labelled granulocytes in blood was less than that of 111 In-labelled granulocytes. The initial biodistribution of 99 Tcsup(m)-labelled leucocytes was similar to 111 In-labelled granulocytes, with a rapid initial lung transit, prominent splenic activity, bone marrow activity and minimal hepatic activity, although, unlike 111 In, 99 Tcsup(m) activity was also seen in urine, occasionally in the gallbladder, and, from about 4 h, consistently in the colon. Bone marrow activity was particularly prominent with 99 Tcsup(m). About 6% of 99 Tcsup(m) was excreted in the faeces up to 48 h after injection, and about 17% in urine up to 24 h. The time-activity curves of reticuloendothelial activity up to 24 h were broadly similar for the two labelled cell preparations. Clinical information given by the two agents was similar in 27 of 30 patients who received both. We conclude that with respect to granulocyte kinetics and clinical data, 99 Tcsup(m)-HMPAO labelled leucocytes are comparable with 111 In-tropolonate labelled granulocytes. (author)

  5. 99mTc-Hexamethyl Propyleneamine Oxime Brain Perfusion Single Photon Emission Computed Tomography in Characterization of Dementia: An Initial Experience in Indian Clinical Practice

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Sinha, Gaurav Kumar; Neogi, Rajarshi; Thukral, Ramesh Kumar

    2014-01-01

    There is a growing health burden in developing countries due to recent trends of increasing incidence of neurodegenerative diseases. To reduce the healthcare cost and effective management of dementia illness, early diagnosis, accurate differentiation and their progression assessment is becoming crucially important. We are utilizing 99m Tc-d, l-hexamethyl propyleneamine oxime (HMPAO) brain perfusion single photon emission computed tomography (SPECT) to characterize dementia on the basis of perfusion patterns and observed significant improvement in their management. Eleven patients (median age of 60 years range of 53-83 years) with clinical suspicion of dementia underwent 99m Tc-HMPAO brain perfusion SPECT. SPECT-computed tomography acquisition done, data are reconstructed, reviewed in three view and further processed in “neurogam” to get voxel based analysis and the comparison with age based normal database and surface mapping. Final diagnosis was done with clinical correlation. Four patients are diagnosed as Alzheimer's disease, two as frontotemporal dementia, one as dementia of Lewy bodies, two as vascular dementia and two as pseudodementia. All imaging findings are well-correlated with clinical background. Brain perfusion SPECT with HMPAO was very helpful to us in characterizing the patients of dementia by its perfusion pattern

  6. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    International Nuclear Information System (INIS)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S.

    2003-01-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus

  7. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S. [College of Medicine, Univ. of Inhwa, Incheon (Korea, Republic of)

    2003-07-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus.

  8. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual 201 Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of the coronary reserves

    International Nuclear Information System (INIS)

    Mendoza V, R.

    2004-01-01

    The objective of this work was to determine if the images of SPECT 201 TI in rest of 15 minutes, 24 late hours and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of 201 TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT 201 TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of 201 TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  9. Perfusion MRI before and after acetazolamide administration for assessment of cerebrovascular reserve capacity in patients with symptomatic internal carotid artery (ICA) occlusion: comparison with {sup 99m}Tc-ECD SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ma, J.; Holtmannspoetter, M.; Brueckmann, H. [University of Munich, Department of Neuroradiology, Klinikum Grosshadern, Munich (Germany); Mehrkens, J.H.; Schmid-Elsaesser, R. [University of Munich, Department of Neurosurgery, Klinikum Grosshadern, Munich (Germany); Linke, R. [University of Munich, Department of Nuclear Medicine, Klinikum Grosshadern, Munich (Germany); Steiger, H.J. [Heinrich-Heine University, Department of Neurosurgery, Duesseldorf (Germany); Bruening, R. [University of Munich, Department of Neuroradiology, Klinikum Grosshadern, Munich (Germany); Asklepios Klinik Barmbek, Department of Radiology, Hamburg (Germany)

    2007-04-15

    Impaired cerebral vascular reserve (CVR) in patients with symptomatic internal carotid artery (ICA) occlusion is regarded as a possible indication for performing extra-/intracranial (EC/IC) bypass surgery. As perfusion MR imaging (MRI) can demonstrate cerebral haemodynamics at capillary level, our hypothesis was that perfusion MRI could be used in these patients for the evaluation of CVR following acetazolamide challenge in a similar way to single photon emission CT (SPECT) and might provide additional information. Enrolled in the study were 12 patients (mean age 61.3 years; 11 male, 1 female) with symptomatic unilateral ICA occlusion proven by angiography. Both perfusion MRI and 99m-technetium-ethyl-cysteinate dimer ({sup 99m}Tc-ECD) SPECT were performed before and after injection of acetazolamide (Diamox,1000 mg i.v.). CVR parameters including regional cerebral blood flow (rCBF) and volume (rCBV), and mean transit times (MTT) were measured by perfusion MRI. The patients with impaired CVR proven by SPECT (n = 9) had a negative mean rCBF increment (-46.52%), negative rCBV increment (-13.5%) and delayed MTT (mean +2.98 s), respectively, on the occluded side (Student's t-test all P < 0.05). The patients with sufficient CVR (n = 3) had a mean rCBF increment of 1.2%, a decrement of rCBV of 10.46%, and a mean MTT shortening of 0.27 s following the acetazolamide injection. Perfusion MRI before and after acetazolamide administration compares favourably with {sup 99m}Tc-ECD SPECT for the detection of impaired CVR. The impact that perfusion MRI studies (before and after acetazolamide administration) might have on the treatment decision in patients with ICA occlusion has yet to be determined by a prospective study. (orig.)

  10. Radiolabelling of sperm cells with 99mTc-HMPAO. In vivo visualization of sperm cell migration in rabbits

    International Nuclear Information System (INIS)

    Bockisch, A.; Tennessee Univ., Knoxville, TN; Tennessee Univ., Knoxville, TN; Al-Hasani, S.; Ven, H.V.D.; Diedrich, K.; Krebs, D.; Posch, C.; Hotze, A.; Biersack, H.J.

    1989-01-01

    The present paper is the first descriptive radiolabeling of sperm cells in order to visualize their in vivo migration and imaging by scintigraphic technique, 99m Tc-HMPAO was used which combines favourable characteristics of both imaging modalities and radiation exposure. The radiolabeling yield was optimised for human sperm cells, and was increasing with the number of sperm cells, the amount of HMPAO, the 99m Tc-HMPAO concentration and the duration of the incubation. Incubation periods greater than 20 min, however, resulted only in a minor increase of labeling yield. A delay of more than 5 min between the labeling of the HMPAO with 99m Tc and initiation of the incubation of the sperm cells with the 99m Tc-HMPAO also decreased the maximum labeling yield. The radiolabeled cells were found to be stable and after 18 h > 93% of the activity was still bound to the sperm cells. After insemination of labeled sperm cells in ovulating rabbits the accumulation of the cells in the Fallopian tubes and their subsequent migration could be clearly visualized by scintigraphic techniques in vivo. (orig.) [de

  11. Motor cortex stimulation(MCS) for intractable complex regional pain syndrome (CRPS) type II: PSM analysis of Tc-99m ECD brain perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. A.; Son, B. C.; Yoo, I. R.; Kim, S. H.; Kim, E. N.; Park, Y. H.; Lee, S. Y.; Sohn, H. S.; Chung, S. K. [College of Medicine, The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2001-07-01

    We had experienced a patient with intractable CRPS in whom statistical parametric mapping (SPM) analysis of cerebral perfusion explained the mechanism of pain control by MCS. A 43-year-old man presented spontaneous severe burning pain in his left hand and forearm and allodynia over the left arm and left hemibody. After the electrodes for neuromodulation therapy were inserted in the central sulcus, the baseline and stimulation brain perfusion SPECT using Tc-99m ECD were obtained within two days. The differences between the baseline and stimulation SPECT images, estimated at every voxel using t-statistics using SPM-99 software, were considered significant at a threshold of uncorrected P values less than 0.01. Among several areas significantly activated following pain relief with MCS, ipsilateral pyramidal tract in the cerebral peduncle might be related to the mechanism of pain control with MCS through efferent motor pathway. The result suggested that corticospinal neurons themselves or motor cortex efferent pathway maintained by the presence of intact corticospinal neurons could play an important role in producing pain control after MCS. This study would helpful in understanding of neurophysiology.

  12. Motor cortex stimulation(MCS) for intractable complex regional pain syndrome (CRPS) type II: PSM analysis of Tc-99m ECD brain perfusion SPECT

    International Nuclear Information System (INIS)

    Chung, Y. A.; Son, B. C.; Yoo, I. R.; Kim, S. H.; Kim, E. N.; Park, Y. H.; Lee, S. Y.; Sohn, H. S.; Chung, S. K.

    2001-01-01

    We had experienced a patient with intractable CRPS in whom statistical parametric mapping (SPM) analysis of cerebral perfusion explained the mechanism of pain control by MCS. A 43-year-old man presented spontaneous severe burning pain in his left hand and forearm and allodynia over the left arm and left hemibody. After the electrodes for neuromodulation therapy were inserted in the central sulcus, the baseline and stimulation brain perfusion SPECT using Tc-99m ECD were obtained within two days. The differences between the baseline and stimulation SPECT images, estimated at every voxel using t-statistics using SPM-99 software, were considered significant at a threshold of uncorrected P values less than 0.01. Among several areas significantly activated following pain relief with MCS, ipsilateral pyramidal tract in the cerebral peduncle might be related to the mechanism of pain control with MCS through efferent motor pathway. The result suggested that corticospinal neurons themselves or motor cortex efferent pathway maintained by the presence of intact corticospinal neurons could play an important role in producing pain control after MCS. This study would helpful in understanding of neurophysiology

  13. Vfa1 Binds to the N-terminal Microtubule-interacting and Trafficking (MIT) Domain of Vps4 and Stimulates Its ATPase Activity*

    Science.gov (United States)

    Vild, Cody J.; Xu, Zhaohui

    2014-01-01

    The endosomal sorting complexes required for transport (ESCRT) are responsible for multivesicular body biogenesis, membrane abscission during cytokinesis, and retroviral budding. They function as transiently assembled molecular complexes on the membrane, and their disassembly requires the action of the AAA-ATPase Vps4. Vps4 is regulated by a multitude of ESCRT and ESCRT-related proteins. Binding of these proteins to Vps4 is often mediated via the microtubule-interacting and trafficking (MIT) domain of Vps4. Recently, a new Vps4-binding protein Vfa1 was identified in a yeast genetic screen, where overexpression of Vfa1 caused defects in vacuolar morphology. However, the function of Vfa1 and its role in vacuolar biology were largely unknown. Here, we provide the first detailed biochemical and biophysical study of Vps4-Vfa1 interaction. The MIT domain of Vps4 binds to the C-terminal 17 residues of Vfa1. This interaction is of high affinity and greatly stimulates the ATPase activity of Vps4. The crystal structure of the Vps4-Vfa1 complex shows that Vfa1 adopts a canonical MIT-interacting motif 2 structure that has been observed previously in other Vps4-ESCRT interactions. These findings suggest that Vfa1 is a novel positive regulator of Vps4 function. PMID:24567329

  14. Vfa1 binds to the N-terminal microtubule-interacting and trafficking (MIT) domain of Vps4 and stimulates its ATPase activity.

    Science.gov (United States)

    Vild, Cody J; Xu, Zhaohui

    2014-04-11

    The endosomal sorting complexes required for transport (ESCRT) are responsible for multivesicular body biogenesis, membrane abscission during cytokinesis, and retroviral budding. They function as transiently assembled molecular complexes on the membrane, and their disassembly requires the action of the AAA-ATPase Vps4. Vps4 is regulated by a multitude of ESCRT and ESCRT-related proteins. Binding of these proteins to Vps4 is often mediated via the microtubule-interacting and trafficking (MIT) domain of Vps4. Recently, a new Vps4-binding protein Vfa1 was identified in a yeast genetic screen, where overexpression of Vfa1 caused defects in vacuolar morphology. However, the function of Vfa1 and its role in vacuolar biology were largely unknown. Here, we provide the first detailed biochemical and biophysical study of Vps4-Vfa1 interaction. The MIT domain of Vps4 binds to the C-terminal 17 residues of Vfa1. This interaction is of high affinity and greatly stimulates the ATPase activity of Vps4. The crystal structure of the Vps4-Vfa1 complex shows that Vfa1 adopts a canonical MIT-interacting motif 2 structure that has been observed previously in other Vps4-ESCRT interactions. These findings suggest that Vfa1 is a novel positive regulator of Vps4 function.

  15. Potential value of serial cerebral SPECT scanning in the evaluation of psychiatric illness

    International Nuclear Information System (INIS)

    Notardonato, H.; Gonzalez-Avilez, A.; Van Heertum, R.L.; O'Connell, R.A.; Yudd, A.P.

    1989-01-01

    Cerebral SPECT imaging has the potential to make an important contribution to clinical psychiatry. Cerebral SPECT scanning, stimulated by the work with PET, is readily available and much less expensive than PET. This paper reports a case demonstrating the potential value of cerebral SPECT scanning with I-123 IMP, specifically in the serial evaluation of a schizophrenic patient with auditory hallucinations. The initial scan revealed focal areas of increased uptake in the caudate nuclei of the basal ganglia, and in the right temporal lobe. After pharmacological treatment with clinical improvement, the follow-up SPECT scan demonstrated significant improvement in the distribution of the radiopharmaceutical

  16. Technetium-99m HMPAO labeled leukocytes in inflammation imaging

    International Nuclear Information System (INIS)

    Uno, Kimiichi; Yoshikawa, Kyousan; Imazeki, Keiko; Minoshima, Satoshi; Arimizu, Noboru

    1991-01-01

    Technetium-99m-HMPAO (Tc-99m-HMPAO) labeled leukocyte imaging was carried out in 19 patients at 3-5 hr after reinjection. There were no side effects noted. Tc-99m leukocyte images showed gall bladder, colon, kidney, and urinary bladder activity in normal distribution as a result of excretion of the eluted Tc-99m complex. They yielded a sensitivity of 93%, a specificity of 100% and an accuracy of 95%. They were correctly positive in 14 out of 19 cases. But one false negative case was seen in a patient with pyonephrosis showing a lack of renal function with decreased renal blood flow. It was concluded that they have some advantages over In-111 leukocyte images, but we have to consider the fact that the ureteral obstruction or the lack of renal function with decreased renal blood flow may result in a false positive or a false negative case. (author)

  17. The origins of SPECT and SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Brian F. [University College London, Institute of Nuclear Medicine, London (United Kingdom); University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)

    2014-05-15

    Single photon emission computed tomography (SPECT) has a long history of development since its initial demonstration by Kuhl and Edwards in 1963. Although clinical utility has been dominated by the rotating gamma camera, there have been many technological innovations with the recent popularity of organ-specific dedicated SPECT systems. The combination of SPECT and CT evolved from early transmission techniques used for attenuation correction with the initial commercial systems predating the release of PET/CT. The development and acceptance of SPECT/CT has been relatively slow with continuing debate as to what cost/performance ratio is justified. Increasingly, fully diagnostic CT is combined with SPECT so as to facilitate optimal clinical utility. (orig.)

  18. Evaluation of leucocytes labelling technique with 99m Tc - HMPAO

    International Nuclear Information System (INIS)

    Moraes, D.W.; Marinho, N.S.; Rezende, M.E.X.; Buchpiguel, C.A.; Rockmann, T.M.B.

    1992-01-01

    An evaluation of the leukocytes labelling technique with HMPAO- 99m Tc, using low volume of blood and keeping the labelling efficiency and cellular viability in compatible levels with those preconized by the literature is presented. (C.G.C.)

  19. Physical and subjective evaluation of a three-detector (TRIAD 88) SPECT system

    International Nuclear Information System (INIS)

    D'Souza, M.F.; Mumma, C.G.; Allen, E.W.; Phal, J.J.; Prince, J.R.

    1995-01-01

    The three-detector TRIAD 88 is a variable cylindrical FOV whole-body SPECT system designed for both brain as well as body organ imaging. The system performance was assessed in terms of physical indices and clinical quality. Measures of low contrast resolution using contrast-detail curves, high contrast resolution using LSFs and associated frequency descriptors, display characteristics, system sensitivity, energy resolution and uniformity analysis were utilized. In addition, images of Carlson phantom, Hoffman brain phantom and clinical brain images were used to compare two collimators subjectively. Measurements and calculations were obtained for two sets of parallel hole collimators, i.e., LEUR P AR and LEHR P AR. Of special interest is the consistency among the three detectors. The planar and volume sensitivities for the LEUR P AR collimator were about 58% of those of the LEHR P AR collimator. The planar spatial resolution of the two collimators differed by about 14%. The display was characterized by a logistic model H and D curve. The planar contrast-detail curves demonstrated no statistical difference in lesion detectability between the two collimator types, however SPECT phantom and clinical images demonstrated improved performance with the LEUR P AR collimator. Images of Hoffman single slice brain and Carlson phantoms and Tc-99m (HMPAO) brain images demonstrated excellent image quality. There was similarity in performance parameters of the three detector heads. 49 refs., 6 tabs., 8 figs

  20. Investigation of olfactory function in normal volunteers and patients with anosmia : analysis of brain perfusion SPECTs using statistical parametric mapping

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Y. A.; Kim, S. H.; Sohn, H. S.; Chung, S. K. [Catholic University College of Medicine, Seoul (Korea, Republic of)

    2002-07-01

    The purpose of this study was to investigate olfactory function with Tc-99m ECD brain perfusion SPECT using statistical parametric mapping (SPM) analysis in normal volunteers and patients with anosmia. The study populations were 8 subjects matched healthy volunteers and 16 subjects matched patients with anosmia. We obtaibed baseline and post-stimulation (3% butanol) brain perfusion SPECTs in the silent dark room. We analyzed the all SPECTs using SPM. The difference between two sets of brain perfusion SPECTs were compared with t-test. The voxels with p-value of less than 0.01 were considered to be significantly different. We demonstrated increased perfusion in the both cingulated gyri, right middle temporal gyrus, right superior and inferior frontal gyri, right lingual gyrus and right fusiform gyrus on post-stimulation brain SPECT in normal volunteers, and demonstrated decreased perfusion in the both cingulate gyri, right middle temporal gyrus, right rectal gyrus and both superior and inferior frontal gyri in the 10 patients with anosmia. No significant hypoperfusion area was observed in the other 6 patients with anosmia. The baseline and post-stimulation brain perfusion SPECTs can helpful in the evaluation of olfactory function and be useful in the diagnosis of anosmia.

  1. Investigation of olfactory function in normal volunteers and patients with anosmia : analysis of brain perfusion SPECTs using statistical parametric mapping

    International Nuclear Information System (INIS)

    Chung, Y. A.; Kim, S. H.; Sohn, H. S.; Chung, S. K.

    2002-01-01

    The purpose of this study was to investigate olfactory function with Tc-99m ECD brain perfusion SPECT using statistical parametric mapping (SPM) analysis in normal volunteers and patients with anosmia. The study populations were 8 subjects matched healthy volunteers and 16 subjects matched patients with anosmia. We obtaibed baseline and post-stimulation (3% butanol) brain perfusion SPECTs in the silent dark room. We analyzed the all SPECTs using SPM. The difference between two sets of brain perfusion SPECTs were compared with t-test. The voxels with p-value of less than 0.01 were considered to be significantly different. We demonstrated increased perfusion in the both cingulated gyri, right middle temporal gyrus, right superior and inferior frontal gyri, right lingual gyrus and right fusiform gyrus on post-stimulation brain SPECT in normal volunteers, and demonstrated decreased perfusion in the both cingulate gyri, right middle temporal gyrus, right rectal gyrus and both superior and inferior frontal gyri in the 10 patients with anosmia. No significant hypoperfusion area was observed in the other 6 patients with anosmia. The baseline and post-stimulation brain perfusion SPECTs can helpful in the evaluation of olfactory function and be useful in the diagnosis of anosmia

  2. Regional Distribution of Cerebral Blood Flow in childhood Measured by '99mTc-HMPAO SPECT: Reference Values of Semiquantitative Indices and Effect of Age

    International Nuclear Information System (INIS)

    Kim, Sang Eun; Lee, Dong Soo; Chung, June Key

    1991-01-01

    Regional cerebral blood flow (rCBF) was evaluated in 12 children ranging in age from 2.7 to 10.0 yr using 99m Tc-HMPAO SPECT. For quantitative analysis, 13 pairs of homologous regions of interest (ROIs) were created on three attenuation-corrected 18,8 mm thick transverse slices matching the cerebral cortical regions, deep gray matter, cerebellar hemisphere, and vascular territories, and the semiquantitative indices including 'right to left ratio [(mean count/voxel of homologous right ROI) /(mean count/voxel of homologous left ROI)] and regional index '(RI) [(mean count/voxel of a ROI)/(mean count/voxel of all ROIs of each hemisphere)] were calculated. Mean values of right to left ratios of homologous regions ranged from 0.984 to 1.028 in children under 5 yr (group 1) and from 0.982 to 1.012 in children between 5 and 10 yr (group 2), and the mean value ±2 S.D. for each region did not exceed 11%. and 12% in group 1 and group 2, respective]y. There were no statistically significant differences between the RIs of the homologous right and left regions. Significant differences of RIs were found both between vascular regions (p<0,0005 for group 1, and p=0,0001 for group 2) and between regions of cerebral cortices (p<0,0005 for group 1, and p<0,005 for group 2) with a relatively high value in the occipital cortex and the lower values in the cerebellum and deep gray matter among the regions of cerebral cortices in both groups. There were no significant differences between the Rls of corresponding regions of group 1 and group 2, except a significantly higher value of right deep gray matter in group 2 than in group 1 (p=0.0301). The RIs of the superior frontal cortex and deep gray matter showed to be positively correlated with age (superior frontal cortex; right: rs=0.5254, p=0.0814, left: rs=0.5919, p=0.0496/deep gray matter; right: rs=0.8246, p=0.0062, left: rs=0.6266, p=0,0377). The results suggest that the rCBF pattern of children approaches that of adults in an occipito

  3. Different uptake of 99mTc-ECD adn 99mTc-HMPAO in the same brains: analysis by statistical parametric mapping.

    Science.gov (United States)

    Hyun, Y; Lee, J S; Rha, J H; Lee, I K; Ha, C K; Lee, D S

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer (99mTc-ECD) and technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62+/-12 years) using 99mTc-ECD and 99mTc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for 99mTc-ECD and 99mTc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the 99mTc-ECD and 99mTc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either 99mTc-ECD or 99mTc-HMPAO SPET images. SPM analysis revealed significantly different uptake of 99mTc-ECD and 99mTc-HMPAO in the same brains. On the 99mTc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the 99mTc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with 99mTc-ECD and 99mTc-HMPAO.

  4. Neuropsychological functions and rCBF SPECT in Parkinson's disease patients considered candidates for deep brain stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Paschali, Anna; Lakiotis, Velissarios; Vassilakos, Paulos [University of Patras Medical School, Department of Nuclear Medicine, Patras (Greece); Messinis, Lambros; Lyros, Epameinondas; Papathanasopoulos, Panagiotis [University of Patras Medical School, Department of Neurology, Neuropsychology Section, Patras (Greece); Constantoyannis, Costas; Kefalopoulou, Zinovia [University of Patras Medical School, Department of Neurosurgery, Patras (Greece)

    2009-11-15

    In the present study, we examined relationships between neuropsychological functions and brain single photon emission computed tomography (SPECT) regional cerebral blood flow (rCBF) observed at presurgical evaluation for deep brain stimulation (DBS) of the subthalamic nucleus (STN) in advanced Parkinson's disease (PD) patients. Twenty advanced non-demented PD patients, candidates for DBS surgery, underwent perfusion brain SPECT study and neuropsychological assessment prior to surgery (range: 30-50 days). Patients were further assessed using the Unified Parkinson's Disease Rating Scale (UPDRS) and Hoehn and Yahr (H and Y) scale. During all assessments patients were ''on'' standard medication. NeuroGam software, which permits voxel by voxel analysis, was used to compare the brain perfusion of PD patients with a normal database adjusted for sex and age. Neuropsychological scores were compared to age, education and sex-adjusted normative databases. Our results indicated that the distribution of rCBF showed significant differences when compared to an age- and sex-adjusted normative database. We found impaired blood flow in 17 (85%) of our patients in the left prefrontal lobe, in 14 (70%) in the right prefrontal lobe and in 11 (55%) in the left frontal and right parietal lobes. Neuropsychological testing revealed that 18 (90%) of our patients had significant impairments in measures of executive functions (set-shifting) and 15 (75%) in response inhibition. Furthermore, we found significant correlations between measures of visual attention, executive functions and the right frontal lobe region. The presence of widespread blood flow reduction was observed mainly in the frontal lobes of dementia-free patients with advanced PD. Furthermore, performance on specific cognitive measures was highly related to perfusion brain SPECT findings. (orig.)

  5. Diagnosis of pyogenic pelvic inflammatory diseases by {sup 99m}Tc-HMPAO leucocyte scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Rachinsky, I.; Boguslavsky, L.; Golan, H.; Lantsberg, S. [Department of Nuclear Medicine, Ben-Gurion Univ. of the Negev (Israel); Goldstein, D.; Pak, I.; Katz, M. [Department of Obstetrics and Gynecology, Ben-Gurion Univ. of the Negev, Beer-Sheva (Israel)

    2000-12-01

    Pelvic inflammatory disease (PID) is one of the major health problems of women of child-bearing age. Among the most serious complications of PID is the formation of a tubo-ovarian abscess (TOA). Early diagnosis of this condition may prevent serious surgical complications such as peritonitis and sepsis, which may be fatal. The purpose of this study was to investigate the efficacy of technetium-99m hexamethylpropylene amine oxime (HMPAO) leucocyte scintigraphy in the diagnosis of TOA. Twenty women with high clinical suspicion of TOA underwent {sup 99m}Tc-HMPAO leucocyte scintigraphy. The labelling of leucocytes with {sup 99m}Tc-HMPAO was performed according to a standard protocol. Scans were obtained at 1, 3 and 24 h following the injection of the labelled leucocytes. In eight cases the early and/or late scan was positive, in 11 cases it was negative, and in one case of ovarian cyst torsion, confirmed by laparoscopy, it showed slight uptake in the capsule of the cyst (false-positive). The sensitivity of {sup 99m}Tc-HMPAO leucocyte scintigraphy was 100%, specificity 91.6%, positive predictive value 89%, negative predictive value 100% and overall accuracy 95%. It is concluded that leucocyte scintigraphy is a non-invasive, safe, physiological and accurate procedure for the diagnosis of TOA. The 24-h scan is crucial, since in some cases the abscess was not clearly visualized on the early scan. Leucocyte scintigraphy may reduce the need for CT, diagnostic laparoscopy and unnecessary invasive surgical procedures. (orig.)

  6. /sup 99/Tcsup(m)-HMPAO labelled leucocytes: comparison with /sup 111/In-tropolonate labelled granulocytes

    Energy Technology Data Exchange (ETDEWEB)

    Peters, A.M.; Roddie, M.E.; Zacharopoulos, G.P.; George, P.; Stuttle, A.W.J.; Lavender, J.P.; Danpure, H.J.; Osman, S.

    1988-06-01

    The lipophilic complex, /sup 99/Tcsup(m)-hexamethylpropyleneamine oxime (HMPAO) is an efficient leucocyte label, and labels granulocytes with more stability than mononuclear leucocytes. The recovery of /sup 99/Tcsup(m)-HMPAO granulocytes was similar to /sup 111/In-labelled granulocytes isolated and labelled in plasma using tropolone. The Tsub(1/2) of /sup 99/Tcsup(m)-HMPAO labelled granulocytes in blood was less than that of /sup 111/In-labelled granulocytes. The initial biodistribution of /sup 99/Tcsup(m)-labelled leucocytes was similar to /sup 111/In-labelled granulocytes, with a rapid initial lung transit, prominent splenic activity, bone marrow activity and minimal hepatic activity, although, unlike /sup 111/In, /sup 99/Tcsup(m) activity was also seen in urine, occasionally in the gallbladder, and, from about 4 h, consistently in the colon. Bone marrow activity was particularly prominent with /sup 99/Tcsup(m). About 6% of /sup 99/Tcsup(m) was excreted in the faeces up to 48 h after injection, and about 17% in urine up to 24 h. The time-activity curves of reticuloendothelial activity up to 24 h were broadly similar for the two labelled cell preparations. Clinical information given by the two agents was similar in 27 of 30 patients who received both. We conclude that with respect to granulocyte kinetics and clinical data, /sup 99/Tcsup(m)-HMPAO labelled leucocytes are comparable with /sup 111/In-tropolonate labelled granulocytes.

  7. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  8. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    2002-01-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  9. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    2002-03-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  10. Regional differences between 99mTc-ECD and 99mTc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2003-01-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether 99m Tc-HMPAO or 99m Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8±6.6 years) were assigned to 99m Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6±6.7 years) to 99m Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq 99m Tc-HMPAO or 99m Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether 99m Tc-HMPAO and 99m Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  11. SPM analysis of cerebrovascular reserve capacity after stimulation with acetazolamide measured by Tc-99m ECD SPECT in normal brain MRI patient

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. H.; Yoon, S. N.; Yoon, J. K.; Cho, C. W. [College of Medicine, Univ. of Ajou, Suwon (Korea, Republic of)

    2003-07-01

    This study was undertaken to evaluate normal response of acetazolamide in normal individuals, whose brain MRI is normal, using SPM99. In total, 10 Tc- 99m ECD brain SPECT were evaluated retrospectively. The half of the patients were male. Their mean age was 47.1 years old with a range of 33-61 years. They all visited our neurology department to evaluate stroke symptom. Their brain MRI was normal. Rest/acetazolamide brain SPECT was perfomed using Tc-99m ECD and the sequential injection and subtraction method. SPECT was acquired using fanbeam collimators and triple-head gamma camera (MultiSPECT III, Siemens medical systems, Inc. Hoffman Estates, III, USA). Chang's attenuation correction was applied their brain SPECT revealed normal rCBF pattern in visual analysis by two nuclear physician and they were diagnosed clinically normal. Using SPM method, we compared rest brain SPECT images with those of acetazolamide brain SPECT and measured the extent of the area with significant perfusion change (P<0.05) in predefined 34 cerebral regions. Acetazolamide brain SPECT showed no significant decreased region in comparison to rest brain SPECT. Only small portion of left mid temporal gyrus revealed increased rCBF on acetazolamide brain SPECT in comparison to rest brain SPECT. It apperas that there is no significant change in rCBF between rest and acetazolamide brain SPECT using Tc-99m ECD. The small number of this study is limitation of our study.

  12. Clinical application of 99mTc-HMPAO labeled leucocytes imaging in detecting bone joint infection

    International Nuclear Information System (INIS)

    Li Biao; Barthe, N.; Basse-Cathalinat, B.

    1995-01-01

    99m Tc-MDP scintigraphy and 99m Tc-HMPAO-leucocytes imaging were performed in twenty five patients with clinically suspected bone joint infection. All of the 25 cases were confirmed by surgery, microbiological and histologic examinations. Among them 21 cases were definitively diagnosed as infections, while 3 cases were non-infection. The results of 99m Tc-MDP scintigraphy showed that all of 25 cases demonstrated anomalous accumulation of radioactivity in the clinically suspected infections sites, while in 99m Tc-HMPAO-leucocytes imaging, concentrated radioactivity in proved infectious sites was observed in 19 cases, non-anomalous radioactivity found in 4 cases of non-infectious sites, but there were 2 cases false negative with long term antibiotics treatment, none of the case was false positive. Thereby a sensitivity of the labelled leucocytes imaging of 90.5%, a specificity of 100%, and a accuracy of about 92% were found. Present research work concluded that 99m Tc-HMPAO labelled leucocytes imaging provided a non-invasive, effective, and reliable diagnostic method in detecting patients with clinically suspected bone joint infection and afforded strong evidence for effective therapy

  13. Relationship between brain perfusion SPECT and MMSE score in dementia of Alzheimer's type: a statistical parametric mapping analysis

    International Nuclear Information System (INIS)

    Kang, Hye Jin; Kang, Eun Joo; Lee, Jae Sung

    2002-01-01

    The aim of this study was to identify the brain areas in which reductions of regional cerebral blood flow (rCBF) were correlated with decline of general mental function, measured by Mini-Mental State Examination (MMSE). Tc-99m HMPAO brain SPECT was performed in 9 probable AD patients at the initial and follow-up periods of 1.8 years (average) after the first study. MMSE scores were also measured in both occasions. The mean MMSE score of the initial study 16.4 (range: 5-24) and the mean MMSE score of the follow-up was 8.1 (range: 0-17). Each SPECT image was normalized to the cerebellar activity and a correlation analysis was performed between the level of rCBF in AD patients and the MMSE scores by voxel-based analysis using SPM99 software. Significant correlation was found between the blood-flow decrease in left inferior prefrontal region(BA 47) and left middle temporal region (BA 21) and the MMSE score changes. Additional areas such as anterior and posterior cingulate cortices, precuneus, and bilateral superior and middle prefrontal regions showed and similar trends. A relationship was found between reduction of regional cerebral blood flow in left prefrontal and temporal areas and decline of cognitive function in Alzheimer's diseases (AD) patients. This voxel-based analysis is useful in evaluating the progress of cognitive function in Alzheimer's disease

  14. Different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains: analysis by statistical parametric mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I.Y. [Dept. of Nuclear Medicine, Inha University College of Medicine, Incheon (Korea); Lee, J.S.; Lee, D.S. [Dept. of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea); Rha, J.H.; Lee, I.K.; Ha, C.K. [Dept. of Neurology, Inha University College of Medicine, Incheon (Korea)

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer ({sup 99m}Tc-ECD) and technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62{+-}12 years) using {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either {sup 99m}Tc-ECD or {sup 99m}Tc-HMPAO SPET images. SPM analysis revealed significantly different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains. On the {sup 99m}Tc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the {sup 99m}Tc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with {sup 99m}Tc-ECD and

  15. [Screening with angiographic images prior to (99m)Tc-HMPAO labelled leukocyte scintigraphy in the diagnosis of periprosthetic infection].

    Science.gov (United States)

    Granados, U; Fuster, D; Soriano, A; García, S; Bori, G; Martínez, J C; Mayoral, M; Perlaza, P; Tomás, X; Pons, F

    2015-01-01

    To evaluate the impact of the angioscintigrapy of the three phase bone scan as screening method to rule out infection of the hip and knee prosthesis prior to performing the (99m)Tc-HMPAO leukocyte scintigraphy. A total of 120 (70 women, 50 men; mean age 71±11years) with clinical suspicion of hip (n=63) or knee (n=57) infection of the prosthesis and clinical suspicion of infection were evaluated prospectively. All patients underwent three-phase bone scan (angioscintigraphy, vascular and bone phase) and (99m)Tc-HMPAO-labelled white blood cell scintigraphy. Final diagnosis of infection was made by microbiological documentation or clinical follow-up for at least 12months. Eighteen out of 120 patients were diagnosed of infection of hip prosthesis (n=10) or knee prosthesis (n=8). The angioscintigraphy was positive in 15/18 infected cases and in 21/102 of the non-infected cases with a sensitivity of 83%, specificity of 79% and negative predictive value of 97%. Sensitivity and specificity of (99m)Tc-HMPAO leukocyte scintigraphy were 72% and 95%, respectively. If the leukocyte labeled scintigraphies had been used exclusively for patients with positive angioscintigraphy, this would have saved up to 70% of the (99m)Tc-HMPAO leukocyte scintigraphies performed. There were no cases of infection with positive labeled leukocyte scintigraphy and negative angioscintigraphy. Angioscintigraphy (blood flow phase of bone scan) is a useful technique for screening for hip and knee joint prosthesis infection, significantly reducing the need for (99m)Tc-HMPAO leukocyte scintigraphy without affecting the sensitivity of the technique. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  16. {sup 18}F-PET imaging: frequency, distribution and appearance of benign lesions; Die Positronenemissionstomographie des Skelettsystems mit {sup 18}FNa: Haeufigkeit, Befundmuster und Verteilung benigner Veraenderungen

    Energy Technology Data Exchange (ETDEWEB)

    Schirrmeister, H.; Kotzerke, J.; Rentschler, M.; Traeger, H.; Fenchel, S.; Diederichs, C.G.; Reske, S.N. [Ulm Univ. (Germany). Abt. Nuklearmedizin; Nuessle, K. [Ulm Univ. (Germany). Abt. fuer Roentgendiagnostik

    1998-09-01

    Purpose: We evaluated the frequency, distribution and appearance of benign lesions in {sup 18}F-PET scans. Methods: Between March 1996 and May 1997, {sup 18}F-PET scans were performed in 59 patients in addition to conventional planar bone scintigraphy. Eleven patients were subjected to additional SPECT imaging. The main indication was searching for bone metastases (58 pat.). The diagnosis was confirmed radiologically. Results: With {sup 18}F-PET in 39 patients (66,1%) 152 benign lesions, mostly located in the spine were detected. {sup 99m}Tc bone scans revealed 45 lesions in 10 patients. Osteoarthritis of the intervertebral articulations (69%) or of the acromioclavicular joint (15%) were the most common reasons for degenerative lesions detected with {sup 18}F-PET. Osteophytes appeared as hot lesions located at two adjacent vertebral endplates. Osteoarthritis of the intervertebral articulations showed an enhanced tracer uptake at these localizations, whereas endplate fractures of the vertebral bodies appeared very typically; solitary fractures of the ribs could not be differentiated from metastases. Rare benign lesions were not studied. Conclusion: Most of the degenerative lesions (84%) detected with {sup 18}F-PET had a very typical appearance and could be detected with the improved spatial resolution and advantages of a tomographic technique. {sup 18}F-PET had an increased accuracy in detecting degenerative bone lesions. (orig.) [Deutsch] Ziel: Wir untersuchten Haeufigkeit und Befundmuster benigner Skelettveraenderungen mit {sup 18}F-PET. Material und Methoden: Zwischen 3/96 und 5/97 untersuchten wir 59 Patienten mit {sup 18}F-PET zusaetzlich zur planaren, bei 11 Patienten durch SPECT ergaenzten konventionellen Skelettszintigraphie (KS). Hauptindikation war die Metastasensuche (58 Pat.). Die Befundkontrolle erfolgte radiologisch. Ergebnisse: {sup 18}F-PET zeigte bei 39 Patienten (66,1%) 152 meist in der Wirbelsaeule lokalisierte, benigne Mehranreicherungen. Mit der

  17. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  18. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  19. Cerebral perfusion inhomogeneities in schizophrenia demonstrated with single photon emission computed tomography and Tc99m-hexamethylpropyleneamineoxim

    International Nuclear Information System (INIS)

    Bajc, M.; Basic, M.; Topuzovic, N.; Babic, C.; Medved, V.

    1989-01-01

    Cerebral blood flow was measured in relative terms with Tc99m-hexamethylpropyleneamineoxim (HMPAO) and single photon emission computed tomography (SPECT) in 28 female schizophrenic patients (20 acute and 8 chronic) classified according to DSM-III. Eleven normals served as controls. The acute patients were classified according to positive and negative symptoms. Patients with predominantly positive symptoms showed by and large normal and homogeneous cerebral isotope uptake. Those with negative symptoms, and the chronic patients, showed inhomogeneous tracer uptake with multiple regions of hypoperfusion in slices 4-6 cm above the orbitomeatal line. The findings support in principle the notion that schizophrenia with negative or chronic symptoms does not affect the whole brain homogeneously. Brain imaging with Tc99m-HMPAO and SPECT might be used to distinguish various types of schizophrenia. (author)

  20. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  1. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  2. Cerebral blood flow abnormalities induced by transient hypothyroidism after thyroidectomy. Analysis by Tc-99m-HMPAO and SPM96

    International Nuclear Information System (INIS)

    Nagamachi, Shigeki; Jinnouchi, Seishi; Nishii, Ryuichi; Ishida, Yasushi; Fujita, Seigo; Futami, Shigemi; Kodama, Takao; Tamura, Shozo; Kawai, Keiichi

    2004-01-01

    The current study is an investigation of alterations in regional cerebral blood flow (rCBF) distribution in patients with transient hypothyroidism after thyroidectomy. In addition, the effects of thyroxine treatment on rCBF changes were studied. Noninvasive rCBF measurements using 99m Tc-HMPAO SPECT were performed on 24 post-thyroidectomy patients who were in a hypothyroidic state. The measurements were conducted before 131 I therapy and after thyroid hormone (thyroxine) replacement. We used adjusted rCBF images (normalization of global CBF for each subject to 50 ml/100 g/min with proportional scaling) to compare these data with age-matched normal control groups (n=15) using statistical parametric mapping (SPM) 96. We also compared the absolute rCBF value of hypothyroidic patients with those of normal control groups. In addition, the association between rCBF alteration and the severity of depression was also analyzed. Finally, the effect of thyroid hormone replacement on rCBF was investigated individually using the Jack-knife test, in which patient data were compared with those from healthy volunteers. According to the result of this test, all cases were categorized into three subgroups, namely, improved, unchanged group and normal. To prove the reversibility of rCBF alteration after thyroid hormone replacement, a group comparison test between the normal controls and the improved group was done before and after thyroid hormone replacement. Similarly a group comparison test between the unchanged group and normal controls was also performed. In the hypothyroidic condition, there was a significant decrease in the posterior part of the bilateral parietal lobes and in part of the bilateral occipital lobes, including the cuneus. These decreased rCBF areas extended to the bilateral prefrontal cortices as deterioration became more profound. On individual analysis, 16 of 24 patients (66.7%) demonstrated rCBF reduction, while 8 patient did not show significant rCBF change

  3. Brain SPECT of chronic fatigue syndrome (CFS): SPM analysis of two age groups

    International Nuclear Information System (INIS)

    Barnden, L.; Casse, R.; Kwiatek, R.; Kitchener, M.; DelFante, P.; Burnet, R.; Behin-Ain, S.; Unger, S.

    2002-01-01

    Full text: Chronic fatigue syndrome (CFS) is a complex disorder characterised by profound fatigue and neuropsychiatric dysfunction. Previous studies with cerebral perfusion SPECT (rCBF) scans were performed with inhomogeneous patient populations and were not analysed with Statistical Parametric Mapping (SPM). We have used SPM to study subjects with moderate CFS based on the Fukuda criteria, who were not on medication and not depressed, compared to age matched control subjects. An apparent bimodal age distribution has been observed in CFS. Subjects were therefore divided into two age groups: 16-35 or under 35 (17 CFS, 11 control) and 36-61 or over 35 (15 CFS, 15 control). HMPAO brain SPECT was acquired on a 3-head camera. After lower window scatter subtraction, reconstruction with attenuation correction (mu=0.15/cm) and editing of facial activity, scans were spatially normalised (affine + 2x3x2 nonlinear) to SPM's anatomical space. SPM statistical analysis yielded the location, amplitude and corrected p-value of significant focal rCBF deficits. They were: for under 35, left lateral temporal lobe (13%, 0.004), the left insular region (15%, 0.006) and the right lentiform nucleus (15%, 0.01); and for over 35 the left lentiform nucleus (18%, 0.01). Counts at the most significant voxel in the under 35 age group permitted separation of the CFS and control groups with sensitivity 94% and specificity 100%. We are acquiring more controls to better define the age and sex dependence of rCBF in CFS. Analysis of associated clinical variables will be used to investigate the observed differences between the two age groups. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  4. Cerebral control of bladder storage in patients with detrusor overactivity: An activation study using SPECT with NEUROSTAT

    International Nuclear Information System (INIS)

    Yafu, Y.; Li, X.; Li, Y.

    2007-01-01

    Full text: The aim of this study was to identify the brain areas which control the bladder storage in the patients with detrusor overactivity (DO) and those without DO by 99mTc-hexamethylpropylene amine oxime (99mTc-HMPAO) SPECT with Neurological Statistical Image Analysis Software (NEUROSTAT). Methods: SPECT scans were performed on fifteen healthy volunteers (Group I) and twenty-five patients with some storage symptoms of lower urinary tract, among whom nineteen patients were with DO (Group II) and six patients were with normal detrusor function (Group III). All the subjects were male and right-handed. Each subject was scanned twice without movement in a supine position. 444MBq and 555MBq 99mTc- HMPAO were separately injected intravenously under the following two conditions: resting state with empty bladder and urine withholding state with full bladder. The final image during urine withholding was obtained by subtracting the first scan data from the second. NEUROSTAT was adopted to analyze the difference in rCBF between groups in resting state and to analyze the change in rCBF between urine withholding and resting states in each group. The results were displayed on Z-score images at a significance threshold of P < 0.05 with correction for multiple comparisons. Results: No region reached significant threshold in comparison of Group II and Group III in resting state, although Group II and III , as compared with Group I, showed decreases in tracer activity in superior temporal gyrus, medial frontal gyrus, inferior frontal gyrus, anterior cingulate and cingulate gyrus. There were significant increases in tracer activity in bilateral inferior frontal gyri and the right middle temporal gyrus in urine withholding state as compared with resting state in Group III. Among the regions, the right inferior frontal gyrus was distinctly prominent at both Z-score and the extent. In Group II, the regions that were activated significantly in Group III did not reach significant

  5. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual {sup 201} Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of the coronary reserves; Deteccion de viabilidad miocardica mediante tomografia por emision de foton unico (SPECT perfusorio) dual {sup 201} Talio (Reposo de 15 minutos, 24 horas tardio y 24 horas reinyeccion) y gated-SPECT {sup 99m} Tc-SESTAMIBI en esfuerzo o estimulo de reserva coronaria

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza V, R

    2004-07-01

    The objective of this work was to determine if the images of SPECT {sup 201} TI in rest of 15 minutes, 24 late hours and Gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of {sup 201}TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT {sup 201} TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of {sup 201}TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT {sup 99m}Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  6. Therapeutic monitoring of intracerebral perfusion disturbances secondary to subarachnoid haemorrhage (SAH) by means of Tc-99m-HMPAO SPECT

    International Nuclear Information System (INIS)

    Locher, J.T.; Bruehlmeier, M.; Landolt, H.

    2002-01-01

    Aim: Aneurysmal SAH is a devastating illness as two-thirds of the patients are disabled or die. Modern concepts of treatment include the prevention of the most serious complications after a surgical intervention (clipping, coiling) such as re-bleeding, vasospasms and stroke. The follow-up of cerebral perfusion could provide an objective basis for treatment. Material and Methods: In order to control the recently developed ''3H-therapy'' (hypertension-hypervolemia-hemodilution) we use the diagnostic possibilities of trans-cranial Doppler sonography (TCD), Tc-99m-HMPAO SPET (with semiquantitative parametric display) and angiography. Our algorithm includes a daily TCD, and, as a routine, the perfusion SPET on postoperative days 2/3, 8/10 and/or in case of a worsening of TCD results or neurological state. Results: In 20 consecutive cases 51 perfusion SPETs have been performed. Although, in general, a moderate 3H-therapy will be implemented postoperatively even without vasospasms or clinical signs the corrections of dosage highly depends on the TCD and SPET results. Vasospasms were the common reason for increased flow velocities measured by TCD and a (graduate) hypoperfusion on SPET (15 cases), but in three cases SPET showed a local or contra-lateral luxury perfusion indicative for stroke and, therefore, implicating a reduction/termination of the 3H-therapy. Conclusion: Our experiences with the new concept demonstrate not only a diagnostic performance of the used techniques but also an improved effectiveness of cost and benefit

  7. Occipital lobe and posterior cingulate perfusion in the prediction of dementia with Lewy body pathology in a clinical sample.

    Science.gov (United States)

    Prosser, Angus M J; Tossici-Bolt, Livia; Kipps, Christopher M

    2017-12-01

    The aim of this study was to investigate the diagnostic value of occipital lobe and posterior cingulate perfusion in predicting dopamine transporter imaging outcome using a quantitative measure of analysis. In total, 99 patients with cognitive complaints who had undergone both technetium-99m-hexamethylpropyleneamine oxime single-photon emission computed tomography (Tc-HMPAO SPECT) and I ioflupane (I-FP-CIT also called DaTSCAN) imaging in a dementia diagnostic center were analyzed. Measures of perfusion were calculated from HMPAO SPECT images for the medial and lateral occipital lobe, the posterior cingulate cortex, precuneus and cuneus regions of interest using statistical parametric mapping 8. DaTSCAN images were quantified and specific binding ratios were calculated independent from HMPAO SPECT results. Statistical parametric mapping and tests of associations between perfusion and I-FP-CIT imaging were completed. Regions of interest on HMPAO yielded poor predictive values when used independently to predict I-FP-CIT status; however, the combination of normal posterior cingulate perfusion with medial and lateral occipital hypoperfusion was associated significantly with I-FP-CIT status, χ (1, N=99)=9.72, P=0.002. This combination also yielded a high positive likelihood ratio and specificity (11.1, 98%). Sensitivity was, however, low (22%). No significant perfusion differences were found when abnormal and normal I-FP-CIT groups were compared directly using voxel-based morphometry (Poccipital hypoperfusion with preserved posterior cingulate gyrus perfusion is highly specific for individuals with a positive I-FP-CIT scan in a clinical sample where diagnostic doubt exists. This regional combination, however, lacks sensitivity; therefore, absence of the sign cannot be used to rule out dementia with Lewy bodies. A positive finding provides strong evidence to rule in dementia with Lewy bodies.

  8. Regional cerebral blood flow in neuropediatrics; Regionalny przeplyw mozgowy krwi w chorobach neuropediatrycznych

    Energy Technology Data Exchange (ETDEWEB)

    Junik, R [Katedra i Klinika Endokrynologii i Diabetologii, Akademia Medyczna, Bydgoszcz (Poland); Katedra i Klinika Endokrynologii i Przemiany Materii, Akademia Medyczna, Poznan (Poland)

    2001-07-01

    Single photon emission computed tomography can effectively and non-invasively measure regional blood flow. Mostly used 99mTc-HMPAO is a safe brain imaging agent for pediatric applications. The radiation dose is acceptable. Knowledge of the normal rCBF pattern, including normal asymmetries and variations due to age, is necessary prerequisite for the evaluation and reporting of the results of 99mTc-HMPAO brain SPECT studies in clinical practice. The interpretation of he rCBF study in a child requires knowledge of normal brain maturation. The aim of the present review is to focus on the contribution to clinical developmental neurology of SPECT The clinical use of SPECT in developmental neurology are epilepsy, brain death, acute neurological loss including stroke, language disorders, cerebral palsy, high-risk neonates, hypertension due to renovascular disease, traumatic brain injury, migraine, anorexia nervosa, autism, Gilles de la Tourette syndrome, attention deficit disorder-hyperactivity, and monitoring therapy. Sedation is not routinely used, rather each child is evaluated. However, drug sedation is mandatory in some uncooperative children. (author)

  9. Regional cerebral blood flow in neuropediatrics

    International Nuclear Information System (INIS)

    Junik, R.

    2001-01-01

    Single photon emission computed tomography can effectively and non-invasively measure regional blood flow. Mostly used 99mTc-HMPAO is a safe brain imaging agent for pediatric applications. The radiation dose is acceptable. Knowledge of the normal rCBF pattern, including normal asymmetries and variations due to age, is necessary prerequisite for the evaluation and reporting of the results of 99mTc-HMPAO brain SPECT studies in clinical practice. The interpretation of he rCBF study in a child requires knowledge of normal brain maturation. The aim of the present review is to focus on the contribution to clinical developmental neurology of SPECT The clinical use of SPECT in developmental neurology are epilepsy, brain death, acute neurological loss including stroke, language disorders, cerebral palsy, high-risk neonates, hypertension due to renovascular disease, traumatic brain injury, migraine, anorexia nervosa, autism, Gilles de la Tourette syndrome, attention deficit disorder-hyperactivity, and monitoring therapy. Sedation is not routinely used, rather each child is evaluated. However, drug sedation is mandatory in some uncooperative children. (author)

  10. Brain SPECT study of detrusor overactivity and healthy men in urine withholding

    International Nuclear Information System (INIS)

    Yin Yafu; Li Xuena; Li Yaming; Noriyuki Shuke; Atsutaka Okizaki; Junichi Sato; Tamio Aburano

    2009-01-01

    The aim of the study is to identify the brain areas, which control the bladder storage by 99 Tc m -HMPAO SPECT with Neurological Statistical Image Analysis Software (NEUROSTAT). SPECT were performed on twenty-five patients with some storage symptoms of lower urinary tract, among which nineteen patients were with detrusor overactivity (DO) (Group II) and six patients were with normal detrusor function (Group III), and fifteen healthy volunteers (Group I). All the subjects were male and right-handed, and were scanned twice under two conditions: resting state and urine withholding state. NEUROSTAT was adopted to analyze the difference in rCBF between groups and states. The results were displayed on Z-score images at a significance threshold of P<0.05 with correction for multiple comparisons. No region reached significant threshold in comparison of Group II and III in resting state. There were significant increases in tracer activity in bilateral inferior frontal gyri and the right middle temporal gyrus in urine withholding state as compared with resting state in Group I and III (P<0.05 with correction for multiple comparisons, the corresponding Z value was more than 4.476 for Group I, more than 4.414 for Group III). Among the regions,the right inferior frontal gyrus was distinctly prominent at both Z-score and the extent. In Group II, only the left middle temporal gyrus and middle frontal gyrus were activated significantly in urine withholding state as compared with resting (P<0.05 with correction for multiple comparisons, the corresponding Z value was more than 4.35). The results indicated that bilateral inferior frontal gyri and the right middle temporal gyrus associated with the control of bladder storage.Especially, the right inferior frontal gyrus played a more important role in cerebral control of bladder storage, inhibiting the contraction of detrusor in urine storage. (authors)

  11. Identification of inflammatory processes in temporomandibular joint (TMJ) by {sup 99m}Tc-HMPAO in animal model; Identificacao de processos inflamatorios na articulacao temporomandibular por {sup 99m}Tc-HMPAO em modelo animal

    Energy Technology Data Exchange (ETDEWEB)

    Brasileiro, Claudia Borges; Cardoso, Valbert Nascimento; Lima, Carla Flavia de; Campos, Tarcisio Passos Ribeiro de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares]. E-mail: campos@nuclear.ufmg.br

    2005-07-01

    Temporomandibular joint (TMJ) is a synovial joint that represents the junction of mandible with skull. TMJ and mastication muscles are affected by temporomandibular disorders (TMDs). During the last two decades the advances in imaging diagnostic of TMJ have greatly contributed to the assessment of the TMJ disorders. Labelled leukocytes with technetium- 99m hexamethyl propylene amine oxime ({sup 99m}Tc-HMPAO) represent an efficient method that generates images based in physiological and/or biochemical changes related to inflammation. The aim of this study was to investigate the potential usefulness of technetium-99m labelled leukocytes scintigraphy in the diagnosis of TMJ inflammatory process applying a rabbit TMJ arthritis model. Arthritis was induced unilaterally with an intra-articular injection of ovalbumin in left ATM. On the contra-lateral side, the same dose of saline was injected. After five days, leukocytes were labeled with HMPAO and {sup 99m}Tc-HMPAO TMJ scintigraphic images were made. After twelve days a computed tomography was realized. Scintigraphic images obtained five days after induction of TMJ inflammation showed the localization of inflammatory process. The results were expressed as cpm of activity found in left ATM and contra-lateral side. Significant differences of activity were found between inflamed articulation and contra-lateral side (P = 0,0073). In conclusion, the method of leukocytes labeled with {sup 99m}Tc showed to be sensitive in detection of inflammatory disorders of TMJ and can be of great value in early diagnostic of these disorders. (author)

  12. Regional differences between {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi [Department of Nuclear Medicine and Radiology, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryomachi Aoba-ku, 980-8575, Sendai (Japan)

    2003-11-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8{+-}6.6 years) were assigned to {sup 99m}Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6{+-}6.7 years) to {sup 99m}Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  13. Non-invasive brain stimulation enhances the effects of Melodic Intonation Therapy

    Directory of Open Access Journals (Sweden)

    Bradley W. Vines

    2011-09-01

    Full Text Available Research has suggested that a fronto-temporal network in the right hemisphere may be responsible for mediating Melodic Intonation Therapy’s positive effects on speech recovery. We investigated the potential for a non-invasive brain stimulation technique, transcranial direct current stimulation (tDCS, to augment the benefits of MIT in patients with non-fluent aphasia by modulating neural activity in the brain during treatment with MIT. The polarity of the current applied to the scalp determines the effects of tDCS on the underlying tissue: anodal tDCS increases excitability, whereas cathodal tDCS decreases excitability. We applied anodal tDCS to the posterior inferior frontal gyrus (IFG of the right hemisphere, an area that has been shown to both contribute to singing through the mapping of sounds to ariculatory actions and serve as a key region in the process of recovery from aphasia, particularly in patients with large left hemispheric lesions. The stimulation was applied while patients were treated with MIT by a trained therapist. Six patients with moderate to severe non-fluent aphasia underwent three consecutive days of anodal-tDCS+MIT, and an equivalent series of sham-tDCS+MIT. The two treatment series were separated by one week, and the order in which the treatments were administered was randomized. Compared to the effects of sham-tDCS+MIT, anodal-tDCS+MIT led to significant improvements in fluency of speech. These results support the hypothesis that, as the brain seeks to reorganize and compensate for damage to left-hemisphere language centers, combining anodal-tDCS with MIT may further recovery from post-stroke aphasia by enhancing activity in a right-hemisphere sensorimotor network for articulation.

  14. Study of cellular retention of HMPAO and ECD in a model simulating the blood-brain barrier; Etude de la retention cellulaire de l`HMPAO et de l`ECD dans un modele simulant la barriere hematoencephalique

    Energy Technology Data Exchange (ETDEWEB)

    Ponce, C.; Pittet, N.; Slosman, D.O. [HUG, 1211 Geneve 14, (Switzerland)

    1997-12-31

    The HMPAO and ECD are two technetium-labelled lipophilic agents clinically used in the imagery of cerebral perfusion. These molecules cross the membranes and are retained inside the cell after being converted to a hydrophilic form. The aim of this study is to establish the distribution of this retention at the level of blood-brain barrier (BBB) and nerve cells. The incorporation of HMPAO or ECD was studied on a model of co-culture simulating the BBB by means of a T84 single-cell layer of tight junction separated from another layer of U373 astrocyte cells. The cell quality and tight junction permeability were evaluated by the cellular retention of 111-indium chloride and by para-cellular diffusion of {sup 14}C mannitol,d-1. The values reported below were obtained at 180 minutes when the radiotracers were added near the `T84 layer`. The cell quality is validated by the low cellular retention of the indium chloride(2.3{+-}0.3 {mu}g{sup -1} for the T84 cells and 8.2{+-}5.8 {mu}g{sup -1} for the U373 cells). The activity of {sup 14}C mannitol,d-1 diminishes by 23 {+-} 5 % in the added compartment. The retention of ECD by the U373 cells is significantly higher (20.7 {+-}4.5 g{sup -1}) than that of T84 cells (2.9 {+-} 0.2 {mu}g{sup -1}). For HMPAO a non-significant tendency could be observed (49 {+-} 34 {mu}g{sup -1} for the U373 cells and 38 {+-} 25 {mu}g{sup -1} for the T84 cells)> The results of cellular retention of indium by HMPAO or ECD when added near `U373 layer` are not significantly different.In conclusion, independently of the side exposed to the radiotracers, one observes an enhanced incorporation of the U373 cells. The ensemble of these results represent additional arguments in favour of a specific cellular incorporation of the radiotracers, independent of the BBB permittivity

  15. Kommunikation mit Mitarbeitern

    Science.gov (United States)

    Spychala, Anne; Fleischmann, Jürgen

    Kommunikation ist der Austausch von Nachrichten und Informationen zwischen Mitarbeitern eines Unternehmens (O'Hair et al. 1997). Dieser Austausch kann persönlich, aber z.B. auch per Telefon, E-Mail oder durch Computersysteme erfolgen. In diesem Kapitel betrachten wir die persönliche Kommunikation zwischen Vorgesetzten und Mitarbeitern. Zur persönlichen Kommunikation mit Mitarbeitern zählen sowohl formelle Gespräche mit Mitarbeitern als auch eher informelle Gespräche zwischen Tür und Angel. Die Gespräche können dabei mit einzelnen Mitarbeitern (z.B. jährliches Mitarbeitergespräch) oder mit Gruppen von Mitarbeitern (z.B. regelmäßige Projekt- oder Teambesprechungen) stattfinden.

  16. Behandlung von Herzrhythmusstörungen mit Magnesium bei Patienten mit Herzinsuffizienz

    Directory of Open Access Journals (Sweden)

    Wink K

    2002-01-01

    Full Text Available Die medikamentöse Behandlung von Herzrhythmusstörungen ist unbefriedigend, da bei guter Wirksamkeit durch die Proarrhythmie eine Verbesserung der Prognose gefährdet und nicht gesichert ist. Man kann davon ausgehen, daß Magnesiumsalze keine arrhythmogene Effekte aufweisen. Bei Patienten mit einer Herzinsuffizienz besteht häufig ein Mg-Mangel, der durch gastrointestinale Störungen, neurohormonale Regulationen, aber auch durch die Therapie (Diuretika,Digitalisbedingt ist. An Patienten mit einer Herzinsuffizienz müßte sich demnach zeigen lassen, ob die Mg-Substitution einen antiarrhythmischen Effekt aufweist. In fünf placebokontrollierten Studien konnte gezeigt werden, daß sich teil weise signifikant und mit ausreichen der Aussagekraft (PowerArrhythmien bei Patienten mit Herzinsuffizienz durch orale und parenterale Gabe von Mg-Salzen reduzieren lassen. Trotz Einschränkungen wie z.B. inadäquates Design, fehlende Vermeidung von Bias, ungenügende Vergleichbarkeit der Behandlungsgruppen, inadäquate Auswertung und ungenügende Berücksichtigung der Spontanvariation läßt sich aufgrund der Ergebnisse der Studien die Hypothese aufstellen, daß Magnesiumsalze bei Patienten mit Herzinsuffizienz Herzrhythmusstörungen günstig beeinflussen können. Prospektive, randomisierte,verblindete und kontrollierte konfirmatorische Studien mit ausreichenden Fallzahlen sind jedoch notwendig, um diese Hypothese zu bestätigen.

  17. Delayed decrease in hemispheric cerebral blood flow during Wada test demonstrated by 99mTc-HMPAO single photon emission computer tomography

    International Nuclear Information System (INIS)

    Ryding, E.; Sjoeholm, H.; Skeidsvoll, H.; Elmqvist, D.

    1989-01-01

    We describe how brain regions with a flow (and metabolism) decrease can be visualized after an injection of short-acting barbiturate in one of the internal carotid arteries during a Wada test. An intravenous administration of 99mTc-HMPAO was used to mark the relative flow distribution. The 99mTc-HMPAO distribution in the brain was recorded three-dimensionally about 1 h later, by means of a single photon emission computer tomograph. We show that the timing of the intravenous 99mTc-HMPAO administration during the Wada test is important for the visualization of the low-flow regions. The administration of the tracer substance should be delayed at least 30 s after the first signs of the barbiturate effect. The rCBF decrease in the barbiturate-injected cerebral hemisphere was associated with a simultaneous decrease in the contralateral, pharmacologically not directly affected, cerebellar hemisphere (crossed cerebellar diaschisis). (author)

  18. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  19. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  20. Marketing mit Youtube

    OpenAIRE

    Nufer, Gerd; Kaps, Anne

    2017-01-01

    Die Video-Plattform Youtube ist eine der meistbesuchten Webseiten weltweit. Youtube-Stars erreichen mit ihren Videos große Zuschauergruppen und können als Multiplikatoren für Werbebotschaften dienen. Sie sind oftmals Meinungsführer, denen hohes Vertrauen entgegengebracht wird, weshalb sie sich sehr gut für Influencer-Marketing eignen. Marketing mit Youtube ermöglicht eine offene, mehrwegige, schnelle und kostengünstige Kommunikation mit Kunden, insbesondere jüngeren. Unternehmen können sich d...

  1. Study of cellular retention of HMPAO and ECD in a model simulating the blood-brain barrier

    International Nuclear Information System (INIS)

    Ponce, C.; Pittet, N.; Slosman, D.O.

    1997-01-01

    The HMPAO and ECD are two technetium-labelled lipophilic agents clinically used in the imagery of cerebral perfusion. These molecules cross the membranes and are retained inside the cell after being converted to a hydrophilic form. The aim of this study is to establish the distribution of this retention at the level of blood-brain barrier (BBB) and nerve cells. The incorporation of HMPAO or ECD was studied on a model of co-culture simulating the BBB by means of a T84 single-cell layer of tight junction separated from another layer of U373 astrocyte cells. The cell quality and tight junction permeability were evaluated by the cellular retention of 111-indium chloride and by para-cellular diffusion of 14 C mannitol,d-1. The values reported below were obtained at 180 minutes when the radiotracers were added near the 'T84 layer'. The cell quality is validated by the low cellular retention of the indium chloride(2.3±0.3 μg -1 for the T84 cells and 8.2±5.8 μg -1 for the U373 cells). The activity of 14 C mannitol,d-1 diminishes by 23 ± 5 % in the added compartment. The retention of ECD by the U373 cells is significantly higher (20.7 ±4.5 g -1 ) than that of T84 cells (2.9 ± 0.2 μg -1 ). For HMPAO a non-significant tendency could be observed (49 ± 34 μg -1 for the U373 cells and 38 ± 25 μg -1 for the T84 cells)> The results of cellular retention of indium by HMPAO or ECD when added near 'U373 layer' are not significantly different.In conclusion, independently of the side exposed to the radiotracers, one observes an enhanced incorporation of the U373 cells. The ensemble of these results represent additional arguments in favour of a specific cellular incorporation of the radiotracers, independent of the BBB permittivity

  2. {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD perform differently in typically hypoperfused areas in Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Koulibaly, Pierre Malick [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Laboratoire de Biophysique, Universite de Nice-Sophia Antipolis, UFR de Medecine, 28 Avenue de Valombrose, 06107, Nice Cedex 2 (France); Nobili, Flavio; Vitali, Paolo; Girtler, Nicola; Rodriguez, Guido [Clinical Neurophysiology, Department of Internal Medicine, University of Genoa (Italy); Migneco, Octave; Darcourt, Jacques [Nuclear Medicine Department, Centre Antoine Lacassagne, University of Nice-Sophia Antipolis (France); Robert, Philippe H. [Memory Center, Federation of Clinical Neuroscience, Centre Hospitalier Universitaire, University of Nice-Sophia Antipolis (France)

    2003-07-01

    Technetium-99m hexamethylpropylene amine oxime (HMPAO) and {sup 99m}Tc-N,N''-1,2-ethylene diylbis-l-cysteine diethyl ester dihydrochloride (ECD) yield significantly different images of cerebral perfusion owing to their particular pharmacokinetics. The aim of this study was to assess the topography, extension and statistical significance of these differences in Alzheimer's disease (AD). Sixty-four patients with mild to moderate AD were retrospectively selected by two European centres. Two series of patients, including 32 studied with {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and 32 studied with {sup 99m}Tc-ECD SPET, were matched for sex, age ({+-}3 years) and severity of cognitive impairment as assessed by the Mini-Mental State Examination (MMSE) ({+-}2 points), following a case-control procedure. SPET data were processed using SPM99 software (uncorrected height threshold: P=0.001). {sup 99m}Tc-ECD SPET gave significantly higher uptake ratio values than {sup 99m}Tc-HMPAO SPET in several symmetrical clusters, including the right and left occipital cuneus, the left occipital and parietal precuneus, and the left superior and middle temporal gyri. {sup 99m}Tc-HMPAO SPET gave significantly higher uptake ratio values than ECD in two smaller clusters, including the hippocampus in both hemispheres. In AD, relative brain uptake of {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is different in several brain regions, some of which are typically involved in AD, such as the precuneus and the hippocampus. These differences confirm the need for specific normal databases, but their impact on routine SPET reports in AD is not known and deserves an ad hoc investigation. (orig.)

  3. Quantitative assessment of blood flow reserve using {sup 99m}Tc-HMPAO in carotid stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Garai, I.; Varga, J.; Galuska, L. [Department of Nuclear Medicine, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Szomjak, E. [3. Department of Internal Medicine, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Toth, C.; Olvaszto, S. [1. Department of Surgery, University of Debrecen Medical and Health Centre, Debrecen (Hungary); Bank, J. [Department of Neurology, Kenezy Hospital (Hungary); Ficzere, A. [Department of Neurology, University of Debrecen Medical and Health Centre, Debrecen (Hungary)

    2002-02-01

    Dynamic imaging of the inflow of technetium-99m hexamethylpropylene amine oxime (HMPAO) to the brain has been proved to allow estimation of the hemispherical cerebral blood flow (CBF) using the Patlak plot. In this study, we compared the hemispherical CBF (in ml/min/100 g) of different patient groups. A total of 25 patients (comprising 13 with migraine and 12 scheduled for endarterectomy owing to angiographically confirmed severe stenosis of the internal carotid artery on at least one side) underwent baseline and acetazolamide {sup 99m}Tc-HMPAO brain perfusion studies. In addition, acetazolamide {sup 99m}Tc-HMPAO studies were performed in 12 healthy subjects (no baseline study was performed for ethical reasons.) Dynamic studies were acquired by means of a dual-detector gamma camera with a large field of view (HELIX, Elscint). Special difference images were created to make definition of the aortic arch and hemispherical brain regions easier and more reproducible. A semi-automatic method was developed to determine the transit time from the aorta to the brain, making the generation of the Patlak plot even more robust. The baseline CBF values did not significantly depend on the disease (P>0.1), whereas the CBF values obtained after acetazolamide provocation did do so (ANOVA, P<0.001). Patients suffering from migraine showed a significant increase in global CBF values after acetazolamide provocation (paired t test, P<0.05), but we could not find any effect of the provocation in patients awaiting carotid endarterectomy, indicating a lack of cerebrovascular reserve capacity. Comparison of the results of the acetazolamide study in patients and the control group revealed the CBF values to be significantly lower in patients with carotid stenosis (two-sample t-test, P<0.001), but not in those with migraine (P>0.1). In summary, using quantitative analysis of {sup 99m}Tc-HMPAO brain studies we could objectively compare the CBF of patients suffering from different diseases

  4. Comparison of simultaneous 99mTc-HMPAO and 111In oxine labelled white cell scans in the assessment of inflammatory bowel disease

    International Nuclear Information System (INIS)

    Allan, R.A.; Bassingham, S.; Lazarus, C.; Clarke, S.E.M.; Fogelman, I.; Sladen, G.E.

    1993-01-01

    Forty-seven patients, 29 with chronic inflammatory bowel disease (IBD) and 18 with presumed irritable bowel syndrome, including one with uncomplicated diverticular disease, were studied with simultaneous technetium-99m hexamethylpropylene amine oxime and indium-III oxine labelled leucocyte scans performed at 1, 3 and 24 h. Twenty-seven patients with IBD had active disease as judged by clinical and laboratory criteria and all of these had positive scans with both agents. No false positive studies were obtained. The 1-h 99m Tc-HMPAO WBC scans showed the same distribution to disease as the 3-h 111 -In WBC scans, with no difference in intensity (P 111 -In scans. The 3-h 99m Tc-HMPAO WBC scans showed more extensive disease (P 111 In WBC scans. Physiological bowel activity on 3-h 99m Tc-HMPAO WBC scans was present in 12 patients but was faint and did not interfere with assessment of disease extent and activity. It is concluded that in terms of isotope availability, radiation dosimetry and image quality, 99m Tc-HMPAO is the agent of choice in detecting active IBD, with localization of disease possible at 1-h after re-injection and optimal resolution and definition of disease extent at 3 h. A negative scan reliably excludes active disease. (orig.)

  5. Dementia and functional cerebral imaging a reevaluation

    International Nuclear Information System (INIS)

    Steinling, M.; Lecouffe, P.; Pham, T.; Charpentier, P.; Delebvre, L.; Lavenu, I.; Pasquier, F.; Charpentier, P.; Duhamel, A.

    2000-01-01

    New concepts which concerned especially the nosologic classification of dementia as for example Dementia with Lewy Bodies (DLB) incite to revalue the main characteristics of the regional cerebral blood flow measurements studied by SPECT in several forms of dementia. SPECT analysis with 99m-Technetium HMPAO (555 MBq) was performed to 20 patients with probable DLB, 20 patients with probable Alzheimer's disease (AD) and 20 patients with Fronto-Temporal dementia (FTD). Ten pairs of regions of interest were analysed. Tracer uptake was expressed as a cortico-cerebellar activity ratio. Statistical analysis of index of fixation was performed using an univariate analysis of variance, and a selection of significative ROIs was performed using two cut-off values (80 and 82.5 %). In the FTD group, a decrease of HMPAO uptake in frontal cortical regions of interest (internal, lateral and posterior) was observed. In the DLB group the decrease of HMPAO uptake was widespread and concerned all the cortical regions of interest except the posterior frontal and occipital regions. Finally in the AD group there was a limited temporal and parietal hypoperfusion more marked on the left side without frontal hypoperfusion. This last result was obtained whatever the cognitive impairment. Consequently it seems that the frontal hypoperfusion previously reported in AD groups was induced by the fact that patients with DLB were also included because the diagnosis was not established. In conclusion we estimate that SPECT studies could be used more often in clinical research especially for a classification approach of dementia. (authors)

  6. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  7. Identification of inflammatory processes in temporomandibular joint (TMJ) by 99mTc-HMPAO in animal model

    International Nuclear Information System (INIS)

    Brasileiro, Claudia Borges; Cardoso, Valbert Nascimento; Lima, Carla Flavia de; Campos, Tarcisio Passos Ribeiro de

    2005-01-01

    Temporomandibular joint (TMJ) is a synovial joint that represents the junction of mandible with skull. TMJ and mastication muscles are affected by temporomandibular disorders (TMDs). During the last two decades the advances in imaging diagnostic of TMJ have greatly contributed to the assessment of the TMJ disorders. Labelled leukocytes with technetium- 99m hexamethyl propylene amine oxime ( 99m Tc-HMPAO) represent an efficient method that generates images based in physiological and/or biochemical changes related to inflammation. The aim of this study was to investigate the potential usefulness of technetium-99m labelled leukocytes scintigraphy in the diagnosis of TMJ inflammatory process applying a rabbit TMJ arthritis model. Arthritis was induced unilaterally with an intra-articular injection of ovalbumin in left ATM. On the contra-lateral side, the same dose of saline was injected. After five days, leukocytes were labeled with HMPAO and 99m Tc-HMPAO TMJ scintigraphic images were made. After twelve days a computed tomography was realized. Scintigraphic images obtained five days after induction of TMJ inflammation showed the localization of inflammatory process. The results were expressed as cpm of activity found in left ATM and contra-lateral side. Significant differences of activity were found between inflamed articulation and contra-lateral side (P = 0,0073). In conclusion, the method of leukocytes labeled with 99m Tc showed to be sensitive in detection of inflammatory disorders of TMJ and can be of great value in early diagnostic of these disorders. (author)

  8. The role of FDG-PET, HMPAO-SPET and MRI in the detection of brain involvement in patients with systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Kao Chiahung [Department of Nuclear Medicine, Taichung Veterans General Hospital, Taichung (Taiwan, Province of China); Lan Jungliang [Division of Rheumatology, Taichung Veterans General Hospital, Taichung (Taiwan, Province of China); ChangLai Shengping [Department of Nuclear Medicine, Chung-Shan Medical and Dental College, Taichung (Taiwan, Province of China); Liao Kokaung [Electron Microscopic Laboratory, Chung-Shan Medical and Dental College, Taichung (Taiwan, Province of China); Yen Rouhfang; Chieng Poonung [Department of Nuclear Medicine, National Taiwan University Hospital, Taipei (Taiwan, Province of China)

    1999-02-01

    Involvement of the brain is one of the most important complications of systemic lupus erythematosus (SLE); however, its diagnosis is difficult due to the lack of effective imaging methods. We combined three brain imaging modalities - positron emission tomography with fluorine-18 2-fluoro-2-deoxy-d-glucose (FDG-PET), single-photon emission computed tomography with technetium-99m hexamethylpropylene amine oxime (HMPAO-SPET) and magnetic resonance imaging (MRI) - in order to detect brain involvement in SLE. Thirty-seven SLE patients, aged 22-45 years, were divided into three groups. Group 1 (G1) consisted of ten patients with major neuropsychiatric manifestations; group 2 (G2) consisted of 15 patients with minor manifestations; and group 3 (G3) consisted of 12 patients without manifestations. FDG-PET findings were abnormal in 51% of patients: 90% of G1, 67% of G2 and 0% of G3 patients respectively. HMPAO-SPET findings were abnormal in 62% of patients: 100% of G1, 73% of G2 and 17% of G3 patients respectively. MRI findings were abnormal in 35% of patients: 70% of G1, 40% of G2 and 0% of G3 patients respectively. Grey matter was more commonly involved than white matter; 62% of patients presented with lesions in the cerebral cortex, 27% with lesions in the basal ganglion, 5% with lesions in the cerebellum, and 19% with lesions in white matter. No white matter lesions were found on FDG-PET or HMPAO-SPET. However, in 19% of patients, MRI demonstrated abnormally high signal lesions in white matter. Forty-three percent of cases had positive serum anticardiolipin antibodies (ACA). However, ACA was not related to FDG-PET, HMPAO-SPET or MRI findings. It may be concluding that HMPAO-SPET is a more sensitive tool for detecting brain involvement in SLE patients when compared with FDG-PET or MRI. However, MRI is necessary for detecting lesions in white matter. (orig.) With 3 figs., 2 tabs., 46 refs.

  9. 99mTc-HMPAO SPECT in dementia of the Alzheimer type. Hypoperfusion in the medial temporal region

    International Nuclear Information System (INIS)

    Nakamura, Yu; Kawakatsu, Shinobu; Shinohara, Masao; Nadaoka, Toshihide; Totsuka, Shiro; Komatani, Akio

    1995-01-01

    This study examined regional cerebral blood flow (rCBF) by single photon emission computed tomography (SPECT) using technetium 99m-hexamethyl-propyleneamineoxime and correlated the results with neuropsychological findings in 30 patients with dementia of the Alzheimer type (AT dementia). Ten healthy persons served as controls. The group of mild AT dementia exhibited a significant decrease in rCBF in the lower part of the right lateral frontal lobe and in the right parietal lobe. In the group of moderate AT dementia, the significant decrease in rCBF was noted in the lower part of the bilateral frontal lobes, the parietal part of the temporal lobe, the parietal lobe, and the medial temporal lobe. Factor analysis for neuropsychological test revealed three factors involved in rCBF. There was a significantly positive correlation between the factor responsible for memory and recall and rCBF in the left frontal lobe, the anterior part of the lateral temporal lobe, and the medial temporal lobe. These findings suggested that disturbance of the memory circuit may exist in the medial temporal lobe and others as pathophysiology of AT dementia. (N.K.)

  10. Serial SPECT in children with partial epilepsy

    International Nuclear Information System (INIS)

    Hosoya, Machiko; Ushiku, Hideo

    1995-01-01

    We performed serial single-photon emission CT (SPECT) with N-isopropyl-p-( 123 I)-Iodoamphetamine to measure the regional cerebral blood flow (rCBF) in 15 children with partial epilepsy. SPECT showed focal changes in 14 cases. Ten cases had abnormalities in the initial SPECT and another four cases in the second test. The cases with normal rCBF in initial SPECT had been tested in an early phase after the onset, and then decreased rCBF were observed in the second SPECT. The cases with both abnormal rCBF in the initial SPECT and improved rCBF in the second SPECT showed good prognosis in clinico-electrophysiological evolutions. In cases with abnormal changes of rCBF in the second SPECT, clinical prognosis was found to be not so good. These findings suggest that serial SPECT may be used to follow the course of epilepsy. (author)

  11. SPECT 123-I-[FP-CIT] diagnostic in the presynaptic parkinsonism

    International Nuclear Information System (INIS)

    Piperkova, E.; Georgiev, R.; Dimitrova, M.; Daskalov, M.; Orosova, M.; Milanova, M.; Danon, S.

    2005-01-01

    were normal. Results: Visually, the striatal radiopharmaceutical activity was found to be lower on the left striatum in 5 patients with tremor, rigidity or other movement disorders on the right extremities. In 2 patients with motor impairment on the left part of the body the [ 123 I] FP-CIT hypofixation was found on the right striatum and in one female the scintigraphic changes involved the striatum bilaterally. In all these patients the [ 123 I] FP-CIT uptake ratio was lower in the contralateral striatum of the clinical symptoms. In these patients good L - Dopa treatment effect was established in the clinical follow-up. In one female without DaTSCAN brain SPECT abnormality and 99mTc-HMPAO perfusion changes, essential tremor and arteriosclerotic pseodoparkinsonism was accepted. To achieve good quality of the images it is recommended that the filters should be individually selected for each case. We consider that Butterworth filter of 3 th -5 th order and normalised cutoff frequency of 0.25-0.45 and Low Pass Cosine filter with normalised cutoff frequency of 0.25 are most effective at the image processing step. Conclusion: 123 I - Ioflupane SPECT can be very useful for early diagnostics of patients with clinically uncertain Parkinsonism. It could contribute to initial diagnosis, differential diagnosis between presynaptic parkinsonian syndromes (Progressive Supranuclear Palsy and Multiple System Atrophy) and ET and better subsequent therapeutic management

  12. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  13. A preliminary study of neuroSPECT evaluation of patients with post-traumatic smell impairment

    International Nuclear Information System (INIS)

    Eftekhari, Mohammad; Assadi, Majid; Kazemi, Majid; Saghari, Mohsen; Esfahani, Armaghan Fard; Sichani, Babak Fallahi; Gholamrezanezhad, Ali; Beiki, Davood

    2005-01-01

    Most olfactory testings are subjective and since they depend upon the patients' response, they are prone to false positive results. The aim of this study was to use quantitative brain perfusion SPECT in order to detect possible areas of brain activation in response to odorant stimulation in patients with post-traumatic impaired smell in comparison to a group of normal subjects. Fourteen patients with post-traumatic impaired smell and ten healthy controls were entered in this prospective study. All subjects underwent brain SPECT after intravenous injection of 740-MBq 99m Tc-ECD and 48 hours later, the same procedure was repeated following olfactory stimulus (vanilla powder). In most of seven regions of interest (Orbital Frontal Cortex, Inferior Frontal Pole, Superior Frontal Pole, Posterior Superior Frontal Lobe, Parasagittal Area, Occipital Pole, and Cerebellar area) the post-stimulation quantitative values show increased cortical perfusion being more pronounced in normal volunteers than the anosmic patients (except cerebellar areas and the right occipital pole). Maximal activation was observed in orbitofrontal regions (right+ 25.45% and left +25.47%). Brain SPECT is a valuable imaging technique in the assessment of post-traumatic anosmia and could be competitive as an alternative to other imaging techniques, especially when functional MRI is unavailable or unsuitable. However, this procedure may benefit from complementary MRI or CT anatomical imaging

  14. Brain SPECT in children

    International Nuclear Information System (INIS)

    Guyot, M.; Baulieu, J.L.

    1996-01-01

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author)

  15. Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology

    Science.gov (United States)

    Erlandsson, Kjell; Kacperski, Krzysztof; van Gramberg, Dean; Hutton, Brian F.

    2009-05-01

    D-SPECT (Spectrum Dynamics, Israel) is a novel SPECT system for cardiac perfusion studies. Based on CZT detectors, region-centric scanning, high-sensitivity collimators and resolution recovery, it offers potential advantages over conventional systems. A series of measurements were made on a β-version D-SPECT system in order to evaluate its performance in terms of energy resolution, scatter fraction, sensitivity, count rate capability and resolution. Corresponding measurements were also done on a conventional SPECT system (CS) for comparison. The energy resolution of the D-SPECT system at 140 keV was 5.5% (CS: 9.25%), the scatter fraction 30% (CS: 34%), the planar sensitivity 398 s-1 MBq-1 per head (99mTc, 10 cm) (CS: 72 s-1 MBq-1), and the tomographic sensitivity in the heart region was in the range 647-1107 s-1 MBq-1 (CS: 141 s-1 MBq-1). The count rate increased linearly with increasing activity up to 1.44 M s-1. The intrinsic resolution was equal to the pixel size, 2.46 mm (CS: 3.8 mm). The average reconstructed resolution using the standard clinical filter was 12.5 mm (CS: 13.7 mm). The D-SPECT has superior sensitivity to that of a conventional system with similar spatial resolution. It also has excellent energy resolution and count rate characteristics, which should prove useful in dynamic and dual radionuclide studies.

  16. Brain SPECT in childhood

    International Nuclear Information System (INIS)

    Tranquart, F.; Saliba, E.; Prunier, C.; Baulieu, F.; Besnard, J.C.; Guilloteau, D.; Baulieu, J.L.

    2001-01-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  17. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  18. Brain SPECT perfusion in children and adolescents poly drug abusers

    International Nuclear Information System (INIS)

    Ramos, R.R.N.; Etchebehere, E.C.S.C.; Santos, A.O.; Lima, M.C.L.; Ramos, C.D.; Camargo, E.E.; Silva, C.A.M.; Serrat, S.M.

    2002-01-01

    Polydrug abuse in children and adolescents is a major social problem. Aim: The aim of this study was to evaluate brain perfusion in polydrug abuser adolescents with brain SPECT imaging (BSI) using 99m Tc-HMPAO. Materials and Methods: Sixteen male polydrug abuser patients (11 to 18 years) were submitted to BSI. Forty-eight normal individuals (26 males, 22 females; 18 to 31 years) were used as a control group. Images were performed after an intravenous injection of 99m Tc-HMPAO in a dark, quiet room. Images were acquired in a camera-computer system equipped with a fan beam collimator. The images were reconstructed in the transaxial, coronal and sagittal views and submitted to semi-quantitative analysis using the thalami as reference, by placing regions of interest (ROIs) in the cerebral and cerebellar cortices. Patients were also submitted to neuropsychology tests and neurologic examination. Results: Significant hypoperfusion was found in the inferior portion of the frontal lobes (left and right: p<0.0001), temporal lobes (left lateral: p=0.0392; right lateral: p=0.0044; left and right mesial: p<0.0005), right parietal lobe (p=0.025), visual cortex (p=0.0013), pons (p = 0.0002), cerebellar hemispheres (left: p=0.0216; right: p=0.0005) and vermis (p=0.0015). An inverse relationship was observed between the degree of perfusion and the duration of drug abuse in the inferior left frontal lobe (? = -0.55; p=0.0255), superior right frontal lobe (? = -0.51; p=0.043), lateral right temporal lobe (? = -0.58; p=0.0172), mesial left temporal lobe (? -0.52; p=0.0384), left parietal lobe (? = -0.51; p=0.0416), basal ganglia (left: ? = -0.70; p=0.0022; right: ? = -0.65; p=0.0056) and cingulate gyrus (? = -0.66; p=0.0054). A significant correlation was observed between the perfusion of the temporal lobes with the Bender-Koppits test (left and right lateral: p=0.0559). Significant correlation was also noted between the perfusion of the lateral left temporal lobe (p=0.0559), parietal

  19. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    International Nuclear Information System (INIS)

    Lee, D. S.; Lee, S. K.; Jeong, J. K.; Lee, M. C.; Ko, C. S.

    1997-01-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study

  20. Frequencies and implications of discordant findings of interictal SPECT and itcal SPECT in patients with intractable epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D S; Lee, S K; Jeong, J K; Lee, M C; Ko, C S [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    1997-07-01

    Interictal SPECT could be used at best as a reference image to ictal SPECT, and cause sometimes confusion if it had given unexplained discordant findings from ictal SPECT. We investigated implications of discordant findings which occurred in 26 among 268 which found their epileptogenic zones using ictal EEG and/or operative outcome. Sensitivity of interictal SPECT was only 36%. Among these 268, 69 patients had no structural lesions on MR, 14 of whom had decreased perfusion on interictal SPECT (8 trues and 6 falses (adjacent or contralateral)). Structural lesion were found in 199 on MR, 103 of whom had decreased perfusion (89 trues and 14 falses). Among 26 having discordant cases, 10 interictal SPECT were proved wrong after operation and/or invasive EEG and the other 16 were on speculation using PET and ictal EEG. Ictal hyperperfusion was observed in 14 patients in these interictal SPECT. Six ictal studies were found postictal accompanied by contralateral propagation or not. Two patients had dual pathology, and the remaining 2 unknown. Interictal SPECT was done on the 2nd day after ictal study(24), the 3rd day (18), the 4th day(16), the 5th day (23). Four among 24 interictal studies (17%) of the 2nd day and the other 4 among 57 of 3rd to 5th day revealed ictal hyperperfusion on interictal SPECT. Six interictal studies (2.7% among 221) acquired on the indifferent day showed also ictal hyperperfusion. We could suggest that the next day is not desirable for interictal SPECT after ictal study, as ictal hyperperfusion on interictal study confounded more than postictal findings of ictal SPECT in the discrete localization than reassuring ictal study.

  1. Predictive value of dorso-lateral prefrontal connectivity for rTMS response in treatment-resistant depression: A brain perfusion SPECT study.

    Science.gov (United States)

    Richieri, Raphaëlle; Verger, Antoine; Boyer, Laurent; Boucekine, Mohamed; David, Anthony; Lançon, Christophe; Cermolacce, Michel; Guedj, Eric

    2018-05-18

    Previous clinical trials have suggested that repetitive transcranial magnetic stimulation (rTMS) has a significant antidepressant effect in patients with treatment resistant depression (TRD). However, results remain heterogeneous with many patients without effective response. The aim of this SPECT study was to determine before treatment the predictive value of the connectivity of the stimulated area on further rTMS response in patients with TRD. Fifty-eight TRD patients performed a brain perfusion SPECT before high frequency rTMS of the left dorsolateral prefrontal cortex (DLPFC). A voxel based-analysis was achieved to compare connectivity of the left DLPFC in responders and non-responders using inter-regional correlations (p left DLPFC and the right cerebellum in comparison to non-responders, independently of age, gender, severity of depression, and severity of treatment resistance. The area under the curve for the combination of these two SPECT clusters to predict rTMS response was 0.756 (p left DLPFC predicts rTMS response before treatment. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  2. Is there a role for Tc-99m HMPAO leucocyte scintigraphy in patients with infective endocarditis?

    International Nuclear Information System (INIS)

    Ellmann, A.; Rubow, S.M.; Erlank, P.; Reuter, H.

    2002-01-01

    Aim: Infective endocarditis is still an important disease in developing countries. Due to the difficult diagnosis, treatment is often delayed or inappropriate. A combination of clinical findings and echocardiography are used most often, but have a low sensitivity. As Tc-99m HMPAO labelled leucocyte scintigraphy is used routinely to evaluate patients with suspected infectious processes, it was postulated that this technique may also aid in the diagnosis of acute infective endocarditis in patients with rheumatic heart disease. Materials and Methods: Six patients who presented with clinical signs and symptoms of infective endocarditis, were referred for Tc-99m HMPAO labelled leucocyte scintigraphy. The white blood cells were labelled according to standard procedures. Whole body planar imaging, and single photon emission tomography of the chest area, with imaging at 30 minutes, 3 hours and 24 hours after the administration of the labelled leucocytes, were performed on all patients. Results: All the scintigrams were negative. No abnormal concentration of leucocytes could be detected in the region of the heart. This was in spite of clinical findings indicative of active infective endocarditis. Conclusion: Vegetations mainly consist of masses of clotted blood and blood cell debris, containing the causative organisms. Leucocytes do not play a major role in the pathologic process. Although only six patients were studied, it appears that Tc-99m HMPAO leucocyte scintigraphy is of no value in the evaluation of patients with infective endocarditis. A study after the administration of radiolabelled antibiotics may be of greater value and should be considered in these patients

  3. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  4. Functional impairments in patients with borderline personality disorders demonstrated by neurospect HMPAO Tc99 in basal conditions and under frontal activation

    International Nuclear Information System (INIS)

    Prado, Cristian; Mena G, Ismael; Correa, Maria del Pilar

    2000-01-01

    We study a sample of 18 patients in basal conditions and 31 patients with diagnosis of Borderline Personality Disorder (DSM-IV Criteria) during cortical activation by means of the Wisconsin card sorting test and assessing function/cerebral blood flow by means of HMPAO Tc 99m NeuroSPECT. The results of changes of cerebral blood flow are shown statistically in a parametric image expressing standard deviations above or below the means of a normative data base for the corresponding age of the patient. We consider only as having significance levels below 2 standard deviations of the normal means . Over this parametric map we project a matrix of Brodmann areas developed by our group in order to precisely localize the areas of abnormality observed. We express our results as percentages of the areas of Brodmann that demonstrates hypoperfusion and we compare the results in a population studied in basal conditions (n=18) and (n=31) during activation by means of the Wisconsin card sorting test. In our results we highlight, in order of importance areas of paradoxical hypoperfusion in conditions of activation versus basal measurements in anterior cyngulate gyrus (Area 24) in both hemispheres. This is followed in importance by Subgenual area (Area 25), area 40 and area 32 in the left hemisphere, and area 28 in the right hemisphere, then followed by area 28 and area 36 in the left hemisphere, area M* and area 44 in both hemispheres, and areas 32, 9 and 46 of Brodmann in the right hemisphere. We concluded that there is a dysfunctional correlation of frontal function in borderline personality disorder. Particularly noticeable is the lack of motivation when there are changes in plans and conduct, lack of pleasure and loss of the meaning of a task during the cortical stimulation. In particular, the Brodmann areas 24, 25 and 32, linked to motivation show a wider involvement when they are exposed to changes in planning and in coping strategies, as it happens during the Wisconsin Test

  5. Equivalent brain SPECT perfusion changes underlying therapeutic efficiency in pharmacoresistant depression using either high-frequency left or low-frequency right prefrontal rTMS.

    Science.gov (United States)

    Richieri, Raphaëlle; Boyer, Laurent; Padovani, Romain; Adida, Marc; Colavolpe, Cécile; Mundler, Olivier; Lançon, Christophe; Guedj, Eric

    2012-12-03

    Functional neuroimaging studies have suggested similar mechanisms underlying antidepressant effects of distinct therapeutics. This study aimed to determine and compare functional brain patterns underlying the antidepressant response of 2 distinct protocols of repetitive transcranial magnetic stimulation (rTMS). 99mTc-ECD SPECT was performed before and after rTMS of dorsolateral prefrontal cortex in 61 drug-resistant right-handed patients with major depression, using high frequency (10Hz) left-side stimulation in 33 patients, and low frequency (1Hz) right-side stimulation in 28 patients. Efficiency of rTMS response was defined as at least 50% reduction of the baseline Beck Depression Inventory score. We compared the whole-brain voxel-based brain SPECT changes in perfusion after rTMS, between responders and non-responders in the whole sample (pleft- and right-stimulation. Before rTMS, the left- and right-prefrontal stimulation groups did not differ from clinical data and brain SPECT perfusion. rTMS efficiency (evaluated on % of responders) was statistically equivalent in the two groups of patients. In the whole-group of responder patients, a perfusion decrease was found after rTMS, in comparison to non-responders, within the left perirhinal cortex (BA35, BA36). This result was secondarily confirmed separately in the two subgroups, i.e. after either left stimulation (p=0.017) or right stimulation (pbrain functional changes associated to antidepressive efficiency, consisting to a remote brain limbic activity decrease within the left perirhinal cortex. However, these results will have to be confirmed in a double-blind randomized trial using a sham control group. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Perfusion status of the stroke-like lesion at the hyperacute stage in MELAS.

    Science.gov (United States)

    Yeh, Hsu-Ling; Chen, Yen-Kung; Chen, Wei-Hung; Wang, Han-Cheng; Chiu, Hou-Chang; Lien, Li-Ming; Wei, Yau-Huei

    2013-02-01

    Hypoperfusion on single-photon emission computed tomography (SPECT) of the stroke-like lesion (SLL) at the hyperacute stage of mitochondrial encephalopathy with lactic acidosis and stroke-like episodes (MELAS) is considered to be a supportive evidence of the mitochondrial angiopathy theory. Our objectives were to examine whether other neuroimages, especially transcranial color-coded sonography (TCCS), done at the hyperacute stage of stroke-like episode (SLE) is consistent with hypoperfusion of the SLL. We reviewed the magnetic resonance imaging (MRI), SPECT, cerebral angiography, and TCCS of a patient with MELAS syndrome, all of which were performed at the hyperacute stage of one SLE. MRI on the 1st day post SLE showed right temporoparietal lesion with vasogenic edema. SPECT on the 2nd day showed focal decreased uptake of technetium-99m hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) in the same region, but cerebral angiography and TCCS on the 3rd day showed increased regional cerebral blood flow (rCBF) and distal arteriole dilation in the same region. TCCS can delineate increased rCBF of the SLL at the hyperacute stage of SLE. We propose that the discrepancy between the decreased (99m)Tc-HMPAO uptake and increased rCBF might be caused by mitochondrial dysfunction. The phenomenon of "hypoperfusion" on SPECT might be caused by cell dysfunction but not decreased rCBF. We suggest that SPECT can be complemented by angiography and TCCS in future studies to delineate the perfusion status of SLLs. Copyright © 2012 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  7. Determination of the cerebral dopamine-D2-receptor density by [sup 123]I-IBZM-SPECT in patients with Parkinson's disease. Bestimmung der zerebralen Dopamin-(D2)-Rezeptoren-Dichte mit Hilfe der [sup 123]Jod-IBZM-SPECT bei Patienten mit Morbus Parkinson

    Energy Technology Data Exchange (ETDEWEB)

    Hierholzer, J; Cordes, M; Barzen, G; Keske, U; Felix, R [Strahlenklinik und Poliklinik, Klinikum Rudolf Virchow, Berlin (Germany); Schelosky, L; Poewe, H [Neurologische Klinik und Poliklinik, Klinikum Rudolf Virchow, Berlin (Germany); Henkes, H [Inst. fuer Neuroradiologie, Univ. des Saarlandes, Homburg/Saar (Germany); Horowski, R [Schering AG, Berlin (Germany)

    1992-10-01

    An alteration of the dopaminergic nigrostriatal system is believed to be the main pathogenetic factor of Parkinson's disease (PD). We report on our initial results on the determination of the post-synapticdopamine-D2-receptor binding of [sup 123]I-IBZM in patients with PD. Drug-native patients showed a significantly higher IBZM binding in the basal ganglia as compared to patients on specific dopaminergic medication. We conclude that [sup 123]I-IBZM-SPECT is an extremely usuful tool for the evaluation of the functional state of cerebraldopamine-D2-receptors. (orig./DG).

  8. PLA-PEG nanocapsules radiolabeled with 99mTechnetium-HMPAO: release properties and physicochemical characterization by atomic force microscopy and photon correlation spectroscopy.

    Science.gov (United States)

    Pereira, Maira Alves; Mosqueira, Vanessa Carla Furtado; Vilela, José Mário Carneiro; Andrade, Margareth Spangler; Ramaldes, Gilson Andrade; Cardoso, Valbert Nascimento

    2008-01-01

    The present work describes the preparation, characterization and labelling of conventional and surface-modified nanocapsules (NC) with 99m Tc-HMPAO. The size, size distribution and homogeneity were determined by photon correlation spectroscopy (PCS) and zeta potential by laser doppler anemometry. The morphology and the structural organization were evaluated by atomic force microscopy (AFM). The stability and release profile of the NC were determined in vitro in plasma. The results showed that the use of methylene blue induces significant increase in the encapsulation efficiency of 99m Tc-HMPAO, from 24.4 to 49.8% in PLA NC and 22.37 to 52.93% in the case of PLA-PEG NC (P<0.05) by improving the complex stabilization. The average diameter of NC calculated by PCS varied from 216 to 323 nm, while the average diameter determined by AFM varied from 238 to 426 nm. The AFM analysis of diameter/height ratios suggested a greater homogeneity of the surface-modified PLA-PEG nanocapsules compared to PLA NC concerning their flattening properties. The in vitro release of the 99m Tc-HMPAO in plasma medium was faster for the conventional PLA NC than for the surface-modified NC. For the latter, 60% of the radioactivity remained associated with NC, even after 12h of incubation. The results suggest that the surface-modified 99m Tc-HMPAO-PLA-PEG NC was more stable against label leakage in the presence of proteins and could present better performance as radiotracer in vivo.

  9. Can perfusion SPECT aid CTPA interpretation?

    International Nuclear Information System (INIS)

    Gradinscak, D. J.; Roach, P.; Bailey, E.; Kueh, S.

    2009-01-01

    Full text:Objective: To determine whether fusion of perfusion SPECT and CTPA improves the diagnostic accuracy of CTPA. Methods: 35 patients with suspected PE who underwent both CTPA and SPECT V/Q within 48 hours were included. Of these, the majority (n=30) had PE as determined by the V/Q SPECT scan and the others (n=5) were negative for PE. The clinical reports of CTPA were reviewed and pulmonary emboli tabulated based on anatomical location. A second radiologist, blinded to the results of the clinical read and the V/Q SPECT scan, reviewed the CTPA with and without perfusion SPECT fusion for assistance. Results: A total 57 PE were reported on the clinical reports and 60 PE identified on the blinded read. Fused CTPA/perfursion SPECT images identified a further 5 PE not identified on the clinical read (8% increase) and 2 PE not identified on the blinded read (3% increase). The additional emboli detected resulted in a change in final diagnosis from PE negative to PE positive in 2 patients (6%) compared with the clinical read and 1 patient (3%) compared with the blinded read without SPECT fusion. Conclusion: Fused CTPA-SPECT perfusion improves the sensitivity of CTPA for the detection of PE in a small number of patients. Fused data may help guide the radiologist to identify sites of PE on CTPA.

  10. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    Science.gov (United States)

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  11. Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Engbers, Elsemiek M.; Mouden, Mohamed [Isala, Department of Cardiology, Zwolle (Netherlands); Isala, Department of Nuclear Medicine, Zwolle (Netherlands); Timmer, Jorik R.; Ottervanger, Jan Paul [Isala, Department of Cardiology, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala, Department of Nuclear Medicine, Zwolle (Netherlands)

    2017-01-15

    To investigate the impact of left bundle branch block (LBBB) on sequential single photon emission computed tomography (SPECT)/ CT imaging starting with stress-first SPECT. Consecutive symptomatic low- to intermediate-risk patients without a history of coronary artery disease (CAD) referred for SPECT/CT were included from an observational registry. If stress SPECT was abnormal, additional rest SPECT and, if feasible, coronary CT angiography (CCTA) were acquired. Of the 5,018 patients, 218 (4.3 %) demonstrated LBBB. Patients with LBBB were slightly older than patients without LBBB (65±12 vs. 61±11 years, p<0.001). Stress SPECT was more frequently abnormal in patients with LBBB (82 % vs. 46 %, p<0.001). After reviewing stress and rest images, SPECT was normal in 43 % of the patients with LBBB, compared to 77 % of the patients without LBBB (p<0.001). Sixty-four of the 124 patients with LBBB and abnormal stress-rest SPECT underwent CCTA (52 %), which could exclude obstructive CAD in 46 of the patients (72 %). Sequential SPECT/CT imaging starting with stress SPECT is not the optimal imaging protocol in patients with LBBB, as the majority of these patients have potentially false-positive stress SPECT. First-line testing using CCTA may be more appropriate in low- to intermediate-risk patients with LBBB. (orig.)

  12. Methods of gated-blood-pool-spect data processing

    International Nuclear Information System (INIS)

    Kosa, I.; Mester, J.; Tanaka, M.; Csernay, L.; Mate, E.; Szasz, K.

    1991-01-01

    Three techniques of gated SPECT were evaluated. The methods of Integral SPECT (ISPECT), enddyastole-endsystole SPECT (ED-ES SPECT) and Fourier SPECT were adapted and developed on the Hungarian nuclear medicine data processing system microSEGAMS. The methods are based on data reduction before back projection which results in processing times acceptable for the clinical routine. The clinical performance of the introduced techniques was tested in 10 patients with old posterior myocardial infarction and in 5 patients without cardiac disease. The left ventricular ejection faction determined by ISPECT correlated well with the planar values. The correlation coefficient was 0.89. The correlation coefficient of EF values determined by ED-ES SPECT and planar radionuclide ventriculography was lower (0.70). For the identification of left ventricular wall motion abnormalities ED-ES SPECT and Fourier SPECT exhibited a favourable performance, but ISPECT only moderate suitability. In the detection of regional phase delay Fourier-SPECT demonstrated higher sensitivity than the planar radionuclide ventriculography. (author) 4 refs.; 3 figs.; 2 tabs

  13. Testing the radiochemical purity of radiopharmaceuticals: application to {sup 99m}Tc-HMPAO; Controle de la purete radiochimique des radiopharmaceutiques: application au {sup 99m}Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Ait Ben Ali, S.; Darsin, D.; Rizzo, N.; Lours, S.; De Beco, V.; Dumont, A.; Goudou-Sinha, C.; Izembart, M.; Jourdain, J.R.; Lemercier, V.; Linsker, S.; Moati, F.; Piketty, M.L.; Schlageter, M.H.; Moretti, J.L. [Groupe de travail `Radiopharmaceutique - Ile de France` (France)

    1997-12-31

    The low stability of {sup 99m}Tc-HMPAO imposes to carry out the quality testing within the 15 minutes following the preparation. This study has the aim of comparing different methods of radiochemical purity determination (RP) of this radiopharmaceutical in order to validate a fast, reproducible, feasible technique, capable of separating the primary lipophilic {sup 99m}Tc-HMPAO (I) of impurities: hydrophilic secondary complex (II), TcO{sub 4}{sup -}, reduced and halyards Tc. The reference technique associating two thin-layer chromatographies (TLC), `C1` and `C2`, has been compared with a TLC `W` technique and with liquid-liquid extraction `E` technique: C1 - stationary phase, ITLC Silica gel/mobile phase, Butanone-2; C2 - stationary phase, ITLC Silica gel/mobile phase, 0.9% NaCl; W - stationary phase, Papier Whatman n{sup o} 1/mobile phase, Ether; E - extraction with ethyls acetate /0.9% NaCl (1/1 v/v). The `C1` chromatography allows isolating the reduced Tc and the complex II, the `C2` chromatography does the same with TcO{sub 4}{sup -} but it requires too long techniques (20 min.). The `W` and `E` techniques are rapid, reproducible and allow to separate the complex I from the other impurities without discrimination. However, as their results depend upon the deposited quantity of sampling, an optimization and standardization of the techniques are necessary. A forth technique by chromatography on Sep-Pak column is to be evaluated

  14. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  15. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Kasper, S.; Gruenwald, F.; Walter, H.; Klemm, E.; Podreka, I.; Biersack, H.J.

    1994-01-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [de

  16. Cerebral blood flow SPECT may be helpful in establishing the diagnosis of progressive supranuclear palsy and corticobasal degeneration

    International Nuclear Information System (INIS)

    Slawek, J.; Lass, P.; Derejko, M.; Dubaniewicz, M.

    2001-01-01

    We present 4 cases, which illustrate the usefulness of neuroimaging studies in atypical forms of Parkinsonism. Progressive Supranuclear Palsy (PSP) and Corticobasal Degeneration (CBD) are rare neurodegenerative progressive disorders of the central nervous system of unknown cause. The clinical accuracy in this diagnosis is not very high even in centres specialising in movement disorders. Functional imaging can be helpful in diagnosing PSP and CBD. We present the results of cerebral blood flow (CBF) SPECT scanning in 2 patients with PSP and 2 patients with CBD. This was performed using a triple-head gammacamera and 99m Tc-HMPAO. In PSP patients a diffuse frontal perfusion deficit was seen, eventually with striatal and occipital hypoperfusion. CT/MRI was either normal or showed a diffuse cortical-subcortical atrophy. In CBD patients left fronto-parieto-temporal cortex and a striatal hypoperfusion were shown. CT scanning was normal in one case and showed an asymmetrical temporo-parietal atrophy in second one. The pattern of diffuse frontal perfusions deficit in PSP and asymmetrical, contralateral to symptoms of CBD, cortico-subcortical hypoperfusion may be helpful in establishing the correct diagnosis. (author)

  17. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  18. Quantitation of cerebral blood flow using HMPAO tomography

    International Nuclear Information System (INIS)

    Bruyant, P.; Mallet, J.J.; Sau, J.; Teyssier, R.; Bonmartin, A.

    1997-01-01

    A method has been developed to quantitate regional cerebral blood flow (rCBF) using 99m Tc-HMPAO. It relies on the application of the bolus distribution principle. The rCBF is determined using compartmental analysis, by measuring the amount of tracer retained in the parenchyma and the input function. The values for blood: brain partition coefficient and for the conversion rate from the lipophilic to the hydrophilic form of the tracer are taken from the literature. Mean values for rCBF in eight patients are 41.1 ± 6.4 et 25.6 ± 5.8 mL.min -1 for the grey matter and for the white matter respectively (mean±standard deviation). This method allows to quantitate rCBF with one SPET scan and one venous blood sample. (authors)

  19. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  20. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  1. Clinical applications of single photon emission tomography in neuromedicine. Pt. 2. Dementia, psychotic disorders, inflammation, trauma; Klinische Anwendungen der Single-Photon-Emissionstomographie in der Neuromedizin. T. 2. Dementielle Erkrankungen, Psychosen, Entzuendungen, Schaedelhirntrauma

    Energy Technology Data Exchange (ETDEWEB)

    Bartenstein, P.; Gruenwald, F.; Kuwert, T.; Tatsch, K.; Sabri, O.; Benkert, O.; Fahlbusch, R.; Gruender, G.; Herholz, K.; Weiller, C. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2000-12-01

    This article gives in his second part a critical review of the clinical applications of SPECT with perfusion markers and receptor ligands in dementing disorders and psychosis. In addition this review discusses clinical applications of SPECT investigations with perfusion markers in inflammatory diseases of the central nervous system and in brain trauma. (orig.) [German] Die vorliegende Arbeit vermittelt in ihrem zweiten Teil eine kritisch wertende Uebersicht ueber die klinischen Anwendungsmoeglichkeiten von SPECT-Untersuchungen mit Perfusionsmarkern und Rezeptorliganden bei dementiellen Erkrankungen sowie affektiven und schizophrenen Psychosen. Darueber hinaus werden in dieser Uebersicht Anwendungen von SPECT-Untersuchungen mit Perfusionsmarkern bei Fragestellungen im Rahmen von Entzuendungen des zentralen Nervensystems und bei Schaedelhirntraumata diskutiert. (orig.)

  2. Abdominal scintigraphy using 99mTc-HMPAO-labelled leucocytes in patients with seronegative spondylarthropathies without clinical evidence of inflammatory bowel disease

    International Nuclear Information System (INIS)

    Alonso, J.C.; Lopez-Longo, F.J.; Lampreave, J.L.; Gonzalez, C.M.; Vegazo, O.; Carreno, L.; Almoguera, I.

    1996-01-01

    Abdominal scintigraphy with technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO)-labelled leucocytes is an excellent tool for evaluating disease extent and activity of intestinal lesions in patients with inflammatory bowel disease (IBD). In some cases of seronegative spondylarthropathies (SSp), IBD may remain subclinical. The aim of this study was to evaluate the presence of positive abdominal scintigraphy in patients with SSp and without clinical symptoms or signs of IBD. To this end we studied 32 patients with active SSp (European Spondylarthropathy Study Group 1991 criteria) without clinical evidence of IBD (eight had ankylosing spondylitis, four psoriatic arthritis, three reactive arthritis an 17 undifferentiated SSp) and 11 controls without SSp. All SSp and control patients received similar doses of non-steroidal anti-inflammatory drugs (NSAIDs). Abdominal scintigraphic images were obtained at 30 and 120 min after re-injection of 99m Tc-HMPAO-labelled leucocytes. The 99m Tc-HMPAO-labelled leucocyte scan was positive in 17 patients with SSp (53.1%) (six with ankylosing spondylitis, three with psoriatic arthritis, two with reactive arthritis and six with undifferentiated SSp). Fourteen patients scored from 2 to 4 on the intensity of uptake scale. The colon and terminal ileum were predominantly involved. Axial involvement was more frequent in patients with a positive scan than in patients with negative results (P 99m Tc-HMPAO-labelled leucocyte scan shows increased uptake among patients with SSp without evidence of IBD. These findings provide new evidence linking SSp with intestinal inflammation and suggest that in some cases a bowel-related process could contribute to the development of SSp. Long-term follow-up studies with more patients are necessary to evaluate the diagnostic and therapeutic implications of these results. (orig.). With 3 figs., 3 tabs

  3. Measurement of cerebral perfusion after zolpidem administration in the baboon model.

    Science.gov (United States)

    Clauss, R P; Dormehl, I C; Oliver, D W; Nel, W H; Kilian, E; Louw, W K

    2001-01-01

    A recent report showed that zolpidem (CAS 82626-48-0) can lead to the arousal of a semi-comatosed patient. Zolpidem is clinically used for the treatment of insomnia. It belongs to the imidazopyridine chemical class and is a non benzodiazepine drug. It illicits its pharmacological action via the GABA receptor system through stimulation of particularly the omega 1 receptors. In this study, the effect of zolpidem on brain perfusion was examined by 99mTc hexamethyl-propylene amine oxime (HMPAO) split dose brain SPECT on four normal baboons and in one baboon with abnormal neurological behaviour. The global and regional brain perfusion was not significantly affected in the normal brains. In some regions of the abnormal baboon brain, however, there was a disproportionate increase in perfusion after zolpidem.

  4. Clinical evaluation of SPECT in cerebrovascular disease

    International Nuclear Information System (INIS)

    Oshibuchi, Masao; Satoh, Mitsutaka; Kanda, Tetsuro; Nishi, Fumiaki; Yamane, Kanji; Fujimatsu, Masahiko; Edamitsu, Satoshi; Anno, Yasuro; Ohtake, Hisashi.

    1989-01-01

    In 131 patients with cerebrovascular disease, regional cerebral blood flow were determined by 123 I-IMP (N-isopropyl ( 123 I)-iodoamphetamine) or 99m Tc-HM-PAO ( 99m Tc (d, 1)-hexamethyl propyleneamine oxime) SPECT and findings were compared with those of X-CT or MRI. The perfusion deficit detected by SPECT was larger than the deficit by X-CT or MRI in every case. The perfusion deficit area was more clearly demonstrated by SPECT than by X-CT or MRI in patients with acute cerebral infarction. The hypoperfusion area determined by 123 I-IMP SPECT was wider than that by 99m Tc-HM-PAO SPECT. The crossed cerebellar diaschisis was observed in 56 out of 131 cases (43%). The results of operation were quantitatively evaluated by 123 I-IMP SPECT in 25 patients. (author)

  5. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    International Nuclear Information System (INIS)

    Lee, Sang Kun; Lee, Dong Soo

    2003-01-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test

  6. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Kun; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test.

  7. A technique for manual definition of an irregular volume of interest in single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fleming, J.S.; Kemp, P.M.; Bolt, L.

    1999-01-01

    A technique is described for manually outlining a volume of interest (VOI) in a three-dimensional SPECT dataset. Regions of interest (ROIs) are drawn on three orthogonal maximum intensity projections. Image masks based on these ROIs are backprojected through the image volume and the resultant 3D dataset is segmented to produce the VOI. The technique has been successfully applied in the exclusion of unwanted areas of activity adjacent to the brain when segmenting the organ in SPECT imaging using 99m Tc HMPAO. An example of its use for segmentation in tumour imaging is also presented. The technique is of value for applications involving semi-automatic VOI definition in SPECT. (author)

  8. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Grova, C [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Jannin, P [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Biraben, A [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Buvat, I [INSERM U494, CHU Pitie Salpetriere, Paris (France); Benali, H [INSERM U494, CHU Pitie Salpetriere, Paris (France); Bernard, A M [Service de Medecine Nucleaire, Centre Eugene Marquis, Rennes (France); Scarabin, J M [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Gibaud, B [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France)

    2003-12-21

    Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were

  9. Chronic motor cortex stimulation in patients with advanced Parkinson's disease and effects on striatal dopaminergic transmission as assessed by 123I-FP-CIT SPECT: a preliminary report.

    Science.gov (United States)

    Di Giuda, Daniela; Calcagni, Maria L; Totaro, Manuela; Cocciolillo, Fabrizio; Piano, Carla; Soleti, Francesco; Fasano, Alfonso; Cioni, Beatrice; Bentivoglio, Anna R; Giordano, Alessandro

    2012-09-01

    The objective of this study was to assess striatal dopamine transporter availability in patients with advanced Parkinson's disease (PD) before and after 13 months of unilateral extradural motor cortex stimulation (EMCS) with [123I]N-ω-fluoropropyl-2-β-carbo-methoxy-3-β-(4-iodophenyl)nortropane single photon emission computed tomography (123I-FP-CIT SPECT). Six PD patients (five women and one man, aged 63.2 ± 5.6 years) underwent 123I-FP-CIT SPECT and clinical evaluation [Unified Parkinson's Disease Rating Scale (UPDRS) and Parkinson's Disease Quality of Life Scale (PDQL)] preoperatively, 8 and 13 months after EMCS. Striatum-to-occipital cortex, caudate-to-occipital cortex and putamen-to-occipital cortex 123I-FP-CIT uptake ratios were calculated using the region of interest method. Total and part III UPDRS scores significantly decreased at 8 and 13 months after stimulation (P=0.02 and 0.04, respectively); UPDRS part II and PDQL scores improved after 13 months (P=0.02 and 0.04, respectively). No significant differences in 123I-FP-CIT uptake ratios between baseline and follow-up were found in the examined regions. However, a progressive reduction in 123I-FP-CIT uptake ratios in the striatum contralateral to the implant was found. In contrast, no further decrease in 123I-FP-CIT uptake ratios was detected in the striatum ipsilateral to the implant. There were no correlations between changes in 123I-FP-CIT uptake ratios with disease duration, changes in medication dosage and motor UPDRS scores. Despite a small but highly selected sample of advanced PD patients, our results showed that no further dopamine transporter reduction occurred in the striatum ipsilateral to the implant side. This finding could lead to the hypothesis that EMCS might elicit a 'neuroprotective' effect, as suggested by significant clinical benefits.

  10. Quantitation of dopamine transporter blockade by methylphenidate: first in vivo investigation using [123I]FP-CIT and a dedicated small animal SPECT

    International Nuclear Information System (INIS)

    Nikolaus, Susanne; Wirrwar, Andreas; Antke, Christina; Arkian, Shahram; Mueller, Hans-Wilhelm; Larisch, Rolf; Schramm, Nils

    2005-01-01

    The aim of this study was to investigate the feasibility of assessing dopamine transporter binding after treatment with methylphenidate in the rat using a recently developed high-resolution small animal single-photon emission computed tomograph (TierSPECT) and [ 123 I]FP-CIT. [ 123 I]FP-CIT was administered intravenously 1 h after intraperitoneal injection of methylphenidate (10 mg/kg) or vehicle. Animals underwent scanning 2 h after radioligand administration. The striatum was identified by superimposition of [ 123 I]FP-CIT scans with bone metabolism and perfusion scans obtained with 99m Tc-DPD and 99m Tc-tetrofosmin, respectively. As these tracers do not pass the blood-brain barrier, their distribution permits the identification of extracerebral anatomical landmarks such as the orbitae and the harderian glands. The cerebellum was identified by superimposing [ 123 I]FP-CIT scans with images of brain perfusion obtained with 99m Tc-HMPAO. Methylphenidate-treated animals and vehicle-treated animals yielded striatal equilibrium ratios (V '' 3 ) of 0.24±0.26 (mean ± SD) and 1.09±0.42, respectively (ttest, two-tailed, p '' 3 values amounted to 0.05±0.28 (methylphenidate) and 0.3±0.39 (saline, p=0.176). This first in vivo study of rat dopamine transporter binding after pre-treatment with methylphenidate showed a mean reduction of 78% in striatal [ 123 I]FP-CIT accumulation. The results can be interpreted in terms of a pharmacological blockade in the rat striatum and show that in vivo quantitation of dopamine transporter binding is feasible with [ 123 I]FP-CIT and the TierSPECT. This may be of future relevance for in vivo investigations on rat models of attention deficit/hyperactivity disorder. Furthermore, our findings suggest that investigations in other animal models, e.g. of Parkinson's and Huntington's disease, may be feasible using SPECT radioligands and small animal imaging systems. (orig.)

  11. Altered cerebral blood flow in chronic neck pain patients but not in whiplash patients: a 99mTc-HMPAO rCBF study.

    Science.gov (United States)

    Sundström, Torbjörn; Guez, Michel; Hildingsson, Christer; Toolanen, Göran; Nyberg, Lars; Riklund, Katrine

    2006-08-01

    A cross-sectional study to investigate regional cerebral blood flow (rCBF) in patients with chronic whiplash syndrome and chronic neck pain patients without previous history of trauma along with a healthy control group. Chronic neck pain is a common disorder and a history of cervical spine injury including whiplash trauma constitute a risk factor for persistent neck pain. The aetiology of the late whiplash syndrome is unknown with no specific diagnostic criteria based on imaging, physiological, or psychological examination. Earlier studies indicate a parieto-occipital hypoperfusion but it is unclear if the hypoperfusion represents a response to chronic pain. The rCBF was monitored in 45 patients with chronic neck pain: 27 cases with chronic whiplash syndrome and 18 age and gender matched cases with non-traumatic chronic neck pain. The rCBF was estimated with single-photon emission computed tomography (SPECT) using technetium-99m hexamethylpropylene amine oxime (HMPAO). The non-traumatic patients displayed rCBF changes in comparison with the whiplash group and the healthy control group. These changes included rCBF decreases in a right temporal region close to hippocampus, and increased rCBF in left insula. The whiplash group displayed no significant differences in rCBF in comparison with the healthy controls. The present study suggests different pain mechanisms in patients with chronic neck pain of non-traumatic origin compared to those with chronic neck pain due to a whiplash trauma.

  12. Neuro-functional alteration in disorders of the encourage they cause with conducts self-mutilations study of cerebral regional perfusion starting from the technique of Neuro-SPECT Tc99-HMPAO

    International Nuclear Information System (INIS)

    Mena, Ismael; Correa, Rodrigo; Nader, Armando

    2007-01-01

    We report NeuroSPECT findings in mood disorders, including bipolar disorder, major depression and self-mutilation. We compare results in 29 patients with bipolar disorder complicated by self-mutilation, a group of 20 patients with bipolar disorder uncomplicated and 22 patients with mayor depression uncomplicated by self-mutilation. Among the NeuroSPECT findings we report the association of mood disorders and self-mutilation with hyper perfusion of the anterior-dorsal-ventral segment of both thalami concomitant with hypoperfusion in perilimbic cortex, namely areas 32, 24 (anterior cingulate gyrus) and 23 of Brodmann. Multiple reports in the literature relate both, in animals and man, self-mutilation with phenomena of hypoalghesia, anesthesia, or dysestesias and are the basis for our hypothesis linking dysfunction of limbic-thalamic circuits, associated with nocioceptive fibers, somato-psychic consciousness and self-mutilation phenomena

  13. Dementia due to normal-pressure hydrocephalus by single photon emission computer tomography

    International Nuclear Information System (INIS)

    Borbely, K.; Kordas, M.; Kadar, K.; Nyary, I.

    2002-01-01

    Aims: Once a diagnosis of dementia is established, the irreversible and degenerative types of dementia should be differentiated from those with potentially treatable causes. Normal-pressure hydrocephalus (NPH) is a reversible and poorly understood cause of mental impairment. Ventricular enlargement as registered by Computer Tomography (CT) or Magnetic Resonance Imaging (MRI) might be neurologically stable or progressive in nature. CT/MRI can display the exact size and shape of the ventricles. However, either CT or MRI cerebrospinal fluid (CSF) flow studies are unable to predict the response to shunt operation. The purpose of this study was to determine the role of 99m Tc-HMPAO regional cerebral blood flow (rCBF) SPECT combined with 99m Tc-DTPA CSF-SPECT in the preoperative evaluation of patients with chronic hydrocephalus. Methods: 103 consecutive studies were carried out where patient management was of concern with a standard technique for each patient (555 MBq 99mTc-HMPAO/ECD; 250 MBq 99mTc-DTPA, 1/3/6/24 h planar, 6/24h SPECT; double head ADAC SPECT camera). RCBF SPECT studies were analysed visually and by a special region of interests (ROIs) program. Circular ROIs were placed over the striatum, thalamus, white matter, frontal, temporal, parietal, occipital cortex, and cerebellum. ROIs were normalized to the whole brain average. The statistical analysis was considered significant at P≤0.05. The results of combined SPECT studies were correlated with CT/MRI, and clinical findings. Results: In 75 cases the hydrocephalus appeared to be communicating. In 19 cases there was a contradiction between the results of CT/MRI and CSF SPECT. 67 ventriculoperitoneal shunt implantations were carried out on the basis of combined SPECT studies. In 67 patients the rCBF SPECT except for hydrocephalus, demonstrated decreased rCBF in the periventricular white matter, thalamus and basal ganglia. There were additional bilateral rCBF abnormalities in the frontal or fronto

  14. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  15. Comparison of simultaneous [sup 99m]Tc-HMPAO and [sup 111]In oxine labelled white cell scans in the assessment of inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Allan, R.A.; Bassingham, S.; Lazarus, C.; Clarke, S.E.M.; Fogelman, I. (Guy' s Hospital, London (United Kingdom). Dept. of Nuclear Medicine); Sladen, G.E. (Guy' s Hospital, London (United Kingdom). Dept. of Gastroenterology)

    1993-03-01

    Forty-seven patients, 29 with chronic inflammatory bowel disease (IBD) and 18 with presumed irritable bowel syndrome, including one with uncomplicated diverticular disease, were studied with simultaneous technetium-99m hexamethylpropylene amine oxime and indium-III oxine labelled leucocyte scans performed at 1, 3 and 24 h. Twenty-seven patients with IBD had active disease as judged by clinical and laboratory criteria and all of these had positive scans with both agents. No false positive studies were obtained. The 1-h [sup 99m]Tc-HMPAO WBC scans showed the same distribution to disease as the 3-h [sup 111]-In WBC scans, with no difference in intensity (P<0.92); they showed more extensive disease (P<0.02) and more intense uptake (P<0.001) than did the 1-h [sup 111]-In scans. The 3-h [sup 99m]Tc-HMPAO WBC scans showed more extensive disease (P<0.002), with greater intensity (P<0.0005), than did the 3-h [sup 111]In WBC scans. Physiological bowel activity on 3-h [sup 99m]Tc-HMPAO WBC scans was present in 12 patients but was faint and did not interfere with assessment of disease extent and activity. It is concluded that in terms of isotope availability, radiation dosimetry and image quality, [sup 99m]Tc-HMPAO is the agent of choice in detecting active IBD, with localization of disease possible at 1-h after re-injection and optimal resolution and definition of disease extent at 3 h. A negative scan reliably excludes active disease. (orig.).

  16. Testing the radiochemical purity of radiopharmaceuticals: application to 99mTc-HMPAO

    International Nuclear Information System (INIS)

    Ait Ben Ali, S.; Darsin, D.; Rizzo, N.; Lours, S.; De Beco, V.; Dumont, A.; Goudou-Sinha, C.; Izembart, M.; Jourdain, J.R.; Lemercier, V.; Linsker, S.; Moati, F.; Piketty, M.L.; Schlageter, M.H.; Moretti, J.L.

    1997-01-01

    The low stability of 99m Tc-HMPAO imposes to carry out the quality testing within the 15 minutes following the preparation. This study has the aim of comparing different methods of radiochemical purity determination (RP) of this radiopharmaceutical in order to validate a fast, reproducible, feasible technique, capable of separating the primary lipophilic 99m Tc-HMPAO (I) of impurities: hydrophilic secondary complex (II), TcO 4 - , reduced and halyards Tc. The reference technique associating two thin-layer chromatographies (TLC), 'C1' and 'C2', has been compared with a TLC 'W' technique and with liquid-liquid extraction 'E' technique: C1 - stationary phase, ITLC Silica gel/mobile phase, Butanone-2; C2 - stationary phase, ITLC Silica gel/mobile phase, 0.9% NaCl; W - stationary phase, Papier Whatman n o 1/mobile phase, Ether; E - extraction with ethyls acetate /0.9% NaCl (1/1 v/v). The 'C1' chromatography allows isolating the reduced Tc and the complex II, the 'C2' chromatography does the same with TcO 4 - but it requires too long techniques (20 min.). The 'W' and 'E' techniques are rapid, reproducible and allow to separate the complex I from the other impurities without discrimination. However, as their results depend upon the deposited quantity of sampling, an optimization and standardization of the techniques are necessary. A forth technique by chromatography on Sep-Pak column is to be evaluated

  17. Motor activation SPECT for the neurosurgical diseases. Clinical application

    International Nuclear Information System (INIS)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  18. Motor activation SPECT for the neurosurgical diseases. Clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Noguchi, Hiroshi; Kawaguchi, Shoichiro; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-08-01

    We evaluated and analyzed the motor activation single photon emission computed tomography (M-SPECT) findings on patients with ischemic cerebrovascular diseases (CVD). The M-SPECT studies were carried out on 91 patients with ischemic cerebrovascular diseases. The M-SPECT study was performed using the finger opposition task in each case. The SPECT images were superimposed on the magnetic resonance images (MRIs) for each case using Image Fusion Software. The result of the M-SPECT was expressed as positive or negative. The cases with a marked increase of blood flow in the sensorio-motor cortex after the finger opposition task were categorized as positive, and those cases showing no marked increase of blood flow were categorized as negative. Among the 91 cases examined, 53 (58%) were categorized as positive in the M-SPECT study. Among the negative M-SPECT cases treated with revascularization surgery, there were some cases showing positive M-SPECT results postoperatively. The cases without any revascularization surgery did not change the M-SPECT findings in each during the follow-up period. The M-SPECT procedure for examining intracranial lesions could provide the cortical localization of the motor function. The M-SPECT procedure in the ischemic CVDs contributes to knowledge about the choices of treatment and the evaluation of the treatment result. (author)

  19. In vivo SPECT reporter gene imaging of regulatory T cells.

    Directory of Open Access Journals (Sweden)

    Ehsan Sharif-Paghaleh

    Full Text Available Regulatory T cells (Tregs were identified several years ago and are key in controlling autoimmune diseases and limiting immune responses to foreign antigens, including alloantigens. In vivo imaging techniques including intravital microscopy as well as whole body imaging using bioluminescence probes have contributed to the understanding of in vivo Treg function, their mechanisms of action and target cells. Imaging of the human sodium/iodide symporter via Single Photon Emission Computed Tomography (SPECT has been used to image various cell types in vivo. It has several advantages over the aforementioned imaging techniques including high sensitivity, it allows non-invasive whole body studies of viable cell migration and localisation of cells over time and lastly it may offer the possibility to be translated to the clinic. This study addresses whether SPECT/CT imaging can be used to visualise the migratory pattern of Tregs in vivo. Treg lines derived from CD4(+CD25(+FoxP3(+ cells were retrovirally transduced with a construct encoding for the human Sodium Iodide Symporter (NIS and the fluorescent protein mCherry and stimulated with autologous DCs. NIS expressing self-specific Tregs were specifically radiolabelled in vitro with Technetium-99m pertechnetate ((99mTcO(4(- and exposure of these cells to radioactivity did not affect cell viability, phenotype or function. In addition adoptively transferred Treg-NIS cells were imaged in vivo in C57BL/6 (BL/6 mice by SPECT/CT using (99mTcO(4(-. After 24 hours NIS expressing Tregs were observed in the spleen and their localisation was further confirmed by organ biodistribution studies and flow cytometry analysis. The data presented here suggests that SPECT/CT imaging can be utilised in preclinical imaging studies of adoptively transferred Tregs without affecting Treg function and viability thereby allowing longitudinal studies within disease models.

  20. A study on measurement of the regional cerebral blood flow using autoradiographic method in moyamoya disease

    International Nuclear Information System (INIS)

    Sasaki, Tomohiro; Kiya, Katsuzo; Yuki, Kiyoshi; Kawamoto, Hitoshi; Mizoue, Tatsuya; Kiura, Yoshihiro; Uozumi, Tohru; Ikawa, Fusao

    1997-01-01

    Development of Autoradiographic method (ARG) has provided measurement of cerebral blood flow in moyamoya disease. We evaluate a cerebral vasodilatory capacity (CVC) for moyamoya disease using ARG method. We used 5 patients with moyamoya disease as a candidate for measurement of the cerebral blood flow (CBF) who admitted to Hiroshima Prefectural Hospital during the past one year. There were 3 patients in an adult age and 2 patients in a young age. We tried to measure the regional CBF (rCBF) using ARG method which was a easy way to estimate the rCBF on SPECT. The CVC was calculated from the difference of the rCBF between resting SPECT and Diamox-loading SPECT. Results were as follows; Reactivity of cerebral vessels to CO 2 loading and CVC weakened in moyamoya disease. The rCBF and CVC in the territories of anterior and middle cerebral arteries reduced in comparison with those in the area supplied by the posterior cerebral artery. The CVC at the treated side with surgical reconstruction recovered somewhat in an adult type. From these results, measurement of CBF using ARG method seems to be useful for evaluation of the CVC in moyamoya disease. (author)

  1. Investigations of the cerebral blood flow by means of nuclear medicine in polycythemia vera rubra. Untersuchungen des zerebralen Blutflusses bei Polyzythaemia vera rubra mit nuklearmedizinischen Methoden

    Energy Technology Data Exchange (ETDEWEB)

    Franke, W.G. (Medizinische Akademie Dresden, Klinik und Poliklinik fuer Nuklearmedizin (Germany)); Unger, L. (Medizinische Akademie Dresden, Klinik und Poliklinik fuer Psychiatrie und Neurologie (Germany)); Mueller, J. (Medizinische Akademie Dresden, Klinik und Poliklinik fuer Psychiatrie und Neurologie (Germany))

    1993-04-01

    P.v. represents a ''clinical model'' of diagnostic radionuclide application to evaluate the total and regional perfusion of brain. 107 polycythemians treated by or provided for radiophosphorus were studied by neurologic methods as EEG e.g. and with XCT if necessary. These studies were accomplished repeatedly in 62% of the surveyed patients. We found disturbed perfusion in brain: 32, diminuation of blood flow in vertebral-basilar region: 8, polyneuropathies: 27, psychic abnormalities: 60. Therapeutic effects became ascertained in 34% of hemipareses. The majority of polycythemic patients let recognize a regression of subjective complaints. The diagnostic informations obtained by radionuclide methods were compared to clinical and neurologic results as mentioned above. A good correlation could observed from radionuclide angiography, [sup 133]Xe-studies of total and regional cerebral perfusion and HMPAO-SPECT to neurologic and radiological findings. 66% of studied patients showed abnormal radioactivity distribution at static scintigrams. Disturbances of cerebral perfusion were seen in 20 from 26 patients if radionuclide angiography was used. Especially the inflow to cerebral vessels was found retarded by this method. Even in 3 neurologically inconspicuous persons the cerebral perfusion was restricted. Only 5 patients without signs of decreased flow could be seen. In 9 of 10 cases studied using [sup 133]Xenon referred to diminuation of cerebral perfusion. Both dynamic methods showed changes in perfusion depending from time course. Numerous localized defects of vascularization were detected by SPECT in some corresponding with neurologic symptoms in other patients differing from these ones. (orig./MG)

  2. Quantitation of dopamine transporter blockade by methylphenidate: first in vivo investigation using [{sup 123}I]FP-CIT and a dedicated small animal SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Nikolaus, Susanne; Wirrwar, Andreas; Antke, Christina; Arkian, Shahram; Mueller, Hans-Wilhelm; Larisch, Rolf [Heinrich-Heine University, Clinic of Nuclear Medicine, Duesseldorf (Germany); Schramm, Nils [Research Center Juelich, Central Laboratory for Electronics, Juelich (Germany)

    2005-03-01

    The aim of this study was to investigate the feasibility of assessing dopamine transporter binding after treatment with methylphenidate in the rat using a recently developed high-resolution small animal single-photon emission computed tomograph (TierSPECT) and [{sup 123}I]FP-CIT. [{sup 123}I]FP-CIT was administered intravenously 1 h after intraperitoneal injection of methylphenidate (10 mg/kg) or vehicle. Animals underwent scanning 2 h after radioligand administration. The striatum was identified by superimposition of [{sup 123}I]FP-CIT scans with bone metabolism and perfusion scans obtained with {sup 99m}Tc-DPD and {sup 99m}Tc-tetrofosmin, respectively. As these tracers do not pass the blood-brain barrier, their distribution permits the identification of extracerebral anatomical landmarks such as the orbitae and the harderian glands. The cerebellum was identified by superimposing [{sup 123}I]FP-CIT scans with images of brain perfusion obtained with {sup 99m}Tc-HMPAO. Methylphenidate-treated animals and vehicle-treated animals yielded striatal equilibrium ratios (V''{sub 3}) of 0.24{+-}0.26 (mean {+-} SD) and 1.09{+-}0.42, respectively (ttest, two-tailed, p<0.0001). Cortical V''{sub 3} values amounted to 0.05{+-}0.28 (methylphenidate) and 0.3{+-}0.39 (saline, p=0.176). This first in vivo study of rat dopamine transporter binding after pre-treatment with methylphenidate showed a mean reduction of 78% in striatal [{sup 123}I]FP-CIT accumulation. The results can be interpreted in terms of a pharmacological blockade in the rat striatum and show that in vivo quantitation of dopamine transporter binding is feasible with [{sup 123}I]FP-CIT and the TierSPECT. This may be of future relevance for in vivo investigations on rat models of attention deficit/hyperactivity disorder. Furthermore, our findings suggest that investigations in other animal models, e.g. of Parkinson's and Huntington's disease, may be feasible using SPECT radioligands and

  3. Applications of cerebral SPECT

    Energy Technology Data Exchange (ETDEWEB)

    McArthur, C., E-mail: claire.mcarthur@nhs.net [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom); Jampana, R.; Patterson, J.; Hadley, D. [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2011-07-15

    Single-photon emission computed tomography (SPECT) can provide three-dimensional functional images of the brain following the injection of one of a series of radiopharmaceuticals that crosses the blood-brain barrier and distributes according to cerebral perfusion, neurotransmitter, or cell density. Applications include differentiating between the dementias, evaluating cerebrovascular disease, preoperative localization of epileptogenic foci, diagnosing movement disorders, and evaluation of intracerebral tumours, while also proving a useful research tool. Unlike positronemission tomography (PET), SPECT imaging is widely available and can be performed in any department that has access to a rotating gamma camera. The purpose of this review is to demonstrate the utility of cerebral SPECT and increase awareness of its role in the investigation of neurological and psychiatric disorders.

  4. Brain single photon emission computed tomography in neonates

    International Nuclear Information System (INIS)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.

    1989-01-01

    This study was designed to rate the clinical value of [ 123 I]iodoamphetamine (IMP) or [ 99m Tc] hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that [ 123 I]IMP or [ 99m Tc]HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit

  5. Radiopharmaceuticals for SPECT cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Chernov, V. I., E-mail: chernov@oncology.tomsk.ru; Medvedeva, A. A., E-mail: tickayaAA@oncology.tomsk.ru; Zelchan, R. V., E-mail: r.zelchan@yandex.ru; Sinilkin, I. G., E-mail: sinilkinig@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Stasyuk, E. S.; Larionova, L. A. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Slonimskaya, E. M.; Choynzonov, E. L. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  6. SPECT of the brain: Present and future

    International Nuclear Information System (INIS)

    Fazio, F.; Lenzi, G.L.

    1986-01-01

    In both PET and SPECT, most of the studies and the models have been addressed to two organs: brain and heart. So far, brain has certainly been investigated more. The several comparisons between planar scintigraphy and SPECT, between X-ray TCT and SPECT, and also between PET and SPECT, have tended to consider SPECT a cheap but scarcely useful tool for a nuclear medicine section. Again the authors feel that this is due to the fact that SPECT is really a ''physiological tomography'', with little known about its physiology or how it is measured. Thus the present state of the art of SPECT of the brain is characterized by a collection of data and reports on brain imaging and by a slowly growing basic understanding of the utilized modes. The introduction of a new brain-imaging radiopharmaceutical is immediately signaled by its ''first clinical application'' without parallel studies on the kinetics, the metabolic degradation, and the real suitability of the molecule as a tracer for measurement of regional CBF. Only a few attempts seek to narrow this discussion between clinic and biology, and the authors like to emphasize the need for nuclear medicine people to dedicate more time and effort

  7. Clinical evaluation of stress thallium spect in ischemic heart disease

    International Nuclear Information System (INIS)

    Sui, Osamu; Kimura, Nazuna; Soeki; Takeshi; Takeichi, Naoki; Shinohara, Hisanori; Tamura, Yoshiyuki; Fukuda, Nobuo

    1997-01-01

    Thallium SPECT was performed in patients with significant coronary artery stenosis, 67 cases were after maximal exercise and 74 cases were during coronary vasodilation induced by ATP (adenosine triphosphate) infusion. In patients suspected of angina pectoris, the sensitivity, specificity and predictive accuracy for detection of coronary artery disease (CAD) were 88%, 78% and 82% for exercise SPECT, and 100%, 72% and 84% for ATP SPECT studies, respectively. In patients with old myocardial infarction, these were 73%, 100% and 88% for exercise SPECT and 71%, 100% and 81% for ATP SPECT. These were 75%, 49% and 60% for treadmill exercise test in the patient group including both angina and myocardial infarction. For detection of diseased vessels, the diagnostic accuracy for left anterior descending artery and right coronary artery lesions was almost equal for ATP and exercise SPECT study, but ATP SPECT study was more sensitive than exercise SPECT study in detection of left circumflex artery lesions. ATP as well as exercise SPECT studies occasionally gave false positive results in patients with single-vessel disease. ATP as well as exercise SPECT studies underestimated the severity of multi-vessel disease. In general, the results of ATP SPECT imaging were highly concordant with the results of exercise SPECT imaging. ATP stress thallium SPECT imaging provided a safe and highly accurate diagnostic tool for detection of CAD. (author)

  8. Mnemonic activation by SPECT

    International Nuclear Information System (INIS)

    Migneco, O.; Darcourt, J.; Benoit, M; Malandain, G.; Thirion, J.P.; Robert, Ph.; Vidal, R.; Desvignes, Ph.; Benoliel, J.; Ayache, N.; Bussiere, F.

    1997-01-01

    Data of literature show that SPECT is able to detect cerebral activations induced by sensory-motor stimuli. The facts are not clearly established in what concerns the cognitive activations the amplitude of which is lower. We have studied an activation paradigm such as the Grober and Bruschke test which implies the long term explicit memory. It comprises a visual presentation of words followed by their indexed recall. By using a two-day protocol, 2 SPECTs were achieved in 4 healthy right-handed voluntaries as follows: one of activation (A) and one of control (B). The fifth subject benefited by a SPECT B and of an MRI. The injection for the examination A has been done during the indexed recall stage and for the examination B at the moment when the patient repeated several times the same 3 words. The SPECT data were collected 1 hour after the injection of 370 MBq of ECD making use of a 3-head camera equipped with UHR fan collimators and ending by a LMH on the reconstructed images of 8 mm. The MRI has been achieved by means of a Signa 1.5 Tesla magnet. The SPECT A and B of the subjects 1 to 4 were matched elastically to that of the subject 5 and that of the subject 5 was rigidly matched on its MRI. In this way the individual activation cards of the 4 subjects could be averaged and superimposed on the MRI of the 5. subject. One observes an internal temporal activation (maximal activation of left tonsil, +25% and right uncus, +23%) and a right cingulum activation (maximal activation, +25%), in agreement with the neuro-physiological data. The elastic matching makes possible the inter-subject averaging, what increases the signal-to-noise ratio of activation. The inter-modality rigid matching facilitates the anatomical localisation of the activation site. With these adapted tools, the cognitive activation is thus possible by SPECT and opens perspectives for early diagnosis of neurological troubles, namely of Alzheimer's disease

  9. SPECT quantification of regional radionuclide distributions

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.

    1986-01-01

    SPECT quantification of regional radionuclide activities within the human body is affected by several physical and instrumental factors including attenuation of photons within the patient, Compton scattered events, the system's finite spatial resolution and object size, finite number of detected events, partial volume effects, the radiopharmaceutical biokinetics, and patient and/or organ motion. Furthermore, other instrumentation factors such as calibration of the center-of-rotation, sampling, and detector nonuniformities will affect the SPECT measurement process. These factors are described, together with examples of compensation methods that are currently available for improving SPECT quantification. SPECT offers the potential to improve in vivo estimates of absorbed dose, provided the acquisition, reconstruction, and compensation procedures are adequately implemented and utilized. 53 references, 2 figures

  10. Radionuclide cisternography: SPECT and 3D-rendering. Radionuklidzisternographie: SPECT- und 3D-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H; Huber, G; Piepgras, U [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Abt. fuer Neuroradiologie; Hierholzer, J [Freie Univ. Berlin (Germany, F.R.). Strahlenklinik und Poliklinik; Cordes, M [British Columbia Univ., Vancouver, BC (Canada). Belzberg Lab. of Neuroscience

    1991-10-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of {sup 111}In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.).

  11. Design of common software for quality control of SPECT

    International Nuclear Information System (INIS)

    Li Xiaohua; Gao Ruzhen; Chen Shengzu

    1993-01-01

    The goal of this study is to design a common testing system for SPECT quality control according to NEMA standard. Using the system, the performances of different types of SPECT can be tested, so that the acceptance testing, performance comparing and routine quality control for SPECT can be normalized. The system was based on IBM PC series of microcomputer. Testing data are acquired from various types of SPECT, then transferred into IBM PC through interface and tested with an unique testing program. Two parts were included: interface and SPECT testing program. It emphatically studied the managing program of RS232 interface, designing skills and the mathematic patterns of SPECT testing program. The system which was composed of 11 subroutines can be used to measure the performances for both gamma camera and SPECT. The system was tested on OMEGA 500/MCS 560 SPECT and the results showed that it is effective, accurate and easy to use

  12. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  13. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  14. Automatic determination of brain perfusion index for measurement of cerebral blood flow using spectral analysis and {sup 99m}Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Takasawa, Masashi [Division of Strokology, Department of Internal Medicine and Therapeutics, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita City, Osaka, 565-0871 (Japan); Department of Nuclear Medicine, Osaka University Graduate School of Medicine, Osaka (Japan); Murase, Kenya; Kawamata, Minoru [Department of Allied Health Sciences, Osaka University Graduate School of Medicine, Osaka (Japan); Oku, Naohiko; Imaizumi, Masao; Osaki, Yasuhiro; Paul, Asit K. [Department of Nuclear Medicine, Osaka University Graduate School of Medicine, Osaka (Japan); Yoshikawa, Takuya; Kitagawa, Kazuo; Matsumoto, Masayasu; Hori, Masatsugu [Division of Strokology, Department of Internal Medicine and Therapeutics, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita City, Osaka, 565-0871 (Japan)

    2002-11-01

    Cerebral blood flow (CBF) can be non-invasively quantified using the brain perfusion index (BPI), determined from radionuclide angiographic data generated by technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO). We previously reported the use of a spectral analysis (SA) method using {sup 99m}Tc-HMPAO to calculate the BPI. In this report, we demonstrate an automatic method for determining the optimal BPI value and compare the optimal BPI values with the absolute CBF values measured using H{sub 2}{sup 15}O positron emission tomography (PET). Bilateral cerebral hemispheres of 11 patients with various brain diseases were examined using {sup 99m}Tc-HMPAO. In the automatic SA procedure, the radioactivity curve for the aortic arch (C{sub a}) was shifted by 0-10 s. The radioactivity curve for the brain (C{sub b}) was estimated using the shifted C{sub a}, and the error value between the actually measured and the estimated C{sub b} (Err) was calculated. When the Err was at a minimum, the BPI value was defined as optimal BPI. The difference in BPI from the optimal BPI was calculated as vertical stroke BPI - optimal BPI vertical stroke / optimal BPI x 100 (%). In all participants, an H{sub 2}{sup 15}O PET examination was also performed, and the BPI values were compared with the absolute CBF values measured using H{sub 2}{sup 15}O PET (mCBF{sup PET}). The difference between BPI and the optimal BPI increased significantly from 4.87%{+-}1.69% to 18.38%{+-}3.93% (mean{+-}SD) when the Err value increased. The optimal BPI value (y) was well correlated with the mCBF{sup PET} value (x) (y=0.21x-0.0075, r=0.800). Our results suggest that this automatic SA method provides an accurate estimate of BPI that can be used for the quantification of CBF using {sup 99m}Tc-HMPAO SA. (orig.)

  15. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    Science.gov (United States)

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  16. Inter-observer variation of diagnosis of Alzheimer's disease by SPECT

    International Nuclear Information System (INIS)

    Oshima, Motoo; Machida, Kikuo; Koizumi, Kiyoshi

    2001-01-01

    SPECT shows characteristic distribution in Alzheimer's disease. The purpose of this study is to define inter-observer variations in the diagnosis of Alzheimer's disease. Fifty-seven patients, included 19 Alzheimer's disease were collected from four institutions. Five-graded score was used to interprete SPECT in 18 regions. Ten nuclear medicine physicians interpreted SPECT referred with MMSE and clinical information. Among 57 cases 19 Alzheimer's disease were selected in this study. Statistics were performed between SPECT score and MMSE score. In conclusion, inter-observer variation is present in SPECT interpretation. There was a good correlation SPECT and MMSE with proper brain SPECT physicians. They are superior to in the interpretation not only resident, but other specialists. Education in the interpretation of brain SPECT looks important. (author)

  17. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  18. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    International Nuclear Information System (INIS)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro

    2002-01-01

    The purpose of this study was to evaluate the usefulness of 99m Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  19. Evaluation of usefulness of bone SPECT for lumbar spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Osamu; Hashimoto, Manabu; Tomura, Noriaki; Watarai, Jiro [Akita Univ. (Japan). School of Medicine

    2002-07-01

    The purpose of this study was to evaluate the usefulness of {sup 99m}Tc-MDP SPECT (bone SPECT) for lumbar spondylolysis. We analyzed 11 cases with 17 lesions. All cases were compared using plain radiography, computed tomography (CT), planar bone scintigraphy (PBS), and bone SPECT. Four lesions that showed a wide defect on CT were negative on bone SPECT and may have been chronic lesions. Thirteen lesions that were positive on bone SPECT were narrow or showed no defect on CT and may have been early lesions. Two cases showed no defect on CT but were positive on bone SPECT, and one of them progressed to bilateral spondylolysis after one year. This may have been a very early lesion. Thus bone SPECT is useful for the diagnosis of lumbar spondylolysis, especially in its early stage. (author)

  20. SPECT assay of radiolabeled monoclonal antibodies

    International Nuclear Information System (INIS)

    Jaszczak, R.J.

    1992-02-01

    The long-term goal of this research project is to develop methods to improve the utility of single photon emission computed tomography (SPECI) to quantify the biodistribution of monoclonal antibodies (MoAbs) labeled with clinically relevant radionuclides ( 123 I, 131 I, and 111 In) and with another radionuclide, 211 At, recently used in therapy. We describe here our progress in developing quantitative SPECT methodology for 111 In and 123 I. We have focused our recent research thrusts on the following aspects of SPECT: (1) The development of improved SPECT hardware, such as improved acquisition geometries. (2) The development of better reconstruction methods that provide accurate compensation for the physical factors that affect SPECT quantification. (3) The application of carefully designed simulations and experiments to validate our hardware and software approaches

  1. Acute rCBF changes in depressed patients receiving repetitive transcranial magnetic stimulation (rTMS)

    International Nuclear Information System (INIS)

    Haindl, W.; Loo, C.; Mitchell, P.; Sachdev, P.; Zheng, X.; Som, S.; Walker, B.

    1999-01-01

    Full text: Electroconvulsant therapy (ECT) is very effective in treatment resistant severe depression with response rates of 70-90%. However, ECT has major limitations including the need for anaesthesia, memory difficulties and public apprehension about its use. Transcranial magnetic stimulation (rTMS) has been used as a diagnostic technique in neurology with recent reports of potential benefit in depressed patients. In this study, 5 patients (3 females, 2 males aged 36-66 years, mean 48.6 years) with major depression underwent SPET brain scanning using a Picker 3000 triple-headed camera. Each patient had a baseline rCBF scan with 500 MBq of 99 Tc m HMPAO injected intravenously during sham rTMS. On the following day, each patient received another 500 MBq of 99 Tc m HMPAo during rTMS to the left dorsolateral prefrontal cortex using a Magstim Super Rapid magnetic stimulator with a 70-mm figure eight coil. The stimulator parameters were 15 Hz, 90% of resting motor threshold, 1 s on 3 s off for 30 trains prior to injection and 15-30 trains following injection. Each patient continued to receive their usual medication during this period. The reconstructed SPET data sets were normalized to the global mean, registered to the Talairach template and analysed using statistical parametric mapping (SPM). Compared with the baseline group, the rTMS group showed a significant perfusion increase in the pre-frontal cortices, especially on the left, and also in the anterior left temporal lobe (P < 0.05). Frontal lobe perfusion reduction is a common finding in depression. This study demonstrates the ability of rTMS to acutely increase frontal lobe perfusion, and therefore a possible mechanism for its therapeutic use as an adjunct to pharmacological therapy or as an alternative to ECT in depression

  2. Uptake of SPECT radiopharmaceuticals in neocortical brain cultures

    Energy Technology Data Exchange (ETDEWEB)

    Jong, B.M. de; Royen, E.A. van

    1989-01-01

    The uptake, retention and uptake antagonism of /sup 201/Tl-DDC, /sup 201/Tl-Cl, /sup 123/I-IMP, /sup 99m/Tc-HMPAO and /sup 99m/Tc-O4/sup -/ were compared in rat neocortex cultures. /sup 201/Tl-DDC and /sup 123/I-IP revealed the highest uptake of radioactivity in the cultures. /sup 99m/Tc-HMPAO and /sup 123/I-IMP showed the highest retention of radioactivity within the tissue in washout experiments. Blocking of bioelectric activity by tetrodotoxin did not significantly affect the uptake of the radiopharmaceuticals (RPHA). Inhibition of Na K ATPase by ouabain inhibited the uptake of /sup 201/Tl-Cl (77%) and /sup 201/Tl-DDC (27%). Imipramine showed a significantly stronger inhibitory effect on /sup 123/I-IMP uptake in comparison with the effect on other RPHA. /sup 99m/Tc-O4/sup -/ was not concentrated within the cultured tissue. Under the in vitro conditions used in this study, the various RPHA were characterised by distinct differences in their interaction with cortical brain tissue.

  3. Brain imaging during seizure: ictal brain SPECT

    International Nuclear Information System (INIS)

    Kottamasu, Sambasiva Rao

    1997-01-01

    The role of single photon computed tomography (SPECT) in presurgical localization of medically intractable complex partial epilepsy (CPE) in children is reviewed. 99m Technetium neurolite, a newer lipophylic agent with a high first pass brain extraction and little or no redistribution is injected during a seizure, while the child is monitored with a video recording and continuous EEG and SPECT imaging is performed in the next 1-3 hours with the images representing regional cerebral profusion at the time of injection. On SPECT studies performed with radiopharmaceutical injected during a seizure, ictal focus is generally hypervascular. Other findings on ictal brain SPECT include hypoperfusion of adjacent cerebral cortex and white matter, hyperperfusion of contralateral motor cortex, hyperperfusion of ipsilateral basal ganglia and thalamus, brain stem and contralateral cerebellum. Ictal brain SPECT is non-invasive, cost effective and highly sensitive for localization of epileptic focus in patients with intractable CPE. (author)

  4. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  5. Clinical usefulness of normal data bases comparisons for the SPECT diagnosis of Alzheimer's disease

    International Nuclear Information System (INIS)

    Darcourt, J.; Koulibaly, P.M.; Migneco, O.; Dygai, I.; Robert, P.H.; Nobili, F.; Ebmeir, K.

    2002-01-01

    Aim. The possible added value of voxel by voxel comparisons to normal data bases has not been evaluated for the diagnosis of Alzheimer's disease (AD). We conducted a prospective comparison of the diagnostic performances of 2 software packages: Statistical Parametric Mapping (SPM) (Friston et al.) and NeuroGam (NGam) (Segami Corporation). Materials and methods. A total of 152 subjects (age ≥ 50 years) were included: 93 AD, 28 depressed patients and 31 normal controls (NC). They were studied in 4 centers as part of a European project 'SPECT in dementia' BMH4-98-3130. NC were used to build the normal data bases and the total population was submitted to the readers for the diagnosis of AD. AD final diagnosis was based on NINCDS/ADRDA criteria for probable AD and DSM-IV criteria for dementia of AD type. SPECT scans were obtained in each center with dedicated cameras 30 to 90 min after i.v. injection of 250 to 925 MBq of 99mTc-HMPAO. All data were reconstructed on the same workstation by filtered backprojection with attenuation correction. The 4.7 mm thick cuts (CUTS) were displayed in the transverse, sagittal and coronal planes with the same color scale. They also were submitted to the 2 packages tested. For SPM, we used SPM'96 for Windows'95. For each individual scan we computed the corresponding z-map by comparison to the NC data base. We used p<0.01 to threshold the t-maps and a p corrected value <0.01 on intensity for cluster selection. For NGam, the same NC were used to build the normal data base. Each individual scan was then compared to this base and the results consisted in a 3D parametric image of voxel by voxel standard deviations form the normal mean value. 4 expert readers (more than 3 years experience; more than 5 SPECT per week) were asked to class the scans as AD or not with a 4 degree of confidence. They reviewed the CUTS alone, CUTS+SPM and CUTS+NGam. ROC analysis was performed and the areas under curves (AUC) statistically compared. Results. Average

  6. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile ( 99m Tc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging

  7. Labeling of autologous monocytes with 99mTc-HMPAO at very high specific radioactivity

    International Nuclear Information System (INIS)

    Hemert, Formijn J. van; Thurlings, Rogier; Dohmen, Serge E.; Voermans, Carlijn; Tak, Paul P.; Eck-Smit, Berthe L.F. van; Bennink, Roelof J.

    2007-01-01

    Rheumatoid arthritis of joints involves the accumulation of monocyte-derived macrophages in the affected synovial tissue. This process of cell migration can be portrayed scintigraphically in order to monitor noninvasive effects of therapy on the progress of the disease. Scintigraphic detection of inflammation by means of technetium 99m-hexamethylpropylene amine oxime ( 99m Tc-HMPAO)-labeled leukocytes provides a classic example. Present state-of-the-art methods in cell biology allow the isolation of cells like lymphocytes or monocytes, which are less abundant than main blood constituents but, instead, harbor particular functions like specific homing properties. To facilitate scintigraphic imaging of the cell functions involved, the relatively small population of cells must be labeled to radioactive yields as high as possible. We demonstrate that autologous monocytes isolated from 100 ml of peripheral blood can be radiolabeled to a yield of 10 (instead of 1) Bq per cell, allowing scintigraphic analysis of rheumatoid arthritis up to 20 h post injection of patients. The method is based on the instantaneous distribution of lipophilic 99m Tc-HMPAO between the hydrophobic inside of cells and the hydrophilic (aqueous) surrounding of cells, followed by decomposition of the radiopharmaceutical into compounds that are unable to cross the cellular membrane. The procedure provides a method of choice for cell-mediated scintigraphy at low availability of cells with the correct homing properties

  8. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  9. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  10. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  11. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  12. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  13. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  14. Clinical Evaluation of Brain Perfusion SPECT with Brodmann Areas Mapping in Early Diagnosis of Alzheimer's Disease.

    Science.gov (United States)

    Valotassiou, Varvara; Papatriantafyllou, John; Sifakis, Nikolaos; Tzavara, Chara; Tsougos, Ioannis; Psimadas, Dimitrios; Fezoulidis, Ioannis; Kapsalaki, Eftychia; Hadjigeorgiou, George; Georgoulias, Panagiotis

    2015-01-01

    Early diagnosis of Alzheimer's disease (AD) based on clinical criteria alone may be problematic, while current and future treatments should be administered earlier in order to be more effective. Thus, various disease biomarkers could be used for early detection of AD. We evaluated brain perfusion with 99mTc-HMPAO single photon emission computed tomography (SPECT) and Brodmann areas (BAs) mapping in mild AD using an automated software (NeuroGam) for the semi-quantitative evaluation of perfusion in BAs and the comparison with the software's normal database. We studied 34 consecutive patients with mild AD: 9 men, 25 women, mean age 70.9 ± 8.1 years, mean Mini-Mental State Examination 22.6 ± 2.5. BAs 25L, 25R, 38L, 38R, 28L, 28R, 36L, and 36R had the lower mean perfusion values, while BAs 31L, 31R, 19R, 18L, 18R, 17L, and 17R had the higher mean values. Compared with healthy subjects of the same age, perfusion values in BAs 25L, 25R, 28R, 28L, 36L, and 36R had the greatest deviations from the healthy sample, while the lowest deviations were found in BAs 32L, 32R, 19R, 24L, 17L, 17R, 18L, and 18R. A percentage of ≥94% of patients had perfusion values more than -2SDs below the mean of healthy subjects in BAs 38R, 38L, 36L, 36R, 23L, 23R, 22L, 44L, 28L, 28R, 25L, and 25R. The corresponding proportion was less than 38% for BAs 11L, 19R, 32L, 32R, 18L, 18R, 24L, and 17R. In conclusion, brain SPECT studies with automated perfusion mapping could be useful as an ancillary tool in daily practice, revealing perfusion impairments in early AD.

  15. Clinical applications of SPECT/CT: advantages and limitations

    International Nuclear Information System (INIS)

    Rigo, P.

    2006-01-01

    The application of hybrid SPECT cameras in Nuclear Medicine follows the revolutionary introduction of PET/CT. This review focuses on the advantages and limitations of SPECT/CT in its various clinical indications. It appears that SPECT/CT will be a clear factor of progress for Nuclear Medicine. (author)

  16. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  17. Comparative analysis of {sup 99m}Tc-MDP three-phase bone scan with SPECT/CT and {sup 99m}Tc-HMPAO-labeled WBC SPECT/CT in the differential diagnosis of clinically suspicious post-traumatic osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Chan Woo; Lee, Soo Jin; Kim, Ji Young; Hwang, Kyu Tae; Choi, Yun Young [Hanyang University Medical CenterSeoul (Korea, Republic of)

    2017-03-15

    To identify differences between three-phase bone scan and SPECT/CT (TBS) and WBC SPECT/CT (WS) and compare diagnostic accuracies of each modality in patients with suspicious post-traumatic osteomyelitis (OM). Twenty-one patients with suspicious post-traumatic OM were enrolled. All patients performed TBS and WS within 1 week. Foci of MDP and WBC accumulation were divided into three categories: bone (OM), soft tissue (soft tissue inflammation; STI), negative for inflammation (NI). Confirmative diagnosis was made upon operative pathology or long-term clinical follow-up. Of 21 patients, four OM, eight STI, nine NI were finally diagnosed. TBS diagnosis was correct in three of four positive cases and nine of 17 negative cases. Sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV) of TBS were 75 %, 52.9 %, 57.1 %, 27.3 %, 90 %. WS diagnosis was correct in two of four positive cases and 17 of 17 negative cases. Sensitivity, specificity, accuracy, PPV, NPV were 50 %, 100 %, 81.0 %, 100 %, 89.5 %. Twelve of 21 cases showed agreement between TBS and WS. TBS misdiagnosed nine cases (six STI and two NI as eight OM; one OM as one STI), while WS misdiagnosed four cases (two OM as two STI; two STI as two NI). Combining results from TBS and WS led to better diagnostic accuracy (91.7 %) than either TBS or WS alone. TBS and WS showed moderate agreement in assessment of clinically suspected post-traumatic OM. WS better evaluated inflammation than TBS. WS tended to underestimate inflammation whereas TBS tended to overestimate inflammation. Combining TBS and WS enhanced diagnostic accuracy.

  18. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  19. Clinical significance of abdominal scintigraphy using {sup 99m}Tc-HMPAO-labelled leucocytes in patients with seronegative spondyloarthropathies

    Energy Technology Data Exchange (ETDEWEB)

    Alonso Farto, J.C.; Almoguera Arias, I.; Ortega Valle, A.; Perez Vazquez, J.M. [Department of Nuclear Medicine, Univ. Complutense, Madrid (Spain); Lopez Longo, F.J.; Gonzalez Fernandez, C.M.; Monteagudo Saez, I.; Bascones, M.; Carreno Perez, L. [Department of Rheumatology, ' ' Hospital Universitario Gregorio Maranon' ' , Universidad Complutense, Madrid (Spain)

    2000-12-01

    Abdominal scintigraphy shows silent gut inflammation in patients with spondyloarthropathies (Sp) without clinical evidence of gut inflammation. Abdominal scintigraphy images are different than those obtained in patients with ulcerative colitis or Crohn's disease and are not related to the anti-inflammatory drugs administered. The aim of this study was to examine the clinical associations of findings on abdominal scintigraphy in patients with Sp. A total of 204 Sp patients (European Spondylarthropathy Study Group 1991 criteria) and 54 non-Sp controls receiving non-steroidal anti-inflammatory drugs were studied. Abdominal scintigraphy images were obtained at 30 and 120 min after injection of technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO)-labelled leucocytes. {sup 99m}Tc-HMPAO-labelled leucocyte scans were positive in 104 Sp patients (50.9%) and in six non-Sp controls (2.9%) (P<0.001; OR=8.32; 95% CI=3.23-22.67). Silent gut inflammation was not associated with any of the following: age of onset, duration of evolution, sex, family history of Sp or psoriasis, articular manifestations, extra-articular manifestations, radiological findings or HLA-B27 positivity. Positive abdominal scintigraphy was associated with active disease (P<0.0001; OR=52.7; 95% CI=19-145.6) and an increase in the C-reactive protein (P<0.005; OR=3.4; 95% CI=1.5-7.4). It is concluded that (a) abdominal scintigraphy using {sup 99m}Tc-HMPAO-labelled leucocytes is of value in detecting the silent gut inflammation in Sp patients, and (b) silent gut inflammation is related to the clinical activity, but is not associated with any particular type of illness or with HLA-B27. (orig.)

  20. Imaging the neurobiological substrate of atypical depression by SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Pagani, Marco [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Karolinska University Hospital, Department of Nuclear Medicine, Stockholm (Sweden); Salmaso, Dario [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Nardo, Davide [University of Rome La Sapienza, Department of Psychology, Rome (Italy); Jonsson, Cathrine; Larsson, Stig A. [Karolinska University Hospital, Department of Nuclear Medicine, Stockholm (Sweden); Jacobsson, Hans [Karolinska University Hospital, Department of Radiology, Stockholm (Sweden); Gardner, Ann [Karolinska University Hospital Huddinge, Karolinska Institutet, Department of Clinical Neuroscience, Section of Psychiatry, Stockholm (Sweden)

    2007-01-15

    Neurobiological abnormalities underlying atypical depression have previously been suggested. The purpose of this study was to explore differences at functional brain imaging between depressed patients with and without atypical features and healthy controls. Twenty-three out-patients with chronic depressive disorder recruited from a service for patients with audiological symptoms were investigated. Eleven fulfilled the DSM-IV criteria for atypical depression (mood reactivity and at least two of the following: weight gain, hypersomnia, leaden paralysis and interpersonal rejection sensitivity). Twenty-three healthy subjects served as controls. Voxel-based analysis was applied to explore differences in {sup 99m}Tc-HMPAO uptake between groups. Patients in the atypical group had a higher prevalence of bilateral hearing impairment and higher depression and somatic distress ratings at the time of SPECT. Significantly higher tracer uptake was found bilaterally in the atypical group as compared with the non-atypicals in the sensorimotor (Brodmann areas, BA1-3) and premotor cortex in the superior frontal gyri (BA6), in the middle frontal cortex (BA8), in the parietal associative cortex (BA5, BA7) and in the inferior parietal lobule (BA40). Significantly lower tracer distribution was found in the right hemisphere in the non-atypicals compared with the controls in BA6, BA8, BA44, BA45 and BA46 in the frontal cortex, in the orbito-frontal cortex (BA11, BA47), in the postcentral parietal cortex (BA2) and in the multimodal association parietal cortex (BA40). The differences found between atypical and non-atypical depressed patients suggest different neurobiological substrates in these patient groups. The putative links with the clinical features of atypical depression are discussed. These findings encourage the use of functional neuroimaging in psychiatric disorders. (orig.)

  1. Imaging the neurobiological substrate of atypical depression by SPECT

    International Nuclear Information System (INIS)

    Pagani, Marco; Salmaso, Dario; Nardo, Davide; Jonsson, Cathrine; Larsson, Stig A.; Jacobsson, Hans; Gardner, Ann

    2007-01-01

    Neurobiological abnormalities underlying atypical depression have previously been suggested. The purpose of this study was to explore differences at functional brain imaging between depressed patients with and without atypical features and healthy controls. Twenty-three out-patients with chronic depressive disorder recruited from a service for patients with audiological symptoms were investigated. Eleven fulfilled the DSM-IV criteria for atypical depression (mood reactivity and at least two of the following: weight gain, hypersomnia, leaden paralysis and interpersonal rejection sensitivity). Twenty-three healthy subjects served as controls. Voxel-based analysis was applied to explore differences in 99m Tc-HMPAO uptake between groups. Patients in the atypical group had a higher prevalence of bilateral hearing impairment and higher depression and somatic distress ratings at the time of SPECT. Significantly higher tracer uptake was found bilaterally in the atypical group as compared with the non-atypicals in the sensorimotor (Brodmann areas, BA1-3) and premotor cortex in the superior frontal gyri (BA6), in the middle frontal cortex (BA8), in the parietal associative cortex (BA5, BA7) and in the inferior parietal lobule (BA40). Significantly lower tracer distribution was found in the right hemisphere in the non-atypicals compared with the controls in BA6, BA8, BA44, BA45 and BA46 in the frontal cortex, in the orbito-frontal cortex (BA11, BA47), in the postcentral parietal cortex (BA2) and in the multimodal association parietal cortex (BA40). The differences found between atypical and non-atypical depressed patients suggest different neurobiological substrates in these patient groups. The putative links with the clinical features of atypical depression are discussed. These findings encourage the use of functional neuroimaging in psychiatric disorders. (orig.)

  2. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    Science.gov (United States)

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR

  3. SPECT imaging with resolution recovery

    International Nuclear Information System (INIS)

    Bronnikov, A. V.

    2011-01-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  4. Rapid gated Thallium-201 perfusion SPECT - clinically feasible?

    International Nuclear Information System (INIS)

    Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.; Wilkinson, D.; Abatti, D.

    1998-01-01

    Full text: Standard dose energy window optimised Thallium-201 (Tl-201) SPECT has about half the counts of a standard dose from Technetium-99m Sestamibi (Tc99m-Mibi) gated perfusion SPECT. This study investigates the clinical feasibility of rapid energy window optimised Tl-201 gated perfusion SPECT (gated-TI) and compares quantitative left ventricular ejection fraction (LVEF) and visually assessed image quality for wall motion and thickening to analogous values obtained from Tc99m-Mibi gated perfusion SPECT (gated - mibi). Methods: We studied 60 patients with a rest gated Tl-201 SPECT (100 MBq, 77KeV peak, 34% window, 20 sec/projection) followed by a post stress gated Sestamibi SPECT (1GBq, 140KeV, 20% window, 20 sec/projection) separate dual isotope protocol. LVEF quantitation was performed using commercially available software (SPECTEF, General Electric). Visual grading of image quality for wall thickening and motion was performed using a three-point scale (excellent, good and poor). Results: LVEF for gated Tl-201 SPECT was 59.6 ± 12.0% (Mean ± SD). LVEF for gated Sestamibi SPECT was 60.4 ±11.4% (Mean ± SD). These were not significantly different (P=0.27, T-Test). There was good correlation (r=0.9) between gated-TI and gated-mibi LVEF values. The quality of gated-Tl images was ranked as excellent, good and poor in 12, 50 and 38% of the patients respectively. Image quality was better in gated-mibi SPECT, with ratings of 12, 62 and 26% respectively. Conclusion: Rapid gated Thallium-201 acquisition with energy window optimisation can be effectively performed on majority of patients and offers the opportunity to assess not only myocardial perfusion and function, as with Technetium based agents, but also viability using a single day one isotope protocol

  5. Role of SPECT imaging in symptomatic posterior element lumbar stress injuries

    Directory of Open Access Journals (Sweden)

    Debnath U

    2005-01-01

    Full Text Available Background : Diagnosis of stress injuries of spine is very difficult with conventional radiography. Methods : In a observational study, 132 subjects were recruited (between 8 and 38 years of age, who had lumbar spondylolysis or posterior element stress injuries. All these patients underwent clinical examination followed by plain X-rays, planar bone scintigraphy and SPECT (single photon emission computerised tomography. SPECT scans can identify the posterior element lumbar stress injuries earlier than other imaging modalities. As the lesions evolve and the completed spondylolysis becomes chronic, the SPECT scans tend to revert to normal even though healing of the defect has not occurred. The aim of the study was to determine the time lag after which SPECT imaging tends to be negative. We divided the patients into two groups, one SPECT positive group and the other SPECT negative group. Pre treatment background variables such as age, gender, back pain in extension or flexion, sporting activities, time of onset of symptoms, Oswestry Disability Index (ODI were used in a univariate logistic regression model to find the strong predictors of positive SPECT imaging results. Determinants of positivity versus negativity of SPECT were identified by discriminant analysis using multivariate logistic regression. Results : Seventy nine patients had positive SPECT scans whereas 53 patients had negative SPECT scans. Bilateral increased uptake was more common than unilateral uptake. Increased uptake at the L5 lumbar spine was more common (70% in SPECT positive group. Low back pain in extension was significantly more common in SPECT positive subjects. Active sporting individuals had higher probability of having a positive SPECT scan. The mean time lag from the onset of low back pain to SPECT imaging was 7 months in SPECT positive group and 25 months in the SPECT negative group. Multivariate analysis predicted that there is a significant difference in positivity of

  6. Evaluation of the diagnostic performance of SPECT coupled to tomodensitometry (SPECT-CT) in the daily practice of bone scintigraphy at the Nuclear Medical station of Nancy

    International Nuclear Information System (INIS)

    Netter, F.; Journo, A.; Mayer, J.C.; Grandpierre, S.; Daragon, N.; Karcher, G.; Olivier, P.; Scigliano, S.

    2008-01-01

    Objective: The purpose of our study was to evaluate the diagnostic performance of SPECT coupled to computed axial tomography (SPECT- CT) in our daily practice of bone scintigraphy. Subjects and methods: SPECT- CT obtained as a complement to the planar bone scintigraphy in 39 patients were studied. Each type of image was retrospectively read by two different observers: a nuclear medicine physician who was unaware of SPECT- CT results analysed planar bone scintigraphy, a second one who was unaware of planar bone scintigraphy results analysed SPECT- CT images. In this population of patients, 17 patients were addressed in an oncologic setting. The 22 other patients were addressed for pain of indeterminate origin without neoplastic context. Results: In 13% of the cases, SPECT- CT specified the precise location of increased uptake foci seen on planar bone scintigraphy. In 38% of cases, SPECT- CT confirmed a diagnosis suspected by the planar bone scintigraphy. In 10% of cases, SPECT- CT established a diagnosis that was uncertain with planar bone scintigraphy. In 26% of cases, SPECT- CT brought no additional information. Finally in 3% of cases, SPECT- CT proved to be more sensitive than planar images. Conclusion: Our study demonstrates the utility of SPECT- CT in the daily practice of bone scintigraphy, this complementary imaging study benefited to 74% of our patients. (authors)

  7. Serial cerebral hemodynamic change after extracranial-intracranial (EC-IC) bypass surgery: evaluated by acetazolamide stress brain perfusion SPECT(acz-SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Il Ki; Kim, Jae Seung; Ahn, Jae Sung; Im, Ki Chun; Kim, Euy Nyong; Mun, Dae Hyeog [Asan Medical Center, Seoul (Korea, Republic of)

    2005-07-01

    We evaluated serial cerebral hemodynamic changes after EC-IC bypass surgery in symptomatic pts with atherosclerotic occlusion of internal carotid (lCA) or mid-cerebral artery (MCA) using Acz-SPECT. 25 symptomatic pts (M/F 19/6, 53{+-}10 y) with ICA and MCA occlusion (16 uni - and 9 bilateral) prospectively underwent Acz-SPECT using Tc-99m ECD before and 1 week after EC-IC bypass surgery. Of these, 16 underwent additional f/u Acz-SPECT 5 mo later. Cerebral perfusion and perfusion reserve of MCA territory were evaluated visually and SPECT findings were classified into 4 groups: N/N; R/N; N/R; and R/R (perfusion/perfusion reserve: N = normal, R = reduced). For semiquantitative analysis, all SPECT images were normalized to MNI template and mean counts of MCA territory and cerebellum were obtained by AAL. Cerebral perfusion index (PI =C{sub region}/C{sub cere}) and perfusion reserve index (RI = (PI{sub Acz} - PI{sub basal}) /Pl{sub basal}) were calculated. Preop SPECT findings of ipsilateral MCA in 25 pts were R/N (4%), N/R (12%), and R/R (84% ). Early postop SPECT showed improvement of perfusion (26%) and/or reserve (68%) in ipsilateral MCA. Of 16 pts with 5mo f/u SPECT, 6 (38%) showed further improvement of perfusion or reserve. However, 4 (25%) showed aggravation of perfusion and one of these underwent revision surgery. Preop PI (1.1{+-}0.1) and RI (0.11{+-}0.07) of ipsilateral MCA were significantly lower than those of contralateral hemispheres (p<0.05). After surgery, PIs of bilateral MCA did not change at early postop period but improved in ipsilateral MCA at 5mo. Rls of ipsilateral MCA increased significantly (68%) at early postop period (P<0.001) and then did not changed. Cerebral perfusion and perfusion reserve changed with different manner during 5 mo after bypass surgery and perfusion reserve changed more dramatically than perfusion. Acz-SPECT is a feasible method for evaluating cerebral hemodynamic change after EC-IC bypass surgery.

  8. Noninvasive evaluation of ischemic stroke with SPECT

    International Nuclear Information System (INIS)

    Gomez, C.R.; Malik, M.M.; Gomez, S.M.; Wingkun, E.C.

    1988-01-01

    Technetium Tc 99m DTPA single photon emission computerized tomography (SPECT) brain scans of 20 patients with acute ischemic stroke were reviewed retrospectively and compared with clinical and radiologic (CT) data. Fourteen of the patients had abnormal SPECT studies. The abnormal findings were demonstrated by static views in eight patients, by the flow study in one patient, and by both sets of images in the other five patients. All abnormalities correlated with the clinical syndrome of presentation, and only two of the patients had no corresponding lesions on CT. Of the six patients with normal SPECT scans, two had abnormal CT studies, and in the other four, no lesions were shown at all. The ability of /sup 99m/Tc DTPA SPECT to display cerebral infarctions appears to be, at best, comparable to that of CT. SPECT also provides qualitative information regarding flow dynamics in the affected hemisphere of some patients (6/20 in our review). This, we believe, represents the objective demonstration of the preexisting insufficient collateral flow in the hemisphere at risk for ischemic stroke

  9. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  10. Wirksamkeit und Sicherheit von Fumarsäureestern in Kombination mit Phototherapie bei Patienten mit moderater bis schwerer Plaque-Psoriasis (FAST).

    Science.gov (United States)

    Weisenseel, Peter; Reich, Kristian; Griemberg, Wiebke; Merten, Katharina; Gröschel, Christine; Gomez, Natalie Nunez; Taipale, Kirsi; Bräu, Beate; Zschocke, Ina

    2017-02-01

    Die Behandlung von Psoriasis-Patienten mit einer Kombination aus Fumarsäureestern (FSE, Fumaderm ® ) und Phototherapie (UV) ist verbreitet, wurde aber im Rahmen von Studien wenig untersucht. Bisher liegen lediglich Daten aus einer kleinen Pilotstudie vor. Intention dieser Studie war, eine FSE/UV-Kombinationsbehandlung an einem größeren Patientenkollektiv mit mittelschwerer bis schwerer Psoriasis zu untersuchen. In dieser prospektiven, multizentrischen, nichtinterventionellen Studie wurden Daten von Patienten mit FSE/UV-Kombinationstherapie hinsichtlich der Wirksamkeit (PGA' PASI, DLQI, EQ-5D), Sicherheit und Dosierung über einen Zeitraum von zwölf Monaten erfasst und mit Daten einer retrospektiven Studie mit FSE-Monotherapie verglichen. Es wurden Daten von 363 Patienten ausgewertet. Unter der Kombinationstherapie verbesserten sich alle Wirksamkeitsparameter deutlich. Im Vergleich zur Monotherapie mit FSE konnte durch die Kombination mit UV ein schnellerer Wirkeintritt erzielt werden, wobei nach zwölf Monaten kein Unterschied in der Wirksamkeit bestand. Die Dauer und Art der Phototherapie zeigte keinen Einfluss auf die Wirksamkeitsparameter. Allgemein wurde die Kombinationstherapie gut vertragen. Unerwünschte Ereignisse wurden bei 7 % der Patienten berichtet. Die FSE/UV Kombinationstherapie zeigt eine gute Wirksamkeit und Verträglichkeit und kann zu einem schnelleren Wirkeintritt führen. Eine Kombinationstherapie erscheint vor allem in den ersten drei Monaten der FSE Behandlung sinnvoll. © 2017 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  11. MACH MIT: Deutsches Wochenende am Karlsfluss (MACH MIT: a German Week-End on the Charles River).

    Science.gov (United States)

    Reizes, Sonia; Kramsch, Claire J.

    1980-01-01

    Describes a joint high school/college pilot program planned by Massachusetts foreign language teachers and hosted by M.I.T. The success of the program dubbed "MACH MIT Total Immersion German Weekend" is attributed to the concept of active involvement, which was implemented through games, seminars, shows, cooking and other activities.…

  12. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    International Nuclear Information System (INIS)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul

    2000-01-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.=20

  13. Ictal cerebral perfusion patterns in partial epilepsy: SPECT subtraction

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyang Woon; Hong, Seung Bong; Tae, Woo Suk; Kim, Sang Eun; Seo, Dae Won; Jeong, Seung Cheol; Yi, Ji Young; Hong, Seung Chyul [Sungkyunkwan Univ. School of Medicine, Seoul (Korea, Republic of)

    2000-06-01

    To investigate the various ictal perfusion patterns and find the relationships between clinical factors and different perfusion patterns. Interictal and ictal SPECT and SPECT subtraction were performed in 61 patients with partial epilepsy. Both positive images showing ictal hyperperfusion and negative images revealing ictal hypoperfusion were obtained by SPECT subtraction. The ictal perfusion patterns of subtracted SPECT were classified into focal hyperperfusion, hyperperfusion-plus, combined hyperperfusion-hypoperfusion, and focal hypoperfusion only. The concordance rates with epileptic focus were 91.8% in combined analysis of ictal hyperperfusion and hypoperfusion images of subtracted SPECT, 85.2% in hyperperfusion images only of subtracted SPECT, and 68.9% in conventional ictal SPECT analysis. Ictal hypoperfusion occurred less frequently in temporal lobe epilepsy (TLE) than extratemporal lobe epilepsy. Mesial temporal hyperperfusion alone was seen only in mesial TLE while lateral temporal hyperperfusion alone was observed only in neocortical TLE. Hippocampal sclerosis had much lower incidence of ictal hypoperfusion than any other pathology. Some patients showed ictal hypoperfusion at epileptic focus with ictal hyperperfusion in the neighboring brain regions where ictal discharges propagated. Hypoperfusion as well as hyperperfusion in ictal SPECT should be considered for localizing epileptic focus. Although the mechanism of ictal hypoperfusion could be an intra-ictal early exhaustion of seizure focus or a steal phenomenon by the propagation of ictal discharges to adjacent brain areas, further study is needed to elucidate it.

  14. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  15. Advances in SPECT Instrumentation (Including Small Animal Scanners). Chapter 4

    International Nuclear Information System (INIS)

    Di Domenico, G.; Zavattini, G.

    2009-01-01

    Fundamental major efforts have been devoted to the development of positron emission tomography (PET) imaging modality over the last few decades. Recently, a novel surge of interest in single photon emission computed tomography (SPECT) technology has occurred, particularly after the introduction of the hybrid SPECT-CT imaging system. This has led to a flourishing of investigations in new types of detectors and collimators, and to more accurate refinement of reconstruction algorithms. Along with SPECT-CT, new, fast gamma cameras have been developed for dedicated cardiac imaging. The existing gap between PET and SPECT in sensitivity and spatial resolution is progressively decreasing, and this trend is particularly apparent in the field of small animal imaging where the most important advances have been reported in SPECT tomographs. An outline of the basic features of SPECT technology, and of recent developments in SPECT instrumentation for both clinical applications and basic biological research on animal models is described. (author)

  16. 123I-amphetamine-SPECT in the diagnosis of neurological disorders

    International Nuclear Information System (INIS)

    Biersack, H.J.; Kreiten, K.; Hartmann, A.; Friedrich, G.; Linck, H.A.; Winkler, C.; Bonn Univ.; Rheinische Landesklinik, Bonn

    1985-01-01

    In contrast to conventional brain scintigraphy with sup(99m)Tc-pertechnetate, SPECT with 123 I-IMP enables visualization of the brain tissue itself. The relevance of this imaging technique was evaluated in 54 patients with cerebral disorders. SPECT of the brain was performed with a rotating gamma camera. In 6 of 24 epileptic patients, SPECT revealed foci consistent with EEG-findings which were, however, not detected by CCT. In 4 of 25 patients with cerebrovascular disease, hypoperfused areas were detected by SPECT despite negative results obtained with CCT. In 50% (10/20) of the patients with cerebrovascular disease, SPECT showed a greater functional extent of the lesions than CCT. In 3 patients with migraine and normal CCT, regional perfusion disturbancers were found. SPECT with 123 I-labeled amphetamines, therefore, enables diagnosis of functional perfusion disorders and metabolic disturbances that are not revealed by CCT. In addition, SPECT can be used to exactly demonstrate the functional extent of lesions detected by CCT. (orig.) [de

  17. I-123 Iofetamine SPECT scan in children with neurological disorders

    International Nuclear Information System (INIS)

    Flamini, J.R.; Konkol, R.J.; Wells, R.G.; Sty, J.R.

    1990-01-01

    I-123 Iofetamine (IMP) single photon emission computed tomography (SPECT) imaging of the brain in 42 patients (ages 14 days to 23 years) was compared with other localizing studies in children with neurological diseases. All had an EEG and at least one imaging study of the brain (computed tomography (CT) or magnetic resonance imaging (MRI), or both). Seventy-eight percent of the patients had an EEG within 24-72 hours of the IMP-SPECT scan. Thirty-five (83%) had a history of seizures, and the remainder had other neurological conditions without a history of seizures. In most cases, a normal EEG reading with normal CT or MRI result predicted a normal SPECT study. When the EEG was abnormal the majority of the IMP-SPECT scans were abnormal and localized the abnormality to the same region. A comparison with CT and MRI showed that structural abnormalities involving the cortex were usually well demonstrated with IMP-SPECT imaging. Structural lesions confined to the white matter were generally not detectable with IMP-SPECT. In a few cases, SPECT scans revealed abnormalities in deep brain areas not identified by EEG. IMP-SPECT imaging is a valuable technique for the detection and localization of abnormal cerebral metabolic activity in children with seizure disorders. A correlation with CT or MRI is essential for proper interpretation of abnormalities detected with IMP SPECT imaging

  18. Dopamine-transporter SPECT and Dopamine-D2-receptor SPECT in basal ganglia diseases

    International Nuclear Information System (INIS)

    Hesse, S.; Barthel, H.; Seese, A.; Sabri, O.

    2007-01-01

    The basal ganglia comprise a group of subcortical nuclei, which are essential for motor control. Dysfunction of these areas, especially in dopaminergic transmission, results in disordered movement and neurological diseases such as Parkinson's disease, Wilson's disease, or Huntington disease. Positron emission tomography and single photon emission computed tomography (SPECT) have enhanced the understanding of the underlying pathophysiology, but they much more contribute to the early differential diagnosis of patients suffering from Parkinsonian syndrome in routine care. The present article provides dopamine transporter and D 2 receptor SPECT findings in selected movement disorders. (orig.)

  19. Technical approach to improvement of SPECT images

    International Nuclear Information System (INIS)

    Fukukita, Hiroyoshi

    1985-01-01

    At present, a large number of SPECT systems are being widely used in Japan, hence, it is reasonable for us to know the physical and imaging characteristics of these SPECT devices, and also to recommend the optimum utility of SPECT systems. For this reason, a survey respect of characteristics of the commercialy available SPECT devices was carried out. In addition to this, various factors which have significant influence over SPECT image quality, such as, data acquisition matrix, reconstruction filter, γ-ray attenuation correction and daily quality control procedure, were also investigated. The materials used for this study are PET/SPECT phantom, Alderson liver phantom filled with Tc-99m solution, and either LFOV-E or ZLC-7500 interfaced to Scintipac 2400 minicomputer with 256 K byte of memory. Following are the results of this study. 1) The suitable data acquisition procedure was 128 x 128 matrix for linear sampling and approximately 64 views for angular sampling. 2) Reconstructed image using pre-processing filter with Wiener and Butterworth filters provided high quality image as compared with the Ramp filter. 3) Weighted backprojection method (WBP) proposed by Tanaka was superior to other methods, such as Sorenson method and Chang method in the object with non-uniform distribution of radionuclide. 4) It was found that uniformity correction of gamma camera and precise adjustment of the center of rotation are most important to maintain the images with a high quality. (author)

  20. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  1. PET and SPECT in neurology

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Ghent Univ.; Vries, Erik F.J. de; Waarde, Aren van; Otte, Andreas

    2014-01-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  2. MITS machine operations

    International Nuclear Information System (INIS)

    Flinchem, J.

    1980-01-01

    This document contains procedures which apply to operations performed on individual P-1c machines in the Machine Interface Test System (MITS) at AiResearch Manufacturing Company's Torrance, California Facility

  3. Atlas of Skeletal SPECT/CT Clinical Images

    International Nuclear Information System (INIS)

    2016-01-01

    The atlas focuses specifically on single photon emission computed tomography/computed tomography (SPECT/CT) in musculoskeletal imaging, and thus illustrates the inherent advantages of the combination of the metabolic and anatomical component in a single procedure. In addition, the atlas provides information on the usefulness of several sets of specific indications. The publication, which serves more as a training tool rather than a textbook, will help to further integrate the SPECT and CT experience in clinical practice by presenting a series of typical cases with many different patterns of SPECT/CT seen in bone scintigraphy

  4. Chilaiditi's syndrome demonstrated by SPECT/CT

    Directory of Open Access Journals (Sweden)

    Nalini S Perumal

    2009-11-01

    Full Text Available Purpose: Chilaiditi’s syndrome is a rare condition commonly diagnosed as an incidental radiological finding. The aim of this report is to show the role of SPECT-CT in this syndrome and state the functional and anatomical role of this hybrid imaging modality. Materials and Methods: A case report. Results: A 49-year-old female patient was referred for gallium-67 citrate for a possible granulomatous myositis and underwent SPECT-CT of the abdomen to assess the area of decreased gallium uptake on planar images of the liver. The combined SPECT and CT modality demonstrated findings consistent with the clinical evidence of Chilaiditi’s syndrome. The anatomical part of this hybrid modality made it easier to evaluate the area of gallium lack of uptake which was due to air in the colon. Conclusion: This case does not only show the role of SPECT-CT in this syndrome but also suggest that the use of such modality should be considered whenever available in the evaluation of patients in whom the localization of active disease becomes imperative.

  5. SPECT I-123 iodoamphetamine brain imaging

    International Nuclear Information System (INIS)

    Tikofsky, R.S.; Liebman, A.; Hellman, R.S.; Collier, B.D.; Voslar, A.M.

    1988-01-01

    SPECT/IMP studies of 100 patients with a presumptive diagnosis of dementia were performed with a rotating gamma camera 15-20 minutes after intravenous injection of 3.5 mCi of IMP. Of these studies, 43 were interpreted as normal for age; 28 demonstrated decreased but not absent activity bilaterally in posterior parietal/occipital regions (consistent with Alzheimer-type dementia); 28 showed unilateral abnormalities in regional cerebral blood flow consistent with cerebrovascular disease; and one had mixed findings. Based on SPECT/IMP results, further diagnostic testing and/or management would be altered for 72% of patients, suggesting that SPECT/IMP provides valuable data, not available on clinical examination, to guide the evaluation and management of demented patients

  6. Clinical applications of SPECT/CT in imaging the extremities

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Strobel, Klaus

    2014-01-01

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  7. Clinical applications of SPECT/CT in imaging the extremities

    Energy Technology Data Exchange (ETDEWEB)

    Huellner, Martin W. [University Hospital Zurich, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland)

    2014-05-15

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  8. SPECT for smokers brain perfusion evaluation; SPECT para avaliacao da perfusao cerebral em fumantes

    Energy Technology Data Exchange (ETDEWEB)

    Maliska, C.M.; Martins, E.F.; Barros, D.S.; Lopes, M.M.S.; Lourenco, C.; Goncalves, S.; Goncalves, M.B.; Miranda, M.M.B.G.; Neto, L.M.; Penque, E.; Antonucci, J.B. [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil)

    2002-07-01

    Cigarette smoking increases brain stroke risk, however,five to fifteen years after ceasing this habit, brain perfusion recovers normal pattern. We propose to compare brain perfusion patterns performing brain SPECT scans of smokers and non-smokers. Thirteen volunteers age range 20-30 years old) composed of six non-smokers and seven smokers were studied by brain scans (SPECT).We used ECD- {sup 99m} Tc radiolabelled as recommended by the manufacturer. All patients received 740 MBq of the radiopharmaceutical through intravenous injection, with their eyes opened and their ears unplugged, in a quiet room. We used a one head SPECT camera ( General Electric/ StarCam 4000 and Siemens/ E.Cam) with low-energy ultrahigh resolution collimator. Imaging begin 40 minutes after tracer injection. For reconstruction we used a Butterworth filter.The preliminary results showed brain perfusion deficit areas on five of the smokers while all non- smokers had normal brain perfusion scans. We believe that smoking increases the possibility of brain perfusion deficits. (author)

  9. Evaluation of {sup 99m}Tc-ECD SPECT for the detection of brain tumor. Comparison with {sup 201}Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Motoo; Sasaki, Yasushi; Kikuchi, Yoshirou; Kaminaga, Tatsuro; Furui, Shigeru [Teikyo Univ., Tokyo (Japan). Faculty of Medicine; Konoeda, Kouichi; Karigome, Masato; Yoshida, Katsuhiko

    1997-01-01

    For the evaluation of brain tumor (n=15), we performed both dynamic and static {sup 99m}Tc-ECD (ECD) SPECT studies. {sup 201}Tl SPECT was also used for comparison with the results of ECD SPECT. Dynamic ECD SPECT was obtained following the injection of 600 MBq of ECD. Five min after the injection of ECD, static ECD SPECT was performed. {sup 201}Tl SPECT was obtained 10 min after the injection of 74 MBq. Abnormal uptake was recognized in 7 of 15 tumors with dynamic ECD; 5 of 7 meningiomas, 1 of 1 glioblastoma and 1 of 1 astrocytoma. However, no abnormal uptake was seen in 3 of 3 benign tumors (1 low grade astrocytoma, 1 hemangioma, 1 craniopharyngioma) and in 2 of 2 brain metastases. In contrast abnormal uptake was seen in 11 of 15 tumors with {sup 201}Tl; 7 of 7 meningiomas, 2 of 2 brain metastases, 1 of 1 glioblastoma and 1 of 1 craniopharyngioma. No abnormal uptake was seen in 3 of 3 benign tumors (1 hemangioma and 2 low grade astrocytomas). Equivocal uptake was seen in 1 low grade astrocytoma with dynamic ECD and {sup 201}Tl. The mechanism of the accumulation of dynamic ECD to brain tumor is unclear. However, it may reflect not only blood flow, but also metabolism. (author)

  10. Clinical assessment of SPECT/CT co-registration image fusion

    International Nuclear Information System (INIS)

    Zhou Wen; Luan Zhaosheng; Peng Yong

    2004-01-01

    Objective: Study the methodology of the SPECT/CT co-registration image fusion, and Assessment the Clinical application value. Method: 172 patients who underwent SPECT/CT image fusion during 2001-2003 were studied, 119 men, 53 women. 51 patients underwent 18FDG image +CT, 26 patients underwent 99m Tc-RBC Liver pool image +CT, 43 patients underwent 99mTc-MDP Bone image +CT, 18 patients underwent 99m Tc-MAA Lung perfusion image +CT. The machine is Millium VG SPECT of GE Company. All patients have been taken three steps image: X-ray survey, X-ray transmission and nuclear emission image (Including planer imaging, SPECT or 18 F-FDG of dual head camera) without changing the position of the patients. We reconstruct the emission image with X-ray map and do reconstruction, 18FDG with COSEM and 99mTc with OSEM. Then combine the transmission image and the reconstructed emission image. We use different process parameters in deferent image methods. The accurate rate of SPECT/CT image fusion were statistics, and compare their accurate with that of single nuclear emission image. Results: The nuclear image which have been reconstructed by X-ray attenuation and OSEM are apparent better than pre-reconstructed. The post-reconstructed emission images have no scatter lines around the organs. The outline between different issues is more clear than before. The validity of All post-reconstructed images is better than pre-reconstructed. SPECT/CT image fusion make localization have worthy bases. 138 patients, the accuracy of SPECT/CT image fusion is 91.3% (126/138), whereas 60(88.2%) were found through SPECT/CT image fusion, There are significant difference between them(P 99m Tc- RBC-SPECT +CT image fusion, but 21 of them were inspected by emission image. In BONE 99m Tc -MDP-SPECT +CT image fusion, 4 patients' removed bone(1-6 months after surgery) and their relay with normal bone had activity, their morphologic and density in CT were different from normal bones. 11 of 20 patients who could

  11. Study on the primary visual cortex of visually impaired subjects by means of 123I-IMP SPECT and MRI

    International Nuclear Information System (INIS)

    Ishikawa, Nobuyoshi; Satou, Motohiro; Takeda, Tohoru; Itai, Yuji; Nishijo, Kazushi.

    1995-01-01

    We conducted a study of rCBF in the primary visual cortex of visually impaired subjects who have not been subjected to external stimulation for a long period, by means of 123 I-IMP SPECT and MRI. The four subjects had lost their sight due to brain tumors (n=2), glaucoma (n=1) and trauma (n=1). 123 I-IMP SPECT showed no differences between the visually impaired group and a visually sound control group on visual analysis as well as semiquantitative analysis. MRI of the visually impaired subjects showed no organic changes, such as atrophy, in the occipital cortex. In conclusion, visually impaired subjects have no decrease in rCBF and no anatomical changes in the primary visual cortex. (author)

  12. Interest of hybrid SPECT-CT imaging for diagnosis of infection

    International Nuclear Information System (INIS)

    Riviere, A.; Farid, K.; Guyot, M.; Jeandot, R.; Allard, M.; Fernandez, P.; Clermont, H. de; Dauchy, F.; Dupon, M.; Fernandez, P.

    2008-01-01

    Single-Photon Emission Computed Tomography-Computerized Tomography (SPECT-CT) is a new hybrid technique which offers new diagnostic capabilities in daily nuclear medicine practice. This technique not only allows to acquire merged anatomic and functional images in the same time, but also, it increases sensitivity and accuracy of SPECT thanks to attenuation and scattering corrections got from transmission data. Until now, SPECT-CT data have been mainly obtained in oncology and cardiology, but now, many authors use it in many scan studies and particularly for infectious diseases. In inflammatory bowel diseases, SPECT-CT seems to increase diagnostic performances and to modify management of many patients. In suspected vascular sepsis, SPECT-CT could increase sensitivity of white blood cell scintigraphy but also its specificity thanks to spatial resolution of CT. In osteo-articular sepsis, SPECT-CT has the advantage to distinguish osteomyelitis from soft tissue infection and to guide biopsies. Nevertheless, in the light of PET-CT works, SPECT-CT development will probably modify nuclear medicine practice and many studies have to be conducted to highlight consensual procedure guidelines. (authors)

  13. Diagnostic impact of SPECT-CT in the assessment of endocrine tumors

    International Nuclear Information System (INIS)

    El Badaoui, A.; Clermont, H. de; Valli, N.; Caignon, J.M.; Fernandez, P.; Allard, M.; Barat, J.L.; Ducassou, D.; Clermont, H. de; Valli, N.; Caignon, J.M.; Fernandez, P.; Allard, M.; Barat, J.L.; Ducassou, D.; Clermont, H. de; Allard, M.

    2008-01-01

    Image fusion using single photon emission computed tomography - computed tomography (SPECT - CT) associates functional and morphological images. This study evaluates the added value of SPECT- CT, obtained with a hybrid SPECT- CT gamma camera, on anatomic localization and diagnostic impact in assessment of endocrine tumours and pheochromocytomas. Method: Six months prospective study was undertaken including 33 consecutive exams encompassing 20 Somatostatin Receptor Scintigraphies (S.R.S.) and 13 123 I-meta-iodo-benzyl-guanidine (Mibg) scans. Two experienced nuclear medicine physicians independently analysed independently planar and SPECT images in a first time, then, SPECT- CT fused images in a second time. They evaluated two parameters: SPECT- CT impact on anatomic localization (L.A.) and its diagnostic impact (I.D.). Each parameter was scored according three levels of evaluation. Results: An added value of SPECT- CT images was evidenced in 55% of cases on the anatomic localization and in 41% of the patients on the diagnostic impact. Therefore, a more important benefit was noted when SPECT was positive (L.A.: 90%; I.D.: 70%) than when it was negative (L.A.: 15%; I.D.: 8%). Furthermore, the added value proved higher for the S;R.S. compared to Mibg scans. Conclusion: SPECT- CT fusion images obtained by a hybrid system is more relevant to determine anatomic localization and more accurate than SPECT alone, particularly in the assessment of endocrine tumours. The added value of SPECT- CT seems to be lower for Mibg scans in the assessment of pheochromocytomas. (authors)

  14. Right prefrontal rTMS treatment for refractory auditory command hallucinations - a neuroSPECT assisted case study.

    Science.gov (United States)

    Schreiber, Shaul; Dannon, Pinhas N; Goshen, Elinor; Amiaz, Revital; Zwas, Tzila S; Grunhaus, Leon

    2002-11-30

    Auditory command hallucinations probably arise from the patient's failure to monitor his/her own 'inner speech', which is connected to activation of speech perception areas of the left cerebral cortex and to various degrees of dysfunction of cortical circuits involved in schizophrenia as supported by functional brain imaging. We hypothesized that rapid transcranial magnetic stimulation (rTMS), by increasing cortical activation of the right prefrontal brain region, would bring about a reduction of the hallucinations. We report our first schizophrenic patient affected with refractory command hallucinations treated with 10 Hz rTMS. Treatment was performed over the right dorsolateral prefrontal cortex, with 1200 magnetic stimulations administered daily for 20 days at 90% motor threshold. Regional cerebral blood flow changes were monitored with neuroSPECT. Clinical evaluation and scores on the Positive and Negative Symptoms Scale and the Brief Psychiatric Rating Scale demonstrated a global improvement in the patient's condition, with no change in the intensity and frequency of the hallucinations. NeuroSPECT performed at intervals during and after treatment indicated a general improvement in cerebral perfusion. We conclude that right prefrontal rTMS may induce a general clinical improvement of schizophrenic brain function, without directly influencing the mechanism involved in auditory command hallucinations.

  15. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  16. Editorial 3/2015: Handeln mit Symbolen

    Directory of Open Access Journals (Sweden)

    Alessandro Barberi

    2015-09-01

    Full Text Available Die paradigmatische Unterscheidung zwischen Sozial- und Kulturwissenschaften, die spätestens seit den 1980er Jahren eingehend diskutiert wurde, lässt sich anhand des Bereichs des Symbolischen auf den Punkt bringen: Ist das Symbolische nur ein Effekt von sozialen, ökonomischen oder medialen Strukturen einer gegebenen Gesellschaft oder reproduzieren sich Strukturen nur durch die symbolischen Handlungen der AkteurInnen innerhalb einer gegebenen Kultur? So hatte etwa der klassische "harte" Strukturalismus bei Claude Lévi-Strauss, Jacques Lacan und dem frühen Michel Foucault symbolische Ordnungen (und d. i. hier die Sprache als eine unbewusst determinierende Voraussetzung von menschlicher Interaktion begriffen, woraufhin mit dem Post- bzw. Neostrukturalismus die Rückkehr der individuellen Äußerung, der parole, des speech acts (und d. i. hier das Sprechen, also der symbolischen Handlung in den Mittelpunkt rückte. Medienpädagogisch ist diese Unterscheidung gerade dann von Interesse, wenn es darum geht, wie Lehrende und Lernende sich zueinander verhalten, interagieren und dabei eben mit Symbolen handeln. Insofern ist es bemerkenswert, dass – fast parallel zu Foucaults Unterscheidung von diskursiven und nicht-diskursiven Praktiken – auch Dieter Baacke 1973 von diskursiven und nicht-diskursiven Symbolen gesprochen hat. Denn – wie auch im Rahmen des "Symbolischen Interaktionismus" von George Herbert Mead argumentiert wurde – können Symbole nur im Rahmen einer gegebenen Diskursökonomie von AkteurInnen diskursiv ausgetauscht werden und konstituieren dabei Erfahrungen bzw. Wahrnehmungen und somit auch die soziale bzw. kulturelle Wirklichkeit. Insofern ist die Frage nach dem Symbolischen immer auch eine Frage nach den Möglichkeiten der Handlungstheorie (im Sinne Jürgen Habermas’ bzw. der Praxeologie (im Sinne Pierre Bourdieus. Die Redaktion der MEDIENIMPULSE geht in diesem Zusammenhang theoretisch und praktisch von Entscheidungsimpulse

  17. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  18. SPECT and PET imaging in epilepsia; SPECT und PET in der Diagnostik von Epilepsien

    Energy Technology Data Exchange (ETDEWEB)

    Landvogt, C. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2007-09-15

    In preoperative localisation of epileptogenic foci, nuclear medicine diagnostics plays a crucial role. FDG-PET is used as first line diagnostics. In case of inconsistent MRI, EEG and FDG-PET findings, {sup 11}C-Flumazenil-PET or ictal and interictal perfusion-SPECT should be performed. Other than FDG, Flumazenil can help to identify the extend of the region, which should be resected. To enhance sensitivity and specificity, further data analysis using voxelbased statistical analyses or SISCOM (substraction ictal SPECT coregistered MRI) should be performed.

  19. Tc-99m MAG3 SPECT on transplanted kidney

    International Nuclear Information System (INIS)

    Ryu, Jong Gul; Kim, Soon; Zeon, Seok Kil

    1999-01-01

    This study was designed to evaluate the usefulness of a technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) single photon emission computed tomography (SPECT) performed on transplanted kidney. Thirty renal transplant patients were included in this study. Planar scan was performed for 30 minutes using 555 MBq Tc-99m MAG3. A post-voiding SPECT scan was acquired on the third, seventh, fourteenth and twenty eighth day after transplantation. SPECT scan showed interpretable image quality in 26 of 30 patients (86.7%) and 84 in 120 scans (70%). Fourteen of 26 patients with interpretable SPECT image showed decreased or increased radioactivity, but only 5 had abnormal findings on the planar scan. Focal SPECT defects were seen in allografts with normal function (n=3), acute tubular necrosis (n=3), and acute rejection (n=2). The defects are thought to reflect focally underperfused renal parenchyme or, in normal allografts, an artifact from uneven radioactivity distribution. Four of 10 paints with renal arterial variation showed focally decreased radioactivity and SPECT helped guide further studies that confirmed the exact cause. Five of 10 patients with acute tubular necrosis or acute rejection showed focally decreased radioactivity, but its relation to the patients' clinical course was not clear. Focally increased radioactivity was observed in 5 allografts with normal function and 1 with double ureter in which local clearance delay was observed. Tc-99m MAG3 SPECT renal scan can detect additional focal abnormalities compared to planar scan. Further study is necessary to elucidate the exact clinical significance of the SPECT findings

  20. Mit kokkeri

    DEFF Research Database (Denmark)

    Ejlersen, Søren; Lorang, Louisa

    MIT kokkeri er resultatet af et samarbejde mellem Komiteen for Sundhedsoplysning, Institut for Uddannelse og Pædagogik/Aarhus Universitet og Haver til Maver. Projektet støttes af Nordea-fonden. Bag kogebogens mange opskrifter står en række erfarne madeksperter bestående af Søren Ejlersen, Louisa...