WorldWideScience

Sample records for hmpao spect imaging

  1. HMPAO-SPECT during epileptic seizures: Early and late images

    International Nuclear Information System (INIS)

    Overbeck, B.; Gruenwald, F.; Bockisch, A.; Biersack, H.J.; Reinke, U.; Gratz, K.F.

    1990-01-01

    For presurgical evaluation of epilepsy a 44-year old patient with complex-partial seizures underwent HMPAO-SPECT. The morphology of the seizures, the MRI-scan, psychometry and ictal as well as interictal EEGs showed a left temporal origin of the seizures. Early images were obtained 20 min and late images 24 h following injection. On both scans a marked hyperperfusion was observed in the left temporal area. A crossed cerebellar diaschisis was also seen on both SPECTs. It could be shown that during ictal examinations there is no bloodflow-dependent wash-out from brain tissue. (orig.) [de

  2. Value of Tc-99m HMPAO SPECT imaging in patients with TIA or acute stroke and normal CT

    International Nuclear Information System (INIS)

    Koster, K.; Brass, L.M.; Hoffer, P.B.; Gottschalk, A.; Smith, E.O.; Rehm, P.K.

    1988-01-01

    To determine the value of Tc-99m HMPAO single photon emission CT (SPECT) imaging, 51 patients with transient, acute, or chronic cerebrovascular disease were studied. Seventeen patients presented with recent transient ischemic attack (TIA) or acute stroke and underwent SPECT imaging and CT within 72 hours of presentation. SPECT image interpretation was independent of clinical history and CT findings. Four patients with acute stroke and eight patients with TIA had normal CT findings. All patients with acute stroke (three nonlacunar, one lacunar infarct) and three of eight patients with TIA also showed perfusion abnormalities on Tc-99m HMPAO scans. Thus, Tc-99m HMPAO SPECT may be useful in the early diagnosis and subtype determination of acute stroke and in the evaluation of TIA

  3. Differential diagnosis of regional cerebral hyperfixation of TC-99m HMPAO on SPECT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shirazi, P.; Konopka, L.; Crayton, J.W. [Loyola Univ. Medical Center, Maywood, IL (United States)] [and others

    1994-05-01

    Accurate diagnostic evaluation of patients with neurologic and neuropsychiatric disease is important because early treatment may halt disease progression and prevent impairment or disability. Cerebral hyperfixation of HMPAO has been ascribed to luxury perfusion following ischemic infarction. The present study sought to identify other conditions that also display radiotracer hyperfixation in order to develop a differential diagnosis of this finding on SPECT imaging. Two hundred fifty (n=250) successive cerebral SPECT images were reviewed for evidence of HMPAO hyperfixation. Hyperfixation was defined as enhanced focal perfusion surrounded by a zone of diminished or normal cerebral perfusion. All patients were scanned after intravenous injection of 25 mCi Tc-99m HMPAO. Volume-rendered and oblique images were obtained with a Trionix triple-head SPECT system using ultra high resolution fan beam collimators. Thirteen (13/250; 5%) of the patients exhibited regions of HMPAO hyperfixation. CT or MRI abnormalities were detected in 6/13 cases. Clinical diagnoses in these patients included intractable psychosis, post-traumatic stress disorder, alcohol and narcotic dependence, major depression, acute closed-head trauma, hypothyroidism, as well as subacute ischemic infarction. A wide variety of conditions may be associated with cerebral hyperfixation of HMPAO. These conditions include neurologic and psychiatric diagnoses, and extend the consideration of hyperfixation beyond ischemic infarction. Consequently, a differential diagnosis of HMPAO hyperfixation may be broader than originally considered, and this may suggest a fundamental role for local cerebral hyperperfusion. Elucidation of the fundamental mechanism(s) for cerebral hyperperfusion requires further investigation.

  4. Brain perfusion SPECT imaging before and during the acetazolamide test using sup 99m Tc-HMPAO

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Higashi, Sotaro; Kinuya, Keiko; Tsuji, Shiro; Sumiya, Hisashi; Hisada, Kinichi; Yamashita, Junkoh (Kanazawa Univ. (Japan). School of Medicine)

    1990-05-01

    A new method using brain perfusion {sup 99m}Tc-HMPAO SPECT imaging was developed for evaluating cerebral perfusion reserve by the acetazolamide test with a short period. The first SPECT study was carried out for 13.5 min to obtain SPECT images at the resting state after 3 min postinjection of 555 MBq (15 mCi) of {sup 99m}Tc-HMPAO. At the same time as the start of the first SPECT study, 1 g of acetazolamide was intravenously injected. Immediately after the stop of the 1st SPECT study, 925 MBq (25 mCi) of {sup 99m}Tc-HMPAO from the same vial as in the first study was additionally injected. Three minutes later the second SPECT study was carried out for 10 min. After reconstruction the tomographic images in the first study were subtracted from the images in the second study to obtain those during the acetazolamide test after correction of the time differences in data acquisition between the two studies. This subtraction technique gives independent brain perfusion SPECT images before and during the acetazolamide test. Besides, the regional flow changes during the test were quantitatively analyzed. In conclusion this method seems to be practically useful for evaluating regional brain perfusion before and during drug treatments as a consecutive study with a short period of approximately 30 min. (author).

  5. Is SPECT useful in imaging of abdominal inflammatory processes using 99mTc-HMPAO-WBCs?

    International Nuclear Information System (INIS)

    Smole, M.S.; Stantic, T.S.; Fettich, J.F.

    2002-01-01

    Aim: The aim of the study is to determine whether SPECT gives additional information in the assessment of inflammation of the abdominal region with labelled white blood cells as compared with usual planar imaging. Patients And Methods: SPECT and planar imaging was performed in 26 patients with suspected inflammatory process in the abdomen, within three hours after injection of autologous white blood cells labelled with 99m Tc HMPAO. Planar images where acquired as static spot images using high resolution low energy collimator on 256 x 256 matrix. SPECT was performed using the same collimator on 128 x 128 matrix in 128 projections. Filtered back projection was used for reconstruction and volume rendering was performed. Results: The lesions in the abdomen were classified as jejunum, colon ascendents, colon transversum, colon descendents, sigmoid, and lesions outside GIT. All lesions, which were seen on planar images, except one, were also seen on SPECT. Five equivocal lesions seen on planar images were reconfirmed as pathological on SPECT. Additionally SPECT revealed three lesions not seen on planar images. Fourteen lesions were seen by both imaging techniques. All together SPECT improved diagnostic accuracy of 99m Tc - HMPAO - WBC scintigraphy in 7/28 patients. Conclusion: more inflammatory lesions in the abdomen are revealed by SPECT and volume rendering, than by planar imaging equivocal lesions seen on planar images can be characterised as positive or negative by SPECT. SPECT artefacts can cause possible false positive results; therefore usual planar imaging cannot be omitted if SPECT is performed

  6. HMPAO-SPECT in cerebral seizures

    International Nuclear Information System (INIS)

    Gruenwald, F.; Bockisch, A.; Reichmann, K.; Ammari, B.; Hotze, A.; Biersack, H.J.; Durwen, H.; Buelau, P.; Elger, C.E.; Rohde, A.; Penin, H.

    1988-01-01

    In nine patients with suspected psychogenic seizures and in three patients with proven epileptic seizures HMPAO-SPECT was performed prior to and during seizure. In the patients with lateron-proven psychogenic seizures no, or only slight, changes of regional cerebral blood flow were found. Patients with proven epilepsy revealed partly normal findings interictally but during seizure a markedly increased circumscript blood flow was found in all patients. Even though PET is superior to SPECT with respect to spatial resolution, in the diagnosis of seizures HMPAO-SPECT has the advantage of enabling injection of the tracer during the seizure and the performance of the SPECT study subsequently. (orig.) [de

  7. 99mTc-HMPAO Brain SPECT in Patients with Post-Traumatic Organic Mental Disorder

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Lee, Dong Jin; Shong, Min Ho; Kang, Min Hee; Ghi, Ick Sung; Shin, Young Tai; Ro, Heung Kyu

    1994-01-01

    It is well known that 99m Tc-HMPAO brain SPECT can reflect the functional lesions better than X-ray computerized tomography(CT) and magnetic resonance imaging(MRI) in the cerebral disorders. In order to evaluate the clinical utilities of 99m Tc-HMPAO brain SPECT in patients with post-traumatic chronic organic mental disorder(OMD). We included 28 patients diagnosed as OMD in department of psychiatry after traumatic head injury. And we compared the results of 99m Tc-HMPAO SPECT with those of MRI, EEG and MINI mental status examination(MMSE). The results were as follows 1) All patients diagnosed as OMD showed diffuse or focal decreased cerebral perfusion on 99m Tc-HMPAO SPECT. 2) Most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT showing normal brain MRI result was also decreased both frontal perfusion. 3) Eight of 28 patients showed focal brain MRI lesions(4 small frontal hygroma, 3 small cerebral infarction and 1 cerebellar encephalomalacia) which were not detected in brain 99m Tc-HMPAO SPECT. 4) The patients showing less than 20 points on MMSE disclosed abnormal results of EEG more frequently than those disclosing more than 20 points. In conclusion, we think that 99m Tc-HMPAO brain SPECT is sensitive method to detect functional lesions of the brains in patients with chronic post-traumatic organic mental disorder.

  8. SPECT with [99mTc]-d,l-hexamethyl-propylene amine oxime (HM-PAO) compared with regional cerebral blood flow measured by PET

    DEFF Research Database (Denmark)

    Yonekura, Y; Nishizawa, S; Mukai, Thomas Søgaard

    1988-01-01

    In order to validate the use of technetium-99m-d,l-hexamethylpropyleneamine oxime (HM-PAO) as a flow tracer, a total of 21 cases were studied with single photon emission computerized tomography (SPECT), and compared to regional cerebral blood flow (rCBF) measured by position emission tomography...... (PET) using the oxygen-15 CO2 inhalation technique. Although HM-PAO SPECT and rCBF PET images showed a similar distribution pattern the HM-PAO SPECT image showed less contrast between high and low activity flow regions than the rCBF image and a nonlinear relationship between HM-PAO activity and r......CBF was shown. Based on the assumption of flow-dependent backdiffusion of HM-PAO from the brain, we applied a "linearization algorithm" to correct the HM-PAO SPECT images. The corrected HM-PAO SPECT images revealed a good linear correlation with rCBF (r = 0.901, p less than 0.001). The results indicated HM-PAO...

  9. Comparison of Tc-99m HM-PAO SPECT brain scan and x-ray CT in the detection of brain metastases

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.M.; Sadek, S.; Sahwell, A.; Kubasek, H.; El-Sayed, M.; Ziada, G.; Mobarak, L.; Al-Huda, F.; Omar, Y.T.

    1986-01-01

    Tc-99m HM-PAO imaging was compared with x-ray CT in 14 patients with known or suspected brain metastases. Both studies were done within 3 days of each other. Static and single photon emission CT (SPECT) images were acquired after intravenous injection of 13 mCi of Tc-99m HM-PAO. All 14 patients underwent static and SPECT Tc-99m HM-PAO imaging and x-ray CT. Studies were positive in 7, 12, and 10 patients, respectively, by static, SPECT, and x-ray CT imaging, and negative in 7, 2, and 2. The number of lesions identified was 0 (static imaging), 32 (SPECT), and 26(x-ray CT). There were no ''suspicious'' studies by any modality. This study indicates that Tc-99m HM-PAO SPECT cerebral blood flow imaging is more sensitive than x-ray CT for detecting brain metastases, that biplane imaging is not sensitive and SPECT is essential, and that for Tc-99m HM-PAO SPECT brain imaging to regain its importance with respect to x-ray CT, acquisition time must be 10 minutes or less and determination of percentage brain uptake of the injected dose, and of regional distribution, is necessary

  10. HM-PAO SPECT in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Cordes, M.; Rummeny, E.; Reissmann, M.; Fox, K.; Panitz, N.; Pfannenstiel, P.

    1987-01-01

    Single photon emission computed tomography (SPECT) after injection of 99m-Tc-HM-PAO was used to examine 34 patients whose clinical findings could not exclude a cerebrovascular disease. In all patients an X-ray computed tomography examination was inconclusive for the clinical-neurological findings. The regional cerebral bloodflow was pathologically disturbed in 10 of 34 patients in the HM-PAO SPECT examination. The detection of the regional cerebral bloodflow with HM-PAO SPECT is helpful in the diagnosis of cerebrovascular disease. (orig.) [de

  11. 99mTc-HMPAO SPECT in pediatric patients with neurological disorders

    International Nuclear Information System (INIS)

    Yamaoka, Mitsuko

    1994-01-01

    In 125 pediatric patients with suspected brain diseases, EEG, CT and MRI findings were compared with those obtained with single photon emission computed tomography (SPECT) of the brain using Tc-99m-d, 1-hexamethyl-propylene amine oxime ( 99m Tc-HMPAO), to determine the usefulness of SPECT as an adjunct to EEG, CT and MRI in this age group. The incidences of abnormal finding in the 125 patients were 53.6, 75.2, 60.6 and 51.4% using 99m Tc-HMPAO SPECT, EEG, CT and MRI respectively. In localization-related epilepsy and cerebrovascular diseases, the incidence of abnormality was higher with 99m Tc-HMPAO SPECT than with either CT or MRI. There was a tendency for mean age to be higher and mean IQ or DG lower in patients with more extensive abnormality in comparison to those who had normal or only focally abnormal SPECT findings. Nevertheless, some patients showed focal hypofusion in the frontal or occipital area without significant mental retardation. Epileptic foci detected by EEG corresponded to defects found using 99m Tc-HMPAO SPECT in 34.8% of the symptomatic localization-related epileptic patients. Pathological lesions detected by CT or MRI corresponded with SPECT findings in 48.1% of patients. Furthermore, the incidence of abnormal findings on SPECT was 30% in patients in whom CT or MRI was normal. Epileptic foci detected by EEG did not correspond well with the area of focal hyperfusion found on SPECT. Focal hyperfusion may sometimes occur even in the interictal period or postictal period in childhood seizure disorders. In conclusion, 99m Tc-HMPAO SPECT revealed abnormal findings at a moderate incidence in neuropediatric patients. Correlations with EEG, CT and MRI findings as well as assessment of clinical signs, including the investigation of epileptic foci, are essential for adequate interpretation of brain functions. (author)

  12. A new method for brain functional study using Tc-99m HMPAO SPECT

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Ohtake, Tohru; Watanabe, Toshiaki; Iio, Masahiro

    1989-01-01

    The distribution of 99m Tc-HMPAO in brain is in proportion to regional cerebral blood flow (rCBF) and can be interpreted as functional mapping. To evaluate local changes in CBF during neuropsychological testing, we developed a new subtraction method using HMPAO and SPECT. With patients resting, 15 mCi of HMPAO was injected and the first acquisition was performed, lasting a total of 10 minutes. Soon after the end of the first scan, patients were requested to undergo Buschke's memory test or to repeat words or numbers (repetition test). During the task, an additional 15 mCi of HMPAO was injected using the same position as in the first scan, and a second acquisition was started. A functional image was made by subtracting the image in the first scan from that in the second. In two patients with transient global amnesia and two normal controls, Buschke's memory test was performed in combination with SPECT. A relative increase in activity was seen in the thalamus, subthalamic area, hippocampus, and some cortial areas, apparently reflecting local functional change induced by the memory task. In two patients with moderate Alzheimer's disease with severe memory loss, no increase was detected in these areas. In one patient with aphasia, the repetition test with SPECT was correlated with the WADA test and dichotic listening test, and good agreement was obtained. In conclusion, our new SPECT technique is useful in detecting alterations in rCBF during mental activity and can be applied to neurophysiological studies. (author)

  13. A new method for brain functional study using Tc-99m HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Ohtake, Tohru; Watanabe, Toshiaki; Iio, Masahiro (Tokyo Univ. (Japan). Faculty of Medicine)

    1989-04-01

    The distribution of {sup 99m}Tc-HMPAO in brain is in proportion to regional cerebral blood flow (rCBF) and can be interpreted as functional mapping. To evaluate local changes in CBF during neuropsychological testing, we developed a new subtraction method using HMPAO and SPECT. With patients resting, 15 mCi of HMPAO was injected and the first acquisition was performed, lasting a total of 10 minutes. Soon after the end of the first scan, patients were requested to undergo Buschke's memory test or to repeat words or numbers (repetition test). During the task, an additional 15 mCi of HMPAO was injected using the same position as in the first scan, and a second acquisition was started. A functional image was made by subtracting the image in the first scan from that in the second. In two patients with transient global amnesia and two normal controls, Buschke's memory test was performed in combination with SPECT. A relative increase in activity was seen in the thalamus, subthalamic area, hippocampus, and some cortial areas, apparently reflecting local functional change induced by the memory task. In two patients with moderate Alzheimer's disease with severe memory loss, no increase was detected in these areas. In one patient with aphasia, the repetition test with SPECT was correlated with the WADA test and dichotic listening test, and good agreement was obtained. In conclusion, our new SPECT technique is useful in detecting alterations in rCBF during mental activity and can be applied to neurophysiological studies. (author).

  14. Improvement of Cerebral Hypoperfusion with Levothyroxine Therapy in Hashimoto's Encephalopathy Demonstrated by 99mTc-HMPAO-SPECT

    Science.gov (United States)

    Schnedl, Wolfgang J.; Mirzaei, Siroos; Wallner-Liebmann, Sandra J.; Tafeit, Erwin; Mangge, Harald; Krause, Robert; Lipp, Rainer W.

    2013-01-01

    Background Hashimoto's encephalopathy (HE) is a rare immune-mediated encephalopathy associated with autoimmune Hashimoto's thyroiditis. Objectives and Methods We report on a patient with HE and significant clinical improvement correlating with an increase in cerebral blood flow demonstrated by hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). HMPAO-SPECT was performed with 740 MBq of technetium-99m-HMPAO. To demonstrate the improvement in regional cerebral blood flow, individual regions of interest were drawn around visually diminished HMPAO uptake, the lesion to reference region ratio was calculated and transverse section images and semi-quantitative measurements were performed. Results We show a 5-year follow-up with significant clinical improvement, a 10-fold reduction in autoantibodies to thyroid peroxidase and an approximately 20% improvement in cerebral blood flow with HMPAO-SPECT. Conclusion Adequate levothyroxine treatment achieving and maintaining euthyroidism should be considered as therapy to lower autoantibodies and improve clinical outcome in patients with Hashimoto's thyroiditis and encephalopathy. PMID:24783049

  15. Functional imaging studies of cognition using 99mTc-HMPAO SPECT: empirical validation using the n-back working memory paradigm

    International Nuclear Information System (INIS)

    Ludwig, Catherine; Ribaupierre, Anik de; Chicherio, Christian; Terraneo, Luc; Magistretti, Pierre; Slosman, Daniel

    2008-01-01

    Functional activation protocols are widely applied for the study of brain-cognition relations. Only few take advantage of the intrinsic characteristics of SPECT, particularly those allowing cognitive assessment outside of the camera, in settings close to the standard clinical or laboratory ones. The purpose of the study was to assess the feasibility of a split-dose activation protocol with 99m Tc-HMPAO using low irradiation dose. A two-scans protocol was applied to 12 healthy young volunteers using 270 MBq of 99m Tc-HMPAO per scan, with each image associated to a particular experimental condition of the verbal n-back working memory task (0-back, 2-back). Subtraction method was used to identify regional brain activity related to the task. Voxel-wise statistical analysis showed left lateralized activity associated with the 2-back task, compared to the 0-back task. Activated regions, mainly prefrontal and parietal, were similar to those observed in previous fMRI and 15 O-PET studies. The results support the use of 99m Tc-HMPAO SPECT for the investigation of brain-cognition relations and demonstrate the feasibility of optimal quality images despite low radiopharmaceutical doses. The findings also acknowledge the use of HMPAO as a radioligand to capture neuro-energetic modulations linked to cognitive activity. They encourage extending the application of the described activation protocol to clinical populations. (orig.)

  16. Topodiagnosis in Creutzfeldt-Jakob disease by HMPAO-SPECT. Topodiagnostik der Creutzfeldt-Jakobschen Krankheit durch HMPAO-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Heye, N. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Farahati, J. (Klinik und Poliklinik fuer Nuklearmedizin, Essen Univ. (Gesamthochschule) (Germany)); Heinz, A. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Buettner, T. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Przuntek, H. (Neurologische Klinik, St. Josef Hospital, Bochum Univ. (Germany)); Reiners, C. (Klinik und Poliklinik fuer Nuklearmedizin, Essen Univ. (Gesamthochschule) (Germany))

    1993-02-01

    A 80-year old female presented with an early stage of Creutzfeldt-Jakob disease with clinical, neurophysiological and neuropathological findings suggesting a focal involvement of the brain. HMPAO SPECT disclosed asymmetries of regional cerebral perfusion, thus suggesting that it may be a further diagnostic instrument in this disease. (orig.)

  17. Usefulness of hybrid SPECT/CT for the 99mTc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Directory of Open Access Journals (Sweden)

    Chiara Bruni

    Full Text Available Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC with 99mTc-hexamethylpropylene amine oxime (HMPAO has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. 99mTc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of99mTc-HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with 99mTc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection.

  18. Surface and volume three-dimensional displays of Tc-99m HMPAO brain SPECT images in stroke patients with three-head gamma camera

    International Nuclear Information System (INIS)

    Shih, W.J.; Slevin, J.T.; Schleenbaker, R.E.; Mills, B.J.; Magoun, S.L.; Ryo, U.Y.

    1991-01-01

    This paper evaluates volume and surface 3D displays in Tc-99m HMPAO brain SPECT imaging in stroke patients. Using a triple-head gamma camera interfaced with a 64-bit supercomputer, 20 patients with stroke were studied. Each patient was imaged 30-60 minutes after an intravenous injection of 20 mCi of Tc-99m HMPAO. SPECT images as well as planar images were routinely obtained; volume and surface 3D display then proceeded, with the process requiring 5-10 minutes. Volume and surface 3D displays show the brain from all angles; thus the location and extension of lesion(s) in the brain are much easier to appreciate. While a cerebral lesion(s) was more clearly delineated by surface 3D imaging, crossed cerebellar diaschisis in seven patients was clearly exhibited with volume 3D but not with surface 3D imaging. Volume and surface 3D displays enhance continuity of structures and understanding of spatial relationships

  19. 99mTc-HMPAO SPECT thalamic blood flow study in migraine

    International Nuclear Information System (INIS)

    Zhang Zhijian; Steiner, T.J.

    1995-01-01

    The changes of blood flow in the thalamic of migraineurs by 99m Tc-HMPAO SPECT imaging are investigated. 60 cases with migraine were performed by Novo 810 high-resolution SPECT 30 minutes after injection of 99m Tc-HMPAO. The quantitative analysis of SPECT data was based on the irregular ROI% uptake normalized to total slice method. There were significantly increased mean % uptake values in migraine with aura (259.1 +-17.1), and more significantly in those who experienced hemisensory symptoms and hemiparesis during aura (263.8 +- 17.2), compared to that of migraine without aura (249.1 +- 14.9), but there were not statistically significant difference between migraine with only visual disturbance during aura (255.1 +- 16.4) and without aura. The possible explanations for the increased mean % uptake values in migraineurs who experienced hemisensory symptoms and hemiparesis during aura are: (1) the reactive postischemic hyperemia. (2) excepting thalamus, the regional blood flow was decreased. (3) the secondary phenomenon to the various neurogenic and chemical stimuli

  20. 99mTc-HMPAO Regional Cerebral Blood Flow SPECT in Transient Ischemic Attacks

    International Nuclear Information System (INIS)

    Ahn, Myeong Im; Park, Young Ha; Lee, Sung Yong; Chung, Soo Kyo; Kim, Jong Woo; Bahk, Yong Whee

    1989-01-01

    Transient ischemic attacks (TJAs) is a syndrome resulting from brain ischemia lasting less than 24 hours. The mechanisms of TIAs may be similar to those of cerebral embolism and thrombosis, and thus TIAs may be followed by cerebral infarction. Despite the availability of CT scanning, the diagnosis and management of TIAs continue to be difficult. Recently SPECT has been advocated as a diagnostic imaging modality. We performed 99m Tc-HMPAO regional cerebral blood flow (rCRF) SPECT in 24 patients with the clinical diagnosis of TIAs to assess its ability to detect early changes of rCBF, and determine the diagnostic value. Ten men and fourteen women with an average of 51 years (range; 27-74 years) were included. All but 8 patients had normal brain CT prior to SPECT. The two patients had moderate degree of brain atrophy and the 6 patients nonspecific calcifications. Eighteen of the 24 patients had abnormal 99m Tc-HMPAO rCBF SPECT. Fifteen had unilateral involvement and the other three had bilateral involvements. Seventy-five percents of the defects were found in the left cerebral hemisphere. According to the distribution of the lesions (total number: 34 lesions), fourteen were in the parietal, eight in the temporal, and the remainders were elsewhere. 99m Tc-HMPAO rCHF SPECT is sensitive in detecting rCRF abnormalities in patients with TIAs, and represent the most accurate diagnostic tool available in the diagnosis of TIAs

  1. Functional imaging studies of cognition using {sup 99m}Tc-HMPAO SPECT: empirical validation using the n-back working memory paradigm

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Catherine; Ribaupierre, Anik de [University of Geneva, Center for Interdisciplinary Gerontology, Geneva (Switzerland); Chicherio, Christian [Max Planck Institute for Human Development, Center for Lifespan Psychology, Berlin (Germany); Terraneo, Luc [Geneva University Hospitals, Service of Nuclear Medicine, Geneva (Switzerland); Magistretti, Pierre [EPFL, Brain Mind Institute, Lausanne (Switzerland); Slosman, Daniel [Clinique Generale-Beaulieu, Nuclear Medicine Institute, Geneva (Switzerland)

    2008-04-15

    Functional activation protocols are widely applied for the study of brain-cognition relations. Only few take advantage of the intrinsic characteristics of SPECT, particularly those allowing cognitive assessment outside of the camera, in settings close to the standard clinical or laboratory ones. The purpose of the study was to assess the feasibility of a split-dose activation protocol with {sup 99m}Tc-HMPAO using low irradiation dose. A two-scans protocol was applied to 12 healthy young volunteers using 270 MBq of {sup 99m}Tc-HMPAO per scan, with each image associated to a particular experimental condition of the verbal n-back working memory task (0-back, 2-back). Subtraction method was used to identify regional brain activity related to the task. Voxel-wise statistical analysis showed left lateralized activity associated with the 2-back task, compared to the 0-back task. Activated regions, mainly prefrontal and parietal, were similar to those observed in previous fMRI and {sup 15}O-PET studies. The results support the use of {sup 99m}Tc-HMPAO SPECT for the investigation of brain-cognition relations and demonstrate the feasibility of optimal quality images despite low radiopharmaceutical doses. The findings also acknowledge the use of HMPAO as a radioligand to capture neuro-energetic modulations linked to cognitive activity. They encourage extending the application of the described activation protocol to clinical populations. (orig.)

  2. Usefulness of hybrid SPECT/CT for the {sup 99m}Tc-HMPAO-labeled leukocyte scintigraphy in a case of cranial osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Bruni, Chiara; Padovano, Federico; Travascio, Laura; Schillaci, Orazio; Simonetti, Giovanni [University of Rome Tor Vergata, Rome (Italy). Dept. of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy]. E-mail: chiarabruni79@hotmail.com

    2008-12-15

    Cranial osteomyelitis is a potentially fatal lesion. White blood cell scanning (WBC) with {sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) has proven highly sensitive and specific in the diagnosis and follow-up of patients with suspected osteomyelitis. In this report we show the usefulness of SPECT and transmission CT performed simultaneously using a hybrid imaging device for the functional anatomic mapping of soft tissue and cranial bone infections. {sup 99m}Tc-HMPAO-labeled leukocytes scintigraphy was performed on an elderly diabetic man with an intracranial mass lesion and with suspected temporal bone infection. Planar scans were acquired 30 min, 4 h, and 24 h after injection. SPECT/CT was obtained 6 h after tracer injection, using a dual-head camera coupled with a low-power X-ray tube. The scintigraphic results were matched with the results of surgery and of clinical follow-up. The planar images alone were true-positives for abscess in this patient. SPECT/CT improves the accuracy of {sup 99m}Tc- HMPAO scintigraphy especially in discriminating between soft-tissue and bone involvement. In fact, SPECT/CT also showed temporal bone osteomyelitis. This result indicates that SPECT/CT performed using a hybrid device can improve imaging with {sup 99m}Tc-HMPAO-labeled leukocytes in patients with suspected osteomyelitis by providing accurate anatomic localization and precise definition of the extent of infection. (author)

  3. 99mTc HM-PAO brain perfusion SPECT in brain death

    International Nuclear Information System (INIS)

    Bonetti, M.G.; Ciritella, P.; Valle, G.; Perrone, E.

    1995-01-01

    We have easily carried out and interpreted 99m Tc HM-PAO SPECT in a consecutive series of 40 comatose patients with brain damage, without discontinuing therapy. Brain death was diagnosed in 7 patients, by recognising absence of brain perfusion, as shown by no intracranial radionuclide uptake. In patients in whom perfusion was seen on brain scans, HM-PAO SPECT improved assessment of the extent of injury, which in general was larger than suggested by CT. (orig.)

  4. Technetium-99m-HMPAO SPECT in the evaluation of patients with a remote history of traumatic brain injury: a comparison with x-ray computed tomography.

    Science.gov (United States)

    Gray, B G; Ichise, M; Chung, D G; Kirsh, J C; Franks, W

    1992-01-01

    The functional imaging modality has potential for demonstrating parenchymal abnormalities not detectable by traditional morphological imaging. Fifty-three patients with a remote history of traumatic brain injury (TBI) were studied with SPECT using 99mTc-hexamethylpropyleneamineoxime (HMPAO) and x-ray computed tomography (CT). Overall, 42 patients (80%) showed regional cerebral blood flow (rCBF) deficits by HMPAO SPECT, whereas 29 patients (55%) showed morphological abnormalities by CT. Out of 20 patients with minor head injury, 12 patients (60%) showed rCBF deficits and 5 patients (25%) showed CT abnormalities. Of 33 patients with major head injury, 30 patients (90%) showed rCBF deficits and 24 patients (72%) showed CT abnormalities. Thus, HMPAO SPECT was more sensitive than CT in detecting abnormalities in patients with a history of TBI, particularly in the minor head injury group. In the major head injury group, three patients showed localized cortical atrophy by CT and normal rCBF by HMPAO SPECT. In the evaluation of TBI patients, HMPAO SPECT is a useful technique to demonstrate regional brain dysfunction in the presence of morphological integrity as assessed by CT.

  5. 99mTc-HMPAO SPECT in patients with Alzheimer's disease and multiinfraction dementia

    International Nuclear Information System (INIS)

    Klisarova, A.; Tranulov, G.; Deleva, N.; Kaprelian, A.; Terzieva, M.; Ivanov, B.

    2002-01-01

    Alzheimer's disease (AD) and multiinfarktion dementia (MD) are the commonest causes giving rise to progressive cognitive function deficit in adult individuals. It is the purpose of the study to evaluate 99m Tc-HMPAO SPECT in making the diagnosis and differential diagnosis of Alzheimer's disease and multiinfarction dementia in patients presenting progressive cognitive disorders. Twenty patients with symptoms of dementia divided up in two groups (10 suspected for AD, and 10 with evidence of MD) are subjected to 99m Tc-HMPAO SPECT. To assay the scintigraphic images semi-quantitative perfusion indices are introduced. Bilateral hypoperfusion zones in the temporoparietal and temporal regions are detected in nine AD patients. In 4 of them in advanced stage of the disease hypoperfusion zones are found in the frontal lobe. In 8/10 MD patients vascular dependent hypoperfusion areas are located along the course of vessels. The perfusion indices implemented in practice contribute to the semi-quantitative evaluation of hypoperfusion areas and precise assessment of the scintigraphic findings. 99m Tc-HMPAO SPECT is an atraumatic, noninvasive technique, taken to be the method of choice in making the diagnosis and differential diagnosis of Alzheimer's disease and multiinfarction dementia in routine clinical practice. (authors)

  6. Herpes simplex encephalitis: increased retention of Tc-99m HMPAO on acetazolamide enhanced brain perfusion SPECT

    International Nuclear Information System (INIS)

    Choi, Yun Young; Kim, Kwon Hyung; Kim, Seung Hyun; Cho, Suk Shin

    1998-01-01

    We present an interesting case of herpes simplex encephalitis, which showed increased upta unilateral temporal cortex on brain perfusion SPECT using Tc-99m HMPAO, but in bilateral tem cortex after acetazolamide administration. A 42-year-old man was admitted via emergency room, due to rapidly progressing hea disorientation and mental changes. On neurologic examination, neck stiffness and Kernig sign noted. CSF examination showed pleocytosis with lymphcyte predominance. MRI showed swelling bilateral temporal lobe with left predominance, suggestive of herpes simplex encephalitis. Baseline/ Acetazolamide brain perfusion SPECT were acquired consecutively at the same position IV administration of 740MBq and additional 1480 MBq of Tc-99m HMPAO respectively. The temporal and inferior frontal cortex showed markedly increased perfusion on the baseline acetazolamide-enhanced SPECT images. The right temporal cortex showed normal uptake on the b SPECT images, and markedly increased uptake after acetazolamide administration, which seemed to the abundant vascularity at the acute inflammation site without marked brain damage. The fo brain perfusion SPECT after 6 months showed perfusion defect in left temporal cortex but norm perfusion in right temporal cortex. Therefore, we can conclude that baseline SPECT is helpful for the prediction of the prognosis acetazolamide SPECT for the evaluation of the extent of herpes simples encephalitis

  7. 123I-iomazenil brain receptor SPECT in focal epilepsy. In comparison with 99mTc-HMPAO brain SPECT, MRI and Video/EEG monitoring

    International Nuclear Information System (INIS)

    Xu Hao; Wang Tongge; Huang Li; Michael Cordes

    1998-01-01

    Purpose: To evaluate the clinical value of 123 I-Iomazenil brain receptor SPECT in diagnosis of focal epilepsy in comparison with 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Methods 123 I-Iomazenil brain receptor SPECT was performed on 40 patients with focal epilepsy. The results were compared with those obtained by 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Results: In 40 patients, the sensitivity of Video/EEG monitoring for localization of epileptogenic area was 95% (38/40). The sensitivity of 123 I-iomazenil brain receptor SPECT, 99m Tc-HMPAO brain SPECT and MRI for localization of epileptogenic area compared with Video/EEG monitoring ('gold standard') was 65.8%(25/38), 55.3%(21/38) and 47.4%(18/38), respectively. The localization of epileptogenic area with 123 I-Iomazenil brain receptor SPECT was in concordance with Video/EEG monitoring in 20 patients, 99m Tc-HMPAO brain SPECT in 15 patients and MRI in 16 patients, respectively. The sensitivity of 123 I-Iomazenil brain receptor SPECT combined with MRI for localization of epileptogenic area was 84.2%(32/38). Conclusions: 123 I-Iomazenil brain receptor SPECT is a useful method in detecting and localizing epileptogenic area. The combination of 123 I-Iomazenil brain receptor SPECT and MRI has a high sensitivity for detecting epileptogenic area

  8. Evaluation of the effects of methylprednisolone pulse therapy in patients with systemic lupus erythematosus with brain involvement by Tc-99m HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sun, S.S.; Kao, C.H. [Department of Nuclear Medicine, China Medical University Hospital, Taichung (Taiwan); Huang, W.S. [Department of Nuclear Medicine, National Defense Medical Center, Tri-Service General Hospital, Taipei (Taiwan); Chen, J.J.H. [Section of Rheumatology, Department of Internal Medicine, China Medicine University Hospital, Taichung (Taiwan); Chang, C.P. [Division of Allergy, Immunology and Rheumatology, Changhua Christian Hospital, Changhua (Taiwan); Wang, J.J. [Department of Medical Research, Chi-Mei Medical Center, Tainan (Taiwan)

    2004-07-01

    Methylprednisolone pulse therapy (MPT) was introduced to avoid life-threatening complications in patients with systemic lupus erythematosus (SLE) with brain manifestations; however, the efficacy of MPT in SLE patients with brain involvement is still uncertain and needs to be objectively evaluated. We enrolled 15 female SLE patients with neuropsychiatric manifestations in this study. All patients had normal brain MRI and abnormal brain HMPAO-SPECT findings. Follow-up HMPAO-SPECT studies were conducted 2 weeks after MPT. Serum levels of anticardiolipin antibodies (ACA) and anti-ribosomal P antibodies (anti-P) were measured before and after MPT. Before MPT, 7 patients were positive for ACA and 7 patients were positive for anti-P. After MPT, none of the 15 patients demonstrated positive serologic findings or neuropsychiatric manifestations. Based on the follow up brain HMPAO-SPECT images following MPT, 13 patients showed disappearance of the perfusion defects and 2 patients showed partial recovery of rCBF. Brain HMPAO-SPECT imaging is a logical and objective tool for measuring the effects of MPT in SLE patients with brain involvement by determining of changes in rCBF. (orig.)

  9. Computer-assisted superimposition of magnetic resonance and high-resolution technetium-99m-HMPAO and thallium-201 SPECT images of the brain

    International Nuclear Information System (INIS)

    Holman, B.L.; Zimmerman, R.E.; Johnson, K.A.; Carvalho, P.A.; Schwartz, R.B.; Loeffler, J.S.; Alexander, E.; Pelizzari, C.A.; Chen, G.T.

    1991-01-01

    A method for registering three-dimensional CT, MR, and PET data sets that require no special patient immobilization or other precise positioning measures was adapted to high-resolution SPECT and MRI and was applied in 14 subjects [five normal volunteers, four patients with dementia (Alzheimer's disease), two patients with recurrent glioblastoma, and three patients with focal lesions (stroke, arachnoid cyst and head trauma)]. T2-weighted axial magnetic resonance images and transaxial 99mTc-HMPAO and 201Tl images acquired with an annular gamma camera were merged using an objective registration (translation, rotation and rescaling) program. In the normal subjects and patients with dementia and focal lesions, focal areas of high uptake corresponded to gray matter structures. Focal lesions observed on MRI corresponded to perfusion defects on SPECT. In the patients who had undergone surgical resection of glioblastoma followed by interstitial brachytherapy, increased 201Tl corresponding to recurrent tumor could be localized from the superimposed images. The method was evaluated by measuring the residuals in all subjects and translational errors due to superimposition of deep structures in the 12 subjects with normal thalamic anatomy and 99mTc-HMPAO uptake. This method for superimposing magnetic resonance and high-resolution SPECT images of the brain is a useful technique for correlating regional function with brain anatomy

  10. Technetium-99mTc-HMPAO brain SPECT in antiphospholipid syndrome - preliminary data

    International Nuclear Information System (INIS)

    Romanowicz, G.; Lass, P.; Koseda-Dragan, M.; Nowicki, R.; Krajka-Lauer, J.

    2000-01-01

    Background: Antiphospholipid syndrome (APS) is defined as the presence of repeated episodes of arterial or venous thrombosis, recurrent spontaneous abortions and throbocytopenia in patients with elevated antiphospholipid antibodies. An important feature of APS are cerebrovascular disorders of thrombotic origin. The aim of the study was to assess cerebral blood flow changes utilising brain SPECT HMPAO scanning. METHODS: Brain SPECT 99mTc-HMPAO scanning was performed in 20 patients with APS: 12 with systemic lupus erythematosus, 4 with Sneddon's syndrome, 2 with Sjoegren's syndrome, 2 with primary APS. 30 healthy volunteers served as a control group. RESULTS: 19 studies were abnormal, 1 normal. Abnormalities consisted of multifocal perfusion deficits and diffuse decrease of regional blood flow. The average number of focal perfusion deficits was 4.8±1.7. In 7 patients diffuse hypoperfusion of frontal lobes was seen, in 1 patient additionally hypoperfusion of temporal and occipital lobes. There was a correlation between the number of focal perfusion deficits and cognitive impairment in this group of patients. Correlation between SPECT images and clinical data was moderate in cerebellar syndrome and paresis, weak in persistent headache and vertigo. CONCLUSIONS: Those results indicate the high utility of CBF brain SPECT scanning in antiphospholipid syndrome. (author)

  11. Discrepant 99mTc-ECD images of CBF in patients with subacute cerebral infarction. A comparison of CBF, CMRO2 and 99mTc-HMPAO imaging

    International Nuclear Information System (INIS)

    Shishido, Fumio; Uemura, Kazuo; Inugami, Atsushi; Ogawa, Toshihide; Fujita, Hideaki; Shimosegawa, Eku; Nagata, Ken.

    1995-01-01

    Three patients with subacute ischemic cerebral infarction examined by SPECT with 99m Tc-ECD and PET within the same day showed signs of luxury perfusion in the subacute phase, which is between 9 to 20 days after the onset. A 99m Tc-HMPAO SPECT study was also performed within 2 days of the ECD-SPECT study. ECD-SPECT images of three patients displayed a focal decreased uptake in the infarcted lesions, while in infarcted foci, there was almost equivalent or increased CBF compared to normal and unaffected areas, decreased CMRO 2 , and high HMPAO uptake. The ECD-SPECT results were similar to those of CMRO 2 rather than CBF, though the HMPAO-SPECT image was similar to that of CBF. In one patient, HMPAO images revealed hyperfixation of the tracer. In the chronic phase and in the acute phase before 5 days after the onset, there were no discrepancies among the ECD-SPECT, CBF, HMPAO-SPECT, and CMRO 2 images. These observations indicated that 99m Tc-ECD is a good indicator of damaged brain tissues in subacute ischemic infarction. They also suggested that 99m Tc-ECD is a potential agent with which to evaluate cerebral tissue viability in some pathological states of cerebrovascular disease. The characteristics may be suitable for confirming the effects of thrombolytic therapy in acute ischemia, because these conditions often show signs of luxury perfusion when the therapy is successful. (author)

  12. Correlation of Tc-99m HMPAO SPECT with surface EEG, MR, and CT for noninvasive localization of seizure foci

    International Nuclear Information System (INIS)

    Engelstad, B.L.; Laxer, K.D.; Dickson, H.S.; Cooper, K.E.; Huberty, J.P.; White, D.L.

    1987-01-01

    Some patients with refractory seizure disorders are candidates for surgical management. Correct preoperative lateralization is essential. Of 19 patients with seizure disorders who underwent Tc-99m HMPAO SPECT, 14 were considered to have ultimately had definitive localization by other means: consistently abnormal surface electroencephalogram (EEG), subdural or deep electrode EEG, EEG response to resection, abnormal histopatholgy, or grossly abnormal MR image. Lateralization with SPECT was (1) focal or regional hypoperfusion (11 patients) or (2) discrete focal hyperperfusion (one patient). Correct lateralization was obtained in ten of 14 with SPECT, nine of 14 with surface EEG, seven of 12 with MR, and one of eight with CT. Preoperative evaluation of patients with medically refractory seizures can be aided by Tc-99m HMPAO SPECT

  13. Technetium-99m-HMPAO labeled leukocyte single photon emission computerized tomography (SPECT) for assessing Crohn's disease extent and intestinal infiltration.

    Science.gov (United States)

    Biancone, L; Schillaci, O; Capoccetti, F; Bozzi, R M; Fina, D; Petruzziello, C; Geremia, A; Simonetti, G; Pallone, F

    2005-02-01

    Scintigraphy using radiolabeled leukocytes is a useful technique for assessing intestinal infiltration in Crohn's disease (CD). However, limits of planar images include overlapping activity in other organs and low specificity. To investigate the usefulness of (99m)Tc-HMPAO (hexametyl propylene amine oxime) labeled leukocyte single photon emission computerized tomography (SPECT) for assessing CD lesions, in comparison with planar images. Twenty-two inflammatory bowel disease patients (19 CD; 2 ulcerative colitis, UC; 1 ileal pouch) assessed by conventional endoscopy or radiology were enrolled. Leukocytes were labeled with (99m)Tc-HMPAO. SPECT images were acquired at 2 h and planar images at 30 min and 2 h. Bowel uptake was quantitated in nine regions (score 0-3). Both SPECT and planar images detected a negative scintigraphy (score 0) in the UC patient with no pouchitis and a positive scintigraphy (score 1-3) in the 21 patients showing active inflammation by conventional techniques. SPECT showed a higher global score than planar images (0.71 +/- 0.09 vs 0.30 +/- 0.05; p < 0.001), and in particular in the right iliac fossa (p= 0.003), right and left flank (p < 0.001; p= 0.02), hypogastrium (p= 0.002), and mesogastrium (p < 0.001). SPECT provided a better visualization and a higher uptake than planar images in patients with ileal and ileocolonic CD (6.45 +/- 0.82 vs 2.8 +/- 0.55, p < 0.001; 5.5 +/- 1.6 vs 2.6 +/- 0.7, p= 0.03), and with perianal CD (6.6 +/- 1.6 vs 3.4 +/- 1.2; p= 0.03). (99m)Tc-HMPAO labeled leukocyte SPECT provides a more detailed visualization of CD lesions than planar images. This technique may better discriminate between intestinal and bone marrow uptake, thus being useful for assessing CD lesions within the pelvis, including perianal disease.

  14. MRI and HMPAO-SPECT in the diagnosis of epilepsy

    International Nuclear Information System (INIS)

    Bokisch, A.; Gruenwald, F.; Elger, C.E.; Kaiser, W.A.; Biersack, H.J.

    1992-01-01

    Eighty-three patients suffering from intractable epilepsy were investigated by magnetic resonance imaging (MRI) and by HMPAO-SPECT during presurgical evaluation. MRI was proven to be most sensitive concerning the detection of focal lesions. Acquisition of thin slices and high signal/noise ratios are prerequisites for optimal sensitivity, the use of Gd-DTPA, in addition, increases the reliability slightly. Histological findings were available in 21 patients and in all cases of focal lesions without prior surgery, malignancy was detected or excluded correctly. The sensitivity was reduced, however, in the 4 patients with recurrency of astrocytoma. 2 cases were missed. Quantitative evaluation of signal intensities in the amygdala/hippocampal region or of the signal dynamics after contrast media application were not helpful in patients without focal lesion. In these patients no reliable criterium to determine the side of the focus with MRI investigations could be established. HMPAO-SPECT investigations were found to be complementary to MRI. In 19 of 36 patients without focal lesions the lateralisation was feasible by scintigraphy. In addition a correlation between the volume asymmetry of the temporal horns detected by MRI and the scintigraphic finding was established. The statistical proven correlation between the unilateral dilatation of the temporal horn and relative hypoperfusion is too weak, however, to imply individual consequences. (orig.) [de

  15. Clinical Utility of '99mTc-HMPAO Brain SPECT Findings in Chronic Head Injury

    International Nuclear Information System (INIS)

    Chung, Jin ll; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Doo; Park, Chang Yoon; Kim, Young Soo

    1992-01-01

    Minima deterioration of cerebral perfusion or microanatomical changes were undetectable on conventional Brain CT or MRI. So evaluation of focal functional changes of the brain parenchyme is essential in chronic head injury patients, who did not show focal anatomical changes on these radiological studies. However, the patients who had longstanding neurologic sequelae following head injury, there had been no available imaging modalities for evaluating these patients precisely. Therefore we tried to detect the focal functional changes on the brain parenchyme using 99m Tc-HMPAO Brain SPECT on the patients of chronic head injuries. Twenty three patients who had suffered from headache, memory dysfunction, personality change and insomnia lasting more than six months following head injury were included in our cases, which showed no anatomical abnormalities on Brain CT or MRI. At first they underwent psychological test whether the symptoms were organic or not. Also we were able to evaluate the cerebral perfusion changes with 99m Tc-HMPAO Brain SPECT in 22 patients among the 23, which five patients were focal and 17 patients were nonfocally diffuse perfusion changes. Thus we can predict the perfusion changes such as local vascular deterioration or functional defects using 99m Tc-HMPAO Brain SPECT in the patients who had suffered from post-traumatic sequelae, which changes were undetectable on Brain CT or MRI.

  16. Comparison of Tc-99m HM-PAO and I-123 IMP cerebral SPECT images in Alzheimer's disease and multi-infarct dementia

    Energy Technology Data Exchange (ETDEWEB)

    Gemmell, H G; Sharp, P F; Besson, J A.O.; Ebmeier, K P; Smith, F W

    1988-10-01

    SPECT images of the brain can be obtained using either /sup 123/I labelled amines or /sup 99m/Tc-hexamethylpropyleneamineoxime (HM-PAO). Both materials produce images which are blood flow dominated and so appear similar in normal subjects, although the respective mechanisms of uptake are not yet finally established. It seems likely, however, that the different mechanisms of uptake are responsible for recent reports of some differences seen in images obtained with the two types of agent in patients with cerebral pathology, mainly cerebrovascular disease. In this study, 12 demented patients, 6 with dementia of the Alzheimer type (DAT) and 6 with multi infarct dementia (MID), were imaged with /sup 123/I-isopropylamphetamine (IMP) and /sup 99m/Tc-HM-PAO and the images compared. Significantly more lesions were seen with IMP than HM-PAO (P < 0.02); out of a possible 120 sites, 41 lesions were seen with IMP compared to 28 with HM-PAO, 23 being seen with both agents. However, it is concluded that either agent can be used for the differential diagnosis of dementia, a task for which the new cerebral blood flow agents seem well suited.

  17. 99mTc-HMPAO SPECT in brain death

    International Nuclear Information System (INIS)

    Tsuchida, Tatsuro; Sadato, Norihiro; Nishizawa, Sadahiko

    1993-01-01

    Brain single photon emission computed tomography (SPECT) with 99m Tc-d,l-hexamethyl-propyleneamine oxime (HMPAO) was performed twice in a 78-year-old man clinically diagnosed as brain death according to the standard criteria of the Japanese Ministry of Welfare. The first brain SPECT demonstrated the tracer accumulation in the brain, indicating preserved cerebral blood flow. The second brain SPECT performed 3 days later revealed cessation of the blood flow. In patients with preserved cerebral blood flow, the diagnosis of brain death cannot be made, even if they meet the existing criteria, because previous report noted the recovery in some of those patients. Brain perfusion SPECT plays an important role as a confirmatory test for the diagnosis of brain death. (author)

  18. Quantitative 123I IMP and 99mTc HMPAO imaging in the dog following cocaine administration

    International Nuclear Information System (INIS)

    Susskind, Herbert; Weber, David A.; Ivanovic, Marija; Wong, Christopher T.C.; Haan, Constance E. de; Gavin, Patrick R.

    1996-01-01

    SPECT and associated imaging procedures were used in beagle dogs to evaluate the uptake, distribution, and clearance properties of i.v.-injected 123 I IMP (IMP) and 99m Tc HMPAO (HMPAO) in the brain, lungs, liver, and kidneys; (2) quantify the acute effects (after 15 sec) of very low doses (0.5 or 1.0 mg/kg) cocaine on the kinetics and localization properties of IMP and HMPAO; and (3) evaluate comparative imaging properties of IMP and HMPAO for measuring regional cerebral blood flow (rCBF). Regional and global uptake and localization of IMP or HMPAO were evaluated in control studies using dynamic planar (0-30 min) and SPECT imaging (at 35 min). The regional distribution properties of IMP and HMPAO in the brain were estimated from regions of interest (ROIs) drawn around anatomic structures on MR slices and manually registered with corresponding SPECT slices. Cocaine significantly reduced the 30-min IMP uptake in the brain and lungs by ∼15%, but only slightly changed HMPAO uptake in the brain and other organs. In the control studies, the respective uptakes of IMP in the brain and lungs were 9 and 39% greater (p < 0.01) than those of HMPAO. In control SPECT studies, the highest uptake of IMP was observed in the thalamus and progressively less activity was observed in the parietal lobe, frontal lobe, cerebellum, occipital lobe, and entire brain; activity in the olfactory bulb was lower than in all other regions. Cocaine reduced IMP uptake in the cerebellum (p < 0.01), occipital lobe (p < 0.01), and entire brain (p < 0.05). IMP uptake (cpm/pixel-mCi) in the different brain regions was 1.3 to 2.1 times greater than that of HMPAO (p < 0.001). HMPAO uptake was more homogeneous throughout the gray matter of the brain; no significant uptake differences were observed among flagged regions. Results indicate that single, acute doses of cocaine, 0.5 and 1.0 mg/kg, significantly altered the uptake and localization properties of IMP in the dog's brain, lungs, liver, and kidneys

  19. Effect of linearization correction on statistical parametric mapping (SPM). A 99mTc-HMPAO brain perfusion SPECT study in mild Alzheimer's disease

    International Nuclear Information System (INIS)

    Ansar, A.B.; Osaki, Yasuhiro; Kazui, Hiroaki

    2006-01-01

    Statistical parametric mapping (SPM) was employed to investigate the regional decline in cerebral blood flow (rCBF) as measured by 99m Tc-hexamethyl propylene amine oxime (HMPAO) single photon emission computed tomography (SPECT) in mild Alzheimer's disease (AD). However, the role of the post reconstruction image processing on the interpretation of SPM, which detects rCBF pattern, has not been precisely studied. We performed 99m Tc-HMPAO SPECT in mild AD patients and analyzed the effect of linearization correction for washout of the tracer on the detectability of abnormal perfusion. Eleven mild AD (National Institute of Neurological and Communicative Disorders and National Institute of Radiological Sciences (NINCDS-ADRDA), male/female, 5/6; mean±SD age, 70.6±6.2 years; mean±SD mini-mental state examination score, 23.9±3.41; clinical dementia rating score, 1) and eleven normal control subjects (male/female, 4/7; mean±SD age, 66.8±8.4 years) were enrolled in this study. 99m Tc-HMPAO SPECT was performed with a four-head rotating gamma camera. We employed linearization uncorrected (LU) and linearization corrected (LC) images for the patients and controls. The pattern of hypoperfusion in mild AD on LU and LC images was detected by SPM99 applying the same image standardization and analytical parameters. A statistical inter image-group analysis (LU vs. LC) was also performed. Clear differences were observed between the interpretation of SPM with LU and LC images. Significant hypoperfusion in mild AD was found on the LU images in the left posterior cingulate gyrus, right precuneus, left hippocampus, left uncus, and left superior temporal gyrus (cluster level, corrected p 99m Tc-HMPAO SPECT with or without linearization correction, which should be carefully evaluated when interpreting the pattern of rCBF changes in mild Alzheimer's disease. (author)

  20. Topodiagnosis in Creutzfeldt-Jakob disease by HMPAO-SPECT

    International Nuclear Information System (INIS)

    Heye, N.; Farahati, J.; Heinz, A.; Buettner, T.; Przuntek, H.; Reiners, C.

    1993-01-01

    A 80-year old female presented with an early stage of Creutzfeldt-Jakob disease with clinical, neurophysiological and neuropathological findings suggesting a focal involvement of the brain. HMPAO SPECT disclosed asymmetries of regional cerebral perfusion, thus suggesting that it may be a further diagnostic instrument in this disease. (orig.) [de

  1. Optimization method for the administered activity to patients in Tc-99-HMPAO cerebral blood flow SPECT in adults

    International Nuclear Information System (INIS)

    Perez Diaz, Marlen; Estevez Aparicio, Eric; Roque Diaz, Reinaldo; Hernandez Rodriguez, Carlos

    2002-01-01

    A method based on the construction of an image quality discriminant function is proposed. The parameters which characterise it are selected among the typical ones measured in a Tc 99m - HMPAO cerebral blood flow SPECT. The results are compared among groups of patient's studies who received different activity (430, 640 and 807 MBq), looking for the minimum that guaranty good image quality. A reduction in the administered 99m Tc-HMPAO activity to the patient down to 430 MBq was possible without affecting the tomographic image quality. The labelling yield was the main parameter that determined the image quality. (author)

  2. Presentation of regional cerebral blood flow in amphetamine abusers by 99Tcm-HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Kao, C.H.; Wang, S.J.; Yeh, S.H.

    1994-01-01

    The aim of this study was to describe the effectiveness of 99 Tc m -hexamethylpropyleneamine oxime ( 99 Tc m -HMPAO) brain single photon emission computed tomography (SPECT) in the assessment of the regional cerebral blood flow (rCBF) in amphetamine abusers. Twenty-one amphetamine abusers were included and 99 Tc m -HMPAO brain SPECT performed to evaluate rCBF. The drug-using periods ranged from 1 month to several years. The demonstrated neuropsychogenic symptoms and signs of the abusers were from normal presentation to various neurologic complications. The brain SPECT scans were interpreted visually as either normal or abnormal. The degree of abnormality was classified into mild or severe. The results revealed that (a) most SPECT studies in abusers show small defects (95%, 20/21 cases); 71% (15/21) of cases revealed multiple defects over both hemispheres (classified as severe); 24% (5/21) of the cases had focal defects (classified as mild); and only one case (5%, 1/21) demonstrated a normal SPECT finding; (b) the degree of abnormality on SPECT scans was not related to the dose and duration of drug use or the severity of the neuropsychiatric symptoms and signs. In conclusion, 99 Tc m -HMPAO brain SPECT is a sensitive but not specific test for neuropsychogenic abnormalities associated with amphetamine abuse. (Author)

  3. Functional and morphological findings in early and advanced stages of HIV infection: A comparison of 99mTc-HMPAO SPECT with CT and MRI studies

    International Nuclear Information System (INIS)

    Tatsch, K.; Bauer, W.M.; Markl, A.; Kirsch, C.M.; Schielke, E.; Einhaeupl, K.M.

    1990-01-01

    In fourty patients at early and advanced stages of HIV infection (Water-Reed stages I-VI) regional cerebral blood flow was determined by 99m Tc-HMPAO SPECT, comparing the results with CT and MRI findings. All patients with HIV encephalopathy (AIDS dementia complex) had pathologic SPECT results (multilocular, patchy uptake defects), but also in earlier and even earliest stages of HIV infection positive SPECT findings were observed. Compared to functional SPECT imaging, morphologically orientated method (CT, MRI) were insensitive in detecting HIV-induced foci: More than 50% of the patients with pathologic SPECT findings had negative CT or MRI scans. Most patients in advanced Walter Reed stages had neurological abnormalities accompanied by positive SPECT. Subtle alterations of HMPAO uptake were observed even in a few cases of early HIV infection without neurological CNS symptoms. The data presented suggest that HMPAO SPECT is highly sensitive in the detection of altered brain perfusion not only in advanced but also early stages of HIV infection. Changes in regional cerebral blood flow are presented before noticeable structural defects may be observed. (orig./MG) [de

  4. Technetium-99m-HMPAO SPECT, CT and MRI in the evaluation of patients with chronic traumatic brain injury: a correlation with neuropsychological performance.

    Science.gov (United States)

    Ichise, M; Chung, D G; Wang, P; Wortzman, G; Gray, B G; Franks, W

    1994-02-01

    The purposes of this study were: (1) to compare 99mTc-hexamethylpropyleneamineoxime (HMPAO) SPECT with CT and MRI in chronic traumatic brain injury (TBI) patients and (2) to correlate both functional and structural neuroimaging measurements of brain damage with neuropsychological (NP) performance. Twenty-nine patients (minor TBI, n = 15 and major TBI, n = 14) and 17 normal controls (NC) underwent HMPAO SPECT, CT, MRI and NP testing. Imaging data were analyzed both visually and quantitatively. Nineteen (66%) patients showed 42 abnormalities on SPECT images, whereas 13 (45%) and 10 (34%) patients showed 29 abnormalities on MRI and 24 abnormalities on CT. SPECT detected relatively more abnormalities than CT or MRI in the minor TBI subgroup. The TBI group showed impairment on 11 tests for memory, attention and executive function. Of these, the anterior-posterior ratio (APR) correlated with six tests, whereas the ventricle-to-brain ratio (VBR), a known structural index of a poor NP outcome, correlated with only two tests. In evaluating chronic TBI patients, HMPAO SPECT, as a complement to CT or MRI, may play a useful role by demonstrating brain dysfunction in morphologically intact brain regions and providing objective evidence for some of the impaired NP performance.

  5. Usefulness of change ratio map in 99mTc-HMPAO SPECT with acetazolamide enhancement

    International Nuclear Information System (INIS)

    Yamamoto, Naoyuki

    1996-01-01

    Although a sequential 99m Tc-HMPAO SPECT technique with Diamox test (seq-SPECT) is a simple and time-saving procedure to assess brain perfusion reserve, the influence of the first dose of the tracer on the second one is not negligible. Therefore, a subtraction of the rest-SPECT from the 2nd SPECT is widely-used. However, subtracted SPECT images not only need to be corrected for the injected dose and the radiochemical purity due to inherent instability of HMPAO but also are usually degraded in quality. This study was undertaken to resolve these problems utilizing a change ratio (CR) map. The CR map was obtained by dividing 2nd SPECT by rest-SPECT. Prior to subtraction, the 2nd SPECT was normalized with the ratio of the mean whole brain counts between both SPECTs. To validate CR map, 7 patients were studied with both seq-SPECT and 133 Xe inhalation CBF measurement (Xe-CBF). The right to left count ratio obtained from the ROIs placed on MCA territory of CR map correlated well with that from Xe-CBF (r=0.89, p<0.01). Fifty-three patients with stroke underwent the seq-SPECT which was compared with the cerebral angiography (CAG) and classified into 4 groups according to the CR map. In 25 patients, all of the rest-, the subtracted-SPECT and the CR map did not show any difference between the affected side and the contralateral normal side. Seven patients with normal rest-SPECT showed decreased subtracted-SPECT counts and CR on the affected side. Three of them showed more than 75% stenosis on CAG. Four patients with the decreased counts both at the rest-and the subtracted-SPECT revealed no difference on the CR map suggesting the matched decrease of both blood flow and metabolism in the affected side. In conclusion, the CR map was a simple and useful method to evaluate the brain perfusion reserve with the seq-SPECT. (author)

  6. Analysis of simulataneous I-123-IPT/Tc-99m-HMPAO dual isotope brain SPECT in Parkinson's disease and normal volunteers using SPM

    International Nuclear Information System (INIS)

    Chung, Y. A.; Juh, R. H.; Kim, S. H.; Park, Y. H.; Lee, S. Y.; Sohn, H. S.; Chung, S. K.

    2002-01-01

    The basal ganglia are usually poorly delineated in Parkinson's diseases on IPT images. We have studied simultaneous dual isotope brain SPECTs using I-123-IPT and Tc-99m-HMPAO, in order to overcome this limitation of IPT imaging. 17 patients (M: 7, F: 10) with Parkinson's disease (Idiopathic parkison's disease: 12, Multiple system atrophy: 5) and 4 normal volunteers (N) underwent the dual isotope brain SPECT following simultaneously injection of 370 MBq Tc-99m-HMPAO (energy window: 130-146 keV) and 111 MBq I-123-IPT (energy window: 152-168 keV). We first obtained parameters of spatial normalization during spatial normalization of Tc-99m-HMPAO brain SPECT using SPECT template. Using these parameters, we could spatially normalized I-123-IPT brain PSECT to standard space, because these images were obtained simultaneously. The difference between each groups(N vs IPD, N vs MSA, IPD vs MSA) were compared with t-test (p<0.01). We demonstrated decreased perfusion in the head and body caudate and globus pallidus on MSA compared with IPD. No significant hypo- and hyperperfusion area was observed in the other analysis. The method proposed in this study can effectively evaluate the dopamine function, and is easily applicable to conventional gamma camera system with any dual energy window acquisition modes

  7. Preliminary results of SPECT studies with 99mTc-HMPAO in endogenous psychoses

    International Nuclear Information System (INIS)

    Wilhelm, K.R.; Georgi, P.; Schroeder, J.; Henningsen, H.; Sauer, H.

    1989-01-01

    18 psychopharmacologically treated patients (7 schizophrenics, 5 schizoaffectives, 6 depressives) were studied using 99m Tc-HMPAO-SPECT of the brain. The regional cerebral blood flow was measured in three transversal sections (infra-/supraventricular, ventricular) within 6 regions of interest (ROI) respectively (one frontal, one parietal and one occipital in each hemisphere). Corresponding ROIs of the same section in each hemisphere were compared. In the schizophrenics there was a significantly reduced perfusion in the left frontal region of the infraventricular and ventricular section (p 99m Tc-HMPAO-SPECT may be helpful in finding cerebral abnormalities in endogenous psychoses. (orig.) [de

  8. Tc-99m-HMPAO neuroactivation SPECT in patients with Alzheimer's disease

    International Nuclear Information System (INIS)

    Klissarova, A.; Tranulov, G.; Deleva, D.; Kaprelyan, A.; Tjaneva, M.

    2002-01-01

    Aim: Tc-99m-HMPAO-SPECT detects the hypoperfusion areas in the temporal and parietal lobes as well as in the frontal lobes in the advanced stages of Alzheimer's disease. These hypoperfusion areas correlate with decreased glucose metabolism and oxygen utilization. The aim of the study was to establish the neuroactivation effect on the regional cerebral blood flow and on the hypoperfusion areas detected by means of Tc-99m-HMPAO-SPECT in patients with Alzheimer's disease. Materials and methods: Subject to the study were 22 patients with Alzheimer's disease divided into two groups according to the results from the neuropsychological tests as follows: Ist group - 10 patients with slight cognitive disturbances; IInd group - 12 patients with prominent cognitive impairment. All patients underwent Brain-SPECT after I.V. injection of 740 MBq Tc-99m-HMPAO at rest and during neuroactivation by labyrinth task on the next day. Regional blood flow was detected by means of the hypoperfusion indices calculated as follows: hypoperfusion areas in the temporal lobe and /or the parietal lobe to the referent areas of the cerebellum. The regional blood flow decrease in hypoperfusion areas was calculated in per cent. Results: Hypoperfusion areas were detected at rest in 5 patients from the Ist group and in all patients from the IInd group. A decrease of the regional cerebral blood flow by 5-10% was established after neuroactivation in all the seventeen patients with hypoperfusion areas at rest. After neuroactivation three of the patients with normal regional cerebral perfusion at rest revealed hypoperfusion areas in the posterior part of the parietal lobe and the temporo-parietal areas. The remaining two patients showed normal regional cerebral blood flow at rest and during neuroactivation. Conclusion: Neuroactivation reduces the regional cerebral blood flow in hypoperfusion areas at rest in patients with Alzheimer's disease. Neuroactivation Tc-99m-HMPAO SPECT is useful for the detection

  9. Differences of Tc-99m HMPAO SPECT imaging in the early stage of subcortical vascular dementia compared with Alzheimer's disease

    International Nuclear Information System (INIS)

    Park, Kyung Won; Kang, Do Young; Park, Min Jeong; Cheon, Sang Myung; Cha, Jae Kwan; Kim, Sang Ho; Kim, Jae Woo

    2007-01-01

    The aim of this study is to assess the specific patterns of regional cerebral blood flow (rCBF) in patients with the early stage of subcortical vascular dementia (SVaD) and Alzheimer's disease (AD) using Tc-99m HMPAO SPECT, and to compare the differences between the two conditions. Sixteen SVaD, 46 AD and 12 control subjects participated in this study. We included the patients with SVaD and AD according to NINCDS-ADRDA and NINDS-AIREN criteria. They were all matched for age, education and clinical dementia rating scores. Three groups were evaluated by Tc-99m HMPAO SPECT using statistical parametric mapping (SPM) for measuring rCBF. The SPECT data of patients with SVaD and AD were compared with those of normal control subjects and then compared with each other. SPM analysis of the SPECT image showed significant perfusion deficits on the right temporal region and thalamus, left insula and superior temporal gyrus, both cingulate gyri and frontal subgyri in patients with SVaD and on the left supramarginal gyrus, superior temporal gyrus, postcentral gyrus and inferior parietal lobule, right fugiform gyrus and both cingulate gyri in AD compared with control subjects (uncorrected ρ < 0.01). SVaD patients revealed significant hypoperfusion in the right parahippocampal gyrus with cingulated gyrus, left insula and both frontal subgyral regions compared with AD (uncorrected ρ < 0.01). Our study shows characteristic and different pattern of perfusion deficits in patients with SVaD and AD, and these results may be helpful to discriminate the two conditions in the early stage of illness

  10. Technetium-labeled HM-PAO studies in patients with cerebrovascular disease

    International Nuclear Information System (INIS)

    Smith, F.W.; Sharp, P.F.; Gemmell, H.; Evans, N.T.; MacDonald, A.F.

    1986-01-01

    Technetium-labeled hexamethyl-propyleneamineoxime (HM-PAO) is a promising radiopharmaceutical for the demonstration of cerebral blood flow. Twenty-four patients who had experienced either acute stroke (AS) or transient ischemic attack (TIA) were studied by x-ray CT and SPECT using technetium-labeled HM-PAO total of 26 studies. HM-PAO has a cerebral distribution similar to that of iodoamphetamine, but labeling with technetium allows good SPECT imaging on demand in any nuclear medicine department. In ten of the 16 patients who had experienced AS, findings on HM-PAO and CT studies correlated well. In six patients reduced cortical perfusion was detected on HM-PAO imaging, but only small infarcts in the internal capsule were seen on CT. In four of the eight patients who had experienced TIA, neither study revealed any abnormality. In the remaining four, areas of cortical underperfusion were seen on HM-PAO imaging, whereas the CT examination was normal. The findings in this study suggest that HM-PAO imaging is a more sensitive method for demonstrating the extent of cerebral underperfusion in cases of cerebrovascular accident

  11. A comparative study of perfusion CT and 99mTc-Hmpao spect measurement to assess cerebrovascular reserve capacity in patients with internal carotid artery occlusion

    Directory of Open Access Journals (Sweden)

    Eicker S

    2011-11-01

    Full Text Available Abstract Background and purpose Patients with internal carotid artery (ICA occlusion can demonstrate impaired cerebral vascular reserve (CVR. The detection of CVR using single photon emission CT (SPECT is nowadays widely accepted as a predictor in the diagnostic pathway in patients considered for cerebral revascularization. Recently perfusion CT (PCT gained widely acceptance in stroke imaging The present study was aimed at comparing the results of perfusion CT (PCT and 99mTc-HMPAO SPECT with acetazolamide challenge in patients with ICA occlusion. Methods 13 patients were included in the prospective evaluation. Both PCT and 99mTc-HMPAO SPECT were performed before and after the administration of acetazolamide. In detail, regional cerebral blood flow (rCBF, regional cerebral blood volume (rCBV, adapted time to peak (Tmax and mean transit times (MTT were compared with SPECT data. Results 99mTc-HMPAO SPECT demonstrated an impairment of CVR in six patients. A preserved CVR was present in seven patients. All patients with impaired CVR proven by SPECT had a delayed MTT (mean +2.98 s and a delayed Tmax (mean + 5.9 s, (both p Conclusion The prospective study demonstrated a highly significant correlation of perfusion parameters as' detected by 99mTc-HMPAO SPECT and the Tmax as detected by PCT in patients with ICA occlusion. Therefore this easy-to-perform technique seems to be an adequate method for the evaluation of cerebral perfusion in patients with ICA occlusion.

  12. Clinical Utility of '9{sup 9m}Tc-HMPAO Brain SPECT Findings in Chronic Head Injury

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jin ll; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Lee, Jong Doo; Park, Chang Yoon; Kim, Young Soo [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1992-03-15

    Minima deterioration of cerebral perfusion or microanatomical changes were undetectable on conventional Brain CT or MRI. So evaluation of focal functional changes of the brain parenchyme is essential in chronic head injury patients, who did not show focal anatomical changes on these radiological studies. However, the patients who had longstanding neurologic sequelae following head injury, there had been no available imaging modalities for evaluating these patients precisely. Therefore we tried to detect the focal functional changes on the brain parenchyme using {sup 99m}Tc-HMPAO Brain SPECT on the patients of chronic head injuries. Twenty three patients who had suffered from headache, memory dysfunction, personality change and insomnia lasting more than six months following head injury were included in our cases, which showed no anatomical abnormalities on Brain CT or MRI. At first they underwent psychological test whether the symptoms were organic or not. Also we were able to evaluate the cerebral perfusion changes with {sup 99m}Tc-HMPAO Brain SPECT in 22 patients among the 23, which five patients were focal and 17 patients were nonfocally diffuse perfusion changes. Thus we can predict the perfusion changes such as local vascular deterioration or functional defects using {sup 99m}Tc-HMPAO Brain SPECT in the patients who had suffered from post-traumatic sequelae, which changes were undetectable on Brain CT or MRI.

  13. Usefulness of {sup 99m}Tc-HMPAO SPECT in Patients with Subarachnoid Hemorrhage due to Ruptured Intracranial Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, C. W.; Lee, K. H.; Kim, J. H.; Kwark, C. E.; Lee, D. S.; Chung, J. K.; Lee, M. C.; Han, D. H.; Koh, C. S. [Seoul National University Hospital, Seoul (Korea, Republic of)

    1993-07-15

    We evaluated the usefulness of {sup 99m}Tc-HMPAO SPECT in 21 Patients with subarachnoid hemorrhage due to ruptured intracranial aneurysm and in 3 patients with unruptured intracranial aneurysm. SPECT study could detect the bilaterally hypoperfused cases in 10 patients(48%), but CT/MRI showed the bilateral abnormalities in only 3 patients(14%). The number of abnormal lesions were 56 in SPECT and 25 in CT/MRI. The lesions found in SPECT were well correlated with the neurological signs of the patients such as aphasia or hemiplegia. SPECT study during Matas test was helpful in evaluating the risk for carotid artery occlusion therapy. We thought that {sup 99m}Tc-HMPAO brain SPECT is helpful in evaluating the functional changes in patients with subarachnoid hemorrhage.

  14. Pre and post operative evaluation of the perfusion reserve by acetazolamide 99mTc-HMPAO SPECT in patients with chronic occlusive cerebral arteries. A comparative study with PET

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Sasaki, Masayuki; Akashi, Yuko; Yoshida, Tsuyoshi; Fukumura, Toshimitsu; Masuda, Kouji; Fujii, Kiyotaka; Fukui, Masashi

    1994-01-01

    We studied the pre and post-operative perfusion reserve using Diamox 99m Tc-HMPAO SPECT in 7 patients with chronic occlusive cerebral arteries and then compared the results with PET. STAMCA anastomosis was performed on 5 patients, while a carotid endarterectomy was done on 2 patients. The cerebral blood flow, the vascular response to CO 2 or Diamox, the oxygen extraction fraction and transit time (CBV/CBF) were measured by PET. In the pre-operative state, the visual evaluations for hypoperfusion area at rest agreed in 5 out of 7 patients in HMPAO SPECT and PET studies. In the remaining 2 patients, hypoperfusion areas were only detected in the PET study. The pre-operative evaluation of perfusion reserve agreed in 2 patients. In the remaining 5 patients, 3 patients showed definite positive (++) in PET and positive (+) in HMPAO SPECT, and one patient showed positive (+) in PET and negative (-) in HMPAO SPECT. The post-operative change of hypoperfusion areas well agreed in HMPAO SPECT and PET studies. However, the change of perfusion reserve was underestimated in HMPAO SPECT compared with PET. In the semiquantitative and quantitative analyses, the count rate ratios (affected/unaffected side) in HMPAO SPECT were apparently higher than those of CBF in PET. The postoperative change of the count rate ratios in HMPAO SPECT were smaller than those of CBF in PET. There was no significant correlation between the change in the ratio of the HMPAO SPECT after the administration of Diamox and the oxygen extraction fraction, and it was thus thought to be impossible to predict the areas with an increased oxygen extraction fraction. Thus, Diamox HMPAO SPECT may underestimate the areas of hypoperfusion or decrease in perfusion reserve when compared with PET. We should consider these limitations in the evaluation of pre and post operative cerebral hemodynamics. (author)

  15. Diagnosis of ischemic cerebrovascular diseases with 99mTc-HMPAO brain SPECT using upright stress test

    International Nuclear Information System (INIS)

    Chen Shaoliang; Xiu Yan; Sun Xiaoguang

    1998-01-01

    Purpose: To evaluate the value of upright brain SPECT stress test, the authors performed 99m Tc-HMPAO brain SPECT in association with measurement of blood pressure in both upright and supine positions. Methods: The authors studied 5 patients with unilateral stenosis occlusion of the internal carotid (Group A), 8 patients with orthostatic hypotension (group B) and 7 normal controls. 370 MBq 99m Tc-HMPAO was injected immediately after uprighting from a supine position. then the first SPECT scan were performed. After the first SPECT, another 555 MBq of 99m Tc-HMPAO were administered while the patients remained on original supine position. Results: Semiquantitive analysis showed that the asymmetric ratios between upright and supine positions in group A changed significantly. In group B, showed postural cerebral hypoperfusion in the bilateral frontal areas, the mean count ratio of the frontal to cerebellar area between the upright and supine positions also significantly changed. In the normal group, there were no significantly changes during the upright test. Conclusions: The upright stress test is useful for detecting not only silent cerebral hypoperfusion, but also orthostatic hypoperfusion

  16. Differences of Tc-99m HMPAO SPECT imaging in the early stage of subcortical vascular dementia compared with Alzheimer's disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Won; Kang, Do Young; Park, Min Jeong; Cheon, Sang Myung; Cha, Jae Kwan; Kim, Sang Ho; Kim, Jae Woo [College of Medicine, Dong-A University, Busan (Korea, Republic of)

    2007-12-15

    The aim of this study is to assess the specific patterns of regional cerebral blood flow (rCBF) in patients with the early stage of subcortical vascular dementia (SVaD) and Alzheimer's disease (AD) using Tc-99m HMPAO SPECT, and to compare the differences between the two conditions. Sixteen SVaD, 46 AD and 12 control subjects participated in this study. We included the patients with SVaD and AD according to NINCDS-ADRDA and NINDS-AIREN criteria. They were all matched for age, education and clinical dementia rating scores. Three groups were evaluated by Tc-99m HMPAO SPECT using statistical parametric mapping (SPM) for measuring rCBF. The SPECT data of patients with SVaD and AD were compared with those of normal control subjects and then compared with each other. SPM analysis of the SPECT image showed significant perfusion deficits on the right temporal region and thalamus, left insula and superior temporal gyrus, both cingulate gyri and frontal subgyri in patients with SVaD and on the left supramarginal gyrus, superior temporal gyrus, postcentral gyrus and inferior parietal lobule, right fugiform gyrus and both cingulate gyri in AD compared with control subjects (uncorrected {rho} < 0.01). SVaD patients revealed significant hypoperfusion in the right parahippocampal gyrus with cingulated gyrus, left insula and both frontal subgyral regions compared with AD (uncorrected {rho} < 0.01). Our study shows characteristic and different pattern of perfusion deficits in patients with SVaD and AD, and these results may be helpful to discriminate the two conditions in the early stage of illness.

  17. Hemodynamic and metabolic state of hyperfixation with 99mTc-HMPAO brain SPECT in subacute stroke

    International Nuclear Information System (INIS)

    Cho, Ihnho; Hayashida, Kohei; Imakita, Satoshi; Kume, Norihiko; Fukuchi, Kazuki

    2000-01-01

    By means of positron emission tomography (PET), we investigated the hemodynamic and metabolic state of the hyperfixation identified as the increased accumulation with 99m Tc-d, l-hexamethylpropyleneamine oxime (HMPAO) by single photon emission computed tomography (SPECT) in patients with subacute stroke. We studied four patients with subacute stroke having hyperfixed areas evaluated with CBF, CMRO 2 , OEF and CBV by PET. The hyperfixation rate with 99m Tc-HMPAO was obtained by comparing the surplus rate with standardized CBF. The OEF and CMRO 2 values in the hyperfixed areas of 4 patients were significantly lower than those in normal 5 controls (p 99m Tc-HMPAO in the infarct area revealing a mismatch between CMRO 2 and CBF meant relative luxury perfusion. The hyperfixation rate determined by 99m Tc-HMPAO brain SPECT correlated with CBV in the PET study. We can conclude that one of the main factors which caused hyperfixation was vasodilatation as well as the blood brain barrier disruption and the neovascularization. (author)

  18. Study of cerebrovascular diseases and SPECT with 99mTc HMPAO

    International Nuclear Information System (INIS)

    Collazo de la Maza, A.; Borron Molinos, M.; Barroso, E.

    1997-01-01

    Thirty eight patients with Cerebrovascular disease, that had suffered a Thrombotic brain infraction, demonstrated by Computed electroencephalogram or Brain Mapping (BM) and Computerized Tomography (CT) were investigated with '99' '9' 'm' Tc HM-PAO brain SPECT. Their ages ranged from 37 to 73 years old, 18 males and 20 female. Some of them were followed up with these diagnostic methods. The acquisition and processing of the SPECT studies were donw with a SOPHY DS7 Gamma Camera. The results showed that the global diagnostic sensibility of the SPECT was 79%. The sensibility of SPECT in the Acute stage was 75 %, CT 57% and BM 92%. In Steady stage we found a high positivity of SPECT with 83 %, Ct 66% and BM 66%. In the Recuperation Stage SPECT was 77%, CT 66% and 45%. Some phenomenon like the Luxury Perfusion and Diaschisis were studied and it is possible to found some prognostic relation

  19. Diagnostic performance of Tc-99m HMPAO SPECT for early and late onset Alzheimer's disease. A clinical evaluation of linearization correction

    International Nuclear Information System (INIS)

    Mitsumoto, Tatsuya; Sakaguchi, Yuichi; Morishita, Junji; Sasaki, Masayuki; Ohya, Nobuyoshi; Abe, Koichiro; Ichimiya, Atsushi; Kiyota, Aya

    2009-01-01

    This study examined the influence of linearization correction (LC) on brain perfusion single-photon emission computed tomography (SPECT) for the diagnosis of Alzheimer's disease (AD). The early onset group (<65 years old) consisted of 10 patients with AD, and the late onset group (≥65 years old) of 13 patients with AD. Age-matched controls included seven younger and seven older normal volunteers. Tc-99m hexamethyl propyleneamine oxine (HMPAO) SPECT images were reconstructed with or without LC [LC (+) or LC (-)] and a statistical analysis was performed using a three-dimensional stereotactic surface projection (3D-SSP). In addition, a fully automatic diagnostic system was developed, which calculated the proportion of the number of abnormal pixels in the superior and inferior parietal lobule, as well as in the precuneus and posterior cingulate gyrus. The areas under the receiver-operating characteristic curve (AUCs) of the early onset group for conventional axial SPECT images, SPECT+3D-SSP images and the fully automatic diagnostic system were 0.71, 0.88, and 0.92 in LC (-) and 0.67, 0.85, and 0.91 in LC (+), respectively. The AUCs of the late onset group were 0.50, 0.61, and 0.79 in LC (-) and 0.49, 0.67, and 0.85 in LC (+), respectively. LC on Tc-99m HMPAO SPECT did not significantly influence the diagnostic performance for differentiating between AD and normal controls in either early or late onset AD. Further examination with individuals suffering from very mild dementia is, therefore, expected to elucidate the effect of LC on minimally hypoperfused areas. (author)

  20. Comparison of 99Tcsup(m) complexes (NEP-DADT, ME-NEP-DADT and HMPAO) with 123IAMP for brain SPECT imaging in dogs

    International Nuclear Information System (INIS)

    Bok, B.D.; Scheffel, U.; Goldfarb, H.W.; Burns, H.D.; Lever, S.Z.; Wong, D.F.; Bice, A.; Wagner, H.N. Jr.

    1987-01-01

    In this study we have compared brain uptake and blood clearance of 99 Tcsup(m)-N-ethylpiperi-dinediamino dithiol ( 99 Tcsup(m)-NEP DADT), its 4-methylated derivative ( 99 Tcsup(m)-Me-NEP-DADT) and 99 Tcsup(m)-hexamethyl-propylene-amine-oxime ( 99 Tcsup(m)-HMPAO) with that of N-isopropyl( 123 I)iodoamphetamine ( 123 IAMP) in two dogs. Single photon emission tomography (SPECT) was employed to measure brain accumulation and retention of the four radiopharmaceuticals. Cerebral uptake of the 99 Tcsup(m) complexes was lower than that of 123 IAMP. There was considerable extracerebral activity in the dog's head, especially in the olfactory and snout regions. Because of slow blood clearance, 99 Tcsup(m)-HMPAO showed high uptake in these regions. Brain uptake of 99 Tcsup(m)-HMPAO reached a plateau 5 to 10 min after intravenous injection and remained constant for the entire study period (1 h). 99 Tcsup(m)-NEP-DADT, on the other hand, showed significant clearance from the brain after reaching maximal uptake at 10 to 15 min after injection. However, brain imaging with these agents was possible during the first 20 min. (author)

  1. Cerebral blood flow imaging by I-123 IMP and Tc-99m HM-PAO

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Koichi; Yoshikawa, Kyosan; Minoshima, Satoshi; Imaseki, Keiko; Arimizu, Noboru; Yamaura, Akira; Uematsu, Sadao

    1988-02-01

    SPECT studies with either N-isopropyl-p-(I-123)iodo- amphetamine (I-123 IMP) or Tc-99m hexamethyl propylene amine oxime (Tc-99m HM-PAO) were cuncurrently performed in 12 patients with brain disorders, comprising cerebral infarction (7), cerebral aneurysm (one), intracranial hemorrhage (3), and subdural hematoma (one). Whereas I-123 IMP was taken up gradually into the brain, the uptake of Tc-99m-HM-PAO in the brain reached the peak immediately after the iv injection, with 90% or more remaining constant by 15 min postinjection. On early SPECT images, a high uptake of I-123 IMP was observed in the lung, and the uptake of Tc-99m HM-PAO was observed as well in the soft tissue of cervical region. In all patients except for one, decreased rCBF was observed in the lesions on both I-123 and Tc-99m SPECT scans. Both of the radiopharmaceuticals were analogous in that decreased blood flow corresponded to cerebral lesions. (Namekawa, K).

  2. Serial 99mTc-HMPAO Brain SPECT for Assessing Perfusion Improvement after DEAS in Moyamoya Patients

    International Nuclear Information System (INIS)

    Lee, Kyung Han; Lee, Sang Hyung; Yeo, Jeong Seok; Kwark, Chul Eun; Chung, June Key; Lee, Myoung Chul; Cho, Byoung Kyu; Koh, Chang Soon

    1994-01-01

    Encephalo-duro-arterio-synangiosis (EDAS) is a relatively new surgical procedure for treatment of childhood moyamoya disease. We assessed regional cerebral perfusion in moyamoya patients before (1.3 mo) and after (6.8 mo) EDAS with 99m Tc-HMPAO brain SPECT. A total of 21 EDAS operations in 17 moyamoya patients was included. Preoperative CT or MRI showed cerebral infarction in 14 patients and carotid angiography showed Suzuki grade 1 to V stenosis in 6%, 9%, 62%, 12% and 12% of the hemispheres respectively. Preoperative SPECT showed regional hypoperfusion in all patients, bilateral frontal and temporal loves being the most frequently involved site. 4 X 4 pixel sized ROIs were applied on the frontotemmporal cortex in 3 slice averaged transverse tomographic images. An index of regional perfusion was measured as; PI (%)=average FT activity/average cerebellar activity X 100 Pre-EDAS ipsilateral PI ranged from 23.7 to 98.4% (mean:74.3 ± 17%) and increased significantly after operation (81.4 ± 17%, p 90, 0.5) (p<0.001). The amount of perfusion improvement (PI) showed significant correlation with CI (r-0.42, p=0.04). PI did not, however, correlate with the amount of neovascularization assessed angiographically in 8 patients. Serial HMPAO SPECT is an useful noninvasive study for assessing perfusion improvement after EDAS in childhood moyamoya patients.

  3. Analysis of Regional Cerebral Blood Flow Using 99mTc-HMPAO Brain SPECT in Senile Dementia of Alzheimer Type

    International Nuclear Information System (INIS)

    Lee, Myung Hae; Lee, Myung Chul; Koh, Chang Soon; Roh, Jae Kyu; Woo, Chong In

    1988-01-01

    99m Tc-HMPAO brain SPECT studies were performed in 11 patients with Alzheimer's disease, 7 patients with psychological depression and 12 normal controls. Changes of regional cerebral blood flow was semiquantitatively analyzed and the results were as follows. 1) In 11 patients with Alzheimer's disease, significant reduction of regional cerebral blood flow was found In both temporoparietal areas. 2) Relative perfusion between cerebral hemispheres was rather symmetrical in patient with Alzheimer's disease. 3) All patients with depression showed normal SPECT findings. As for conclusion, 99m Tc-HMPAO brain SPECT seemed to be a valuable method for clinical assessment and management of patients with Alzheimer's disease.

  4. A Case of Habitual Neck Compression Induced Electroencephalogram Abnormalities: Differentiating from Epileptic Seizures Using a Tc-99m HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hongyoon; Seo, Minseok; Lee, Hoyoung; Kim, Youngsoo; Yun, Changho; Kim, Sangeun; Park, Sungho [Seoul National Univ. Bundang Hospital, Seongnam (Korea, Republic of)

    2014-06-15

    Self-induced hypoxia has been reported particularly in adolescents, and it can result in neurological injury. Here, we present a case of electroencephalogram (EEG) abnormalities induced by habitual neck compression differentiated from epileptic seizures by Tc-99m HMPAO SPECT. A 19-year-old male was admitted for evaluation of recurrent generalized tonic-clonic seizures. No interictal EEG abnormality was detected; however, abnormal slow delta waves were found immediately after habitual right neck compression. To differentiate EEG abnormalities due to a hemodynamic deficit induced by habitual neck compression from an epileptic seizure, Tc-99m HMPAO SPECT was performed immediately after right carotid artery compression. Abnormal delta waves were triggered, and cerebral hypoperfusion in the right internal carotid artery territory was detected on Tc-99m HMPAO SPECT. The slow delta wave detected on the EEG resulted from the cerebral hypoperfusion because of the habitual neck compression.

  5. A Case of Habitual Neck Compression Induced Electroencephalogram Abnormalities: Differentiating from Epileptic Seizures Using a Tc-99m HMPAO SPECT

    International Nuclear Information System (INIS)

    Choi, Hongyoon; Seo, Minseok; Lee, Hoyoung; Kim, Youngsoo; Yun, Changho; Kim, Sangeun; Park, Sungho

    2014-01-01

    Self-induced hypoxia has been reported particularly in adolescents, and it can result in neurological injury. Here, we present a case of electroencephalogram (EEG) abnormalities induced by habitual neck compression differentiated from epileptic seizures by Tc-99m HMPAO SPECT. A 19-year-old male was admitted for evaluation of recurrent generalized tonic-clonic seizures. No interictal EEG abnormality was detected; however, abnormal slow delta waves were found immediately after habitual right neck compression. To differentiate EEG abnormalities due to a hemodynamic deficit induced by habitual neck compression from an epileptic seizure, Tc-99m HMPAO SPECT was performed immediately after right carotid artery compression. Abnormal delta waves were triggered, and cerebral hypoperfusion in the right internal carotid artery territory was detected on Tc-99m HMPAO SPECT. The slow delta wave detected on the EEG resulted from the cerebral hypoperfusion because of the habitual neck compression

  6. Changes of rCBF 99mTc-HMPAO SPECT in a selected disorders

    International Nuclear Information System (INIS)

    Junik, R.

    2003-01-01

    With single photon emission computer tomography (SPECT) and HMPAO a noninvasive examination of regional cerebral blood flow can be performed (rCBF). The purpose of the SPECT examinations was to define the location and magnitude of blood flow disorder in selected diseases and the assessment of the results as complementary to morphological tests CT and MRI or functional tests, such as EEG. The examinations were carried out in 455 patients: 91 - patients with depression, 29 - congenital hypothyroidism, 66 - migraine, 34 - epilepsy, 6 - Landau-Kleffner syndrome, 20 - Alzheimer disease, 55 - with suspected Alzheimer disease, 105 - cerebral stroke, and 48 - transient cerebral ischemia. The control group comprised of 26 subjects. The SPECT method was used to perform examinations. The images were evaluated based on semiquantitative method. The asymmetry of activity and activity referred to the referential region were measured using symmetrical ROIs localized in hypoperfusion foci. The differences in perfusion in symmetric locations exceeding 10% were considered abnormal. During the depression stage, in patients with depression, a decrease of rCBF occurred. Regression of depression results in an increase of rCBF almost in the entire cerebrum. In patients with depression, SPECT examination is a useful method to monitor course of a disease and to objectively verify the results of treatment. 2. Disorders of rCBF, a decrease and/or asymmetry, occurred in patients with congenital hypothyroidism, migraine, and epilepsy. 3. There is a relation between patterns of cerebral perfusion in stroke, visible in SPECT image, and an extent and intensity of cerebral ischemia. (author)

  7. Analysis of Regional Cerebral Blood Flow Using {sup 99m}Tc-HMPAO Brain SPECT in Senile Dementia of Alzheimer Type

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Hae; Lee, Myung Chul; Koh, Chang Soon; Roh, Jae Kyu; Woo, Chong In [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1988-03-15

    {sup 99m}Tc-HMPAO brain SPECT studies were performed in 11 patients with Alzheimer's disease, 7 patients with psychological depression and 12 normal controls. Changes of regional cerebral blood flow was semiquantitatively analyzed and the results were as follows. 1) In 11 patients with Alzheimer's disease, significant reduction of regional cerebral blood flow was found In both temporoparietal areas. 2) Relative perfusion between cerebral hemispheres was rather symmetrical in patient with Alzheimer's disease. 3) All patients with depression showed normal SPECT findings. As for conclusion, {sup 99m}Tc-HMPAO brain SPECT seemed to be a valuable method for clinical assessment and management of patients with Alzheimer's disease.

  8. Statistical parametric mapping of Tc-99m HMPAO SPECT cerebral perfusion in the normal elderly

    International Nuclear Information System (INIS)

    Turlakow, A.; Scott, A.M.; Berlangieri, S.U.; Sonkila, C.; Wardill, T.D.; Crowley, K.; Abbott, D.; Egan, G.F.; McKay, W.J.; Hughes, A.

    1998-01-01

    Full text: The clinical value of Tc-99m HMPAO SPECT cerebral blood flow studies in cognitive and neuropsychiatric disorders has been well described. Currently, interpretation of these studies relies on qualitative or semi- quantitative techniques. The aim of our study is to generate statistical measures of regional cerebral perfusion in the normal elderly using statistical parametric mapping (Friston et al, Wellcome Department of Cognitive Neurology, London, UK) in order to facilitate the objective analysis of cerebral blood flow studies in patient groups. A cohort of 20 healthy, elderly volunteers, aged 68 to 81 years, was prospectively selected on the basis of normal physical examination and neuropsychological testing. Subjects with risk factors, or a history of cognitive impairment were excluded from our study group. All volunteers underwent SPECT cerebral blood flow imaging, 30 minutes following the administration of 370 MBq Tc-99m HMPAO, on a Trionix Triad XLT triple-headed scanner (Trionix Research Laboratory Twinsburg, OH) using high resolution, fan-beam collimators resulting in a system resolution of 10 mm full width at half-maximum (FWHM). The SPECT cerebral blood flow studies were analysed using statistical parametric mapping (SPM) software specifically developed for the routine statistical analysis of functional neuroimaging data. The SPECT images were coregistered with each individual's T1-weighted MR volume brain scan and spatially normalized to standardised Talairach space. Using SPM, these data were analyzed for differences in interhemispheric regional cerebral blood flow. Significant asymmetry of cerebral perfusion was detected in the pre-central gyrus at the 95th percentile. In conclusion, the interpretation of cerebral blood flow studies in the elderly should take into account the statistically significant asymmetry in interhemispheric pre-central cortical blood flow. In the future, clinical studies will be compared to statistical data sets in age

  9. Statistical parametric mapping of Tc-99m HMPAO SPECT cerebral perfusion in the normal elderly

    Energy Technology Data Exchange (ETDEWEB)

    Turlakow, A.; Scott, A.M.; Berlangieri, S.U.; Sonkila, C.; Wardill, T.D.; Crowley, K.; Abbott, D.; Egan, G.F.; McKay, W.J.; Hughes, A. [Austin and Repatriation Medical Centre, Heidelberg, VIC (Australia). Departments of Nuclear Medicine and Centre for PET Neurology and Clinical Neuropsychology

    1998-06-01

    Full text: The clinical value of Tc-99m HMPAO SPECT cerebral blood flow studies in cognitive and neuropsychiatric disorders has been well described. Currently, interpretation of these studies relies on qualitative or semi- quantitative techniques. The aim of our study is to generate statistical measures of regional cerebral perfusion in the normal elderly using statistical parametric mapping (Friston et al, Wellcome Department of Cognitive Neurology, London, UK) in order to facilitate the objective analysis of cerebral blood flow studies in patient groups. A cohort of 20 healthy, elderly volunteers, aged 68 to 81 years, was prospectively selected on the basis of normal physical examination and neuropsychological testing. Subjects with risk factors, or a history of cognitive impairment were excluded from our study group. All volunteers underwent SPECT cerebral blood flow imaging, 30 minutes following the administration of 370 MBq Tc-99m HMPAO, on a Trionix Triad XLT triple-headed scanner (Trionix Research Laboratory Twinsburg, OH) using high resolution, fan-beam collimators resulting in a system resolution of 10 mm full width at half-maximum (FWHM). The SPECT cerebral blood flow studies were analysed using statistical parametric mapping (SPM) software specifically developed for the routine statistical analysis of functional neuroimaging data. The SPECT images were coregistered with each individual`s T1-weighted MR volume brain scan and spatially normalized to standardised Talairach space. Using SPM, these data were analyzed for differences in interhemispheric regional cerebral blood flow. Significant asymmetry of cerebral perfusion was detected in the pre-central gyrus at the 95th percentile. In conclusion, the interpretation of cerebral blood flow studies in the elderly should take into account the statistically significant asymmetry in interhemispheric pre-central cortical blood flow. In the future, clinical studies will be compared to statistical data sets in age

  10. A study of acetazolamide-induced changes in cerebral blood flow using {sup 99m}Tc HMPAO SPECT in patients with cerebrovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Asenbaum, S. [Neurological Clinic, Univ. Vienna (Austria); Reinprecht, A. [Neurosurgical Clinic, Univ. Vienna (Austria); Bruecke, T. [Neurological Clinic, Univ. Vienna (Austria); Wenger, S. [Neurological Clinic, Univ. Vienna (Austria); Podreka, I. [Neurological Clinic, Univ. Vienna (Austria); Deecke, L. [Neurological Clinic, Univ. Vienna (Austria)

    1995-01-01

    For semiquantification of SPECT studies we tried to calculate cerebral {sup 99m}Tc-HMPAO uptake related to injected dose and estimated brain volume. The method was applied to SPECT investigations of 27 patients who had a least one ischaemic attack and a confirmed 80-100% stenosis of the corresponding internal carotid artery (ICA). Vascular reactivity was tested by parenteral administration of acetazolamide (AZ). Increase in HMPAO uptake after AZ was evident in both hemispheres, although the increase (AZ effect) was significantly lower in the affected hemisphere (+24% versus +28%). No interhemispheric uptake differences were seen in patients with largely normal SPECT studies, although local asymmetries in HMPAO deposition were visible. Patients with low density lesions on CT and with a well-demarcated lesion in the same location on SPECT revealed interhemispheric uptake differences, with lower uptake on the affected side. This was not due solely to alterations in the lesion, but also to reduced HMPAO uptake and AZ effect in the surrounding area. The AZ effect showed no correlation with angiographic findings, indicating no major haemodynamic influence of the ICA stenosis on cerebral hemisphere perfusion. Calculated cerebral HMPAO uptake changes after AZ administration were in good accordance with absolute cerebral blood flow measurements, and made interindividual comparisons possible. However, as changes in the area around an infarct or local reduction in vascular reserve may not be reproduced adequately by uptake calculations, visual inspection is still necessary. (orig.)

  11. Mismatched uptake of Tc-99m-ECD and Tc-99m-HMPAO in subacute cerebral infarction: Tc-99m-ECD for viability and Tc-99m-HMPAO for flow restoration

    Energy Technology Data Exchange (ETDEWEB)

    Lee, D. S.; Hyun, I. Y.; Kim, S. K. [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)] [and others

    1997-07-01

    Tc-99m-HMPAO reflects tissue perfusion but Tc-99m-ECD uptake is affected by tissue viability in addition to tissue perfusion which the varied state of cellular retention of Tc-99m-ECD reflects. Luxuriously perfused area on Tc-99m-HMPAO SPECT implies that this cortex was already reperfused either spontaneously or after thrombolysis and that accompanied paralysis of vascular reactivity in those zones warms progressive deterioration. We tried to find out if we can use sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT to reveal cortical perfusion and severity and range of risky areas of cerbral cortex despite reperfusion in sub-acute infarction. In 13 patients (M ; F =7 : 6, mean age 57 (range: 26-84)) with cortical (n=12) and basal ganglia infarction (1), we performed sequential Tc-99m-ECD/Tc-99m-HMPAO SPECT at the same position. At first, 555 MBq of Tc-99m-ECD was injected and imaged and then 1110 MBq of Tc-99m-HMPAO was injected again and imaged with the patients in situ, and the first image (Tc-99m-ECD) and the subtracted image (2nd- 1st : Tc-99m-HMPAO) were compared slice by slice. Study was done from 3 days to 31 days (16{+-}9) after ictus. Tc-99m-ECD uptake was always less than or equal to Tc-99m-HMPAO uptake at the lesion in all cases. Luxury perfusion was prominent in four patients. Mismatched uptake was found in 10 patients. Severity of mismatch showed diverse spectrum and was ranged from total middle cerebral artery territory (1 case) to peripheral thin zones around infarction (2 cases). The other 7 showed intermediate amount of tissues with mismatch , i.e., Tc-99m-ECD defects where Tc-99m-HMPAO uptake is in part increased, normal or decreased. Upon discharge, patients having more uptake with Tc-99m-ECD predicted improvement. Patients having mismatched uptake went dichotomous way. In conclusion, Tc-99m-ECD/Tc-99m-HMPAO sequential SPECT is feasible and reveal both tissue perfusion (Tc-99m-HMPAO ) and discrepant Tc-99m-ECD uptake probably reflecting viability in acute

  12. A clustering model proposal for activity optimization vs. image quality. Application in HMPAO-99mTc brain SPECT

    International Nuclear Information System (INIS)

    Perez, M.; Diaz, O.; Estevez, E.; Roque, R.; Hernandez, C.

    2008-01-01

    A method based on clustering analysis and image quality discriminant functions is tested over HMPAO- 99m Tc -SPECT images to optimize image quality vs. administered activity to patient. Signal-to-Noise ratios and Signal-to-Background ratios in each transaxial slice were measured over the images and used as image quality objective indexes. They were employed to develop image quality classification using a model of three clusters (k-mean Cluster Technique). The mathematical classification was compared with the subjective image quality evaluation, following expert observer criterion. Linear image quality discrimination was developed using the results of the cluster classification and taking as independent variables: the characteristics of the patients (sex, age and weight) and the radiopharmaceutical (labelling yield and administered activity). The dependent variables in the discriminant functions were the cluster centroids. The objective of this procedure was assigning a statistical weight to each image quality determinant variable for the optimization purpose. The method was applied in 30 brain SPECT images, acquired under different activities (400 MBq, 600 MBq, 800 MBq and 1000 MBq as reference), with a Sopha gamma camera, mean-resolution - general purpose - parallel-hole collimator, acquisition matrix 128 x 128 pixels and reconstruction following Filter - Back - Projection Algorithm. We looked for the minimum activity that guaranty most of the cases classified into the cluster with the best image quality (optimization criterion). The value of 800 MBq was the optimum obtained after application of the above methodology for the technology used. The labelling yield and the weight of the patients were the main parameters which determined image quality in clusters, as well as the processing digital filter used. The reduction in the effective dose, as a consequence of this procedure implementation, was also analysed. (author)

  13. Quantitative evaluation of regional cerebral blood flow by visual stimulation in 99mTc-HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Juh, R. H.; Suh, T. S.; Chung, Y. A.

    2002-01-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of 99mTc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99mTc- HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50±5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann

  14. Quantitative evaluation of regional cerebral blood flow by visual stimulation in 99mTc- HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Juh, Ra Hyeong; Suh, Tae Suk; Kwark, Chul Eun; Choe, Bo Young; Lee, Hyoung Koo; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo

    2002-01-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of '9 9m Tc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99m Tc-HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map(SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50±5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann

  15. 99mTc-ECD SPECT study in dementia and aphasia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi

    1993-01-01

    We studied clinical significance of 99m Tc-L,L,-ethyl cysteine dimer ( 99m Tc-ECD) SPECT study in dementia and aphasia, and compared it with 99m Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in 99m Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in 99m Tc-HMPAO SPECT. The count rate ratios in 99m Tc-ECD and 99m Tc-HMPAO SPECT were correlated well with each other, and the contrast of the 99m Tc-ECD SPECT image was equivalent or slightly higher as compared with 99m Tc-HMPAO. Therefore, 99m Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author)

  16. A postural `stressed` cerebral HMPAO case study

    Energy Technology Data Exchange (ETDEWEB)

    Williams, R.C.; Jost, G.M.; Bolitho, L.; Grantham, M. [Wangaratta District Hospital, VIC (Australia)

    1998-03-01

    Full text: This case study represents an example of the utility of postural hypoperfusion stressed HMPAO SPECT. An elderly woman of 78 with a long history of giddiness was referred to our laboratory for examination of possible cerebral ischaemia. She had recurrent dizzy episodes, sometimes posture related, over the past few years and had suffered several falls. Cerebral DSA revealed minimal disease. CT scans were reported as normal. Carotid duplex Doppler studies revealed bilateral plaque disease in the carotid bulbs extending to the origins of the ICAs which were not significant stenoses. Postural symptoms were induced by standing the patient up rapidly and HMPAO was administered at the same time. A SPECT scan of the brain was performed. Quantitative analysis showed a left to right decrease of 10.8% in the temporo-occipital area, 5.6% in the temporo-parietal area and 2.5% in the cerebellar and parietal areas. Images revealed moderately reduced tracer concentration in the left half of the cerebellum and the left occipital region extending as far forward as the temporo-parietal region A repeat HMPAO SPECT scan without stress was normal. This would appear to indicate reversible ischaemia in the left posterior region, and is consistent with the reported symptoms. This case illustrates the usefulness of HMPAO in the diagnosis of reversible cerebral ischaemia.

  17. A postural 'stressed' cerebral HMPAO case study

    International Nuclear Information System (INIS)

    Williams, R.C.; Jost, G.M.; Bolitho, L.; Grantham, M.

    1998-01-01

    Full text: This case study represents an example of the utility of postural hypoperfusion stressed HMPAO SPECT. An elderly woman of 78 with a long history of giddiness was referred to our laboratory for examination of possible cerebral ischaemia. She had recurrent dizzy episodes, sometimes posture related, over the past few years and had suffered several falls. Cerebral DSA revealed minimal disease. CT scans were reported as normal. Carotid duplex Doppler studies revealed bilateral plaque disease in the carotid bulbs extending to the origins of the ICAs which were not significant stenoses. Postural symptoms were induced by standing the patient up rapidly and HMPAO was administered at the same time. A SPECT scan of the brain was performed. Quantitative analysis showed a left to right decrease of 10.8% in the temporo-occipital area, 5.6% in the temporo-parietal area and 2.5% in the cerebellar and parietal areas. Images revealed moderately reduced tracer concentration in the left half of the cerebellum and the left occipital region extending as far forward as the temporo-parietal region A repeat HMPAO SPECT scan without stress was normal. This would appear to indicate reversible ischaemia in the left posterior region, and is consistent with the reported symptoms. This case illustrates the usefulness of HMPAO in the diagnosis of reversible cerebral ischaemia

  18. HMPAO-SPECT in dementia of the Alzheimer type and major depression with memory impairment. HMPAO-SPECT bei Demenz vom Alzheimer-Typ und Major Depression mit mnestischen Stoerungen

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, F [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Horn, R [Bonn Univ., Psychiatrische Klinik (Germany); Rieker, O [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Klemm, E [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Menzel, C [Bonn Univ., Klinik fuer Nuklearmedizin (Germany); Moeller, H J [Bonn Univ., Psychiatrische Klinik (Germany); Biersack, H J [Bonn Univ., Klinik fuer Nuklearmedizin (Germany)

    1993-06-01

    The aim of the present study was to see whether HMPAO-SPECT may contribute to the differentiation between dementia of the Alzheimer type (DAT) and major depression (MD). The results in 77 patients with memory impairment were evaluated. 48 patients suffered from DAT and 29 from MD. Initially, the defects in SPECT imaging were attributed to a cerebral region and the degree of decrease was evaluated (-1/-2/-3). Thereafter, the results were classified by 7 categories. In some of these categories an accumulation of cases of either DAT or MD was found. 35% of the patients suffering from DAT had bilateral defects with distinct (>-1) parietal/parietotemporal hypoperfusions, but no patient with MD showed this perfusion pattern. 62% of the patients with MD had unilateral defects but only 31% of the patients with DAT. The present study demonstrates that only 35% of all patients suffering from DAT show a perfusion pattern, thought earlier as ''pathognomonic'' for this disease. This perfusion pattern - if it exists - may be used as a safe criterion to exclude MD. Beyond that no clearcut (''specific'') perfusion pattern may be recognized but unilateral defects point to MD. (orig.)

  19. Brain Perfusion SPECT Imaging in Sturge - Weber Syndrome : Comparison with MR Imaging

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Choi, Yun Young; Moon, Dae Hyuk; Yang, Seoung Oh; Ko, Tae Sung; Yoo, Shi Joon; Lee, Hee Kyung

    1996-01-01

    The purpose of this study was evaluate the characteristic perfusion changes in patients with Sturge-Weber syndrome by comparison of the findings of brain MR images and perfusion SPECT images. 99m Tc-HMPAO or 99m Tc-ECD interictal brain SPECTs were performed on 5 pediatric patients with Struge-Weber syndrome within 2 weeks after MR imaging. Brain SPECTs of three patients without calcification showed diminished perfusion in the affected area on MR image. A 3 month-old patient without brain atrophy or calcification demonstrated paradoxical hyperperfusion in the affected hemisphere, and follow-up perfusion SPECT revealed decreased perfusion in the same area. The other patient with advanced calcified lesion and atrophy on MR image showed diffusely decreased perfusion in the affected hemisphere, but a focal area of increased perfusion was also noted in the ipsilateral temporal lobe on SPECT. In conclusion, brain perfusion of the affected area of Sturge-Weber syndrome patients was usually diminished, but early or advanced patients may show paradoxical diffuse or focal hyperperfusion in the affected hemisphere. Further studies are needed for better understanding of these perfusion changes and pathophysiology of Struge-Weber syndrome.

  20. Quantitative evaluation of regional cerebral blood flow by visual stimulation in {sup 99m}Tc- HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Juh, Ra Hyeong; Suh, Tae Suk; Kwark, Chul Eun; Choe, Bo Young; Lee, Hyoung Koo; Chung, Yong An; Kim, Sung Hoon; Chung, Soo Kyo [College of Medicine, The Catholic Univ. of Seoul, Seoul (Korea, Republic of)

    2002-06-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of '9{sup 9m}Tc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and {sup 99m}Tc-HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map(SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50{+-}5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

  1. Quantitative evaluation of regional cerebral blood flow by visual stimulation in {sup 99m}Tc-HMPAO brain SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Juh, R. H.; Suh, T. S.; Chung, Y. A. [The Catholic Univ., of Korea, Seoul (Korea, Republic of)

    2002-07-01

    The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of 99mTc-HMPAO (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and 99mTc- HMPAO SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the region of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was 32.50{+-}5.67%. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

  2. Functional brain SPECT with 99mTc-HMPAO in the diagnosis of Alzheimer disease

    International Nuclear Information System (INIS)

    Urbanek, J.; Kupka, K.; Samal, M.; Jirak, R.; Obenberger, J.

    1998-01-01

    The explanatory power of perfusion diagrams obtained by the title technique was examined. In addition to the standard reconstruction procedure, a special reorientation procedure aimed at a differentiation of the hippocampus structure was applied. The study gave evidence of a high specificity and sensitivity of brain SPECT in the differential diagnosis of dementias. Multifactorial analysis of all available diagnostic techniques has borne out the dominant position of brain SPECT with 99m Tc-HMPAO, particularly when using special projection onto the hippocampus, and has led to the formulation of an examination algorithm where a combination of SPECT and MRI (and CT) enables DAT to be distinguished from dementias of other etiologies with a probability higher than 90%

  3. The need of appropriate brain SPECT templates for SPM comparisons

    International Nuclear Information System (INIS)

    Morbelli, S.; Altrinetti, V.; Piccardo, A.; Rodriguez, G.; Brugnolo, A.; Nobili, F.; Mignone, A.; Pupi, A.; Koulibaly, P.M.

    2008-01-01

    Statistical parametric mapping (SPM) is used worldwide to compare brain perfusion single photon emission computed tomography (SPECT) data. The default template within the SPM package used for SPECT image normalization includes images of a group of healthy subjects studied with 99m TcHMPAO. Since [ 99m Tc] HMPAO and [ 99m Tc] ECD have shown to distribute differently in SPECT studies, we formulated the hypothesis that comparing set of [ 99m Tc]ECD data normalized by means of a [ 99m Tc]HMPAO template may lead to incorrect results. A customized [ 99m Tc]ECD template was built with SPECT and magnetic resonance imaging (MRI) images of 22 neurologically healthy women. Then, two sets of subjects, i.e. a group of patients with very early Alzheimer's disease (eAD) and a matched control group, studied by means of [ 99m Tc]ECD SPECT, were chosen for comparisons. The same statistical approach (t-test between eAD patients and controls and correlation analysis between brain SPECT and a cognitive score) was applied twice, i.e. after normalization with either the default [ 99m Tc]HMPAO template or the customized [ 99m Tc]ECD template. In the comparison between eAD and controls, a cluster of difference in the posterior-cingulate gyrus of both hemispheres was only highlighted when using the customized [ 99m Tc]ECD template, but was missed when using the default [ 99m Tc]HMPAO template. In the correlation between brain perfusion and a cognitive score, the significant cluster was more significant and far more extended, also including the right superior temporal gyrus, using the customized [ 99m Tc]ECD template than using the default [ 99m Tc]HMPAO template. These data suggest the need of customized, radiopharmaceutical-matched SPECT templates to be used within the SPM package. The present customized [ 99m Tc]ECD template is now freely available on the web. (authors)

  4. Technetium SPECT agents for imaging heart and brain

    International Nuclear Information System (INIS)

    Linder, K.E.

    1990-01-01

    One major goal of radiopharmaceutical research has been the development of technetium-based perfusion tracers for SPECT imaging of the heart and brain. The recent clinical introduction of the technetium complexes HM-PAO, ECD and DMG-2MP for brain imaging, and of CDO-MEB and MIBI for heart imaging promises to revolutionize the field of nuclear medicine. All of these agents appear to localize in the target tissue in proportion to blood flow, but their mechanisms of localization and/or retention may differ quite widely. In this talk, a survey of the new technetium SPECT agents will be presented. The inorganic and biological chemistry of these complexes, mechanisms of uptake and retention, QSAR studies, and potential clinical applications are discussed

  5. Intrasubject comparison of regional cerebral blood flow between N-isopropyl-p-[123I]iodoamphetamine SPECT and 99mTc-hexamethylpropyleneamine oxime SPECT in patients with ischemic cerebrovascular disease

    International Nuclear Information System (INIS)

    Isaka, Yoshinari; Yoshikawa, Takuya; Ohe, Yohsuke; Nakayama, Hirofumi; Abe, Tohru; Ashida, Keiichi; Imaizumi, Masatoshi; Tanaka, Seiji

    1995-01-01

    Regional cerebral blood flow (CBF) was compared on CBF-SPECT brain images using two perfusion imaging agents, N-isopropyl-p-[ 123 I]iodoamphetamine ( 123 I-IMP) and 99m Tc-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO), in the same patients with ischemic cerebrovascular disease. The subjects were 8 healthy volunteers (group A) and 16 patients with chronic cerebral infarction (group B). SPECT data were normalized to the count density of the tracer in the whole brain, and then converted to the absolute units of CBF by multiplying average 113 Xe-CBF in the whole brain. One-way analysis of variance (ANOVA), grouped by right and left hemispheres in group A and the affected and contralateral hemispheres in group B, was used to assess changes in regional CBF patterns in the two groups. CBF in all regions was significantly reduced on SPECT images, irrespective of the tracers, in group B. F value was higher on IMP images than HMPAO images for the frontal, temporal and occipital cortices, thalamus, and striatum); on the contrary, it was higher on HMPAO images than IMP images for the central lobule, parietal cortex, hippocampus, and centrum semiovale. Two-way ANOVA, grouped by the affected hemisphere in group B, tracer, and affected hemisphere x tracer, indicated that effects of tracer and affected hemisphere x tracer for regional CBF were not significant. For cortical infarction (n=8), regional CBF values in the infarct core were 14.8±4.1 ml/100 g/min on IMP images and 17.6±3.8 ml/100 g/min on HMPAO images; the corresponding figures for the contralateral region were 34.7±8.6 ml/100 g/min and 32.6±8.4 ml/100 g/min. Image contrast was better on IMP images than HMPAO images. In conclusion, an intrasubject comparison in ischemic cerebrovascular disease showed that the detectability of HMPAO CBF-SPECT for CBF abnormalities is roughly equivalent to that of IMP-CBF-SPECT. (N.K.)

  6. Combined study of 99mTc-HMPAO SPECT and computerized electroencephalographic topography (CET) in patients with medically refractory complex partial epilepsy

    International Nuclear Information System (INIS)

    Rodrigues, M.; Botelho, M.M.; Fonseca, A.T.; Peter, J.P.; Pimentel, T.; Vieira, M.R.

    1996-01-01

    For successful surgery for drug-resistant partial epilepsy the site of the seizure focus needs to be known exactly. The purpose of this study was to compare the evaluation of the regional cerebral blood flow (rCBF) (localization and degree of disturbances) by 99m Tc-hexamethylpropylene-amineoxime (HMPAO) single photon emission computed tomography (SPECT) with computerized electroencephalographic topography (CET) and transmission computed X-ray tomography (CT) in partial epilepsy. The study included 20 patients with medically refractory complex partial seizures. Of the 20 patients included, 15 were studied interictally, four ictally and one in both states, interictally and ictally. 99m Tc-HMPAO SPECT detected rCBF changes in 95% of the patients. Interictal studies demonstrated focal areas of hypoperfusion in 93% of the patients. Ictal studies demonstrated an area of hyperperfusion in all patients. Blood flow disturbances in deeper structures of the brain, such as basal ganglia, could be detected. The areas with abnormal 99m Tc-HMPAO uptake were concordant, in localization, with CET in 85% of the patients. Abnormal data with CT scans were found in only 45% of the patients. Focal lesions were found in 20% of the patients by CT scans. 99m Tc-HMPAO SPECT combined with CET may be a useful screening procedure prior to referral for invasive diagnostic procedures in future management of patients with medically refractory complex partial seizures. (author)

  7. [sup 99m]Tc-ECD SPECT study in dementia and aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1993-09-01

    We studied clinical significance of [sup 99m]Tc-L,L,-ethyl cysteine dimer ([sup 99m]Tc-ECD) SPECT study in dementia and aphasia, and compared it with [sup 99m]Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in [sup 99m]Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in [sup 99m]Tc-HMPAO SPECT. The count rate ratios in [sup 99m]Tc-ECD and [sup 99m]Tc-HMPAO SPECT were correlated well with each other, and the contrast of the [sup 99m]Tc-ECD SPECT image was equivalent or slightly higher as compared with [sup 99m]Tc-HMPAO. Therefore, [sup 99m]Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author).

  8. Clinical experience with Tc-99m HM-PAO high resolution SPECT of the brain in patients with cerebrovascular accidents

    International Nuclear Information System (INIS)

    Roo, M. de; Mortelmans, L.; Devos, P.; Verbruggen, A.; Wilms, G.; Carton, H.; Wils, V.; Bergh, R. van den

    1989-01-01

    In order to evaluate the diagnostic contribution of brain SPECT imaging with 99m Tc-HMPAO in cerebrovascular disease, we examined 92 stroke cases (144 lesions), 2 hematoma cases and 30 cases with transient neurologic symptoms. Abnormal tracer distribution is visible as zones of either hypoactivity or hyperactivity (border zone hyperemia or luxury perfusion). Remote vascularization changes could also be found (crossed cerebellar diaschisis or ipsilateral cortical perfusion reduction in thalamic or capsula interna lesions). Both X-ray CT and blood flow SPECT have comparable sensitivity in the exploaration of cerebral infarction, with detection in, respectively, 89,5% and 87,5% of the lesions. False negative scintitomographic images are frequently recorded in small lacunar infarcts within the basal ganglia and white matter (capsula interna). Some early infarcts and asymmetry of brain perfusion in patients with transient neurologic symptoms are frequently not detected by CT. An additional advantage of blood flow SPECT is its ability to visualize remote blood flow changes and the changing pattern of vascularization of ischemic lesions and their surrounding areas including hyperemia. (orig.)

  9. Clinical experience with Tc-99m HM-PAO high resolution SPECT of the brain in patients with cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Roo, M. de; Mortelmans, L.; Devos, P.; Verbruggen, A.; Wilms, G.; Carton, H.; Wils, V.; Bergh, R. van den

    1989-01-01

    In order to evaluate the diagnostic contribution of brain SPECT imaging with /sup 99m/Tc-HMPAO in cerebrovascular disease, we examined 92 stroke cases (144 lesions), 2 hematoma cases and 30 cases with transient neurologic symptoms. Abnormal tracer distribution is visible as zones of either hypoactivity or hyperactivity (border zone hyperemia or luxury perfusion). Remote vascularization changes could also be found (crossed cerebellar diaschisis or ipsilateral cortical perfusion reduction in thalamic or capsula interna lesions). Both X-ray CT and blood flow SPECT have comparable sensitivity in the exploaration of cerebral infarction, with detection in, respectively, 89,5% and 87,5% of the lesions. False negative scintitomographic images are frequently recorded in small lacunar infarcts within the basal ganglia and white matter (capsula interna). Some early infarcts and asymmetry of brain perfusion in patients with transient neurologic symptoms are frequently not detected by CT. An additional advantage of blood flow SPECT is its ability to visualize remote blood flow changes and the changing pattern of vascularization of ischemic lesions and their surrounding areas including hyperemia.

  10. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  11. Increased cerebral blood flow in MELAS shown by Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Peng, N.J.; Tsay, D.G.; Liu, R.S.; Li, J.Y.; Kong, K.W.; Kwok, C.G.; Strauss, H.W.

    2000-01-01

    We report cerebral SPECT studies on two siblings with the syndrome of mitochondrial myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS). Tc-99m HMPAO brain SPECT was performed 8, 19 and 30 days after a stroke-like episode in one case and 10 days after a stroke-like episode, 6 h after a partial seizure and as a follow-up study in the other. Increased blood flow was seen in both these patients with stroke-like episodes due to MELAS. The cause of the increased blood flow is uncertain, but it may be related to the decreased pH created by local increase in lactic acid. (orig.)

  12. Brain SPECT by intraarterial infusion of 99mTc-HMPAO for assessing the cerebral distribution of carotid artery infusions in patient with brain tumor

    International Nuclear Information System (INIS)

    Kosuda, Shigeru; Kusano, Shoichi; Aoki, Shigeki

    1993-01-01

    In order to assess the cerebral distribution of intracarotid chemotherapy, 17 postoperative patients with brain tumor underwent brain SPECT obtrained by intraarterial infusion of 18.5 MBq of 99m Tc-d,l,-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO). Injection methods were continuous (5.0 ml/min) or pulsatile infusion with supra- or infraophthalmic catheterization. The findings obtained by brain SPECT were frequently different from those of angiography and/or DSA. In supraophthalmic catheterization with continuous infusion, only 2 of 10 studies (20%) had homogeneous distribution and 5 of them (50%) had maldistribution of 99m Tc-HMPAO which appears in association with laminar flow effect. The remaining 3 studies showed localized distribution (two: tumor localization, one: healthy brain localization). On the other hand, all of 5 studies with pulsatile infusion had homogeneous distribution of 99m Tc-HMPAO. In infraophthalmic catheterization, all but one of 5 studies had homogeneous distribution with continuous infusion. These results suggest that pulsatile infusion may be effective in eliminating maldistribution of 99m Tc-HMPAO in supraophthalmic catheterization. In conclusion, we are convinced that 99m Tc-HMPAO is a useful intraarterial agent for assessing cerebral distribution of intracarotid chemotherpay. (author)

  13. Comparison of {sup 99m}Tc-HMPAO SPECT and MRI after Acute and Subacute Closed-Head Injury

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Won Jong; Lee, Sang Hoon; Sohn, Hyung Sun; Lee, Han Jin; Park, Jeong Mi; Chung, Soo Kyo; Kim, Choon Yul; Bahk, Yong Whee; Shin, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    The purpose of this study was to compare {sup 99m}Tc-HMPAO SPECT with MRI after acute and subacute closed head injury. There were thirty two focal lesions in all cases of these, Fifteen lesions(47%) were seen on both MRI and SPECT. Fourteen lesions(44%) were seen only on MRI. Three lesions(9%) were seen only on SPECT. Of the 14 lesions seen only on MRl, one was epidural hematoma, two were subdural hematoma, three were subdural hygroma, one was intracerebral hematoma, four were contusion, and three were diffuse axonal injuries. SPECT detected 52% of the focal lesions found on MRI. For the detection of lesions, MRl was superior to SPECT in fourteen cases, while SPECT was superior to MRI in three cases. In conclusion, there was a tendency that detection rate of the traumatic lesions was higher on MRI, but the SPECT could delineate more wide extent of lesion.

  14. Memory functions and rCBF-99mTc-HMPAO-SPECT: Developing diagnostics in Alzheimer's Disease

    International Nuclear Information System (INIS)

    Sundstroem, T.; Riklund Ahlstroem, K.; Elgh, E.; Naesman, B.; Nyberg, L.

    2002-01-01

    Alzheimer's disease (AD) is a primary degenerative disease of the brain. The prevalence increases with age with devastating consequences for the individual and for the society. The aim of this study was to evaluate if patients with early AD show an altered regional cerebral blood flow (rCBF) compared to control persons. The aim was furthermore to investigate the correlation between rCBF in sub-lobar volumes of the brain and performance on memory tests. Memory tests were chosen to evaluate episodic and semantic memory. Fourteen patients (75.2±8.8 yrs) with early AD, and 15 control persons (71.4±3.2 yrs) were included. rCBF measurements with single photon emission computerized tomography (SPECT) using 99m Tc-hexamethyl propylenamine oxime (HMPAO) were performed. The rCBF- 99m Tc-HMPAO-SPECT images were spatially transformed to fit a brain atlas and normalized for differences in rCBF (Computerized Brain Atlas software). Cortical and sub-cortical volumes of interests (VOI) were analyzed and compared. Compared to the controls, AD-patients showed a significantly lower rCBF ratio in temporoparietal regions including left hippocampus. The diagnostic sensitivity and specificity for AD were high in temporoparietal regions. AD-patients had significantly reduced performance on semantic and, in particular, episodic memory tests compared to age matched normative data, and their performance on several episodic tests correlated with rCBF ratios in parietal and temporal regions including left hippocampus. The correlation between rCBF ratio and level of episodic memory performance suggests that abnormalities in rCBF pattern underlie impaired episodic memory functioning in AD

  15. A new prognostic index - leucocyte infiltration - in human cerebral infarcts by 99Tcm-HMPAO-labelled white blood cell brain SPECT

    International Nuclear Information System (INIS)

    Kao, C.H.; Wang, P.Y.; Wang, Y.L.; Chang, L.; Wang, S.J.; Yeh, S.H.

    1991-01-01

    Twenty-six patients with acute cerebral infarction were imaged by 99 Tc m -hexamethylpropylene-amine oxime (HMPAO)-labelled white blood cell brain (Tc-WBC) single photon emission computed tomography (SPECT). The regions of interest were equally placed in the whole hemispheres of both sides with summation of all transaxial slices in the Tc-WBC SPECT. The asymmetric indices (AI) were calculated as 200 [|(right -left)|/(right + left)]. Grouping of patients with cerebral infarction was based on activities of daily living (ADL) at outcome. The results showed that the poor outcome patient group had a higher AI of Tc-WBC than that of the other patients (13.0 ± 3.0 S.E.M. versus 5.4 ± 1.0 S.E.M., and P < 0.05 by Wilcoxon rank sum test). In conclusion, the Tc-WBC SPECT may be considered as a new prognostic index to predict patient outcome in human cerebral ischaemic infarctions consistent with newly established ischaemic injury theories. (author)

  16. Clinical value of scatter correction for interictal brain 99m Tc-HMPAO SPECT in mesial temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Sanchez Catasus, C.; Morales, L.; Aguila, A.

    2002-01-01

    Aim: It is well known that some patients with temporal lobe epilepsy (TLE) show normal perfusion during interictal SPECT study. The aim of this research was to evaluate if the scatter radiation has some influence on this kind of result. Materials and Methods: We studied 15 patients with TLE by clinical diagnosis and by video-EEG monitoring with surface electrodes (11 left TLE, 4 right TLE), which showed normal perfusion during interictal brain 99m Tc-HMPAO SPECT. The SPECT data were reconstructed by filtered backprojection without scatter correction (A). The same SPECT data were reconstructed after the projections were corrected by dual energy window method of scatter correction (B). Attenuation was corrected in all cases using first order Chang Method. For A and B images groups, cerebellum perfusion ratios were calculated on irregular regions of interest (ROI) drawn on anterior (ATL), lateral (LTL), mesial (MTL) and whole temporal lobe (WTL). To evaluate the influence of scatter radiation, the cerebellum perfusion ratios of each subject were compared with a normal database of 10 normal subjects, with and without scatter correction, using z-score analysis. Results: In group A, the z-score was less than 2 in all cases. In group B, the z-score was more than 2 in 6 cases, 4 in MTL (3 left, 1 right) and 2 in left LTL, which were coincident with the EEG localization. All images of group B showed better contrast than images of group A. Conclusions: These results suggest that scatter correction could improve the sensitivity of interictal brain SPECT to identify epileptic focus in patients with TLE

  17. 99mTc-HMPAO-SPECT in the diagnosis of senile dementia of Alzheimer's type - a study under clinical routine conditions

    International Nuclear Information System (INIS)

    Stoppe, G.; Staedt, J.; Schuetze, R.; Kunert, H.J.; Ruether, E.; Koegler, A.; Sandrock, D.; Emrich, D.

    1995-01-01

    This study was designed to evaluate whether investigations of cerebral blood flow can be a helpful diagnostic tool in the differential diagnosis between (senile) dementia of Alzheimer's type [(S)DAT] and geriatric depression with cognitive impairment. Under clinical routine conditions we performed Single Photon Emission Computed Tomography (SPECT) using 99m Tc-Hexamethylpropyleneamine Oxime (HMPAO) in 23 patients with (S)DAT (14 f, 9 m; mean age 68.9 y), 17 patients with geriatric depression (9 f, 8 m; mean age 66.4 y) and 12 age-matched controls (9 f, 3 m; mean age 69.2 y). Semiquantitative analysis (corticocerebellar ratios) of eight different regions of interest (ROI) revealed a significantly ( p 99m Tc-HMPAO SPECT is a valuable additional tool in the differential diagnosis of depression and dementia in the elderly. (author)

  18. HMPAO-SPECT in dementia of the Alzheimer type and major depression with memory impairment

    International Nuclear Information System (INIS)

    Gruenwald, F.; Horn, R.; Rieker, O.; Klemm, E.; Menzel, C.; Moeller, H.J.; Biersack, H.J.

    1993-01-01

    The aim of the present study was to see whether HMPAO-SPECT may contribute to the differentiation between dementia of the Alzheimer type (DAT) and major depression (MD). The results in 77 patients with memory impairment were evaluated. 48 patients suffered from DAT and 29 from MD. Initially, the defects in SPECT imaging were attributed to a cerebral region and the degree of decrease was evaluated (-1/-2/-3). Thereafter, the results were classified by 7 categories. In some of these categories an accumulation of cases of either DAT or MD was found. 35% of the patients suffering from DAT had bilateral defects with distinct (>-1) parietal/parietotemporal hypoperfusions, but no patient with MD showed this perfusion pattern. 62% of the patients with MD had unilateral defects but only 31% of the patients with DAT. The present study demonstrates that only 35% of all patients suffering from DAT show a perfusion pattern, thought earlier as ''pathognomonic'' for this disease. This perfusion pattern - if it exists - may be used as a safe criterion to exclude MD. Beyond that no clearcut (''specific'') perfusion pattern may be recognized but unilateral defects point to MD. (orig.) [de

  19. Multimodality imaging: transfer and fusion of SPECT and MRI data

    International Nuclear Information System (INIS)

    Knesaurek, K.

    1994-01-01

    Image fusion is a technique which offers the best of both worlds. It unites the two basic types of medical images: functional body images(PET or SPECT scans), which provide physiological information, and structural images (CT or MRI), which provide an anatomic map of the body. Control-point based registration technique was developed and used. Tc-99m point sources were used as external markers in SPECT studies while, for MRI and CT imaging only anatomic landmarks were used as a control points. The MRI images were acquired on GE Signa 1.2 system and CT data on a GE 9800 scanner. SPECT studies were performed 1h after intravenous injection of the 740 MBq of the Tc-99m-HMPAO on the triple-headed TRIONIX gamma camera. B-spline and bilinear interpolation were used for the rotation, scaling and translation of the images. In the process of creation of a single composite image, in order to retain information from the individual images, MRI (or CT) image was scaled to one color range and a SPECT image to another. In some situations the MRI image was kept black-and-white while the SPECT image was pasted on top of it in 'opaque' mode. Most errors which propagate through the matching process are due to sample size, imperfection of the acquisition system, noise and interpolations used. Accuracy of the registration was investigated by SPECT-CT study performed on a phantom study. The results has shown that accuracy of the matching process is better, or at worse, equal to 2 mm. (author)

  20. Imaging of mild traumatic brain injury using 57Co and 99mTc HMPAO SPECT as compared to other diagnostic procedures.

    Science.gov (United States)

    Audenaert, Kurt; Jansen, Hugo M L; Otte, Andreas; Peremans, Kathelijne; Vervaet, Myriam; Crombez, Roger; de Ridder, Leo; van Heeringen, Cees; Thirot, Joel; Dierckx, Rudi; Korf, Jaap

    2003-10-01

    Traumatic brain injury (TBI) is usually assessed with the Glasgow Coma Scale (GCS), CT and EEG. TBI can result from either the primary mechanical impact or secondary (ischemic) brain damage, in which calcium (Ca) plays a pivotal role. This study was undertaken to compare the applicability of SPECT using 57Co as a Ca-tracer in patients with mild traumatic brain injury. 8 patients with mild TBI (GCS 15) were clinically examined and studied with EEG, neuropsychological testing (NPT) and SPECT within 2 days post-TBI. After i.v.-administration of 37 MBq (1 mCi) 57Co (effective radiation dose 0.34 mSv x MBq(-1); 1.24 rem x mCi(-1); physical half-life 270 days, biological half-life 37.6 h), single-headed SPECT (12 h pi) was performed, consecutively followed by standard 925 MBq (25 mCi) Tc-99m HMPAO SPECT. In 6 of the 8 patients, baseline NPT and SPECT showed focal abnormalities in the affected frontal and temporal brain regions, which were in good topographical accordance. CT and EEG did not detect (structural) lesions in any of these cases. Single-headed 57Co-SPECT is able to show the site and extent of brain damage in patients with mild TBI, even in the absence of structural lesions. It may confirm and localize NPT findings. The predictive value of 57Co-SPECT should be assessed in larger patient series.

  1. Evaluation of Gilles de la Tourette syndrome with [99mTc] HMPAO Brain SPECT

    International Nuclear Information System (INIS)

    Carreira, LCTF; Santos, A. O; Juarez, B. A; Leite, H. A; Lima, M. C. L; Ramos, C. D; Camargo, E. E

    2002-01-01

    Gilles de la Tourette syndrome (GLTS) is a disorder characterized by tics and several behavioral disturbances. Although GLTS is a relatively common disorder, little is known about its pathophysiology. Previous studies with SPECT and PET were performed in a small number of patients and have shown some discordant data. The aim of this study is to evaluate brain perfusion abnormalities in patients with GLTS and to correlate them with the clinical manifestations of the syndrome. Twenty-eight patients were submitted to brain [99mTc]-HMPAO SPECT. 82 percent of the patients had abnormal studies. The most frequent finding was perfusion abnormalities in the thalami in 16 patients (57 percent) and 85 percent of patients with hyperperfusion of one or both thalami had complex motor tics. This investigation has demonstrated that brain perfusion SPECT is able to identify cortical perfusion abnormalities, associated with clinical symptoms in patients with GLTS. These abnormalities involve the pre-frontal-striatal-thalamic-cortical pathways (Au)

  2. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  3. Pinhole SPECT: high resolution imaging of brain tumours in small laboratory animals

    International Nuclear Information System (INIS)

    Franceschim, M.; Bokulic, T.; Kusic, Z.; Strand, S.E.; Erlandsson, K.

    1994-01-01

    The performance properties of pinhole SPECT and the application of this technology to evaluate radionuclide uptake in brain in small laboratory animals were investigated. System sensitivity and spatial resolution measurements of a rotating scintillation camera system were made for a low energy pinhole collimator equipped with 2.0 mm aperture pinhole insert. Projection data were acquired at 4 degree increments over 360 degrees in the step and shoot mode using a 4.5 cm radius of rotation. Pinhole planar and SPECT imaging were obtained to evaluate regional uptake of Tl-201, Tc-99m-MIBI, Tc-99m-HMPAO and Tc-99m-DTPA in tumor and control regions of the brain in a primary brain tumor model in Fisher 344 rats. Pinhole SPECT images were reconstructed using a modified cone- beam algorithm developed from a two dimensional fan-beam filtered backprojection algorithm. The reconstructed transaxial resolution of 2.8 FWHM and system sensitivity of 0.086 c/s/kBq with the 2.0 mm pinhole collimator aperture were measured. Tumor to non-tumor uptake ratios at 19-28 days post tumor cell inoculation varied by a factor > 20:1 on SPECT images. Pinhole SPECT provides an important new approach for performing high resolution imaging: the resolution properties of pinhole SPECT are superior to those which have been achieved with conventional SPECT or PET imaging technologies. (author)

  4. Decreased cerebral blood flow and prognosis of Alzheimer's disease. A multicenter HMPAO-SPECT study

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hashikawa, Kazuo; Fukuyama, Hidenao

    2007-01-01

    The purpose of this study was to determine the usefulness of brain perfusion single photon emission computed tomography (SPECT) for evaluating the severity and progression of Alzheimer's disease (AD). Eighty-four AD patients were included. At entry, 99m Tc-HMPAO-SPECT, the Mini Mental State Examination (MMSE), Mental Function Impairment Scale (MENFIS), and the Raven Colored Progression Matrix (RCPM) were performed for all 84 patients. During the follow-up periods, two individual MMSE evaluations in 34 patients, two MENFIS evaluations in 30 patients, and two RCPM evaluations in 20 patients were performed. Based on the regions of decreased cerebral blood flow demonstrated on three-dimensional stereotactic surface projection (3D-SSP) images of SPECT, the cases were classified as type A (no decrease), type B (decreased blood flow in the parietal or temporal lobe), type C (decreased blood flow in the frontal lobe and parietal or temporal lobe), type Pc (decreased blood flow in posterior cingulate gyrus only), and ''other types''. The types of decreased blood flow, scores on neuropsychological evaluations, and symptom progression were analyzed. The MENFIS, MMSE, and RCPM scores were poorest in type C patients at entry. The degree of decrease of these scores during the follow-up periods was also greatest in type C. The greatest difference between patients with and without rapid progression in SPECT data of the mild AD patients (MMSE score≥24) was in the frontal lobe. Decreased blood flow in the frontal lobe of AD patients is correlated not only with reduced cognitive function at the time of the evaluation but with rapid progression in the subsequent clinical course. (author)

  5. CBF patterns in different types of headache using 99mTc HMPAO and high resolution SPECT

    International Nuclear Information System (INIS)

    Jones, B.E.; Davies, P.G.; Costa, D.C.; Steiner, T.J.; Rose, F.C.; Jewkes, R.F.; Charing Cross Hospital, London

    1988-01-01

    High resolution SPECT studies have been performed using 99m Tc HMPAO on patients suffering from migraine, cluster headache or chronic tension headache. Reduced uptake of tracer in the right parieto-occipital cortex was seen in 6/8 patients suffering from classical or hemiplegic migraine and 2/10 patients suffering from common migraine. A high uptake of tracer was seen in the temporal muscle of some patients with chronic tension headache. Extracerebral uptake of radioactivity was also seen in the tissue surrounding the brain in a case injected with the HMPAO 45 minutes after it had been prepared and in metastatic skull lesions in patients suffering from cancer of the breast. It is therefore important to use high resolution instrumentation to avoid artifacts when using this technique. (orig.)

  6. Age-related changes in brain perfusion of normal subjects detected by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Krausz, Y.; Karger, H.; Chisin, R.; Bonne, O.; Gorfine, M.; Lerer, B.

    1998-01-01

    Previous functional imaging data generally show impairment in global cerebral blood flow (CBF) with age. Conflicting data, however, concerning age-related changes in regional CBF (rCBF) have been reported. We examined the relative rCBF in a sample of healthy subjects of various ages, to define and localize any age-related CBF reduction. Twenty-seven healthy subjects (17 male, 10 female; mean age 49 ± 15, range 26-71, median 47 years) were studied by 99m Tc-HMPAO brain SPECT. The younger age group consisted of subjects below, the older group above 47 years of age, respectively. Analysis was performed by applying three preformed templates, each containing delineated regions of interest (ROIs), to three transaxial brain slices at approximately 4, 6, and 7 cm above the orbitomeatal line (OML). The average number of counts for each ROI was normalized to mean uptake of the cerebellum and of the whole brain slice. Globally, 99m Tc-HMPAO uptake ratio normalized to cerebellum was significantly decreased in older subjects, affecting both hemispheres. A slight left-to-right asymmetry was observed in HMPAO uptake of the whole study group. It did not, however, change with age. Regionally, both cortical and subcortical structures of older subjects were involved: uptake ratio to cerebellum was significantly lower (after correction for multiple testing) in the left basal ganglia and in the left superior temporal, right frontal and bilateral occipital cortices at 4 cm above the OML. At 6 cm above the OML, reduced uptake ratios were identified in the left frontal and bilateral parietal areas. At 7 cm, reduced uptake was detected in the right frontal and left occipital cortices. Most of these differences were reduced when uptake was normalized to whole slice, whereas an increase in uptake ratios was observed in the cingulate cortex of the elderly. An inverse correlation between age and HMPAO uptake ratios normalized to cerebellum was observed in a number of brain regions. These

  7. Brain perfusion SPECT in the mouse: normal pattern according to gender and age.

    Science.gov (United States)

    Apostolova, Ivayla; Wunder, Andreas; Dirnagl, Ulrich; Michel, Roger; Stemmer, Nina; Lukas, Mathias; Derlin, Thorsten; Gregor-Mamoudou, Betina; Goldschmidt, Jürgen; Brenner, Winfried; Buchert, Ralph

    2012-12-01

    Regional cerebral blood flow (rCBF) is a useful surrogate marker of neuronal activity and a parameter of primary interest in the diagnosis of many diseases. The increasing use of mouse models spawns the demand for in vivo measurement of rCBF in the mouse. Small animal SPECT provides excellent spatial resolution at adequate sensitivity and is therefore a promising tool for imaging the mouse brain. This study evaluates the feasibility of mouse brain perfusion SPECT and assesses the regional pattern of normal Tc-99m-HMPAO uptake and the impact of age and gender. Whole-brain kinetics was compared between Tc-99m-HMPAO and Tc-99m-ECD using rapid dynamic planar scans in 10 mice. Assessment of the regional uptake pattern was restricted to the more suitable tracer, HMPAO. Two HMPAO SPECTs were performed in 18 juvenile mice aged 7.5 ± 1.5weeks, and in the same animals at young adulthood, 19.1 ± 4.0 weeks (nanoSPECT/CTplus, general purpose mouse apertures: 1.2kcps/MBq, 0.7mm FWHM). The 3-D MRI Digital Atlas Database of an adult C57BL/6J mouse brain was used for region-of-interest (ROI) analysis. SPECT images were stereotactically normalized using SPM8 and a custom made, left-right symmetric HMPAO template in atlas space. For testing lateral asymmetry, each SPECT was left-right flipped prior to stereotactical normalization. Flipped and unflipped SPECTs were compared by paired testing. Peak brain uptake was similar for ECD and HMPAO: 1.8 ± 0.2 and 2.1 ± 0.6 %ID (p=0.357). Washout after the peak was much faster for ECD than for HMPAO: 24 ± 7min vs. 4.6 ± 1.7h (p=0.001). The general linear model for repeated measures with gender as an intersubject factor revealed an increase in relative HMPAO uptake with age in the neocortex (p=0.018) and the hippocampus (p=0.012). A decrease was detected in the midbrain (p=0.025). Lateral asymmetry, with HMPAO uptake larger in the left hemisphere, was detected primarily in the neocortex, both at juvenile age (asymmetry index AI=2.7 ± 1

  8. Tc99m-HMPAO Neuro--SPECT Assessment of Ischemic Penumbra in Acute Brain Infarct: Control of Intra-arterial Thrombolysis Treatment

    International Nuclear Information System (INIS)

    Mena, Francisco; Mena, Ismael; Ducci, Hector; Soto, Francisco; Pedraza, Luis; Contreras, Andrea; Miranda, Marcelo; Basaez, Esteban; Fruns, Manuel

    2004-01-01

    Acute brain infarct is a medical emergency potentially reversible if treated with thrombolysis, an approved therapy, if performed in the first 3 to 6 hours of evolution. Thrombolysis has many benefits, but it also has associated risks, mainly development of intracranial hemorrhage. The selection of which patient should receive this type of treatment had been an important research topic over the last decade. As a consequence neuroimaging of brain infarct has significantly improved during the last few years. A variety of diagnostic studies are now available in the evaluation of brain infarct and in particular of potentially reversible brain ischemia, including magnetic resonance imaging (MRI) diffusion-perfusion, perfusion computed tomography (CT) and functional neuroimaging techniques includes positron emission tomography (PET) and single-photon emission tomography (SPECT). The aim of this study is to present our experience with a group of patients that presented with acute brain ischemia and had a NeuroSPECT evaluation before and after intra-arterial thrombolysis and/or possible stent placement, in the treatment of acute brain infarct. Methods: 16 patients were treated acutely for a significant ischemic stroke with the following protocol. 1) Admission, and complete neurological evaluation. 2) Brain CT scan performed to rule out hemorrhage or established infarct. 3) IV injection of 1100MBq Tc 99m HMPAO (Ceretec tm ) 4) Conventional cerebral angiography and intra-arterial thrombolysis with tPA and /or angioplasty/stent if necessary. 5) NeuroSPECT assessment of ischemic penumbra (Pre-therapy results). 6) 14 of 16 patients received a NeuroSPECT (Post-therapy results) control at 24 hours. NeuroSPECT image acquisition was performed immediately following arterial thrombolysis with a dual Head Camera, Siemens ECAM, SHR collimators and conventional protocol. Image processing was performed using the Neurogam, Segami Corp. Software as previously reported in Alasbimn Journal 2

  9. Delayed reflow of an ischemic infarct after spontaneous thrombolysis studied by CBF tomography using SPECT and Tc-99m HMPAO

    DEFF Research Database (Denmark)

    Companioni, J M; Lassen, N A; Tfelt-Hansen, P

    1991-01-01

    A patient with a large ischemic infarct in the left middle cerebral artery territory was studied six times in the acute/subacute phase by cerebral blood flow (CBF) tomography using Tc-99m-HMPAO. The SPECT instrument used was a brain dedicated highly sensitive four-camera system (TOMOMATIC 232...

  10. Brain SPECT imaging in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Krausz, Y.; Yaffe, S.; Atlan, H.; Cohen, D.; Konstantini, S.; Meiner, Z.

    1991-01-01

    Temporal lobe epilepsy is diagnosed by clinical symptoms and signs and by localization of an epileptogenic focus. A brain SPECT study of two patients with temporal lobe epilepsy, using 99m Tc-HMPAO, was used to demonstrate a perfusion abnormality in the temporal lobe, while brain CT and MRI were non-contributory. The electroencephalogram, though abnormal, did not localize the diseased area. The potential role of the SPECT study in diagnosis and localization of temporal lobe epilepsy is discussed. (orig.)

  11. Role of SPECT (HM-PAO, Tc99mRc) and ultrasound (TCD) in the instrumental diagnostic approach to the comprehension of reversible ischemic symptoms

    International Nuclear Information System (INIS)

    Liboni, W.; Baggiore, P.; Chianale, G.; Marta, G.; Castellano, G.; Cornaglia, G.

    1989-01-01

    The relation between variations of cerebral and acute neurologic events, followed by partial or total recovery, has been investigated with SPECT HM-PAO and with ultrasound (TRANSCRANIAL DOPPLER). (H.W.). 3 refs.; 2 figs.; 2 tabs

  12. Reduced brain perfusion in basal forebrain associated with cognitive decline in Alzheimer's diseases: a Tc-99m HMPAO SPECT study

    International Nuclear Information System (INIS)

    Lee, M.C.; Kang, H.; Kang, E.; Lee, J.S.; Lee, D.S.; Lee, D.W.; Cho, M.J.

    2002-01-01

    Aim: Reduction of regional cerebral blood flow (rCBF) in various cerebral regions and decline of cognitive function have been reported in Alzheimer's disease (AD) patients. The aim of this study was to identify the brain areas showing correlation between longitudinal changes of rCBFs and decline of general mental function, measured by Mini-Mental State Examination (MMSE) in probable Alzheimer's disease patients. Materials and Methods: Nine probable AD patients according to NINCDS-ADRDA criteria and DSM-IV were studied with Tc-99m HMPAO SPECT at an initial point and at the follow-up after a period of average 1.8 year. MMSE score was obtained in both occasions (average MMSE 16.4 at initial study; average MMSE = 8.1 at follow-up). Single SPECT was performed in 30 age-matched normal controls. Each SPECT image was normalized to the cerebellar activity. Using statistical parametric mapping (SPM99), correlation was analyzed between individual changes in rCBF of two SPECT scans and the MMSE scores at the time of each study in AD patients. In addition, the SPECT images of the initial study and the follow-up study were compared with SPECT images of the age-matched normal group respectively. Results: Significant correlation between longitudinal changes of rCBFs and MMSE scores was found in left basal forebrain region including substantia innominata (x, y, z = -24, 16, -23; P < .05, corrected). Within a short follow-up period of 1.8 years, cerebral hypoperfusion extended to various cortical regions from bilateral temporo-parietal to bilateral frontal regions and cingulate cortex, compared to normal controls. Conclusion: The decline of cognitive function in individual AD patients was correlated with rCBF reduction in left basal forebrain. This finding supports the cholinergic hypothesis of AD since hypoperfusion in basal forebrain region might indicate deterioration of cholinergic neurons in nucleus basalis of Meynert or substantia innominata

  13. Optimization of Butterworth filter for brain SPECT imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Maruno, Hirotaka; Yui, Nobuharu

    1993-01-01

    A method has been described to optimize the cutoff frequency of the Butterworth filter for brain SPECT imaging. Since a computer simulation study has demonstrated that separation between an object signal and the random noise in projection images in a spatial-frequency domain is influenced by the total number of counts, the cutoff frequency of the Butterworth filter should be optimized for individual subjects according to total counts in a study. To reveal the relationship between the optimal cutoff frequencies and total counts in brain SPECT study, we used a normal volunteer and 99m Tc hexamethyl-propyleneamine oxime (HMPAO) to obtain projection sets with different total counts. High quality images were created from a projection set with an acquisition time of 300-seconds per projection. The filter was optimized by calculating mean square errors from high quality images visually inspecting filtered reconstructed images. Dependence between total counts and optimal cutoff frequencies was clearly demonstrated in a nomogram. Using this nomogram, the optimal cutoff frequency for each study can be estimated from total counts, maximizing visual image quality. The results suggest that the cutoff frequency of Butterworth filter should be determined by referring to total counts in each study. (author)

  14. Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

    Science.gov (United States)

    Dierckx, R A; Saerens, J; De Deyn, P P; Verslegers, W; Marien, P; Vandevivere, J

    1991-08-01

    A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

  15. Validation and the limits of SPECT for patients suffering from cerebrovascular accidents. Evaluations based on simultaneous PET and SPECT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1989-02-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO{sub 2}) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO{sub 2} during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO{sub 2} on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO{sub 2} value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO{sub 2} areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.).

  16. An evaluation of the cerebral hemodynamics in moyamoya disease with acetazolamide (Diamox) 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Qin-Yi, Gao; Kuwabara, Yasuo; Ichiya, Yuichi

    1994-01-01

    We studied the cerebral hemodynamics using Diamox 99m Tc-HMPAO SPECT in 9 patients with moyamoya disease, consisting of 4 children and 5 adults. Diamox 99m Tc-HMPO SPECT studies were performed by the double injection method. Hypoperfusion areas were scored by a visual inspection as follows: ++, definite positive; +, probable positive; -, negative. Diamox test was interpreted as positive when the score increased over one degree. In the resting state, 6 out of 9 patients showed definite or probable positive hypoperfusion, while all of 9 patients showed a similar finding after Diamox injection. The Diamox test was positive in 6 out of 9 patients. It was positive in all 3 patients who showed a negative hypoperfusion in the resting state. The regional cerebrovascular response to Diamox was most severely impaired in the frontal region. However, it was relatively well preserved in the cerebellum and thalamus according to the semiquantiative analysis. Thus, the Diamox HOPAO SPECT was considered to be useful in evaluating the hemodynamics in patients with moyamoya disease. (author)

  17. Impact of SPECT/CT in imaging inflammation and infection; Wertigkeit der SPECT/CT fuer die nuklearmedizinische Entzuendungsdiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Linke, R. [Klinikum Bremen-Mitte, Bremen (Germany). Klinik fuer Nuklearmedizin; Kuwert, T. [Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik

    2011-03-15

    Even today infection remains a significant concern, and the diagnosis and localization of infectious foci is an important health issue. As an established infection-imaging modality, nuclear medicine plays a vital health-care role in the diagnosis and subsequent effective treatment of this condition. Several techniques in nuclear medicine significantly aid infection diagnosis, including triple-phase bone scanning, {sup 18}F-FDG-PET and imaging with {sup 111}In-oxine-, {sup 99m}Tc-HMPAO-labeled leukocytes. Each radiopharmaceutical has specific advantages and disadvantages that makes it suitable to diagnose different infectious processes (e.g., soft-tissue sepsis, inflammatory bowel disease, osteomyelitis, occult fever, fever of unknown origin, and infections commonly found in immuno-compromised patients). However, their clinical applications may be limited by the relatively low spatial resolution and the lack of anatomic landmarks of a highly specific tracer with only scarce background uptake to use as a framework for orientation. Anatomic imaging modalities such as CT provide a high-quality assessment of structural abnormalities related to infection, but these structural abnormalities may be unspecific. Furthermore, to detect infection before anatomical changes are present, functional imaging could have some advantages over anatomical imaging. Scintigraphic studies have demonstrated high sensitivity and specificity to an infectious process. Diagnosis and precise delineation of infection may be challenging in certain clinical scenarios, rendering decisions concerning further patient management difficult. The SPECT/CT-technology combines the acquisition of SPECT and CT data with the same imaging device enabling perfect overlay of anatomical and functional images. SPECT/CT imaging data has been shown to be beneficial for many clinical settings such as indeterminate findings in bone scintigraphy, orthopaedic disorders, endocrine, and neuroendocrine tumors. Therefore

  18. Ictal and interictal SPECT imaging of 8 patients with symptomatic partial epilepsy

    International Nuclear Information System (INIS)

    Motooka, Hiromichi

    1993-01-01

    Although epileptic discharges such as spike, spike and wave complex, sharp wave, and sharp and wave complex can be recorded by interictal scalp electroencephalography (EEG) in many patients with epilepsy, recent studies have demonstrated that no epileptic discharges can be recorded by interictal and ictal scalp EEGs in some patients who clinically exhibit epileptic seizures. Accordingly scalp EEG is not always helpful for diagnosing epilepsy or identifying the epileptic foci in the brain in these patients. Recently, studies using single photon emission computed tomography (SPECT) have been performed for patients with epilepsy and evidence that epileptic foci can be identified by changes in the regional cerebral blood flow (rCBF) seen on SPECT scanning have been accumulated. In the present study, therefore, 8 patients with medically intractable partial seizures were simultaneously or independently investigated by the recordings of scalp EEG and SPECT scanning during the interictal and ictal period. N-isopropyl-p[ 123 I]-iodoamphetamine ( 123 I-IMP) was used for SPECT scanning for 7 patients and 99m Tc-d,l-hexamethyl-propyleneamineoxime ( 99m Tc-HMPAO) for 1 patient. An increase in rCBF (hyperperfusion) or decrease in rCBF (hypoperfusion) were found in 4 patients by interictal SPECT imaging and in all patients by ictal SPECT imaging although epileptic discharges were observed in 3 patients by interictal scalp EEG and 5 patients by ictal scalp EEG. The findings of the present study indicate that ictal SPECT scanning is more useful for diagnosing epilepsy and identifying the epileptic foci in the brain than ictal scalp EEG. (author)

  19. Evaluation of hemodynamic effects of extracranial carotid stenoses by adenosine-induced vasodilatation in combination with 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Ussov, V.Yu.; Plotnikov, M.P.; Yaroshevsky, S.P.; Shipulin, V.M.; Sokolov, AA.

    1999-01-01

    Methods: Adenosine was evaluated in combination with 99mTc-HMPAO SPECT as an intravenous agent for the pharmacological stress-test of the regional cerebral blood flow (rCBF) in 12 patients with internal carotid artery (ICA) stenosis without neurologic deficit (8 subjects) or with minimal deficit (4 subjects). Also, the adenosine-induced effects on rCBF were correlated with the anatomic severity of ICA stenosis. Six normal age-matched volunteers served as control. Results: The rest 99mTc-HMPAO SPECT data did not reveal any significant interhemispheric asymmetry of perfusion either in ICA stenosis patients or in control subjects. No interhemispheric asymmetry was observed in control subjects during adenosine infusion either. In ICA stenosis the adenosine test did induce interhemispheric asymmetry of perfusion, which ranged between 0.73 and 0.96 when quantified as an interhemispheric ratio of 99mTc-HMPAO uptake. In 5 of the 12 patients with ICA stenosis, adenosine also elicited a short - term muscular weakness and/or skin paresthesia consistent with cerebral location of the related cortical zones in the stenosis - dependent hemisphere. No correlation was noted between the interhemispheric anatomic planimetric asymmetry of stenosis (as ratio of patent ICA vessel lumen areas) and perfusion asymmetry at rest. The planimetric asymmetry of stenosis correlated significantly with the adenosine-induced asymmetry of rCBF in ICA - dependent areas (r = 0.78, p < 0.02). The correlation could be observed beginning from the magnitude of 70-75% relatively to the cross-sectional area of the contralateral intact vessel, equivalent to 45-50% decrease in the arterial diameter as compared to the intact artery. Conclusion: Therefore, the conclusion can be drawn that adenosine as a potent cerebral vasodilatator may be employed as a challenging agent for functional tests of rCBF and that the adenosine test facilitates detection of the hemodynamic effects of ''minor'' stenoses. (author)

  20. 99mTc-HMPAO SPECT of the brain in mild to moderate traumatic brain injury patients: compared with CT--a prospective study.

    Science.gov (United States)

    Nedd, K; Sfakianakis, G; Ganz, W; Uricchio, B; Vernberg, D; Villanueva, P; Jabir, A M; Bartlett, J; Keena, J

    1993-01-01

    Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.

  1. Types of traumatic brain injury and regional cerebral blood flow assessed by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Yamakami, Iwao; Yamaura, Akira; Isobe, Katsumi

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with 99m technetium-hexamethyl propyleneamine oxime (HMPAO). Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated: 1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, 2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and 3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient. (author)

  2. SPECT brain perfusion abnormalities in mild or moderate traumatic brain injury.

    Science.gov (United States)

    Abdel-Dayem, H M; Abu-Judeh, H; Kumar, M; Atay, S; Naddaf, S; El-Zeftawy, H; Luo, J Q

    1998-05-01

    The purpose of this atlas is to present a review of the literature showing the advantages of SPECT brain perfusion imaging (BPI) in mild or moderate traumatic brain injury (TBI) over other morphologic imaging modalities such as x-ray CT or MRI. The authors also present the technical recommendations for SPECT brain perfusion currently practiced at their center. For the radiopharmaceutical of choice, a comparison between early and delayed images using Tc-99m HMPAO and Tc-99m ECD showed that Tc-99m HMPAO is more stable in the brain with no washout over time. Therefore, the authors feel that Tc-99m HMPAO is preferable to Tc-99m ECD. Recommendations regarding standardizing intravenous injection, the acquisition, processing parameters, and interpretation of scans using a ten grade color scale, and use of the cerebellum as the reference organ are presented. SPECT images of 228 patients (age range, 11 to 88; mean, 40.8 years) with mild or moderate TBI and no significant medical history that interfered with the results of the SPECT BP were reviewed. The etiology of the trauma was in the following order of frequency: motor vehicle accidents (45%) followed by blow to the head (36%) and a fall (19%). Frequency of the symptoms was headache (60.9%), memory problems (27.6%), dizziness (26.7%), and sleep disorders (8.7%). Comparison between patients imaged early (3 months) from the time of the accident, showed that early imaging detected more lesions (4.2 abnormal lesions per study compared to 2.7 in those imaged more than 3 months after the accident). Of 41 patients who had mild traumatic injury without loss of consciousness and had normal CT, 28 studies were abnormal. Focal areas of hypoperfusion were seen in 77% (176 patients, 612 lesions) of the group of 228 patients. The sites of abnormalities were in the following order: basal ganglia and thalami, 55.2%, frontal lobes, 23.8%, temporal lobes, 13%, parietal, 3.7%, insular and occipital lobes together, 4.6%.

  3. The validation and the limits of SPECT for patients suffering from cerebrovascular accidents

    International Nuclear Information System (INIS)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi

    1989-01-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO 2 ) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO 2 during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO 2 on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO 2 value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO 2 areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.)

  4. A case of Cotard syndrome: (123)I-IBZM SPECT imaging of striatal D(2) receptor binding.

    Science.gov (United States)

    De Risio, Sergio; De Rossi, Giuseppe; Sarchiapone, Marco; Camardese, Giovanni; Carli, Vladimir; Cuomo, Chiara; Satta, Maria Antonietta; Di Giuda, Daniela

    2004-01-15

    A case of 'dèlire de nègation' that suddenly appeared in a 43-year-old male is presented. No alteration in regional cerebral blood, as measured by (99m)Tc-HMPAO-SPECT, was found, but (123)I-IBZM-SPECT analysis showed reduced striatal D(2) receptor binding that further decreased after treatment.

  5. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  6. In vitro assessment of cytotoxicity and labeling efficiency of 99mTc-HMPAO with stromal vascular fraction of adipose tissue

    International Nuclear Information System (INIS)

    Verma, V.K.; Beevi, S.S.; Tabassum, A.; Kumaresan, K.; Kamaraju, R.S.; Arbab, A.S.; Chelluri, L.K.

    2014-01-01

    Introduction: Noninvasive radionuclide imaging of cells using technetium99m-hexamethylpropyleneamine oxime ( 99m Tc-HMPAO) is a potential diagnostic tool for several applications. Herein we aimed to evaluate the labeling efficiency and cellular toxicity of 99m Tc-HMPAO with Stromal Vascular Fraction (SVF) of adipose tissue to develop a process tool for theranostic purposes, in particular imaging cardiac stem cell therapy. Methods: Ten million cells of SVF were labeled with 99m Tc-HMPAO complex and excess radiolabel was cleared off through washing in PBS. The labeling efficiency of 99m Tc-HMPAO was detected in labeled cells and their subsequent supernatant wash using isotope dose calibrator and gamma camera. The cytotoxicity was assessed for the comparative reactive oxygen species (ROS) by H 2 DCFDDA, apoptotic events by annexin-V and TUNEL assay and mitochondrial potential by JC-1. Results: An encouraging labeling efficiency of 33% was observed with 99m Tc-HMPAO complex. The radionuclide labeling of SVF demonstrated significant safety profile as evaluated by apoptotic assays. Conclusion: 99m Tc-HMPAO labeling efficiency of 33% of total SV fraction would produce sufficient radioactive signals that would enable for in vivo tracking of cells by SPECT-CT. The radionuclide did not demonstrate any significant impact on the structural or functional organization of the labeled cells. Our study indicates that SVF can be safely labeled with 99m Tc-HMPAO without adverse cytotoxic events and for its potential role in imaging cardiac stem cell therapy

  7. Types of traumatic brain injury and regional cerebral blood flow assessed by [sup 99m]Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Iwao; Yamaura, Akira; Isobe, Katsumi [Chiba Univ. (Japan). School of Medicine

    1993-01-01

    To investigate the relationship between focal and diffuse traumatic brain injury (TBI) and regional cerebral blood flow (rCBF), rCBF changes in the first 24 hours post-trauma were studied in 12 severe head trauma patients using single photon emission computed tomography (SPECT) with [sup 99m]technetium-hexamethyl propyleneamine oxime (HMPAO). Patients were classified as focal or diffuse TBI based on x-ray computed tomographic (X-CT) findings and neurological signs. In six patients with focal damage, SPECT demonstrated: (1) perfusion defect (focal severe ischemia) in the brain region larger than the brain contusion by X-CT, (2) hypoperfusion (focal CBF reduction) in the brain region without abnormality by X-CT, and (3) localized hyperperfusion (focal CBF increase) in the surgically decompressed brain after decompressive craniectomy. Focal damage may be associated with a heterogeneous CBF change by causing various focal CBF derangements. In six patients with diffuse damage, SPECT revealed hypoperfusion in only one patient. Diffuse damage may be associated with a homogeneous CBF change by rarely causing focal CBF derangements. The type of TBI, focal or diffuse, determines the type of CBF change, heterogeneous or homogeneous, in the acute severe head trauma patient. (author).

  8. Evaluation of brain perfusion SPECT imaging using 99mTc-ECD

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Kinuya, Keiko; Higashi, Sotaro; Kawasaki, Yasuhiro; Sumiya, Hisashi; Shuke, Noriyuki; Hisada, Kinichi; Yamashita, Junkoh; Yamaguchi, Nariyoshi

    1991-01-01

    Fundamental and clinical evaluation was performed on 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD), that is a new agent for brain perfusion SPECT. Radiochemical purity reaches a plateau of approximately 98% at 30 min after reconstruction and remains stable up to 24 hours later. A biodistribution study showed approximately 5% injected dose in the brain, very slow brain washout of 5.6% per hour on the average, and rapid washout from the other organ mainly through the urinary system. Brain ECD distribution was determined within 2 min postinjection and remained stable for up to 1 hour. Three hours later, slight but significant changes in brain distribution were observed, that were relative reduction of cerebral cortical activity and gray to white matter activity ratio, and relative elevation of white matter and thalamic activities. Comparative studies of ECD images with 123 I-iodoamphetamine (IMP) and 99m Tc-d, l-hexa-methylpro-pyleneamine oxime (HMPAO) images revealed that radioactivity contrast between affected and unaffected areas was less prominent in ECD than in IMP in cerebral and cerebellar cortical lesions, more prominent in ECD than in IMP in striatal and thalamic lesions, and somewhat more prominent in ECD than in HMPAO in both lesions. Imaging around 1 hour postinjection seems to be more appropriate than immediate postinjection imaging because of the clearance of the extracranial radioactivity and somewhat better radioactivity contrast between affected and unaffected areas. (author)

  9. The role of Tc-99m HMPAO brain perfusion SPECT in the psychiatric disability evaluation of patients with chronic traumatic brain injury

    Energy Technology Data Exchange (ETDEWEB)

    So, Young [Nuclear Medicne, Seoul National Univ., Seoul (Korea, Republic of); Lee, Kang Wook; Lee, Sun Woo; Ghi, Lek Sung; Song, Chang June [College of Medicine, Chungnam National Univ., Taejon (Korea, Republic of)

    2002-08-01

    We studied whether brain perfusion SPECT is useful in the psychiatric disability evaluation of patients with chronic traumatic brain injury (TBI). Sixty-nine patients (M:F=58:11, age 39 {+-} 14 years) who underwent Tc-99m HMPAO brain SPECT, brain MRI and neuropsychological (NP) tests during hospitalization in psychiatric wards for the psychiatric disability evaluation were included; the severity of injury was mild in 31, moderate in 17 and severe in 21. SPECT, MRI, NP tests were performed 6 {approx} 61 months (mean 23 months) post-injury. Diagnostic accuracy of SPECT and MRI to show hypoperfusion or abnormal signal intensity in patients with cognitive impairment represented by NP test results were compared. Forty-two patients were considered to have cognitive impairment on NP tests and 27 not. Brain SPECT showed 71% sensitivity and 85% specificity, while brain MRI showed 62% sensitivity and 93% specificity (p>0.05, McNemar test). SPECT found more cortical lesions and MRI was superior in detecting white matter lesions. sensitivity and specificity of 31 mild TBI patients were 45%, 90% for SPECT and 27%, 100% for MRI (p>0.05, McNemar test). Among 41 patients with normal brain MRI, SEPCT showed 63% sensitivity (50% for mild TBI) and 88% specificity (85% for malingerers). Brain SPECT has a supplementary role to neuropsychological tests in the psychiatric disability evaluation of chronic TBI patients by detecting more cortical lesions than MRI.

  10. The role of Tc-99m HMPAO brain perfusion SPECT in the psychiatric disability evaluation of patients with chronic traumatic brain injury

    International Nuclear Information System (INIS)

    So, Young; Lee, Kang Wook; Lee, Sun Woo; Ghi, Lek Sung; Song, Chang June

    2002-01-01

    We studied whether brain perfusion SPECT is useful in the psychiatric disability evaluation of patients with chronic traumatic brain injury (TBI). Sixty-nine patients (M:F=58:11, age 39 ± 14 years) who underwent Tc-99m HMPAO brain SPECT, brain MRI and neuropsychological (NP) tests during hospitalization in psychiatric wards for the psychiatric disability evaluation were included; the severity of injury was mild in 31, moderate in 17 and severe in 21. SPECT, MRI, NP tests were performed 6 ∼ 61 months (mean 23 months) post-injury. Diagnostic accuracy of SPECT and MRI to show hypoperfusion or abnormal signal intensity in patients with cognitive impairment represented by NP test results were compared. Forty-two patients were considered to have cognitive impairment on NP tests and 27 not. Brain SPECT showed 71% sensitivity and 85% specificity, while brain MRI showed 62% sensitivity and 93% specificity (p>0.05, McNemar test). SPECT found more cortical lesions and MRI was superior in detecting white matter lesions. sensitivity and specificity of 31 mild TBI patients were 45%, 90% for SPECT and 27%, 100% for MRI (p>0.05, McNemar test). Among 41 patients with normal brain MRI, SEPCT showed 63% sensitivity (50% for mild TBI) and 88% specificity (85% for malingerers). Brain SPECT has a supplementary role to neuropsychological tests in the psychiatric disability evaluation of chronic TBI patients by detecting more cortical lesions than MRI

  11. Comparison of brain perfusion SPECT and MRI findings in children with neuronal ceroid-lipofuscinosis and in their families

    International Nuclear Information System (INIS)

    Sayit, E.; Yorulmaz, I; Gumuser, F.G.; Dirik, E.; Bekis, R.; Kaya, G.; Durak, H.

    2002-01-01

    Neuronal ceroid-lipofuscinoses (NCL) are among the progressive encephalopathies of childhood that are inherited in an autosomal recessive manner. In this study we specifically aimed to investigate any white-matter changes in the carriers (parents) and the healthy siblings of individuals with neuronal ceroid lipofuscinosis disease and whether we may be able to predict the occurrence of any neurological symptoms in healthy children in the future thus enabling early management. Since the NCLs are genetically determined diseases, we investigated fifteen individuals in three families that had diseased children of the juvenile type, with brain perfusion SPECT and MRI. Brain perfusion SPECT was performed after administering 222-555 MBq (6-15 mCi) Tc-99m hexamethyl-propylene amine oxime (HMPAO) intravenously in a dimmed and quiet room. Imaging was performed at least one hour after injection, with a three headed gamma camera equipped with high resolution collimators. A Metz filter (FWHM: 11 mm) was used for processing. Cranial MRI was performed with an imager operating at 1.5 Tesla. Spin-echo T1- and T2-weighted and FLAIR slices were obtained for each individual. In all of the five diseased children we observed pathologic findings both on MRI and Tc-99m HMPAO SPECT. The findings on MRI were mainly features of cerebral and cerebellar atrophy and the observations on Tc-99m HMPAO SPECT were regional perfusion abnormalities. We observed some structural abnormalities on MRI in four of the parents and two of the four healthy siblings. We also noted perfusion abnormalities on Tc-99m HMPAO SPECT in two of the parents and two of the healthy siblings. Because the disease is inherited in an autosomal recessive manner, the parents and the healthy siblings were not supposed to exhibit any demonstrable brain lesions, but the brain perfusion SPECT and MRI examinations clearly revealed multiple lesions in some of the parents and healthy siblings. Detailed neurological examinations of these

  12. Cerebral fat embolism studied with MRI and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Erdem, E. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Namer, I.J. (Inst. of Biophysics, Faculty of Medicine, Louis Pasteur Univ., Strasbourg (France)); Saribas, O. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Aras, T. (Dept. of Nuclear Medicine, Hacettepe Univ. School of Medicine Ankara (Turkey)); Tan, E. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey)); Bekdik, C. (Dept. of Nuclear Medicine, Hacettepe Univ. School of Medicine Ankara (Turkey)); Zileli, T. (Dept. of Neurology, Hacettepe Univ. School of Medicine, Ankara (Turkey))

    1993-03-01

    In a patient with fat embolism to the brain CT showed no abnormality. MRI performed after recovery from coma, when the patient had aphasia and quadriparesis, demonstrated multiple high signal abnormalities in the white matter on both T1- and T2-weighted images. HMPAO-SPECT showed left-sided hypoperfusion which resolved in parallel with clinical improvement 1 month later. (orig.)

  13. In vitro assessment of cytotoxicity and labeling efficiency of {sup 99m}Tc-HMPAO with stromal vascular fraction of adipose tissue

    Energy Technology Data Exchange (ETDEWEB)

    Verma, V. K.; Beevi, S. S. [Department of Transplant Biology, Immunology and Stem Cell Lab, Global Hospitals, Hyderabad (India); Tabassum, A.; Kumaresan, K. [KK Nuclear Scans, Raj Bhavan Road, Somajiguda, Hyderabad (India); Kamaraju, R. S. [Department of Transplant Biology, Immunology and Stem Cell Lab, Global Hospitals, Hyderabad (India); Arbab, A. S. [Cancer Centre, GA Regents University, Augusta, GA (United States); Chelluri, L.K., E-mail: lkiran@globalhospitalsindia.com [Department of Transplant Biology, Immunology and Stem Cell Lab, Global Hospitals, Hyderabad (India)

    2014-10-15

    Introduction: Noninvasive radionuclide imaging of cells using technetium99m-hexamethylpropyleneamine oxime ({sup 99m}Tc-HMPAO) is a potential diagnostic tool for several applications. Herein we aimed to evaluate the labeling efficiency and cellular toxicity of {sup 99m}Tc-HMPAO with Stromal Vascular Fraction (SVF) of adipose tissue to develop a process tool for theranostic purposes, in particular imaging cardiac stem cell therapy. Methods: Ten million cells of SVF were labeled with {sup 99m}Tc-HMPAO complex and excess radiolabel was cleared off through washing in PBS. The labeling efficiency of {sup 99m}Tc-HMPAO was detected in labeled cells and their subsequent supernatant wash using isotope dose calibrator and gamma camera. The cytotoxicity was assessed for the comparative reactive oxygen species (ROS) by H{sub 2}DCFDDA, apoptotic events by annexin-V and TUNEL assay and mitochondrial potential by JC-1. Results: An encouraging labeling efficiency of 33% was observed with {sup 99m}Tc-HMPAO complex. The radionuclide labeling of SVF demonstrated significant safety profile as evaluated by apoptotic assays. Conclusion: {sup 99m}Tc-HMPAO labeling efficiency of 33% of total SV fraction would produce sufficient radioactive signals that would enable for in vivo tracking of cells by SPECT-CT. The radionuclide did not demonstrate any significant impact on the structural or functional organization of the labeled cells. Our study indicates that SVF can be safely labeled with {sup 99m}Tc-HMPAO without adverse cytotoxic events and for its potential role in imaging cardiac stem cell therapy.

  14. Cerebral perfusion study using 99mTc-HMPAO-ECT: Particular aspects regarding uptake and evaluation

    International Nuclear Information System (INIS)

    Spitz, J.; Clemenz, N.

    1988-01-01

    From the performance of about 250 99m Tc-HMPAO-SPECT studies for clarification of cerebro-vascular diseases, five essential problem groups have emerged: 1. Positioning of the patient's head and hence resulting rotation radius of the camera head. 2. Choice of the slice level for documentation and demonstration of the ECT study. 3. Standardization and colour codation of the single slice images. 4. Localization and identification of single slices in different slice levels. 5. Quantification of the distribution pattern. Whether nuclear medical cerebral perfusion study for diagnosis of cerebro-vascular diseases using 99m Tc-HMPAO may be an equivalent to DSA und TCT in future, should at least partially depend upon an adequate answer to the presented problems. (orig.) [de

  15. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  16. Quantitative Analysis of Regional Cerebral Blood Flow using 99mTc-HMPAO SPECT in Parkinson's Disease

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin; Lee, Myung Hae

    1992-01-01

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using 99m Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 ± 0.033 and 0.108 ± 0.062, respectively and PIA were -0.4 ± 0.7% and -0.7 ± 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  17. Findings of 99mTc-HMPAO Regional Cerebral Blood Flow SPECT in a Case of Herpes Simplex Encephalitis

    International Nuclear Information System (INIS)

    Ahn, Myeong Im; Lee, Sung Yong; Kim, Jong Woo; Bahk, Yong Whee

    1989-01-01

    Herpes simplex encephalitis (HSE) is one of the fulminant necrotizing, often fatal sporadic form of the encephalitis caused by herpes simplex type I virus. Characteristically, there is early and almost constant involvement of one or both temporal lobes, although there are common additional areas of involvement. Appropriate early treatment following correct diagnosis by clinical findings, CSF study, EEG and several radiological studies including angiography, radionuclide studies, CT or MRI can reduce its mortality and severity of the sequelae. We report a case of HSE diagnosed by adjuvant study of 99m Tc-HMPAO regional cerebral blood flow SPECT, which showed a marked increase in bitemporal cerebral blood flow in a 24-year-old man.

  18. Brain perfusion ratios by 99mTc HMPAO SPECT utilizing a mean value of the visual cortex to the cerebellum ratio derived from normal subjects

    International Nuclear Information System (INIS)

    Sanchez Catasus, C.; Rodriguez, R.; Cisnero, M.; Palmero, R.; Diaz, O.; Aguila, A.

    2002-01-01

    Aim: Previous results shows that the cerebellum (CER) is the best reference to calculate relative indexes of perfusion (IP) by brain SPECT. However, it can not be used on patients with bilateral cerebellar hypoperfusion. In such cases visual cortex (VC) or an average of the whole brain activity is recommended (WB). VC and WB are less reliable than CER, making it difficult to compare SPECT scans that have been normalized with different values. Materials and Methods: To overcome this difficulty, we developed a method to calculate IP utilizing a reference value defined as (VC / ), where is the mean value of the VC/CER ratio derived from a normal database which was assumed to be constant. We called the value VC/ the 'Pseudocerebellum' (PCER). For clinical validation, we first tested statistically the VC/CER ratio on a group of 60 [ 99m Tc]-HMPAO SPECT scans of 20 normal subjects and 40 neurological patients with positive SPECT but without involvement of VC and CER. To demonstrate that IP PCER approx. IP CER , we calculated the mean value of the absolute differences CER - IP PCER vertical bar> on two groups of scans from subjects without involvement of VC and CER: 10 normal subjects (GI); and 40 patients (GII). Finally, using an indirect procedure the method was tested on a third group of SPECT scans of 30 patients with bilateral cerebellar hypoperfusion (G III). Results: The VC/CER ratio was approximately constant with gender and age at a 95% confidence level; CER - IP PCER vertical bar> was 1.22%±0.35 and 1.20%±0.42 for GI and GII, respectively. This is less than the within-subject replicability of the HMPAO SPECT studies; and thus demonstrated by an indirect approach that IP PCER is a valid procedure by which to evaluate relative perfusion on patients with bilateral cerebellar hypoperfusion and quantitatively comparable to using CER as reference region. Conclusion: The VC/CER ratio has very little inter-subject variability in individuals where these regions are not

  19. Technetium-99m HMPAO labeled leukocytes in inflammation imaging

    International Nuclear Information System (INIS)

    Uno, Kimiichi; Yoshikawa, Kyousan; Imazeki, Keiko; Minoshima, Satoshi; Arimizu, Noboru

    1991-01-01

    Technetium-99m-HMPAO (Tc-99m-HMPAO) labeled leukocyte imaging was carried out in 19 patients at 3-5 hr after reinjection. There were no side effects noted. Tc-99m leukocyte images showed gall bladder, colon, kidney, and urinary bladder activity in normal distribution as a result of excretion of the eluted Tc-99m complex. They yielded a sensitivity of 93%, a specificity of 100% and an accuracy of 95%. They were correctly positive in 14 out of 19 cases. But one false negative case was seen in a patient with pyonephrosis showing a lack of renal function with decreased renal blood flow. It was concluded that they have some advantages over In-111 leukocyte images, but we have to consider the fact that the ureteral obstruction or the lack of renal function with decreased renal blood flow may result in a false positive or a false negative case. (author)

  20. Evaluation of lung injury induced by pingyangmycin with 99Tcm-HMPAO lung imaging

    International Nuclear Information System (INIS)

    Zhao Changjiu; Yang Zhijie; Fu Peng; Zhang Rui

    2005-01-01

    Objective: To investigate the lung uptake of 99 Tc m -hexamethyl propylene amine oxime (HMPAO) in pingyangmycin-induced lung injury and its mechanism. Methods: 24 white rabbits were randomly divided into 4 groups. Group I: the control with normal diet. In group II, III and IV 0.2, 0.3 and 0.5 mg/kg pingyangmycin were given respectively by marginal vein of ear every other day. 99 Tc m -HMPAO static lung imaging was performed before and 8, 16, 24, 32 d after injection of pingyangmycin. 7 pixel x 5 pixel regions of interest (ROIs) were drawn on the right lung(R) and right upper limb(B), R/B were calculated. Also, 2 ml venous blood was withdrawn for measurement of endothelin by radioimmunoassay. 16 d after pingyangmycin in group IV and 32 d in group I, II and III, all the rabbits were sacrificed. Both lungs were examined immediately under light and electron microscopy. Results: Compared with the control group, there were statistical differences of 99 Tc m -HMPAO lung uptake in group II, III and IV (P 99 Tc m -HMPAO lung imaging can detect early pingyangmycin-induced lung injury. The endothelium of lung microcapillary is presumably the main location site of 99 Tc m -HMPAO abnormal concentration. (authors)

  1. Single photon emission computed tomography (SPECT) in seizure disorders in childhood

    International Nuclear Information System (INIS)

    Vles, J.S.H.; Demandt, E.; Ceulemans, B.; de Roo, M.; Casaer, P.J.M.

    1990-01-01

    In 38 children with partial seizures, the EEG, CT and NMR findings were compared to the results obtained with Tc99m HMPAO single photon emission computed tomography (SPECT) in order to determine whether SPECT is a useful adjunct to EEG, CT and NMR in this age group. In 3 out of 7 patients with a normal EEG, SPECT showed focal abnormalities. Nine patients whose EEGs did not show adequate lateralization had an abnormal SPECT which revealed a focus. In 14 out of 21 patients with a normal CT, SPECT showed focal changes in 13 patients and diffuse changes in the other one. In 7 out of 12 patients with a normal NMR, SPECT showed focal abnormalities. Although clinical history and a careful description of the seizures are the most valuable information in partial seizure disorders, SPECT imaging gives valuable additional information, which might target treatment. SPECT was superior to CT and NMR with respect to the depiction of some kind of abnormality. (author)

  2. Cranial MR imaging and cerebral 99mTc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    International Nuclear Information System (INIS)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-01-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and 99m Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOX) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS = III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (au) (18 refs.)

  3. Cranial MR imaging and cerebral 99mTc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    International Nuclear Information System (INIS)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-01-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and 99m Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOS) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS=III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (orig.)

  4. 99mTc-HMPAO perfusion indices and brain-mapping in stroke patients

    International Nuclear Information System (INIS)

    Minchev, D.; Klisarova, A.

    1997-01-01

    It is the purpose of the study to establish correlations between 99mTc-HMPAO (hexamethylpropylenaminoxym) perfusion indices and changes in brain-mapping among patients with acute stroke. Forty-six patients with definitely proved stroke syndrome are investigated in the first 72 hours and 15 days after the onset of cerebrovascular accident using clinical, neuro-physiological and 99mTc-HMPAO SPECT methods. Regional and hemispheric perfusion asymmetry correlate with the brain-mapping cerebral disturbance (p < 0.001). In patients presenting focal hypoperfusion there is a significant correlation between perfusion indices and local EEG disturbance (r = 0.87). The dynamic study demonstrates a significant correlation between perfusion indices and electrical cerebral disturbance in the first 72 hours after the onset of the cerebrovascular accident. Fifteen days later no such correlation is documented. The obtained results demonstrate the essential practical bearing of 99mTc-HMPAO SPECT indices on the objective assessment of perfusion hemispheric and regional asymmetry in stroke patients, and the possibility of being used for indirect estimation of the regional cerebral blood flow in acute stroke patients against the background of visual and quantitative EEG changes (author)

  5. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    International Nuclear Information System (INIS)

    Sundstroem, Torbjoern; Riklund, Katrine Aa.; Elgh, Eva; Naesman, Birgitta; Larsson, Anne; Nyberg, Lars

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2±4.8 years) with mild AD and 18 healthy elderly (69.4±3.9 years) were included in the study. The subjects were injected with 99m Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF 99m Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  6. Quantitative Analysis of Regional Cerebral Blood Flow using {sup 99m}Tc-HMPAO SPECT in Parkinson's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Chul; Bae, Sang Kyun; Chung, June Key; Koh, Chang Soon; Roh, Jae Kyu; Myung, Ho Jin [Seoul National University College of Medicine, Seoul (Korea, Republic of); Lee, Myung Hae [Asan Medical Center, Seoul (Korea, Republic of)

    1992-07-15

    Regional cerebral blood flow were measured in 10 patients with Parkinson's disease and 12 normal persons using {sup 99m}Tc-HMPAO SPECT. Reconstructed images were interpreted qualitatively and were compared with those findings of CT. For the quantitative analysis, six pairs of region of interest matched with the perfusion territories of large cerebral arteries and cerebellar hemisphere were determined. From the count values, indices showing the degree of asymmetry between right and left cerebral or cerebellar hemisphere, cerebral asymmetry index (ASI) and percent index of cerebellar asymmetry (PIA), and an index showing change of each region, region to cerebellum ratio (RCR) were obtained. ASI of normal persons and patients were 0.082 +- 0.033 and 0.108 +- 0.062, respectively and PIA were -0.4 +- 0.7% and -0.7 +- 1.0%, respectively, which showed no statistically significant difference between normal persons and patients. Among 10 RCR's, those of both regions of basal ganglia and both regions of anterior cerebral artery were significantly reduced. We concluded that the most significant reduction of regional cerebral blood flow in patients with Parkinson's disease was observed in the regions of basal ganglia and in the regions of anterior cerebral artery, and the degree of change in hemispheric blood flow was similar in both hemisphere.

  7. Cranial MR imaging and cerebral [sup 99m]Tc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-11-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and [sup 99m]Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOX) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS = III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (au) (18 refs.).

  8. SPECT in patients with cortical visual loss.

    Science.gov (United States)

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  9. Cerebral perfusion (HMPAO-SPECT) in patients with depression with cognitive impairment versus those with mild cognitive impairment and dementia of Alzheimer's type: a semiquantitative and automated evaluation

    International Nuclear Information System (INIS)

    Staffen, W.; Bergmann, J.; Schoenauer, U.; Kronbichler, M.; Golaszewski, S.; Ladurner, G.; Zauner, H.

    2009-01-01

    Comparative evaluation of regional brain perfusion measured by HMPAO-SPECT of patients with mild cognitive impairment (MCI), dementia of Alzheimer's type (DAT) and depression with cognitive impairment (DCI). A total of 736 patients were investigated because of suspected cognitive dysfunction. After exclusion of patients with other forms of dementia than DAT or relevant accompanying disorders, SPECT data from 149 MCI, 131 DAT and 127 DCI patients, and 123 controls without any cognitive impairment, were analysed. Relative cerebral blood flow of 34 anatomical regions was assessed with automated analysis software (BRASS). Calculation of global forebrain perfusion discriminated demented from nondemented patients. Compared to controls DCI patients showed hypoperfusion of the thalamus, lentiform nucleus and medial temporal cortex. MCI patients differed significantly from controls concerning perfusion in both hemispheric temporal and parietal areas, and in the (right hemispheric) posterior part of the cingulate gyrus. MCI and DCI patients differed in the parietal, temporal superior and right hemispheric cingulate gyrus posterior cortices. Global forebrain and regional perfusion was more extensively reduced in DAT patients and discriminated them from controls, and MCI and DCI patients. Frontal perfusion disturbance was only present in DAT patients. Automated analysis of HMPAO-SPECT data from MCI patients showed significant perfusion deficits in regions also involved in DAT patients, but ROC analysis demonstrated only moderate sensitivity and specificity for differentiating DAT patients from controls and DCI patients. Frontal hypoperfusion seems to correspond with conversion from MCI to DAT. Finally, the results in DCI patients again raise the question of depression as an early symptom of neurodegeneration. (orig.)

  10. Scintigraphic evaluation of brain death with 99mTc-d,l-hexamethyl-propyleneamine oxime (HMPAO)

    International Nuclear Information System (INIS)

    Takehara, Yasuo; Isoda, Haruo; Sakai, Tsuneo; Tanaka, Tokutaro; Sato, Haruhiko; Yamamoto, Takamichi; Takahashi, Motoichiro; Kaneko, Masao.

    1989-01-01

    Lately, the criteria of brain death is being discussed. Cerebral scintigram, especially scintigraphic evaluation of brain death by dynamic study, has been previously reported. Cerebral imaging using radiolabeled amines such as 123 I-IMP N-isopropyl-p-iodoamphetamin (IMP) or 99m Tc d, l-hexamethyl-propyleneamine oxime (HMPAO) offers a significant information of brain death by the finding of 'non visualized brain'. However, the dynamic scintigram acquired during the bolus injection of 99m Tc-HMPAO provides an additional information of brain death by classical 'hot nose sign'. 99m Tc-HMPAO is able to be administered relatively in a large amount of dose. This cerebral perfusion tracer is lipophilic and remains in the central nervous system, which characterize its role as a reliable indicator of cerebral blood flow. As a result, this compound became suitable for the non-invasive study of brain circulation when the diagnosis of brain death is uncertain. We report a case of brain death in which diagnosis was made by the classical 'hot nose sign' in dynamic scintigraphy performed when 99 mTc-HMPAO was injected as well as the SPECT which showed a lack of cerebral visualization at the equilibrium state. As far as we are informed, this additional procedure used in the diagnosis of brain death has not reported before. The importance of performing a dynamic scintigram at the administration of 99m Tc-HMPAO is also discussed in this report. (author)

  11. A review SPECT in neuropsychiatric disorders: neuro biological background, methodology, findings and future perspectives

    International Nuclear Information System (INIS)

    Gardner, Ann; Pagani, Marco

    2003-01-01

    The origin of altered radiotracer uptake and distribution in functional brain imaging studies, often considered to reflect regional cerebral blood flow (rCBF), in psychiatric disorders is unknown. Interpreting the magnitude of changes as changes in the magnitude of neuronal activity may be reasonable during normal circumstances, but less reliable in pathologic states. Results of published 99mTc-HMPAO SPECT studies in unmedicated patients with schizophrenia and major depression are discussed in the light of 99mTc-HMPAO properties, and reported findings of altered cell morphology and biochemistry, with emphasis on energy metabolism. We conclude that the SPECT technique using radiotracers with known biochemical properties will become useful in the understanding of cellular dysfunctions at different phases of neuropsychiatric disorders, and that use of automatic interpretation of three-dimensional volumes will allow for easier identification of regional neural correlates of the different psychiatric symptoms (Au)

  12. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  13. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  14. 99mTc-HMPAO Labelled WBC Scan in Experimental Abscess by Labelling Autologous Leukocytes with In-House-Synthesized HMPAO

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Shin, Hyung Sik; Ahn, Curie; Chung, June Key; Lee, Myung Chul; Choi, Kang Won; Koh, Chang Soon; Jung, Jae Min; Chung, Eun Ju

    1991-01-01

    With HMPAO we have synthesized in our laboratory, we labelled 99m Tc to canine leukocytes. Experimental abscess made by subcutaneous injection with Staphylococcus aureus was imaged with these 99m Tc labelled leukocytes. Labelling efficiency of HMPAO with 99m Tc was 66.2% ± 14.6% (N=9). Labelling efficiency of leukocytes with 99m Tc-HMPAO was 54% ± 7.79 (N=7). Cell bound radio activity in 99m Tc-HMPAO labelled leukocytes was around 80%. when these cells were incubated in plasma in vitro at 37 .deg. C for 5 hours. In vivo cell bound activity was over 80% at 24 hours after injection. One day and four days after inoculation, uptake at the inflammatory focus was found with 99m Tc labelled leukocytes. Uptake showed up in 4 hour image, and the uptake at the lesion was most prominent in 24 hour image. These findings show that in-house-synthesized HMPAO could be used for labelling leukocytes with 99m Tc, and that 99m Tc-HMPAO-labelled leukocytes were so stable and viable that inflammatory focus could be visualized with these 99m Tc-labelled leukocytes.

  15. Change of cerebral blood flow distribution and vascular reserver according to age in Koreans measured by Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Song, Ho Cheon; Bom, Hee Seung; Sohn, Hye Kyung; Jeong, Hwan Jeong; Min, Jung Jun; Kim, Ji Yeol; Lee Jae Tae; Moon, Dae Hyuk; Lee, Hee Kyung

    1999-01-01

    The aim of this study was to evaluate the normal values of regional cerebral blood flow (rCBF) and cerebrovascular reserve (CVR) in normal children to aged volunteers using Tc-99m HMPAO. Thirty four right-handed normal volunteers (20 males, 14 females, mean age 40.3±24.9 years, range 4 to 82 years) were underwent rest/acetazolamide (ACZ) brain SPECT using Tc-99m HMPAO and the sequential injection and subtraction method. rCBF was estimated on the basis of a semiquantitative approach by means of right/left ratio, region/cerebellum and region to whole brain ratios in frontal, parietal, temporal, and occipital lobes, basal ganglia, thalami, and cerebellum. CVR was measured by means of % perfusion increase calculated as % mean count change compared to rest rCBF in each regions. Mean values of right to left ratios range from 1.004 to 1.018. rCBF was highest in cerebellum and lowest in basal ganglia and thalami. Frontal and temporal rCBF decreased while occipital and thalamic rCBF increased according to age. No sexual difference of rCBF was noted. Mean CVR was 29.9±12.9%. Mean CVR significantly increased to late teens, and declined thereafter. After 6th decade, CVR in both frontal lobes, left parietal lobe and right basal ganglia decreased significantly with advancing age. There was no sexual difference of CVR. Quantitative assessment of CVR was possible by ACZ Tc-99m MHPAO brain SPECT. It revealed that rCBF and CVR changed according to age in normal Korean volunteers. There was no sexual difference

  16. Simultaneous acquisition of (99m)Tc- and (123)I-labeled radiotracers using a preclinical SPECT scanner with CZT detectors.

    Science.gov (United States)

    Kobayashi, Masato; Matsunari, Ichiro; Nishi, Kodai; Mizutani, Asuka; Miyazaki, Yoshiharu; Ogai, Kazuhiro; Sugama, Jyunko; Shiba, Kazuhiro; Kawai, Keiichi; Kinuya, Seigo

    2016-05-01

    Simultaneous acquisition of (99m)Tc and (123)I was evaluated using a preclinical SPECT scanner with cadmium zinc telluride (CZT)-based detectors. 10-ml cylindrical syringes contained about 37 MBq (99m)Tc-tetrofosmin ((99m)Tc-TF) or 37 MBq (123)I-15-(p-iodophenyl)-3R,S-methyl pentadecanoic acid ((123)I-BMIPP) were used to assess the relationship between these SPECT radioactive counts and radioactivity. Two 10-ml syringes contained 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP to assess the influence of (99m)Tc upscatter and (123)I downscatter, respectively. A rat-sized cylindrical phantom also contained both 100 or 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. The two 10-ml syringes and phantom were scanned using a pinhole collimator for rats. Myocardial infarction model rats were examined using 300 MBq (99m)Tc-TF and 100 MBq (123)I-BMIPP. Two 1-ml syringes contained 105 MBq (99m)Tc-labeled hexamethylpropyleneamine oxime ((99m)Tc-HMPAO) and 35 MBq (123)I-labeled N-ω-fluoropropyl-2β-carbomethoxy-3β-(4-iodophenyl) nortropane ((123)I-FP-CIT). The two 1-ml syringes were scanned using a pinhole collimator for mice. Normal mice were examined using 105 MBq (99m)Tc-HMPAO and 35 MBq (123)I-FP-CIT. The relationship between SPECT radioactive counts and radioactivity was excellent. Downscatter contamination of (123)I-BMIPP exhibited fewer radioactive counts for 300 MBq (99m)Tc-TF without scatter correction (SC) in 125-150 keV. There was no upscatter contamination of (99m)Tc-TF in 150-175 keV. In the rat-sized phantom, the radioactive count ratio decreased to 4.0 % for 300 MBq (99m)Tc-TF without SC in 125-150 keV. In the rats, myocardial images and radioactive counts of (99m)Tc-TF with the dual tracer were identical to those of the (99m)Tc-TF single injection. Downscatter contamination of (123)I-FP-CIT was 4.2 % without SC in 125-150 keV. In the first injection of (99m)Tc-HMPAO and second injection of (123)I-FP-CIT, brain images and radioactive counts

  17. Cerebral perfusion (HMPAO-SPECT) in patients with depression with cognitive impairment versus those with mild cognitive impairment and dementia of Alzheimer's type: a semiquantitative and automated evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Staffen, W.; Bergmann, J.; Schoenauer, U.; Kronbichler, M.; Golaszewski, S.; Ladurner, G. [Paracelsus Medical University, Christian-Doppler-Clinic, Department of Neurology, and Center of Cognitive Research Salzburg, Salzburg (Austria); Zauner, H. [Rehabilitation Center of the Pensionsversicherungsanstalt, Grossgmain (Austria)

    2009-05-15

    Comparative evaluation of regional brain perfusion measured by HMPAO-SPECT of patients with mild cognitive impairment (MCI), dementia of Alzheimer's type (DAT) and depression with cognitive impairment (DCI). A total of 736 patients were investigated because of suspected cognitive dysfunction. After exclusion of patients with other forms of dementia than DAT or relevant accompanying disorders, SPECT data from 149 MCI, 131 DAT and 127 DCI patients, and 123 controls without any cognitive impairment, were analysed. Relative cerebral blood flow of 34 anatomical regions was assessed with automated analysis software (BRASS). Calculation of global forebrain perfusion discriminated demented from nondemented patients. Compared to controls DCI patients showed hypoperfusion of the thalamus, lentiform nucleus and medial temporal cortex. MCI patients differed significantly from controls concerning perfusion in both hemispheric temporal and parietal areas, and in the (right hemispheric) posterior part of the cingulate gyrus. MCI and DCI patients differed in the parietal, temporal superior and right hemispheric cingulate gyrus posterior cortices. Global forebrain and regional perfusion was more extensively reduced in DAT patients and discriminated them from controls, and MCI and DCI patients. Frontal perfusion disturbance was only present in DAT patients. Automated analysis of HMPAO-SPECT data from MCI patients showed significant perfusion deficits in regions also involved in DAT patients, but ROC analysis demonstrated only moderate sensitivity and specificity for differentiating DAT patients from controls and DCI patients. Frontal hypoperfusion seems to correspond with conversion from MCI to DAT. Finally, the results in DCI patients again raise the question of depression as an early symptom of neurodegeneration. (orig.)

  18. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, Torbjoern; Riklund, Katrine Aa. [Umeaa University, Umeaa University Hospital, Department of Radiation Sciences, Diagnostic Radiology, Umeaa (Sweden); Elgh, Eva; Naesman, Birgitta [Umeaa University, Department of Community Medicine and Rehabilitation, Geriatric Medicine, Umeaa (Sweden); Larsson, Anne [Umeaa University, Department of Radiation Sciences, Radiation Physics, Umeaa (Sweden); Nyberg, Lars [Umeaa University, Department of Psychology, Umeaa (Sweden)

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2{+-}4.8 years) with mild AD and 18 healthy elderly (69.4{+-}3.9 years) were included in the study. The subjects were injected with{sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF{sup 99m}Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  19. The value of rCBF brain SPECT in assessing visual function of patients with honeymoons hemianopia

    International Nuclear Information System (INIS)

    Xie Ruiman; Yao Jingli; Qing Zheng

    1995-01-01

    Comparison of 99m Tc-HMPAO brain SPECT imaging of 8 cases with honeymoons hemianopia (HH) was taken before and after a course of oriented dynamic color photic stimulation (ODCPS). It was suggested that ODCPS in patients with HH was an effective method for increasing visual field and improving visual function. Cerebral metabolic patterns reflected the mechanism of ODCPS effecting the patients with HH. The retinal midbrain-occipital visual path-way may play an important role in mediating the increase of visual field and restoration of visual function. It was also concluded that brain SPECT imaging was an useful method for the studying of brain function

  20. SP-ECT imaging and its physical study

    International Nuclear Information System (INIS)

    Kinoshita, Fujimi

    1983-01-01

    Recently, more than a hundred hospitals are provided with SPECT system for clinical examination in Japan. However, a standardization of measuring method and performance test of the systems is ont yet made. We have been studying some basic problems of SPECT system with special phantoms originaly designed by ourselves. We got a conclusion that a standardized phantom is necessary for comparing performances between SPECT systems. In clinical experiences with 3,332 cases, we think that SPECT image combined with conventional image presents much more informations for accurate diagnosis, especially in brain, bone and tumor imagings. Synthesized image of SPECT and XCT, double tracer image and transmission image are useful to visualize the body contour and the clinical diagnosis. (author)

  1. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections

    Energy Technology Data Exchange (ETDEWEB)

    Erba, P.A. [University of Pisa, and University Hospital of Pisa, Regional Center of Nuclear Medicine, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); University of Pisa, Regional Center of Nuclear Medicine, Pisa (Italy); Leo, G. [ASL Lecce, U.O. Gestione Rapporti Convenzionali, U.O. Chirurgia Generale, Lecce, Pisa (Italy); University of Pisa, and University Hospital of Pisa, Division of Vascular Surgery, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); Sollini, M. [Az. Osp. S.Maria Nuova - IRCCS Reggio Emilia, Nuclear Medicine Unit, Department of Oncology and Advanced Technology, Reggio Emilia (Italy); Tascini, C.; Menichetti, F. [University Hospital of Pisa, Division of Infectious Diseases, Pisa (Italy); Boni, R.; Lazzeri, E.; Mariani, G. [University of Pisa, and University Hospital of Pisa, Regional Center of Nuclear Medicine, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy); Berchiolli, R.N.; Ferrari, M. [University of Pisa, and University Hospital of Pisa, Division of Vascular Surgery, Department of Translational Research and Advanced Technology in Medicine, Pisa (Italy)

    2014-02-15

    In this study we evaluated the diagnostic performance of {sup 99m}Tc-HMPAO-leucocyte ({sup 99m}Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. {sup 99m}Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37 % of patients (sensitivity and specificity 100 %, versus 85.1 % and 62.5 % for stand-alone SPECT). Sensitivity and specificity were 34 % and 75 % for US, 48.9 % and 83.3 % for CT, and 68.1 % and 62.5 % for the FitzGerald classification. Perioperative mortality was 5.5 %, mid-term mortality 12 %, and long-term mortality 27 %. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61 % versus 63 %, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3 % versus 45.5 %). {sup 99m}Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI

  2. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections.

    Science.gov (United States)

    Erba, P A; Leo, G; Sollini, M; Tascini, C; Boni, R; Berchiolli, R N; Menichetti, F; Ferrari, M; Lazzeri, E; Mariani, G

    2014-02-01

    In this study we evaluated the diagnostic performance of (99m)Tc-HMPAO-leucocyte ((99m)Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. (99m)Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37% of patients (sensitivity and specificity 100 %, versus 85.1% and 62.5% for stand-alone SPECT). Sensitivity and specificity were 34% and 75% for US, 48.9% and 83.3% for CT, and 68.1% and 62.5% for the FitzGerald classification. Perioperative mortality was 5.5%, mid-term mortality 12%, and long-term mortality 27%. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61% versus 63%, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3% versus 45.5%). (99m)Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive

  3. Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections

    International Nuclear Information System (INIS)

    Erba, P.A.; Leo, G.; Sollini, M.; Tascini, C.; Menichetti, F.; Boni, R.; Lazzeri, E.; Mariani, G.; Berchiolli, R.N.; Ferrari, M.

    2014-01-01

    In this study we evaluated the diagnostic performance of 99m Tc-HMPAO-leucocyte ( 99m Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. 99m Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37 % of patients (sensitivity and specificity 100 %, versus 85.1 % and 62.5 % for stand-alone SPECT). Sensitivity and specificity were 34 % and 75 % for US, 48.9 % and 83.3 % for CT, and 68.1 % and 62.5 % for the FitzGerald classification. Perioperative mortality was 5.5 %, mid-term mortality 12 %, and long-term mortality 27 %. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61 % versus 63 %, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3 % versus 45.5 %). 99m Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive

  4. Dose response from pharmacological interventions for CBF changes in a baboon model using 99Tcm-HMPAO and SPECT

    International Nuclear Information System (INIS)

    Dormehl, I.C.; Hugo, N.; Oliver, D.W.

    1993-01-01

    This study assesses the sensitivity of the baboon model under anaesthesia to determine by single photon emission computed tomography (SPECT) and 99 Tc m -hexamethylpropyleneamine oxime (HMPAO) dose responses from drugs (acetazolamide) with known regional cerebral blood flow (rCBF) effects on humans. Three dosages of acetazolamide were chosen: 250, 500 and 750 mg. The effects of these were studied by conventional SPECT 5 min after intravenous (i.v.) administration and compared to previous studies of rCBF with the baboons under anaesthesia only. An additional study concerned the effect of 500 mg acetazolamide at 15 min after administration. Haemodynamic parameters and blood gases were also monitored. No statistically significant regional effects were noted. The largest increase in CBF (39%) was observed from 500 mg acetazolamide after 5 min. This was statistically significantly different from control values only at a 10% level of confidence; then following a 27% increase above control values after 750 mg (5 min). At 15 min 500 mg yielded values lower by 10% than the high dose. No effects were observed from 250 mg acetazolamide; only pO 2 showed changes which largely confirm the CBF findings. The model did not give significant results at a 5% level of confidence but large fluctuations were observed, also in the haemodynamic and blood gas values. At a 10% level a significant dose response was confirmed for acetazolamide. (author)

  5. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    International Nuclear Information System (INIS)

    Sinnatamby, R.; Antoun, N.A.; Freer, C.E.L.; Miles, K.A.; Hodges, J.R.

    1996-01-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using 99m Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  6. Neuroradiological findings in primary progressive aphasia: CT, MRI and cerebral perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sinnatamby, R. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Antoun, N.A. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Freer, C.E.L. [Dept. of Radiology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Miles, K.A. [Dept. of Nuclear Medicine, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom); Hodges, J.R. [Dept. of Neurology, Addenbrooke`s Hospital NHS Trust, Cambridge (United Kingdom)

    1996-04-01

    Primary progressive aphasia (PPA) is defined as progressive decline in language for 2 or more years with preservation of activities of daily living and general cognitive functions. Whereas the clinical features of this syndrome have been well documented, the neuroradiological findings have not been studied systematically. We studied 13 patients with PPA retrospectively: 10 underwent CT, 12 MRI and 12 cerebral perfusion studies using {sup 99m}Tc-HMPAO SPECT. CT and MR images were scored for focal atrophy by two independent assessors. Initial qualitative assessment of SPECT images was confirmed by quantitative analysis. CY was normal in 5 patients. Focal atrophy, affecting predominantly the left temporal lobe, was seen in 4 of 10 patients on CT, and 10 of 12 on MRI. Atrophy was localised primarily to the superior and middle temporal gyri on MRI. All 12 patients who underwent SPECT had unilateral temporal lobe perfusion defects, in 2 patients of whom MRI was normal. CT is relatively insensitive to focal abnormalities in PPA; MRI and SPECT are the imaging modalities of choice. MRI allows accurate, specific localisation of atrophy with the temporal neocortex. SPECT may reveal a functional decrease in cerebral perfusion prior to establishment of structural change. (orig.)

  7. Clinical application of 99mTc-HMPAO labeled leucocytes imaging in detecting bone joint infection

    International Nuclear Information System (INIS)

    Li Biao; Barthe, N.; Basse-Cathalinat, B.

    1995-01-01

    99m Tc-MDP scintigraphy and 99m Tc-HMPAO-leucocytes imaging were performed in twenty five patients with clinically suspected bone joint infection. All of the 25 cases were confirmed by surgery, microbiological and histologic examinations. Among them 21 cases were definitively diagnosed as infections, while 3 cases were non-infection. The results of 99m Tc-MDP scintigraphy showed that all of 25 cases demonstrated anomalous accumulation of radioactivity in the clinically suspected infections sites, while in 99m Tc-HMPAO-leucocytes imaging, concentrated radioactivity in proved infectious sites was observed in 19 cases, non-anomalous radioactivity found in 4 cases of non-infectious sites, but there were 2 cases false negative with long term antibiotics treatment, none of the case was false positive. Thereby a sensitivity of the labelled leucocytes imaging of 90.5%, a specificity of 100%, and a accuracy of about 92% were found. Present research work concluded that 99m Tc-HMPAO labelled leucocytes imaging provided a non-invasive, effective, and reliable diagnostic method in detecting patients with clinically suspected bone joint infection and afforded strong evidence for effective therapy

  8. Cerebral blood flow assessed by brain SPECT with 99mTc-HMPAO utilising the acetazolamide test in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Lass, P.; Romanowicz, G.; Koseda-Dragan, M.

    1998-01-01

    Background: Cerebrovascular diseases are one of the most important complications of systemic lupus erythematosus (SLE). The diagnostic imaging of neuropsychiatric SLE complications presents many problems. This study was undertaken to investigate cerebral blood flow char s and its reactivity to hypercapnia by means of acetazolamide test in SLE patients. Methods: Brain SPECT studies using 99mTc-HMPAO were performed in 50 patients with SLE. Acetazolamide test was performed in 35 patients 3 days after the baseline study by means of repetitive scanning 20 min after i.v. injection of 1.0 g of acetazolamide. Results: Significant interhemispheric hypoperfusion areas were shown in 76.3% of all patients, 83.8% symptomatic and 63.1% asymptomatic. Patients with antiphospholipid syndrome showed multifocal perfusion deficits. The reaction of cerebral perfusion to acetazolamide was heterogenous and showed increase, decrease, no change or mixed reaction of baseline-study-found focal hypoperfusion. Acetazolamide test revealed hypoperfusion in two patients with normal baseline study. MRI scanning revealed cerebral lesions in 41% of patients. Conclusions: CBF asymmetries in symptomatic and asymptomatic patients with SLE are frequent. Regional CBF alterations seem to be different in patients with and without antiphospholipid syndrome. The part of the patients with SLE shows no or paradoxically inversed reaction to acetazolamide. (author)

  9. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  10. Relative hyperperfusion by SPECT in a family with a presenilin 1 (T245P) mutation.

    Science.gov (United States)

    Edwards-Lee, Terri; Wen, Johnny; Chung, Julia A; Vasinrapee, Panukorn; Mishkin, Frederick S

    2008-01-01

    Clinical characteristics of autosomal dominant Alzheimer's disease often differ clinically from sporadic disease with the onset of seizures, spasticity and myoclonus early in the disease course. Similarly imaging characteristics may also differ. We report the findings of relative hyperperfusion by Tc-99m HMPAO SPECT in the medial orbitofrontal cortex and anterior temporal lobe in four affected family members carrying a presenilin 1 mutation. SPECT of the four individuals was compared to an age-matched normal database. We speculate that the findings of relative medial orbitofrontal and anterior temporal lobe hyperperfusion may be a marker of early onset Alzheimer's disease in this family.

  11. Technetium-99m HMPAO brain SPECT in children with attention deficit hyperactivity disorder

    International Nuclear Information System (INIS)

    Kaya, G.C.; Pekcanlar, A.; Bekis, R.; Ada, E.; Miral, S.; Emiroglu, N.; Durak, H.

    2002-01-01

    Attention deficit hyperactivity disorder (ADHD) is a developmental, neurobehavioral syndrome with an onset in childhood. The aim of this study was to investigate the existence of regional perfusion changes in ADHD by means of Tc-99m HMPAO brain SPECT. Thirteen children with a diagnosis of ADHD and 7 healthy, age-matched controls were included in this study. Hypoperfusion was observed on the right temporal cortex in 9, and on the left temporal cortex in 3 children. The distribution of the lesions showed right lateral temporal cortex involvement in 3, right medial temporal cortex in 9 and left medial temporal cortex in 8 children. Asymmetric perfusion was seen on the caudate nucleus in 4, on the thalamus in 3 and on the frontal cortex in 6 children. There was a significant difference between children with ADHD and controls in right medial temporal cortex: cerebellum and right lateral temporal cortex: cerebellum ratios. Hypoperfusion in the right medial temporal cortex was significantly and inversely correlated with Du Paul teachers' questionnaire rating scale (r=-0.71, p=0.006). It has been postulated that difficulty in self regulating response to stimuli in ADHD is mediated by underfunctioning of the orbital frontal cortex and subsequent connection to the limbic system. Decreased temporal cortex perfusion may dysfunction of the limbic system or the orbito-frontal-limbic axis. (author)

  12. Technetium-99m HMPAO brain SPECT in children with attention deficit hyperactivity disorder

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, G.C.; Pekcanlar, A.; Bekis, R.; Ada, E.; Miral, S.; Emiroglu, N.; Durak, H. [Dokuz Eylul Univ., Izmir (Turkey). School of Medicine

    2002-12-01

    Attention deficit hyperactivity disorder (ADHD) is a developmental, neurobehavioral syndrome with an onset in childhood. The aim of this study was to investigate the existence of regional perfusion changes in ADHD by means of Tc-99m HMPAO brain SPECT. Thirteen children with a diagnosis of ADHD and 7 healthy, age-matched controls were included in this study. Hypoperfusion was observed on the right temporal cortex in 9, and on the left temporal cortex in 3 children. The distribution of the lesions showed right lateral temporal cortex involvement in 3, right medial temporal cortex in 9 and left medial temporal cortex in 8 children. Asymmetric perfusion was seen on the caudate nucleus in 4, on the thalamus in 3 and on the frontal cortex in 6 children. There was a significant difference between children with ADHD and controls in right medial temporal cortex: cerebellum and right lateral temporal cortex: cerebellum ratios. Hypoperfusion in the right medial temporal cortex was significantly and inversely correlated with Du Paul teachers' questionnaire rating scale (r=-0.71, p=0.006). It has been postulated that difficulty in self regulating response to stimuli in ADHD is mediated by underfunctioning of the orbital frontal cortex and subsequent connection to the limbic system. Decreased temporal cortex perfusion may dysfunction of the limbic system or the orbito-frontal-limbic axis. (author)

  13. Technetium-99m HMPAO brain SPECT in children with attention deficit hyperactivity disorder

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, G C; Pekcanlar, A; Bekis, R; Ada, E; Miral, S; Emiroglu, N; Durak, H [Dokuz Eylul Univ., Izmir (Turkey). School of Medicine

    2002-12-01

    Attention deficit hyperactivity disorder (ADHD) is a developmental, neurobehavioral syndrome with an onset in childhood. The aim of this study was to investigate the existence of regional perfusion changes in ADHD by means of Tc-99m HMPAO brain SPECT. Thirteen children with a diagnosis of ADHD and 7 healthy, age-matched controls were included in this study. Hypoperfusion was observed on the right temporal cortex in 9, and on the left temporal cortex in 3 children. The distribution of the lesions showed right lateral temporal cortex involvement in 3, right medial temporal cortex in 9 and left medial temporal cortex in 8 children. Asymmetric perfusion was seen on the caudate nucleus in 4, on the thalamus in 3 and on the frontal cortex in 6 children. There was a significant difference between children with ADHD and controls in right medial temporal cortex: cerebellum and right lateral temporal cortex: cerebellum ratios. Hypoperfusion in the right medial temporal cortex was significantly and inversely correlated with Du Paul teachers' questionnaire rating scale (r=-0.71, p=0.006). It has been postulated that difficulty in self regulating response to stimuli in ADHD is mediated by underfunctioning of the orbital frontal cortex and subsequent connection to the limbic system. Decreased temporal cortex perfusion may dysfunction of the limbic system or the orbito-frontal-limbic axis. (author)

  14. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  15. Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

    Science.gov (United States)

    Froeling, Vera; Heimann, Uwe; Huebner, Ralf-Harto; Kroencke, Thomas J; Maurer, Martin H; Doellinger, Felix; Geisel, Dominik; Hamm, Bernd; Brenner, Winfried; Schreiter, Nils F

    2015-07-01

    To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) × 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (ρ = 0.986) or ventilation (ρ = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.

  16. Pre-operative evaluation of medically intractable partial seizures using [sup 123]I-Iomazenil SPECT. Comparison with Video/EEG-monitoring and post-operative results. Praeoperative Bewertung pharmakoresistenter fokaler Epilepsien mit der [sup 123]J-Iomazenil-SPECT. Vergleich mit dem Video/EEG-Monitoring und postoperativen Ergebnissen

    Energy Technology Data Exchange (ETDEWEB)

    Venz, S [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Cordes, M [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Straub, H B [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Hierholzer, J [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Schroeder, R [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Richter, W [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Berlin (Germany); Schmitz, B [Strahlenklinik und Poliklinik und Neurologische Klinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, FU Ber

    1994-10-01

    SPECT with the benzodiazepine receptor antagonist [sup 123]I-Iomazenil was performed in 33 patients with intractable partial seizures for pre-operative evaluation. The results combined with MRI and [sup 99m]Tc-HMPAO-SPECT findings were compared with the video-assisted EEG monitoring (gold standard'') which localised the focus in 25 patients. 11 patients underwent surgical resection of the epileptogenic area and became seizure-free for a period up to 13 months. The lomazenil SPECT had a significantly higher sensitivity compared to [sup 99m]Tc-HMPAO in the visualization of an epileptogenic area and should be regularly used in the diagnostic of medically intractable partial seizures. (orig.)

  17. A comparison between dopamine transporters imaging and perfusion SPECT with HMPAO-99mTc in the diagnosis of dementia with Lewy bodies

    International Nuclear Information System (INIS)

    Voitota, J.B.; Emptaz, A.; Szurhaj, W.; Steinling, M.; Bombois, St.; Pasquier, F.

    2007-01-01

    Scintigraphic imaging of dementia relies today essentially on the study of brain single photo emission computed tomography (SPECT) perfusion, after intravenous injection of 99m Tc radiopharmaceutical. This paper is based on the guidelines published in October 2001 by the European Association of Nuclear medicine (http:// eanm.org). Dementia with Lewy bodies is the second cause of degenerative dementia. Differential diagnosis may be difficult, in spite of the emergence of standardized diagnostic criteria. Tomo-scintigraphy using iodine 123-labelled FP-CIT (DaTSCAN) could play a role in this process. Cerebral perfusion SPECT imaging is an important step of demented patient evaluation. We compared the diagnostic performance of both of these procedures in the diagnosis of dementia with Lewy bodies. We studied 15 patients; ten DaTSCAN and 14 cerebral perfusion studies were performed. Clinical diagnosis at the end of follow-up was established as the diagnostic reference. Cerebral perfusion SPECT showed a very low sensitivity (20%) and a good specificity (89%); considering a prevalence of dementia with Lewy bodies of 20%, positive predictive value (PPV) was 31% and negative predictive value (NPV) 82%. Performances of DaTSCAN tomo-scintigraphy were more encouraging, (sensitivity and specificity of 100%); predictive values are both of 100%. As a conclusion, DaTSCAN tomo-scintigraphy performs better than cerebral perfusion SPECT in the diagnosis of dementia with Lewy bodies and no conjoint or sequential use of those tests can be recommended. (authors)

  18. Development of 99mTc-labelled the d,1-diasteroisomer of HM-PAO for cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Lun Xiao.

    1989-10-01

    The d,1-diastereoisomer of hexamethyl propyleneamine oxime (HM-PAO) was selected as the preferred ligand for Tc-99m as a radiotracer for cerebral perfusion imaging. Further improvement of the synthesis and isolation method of HM-PAO resulted in pure d,1-HM-PAO and pure meso-HM-PAO. The neutral, lipophilic Tc-99m complexes of d,1-HM-PAO and meso-HM-PAO were formed in high yield by stannous reduction of Mo-99/Tc-99m generator eluate, respectively. Two minutes following i.v. administration of Tc-99m-d,1-HM-PAO in mice, 2.24% of the injected dose appears in the brain. Little washout of the tracer is observed up to 24-hour post injection. Two minutes following i.v. administration of Tc-99m-meso-HM-PAO in mice, 1.9% of the injected dose appears in the brain. The radioactivity of Tc-99m-meso-HM-PAO declined faster than that of Tc-99m-d,1-HM-PAO did in the brain up to 24-hour post injection. 12 refs, 5 figs, 5 tabs

  19. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  20. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  1. Comparison of D2 receptor binding (123I-IBZM) and rCBF (99mTc-HMPAO) in extrapyramidal disorders

    International Nuclear Information System (INIS)

    Saur, H.B.; Bartenstein, P.; Schober, O.; Oberwittler, C.; Lerch, H.; Masur, H.

    1994-01-01

    The aim of this SPECT study was to determine whether there is a correlation between rCBF ( 99m Tc-HMPAO) and D2 receptor binding ( 123 I-IBZM) in disorders of the extrapyramidal system and in which situation the 99 MTc-HMPAO scan could predict the outcome of the 123 I-IBZM study. 13 patients with Parkinson's syndrome and 13 patients with hyperkinetic extrapyramidal disorders were studied. In all patients the two SPECT studies were performed within 2-7 days. ROIs were placed over the basal ganglia (BG), the frontal cortex (FC) and the cerebellum (CE). The ratios BG/FC and BG/CE were calculated. In both groups the scatter was lower when the frontal cortex was used as reference region. Among the patients with hyperkinetic extrapyramidal hyperkinetic extrapyramidal disorders the two patients with Huntington's chorea had lower rCBF and D2 receptor binding compared to other hyperkinetic extrapyramidal disorders. There was no correlation between D2 receptor binding and rCBF in the basal ganglia. The 99 MTc-HMPAO studies did not provide clinically useful information, except in Huntington's chorea. (orig.) [de

  2. Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

    International Nuclear Information System (INIS)

    Negus, Ian S.; Holmes, Robin B.; Thorne, Gareth C.; Saunders, Margaret; Jordan, Kirsty C.; Nash, David A.

    2016-01-01

    Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding 99m Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for

  3. Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

    Energy Technology Data Exchange (ETDEWEB)

    Negus, Ian S.; Holmes, Robin B.; Thorne, Gareth C.; Saunders, Margaret [Department of Medical Physics and Bioengineering, University Hospitals Bristol NHS Foundation Trust, Bristol BS28HW (United Kingdom); Jordan, Kirsty C. [Department of Biomedical Engineering, University of Strathclyde, Glasgow G11XQ (United Kingdom); Nash, David A. [Department of Medical Physics, Portsmouth Hospitals NHS Trust, Portsmouth PO63LY (United Kingdom)

    2016-09-15

    Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable

  4. Clinical assessment of SPECT/CT co-registration image fusion

    International Nuclear Information System (INIS)

    Zhou Wen; Luan Zhaosheng; Peng Yong

    2004-01-01

    Objective: Study the methodology of the SPECT/CT co-registration image fusion, and Assessment the Clinical application value. Method: 172 patients who underwent SPECT/CT image fusion during 2001-2003 were studied, 119 men, 53 women. 51 patients underwent 18FDG image +CT, 26 patients underwent 99m Tc-RBC Liver pool image +CT, 43 patients underwent 99mTc-MDP Bone image +CT, 18 patients underwent 99m Tc-MAA Lung perfusion image +CT. The machine is Millium VG SPECT of GE Company. All patients have been taken three steps image: X-ray survey, X-ray transmission and nuclear emission image (Including planer imaging, SPECT or 18 F-FDG of dual head camera) without changing the position of the patients. We reconstruct the emission image with X-ray map and do reconstruction, 18FDG with COSEM and 99mTc with OSEM. Then combine the transmission image and the reconstructed emission image. We use different process parameters in deferent image methods. The accurate rate of SPECT/CT image fusion were statistics, and compare their accurate with that of single nuclear emission image. Results: The nuclear image which have been reconstructed by X-ray attenuation and OSEM are apparent better than pre-reconstructed. The post-reconstructed emission images have no scatter lines around the organs. The outline between different issues is more clear than before. The validity of All post-reconstructed images is better than pre-reconstructed. SPECT/CT image fusion make localization have worthy bases. 138 patients, the accuracy of SPECT/CT image fusion is 91.3% (126/138), whereas 60(88.2%) were found through SPECT/CT image fusion, There are significant difference between them(P 99m Tc- RBC-SPECT +CT image fusion, but 21 of them were inspected by emission image. In BONE 99m Tc -MDP-SPECT +CT image fusion, 4 patients' removed bone(1-6 months after surgery) and their relay with normal bone had activity, their morphologic and density in CT were different from normal bones. 11 of 20 patients who could

  5. 99mTc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    International Nuclear Information System (INIS)

    Yang, Hyung In; Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon

    1994-01-01

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  6. Follow-up findings in regional cerebral blood flow (r-CBF)-SPECT in a case of idiopathic childhood hemidystonia. Functional neuroimaging and pathophysiological implications

    International Nuclear Information System (INIS)

    Fiedler, A.; Aderbauer, J.; Segerer, H.; Marienhagen, J.; Bock, E.; Eilles, C.

    1999-01-01

    A 9 1/2-year-old girl suffered from intermitting tremor and jitteriness of her left hand and oral muscles every 4 to 6 weeks with long lasting episodes. Clinically myoclonias and dystonic positioning of the left arm, hand and facial muscles were seen. No evidence of trauma, infection or inborn errors of metabolism was found. Successful therapy with carbamazepine was initiated while L-DOPA failed. An ictal 99m-Tc-HMPAO-SPECT showed severe asymmetry with focal hyperperfusion of the contralateral right thalamus and basal ganglia as well as of the bifrontal cortex, whereas no anatomical lesions were found by MRI. In contrast, an interictally performed 99m-Tc-HMPAO SPECT showed hypoperfusion or the right thalamus and normalisation of the frontal perfusion under medical treatment. These 99m-Tc-HMPAO-SPECT findings may provide new insights into the localisation and pathophysiological pathways of idiopathic childhood dystonia. (orig.) [de

  7. Differences at brain SPECT between depressed females with and without adult ADHD and healthy controls: etiological considerations

    Directory of Open Access Journals (Sweden)

    Jacobsson Hans

    2009-09-01

    Full Text Available Abstract Background Comorbidity between Attention Deficit Hyperactivity Disorder (ADHD and mood disorders is common. Alterations of the cerebellum and frontal regions have been reported in neuro-imaging studies of ADHD and major depression. Methods Thirty chronically depressed adult females of whom 16 had scores below, and 14 scores above, cut-offs on the 25-items Wender Utah Retrospective Scale (WURS-25 and the Wender-Reimherr Adult Attention Deficit Disorder Scale (WRAADDS were divided into subgroups designated "Depression" and "Depression + ADHD", respectively. Twenty-one of the patients had some audiological symptom, tinnitus and/or hearing impairment. The patients were investigated with other rating scales and 99mTc-HMPAO SPECT. Controls for 99mTc-HMPAO SPECT were 16 healthy females. SPECT was analyzed by both statistical parametric mapping (SPM2 and the computerized brain atlas (CBA. Discriminant analysis was performed on the volumes of interest generated by the CBA, and on the scores from rating scales with the highest group differences. Results The mean score of a depression rating scale (MADRS-S was significantly lower in the "Depression" subgroup compared to in the "Depression + ADHD" subgroup. There was significantly decreased tracer uptake within the bilateral cerebellum at both SPM and CBA in the "Depression + ADHD" subgroup compared to in the controls. No decrease of cerebellar tracer uptake was observed in "Depression". Significantly increased tracer uptake was found at SPM within some bilateral frontal regions (Brodmann areas 8, 9, 10, 32 in the "Depression + ADHD" subgroup compared to in "Depression". An accuracy of 100% was obtained for the discrimination between the patient groups when thalamic uptake was used in the analysis along with scores from Socialization and Impulsivity scales. Conclusion The findings confirm the previous observation of a cerebellar involvement in ADHD. Higher bilateral frontal 99mTc-HMPAO uptake in

  8. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  9. The role of brain SPECT in children with epilepsy

    International Nuclear Information System (INIS)

    Liu Xingdang; Liu Yongchang; Lin Xiangtong

    1996-01-01

    The rCBF brain SPECT with 99m Tc-HMPAO was performed in 15 children with interictal epilepsy, and some cases were compared with EEG, X-ray CT and MRI. The results showed that the positive rate of SPECT was the highest (93.33%,), then the EEG (92.31%), and the CT and MRI were the lowest (66.67% and 75%). This study indicated that brain SPECT was an effective method for diagnosis and foci localization in epileptic children, and also was useful to the study of prognosis and relationship between changes of rCBF and progress in clinical pictures

  10. A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT

    International Nuclear Information System (INIS)

    Qian Jianguo; Bradley, Eric L.; Majewski, Stan; Popov, Vladimir; Saha, Margaret S.; Smith, Mark F.; Weisenberger, Andrew G.; Welsh, Robert E.

    2008-01-01

    We have designed and built a small-animal single-photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole collimators suitable for imaging the ∼35 keV photons from the decay of 125 I have been built and installed to achieve useful spatial resolution over a range of object-detector distances and to reduce imaging time on our dual-detector array. To address the resolution limitations in the parallel-hole SPECT and the sensitivity and limited field of view of single-pinhole SPECT, we have incorporated multipinhole circular and helical SPECT in addition to expanding the parallel-hole SPECT capabilities. The pinhole SPECT system is based on a 110 mm diameter circular detector equipped with a pixellated NaI(Tl) scintillator array (1x1x5 mm 3 /pixel). The helical trajectory is accomplished by two stepping motors controlling the rotation of the detector-support gantry and displacement of the animal bed along the axis of rotation of the gantry. Results obtained in SPECT studies of various phantoms show an enlarged field of view, very good resolution and improved sensitivity using multipinhole circular or helical SPECT. Collimators with one, three and five, 1-mm-diameter pinholes have been implemented and compared in these tests. Our objective is to develop a system on which one may readily select a suitable mode of either parallel-hole SPECT or pinhole circular or helical SPECT for a variety of small animal imaging applications

  11. Regional cerebral blood flow studies with single photon emission computed tomography (SPECT); Clinical experiences, possibilities. Regionalis agyi veratfolyas vizsgalata egyfotonos emissios computer tomographiaval (SPECT); Klinikai tapasztalatok, lehetoesegek

    Energy Technology Data Exchange (ETDEWEB)

    Pavics, Laszlo; Csernay, Laszlo; Doczi, Tamas; Lang, Jenoe; Blaho, Gabor; Janka, Zoltan; Bodosi, Mihaly [Szegedi Orvostudomanyi Egyetem, Szeged (Hungary)

    1990-01-07

    Clinical experiences based on regional cerebral blood flow investigations with {sup 99m}Tc hexamethylpropyleneamin-oxime (HMPAO) SPECT in 164 patients are reported. The pharmacokinetics of the {sup 99m}Tc HMPAO are summarized, and the important indications of the investigations are interpreted in case reports (stroke, surgical solution of intracavernous aneurysm, Alzheimer and multiinfarct types of dementia). The literature data suggest that the diagnostic possibilities with this method are advantageous, even in other diseases. (author) 36 refs.; 7 figs.

  12. SPECT data acquisition and image reconstruction in a stationary small animal SPECT/MRI system

    Science.gov (United States)

    Xu, Jingyan; Chen, Si; Yu, Jianhua; Meier, Dirk; Wagenaar, Douglas J.; Patt, Bradley E.; Tsui, Benjamin M. W.

    2010-04-01

    The goal of the study was to investigate data acquisition strategies and image reconstruction methods for a stationary SPECT insert that can operate inside an MRI scanner with a 12 cm bore diameter for simultaneous SPECT/MRI imaging of small animals. The SPECT insert consists of 3 octagonal rings of 8 MR-compatible CZT detectors per ring surrounding a multi-pinhole (MPH) collimator sleeve. Each pinhole is constructed to project the field-of-view (FOV) to one CZT detector. All 24 pinholes are focused to a cylindrical FOV of 25 mm in diameter and 34 mm in length. The data acquisition strategies we evaluated were optional collimator rotations to improve tomographic sampling; and the image reconstruction methods were iterative ML-EM with and without compensation for the geometric response function (GRF) of the MPH collimator. For this purpose, we developed an analytic simulator that calculates the system matrix with the GRF models of the MPH collimator. The simulator was used to generate projection data of a digital rod phantom with pinhole aperture sizes of 1 mm and 2 mm and with different collimator rotation patterns. Iterative ML-EM reconstruction with and without GRF compensation were used to reconstruct the projection data from the central ring of 8 detectors only, and from all 24 detectors. Our results indicated that without GRF compensation and at the default design of 24 projection views, the reconstructed images had significant artifacts. Accurate GRF compensation substantially improved the reconstructed image resolution and reduced image artifacts. With accurate GRF compensation, useful reconstructed images can be obtained using 24 projection views only. This last finding potentially enables dynamic SPECT (and/or MRI) studies in small animals, one of many possible application areas of the SPECT/MRI system. Further research efforts are warranted including experimentally measuring the system matrix for improved geometrical accuracy, incorporating the co

  13. SPECT imaging with resolution recovery

    International Nuclear Information System (INIS)

    Bronnikov, A. V.

    2011-01-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  14. Brain SPECT in the pre-surgical evaluation of epileptic patients

    International Nuclear Information System (INIS)

    Buchpiguel, C.A.; Cukiert, A.; Hironaka, F.H.; Cerri, G.G.; Magalhaes, A.E.A.; Marino Junior, R.

    1992-01-01

    Fifteen adult epileptic patients were studied pre-operatively using a rotational scintillation camera interfaced to a dedicated computer. The tomographic images were obtained 15 minutes after intravenous injection of 99 m Tc-HMPAO. All had MRI scanning and intensive EEG monitoring which generally included seizure recording. Five patients had progressive lesions (3 meningiomas, 2 astrocytomas). In 10 patients, neuroradiological studies did not show the presence of progressive lesions (2 normal scans and 8 cases with inactive lesions). Two patients with meningioma showed hypoperfusion at the lesion site while the third patient had a marked hypoperfusion which might correlate with the clinical diagnosis of epilepsia partialis continua. In the astrocytoma patients SPECT scans showed hypoperfusion at the lesion site. Data obtained from the 10 patients without progressive CNS lesions showed: in 4, SPECT findings correlated well with the anatomical findings; in 5 instances, SPECT was able to disclose additional functional deficits; in one case, there was no SPECT correlate of a discrete anatomical lesion. In 5 of these cases with no progressive lesions (n=10) SPECT findings were useful as a complementary tool in determining the clinical or surgical management of these patients. Despite the small number and heterogeneity of the present sample, SPECT seems to be an useful tool as part of the clinical workup of epileptic who are candidates for epilepsy surgery. (author)

  15. Tc-99m HMPAO brain uptake patterns in patients with dementia of Alzheimer type

    International Nuclear Information System (INIS)

    Costa, D.C.; Burns, A.; Philpot, M.; Levy, R.; Ell, P.J.

    1988-01-01

    Conventional gamma camera SPECT with Tc-99m HMPAO (10 MBq/kg patient weight) was carried out in 21 patients with dementia of Alzheimer type (DAT), fulfilling the criteria established by the National Institute of Neurological and Communicative Disorders and Stroke and the ADRDA criteria (nine with amnesia as the main symptom [group 1], 12 with amnesia, aphasia, and/or apraxia and agnosia [group 2], and eight age-matched control subjects. Perfusion was quantitatively studied by means of cerebrum-cerebellum activity ratios. In group 1, perfusion deficits in the mesial cortex of the temporal lobes (right, 0.70; left, 0.68) were found, and ratios were significantly lower than in the control group (right, 0.77; left, 0.76 [P < .05]). Group 2 showed low ratios throughout both temporal lobes (mesial and lateral cortex), bilaterally in the posterior parietal cortex (right, 0.69; left, 0.66 [control: right, 0.80; left, 0.81] [P < .001]), and left frontal cortex (0.75 [control, 0.79] [P < .05]). In conclusion, SPECT with Tc-99m HMPAO identifies perfusion deficits in patients with DAT, and these correlate well with the clinical findings and are significantly different from those in the control group

  16. Technical approach to improvement of SPECT images

    International Nuclear Information System (INIS)

    Fukukita, Hiroyoshi

    1985-01-01

    At present, a large number of SPECT systems are being widely used in Japan, hence, it is reasonable for us to know the physical and imaging characteristics of these SPECT devices, and also to recommend the optimum utility of SPECT systems. For this reason, a survey respect of characteristics of the commercialy available SPECT devices was carried out. In addition to this, various factors which have significant influence over SPECT image quality, such as, data acquisition matrix, reconstruction filter, γ-ray attenuation correction and daily quality control procedure, were also investigated. The materials used for this study are PET/SPECT phantom, Alderson liver phantom filled with Tc-99m solution, and either LFOV-E or ZLC-7500 interfaced to Scintipac 2400 minicomputer with 256 K byte of memory. Following are the results of this study. 1) The suitable data acquisition procedure was 128 x 128 matrix for linear sampling and approximately 64 views for angular sampling. 2) Reconstructed image using pre-processing filter with Wiener and Butterworth filters provided high quality image as compared with the Ramp filter. 3) Weighted backprojection method (WBP) proposed by Tanaka was superior to other methods, such as Sorenson method and Chang method in the object with non-uniform distribution of radionuclide. 4) It was found that uniformity correction of gamma camera and precise adjustment of the center of rotation are most important to maintain the images with a high quality. (author)

  17. {sup 99m}Tc-HMPAO Brain SPECT in Seizure Disorder: Comparison Brain SPECT, MRI / CT and EEG

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hyung In [Kyunghee University Hospital, Seoul (Korea, Republic of); Im, Ju Hyuk; Choi, Chang Woon; Lee, Dong Soo; Chung, June Key; No, Jae Kyu; Lee, Myung Chul; Koh, Chang Soon [Seoul National University Hospital, Seoul (Korea, Republic of)

    1994-03-15

    We studied 115 patients with seizure who had been performed brain SPECT brain MRI of CT and EEG. To evaluate the pattern of brain SPECT in seizure patients 28 of them had secondary epilepsies, 87 had primary epilepsies. In primary epilepsies, 42 were generalized seizure and 45 were partial seizure. The causes of secondary epilepsies were congenital malformation, cerebromalacia, cerebral infarction ultiple sclerosis, AV-malformation. granuloma and etc, in order. In 28 secondary epilepsies, 25 of them, brain SPECT lesions was concordant with MRI or CT lesions. 3 were disconcordant. The brain SPECT findings of generalized seizure were normal in 22 patients, diffuse irregular decreased perfusion in 8, decreased in frontal cortex in 4. temporal in 5 and frontotemporal in 3. In 45 partial seizure, 19 brain SPECT were concordant with EEG (42.4%).

  18. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  19. The clinical use of brain SPECT imaging in neuropsychiatry

    International Nuclear Information System (INIS)

    Amen, Daniel G; Wu, Joseph C; Carmichael, Blake

    2003-01-01

    This article reviews the literature on brain SPECT imaging in brain trauma, dementia, and temporal lobe epilepsy. Brain SPECT allows clinicians the ability to view cerebral areas of healthy, low, and excessive perfusion. This information can be correlated with what is known about the function or dysfunction of each area. SPECT has a number of advantages over other imaging techniques, including wider availability, lower cost, and high quality resolution with multi-headed cameras. There are a number of issues that compromise the effective use of SPECT, including low quality of some imaging cameras, and variability of image rendering and readings (Au)

  20. Evaluation of cerebral vasoreactivity by SPECT and transcranial doppler sonography using the acetazolamide test

    Energy Technology Data Exchange (ETDEWEB)

    Pavics, L. [Dept. of Nuclear Medicine, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Gruenwald, F. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin; Barzo, P. [Dept. of Neurosurgery, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Ambrus, E. [Dept. of Nuclear Medicine, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Menzel, C. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin; Schomburg, A. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin; Borda, L. [Dept. of Neurosurgery, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Mate, E. [Laszlo Kalmar Kibernetic Lab., Attila Jozsef Univ., Szeged (Hungary); Bodosi, M. [Dept. of Neurosurgery, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Csernay, L. [Dept. of Nuclear Medicine, Albert Szent-Gyoergyi Medical Univ., Szeged (Hungary); Biersack, H.J. [Bonn Univ. (Germany). Abt. fuer Nuklearmedizin

    1994-12-01

    rCBF SPECT with {sup 99m}Tc-HMPAO was performed prospectively in 29 patients (3 controls and 26 stroke patients) as well as TCD studies in 20 patients (3 controls and 17 stroke patients) before and after 1 g i.v. acetazolamide. The sensitivity of rCBF SPECT increased from 62% to 77% after acetazolamide provocation in stroke patients. In patients with a reversible neurological deficit, the sensitivity under resting conditions was 50% which increased to 71%, while in cases with a permanent deficit it increased from 75% to 83%. In the evaluation of the cerebrovascular reserve capacity the results of rCBF SPECT and TCD coincided in 91% of the hemispheres. The correlation was statistically significant. (orig.) [Deutsch] Bei 29 Patienten (3 Kontrollpersonen, 26 Patienten mit zerebrovaskulaerer Erkrankung) wurde prospektiv die Hirn-SPECT mit {sup 99m}TC-HMPAO und bei 20 Patienten (3 Kontrollpersonen, 17 Patienten mit ZVK) die transkranielle Dopplersonographie (TCD) vor und nach i.v. Gabe von Azetazolamid durchgefuehrt. Die Sensitivitaet der Hirn-SPECT erhoehte sich mit Azetazolamid von 62% auf 77%. Bei Patienten mit reversiblem neurologischem Defizit wurde eine Verbesserung von 50% auf 71%, bei Patienten mit persistierendem Defizit von 75% auf 83% beobachtet. Die Ergebnisse der Hirn-SPECT und der TCD stimmten in der Beurteilung der zerebrovaskulaeren Reservekapazitaet in 91% der Hemisphaeren ueberein. Die Korrelation zwischen den beiden Methoden war statistisch signifikant. (orig.)

  1. Cerebral SPECT, a new diagnostic marker in depression

    International Nuclear Information System (INIS)

    Galli, Enrique

    2001-01-01

    Over the past twenty years the functional brain imagenology has improved greatly. Today the diagnostic, prognostic and therapeutic response are possible in psychiatry and neurology. The functional denomination in psychiatry has been known for more than a 100 years and it can be evident in the brain images. The relation between the blood brain flux and the brain can be seen as pictures in the Brain SPECT as hyper and hypo function areas. To carry out SPECT a venous injection of Tc-99m Technetium and (HMPAO) or (ECD) is applied in the arm. The images correspond to a period of two minutes after injection. The exam can be done until six hours after the brain fixation. The study is carried out in conditions, with the patient in repose, relaxed and without medication. The final result is an brain in colors. The yellow color gives us 95% of decrease and white color 95% of increase of the brain function. The red color gives a normal perfusion. The object of the study is to find that the Brain SPECT could be used as a new diagnostic marker of depression. The sample was 73 outpatients with major depression Our diagnostic marker is the prefrontal cortex ventral hypoperfusion (orbit frontal) in almost 100% of the patients and only 32% dorsal hypoperfusion (executive area), unlike most authors (Au)

  2. Evaluating acute effects of Electro Convulsive Therapy (ECT) on brain perfusion with Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Ozguven, M.; Ozturk, E.; Gunalp, B.; Ozgen, F.; Bayhan, H.

    1992-01-01

    Regional cerebral blood flow (rCBF) was measured by Tc-99m HMPAO brain perfusion SPECT in 10 schizophrenes (8 male, 2 female) undergoing electro convulsive therapy (ECT) and the results were compared to those of baseline studies performed 3 days prior to the ECT application to evaluate its acute effect on brain perfusion. ECT caused a redistribution in the tracers uptake. There was a global increase in the rCBF and the uptake became more pronounced in the basal ganglia (left: 44.4+-1.9%, right: 43.1+-19%) and to a degree in the parietal (left: 26.5+-4.1%, right: 25+-3.4%) and temporal (left: 22.9+-4.3%, right: 22.3+-3.6%) cortices. When evaluating the effects of ECT on rCBF, factors like the used perfusion agent, the injection and rCBF measurement times, clinical status of the patient, duration of the illness, used therapeutic agents and variations in the ECT application should be taken into consideration because the obtained data may reflect either the ictal or post-ictal changes on rCBF and is specific to the group of patients undergoing the study

  3. Utility of Brain SPECT 99mTc-HMPAO scintigraphy for the evaluation of regional cerebral blood flow changes in patients suffering from dissociative amnesia DA and dissociative motor disorders DMD (previously termed as hysteria)

    International Nuclear Information System (INIS)

    Ali, F.

    2007-01-01

    Full text: The aim of the study was to assess the utility of Brain SPECT 99 mTc-HMPAO scintigraphy for the evaluation of regional cerebral blood flow changes in patients suffering from dissociative amnesia (DA) and dissociative motor disorders (DMD) (previously termed as Hysteria). Materials and Methods: 20 patients were included in the study with a mean age of 26 years, 08 of them suffering from DA and 12 from DMDs. A consultant psychiatrist on the basis of ICD-10 criteria made the diagnosis. Patients were divided into two categories according to the duration of their illness. Category A; included 10 patients having less than six months duration of illness. Category B; included 10 patients having duration of illness more than six months. Ten normal controls having no signs and symptoms of any psychiatric disorder were also included in the study. Brain SPECT study was carried out using 99 mTc-HMPAO. Semiquantitative analysis was done by calculating cortical and cerebellar ratios in normals and comparing the same in the patients. Results: By comparing regional cerebral blood flow ratios of both the categories with normal group, patients suffering from DA showed hypoperfusion in bilateral temporal lobes, in both frontal association areas and both orbito frontal regions and patients suffering for more than 06 months showed a slightly more exaggerated pattern of hypoperfusion in the same cortical areas. On the other hand in DMD only the patients suffering for more than 06 months showed altered cerebral blood perfusion like hypoperfusion in both of the frontal motor areas, hypoperfusion in both temporal lobes and marked hyperperfusion in both orbito frontal areas. Conclusion: Patients of DA show abnormal cerebral perfusion pattern whether in acute or chronic stage while only chronic DMD states precipitate altered cerebral perfusion patterns and these can be visualized on a Brain SPECT study. (author)

  4. Stereotactic radiosurgery planning with ictal SPECT images

    International Nuclear Information System (INIS)

    Ackerly, T.; RMIT University, Bundoora, VIC; Geso, M.; O'Keefe, G.; Smith, R.

    2004-01-01

    This paper is motivated by a clinical requirement to utilise ictal SPECT images for target localisation in stereotactic radiosurgery treatment planning using the xknife system which only supports CT and MRI images. To achieve this, the SPECT images were converted from raw (pixel data only) format into a part 10 compliant DICOM CT fileset. The minimum requirements for the recasting of a raw format image as DICOM CT or MRI data set are described in detail. The method can be applied to the importation of raw format images into any radiotherapy treatment planning system that supports CT or MRI import. It is demonstrated that the combination of the low spatial resolution SPECT images, depicting functional information, with high spatial resolution MRI images, which show the structural information, is suitable for stereotactic radiosurgery treatment planning. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  5. Study on SPECT image for children with cerebral infarction

    International Nuclear Information System (INIS)

    Xie Wenhuang; Xie Zhichun; Chen Yucai; Lin Haoxue; Zheng Aidong; Xie Hui

    1998-01-01

    To explore the diagnostic value of SPECT image for children with cerebral infarction (CCI), comparative research was made on 26 cases undergoing regional cerebral perfusion (rCP) image between SPECT imaging and CT scanning. The results showed that the rCP in the infarct and its distant area was decreased. The positive rate of SPECT and CT were 92.3% (24/26) and 84.5% (22/26) respectively. The difference was not significant (P = 0.67, P>0.05). But, the positive rate of SPECT image 2 days after onset in 9 CCI was 100% (9/9), significantly higher than 55.6% (5/9) in CT scanning (P = 0.04, P<0.05). These findings suggested that the SPECT imaging is a sensitive method for the early diagnosis of CCI, and also helpful for observation of the therapeutic effect and evaluation of the prognosis

  6. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    Science.gov (United States)

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  7. Diagnosis of functional loss using with PET or SPECT

    International Nuclear Information System (INIS)

    Maeda, Tetsuya; Nagata, Ken

    2009-01-01

    Described are outlines of positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging, and their application to diagnosis of brain diseases accompanying functional loss. PET imaging by annihilation photons is useful to see the brain metabolic activity with use of compounds labeled by positron emitters like 11 C, 15 O, 13 N and 18 F. Cerebral blood flow (CBF), CB volume and oxygen extraction fraction correlate well with the cerebral activity and can be measured by PET with C 15 O 2 , H 2 15 O or 15 O 2 . 18 F-glucose is usable to measure the cerebral metabolic rate of glucose. SPECT imaging by γ-rays of 133 Xe, 123 I-iofetamine (IMP), 99m Tc-hexamethyl propylene amine oxime (HMPAO) and 99m Tc-ethyl cysteinate dimer (ECD) is useful also to measure CBF in different mechanisms from agent to agent, which often reflect the pathophysiology of the lesion in problem. These imaging techniques are applied to the diagnosis of regional functional loss in ischemic brain diseases like infarction, dementia (Alzheimer and multiple vascular) and Parkinsonism, of which characters and details of actual images are presented herein. Authors say that although the imaging diagnosis for brain functional loss has progressed, the integration of neurological finding, clinical process and simple morphological brain image as well is still important in the routine examination. (K.T.)

  8. SPECT-imaging of activity-dependent changes in regional cerebral blood flow induced by electrical and optogenetic self-stimulation in mice.

    Science.gov (United States)

    Kolodziej, Angela; Lippert, Michael; Angenstein, Frank; Neubert, Jenni; Pethe, Annette; Grosser, Oliver S; Amthauer, Holger; Schroeder, Ulrich H; Reymann, Klaus G; Scheich, Henning; Ohl, Frank W; Goldschmidt, Jürgen

    2014-12-01

    Electrical and optogenetic methods for brain stimulation are widely used in rodents for manipulating behavior and analyzing functional connectivities in neuronal circuits. High-resolution in vivo imaging of the global, brain-wide, activation patterns induced by these stimulations has remained challenging, in particular in awake behaving mice. We here mapped brain activation patterns in awake, intracranially self-stimulating mice using a novel protocol for single-photon emission computed tomography (SPECT) imaging of regional cerebral blood flow (rCBF). Mice were implanted with either electrodes for electrical stimulation of the medial forebrain bundle (mfb-microstim) or with optical fibers for blue-light stimulation of channelrhodopsin-2 expressing neurons in the ventral tegmental area (vta-optostim). After training for self-stimulation by current or light application, respectively, mice were implanted with jugular vein catheters and intravenously injected with the flow tracer 99m-technetium hexamethylpropyleneamine oxime (99mTc-HMPAO) during seven to ten minutes of intracranial self-stimulation or ongoing behavior without stimulation. The 99mTc-brain distributions were mapped in anesthetized animals after stimulation using multipinhole SPECT. Upon self-stimulation rCBF strongly increased at the electrode tip in mfb-microstim mice. In vta-optostim mice peak activations were found outside the stimulation site. Partly overlapping brain-wide networks of activations and deactivations were found in both groups. When testing all self-stimulating mice against all controls highly significant activations were found in the rostromedial nucleus accumbens shell. SPECT-imaging of rCBF using intravenous tracer-injection during ongoing behavior is a new tool for imaging regional brain activation patterns in awake behaving rodents providing higher spatial and temporal resolutions than 18F-2-fluoro-2-dexoyglucose positron emission tomography. Copyright © 2014 The Authors

  9. Scintigraphic assessment of cerebral blood flow changes in chrongic tobacco users using Tc-99m HMPAO brain SPECT

    International Nuclear Information System (INIS)

    Saeed, S.; Raza, M.; Sohaib, M.

    2004-01-01

    HMPAO SPECT is a useful and readily available method for estimation of rCBE This study aimed at defining a correlation between chronic tobacco use and changes in cerebral blood flow, through visual and semi-quantitative scintigraphic assessment, rCBF in 48 chronic tobacco users and 11 quitters was evaluated, utilising a normal database created by HMPAO brain scans of 20 non-smokers. Subjects were classified into chronic tobacco users and non-tobacco users through the smoking index (SI). SI value of 100 was taken as the cut-off value. Tobacco users who had discontinued tobacco use for three months or more were classified as 'Quitters'. ROIs were declared hypo- or hyper-perfused if their percentage perfusion values relative to the average perfusion per pixel of the whole slice did not fall within + 2 SD of the mean regional perfusion in the corresponding ROI, in the normal control group.rCBF in chronic tobacco users was found to be far less than the non-tobacco users (P < 0.001). The quitters showed significantly better cerebral perfusion compared to the chronic tobacco users (P < 0.025) but their rCBF was still significantly decreased relative to the non-tobacco users (P < 0.005). In chronic tobacco users, the rCBF was decreased in parietal (P < 0.05) and occipital (P < 0.005) regions of the cortex, and increased in the temporal cortex (P < 0.001). The frontal cortex showed both hyperperfusion (P < 0.001) and hypoperfusion (P < 0.025), perhaps due to varying perfusion patterns in different areas / sub-regions of the frontal cortex. The cerebellar blood flow in chronic tobacco users was much decreased compared to the normal controls (P < 0.001).Generally, a satisfactory correlation between the results obtained visually and semi-quantitatively was found. Semi-quantitative approach, however, appeared better specially when regional radiotracer uptake (actual acquired average regional counts) were used as an adjunct to support the findings. (authors)

  10. Brain imaging during seizure: ictal brain SPECT

    International Nuclear Information System (INIS)

    Kottamasu, Sambasiva Rao

    1997-01-01

    The role of single photon computed tomography (SPECT) in presurgical localization of medically intractable complex partial epilepsy (CPE) in children is reviewed. 99m Technetium neurolite, a newer lipophylic agent with a high first pass brain extraction and little or no redistribution is injected during a seizure, while the child is monitored with a video recording and continuous EEG and SPECT imaging is performed in the next 1-3 hours with the images representing regional cerebral profusion at the time of injection. On SPECT studies performed with radiopharmaceutical injected during a seizure, ictal focus is generally hypervascular. Other findings on ictal brain SPECT include hypoperfusion of adjacent cerebral cortex and white matter, hyperperfusion of contralateral motor cortex, hyperperfusion of ipsilateral basal ganglia and thalamus, brain stem and contralateral cerebellum. Ictal brain SPECT is non-invasive, cost effective and highly sensitive for localization of epileptic focus in patients with intractable CPE. (author)

  11. 99mTc-HMPAO-labelled leucocyte scintigraphy in the diagnosis of infection after total knee replacement arthroplasty

    International Nuclear Information System (INIS)

    Park, Dong Rib; Kim, Jae Seung; Ryu, Jin Sook; Moon, Dae Hyuk; Bin, Seong Il; Cho, Woo Shin; Lee, Hee Kyung

    1999-01-01

    This study was performed to evaluate the usefulness of 99m Tc-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy. The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age: 65 years) who had total knee replacement arthroplasty. After injection of 99m Tc-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection: Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positive, one false positive and three true negative in Group B, and six true negatives and two false positive in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively. 99m Tc-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity

  12. Brain spect in the pre-surgical evaluation of epileptic patients preliminary results

    Directory of Open Access Journals (Sweden)

    Carlos A. Buchpiguel

    1992-03-01

    Full Text Available Pre-surgical evaluation of epileptic patients consists of neurological examination, intensive electroencephalographic (EEG monitoring and anatomical studies (CT and MRI. Functional methods such as PET and SPECT imaging are now used more frequently. We have studied pre-operatively 15 adult epileptic patients (8 female, 7 male using a rotational scintillation camera interfaced to a dedicated computer. The tomographic images were obtained 15 minutes after intravenous injection of 99mTc_HMPAO. All had MRI scanning and intensive EEG monitoring which generally included seizure recording. Five patients had progressive lesions (3 meningiomas, 2 astrocytomas. In 10 patients, neuroradiological studies did not show the presence of progressive lesions (2 normal scans and 8 cases with inactive lesions. Two patients with meningioma showed hypoperfusion at the lesion site while the third patient had a marked hyperperfusion which might correlate with the clinical diagnosis of epilepsia partialis continua. In the astrocytoma patients SPECT scans showed hypoperfusion at the lesion site. Data obtained from the 10 patients without progressive CNS lesions showed: (a in 4, SPECT findings correlated well with the anatomical findings; (b in 5 instances, SPECT was able to disclose additional functional deficits; (c in one case, there was no SPECT correlate of a discrete anatomical lesion. In 5 of these cases with no progressive lesions (n=10 SPECT findings were useful as a complementary tool in determining the clinical or surgical management of these patients. Despite the small number and hete-rogenicity of the present sample, SPECT seems to be an useful tool as part of the clinical workup of epileptic patients who are candidates for epilepsy surgery.

  13. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99m Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image

  14. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  15. Assessment of the brain areas perfused by superselective intra-arterial chemotherapy using single photon emission computed tomography with technetium-99m-hexamethyl-propyleneamine oxime. Technical note

    Energy Technology Data Exchange (ETDEWEB)

    Namba, Hiroki; Iwadate, Yasuo; Saegusa, Takashi; Sueyoshi, Kanji [Chiba Cancer Center Hospital (Japan); Kobayashi, Shigeki; Sato, Akira; Watanabe, Yoshiro

    1994-12-01

    The brain areas perfused by superselective intra-arterial (i.a.) chemotherapy were assessed using single photon emission computed tomography (SPECT) with technetium-99m-hexamethyl-propyleneamine oxime ({sup 99m}Tc-HMPAO). A superselective catheter was introduced into the anterior, middle, or posterior cerebral artery of patients with malignant glioma for i.a. chemotherapy. {sup 99m}Tc-HMPAO was subsequently injected via the same catheter used for chemotherapy, and a higher dose of {sup 99m}Tc-HMPAO was injected intravenously to obtain adequate background brain images. Comparison of the SPECT images with magnetic resonance images could confirm complete perfusion of the tumor tissue. In two patients with malignant glioma, regions of interest were selected in the peritumoral brain area and a reference brain area, and the radioactivity was measured. The concentration of {sup 99m}Tc-HMPAO was about 50 times higher in tissue perfused by superselective injection into anterior or middle cerebral artery compared to intravenous injection. {sup 99m}Tc-HMPAO SPECT is readily available in many institutions and the information provided is useful for planning more effective and safe i.a. chemotherapy. (author).

  16. Comparison of continuous with step and shoot acquisition in SPECT scanning

    International Nuclear Information System (INIS)

    McCarthy, L.; Cotterill, T.; Chu, J.M.G.

    1998-01-01

    Full text: Following the recent advent of continuous acquisition for performing SPECT scanning, it was decided to compare the commonly used Step and Shoot mode of acquisition with the new continuous acquisition mode. The aim of the study is to assess any difference in resolution from the resulting images acquired using the two modes of acquisition. Sequential series of studies were performed on a SPECT phantom using both modes of acquisition. Separate sets of data were collected for both high resolution parallel hole and ultra high resolution fan beam collimators. Clinical data was collected on patients undergoing routine gallium, 99m Tc-MDP bone and 99m Tc-HMPAO brain studies. Separate sequential acquisition in both modes were collected for each patient. The sequence of collection was also alternated. Reconstruction was performed utilising the same parameters for each acquisition. The reconstructed data were assessed visually by blinded observers to detect differences in resolution and image quality. No significant difference in the studies collected by either acquisition modes were detected. The time saved by continuous acquisition could be an advantage

  17. {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy in the diagnosis of infection after total knee replacement arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Rib [College of Medicine, Kunkuk Univ., Seoul (Korea, Republic of); Kim, Jae Seung; Ryu, Jin Sook; Moon, Dae Hyuk; Bin, Seong Il; Cho, Woo Shin; Lee, Hee Kyung [College of Medicine, Ulsan Univ., Seoul (Korea, Republic of)

    1999-08-01

    This study was performed to evaluate the usefulness of {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy. The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age: 65 years) who had total knee replacement arthroplasty. After injection of {sup 99m}Tc-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection: Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positive, one false positive and three true negative in Group B, and six true negatives and two false positive in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively. {sup 99m}Tc-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  18. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  19. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  20. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  1. Evaluation of Tl-201 SPECT imaging findings in prostate cancer

    Directory of Open Access Journals (Sweden)

    Sinem Ozyurt

    2015-07-01

    Full Text Available Objectives: To compare with histopathological findings the findings of prostate cancer imaging by SPECT method using Tl-201 as a tumor seeking agent. Methods: The study comprised 59 patients (age range 51-79 years, mean age 65.3 ± 6.8 years who were planned to have transrectal ultrasonography (TRUS-guided biopsies due to suspicion of prostate cancer between April 2011 and September 2011. Early planar, late planar and SPECT images were obtained for all patients. Scintigraphic evaluation was made in relation to uptake presence and patterns in the visual assessment and to Tumor/Background (T/Bg ratios for both planar and SPECT images in the quantitative assessment. Histopathological findings were compatible with benign etiology in 36 (61% patients and malign etiology in 23 (39% patients. Additionally, comparisons were made to evaluate the relationships between uptake patterns,total PSA values and Gleason scores. Results: A statistically significant difference was found between the benign and malignant groups in terms of uptake in planar and SPECT images and T/Bg ratios and PSA values. No statistically significant difference was found between uptake patterns of planar and SPECT images and Gleason scores in the malignant group. Conclusions: SPECT images were superior to planar images in the comparative assessment. Tl-201 SPECT imaging can provide an additional contribution to clinical practice in the diagnosis of prostate cancer and it can be used in selected patients.

  2. Skeletal scintigraphy and SPECT/CT in orthopedic imaging

    International Nuclear Information System (INIS)

    Klaeser, B.; Walter, M.; Krause, T.

    2011-01-01

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  3. Serial studies of cerebral blood flow using 99Tcm-HMPAO

    DEFF Research Database (Denmark)

    Andersen, A R; Friberg, H; Lassen, N A

    1987-01-01

    -HMPAO was measured after i.v. injection. High resolution (HR) and low resolution (LR) studies were performed yielding a resolution of 6 to 10 mm (HR) and 15 to 20 (LR). 99Tcm-HMPAO images showed close resemblance to xenon-133 CBF tomograms. Only about 20% of the (decay corrected) brain counts were lost during...

  4. Preclinical imaging characteristics and quantification of Platinum-195m SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Aalbersberg, E.A.; Wit-van der Veen, B.J. de; Vegt, E.; Vogel, Wouter V. [The Netherlands Cancer Institute (NKI-AVL), Department of Nuclear Medicine, Amsterdam (Netherlands); Zwaagstra, O.; Codee-van der Schilden, K. [Nuclear Research and Consultancy Group (NRG), Petten (Netherlands)

    2017-08-15

    In vivo biodistribution imaging of platinum-based compounds may allow better patient selection for treatment with chemo(radio)therapy. Radiolabeling with Platinum-195m ({sup 195m}Pt) allows SPECT imaging, without altering the chemical structure or biological activity of the compound. We have assessed the feasibility of {sup 195m}Pt SPECT imaging in mice, with the aim to determine the image quality and accuracy of quantification for current preclinical imaging equipment. Enriched (>96%) {sup 194}Pt was irradiated in the High Flux Reactor (HFR) in Petten, The Netherlands (NRG). A 0.05 M HCl {sup 195m}Pt-solution with a specific activity of 33 MBq/mg was obtained. Image quality was assessed for the NanoSPECT/CT (Bioscan Inc., Washington DC, USA) and U-SPECT{sup +}/CT (MILabs BV, Utrecht, the Netherlands) scanners. A radioactivity-filled rod phantom (rod diameter 0.85-1.7 mm) filled with 1 MBq {sup 195m}Pt was scanned with different acquisition durations (10-120 min). Four healthy mice were injected intravenously with 3-4 MBq {sup 195m}Pt. Mouse images were acquired with the NanoSPECT for 120 min at 0, 2, 4, or 24 h after injection. Organs were delineated to quantify {sup 195m}Pt concentrations. Immediately after scanning, the mice were sacrificed, and the platinum concentration was determined in organs using a gamma counter and graphite furnace - atomic absorption spectroscopy (GF-AAS) as reference standards. A 30-min acquisition of the phantom provided visually adequate image quality for both scanners. The smallest visible rods were 0.95 mm in diameter on the NanoSPECT and 0.85 mm in diameter on the U-SPECT{sup +}. The image quality in mice was visually adequate. Uptake was seen in the kidneys with excretion to the bladder, and in the liver, blood, and intestine. No uptake was seen in the brain. The Spearman correlation between SPECT and gamma counter was 0.92, between SPECT and GF-AAS it was 0.84, and between GF-AAS and gamma counter it was0.97 (all p < 0

  5. Reduced hypothalamic blood flow after radiation treatment of nasopharyngeal cancer: SPECT studies in 34 patients

    International Nuclear Information System (INIS)

    Chieng, P.U.; Huang, T.S.; Chang, C.C.; Chong, P.N.; Tien, R.D.; Su, C.T.

    1991-01-01

    To determine the effect of cranial irradiation on hypothalamic blood flow, the authors performed 44 regional cerebral blood flow studies with 99mTc hexamethyl propyleneamine oxime (HMPAO) single-photon emission CT (SPECT) on four normal volunteers and 34 patients with pathologically proved nasopharyngeal cancer. Twenty-three men and 15 women, 30-65 years old, were divided into four study groups: group 1 served as a control and consisted of four normal volunteers and six patients studied prior to cranial irradiation; group 2 patients had cranial irradiation half a year before the SPECT study (n = 12, one from group 1); group 3 patients were irradiated 1 year before the study (n = 13, three from group 1 and two from group 2); and group 4 patients were irradiated at least 5 years before SPECT imaging (n = 9). Six patients were studied twice. Quantification of the 99mTc-HMPAO brain SPECT studies was done separately by three radiologists to obtain the hypothalamus/occipital (H/O) and hypothalamus/parasagittal (H/P) ratios. Endocrinologic studies were performed in all cases and the hypothalamus-thyrotroph-thyroid, hypothalamus-gonadotroph-testis (ovary), hypothalamus-lactotroph, hypothalamus-somatotroph, and hypothalamus-corticotroph-adrenal axes were evaluated separately. They determined that regional hypothalamic blood flow was reduced after cranial irradiation in patients with nasopharyngeal cancer. The H/O ratio of groups 3 and 4 did not differ from that of group 2 (one-half year after cranial irradiation). The H/O ratio was significantly reduced 6 months and 1 year after cranial irradiation; mean ± SD = 0.5801 ± 0.0829 (p less than .025), 0.5725 ± 0.0791 (p less than .01) versus 0.6477 ± 0.0458 before cranial irradiation, respectively

  6. Fusion of SPECT/TC images: Usefulness and benefits in degenerative spinal cord pathology

    International Nuclear Information System (INIS)

    Ocampo, Monica; Ucros, Gonzalo; Bermudez, Sonia; Morillo, Anibal; Rodriguez, Andres

    2005-01-01

    The objectives are to compare CT and SPECT bone scintigraphy evaluated independently with SPECT-CT fusion images in patients with known degenerative spinal pathology. To demonstrate the clinical usefulness of CT and SPECT fusion images. Materials and methods: Thirty-one patients with suspected degenerative spinal disease were evaluated with thin-slice, non-angled helical CT and bone scintigrams with single photon emission computed tomography (SPECT), both with multiplanar reconstructions within a 24-hour period After independent evaluation by a nuclear medicine specialist and a radiologist, multimodality image fusion software was used to merge the CT and SPECT studies and a final consensus interpretation of the combined images was obtained. Results: Thirty-two SPECT bone scintigraphy images, helical CT studies and SPECT-CT fusion images were obtained for 31 patients with degenerative spinal disease. The results of the bone scintigraphy and CT scans were in agreement in 17 pairs of studies (53.12%). In these studies image fusion did not provide additional information on the location or extension of the lesions. In 11 of the study pairs (34.2%), the information obtained was not in agreement between scintigraphy and CT studies: CT images demonstrated several abnormalities, whereas the SPECT images showed only one dominant lesion, or the SPECT images did not provide enough information for anatomical localization. In these cases image fusion helped establish the precise localization of the most clinically significant lesion, which matched the lesion with the greatest uptake. In 4 studies (12.5%) the CT and SPECT images were not in agreement: CT and SPECT images showed different information (normal scintigraphy, abnormal CT), thus leading to inconclusive fusion images. Conclusion: The use of CT-SPECT fusion images in degenerative spinal disease allows for the integration of anatomic detail with physiologic and functional information. CT-SPECT fusion improves the

  7. Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Engbers, Elsemiek M.; Mouden, Mohamed [Isala, Department of Cardiology, Zwolle (Netherlands); Isala, Department of Nuclear Medicine, Zwolle (Netherlands); Timmer, Jorik R.; Ottervanger, Jan Paul [Isala, Department of Cardiology, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala, Department of Nuclear Medicine, Zwolle (Netherlands)

    2017-01-15

    To investigate the impact of left bundle branch block (LBBB) on sequential single photon emission computed tomography (SPECT)/ CT imaging starting with stress-first SPECT. Consecutive symptomatic low- to intermediate-risk patients without a history of coronary artery disease (CAD) referred for SPECT/CT were included from an observational registry. If stress SPECT was abnormal, additional rest SPECT and, if feasible, coronary CT angiography (CCTA) were acquired. Of the 5,018 patients, 218 (4.3 %) demonstrated LBBB. Patients with LBBB were slightly older than patients without LBBB (65±12 vs. 61±11 years, p<0.001). Stress SPECT was more frequently abnormal in patients with LBBB (82 % vs. 46 %, p<0.001). After reviewing stress and rest images, SPECT was normal in 43 % of the patients with LBBB, compared to 77 % of the patients without LBBB (p<0.001). Sixty-four of the 124 patients with LBBB and abnormal stress-rest SPECT underwent CCTA (52 %), which could exclude obstructive CAD in 46 of the patients (72 %). Sequential SPECT/CT imaging starting with stress SPECT is not the optimal imaging protocol in patients with LBBB, as the majority of these patients have potentially false-positive stress SPECT. First-line testing using CCTA may be more appropriate in low- to intermediate-risk patients with LBBB. (orig.)

  8. Reduced contralateral hemispheric flow measured by SPECT in cerebellar lesions

    DEFF Research Database (Denmark)

    Sönmezoğlu, K; Sperling, B; Henriksen, T

    1993-01-01

    Four patients with clinical signs of cerebellar stroke were studied twice by SPECT using 99mTc-HMPAO as a tracer for cerebral blood flow (CBF). When first scanned 6 to 22 days after onset, all had a region of very low CBF in the symptomatic cerebellar hemisphere, and a mild to moderate CBF reduct...

  9. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  10. SPECT/CT imaging in general orthopedic practice.

    Science.gov (United States)

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  11. Role of SPECT imaging in symptomatic posterior element lumbar stress injuries

    Directory of Open Access Journals (Sweden)

    Debnath U

    2005-01-01

    Full Text Available Background : Diagnosis of stress injuries of spine is very difficult with conventional radiography. Methods : In a observational study, 132 subjects were recruited (between 8 and 38 years of age, who had lumbar spondylolysis or posterior element stress injuries. All these patients underwent clinical examination followed by plain X-rays, planar bone scintigraphy and SPECT (single photon emission computerised tomography. SPECT scans can identify the posterior element lumbar stress injuries earlier than other imaging modalities. As the lesions evolve and the completed spondylolysis becomes chronic, the SPECT scans tend to revert to normal even though healing of the defect has not occurred. The aim of the study was to determine the time lag after which SPECT imaging tends to be negative. We divided the patients into two groups, one SPECT positive group and the other SPECT negative group. Pre treatment background variables such as age, gender, back pain in extension or flexion, sporting activities, time of onset of symptoms, Oswestry Disability Index (ODI were used in a univariate logistic regression model to find the strong predictors of positive SPECT imaging results. Determinants of positivity versus negativity of SPECT were identified by discriminant analysis using multivariate logistic regression. Results : Seventy nine patients had positive SPECT scans whereas 53 patients had negative SPECT scans. Bilateral increased uptake was more common than unilateral uptake. Increased uptake at the L5 lumbar spine was more common (70% in SPECT positive group. Low back pain in extension was significantly more common in SPECT positive subjects. Active sporting individuals had higher probability of having a positive SPECT scan. The mean time lag from the onset of low back pain to SPECT imaging was 7 months in SPECT positive group and 25 months in the SPECT negative group. Multivariate analysis predicted that there is a significant difference in positivity of

  12. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  13. 99mTc-ECD brain perfusion SPECT in hyperalgesic fibromyalgia

    International Nuclear Information System (INIS)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Mundler, Olivier; Niboyet, Jean

    2007-01-01

    Neuro-imaging studies with 99m Tc-HMPAO SPECT in fibromyalgia (FM) patients have reported only limited subcortical hypoperfusion. 99m Tc-ECD SPECT is known to provide better evaluation of areas of high cerebral blood flow and regional metabolic rate. We evaluated a homogeneous group of hyperalgesic patients with FM using 99m Tc-ECD SPECT. The aim of this study was to investigate brain processing associated with spontaneous pain in FM patients. Eighteen hyperalgesic FM women (mean age 49 years, range 25-63 years; American College of Rheumatology criteria) and ten healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). Visual Analogue Scale score for pain was 82±4 at the time of the SPECT study. Compared with control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis, with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. In the present study, performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in the sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective-attentional dimension. As current pharmacological and non-pharmacological therapies act differently on the two components of pain, we hypothesise that SPECT could be a valuable and readily available tool to guide individual therapeutic strategy and provide objective follow-up of pain processing recovery under treatment. (orig.)

  14. Clinical applications of SPECT/CT in imaging the extremities

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Strobel, Klaus

    2014-01-01

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  15. Clinical applications of SPECT/CT in imaging the extremities

    Energy Technology Data Exchange (ETDEWEB)

    Huellner, Martin W. [University Hospital Zurich, Department of Medical Radiology, Division of Nuclear Medicine, Zurich (Switzerland); Strobel, Klaus [Lucerne Cantonal Hospital, Department of Nuclear Medicine and Radiology, Lucerne (Switzerland)

    2014-05-15

    Today, SPECT/CT is increasingly used and available in the majority of larger nuclear medicine departments. Several applications of SPECT/CT as a supplement to or replacement for traditional conventional bone scintigraphy have been established in recent years. SPECT/CT of the upper and lower extremities is valuable in many conditions with abnormal bone turnover due to trauma, inflammation, infection, degeneration or tumour. SPECT/CT is often used in patients if conventional radiographs are insufficient, if MR image quality is impaired due to metal implants or in patients with contraindications to MR. In complex joints such as those in the foot and wrist, SPECT/CT provides exact anatomical correlation of pathological uptake. In many cases SPECT increases the sensitivity and CT the specificity of the study, increasing confidence in the final diagnosis compared to planar images alone. The CT protocol should be adapted to the clinical question and may vary from very low-dose (e.g. attenuation correction only), to low-dose for anatomical correlation, to normal-dose protocols enabling precise anatomical resolution. The aim of this review is to give an overview of SPECT/CT imaging of the extremities with a focus on the hand and wrist, knee and foot, and for evaluation of patients after joint arthroplasty. (orig.)

  16. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: takahsr@hs.med.kyushu-u.ac.jp; Sasaki, Masayuki [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao [Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Baba, Shingo [Department of Clinical Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2015-04-15

    Purpose: Yittrium-90 ({sup 90}Y) is traditionally thought of as a pure beta emitter, and is used in targeted radionuclide therapy, with imaging performed using bremsstrahlung single-photon emission computed tomography (SPECT). However, because {sup 90}Y also emits positrons through internal pair production with a very small branching ratio, positron emission tomography (PET) imaging is also available. Because of the insufficient image quality of {sup 90}Y bremsstrahlung SPECT, PET imaging has been suggested as an alternative. In this paper, the authors present the Monte Carlo-based simulation–reconstruction framework for {sup 90}Y to comprehensively analyze the PET and SPECT imaging techniques and to quantitatively consider the disadvantages associated with them. Methods: Our PET and SPECT simulation modules were developed using Monte Carlo simulation of Electrons and Photons (MCEP), developed by Dr. S. Uehara. PET code (MCEP-PET) generates a sinogram, and reconstructs the tomography image using a time-of-flight ordered subset expectation maximization (TOF-OSEM) algorithm with attenuation compensation. To evaluate MCEP-PET, simulated results of {sup 18}F PET imaging were compared with the experimental results. The results confirmed that MCEP-PET can simulate the experimental results very well. The SPECT code (MCEP-SPECT) models the collimator and NaI detector system, and generates the projection images and projection data. To save the computational time, the authors adopt the prerecorded {sup 90}Y bremsstrahlung photon data calculated by MCEP. The projection data are also reconstructed using the OSEM algorithm. The authors simulated PET and SPECT images of a water phantom containing six hot spheres filled with different concentrations of {sup 90}Y without background activity. The amount of activity was 163 MBq, with an acquisition time of 40 min. Results: The simulated {sup 90}Y-PET image accurately simulated the experimental results. PET image is visually

  17. Brain lesion analysis using three-dimensional SPECT imaging

    International Nuclear Information System (INIS)

    Shibata, Iekado; Onagi, Atsuo; Kuroki, Takao

    1995-01-01

    A three-headed gamma camera (PRISM 3000) is capable to scan the protocol of early dynamic SPECT and to analyze two radioisotopes at the same time. We have framed three-dimensional brain SPECT images for several brain diseases by using the Application Visualization System (AVS). We carried out volume measurements in brain tumors and/or AVMs by applying this methodology. Thallium-201 and/or 123I-IMP were used for brain SPECT imaging. The dynamic scan protocol was changed in accordance with the given disease. The protocol for brain tumors was derived from a preliminary comparative study with thallium-201 and 123I-IMP that had suggested a disparity in the detection of brain tumors and the differentiation between tumor tissue and normal brain. The three-dimension SPECT image represented the brain tumor or AVM in a striking fashion, and the changes with respect to tumor or AVM after radiosurgery or embolization were understood readily. (author)

  18. Study of regional cerebral blood flow SPECT imaging for sudden sensorineural deafness

    International Nuclear Information System (INIS)

    Xie Changhui; Kui Xixiao; Xiong Qibin; Wen Hui; Xie Jiabiao

    1998-01-01

    Purpose: To study the clinical value of regional cerebral blood flow (rCBF) SPECT imaging for sudden sensorineural deafness (SSD). Methods: 10 normal persons, 19 conductive deafness and 31 SSD patients were examined by rCBF SPECT imaging, and compared with X CT at the same time. All SSD patients were followed up for 6∼12 months with repeated rCBF SPECT imaging. Results: 1) The radioactivity of diseased and normal horizontal temporal gyrus ratio (T/NT) in SSD patients was the lowest among three groups (P < 0.01). 2) The sensitivity (80.6%) and accurate rate (88.3%) of rCBF SPECT imaging in SSD patients were much higher than those of CT (3.2% and 50%, P < 0.01). 3) There was a significant correlation between degree of deafness and T/NT in SSD patients. 4) Good prognosis of SSD patients with normal rCBF SPECT was found. 5) The rCBF SPECT had close concordance between rCBF SPECT imaging and clinical prognosis (84.6%). Conclusions: rCBF SPECT imaging was superior to X CT in diagnosis of SSD and played an important clinical role

  19. Initial Investigation of preclinical integrated SPECT and MR imaging.

    Science.gov (United States)

    Hamamura, Mark J; Ha, Seunghoon; Roeck, Werner W; Wagenaar, Douglas J; Meier, Dirk; Patt, Bradley E; Nalcioglu, Orhan

    2010-02-01

    Single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high-spatial resolution anatomical information as well as complementary functional information. In this study, we utilized a dual modality SPECT/MRI (MRSPECT) system to investigate the integration of SPECT and MRI for improved image accuracy. The MRSPECT system consisted of a cadmium-zinc-telluride (CZT) nuclear radiation detector interfaced with a specialized radiofrequency (RF) coil that was placed within a whole-body 4 T MRI system. The importance of proper corrections for non-uniform detector sensitivity and Lorentz force effects was demonstrated. MRI data were utilized for attenuation correction (AC) of the nuclear projection data and optimized Wiener filtering of the SPECT reconstruction for improved image accuracy. Finally, simultaneous dual-imaging of a nude mouse was performed to demonstrated the utility of co-registration for accurate localization of a radioactive source.

  20. Design and evaluation of two multi-pinhole collimators for brain SPECT.

    Science.gov (United States)

    Chen, Ling; Tsui, Benjamin M W; Mok, Greta S P

    2017-10-01

    SPECT is a powerful tool for diagnosing or staging brain diseases such as Alzheimer's disease (AD) and Parkinson's disease (PD) but is limited by its inferior resolution and sensitivity. At the same time, pinhole SPECT provides superior resolution and detection efficiency trade-off as compared to the conventional parallel-hole collimator for imaging small field-of-view (FOV), which fits for the case of brain imaging. In this study, we propose to develop and evaluate two multi-pinhole (MPH) collimator designs to improve the imaging of cerebral blood flow and striatum. We set the target resolutions to be 12 and 8 mm, respectively, and the FOV at 200 mm which is large enough to cover the whole brain. The constraints for system optimization include maximum and minimum detector-to-center-of-FOV (CFOV) distances of 344 and 294 mm, respectively, and minimal radius-of-rotation (ROR) of 135 mm to accommodate patients' shoulder. According to the targeted FOV, resolutions, and constraints, we determined the pinhole number, ROR, focal length, aperture acceptance angle, and aperture diameter which maximized the system sensitivity. We then assessed the imaging performance of the proposed MPH and standard low-energy high-resolution (LEHR) collimators using analytical simulations of a digital NCAT brain phantom with 99m Tc-HMPAO/ 99m Tc-TRODAT-1 distributions; Monte Carlo simulations of a hot-rod phantom; and a Defrise phantom using GATE v6.1. Projections were generated over 360° and reconstructed using the 3D MPH/LEHR OS-EM methods with up to 720 updates. The normalized mean square error (NMSE) was calculated over the cerebral and striatal regions extracted from the reconstructed images for 99m Tc-HMPAO and 99m Tc-TRODAT-1 simulations, respectively, and average normalized standard deviation (NSD) based on 20 noise realizations was assessed on selected uniform 3D regions as the noise index. Visual assessment and image profiles were applied to the results of Monte Carlo

  1. Increased rCBF in gray matter heterotopias detected by SPECT using 99mTc hexamethyl-propylenamine oxime

    International Nuclear Information System (INIS)

    Henkes, H.; Klinikum Rudolf Virchow, Berlin; Hosten, N.; Cordes, M.; Neumann, K.; Hansen, M.L.

    1991-01-01

    Imaging findings of morphology and regional cerebral blood flow in two patients suffering from epileptic seizures are presented. CT and MRI revealed heterotopic gray matter as a probable structural correlate, causing the seizure disorder. 99m Tc hexamethyl-propylenamine oxime (HM-PAO) SPECT demonstrated focally increased regional cerebral blood flow in both patients in the areas of their heterotopic lesions. Heterotopic and orthotopic gray matter seem to have similar features in terms of regional perfusion. A focally increased brain perfusion in interictal epileptic patients may indicate an underlying migration anomaly. (orig.)

  2. A Comparative Study of SPECT, q-EEG and CT in Patients with Mild, Acute Head Trauma

    International Nuclear Information System (INIS)

    Lee, Suk Ho; Kim, Jin Seok; Moon, Hee Seung

    1993-01-01

    Functional cerebral impairments have been verified objectively by brain SPECT and q-EEG (quantitative electroencephalography). Microcerebral circulatory defects without anatomical changes cannot be detected by the brain CT or MRI. Brain SPECT using 99m Tc-HMPAO (Hexamethyl propyleneamine oxime) as a key radioisotope may be accepted as the useful method for identifying functional cerebral impairments. We studied 25 patients with mild head trauma to define whether the SPECT was helpful in detecting cerebral impairment. The SPECT was positive in 23 patients out of 25, q-EEG positive in 16 patients and brain CT was positive in 3 cases. SPECT and q-EEG were more sensitive than CT. SPECT would be more useful method than brain CT to investigate cerebral function after head injury

  3. Novel SPECT Technologies and Approaches in Cardiac Imaging

    Directory of Open Access Journals (Sweden)

    Piotr Slomka

    2016-12-01

    Full Text Available Recent novel approaches in myocardial perfusion single photon emission CT (SPECT have been facilitated by new dedicated high-efficiency hardware with solid-state detectors and optimized collimators. New protocols include very low-dose (1 mSv stress-only, two-position imaging to mitigate attenuation artifacts, and simultaneous dual-isotope imaging. Attenuation correction can be performed by specialized low-dose systems or by previously obtained CT coronary calcium scans. Hybrid protocols using CT angiography have been proposed. Image quality improvements have been demonstrated by novel reconstructions and motion correction. Fast SPECT acquisition facilitates dynamic flow and early function measurements. Image processing algorithms have become automated with virtually unsupervised extraction of quantitative imaging variables. This automation facilitates integration with clinical variables derived by machine learning to predict patient outcome or diagnosis. In this review, we describe new imaging protocols made possible by the new hardware developments. We also discuss several novel software approaches for the quantification and interpretation of myocardial perfusion SPECT scans.

  4. Problems in the optimum display of SPECT images

    International Nuclear Information System (INIS)

    Fielding, S.L.

    1988-01-01

    The instrumentation, computer hardware and software, and the image display system are all very important in the production of diagnostically useful SPECT images. Acquisition and processing parameters are discussed which can affect the quality of SPECT images. Regular quality control of the gamma camera and computer is important to keep the artifacts due to instrumentation to a minimum. The choice of reconstruction method will depend on the statistics in the study. The paper has shown that for high count rate studies, a high pass filter can be used to enhance the reconstructions. For lower count rate studies, pre-filtering is useful and the data can be reconstructed into thicker slices to reduce the effect of image noise. Finally, the optimum display for the images must be chosen, so that the information contained in the SPECT data can be easily perceived by the clinician. (orig.) [de

  5. Complexity and accuracy of image registration methods in SPECT-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Yin, L S; Duzenli, C; Moiseenko, V [Physics and Astronomy, University of British Columbia, 6224 Agricultural Road, Vancouver, BC, V6T 1Z1 (Canada); Tang, L; Hamarneh, G [Computing Science, Simon Fraser University, 9400 TASC1, Burnaby, BC, V5A 1S6 (Canada); Gill, B [Medical Physics, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Celler, A; Shcherbinin, S [Department of Radiology, University of British Columbia, 828 West 10th Ave, Vancouver, BC, V5Z 1L8 (Canada); Fua, T F; Thompson, A; Sheehan, F [Radiation Oncology, Vancouver Cancer Centre, BC Cancer Agency, 600 West 10th Ave, Vancouver, BC, V5Z 4E6 (Canada); Liu, M [Radiation Oncology, Fraser Valley Cancer Centre, BC Cancer Agency, 13750 9th Ave, Surrey, BC, V3V 1Z2 (Canada)], E-mail: lyin@bccancer.bc.ca

    2010-01-07

    The use of functional imaging in radiotherapy treatment (RT) planning requires accurate co-registration of functional imaging scans to CT scans. We evaluated six methods of image registration for use in SPECT-guided radiotherapy treatment planning. Methods varied in complexity from 3D affine transform based on control points to diffeomorphic demons and level set non-rigid registration. Ten lung cancer patients underwent perfusion SPECT-scans prior to their radiotherapy. CT images from a hybrid SPECT/CT scanner were registered to a planning CT, and then the same transformation was applied to the SPECT images. According to registration evaluation measures computed based on the intensity difference between the registered CT images or based on target registration error, non-rigid registrations provided a higher degree of accuracy than rigid methods. However, due to the irregularities in some of the obtained deformation fields, warping the SPECT using these fields may result in unacceptable changes to the SPECT intensity distribution that would preclude use in RT planning. Moreover, the differences between intensity histograms in the original and registered SPECT image sets were the largest for diffeomorphic demons and level set methods. In conclusion, the use of intensity-based validation measures alone is not sufficient for SPECT/CT registration for RTTP. It was also found that the proper evaluation of image registration requires the use of several accuracy metrics.

  6. Development of a new statistical evaluation method for brain SPECT images

    International Nuclear Information System (INIS)

    Kawashima, Ryuta; Sato, Kazunori; Ito, Hiroshi; Koyama, Masamichi; Goto, Ryoui; Yoshioka, Seiro; Ono, Shuichi; Sato, Tachio; Fukuda, Hiroshi

    1996-01-01

    The purpose of this study was to develop a new statistical evaluation method for brain SPECT images. First, we made normal brain image databases using 99m Tc-ECD and SPECT in 10 normal subjects as described previously. Each SPECT images were globally normalized and anatomically standardized to the standard brain shape using Human Brain Atlas (HBA) of Roland et al. and each subject's X-CT. Then, mean and SD images were calculated voxel by voxel. For the next step, 99m Tc-ECD SPECT images of a patient were obtained, and global normalization and anatomical standardization were performed as the same way. Then, a statistical map was calculated as following voxel by voxel; (P-Mean)/SDx10+50, where P, mean and SD indicate voxel value of patient, mean and SD images of normal databases, respectively. We found this statistical map was helpful for clinical diagnosis of brain SPECT studies. (author)

  7. Pre-evaluation study in SPECT images using a phantom

    International Nuclear Information System (INIS)

    Rebelo, Marina de Sa; Furuie, Sergio Shiguemi; Abe, Rubens; Moura, Lincoln

    1996-01-01

    An alternative solution for the reconstruction of SPECT images using a Poisson Noise Model is presented. The proposed algorithm was applied on a real phantom and compared to the standard clinical procedures. Results have shown that the proposed method improves the quality of the SPECT images

  8. Correlation with neuropsychological assessment and SPM analysis of brain perfusion SPECT in patients with progressive supranuclear palsy

    International Nuclear Information System (INIS)

    Jeong, Young Jin; Kang, Do Young; Park, Kyung Won; Kim, Jae Woo

    2004-01-01

    Progressive supranuclear palsy (PSP) is a degenerative condition of unknown aetiology that produces an akinetic-rigid form of parkinsonism characterised by early falls, dementia and abnormalities of extraocular movements. The patterns of decreased regional cerebral blood flow and cognitive impairment in PSP compared with normal control have been insufficiently investigated and a limited number of studies have been performed. We evaluated clinical symptoms, functional neuroimaging study using Tc-99m HMPAO SPECT and neuropsychological profiles in patients with PSP. Eleven patients with PSP diagnosed by the clinical criteria of National Institute of Neurological Disorders and Stroke and the Society for PSP (NINDS-SPSP) (mean age: 70.5±5.6 years, educational period: 4.5±4.7 years) and age-matched 10 healthy control subjects (mean age: 68.1±4.5 years, educational period: 6.5±4.1 years) participated in this study were participated. All patients were given a neurologic examination, brain MRI and cerebral perfusion SPECT using Tc-99m HMPAO. We concomittently evaluated several cognitive profiles using the Seoul Neuropsychological Screening Battery. SPM analysis of the SPECT image showed significant perfusion deficits in the left inferior frontal gyrus, left caudate nucleus, left middle frontal gyrus and cingulate gyrus in the patients with PSP compared with age-matched healthy control (uncorrected p<0.01). On neuropsychological assessment, cognitive deficits on verbal and visual memory, word fluency and frontal executive functions were prominent in most patients with PSP compared with healthy control subjects. Our findings suggest that measurement of regional cerebral blood flow by perfusion SPECT and voxel-based SPM analysis with neuropsychological assessment are useful to understanding the correlation between perfusion deficits and abnormal cognitive profiles in patients with PSP

  9. Correlation with neuropsychological assessment and SPM analysis of brain perfusion SPECT in patients with progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Young Jin; Kang, Do Young; Park, Kyung Won; Kim, Jae Woo [School of Medicine, Dong-A University, Busan (Korea, Republic of)

    2004-07-01

    Progressive supranuclear palsy (PSP) is a degenerative condition of unknown aetiology that produces an akinetic-rigid form of parkinsonism characterised by early falls, dementia and abnormalities of extraocular movements. The patterns of decreased regional cerebral blood flow and cognitive impairment in PSP compared with normal control have been insufficiently investigated and a limited number of studies have been performed. We evaluated clinical symptoms, functional neuroimaging study using Tc-99m HMPAO SPECT and neuropsychological profiles in patients with PSP. Eleven patients with PSP diagnosed by the clinical criteria of National Institute of Neurological Disorders and Stroke and the Society for PSP (NINDS-SPSP) (mean age: 70.5{+-}5.6 years, educational period: 4.5{+-}4.7 years) and age-matched 10 healthy control subjects (mean age: 68.1{+-}4.5 years, educational period: 6.5{+-}4.1 years) participated in this study were participated. All patients were given a neurologic examination, brain MRI and cerebral perfusion SPECT using Tc-99m HMPAO. We concomittently evaluated several cognitive profiles using the Seoul Neuropsychological Screening Battery. SPM analysis of the SPECT image showed significant perfusion deficits in the left inferior frontal gyrus, left caudate nucleus, left middle frontal gyrus and cingulate gyrus in the patients with PSP compared with age-matched healthy control (uncorrected p<0.01). On neuropsychological assessment, cognitive deficits on verbal and visual memory, word fluency and frontal executive functions were prominent in most patients with PSP compared with healthy control subjects. Our findings suggest that measurement of regional cerebral blood flow by perfusion SPECT and voxel-based SPM analysis with neuropsychological assessment are useful to understanding the correlation between perfusion deficits and abnormal cognitive profiles in patients with PSP.

  10. SPECT versus planar bone radionuclide imaging in the detection of spondylolysis

    International Nuclear Information System (INIS)

    Whitten, C.G.; El-Khoury, G.Y.; Chang, P.J.; Seabold, J.E.; Found, E.M.; Renfrew, D.L.

    1991-01-01

    This paper evaluates the relative performance and ease of interpretation of SPECT versus planar radionuclide bone imaging in the detection of spondylolysis. The authors studied all patients presenting with back pain suggestive of spondylolysis from November 1989 to January 1991 who underwent bone scanning; patients underwent both planar and SPECT imaging. The planar and SPECT images were randomly mixed and independently interpreted by four observers for presence or absence of spondylolysis and ease of interpretation for each scan. Receiver operating characteristic (ROC) and analysis of variance (ANOVA) were used. Of 72 patients, 19 had confirmed spondylolysis, and 53 did not. While ROC analysis showed that SPECT performed slightly better than planar imaging for all four observers, the difference was not statistically significant. ANOVA results suggest that planar imaging was significantly easier to use than SPECT and that ease of use was strongly correlated with the observer's confidence in the diagnosis

  11. The development of 99mTc-d, 1-HM-PAO

    International Nuclear Information System (INIS)

    Bai Lanqin; Huang Jinjie; Fan Li; Bai Suzhen; Li Guoli; Jing Hui; Xiao Lun

    1991-12-01

    The 99m Tc-d,1-HM-PAO is an ideal radiopharmaceutical for regional cerebral blood perfusion imaging. The improvement of synthesis and separation of diastereoisomers leads to obtain high purity (>99%) of d, 1-HM-PAO and meso-HM-PAO. During separation H NMR spectroscopy was used to monitor the relative composition of these two diastereoisomers that can ensure the purity of pligand of d,1-HM-PAO. The intravenous injection of 99m Tc-d,1-HM-PAO was formed by adding fresh 99m Tc washing liquor into a sterile. Pyrogen-free and freeze-dried vial. The radiochemical purity (RCP) of 99m Tc-d,1-HM-PAO was greater than 80%. From the experiments of 99m Tc-d,1-HM-PAO in mice, after two minutes of intravenously (I>V>) administration about 2.24% of injected dose (I.D.)appeared in the brain, and after 24 hours about 72% of radioactivity of injected dose still left in the brain. But for the 99m Tc-meso-HM-PAO after two minutes of i.v. administration, about 1.93% of I.D. appeared in the brain, and 24 hours later, 25% of radioactivity of I.D. was in the brain. This result shows that in the brain the radioactivity of 99m Tc-meso-HM-PAO declines faster than that of 99m Td-d,1-HM-PAO

  12. SPECT imaging of cardiac reporter gene expression in living rabbits

    International Nuclear Information System (INIS)

    Liu Ying; Lan Xiaoli; Zhang Liang; Wu Tao; Jiang Rifeng; Zhang Yongxue

    2009-01-01

    This work is to demonstrate feasibility of imaging the expression of herpes simplex virus 1-thymidine kinase (HSVI-tk) reporter gene in rabbits myocardium by using the reporter probe 131 I-2'-fluoro-2'-deoxy-l-β-D-arabinofuranosyl-5-iodouracil ( 131 I-FIAU) and SPECT. Rabbits of the study group received intramyocardial injection of Ad5-tk and control group received aseptic saline injection. Two sets of experiments were performed on the study group. Rabbits of the 1st set were injected with 131 I-FIAU 600 μCi at Day 2 after intramyocardial transfection of Ad5-tk in 1xl0 9 , 5x10 8 , 1x10 8 , 5x10 7 and 1x10 7 pfu, and heart SPECT imaging was done at different hours. Rabbits of the 2nd were transferred various titers of Ad5-tk (1x10 9 , 5x10 8 , 1x10 8 , 5x10 7 , 1x10 7 pfu) to determine the threshold and optimal viral titer needed for detection of gene expression. Two days later, 131 I-FIAU was injected and heart SPECT imaging was performed at 6, 24 and 48 h, before killing them for gamma counting of the hearts. Reverse transcription-polymerase chain reaction (RT-PCR) was used to verify the transferred HSVI-tk gene expression. Semi-quantitative analysis derived of region of interest (ROI) of SPECT images and RT-PCR images was performed and the relationship of SPECT images with ex vivo gamma counting and mRNA level were evaluated. SPECT images conformed 131 I-FIAU accumulation in rabbits injected with Ad5-tk in the anterolateral wall. The optimal images quality was obtained at 24-48 h for different viral titers. The highest radioactivity in the focal myocardium was seen at 6 h, and then declined with time. The threshold was 5x10 7 pfu of virus titer. The result could be set better in 1-5x10 8 pfu by SPECT analysis and gamma counting. ROI-derived semi-quantitative study on SPECT images correlated well with ex vivo gamma counting and mRNA levels from RT-PCR analysis. The HSVI-tk/ 131 I-FIAU reporter gene/reporter probe system is feasible for cardiac SPECT reporter

  13. Follow-up findings in regional cerebral blood flow (r-CBF)-SPECT in a case of idiopathic childhood hemidystonia. Functional neuroimaging and pathophysiological implications

    Energy Technology Data Exchange (ETDEWEB)

    Fiedler, A.; Aderbauer, J.; Segerer, H. [St. Hedwig Hospital, Regensburg (Germany). Dept. of Pediatrics; Marienhagen, J.; Bock, E.; Eilles, C. [Univ. Hospital, Regensburg (Germany). Dept. of Nuclear Medicine

    1999-05-01

    A 9 1/2-year-old girl suffered from intermitting tremor and jitteriness of her left hand and oral muscles every 4 to 6 weeks with long lasting episodes. Clinically myoclonias and dystonic positioning of the left arm, hand and facial muscles were seen. No evidence of trauma, infection or inborn errors of metabolism was found. Successful therapy with carbamazepine was initiated while L-DOPA failed. An ictal 99m-Tc-HMPAO-SPECT showed severe asymmetry with focal hyperperfusion of the contralateral right thalamus and basal ganglia as well as of the bifrontal cortex, whereas no anatomical lesions were found by MRI. In contrast, an interictally performed 99m-Tc-HMPAO SPECT showed hypoperfusion or the right thalamus and normalisation of the frontal perfusion under medical treatment. These 99m-Tc-HMPAO-SPECT findings may provide new insights into the localisation and pathophysiological pathways of idiopathic childhood dystonia. (orig.) [Deutsch] Ein 9 1/2jaehriges Maedchen litt an rezidivierenden, langdauernden Schueben von Tremor und Zittern der linken Hand und der perioralen Muskulatur links. Klinisch fanden sich eine dystone Haltung des linken Armes und unerschoepfliche Myoklonien des Armes, der Hand und der Gesichtsmuskulatur links. Trauma, Infektion oder ein Stoffwechseldefekt als Ursache lagen nicht vor. Ein Therapieversuch mit L-DOPA war erfolglos. Unter Gabe von Carbamazepin wurde Beschwerdefreiheit bleibend erreicht. Ein iktuales 99m-Tc-HMPAO-SPECT zeigte eine fokale Hyperperfusion des rechtsseitigen Thalamus und der Basalganglien, sowie des bifrontalen Kortex. Ein interiktuales 99m-Tc-HMPAOSPECT ergab dann eine deutliche Hypoperfusion des rechtseitigen Thalamus bei normalisierter Perfusion des bifrontalen Kortex. Eine kranielle Magnetresonanztomographie (MRI) ergab einen unauffaelligen Befund. Der Vergleich der iktualen und interiktualen Perfusionsverhaeltnisse weist auf neue pathophysiologische Zusammenhaenge bei idiopathischer kindlicher Dystonie hin. (orig.)

  14. Radiotracers for SPECT imaging. Current scenario and future prospects

    International Nuclear Information System (INIS)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S.

    2012-01-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [ 123 I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [ 123 I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also makes them more

  15. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  16. Atlas of Skeletal SPECT/CT Clinical Images

    International Nuclear Information System (INIS)

    2016-01-01

    The atlas focuses specifically on single photon emission computed tomography/computed tomography (SPECT/CT) in musculoskeletal imaging, and thus illustrates the inherent advantages of the combination of the metabolic and anatomical component in a single procedure. In addition, the atlas provides information on the usefulness of several sets of specific indications. The publication, which serves more as a training tool rather than a textbook, will help to further integrate the SPECT and CT experience in clinical practice by presenting a series of typical cases with many different patterns of SPECT/CT seen in bone scintigraphy

  17. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

    Science.gov (United States)

    Matsuo, Shinro; Nakajima, Kenichi; Onoguchi, Masahisa; Wakabayash, Hiroshi; Okuda, Koichi; Kinuya, Seigo

    2015-06-01

    A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging. Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software. IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009). The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR

  18. NeuroSPECT assessment of ischemic penumbra in acute brain infarct: control of intra-arterial thrombolysis

    International Nuclear Information System (INIS)

    Mena, F.J.; Mena, I.; Contreras, I.; Soto, F.; Ducci, H.; Fruns, M.

    2002-01-01

    Introduction: Brain infarct is the most common cause of incapacity in adults, the second cause of dementia and the 2nd or 3rd cause of death. Acute brain infarct is a medical emergency potentially reversible if treated with thrombolysis in the first hours of evolution. Thrombolysis is now an approved and efficacious method of treatment for acute ischemic stroke. During the first 3 hours of evolution, intravenous administration of plasminogen activator (tPA) can be performed. The window of time of treatment is expanded to 6 hours with the intra-arterial super selective route for thrombolysis. Aim: The aim of this study was to define levels of reversible ischemia (penumbra) demonstrated by statistically evaluated HMPAO Tc99m NeuroSPECT performed before and after intra-arterial thrombolysis in the treatment of acute infarct. Materials and Methods: 21 patients were treated during the first 6 hours of evolution of an acute ischemic stroke with the following protocol. 1) Admission, and complete neurological evaluation. 2) Brain CT scan to rule hemorrhage or established infarct. 3) I.V injection of 1100MBq Tc99m HMPAO (Ceretec tm) 4) Conventional cerebral angiography and intra-arterial thrombolysis and/or angioplasty/stenting if necessary. 5) NeuroSPECT assessment of ischemic penumbra. 6) Control at 24 hrs with NeuroSPECT. NeuroSPECT image acquisition is performed immediately following arterial thrombolysis with a dual Head Camera, SHR collimators and conventional protocol. Image processing was performed using the Segami Software, as previously reported in Alasbimn Journal2 (7): April 2000. http://www.alasbimnjournal.cl. The analysis consists of 1) Tallairach brain volume normalization. 2) Voxel by voxel comparison of the individual brain cortex uptake normalized to the maximum in the cortex with a normal database of 24 age-matched controls. Results: The results are expressed in standard deviations (S.D.) below the normal mean. Normal mean is 72% + 6. Only voxels between

  19. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    International Nuclear Information System (INIS)

    Bowsher, James; Giles, William; Yin, Fang-Fang; Yan, Susu; Roper, Justin

    2014-01-01

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  20. Onboard functional and molecular imaging: A design investigation for robotic multipinhole SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Bowsher, James, E-mail: james.bowsher@duke.edu; Giles, William; Yin, Fang-Fang [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710 (United States); Yan, Susu [Medical Physics Graduate Program, Duke University, Durham, North Carolina 27710 (United States); Roper, Justin [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2014-01-15

    Purpose: Onboard imaging—currently performed primarily by x-ray transmission modalities—is essential in modern radiation therapy. As radiation therapy moves toward personalized medicine, molecular imaging, which views individual gene expression, may also be important onboard. Nuclear medicine methods, such as single photon emission computed tomography (SPECT), are premier modalities for molecular imaging. The purpose of this study is to investigate a robotic multipinhole approach to onboard SPECT. Methods: Computer-aided design (CAD) studies were performed to assess the feasibility of maneuvering a robotic SPECT system about a patient in position for radiation therapy. In order to obtain fast, high-quality SPECT images, a 49-pinhole SPECT camera was designed which provides high sensitivity to photons emitted from an imaging region of interest. This multipinhole system was investigated by computer-simulation studies. Seventeen hot spots 10 and 7 mm in diameter were placed in the breast region of a supine female phantom. Hot spot activity concentration was six times that of background. For the 49-pinhole camera and a reference, more conventional, broad field-of-view (FOV) SPECT system, projection data were computer simulated for 4-min scans and SPECT images were reconstructed. Hot-spot localization was evaluated using a nonprewhitening forced-choice numerical observer. Results: The CAD simulation studies found that robots could maneuver SPECT cameras about patients in position for radiation therapy. In the imaging studies, most hot spots were apparent in the 49-pinhole images. Average localization errors for 10-mm- and 7-mm-diameter hot spots were 0.4 and 1.7 mm, respectively, for the 49-pinhole system, and 3.1 and 5.7 mm, respectively, for the reference broad-FOV system. Conclusions: A robot could maneuver a multipinhole SPECT system about a patient in position for radiation therapy. The system could provide onboard functional and molecular imaging with 4-min

  1. High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging

    International Nuclear Information System (INIS)

    Umeda, Izumi O.; Tani, Kotaro; Tsuda, Keisuke

    2012-01-01

    Tumor interiors are never homogeneous and in vivo visualization of intratumoral heterogeneity would be an innovation that contributes to improved cancer therapy. But, conventional nuclear medicine tests have failed to visualize heterogeneity in vivo because of limited spatial resolution. Recently developed single photon emission computed tomographic (SPECT) scanners dedicated for small animal imaging are of interest due to their excellent spatial resolution of 111 In and simulations of actual small animal imaging. The optimal conditions obtained were validated by in vivo imaging of sarcoma 180-bearing mice. Larger number of counts must be obtained within limited acquisition time to visualize tumor heterogeneity in vivo in animal imaging, compared to cases that simply detect tumors. At an acquisition time of 30 min, better image quality was obtained with pinhole apertures diameter of 1.4 mm than of 1.0 mm. The obtained best spatial resolution was 1.3 mm, it was acceptable for our purpose, though a little worse than the best possible performance of the scanner (1.0 mm). Additionally, the reconstruction parameters, such as noise suppression, voxel size, and iteration/subset number, needed to be optimized under the limited conditions and were different from those found under the ideal condition. The minimal radioactivity concentration for visualization of heterogeneous tumor interiors was estimated to be as high as 0.2-0.5 MBq/mL. Liposomes containing 111 In met this requirement and were administered to tumor-bearing mice. SPECT imaging successfully showed heterogeneous 111 In distribution within the tumors in vivo with good spatial resolution. A threshold of 0.2 MBq/g for clear visualization of tumor heterogeneity was validated. Autoradiograms obtained ex vivo of excised tumors confirmed that the in vivo SPECT images accurately depicted the heterogeneous intratumoral accumulation of liposomes. Intratumoral heterogeneity was successfully visualized under the optimized

  2. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  3. Brain SPECT in psychiatry: Delusion or reality?

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Epstein, P.; Kohn, R.; Antonino, F.; Devore-Best, S.; Craita, I.; Liu, P.

    2002-01-01

    Aim: The need for functional information is becoming increasingly evident for proper therapeutic approaches to the treatment and follow up of psychiatric diseases. While data on this subject already exists, there is a general lack of consensus about the use of brain SPECT in this domain and also a considerable negative prejudice due to a number of factors including poor quality imaging and unrealistic expectations. Based on a large group of brain SPECT-s performed over the past 3 years we attempted to sort and refine the indications for SPECT in psychiatry. Materials and Methods: High resolution brain SPECT was performed with triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A comprehensive semiquantitative color, 3D surface as well as multi-thresholded volume display was routinely used and supplemented by automatic realignment in case of longitudinal follow-up. Results: 470 brain SPECT-s done on 432 patients were all referred by psychiatrists or neuro-psychiatrists for a wide spectrum of psychiatric diseases and ranged in age from 7 to 88 years. The most common primary reasons for referral were : attention deficit hyperactive disorder (ADHD); anxiety; obsessive-compulsive disease, depression (refractory, chronic, bipolar ), impulse control problems; oppositional defiance, post traumatic brain injury; seizures, learning difficulties, pervasive development disorders, memory loss and differential of dementia. Among common denominators were long duration of the disease, unresponsiveness to treatment, worsening of clinical status, and presence of multiple conditions at the same time. The multiparametric display used enabled a comprehensive evaluation of the brain volume which included the hemispheric surfaces; the basal ganglia (striatum) and the thalamus, several components of the limbic and paralimbic systems: anterior and posterior cingulate and their respective subdivisions, insula-s and their subdivisions, apical and mesial

  4. Anything wrong with brain SPECT? Not really

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Craita, I.; Liu, P.

    2002-01-01

    Aim: Despite increased evidence about the usefulness of Brain SPECT in Neuro-Psychiatry, it continues to represent only a low percentage of Nuclear Medicine procedures. The prevalent perception is that it is an inadequate diagnostic tool, and/or is not changing patient management. There are objective reasons for this, as the lack of awareness by Psychiatrists about the value of SPECT, but most important is the frequently poor quality of images provided. This can be due to inadequate gamma cameras but is mostly due to poor quality software. Materials and Methods: High resolution brain SPECT via triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A combination of commercial software and local optimization was used for the final displays as well as for realignment of sequential brain SPECT studies. Results: We found out that 6 basic software improvements are needed to generate a final display where features can be clearly distinguished and which can be also easily assimilated by the referring physician. 1) Color scales: simple and efficient tools needed to generate user friendly and semiquantitative color shades as needed. Unfortunately various color scales may be needed depending on printer and paper used. 2): 3 D displays allowing, multiple standardized thresholdings, any number of groupings, differential coloring (with functional meaning) and adequate labeling. Should be completely or at least mostly automatic. 3) Automatic realignment of sequential studies: such programs exist in various forms (free WWW versions, proprietary Beta versions, etc.) but are still not supplied by the gamma camera vendors for general use. Should provide SPECT -SPECT and SPECT MRI options. 4) Localization of structures and slices a) Triangulation of structures and b) Identification of section location. 5) Graphics improvement for generating any number of optimized summary displays to accompany reports. 6) Availability of voxel based quantification software

  5. Single-photon emission computed tomography (SPECT) in oediatric migraine

    International Nuclear Information System (INIS)

    Battistella, P.A.; Pitassi, I.; Ruffilli, R.; Boniver, C.; Suppiej, A.; Casara, G.

    1989-01-01

    Cerebral blood flow in pediatric patients suffering from different types of migraine is analyzed by SPECT with 99m Tc HM-PAO, during the pain free intervals. The results indicate that such studies may give further information toward the understanding of common and classic forms of migraine and the difference in the CBF patterns of these forms support the hypothesis of a possible different pathogenesis. (H.W.). 13 refs.; 1 tab

  6. Evaluation of linear registration algorithms for brain SPECT and the errors due to hypoperfusion lesions

    International Nuclear Information System (INIS)

    Radau, Perry E.; Slomka, Piotr J.; Julin, Per; Svensson, Leif; Wahlund, Lars-Olof

    2001-01-01

    The semiquantitative analysis of perfusion single-photon emission computed tomography (SPECT) images requires a reproducible, objective method. Automated spatial standardization (registration) of images is a prerequisite to this goal. A source of registration error is the presence of hypoperfusion defects, which was evaluated in this study with simulated lesions. The brain perfusion images measured by 99m Tc-HMPAO SPECT from 21 patients with probable Alzheimer's disease and 35 control subjects were retrospectively analyzed. An automatic segmentation method was developed to remove external activity. Three registration methods, robust least squares, normalized mutual information (NMI), and count difference were implemented and the effects of simulated defects were compared. The tested registration methods required segmentation of the cerebrum from external activity, and the automatic and manual methods differed by a three-dimensional displacement of 1.4±1.1 mm. NMI registration proved to be least adversely effected by simulated defects with 3 mm average displacement caused by severe defects. The error in quantifying the patient-template parietal ratio due to misregistration was 2.0% for large defects (70% hypoperfusion) and 0.5% for smaller defects (85% hypoperfusion)

  7. Crossed cerebellar hyperperfusion on ictal Tc-99m HMPAO brain SPECT: clinical significance for differentiation of mesial or lateral temporal lobe epilepsy and related factors for development

    International Nuclear Information System (INIS)

    Park, Soon Ah; Sohn, Myung Hee; Lim, Seok Tae; Lee, Dong Soo; Lee, Sang Gun; Kim, Seok Ki; Jang, Myoung Jin; Chung, June Key; Lee, Myung Chul

    2000-01-01

    The aim of this study was to determine whether crossed cerebellar hyperperfusion (CCH) was helpful in discriminating mesial from lateral temporal lobe epilepsy (TLE) and what other factors were related in the development of CCH on ictal brain SPECT. We conducted retrospective analysis in 59 patients with TLE (M:41, F:18; 27.4±7.8 years old; mesial TLE: 51, lateral TLE: 8), which was confirmed by invasive EEG and surgical outcome (Engel class 1, 2). All the patients underwent ictal Tc-99m HMPAO brain SPECT and their injection time from ictal EEG onset on video EEG monitoring ranged from 11 sec to 75 sec (32.6±19.5 sec) in 39 patients. Multiple factors including age, TLE subtype (mesial TLE or lateral TLE), propatation pattern (hyperperfusion localized to temporal lobes, spread to adjacent lobes or contralateral hemisphere) and injection time were evaluated for their relationship with CCH using multiple logistic regression analysis CCH was observed in 18 among 59 patients. CCH developed in 29% (15/51) of mesial TLE patients and 38% (3/8) of lateral TLE patients. CCH was associated with propagation pattern; no CCH (0/13) in patients with hyperperfusion localized to temporal lobe, 30% (7/23) in patients with propagation to adjacent lobes, 48% (11/23) to contralateral hemisphere. Multiple logistic regression analysis revealed that propagation pattern (p=3D0.01) and age (p=3D0.02) were related to the development of CCH. Crossed cerebellar hyperperfusion in ictal brain SPECT did not help differentiate mesial from lateral remporal lobe epilepsy. Crossed cerebellar hyperperfusion was associated with propagation pattern of temporal lobe epilepsy and age.=20

  8. Crossed cerebellar hyperperfusion on ictal Tc-99m HMPAO brain SPECT: clinical significance for differentiation of mesial or lateral temporal lobe epilepsy and related factors for development

    Energy Technology Data Exchange (ETDEWEB)

    Park, Soon Ah; Sohn, Myung Hee; Lim, Seok Tae [Chonbuk National Univ. School of Medicine, Chonju (Korea, Republic of); Lee, Dong Soo; Lee, Sang Gun; Kim, Seok Ki; Jang, Myoung Jin; Chung, June Key; Lee, Myung Chul [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2000-08-01

    The aim of this study was to determine whether crossed cerebellar hyperperfusion (CCH) was helpful in discriminating mesial from lateral temporal lobe epilepsy (TLE) and what other factors were related in the development of CCH on ictal brain SPECT. We conducted retrospective analysis in 59 patients with TLE (M:41, F:18; 27.4{+-}7.8 years old; mesial TLE: 51, lateral TLE: 8), which was confirmed by invasive EEG and surgical outcome (Engel class 1, 2). All the patients underwent ictal Tc-99m HMPAO brain SPECT and their injection time from ictal EEG onset on video EEG monitoring ranged from 11 sec to 75 sec (32.6{+-}19.5 sec) in 39 patients. Multiple factors including age, TLE subtype (mesial TLE or lateral TLE), propatation pattern (hyperperfusion localized to temporal lobes, spread to adjacent lobes or contralateral hemisphere) and injection time were evaluated for their relationship with CCH using multiple logistic regression analysis CCH was observed in 18 among 59 patients. CCH developed in 29% (15/51) of mesial TLE patients and 38% (3/8) of lateral TLE patients. CCH was associated with propagation pattern; no CCH (0/13) in patients with hyperperfusion localized to temporal lobe, 30% (7/23) in patients with propagation to adjacent lobes, 48% (11/23) to contralateral hemisphere. Multiple logistic regression analysis revealed that propagation pattern (p=3D0.01) and age (p=3D0.02) were related to the development of CCH. Crossed cerebellar hyperperfusion in ictal brain SPECT did not help differentiate mesial from lateral remporal lobe epilepsy. Crossed cerebellar hyperperfusion was associated with propagation pattern of temporal lobe epilepsy and age.

  9. Clinical applications of SPECT/CT: New hybrid nuclear medicine imaging system

    International Nuclear Information System (INIS)

    2008-08-01

    Interest in multimodality imaging shows no sign of subsiding. New tracers are spreading out the spectrum of clinical applications and innovative technological solutions are preparing the way for yet more modality marriages: hybrid imaging. Single photon emission computed tomography (SPECT) has enabled the evaluation of disease processes based on functional and metabolic information of organs and cells. Integration of X ray computed tomography (CT) into SPECT has recently emerged as a brilliant diagnostic tool in medical imaging, where anatomical details may delineate functional and metabolic information. SPECT/CT has proven to be valuable in oncology. For example, in the case of a patient with metastatic thyroid cancer, neither SPECT nor CT alone could identify the site of malignancy. SPECT/CT, a hybrid image, precisely identified where the surgeon should operate. However SPECT/CT is not just advantageous in oncology. It may also be used as a one-stop-shop for various diseases. Clinical applications with SPECT/CT have started and expanded in developed countries. It has been reported that moving from SPECT alone to SPECT/CT could change diagnoses in 30% of cases. Large numbers of people could therefore benefit from this shift all over the world. This report presents an overview of clinical applications of SPECT/CT and a relevant source of information for nuclear medicine physicians, radiologists and clinical practitioners. This information may also be useful for decision making when allocating resources dedicated to the health care system, a critical issue that is especially important for the development of nuclear medicine in developing countries. In this regard, the IAEA may be heavily involved in the promotion of programmes aimed at the IAEA's coordinated research projects and Technical Cooperation projects

  10. Diagnosis and staging of breast cancer by SPECT images fused with CT images

    International Nuclear Information System (INIS)

    Li Yanjing; Zhu Qiaomei

    2007-01-01

    Objective: To evaluate the TNM staging value of 99mTc-MIBI scintimammotraphy with SPECT-CT images fusing for the diagnosis of breast cancer. Methods: 10 patients with breast cancer underwent scintimammography with 99mTc-MIBI, and SPECT images were fused with CT images. Images were compared with final diagnosis confirmed by histopathology. Results: Of the 19 breast cancer patients, one case of invasive ductal carcinoma showed false-negative. Among 18 cases of positive lesions, axillary metastases were involved in 10, supraclavicular nodes were also defined in 3, para-sternum nodes were involved in 2, 2 were missed and 1 cases without metastatic node. The axillary lymph nodes were divided into three levels with respect to their position relative to the pectoralis minor muscle by fused images. Conclusion: 99mTc-MIBI scintimammotraphy combined with SPECT-CT images fusing is of some clinical value in TNM staging of breast cancer. (authors)

  11. Imaging fusion (SPECT/CT) in degenerative disease of spine

    International Nuclear Information System (INIS)

    Bernal, P.; Ucros, G.; Bermudez, S.; Ocampo, M.

    2007-01-01

    Full text: Objective: To determine the utility of Fusion Imaging SPECT/CT in degenerative pathology of the spine and to establish the impact of the use of fusion imaging in spinal pain due to degenerative changes of the spine. Materials and methods: 44 Patients (M=21, F=23) average age of 63 years and with degenerative pathology of spine were sent to Diagnosis Imaging department in FSFB. Bone scintigraphy (SPECT), CT of spine (cervical: 30%, Lumbar 70%) and fusion imaging were performed in all of them. Bone scintigraphy was carried out in a gamma camera Siemens Diacam double head attached to ESOFT computer. The images were acquired in matrix 128 x 128, 20 seg/imag, 64 images. CT of spine was performed same day or two days after in Helycoidal Siemens somatom emotion CT. The fusion was done in a Dicom workstation in sagital, axial and coronal reconstruction. The findings were evaluated by 2 Nuclear Medicine physicians and 2 radiologists of the staff of FSFB in an independent way. Results: Bone scan (SPECT) and CT of 44 patients were evaluated. CT showed facet joint osteoarthrities in 27 (61.3%) patients, uncovertebral joint arthrosis in 7 (15.9%), bulging disc in 9(20.4%), spinal nucleus lesion in 7(15.9%), osteophytes in 9 (20.4%), spinal foraminal stenosis in 7 (15.9%), spondylolysis/spondylolisthesis in 4 (9%). Bone scan showed facet joint osteoarthrities in 29 (65.9%), uncovertebral joint arthrosis in 4 (9%), osteophytes in 9 (20.4%) and normal 3 (6.8%). The imaging fusion showed coincidence findings (main lesion in CT with high uptake in scintigraphy) in 34 patients (77.2%) and no coincidence in 10 (22.8%). In 15 (34.09%) patients the fusion provided additional information. The analysis of the findings of CT and SPECT showed similar results in most of the cases and the fusion didn't provide additional information but it allowed to confirm the findings but when the findings didn't match where the CT showed several findings and SPECT only one area with high uptake

  12. {sup 99m}Tc-ECD brain perfusion SPECT in hyperalgesic fibromyalgia

    Energy Technology Data Exchange (ETDEWEB)

    Guedj, Eric; Taieb, David; Cammilleri, Serge; Lussato, David; Laforte, Catherine de; Mundler, Olivier [Assistance Publique des Hopitaux de Marseille, Centre Hospitalo-Universitaire de la Timone, Service Central de Biophysique et de Medecine Nucleaire, Marseille Cedex 05 (France); Niboyet, Jean [Clinique La Phoceanne, Unite d' Etude et de Traitement de la Douleur, Marseille (France)

    2007-01-15

    Neuro-imaging studies with {sup 99m}Tc-HMPAO SPECT in fibromyalgia (FM) patients have reported only limited subcortical hypoperfusion. {sup 99m}Tc-ECD SPECT is known to provide better evaluation of areas of high cerebral blood flow and regional metabolic rate. We evaluated a homogeneous group of hyperalgesic patients with FM using {sup 99m}Tc-ECD SPECT. The aim of this study was to investigate brain processing associated with spontaneous pain in FM patients. Eighteen hyperalgesic FM women (mean age 49 years, range 25-63 years; American College of Rheumatology criteria) and ten healthy women matched for age were enrolled in the study. A voxel-by-voxel group analysis was performed using SPM2 (p<0.05, corrected for multiple comparisons). Visual Analogue Scale score for pain was 82{+-}4 at the time of the SPECT study. Compared with control subjects, we observed individual brain SPECT abnormalities in FM patients, confirmed by SPM2 analysis, with hyperperfusion of the somatosensory cortex and hypoperfusion of the frontal, cingulate, medial temporal and cerebellar cortices. In the present study, performed without noxious stimuli in hyperalgesic FM patients, we found significant hyperperfusion in regions of the brain known to be involved in the sensory dimension of pain processing and significant hypoperfusion in areas assumed to be associated with the affective-attentional dimension. As current pharmacological and non-pharmacological therapies act differently on the two components of pain, we hypothesise that SPECT could be a valuable and readily available tool to guide individual therapeutic strategy and provide objective follow-up of pain processing recovery under treatment. (orig.)

  13. Clinical value of SPECT/CT imaging in the diagnosis of bone metastasis

    International Nuclear Information System (INIS)

    Wang Xinhua; Zhao Yanping; Lu Haijian; Dong Zhanfei

    2010-01-01

    Objective: To evaluate the clinical value of 99 Tc m -methylene diphosphonic acid (MDP) SPECT/CT imaging for the diagnosis of bone metastasis. Methods: Patients suspected for bone metastasis and with bone pain of unknown origin were included in this study (n=237). All cases underwent SPECT and CT imaging at 180 min after 99 Tc m -MDP injection. Diagnosis was confirmed by pathology (n=21), more than 2 kinds of radiologieal imaging (MRI, CT, X-ray) (n=106), and clinical follow up in 2 years (n=110). χ 2 -test was used to compare the results of planar and SPECT/CT imaging using SAS 6.12 software. Results: In 237 patients, planar imaging of 142 cases matched the final diagnosis in which 72 had benign lesions and 70 had bone metastases. The definite coincidence rate was 95.30% (142/149). SPECT/CT imaging of 224 cases matched the final diagnosis in which 104 had benign lesions and 120 cases diagnosed as bone metastases. The coincidence and definite coincidence rates were 94.51% (224/237), and 99.48% (192/193). Difference in the definite coincidence rate between planar and SPECT/CT imaging was statistically significant (χ 2 = 5.37, P=0.024). Conclusion: SPECT/CT imaging is valuable for accurate localization of osseous pathology and for improvement of diagnosing bone metastasis. (authors)

  14. Physical and subjective evaluation of a three-detector (TRIAD 88) SPECT system

    International Nuclear Information System (INIS)

    D'Souza, M.F.; Mumma, C.G.; Allen, E.W.; Phal, J.J.; Prince, J.R.

    1995-01-01

    The three-detector TRIAD 88 is a variable cylindrical FOV whole-body SPECT system designed for both brain as well as body organ imaging. The system performance was assessed in terms of physical indices and clinical quality. Measures of low contrast resolution using contrast-detail curves, high contrast resolution using LSFs and associated frequency descriptors, display characteristics, system sensitivity, energy resolution and uniformity analysis were utilized. In addition, images of Carlson phantom, Hoffman brain phantom and clinical brain images were used to compare two collimators subjectively. Measurements and calculations were obtained for two sets of parallel hole collimators, i.e., LEUR P AR and LEHR P AR. Of special interest is the consistency among the three detectors. The planar and volume sensitivities for the LEUR P AR collimator were about 58% of those of the LEHR P AR collimator. The planar spatial resolution of the two collimators differed by about 14%. The display was characterized by a logistic model H and D curve. The planar contrast-detail curves demonstrated no statistical difference in lesion detectability between the two collimator types, however SPECT phantom and clinical images demonstrated improved performance with the LEUR P AR collimator. Images of Hoffman single slice brain and Carlson phantoms and Tc-99m (HMPAO) brain images demonstrated excellent image quality. There was similarity in performance parameters of the three detector heads. 49 refs., 6 tabs., 8 figs

  15. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    International Nuclear Information System (INIS)

    Lacic, K.; Bokulic, T.; Lukac, J.; Dakovic, N.; Kusic, Z.

    1994-01-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more 'hot' and less 'cold' lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more 'hot' lesions than 4-6 hours SPECT. At the same time the number of 'cold' lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author)

  16. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Lacic, K; Bokulic, T; Lukac, J; Dakovic, N; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine

    1994-10-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more `hot` and less `cold` lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more `hot` lesions than 4-6 hours SPECT. At the same time the number of `cold` lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author).

  17. Regional cerebral blood flow assessed by single photon emission computed tomography (SPECT) in dogs with congenital portosystemic shunt and hepatic encephalopathy.

    Science.gov (United States)

    Or, Matan; Peremans, Kathelijne; Martlé, Valentine; Vandermeulen, Eva; Bosmans, Tim; Devriendt, Nausikaa; de Rooster, Hilde

    2017-02-01

    Regional cerebral blood flow (rCBF) in eight dogs with congenital portosystemic shunt (PSS) and hepatic encephalopathy (HE) was compared with rCBF in eight healthy control dogs using single photon emission computed tomography (SPECT) with a 99m technetium-hexamethylpropylene amine oxime ( 99m Tc-HMPAO) tracer. SPECT scans were abnormal in all PSS dogs. Compared to the control group, rCBF in PSS dogs was significantly decreased in the temporal lobes and increased in the subcortical (thalamic and striatal) area. Brain perfusion imaging alterations observed in the dogs with PSS and HE are similar to those in human patients with HE. These findings suggest that dogs with HE and PSS have altered perfusion of mainly the subcortical and the temporal regions of the brain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  19. Assessment of personality disorder by means of NeuroSPECT

    International Nuclear Information System (INIS)

    Mena G, Ismael; Nader N, Armando; Valdes M, Cecilia; Riquelme V, Raul

    2012-01-01

    We report on functional imaging results in 24 patients of Personality Disorder (P.D.) performed with NeuroSPECT by means of Tc99m HMPAO, in Basal state and during frontal cortical activation by means of the Wisconsin Card Sorting Test. Results demonstrate that we can make the diagnosis of P.D. when we detect significant hypoperfusion (- 2 Stand/ Deviations below the normal mean for the same age group) in the subgenual area (Area 25 of Brodmann) and in Area 24 of Brodmann, the anterior cingulated gyrus. Both areas are paradoxically more hypoperfused during the Wisconsin Test. Among patients diagnosed with P.D. NeuroSPECT can distinguish between patients of Cluster B from the ones from Cluster C in both Basal and Activation State, while Cluster A from B could be differentiated only in Basal State. On the other hand Motor Impulsivity patients could be differentiated from the Cognitive group due to paradoxical hypoperfusion in motor areas 1,2,3, and 4 of Brodmann. While the number of patients studied appears reduced these results demonstrate the capability of diagnosing Personality Disorder and also the capability to improved understanding of the subgroups of this Disorder

  20. Pulmonary function-morphologic relationships assessed by SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi

    2012-01-01

    Pulmonary single photon emission computed tomography-computed tomography (SPECT-CT) fusion images provide objective and comprehensive assessment of pulmonary function and morphology relationships at cross-sectional lungs. This article reviewed the noteworthy findings of lung pathophysiology in wide-spectral lung disorders, which have been revealed on SPECT-CT fusion images in 8 years of experience. The fusion images confirmed the fundamental pathophysiologic appearance of lung low CT attenuation caused by airway obstruction-induced hypoxic vasoconstriction and that caused by direct pulmonary arterial obstruction as in acute pulmonary thromboembolism (PTE). The fusion images showed better correlation of lung perfusion distribution with lung CT attenuation changes at lung mosaic CT attenuation (MCA) compared with regional ventilation in the wide-spectral lung disorders, indicating that lung heterogeneous perfusion distribution may be a dominant mechanism of MCA on CT. SPECT-CT angiography fusion images revealed occasional dissociation between lung perfusion defects and intravascular clots in acute PTE, indicating the importance of assessment of actual effect of intravascular colts on peripheral lung perfusion. Perfusion SPECT-CT fusion images revealed the characteristic and preferential location of pulmonary infarction in acute PTE. The fusion images showed occasional unexpected perfusion defects in normal lung areas on CT in chronic obstructive pulmonary diseases and interstitial lung diseases, indicating the ability of perfusion SPECT superior to CT for detection of mild lesions in these disorders. The fusion images showed frequent ''steal phenomenon''-induced perfusion defects extending to the surrounding normal lung of arteriovenous fistulas and those at normal lungs on CT in hepatopulmonary syndrome. Comprehensive assessment of lung function-CT morphology on fusion images will lead to more profound understanding of lung pathophysiology in wide-spectral lung

  1. The characteristics of SPECT images in childhood benign partial epilepsy

    International Nuclear Information System (INIS)

    Jia Shaowei; Liao Jianxiang; Liu Xiaoyan; Zheng Xiyuan; Qin Jiong; Pan Zhongyun; Zuo Qihua

    1998-01-01

    Purpose: To investigate childhood benign partial epilepsy (BPE) with SPECT. Methods: Double SPECT imaging was performed on 21 cases of BPE at the stage of wake (interval spike discharge) and sleep (spike discharge), under EEG monitoring. The transverse images were reconstructed after digital image subtraction. The quantitative analysis was conducted with brain flow change rate (BFCR) % mathematical model. Results: EEG monitoring demonstrated approximately normal background of 21 cases of BPE during the stage of wake, and spike discharge frequency markedly increased during the stage of sleep, 117 foci were showed by SPeCT in cases of BPE, and the average was 5.6 +- 1.6 foci/case. The characteristics of SPECT transverse images were 1) multiple foci of mirror, 2) mostly seen in Rolandic region, 3) circular symbol, 4) the radioactivity in foci decreased during the stage of wake (interval spike discharge) and increased during the stage of sleep (spike discharge). The concordance of SPECT and EEG was 93.1% (109/117 foci). The BFCR% of all epileptogenic foci exceeded normal limit (99% confidence interval). There was no correlation between the spike discharge frequency and BFCR% (r = 0.45, P>0.05). Conclusions: Regional cerebral blood flow and function were abnormal during the epileptogenic foci were discharging abnormally in BPE

  2. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    International Nuclear Information System (INIS)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R.; Lindenau, M.; Stodieck, S.; Fiehler, J.; Heese, O.

    2008-01-01

    Ictal perfusion SPECT with either 9 9mTc-hexamethylpropylene amine oxime (HMPAO) or 9 9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case

  3. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Nuclear Medicine; Lindenau, M.; Stodieck, S. [Protestant Hospital Alsterdorf, Hamburg (Germany). Dept. of Neurology and Epileptology; Fiehler, J. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Neuroradiology; Heese, O. [Univ. Medical Center Hamburg-Eppendorf (Germany). Neurological Surgery

    2008-07-01

    Ictal perfusion SPECT with either {sup 9}9mTc-hexamethylpropylene amine oxime (HMPAO) or {sup 9}9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case.

  4. Clinical Significance of Brain SPECT in Zipeprol Abusers

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Dai Ok; Kim, Jae Phil; Kim, Deog Yoon; Yang, Hyung In; Koh, Eun Mi; Kim, Kwang Won; Choi, Young Kil [Kyung Hee University College of Medicine, Seoul (Korea, Republic of)

    1993-03-15

    Drug abuse is widespread in worldwide and has been associated with neurologic complication. Zipeprol is one of drugs which been abused for psychological satisfaction in some adolescents. This agent is non-opioid antitussive agent, which is not legally considered as being capable of creating dependence or abuse liability at therapeutic serum levels. But it has been reported that acute or chronic overdose create neurologic complication such as convulsion as well as dependence. Recently we experienced six zipeprol abusers who admitted due to convulsion and variable neurologic symptoms. The aim of our study was to determine the role of Tc-99m- HMPAO brain SPECT in those patients. EEG and brain CT showed no abnormal finding, but brain SPECT showed focal or multiple perfusion abnormalities in frontal, parietal, occipital cortex, basal ganglia, thalamus and especially at temporal cortex. These results suggest that brain SPECT may be a useful diagnostic tool to evaluate the cerebral dysfunction induced by zipeprol abuse.

  5. Clinical Significance of Brain SPECT in Zipeprol Abusers

    International Nuclear Information System (INIS)

    Cho, Dai Ok; Kim, Jae Phil; Kim, Deog Yoon; Yang, Hyung In; Koh, Eun Mi; Kim, Kwang Won; Choi, Young Kil

    1993-01-01

    Drug abuse is widespread in worldwide and has been associated with neurologic complication. Zipeprol is one of drugs which been abused for psychological satisfaction in some adolescents. This agent is non-opioid antitussive agent, which is not legally considered as being capable of creating dependence or abuse liability at therapeutic serum levels. But it has been reported that acute or chronic overdose create neurologic complication such as convulsion as well as dependence. Recently we experienced six zipeprol abusers who admitted due to convulsion and variable neurologic symptoms. The aim of our study was to determine the role of Tc-99m- HMPAO brain SPECT in those patients. EEG and brain CT showed no abnormal finding, but brain SPECT showed focal or multiple perfusion abnormalities in frontal, parietal, occipital cortex, basal ganglia, thalamus and especially at temporal cortex. These results suggest that brain SPECT may be a useful diagnostic tool to evaluate the cerebral dysfunction induced by zipeprol abuse.

  6. Comparison between CT perfusion and Tc-99m ECD SPECT in the assessment of cerebrovascular reserve: a case study

    International Nuclear Information System (INIS)

    Crouch, J.; Wood, C.; Campbell, A.; McCarthy, M.; Dunne, M.; Bynevelt, M.; Lenzo, N.

    2003-01-01

    Full text: Brain perfusion is sensitively assessed by cerebral SPECT imaging utilising perfusion agents such as Tc-99m HMPAO and Tc-99m ethyl cysteinate dimer (ECD). Positron emission tomography can accurately assess and quantify brain perfusion and MRI can also be used for perfusion assessment. Both MRI and PET however are currently limited by cost and availability. A new technique utilising CT with contrast has been developed to assess and quantitate cerebral perfusion. The technique utilises arterial input information and deconvolution analysis to develop quantifiable measures of perfusion and contrast transit. The technique has been validated for acute stroke assessment and is being assessed for other possible applications. We present a case study comparison of this technique with cerebral SPECT perfusion using Tc-99m ECD in the assessment of cerebrovasular reserve. In each case, the CT and SPECT studies were performed pre- and post-acetazolamide and the SPECT study was statistically compared with a normal database utilising an automated brain perfusion statistical analysis package (NeurostatT). We discuss the correlation found between techniques, their strengths, weaknesses and possible future roles. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Individual patient dosimetry using quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Gonzalez, J.; Oliva, J.; Baum, R.; Fisher, S.

    2002-01-01

    An approach is described to provide individual patient dosimetry for routine clinical use. Accurate quantitative SPECT imaging was achieved using appropriate methods. The volume of interest (VOI) was defined semi-automatically using a fixed threshold value obtained from phantom studies. The calibration factor to convert the voxel counts from SPECT images into activity values was determine from calibrated point source using the same threshold value as in phantom studies. From selected radionuclide the dose within and outside a sphere of voxel dimension at different distances was computed through dose point-kernels to obtain a discrete absorbed dose kernel representation around the volume source with uniform activity distribution. The spatial activity distribution from SPECT imaging was convolved with this kernel representation using the discrete Fourier transform method to yield three-dimensional absorbed dose rate distribution. The accuracy of dose rates calculation was validated by software phantoms. The absorbed dose was determined by integration of the dose rate distribution for each volume of interest (VOI). Parameters for treatment optimization such as dose rate volume histograms and dose rate statistic are provided. A patient example was used to illustrate our dosimetric calculations

  8. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  9. Preliminary study on the head-injury by using SPECT with 99mTc-HMPAO

    International Nuclear Information System (INIS)

    Guan Yihui; Liu Yongchang; Lin Xiangtong

    1994-01-01

    After the acute period of head trauma some cases of patients may have some symptoms, such as headache, poor memory, vertigo, et al. In this study, among 42 patients most of whom had normal CT or MRI abnormal findings of brain perfusion imaging were seen in 33 patients (78.6%). Multiple perfusion defects were observed in some patients (13/42). These indicate that the head-injury syndrome is closely related to brain blood perfusion. authors' conclusion is that the brain SPECT is able to find out the etiology of head injury syndrome

  10. The group study of diagnostic efficacy of cerebro-vascular disease by I-123 IMP SPECT images obtained with ring type SPECT scanner

    International Nuclear Information System (INIS)

    Machida, Kikuo; Honda, Norinari; Matsumoto, Toru

    1991-01-01

    We performed two image reading experiments in order to investigate the diagnostic capability of I-123 IMP SPECT obtained by the ring type SPECT scanner in cerebro-vascular disease. Fourteen physicians diagnosed SPECT images of 55 cases with reference to clinical neurological information, first without brain XCT images and second with XCT images. Each physician detected perfusion defects and redistributions of I-123 IMP and assigned a confidence level of abnormality for these SPECT findings by means of five rating method. From results obtained by ROC analysis, we concluded as follows. (1) Generally, I-123 IMP SPECT is a stable diagnostic modality in the diagnosis of cerebro-vascular disease and the image reading of XCT had no effects on the diagnosis of SPECT on the whole of physician. (2) However, there were unnegligible differences among individuals in the detectability of findings and the effect of XCT image reading. (3) Detectability of redistribution of I-123 IMP was lower than that of perfusion defect and inter-observer variation in the diagnostic performance for redistribution was larger than that of perfusion defect. The results suggest that it is necessary to standardize diagnostic criteria among physicians for redistribution of I-123 IMP. (author)

  11. Frameless image registration of X-ray CT and SPECT by volume matching

    International Nuclear Information System (INIS)

    Tanaka, Yuko; Kihara, Tomohiko; Yui, Nobuharu; Kinoshita, Fujimi; Kamimura, Yoshitsugu; Yamada, Yoshifumi.

    1998-01-01

    Image registration of functional (SPECT) and morphological (X-ray CT/MRI) images is studied in order to improve the accuracy and the quantity of the image diagnosis. We have developed a new frameless registration method of X-ray CT and SPECT image using transmission CT image acquired for absorption correction of SPECT images. This is the automated registration method and calculates the transformation matrix between the two coordinate systems of image data by the optimization method. This registration method is based on the similar physical property of X-ray CT and transmission CT image. The three-dimensional overlap of the bone region is used for image matching. We verified by a phantom test that it can provide a good result of within two millimeters error. We also evaluated visually the accuracy of the registration method by the application study of SPECT, X-ray CT, and transmission CT head images. This method can be carried out accurately without any frames. We expect this registration method becomes an efficient tool to improve image diagnosis and medical treatment. (author)

  12. Evaluation of distance-dependent resolution compensation in brain SPECT

    International Nuclear Information System (INIS)

    Badger, D.P.; Barnden, L.R.

    2010-01-01

    Full text: Conventional SPECT reconstruction assumes that the volume of response for each collimator hole is a cylinder, but due to the finite depth of the holes, the volume of response is actually cone shaped. This leads to a loss of resolution as the distance from the collimator face is increased. If distance-dependent resolution compensation (DRC) is incorporated into an iterative reconstruction algorithm, then some of the lost resolution can be recovered (T Yokoi, H Shinohara and H Onishi. 2002, Ann Nuc Med, 16, 11-18). ORC has recently been included in some commercial reconstruction software, and the aim of this study was to assess whether the significantly increased reconstruction processing time can be justified for clinical or for research purposes. HMPAO brain scans from 104 healthy subjects were reconstructed using iterative OSEM, with and without ORC. A voxel based iterative sensitivity (VBIS) technique was used for gain correction in the scans. A Statistical Parametric Mapping (SPM) analysis found the statistical strength of the SPECT aging effect increased when the non-DRC image set was compared to the images with ORC, probably due to improvement in the imaging of partial volume effects when the interhemispheric fissure and sulci enlarge with age (L Barnden, S Behin Ain, R Kwiatek, R Casse and L Yelland. 2005, Nuc Med Comm, 26, 497-503). It was concluded that the use of ORC is justified for research purposes, but may not be for routine clinical use. (author)

  13. The effect of Compton scattering on quantitative SPECT imaging

    International Nuclear Information System (INIS)

    Beck, J.W.; Jaszczak, R.J.; Starmer, C.F.

    1982-01-01

    A Monte Carlo code has been developed to simulate the response of a SPECT system. The accuracy of the code has been verified and has been used in this research to study and illustrate the effects of Compton scatter on quantitative SPECT measurements. The effects of Compton scattered radiation on gamma camera response have been discussed by several authors, and will be extended to rotating gamma camera SPECT systems. The unique feature of this research includes the pictorial illustration of the Compton scattered and the unscattered components of the photopeak data on SPECT imaging by simulating phantom studies with and without Compton scatter

  14. Cortical region of interest definition on SPECT brain images using X-ray CT registration

    Energy Technology Data Exchange (ETDEWEB)

    Tzourio, N.; Sutton, D. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot); Joliot, M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot INSERM, Orsay (France)); Mazoyer, B.M. (Commissariat a l' Energie Atomique, Orsay (France). Service Hospitalier Frederic Joliot Antenne d' Information Medicale, C.H.U. Bichat, Paris (France)); Charlot, V. (Hopital Louis Mourier, Colombes (France). Service de Psychiatrie); Salamon, G. (CHU La Timone, Marseille (France). Service de Neuroradiologie)

    1992-11-01

    We present a method for brain single photon emission computed tomography (SPECT) analysis based on individual registration of anatomical (CT) and functional ([sup 133]Xe regional cerebral blood flow) images and on the definition of three-dimensional functional regions of interest. Registration of CT and SPECT is performed through adjustment of CT-defined cortex limits to the SPECT image. Regions are defined by sectioning a cortical ribbon on the CT images, copied over the SPECT images and pooled through slices to give 3D cortical regions of interest. The proposed method shows good intra- and interobserver reproducibility (regional intraclass correlation coefficient [approx equal]0.98), and good accuracy in terms of repositioning ([approx equal]3.5 mm) as compared to the SPECT image resolution (14 mm). The method should be particularly useful for analysing SPECT studies when variations in brain anatomy (normal or abnormal) must be accounted for. (orig.).

  15. Hybrid SPECT/CT imaging in neurology.

    Science.gov (United States)

    Ciarmiello, Andrea; Giovannini, Elisabetta; Meniconi, Martina; Cuccurullo, Vincenzo; Gaeta, Maria Chiara

    2014-01-01

    In recent years, the SPECT/CT hybrid modality has led to a rapid development of imaging techniques in nuclear medicine, opening new perspectives for imaging staff and patients as well. However, while, the clinical role of positron emission tomography-computed tomography (PET-CT) is well consolidated, the diffusion and the consequent value of single-photon emission tomography-computed tomography (SPECT-CT) has yet to be weighed, Hence, there is a need for a careful analysis, comparing the "potential" benefits of the hybrid modality with the "established" ones of the standalone machine. The aim of this article is to analyze the impact of this hybrid tool on the diagnosis of diseases of the central nervous system, comparing strengths and weaknesses of both modalities through the use of SWOT analysis.

  16. Role of I-123-iomazenil SPEDT imaging in drug resistant epilepsy with complex partial seizures

    Energy Technology Data Exchange (ETDEWEB)

    Sjoeholm, H.; Rosen, I.; Elmqvist, D. [Univ. Hospital, Dept. of Clinical Neurophysiology, Lund (Sweden)

    1995-07-01

    Fifteen patients with therapy resistant partial complex seizures with no structural lesions were examined interictally with 123-I-IOMAXENIL SPECT for measurement of benzodiazepine receptor distribution and with 99m-Tc-HMPAO SPEDT for measurement of cerebral blood flow distribution. Regional abnormalities were correlated with the seizure onset patterns in EEG later recorded with implanted subdural strips. SPECT scans were made immediately after and at 1 and 2 h after intravenous injection of 123-I-Iomaxenil. During that time there was a continuous change from an immediate flow-related distribution toward a more specific receptor distribution. The decay of radioactivity of I-123 in the brain was linear over time. Two patients on benzodiazepine treatment showed much faster elimination and showed no focal abnormalities. Eight patients with clear-cut unifocal seizure onset showed concordant focal benzodiazepine defects. These patients showed a progressive focus/homotopic non-focus enhancement over time much larger than the HMPAO scans in the same patients. Also the estimated focal area of abnormality was more restricted in the Iomazenil scans than in HMPAO scans. Five patients had more complex seizure onset patterns. In these patients a mismatch between the locations of abnormalities in Iomaxenil and HMPAO scans were often found but benzodiazepine receptor abnormalities were more circumscribed also in these patients. The results suggest that 123-I-Iomazenil SPECT is more useful than 99mTc-HMPAO SPECT when applied interictally in patients with partial complex epilepsy, since in addition to demonstrate the hemispheric laterality of the epileptogenic zone, 123-I-Iomazenil appears to indicate its anatomical location with higher confidence, which could be of practical value for positioning of intracranial EEG electrodes. (au) 36 refs.

  17. Benign versus malignant osseous lesions in spine: differentiation by means of bone SPECT/CT fused image

    International Nuclear Information System (INIS)

    Yao Zhiming; Qu Wanying

    2004-01-01

    This study compared the efficiency of SPECT-CT fused image with planar bone scan, bone SPECT and CT in differentiating malignant from benign lesions and detecting metastases to the spine. Methods. Total 144 patients with spinal lesions underwent planar bone scan (WB), single photon tomography (SPECT), CT and SPECT-CT fused image by a SPECT/CT system. The malignant or benign nature of lesions was proved by radiological Methods, histological findings, 6-24 month follow-up, or all of these. The diagnostic results was divided into 4 types, i.e., normal, benign, doubtful malignant and malignant. Results. There were 137 malignant and 252 benign lesions in 144 patients, respectively. The percentages of doubtful malignant diagnosed by WB, SPECT, CT and fused image are 22.6%, 5.1%, 9.5% and 0%, respectively, p < 0.01-0.001, except for the comparison between the percentages of SPECT and CT. Sensitivities in detection of malignant lesions by WB, SPECT, CT and fused image are 75.2%, 94.2%, 96.6% and 99.3%, respectively, P < 0.001, excepting for the comparisons between those of SPECT and CT, and between those of CT and fused image. The sensitivities m detection of benign lesions by WB, SPECT, CT and fused image are, 56.7%, 86.5%, 90.1% and 96.8%, respectively, P < 0.005 - 0.001, excepting for the comparison between those of SPECT and CT. The specificities in detection of maliganant lesions by WB, SPECT, CT and fused image are 70.6%, 88.9%, 97.2% and 97.6%, respectively, P < 0.001, excepting for the comparison between those of CT and fused image. Conclusion. Bone SPECT-CT fused image has highest diagnostic and differentiating diagnostic values in detection of spinal abnormalities over the planar bone scanning and SPECT. The CT by present SPECT/CT system can complement planar bone scanning and SPECT and is clinically valuable in detection of spinal abnormalities. (authors)

  18. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Kamoya, Masatoshi

    2001-01-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  19. Effects of typical antipsychotic, haloperidol on regional cerebral blood flow in drug-naive schizophrenic patients-study with 99mTc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kamoya, Masatoshi [Kanazawa Medical Univ., Ishikawa (Japan)

    2001-03-01

    For the purpose of examining antipsychotic action of haloperidol (HPD), effects of chronic perioral administration of HPD 4.5 mg/day on regional cerebral blood flow (rCBF) with 99mTc-HMPAO SPECT were investigated in 12 drug-naive schizophrenic patients with acute hallucinatory and delusional state. Further, the SPECT examinations were performed on 20 normal adult volunteers to investigate differences in rCBFs between schizophrenics and the normal subjects. Results are itemized as follows. The rCBF values were significantly increased in the bilateral superior and middle frontal, cingulate, middle temporal, pre-and post-central gyri, the left superior temporal gyrus, the bilateral inferior parietal lobule, and the bilateral hippocampal and thalamic cortices in comparison between normal subjects and before the HPD dose in schizophrenics. However, the rCBF values after the HPD dose showed significant increases only in the bilateral pre-and post-central gyri in comparison with the normal subjects. The rCBF values were significantly decreased in the bilateral superior, middle and inferior frontal, superior and middle temporal gyri, and the left insular gyrus after the HPD dose in comparison with before the HPD dose. The psychiatric assessment with PANSS showed an improvement of positive symptoms consisting of auditory hallucination and delusions after the HPD dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the HPD dose showed positive correlations between the right inferior frontal gyrus and auditory hallucination or positive symptoms, between the right superior temporal gyrus, left thalamus and delusions, and between the left thalamus, insular gyrus and negative symptoms. These results suggest that acute drug-naive schizophrenic patients have widespread cortico-subcortical energic hypermetabolism and HPD reduces the hypermetabolism, leading to whole normalized brain metabolism, in particular with the larger region

  20. The Performance of Ictal Brain SPECT for Localizing Epileptogenic Foci in Temporal Lobe epilepsies

    International Nuclear Information System (INIS)

    Kim, Eun Sil; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Chang, Kee Hyun; Lee, Sang Kun; Chung, Chun Kee

    1995-01-01

    Anterior temporal lobectomy has become a widely used respective surgery in patients with medically intractable temporal lobe epilepsies. Prerequisites of this resection include the accurate localization of the epileptogenic focus and the determination that the proposed resection would not result in unacceptable postoperative memory or language deficits. The purpose of this study was to evaluate the performance of ictal SPECT compared to MRI findings for localization of epileptogenic foci in this group of patients. 11 patients who had been anterior temporal oral lobectomy were evaluated with ictal 99m Tc-HMPAO SPECT and MRI. MRI showed 8/11(73%) concordant lesion to the side of surgery and ictal SPECT also showed 8/11(73%) concordant hyperperfusion. In 3 cases with incorrect or nonlocalizing findings of MRI, ictal SPECT showed concordant hyperperfusion. In 2 cases confirmed by pre-resectional invasive EEG, MRI showed bilateral and contralateral lesion but ictal SPECT showed concordant hyperperfusion. 3 delayed injection of ictal SPECT showed discordant hyperperfusion. Thus, ictal SPECT was a useful method for localizing epileptogenic foci in temporal lobe epilepsies and appeared complementay to MRI.

  1. Regional cerebral blood flow changes as assessed by 99m-Tc-HMPAO SPECT in 70 Unipolar Depressed patients at rest

    International Nuclear Information System (INIS)

    Pagani, M.M.E.; Sanchez-Crespo, A.; Jonsson, C.; Jacobsson, H.; Waegner, A.; Larsson, S.A.; Gardner, A.; Haellstroem, T.; Salmaso, D.

    2002-01-01

    Aim: Alterations in excitatory or inhibitory signals between cortical and sub-cortical regions in patients with unipolar depression (MDD) may be assessed by investigating changes in regional cerebral blood flow (rCBF). Regions with abnormal metabolic activity might participate in neural networks and affect the rCBF distribution in functionally connected structures. The aim of this study was to identify the brain regions showing rCBF changes in MDD by means of SPECT and Principal Component Analysis (PCA). Materials and Methods: The rCBF distributions in 70 MDD and 66 control (CTR) subjects, at rest, were compared. 99m Tc-HMPAO SPECT, using a three-headed gamma camera, was performed and the uptake in 27 functional bilateral sub-volumes of the brain was assessed by a standardised digitalised brain atlas. Data were grouped into functional regions by means of PCA analysis performed on all 136 individuals. Analysis of variance (ANOVA) was used to test the significance of the differences in flow in such functional regions. Results: In the global analysis, rCBF significantly differed between groups (0.02). There were also significant hemispheres x groups interaction (p<0.003) and gender difference (p=0.003), with right hemisphere rCBF specifically increased in MDD and females showing a higher CBF. PCA identified 11 anatomo-functional regions that interacted with groups (p<0.001) and gender (p<0.001). As compared to CTR, MDD rCBF increased, bilaterally, in the right associative temporo-parietal cortex (p<0.007), in right frontal cortex and prefrontal cortex (p=0.002), in the temporal poles (p<0.03) and in thalamus and basal ganglia (p<0.001). Conclusions: Higher rCBF in MDD at rest was found in 4 clusters of regions sharing close anatomical and functional relationships. These regions represented large parts of the right hemisphere and the downstream central structures. These findings confirm rCBF changes in unipolar depressive disorders, suggest mutual rCBF relationships

  2. A methodology for generating normal and pathological brain perfusion SPECT images for evaluation of MRI/SPECT fusion methods: application in epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Grova, C [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Jannin, P [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Biraben, A [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Buvat, I [INSERM U494, CHU Pitie Salpetriere, Paris (France); Benali, H [INSERM U494, CHU Pitie Salpetriere, Paris (France); Bernard, A M [Service de Medecine Nucleaire, Centre Eugene Marquis, Rennes (France); Scarabin, J M [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France); Gibaud, B [Laboratoire IDM, Faculte de Medecine, Universite de Rennes 1, Rennes (France)

    2003-12-21

    Quantitative evaluation of brain MRI/SPECT fusion methods for normal and in particular pathological datasets is difficult, due to the frequent lack of relevant ground truth. We propose a methodology to generate MRI and SPECT datasets dedicated to the evaluation of MRI/SPECT fusion methods and illustrate the method when dealing with ictal SPECT. The method consists in generating normal or pathological SPECT data perfectly aligned with a high-resolution 3D T1-weighted MRI using realistic Monte Carlo simulations that closely reproduce the response of a SPECT imaging system. Anatomical input data for the SPECT simulations are obtained from this 3D T1-weighted MRI, while functional input data result from an inter-individual analysis of anatomically standardized SPECT data. The method makes it possible to control the 'brain perfusion' function by proposing a theoretical model of brain perfusion from measurements performed on real SPECT images. Our method provides an absolute gold standard for assessing MRI/SPECT registration method accuracy since, by construction, the SPECT data are perfectly registered with the MRI data. The proposed methodology has been applied to create a theoretical model of normal brain perfusion and ictal brain perfusion characteristic of mesial temporal lobe epilepsy. To approach realistic and unbiased perfusion models, real SPECT data were corrected for uniform attenuation, scatter and partial volume effect. An anatomic standardization was used to account for anatomic variability between subjects. Realistic simulations of normal and ictal SPECT deduced from these perfusion models are presented. The comparison of real and simulated SPECT images showed relative differences in regional activity concentration of less than 20% in most anatomical structures, for both normal and ictal data, suggesting realistic models of perfusion distributions for evaluation purposes. Inter-hemispheric asymmetry coefficients measured on simulated data were

  3. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  4. Adaptive Angular Sampling for SPECT Imaging

    OpenAIRE

    Li, Nan; Meng, Ling-Jian

    2011-01-01

    This paper presents an analytical approach for performing adaptive angular sampling in single photon emission computed tomography (SPECT) imaging. It allows for a rapid determination of the optimum sampling strategy that minimizes image variance in regions-of-interest (ROIs). The proposed method consists of three key components: (a) a set of close-form equations for evaluating image variance and resolution attainable with a given sampling strategy, (b) a gradient-based algor...

  5. Influence of void on image quality of industrial SPECT

    International Nuclear Information System (INIS)

    Park, J G; Jung, S H; Kim, J B; Moon, J; Kim, C H

    2013-01-01

    Industrial single photon emission computed tomography (SPECT) is a promising technique to determine the dynamic behavior of industrial process media and has been developed in the Korea Atomic Energy Research Institute. The present study evaluated the influence of a void, which is presence in multiphase reactors of industrial process, on the image quality of an industrial SPECT. The results are very encouraging; that is, the performance of the industrial SPECT system is little influenced by the presence of a void, which means that industrial SPECT is an appropriate tool to estimate the dynamic characteristics of the process media in a water-air phase bubble column with a static gas sparger

  6. 3D composite image, 3D MRI, 3D SPECT, hydrocephalus

    International Nuclear Information System (INIS)

    Mito, T.; Shibata, I.; Sugo, N.; Takano, M.; Takahashi, H.

    2002-01-01

    The three-dimensional (3D)SPECT imaging technique we have studied and published for the past several years is an analytical tool that permits visual expression of the cerebral circulation profile in various cerebral diseases. The greatest drawback of SPECT is that the limitation on precision of spacial resolution makes intracranial localization impossible. In 3D SPECT imaging, intracranial volume and morphology may vary with the threshold established. To solve this problem, we have produced complimentarily combined SPECT and helical-CT 3D images by means of general-purpose visualization software for intracranial localization. In hydrocephalus, however, the key subject to be studied is the profile of cerebral circulation around the ventricles of the brain. This suggests that, for displaying the cerebral ventricles in three dimensions, CT is a difficult technique whereas MRI is more useful. For this reason, we attempted to establish the profile of cerebral circulation around the cerebral ventricles by the production of combined 3D images of SPECT and MRI. In patients who had shunt surgery for hydrocephalus, a difference between pre- and postoperative cerebral circulation profiles was assessed by a voxel distribution curve, 3D SPECT images, and combined 3D SPECT and MRI images. As the shunt system in this study, an Orbis-Sigma valve of the automatic cerebrospinal fluid volume adjustment type was used in place of the variable pressure type Medos valve currently in use, because this device requires frequent changes in pressure and a change in pressure may be detected after MRI procedure. The SPECT apparatus used was PRISM3000 of the three-detector type, and 123I-IMP was used as the radionuclide in a dose of 222 MBq. MRI data were collected with an MAGNEXa+2 with a magnetic flux density of 0.5 tesla under the following conditions: field echo; TR 50 msec; TE, 10 msec; flip, 30ueK; 1 NEX; FOV, 23 cm; 1-mm slices; and gapless. 3D images are produced on the workstation TITAN

  7. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    Science.gov (United States)

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p IQ-SPECT with and without SCAC was also good (r = 0.907 and p IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating characteristic analysis were 0.77, 0.80, and 0.86 for conventional SPECT, IQ-SPECT without SCAC, and IQ-SPECT with SCAC, respectively (p = n.s. for each comparison). When appropriate NDBs were used, the diagnostic performance of 201 Tl IQ-SPECT

  8. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  9. Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT: A Phantom Study.

    Directory of Open Access Journals (Sweden)

    Oliver S Grosser

    Full Text Available Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT or positron emission tomography (PET with computed tomography (CT. Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic applications. It was the aim of this study to investigate the influence of an iterative CT image reconstruction algorithm (ASIR on the image quality of the low-dose CT images.Examinations were performed with a SPECT-CT scanner with standardized CT and SPECT-phantom geometries and CT protocols with systematically reduced X-ray tube currents. Analyses included image quality with respect to photon flux. Results were compared to the standard FBP reconstructed images. The general impact of the CT-based attenuation maps used during SPECT reconstruction was examined for two SPECT phantoms. Using ASIR for image reconstructions, image noise was reduced compared to FBP reconstructions for the same X-ray tube current. The Hounsfield unit (HU values reconstructed by ASIR were correlated to the FBP HU values(R2 ≥ 0.88 and the contrast-to-noise ratio (CNR was improved by ASIR. However, for a phantom with increased attenuation, the HU values shifted for low X-ray tube currents I ≤ 60 mA (p ≤ 0.04. In addition, the shift of the HU values was observed within the attenuation corrected SPECT images for very low X-ray tube currents (I ≤ 20 mA, p ≤ 0.001.In general, the decrease in X-ray tube current up to 30 mA in combination with ASIR led to a reduction of CT-related radiation exposure without a significant decrease in image quality.

  10. State-of-the-art of small animal imaging with high-resolution SPECT

    International Nuclear Information System (INIS)

    Nikolaus, S.; Wirrwar, A.; Antke, C.; Kley, K.; Mueller, H.W.

    2005-01-01

    During the recent years, in vivo imaging of small animals using SPECT has become of growing relevance. Along with the development of dedicated high-resolution small animal SPECT cameras, an increasing number of conventional clinical scanners has been equipped with single or multipinhole collimators. This paper reviews the small animal tomographs, which are operating at present and compares their performance characteristics. Furthermore, we describe the in vivo imaging studies, which have been performed so far with the individual scanners and survey current approaches to optimize molecular imaging with small animal SPECT. (orig.)

  11. Interictal rCBF SPECT, MRI and Surgical Outcome of Intractable Temporal Lobe Epilepsy

    International Nuclear Information System (INIS)

    Zeon, Seok Kil; Joo, Yang Goo; Lee, Sang Doe; Son, Eun Ik; Lee, Young Hwan

    1994-01-01

    Interictal single photon emission computed tomography of regional cerebral blood flow (rCBF SPECT) in 18 intractable temporal lobe epilepsy patients (8 male and 10 female patients: average 23.5 years old) were compared with 2.0 T magnetic resonance imaging (MRI). And surgical outcome was analysed with the findings, symptom duration and lateralization of temporal lobe. Preoperatively rCRF SPECT was done in all 18 patients with intravenous injection of 740 MRq 99 m T c-HMPAO. MRI was also done preoperatively in 13 patients. Surgical outcome was classified by Engel's outcome classification (four part classification recommended at the first Palm Desert conference). rCRF SPECT detected correctly lateralising abnormality of temporal lobe hypoperfusion in 13/ 18 (72.2%), contralateral temporal lobe hypoperfusion in 2/18 (11.1%) and showed no definite abnormality in 3/18 (16.7%). The positive predictive value of unilateral temporal lobe hypoperfusion was 87%. MRI detected correct localising abnormality in 8/13 (61.5%), such as hippocampal atrophy (7/13), asymmetric temporal horn (6/13), anterior temporal lobe atrophy (1/13), increased signal intensity from hippocampus (1/13) and calcific density (1/13), and no abnormal finding was noted in 5/13 (38.5%), There was no false positive findings and the positive predictive value of MRI was 100%, Only 2 cases showed same lateralization findings in rCBF SPECT and MRI. There was no significant correlation between symptom duration and no abnormal findings on SPECT or MRI. Surgical outcome showed class I in 15/18 (83.3%), and class II in 2/18 (11.1%). One case of no abnormal finding in both SPECT and MRI showed class III surgical outcome. No class IV surgical out.come was noted. Surgical outcome, lateralization of epileptic focus in temporal lobe and abnormal findings in rCBR SPECT or MRI were not significantly correlated.

  12. DMSA SPECT imaging using oblique reconstruction in a paediatric population - benefits and technical considerations

    International Nuclear Information System (INIS)

    Parsons, G.; Ford, M.; Crisp, J.; Bernard, E.; Howman-Giles, R.

    1997-01-01

    Full text: DMSA renal scans are frequently requested for the diagnosis and follow-up of acute pyelonephritis and cortical scarring. This study was designed to:- 1. evaluate oblique reconstruction of DMSA SPECT over standard plane reconstruction and planar imaging; and 2. report on the technical aspects important in obtaining high quality DMSA SPECT, particularly in neonates. Over seven months, 210/231 (91 %) of DMSA scans were performed with SPECT on children from age nine days to 16 years, the median age being 2.5 years. 65 patients (31 %) were under one year and 39 (18%) were under six months. Planar and SPECT imaging with standard plane reconstruction and oblique reorientation was performed on the Siemens triple-headed gamma camera. High quality SPECT images were obtained on the smallest babies using a paediatric palette, and were of comparable quality to those of older children. At the time of reporting, the nuclear medicine physician assessed the diagnostic value of the three types of date presented: (1) planar images; (2) standard plane SPECT reconstruction; and (3) oblique SPECT reconstruction. Cortical defects were identified separately for upper, middle and lower poles. Three physicians concluded that high quality SPECT is superior to planar images when assessing the renal cortex. In addition, oblique reorientation is superior to standard reconstruction, particularly at the upper and lower poles. SPECT is now performed routinely on patients of all ages, and the oblique sagittal and coronal reorientation is now used in place of the standard reconstruction

  13. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  14. Different uptake of 99mTc-ECD adn 99mTc-HMPAO in the same brains: analysis by statistical parametric mapping.

    Science.gov (United States)

    Hyun, Y; Lee, J S; Rha, J H; Lee, I K; Ha, C K; Lee, D S

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer (99mTc-ECD) and technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62+/-12 years) using 99mTc-ECD and 99mTc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for 99mTc-ECD and 99mTc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the 99mTc-ECD and 99mTc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either 99mTc-ECD or 99mTc-HMPAO SPET images. SPM analysis revealed significantly different uptake of 99mTc-ECD and 99mTc-HMPAO in the same brains. On the 99mTc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the 99mTc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with 99mTc-ECD and 99mTc-HMPAO.

  15. The clinical application of SPECT myocardial perfusion imaging with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Dong Weiyu

    1992-01-01

    This paper reported 182 SPECT myocardial perfusion images with China made 99m Tc-MIBI and were compared with ECG and UCG. The sensitivity of SPECT in ischemic were 91.2% and was higher than ECG (74.9%)and UCG (61.8%) (P < 0.01). And its specificity, accuracy and positive predictive rate were 78.3%, 90% and 97% respectively. Besides 9 cases have reverse distribution after exercise and rest images. In some ICD patients had shown their SPECT images, the perfusion defects in exercise as well as in rest image

  16. SPECT/CT imaging in children with papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Kim, Hwa-Young; Gelfand, Michael J.; Sharp, Susan E.

    2011-01-01

    SPECT/CT improves localization of single photon-emitting radiopharmaceuticals. To determine the utility of SPECT/CT in children with papillary thyroid carcinoma. 20 SPECT/CT and planar studies were reviewed in 13 children with papillary thyroid carcinoma after total thyroidectomy. Seven studies used I-123 and 13 used I-131, after elevating TSH by T4 deprivation or intramuscular thyrotropin alfa. Eight children had one study and five children had two to four studies. Studies were performed at initial post-total thyroidectomy evaluation, follow-up and after I-131 treatment doses. SPECT/CT was performed with a diagnostic-quality CT unit in 13 studies and a localization-only CT unit in 7. Stimulated thyroglobulin was measured (except in 2 cases with anti-thyroglobulin antibodies). In 13 studies, neck activity was present but poorly localized on planar imaging; all foci of uptake were precisely localized by SPECT/CT. Two additional foci of neck uptake were found on SPECT/CT. SPECT/CT differentiated high neck uptake from facial activity. In six studies (four children), neck uptake was identified as benign by SPECT/CT (three thyroglossal duct remnants, one skin contamination, two by precise anatomical CT localization). In two children, SPECT/CT supported a decision not to treat with I-131. When SPECT/CT was unable to identify focal uptake as benign, stimulated thyroglobulin measurements were valuable. In three of 13 studies with neck uptake, SPECT/CT provided no useful additional information. SPECT/CT precisely localizes neck iodine uptake. In small numbers of patients, treatment is affected. SPECT/CT should be used when available in thyroid carcinoma patients. (orig.)

  17. Improvements in SPECT technology for cerebral imaging

    International Nuclear Information System (INIS)

    Esser, P.D.

    1985-01-01

    Advancement in three major areas of SPECT (single photon emission computed tomography) technology have resulted in improved image quality for cerebral studies. In the first area, single-crystal camera electronics, extensive use of microprocessors, custom digital circuitry, an data bus architecture have allowed precise external control of all gantry motions and improved signal processing. The new digital circuitry permits energy, uniformity, and linearity corrections to be an integral part of the processing electronics. Calibration of these correlations is controlled by algorithms stored in the camera's memory. The second area of improved SPECT technology is camera collimation and related imaging techniques. In this area, system resolution has been improved without loss of sensitivity by decreasing the air gap between patient and collimator surface. Since cerebral studies characteristically image high-contrast regions less than 1 cm in size, image quality has been improved by increasing collimator resolution even at the expense of sensitivity. Increased resolution also improved image contrast for studies using 123 I-labeled pharmaceuticals with 3% to 4% 124 I contamination. 65 references

  18. Bull's-eye map of myocardial perfusion MR imaging. Comparison with SPECT

    International Nuclear Information System (INIS)

    Nomura, Yukihiro; Nanjo, Shuji; Yamazaki, Junichi; Yoshikawa, Kohki; Inoue, Yusuke

    2003-01-01

    When diagnosing heart disease, chest roentgenograms, ultrasonography, single-photon emission computed tomography (SPECT), and coronary arteriography are usually performed. Magnetic resonance (MR) imaging is not widely used for evaluating heart disease. Recent technological progress has allowed high quality images of the heart to be reliably obtained. A routine MR study taking about 30-40 minutes can provide a large amount of diagnostic information, such as cardiac structure, function, perfusion, and myocardial viability. The analysis software that can offer Bull's-eye maps from myocardial perfusion images has recently become commercially available. In this study, the characteristics of Bull's-eye mapping of MR imaging is compared with that of Bull's-eye mapping of SPECT using the same heart phantom. The difference in the image quality of the Bull's-eye maps was evaluated among the receiver coils of MR imaging. On Bull's-eye maps from both MR imaging and SPECT, decreased signal intensity was noted in the posterolateral wall. The degree of decrease in the signal of the MR imaging was more prominent than of SPECT. The decrease was severe for the general-purpose receive-only flexible (GPFLEX) coil, moderate for the cardiac and TORSO coil, and slight for the body coil. In the selection of a coil, it is necessary to take into consideration the trade-off between the distribution of signal intensity and the signal-to-noise ratio (SNR). (author)

  19. Metabolic imaging using SPECT

    International Nuclear Information System (INIS)

    Taki, Junichi; Matsunari, Ichiro

    2007-01-01

    In normal condition, the heart obtains more than two-thirds of its energy from the oxidative metabolism of long chain fatty acids, although a wide variety of substrates such as glucose, lactate, ketone bodies and amino acids are also utilised. In ischaemic myocardium, on the other hand, oxidative metabolism of free fatty acid is suppressed and anaerobic glucose metabolism plays a major role in residual oxidative metabolism. Therefore, metabolic imaging can be an important technique for the assessment of various cardiac diseases and conditions. In SPECT, several iodinated fatty acid traces have been introduced and studied. Of these, 123 I-labelled 15-(p-iodophenyl)3-R, S-methylpentadecanoic acid (BMIPP) has been the most commonly used tracer in clinical studies, especially in some of the European countries and Japan. In this review article, several fatty acid tracers for SPECT are characterised, and the mechanism of uptake and clinical utility of BMIPP are discussed in detail. (orig.)

  20. Clinical usefulness of scatter and attenuation correction for brain single photon emission computed tomography (SPECT) in pediatrics

    International Nuclear Information System (INIS)

    Adachi, Itaru; Doi, Kenji; Komori, Tsuyoshi; Hou, Nobuyoshi; Tabuchi, Koujirou; Matsui, Ritsuo; Sueyoshi, Kouzou; Utsunomiya, Keita; Narabayashi, Isamu

    1998-01-01

    This investigation was undertaken to study clinical usefulness of scatter and attenuation correction (SAC) of brain SPECT in infants to compare the standard reconstruction (STD). The brain SPECT was performed in 31 patients with 19 epilepsy, 5 cerebro-vascular disease, 2 brain tumor, 3 meningitis, 1 hydrocephalus and psychosis (mean age 5.0±4.9 years old). Many patients was necessary to be injected sedatives for restraining body motion after Technetium-99m hexamethylpropylene amine oxime ( 99m Tc-HMPAO) was injected at the convulsion or rest. Brain SPECT data were acquired with triple detector gamma camera (GCA-9300 Toshiba Japan). These data were reconstructed by filtered backprojection after the raw data were corrected by triple energy windows method of scatter correction and Chang filtered method of attenuation correction. The same data was reconstructed by filtered backprojection without these corrections. Both SAC and STD SPECT images were analyzed by the visual interpretation. The uptake ratio of cerebral basal nuclei was calculated by the counts of the thalamus or lenticular nuclei divided by the cortex. All images of SAC method were excellent than that of STD method. The thalamic uptake ratio in SAC method was higher than that of STD method (1.22±0.09>0.87±0.22 p 1.02±0.16 p<0.01). Transmission scan is the most suitable method of absorption correction. But the transmission scan is not adequate for examination of children, because this scan needs a lot of time and the infants are exposed by the line source radioisotope. It was concluded that these scatter and absorption corrections were most suitable method for brain SPECT in pediatrics. (author)

  1. Triangular SPECT system for 3-D total organ volume imaging: Design concept and preliminary imaging results

    International Nuclear Information System (INIS)

    Lim, C.B.; Anderson, J.; Covic, J.

    1985-01-01

    SPECT systems based on 2-D detectors for projection data collection and filtered back-projection image reconstruction have the potential for true 3-D imaging, providing contiguous slice images in any orientation. Anger camera-based SPECT systems have the natural advantage supporting planar imaging clinical procedures. However, current systems suffer from two drawbacks; poor utilization of emitted photons, and inadequate system design for SPECT. A SPECT system consisting of three rectangular cameras with radial translation would offer the variable cylindrical FOV of 25 cm to 40 cm diameter allowing close detector access to the object. This system would provide optimized imaging for both brain and body organs in terms of sensitivity and resolution. For brain imaging a tight detector triangle with fan beam collimation, matching detector UFOV to the head, allows full 2 π utilization of emitted photons, resulting in >4 times sensitivity increase over the single detector system. Minification of intrinsic detector resolution in fan beam collimation further improves system resolution. For body organ imaging the three detectors with parallel hole collimators, rotating in non-circular orbit, provide both improved resolution and three-fold sensitivity increase. Practical challenges lie in ensuring perfect image overlap from three detectors without resolution degradation and artifact generation in order to benefit from the above improvements. An experimental system has been developed to test the above imaging concept and we have successfully demonstrated the superior image quality of the overlapped images. Design concept will be presented with preliminary imaging results

  2. Infective endocarditis detection through SPECT/CT images digital processing

    Science.gov (United States)

    Moreno, Albino; Valdés, Raquel; Jiménez, Luis; Vallejo, Enrique; Hernández, Salvador; Soto, Gabriel

    2014-03-01

    Infective endocarditis (IE) is a difficult-to-diagnose pathology, since its manifestation in patients is highly variable. In this work, it was proposed a semiautomatic algorithm based on SPECT images digital processing for the detection of IE using a CT images volume as a spatial reference. The heart/lung rate was calculated using the SPECT images information. There were no statistically significant differences between the heart/lung rates values of a group of patients diagnosed with IE (2.62+/-0.47) and a group of healthy or control subjects (2.84+/-0.68). However, it is necessary to increase the study sample of both the individuals diagnosed with IE and the control group subjects, as well as to improve the images quality.

  3. Thoracic and abdominal SPECT imaging in systemic amyloidosis in identifying multiorgan involvement

    International Nuclear Information System (INIS)

    Wellman, H.N.; Benson, M.D.; Park, H.M.; Siddiqui, A.R.; Krepshaw, J.D.

    1988-01-01

    Thirty-three patients with systemic amyloidosis have been studied. Thoracic single photon emission computed tomography (SPECT) for myocardial involvement and skeletal imaging were performed with Tc-99m PYP, and abdominal SPECT with TcS colloid. Myocardial wall involvement was easily discernible with SPECT in 17 cases, and in many with normal ultrasonography. PYP uptake was also observed in liver (five patients), kidneys (four patients), and soft tissues (two patients). Most patients had widespread degenerative joint disease. With TcS colloid, intrinsic liver abnormalities were found in four patients, hepatomegaly in seven, and splenic infiltration in two. Nuclear SPECT and planar imaging characterize the distribution of systemic amyloidosis in organs, distribution not readily identified with other diagnostic modalities

  4. SPECT and PET in cerebrovascular diseases. SPECT und PET bei cerebrovaskulaeren Erkrankungen

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, W.H. (Herzzentrum Nordrhein-Westfalen, Bad Oeynhausen (Germany). Inst. fuer Nuklearmedizin)

    1993-02-01

    Investigations using recently emerged perfusion tracers for SPECT, Tc-99m-HMPAO in particular, and studies of local glucose metabolism and oxygen utilisation with PET have deepened our knowledge of the pathophysiology in development and in the sequel of stroke. Studies of local cerebral blood flow and cerebrovascular reserve capacity are indicated in case of neurological symptoms suspected to be caused by transient ischemic attacks or in case of significant narrowing of the cerebral arteries. PET investigations of local metabolism (at the present state) are indicated in patients with incompleted stroke or with infarction and extended ischemic border zone. The differential diagnosis between multi-infarct-dementia and primarily neurodegenerative dementias is facilitated, in some individuals, by the characteristic topography of reduced flow. (orig./MG).

  5. Two-dimensional filtering of SPECT images using the Metz and Wiener filters

    International Nuclear Information System (INIS)

    King, M.A.; Schwinger, R.B.; Penney, B.C.; Doherty, P.W.

    1984-01-01

    Presently, single photon emission computed tomographic (SPECT) images are usually reconstructed by arbitrarily selecting a one-dimensional ''window'' function for use in reconstruction. A better method would be to automatically choose among a family of two-dimensional image restoration filters in such a way as to produce ''optimum'' image quality. Two-dimensional image processing techniques offer the advantages of a larger statistical sampling of the data for better noise reduction, and two-dimensional image deconvolution to correct for blurring during acquisition. An investigation of two such ''optimal'' digital image restoration techniques (the count-dependent Metz filter and the Wiener filter) was made. They were applied both as two-dimensional ''window'' functions for preprocessing SPECT images, and for filtering reconstructed images. Their performance was compared by measuring image contrast and per cent fractional standard deviation (% FSD) in multiple-acquisitions of the Jaszczak SPECT phantom at two different count levels. A statistically significant increase in image contrast and decrease in % FSD was observed with these techniques when compared to the results of reconstruction with a ramp filter. The adaptability of the techniques was manifested in a lesser % reduction in % FSD at the high count level coupled with a greater enhancement in image contrast. Using an array processor, processing time was 0.2 sec per image for the Metz filter and 3 sec for the Wiener filter. It is concluded that two-dimensional digital image restoration with these techniques can produce a significant increase in SPECT image quality

  6. Evaluation of image reconstruction methods for {sup 123}I-MIBG-SPECT. A rank-order study

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid [Medical Radiation Physics, Dept. of Clinical Sciences Malmoe, Lund Univ., Skaane Univ. Hospital, Malmoe (Sweden)], e-mail: marcus.soderberg@med.lu.se; Valind, Sven; Thorsson, Ola; Garpered, Sabine [Dept. of Clinical Physiology, Skaane Univ. Hospital, Malmoe (Sweden); Prautzsch, Tilmann [Scivis wissenschaftlice Bildverarbeitung GmbH, Goettingen (Germany); Tischenko, Oleg [Research Unit Medical Radiation Physics and Diagnostics (AMSD), Helmholtz Zentrum Muenchen (Germany); German Research Center for Environmental Health, Neuherberg (Germany)

    2012-09-15

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on {sup 123}I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq {sup 123}I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D{sub 32} > ReSPECT > Flash 3D{sub 64} > OPED, and after 24 h: Flash 3D{sub 16} > ReSPECT > Flash 3D{sub 32} > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D{sub 32} (4 h) and Flash 3D{sub 16} (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of {sup 123}I-MIBG images.

  7. Can Dynamic Susceptibility Contrast Magnetic Resonance Imaging Replace Single-Photon Emission Computed Tomography in the Diagnosis of Patients with Alzheimer's Disease? A Pilot Study

    International Nuclear Information System (INIS)

    Cavallin, L.; Danielsson, R.; Oeksengard, A.R.; Wahlund, L.O.; Julin, P.; Frank, A.; Engman, E.L.; Svensson, L.; Kristoffersen Wiberg, M.

    2006-01-01

    Purpose: To compare single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer's disease (AD). Material and Methods: Twenty-four patients, eight with AD, 10 with MCI, and six controls were investigated with SPECT using 99m Tc-hexamethylpropyleneamine oxime (HMPAO) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with gadobutrol. Three observers performed a visual interpretation of the SPECT and MR images using a four-point visual scale. Results: SPECT was superior to DSC-MRI in differentiating normal from pathological. All three observers showed statistically significant results in discriminating between the control group, AD, and MCI by SPECT, with a P value of 0.0006, 0.04, and 0.01 for each observer. The statistical results were not significant for MR (P values 0.8, 0.1, and 0.2, respectively). Conclusion: DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer's disease. Several patient- and method-related improvements should be made before this method can be recommended for clinical practice

  8. In vivo SPECT reporter gene imaging of regulatory T cells.

    Directory of Open Access Journals (Sweden)

    Ehsan Sharif-Paghaleh

    Full Text Available Regulatory T cells (Tregs were identified several years ago and are key in controlling autoimmune diseases and limiting immune responses to foreign antigens, including alloantigens. In vivo imaging techniques including intravital microscopy as well as whole body imaging using bioluminescence probes have contributed to the understanding of in vivo Treg function, their mechanisms of action and target cells. Imaging of the human sodium/iodide symporter via Single Photon Emission Computed Tomography (SPECT has been used to image various cell types in vivo. It has several advantages over the aforementioned imaging techniques including high sensitivity, it allows non-invasive whole body studies of viable cell migration and localisation of cells over time and lastly it may offer the possibility to be translated to the clinic. This study addresses whether SPECT/CT imaging can be used to visualise the migratory pattern of Tregs in vivo. Treg lines derived from CD4(+CD25(+FoxP3(+ cells were retrovirally transduced with a construct encoding for the human Sodium Iodide Symporter (NIS and the fluorescent protein mCherry and stimulated with autologous DCs. NIS expressing self-specific Tregs were specifically radiolabelled in vitro with Technetium-99m pertechnetate ((99mTcO(4(- and exposure of these cells to radioactivity did not affect cell viability, phenotype or function. In addition adoptively transferred Treg-NIS cells were imaged in vivo in C57BL/6 (BL/6 mice by SPECT/CT using (99mTcO(4(-. After 24 hours NIS expressing Tregs were observed in the spleen and their localisation was further confirmed by organ biodistribution studies and flow cytometry analysis. The data presented here suggests that SPECT/CT imaging can be utilised in preclinical imaging studies of adoptively transferred Tregs without affecting Treg function and viability thereby allowing longitudinal studies within disease models.

  9. Interest of hybrid SPECT-CT imaging for diagnosis of infection

    International Nuclear Information System (INIS)

    Riviere, A.; Farid, K.; Guyot, M.; Jeandot, R.; Allard, M.; Fernandez, P.; Clermont, H. de; Dauchy, F.; Dupon, M.; Fernandez, P.

    2008-01-01

    Single-Photon Emission Computed Tomography-Computerized Tomography (SPECT-CT) is a new hybrid technique which offers new diagnostic capabilities in daily nuclear medicine practice. This technique not only allows to acquire merged anatomic and functional images in the same time, but also, it increases sensitivity and accuracy of SPECT thanks to attenuation and scattering corrections got from transmission data. Until now, SPECT-CT data have been mainly obtained in oncology and cardiology, but now, many authors use it in many scan studies and particularly for infectious diseases. In inflammatory bowel diseases, SPECT-CT seems to increase diagnostic performances and to modify management of many patients. In suspected vascular sepsis, SPECT-CT could increase sensitivity of white blood cell scintigraphy but also its specificity thanks to spatial resolution of CT. In osteo-articular sepsis, SPECT-CT has the advantage to distinguish osteomyelitis from soft tissue infection and to guide biopsies. Nevertheless, in the light of PET-CT works, SPECT-CT development will probably modify nuclear medicine practice and many studies have to be conducted to highlight consensual procedure guidelines. (authors)

  10. Assessment of smoking-induced impairment of pulmonary perfusion using three-dimensional SPECT images

    Energy Technology Data Exchange (ETDEWEB)

    Miyasaka, Takashi [Toho Univ., Tokyo (Japan). School of Medicine

    1997-09-01

    The effects of smoking on ventilation-perfusion lung scintigrams were investigated. The subjects comprised 40 healthy males (28 smokers and 12 nonsmokers) without a history of cardiopulmonary disease and with normal chest radiographs. After acquisition of planar images of ventilation lung scintigrams with 370 MBq of {sup 133}Xe gas, planar images and SPECT images of pulmonary perfusion flow were obtained using 185 MBq of {sup 99m}Tc-MAA. Planar imaging showed perfusion defects in only 5 smokers. In contrast, 16 subjects were found to have perfusion defects on SPECT images (p<0.05), indicating the usefulness of SPECT images in detecting minor vascular damage of the lung. Although perfusion defects were common in the smokers (p<0.05), their relationship to the BRINKMAN index was uncertain. The perfusion defects found in the smokers were nonsegmental and commonly involved the right upper lobe. Ventilation scans revealed only delayed washout of {sup 133}Xe in 4 smokers, suggesting that smoking-induced abnormal perfusion on SPECT appears earlier than impaired ventilation on scintigrams. (author)

  11. Radiolabelling of sperm cells with 99mTc-HMPAO. In vivo visualization of sperm cell migration in rabbits

    International Nuclear Information System (INIS)

    Bockisch, A.; Tennessee Univ., Knoxville, TN; Tennessee Univ., Knoxville, TN; Al-Hasani, S.; Ven, H.V.D.; Diedrich, K.; Krebs, D.; Posch, C.; Hotze, A.; Biersack, H.J.

    1989-01-01

    The present paper is the first descriptive radiolabeling of sperm cells in order to visualize their in vivo migration and imaging by scintigraphic technique, 99m Tc-HMPAO was used which combines favourable characteristics of both imaging modalities and radiation exposure. The radiolabeling yield was optimised for human sperm cells, and was increasing with the number of sperm cells, the amount of HMPAO, the 99m Tc-HMPAO concentration and the duration of the incubation. Incubation periods greater than 20 min, however, resulted only in a minor increase of labeling yield. A delay of more than 5 min between the labeling of the HMPAO with 99m Tc and initiation of the incubation of the sperm cells with the 99m Tc-HMPAO also decreased the maximum labeling yield. The radiolabeled cells were found to be stable and after 18 h > 93% of the activity was still bound to the sperm cells. After insemination of labeled sperm cells in ovulating rabbits the accumulation of the cells in the Fallopian tubes and their subsequent migration could be clearly visualized by scintigraphic techniques in vivo. (orig.) [de

  12. Improvement of image quality using interpolated projection data estimation method in SPECT

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Kojima, Akihiro; Asao, Kimie; Kamada, Shinya; Matsumoto, Masanori

    2009-01-01

    General data acquisition for single photon emission computed tomography (SPECT) is performed in 90 or 60 directions, with a coarse pitch of approximately 4-6 deg for a rotation of 360 deg or 180 deg, using a gamma camera. No data between adjacent projections will be sampled under these circumstances. The aim of the study was to develop a method to improve SPECT image quality by generating lacking projection data through interpolation of data obtained with a coarse pitch such as 6 deg. The projection data set at each individual degree in 360 directions was generated by a weighted average interpolation method from the projection data acquired with a coarse sampling angle (interpolated projection data estimation processing method, IPDE method). The IPDE method was applied to the numerical digital phantom data, actual phantom data and clinical brain data with Tc-99m ethyle cysteinate dimer (ECD). All SPECT images were reconstructed by the filtered back-projection method and compared with the original SPECT images. The results confirmed that streak artifacts decreased by apparently increasing a sampling number in SPECT after interpolation and also improved signal-to-noise (S/N) ratio of the root mean square uncertainty value. Furthermore, the normalized mean square error values, compared with standard images, had similar ones after interpolation. Moreover, the contrast and concentration ratios increased their effects after interpolation. These results indicate that effective improvement of image quality can be expected with interpolation. Thus, image quality and the ability to depict images can be improved while maintaining the present acquisition time and image quality. In addition, this can be achieved more effectively than at present even if the acquisition time is reduced. (author)

  13. Pixel based statistical analysis of differences between lung SPECT images: methodological aspects

    International Nuclear Information System (INIS)

    Bendada, S.; Rocchisani, J.L.M.; Moretti, J.L.

    2002-01-01

    The statistical parametric mapping method is applied in Neurology for activation studies. We had adapted this powerful method on Lungs SPECT to help for the diagnosis and the follow-up of pulmonary embolism and other lung diseases. The SPECT slices of pairs of examination were normalized thanks to the total acquired counts, reconstruction background subtracted, smoothed and realigned. A parametric image of statistical differences was finally computed. We had thus obtained a 3D image showing regions of improved or altered region under treatment. A tuning of the various parameters could lead to more accurate image. This new approach of lung SPECT processing appears to be a promising useful tool for the physician. (author)

  14. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-15

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with {sup 99m}Tc-MDP, DMSA, and {sup 18}F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, {sup 99m}Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined {sup 99}mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and {sup 18}F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug.

  15. Establishment study of the in vivo imaging analysis with small animal imaging modalities (micro-PET and micro-SPECT/CT) for bio-drug development

    International Nuclear Information System (INIS)

    Jang, Beomsu; Park, Sanghyeon; Park, Jeonghoon; Jo, Sungkee; Jung, Uhee; Kim, Seolwha; Lee, Yunjong; Choi, Daeseong

    2011-01-01

    In this study, we established the image acquisition and analysis procedures of micro-PET, SPECT/CT using the experimental animal (mouse) for the development of imaging assessment method for the bio-drug. We examined the micro-SPECT/CT, PET imaging study using the Siemens Inveon micro-multimodality system (SPECT/CT) and micro-PET with 99m Tc-MDP, DMSA, and 18 F-FDG. SPECT imaging studies using 3 types of pinhole collimators. 5-MWB collimator was used for SPECT image study. To study whole-body distribution, 99m Tc-MDP SPECT image study was performed. We obtained the fine distribution image. And the CT images was obtained to provide the anatomical information. And then these two types images are fused. To study specific organ uptake, we examined 99 mTc-DMSA SPECT/CT imaging study. We also performed the PET image study using U87MG tumor bearing mice and 18 F-FDG. The overnight fasting, warming and anesthesia with 2% isoflurane pretreatment enhance the tumor image through reducing the background uptake including brown fat, harderian gland and skeletal muscles. Also we got the governmental approval for use of x-ray generator for CT and radioisotopes as sealed and open source. We prepared the draft of process procedure for the experimental animal imaging facility. These research results can be utilized as a basic image study protocols and data for the image assessment of drugs including biological drug

  16. Effects of cross talk on dual energy SPECT imaging between 123I-BMIPP and 201Tl

    International Nuclear Information System (INIS)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.)

  17. Diagnostic evaluation of brain SPECT imaging in diseases of nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Yongsheng, Jiang; Chengmo, Zhu; Jixian, Zhang; Weijia, Tian [Shanghai Second Medical Univ. (China). Ruijing Hospital

    1992-11-01

    The dynamic distributions of home made ECD and the Amersham brain SPECT imaging agent 'Ceretec' in normal person as well as their diagnostic use in diseases of nervous system were investigated. Semi-quantitative analysis combined with direct observation was more accurate for the diagnosis. Aside from cerebrovascular diseases, SPECT brain imaging has its unique value for the diagnosis of transient ischemic attack, Alzheimer disease, multiple ischemic dementia and epilepsy etc.

  18. SPECT/CT image fusion with 99mTc-HYNIC-TOC in the oncological diagnostic

    International Nuclear Information System (INIS)

    Haeusler, F.

    2006-07-01

    Neuroendocrine tumours displaying somatostatin receptors have been successfully visualized with somatostatin receptor imaging. The aim of this retrospective study was to evaluate the value of anatomical-functional image fusion. Image fusion means the combined transmission and emission tomography (computed tomography (CT)) and single-photon emission computed tomography (SPECT) ) and was analyzed in comparison with SPECT and CT alone. Fifty-three patients (30 men and 23 women; mean age 55,9 years; range: 20-82 years) with suspected or known endocrine tumours were studied. The patients were referred to image fusion because of staging of newly diagnosed tumours (14) or biochemically/clinically suspected neuroendocrine tumour (20) or follow-up studies after therapy (19). The patients were studied with SPECT at 2 and 4 hours after injection of 400 MBq of 99mTc-EDDA-HYNIC-Tyr3-octreotide using a dual-detector scintillation camera. The CT was performed on one of the following two days. For both investigations the patients were fixed in an individualized vacuum mattress to guarantee exactly the same position. SPECT and SPECT/CT showed an equivalent scan result in 35 patients (66 %), discrepancies were found in 18 cases (34 %). After image fusion the scan result was true-positive in 27 patients ( 50.9 %) and true-negative in 25 patients (47.2 %). One patient with multiple small liver metastases escaped SPECT as well as image fusion and was so false-negative. The frequency of equivocal and probable lesion characterization was reduced by 11.6% (12 to 0) with PET/CT in comparison with PET or CT alone. The frequency of definite lesion characterization was increased by 11.6% (91 to 103). SPECT/CT affected the clinical management in 21 patients (40 %). The results of this study indicate that SPECT/CT is a valuable tool for the assessment of neuroendocrine tumours. SPECT/CT is better than SPECT or CT alone and it allows a more precise staging and determination of prognosis and

  19. Imaging the neurobiological substrate of atypical depression by SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Pagani, Marco [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Karolinska University Hospital, Department of Nuclear Medicine, Stockholm (Sweden); Salmaso, Dario [Institute of Cognitive Sciences and Technologies, CNR, Rome (Italy); Nardo, Davide [University of Rome La Sapienza, Department of Psychology, Rome (Italy); Jonsson, Cathrine; Larsson, Stig A. [Karolinska University Hospital, Department of Nuclear Medicine, Stockholm (Sweden); Jacobsson, Hans [Karolinska University Hospital, Department of Radiology, Stockholm (Sweden); Gardner, Ann [Karolinska University Hospital Huddinge, Karolinska Institutet, Department of Clinical Neuroscience, Section of Psychiatry, Stockholm (Sweden)

    2007-01-15

    Neurobiological abnormalities underlying atypical depression have previously been suggested. The purpose of this study was to explore differences at functional brain imaging between depressed patients with and without atypical features and healthy controls. Twenty-three out-patients with chronic depressive disorder recruited from a service for patients with audiological symptoms were investigated. Eleven fulfilled the DSM-IV criteria for atypical depression (mood reactivity and at least two of the following: weight gain, hypersomnia, leaden paralysis and interpersonal rejection sensitivity). Twenty-three healthy subjects served as controls. Voxel-based analysis was applied to explore differences in {sup 99m}Tc-HMPAO uptake between groups. Patients in the atypical group had a higher prevalence of bilateral hearing impairment and higher depression and somatic distress ratings at the time of SPECT. Significantly higher tracer uptake was found bilaterally in the atypical group as compared with the non-atypicals in the sensorimotor (Brodmann areas, BA1-3) and premotor cortex in the superior frontal gyri (BA6), in the middle frontal cortex (BA8), in the parietal associative cortex (BA5, BA7) and in the inferior parietal lobule (BA40). Significantly lower tracer distribution was found in the right hemisphere in the non-atypicals compared with the controls in BA6, BA8, BA44, BA45 and BA46 in the frontal cortex, in the orbito-frontal cortex (BA11, BA47), in the postcentral parietal cortex (BA2) and in the multimodal association parietal cortex (BA40). The differences found between atypical and non-atypical depressed patients suggest different neurobiological substrates in these patient groups. The putative links with the clinical features of atypical depression are discussed. These findings encourage the use of functional neuroimaging in psychiatric disorders. (orig.)

  20. Imaging the neurobiological substrate of atypical depression by SPECT

    International Nuclear Information System (INIS)

    Pagani, Marco; Salmaso, Dario; Nardo, Davide; Jonsson, Cathrine; Larsson, Stig A.; Jacobsson, Hans; Gardner, Ann

    2007-01-01

    Neurobiological abnormalities underlying atypical depression have previously been suggested. The purpose of this study was to explore differences at functional brain imaging between depressed patients with and without atypical features and healthy controls. Twenty-three out-patients with chronic depressive disorder recruited from a service for patients with audiological symptoms were investigated. Eleven fulfilled the DSM-IV criteria for atypical depression (mood reactivity and at least two of the following: weight gain, hypersomnia, leaden paralysis and interpersonal rejection sensitivity). Twenty-three healthy subjects served as controls. Voxel-based analysis was applied to explore differences in 99m Tc-HMPAO uptake between groups. Patients in the atypical group had a higher prevalence of bilateral hearing impairment and higher depression and somatic distress ratings at the time of SPECT. Significantly higher tracer uptake was found bilaterally in the atypical group as compared with the non-atypicals in the sensorimotor (Brodmann areas, BA1-3) and premotor cortex in the superior frontal gyri (BA6), in the middle frontal cortex (BA8), in the parietal associative cortex (BA5, BA7) and in the inferior parietal lobule (BA40). Significantly lower tracer distribution was found in the right hemisphere in the non-atypicals compared with the controls in BA6, BA8, BA44, BA45 and BA46 in the frontal cortex, in the orbito-frontal cortex (BA11, BA47), in the postcentral parietal cortex (BA2) and in the multimodal association parietal cortex (BA40). The differences found between atypical and non-atypical depressed patients suggest different neurobiological substrates in these patient groups. The putative links with the clinical features of atypical depression are discussed. These findings encourage the use of functional neuroimaging in psychiatric disorders. (orig.)

  1. Can Dynamic Susceptibility Contrast Magnetic Resonance Imaging Replace Single-Photon Emission Computed Tomography in the Diagnosis of Patients with Alzheimer's Disease? A Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Cavallin, L.; Danielsson, R.; Oeksengard, A.R.; Wahlund, L.O.; Julin, P.; Frank, A.; Engman, E.L.; Svensson, L.; Kristoffersen Wiberg, M. [Karolinska Univ. Hospital, Stockholm (Sweden). Div. of Radiology

    2006-11-15

    Purpose: To compare single-photon emission computed tomography (SPECT) and magnetic resonance imaging (MRI) in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer's disease (AD). Material and Methods: Twenty-four patients, eight with AD, 10 with MCI, and six controls were investigated with SPECT using {sup 99m}Tc-hexamethylpropyleneamine oxime (HMPAO) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with gadobutrol. Three observers performed a visual interpretation of the SPECT and MR images using a four-point visual scale. Results: SPECT was superior to DSC-MRI in differentiating normal from pathological. All three observers showed statistically significant results in discriminating between the control group, AD, and MCI by SPECT, with a P value of 0.0006, 0.04, and 0.01 for each observer. The statistical results were not significant for MR (P values 0.8, 0.1, and 0.2, respectively). Conclusion: DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer's disease. Several patient- and method-related improvements should be made before this method can be recommended for clinical practice.

  2. Comparison of planar images and SPECT with bayesean preprocessing for the demonstration of facial anatomy and craniomandibular disorders

    International Nuclear Information System (INIS)

    Kircos, L.T.; Ortendahl, D.A.; Hattner, R.S.; Faulkner, D.; Taylor, R.L.

    1984-01-01

    Craniomandiublar disorders involving the facial anatomy may be difficult to demonstrate in planar images. Although bone scanning is generally more sensitive than radiography, facial bone anatomy is complex and focal areas of increased or decreased radiotracer may become obscured by overlapping structures in planar images. Thus SPECT appears ideally suited to examination of the facial skeleton. A series of patients with craniomandibular disorders of unknown origin were imaged using 20 mCi Tc-99m MDP. Planar and SPECT (Siemens 7500 ZLC Orbiter) images were obtained four hours after injection. The SPECT images were reconstructed with a filtered back-projection algorithm. In order to improve image contrast and resolution in SPECT images, the rotation views were pre-processed with a Bayesean deblurring algorithm which has previously been show to offer improved contrast and resolution in planar images. SPECT images using the pre-processed rotation views were obtained and compared to the SPECT images without pre-processing and the planar images. TMJ arthropathy involving either the glenoid fossa or the mandibular condyle, orthopedic changes involving the mandible or maxilla, localized dental pathosis, as well as changes in structures peripheral to the facial skeleton were identified. Bayesean pre-processed SPECT depicted the facial skeleton more clearly as well as providing a more obvious demonstration of the bony changes associated with craniomandibular disorders than either planar images or SPECT without pre-processing

  3. [Application of GVF snake model in segmentation of whole body bone SPECT image].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2008-02-01

    Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.

  4. Stereotactic imaging for radiotherapy: accuracy of CT, MRI, PET and SPECT

    International Nuclear Information System (INIS)

    Karger, Christian P; Hipp, Peter; Henze, Marcus; Echner, Gernot; Hoess, Angelika; Schad, Lothar; Hartmann, Guenther H

    2003-01-01

    CT, MRI, PET and SPECT provide complementary information for treatment planning in stereotactic radiotherapy. Stereotactic correlation of these images requires commissioning tests to confirm the localization accuracy of each modality. A phantom was developed to measure the accuracy of stereotactic localization for CT, MRI, PET and SPECT in the head and neck region. To this end, the stereotactically measured coordinates of structures within the phantom were compared with their mechanically defined coordinates. For MRI, PET and SPECT, measurements were performed using two different devices. For MRI, T1- and T2-weighted imaging sequences were applied. For each measurement, the mean radial deviation in space between the stereotactically measured and mechanically defined position of target points was determined. For CT, the mean radial deviation was 0.4 ± 0.2 mm. For MRI, the mean deviations ranged between 0.7 ± 0.2 mm and 1.4 ± 0.5 mm, depending on the MRI device and the imaging sequence. For PET, mean deviations of 1.1 ± 0.5 mm and 2.4 ± 0.3 mm were obtained. The mean deviations for SPECT were 1.6 ± 0.5 mm and 2.0 ± 0.6 mm. The phantom is well suited to determine the accuracy of stereotactic localization with CT, MRI, PET and SPECT in the head and neck region. The obtained accuracy is well below the physical resolution for CT, PET and SPECT, and of comparable magnitude for MRI. Since the localization accuracy may be device dependent, results obtained at one device cannot be generalized to others

  5. High-resolution brain SPECT imaging by combination of parallel and tilted detector heads.

    Science.gov (United States)

    Suzuki, Atsuro; Takeuchi, Wataru; Ishitsu, Takafumi; Morimoto, Yuichi; Kobashi, Keiji; Ueno, Yuichiro

    2015-10-01

    To improve the spatial resolution of brain single-photon emission computed tomography (SPECT), we propose a new brain SPECT system in which the detector heads are tilted towards the rotation axis so that they are closer to the brain. In addition, parallel detector heads are used to obtain the complete projection data set. We evaluated this parallel and tilted detector head system (PT-SPECT) in simulations. In the simulation study, the tilt angle of the detector heads relative to the axis was 45°. The distance from the collimator surface of the parallel detector heads to the axis was 130 mm. The distance from the collimator surface of the tilted detector heads to the origin on the axis was 110 mm. A CdTe semiconductor panel with a 1.4 mm detector pitch and a parallel-hole collimator were employed in both types of detector head. A line source phantom, cold-rod brain-shaped phantom, and cerebral blood flow phantom were evaluated. The projection data were generated by forward-projection of the phantom images using physics models, and Poisson noise at clinical levels was applied to the projection data. The ordered-subsets expectation maximization algorithm with physics models was used. We also evaluated conventional SPECT using four parallel detector heads for the sake of comparison. The evaluation of the line source phantom showed that the transaxial FWHM in the central slice for conventional SPECT ranged from 6.1 to 8.5 mm, while that for PT-SPECT ranged from 5.3 to 6.9 mm. The cold-rod brain-shaped phantom image showed that conventional SPECT could visualize up to 8-mm-diameter rods. By contrast, PT-SPECT could visualize up to 6-mm-diameter rods in upper slices of a cerebrum. The cerebral blood flow phantom image showed that the PT-SPECT system provided higher resolution at the thalamus and caudate nucleus as well as at the longitudinal fissure of the cerebrum compared with conventional SPECT. PT-SPECT provides improved image resolution at not only upper but also at

  6. Application of SPECT/CT imaging in the diagnosis of benign diseases

    International Nuclear Information System (INIS)

    Garcheva, M.; Demirev, A.

    2014-01-01

    The application of recently introduced hybrid nuclear medicine methods gains importance in a variety of clinical fields, mainly because of the unique combination between functional and anatomical data provided by those methods and their capability for a precise localization of pathological processes. Single photon emission computed tomography, combined with computed tomography (SPECT/CT) is one of those methods. Its role in nuclear cardiology is important, because it provides quick attenuation correction and calculates the calcium score. In nuclear endocrinology SPECT/CT participates in thyroid and parathyroid examinations, especially in cases, where there is a need for localization of ectopic parathyroid or thyroid tissue. In nuclear pulmonology, one of the best ways to attribute certain changes seen on the SPECT, to the zone of interest on the CT, is to study the fused images obtained from the SPECT/ CT scanner. In cases of suspected infection and inflammation, fused images are indispensable for accurate localization of the involved tissue (structure) and for discrimination between normal/abnormal uptake. Careful reading of the CT component (even low-dose) is related (in 10% of cases) to clinically important incidental findings: effusions, tumors, metastases or lymph node pathology. SPECT/CT increases the specificity of the examinations and improves significantly the localization of pathological processes. It provides additional information, shortens the diagnostic algorithm and influences the extent of surgical procedures. In many hybrid examinations the preferred CT component is a low-dose one, without considerable radiation exposure. The opportunity to combine nuclear medicine techniques and contrast CT images, aiming at better diagnosis needs further development. SPECT/CT provides important additional information and more accurate diagnostics in patients with benign diseases. (authors) Key words: SPECT/CT. BENIGN DISEASES

  7. Myocardial Infarction Area Quantification using High-Resolution SPECT Images in Rats

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Luciano Fonseca Lemos de [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Mejia, Jorge [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Carvalho, Eduardo Elias Vieira de; Lataro, Renata Maria; Frassetto, Sarita Nasbine [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Fazan, Rubens Jr.; Salgado, Hélio Cesar [Departamento de Fisiologia, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil); Galvis-Alonso, Orfa Yineth [Faculdade de Medicina de São José do Rio Preto, São José do Rio Preto, SP (Brazil); Simões, Marcus Vinícius, E-mail: msimoes@fmrp.usp.br [Divisão de Cardiologia, Departamento de Clínica Médica, Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, SP (Brazil)

    2013-07-15

    Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. To determine the accuracy of this system for quantification of myocardial infarct area in rats. Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq of 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.

  8. SPECT/CT imaging in bone scintigraphy of a case of clavicular osteoma

    International Nuclear Information System (INIS)

    Yamamoto, Yuka; Nishiyama, Yoshihiro

    2014-01-01

    Osteoma is a benign bone-forming tumor that usually arises in the craniofacial bones and rarely in the long bones. Clavicular involvement is extremely rare. We report a 51-year-old woman with osteoma of the left clavicle. Radiograph of the left shoulder showed a well-defined lobulated blastic mass in the proximal and mid-portion of the left clavicle. Bone scintigraphy was performed 4 hours after an intravenous injection of Tc-99m hydroxymethylene diphosphonate (HMDP). Whole-body image showed a focus of intensely increased uptake in the clavicle. Single photon emission computed tomography / computed tomography (SPECT/CT) images were also acquired and clearly showed intense uptake at the tumor site. Integrated SPECT/CT imaging supplies both functional and anatomic information about bone the SPECT imaging improves sensitivity compared with planar imaging, the CT imaging provides precise localization of the abnormal uptake, and information on the shape and structure of the abnormalities improves the specificity of the diagnosis

  9. Clinical usefulness of scatter and attenuation correction for brain single photon emission computed tomography (SPECT) in pediatrics

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Itaru; Doi, Kenji; Komori, Tsuyoshi; Hou, Nobuyoshi; Tabuchi, Koujirou; Matsui, Ritsuo; Sueyoshi, Kouzou; Utsunomiya, Keita; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1998-01-01

    This investigation was undertaken to study clinical usefulness of scatter and attenuation correction (SAC) of brain SPECT in infants to compare the standard reconstruction (STD). The brain SPECT was performed in 31 patients with 19 epilepsy, 5 cerebro-vascular disease, 2 brain tumor, 3 meningitis, 1 hydrocephalus and psychosis (mean age 5.0{+-}4.9 years old). Many patients was necessary to be injected sedatives for restraining body motion after Technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) was injected at the convulsion or rest. Brain SPECT data were acquired with triple detector gamma camera (GCA-9300 Toshiba Japan). These data were reconstructed by filtered backprojection after the raw data were corrected by triple energy windows method of scatter correction and Chang filtered method of attenuation correction. The same data was reconstructed by filtered backprojection without these corrections. Both SAC and STD SPECT images were analyzed by the visual interpretation. The uptake ratio of cerebral basal nuclei was calculated by the counts of the thalamus or lenticular nuclei divided by the cortex. All images of SAC method were excellent than that of STD method. The thalamic uptake ratio in SAC method was higher than that of STD method (1.22{+-}0.09>0.87{+-}0.22 p<0.01). The lenticular nuclear uptake ratio in SAC method was higher than that of STD method (1.26{+-}0.15>1.02{+-}0.16 p<0.01). Transmission scan is the most suitable method of absorption correction. But the transmission scan is not adequate for examination of children, because this scan needs a lot of time and the infants are exposed by the line source radioisotope. It was concluded that these scatter and absorption corrections were most suitable method for brain SPECT in pediatrics. (author)

  10. Technetium-99m-HMPAO SPECT in patients with hemiconvulsions followed by Todd`s paralysis

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, M.; Sejima, Hitoshi; Ozasa, Hiroshi; Yamaguchi, Seiji [Department of Pediatrics, Shimane Medical University, 89-1 Enya-cho, Izumo, Shimane 693 (Japan)

    1998-02-01

    We performed technetium-99m-hexamethylpropylene- amineoxime (Tc-HMPAO) single photon emission computed tomography in two patients with prolonged hemiconvulsions followed by transient hemiparesis (Todd`s paralysis). In both cases, a prolonged post-ictal cerebral hyperperfusion state of approximately 24 h was observed, even after the neurological deficits had resolved. The cerebral hyperperfusion in both cases was of much longer duration than that in previously reported cases of single and uncomplicated focal seizures. The prolonged cerebral hyperperfusion might have been due to impairment of the cerebrovascular autoregulation in seizures followed by Todd`s paralysis. (orig.) With 2 figs., 9 refs.

  11. Intravenous dipyridamole thallium-201 SPECT imaging in patients with left bundle branch block

    International Nuclear Information System (INIS)

    Rockett, J.F.; Wood, W.C.; Moinuddin, M.; Loveless, V.; Parrish, B.

    1990-01-01

    Tl-201 exercise imaging in patients with left bundle branch block (LBBB) has proven to be indeterminate for significant left anterior descending (LAD) coronary artery stenosis because of the presence of immediate septal perfusion defects with redistribution on delayed images in almost all cases. Tl-201 redistribution occurs regardless of the presence or absence of LAD stenosis. Nineteen patients having LBBB were evaluated with dipyridamole Tl-201 SPECT. Fourteen of these subjects had normal dipyridamole Tl-201 SPECT imaging. Three patients had normal coronary angiograms. None of the remaining 11 patients with normal dipyridamole Tl-201 SPECT images was found to have clinical coronary artery disease in a 5-11 month follow-up period. Five patients had abnormal septal perfusion. Four underwent coronary angiography. One had a significant LAD stenosis. The single patient with septal redistribution who refused to undergo coronary angiography died shortly thereafter of clinical coronary artery disease. This preliminary work suggests that dipyridamole Tl-201 SPECT may be more useful for excluding LAD stenosis in patients with LBBB than Tl-201 exercise imaging

  12. Performance characterization of the Inveon preclinical small-animal PET/SPECT/CT system for multimodality imaging

    International Nuclear Information System (INIS)

    Magota, Keiichi; Kubo, Naoki; Kuge, Yuji; Nishijima, Ken-ichi; Zhao, Songji; Tamaki, Nagara

    2011-01-01

    We investigated the performance of the Inveon small-animal PET/SPECT/CT system and compared the imaging capabilities of the SPECT and PET components. For SPECT, the energy resolution, tomographic spatial resolution and system sensitivity were evaluated with a 99m Tc solution using a single pinhole collimator. For PET, the spatial resolution, absolute sensitivity, scatter fraction and peak noise equivalent count were evaluated. Phantoms and a normal rat were scanned to compare the imaging capabilities of SPECT and PET. The SPECT spatial resolution was 0.84 mm full-width at half-maximum (FWHM) at a radius of rotation of 25 mm using a 0.5-mm pinhole aperture collimator, while the PET spatial resolution was 1.63 mm FWHM at the centre. The SPECT system sensitivity at a radius of rotation of 25 mm was 35.3 cps/MBq (4 x 10 -3 %) using the 0.5-mm pinhole aperture, while the PET absolute sensitivity was 3.2% for 350-650 keV and 3.432 ns. Accordingly, the volume sensitivity of PET was three orders of magnitude higher than that of SPECT. This integrated PET/SPECT/CT system showed high performance with excellent spatial resolution for SPECT and sensitivity for PET. Based on the tracer availability and system performance, SPECT and PET have complementary roles in multimodality small-animal imaging. (orig.)

  13. Cerebral perfusion changes in schizophrenia patients evaluated with Tc-99 HMPAO

    International Nuclear Information System (INIS)

    Sehweil, A.; El-Hilu, S.; Jahan, S.; Higazi, E.; Salhat, M.; Al-Mohannadi, S.; Abdel-Dayem, H.M.

    1989-01-01

    Tc-99m HMPAO has been used to image cerebral perfusion changes in 20 chronic schizophrenia patients (19 men and 1 woman), with an average age of 29 years (range, 22-48 years). All were receiving neuroleptic drugs. Twelve had received electroconvulsive therapy. All patients had abnormal studies (except one, which was normal) and poor response to treatment. Ventricular dilation and cerebral atrophy were seen in 11 patients. Seventy-seven focal lesions were detected. Forty-two lesions showed increased HMPAO retention: 26 in the basal ganglia in 14 patients (12, bilateral, two unilateral), 10 along the sylvian fissure in the parietotemporal region, three in the frontal region, and one in each of the temporal, parietal, and occipital regions. Thirty-five focal lesions showed decreased perfusion: 10 parietal, eight frontal, seven temporal, six cerebellar, and four occipital. This study demonstrates the potential value of Tc-99m HMPAO in the study of schizophrenia and other psychiatric disorders

  14. Diagnosis of Alzheimer's disease using brain perfusion SPECT and MR imaging: which modality achieves better diagnostic accuracy?

    International Nuclear Information System (INIS)

    Kubota, Takao; Ushijima, Yo; Yamada, Kei; Okuyama, Chio; Kizu, Osamu; Nishimura, Tsunehiko

    2005-01-01

    The purpose of this study was to compare the accuracy of MR imaging and brain perfusion single-photon emission tomography (SPECT) in diagnosing Alzheimer's disease (AD). The transaxial section display of brain perfusion SPECT, three-dimensional stereotactic surface projection (3D-SSP) SPECT image sets, thin-section MR imaging of the hippocampus and perfusion MR imaging were evaluated in 66 subjects comprising 35 AD patients and 31 subjects without AD. SPECT and MR imaging were visually interpreted by two experts and two novices, and the diagnostic ability of each modality was evaluated by receiver operating characteristic (ROC) analysis. In the experts' interpretations, there was no significant difference in the area under the ROC curve (A z ) between 3D-SSP and thin-section MR imaging, whereas the A z of transaxial SPECT display was significantly lower than that of 3D-SSP (3D-SSP: 0.97, thin-section MR imaging: 0.96, transaxial SPECT: 0.91), and the A z of perfusion MR imaging was lowest (0.63). The sensitivity and specificity of each modality were, respectively, 80.0% and 96.8% for 3D-SSP, 77.1% and 96.8% for thin-section MR imaging, 60.0% and 93.5% for transaxial SPECT display and 34.3% and 100% for perfusion MR imaging. In the novices' interpretations, the A z , sensitivity and specificity of 3D-SSP were superior to those of thin-section MR imaging. Thin-section hippocampal MR imaging and 3D-SSP image sets had potentially equivalent value for the diagnosis of AD, and they were superior to transaxial SPECT display and perfusion MR imaging. For avoidance of the effect of interpreters' experience on image evaluation, 3D-SSP appears to be optimal. (orig.)

  15. Stabilization of Tc-99m D,L-HMPAO preparations as a leucocyte labelling agent

    International Nuclear Information System (INIS)

    Kao, C.H.; Huang, W.T.; Tsai, C.S.

    1998-01-01

    An attempt was made to use stabilized Tc-99m D,L-HMPAO (S-HMPAO) to label leucocytes. The radiochemical purity of Tc-99m D,L-HMPAO, labelling efficiency of leucocytes, cell viability of labelled leucocytes, and stability of S-HMPAO labelled leucocytes were calculated. In comparison with commercial Tc-99m D,L-HMPAO (C-HMPAO) without stabilization, immediately, at 0.5, 1, 2, 4, and 6 h after HMPAO preparation, the radiochemical purity of S-HMPAO and the labelling efficiencies of S-HMPAO labelled leucocytes were higher. S-HMPAO is more stable than C-HMPAO and can provide higher leucocyte labelling efficiency. S-HMPAO, therefore, has the potential to replace C-HMPAO as a leucocyte-labelling agent

  16. Measurement of heterogeneous distribution on technegas SPECT images by three-dimensional fractal analysis

    International Nuclear Information System (INIS)

    Nagao, Michinobu; Murase, Kenya

    2002-01-01

    This review article describes a method for quantifying heterogeneous distribution on Technegas ( 99m Tc-carbon particle radioaerosol) SPECT images by three-dimensional fractal analysis (3D-FA). Technegas SPECT was performed to quantify the severity of pulmonary emphysema. We delineated the SPECT images by using five cut-offs (15, 20, 25, 30 and 35% of the maximal voxel radioactivity), and measured the total number of voxels in the areas surrounded by the contours obtained with each cut-off level. We calculated fractal dimensions from the relationship between the total number of voxels and the cut-off levels transformed into natural logarithms. The fractal dimension derived from 3D-FA is the relative and objective measurement, which can assess the heterogeneous distribution on Technegas SPECT images. The fractal dimension strongly correlate pulmonary function in patients with emphysema and well documented the overall and regional severity of emphysema. (author)

  17. Episodic aphasia associated with tumor active multiple sclerosis: a correlative SPECT study utilising image fusion

    International Nuclear Information System (INIS)

    Roff, G.; Campbell, A.; Lawn, N.; Henderson, A.; McCarthy, M.; Lenzo, N.

    2003-01-01

    Full text: Cerebral perfusion imaging is a common technique to assess cerebral perfusion and metabolism. It can complement anatomical imaging in assessing a number of neurological conditions. At times it can better define the clinical manifestations of a disease process than anatomical imaging alone. We present a clinical case whereby cerebral SPECT imaging helped define the physiological reason for intermittent aphasia in a patient with tumor active multiple sclerotic white matter plaques. Cerebral SPECT studies were performed during a period of aphasia and when the patient had recovered. We utilised subtraction analyses and image fusion techniques to better define the changes seen on SPECT. We discuss the neuroanatomical relationship of aphasia and the automatic fusion technique that allows accurate co-registration of the MRI and SPECT data. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  18. Different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains: analysis by statistical parametric mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I.Y. [Dept. of Nuclear Medicine, Inha University College of Medicine, Incheon (Korea); Lee, J.S.; Lee, D.S. [Dept. of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea); Rha, J.H.; Lee, I.K.; Ha, C.K. [Dept. of Neurology, Inha University College of Medicine, Incheon (Korea)

    2001-02-01

    The purpose of this study was to investigate the differences between technetium-99m ethyl cysteinate dimer ({sup 99m}Tc-ECD) and technetium-99m hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) uptake in the same brains by means of statistical parametric mapping (SPM) analysis. We examined 20 patients (9 male, 11 female, mean age 62{+-}12 years) using {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO single-photon emission tomography (SPET) and magnetic resonance imaging (MRI) of the brain less than 7 days after onset of stroke. MRI showed no cortical infarctions. Infarctions in the pons (6 patients) and medulla (1), ischaemic periventricular white matter lesions (13) and lacunar infarction (7) were found on MRI. Split-dose and sequential SPET techniques were used for {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO brain SPET, without repositioning of the patient. All of the SPET images were spatially transformed to standard space, smoothed and globally normalized. The differences between the {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET images were statistically analysed using statistical parametric mapping (SPM) 96 software. The difference between two groups was considered significant at a threshold of uncorrected P values less than 0.01. Visual analysis showed no hypoperfused areas on either {sup 99m}Tc-ECD or {sup 99m}Tc-HMPAO SPET images. SPM analysis revealed significantly different uptake of {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO in the same brains. On the {sup 99m}Tc-ECD SPET images, relatively higher uptake was observed in the frontal, parietal and occipital lobes, in the left superior temporal lobe and in the superior region of the cerebellum. On the {sup 99m}Tc-HMPAO SPET images, relatively higher uptake was observed in the medial temporal lobes, thalami, periventricular white matter and brain stem. These differences in uptake of the two tracers in the same brains on SPM analysis suggest that interpretation of cerebral perfusion is possible using SPET with {sup 99m}Tc-ECD and

  19. A hardware investigation of robotic SPECT for functional and molecular imaging onboard radiation therapy systems

    International Nuclear Information System (INIS)

    Yan, Susu; Tough, MengHeng; Bowsher, James; Yin, Fang-Fang; Cheng, Lin

    2014-01-01

    Purpose: To construct a robotic SPECT system and to demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch, as a step toward onboard functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150 L110 robot). An imaging study was performed with a phantom (PET CT Phantom TM ), which includes five spheres of 10, 13, 17, 22, and 28 mm diameters. The phantom was placed on a flat-top couch. SPECT projections were acquired either with a parallel-hole collimator or a single-pinhole collimator, both without background in the phantom and with background at 1/10th the sphere activity concentration. The imaging trajectories of parallel-hole and pinhole collimated detectors spanned 180° and 228°, respectively. The pinhole detector viewed an off-centered spherical common volume which encompassed the 28 and 22 mm spheres. The common volume for parallel-hole system was centered at the phantom which encompassed all five spheres in the phantom. The maneuverability of the robotic system was tested by navigating the detector to trace the phantom and flat-top table while avoiding collision and maintaining the closest possible proximity to the common volume. The robot base and tool coordinates were used for image reconstruction. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector radius of rotation. Without background, all five spheres were visible in the reconstructed parallel-hole image, while four spheres, all except the smallest one, were visible in the reconstructed pinhole image. With background, three spheres of 17, 22, and 28 mm diameters were readily observed with the parallel-hole imaging, and the targeted spheres (22 and 28 mm diameters) were readily observed in the pinhole

  20. SPECT and PET Serve as Molecular Imaging Techniques and in Vivo Biomarkers for Brain Metastases

    Science.gov (United States)

    Palumbo, Barbara; Buresta, Tommaso; Nuvoli, Susanna; Spanu, Angela; Schillaci, Orazio; Fravolini, Mario Luca; Palumbo, Isabella

    2014-01-01

    Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET) represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI) is discussed. PMID:24897023

  1. Examination of attenuation correction method for cerebral blood Flow SPECT Using MR imaging

    International Nuclear Information System (INIS)

    Mizuno, Takashi; Takahashi, Masaaki

    2009-01-01

    Authors developed a software for attenuation correction using MR imaging (MRAC) (Toshiba Med. System Engineer.) based on the idea that precision of AC could be improved by the head contour in MRI T2-weighted images (T2WI) obtained before 123 I-iofetamine (IMP) single photon emission computed tomography (SPECT) for cerebral blood flow (CBF) measurement. In the present study, this MRAC was retrospectively evaluated by comparison with the previous standard AC methods derived from transmission CT (TCT) and X-CT which overcoming the problem of sinogram threshold Chang method but still having cost and patient exposure issues. MRAC was essentially performed in the Toshiba GMS5500/PI processor where 3D registration was conducted with images of SPECT and MRI of the same patient. The gamma camera for 123 I-IMP SPECT and 99m TcO 4 - TCT was Toshiba 3-detector GCA9300A equipped with the above processor for MRAC and with low energy high resolution (LEHR) fan beam collimator. Machines for MRI and CT were Siemens-Asahi Meditech. MAGNETOM Symphony 1.5T and SOMATOM plus4, respectively. MRAC was examined in 8 patients with images of T1WI, TCT and SPECT, and in 18 of T2WI, CT and SPECT. Evaluation was made by comparison of attenuation coefficients (μ) by the 4 methods. As a result, the present MRAC was found to be closer to AC by TCT and CT than by the Chang method since MRAC, due to exact imaging of the head contour, was independent on radiation count, and was thought to be useful for improving the precision of CBF SPECT. (K.T.)

  2. Myocardial CT perfusion imaging and SPECT for the diagnosis of coronary artery disease

    DEFF Research Database (Denmark)

    George, Richard T; Mehra, Vishal C; Chen, Marcus Y

    2014-01-01

    %, respectively, for SPECT. CONCLUSION: The overall performance of myocardial CT perfusion imaging in the diagnosis of anatomic CAD (stenosis ≥50%), as demonstrated with the Az, was higher than that of SPECT and was driven in part by the higher sensitivity for left main and multivessel disease.......PURPOSE: To compare the diagnostic performance of myocardial computed tomographic (CT) perfusion imaging and single photon emission computed tomography (SPECT) perfusion imaging in the diagnosis of anatomically significant coronary artery disease (CAD) as depicted at invasive coronary angiography....... MATERIALS AND METHODS: This study was approved by the institutional review board. Written informed consent was obtained from all patients. Sixteen centers enrolled 381 patients from November 2009 to July 2011. Patients underwent rest and adenosine stress CT perfusion imaging and rest and either exercise...

  3. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru [Chiba Univ. (Japan). School of Medicine

    1994-09-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author).

  4. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru

    1994-01-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author)

  5. SPECT and PET Serve as Molecular Imaging Techniques and in Vivo Biomarkers for Brain Metastases

    Directory of Open Access Journals (Sweden)

    Barbara Palumbo

    2014-06-01

    Full Text Available Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI is discussed.

  6. Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging

    International Nuclear Information System (INIS)

    Knešaurek, K.; Heiba, S.; Kolker, D.; Vatti, S.

    2015-01-01

    The purpose of our study was to correctly fuse MRI and SPECT 111 In WBC and 99m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and 111 In WBC/ 99 m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq 111 In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7±0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. 111 In WBC/ 99 m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. In conclusion, the CT in dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT studies can be used to accurately fuse and compare 111 In WBC/ 99 m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.

  7. The EEG, CT and Tc-99m HMPAO SPECT study in patients with epilepsy

    International Nuclear Information System (INIS)

    Tovuudorj, A.; Tsagaankhuu, G.; Onkhuudai, P.; Tsevelmaa, L.; Sereegotov, E.; Enkhtuya, B.

    2007-01-01

    Full text: We have put an objective of studying the EEG and neuroimaging diagnostic indexes (CT, SPECT) in patients with partial seizures during interictal period. Methods: In our study a total of 35 cases were included (20 male and 15 females). In EEG studies we used the diagnostics methodology elaborated by L.R.Zenkov (1996) and in SPECT study by Payne JK (1991) and in CT investigation by Chermissan V.M (2001). Results: By EEG study the cases of interictal period of partial seizure were mostly revealed in the form of sharp waves in temporal lobe (47.62.5%). By CT study the 18 (51.4 ± 2.5 %) cases of partial seizure with normal index, 12 (34.3 ± 1.8 %) cases with dilatation of ventricles and 5 (14.3 ± 2.1%) cases of cerebral atrophy. In SPECT investigation we identified 8 (22.81.8%) cases with normal brain blood flow supply and 27 (77.2 2.0%) cases with variable degrees of hypoperfusion (AI) in the temporal lobe was reaching 233.9% (p<0.01). Conclusion: 1. On EEG analysis during interictal period of partial seizures, there were prevailing sharp-waves (47.6 ± 2.5%) at temporal location of a hemispheres. 2. The brain CT investigation during epilepsy mostly revealed the normal indexes 3. By analyzing brain SPECT during the interictal period of seizures, there were prevailing hypoperfusion degrees (AI) of blood flow to reach 23.0 ± 3.9%. (author)

  8. Preliminary application of brain perfusion SPECT imaging in schizophrenia

    International Nuclear Information System (INIS)

    Wu Zhixing; Guo Chanliu; Li Xingbao; Liang Rongxiang; Zhao Jun; Yan Tingxiu

    1996-01-01

    The clinical value of 99m Tc-ECD brain perfusion SPECT imaging was evaluated in patients with schizophrenia. 32 patients with schizophrenia and 21 normal controls were analyzed with 99m Tc-ECD SPECT. 93.8% (30/32) of the patients showed decreased regional cerebral blood flow (rCBF). There was normal rCBF in controls. In the patient group rCBF decreased significantly in bilateral frontal lobes, left temporal lobe and right basal ganglion. The rCBF of left temporal lobe was significantly lower than that of right temporal lobe. The decreasing rCBF was not significantly related to previous treatment and duration of illness. 99m Tc-ECD SPECT is useful for the study and diagnosis of patients with schizophrenia

  9. Design and evaluation of a mobile bedside PET/SPECT imaging system

    Science.gov (United States)

    Studenski, Matthew Thomas

    Patients confined to an intensive care unit, the emergency room, or a surgical suite are managed without nuclear medicine procedures such as positron emission tomography (PET) or single photon emission computed tomography (SPECT). These studies have diagnostic value which can greatly benefit the physician's treatment of the patient but require that the patient is moved to a scanner. This dissertation examines the feasibility of an economical PET/SPECT system that can be brought to the bedside of an immobile patient for imaging. We chose to focus on cardiac SPECT imaging including perfusion imaging using 99mTc tracers and viability imaging using 18F tracers first because of problems arising from positioning a detector beneath a patient's bed, a requirement for the opposed detector orientation in PET imaging. Second, SPECT imaging acquiring over the anterior 180 degrees of the patient results in reduced attenuation effects due to the heart's location in the anterior portion of the body. Four studies were done to assess the clinical feasibility of the mobile system; 1) the performance of the system was evaluated in SPECT mode at both 140 keV (99mTc tracers) and 511 keV (positron emitting tracers), 2) a dynamic cardiac phantom was used to develop and test image acquisition and processing methods for the system at both energies, 3) a high energy pinhole collimator was designed to reduce the effects of high energy photon penetration through the parallel hole collimator, and 4) we estimated the radiation dose to persons that would be in the vicinity of a patient to ensure that the effective dose is below the regulatory limit. With these studies, we show that the mobile system provides an economical means of bringing nuclear medicine to an immobile patient while staying below the regulatory dose limit to other persons. The system performed well at both 140 keV and 511 keV and provided viable images of a phantom myocardium at both energies. The system does not achieve the

  10. SPECT brain perfusion imaging in mild traumatic brain injury

    International Nuclear Information System (INIS)

    Li Juan; Liu Baojun; Zhao Feng; He Lirong; Xia Yucheng

    2003-01-01

    Objective: To study the clinical value of SPECT brain perfusion imaging after mild traumatic brain injury and to evaluate the mechanism of brain blood flow changes in the brain traumatic symptoms. Methods: SPECT 99 Tc m -ethylene cysteinate dimer (ECD) brain perfusion imaging was performed on 39 patients with normal consciousness and normal computed tomography. The study was performed on 23 patients within 3 months after the accidental injury and on 16 patients at more than 3 months post-injury. The cerebellum was used as the reference site (100% maximum value). Any decrease in cerebral perfusion in cortex or basal ganglia to below 70%, or even to below 50% in the medial temporal lobe, compared to the cerebellar reference was considered abnormal. Results: The results of 23 patients (59%) were abnormal. Among them, 20 patients showed 74 focal lesions with an average of 3.7 per patient (15 studies performed within 3 months and 8 studies performed more than 3 months after injury). The remaining 3 showed diffuse hypoperfusion (two at the early stage and one at more than 3 months after the injury). The 13 abnormal studies performed at the early stage showed 58 lesions (average, 4.5 per patient), whereas there was a reduction to an average of 2.3 per patient in the 7 patients (total 16 lesions) at more than 3 months post-injury. In the 20 patients with focal lesions, mainly the following regions were involved: frontal lobes 43.2% (32/74), basal ganglia 24.3% (18/74) and temporal lobes 17.6% (13/74). Conclusions: 1) SPECT brain perfusion imaging is more sensitive than computed tomography in detecting brain lesions of mild traumatic brain injury. 2) SPECT brain perfusion imaging is more sensitive at early stage than at late stage after injury. 3) The most common complaints were headache, dizziness, memory deficit. The patients without loss of consciousness may present brain hypoperfusion, too. 4) The changes may explain a neurological component of the patient symptoms in

  11. Regional differences between 99mTc-ECD and 99mTc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    International Nuclear Information System (INIS)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2003-01-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether 99m Tc-HMPAO or 99m Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8±6.6 years) were assigned to 99m Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6±6.7 years) to 99m Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq 99m Tc-HMPAO or 99m Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether 99m Tc-HMPAO and 99m Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  12. Design and evaluation of corn starch-bonded Rhizophora spp. particleboard phantoms for SPECT/CT imaging

    Science.gov (United States)

    Hamid, Puteri Nor Khatijah Abd; Yusof, Mohd Fahmi Mohd; Aziz Tajuddin, Abd; Hashim, Rokiah; Zainon, Rafidah

    2018-01-01

    The aim of this study was to design and evaluate of corn starch-bonded Rhizophora spp. particleboards as phantom for SPECT/CT imaging. The phantom was designed according to the Jaszczak phantom commonly used in SPECT imaging with dimension of 22 cm diameter and 18 cm length. Six inserts with different diameter were made for insertion of vials filled with 1.6 µCi/ml of 99mTc unsealed source. The particleboard phantom was scanned using SPECT/CT imaging protocol. The contrast of each vial for particleboards phantom were calculated based on the ratio of counts in radionuclide volume and phantom background and compared to Perspex® and water phantom. The results showed that contrast values for each vial in particleboard phantomis near to 1.0 and in good agreement with Perspex® and water phantoms as common phantom materials for SPECT/CT. The paired sample t-test result showed no significant difference of contrast values between images in particleboard phantoms and that in water. The overall results showed the potential of corn starch-bonded Rhizophora spp. as phantom for quality control and dosimetry works in SPECT/CT imaging.

  13. Effect of administered radioactive dose level on image quality of brain perfusion imaging with 99mTc-HMPAO

    Directory of Open Access Journals (Sweden)

    I.Armeniakos

    2008-01-01

    Full Text Available Brain perfusion imaging by means of 99mTc-labeled hexamethyl propylene amine oxime (HMPAO is a well-established Nuclear Medicine diagnostic procedure. The administered dose range recommended by the supplying company and reported in bibliography is rather wide (approximately 9.5-27 mCi. This fact necessitates further quantitative analysis of the technique, so as to minimise patient absorbed dose without compromising the examination diagnostic value. In this study, a quantitative evaluation of the radiopharmaceutical performance for different values of administered dose (10, 15, 20 mCi was carried out. Subsequently, a generic image quality index was correlated with the administered dose, to produce an overall performance indicator. Through this cost-to-benefit type analysis, the necessity of administration of higher radioactive dose levels in order to perform the specific diagnostic procedure was examined.Materials & methods: The study was based on a sample of 78 patients (56 administered with 10 mCi, 10 with 15 mCi and 12 with 20 mCi. Some patients were classified as normal, while others presented various forms of pathology. Evaluation of image quality was based on contrast, noise and contrast-to-noise ratio indicators, denoted CI, NI and CNR respectively. Calculation of all indicators was based on wavelet transform. An overall performance indicator (denoted PI, produced by the ratio of CNR by administered dose, was also calculated.Results: Calculation of skewness parameter revealed the normality of CI, NI and non-normality of CNR, PI populations. Application of appropriate statistical tests (analysis of variance for normal and Kruskal-Wallis test for non-normal populations showed that there is a statistically significant difference in CI (p0.05 values. Application of Tukey test for normal populations CI, NI led to the conclusion that CI(10 mCi = CI(20 mCiNI(20 mCi, while NI(15 mCi can not be characterised. Finally, application of non

  14. of Hypoxia-Inducible Factor-1α Activity by the Fusion of High-Resolution SPECT and Morphological Imaging Tests

    Directory of Open Access Journals (Sweden)

    Hirofumi Fujii

    2012-01-01

    Full Text Available Purpose. We aimed to clearly visualize heterogeneous distribution of hypoxia-inducible factor 1α (HIF activity in tumor tissues in vivo. Methods. We synthesized of 125I-IPOS, a 125I labeled chimeric protein probe, that would visualize HIF activity. The biodistribution of 125I-IPOS in FM3A tumor-bearing mice was evaluated. Then, the intratumoral localization of this probe was observed by autoradiography, and it was compared with histopathological findings. The distribution of 125I-IPOS in tumors was imaged by a small animal SPECT/CT scanner. The obtained in vivo SPECT-CT fusion images were compared with ex vivo images of excised tumors. Fusion imaging with MRI was also examined. Results. 125I-IPOS well accumulated in FM3A tumors. The intratumoral distribution of 125I-IPOS by autoradiography was quite heterogeneous, and it partially overlapped with that of pimonidazole. High-resolution SPECT-CT fusion images successfully demonstrated the heterogeneity of 125I-IPOS distribution inside tumors. SPECT-MRI fusion images could give more detailed information about the intratumoral distribution of 125I-IPOS. Conclusion. High-resolution SPECT images successfully demonstrated heterogeneous intratumoral distribution of 125I-IPOS. SPECT-CT fusion images, more favorably SPECT-MRI fusion images, would be useful to understand the features of heterogeneous intratumoral expression of HIF activity in vivo.

  15. Clinical evaluation of {sup 99m}Tc-HMPAO labeled leukocyte imaging in ulcerative colitis

    Energy Technology Data Exchange (ETDEWEB)

    Saitoh, Yasuhiro; Aburano, Tamio; Takashio, Tetsuya; Shuke, Noriyuki; Ayabe, Tokiyoshi; Nomura, Masashi; Kohgo, Yutaka; Ishikawa, Yukio; Satoh, Junichi [Asahikawa Medical Coll., Hokkaido (Japan)

    1996-07-01

    Inflammatory imaging using {sup 99m}Tc-HMPAO-labeled mixed leukocytes was assessed for use in treating 11 cases diagnosed as ulcerative colitis: 10 cases with total colitis and 1 with left-sided colitis. They consisted of 8 patients with relapse-remitting type and 3 with chronic continuous type. Radionuclide abdominal images were obtained at 1 hr, 4 hr and 24 hr after intravenous injection of 200 MBq prepared {sup 99m}Tc leukocytes. Obvious colonic activity noted at 4 hr served as the basis for positive comparative criterion in the present study. The diagnostic efficacy of radionuclide imaging was compared with endoscopic findings (based on Matts` classification) and the clinical manifestations as reference. The sensitivity and specificity of this imaging were 83.3% and 85.7%, respectively, these values being consistent with endoscopic findings and clinical manifestations at sites of disease activity. All of positive images changed to negative after treatment by leukocyte apheresis or glucocorticoid. Based on these results, {sup 99m}Tc leukocyte imaging can be used to accurately evaluate severity and treatment response in ulcerative colitis. Leukocytes may be closely related to the pathogenesis of ulcerative colitis. (author)

  16. Registration of SPECT, PET and/or X-ray CT images in patients with lung cancer

    International Nuclear Information System (INIS)

    Uemura, K.; Toyama, H.; Miyamoto, T.; Yoshikawa, K.; Mori, Y.

    2002-01-01

    Aim: In order to evaluate the therapeutic gain of heavy ion therapy performed on patients with lung cancer, the regional pulmonary functions and the amount of radio tracer accumulation to the tumor, we are investigated by using the region of interest based on anatomical information obtained from X-ray CT. There are many registration techniques for brain images, but not so much for the other organ images that we have studied registration of chest SPECT, PET and/or X-ray CT images. Materials and Methods: Perfusion, ventilation and blood pool images with Tc 99m labeled radiopharmaceuticals and SPECT, tumor images with 11 C-methionine and PET and X-ray CT scans were performed on several patients with lung cancer before and after heavy ion therapy. The registrations of SPECT-CT, PET-CT and CT-CT were performed by using AMIR (Automatic Multimodality Image Registration), which was developed by Babak et al. for registration of brain images. In a case of SPECT-CT registration, each of the three functional images was registered to the X-ray CT image, and the accuracy of each registration was compared. In the studies of PET-CT registration, the transmission images and X-ray CT images were registered at first, because the 11 C-methionine PET images bear little resemblance to the underlying anatomical images. Next, the emission images were realigned by using the same registration parameters. The X-ray CT images obtained from a single subject at the different time were registered to the first X-ray CT images, respectively. Results: In the SPECT-CT registration, the blood pool-CT registration is the best among three SPECT images in visual inspection by radiologists. In the PET-CT registration, the Transmission-CT registrations got good results. Therefore, Emission-CT registrations also got good results. In the CT-CT registration, the X-ray CT images obtained from a single subject at the different time were superimposed well each other except for lower lobe. As the results, it was

  17. Geometric Calibration and Image Reconstruction for a Segmented Slant-Hole Stationary Cardiac SPECT System.

    Science.gov (United States)

    Mao, Yanfei; Yu, Zhicong; Zeng, Gengsheng L

    2015-06-01

    A dedicated stationary cardiac single-photon emission computed tomography (SPECT) system with a novel segmented slant-hole collimator has been developed. The goal of this paper is to calibrate this new imaging geometry with a point source. Unlike the commercially available dedicated cardiac SPECT systems, which are specialized and can be used only to image the heart, our proposed cardiac system is based on a conventional SPECT system but with a segmented slant-hole collimator replacing the collimator. For a dual-head SPECT system, 2 segmented collimators, each with 7 sections, are arranged in an L-shaped configuration such that they can produce a complete cardiac SPECT image with only one gantry position. A calibration method was developed to estimate the geometric parameters of each collimator section as well as the detector rotation radius, under the assumption that the point source location is calculated using the central-section data. With a point source located off the rotation axis, geometric parameters for each collimator section can be estimated independently. The parameters estimated individually are further improved by a joint objective function that uses all collimator sections simultaneously and incorporates the collimator symmetry information. Estimation results and images reconstructed from estimated parameters are presented for both simulated and real data acquired from a prototype collimator. The calibration accuracy was validated by computer simulations with an error of about 0.1° for the slant angles and about 1 mm for the rotation radius. Reconstructions of a heart-insert phantom did not show any image artifacts of inaccurate geometric parameters. Compared with the detector's intrinsic resolution, the estimation error is small and can be ignored. Therefore, the accuracy of the calibration is sufficient for cardiac SPECT imaging. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. Evaluating performance of a pixel array semiconductor SPECT system for small animal imaging

    International Nuclear Information System (INIS)

    Kubo, Naoki; Zhao, Songji; Fujiki, Yutaka

    2005-01-01

    Small animal imaging has recently been focused on basic nuclear medicine. We have designed and built a small animal SPECT imaging system using a semiconductor camera and a newly designed collimator. We assess the performance of this system for small object imaging. We employed an MGC 1500 (Acrorad Co.) camera including a CdTe semiconductor. The pixel size was 1.4 mm/pixel. We designed and produced a parallel-hole collimator with 20-mm hole length. Our SPECT system consisted of a semiconductor camera with the subject holder set on an electric rotating stage controlled by a computer. We compared this system with a conventional small animal SPECT system comprising a SPECT-2000H scanner with four Anger type cameras and pinhole collimators. The count rate linearity for estimation of the scatter was evaluated for a pie-chart phantom containing different concentrations of 99m Tc. We measured the full width half maximum (FWHM) of the 99m Tc SPECT line source along with scatter. The system volume sensitivity was examined using a flood source phantom which was 35 mm long with a 32-mm inside diameter. Additionally, an in vivo myocardial perfusion SPECT study was performed with a rat. With regards to energy resolution, the semiconductor camera (5.6%) was superior to the conventional Anger type camera (9.8%). In the count rate linearity evaluation, the regression lines of the SPECT values were y=0.019x+0.031 (r 2 =0.999) for our system and y=0.018x+0.060 (r 2 =0.997) for the conventional system. Thus, the scatter count using the semiconductor camera was less than that using the conventional camera. FWHMs of our system and the conventional system were 2.9±0.1 and 2.0±0.1 mm, respectively. Moreover, the system volume sensitivity of our system [0.51 kcps/(MBq/ml)/cm] was superior to that of the conventional system [0.44 kcps/(MBq/ml)/cm]. Our system provided clear images of the rat myocardium, sufficient for practical use in small animal imaging. Our SPECT system, utilizing a

  19. Assessment of technetium-99m technegas scintigraphy for ventilatory impairment in pulmonary emphysema. Comparison of planar and SPECT images

    International Nuclear Information System (INIS)

    Satoh, Katashi; Tanabe, Masatada; Takahashi, Kazue

    1997-01-01

    Pulmonary emphysema can be diagnosed easily by X-ray CT (CT) as a low attenuation area. Recently Tc-99m-Technegas (Technegas) has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of planar and SPECT images by using Technegas scintigraphy in patients with pulmonary emphysema. Technegas scintigraphy, CT and pulmonary function tests were performed in 20 patients (males, age 32-78 years). We classified the findings of Technegas images into 4 grades. Comparing planar and SPECT images of Technegas, more detailed findings were shown by SPECT than by planar images in mild cases (6 cases, 30%). In more severe cases, findings of SPECT and planar images were equivalent (14 cases, 70%). The degree of abnormal findings obtained by SPECT was equivalent to that obtained by CT in severe cases (6 cases, 30%). SPECT should be excluded in advanced stages as indicated by planar images. (author)

  20. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  1. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  2. Combining SPECT and Quantitative EEG Analysis for the Automated Differential Diagnosis of Disorders with Amnestic Symptoms

    Directory of Open Access Journals (Sweden)

    Yvonne Höller

    2017-09-01

    Full Text Available Single photon emission computed tomography (SPECT and Electroencephalography (EEG have become established tools in routine diagnostics of dementia. We aimed to increase the diagnostic power by combining quantitative markers from SPECT and EEG for differential diagnosis of disorders with amnestic symptoms. We hypothesize that the combination of SPECT with measures of interaction (connectivity in the EEG yields higher diagnostic accuracy than the single modalities. We examined 39 patients with Alzheimer's dementia (AD, 69 patients with depressive cognitive impairment (DCI, 71 patients with amnestic mild cognitive impairment (aMCI, and 41 patients with amnestic subjective cognitive complaints (aSCC. We calculated 14 measures of interaction from a standard clinical EEG-recording and derived graph-theoretic network measures. From regional brain perfusion measured by 99mTc-hexamethyl-propylene-aminoxime (HMPAO-SPECT in 46 regions, we calculated relative cerebral perfusion in these patients. Patient groups were classified pairwise with a linear support vector machine. Classification was conducted separately for each biomarker, and then again for each EEG- biomarker combined with SPECT. Combination of SPECT with EEG-biomarkers outperformed single use of SPECT or EEG when classifying aSCC vs. AD (90%, aMCI vs. AD (70%, and AD vs. DCI (100%, while a selection of EEG measures performed best when classifying aSCC vs. aMCI (82% and aMCI vs. DCI (90%. Only the contrast between aSCC and DCI did not result in above-chance classification accuracy (60%. In general, accuracies were higher when measures of interaction (i.e., connectivity measures were applied directly than when graph-theoretical measures were derived. We suggest that quantitative analysis of EEG and machine-learning techniques can support differentiating AD, aMCI, aSCC, and DCC, especially when being combined with imaging methods such as SPECT. Quantitative analysis of EEG connectivity could become

  3. Effects of cross talk on dual energy SPECT imaging between [sup 123]I-BMIPP and [sup 201]Tl

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Masato; Narita, Hitoshi; Yamamoto, Juro; Fukutake, Naoshige; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Fukuchi, Minoru (Hyogo College of Medicine, Nishinomiya (Japan))

    1994-01-01

    The study was undertaken to determine how much cross talk influences the visual assessment of dual energy single photon emission computed tomographic (SPECT) images with iodine 123 beta-methyl-p-iodophenylpentadecanoic acid (I-123 BMIPP) and thallium-201 in 15 patients with acute myocardial infarction. After single SPECT with I-123 BMIPP was undertaken, simultaneous dual SPECT with I-123 BMIPP and Tl-201 were undertaken in all patients. Three patients also underwent single SPECT with Tl-201. I-123 BMIPP and Tl-201 uptake was graded in four-score for the comparison between single and dual SPECT images. There was good correlation between dual energy SPECT and both single I-123 BMIPP SPECT (pS=0.97) and single Tl-201 SPECT (pS=0.59). Uptake scores were increased on dual energy SPECT, compared with single I-123 SPECT (8 out of 132 segments) and single Tl-201 SPECT (12 out of 36 segments). Overall, there was a comparatively well correlation between single SEPCT with either I-123 BMIPP or Tl-201 and dual energy SPECT images. However, one tracer uptake sometimes increased in the other tracer defect areas. This was noticeable when I-123 BMIPP exerted an effect on Tl-201. (N.K.).

  4. High-resolution single photon planar and spect imaging of brain and neck employing a system of two co-registered opposed gamma imaging heads

    Science.gov (United States)

    Majewski, Stanislaw [Yorktown, VA; Proffitt, James [Newport News, VA

    2011-12-06

    A compact, mobile, dedicated SPECT brain imager that can be easily moved to the patient to provide in-situ imaging, especially when the patient cannot be moved to the Nuclear Medicine imaging center. As a result of the widespread availability of single photon labeled biomarkers, the SPECT brain imager can be used in many locations, including remote locations away from medical centers. The SPECT imager improves the detection of gamma emission from the patient's head and neck area with a large field of view. Two identical lightweight gamma imaging detector heads are mounted to a rotating gantry and precisely mechanically co-registered to each other at 180 degrees. A unique imaging algorithm combines the co-registered images from the detector heads and provides several SPECT tomographic reconstructions of the imaged object thereby improving the diagnostic quality especially in the case of imaging requiring higher spatial resolution and sensitivity at the same time.

  5. Molecular Imaging of Hydrolytic Enzymes Using PET and SPECT.

    Science.gov (United States)

    Rempel, Brian P; Price, Eric W; Phenix, Christopher P

    2017-01-01

    Hydrolytic enzymes are a large class of biological catalysts that play a vital role in a plethora of critical biochemical processes required to maintain human health. However, the expression and/or activity of these important enzymes can change in many different diseases and therefore represent exciting targets for the development of positron emission tomography (PET) and single-photon emission computed tomography (SPECT) radiotracers. This review focuses on recently reported radiolabeled substrates, reversible inhibitors, and irreversible inhibitors investigated as PET and SPECT tracers for imaging hydrolytic enzymes. By learning from the most successful examples of tracer development for hydrolytic enzymes, it appears that an early focus on careful enzyme kinetics and cell-based studies are key factors for identifying potentially useful new molecular imaging agents.

  6. Small animal SPECT and its place in the matrix of molecular imaging technologies

    International Nuclear Information System (INIS)

    Meikle, Steven R; Kench, Peter; Kassiou, Michael; Banati, Richard B

    2005-01-01

    Molecular imaging refers to the use of non-invasive imaging techniques to detect signals that originate from molecules, often in the form of an injected tracer, and observe their interaction with a specific cellular target in vivo. Differences in the underlying physical principles of these measurement techniques determine the sensitivity, specificity and length of possible observation of the signal, characteristics that have to be traded off according to the biological question under study. Here, we describe the specific characteristics of single photon emission computed tomography (SPECT) relative to other molecular imaging technologies. SPECT is based on the tracer principle and external radiation detection. It is capable of measuring the biodistribution of minute ( -10 molar) concentrations of radio-labelled biomolecules in vivo with sub-millimetre resolution and quantifying the molecular kinetic processes in which they participate. Like some other imaging techniques, SPECT was originally developed for human use and was subsequently adapted for imaging small laboratory animals at high spatial resolution for basic and translational research. Its unique capabilities include (i) the ability to image endogenous ligands such as peptides and antibodies due to the relative ease of labelling these molecules with technetium or iodine (ii) the ability to measure relatively slow kinetic processes (compared with positron emission tomography, for example) due to the long half-life of the commonly used isotopes and (iii) the ability to probe two or more molecular pathways simultaneously by detecting isotopes with different emission energies. In this paper, we review the technology developments and design tradeoffs that led to the current state-of-the-art in SPECT small animal scanning and describe the position SPECT occupies within the matrix of molecular imaging technologies. (topical review)

  7. SPECT imaging of 131I (364 keV): importance of collimation

    International Nuclear Information System (INIS)

    Clarke, L.P.; Saw, C.B.; Leong, L.K.; Serafini, A.N.

    1985-01-01

    A low sensitivity medium energy collimator (LSMEC) designed with thick septa and long bore (theoretical leakage 131 I for a SPECT system operated in both planar and tomographic imaging modes. The collimator was designed to minimize the influence of photon penetration on spatial resolution, in particular the resolution index FWTM. Overall spatial resolution for the planar imaging mode at 10 cm from the collimator face was found to be 11.6 mm FWHM and 21.6 mm FWTM. The corresponding transverse plane and slice thickness resolution was of the order of 17 mm FWHM and 31 mm FWTM, for a radius of rotation of 16 cm. A SPECT resolution phantom was imaged. Two quadrants of cold rods were well resolved, with rod dimensions of 16 and 12.7 mm respectively, the resolution being comparable to that obtained using 99 Tcsup(m) (140 keV) and a low-energy high-resolution collimator. NEMA sensitivity obtained was 75 cpm/μCi 131 I. The resolution measurements obtained suggest that this collimator should be useful for SPECT imaging with 131 I in either radioimmunoimaging or radioimmunotherapy. (author)

  8. GATE simulation of a new design of pinhole SPECT system for small animal brain imaging

    International Nuclear Information System (INIS)

    Ozsahin, D. Uzun; Bläckberg, L.; Fakhri, G. El; Sabet, H.

    2017-01-01

    Small animal SPECT imaging has gained an increased interest over the past decade since it is an excellent tool for developing new drugs and tracers. Therefore, there is a huge effort on the development of cost-effective SPECT detectors with high capabilities. The aim of this study is to simulate the performance characteristics of new designs for a cost effective, stationary SPECT system dedicated to small animal imaging with a focus on mice brain. The conceptual design of this SPECT system platform, Stationary Small Animal SSA-SPECT, is to use many pixelated CsI:TI detector modules with 0.4 mm × 0.4 mm pixels in order to achieve excellent intrinsic detector resolution where each module is backed by a single pinhole collimator with 0.3 mm hole diameter. In this work, we present the simulation results of four variations of the SSA-SPECT platform where the number of detector modules and FOV size is varied while keeping the detector size and collimator hole size constant. Using the NEMA NU-4 protocol, we performed spatial resolution, sensitivity, image quality simulations followed by a Derenzo-like phantom evaluation. The results suggest that all four SSA-SPECT systems can provide better than 0.063% system sensitivity and < 1.5 mm FWHM spatial resolution without resolution recovery or other correction techniques. Specifically, SSA-SPECT-1 showed a system sensitivity of 0.09% in combination with 1.1 mm FWHM spatial resolution.

  9. A Silicon SPECT System for Molecular Imaging of the Mouse Brain.

    Science.gov (United States)

    Shokouhi, Sepideh; Fritz, Mark A; McDonald, Benjamin S; Durko, Heather L; Furenlid, Lars R; Wilson, Donald W; Peterson, Todd E

    2007-01-01

    We previously demonstrated the feasibility of using silicon double-sided strip detectors (DSSDs) for SPECT imaging of the activity distribution of iodine-125 using a 300-micrometer thick detector. Based on this experience, we now have developed fully customized silicon DSSDs and associated readout electronics with the intent of developing a multi-pinhole SPECT system. Each DSSD has a 60.4 mm × 60.4 mm active area and is 1 mm thick. The strip pitch is 59 micrometers, and the readout of the 1024 strips on each side gives rise to a detector with over one million pixels. Combining four high-resolution DSSDs into a SPECT system offers an unprecedented space-bandwidth product for the imaging of single-photon emitters. The system consists of two camera heads with two silicon detectors stacked one behind the other in each head. The collimator has a focused pinhole system with cylindrical-shaped pinholes that are laser-drilled in a 250 μm tungsten plate. The unique ability to collect projection data at two magnifications simultaneously allows for multiplexed data at high resolution to be combined with lower magnification data with little or no multiplexing. With the current multi-pinhole collimator design, our SPECT system will be capable of offering high spatial resolution, sensitivity and angular sampling for small field-of-view applications, such as molecular imaging of the mouse brain.

  10. Quality control of analogue to digital conversion circuitry for artefact-free SPECT imaging

    International Nuclear Information System (INIS)

    Gillen, G.J.; Elliott, A.T.

    1992-01-01

    A simple method for the objective, quantitative assessment of analogue to digital conversion (ADC) differential linearity has been developed for SPECT imaging. The analytical approach uses the fact that a differential non-linearity in the ADC will produce a non-uniformity in the digitized image which has a well defined periodicity. This can be most clearly demonstrated in the frequency space domain by determining the Fourier transform of a thick profile which is taken through the centre of a flood field image. The accuracy of the method permits deteriorations in the performance of ADCs to be detected well before significant reductions in SPECT image quality are produced. The availability of a quantitative measure of ADC performance, which can be tested objectively using a simple data acquisition method, is of value in the specification, acceptance testing and general quality control of gamma camera SPECT systems. (author)

  11. Dementia and functional cerebral imaging a reevaluation

    International Nuclear Information System (INIS)

    Steinling, M.; Lecouffe, P.; Pham, T.; Charpentier, P.; Delebvre, L.; Lavenu, I.; Pasquier, F.; Charpentier, P.; Duhamel, A.

    2000-01-01

    New concepts which concerned especially the nosologic classification of dementia as for example Dementia with Lewy Bodies (DLB) incite to revalue the main characteristics of the regional cerebral blood flow measurements studied by SPECT in several forms of dementia. SPECT analysis with 99m-Technetium HMPAO (555 MBq) was performed to 20 patients with probable DLB, 20 patients with probable Alzheimer's disease (AD) and 20 patients with Fronto-Temporal dementia (FTD). Ten pairs of regions of interest were analysed. Tracer uptake was expressed as a cortico-cerebellar activity ratio. Statistical analysis of index of fixation was performed using an univariate analysis of variance, and a selection of significative ROIs was performed using two cut-off values (80 and 82.5 %). In the FTD group, a decrease of HMPAO uptake in frontal cortical regions of interest (internal, lateral and posterior) was observed. In the DLB group the decrease of HMPAO uptake was widespread and concerned all the cortical regions of interest except the posterior frontal and occipital regions. Finally in the AD group there was a limited temporal and parietal hypoperfusion more marked on the left side without frontal hypoperfusion. This last result was obtained whatever the cognitive impairment. Consequently it seems that the frontal hypoperfusion previously reported in AD groups was induced by the fact that patients with DLB were also included because the diagnosis was not established. In conclusion we estimate that SPECT studies could be used more often in clinical research especially for a classification approach of dementia. (authors)

  12. Influences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3-dimensional brain phantom

    International Nuclear Information System (INIS)

    Akamatsu, Mana; Yamashita, Yasuo; Akamatsu, Go; Tsutsui, Yuji; Ohya, Nobuyoshi; Nakamura, Yasuhiko; Sasaki, Masayuki

    2014-01-01

    The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123 I brain SPECT obtained by the hybrid SPECT/CT device. We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray matter, white matter and bone regions. It was filled with 123 I solution (20.1 kBq/mL) in the gray matter region and with K 2 HPO 4 in the bone region. The SPECT/CT data were acquired by the hybrid SPECT/CT device. SPECT images were reconstructed by using filtered back projection with uniform attenuation correction (FBP-uAC), 3D ordered-subsets expectation-maximization with uniform AC (3D-OSEM-uAC) and 3D OSEM with CT-based non-uniform AC (3D-OSEM-CTAC). We evaluated the differences in the radioactivity distributions among these reconstruction methods using a 3D digital phantom, which was developed from CT images of the 3D brain phantom, as a reference. The normalized mean square error (NMSE) and regional radioactivity were calculated to evaluate the similarity of SPECT images to the 3D digital phantom. The NMSE values were 0.0811 in FBP-uAC, 0.0914 in 3D-OSEM-uAC and 0.0766 in 3D-OSEM-CTAC. The regional radioactivity of FBP-uAC was 11.5% lower in the middle cerebral artery territory, and that of 3D-OSEM-uAC was 5.8% higher in the anterior cerebral artery territory, compared with the digital phantom. On the other hand, that of 3D-OSEM-CTAC was 1.8% lower in all brain areas. By using the hybrid SPECT/CT device, the brain SPECT reconstructed by 3D-OSEM with CT attenuation correction can provide an accurate assessment of the distribution of brain radioactivity

  13. Voxel-Based Correlation between Coregistered Single-Photon Emission Computed Tomography and Dynamic Susceptibility Contrast Magnetic Resonance Imaging in Subjects with Suspected Alzheimer Disease

    International Nuclear Information System (INIS)

    Cavallin, L.; Axelsson, R.; Wahlund, L.O.; Oeksengard, A.R.; Svensson, L.; Juhlin, P.; Wiberg, M. Kristoffersen; Frank, A.

    2008-01-01

    Background: Current diagnosis of Alzheimer disease is made by clinical, neuropsychologic, and neuroimaging assessments. Neuroimaging techniques such as magnetic resonance imaging (MRI) and single-photon emission computed tomography (SPECT) could be valuable in the differential diagnosis of Alzheimer disease, as well as in assessing prognosis. Purpose: To compare SPECT and MRI in a cohort of patients examined for suspected dementia, including patients with no objective cognitive impairment (control group), mild cognitive impairment (MCI), and Alzheimer disease (AD). Material and Methods: 24 patients, eight with AD, 10 with MCI, and six controls, were investigated with SPECT using 99m Tc-hexamethylpropyleneamine oxime (HMPAO, Ceretec; GE Healthcare Ltd., Little Chalsont UK) and dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) with a contrast-enhancing gadobutrol formula (Gadovist; Bayer Schering Pharma, Berlin, Germany). Voxel-based correlation between coregistered SPECT and DSC-MR images was calculated. Region-of-interest (ROI) analyses were then performed in 24 different brain areas using brain registration and analysis of SPECT studies (BRASS; Nuclear Diagnostics AB, Stockholm (SE)) on both SPECT and DSC-MRI. Results: Voxel-based correlation between coregistered SPECT and DSC-MR showed a high correlation, with a mean correlation coefficient of 0.94. ROI analyses of 24 regions showed significant differences between the control group and AD patients in 10 regions using SPECT and five regions in DSC-MR. Conclusion: SPECT remains superior to DSC-MRI in differentiating normal from pathological perfusion, and DSC-MRI could not replace SPECT in the diagnosis of patients with Alzheimer disease

  14. Occipital lobe and posterior cingulate perfusion in the prediction of dementia with Lewy body pathology in a clinical sample.

    Science.gov (United States)

    Prosser, Angus M J; Tossici-Bolt, Livia; Kipps, Christopher M

    2017-12-01

    The aim of this study was to investigate the diagnostic value of occipital lobe and posterior cingulate perfusion in predicting dopamine transporter imaging outcome using a quantitative measure of analysis. In total, 99 patients with cognitive complaints who had undergone both technetium-99m-hexamethylpropyleneamine oxime single-photon emission computed tomography (Tc-HMPAO SPECT) and I ioflupane (I-FP-CIT also called DaTSCAN) imaging in a dementia diagnostic center were analyzed. Measures of perfusion were calculated from HMPAO SPECT images for the medial and lateral occipital lobe, the posterior cingulate cortex, precuneus and cuneus regions of interest using statistical parametric mapping 8. DaTSCAN images were quantified and specific binding ratios were calculated independent from HMPAO SPECT results. Statistical parametric mapping and tests of associations between perfusion and I-FP-CIT imaging were completed. Regions of interest on HMPAO yielded poor predictive values when used independently to predict I-FP-CIT status; however, the combination of normal posterior cingulate perfusion with medial and lateral occipital hypoperfusion was associated significantly with I-FP-CIT status, χ (1, N=99)=9.72, P=0.002. This combination also yielded a high positive likelihood ratio and specificity (11.1, 98%). Sensitivity was, however, low (22%). No significant perfusion differences were found when abnormal and normal I-FP-CIT groups were compared directly using voxel-based morphometry (Poccipital hypoperfusion with preserved posterior cingulate gyrus perfusion is highly specific for individuals with a positive I-FP-CIT scan in a clinical sample where diagnostic doubt exists. This regional combination, however, lacks sensitivity; therefore, absence of the sign cannot be used to rule out dementia with Lewy bodies. A positive finding provides strong evidence to rule in dementia with Lewy bodies.

  15. Preoperative localization of epileptic foci with SPECT brain perfusion imaging, electrocorticography, surgery and pathology

    International Nuclear Information System (INIS)

    Jia Shaowei; Xu Wengui; Chen Hongyan; Weng Yongmei; Yang Pinghua

    2002-01-01

    Objective: The value of preoperative localization of epileptic foci with SPECT brain perfusion imaging was investigated. Methods: The study population consisted of 23 patients with intractable partial seizures which was difficult to control with anticonvulsant for long period. In order to preoperatively locate the epileptic foci, double SPECT brain perfusion imaging was performed during interictal and ictal stage. The foci were confirmed with electrocorticography (EcoG), surgery and pathology. Results: The author checked with EcoG the foci shown by SPECT, 23 patients had all typical spike discharge. The regions of radioactivity increase in ictal matched with the abnormal electrical activity areas that EcoG showed. The spike wave originated in the corresponding cerebrum cortex instead of hyperplastic and adherent arachnoid or tumor itself. Conclusions: SPECT brain perfusion imaging contributes to distinguishing location, size, perfusion and functioning of epileptogenic foci, and has some directive function on to making out a treatment programme at preoperation

  16. Examination of statistical noise in SPECT image and sampling pitch

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Watanabe, Hiroyuki; Murakami, Tomonori; Kawakami, Kazunori; Teraoka, Satomi; Kojima, Akihiro; Matsumoto, Masanori

    2008-01-01

    Statistical noise in single photon emission computed tomography (SPECT) image was examined for its relation with total count and with sampling pitch by simulation and phantom experiment to obtain their projection data under defined conditions. The former SPECT simulation was performed on assumption of a virtual, homogeneous water column (20 cm diameter) as an absorbing mass. In the latter, used were 3D-Hoffman brain phantom (Data Spectrum Corp.) filled with 370 MBq of 99m Tc-pertechnetate solution and a facing 2-detector SPECT machine with a low-energy/high-resolution collimator, E-CAM (Siemens). Projected data by the two methods were reconstructed through the filtered back projection to make each transaxial image. The noise was evaluated by vision, by their root mean square uncertainty calculated from average count and standard deviation (SD) in the region of interest (ROI) defined in reconstructed images and by normalized mean squares calculated from the difference between the reference image obtained with common sampling pitch to and all of obtained slices of, the simulation and phantom. As a conclusion, the pitch was recommended to be set in the machine as to approximating the value calculated by the sampling theorem, though the projection counts per one angular direction were smaller with the same total time of data acquisition. (R.T.)

  17. Performance evaluation of a compact PET/SPECT/CT tri-modality system for small animal imaging applications

    International Nuclear Information System (INIS)

    Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang

    2015-01-01

    PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance

  18. TU-A-12A-02: Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images

    Energy Technology Data Exchange (ETDEWEB)

    Negahdar, M [Stanford University School of Medicine, Stanford, CA (United States); Yamamoto, T [UC Davis School of Medicine, Sacramento, CA (United States); Shultz, D; Gable, L; Shan, X; Mittra, E; Loo, B; Maxim, P [Stanford University, Stanford, CA (United States); Diehn, M [Stanford University, Palo Alto, CA (United States)

    2014-06-15

    Purpose: We propose a novel lung functional imaging method to determine the spatial distribution of xenon (Xe) gas in a single inhalation as a measure of regional ventilation. We compare Xe-CT ventilation to single-photon emission CT (SPECT) ventilation, which is the current clinical reference. Regional lung ventilation information may be useful for the diagnosis and monitoring of pulmonary diseases such as COPD, radiotherapy planning, and assessing the progression of toxicity after radiation therapy. Methods: In an IRB-approved clinical study, Xe-CT and SPECT ventilation scans were acquired for three patients including one patient with severe emphysema and two lung cancer patients treated with radiotherapy. For Xe- CT, we acquired two breath-hold single energy CT images of the entire lung with inspiration of 100% O2 and a mixture of 70% Xe and 30% O2, respectively. A video biofeedback system was used to achieve reproducible breath-holds. We used deformable image registration to align the breathhold images with each other to accurately subtract them, producing a map of the distribution of Xe as a surrogate of lung ventilation. We divided each lung into twelve parts and correlated the Hounsfield unit (HU) enhancement at each part with the SPECT ventilation count of the corresponding part of the lung. Results: The mean of the Pearson linear correlation coefficient values between the Xe-CT and ventilation SPECT count for all three patients were 0.62 (p<0.01). The Xe-CT image had a higher resolution than SPECT, and did not show central airway deposition artifacts that were present in the SPECT image. Conclusion: We developed a rapid, safe, clinically practical, and potentially widely accessible method for regional lung functional imaging. We demonstrated strong correlations between the Xe-CT ventilation image and SPECT ventilation image as the clinical reference. This ongoing study will investigate more patients to confirm this finding.

  19. TU-A-12A-02: Novel Lung Ventilation Imaging with Single Energy CT After Single Inhalation of Xenon: Comparison with SPECT Ventilation Images

    International Nuclear Information System (INIS)

    Negahdar, M; Yamamoto, T; Shultz, D; Gable, L; Shan, X; Mittra, E; Loo, B; Maxim, P; Diehn, M

    2014-01-01

    Purpose: We propose a novel lung functional imaging method to determine the spatial distribution of xenon (Xe) gas in a single inhalation as a measure of regional ventilation. We compare Xe-CT ventilation to single-photon emission CT (SPECT) ventilation, which is the current clinical reference. Regional lung ventilation information may be useful for the diagnosis and monitoring of pulmonary diseases such as COPD, radiotherapy planning, and assessing the progression of toxicity after radiation therapy. Methods: In an IRB-approved clinical study, Xe-CT and SPECT ventilation scans were acquired for three patients including one patient with severe emphysema and two lung cancer patients treated with radiotherapy. For Xe- CT, we acquired two breath-hold single energy CT images of the entire lung with inspiration of 100% O2 and a mixture of 70% Xe and 30% O2, respectively. A video biofeedback system was used to achieve reproducible breath-holds. We used deformable image registration to align the breathhold images with each other to accurately subtract them, producing a map of the distribution of Xe as a surrogate of lung ventilation. We divided each lung into twelve parts and correlated the Hounsfield unit (HU) enhancement at each part with the SPECT ventilation count of the corresponding part of the lung. Results: The mean of the Pearson linear correlation coefficient values between the Xe-CT and ventilation SPECT count for all three patients were 0.62 (p<0.01). The Xe-CT image had a higher resolution than SPECT, and did not show central airway deposition artifacts that were present in the SPECT image. Conclusion: We developed a rapid, safe, clinically practical, and potentially widely accessible method for regional lung functional imaging. We demonstrated strong correlations between the Xe-CT ventilation image and SPECT ventilation image as the clinical reference. This ongoing study will investigate more patients to confirm this finding

  20. Imaging of gene expression in live pancreatic islet cell lines using dual-isotope SPECT.

    Science.gov (United States)

    Tai, Joo Ho; Nguyen, Binh; Wells, R Glenn; Kovacs, Michael S; McGirr, Rebecca; Prato, Frank S; Morgan, Timothy G; Dhanvantari, Savita

    2008-01-01

    We are combining nuclear medicine with molecular biology to establish a sensitive, quantitative, and tomographic method with which to detect gene expression in pancreatic islet cells in vivo. Dual-isotope SPECT can be used to image multiple molecular events simultaneously, and coregistration of SPECT and CT images enables visualization of reporter gene expression in the correct anatomic context. We have engineered pancreatic islet cell lines for imaging with SPECT/CT after transplantation under the kidney capsule. INS-1 832/13 and alphaTC1-6 cells were stably transfected with a herpes simplex virus type 1-thymidine kinase-green fluorescent protein (HSV1-thymidine kinase-GFP) fusion construct (tkgfp). After clonal selection, radiolabel uptake was determined by incubation with 5-(131)I-iodo-1-(2-deoxy-2-fluoro-beta-d-arabinofuranosyl)uracil ((131)I-FIAU) (alphaTC1-6 cells) or (123)I-FIAU (INS-1 832/13 cells). For the first set of in vivo experiments, SPECT was conducted after alphaTC1-6/tkgfp cells had been labeled with either (131)I-FIAU or (111)In-tropolone and transplanted under the left kidney capsule of CD1 mice. Reconstructed SPECT images were coregistered to CT. In a second study using simultaneous acquisition dual-isotope SPECT, INS-1 832/13 clone 9 cells were labeled with (111)In-tropolone before transplantation. Mice were then systemically administered (123)I-FIAU and data for both (131)I and (111)In were acquired simultaneously. alphaTC1-6/tkgfp cells showed a 15-fold greater uptake of (131)I-FIAU, and INS-1/tkgfp cells showed a 12-fold greater uptake of (123)I-FIAU, compared with that of wild-type cells. After transplantation under the kidney capsule, both reporter gene expression and location of cells could be visualized in vivo with dual-isotope SPECT. Immunohistochemistry confirmed the presence of glucagon- and insulin-positive cells at the site of transplantation. Dual-isotope SPECT is a promising method to detect gene expression in and location of

  1. Inflammation Scan Using {sup 99m}Tc-HMPAO Labelled Leukocytes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Woo Jin; Chung, Soo Kyo; Shinn, Kyung Sub; Bahk, Yong Whee; Kim, Hoon Kyo [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1989-07-15

    Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP -32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and {sup 99m}Tc-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. {sup 99m}Tc is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HMPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plans to improve the viability of the leukocytes. Inflammation scan using {sup 99m}Tc-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with {sup 99m}Tc-HMPAO in three dogs 24 hours after inoculation of live E. Coli and S. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with {sup 99m}Tc-HMPAO in 20% cell free plasma diluted with phosphate buffer solution. Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder. Uptake of labelled leukocytes in the inflammation site was definite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio. 4). Inflammation

  2. Clinical features and 123I-FP-CIT SPECT imaging in drug-induced parkinsonism and Parkinson's disease

    International Nuclear Information System (INIS)

    Diaz-Corrales, Francisco J.; Escobar-Delgado, Teresa; Sanz-Viedma, Salome; Garcia-Solis, David; Mir, Pablo

    2010-01-01

    To determine clinical predictors and accuracy of 123 I-FP-CIT SPECT imaging in the differentiation of drug-induced parkinsonism (DIP) and Parkinson's disease (PD). Several clinical features and 123 I-FP-CIT SPECT images in 32 patients with DIP, 25 patients with PD unmasked by antidopaminergic drugs (PDu) and 22 patients with PD without a previous history of antidopaminergic treatment (PDc) were retrospectively evaluated. DIP and PD shared all clinical features except symmetry of parkinsonian signs which was more frequently observed in patients with DIP (46.9%) than in patients with PDu (16.0%, p 123 I-FP-CIT SPECT images were normal in 29 patients with DIP (90.6%) and abnormal in all patients with PD, and this imaging technique showed high levels of accuracy. DIP and PD are difficult to differentiate based on clinical signs. The precision of clinical diagnosis could be reliably enhanced by 123 I-FP-CIT SPECT imaging. (orig.)

  3. Imaging in primary progressive aphasia

    International Nuclear Information System (INIS)

    Abe, K.; Ukita, H.; Yanagihara, T.

    1997-01-01

    Primary progressive aphasia (PPA) presents with aphasia, with or without other minor cognitive dysfunction. We report five patients with PPA to show the correlation between their clinical signs and imaging findings. The patients can be divided into those with nonfluent (group 1) and those with fluent (group 2) aphasia. The characteristic speech impairment was bradylalia in group 1 and word amnesia in group 2. Impairment of comprehension was common but mild in both groups. On MRI, patients in group 1 showed predominantly left frontal and perisylvian atrophy with reduced uptake in the same region on single photon emission computed tomography (SPECT) using technetium-99m hexamethyl propyleneamine oxime ( 99m Tc HMPAO). Patients in group 2 showed left temporal atrophy involving the superior, middle and inferior temporal gyri, hippocampus and parahippocampal gyrus on MRI and reduced uptake in the same region on SPECT. These findings correlated well with the functional anatomy of speech impairment. (orig.). With 4 figs., 1 tab

  4. Imaging in primary progressive aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Abe, K. [Department of Neurology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565 (Japan); Ukita, H. [Rehabilitation Service, Osaka University Hospital, Osaka (Japan); Yanagihara, T. [Department of Neurology, Osaka University Medical School, 2-2 Yamadaoka, Suita, Osaka 565 (Japan)

    1997-08-01

    Primary progressive aphasia (PPA) presents with aphasia, with or without other minor cognitive dysfunction. We report five patients with PPA to show the correlation between their clinical signs and imaging findings. The patients can be divided into those with nonfluent (group 1) and those with fluent (group 2) aphasia. The characteristic speech impairment was bradylalia in group 1 and word amnesia in group 2. Impairment of comprehension was common but mild in both groups. On MRI, patients in group 1 showed predominantly left frontal and perisylvian atrophy with reduced uptake in the same region on single photon emission computed tomography (SPECT) using technetium-99m hexamethyl propyleneamine oxime ({sup 99m}Tc HMPAO). Patients in group 2 showed left temporal atrophy involving the superior, middle and inferior temporal gyri, hippocampus and parahippocampal gyrus on MRI and reduced uptake in the same region on SPECT. These findings correlated well with the functional anatomy of speech impairment. (orig.). With 4 figs., 1 tab.

  5. Identification of inflammatory processes in temporomandibular joint (TMJ) by {sup 99m}Tc-HMPAO in animal model; Identificacao de processos inflamatorios na articulacao temporomandibular por {sup 99m}Tc-HMPAO em modelo animal

    Energy Technology Data Exchange (ETDEWEB)

    Brasileiro, Claudia Borges; Cardoso, Valbert Nascimento; Lima, Carla Flavia de; Campos, Tarcisio Passos Ribeiro de [Minas Gerais Univ., Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares]. E-mail: campos@nuclear.ufmg.br

    2005-07-01

    Temporomandibular joint (TMJ) is a synovial joint that represents the junction of mandible with skull. TMJ and mastication muscles are affected by temporomandibular disorders (TMDs). During the last two decades the advances in imaging diagnostic of TMJ have greatly contributed to the assessment of the TMJ disorders. Labelled leukocytes with technetium- 99m hexamethyl propylene amine oxime ({sup 99m}Tc-HMPAO) represent an efficient method that generates images based in physiological and/or biochemical changes related to inflammation. The aim of this study was to investigate the potential usefulness of technetium-99m labelled leukocytes scintigraphy in the diagnosis of TMJ inflammatory process applying a rabbit TMJ arthritis model. Arthritis was induced unilaterally with an intra-articular injection of ovalbumin in left ATM. On the contra-lateral side, the same dose of saline was injected. After five days, leukocytes were labeled with HMPAO and {sup 99m}Tc-HMPAO TMJ scintigraphic images were made. After twelve days a computed tomography was realized. Scintigraphic images obtained five days after induction of TMJ inflammation showed the localization of inflammatory process. The results were expressed as cpm of activity found in left ATM and contra-lateral side. Significant differences of activity were found between inflamed articulation and contra-lateral side (P = 0,0073). In conclusion, the method of leukocytes labeled with {sup 99m}Tc showed to be sensitive in detection of inflammatory disorders of TMJ and can be of great value in early diagnostic of these disorders. (author)

  6. Resting functional imaging tools (MRS, SPECT, PET and PCT).

    Science.gov (United States)

    Van Der Naalt, J

    2015-01-01

    Functional imaging includes imaging techniques that provide information about the metabolic and hemodynamic status of the brain. Most commonly applied functional imaging techniques in patients with traumatic brain injury (TBI) include magnetic resonance spectroscopy (MRS), single photon emission computed tomography (SPECT), positron emission tomography (PET) and perfusion CT (PCT). These imaging modalities are used to determine the extent of injury, to provide information for the prediction of outcome, and to assess evidence of cerebral ischemia. In TBI, secondary brain damage mainly comprises ischemia and is present in more than 80% of fatal cases with traumatic brain injury (Graham et al., 1989; Bouma et al., 1991; Coles et al., 2004). In particular, while SPECT measures cerebral perfusion and MRS determines metabolism, PET is able to assess both perfusion and cerebral metabolism. This chapter will describe the application of these techniques in traumatic brain injury separately for the major groups of severity comprising the mild and moderate to severe group. The application in TBI and potential difficulties of each technique is described. The use of imaging techniques in children will be separately outlined. © 2015 Elsevier B.V. All rights reserved.

  7. Feasibility of Stereo-Infrared Tracking to Monitor Patient Motion During Cardiac SPECT Imaging

    OpenAIRE

    Beach, Richard D.; Pretorius, P. Hendrik; Boening, Guido; Bruyant, Philippe P.; Feng, Bing; Fulton, Roger R.; Gennert, Michael A.; Nadella, Suman; King, Michael A.

    2004-01-01

    Patient motion during cardiac SPECT imaging can cause diagnostic imaging artifacts. We investigated the feasibility of monitoring patient motion using the Polaris motion-tracking system. This system uses passive infrared reflection from small spheres to provide real-time position data with vendor stated 0.35 mm accuracy and 0.2 mm repeatability. In our configuration, the Polaris system views through the SPECT gantry toward the patient's head. List-mode event data was temporally synchronized w...

  8. Diagnosis of leg osseous infection in diabetics: place of scintigraphy of the polynuclear hydrocarbons labelled by HMPAO-{sup 99m}Tc (HMPAO-LS); Diagnostic de l`infection osseuse du pied chez le diabetique: place de la scintigraphie aux polynucleaires marques a l`HMPAO-Tc 99m (HMPAO-LS)

    Energy Technology Data Exchange (ETDEWEB)

    Devillers, A.; Moisan, A.; Hennion, F.; Poirier, J.Y.; Bourguet, P. [CRLCC Eugene Marquis, Medecine Nucleaire, CHRU Endocrinologie, Rennes (France)

    1997-12-31

    In case of leg infection in diabetics it is difficult to differentiate between a chronic osteopathy, an infection of the soft tissues and an osteomyelitis (OM). We considered of interest to evaluate by a HMPAO-LS prospective study the diagnosis of osteitis in diabetic legs. Twenty seven diabetic (DID type 1 = 11, DNID type 2 = 16) patients (19 M and 8 F, average age 64 years), clinically suspected with a leg osteo-articular infection (malum perforans or cellulitis, uni- or bi-lateral, unique or multiple lesions) were included in the study. For all of them a standard radiographic examination centered on the legs, a (3 phases) osseous scintigraphy and a HMPAO-LS were achieved over 3 days. The HMPAO-LS was considered as in favour of a OM when there was an abnormal accumulation of granulocytes concordant with a hyper-fixation by osseous scintigraphy. In case of 37 retained lesions 20 OM were proved: - 8 sites, on radiological arguments and histological and/or microbiological criteria after osseous biopsy; - 8, by the radiological examination only; - 4, on biopsy arguments, only. Seventeen lesions were not OM, of which 7 were cellulitis. The sensitivity of the HMPAO-LS was 90% with a specificity of 94%. 8/20 OM had initial normal radiographs confirming the precocity of OM diagnosis by HMPAO-LS. Twelve HMPAO-LS were effected in OM evolutive surveillance. All of them became negative on the control initial site of the healing of OM. In conclusion, the HMPAO-LS appears to be an alternative to choose in the diagnosis and in the evolution surveillance of leg OM in diabetics, particularly when the healing of the perforans softs is incomplete and the question of the osteitis healing or sequel of an anti-biotherapy is posed

  9. Multi-centre evaluation of accuracy and reproducibility of planar and SPECT image quantification. An IAEA phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Brian E. [National Institute of Standards and Technology, Gaithersburg, MD (United States); Grosev, Darko [Univ. Hospital Centre Zagreb (Croatia); Buvat, Irene [Service Hospitalier Frederic Joliot, Paris (France); and others

    2017-08-01

    Accurate quantitation of activity provides the basis for internal dosimetry of targeted radionuclide therapies. This study investigated quantitative imaging capabilities at sites with a variety of experience and equipment and assessed levels of errors in activity quantitation in Single-Photon Emission Computed Tomography (SPECT) and planar imaging. Participants from 9 countries took part in a comparison in which planar, SPECT and SPECT with X ray computed tomography (SPECT-CT) imaging were used to quantify activities of four epoxy-filled cylinders containing {sup 133}Ba, which was chosen as a surrogate for {sup 131}I. The sources, with nominal volumes of 2, 4, 6 and 23 mL, were calibrated for {sup 133}Ba activity by the National Institute of Standards and Technology, but the activity was initially unknown to the participants. Imaging was performed in a cylindrical phantom filled with water. Two trials were carried out in which the participants first estimated the activities using their local standard protocols, and then repeated the measurements using a standardized acquisition and analysis protocol. Finally, processing of the imaging data from the second trial was repeated by a single centre using a fixed protocol. In the first trial, the activities were underestimated by about 15% with planar imaging. SPECT with Chang's first order attenuation correction (Chang-AC) and SPECT-CT overestimated the activity by about 10%. The second trial showed moderate improvements in accuracy and variability. Planar imaging was subject to methodological errors, e.g., in the use of a transmission scan for attenuation correction. The use of Chang-AC was subject to variability from the definition of phantom contours. The project demonstrated the need for training and standardized protocols to achieve good levels of quantitative accuracy and precision in a multicentre setting. Absolute quantification of simple objects with no background was possible with the strictest protocol to

  10. Clinical application of SPECT in adrenal imaging with iodine-131 6 beta-iodomethyl-19-norcholesterol

    International Nuclear Information System (INIS)

    Ishimura, J.; Kawanaka, M.; Fukuchi, M.

    1989-01-01

    Forty-one patients with or without adrenocortical disorders were studied to evaluate the clinical usefulness of SPECT in adrenal imaging with I-131 Adosterol. In the SPECT images from this study, all glands with either normally functioning or hyperfunctioning adrenal cortices could be detected, while those glands with hypofunctioning adrenal cortices could not be detected. Particularly in transaxial and sagittal slices, the adrenal gland was identified posteriorly and was clearly distinguished from the gallbladder. In preliminary results using SPECT by a standard method, uptake in 68 detectable glands ranged from 1.7% to 4.9% in four glands with Cushing's syndrome, from 1.1% to 1.3% in seven glands with primary aldosteronism, and were distributed below 1.0% in the remaining glands with normally functioning adrenal cortices. These data show that it is possible to evaluate the adrenocortical functioning status simply by analyzing the SPECT images of the adrenal

  11. Regional cerebral blood flow in SPECT pattern in Parkinson's disease

    International Nuclear Information System (INIS)

    Lenart-Jankowska, D.; Junik, R.; Sowinski, J.; Gembicki, M.; Wender, M.

    1997-01-01

    The purpose of our work was to compare the regional cerebral blood flow (rCBF) in SPECT examination in Parkinson's disease with (17 cases) and without (7 cases) dementia and in various clinical stages of the disease. The patients underwent SPECT examination 5-40 min after intravenous application of HMPAO (Ceretec, Amersham) with 740 Mbq (20 mCi) pertechnate 99m Tc. SPECT was performed with a Siemens Diacam single-head rotating gamma camera coupled to a high resolution collimator and Icon computer system provided by the manufacturer. The results were defined in relative values of ROI in relation to cerebellum. Patients with Parkinson's disease showed hypoperfusion in cerebral lobes and in deep cerebral structures including the basal ganglia. Regional perfusion deficit in SPECT was seen with and without associated dementia and already in early stage of the disease. Parkinson's disease is provoked by the lesions of dopaminergic neurons of the central nervous system leading to domination of extrapyramidal symptoms. There are many indications that also the neurotransmitters associated with cognitive functions as acetylcholine demonstrate some abnormalities. However, only in some cases of Parkinson's disease dementia is the dominating symptom. Our results of regional cerebral blood flow testify that in Parkinson's disease the dysfunction of the central nervous system is more diffuse than has previously been suggested. (author)

  12. Diagnosis of leg osseous infection in diabetics: place of scintigraphy of the polynuclear hydrocarbons labelled by HMPAO-99mTc (HMPAO-LS)

    International Nuclear Information System (INIS)

    Devillers, A.; Moisan, A.; Hennion, F.; Poirier, J.Y.; Bourguet, P.

    1997-01-01

    In case of leg infection in diabetics it is difficult to differentiate between a chronic osteopathy, an infection of the soft tissues and an osteomyelitis (OM). We considered of interest to evaluate by a HMPAO-LS prospective study the diagnosis of osteitis in diabetic legs. Twenty seven diabetic (DID type 1 = 11, DNID type 2 = 16) patients (19 M and 8 F, average age 64 years), clinically suspected with a leg osteo-articular infection (malum perforans or cellulitis, uni- or bi-lateral, unique or multiple lesions) were included in the study. For all of them a standard radiographic examination centered on the legs, a (3 phases) osseous scintigraphy and a HMPAO-LS were achieved over 3 days. The HMPAO-LS was considered as in favour of a OM when there was an abnormal accumulation of granulocytes concordant with a hyper-fixation by osseous scintigraphy. In case of 37 retained lesions 20 OM were proved: - 8 sites, on radiological arguments and histological and/or microbiological criteria after osseous biopsy; - 8, by the radiological examination only; - 4, on biopsy arguments, only. Seventeen lesions were not OM, of which 7 were cellulitis. The sensitivity of the HMPAO-LS was 90% with a specificity of 94%. 8/20 OM had initial normal radiographs confirming the precocity of OM diagnosis by HMPAO-LS. Twelve HMPAO-LS were effected in OM evolutive surveillance. All of them became negative on the control initial site of the healing of OM. In conclusion, the HMPAO-LS appears to be an alternative to choose in the diagnosis and in the evolution surveillance of leg OM in diabetics, particularly when the healing of the perforans softs is incomplete and the question of the osteitis healing or sequel of an anti-biotherapy is posed

  13. Triple Detector SPECT Imaging with 99mTc-DMSA in Adult Patients with Urinary Tract Infection

    International Nuclear Information System (INIS)

    Ryu, Jin Sook; Bea, Woon Gyu; Moon, Dae Hyuk; Lee, Myung Hae; Kim, Soon Bae; Park, Su Kil; Park, Jung Sik; Hong, Chang Gi; Cho, Kyung Sik

    1992-01-01

    Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head 99m Tc-DMSA SPECT imaging in urinary tract infection. We prospectively performed 99m Tc-DMSA planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), 99m Tc-DMSA SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of 99m Tc-DMSA SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radiological studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on 99m Tc-DMSA SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on 99m Tc-DMSA SPECT imaging. Follow-up 99m Tc-DMSA SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) 99m Tc-DMSA SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. 99m Tc

  14. MRI and brain spect findings in patients with unilateral temporal lobe epilepsy and normal CT scan

    Directory of Open Access Journals (Sweden)

    P.G. Carrilho

    1994-06-01

    Full Text Available 26 patients with temporal lobe epilepsy clinically documented by several abnormal interictal surface EEGs with typical unitemporal epileptiform activity and a normal CT scan were studied. Interictal99mTC HMPAO brain SPECT and MRI were performed in all subjects. Abnormalities were shown in 61.5% of MRI (n=16 and 65.4% of SPECT (n=17. Hippocampal atrophy associated to a high signal on T2-weighted MRI slices suggesting mesial temporal sclerosis was the main finding (n=12; 75% of abnormal MRI. MRI correlated well to surface EEG in 50% (n=13. There was also a good correlation between MRI and SPECT in 30.7% (n=8. SPECT and EEG were in agreement in 57.7% (n=l5. MRI, SPECT and EEG were congruent in 26.9% (n=7. These results support the usefulness of interictal brain SPECT and MRI in detecting lateralized abnormalities in temporal lobe epilepsy. On the other hand, in two cases, interictal SPECT correlated poorly with surface EEG. This functional method should not be used isolately in the detection of temporal lobe foci. MRI is more useful than CT as a neuroimaging technique in temporal lobe epilepsy. It may detect small structural lesions and mesial temporal lobe sclerosis which are not easily seen with traditional CT scanning.

  15. [Segmentation of whole body bone SPECT image based on BP neural network].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; He, Yuanlie; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2007-10-01

    In this paper, BP neural network is used to segment whole body bone SPECT image so that the lesion area can be recognized automatically. For the uncertain characteristics of SPECT images, it is hard to achieve good segmentation result if only the BP neural network is employed. Therefore, the segmentation process is divided into three steps: first, the optimal gray threshold segmentation method is employed for preprocessing, then BP neural network is used to roughly identify the lesions, and finally template match method and symmetry-removing program are adopted to delete the wrongly recognized areas.

  16. Physiological imaging with PET and SPECT in Dementia

    Energy Technology Data Exchange (ETDEWEB)

    Jagust, W.J. (California Univ., San Francisco, CA (United States). Dept. of Neurology Lawrence Berkeley Lab., CA (United States))

    1989-10-01

    Dementia is a medical problem of increasingly obvious importance. The most common cause of dementia, Alzheimer's disease (AD) accounts for at least 50% of all cases of dementia, with multi-infarct dementia the next most common cause of the syndrome. While the accuracy of diagnosis of AD may range from 80 to 90%, there is currently no laboratory test to confirm the diagnosis. Functional imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) offer diagnostic advantages since brain function is unequivocally disturbed in all dementing illnesses. Both PET and SPECT have been utilized in the study of dementia. While both techniques rely on principles of emission tomography to produce three dimensional maps of injected radiotracers, the differences between positron and single photon emission have important consequences for the practical applications of the two procedures. This briefly reviews the technical differences between PET and SPECT, and discusses how both techniques have been used in our laboratory to elucidate the pathophysiology of dementia. 32 refs., 2 figs.

  17. Physiological imaging with PET and SPECT in Dementia

    International Nuclear Information System (INIS)

    Jagust, W.J.

    1989-10-01

    Dementia is a medical problem of increasingly obvious importance. The most common cause of dementia, Alzheimer's disease (AD) accounts for at least 50% of all cases of dementia, with multi-infarct dementia the next most common cause of the syndrome. While the accuracy of diagnosis of AD may range from 80 to 90%, there is currently no laboratory test to confirm the diagnosis. Functional imaging techniques such as positron emission tomography (PET) and single photon emission computed tomography (SPECT) offer diagnostic advantages since brain function is unequivocally disturbed in all dementing illnesses. Both PET and SPECT have been utilized in the study of dementia. While both techniques rely on principles of emission tomography to produce three dimensional maps of injected radiotracers, the differences between positron and single photon emission have important consequences for the practical applications of the two procedures. This briefly reviews the technical differences between PET and SPECT, and discusses how both techniques have been used in our laboratory to elucidate the pathophysiology of dementia. 32 refs., 2 figs

  18. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru; Aburano, Tamio

    2000-01-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by 99m Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma was

  19. SPECT in Focal Epilepsies

    Directory of Open Access Journals (Sweden)

    Roderick Duncan

    2000-01-01

    Full Text Available Brain perfusion changes during seizures were first observed in the 1930s. Single Photon Emission Computed Tomography (SPECT was developed in the 1970s, and tracers suitable for the imaging of regional cerebral perfusion (rCP became available in the 1980s. The method was first used to study rCP in the interictal phase, and this showed areas of low perfusion in a proportion of cases, mainly in patients with temporal lobe epilepsies. However, the trapping paradigm of tracers such as hexamethyl propyleneamine oxime (HMPAO provided a practicable method of studying changes in rCP during seizures, and a literature was established in the late 1980s and early 1990s showing a typical sequence of changes during and after seizures of mesial temporal lobe origin; the ictal phase was associated with large increases in perfusion throughout the temporal lobe, with first the lateral, then the mesial temporal lobe becoming hypoperfused in the postictal phase. Activation and inhibition of other structures, such as the basal ganglia and frontal cortex, were also seen. Studies of seizures originating elsewhere in the brain have shown a variety of patterns of change, according to the structures involved. These changes have been used practically to aid the process of localisation of the epileptogenic zone so that epilepsy surgery can be planned.

  20. Assessment of anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema with breath-hold SPECT-CT fusion images

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Kawakami, Yasuhiko; Iwanaga, Hideyuki; Hayashi, Noriko; Seto, Akiko; Matsunaga, Naofumi

    2008-01-01

    Anatomic relation between pulmonary perfusion and morphology in pulmonary emphysema was assessed on deep-inspiratory breath-hold (DIBrH) perfusion single-photon emission computed tomography (SPECT)-CT fusion images. Subjects were 38 patients with pulmonary emphysema and 11 non-smoker controls, who successfully underwent DIBrH and non-BrH perfusion SPECT using a dual-headed SPECT system during the period between January 2004 and June 2006. DIBrH SPECT was three-dimensionally co-registered with DIBrH CT to comprehend the relationship between lung perfusion defects and CT low attenuation areas (LAA). By comparing the appearance of lung perfusion on DIBrH with non-BrH SPECT, the correlation with the rate constant for the alveolar-capillary transfer of carbon monoxide (DLCO/VA) was compared between perfusion abnormalities on these SPECTs and LAA on CT. DIBrH SPECT provided fairly uniform perfusion in controls, but significantly enhanced perfusion heterogeneity when compared with non-BrH SPECT in pulmonary emphysema patients (P<0.001). The reliable DIBrH SPECT-CT fusion images confirmed more extended perfusion defects than LAA on CT in majority (73%) of patients. Perfusion abnormalities on DIBrH SPECT were more closely correlated with DLCO/VA than LAA on CT (P<0.05). DIBrH SPECT identifies affected lungs with perfusion abnormality better than does non-BrH SPECT in pulmonary emphysema. DIBrH SPECT-CT fusion images are useful for more accurately localizing affected lungs than morphologic CT alone in this disease. (author)

  1. A novel computer-assisted image analysis of [123I]β-CIT SPECT images improves the diagnostic accuracy of parkinsonian disorders

    International Nuclear Information System (INIS)

    Goebel, Georg; Seppi, Klaus; Wenning, Gregor K.; Poewe, Werner; Scherfler, Christoph; Donnemiller, Eveline; Warwitz, Boris; Virgolini, Irene

    2011-01-01

    The purpose of this study was to develop an observer-independent algorithm for the correct classification of dopamine transporter SPECT images as Parkinson's disease (PD), multiple system atrophy parkinson variant (MSA-P), progressive supranuclear palsy (PSP) or normal. A total of 60 subjects with clinically probable PD (n = 15), MSA-P (n = 15) and PSP (n = 15), and 15 age-matched healthy volunteers, were studied with the dopamine transporter ligand [ 123 I]β-CIT. Parametric images of the specific-to-nondisplaceable equilibrium partition coefficient (BP ND ) were generated. Following a voxel-wise ANOVA, cut-off values were calculated from the voxel values of the resulting six post-hoc t-test maps. The percentages of the volume of an individual BP ND image remaining below and above the cut-off values were determined. The higher percentage of image volume from all six cut-off matrices was used to classify an individual's image. For validation, the algorithm was compared to a conventional region of interest analysis. The predictive diagnostic accuracy of the algorithm in the correct assignment of a [ 123 I]β-CIT SPECT image was 83.3% and increased to 93.3% on merging the MSA-P and PSP groups. In contrast the multinomial logistic regression of mean region of interest values of the caudate, putamen and midbrain revealed a diagnostic accuracy of 71.7%. In contrast to a rater-driven approach, this novel method was superior in classifying [ 123 I]β-CIT-SPECT images as one of four diagnostic entities. In combination with the investigator-driven visual assessment of SPECT images, this clinical decision support tool would help to improve the diagnostic yield of [ 123 I]β-CIT SPECT in patients presenting with parkinsonism at their initial visit. (orig.)

  2. A novel computer-assisted image analysis of [123I]β-CIT SPECT images improves the diagnostic accuracy of parkinsonian disorders.

    Science.gov (United States)

    Goebel, Georg; Seppi, Klaus; Donnemiller, Eveline; Warwitz, Boris; Wenning, Gregor K; Virgolini, Irene; Poewe, Werner; Scherfler, Christoph

    2011-04-01

    The purpose of this study was to develop an observer-independent algorithm for the correct classification of dopamine transporter SPECT images as Parkinson's disease (PD), multiple system atrophy parkinson variant (MSA-P), progressive supranuclear palsy (PSP) or normal. A total of 60 subjects with clinically probable PD (n = 15), MSA-P (n = 15) and PSP (n = 15), and 15 age-matched healthy volunteers, were studied with the dopamine transporter ligand [(123)I]β-CIT. Parametric images of the specific-to-nondisplaceable equilibrium partition coefficient (BP(ND)) were generated. Following a voxel-wise ANOVA, cut-off values were calculated from the voxel values of the resulting six post-hoc t-test maps. The percentages of the volume of an individual BP(ND) image remaining below and above the cut-off values were determined. The higher percentage of image volume from all six cut-off matrices was used to classify an individual's image. For validation, the algorithm was compared to a conventional region of interest analysis. The predictive diagnostic accuracy of the algorithm in the correct assignment of a [(123)I]β-CIT SPECT image was 83.3% and increased to 93.3% on merging the MSA-P and PSP groups. In contrast the multinomial logistic regression of mean region of interest values of the caudate, putamen and midbrain revealed a diagnostic accuracy of 71.7%. In contrast to a rater-driven approach, this novel method was superior in classifying [(123)I]β-CIT-SPECT images as one of four diagnostic entities. In combination with the investigator-driven visual assessment of SPECT images, this clinical decision support tool would help to improve the diagnostic yield of [(123)I]β-CIT SPECT in patients presenting with parkinsonism at their initial visit.

  3. 99mTc-Hexamethyl Propyleneamine Oxime Brain Perfusion Single Photon Emission Computed Tomography in Characterization of Dementia: An Initial Experience in Indian Clinical Practice

    International Nuclear Information System (INIS)

    Santra, Amburanjan; Sinha, Gaurav Kumar; Neogi, Rajarshi; Thukral, Ramesh Kumar

    2014-01-01

    There is a growing health burden in developing countries due to recent trends of increasing incidence of neurodegenerative diseases. To reduce the healthcare cost and effective management of dementia illness, early diagnosis, accurate differentiation and their progression assessment is becoming crucially important. We are utilizing 99m Tc-d, l-hexamethyl propyleneamine oxime (HMPAO) brain perfusion single photon emission computed tomography (SPECT) to characterize dementia on the basis of perfusion patterns and observed significant improvement in their management. Eleven patients (median age of 60 years range of 53-83 years) with clinical suspicion of dementia underwent 99m Tc-HMPAO brain perfusion SPECT. SPECT-computed tomography acquisition done, data are reconstructed, reviewed in three view and further processed in “neurogam” to get voxel based analysis and the comparison with age based normal database and surface mapping. Final diagnosis was done with clinical correlation. Four patients are diagnosed as Alzheimer's disease, two as frontotemporal dementia, one as dementia of Lewy bodies, two as vascular dementia and two as pseudodementia. All imaging findings are well-correlated with clinical background. Brain perfusion SPECT with HMPAO was very helpful to us in characterizing the patients of dementia by its perfusion pattern

  4. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    International Nuclear Information System (INIS)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S.

    2003-01-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus

  5. Cerebral Blood Flow Changes after Shunt in Hydrocephalus after Aneurysmal Subarachnoid Hemorrhage: Analysis by statistical Parametric Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Hyun, I. Y.; Choi, W. S.; Pak, H. S. [College of Medicine, Univ. of Inhwa, Incheon (Korea, Republic of)

    2003-07-01

    The purpose of this study was to evaluate the changes of regional cerebral blood flow (rCBF) after shunt operation in patients with hydrocephalus after aneurysmal subarachnoid hemorrhage ba statistical parametric mapping (SPM). Seven patients (4 male, mean age 54 years) with hydrocephalus after aneurysmal subarachnoid hemorrhage underwent a shunt operation. Tc-99m HMPAO SPECT was performed within I week before, and 2 weeks after the shunt operation. All of the SPECT images were spatially transformed to standard space, smoothed, and globally normalized. After spatial and count normalization, rCBF of pre- and post- shunting Tc- 99m HMPAO SPECT was estimated at every voxel using t statistics. The voxels with a P value of less than 0.001 were considered to be significantly different. The shunt operation was effective in all patients. Pre-shunting Tc-99m HMPAO SPECT showed hypoperfusion, predominantly in the periventricular area. After shunt operation, periventricular low perfusion was disappeared. The results of this study show that periventricular CBF is impaired in hydrocephalus after aneurysmal subarachnoid hemorrhage. Significant increase of periventricular CBF after shunt operation suggests the evaluation of periventricular CBF by SPM might be of value for the prediction of shunt effectiveness in hydrocephalus.

  6. The Performance of Ictal Brain SPECT Localizing for Epileptogenic Zone in Neocortical Epilepsy

    International Nuclear Information System (INIS)

    Kim, Eun Sik; Lee, Dong Soo; Hyun, In Young; Chung, June Key; Lee, Myung Chul; Koh, Chang Soon; Lee, Sang Kun; Chang, Kee Hyun

    1995-01-01

    The epileptogenic zones should be localized precisely before surgical resection of these zones in intractable epilepsy. The localization is more difficult in patients with neocortical epilepsy than in patients with temporal lobe epilepsy. This study aimed at evaluation of the usefulness of ictal brain perfusion SPECT for the localization of epileptogenic zones in neocortical epilepsy. We compared the performance of ictal SPECT with MRI referring to ictal scalp electroencephalography (sEEG). Ictal 99m Tc-HMPAO SPECT were done in twenty-one patients. Ictal EEG were also obtained during video monitoring. MRI were reviewed. According to the ictal sEEG and semiology, 8 patients were frontal lobe epilepsy, 7 patients were lateral temporal lobe epilepsy, 2 patients were parietal lobe epilepsy, and 4 patients were occipital lobe epilepsy. Ictal SPECT showed hyperperfusion in 14 patients(67%) in the zones which were suspected to be epileptogenic according to ictal EEG and semiology. MRI found morphologic abnormalities in 9 patients(43%). Among the 12 patients, in whom no epileptogenic zones were revealed by MR1, ictal SPECT found zones of hyperperfusion concordant with ictal sEEG in 9 patients(75%). However, no zones of hyperperfusion were found in 4 among 9 patients who were found to have cerebromalacia, abnormal calcification and migration anomaly in MRI. We thought that ictal SPECT was useful for localization of epileptogenic zones in neocortical epilepsy and especially in patients with negative findings in MRI.

  7. Clinical application of SPECT in adrenal imaging with iodine-131 6 beta-iodomethyl-19-norcholesterol

    Energy Technology Data Exchange (ETDEWEB)

    Ishimura, J.; Kawanaka, M.; Fukuchi, M.

    1989-04-01

    Forty-one patients with or without adrenocortical disorders were studied to evaluate the clinical usefulness of SPECT in adrenal imaging with I-131 Adosterol. In the SPECT images from this study, all glands with either normally functioning or hyperfunctioning adrenal cortices could be detected, while those glands with hypofunctioning adrenal cortices could not be detected. Particularly in transaxial and sagittal slices, the adrenal gland was identified posteriorly and was clearly distinguished from the gallbladder. In preliminary results using SPECT by a standard method, uptake in 68 detectable glands ranged from 1.7% to 4.9% in four glands with Cushing's syndrome, from 1.1% to 1.3% in seven glands with primary aldosteronism, and were distributed below 1.0% in the remaining glands with normally functioning adrenal cortices. These data show that it is possible to evaluate the adrenocortical functioning status simply by analyzing the SPECT images of the adrenal.

  8. Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

    Directory of Open Access Journals (Sweden)

    Banari Bahnamiri Sh

    2015-03-01

    Full Text Available Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT device is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in SPECT imaging in nuclear medicine is the use of an appropriate collimator for a certain radiopharmaceutical feature in order to create the best image as it can be effective in the quantity of Full Width at Half Maximum (FWHM which is the main parameter in spatial resolution. Method: In this research, the simulation of the detector and collimator of SPECT imaging device, Model HD3 made by Philips Co. and the investigation of important factors on the collimator were carried out using MCNP-4c code. Results: The results of the experimental measurments and simulation calculations revealed a relative difference of less than 5% leading to the confirmation of the accuracy of conducted simulation MCNP code calculation. Conclusion: This is the first essential step in the design and modelling of new collimators used for creating high quality images in nuclear medicine

  9. Functional regional cerebral blood flow SPECT using 99mTc-HM-PAO by speech memory tasks

    International Nuclear Information System (INIS)

    Tohyama, Junko

    1993-01-01

    Using single photon emission computed tomography (SPECT) with Tc-99m HA-PAO, changes in regional cerebral blood flow (rCBF) by giving word memory and Miyake's tasks were determined for localizatin of speech memory function. Twice injection method of Tc-99m HM-PAO was used to obtain subtraction SPECT images; and positioning of the 1st and 2nd SPECT was determined by phantom study. To prevent artifacts and changes in rCBF as far as possible, the subjects were informed word fluency and Miyake's tasks sufficiently. When giving word fluency approach, an increase in rCBF was observed in both the operculum and the supratemporal convolution of dominant hemisphere. When giving Miyake's approach, it was observed predominantly in the supratemporal convolution of dominant hemisphere. Although it was also observed in the base of frontal lobe and operculum, there was no bilateral difference. An increased rCBF in the basal nucleus was more clearly observed by Miyake's than word fluency tasks without bilateral differences. There was no definitive increase in rCBF in the Papez's circuit responsible for memory and emotion by either word fluency or Miyake's tasks. In mentally mild disorder patients, an increased rCBF was observed in the same areas as those in normal subjects. In such patients having a decreased rCBF at rest, an increased rCBF was seen in the contralateral hemisphere and the surrounding areas of the lesions, suggesting compensatory mechanism. (N.K.) 65 refs

  10. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  11. Towards adapting a normal patient database for SPECT brain perfusion imaging

    International Nuclear Information System (INIS)

    Smith, N D; Soleimani, M; Mitchell, C N; Holmes, R B; Evans, M J; Cade, S C

    2012-01-01

    Single-photon emission computerized tomography (SPECT) is a tool which can be used to image perfusion in the brain. Clinicians can use such images to help diagnose dementias such as Alzheimer's disease. Due to the intrinsic stochasticity in the photon imaging system, some form of statistical comparison of an individual image with a 'normal' patient database gives a clinician additional confidence in interpreting the image. Due to the variations between SPECT camera systems, ideally a normal patient database is required for each individual system. However, cost or ethical considerations often prohibit the collection of such a database for each new camera system. Some method of adapting existing normal patient databases to new camera systems would be beneficial. This paper introduces a method which may be regarded as a 'first-pass' attempt based on 2-norm regularization and a codebook of discrete spatially stationary convolutional kernels. Some preliminary illustrative results are presented, together with discussion on limitations and possible improvements

  12. Initial experience with SPECT imaging of the brain using I-123 p-iodoamphetamine in focal epilepsy

    International Nuclear Information System (INIS)

    La Manna, M.M.; Sussman, N.M.; Harner, R.N.; Kaplan, L.R.; Hershey, B.L.; Bernstein, D.R.; Parker, J.A.; Wolodzko, J.G.; Popky, G.L.

    1986-01-01

    Twenty-three patients with complex partial seizures refractory to medical treatment were examined with routine electroencephalography (EEG), closed-circuit television EEG (CCTV-EEG), CT and MR imaging, neuropsychological tests, and interictal single photon emission CT with I-123 rho-iodoamphetamine (IMP SPECT). In three patients CT and MR imaging results correlated with the epileptogenic foci as identified on CCTV-EEG. In 21 patients SPECT identified areas of focal reduction in tracer uptake that correlated with the epileptogenic focus identified on CCTV-EEG. In addition, SPECT disclosed other areas of neurologic dysfunction as elicited on neuropsychological tests. Thus, IMP SPECT is a useful tool for localizing epileptogenic foci and their associated dynamic deficits

  13. Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT.

    Science.gov (United States)

    Cheimariotis, Grigorios-Aris; Al-Mashat, Mariam; Haris, Kostas; Aletras, Anthony H; Jögi, Jonas; Bajc, Marika; Maglaveras, Nicolaos; Heiberg, Einar

    2018-02-01

    Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p automatic quantification of wide range of measurements.

  14. A SPECT study in internal carotid artery occlusion: Discrepancies between flow image and neurologic deficits

    International Nuclear Information System (INIS)

    Moriwaki, H.; Hougaku, H.; Matsuda, I.; Kusunoki, M.; Shirai, J.

    1989-01-01

    A SPECT (single photon emission computed tomography) study in internal carotid artery (ICA) occlusion was performed in 6 patients. The validity of iodoamphetamine (IMP) SPECT study in the evaluation of cerebral blood flow (CBF) or neurologic function is still controversial. In this study, the authors showed several cases in whom SPECT images of brain were not compatible with their neurologic deficits. In 2 typical cases, a large low-density area was observed in the non-dominant hemisphere in computed tomography (CT) scan, but no apparent motor-sensory deficits in left limbs were present. In these patients, SPECT study also revealed flow reduction in the affected side of the brain. So there was a possibility that an IMP brain image could not always reflect CBF, which maintains neurologic function of the brain

  15. SPECT Imaging as a Tool for Testing and Challenging Assumptions About Transport in Porous Media

    Science.gov (United States)

    Moysey, S. M.; DeVol, T. A.; Tornai, M. P.

    2014-12-01

    Medical imaging has shown promise for unraveling the influence of physical, chemical and biological processes on contaminant transport. Micro-CT scans, for instance, are increasingly utilized to image the pore-scale structure of rocks and soils, which can subsequently be used within modeling studies. A disadvantage of micro-CT, however, is that this imaging modality does not directly detect contaminants. In contrast, Single Photon Emission Computed Tomography (SPECT) can provide the three-dimensional distribution of gamma emitting materials and is thus ideal for imaging the transport of radionuclides. SPECT is of particular interest as a tool for both directly imaging the behavior of long-lived radionuclides of interest, e.g., 99Tc and 137Cs, as well as monitoring shorter-lived isotopes as in-situ tracers of flow and biogeochemical processes. We demonstrate the potential of combining CT and SPECT imaging to improve the mechanistic understanding of flow and transport processes within a heterogeneous porous medium. In the experiment, a column was packed with 0.2mm glass beads with a cylindrical zone of 2mm glass beads embedded near the outlet; this region could be readily identified within the CT images. The column was injected with a pulse of NaCl solution spiked with 99mTcO4- and monitored using SPECT while aliquots of the effluent were used to analyze the breakthrough of both solutes. The breakthrough curves could be approximately replicated by a one-dimensional transport model, but the SPECT data revealed that the tracers migrated around the inclusion of larger beads. Although the zone of large-diameter beads was expected to act as a preferential pathway, the observed behavior could only be replicated in numerical transport simulations if this region was treated as a low-permeability zone relative to the rest of the column. This simple experiment demonstrates the potential of SPECT for investigating flow and transport phenomena within a porous medium.

  16. Peritoneal fluid causing inferior attenuation on SPECT thallium-201 myocardial imaging in women

    International Nuclear Information System (INIS)

    Rab, S.T.; Alazraki, N.P.; Guertler-Krawczynska, E.

    1988-01-01

    On SPECT thallium images, myocardial left ventricular (LV) anterior wall attenuation due to breast tissue is common in women. In contrast, in men, inferior wall counts are normally decreased compared to anterior counts. The purpose of this report is to describe cases of inferior wall attenuation of counts in women caused by peritoneal fluid, not myocardial disease. Twelve consecutive SPECT thallium myocardial studies performed in women on peritoneal dialysis, being evaluated for kidney transplant, were included in this study. For all studies, 3.5 mCi 201Tl were injected intravenously. Thirty-two images were acquired over 180 degrees (45 degrees RAO progressing to 45 degrees LPO) at 40 sec per stop. SPECT images were reviewed in short axis, horizontal long and vertical long axes. Data were also displayed in bullseye format with quantitative comparison to gender-matched normal files. Ten of 12 female patients studied had inferior wall defects on images, confirmed by bullseye display. All patients had approximately 2 liters of peritoneal fluid. Review of planar rotational views showed diaphragm elevation and fluid margin attenuations affecting left ventricular inferior wall. Thus, peritoneal fluid is a cause of inferior attenuation on 201Tl cardiac imaging

  17. Regional differences between {sup 99m}Tc-ECD and {sup 99m}Tc-HMPAO SPET in perfusion changes with age and gender in healthy adults

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Kentaro; Nakagawa, Manabu; Goto, Ryoi; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi [Department of Nuclear Medicine and Radiology, Institute of Development, Aging and Cancer, Tohoku University, 4-1 Seiryomachi Aoba-ku, 980-8575, Sendai (Japan)

    2003-11-01

    A number of studies using single-photon emission tomography (SPET) have shown perfusion changes with age in several cortical and subcortical areas, which might distort the results of perfusion imaging studies of neuropsychiatric disorders. Technetium-99m labelled ethyl cysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO) are both used as markers of cerebral perfusion, but have different pharmacokinetics and retention patterns. The aim of this study was to determine whether age and gender effects on perfusion SPET differ depending on whether {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD is used. Forty-five subjects (20 male and 25 female, mean age 52.8{+-}6.6 years) were assigned to {sup 99m}Tc-HMPAO SPET (HMPAO group), and 39 subjects (24 male and 15 female, mean age 52.6{+-}6.7 years) to {sup 99m}Tc-ECD SPET (ECD group). SPET images were obtained about 10 min after intravenous injection of approximately 800 MBq {sup 99m}Tc-HMPAO or {sup 99m}Tc-ECD using the same SPET scanner. Three-dimensional volumetric magnetic resonance imaging was performed to as7sess morphological changes in the grey matter. All image processing and statistical analyses were performed using SPM99 software. An area in the right anterior frontal lobe showed an increase in perfusion with age only in the HMPAO group, whereas areas in the bilateral retrosplenial cortex showed decreases in perfusion with age only in the ECD group; neither group showed corresponding changes in the grey matter. The present study shows that different effects of age on perfusion are observed depending on whether {sup 99m}Tc-HMPAO and {sup 99m}Tc-ECD is used. This suggests that the results of perfusion SPET are differently confounded depending on the tracer used, and that perfusion SPET with these tracers has limitations when used in research on subtle perfusion changes. (orig.)

  18. Brain SPECT of chronic fatigue syndrome (CFS): a blinded visual analysis

    International Nuclear Information System (INIS)

    Casse, R.; Chew, G.; Barnden, L.; DelFante, P.; Burnet, R.; Kwiatek, R.; Chew, J.; Behin-Ain, S.; Unger, S.

    2002-01-01

    Full text: Chronic fatigue syndrome (CFS) is a debilitating and complex disorder characterised by profound fatigue and neuropsychiatric dysfunction. Previous studies with cerebral perfusion SPECT (rCBF) scans have yielded conflicting results. Most were performed with inhomogeneous patient populations and the findings were not based on a blinded visual analysis. To address this, HMPAO SPECT on a triple head gamma camera was performed on a group of 59 subjects. This group included 32 subjects (16-61 years, 24F and 8M) with moderate CFS based on the Fukuda criteria not on medication and not depressed and 27 normal volunteers (20-56 years, 16F and 11 M). Two blinded reviewers (RC and GC) separately assessed the SPECT studies. 28 brain structures were scored as either definitely abnormal(1), possibly abnormal(2) or normal(3-5). Abnormal results were only found in the temporal lobes and brainstem. The results (Sensitivity/Specificity) based on scores 1 or 2, show that that abnormal score yielded acceptable specificity but low sensitivity. Scores 1 or 2 improved sensitivity but reduced the specificity. This shows that visual analysis of brain SPECT is not a reliable discriminant test for CFS, although quantitative analysis with statistical parametric mapping (SPM) has demonstrated significant abnormalities. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. Assessment of vascularization within hydroxyapatite ocular implant by bone scintigraphy: compartive analysis of planar and SPECT imaging

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee; Park, Soon Ah

    1999-01-01

    Complete fibrovascular ingrowth within the hydroxyapatite ocular implant is necessary for peg drilling which is performed to prevent infection and to provide motility to the ocular prosthesis. We compared planar bone scintigraphy and SPECT for the evaluation of the vascularization within hydroxyapatite ocular implants. Seventeen patients (M:F=12:5, mean age: 50.4±17.5 years) who had received a coralline hydroxyapatite ocular implant after enucleation surgery were enrolled. Patients underwent Tc-99m MDP planar bone and SPECT imaging by dual head gamma camera after their implant surgery (interval: 197±81 days). Uptake on planar and SPECT images was graded visually as less than (grade 1), equal to (grade 2), and greater than (grade 3) nasal bridge activity. Quantitative ratio of implanted to non-implanted intraorbital activity was also measured. Vascularization within hydroxyapatite implants was confirmed by slit lamp examination and ocular movement. All but three patients were considered to be vascularized within hydroxyapatite implants. In visual analysis of planar image and SPECT, grade 1 was noted in 9/18 (50%) and 6/18 (33%), respectively. Grade 2 pattern 7/18 (39%) and 4/18 (22%), and grade 3 pattern was 2/18 (11%) and 8/18 (44%) respectively. When grade 2 or 3 was considered to be positive for vascularization, the sensitivity of planar and SPECT imaging were 60% (9/15) and 80% (12/15), respectively. In 3 patients with incomplete vascularization, both planar and SPECT showed grade 1 uptake. The orbital activity ratios on planar imaging were not significantly different between complete and incomplete vascularization (1.96±9.87 vs 1.17±0.08 , p>0.05), however, it was significantly higher on SPECT in patients with complete vascularization (8.44±5.45 vs 2.20±0.87, p<0.05). In the assessment of fibrovascular ingrowth within ocular implants by Tc-99m MDP bone scintigraphy, SPECT image appears to be more effective than planar scintigraphy

  20. Study on localization diagnosis with SPECT rCBF image in childhood epilepsy: in comparison with EEG and MRI findings

    International Nuclear Information System (INIS)

    Wu Meiqian; Tang Jihong; Wu Jinchang; Shi Yizhen

    1999-01-01

    Objective: To evaluate the diagnostic value of SPECT rCBF imaging in localization of childhood epileptic foci. Methods: rCBF imaging was performed in 74 epileptic patients not in seizure and 10 epileptic patients right in seizure. EEG was performed in 84, MRI in 67 of the subjects mentioned above. All the results of three modalities were compared with each other. Results: The highest positive rate (82.14%) was found in SPECT rCBF imaging, the positive rate in EEG or MRI was 71.43 or 47.76%. The epileptic foci localized by EEG (60 abnormalities) and by MRI (32 abnormalities) were 70.59% or 58.82% in concordance with those by SPECT, respectively. Conclusions: SPECT rCBF imaging is a sensitive and effective method for epileptic foci localization. It may have some advantages over EEG and MRI in detecting and localizing epileptic foci. However, abnormal SPECT areas may cover some abnormalities which do not belong to epileptic category. A combination of these three methods (SPECT, EEG and MRI) will improve the positive rate and accuracy for localizing

  1. Characteristics of images of angiographically proven normal coronary arteries acquired by adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT with CT attenuation correction changed stepwise.

    Science.gov (United States)

    Takahashi, Teruyuki; Tanaka, Haruki; Kozono, Nami; Tanakamaru, Yoshiki; Idei, Naomi; Ohashi, Norihiko; Ohtsubo, Hideki; Okada, Takenori; Yasunobu, Yuji; Kaseda, Shunichi

    2015-04-01

    Although several studies have shown the diagnostic and prognostic value of CT-based attenuation correction (AC) of single photon emission computed tomography (SPECT) images for diagnosing coronary artery disease (CAD), this issue remains a matter of debate. To clarify the characteristics of CT-AC SPECT images that might potentially improve diagnostic performance, we analyzed images acquired using adenosine-stress thallium-201 myocardial perfusion SPECT/CT equipped with IQ[Symbol: see text]SPECT (SPECT/CT-IQ[Symbol: see text]SPECT) from patients with angiographically proven normal coronary arteries after changing the CT attenuation correction (CT-AC) in a stepwise manner. We enrolled 72 patients (Male 36, Female 36) with normal coronary arteries according to findings of invasive coronary angiography or CT-angiography within three months after a SPECT/CT study. Projection images were reconstructed at CT-AC values of (-), 40, 60, 80 and 100 % using a CT number conversion program according to our definition and analyzed using polar maps according to sex. CT attenuation corrected segments were located from the mid- and apical-inferior spread through the mid- and apical-septal regions and finally to the basal-anterior and basal- and mid-lateral regions in males, and from the mid-inferior region through the mid-septal and mid-anterior, and mid-lateral regions in females as the CT-AC values increased. Segments with maximal mean counts shifted from the apical-anterior to mid-anterolateral region under both stress and rest conditions in males, whereas such segments shifted from the apical-septal to the mid-anteroseptal region under both stress and rest conditions in females. We clarified which part of the myocardium and to which degree CT-AC affects it in adenosine-stress thallium-201 myocardial perfusion SPECT/CT-IQ[Symbol: see text]SPECT images by changing the CT-AC value stepwise. We also identified sex-specific shifts of segments with maximal mean counts that changed as

  2. New SPECT and PET Radiopharmaceuticals for Imaging Cardiovascular Disease

    Directory of Open Access Journals (Sweden)

    Oyebola O. Sogbein

    2014-01-01

    Full Text Available Nuclear cardiology has experienced exponential growth within the past four decades with converging capacity to diagnose and influence management of a variety of cardiovascular diseases. Single photon emission computed tomography (SPECT myocardial perfusion imaging (MPI with technetium-99m radiotracers or thallium-201 has dominated the field; however new hardware and software designs that optimize image quality with reduced radiation exposure are fuelling a resurgence of interest at the preclinical and clinical levels to expand beyond MPI. Other imaging modalities including positron emission tomography (PET and magnetic resonance imaging (MRI continue to emerge as powerful players with an expanded capacity to diagnose a variety of cardiac conditions. At the forefront of this resurgence is the development of novel target vectors based on an enhanced understanding of the underlying pathophysiological process in the subcellular domain. Molecular imaging with novel radiopharmaceuticals engineered to target a specific subcellular process has the capacity to improve diagnostic accuracy and deliver enhanced prognostic information to alter management. This paper, while not comprehensive, will review the recent advancements in radiotracer development for SPECT and PET MPI, autonomic dysfunction, apoptosis, atherosclerotic plaques, metabolism, and viability. The relevant radiochemistry and preclinical and clinical development in addition to molecular imaging with emerging modalities such as cardiac MRI and PET-MR will be discussed.

  3. The parallel implementation of a backpropagation neural network and its applicability to SPECT image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kerr, John Patrick [Iowa State Univ., Ames, IA (United States)

    1992-01-01

    The objective of this study was to determine the feasibility of using an Artificial Neural Network (ANN), in particular a backpropagation ANN, to improve the speed and quality of the reconstruction of three-dimensional SPECT (single photon emission computed tomography) images. In addition, since the processing elements (PE)s in each layer of an ANN are independent of each other, the speed and efficiency of the neural network architecture could be better optimized by implementing the ANN on a massively parallel computer. The specific goals of this research were: to implement a fully interconnected backpropagation neural network on a serial computer and a SIMD parallel computer, to identify any reduction in the time required to train these networks on the parallel machine versus the serial machine, to determine if these neural networks can learn to recognize SPECT data by training them on a section of an actual SPECT image, and to determine from the knowledge obtained in this research if full SPECT image reconstruction by an ANN implemented on a parallel computer is feasible both in time required to train the network, and in quality of the images reconstructed.

  4. A novel computer-assisted image analysis of [{sup 123}I]{beta}-CIT SPECT images improves the diagnostic accuracy of parkinsonian disorders

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, Georg [Innsbruck Medical University, Department of Medical Statistics, Informatics and Health Economics, Innsbruck (Austria); Seppi, Klaus; Wenning, Gregor K.; Poewe, Werner; Scherfler, Christoph [Innsbruck Medical University, Department of Neurology, Innsbruck (Austria); Donnemiller, Eveline; Warwitz, Boris; Virgolini, Irene [Innsbruck Medical University, Department of Nuclear Medicine, Innsbruck (Austria)

    2011-04-15

    The purpose of this study was to develop an observer-independent algorithm for the correct classification of dopamine transporter SPECT images as Parkinson's disease (PD), multiple system atrophy parkinson variant (MSA-P), progressive supranuclear palsy (PSP) or normal. A total of 60 subjects with clinically probable PD (n = 15), MSA-P (n = 15) and PSP (n = 15), and 15 age-matched healthy volunteers, were studied with the dopamine transporter ligand [{sup 123}I]{beta}-CIT. Parametric images of the specific-to-nondisplaceable equilibrium partition coefficient (BP{sub ND}) were generated. Following a voxel-wise ANOVA, cut-off values were calculated from the voxel values of the resulting six post-hoc t-test maps. The percentages of the volume of an individual BP{sub ND} image remaining below and above the cut-off values were determined. The higher percentage of image volume from all six cut-off matrices was used to classify an individual's image. For validation, the algorithm was compared to a conventional region of interest analysis. The predictive diagnostic accuracy of the algorithm in the correct assignment of a [{sup 123}I]{beta}-CIT SPECT image was 83.3% and increased to 93.3% on merging the MSA-P and PSP groups. In contrast the multinomial logistic regression of mean region of interest values of the caudate, putamen and midbrain revealed a diagnostic accuracy of 71.7%. In contrast to a rater-driven approach, this novel method was superior in classifying [{sup 123}I]{beta}-CIT-SPECT images as one of four diagnostic entities. In combination with the investigator-driven visual assessment of SPECT images, this clinical decision support tool would help to improve the diagnostic yield of [{sup 123}I]{beta}-CIT SPECT in patients presenting with parkinsonism at their initial visit. (orig.)

  5. Kit formulated asialoglycoprotein receptor targeting tracer based on copolymer for liver SPECT imaging

    International Nuclear Information System (INIS)

    Liu, Chang; Guo, Zhide; Zhang, Pu; Song, Manli; Zhao, Zuoquan; Wu, Xiaowei; Zhang, Xianzhong

    2014-01-01

    Introduction: Specific targeting of galactose-carrying molecule to ASGP-R in normal hepatocytes has been demonstrated before. In this study, galactosyl polystyrene was synthesized from controllable ratio of functional monomers and radio-labelled with 99m Tc by formulated kit for SPECT imaging of hepatic function. Methods: p(VLA-co-VNI)(46:54) was synthesized by free-radical copolymerization initiated by AIBN, purified by dialysis, lyophilized to kit with Tricine and TPPTS as co-ligands for 99m Tc labeling. Radiotracer 99m Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was prepared and evaluated by in vitro stability, in vivo metabolism, ex vivo biodistribution and microSPECT/CT imaging in normal KM mice. MicroSPECT/CT and microMRI imaging were also performed in C57BL/b6 mice with xenograft hepatic carcinoma for hepatic function evaluation. Results: 99m Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was obtained in high radio chemical purity (RCP) (> 99%) by using instant kit without further purification and excellent in vitro and in vivo stability. The result of biodistribution showed that liver had high uptake (90.49 ± 10.68 ID%/g) at 30 min after injection and was blocked significantly by cold copolymer. MicroSPECT imaging in normal KM mice at 1 h and 4 h after injection showed good liver retention and targeting properties. Significant defect of activity was observed in the tumor site which was confirmed by MRI imaging. Conclusion: 99m Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) with lower ratio of targeting moiety has no observable effect on the specific binding affinity and liver uptake. This makes it possible to introduce more imaging units for multi-modality imaging. Furthermore, the instant kit preparation of 99m Tc-labeling provides great potential for the evaluation of hepatocyte function in clinical application

  6. Thrombocytopenic thrombotic purpura: severe clinic with no CT, minor MRI, but a SPECT correlate

    Energy Technology Data Exchange (ETDEWEB)

    Baron, Y. [Radiologische Abteilung, Staedtisches Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Bargemann, T. [Abteilung Internistische Intensivmedizin und Dialyse am Staedtischen Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Harten, P. [Zweite Medizinische Universitaetsklinik und Poliklinik der Christian-Albrechts-Universitaet zu Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Gutschmidt, H.-J. [Abteilung Internistische Intensivmedizin und Dialyse am Staedtischen Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany)

    1999-07-01

    A 28-year-old woman with primarily therapy refractory TTP was followed neuroradiologically over 6 months. Despite pronounced neurological and neuropsychiatric symptoms including hemiparesis and aphasia she had unremarkable CT scans on two occasions. Three MRI exams showed no correlate for her neurological symptoms except a small petechial cortical hemorrhage in the right parietooccipital gyrus which may account for her TTP-related anxiety disorder. A cerebral HMPAO-SPECT showed long-standing right-sided hypoperfusion compatible with residual vasculature changes. The possible causes for the clinico-neuroradiological discrepancies are discussed in view of the literature.

  7. Thrombocytopenic thrombotic purpura: severe clinic with no CT, minor MRI, but a SPECT correlate

    International Nuclear Information System (INIS)

    Baron, Y.; Bargemann, T.; Harten, P.; Gutschmidt, H.-J.

    1999-01-01

    A 28-year-old woman with primarily therapy refractory TTP was followed neuroradiologically over 6 months. Despite pronounced neurological and neuropsychiatric symptoms including hemiparesis and aphasia she had unremarkable CT scans on two occasions. Three MRI exams showed no correlate for her neurological symptoms except a small petechial cortical hemorrhage in the right parietooccipital gyrus which may account for her TTP-related anxiety disorder. A cerebral HMPAO-SPECT showed long-standing right-sided hypoperfusion compatible with residual vasculature changes. The possible causes for the clinico-neuroradiological discrepancies are discussed in view of the literature

  8. Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic haemangiomas: the role of SPECT/CT with a hybrid camera

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio; Danieli, Roberta; Manni, Carlo; Capoccetti, Francesca; Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy)

    2004-07-01

    Delayed liver single-photon emission computed tomography (SPECT) after {sup 99m}Tc red blood cell (RBC) labelling is helpful in detecting hepatic haemangiomas; however, diagnosis can be difficult when lesions are situated adjacent to structures like the inferior vena cava, the heart or hepatic vessels, where blood activity persists. The aims of this study were to evaluate the usefulness of RBC SPECT and transmission computed tomography (RBC SPECT/CT) performed simultaneously with a hybrid imaging system for correct characterisation of hepatic lesions in patients with suspected haemangioma, and to assess the additional value of fused images compared with SPECT alone. Twelve patients with 24 liver lesions were studied. The acquisitions of both anatomical (CT) and functional (SPECT) data were performed during a single session. SPECT images were first interpreted alone and then re-evaluated after adding the transmission anatomical maps. Image fusion was successful in all patients, with perfect correspondence between SPECT and CT data, allowing the precise anatomical localisation of sites of increased blood pool activity. SPECT/CT had a significant impact on results in four patients (33.3%) with four lesions defined as indeterminate on SPECT images, accurately characterising the hot spot foci located near vascular structures. In conclusion, RBC SPECT/CT imaging using this hybrid SPECT/CT system is feasible and useful in the identification or exclusion of suspected hepatic haemangiomas located near regions with high vascular activity. (orig.)

  9. Identification of inflammatory processes in temporomandibular joint (TMJ) by 99mTc-HMPAO in animal model

    International Nuclear Information System (INIS)

    Brasileiro, Claudia Borges; Cardoso, Valbert Nascimento; Lima, Carla Flavia de; Campos, Tarcisio Passos Ribeiro de

    2005-01-01

    Temporomandibular joint (TMJ) is a synovial joint that represents the junction of mandible with skull. TMJ and mastication muscles are affected by temporomandibular disorders (TMDs). During the last two decades the advances in imaging diagnostic of TMJ have greatly contributed to the assessment of the TMJ disorders. Labelled leukocytes with technetium- 99m hexamethyl propylene amine oxime ( 99m Tc-HMPAO) represent an efficient method that generates images based in physiological and/or biochemical changes related to inflammation. The aim of this study was to investigate the potential usefulness of technetium-99m labelled leukocytes scintigraphy in the diagnosis of TMJ inflammatory process applying a rabbit TMJ arthritis model. Arthritis was induced unilaterally with an intra-articular injection of ovalbumin in left ATM. On the contra-lateral side, the same dose of saline was injected. After five days, leukocytes were labeled with HMPAO and 99m Tc-HMPAO TMJ scintigraphic images were made. After twelve days a computed tomography was realized. Scintigraphic images obtained five days after induction of TMJ inflammation showed the localization of inflammatory process. The results were expressed as cpm of activity found in left ATM and contra-lateral side. Significant differences of activity were found between inflamed articulation and contra-lateral side (P = 0,0073). In conclusion, the method of leukocytes labeled with 99m Tc showed to be sensitive in detection of inflammatory disorders of TMJ and can be of great value in early diagnostic of these disorders. (author)

  10. Quantitative analysis of d,1-HMPAO and its freeze-dried kit with HPLC

    International Nuclear Information System (INIS)

    Chen Suzhen

    1993-05-01

    A quantitative analysis method, which uses RP-HPLC (reversed phase-high performance liquid chromatography), has been established to determine the stereoisomeric purity of HMPAO and d,1-HMPAO content for d,l-HMPAO freeze-dried kit. An opitmal mobile phase is selected for obtaining chromatographic parameters that are better than those published in the references. The theoretical tray height is less than 0.06 mm. At the flowrate of 1 ml/min the total separation time is 5.5. The resolution is greater than 5. The detectable limits of meso-HMPAO and d,l-HMPAO are 1 x 10 -8 g and 5 x 10 -7 g respectively. The precision is 5% and the additional recovery is 94% ∼ 107%. This method has many advantages such as accuracy, simplicity, rapidity and stability, and it is suitable for routine inspection. It has been successfully used to determine the HMPAO stereoisomer and d,1-HMPAO of freeze-dried kit produced by China Institute of Atomic Energy and same products imported from Amersham Company of United Kingdom

  11. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  12. Interictal SPECT of rCBF is of clinical utility in the preoperative evaluation of patients with partial epilepsy

    DEFF Research Database (Denmark)

    Andersen, A R; Hansen, B A; Høgenhaven, H

    1996-01-01

    Fifty-eight patients with drug-resistant partial epilepsy were studied preoperatively by interictal rCBF measurements using 99mTc-HMPAO and a dedicated brain SPECT camera (Tomomatic 64). Follow-up of seizure outcome, using the "Engel score", was at least 3 years. The data were analyzed in a blinded...... set-up, first visually and subsequently quantitatively by an automatic regional analysis. By visual analysis 95% of the patients were considered abnormal in one part of the brain, of whom 27% were abnormal on CT, 45% on MRI and 98% on scalp EEG. Using a quantitative regional analysis subdividing each...... patients ictal SPECT of rCBF was additionally performed. In 2 cases it added further information to the patient evaluation....

  13. Interictal SPECT of rCBF is of clinical utility in the preoperative evaluation of patients with partial epilepsy

    DEFF Research Database (Denmark)

    Andersen, A.R.; Hansen, B.A.; Hogenhaven, H

    1996-01-01

    Fifty-eight patients with drug-resistant partial epilepsy were studied preoperatively by interictal rCBF measurements using 99mTc-HMPAO and a dedicated brain SPECT camera (Tomomatic 64). Follow-up of seizure outcome, using the 'Engel score', was at least 3 years. The data were analyzed in a blinded...... set-up, first visually and subsequently quantitatively by an automatic regional analysis. By visual analysis 95% of the patients were considered abnormal in one part of the brain, of whom 27% were abnormal on CT, 45% on MRI and 98% on scalp EEG. Using a quantitative regional analysis subdividing each...... patients ictal SPECT of rCBF was additionally performed. In 2 cases it added further information to the patient evaluation...

  14. Clinical study of cerebral blood flow in bilateral chronic subdural hematoma measured by {sup 99m}Tc-HMPAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru [Kushiro Neurosurgical Hospital, Hokkaido (Japan); Aburano, Tamio

    2000-08-01

    Cerebral blood flow (CBF) in 34 patients with bilateral chronic subdural hematoma was measured by {sup 99m}Tc-HMPAO SPECT before operation. The regional CBF was measured in 26 regions of the 10 cortical regions, putamen, thalamus and cerebellar hemisphere on both sides. According to the thickness of subdural hematoma, the thicker hematoma side was measured and examined as the thick hematoma side, and the other side as the thin hematoma side. Thirty four cases with bilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms :13 cases with headache (headache group), 10 cases with hemiparesis (hemiparesis group), 5 cases with tetraparesis (tetraparesis group) and 6 cases with consciousness disturbance or dementia (consciousness disturbance group), and into two groups according to the degree of midline brain shift on MRI: 14 cases of non-shifted group and 20 cases of shifted group. The average CBF of 34 patients in each region indicated a regional CBF reduction in the frontal, parietal and occipital cortices on the thin hematoma side, and in the putamen on the thick hematoma side. In the headache group, the regional CBF reduction on the thin hematoma side was found in the frontal, parietal and occipital cortices compared with the corresponding regions on the thick hematoma side, and in thalamus on the thick hematoma side. In the hemiparesis and tetraparesis groups, there was no statistically significant CBF reduction between the thick and thin hematoma sides. In the consciousness disturbance group, the CBF reduction in whole brain was remarkably significant. By the degree of the midline brain shift, the CBF reductions between the thick and thin hematoma sides were observed. Namely, in the shifted group, the CBF reductions were noted in the frontal, parietal and occipital cortices in the thin hematoma side, and in the putamen in the thick hematoma side. We concluded that the CBF reduction of bilateral chronic subdural hematoma

  15. Molecular imaging of cancer using PET and SPECT

    DEFF Research Database (Denmark)

    Kjaer, Andreas

    2006-01-01

    for molecular imaging of cancer. Especially the possibility of a quick transfer of methods developed in animals to patients (translational research) is an important strength. This article will briefly discuss the newest applications and their importance and perspective in relation to the shift in paradigm......Molecular imaging allows for the study of molecular and cellular events in the living intact organism. The nuclear medicine methodologies of positron emission tomography (PET) and single photon emission computer tomography (SPECT) posses several advantages, which make them particularly suited...

  16. [Screening with angiographic images prior to (99m)Tc-HMPAO labelled leukocyte scintigraphy in the diagnosis of periprosthetic infection].

    Science.gov (United States)

    Granados, U; Fuster, D; Soriano, A; García, S; Bori, G; Martínez, J C; Mayoral, M; Perlaza, P; Tomás, X; Pons, F

    2015-01-01

    To evaluate the impact of the angioscintigrapy of the three phase bone scan as screening method to rule out infection of the hip and knee prosthesis prior to performing the (99m)Tc-HMPAO leukocyte scintigraphy. A total of 120 (70 women, 50 men; mean age 71±11years) with clinical suspicion of hip (n=63) or knee (n=57) infection of the prosthesis and clinical suspicion of infection were evaluated prospectively. All patients underwent three-phase bone scan (angioscintigraphy, vascular and bone phase) and (99m)Tc-HMPAO-labelled white blood cell scintigraphy. Final diagnosis of infection was made by microbiological documentation or clinical follow-up for at least 12months. Eighteen out of 120 patients were diagnosed of infection of hip prosthesis (n=10) or knee prosthesis (n=8). The angioscintigraphy was positive in 15/18 infected cases and in 21/102 of the non-infected cases with a sensitivity of 83%, specificity of 79% and negative predictive value of 97%. Sensitivity and specificity of (99m)Tc-HMPAO leukocyte scintigraphy were 72% and 95%, respectively. If the leukocyte labeled scintigraphies had been used exclusively for patients with positive angioscintigraphy, this would have saved up to 70% of the (99m)Tc-HMPAO leukocyte scintigraphies performed. There were no cases of infection with positive labeled leukocyte scintigraphy and negative angioscintigraphy. Angioscintigraphy (blood flow phase of bone scan) is a useful technique for screening for hip and knee joint prosthesis infection, significantly reducing the need for (99m)Tc-HMPAO leukocyte scintigraphy without affecting the sensitivity of the technique. Copyright © 2014 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  17. A technique for manual definition of an irregular volume of interest in single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fleming, J.S.; Kemp, P.M.; Bolt, L.

    1999-01-01

    A technique is described for manually outlining a volume of interest (VOI) in a three-dimensional SPECT dataset. Regions of interest (ROIs) are drawn on three orthogonal maximum intensity projections. Image masks based on these ROIs are backprojected through the image volume and the resultant 3D dataset is segmented to produce the VOI. The technique has been successfully applied in the exclusion of unwanted areas of activity adjacent to the brain when segmenting the organ in SPECT imaging using 99m Tc HMPAO. An example of its use for segmentation in tumour imaging is also presented. The technique is of value for applications involving semi-automatic VOI definition in SPECT. (author)

  18. A Silicon SPECT System for Molecular Imaging of the Mouse Brain

    OpenAIRE

    Shokouhi, Sepideh; Fritz, Mark A.; McDonald, Benjamin S.; Durko, Heather L.; Furenlid, Lars R.; Wilson, Donald W.; Peterson, Todd E.

    2007-01-01

    We previously demonstrated the feasibility of using silicon double-sided strip detectors (DSSDs) for SPECT imaging of the activity distribution of iodine-125 using a 300-micrometer thick detector. Based on this experience, we now have developed fully customized silicon DSSDs and associated readout electronics with the intent of developing a multi-pinhole SPECT system. Each DSSD has a 60.4 mm × 60.4 mm active area and is 1 mm thick. The strip pitch is 59 micrometers, and the readout of the 102...

  19. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  20. Automated Analysis of 123I-beta-CIT SPECT Images with Statistical Probabilistic Anatomical Mapping

    International Nuclear Information System (INIS)

    Eo, Jae Seon; Lee, Hoyoung; Lee, Jae Sung; Kim, Yu Kyung; Jeon, Bumseok; Lee, Dong Soo

    2014-01-01

    Population-based statistical probabilistic anatomical maps have been used to generate probabilistic volumes of interest for analyzing perfusion and metabolic brain imaging. We investigated the feasibility of automated analysis for dopamine transporter images using this technique and evaluated striatal binding potentials in Parkinson's disease and Wilson's disease. We analyzed 2β-Carbomethoxy-3β-(4- 123 I-iodophenyl)tropane ( 123 I-beta-CIT) SPECT images acquired from 26 people with Parkinson's disease (M:F=11:15,mean age=49±12 years), 9 people with Wilson's disease (M: F=6:3, mean age=26±11 years) and 17 normal controls (M:F=5:12, mean age=39±16 years). A SPECT template was created using striatal statistical probabilistic map images. All images were spatially normalized onto the template, and probability-weighted regional counts in striatal structures were estimated. The binding potential was calculated using the ratio of specific and nonspecific binding activities at equilibrium. Voxel-based comparisons between groups were also performed using statistical parametric mapping. Qualitative assessment showed that spatial normalizations of the SPECT images were successful for all images. The striatal binding potentials of participants with Parkinson's disease and Wilson's disease were significantly lower than those of normal controls. Statistical parametric mapping analysis found statistically significant differences only in striatal regions in both disease groups compared to controls. We successfully evaluated the regional 123 I-beta-CIT distribution using the SPECT template and probabilistic map data automatically. This procedure allows an objective and quantitative comparison of the binding potential, which in this case showed a significantly decreased binding potential in the striata of patients with Parkinson's disease or Wilson's disease

  1. Collimator and energy window optimization for 90Y bremsstrahlung SPECT imaging: A SIMIND Monte Carlo study

    International Nuclear Information System (INIS)

    Roshan, Hoda Rezaei; Mahmoudian, Babak; Gharepapagh, Esmaeil; Azarm, Ahmadreza; Pirayesh Islamian, Jalil

    2016-01-01

    Treatment efficacy of radioembolization using Yttrium-90 ( 90 Y) microspheres is assessed by the 90 Y bremsstrahlung single photon emission computed tomography (SPECT) imaging following radioembolization. The radioisotopic image has the potential of providing reliable activity map of 90 Y microspheres distribution. One of the main reasons of the poor image quality in 90 Y bremsstrahlung SPECT imaging is the continuous and broad energy spectrum of the related bremsstrahlung photons. Furthermore, collimator geometry plays an impressive role in the spatial resolution, sensitivity and image contrast. Due to the relatively poor quality of the 90 Y bremsstrahlung SPECT images, we intend to optimize the medium-energy (ME) parallel-hole collimator and energy window. The Siemens e.cam gamma camera equipped with a ME collimator and a voxelized phantom was simulated by the SImulating Medical Imaging Nuclear Detectors (SIMIND) program. We used the SIMIND Monte Carlo program to generate the 90 Y bremsstrahlung SPECT projection of the digital Jaszczak phantom. The phantom consist of the six hot spheres ranging from 9.5 to 31.8 mm in diameter, which are used to evaluate the image contrast. In order to assess the effect of the energy window on the image contrast, three energy windows ranging from 60 to 160 KeV, 160 to 400 KeV, and 60 to 400 KeV were set on a 90 Y bremsstrahlung spectrum. As well, the effect of the hole diameter of a ME collimator on the image contrast and bremsstrahlung spectrum were investigated. For the fixed collimator and septa thickness values (3.28 cm and 1.14 mm, respectively), a hole diameter range (2.35–3.3 mm) was chosen based on the appropriate balance between the spatial resolution and sensitivity. The optimal energy window for 90 Y bremsstrahlung SPECT imaging was extended energy window from 60 to 400 KeV. Besides, The optimal value of the hole diameter of ME collimator was obtained 3.3 mm. Geometry of the ME parallel-hole collimator and energy

  2. Comparative methods for quantifying thyroid volume using planar imaging and SPECT

    International Nuclear Information System (INIS)

    Zaidi, H.

    1996-01-01

    Thyroid volume determination using planar imaging is a procedure often performed in routine nuclear medicine, but is hampered by several physical difficulties, in particular by structures which overlie or underlie the organ of interest. SPECT enables improved accuracy over planar imaging in the determination of the volume since it is derived from the 3-D data rather than from a 2-D projection with a certain geometric assumption regarding the thyroid configuration. By using the phantoms of known volume, it was possible to estimate the accuracy of 3 different methods of determining thyroid volume from planar imaging used in clinical routine. The experimental results demonstrate that compared with conventional scintigraphy, thyroid phantom volumes were most accurately determined with SPECT when attenuation and scatter corrections are performed which allows accurate radiation dosimetry in humans without the need for assumptions on organ size or concentrations. Poster 181. (author)

  3. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile ( 99m Tc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging

  4. Utility of SPECT imaging for determination of vertebral metastases in patients with known primary tumors

    International Nuclear Information System (INIS)

    Bushnell, D.L.; Kahn, D.; Huston, B.; Bevering, C.G.

    1995-01-01

    Determining the etiology of a focal lesion seen on bone scan in patients with primary tumors usually requires the use of other imaging procedures or biopsy. Single positron emission computed tomography (SPECT) with high resolution multidetector systems can localize the specific site of a vertebral lesion and in this way potentially differentiate between benign and metastatic disease. SPECT images of the lower thoracic and lumbar spine were reviewed for lesion location and intensity by two experienced interpreters. Follow-up data were adequate to ascertain the cause of 71 lesions seen on SPECT in 29 patients. Twenty-six of these lesions were not seen on planar images. Of the 71 lesions, 44 were benign and 27 metastatic. Of the 15 lesions where the pedicle was involved, 11 were found to metastatic. There were a total of 14 facet lesions, 9 of which were present in vertebra with no lesions at sites other than the facets. All 9 of these isolated facet lesions turned out to be benign. Lesion intensity did not distinguish benign from malignant disease. We conclude that SPECT imaging is useful in determining the etiology of focal lesions seen on bone scan in patients with a known primary tumor referred for evaluation of metastatic disease. (orig.)

  5. Performance of Myocardial Perfusion Imaging Using Multi-focus Fan Beam Collimator with Resolution Recovery Reconstruction in a Comparison with Conventional SPECT

    International Nuclear Information System (INIS)

    Matsutomo, Norikazu; Nagaki, Akio; Sasaki, Masayuki

    2014-01-01

    IQ-SPECT is an advanced high-speed SPECT modality for myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQ-SPECT with conventional SPECT in terms of performance, based on standard clinical protocols. In addition, we examined the concordance between conventional and IQ-SPECT in patients with coronary artery disease (CAD). Fifty-three patients, undergoing rest-gated MPI for the evaluation of known or suspected CAD, were enrolled in this study. In each patient, conventional SPECT ( 99m Tc-tetrofosmin, 9.6 min and 201 Tl, 12.9 min) was performed, immediately followed by IQ-SPECT, using a short acquisition time (4.3 min for 99m Tc-tetrofosmin and 6.2 min for 201 Tl). A quantitative analysis was performed on an MPI polar map, using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function including end-diastolic volume (EDV), end-systolic volume (ESV), and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. The segmental percent uptake exhibited a significant correlation between IQ-SPECT and conventional SPECT (P<0.05). The mean differences in 99m Tc-tetrofosmin studies were 1.1±6.6% (apex), 2.8±5.7% (anterior wall), 2.9±6.2% (septal wall), 4.9±6.7% (lateral wall), and 1.8±5.6% (inferior wall). Meanwhile, regarding the 201 Tl-SPECT studies, these values were 1.6±6.9%, 2.0±6.6%, 2.1±5.9%, 3.3±7.2%, and 2.4±5.8%, respectively. Although the mean LVEF in IQ-SPECT tended to be higher than that observed in conventional SPECT (conventional SPECT=64.8±11.8% and IQ-SPECT=68.3±12.1% for 99m Tc-tetrofosmin; conventional SPECT= 56.0±11.7% and IQ-SPECT=61.5±12.2% for 201 Tl), quantitative parameters were not significantly different between

  6. Fusion imaging of computed tomographic pulmonary angiography and SPECT ventilation/perfusion scintigraphy: initial experience and potential benefit

    International Nuclear Information System (INIS)

    Harris, Benjamin; Bailey, Dale; Roach, Paul; Bailey, Elizabeth; King, Gregory

    2007-01-01

    The objective of this study was to examine the feasibility of fusing ventilation and perfusion data from single-photon emission computed tomography (SPECT) ventilation perfusion (V/Q) scintigraphy together with computed tomographic pulmonary angiography (CTPA) data. We sought to determine the accuracy of this fusion process. In addition, we correlated the findings of this technique with the final clinical diagnosis. Thirty consecutive patients (17 female, 13 male) who had undergone both CTPA and SPECT V/Q scintigraphy during their admission for investigation of potential pulmonary embolism were identified retrospectively. Image datasets from these two modalities were co-registered and fused using commercial software. Accuracy of the fusion process was determined subjectively by correlation between modalities of the anatomical boundaries and co-existent pleuro-parenchymal abnormalities. In all 30 cases, SPECT V/Q images were accurately fused with CTPA images. An automated registration algorithm was sufficient alone in 23 cases (77%). Additional linear z-axis scaling was applied in seven cases. There was accurate topographical co-localisation of vascular, parenchymal and pleural disease on the fused images. Nine patients who had positive CTPA performed as an initial investigation had co-localised perfusion defects on the subsequent fused CTPA/SPECT images. Three of the 11 V/Q scans initially reported as intermediate could be reinterpreted as low probability owing to co-localisation of defects with parenchymal or pleural pathology. Accurate fusion of SPECT V/Q scintigraphy to CTPA images is possible. This technique may be clinically useful in patients who have non-diagnostic initial investigations or in whom corroborative imaging is sought. (orig.)

  7. Applications of SPECT imaging of dopaminergic neurotransmission in neuropsychiatric disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kugaya, Akira; Fujita, Masahiro; Innis, R.B. [Yale Univ., New Haven, CT (United States). School of Medicine

    2000-02-01

    Single photon emission computed tomography (SPECT) tracers selective for pre- and post-synaptic targets have allowed measurements of several aspects of dopaminergic (DA) neurotransmission. In this article, we will first review our DA transporter imaging in Parkinson's disease. We have developed the in vivo dopamine transporter (DAT) imaging with [{sup 123}I]{beta}-CIT ((1R)-2{beta}-Carbomethoxy-3{beta}-(4-iodophenyl)tropane). This method showed that patients with Parkinson's disease have markedly reduced DAT levels in striatum, which correlated with disease severity and disease progression. Second, we applied DA imaging techniques in patients with schizophrenia. Using amphetamine as a releaser of DA, we observed the enhanced DA release, which was measured by imaging D2 receptors with [{sup 123}I]IBZM (iodobenzamide), in schizophrenics. Further we developed the measurement of basal synaptic DA levels by AMPT (alpha-methyl-paratyrosine)-induced unmasking of D2 receptors. Finally, we expanded our techniques to the measurement of extrastriatal DA receptors using [{sup 123}I]epidepride. The findings suggest that SPECT is a useful technique to measure DA transmission in human brain and may further our understanding of the pathophysiology of neuropsychiatric disorders. (author)

  8. Cervical SPECT Camera for Parathyroid Imaging

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2012-08-31

    Primary hyperparathyroidism characterized by one or more enlarged parathyroid glands has become one of the most common endocrine diseases in the world affecting about 1 per 1000 in the United States. Standard treatment is highly invasive exploratory neck surgery called Parathyroidectomy. The surgery has a notable mortality rate because of the close proximity to vital structures. The move to minimally invasive parathyroidectomy is hampered by the lack of high resolution pre-surgical imaging techniques that can accurately localize the parathyroid with respect to surrounding structures. We propose to develop a dedicated ultra-high resolution (~ 1 mm) and high sensitivity (10x conventional camera) cervical scintigraphic imaging device. It will be based on a multiple pinhole-camera SPECT system comprising a novel solid state CZT detector that offers the required performance. The overall system will be configured to fit around the neck and comfortably image a patient.

  9. Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator

    International Nuclear Information System (INIS)

    Du, Yong; Frey, Eric C; Bhattacharya, Manojeet

    2014-01-01

    Simultaneous dual-radionuclide myocardial perfusion/innervation SPECT imaging can provide important information about the mismatch between scar tissue and denervated regions. The Siemens IQ-SPECT system developed for cardiac imaging uses a multifocal SMARTZOOM collimator to achieve a four-fold sensitivity for the cardiac region, compared to a typical parallel-hole low-energy high-resolution collimator, but without the data truncation that can result with conventional converging-beam collimators. The increased sensitivity allows shorter image acquisition times or reduced patient dose, making IQ-SPECT ideal for simultaneous dual-radionuclide SPECT, where reduced administrated activity is desirable in order to reduce patient radiation exposure. However, crosstalk is a major factor affecting the image quality in dual-radionuclide imaging. In this work we developed a model-based method that can estimate and compensate for the crosstalk in IQ-SPECT data. The crosstalk model takes into account interactions in the object and collimator-detector system. Scatter in the object was modeled using the effective source scatter estimation technique (ESSE), previously developed to model scatter with parallel-hole collimators. The geometric collimator-detector response was analytically modeled in the IQ-SPECT projector. The estimated crosstalk was then compensated for in an iterative reconstruction process. The new method was validated with data from both Monte Carlo simulations and physical phantom experiments. The results showed that the estimated crosstalk was in good agreement with simulated and measured results. After model-based compensation the images from simultaneous dual-radionuclide acquisitions were similar in quality to those from single-radionuclide acquisitions that did not have crosstalk contamination. The proposed model-based method can be used to improve simultaneous dual-radionuclide images acquired using IQ-SPECT. This work also demonstrates that ESSE scatter

  10. Initial experience with SPECT imaging of the brain using I-123 p-iodoamphetamine in focal epilepsy

    International Nuclear Information System (INIS)

    LaManna, M.M.; Sussman, N.M.; Harner, R.N.

    1989-01-01

    Nineteen patients with complex partial seizures refractory to medical treatment were examined with routine electroencephalography (EEG), video EEG monitoring, computed tomography or magnetic resonance imaging, neuropsychological tests and interictal single photon emission computed tomography (SPECT) with I-123 iodoamphetamine (INT). In 18 patients, SPECT identified areas of focal reduction in tracer uptake that correlated with the epileptogenic focus identified on the EEG. In addition, SPECT disclosed other areas of neurologic dysfunction as elicited on neuropsychological tests. Thus, IMP SPECT is a useful tool for localizing epileptogenic foci and their associated dynamic deficits

  11. Clinical Utility of SPECT/CT Imaging Post-Radioiodine Therapy: Does It Enhance Patient Management in Thyroid Cancer?

    Science.gov (United States)

    Hassan, Fahim U; Mohan, Hosahalli K

    2015-12-01

    The aim of this study was to evaluate post-therapy iodine-131 single-photon emission computed tomography/computed tomography ((131)I-SPECT/CT) imaging in comparison to conventional planar (131)I whole-body imaging, and to assess its clinical impact on the management of patients. We retrospectively reviewed planar (131)I whole-body and (131)I-SPECT/CT imaging findings in 67 patients who underwent (131)I therapy for thyroid cancer. Two nuclear medicine physicians reviewed the scans independently. The foci of increased tracer uptake were identified in the neck, thorax and elsewhere. Within the neck, the foci of (131)I-increased uptake were graded qualitatively as probable or definite uptake in thyroid remnants and probable or definite uptake in the lymph nodes. Serum thyroglobulin level, histopathology and other imaging findings served as the reference standard. Of the 67 patients, 57 (85%) had radioiodine avid disease and 10 (15%) demonstrated non-radioiodine avid disease. Overall, post-therapy (131)I-SPECT/CT downstaged lymph node staging in 10 patients and upstaged it in 4 patients. This translated into a change of management for 9/57 (16%) patients with radioiodine avid disease. A change of management was observed in 5/10 patients with non-radioiodine avid disease confirmed in the post-(131)I-SPECT/CT study. Additionally, clinically significant findings such as incidental lung cancer, symptomatic pleural effusion and consolidation were also diagnosed in both groups of patients. In patients with thyroid cancer, (131)I-SPECT/CT is a valuable addition to standard post-therapy planar imaging. SPECT/CT also improved diagnostic confidence and provided crucial clinical information leading to change of management for a significant number of these patients.

  12. Sensitivity of technetium-99m-d,1-HMPAO to radiolysis in aqueous solutions

    International Nuclear Information System (INIS)

    Tubergen, K.; Corlija, M.; Volkert, W.A.; Holmes, R.A.

    1991-01-01

    The sensitivity of technetium-99m- (99mTc) d,l-HMPAO to radiolytically induced dissociation in aqueous solutions was investigated. It was found that cobalt-60 (60Co) gamma irradiation of solutions containing 99mTc-d,l-HMPAO with only 1600 cGy reduced the lipophilic chelates' radiochemical purity (RCP) to 50%-60%. The radiolytic sensitivity of 99mTc-meso-HMPAO is significantly lower. The results indicate that radiolytically produced intermediates limit the in vitro stability of 99mTc-d,l-HMPAO

  13. Advances in regional cerebral blood flow measurement and patho-physiological analysis by SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Odano, Ikuo [Niigata Univ. (Japan). School of Medicine

    1994-04-01

    Recently, two kinds of radiopharmaceuticals have been developed to represent the biodistribution of regional blood flow, which are N-isopropyl-p-[[sup 123]I]iodoamphetamine (IMP) and [sup 99m]Tc-hexamethylpropylene-amine-oxime (HMPAO). The charachteristics, clinical usage and imitation of these two radiolabeled agents are discussed. The advantage of [sup 123]I-IMP is that it has high first-pass extraction and long retention in brain tissue, hence it can be used to measure the absolute values of regional cerebral blood flow (rCBF). When the kinetics of [sup 123]I-IMP is assumed to be freely diffusible in the brain, its behavior is considered by 2-compartment model, especially which is assumed by the microsphere model in the early period after the i.v. injection of [sup 123]I-IMP. Comparing the rCBF measured by [sup 123]I-IMP with that by [sup 133]Xe inhalation SPECT method, we have to consider PaCO[sub 2] when both SPECT studies are performed, because PaCO[sub 2] is one of the big factors which make effects on the alteration of rCBF. [sup 123]I-IMP has an interesting character of the redistribution phenomenon which represrent the degree of ischemia in the cerebrovascular diseases. Distribution volume an important datum obtained by the SPECT study with [sup 123]I-IMP, which represent the degree of retention, i.e. binding potential of [sup 123]I-IMP in the brain tissue. I introduced the usage of the distribution volume of [sup 123]I-IMP, which was constructed in the rate constant square method, in the differential diagnosis of Parkinson's disease and progressive supranuclear palsy (PSP). The clinical usage of [sup 99m] Tc-HMPAT was mentioned, the advantage of which is the rapid fixation in the brain tissue and the distribution does not change for long time after the i.v. injection. Hence [sup 99m]Tc-HMPAO is used for the diagnosis of epileptic foci and certain loading tests such as balloon occlusion test, postural test and acetazolamide loading test. (author).

  14. Clinical study of cerebral blood flow in unilateral chronic subdural hematoma measured by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Okuyama, Tohru; Saito, Koji; Fukuyama, Kohichi; Yamamoto, Kouki; Morimoto, Mamoru; Aburano, Tamio

    2000-01-01

    Cerebral blood flow (CBF) measured by 99m Tc-HMPAO SPECT before operation was studied in 60 patients with unilateral chronic subdural hematoma. The regional CBF was measured in 26 regions of the fronto-occipital 10 cortices, putamen, thalamus and cerebellar hemisphere on both sides. Sixty cases with unilateral chronic subdural hematoma were classified into four groups on the basis of clinical symptoms: 17 cases with headache (headache group), 34 cases with hemiparesis (hemiparesis group) and 9 cases with consciousness disturbance or dementia (consciousness disturbance group), and into three groups on the basis of the degree of midline brain shift on MRI: 7 cases of mild shift group, 24 cases of moderate shift group and 29 cases of severe shift group. The average CBF in 60 patients in each region indicated that the regional CBF was reduced in frontal, occipital cortices and cerebellum on the non-hematoma side, and in putamen and thalamus on the hematoma side. In the headache group, the regional CBF reduction on the non-hematoma side was found in only frontal and occipital cortices compared with the corresponding regions on the hematoma side. In the hemiparesis group, the regional CBF was reduced in frontal and occipital cortices on the non-hematoma side and in putamen and thalamus on the hematoma side. The part of CBF reduction in both hemispheres was also noted in the hemiparesis group. In the consciousness disturbance group, the CBF reduction was markedly noted in whole brain. The CBF reductions in frontal and occipital cortices on the non-hematoma side and in putamen, thalamus and cerebellum on the hematoma side was not mutually related with the degree of midline brain shift. We concluded that the disturbance of CBF in chronic subdural hematoma was started from frontal and occipital cortices on the non-hematoma side observed in the headache group, and which was extended to putamen and thalamus on the hematoma side and a part of both hemispheres observed in the

  15. The study of brain dopamine transporter 99Tcm-TRODAT-1 SPECT imaging

    International Nuclear Information System (INIS)

    Yang Jian; Su Min; Liu Xiuqian; Liang Weijuan; Zhao Bin; Xu Zhien

    2006-01-01

    Objective: To investigate the distribution character of 99 Tc m -2β-[N, N'-bis (2-mercaptoethyl) ethylenediamino] methyl, 3β-(4-chlorophenyl) tropane (TRODAT-1) in basal ganglia and the diagnostic value of SPECT imaging in Parkinson' s disease (PD). Methods: 99 Tc m -TRODAT-l SPECT imaging was performed in 30 PD patients and 16 age-matched healthy volunteers. Two semiquantitative analysis methods were used: (1)Striatum(ST)/cerebellum (CB) uptake ratio (ST/CB) was calculated by regions of interest (ROIs) in three transverse and sagittal slice. (2) ROIs were drawn manually on six subregions of both basal ganglia and also CB and occipital region(OC) as reference, and the corresponding uptake ratio of ROI/(OC + CB/2) was calculated. Results: The ST/CB in transverse and sagittal slice for the left and right were 1.55 ± 0.15, 1.58 ± 0.14 and 1.62 ± 0.17, 1.69 ± 0.16 respectively in healthy volunteers. The ST/CB and ROI/(OC + CB/2) in the basal ganglia of PD patients were significantly less than those of healthy volunteers (P 99 Tc m -TRODAT-1 SPECT imaging is an effective method in diagnosis of PD. (authors)

  16. Cerebral control of bladder storage in patients with detrusor overactivity: An activation study using SPECT with NEUROSTAT

    International Nuclear Information System (INIS)

    Yafu, Y.; Li, X.; Li, Y.

    2007-01-01

    Full text: The aim of this study was to identify the brain areas which control the bladder storage in the patients with detrusor overactivity (DO) and those without DO by 99mTc-hexamethylpropylene amine oxime (99mTc-HMPAO) SPECT with Neurological Statistical Image Analysis Software (NEUROSTAT). Methods: SPECT scans were performed on fifteen healthy volunteers (Group I) and twenty-five patients with some storage symptoms of lower urinary tract, among whom nineteen patients were with DO (Group II) and six patients were with normal detrusor function (Group III). All the subjects were male and right-handed. Each subject was scanned twice without movement in a supine position. 444MBq and 555MBq 99mTc- HMPAO were separately injected intravenously under the following two conditions: resting state with empty bladder and urine withholding state with full bladder. The final image during urine withholding was obtained by subtracting the first scan data from the second. NEUROSTAT was adopted to analyze the difference in rCBF between groups in resting state and to analyze the change in rCBF between urine withholding and resting states in each group. The results were displayed on Z-score images at a significance threshold of P < 0.05 with correction for multiple comparisons. Results: No region reached significant threshold in comparison of Group II and Group III in resting state, although Group II and III , as compared with Group I, showed decreases in tracer activity in superior temporal gyrus, medial frontal gyrus, inferior frontal gyrus, anterior cingulate and cingulate gyrus. There were significant increases in tracer activity in bilateral inferior frontal gyri and the right middle temporal gyrus in urine withholding state as compared with resting state in Group III. Among the regions, the right inferior frontal gyrus was distinctly prominent at both Z-score and the extent. In Group II, the regions that were activated significantly in Group III did not reach significant

  17. Kit formulated asialoglycoprotein receptor targeting tracer based on copolymer for liver SPECT imaging.

    Science.gov (United States)

    Liu, Chang; Guo, Zhide; Zhang, Pu; Song, Manli; Zhao, Zuoquan; Wu, Xiaowei; Zhang, Xianzhong

    2014-08-01

    Specific targeting of galactose-carrying molecule to ASGP-R in normal hepatocytes has been demonstrated before. In this study, galactosyl polystyrene was synthesized from controllable ratio of functional monomers and radio-labelled with (99m)Tc by formulated kit for SPECT imaging of hepatic function. p(VLA-co-VNI)(46:54) was synthesized by free-radical copolymerization initiated by AIBN, purified by dialysis, lyophilized to kit with Tricine and TPPTS as co-ligands for (99m)Tc labeling. Radiotracer (99m)Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was prepared and evaluated by in vitro stability, in vivo metabolism, ex vivo biodistribution and microSPECT/CT imaging in normal KM mice. MicroSPECT/CT and microMRI imaging were also performed in C57BL/b6 mice with xenograft hepatic carcinoma for hepatic function evaluation. (99m)Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) was obtained in high radio chemical purity (RCP) (>99%) by using instant kit without further purification and excellent in vitro and in vivo stability. The result of biodistribution showed that liver had high uptake (90.49±10.68 ID%/g) at 30 min after injection and was blocked significantly by cold copolymer. MicroSPECT imaging in normal KM mice at 1h and 4h after injection showed good liver retention and targeting properties. Significant defect of activity was observed in the tumor site which was confirmed by MRI imaging. (99m)Tc-p(VLA-co-VNI)(46:54)(Tricine)(TPPTS) with lower ratio of targeting moiety has no observable effect on the specific binding affinity and liver uptake. This makes it possible to introduce more imaging units for multi-modality imaging. Furthermore, the instant kit preparation of (99m)Tc-labeling provides great potential for the evaluation of hepatocyte function in clinical application. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Automated MicroSPECT/MicroCT Image Analysis of the Mouse Thyroid Gland.

    Science.gov (United States)

    Cheng, Peng; Hollingsworth, Brynn; Scarberry, Daniel; Shen, Daniel H; Powell, Kimerly; Smart, Sean C; Beech, John; Sheng, Xiaochao; Kirschner, Lawrence S; Menq, Chia-Hsiang; Jhiang, Sissy M

    2017-11-01

    The ability of thyroid follicular cells to take up iodine enables the use of radioactive iodine (RAI) for imaging and targeted killing of RAI-avid thyroid cancer following thyroidectomy. To facilitate identifying novel strategies to improve 131 I therapeutic efficacy for patients with RAI refractory disease, it is desired to optimize image acquisition and analysis for preclinical mouse models of thyroid cancer. A customized mouse cradle was designed and used for microSPECT/CT image acquisition at 1 hour (t1) and 24 hours (t24) post injection of 123 I, which mainly reflect RAI influx/efflux equilibrium and RAI retention in the thyroid, respectively. FVB/N mice with normal thyroid glands and TgBRAF V600E mice with thyroid tumors were imaged. In-house CTViewer software was developed to streamline image analysis with new capabilities, along with display of 3D voxel-based 123 I gamma photon intensity in MATLAB. The customized mouse cradle facilitates consistent tissue configuration among image acquisitions such that rigid body registration can be applied to align serial images of the same mouse via the in-house CTViewer software. CTViewer is designed specifically to streamline SPECT/CT image analysis with functions tailored to quantify thyroid radioiodine uptake. Automatic segmentation of thyroid volumes of interest (VOI) from adjacent salivary glands in t1 images is enabled by superimposing the thyroid VOI from the t24 image onto the corresponding aligned t1 image. The extent of heterogeneity in 123 I accumulation within thyroid VOIs can be visualized by 3D display of voxel-based 123 I gamma photon intensity. MicroSPECT/CT image acquisition and analysis for thyroidal RAI uptake is greatly improved by the cradle and the CTViewer software, respectively. Furthermore, the approach of superimposing thyroid VOIs from t24 images to select thyroid VOIs on corresponding aligned t1 images can be applied to studies in which the target tissue has differential radiotracer retention

  19. Determination of Three-Dimensional Left Ventricle Motion to Analyze Ventricular Dyssyncrony in SPECT Images

    DEFF Research Database (Denmark)

    de Sá Rebelo, Marina; Aarre, Ann Kirstine Hummelgaard; Clemmesen, Karen-Louise

    2010-01-01

    A method to compute three-dimension (3D) left ventricle (LV) motion and its color coded visualization scheme for the qualitative analysis in SPECT images is proposed. It is used to investigate some aspects of Cardiac Resynchronization Therapy (CRT). The method was applied to 3D gated-SPECT images...... sets from normal subjects and patients with severe Idiopathic Heart Failure, before and after CRT. Color coded visualization maps representing the LV regional motion showed significant difference between patients and normal subjects. Moreover, they indicated a difference between the two groups...

  20. TH-C-17A-06: A Hardware Implementation and Evaluation of Robotic SPECT: Toward Molecular Imaging Onboard Radiation Therapy Machines

    International Nuclear Information System (INIS)

    Yan, S; Touch, M; Bowsher, J; Yin, F; Cheng, L

    2014-01-01

    Purpose: To construct a robotic SPECT system and demonstrate its capability to image a thorax phantom on a radiation therapy flat-top couch. The system has potential for on-board functional and molecular imaging in radiation therapy. Methods: A robotic SPECT imaging system was developed utilizing a Digirad 2020tc detector and a KUKA KR150-L110 robot. An imaging study was performed with the PET CT Phantom, which includes 5 spheres: 10, 13, 17, 22 and 28 mm in diameter. Sphere-tobackground concentration ratio was 6:1 of Tc99m. The phantom was placed on a flat-top couch. SPECT projections were acquired with a parallel-hole collimator and a single pinhole collimator. The robotic system navigated the detector tracing the flat-top table to maintain the closest possible proximity to the phantom. For image reconstruction, detector trajectories were described by six parameters: radius-of-rotation, x and z detector shifts, and detector rotation θ, tilt ϕ and twist γ. These six parameters were obtained from the robotic system by calibrating the robot base and tool coordinates. Results: The robotic SPECT system was able to maneuver parallel-hole and pinhole collimated SPECT detectors in close proximity to the phantom, minimizing impact of the flat-top couch on detector-to-COR (center-ofrotation) distance. In acquisitions with background at 1/6th sphere activity concentration, photopeak contamination was heavy, yet the 17, 22, and 28 mm diameter spheres were readily observed with the parallel hole imaging, and the single, targeted sphere (28 mm diameter) was readily observed in the pinhole region-of-interest (ROI) imaging. Conclusion: Onboard SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frame could be an effective means to estimate detector pose for use in SPECT image reconstruction. PHS/NIH/NCI grant R21-CA156390-01A1

  1. The effect of acquisition interval and spatial resolution on dynamic cardiac imaging with a stationary SPECT camera

    International Nuclear Information System (INIS)

    Roberts, J; Maddula, R; Clackdoyle, R; DiBella, E; Fu, Z

    2007-01-01

    The current SPECT scanning paradigm that acquires images by slow rotation of multiple detectors in body-contoured orbits around the patient is not suited to the rapid collection of tomographically complete data. During rapid image acquisition, mechanical and patient safety constraints limit the detector orbit to circular paths at increased distances from the patient, resulting in decreased spatial resolution. We consider a novel dynamic rotating slant-hole (DyRoSH) SPECT camera that can collect full tomographic data every 2 s, employing three stationary detectors mounted with slant-hole collimators that rotate at 30 rpm. Because the detectors are stationary, they can be placed much closer to the patient than is possible with conventional SPECT systems. We propose that the decoupling of the detector position from the mechanics of rapid image acquisition offers an additional degree of freedom which can be used to improve accuracy in measured kinetic parameter estimates. With simulations and list-mode reconstructions, we consider the effects of different acquisition intervals on dynamic cardiac imaging, comparing a conventional three detector SPECT system with the proposed DyRoSH SPECT system. Kinetic parameters of a two-compartment model of myocardial perfusion for technetium-99m-teboroxime were estimated. When compared to a conventional SPECT scanner for the same acquisition periods, the proposed DyRoSH system shows equivalent or reduced bias or standard deviation values for the kinetic parameter estimates. The DyRoSH camera with a 2 s acquisition period does not show any improvement compared to a DyRoSH camera with a 10 s acquisition period

  2. The effect of acquisition interval and spatial resolution on dynamic cardiac imaging with a stationary SPECT camera

    Science.gov (United States)

    Roberts, J.; Maddula, R.; Clackdoyle, R.; Di Bella, E.; Fu, Z.

    2007-08-01

    The current SPECT scanning paradigm that acquires images by slow rotation of multiple detectors in body-contoured orbits around the patient is not suited to the rapid collection of tomographically complete data. During rapid image acquisition, mechanical and patient safety constraints limit the detector orbit to circular paths at increased distances from the patient, resulting in decreased spatial resolution. We consider a novel dynamic rotating slant-hole (DyRoSH) SPECT camera that can collect full tomographic data every 2 s, employing three stationary detectors mounted with slant-hole collimators that rotate at 30 rpm. Because the detectors are stationary, they can be placed much closer to the patient than is possible with conventional SPECT systems. We propose that the decoupling of the detector position from the mechanics of rapid image acquisition offers an additional degree of freedom which can be used to improve accuracy in measured kinetic parameter estimates. With simulations and list-mode reconstructions, we consider the effects of different acquisition intervals on dynamic cardiac imaging, comparing a conventional three detector SPECT system with the proposed DyRoSH SPECT system. Kinetic parameters of a two-compartment model of myocardial perfusion for technetium-99m-teboroxime were estimated. When compared to a conventional SPECT scanner for the same acquisition periods, the proposed DyRoSH system shows equivalent or reduced bias or standard deviation values for the kinetic parameter estimates. The DyRoSH camera with a 2 s acquisition period does not show any improvement compared to a DyRoSH camera with a 10 s acquisition period.

  3. Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

    Science.gov (United States)

    Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C

    2015-04-13

    Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.

  4. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  5. Ocular melanoma: Detection using iodine-123-iodoamphetamine and SPECT imaging

    International Nuclear Information System (INIS)

    Dewey, S.H.; Leonard, J.C.

    1990-01-01

    Uptake of iodine-123-iodoamphetamine has been demonstrated in malignant melanoma using planar imaging techniques and has been used to detect an ocular melanoma at 12 hr postinjection. Using SPECT technique, an ocular melanoma is identified in a 64-yr-old male at 1 hr postinjection

  6. Use of images of ictal-inter-ictal SPECT subtraction superimposed on MRI in pharmaco-resistant partial epilepsies in infants

    International Nuclear Information System (INIS)

    Vera, P.; Kaminska, A.; Cieuta, C.; Mangin, F.; Frouin, V.; Dulac, O.; Chiron, C.

    1997-01-01

    To study the significance of ictal SPECT in the pre-surgical examination of infant epilepsies we have explored 16 infants aged 3 months to 18 years presenting partial pharmaco-resistant epilepsy. All of them have had an ictal SPECT under EEG - video recording than, two days after, an inter-ictal SPECT coupled to a 3D cerebral MRI. The perfusion tracer, the 99m Tc - ECD, was injected in average at 15 seconds after the outset of crisis. The image processing implied a matching of the two SPECT examinations by a 3D rigid superposition method, a normalization and than a inter-ictal-ictal image subtraction. Finally, the subtraction was matched and superimposed on the MRI. The SPECT subtraction image showed one or several centres of ictal hyper-output in 15 patients, while the separated visual ictal and inter-ictal images were contributory in 8 cases only. The 16. infant presented very short crises (<10 sec). In the cases when the outset point of crises could be established clinically (12 cases) and/or on EEG (8 cases) a hyper-output of concordant localization was recorded. In 5 infants who have had an electrocorticography, a concordance was obtained in all the cases except in an infant having very short crises the subtraction image did not show hyper-output. These preliminary results show that the ictal - inter-ictal SPECT subtraction images, adjusted on MRI, appears to be reliable in detecting the outset point of crises in infants and at the same time useful in guiding the positioning of intra-cranial electrodes prior to surgery intervention

  7. Validation of a cartridge method for the quality control determination of 99Tcm-HMPAO

    International Nuclear Information System (INIS)

    Pandos, G.; Penglis, S.; Tsopelas, C.; Royal Adelaide Hospital, Adelaide, SA

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of ±-HMPAO requires the use of three solvent types on two different stationary phases, and is time-consuming (∼ 15 min) in consideration of the short shelf-life (30 min). An impetus to develop a rapid quality control procedure for this product has led to the use of a single strip Whatman 17 chromatography system using ethyl acetate as the developing solvent. This popular Whatman paper system was previously validates against the manufacturer's method. We have developed a new method to successfully determine the % RCP of ±-HMPAO, which employs a disposable, inexpensive and reusable Amprep C-18 cartridge with normal saline as a non-organic mobile phase. The Whatman paper system separates the primary lipophilic 99 Tc m -HMPAO complex from 99 Tc m O-2, 99 Tc m O 4 and secondary 99 Tc m -HMPAO complex at the origin. By comparison, the lipophilic portion was retained on the cartridge and the hydrophilic impurities were found in saline eluent with the cartridge method. Whatman 17 paper system results showed 95.1 ± I.7% 99 Tc m -HMPAO after 5 min and the cartridge method gave 95.5 ± 1.5% 99 Tc m -HMPAO (n = 8) after 3 min. The % 99 Tc m O 2 levels in 99 Tc m -HMPAO were insignificant. When a failed kit was assessed for RCP at 2.5 h post-reconstitution, the Whatman paper system and the cartridge method correlated well, resulting in 63.1 ± 2.7% and 62.9±2.1% 99 Tc m -HMPAO (n=3) respectively. Although the cartridge method may slightly overestimate the % RCP of 99 Tc m -HMPAO, it was found to be simple, rapid and reliable for the quality control analysis of routine 99 Tc m -HMPAO preparations

  8. Evaluation of the parameters of SPECT images for yttrium-90 in radiosinoviorthesis; Avaliação dos parâmetros de aquisição de imagens SPECT para ítrio-90 em radiosinoviortese

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, B.C. de; Sáa, L.V. de, E-mail: bruce.de.toledo@gmail.com [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Física Médica; Ramos, S.M.; Coelho, F.A.; Thomas, S.; Souza, S.A. de; Pinheiro, M.A. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Hospital Universitário Clementino Fraga Filho

    2017-07-01

    Introduction: the evaluation of the distribution of radioactive material in the articulation by SPECT images after radiosinoviorthesis (RSO) can guarantee the efficacy of this therapy. However, Bremsstrahlung image quality has major limitations, necessitating studies on SPECT image acquisition parameters and yttrium-90 image reconstruction methods. Methods: SPECT images were obtained from an acrylic simulator containing four cylindrical inserts to simulate capturing lesions. The images were obtained with collimators of high, medium and low (HEGP, MEGP and LEHR) energy; 130 keV power window, 70% width and 64 x 64 matrix. The reconstruction methods used were: FBP and OSEM with different filters. Results: 45 results found. The images obtained with the MEGP and HEGP collimators presented better results than those obtained with the LEHR collimator. The OSEM reconstructions were superior when the MEGP and HEGP collimators were used. Conclusions: The acquisition of yttrium-90 SPECT images with MEGP collimators showed higher sensitivity, whereas those obtained with HEPG collimators presented lower noise. The image reconstruction methods have relevant importance in the image quality, showing a significant difference between the FBP and OSEM reconstructions and between the filters used.

  9. Evaluation of Tourette's syndrome by 99Tcm-TRODAT-1 SPECT imaging

    International Nuclear Information System (INIS)

    Dong Feng; Liu Hong; Meng Zhaowei; Tan Jian; Zhang Benshu

    2011-01-01

    Objective: To observe dopamine transporter (DAT) binding capacity using 99 Tc m -TRODAT-1 in drug-naive patients with Tourette's syndrome (TS) on SPECT imaging, and explore possible correlations between 99 Tc m -TRODAT-1 uptake ratio and TS patient's age, disease duration, and tic severity. Methods: Eighteen drug-naive TS patients, male 14, female 4, as well as 8 age- and gender-matched healthy subjects were recruited. Brain SPECT imaging was performed 2. 5 h after intravenous injection of 11.1 - 14.8 MBq/kg 99 Tc m -TRODAT-1. ROI was drawn on the striatum including its sub-regions of caudate and putamen, with cerebellum as the background. Striatum/cerebellum ratio was calculated. Comparisons of the ratios between TS patients and controls were carried out by independent-sample t-test. Pearson correlation analysis was performed between DAT uptake ratios of striatum and patients' age, disease duration, tic severity. Results: Compared with the control, higher symmetrically striatum uptake of 99 Tc m -TRODAT-1 in TS patients was observed (2.17±0.23 vs 1.87±0.24, t=2.957, P 0.05)and tic severity(r=0.345, P>0.05) scores were not significantly correlated with specific uptake ratios measured in the striatum. But there was significant negative correlation between disease duration and the specific uptake ratios (r=-0.483, P 99 Tc m -TRODAT-1 SPECT imaging may play an adjuvant role for initial evaluation of untreated TS. (authors)

  10. Prognostic value of gated 201Tl myocardial perfusion SPECT imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Li Zicheng; Chen Xiaoming; Xu Hao

    2006-01-01

    Objective: To study the prognostic value of gated 201 Tl myocardial perfusion SPECT imaging in patients with coronary artery disease and assessment of therapy strategy for the individual patient. Methods: Eighty-four patients underwent rest and exercise stress 201 Tl gated myocardial perfusion SPECT imaging and were followed up for (32.92 ± 16.77) months. Images were studied using 17 segments and 1 to 4 scoring. Global summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS=SSS-SRS) were also calculated. Post-stress and rest ejection fraction (EF) were automatically measured. Results: Nine cardiac events occurred (3.90% per year). SSS, SDS, SRS and EF were the independent predictors of cardiac events (P 201 Tl myocardial perfusion SPECT imaging can provide prognostic assessment for the patients with coronary artery disease and guide in selection of therapeutic strategy. Among all of the indices SSS is the best predictors of cardiac events. (authors)

  11. SPECT imaging of D2 dopamine receptors and endogenous dopamine release in mice

    International Nuclear Information System (INIS)

    Jongen, Cynthia; Bruin, Kora de; Booij, Jan; Beekman, Freek

    2008-01-01

    The dopamine D 2 receptor (D2R) is important in the mediation of addiction. [ 123 I]iodobenzamide (IBZM), a SPECT ligand for the D2R, has been used for in vivo studies of D2R availability in humans, monkeys, and rats. Although mouse models are important in the study of addiction, [ 123 I]IBZM has not been used in mice SPECT studies. This study evaluates the use of [ 123 I]IBZM for measuring D2R availability in mice. Pharmacokinetics of [ 123 I]IBZM in mice were studied with pinhole SPECT imaging after intravenous (i.v.) injection of [ 123 I]IBZM (20, 40, and 70 MBq). In addition, the ability to measure the release of endogenous dopamine after amphetamine administration with [ 123 I]IBZM SPECT was investigated. Thirdly, i.v. administration, the standard route of administration, and intraperitoneal (i.p.) administration of [ 123 I]IBZM were compared. Specific binding of [ 123 I]IBZM within the mouse striatum could be clearly visualized with SPECT. Peak specific striatal binding ratios were reached around 90 min post-injection. After amphetamine administration, the specific binding ratios of [ 123 I]IBZM decreased significantly (-27.2%; n=6; p=0.046). Intravenous administration of [ 123 I]IBZM led to significantly higher specific binding than i.p. administration of the same dose. However, we found that i.v. administration of a dose of 70 MBq [ 123 I]IBZM might result in acute ethanol intoxication because ethanol is used as a preparative aid for the routine production of [ 123 I]IBZM. Imaging of D2R availability and endogenous dopamine release in mice is feasible using [ 123 I]IBZM single pinhole SPECT. Using commercially produced [ 123 I]IBZM, a dose of 40 MBq injected i.v. can be recommended. (orig.)

  12. A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in (131)I SPECT.

    Science.gov (United States)

    Dewaraja, Yuni K; Ljungberg, Michael; Majumdar, Amitava; Bose, Abhijit; Koral, Kenneth F

    2002-02-01

    This paper reports the implementation of the SIMIND Monte Carlo code on an IBM SP2 distributed memory parallel computer. Basic aspects of running Monte Carlo particle transport calculations on parallel architectures are described. Our parallelization is based on equally partitioning photons among the processors and uses the Message Passing Interface (MPI) library for interprocessor communication and the Scalable Parallel Random Number Generator (SPRNG) to generate uncorrelated random number streams. These parallelization techniques are also applicable to other distributed memory architectures. A linear increase in computing speed with the number of processors is demonstrated for up to 32 processors. This speed-up is especially significant in Single Photon Emission Computed Tomography (SPECT) simulations involving higher energy photon emitters, where explicit modeling of the phantom and collimator is required. For (131)I, the accuracy of the parallel code is demonstrated by comparing simulated and experimental SPECT images from a heart/thorax phantom. Clinically realistic SPECT simulations using the voxel-man phantom are carried out to assess scatter and attenuation correction.

  13. Image viewing station for MR and SPECT : using personal computer

    International Nuclear Information System (INIS)

    Yim, Byung Il; Jeong, Eun Kee; Suh, Jin Suck; Kim, Myeong Joon

    1996-01-01

    Macro language was programmed to analyze and process on Macintosh personal computers, GEMR images digitally transferred from the MR main computer, with special interest in the interpretation of information such as patients data and imaging parameters under each image header. By this method, raw data(files) of certain patients may be digitally stored on a hard disk or CD ROM, and the quantitative analysis, interpretation and display is possible. Patients and images were randomly selected 4.X MR images were transferred through FTP using the ethernet network. 5.X and SPECT images were transferred using floppy diskettes. To process transferred images, an freely distributed software for Macintosh namely NIH Image, with its macro language, was used to import images and translate header information. To identify necessary information, a separate window named I nfo=txt , was made for each image series. MacLC, Centris650, and PowerMac6100/CD, 7100/CD, 8100/CD models with 256 color and RAM over 8Mbyte were used. Different versions of MR images and SPECT images were displayed simultaneously and a separate window named 'info-txt' was used to show all necessary information(name of the patient, unit number, date, TR, TE, FOV etc.). Additional information(diagnosis, pathologic report etc.) was stored in another text box in 'info-txt'. The size of the file for each image plane was about 149Kbytes and the images were stored in a step-like file folders. 4.X and 5.X GE Signa 1.5T images were successfully processed with Macintosh computer and NIH Image. This result may be applied to many fields and there is hope of a broader area of application with the linkage of NIH Image and a database program

  14. Simultaneous reconstruction and segmentation for dynamic SPECT imaging

    International Nuclear Information System (INIS)

    Burger, Martin; Rossmanith, Carolin; Zhang, Xiaoqun

    2016-01-01

    This work deals with the reconstruction of dynamic images that incorporate characteristic dynamics in certain subregions, as arising for the kinetics of many tracers in emission tomography (SPECT, PET). We make use of a basis function approach for the unknown tracer concentration by assuming that the region of interest can be divided into subregions with spatially constant concentration curves. Applying a regularised variational framework reminiscent of the Chan-Vese model for image segmentation we simultaneously reconstruct both the labelling functions of the subregions as well as the subconcentrations within each region. Our particular focus is on applications in SPECT with the Poisson noise model, resulting in a Kullback–Leibler data fidelity in the variational approach. We present a detailed analysis of the proposed variational model and prove existence of minimisers as well as error estimates. The latter apply to a more general class of problems and generalise existing results in literature since we deal with a nonlinear forward operator and a nonquadratic data fidelity. A computational algorithm based on alternating minimisation and splitting techniques is developed for the solution of the problem and tested on appropriately designed synthetic data sets. For those we compare the results to those of standard EM reconstructions and investigate the effects of Poisson noise in the data. (paper)

  15. Response analysis for an approximate 3-D image reconstruction in cone-beam SPECT

    International Nuclear Information System (INIS)

    Murayama, Hideo; Nohara, Norimasa

    1991-01-01

    Cone-beam single photon emission computed tomography (SPECT) offers the potential for a large increase in sensitivity as compared with parallel hole or fan-beam collimation. Three-dimensional image reconstruction was approximately accomplished by backprojecting filtered projections using a two-dimensional fan-beam algorithm. The cone-beam projection data were formed from mathematical phantoms as analytically derived line integrals of the density. In order to reduce the processing time, the filtered projections were backprojected into each plane parallel to the circle on which the focal point moved. Discrepancy of source position and degradation of resolution were investigated by computer simulation in three-dimensional image space. The results obtained suggest that, the nearer to the central plane or the axis of rotation, the less image degradation is performed. By introducing a parameter of angular difference between the focal point and a fixed point in the image space during rotation, degradation of the reconstructed image can be estimated for any cone-beam SPECT system. (author)

  16. Contribution of the cerebral SPECT in the field of evaluation of the hemodynamic cerebral vascular accident risk in the Limb shaking syndrome; Apport de la TEMP cerebrale dans le cadre de l'evaluation du risque d'AVC hemodynamique dans le Limb Shaking Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lauer, V.; Wolff, V.; Marescaux, C. [CHU de Strasbourg, Unite neurovasculaire, service de neurologie, 67 (France); Namer, I.J. [CHU de Strasbourg, service de biophysique et medecine nucleaire, 67 -Strasbourg (France)

    2010-07-01

    The limb shaking syndrome (L.S.S.) is characterized by uncontrollable shaking of members that are caused by a passage in the upright or by an hyper extension of the neck and occur in a patient with internal carotid stenosis. To investigate the pathophysiology of L.S.S. we used brain SPECT (SPECT-E.C.D. or H.M.P.A.O.) to measure cerebral perfusion in the supine position and standing in three patients. (N.C.)

  17. Analysis of CT and PET/SPECT images for dosimetry calculation

    International Nuclear Information System (INIS)

    Massicano, Felipe; Massicano, Adriana V.F.; Silva, Natanael Gomes da; Cintra, Felipe Belonsi; Yoriyaz, Helio; Carvalho, Rodrigo Mueller de

    2009-01-01

    Computer images are routinely used in diagnostic centers and hospitals. In particular in the field of Nuclear Medicine they help in the diagnosis and planning therapy against cancer. In the case of the planning therapy the quantifying the distribution of dose in patients is very important, because it provides an estimate of the dose in the tumor and healthy tissues, allowing a greater understanding on the response and toxicity caused by this dose. The aim of this study is to analyze both kinds of images: CT and PET/SPECT and their potential utilization for dosimetry calculation. PET or SPECT images were analyzed using a Gamma Camera, brand Medis, model Nuclide-TH/22 through image acquisition of scanned phantoms containing a known activity inside their volume so that a relationship between the number of counts for each voxel in the image and the real activity will be constructed. The heterogeneous organism patient's is specified from the computed tomography (CT) through number of Hounsfield. However, there is not a simple correlation to convert Hounsfield numbers into material tissues, therefore, in this work we developed a software in Java to convert Hounsfield numbers in mass density. Moreover, the software provides a map of tissues and a text file containing the elemental weights to be used by the Monte Carlo transport code MCNP5 to perform dose calculations. (author)

  18. Multi-pinhole collimator design for small-object imaging with SiliSPECT: a high-resolution SPECT

    International Nuclear Information System (INIS)

    Shokouhi, S; Peterson, T E; Metzler, S D; Wilson, D W

    2009-01-01

    We have designed a multi-pinhole collimator for a dual-headed, stationary SPECT system that incorporates high-resolution silicon double-sided strip detectors. The compact camera design of our system enables imaging at source-collimator distances between 20 and 30 mm. Our analytical calculations show that using knife-edge pinholes with small-opening angles or cylindrically shaped pinholes in a focused, multi-pinhole configuration in combination with this camera geometry can generate narrow sensitivity profiles across the field of view that can be useful for imaging small objects at high sensitivity and resolution. The current prototype system uses two collimators each containing 127 cylindrically shaped pinholes that are focused toward a target volume. Our goal is imaging objects such as a mouse brain, which could find potential applications in molecular imaging.

  19. Software-based hybrid perfusion SPECT/CT provides diagnostic accuracy when other pulmonary embolism imaging is indeterminate

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Nishant; Xie, Karen; Mar, Winnie; Anderson, Thomas M.; Carney, Benjamin; Mehta, Nikhil; Machado, Roberto; Blend, Michael J.; Lu, Yang [University of Illinois Hospital and Health Sciences System, Chicago (Korea, Republic of)

    2015-12-15

    To investigate the diagnostic performance of perfusion single-photon emission computed tomography/computed tomography (Q-SPECT/CT) in patients suspected to have pulmonary embolism (PE) but with indeterminate computed tomographic pulmonary angiography (CTPA) or planar ventilation/perfusion (V/Q) scans. This retrospective study included two groups of patients. Group I consisted of 49 patients with nondiagnostic CTPA. These 49 patients underwent subsequent V/Q scans. Further Q-SPECTs were obtained in patients with indeterminate planar images and fused with existing CTPA. Group II consisted of 182 non-CTPA patients with indeterminate V/Q scans. These 182 patients underwent further Q-SPECT and separate noncontrast low-dose CT chest. Fusion Q-SPECT/CT scans were obtained through FDA-approved software and interpreted according to published criteria as positive, negative, or indeterminate for PE. Upon retrospective analyses, the final diagnosis was made using composite reference standards including all available clinical and imaging information for at least 6-month follow-up. In group I patients, 1 was positive, 24 were negative, and another 24 (49 %, 24/49) were indeterminate. In the subsequent 24 Q-SPECT/CTPAs, 4 were positive, 19 were negative, and 1 was indeterminate (4.2 %, 1/24). In group II patients, 9 (4.9 %, 9/182) were indeterminate, 33 were positive, and 140 were negative. The combined nondiagnostic rate for Q-SPECT/CT was only 4.9 % (10/206). There was six false-negative and one false-positive Q-SPECT/CT examinations. The sensitivity, specificity, and positive and negative predictive value of Q-SPECT/CT were 85.7 % (36/42), 99.4 % (153/154), 97.3 % (36/37) and 96.2 % (153/159), respectively. Q-SPECT/CT improves the diagnostic rate with promising accuracy in diagnosing PE that yields a satisfactory clinical verdict, especially when the CTPA and planar V/Q scan are indeterminate.

  20. Study on effects of an atypical antipsychotic, risperidone on regional cerebral blood flow with 99mTc-HMPAO SPECT in drug-naive and unmedicated schizophrenic patients

    International Nuclear Information System (INIS)

    Koiwa, Daisuke

    2003-01-01

    To examine the underlying mechanisms of intracerebral or clinical actions of the atypical antipsychotic, risperidone (RIS), the effects of RIS on absolute regional cerebral blood flows (rCBFs) measured with 99mTc-HMPAO SPECT and correlations between the rCBFs and psychotic symptoms assessed with positive and negative syndrome scale (PANSS) were investigated in 10 drug-naive and unmedicated schizophrenic patients with acute hallucinatory and delusional state. Both the SPECT and PANSS were repeated before and after oral 2-week administration of RIS 3 mg/day in all of the 10 patients and after subsequent 2-week administration of RIS 4-6 mg/day in half of the patients. The rCBF values were significantly decreased in the left precentral gyrus alone after the low dose of RIS 3 mg/day in comparison with before the RIS dose. The rCBF values were significantly decreased in the right cingulate, postcentral, inferior parietal gyri and the left inferior temporal gyrus after the high dose of RIS 4-6 mg/day in comparison with before the low dose of RIS 3 mg/day. The psychiatric assessment with PANSS showed an improvement of positive and negative symptoms after the low RIS dose and still more after the high RIS dose. Statistical analyses on relationships between the rCBF values and PANSS scores before and after the low RIS dose showed a positive correlation between the rCBF values in the right middle temporal gyrus and hallucinations (mainly auditory hallucination). These results suggest that chronic RIS administration dose-dependently produces a decrease of rCBF in the cerebral cortex in the manner that the low dose decreases rCBF in a few restricted cortical regions, while the high dose induces the rCBF reduction in more widespread cortical regions. The RIS-induced rCBF decrease in the cerebral cortex is considered to be attributable to a secondary inactivation in the cerebral cortex due to D 2 dopamine receptor blockade of RIS in the striatum through the cortico