WorldWideScience

Sample records for hm ii lvad

  1. Oxygenator in short-term LVAD circuit: a rescue in post-LVAD pulmonary complications.

    Science.gov (United States)

    Mohite, Prashant N; Patil, Nikhil P; Popov, Aron-Frederik; Bahrami, Toufan; Simon, Andre R

    2016-10-01

    Pulmonary complications after left ventricular assist device (LVAD) implantation, though infrequent, can be potentially catastrophic. A 62-year-old female with cardiogenic shock, supported on short-term LVAD, developed pulmonary oedema. An oxygenator was introduced into the LVAD circuit, which improved the gas exchange and, eventually, after weaning off the oxygenator, the patient received long-term LVAD. The introduction of an oxygenator into the short-term LAVD circuit is a lifesaving manoeuvre in such a situation. It offers freedom of introducing and removing the oxygenator into the LVAD circuit without opening the chest and competing for LVAD flow. © The Author(s) 2016.

  2. Myocardial changes in patients with end-stage heart failure during continuous flow left ventricular assist device support

    NARCIS (Netherlands)

    Lok, S.I.

    2013-01-01

    With respect to the clinical outcome, cf-LVADs provide sufficient ventricular unloading and circulatory support. The post-operative mortality and morbidity in our centre are comparable with other recent experiences with this device. Based on these data, Heart Mate II (HM II) LVAD therapy can be

  3. Numerical Analysis of Blood Damage Potential of the HeartMate II and HeartWare HVAD Rotary Blood Pumps.

    Science.gov (United States)

    Thamsen, Bente; Blümel, Bastian; Schaller, Jens; Paschereit, Christian O; Affeld, Klaus; Goubergrits, Leonid; Kertzscher, Ulrich

    2015-08-01

    Implantable left ventricular assist devices (LVADs) became the therapy of choice in treating end-stage heart failure. Although survival improved substantially and is similar in currently clinically implanted LVADs HeartMate II (HM II) and HeartWare HVAD, complications related to blood trauma are frequently observed. The aim of this study was to compare these two pumps regarding their potential blood trauma employing computational fluid dynamics. High-resolution structured grids were generated for the pumps. Newtonian flow was calculated, solving Reynolds-averaged Navier-Stokes equations with a sliding mesh approach and a k-ω shear stress transport turbulence model for the operating point of 4.5 L/min and 80 mm Hg. The pumps were compared in terms of volumes subjected to certain viscous shear stress thresholds, below which no trauma was assumed (von Willebrand factor cleavage: 9 Pa, platelet activation: 50 Pa, and hemolysis: 150 Pa), and associated residence times. Additionally, a hemolysis index was calculated based on a Eulerian transport approach. Twenty-two percent of larger volumes above 9 Pa were observed in the HVAD; above 50 Pa and 150 Pa the differences between the two pumps were marginal. Residence times were higher in the HVAD for all thresholds. The hemolysis index was almost equal for the HM II and HVAD. Besides the gap regions in both pumps, the inlet regions of the rotor and diffuser blades have a high hemolysis production in the HM II, whereas in the HVAD, the volute tongue is an additional site for hemolysis production. Thus, in this study, the comparison of the HM II and the HVAD using numerical methods indicated an overall similar tendency to blood trauma in both pumps. However, influences of turbulent shear stresses were not considered and effects of the pivot bearing in the HM II were not taken into account. Further in vitro investigations are required. Copyright © 2015 International Center for Artificial Organs and Transplantation and

  4. LVAD pannus complicating destination therapy

    Directory of Open Access Journals (Sweden)

    Maya Ignaszewski

    2017-11-01

    Full Text Available Despite advances in technology, ventricular assist devices still experience a number of complications limiting their long-term use. We present a 73-year-old woman implanted with a left ventricular assist device (LVAD five years prior due to end-stage dilated cardiomyopathy, who died several weeks after admission to the hospital. Post-mortem examination revealed a large obstructing pannus in the LVAD inflow. As a result of increased LVAD use, complications such as infection, device thrombosis and pannus must be promptly recognized and managed appropriately to ensure the greatest chance of patient survival.

  5. Effects of Percutaneous LVAD Support on Right Ventricular Load and Adaptation.

    Science.gov (United States)

    Yourshaw, Jeffrey P; Mishra, Prabodh; Armstrong, M Christopher; Ramu, Bhavadharini; Craig, Michael L; Van Bakel, Adrian B; Steinberg, Daniel H; DiSalvo, Thomas G; Tedford, Ryan J; Houston, Brian A

    2018-04-30

    Both operative and hemodynamic mechanisms have been implicated in right heart failure (RHF) following surgical left ventricular assist device (LVAD) implantation. We investigated the effects of percutaneous LVAD (pLVAD; Impella®, Abiomed) support on right ventricular (RV) load and adaptation. We reviewed all patients receiving a pLVAD for cardiogenic shock at our institution between July 2014 and April 2017, including only those with pre- and post-pLVAD invasive hemodynamic measurements. Hemodynamic data was recorded immediately prior to pLVAD implantation and up to 96 h post-implantation. Twenty-five patients were included. Cardiac output increased progressively during pLVAD support. PAWP improved early post-pLVAD but did not further improve during continued support. Markers of RV adaptation (right ventricular stroke work index, right atrial pressure (RAP), and RAP to pulmonary artery wedge pressure ratio (RAP:PAWP)) were unchanged acutely implant but progressively improved during continued pLVAD support. Total RV load (pulmonary effective arterial elastance; E A ) and resistive RV load (pulmonary vascular resistance; PVR) both declined progressively. The relationship between RV load and RV adaptation (E A /RAP and E A /RAP:PAWP) was constant throughout. Median vasoactive-inotrope score declined after pLVAD placement and continued to decline throughout support. Percutaneous LVAD support in patients with cardiogenic shock did not acutely worsen RV adaptation, in contrast to previously described hemodynamic effects of surgically implanted durable LVADs. Further, RV load progressively declined during support, and the noted RV adaptation improvement was load-dependent as depicted by constant E A /RA and E A /RAP:PAWP relationships. These findings further implicate the operative changes associated with surgical LVAD implantation in early RHF following durable LVAD.

  6. Electric smog: telemetry interference between ICD and LVAD.

    Science.gov (United States)

    Duncker, David; König, Thorben; Müller-Leisse, Johanna; Michalski, Roman; Oswald, Hanno; Schmitto, Jan D; Bauersachs, Johann; Veltmann, Christian

    2017-09-01

    Electromagnetic interferences between implantable cardioverter/defibrillators (ICD) and left ventricular assist devices (LVAD) impacting telemetry have been described in previous generations of ICD as well as LVAD, but have been predominantly overcome in current ICD generations. After introduction of a new fully magnetically levitated centrifugal continuous-flow circulatory pump, we report a case of tenacious telemetry interference between the HeartMate 3 LVAD and an ICD after battery exchange to an Iforia 5. Initialization of the initial telemetry handshake was only possible using several specific maneuvers simultaneously. In order to exclude device-device interference, we suggest to place the ICD above the LVAD before implantation and to test for possible telemetry interferences.

  7. Application of CAD/CFD/RP-technologies for development of LVAD systems

    Directory of Open Access Journals (Sweden)

    Morozov Valentin

    2016-01-01

    Full Text Available The important problem of new Left Ventricle Assist Device (LVAD systems development is to determine their hemodynamic and functional characteristics and reduce the design time. An effective method for achieving this is the use of approaches based on the application of CAD/CFD/PR-technologies. Methods of computer modelling were applied to determine the geometrical parameters of the blood pump, and methods of finite element analysis were used for the optimization of hemodynamic parameters of the LVAD system. The geometrical modelling was carried out in the Pro/Engineer WF5. The CAE-system Ansys was used to analyze the blood flow in the chamber of the pump. The motion of the flexible walls was simulated by normal flow through rigid walls. At the final stage some models were prepared for prototyping. The critical parameters of hemodynamic gave the possibility to optimize the shape of the blood pump. The LVAD system and its components were made using various RP-technologies. The hydraulic tests for the performance investigation and the analysis of implantability for implantable systems were carried out for manufactured prototypes of LVAD systems. The manufactured components of the LVAD system are completely operability and give the possibility to estimate the critical hemodynamic and functional parameters of the LVAD system.

  8. When LVAD Patients Die: The Caregiver's Mourning.

    Science.gov (United States)

    Rossi Ferrario, Silvia; Omarini, Pierangela; Cerutti, Paola; Balestroni, Giangluigi; Omarini, Giovanna; Pistono, Massimo

    2016-05-01

    Left ventricular assist devices (LVADs) have progressively evolved, particularly in the last 10 years, to serve patients affected by severe heart failure as a bridge to transplant or destination therapy. The survival rate and quality of life of pre- and postimplant patients, as well as caregivers' perceptions and distress, are under investigation by the scientific community. But what caregivers think and feel after the loss of their loved one has not so far been examined. We contacted 16 principal caregivers of deceased LVAD patients by telephone. They were asked to evaluate their experience with LVADs and were administered a specific questionnaire about their mourning, the Caregiver Mourning Questionnaire (CMQ), to evaluate their perceptions of the physical, emotional, and social support-related problems that they had experienced during the previous 3 months. Positive aspects reported by the caregivers were the patient's overall subjective well-being and increased survival. Negative aspects were the difficulty to manage infections and the driveline, and the incomplete autonomy of the patient. Half of the caregivers reported not being preadvised about many of the problems they would face. The CMQ revealed that numerous caregivers had health problems, difficulty in sleeping, eating disorders, lack of energy, and loneliness. Use of psychotropic drugs and regrets about how they assisted their loved one also emerged. In conclusion, caregivers of LVAD patients may experience complicated mourning. Our data support in particular the need for an early intervention of palliative care which could prevent or reduce complicated mourning. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  9. Agrobacterium tumefaciens-MEDIATED IN-PLANTA TRANSFORMATION OF INDONESIAN MAIZE USING pIG121Hm-Cs PLASMID CONTAINING nptII AND hpt GENES

    Directory of Open Access Journals (Sweden)

    Edy Listanto

    2017-05-01

    Full Text Available Maize (Zea mays L. productivity in Indonesia is challenged to be increased using genetic engineering. Recent advances in Agrobacterium tumefaciens-mediated in-planta transforma-tion makes it possible to transform maize with low cost, and simple method. This study aimed to confirm pIG121Hm-Cs plasmid in A. tumefaciens, and to estimate the efficiency level of  A. tumefaciens-mediated in-planta transformation of Indonesian maize by using pIG121Hm-Cs plasmid containing nptII and hpt genes. A series of studies were conducted including confirmation of gene construct of pIG121Hm-Cs plasmid in A. tumefaciens, transformation of four maize lines through A. tumefaciens-mediated in-planta technique, acclimatization of transformant plants and molecular analysis of selected plants using polymerase chain reaction (PCR. The pIG121Hm-Cs plasmid was confirmed via PCR analysis using specific primers of nptII and hpt genes and resulted 700 bp and 500 bp for fragments of nptII and hpt, respectively. After selection, acclimatization and molecular analysis steps, the efficiency levels of transformation of four maize lines were low, ranging from 3.8% to 12.8%. The level of transformation efficiency of ST-27 line was the highest accounting for 12.8% of 45 planted embryos on selection medium based on PCR analysis using specific primer for nptII gene. Overall, A. tumefaciens-mediated in planta transformation on maize floral pistil in this study proved to be successful and rapid. Therefore, this enhanced transformation method will be beneficial for Indonesian maize genetic engineering.

  10. PCI in Patients Supported With CF-LVADs: Indications, Safety, and Outcomes.

    Science.gov (United States)

    Anyanwu, Emeka C; Ota, Takeyoshi; Sayer, Gabriel; Nathan, Sandeep; Jeevanandam, Valluvan; Shah, Atman; Uriel, Nir

    2016-06-01

    Patients with heart failure supported with left ventricular assist devices (LVADs) may require coronary intervention during their support. This case series seeks to explore the indications, safety, and outcomes of percutaneous coronary intervention (PCI) in this population. Electronic medical records of patients with LVADs undergoing PCI at a large academic medical center were reviewed. Demographics, reason for PCI, procedural success, complications, and outcomes were collected. From 2010-2014, a total of 6 patients underwent PCI post LVAD implantation. Three patients had PCI in the early postimplantation period (1-3 days post LVAD implantation) while the other three received it later in the LVAD support period. Three indications for PCI were found in the reviewed cases: right ventricular failure (right coronary artery stenting), bridge to left ventricular recovery, and ventricular tachycardia (VT) storm. All patients were maintained on triple blood thinning therapy (aspirin, clopidogrel, and warfarin). There were no acute complications during the interventions; however, 2 patients died in the early intervention period and 2 died much later. The 2 deaths in the early intervention period were related to fatal gastrointestinal bleeding while on dual-antiplatelet therapy and warfarin, and intractable VT that PCI did not correct. The 2 deaths in the late postintervention period occurred due to unknown causes nearly 1 and 2 years post intervention, respectively. PCI was performed in patients with continuous-flow LVAD with several possible indications and without acute complications. The utility of PCI in this patient population, however, is likely limited by the risk of bleeding related to combined antiplatelet and anticoagulation therapies as well as lack of immediate apparent benefit. Further studies are necessary to better characterize this risk as well as quantify any potential long-term benefits.

  11. Bleeding with the artificial heart: Gastrointestinal hemorrhage in CF-LVAD patients.

    Science.gov (United States)

    Gurvits, Grigoriy E; Fradkov, Elena

    2017-06-14

    Continuous-flow left ventricular assist devices (CF-LVADs) have significantly improved outcomes for patients with end-stage heart failure when used as a bridge to cardiac transplantation or, more recently, as destination therapy. However, its implantations carries a risk of complications including infection, device malfunction, arrhythmias, right ventricular failure, thromboembolic disease, postoperative and nonsurgical bleeding. A significant number of left ventricular assist devices (LVAD) recipients may experience recurrent gastrointestinal hemorrhage, mainly due to combination of antiplatelet and vitamin K antagonist therapy, activation of fibrinolytic pathway, acquired von Willebrand factor deficiency, and tendency to develop small intestinal angiodysplasias due to increased rotary speed of the pump. Gastrointestinal bleeding in LVAD patients remains a source of increased morbidity including the need for blood transfusions, extended hospital stays, multiple readmissions, and overall mortality. Management of gastrointestinal bleeding in LVAD patients involves multidisciplinary approach in stabilizing the patients, addressing risk factors and performing structured endoluminal evaluation with focus on upper gastrointestinal tract including jejunum to find and eradicate culprit lesion. Medical and procedural intervention is largely successful and universal bleeding cessation occurs in transplanted patients.

  12. Hospital costs fell as numbers of LVADs were increasing: experiences from Oslo University Hospital

    Directory of Open Access Journals (Sweden)

    Mishra Vinod

    2012-08-01

    Full Text Available Abstract Background The current study was undertaken to examine total hospital costs per patient of a consecutive implantation series of two 3rd generation Left Ventricle Assist Devices (LVAD. Further we analyzed if increased clinical experience would reduce total hospital costs and the gap between costs and the diagnosis related grouped (DRG-reimbursement. Method Cost data of 20 LVAD implantations (VentrAssist™ from 2005-2009 (period 1 were analyzed together with costs from nine patients using another LVAD (HeartWare™ from 2009-June 2011 (period 2. For each patient, total costs were calculated for three phases - the pre-LVAD implantation phase, the LVAD implantation phase and the post LVAD implant phase. Patient specific costs were obtained prospectively from patient records and included personnel resources, medication, blood products, blood chemistry and microbiology, imaging and procedure costs including operating room costs. Overhead costs were registered retrospectively and allocated to the specific patient by predefined allocation keys. Finally, patient specific costs and overhead costs were aggregated into total hospital costs for each patient. All costs were calculated in 2011-prices. We used regression analyses to analyze cost variations over time and between the different devices. Results The average total hospital cost per patient for the pre-LVAD, LVAD and post-LVAD for period 1 was $ 585, 513 (range 132, 640- 1 247, 299, and the corresponding DRG- reimbursement (2009 was $ 143, 192 . The mean LOS was 54 days (range 12- 127. For period 2 the total hospital cost per patient was $ 413, 185 (range 314, 540- 622, 664 and the corresponding DRG- reimbursement (2010 was $ 136, 963. The mean LOS was 49 days (range 31- 93. The estimates from the regression analysis showed that the total hospital costs, excluding device costs, per patient were falling as the number of treated patients increased. The estimate from the trend variable was -14

  13. Hemorrhoids screening and treatment prior to LVAD: is it a necessity?

    Science.gov (United States)

    Skouri, Hadi; Shurrab, Mohammed; Zahnan, Jad; Deeba, Samer; Sfeir, Pierre; Gharzuddin, Walid; Haj-Yahia, Saleem

    2016-04-12

    Continuous-flow left ventricle assist devices (CF-LVADs) has become an essential modality in the management of stage D heart failure (HF) with significant improvement in survival and quality of life. Due to the durability of such devices and long term support complications such as bleeding and aortic insufficiency has emerged. Bleeding accounts for more than 20 % with the majority being from the gastrointestinal tract. The increase of bleeding tendency are mainly attributed to the loss of large von Willebrand's Factor (vWF) multimers due to shear stress with the chronic intake of anticoagulants. We are reporting two cases of patients with Stage D HF and history of hemorrhoids presenting for LVAD implantation. Many efforts that decrease bleeding related to CF-LVADs will be discussed with focus on hemorrhoids.

  14. Use of PTFE patch for pericardial closure after minimal invasive LVAD implantation.

    Science.gov (United States)

    Mohite, Prashant N; Sabashnikov, Anton; Popov, Aron F; Fatullayev, Javid; Simon, André R

    2016-07-01

    The left ventricular assist device (LVAD) is now a routine therapy for advanced heart failure. The thoracotomy approach for LVAD implantation, in which the left ventricle is approached through a pericardial rent, is becoming popular. We demonstrate closure of the pericardial rent with a polytetrafluoroethylene (PTFE) patch and its advantages. © The Author(s) 2015.

  15. Numerical Simulation of LVAD Inflow Cannulas with Different Tip

    Directory of Open Access Journals (Sweden)

    Guang-Mao Liu

    2012-01-01

    Full Text Available The tip structure of LVAD inflow cannula is one of major factors to lead adverse events such as thrombosis and suction leading to obstruction. In this research, four kinds of tips that had been used in inflow cannulas were selected and designed. The flow field of the four inflow cannulas inserted into the apex of left ventricle (LV was numerically computed by computational fluid dynamics. The flow behavior was analyzed in order to compare the blood compatibility and suction in left ventricle and cannulas after the inflow cannulas with different tips were inserted to the apex of LV. The results showed that the cannula tip structure affected the LVAD performance. Among these four cannulas, the trumpet-tipped inflow cannula owned the best performance in smooth flow velocity distribution without backflow or low-velocity flow so that it was the best in blood compatibility. Nevertheless, the caged tipped cannula was the worst in blood compatibility. And the blunt-tipped and beveled tipped inflow cannulas may obstruct more easily than trumpet and caged tipped inflow cannulas because of their shape. The study indicated that the trumpet tip was the most preferable for the inflow cannula of long-term LVAD.

  16. Mathematical modelling of flow in disc friction LVAD pump

    Science.gov (United States)

    Medvedev, A. E.; Fomin, V. M.; Prikhodko, Yu. M.; Cherniavskiy, A. M.; Fomichev, V. P.; Fomichev, A. V.; Chekhov, V. P.; Ruzmatov, T. M.

    2017-10-01

    The need for blood circulation support systems in the treatment of chronic heart failure is constantly increasing as 20% of patients on the waiting list die every year. Despite the great need for mechanical heart support systems the use of available systems is limited by the high cost. Therefore, further research in the field of circulatory support systems is appropriate taking into account medical and technical requirements. One of the new research areas is viscous friction disk pumps for transporting liquids based on the Tesla pump principle. The experimental model of LVAD disk pump is developed. Analytical dependencies are obtained to optimize the hydraulic parameters of the pump. On their basis, the experimental model of LVAD disk pump was designed and created. The results of analytical and experimental studies of such a pump are presented.

  17. Towards reducing thrombogenicity of LVAD therapy: optimizing surgical and patient management strategies

    Science.gov (United States)

    Chivukula, Venkat Keshav; Lafzi, Ali; Mokadam, Nahush; Beckman, Jennifer; Mahr, Claudius; Aliseda, Alberto

    2017-11-01

    Unfavourable hemodynamics in heart failure patients implanted with left ventricular assist devices (LVAD), due to non-optimal surgical configurations and patient management, strongly influence thrombogenicity. This is consistent with the increase in devastating thromboembolic complications (specifically thrombosis and stroke) in patients, even as the risk of thrombosis inside the device decreases with modern designs. Inflow cannula and outflow graft surgical configurations have been optimized via patient-specific modeling that computes the thrombogenic potential with a combination of Eulerian (endothelial) wall shear stress and Lagrangian (platelet shear history) tracking. Using this view of hemodynamics, the benefits of intermittent aortic valve opening (promoting washout and reducing stagnant flow in the aortic valve region) have been assessed in managing the patient's residual native cardiac output. The use of this methodology to understand the contribution of the hemodynamics in the flow surrounding the LVAD itself to thrombogenesis show promise in developing holistic patient-specific management strategies to minimize stroke risk and enhance efficacy of LVAD therapy. Funded in part by an AHA postdoctoral fellowship 16POST30520004.

  18. LVAD patients' and surrogates' perspectives on SPIRIT-HF: An advance care planning discussion.

    Science.gov (United States)

    Metzger, Maureen; Song, Mi-Kyung; Devane-Johnson, Stephanie

    2016-01-01

    To describe LVAD patients' and surrogates' experiences with, and perspectives on SPIRIT-HF, an advance care planning (ACP) intervention. ACP is important for patients with LVAD, yet little is known about their experiences or those of their surrogates who have participated in ACP discussions. We used qualitative content analysis techniques to conduct a secondary analysis of 28 interviews with patients with LVAD (n = 14) and their surrogates (n = 14) who had participated in an RCT pilot study of SPIRIT-HF. Main themes from the data include: 1) sharing their HF stories was very beneficial; 2) participating in SPIRIT-HF led to greater peace of mind for patients and surrogates; 3) "one size does not fit all" when it comes to timing of ACP discussions. An understanding patient and surrogate perspectives may inform clinicians' approach to ACP discussions. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Avoidance of cellular blood product transfusions in LVAD recipients does not prevent HLA allosensitization.

    Science.gov (United States)

    Stringham, J C; Bull, D A; Fuller, T C; Kfoury, A G; Taylor, D O; Renlund, D G; Karwande, S V

    1999-02-01

    Transfusion of cellular blood products during left ventricular assist device (LVAD) implantation has been associated with HLA allosensitization, resulting in the need for a negative prospective cross-match and prolonged transplant waiting times. In order to prevent this risk, we developed a protocol to avoid transfusion of cellular blood products. The protocol included preoperative patient stabilization, perioperative recombinant erythropoietin and blood conservation strategies, and postoperative monitoring of mixed venous oxygen saturation (SVO2) to assure adequate peripheral oxygen delivery. Panel reactive antibody (PRA) was measured in all patients pre and post LVAD placement to assess HLA sensitization. Seven consecutive patients underwent LVAD implantation without transfusion of blood or platelets, one of whom expired perioperatively. Mean hematocrit was 35.2% preoperatively, and 21.8% postoperatively, reaching a nadir of 20.2%. Postoperative SVO2 was >60% in all patients. In the six survivors, mean hematocrit reach 24.3%, 27.3%, and 33.0% by postoperative day seven, fourteen, and thirty, respectively. PRA in three patients was 0% preoperatively and remained 0% until transplantation after 33, 34, and 50 days of support. In two patients, preoperative PRA was 7% and 17%, dropped to 3% and 0% after thirty days, then progressively rose to 96% and 100% after 60 and 90 days, respectively. In one other patient, preoperative PRA was 0%, remained at 0% after thirty days, then rose to 96% by 60 days. Avoiding transfusion of cellular blood products in LVAD recipients is safe and well tolerated, but does not universally protect from HLA allosensitization. Other factors may also produce sensitization, such as immunogenic components of the LVAD, soluble antigen in fresh frozen plasma, or latent sensitization which is not initially evident in critically ill and possibly anergic patients.

  20. The spectrum of HM Sagittae: a planetary nebula excited by a Wolf--Rayet star

    International Nuclear Information System (INIS)

    Brown, L.W.; Feibelman, W.A.; Hobbs, R.W.; Mccracken, C.W.

    1977-10-01

    Image tube spectrograms of HM Sagittae were obtained. More than 70 emission lines, including several broad emission features, were identified. An analysis of the spectra indicates that HM Sagittae is a planetary nebula excited by a Wolf-Rayet star. The most conspicuous Wolf-Rayet feature is that attributed to a blend of C III at 4650 A and He II at 4686 A

  1. Hemodynamic effects of various support modes of continuous flow LVADs on the cardiovascular system: A numerical study

    Science.gov (United States)

    Song, Zhiming; Gu, Kaiyun; Gao, Bin; Wan, Feng; Chang, Yu; Zeng, Yi

    2014-01-01

    Background The aim of this study was to determine the hemodynamic effects of various support modes of continuous flow left ventricular assist devices (CF-LVADs) on the cardiovascular system using a numerical cardiovascular system model. Material/Methods Three support modes were selected for controlling the CF-LVAD: constant flow mode, constant speed mode, and constant pressure head mode of CF-LVAD. The CF-LVAD is established between the left ventricular apex and the ascending aorta, and was incorporated into the numerical model. Various parameters were evaluated, including the blood assist index (BAI), the left ventricular external work (LVEW), the energy of blood flow (EBF), pulsatility index (PI), and surplus hemodynamic energy (SHE). Results The results show that the constant flow mode, when compared to the constant speed mode and the constant pressure head mode, increases LVEW by 31% and 14%, and EBF by 21% and 15%, respectively, indicating that this mode achieved the best ventricular unloading among the 3 support modes. As BAI is increased, PI and SHE are gradually decreased, whereas PI of the constant pressure head reaches the maximum value. Conclusions The study demonstrates that the continuous flow control mode of the CF-LVAD may achieve the highest ventricular unloading. In contrast, the constant rotational speed mode permits the optimal blood perfusion. Finally, the constant pressure head strategy, permitting optimal pulsatility, should optimize the vascular function. PMID:24793178

  2. Optimal Timing of Heart Transplant After HeartMate II Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Steffen, Robert J; Blackstone, Eugene H; Smedira, Nicholas G; Soltesz, Edward G; Hoercher, Katherine J; Thuita, Lucy; Starling, Randall C; Mountis, Maria; Moazami, Nader

    2017-11-01

    Optimal timing of heart transplantation in patients supported with second-generation left ventricular assist devices (LVADs) is unknown. Despite this, patients with LVADs continue to receive priority on the heart transplant waiting list. Our objective was to determine the optimal timing of transplantation for patients bridged with continuous-flow LVADs. A total of 301 HeartMate II LVADs (Thoratec Corp, Pleasanton, CA) were implanted in 285 patients from October 2004 to June 2013, and 86 patients underwent transplantation through the end of follow-up. Optimal transplantation timing was the product of surviving on LVAD support and surviving transplant. Three-year survival after both HeartMate II implantation and heart transplantation was unchanged when transplantation occurred within 9 months of implantation. Survival decreased as the duration of support exceeded this. Preoperative risk factors for death on HeartMate II support were prior valve operation, prior coronary artery bypass grafting, low albumin, low glomerular filtration rate, higher mean arterial pressure, hypertension, and earlier date of implant. Survival for patients without these risk factors was lowest when transplant was performed within 3 months but was relatively constant with increased duration of support. Longer duration of support was associated with poorer survival for patients with many of these risk factors. Device reimplantation, intracranial hemorrhage, and postimplant dialysis during HeartMate II support were associated with decreased survival. Survival of patients supported by the HeartMate II is affected by preoperative comorbidities and postoperative complications. Transplantation before complications is imperative in optimizing survival. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Low values of 5-hydroxymethylcytosine (5hmC), the "sixth base," are associated with anaplasia in human brain tumors.

    Science.gov (United States)

    Kraus, Theo F J; Globisch, Daniel; Wagner, Mirko; Eigenbrod, Sabina; Widmann, David; Münzel, Martin; Müller, Markus; Pfaffeneder, Toni; Hackner, Benjamin; Feiden, Wolfgang; Schüller, Ulrich; Carell, Thomas; Kretzschmar, Hans A

    2012-10-01

    5-Methylcytosine (5 mC) in genomic DNA has important epigenetic functions in embryonic development and tumor biology. 5-Hydroxymethylcytosine (5 hmC) is generated from 5 mC by the action of the TET (Ten-Eleven-Translocation) enzymes and may be an intermediate to further oxidation and finally demethylation of 5 mC. We have used immunohistochemistry (IHC) and isotope-based liquid chromatography mass spectrometry (LC-MS) to investigate the presence and distribution of 5 hmC in human brain and brain tumors. In the normal adult brain, IHC identified 61.5% 5 hmC positive cells in the cortex and 32.4% 5 hmC in white matter (WM) areas. In tumors, positive staining of cells ranged from 1.1% in glioblastomas (GBMs) (WHO Grade IV) to 8.9% in Grade I gliomas (pilocytic astrocytomas). In the normal adult human brain, LC-MS also showed highest values in cortical areas (1.17% 5 hmC/dG [deoxyguanosine]), in the cerebral WM we measured around 0.70% 5 hmC/dG. levels were related to tumor differentiation, ranging from lowest values of 0.078% 5 hmC/dG in GBMs (WHO Grade IV) to 0.24% 5 hmC/dG in WHO Grade II diffuse astrocytomas. 5 hmC measurements were unrelated to 5 mC values. We find that the number of 5 hmC positive cells and the amount of 5 hmC/dG in the genome that has been proposed to be related to pluripotency and lineage commitment in embryonic stem cells is also associated with brain tumor differentiation and anaplasia. Copyright © 2012 UICC.

  4. Association of HeartMate II left ventricular assist device flow estimate with thermodilution cardiac output.

    Science.gov (United States)

    Hasin, Tal; Huebner, Marianne; Li, Zhuo; Brown, Daniel; Stulak, John M; Boilson, Barry A; Joyce, Lyle; Pereira, Naveen L; Kushwaha, Sudhir S; Park, Soon J

    2014-01-01

    Cardiac output (CO) assessment is important in treating patients with heart failure. Durable left ventricular assist devices (LVADs) provide essentially all CO. In currently used LVADs, estimated device flow is generated by a computerized algorithm. However, LVAD flow estimate may be inaccurate in tracking true CO. We correlated LVAD (HeartMate II) flow with thermodilution CO during postoperative care (day 2-10 after implant) in 81 patients (5,616 paired measurements). Left ventricular assist device flow and CO correlated with a low correlation coefficient (r = 0.42). Left ventricular assist device readings were lower than CO measurements by approximately 0.36 L/min, trending for larger difference with higher values. Left ventricular assist device flow measurements showed less temporal variability compared with CO. Grouping for simultaneous measured blood pressure (BP device flow generally trends with measured CO, but large variability exists, hence flow measures should not be assumed to equal with CO. Clinicians should take into account variables such as high CO, BP, and opening of the aortic valve when interpreting LVAD flow readout. Direct flow sensors incorporated in the LVAD system may allow for better estimation.

  5. The retention mechanism of technetium-99m-HM-PAO

    DEFF Research Database (Denmark)

    Neirinckx, R D; Burke, J F; Harrison, R C

    1988-01-01

    Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation of the b......Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (1:10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min-1. Incubation....... This correspondence of values supports the notion that GSH may be important for the in vivo conversion of 99mTc-labeled HM-PAO to hydrophilic forms and may be the mechanism of trapping in brain and other cells. A kinetic model for the trapping of d,l- and meso-HM-PAO in tissue is developed that is based on data...

  6. The development of 99mTc-d, 1-HM-PAO

    International Nuclear Information System (INIS)

    Bai Lanqin; Huang Jinjie; Fan Li; Bai Suzhen; Li Guoli; Jing Hui; Xiao Lun

    1991-12-01

    The 99m Tc-d,1-HM-PAO is an ideal radiopharmaceutical for regional cerebral blood perfusion imaging. The improvement of synthesis and separation of diastereoisomers leads to obtain high purity (>99%) of d, 1-HM-PAO and meso-HM-PAO. During separation H NMR spectroscopy was used to monitor the relative composition of these two diastereoisomers that can ensure the purity of pligand of d,1-HM-PAO. The intravenous injection of 99m Tc-d,1-HM-PAO was formed by adding fresh 99m Tc washing liquor into a sterile. Pyrogen-free and freeze-dried vial. The radiochemical purity (RCP) of 99m Tc-d,1-HM-PAO was greater than 80%. From the experiments of 99m Tc-d,1-HM-PAO in mice, after two minutes of intravenously (I>V>) administration about 2.24% of injected dose (I.D.)appeared in the brain, and after 24 hours about 72% of radioactivity of injected dose still left in the brain. But for the 99m Tc-meso-HM-PAO after two minutes of i.v. administration, about 1.93% of I.D. appeared in the brain, and 24 hours later, 25% of radioactivity of I.D. was in the brain. This result shows that in the brain the radioactivity of 99m Tc-meso-HM-PAO declines faster than that of 99m Td-d,1-HM-PAO

  7. Technetium-labeled HM-PAO studies in patients with cerebrovascular disease

    International Nuclear Information System (INIS)

    Smith, F.W.; Sharp, P.F.; Gemmell, H.; Evans, N.T.; MacDonald, A.F.

    1986-01-01

    Technetium-labeled hexamethyl-propyleneamineoxime (HM-PAO) is a promising radiopharmaceutical for the demonstration of cerebral blood flow. Twenty-four patients who had experienced either acute stroke (AS) or transient ischemic attack (TIA) were studied by x-ray CT and SPECT using technetium-labeled HM-PAO total of 26 studies. HM-PAO has a cerebral distribution similar to that of iodoamphetamine, but labeling with technetium allows good SPECT imaging on demand in any nuclear medicine department. In ten of the 16 patients who had experienced AS, findings on HM-PAO and CT studies correlated well. In six patients reduced cortical perfusion was detected on HM-PAO imaging, but only small infarcts in the internal capsule were seen on CT. In four of the eight patients who had experienced TIA, neither study revealed any abnormality. In the remaining four, areas of cortical underperfusion were seen on HM-PAO imaging, whereas the CT examination was normal. The findings in this study suggest that HM-PAO imaging is a more sensitive method for demonstrating the extent of cerebral underperfusion in cases of cerebrovascular accident

  8. Development of HM12 cyclotron for PET

    International Nuclear Information System (INIS)

    Morita, Takuzo; Kawama, Tetsuo; Fujii, Kazuo

    2000-01-01

    In Japan, there are at present more than 30 PET (Positron Emission Tomography) facilities. The movements of medical insurance application to the PET diagnosis using [ 18 F] FDG (2-[ 18 F]-fluoro-2-deoxy-glucose) by the Ministry of Health and Welfare are being enhanced by PET related people. Therefore, more clinical centers using PET system are expected to be built in the near future. HM12 cyclotron was developed to meet such market demands for PET, and the prototype machine has been rent to Cyclotron Radio Isotope Center (CYRIC) of Tohoku University since Oct. 1998 for their use of clinical research with positron emitters like 11 C, 13 N, 15 O and 18 F. We got many technical data of HM12 Cyclotron on the clinical base. The data was enough to establish the reliability of HM12 system operation under the clinical condition. The first commercial product of HM12 Cyclotron was delivered to National Cancer Center in March 2000. The final performance test will be finished by the end of June 2000. (author)

  9. Biosynthesis of gold nanoparticles by actinomycete Streptomyces viridogens strain HM10.

    Science.gov (United States)

    Balagurunathan, R; Radhakrishnan, M; Rajendran, R Babu; Velmurugan, D

    2011-10-01

    Biosynthesis of gold nanoparticles by Streptomycetes from Himalayan Mountain was undertaken for the first time. Out of 10 actinomycete strains tested, four strains (D10, HM10, ANS2 and MSU) showed evidence for the intracellular biosynthesis of gold nanoparticles, among which the strain HM10 showed high potency. Presence of spherical and rod shaped gold nanoparticles in mycelium of the strain HM10 was determined by transmission electron microscopy (TEM) and X-ray diffraction analysis. The average particle size ranged from 18-20 nm. UV spectral analysis indicated that the reduction of chloroauric acid (HAuCl4) occurred within 24 h of reaction period. Further, the strain HM10 showed enhanced growth at 1 and 10 mM concentration of HAuCl4. The gold nanoparticles synthesized by the strain HM10 showed good antibacterial activity against S. aureus and E. coli in well-diffusion method. The potential actinomycete HM10 strain was phenotypically characterized and identified as Streptomyces viridogens (HM10). Thus, actinomycete strain HM10 reported in this study is a newly added source for the biosynthesis of gold nanoparticles.

  10. Interaction of Zn(II) with hematite nanoparticles and microparticles: Part 2. ATR-FTIR and EXAFS study of the aqueous Zn(II)/oxalate/hematite ternary system.

    Science.gov (United States)

    Ha, Juyoung; Trainor, Thomas P; Farges, François; Brown, Gordon E

    2009-05-19

    Sorption of Zn(II) to hematite nanoparticles (HN) (av diam=10.5 nm) and microparticles (HM) (av diam=550 nm) was studied in the presence of oxalate anions (Ox2-(aq)) in aqueous solutions as a function of total Zn(II)(aq) to total Ox2-(aq) concentration ratio (R=[Zn(II)(aq)]tot/[Ox2-(aq)]tot) at pH 5.5. Zn(II) uptake is similar in extent for both the Zn(II)/Ox/HN and Zn(II)/Ox/HM ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)](tot)system than for the Zn(II)/Ox/HM ternary and the Zn(II)/HN and Zn(II)/HM binary systems at [Zn(II)(aq)]tot>4 mM. In contrast, Zn(II) uptake for the Zn(II)/HM binary system is a factor of 2 greater than that for the Zn(II)/Ox/HM and Zn(II)/Ox/HN ternary systems and the Zn(II)/HN binary system at [Zn(II)(aq)]totternary system at both R values examined (0.16 and 0.68), attenuated total reflectance Fourier transform infrared (ATR-FTIR) results are consistent with the presence of inner-sphere oxalate complexes and outer-sphere ZnOx(aq) complexes, and/or type A ternary complexes. In addition, extended X-ray absorption fine structure (EXAFS) spectroscopic results suggest that type A ternary surface complexes (i.e., >O2-Zn-Ox) are present. In the Zn(II)/Ox/HN ternary system at R=0.15, ATR-FTIR results indicate the presence of inner-sphere oxalate and outer-sphere ZnOx(aq) complexes; the EXAFS results provide no evidence for inner-sphere Zn(II) complexes or type A ternary complexes. In contrast, ATR-FTIR results for the Zn/Ox/HN sample with R = 0.68 are consistent with a ZnOx(s)-like surface precipitate and possibly type B ternary surface complexes (i.e., >O2-Ox-Zn). EXAFS results are also consistent with the presence of ZnOx(s)-like precipitates. We ascribe the observed increase of Zn(II)(aq) uptake in the Zn(II)/Ox/HN ternary system at [Zn(II)(aq)]tot>or=4 mM relative to the Zn(II)/Ox/HM ternary system to formation of a ZnOx(s)-like precipitate at the hematite nanoparticle/water interface.

  11. hmF2 variability over Havana

    International Nuclear Information System (INIS)

    Lazo, B.; Alazo, K.; Rodriguez, M.; Calzadilla, A.

    2003-01-01

    The hmF2 variability over Havana station (Geo. Latitude 23 deg. N, Geo Longitude 278 deg. E; Dip 54.6 deg. N; Modip: 44.8 deg. N) is presented. In this study different solar and seasonal conditions are considered. The results show that, in general, standard deviation of hmF2 is quite irregular and reaches its values at nighttimes hours. Lower and upper quartiles variability has a similar behaviour to IQ variability, showing its higher values at nighttimes too. (author)

  12. Computational fluid dynamics analysis and PIV validation of a bionic vortex flow pulsatile LVAD.

    Science.gov (United States)

    Xu, Liang; Yang, Ming; Ye, Lin; Dong, Zhaopeng

    2015-01-01

    Hemocompatibility is highly affected by the flow field in Left Ventricular Assistant Devices (LVAD). An asymmetric inflow and outflow channel arrangement with a 45° intersection angle with respect to the blood chamber is proposed to approximate the vascular structure of the aorta and left atrium on the left ventricle. The structure is expected to develop uninterruptible vortex flow state which is similar to the flow state in human left ventricle. The Computational Fluid Dynamics (CFD) asymmetric model is simulated using ANSYS workbench. To validate the velocity field calculated by CFD, a Particle Image Velocimetry (PIV) experiment is conducted. The CFD results show that the proposed blood chamber could generate a shifting vortex flow that would be redirected to the aorta during ejection to form a persistent recirculating flow state, which is similar to the echocardiographic flow state in left ventricle. Both the PIV and the CFD results show the development of a persistent vortex during the pulsatile period. Comparison of the qualitative flow pattern and quantitative probed velocity histories in a pulsatile period shows a good agreement between the CFD and PIV data. The goal of developing persistent quasi intra-ventricle vortex flow state in LVAD is realized.

  13. HM-PAO SPECT in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Cordes, M.; Rummeny, E.; Reissmann, M.; Fox, K.; Panitz, N.; Pfannenstiel, P.

    1987-01-01

    Single photon emission computed tomography (SPECT) after injection of 99m-Tc-HM-PAO was used to examine 34 patients whose clinical findings could not exclude a cerebrovascular disease. In all patients an X-ray computed tomography examination was inconclusive for the clinical-neurological findings. The regional cerebral bloodflow was pathologically disturbed in 10 of 34 patients in the HM-PAO SPECT examination. The detection of the regional cerebral bloodflow with HM-PAO SPECT is helpful in the diagnosis of cerebrovascular disease. (orig.) [de

  14. [Expression and clinical significance of 5hmC in bladder urothelial carcinoma].

    Science.gov (United States)

    Li, Jie; Xu, Yuqiao; Zhang, Zhiwen; Zhang, Ming; Zhang, Zhekai; Zhang, Feng; Li, Qing

    2016-02-01

    To investigate the expression of 5-hydroxymethylcytosine (5hmC) in bladder urothelial carcinoma (UC) and its clinical significance. The expression of 5hmC in 21 cases of UC tissues and pericarcinous urinary tract epithelium was detected by immunohistochemical staining. Then the expression of 5hmC in the surgical resection of UC tissues in 92 cases was also surveyed. Non parametric U Mann-Whitney test was used to analyze the correlation between 5hmC expression and clinical data. Single factor survival analysis was performed by Kaplan-Meier test. The expression of 5hmC in normal urinary tract epithelium and UC tissues was significantly different, but there was no significant difference in the expression of 5hmC between low and high grades of UC tissues as well as between different TNM grades. Kaplan-Meier single factor survival analysis showed that there was no significant correlation between the 5hmC expression level and the survival rate or the recurrence-free survival of UC patients. The expression level of 5hmC in UC tissues is significantly lower than that in pericarcinous urinary tract epithelium. There is no correlation between the 5hmC expression and the progression, prognosis and recurrence of UC.

  15. A novel permanent maglev rotary LVAD with passive magnetic bearings.

    Science.gov (United States)

    Qian, K X; Yuan, H Y; Zeng, P; Ru, W M

    2005-01-01

    It has been widely acknowledged that permanent maglev cannot achieve stability; however, the authors have discovered that stable permanent maglev is possible under the effect of a combination of passive magnetic and nonmagnetic forces. In addition, a rotary left ventricular assist device (LVAD) with passive magnetic bearings has been developed. It is a radially driven impeller pump, having a rotor and a stator. The rotor consists of driven magnets and impeller; the motor coil and pump housing form the stator. Two passive magnetic bearings counteract the attractive force between motor coil iron core and rotor magnets; the rotor thereafter can be disaffiliated from the stator and become levitated under the action of passive magnetic and haemodynamic forces. Because of the pressure difference between the outlet and the inlet of the pump, there is a small flow passing through the gap of rotor and stator, and then entering the lower pressure area along the central hole of the rotor. This small flow comes to a full washout of all blood contacting surfaces in the motor. Moreover, a decreased Bernoulli force in the larger gap with faster flow produces a centring force that leads to stable levitation of the rotor. Resultantly, neither mechanical wear nor thrombosis will occur in the pump. The rotor position detection reveals that the precondition of levitation is a high rotating speed (over 3250 rpm) and a high flow rate (over 1 l min(-1)). Haemodynamic tests with porcine blood indicate that the device as a LVAD requires a rotating speed between 3500 and 4000 rpm for producing a blood flow of 4 - 6 l min(-1) against 100 mmHg mean pressure head. The egg-sized device has a weight of 200 g and an O.D. of 40 mm at its largest point.

  16. The Legacy of Patient H.M. for Neuroscience

    Science.gov (United States)

    Squire, Larry R.

    2009-01-01

    H.M. is probably the best known single patient in the history of neuroscience. His severe memory impairment, which resulted from experimental neurosurgery to control seizures, was the subject of study for five decades until his death in December 2008. Work with H.M. established fundamental principles about how memory functions are organized in the brain. PMID:19146808

  17. Synthesis of the d,I-HM-PAO and formulation of nucleo-equipment for the obtention of {sup 99m} Tc-(d,I)-HM-PAO; Sintesis del d,I-HM-PAO y formulacion de nucleo-equipos para la obtencion de {sup 99m} Tc-(d,I)-HM-PAO

    Energy Technology Data Exchange (ETDEWEB)

    Lezama C, J; Ferro F, G; Alcazar A, P

    1991-09-15

    Most brain imaging radiopharmaceuticals are conventional hydrophilic compounds that are excluded from entering the normal brain by an intact blood-brain barrier (BBB). Under pathologic conditions, the barrier is disrupted and radiotracer concentrates in the leisure for positive identification. {sup 99m} Tc- hexa methyl propylene amine oxime ({sup 99} {sup m} Tc-HM-PAO) is a newer-type lipophilic agent that enter the normal brain through an intact BBB. Studies with this agent offer the promise of measuring cerebral perfusion in the normal and diseased brain. In this paper we present the synthesis and Tc-99m labelling of d,I-HM-PAO. The synthesis of the ligand was carried out by condensation of two molecular equivalents of butanedione monoxime with one molecular equivalent of 1,3 propanediamine provided a bis imine intermediate, which was reduced with sodium borohydride to get the meso and d,I diastereoisomers of HM-PAO. Separation of these was achieved by fractional crystallization. {sup 99m} Tc-(d,I)HM-PAO was obtained by stannous ion reduction of Mo-99/Tc-99m generator eluate in the presence of the ligand. Complex radiochemical purity was determined by instant thin layer chromatography and paper chromatography. Finally, we obtained {sup 99m} Tc-(d,I)HM-PAO with a high radiochemical yield, in excess of 90%. However, for subsequent clinical studies the preparation has to be done a few minutes before application because our product has a low stability. (Author)

  18. Biodegradation of used engine oil by novel strains of Ochrobactrum anthropi HM-1 and Citrobacter freundii HM-2 isolated from oil-contaminated soil.

    Science.gov (United States)

    Ibrahim, Haytham M M

    2016-12-01

    Used engine oil (UEO) constitutes a serious environmental problem due to the difficulty of disposal off or reuse. Ten bacterial strains with biodegradation potential were isolated from UEO-contaminated soil sample using enrichment technique. Two strains which exhibited the highest degradation %, 51 ± 1.2 and 48 ± 1.5, respectively, were selected. Based on the morphological, biochemical characteristics and 16S rRNA sequence analysis, they were identified as Ochrobactrum anthropi HM-1 (accession no: KR360745) and Citrobacter freundii HM-2 (accession no: KR360746). The different conditions which may influence their biodegradation activity, including UEO concentration (1-6 %, v/v), inoculum size (0.5-4 %, v/v), initial pH (6-8), incubation temperature (25-45 °C), and rotation speed (0-200 rpm), were evaluated. The optimum conditions were found to be 2 % UEO, 2 % inoculum size, pH 7.5, incubation temperature 37 °C, and 150 rpm. Under the optimized conditions, strains HM-1, HM-2, and their mixture efficiently degraded UEO, they achieved 65 ± 2.2, 58 ± 2.1, and 80 ± 1.9 %, respectively, after 21 days of incubation. Biodegradation of UEO was confirmed by employing gas chromatography analysis. Gamma radiation (1.5 kGy) enhanced the degradation efficiency of irradiated bacterial mixture (95 ± 2.1 %) as compared to non-irradiated (79 ± 1.6 %). Therefore, strains HM-1 and HM-2 can be employed to develop a cost-effective method for bioremediation of used engine-oil-polluted soil.

  19. HM Sagittae - a most remarkable star

    International Nuclear Information System (INIS)

    Kwok, S.

    1982-01-01

    The author summarises recent observations of HM Sagittae, a symbiotic star that displays activity in every spectral band from X-ray to radio. He concludes that it is best described as a binary system consisting of a late M giant and a hot compact object which is similar to central stars of planetary nebulae. The presence of a wind from the M giant implies that Roche-lobe overflow is not a necessary condition for mass transfer. The complex structure of the circumstellar nebula is possibly the result of wind interactions. The ongoing spectral evolution of HM Sge after its recent outburst makes it an ideal candidate to test models of the symbiotic phenomenon. (Auth.)

  20. Synthesis of the d,I-HM-PAO and formulation of nucleo-equipment for the obtention of 99m Tc-(d,I)-HM-PAO

    International Nuclear Information System (INIS)

    Lezama C, J.; Ferro F, G.; Alcazar A, P.

    1991-09-01

    Most brain imaging radiopharmaceuticals are conventional hydrophilic compounds that are excluded from entering the normal brain by an intact blood-brain barrier (BBB). Under pathologic conditions, the barrier is disrupted and radiotracer concentrates in the leisure for positive identification. 99m Tc- hexa methyl propylene amine oxime ( 99 m Tc-HM-PAO) is a newer-type lipophilic agent that enter the normal brain through an intact BBB. Studies with this agent offer the promise of measuring cerebral perfusion in the normal and diseased brain. In this paper we present the synthesis and Tc-99m labelling of d,I-HM-PAO. The synthesis of the ligand was carried out by condensation of two molecular equivalents of butanedione monoxime with one molecular equivalent of 1,3 propanediamine provided a bis imine intermediate, which was reduced with sodium borohydride to get the meso and d,I diastereoisomers of HM-PAO. Separation of these was achieved by fractional crystallization. 99m Tc-(d,I)HM-PAO was obtained by stannous ion reduction of Mo-99/Tc-99m generator eluate in the presence of the ligand. Complex radiochemical purity was determined by instant thin layer chromatography and paper chromatography. Finally, we obtained 99m Tc-(d,I)HM-PAO with a high radiochemical yield, in excess of 90%. However, for subsequent clinical studies the preparation has to be done a few minutes before application because our product has a low stability. (Author)

  1. hm Reduction in Infinitary Term Graph Rewriting Systems

    DEFF Research Database (Denmark)

    Bahr, Patrick

    2017-01-01

    a corresponding theory of Böhm reduction for term graphs. Our main result is that partial order convergence in a term graph rewriting system can be truthfully and faithfully simulated by metric convergence in the Böhm extension of the system. To prove this result we generalise the notion of residuals...... that `meaningless terms' can be contracted to a fresh constant ⊥. In previous work, we have established that Böhm reduction can be instead characterised by a different mode of convergences of transfinite reductions that is based on a partial order structure instead of a metric space. In this paper, we develop...... and projections to the setting of infinitary term graph rewriting. As ancillary results we prove the infinitary strip lemma and the compression property, both for partial order and metric convergence....

  2. HM Sagittae as a young planetary nebula

    International Nuclear Information System (INIS)

    Kwok, S.; Purton, C.R.

    1979-01-01

    HM Sagittae is suggested to be a very young planetary nebula recently transformed from a red-giant star through continuous mass loss. The observational data for HM Sge have been analyzed in terms of the interacting stellar wind model of planetary nebula formation. The model is in accord with virtually all the spectral data available--radio, optical, and infrared--as well as with the remarkable brightening of HM Sge observed in 1975. In particular, all three gaseous components predicted by the model are observed in the optical spectrum. The density in the newly formed shell is found to be at least 5 x 10 7 cm -3 , a value considerably higher than that found by the conventional analysis, which assumes a single-component homogeneous nebula. The radio spectrum is dominated by free-free emission from the remnant red-giant wind. The infrared spectrum suggests the presence of two dust components, one consisting of silicate grains left over from the red-giant stage and the other of grains newly formed after the 1975 brightening. The low observed shell mass is consistent with the interacting stellar wind model but is not consistent with the conventional sudden-ejection model of planetary nebula formation

  3. The Cognitive Neuroscience of Human Memory Since H.M

    OpenAIRE

    Squire, Larry R.; Wixted, John T.

    2011-01-01

    Work with patient H.M., beginning in the 1950s, established key principles about the organization of memory that inspired decades of experimental work. Since H.M., the study of human memory and its disorders has continued to yield new insights and to improve understanding of the structure and organization of memory. Here we review this work with emphasis on the neuroanatomy of medial temporal lobe and diencephalic structures important for memory, multiple memory systems, visual perception, im...

  4. The pharmacotherapy of the HeartMate II, a continuous flow left ventricular assist device, in patients with advanced heart failure: integration of disease, device, and drug.

    Science.gov (United States)

    Jennings, Douglas L; Chambers, Rachel M; Schillig, Jessica M

    2010-10-01

    Advanced heart failure continues to be a significant cause of morbidity and mortality in the US. Patients with advanced heart failure have a poor prognosis without cardiac transplantation. The use of left ventricular assist devices (LVADs) as destination therapy for these patients is therefore expected to increase in the coming years as technology advances. The HeartMate II, a continuous flow implantable device, is currently the only LVAD that has been approved by the Food and Drug Administration for destination therapy in patients with advanced heart failure. The pharmacotherapy associated with this device is very complex and, therefore, the need for expertly trained clinical pharmacists to care for this expanding patient population will also likely increase. Unfortunately, most pharmacists are unfamiliar with the effect of LVADs on the physiology and pharmacotherapy of a patient's heart failure. The purpose of this article is to give clinical pharmacists an introduction to the most common pharmacotherapeutic issues for patients with LVADs and present practical solutions for managing common drug therapy problems.

  5. Improved Approach With Subcostal Exchange of the HeartMate II Left Ventricular Assist Device: Difference in On and Off Pump?

    Science.gov (United States)

    Gaffey, Ann C; Chen, Carol W; Chung, Jennifer J; Phillips, Emily; Wald, Joyce; Williams, Matthew L; Low, David W; Acker, Michael A; Atluri, Pavan

    2017-11-01

    The HeartMate II (St. Jude Medical, Inc, St. Paul, MN [previously Thoratec]) left ventricular assist device (LVAD) exchange has traditionally involved a redo sternotomy. Alternate minimally invasive subcostal approaches have the advantage of avoiding sternal reentry, excessive bleeding, and prolonged recovery. This retrospective review included patients who underwent an exchange from May 2009 to March 2016. The patients were divided into three cohorts: (1) redo sternotomy, (2) subcostal approach involving cardiopulmonary bypass (CPB) (ON-CPB SC), and (3) subcostal approach off the CPB pump (OFF-CPB SC). Data pertaining to patients' baseline characteristics and outcomes were collected and analyzed. From May 1, 2009 to July 31, 2016, 33 HeartMate II LVAD exchanges were performed. There were 11 redo sternotomies and 22 subcostal exchanges, 12 of which were in the OFF-CPB SC group. There was no significant difference among the groups in terms of age (p = 0.75), sex (p = 0.95), and indication for exchange (p = 0.94). There was a higher red blood cell transfusion requirement within the sternotomy cohort (p rates were equivalent among the cohorts. Exchange of the HeartMate II LVAD can be accomplished with significantly improved recovery time and transfusion requirement through a less invasive subcostal approach when compared with sternotomy. The subcostal approach can be performed safely both on and off cardiopulmonary bypass. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Experimental study of per-rectal portal scintigraphy using 99mTc-HM-PAO

    International Nuclear Information System (INIS)

    Kubota, Hayato; Shinotsuka, Akira; Takenaka, Hiroki; Tamaki, Satoshi.

    1994-01-01

    Usefulness of per-rectal portal scintigraphy by 123 I-IMP has already been admitted. We assessed whether 99m Tc-HM-PAO, another agent used for cerebral blood flow scintigraphy, could be utilized for scintigraphic evaluation of the portal system. Animal experiments were carried out to evaluate the usefulness of the examination. Shunt indices obtained from per-rectal portal scintigraphy by 123 I-IMP and 99m Tc-HM-PAO in shunt models and shunt rate obtained by direct injection of 99m Tc-MAA into the inferior mesenteric vein under laparotomy were compared. Correlation coefficient of each agent with 99m Tc-MAA was 0.90 for 99m Tc-HM-PAO and 0.80 for 123 I-IMP. It was also noted that as larger quantity of the tracer could be administered in 99m Tc-HM-PAO than in 123 I-IMP, absorption from rectum was optimum and liver extraction fraction was 94.4%. Therefore, we concluded that 99m Tc-HM-PAO was useful for per-rectal portal scintigraphy. (author)

  7. The novel immunotoxin HM1.24-ETA′ induces apoptosis in multiple myeloma cells

    International Nuclear Information System (INIS)

    Staudinger, M; Glorius, P; Burger, R; Kellner, C; Klausz, K; Günther, A; Repp, R; Klapper, W; Gramatzki, M; Peipp, M

    2014-01-01

    Despite new treatment modalities, the clinical outcome in a substantial number of patients with multiple myeloma (MM) has yet to be improved. Antibody-based targeted therapies for myeloma patients could make use of the HM1.24 antigen (CD317), a surface molecule overexpressed on malignant plasma cells and efficiently internalized. Here, a novel immunotoxin, HM1.24-ETA′, is described. HM1.24-ETA′ was generated by genetic fusion of a CD317-specific single-chain Fv (scFv) antibody and a truncated variant of Pseudomonas aeruginosa exotoxin A (ETA′). HM1.24-ETA′ inhibited growth of interleukin 6 (IL-6)-dependent and -independent myeloma cell lines. Half-maximal growth inhibition was observed at concentrations as low as 0.3 nM. Target cell killing occurred via induction of apoptosis and was unaffected in co-culture experiments with bone marrow stromal cells. HM1.24-ETA′ efficiently triggered apoptosis of freshly isolated/cryopreserved cells of patients with plasma cell leukemia and MM and was active in a preclinical severe combined immunodeficiency (SCID) mouse xenograft model. Importantly, HM1.24-ETA′ was not cytotoxic against CD317-positive cells from healthy tissue (monocytes, human umbilical vein endothelial cells). These results indicate that CD317 may represent a promising target structure for specific and efficient immunotoxin therapy for patients with plasma cell tumors

  8. Development of 99mTc-labelled the d,1-diasteroisomer of HM-PAO for cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Lun Xiao.

    1989-10-01

    The d,1-diastereoisomer of hexamethyl propyleneamine oxime (HM-PAO) was selected as the preferred ligand for Tc-99m as a radiotracer for cerebral perfusion imaging. Further improvement of the synthesis and isolation method of HM-PAO resulted in pure d,1-HM-PAO and pure meso-HM-PAO. The neutral, lipophilic Tc-99m complexes of d,1-HM-PAO and meso-HM-PAO were formed in high yield by stannous reduction of Mo-99/Tc-99m generator eluate, respectively. Two minutes following i.v. administration of Tc-99m-d,1-HM-PAO in mice, 2.24% of the injected dose appears in the brain. Little washout of the tracer is observed up to 24-hour post injection. Two minutes following i.v. administration of Tc-99m-meso-HM-PAO in mice, 1.9% of the injected dose appears in the brain. The radioactivity of Tc-99m-meso-HM-PAO declined faster than that of Tc-99m-d,1-HM-PAO did in the brain up to 24-hour post injection. 12 refs, 5 figs, 5 tabs

  9. Enhancement of arachidonic acid signaling pathway by nicotinic acid receptor HM74A

    International Nuclear Information System (INIS)

    Tang, Yuting; Zhou, Lubing; Gunnet, Joseph W.; Wines, Pamela G.; Cryan, Ellen V.; Demarest, Keith T.

    2006-01-01

    HM74A is a G protein-coupled receptor for nicotinic acid (niacin), which has been used clinically to treat dyslipidemia for decades. The molecular mechanisms whereby niacin exerts its pleiotropic effects on lipid metabolism remain largely unknown. In addition, the most common side effect in niacin therapy is skin flushing that is caused by prostaglandin release, suggesting that the phospholipase A 2 (PLA 2 )/arachidonic acid (AA) pathway is involved. Various eicosanoids have been shown to activate peroxisome-proliferator activated receptors (PPAR) that play a diverse array of roles in lipid metabolism. To further elucidate the potential roles of HM74A in mediating the therapeutic effects and/or side effects of niacin, we sought to explore the signaling events upon HM74A activation. Here we demonstrated that HM74A synergistically enhanced UTP- and bradykinin-mediated AA release in a pertussis toxin-sensitive manner in A431 cells. Activation of HM74A also led to Ca 2+ -mobilization and enhanced bradykinin-promoted Ca 2+ -mobilization through Gi protein. While HM74A increased ERK1/2 activation by the bradykinin receptor, it had no effects on UTP-promoted ERK1/2 activation.Furthermore, UTP- and bradykinin-mediated AA release was significantly decreased in the presence of both MAPK kinase inhibitor PD 098059 and PKC inhibitor GF 109203X. However, the synergistic effects of HM74A were not dramatically affected by co-treatment with both inhibitors, indicating the cross-talk occurred at the receptor level. Finally, stimulation of A431 cells transiently transfected with PPRE-luciferase with AA significantly induced luciferase activity, mimicking the effects of PPARγ agonist rosiglitazone, suggesting that alteration of AA signaling pathway can regulate gene expression via endogenous PPARs

  10. Enhancement of arachidonic acid signaling pathway by nicotinic acid receptor HM74A

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yuting [Endocrine Therapeutics and Metabolic Disorders, Johnson and Johnson Pharmaceutical Research and Development, L.L.C., 1000 Rt. 202, Raritan, NJ 08869 (United States); Zhou, Lubing [Endocrine Therapeutics and Metabolic Disorders, Johnson and Johnson Pharmaceutical Research and Development, L.L.C., 1000 Rt. 202, Raritan, NJ 08869 (United States); Gunnet, Joseph W [Endocrine Therapeutics and Metabolic Disorders, Johnson and Johnson Pharmaceutical Research and Development, L.L.C., 1000 Rt. 202, Raritan, NJ 08869 (United States); Wines, Pamela G [Endocrine Therapeutics and Metabolic Disorders, Johnson and Johnson Pharmaceutical Research and Development, L.L.C., 1000 Rt. 202, Raritan, NJ 08869 (United States); Cryan, Ellen V [Endocrine Therapeutics and Metabolic Disorders, Johnson and Johnson Pharmaceutical Research and Development, L.L.C., 1000 Rt. 202, Raritan, NJ 08869 (United States); Demarest, Keith T [Endocrine Therapeutics and Metabolic Disorders, Johnson and Johnson Pharmaceutical Research and Development, L.L.C., 1000 Rt. 202, Raritan, NJ 08869 (United States)

    2006-06-23

    HM74A is a G protein-coupled receptor for nicotinic acid (niacin), which has been used clinically to treat dyslipidemia for decades. The molecular mechanisms whereby niacin exerts its pleiotropic effects on lipid metabolism remain largely unknown. In addition, the most common side effect in niacin therapy is skin flushing that is caused by prostaglandin release, suggesting that the phospholipase A{sub 2} (PLA{sub 2})/arachidonic acid (AA) pathway is involved. Various eicosanoids have been shown to activate peroxisome-proliferator activated receptors (PPAR) that play a diverse array of roles in lipid metabolism. To further elucidate the potential roles of HM74A in mediating the therapeutic effects and/or side effects of niacin, we sought to explore the signaling events upon HM74A activation. Here we demonstrated that HM74A synergistically enhanced UTP- and bradykinin-mediated AA release in a pertussis toxin-sensitive manner in A431 cells. Activation of HM74A also led to Ca{sup 2+}-mobilization and enhanced bradykinin-promoted Ca{sup 2+}-mobilization through Gi protein. While HM74A increased ERK1/2 activation by the bradykinin receptor, it had no effects on UTP-promoted ERK1/2 activation.Furthermore, UTP- and bradykinin-mediated AA release was significantly decreased in the presence of both MAPK kinase inhibitor PD 098059 and PKC inhibitor GF 109203X. However, the synergistic effects of HM74A were not dramatically affected by co-treatment with both inhibitors, indicating the cross-talk occurred at the receptor level. Finally, stimulation of A431 cells transiently transfected with PPRE-luciferase with AA significantly induced luciferase activity, mimicking the effects of PPAR{gamma} agonist rosiglitazone, suggesting that alteration of AA signaling pathway can regulate gene expression via endogenous PPARs.

  11. Strategi Pemasaran Makanan Tradisional Asam Pedas Ikan Patin Khas Pekanbaru pada Restoran Pondok Patin Hm. Yunus

    OpenAIRE

    Gunawan, Dwi Yanda; Sulistyani, Andri

    2017-01-01

    Due of the Pondok Patin HM. Yunus Restaurant in Pekanbaru that capture this opportunity is Pondok Patin HM. Yunus Restaurant. The aims of this sturly are identify the implemented marketing strategy, idendify the determinals of marketing strategy forfulation, formulated new marketing strategy. Pondok Patin HM. Yunus Restaurant uses 4 p marketing mix : 1) Product 2) Price 3) Promotion 4) Place. Pondok Patin HM. Yunus restaurant was one of restaurant who providing the signature main course of Pe...

  12. Comparison of acoustic fields produced by the original and upgraded HM-3 lithotripter

    Science.gov (United States)

    Zhou, Yufeng; Zhu, Songlin; Dreyer, Thomas; Liebler, Marko; Zhong, Pei

    2003-10-01

    To reduce tissue injury in shock wave lithotripsy (SWL) while maintaining satisfactory stone comminution, an original HM-3 lithotripter was upgraded by a reflector insert to suppress large intraluminal bubble expansion, which is a primary mechanism of vascular injury in SWL. The pressure waveforms produced by the original and upgraded HM-3 lithotripter were measured by using a fiber optical probe hydrophone (FOPH), which was scanned both along and transverse to the lithotripter axis at 1-mm step using a computer-controlled 3-D positioning system. At F2, the pressure waveform produced by the upgraded HM-3 lithotripter at 22 kV has a distinct dual-pulse structure, with a leading shock wave of ~45 MPa from the reflector insert and a 4-μs delayed second pulse of ~15 MPa reflected from the uncovered bottom surface of the original HM-3 reflector. The beam sizes of the original and upgraded HM-3 lithotripter are comparable in both axial and lateral directions. The pressure waveforms measured at the reflector aperture will be used as input to the KZK equation to predict the lithotripter shock wave at F2. Furthermore, bubble dynamics predicted by the Gilmore model will be compared with experimental observation by high-speed imaging. [Work supported by NIH.

  13. 99mTc HM-PAO brain perfusion SPECT in brain death

    International Nuclear Information System (INIS)

    Bonetti, M.G.; Ciritella, P.; Valle, G.; Perrone, E.

    1995-01-01

    We have easily carried out and interpreted 99m Tc HM-PAO SPECT in a consecutive series of 40 comatose patients with brain damage, without discontinuing therapy. Brain death was diagnosed in 7 patients, by recognising absence of brain perfusion, as shown by no intracranial radionuclide uptake. In patients in whom perfusion was seen on brain scans, HM-PAO SPECT improved assessment of the extent of injury, which in general was larger than suggested by CT. (orig.)

  14. The importance of strategic management : A case study of H&M

    OpenAIRE

    Ding, Huiru

    2011-01-01

    Hennes & Mauritz (H&M) is a 100 billion Sweden company,engaged in designing and retailing of fashion apparel and accessories. The company offers a range of apparel, cosmetics, footwear and accessories for men, women, children and teenagers. H&M primarily operates in Europe, North America and Asia, and has a presence in over 38 countries. The company is headquartered in Stockholm, Sweden and employs approximately 87,000 people on a full-time basis. This thesis focused on the strategic...

  15. The Cognitive Neuroscience of Human Memory Since H.M

    Science.gov (United States)

    Squire, Larry R.; Wixted, John T.

    2011-01-01

    Work with patient H.M., beginning in the 1950s, established key principles about the organization of memory that inspired decades of experimental work. Since H.M., the study of human memory and its disorders has continued to yield new insights and to improve understanding of the structure and organization of memory. Here we review this work with emphasis on the neuroanatomy of medial temporal lobe and diencephalic structures important for memory, multiple memory systems, visual perception, immediate memory, memory consolidation, the locus of long-term memory storage, the concepts of recollection and familiarity, and the question of how different medial temporal lobe structures may contribute differently to memory functions. PMID:21456960

  16. Characterization of biosurfactants produced by novel strains of Ochrobactrum anthropi HM-1 and Citrobacter freundii HM-2 from used engine oil-contaminated soil

    Directory of Open Access Journals (Sweden)

    Haytham M.M. Ibrahim

    2018-03-01

    Full Text Available Microbial surfactants are widely used for industrial, agricultural, food, cosmetics, pharmaceutical, and medical applications. In this study, two bacterial strains namely, Ochrobactrum anthropi HM-1 and Citrobacter freundii HM-2, previously isolated from used engine oil contaminated soil, and capable of producing biosurfactants, were used. Their cell-free culture broth showed positive results toward five screening tests (hemolysis in blood agar, drop collapse, oil displacement, emulsification activity (E24, and surface tension (ST reduction. They reduced the ST of growth medium (70 ± 0.9 to 30.8 ± 0.6 and 32.5 ± 1.3 mN/m, respectively. The biosurfactants were classified as anionic biomolecules. Based on TLC pattern and FT-IR analysis, they were designated as glycolipids (rhamnolipid. Waste frying oil was feasibly used as a cheap and dominant carbon source for biosurfactants production; 4.9 and 4.1 g/l were obtained after 96 h of incubation, respectively. Compared with non-irradiated cells, gamma-irradiated cells (1.5 kGy revealed enhanced biosurfactant production by 56 and 49% for HM-1 and HM-2, respectively. The biosurfactants showed good stability after exposure to extreme conditions [temperatures (50–100 °C for 30 min, pH (2–12 and salinity (2–10% NaCl], they retained 83 and 79.3% of their E24, respectively, after incubation for a month, under extreme conditions. Biosurfactants effectively recovered up to 70 and 67% of the residual oil, respectively, from oil-saturated sand pack columns. These biosurfactants are an interesting biotechnological product for many environmental and industrial applications. Keywords: Ochrobactrum anthropi, Citrobacter freundii, Biosurfactant, Characterization, Stability

  17. 153Sm-HM for arthritic knee pain. Estimated dosimetry

    International Nuclear Information System (INIS)

    Hardy-Pérez, Alberto E.; Torres-García, Eugenio; Mitsoura, Eleni; Jiménez-Mancilla, Nallely P.; Arteaga-de-Murphy, Consuelo; Pedraza-López, Martha

    2012-01-01

    Osteoarthritis is the most common type of arthropathy and after cardiovascular diseases is the most disabling disease in developing countries. The dosimetry for the clinical application of 153-samarium-hydroxymacroaggregates ( 153 Sm-HM) for radiation synovectomy (RSV) and palliative treatment for arthritic pain, as far as we know, has not been reported. The aim of this research was to estimate the radiation dose necessary for synovial ablation and pain palliation with minimum risk to the patient. 153 Sm-HM (370 MBq) was administered intra-articularly in a patient with severe knee pain and hindered motility. Regions of interest drawn on sequential, conjugated, anterior and posterior scintigraphy images were used to obtain the respective activity. The data was entered into a knee joint histological-geometric model designed with micrometric dimensions to represent the synovial cell layers. The Monte Carlo code was used to calculate the absorbed dose in each of the 12 model-cells representing the distance from the synovial liquid to the cartilage or bone. The absorbed dose in the synovial cavity was 114 Gy which is sufficient energy for RSV. The treated patient referred little pain and higher motility with no adverse reactions. 153 Sm-HM is a potentially valid radiopharmaceutical for RSV, which effectively palliates knee pain.

  18. Basic and clinical evaluation of regional cerebral perfusion scintigraphy of 99mTc-HM-PAO

    International Nuclear Information System (INIS)

    Tsukatani, Yasushi; Nakamura, Kayoko; Fujii, Hiroshi

    1988-01-01

    Radiochemical purity of 99m Tc-HM-PAO decreased rapidly after preparation. 99m Tc activity of the whole brain increased rapidly after venous injection, and changed very little after 3 minutes later. 99m Tc-HM-PAO scintigram showed the wider abnormal perfusion area than CT scanning did. Hypoperfusion area found by IMP tended to be wider than that by HM-PAO. There were no side effects observed of all cases. (author)

  19. New Insights into 5hmC DNA Modification: Generation, Distribution and Function

    Directory of Open Access Journals (Sweden)

    Dong-Qiao Shi

    2017-07-01

    Full Text Available Dynamic DNA modifications, such as methylation/demethylation on cytosine, are major epigenetic mechanisms to modulate gene expression in both eukaryotes and prokaryotes. In addition to the common methylation on the 5th position of the pyrimidine ring of cytosine (5mC, other types of modifications at the same position, such as 5-hydroxymethyl (5hmC, 5-formyl (5fC, and 5-carboxyl (5caC, are also important. Recently, 5hmC, a product of 5mC demethylation by the Ten-Eleven Translocation family proteins, was shown to regulate many cellular and developmental processes, including the pluripotency of embryonic stem cells, neuron development, and tumorigenesis in mammals. Here, we review recent advances on the generation, distribution, and function of 5hmC modification in mammals and discuss its potential roles in plants.

  20. Variable dust obscuration in the symbiotic Mira and very slow Nova, HM Sge

    International Nuclear Information System (INIS)

    Munari, U.; Whitelock, P.A.

    1989-01-01

    New infrared photometry is presented for the symbiotic Mira, HM Sge. Using this and published data a pulsation period of 527 day is derived. In addition to the normal pulsational modulation, the light curve for HM Sge has shown a distinct fading and reddening, starting in 1985. This is interpreted as a dust-obscuration event, and its possible association with the binary orbit is discussed. (author)

  1. SPECT with [99mTc]-d,l-hexamethyl-propylene amine oxime (HM-PAO) compared with regional cerebral blood flow measured by PET

    DEFF Research Database (Denmark)

    Yonekura, Y; Nishizawa, S; Mukai, Thomas Søgaard

    1988-01-01

    In order to validate the use of technetium-99m-d,l-hexamethylpropyleneamine oxime (HM-PAO) as a flow tracer, a total of 21 cases were studied with single photon emission computerized tomography (SPECT), and compared to regional cerebral blood flow (rCBF) measured by position emission tomography...... (PET) using the oxygen-15 CO2 inhalation technique. Although HM-PAO SPECT and rCBF PET images showed a similar distribution pattern the HM-PAO SPECT image showed less contrast between high and low activity flow regions than the rCBF image and a nonlinear relationship between HM-PAO activity and r......CBF was shown. Based on the assumption of flow-dependent backdiffusion of HM-PAO from the brain, we applied a "linearization algorithm" to correct the HM-PAO SPECT images. The corrected HM-PAO SPECT images revealed a good linear correlation with rCBF (r = 0.901, p less than 0.001). The results indicated HM-PAO...

  2. The retention of [99mTc]-d,l-HM-PAO in the human brain after intracarotid bolus injection

    DEFF Research Database (Denmark)

    Lassen, N A; Andersen, A R; Friberg, L

    1988-01-01

    [99mTc]-d,l-HM-PAO (HM-PAO) was injected rapidly into the internal carotid artery and its retention in the brain was recorded by external scintillation cameras in eight human subjects. A model is described based on three compartments: the lipophilic tracer in the blood pool of the brain, the lipo......[99mTc]-d,l-HM-PAO (HM-PAO) was injected rapidly into the internal carotid artery and its retention in the brain was recorded by external scintillation cameras in eight human subjects. A model is described based on three compartments: the lipophilic tracer in the blood pool of the brain...

  3. Partial LVAD restores ventricular outputs and normalizes LV but not RV stress distributions in the acutely failing heart in silico

    OpenAIRE

    Sack, Kevin L.; Baillargeon, Brian; Acevedo-Bolton, Gabriel; Genet, Martin; Rebelo, Nuno; Kuhl, Ellen; Klein, Liviu; Weiselthaler, Georg M.; Burkhoff, Daniel; Franz, Thomas; Guccione, Julius M.

    2016-01-01

    Purpose: Heart failure is a worldwide epidemic that is unlikely to change as the population ages and life expectancy increases. We sought to detail significant recent improvements to the Dassault Systèmes Living Heart Model (LHM) and use the LHM to compute left ventricular (LV) and right ventricular (RV) myofiber stress distributions under the following 4 conditions: (1) normal cardiac function; (2) acute left heart failure (ALHF); (3) ALHF treated using an LV assist device (LVAD) flow rate o...

  4. Virtual Mission First Results Supporting the WATER HM Satellite Concept

    Science.gov (United States)

    Alsdorf, D.; Andreadis, K.; Lettenmaier, D.; Moller, D.; Rodriguez, E.; Bates, P.; Mognard, N.; Participants, W.

    2007-12-01

    Surface fresh water is essential for life, yet we have surprisingly poor knowledge of its variability in space and time. Similarly, ocean circulation and ocean-atmosphere interactions fundamentally drive weather and climate variability, yet the global ocean current and eddy field (e.g., the Gulf Stream) that affects ocean circulation is poorly known. The Water And Terrestrial Elevation Recovery Hydrosphere Mapper satellite mission concept (WATER HM or SWOT per the NRC Decadal Survey) is a swath-based interferometric-altimeter designed to acquire elevations of ocean and terrestrial water surfaces at unprecedented spatial and temporal resolutions. WATER HM will have tremendous implications for estimation of the global water cycle, water management, ocean and coastal circulation, and assessment of many water-related impacts from climate change (e.g., sea level rise, carbon evasion, etc.). We describe a hydrological "virtual mission" (VM) for WATER HM which consists of: (a) A hydrodynamic-instrument simulation model that maps variations in water levels along river channels and across floodplains. These are then assimilated to estimate discharge and to determine trade-offs between resolutions and mission costs. (b) Measurements from satellites to determine feasibility of existing platforms for measuring storage changes and estimating discharge. First results demonstrate that: (1) Ensemble Kalman filtering of VM simulations recover water depth and discharge, reducing the discharge RMSE from 23.2% to 10.0% over an 84- day simulation period, relative to a simulation without assimilation. The filter also shows that an 8-day overpass frequency produces discharge relative errors of 10.0%, while 16-day and 32-day frequencies result in errors of 12.1% and 16.9%, respectively. (2) SRTM measurements of water surfaces along the Mississippi, Missouri, Ohio, and Amazon rivers, as well as smaller tributaries, show height standard deviations of 5 meters or greater (SRTM is the

  5. Investigating the Role of Interventricular Interdependence in Development of Right Heart Dysfunction During LVAD Support: A Patient-Specific Methods-Based Approach

    Directory of Open Access Journals (Sweden)

    Kevin L. Sack

    2018-05-01

    Full Text Available Predictive computation models offer the potential to uncover the mechanisms of treatments whose actions cannot be easily determined by experimental or imaging techniques. This is particularly relevant for investigating left ventricular mechanical assistance, a therapy for end-stage heart failure, which is increasingly used as more than just a bridge-to-transplant therapy. The high incidence of right ventricular failure following left ventricular assistance reflects an undesired consequence of treatment, which has been hypothesized to be related to the mechanical interdependence between the two ventricles. To investigate the implication of this interdependence specifically in the setting of left ventricular assistance device (LVAD support, we introduce a patient-specific finite-element model of dilated chronic heart failure. The model geometry and material parameters were calibrated using patient-specific clinical data, producing a mechanical surrogate of the failing in vivo heart that models its dynamic strain and stress throughout the cardiac cycle. The model of the heart was coupled to lumped-parameter circulatory systems to simulate realistic ventricular loading conditions. Finally, the impact of ventricular assistance was investigated by incorporating a pump with pressure-flow characteristics of an LVAD (HeartMate II™ operating between 8 and 12 k RPM in parallel to the left ventricle. This allowed us to investigate the mechanical impact of acute left ventricular assistance at multiple operating-speeds on right ventricular mechanics and septal wall motion. Our findings show that left ventricular assistance reduces myofiber stress in the left ventricle and, to a lesser extent, right ventricle free wall, while increasing leftward septal-shift with increased operating-speeds. These effects were achieved with secondary, potentially negative effects on the interventricular septum which showed that support from LVADs, introduces unnatural bending

  6. Heat Generation in Axial and Centrifugal Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Yost, Gardner; Joseph, Christine Rachel; Royston, Thomas; Tatooles, Antone; Bhat, Geetha

    Despite increasing use of left ventricular assist devices (LVADs) as a surgical treatment for advanced heart failure in an era of improved outcomes with LVAD support, the mechanical interactions between these pumps and the cardiovascular system are not completely understood. We utilized an in vitro mock circulatory loop to analyze the heat production incurred by operation of an axial flow and centrifugal flow LVAD. A HeartMate II and a HeartWare HVAD were connected to an abbreviated flow loop and were implanted in a viscoelastic gel. Temperature was measured at the surface of each LVAD. Device speed and fluid viscosity were altered and, in the HeartMate II, as artificial thrombi were attached to the inflow stator, impeller, and outflow stator. The surface temperatures of both LVADs increased in all trials and reached a plateau within 80 minutes of flow initiation. Rate of heat generation and maximum system temperature were greater when speed was increased, when viscosity was increased, and when artificial thrombi were attached to the HeartMate II impeller. Normal operation of these two widely utilized LVADs results in appreciable heat generation in vitro. Increased pump loading resulted in more rapid heat generation, which was particularly severe when a large thrombus was attached to the impeller of the HeartMate II. While heat accumulation in vivo is likely minimized by greater dissipation in the blood and soft tissues, focal temperature gains with the pump housing of these two devices during long-term operation may have negative hematological consequences.

  7. Reduced Anxiety and Depression in Patients With Advanced Heart Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Mahoney, Edward; Tatooles, Antone

    Despite the high prevalence of depression and anxiety in patients with advanced heart failure, the effects of left ventricular assist device (LVAD) implantation on these critically important aspects of mental health are not well understood. We sought to assess changes in depression and anxiety following LVAD implantation. The Beck Depression Inventory-II (BDI-II) and Beck Anxiety Inventory (BAI) were administered to 54 patients by a clinical psychologist at a mean of 12 days before LVAD implantation and 251 days after implantation. Patient demographics and clinical data were collected concurrently to psychologic testing. Changes in BDI-II, BAI, and clinical markers of heart failure were assessed using paired t-tests. A p Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  8. Cerebral blood flow imaging by I-123 IMP and Tc-99m HM-PAO

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Koichi; Yoshikawa, Kyosan; Minoshima, Satoshi; Imaseki, Keiko; Arimizu, Noboru; Yamaura, Akira; Uematsu, Sadao

    1988-02-01

    SPECT studies with either N-isopropyl-p-(I-123)iodo- amphetamine (I-123 IMP) or Tc-99m hexamethyl propylene amine oxime (Tc-99m HM-PAO) were cuncurrently performed in 12 patients with brain disorders, comprising cerebral infarction (7), cerebral aneurysm (one), intracranial hemorrhage (3), and subdural hematoma (one). Whereas I-123 IMP was taken up gradually into the brain, the uptake of Tc-99m-HM-PAO in the brain reached the peak immediately after the iv injection, with 90% or more remaining constant by 15 min postinjection. On early SPECT images, a high uptake of I-123 IMP was observed in the lung, and the uptake of Tc-99m HM-PAO was observed as well in the soft tissue of cervical region. In all patients except for one, decreased rCBF was observed in the lesions on both I-123 and Tc-99m SPECT scans. Both of the radiopharmaceuticals were analogous in that decreased blood flow corresponded to cerebral lesions. (Namekawa, K).

  9. HM-PAO-SPECT of the brain in a new-born child

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, F.; Biersack, H.J.; Bindl, L.

    1988-08-01

    HM-PAO-SPECT of the brain was performed in a 14 days old new-born child. Diencephalon, brain stem and cerebellum showed a relative high tracer accumulation; there was nearly no accumulation in the neocortex.

  10. Single-cell 5hmC sequencing reveals chromosome-wide cell-to-cell variability and enables lineage reconstruction

    NARCIS (Netherlands)

    Mooijman, Dylan; Dey, Siddharth S; Boisset, Jean-Charles; Crosetto, Nicola; van Oudenaarden, Alexander

    2016-01-01

    The epigenetic DNA modification 5-hydroxymethylcytosine (5hmC) has crucial roles in development and gene regulation. Quantifying the abundance of this epigenetic mark at the single-cell level could enable us to understand its roles. We present a single-cell, genome-wide and strand-specific 5hmC

  11. Diagnosis of infected bone and joint diseases with 99mTc-HM-PAO labeled leukocytes

    International Nuclear Information System (INIS)

    Kanegae, Kakuko; Itoh, Kazuo; Tsukamoto, Eriko; Nagao, Kazuhiko; Nakada, Kunihiro; Hurudate, Masayori

    1992-01-01

    The usefulness of 99m Tc-hexamethylpropylene amine oxime (HM-PAO) labeled leukocytes scans was studied in 15 patients with suspected infection of the bone and joints. All spot images of lesions were obtained 4 and 24 hours after injection of 70.3-236.8 MBq (a mean, 149.5 MBq). 99m Tc-HM-PAO leukocytes scans were positive in 5 patients, negative in 8, and equivocal in 2. It had a sensitivity of 83% (5/6), specificity of 100% (6/6), and accuracy of 93% (14/15) for diagnosing infections. Equivocal uptake, seen on the 4-hr image in 2 patients, became negative on the 24-hr image. In view of ready availability and simple labeling procedure, 99m Tc-HM-PAO labeled leukocytes scans can be used as one of the specific diagnostic procedures for infections. (N.K.)

  12. Cerebral uptake and retention of 99Tcsup(m)-hexamethylpropyleneamine oxime (99Tcsup(m)-HM-PAO)

    International Nuclear Information System (INIS)

    Holmes, R.A.; Chaplin, S.B.; Royston, K.G.; Missouri Univ., Columbia

    1985-01-01

    A new radiopharmaceutical, 99 Tcsup(m)-hexamethylpropyleneamine oxime ( 99 Tcsup(m)-HM-PAO) is described. This agent displays considerable promise for imaging cerebral blood flow. In studies in rats and one human volunteer, 99 Tcsup(m)-HM-PAO demonstrates good brain uptake, prolonged retention of activity in the brain, and slow regional redistribution. These properties suggest that this new radiopharmaceutical is ideal for single photon emission tomographic (SPECT) imaging of cerebral blood flow. (author)

  13. Aortic valve biomechanics during LVAD support: Implementation in a bioreactor design and preliminary testing

    Science.gov (United States)

    Jamal, Madiha

    Although Left Ventricle Assist Device (LVAD) support has enhanced the quality of life for many heart failure patients, its prolonged in-vivo implantation causes change in hemodynamics and biomechanics of the aortic heart valve eventually leading to development of aortic insufficiency (AI). The LVAD decreases pressure in the left ventricle, leading to high transvalvular pressure and reduced aortic valve opening. Our hypothesis is that the increased pressure leads to increased mechanical stretch in the aortic valve leaflets, inducing a cascade of responses that ultimately result in local tissue fibrosis and AI. The goal of this study is to investigate the mechanism behind this hypothesis using the methods of tissue engineering. A bioreactor has been built that imparts cyclic stretch and flow to small 3-D constructs of living cells cultured in a silicone membrane. The approach is to use this device for in vitro tissue culture of vascular interstitial cells (VICs) embedded in a collagen gel, which will be subjected to normal and altered stretch and shear representative of the in vivo valve biomechanics. The bioreactor was validated to measure the amount of stretch and shear it can impart to closely replicate in-vivo conditions using PIV technique and ImageJ software. Mean longitudinal strain of 0.037cm (SD= +/-0.013cm) was recorded with mean perpendicular strain being 0.0046cm (SD= +/-0.0169cm). Measured average shear stress imparted at 100ml/min was 2.735 dynes/cm2 (SD= +/-2.25 dynes/cm2) with 6.21 dynes/cm2 (SD= +/-3.35 dynes/cm2) at 200ml/min. The cells that underwent cycles of stretch and shear in the bioreactor were screened for formation of myofibroblast using techniques of immunohistochemistry. The marker used was ? smooth muscle actin (SMA) which identifies pathological differentiation of the CPCs to myofibroblast. Yhe expression of the myofibroblast phenotype is a feature of valvupathy. In case of Shear Vs Static control, the mean value for SMA expression for

  14. MELCOR simulation of steam condensation effect on hydrogen behavior in THAI HM-2 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seongnyeon; Lee, Jung-Jae; Cho, Yong-Jin [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of); Kim, Sung Joong [Hanyang University, Seoul (Korea, Republic of)

    2015-10-15

    In this study, MELCOR simulation was carried out for THAI HM-2 experiment of OECD. As a results, stratification of hydrogen cloud was reasonably captured in MELCOR simulation. Furthermore, the pressure from simulation results in cases where mass transfer coefficient of MELCOR condensation model was modified was good agreement with the experimental results. Containment Filtered Ventilation System (CFVS) has been introduced as facility to prevent containment failure during severe accident. However, possibility of hydrogen risk has been issued due to inflow of hydrogen, condensation and removal of steam and complicated inner structure in CFVS. Preferentially benchmark work for THAI HM-2 experiment of OECD was decided to validate the methodology before detailed assessment of hydrogen risk in CFVS. The objectives of THAI HM-2 experiment were evaluation of hydrogen behavior, verification of numerical analysis tools and so on. In this paper, therefore, MELCOR simulation was carried out in comparison with the experiment results. Additionally, steam condensation effect was considered for detailed simulation. Hydrogen concentration from MELCOR results was underestimated in comparison to the experimental results.

  15. Sustainable Fashion Supply Chain: Lessons from H&M

    Directory of Open Access Journals (Sweden)

    Bin Shen

    2014-09-01

    Full Text Available Sustainability is significantly important for fashion business due to consumers’ increasing awareness of environment. When a fashion company aims to promote sustainability, the main linkage is to develop a sustainable supply chain. This paper contributes to current knowledge of sustainable supply chain in the textile and clothing industry. We first depict the structure of sustainable fashion supply chain including eco-material preparation, sustainable manufacturing, green distribution, green retailing, and ethical consumers based on the extant literature. We study the case of the Swedish fast fashion company, H&M, which has constructed its sustainable supply chain in developing eco-materials, providing safety training, monitoring sustainable manufacturing, reducing carbon emission in distribution, and promoting eco-fashion. Moreover, based on the secondary data and analysis, we learn the lessons of H&M’s sustainable fashion supply chain from the country perspective: (1 the H&M’s sourcing managers may be more likely to select suppliers in the countries with lower degrees of human wellbeing; (2 the H&M’s supply chain manager may set a higher level of inventory in a country with a higher human wellbeing; and (3 the H&M CEO may consider the degrees of human wellbeing and economic wellbeing, instead of environmental wellbeing when launching the online shopping channel in a specific country.

  16. Comparison of ionospheric F2 peak parameters foF2 and hmF2 with IRI2001 at Hainan

    Science.gov (United States)

    Wang, X.; Shi, J. K.; Wang, G. J.; Gong, Y.

    2009-06-01

    Monthly median values of foF2, hmF2 and M(3000)F2 parameters, with quarter-hourly time interval resolution for the diurnal variation, obtained with DPS4 digisonde at Hainan (19.5°N, 109.1°E; Geomagnetic coordinates: 178.95°E, 8.1°N) are used to investigate the low-latitude ionospheric variations and comparisons with the International Reference Ionosphere (IRI) model predictions. The data used for the present study covers the period from February 2002 to April 2007, which is characterized by a wide range of solar activity, ranging from high solar activity (2002) to low solar activity (2007). The results show that (1) Generally, IRI predictions follow well the diurnal and seasonal variation patterns of the experimental values of foF2, especially in the summer of 2002. However, there are systematic deviation between experimental values and IRI predictions with either CCIR or URSI coefficients. Generally IRI model greatly underestimate the values of foF2 from about noon to sunrise of next day, especially in the afternoon, and slightly overestimate them from sunrise to about noon. It seems that there are bigger deviations between IRI Model predictions and the experimental observations for the moderate solar activity. (2) Generally the IRI-predicted hmF2 values using CCIR M(3000)F2 option shows a poor agreement with the experimental results, but there is a relatively good agreement in summer at low solar activity. The deviation between the IRI-predicted hmF2 using CCIR M(3000)F2 and observed hmF2 is bigger from noon to sunset and around sunrise especially at high solar activity. The occurrence time of hmF2 peak (about 1200 LT) of the IRI model predictions is earlier than that of observations (around 1500 LT). The agreement between the IRI hmF2 obtained with the measured M(3000)F2 and the observed hmF2 is very good except that IRI overestimates slightly hmF2 in the daytime in summer at high solar activity and underestimates it in the nighttime with lower values near

  17. Expression of kenaf mitochondrial chimeric genes HM184 causes male sterility in transgenic tobacco plants.

    Science.gov (United States)

    Zhao, Yanhong; Liao, Xiaofang; Huang, Zhipeng; Chen, Peng; Zhou, Bujin; Liu, Dongmei; Kong, Xiangjun; Zhou, Ruiyang

    2015-08-01

    Chimeric genes resulting from the rearrangement of a mitochondrial genome were generally thought to be a causal factor in the occurrence of cytoplasmic male sterility (CMS). In the study, earlier we reported that identifying a 47 bp deletion at 3'- flanking of atp9 that was linked to male sterile cytoplasm in kenaf. The truncated fragment was fused with atp9, a mitochondrial transit signal (MTS) and/or GFP, comprised two chimeric genes MTS-HM184-GFP and MTS-HM184. The plant expression vector pBI121 containing chimeric genes were then introduced to tobacco plants by Agrobacterium-mediated T-DNA transformation. The result showed that certain transgenic plants were male sterility or semi-sterility, while some were not. The expression analysis further demonstrated that higher level of expression were showed in the sterility plants, while no expression or less expression in fertility plants, the levels of expression of semi-sterility were in between. And the sterile plant (containing MTS-HM184-GFP) had abnormal anther produced malformed/shriveled pollen grains stained negative that failed to germinate (0%), the corresponding fruits was shrunken, the semi-sterile plants having normal anther shape produced about 10-50% normal pollen grains, the corresponding fruits were not full, and the germination rate was 58%. Meanwhile these transgenic plants which altered on fertility were further analyzed in phenotype. As a result, the metamorphosis leaves were observed in the seedling stage, the plant height of transgenic plants was shorter than wild type. The growth duration of transgenic tobacco was delayed 30-45 days compared to the wild type. The copy numbers of target genes of transgenic tobacco were analyzed using the real-time quantitative method. The results showed that these transgenic plants targeting-expression in mitochondrial containing MTS-HM184-GFP had 1 copy and 2 copies, the other two plants containing MTS-HM184 both had 3 copies, but 0 copy in wild type. In

  18. HM{sup +}–RG complexes (M = group 2 metal; RG = rare gas): Physical vs. chemical interactions

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Joe P.; Dodson, Hannah; Wright, Timothy G., E-mail: Tim.Wright@nottingham.ac.uk [School of Chemistry, University of Nottingham, University Park, Nottingham NG7 2RD (United Kingdom); Breckenridge, W. H. [Department of Chemistry, University of Utah, Salt Lake City, Utah 84112 (United States)

    2015-04-21

    Previous work on the HM{sup +}–He complexes (M = Be–Ra) has been extended to the cases of the heavier rare gas atoms, HM{sup +}–RG (RG = Ne–Rn). Optimized geometries and harmonic vibrational frequencies have been calculated using MP2 theory and quadruple-ζ quality basis sets. Dissociation energies for the loss of the rare gas atom have been calculated at these optimized geometries using coupled cluster with single and double excitations and perturbative triples, CCSD(T)theory, extrapolating interaction energies to the basis set limit. Comparisons are made between the present data and the previously obtained helium results, as well as to those of the bare HM{sup +} molecules; furthermore, comparisons are made to the related M{sup +}–RG and M{sup 2+}–RG complexes. Partial atomic charge analyses have also been undertaken, and these used to test a simple charge-induced dipole model. Molecular orbital diagrams are presented together with contour plots of the natural orbitals from the quadratic configuration with single and double excitations (QCISD) density. The conclusion is that the majority of these complexes are physically bound, with very little sharing of electron density; however, for M = Be, and to a lesser extent M = Mg, some evidence for chemical effects is seen in HM{sup +}–RG complexes involving RG atoms with the higher atomic numbers.

  19. ST-HM not only cranes

    CERN Document Server

    Bertone, C

    2002-01-01

    This period of LEP dismantling and LHC installation is a real challenge for the ST-HM group. The group is now following several projects to cope with the diversity of requests. Although crane design and procurement still constitutes the majority of the workload, more and more of our time is nowadays dedicated to providing alternative handling solutions. In 2001/2002, our main studies concern cranes for LHC, industrial and shielded motorised doors, the upgrade/replacement of 32 lifts and mobile cranes. The years 2002/2003 will concern mainly the study of LHC handling systems such as trailers and heavy-duty tractors, specifically tailored containers and tools. In parallel, the monorail will be extended in the injection tunnel and CNGS tunnels and a new monorail system for TOF will be installed. Since the tunnel monorail infrastructure will be used for power feed and guidance purposes only, this requires that other transport systems be studied, such as forklift trucks, industrial and telescopic hoists.

  20. Interaction of HmC1q with leech microglial cells: involvement of C1qBP-related molecule in the induction of cell chemotaxis

    Directory of Open Access Journals (Sweden)

    Tahtouh Muriel

    2012-02-01

    Full Text Available Abstract Background In invertebrates, the medicinal leech is considered to be an interesting and appropriate model to study neuroimmune mechanisms. Indeed, this non-vertebrate animal can restore normal function of its central nervous system (CNS after injury. Microglia accumulation at the damage site has been shown to be required for axon sprouting and for efficient regeneration. We characterized HmC1q as a novel chemotactic factor for leech microglial cell recruitment. In mammals, a C1q-binding protein (C1qBP alias gC1qR, which interacts with the globular head of C1q, has been reported to participate in C1q-mediated chemotaxis of blood immune cells. In this study, we evaluated the chemotactic activities of a recombinant form of HmC1q and its interaction with a newly characterized leech C1qBP that acts as its potential ligand. Methods Recombinant HmC1q (rHmC1q was produced in the yeast Pichia pastoris. Chemotaxis assays were performed to investigate rHmC1q-dependent microglia migration. The involvement of a C1qBP-related molecule in this chemotaxis mechanism was assessed by flow cytometry and with affinity purification experiments. The cellular localization of C1qBP mRNA and protein in leech was investigated using immunohistochemistry and in situ hybridization techniques. Results rHmC1q-stimulated microglia migrate in a dose-dependent manner. This rHmC1q-induced chemotaxis was reduced when cells were preincubated with either anti-HmC1q or anti-human C1qBP antibodies. A C1qBP-related molecule was characterized in leech microglia. Conclusions A previous study showed that recruitment of microglia is observed after HmC1q release at the cut end of axons. Here, we demonstrate that rHmC1q-dependent chemotaxis might be driven via a HmC1q-binding protein located on the microglial cell surface. Taken together, these results highlight the importance of the interaction between C1q and C1qBP in microglial activation leading to nerve repair in the medicinal

  1. Interaction of HmC1q with leech microglial cells: involvement of C1qBP-related molecule in the induction of cell chemotaxis.

    Science.gov (United States)

    Tahtouh, Muriel; Garçon-Bocquet, Annelise; Croq, Françoise; Vizioli, Jacopo; Sautière, Pierre-Eric; Van Camp, Christelle; Salzet, Michel; Nagnan-le Meillour, Patricia; Pestel, Joël; Lefebvre, Christophe

    2012-02-22

    In invertebrates, the medicinal leech is considered to be an interesting and appropriate model to study neuroimmune mechanisms. Indeed, this non-vertebrate animal can restore normal function of its central nervous system (CNS) after injury. Microglia accumulation at the damage site has been shown to be required for axon sprouting and for efficient regeneration. We characterized HmC1q as a novel chemotactic factor for leech microglial cell recruitment. In mammals, a C1q-binding protein (C1qBP alias gC1qR), which interacts with the globular head of C1q, has been reported to participate in C1q-mediated chemotaxis of blood immune cells. In this study, we evaluated the chemotactic activities of a recombinant form of HmC1q and its interaction with a newly characterized leech C1qBP that acts as its potential ligand. Recombinant HmC1q (rHmC1q) was produced in the yeast Pichia pastoris. Chemotaxis assays were performed to investigate rHmC1q-dependent microglia migration. The involvement of a C1qBP-related molecule in this chemotaxis mechanism was assessed by flow cytometry and with affinity purification experiments. The cellular localization of C1qBP mRNA and protein in leech was investigated using immunohistochemistry and in situ hybridization techniques. rHmC1q-stimulated microglia migrate in a dose-dependent manner. This rHmC1q-induced chemotaxis was reduced when cells were preincubated with either anti-HmC1q or anti-human C1qBP antibodies. A C1qBP-related molecule was characterized in leech microglia. A previous study showed that recruitment of microglia is observed after HmC1q release at the cut end of axons. Here, we demonstrate that rHmC1q-dependent chemotaxis might be driven via a HmC1q-binding protein located on the microglial cell surface. Taken together, these results highlight the importance of the interaction between C1q and C1qBP in microglial activation leading to nerve repair in the medicinal leech.

  2. Comparison of Tc-99m HM-PAO SPECT brain scan and x-ray CT in the detection of brain metastases

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.M.; Sadek, S.; Sahwell, A.; Kubasek, H.; El-Sayed, M.; Ziada, G.; Mobarak, L.; Al-Huda, F.; Omar, Y.T.

    1986-01-01

    Tc-99m HM-PAO imaging was compared with x-ray CT in 14 patients with known or suspected brain metastases. Both studies were done within 3 days of each other. Static and single photon emission CT (SPECT) images were acquired after intravenous injection of 13 mCi of Tc-99m HM-PAO. All 14 patients underwent static and SPECT Tc-99m HM-PAO imaging and x-ray CT. Studies were positive in 7, 12, and 10 patients, respectively, by static, SPECT, and x-ray CT imaging, and negative in 7, 2, and 2. The number of lesions identified was 0 (static imaging), 32 (SPECT), and 26(x-ray CT). There were no ''suspicious'' studies by any modality. This study indicates that Tc-99m HM-PAO SPECT cerebral blood flow imaging is more sensitive than x-ray CT for detecting brain metastases, that biplane imaging is not sensitive and SPECT is essential, and that for Tc-99m HM-PAO SPECT brain imaging to regain its importance with respect to x-ray CT, acquisition time must be 10 minutes or less and determination of percentage brain uptake of the injected dose, and of regional distribution, is necessary

  3. Clinical applications of brain perfusion imaging with 99mTc-HM-PAO

    International Nuclear Information System (INIS)

    Lin Xiangtong

    1989-01-01

    200 patients with central nervous system diseases were studied with 99m Tc-HM-PAO and SPECT, including Parkinson's disease (PD) 47, Vascular headache 69, CVD 34, Epilepsy 26, Head truma 10, Brain tumor 5 and other 9 cases. Part of them have been compared with the results of MRI, X-CT and EEG. The positivity of SPECT in PD is 61.7% with decrease perfusion in local area of cerebram and basal ganglia and only 4 cases had lower perfusion in cerebellum; in headache is 46.4%, showing variable perfusion patterns; in CVD is 79.4% with decrease perfusion, luxury perfusion and the phenomenon of 'diaschsis'. In epilepsy, the abnormal foci mostly localize in temporal lobe and have close relation to the results of EEG. In brain tumor it also denotes decreased uptake of tracer. The clinicl singnificance of brain perfusion imaging with 99m Tc-HM-PAO was discussed

  4. SPET with sup 99m Tc-HM PAO in the study of classic migraine. La SPET con sup 99m Tc-HM PAO nello studio dell'emicrania classica

    Energy Technology Data Exchange (ETDEWEB)

    Stiglich, F; Bonomo, F; Barbonetti, C; Di Lorenzo, I; Bottinelli, G [Ospedale Civile, Sondrio (Italy). Div. di Medicina Nucleare e Radioterapia; Tomaiolo, S [Ospedale Civile, Sondrio (Italy). Div. di Neurologia; Campani, R; Bottinelli, O [Pavia Univ. (Italy). Ist. di Radiologia

    1991-01-01

    Five patients presenting with migraine attacks underwent Electroencephalography (EEC), Computed Tomography (CT) and Single Photon Emission Tomography (SPET) with {sup 99m}Tc-HM PAO. EEG qand SPET were subsequently repeated in the intercritical period. We observed that two patients only showed non-specific abnormalities in EEG; scans were in all patients; all subjects exhibited diffuse cortical hypoperfusion. A strong correlation was always found between clinical presentation and hemispheric impairment. One patient exhibited asymmetrical perfusion between cerebellum hemispheres; intercritical SPET showed homogeneous distrubution of the radio-tracer in 4 patients. In the last one minimal residual hypoperfusion was observed, although less marked than in the acute phase. Therefore SPET with {sup 99m}Tc-HM PAO can be reasonably employed as the examination of choice when a migrain attack is clinically suspected, because of its reproducibility and reliability. It can be easily performed in every nuclear medical center supplied with modern tomographic cameras.

  5. The class characteristic mark of the H&M Mul-T-Lock picking tool in toolmarks examination.

    Science.gov (United States)

    Volkov, Nikolai; Finkelstein, Nir; Novoselsky, Yehuda; Tsach, Tsadok

    2014-07-01

    Mul-T-Lock is a high security lock cylinder distinguished by the use of a telescoping "pin-in-pin"-tumbler design. Picking the Mul-T-Lock cylinder with a traditional picking tool is highly complicated because it can get stuck between the inner and outer pins. The H&M Mul-T-Lock picking tool was designed to overcome this problem and facilitate the picking of the "pin-in-pin" cylinder. The purpose of this research is to determine whether H&M Mul-T-Lock picking tool leaves class characteristic mark and whether it can be distinguished from traditional picking tools marks and from regular key marks. It also describes and determines the class characteristic mark left on telescopic pins, its origin, recurrence, and its benefit to the toolmarks examiner. When receiving a Mul-T-Lock from a crime scene, a toolmarks examiner can quickly determine whether or not it was picked by an H&M Mul-T-Lock picking tool by noticing the class characteristic mark which this typical tool leaves. © 2014 American Academy of Forensic Sciences.

  6. Special applications of [sup 99m]Tc-HM-PAO SPECT in the evaluation of cerebral hemodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Shigeki; Kageyama, Yuhsuke (Chiba Emergency Medical Center (Japan)); Namba, Hiroki (and others)

    1991-12-01

    [sup 99m]Tc-HM-PAO has been widely used as a brain-perfusion tracer. It is known that this lipophilic tracer crosses the blood-brain barrier with a high-pass extraction fraction, is deposited in the brain proportional to the cerebral blood flow, and shows a nearly constant maintenance of the regional distribution over several hours. Taking advantage of these characteristics of the tracer, we evaluated changes in the cerebral blood flow before and after recanalization therapy in the acute stage of stroke. Recent advances in catheterization technique have made it possible to introduce a catheter superselectively into smaller cerebral vessels, such as anterior, middle, and posterior cerebral arteries and external carotid artery branches. We ourselves evaluated the areas and concentrations of anti-cancer agents by injecting HM-PAO through the microcatheter used for superselective intra-arterial chemotherapy. We also visualized the areas supplied by the grafted vessels after bypass surgery for ischemic cerebrovascular diseases by the superselective infusion of HM-PAO. We found these techniques to be useful in clinical neurosurgery. (author).

  7. Use of technetium-99m-HM-PAO in the assessment of patients with dementia and other neuropsychiatric conditions

    International Nuclear Information System (INIS)

    Smith, F.W.; Besson, J.A.; Gemmell, H.G.; Sharp, P.F.

    1988-01-01

    One hundred fourteen patients suffering from neuropsychiatric conditions have been studied using 99mTc-labeled hexamethylpropyleneamine oxime (HM-PAO) and single photon emission computed tomography (SPECT). Ninety-one patients had a firm clinical diagnosis while 23 were examined without knowledge of the clinical diagnosis. Of the 91 patients, 51 were suffering from dementia, 25 multi-infarct type and 26 Alzheimer's disease. In 19 of the Alzheimer's patients, a characteristic pattern of decreased perfusion in the parieto-occipital regions was demonstrated while those with multi-infarct type showed varying degrees of irregular uptake in the cerebral cortex. These appearances are similar to those shown with positron emission tomography (PET) and we believe that HM-PAO will provide a widely available method for identifying patients with Alzheimer's disease. Twenty-nine patients were suffering from diseases involving the basal ganglia. Fifteen patients with Parkinson's disease showed no significant abnormality in basal ganglia uptake, while 7 or 8 patients with Huntington's disease who had full examinations showed decreased uptake in the caudate nuclei. Similarly, four of six patients with other basal ganglia diseases showed impaired uptake by basal ganglia, and it is concluded that HM-PAO may be useful for the diagnosis and management of this type of patient. Twenty-three patients received HM-PAO imaging as part of their diagnostic work-up; in 19 of them, detailed follow-up was obtained, which indicated that in 7 cases the result of the HM-PAO scan altered the clinical diagnosis and in 9 cases resulted in a change in management. In the remaining 13 cases, the study was found to be helpful in confirming the diagnosis

  8. Contributions for Repositioning a Regional Strategy for Healthy Municipalities, Cities and Communities (HM&C): Results of a Pan-American Survey

    Science.gov (United States)

    Rice, Marilyn; Vizzotti, Carlos; Frassia, Romina; Vizzotti, Pablo; Akerman, Marco

    2010-01-01

    This article presents the results of the 1st Regional Survey of Healthy Municipalities, Cities and Communities (HM&C) carried out in 2008 by the Pan American Health Organization (PAHO) and ISALUD University of Argentina. It discusses the responses obtained from 12 countries in the Americas Region. Key informants in Argentina, Brazil, Chile, Colombia, Costa Rica, Cuba, Mexico, Paraguay, Peru, and Uruguay were selected and encouraged to answer the survey, while informants from Canada and Honduras answered voluntarily and were included in this analysis. The discussion of the results of the Survey provides insight into the current status of HM&C in the Region and suggests key topics for repositioning the Regional strategy relative to: (1) the conceptual identity and tools for HM&C; (2) challenging areas in the implementation process (scale, legal framework, and development of capacities); (3) related strategies and participatory processes such as the ways citizen empowerment in governance is supported; (4) the need to monitor and assess the impact of the HM&C strategy on the health and quality of life of the populations involved; and (5) the need for developing a strategic research and training agenda. The analysis and discussion of these results aims to provide useful input for repositioning the strategy in the Region and contributing to the emergence of a second generation of concepts and tools capable of meeting the developing priorities and needs currently faced by the HM&C strategy. PMID:20532989

  9. Benchmark on hydrogen distribution in a containment based on the OECD-NEA THAI HM-2 experiment

    International Nuclear Information System (INIS)

    Schwarz, S.; Fischer, K.; Bentaib, A.

    2009-01-01

    Within the course of a hypothetical severe accident in a nuclear power plant, hydrogen can be generated in the primary circuit and released into the containment. Considering the possibility of a deflagration, the simulation of the hydrogen distribution in the containment by computer codes is of major importance. In order to create a data base for code validation, several distribution experiments using helium and hydrogen have been performed in the German THAI (Thermal-Hydraulics, Hydrogen, Aerosols, Iodine) facility. They started with the ISP-47 test TH13 and were followed by the HM (Hydrogen-Helium Material Scaling Tests) series. The objectives of the HM Tests are to confirm the transferability of existing helium distribution test data to hydrogen distribution problems, to understand the processes that lead to the formation and dissolution of a light cloud stratification. The test HM-2 was chosen for a code benchmark. During the first phase of test HM-2 a light gas cloud consisting of hydrogen and nitrogen was established in the upper half of the facility. In the second phase steam was injected at a lower position inducing a rising steam - nitrogen plume. The plume did not break through the cloud, because its density was higher than the density of the cloud. Therefore the cloud was gradually dissolved from its bottom. Eleven organisations performed 'blind' calculations to the HM-2 experiment. The lumped parameter (LP) codes ASTEC, COCOSYS and MELCOR and the CFD codes FLUENT, GASFLOW and GOTHIC were used. The main phenomena were natural convection, interaction between the rising plume and the light gas cloud, steam condensation on walls, fog behaviour and the heat up of the walls. The experimental data of the first phase had been published and the atmospheric stratification was simulated reasonably well. The data from the second phase stayed concealed until the simulated results were submitted. The thermal-hydraulic phenomena were predicted well by several LP- and

  10. Clinical applications of brain perfusion imaging with sup 99m Tc-HM-PAO

    Energy Technology Data Exchange (ETDEWEB)

    Xiangtong, Lin [Shanghai Medical Univ. (China). Huashan Hospital; and others

    1989-11-01

    200 patients with central nervous system diseases were studied with {sup 99m}Tc-HM-PAO and SPECT, including Parkinson's disease (PD) 47, Vascular headache 69, CVD 34, Epilepsy 26, Head truma 10, Brain tumor 5 and other 9 cases. Part of them have been compared with the results of MRI, X-CT and EEG. The positivity of SPECT in PD is 61.7% with decrease perfusion in local area of cerebram and basal ganglia and only 4 cases had lower perfusion in cerebellum; in headache is 46.4%, showing variable perfusion patterns; in CVD is 79.4% with decrease perfusion, luxury perfusion and the phenomenon of 'diaschsis'. In epilepsy, the abnormal foci mostly localize in temporal lobe and have close relation to the results of EEG. In brain tumor it also denotes decreased uptake of tracer. The clinicl singnificance of brain perfusion imaging with {sup 99m}Tc-HM-PAO was discussed.

  11. ULTRACAM photometry of the ultracompact binaries V407 Vul and HM Cnc

    NARCIS (Netherlands)

    Barros, S.C.C.; Marsh, T.R.; Dhillon, V.S.; Groot, P.J.; Littlefair, S.; Nelemans, G.A.; Roelofs, G.H.A.; Steeghs, D.; Wheatley, P.J.

    2007-01-01

    V407 Vul (RXJ1914.4+2456) and HM Cnc (RXJ0806.3+1527) are X-ray emitting stars with X-ray light curves that are 100 per cent modulated on periods of 569 and 321 s, respectively. These periods are thought possibly to represent the orbital periods of close pairs of white dwarfs. In this paper we

  12. HM-PAO-SPECT in complicated migraine. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Gruenwald, F.; Ruhlmann, J.; Biersack, H.J.; Durwen, H.; Penin, H.

    1988-10-01

    Three HM-PAO-SPECT investigations have been performed in a female patient with a complicated migraine. 2.5 hours after an attack with right-sided numbness and atonic hemiparesis, at the left side a reduced blood flow was seen parietotemporally and in the subcortical structures. The cerebellum showed crossed diaschisis. During a symptom-free interval the SPECT showed a slightly increased parietotemporal blood blow and a reduced right temporooccipital blood flow. During a seizure with left-sided facial spasm, unsystematic clonic movements in all extremities and a following left-sided hemiparesis, the uptake in the visual cortex was increased by 60%. In the right frontotemporal and left temporal region a slightly increased accumulation was found.

  13. Non-Invasive Mapping of Intraventricular Flow Patterns in Patients Treated with Left Ventricular Assist Devices

    Science.gov (United States)

    Miramontes, Marissa; Rossini, Lorenzo; Braun, Oscar; Brambatti, Michela; Almeida, Shone; Mizeracki, Adam; Martinez-Legazpi, Pablo; Benito, Yolanda; Bermejo, Javier; Kahn, Andrew; Adler, Eric; Del Álamo, Juan C.

    2017-11-01

    In heart failure patients, left ventricular (LV) assist devices (LVADs) decrease mortality and improve quality of life. We hypothesize echo color Doppler velocimetry (echo-CDV), an echocardiographic flow mapping modality, can non-invasively characterize the effect of LVAD support, optimize the device, thereby decreasing the stoke rate present in these patients. We used echo-CDV to image LV flow at baseline LVAD speed and during a ramp test in LVAD patients (Heartmate II, N =10). We tracked diastolic vortices and mapped blood stasis and cumulative shear. Compared to dilated cardiomyopathy (DCM) patients without LVADs, the flow had a less prominent diastolic vortex ring, and transited directly from mitral valve to cannula. Residence time and shear were significantly lower compared to healthy controls and DCMs. Aortic regurgitation and a large LV vortex presence or a direct mitral jet towards the cannula affected blood stasis region location and size. Flow patterns, residence time and shear depended on LV geometry, valve function and LVAD speed in a patient specific manner. This new methodology could be used with standard echo, hemodynamics and clinical information to find the flow optimizing LAVD setting minimizing stasis for each patient.

  14. Comparison of Tc-99m HM-PAO and I-123 IMP cerebral SPECT images in Alzheimer's disease and multi-infarct dementia

    Energy Technology Data Exchange (ETDEWEB)

    Gemmell, H G; Sharp, P F; Besson, J A.O.; Ebmeier, K P; Smith, F W

    1988-10-01

    SPECT images of the brain can be obtained using either /sup 123/I labelled amines or /sup 99m/Tc-hexamethylpropyleneamineoxime (HM-PAO). Both materials produce images which are blood flow dominated and so appear similar in normal subjects, although the respective mechanisms of uptake are not yet finally established. It seems likely, however, that the different mechanisms of uptake are responsible for recent reports of some differences seen in images obtained with the two types of agent in patients with cerebral pathology, mainly cerebrovascular disease. In this study, 12 demented patients, 6 with dementia of the Alzheimer type (DAT) and 6 with multi infarct dementia (MID), were imaged with /sup 123/I-isopropylamphetamine (IMP) and /sup 99m/Tc-HM-PAO and the images compared. Significantly more lesions were seen with IMP than HM-PAO (P < 0.02); out of a possible 120 sites, 41 lesions were seen with IMP compared to 28 with HM-PAO, 23 being seen with both agents. However, it is concluded that either agent can be used for the differential diagnosis of dementia, a task for which the new cerebral blood flow agents seem well suited.

  15. Array-based assay detects genome-wide 5-mC and 5-hmC in the brains of humans, non-human primates, and mice.

    Science.gov (United States)

    Chopra, Pankaj; Papale, Ligia A; White, Andrew T J; Hatch, Andrea; Brown, Ryan M; Garthwaite, Mark A; Roseboom, Patrick H; Golos, Thaddeus G; Warren, Stephen T; Alisch, Reid S

    2014-02-13

    Methylation on the fifth position of cytosine (5-mC) is an essential epigenetic mark that is linked to both normal neurodevelopment and neurological diseases. The recent identification of another modified form of cytosine, 5-hydroxymethylcytosine (5-hmC), in both stem cells and post-mitotic neurons, raises new questions as to the role of this base in mediating epigenetic effects. Genomic studies of these marks using model systems are limited, particularly with array-based tools, because the standard method of detecting DNA methylation cannot distinguish between 5-mC and 5-hmC and most methods have been developed to only survey the human genome. We show that non-human data generated using the optimization of a widely used human DNA methylation array, designed only to detect 5-mC, reproducibly distinguishes tissue types within and between chimpanzee, rhesus, and mouse, with correlations near the human DNA level (R(2) > 0.99). Genome-wide methylation analysis, using this approach, reveals 6,102 differentially methylated loci between rhesus placental and fetal tissues with pathways analysis significantly overrepresented for developmental processes. Restricting the analysis to oncogenes and tumor suppressor genes finds 76 differentially methylated loci, suggesting that rhesus placental tissue carries a cancer epigenetic signature. Similarly, adapting the assay to detect 5-hmC finds highly reproducible 5-hmC levels within human, rhesus, and mouse brain tissue that is species-specific with a hierarchical abundance among the three species (human > rhesus > mouse). Annotation of 5-hmC with respect to gene structure reveals a significant prevalence in the 3'UTR and an association with chromatin-related ontological terms, suggesting an epigenetic feedback loop mechanism for 5-hmC. Together, these data show that this array-based methylation assay is generalizable to all mammals for the detection of both 5-mC and 5-hmC, greatly improving the utility of mammalian model systems

  16. Assessing the Influence of Fashion Clothing Advertising on Women's Consumer Behaviour in Finland; a case study of H&M

    OpenAIRE

    Hamed Abu Adab, Sari

    2012-01-01

    This study will provide a framework for analysing the current advertising and marketing patterns in women’s consumer behaviour in Finland. Swedish clothing retailer Hennes&Mauritz (H&M) was chosen as a case study since it is considered to be well-known in Finland; in 2010 average sales were astonishingly around 243million euros (H&M 2012). As this research is considered to be a broad topic, this study will focus on women in Finland aged 16-35 and above. This study will use various research m...

  17. Causes of the cracks in the pipeline made of the 15HM steel

    Directory of Open Access Journals (Sweden)

    Słania J.

    2017-03-01

    Full Text Available Issues referring to cracks in the pipelines made of the 15HM steel are described. Metallographic specimen of welded joints are provided. The results of impact strength tests, hardness tests and static tensile tests are given. Tests results as well as direct and indirect causes of the pipeline cracks are shown.

  18. Extraction of [99mTc]-d,l-HM-PAO across the blood-brain barrier

    DEFF Research Database (Denmark)

    Andersen, A R; Friberg, H; Knudsen, K B

    1988-01-01

    The initial extraction (E) across the blood-brain barrier (BBB) of [99mTc]-d,l-HM-PAO after intracarotid injection was measured in 14 Wistar rats and 6 patients using the double indicator, single injection method with Na-24 as the cotracer. In both series, cerebral blood flow (CBF) was measured...... was increased from 20 to 120 microliters, while using a 120 microliters bolus containing 10% albumin resulted in a decrease in E. This suggests that HM-PAO binding to albumin is not totally and rapidly reversible during a single passage through brain capillaries and that binding to blood elements may reduce...... the apparent extraction across brain capillaries. In patients using a bolus of 1 ml saline, E decreased linearly with increasing CBF (r = -0.81, p less than 0.001). For a CBF of 0.59 ml/g/min and an average apparent E of 0.72, an apparent PS product of 0.76 ml/g/min was calculated.(ABSTRACT TRUNCATED AT 250...

  19. Epigenomic Co-localization and Co-evolution Reveal a Key Role for 5hmC as a Communication Hub in the Chromatin Network of ESCs

    Directory of Open Access Journals (Sweden)

    David Juan

    2016-02-01

    Full Text Available Summary: Epigenetic communication through histone and cytosine modifications is essential for gene regulation and cell identity. Here, we propose a framework that is based on a chromatin communication model to get insight on the function of epigenetic modifications in ESCs. The epigenetic communication network was inferred from genome-wide location data plus extensive manual annotation. Notably, we found that 5-hydroxymethylcytosine (5hmC is the most-influential hub of this network, connecting DNA demethylation to nucleosome remodeling complexes and to key transcription factors of pluripotency. Moreover, an evolutionary analysis revealed a central role of 5hmC in the co-evolution of chromatin-related proteins. Further analysis of regions where 5hmC co-localizes with specific interactors shows that each interaction points to chromatin remodeling, stemness, differentiation, or metabolism. Our results highlight the importance of cytosine modifications in the epigenetic communication of ESCs. : 5-hydroxymethylcytosine (5hmC plays a key role in the epigenomic communication network of embryonic stem cells. Juan et al. build a communication network based in co-localization of epigenomic data and literature. The analysis of the network and its components reveals that proteins reading and editing 5hmC co-evolve and serve as links between diverse molecular processes.

  20. Die etiek van HM Kuitert na aanleiding van sy boek Suicide - wat is ...

    African Journals Online (AJOL)

    The ethics of HM Kuitert according to his book entitled. Suicide - wat is er tegen? Selfdoding in moreel perspektief. According to several publications Kuitert is criticised as a humanist. This paper tests his view on suicide to this accusation. It is found that Kuitert accepts teleology and solidarity as norms for his ethics and uses ...

  1. A modified Glenn shunt reduces right ventricular stroke work during left ventricular assist device therapy.

    Science.gov (United States)

    Schiller, Petter; Vikholm, Per; Hellgren, Laila

    2016-03-01

    Right ventricular (RV) failure is a major cause of morbidity and mortality after left ventricular assist device (LVAD) placement and remains hard to predict. We hypothesized that partial surgical exclusion of the RV with a modified Glenn shunt during LVAD treatment would reduce RV stroke work. An LVAD was implanted in eight pigs and a modified Glenn shunt was constructed. A conductance pressure-volume catheter was placed in the right ventricle through the apex. Haemodynamic data and pressure-volume loops were obtained at the following time periods: (i) baseline, (ii) open shunt, (iii) LVAD with closed shunt and (iii) LVAD and open shunt. During LVAD therapy, the right atrial (RA) pressure increased from 9 mmHg (9-9) to 15 mmHg (12-15), P = 0.01. RV stroke volume increased from 30 ml (29-40) to 51 ml (42-53), P work increased to 708 mmHg ml (654-1193) from 535 mmHg ml (424-717), P = 0.04, compared with baseline. During LVAD therapy in combination with a Glenn shunt, the RA pressure decreased from 15 mmHg (12-15) to 10 mmHg (7-11) when compared with LVAD therapy only, P = 0.01. A decrease in RV stroke work from 708 mmHg ml (654-1193) to 465 mmHg ml (366-711), P = 0.04, was seen when the LVAD was combined with a shunt, not significantly different from the baseline value (535 mmHg ml). The developed pressure in the right ventricle decreased from 29 mmHg (26-32) to 21 mmHg (20-24), P work during the use of the shunt with LVAD treatment. A modified Glenn shunt reduced RV volumes, RV stroke work and RA pressure during LVAD therapy in an experimental model of heart failure in pigs. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. The successful implantation of continuous-flow left ventricular assist device as a destination therapy in Korea: echocardiographic assessment.

    Science.gov (United States)

    Lee, Ga Yeon; Park, Sung-Ji; Kim, Sujin; Choi, Namgyung; Jeong, Dong Seop; Jeon, Eun-Seok; Lee, Young Tak

    2014-01-01

    Left ventricular assist device (LVAD) is a good treatment option for the patients ineligible for cardiac transplantation. Several studies have demonstrated that a ventricular assist device improves the quality of life and prognosis of the patients with end-stage heart failure. A 75-yr-old man debilitated with New York Heart Association (NYHA) functional class III-IV due to severe left ventricular systolic dysfunction received LVAD implantation as a destination therapy. The patient was discharged with improved functional status (NYHA functional class II) after appropriate cardiac rehabilitation and education about how to manage the device and potential emergency situations. This is the first case of successful continuous-flow LVAD implantation as a destination therapy in Korea.

  4. Successful Implantation of a Left Ventricular Assist Device in a Patient with Heparin-Induced Thrombocytopenia and Thrombosis

    Science.gov (United States)

    Garland, Cassandra; Somogyi, David

    2014-01-01

    Abstract: We report the case of a 27-year-old woman with signs of heparin-induced thrombocytopenia and thrombosis (HITT) and left heart failure presenting for urgent implantation of a left ventricular assist device (LVAD). HITT can occur in 4.2–6.1% of patients with LVADs. If the patient remains hemodynamically stable, implantation can be delayed for several months until the heparin/PF-4 antibodies decline allowing the use of heparin on cardiopulmonary bypass, However, in most cases related to cardiogenic shock, surgery cannot be delayed. We present the case of a patient who underwent implantation of a HeartMate II LVAD and discuss management strategy using bivalirudin during cardiopulmonary bypass. PMID:25208434

  5. Evaluation of 99mTc-HM-PAO thigh accumulation in patients with cerebro-vascular disease

    International Nuclear Information System (INIS)

    Nishigaki, Hiroshi; Adachi, Itaru; Komori, Tsuyoshi; Tatsu, Yoshimitsu; Hisada, Youichi; Sueyoshi, Kouzou; Narabayashi, Isamu

    1993-01-01

    Technetium-99m d,l-hexamethyl-propyleneamine oxime ( 99m Tc-HM-PAO) cerebral SPECT and whole body scintigraphy (WBS) were performed in 5 patients without cerebro-vascular disease (CVD) (Group 1), 31 patients with CVD but not hemiparesis (Group 2) and 18 patients with CVD and hemiparesis (Group 3). Four ROIs were drawn manually around the whole body (WB), brain (Br), right and left thigh (Th). We calculated some ratios: the total counts in the brain over the total counts in the whole body (Br/WB), the total counts in the thigh over the total counts in the whole body (Th/WB) and the mean counts in the thigh over the mean counts in the brain (Th/Br). The Br/WB was 6.9±1.8%, rt-Th/WB was 4.9±2.1%, lt-Th/WB was 5.1±1.3% and Th/Br was 0.46±0.17 in group 1. Whole body scintigraphies in group 1 revealed clear and similar images between right and left thigh. The Br/WB was 6.7±1.4%, Th/WB of paretic side was 4.6±1.0%, Th/WB of non-paretic side was 5.8±1.2% and Th/Br was 0.47±0.18 in group 3. The Th/WB in non paretic side was significantly higher than that in paretic side (p 99m Tc-HM-PAO. It was possible that we evaluated not only cerebral perfusion but also muscle atrophy and/or perfusion in patients with CVD using 99m Tc-HM-PAO. (author)

  6. Improved regional-scale groundwater representation by the coupling of the mesoscale Hydrologic Model (mHM v5.7) to the groundwater model OpenGeoSys (OGS)

    Science.gov (United States)

    Jing, Miao; Heße, Falk; Kumar, Rohini; Wang, Wenqing; Fischer, Thomas; Walther, Marc; Zink, Matthias; Zech, Alraune; Samaniego, Luis; Kolditz, Olaf; Attinger, Sabine

    2018-06-01

    Most large-scale hydrologic models fall short in reproducing groundwater head dynamics and simulating transport process due to their oversimplified representation of groundwater flow. In this study, we aim to extend the applicability of the mesoscale Hydrologic Model (mHM v5.7) to subsurface hydrology by coupling it with the porous media simulator OpenGeoSys (OGS). The two models are one-way coupled through model interfaces GIS2FEM and RIV2FEM, by which the grid-based fluxes of groundwater recharge and the river-groundwater exchange generated by mHM are converted to fixed-flux boundary conditions of the groundwater model OGS. Specifically, the grid-based vertical reservoirs in mHM are completely preserved for the estimation of land-surface fluxes, while OGS acts as a plug-in to the original mHM modeling framework for groundwater flow and transport modeling. The applicability of the coupled model (mHM-OGS v1.0) is evaluated by a case study in the central European mesoscale river basin - Nägelstedt. Different time steps, i.e., daily in mHM and monthly in OGS, are used to account for fast surface flow and slow groundwater flow. Model calibration is conducted following a two-step procedure using discharge for mHM and long-term mean of groundwater head measurements for OGS. Based on the model summary statistics, namely the Nash-Sutcliffe model efficiency (NSE), the mean absolute error (MAE), and the interquartile range error (QRE), the coupled model is able to satisfactorily represent the dynamics of discharge and groundwater heads at several locations across the study basin. Our exemplary calculations show that the one-way coupled model can take advantage of the spatially explicit modeling capabilities of surface and groundwater hydrologic models and provide an adequate representation of the spatiotemporal behaviors of groundwater storage and heads, thus making it a valuable tool for addressing water resources and management problems.

  7. Radiolabelling of sperm cells with 99mTc-HM-PAO

    International Nuclear Information System (INIS)

    Balogh, L.; Szasz, F.; Janoki, Gy.; Zoldag, L.; Huszenicza, Gy.

    1992-01-01

    The study of the influence of labelling volume on the labelling efficiency showed decreased yield when the volume was increased. The survival rate was unchanged over 0.5 ml of reaction volume. During labelling procedure only a few cells (6%) survived in the incubation volume was less than 0.4 ml. Changing the incubation time the radiolabelling yield increased for 10 minutes, and thereafter practically did not change. The optimum conditions of sperm labelling yielded a high labelling efficiency (70-80%) and survival rate (50-60%). The 99m Tc-HM-PAO labelled sperm cells seem to be suitable to study the in vivo and in vitro sperm transport. (author) 14 refs.; 5 figs.; 2 tabs

  8. Perfil bioquímico do soro de frangos de corte alimentados com dieta suplementada com alfa-amilase de Cryptococcus flavus e Aspergillus niger HM2003 Biochemichal serum profile of broilers fed diets suplemented with alfa-amylase from Cryptococcus flavus and Aspergillus niger HM2003

    Directory of Open Access Journals (Sweden)

    Cibele Silva Minafra

    2010-12-01

    Full Text Available Avaliou-se o perfil bioquímico do soro de frangos de corte alimentados com a enzima α-amilase produzida por dois microrganismos. Produziram-se dois extratos, um com a-amilase obtida a partir de Cryptococcus flavus em meio de levedura comercial e outro com Aspergillus niger HM2003 em meio de proteína de soja e amido comercial, com atividade de 9,58 U/mL e 10,0 U/mL, respectivamente. Utilizaram-se 360 pintos de corte Cobb 500 de 1 dia de idade e com 49,72 ± 0,68 g de peso vivo inicial. As aves foram alojadas em baterias e foram criadas até os 21 dias de idade. Foram utilizados três dietas, cada uma com cinco repetições de 12 aves, em delineamento inteiramente casualizado. A primeira dieta (basal foi formulada sem adição de enzima e as outras duas receberam a suplementação de a-amilase produzida por cultivo de Cryptococcus flavus e Aspergillus niger HM2003. Dietas à base de milho e soja foram formuladas em duas fases: pré-inicial (1-7 dias e inicial (8-21 dias. Na fase pré-inicial, foram observados os seguintes valores médios para cálcio (6,90 e 5,99 mg/dL, proteína plasmática (2,0 e 2,50 g/dL e fosfatase alcalina (979,98 e 974,66 UI/L, respectivamente para Cryptococcus flavus e Aspergillus niger HM2003. A dieta acrescida de a-amilase obtida a partir de Aspergillus niger HM2003 determinou maior concentração sérica de fósforo. Na fase inicial, os resultados significativos relacionaram-se a potássio quando avaliadas dietas com adição de a-amilase pelas duas fontes. A incorporação das enzimas testadas não proporciona alterações metabólicas ou toxicidade nos animais.It was evaluated the biochemical serum profile of broilers fed rations supplemented with α-amylase produced by two microorganisms. Two extracts were produced, one was produced with a-amylase obtained from Cryptococcus flavus in a commercial yeast-based medium and the other with Aspergillus niger HM2003 produced in soybean protein and commercial starch medium

  9. 99mTc-ECD and 99mTc-HM-PAO SPECT in five patients with MELAS

    International Nuclear Information System (INIS)

    Katagiri, Shinako; Nishimaki, Hiroshi; Kitano, Masashi; Horiike, Shigeharu; Kan, Shinichi; Ishii, Katsumi; Matsubayashi, Takashi; Sakai, Fumihiko

    1998-01-01

    Cerebral perfusion was studied in five patients with mitochondrial encephalomyopathy with lactic acidosis and stroke-like episodes syndrome (MELAS), using single photon emission computed tomography (SPECT) with 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD) or 99m Tc-hexamethyl propyleneamine oxime ( 99m Tc-HM-PAO). In four cases, regional cerebral blood flow (rCBF) was evaluated by the method reported by Mastuda et al. Immediately after the stroke-like episodes, accumulation of the tracer was relatively increased in the temporooccipital lobe, and also increased rCBF was shown in the same area. However, the region showed decreased radioactivity at the chronic stage, and rCBF decreased also. These findings are consistent with positron emission tomography (PET) at the acute stage and autopsy. 99m Tc-ECD SPECT and 99m Tc-HM-PAO SPECT may be useful in the diagnosis and assessment of the progress of the MELAS. (author)

  10. Brain perfusion spect imaging with sup 99m Tc-HM-PAO in Parkinson's disease

    Energy Technology Data Exchange (ETDEWEB)

    Wenzhong, Song; Xiangtong, Lin [Shanghai Medical Univ. (China). Huashan Hospital

    1991-02-01

    Forty patients with Parkinson's disease were studied using {sup 99m}Tc-HM-PAO brain perfusion SPECT. 62.5% (25 cases) showed abnormal blood perfusion. Among them 55% showed local decreased blood perfusion of cerebral cortex, 22% showed asymmetric decreased blood perfusion in basal gaglia, 10% showed decreased uptake of tracer in cerebellum. The pathophysiologic basis of the abnormality of brain blood perfusion were briefly discussed.

  11. The Impact of Obesity on Patients Bridged to Transplantation with Continuous-Flow Left Ventricular Assist Devices

    Science.gov (United States)

    Clerkin, Kevin J.; Naka, Yoshifumi; Mancini, Donna M.; Colombo, Paolo C.; Topkara, Veli K.

    2017-01-01

    Objectives This study sought to determine if obese patients had worse post-LVAD implantation outcomes and if the implantation of an LVAD allowed for weight loss. Background Obesity is a risk factor for cardiovascular disease including heart failure. Obese heart failure patients have better outcomes than those with normal weight; however obese patients have worse outcomes following heart transplantation. Methods Patients were identified in the UNOS database that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. Patients were grouped according to BMI based on the WHO classification Results Among 3,856 patients the risk of death or delisting was not significantly different between BMI groups (p=0.347). There was no increased risk of death (p=0.234) or delisting (p=0.918). The risk of complication requiring UNOS status upgrade was increased for those with Class II obesity or greater (HR 1.48, 95% CI 1.14–1.93, p=0.004), driven by increased infection and thromboembolism. Obese patients had worse post-transplant outcomes. Weight loss substantial enough to decrease BMI group was achieved by a small proportion of patients listed with Class I obesity or greater (9.6–15.5%). Conclusions Patients with obesity had similar freedom from death or delisting while on LVAD support. However, Class II obese or greater patients had an increased risk of complications requiring UNOS status upgrade compared with those with normal BMI during LVAD support and decreased post-transplant survival. Weight loss on device therapy was possible, but uncommon. Careful consideration is needed when a bridge to weight loss strategy is proposed. PMID:27614942

  12. Genome-Wide Mapping of 5mC and 5hmC Identified Differentially Modified Genomic Regions in Late-Onset Severe Preeclampsia: A Pilot Study.

    Directory of Open Access Journals (Sweden)

    Lisha Zhu

    Full Text Available Preeclampsia (PE is a leading cause of perinatal morbidity and mortality. However, as a common form of PE, the etiology of late-onset PE is elusive. We analyzed 5-methylcytosine (5mC and 5-hydroxymethylcytosine (5hmC levels in the placentas of late-onset severe PE patients (n = 4 and normal controls (n = 4 using a (hydroxymethylated DNA immunoprecipitation approach combined with deep sequencing ([h]MeDIP-seq, and the results were verified by (hMeDIP-qPCR. The most significant differentially methylated regions (DMRs were verified by MassARRAY EppiTYPER in an enlarged sample size (n = 20. Bioinformatics analysis identified 714 peaks of 5mC that were associated with 403 genes and 119 peaks of 5hmC that were associated with 61 genes, thus showing significant differences between the PE patients and the controls (>2-fold, p<0.05. Further, only one gene, PTPRN2, had both 5mC and 5hmC changes in patients. The ErbB signaling pathway was enriched in those 403 genes that had significantly different 5mC level between the groups. This genome-wide mapping of 5mC and 5hmC in late-onset severe PE and normal controls demonstrates that both 5mC and 5hmC play epigenetic roles in the regulation of the disease, but work independently. We reveal the genome-wide mapping of DNA methylation and DNA hydroxymethylation in late-onset PE placentas for the first time, and the identified ErbB signaling pathway and the gene PTPRN2 may be relevant to the epigenetic pathogenesis of late-onset PE.

  13. General and acute care surgical procedures in patients with left ventricular assist devices.

    Science.gov (United States)

    Arnaoutakis, George J; Bittle, Gregory J; Allen, Jeremiah G; Weiss, Eric S; Alejo, Jennifer; Baumgartner, William A; Shah, Ashish S; Wolfgang, Christopher L; Efron, David T; Conte, John V

    2014-04-01

    Left ventricular assist devices (LVADs) have become common as a bridge to heart transplant as well as destination therapy. Acute care surgical (ACS) problems in this population are prevalent but remain ill-defined. Therefore, we reviewed our experience with ACS interventions in LVAD patients. A total of 173 patients who received HeartMate(®) XVE or HeartMate(®) II (HMII) LVADs between December 2001 and March 2010 were studied. Patient demographics, presentation of ACS problem, operative intervention, co-morbidities, transplantation, complications, and survival were analyzed. A total of 47 (27 %) patients underwent 67 ACS procedures at a median of 38 days after device implant (interquartile range 15-110), with a peri-operative mortality rate of 5 % (N = 3). Demographics, device type, and acuity were comparable between the ACS and non-ACS groups. A total of 21 ACS procedures were performed emergently, eight were urgent, and 38 were elective. Of 29 urgent and emergent procedures, 28 were for abdominal pathology. In eight patients, the cause of the ACS problem was related to LVADs or anticoagulation. Cumulative survival estimates revealed no survival differences if patients underwent ACS procedures (p = 0.17). Among HMII patients, transplantation rates were unaffected by an ACS intervention (p = 0.2). ACS problems occur frequently in LVAD patients and are not associated with adverse outcomes in HMII patients. The acute care surgeon is an integral member of a comprehensive approach to effective LVAD management.

  14. The contrast of fast fashion giants Zara, H&M and Uniqlo

    OpenAIRE

    Uriarte Elizaga, Leire

    2016-01-01

    El presente trabajo se centra en la comparación de tres grandes compañías de lo que se conoce como fast fashion o moda rápida. Estas tres compañías son la española Zara, la sueca H&M y la japonesa UNIQLO. Para ello, primero se introduce cada una de las marcas, comentando brevemente su historia para después hablar de la filosofía (misión, visión y valores) y situación financiera de cada una de ellas. A continuación se analiza el modelo de negocio que tiene cada una de las compañ...

  15. Variation of hmF2 and NmF2 deduced from DPS-4 over Multan (Pakistan) and their comparisons with IRI-2012 & IRI-2016 during the deep solar minimum between cycles 23 & 24

    Science.gov (United States)

    Ameen, Muhammad Ayyaz; Khursheed, Haqqa; Jabbar, Mehak Abdul; Ali, Muneeza Salman; Chishtie, Farrukh

    2018-04-01

    We report the results of ionospheric measurements from DPS-4 installed at Multan (Geog coord. 30.18°N, 71.48°E, dip 47.4°). The variations in F2-layer maximum electron density NmF2 and its peak height hmF2 are studied during the deep solar minimum between cycles 23 & 24 i.e 2008-2009 with comparisons conducted with the International Reference Ionosphere (IRI) versions 2012 & 2016. We find that the hmF2 observations peak around the pre-sunrise and sunrise hours depending on the month. Seasonally, the daytime variation of NmF2 is higher in the Equinox and Summer, while daytime hmF2 are slightly higher in the Equinox and Winter. High values of hmF2 around midnight are caused by an increase of upward drifts produced by meridional winds. The ionosphere over Multan, which lies at the verge of low and mid latitude, is affected by both E × B drifts and thermospheric winds as evident from mid-night peaks and near-sunrise dips in hmF2. The results of the comparison of the observed NmF2 and hmF2 for the year 2008-2009 with the IRI-2012 (both NmF2 and hmF2) and IRI-2016 (only hmF2) estimates indicate that for NmF2, IRI-2012 with Consultative Committee International Radio (CCIR) option produces values in better agreement with observed data. Whereas, for hmF2, IRI-2016 with both International Union of Radio Science (URSI) and CCIR SHU-2015 options, predicts well for nighttime hours throughout the year. However, the IRI-2012 with CCIR option produces better agreement with data during daytime hours. Furthermore, IRI-2012 with CCIR option gives better results during Equinox months, whereas, IRI-2016 with both URSI and CCIR SHU-2015 options predict well for Winter and Summer.

  16. Bax/Tubulin/Epithelial-Mesenchymal Pathways Determine the Efficacy of Silybin Analog HM015k in Colorectal Cancer Cell Growth and Metastasis

    Directory of Open Access Journals (Sweden)

    Haneen Amawi

    2018-05-01

    Full Text Available The inhibition of apoptosis, disruption of cellular microtubule dynamics, and over-activation of the epithelial mesenchymal transition (EMT, are involved in the progression, metastasis, and resistance of colorectal cancer (CRC to chemotherapy. Therefore, the design of a molecule that can target these pathways could be an effective strategy to reverse CRC progression and metastasis. In this study, twelve novel silybin derivatives, HM015a-HM015k (15a−15k and compound 17, were screened for cytotoxicity in CRC cell lines. Compounds HM015j and HM015k (15k and 15j significantly decreased cell proliferation, inhibited colony formation, and produced cell cycle arrest in CRC cells. Furthermore, 15k significantly induced the formation of reactive oxygen species and apoptosis. It induced the cleavage of the intrinsic apoptotic protein (Bax p21 to its more efficacious fragment, p18. Compound 15k also inhibited tubulin expression and disrupted its structure. Compound 15k significantly decreased metastatic LOVO cell migration and invasion. Furthermore, 15k reversed mesenchymal morphology in HCT116 and LOVO cells. Additionally, 15k significantly inhibited the expression of the mesenchymal marker N-cadherin and upregulated the expression of the epithelial marker, E-cadherin. Compound 15k inhibited the expression of key proteins known to induce EMT (i.e., DVL3, β-catenin, c-Myc and upregulated the anti-metastatic protein, cyclin B1. Overall, in vitro, 15k significantly inhibited CRC progression and metastasis by inhibiting apoptosis, tubulin activity and the EMT pathways. Overall, these data suggest that compound 15k should be tested in vivo in a CRC animal model for further development.

  17. Combination with a defucosylated anti-HM1.24 monoclonal antibody plus lenalidomide induces marked ADCC against myeloma cells and their progenitors.

    Directory of Open Access Journals (Sweden)

    Takeshi Harada

    Full Text Available The immunomodulatory drug lenalidomide (Len has drawn attention to potentiate antibody-dependent cellular cytotoxicity (ADCC-mediated immunotherapies. We developed the defucosylated version (YB-AHM of humanized monoclonal antibody against HM1.24 (CD317 overexpressed in multiple myeloma (MM cells. In this study, we evaluated ADCC by YB-AHM and Len in combination against MM cells and their progenitors. YB-AHM was able to selectively kill via ADCC MM cells in bone marrow samples from patients with MM with low effector/target ratios, which was further enhanced by treatment with Len. Interestingly, Len also up-regulated HM1.24 expression on MM cells in an effector-dependent manner. HM1.24 was found to be highly expressed in a drug-resistant clonogenic "side population" in MM cells; and this combinatory treatment successfully reduced SP fractions in RPMI 8226 and KMS-11 cells in the presence of effector cells, and suppressed a clonogenic potential of MM cells in colony-forming assays. Collectively, the present study suggests that YB-AHM and Len in combination may become an effective therapeutic strategy in MM, warranting further study to target drug-resistant MM clonogenic cells.

  18. Evaluation of [sup 99m]Tc-HM-PAO thigh accumulation in patients with cerebro-vascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Nishigaki, Hiroshi; Adachi, Itaru; Komori, Tsuyoshi; Tatsu, Yoshimitsu; Hisada, Youichi; Sueyoshi, Kouzou; Narabayashi, Isamu (Osaka Medical College, Takatsuki (Japan))

    1993-06-01

    Technetium-99m d,l-hexamethyl-propyleneamine oxime ([sup 99m]Tc-HM-PAO) cerebral SPECT and whole body scintigraphy (WBS) were performed in 5 patients without cerebro-vascular disease (CVD) (Group 1), 31 patients with CVD but not hemiparesis (Group 2) and 18 patients with CVD and hemiparesis (Group 3). Four ROIs were drawn manually around the whole body (WB), brain (Br), right and left thigh (Th). We calculated some ratios: the total counts in the brain over the total counts in the whole body (Br/WB), the total counts in the thigh over the total counts in the whole body (Th/WB) and the mean counts in the thigh over the mean counts in the brain (Th/Br).The Br/WB was 6.9[+-]1.8%, rt-Th/WB was 4.9[+-]2.1%, lt-Th/WB was 5.1[+-]1.3% and Th/Br was 0.46[+-]0.17 in group 1. Whole body scintigraphies in group 1 revealed clear and similar images between right and left thigh. The Br/WB was 6.7[+-]1.4%, Th/WB of paretic side was 4.6[+-]1.0%, Th/WB of non-paretic side was 5.8[+-]1.2% and Th/Br was 0.47[+-]0.18 in group 3. The Th/WB in non paretic side was significantly higher than that in paretic side (p<0.01). The thigh images in group 3 revealed clear differences between paretic and non-paretic thighes. In conclusion we could acquire the clear thigh images with [sup 99m]Tc-HM-PAO. It was possible that we evaluated not only cerebral perfusion but also muscle atrophy and/or perfusion in patients with CVD using [sup 99m]Tc-HM-PAO. (author).

  19. The Impact of Obesity on Patients Bridged to Transplantation With Continuous-Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Clerkin, Kevin J; Naka, Yoshifumi; Mancini, Donna M; Colombo, Paolo C; Topkara, Veli K

    2016-10-01

    This study sought to determine if obese patients had worse post-left ventricular assist device (LVAD) implantation outcomes and if the implantation of an LVAD allowed for weight loss. Obesity is a risk factor for cardiovascular disease including heart failure. Obese heart failure patients have better outcomes than those with normal weight; however, obese patients have worse outcomes after heart transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) database that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. Patients were grouped according to body mass index (BMI) based on the World Health Organization classification. Among 3,856 patients, the risk of death or delisting was not significantly different between BMI groups (p = 0.347). There was no increased risk of death (p = 0.234) or delisting (p = 0.918). The risk of complication requiring UNOS status upgrade was increased for those with class II obesity or greater (hazard ratio: 1.48; p = 0.004), driven by increased infection and thromboembolism. Obese patients had worse post-transplantation outcomes. Weight loss substantial enough to decrease BMI group was achieved by a small proportion of patients listed with class I obesity or greater (9.6% to 15.5%). Patients with obesity had similar freedom from death or delisting while on LVAD support. However, class II obese or greater patients had an increased risk of complications requiring UNOS status upgrade compared with those with normal BMI during LVAD support and decreased post-transplantation survival. Weight loss on device therapy was possible, but uncommon. Careful consideration is needed when a bridge to weight loss strategy is proposed. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Sandvik's HM 150 roller in action on the world's largest conveyor bridge in the Lusatia region; Sandvik HM 150 auf der weltgroessten Foerderbruecke in der Lausitz im Einsatz

    Energy Technology Data Exchange (ETDEWEB)

    Waliczek, Sven; Raddatz, Ulrich [Sandvik Mining and Construction Central Europe GmbH, Essen (Germany)

    2010-09-15

    Prince Herrmann Ludwig Heinrich von Pueckler-Muskau, a landscape gardening genius, built the Muskau Park in the Lusatia region in 1817 - it is part of a UNESCO world heritage site today. In the same era, 1850, the first lignite was mined in the region and still today, Vattenfall, the Swedish company, extracts lignite without subsidies - in Jaenschwalde among other places, one out of the five opencast mines currently in operation. As one of the largest employers and apprenticing companies in East Germany, Vattenfall currently employs almost 8000 employees and about 800 apprentices. Sandvik Mining and Construction also plays a leading role - in the literal sense. At the Jaenschwalde location there are 320 sets of 5-roller garlands of HM150 formed rollers in action on the overburden conveyor bridge AFB 60m (Figure 1) - on belt five, the main belt conveyor (belt type 3000 ST3000-18:8, idler spacing approx. 800 mm) and on belt eight, the stockpile belt conveyor (belt type 2750 ST2500-18:8, idler spacing approx. 800 mm). It all began in the spring of 2004. Bernhard Hofmayer, Production Manager at Sandvik, introduced the HM150 formed roller to Vattenfall. The engineers were impressed by the completely new design and the innovative assembly technique. The discussion about the advantages and disadvantages of the component optimised formed roller were ready to begin. (orig.)

  1. Complete genome sequence of probiotic Bacillus coagulans HM-08: A potential lactic acid producer.

    Science.gov (United States)

    Yao, Guoqiang; Gao, Pengfei; Zhang, Wenyi

    2016-06-20

    Bacillus coagulans HM-08 is a commercialized probiotic strain in China. Its genome contains a 3.62Mb circular chromosome with an average GC content of 46.3%. In silico analysis revealed the presence of one xyl operon as well as several other genes that are correlated to xylose utilization. The genetic information provided here may help to expand its future biotechnology potential in lactic acid production. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Clinical manifestations and management of left ventricular assist device-associated infections.

    Science.gov (United States)

    Nienaber, Juhsien Jodi C; Kusne, Shimon; Riaz, Talha; Walker, Randall C; Baddour, Larry M; Wright, Alan J; Park, Soon J; Vikram, Holenarasipur R; Keating, Michael R; Arabia, Francisco A; Lahr, Brian D; Sohail, M Rizwan

    2013-11-01

    Infection is a serious complication of left ventricular assist device (LVAD) therapy. Published data regarding LVAD-associated infections (LVADIs) are limited by single-center experiences and use of nonstandardized definitions. We retrospectively reviewed 247 patients who underwent continuous-flow LVAD implantation from January 2005 to December 2011 at Mayo Clinic campuses in Minnesota, Arizona, and Florida. LVADIs were defined using the International Society for Heart and Lung Transplantation criteria. We identified 101 episodes of LVADI in 78 patients (32%) from this cohort. Mean age (± standard deviation [SD]) was 57±15 years. The majority (94%) underwent Heartmate II implantation, with 62% LVADs placed as destination therapy. The most common type of LVADIs were driveline infections (47%), followed by bloodstream infections (24% VAD related, and 22% non-VAD related). The most common causative pathogens included gram-positive cocci (45%), predominantly staphylococci, and nosocomial gram-negative bacilli (27%). Almost half (42%) of the patients were managed by chronic suppressive antimicrobial therapy. While 14% of the patients had intraoperative debridement, only 3 underwent complete LVAD removal. The average duration (±SD) of LVAD support was 1.5±1.0 years. At year 2 of follow-up, the cumulative incidence of all-cause mortality was estimated to be 43%. Clinical manifestations of LVADI vary on the basis of the type of infection and the causative pathogen. Mortality remained high despite combined medical and surgical intervention and chronic suppressive antimicrobial therapy. Based on clinical experiences, a management algorithm for LVADI is proposed to assist in the decision-making process.

  3. 2011 HM102: DISCOVERY OF A HIGH-INCLINATION L5 NEPTUNE TROJAN IN THE SEARCH FOR A POST-PLUTO NEW HORIZONS TARGET

    International Nuclear Information System (INIS)

    Parker, Alex H.; Holman, Matthew J.; McLeod, Brian A.; Buie, Marc W.; Borncamp, David M.; Spencer, John R.; Stern, S. Alan; Osip, David J.; Gwyn, Stephen D. J.; Fabbro, Sébastian; Kavelaars, J. J.; Benecchi, Susan D.; Sheppard, Scott S.; Binzel, Richard P.; DeMeo, Francesca E.; Fuentes, Cesar I.; Trilling, David E.; Gay, Pamela L.; Petit, Jean-Marc; Tholen, David J.

    2013-01-01

    We present the discovery of a long-term stable L5 (trailing) Neptune Trojan in data acquired to search for candidate trans-Neptunian objects for the New Horizons spacecraft to fly by during an extended post-Pluto mission. This Neptune Trojan, 2011 HM 102 , has the highest inclination (29.°4) of any known member of this population. It is intrinsically brighter than any single L5 Jupiter Trojan at H V ∼ 8.18. We have determined its gri colors (a first for any L5 Neptune Trojan), which we find to be similar to the moderately red colors of the L4 Neptune Trojans, suggesting similar surface properties for members of both Trojan clouds. We also present colors derived from archival data for two L4 Neptune Trojans (2006 RJ 103 and 2007 VL 305 ), better refining the overall color distribution of the population. In this document we describe the discovery circumstances, our physical characterization of 2011 HM 102 , and this object's implications for the Neptune Trojan population overall. Finally, we discuss the prospects for detecting 2011 HM 102 from the New Horizons spacecraft during its close approach in mid- to late-2013.

  4. Neurohormonal activation and exercise tolerance in patients supported with a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Jung, Mette Holme; Goetze, Jens Peter; Boesgaard, Soeren

    2016-01-01

    BACKGROUND: Neurohormones play a key role in regulating hemodynamics in heart failure (HF) both at rest and during exercise. In contrast, little is known about the importance of neurohormonal regulation for exercise capacity in continuous-flow left ventricular assist device (CF-LVAD) patients....... The aim of this study was to assess the relation between neurohormonal activation patterns in CF-LVAD patients and exercise capacity. METHODS: Plasma concentrations of the C-terminal portion of pro-arginine vasopressin precursor (copeptin), pro-adrenomedullin (proADM), pro-B-type (proBNP) and pro......-atrial (proANP) natriuretic peptides were measured in 25 CF-LVAD patients (HeartMate II) in the morning prior to maximal cardiopulmonary exercise testing determining peak oxygen uptake (peak VO2). Quality of life (QOL) was determined by questionnaires. RESULTS: Peak VO2 was severely reduced averaging 13...

  5. Geen recht de moed te verliezen. Leven en werken van dr. H.M. de Lange (1919-2001)

    NARCIS (Netherlands)

    Witte-Rang, M.E.

    2008-01-01

    This study deals with the contribution of the Dutch economist Dr. H.M. de Lange to the ecumenical debate on social-ethics. To this end, the first part gives a description of the work of De Lange. Through the individual De Lange the study provides an insight in the worldwide ecumenical movement and

  6. Cerebrovascular Accidents During Mechanical Circulatory Support: New Predictors of Ischemic and Hemorrhagic Strokes and Outcome.

    Science.gov (United States)

    Izzy, Saef; Rubin, Daniel B; Ahmed, Firas S; Akbik, Feras; Renault, Simone; Sylvester, Katelyn W; Vaitkevicius, Henrikas; Smallwood, Jennifer A; Givertz, Michael M; Feske, Steven K

    2018-05-01

    Left ventricular assist devices (LVADs) have emerged as an effective treatment for patients with advanced heart failure refractory to medical therapy. Post-LVAD strokes are an important cause of morbidity and reduced quality of life. Data on risks that distinguish between ischemic and hemorrhagic post-LVAD strokes are limited. The aim of this study was to determine the incidence of post-LVAD ischemic and hemorrhagic strokes, their association with stroke risk factors, and their effect on mortality. Data are collected prospectively on all patients with LVADs implanted at Brigham and Women's Hospital. We added retrospectively collected clinical data for these analyses. From 2007 to 2016, 183 patients (median age, 57; 80% male) underwent implantation of HeartMate II LVAD as a bridge to transplant (52%), destination therapy (39%), or bridge to transplant candidacy (8%). A total of 48 strokes occurred in 39 patients (21%): 28 acute ischemic strokes in 24 patients (13%) and 20 intracerebral hemorrhages in 19 patients (10.3%). First events occurred at a median of 238 days from implantation (interquartile range, 93-515) among those who developed post-LVAD stroke. All but 9 patients (4.9%) were on warfarin (goal international normalized ratio, 2-3.5) and all received aspirin (81-325 mg). Patients with chronic obstructive pulmonary disease were more likely to have an ischemic stroke (odds ratio, 2.96; 95% confidence interval, 1.14-7.70). Dialysis-dependent patients showed a trend toward a higher risk of hemorrhagic stroke (odds ratio, 6.31; 95% confidence interval, 0.99-40.47). Hemorrhagic stroke was associated with higher mortality (odds ratio, 3.92; 95% confidence interval, 1.34-11.45) than ischemic stroke (odds ratio, 3.17; 95% confidence interval, 1.13-8.85). Stroke is a major cause of morbidity and mortality in patients on LVAD support. Chronic obstructive pulmonary disease increases the risk of ischemic stroke, whereas dialysis may increase the risk of hemorrhagic

  7. Simulación con Monte Carlo para dosimetría de 153Samario-HM en un modelo anatómico geométrico de rodilla humana

    Directory of Open Access Journals (Sweden)

    Hardy Pérez Alberto Ernesto

    2010-01-01

    Full Text Available El 153Sm-hm es una nueva opción para realizar sinovectomía por radiación, que actualmente se encuentra en valoración. Este trabajo tiene como objetivo calcular la dosis absorbida en tejidos articulares proporcionada por la administración de 153Sm-hm intraarticular, utilizando la simulación de Monte Carlo, en una propuesta de un modelo simplificado anatómico geométrico de la articulación de la rodilla. Esto con el propósito de aportar datos que apoyen la administración segura y eficaz del radiofármaco en estudio a pacientes con enfermedad reumática de la articulación de la rodilla. Se concluye que la actividad administrada de 153Sm-hm por vía intra-articular es de 370 MBq para conseguir una dosis absorbida en membrana sinovial de 110 Gy, considerada como la dosis de ablación de la mencionada membrana.

  8. 75 FR 34117 - Proposed CERCLA Section 122(h) Cost Recovery Settlement for the H.M. Quackenbush, Inc. Superfund...

    Science.gov (United States)

    2010-06-16

    ... and majority shareholder of H.M. Quackenbush, Inc., to pay EPA, in nine annual installments, $225,000.00, plus interest, for EPA's past response costs incurred at the Site. The Settling Party also agrees to pay $75,000.00 pursuant to a settlement with the Village of Herkimer into an interest-bearing...

  9. Hemodynamic deterioration precedes onset of ventricular tachyarrhythmia after Heartmate II implantation.

    Science.gov (United States)

    Yaksh, Ameeta; Kik, Charles; Knops, Paul; Zwiers, Korinne; van Ettinger, Maarten J B; Manintveld, Olivier C; de Wijs, Marcel C J; van der Kemp, Peter; Bogers, Ad J J C; de Groot, Natasja M S

    2016-07-08

    Early postoperative ventricular tachyarrhythmia (PoVT) after left ventricular assist device (LVAD) implantation are common and associated with higher mortality-rates. At present, there is no data on initiation of these PoVT and the role of alterations in cardiac hemodynamics. A LVAD was implanted in a patient with end-stage heart failure due to a ischemic cardiomyopathy. Alterations in cardiac rhythm and hemodynamics preceding PoVT-episodes during the first five postoperative days were examined by using continuous recordings of cardiac rhythm and various hemodynamic parameters. All PoVT (N=120) were monomorphic, most often preceded by short-long-short-sequences or regular SR and initiated by ventricular runs. Prior to PoVT, mean arterial pressure decreased; heart rate and ST-segments deviations increased. PoVT are caused by different underlying electrophysiological mechanisms. Yet, they are all monomorphic and preceded by hemodynamic deterioration due to myocardial ischemia.

  10. Left ventricular assist device exchange: the Toronto General Hospital experience.

    Science.gov (United States)

    Tsubota, Hideki; Ribeiro, Roberto V P; Billia, Filio; Cusimano, Robert J; Yau, Terrence M; Badiwala, Mitesh V; Stansfield, William E; Rao, Vivek

    2017-08-01

    As support times for left ventricular assist devices (LVADs) become longer, several complications requiring device exchange may occur. To our knowledge, this is the first Canadian report regarding implantable LVAD exchange. We retrospectively reviewed the cases of consecutive, unique patients implanted with an LVAD between June 2006 and October 2015 at Toronto General Hospital. In total, 122 patients were impanted with an LVAD during the study period. Eight patients required LVAD exchange, and 1 patient had 2 replacements (9 of 122, 7.3%). There were 7 HeartMate II (HMII), 1 HVAD and 1 DuraHeart pumps exchanged. Two of these exchanges occurred early at the time of initial implant, whereas 7 occurred late (range 8-623 d). Six exchanges were made owing to pump thrombosis. Of the 3 exchanges made for other causes, 1 HMII exchange was owing to a driveline fracture, 1 DuraHeart patient had early inflow obstruction requiring exchange to HMII at the initial implant, and the third had a suspected inflow obstruction with no evidence of thrombosis at the time of the procedure. The mean support time before exchange was 225 days, and time from exchange to transplant, death or ongoing support was 245 days. Three patients were successfully bridged to transplant, and at the time of data collection 2 were supported awaiting transplant. Three patients died after a mean duration of 394.3 days (range 78-673 d) of support postreplacement. Four cases were successfully performed using a subcostal approach. Pump thrombosis is the most common cause for LVAD exchange, which can be performed with acceptable morbidity and mortality. The subcostal approach may be the preferred procedure for an HMII exchange when indicated.

  11. Case Report of Multiembolic Cerebrovascular Event Associated with Ramp Study Echocardiogram

    Directory of Open Access Journals (Sweden)

    Brian C. Butera

    2017-01-01

    Full Text Available The incidence of ramp test echocardiogram-associated embolic events in the setting of therapeutic anticoagulation is likely rare and has not been reported. We present such a case in a patient with a HeartMate II left ventricular assist device (LVAD whose serial head computed tomography images, deteriorating clinical course, and the multiembolic nature of the event suggest causality. If the pretest probability of pump thrombosis in an individual LVAD patient is sufficiently high, the potential risks of performing a ramp study echocardiogram may not be warranted, even in the setting of adequate anticoagulation.

  12. Description and advantages of the new and dry total mercury CEM HM 14000 trust

    Energy Technology Data Exchange (ETDEWEB)

    Kasajanow, J.

    2002-07-01

    A series of 24 overheads/slides outline the presentation giving details of the design and operation of the continuous emission monitor - the Total Mercury CEM HM 1400TR produced by the Durag Group. The monitor is suitable for measuring mercury emitted from power plants. The principle components of the monitor, the thermocatalytic reactor, and the dual beam UV detector are described, along with the calibration. Also the Portable Total Mercury CEM and the Total Mercury CEM 1500 for liquids are pictured. The presentation was made by Verewa, part of the Durag Group.

  13. A study of 99mTc-HM-PAO brain SPECT in the senile parkinson's disease

    International Nuclear Information System (INIS)

    Chen Wenxin; Lin Xiangtong; Song Wenzhong; Liu Yongchang

    1996-01-01

    Thirty-three cases of senile Parkinson's disease (PD) imaged by 99m Tc-HM-PAO brain SPECT were reported. 66.7% of the patients had cortical hypoperfusion and 18.2% showed asymmetrical hypoperfusion in the basal ganglia. Such a finding was not related with the Hoehn-Yahr stage and the laterality of motor symptoms. If complicated with dementia, the SPECT brain imaging showed similar pattern in Alzheimer's disease with diffuse hypoperfusion in cortical area reflecting widespread pathological changes in tremor paralysis

  14. 2011 HM{sub 102}: DISCOVERY OF A HIGH-INCLINATION L5 NEPTUNE TROJAN IN THE SEARCH FOR A POST-PLUTO NEW HORIZONS TARGET

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Alex H.; Holman, Matthew J.; McLeod, Brian A. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Buie, Marc W.; Borncamp, David M.; Spencer, John R.; Stern, S. Alan [Southwest Research Institute, 6220 Culebra Road, San Antonio, TX 78238 (United States); Osip, David J. [Carnegie Observatories, Las Campanas Observatory, Casilla 601, La Serena (Chile); Gwyn, Stephen D. J.; Fabbro, Sebastian; Kavelaars, J. J. [Canadian Astronomy Data Centre, National Research Council of Canada, 5071 W. Saanich Road, Victoria, BC V9E 2E7 (Canada); Benecchi, Susan D.; Sheppard, Scott S. [Department of Terrestrial Magnetism, Carnegie Institute of Washington, 5251 Broad Branch Road NW, Washington, DC 20015 (United States); Binzel, Richard P.; DeMeo, Francesca E. [Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Fuentes, Cesar I.; Trilling, David E. [Department of Physics and Astronomy, Northern Arizona University, S San Francisco St, Flagstaff, AZ 86011 (United States); Gay, Pamela L. [Center for Science, Technology, Engineering and Mathematics (STEM) Research, Education, and Outreach, Southern Illinois University, 1220 Lincoln Dr, Carbondale, IL 62901 (United States); Petit, Jean-Marc [CNRS, UTINAM, Universite de Franche Comte, Route de Gray, F-25030 Besancon Cedex, (France); Tholen, David J., E-mail: aparker@cfa.harvard.edu [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Dr, Honolulu, HI 96822 (United States); and others

    2013-04-15

    We present the discovery of a long-term stable L5 (trailing) Neptune Trojan in data acquired to search for candidate trans-Neptunian objects for the New Horizons spacecraft to fly by during an extended post-Pluto mission. This Neptune Trojan, 2011 HM{sub 102}, has the highest inclination (29. Degree-Sign 4) of any known member of this population. It is intrinsically brighter than any single L5 Jupiter Trojan at H{sub V} {approx} 8.18. We have determined its gri colors (a first for any L5 Neptune Trojan), which we find to be similar to the moderately red colors of the L4 Neptune Trojans, suggesting similar surface properties for members of both Trojan clouds. We also present colors derived from archival data for two L4 Neptune Trojans (2006 RJ{sub 103} and 2007 VL{sub 305}), better refining the overall color distribution of the population. In this document we describe the discovery circumstances, our physical characterization of 2011 HM{sub 102}, and this object's implications for the Neptune Trojan population overall. Finally, we discuss the prospects for detecting 2011 HM{sub 102} from the New Horizons spacecraft during its close approach in mid- to late-2013.

  15. Performance-oriented packaging: A guide to identifying and designing. Identifying and designing hazardous materials packaging for compliance with post HM-181 DOT Regulations

    International Nuclear Information System (INIS)

    1994-08-01

    With the initial publication of Docket HM-181 (hereafter referred to as HM-181), the U.S. Department of Energy (DOE), Headquarters, Transportation Management Division decided to produce guidance to help the DOE community transition to performance-oriented packagings (POP). As only a few individuals were familiar with the new requirements, elementary guidance was desirable. The decision was to prepare the guidance at a level easily understood by a novice to regulatory requirements. This document identifies design development strategies for use in obtaining performance-oriented packagings that are not readily available commercially. These design development strategies will be part of the methodologies for compliance with post HM-181 U.S. Department of Transportation (DOT) packaging regulations. This information was prepared for use by the DOE and its contractors. The document provides guidance for making decisions associated with designing performance-oriented packaging, and not for identifying specific material or fabrication design details. It does provide some specific design considerations. Having a copy of the regulations handy when reading this document is recommended to permit a fuller understanding of the requirements impacting the design effort. While this document is not written for the packaging specialist, it does contain guidance important to those not familiar with the new POP requirements

  16. pH-regulated metal-ligand switching in the HM loop of ATP7A: a new paradigm for metal transfer chemistry.

    Science.gov (United States)

    Kline, Chelsey D; Gambill, Benjamin F; Mayfield, Mary; Lutsenko, Svetlana; Blackburn, Ninian J

    2016-08-01

    Cuproproteins such as PHM and DBM mature in late endosomal vesicles of the mammalian secretory pathway where changes in vesicle pH are employed for sorting and post-translational processing. Colocation with the P1B-type ATPase ATP7A suggests that the latter is the source of copper and supports a mechanism where selectivity in metal transfer is achieved by spatial colocation of partner proteins in their specific organelles or vesicles. In previous work we have suggested that a lumenal loop sequence located between trans-membrane helices TM1 and TM2 of the ATPase, and containing five histidines and four methionines, acts as an organelle-specific chaperone for metallation of the cuproproteins. The hypothesis posits that the pH of the vesicle regulates copper ligation and loop conformation via a mechanism which involves His to Met ligand switching induced by histidine protonation. Here we report the effect of pH on the HM loop copper coordination using X-ray absorption spectroscopy (XAS), and show via selenium substitution of the Met residues that the HM loop undergoes similar conformational switching to that found earlier for its partner PHM. We hypothesize that in the absence of specific chaperones, HM motifs provide a template for building a flexible, pH-sensitive transfer site whose structure and function can be regulated to accommodate the different active site structural elements and pH environments of its partner proteins.

  17. Modification of the Assessment of Life Habits (LIFE-Hm) to consider personalized satisfaction with participation in activities and roles: results from a construct validity study with older adults.

    Science.gov (United States)

    Roy-Bouthot, Kathleen; Filiatrault, Patrick; Caron, Cyndi; Gagnon, Maxime; Prémont, Stéphanie; Levasseur, Mélanie

    2014-01-01

    Participation, defined as a person's involvement in activities and roles, is a primary intervention goal in rehabilitation. To achieve client-centered practice, rehabilitation professionals need to go beyond objective accomplishment criteria and consider satisfaction with and the importance of participation in activities and roles. To our knowledge, no instrument considers accomplishment, satisfaction and importance of activities and roles, and allows numerical scoring and comparison. The objectives of this study were to modify the Assessment of Life Habits questionnaire (LIFE-Hm) to consider personalized satisfaction (satisfaction weighted by importance) with participation in activities and roles, and to: (1) examine its convergent validity with quality of life (QOL) and (2) compare the associations between QOL on the one hand and, satisfaction (LIFE-H) and personalized satisfaction (LIFE-Hm) with participation on the other. A descriptive cross-sectional study was conducted with 84 older adults, average age 76 years, with different functional autonomy levels. Quality of life was associated with personalized satisfaction for all categories of activities and roles (r = 0.45 to 0.75; p study found good construct validity of the LIFE-Hm with QOL. Personalization can add value in achieving client-centered practice. Implications for Rehabilitation The LIFE-Hm becomes the first instrument available in English and French that allows comparison between individuals and informs rehabilitation professionals about the level of accomplishment, satisfaction and personalized satisfaction with participation in activities and roles. Personalized satisfaction can add value in achieving client-centered practice as it considers not only how satisfying activities and roles are for the person, but also the importance that these activities and roles have for her/him. The LIFE-Hm offers the advantage of systematically identifying activities and roles which are not satisfactory but

  18. Continuous flow left ventricular assist devices: shared care goals of monitoring and treating patients.

    Science.gov (United States)

    Estep, Jerry D; Trachtenberg, Barry H; Loza, Laurie P; Bruckner, Brian A

    2015-01-01

    Continuous-flow left ventricular assist devices (CF-LVADs) have been clinically adopted as a long-term standard of care therapy option for patients with end-stage heart failure. For many patients, shared care between the care providers at the implanting center and care providers in the community in which the patient resides is a clinical necessity. The aims of this review are to (1) provide a rationale for the outpatient follow-up exam and surveillance testing used at our center to monitor patients supported by the HeartMate II(®) CF-LVAD (Thoratec Corporation, Pleasanton, CA) and (2) provide the protocol/algorithms we use for blood pressure, driveline exit site, LVAD alarm history, surveillance blood work, and echocardiography monitoring in this patient population. In addition, we define our partnership outpatient follow-up protocol and the "shared care" specific responsibilities we use with referring health care providers to best manage many of our patients.

  19. Precision temperature monitoring (PTM) and Humidity monitoring (HM) sensors of the CMS electromagnetic calorimeter

    CERN Multimedia

    2006-01-01

    A major aspect for the ECAL detector control is the monitoring of the system temperature and the verification that the required temperature stability of the crystal volume and the APDs, expected to be (18 ± 0.05)C, is achieved. The PTM is designed to read out thermistors, placed on both the front and back of the crystals, with a relative precision better than 0.01 C. In total there are ten sensors per supermodule. The humidity level in the electronics compartment is monitored by the HM system and consists of one humidity sensor per module.

  20. Coupled HM modelling of the mine-by test at Meuse-Haute-Marne (MHM) URL France

    International Nuclear Information System (INIS)

    Yildizdag, K.; Shao, H.; Hesser, J.; Soennke, J.; Noiret, A.

    2012-01-01

    Document available in extended abstract form only. In order to test the feasibility of disposing High-Level and Long-Lived Wastes (HLW-LL) in Callovo- Oxfordian clay formation (COx), the French National Radioactive Waste Management Agency (ANDRA) has carried out scientific and engineering investigations in the Meuse-Haute-Marne Underground Research Laboratory (URL) since November 1999. The COx (Figure 1) is of a special interest because of its very favourable characteristics for being a possible host rock for the disposal of radioactive waste. The project OHZ (Observation and Monitoring of the EDZ) was initiated in 2008 by ANDRA. In the framework of this project, a Mine-by experiment was performed in the niche GCS. The excavation was started on 29.01.2008. Displacement and pore pressure evolution during the excavation was measured by different sensors. Within the cooperation between BGR and ANDRA numerical calculations have been done using the code RockFlow to understand the hydraulic and mechanical (HM) coupling mechanisms of Callovo-Oxfordian clay-stone observed during the Mine-by experiment. Modelling results: With regard to the bedding of COx a transverse isotropy approach was applied. Thus the anisotropy effects caused by the bedding have been considered in coupled HM models (Massmann, 2009). Intensive parameter studies in comparison with measured deformation and pore pressure data have been conducted to reduce modelling uncertainties. Fully saturated models yield very precise results in the far field wherein excavation effect has its lower impact. Rapid decline of pore pressure and continuously increasing deformation subsequent to excavation in the near field could not be interpreted even taking shrinkage and partially saturation into consideration. During the Mine-by test, overpressures on sidewalls and reduced pressures on roof and floor were measured due to the mechanical effect on pore pressure which is induced by the bedding. Good agreement between

  1. Association between cell-derived microparticles and adverse events in patients with nonpulsatile left ventricular assist devices.

    Science.gov (United States)

    Nascimbene, Angelo; Hernandez, Ruben; George, Joggy K; Parker, Anita; Bergeron, Angela L; Pradhan, Subhashree; Vijayan, K Vinod; Civitello, Andrew; Simpson, Leo; Nawrot, Maria; Lee, Vei-Vei; Mallidi, Hari R; Delgado, Reynolds M; Dong, Jing Fei; Frazier, O H

    2014-05-01

    Continuous-flow left ventricular assist devices (LVADs) expose blood cells to high shear stress, potentially resulting in the production of microparticles that express phosphatidylserine (PS+) and promote coagulation and inflammation. In this prospective study, we attempted to determine whether PS+ microparticle levels correlate with clinical outcomes in LVAD-supported patients. We enrolled 20 patients undergoing implantation of the HeartMate II LVAD (Thoratec Corp, Pleasanton, CA) and 10 healthy controls who provided reference values for the microparticle assays. Plasma was collected before LVAD implantation, at discharge, at the 3-month follow-up, and when an adverse clinical event occurred. We quantified PS+ microparticles in the plasma using flow cytometry. During the study period, 8 patients developed adverse clinical events: ventricular tachycardia storm in 1, non-ST-elevation myocardial infarction in 2, arterial thrombosis in 2, gastrointestinal bleeding in 2, and stroke in 3. Levels of PS+ microparticles were higher in patients at baseline than in healthy controls (2.11% ± 1.26% vs 0.69% ± 0.46%, p = 0.007). After LVAD implantation, patient PS+ microparticle levels increased to 2.39% ± 1.22% at discharge and then leveled to 1.97% ± 1.25% at the 3-month follow-up. Importantly, levels of PS+ microparticles were significantly higher in patients who developed an adverse event than in patients with no events (3.82% ± 1.17% vs 1.57% ± 0.59%, p microparticle levels may be associated with adverse clinical events. Thus, measuring PS+ microparticle levels in LVAD-supported patients may help identify patients at increased risk for adverse events. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  2. The vexing problem of thrombosis in long-term mechanical circulatory support.

    Science.gov (United States)

    Mehra, Mandeep R; Stewart, Garrick C; Uber, Patricia A

    2014-01-01

    Durable left ventricular assist devices (LVADs) have not only enhanced longevity but also conferred sustained improvements in quality of life, symptom control, and functional capacity in patients with medically refractory advanced heart failure. Problems with device-related infection, bleeding, neurologic events, right-sided heart failure, and device malfunction have dominated the clinical care of patients living on mechanical support. Even as adoption of durable LVADs accelerated globally, we began to encounter a growing dilemma of pump malfunction caused by thrombosis. In early 2011, clinicians began to notice a spike in the incidence of pump thrombosis with the HeartMate II (Thoratec Corp, Pleasanton, CA) LVAD. By 2012, the problem of thrombosis in LVADs began to consume most of the scientific direction as centers and collaborative groups began to dissect this nascent phenomenon. In this perspective, we describe the magnitude and implications of pump thrombosis, discuss secular and management trends in this unique population, attempt to dissect the problem at its root, offer guidance on surveillance and therapeutic principles, and outline issues that deserve our immediate and collaborative attention. © 2014 International Society for Heart and Lung Transplantation Published by International Society for the Heart and Lung Transplantation All rights reserved.

  3. Highly efficient PCR assay to discriminate allelic DNA methylation status using whole genome amplification

    Directory of Open Access Journals (Sweden)

    Ito Takashi

    2011-06-01

    Full Text Available Abstract Background We previously developed a simple method termed HpaII-McrBC PCR (HM-PCR to discriminate allelic methylation status of the genomic sites of interest, and successfully applied it to a comprehensive analysis of CpG islands (CGIs on human chromosome 21q. However, HM-PCR requires 200 ng of genomic DNA to examine one target site, thereby precluding its application to such samples that are limited in quantity. Findings We developed HpaII-McrBC whole-genome-amplification PCR (HM-WGA-PCR that uses whole-genome-amplified DNA as the template. HM-WGA-PCR uses only 1/100th the genomic template material required for HM-PCR. Indeed, we successfully analyzed 147 CGIs by HM-WGA-PCR using only ~300 ng of DNA, whereas previous HM-PCR study had required ~30 μg. Furthermore, we confirmed that allelic methylation status revealed by HM-WGA-PCR is identical to that by HM-PCR in every case of the 147 CGIs tested, proving high consistency between the two methods. Conclusions HM-WGA-PCR would serve as a reliable alternative to HM-PCR in the analysis of allelic methylation status when the quantity of DNA available is limited.

  4. Positive allosteric modulation of the human metabotropic glutamate receptor 4 (hmGluR4) by SIB-1893 and MPEP

    DEFF Research Database (Denmark)

    Mathiesen, Jesper Mosolff; Svendsen, Nannette; Bräuner-Osborne, Hans

    2003-01-01

    We have identified 2-methyl-6-(2-phenylethenyl)pyridine (SIB-1893) and 2-methyl-6-phenylethynyl pyridine hydrochloride (MPEP) as positive allosteric modulators for the hmGluR4. SIB-1893 and MPEP enhanced the potency and efficacy of L-2-amino-4-phophonobutyrate (L-AP4) in guanosine 5'-O-(3-[(35)S...

  5. E072/ST-HM - A dynamic maintenance strategie to meet the requirements of the LHC installation

    OpenAIRE

    Böttcher, O

    2003-01-01

    The new ST-HM contract E072 for the maintenance of transport and handling equipment is designed to obtain the high operating reliability as required for the LHC installation and to respect the situation of limited resources at CERN at the same time. The contract is based on a dynamic maintenance strategy. It contains a flexible maintenance contingent that is essential to prepare the equipment for extremely important and critical utilization phases that will come up during the LHC installation...

  6. ähm vs. niinku - Verzögerungssignale in deutschen und finnischen Diskussionen

    Directory of Open Access Journals (Sweden)

    Margarethe Olbertz-Siitonen

    2015-05-01

    Full Text Available Dieser Beitrag beschäftigt sich kontrastiv mit dem Gebrauch von Verzögerungssignalen in deutschen und finnischen Seminardiskussionen. Die voranalytische  Durchsicht der Videomitschnitte zeigte, dass die deutschen Studenten unvergleichlich  häufiger die Verzögerungspartikeln äh und ähm  einsetzten als ihre finnischen Kommilitonen, die in ähnlicher Funktion v.a. die Partikel niinku ('sozusagen' benutzten. Diese  Beobachtung ist insofern von Bedeutung, als es meist die finnischen Gesprächsteilnehmer sind, die in deutsch-finnischen Kontaktsituationen auf eine Fremdsprache (Deutsch  zurückgreifen müssen: Möglicherweise steht finnischen Gesprächspartnern in der Interaktion mit deutschen Muttersprachlern keine deutsche Entsprechung für niinku zur Ver- fügung. Gegebenenfalls resultierende Kommunikationsprobleme sollten dementsprechend nicht vornehmlich interkulturell, sondern interlingual bewertet werden.

  7. The Relationship between Ionospheric Slab Thickness and the Peak Density Height, hmF2

    Science.gov (United States)

    Meehan, J.; Sojka, J. J.

    2017-12-01

    The electron density profile is one of the most critical elements in the ionospheric modeling-related applications today. Ionosphere parameters, hmF2, the height of the peak density layer, and slab thickness, the ratio of the total electron content, TEC, to the peak density value, NmF2, are generally obtained from any global sounding observation network and are easily incorporated into models, theoretical or empirical, as numerical representations. Slab thickness is a convenient one-parameter summary of the electron density profile and can relate a variety of elements of interest that effect the overall electron profile shape, such as the neutral and ionospheric temperatures and gradients, the ionospheric composition, and dynamics. Using ISR data from the 2002 Millstone Hill ISR data campaign, we found, for the first time, slab thickness to be correlated to hmF2. For this, we introduce a new ionospheric index, k, which ultimately relates electron density parameters and can be a very useful tool for describing the topside ionosphere shape. Our study is an initial one location, one season, 30-day study, and future work is needed to verify the robustness of our claim. Generally, the ionospheric profile shape, requires knowledge of several ionospheric parameters: electron, ion and neutral temperatures, ion composition, electric fields, and neutral winds, and is dependent upon seasons, local time, location, and the level of solar and geomagnetic activity; however, with this new index, only readily-available, ionospheric density information is needed. Such information, as used in this study, is obtained from a bottomside electron density profile provided by an ionosonde, and TEC data provided by a local, collocated GPS receiver.

  8. Single photon emission tomography using sup(99m)Tc-HM-PAO in the investigation of dementia

    Energy Technology Data Exchange (ETDEWEB)

    Neary, D; Snowden, J S; Shields, R A; Burjan, A W.I.; Northen, B; Macdermott, N; Prescott, M C; Testa, H J

    1987-09-01

    Single photon emission tomographic imaging of the brain using sup(99m)Tc HM-PAO was carried out in patients with a clinical diagnosis of Alzheimer's disease, non-Alzheimer frontal-lobe dementia, and progressive supranuclear palsy. Independent assessment of reductions in uptake revealed posterior hemisphere abnormalities in the majority of the Alzheimer group, and selective anterior hemisphere abnormalities in both other groups. The findings were consistent with observed patterns of mental impairment. The imaging technique has potential value in the differential diagnosis of primary cerebral atrophy.

  9. Studies for labelling of leukocytes with sup 99m Tc-HM-PAO in vitro and animal experiments

    Energy Technology Data Exchange (ETDEWEB)

    Zhaoxiang, Gu; Xiangtong, Lin [Shanghai Medical Univ. (China). Huashan Hospital

    1989-05-01

    A technigue for in vitro labelling of human leukocytes with {sup 99m}Tc-HM-PAO is described. The percentage of labelled leukocytes is 43.0 +- 5.0 (mean +- SD, n = 6). Cell function was not impaired by the labelling procedure. Sterility and exclusion of bacterial endotoxins in the final cell suspensions were demonstrated. In experiments on dogs with abscess, scintigraphic imaging showed accumulation of radioactivity in inflammation lesions, indicating the viability of the labelled leukocytes.

  10. Ton H.M. van Schaik and Karin Strengers-Olde Kalter, Het Arme Roomse Leven. Geschiedenis van de katholieke caritas in de stad Utrecht

    Directory of Open Access Journals (Sweden)

    Joost van Genabeek

    2017-07-01

    Full Text Available Ton H.M. van Schaik and Karin Strengers-Olde Kalter, Het Arme Roomse Leven. Geschiedenis van de katholieke caritas in de stad Utrecht (Hilversum: Verloren, 2016, 276 pp., isbn 978 90 8704 578 4.

  11. Opportunistic Infections (OIs) in Patients with Hematologic Malignancies (HM) Treated with Bruton’s Tyrosine Kinase (BTK) and Phosphoinositide 3 Kinase (PI3K) Inhibitors: An 8-Year Retrospective Cohort Study

    OpenAIRE

    Issa, Nicolas; Arbona-Haddad, Esther; Nevett-Fernandez, Alexandra; Prestes, Daniel; Liakos, Alexis; Woolley, Ann; Hammond, Sarah; Brown, Jennifer; Baden, Lindsey; Marty, Francisco

    2017-01-01

    Abstract Background: BTK and PI3K inhibitors are increasingly used for treatment in patients with HM. OIs when these agents were used as first line therapy signaled an increased level of immunosuppression beyond what was expected from the mechanism of action of these drugs. The epidemiology of OIs in the setting of BTK and PI3K inhibitor use has not been characterized. Methods: We retrospectively studied a cohort of patients with HM who received BTK (ibrutinib, acalabrutinib, spebrutinib) or ...

  12. The Aorta-Gonad-Mesonephros Organ Culture Recapitulates 5hmC Reorganization and Replication-Dependent and Independent Loss of DNA Methylation in the Germline.

    Science.gov (United States)

    Calvopina, Joseph Hargan; Cook, Helene; Vincent, John J; Nee, Kevin; Clark, Amander T

    2015-07-01

    Removal of cytosine methylation from the genome is critical for reprogramming and transdifferentiation and plays a central role in our understanding of the fundamental principles of embryo lineage development. One of the major models for studying cytosine demethylation is the mammalian germ line during the primordial germ cell (PGC) stage of embryo development. It is now understood that oxidation of 5-methylcytosine (5mC) to 5-hydroxymethylcytosine (5hmC) is required to remove cytosine methylation in a locus-specific manner in PGCs; however, the mechanisms downstream of 5hmC are controversial and hypothesized to involve either active demethylation or replication-coupled loss. In the current study, we used the aorta-gonad-mesonephros (AGM) organ culture model to show that this model recapitulates germ line reprogramming, including 5hmC reorganization and loss of cytosine methylation from Snrpn and H19 imprinting control centers (ICCs). To directly address the hypothesis that cell proliferation is required for cytosine demethylation, we blocked PI3-kinase-dependent PGC proliferation and show that this leads to a G1 and G2/M cell cycle arrest in PGCs, together with retained levels of cytosine methylation at the Snrpn ICC, but not at the H19 ICC. Taken together, the AGM organ culture model is an important tool to evaluate mechanisms of locus-specific demethylation and the role of PI3-kinase-dependent PGC proliferation in the locus-specific removal of cytosine methylation from the genome.

  13. CBF tomograms with [/sup 99m/Tc-HM-PAO in patients with dementia (Alzheimer type and HIV) and Parkinson's disease--initial results

    International Nuclear Information System (INIS)

    Costa, D.C.; Ell, P.J.; Burns, A.; Philpot, M.; Levy, R.

    1988-01-01

    We present preliminary data on the utility of functional brain imaging with [99mTc]-d,l-HM-PAO and single photon emission computed tomography (SPECT) in the study of patients with dementia of the Alzheimer type (DAT), HIV-related dementia syndrome, and the on-off syndrome of Parkinson's disease. In comparison with a group of age-matched controls, the DAT patients revealed distinctive bilateral temporal and posterior parietal deficits, which correlate with detailed psychometric evaluation. Patients with amnesia as the main symptom (group A) showed bilateral mesial temporal lobe perfusion deficits (p less than 0.02). More severely affected patients (group B) with significant apraxia, aphasia, or agnosia exhibited patterns compatible with bilateral reduced perfusion in the posterior parietal cortex, as well as reduced perfusion to both temporal lobes, different from the patients of the control group (p less than 0.05). SPECT studies of HIV patients with no evidence of intracraneal space occupying pathology showed marked perfusion deficits. Patients with Parkinson's disease and the on-off syndrome studied during an on phase (under levodopa therapy) and on another occasion after withdrawal of levodopa (off) demonstrated a significant change in the uptake of [99mTc]-d,l-HM-PAO in the caudate nucleus (lower on off) and thalamus (higher on off). These findings justify the present interest in the functional evaluation of the brain of patients with dementia. [99mTc]-d,l-HM-PAO and regional cerebral blood flow (rCBF)/SPECT appear useful and highlight individual disorders of flow in a variety of neuropsychiatric conditions

  14. Analysis Of Factors Causing Delays On Harun Nafsi - Hm Rifadin Street In Samarinda East Kalimantan Maintenance Project

    Directory of Open Access Journals (Sweden)

    Fadli

    2017-12-01

    Full Text Available This study aims to identify analyze and describe the factors that affect the project maintenance delay on Harun Nafsi - HM. Rifadin Street in Samarinda East Kalimantan. This research uses qualitative research method by utilizing questionnaires. The 30 participating respondents consist of 14 project implementers and 16 field implementers. The data are analyzed by descriptive statistical technique factor analysis and linear regression analysis. The results show that the factors influencing the delay of maintenance project of Harun Nafis - HM Rifadin Street include 1 time factor and workmanship factor 2 human resources and natural factors 3 geographical conditions late approval plans change and labor strikes and 4 non-optimal working levels and changes in the scope of the project during the work are still ongoing. Based on multiple linear regression analysis coefficient of determination value of 0.824 is obtained. It means that the four factors studied affect 82.4 of project delays and the rest of 27.6 is influenced by other variables out of this study. The results of this study also indicate that the dominant factor for road maintenance project delays is the fourth factor of the factors mentioned. The effort that the contractor needs to undertake is not to expand the employment contract if the project is underway or the contractor does not have the capability to complete another project.

  15. Evolution of general surgical problems in patients with left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Morris, David S; Mauermann, William J; Park, Soon J; Zietlow, Scott P

    2012-11-01

    Left ventricular assist devices (LVADs) are increasingly used to treat patients with end-stage heart failure. These patients may develop acute noncardiac surgical problems around the time of LVAD implantation or, as survival continues to improve, chronic surgical problems as ambulatory patients remote from the LVAD implant. Previous reports of noncardiac surgical problems in LVAD patients included patients with older, first-generation devices and do not address newer, second-generation devices. We describe the frequency and management of noncardiac surgical problems encountered during LVAD support with these newer-generation devices to assist noncardiac surgeons involved in the care of patients with LVADs. We retrospectively reviewed the medical records of consecutive patients receiving LVADs at our institution. We collected data for any consultation by noncardiac surgeons within the scope of general surgery during LVAD support and subsequent treatment. Ninety-nine patients received implantable LVADs between 2003 and 2009 (first-generation, n = 19; second-generation, n = 80). Excluding intestinal hemorrhage, general surgical opinions were rendered for 34 patients with 49 problems, mostly in the acute recovery phase after LVAD implantation. Of those, 27 patients underwent 28 operations. Respiratory failure and intra-abdominal pathologies were the most common problems addressed, and LVAD rarely precluded operation. Patients with second-generation LVADs were more likely to survive hospitalization (P = .04) and develop chronic, rather than emergent, surgical problems. Patients with LVADs frequently require consultation from noncardiac surgeons within the scope of general surgeons and often require operation. Patients with second-generation LVADs are more likely to become outpatients and develop more elective surgical problems. Noncardiac surgeons will be increasingly involved in caring for patients with LVADs and should anticipate the problems unique to this patient

  16. Role of SPECT (HM-PAO, Tc99mRc) and ultrasound (TCD) in the instrumental diagnostic approach to the comprehension of reversible ischemic symptoms

    International Nuclear Information System (INIS)

    Liboni, W.; Baggiore, P.; Chianale, G.; Marta, G.; Castellano, G.; Cornaglia, G.

    1989-01-01

    The relation between variations of cerebral and acute neurologic events, followed by partial or total recovery, has been investigated with SPECT HM-PAO and with ultrasound (TRANSCRANIAL DOPPLER). (H.W.). 3 refs.; 2 figs.; 2 tabs

  17. [/sup 99m/Tc]-HM-PAO SPECT in Parkinson's disease

    International Nuclear Information System (INIS)

    Pizzolato, G.; Dam, M.; Borsato, N.; Saitta, B.; Da Col, C.; Perlotto, N.; Zanco, P.; Ferlin, G.; Battistin, L.

    1988-01-01

    Thirty-six patients affected by Parkinson's disease were studied using single photon emission computed tomography (SPECT) and [/sup 99m/Tc]-HM-PAO as a tracer. The scanning procedure was performed 16-24 h after discontinuation of specific therapy. Tracer activity ratios were determined in 10 pairs of cerebellar, cortical, and subcortical regions. Data were compared with those of 10 age-matched controls. Most of the regions examined did not show any relevant change between parkinsonian and control subjects. Notably, mean activity in striatal regions were similar in the two groups. Increased activity in caudate-putamen was found in patients who were on chronic DOPA therapy. Side-to-side asymmetries in the basal ganglia increased with the severity of the disease. Significant reductions of tracer uptake, from control values, were observed bilaterally in the parietal cortex. These deficits were more pronounced in patients with mental deterioration and in subjects who had been chronically treated with anticholinergic drugs. Parietal perfusion deficits in parkinsonian patients resemble those described in Alzheimer's dementia. These findings suggest that the heterogeneous alterations of regional cerebral blood flow (rCBF) in parkinsonian patients reflect the multifactorial pathophysiology of the disease

  18. Comparison of early versus delayed timing of left ventricular assist device implantation as a bridge-to-transplantation: An analysis of the UNOS dataset.

    Science.gov (United States)

    Kitada, Shuichi; Schulze, P Christian; Jin, Zhezhen; Clerkin, Kevin; Homma, Shunichi; Mancini, Donna M

    2016-01-15

    Placement of left ventricular assist devices (LVAD) as a bridge-to-heart transplantation (HTx) has rapidly expanded due to organ donor shortage. However, the timing of LVAD implantation is variable and it remains unclear if earlier implantation improves survival. We analyzed 14,187 adult candidates from the United Network of Organ Sharing database. Patients were classified by 3 treatment strategies including patients medically treated alone (MED, n=11,009), patients on LVAD support at listing (Early-LVAD, n=1588) and patients undergoing LVAD placement while awaiting HTx (Delayed-LVAD, n=1590). Likelihood of HTx and event-free survival were assessed in patients subcategorized by clinical strategies and UNOS status at listing. The device support strategy, despite the timing of placement, was not associated with increased likelihood of HTx compared to MED group. However, both LVAD implantation strategies showed better survival compared to MED group (Early-LVAD: HR 0.811 and 0.633, 95% CI 0.668-0.984 and 0.507-0.789, for 1A and 1B; p=0.034 and p<0.001, Delayed-LVAD: HR 0.553 and 0.696, 95% CI 0.415-0.736 and 0.571-0.847, for 1A and 1B; both p<0.001, respectively). Furthermore, there was no significant difference in survival between these LVAD implantation strategies in patients listed as 1B (p=0.500), although Early-LVAD implantation showed worse survival in patients listed as 1A (HR 1.467, 95% CI 1.076-2.000; p=0.015). LVAD support strategies offer a safe bridge-to-HTx. Those candidates who receive urgent upfront LVAD implantation for HTx, and improve to 1B status, would achieve competitive survival with those who receive elective LVAD implantation. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Cumulative vibratory indices and the H/M ratio of the soleus H-reflex: a quantitative study in control and spastic subjects

    NARCIS (Netherlands)

    Ongerboer de Visser, B. W.; Bour, L. J.; Koelman, J. H.; Speelman, J. D.

    1989-01-01

    Suppression of the soleus (Sol) H-reflex recruitment curve by Achilles tendon vibration and the ratio of maximum Sol H-reflex (Hmax) to maximum M-response (H/M ratio) have been studied by means of computer processing on the basis of peak-to-peak (P-P) and area values in 46 controls and in 16 spastic

  20. LEVERAGE OF THE COMMERCIAL SUCCESS OF FASHION TRADEMARKS ZARA AND H&M ON THE GLOBAL MARKET

    OpenAIRE

    Djakovič, Vesna

    2011-01-01

    Podjetje Zara in H&M sta vsekakor vsem poznani modni blagovni znamki, specializirani predvsem z oblačili, namenjeni v največji meri ženskam, vsekakor pa tudi moškim in otrokom. Glavni kupec ene kot druge znamke je mlajša populacija med 15 in 45 let. Obe znamki veljata za srednje kakovostni in s tem omogočata dosego nakupa širšemu segmentu. Njuni izdelki so primerni za študente, mlade družine, poslovneže ipd. Obe se poslužujeta različnih tržnih poti, tržnega komuniciranja in lastnih inovativni...

  1. Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: constant versus increasing pump speed: a pilot study

    DEFF Research Database (Denmark)

    Brassard, Patrice; Jensen, Annette S; Nordsborg, Nikolai

    2011-01-01

    with work rate would increase organ blood flow. Methods and Results- Invasively determined CO and leg blood flow and Doppler-determined cerebral perfusion were measured during 2 incremental cycle exercise tests on the same day in 8 patients provided with a HeartMate II LVAD. In random order, patients...

  2. Ambient hemolysis and activation of coagulation is different between HeartMate II and HeartWare left ventricular assist devices.

    Science.gov (United States)

    Birschmann, Ingvild; Dittrich, Marcus; Eller, Thomas; Wiegmann, Bettina; Reininger, Armin J; Budde, Ulrich; Strüber, Martin

    2014-01-01

    Thromboembolic and bleeding events in patients with a left ventricular assist device (LVAD) are still a major cause of complications. Therefore, the balance between anti-coagulant and pro-coagulant factors needs to be tightly controlled. The principle hypothesis of this study is that different pump designs may have an effect on hemolysis and activation of the coagulation system. Referring to this, the HeartMate II (HMII; Thoratec Corp, Pleasanton, CA) and the HeartWare HVAD (HeartWare International Inc, Framingham, MA) were investigated. For 20 patients with LVAD support (n = 10 each), plasma coagulation, full blood count, and clinical chemistry parameters were measured. Platelet function was monitored using platelet aggregometry, platelet function analyzer-100 system ( Siemens, Marburg, Germany), vasodilator-stimulated phosphoprotein phosphorylation assay, immature platelet fraction, platelet-derived microparticles, and von Willebrand diagnostic. Acquired von Willebrand syndrome could be detected in all patients. Signs of hemolysis, as measured by lactate dehydrogenase levels (mean, 470 U/liter HMII, 250 U/liter HVAD; p < 0.001), were more pronounced in the HMII patients. In contrast, D-dimer analysis indicated a significantly higher activation of the coagulation system in HVAD patients (mean, 0.94 mg/liter HMII, 2.01 mg/liter HVAD; p < 0.01). The efficacy of anti-platelet therapy using clopidogrel was not sufficient in more than 50% of the patients. Our results support the finding that all patients with rotary blood pumps suffered from von Willebrand syndrome. In addition, a distinct footprint of effects on hemolysis and the coagulation system can be attributed to different devices. As a consequence, the individual status of the coagulation system needs to be controlled in long-term patients. © 2013 Published by International Society for the Heart and Lung Transplantation on behalf of International Society for Heart and Lung Transplantation.

  3. A Subject-Based Aspect Report on Provision in Scotland's Colleges by HM Inspectors on Behalf of the Scottish Funding Council: Hospitality and Tourism

    Science.gov (United States)

    Her Majesty's Inspectorate of Education, 2010

    2010-01-01

    The HM Inspectorate of Education publication, "External quality arrangements for Scotland's colleges, September 2008," specifies that HMIE will produce a number of subject aspect reports over the four years 2008-12. These reports complement in a subject specific context the generic evaluations of learning and teaching in HMIE's reports…

  4. CBF tomograms with (/sup 99m/Tc-HM-PAO in patients with dementia (Alzheimer type and HIV) and Parkinson's disease--initial results

    Energy Technology Data Exchange (ETDEWEB)

    Costa, D.C.; Ell, P.J.; Burns, A.; Philpot, M.; Levy, R.

    1988-12-01

    We present preliminary data on the utility of functional brain imaging with (99mTc)-d,l-HM-PAO and single photon emission computed tomography (SPECT) in the study of patients with dementia of the Alzheimer type (DAT), HIV-related dementia syndrome, and the on-off syndrome of Parkinson's disease. In comparison with a group of age-matched controls, the DAT patients revealed distinctive bilateral temporal and posterior parietal deficits, which correlate with detailed psychometric evaluation. Patients with amnesia as the main symptom (group A) showed bilateral mesial temporal lobe perfusion deficits (p less than 0.02). More severely affected patients (group B) with significant apraxia, aphasia, or agnosia exhibited patterns compatible with bilateral reduced perfusion in the posterior parietal cortex, as well as reduced perfusion to both temporal lobes, different from the patients of the control group (p less than 0.05). SPECT studies of HIV patients with no evidence of intracraneal space occupying pathology showed marked perfusion deficits. Patients with Parkinson's disease and the on-off syndrome studied during an on phase (under levodopa therapy) and on another occasion after withdrawal of levodopa (off) demonstrated a significant change in the uptake of (99mTc)-d,l-HM-PAO in the caudate nucleus (lower on off) and thalamus (higher on off). These findings justify the present interest in the functional evaluation of the brain of patients with dementia. (99mTc)-d,l-HM-PAO and regional cerebral blood flow (rCBF)/SPECT appear useful and highlight individual disorders of flow in a variety of neuropsychiatric conditions.

  5. Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Khuansiri Narajeenron

    2017-04-01

    Full Text Available Audience: The audience for this classic team-based learning (cTBL session is emergency medicine residents, faculty, and students; although this topic is applicable to internal medicine and family medicine residents. Introduction: A left ventricular assist device (LVAD is a mechanical circulatory support device that can be placed in critically-ill patients who have poor left ventricular function. After LVAD implantation, patients have improved quality of life.1 The number of LVAD patients worldwide continues to rise. Left-ventricular assist device patients may present to the emergency department (ED with severe, life-threatening conditions. It is essential that emergency physicians have a good understanding of LVADs and their complications. Objectives: Upon completion of this cTBL module, the learner will be able to: 1 Properly assess LVAD patients’ circulatory status; 2 appropriately resuscitate LVAD patients; 3 identify common LVAD complications; 4 evaluate and appropriately manage patients with LVAD malfunctions. Method: The method for this didactic session is cTBL.

  6. Preoperative Right-Sided Cardiac Congestion Is Associated with Gastrointestinal Bleeding in Patients with Continuous-Flow Left Ventricular Assist Devices.

    Science.gov (United States)

    Tomizawa, Yutaka; Tanaka, Akiko; Kitahara, Hiroto; Sakuraba, Atsushi; Uriel, Nir; Jeevanandam, Valluvan; Ota, Takeyoshi

    2018-06-01

    Large scale data on preoperative risk stratification for gastrointestinal bleeding (GIB) following continuous-flow left ventricular assist device (CF-LVAD) implantation are scarce. To identify independent predictors for GIB following CF-LVAD implantation. We conducted a retrospective cohort study of consecutive 243 patients who underwent CF-LVAD implantation (HeartMateII) from January 2009 to March 2015 at the University of Chicago Medical Center. GIB was defined as the presence of overt bleeding or occult GIB with ≥ 2 g/dl drop in hemoglobin (Hgb) from recorded baseline values and hemoccult-positive stool. The preoperative and postoperative data were reviewed. Within a median follow-up duration of 408 (IQR 113-954) days, 83 (34%) patients developed GIB after a median of 149 (IQR 27-615) days after implantation of CF-LVAD. There were no significant differences between the groups of GIB and non-GIB with respect to preoperative demographics and comorbidity except for ethnicity. The source of bleeding was identified in 39 (47%) patients and arteriovenous malformation or submucosal streaming vessel was the most frequent cause of bleeding (18/39, 46%). Multivariate-adjusted analysis demonstrated preoperative central venous pressure (CVP) ≥ 18 mmHg (HR 3.56; 95% CI 1.16-10.9; p = 0.026), mean pulmonary artery pressure (mPA) ≥ 36 mmHg (HR 4.14; 95% CI 1.35-12.7; p = 0.013), and the presence of moderate/severe tricuspid valve disease (HR 1.01; 95% CI 1.01-3.86; p = 0.046) were associated with the risk of GIB. In this study, preoperative right-sided cardiac congestion (i.e., increased CVP, mPA and the presence of moderate/severe tricuspid valve disease) was associated with GIB in patients with CF-LVAD.

  7. Is green the new black? : the impact of sustainability on brand : Conscious Fashion, a case study on H&M

    OpenAIRE

    Ehrsam, Melanie Michelle

    2016-01-01

    The fast-fashion industry has been criticized along the years for its lack of environmental and social ethics. In this frame we find H&M, the world’s second largest fashion retailer. The Swedish fast-fashion retailer has set its goal towards making fashion sustainable and has launched in 2011 its sustainable clothing line “Conscious”. The present dissertation aims to discover the potential of sustainable fashion in changing consumers’ attitude towards the brand. For this matter...

  8. Purificación y caracterización parcial de una toxina (Hm3 del veneno de Hadruroides mauryi (Francke y Soleglad, 1980 (Scorpiones, Iuridae

    Directory of Open Access Journals (Sweden)

    Luz Velásquez

    2013-06-01

    Full Text Available Se ha purificado una toxina (Hm3 del veneno del escorpión Hadruroides mauryi, por cromatografía de intercambio iónico en CM-Sephadex C-25 con buffer acetato de amonio 0,05M, pH 7. La toxina produce contracción y parálisis en la extremidad inoculada de ratones albinos y se caracteriza por ser de naturaleza básica y tener un peso molecular de 4,5 kDa. Después de 45 minutos de ser inoculada en el músculo gastrocnemius de ratones albinos, Hm3 (30,4 µg aumenta los niveles plasmáticos de creatina kinasa desde 252,6 UI/L hasta 3779,3 UI/L y de lactato deshidrogenasa, desde 142,7 UI/L hasta 248,2 UI/L; igualmente incrementa los niveles de calcio intramuscular desde 34,1 nmoles hasta 69,3 nmoles. Esta toxina carece de actividad proteolítica y fosfolipásica.

  9. Anchoring in Destination-Therapy Left Ventricular Assist Device Decision Making: A Mechanical Turk Survey.

    Science.gov (United States)

    Paine, Arcadia M; Allen, Larry A; Thompson, Jocelyn S; McIlvennan, Colleen K; Jenkins, Amy; Hammes, Andrew; Kroehl, Miranda; Matlock, Daniel D

    2016-11-01

    People with end-stage heart failure may have to decide about destination-therapy left ventricular assist device (DT-LVAD). Individuals facing difficult decisions often rely on heuristics, such as anchoring, which predictably bias decision outcomes. We aimed to investigate whether showing a larger historical Heartmate XVE creates an anchoring effect, making the smaller Heartmate II (HMII) appear more favorable. With the use of Amazon Mechanical Turk, participants watched videos asking them to imagine themselves dying of end-stage heart failure, then were presented the option of LVAD as potentially life-prolonging therapy. Participants were randomized to a control group who were only shown the HMII device, and the intervention group who saw the XVE device before the HMII. Participants then completed surveys. A total of 487 participants completed the survey (control = 252; intervention = 235); 79% were affect likelihood of accepting the LVAD, it did affect device perception. This article highlights an important point with clinical implications: factors such as anchoring have the potential to inappropriately influence perceptions and decisions and should be carefully considered in research and practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Technetium-99m HM-PAO-SPECT study of regional cerebral perfusion in early Alzheimer's disease

    International Nuclear Information System (INIS)

    Perani, D.; Di Piero, V.; Vallar, G.

    1988-01-01

    Regional cerebral perfusion was evaluated by single photon emission computed tomography (SPECT) using technetium-99m hexamethylpropyleneamine oxime ([/sup 99m/Tc]HM-PAO) in sixteen patients with Alzheimer's disease (AD) in early clinical phase and in 16 healthy elderly controls. In all patients transmission computed tomography (TCT) and/or magnetic resonance imaging (MRI) did not show focal brain abnormalities. Relative to normal subjects, AD patients showed significant reductions in cortical/cerebellar activity ratio: cortical perfusion was globally depressed with the largest reductions in frontal and posterior temporo-parietal cortices. Asymmetries of relative perfusion between cerebral hemispheres were also demonstrated when language was affected or visuospatial functions were unevenly impaired. In patients with early AD, SPECT provides functional information to be compared with clinical and psychometric data

  11. Implant Strategy-Specific Changes in Symptoms in Response to Left Ventricular Assist Devices.

    Science.gov (United States)

    Lee, Christopher S; Gelow, Jill M; Chien, Christopher V; Hiatt, Shirin O; Bidwell, Julie T; Denfeld, Quin E; Grady, Kathleen L; Mudd, James O

    Although we know that the quality of life generally improves after left ventricular assist device (LVAD) implantation, we know little about how symptoms change in response to LVAD. The purpose of this study was to compare the changes in symptoms between bridge and destination therapy patients as part of a prospective cohort study. Physical (dyspnea and wake disturbances) and affective symptoms (depression and anxiety) were measured before LVAD and at 1, 3, and 6 months after LVAD. Multiphase growth modeling was used to capture the 2 major phases of change: initial improvements between preimplant and 1 month after LVAD and subsequent improvements between 1 and 6 months after LVAD. The sample included 64 bridge and 22 destination therapy patients as the preimplant strategy. Destination patients had worse preimplant dyspnea and wake disturbances, and they experienced greater initial improvements in these symptoms compared with bridge patients (all P .05). Destination patients had worse preimplant depression (P = .042) but experienced similar initial and subsequent improvements in depression in response to LVAD compared with bridge patients (both P > .05). Destination patients had similar preimplant anxiety (P = .279) but experienced less initial and greater subsequent improvements in anxiety after LVAD compared with bridge patients (both P < .05). There are many differences in the magnitude and timing of change in symptom responses to LVAD between bridge and destination therapy patients. Detailed information on changes in specific symptoms may better inform shared decision-making regarding LVAD.

  12. Bioethanol Production from Sugarcane Bagasse by a Novel Brazilian Pentose Fermenting Yeast Scheffersomyces shehatae UFMG-HM 52.2: Evaluation of Fermentation Medium

    Directory of Open Access Journals (Sweden)

    F. A. F. Antunes

    2014-01-01

    Full Text Available Bioconversion of hemicellulosic sugars into second generation (2G ethanol plays a pivotal role in the overall success of biorefineries. In this study, ethanol production performance of a novel xylose-fermenting yeast, Scheffersomyces shehatae UFMG-HM 52.2, was evaluated under batch fermentation conditions using sugarcane bagasse (SB hemicellulosic hydrolysate as carbon source. Dilute acid hydrolysis of SB was performed to obtain sugarcane bagasse hemicellulosic hydrolysate (SBHH. It was concentrated, detoxified, and supplemented with nutrients in different formulations to prepare the fermentation medium to the yeast evaluation performance. S. shehatae UFMG-HM 52.2 (isolated from Brazilian Atlantic rain forest ecosystem was used in fermentations carried out in Erlenmeyer flasks maintained in a rotator shaker at 30°C and 200 rpm for 72 h. The use of a fermentation medium composed of SBHH supplemented with 5 g/L ammonium sulfate, 3 g/L yeast extract, and 3 g/L malt extract resulted in 0.38 g/g of ethanol yield and 0.19 g L.h of volumetric productivity after 48 h of incubation time.

  13. Is exercise training safe and beneficial in patients receiving left ventricular assist device therapy?

    Science.gov (United States)

    Alsara, Osama; Perez-Terzic, Carmen; Squires, Ray W; Dandamudi, Sanjay; Miranda, William R; Park, Soon J; Thomas, Randal J

    2014-01-01

    Because a limited number of patients receive heart transplantation, alternative therapies, such as left ventricular assist device (LVAD) therapy, have emerged. Published studies have shown that LVAD implantation, by itself, improves exercise tolerance to the point where it is comparable to those with mild heart failure. The improvement in exercise capacity is maximally achieved 12 weeks after LVAD therapy and can continue even after explantation of the device. This effect varies, depending on the type of LVAD and exercise training. The available data in the literature on safety and benefits of exercise training in patients after LVAD implantation are limited, but the data that are available suggest that training trends to be safe and have an impact on exercise capacity in LVAD patients. Although no studies were identified on the role of cardiac rehabilitation programs in the management of LVAD patients, it appears that cardiac rehabilitation programs offer an ideal setting for the provision of supervised exercise training in this patient group.

  14. Inhaled Milrinone After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Haglund, Nicholas A; Burdorf, Adam; Jones, Tara; Shostrom, Valerie; Um, John; Ryan, Timothy; Shillcutt, Sasha; Fischer, Patricia; Cox, Zachary L; Raichlin, Eugenia; Anderson, Daniel R; Lowes, Brian D; Dumitru, Ioana

    2015-10-01

    Proven strategies to reduce right ventricular (RV) dysfunction after continuous-flow left ventricular assist device (CF-LVAD) implantation are lacking. We sought to evaluate the tolerability, feasibility, efficacy, and pharmacokinetics of inhaled milrinone (iMil) delivery after CF-LVAD implantation. We prospectively evaluated fixed-dose nebulized iMil delivered into a ventilator circuit for 24 hours in 10 postoperative CF-LVAD (Heartmate-II) patients. Tolerability (arrhythmias, hypotension, and hypersensitivity reaction), efficacy (hemodynamics), pharmacokinetics (plasma milrinone levels), and cost data were collected.Mean age was 56 ± 9 years, 90% were male, and mean INTERMACS profile was 2.5 ± 0.8. No new atrial arrhythmia events occurred, although 3 (30%) ventricular tachycardia (1 nonsustained, 2 sustained) events occurred. Sustained hypotension, drug hypersensitivity, death, or need for right ventricular assist device were not observed. Invasive mean pulmonary arterial pressure from baseline to during iMil therapy was improved (P = .017). Mean plasma milrinone levels (ng/mL) at baseline, and 1, 4, 8, 12, and 24 hours were 74.2 ± 35.4, 111.3 ± 70.9, 135.9 ± 41.5, 205.0 ± 86.7, 176.8 ± 61.3 187.6 ± 105.5, respectively. Reduced institutional cost was observed when iMil was compared with nitric oxide therapy over 24 hours ($165.29 vs $1,944.00, respectively). iMil delivery after CF-LVAD implantation was well tolerated, feasible, and demonstrated favorable hemodynamic, pharmacokinetic, and cost profiles. iMil therapy warrants further study in larger clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Anesthesia for gastrointestinal endoscopy in patients with left ventricular assist devices: Initial experience with 68 procedures

    Directory of Open Access Journals (Sweden)

    Basavana G Goudra

    2013-01-01

    Full Text Available Aims and Objectives: Continuous flow left ventricular assist devices (LVAD have emerged as a reliable treatment option for heart failure. Because of bleeding secondary to anticoagulation, these patients present frequently for gastrointestinal (GI endoscopy. The presently available literature on perioperative management of these patients is extremely limited and is primarily based upon theoretical principles. Materials and Methods: Perioperative records of patients with LVAD undergoing (GI endoscopy between 2008 and 2012 were reviewed. Patient, device and procedure specific information was analyzed. Results: A total of 105 LVADs were implanted, and 68 procedures were performed in 39 patients. The most common indication was GI bleed (48/68, with yearly risk of 8.57% per patient. A total of 63 procedures were performed under deep sedation, with five procedures requiring general anesthesia. Intra-procedure hypotension was managed by fluids and (or vasopressors/inotropes (phenylephrine, ephedrine or milrinone guided by plethysmographic waveform, non-invasive blood pressure (NIBP and LVADs pulsatility index (for HeartMate II/flow pulsatility (for HeartWare. No patient required invasive monitoring and both NIBP and pulse oximeter could be reliably used for monitoring (and guided management in all patients due to the presence of native heart′s pulsatile output. Conclusion: In the presence of residual heart function, with optimal device settings, non-invasive hemodynamic monitoring can be reliably used in these patients while undergoing GI endoscopy under general anesthesia or monitored anesthesia care. Transient hypotensive episodes respond well to fluids/vasopressors without the need of increasing device speed that can be detrimental.

  16. [Evaluation of the analyzer of hematology Beckman Coulter® HmX™ in the university hospital of Oran].

    Science.gov (United States)

    Zmouli, N; Moulasserdoun, K; Seghier, F

    2013-11-01

    The choice of an automaton of haematology is a determining stage, which has to take into account at the same time the quality of the results and the economic imperatives: workload, structure and organization of the laboratory. [corrected] It is in this spirit that we estimated during a period of 3 months the analyzer of haematology: the HmX™ Coulter with boatman of samples of the company Beckman. This automaton realizes the blood numeration, the formula leukocytic and the reticulocyte count. At first, we estimated the appropriate characteristics of device. Secondly, we estimated the relevance, the sensibility and the specificity of the alarms by comparing with the reference method, which is the optical microscopy. For that purpose, 125 blood smears resulting from service of haematology and from resuscitation were examined in optical microscopy. The technical tests were realized according to the recommendations of the International committee for evaluation of automatons of haematology. The analytical performances were satisfactory in particular the big interval of linearity and the absence of contamination. As regards the evaluation of the alarms system: rate of rejection is 63%, the sensibility 86%, the specificity 70%, the positive predictive value 80%, the negative predictive value 78% and the efficiency 80%. The alarms myelaemia and atypical lymphocytes were never sources of false negatives. The alarms erythroblasts and platelet aggregates did not engendered positive forgery. The blast cell alarm was responsible for a single case of false negative. The faithfulness of automaton is satisfactory: the absence of contamination, the big interval of linearity for the leukocytes, the red blood cells and the platelets as well as a good relevance of the alarms with regard to the anomalies found on the peripheral blood smear. From the user-friendliness and practicability point of view, the HmX™ Coulter was deeply appreciated. Copyright © 2013 Elsevier Masson SAS. All

  17. Impact of tricuspid valve surgery at the time of left ventricular assist device insertion on postoperative outcomes.

    Science.gov (United States)

    Dunlay, Shannon M; Deo, Salil V; Park, Soon J

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial. We searched SCOPUS, Web of Science, Ovid EMBASE, and Ovid MEDLINE (through May 10, 2014) for randomized controlled trials and observational studies comparing postoperative outcomes in patients treated with LVAD with concomitant tricuspid valve surgery (TVS) compared with LVAD alone. Six observational studies including 3,249 patients compared outcomes following LVAD + TVS versus LVAD. Four studies were single-center and most did not adjust for potential confounders. Addition of TVS prolonged cardiopulmonary bypass times by an average of 31 minutes (three studies, 95% CI 20-42). There was no difference in need for right ventricular assist device (six studies, HR 1.42, 95% CI 0.54-3.76), acute renal failure (four studies, HR 1.07, 95% CI 0.55-2.10), or early mortality (six studies, HR 1.28, 95% CI 0.78-2.08) in patients treated with LVAD + TVS versus LVAD alone. TVS prolongs cardiopulmonary bypass times, but available data demonstrate no significant association with early postoperative outcomes. However, differences in baseline risk of patients treated with TVS versus not limit our ability to draw conclusions.

  18. 99mTc-HM-PAO SPECT of epileptic patients showing focal paroxysm on electroencephalography

    International Nuclear Information System (INIS)

    Takaishi, Yasuko; Hashimoto, Kiyoshi; Fujino, Osamu; Kamayachi, Satoshi; Fujita, Takehisa; Enokido, Hisashi; Komatsuzaki, Hideki; Kawakami, Yasuhiko; Hirayama, Tsunenori

    1995-01-01

    The usefulness of 99m Tc-HM-PAO SPECT in diagnosing epilepsy was studied. The subjects were 33 epileptic patients, ranging in age from 5 years and 5 months to 28 years and 3 months, who showed focal paroxysm on electroencephalograms. Lowered accumulation site was found on SPECT in 19 patients. Four patients with abnormal findings on X-ray CT or MRI showed lowered accumulation and focal paroxysm at the same site. Of 29 patients with normal X-ray CT or MRI findings, 15 (52%) showed lowered accumulation. Five patients showed a focal paroxysm at the site of lowered accumulation. In 8 patients the focal paroxysm site was partly coincided with the accumulation site. In some patients the focal site predicted by the findings of clinical symptoms and the lowered accumulation site coincided. SPECT is therefore a useful method in diagnosing a focal site in epilepsy and considered to reflect the severity of disease. (Y.S.)

  19. Comparison of midlatitude ionospheric F region peak parameters and topside Ne profiles from IRI2012 model prediction with ground-based ionosonde and Alouette II observations

    Science.gov (United States)

    Gordiyenko, G. I.; Yakovets, A. F.

    2017-07-01

    The ionospheric F2 peak parameters recorded by a ground-based ionosonde at the midlatitude station Alma-Ata [43.25N, 76.92E] were compared with those obtained using the latest version of the IRI model (http://omniweb.gsfc.nasa.gov/vitmo/iri2012_vitmo.html). It was found that for the Alma-Ata (Kazakhstan) location, the IRI2012 model describes well the morphology of seasonal and diurnal variations of the ionospheric critical frequency (foF2) and peak density height (hmF2) monthly medians. The model errors in the median foF2 prediction (percentage deviations between the median foF2 values and their model predictions) were found to vary approximately in the range from about -20% to 34% and showed a stable overestimation in the median foF2 values for daytime in January and July and underestimation for day- and nighttime hours in the equinoctial months. The comparison between the ionosonde hmF2 and IRI results clearly showed that the IRI overestimates the nighttime hmF2 values for March and September months, and the difference is up to 30 km. The daytime Alma-Ata hmF2 data were found to be close to the IRI predictions (deviations are approximately ±10-15 km) in winter and equinoctial months, except in July when the observed hmF2 values were much more (from approximately 50-200 km). The comparison between the Alouette foF2 data and IRI predictions showed mixed results. In particular, the Alouette foF2 data showed a tendency to be overestimated for daytime in winter months similar to the ionosonde data; however, the overestimated foF2 values for nighttime in the autumn equinox were in disagreement with the ionosonde observations. There were large deviations between the observed hmF2 values and their model predictions. The largest deviations were found during winter and summer (up to -90 km). The comparison of the Alouette II electron density profiles with those predicted by the adapted IRI2012 model in the altitude range hmF2 of the satellite position showed a great

  20. Assessment of the arterial input curve for [99mTc]-d,l-HM-PAO by rapid octanol extraction

    DEFF Research Database (Denmark)

    Andersen, A R; Friberg, H; Lassen, N A

    1988-01-01

    The in vitro conversion of the lipophilic molecule [99mTc]-d,l-hexamethylpropyleneamine oxime [( 99mTc]-d,l-HM-PAO) to a hydrophilic form was studied in saline, plasma, and blood at 37 degrees C by paper chromatography and by octanol extraction. The octanol:saline ratio was 79.9. From this value...... and the corresponding octanol: plasma and octanol:blood partitioning values, an estimate of the transport of the lipophilic compound by various components of blood was made: 20% is carried in hemoglobin, 53% by the plasma proteins and 27% by the water phases of the red blood cell and plasma. Octanol extraction provided...

  1. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available putative [Entamoeba histolytica HM-1:IMSS] ... Length = 228 ... Query: 96 ... VRENMEDVISTCHLERNKDLVGVFDGHNG...DSAARIAATLLKQDTKNYTLLDDIHFIDLFN 155 ... VRENMEDVISTCHLERNKDLVGVFDGHNGDSAARIAATLLKQDTKNYTLLDDIHFIDLFN Sbjct: 1 ... VRENMEDVISTC

  2. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available tative [Entamoeba histolytica HM-1:IMSS] ... Length = 141 ... Query: 94 ... GFKTLSPYELNQMINSSKLDELFIIDVRYPY...EYNGGHVRSSMNISTETALYKELNKLFEI 153 ... GFKTLSPYELNQMINSSKLDELFIIDVRYPYEYNGGHVRSSMNISTETALYKELNKLFEI Sbjct: 1 ... GFKTLSPYELNQMINS

  3. Heavy metal accumulation in Pelargonium hortorum: Effects on growth and development

    OpenAIRE

    Orroño, DI; Lavado, RS

    2009-01-01

    Ornamental plants have been proposed for growing in heavy metal (HM) contaminated soils, and also for phytoremediation. We evaluated (1) biomass production and (2) HM accumulation in Pelargonium hortorum. Plants were grown for 16 weeks on HM (cadmium, chromium, copper, lead, nickel and zinc) enriched soils. Treatments were i) control, non-enriched soil, ii) medium concentration treatment, and iii) high concentration treatment. Four destructive harvests were carried out, and roots, stems, leav...

  4. Sex and intimacy among patients with implantable left-ventricular assist devices.

    Science.gov (United States)

    Marcuccilli, Linda; Casida, Jesus Jessie; Peters, Rosalind M; Wright, Susan

    2011-01-01

    Left-ventricular assist devices (LVADs) sustain and improve the quality of life of people living with an advanced stage of heart failure. Past research focused on the development and advancement of LVAD technology, complications, and survival rates. Limited research addressed the psychosocial aspects of living with an LVAD, yet research related to sexual functioning and intimacy is lacking. The purpose of this study was to explore and describe sex and intimacy among adults living with an LVAD. We used an interpretive phenomenological study to explore the experiences of adults living with a long-term implantable LVAD, including the effect of the LVAD on their intimate and sexual functioning. Semistructured interviews were conducted with 7 men and 2 women, 31 to 70 years of age, who had lived with the LVAD at home for at least 3 months. Interviews were audiorecorded and transcribed. The wholistic and selective approach by van Manen (Researching Lived Experience: Human Science for an Action Sensitive Pedagogy. Albany, NY: SUNY Press; 1990) guided the analysis and interpretation of the transcribed interviews. Data were organized and coded into words and phrases using qualitative software. Three themes emerged from the data: (a) improved sexual relations with LVAD, (b) sexual adjustment, and (c) nonsexual intimacy. The themes identified were consistent with the concept of normalcy from the theory of self-care. Participants reported that as the LVAD improved their overall health, their sexual functioning also improved. Participants also reported an increased sense of connectedness and intimacy with their partners even in the absence of sexual intercourse. Participants discussed ways in which they continued to develop intimate relationships even in the presence of limitations in structural and functional integrity. The knowledge derived from this study can be used as a guide for healthcare providers in counseling LVAD recipients on psychosocial and sexual health essential

  5. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available otein [Entamoeba histolytica HM-1:IMSS] ... Length = 113 ... Query: 129 SGHTSTATTHSISFTGTGNSIGKSNATNFKVT...GSIPTLDISKPTTNIKVRFIDGKQKVFK 188 ... SGHTSTATTHSISFTGTGNSIGKSNATNFKVTGSIPTLDISKPTTNIKVRFIDGKQKVFK Sbjct: 1 ... SGHTSTATTHSISFTGTGNSIGKSNATNFKVTGSIPTLDISKPTTNIKVRFIDGKQKVFK 60 ...

  6. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available t00003 [Entamoeba histolytica HM-1:IMSS] ... Length = 365 ... Query: 252 LPFEMKYQDLIKEIGKHKIYNHFMKIIIDRN...NVFNSLFKQIKHSEKWDRLFKIEFKHEQG 311 ... LPFEMKYQDLIKEIGKHKIYNHFMKIIIDRNNVFNSLFKQIKHSEKWDRLFKIEFKHEQG Sbjct: 1 ... LPFEM

  7. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available rotein [Entamoeba histolytica HM-1:IMSS] ... Length = 103 ... Query: 31 ... KVVRKPACNWSVEEDRKLLDAVNKFGKSRWVEIAEFVGSRSRKQCRERYINHIS...PMIDTS 90 ... KVVRKPACNWSVEEDRKLLDAVNKFGKSRWVEIAEFVGSRSRKQCRERYINHISPMIDTS Sbjct: 1 ... KVVRKPACNWSVEEDRKLLDAVNKFGKSRWVEIAEFVGSRSRKQCRERYINHISPMIDTS 60 ...

  8. FAKTOR- FAKTOR UTAMA PEMBENTUK PREFERENSI MASYARAKAT MENYIKAPI PELEBARAN JALAN H.M. SUWIGNYO TERHADAP PROSPEK ASET PRIBADI

    Directory of Open Access Journals (Sweden)

    Muhammad Hidayat

    2015-07-01

    Full Text Available The broadening of H.M. Suwignyo Street have triggered the street corridor expansion. The property's owners take benefit from the increasing of asset value. They will have choices to manage and determine preferences for the asset. This study was aimed to find out the prominent factors that determine asset's owner preferences toward street broadening consequences. In first phase, analysis is performed qualitatively to construct the quantitative instruments for next research. Data are gathered from observation and semi-structured interview to informans. Data are categorised and codified with the result as initial hypotheses, which indicate community preferences to employ the property asset. The result showed that the social strata of asset's owner; asset tangible and intangible value comprehension; economic motif; gentrification; and the intervening factor/ government role are the prominent factors

  9. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available yme, putative [Entamoeba histolytica ... HM-1:IMSS] ... Length = 145 ... Query: 7 ... IALMRLTADLKTMLTDPP...VGISSGPIDESNLYFWQATIAGPENSPFEGGLFELRLTFSDE 66 ... IALMRLTADLKTMLTDPPVGISSGPIDESNLYFWQATIAGPENSPF...EGGLFELRLTFSDE Sbjct: 1 ... IALMRLTADLKTMLTDPPVGISSGPIDESNLYFWQATIAGPENSPFEGGLFELRL

  10. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available rotein, putative [Entamoeba histolytica ... HM-1:IMSS] ... Length = 204 ... Query: 7 ... QWQKAQETIFVDWIND...TLKPDIIISNLEEDLKTGVNLILLVEKLTNKHCSEKIIENPKFR 66 ... QWQKAQETIFVDWINDTLKPDIIISNLEEDLKTGVNLILLVEK...LTNKHCSEKIIENPKFR Sbjct: 1 ... QWQKAQETIFVDWINDTLKPDIIISNLEEDLKTGVNLILLVEKLTNKHCSEK

  11. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available .t00007 [Entamoeba histolytica HM-1:IMSS] ... Length = 56 ... Query: 454 QTFEVERIVRKKIVHGNTSYLVKWKNYSSKDNTWETEDDIRT...KYGDLVDDFEKNQK 509 ... QTFEVERIVRKKIVHGNTSYLVKWKNYSSKDNTWETEDDIRTKYGDLVDDFEKNQK Sbjct: 1 ... QTFEVERIVRKKIVHGNTSYLVKWKNYSSKDNTWETEDDIRTKYGDLVDDFEKNQK 56

  12. A difficult decision: what should we do when malignant tumours are diagnosed in patients supported by left ventricular assist devices?

    Science.gov (United States)

    Smail, Hassiba; Pfister, Christian; Baste, Jean-Marc; Nafeh-Bizet, Catherine; Gay, Arnaud; Barbay, Virginie; Bessou, Jean-Paul; Peillon, Christophe; Litzler, Pierre-Yves

    2015-09-01

    Left ventricular assist devices (LVADs) are used as a bridge to heart transplantation. During the preimplantation or pretransplantation screening, malignant tumours can be discovered. Owing to the lack of guidelines, the management is difficult. We describe our perioperative approach and the patients' outcomes. Between 2006 and 2014, 55 patients underwent implantation of HeartMate II LVAD. Five were diagnosed with malignant tumours: 2 renal, 2 lung and 1 breast tumours. The renal tumours were diagnosed during the preimplantation screening. An LVAD was implanted in both followed by partial nephrectomies 8 and 9 months later. The lung cancers were diagnosed after device implantation, a left pulmonary segmentectomy and a right upper sleeve lobectomy were performed. The breast cancer was diagnosed few months after support and a tumourectomy with lymphadenectomy was performed. Tumour resection was performed successfully in all patients. Prior to surgery haemostasis, device and heart function were evaluated. During surgery, haemodynamics and anticoagulation were monitored. Reoperations were necessary to evacuate haemothorax after lobectomy and an abdominal haematoma post-nephrectomy. After discussion with oncologists, 3 patients were relisted for heart transplantation. Two were successfully transplanted 2 and 3 years after partial nephrectomy with an actual survival of 56 and 59 months after the cancer diagnosis. The follow-up revealed no cancer recurrences. Malignant tumours during support with LVAD can be successfully resected. A multidisciplinary evaluation in these high-risk patients is mandatory. After careful evaluation, regaining the patient's heart transplant candidacy is possible. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Use of [/sup 99m/Tc]-HM-PAO in the diagnosis of primary degenerative dementia

    International Nuclear Information System (INIS)

    Testa, H.J.; Snowden, J.S.; Neary, D.; Shields, R.A.; Burjan, A.W.; Prescott, M.C.; Northen, B.; Goulding, P.

    1988-01-01

    The clinical value of single photon emission computed tomography (SPECT) in the differential diagnosis of dementia due to cerebral atrophy was evaluated by comparing the pattern of distribution [/sup 99m/Tc]-HM-PAO in three dementing conditions. Imaging was carried out in 26 patients with suspected Alzheimer's disease, 14 with dementia of the frontal-lobe type, and 13 with progressive supranuclear palsy. Images were evaluated and reported without knowledge of clinical diagnosis with respect to regions of reduced uptake of tracer. Reduced uptake in the posterior cerebral hemispheres was characteristic of Alzheimer's disease, while selective anterior hemisphere abnormalities characterized both dementia of the frontal-lobe type and progressive supranuclear palsy. The latter conditions could be distinguished on the basis of the appearance of integrity of the rim of the frontal cortex. The technique has an important role in the differentiation of degenerative dementias

  14. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available GVPLDLINPPVLRIKVFEPLFIVGKENYAKLD 78 ... KSVQVFGKKKTAIAVCLCKEGKGMIRVNGVPLDLINPPVLRIKVFEPLFIVGKENYA...KLD Sbjct: 1 ... KSVQVFGKKKTAIAVCLCKEGKGMIRVNGVPLDLINPPVLRIKVFEPLFIVGKENYAKLD 60 ... Query... putative [Entamoeba histolytica HM-1:IMSS] ... Length = 139 ... Query: 19 ... KSVQVFGKKKTAIAVCLCKEGKGMIRVN

  15. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available 0063 [Entamoeba histolytica HM-1:IMSS] ... Length = 201 ... Query: 34 ... VGFIPTHQEIPYKEDPNYMFSKLNDVIPRTMNV...IINFYIPICVIAIISIYQKNIEKGLTV 93 ... VGFIPTHQEIPYKEDPNYMFSKLNDVIPRTMNVIINFYIPICVIAIISIYQKNIEKGLTV Sbjct...: 8 ... VGFIPTHQEIPYKEDPNYMFSKLNDVIPRTMNVIINFYIPICVIAIISIYQKNIEKGLTV 67 ... Query: 154

  16. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available Entamoeba histolytica HM-1:IMSS] ... Length = 170 ... Query: 24 ... VDAPTQKLRKPSVWATLRADDGGVITVLQLSKDKYTIGRSGNNDVI...ISNNVSCSRKQCSI 83 ... VDAPTQKLRKPSVWATLRADDGGVITVLQLSKDKYTIGRSGNNDVIISNNVSCSRKQCSI Sbjct: 21 ... ...VDAPTQKLRKPSVWATLRADDGGVITVLQLSKDKYTIGRSGNNDVIISNNVSCSRKQCSI 80 ... Query: 144 YSIIK

  17. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available Entamoeba histolytica HM-1:IMSS] ... Length = 219 ... Query: 344 EPAQADPENTYADGEGVEKCDAGKGPVKFTIHCVNKVGTSVPVTGAKFKVIIRSN...DGNEI 403 ... EPAQADPENTYADGEGVEKCDAGKGPVKFTIHCVNKVGTSVPVTGAKFKVIIRSNDGNEI Sbjct: 1 ... ... EPAQADPENTYADGEGVEKCDAGKGPVKFTIHCVNKVGTSVPVTGAKFKVIIRSNDGNEI 60 ... Query: 464 GVEG

  18. Compensating for Language Deficits in Amnesia II: H.M.’s Spared versus Impaired Encoding Categories

    Directory of Open Access Journals (Sweden)

    Chris Hadley

    2013-03-01

    Full Text Available Although amnesic H.M. typically could not recall where or when he met someone, he could recall their topics of conversation after long interference-filled delays, suggesting impaired encoding for some categories of novel events but not others. Similarly, H.M. successfully encoded into internal representations (sentence plans some novel linguistic structures but not others in the present language production studies. For example, on the Test of Language Competence (TLC, H.M. produced uncorrected errors when encoding a wide range of novel linguistic structures, e.g., violating reliably more gender constraints than memory-normal controls when encoding referent-noun, pronoun-antecedent, and referent-pronoun anaphora, as when he erroneously and without correction used the gender-inappropriate pronoun “her” to refer to a man. In contrast, H.M. never violated corresponding referent-gender constraints for proper names, suggesting that his mechanisms for encoding proper name gender-agreement were intact. However, H.M. produced no more dysfluencies, off-topic comments, false starts, neologisms, or word and phonological sequencing errors than controls on the TLC. Present results suggest that: (a frontal mechanisms for retrieving and sequencing word, phrase, and phonological categories are intact in H.M., unlike in category-specific aphasia; (b encoding mechanisms in the hippocampal region are category-specific rather than item-specific, applying to, e.g., proper names rather than words; (c H.M.’s category-specific mechanisms for encoding referents into words, phrases, and propositions are impaired, with the exception of referent gender, person, and number for encoding proper names; and (d H.M. overuses his intact proper name encoding mechanisms to compensate for his impaired mechanisms for encoding other functionally equivalent linguistic information.

  19. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available ve [Entamoeba histolytica HM-1:IMSS] ... Length = 179 ... Query: 8 ... ERSLMLNGKLYDSTVPELAHDRESCCEKIIDFNCERN...AQKRLEMLKDIVGSLGENSCILP 67 ... ERSLMLNGKLYDSTVPELAHDRESCCEKIIDFNCERNAQKRLEMLKDIVGSLGENSCILP Sbjct: ...1 ... ERSLMLNGKLYDSTVPELAHDRESCCEKIIDFNCERNAQKRLEMLKDIVGSLGENSCILP 60 ... Query: 128 E

  20. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available tamoeba histolytica HM-1:IMSS] ... Length = 219 ... Query: 344 EPAQADPENTYADGEGVEKCDAGKGPVKFTIHCVNKVGTAVPVTGAKFKVIIRSN...DGNEI 403 ... EPAQADPENTYADGEGVEKCDAGKGPVKFTIHCVNKVGTAVPVTGAKFKVIIRSNDGNEI Sbjct: 1 ... E...PAQADPENTYADGEGVEKCDAGKGPVKFTIHCVNKVGTAVPVTGAKFKVIIRSNDGNEI 60 ... Query: 464 GVEGGV

  1. Intraoperative bronchoscopic visualization of left ventricular assist device thrombus.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Modi, Sejal; Pappas, Pat; Tatooles, Antone

    2016-07-01

    Despite advancements in left ventricular assist device (LVAD) design and clinical management, device thrombosis remains a pertinent complication. Limited imaging makes precise visualization of clot location and shape very challenging. We report the usage of videobronchoscopic exploration of explanted LVADs for direct visualization of clot in two patients. This technique is a rapid and inexpensive means of improving our understanding of LVAD clot formation and may be useful in surgical exploration of inflow and outflow tracts during LVAD exchange. © The Author(s) 2015.

  2. Single photon emission computed tomography with [[sup 99]Tc]-HM-PAO and [[sup 123]I]-IBZM in Alzheimer's disease and dementia of frontal type; Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Frisoni, G.B.; Bianchetti, A.; Trabucchi, M. (Alzheimer' s Disease Care Unit, Ist. S. Cuore-FBF, Brescia (Italy)); Pizzolato, G.; Battistin, L. (Neurology Clinic, University Padua, Padua (Italy)); Chierichetti, F.; Ferlin, G. (Nuclear Medicine, Castelfranco Veneto Hospital, Treviso (Italy))

    1994-03-01

    Dementia of frontal type (DFT) is a fairly common degenerative disease distinct from Alzheimer's disease (AD), whose reportedly distinctive instrumental feature is frontal lobe hypoperfusion on SPECT. We evaluated the cortical dopaminergic system in 6AD, 5 DFT, and 6 control subjects with SPECT and both [[sup 99]Tc]-HM-PAO, a perfusion tracer, and [[sup 123]I]-IBZM, a D2 postsynaptic ligand. Both in AD and DFT patients, [[sup 99]Tc]-HM-PAO SPECT showed a relative frontal hypoperfusion. On the contrary, [[sup 123]I]-IBZM SPECT showed significantly reduced ligand uptake in superior frontal regions of DFT (0.89 [+-] 0.08 relative to control subjects) as compared to AD patients (0.97 [+-] 0.02; difference of means: 0.08, 95% confidence Interval 0.004 to 0.156; p = 0.041). Results suggest more marked involvement of the frontal cortical dopaminergic system in DFT than in AD patients. (au) (24 refs.).

  3. Cardiac Rotational Mechanics As a Predictor of Myocardial Recovery in Heart Failure Patients Undergoing Chronic Mechanical Circulatory Support: A Pilot Study.

    Science.gov (United States)

    Bonios, Michael J; Koliopoulou, Antigone; Wever-Pinzon, Omar; Taleb, Iosif; Stehlik, Josef; Xu, Weining; Wever-Pinzon, James; Catino, Anna; Kfoury, Abdallah G; Horne, Benjamin D; Nativi-Nicolau, Jose; Adamopoulos, Stamatis N; Fang, James C; Selzman, Craig H; Bax, Jeroen J; Drakos, Stavros G

    2018-04-01

    Impaired qualitative and quantitative left ventricular (LV) rotational mechanics predict cardiac remodeling progression and prognosis after myocardial infarction. We investigated whether cardiac rotational mechanics can predict cardiac recovery in chronic advanced cardiomyopathy patients. Sixty-three patients with advanced and chronic dilated cardiomyopathy undergoing implantation of LV assist device (LVAD) were prospectively investigated using speckle tracking echocardiography. Acute heart failure patients were prospectively excluded. We evaluated LV rotational mechanics (apical and basal LV twist, LV torsion) and deformational mechanics (circumferential and longitudinal strain) before LVAD implantation. Cardiac recovery post-LVAD implantation was defined as (1) final resulting LV ejection fraction ≥40%, (2) relative LV ejection fraction increase ≥50%, (iii) relative LV end-systolic volume decrease ≥50% (all 3 required). Twelve patients fulfilled the criteria for cardiac recovery (Rec Group). The Rec Group had significantly less impaired pre-LVAD peak LV torsion compared with the Non-Rec Group. Notably, both groups had similarly reduced pre-LVAD LV ejection fraction. By receiver operating characteristic curve analysis, pre-LVAD peak LV torsion of 0.35 degrees/cm had a 92% sensitivity and a 73% specificity in predicting cardiac recovery. Peak LV torsion before LVAD implantation was found to be an independent predictor of cardiac recovery after LVAD implantation (odds ratio, 0.65 per 0.1 degrees/cm [0.49-0.87]; P =0.014). LV rotational mechanics seem to be useful in selecting patients prone to cardiac recovery after mechanical unloading induced by LVADs. Future studies should investigate the utility of these markers in predicting durable cardiac recovery after the explantation of the cardiac assist device. © 2018 American Heart Association, Inc.

  4. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available protein LSm2, putative [Entamoeba ... histolytica HM-1:IMSS] ... Length = 69 ... Query: 5 ... SFFKTLIGKEVVVELKNDVI...ITGTLIAVDQMLNIKLNNLKCDATLFPQIQTMTDCFIRGN 64 ... SFFKTLIGKEVVVELKNDVIITGTLIAVDQMLNIKLNNLKC...DATLFPQIQTMTDCFIRGN Sbjct: 1 ... SFFKTLIGKEVVVELKNDVIITGTLIAVDQMLNIKLNNLKCDATLFPQIQTMTDCFIRGN 60 ...

  5. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available 2B delta subunit, putative [Entamoeba ... histolytica HM-1:IMSS] ... Length = 249 ... Query: 248 KASKLTQSSECI...PLIEENVKLLEHARTITVGMNNVRKFIFMKNQSIENIIATAQTVSSNI 307 ... KASKLTQSSECIPLIEENVKLLEHARTITVGM...NNVRKFIFMKNQSIENIIATAQTVSSNI Sbjct: 1 ... KASKLTQSSECIPLIEENVKLLEHARTITVGMNNVRKFIFM

  6. Novel elastic, lattice dynamics and thermodynamic properties of metallic single-layer transition metal phosphides: 2H-M 2P (Mo2P, W2P, Nb2P and Ta2P)

    Science.gov (United States)

    Yin, Jiuren; Wu, Bozhao; Wang, Yanggang; Li, Zhimi; Yao, Yuanpeng; Jiang, Yong; Ding, Yanhuai; Xu, Fu; Zhang, Ping

    2018-04-01

    Recently, there has been a surge of interest in the research of two-dimensional (2D) phosphides due to their unique physical properties and wide applications. Transition metal phosphides 2H-M 2Ps (Mo2P, W2P, Nb2P and Ta2P) show considerable catalytic activity and energy storage potential. However, the electronic structure and mechanical properties of 2D 2H-M 2Ps are still unrevealed. Here, first-principles calculations are employed to investigate the lattice dynamics, elasticity and thermodynamic properties of 2H-M 2Ps. Results show that M 2Ps with lower stiffness exhibit remarkable lateral deformation under unidirectional loads. Due to the largest average Grüneisen parameter, single-layer Nb2P has the strongest anharmonic vibrations, resulting in the highest thermal expansion coefficient. The lattice thermal conductivities of Ta2P, W2P and Nb2P contradict classical theory, which would predict a smaller thermal conductivity due to the much heavier atom mass. Moreover, the calculations also demonstrate that the thermal conductivity of Ta2P is the highest as well as the lowest thermal expansion, owing to its weak anharmonic phonon scattering and the lowest average Grüneisen parameter. The insight provided by this study may be useful for future experimental and theoretical studies concerning 2D transition metal phosphide materials.

  7. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available 2B delta subunit, putative [Entamoeba ... histolytica HM-1:IMSS] ... Length = 249 ... Query: 363 KASKLTQSSECI...PL------------------------XXXXXXXXXXXXATAQTVSSNI 398 ... KASKLTQSSECIPL ... ... ... ATAQTVSSNI Sbjct: 1 ... KASKLTQSSECIPLIEENVKLLEHARTITVGMNNVRKFIFM

  8. FLUENT calculations of the hydrogen distribution in a containment during the OECD-NEA THAI HM-2 experiment

    International Nuclear Information System (INIS)

    Visser, D.C.; Komen, E.M.J.; Houkema, M.; Siccama, N.B.; Kyttaelae, Juha; Huhtanen, Risto; Takasuo, Eveliina

    2009-01-01

    Hydrogen may be released into the containment atmosphere of a nuclear power plant during a severe accident. Locally, high hydrogen concentrations may be reached that can possibly cause fast deflagration or even detonation and put the integrity of the containment at risk. Therefore, the distribution and mixing of hydrogen is an important safety issue for nuclear power plants. Computer codes can be applied to predict the hydrogen distribution in the containment within the course of a hypothetical severe accident and get an estimate of the local hydrogen concentration in the various zones of the containment. In this way the risk associated with the hydrogen safety issue can be determined, and safety related measurements and procedures could be assessed. In order to validate the existing computer codes in the context of hydrogen distribution in the containment of a nuclear power plant, experimental benchmark studies have been performed in the German Thermal-hydraulics, Hydrogen, Aerosols and Iodine (THAI) facility in the framework of the OECD-NEA THAI project. In order to demonstrate the capabilities of the commercial Computational Fluid Dynamics (CFD) code FLUENT the THAI HM-2 test was simulated independently by NRG and VTT. In the first phase of the HM-2 test a stratified hydrogen rich light gas layer was established in the upper part of the THAI containment. In the second phase steam was injected at a lower position inducing a rising plume that gradually dissolved the stratified hydrogen-rich layer from below. Thermo-dynamic phenomena like natural convection, mixing, condensation, heat transfer and distribution in different zones that are expected in severe accidents are involved. The calculated results by NRG and VTT (on hydrogen concentration, temperature, pressure and flow velocity) are compared to the experimental results. The most important differences between the CFD model of NRG and VTT are the computational mesh, condensation model and treatment of the solid

  9. Normal Control Study of Cerebral Blood Flow by 99mTc HM-PAO SPECT

    International Nuclear Information System (INIS)

    Koong, Sung Soo; Moon, Dae Hyuk; Lee, Bum Woo; Lee, Kyung Han

    1989-01-01

    Regional cerebral perfusion was evaluated in 15 normal controls by single photon emission computed tomography using 99m Tc HM-PAO. For quantitative analysis, 13 pairs of homologous region of interest (ROI) were drawn on three transverse slices matching the vascular territories and cerebral cortices, and normal values of 3 semiquantitative indices including 'Right to left ratio' (R/L ratio), 'Regional index' (RI), and 'Region to cerebellum ratio (R/cbll ratio) were calculated. Mean values of R/L ratios of homologous regions were ranged from 0.985 to 1.023, and mean ± 2 s.d. of all regions did not exceed 11% of mean. Significant difference of Rls (mean count per voxel of a ROI/mean count per voxel of total ROls) between regions were found (p<0.001) with highest values in occipital cortex and cerebellum. After attenuation correction, Rls in deep gray, cranial portion of anterior cerebral artery and vascular territories in the 2nd slice increased significantly (p<0.05-0.001) hut vise versa in other ROIs. Region to cerebellum ratios also showed regional difference similar to Rls.

  10. The Achilles' heel of left ventricular assist device therapy: right ventricle.

    Science.gov (United States)

    Ranganath, Neel K; Smith, Deane E; Moazami, Nader

    2018-06-01

    Many patients suffer from either persistent right ventricular failure (RVF) at the time of left ventricular assist device (LVAD) or have ongoing symptoms consistent with RVF during chronic mechanical circulatory support. The lack of long-term right ventricular assist devices (RVADs) has limited the impact that mechanical circulatory support can provide to patients with biventricular failure. We aim to review the entire spectrum of RVF in patients receiving LVADs and reflect on why this entity remains the Achilles' heel of LVAD therapy. In the early postoperative period, LVAD implantation reduces right ventricle (RV) afterload, but RV dysfunction may be exacerbated secondary to increased venous return. With prolonged therapy, the decreased RV afterload leads to improved RV contractile function. Bayesian statistical models outperform previously published preoperative risk scores by considering inter-relationships and conditional probabilities amongst independent variables. Various echocardiographic parameters and the pulmonary artery pulsatility index have shown promise in predicting post-LVAD RVF. Recent publications have delineated the emergence of 'delayed' RVF. Several devices are currently being investigated for use as RVADs. Post-LVAD RVF depends on the RV's ability to adapt to acute hemodynamic changes imposed by the LVAD. Management options are limited due to the lack of an easily implantable, chronic-use RVAD.

  11. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    Science.gov (United States)

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  12. Exercise physiology, testing, and training in patients supported by a left ventricular assist device.

    Science.gov (United States)

    Loyaga-Rendon, Renzo Y; Plaisance, Eric P; Arena, Ross; Shah, Keyur

    2015-08-01

    The left ventricular assist device (LVAD) is an accepted treatment alternative for the management of end-stage heart failure. As we move toward implantation of LVADs in less severe cases of HF, scrutiny of functional capacity and quality of life becomes more important. Patients demonstrate improvements in exercise capacity after LVAD implantation, but the effect is less than predicted. Exercise training produces multiple beneficial effects in heart failure patients, which would be expected to improve quality of life. In this review, we describe factors that are thought to participate in the persistent exercise impairment in LVAD-supported patients, summarize current knowledge about the effect of exercise training in LVAD-supported patients, and suggest areas for future research. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  13. Review of the Contribution of the Scottish Science Centres Network to Formal and Informal Science Education: Report of Follow-Through Visits by HM Inspectorate of Education--June 2009

    Science.gov (United States)

    Her Majesty's Inspectorate of Education, 2009

    2009-01-01

    In 2006, the Scottish Executive's Enterprise, Transport and Lifelong Learning Department (SEETLLD) asked HM Inspectorate of Education (HMIE) to carry out a review of the four Scottish science centres--Glasgow Science Centre (GSC), Our Dynamic Earth (ODE) in Edinburgh, Satrosphere Science Centre in Aberdeen, and Sensation Science Centre in Dundee.…

  14. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.

    Science.gov (United States)

    Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David

    2017-10-01

    To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.

  15. The miRNA Expression Profile in Acute Myocardial Infarct Using Sheep Model with Left Ventricular Assist Device Unloading

    Directory of Open Access Journals (Sweden)

    Xiaoqian Yan

    2017-01-01

    Full Text Available This study attempted to establish miRNA expression profiles in acute myocardial infarct (AMI sheep model with left ventricular assist device (LVAD unloading. AMI was established in sheep model and FW-II type axial flow pump was implanted to maintain continuous unloading for 3 days. The cardiomyocyte survival, inflammatory cell infiltration, and myocardial fibrosis were detected by tissue staining, and cardiomyocyte apoptosis was detected by TUNEL assay. High throughput sequencing technique was used to detect miRNA expression in cardiomyocytes and to establish miRNA expression profile. The Gene Ontology (GO and Kyoto Encyclopedia of Genes and Genomes (KEGG analyses were established. miRNA sequencing results identified 152 known mature miRNAs and 1582 new mature miRNAs. The unloading and control groups differentially expressed genes, of which RT-PCR verified oar-miR-19b and oar-miR-26a. The GO and KEGG pathway annotation and enrichment established that the regulating functions and signaling pathways of these miRNAs were closely related to cardiovascular diseases (CVD. In this study, LVAD effectively reduced the cell death degree of cardiomyocyte in MI. The established miRNA expression profiles of AMI and LVAD intervention in this study suggest that the expression profile could be used to explore the unknown miRNA and the regulatory mechanisms involved in AMI.

  16. Cost-effectiveness of left ventricular assist devices for patients with end-stage heart failure: analysis of the French hospital discharge database.

    Science.gov (United States)

    Tadmouri, Abir; Blomkvist, Josefin; Landais, Cécile; Seymour, Jerome; Azmoun, Alexandre

    2018-02-01

    Although left ventricular assist devices (LVADs) are currently approved for coverage and reimbursement in France, no French cost-effectiveness (CE) data are available to support this decision. This study aimed at estimating the CE of LVAD compared with medical management in the French health system. Individual patient data from the 'French hospital discharge database' (Medicalization of information systems program) were analysed using Kaplan-Meier method. Outcomes were time to death, time to heart transplantation (HTx), and time to death after HTx. A micro-costing method was used to calculate the monthly costs extracted from the Program for the Medicalization of Information Systems. A multistate Markov monthly cycle model was developed to assess CE. The analysis over a lifetime horizon was performed from the perspective of the French healthcare payer; discount rates were 4%. Probabilistic and deterministic sensitivity analyses were performed. Outcomes were quality-adjusted life years (QALYs) and incremental CE ratio (ICER). Mean QALY for an LVAD patient was 1.5 at a lifetime cost of €190 739, delivering a probabilistic ICER of €125 580/QALY [95% confidence interval: 105 587 to 150 314]. The sensitivity analysis showed that the ICER was mainly sensitive to two factors: (i) the high acquisition cost of the device and (ii) the device performance in terms of patient survival. Our economic evaluation showed that the use of LVAD in patients with end-stage heart failure yields greater benefit in terms of survival than medical management at an extra lifetime cost exceeding the €100 000/QALY. Technological advances and device costs reduction shall hence lead to an improvement in overall CE. © 2017 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.

  17. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available tein [Entamoeba histolytica HM-1:IMSS] ... Length = 131 ... Query: 3 ... FEYLDHPADVILHSWGQNIIEAFENAAAGMFNFMSDLT...NIDATSYEEALVKFLDSWLCIF 62 ... FEYLDHPADVILHSWGQNIIEAFENAAAGMFNFMSDLTNIDATSYEEALVKFLDSWLCIF Sbjct...: 1 ... FEYLDHPADVILHSWGQNIIEAFENAAAGMFNFMSDLTNIDATSYEEALVKFLDSWLCIF 60 ... Query: 123 DQTHIHILLDI 133 ... DQTHIHILLDI Sbjct: 121 DQTHIHILLDI 131

  18. A comparison of the health status and psychological distress of partners of patients with a left ventricular assist device versus an implantable cardioverter defibrillator

    DEFF Research Database (Denmark)

    Brouwers, Corline; Caliskan, Kadir; de Jonge, Nicolaas

    2014-01-01

    (F = 10.71, p = .001) but poorer mental health status (F = 14.82, p depression scores compared to ICD partners (F = 3.68, p = .05) at 6 months follow-up, also in adjusted analyses. There was no significant difference between groups on anxiety. CONCLUSION: Caregivers of LVAD......OBJECTIVE: To examine if the caregiving for patients with a left ventricular assist device (LVAD) is related to a poorer health status and more distress compared to patients with an implantable cardioverter defibrillator (ICD). BACKGROUND: Partners distress may influence patient outcomes...... and is therefore an important aspect in the care of LVAD and ICD patients. METHODS: Multi-center prospective observational study with 6 months follow-up of 33 LVAD partners (27% men; mean age = 54 ± 10 years) and 414 ICD partners (22% men; mean age = 60 ± 12 years). RESULTS: LVAD partners reported better physical...

  19. TET1-Mediated Hydroxymethylation Facilitates Hypoxic Gene Induction in Neuroblastoma

    Directory of Open Access Journals (Sweden)

    Christopher J. Mariani

    2014-06-01

    Full Text Available The ten-eleven-translocation 5-methylcytosine dioxygenase (TET family of enzymes catalyzes the conversion of 5-methylcytosine (5-mC to 5-hydroxymethylcytosine (5-hmC, a modified cytosine base that facilitates gene expression. Cells respond to hypoxia by inducing a transcriptional program regulated in part by oxygen-dependent dioxygenases that require Fe(II and α-ketoglutarate. Given that the TET enzymes also require these cofactors, we hypothesized that the TETs regulate the hypoxia-induced transcriptional program. Here, we demonstrate that hypoxia increases global 5-hmC levels, with accumulation of 5-hmC density at canonical hypoxia response genes. A subset of 5-hmC gains colocalize with hypoxia response elements facilitating DNA demethylation and HIF binding. Hypoxia results in transcriptional activation of TET1, and full induction of hypoxia-responsive genes and global 5-hmC increases require TET1. Finally, we show that 5-hmC increases and TET1 upregulation in hypoxia are HIF-1 dependent. These findings establish TET1-mediated 5-hmC changes as an important epigenetic component of the hypoxic response.

  20. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available 6, putative [Entamoeba histolytica ... HM-1:IMSS] ... Length = 122 ... Query: 26 ... LQRRKGMIRVNGVPLDLINPPVLRIKVFEPLFIVGKENYA...KLDLKIRVTGGGQVAQAYAI 85 ... LQRRKGMIRVNGVPLDLINPPVLRIKVFEPLFIVGKENYAKLDLKIRV...TGGGQVAQAYAI Sbjct: 1 ... LQRRKGMIRVNGVPLDLINPPVLRIKVFEPLFIVGKENYAKLDLKIRVTGGGQVAQAYAI 60 ... Query: 146 YR 147 ... YR Sbjct: 121 YR 122

  1. Tour of the stands at the UK@CERN industrial exhibition with the Director-General and H.E. Mr Simon Featherstone, HM Ambassador to Switzerland, hosted by Mrs. Jan Fillingham MBE, Head of Exhibitions, BEAMA

    CERN Multimedia

    Claudia Marcelloni

    2006-01-01

    Tour of the stands at the UK@CERN industrial exhibition with the Director-General and H.E. Mr Simon Featherstone, HM Ambassador to Switzerland, hosted by Mrs. Jan Fillingham MBE, Head of Exhibitions, BEAMA

  2. On the condition of UO{sub 2} nuclear fuel irradiated in a PWR to a burn-up in excess of 110 MWd/kgHM

    Energy Technology Data Exchange (ETDEWEB)

    Restani, R.; Horvath, M. [Paul Scherrer Institut, CH-5232, Villigen PSI (Switzerland); Goll, W. [AREVA GmbH, P.O. Box 1109, DE-91001 Erlangen (Germany); Bertsch, J.; Gavillet, D.; Hermann, A. [Paul Scherrer Institut, CH-5232, Villigen PSI (Switzerland); Martin, M., E-mail: matthias.martin@psi.ch [Paul Scherrer Institut, CH-5232, Villigen PSI (Switzerland); Walker, C.T. [The Grange, 66 High Street, Swinderby, Lincoln LN6 9LU (United Kingdom)

    2016-12-01

    Post-irradiation examination results are presented for UO{sub 2} fuel from a PWR fuel rod that had been irradiated to an average burn-up of 105 MWd/kgHM and showed high fission gas release of 42%. The radial distribution of xenon and the partitioning of fission gas between bubbles and the fuel matrix was investigated using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and electron probe microanalysis. It is concluded that release from the fuel at intermediate radial positions was mainly responsible for the high fission gas release. In this region thermal release had occurred from the high burn-up structure (HBS) at some point after the sixth irradiation cycle. The LA-ICP-MS results indicate that gas release had also occurred from the HBS in the vicinity of the pellet periphery. It is shown that the gas pressure in the HBS pores is well below the pressure that the fuel can sustain. - Highlights: • Gas retention measured by laser ablation induction coupled plasma mass spectrometry. • Thermal release from the high burn structure responsible for high gas release. • At a pellet burn-up of 115 MWd/kgHM the high burn-up structure is still evolving. • The gas pressure in HBS pores is well below the pressure that the fuel can sustain.

  3. Left ventricular assist device management in patients chronically supported for advanced heart failure.

    Science.gov (United States)

    Cowger, Jennifer; Romano, Matthew A; Stulak, John; Pagani, Francis D; Aaronson, Keith D

    2011-03-01

    This review summarizes management strategies to reduce morbidity and mortality in heart failure patients supported chronically with implantable left ventricular assist devices (LVADs). As the population of patients supported with long-term LVADs has grown, patient selection, operative technique, and patient management strategies have been refined, leading to improved outcomes. This review summarizes recent findings on LVAD candidate selection, and discusses outpatient strategies to optimize device performance and heart failure management. It also reviews important device complications that warrant close outpatient monitoring. Managing patients on chronic LVAD support requires regular patient follow-up, multidisciplinary care teams, and frequent laboratory and echocardiographic surveillance to ensure optimal outcomes.

  4. Right heart failure and "failure to thrive" after left ventricular assist device: clinical predictors and outcomes.

    Science.gov (United States)

    Baumwol, Jay; Macdonald, Peter S; Keogh, Anne M; Kotlyar, Eugene; Spratt, Phillip; Jansz, Paul; Hayward, Christopher S

    2011-08-01

    This study determined predictors of early post-operative right heart failure (RHF) and its consequences, as well as predictors of those who clinically thrive longer term after insertion of a continuous-flow left ventricular assist device (LVAD). Pre-operative and latest follow-up data were analyzed for 40 consecutive patients who received third-generation centrifugal-flow LVADs. RHF was defined using previously described criteria, including post-operative inotropes, pulmonary vasodilator use, or right-sided mechanical support. Patients were also categorized according to clinical outcomes after LVAD insertion. LVADs were implanted as a bridge to transplantation (BTT) in 33 patients and as destination therapy in 7. Before LVAD implant, 22 patients were Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) level 1, and 17 were at level 2. Temporary mechanical assistance was present in 50% of the cohort at LVAD implantation. The 6-month survival/progression to transplant was 92.5%. Average LVAD support time was 385 days (range, 21-1,011 days). RHF developed postoperatively in 13 of 40 patients (32.5%). RHF patients had more severe pre-operative tricuspid incompetence than non-RHF patients. The BTT patients with evidence of RHF had poorer survival to transplant (6 of 11 [54.5%]) than those without RHF (20 of 22 [90.9%]), p = 0.027). There were no other hemodynamic or echocardiographic predictors of short-term RHF. After LVAD, 22 of the 40 patients (55%) thrived clinically. For BTT patients, 20 of 21 (95%) of those who thrived progressed to transplant or were alive at latest follow-up vs 6 of 12 (50%) of those who failed to thrive (FTT; p thrived. Early post-operative RHF results in poorer survival/progression to transplantation for BTT patients and is predicted by greater pre-operative tricuspid incompetence. The most important predictor for those who will clinically thrive longer-term after LVAD insertion is younger age. Crown Copyright © 2011

  5. Fission gas release behaviour of a 103 GWd/t{sub HM} fuel disc during a 1200 °C annealing test

    Energy Technology Data Exchange (ETDEWEB)

    Noirot, J., E-mail: jean.noirot@cea.fr [CEA, DEN, DEC, Cadarache, F-13108 St. Paul Lez Durance (France); Pontillon, Y. [CEA, DEN, DEC, Cadarache, F-13108 St. Paul Lez Durance (France); Yagnik, S. [EPRI, P.O. Box 10412, Palo Alto, CA 94303-0813 (United States); Turnbull, J.A. [Independent Consultant (United Kingdom); Tverberg, T. [IFE, P.O. Box 173, NO-1751 Halden (Norway)

    2014-03-15

    Within the Nuclear Fuel Industry Research (NFIR) program, several fuel variants, in the form of thin circular discs, were irradiated in the Halden Boiling Water Reactor (HBWR) to a range of burn-ups ∼100 GWd/t{sub HM}. The design of the assembly was similar to that used in other HBWR programs: the assembly contained several rods with fuel discs sandwiched between Mo discs, which limited temperature gradients within the fuel discs. One such rod contained standard grain UO{sub 2} discs (3D grain size = 18 μm) reaching a burn-up of 103 GWd/t{sub HM}. After the irradiation, the gas release upon rod puncturing was measured to be 2.9%. Detailed characterizations of one of these irradiated UO{sub 2} discs, using electron probe microanalysis (EPMA), scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS), were performed in a CEA Cadarache hot laboratory. Examination revealed the high burn-up structure (HBS) formation throughout the whole of the disc, also the fission gas distribution within this HBS, with a very high proportion of the gas in the HBS bubbles. A sibling disc was submitted to a temperature transient up to 1200 °C in the out-of-pile (OOP) annealing test device “Merarg” at a relatively low temperature ramp rate (0.2 °C/s). In addition to the total gas release during this annealing test, the release peaks throughout the temperature range were monitored. The fuel was then characterized with the same microanalysis techniques as before the annealing test to investigate the effects of this test on the microstructure of the fuel and on the fission gases. It provided valuable insights into fission gas localization and the release behaviour in UO{sub 2} fuel with high burn-up structure (HBS)

  6. Die etiek van HM Kuitert na aanleiding van sy boek Suicide - wat is er tegen? Selfdoding in moreel perspectief

    Directory of Open Access Journals (Sweden)

    R. M. Naudé

    1988-01-01

    Full Text Available The ethics of HM Kuitert according to his book entitled. Suicide - wat is er tegen? Selfdoding in moreel perspektief According to several publications Kuitert is criticised as a humanist. This paper tests his view on suicide to this accusation. It is found that Kuitert accepts teleology and solidarity as norms for his ethics and uses it as a method for his arguments against suicide. His goal is to offer an ethic which is acceptable for the Christian and the non-Christian. This results in outonomy with less emphasis on the theological argument against suicide. The result of this study is that the ethics of Kuitert cannot be described as mere humanism. Outonomy is judged as a form of theonomy.

  7. Ramp Study Hemodynamics, Functional Capacity, and Outcome in Heart Failure Patients with Continuous-Flow Left Ventricular Assist Devices

    DEFF Research Database (Denmark)

    Jung, Mette H; Gustafsson, Finn; Houston, Brian

    2016-01-01

    Ramp studies-measuring changes in cardiac parameters as a function of serial pump speed changes (revolutions per minute [rpm])-are increasingly used to evaluate function and malfunction of continuous-flow left ventricular assist devices (CF-LVADs). We hypothesized that ramp studies can predict...... patients (HeartMate II, Thoratec Corporation, Pleasanton, CA). Functional status was evaluated in 70% (31/44); average 6 minute walk test (6MWT) was 312 ± 220 min, New York Heart Association (NYHA) I-II/III-IV (70/30%) and activity scores very low-low/moderate-very high (55/45%). Decrease in pulmonary...

  8. Calculation of the ALMA Risk of Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Loforte, Antonio; Montalto, Andrea; Musumeci, Francesco; Amarelli, Cristiano; Mariani, Carlo; Polizzi, Vincenzo; Lilla Della Monica, Paola; Grigioni, Francesco; Di Bartolomeo, Roberto; Marinelli, Giuseppe

    2018-05-08

    Right ventricular failure after continuous-flow left ventricular assist device (LVAD) implantation is still an unsolved issue and remains a life-threatening event for patients. We undertook this study to determine predictors of the patients who are candidates for isolated LVAD therapy as opposed to biventricular support (BVAD). We reviewed demographic, echocardiographic, hemodynamic, and laboratory variables for 258 patients who underwent both isolated LVAD implantation and unplanned BVAD because of early right ventricular failure after LVAD insertion, between 2006 and 2017 (LVAD = 170 and BVAD = 88). The final study patients were randomly divided into derivation (79.8%, n = 206) and validation (20.1%, n = 52) cohorts. Fifty-seven preoperative risk factors were compared between patients who were successfully managed with an LVAD and those who required a BVAD. Nineteen variables demonstrated statistical significance on univariable analysis. Multivariable logistic regression analysis identified destination therapy (odds ratio [OR] 2.0 [1.7-3.9], p = 0.003), a pulmonary artery pulsatility index right ventricle/left ventricle end-diastolic diameter ratio >0.75 (OR 2.7 [1.5-5.5], p = 0.001), an right ventricle stroke work index 17 (OR 3.5 [1.9-6.9], p the major predictors of the need for BVAD. Using these data, we propose a simple risk calculator to determine the suitability of patients for isolated LVAD support in the era of continuous-flow mechanical circulatory support devices.

  9. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available EHA1 253.m00087 >1gntA 1 549 4 539 e-171 ... gb|EAL51411.1| hydroxylamine reductase, ...putative [Entamoeba histolytica HM-1:IMSS] ... gb|EAL44619.1| hydroxylamine reductase, putative ...

  10. Exertional Angina Due To Fused Aortic Bioprosthesis During Left Ventricular Assist Device Support: Two Cases and Review of the Literature.

    Science.gov (United States)

    Bonios, Michael J; Selzman, Craig H; Gilbert, Edward M; McKellar, Stephen H; Koliopoulou, Antigoni; Strege, Jennifer L; Nativi, Jose N; Fang, James C; Stehlik, Josef; Drakos, Stavros G

    We present the case of two patients with idiopathic dilated cardiomyopathy and moderate aortic valve regurgitation that were treated with a bioprosthetic valve at the time of the left ventricular assist device (LVAD) implantation. A few months later, patients revealed partial recovery in the left ventricle systolic function. Both patients, during the LVAD turndown protocol, reported the onset of chest pain. The transthoracic echocardiography revealed the presence of a new transaortic pressure gradient. We confirmed the presence of a fused bioprosthetic valve by further performing a transesophageal echocardiogram and a left and right heart catheterization. Replacement of aortic valve at the time of an LVAD implantation constitutes a challenging case. Although a mechanical valve is contraindicated due to the increased thromboembolic risk, selecting a bioprosthetic valve increases the risk of valve leaflets fusion. The consequences of this phenomenon should be acknowledged in LVAD patients undergoing aortic valve replacement with a bioprosthetic, especially under the view of LVAD explantation for those revealing myocardial recovery under mechanical unloading.

  11. Endocarditis in left ventricular assist device

    Science.gov (United States)

    Thyagarajan, Braghadheeswar; Kumar, Monisha Priyadarshini; Sikachi, Rutuja R; Agrawal, Abhinav

    2016-01-01

    Summary Heart failure is one of the leading causes of death in developed nations. End stage heart failure often requires cardiac transplantation for survival. The left ventricular assist device (LVAD) has been one of the biggest evolvements in heart failure management often serving as bridge to transplant or destination therapy in advanced heart failure. Like any other medical device, LVAD is associated with complications with infections being reported in many patients. Endocarditis developing secondary to the placement of LVAD is not a frequent, serious and difficult to treat condition with high morbidity and mortality. Currently, there are few retrospective studies and case reports reporting the same. In our review, we found the most common cause of endocarditis in LVAD was due to bacteria. Both bacterial and fungal endocarditis were associated with high morbidity and mortality. In this review we will be discussing the risk factors, organisms involved, diagnostic tests, management strategies, complications, and outcomes in patients who developed endocarditis secondary to LVAD placement. PMID:27672540

  12. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  13. The role of implantable cardioverter defibrillators in patients bridged to transplantation with a continuous-flow left ventricular assist device: A propensity score matched analysis.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Mancini, Donna M; Yuzefpolskaya, Melana; Demmer, Ryan T; Dizon, Jose M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-06-01

    Implantable cardioverter defibrillators (ICDs) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). It is unclear whether patients with a continuous-flow LVAD (CF-LVAD) derive the same benefit. We sought to determine if the presence of an ICD provided a mortality benefit during CF-LVAD support as a bridge to transplantation. Patients were identified in the United Network for Organ Sharing (UNOS) registry who underwent LVAD implantation as bridge to transplantation between May 2004 and April 2014, with follow-up through June 2014. Primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary end-points included freedom from delisting while on CF-LVAD support and incidence of transplantation. The study cohort comprised 2,990 patients, and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (hazard ratio [HR] = 1.20; 95% confidence interval [CI], 0.66-2.17; p = 0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR = 1.11; 95% CI, 0.60-2.05; p = 0.74). There was no increased risk of delisting owing to being too sick for patients with an ICD (HR = 1.08; 95% CI, 0.63-1.86; p = 0.78). Likewise, the probability of transplantation was similar (HR = 1.05; 95% CI, 0.87-1.27; p = 0.62). Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  14. The effect of heart failure and left ventricular assist device treatment on right ventricular mechanics: a computational study.

    Science.gov (United States)

    Park, Jun I K; Heikhmakhtiar, Aulia Khamas; Kim, Chang Hyun; Kim, Yoo Seok; Choi, Seong Wook; Song, Kwang Soup; Lim, Ki Moo

    2018-05-22

    Although it is important to analyze the hemodynamic factors related to the right ventricle (RV) after left ventricular assist device (LVAD) implantation, previous studies have focused only on the alteration of the ventricular shape and lack quantitative analysis of the various hemodynamic parameters. Therefore, we quantitatively analyzed various hemodynamic parameters related to the RV under normal, heart failure (HF), and HF incorporated with continuous flow LVAD therapy by using a computational model. In this study, we combined a three-dimensional finite element electromechanical model of ventricles, which is based on human ventricular morphology captured by magnetic resonance imaging (MRI) with a lumped model of the circulatory system and continuous flow LVAD function in order to construct an integrated model of an LVAD implanted-cardiovascular system. To induce systolic dysfunction, the magnitude of the calcium transient function under HF condition was reduced to 70% of the normal value, and the time constant was reduced by 30% of the normal value. Under the HF condition, the left ventricular end systolic pressure decreased, the left ventricular end diastolic pressure increased, and the pressure in the right atrium (RA), RV, and pulmonary artery (PA) increased compared with the normal condition. The LVAD therapy decreased the end-systolic pressure of the LV by 41%, RA by 29%, RV by 53%, and PA by 71%, but increased the right ventricular ejection fraction by 52% and cardiac output by 40%, while the stroke work was reduced by 67% compared with the HF condition without LVAD. The end-systolic ventricular tension and strain decreased with the LVAD treatment. LVAD enhances CO and mechanical unloading of the LV as well as those of the RV and prevents pulmonary hypertension which can be induced by HF.

  15. Modification of self-concept in patients with a left-ventricular assist device: an initial exploration.

    Science.gov (United States)

    Marcuccilli, Linda; Casida, Jesus; Peters, Rosalind M

    2013-09-01

    To explore how patients with left-ventricular assist devices (LVAD) meet the health-deviation requisite of modifying self-concept to accept this form of treatment and restore normalcy. LVAD are becoming a standard option to improve the quality of life for patients with advanced heart failure. Past research focused on technology issues and survival rates, but limited research has addressed the effect of LVADs on patients' perceptions of self. Orem's theory of self-care provides a framework to investigate how patients manage threats to self-concept to safely live with such a device. Hermeneutic phenomenology based on van Manen's method. Data were collected using semi-structured interviews. Data saturation was achieved with nine participants (seven men; two women), 31-70 years of age who lived with a LVAD at home for at least three months. Thematic analysis was ongoing, and final themes were consensually validated. Two themes constructed from the data were consistent with the requisite of modifying self-concept. First, Having a LVAD means living. Participants described they 'feel alive again', and they 'had the rest of [their] lives that they didn't have before'. The second theme: A desire to be 'normal' in public, arose from participants descriptions of how the LVAD brought unwanted attention to them and that their appearance was 'shocking' to others. Participants accepted the LVAD as necessary to live making it easier for them to modify their self-concept and accept the changes to their bodies and daily lives. Attaining a sense of normalcy was more difficult in public and required additional lifestyle modifications. Findings advance self-care knowledge in LVAD management and can heighten nurses' awareness about self-concept as a vital component for maintenance of health and well-being. © 2013 Blackwell Publishing Ltd.

  16. ORF Alignment: EHA1 [GENIUS II[Archive

    Lifescience Database Archive (English)

    Full Text Available EHA1 8.m00410 >1gntA 1 549 4 539 e-171 ... gb|EAL51411.1| hydroxylamine reductase, pu...tative [Entamoeba histolytica HM-1:IMSS] ... gb|EAL44619.1| hydroxylamine reductase, putative ...

  17. UO2 fuel behaviour at rod burn-ups up to 105 MWd/kgHM. A review of 10 years of high burn-up examinations commissioned by AREVA NP

    International Nuclear Information System (INIS)

    Goll, W.; Hoffmann, P.B.; Hellwig, C.; Sauser, W.; Spino, J.; Walker, C.T.

    2007-01-01

    Irradiation experience gained on fuel rods with burn-ups greater than 60 MWd/kgHM irradiated in the Nuclear Power Plant Goesgen, Switzerland, is described. Emphasis is placed on the fuel behaviour, which has been analysed by hot cell examinations at the Institute for Transuranium Elements and the Paul-Scherrer-Institute. Above 60 MWd/kgHM, the so-called high burn-up structure (HBS) forms and the fission gas release increases with burn-up and rod power. Examinations performed in the outer region of the fuel revealed that most if not all of the fission gas created was retained in the HBS, even at 25% porosity. Furthermore, the HBS has a relatively low swelling rate, greatly increased plasticity, and its thermal conductivity is higher than expected from the porosity. The post-irradiation examinations showed that the HBS has no detrimental effects on the performance of stationary irradiated PWR fuel irradiated to the high burn-ups that can be achieved with 5 wt% U-235 enrichment. On the contrary, the HBS results in fuel performance that is generally better than it would have been if the HBS had not formed. (orig.)

  18. Right ventricular dysfunction following continuous flow left ventriccular assist device placement in 51 patients: predicators and outcomes

    Directory of Open Access Journals (Sweden)

    Neragi-Miandoab Siyamek

    2012-06-01

    Full Text Available Abstract Background Right ventricular (RV dysfunction following implantation of a left ventricular assist device (LVAD is a serious condition and is associated with increased mortality. Methods The aim of the study is to investigate the significance of pre-existing RV dysfunction, tricuspid valve (TV insufficiency, and the severity of septal deviation following LVAD implantation on RV dysfunction, as well as the outcome and short-term complications in 51 patients from June 2006 to August 2010. Student t test was used to compare the data and estimate the p value. Results Mean age was 55.1 ± 13, with a male to female ratio of 3.25. The 30-day mortality was 13.7% (7/51 patients, and the overall mortality was 23.5% (12/51 patients. Meanwhile, 21 patients (21/51; 41.2% have undergone orthotopic heart transplantation. The mean time of support was 314.5±235 days with a median of 240 days at the time of closing this study. Echocardiographic evaluation of RV function pre- and post-implantation of an LVAD demonstrated septal deviation towards the left ventricle in immediate postoperative phase, which correlated with acute RV dysfunction (p = 0.002. Preoperative RV dysfunction was a significant predictor of postoperative right heart dysfunction following implantation of an LVAD (p = 0.001. Conclusion Preoperative RV dysfunction is a predictor of RV failure in LVAD patients. The adjustment of septal deviation through gradual increase of the LVAD flow can prevent the acute RV dysfunction following LVAD placement.

  19. Pre- and post-operative risk factors associated with cerebrovascular accidents in patients supported by left ventricular assist device. -Single center's experience in japan-.

    Science.gov (United States)

    Nakajima, Ikutaro; Kato, Tomoko S; Komamura, Kazuo; Takahashi, Ayako; Oda, Noboru; Sasaoka, Taro; Asakura, Masanori; Hashimura, Kazuhiko; Kitakaze, Masafumi

    2011-01-01

    Cerebrovascular accident (CVA) is a major adverse event following left ventricular assist device (LVAD) surgery. This study investigates pre- and post-operative factors associated with CVA in this population. A total of 118 consecutive patients who underwent LVAD surgery at our institution between April 1994 and April 2009 were retrospectively reviewed. Clinical characteristics, hemodynamic data, and laboratory indexes associated with CVA after LVAD surgery were analyzed. In total, 57 (48.3%) patients developed CVA 133.5 ± 184.7 days after surgery. The combination of baseline heart disease, type of LVAD surgery, mean right atrial pressure (mRA), serum total bilirubin and total protein concentration, and right ventricular end-diastolic dimension (RVEDd) was associated with CVA at any time after LVAD surgery, with a discriminant probability of 718%. With regard to CVA development later than 3 months after surgery, the combination of mRA and RVEDd before surgery [odds ratio (OR), 1.24, 1.20; 95% confidential interval (CI), 1.07-1.42, 1.06-1.34; P = 0.004, P = 0.006, respectively], positive blood culture, and C-reactive protein after surgery (OR, 7.66, 2.19; 95%CI, 1.50-39.0, 1.47-3.25; P = 0.015, P < 0.0001, respectively) was associated with CVA with a discriminant probability of 85.9%. Patients' general condition including malnutrition, in addition to device selection, contributed to overall CVA development after surgery. In the chronic phase after surgery, pre-LVAD right heart failure and post-LVAD systemic infection were highly associated with CVA development.

  20. Continuous-flow cardiac assistance: effects on aortic valve function in a mock loop.

    Science.gov (United States)

    Tuzun, Egemen; Rutten, Marcel; Dat, Marco; van de Vosse, Frans; Kadipasaoglu, Cihan; de Mol, Bas

    2011-12-01

    As the use of left ventricular assist devices (LVADs) to treat end-stage heart failure has become more widespread, leaflet fusion--with resul-tant aortic regurgitation--has been observed more frequently. To quantitatively assess the effects of nonpulsatile flow on aortic valve function, we tested a continuous-flow LVAD in a mock circulatory system (MCS) with an interposed valve. To mimic the hemodynamic characteristics of LVAD patients, we utilized an MCS in which a Jarvik 2000 LVAD was positioned at the base of a servomotor-operated piston pump (left ventricular chamber). We operated the LVAD at 8000 to 12,000 rpm, changing the speed in 1000-rpm increments. At each speed, we first varied the outflow resistance at a constant stroke volume, then varied the stroke volume at a constant outflow resistance. We measured the left ventricular pressure, aortic pressure, pump flow, and total flow, and used these values to compute the change, if any, in the aortic duty cycle (aortic valve open time) and transvalvular aortic pressure loads. Validation of the MCS was demonstrated by the simulation of physiologic pressure and flow waveforms. At increasing LVAD speeds, the mean aortic pressure load steadily increased, while the aortic duty cycle steadily decreased. Changes were consistent for each MCS experimental setting, despite variations in stroke volume and outflow resistance. Increased LVAD flow results in an impaired aortic valve-open time due to a pressure overload above the aortic valve. Such an overload may initiate structural changes, causing aortic leaflet fusion and/or regurgitation. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Renal Function and Outcomes With Use of Left Ventricular Assist Device Implantation and Inotropes in End-Stage Heart Failure: A Retrospective Single Center Study.

    Science.gov (United States)

    Verma, Sean; Bassily, Emmanuel; Leighton, Shane; Mhaskar, Rahul; Sunjic, Igor; Martin, Angel; Rihana, Nancy; Jarmi, Tambi; Bassil, Claude

    2017-07-01

    Left ventricular assist device (LVAD) and inotrope therapy serve as a bridge to transplant (BTT) or as destination therapy in patients who are not heart transplant candidates. End-stage heart failure patients often have impaired renal function, and renal outcomes after LVAD therapy versus inotrope therapy have not been evaluated. In this study, 169 patients with continuous flow LVAD therapy and 20 patients with continuous intravenous inotrope therapy were analyzed. The two groups were evaluated at baseline and at 3 and 6 months after LVAD or inotrope therapy was started. The incidence of acute kidney injury (AKI), need for renal replacement therapy (RRT), BTT rate, and mortality for 6 months following LVAD or inotrope therapy were studied. Results between the groups were compared using Mann-Whitney U test and Chi-square with continuity correction or Fischer's exact at the significance level of 0.05. Mean glomerular filtration rate (GFR) was not statistically different between the two groups, with P = 0.471, 0.429, and 0.847 at baseline, 3 and 6 months, respectively. The incidence of AKI, RRT, and BTT was not statistically different. Mortality was less in the inotrope group (P < 0.001). Intravenous inotrope therapy in end-stage heart failure patients is non-inferior for mortality, incidence of AKI, need for RRT, and renal function for 6-month follow-up when compared to LVAD therapy. Further studies are needed to compare the effectiveness of inotropes versus LVAD implantation on renal function and outcomes over a longer time period.

  2. Efficacy of second generation lithotriptors: a multicenter comparative study of 2,206 extracorporeal shock wave lithotripsy treatments with the Siemens Lithostar, Dornier HM4, Wolf Piezolith 2300, Direx Tripter X-1 and Breakstone lithotriptors

    NARCIS (Netherlands)

    Bierkens, A. F.; Hendrikx, A. J.; de Kort, V. J.; de Reyke, T.; Bruynen, C. A.; Bouve, E. R.; Beek, T. V.; Vos, P.; Berkel, H. V.

    1992-01-01

    Extracorporeal shock wave lithotripsy (ESWL) has become the treatment of choice for urinary calculi. The good results of the first generation Dornier HM3 lithotriptor stimulated the development of second generation machines. A multicenter trial is presented involving the Siemens Lithostar, Dornier

  3. "Pseudo" Faraday cage: a solution for telemetry link interaction between a left ventricular assist device and an implantable cardioverter defibrillator.

    Science.gov (United States)

    Jacob, Sony; Cherian, Prasad K; Ghumman, Waqas S; Das, Mithilesh K

    2010-09-01

    Patients implanted with left ventricular assist devices (LVAD) may have implantable cardioverter defibrillators (ICD) implanted for sudden cardiac death prevention. This opens the possibility of device-device communication interactions and thus interferences. We present a case of such interaction that led to ICD communication failure following the activation of an LVAD. In this paper, we describe a practical solution to circumvent the communication interference and review the communication links of ICDs and possible mechanisms of ICD-LVAD interactions.

  4. Impact of Tricuspid Valve Surgery at the Time of Left Ventricular Assist Device Insertion on Postoperative Outcomes

    OpenAIRE

    Dunlay, Shannon M.; Deo, Salil V.; Park, Soon J.

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial.

  5. Mechanical unloading of the failing human heart fails to activate the protein kinase B/Akt/glycogen synthase kinase-3beta survival pathway.

    Science.gov (United States)

    Razeghi, Peter; Bruckner, Brian A; Sharma, Saumya; Youker, Keith A; Frazier, O H; Taegtmeyer, Heinrich

    2003-01-01

    Left ventricular assist device (LVAD) support of the failing human heart improves myocyte function and increases cell survival. One potential mechanism underlying this phenomenon is activation of the protein kinase B (PKB)/Akt/glycogen synthase kinase-3beta (GSK-3beta) survival pathway. Left ventricular tissue was obtained both at the time of implantation and explantation of the LVAD (n = 11). Six patients were diagnosed with idiopathic dilated cardiomyopathy, 4 patients with ischemic cardiomyopathy and 1 patient with peripartum cardiomyopathy. The mean duration of LVAD support was 205 +/- 35 days. Myocyte diameter and phosphorylation of ERK were used as indices for reverse remodeling. Transcript levels of genes required for the activation of PKB/Akt (insulin-like growth factor-1, insulin receptor substrate-1) were measured by quantitative RT-PCR. In addition, we measured the relative activity of PKB/Akt and GSK-3beta, and assayed for molecular and histological indices of PKB/Akt activation (cyclooxygenase mRNA levels and glycogen levels). Myocyte diameter and phosphorylation of ERK decreased with LVAD support. In contrast, none of the components of the PKB/Akt/GSK-3beta pathway changed significantly with mechanical unloading. The PKB/Akt/GSK-3beta pathway is not activated during LVAD support. Other signaling pathways must be responsible for the improvement of cellular function and cell survival during LVAD support. Copyright 2003 S. Karger AG, Basel

  6. Risk Stratification of Patients With Current Generation Continuous-Flow Left Ventricular Assist Devices Being Bridged to Heart Transplantation.

    Science.gov (United States)

    Guha, Ashrith; Nguyen, Duc; Cruz-Solbes, Ana S; Amione-Guerra, Javier; Schutt, Robert C; Bhimaraj, Arvind; Trachtenberg, Barry H; Park, Myung H; Graviss, Edward A; Gaber, Osama; Suarez, Erik; Montane, Eva; Torre-Amione, Guillermo; Estep, Jerry D

    Patients bridged to transplant (BTT) with continuous-flow left ventricular assist devices (CF-LVADs) have increased in the past decade. Decision support tools for these patients are limited. We developed a risk score to estimate prognosis and guide decision-making. We included heart transplant recipients bridged with CF-LVADs from the United Network for Organ Sharing (UNOS) database and divided them into development (2,522 patients) and validation cohorts (1,681 patients). Univariate and multivariate Cox proportional hazards models were performed. Variables that independently predicted outcomes (age, African American race, recipient body mass index [BMI], intravenous [IV] antibiotic use, pretransplant dialysis, and total bilirubin) were assigned weight using linear transformation, and risk scores were derived. Patients were grouped by predicted posttransplant mortality: low risk (≤ 38 points), medium risk (38-41 points), and high risk (≥ 42 points). We performed Cox proportional hazards analysis on wait-listed CF-LVAD patients who were not transplanted. Score significantly discriminated survival among the groups in the development cohort (6.7, 12.9, 20.7; p = 0.001), validation cohort (6.4, 10.1, 13.6; p assist device (LVAD) BTT risk score that effectively identifies CF-LVAD patients who are at higher risk for worse outcomes after heart transplant. This score may help physicians weigh the risks of transplantation in patients with CF-LVAD.

  7. Role of ventricular assist therapy for patients with heart failure and restrictive physiology: Improving outcomes for a lethal disease.

    Science.gov (United States)

    Grupper, Avishay; Park, Soon J; Pereira, Naveen L; Schettle, Sarah D; Gerber, Yariv; Topilsky, Yan; Edwards, Brooks S; Daly, Richard C; Stulak, John M; Joyce, Lyle D; Kushwaha, Sudhir S

    2015-08-01

    Restrictive cardiomyopathy (RCM) patients have poor prognosis due to progressive heart failure characterized by impaired ventricular filling of either or both ventricles. The goal of this study was to evaluate the outcome of end-stage RCM patients after left ventricular assist device (LVAD) implantation and to determine factors that may be associated with improved survival. This investigation is a retrospective study of prospectively collected data that include 28 consecutive patients with end-stage RCM who received continuous-flow LVADs at the Mayo Clinic, Rochester, Minnesota. Outcome was assessed by survival with LVAD support until heart transplantation or all-cause mortality. The mean follow-up time post-LVAD implantation was 448 ± 425 days. The mean hospitalization time was 29 ± 19 days and was complicated mainly by post-operative right ventricular (RV) failure requiring short-term medical support. The short-term in-hospital mortality was 14%. Ten patients underwent heart transplantation with 100% survival post-transplant during the follow-up period. One-year survival for patients with LVADs without transplantation was 64%, and was not significantly different between amyloidosis and non-amyloidosis patients. Larger left ventricle (LV) end-diastolic and end-systolic dimensions were significantly associated with improved survival rates (RR = 0.94 and 0.95, p < 0.05, respectively), and left ventricular end-diastolic diameter (LVEDD) ≤46 mm was associated with increased mortality post-LVAD implantation. LVAD is a feasible, life-saving therapy for end-stage heart failure related to RCM, especially as a bridge to transplant and in patients with larger LV dimensions. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Comparative analysis of von Willebrand factor profiles after implantation of left ventricular assist device and total artificial heart.

    Science.gov (United States)

    Reich, H J; Morgan, J; Arabia, F; Czer, L; Moriguchi, J; Ramzy, D; Esmailian, F; Lam, L; Dunhill, J; Volod, O

    2017-08-01

    Essentials Bleeding is a major source of morbidity during mechanical circulatory support. von Willebrand factor (VWF) multimer loss may contribute to bleeding. Different patterns of VWF multimer loss were seen with the two device types. This is the first report of total artificial heart associated VWF multimer loss. Background Bleeding remains a challenge during mechanical circulatory support and underlying mechanisms are incompletely understood. Functional von Willebrand factor (VWF) impairment because of loss of high-molecular-weight multimers (MWMs) produces acquired von Willebrand disease (VWD) after left ventricular assist device (LVAD). Little is known about VWF multimers with total artificial hearts (TAHs). Here, VWF profiles with LVADs and TAHs are compared using a VWD panel. Methods VWD evaluations for patients with LVAD or TAH (2013-14) were retrospectively analyzed and included: VWF activity (ristocetin cofactor, VWF:RCo), VWF antigen (VWF:Ag), ratio of VWF:RCo to VWF:Ag, and quantitative VWF multimeric analysis. Results Twelve patients with LVADs and 12 with TAHs underwent VWD evaluation. All had either normal (47.8%) or elevated (52.2%) VWF:RCo, normal (26.1%) or elevated (73.9%) VWF:Ag and 50.0% were disproportional (ratio ≤ 0.7). Multimeric analysis showed abnormal patterns in all patients with LVADs: seven with high MWM loss; five with highest MWM loss. With TAH, 10/12 patients had abnormal patterns: all with highest MWM loss. High MWM loss correlated with presence of LVAD and highest MWM loss with TAH. Increased low MWMs were detected in 22/24. Conclusion Using VWF multimeric analysis, abnormalities after LVAD or TAH were detected that would be missed with measurements of VWF level alone: loss of high MWM predominantly in LVAD, loss of highest MWM in TAH, and elevated levels of low MWM in both. This is the first study to describe TAH-associated highest MWM loss, which may contribute to bleeding. © 2017 International Society on Thrombosis and

  9. Propuesta de un modelo de un sistema de gestión de calidad, basado en la Norma ISO 9001:2008 en el Hotel HM Internacional

    OpenAIRE

    Riera Peralta, Patricia; Naranjo Navarrete, Pierina

    2013-01-01

    El propósito de la presente tesis es diseñar un Modelo de un Sistema de Gestión de Calidad basado en Norma ISO 9001-2008, para que el hotel HM Internacional pueda competir con otros servicios hoteleros en diferentes partes del mundo, ofreciendo un servicio de calidad que aumente la satisfacción del cliente, incremente la rentabilidad del negocio y disminuya los costos. La tesis comienza planteando el problema del área de recepción, describiendo la metodología de la investigación a seguir pa...

  10. IIIB or not IIIB: a previously unanswered question.

    Science.gov (United States)

    Thibodeau, Jennifer T; Mishkin, Joseph D; Patel, Parag C; Mammen, Pradeep P A; Markham, David W; Drazner, Mark H

    2012-05-01

    The term New York Heart Association (NYHA) class IIIB has been used increasingly in clinical medicine, including as an inclusion criteria for many clinical trials assessing left ventricular assist devices (LVADs). Indeed, NYHA class IIIB is incorporated in the Food and Drug Administration's approved indication for the Heartmate II. However, on review of the medical literature, we found that there is no consensus definition of NYHA class IIIB. Until the ambiguity is resolved, we suggest that this designation not be used in clinical practice or by investigators leading clinical trials assessing therapies which convey substantial risk to patients and therefore require clarity in describing the enrolled patient population. With ongoing improvements in LVADs, this therapy will increasingly be considered in patients less sick than those who require inotropic support, providing urgency to establish a consensus system of classifying such patients who nevertheless fall within the spectrum of advanced heart failure. Herein we propose a modification of the standard NYHA classification system which can be used to fill this void. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Deslocamento miscível de cátions básicos provenientes da água residuária de mandioca em colunas de solo Miscible displacement of basic cations from cassava processing wastewater in soil columns

    Directory of Open Access Journals (Sweden)

    Ralini F. de Melo

    2006-06-01

    Full Text Available Objetivou-se, com este estudo, determinar os fatores de retardamento e os coeficientes de dispersão-difusão dos íons potássio, sódio, cálcio e magnésio, presentes na água residuária de fecularias ou manipueira, e simular as concentrações residentes em colunas de solos de 160 cm, pelo período de 5 h. Os ensaios foram realizados em laboratório utilizando-se colunas de percolação preenchidas com amostras de Neossolo Quartzarênico órtico espódico (RQo, Latossolo Amarelo distrófico típico (LAd e Latossolo Vermelho Amarelo distrófico típico (LVAd. A concentração dos íons no efluente foram analisados empregando-se a metodologia de deslocamento de fluidos miscíveis. Os valores mais elevados dos fatores de retardamento ocorreram no LVAd, indicando maior retenção dos íons potássio, sódio, cálcio e magnésio nesse solo. Os valores dos coeficientes dispersivos-difusivos decresceram no sentido do RQo para o LVAd, sendo que o maior valor ocorreu no RQo para o íon potássio, e o menor no LVAd, para o íon cálcio. A simulação para um período de aplicação da manipueira de 5 h, mostrou pequeno avanço dos íons na coluna do LVAd, em comparação com RQo e LAd alertando, assim, para os perigos de contaminação de águas subterrâneas ao se aplicar a manipueira nesses solos.This study aimed to determine the retardation factors and the diffusion-dispersion coefficients of the potassium, sodium, calcium and magnesium ions found in the cassava wastewater, as well as to simulate the resident concentrations in soil columns with 160 cm over a five-hours period. The trials were accomplished under laboratory conditions, by using percolation columns fulfilled with materials from the spodic ortic Quartzarenic Neosol (RQo, typical distrophic Yellow Latosol (LAd and typical distrophic Yellow Red Latosol (LVAd. The data of the ion concentrations in effluent were analyzed, by using the miscible fluid displacement methodology. The highest

  12. Costs and reimbursement gaps after implementation of third-generation left ventricular assist devices.

    Science.gov (United States)

    Mishra, Vinod; Geiran, Odd; Fiane, Arnt E; Sørensen, Gro; Andresen, Sølvi; Olsen, Ellen K; Khushi, Ishtiaq; Hagen, Terje P

    2010-01-01

    The purpose of this study was to compare and contrast total hospital costs and subsequent reimbursement of implementing a new program using a third-generation left ventricular assist device (LVAD) in Norway. Between July 2005 and March 2008, the total costs of treatment for 9 patients were examined. Costs were calculated for three periods-the pre-implantation LVAD phase, the LVAD implantation phase and the post-implantation LVAD phase-as well as for total hospital care. Patient-specific costs were obtained prospectively from patient records and included personnel resources, medication, blood products, blood chemistry and microbiology, imaging, and procedure costs including operating room costs. Overhead costs were registered retrospectively and allocated to the specific patient by pre-defined allocation keys. Finally, patient-specific costs and overhead costs were aggregated into total patient costs. The average total patient cost in 2007 U.S. dollars was $735,342 and the median was $613,087 (range $342,581 to $1,256,026). The mean length of stay was 77 days (range 40 to 127 days). For the LVAD implantation phase, the mean cost was $457,795 and median cost was $458,611 (range $246,239 to $677,680). The mean length of stay for the LVAD implantation phase was 55 days (range 25 to 125 days). The diagnosis-related group (DRG) reimbursement (2007) was $143,192. There is significant discrepancy between actual hospital costs and the current Norwegian DRG reimbursement for the LVAD procedure. This discrepancy can be partly explained by excessive costs related to the introduction of a new program with new technology. Costly innovations should be considered in price setting of reimbursement for novel technology. Copyright (c) 2010 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  13. The Role of Implantable Cardioverter Defibrillators in Patients Bridged to Transplantation with a Continuous Flow Left Ventricular Assist Device: A Propensity Score Matched Analysis

    Science.gov (United States)

    Clerkin, Kevin J.; Topkara, Veli K.; Mancini, Donna M.; Yuzefpolskaya, Melana; Demmer, Ryan T.; Dizon, Jose M.; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C.; Garan, A. Reshad

    2016-01-01

    Background Implantable cardioverter defibrillators (ICD) provide a significant mortality benefit for appropriately selected patients with advanced heart failure. ICDs are associated with a mortality benefit when used in patients with a pulsatile left ventricular assist device (LVAD). However it is unclear whether patients with a continuous flow LVAD (CF-LVAD) derive the same benefit. This study sought to determine if the presence of an ICD provided a mortality benefit during CFLVAD support as a bridge to transplantation. Methods Patients were identified in the United Network for Organ Sharing (UNOS) registry that underwent LVAD implantation as bridge to transplantation from May 2004 and April 2014, with follow-up through June 2014. The primary outcome was freedom from death while on CF-LVAD support with adjustment for complications requiring UNOS listing status upgrade. Secondary endpoints included freedom from delisting while on CF-LVAD support and incidence of transplantation. Results 2,990 patients composed the study cohort and propensity score matching identified 1,012 patients with similar propensity scores. There was no difference in survival during device support between patients with and without an ICD (Hazard Ratio [HR] 1.20, 95% Confidence Interval [CI] 0.66-2.17, p=0.55). Adjusting for device complications requiring a UNOS listing status upgrade had minimal influence (HR 1.11, 95% CI 0.60-2.05, p=0.74). There was no increased risk of delisting due to being too sick for those with an ICD (HR 1.08, 95% CI 0.63-1.86, p=0.78). Likewise, the probability of transplantation was similar (HR 1.05, 95% CI 0.87-1.27, p=0.62). Conclusions Among patients bridged to transplantation with a CF-LVAD, the presence of an ICD did not reduce mortality. PMID:28089072

  14. Exploring cognitive bias in destination therapy left ventricular assist device decision making: A retrospective qualitative framework analysis.

    Science.gov (United States)

    Magid, Molly; McIlvennan, Colleen K; Jones, Jaqueline; Nowels, Carolyn T; Allen, Larry A; Thompson, Jocelyn S; Matlock, Dan

    2016-10-01

    Cognitive biases are psychological influences, which cause humans to make decisions, which do not seemingly maximize utility. For people with heart failure, the left ventricular assist device (LVAD) is a surgically implantable device with complex tradeoffs. As such, it represents an excellent model within which to explore cognitive bias in a real-world decision. We conducted a framework analysis to examine for evidence of cognitive bias among people deciding whether or not to get an LVAD. The aim of this study was to explore the influence of cognitive bias on the LVAD decision-making process. We analyzed previously conducted interviews of patients who had either accepted or declined an LVAD using a deductive, predetermined framework of cognitive biases. We coded and analyzed the interviews using an inductive-deductive framework approach, which also allowed for other themes to emerge. We interviewed a total of 22 heart failure patients who had gone through destination therapy LVAD decision making (15 who had accepted the LVAD and 7 who had declined). All patients appeared influenced by state dependence, where both groups described high current state of suffering, but the groups differed in whether they believed LVAD would relieve suffering or not. We found evidence of cognitive bias that appeared to influence decision making in both patient groups, but groups differed in terms of which cognitive biases were present. Among accepters, we found evidence of anchoring bias, availability bias, optimism bias, and affective forecasting. Among decliners, we found evidence of errors in affective forecasting. Medical decision making is often a complicated and multifaceted process that includes cognitive bias as well as other influences. It is important for clinicians to recognize that patients can be affected by cognitive bias, so they can better understand and improve the decision-making process to ensure that patients are fully informed. Published by Elsevier Inc.

  15. Extracorporeal Life Support Bridge to Ventricular Assist Device: The Double Bridge Strategy.

    Science.gov (United States)

    Marasco, Silvana F; Lo, Casey; Murphy, Deirdre; Summerhayes, Robyn; Quayle, Margaret; Zimmet, Adam; Bailey, Michael

    2016-01-01

    In patients requiring left ventricular assist device (LVAD) support, it can be difficult to ascertain suitability for long-term mechanical support with LVAD and eventual transplantation. LVAD implantation in a shocked patient is associated with increased morbidity and mortality. Interest is growing in the utilization of extracorporeal life support (ECLS) as a bridge-to-bridge support for these critically unwell patients. Here, we reviewed our experience with ECLS double bridging. We hypothesized that ECLS double bridging would stabilize end-organ dysfunction and reduce ventricular assist device (VAD) implant perioperative mortality. We conducted a retrospective review of prospectively collected data for 58 consecutive patients implanted with a continuous-flow LVAD between January 2010 and December 2013 at The Alfred Hospital, Melbourne, Victoria, Australia. Twenty-three patients required ECLS support pre-LVAD while 35 patients underwent LVAD implantation without an ECLS bridge. Preoperative morbidity in the ECLS bridge group was reflected by increased postoperative intensive care duration, blood loss, blood product use, and postoperative renal failure, but without negative impact upon survival when compared with the no ECLS group. ECLS stabilization improved end-organ function pre-VAD implant with significant improvements in hepatic and renal dysfunction. This series demonstrates that the use of ECLS bridge to VAD stabilizes end-organ dysfunction and reduces VAD implant perioperative mortality from that traditionally reported in these "crash and burn" patients. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. The NHLBI REVIVE-IT study: Understanding its discontinuation in the context of current left ventricular assist device therapy.

    Science.gov (United States)

    Pagani, Francis D; Aaronson, Keith D; Kormos, Robert; Mann, Douglas L; Spino, Cathie; Jeffries, Neal; Taddei-Peters, Wendy C; Mancini, Donna M; McNamara, Dennis M; Grady, Kathleen L; Gorcsan, John; Petrucci, Ralph; Anderson, Allen S; Glick, Henry A; Acker, Michael A; Eduardo Rame, J; Goldstein, Daniel J; Pamboukian, Salpy V; Miller, Marissa A; Timothy Baldwin, J

    2016-11-01

    The National Institutes of Health National Heart, Lung, and Blood Institute convened a working group in March 2008 to discuss how therapies for heart failure (HF) might be best advanced using clinical trials involving left ventricular assist devices (LVAD). This group opined that the field was ready for a trial to assess the use of long-term ventricular assist device therapy in patients who are less ill than patients currently eligible for destination therapy, which resulted in the Randomized Evaluation of VAD InterVEntion before Inotropic Therapy (REVIVE-IT) pilot study. The specific objective of REVIVE-IT was to compare LVAD therapy with optimal medical management in patients with less advanced HF than current LVAD indications to determine if wider application of permanent LVAD use to less ill patients would be associated with improved survival, quality of life, or functional capacity. REVIVE-IT represented an extraordinary effort to provide data from a randomized clinical trial to inform clinicians, scientists, industry, and regulatory agencies about the efficacy and safety of LVAD therapy in a population with less advanced HF. Despite significant support from the medical community, industry, and governmental agencies, REVIVE-IT failed to accomplish its goal. The reasons for its failure are instructive, and the lessons learned from the REVIVE-IT experience are likely to be relevant to any future study of LVAD therapy in a population with less advanced HF. Copyright © 2016 International Society for Heart and Lung Transplantation. All rights reserved.

  17. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  18. Impact of Vice President Cheney on public interest in left ventricular assist devices and heart transplantation.

    Science.gov (United States)

    Pandey, Ambarish; Abdullah, Kazeen; Drazner, Mark H

    2014-05-01

    Although celebrity illnesses attract a significant amount of media attention in the United States, there are few studies that have looked at how celebrity health conditions impact the awareness of the illness in the general population. Recently, Vice President Cheney underwent left ventricular assist device (LVAD) implantation and subsequently a cardiac transplant. The aim of this study was to determine whether there was evidence of increased interest in these 2 procedures as assessed by social media. We determined the relative frequency of Google searches for LVAD and heart transplantation from 2004 to 2013 using Google trends. We also counted the number of YouTube videos and Twitter messages posted monthly concerning LVADs over a 7-year time frame. There was a significant spike in the Google search interest for LVAD and heart transplantation in the month when Vice President Cheney underwent the respective procedure. Similarly, there was a large increase in YouTube videos and Twitter messages concerning LVADs shortly after he was implanted. In total, these data support the concept that a public figure's illness can significantly influence the public's interest in that condition and its associated therapies. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Peripheral Artery Disease and Continuous Flow Left Ventricle Assist Device: An Engaging Complement Analysis May Help to Guide Treatment.

    Science.gov (United States)

    Falletta, Calogero; Pasta, Salvatore; Raffa, Giuseppe Maria; Crinò, Francesca; Sciacca, Sergio; Clemenza, Francesco

    2018-02-13

    Use of continuous flow left ventricle assist device (CF-LVAD) in advanced heart failure (HF) patients results in clinically relevant improvements in survival, functional capacity, and quality of life. Peripheral artery disease (PAD) can occur in patients with CF-LVAD due to the high rate of concomitance between risk factors for atherosclerosis and HF. Diagnosis of PAD can be difficult in the specific setting of a patient supported by this kind of device because of the marked alteration in waveform morphology and velocity created by the artificial physiology of an LVAD. We report the case of a 53-year-old man with HF secondary to ischemic cardiomyopathy supported by the HeartWare HVAD as bridge to transplant, who after the implant developed symptoms suggestive of PAD. We describe additional computational flow analysis for the study of PAD-related hemodynamic disturbances induced by a CF-LVAD. Flow simulations enhance the information of clinical image data, and may have an application in clinical investigations of the risk of hemodynamic disturbances induced by LVAD implantation. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Novel nonsurgical left ventricular assist device and system.

    Science.gov (United States)

    Misiri, Juna; DeSimone, Christopher V; Park, Soon J; Kushwaha, Sudhir S; Friedman, Paul A; Bruce, Charles J; Asirvatham, Samuel J

    2013-01-01

    Treatment options for advanced stages of congestive heart failure remain limited. Left ventricular assist devices (LVADs) have emerged as a means to support failing circulation. However, these devices are not without significant risk such as major open chest surgery. We utilized a novel approach for device placement at the aorto-left atria continuity as a site to create a conduit capable of accommodating a percutaneous LVAD system. We designed and developed an expandable nitinol based device for placement at this site to create a shunt between the LA and aorta. Our experiments support this anatomic location as an accessible and feasible site for accommodation of an entirely percutaneous LVAD. The novelty of this approach would bypass the left ventricle, and thereby minimize complications and morbidities associated with current LVAD placement. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Theoretical study of heavy metal Cd, Cu, Hg, and Ni(II) adsorption on the kaolinite(0 0 1) surface

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Jian, E-mail: zhaojian0209@aliyun.com [Institute of Applied Physics and Computational Mathematics, PO Box 8009, Beijing 100088 (China); State Key Laboratory of Geomechanics and Deep Underground Engineering, China University of Mining and Technology, Beijing 100083 (China); He, Man-Chao [State Key Laboratory of Geomechanics and Deep Underground Engineering, China University of Mining and Technology, Beijing 100083 (China)

    2014-10-30

    Highlights: • We investigated the adsorption of Cd, Cu, Hg, and Ni(II) on kaolinite(0 0 1) surface. • The adsorption capabilities of the kaolinite for HM atoms were Ni > Cu > Cd > Hg(II). • The adsorption energy increases with the coverage for Cd, Cu, and Hg(II) atoms. • The adsorption energy decreases with the coverage for Ni(II) atoms. - Abstract: Heavy metal pollution is currently of great concern because it has been recognized as a potential threat to air, water, and soil. Adsorption was one of the most popular methods for the removal of heavy metal. The adsorption of heavy metal Cd, Cu, Hg, and Ni(II) atoms on the hydroxylated (0 0 1) surface of kaolinite was investigated using density-functional theory within the generalized gradient approximation and a supercell approach. The coverage dependence of the adsorption structures and energetics were systematically studied for a wide range of coverage Θ [from 0.11 to 1.0 monolayers (ML)] and adsorption sites. The most stable among all possible adsorption sites for Cd(II) atom was the two-fold bridge site followed by the one-fold top site, and the top site was the most favorite adsorption site for Cu and Ni(II) atoms, while the three-fold hollow site was the most stable adsorption site for Hg(II) atom followed by the two-fold bridge site. The adsorption energy increases with the coverage for Cd, Cu, and Hg(II) atoms, thus indicating the higher stability of surface adsorption and a tendency to the formation of adsorbate islands (clusters) with increasing the coverage. However, the adsorption energy of Ni(II) atoms decreases when increasing the coverage. The adsorption capabilities of the kaolinite clay for the heavy metal atoms were in the order of Ni > Cu > Cd > Hg(II). The other properties of the Cd, Cu, Hg, and Ni(II)/kaolinite(0 0 1) system including the different charge distribution, the lattice relaxation, and the electronic density of states were also studied and discussed in detail.

  2. Theoretical study of heavy metal Cd, Cu, Hg, and Ni(II) adsorption on the kaolinite(0 0 1) surface

    International Nuclear Information System (INIS)

    Zhao, Jian; He, Man-Chao

    2014-01-01

    Highlights: • We investigated the adsorption of Cd, Cu, Hg, and Ni(II) on kaolinite(0 0 1) surface. • The adsorption capabilities of the kaolinite for HM atoms were Ni > Cu > Cd > Hg(II). • The adsorption energy increases with the coverage for Cd, Cu, and Hg(II) atoms. • The adsorption energy decreases with the coverage for Ni(II) atoms. - Abstract: Heavy metal pollution is currently of great concern because it has been recognized as a potential threat to air, water, and soil. Adsorption was one of the most popular methods for the removal of heavy metal. The adsorption of heavy metal Cd, Cu, Hg, and Ni(II) atoms on the hydroxylated (0 0 1) surface of kaolinite was investigated using density-functional theory within the generalized gradient approximation and a supercell approach. The coverage dependence of the adsorption structures and energetics were systematically studied for a wide range of coverage Θ [from 0.11 to 1.0 monolayers (ML)] and adsorption sites. The most stable among all possible adsorption sites for Cd(II) atom was the two-fold bridge site followed by the one-fold top site, and the top site was the most favorite adsorption site for Cu and Ni(II) atoms, while the three-fold hollow site was the most stable adsorption site for Hg(II) atom followed by the two-fold bridge site. The adsorption energy increases with the coverage for Cd, Cu, and Hg(II) atoms, thus indicating the higher stability of surface adsorption and a tendency to the formation of adsorbate islands (clusters) with increasing the coverage. However, the adsorption energy of Ni(II) atoms decreases when increasing the coverage. The adsorption capabilities of the kaolinite clay for the heavy metal atoms were in the order of Ni > Cu > Cd > Hg(II). The other properties of the Cd, Cu, Hg, and Ni(II)/kaolinite(0 0 1) system including the different charge distribution, the lattice relaxation, and the electronic density of states were also studied and discussed in detail

  3. Chemistry and the Internal Combustion Engine II: Pollution Problems.

    Science.gov (United States)

    Hunt, C. B.

    1979-01-01

    Discusses pollution problems which arise from the use of internal combustion (IC) engines in the United Kingdom (UK). The IC engine exhaust emissions, controlling IC engine pollution in the UK, and some future developments are also included. (HM)

  4. COST-EFFECTIVENESS OF CONTINUOUS-FLOW LEFT VENTRICULAR ASSIST DEVICES

    NARCIS (Netherlands)

    Neyt, Mattias; Van den Bruel, Ann; Smit, Yolba; De Jonge, Nicolaas; Erasmus, Michiel; Van Dijk, Diederik; Vlayen, Joan

    Objectives: Mechanical circulatory support through left ventricular assist devices (LVADs) improves survival and quality of life for patients with end-stage heart failure who are ineligible for cardiac transplantation. Our aim was to calculate the cost-effectiveness of continuous-flow LVADs.

  5. Clinical Manifestations and Management of Left Ventricular Assist Device–Associated Infections

    OpenAIRE

    Nienaber, Juhsien Jodi C.; Kusne, Shimon; Riaz, Talha; Walker, Randall C.; Baddour, Larry M.; Wright, Alan J.; Park, Soon J.; Vikram, Holenarasipur R.; Keating, Michael R.; Arabia, Francisco A.; Lahr, Brian D.; Sohail, M. Rizwan

    2013-01-01

    We report the clinical manifestations and management of continuous-flow left ventricular assist device (LVAD) infections from a large multicenter cohort. On the basis of these observations, a management algorithm is derived to assist clinical decision making for LVAD infection.

  6. Achalasia symptom response after Heller myotomy segregated by high-resolution manometry subtypes.

    Science.gov (United States)

    Patel, Amit; Patel, Ami; Mirza, Faiz A; Soudagar, Samad; Sayuk, Gregory S; Gyawali, C Prakash

    2016-02-01

    Achalasia is classified into three HRM subtypes that predict outcomes from diverse management strategies. We assessed if symptomatic response varied when a single management strategy-Heller myotomy (HM)-is employed. Treatment-naive subjects with achalasia referred for HM were followed in this observational cohort study. Chicago criteria designated achalasia subtypes (subtype I: no esophageal pressurization; subtype II: panesophageal pressurization in ≥20 % swallows; subtype III: premature contractions in ≥20 % swallows). Symptom questionnaires assessed symptom burden before and after HM on five-point Likert scales (0 = no symptoms, 4 = severe symptoms) and on 10-cm visual analog scales (global symptom severity, GSS); satisfaction with HM was recorded similarly. Data were analyzed to determine predictors of GSS change across subtypes. Sixty achalasia subjects (56.1 ± 2.4 years, 55 % female) fulfilled inclusion criteria, 15 % with subtype I, 58 % with subtype II, and 27 % with subtype III achalasia. Baseline symptoms included dysphagia (solids: 85 %, liquids: 73 %), regurgitation (84 %), and chest pain (35 %); mean GSS was 7.1 ± 0.3. Upon follow-up 2.1 ± 0.2 years after HM, GSS declined to 1.9 ± 0.4 (p < 0.001), with surgical satisfaction score of 8.7 ± 0.3 out of 10; these were similar across achalasia subtypes. On univariate analysis, female gender, Eckardt score, severity of transit symptoms, and maximal IRP predicted linear GSS improvement; female gender (p = 0.003) and dysphagia for liquids (p = 0.043) remained predictive on multivariate analysis. When a uniform surgical approach is utilized, symptomatic outcome and satisfaction with therapy are similar across achalasia subtypes. Female gender and severity of dysphagia for solids may predict better HM outcome.

  7. [Feeding practices with human milk in newborns less than 1.500 g or less than 32 weeks].

    Science.gov (United States)

    Alonso-Díaz, Clara; Utrera-Torres, Isabel; de Alba-Romero, Concepción; Flores-Antón, Beatriz; López-Maestro, María; Lora-Pablos, David; Pallás-Alonso, Carmen R

    2016-07-01

    There is currently no unified policy on either breastfeeding support or enteral nutrition practices, as regards human milk (HM) in pre-term newborns. The aim of this study was to describe breastfeeding support measures, as well as the use of HM in very preterm infants in Spanish public hospitals. A questionnaire on enteral feeding practices was distributed. Data were analysed from units caring for newborns less than 32 weeks or 1,500g. A univariate analysis was performed comparing level ii and iii care units. There was a 91% response rate. A total of 93 units cared for infants less than 32 weeks or 1,500g (17 level ii and 76 level iii), and 49% of the units recorded the breastfeeding rate on discharge. Around 75% (70/93) had a guideline on managing HM (level iii 81 vs. level ii 47%, P=.002), and 25% had access to donor human milk. Just under half (46%) started trophic feeding in the first 6h. Target enteral feeding volume in stable preterm infants was ≥ 180ml/kg/day in 89% of the units (level iii 93% vs. level ii 70%, P =.017). HM fortifier was used in 96% of the units. In 92%, it was added when the required enteral volume was tolerated. In 59% of the units, adjustments in the quantity of fortifier were made according to weight, and in 36%, it depended on analytical criteria. Some units (9%) used pure protein fortifier. There is a marked variability in breastfeeding support measures and in feeding practices of preterm infants in Spanish neonatal units. Copyright © 2015 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  8. Empleo de metodos numericos para el ajuste de los coeficientes de difusividad (D) y convectivo de transferencia de masa (hm) en el secado de alimentos

    OpenAIRE

    Arranz Saiz, Francisco Javier; Correa Hernando, Eva Cristina; Jiménez Ariza, Heidi Tatiana; Diezma Iglesias, Belen; Garcia-Herrero, Javier; Robla Villalba, José Ignacio; Barreiro Elorza, Pilar

    2011-01-01

    Los modelos matemáticos de transferencia de humedad desde el alimento al medio circundante durante el proceso de secado dependen de dos parámetros: coeficiente de difusividad efectiva D y coeficiente convectivo de transferencia de masa hm, cuya determinación experimental se basa en la consideración de un sistema difusivo sencillo de solución analítica bien conocida. Para el caso, que aquí nos ocupa, de difusión monodimensional en una lámina infinita de grosor 2l, la solución analítica de ...

  9. Fuel and fuel pin behaviour in a high burnup fast breeder fuel subassembly: Results of destructive post-irradiation examinations of the KNK II/1 fuel subassembly NY-205

    International Nuclear Information System (INIS)

    Patzer, G.

    1991-05-01

    The report gives a summarizing overview of the design characteristics, of the irradiation history and of the results of the destructive post-irradiation examinations of the fuel pins of the high-burnup fuel subassembly NY-205 of the KNK II first core. This element was operated for about 10 years and reached a maximum local burnup of 175 MWd/kg(HM) and a maximum neutron dose of 67 dpa-NRT. The main design data of this subassembly agree with those of the SNR 300 Mark-Ia, and it reached more than twice of the burnup and a similar neutron dose as foreseen for the SNR 300 fuel subassemblies [de

  10. Psychological distress in patients with a left ventricular assist device and their partners : An exploratory study

    NARCIS (Netherlands)

    Brouwers, C.J.; Denollet, J.; Caliskan, K.; de Jonge, N.; Constantinescu, A.; Young, Q.; Kaan, A.; Pedersen, S.S.

    2015-01-01

    Background: Left ventricular assist device (LVAD) therapy is increasingly used in patients with advanced heart failure,and may have a significant psychological impact on both patients and their partners. Hence, we examined the distress levels of LVAD patients and their partners. Methods: Anxiety,

  11. Psychological distress in patients with a left ventricular assist device and their partners : an exploratory study

    NARCIS (Netherlands)

    Brouwers, Corline; Denollet, Johan; Caliskan, Kadir; de Jonge, N; Constantinescu, Alina; Young, Quincy; Kaan, Annemarie; Pedersen, Susanne S

    BACKGROUND: Left ventricular assist device (LVAD) therapy is increasingly used in patients with advanced heart failure, and may have a significant psychological impact on both patients and their partners. Hence, we examined the distress levels of LVAD patients and their partners. METHODS: Anxiety,

  12. Decision making for destination therapy left ventricular assist devices: "there was no choice" versus "I thought about it an awful lot".

    Science.gov (United States)

    McIlvennan, Colleen K; Allen, Larry A; Nowels, Carolyn; Brieke, Andreas; Cleveland, Joseph C; Matlock, Daniel D

    2014-05-01

    Destination therapy left ventricular assist devices (DT LVADs) are one of the most invasive medical interventions for end-stage illness. How patients decide whether or not to proceed with device implantation is unknown. We aimed to understand the decision-making processes of patients who either accept or decline DT LVADs. Between October 2012 and September 2013, we conducted semistructured, in-depth interviews to understand patients' decision-making experiences. Data were analyzed using a mixed inductive and deductive approach. Twenty-two eligible patients were interviewed, 15 with DT LVADs and 7 who declined. We found a strong dichotomy between decision processes with some patients (11 accepters) being automatic and others (3 accepters, 7 decliners) being reflective in their approach to decision making. The automatic group was characterized by a fear of dying and an over-riding desire to live as long as possible: "[LVAD] was the only option I had…that or push up daisies…so I automatically took this." By contrast, the reflective group went through a reasoned process of weighing risks, benefits, and burdens: "There are worse things than death." Irrespective of approach, most patients experienced the DT LVAD decision as a highly emotional process and many sought support from their families or spiritually. Some patients offered a DT LVAD face the decision by reflecting on a process and reasoning through risks and benefits. For others, the desire to live supersedes such reflective processing. Acknowledging this difference is important when considering how to support patients who are faced with this complex decision. © 2014 American Heart Association, Inc.

  13. De novo aortic insufficiency during long-term support on a left ventricular assist device: a systematic review and meta-analysis.

    Science.gov (United States)

    Deo, Salil V; Sharma, Vikas; Cho, Yang Hyun; Shah, Ishan K; Park, Soon J

    2014-01-01

    Aortic insufficiency (AI) may occur while supported on a left ventricular assist device (LVAD). We conducted a systematic review to determine the incidence, predictors, and consequences of AI during LVAD support. MEDLINE was searched for original studies presenting clinical data regarding patients who developed AI during LVAD implant. Seven observational studies (657 patients) were selected for review; 65% of patients underwent implantation with a continuous-flow device (Cf-LVAD). The incidence of AI was 25% (11-42%) (Support period: 412 ± 281 days). AI increased by 4% (1-6%) per month of support (p < 0.01). AI-positive patients were older at implant (weighted mean difference, 7.7 [4.3; 11.1]; p < 0.01). Female sex (0.002 ± 0.001; p = 0.01) and smaller body surface area (-0.003 ± 0.001 per m; p < 0.01) correlated with progressive AI. Destination therapy patients (odds ratio [OR], 5.3 [1.2, 24]; p = 0.02) and those with Cf-LVAD pumps were likely to develop AI (hazard ratio [HR], 2.2 [1.2, 3.8]; p < 0.01). A closed aortic valve was associated with AI (OR, 4.7 [1.9, 11.8]; p < 0.01). Survival was comparable in both cohorts (HR, 1.5 [0.81, 2.8]; p = 0.2). A significant number of patients develop de novo AI during LVAD support. Advanced age, longer support duration, continuous-flow pumps, and a closed aortic valve are associated with AI. Large cohort studies would improve our understanding of this condition.

  14. Psychological distress in patients with a left ventricular assist device and their partners

    DEFF Research Database (Denmark)

    Brouwers, Corline; Denollet, Johan; Caliskan, Kadir

    2015-01-01

    , depression and post-traumatic stress disorder (PTSD) were assessed at 3-4 weeks after implantation, and at 3 and 6 months follow-up in 33 LVAD patients (73% men; mean age=54±10 years) and 33 partners (27% men; mean age=54±11 years).Results:The prevalence of anxiety in LVAD partners was significantly higher...... between the anxiety, depression and PTSD score of the patient and the depression score of the partner (ranx=0.40, p=0.04; rdep=.40, p=0.04; rPSTD=0.46, p=0.05). Multivariable analyses showed no significant association between the role (patient vs. partner) and anxiety, depression and PTSD over time after...... correction for age, gender and clinical covariates. However, after correction for Type D personality and the use of psychotropic medication the LVAD partners showed significantly higher anxiety (F=6.95, p=0.01) and depression (F=3.94, p=0.04) scores over time compared to LVAD patients...

  15. Decision Making for Destination Therapy Left Ventricular Assist Devices: “There was no choice” versus “I thought about it an awful lot”

    Science.gov (United States)

    McIlvennan, Colleen K.; Allen, Larry A.; Nowels, Carolyn; Brieke, Andreas; Cleveland, Joseph C.; Matlock, Daniel D.

    2014-01-01

    Background Destination therapy left ventricular assist devices (DT LVAD) are one of the most invasive medical interventions for end-stage illness. How patients decide whether or not to proceed with device implantation is unknown. We aimed to understand the decision-making processes of patients who either accept or decline DT LVADs. Methods and Results Between October 2012–September 2013, we conducted semi-structured, in-depth interviews to understand patients’ decision-making experiences. Data were analyzed using a mixed inductive and deductive approach. Twenty-two eligible patients were interviewed, 15 with DT LVADs and 7 who declined. We found a strong dichotomy between decision processes with some patients (11 accepters) being “automatic” and others (3 accepters, 7 decliners) being “reflective” in their approach to decision making. The automatic group was characterized by a fear of dying and an overriding desire to live as long as possible: “[LVAD] was the only option I had…that or push up daisies…so I automatically took this”. In contrast, the reflective group went through a reasoned process of weighing risks, benefits, and burdens: “There are worse things than death.” Irrespective of approach, most patients experienced the DT LVAD decision as a highly emotional process and many sought support from their families or spiritually. Conclusion Some patients offered a DT LVAD face the decision by reflecting on a process and reasoning through risks and benefits. For others, the desire to live supersedes such reflective processing. Acknowledging this difference is important when considering how to support patients who are faced with this complex decision. PMID:24823949

  16. Usefulness of Tricuspid Annular Diameter to Predict Late Right Sided Heart Failure in Patients With Left Ventricular Assist Device.

    Science.gov (United States)

    Nakanishi, Koki; Homma, Shunichi; Han, Jiho; Takayama, Hiroo; Colombo, Paolo C; Yuzefpolskaya, Melana; Garan, Arthur R; Farr, Maryjane A; Kurlansky, Paul; Di Tullio, Marco R; Naka, Yoshifumi; Takeda, Koji

    2018-07-01

    Although late-onset right-sided heart failure is recognized as a clinical problem in the treatment of patients with left ventricular assist devices (LVADs), the mechanism and predictors are unknown. Tricuspid valve (TV) deformation leads to the restriction of the leaflet motion and decreased coaptation, resulting in a functional tricuspid regurgitation that may act as a surrogate marker of late right-sided heart failure. This study aimed to investigate the association of preoperative TV deformation (annulus dilatation and leaflet tethering) with late right-sided heart failure development after continuous-flow LVAD implantation. The study cohort consisted of 274 patients who underwent 2-dimensional echocardiography before LVAD implantation. TV annulus diameter and tethering distance were measured in an apical 4-chamber view. Late right-sided heart failure was defined as right-sided heart failure requiring readmission and medical and/or surgical treatment after initial LVAD implantation. During a mean follow-up of 25.1 ± 19.0 months after LVAD implantation, late right-sided heart failure occurred in 33 patients (12.0%). Multivariate Cox proportional hazard analysis demonstrated that TV annulus diameter (hazard ratio 1.221 per 1 mm, p right-sided heart failure development, whereas leaflet tethering distance was not. The best cut-off value of the TV annular diameter was 41 mm (area under the curve 0.787). Kaplan-Meier analysis showed that patients with dilated TV annulus (TV annular diameter ≥41 mm) exhibited a significantly higher late right-sided heart failure occurrence than those without TV annular enlargement (log-rank p right-sided heart failure after LVAD implantation. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Anemia after continuous-flow left ventricular assist device implantation: characteristics and implications.

    Science.gov (United States)

    Amione-Guerra, Javier; Cruz-Solbes, Ana S; Bhimaraj, Arvind; Trachtenberg, Barry H; Pingali, Sai R; Estep, Jerry D; Park, Myung H; Guha, Ashrith

    2017-09-15

    Anemia is common in patients with heart failure and is associated with adverse outcomes. Management of anemia in CF-LVAD patients is not well studied. Our purpose is to characterize and identify the etiology of anemia in CF-LVAD patients. Secondary objectives are to describe the effect of CF-LVAD on pre-existing anemia and assess its impact after CF-LVAD support. Cross-sectional study from January to July 2015 of ambulatory patients supported with a CF-LVAD for at least 6-months that presented with hemoglobin <12 g/dL and no recent gastrointestinal bleeding. Patients were classified as iron-deficient and non-iron-deficient and compared. Additionally, a retrospective analysis of 116 consecutive patients who underwent CF-LVAD from 2008 to 2013 with reported hemoglobin at 6 months as outpatients were divided into anemic or non-anemic and compared. In our cross-sectional cohort, iron deficiency was the most common cause of anemia. Notably, 49% of the iron-deficient patients were already on iron supplementation. In our retrospective cohort, 59% of the patients were anemic after 6 months of support. Anemic patients were older, had lower albumin, higher brain natriuretic peptide (BNP), worse renal function and New York Heart Association (NYHA) class. Anemia had a HR of 3.16 (95%CI 1.38-7.26) to predict a composite of 1-year death and HF readmissions, as well as HF-readmissions alone. The most common cause of anemia in our study was iron-deficiency; almost half of the patients were iron deficient despite treatment, suggesting that oral iron may not be sufficient to reverse anemia. Anemia regardless of etiology was associated with adverse outcomes.

  18. Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

    Science.gov (United States)

    Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson

    2018-05-10

    The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.

  19. Impact of the Lok-bar for High-precision Radiotherapy with Tomotherapy.

    Science.gov (United States)

    Hirata, Makoto; Monzen, Hajime; Tamura, Mikoto; Kubo, Kazuki; Matsumoto, Kenji; Hanaoka, Kohei; Okumura, Masahiko; Nishimura, Yasumasa

    2018-05-01

    Patient immobilization systems are used to establish a reproducible patient position relative to the couch. In this study, the impact of conventional lok-bars for CT-simulation (CIVCO-bar) and treatment (iBEAM-bar) were compared with a novel lok-bar (mHM-bar) in tomotherapy. Verification was obtained as follows: i. artifacts in CT images; ii. dose attenuation rate of lok-bar, compared to without lok-bar; and iii. dose differences between the calculated and measured absorbed doses. With the CIVCO-bar, there were obvious metal artifacts, while there were nearly no artifacts with the mHM-bar. The mean dose attenuation rates with the mHM-bar and iBEAM-bar were 1.31% and 2.28%, and the mean dose difference was 1.55% and 1.66% for mHM-bar and iBEAM-bar. Using the mHM-bar reduced artifacts on the CT image and improved dose attenuation are obtained. The lok-bar needs to be inserted as a structure set in treatment planning with tomotherapy. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  20. On the thermal conductivity of UO2 nuclear fuel at a high burn-up of around 100 MWd/kgHM

    International Nuclear Information System (INIS)

    Walker, C.T.; Staicu, D.; Sheindlin, M.; Papaioannou, D.; Goll, W.; Sontheimer, F.

    2006-01-01

    A study of the thermal conductivity of a commercial PWR fuel with an average pellet burn-up of 102 MWd/kgHM is described. The thermal conductivity data reported were derived from the thermal diffusivity measured by the laser flash method. The factors determining the fuel thermal conductivity at high burn-up were elucidated by investigating the recovery that occurred during thermal annealing. It was found that the thermal conductivity in the outer region of the fuel was much higher than it would have been if the high burn-up structure were not present. The increase in thermal conductivity is a consequence of the removal of fission products and radiation defects from the fuel lattice during recrystallisation of the fuel grains (an integral part of the formation process of the high burn-up structure). The gas porosity in the high burn-up structure lowers the increase in thermal conductivity caused by recrystallisation

  1. The Effect of Preoperative Cognitive Behavior and Exercise Therapy for a Patient With an Implanted Left Ventricular Assist Device in Korea.

    Science.gov (United States)

    Seo, Yong Gon; Park, Won Hah; Jeon, Eun Seok; Sung, Ji Dong; Jang, Mi Ja

    2017-10-01

    Left ventricular assist devices (LVADs) are used in patients with progressive heart failure symptoms to provide circulatory support. Patients with LVADs are referred to inpatient cardiac rehabilitation to prevent postoperative complications and improve aerobic capacity and quality of life. Preoperative exercise therapy for cardiac patients is an emerging treatment modality, and several studies have reported that it improves postoperative outcomes, such as length of hospital stay and postoperative complications. This case report describes the benefits of preoperative cognitive behavioral and exercise therapy in a Korean patient undergoing LVAD implantation. V. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  2. When withdrawal of life-sustaining care does more than allow death to take its course: the dilemma of left ventricular assist devices.

    Science.gov (United States)

    Bramstedt, K A; Wenger, N S

    2001-05-01

    Left ventricular assist devices (LVADs) are a relatively new technology that is increasingly used to preserve cardiac function. These devices work by a mechanism that may complicate ethical decision-making for patients who subsequently lose decision-making capacity and are no longer considered transplant candidates. Using a clinical case from our medical center, we explored the complex ethical issues associated with the discontinuation of LVAD therapy by discussing how this device is distinct from the withdrawal of other treatments. While halting an implanted LVAD may permit a patient to die, the deactivated device itself may contribute to patient death due to the potential for blood backflow and pooling, as well as the disruption of heart contractility. Inadequate informed consent and failure to appoint a surrogate decision-maker in advance of the implant procedure resulted in a complex ethical dilemma for the patient's family and the medical team. Clinicians and families must consider the benefits and burdens of LVAD therapy as they do when considering removal of other life-sustaining treatment. The informed consent process associated with LVADs as bridging technology should include extensive consideration of the purpose of the device, future circumstances in which it may be halted, and how such situations would be recognized and handled. Appointment of a surrogate decision-maker before the surgical procedure is essential.

  3. Wave Intensity Analysis of Right Ventricular Function during Pulsed Operation of Rotary Left Ventricular Assist Devices.

    Science.gov (United States)

    Bouwmeester, J Christopher; Park, Jiheum; Valdovinos, John; Bonde, Pramod

    2018-05-29

    Changing the speed of left ventricular assist devices (LVADs) cyclically may be useful to restore aortic pulsatility; however, the effects of this pulsation on right ventricular (RV) function are unknown. This study investigates the effects of direct ventricular interaction by quantifying the amount of wave energy created by RV contraction when axial and centrifugal LVADs are used to assist the left ventricle. In 4 anesthetized pigs, pressure and flow were measured in the main pulmonary artery and wave intensity analysis was used to identify and quantify the energy of waves created by the RV. The axial pump depressed the intensity of waves created by RV contraction compared with the centrifugal pump. In both pump designs, there were only minor and variable differences between the continuous and pulsed operation on RV function. The axial pump causes the RV to contract with less energy compared with a centrifugal design. Diminishing the ability of the RV to produce less energy translates to less pressure and flow produced, which may lead to LVAD-induced RV failure. The effects of pulsed LVAD operation on the RV appear to be minimal during acute observation of healthy hearts. Further study is necessary to uncover the effects of other modes of speed modulation with healthy and unhealthy hearts to determine if pulsed operation will benefit patients by reducing LVAD complications.

  4. In Silico Modeling and Functional Interpretations of Cry1Ab15 Toxin from Bacillus thuringiensis BtB-Hm-16

    Directory of Open Access Journals (Sweden)

    Sudhanshu Kashyap

    2013-01-01

    Full Text Available The theoretical homology based structural model of Cry1Ab15 δ-endotoxin produced by Bacillus thuringiensis BtB-Hm-16 was predicted using the Cry1Aa template (resolution 2.25 Å. The Cry1Ab15 resembles the template structure by sharing a common three-domain extending conformation structure responsible for pore-forming and specificity determination. The novel structural differences found are the presence of β0 and α3, and the absence of α7b, β1a, α10a, α10b, β12, and α11a while α9 is located spatially downstream. Validation by SUPERPOSE and with the use of PROCHECK program showed folding of 98% of modeled residues in a favourable and stable orientation with a total energy Z-score of −6.56; the constructed model has an RMSD of only 1.15 Å. These increments of 3D structure information will be helpful in the design of domain swapping experiments aimed at improving toxicity and will help in elucidating the common mechanism of toxin action.

  5. Study of diffuse H II regions potentially forming part of the gas streams around Sgr A*

    Science.gov (United States)

    Armijos-Abendaño, J.; López, E.; Martín-Pintado, J.; Báez-Rubio, A.; Aravena, M.; Requena-Torres, M. A.; Martín, S.; Llerena, M.; Aldás, F.; Logan, C.; Rodríguez-Franco, A.

    2018-05-01

    We present a study of diffuse extended ionized gas towards three clouds located in the Galactic Centre (GC). One line of sight (LOS) is towards the 20 km s-1 cloud (LOS-0.11) in the Sgr A region, another LOS is towards the 50 km s-1 cloud (LOS-0.02), also in Sgr A, while the third is towards the Sgr B2 cloud (LOS+0.693). The emission from the ionized gas is detected from Hnα and Hmβ radio recombination lines (RRLs). Henα and Hemβ RRL emission is detected with the same n and m as those from the hydrogen RRLs only towards LOS+0.693. RRLs probe gas with positive and negative velocities towards the two Sgr A sources. The Hmβ to Hnα ratios reveal that the ionized gas is emitted under local thermodynamic equilibrium conditions in these regions. We find a He to H mass fraction of 0.29±0.01 consistent with the typical GC value, supporting the idea that massive stars have increased the He abundance compared to its primordial value. Physical properties are derived for the studied sources. We propose that the negative velocity component of both Sgr A sources is part of gas streams considered previously to model the GC cloud kinematics. Associated massive stars with what are presumably the closest H II regions to LOS-0.11 (positive velocity gas), LOS-0.02, and LOS+0.693 could be the main sources of ultraviolet photons ionizing the gas. The negative velocity components of both Sgr A sources might be ionized by the same massive stars, but only if they are in the same gas stream.

  6. Deep RNA sequencing reveals dynamic regulation of myocardial noncoding RNAs in failing human heart and remodeling with mechanical circulatory support.

    Science.gov (United States)

    Yang, Kai-Chien; Yamada, Kathryn A; Patel, Akshar Y; Topkara, Veli K; George, Isaac; Cheema, Faisal H; Ewald, Gregory A; Mann, Douglas L; Nerbonne, Jeanne M

    2014-03-04

    Microarrays have been used extensively to profile transcriptome remodeling in failing human heart, although the genomic coverage provided is limited and fails to provide a detailed picture of the myocardial transcriptome landscape. Here, we describe sequencing-based transcriptome profiling, providing comprehensive analysis of myocardial mRNA, microRNA (miRNA), and long noncoding RNA (lncRNA) expression in failing human heart before and after mechanical support with a left ventricular (LV) assist device (LVAD). Deep sequencing of RNA isolated from paired nonischemic (NICM; n=8) and ischemic (ICM; n=8) human failing LV samples collected before and after LVAD and from nonfailing human LV (n=8) was conducted. These analyses revealed high abundance of mRNA (37%) and lncRNA (71%) of mitochondrial origin. miRNASeq revealed 160 and 147 differentially expressed miRNAs in ICM and NICM, respectively, compared with nonfailing LV. Among these, only 2 (ICM) and 5 (NICM) miRNAs are normalized with LVAD. RNASeq detected 18 480, including 113 novel, lncRNAs in human LV. Among the 679 (ICM) and 570 (NICM) lncRNAs differentially expressed with heart failure, ≈10% are improved or normalized with LVAD. In addition, the expression signature of lncRNAs, but not miRNAs or mRNAs, distinguishes ICM from NICM. Further analysis suggests that cis-gene regulation represents a major mechanism of action of human cardiac lncRNAs. The myocardial transcriptome is dynamically regulated in advanced heart failure and after LVAD support. The expression profiles of lncRNAs, but not mRNAs or miRNAs, can discriminate failing hearts of different pathologies and are markedly altered in response to LVAD support. These results suggest an important role for lncRNAs in the pathogenesis of heart failure and in reverse remodeling observed with mechanical support.

  7. Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Programming in Patients With a Left Ventricular Assist Device.

    Science.gov (United States)

    Richardson, Travis D; Hale, Leslie; Arteaga, Christopher; Xu, Meng; Keebler, Mary; Schlendorf, Kelly; Danter, Matthew; Shah, Ashish; Lindenfeld, JoAnn; Ellis, Christopher R

    2018-02-23

    Ventricular arrhythmias are common in patients with left ventricular assist devices (LVADs) but are often hemodynamically tolerated. Optimal implantable cardioverter defibrillator (ICD) tachy-programming strategies in patients with LVAD have not been determined. We sought to determine if an ultra-conservative ICD programming strategy in patients with LVAD affects ICD shocks. Adult patients with an existing ICD undergoing continuous flow LVAD implantation were randomized to standard ICD programming by their treating physician or an ultra-conservative ICD programming strategy utilizing maximal allowable intervals to detection in the ventricular fibrillation and ventricular tachycardia zones with use of ATP. Patients with cardiac resynchronization therapy (CRT) devices were also randomized to CRT ON or OFF. Patients were followed a minimum of 6 months. The primary outcome was time to first ICD shock. Among the 83 patients studied, we found no statistically significant difference in time to first ICD shock or total ICD shocks between groups. In the ultra-conservative group 16% of patients experienced at least one shock compared with 21% in the control group ( P =0.66). There was no difference in mortality, arrhythmic hospitalization, or hospitalization for heart failure. In the 41 patients with CRT ICDs fewer shocks were observed with CRT-ON but this was not statistically significant: 10% of patients with CRT-ON (n=21) versus 38% with CRT-OFF (n=20) received shocks ( P =0.08). An ultra-conservative programming strategy did not reduce ICD shocks. Programming restrictions on ventricular tachycardia and ventricular fibrillation zone therapy should be reconsidered for the LVAD population. The role of CRT in patients with LVAD warrants further investigation. URL: https://www.clinicaltrials.gov. Unique identifier: NCT01977703. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  8. Complexation humic substances of soils with metal ions as the main way migration of matals from soil to water

    Science.gov (United States)

    Dinu, Marina

    2013-04-01

    northern taiga soils; (2) similar amounts of oxygen bearing fragments, hydrocarbon constituents, and nitrogen bearing components in the mixed forest zones; (3) occurrence of aromatic and aliphatic hydrocarbons in HM of steppe soils. The HM functional characteristics influence substantially the stability constants of complexes with metal ions and complex stoichiometry: Fe(III)>Cu(II)>Pb(II)>Al(III)>Co(II)>Ni(II)>Cd(II)>Zn(II)>Cr(III)>Mg(II)>Sr(II)>Ca(II)>Mn(II) - northern taiga soils; Cu(II)>Fe(III)>Al(III)>Ni(II)>Zn(II)>Pb(II)>Co(II)>Cd(II)>Sr(II)>Mn(II)>Cr(III)>Ca(II)>Mg(II) - mixed forest zones; Fe(III)>Cu(II)>Al(III)>Pb(II)>Ni(II)>Zn(II)>Co(II)>Ca(II)>Cd(II)>Sr(II)>Mg(II)>Cr(III)>Mn(II) - steppe soils. 1. T.I. Moiseenko, L.P. Kudryavtseva, and N.A. Gashkina, Scattered Element in Surface Land Waters: Technophility, Bioaccumulation, and Ecotoxicology (Nauka, Moscow, 2006) 2. G. M. Varshal, Ext. Abstr. Doct. Dis. Chem. (Inst. Geokh. Analit. Khim. RAN, Moscow, 1994).. 4. D.S. Orlov, Humic Acids (MGU, Moscow, 1986) 5. D.V. Kovalevsky, Ext. Abstr. Cand. Dis. Chem. (MGU, Moscow, 1998). 6. I.A. Linnik and B. I. Nabivanets, Metal Migration Forms in Surface Fresh Waters (Gidrometizdat, Leningrad, 1985) 7. Hartley, F., Burgess, C., and Alcoc, R., Solution Equilibria (Ellis Horwood, Chichester (UK), 1980). 8. Yu. Yu. Lur'e, Reference Book of Physicochemical Values (Nauka, Moscow, 2000)

  9. Successful Implantation of a Left Ventricular Assist Device After Treatment With the Paracor HeartNet.

    Science.gov (United States)

    Schweiger, Martin; Stepanenko, Alexander; Potapov, Evgenji; Drews, Thorsten; Hetzer, Roland; Krabatsch, Thomas

    2010-01-01

    The Paracor HeartNet, a ventricular constraint device for the treatment of heart failure (HF), is implanted through a left lateral thoracotomy. It envelopes the heart like a mesh "bag." This method of application raises the question of whether adhesions with the pericardium allow the safe implantation of a left ventricular assist device (LVAD) if HF worsens. A male patient who had undergone implantation of the Paracor HeartNet 42 months earlier presented with advanced HF for cardiac transplantation. The patient's condition deteriorated, and because no suitable organ for transplantation was available, implantation of an LVAD became necessary. Surgery was performed via a median sternotomy without complications. No severe adhesions were found. This is the first report on "how to do" LVAD implantation after Paracor HeartNet implantation with images and information about cutting the constraint. Because the Paracor HeartNet is "wrapped" around the heart, concerns persist that severe adhesions with the pericardium might occur. In this case, LVAD implantation after therapy with the Paracor HeartNet was without complications, and the expected massive adhesions were absent.

  10. The total artificial heart.

    Science.gov (United States)

    Cook, Jason A; Shah, Keyur B; Quader, Mohammed A; Cooke, Richard H; Kasirajan, Vigneshwar; Rao, Kris K; Smallfield, Melissa C; Tchoukina, Inna; Tang, Daniel G

    2015-12-01

    The total artificial heart (TAH) is a form of mechanical circulatory support in which the patient's native ventricles and valves are explanted and replaced by a pneumatically powered artificial heart. Currently, the TAH is approved for use in end-stage biventricular heart failure as a bridge to heart transplantation. However, with an increasing global burden of cardiovascular disease and congestive heart failure, the number of patients with end-stage heart failure awaiting heart transplantation now far exceeds the number of available hearts. As a result, the use of mechanical circulatory support, including the TAH and left ventricular assist device (LVAD), is growing exponentially. The LVAD is already widely used as destination therapy, and destination therapy for the TAH is under investigation. While most patients requiring mechanical circulatory support are effectively treated with LVADs, there is a subset of patients with concurrent right ventricular failure or major structural barriers to LVAD placement in whom TAH may be more appropriate. The history, indications, surgical implantation, post device management, outcomes, complications, and future direction of the TAH are discussed in this review.

  11. Quantitative measurement of regional cerebral blood flow using 99mTc-HM-PAO SPECT

    International Nuclear Information System (INIS)

    Tanaka, Hisashi; Nakamura, Yusaku; Yagi, Yuji; Miura, Kosuke; Takahashi, Mitsuo

    1994-01-01

    This study examined a simple method for measuring the regional cerebral blood flow (rCBF) using 99m Tc-HM-PAO SPECT. The mean CBF (mCBF) was determined by the Patlack plot method and rCBF was calculated with Lassen's correction algorithm, as reported by Matsuda et al. The cerebral hemisphere was employed as the reference region for Lassen's correction. The reference RI count rate was calculated from the left cerebral hemisphere at the basal ganglia level and the correction factor α was fixed at 2.0. As a result, rCBF could be measured more easily than by Matsuda's method. The contribution of age, laterality and gender to the CBF of normal subjects were studied. The mCBF value of 26 normal subjects was 53.8±6.4 ml/100 g/min and showed a significant correlation with advancing age (R=0.644, p=0.0004, n=26). The mean values for rCBF of the cerebellum, frontal area, temporal area, occipital area and parietal area were 77.3±6.6 ml/100 g/min, 70.2±9.1 ml/100 g/min, 72.3±7.5 ml/100 g/min, 71.8±6.2 ml/100 g/min and 73.8±8.6 ml/100 g/min, respectively. There were no gender or laterality differences in the mCBF or respective rCBF values. Each of the above listed regions, except for the occipital area, demonstrated a significant correlation with advancing age. The most remarkable decrease in rCBF with age was noted in the frontal area (R=0.757, p=0.001, n=26). (author)

  12. Exercise therapy for an older patient with left ventricular assist device.

    Science.gov (United States)

    Park, Won Hah; Seo, Yong Gon; Sung, Ji Dong

    2014-06-01

    A left ventricular assist device (LVAD) is a mechanical circulation support implanted for patients with end-stage heart failure. It may be used either as a bridge to cardiac transplantation or as a destination therapy. The health of a 75-year-old man with a medical history of systolic heart failure worsened. Therefore, he was recommended to have implanted a LVAD (Thoratec Corp.) as a destination therapy. After the surgery, he was enrolled in patient cardiac rehabilitation for the improvement of dyspnea and exercise capacity. In results, there is an improvement on his exercise capacity and quality of life. For the first time in Korea, we reported a benefit of exercise therapy after being implanted with a LVAD.

  13. Ventricular fibrillation in an ambulatory patient supported by a left ventricular assist device: highlighting the ICD controversy.

    Science.gov (United States)

    Boilson, Barry A; Durham, Lucian A; Park, Soon J

    2012-01-01

    Left ventricular assist devices (LVADs) provide an effective means of managing advanced pump failure as a means of bridging to cardiac transplantation or as permanent therapy. Although ventricular arrhythmias remain common post-LVAD implantation, such therapy may allow malignant arrhythmias to be tolerated hemodynamically. This report describes the clinical findings in a patient who had likely been in a ventricular tachyarrhythmia for several days and presented in ventricular fibrillation, ambulatory, and mentating normally. This report, with previous similar reports, is additive to the body of evidence that LVADs alter the physiologic impact of ventricular arrhythmias in advanced heart failure and highlights the need for thoughtful programming of implantable cardioverter defibrillator therapies in these patients.

  14. Taking a back seat

    DEFF Research Database (Denmark)

    Egerod, Ingrid; Overgaard, Dorthe

    2012-01-01

    As more patients with cardiac failure are being bridged to transplantation with left ventricular assist devices (LVAD), more insight into the lives of their close relatives is needed.......As more patients with cardiac failure are being bridged to transplantation with left ventricular assist devices (LVAD), more insight into the lives of their close relatives is needed....

  15. Cardiac transplantation after bridged therapy with continuous flow left ventricular assist devices.

    Science.gov (United States)

    Deo, Salil V; Sung, Kiick; Daly, Richard C; Shah, Ishan K; Altarabsheh, Salah E; Stulak, John M; Joyce, Lyle D; Boilson, Barry A; Kushwaha, Sudhir S; Park, Soon J

    2014-03-01

    Cardiac transplantation is an effective surgical therapy for end-stage heart failure. Patients (pts) may need to be bridged with a continuous flow left ventricular assist device (CF-LVAD) while on the transplant list as logistic factors like organ availability are unknown. Cardiac transplantation post-LVAD can be a surgically challenging procedure and outcome in these pts is perceived to be poorer based on experience with earlier generation pulsatile flow pumps. Data from a single institution comparing these pts with those undergoing direct transplantation in the present era of continuous flow device therapy are limited. Evaluate results of cardiac transplantation in pts bridged with a CF-LVAD (BTx) and compare outcomes with pts undergoing direct transplantation (Tx) in a single institution. From June 2007 till January 2012, 106 pts underwent cardiac transplantation. Among these, 37 (35%) pts (51±11 years; 85% male) were bridged with a CF-LVAD (BTx), while 70 (65%) comprised the Tx group (53±12 years; 72% males). The median duration of LVAD support was 227 (153,327) days. During the period of LVAD support, 10/37 (27%) pts were upgraded to status 1A and all were successfully transplanted. Median hospital stay in the BTx (14 days) was slightly longer than the Tx group (12 days) but not statistically significant (p=0.21). In-hospital mortality in the BTx (5%) and Tx (1%) were comparable (p=0.25). Estimated late survival in the BTx cohort was 94±7, 90±10 and 83±16% at the end of one, two and three years, respectively which was comparable to 97±4%, 93±6% and 89±9% for the Tx group (p=0.50). Cardiac transplantation after LVAD implant can be performed with excellent results. Patients can be supported on the left ventricular assist device even for periods close to a year with good outcome after cardiac transplantation. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand

  16. MAGIICAT III. Interpreting self-similarity of the circumgalactic medium with virial mass using Mg II absorption

    Energy Technology Data Exchange (ETDEWEB)

    Churchill, Christopher W.; Trujillo-Gomez, Sebastian; Nielsen, Nikole M. [New Mexico State University, Las Cruces, NM 88003 (United States); Kacprzak, Glenn G. [Swinburne University of Technology, Victoria 3122 (Australia)

    2013-12-10

    In Churchill et al., we used halo abundance matching applied to 182 galaxies in the Mg II Absorber-Galaxy Catalog (MAGIICAT) and showed that the mean Mg II λ2796 equivalent width follows a tight inverse-square power law, W{sub r} (2796)∝(D/R {sub vir}){sup –2}, with projected location relative to the galaxy virial radius and that the Mg II absorption covering fraction is effectively invariant with galaxy virial mass, M {sub h}, over the range 10.7 ≤ log M {sub h}/M {sub ☉} ≤ 13.9. In this work, we explore multivariate relationships between W{sub r} (2796), virial mass, impact parameter, virial radius, and the theoretical cooling radius that further elucidate self-similarity in the cool/warm (T = 10{sup 4}-10{sup 4.5} K) circumgalactic medium (CGM) with virial mass. We show that virial mass determines the extent and strength of the Mg II absorbing gas such that the mean W{sub r} (2796) increases with virial mass at fixed distance while decreasing with galactocentric distance for fixed virial mass. The majority of the absorbing gas resides within D ≅ 0.3 R {sub vir}, independent of both virial mass and minimum absorption threshold; inside this region, and perhaps also in the region 0.3 < D/R {sub vir} ≤ 1, the mean W{sub r} (2796) is independent of virial mass. Contrary to absorber-galaxy cross-correlation studies, we show there is no anti-correlation between W{sub r} (2796) and virial mass. We discuss how simulations and theory constrained by observations support self-similarity of the cool/warm CGM via the physics governing star formation, gas-phase metal enrichment, recycling efficiency of galactic scale winds, filament and merger accretion, and overdensity of local environment as a function of virial mass.

  17. Exercise Capacity and Functional Performance in Heart Failure Patients Supported by a Left Ventricular Assist Device at Discharge From Inpatient Rehabilitation.

    Science.gov (United States)

    Schmidt, Thomas; Bjarnason-Wehrens, Birna; Bartsch, Petra; Deniz, Ezin; Schmitto, Jan; Schulte-Eistrup, Sebastian; Willemsen, Detlev; Reiss, Nils

    2018-01-01

    Adequate physical and functional performance is an important prerequisite for renewed participation and integration in self-determined private and (where appropriate) professional lives following left ventricular assist device (LVAD) implantation. During cardiac rehabilitation (CR), individually adapted exercise programs aim to increase exercise capacity and functional performance. A retrospective analysis of cardiopulmonary exercise capacity and functional performance in LVAD patients at discharge from a cardiac rehabilitation program was conducted. The results from 68 LVAD patients (59 males, 9 females; 55.9 ± 11.7 years; 47 HVAD, 2 MVAD, 15 HeartMate II, 4 HeartMate 3, and 4 different implanting centers) were included in the analysis. Exercise capacity was assessed using a cardiopulmonary exercise test on a bicycle ergometer (ramp protocol; 10 W/min). The 6-min walk test was used to determine functional performance. At discharge from CR (53 ± 17 days after implantation), the mean peak work load achieved was 62.2 ± 19.3 W (38% of predicted values) or 0.79 ± 0.25 W/kg body weight. The mean cardiopulmonary exercise capacity (relative peak oxygen uptake) was 10.6 ± 5.3 mL/kg/min (37% of predicted values). The 6-min walk distance improved significantly during CR (325 ± 106 to 405 ± 77 m; P exercise capacity remains considerably restricted. In contrast, functional performance, measured by the 6-min walk distance, reaches an acceptable level. Light everyday tasks seem to be realistically surmountable for patients, making discharge from inpatient rehabilitation possible. Long-term monitoring is required in order to evaluate the situation and how it develops further. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Persistent blood stream infection in patients supported with a continuous-flow left ventricular assist device is associated with an increased risk of cerebrovascular accidents.

    Science.gov (United States)

    Trachtenberg, Barry H; Cordero-Reyes, Andrea M; Aldeiri, Molham; Alvarez, Paulino; Bhimaraj, Arvind; Ashrith, Guha; Elias, Barbara; Suarez, Erik E; Bruckner, Brian; Loebe, Matthias; Harris, Richard L; Zhang, J Yi; Torre-Amione, Guillermo; Estep, Jerry D

    2015-02-01

    Common adverse events in patients supported with Continuous-flow left ventricular assist devices (CF-LVAD) include infections and cerebrovascular accidents (CVA). Some studies have suggested a possible association between blood stream infection (BSI) and CVA. Medical records of patients who received Heartmate II (HMII) CF-LVADs in 2008-2012 at a single center were reviewed. CVA was categorized as either hemorrhagic (HCVA) or ischemic (ICVA). BSI was divided into persistent (pBSI) and nonpersistent (non-pBSI). pBSI was defined as BSI with the same organism on repeated blood culture >72 hours from initial blood culture despite antibiotics. Univariate and multivariate analyses were performed to determine predictors. A total of 149 patients had HMII implanted; 76% were male, and the overall mean age was 55.4 ± 13 years. There were a total of 19 (13%) patients who had CVA (7 HCVA and 12 ICVA) at a median of 295 days (range 5-1,096 days) after implantation. There were a total of 28 (19%) patients with pBSI and 17 (11%) patients with non-pBSI. Patients with pBSI had a trend toward greater BMI (31 kg/m(2) vs 27 kg/m(2); P = .09), and longer duration of support (1,019 d vs 371 d; P < .001) compared with those with non-pBSI. Persistent BSI was associated with an increased risk of mortality and with all-cause CVA on multivariate analysis (odds ratio [OR] 5.97; P = .003) as well as persistent Pseudomonas aeruginosa infection (OR 4.54; P = .048). Persistent BSI is not uncommon in patients supported by CF-LVAD and is highly associated with all-cause CVA and increased all-cause mortality. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Risk factors, mortality, and timing of ischemic and hemorrhagic stroke with left ventricular assist devices.

    Science.gov (United States)

    Frontera, Jennifer A; Starling, Randall; Cho, Sung-Min; Nowacki, Amy S; Uchino, Ken; Hussain, M Shazam; Mountis, Maria; Moazami, Nader

    2017-06-01

    Stroke is a major cause of mortality after left ventricular assist device (LVAD) placement. Prospectively collected data of patients with HeartMate II (n = 332) and HeartWare (n = 70) LVADs from October 21, 2004, to May 19, 2015, were reviewed. Predictors of early (during index hospitalization) and late (post-discharge) ischemic and hemorrhagic stroke and association of stroke subtypes with mortality were assessed. Of 402 patients, 83 strokes occurred in 69 patients (17%; 0.14 events per patient-year [EPPY]): early ischemic stroke in 18/402 (4%; 0.03 EPPY), early hemorrhagic stroke in 11/402 (3%; 0.02 EPPY), late ischemic stroke in 25/402 (6%; 0.04 EPPY) and late hemorrhagic stroke in 29/402 (7%; 0.05 EPPY). Risk of stroke and death among patients with stroke was bimodal with highest risks immediately post-implant and increasing again 9-12 months later. Risk of death declined over time in patients without stroke. Modifiable stroke risk factors varied according to timing and stroke type, including tobacco use, bacteremia, pump thrombosis, pump infection, and hypertension (all p hemorrhagic stroke (adjusted odds ratio [aOR] 4.3, 95% confidence interval [CI] 1.0-17.8, p = 0.04), late ischemic stroke (aOR 3.2, 95% CI 1.1-9.0, p = 0.03), and late hemorrhagic stroke (aOR 3.7, 95% CI 1.5-9.2, p = 0.005) predicted death, whereas early ischemic stroke did not. Stroke is a leading cause and predictor of death in patients with LVADs. Risk of stroke and death among patients with stroke is bimodal, with highest risk at time of implant and increasing risk again after 9-12 months. Management of modifiable risk factors may reduce stroke and mortality rates. Copyright © 2017 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  20. An exploratory study of sleep quality, daytime function, and quality of life in patients with mechanical circulatory support.

    Science.gov (United States)

    Casida, Jesus M; Brewer, Robert J; Smith, Cheryl; Davis, Jean E

    2012-07-01

    To identify and describe: (1) characteristics of sleep quality, daytime sleepiness, and quality of life (QOL) pre and post implantation of a left ventricular assist device (LVAD); (2) changes in sleep quality, daytime sleepiness, and QOL at baseline and 6 months post implant; and (3) relationships among the sleep quality, daytime sleepiness, and QOL variables. We employed an exploratory research design. Fifteen patients with continuous/non-pulsatile flow LVAD consented to partake in the study. However, only 12 patients completed the baseline and 6-month post-LVAD implant data. We used the Pittsburgh Sleep Quality Index (PSQI), Epworth Sleepiness Scale (ESS), and Minnesota Living with Heart Failure Questionnaire (MLHFQ) to measure study variables. Data were analyzed using IBM SPSS 19.0 software. Patients reported worse sleep quality accompanied by daytime sleepiness particularly at baseline, and persisting up to 6 months post LVAD implant. A significant improvement in QOL was observed at 6 months post implant, but remained at poor levels. Correlations among sleep disturbance and daytime dysfunction components of PSQI and global daytime sleepiness (ESS) with QOL were strong (Pearson's correlations r >.60; p values sleep quality, daytime sleepiness, and QOL in patients with LVADs. Our findings offer beginning evidence about the sleep-QOL connection in this population which warrants attention in clinical practice and research. Further research is required to clearly elucidate these phenomena in patients with mechanical circulatory support and other implantable artificial organs.

  1. Great day: H.M. Queen Elizabeth II at the Calder Hall opening

    International Nuclear Information System (INIS)

    1956-01-01

    The opening of the world's first nuclear power station, Calder Hall, was a major event in the history of post-war Britain. This film describes the construction and design of the station and its opening by the Queen. It is also an interesting historical document reflecting the beliefs and aspirations of the time. (author)

  2. Functional regional cerebral blood flow SPECT using 99mTc-HM-PAO by speech memory tasks

    International Nuclear Information System (INIS)

    Tohyama, Junko

    1993-01-01

    Using single photon emission computed tomography (SPECT) with Tc-99m HA-PAO, changes in regional cerebral blood flow (rCBF) by giving word memory and Miyake's tasks were determined for localizatin of speech memory function. Twice injection method of Tc-99m HM-PAO was used to obtain subtraction SPECT images; and positioning of the 1st and 2nd SPECT was determined by phantom study. To prevent artifacts and changes in rCBF as far as possible, the subjects were informed word fluency and Miyake's tasks sufficiently. When giving word fluency approach, an increase in rCBF was observed in both the operculum and the supratemporal convolution of dominant hemisphere. When giving Miyake's approach, it was observed predominantly in the supratemporal convolution of dominant hemisphere. Although it was also observed in the base of frontal lobe and operculum, there was no bilateral difference. An increased rCBF in the basal nucleus was more clearly observed by Miyake's than word fluency tasks without bilateral differences. There was no definitive increase in rCBF in the Papez's circuit responsible for memory and emotion by either word fluency or Miyake's tasks. In mentally mild disorder patients, an increased rCBF was observed in the same areas as those in normal subjects. In such patients having a decreased rCBF at rest, an increased rCBF was seen in the contralateral hemisphere and the surrounding areas of the lesions, suggesting compensatory mechanism. (N.K.) 65 refs

  3. Left Ventricular Assist Device Implantation with Concomitant Aortic Valve and Ascending Aortic Replacement.

    Science.gov (United States)

    Huenges, Katharina; Panholzer, Bernd; Cremer, Jochen; Haneya, Assad

    2018-01-01

    Left ventricular assist device (LVAD) is nowadays a routine therapy for patients with advanced heart failure. We present the case of a 74-year-old male patient who was admitted to our center with terminal heart failure in dilated cardiomyopathy and ascending aortic aneurysm with aortic valve regurgitation. The LVAD implantation with simultaneous aortic valve and supracoronary ascending aortic replacement was successfully performed.

  4. Media Fill Test for validation of autologous leukocytes separation and labelling by (99m)Tc-HmPAO.

    Science.gov (United States)

    Urbano, Nicoletta; Modoni, Sergio; Schillaci, Orazio

    2013-01-01

    Manufacturing of sterile products must be carried out in order to minimize risks of microbiological contamination. White blood cells (WBC) labelled with (99m)Tc-exametazime ((99m)Tc-hexamethylpropyleneamine oxime; (99m)Tc-HMPAO) are being successfully applied in the field of infection/inflammation scintigraphy for many years. In our radiopharmacy lab, separation and labelling of autologous leukocytes with (99m)Tc-HMPAO were performed in a laminar flow cabinet not classified and placed in a controlled area, whereas (99m)Tc-HMPAO radiolabelling procedure was carried out in a hot cell with manipulator gloves. This study was conducted to validate this process using a Media Fill simulation test. The study was performed using sterile Tryptic Soy Broth (TSB) in place of active product, reproducing as closely as possible the routine aseptic production process with all the critical steps, as described in the our internal standard operative procedures (SOP). The final vials containing the media of each processed step were then incubated for 14 days and examined for the evidence of microbial growth. No evidence of turbidity was observed in all the steps assayed by the Media Fill. In the separation and labelling of autologous leukocytes with (99m)Tc-HmPAO, Media-Fill test represents a reliable tool to validate the aseptic process. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    Science.gov (United States)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  6. Carotid Artery Stenting in a Patient With a Continuous-Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Piazza, Michele; Squizzato, Francesco; Grego, Franco; Bottio, Tommaso; Gerosa, Gino; Antonello, Michele

    2016-08-01

    To demonstrate the safety and feasibility of carotid artery stenting (CAS) in a patient with a continuous-flow left ventricular assist device (LVAD). A 54-year-old woman with a LVAD was referred for a 90% stenosis of the right internal carotid artery (ICA). The patient was offered CAS, and oral anticoagulant was not discontinued in the periprocedural period. Because of absent arterial pulses, percutaneous transfemoral access was obtained under ultrasound guidance. Particular attention was paid to cannulation of the innominate artery; a 7-F guiding catheter was advanced from the descending aorta into the innominate artery under road-mapping, avoiding maneuvers in the ascending aorta where the outflow Dacron graft of the LVAD was anastomosed. To avoid cerebral flow modifications, the Angioguard RX was used as the cerebral protection device rather than other devices such as the flow reversal or flow-clamping systems. At this point, CAS was performed in a standard fashion using the 7×30-mm Precise ProRX stent. The computed tomography angiogram at 6 months showed patency of the stented right ICA. With adequate planning, CAS appears feasible in patients with a LVAD. © The Author(s) 2016.

  7. A practical review for cardiac rehabilitation professionals of continuous-flow left ventricular assist devices: historical and current perspectives.

    Science.gov (United States)

    Compostella, Leonida; Russo, Nicola; Setzu, Tiziana; Bottio, Tomaso; Compostella, Caterina; Tarzia, Vincenzo; Livi, Ugolino; Gerosa, Gino; Iliceto, Sabino; Bellotto, Fabio

    2015-01-01

    An increasing number of patients with end-stage heart failure are being treated with continuous-flow left ventricular assist devices (cf-LVADs). These patients provide new challenges to the staff in exercise-based cardiac rehabilitation (CR) programs. Even though experience remains limited, it seems that patients supported by cf-LVADs may safely engage in typical rehabilitative activities, provided that some attention is paid to specific aspects, such as the presence of a short external drive line. In spite of initial physical deconditioning, CR allows progressive improvement of symptoms such as fatigue and dyspnea. Intensity of rehabilitative activities should ideally be based on measured aerobic capacity and increased appropriately over time. Regular, long-term exercise training results in improved physical fitness and survival rates. Appropriate adjustment of cf-LVAD settings, together with maintenance of adequate blood volume, provides maximal output, while avoiding suction effects. Ventricular arrhythmias, although not necessarily constituting an immediate life-threatening situation, deserve treatment as they could lead to an increased rate of hospitalization and poorer quality of life. Atrial fibrillation may worsen symptoms of right ventricular failure and reduce exercise tolerance. Blood pressure measurements are possible in cf-LVAD patients only using a Doppler technique, and a mean blood pressure ≤80 mmHg is considered "ideal." Some patients may present with orthostatic intolerance, related to autonomic dysfunction. While exercise training constitutes the basic rehabilitative tool, a comprehensive intervention that includes psychological and social support could better meet the complex needs of patients in which cf-LVAD may offer prolonged survival.

  8. Quantitative measurement of regional cerebral blood flow using {sup 99m}Tc-HM-PAO SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hisashi; Nakamura, Yusaku; Yagi, Yuji; Miura, Kosuke; Takahashi, Mitsuo [Kinki Univ., Osaka-Sayama, Osaka (Japan)

    1994-10-01

    This study examined a simple method for measuring the regional cerebral blood flow (rCBF) using {sup 99m}Tc-HM-PAO SPECT. The mean CBF (mCBF) was determined by the Patlack plot method and rCBF was calculated with Lassen`s correction algorithm, as reported by Matsuda et al. The cerebral hemisphere was employed as the reference region for Lassen`s correction. The reference RI count rate was calculated from the left cerebral hemisphere at the basal ganglia level and the correction factor {alpha} was fixed at 2.0. As a result, rCBF could be measured more easily than by Matsuda`s method. The contribution of age, laterality and gender to the CBF of normal subjects were studied. The mCBF value of 26 normal subjects was 53.8{+-}6.4 ml/100 g/min and showed a significant correlation with advancing age (R=0.644, p=0.0004, n=26). The mean values for rCBF of the cerebellum, frontal area, temporal area, occipital area and parietal area were 77.3{+-}6.6 ml/100 g/min, 70.2{+-}9.1 ml/100 g/min, 72.3{+-}7.5 ml/100 g/min, 71.8{+-}6.2 ml/100 g/min and 73.8{+-}8.6 ml/100 g/min, respectively. There were no gender or laterality differences in the mCBF or respective rCBF values. Each of the above listed regions, except for the occipital area, demonstrated a significant correlation with advancing age. The most remarkable decrease in rCBF with age was noted in the frontal area (R=0.757, p=0.001, n=26). (author).

  9. Impact of long term left ventricular assist device therapy on donor allocation in cardiac transplantation.

    Science.gov (United States)

    Uriel, Nir; Jorde, Ulrich P; Woo Pak, Sang; Jiang, Jeff; Clerkin, Kevin; Takayama, Hiroo; Naka, Yoshifumi; Schulze, P Christian; Mancini, Donna M

    2013-02-01

    Left Ventricular Assist Devices (LVAD) are increasingly used as a bridge to transplant (BTT) for patients with advanced congestive heart failure (CHF) and are assigned United Network for Organ Sharing (UNOS) high priority status (1B or 1A). The purpose of our study was asses the effect of organ allocation in the era of continuous flow pumps. A retrospective chart review was performed of all patients transplanted between 1/2001-1/2011 at Columbia University Medical Center. Seven hundred twenty six adult heart transplantations were performed. Two hundred seventy four BTT patients were implanted with LVAD; of which 227 patients were transplanted. Sixty three patients were transplanted as UNOS-1B, while 164 were transplanted as UNOS-1A (72%). Of these 164 patients, 65 were transplanted during their 30-day 1A period (43%) and 96 after upgrading to UNOS-1A for device complication (56%). For 452 non-device patients 139 (31%) were transplanted as UNOS-1A, 233 as UNOS-1B (52%), and 80 as UNOS-2 (17%). The percentage of patients bridged with LVAD increased from 19% in 2001 to 64% in 2010 while the number transplanted during their 30 day 1A grace period declined from 57% in 2005 to 16% in 2011; i.e. 84% of BTT patients in 2011 needed more than 30 days 1A time to be transplanted. Most LVAD patients are now transplanted while suffering device complication. There was no difference in post transplant survival between LVAD patients transplanted as UNOS 1B, 1A grace period or for a device complication As wait time for cardiac transplantation increased the percentage of patients being bridged to transplant with an LVAD has increased with the majority of them transplanted in the setting of device complication. Copyright © 2013 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  10. The effect of Hominis Placenta Pharmacopuncture on Leg spasticity of stroke patients (A Pilot study, Double blind, Randomized, Controlled Clinical Trial

    Directory of Open Access Journals (Sweden)

    Ju-hwan Noh

    2009-12-01

    Full Text Available Objective : The purpose of this study is to determine the effect of Hominis Placenta Pharmacopuncture(HPP on lower limb spasticity control in stroke patients. Methods : Twenty stroke patients with Leg spasticity were randomly divided into two groups, a Distilled water Pharmacopuncture(group I and a HPP(group II. The number of Pharmacopuncture was 5 times a week and acupuncture treatment was 3 times a week for 3 weeks. Modified Ashworth Scale(MAS, H-reflex/M-response ratio(H/M ratio, Berg Balance Scale(BBS and Time Up & Go(TUG were used for evaluation of spasticity control before experiment, after 1 week, 2 weeks, 3 weeks. Results : Group I showed significant improvement(p<.05 in BBS but no significant improvement in MAS, H/M ratio, and TUG. Group II showed significant improvement(p<.05 in MAS, BBS, and TUG, but no significant improvement in H/M ratio. The results showed significant difference in TUG, but no significant difference in MAS, H/M ratio and BBS between 2 groups. Conclusion : These results showed that HPP might decrease lower limb spasticity and increase leg motor function in stroke patients. Further studies will be required to examine more cases in the long period for the effect on lower limb in spasticity by HPP.

  11. Synthesis and characterisation of Cu(II), Ni(II), Mn(II), Zn(II) and VO(II ...

    Indian Academy of Sciences (India)

    Unknown

    Synthesis and characterisation of Cu(II), Ni(II), Mn(II), Zn(II) and VO(II) Schiff base complexes derived from o-phenylenediamine and acetoacetanilide. N RAMAN*, Y PITCHAIKANI RAJA and A KULANDAISAMY. Department of Chemistry, VHNSN College, Virudhunagar 626 001, India e-mail: ra_man@123india.com.

  12. Biologically active new Fe(II, Co(II, Ni(II, Cu(II, Zn(II and Cd(II complexes of N-(2-thienylmethylenemethanamine

    Directory of Open Access Journals (Sweden)

    C. SPÎNU

    2008-04-01

    Full Text Available Iron(II, cobalt(II, nickel (II, copper (II, zinc(II and cadmium(II complexes of the type ML2Cl2, where M is a metal and L is the Schiff base N-(2-thienylmethylenemethanamine (TNAM formed by the condensation of 2-thiophenecarboxaldehyde and methylamine, were prepared and characterized by elemental analysis as well as magnetic and spectroscopic measurements. The elemental analyses suggest the stoichiometry to be 1:2 (metal:ligand. Magnetic susceptibility data coupled with electronic, ESR and Mössbauer spectra suggest a distorted octahedral structure for the Fe(II, Co(II and Ni(II complexes, a square-planar geometry for the Cu(II compound and a tetrahedral geometry for the Zn(II and Cd(II complexes. The infrared and NMR spectra of the complexes agree with co-ordination to the central metal atom through nitrogen and sulphur atoms. Conductance measurements suggest the non-electrolytic nature of the complexes, except for the Cu(II, Zn(II and Cd(II complexes, which are 1:2 electrolytes. The Schiff base and its metal chelates were screened for their biological activity against Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa and the metal chelates were found to possess better antibacterial activity than that of the uncomplexed Schiff base.

  13. NmF2 and hmF2 measurements at 95° E and 127° E around the EIA northern crest during 2010-2014

    Science.gov (United States)

    Kalita, Bitap Raj; Bhuyan, Pradip Kumar; Yoshikawa, Akimasa

    2015-11-01

    The characteristics of the F2 layer parameters NmF2 and hmF2 over Dibrugarh (27.5° N, 95° E, 17° N geomagnetic, 43° dip) measured by a Canadian Advanced Digital Ionosonde (CADI) for the period of August 2010 to July 2014 are reported for the first time from this low mid-latitude station lying within the daytime peak of the longitudinal wave number 4 structure of equatorial anomaly (EIA) around the northern edge of anomaly crest. Equinoctial asymmetry is clearly observed at all solar activity levels whereas the midday winter anomaly is observed only during high solar activity years and disappears during the temporary dip in solar activity in 2013 but forenoon winter anomaly can be observed even at moderate solar activity. The NmF2/hmF2 variations over Dibrugarh are compared with that of Okinawa (26.5° N, 127° E, 17° N geomagnetic), and the eastward propagation speed of the wave number 4 longitudinal structure from 95° E to 127° E is estimated. The speed is found to be close to the theoretical speed of the wave number 4 (WN4) structure. The correlation of daily NmF2 over Dibrugarh and Okinawa with solar activity exhibits diurnal and seasonal variations. The highest correlation in daytime is observed during the forenoon hours in equinox. The correlation of daily NmF2 (linear or non-linear) with solar activity exhibits diurnal variation. A tendency for amplification with solar activity is observed in the forenoon and late evening period of March equinox and the postsunset period of December solstice. NmF2 saturation effect is observed only in the midday period of equinox. Non-linear variation of neutral composition at higher altitudes and variation of recombination rates with solar activity via temperature dependence may be related to the non-linear trend. The noon time maximum NmF2 over Dibrugarh exhibits better correlation with equatorial electrojet (EEJ) than with solar activity and, therefore, new low-latitude NmF2 index is proposed taking both solar

  14. Complexes of cobalt(II), nickel(II), copper(II), zinc(II), cadmium(II) and dioxouranium(II) with thiophene-2-aldehydethiosemicarbazone

    International Nuclear Information System (INIS)

    Singh, Balwan; Misra, Harihar

    1986-01-01

    Metal complexes of thiosemicarbazides have been known for their pharmacological applications. Significant antitubercular, fungicidal and antiviral activities have been reported for thiosemicarbazides and their derivatives. The present study describes the systhesis and characterisation of complexes of Co II , Cu II , Zn II ,Cd II and UO II with thiosemicarbazone obtained by condensing thiophene-2-aldehyde with thiosemicarbazide. 17 refs., 2 tables. (author)

  15. Cranial MR imaging and cerebral 99mTc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    International Nuclear Information System (INIS)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-01-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and 99m Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOX) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS = III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (au) (18 refs.)

  16. Cranial MR imaging and cerebral 99mTc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    International Nuclear Information System (INIS)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-01-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and 99m Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOS) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS=III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (orig.)

  17. Design Report for a 19-pin carbide test-bundle in a ring-subassembly of the test zone of KNK II/2

    International Nuclear Information System (INIS)

    Haefner, H.E.

    1982-03-01

    This report describes a 19-rod carbide test bundle in an annular oxide ring element placed at the position 201 of the test zone in the second core of KNK II as well as its behavior during the period of operation. The selected fuel rod concept includes low pellet density and a relatively large gap width as well as helium bonding between fuel and cladding. Characteristic design and operation data are: rod diameter 8.5 mm, pellet diameter 7.0 mm, maximum nominal linear rating 800 W/cm, maximum nominal burnup 70 MWd/kgHM. This report exclusively deals with the carbide test bundle and its individual components; it describes methods, criteria and results concerning the design. The annular carrier element with its head and foot is treated in a separate report. The loadability of the test bundle and its individual components is demonstrated by generally valid standards for strength criteria [de

  18. Minimally Invasive Implantation of HeartWare Assist Device and Simultaneous Tricuspid Valve Reconstruction Through Partial Upper Sternotomy.

    Science.gov (United States)

    Hillebrand, Julia; Hoffmeier, Andreas; Djie Tiong Tjan, Tonny; Sindermann, Juergen R; Schmidt, Christoph; Martens, Sven; Scherer, Mirela

    2017-05-01

    Left ventricular assist device (LVAD) implantation is a well-established therapy to support patients with end-stage heart failure. However, the operative procedure is associated with severe trauma. Third generation LVADs like the HeartWare assist device (HeartWare, Inc., Framingham, MA, USA) are characterized by enhanced technology despite smaller size. These devices offer new minimally invasive surgical options. Tricuspid regurgitation requiring valve repair is frequent in patients with the need for mechanical circulatory support as it is strongly associated with ischemic and nonischemic cardiomyopathy. We report on HeartWare LVAD implantation and simultaneous tricuspid valve reconstruction through minimally invasive access by partial upper sternotomy to the fifth left intercostal space. Four male patients (mean age 51.72 ± 11.95 years) suffering from chronic heart failure due to dilative (three patients) and ischemic (one patient) cardiomyopathy and also exhibiting concomitant tricuspid valve insufficiency due to annular dilation underwent VAD implantation and tricuspid valve annuloplasty. Extracorporeal circulation was established via the ascending aorta, superior vena cava, and right atrium. In all four cases the LVAD implantation and tricuspid valve repair via partial median sternotomy was successful. During the operative procedure, no conversion to full sternotomy was necessary. One patient needed postoperative re-exploration because of pericardial effusion. No postoperative focal neurologic injury was observed. New generation VADs are advantageous because of the possibility of minimally invasive implantation procedure which can therefore minimize surgical trauma. Concomitant tricuspid valve reconstruction can also be performed simultaneously through partial upper sternotomy. Nevertheless, minimally invasive LVAD implantation is a challenging operative technique. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals

  19. Developmental Trajectories of Hand Movements in Typical Infants and Those at Risk of Developmental Disorders: An Observational Study of Kinematics during the First Year of Life

    Directory of Open Access Journals (Sweden)

    Lisa Ouss

    2018-02-01

    are significantly associated with age in cohorts of typical and at-risk infantsdiffer significantly at 5–6 months of age, depending on the context: relating either with an object or a person.Environmental and developmental factors shape the developmental trajectories of hand movements in different cohorts: environment for infants with VIMs; stage of development for premature infants and those with West syndrome; and both factors for infants with orality disorders.The curvature of hand movements specifically reflects atypical development in infants with West syndrome when developmental age is considered.We aimed to discriminate between typical and atypical developmental trajectory patterns of at-risk infants in an interactive setting in this observational and longitudinal study, with the assumption that hand movements (HM reflect preverbal communication and its disorders. We examined the developmental trajectories of HM in five cohorts of at-risk infants and one control cohort, followed from ages 2 to 10 months: 25 West syndrome (WS, 13 preterm birth (PB, 16 orality disorder (OD, 14 with visually impaired mothers (VIM, 7 early hospitalization (EH, and 19 typically developing infants (TD. Video-recorded data were collected in three different structured interactive contexts. Descriptors of the hand motion were used to examine the extent to which HM were associated with age and cohort. We obtained four principal results: (i the kinematics of HM (spatial use, curvature, acceleration, and velocity were significantly associated with age in all cohorts; (ii HM significantly differed at 5–6 months of age in TD infants, depending on the context; (iii environmental and developmental factors shaped the developmental trajectories of HM in different cohorts: environment for VIM, development for PB and WS, and both factors for OD and; (iv the curvatures of HM showed atypical development in WS infants when developmental age was considered. These findings support the importance

  20. Mn(II), Zn(II) and VO(II) Schiff

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 113; Issue 3. Synthesis and characterisation of Cu(II), Ni(II), Mn(II), Zn(II) and VO(II) Schiff base complexes derived from o-phenylenediamine and acetoacetanilide. N Raman Y Pitchaikani Raja A Kulandaisamy. Inorganic Volume 113 Issue 3 June 2001 pp 183-189 ...

  1. Current Trends in Implantable Left Ventricular Assist Devices

    Directory of Open Access Journals (Sweden)

    Jens Garbade

    2011-01-01

    Full Text Available The shortage of appropriate donor organs and the expanding pool of patients waiting for heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. Improved results and the increased applicability and durability with left ventricular assist devices (LVADs have enhanced this treatment option available for end-stage heart failure patients. Moreover, outcome with newer pumps have evolved to destination therapy for such patients. Currently, results using nonpulsatile continuous flow pumps document the evolution in outcomes following destination therapy achieved subsequent to the landmark Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure Trial (REMATCH, as well as the outcome of pulsatile designed second-generation LVADs. This review describes the currently available types of LVADs, their clinical use and outcomes, and focuses on the patient selection process.

  2. Carotid Doppler ultrasound findings in patients with left ventricular assist devices.

    Science.gov (United States)

    Cervini, Patrick; Park, Soon J; Shah, Dipesh K; Penev, Irina E; Lewis, Bradley D

    2010-12-01

    Left ventricular assist devices (LVADs) have been used to treat advanced heart failure refractory to medical management, as bridge therapy to myocardial recovery, as bridge therapy to cardiac transplantation, or as destination therapy for patients with unfavorable transplant candidacy. Neurologic complications are some of the most common and devastating complications in these patients. Preoperative carotid ultrasound is, therefore, a standard evaluation in patients at risk for cerebrovascular disease. Postoperative carotid artery Doppler sonography is performed in those patients with neurologic symptoms. It is likely, therefore, that sonographers, radiologists, and other physicians working in a center where LVADs are implanted will likely encounter a carotid artery Doppler study in this patient group. To our knowledge, the carotid Doppler findings in these patients have never been published. We review the Doppler ultrasound findings in 6 patients after LVAD insertion.

  3. Adsorption of Pb(II), Cu(II), Cd(II), Zn(II), Ni(II), Fe(II), and As(V) on bacterially produced metal sulfides.

    Science.gov (United States)

    Jong, Tony; Parry, David L

    2004-07-01

    The adsorption of Pb(II), Cu(II), Cd(II), Zn(II), Ni(II), Fe(II) and As(V) onto bacterially produced metal sulfide (BPMS) material was investigated using a batch equilibrium method. It was found that the sulfide material had adsorptive properties comparable with those of other adsorbents with respect to the specific uptake of a range of metals and, the levels to which dissolved metal concentrations in solution can be reduced. The percentage of adsorption increased with increasing pH and adsorbent dose, but decreased with increasing initial dissolved metal concentration. The pH of the solution was the most important parameter controlling adsorption of Cd(II), Cu(II), Fe(II), Ni(II), Pb(II), Zn(II), and As(V) by BPMS. The adsorption data were successfully modeled using the Langmuir adsorption isotherm. Desorption experiments showed that the reversibility of adsorption was low, suggesting high-affinity adsorption governed by chemisorption. The mechanism of adsorption for the divalent metals was thought to be the formation of strong, inner-sphere complexes involving surface hydroxyl groups. However, the mechanism for the adsorption of As(V) by BPMS appears to be distinct from that of surface hydroxyl exchange. These results have important implications to the management of metal sulfide sludge produced by bacterial sulfate reduction.

  4. Synoptic evaluation of modelled and bioindicated atmospheric deposition of heavy metals in forests; Synoptische Auswertung modellierter atmosphaerischer Eintraege von Schwermetallen und deren Indikation durch Biomonitore in Waeldern

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, Stefan; Schroeder, Winfried [Vechta Univ. (Germany). Lehrstuhl fuer Landschaftsoekologie; Fries, Caroline [PlanWerk - Buero fuer oekologische Fachplanungen, Nidda (Germany)

    2017-03-15

    Heavy metals (HM) concentrations in moss, leaves and needles and organic surface soil layers, derived from the European Moss Survey, the German Environmental Specimen Bank (ESB) and the ICP Forests were compared with those from deposition modelling by use of LOTOS-EUROS (LE) and EMEP/MSCE-HM in terms of their spatial patterns and temporal trends. The total atmospheric deposition differs considerably between the two models. HM concentrations in biomonitors (moss, leaves, and needles) were found to be predominantly higher correlated to deposition modelled by LE compared to EMEP. For Cd, strongest correlations could be found between deposition data calculated by LE and concentrations in moss (Europe, geostatistically estimated) and in needles (Germany). Regarding Pb, the coefficients of correlation came out to be the highest for EMEP deposition and measured element concentrations in moss (Europe) as well as for LE deposition and needles from ICP Forests Level II (Germany) and, respectively, leaves from ESB (Germany).

  5. Crescimento do maracujazeiro-doce propagado por sementes em função da calagem Growth of sweet passion fruit seedlings as a function of liming

    Directory of Open Access Journals (Sweden)

    Elda Bonilha Assis Fonseca

    2003-08-01

    Full Text Available Objetivou-se avaliar as respostas em crescimento do maracujazeiro-doce (Passiflora alata Dryand. propagado por sementes, quando cultivado sob diferentes níveis de saturação por bases em solos representativos das regiões produtoras de Minas Gerais. O experimento foi conduzido em casa-de-vegetação do Departamento de Agricultura da Universidade Federal de Lavras-UFLA. Utilizou-se o delineamento experimental de blocos casualizados em esquema fatorial (2 x 4 + 2, com quatro repetições. Os tratamentos envolveram dois solos (LATOSSOLO VERMELHO AMARELO distrófico - LVAd e LATOSSOLO VERMELHO distrófico - LVd, quatro níveis de saturação por bases (40, 60, 80 e 100% mais dois tratamentos adicionais (LVAd sem calagem e LVd sem calagem. Aos 150 dias, determinaram-se o comprimento das hastes, número de folhas por haste, pesos de matéria seca de parte aérea e de raízes e relação raiz/parte aérea. Concluiu-se que, até 150 dias, o maracujazeiro-doce propagado por sementes apresentou maior crescimento vegetativo quando cultivado no LVd, em comparação ao LVAd, com ou sem calagem, e tolerou solos com baixos níveis de saturação por bases; o aumento do nível de saturação por bases no LVd reduziu o crescimento vegetativo do maracujazeiro-doce propagado por sementes, enquanto no LVAd, não influenciou o crescimento vegetativo.ABSTRACT - The objective for this work was to evaluate the growth of sweet passion fruit seedlings (Passiflora alata Dryand. under different base saturation levels in representative soils of Minas Gerais. The experiment was carried in the greenhouse of the Agriculture Department of the Federal University of Lavras (UFLA. The statistical design used was randomized blocks in a factorial scheme (2 x 4 + 2, with four repetitions. The treatments involved two soil classes (Distrophic Red-Yellow Latosol - LVAd and Distrophic Red Latosol - LVd, four base saturation levels (40, 60, 80 and 100% and two more additional treatments

  6. Cranial MR imaging and cerebral [sup 99m]Tc HM-PAO-SPECT in patients with subacute or chronic severe closed head injury and normal CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Wimberger, D.; Oder, W.; Kramer, J.; Schindler, E.; Podreka, I.; Imhof, H.

    1993-11-01

    Eighteen patients in the subacute or chronic state following severe closed head injury with normal cranial CT scans were examined by MR and [sup 99m]Tc HM-PAO SPECT. Correlations were sought between these 2 imaging modalities and the clinical outcome, as defined by the Glasgow Outcome Scale (GOX) score. Both MR and SPECT revealed cerebral damage in all patients examined but structural and functional alterations did not coincide topographically in 64.9% of lesions. Nevertheless, complementary injury patterns suggesting poor recovery were found; cortical contusions and diffuse axonal injury (MR) in conjunction with cortical and thalamic hypoperfusion (SPECT) were noticed in 8 out of 12 patients with unfavorable outcome (GOS = III and IV). The synthesis of MR and SPECT information clearly enhanced the ability both to accurately assess posttraumatic brain damage and to improve patients' outcome prediction. (au) (18 refs.).

  7. Implantable Cardioverter-Defibrillators in Patients With a Continuous-Flow Left Ventricular Assist Device: An Analysis of the INTERMACS Registry.

    Science.gov (United States)

    Clerkin, Kevin J; Topkara, Veli K; Demmer, Ryan T; Dizon, Jose M; Yuzefpolskaya, Melana; Fried, Justin A; Mai, Xingchen; Mancini, Donna M; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Colombo, Paolo C; Garan, A Reshad

    2017-12-01

    This study sought to determine if the presence of implantable cardioverter-defibrillators (ICD) provided a mortality benefit during continuous-flow left ventricular assist device (LVAD) support. An ICD decreases mortality in selected patients with advanced heart failure and have been associated with reduced mortality in patients with pulsatile LVAD. However, it is unclear whether that benefit extends to patients with a contemporary continuous-flow LVAD. Propensity score matching was used to generate a cohort of patients with similar baseline characteristics. The primary outcome was freedom from death during LVAD support. Secondary endpoints included freedom from unexpected death, likelihood of transplantation and recovery, and adverse events. Among 16,384 eligible patients in the Interagency Registry for Mechanically Assisted Circulatory Support registry, 2,209 patients with an ICD and 2,209 patients without one had similar propensity scores and were included. The presence of an ICD was associated with an increased mortality risk (hazard ratio: 1.20; 95% confidence interval [CI]: 1.04 to 1.39; p = 0.013) and an increased risk of unexpected death during device support (HR: 1.33; 95% CI: 1.03 to 1.71; p = 0.03). Patients with an ICD were more likely to undergo transplantation (HR: 1.16; 95% CI: 0.99 to 1.35; p = 0.06) and less likely to have LVAD explant for recovery (HR: 0.53, 95% CI: 0.29 to 0.98; p = 0.04). Patients with an ICD had a higher rate of treated ventricular arrhythmias (rate ratio: 1.27; 95% CI: 1.10 to 1.48; p = 0.001) and rehospitalization (rate ratio: 1.08; 95% CI: 1.04 to 1.12; p < 0.0001), but rates of hemorrhagic stroke were similar (rate ratio: 1.01; 95% CI: 0.81 to 1.26; p = 0.98). Among patients with a continuous flow LVAD, the presence of an ICD was not associated with reduced mortality. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Quality of life and functional capacity outcomes in the MOMENTUM 3 trial at 6 months: A call for new metrics for left ventricular assist device patients.

    Science.gov (United States)

    Cowger, Jennifer A; Naka, Yoshifumi; Aaronson, Keith D; Horstmanshof, Douglas; Gulati, Sanjeev; Rinde-Hoffman, Debbie; Pinney, Sean; Adatya, Sirtaz; Farrar, David J; Jorde, Ulrich P

    2018-01-01

    The Multicenter Study of MAGLEV Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) clinical trial demonstrated improved 6-month event-free survival, but a detailed analysis of health-related quality of life (HR-QOL) and functional capacity (FC) was not presented. Further, the effect of early serious adverse events (SAEs) on these metrics and on the general ability to live well while supported with a left ventricular assist system (LVAS) warrants evaluation. FC (New York Heart Association [NYHA] and 6-minute walk test [6MWT]) and HR-QOL (European Quality of Life [EQ-5D-5L] and the Kansas City Cardiomyopathy [KCCQ]) assessments were obtained at baseline and 6 months after HeartMate 3 (HM3, n = 151; Abbott, Abbott Park, IL) or HeartMate II (HMII, n = 138; Abbott) implant as part of the MOMENTUM 3 clinical trial. Metrics were compared between devices and in those with and without events. The proportion of patients "living well on an LVAS" at 6 months, defined as alive with satisfactory FC (NYHA I/II or 6MWT > 300 meters) and HR-QOL (overall KCCQ > 50), was evaluated. Although the median (25th-75th percentile) patient KCCQ (change for HM3: +28 [10-46]; HMII: +29 [9-48]) and EQ-5D-5L (change for HM3: -1 [-5 to 0]; HMII: -2 [-6 to 0]) scores improved from baseline to 6 months (p 0.05). Likewise, there was an equivalent improvement in 6MWT distance at 6 months in HM3 (+94 [1-274] meters] and HMII (+188[43-340 meters]) from baseline. In patients with SAEs (n = 188), 6MWTs increased from baseline (p < 0.001), but gains for both devices were less than those without SAE (HM3: +74 [-9 to 183] meters with SAE vs +140 [35-329] meters without SAE; HMII: +177 [47-356] meters with SAE vs +192 [23-337] meters without SAE, both p < 0.003). SAEs did not affect the 6-month HR-QOL scores. The "living well" end point was achieved in 145 HM3 (63%) and 120 HMII (68%) patients (p = 0.44). Gains in HR-QOL and FC were similar early after HM3

  9. Synthesis and spectroscopic studies of biologically active tetraazamacrocyclic complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II

    Directory of Open Access Journals (Sweden)

    Monika Tyagi

    2014-01-01

    Full Text Available Complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II were synthesized with the macrocyclic ligand, i.e., 2,3,9,10-tetraketo-1,4,8,11-tetraazacycoletradecane. The ligand was prepared by the [2 + 2] condensation of diethyloxalate and 1,3-diamino propane and characterized by elemental analysis, mass, IR and 1H NMR spectral studies. All the complexes were characterized by elemental analysis, molar conductance, magnetic susceptibility measurements, IR, electronic and electron paramagnetic resonance spectral studies. The molar conductance measurements of Mn(II, Co(II and Ni(II complexes in DMF correspond to non electrolyte nature, whereas Pd(II and Pt(II complexes are 1:2 electrolyte. On the basis of spectral studies an octahedral geometry has been assigned for Mn(II, Co(II and Ni(II complexes, whereas square planar geometry assigned for Pd(II and Pt(II. In vitro the ligand and its metal complexes were evaluated against plant pathogenic fungi (Fusarium odum, Aspergillus niger and Rhizoctonia bataticola and some compounds found to be more active as commercially available fungicide like Chlorothalonil.

  10. Validation of KENOREST with LWR-PROTEUS phase II samples

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, M.; Kilger, R.; Pautz, A.; Zwermann, W. [GRS, Garching (Germany); Grimm, P.; Vasiliev, A.; Ferroukhi, H. [Paul Scherrer Institut, Villigen (Switzerland)

    2012-11-01

    In order to broaden the validation basis of the reactivity and nuclide inventory code KENOREST two samples of the LWR-PROTEUS phase II program have been calculated and compared to the experimental results. In general most nuclides are reproduced very well and agree within about ten percent with the experiment. Some already known problems, the overprediction of metallic fission products and the underprediction of the higher curium isotopes, have been confirmed. One of the largest uncertainties in the calculation was the burnup of the samples due to differences between a core simulation of the fuel vendor and the burnup determined from the measured values of the burnup indicator Nd-148. Two different models taking into account the environment for a peripheral fuel rod have been studied. The more detailed model included the three direct neighbor fuel assemblies depleted along with the fuel rod of interest. The influence on the results has been found to be very small. Compared to the uncertainties from the burnup, this effect can be considered negligible. The reason for the low influence was basically that the spectrum did not get considerably harder with increasing burnup beyond about 20GWd/tHM. Since the sample reached burnups far beyond that value, an effect could not be seen. In the near future an update of the used libraries is planned and it will be very interesting to study the effect on the results, especially for Curium. (orig.)

  11. Discontinuation of antithrombotic therapy for a year or more in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Pereira, Naveen L; Chen, Dong; Kushwaha, Sudhir S; Park, Soon J

    2010-10-01

    The recommended anticoagulation regimen during continuous-flow axial left ventricular assist device (LVAD) support is aspirin and warfarin with a targeted international normalized ratio of 2.0-3.0. We report two patients in whom recurrent gastrointestinal bleeding during LVAD support necessitated discontinuation of this anti-thrombotic regimen for a year or more. Despite this, neither patients developed thrombotic complications during 29 patient-months of follow-up. An acquired von Willebrand factor (VWF) abnormality reflected by the absence or decreased abundance of the highest molecular weight multimers was demonstrated in both patients. The gold standard test for platelet function, light transmission platelet aggregometry was measured in one patient and was normal, indicative that the predominant abnormality in the coagulation profile of these patients is an acquired VWF syndrome. Clinical trials are required to address the question whether it is safe to discontinue anticoagulation in LVAD patients with acquired VWF abnormalities.

  12. The Impact of Socioeconomic Status on Patients Supported with a Left Ventricular Assist Device: An Analysis of the UNOS Database

    Science.gov (United States)

    Clerkin, Kevin J.; Garan, A. Reshad; Wayda, Brian; Givens, Raymond C.; Yuzefpolskaya, Melana; Nakagawa, Shunichi; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Mancini, Donna M.; Colombo, Paolo C.; Topkara, Veli K.

    2016-01-01

    Background Low socioeconomic status (SES) is a known risk factor for heart failure, mortality among those with heart failure, and poor post heart transplant (HT) outcomes. This study sought to determine if SES is associated with decreased waitlist survival while on LVAD support and after HT. Methods and Results 3,361 adult patients bridged to primary HT with an LVAD between May 2004 and April 2014 were identified in the UNOS database. SES was measured using the AHRQ SES index using data from the 2014 American Community Survey. In the study cohort, SES did not have an association with the combined endpoint of death or delisting on LVAD support (p=0.30). In a cause-specific unadjusted model, those in the top (HR 1.55, 95% CI 1.14–2.11, p=0.005) and second greatest SES quartile (HR 1.50, 95% CI 1.10–2.04, p=0.01) had an increased risk of death on device support compared to the lowest SES quartile. Adjusting for clinical risk factors mitigated the increased risk. There was no association between SES and complications. Post-HT survival, both crude and adjusted, was decreased for patients in the lowest quartile of SES index compared to all other SES quartiles. Conclusions Freedom from waitlist death or delisting was not impacted by SES. Patients with a higher SES had an increased unadjusted risk of waitlist mortality during LVAD support, which was mitigated by adjusting for increased comorbid conditions. Low SES was associated with worse post-HT outcomes. Further study is needed to confirm and understand a differential effect of SES on post-transplant outcomes that was not seen during LVAD support prior to HT. PMID:27758810

  13. Impact of Socioeconomic Status on Patients Supported With a Left Ventricular Assist Device: An Analysis of the UNOS Database (United Network for Organ Sharing).

    Science.gov (United States)

    Clerkin, Kevin J; Garan, Arthur Reshad; Wayda, Brian; Givens, Raymond C; Yuzefpolskaya, Melana; Nakagawa, Shunichi; Takeda, Koji; Takayama, Hiroo; Naka, Yoshifumi; Mancini, Donna M; Colombo, Paolo C; Topkara, Veli K

    2016-10-01

    Low socioeconomic status (SES) is a known risk factor for heart failure, mortality among those with heart failure, and poor post heart transplant (HT) outcomes. This study sought to determine whether SES is associated with decreased waitlist survival while on left ventricular assist device (LVADs) support and after HT. A total of 3361 adult patients bridged to primary HT with an LVAD between May 2004 and April 2014 were identified in the UNOS database (United Network for Organ Sharing). SES was measured using the Agency for Healthcare Research and Quality SES index using data from the 2014 American Community Survey. In the study cohort, SES did not have an association with the combined end point of death or delisting on LVAD support (P=0.30). In a cause-specific unadjusted model, those in the top (hazard ratio, 1.55; 95% confidence interval, 1.14-2.11; P=0.005) and second greatest SES quartile (hazard ratio 1.50; 95% confidence interval, 1.10-2.04; P=0.01) had an increased risk of death on device support compared with the lowest SES quartile. Adjusting for clinical risk factors mitigated the increased risk. There was no association between SES and complications. Post-HT survival, both crude and adjusted, was decreased for patients in the lowest quartile of SES index compared with all other SES quartiles. Freedom from waitlist death or delisting was not affected by SES. Patients with a higher SES had an increased unadjusted risk of waitlist mortality during LVAD support, which was mitigated by adjusting for increased comorbid conditions. Low SES was associated with worse post-HT outcomes. Further study is needed to confirm and understand a differential effect of SES on post-transplant outcomes that was not seen during LVAD support before HT. © 2016 American Heart Association, Inc.

  14. Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol.

    Science.gov (United States)

    Heatley, Gerald; Sood, Poornima; Goldstein, Daniel; Uriel, Nir; Cleveland, Joseph; Middlebrook, Don; Mehra, Mandeep R

    2016-04-01

    The HeartMate 3 left ventricular assist system (LVAS; St. Jude Medical, Inc., formerly Thoratec Corporation, Pleasanton, CA) was recently introduced into clinical trials for durable circulatory support in patients with medically refractory advanced-stage heart failure. This centrifugal, fully magnetically levitated, continuous-flow pump is engineered with the intent to enhance hemocompatibility and reduce shear stress on blood elements, while also possessing intrinsic pulsatility. Although bridge-to-transplant (BTT) and destination therapy (DT) are established dichotomous indications for durable left ventricular assist device (LVAD) support, clinical practice has challenged the appropriateness of these designations. The introduction of novel LVAD technology allows for the development of clinical trial designs to keep pace with current practices. The prospective, randomized Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) clinical trial aims to evaluate the safety and effectiveness of the HeartMate 3 LVAS by demonstrating non-inferiority to the HeartMate II LVAS (also St. Jude Medical, Inc.). The innovative trial design includes patients enrolled under a single inclusion and exclusion criteria , regardless of the intended use of the device, with outcomes ascertained in the short term (ST, at 6 months) and long term (LT, at 2 years). This adaptive trial design includes a pre-specified safety phase (n = 30) analysis. The ST cohort includes the first 294 patients and the LT cohort includes the first 366 patients for evaluation of the composite primary end-point of survival to transplant, recovery or LVAD support free of debilitating stroke (modified Rankin score >3), or re-operation to replace the pump. As part of the adaptive design, an analysis by an independent statistician will determine whether sample size adjustment is required at pre-specified times during the study. A further 662

  15. Is anti-platelet therapy needed in continuous flow left ventricular assist device patients? A single-centre experience.

    Science.gov (United States)

    Litzler, Pierre-Yves; Smail, Hassiba; Barbay, Virginie; Nafeh-Bizet, Catherine; Bouchart, François; Baste, Jean-Marc; Abriou, Caroline; Bessou, Jean-Paul

    2014-01-01

    We report our 5-year experience of continuous flow left ventricular assist device (LVAD) implantation without the use of anti-platelet therapy. Between February 2006 and September 2011, 27 patients (26 men; 1 woman) were implanted with a continuous flow LVAD (HeartMate II, Thoratec Corporation, Pleasanton, CA, USA). The mean age was 55.7 ± 9.9 years. The mean duration of support was 479 ± 436 (1-1555) days with 35.4 patient-years on support. Twenty-one patients were implanted as a bridge to transplantation and 6 for destination therapy. The anticoagulation regimen was fluindione for all patients, with aspirin for only 4 patients. At the beginning of our experience, aspirin was administered to 4 patients for 6, 15, 60 and 460 days. Due to gastrointestinal (GI) bleeding and epistaxis, aspirin was discontinued, and since August 2006, no patients have received anti-platelet therapy. At 3 years, the survival rate during support was 76%. The most common postoperative adverse event was GI bleeding (19%) and epistaxis (30%) (median time: 26 days) for patients receiving fluindione and aspirin. The mean International Normalized Ratio (INR) was 2.58 ± 0.74 during support. Fifteen patients have been tested for acquired Von Willebrand disease. A diminished ratio of collagen-binding capacity and ristocetin cofactor activity to Von Willebrand factor antigen was observed in 7 patients. In the postoperative period, 2 patients presented with ischaemic stroke at 1 and 8 months. One of these 2 patients had a previous history of carotid stenosis with ischaemic stroke. There were no patients with haemorrhagic stroke, transient ischaemic attack or pump thrombosis. The event rate of stroke (ischaemic and haemorrhagic) per patient-year was 0.059 among the patients without aspirin with fluindione regimen only. A fluindione regimen without aspirin in long-duration LVAD support appears to not increase thromboembolic events and could lead to a diminished risk of haemorrhagic stroke.

  16. Mechanical Circulatory Support for Advanced Heart Failure: Are We about to Witness a New "Gold Standard"?

    Science.gov (United States)

    Capoccia, Massimo

    2016-12-12

    The impact of left ventricular assist devices (LVADs) for the treatment of advanced heart failure has played a significant role as a bridge to transplant and more recently as a long-term solution for non-eligible candidates. Continuous flow left ventricular assist devices (CF-LVADs), based on axial and centrifugal design, are currently the most popular devices in view of their smaller size, increased reliability and higher durability compared to pulsatile flow left ventricular assist devices (PF-LVADs). The trend towards their use is increasing. Therefore, it has become mandatory to understand the physics and the mathematics behind their mode of operation for appropriate device selection and simulation set up. For this purpose, this review covers some of these aspects. Although very successful and technologically advanced, they have been associated with complications such as pump thrombosis, haemolysis, aortic regurgitation, gastro-intestinal bleeding and arterio-venous malformations. There is perception that the reduced arterial pulsatility may be responsible for these complications. A flow modulation control approach is currently being investigated in order to generate pulsatility in rotary blood pumps. Thrombus formation remains the most feared complication that can affect clinical outcome. The development of a preoperative strategy aimed at the reduction of complications and patient-device suitability may be appropriate. Patient-specific modelling based on 3D reconstruction from CT-scan combined with computational fluid dynamic studies is an attractive solution in order to identify potential areas of stagnation or challenging anatomy that could be addressed to achieve the desired outcome. The HeartMate II (axial) and the HeartWare HVAD (centrifugal) rotary blood pumps have been now used worldwide with proven outcome. The HeartMate III (centrifugal) is now emerging as the new promising device with encouraging preliminary results. There are now enough pumps on

  17. Mechanical Circulatory Support for Advanced Heart Failure: Are We about to Witness a New “Gold Standard”?

    Directory of Open Access Journals (Sweden)

    Massimo Capoccia

    2016-12-01

    Full Text Available The impact of left ventricular assist devices (LVADs for the treatment of advanced heart failure has played a significant role as a bridge to transplant and more recently as a long-term solution for non-eligible candidates. Continuous flow left ventricular assist devices (CF-LVADs, based on axial and centrifugal design, are currently the most popular devices in view of their smaller size, increased reliability and higher durability compared to pulsatile flow left ventricular assist devices (PF-LVADs. The trend towards their use is increasing. Therefore, it has become mandatory to understand the physics and the mathematics behind their mode of operation for appropriate device selection and simulation set up. For this purpose, this review covers some of these aspects. Although very successful and technologically advanced, they have been associated with complications such as pump thrombosis, haemolysis, aortic regurgitation, gastro-intestinal bleeding and arterio-venous malformations. There is perception that the reduced arterial pulsatility may be responsible for these complications. A flow modulation control approach is currently being investigated in order to generate pulsatility in rotary blood pumps. Thrombus formation remains the most feared complication that can affect clinical outcome. The development of a preoperative strategy aimed at the reduction of complications and patient-device suitability may be appropriate. Patient-specific modelling based on 3D reconstruction from CT-scan combined with computational fluid dynamic studies is an attractive solution in order to identify potential areas of stagnation or challenging anatomy that could be addressed to achieve the desired outcome. The HeartMate II (axial and the HeartWare HVAD (centrifugal rotary blood pumps have been now used worldwide with proven outcome. The HeartMate III (centrifugal is now emerging as the new promising device with encouraging preliminary results. There are now

  18. Left ventricular assist device: exercise capacity evolution and rehabilitation added value.

    Science.gov (United States)

    Lamotte, Michel X; Chimenti, Sara; Deboeck, Gael; Gillet, Alexis; Kacelenenbogen, Raymond; Strapart, Jonathan; Vandeneynde, Frédéric; Van Nooten, Guido; Antoine, Martine

    2018-06-01

    With more than 15,000 implanted patients worldwide and a survival rate of 80% at 1-year and 59% at 5-years, left ventricular assist device (LVAD) implantation has become an interesting strategy in the management of heart failure patients who are resistant to other kinds of treatment. There are limited data in the literature on the change over time of exercise capacity in LVAD patients, as well as limited knowledge about the beneficial effects that rehabilitation might have on these patients. Therefore, the aim of our study was to evaluate the evolution of exercise capacity on a cohort of patients implanted with the same device (HeartWare © ) and to analyse the potential impact of rehabilitation. Sixty-two patients implanted with a LVAD between June 2011 and June 2015 were screened. Exercise capacity was evaluated by cardiopulmonary exercise testing at 6 weeks, 6 and 12 months after implantation. We have observed significant differences in the exercise capacity and evolution between the trained and non-trained patients. Some of the trained patients nearly normalised their exercise capacity at the end of the rehabilitation programme. Exercise capacity of patient implanted with a HeartWare © LVAD increased in the early period after implantation. Rehabilitation allowed implanted patients to have a significantly better evolution compared to non-rehabilitated patients.

  19. Batibo, HM

    African Journals Online (AJOL)

    Fighting A Losing Battle: Assessing The Impact Of Mother-Tongue Education Advocacy In A Hostile Environment Abstract · Vol 23 (2013) - Articles The Last Kick of a Dying Horse: Preserving Ethnic Identity in Shisukuma Greeting System Abstract · Vol 26 (2015) - Articles Ten commandments for Setswana to be a resourceful ...

  20. Effect of Cu(II), Cd(II) and Zn(II) on Pb(II) biosorption by algae Gelidium-derived materials.

    Science.gov (United States)

    Vilar, Vítor J P; Botelho, Cidália M S; Boaventura, Rui A R

    2008-06-15

    Biosorption of Pb(II), Cu(II), Cd(II) and Zn(II) from binary metal solutions onto the algae Gelidium sesquipedale, an algal industrial waste and a waste-based composite material was investigated at pH 5.3, in a batch system. Binary Pb(II)/Cu(II), Pb(II)/Cd(II) and Pb(II)/Zn(II) solutions have been tested. For the same equilibrium concentrations of both metal ions (1 mmol l(-1)), approximately 66, 85 and 86% of the total uptake capacity of the biosorbents is taken by lead ions in the systems Pb(II)/Cu(II), Pb(II)/Cd(II) and Pb(II)/Zn(II), respectively. Two-metal results were fitted to a discrete and a continuous model, showing the inhibition of the primary metal biosorption by the co-cation. The model parameters suggest that Cd(II) and Zn(II) have the same decreasing effect on the Pb(II) uptake capacity. The uptake of Pb(II) was highly sensitive to the presence of Cu(II). From the discrete model it was possible to obtain the Langmuir affinity constant for Pb(II) biosorption. The presence of the co-cations decreases the apparent affinity of Pb(II). The experimental results were successfully fitted by the continuous model, at different pH values, for each biosorbent. The following sequence for the equilibrium affinity constants was found: Pb>Cu>Cd approximately Zn.

  1. Fluoroscopy-Guided Resolution of Ingested Thrombus Leading to Functional Disturbance of a Continuous-Flow Left Ventricular Assist Device

    Directory of Open Access Journals (Sweden)

    Jens Garbade

    2012-01-01

    Full Text Available The third generation of left ventricular assist devices (LVADs has been shown to improve outcome and quality of life in patients suffering from acute and chronic heart failure. However, VAD-associated complications are still a challenge in the clinical practice. Here we report the resolution of a mobile thrombus formation in the proximity of the inflow cannula of a third generation of LVADs (HVAD Pump, HeartWare, Inc. in a patient with chronic heart failure 4 months after implantation.

  2. Assessment of cardiac sympathetic nerve activity in children with chronic heart failure using quantitative iodine-123 metaiodobenzylguanidine imaging

    Energy Technology Data Exchange (ETDEWEB)

    Karasawa, Kensuke; Ayusawa, Mamoru; Noto, Nobutaka; Sumitomo, Naokata; Okada, Tomoo; Harada, Kensuke [Nihon Univ., Tokyo (Japan). School of Medicine

    2000-12-01

    Cardiac sympathetic nerve activity in children with chronic heart failure was examined by quantitative iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging in 33 patients aged 7.5{+-}6.1 years (range 0-18 years), including 8 with cardiomyopathy, 15 with congenital heart disease, 3 with anthracycrine cardiotoxicity, 3 with myocarditis, 3 with primary pulmonary hypertension and 1 with Pompe's disease. Anterior planar images were obtained 15 min and 3 hr after the injection of iodine-123 MIBG. The cardiac iodine-123 MIBG uptake was assessed as the heart to upper mediastinum uptake activity ratio of the delayed image (H/M) and the cardiac percentage washout rate (%WR). The severity of chronic heart failure was class I (no medication) in 8 patients, class II (no symptom with medication) in 9, class III (symptom even with medication) in 10 and class IV (late cardiac death) in 6. H/M was 2.33{+-}0.22 in chronic heart failure class I, 2.50{+-}0.34 in class II, 1.95{+-}0.61 in class III, and 1.39{+-}0.29 in class IV (p<0.05). %WR was 24.8{+-}12.8% in chronic heart failure class I, 23.3{+-}10.2% in class II, 49.2{+-}24.5% in class III, and 66.3{+-}26.5% in class IV (p<0.05). The low H/M and high %WR were proportionate to the severity of chronic heart failure. Cardiac iodine-123 MIBG showed cardiac adrenergic neuronal dysfunction in children with severe chronic heart failure. Quantitative iodine-123 MIBG myocardial imaging is clinically useful as a predictor of therapeutic outcome and mortality in children with chronic heart failure. (author)

  3. Modification of a Volume-Overload Heart Failure Model to Track Myocardial Remodeling and Device-Related Reverse Remodeling

    Science.gov (United States)

    Tuzun, Egemen; Bick, Roger; Kadipasaoglu, Cihan; Conger, Jeffrey L.; Poindexter, Brian J.; Gregoric, Igor D.; Frazier, O. H.; Towbin, Jeffrey A.; Radovancevic, Branislav

    2011-01-01

    Purpose. To provide an ovine model of ventricular remodeling and reverse remodeling by creating congestive heart failure (CHF) and then treating it by implanting a left ventricular assist device (LVAD). Methods. We induced volume-overload heart failure in 2 sheep; 20 weeks later, we implanted an LVAD and assessed recovery 11 weeks thereafter. We examined changes in histologic and hemodynamic data and levels of cellular markers of CHF. Results. After CHF induction, we found increases in LV end-diastolic pressure, LV systolic and diastolic dimensions, wall thickness, left atrial diameter, and atrial natriuretic protein (ANP) and endothelin-1 (ET-1) levels; β-adrenergic receptor (BAR) and dystrophin expression decreased markedly. Biopsies confirmed LV remodeling. After LVAD support, LV systolic and diastolic dimensions, wall thickness, and mass, and ANP and ET-1 levels decreased. Histopathologic and hemodynamic markers improved, and BAR and dystrophin expression normalized. Conclusions. We describe a successful sheep model for ventricular and reverse remodeling. PMID:22347659

  4. Physicochemical properties of 3,4,5-trimethoxybenzoates of Mn(II, Co(II, Ni(II and Zn(II

    Directory of Open Access Journals (Sweden)

    W. FERENC

    2005-09-01

    Full Text Available The complexes of Mn(II, Co(II, Ni(II, Cu(II and Zn(II with 3,4,5-trimethoxybenzoic acid anion of the formula: M(C10H11O52·nH2O, where n = 6 for Ni(II, n = 1 for Mn(II, Co(II, Cu(II, and n = 0 for Zn, have been synthesized and characterized by elemental analysis, IR spectroscopy, X–ray diffraction measurements, thermogravimetry and magnetic studies. They are crystalline compounds characterized by various symmetry. They decompose in various ways when heated in air to 1273 K. At first, they dehydrate in one step and form anhydrous salts. The final products of decomposition are oxides of the respective metals (Mn2O3, Co3O4, NiO, CuO, ZnO. The solubilities of the analysed complexes in water at 293 K are in the orders of 10-2 – 10-4 mol dm-3. The magnetic susceptibilities of the Mn(II, Co(II, Ni(II and Cu(II complexes were measured over the range of 76–303 K and the magnetic moments were calculated. The results show that the 3,4,5-trimethoxybenzoates of Mn(II, Co(II and Ni(II are high-spin complexes but that of Cu(II forms a dimer [Cu2(C10H11O54(H2O2]. The carboxylate groups bind as monodentate or bidentate chelating or bridging ligands.

  5. Variability in the maximum height of the ionospheric F2-layer over Millstone Hill (September 1998–March 2000; influence from below and above

    Directory of Open Access Journals (Sweden)

    D. Pancheva

    2002-11-01

    Full Text Available The basic aim of this ‘case study’ is to investigate the variability in the maximum height of the ionospheric F2-layer, hmF2, with periods of planetary waves (2–30 days, and to make an attempt to determine their origin. The hourly data of hmF2 above Millstone Hill (42.6° N, 71.5° W during 01 September 1998 - 31 March 2000 were used for analysis. Three types of disturbances are studied in detail: (i the 27- day oscillations observed in the hmF2 above Millstone Hill are generated by the geomagnetic activity and by the global-scale 27-day wave present in the zonal mesosphere/lower thermosphere (MLT neutral wind. The time delay between the 27-day oscillation in the zonal wind and that in the hmF2 is found to be 5–6 days, while between the 27-day oscillation in the geomagnetic activity and that in the hmF2 is found to be 0.8–1 day; (ii the 16-day oscillation in the hmF2 observed during summer 1999 is probably generated by the global scale 16-day modulation of the semidiurnal tide observed in the MLT region during PSMOS campaign in June–August. We found that if the modulated semidiurnal tide mediates the planetary wave signature in the ionosphere, this planetary wave oscillation has to be best expressed in the amplitude and in the phase of the 12-h periodicity of the ionosphere; and (iii the third type of disturbances studied is the quasi-2- day activity in the hmF2 that increases during geomagnetic disturbances. The strong pseudo diurnal periodicities generated during the geomagnetic storms can interact between each other and produce the quasi-2-day oscillations in the ionosphere.Key words. Ionosphere (ionosphere-atmosphere interactions; ionosphere-magnetoshpere interactions; wave propagation

  6. Synthesis and spectral studies of manganese(II), cobalt(II), nickel(II), copper(II), zinc(II), cadmium(II) and mercury(II) complexes of 4-oxo-4H-1-benzopyran-3-carboxaldehyde hydrazone derivatives

    International Nuclear Information System (INIS)

    Nawar, N.; Khattab, M.A.; Bekheit, M.M.; El-Kaddah, A.H.

    1996-01-01

    A few complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II) with 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-chlorobenzylhydrazone) (BCBH) and 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-methylbenzylhydrazone) (BMBH) have been synthesised and characterized by elemental analysis, molar conductivities, magnetic measurements and infrared (IR) and visible spectral studies. The IR spectra show that BCBH and BMBH behave as bidentate ligands either in the keto or enol form. (author). 24 refs., 2 tabs

  7. Synthesis, Characterization, and Biological Activity of Mn(II, Fe(II, Co(II, Ni(II, Cu(II, Zn(II, and Cd(II Complexes of N-Thiophenoyl-N′-Phenylthiocarbohydrazide

    Directory of Open Access Journals (Sweden)

    M. Yadav

    2013-01-01

    Full Text Available Mn(II, Fe(II, Co(II, Ni(II, Cu(II, Zn(II, and Cd(II complex of N-thiophenoyl -N′-phenylthiocarbohydrazide (H2 TPTH have been synthesized and characterized by elemental analysis, magnetic susceptibility measurements, infrared, NMR, electronic, and ESR spectral studies. The complexes were found to have compositions [Mn(H TPTH2], [Co(TPTH (H2O2], [Ni(TPTH (H2O2], [Cu(TPTH], [Zn(H TPTH], [Cd(H TPTH2], and [Fe(H TPTH2(EtOH]. The magnetic and electronic spectral studies suggest square planar geometry for [Cu(TPTH], tetrahedral geometry for [Zn(TPTH] and [Cd(H TPTH2], and octahedral geometry for rest of the complexes. The infrared spectral studies of the 1 : 1 deprotonated complexes suggest bonding through enolic oxygen, thiolato sulfur, and both the hydrazinic nitrogens. Thus, H2TPTH acts as a binegative tetradentate ligand. H2 TPTH and its metal complexes have been screened against several bacteria and fungi.

  8. Chemical speciation of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II binary complexes of l-methionine in 1,2-propanediol-water mixtures

    Directory of Open Access Journals (Sweden)

    M. Padma Latha

    2007-04-01

    Full Text Available Chemical speciation of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-methionine in 0.0-60 % v/v 1,2-propanediol-water mixtures maintaining an ionic strength of 0.16 M at 303 K has been studied pH metrically. The active forms of ligand are LH2+, LH and L-. The predominant species detected are ML, MLH, ML2, ML2H, ML2H2 and MLOH. Models containing different numbers of species were refined by using the computer program MINIQUAD 75. The best-fit chemical models were arrived at based on statistical parameters. The trend in variation of complex stability constants with change in the dielectric constant of the medium is explained on the basis of electrostatic and non-electrostatic forces.

  9. cobalt (ii), nickel (ii)

    African Journals Online (AJOL)

    DR. AMINU

    Department of Chemistry Bayero University, P. M. B. 3011, Kano, Nigeria. E-mail: hnuhu2000@yahoo.com. ABSTRACT. The manganese (II), cobalt (II), nickel (II) and .... water and common organic solvents, but are readily soluble in acetone. The molar conductance measurement [Table 3] of the complex compounds in.

  10. The role of cerebral hyperperfusion in postoperative neurologic dysfunction after left ventricular assist device implantation for end-stage heart failure.

    Science.gov (United States)

    Lietz, Katherine; Brown, Kevin; Ali, Syed S; Colvin-Adams, Monica; Boyle, Andrew J; Anderson, David; Weinberg, Alan D; Miller, Leslie W; Park, Soon; John, Ranjit; Lazar, Ronald M

    2009-04-01

    Cerebral hyperperfusion is a life-threatening syndrome that can occur in patients with chronically hypoperfused cerebral vasculature whose normal cerebral circulation was re-established after carotid endarterectomy or angioplasty. We sought to determine whether the abrupt restoration of perfusion to the brain after left ventricular assist device (LVAD) implantation produced similar syndromes. We studied the role of increased systemic flow after LVAD implantation on neurologic dysfunction in 69 consecutive HeartMate XVE LVAD (Thoratec, Pleasanton, Calif) recipients from October 2001 through June 2006. Neurologic dysfunction was defined as postoperative permanent or transient central change in neurologic status, including confusion, focal neurologic deficits, visual changes, seizures, or coma for more than 24 hours within 30 days after LVAD implantation. We found that 19 (27.5%) patients had neurologic dysfunction, including encephalopathy (n = 11), coma (n = 3), and other complications (n = 5). The multivariate analysis showed that an increase in cardiac index from the preoperative baseline value (relative risk, 1.33 per 25% cardiac index increase; P = .01) and a previous coronary bypass operation (relative risk, 4.53; P = .02) were the only independent predictors of neurologic dysfunction. Reduction of left ventricular assist device flow in 16 of the 19 symptomatic patients led to improvement of symptoms in 14 (87%) patients. Our findings showed that normal flow might overwhelm cerebral autoregulation in patients with severe heart failure, suggesting that cerebral hyperperfusion is possible in recipients of mechanical circulatory support with neurologic dysfunction.

  11. Mycobacterium chimaera left ventricular assist device infections.

    Science.gov (United States)

    Balsam, Leora B; Louie, Eddie; Hill, Fred; Levine, Jamie; Phillips, Michael S

    2017-06-01

    A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population. © 2017 Wiley Periodicals, Inc.

  12. Management issues during HeartWare left ventricular assist device implantation and the role of transesophageal echocardiography

    Directory of Open Access Journals (Sweden)

    Sanjay Orathi Patangi

    2013-01-01

    Full Text Available Left ventricular assist devices (LVAD are increasingly used for mechanical circulatory support of patients with severe heart failure, primarily as a bridge to heart transplantation. Transesophageal echocardiography (TEE plays a major role in the clinical decision making during insertion of the devices and in the post-operative management of these patients. The detection of structural and device-related mechanical abnormalities is critical for optimal functioning of assist device. In this review article, we describe the usefulness of TEE for optimal perioperative management of patients presenting for HeartWare LVAD insertion.

  13. Retenção do fungicida triadimenol em latossolos em razão da calagem e da fosfatagem Retention of the fungicide triadimenol in Latosol due to lime and phosphate applications

    Directory of Open Access Journals (Sweden)

    Júlio César Azevedo Nóbrega

    2005-05-01

    Full Text Available O objetivo deste trabalho foi avaliar o efeito da calagem e da fosfatagem na retenção do triadimenol em um Latossolo Vermelho-Amarelo distrófico (LVAd e em um Latossolo Vermelho distrófico (LVd em microcolunas de solo. Calagem e fosfatagem, realizadas em conjunto, reduziram a retenção do produto nas amostras do LVAd (7,7% e 8,6%, respectivamente, para a dose de 2,67 e 10,68 kg ha-1 do princípio ativo. No LVd, a calagem e fosfatagem, quando realizadas isoladamente, causaram menor retenção do produto (calagem 7,2% e 3,9%, fosfatagem 10,1% e 6,8%, respectivamente, para as doses de 2,67 e 10,68 kg ha-1 em relação às amostras controle. Apesar da quantidade do produto na solução do solo ser inferior a 1% da dose aplicada, valores mais elevados do produto foram encontrados nas amostras de solo tratadas com calcário e fosfato, isoladamente ou não, no LVAd e, isoladamente, no LVd.The objective of this work was to evaluate the effect of liming and phosphate applications on the retention of triadimenol in microcolumns of soil material of a distrophic Red-Yellow Latosol (Typic Hapludox and a distrophic Red Latosol (Typic Hapludox. Lime and phosphate applications decreased retention of triadimenol on LVAd samples (7.7% and 8.6%, respectively, for 2.67 and 10.68 kg ha-1 of the active principle. Lower retention of triadimenol was observed on LVd samples when lime and phosphate were applied separately (liming 7.2% and 3.9%, phosphate fertilization 10.1% and 6.8%, respectively, for 2.67 and 10.68 kg ha-1 of the compound. In spite of the amount of the chemical in soil solution being inferior to 1% of the dose applied, higher values of the chemical were found in the samples with lime and phosphate, singly or not in the LVAd and singly in the LVd.

  14. Metabolic volume performs better than SUVmax in the detection of left ventricular assist device driveline infection

    Energy Technology Data Exchange (ETDEWEB)

    Avramovic, Nemanja; Weckesser, Matthias; Milankovic, Danka; Vrachimis, Alexis; Wenning, Christian [University Hospital Muenster, Department of Nuclear Medicine, Muenster (Germany); Dell' Aquila, Angelo Maria; Sindermann, Juergen R. [University Hospital Muenster, Department of Cardiac Surgery, Muenster (Germany)

    2017-10-15

    A continuous-flow left ventricular assist device (LVAD) is a new and highly promising therapy in supporting end-stage heart failure patients, either bridging them to heart transplantation or as a destination therapy. Infection is one of the major complications associated with LVAD implants. {sup 18}F-FDG PET/CT has already been shown to be useful in the detection of LVAD infection. The goal of this study was to compare the diagnostic accuracy of different PET analysis techniques (visual grading versus SUVmax and metabolic volume). We retrospectively analyzed 48 patients with implanted LVAD who underwent an {sup 18}F-FDG PET/CT that were either suspected to have a driveline or device infection or inflammation of unknown origin. PET/CT was analyzed qualitatively (visual grading) and quantitatively (SUVmax and metabolic volume) and matched to the final clinical diagnosis concerning driveline infection. The final diagnosis (standard of reference) was made at the end of clinically recorded follow-up or transplantation and included microbiological cultures of the driveline exit site and/or surgical samples, and clinical signs of infection despite negative cultures as well as recurrence of symptoms. Sensitivity, specificity, positive and negative predictive value were 87.5%, 79%, 81% and 86% for visual score, 87.5%, 87.5%, 87.5% and 87.5% for SUVmax and 96%, 87.5%, 88.5%, 95.5% for metabolic volume, respectively. ROC analysis revealed an AUC of.929 for SUVmax and.969 for metabolic volume. Both SUVmax and metabolic volume had a high detection rate of patients with driveline infection (21/24 = 91.5% true positive vs. 23/26 = 88.5% true positive, respectively). However, metabolic volume detected more patients without any infection correctly (1/22 = 4.5% false negative vs. 3/24 = 12.5% false negative). {sup 18}F-FDG PET/CT is a valuable tool for the diagnosis of LVAD driveline infection with high diagnostic accuracy. Particularly the use of the metabolic volume yields very

  15. Development of a numerical pump testing framework.

    Science.gov (United States)

    Kaufmann, Tim A S; Gregory, Shaun D; Büsen, Martin R; Tansley, Geoff D; Steinseifer, Ulrich

    2014-09-01

    It has been shown that left ventricular assist devices (LVADs) increase the survival rate in end-stage heart failure patients. However, there is an ongoing demand for an increased quality of life, fewer adverse events, and more physiological devices. These challenges necessitate new approaches during the design process. In this study, computational fluid dynamics (CFD), lumped parameter (LP) modeling, mock circulatory loops (MCLs), and particle image velocimetry (PIV) are combined to develop a numerical Pump Testing Framework (nPTF) capable of analyzing local flow patterns and the systemic response of LVADs. The nPTF was created by connecting a CFD model of the aortic arch, including an LVAD outflow graft to an LP model of the circulatory system. Based on the same geometry, a three-dimensional silicone model was crafted using rapid prototyping and connected to an MCL. PIV studies of this setup were performed to validate the local flow fields (PIV) and the systemic response (MCL) of the nPTF. After validation, different outflow graft positions were compared using the nPTF. Both the numerical and the experimental setup were able to generate physiological responses by adjusting resistances and systemic compliance, with mean aortic pressures of 72.2-132.6 mm Hg for rotational speeds of 2200-3050 rpm. During LVAD support, an average flow to the distal branches (cerebral and subclavian) of 24% was found in the experiments and the nPTF. The flow fields from PIV and CFD were in good agreement. Numerical and experimental tools were combined to develop and validate the nPTF, which can be used to analyze local flow fields and the systemic response of LVADs during the design process. This allows analysis of physiological control parameters at early development stages and may, therefore, help to improve patient outcomes. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  16. Assessment of cardiac sympathetic nerve activity in children with chronic heart failure using quantitative iodine-123 metaiodobenzylguanidine imaging

    International Nuclear Information System (INIS)

    Karasawa, Kensuke; Ayusawa, Mamoru; Noto, Nobutaka; Sumitomo, Naokata; Okada, Tomoo; Harada, Kensuke

    2000-01-01

    Cardiac sympathetic nerve activity in children with chronic heart failure was examined by quantitative iodine-123 metaiodobenzylguanidine (MIBG) myocardial imaging in 33 patients aged 7.5±6.1 years (range 0-18 years), including 8 with cardiomyopathy, 15 with congenital heart disease, 3 with anthracycrine cardiotoxicity, 3 with myocarditis, 3 with primary pulmonary hypertension and 1 with Pompe's disease. Anterior planar images were obtained 15 min and 3 hr after the injection of iodine-123 MIBG. The cardiac iodine-123 MIBG uptake was assessed as the heart to upper mediastinum uptake activity ratio of the delayed image (H/M) and the cardiac percentage washout rate (%WR). The severity of chronic heart failure was class I (no medication) in 8 patients, class II (no symptom with medication) in 9, class III (symptom even with medication) in 10 and class IV (late cardiac death) in 6. H/M was 2.33±0.22 in chronic heart failure class I, 2.50±0.34 in class II, 1.95±0.61 in class III, and 1.39±0.29 in class IV (p<0.05). %WR was 24.8±12.8% in chronic heart failure class I, 23.3±10.2% in class II, 49.2±24.5% in class III, and 66.3±26.5% in class IV (p<0.05). The low H/M and high %WR were proportionate to the severity of chronic heart failure. Cardiac iodine-123 MIBG showed cardiac adrenergic neuronal dysfunction in children with severe chronic heart failure. Quantitative iodine-123 MIBG myocardial imaging is clinically useful as a predictor of therapeutic outcome and mortality in children with chronic heart failure. (author)

  17. Cr(III,Mn(II,Fe(III,Co(II,Ni(II,Cu(II and Zn(II Complexes with Diisobutyldithiocarbamato Ligand

    Directory of Open Access Journals (Sweden)

    Mohammad Tarique

    2011-01-01

    Full Text Available The synthesis of sulphur and nitrogen containing dithiocarbamato ligand derived from diisobutylamine as well as its coordination compounds with 3d series transition metals is presented. These synthesized compounds were characterized on the basis of elemental analysis, conductometric measurements and IR spectral studies. The analytical data showed the stoichiometry 1:2 and 1:3 for the compounds of the types ML2 {M=Mn(II, Co(II, Ni(II, Cu(II and Zn(II} and M'L3{M'=Cr(III and Fe(III} respectively. The conductometric measurements proved the non-electrolytic behaviour of all the compounds. The bidentate nature of dithiocarbamato moiety was confirmed on the basis of IR spectral data.

  18. The KNK II/1 fuel assembly NY-205: Compilation of the irradiation history and the fuel and fuel pin fabrication data of the INTERATOM data bank system BESEX

    International Nuclear Information System (INIS)

    Patzer, G.; Geier, F.

    1988-01-01

    The fuel assembly NY-205 has been irradiated during the first and the second core of KNK II with a total residence time of 832 equivalent full-power days. A maximum burnup of 175.000 MWd/tHM or 18.6 % was reached with a maximum steel damage of 66 dpa-NRT. For the cladding the materials 1.4970 and 1.4981 have been used in different metallurgical conditions, and for the Uranium/Plutonium mixed- oxide fuel the most important variants of the major fabrication parameters had been realized. The assembly will be brought to the Hot Cells of the KfK Karlsruhe for post-irradiation examination in February 1988, so that the knowledge of the fabrication data is of interest for the selection of fuel pins and for the evaluation of the examination results. Therefore this report compiles the fuel and fuel pin fabrication data from the INTERATOM data bank system BESEX and additionally, an overview of the irradiation history of the assembly is given [de

  19. Computer augumented modelling studies of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-glutamic acid in 1,2-propanediol–water mixtures

    Directory of Open Access Journals (Sweden)

    MAHESWARA RAO VEGI

    2008-12-01

    Full Text Available Chemical speciation of Pb(II, Cd(II, Hg(II, Co(II, Ni(II, Cu(II and Zn(II complexes of L-glutamic acid was studied at 303 K in 0–60 vol. % 1,2-propanediol–water mixtures, whereby the ionic strength was maintained at 0.16 mol dm-3. The active forms of the ligand are LH3+, LH2 and LH–. The predominant detected species were ML, ML2, MLH, ML2H and ML2H2. The trend of the variation in the stability constants with changing dielectric constant of the medium is explained based on the cation stabilizing nature of the co-solvents, specific solvent–water interactions, charge dispersion and specific interactions of the co-solvent with the solute. The effect of systematic errors in the concentrations of the substances on the stability constants is in the order alkali > > acid > ligand > metal. The bioavailability and transportation of metals are explained based on distribution diagrams and stability constants.

  20. Synthesis and characterization of heterobimetallic complexes of the type [Cu(pn2][MCl4] where M = Co(II, Ni(II, Cu(II, Zn(II, Cd(II, and Hg(II

    Directory of Open Access Journals (Sweden)

    Seema Yadav

    2016-11-01

    Full Text Available A series of new bimetallic transition metal complexes of the type [Cu(pn2] [MCl4] have been synthesized (where M = Co(II, Ni(II, Cu(II, Zn(II, Cd(II and Hg(II, pn = 1,3-diaminopropane and characterized by elemental analysis, molar conductance, TGA, IR and electronic spectra. All the compounds are 1:1 electrolyte in DMF. The Cu(II ion is square-planar while metal ions in the anionic moiety acquire their usual tetrahedral arrangement. On the basis of these studies it is concluded that anionic moiety is electrically stabilized by its cationic counterpart.

  1. Small Diameter Bomb Increment II (SDB II)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-439 Small Diameter Bomb Increment II (SDB II) As of FY 2017 President’s Budget Defense... Bomb Increment II (SDB II) DoD Component Air Force Joint Participants Department of the Navy Responsible Office References SAR Baseline (Production...Mission and Description Small Diameter Bomb Increment II (SDB II) is a joint interest United States Air Force (USAF) and Department of the Navy

  2. Synthesis and structural characterization of nickel(II), cobalt(II), Zinc(II), manganese(II), cadmium(II) and uranium(VI) complexes of α-oximinoacetoacet-o/p-anisidide thiosemicarbazone

    International Nuclear Information System (INIS)

    Patel, P.S.; Patel, M.M.; Ray, R.M.

    1993-01-01

    A few metal complexes of α-oximinoacetoacet-o/p-anisidide thiosemicarbazones (OAOATS)/(OAPATS) with Ni(II), Co(II), Zn(II), Mn(II), Hg(II), Cd(II) and UO 2 (II) have been prepared and characterized by elemental analyses, conductivity, differential scanning calorimetry study, thermogravimetric analyses and infrared and electronic spectral measurements in conjunction with magnetic susceptibility measurements at room temperature. They have also been tested for their antimicrobial activities. (author). 24 refs., 2 tabs

  3. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag

    International Nuclear Information System (INIS)

    Xue Yongjie; Hou Haobo; Zhu Shujing

    2009-01-01

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01 M NaNO 3 . In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84 mM in the single element system and 0.21 mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH 50 (the pH at which 50% adsorption occurs) was found to follow the sequence Zn > Cu > Pb > Cd in single-element systems, but Pb > Cu > Zn > Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems

  4. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag

    Energy Technology Data Exchange (ETDEWEB)

    Xue Yongjie [School of Resource and Environment Science, Wuhan University, Hubei, Wuhan (China); Wuhan Kaidi Electric Power Environmental Protection Co. Ltd., Hubei, Wuhan (China)], E-mail: xueyj@mail.whut.edu.cn; Hou Haobo; Zhu Shujing [School of Resource and Environment Science, Wuhan University, Hubei, Wuhan (China)

    2009-02-15

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01 M NaNO{sub 3}. In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84 mM in the single element system and 0.21 mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH{sub 50} (the pH at which 50% adsorption occurs) was found to follow the sequence Zn > Cu > Pb > Cd in single-element systems, but Pb > Cu > Zn > Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems.

  5. Competitive adsorption of copper(II), cadmium(II), lead(II) and zinc(II) onto basic oxygen furnace slag.

    Science.gov (United States)

    Xue, Yongjie; Hou, Haobo; Zhu, Shujing

    2009-02-15

    Polluted and contaminated water can often contain more than one heavy metal species. It is possible that the behavior of a particular metal species in a solution system will be affected by the presence of other metals. In this study, we have investigated the adsorption of Cd(II), Cu(II), Pb(II), and Zn(II) onto basic oxygen furnace slag (BOF slag) in single- and multi-element solution systems as a function of pH and concentration, in a background solution of 0.01M NaNO(3). In adsorption edge experiments, the pH was varied from 2.0 to 13.0 with total metal concentration 0.84mM in the single element system and 0.21mM each of Cd(II), Cu(II), Pb(II), and Zn(II) in the multi-element system. The value of pH(50) (the pH at which 50% adsorption occurs) was found to follow the sequence Zn>Cu>Pb>Cd in single-element systems, but Pb>Cu>Zn>Cd in the multi-element system. Adsorption isotherms at pH 6.0 in the multi-element systems showed that there is competition among various metals for adsorption sites on BOF slag. The adsorption and potentiometric titrations data for various slag-metal systems were modeled using an extended constant-capacitance surface complexation model that assumed an ion-exchange process below pH 6.5 and the formation of inner-sphere surface complexes at higher pH. Inner-sphere complexation was more dominant for the Cu(II), Pb(II) and Zn(II) systems.

  6. Preparation of Schiff s base complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II) and their spectroscopic, magnetic, thermal, and antifungal studies

    International Nuclear Information System (INIS)

    Parekh, H.M.; Patel, M.N.

    2006-01-01

    The potassium salt of salicylidene-DL-alanine (KHL), bis(benzylidene)ethylenediamine (A 1 ), thiophene-o-carboxaldene-p-toluidine (A 2 ), and its metal complexes of the formula [(M II (L)(A)(H 2 O)] (M=Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II); A = A 1 or A 2 ) are prepared. They are characterized by elemental analysis, magnetic susceptibility measurements, thermogravimetric analysis, and infrared and electronic spectral studies. The electronic spectral and magnetic moment data suggest an octahedral geometry for the complexes. All of these complexes, metal nitrates, fungicides (bavistin and emcarb), and ligands are screened for their antifungal activity against Aspergillus niger, Fusarium oxysporum, and Aspergillus flavus using a plate poison technique. The complexes show higher activity than those of the free ligands, metal nitrate, and the control (DMSO) and moderate activity against bavistin and emcarb [ru

  7. Intraoperative Transesophageal Echocardiography and Right Ventricular Failure After Left Ventricular Assist Device Implantation.

    Science.gov (United States)

    Silverton, Natalie A; Patel, Ravi; Zimmerman, Josh; Ma, Jianing; Stoddard, Greg; Selzman, Craig; Morrissey, Candice K

    2018-02-15

    To determine whether intraoperative measures of right ventricular (RV) function using transesophageal echocardiography are associated with subsequent RV failure after left ventricular assist device (LVAD) implantation. Retrospective, nonrandomized, observational study. Single tertiary-level, university-affiliated hospital. The study comprised 100 patients with systolic heart failure undergoing elective LVAD implantation. Transesophageal echocardiographic images before and after cardiopulmonary bypass were analyzed to quantify RV function using tricuspid annular plane systolic excursion (TAPSE), tricuspid annular systolic velocity (S'), fractional area change (FAC), RV global longitudinal strain, and RV free wall strain. A chart review was performed to determine which patients subsequently developed RV failure (right ventricular assist device placement or prolonged inotrope requirement ≥14 days). Nineteen patients (19%) subsequently developed RV failure. Postbypass FAC was the only measure of RV function that distinguished between the RV failure and non-RV failure groups (21.2% v 26.5%; p = 0.04). The sensitivity, specificity, and area under the curve of an abnormal RV FAC (failure after LVAD implantation were 84%, 20%, and 0.52, respectively. No other intraoperative measure of RV function was associated with subsequent RV failure. RV failure increased ventilator time, intensive care unit and hospital length of stay, and mortality. Intraoperative measures of RV function such as tricuspid annular plane systolic excursion, tricuspid annular systolic velocity, and RV strain were not associated with RV failure after LVAD implantation. Decreased postbypass FAC was significantly associated with RV failure but showed poor discrimination. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Cu(II) AND Zn(II)

    African Journals Online (AJOL)

    Preferred Customer

    SYNTHESIS OF 2,2-DIMETHYL-4-PHENYL-[1,3]-DIOXOLANE USING ZEOLITE. ENCAPSULATED Co(II), Cu(II) AND Zn(II) COMPLEXES. B.P. Nethravathi1, K. Rama Krishna Reddy2 and K.N. Mahendra1*. 1Department of Chemistry, Bangalore University, Bangalore-560001, India. 2Department of Chemistry, Government ...

  9. Spectroscopic and thermal degradation behavior of Mg(II, Ca(II, Ba(II and Sr(II complexes with paracetamol drug

    Directory of Open Access Journals (Sweden)

    Moamen S. Refat

    2017-05-01

    Full Text Available Complexes of Mg(II, Ca(II, Ba(II and Sr(II with paracetamol drug were synthesized and characterized by elemental analysis, conductivity, UV–Vis, IR, and 1H NMR spectroscopy and thermal analysis, as well as screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as paracetamol behaves as a neutral bidentate ligand coordinated to the metal ions via the lone pair of electrons of nitrogen and carbonyl-O atoms of the amide group. From the microanalytical data, the stoichiometry of the complexes reacts with Mg(II, Ca(II, Ba(II and Sr(II by molar ratios (2:1 (paracetamol:metal ion. The thermal behavior (TG/DTG of the complexes was studied. The ligand and their metal complexes were screened against both of antibacterial and fungicidal activities.

  10. Solar photocatalytic removal of Cu(II), Ni(II), Zn(II) and Pb(II): Speciation modeling of metal-citric acid complexes

    International Nuclear Information System (INIS)

    Kabra, Kavita; Chaudhary, Rubina; Sawhney, R.L.

    2008-01-01

    The present study is targeted on solar photocatalytic removal of metal ions from wastewater. Photoreductive deposition and dark adsorption of metal ions Cu(II), Ni(II), Pb(II) and Zn(II), using solar energy irradiated TiO 2 , has been investigated. Citric acid has been used as a hole scavenger. Modeling of metal species has been performed and speciation is used as a tool for discussing the photodeposition trends. Ninety-seven percent reductive deposition was obtained for copper. The deposition values of other metals were significantly low [nickel (36.4%), zinc (22.2%) and lead (41.4%)], indicating that the photocatalytic treatment process, using solar energy, was more suitable for wastewater containing Cu(II) ions. In absence of citric acid, the decreasing order deposition was Cu(II) > Ni(II) > Pb(II) > Zn(II), which proves the theoretical thermodynamic predictions about the metals

  11. Cd(II), Cu(II)

    African Journals Online (AJOL)

    user

    Depending on the way goethite was pretreated with oxalic acid, affinity for Cd(II) varied ...... Effects and mechanisms of oxalate on Cd(II) adsorption on goethite at different ... precipitation, surfactant mediation, hydrothermal and micro-emulsion.

  12. Sequestration of Cu(II), Ni(II), and Co(II) by ethyleneimine immobilized on silica

    International Nuclear Information System (INIS)

    Arakaki, Luiza N.H.; Alves, Ana Paula M.; Silva Filho, Edson C. da; Fonseca, Maria G.; Oliveira, Severino F.; Espinola, Jose Geraldo P.; Airoldi, Claudio

    2007-01-01

    Thermodynamic data on interaction of Cu(II), Ni(II), and Co(II) with silica modified with ethyleneimine are obtained by calorimetric titration. The amount of ethyleneimine anchored on silica surface was estimated to be 0.70 mmol g -1 . The enthalpies of binding Ni(II), Cu(II) and Co(II), are -3.59 ± 0.001, -4.88 ± 0.001, and -7.75 ± 0.003 kJ mol -1 , respectively

  13. 78 FR 65453 - Hazardous Materials: Corrections and Response to Administrative Appeals (HM-215K, HM-215L, HM...

    Science.gov (United States)

    2013-10-31

    ... energy storage capacity less than or equal to 10 Wh, provided in special provision of A186 of the ICAO TI... Division 4.1 (Flammable Solid) material for transportation by motor vehicle, rail car, vessel, or cargo... transportation by motor vehicle, rail car, vessel, or cargo-only aircraft, subject to the following conditions...

  14. Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Duran, Celal [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Gundogdu, Ali [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Bulut, Volkan Numan [Department of Chemistry, Giresun Faculty of Art and Science, Karadeniz Technical University, 28049 Giresun (Turkey); Soylak, Mustafa [Department of Chemistry, Faculty of Art and Science, Erciyes University, 38039 Kayseri (Turkey)]. E-mail: soylak@erciyes.edu.tr; Elci, Latif [Department of Chemistry, Faculty of Art and Science, Pamukkale University, 20020 Denizli (Turkey); Sentuerk, Hasan Basri [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Tuefekci, Mehmet [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2007-07-19

    A new method using a column packed with Amberlite XAD-2010 resin as a solid-phase extractant has been developed for the multi-element preconcentration of Mn(II), Co(II), Ni(II), Cu(II), Cd(II), and Pb(II) ions based on their complex formation with the sodium diethyldithiocarbamate (Na-DDTC) prior to flame atomic absorption spectrometric (FAAS) determinations. Metal complexes sorbed on the resin were eluted by 1 mol L{sup -1} HNO{sub 3} in acetone. Effects of the analytical conditions over the preconcentration yields of the metal ions, such as pH, quantity of Na-DDTC, eluent type, sample volume and flow rate, foreign ions etc. have been investigated. The limits of detection (LOD) of the analytes were found in the range 0.08-0.26 {mu}g L{sup -1}. The method was validated by analyzing three certified reference materials. The method has been applied for the determination of trace elements in some environmental samples.

  15. Average [O II] nebular emission associated with Mg II absorbers: dependence on Fe II absorption

    Science.gov (United States)

    Joshi, Ravi; Srianand, Raghunathan; Petitjean, Patrick; Noterdaeme, Pasquier

    2018-05-01

    We investigate the effect of Fe II equivalent width (W2600) and fibre size on the average luminosity of [O II] λλ3727, 3729 nebular emission associated with Mg II absorbers (at 0.55 ≤ z ≤ 1.3) in the composite spectra of quasars obtained with 3 and 2 arcsec fibres in the Sloan Digital Sky Survey. We confirm the presence of strong correlations between [O II] luminosity (L_{[O II]}) and equivalent width (W2796) and redshift of Mg II absorbers. However, we show L_{[O II]} and average luminosity surface density suffer from fibre size effects. More importantly, for a given fibre size, the average L_{[O II]} strongly depends on the equivalent width of Fe II absorption lines and found to be higher for Mg II absorbers with R ≡W2600/W2796 ≥ 0.5. In fact, we show the observed strong correlations of L_{[O II]} with W2796 and z of Mg II absorbers are mainly driven by such systems. Direct [O II] detections also confirm the link between L_{[O II]} and R. Therefore, one has to pay attention to the fibre losses and dependence of redshift evolution of Mg II absorbers on W2600 before using them as a luminosity unbiased probe of global star formation rate density. We show that the [O II] nebular emission detected in the stacked spectrum is not dominated by few direct detections (i.e. detections ≥3σ significant level). On an average, the systems with R ≥ 0.5 and W2796 ≥ 2 Å are more reddened, showing colour excess E(B - V) ˜ 0.02, with respect to the systems with R < 0.5 and most likely trace the high H I column density systems.

  16. Към реконструкцията на превода от Константин Преславски на Второто слово против арианите от Атанасий Александрийски

    Directory of Open Access Journals (Sweden)

    Пиринка [Pirinka] Пенкова [Penkova

    2016-10-01

    Full Text Available Towards the reconstruction of Konstantin of Preslav’s translation of Athanasius of Alexandria’s Oratio II against the Arians The author argues that the translation of Oratio II contra Arianos (MS 968 of the Pogodin Collection, National Library, St. Petersburg, attributed to Konstantin of Preslav, has been subject of two re-editions. The first Preslav translation of Orationes I–III is based on a Greek manuscript mainly belonging to the so-called x tradition with scattered features of the RSP tradition. In the first re-edition the editors did away with Konstantin of Preslav’s lexical innovations and unified the terminology. The second re-edition of Oratio II was prepared in accordance with a Greek manuscript falling strictly within the x tradition, without any RSP variants. Oratio III in MS 968 has not been re-edited by the last editor and has preserved the features of Konstantin’s original free translation. This points to a Greek protograph that must have had features of both the x and the RSP tradition. Closest to the Slavonic protograph of Oratio II and III is the Greek manuscript Atheniensis (gr. 428, tenth century. Some alternative readings are attested only in MS 968 and the Greek manuscripts Patmiacus 4 (tenth-eleventh century and Patmiacus A3 (eleventh century. It is further argued that the quotations from Athanasius of Alexandria’s Oratio II in the Slavonic translation of Euthymius Zigabenos’s Panoplia Dogmatica in manuscript HM.SMS.186 of the Hilandar Research Library (Ohio State University support the author’s hypothesis about the existence of two different translations of Oratio II: a verbatim translation in Pogodin 968 and a free translation in HM.SMS.186. Both translators must have used a Greek copy of Athanasius that corresponds to the x tradition.   O rekonstrukcji przekładu II Mowy przeciwko Arianom Atanazjusza z Aleksandrii autorstwa Konstantyna Presławskiego W artykule autorka stawia tezę, że przekład II

  17. Cardiac I123-MIBG Correlates Better than Ejection Fraction with Symptoms Severity in Systolic Heart Failure

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Sandra M.; Moscavitch, Samuel D.; Carestiato, Larissa R. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Felix, Renata M. [Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Rodrigues, Ronaldo C.; Messias, Leandro R. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Azevedo, Jader C. [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil); Nóbrega, Antonio Cláudio L.; Mesquita, Evandro Tinoco [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Mesquita, Claudio Tinoco, E-mail: ctinocom@cardiol.br [Programa de Pós-Graduação em Ciências Cardiovasculares, Hospital Universitário Antonio Pedro, Universidade Federal Fluminense, Rio de Janeiro, RJ (Brazil); Departamento de Medicina Nuclear, Hospital Pró-Cardíaco, Rio de Janeiro, RJ (Brazil)

    2013-07-15

    The association of autonomic activation, left ventricular ejection fraction (LVEF) and heart failure functional class is poorly understood. Our aim was to correlate symptom severity with cardiac sympathetic activity, through iodine-123-metaiodobenzylguanidine ({sup 123}I-MIBG) scintigraphy and with LVEF in systolic heart failure (HF) patients without previous beta-blocker treatment. Thirty-one patients with systolic HF, class I to IV of the New York Heart Association (NYHA), without previous beta-blocker treatment, were enrolled and submitted to {sup 123}I-MIBG scintigraphy and to radionuclide ventriculography for LVEF determination. The early and delayed heart/mediastinum (H/M) ratio and the washout rate (WR) were performed. According with symptom severity, patients were divided into group A, 13 patients in NYHA class I/II, and group B, 18 patients in NYHA class III/IV. Compared with group B patients, group A had a significantly higher LVEF (25% ± 12% in group B vs. 32% ± 7% in group A, p = 0.04). Group B early and delayed H/M ratios were lower than group A ratios (early H/M 1.49 ± 0.15 vs. 1.64 ± 0.14, p = 0.02; delayed H/M 1.39 ± 0.13 vs. 1.58 ± 0.16, p = 0.001, respectively). WR was significantly higher in group B (36% ± 17% vs. 30% ± 12%, p= 0.04). The variable that showed the best correlation with NYHA class was the delayed H/M ratio (r= -0.585; p=0.001), adjusted for age and sex. This study showed that cardiac {sup 123}I-MIBG correlates better than ejection fraction with symptom severity in systolic heart failure patients without previous beta-blocker treatment.

  18. Structural information on the coordination compounds formed by manganese(II), cobalt(II), nickel(II), zinc(II), cadmium(II) and mercury(II) thiocyanates with 4-cyanopyridine N-oxide from their magnetic moments, electronic and infrared spectra

    Science.gov (United States)

    Ahuja, I. S.; Yadava, C. L.; Singh, Raghuvir

    1982-05-01

    Coordination compounds formed by the interaction of 4-cyanopyridine. N-oxide (4-CPO), a potentially bidentate ligand, with manganese(II), cobalt(II), nickel(II), zinc(II), cadmium(II) and rnercury(II) thiocyanates have been prepared and characterized from their elemental analyses, magnetic susceptibilities, electronic and infrared spectral studies down to 200 cm -1 in the solid state. The compounds isolated are: Mn(4-CPO) 2(NCS) 2, Co(4-CPO) 2(NCS) 2,Ni(4-CPO) 2(NCS) 2,Zn(4-CPO) 2(NCS) 2, Cd(4-CPO)(NCS) 2 and Hg(4-CPO) 2(SCN) 2. It is shown that 4-CPO acts as a terminal N-oxide oxygen bonded monodentate ligand in all the metal(II) thiocyanate complexes studied. Tentative stereochemistries of the complexes in the solid state are discussed. The ligand field parameters 10 Dq, B, β and λ calculated for the manganese(II), cobalt(II) and nickel(II) complexes are consistent with their proposed stereochemistries.

  19. Postoperative B-Type Natriuretic Peptide as Predictor for Postoperative Outcomes in Patients Implanted With Left Ventricular Assist Devices.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Pappas, Patroklos; Tatooles, Antone

    2018-04-18

    Brain natriuretic peptide (BNP) is a cardiac neurohormone known to correlate with left ventricular (LV) dilation, decreased contractility, and increased stiffness. Consequently, BNP has been used as a prognostic tool to assess the degree of LV unloading for patients supported by continuous-flow LV assist devices (LVADs). We assessed the prognostic value of changes in BNP in the 2 weeks after LVAD implantation. This retrospective study analyzed laboratory findings and outcomes of 189 LVAD patients. Patients were separated into two groups based on whether serum BNP levels had improved from preoperative levels by postoperative day 14. Group 1 had improvement in BNP levels, whereas group 2 had no improvement or worsening in BNP. There were no significant differences between the groups in age, gender, race, body mass index, or comorbidities. Group 1 had preoperative BNP 1,125 ± 1,078.3 pg/dl and postoperative BNP 440.2 ± 267.7 pg/dl (ΔBNP = -693.09 ± 942.4 pg/dl), whereas group 2 had preoperative BNP 346.0 ± 309.1 pg/dl and postoperative BNP 631.57 ± 483.4 pg/dl (ΔBNP = 289.32 ± 329.7 pg/dl). Postoperative survival in group 2 was significantly worse than in group 1. Rates of right ventricular failure (RVF) were significantly higher in group 2 (group 1: 39%, group 2: 52.7%; p = 0.01). In most patients implanted with a LVAD, BNP improves significantly in the postoperative period as the LV is unloaded. Our results indicate that lack of improvement in postoperative BNP is associated with longer length of stay, increased rates of RVF, and is an independent risk factor for reduced postoperative survival.

  20. Preoperative atrial fibrillation increases risk of thromboembolic events after left ventricular assist device implantation.

    Science.gov (United States)

    Stulak, John M; Deo, Salil; Schirger, John; Aaronson, Keith D; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Pagani, Francis D

    2013-12-01

    Because no series has specifically analyzed the impact of preoperative atrial fibrillation (AF) on patients already at higher risk of thromboembolism after implantation of a left ventricular assist device (LVAD), we review our experience with these patients. Between July 2003 and September 2011, 389 patients (308 male) underwent implantation of a continuous flow LVAD at University of Michigan Hospital and Mayo Clinic. Median age at implant was 60 years (range, 18 to 79 years). Preoperative AF was present in 120 patients (31%). Outcomes were analyzed for the association of preoperative AF and postoperative thromboembolic (TE) events defined as stroke, transient ischemic attack, hemolysis, or pump thrombosis. Thromboembolic events occurring within the first 30 days were not counted. One hundred thirty-eight TEs events occurred in 97/389 patients (25%) for an event rate of 0.31 TE events/patient-years of support. Freedom from a TE event in patients with preoperative AF was 62% at 1 year and 46% at 2 years compared with 79% and 72% at 1 and 2 years, respectively, in patients without preoperative AF (p < 0.001). Median survival was 10 months (maximum 7.2 years, total 439 patient-years). Preoperative AF did not decrease late survival at 1 and 2 years after LVAD implant (preop AF: 85% and 70% versus no preop AF: 82% and 70%, respectively; p = 0.55). Patients with preoperative AF have a lower freedom from TE events after LVAD implant. While overall late survival was not significantly reduced in these patients, refinement in anticoagulation strategies after VAD implant may be required. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Macrocyclic receptor showing extremely high Sr(II)/Ca(II) and Pb(II)/Ca(II) selectivities with potential application in chelation treatment of metal intoxication.

    Science.gov (United States)

    Ferreirós-Martínez, Raquel; Esteban-Gómez, David; Tóth, Éva; de Blas, Andrés; Platas-Iglesias, Carlos; Rodríguez-Blas, Teresa

    2011-04-18

    Herein we report a detailed investigation of the complexation properties of the macrocyclic decadentate receptor N,N'-Bis[(6-carboxy-2-pyridil)methyl]-4,13-diaza-18-crown-6 (H(2)bp18c6) toward different divalent metal ions [Zn(II), Cd(II), Pb(II), Sr(II), and Ca(II)] in aqueous solution. We have found that this ligand is especially suited for the complexation of large metal ions such as Sr(II) and Pb(II), which results in very high Pb(II)/Ca(II) and Pb(II)/Zn(II) selectivities (in fact, higher than those found for ligands widely used for the treatment of lead poisoning such as ethylenediaminetetraacetic acid (edta)), as well as in the highest Sr(II)/Ca(II) selectivity reported so far. These results have been rationalized on the basis of the structure of the complexes. X-ray crystal diffraction, (1)H and (13)C NMR spectroscopy, as well as theoretical calculations at the density functional theory (B3LYP) level have been performed. Our results indicate that for large metal ions such as Pb(II) and Sr(II) the most stable conformation is Δ(δλδ)(δλδ), while for Ca(II) our calculations predict the Δ(λδλ)(λδλ) form being the most stable one. The selectivity that bp18c6(2-) shows for Sr(II) over Ca(II) can be attributed to a better fit between the large Sr(II) ions and the relatively large crown fragment of the ligand. The X-ray crystal structure of the Pb(II) complex shows that the Δ(δλδ)(δλδ) conformation observed in solution is also maintained in the solid state. The Pb(II) ion is endocyclically coordinated, being directly bound to the 10 donor atoms of the ligand. The bond distances to the donor atoms of the pendant arms (2.55-2.60 Å) are substantially shorter than those between the metal ion and the donor atoms of the crown moiety (2.92-3.04 Å). This is a typical situation observed for the so-called hemidirected compounds, in which the Pb(II) lone pair is stereochemically active. The X-ray structures of the Zn(II) and Cd(II) complexes show that

  2. Leptin Levels Are Higher in Whole Compared to Skim Human Milk, Supporting a Cellular Contribution.

    Science.gov (United States)

    Kugananthan, Sambavi; Lai, Ching Tat; Gridneva, Zoya; Mark, Peter J; Geddes, Donna T; Kakulas, Foteini

    2016-11-08

    Human milk (HM) contains a plethora of metabolic hormones, including leptin, which is thought to participate in the regulation of the appetite of the developing infant. Leptin in HM is derived from a combination of de novo mammary synthesis and transfer from the maternal serum. Moreover, leptin is partially lipophilic and is also present in HM cells. However, leptin has predominately been measured in skim HM, which contains neither fat nor cells. We optimised an enzyme-linked immunosorbent assay for leptin measurement in both whole and skim HM and compared leptin levels between both HM preparations collected from 61 lactating mothers. Whole HM leptin ranged from 0.2 to 1.47 ng/mL, whilst skim HM leptin ranged from 0.19 to 0.9 ng/mL. Whole HM contained, on average, 0.24 ± 0.01 ng/mL more leptin than skim HM ( p < 0.0001, n = 287). No association was found between whole HM leptin and fat content ( p = 0.17, n = 287), supporting a cellular contribution to HM leptin. No difference was found between pre- and post-feed samples (whole HM: p = 0.29, skim HM: p = 0.89). These findings highlight the importance of optimising HM leptin measurement and assaying it in whole HM to accurately examine the amount of leptin received by the infant during breastfeeding.

  3. Leptin Levels Are Higher in Whole Compared to Skim Human Milk, Supporting a Cellular Contribution

    Directory of Open Access Journals (Sweden)

    Sambavi Kugananthan

    2016-11-01

    Full Text Available Human milk (HM contains a plethora of metabolic hormones, including leptin, which is thought to participate in the regulation of the appetite of the developing infant. Leptin in HM is derived from a combination of de novo mammary synthesis and transfer from the maternal serum. Moreover, leptin is partially lipophilic and is also present in HM cells. However, leptin has predominately been measured in skim HM, which contains neither fat nor cells. We optimised an enzyme-linked immunosorbent assay for leptin measurement in both whole and skim HM and compared leptin levels between both HM preparations collected from 61 lactating mothers. Whole HM leptin ranged from 0.2 to 1.47 ng/mL, whilst skim HM leptin ranged from 0.19 to 0.9 ng/mL. Whole HM contained, on average, 0.24 ± 0.01 ng/mL more leptin than skim HM (p < 0.0001, n = 287. No association was found between whole HM leptin and fat content (p = 0.17, n = 287, supporting a cellular contribution to HM leptin. No difference was found between pre- and post-feed samples (whole HM: p = 0.29, skim HM: p = 0.89. These findings highlight the importance of optimising HM leptin measurement and assaying it in whole HM to accurately examine the amount of leptin received by the infant during breastfeeding.

  4. Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device

    Science.gov (United States)

    Smith, P. Alex; Cohn, William; Metcalfe, Ralph

    2017-11-01

    A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.

  5. Bridge to recovery in two cases of dilated cardiomyopathy after long-term mechanical circulatory support.

    Science.gov (United States)

    Pacholewicz, Jerzy; Zakliczyński, Michał; Kowalik, Violetta; Nadziakiewicz, Paweł; Kowalski, Oskar; Kalarus, Zbigniew; Zembala, Marian

    2014-06-01

    Ventricular assist devices (VADs) have become an established therapeutic option for patients with end-stage heart failure. Achieving the potential for recovery of native heart function using VADs is an established form of treatment in a selected group of patients with HF. We report two cases of VAD patients with different types of pump used for mechanical circulatory support, a continuous flow pump (Heart-Ware(®)) and a pulsatile pump (POLVAD MEV(®)), which allow regeneration of the native heart. Patients were qualified as INTERMACS level 3-4 for elective implantation of an LVAD. Implantations were performed without complications. The postoperative course was uncomplicated. In the HeartWare patient the follow-up was complicated by episodes of epistaxis and recurrent GIB as well as driveline infection. The follow-up of the POLVAD MEV patient was uneventful. Recurrent GIB forced us to withdraw aspirin and warfarin therapy and maintain only clopidogrel in the HeartWare patient.. In mid-February 2013 the patient was admitted due to dysfunction of the centrifugal pump with a continuous low-flow alarm and increase power consumption. Under close monitoring of the patient a decision was made to stop the pump immediately and evaluate cardiac function. The serial echocardiography studies showed significant improvement in LVEF up to 45% and no significant valvular pathology. In February 2013 LVAD explant was performed by left thoracotomy without complications. At six-month follow-up the patient was in a good clinical condition, in NYHA class I/II, and on pharmacological treatment.

  6. Solid Phase Extraction of Trace Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II) Ions in Beverages on Functionalized Polymer Microspheres Prior to Flame Atomic Absorption Spectrometric Determinations.

    Science.gov (United States)

    Berber, Hale; Alpdogan, Güzin

    2017-01-01

    In this study, poly(glycidyl methacrylate-methyl methacrylate-divinylbenzene) was synthesized in the form of microspheres, and then functionalized by 2-aminobenzothiazole ligand. The sorption properties of these functionalized microspheres were investigated for separation, preconcentration and determination of Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II) ions using flame atomic absorption spectrometry. The optimum pH values for quantitative sorption were 2 - 4, 5 - 8, 6 - 8, 4 - 6, 2 - 6 and 2 - 3 for Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II), respectively, and also the highest sorption capacity of the functionalized microspheres was found to be for Cu(II) with the value of 1.87 mmol g -1 . The detection limits (3σ; N = 6) obtained for the studied metals in the optimal conditions were observed in the range of 0.26 - 2.20 μg L -1 . The proposed method was successfully applied to different beverage samples for the determination of Al(III), Fe(II), Co(II), Cu(II), Cd(II) and Pb(II) ions, with the relative standard deviation of <3.7%.

  7. Thermal Degradation of Complexes Derived from Cu (II) Groundnut (Arachis hypogaea) and Sesame (Sesamum indicum) Soaps

    Science.gov (United States)

    Joram, Anju; Sharma, Rashmi; Sharma, Arun kumar

    2018-05-01

    The complexes have been synthesized from Cu (II) soaps of groundnut (Arachis hypogaea) and sesame (Sesamum indicum) oils, with ligand containing nitrogen and sulfur atoms like 2-amino-6-methyl benzothiazole. The complexes were greenish brown in color. In order to study TGA, first characterized them by elemental analysis, and spectroscopic technique such as IR, NMR and ESR. From the analytical data, the stoichiometry's of the complexes have been observed to be 1:1 (metal:ligand). These complexes have been thermally analyzed using TGA techniques to determine their energy of activation. These complexes show three step thermal degradation corresponding to fatty acid components of the edible oils and each complex has three decomposition steps in the range of 439-738 K. Various equations like Coats-Redfern (CR), Horowitz-Metzger (HM) and Broido equations (BE) were applied to evaluate the energy of activation. The values of energy of activation are observed to be in the following order for both copper groundnut benzothiazole (CGB) and copper sesame benzothiazole (CSeB) complexes: CGB > CSeB. CGB is observed to be more stable than CSeB due to its higher activation energy. The above studies would provide significant information regarding the applications of synthesized agrochemicals and their safe removal through parameters obtained in degradation curves and its relation with energy.

  8. Long-term activation upon brief exposure to xanomleline is unique to M1 and M4 subtypes of muscarinic acetylcholine receptors.

    Directory of Open Access Journals (Sweden)

    Eva Šantrůčková

    Full Text Available Xanomeline is an agonist endowed with functional preference for M1/M4 muscarinic acetylcholine receptors. It also exhibits both reversible and wash-resistant binding to and activation of these receptors. So far the mechanisms of xanomeline selectivity remain unknown. To address this question we employed microfluorometric measurements of intracellular calcium levels and radioligand binding to investigate differences in the short- and long-term effects of xanomeline among muscarinic receptors expressed individually in Chinese hamster ovary cells. 1/One-min exposure of cells to xanomeline markedly increased intracellular calcium at hM1 and hM4, and to a lesser extent at hM2 and hM3 muscarinic receptors for more than 1 hour. 2/Unlike the classic agonists carbachol, oxotremorine, and pilocarpine 10-min exposure to xanomeline did not cause internalization of any receptor subtype. 3/Wash-resistant xanomeline selectively prevented further increase in intracellular calcium by carbachol at hM1 and hM4 receptors. 4/After transient activation xanomeline behaved as a long-term antagonist at hM5 receptors. 5/The antagonist N-methylscopolamine (NMS reversibly blocked activation of hM1 through hM4 receptors by xanomeline. 6/NMS prevented formation of xanomeline wash-resistant binding and activation at hM2 and hM4 receptors and slowed them at hM1, hM3 and hM5 receptors. Our results show commonalities of xanomeline reversible and wash-resistant binding and short-time activation among the five muscarinic receptor subtypes. However long-term receptor activation takes place in full only at hM1 and hM4 receptors. Moreover xanomeline displays higher efficacy at hM1 and hM4 receptors in primary phasic intracellular calcium release. These findings suggest the existence of particular activation mechanisms specific to these two receptors.

  9. Synthesis, characterization and thermal studies of nickel (II), copper (II), zinc (II) and cadmium (II) complexes with some mixed ligands

    International Nuclear Information System (INIS)

    Mitra, Samiran; Kundu, Parimal; Singh, Rajkumar Bhubon

    1998-01-01

    Dichloro-(DCA) and trichloroacetate(TCA) -cyclic ligand morpholine (Morph)/thiomorpholine (Tmorph)/methylmorpholine (Mmorph)/dimethyl-piperazine (DMP) complexes of nickel (II), copper (II), zinc (II) and cadmium (II) with the compositions [Ni(tmorph) 2 (DCA) 2 ], [Ni(tmorph) 2 (TCA) 2 ].2H 2 O, [Cu(DMP) 2 (TCA) 2 ],[ML 2 X 2 ].nH 2 O where M=Zn II or Cd II , L=Morph, DMP or tmorph and X=DCA or TCA and n=O except in case of [Cd (Morph) 2 (TCA) 2 ] where n=1 have been synthesised. Some intermediate complexes have been isolated by temperature arrest technique (pyrolysis) and characterised. Configurational and conformational changes have been studied by elemental analyses, IR and electronic spectra, magnetic moment data (in the case of Ni(II) and Cu(II) complexes) and thermal analysis. E a * , ΔH, and ΔS for the decomposition reaction of these complexes are evaluated and the stability of the complexes with respect to activation energy has also been compared. The linear correlation has been found between E a * and ΔS for the decomposition of the complexes. (author)

  10. Competition from Cu(II), Zn(II) and Cd(II) in Pb(II) binding to Suwannee River Fulvic Acid

    NARCIS (Netherlands)

    Chakraborty, P.; Chakrabarti, C.L.

    2008-01-01

    This is a study of trace metal competition in the complexation of Pb(II) by well-characterized humic substances, namely Suwannee River Fulvic Acid (SRFA) in model solutions. It was found that Cu(II) seems to compete with Pb(II) for strong binding sites of SRFA when present at the same concentration

  11. Synthesis, investigation and spectroscopic characterization of piroxicam ternary complexes of Fe(II), Fe(III), Co(II), Ni(II), Cu(II) and Zn(II) with glycine and DL-phenylalanine

    Science.gov (United States)

    Mohamed, Gehad G.; El-Gamel, Nadia E. A.

    2004-11-01

    The ternary piroxicam (Pir; 4-hydroxy-2-methyl- N-(2-pyridyl)-2H-1,2-benzothiazine-3-carboxamide 1,1-dioxide) complexes of Fe(II), Fe(III), Co(II), Ni(II), Cu(II) and Zn(II) with various amino acids (AA) such as glycine (Gly) or DL-phenylalanine (PhA) were prepared and characterized by elemental analyses, molar conductance, IR, UV-Vis, magnetic moment, diffuse reflectance and X-ray powder diffraction. The UV-Vis spectra of Pir and the effect of metal chelation on the different interligand transitions are discussed in detailed manner. IR and UV-Vis spectra confirm that Pir behaves as a neutral bidentate ligand coordinated to the metal ions via the pyridine- N and carbonyl group of the amide moiety. Gly molecule acted as a uninegatively monodentate ligand and coordinate to the metal ions through its carboxylic group, in addition PhA acted as a uninegatively bidentate ligand and coordinate to the metal ions through its carboxylic and amino groups. All the chelates have octahedral geometrical structures while Cu(II)- and Zn(II)-ternary chelates with PhA have square planar geometrical structures. The molar conductance data reveal that most of these chelates are non electrolytes, while Fe(III)-Pir-Gly, Co(II)-, Ni(II)-, Cu(II)- and Zn(II)-Pir-PhA cheletes were 1:1 electrolytes. X-ray powder diffraction is used as a new tool to estimate the crystallinity of chelates as well as to elucidate their geometrical structures.

  12. Coordination compounds of cobalt(II), nickel(II), copper(II), and zinc(II) with pantothenic acid

    Energy Technology Data Exchange (ETDEWEB)

    Shabilalov, A.A.; Yunuskhodzhaev, A.N.; Khodzhaev, O.F.; Azizov, M.A.

    1986-11-01

    The compounds Ni(PANA - H)/sub 2/ x 4H/sub 2/O (PANA stands for pantothenic acid, and - H indicates a deprotonated ligand), Cu(PANA - H)/sub 2/ x 2H/sub 2/O, Zn(PANA - H)/sub 2/ x H/sub 2/O, Co(PANA - H)Cl x H/sub 2/O, and Ni(PANA - H)Cl x 3H/sub 2/O have been synthesized on the basis of pantothenic acid and Co(II), Ni(II), Cu(II), and Zn(II) salts in aqueous media. The compounds have been identified by elemental and x-ray diffraction analysis. Some physicochemical properties (solubility, melting point, molar conductivity) of the compounds obtained have been studied. The structure of the compounds isolated has been established on the basis of an analysis of their IR, ESR, and electronic spectra, as well as derivatograms.

  13. Dynamics of arbuscular mycorrhizal symbiosis in heavy metal phytoremediation: Meta-analytical and conceptual perspectives

    International Nuclear Information System (INIS)

    Audet, Patrick; Charest, Christiane

    2007-01-01

    To estimate dynamics of arbuscular mycorrhizal (AM) symbiosis in heavy metal (HM) phytoremediation, we conducted a literature survey and correlated HM uptake and relative plant growth parameters from published data. After estimating AM feedback responses for these parameters at low and high soil-HM concentration intervals, we determined that the roles of AM symbiosis are characterized by (1) an increased HM phytoextraction via mycorrhizospheric 'Enhanced Uptake' at low soil-HM concentrations, and (2) a reduced HM bioavailability via AM fungal 'Metal-Binding' processes at high soil-HM levels, hence resulting in increased plant biomass and enhanced plant tolerance through HM stress-avoidance. We present two conceptual models which illustrate the important compromise between plant growth, plant HM uptake and HM tolerance, and further emphasize the importance of AM symbiosis in buffering the soil environment for plants under such stress conditions. - This meta-analysis has revealed a transition role of the AM symbiosis in phytoremediation shifting from 'Enhanced Uptake' to 'Metal-Binding' beyond critical soil-HM levels

  14. Spectroscopic and thermal degradation behavior of Mg(II), Ca(II), Ba(II) and Sr(II) complexes with paracetamol drug

    OpenAIRE

    Moamen S. Refat; Gehad G. Mohamed; Mohamed Y. El-Sayed; Hamada M.A. Killa; Hammad Fetooh

    2017-01-01

    Complexes of Mg(II), Ca(II), Ba(II) and Sr(II) with paracetamol drug were synthesized and characterized by elemental analysis, conductivity, UV–Vis, IR, and 1H NMR spectroscopy and thermal analysis, as well as screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as paracetamol behaves as a neutral bidentate ligand coordinated to the metal ions via the lone pair of electrons of nitrogen and carbonyl-O atoms of the amide group. From the microanalytical dat...

  15. Optimization of simultaneous electrochemical determination of Cd(II), Pb(II), Cu(II) and Hg(II) at carbon nanotube-modified graphite electrodes.

    Science.gov (United States)

    Pikna, L'ubomír; Heželová, Mária; Kováčová, Zuzana

    2015-01-01

    The health of the environment is worsening every day. Monitoring of potentially toxic elements and remediation of environmental pollution are necessary. Therefore, the research and development of simple, inexpensive, portable and effective sensors is important. Electrochemistry is a useful component of the field of environment monitoring. The present study focuses on evaluating and comparing three types of electrodes (PIGE, PIGE/MWCNT/HNO3 and PIGE/MWCNT/EDTA/HNO3) employed for the simultaneous electrochemical determination of four potentially toxic elements: Cd(II), Pb(II), Cu(II) and Hg(II). Cyclic voltammograms were measured in an acetate buffer. The LOD, LOQ, the standard and relative precisions of the method and a prediction intervals were calculated (according to the technical procedure DIN 32 645) for the three electrodes and for each measured element. The LOD for PIGE/CNT/HNO3 (the electrode with narrowest calculated prediction intervals) was 2.98 × 10(-7) mol L(-1) for Cd(II), 4.83 × 10(-7) mol L(-1) for Pb(II), 3.81 × 10(-7) mol L(-1) for Cu(II), 6.79 × 10(-7) mol L(-1) for Hg(II). One of the benefits of this study was the determination of the amount of Hg(II) in the mixture of other elements.

  16. Synthesis, spectral characterization thermal stability, antimicrobial studies and biodegradation of starch–thiourea based biodegradable polymeric ligand and its coordination complexes with [Mn(II), Co(II), Ni(II), Cu(II), and Zn(II)] metals

    OpenAIRE

    Nahid Nishat; Ashraf Malik

    2016-01-01

    A biodegradable polymer was synthesized by the modification reaction of polymeric starch with thiourea which is further modified by transition metals, Mn(II), Co(II), Ni(II), Cu(II) and Zn(II). All the polymeric compounds were characterized by (FT-IR) spectroscopy, 1H NMR spectroscopy, 13C NMR spectroscopy, UV–visible spectra, magnetic moment measurements, thermogravimetric analysis (TGA) and antibacterial activities. Polymer complexes of Mn(II), Co(II) and Ni(II) show octahedral geometry, wh...

  17. Extraction studies of Cd(II), Cu(II), Mn(II), Ni(II) and Zn(II) using N, N', N, N' -Bis((2-hydroxy-3,5-di-tert-butylbenzyl) (2-pyridylmethyl)) -ethylenediamine as a novel ligand

    International Nuclear Information System (INIS)

    Laus, R.; Anjos, A.D.; Naves, A.

    2008-01-01

    In the present study, the use of N,N',N,N'-bis((2-hydroxy-3,5-di-tert-butylbenzyl) (2- pyridylmethyl))-ethylenediamine (H2L) as ligand was evaluated in the liquid-liquid (water- chloroform) extraction of Cd(II), Cu(II), Mn(II), Ni(II) and Zn(II). Experiments were carried out to determine the pH for maximum extraction for each metal ion by ligand, maximum extraction capacity, extraction kinetics and extraction selectivity. The results revealed that the extraction of metal ions is dependent on the pH: maximum extraction maximum was obtained in the pH range of 4.5 - 6.0 for Cu(II) and 8.0 - 9.0 for Zn(II). Cd(II) and Mn(II) were best extracted at pH 9.0 and Ni(II) at 10.0. The ligand H2L was effective for the extraction of Cd(II), Cu(II) and Zn(II) (extraction efficient, %E equal 100%), whereas %E of 76% and 23.5% were observed for Mn(II) and Ni(II), respectively. The ligand presented high selectivity for the extraction of Cu(II) at pH 4.0. (author)

  18. Preparation and Spectral Properties of Mixed-Ligand Complexes of VO(IV, Ni(II, Zn(II, Pd(II, Cd(II and Pb(II with Dimethylglyoxime and N-acetylglycine

    Directory of Open Access Journals (Sweden)

    Shayma A. Shaker

    2010-01-01

    Full Text Available A number of mixed-ligand complexes of the general formula [M(D(G] where D=dimethylglyoximato monoanion, G=N-acetylglycinato and M=VO(IV, Ni(II, Zn(II, Pd(II, Cd(II and Pb(II were prepared. Each complex was characterized by elemental analysis, determination of metal, infrared spectra, electronic spectra, (1H and 13C NMR spectra, conductivity and magnetic moments. All these complexes were not soluble in some of the organic solvent but highly soluble in dimethylformamide. The conductivity data showed the non-electrolytic nature of the complexes. The electronic spectra exhibited absorption bands in the visible region caused by the d-d electronic transition such as VO(IV, Ni(II and Pd(II. The IR and (1H, 13C NMR spectra which have indicate that the dimethylglyoxime was coordinated with the metal ions through the N and O atoms of the oxime group and N-acetylglycine was coordinated with metal ions through the N atom and terminal carboxyl oxygen atom.

  19. Synthesis and characterization of polychelates of Cu(II), Ni(II), Co(II), Mn(II), Zn(II), oxovanadium(IV) and dioxouranium(VI) with 2,4-dihydroxybenzaldehyde-urea-formaldehyde polymer

    International Nuclear Information System (INIS)

    Patel, G.C.; Pancholi, H.B.; Patel, M.M.

    1991-01-01

    Polychelates of Cu(II), Ni(II), Co(II), Mn(II), Zn(II), oxovandium(IV) and dioxouranium(VI) with 2,4-dihydroxybenzaldehyde (2,4-DB)-urea(U)-formaldehyde(F) polymer (2,4-DBUF) have been prepared. Elemental analyses of the polychelates indicate a metal:ligand ratio of 1:2. The structures of the polychelates have been assigned on the basis of their elemental analyses, IR, reflectance spectra, magnetic moment, thermal data and their electrical conductivity behaviour. (author). 1 tab., 18 refs

  20. Ni (II) and Cu(II) complexes of

    African Journals Online (AJOL)

    ADOWIE PERE

    ABSTRACT: The objective of this study is to investigate the antimicrobial activity of novel. Schiff base metal complexes. The resistance of micro-organisms to classical antimicrobial compounds poses a challenge to effective management and treatment of some diseases. In line with this, copper (II), nickel (II) and cobalt (II) ...

  1. Synthesis and characterization of chromium(III), manganese(II), iron(III), cobalt(II), nickel(II), copper(II), cadmium(II) and dioxouranium(VI) complexes of 4(2-pyridyl)-1-(2,4-dihydroxybenzaldehyde)-3-thiosemicarbazone

    International Nuclear Information System (INIS)

    Abu El-Reash, G.M.; Ibrahim, M.M.; Kenawy; El-Ayaan, Usama; Khattab, M.A.

    1994-01-01

    A few complexes of Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and dioxouranium(VI) with 4(2-pyridyl)-1-(2,4-dihydroxybenzaldehyde)-3-thiosemicarbazone have been synthesised and characterized on the basis of elemental analysis, IR, electronic NMR, and magnetic moment data. An octahedral structure is proposed for the Cr(III), Fe(III), Co(II) and Ni(H 3 PBT) 2 Cl 2 .2H 2 O complexes; a tetrahedral structure for the Mn(II) and Ni 2 (PBT)OAc.H 2 0 complexes and a square planar structure for the Cu(II) complexes. The antimicrobial and antifungal activities of H 3 PBT and of its metal(II) complexes are investigated. The results reveal that H 3 PBT exhibits greater antimicrobial activities than its complexes. (author). 34 refs., 4 figs., 2 tabs

  2. Copper (II)

    African Journals Online (AJOL)

    CLEMENT O BEWAJI

    Valine (2 - amino - 3 – methylbutanoic acid), is a chemical compound containing .... Stability constant (Kf). Gibb's free energy. ) (. 1. −. ∆. Mol. JG. [CuL2(H2O)2] ... synthesis and characterization of Co(ii), Ni(ii), Cu (II), and Zn(ii) complexes with ...

  3. [Analytic study of dot blotting for the detection of anti-Jo-1, anti-M2, anti-ribosomes and anti-LKM].

    Science.gov (United States)

    Huguet, S; Sghiri, R; Ballot, E; Johanet, C

    2004-01-01

    The Cyto-Dot 4 HM043 kit commercialised by BMD, has replaced the Cyto-Dot HM010 kit that allowed three auto-antibodies detection (anti-Jo-1, anti-M2 and anti-ribosomal protein). Detection of anti-LKM1 auto-antibody was added. These four auto-antibodies have in common only the intracytoplasmic localisation of their respective antigen. The aim of our study was to evaluate this new kit using 104 sera and to compare our results with reference techniques (indirect immunofluorescence IF for anti-M2, anti-ribosomal protein and anti-LKM1, double immunodiffusion ID for anti-Jo-1 and anti-LKM1, western blotting WB for anti-M2) and with Cyto-Dot HM010. The one hundred and four sera were divided into five groups: Group I (n = 12) with anti-Jo-1 detected by ID; Group II (n = 28) with 26 anti-M2 positive by IF and WB, 2 anti-M2 positive only by WB; Group III (n = 10) with anti-ribosomal protein detected by IF 5 of which precipitated by ID; Group IV (n = 32) with anti-LKM1 by IF and ID divided into 18 AIH2 and 14 HCV; Group V (n = 22) consisting of 14 healthy individuals and 8 patients with hypergammaglobulinemia. Results of this study are similar to those of Cyto-Dot HM010 for the three auto-antibodies already in use. Cyto-Dot 4 is a very good anti-LKM1 confirmation method as it is ID. Copyright John Libbey Eurotext 2003.

  4. Efficacy and Safety of Peroral Endoscopic Myotomy for Treatment of Achalasia After Failed Heller Myotomy.

    Science.gov (United States)

    Ngamruengphong, Saowanee; Inoue, Haruhiro; Ujiki, Michael B; Patel, Lava Y; Bapaye, Amol; Desai, Pankaj N; Dorwat, Shivangi; Nakamura, Jun; Hata, Yoshitaka; Balassone, Valerio; Onimaru, Manabu; Ponchon, Thierry; Pioche, Mathieu; Roman, Sabine; Rivory, Jérôme; Mion, François; Garros, Aurélien; Draganov, Peter V; Perbtani, Yaseen; Abbas, Ali; Pannu, Davinderbir; Yang, Dennis; Perretta, Silvana; Romanelli, John; Desilets, David; Hayee, Bu; Haji, Amyn; Hajiyeva, Gulara; Ismail, Amr; Chen, Yen-I; Bukhari, Majidah; Haito-Chavez, Yamile; Kumbhari, Vivek; Saxena, Payal; Talbot, Michael; Chiu, Philip Wai-Yan; Yip, Hon-Chi; Wong, Vivien Wai-Yin; Hernaez, Ruben; Maselli, Roberta; Repici, Alessandro; Khashab, Mouen A

    2017-10-01

    In patients with persistent symptoms after Heller myotomy (HM), treatment options include repeat HM, pneumatic dilation, or peroral endoscopic myotomy (POEM). We evaluated the efficacy and safety of POEM in patients with achalasia with prior HM vs without prior HM. We conducted a retrospective cohort study of 180 patients with achalasia who underwent POEM at 13 tertiary centers worldwide, from December 2009 through September 2015. Patients were divided into 2 groups: those with prior HM (HM group, exposure; n = 90) and those without prior HM (non-HM group; n = 90). Clinical response was defined by a decrease in Eckardt scores to 3 or less. Adverse events were graded according to criteria set by the American Society for Gastrointestinal Endoscopy. Technical success, clinical success, and rates of adverse events were compared between groups. Patients were followed up for a median of 8.5 months. POEM was technically successful in 98% of patients in the HM group and in 100% of patients in the non-HM group (P = .49). A significantly lower proportion of patients in the HM group had a clinical response to POEM (81%) than in the non-HM group (94%; P = .01). There were no significant differences in rates of adverse events between the groups (8% in the HM group vs 13% in the non-HM group; P = .23). Symptomatic reflux and reflux esophagitis after POEM were comparable between groups. POEM is safe and effective for patients with achalasia who were not treated successfully by prior HM. Although the rate of clinical success in patients with prior HM is lower than in those without prior HM, the safety profile of POEM is comparable between groups. Copyright © 2017 AGA Institute. Published by Elsevier Inc. All rights reserved.

  5. Synthesis and Spectral Investigations of Manganese(II, Cobalt(II, Nickel(II, Copper(II and Zinc(II Complexes of New Polydentate Ligands Containing a 1,8-Naphthyridine Moiety

    Directory of Open Access Journals (Sweden)

    Sunkari Jyothi

    2006-12-01

    Full Text Available 2-(o-Hydroxyphenyl-1,8-naphthyridine (HN, 2-(4-hydroxy-6-methylpyran-2-one-3-yl-1,8-naphthyridine (HMPN and 2-(benzimidazol-2-yl-1,8-naphthyridine(BN react with acetates of Mn(II, Co(II, Ni(II, Cu(II and Zn(II to yield metal ioncomplexes of definite composition. These compounds were characterized by elementalanalyses, molar conductivity, magnetic susceptibility measurements, thermal studies, IR,UV-visible, NMR and mass spectral investigations. The complexes are found to have theformulae [M(HN2(H2O2], [M(HMPN2(H2O2] and [M(BN2(OAc2], respectively.

  6. Short-term mechanical circulatory support as a bridge to durable left ventricular assist device implantation in refractory cardiogenic shock: a systematic review and meta-analysis.

    Science.gov (United States)

    den Uil, Corstiaan A; Akin, Sakir; Jewbali, Lucia S; Dos Reis Miranda, Dinis; Brugts, Jasper J; Constantinescu, Alina A; Kappetein, Arie Pieter; Caliskan, Kadir

    2017-07-01

    Short-term mechanical circulatory support (MCS) is increasingly used as a bridge to decision in patients with refractory cardiogenic shock. Subsequently, these patients might be bridged to durable MCS either as a bridge to candidacy/transplantation, or as destination therapy. The aim of this study was to review support duration and clinical outcome of short-term MCS in cardiogenic shock, and to analyse application of this technology as a bridge to long-term cardiac support (left ventricular assist device, LVAD) from 2006 till June 2016. Using Cochrane Register of Trials, Embase and Medline, a systematic review was performed on patients with cardiogenic shock from acute myocardial infarction, end-stage cardiomyopathy, or acute myocarditis, receiving short-term MCS. Studies on periprocedural, post-cardiotomy and cardiopulmonary resuscitation support were excluded. Thirty-nine studies, mainly registries of heterogeneous patient populations (n = 4151 patients), were identified. Depending on the device used (intra-aortic balloon pump, TandemHeart, Impella 2.5, Impella 5.0, CentriMag and peripheral veno-arterial extracorporeal membrane oxygenation), mean support duration was (range) 1.6-25 days and the mean proportion of short-term MCS patients discharged was (range) 45-66%. The mean proportion of bridge to durable LVAD was (range) 3-30%. Bridge to durable LVAD was most frequently performed in patients with end-stage cardiomyopathy (22 [12-35]%). We conclude that temporary MCS can be used to bridge patients with cardiogenic shock towards durable LVAD. Clinicians are encouraged to share their results in a large multicentre registry in order to investigate optimal device selection and best duration of support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Identification of a new target of miR-16, Vacuolar Protein Sorting 4a.

    Directory of Open Access Journals (Sweden)

    Neeta Adhikari

    Full Text Available The rationale was to utilize a bioinformatics approach to identify miRNA binding sites in genes with single nucleotide mutations (SNPs to discover pathways in heart failure (HF.The objective was to focus on the genes containing miRNA binding sites with miRNAs that were significantly altered in end-stage HF and in response to a left ventricular assist device (LVAD.BEDTools v2.14.3 was used to discriminate SNPs within predicted 3'UTR miRNA binding sites. A member of the miR-15/107 family, miR-16, was decreased in the circulation of end-stage HF patients and increased in response to a LVAD (p<0.001. MiR-16 decreased Vacuolar Protein Sorting 4a (VPS4a expression in HEK 293T cells (p<0.01. The SNP rs16958754 was identified in the miR-15/107 family binding site of VPS4a which abolished direct binding of miR-16 to the 3'UTR of VPS4a (p<0.05. VPS4a was increased in the circulation of end-stage HF patients (p<0.001, and led to a decrease in the number of HEK 293T cells in vitro (p<0.001.We provide evidence that miR-16 decreases in the circulation of end-stage HF patients and increases with a LVAD. Modeling studies suggest that miR-16 binds to and decreases expression of VPS4a. Overexpression of VPS4a decreases cell number. Together, these experiments suggest that miR-16 and VPS4a expression are altered in end-stage HF and in response to unloading with a LVAD. This signaling pathway may lead to reduced circulating cell number in HF.

  8. Frailty and outcomes after implantation of left ventricular assist device as destination therapy.

    Science.gov (United States)

    Dunlay, Shannon M; Park, Soon J; Joyce, Lyle D; Daly, Richard C; Stulak, John M; McNallan, Sheila M; Roger, Véronique L; Kushwaha, Sudhir S

    2014-04-01

    Frailty is recognized as a major prognostic indicator in heart failure. There has been interest in understanding whether pre-operative frailty is associated with worse outcomes after implantation of a left ventricular assist device (LVAD) as destination therapy. Patients undergoing LVAD implantation as destination therapy at the Mayo Clinic, Rochester, Minnesota, from February 2007 to June 2012, were included in this study. Frailty was assessed using the deficit index (31 impairments, disabilities and comorbidities) and defined as the proportion of deficits present. We divided patients based on tertiles of the deficit index (>0.32 = frail, 0.23 to 0.32 = intermediate frail, <0.23 = not frail). Cox proportional hazard regression models were used to examine the association between frailty and death. Patients were censored at death or last follow-up through October 2013. Among 99 patients (mean age 65 years, 18% female, 55% with ischemic heart failure), the deficit index ranged from 0.10 to 0.65 (mean 0.29). After a mean follow-up of 1.9 ± 1.6 years, 79% of the patients had been rehospitalized (range 0 to 17 hospitalizations, median 1 per person) and 45% had died. Compared with those who were not frail, patients who were intermediate frail (adjusted HR 1.70, 95% CI 0.71 to 4.31) and frail (HR 3.08, 95% CI 1.40 to 7.48) were at increased risk for death (p for trend = 0.004). The mean (SD) number of days alive out of hospital the first year after LVAD was 293 (107) for not frail, 266 (134) for intermediate frail and 250 (132) for frail patients. Frailty before destination LVAD implantation is associated with increased risk of death and may represent a significant patient selection consideration. Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  9. Hepatic and renal function with successful long-term support on a continuous flow left ventricular assist device.

    Science.gov (United States)

    Deo, Salil V; Sharma, Vikas; Altarabsheh, Salah E; Hasin, Tal; Dillon, John; Shah, Ishan K; Durham, Lucian A; Stulak, John M; Daly, Richard C; Joyce, Lyle D; Park, Soon J

    2014-03-01

    Data regarding the long-term clinical effects of a continuous flow left ventricular assist device (CF-LVAD) on hepato-renal function is limited. Hence our aim was to assess changes in hepato-renal function over a one-year period in patients supported on a CF-LVAD. During the study period 126 patients underwent CF-LVAD implant. Changes in hepato-renal laboratory parameters were studied in 61/126 patients successfully supported on a CF-LVAD for period of one year. A separate cohort of a high-risk group (HCrB) of patients (56/126) with a serum creat>1.9 mg/dL (168 μmol/L) (75th percentile) or a serum bil>1.5 mg/dL (25.65 μmol/L) (75th percentile) was created. Changes in serum creatinine and bilirubin were analysed at regular intervals for this group along with the need for renal replacement therapy. Baseline creatinine and blood urea nitrogen (BUN) for the entire cohort was 1.4[1.2,1.9 mg/dL] [123.7(106,168) μmol/L) and 27[20,39.5 mg/dL] [9.6(7.1,14.1) mmol/L] respectively. After an initial reduction at the end of one month [1(0.8,1.2) mg/dL; 88(70,105) μmol/L] (passist device support for one year. High-risk patients demonstrate a higher 30-day mortality and temporary need for renal replacement therapy. Yet even in this cohort, improvement is present over a period of one year on the device, with a minimal need for permanent haemodialysis. Copyright © 2013 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  10. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  11. Impella 2.5 initiated prior to unprotected left main PCI in acute myocardial infarction complicated by cardiogenic shock improves early survival.

    Science.gov (United States)

    Meraj, Perwaiz M; Doshi, Rajkumar; Schreiber, Theodore; Maini, Brijeshwar; O'Neill, William W

    2017-06-01

    To assess post-procedural outcomes when Impella 2.5 percutaneous left ventricular assist device (pLVAD) support is initiated either prior to or after percutaneous coronary intervention (PCI) on unprotected left main coronary artery (ULMCA) culprit lesion in the context of acute myocardial infarction cardiogenic shock (AMICS). Initiation of Impella 2.5 pLVAD prior to PCI is associated with significant survival benefit in the setting of AMICS. Outcomes of those presenting with a ULMCA culprit lesion in this setting have not been well characterized. Thirty-six consecutive patients in the cVAD Registry supported with Impella 2.5 pLVAD for AMICS who underwent PCI on ULMCA culprit lesion were included in our multicenter study. The average age was 69.8 ± 14.2 years, 77.8% were male, 72.7% were in CS at admission, 44.4% sustained one or multiple cardiac arrests, and 30.6% had anoxic brain injury. Baseline characteristics were comparable between the Pre-PCI group (n = 20) and Post-PCI group (n = 16). Non-ST segment elevation myocardial infarction and greater coronary disease burden were significantly more frequent in the Pre-PCI group but they had significantly better survival to discharge (55.0% vs 18.8%, P = 0.041). Kaplan-Meier 30-day survival analysis showed very poor survival in Post-PCI group (48.1% vs 12.5%, Log-Rank P = 0.004). Initiation of Impella 2.5 pLVAD prior to as compared with after PCI of ULMCA for AMICS culprit lesion is associated with significant early survival. As previously described, patients supported after PCI appear to have very poor survival at 30 days. © 2017, Wiley Periodicals, Inc.

  12. Coordination behavior of tetraaza [N4] ligand towards Co(II), Ni(II), Cu(II), Cu(I) and Pd(II) complexes: Synthesis, spectroscopic characterization and anticancer activity

    Science.gov (United States)

    El-Boraey, Hanaa A.

    2012-11-01

    Novel eight Co(II), Ni(II), Cu(II), Cu(I) and Pd(II) complexes with [N4] ligand (L) i.e. 2-amino-N-{2-[(2-aminobenzoyl)amino]ethyl}benzamide have been synthesized and structurally characterized by elemental analysis, spectral, thermal (TG/DTG), magnetic, and molar conductivity measurements. On the basis of IR, mass, electronic and EPR spectral studies an octahedral geometry has been proposed for Co(II), Ni(II) complexes and Cu(II) chloride complex, square-pyramidal for Cu(I) bromide complex. For Cu(II) nitrate complex (6), Pd(II) complex (8) square planar geometry was proposed. The EPR data of Cu(II) complexes in powdered form indicate dx2-y2 ground state of Cu(II) ion. The antitumor activity of the synthesized ligand and some selected metal complexes has been studied. The palladium(II) complex (8) was found to display cytotoxicity (IC50 = 25.6 and 41 μM) against human breast cancer cell line MCF-7 and human hepatocarcinoma HEPG2 cell line.

  13. Heavy metal phytoremediation from a meta-analytical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Audet, Patrick [Ottawa-Carleton Institute of Biology, Department of Biology, University of Ottawa, 30 Marie-Curie St., Ottawa, Ont. K1N 6N5 (Canada)]. E-mail: paude086@uottawa.ca; Charest, Christiane [Ottawa-Carleton Institute of Biology, Department of Biology, University of Ottawa, 30 Marie-Curie St., Ottawa, Ont. K1N 6N5 (Canada)]. E-mail: ccharest@science.uottawa.ca

    2007-05-15

    We conducted a literature survey and correlated heavy metal (HM) uptake and plant growth factors from published data to estimate the effectiveness of phytoextraction. The indicators of the actual plant HM uptake showed positive correlations with soil-HM concentrations, while the relative plant HM uptake showed negative correlations. Plant growth was negatively correlated with both the plant and soil-HM concentrations. These significant relationships were found for the majority of HM tested (e.g. Zn, Cd, Pb, Cu, Cr, and Fe) with a few exceptions (e.g. Ni, Co, and Mn). After fitting the correlation coefficients, the highest proportion of variance among the studies was mainly due to the experimental parameters or the plant species. When the metabolic costs of HM uptake are taken into account, the phytoextraction appears to be less effective beyond critical HM concentrations. Despite these constraints, it is emphasized that HM phytoextraction can play an important role in bioremediation. - This meta-analytical approach has revealed a compromise between growth and HM uptake when plants are subjected to toxic soil-HM levels.

  14. Heavy metal phytoremediation from a meta-analytical perspective

    International Nuclear Information System (INIS)

    Audet, Patrick; Charest, Christiane

    2007-01-01

    We conducted a literature survey and correlated heavy metal (HM) uptake and plant growth factors from published data to estimate the effectiveness of phytoextraction. The indicators of the actual plant HM uptake showed positive correlations with soil-HM concentrations, while the relative plant HM uptake showed negative correlations. Plant growth was negatively correlated with both the plant and soil-HM concentrations. These significant relationships were found for the majority of HM tested (e.g. Zn, Cd, Pb, Cu, Cr, and Fe) with a few exceptions (e.g. Ni, Co, and Mn). After fitting the correlation coefficients, the highest proportion of variance among the studies was mainly due to the experimental parameters or the plant species. When the metabolic costs of HM uptake are taken into account, the phytoextraction appears to be less effective beyond critical HM concentrations. Despite these constraints, it is emphasized that HM phytoextraction can play an important role in bioremediation. - This meta-analytical approach has revealed a compromise between growth and HM uptake when plants are subjected to toxic soil-HM levels

  15. Dynamics of arbuscular mycorrhizal symbiosis in heavy metal phytoremediation: Meta-analytical and conceptual perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Audet, Patrick [Ottawa-Carleton Institute of Biology, Department of Biology, University of Ottawa, 30 Marie-Curie Street, Ottawa, ON, K1N 6N5 (Canada)]. E-mail: paude086@uottawa.ca; Charest, Christiane [Ottawa-Carleton Institute of Biology, Department of Biology, University of Ottawa, 30 Marie-Curie Street, Ottawa, ON, K1N 6N5 (Canada)]. E-mail: ccharest@science.uottawa.ca

    2007-06-15

    To estimate dynamics of arbuscular mycorrhizal (AM) symbiosis in heavy metal (HM) phytoremediation, we conducted a literature survey and correlated HM uptake and relative plant growth parameters from published data. After estimating AM feedback responses for these parameters at low and high soil-HM concentration intervals, we determined that the roles of AM symbiosis are characterized by (1) an increased HM phytoextraction via mycorrhizospheric 'Enhanced Uptake' at low soil-HM concentrations, and (2) a reduced HM bioavailability via AM fungal 'Metal-Binding' processes at high soil-HM levels, hence resulting in increased plant biomass and enhanced plant tolerance through HM stress-avoidance. We present two conceptual models which illustrate the important compromise between plant growth, plant HM uptake and HM tolerance, and further emphasize the importance of AM symbiosis in buffering the soil environment for plants under such stress conditions. - This meta-analysis has revealed a transition role of the AM symbiosis in phytoremediation shifting from 'Enhanced Uptake' to 'Metal-Binding' beyond critical soil-HM levels.

  16. Estimating areas threatened by contamination from leaking chemical warfare agents dumped into the Baltic Sea

    Science.gov (United States)

    Jakacki, Jaromir; Przyborska, Anna; Andrzejewski, Jan

    2017-04-01

    Approximately 60,000 tons of chemical munitions were dumped into the Baltic Sea after World War II (the exact amount is unknown and some sources estimate it as more than 200,000 tons). Dumped munitions still pose a risk of leakage caused by erosion and corrosion, and it is important to know the danger areas. Because of wide dispersion of the dumped munitions, modelling is only one tool that could provide wide image of physical state of the sea at all locations and which could also be used for analysing contamination during a potential leakage. Obviously, it is possible to take samples at each dumpsite, but modelling also allows to develop possible scenarios of leakages under specific physical conditions. For the purpose of analysis of potential leakage a high-resolution model (HRM) of the contamination will be embedded in the hydrodynamic model (HM) of the Baltic Sea. The HRM will use data from general circulation model results of estimated resolution of nearly 2 km. The Parallel Ocean Program will be implemented as the HM for the whole Baltic Sea. Atmospheric data from regional implementation of the Weather Research and Forecasting System (WRF) have been used as the top boundary conditions of the HM, and sea level data from Gothenburg had been included into model barotropic equation as lateral boundary conditions. Passive tracer will represent the contamination in the HRM and horizontal resolution of the HRM will be close to 50 meters. Passive tracers will also be implemented in the HM - for comparison of the results. For proper representation of potential leakage of chemical warfare agents the HRM will have included diffusion and advection processes. The results from the HM are going to be interpolated into the HRM domain and then integration will be performed. Based on the implemented simulations, estimated contaminated area and its comparison from the HRM as well as from the HM will be presented. The research work was fund by the European Union (European

  17. Classification of hydromagnetic emissions based on frequency--time spectra

    International Nuclear Information System (INIS)

    Fukunishi, H.; Toya, T.; Koike, K.; Kuwashima, M.; Kawamura, M.

    1981-01-01

    By using 3035 hydromagnetic emission events observed in the frequency range of 0.1--2.0 Hz at Syowa (Lapprox.6), HM emissions have been classified into eight subtypes based on their spectral structures, i.e., HM whistler, periodic HM emission, HM chorus, HM emission burst, IPDP, morning IPDP, Pc 1--2 band, and irregular HM emission. It is seen that each subtype has a preferential magnetic local time interval and also a frequency range for its occurrence. Morning IPDP events and irregular HM emissions occur in the magnetic morning hours, while dispersive periodic HM emissions and HM emission bursts occur around magnetic local noon, then HM chorus emissions occur in the afternoon hours and IPDP events occur in the evening hours. Furthermore, it is noticed that the mid-frequencies of these emissions vary from high frequencies in the morning hours to low frequencies in the afternoon hours. On the basis of these results, the generation mechanisms of each subtype are discussed

  18. Herbal Medicines: challenges in the modern world. Part 5. status and current directions of complementary and alternative herbal medicine worldwide.

    Science.gov (United States)

    Enioutina, Elena Yu; Salis, Emma R; Job, Kathleen M; Gubarev, Michael I; Krepkova, Lubov V; Sherwin, Catherine M T

    2017-03-01

    Herbal medicine (HM) use is growing worldwide. Single herb preparations, ethnic and modern HM formulations are widely used as adjunct therapies or to improve consumer wellbeing. Areas covered: This final part in the publication series summarizes common tendencies in HM use as adjunct or alternative medicine, education of healthcare professionals and consumers, current and proposed guidelines regulating of production. We discuss potential HM-HM and HM-drug interactions that could lead to severe adverse events in situations where HMs are taken without proper medical professional oversight. Expert commentary: A number of serious problems have arisen with the steady global increase in HM use. HM interaction with conventional drugs (CD) may result in inadequate dosing of CD or adverse reactions; HM-HM interaction within herbal supplements could lead to toxicity of formulations. Inadequate education of clinicians and patients regarding medicinal properties of HMs must be addressed regionally and globally to ensure consumer safety.

  19. Comprehensive evaluation of genome-wide 5-hydroxymethylcytosine profiling approaches in human DNA.

    Science.gov (United States)

    Skvortsova, Ksenia; Zotenko, Elena; Luu, Phuc-Loi; Gould, Cathryn M; Nair, Shalima S; Clark, Susan J; Stirzaker, Clare

    2017-01-01

    The discovery that 5-methylcytosine (5mC) can be oxidized to 5-hydroxymethylcytosine (5hmC) by the ten-eleven translocation (TET) proteins has prompted wide interest in the potential role of 5hmC in reshaping the mammalian DNA methylation landscape. The gold-standard bisulphite conversion technologies to study DNA methylation do not distinguish between 5mC and 5hmC. However, new approaches to mapping 5hmC genome-wide have advanced rapidly, although it is unclear how the different methods compare in accurately calling 5hmC. In this study, we provide a comparative analysis on brain DNA using three 5hmC genome-wide approaches, namely whole-genome bisulphite/oxidative bisulphite sequencing (WG Bis/OxBis-seq), Infinium HumanMethylation450 BeadChip arrays coupled with oxidative bisulphite (HM450K Bis/OxBis) and antibody-based immunoprecipitation and sequencing of hydroxymethylated DNA (hMeDIP-seq). We also perform loci-specific TET-assisted bisulphite sequencing (TAB-seq) for validation of candidate regions. We show that whole-genome single-base resolution approaches are advantaged in providing precise 5hmC values but require high sequencing depth to accurately measure 5hmC, as this modification is commonly in low abundance in mammalian cells. HM450K arrays coupled with oxidative bisulphite provide a cost-effective representation of 5hmC distribution, at CpG sites with 5hmC levels >~10%. However, 5hmC analysis is restricted to the genomic location of the probes, which is an important consideration as 5hmC modification is commonly enriched at enhancer elements. Finally, we show that the widely used hMeDIP-seq method provides an efficient genome-wide profile of 5hmC and shows high correlation with WG Bis/OxBis-seq 5hmC distribution in brain DNA. However, in cell line DNA with low levels of 5hmC, hMeDIP-seq-enriched regions are not detected by WG Bis/OxBis or HM450K, either suggesting misinterpretation of 5hmC calls by hMeDIP or lack of sensitivity of the latter methods. We

  20. Exercise guidelines for inpatients following ventricular assist device placement: a systematic review of the literature.

    Science.gov (United States)

    Scheiderer, Rachel; Belden, Courtney; Schwab, Darla; Haney, Casey; Paz, Jaime

    2013-06-01

    For patients with end-stage heart failure awaiting transplantation, lack of donor organs has created an increased need for alternatives such as left ventricular assist device (LVAD) implantation. The purpose of this study is to determine safe and effective exercise parameters for physical therapy in the acute care setting. A systematic literature review was conducted according to PRISMA guidelines using Sackett's Levels of Evidence to rate the evidence. Multiple databases were searched with inclusion criteria of: available in English, inpatient care up to 6 months postoperatively, description of intervention type and exercise parameters. no defined exercise parameters, outpatient treatment, infection post VAD, or palliative or hospice care post VAD. Six studies out of 1,291 articles met inclusion criteria. Common exercise parameters used were the Borg Rating of Perceived Exertion scale 11-13 (6-20 scale) or > 4 (0-10 scale), Dyspnea scale > 2 (0-4 scale) and > 5 (0-10 scale), mean arterial pressure (MAP) 70-95 mmHg, and LVAD flow > 3L/min. Levels of evidence ranged from case controlled to expert opinion. Current evidence on inpatient exercise parameters for patient's status post LVAD implantation is not sufficient to suggest definitive guidelines; however, these exercise parameters provide a reference for patient care.

  1. Outcomes of patients with right ventricular failure on milrinone after left ventricular assist device implantation.

    Science.gov (United States)

    Tsiouris, Athanasios; Paone, Gaetano; Brewer, Robert J; Nemeh, Hassan W; Borgi, Jamil; Morgan, Jeffrey A

    2015-01-01

    Previous studies have grouped together both patients requiring right ventricular assist devices (RVADs) with patients requiring prolonged milrinone therapy after left ventricular assist device (LVAD) implantation. We retrospectively identified 149 patients receiving LVADs and 18 (12.1%) of which developed right ventricular (RV) failure. We then separated these patients into those requiring RVADs versus prolonged milrinone therapy. This included 10 patients who were treated with prolonged milrinone and eight patients who underwent RVAD placement. Overall, the RV failure group had worse survival compared with the non-RV failure cohort (p = 0.038). However, this was only for the subgroup of patients who required RVADs, who had a 1, 6, 12, and 24 month survival of 62.5%, 37.5%, 37.5%, and 37.5%, respectively, versus 96.8%, 92.1%, 86.7%, and 84.4% for patients without RV failure (p milrinone therapy for RV failure had similar survivals compared with patients without RV failure. In the RV failure group, age, preoperative renal failure, and previous cardiac surgery were predictors of the need for prolonged postoperative milrinone. As LVADs become a more widely used therapy for patients with refractory, end-stage heart failure, it will be important to reduce the incidence of RV failure, as it yields significant morbidity and increases cost.

  2. Our experience with implantation of VentrAssist left ventricular assist device

    Directory of Open Access Journals (Sweden)

    Hiriyur Shivalingappa Jayanthkumar

    2013-01-01

    Full Text Available Perioperative anaesthetic management of the VentrAssist TM left ventricular assist device (LVAD is a challenge for anaesthesiologists because patients presenting for this operation have long-standing cardiac failure and often have associated hepatic and renal impairment, which may significantly alter the pharmacokinetics of administered drugs and render the patients coagulopathic. The VentrAssist is implanted by midline sternotomy. A brief period of cardiopulmonary bypass (CPB for apical cannulation of left ventricle is needed. The centrifugal pump, which produces non-pulsatile, continuous flow, is positioned in the left sub-diaphragmatic pocket. This LVAD is preload dependent and afterload sensitive. Transoesophageal echocardiography is an essential tool to rule out contraindications and to ensure proper inflow cannula position, and following the implantation of LVAD, to ensure right ventricular (RV function. The anaesthesiologist should be prepared to manage cardiac decompensation and acute desaturation before initiation of CPB, as well as RV failure and severe coagulopathic bleeding after CPB. Three patients had undergone implantation of VentrAssist in our hospital. This pump provides flow of 5 l/min depending on preload, afterload and pump speed. All the patients were discharged after an average of 30 days. There was no perioperative mortality.

  3. Removal of nickel(II and palladium(II from surface waters

    Directory of Open Access Journals (Sweden)

    V. Sharifzade

    2013-04-01

    Full Text Available A new sorbent was prepared using alumina and 5-Br-PADAP, and its adsorption ability for the removal of Ni(II and Pd(II from different waters was investigated. The procedure is based on retention of the analytes on the alumina load with 5-Br-PADAP at pH ~ 6. The separation/preconcentration conditions for the quantitative recoveries were investigated. The limit of detections (LOD based on three times the standard deviations of the blank, were 0.187 and 0.253 ng mL-1 for Ni(II and Pd(II, respectively. Obtained sorption capacities for 1 g sorbent were 6.0 mg Ni(II and 11.0 mg Pd(II. The linearity was maintained in the concentration range of 0.625 to 6.0 ng mL-1 for Ni(II and 0.416 to 7.0 ng mL-1 for Pd(II in the original solution. Eight replicate determinations of a mixture containing 2.0 µg mL-1 each of the elements in the final solution gave relative standard deviation of ±0.82 and ±1.12% for Ni(II and Pd(II, respectively. The proposed method was successfully applied to the determination trace amounts of Ni(II and Pd(II in the surface water samples.DOI: http://dx.doi.org/10.4314/bcse.v27i1.2

  4. Plaadid / Mart Normet

    Index Scriptorium Estoniae

    Normet, Mart, 1979-

    2006-01-01

    Uutest heliplaatidest Vaiko Eplik ja Eliit "1", Scandinavian Music Group "Hölmö Rakkaus Ylpeä Sydän", No Big Silence "War In Wonderland", Cool Calm Pete "Lost", A-Rühm "Leegion", "Ruuhkatukka vol 2", "Broken Dreams II", Jane Birkin "Fictions", Joe Satriani "Super Colossal", The Ipanemas "Samba Is Our Gift", "The Little Willies", The Shapeshifters "Sound Advice", Röyksopp "Röykspopp's Night Out", Pink "I'm Not Dead"

  5. Evaluation of the computerized procedures Manual II (COPMA II)

    International Nuclear Information System (INIS)

    Converse, S.A.

    1995-11-01

    The purpose of this study was to evaluate the effects of a computerized procedure system, the Computerized Procedure Manual II (COPMA-II), on the performance and mental workload of licensed reactor operators. To evaluate COPMA-II, eight teams of two operators were trained to operate a scaled pressurized water reactor facility (SPWRF) with traditional paper procedures and with COPMA-II. Following training, each team operated the SPWRF under normal operating conditions with both paper procedures and COPMA-II. The teams then performed one of two accident scenarios with paper procedures, but performed the remaining accident scenario with COPMA-II. Performance measures and subjective estimates of mental workload were recorded for each performance trial. The most important finding of the study was that the operators committed only half as many errors during the accident scenarios with COPMA-II as they committed with paper procedures. However, time to initiate a procedure was fastest for paper procedures for accident scenario trials. For performance under normal operating conditions, there was no difference in time to initiate or to complete a procedure, or in the number of errors committed with paper procedures and with COPMA-II. There were no consistent differences in the mental workload ratings operators recorded for trials with paper procedures and COPMA-II

  6. Efficiency of Chitosan for the Removal of Pb (II, Fe (II and Cu (II Ions from Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Soheil Sobhanardakani

    2014-09-01

    Full Text Available Background: Heavy metals have been recognized as harmful environmental pollutant known to produce highly toxic effects on different organs and systems of both humans and animals. The aim of this paper is to evaluate the adsorption potential of chitosan for the removal of Pb(II, Fe(II and Cu(II ions from aqueous solutions. Methods: This study was conducted in laboratory scale. In this paper chitosan has been used as an adsorbent for the removal of Pb(II, Fe(II and Cu(II from aqueous solution. In batch tests, the effects of parameters like pH solution (1.0-8.0, initial metal concentrations (100-1000 mgL-1, contact time (5.0-150 min and adsorbent dose (1.0-7.0 g on the adsorption process were studied. Results: The results showed that the adsorption of Pb(II, Fe(II and Cu(II ions on chitosan strongly depends on pH. The experimental isothermal data were analyzed using the Langmuir and Freundlich equations and it was found that the removal process followed the Langmuir isotherm and maximum adsorption capacity for the adsorption of Pb(II, Fe(II and Cu(II ions by the chitosan were 55.5mg g−1, 71.4 mg g−1 and 59 mg g−1, respectively, under equilibrium conditions at 25±1 ºC. The adsorption process was found to be well described by the pseudo-second-order rate model. Conclusion: The obtained results showed that chitosan is a readily, available, economic adsorbent and was found suitable for removing Pb(II, Fe(II and Cu(II ions from aqueous solution.

  7. Spectrophotometric determination of cobalt(II), nickel(II) and copper (II) with 1-(2 pyridylazo)-2-naphthol in micellar medium

    International Nuclear Information System (INIS)

    Shar, G.A.; Soomro, G.A.

    2004-01-01

    Spectrophotometric determination of cobalt(II), nickel(II) and copper(II) is carried out with 1-(2 pyridylazo)-2-naphthol as a complexing reagent in aqueous phase using non-ionic surfactant Tween 80. Beer's law is obeyed for Co(II), Ni(II) and Cu(II) over the range 0.5 - 4.0, 0.5 - 4.0 and 0.5 - 3.0 ngmL/sup -1/ with detection limit (2 σ) of 6.7, 3.2 and 3.9 ngmL/sup -1/. The max molar absorption, molar absorptivity, Sandell's sensitivity of Co(II), Ni(II) and Cu(II) are 580 nm, 570 nm and 555 nm; max (104 mol/sup -1/ cm /sup -1/) is 0.87, 1.8 and 1.6 and 6.8, 3.3 and 3.9 ng cm-2 respectively. The pH at which complex is formed for Co(II), Ni(II) and Cu(II) is 5, 5.5 and 6.5 respectively. The critical micelle concentration (CMC) of Tween 80 is 5%. The present method is compared with that of atomic absorption spectroscopy and no significant difference is noted between the two methods at 95% confidence level. The method has been applied to the determination of Co(II), Ni(II) and Cu(II) in industrial waste water and pharmaceutical samples. (author)

  8. Synthesis, spectral characterization thermal stability, antimicrobial studies and biodegradation of starch–thiourea based biodegradable polymeric ligand and its coordination complexes with [Mn(II, Co(II, Ni(II, Cu(II, and Zn(II] metals

    Directory of Open Access Journals (Sweden)

    Nahid Nishat

    2016-09-01

    Full Text Available A biodegradable polymer was synthesized by the modification reaction of polymeric starch with thiourea which is further modified by transition metals, Mn(II, Co(II, Ni(II, Cu(II and Zn(II. All the polymeric compounds were characterized by (FT-IR spectroscopy, 1H NMR spectroscopy, 13C NMR spectroscopy, UV–visible spectra, magnetic moment measurements, thermogravimetric analysis (TGA and antibacterial activities. Polymer complexes of Mn(II, Co(II and Ni(II show octahedral geometry, while polymer complexes of Cu(II and Zn(II show square planar and tetrahedral geometry, respectively. The TGA revealed that all the polymer metal complexes are more thermally stable than their parental ligand. In addition, biodegradable studies of all the polymeric compounds were also carried out through ASTM-D-5338-93 standards of biodegradable polymers by CO2 evolution method which says that coordination decreases biodegradability. The antibacterial activity was screened with the agar well diffusion method against some selected microorganisms. Among all the complexes, the antibacterial activity of the Cu(II polymer–metal complex showed the highest zone of inhibition because of its higher stability constant.

  9. Removal of Ni (II), Co (II) and Pb (II) ions from aqueous media using ...

    African Journals Online (AJOL)

    Removal of Ni (II), Co (II) and Pb (II) ions from aqueous media using Starch ... The results showed that 0.025 % loaded SSMNPs gave the optimal sorption ... constants (Lagergren and Pseudo-2nd-order) for Ni2+ and Co2+ adsorption were ... Langmuir correlation coefficients showed a better fit for the adsorption isotherms.

  10. Selective Hg(II) adsorption from aqueous solutions of Hg(II) and Pb(II) by hydrolyzed acrylamide-grafted PET films.

    Science.gov (United States)

    Rahman, Nazia; Sato, Nobuhiro; Sugiyama, Masaaki; Hidaka, Yoshiki; Okabe, Hirotaka; Hara, Kazuhiro

    2014-01-01

    Selective Hg(II) adsorption from aqueous solutions of Hg(II) and Pb(II) using hydrolyzed acrylamide (AAm)-grafted polyethylene terephthalate (PET) films was examined to explore the potential reuse of waste PET materials. Selective recovery of Hg(II) from a mixture of soft acids with similar structure, such as Hg(II) and Pb(II), is important to allow the reuse of recovered Hg(II). An adsorbent for selective Hg(II) adsorption was prepared by γ-ray-induced grafting of AAm onto PET films followed by partial hydrolysis through KOH treatment. The adsorption capacity of the AAm-grafted PET films for Hg(II) ions increased from 15 to 70 mg/g after partial hydrolysis because of the reduction of hydrogen bonding between -CONH2 groups and the corresponding improved access of metal ions to the amide groups. The prepared adsorbent was characterized by Fourier transform infrared spectroscopy and scanning electron microscopy. The absorbent film showed high selectivity for the adsorption of Hg(II) over Pb(II) throughout the entire initial metal concentration range (100-500 mg/L) and pH range (2.2-5.6) studied. The high selectivity is attributed to the ability of Hg(II) ions to form covalent bonds with the amide groups. The calculated selectivity coefficient for the adsorbent binding Hg(II) over Pb(II) was 19.2 at pH 4.5 with an initial metal concentration of 100 mg/L. Selective Hg(II) adsorption equilibrium data followed the Langmuir model and kinetic data were well fitted by a pseudo-second-order equation. The adsorbed Hg(II) and Pb(II) ions were effectively desorbed from the adsorbent film by acid treatment, and the regenerated film showed no marked loss of adsorption capacity upon reuse for selective Hg(II) adsorption.

  11. New Mn(II, Ni(II, Cd(II, Pb(II complexes with 2-methylbenzimidazole and other ligands. Synthesis, spectroscopic characterization, crystal structure, magnetic susceptibility and biological activity studies

    Directory of Open Access Journals (Sweden)

    Shayma A. Shaker

    2016-11-01

    Full Text Available Synthesis and characterization of Mn(II, Ni(II, Cd(II and Pb(II mixed ligand complexes of 2-methylbenzimidazole with other ligands have been reported. The structure of the ligands and their complexes was investigated using elemental analysis, IR, UV–Vis, (1H, 13C NMR spectroscopy, molar conductivity and magnetic susceptibility measurements. In all the studies of complexes, the 2-methylbenzimidazole behaves as a neutral monodentate ligand which is coordinated with the metal ions through the N atom. While benzotriazole behaves as a neutral bidentate ligand which is coordinated with the Ni(II ion through the two N atoms. Moreover, the N-acetylglycine behaves as a bidentate ligand which is coordinated with the Mn(II, Ni(II and Pb(II ions through the N atom and the terminal carboxyl oxygen atom. The magnetic and spectral data indicate the tetrahedral geometry for Mn(II complex, irregular tetrahedral geometry for Pb(II complex and octahedral geometry for Ni(II complex. The X-ray single crystal diffraction method was used to confirm a centrosymmetric dinuclear Cd(II complex as each two metal ions are linked by a pair of thiocyanate N = S bridge. Two 2-methylbenzimidazole N-atom donors and one terminal thiocyanate N atom complete a highly distorted square pyramid geometry around the Cd atom. Besides, different cell types were used to determine the inhibitory effect of Mn(II, Ni(II, Cd(II and Pb(II complexes on cell growth using MTT assay. Cd(II complex showed cytotoxic effect on various types of cancer cell lines with different EC50 values.

  12. Chelation of Cu(II, Zn(II, and Fe(II by Tannin Constituents of Selected Edible Nuts

    Directory of Open Access Journals (Sweden)

    Magdalena Karamać

    2009-12-01

    Full Text Available The tannin fractions isolated from hazelnuts, walnuts and almonds were characterised by colorimetric assays and by an SE-HPLC technique. The complexation of Cu(II and Zn(II was determined by the reaction with tetramethylmurexide, whereas for Fe(II, ferrozine was employed. The walnut tannins exhibited a significantly weaker reaction with the vanillin/HCl reagent than hazelnut and almond tannins, but the protein precipitation capacity of the walnut fraction was high. The SE-HPLC chromatogram of the tannin fraction from hazelnuts revealed the presence of oligomers with higher molecular weights compared to that of almonds. Copper ions were most effectively chelated by the constituents of the tannin fractions of hazelnuts, walnuts and almonds. At a 0.2 mg/assay addition level, the walnut tannins complexed almost 100% Cu(II. The Fe(II complexation capacities of the tannin fractions of walnuts and hazelnuts were weaker in comparison to that of the almond tannin fraction, which at a 2.5 mg/assay addition level, bound Fe(II by ~90%. The capacity to chelate Zn(II was quite varied for the different nut tannin fractions: almond tannins bound as much as 84% Zn(II, whereas the value for walnut tannins was only 8.7%; and for hazelnut tannins, no Zn(II chelation took place at the levels tested.

  13. Stability constants of glutarate complexes of copper(II), zinc(II), cobalt(II) and uranyl(II) by paper electrophoresis

    International Nuclear Information System (INIS)

    Singh, R.K.P.; Yadava, J.R.; Yadava, K.L.

    1981-01-01

    Stability constants of Copper(II), Zinc(II), Cobalt(II) and Uranyl(II) glutarates have been determined by paper electrophoresis. Glutaric acid (0.005 mol dmsup(-3)) was added to the background electrolyte : 0.1 mol dmsup(-3) HClO 4 . The proportions of (CH 2 ) 3 COOH COO - and (CH 2 ) 3 C 2 O 4 2- were varied by changing the pH of the electrolyte. These anions yielded the complexes Cu(CH 2 ) 3 C 2 O 4 , [Zn(CH 2 ) 3 COOH COO] + [Co(CH 2 ) 3 COOH COO] + and UO 2 (CH 2 ) 3 C 2 O 4 whose stability constants are found to be 10sup(3.9), 10sup(2.9), 10sup(2.7) and 10sup(13.5) respectively. (author)

  14. Pb(II), Cd(II) and Zn(II) adsorption on low grade manganese ore ...

    African Journals Online (AJOL)

    Low grade manganese ore (LMO) of Orissa containing 58.37% SiO2, 25.05% MnO2, 8.8% Al2O3, and 5.03% Fe2O3 as the main constituents was taken to study its adsorption behaviour for Pb(II), Cd(II) and Zn(II) from aqueous solutions. The XRD studies showed the crystalline phases to be quartz, ß-MnO2, d-MnO2 and ...

  15. Utility of the Seattle Heart Failure Model in patients with advanced heart failure.

    Science.gov (United States)

    Kalogeropoulos, Andreas P; Georgiopoulou, Vasiliki V; Giamouzis, Grigorios; Smith, Andrew L; Agha, Syed A; Waheed, Sana; Laskar, Sonjoy; Puskas, John; Dunbar, Sandra; Vega, David; Levy, Wayne C; Butler, Javed

    2009-01-27

    The aim of this study was to validate the Seattle Heart Failure Model (SHFM) in patients with advanced heart failure (HF). The SHFM was developed primarily from clinical trial databases and extrapolated the benefit of interventions from published data. We evaluated the discrimination and calibration of SHFM in 445 advanced HF patients (age 52 +/- 12 years, 68.5% male, 52.4% white, ejection fraction 18 +/- 8%) referred for cardiac transplantation. The primary end point was death (n = 92), urgent transplantation (n = 14), or left ventricular assist device (LVAD) implantation (n = 3); a secondary analysis was performed on mortality alone. Patients were receiving optimal therapy (angiotensin-II modulation 92.8%, beta-blockers 91.5%, aldosterone antagonists 46.3%), and 71.0% had an implantable device (defibrillator 30.4%, biventricular pacemaker 3.4%, combined 37.3%). During a median follow-up of 21 months, 109 patients (24.5%) had an event. Although discrimination was adequate (c-statistic >0.7), the SHFM overall underestimated absolute risk (observed vs. predicted event rate: 11.0% vs. 9.2%, 21.0% vs. 16.6%, and 27.9% vs. 22.8% at 1, 2, and 3 years, respectively). Risk underprediction was more prominent in patients with an implantable device. The SHFM had different calibration properties in white versus black patients, leading to net underestimation of absolute risk in blacks. Race-specific recalibration improved the accuracy of predictions. When analysis was restricted to mortality, the SHFM exhibited better performance. In patients with advanced HF, the SHFM offers adequate discrimination, but absolute risk is underestimated, especially in blacks and in patients with devices. This is more prominent when including transplantation and LVAD implantation as an end point.

  16. Effect of large-scale pig farm waste water on wheat yield and quality%规模化养猪场处理污水施用对小麦产量和品质的影响

    Institute of Scientific and Technical Information of China (English)

    朱正杰; 高威; 庄恒扬

    2012-01-01

    随着我国规模化养猪场迅速发展,排放的粪尿污水不断增加,导致严重的环境污染,成为规模化养猪可持续发展亟待解决的问题.种养结合是污水最佳处理利用途径.规模化养猪场污水在农田特别是在农场经营条件下应用的技术缺少系统研究,本研究通过田间试验探讨实现小麦高产优质高效的污水利用技术,为规模化养猪场-农田种植循环农业模式的应用提供技术支持.试验所用污水为养猪场粪尿和冲洗废水经过充分发酵后的污水,污水含全氮1000 mg·L-1、速效氮540 mg·L-1、速效磷779 mg·L-1.在常规基施化肥基础上,设计小麦越冬期施入0 m3·hm-2、30 m3·hm-2、60 m3·hm-2、90 m3·hm-2、120 m3·hm-2的污水与穗期施氮肥0kg(N)·hm-2、30 kg(N)·hm-2、60 kg(N)·hm-2、90 kg(N)·hm-2组合为处理,研究对小麦产量和品质的影响.结果表明,越冬期施污水30 m3·hm-2、60 m3·hm-2或90 m3·hm-2与穗期施氮60 kg(N)·hm-2相结合的3个处理产量分别为8 496.27 kg·hm-2、8 372.28 kg·hm-2、8 419.97 kg·hm-2,与大田常规施肥的产量8 305.52 kg·hm-2相当,穗期不追施或施氮量30 kg(N).hm-2处理,产量都低于常规施肥产量,说明越冬期污水施用必须与一定量化肥配合才能获得理想的产量,在品质方面,穗期不施氮肥或施氮30 kg(N)·hm-2处理的籽粒蛋白质含量都低于中筋小麦下限13%的要求.从产量与品质两方面考虑,污水施用量60 m3·hm-2与穗期施氮90 kg(N).hm-2组合、污水施用量90 m3.hm-2与穗期施氮60 kg(N)·hm-2处理均为较优的施肥方案.再考虑到农田较大污水承载量和减少化肥施用的目标,污水施用量为90 m3·hm-2、穗期施氮60 kg(N)·hm-2处理为小麦优质高产高效的污水施用方案.%With the rapid development of China's large-scale pig farms, increasing manure and sewage discharge is causing severe environmental pollution that in turn threatens the sustainable

  17. Crystal Structure of Rat Carnitine Palmitoyltransferase II (CPT-II)

    Energy Technology Data Exchange (ETDEWEB)

    Hsiao,Y.; Jogl, G.; Esser, V.; Tong, L.

    2006-01-01

    Carnitine palmitoyltransferase II (CPT-II) has a crucial role in the {beta}-oxidation of long-chain fatty acids in mitochondria. We report here the crystal structure of rat CPT-II at 1.9 Angstroms resolution. The overall structure shares strong similarity to those of short- and medium-chain carnitine acyltransferases, although detailed structural differences in the active site region have a significant impact on the substrate selectivity of CPT-II. Three aliphatic chains, possibly from a detergent that is used for the crystallization, were found in the structure. Two of them are located in the carnitine and CoA binding sites, respectively. The third aliphatic chain may mimic the long-chain acyl group in the substrate of CPT-II. The binding site for this aliphatic chain does not exist in the short- and medium-chain carnitine acyltransferases, due to conformational differences among the enzymes. A unique insert in CPT-II is positioned on the surface of the enzyme, with a highly hydrophobic surface. It is likely that this surface patch mediates the association of CPT-II with the inner membrane of the mitochondria.

  18. Usefulness of {sup 123}I-MIBG myocardial scintigraphy for determining the severity and prognosis in chronic hemodialysis patients with congestive heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Tsukamoto, Masaki; Kato, Shuji; Okamoto, Akio; Kawasaki, Tatsuya; Yamamoto, Teruyuki; Yoneyama, Satoshi; Tatsukawa, Hirotaka; Ida, Kazunori [Asahi Univ., Hozumi, Gifu (Japan). Murakami Memorial Hospital; Terada, Koji

    1997-11-01

    The subjects were 32 patients who had undergone hemodialysis treatment for an average of 17 yr. MIBG myocardial scintigraphy was obtained from SPECT and anterior planar images at 15 min and 4 hr after MIBG injection. Myocardial MIBG uptake was quantified by the heart-to-mediastinum uptake ratio on delayed planar images (H/M) and the mean myocardial MIBG washout rate at 4 hr was calculated by using the Bull`s eye map (MC). The mean lung MIBG washout rate at 4 hr was also obtained from planar images (LC). The left ventricular end diastolic dimension (LVDd), percent fractional shortening (%FS), wall thickness and the ratio of peak velocity of early rapid filling to peak velocity of inflow due to the atrial contraction (E/A) were measured by echocardiography. The patients were divided according to the severity of congestive heart failure (CHF): NYHA classification grade I or II vs. grade III or IV. The severe CHF group showed decreased H/M, LC and dilatation of LVDd. Twenty-two patients were clinically followed up for one and a half years. Seven had acute worsening of CHF and required admission to a hospital. The other 15 patients did not require admission. H/M and LC were decreased, and E/A was increased in the former group. Eighteen of the 24 patients with mild CHF were followed up and classified according to the clinical course whether or not they had acute worsening of CHF. In the acute worsening group, H/M and LC were decreased, and E/A was increased compared with the non-acute worsening group. Thus, H/M and LC indicate the severity and the prognosis of chronic hemodialysis patients with CHF. Dilatation of LVDd reflects the severity of CHF, but it cannot predict the clinical course, because LVDd is always reduced by the medication for CHF. Increased E/A was found in the acute worsening CHF group, but many factors influence the E/A value and increased E/A alone cannot be prognostic for the clinical course of CHF. (K.H.)

  19. Multi-metals column adsorption of lead(II), cadmium(II) and manganese(II) onto natural bentonite clay.

    Science.gov (United States)

    Alexander, Jock Asanja; Surajudeen, Abdulsalam; Aliyu, El-Nafaty Usman; Omeiza, Aroke Umar; Zaini, Muhammad Abbas Ahmad

    2017-10-01

    The present work was aimed at evaluating the multi-metals column adsorption of lead(II), cadmium(II) and manganese(II) ions onto natural bentonite. The bentonite clay adsorbent was characterized for physical and chemical properties using X-ray diffraction, X-ray fluorescence, Brunauer-Emmett-Teller surface area and cation exchange capacity. The column performance was evaluated using adsorbent bed height of 5.0 cm, with varying influent concentrations (10 mg/L and 50 mg/L) and flow rates (1.4 mL/min and 2.4 mL/min). The result shows that the breakthrough time for all metal ions ranged from 50 to 480 minutes. The maximum adsorption capacity was obtained at initial concentration of 10 mg/L and flow rate of 1.4 mL/min, with 2.22 mg/g of lead(II), 1.71 mg/g of cadmium(II) and 0.37 mg/g of manganese(II). The order of metal ions removal by natural bentonite is lead(II) > cadmium(II) > manganese(II). The sorption performance and the dynamic behaviour of the column were predicted using Adams-Bohart, Thomas, and Yoon-Nelson models. The linear regression analysis demonstrated that the Thomas and Yoon-Nelson models fitted well with the column adsorption data for all metal ions. The natural bentonite was effective for the treatment of wastewater laden with multi-metals, and the process parameters obtained from this work can be used at the industrial scale.

  20. Production and characterization of biodiesel derived from Hodgsonia macrocarpa seed oil

    International Nuclear Information System (INIS)

    Cao, Leichang; Zhang, Shicheng

    2015-01-01

    Highlights: • The oil content of HM seed was 71.65 wt%. The HM biodiesel yield was 95.46 wt%. • HM biodiesel satisfied ASTM D6751 and EN 14214 standards, with the exception of OS. • The transportation safety and cold flow properties of HM biodiesel were excellent. • After treatment with 400 ppm TBHQ, the OS of HM biodiesel satisfied EN 14214. - Abstract: Using inexpensive and high-quality oil feedstock is an effective means to produce low-cost biodiesel. This work investigated the production and fuel properties of biodiesel derived from Hodgsonia macrocarpa (HM). The oil content of HM seed was 71.65 wt%, which is much higher than that of many potential oil plants. With traditional base-catalyzed transesterification, biodiesel was readily prepared from HM seed oil. The biodiesel yield was 95.46 wt% from HM seed oil. Biodiesel derived from HM met all ASTM D6751 and EN 14214 specifications, except for oxidative stability (OS). The OS specifications of the two biodiesel standards were met after treatment of HM biodiesel with 400 ppm tertbutyl hydroquinone. The biodiesel exhibited excellent transportation safety and cold flow properties, with flash point of 153 °C, pour point of −9 °C, and cold filter plugging point of −7 °C

  1. Antibacterial Co(II, Ni(II, Cu(II and Zn(II complexes with biacetyl-derived Schiff bases

    Directory of Open Access Journals (Sweden)

    MUHAMMAD IMRAN

    2010-08-01

    Full Text Available The condensation reactions of biacetyl with ortho-hydroxyaniline and 2-aminobenzoic acid to form bidendate NO donor Schiff bases were studied. The prepared Schiff base ligands were further utilized for the formation of metal chelates having the general formula [ML2(H2O2] where M = Co(II, Ni(II, Cu(II and Zn(II and L = HL1 and HL2. These new compounds were characterized by conductance measurements, magnetic susceptibility measurements, elemental analysis, and IR, 1H-NMR, 13C-NMR and electronic spectroscopy. Both Schiff base ligands were found to have a mono-anionic bidentate nature and octahedral geometry was assigned to all metal complexes. All the complexes contained coordinated water which was lost at 141–160 °C. These compounds were also screened for their in vitro antibacterial activity against four bacterial species, namely: Escherichia coli, Staphylococcus aureus, Salmonella typhi and Bacillus subtilis. The metal complexes were found to have greater antibacterial activity than the uncomplexed Schiff base ligands.

  2. Effects of Watering and Nitrogen Fertilization on Yield and Water and Nitrogen Use Efficiency of Cropping Oil Sunflower

    Directory of Open Access Journals (Sweden)

    TAN Jian-xin

    2015-10-01

    Full Text Available The field experiment with split-plot design was conducted to study the effects of the interaction of water and nitrogen fertilization on the growth and yield of oil sunflower, water and nitrogen use efficiency of cropping oil sunflower. This experiment set three irrigation rate treatments, including high irrigation treatment (5 250 m3·hm-2, middle irrigation treatment (3 750 m3·hm-2, low irrigation treatment (2 250 m3·hm-2, and four nitrogen application rate treatments, covering no nitrogen fertilization treatment (0 kg·hm-2, low nitrogen application treatment (120 kg·hm-2, middle nitrogen application treatment (240 kg·hm-2 and high nitrogen application treatment (360 kg·hm-2. The results showed that the nitrogen absorption and nitrogen use efficiency of cropping oil sunflower increased as the irrigation rate increased. With the nitrogen application rate increased, the yield of cropping oil sunflower was increased when the nitrogen application rate was 0~240 kg·hm-2, but beyond the 240 kg·hm-2, there was no significant increase. With the irrigation rate increased, the water consumption amount of cropping oil sunflower increased all the time, but the water use efficiency increased first, and hen decreased. Besides there was no significant difference between 240 kg·hm-2 and 360 kg·hm-2 treatment. Under our experiment condition, during the cropping oil sunflower growth period, when the irrigation rate was 5 250 m3·hm-2 (high irrigation rate and the nitrogen ertilization was 360 m3·hm-2 (high nitrogen application rate, the yield of cropping oil sunflower was 3 598 kg·hm-2. When the irrigation rate was 3 750 m3·hm-2 (middle irrigation rate and the nitrogen fertilization was 240 m3·hm-2 (middle nitrogen application rate, the yield was 3 518 kg·hm-2, with the yield components similar with the high irrigation rate and high nitrogen application rate treatment. Considering various factors, middle irrigation rate and middle nitrogen

  3. Future Prospects for the Total Artificial Heart.

    Science.gov (United States)

    Sunagawa, Gengo; Horvath, David J; Karimov, Jamshid H; Moazami, Nader; Fukamachi, Kiyotaka

    2016-01-01

    A total artificial heart (TAH) is the sole remaining option for patients with biventricular failure who cannot be rescued by left ventricular assist devices (LVADs) alone. However, the pulsatile TAH in clinical use today has limitations: large pump size, unknown durability, required complex anticoagulation regimen, and association with significant postsurgical complications. That pump is noisy; its large pneumatic driving lines traverse the body, with bulky external components for its drivers. Continuous-flow pumps, which caused a paradigm shift in the LVAD field, have already contributed to the rapidly evolving development of TAHs. Novel continuous-flow TAHs are only in preclinical testing or developmental stages. We here review the current state of TAHs, with recommended requirements for the TAH of the future.

  4. SEPARATION OF Fe (III, Cr(III, Cu(II, Ni(II, Co(II, AND Pb(II METAL IONS USING POLY(EUGENYL OXYACETIC ACID AS AN ION CARRIER BY A LIQUID MEMBRANE TRANSPORT METHOD

    Directory of Open Access Journals (Sweden)

    La Harimu

    2010-06-01

    Full Text Available Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II  metal ions had been separated using poly(eugenyl oxyacetic acid as an ion carrier by bulk liquid membrane transport method. The effect of pH, polyeugenyl oxyacetic acid ion carrier concentration, nitric acid concentration in the stripping solution, transport time, and metal concentration were optimized. The result showed that the optimum condition for transport of metal ions was at pH 4 for ion Fe(III and at pH 5 for Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions. The carrier volumes were optimum with concentration of 1 x 10-3 M at 7.5 mL for Cr(III, Cu (II,  Ni(II, Co(II ions and at 8.5 mL for Fe(III and Pb(II ions. The concentration of HNO3 in stripping phase was optimum at 2 M for Fe(III and Cu(II ions, 1 M for Cr(III, Ni(II and Co(II ions, and 0.5 M for Pb(II ion. The optimum transport times were 36 h for Fe(III and Co(II ions, and 48 h for Cr(III, Cu (II, Ni(II, and Pb(II ions. The concentration of metal ions accurately transported were 2.5 x 10-4 M for Fe(III and Cr(III ions, and 1 M for Cu (II, Ni(II, Co(II, and Pb(II ions. Compared to other metal ions the transport of Fe(III was the highest with selectivity order of Fe(III > Cr(III > Pb(II > Cu(II > Ni(II > Co(II. At optimum condition, Fe(III ion was transported through the membrane at 46.46%.   Keywords: poly(eugenyl oxyacetic acid, transport, liquid membrane, Fe (III, Cr(III, Cu(II, Ni(II, Co(II, and Pb(II ions

  5. Synthesis and Characterization of Multimetallic Fe(II) and Mn(II ...

    African Journals Online (AJOL)

    Iron(II) and Manganese(II) complexes of the resulting ligand were obtained from its reactions with Fe(II) and Mn(II) salts in absolute methanol for the metal to ligand ratio 2:3. These complexes were characterized by Solubility, Conductivity, IR and UV-VIS spectrometry, elemental analysis and mass spectrometry. Keywords: ...

  6. (II) complexes

    African Journals Online (AJOL)

    activities of Schiff base tin (II) complexes. Neelofar1 ... Conclusion: All synthesized Schiff bases and their Tin (II) complexes showed high antimicrobial and ...... Singh HL. Synthesis and characterization of tin (II) complexes of fluorinated Schiff bases derived from amino acids. Spectrochim Acta Part A: Molec Biomolec.

  7. Clinical evaluation of 123I-metaiodobenzylguanidine myocardial scintigram in patients with vascular heart disease

    International Nuclear Information System (INIS)

    Terada, Kouji; Sugihara, Hiroki; Shiga, Koji

    1995-01-01

    Myocardial sympathetic nerve function can be evaluated by 123 I-metaiodobenzylguanidine (MIBG) scintigraphy. Congestive heart failure is closely related to myocardial sympathetic nerve function. This study evaluated the severity of congestive heart failure in 30 patients with valvular heart disease [aortic regurgitation (AR): n=20, mean age=70±13 years; mitral regurgitation (MR): n=10, mean age=61±18 years], who had chronic heart failure by MIBG myocardial scintigraphy. Single photon emission computed tomography (SPECT) and anterior planar myocardial images were obtained 15 minutes (initial images) and 4 hours (delayed images) after injection of MIBG (111 MBq). Defect score was determined by the delayed SPECT images visually as a semi-quantitative index. Myocardial MIBG uptake was quantified by the heart to upper mediastinum uptake ratio on the delayed anterior planar images (H/M) and mean cardiac MIBG washout rate during 4 hours was calculated from the bull's eye display data (clearance). These indices were compared with the NYHA class and echocardiographic findings of the patients. MIBG regional defect in the delayed image was most frequently seen in the inferoposterior wall, and defect score and clearance were significantly higher and the H/M ratio was significantly lower in NYHA class III patients than in class II patients. In patients with AR, clearance significantly correlated with left ventricular end-systolic dimension. In patients with MR, both the H/M ratio and clearance significantly correlated with left atrial dimension. Defect score, H/M, and clearance were closely related to the severity of AR and MR. These results indicate that MIBG scan can be used to assess the severity of valvular heart disease. (author)

  8. Clinical evaluation of {sup 123}I-metaiodobenzylguanidine myocardial scintigram in patients with vascular heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Terada, Kouji; Sugihara, Hiroki; Shiga, Koji [Kyoto Prefectural Univ. of Medicine (Japan)] [and others

    1995-05-01

    Myocardial sympathetic nerve function can be evaluated by {sup 123}I-metaiodobenzylguanidine (MIBG) scintigraphy. Congestive heart failure is closely related to myocardial sympathetic nerve function. This study evaluated the severity of congestive heart failure in 30 patients with valvular heart disease [aortic regurgitation (AR): n=20, mean age=70{+-}13 years; mitral regurgitation (MR): n=10, mean age=61{+-}18 years], who had chronic heart failure by MIBG myocardial scintigraphy. Single photon emission computed tomography (SPECT) and anterior planar myocardial images were obtained 15 minutes (initial images) and 4 hours (delayed images) after injection of MIBG (111 MBq). Defect score was determined by the delayed SPECT images visually as a semi-quantitative index. Myocardial MIBG uptake was quantified by the heart to upper mediastinum uptake ratio on the delayed anterior planar images (H/M) and mean cardiac MIBG washout rate during 4 hours was calculated from the bull`s eye display data (clearance). These indices were compared with the NYHA class and echocardiographic findings of the patients. MIBG regional defect in the delayed image was most frequently seen in the inferoposterior wall, and defect score and clearance were significantly higher and the H/M ratio was significantly lower in NYHA class III patients than in class II patients. In patients with AR, clearance significantly correlated with left ventricular end-systolic dimension. In patients with MR, both the H/M ratio and clearance significantly correlated with left atrial dimension. Defect score, H/M, and clearance were closely related to the severity of AR and MR. These results indicate that MIBG scan can be used to assess the severity of valvular heart disease. (author).

  9. Fe (III), Co(II), Ni(II), Cu(II) and Zn(II) complexes of schiff bases based-on glycine and phenylalanine: Synthesis, magnetic/thermal properties and antimicrobial activity

    Science.gov (United States)

    Sevgi, Fatih; Bagkesici, Ugur; Kursunlu, Ahmed Nuri; Guler, Ersin

    2018-02-01

    Zinc (II), copper (II), nickel (II), cobalt (II) and iron (III) complexes of Schiff bases (LG, LP) derived from 2-hydroxynaphthaldehyde with glycine and phenylalanine were reported and characterized by 1H NMR, 13C NMR, elemental analyses, melting point, FT-IR, magnetic susceptibility and thermal analyses (TGA). TGA data show that iron and cobalt include to the coordinated water and metal:ligand ratio is 1:2 while the complex stoichiometry for Ni (II), Cu (II) and Zn (II) complexes is 1:1. As expected, Ni (II) and Zn (II) complexes are diamagnetic; Cu (II), Co (II) and Fe (III) complexes are paramagnetic character due to a strong ligand of LG and LP. The LG, LP and their metal complexes were screened for their antimicrobial activities against five Gram-positive (Staphylococcus aureus, Methicillin resistant Staphylococcus aureus (MRSA), Bacillus cereus, Streptococcus mutans and Enterococcus faecalis) and three Gram-negative (Escherichia coli, Klebsiella pneumoniae and Pseudomonas aeruginosa) and one fungi (Candida albicans) by using broth microdilution techniques. The activity data show that ligands and their metal complexes exhibited moderate to good activity against Gram-positive bacteria and fungi.

  10. DNA damage by the cobalt (II) and zinc (II) complexes of ...

    African Journals Online (AJOL)

    Using the single cell gel electrophoresis method, the tetraazamacrocycle Zn(II) complex (Zn(II)-L) and the tetraazamacrocycle Co(II) complex (Co(II)-L) were investigated focusing on their DNA damage to Tetrahymena thermophila. When the cells were treated with the 0.05, 0.25 and 0.50 mg/ml Zn(II)-L, the tail length ...

  11. Syntheses and spectroscopic properties of mercury(II) and nickel(II ...

    African Journals Online (AJOL)

    Mercury(II) complex, [Hg2(BPTU-2H)Cl2] and nickel(II) complex, [Ni(BPTU-H)2] were prepared by reacting Bis(N-phenylthiourea), BPTU, with mercury(II) chloride and nickel(II) acetate respectively. The complexes were characterized by IR, diffuse reflectance, 1H NMR spectra and elemental analysis. BPTU acts as ...

  12. Solar Type II Radio Bursts and IP Type II Events

    Science.gov (United States)

    Cane, H. V.; Erickson, W. C.

    2005-01-01

    We have examined radio data from the WAVES experiment on the Wind spacecraft in conjunction with ground-based data in order to investigate the relationship between the shocks responsible for metric type II radio bursts and the shocks in front of coronal mass ejections (CMEs). The bow shocks of fast, large CMEs are strong interplanetary (IP) shocks, and the associated radio emissions often consist of single broad bands starting below approx. 4 MHz; such emissions were previously called IP type II events. In contrast, metric type II bursts are usually narrowbanded and display two harmonically related bands. In addition to displaying complete dynamic spectra for a number of events, we also analyze the 135 WAVES 1 - 14 MHz slow-drift time periods in 2001-2003. We find that most of the periods contain multiple phenomena, which we divide into three groups: metric type II extensions, IP type II events, and blobs and bands. About half of the WAVES listings include probable extensions of metric type II radio bursts, but in more than half of these events, there were also other slow-drift features. In the 3 yr study period, there were 31 IP type II events; these were associated with the very fastest CMEs. The most common form of activity in the WAVES events, blobs and bands in the frequency range between 1 and 8 MHz, fall below an envelope consistent with the early signatures of an IP type II event. However, most of this activity lasts only a few tens of minutes, whereas IP type II events last for many hours. In this study we find many examples in the radio data of two shock-like phenomena with different characteristics that occur simultaneously in the metric and decametric/hectometric bands, and no clear example of a metric type II burst that extends continuously down in frequency to become an IP type II event. The simplest interpretation is that metric type II bursts, unlike IP type II events, are not caused by shocks driven in front of CMEs.

  13. Fate of nitrogen in soil-crop system by nuclear techniques. Effects of applied rate of ammonium bicarbonate

    International Nuclear Information System (INIS)

    Chen Qing

    1996-11-01

    The experiment was conducted with 15 N tracing techniques in Shijiazhuang from 1994 to 1995. Three nitrogen rates, including optimum rate (150 kg/hm 2 ) based on the recommendation of local farmers, above 50% of optimum rate (225 kg/hm 2 ) and below 50% of optimum rate (75 kg/hm 2 ), were selected to study the effect of application rates of ammonium bicarbonate on yield of winter wheat and fate of applied nitrogen under local management and irrigated condition. The results showed that nitrogen uptake and grain yield of wheat under fertilized treatments were higher than those in unfertilized treatment (except 225 kg/hm 2 treatment). The highest yield and top dry mater weight (grain 6.80 t/hm 2 , top 14.70 t/hm 2 ) were obtained in optimum N applied treatment (150 kg/hm 2 ), while the highest nitrogen recovery efficiency (38.5%) of ammonium bicarbonate by winter wheat was found in below 50% of optimum rate treatment (75 kg/hm 2 ) due to the relatively high basic fertility of the field. However, nitrogen recovery efficiency of ammonium bicarbonate decreased with the increasing N application rate. The highest residue of fertilizer N was found in 225 kg/hm 2 treatment, and 46% of the residue existed in the top layer of the soil (0∼50 cm). The unaccounted N from fertilizer were 30.20%, 36.56%, 31.25% in 75 kg/hm 2 , 150 kg/hm 2 , 225 kg/hm 2 treatments respectively according to 15 N balance calculation in soil-plant system. The effect of residue N in soil on the next crop, maize, in 225 kg/hm 2 treatment was best in three fertilized treatments, suggesting the possibilities of nitrate leaching down in 225 kg/hm 2 treatment. (15 tabs.)

  14. Yeast cell wall extract induces disease resistance against bacterial and fungal pathogens in Arabidopsis thaliana and Brassica crop.

    Directory of Open Access Journals (Sweden)

    Mari Narusaka

    Full Text Available Housaku Monogatari (HM is a plant activator prepared from a yeast cell wall extract. We examined the efficacy of HM application and observed that HM treatment increased the resistance of Arabidopsis thaliana and Brassica rapa leaves to bacterial and fungal infections. HM reduced the severity of bacterial leaf spot and anthracnose on A. thaliana and Brassica crop leaves with protective effects. In addition, gene expression analysis of A. thaliana plants after treatment with HM indicated increased expression of several plant defense-related genes. HM treatment appears to induce early activation of jasmonate/ethylene and late activation of salicylic acid (SA pathways. Analysis using signaling mutants revealed that HM required SA accumulation and SA signaling to facilitate resistance to the bacterial pathogen Pseudomonas syringae pv. maculicola and the fungal pathogen Colletotrichum higginsianum. In addition, HM-induced resistance conferred chitin-independent disease resistance to bacterial pathogens in A. thaliana. These results suggest that HM contains multiple microbe-associated molecular patterns that activate defense responses in plants. These findings suggest that the application of HM is a useful tool that may facilitate new disease control methods.

  15. Synthesis and characterization of iron(III), manganese(II), cobalt(II), nickel(II), copper(II) and zinc(II) complexes of salicylidene-N-anilinoacetohydrazone (H2L1) and 2-hydroxy-1-naphthylidene-N-anilinoacetohydrazone (H2L2).

    Science.gov (United States)

    AbouEl-Enein, S A; El-Saied, F A; Kasher, T I; El-Wardany, A H

    2007-07-01

    Salicylidene-N-anilinoacetohydrazone (H(2)L(1)) and 2-hydroxy-1-naphthylidene-N-anilinoacetohydrazone (H(2)L(2)) and their iron(III), manganese(II), cobalt(II), nickel(II), copper(II) and zinc(II) complexes have been synthesized and characterized by IR, electronic spectra, molar conductivities, magnetic susceptibilities and ESR. Mononuclear complexes are formed with molar ratios of 1:1, 1:2 and 1:3 (M:L). The IR studies reveal various modes of chelation. The electronic absorption spectra and magnetic susceptibility measurements show that the iron(III), nickel(II) and cobalt(II) complexes of H(2)L(1) have octahedral geometry. While the cobalt(II) complexes of H(2)L(2) were separated as tetrahedral structure. The copper(II) complexes have square planar stereochemistry. The ESR parameters of the copper(II) complexes at room temperature were calculated. The g values for copper(II) complexes proved that the Cu-O and Cu-N bonds are of high covalency.

  16. Tinjauan Kriminologis Tentang Kejahatan Pencurian Kendaraan Bermotor (Studi Kasus Di Kota Makassar Pada Tahun 2007-2011)

    OpenAIRE

    Ramadani, Neny Riski

    2012-01-01

    ABSTRAK NENY RISKI RAMADANI (B111 08 305), ???Tinjauan Kriminologis Tentang Kejahatan Pencurian Kendaraan Bermotor (Studi Kasus Di Kota Makassar Pada Tahun 2007-2011) ??? di bawah bimbingan Bapak H.M. Imran Arief, sebagai pembimbing I dan Ibu Hj. Nur Azisa, sebagai pembimbing II. Penelitian ini bertujuan untuk mengetahui faktor-faktor apa saja yang menyebabkan terjadinya pencurian kendaraan bermotor di kota Makassar dalam kurun waktu lima tahun terakhir, serta untuk mengetahui upaya-up...

  17. Pecan nutshell as biosorbent to remove Cu(II), Mn(II) and Pb(II) from aqueous solutions.

    Science.gov (United States)

    Vaghetti, Julio C P; Lima, Eder C; Royer, Betina; da Cunha, Bruna M; Cardoso, Natali F; Brasil, Jorge L; Dias, Silvio L P

    2009-02-15

    In the present study we reported for the first time the feasibility of pecan nutshell (PNS, Carya illinoensis) as an alternative biosorbent to remove Cu(II), Mn(II) and Pb(II) metallic ions from aqueous solutions. The ability of PNS to remove the metallic ions was investigated by using batch biosorption procedure. The effects such as, pH, biosorbent dosage on the adsorption capacities of PNS were studied. Four kinetic models were tested, being the adsorption kinetics better fitted to fractionary-order kinetic model. Besides that, the kinetic data were also fitted to intra-particle diffusion model, presenting three linear regions, indicating that the kinetics of adsorption should follow multiple sorption rates. The equilibrium data were fitted to Langmuir, Freundlich, Sips and Redlich-Peterson isotherm models. Taking into account a statistical error function, the data were best fitted to Sips isotherm model. The maximum biosorption capacities of PNS were 1.35, 1.78 and 0.946mmolg(-1) for Cu(II), Mn(II) and Pb(II), respectively.

  18. Physico - chemical investigation on Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO2+2 and VO+2 ions-O-(-N-3,5-dichloro-α-pyridone imino)

    International Nuclear Information System (INIS)

    Mathur, Praveen; Trivedi, Pradeep; Mehta, R.K.

    1983-01-01

    Studies on the interaction of newly synthesised ligand, O-(N-3, 5-dichloro-α-pyridone imino) benzene sulphonic acid (H 2 PB) with Co(II), Ni(II), Cu(II), Zn(II), Cd(II), UO 2 +2 and VO +2 have been carried out potentiometrically. Many physico-chemical studies on thermodynamics, elemental analysis, molecular weight, magnetic moment, conductance, electronic and IR spectra have also been made on the solid chelates and their adducts. The dissociation constants of H 2 PB and stabilities of its bivalent chelates have been evaluated potentiometrically at 25deg, 35deg and 45degC in aqueous medium (0.01M, 0.05M and 0.1M NaClO 4 ) by Bjerrum's method. The stability sequence is in agreement with the Irving-William's rule. (author)

  19. Unsaturated b-ketoesters and their Ni(II, Cu(II and Zn(II complexes

    Directory of Open Access Journals (Sweden)

    MUHAMMED BASHEER UMMATHUR

    2009-03-01

    Full Text Available A new series of b-ketoesters in which the keto group is attached to the olefinic linkage were synthesized by the reaction of methyl acetoacetate and aromatic aldehydes under specified conditions. The existence of these compounds predominantly in the intramolecularly hydrogen bonded enol form was well demonstrated from their IR, 1H-NMR and mass spectral data. Details on the formation of their [ML2] complexes with Ni(II, Cu(II and Zn(II and the nature of the bonding are discussed on the basis of analytical and spectral data.

  20. Synthesis, spectral, thermal and antimicrobial studies on cobalt(II), nickel(II), copper(II), zinc(II) and palladium(II) complexes containing thiosemicarbazone ligand

    Science.gov (United States)

    El-Sawaf, Ayman K.; El-Essawy, Farag; Nassar, Amal A.; El-Samanody, El-Sayed A.

    2018-04-01

    The coordination characteristic of new N4-morpholinyl isatin-3-thiosemicarbazone (HL) towards Co(II), Ni(II), Cu(II), Zn(II) and Pd(II) has been studies. The structures of the complexes were described by elemental analyses, molar conductivity, magnetic, thermal and spectral (IR, UV-Vis, 1H and 13C NMR and ESR) studies. On the basis of analytical and spectral studies the ligand behaves as monobasic tridentate ONS donor forming two five membered rings towards cobalt, copper and palladium and afforded complexes of the kind [M(L)X], (Mdbnd Co, Cu or Pd; Xdbnd Cl, Br or OAc). Whereas the ligand bound to NiCl2 as neutral tridentate ONS donor and with ZnCl2 as neutral bidentate NS donor. The newly synthesized thiosemicarbazone ligand and some of its complexes were examined for antimicrobial activity against 2 gram negative bacterial strains (Escherichia coli Pseudomonas and aeruginosa), 2 gram positive bacterial strains (Streptococcus pneumoniae and Staphylococcus aureus)} and two Pathogenic fungi (Aspergillus fumigatus and Candida albicans). All metal complexes possess higher antimicrobial activity comparing with the free thiosemicarbazone ligand. The high potent activities of the complexes may arise from the coordination and chelation, which tends to make metal complexes act as more controlling and potent antimicrobial agents, thus hindering the growing of the microorganisms. The antimicrobial results also show that copper bromide complex is better antimicrobial agent as compared to the Schiff base and its metal complexes.

  1. Distribution and features of hematological malignancies in Eastern Morocco: a retrospective multicenter study over 5 years.

    Science.gov (United States)

    Elidrissi Errahhali, Mounia; Elidrissi Errahhali, Manal; Boulouiz, Redouane; Ouarzane, Meryem; Bellaoui, Mohammed

    2016-02-25

    Hematological malignancies (HM) are a public health problem. The pattern and distribution of diagnosed hematological cancers vary depending on age, sex, geography, and ethnicity suggesting the involvement of genetic and environmental factors for the development of these diseases. To our knowledge, there is no published report on HM in the case of Eastern Morocco. In this report we present for the first time the overall pattern of HM for this region. Retrospective descriptive study of patients diagnosed with HM between January 2008 and December 2012 in three centres in Eastern Morocco providing cancer diagnosis, treatment or palliative care services. The FAB (French-American-British) classification system has been taken into account in the analysis of myeloid and lymphoid neoplasms. In this study, a total of 660 cases of HM were registered between January 2008 and December 2012. Overall, 6075 cases of cancers all sites combined were registered during this study period, indicating that HM account for around 10.9 % (660/6075) of all cancers recorded. Among the 660 registered cases of HM, 53 % were males and 47 % were females, with a male to female ratio of 1.1. Thus, overall, men are slightly more affected with HM than women. By contrast, a female predominance was observed in the case of Hodgkin's lymphoma (HL), myeloproliferative neoplasms (MPN), acute myeloid leukemia (AML) and the myelodysplastic syndrome (MDS). HM occur at a relatively young age, with an overall median age at diagnosis of 54 years. Non-Hodgkin's lymphoma (NHL) was the most common HM accounting for 29.7 % of all HM, followed by HL, MPN, multiple myelomas (MM), chronic lymphocytic leukemia (CLL), AML, MDS, acute lymphoblastic leukemia (ALL), and Waldenström macroglobulinemia (WM). The majority of HM cases have been observed among patients aged 60 years and over (40.4 % of HM). Among this age group, NHL was the most common HM. In adolescents, HL was the most frequent HM. This study provided for the

  2. Equilibrium and kinetic studies of Pb(II, Cd(II and Zn(II sorption by Lagenaria vulgaris shell

    Directory of Open Access Journals (Sweden)

    Mitić-Stojanović Dragana-Linda

    2012-01-01

    Full Text Available The sorption of lead, cadmium and zinc ions from aqueous solution by Lagenaria vulgaris shell biosorbent (LVB in batch system was investigated. The effect of relevant parameters such as contact time, biosorbent dosage and initial metal ions concentration was evaluated. The Pb(II, Cd(II and Zn(II sorption equilibrium (when 98% of initial metal ions were sorbed was attained within 15, 20 and 25 min, respectively. The pseudo first, pseudo-second order, Chrastil’s and intra-particle diffusion models were used to describe the kinetic data. The experimental data fitted the pseudo-second order kinetic model and intra-particle diffusion model. Removal efficiency of lead(II, cadmium(II and zinc(II ions rapidly increased with increasing biosorbent dose from 0.5 to 8.0 g dm-3. Optimal biosorbent dose was set to 4.0 g dm-3. An increase in the initial metal concentration increases the sorption capacity. The sorption data of investigated metal ions are fitted to Langmuir, Freundlich and Temkin isotherm models. Langmuir model best fitted the equilibrium data (r2 > 0.99. Maximal sorption capacities of LVB for Pb(II, Cd(II and Zn(II at 25.0±0.5°C were 0.130, 0.103 and 0.098 mM g-1, respectively. The desorption experiments showed that the LVB could be reused for six cycles with a minimum loss of the initial sorption capacity.

  3. Recovery of Cd(II), Co(II) and Ni(II) from Chloride Medium by Solvent Extraction Using CYANEX 923 and CYANEX 272 I

    International Nuclear Information System (INIS)

    Ahmed, M.; El Dessouky, S.I.; El-Nadi, Y.A.; Daoud, J.A.; Saad, E.A.

    2008-01-01

    The paper aims to study the extraction and separation of Cd(II), Co(II) and Ni(II) from their mixtures in hydrochloric acid medium with CYANEX 923 in kerosene. Preliminary investigations showed that only Cd(II) is extracted with CYANEX 923 while Co(II) and Ni(II) are not extracted. Different parameters affecting the extraction of Cd(II) with CYANEX 923 such as hydrochloric acid, hydrogen ion, extractant and metal concentrations, temperature investigations were also investigated. The stoichiometry of the extracted metal species investigated was found to be HCdCl 3 . 2 CYANEX 923. The stripping of the extracted Cd(II) species is obtained with 0.1 M HCl solution. Co(II) was found to be extracted with CYANEX 272 at ph 5.8 leaving Ni(II) in the solution. A developed process for the sequential of Cd(II), Co(II) and Ni(II) from their mixture in hydrochloric acid medium is proposed

  4. Performance of Noninvasive Assessment in the Diagnosis of Right Heart Failure After Left Ventricular Assist Device.

    Science.gov (United States)

    Joly, Joanna M; El-Dabh, Ashraf; Marshell, Ramey; Chatterjee, Arka; Smith, Michelle G; Tresler, Margaret; Kirklin, James K; Acharya, Deepak; Rajapreyar, Indranee N; Tallaj, José A; Pamboukian, Salpy V

    2018-06-01

    Right heart failure (RHF) after left ventricular assist device (LVAD) is associated with poor outcomes. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) defines RHF as elevated right atrial pressure (RAP) plus venous congestion. The purpose of this study was to examine the diagnostic performance of the noninvasive INTERMACS criteria using RAP as the gold standard. We analyzed 108 patients with LVAD who underwent 341 right heart catheterizations (RHC) between January 1, 2006, and December 31, 2013. Physical exam, echocardiography, and laboratory data at the time of RHC were collected. Conventional two-by-two tables were used and missing data were excluded. The noninvasive INTERMACS definition of RHF is 32% sensitive (95% CI, 0.21-0.44) and 97% specific (95% CI, 0.95-0.99) for identifying elevated RAP. Clinical assessment failed to identify two-thirds of LVAD patients with RAP > 16 mm Hg. More than half of patients with elevated RAP did not have venous congestion, which may represent a physiologic opportunity to mitigate the progression of disease before end-organ damage occurs. One-quarter of patients who met the noninvasive definition of RHF did not actually have elevated RAP, potentially exposing patients to unnecessary therapies. In practice, if any component of the INTERMACS definition is present or equivocal, our data suggest RHC is warranted to establish the diagnosis.

  5. Trends in the Management of Patients With Left Ventricular Assist Devices Presenting for Noncardiac Surgery: A 10-Year Institutional Experience.

    Science.gov (United States)

    Stone, Marc; Hinchey, Joseph; Sattler, Christopher; Evans, Adam

    2016-09-01

    In our institution, the vast majority of patients presenting for noncardiac surgery (NCS) while supported by a left ventricular assist device (LVAD) are now cared for by noncardiac-trained anesthesiologists as the result of a decade of educational intervention to effect this transition. This represents a significant departure from the published experiences of other institutions. With institutional review board approval, we queried the database of our anesthesia record keeping system (CompuRecord) to determine various aspects of the perioperative management of these patients from July 1, 2003, through June 30, 2013, during which time 271 NCS procedures were performed on adult patients supported by LVADs. Over the entire study period (2003-2013), anesthetic care was provided by a cardiac anesthesiologist 47% of the time and by a noncardiac anesthesiologist 53% of the time. However, by the time period 2012-2013, 88% of the NCS procedures were staffed by a noncardiac anesthesiologist. Despite the prevalence of continuous flow devices in this series, the use of invasive blood pressure monitoring decreased dramatically by the later years of the study. Vasoactive and inotropic medications were rarely required intraoperatively. No intraoperative cardiac arrests, thromboembolic complications, or device malfunctions occurred. Our conclusion is that NCS procedures on LVAD-supported patients can be safely managed by educated noncardiac anesthesiologists. © The Author(s) 2015.

  6. The type II collagen fragments Helix-II and CTX-II reveal different enzymatic pathways of human cartilage collagen degradation

    DEFF Research Database (Denmark)

    Charni-Ben Tabassi, N; Desmarais, S; Jensen, Anne-Christine Bay

    2008-01-01

    human recombinant cathepsins (Cats) and matrix-metalloproteases (MMPs). Next, we analyzed the spontaneous release of Helix-II and CTX-II from cartilage sections of patients with knee OA who were immediately deep frozen after joint replacement to preserve endogenous enzyme activity until assay. Cartilage....... Cat D was unable to digest intact cartilage. MMPs-1, -3, -7, -9, and -13 efficiently released CTX-II, but only small amount of Helix-II. Neither CTX-II nor Helix-II alone was able to reflect accurately the collagenolytic activity of Cats and MMPs as reflected by the release of hydroxyproline. In OA...

  7. Thermal, spectral, magnetic and biological studies of thiosemicarbazones complexes with metal ions: Cu(II), Co(II), Ni(II), Fe(III), Zn(II), Mn(II) and UO2(VI)

    International Nuclear Information System (INIS)

    Mashaly, M.M.; Seleem, H.S.; El-Behairy, M.A.; Habib, H.A.

    2004-01-01

    Thiosemicarbazones ligands, isatin-3-thiosemicarbazone(HIT) and N-acetylisatin-3-thiosemicarbazone (HAIT), which have tridentate ONN coordinating sites were prepared. The complexes of both ligands with Cu(II), Co(II), Ni(II), Fe(III), Zn(II), Mn(II) and UO 2 (VI) ions were isolated. The ligands and their metal complexes were characterized by elemental analysis, IR, UV-Vis and mass spectra, also by conductance, magnetic moment and TG-DSC measurements. All the transition metal complexes have octahedral configurations, except Cu-complexes which have planar geometry and the UO 2 (VI) complexes which have coordination number 8 and may acquire the distorted dodecahedral geometry. Thermal studies explored the possibility of obtaining new complexes. Inversion from octahedral to square-planar configuration occurred upon heating the parent Ni-HIAT complex to form the corresponding pyrolytic product. The antifungal activity against the tested organisms showed that some metal complexes enhanced the activity with respect to the parent ligands. (author)

  8. Competitive adsorption of Pb(II), Cu(II), and Zn(II) ions onto hydroxyapatite-biochar nanocomposite in aqueous solutions

    Science.gov (United States)

    Wang, Yu-Ying; Liu, Yu-Xue; Lu, Hao-Hao; Yang, Rui-Qin; Yang, Sheng-Mao

    2018-05-01

    A hydroxyapatite-biochar nanocomposite (HAP-BC) was successfully fabricated and its physicochemical properties characterized. The analyses showed that HAP nanoparticles were successfully loaded on the biochar surface. The adsorption of Pb(II), Cu(II), and Zn(II) by HAP-BC was systematically studied in single and ternary metal systems. The results demonstrated that pH affects the adsorption of heavy metals onto HAP-BC. Regarding the adsorption kinetics, the pseudo-second-order model showed the best fit for all three heavy metal ions on HAP-BC. In both single and ternary metal ion systems, the adsorption isotherm of Pb(II) by HAP-BC followed Langmuir model, while those of Cu(II) and Zn(II) fitted well with Freundlich model. The maximum adsorption capacity for each tested metal by HAP-BC was higher than that of pristine rice straw biochar (especially for Pb(II)) or those of other reported adsorbents. Therefore, HAP-BC could explore as a new material for future application in heavy metal removal.

  9. Biosorption characteristics of copper (II), chromium (III), nickel (II), and lead (II) from aqueous solutions by Chara sp. and Cladophora sp.

    Science.gov (United States)

    Elmaci, Ayşe; Yonar, Taner; Ozengin, Nihan

    2007-09-01

    The aim of this research was to expose individual removals of copper, chromium, nickel, and lead from aqueous solutions via biosorption using nonliving algae species, Chara sp. and Cladophora sp. Optimum pH values for biosorption of copper (II), chromium (III), nickel (II), and lead (II) from aqueous solutions were determined to be 6, 7, 7, and 3 for Cladophora sp. and 5, 3, 5, and 4 for Chara sp. respectively. Maximum adsorption capacities of Chara sp. [10.54 for chromium (III) and 61.72 for lead (II)] and Cladophora sp. [6.59 for chromium (III) and 16.75 and 23.25 for lead (II)] for chromium (III) and lead (II) are similar. On the other hand, copper (II) and nickel (II) biosorption capacity of Cladophora sp. [14.28 for copper (II) and 16.75 for nickel (II)] is greater than Chara sp. [6.506 for copper (II) and 11.76 for nickel (II)]. Significantly high correlation coefficients indicated for the Langmuir adsorption isotherm models can be used to describe the equilibrium behavior of copper, chromium, nickel, and lead adsorption onto Cladophora sp. and Chara sp.

  10. DNA damage by the cobalt (II) and zinc (II) complexes of ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-09-03

    Sep 3, 2008 ... distributed in grade 3. The results indicated that Co(II)-L induced a relatively high level of DNA damage in comparison with the level of damage induced by Zn(II)-L. Key words: Tetraazamacrocycle Zn(II) complex, tetraazamacrocycle Co(II) complex, Tetrahymena thermophila, DNA damage, the comet assay.

  11. Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach.

    Science.gov (United States)

    Stevens, Michael C; Wilson, Stephen; Bradley, Andrew; Fraser, John; Timms, Daniel

    2014-09-01

    Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow

  12. Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency.

    Science.gov (United States)

    Fine, Nowell M; Park, Soon J; Stulak, John M; Topilsky, Yan; Daly, Richard C; Joyce, Lyle D; Pereira, Naveen L; Schirger, John A; Edwards, Brooks S; Lin, Grace; Kushwaha, Sudhir S

    2016-04-01

    In this study we examined the impact of continuous-flow left ventricular assist device (CF-LVAD) support on proximal thoracic aorta dimensions. Aortic root and ascending aorta diameter were measured from serial echocardiograms before and after CF-LVAD implantation in patients with ≥6 months of support, and correlated with the development of >mild aortic valve insufficiency (AI). Of 162 patients included, mean age was 58 ± 11 years and 128 (79%) were male. Seventy-nine (63%) were destination therapy patients. Mean aortic root and ascending aorta diameters at baseline, 1 month, 6 months, 12 months and long-term follow-up (mean 2.0 ± 1.4 years) were 3.5 ± 0.4, 3.5 ± 0.3, 3.9 ± 0.3, 3.9 ± 0.2 and 4.0 ± 0.3, and 3.3 ± 0.2, 3.3 ± 0.3, 3.6 ± 0.2, 3.6 ± 0.3 and 3.6 ± 0.3 cm, respectively. Only change in aortic root diameter from 1-month to 6-month follow-up reached statistical significance (p = 0.03). Nine (6%) patients had accelerated proximal thoracic aorta expansion (>0.5 cm/year), occurring predominantly in the first 6 months after implantation. These patients were older and more likely to have hypertension and baseline proximal thoracic aorta dilation. Forty-five (28%) patients developed >mild AI at long-term follow-up, including 7 of 9 (78%) of those with accelerated proximal thoracic aorta expansion. All 7 had aortic valves that remained closed throughout the cardiac cycle, and this, along with duration of CF-LVAD support and increase in aortic root diameter, were significantly associated with developing >mild AI. CF-LVAD patients have small increases in proximal thoracic aorta dimensions that predominantly occur within the first 6 months after implantation and then stabilize. Increasing aortic root diameter was associated with AI development. Copyright © 2016 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  13. Synthesis and characterization of nickel(II), cobalt(II), copper(II), manganese(II), zinc(II), zirconium(IV), dioxouranium(VI) and dioxomolybdenum(VI) complexes of a new Schiff base derived from salicylaldehyde and 5-methylpyrazole-3-carbohydrazide

    International Nuclear Information System (INIS)

    Syamal, A.; Maurya, M.R.

    1986-01-01

    Synthesis of a new Schiff base derived from salicylaldehyde and 5-methylpyrazole-3-carbohydrazide, and its coordination compounds with nickel(II), cobalt(II), copper(II), manganese(II), zinc(II), zirconium(IV), dioxouranium(VI) and dioxomolybdenum(VI) are described. The ligand and the complexes have been characterized on the basis of analytical, conductance, molecular weight, i.r., electronic and n.m.r. spectra and magnetic susceptibility measurements. The stoichiometries of the complexes are represented as NiL . 3H 2 O, CoL . 2H 2 O, CuL, MnL . 2H 2 O, ZnL . H 2 O, Zr(OH) 2 (LH) 2 , Zr(OH) 2 L . 2MeOH, UO 2 L . MeOH and MoO 2 L . MeOH (where LH 2 =Schiff base). The copper(II) complex shows a subnormal magnetic moment due to antiferromagnetic exchange interaction while the nickel(II), cobalt(II) and manganese(II) complexes show normal magnetic moments at room temperature. The i.r. and n.m.r. spectral studies show that the Schiff base behaves as a dibasic and tridentate ligand coordinating through the deprotonated phenolic oxygen, enolic oxygen and azomethine nitrogen. (orig.)

  14. Levels of Cd (II, Mn (II, Pb (II, Cu (II, and Zn (II in Common Buzzard (Buteo buteo from Sicily (Italy by Derivative Stripping Potentiometry

    Directory of Open Access Journals (Sweden)

    P. Licata

    2010-01-01

    Full Text Available The purpose of this study was to determine the concentrations of heavy metals (Cd, Pb, Cu, Mn, and Zn in different organs (liver, kidney, muscle, lung, skin, and feathers of buzzards (Buteo buteo, utilized as a “biological indicator” for environmental contamination, from different areas of Sicily and to investigate the relationships between birds sex, age, and weight and metal levels in these samples. All samples of common buzzards were collected at the “Recovery Center of Wild Fauna” of Palermo, through the Zooprophilactic Institute. Potentiometric stripping analysis (PSA was used to determine the content of Cd(II, Cu(II, Mn(II, Pb(II, and Zn(II in bird tissues. For toxic metals, the highest levels of Pb were in liver and those of Cd in lung; Zn levels were higher than Cu and Mn in all tissues analyzed. The concentrations in liver, lung, kidney, and muscle could be considered as an indicative of chronic exposure to metals while the presence of metals in skin could be consequential to storing and elimination processes. The found concentrations of metals in the studied matrices required a highly sensitive method for their determination and a simple sample preparation procedure, and the proposed method was well suited for this purpose.

  15. Complexes cobalt(II, zinc(II and copper(II with some newly synthesized benzimidazole derivatives and their antibacterial activity

    Directory of Open Access Journals (Sweden)

    S. O. PODUNAVAC-KUZMANOVIC

    1999-05-01

    Full Text Available The preparation and properties of some complexes of cobalt(II, zinc(II and copper(II with several newly synthesized benzimidazole derivatives (L are reported. The complexes, of the general formula [MCl2L2] (M=Co(II, Zn(II and [CuCl2L(H2O], have a tetrahedral structure. The complexes were characterized by elemental analysis, molar conductivity, magnetic susceptibility measurements, IR and absorption electronic spectra. The antibacterial activitiy of the benzimidazoles and their complexes was evaluated against Erwinia carotovora subsp. carotovora and Erwinia amylovora. The complexes were found to be more toxic than the ligands.

  16. The anti-CMS technique for genome-wide mapping of 5-hydroxymethylcytosine.

    Science.gov (United States)

    Huang, Yun; Pastor, William A; Zepeda-Martínez, Jorge A; Rao, Anjana

    2012-10-01

    5-Hydroxymethylcytosine (5hmC) is a recently discovered base in the mammalian genome, produced upon oxidation of 5-methylcytosine (5mC) in a process catalyzed by TET proteins. The biological functions of 5hmC and further oxidation products of 5mC are under intense investigation, as they are likely intermediates in DNA demethylation pathways. Here we describe a novel protocol to profile 5hmC at a genome-wide scale. This approach is based on sodium bisulfite-mediated conversion of 5hmC to cytosine-5-methylenesulfonate (CMS); CMS-containing DNA fragments are then immunoprecipitated using a CMS-specific antiserum. The anti-CMS technique is highly specific with a low background, and is much less dependent on 5hmC density than anti-5hmC immunoprecipitation (IP). Moreover, it does not enrich for CA and CT repeats, as noted for 5hmC DNA IP using antibodies to 5hmC. The anti-CMS protocol takes 3 d to complete.

  17. 5-Hydroxymethylcytosine is a predominantly stable DNA modification

    Science.gov (United States)

    Bachman, Martin; Uribe-Lewis, Santiago; Yang, Xiaoping; Williams, Michael; Murrell, Adele; Balasubramanian, Shankar

    2014-12-01

    5-Hydroxymethylcytosine (hmC) is an oxidation product of 5-methylcytosine which is present in the deoxyribonucleic acid (DNA) of most mammalian cells. Reduction of hmC levels in DNA is a hallmark of cancers. Elucidating the dynamics of this oxidation reaction and the lifetime of hmC in DNA is fundamental to understanding hmC function. Using stable isotope labelling of cytosine derivatives in the DNA of mammalian cells and ultrasensitive tandem liquid-chromatography mass spectrometry, we show that the majority of hmC is a stable modification, as opposed to a transient intermediate. In contrast with DNA methylation, which occurs immediately during replication, hmC forms slowly during the first 30 hours following DNA synthesis. Isotopic labelling of DNA in mouse tissues confirmed the stability of hmC in vivo and demonstrated a relationship between global levels of hmC and cell proliferation. These insights have important implications for understanding the states of chemically modified DNA bases in health and disease.

  18. Hospital Medicine Resident Training Tracks: Developing the Hospital Medicine Pipeline.

    Science.gov (United States)

    Sweigart, Joseph R; Tad-Y, Darlene; Kneeland, Patrick; Williams, Mark V; Glasheen, Jeffrey J

    2017-03-01

    Hospital medicine (HM) is rapidly evolving into new clinical and nonclinical roles. Traditional internal medicine (IM) residency training likely does not optimally prepare residents for success in HM. Hospital medicine residency training tracks may offer a preferred method for specialized HM education. Internet searches and professional networks were used to identify HM training tracks. Information was gathered from program websites and discussions with track directors. The 11 HM tracks at academic medical centers across the United States focus mostly on senior residents. Track structure and curricular content are determined largely by the structure and curricula of the IM residency programs in which they exist. Almost all tracks feature experiential quality improvement projects. Content on healthcare economics and value is common, and numerous track leaders report this content is expanding from HM tracks into entire residency programs. Tracks also provide opportunities for scholarship and professional development, such as workshops on abstract creation and job procurement skills. Almost all tracks include HM preceptorships as well as rotations within various disciplines of HM. HM residency training tracks focus largely on quality improvement, health care economics, and professional development. The structures and curricula of these tracks are tightly linked to opportunities within IM residency programs. As HM continues to evolve, these tracks likely will expand to bridge clinical and extra-clinical gaps between traditional IM training and contemporary HM practice. Journal of Hospital Medicine 2017;12:173-176. © 2017 Society of Hospital Medicine

  19. Micellar effect on metal-ligand complexes of Co(II, Ni(II, Cu(II and Zn(II with citric acid

    Directory of Open Access Journals (Sweden)

    Nageswara Rao Gollapalli

    2009-12-01

    Full Text Available Chemical speciation of citric acid complexes of Co(II, Ni(II, Cu(II and Zn(II was investigated pH-metrically in 0.0-2.5% anionic, cationic and neutral micellar media. The primary alkalimetric data were pruned with SCPHD program. The existence of different binary species was established from modeling studies using the computer program MINIQUAD75. Alkalimetric titrations were carried out in different relative concentrations (M:L:X = 1:2:5, 1:3:5, 1:5:3 of metal (M to citric acid. The selection of best chemical models was based on statistical parameters and residual analysis. The species detected were MLH, ML2, ML2H and ML2H2. The trend in variation of stability constants with change in mole fraction of the medium is explained on the basis of electrostatic and non-electrostatic forces. Distributions of the species with pH at different compositions of micellar media are also presented.

  20. Complexes of Cu(II), Ni(II), Co(II), oxovanadium(IV) and dioxouranium(VI) with N,N'-ethylenebis (2-hydroxy-4-methylpropiophenoneimine)

    International Nuclear Information System (INIS)

    Patel, M.M.; Patel, M.R.; Patel, M.N.; Patel, R.P.

    1982-01-01

    Complexes of Cu(II), Ni(II), Co(II), oxovanadium(IV) and dioxouranium(VI) with the schiff base, N,N'-ethylenebis(2-hydroxy-4-methylpropiophenoneimine)(4-MeOHPEN), have been synthesised and characterised on the basis of elemental analyses, conductivity, magnetic moment, electronic and infrared spectral data. Square-planar structures are suggested for Cu(II), Ni(II) and Co(II) complexes while a distorted square-pyramidal structure is suggested for the oxovanadium(IV) complex. (author)

  1. Elaboration of a Highly Porous RuII,II Analogue of HKUST-1.

    Science.gov (United States)

    Zhang, Wenhua; Freitag, Kerstin; Wannapaiboon, Suttipong; Schneider, Christian; Epp, Konstantin; Kieslich, Gregor; Fischer, Roland A

    2016-12-19

    When the dinuclear Ru II,II precursor [Ru 2 (OOCCH 3 ) 4 ] is employed under redox-inert conditions, a Ru II,II analogue of HKUST-1 was successfully prepared and characterized as a phase-pure microcrystalline powder. X-ray absorption near-edge spectroscopy confirms the oxidation state of the Ru centers of the paddle-wheel nodes in the framework. The porosity of 1371 m 2 /mmol of Ru II,II -HKUST-1 exceeds that of the parent compound HKUST1 (1049 m 2 / mmol).

  2. Dynamic adsorption of mixtures of Rhodamine B, Pb (II), Cu (II) and Zn(II) ions on composites chitosan-silica-polyethylene glycol membrane

    Science.gov (United States)

    Mahatmanti, F. W.; Rengga, W. D. P.; Kusumastuti, E.; Nuryono

    2018-04-01

    The adsorption of a solution mixture of Rhodamine B, Pb (II), Cu (II) and Zn(II) was studied using dynamic methods employing chitosan-silica-polyethylene glycol (Ch/Si/P) composite membrane as an adsorptive membrane. The composite Ch/Si/P membrane was prepared by mixing a chitosan-based membrane with silica isolated from rice husk ash (ASP) and polyethylene glycol (PEG) as a plasticizer. The resultant composite membrane was a stronger and more flexible membrane than the original chitosan-based membrane as indicated by the maximum percentage of elongation (20.5 %) and minimum Young’s Modulus (80.5 MPa). The composite membrane also showed increased mechanical and hydrophilic properties compared to the chitosan membranes. The membrane was used as adsorption membrane for Pb (II), Cu (II), Cd (II) ions and Rhodamine B dyes in a dynamic system where the permeation and selectivity were determined. The permeation of the components was observed to be in the following order: Rhodamine B > Cd (II) > Pb (II) > Cu (II) whereas the selectivity was shown to decrease the order of Cu (II) > Pb (II) > Cd (II) > Rhodamine B.

  3. Multidrug Resistant Pseudomonas Mycotic Pseudoaneurysm following Cardiac Transplant Bridged by Ventricular Assistant Device

    Directory of Open Access Journals (Sweden)

    C. Aye

    2017-01-01

    Full Text Available Mycotic pseudoaneurysm of aorta following cardiac surgery is rare but is highly fatal if it is unrecognized and untreated. Here, we report a case of a 45-year-old male patient who presented with rapidly progressive multiple pseudoaneurysms of the ascending aorta infected with multidrug resistant (MDR Pseudomonas aeruginosa at 5 weeks after cardiac transplantation, on a background of prior bridging therapy with left ventricular assistant device (LVAD. The patient was successfully treated with the newer cephalosporin, Ceftolozane/Tazobactam, in combination with surgery. This is the first reported case of mycotic pseudoaneurysm infected with MDR Pseudomonas. This case also highlights the importance of high vigilance and timely multimodality treatment in the diagnosis and management of mycotic pseudoaneurysm following cardiac transplant, especially in patients who had LVAD.

  4. Automatic remote monitoring utilizing daily transmissions: transmission reliability and implantable cardioverter defibrillator battery longevity in the TRUST trial.

    Science.gov (United States)

    Varma, Niraj; Love, Charles J; Schweikert, Robert; Moll, Philip; Michalski, Justin; Epstein, Andrew E

    2018-04-01

    Benefits of automatic remote home monitoring (HM) among implantable cardioverter defibrillator (ICD) patients may require high transmission frequency. However, transmission reliability and effects on battery longevity remain uncertain. We hypothesized that HM would have high transmission success permitting punctual guideline based follow-up, and improve battery longevity. This was tested in the prospective randomized TRUST trial. Implantable cardioverter defibrillator patients were randomized post-implant 2:1 to HM (n = 908) (transmit daily) or to Conventional in-person monitoring [conventional management (CM), n = 431 (HM disabled)]. In both groups, five evaluations were scheduled every 3 months for 15 months. Home Monitoring technology performance was assessed by transmissions received vs. total possible, and number of scheduled HM checks failing because of missed transmissions. Battery longevity was compared in HM vs. CM at 15 months, and again in HM 3 years post-implant using continuously transmitted data. Transmission success per patient was 91% (median follow-up of 434 days). Overall, daily HM transmissions were received in 315 795 of a potential 363 450 days (87%). Only 55/3759 (1.46%) of unsuccessful scheduled evaluations in HM were attributed to transmission loss. Shock frequency and pacing percentage were similar in HM vs. CM. Fifteen month battery longevity was 12% greater in HM (93.2 ± 8.8% vs. 83.5 ± 6.0% CM, P battery longevity was 50.9 ± 9.1% (median 52%) at 36 months. Automatic remote HM demonstrated robust transmission reliability. Daily transmission load may be sustained without reducing battery longevity. Home Monitoring conserves battery longevity and tracks long term device performance. ClinicalTrials.gov; NCT00336284.

  5. Systematic Review on the Efficacy and Safety of Herbal Medicines for Vascular Dementia

    Directory of Open Access Journals (Sweden)

    Sui Cheung Man

    2012-01-01

    Full Text Available We present a systematic review of existing research that aims to assess the efficacy and safety of herbal medications (HM, as either monotherapy or adjunct to orthodox medications (OM, mainly comprised of cholinesterase inhibitors, for vascular dementia (VaD. We included 47 studies conducted in mainland China, each testing different HM. Of 43 HM monotherapy studies, 37 reported HM to be significantly better than OM or placebo; six reported similar efficacy between HM and OM. All four HM adjuvant studies reported significant efficacy. No major adverse events for HM were reported. Heterogeneity in diagnostic criteria, interventions and outcome measures hindered comprehensive data analysis. Studies suggested that HM can be a safe and effective treatment for VaD, either alone or in conjunction with OM. However, methodological flaws in the design of the studies limited the extent to which the results could be interpreted. Thirty most commonly used herbal constituents, including Rhizoma Chuanxiong (Chuanxiong in Chinese, Radix Polygoni Multiflori (Heshouwu in Chinese and Radix Astragali (Huangqi in Chinese. were ranked. Further multi-center trials with large sample sizes, high methodological quality and standardized HM ingredients are necessary for clinical recommendations to be made.

  6. Serum insulin-like growth factor II (IGF-II) in chronic heart failure

    International Nuclear Information System (INIS)

    Tong Lijun; Chen Donghai; Ji Naijun; Fan Bifu; Wang Chengyao; Mei Yibin; Li Fuyuan; Kao Yan

    2004-01-01

    Objective: To investigate the clinical significance of changes of serum insulin-like growth factor II (IGF-II) levels in patients with chronic heart failure. Methods: Serum IGF-II levels were measured with RIA in 132 cases of chronic heart failure and 45 controls. Results: Serum IGF-II levels were significantly higher in patients with chronic heart failure than those in the controls (t=0.033, P<0.001). IGF-II levels were highest in grade IV CHF patients (vs grade II t=3.963, P<0.01; vs grade III, t=3.578, P<0.01). In the twelve patients died in hospital, the serum IGF-II levels were significantly higher than those patients recovered (t=7.141, P<0.01). Conclusion: Serum IGF-II levels were increased in CHF patients and were highest in the most severe cases. (authors)

  7. Observations and predictions of wave runup, extreme water levels, and medium-term dune erosion during storm conditions

    OpenAIRE

    Suanez , Serge ,; Cancouët , Romain; Floc'h , France; Blaise , Emmanuel; Ardhuin , Fabrice; Filipot , Jean-François; Cariolet , Jean-Marie; Delacourt , Christophe

    2015-01-01

    Monitoring of dune erosion and accretion on the high-energy macrotidal Vougot beach in North Brittany (France) over the past decade (2004–2014) has revealed significant morphological changes. Dune toe erosion/accretion records have been compared with extreme water level measurements, defined as the sum of (i) astronomic tide; (ii) storm surge; and (iii) vertical wave runup. Runup parameterization was conducted using swash limits, beach profiles, and hydrodynamic (Hm0, Tm0,–1, and high tide wa...

  8. Performance-oriented packagings for hazardous materials: Resource guide

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    This document provides recommendations to US Department of Energy (DOE) shippers regarding packaging that meet performance-oriented packaging requirements implemented by US Department of Transportation (DOT) in rulemaking HM-181 (December 21, 1990) and subsequent actions. The packaging described in this document are certified by their vendor to comply with requirements for Packing Group I, II, or III hazardous materials packaging. The intent of this document is to share information between DOE and contractors and at all DOE facilities.

  9. Performance-oriented packagings for hazardous materials: Resource guide

    International Nuclear Information System (INIS)

    1993-09-01

    This document provides recommendations to US Department of Energy (DOE) shippers regarding packaging that meet performance-oriented packaging requirements implemented by US Department of Transportation (DOT) in rulemaking HM-181 (December 21, 1990) and subsequent actions. The packaging described in this document are certified by their vendor to comply with requirements for Packing Group I, II, or III hazardous materials packaging. The intent of this document is to share information between DOE and contractors and at all DOE facilities

  10. Hipertermia maligna no Brasil: análise da atividade do hotline em 2009

    Directory of Open Access Journals (Sweden)

    Helga Cristina Almeida da Silva

    2013-02-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: Hipertermia maligna (HM é doença farmacogenética, com reação hipermetabólica anormal a anestésicos halogenados e/ou relaxantes musculares despolarizantes. Desde 1991 há um serviço hotline de atendimento telefônico para HM no Brasil, disponível 24 horas por dia, em São Paulo. Este artigo analisa a atividade do serviço brasileiro de hotline para HM em 2009. MÉTODOS: Análise prospectiva de todas chamadas telefônicas paria maligna (HM é doença farmacogenética, com reação hipermetabólica anormal a anestésicos halogenados e/ou relaxantes musculares despolarizantes. Desde 1991 há um serviço hotline de atendimento telefônico para HM no Brasil, disponível 24 horas por dia, em São Paulo. Este art go analisa a at vidade do serviço brasileiro de hotline para HM em 2009a o serviço brasileiro de hotline para HM, de janeiro a dezembro de 2009. RESULTADOS: Foram recebidas 22 ligações; 21 provenientes do Sul-Sudeste do Brasil e uma do Norte. Quinze eram pedidos de informações gerais sobre HM. Sete foram suspeitas de crises agudas de HM, das quais duas não foram consideradas como HM. Nas cinco crises compatíveis com HM, todos os pacientes receberam anestésicos inalatórios halogenados (2 isoflurano, 3 sevoflurano e um usou também succinilcolina; havia quatro homens e uma mulher, com média de idade de 18 anos (2-27. Problemas descritos nas cinco crises de HM: taquicardia (cinco, aumento do gás carbônico expirado (quatro, hipertermia (três, acidemia (um, rabdomiólise (um e mioglobinúria (um. Um paciente recebeu dantrolene. Todos os cinco pacientes com crises de HM foram seguidos em unidade de terapia intensiva e recuperaram-se sem sequelas. A suscetibilidade à HM foi posteriormente confirmada em dois pacientes por meio do teste de contratura muscular in vitro. CONCLUSÕES: O número de chamadas por ano no serviço brasileiro de hotline para HM ainda é reduzido. As características das crises

  11. The interactive influence of water chemistry and nanoparticle characteristics in determining the environmental fate of metal-based nanoparticles: a case of nAg and nZnO

    CSIR Research Space (South Africa)

    Thwala, M

    2014-09-01

    Full Text Available . The NP concentration (number/mL) in 100HM remained relatively higher than in 50HM, more so for nAg. Such an observation suggested a stabilising effect in high ionic strength (IS) 100HM, such an effect was confirmed by lower dissolution in 100HM relative...

  12. Ni(II, Pd(II and Pt(II complexes with ligand containing thiosemicarbazone and semicarbazone moiety: synthesis, characterization and biological investigation

    Directory of Open Access Journals (Sweden)

    SULEKH CHANDRA

    2008-07-01

    Full Text Available The synthesis of nickel(II, palladium(II and platinum(II complexes with thiosemicarbazone and semicarbazone of p-tolualdehyde are reported. All the new compounds were characterized by elemental analysis, molar conductance measurements, magnetic susceptibility measurements, mass, 1H-NMR, IR and electronic spectral studies. Based on the molar conductance measurements in DMSO, the complexes may be formulated as [Ni(L2Cl2] and [M(L2]Cl2 (where M = Pd(II and Pt(II due to their non-electrolytic and 1:2 electrolytic nature, respectively. The spectral data are consistent with an octahedral geometry around Ni(II and a square planar geometry for Pd(II and Pt(II, in which the ligands act as bidentate chelating agents, coordinated through the nitrogen and sulphur/oxygen atoms. The ligands and their metal complexes were screened in vitro against fungal species Alternaria alternata, Aspergillus niger and Fusarium odum, using the food poison technique.

  13. A feasibility test to estimate the duration of phytoextraction of heavy metals from polluted soils.

    Science.gov (United States)

    Japenga, J; Koopmans, G F; Song, J; Römkens, P F A M

    2007-01-01

    The practical applicability of heavy metal (HM) phytoextraction depends heavily on its duration. Phytoextraction duration is the main cost factorfor phytoextraction, both referring to recurring economic costs during phytoextraction and to the cost of the soil having no economic value during phytoextraction. An experiment is described here, which is meant as a preliminary feasibility test before starting a phytoextraction scheme in practice, to obtain a more realistic estimate of the phytoextraction duration of a specific HM-polluted soil. In the experiment, HM-polluted soil is mixed at different ratios with unpolluted soil of comparable composition to mimic the gradual decrease of the HM content in the target HM-polluted soil during phytoextraction. After equilibrating the soil mixtures, one cropping cycle is carried out with the plant species of interest. At harvest, the adsorbed HM contents in the soil and the HM contents in the plant shoots are determined. The adsorbed HM contents in the soil are then related to the HM contents in the plant shoots by a log-log linear relationship that can then be used to estimate the phytoextraction duration of a specific HM-polluted soil. This article describes and evaluates the merits of such a feasibility experiment. Potential drawbacks regarding the accuracy of the described approach are discussed and a greenhouse-field extrapolation procedure is proposed.

  14. Genotypic and environmental variation in cadmium, chromium, lead and copper in rice and approaches for reducing the accumulation

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Fangbin; Wang, Runfeng [Institute of Crop Science, Department of Agronomy, College of Agriculture and Biotechnology, Zijingang Campus, Zhejiang University, Hangzhou 310058 (China); Cheng, Wangda [Jiaxing Academy of Agricultural Sciences, Jiaxing 314016 (China); Zeng, Fanrong; Ahmed, Imrul Mosaddek; Hu, Xinna; Zhang, Guoping [Institute of Crop Science, Department of Agronomy, College of Agriculture and Biotechnology, Zijingang Campus, Zhejiang University, Hangzhou 310058 (China); Wu, Feibo, E-mail: wufeibo@zju.edu.cn [Institute of Crop Science, Department of Agronomy, College of Agriculture and Biotechnology, Zijingang Campus, Zhejiang University, Hangzhou 310058 (China)

    2014-10-15

    The field scale trials revealed significant genotypic and environmental differences in grain heavy metal (HM) concentrations of 158 newly developed rice varieties grown in twelve locations of Zhejiang province of China. Grain Pb and Cd contents in 5.3% and 0.4% samples, respectively, were above the maximum permissible concentration (MPC); none of samples had Cr/Cu exceeding MPC. Stepwise multiple linear regression analysis estimated soil HM critical levels for safe rice production. Low grain HM accumulation cultivars such as Xiushui817, Jiayou08-1 and Chunyou689 were recommended as suitable cultivars for planting in slight/medium HM contaminated soils. The alleviating regulator (AR) of (NH{sub 4}){sub 2}SO{sub 4} as N fertilizer coupled with foliar spray of a mixture containing glutathione (GSH), Si, Zn and Se significantly decreased grain Cd, Cr, Cu and Pb concentrations grown in HM contaminated fields with no effect on yield, indicating a promising measurement for further reducing grain HM content to guarantee safe food production. - Highlights: • Field trials evaluated situation of grain HM in main rice growing areas of Zhejiang. • Forecasting index system to predict rice grain HM concentration was achieved. • Hybrid rice holds higher grain Cd concentration than conventional cultivars. • Low grain HM accumulation rice cultivars were successfully identified. • Developed alleviating regulator which effectively reduced grain toxic HM.

  15. Genotypic and environmental variation in cadmium, chromium, lead and copper in rice and approaches for reducing the accumulation

    International Nuclear Information System (INIS)

    Cao, Fangbin; Wang, Runfeng; Cheng, Wangda; Zeng, Fanrong; Ahmed, Imrul Mosaddek; Hu, Xinna; Zhang, Guoping; Wu, Feibo

    2014-01-01

    The field scale trials revealed significant genotypic and environmental differences in grain heavy metal (HM) concentrations of 158 newly developed rice varieties grown in twelve locations of Zhejiang province of China. Grain Pb and Cd contents in 5.3% and 0.4% samples, respectively, were above the maximum permissible concentration (MPC); none of samples had Cr/Cu exceeding MPC. Stepwise multiple linear regression analysis estimated soil HM critical levels for safe rice production. Low grain HM accumulation cultivars such as Xiushui817, Jiayou08-1 and Chunyou689 were recommended as suitable cultivars for planting in slight/medium HM contaminated soils. The alleviating regulator (AR) of (NH 4 ) 2 SO 4 as N fertilizer coupled with foliar spray of a mixture containing glutathione (GSH), Si, Zn and Se significantly decreased grain Cd, Cr, Cu and Pb concentrations grown in HM contaminated fields with no effect on yield, indicating a promising measurement for further reducing grain HM content to guarantee safe food production. - Highlights: • Field trials evaluated situation of grain HM in main rice growing areas of Zhejiang. • Forecasting index system to predict rice grain HM concentration was achieved. • Hybrid rice holds higher grain Cd concentration than conventional cultivars. • Low grain HM accumulation rice cultivars were successfully identified. • Developed alleviating regulator which effectively reduced grain toxic HM

  16. Anti-inflammatory drugs interacting with Zn(II), Cd(II) and Pt(II) metal ions.

    Science.gov (United States)

    Dendrinou-Samara, C; Tsotsou, G; Ekateriniadou, L V; Kortsaris, A H; Raptopoulou, C P; Terzis, A; Kyriakidis, D A; Kessissoglou, D P

    1998-09-01

    Complexes of Zn(II), Cd(II) and Pt(II) metal ions with the anti-inflammatory drugs, 1-methyl-5-(p-toluoyl)-1H-pyrrole-2-acetic acid (Tolmetin), alpha-methyl-4-(2-methylpropyl)benzeneacetic acid (Ibuprofen), 6-methoxy-alpha-methylnaphthalene-2-acetic acid (Naproxen) and 1-(4-chlorobenzoyl)-5-methoxy-2-methyl-1H-indole-3-acetic acid (indomethacin) have been synthesized and characterized. In the structurally characterized Cd(naproxen)2 complex the anti-inflammatory drugs acts as bidentate chelate ligand coordinatively bound to metal ions through the deprotonated carboxylate group. Crystal data for 1: [C32H26O8Cd], orthorhombic, space group P22(1)2(1), a = 5.693(2) (A), b = 8.760(3) (A), c = 30.74(1) (A), V = 1533(1) A3, Z = 2. Antibacterial and growth inhibitory activity is higher than that of the parent ligands or the platinum(II) diamine compounds.

  17. Synthesis, spectroscopic and antimicrobial properties of Co(II), Ni (II ...

    African Journals Online (AJOL)

    The objective of this study is to investigate the antimicrobial activity of novel Schiff base metal complexes. The resistance of micro-organisms to classical antimicrobial compounds poses a challenge to effective management and treatment of some diseases. In line with this, copper (II), nickel (II) and cobalt (II) complexes of ...

  18. Synergistic effect of carbon nanotube as sintering aid and toughening agent in spark plasma sintered molybdenum disilicide-hafnium carbide composite

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, Biswajyoti; Asiq Rahman, O.S.; Sribalaji, M [Materials Science and Engineering, Indian Institute of Technology Patna, Bihta Kanpa Road, Bihta, Patna, Bihar 801103 (India); Bakshi, Srinivasa Rao [Department of Metallurgical and Materials Engineering, Indian Institute of Technology Madras, Chennai 600036 (India); Keshri, Anup Kumar, E-mail: anup@iitp.ac.in [Materials Science and Engineering, Indian Institute of Technology Patna, Bihta Kanpa Road, Bihta, Patna, Bihar 801103 (India)

    2016-12-15

    Hafnium carbide (HfC) along with sintering aids was consolidated at a relatively lower temperature i.e. 1600 °C (i.e. T=~0.41 T{sub m}) under a uniaxial load of 50 MPa by spark plasma sintering. Two different sintering aids such as molybdenum disilicide (MoSi{sub 2}) and carbon nanotube (CNT) were added to enhance the densification and lower the extent of grain growth in the sintered pellets. Density of the sintered pellet increased from 96.0±0.8% in HfC +5 wt% MoSi{sub 2} (HM) to 99.0±0.5% with the addition of 2 wt% CNT in HfC+5 wt% MoSi{sub 2} (HMC) at sintering temperature of 1600 °C. Further, the extent of grain growth drastically reduced from 204% in HM to 50% in HMC. Analysis of linear shrinkage during densification revealed that CNT addition increased densification rate and decreased the time required to reach the density of 99.0±0.5% at 1600 °C. Increased densification and lower degree of grain growth could be due to the synergistic effect offered by the CNT, which are as follows: (i) Lubrication effect of CNT, (ii) Lower activation energy for grain boundary diffusion (iii) Reduction in liquid phase sintering temperature and (iv) Grain boundary pinning. Fracture toughness of the sintered HM and HMC composite was obtained using indentation technique. By the addition of 2 wt% CNT in HM, drastic increase of 91% in fracture toughness was seen. This significant improvement in fracture toughness was due to the enhanced densification and relatively lower grain size of HMC. Also crack bridging, crack deflection, crack arrest, CNT and graphene sheet pull-out and swording played major role in toughening of HMC pellet.

  19. RTNS-II [Rotating Target Neutron Source II] operational summary

    International Nuclear Information System (INIS)

    Heikkinen, D.W.

    1988-09-01

    The Rotating Target Neutron Source II facility (RTNS-II) operated for over nine years. Its purpose was to provide high intensities of 14 MeV neutrons for materials studies in the fusion energy program. For the period from 1982-1987, the facility was supported by both the US (Department of Energy) and Japan (Ministry of Education, Culture, and Science). RTNS-II contains two accelerator-based neutron sources which use the T(d,n) 4 He reaction. In this paper, we will summarize the operational history of RTNS-II. Typical operating parameters are given. In addition, a brief description of the experimental program is presented. The current status and future options for the facility are discussed. 7 refs., 5 tabs

  20. Breast milk nutrient content and infancy growth.

    Science.gov (United States)

    Prentice, Philippa; Ong, Ken K; Schoemaker, Marieke H; van Tol, Eric A F; Vervoort, Jacques; Hughes, Ieuan A; Acerini, Carlo L; Dunger, David B

    2016-06-01

    Benefits of human breast milk (HM) in avoiding rapid infancy weight gain and later obesity could relate to its nutrient content. We tested the hypothesis that differential HM total calorie content (TCC) or macronutrient contents may be associated with infancy growth. HM hindmilk samples were collected at ages 4-8 weeks from 614 mothers participating in a representative birth cohort, with repeated infancy anthropometry. HM triglyceride (fat), lipid analytes and lactose (carbohydrate) were measured by (1) H-NMR, and protein content by the Dumas method. TCC and %macronutrients were determined. In 614 HM samples, fat content was as follows: [median(IQR)]: 2.6 (1.7-3.6) g/100 mL, carbohydrate: 8.6 (8.2-8.8) g/100 mL, protein: 1.2 (1.1-1.2) g/100 mL; TCC: 61.8 (53.7-71.3) kcal/100 mL. HM of mothers exclusively breast feeding vs. mixed feeding was more calorific with higher %fat, lower %carbohydrate and lower %protein. Higher HM TCC was associated with lower 12-months body mass index (BMI)/adiposity, and lower 3-12 months gains in weight/BMI. HM %fat was inversely related to 3-12 months gains in weight, BMI and adiposity, whereas %carbohydrate was positively related to these measures. HM %protein was positively related to 12-months BMI. HM analysis showed wide variation in %macronutrients. Although data on milk intakes were unavailable, our findings suggest functional relevance of HM milk composition to infant growth. ©2016 The Authors. Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica.